Sample records for endoscopes

  1. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  2. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  3. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  4. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  5. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  6. Automated high-level disinfection of nonchanneled flexible endoscopes: duty cycles and endoscope repair.

    PubMed

    Statham, Melissa McCarty; Willging, J Paul

    2010-10-01

    Guidelines issued by the Association of Operating Room Nurses and the Association of Professionals in Infection Control and Epidemiology recommend high-level disinfection (HLD) for semicritical instruments, such as flexible endoscopes. We aim to examine the durability of endoscopes to continued use and automated HLD. We report the number of duty cycles a flexible endoscope can withstand before repairs should be anticipated. Retrospective review. A total of 4,336 endoscopic exams and subsequent disinfection cycles were performed with 60 flexible endoscopes in an outpatient tertiary pediatric otolaryngology practice from 2005 to 2009. All endoscopes were systemically cleaned with mechanical cleansing followed by leak testing, enzymatic cleaning, and exposure to Orthophthaldehyde (0.55%) for 5 minutes at a temperature of at least 25°C, followed by rinsing for 3 minutes. A total of 77 repairs were performed, 48 major (average cost $3,815.97), and 29 minor (average cost $326.85). On average, the 2.2-mm flexible endoscopes were utilized for 61.9 examinations before major repair was needed, whereas the 3.6 mm endoscopes were utilized for 154.5 exams before needing minor repairs. No major repairs have been needed to date on the 3.6-mm endoscopes. Automated endoscope reprocessor use for HLD is an effective means to disinfect and process flexible endoscopes. This minimizes variability in the processing of the endoscopes and maximizes the rate of successful HLD. Even when utilizing standardized, automated HLD and limiting the number of personnel processing the endoscopes, smaller fiberoptic endoscopes demonstrate a shortened time interval between repairs than that seen with the larger endoscopes. Laryngoscope, 2010.

  7. The Clinical Accuracy of Endoscopic Ultrasonography and White Light Imaging in Gastric Endoscopic Submucosal Dissection

    PubMed Central

    Park, Soon Hong; Sung, Sang Hun; Lee, Seung Jun; Jung, Min Kyu; Kim, Sung Kook

    2012-01-01

    Purpose Gastric mucosal neoplastic lesions should have characteristic endoscopic features for successful endoscopic submucosal dissection. Materials and Methods Out of the 1,010 endoscopic submucosal dissection, we enrolled 62 patients that had the procedure cancelled. Retrospectively, whether the reasons for cancelling the endoscopic submucosal dissection were consistent with the indications for an endoscopic submucosal dissection were assessed by analyzing the clinical outcomes of the patients that had the surgery. Results The cases were divided into two groups; the under-diagnosed group (30 cases; unable to perform an endoscopic submucosal dissection) and the over-diagnosed group (32 cases; unnecessary to perform an endoscopic submucosal dissection), according to the second endoscopic findings, compared with the index conventional white light image. There were six cases in the under-diagnosed group with advanced gastric cancer on the second conventional white light image endoscopy, 17 cases with submucosal invasion on endoscopic ultrasonography findings, 5 cases with a size greater than 3 cm and ulcer, 1 case with diffuse infiltrative endoscopic features, and 1 case with lymph node involvement on computed tomography. A total of 25 patients underwent a gastrectomy to remove a gastric adenocarcinoma. The overall accuracy of the decision to cancel the endoscopic submucosal dissection was 40% (10/25) in the subgroup that had the surgery. Conclusions The accuracy of the decision to cancel the endoscopic submucosal dissection, after conventional white light image and endoscopic ultrasonography, was low in this study. Other diagnostic options are needed to arrive at an accurate decision on whether to perform a gastric endoscopic submucosal dissection. PMID:22792522

  8. Endoscope field of view measurement.

    PubMed

    Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen

    2017-03-01

    The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOV WS method) in the current ISO 8600-3 standard and proposed a new method (the FOV EP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOV EP method was more accurate than the FOV WS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard.

  9. Endoscope field of view measurement

    PubMed Central

    Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen

    2017-01-01

    The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOVWS method) in the current ISO 8600-3 standard and proposed a new method (the FOVEP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOVEP method was more accurate than the FOVWS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard. PMID:28663840

  10. Novel Concept of Attaching Endoscope Holder to Microscope for Two Handed Endoscopic Tympanoplasty.

    PubMed

    Khan, Mubarak M; Parab, Sapna R

    2016-06-01

    The well established techniques in tympanoplasty are routinely performed with operating microscopes for many decades now. Endoscopic ear surgeries provide minimally invasive approach to the middle ear and evolving new science in the field of otology. The disadvantage of endoscopic ear surgeries is that it is one-handed surgical technique as the non-dominant left hand of the surgeon is utilized for holding and manipulating the endoscope. This necessitated the need for development of the endoscope holder which would allow both hands of surgeon to be free for surgical manipulation and also allow alternate use of microscope during tympanoplasty. To report the preliminary utility of our designed and developed endoscope holder attachment gripping to microscope for two handed technique of endoscopic tympanoplasty. Prospective Non Randomized Clinical Study. Our endoscope holder attachment for microscope was designed and developed to aid in endoscopic ear surgery and to overcome the disadvantage of single handed endoscopic surgery. It was tested for endoscopic Tympanoplasty. The design of the endoscope holder attachment is described in detail along with its manipulation and manoeuvreing. A total of 78 endoholder assisted type 1 endoscopic cartilage tympanoplasties were operated to evaluate its feasibility for the two handed technique and to evaluate the results of endoscopic type 1 cartilage tympanoplasty. In early follow up period ranging from 6 to 20 months, the graft uptake was seen in 76 ears with one residual perforation and 1 recurrent perforations giving a success rate of 97.435 %. Our endocsope holder attachment for gripping microscope is a good option for two handed technique in endoscopic type 1 cartilage tympanoplasty. The study reports the successful application and use of our endoscope holder attachment for gripping microscope in two handed technique of endoscopic type 1 cartilage tympanoplasty and comparable results with microscopic techniques. IV.

  11. Smartphone-Based Endoscope System for Advanced Point-of-Care Diagnostics: Feasibility Study

    PubMed Central

    Bae, Jung Kweon; Vavilin, Andrey; You, Joon S; Kim, Hyeongeun; Ryu, Seon Young; Jang, Jeong Hun

    2017-01-01

    Background Endoscopic technique is often applied for the diagnosis of diseases affecting internal organs and image-guidance of surgical procedures. Although the endoscope has become an indispensable tool in the clinic, its utility has been limited to medical offices or operating rooms because of the large size of its ancillary devices. In addition, the basic design and imaging capability of the system have remained relatively unchanged for decades. Objective The objective of this study was to develop a smartphone-based endoscope system capable of advanced endoscopic functionalities in a compact size and at an affordable cost and to demonstrate its feasibility of point-of-care through human subject imaging. Methods We developed and designed to set up a smartphone-based endoscope system, incorporating a portable light source, relay-lens, custom adapter, and homebuilt Android app. We attached three different types of existing rigid or flexible endoscopic probes to our system and captured the endoscopic images using the homebuilt app. Both smartphone-based endoscope system and commercialized clinical endoscope system were utilized to compare the imaging quality and performance. Connecting the head-mounted display (HMD) wirelessly, the smartphone-based endoscope system could superimpose an endoscopic image to real-world view. Results A total of 15 volunteers who were accepted into our study were captured using our smartphone-based endoscope system, as well as the commercialized clinical endoscope system. It was found that the imaging performance of our device had acceptable quality compared with that of the conventional endoscope system in the clinical setting. In addition, images captured from the HMD used in the smartphone-based endoscope system improved eye-hand coordination between the manipulating site and the smartphone screen, which in turn reduced spatial disorientation. Conclusions The performance of our endoscope system was evaluated against a commercial system in routine otolaryngology examinations. We also demonstrated and evaluated the feasibility of conducting endoscopic procedures through a custom HMD. PMID:28751302

  12. Is side-viewing endoscope assisted balloon dilatation better for corrosive gastric outlet obstruction?

    PubMed

    Katiyar, Prashant; Nijhawan, Sandeep; Saradava, Vimal; Nagaich, Neeraj; Gupta, Gaurav; Mathur, Amit; Nepalia, Subhash

    2013-11-01

    Endoscopic balloon dilatation (EBD) is an effective therapy for caustic-induced gastric outlet obstruction (GOO). Gaining access to the stricture site is the most important step. It is sometimes difficult to negotiate a balloon through the stricture with a front-viewing endoscope due to deformed anatomy of stomach. To overcome this technical difficulty, a side-viewing endoscope can be used. There is limited data regarding the use of side-viewing endoscopes in EBD. We here report on the short-term efficacy and safety of EBD in caustic-induced GOO. In technically difficult cases, a side-viewing endoscope was used for EBD and its efficacy and safety were assessed. The study included 25 patients with caustic-induced GOO. Patients underwent EBD using a through-the-scope balloon. Initial balloon dilatation was performed with a front-viewing endoscope. A side-viewing endoscope was used where negotiation across the stricture failed with a front-viewing endoscope. Dilatation was started at 8 mm diameter and was performed at 1-week intervals. The end point of dilatation was 15 mm diameter. In 18 patients successful balloon dilatation was possible with a front-viewing endoscope. A side-viewing endoscope was used in six patients as negotiation across the stricture was not possible with a front-viewing endoscope. In all six patients negotiation across the stricture followed by successful dilatation was successful with a side-viewing endoscope. Of the 25 patients included in this study, 24 (96%) achieved procedural success (18 with a front-viewing endoscope and 6 with a side-viewing endoscope) in 3-9 sessions. Our results show that EBD is a safe and effective option for caustic-induced GOO and in difficult cases a side-viewing endoscope can be used to achieve technical success.

  13. Potential capacity of endoscopic screening for gastric cancer in Japan.

    PubMed

    Hamashima, Chisato; Goto, Rei

    2017-01-01

    In 2016, the Japanese government decided to introduce endoscopic screening for gastric cancer as a national program. To provide endoscopic screening nationwide, we estimated the proportion of increase in the number of endoscopic examinations with the introduction of endoscopic screening, based on a national survey. The total number of endoscopic examinations has increased, particularly in clinics. Based on the national survey, the total number of participants in gastric cancer screening was 3 784 967. If 30% of the participants are switched from radiographic screening to endoscopic screening, approximately 1 million additional endoscopic examinations are needed. In Japan, the participation rates in gastric cancer screening and the number of hospitals and clinics offering upper gastrointestinal endoscopy vary among the 47 prefectures. If the participation rates are high and the numbers of hospitals and clinics are small, the proportion of increase becomes larger. Based on the same assumption, 50% of big cities can provide endoscopic screening with a 5% increase in the total number of endoscopic examinations. However, 16.7% of the medical districts are available for endoscopic screening within a 5% increase in the total number of endoscopic examinations. Despite the Japanese government's decision to introduce endoscopic screening for gastric cancer nationwide, its immediate introduction remains difficult because of insufficient medical resources in rural areas. This implies that endoscopic screening will be initially introduced to big cities. To promote endoscopic screening for gastric cancer nationwide, the disparity of medical resources must first be resolved. © 2016 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  14. Advanced Endoscopic Navigation: Surgical Big Data, Methodology, and Applications.

    PubMed

    Luo, Xiongbiao; Mori, Kensaku; Peters, Terry M

    2018-06-04

    Interventional endoscopy (e.g., bronchoscopy, colonoscopy, laparoscopy, cystoscopy) is a widely performed procedure that involves either diagnosis of suspicious lesions or guidance for minimally invasive surgery in a variety of organs within the body cavity. Endoscopy may also be used to guide the introduction of certain items (e.g., stents) into the body. Endoscopic navigation systems seek to integrate big data with multimodal information (e.g., computed tomography, magnetic resonance images, endoscopic video sequences, ultrasound images, external trackers) relative to the patient's anatomy, control the movement of medical endoscopes and surgical tools, and guide the surgeon's actions during endoscopic interventions. Nevertheless, it remains challenging to realize the next generation of context-aware navigated endoscopy. This review presents a broad survey of various aspects of endoscopic navigation, particularly with respect to the development of endoscopic navigation techniques. First, we investigate big data with multimodal information involved in endoscopic navigation. Next, we focus on numerous methodologies used for endoscopic navigation. We then review different endoscopic procedures in clinical applications. Finally, we discuss novel techniques and promising directions for the development of endoscopic navigation.

  15. Robot-assisted endoscope guidance versus manual endoscope guidance in functional endonasal sinus surgery (FESS).

    PubMed

    Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten

    2017-10-01

    Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.

  16. Endoscopic root canal treatment.

    PubMed

    Moshonov, Joshua; Michaeli, Eli; Nahlieli, Oded

    2009-10-01

    To describe an innovative endoscopic technique for root canal treatment. Root canal treatment was performed on 12 patients (15 teeth), using a newly developed endoscope (Sialotechnology), which combines an endoscope, irrigation, and a surgical microinstrument channel. Endoscopic root canal treatment of all 15 teeth was successful with complete resolution of all symptoms (6-month follow-up). The novel endoscope used in this study accurately identified all microstructures and simplified root canal treatment. The endoscope may be considered for use not only for preoperative observation and diagnosis but also for active endodontic treatment.

  17. Endoscopic Rectus Abdominis and Prepubic Aponeurosis Repairs for Treatment of Athletic Pubalgia.

    PubMed

    Matsuda, Dean K; Matsuda, Nicole A; Head, Rachel; Tivorsak, Tanya

    2017-02-01

    Review of the English orthopaedic literature reveals no prior report of endoscopic repair of rectus abdominis tears and/or prepubic aponeurosis detachment. This technical report describes endoscopic reattachment of an avulsed prepubic aponeurosis and endoscopic repair of a vertical rectus abdominis tear immediately after endoscopic pubic symphysectomy for coexistent recalcitrant osteitis pubis as a single-stage outpatient surgery. Endoscopic rectus abdominis repair and prepubic aponeurosis repair are feasible surgeries that complement endoscopic pubic symphysectomy for patients with concurrent osteitis pubis and expand the less invasive options for patients with athletic pubalgia.

  18. Analysis of the color rendition of flexible endoscopes

    NASA Astrophysics Data System (ADS)

    Murphy, Edward M.; Hegarty, Francis J.; McMahon, Barry P.; Boyle, Gerard

    2003-03-01

    Endoscopes are imaging devices routinely used for the diagnosis of disease within the human digestive tract. Light is transmitted into the body cavity via incoherent fibreoptic bundles and is controlled by a light feedback system. Fibreoptic endoscopes use coherent fibreoptic bundles to provide the clinician with an image. It is also possible to couple fibreoptic endoscopes to a clip-on video camera. Video endoscopes consist of a small CCD camera, which is inserted into gastrointestinal tract, and associated image processor to convert the signal to analogue RGB video signals. Images from both types of endoscope are displayed on standard video monitors. Diagnosis is dependent upon being able to determine changes in the structure and colour of tissues and biological fluids, and therefore is dependent upon the ability of the endoscope to reproduce the colour of these tissues and fluids with fidelity. This study investigates the colour reproduction of flexible optical and video endoscopes. Fibreoptic and video endoscopes alter image colour characteristics in different ways. The colour rendition of fibreoptic endoscopes was assessed by coupling them to a video camera and applying video colorimetric techniques. These techniques were then used on video endoscopes to assess how the colour rendition of video endoscopes compared with that of optical endoscopes. In both cases results were obtained at fixed illumination settings. Video endoscopes were then assessed with varying levels of illumination. Initial results show that at constant luminance endoscopy systems introduce non-linear shifts in colour. Techniques for examining how this colour shift varies with illumination intensity were developed and both methodology and results will be presented. We conclude that more rigorous quality assurance is required to reduce colour error and are developing calibration procedures applicable to medical endoscopes.

  19. Orbital endoscopic surgery

    PubMed Central

    Selva, Dinesh

    2008-01-01

    Minimally invasive ″keyhole″ surgery performed using endoscopic visualization is increasing in popularity and is being used by almost all surgical subspecialties. Within ophthalmology, however, endoscopic surgery is not commonly performed and there is little literature on the use of the endoscope in orbital surgery. Transorbital use of the endoscope can greatly aid in visualizing orbital roof lesions and minimizing the need for bone removal. The endoscope is also useful during decompression procedures and as a teaching aid to train orbital surgeons. In this article, we review the history of endoscopic orbital surgery and provide an overview of the technique and describe situations where the endoscope can act as a useful adjunct to orbital surgery. PMID:18158397

  20. Rescue endoscopic bleeding control for nonvariceal upper gastrointestinal hemorrhage using clipping and detachable snaring.

    PubMed

    Lee, J H; Kim, B K; Seol, D C; Byun, S J; Park, K H; Sung, I K; Park, H S; Shim, C S

    2013-06-01

    Nonvariceal upper gastrointestinal (UGI) bleeding recurs after appropriate endoscopic therapy in 10 % - 15 % of cases. The mortality rate can be as high as 25 % when bleeding recurs, but there is no consensus about the best modality for endoscopic re-treatment. The aim of this study was to evaluate clipping and detachable snaring (CDS) for rescue endoscopic control of nonvariceal UGI hemorrhage. We report a case series of seven patients from a Korean tertiary center who underwent endoscopic hemostasis using the combined method of detachable snares with hemoclips. The success rate of endoscopic hemostasis with CDS was 86 %: six of the seven patients who had experienced primary endoscopic treatment failure or recurrent bleeding after endoscopic hemostasis were treated successfully. In conclusion, rescue endoscopic bleeding control by means of CDS is an option for controlling nonvariceal UGI bleeding when no other method of endoscopic treatment for recurrent bleeding and primary hemostatic failure is possible. © Georg Thieme Verlag KG Stuttgart · New York.

  1. endoscope-i: an innovation in mobile endoscopic technology transforming the delivery of patient care in otolaryngology.

    PubMed

    Mistry, N; Coulson, C; George, A

    2017-11-01

    Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.

  2. Percutaneous transgastric irrigation drainage in combination with endoscopic necrosectomy in necrotizing pancreatitis (with videos).

    PubMed

    Raczynski, Susanne; Teich, Niels; Borte, Gudrun; Wittenburg, Henning; Mössner, Joachim; Caca, Karel

    2006-09-01

    Endoscopic drainage of pancreatic acute and chronic pseudocysts and pancreatic necrosectomy have been shown to be beneficial for critically ill patients, with complete endoscopic resolution rates of around 80%. Our purpose was to describe an improved endoscopic technique used to treat pancreatic necrosis. Case report. University hospital. Two patients with large retroperitoneal necroses were treated with percutaneous transgastric retroperitoneal flushing tubes and a percutaneous transgastric jejunal feeding tube by standard percutaneous endoscopic gastrostomy access in addition to endoscopic necrosectomy. Intensive percutaneous transgastric flushing in combination with percutaneous normocaloric enteral nutrition and repeated endoscopic necrosectomy led to excellent outcomes in both patients. Small number of patients. The "double percutaneous endoscopic gastrostomy" approach for simultaneous transgastric drainage and normocaloric enteral nutrition in severe cases of pancreatic necroses is safe and effective. It could be a promising improvement to endoscopic transgastric treatment options in necrotizing pancreatitis.

  3. [Endoscopic Approach to the Quadrilateral Plate (EAQUAL): a New Endoscopic Approach for Plate Osteosynthesis of the Pelvic Ring and Acetabulum - a Cadaver Study].

    PubMed

    Trulson, Alexander; Küper, Markus Alexander; Trulson, Inga Maria; Minarski, Christian; Grünwald, Leonard; Hirt, Bernhard; Stöckle, Ulrich; Stuby, Fabian

    2018-06-14

    Dislocated pelvic fractures which require surgical repair are usually operated on via open surgery. Approach-related morbidity is reported with a frequency of up to 30%. The aim of this anatomical study was to prove the feasibility of endoscopic visualisation of the relevant anatomical structures in pelvic surgery and to perform completely endoscopic plate osteosynthesis of the acetabulum with available standard laparoscopic instruments. In four human cadavers, we established an endoscopic preparation of the complete pelvic ring, from the symphysis to the iliosacral joint, including the quadrilateral plate and the sciatic nerve, and performed endoscopic plate osteosynthesis along the iliopectineal line. The endoscopic preparation of the complete pelvic ring and the quadrilateral plate was demonstrated step-by-step, followed by completely endoscopic plate osteosynthesis along the pelvic brim. Endoscopic, radiographic, and schematic pictures are used to illustrate the technique. The completely endoscopic preparation of the pelvic brim and the quadrilateral plate is feasible with available standard laparoscopic instruments. Moreover, plate osteosynthesis could be performed endoscopically. Further research on reduction techniques is necessary when planning to implement this technique into a clinical scenario. Georg Thieme Verlag KG Stuttgart · New York.

  4. Sphincterotomy in patients with gallstones, elevated LFTs and a normal CBD on ERCP.

    PubMed

    Siddique, Iqbal; Mohan, Krishna; Khajah, Abdulkareem; Hasan, Fuad; Memon, Anjum; Kalaoui, Maher; al-Shamali, Mohammad; Patty, Istvan; al-Nakib, Basil

    2003-01-01

    To determine whether an endoscopic sphincterotomy affects outcome in patients with symptomatic gallstones, elevated liver function tests and a normal common bile duct on endoscopic retrograde cholangiopancreatogram. A total of 163 patients with symptomatic gallstones and elevated liver function tests, and found to have a normal common bile duct on endoscopic retrograde cholangiopancreatogram were included in the study. Endoscopic sphincterotomy was performed in 78 (47.8%) patients, while 85 (52.1%) patients did not have an endoscopic sphincterotomy. The two groups were compared for detection of small unseen common bile duct stones/debris, endoscopic retrograde cholangiopancreatogram related complications, and biliary complications after cholecystectomy. Small common bile duct stones/debris were recovered in 11/43 (25.5%) patients who had instrumentation of the common bile duct performed after endoscopic sphincterotomy. Common bile duct instrumentation was not performed in any of the patients without endoscopic sphincterotomy. No patient had any biliary complication after cholecystectomy, both in the immediate postoperative period and on a follow-up of 37.5 +/- 13.6 months (range 17-66). Endoscopic retrograde cholangiopancreatogram related complications occurred in 8 patients who had an endoscopic sphincterotomy and in 2 without endoscopic sphincterotomy (p < 0.05). Performing an endoscopic sphincterotomy in these patients increases the detection of small unseen common bile duct stones/debris without changing the clinical outcome after cholecystectomy. It also increases the endoscopic retrograde cholangiopancreatogram related complication rate, and therefore may not be necessary.

  5. Gastric full-thickness suturing during EMR and for treatment of gastric-wall defects (with video).

    PubMed

    von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel

    2008-04-01

    The endoscopic full-thickness Plicator device was initially developed to provide an endoscopic treatment option for patients with GERD. Because the endoscopic full-thickness Plicator enables rapid and easy placement of transmural sutures, comparable with surgical sutures, we used the Plicator device for endoscopic treatment or prevention of GI-wall defects. To describe the outcomes and complications of endoscopic full-thickness suturing during EMR and for the treatment of gastric-wall defects. A report of 4 cases treated with the endoscopic full-thickness suturing between June 2006 and April 2007. A large tertiary-referral center. Four subjects received endoscopic full-thickness suturing. The subjects were women, with a mean age of 67 years. Of the 4 subjects, 3 received endoscopic full-thickness suturing during or after an EMR. One subject received endoscopic full-thickness suturing for treatment of a fistula. Primary outcome measurements were clinical procedural success and procedure-related adverse events. The mean time for endoscopic full-thickness suturing was 15 minutes. In all cases, GI-wall patency was restored or ensured, and no procedure-related complications occurred. All subjects responded well to endoscopic full-thickness suturing. The resection of one GI stromal tumor was incomplete. Because of the Plicator's 60F distal-end diameter, endoscopic full-thickness suturing could only be performed with the patient under midazolam and propofol sedation. The durable Plicator suture might compromise the endoscopic follow-up after EMR. The endoscopic full-thickness Plicator permits rapid and easy placement of transmural sutures and seems to be a safe and effective alternative to surgical intervention to restore GI-wall defects or to ensure GI-wall patency during EMR procedures.

  6. Method for radiometric calibration of an endoscope's camera and light source

    NASA Astrophysics Data System (ADS)

    Rai, Lav; Higgins, William E.

    2008-03-01

    An endoscope is a commonly used instrument for performing minimally invasive visual examination of the tissues inside the body. A physician uses the endoscopic video images to identify tissue abnormalities. The images, however, are highly dependent on the optical properties of the endoscope and its orientation and location with respect to the tissue structure. The analysis of endoscopic video images is, therefore, purely subjective. Studies suggest that the fusion of endoscopic video images (providing color and texture information) with virtual endoscopic views (providing structural information) can be useful for assessing various pathologies for several applications: (1) surgical simulation, training, and pedagogy; (2) the creation of a database for pathologies; and (3) the building of patient-specific models. Such fusion requires both geometric and radiometric alignment of endoscopic video images in the texture space. Inconsistent estimates of texture/color of the tissue surface result in seams when multiple endoscopic video images are combined together. This paper (1) identifies the endoscope-dependent variables to be calibrated for objective and consistent estimation of surface texture/color and (2) presents an integrated set of methods to measure them. Results show that the calibration method can be successfully used to estimate objective color/texture values for simple planar scenes, whereas uncalibrated endoscopes performed very poorly for the same tests.

  7. Management of a large mucosal defect after duodenal endoscopic resection

    PubMed Central

    Fujihara, Shintaro; Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Matsunaga, Tae; Ayaki, Maki; Yachida, Tatsuo; Masaki, Tsutomu

    2016-01-01

    Duodenal endoscopic resection is the most difficult type of endoscopic treatment in the gastrointestinal tract (GI) and is technically challenging because of anatomical specificities. In addition to these technical difficulties, this procedure is associated with a significantly higher rate of complication than endoscopic treatment in other parts of the GI tract. Postoperative delayed perforation and bleeding are hazardous complications, and emergency surgical intervention is sometimes required. Therefore, it is urgently necessary to establish a management protocol for preventing serious complications. For instance, the prophylactic closure of large mucosal defects after endoscopic resection may reduce the risk of hazardous complications. However, the size of mucosal defects after endoscopic submucosal dissection (ESD) is relatively large compared with the size after endoscopic mucosal resection, making it impossible to achieve complete closure using only conventional clips. The over-the-scope clip and polyglycolic acid sheets with fibrin gel make it possible to close large mucosal defects after duodenal ESD. In addition to the combination of laparoscopic surgery and endoscopic resection, endoscopic full-thickness resection holds therapeutic potential for difficult duodenal lesions and may overcome the disadvantages of endoscopic resection in the near future. This review aims to summarize the complications and closure techniques of large mucosal defects and to highlight some directions for management after duodenal endoscopic treatment. PMID:27547003

  8. An Innovate Robotic Endoscope Guidance System for Transnasal Sinus and Skull Base Surgery: Proof of Concept.

    PubMed

    Friedrich, D T; Sommer, F; Scheithauer, M O; Greve, J; Hoffmann, T K; Schuler, P J

    2017-12-01

    Objective  Advanced transnasal sinus and skull base surgery remains a challenging discipline for head and neck surgeons. Restricted access and space for instrumentation can impede advanced interventions. Thus, we present the combination of an innovative robotic endoscope guidance system and a specific endoscope with adjustable viewing angle to facilitate transnasal surgery in a human cadaver model. Materials and Methods  The applicability of the robotic endoscope guidance system with custom foot pedal controller was tested for advanced transnasal surgery on a fresh frozen human cadaver head. Visualization was enabled using a commercially available endoscope with adjustable viewing angle (15-90 degrees). Results  Visualization and instrumentation of all paranasal sinuses, including the anterior and middle skull base, were feasible with the presented setup. Controlling the robotic endoscope guidance system was effectively precise, and the adjustable endoscope lens extended the view in the surgical field without the common change of fixed viewing angle endoscopes. Conclusion  The combination of a robotic endoscope guidance system and an advanced endoscope with adjustable viewing angle enables bimanual surgery in transnasal interventions of the paranasal sinuses and the anterior skull base in a human cadaver model. The adjustable lens allows for the abandonment of fixed-angle endoscopes, saving time and resources, without reducing the quality of imaging.

  9. Enhanced differential evolution to combine optical mouse sensor with image structural patches for robust endoscopic navigation.

    PubMed

    Luo, Xiongbiao; Jayarathne, Uditha L; McLeod, A Jonathan; Mori, Kensaku

    2014-01-01

    Endoscopic navigation generally integrates different modalities of sensory information in order to continuously locate an endoscope relative to suspicious tissues in the body during interventions. Current electromagnetic tracking techniques for endoscopic navigation have limited accuracy due to tissue deformation and magnetic field distortion. To avoid these limitations and improve the endoscopic localization accuracy, this paper proposes a new endoscopic navigation framework that uses an optical mouse sensor to measure the endoscope movements along its viewing direction. We then enhance the differential evolution algorithm by modifying its mutation operation. Based on the enhanced differential evolution method, these movement measurements and image structural patches in endoscopic videos are fused to accurately determine the endoscope position. An evaluation on a dynamic phantom demonstrated that our method provides a more accurate navigation framework. Compared to state-of-the-art methods, it improved the navigation accuracy from 2.4 to 1.6 mm and reduced the processing time from 2.8 to 0.9 seconds.

  10. [Current Status of Endoscopic Resection of Early Gastric Cancer in Korea].

    PubMed

    Jung, Hwoon Yong

    2017-09-25

    Endoscopic resection (Endoscopic mucosal resection [EMR] and endoscopic submucosal dissection [ESD]) is already established as a first-line treatment modality for selected early gastric cancer (EGC). In Korea, the number of endoscopic resection of EGC was explosively increased because of a National Cancer Screening Program and development of devices and techniques. There were many reports on the short-term and long-term outcomes after endoscopic resection in patients with EGC. Long-term outcome in terms of recurrence and death is excellent in both absolute and selected expanded criteria. Furthermore, endoscopic resection might be positioned as primary treatment modality replacing surgical gastrectomy. To obtain these results, selection of patients, perfect en bloc procedure, thorough pathological examination of resected specimen, accurate interpretation of whole process of endoscopic resection, and rational strategy for follow-up is necessary.

  11. Feedback Survey of the Effect, Burden, and Cost of the National Endoscopic Quality Assessment Program during the Past 5 Years in Korea.

    PubMed

    Cho, Yu Kyung; Moon, Jeong Seop; Han, Dong Su; Lee, Yong Chan; Kim, Yeol; Park, Bo Young; Chung, Il-Kwun; Kim, Jin-Oh; Im, Jong Pil; Cha, Jae Myung; Kim, Hyun Gun; Lee, Sang Kil; Lee, Hang Lak; Jang, Jae Young; Kim, Eun Sun; Jung, Yunho; Moon, Chang Mo

    2016-11-01

    In Korea, the nationwide gastric cancer screening program recommends biennial screening for individuals aged 40 years or older by way of either an upper gastrointestinal series or endoscopy. The national endoscopic quality assessment (QA) program began recommending endoscopy in medical institutions in 2009. We aimed to assess the effect, burden, and cost of the QA program from the viewpoint of medical institutions. We surveyed the staff of institutional endoscopic units via e-mail. Staff members from 67 institutions replied. Most doctors were endoscopic specialists. They responded as to whether the QA program raised awareness for endoscopic quality (93%) or improved endoscopic practice (40%). The percentages of responders who reported improvements in the diagnosis of gastric cancer, the qualifications of endoscopists, the quality of facilities and equipment, endoscopic procedure, and endoscopic reprocessing were 69%, 60%, 66%, 82%, and 75%, respectively. Regarding reprocessing, many staff members reported that they had bought new automated endoscopic preprocessors (3%), used more disinfectants (34%), washed endoscopes longer (28%), reduced the number of endoscopies performed to adhere to reprocessing guidelines (9%), and created their own quality education programs (59%). Many responders said they felt that QA was associated with some degree of burden (48%), especially financial burden caused by purchasing new equipment. Reasonable quality standards (45%) and incentives (38%) were considered important to the success of the QA program. Endoscopic quality has improved after 5 years of the mandatory endoscopic QA program.

  12. Building an endoscopic ear surgery program.

    PubMed

    Golub, Justin S

    2016-10-01

    This article discusses background, operative details, and outcomes of endoscopic ear surgery. This information will be helpful for those establishing a new program. Endoscopic ear surgery is growing in popularity. The ideal benefit is in totally transcanal access that would otherwise require a larger incision. The endoscope carries a number of advantages over the microscope, as well as some disadvantages. Several key maneuvers can minimize disadvantages. There is a paucity of studies directly comparing outcomes between endoscopic and microscopic approaches for the same procedure. The endoscope is gaining acceptance as a tool for treating otologic diseases. For interested surgeons, this article can help bridge the transition from microscopic to totally transcanal endoscopic ear surgery for appropriate disease.

  13. Endoscopic neurosurgery "around the corner" with a rigid endoscope. Technical note.

    PubMed

    Hopf, N J

    1999-03-01

    Endoscopically "working around the corner" is presently restricted to the use of flexible endoscopes or an endoscope-assisted microneurosurgical (EAM) technique. In order to overcome the limitations of these solutions, endoscopic equipment and techniques were developed for "working around the corner" with rigid endoscopes. A steering insert with a 5 French working channel is capable of steering instruments around the corner by actively bending the guiding track and consecutively the instrument. A special fixation device enables strict axial rotation of the endoscope in the operating field. Endoscopic procedures "around the corner", including aqueductal stenting, pellucidotomy, third ventriculostomy and biopsy were performed in human cadavers. Special features of the used pediatric neuroendoscope system, i.e., reliable fixation, axial rotation, and controlled steering of instruments, increase the safety and reduce the surgical traumatization in selected cases, such as obstructive hydrocephalus due to a mass lesion in the posterior third ventricle, since endoscopic third ventriculostomy and biopsy can be performed through the same burr hole trephination. Limitations of this technique are given by the size of the foramen of Monro and the height of the third ventricle as well as by the bending angle of the instruments (40-50 degrees).

  14. A beam-splitter-type 3-D endoscope for front view and front-diagonal view images.

    PubMed

    Kamiuchi, Hiroki; Masamune, Ken; Kuwana, Kenta; Dohi, Takeyoshi; Kim, Keri; Yamashita, Hiromasa; Chiba, Toshio

    2013-01-01

    In endoscopic surgery, surgeons must manipulate an endoscope inside the body cavity to observe a large field-of-view while estimating the distance between surgical instruments and the affected area by reference to the size or motion of the surgical instruments in 2-D endoscopic images on a monitor. Therefore, there is a risk of the endoscope or surgical instruments physically damaging body tissues. To overcome this problem, we developed a Ø7- mm 3-D endoscope that can switch between providing front and front-diagonal view 3-D images by simply rotating its sleeves. This 3-D endoscope consists of a conventional 3-D endoscope and an outer and inner sleeve with a beam splitter and polarization plates. The beam splitter was used for visualizing both the front and front-diagonal view and was set at 25° to the outer sleeve's distal end in order to eliminate a blind spot common to both views. Polarization plates were used to avoid overlap of the two views. We measured signal-to-noise ratio (SNR), sharpness, chromatic aberration (CA), and viewing angle of this 3-D endoscope and evaluated its feasibility in vivo. Compared to the conventional 3-D endoscope, SNR and sharpness of this 3-D endoscope decreased by 20 and 7 %, respectively. No significant difference was found in CA. The viewing angle for both the front and front-diagonal views was about 50°. In the in vivo experiment, this 3-D endoscope can provide clear 3-D images of both views by simply rotating its inner sleeve. The developed 3-D endoscope can provide the front and front-diagonal view by simply rotating the inner sleeve, therefore the risk of damage to fragile body tissues can be significantly decreased.

  15. Flexible endoscopes: structure and function: the endoscopic retrograde cholangiopancreatography elevator system.

    PubMed

    Holland, Pat; Shoop, Nancy M

    2002-01-01

    Flexible endoscopes are complex medical instruments that are easily damaged. In order to maintain the flexible endoscope in optimum working condition, the user must have a thorough understanding of the structure and function of the instrument. This is the fourth in a series of articles presenting an in-depth look at the care and handling of the flexible endoscope. The first three articles discussed the air-water system, the suction channel system, and the mechanical system. This article will focus specifically on the endoscopic retrograde cholangiopancreatography elevator system.

  16. Transvaginal endoscopic partial gastrectomy in porcine models: the role of an extra endoscope for gastric control.

    PubMed

    Nakajima, Kiyokazu; Takahashi, Tsuyoshi; Souma, Yoshihito; Shinzaki, Shinichiro; Yamada, Takuya; Yoshio, Toshiyuki; Nishida, Toshirou

    2008-12-01

    Transvaginal natural orifice translumenal endoscopic surgery (NOTES) gastrectomy is technically challenging, because wide perigastric dissection under appropriate tissue triangulation is unfeasible with current endoscopic instruments alone. The aim of this study was to investigate the feasibility of transvaginal NOTES gastrectomy with the use of an extra endoscope as a retracting device of the stomach. This acute in vivo feasibility study was performed under the approval of the Institutional Animal Care and Use Committee (IACUC). Four female 40-kg pigs received general anesthesia and underwent transvaginal endoscopic partial gastrectomy. Under laparoscopic guidance, the uterus was fixed anteriorly and transvaginal access was established in a standard fashion. The perigastric ligaments were dissected with needle knife/insulation-tipped electrosurgical knife (IT) via transvaginally placed double-channel endoscope. This step was assisted with the second, CO(2)-insufflating endoscope advanced in the stomach (i.e., so-called endoscopic gastric control). A linear stapling device with a flexible shaft was then passed transvaginally, and the anterior gastric wall was partially resected. The specimen was isolated and retrieved through the vagina. Concluding endoscopy was carried out to confirm the absence of mucosal damage due to endoscopic gastric control. This was further confirmed at necropsy immediately after sacrifice. All animals underwent successful transvaginal NOTES gastrectomy. Endoscopic gastric control greatly facilitated perigastric dissection by providing appropriate tissue countertraction on the ligaments. Use of transabdominal (laparoscopic) graspers was thus minimized. There were no intraoperative complications directly related to use of the primary (transvaginal) endoscope or the additional (gastric) endoscope. Distention of downstream bowel after gastric insufflation was minimal with CO(2). No major injuries were noted on gastric mucosa at postmortem investigations. Transvaginal NOTES partial gastrectomy is feasible in porcine models. Use of an extra endoscope to retract the stomach is effective to minimize transabdominal assistance. Further studies on human subjects are necessary to establish this as a safe and attractive ancillary technique in NOTES.

  17. In-Use Evaluation of Peracetic Acid for High-Level Disinfection of Endoscopes.

    PubMed

    Chenjiao, Wu; Hongyan, Zhang; Qing, Gu; Xiaoqi, Zhong; Liying, Gu; Ying, Fang

    2016-01-01

    Many high-level disinfectants have been used for disinfection of endoscopes such as 2% glutaraldehyde (GA), 0.55% ortho-phthalaldehyde (OPA), and peracetic acid (PAA). Both GA and OPA are widely used in disinfection of endoscopes and have been previously discussed, but there is little research on the practical use of PAA as an endoscope disinfectant. An experimental model of a flexible gastrointestinal endoscope being contaminated with 9 strains of microorganism was designed. After the cleaning and disinfecting procedure was completed, we evaluated the biocidal activity (850 ppm PAA, 2% GA, and 0.55% OPA) on our flexible gastrointestinal endoscope model. We also evaluated sterilization effectiveness of PAA on other bacteria, including some antibiotic-resistant bacteria (methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and Clostridium difficile). The residual bacterial colony count number of the PAA-disinfected endoscope was significantly lower than that of the GA- and OPA-disinfected endoscopes. The biocidal effect and efficiency of the endoscope disinfection by PAA appeared to be better than either the GA- or OPA-disinfected endoscope. PAA has demonstrated a good sterilization effect on other bacterial species; of particular note are common antibiotic-resistant bacteria such as methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and Clostridium difficile. The results of this study demonstrate that PAA is a fast and effective high-level disinfectant for use in the reprocessing of flexible endoscopes.

  18. Predictive factors for outcomes of patients undergoing endoscopic therapy for bile leak after hepatobiliary surgery.

    PubMed

    Yabe, Shuntaro; Kato, Hironari; Mizukawa, Sho; Akimoto, Yutaka; Uchida, Daisuke; Seki, Hiroyuki; Tomoda, Takeshi; Matsumoto, Kazuyuki; Yamamoto, Naoki; Horiguchi, Shigeru; Tsutsumi, Koichiro; Okada, Hiroyuki

    2017-05-01

    Endoscopic procedures are used as first-line treatment for bile leak after hepatobiliary surgery. Advances have been made in endoscopic techniques and devices, but few reports have described the effectiveness of endoscopic procedures and the management principles based on severity of bile leak. We evaluated the effectiveness of an endoscopic procedure for the treatment of bile leak after hepatobiliary surgery. Fifty-eight patients underwent an endoscopic procedure for suspected bile leak after hepatobiliary surgery; the presence of bile leak on endoscopic retrograde cholangiopancreatography (ERCP) was evaluated retrospectively. Two groups were created based on bile leak severity at ERCP. We defined success as follows: technical, successful placement of the plastic stent at the intended bile duct; clinical, improvement in symptoms of bile leak; and eventual, disappearance of bile leak at ERCP. We evaluated several factors that influenced the success of the endoscopic procedure and the differences between bile leak severity. Success rates were as follows: technical, 90%; clinical, 79%; and eventual, 71%. Median interval between first endoscopic procedure and achievement of eventual success was 135 days (IQR, 86-257 days). Bile leak severity was the only independent factor associated with eventual success (P = 0.01). Endoscopic therapy is safe and effective for postoperative bile leak. Bile leak severity is the most important factor influencing successful endoscopic therapy. © 2016 Japan Gastroenterological Endoscopy Society.

  19. Utility of the Anterior Oblique-Viewing Endoscope and the Double-Balloon Enteroscope for Endoscopic Retrograde Cholangiopancreatography in Patients with Billroth II Gastrectomy

    PubMed Central

    Sen-yo, Manabu; Kaino, Seiji; Suenaga, Shigeyuki; Uekitani, Toshiyuki; Yoshida, Kanako; Harano, Megumi; Sakaida, Isao

    2012-01-01

    Background/Purpose. The difficulties of endoscopic retrograde cholangiopancreatography in patients with Billroth II gastrectomy have been reported. We evaluated the usefulness of an anterior oblique-viewing endoscope and a double-balloon enteroscope for endoscopic retrograde cholangiopancreatography in such patients. Methods. From January 2003 to December 2011, 65 patients with Billroth II gastrectomy were enrolled in this study. An anterior oblique-viewing endoscope was used for all patients. From February 2007, a double-balloon enteroscope was used for the failed cases. The success rate of procedures was compared with those in 20 patients with Billroth II gastrectomy using forward-viewing endoscope or side-viewing endoscope from March 1996 to July 2002 as historical controls. Results. In all patients in whom the papilla was reached (60/65), selective cannulation was achieved. The success rate of selective cannulation and accomplishment of planned procedures in the anterior oblique-viewing endoscope group were both significantly higher than that in the control group (100% versus 70.1%, 100 versus 58.8%, resp.). A double-balloon enteroscope was used in 2 patients, and the papilla could be reached and the planned procedures completed. Conclusions. An anterior oblique-viewing endoscope and double-balloon enteroscope appear to be useful in performing endoscopic retrograde cholangiopancreatography in patients with Billroth II gastrectomy. PMID:23056039

  20. Principles of endoscopic ear surgery.

    PubMed

    Tarabichi, Muaaz; Kapadia, Mustafa

    2016-10-01

    The aim of this review is to study the rationale, limitations, techniques, and long-term outcomes of endoscopic ear surgery. The article discusses the advantages of endoscopic ear surgery in treating cholesteatoma and how the hidden sites like facial recess, sinus tympani, and anterior epitympanum are easily accessed using the endoscope. Transcanal endoscopic approach allows minimally invasive removal of cholesteatoma with results that compare well to traditional postauricular tympanomastoidectomy.

  1. Fecal Calprotectin Levels Are Closely Correlated with the Absence of Relevant Mucosal Lesions in Postoperative Crohn's Disease.

    PubMed

    Garcia-Planella, Esther; Mañosa, Míriam; Cabré, Eduard; Marín, Laura; Gordillo, Jordi; Zabana, Yamile; Boix, Jaume; Sáinz, Sergio; Domènech, Eugeni

    2016-12-01

    Fecal calprotectin (FC) is the best noninvasive biomarker of disease activity in inflammatory bowel disease. Its correlation with endoscopic mucosal lesions could save inconvenient, expensive, and repeated endoscopic examinations in particular clinical settings. To assess the correlation between FC and the existence and severity of endoscopic postoperative recurrence (POR), a group of clinically stable outpatients with Crohn's disease for whom an ileocolonoscopy was routinely planned to assess POR were invited to collect a stool sample before starting bowel cleansing to measure FC. POR was graded by means of Rutgeerts endoscopic score. One hundred nineteen ileocolonoscopies were included, 42% with endoscopic POR. FC was significantly lower in the absence of endoscopic POR and in the absence of any endoscopic lesion. The area under the receiver operating characteristic curve was 0.76 (95% confidence interval, 0.68-0.85) for the diagnosis of the absence of lesions and 0.75 (95% confidence interval, 0.66-0.84) for endoscopic POR. Better sensitivity and negative predictive value were observed when combining FC and serum C-reactive protein (CRP), leading to a sensitivity of 82%, a specificity of 53%, and negative and positive predictive values of 81% and 54%, respectively, for the prediction of endoscopic POR with a combination of FC 100 μg/g and CRP 5 mg/L cutoff values. FC correlates closely with endoscopic POR in clinically stable postoperative patients with Crohn's disease and, when used in combination with CRP, might save endoscopic examinations and allow for a high-grade suspicion of endoscopic POR in the long-term monitoring of these patients.

  2. Endoscopic manometry of the sphincter of Oddi in sphincterotomized patients.

    PubMed

    Ugljesić, M; Bulajić, M; Milosavljević, T; Stimec, B

    1995-01-01

    Endoscopic sphincterotomy (ES) of the sphincter of Oddi (SO) has been accepted as an effective method in extraction of common bile duct stones in postcholecystectomy patients. The purpose of this study was to examine the completeness of the performed ES and observe the post sphincterotomy pancreatic duct sphincter (PDS) activity using endoscopic manometry. Activity of the sphincter of Oddi was examined in 15 sphincterotomized patients using endoscopic manometry one to 2.5 years after endoscopic sphincterotomy for choledocholithiasis. In eight patients absence of choledochoduodenal gradient, baseline pressure and the sphincter of Oddi phasic activity up to 2.5 years after endoscopic sphincterotomy indicated a complete sphincterotomy. In seven patients with incomplete endoscopic sphincterotomy, manometry exhibited either a lower choledochoduodenal gradient and baseline pressure without phasic activity of the sphincter of Oddi (three patients), a sphincter of Oddi activity without choledochoduodenal gradient (one patient), or a complete restitution of the sphincter of Oddi activity 1 to 2 years after endoscopic sphincterotomy (three patients). In five patients, with complete endoscopic sphincterotomy, measurements of pancreatic sphincter activity showed lower values of the pancreatic ductal pressure and baseline pressure, while the pancreatic sphincter phasic activity was equal to that found in the control group. Endoscopic manometry is method which enables us to test the completeness of endoscopic sphincterotomy and to follow the restitution of the phasic contractile function of the sphincter. Manometric findings reveal pancreatic sphincter in most patients as a separate sphincteric entity, the function of which is reduced but not eliminated by a complete endoscopic sphincterotomy.

  3. Quality assurance manual of endoscopic screening for gastric cancer in Japanese communities.

    PubMed

    Hamashima, Chisato; Fukao, Akira

    2016-09-02

    The Japanese government introduced endoscopic screening for gastric cancer in 2015 as a public policy based on the Japanese guidelines on gastric cancer screening. To provide appropriate endoscopic screening for gastric cancer in Japanese communities, we developed a quality assurance manual of endoscopic screening and recommend 10 strategies with their brief descriptions as follows: (i) Formulation of a committee responsible for implementing and managing endoscopic screening, and for deciding the suitable implementation methods in consideration of the local context; (ii) Development of an interpretation system that leads to a final judgement to standardize endoscopic examination and improve its accuracy; (iii) Preparation of management and reporting systems for adverse effects by the committee for safety management; (iv) Obtaining informed consent before operation following adequate explanations regarding the benefits and harms of endoscopic screening; (v) Avoidance of frequent screenings to reduce false-positive results and overdiagnosis. As a reference, the target age group is ≥50 years, and the screening interval is 2 years; (vi) Keeping the biopsy rate within 10% as post-biopsy bleeding may occur. Before endoscopic screening, any history of antithrombotic drug usage should be checked; (vii) Nonadministration of sedation in endoscopic screening for safety management; (viii) Adherence to proper endoscopic cleaning and disinfection to reduce infection; (ix) Use of a checklist to achieve optimal program preparation when municipal governments introduce endoscopic screening; (x) Identification of the aims and roles by referring to a checklist if primary care physicians decide to participate in endoscopic screening. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Endoscopic versus surgical drainage treatment of calcific chronic pancreatitis.

    PubMed

    Jiang, Li; Ning, Deng; Cheng, Qi; Chen, Xiao-Ping

    2018-04-21

    Endoscopic therapy and surgery are both conventional treatments to remove pancreatic duct stones that developed during the natural course of chronic pancreatitis. However, few studies comparing the effect and safety between surgery drainage and endoscopic drainage (plus Extracorporeal Shock Wave Lithotripsy, ESWL).The aim of this study was to compare the benefits between endoscopic and surgical drainage of the pancreatic duct for patients with calcified chronic pancreatitis. A total of 86 patients were classified into endoscopic/ESWL (n = 40) or surgical (n = 46) treatment groups. The medical records of these patients were retrospectively analyzed. Pain recurrence and hospital stays were similar between the endoscopic/ESWL treatment and surgery group. However, endoscopic/ESWL treatment yielded significantly lower medical expense and less complications compared with the surgical treatment. In selective patients, endoscopic/ESWL treatment could achieve comparable efficacy to the surgical treatment. With lower medical expense and less complications, endoscopic/ESWL treatment would be much preferred to be the initial treatment of choice for patients with calcified chronic pancreatitis. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  5. Endoscopic management of pancreatic fluid collections-revisited

    PubMed Central

    Nabi, Zaheer; Basha, Jahangeer; Reddy, D Nageshwar

    2017-01-01

    The development of pancreatic fluid collections (PFC) is one of the most common complications of acute severe pancreatitis. Most of the acute pancreatic fluid collections resolve and do not require endoscopic drainage. However, a substantial proportion of acute necrotic collections get walled off and may require drainage. Endoscopic drainage of PFC is now the preferred mode of drainage due to reduced morbidity and mortality as compared to surgical or percutaneous drainage. With the introduction of new metal stents, the efficiency of endoscopic drainage has improved and the task of direct endoscopic necrosectomy has become easier. The requirement of re-intervention is less with new metal stents as compared to plastic stents. However, endoscopic drainage is not free of adverse events. Severe complications including bleeding, perforation, sepsis and embolism have been described with endoscopic approach to PFC. Therefore, the endoscopic management of PFC is a multidisciplinary affair and involves interventional radiologists as well as GI surgeons to deal with unplanned adverse events and failures. In this review we discuss the recent advances and controversies in the endoscopic management of PFC. PMID:28487603

  6. Endoscopic management of colorectal adenomas.

    PubMed

    Meier, Benjamin; Caca, Karel; Fischer, Andreas; Schmidt, Arthur

    2017-01-01

    Colorectal adenomas are well known precursors of invasive adenocarcinoma. Colonoscopy is the gold standard for adenoma detection. Colonoscopy is far more than a diagnostic tool, as it allows effective treatment of colorectal adenomas. Endoscopic resection of colorectal adenomas has been shown to reduce the incidence and mortality of colorectal cancer. Difficult resection techniques are available, such as endoscopic mucosal resection, endoscopic submucosal dissection and endoscopic full-thickness resection. This review aims to provide an overview of the different endoscopic resection techniques and their indications, and summarizes the current recommendations in the recently published guideline of the European Society of Gastrointestinal Endoscopy.

  7. Endoscopic management of colorectal adenomas

    PubMed Central

    Meier, Benjamin; Caca, Karel; Fischer, Andreas; Schmidt, Arthur

    2017-01-01

    Colorectal adenomas are well known precursors of invasive adenocarcinoma. Colonoscopy is the gold standard for adenoma detection. Colonoscopy is far more than a diagnostic tool, as it allows effective treatment of colorectal adenomas. Endoscopic resection of colorectal adenomas has been shown to reduce the incidence and mortality of colorectal cancer. Difficult resection techniques are available, such as endoscopic mucosal resection, endoscopic submucosal dissection and endoscopic full-thickness resection. This review aims to provide an overview of the different endoscopic resection techniques and their indications, and summarizes the current recommendations in the recently published guideline of the European Society of Gastrointestinal Endoscopy. PMID:29118553

  8. A pilot trial of ambulatory monitoring of gastric motility using a modified magnetic capsule endoscope.

    PubMed

    Kim, Hee Man; Choi, Ja Sung; Cho, Jae Hee

    2014-04-30

    The magnetic capsule endoscope has been modified to be fixed inside the stomach and to monitor the gastric motility. This pilot trial was designed to investigate the feasibility of the magnetic capsule endoscope for monitoring gastric motility. The magnetic capsule endoscope was swallowed by the healthy volunteer and maneuvered by the external magnet on his abdomen surface inside the stomach. The magnetic capsule endoscope transmitted image of gastric peristalsis. This simple trial suggested that the real-time ambulatory monitoring of gastric motility should be feasible by using the magnetic capsule endoscope.

  9. Randomized Study Comparing the Effect of Carbon Dioxide Insufflation on Veins Using 2 Types of Endoscopic and Open Vein Harvesting.

    PubMed

    Krishnamoorthy, Bhuvaneswari; Critchley, William R; Nair, Janesh; Malagon, Ignacio; Carey, John; Barnard, James B; Waterworth, Paul D; Venkateswaran, Rajamiyer V; Fildes, James E; Caress, Ann L; Yonan, Nizar

    The aim of the study was to assess whether the use of carbon dioxide insufflation has any impact on integrity of long saphenous vein comparing 2 types of endoscopic vein harvesting and traditional open vein harvesting. A total of 301 patients were prospectively randomized into 3 groups. Group 1 control arm of open vein harvesting (n = 101), group 2 closed tunnel (carbon dioxide) endoscopic vein harvesting (n = 100) and Group 3 open tunnel (carbon dioxide) endoscopic vein harvesting (open tunnel endoscopic vein harvesting) (n = 100). Each group was assessed to determine the systemic level of partial arterial carbon dioxide, end-tidal carbon dioxide, and pH. Three blood samples were obtained at baseline, 10 minutes after start of endoscopic vein harvesting, and 10 minutes after the vein was retrieved. Vein samples were taken immediately after vein harvesting without further surgical handling to measure the histological level of endothelial damage. A modified validated endothelial scoring system was used to compare the extent of endothelial stretching and detachment. The level of end-tidal carbon dioxide was maintained in the open tunnel endoscopic vein harvesting and open vein harvesting groups but increased significantly in the closed tunnel endoscopic vein harvesting group (P = 0.451, P = 0.385, and P < 0.001). Interestingly, partial arterial carbon dioxide also did not differ over time in the open tunnel endoscopic vein harvesting group (P = 0.241), whereas partial arterial carbon dioxide reduced significantly over time in the open vein harvesting group (P = 0.001). A profound increase in partial arterial carbon dioxide was observed in the closed tunnel endoscopic vein harvesting group (P < 0.001). Consistent with these patterns, only the closed tunnel endoscopic vein harvesting group demonstrated a sudden drop in pH over time (P < 0.001), whereas pH remained stable for both open tunnel endoscopic vein harvesting and open vein harvesting groups (P = 0.105 and P = 0.869, respectively). Endothelial integrity was better preserved in the open vein harvesting group compared with open tunnel endoscopic vein harvesting or closed tunnel endoscopic vein harvesting groups (P = 0.012) and was not affected by changes in carbon dioxide or low pH. Significantly greater stretching of the endothelium was observed in the open tunnel endoscopic open tunnel endoscopic vein harvesting group compared with the other groups (P = 0.003). This study demonstrated that the different vein harvesting techniques impact on endothelial integrity; however, this does not seem to be related to the increase in systemic absorption of carbon dioxide or to the pressurized endoscopic tunnel. The open tunnel endoscopic harvesting technique vein had more endothelial stretching compared with the closed tunnel endoscopic technique; this may be due to manual dissection of the vein. Further research is required to evaluate the long-term clinical outcome of these vein grafts.

  10. Effect of endoscopic transpapillary biliary drainage with/without endoscopic sphincterotomy on post-endoscopic retrograde cholangiopancreatography pancreatitis in patients with biliary stricture (E-BEST): a protocol for a multicentre randomised controlled trial

    PubMed Central

    Kato, Shin; Kuwatani, Masaki; Sugiura, Ryo; Sano, Itsuki; Kawakubo, Kazumichi; Ono, Kota; Sakamoto, Naoya

    2017-01-01

    Introduction The effect of endoscopic sphincterotomy prior to endoscopic biliary stenting to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis remains to be fully elucidated. The aim of this study is to prospectively evaluate the non-inferiority of non-endoscopic sphincterotomy prior to stenting for naïve major duodenal papilla compared with endoscopic sphincterotomy prior to stenting in patients with biliary stricture. Methods and analysis We designed a multicentre randomised controlled trial, for which we will recruit 370 patients with biliary stricture requiring endoscopic biliary stenting from 26 high-volume institutions in Japan. Patients will be randomly allocated to the endoscopic sphincterotomy group or the non-endoscopic sphincterotomy group. The main outcome measure is the incidence of pancreatitis within 2 days of initial transpapillary biliary drainage. Data will be analysed on completion of the study. We will calculate the 95% confidence intervals (CIs) of the incidence of pancreatitis in each group and analyse weather the difference in both groups with 95% CIs is within the non-inferiority margin (6%) using the Wald method. Ethics and dissemination This study has been approved by the institutional review board of Hokkaido University Hospital (IRB: 016–0181). Results will be submitted for presentation at an international medical conference and published in a peer-reviewed journal. Trial registration number The University Hospital Medical Information Network ID: UMIN000025727 Pre-results. PMID:28801436

  11. Open Versus Endoscopic Cubital Tunnel In Situ Decompression: A Systematic Review of Outcomes and Complications.

    PubMed

    Toirac, Alexander; Giugale, Juan M; Fowler, John R

    2017-05-01

    Endoscopic cubital tunnel release has been proposed as an alternative to open in situ release. However, it is difficult to analyze outcomes after endoscopic release, as only a few small case series exist. The electronic databases of PubMed (1960-June 2014) were systematically screened for studies related to endoscopic cubital tunnel release or open in situ cubital tunnel release. Baseline characteristics, clinical scores, and complication rates were abstracted. The binary outcome was defined as rate of excellent/good response versus fair/poor. Complications were recorded into 3 categories: wound problems, persistent ulnar nerve symptoms, and other. We included 8 articles that reported the clinical outcomes after surgical intervention including a total of 494 patients (344 endoscopic, 150 open in situ). The pooled rate of excellent/good was 92.0% (88.8%-95.2%) for endoscopic and 82.7% (76.15%-89.2%) for open. We identified 18 articles that detailed complications including a total of 1108 patients (691 endoscopic, 417 open). The 4 articles that listed complication rates for both endoscopic and open techniques were analyzed and showed a pooled odds ratio of 0.280 (95% confidence interval, 0.125-0.625), indicating that endoscopic patients have reduced odds of complications. The results of this systematic review suggest that there is a difference in clinical outcomes between the open in situ and endoscopic cubital tunnel release, with the endoscopic technique being superior in regard to both complication rates along with patient satisfaction.

  12. Comparison of Complications Rates in Endoscopic Surgery Performed by a Clinical Assistant vs. An Experienced Endoscopic Surgeon

    PubMed Central

    Singhi, Aditi

    2009-01-01

    Study Objectives: (a) To find out the actual incidence of complications during endoscopic surgeries. (b) Comparison of complication rate between an experienced laparoscopic surgeon (> 10 years of experience in endoscopic surgery) and a clinical assistant (> 3 years of experience in endoscopic surgery). (c) How to manage complications in endoscopic surgery. (d) Concrete suggestions to reduce the complication rate. Design: Retrospective study (Canadian Task Force classification ii-2). Setting: Tertiary gynecologic endoscopic unit. Patients: A total of 3204 cases of gynecologic endoscopic surgery out of which 2001 were laparoscopic and 1203 were hysteroscopic surgeries. Interventions: Laparoscopic and hysteroscopic gynecologic surgeries in indicated cases. Measurements and Main Results: The study was carried out between April 2003 and October 2007 at a referral center for endoscopic surgery. A total of 3204 cases of gynecologic endoscopic surgery were studied. There were five significant complications in laparoscopic surgeries and four significant complications in hysteroscopic surgeries seen in four years and six months. All the complications could be managed with no mortality. Conversion to laparotomy was needed in eight cases of laparoscopic surgeries and none in hysteroscopic surgeries. Conclusion: The risk of complication reduces with the experience in endoscopic surgery. However, the proper grooming of a novice in experienced hands, for a sufficient period of time, can minimize the complication rate in the initial learning phase. The complication may be utilized as a stepping-stone to overcome any given situation without panic, but with adequate safety. PMID:22442510

  13. Current status of submucosal tunneling endoscopic resection for gastrointestinal submucosal tumors originating from the muscularis propria layer.

    PubMed

    Tan, Yuyong; Huo, Jirong; Liu, Deliang

    2017-11-01

    Gastrointestinal submucosal tumors (SMTs) have been increasingly identified via the use of endoscopic ultrasonography, and removal is often recommended for SMTs that are >2 cm in diameter or symptomatic. Submucosal tunneling endoscopic resection (STER), also known as submucosal endoscopic tumor resection, endoscopic submucosal tunnel dissection or tunneling endoscopic muscularis dissection, is a novel endoscopic technique for treating gastrointestinal SMTs originating from the muscularis propria layer, and has been demonstrated to be effective in the removal of SMTs with a decreased rate of recurrence by clinical studies. STER may be performed for patients with esophageal or cardia SMTs, and its application has expanded beyond these types of SMTs due to modifications to the technique. The present study reviewed the applications, procedure, efficacy and complications associated with STER.

  14. Endoscopic treatments for portal hypertension.

    PubMed

    Lo, Gin-Ho

    2018-02-01

    Acute esophageal variceal hemorrhage is a dreaded complication of portal hypertension. Its management has evolved rapidly in recent years. Endoscopic therapy is often employed to arrest bleeding varices as well as to prevent early rebleeding. The combination of vasoconstrictor and endoscopic therapy is superior to vasoconstrictor or endoscopic therapy alone for control of acute esophageal variceal hemorrhage. After control of acute variceal bleeding, combination of banding ligation and beta-blockers is generally recommended to prevent variceal rebleeding. To prevent the catastrophic event of acute variceal bleeding, endoscopic banding ligation is an important tool in the prophylaxis of first bleeding. Endoscopic obturation with cyanoacrylate is usually utilized to arrest acute gastric variceal hemorrhage as well as to prevent rebleeding. It can be concluded that endoscopic therapies play a pivotal role in management of portal hypertensive bleeding.

  15. Supraretinacular endoscopic carpal tunnel release: surgical technique with prospective case series.

    PubMed

    Ecker, J; Perera, N; Ebert, J

    2015-02-01

    Current techniques for endoscopic carpal tunnel release use an infraretinacular approach, inserting the endoscope deep to the flexor retinaculum. We present a supraretinacular endoscopic carpal tunnel release technique in which a dissecting endoscope is inserted superficial to the flexor retinaculum, which improves vision and the ability to dissect and manipulate the median nerve and tendons during surgery. The motor branch of the median nerve and connections between the median and ulnar nerve can be identified and dissected. Because the endoscope is inserted superficial to the flexor retinaculum, the median nerve is not compressed before division of the retinaculum and, as a result, we have observed no cases of the transient median nerve deficits that have been reported using infraretinacular endoscopic techniques. © The Author(s) 2014.

  16. Long-term results after endoscopic drainage and necrosectomy of symptomatic pancreatic fluid collections.

    PubMed

    Seewald, Stefan; Ang, Tiing Leong; Richter, Hugo; Teng, Karl Yu Kim; Zhong, Yan; Groth, Stefan; Omar, Salem; Soehendra, Nib

    2012-01-01

    To determine the immediate and long-term results of endoscopic drainage and necrosectomy for symptomatic pancreatic fluid collections. The data of 80 patients with symptomatic pancreatic fluid collections (mean diameter: 11.7 cm, range 3-20; pseudocysts: 24/80, abscess: 20/80, infected walled-off necrosis: 36/80) referred for endoscopic management from October 1997 to March 2008 were analyzed retrospectively. Endoscopic drainage techniques included endoscopic ultrasound (EUS)-guided aspiration (2/80), EUS-guided transenteric drainage (70/80) and non-EUS-guided drainage across a spontaneous transenteric fistula (8/80). Endoscopic necrosectomy was carried out in 49/80 (abscesses: 14/20; infected necrosis: 35/36). Procedural complications were bleeding (12/80), perforation (7/80), portal air embolism (1/80) and Ogilvie Syndrome (1/80). Initial technical success was achieved in 78/80 (97.5%) and clinical resolution of the collections was achieved endoscopically in 67/80 (83.8%), with surgery required in 13/80 (perforation: four; endoscopically inaccessible areas: two; inadequate drainage: seven). Within 6 months five patients required surgery due to recurrent fluid collections; over a mean follow up of 31 months, surgery was required in four more patients due to recurrent collections as a consequence of underlying pancreatic duct abnormalities that could not be treated endoscopically. The long-term success of endoscopic treatment was 58/80 (72.5%). Endoscopic drainage of symptomatic pancreatic fluid collections is safe and effective, with excellent immediate and long-term results. Endoscopic necrosectomy has a risk of serious complications. The underlying pancreatic duct abnormalities must be addressed to prevent recurrence of fluid collections. © 2011 The Authors. Digestive Endoscopy © 2011 Japan Gastroenterological Endoscopy Society.

  17. Comparison of endoscopic and percutaneous drainage of symptomatic necrotic collections in acute necrotizing pancreatitis.

    PubMed

    Woo, Shanan; Walklin, Ryan; Ackermann, Travis; Lo, Sheng Wei; Shilton, Hamish; Pilgrim, Charles; Evans, Peter; Burnes, James; Croagh, Daniel

    2018-05-10

    Primary endoscopic and percutaneous drainage for pancreatic necrotic collections is increasingly used. We aim to compare the relative effectiveness of both modalities in reducing the duration and severity of illness by measuring their effects on systemic inflammatory response syndrome (SIRS). We retrospectively reviewed all cases of endoscopic and percutaneous drainage for pancreatic necrotic collections performed in 2011-2016 at two hospitals. We assessed the post-procedure length of hospital stay, reduction in C-reactive protein levels, resolution of SIRS, the complication rates, and the number of procedures required for resolution. Thirty-two patients were identified and 57 cases (36 endoscopic, 21 percutaneous) were included. There was no significant difference in C-reactive protein reduction between endoscopic and percutaneous drainage (69.5% vs 68.8%, P = 0.224). Resolution of SIRS was defined as the post-procedure normalization of white cell count (endoscopic vs percutaneous: 70.4% vs 64.3%, P = 0.477), temperature (endoscopic vs percutaneous: 93.3% vs 60.0%, P = 0.064), heart rate (endoscopic vs percutaneous: 56.0% vs 11.1%, P = 0.0234), and respiratory rate (endoscopic vs percutaneous: 83.3% vs 0.0%, P = 0.00339). Post-procedure length of hospital stay was 27 days with endoscopic drainage and 46 days with percutaneous drainage (P = 0.0183). Endoscopic drainage was associated with a shorter post-procedure length of hospital stay and a greater rate of normalization of SIRS parameters than percutaneous drainage, although only the effects on heart rate and respiratory rate reached statistical significance. Further studies are needed to establish which primary drainage modality is superior for pancreatic necrotic collections. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  18. Outcomes of Endoscopic Realignment of Pelvic Fracture Associated Urethral Injuries at a Level 1 Trauma Center

    PubMed Central

    Leddy, Laura S.; Vanni, Alex J.; Wessells, Hunter; Voelzke, Bryan B.

    2012-01-01

    Purpose We examined the success of early endoscopic realignment of pelvic fracture associated urethral injury after blunt pelvic trauma. Materials and Methods A retrospective review was performed of patients with pelvic fracture associated urethral injury who underwent early endoscopic realignment using a retrograde or retrograde/antegrade approach from 2004 to 2010 at a Level 1 trauma center. Followup consisted of uroflowmetry, post-void residual and cystoscopic evaluation. Failure of early endoscopic realignment was defined as patients requiring urethral dilation, direct vision internal urethrotomy, posterior urethroplasty or self-catheterization after initial urethral catheter removal. Results A total of 19 consecutive patients (mean age 38 years) with blunt pelvic fracture associated urethral injury underwent early endoscopic realignment. Twelve cases of complete urethral disruption, 4 of incomplete disruption and 3 of indeterminate status were noted. Mean time to realignment was 2 days and mean duration of urethral catheterization after realignment was 53 days. One patient was lost to followup after early endoscopic realignment. Using an intent to treat analysis early endoscopic realignment failed in 15 of 19 patients (78.9%). Mean time to early endoscopic realignment failure after catheter removal was 79 days. The cases of early endoscopic realignment failure were managed with posterior urethroplasty (8), direct vision internal urethrotomy (3) and direct vision internal urethrotomy followed by posterior urethroplasty (3). Mean followup for the 4 patients considered to have undergone successful early endoscopic realignment was 2.1 years. Conclusions Early endoscopic realignment after blunt pelvic fracture associated urethral injury results in high rates of symptomatic urethral stricture requiring further operative treatment. Close followup after initial catheter removal is warranted, as the mean time to failure after early endoscopic realignment was 79 days in our cohort. PMID:22591965

  19. Correlation between endoscopic forceps biopsies and endoscopic mucosal resection with endoscopic ultrasound in patients with Barrett's esophagus with high-grade dysplasia and early cancer.

    PubMed

    Thota, Prashanthi N; Sada, Alaa; Sanaka, Madhusudhan R; Jang, Sunguk; Lopez, Rocio; Goldblum, John R; Liu, Xiuli; Dumot, John A; Vargo, John; Zuccarro, Gregory

    2017-03-01

    Patients with Barrett's esophagus (BE) and high-grade dysplasia (HGD) or intramucosal cancer (IMC) on endoscopic forceps biopsies are referred to endoscopic therapy even though forceps biopsies do not reflect the disease extent accurately. Endoscopic mucosal resection (EMR) and endoscopic ultrasound (EUS) are frequently used for staging prior to endoscopic therapy. Our aims were to evaluate: (1) if endoscopic forceps biopsies correlated with EMR histology in these patients; (2) the utility of EUS compared to EMR; and (3) if accuracy of EUS varied based on grade of differentiation of tumor. This is a retrospective review of patients referred to endoscopic therapy of BE with HGD or early esophageal adenocarcinoma (EAC) who underwent EMR from 2006 to 2011. Age, race, sex, length of Barrett's segment, hiatal hernia size, number of endoscopies and biopsy results and EUS findings were abstracted. A total of 151 patients underwent EMR. In 50 % (75/151) of patients, EMR histology was consistent with endoscopic forceps biopsy findings. EMR resulted in change in diagnosis with upstaging in 21 % (32/151) and downstaging in 29 % (44/151). In patients with HGD on EMR, EUS staging was T0 in 74.1 % (23/31) but upstaged in 25.8 % (8/31). In patients with IMC on EMR, EUS findings were T1a in 23.6 % (9/38), upstaged in 18.4 % (7/38) and downstaged in 57.8 % (22/38). EUS accurately identified EMR histology in all submucosal cancers. Grade of differentiation was reported in 24 cancers on EMR histology. There was no correlation between grade and EUS staging. EUS is of limited utility in accurate staging of BE patients with HGD or early EAC. Endoscopic forceps biopsy correlated with EMR findings in only 50 % of patients. Irrespective of the endoscopic forceps biopsy results, all BE patients with visible lesions should be referred to EMR.

  20. Endoscopic approaches to treatment of achalasia

    PubMed Central

    Friedel, David; Modayil, Rani; Iqbal, Shahzad; Grendell, James H.

    2013-01-01

    Endoscopic therapy for achalasia is directed at disrupting or weakening the lower esophageal sphincter (LES). The two most commonly utilized endoscopic interventions are large balloon pneumatic dilation (PD) and botulinum toxin injection (BTI). These interventions have been extensively scrutinized and compared with each other as well as with surgical disruption (myotomy) of the LES. PD is generally more effective in improving dysphagia in achalasia than BTI, with the latter reserved for infirm older people, and PD may approach treatment results attained with myotomy. However, PD may need to be repeated. Small balloon dilation and endoscopic stent placement for achalasia have only been used in select centers. Per oral endoscopic myotomy is a newer endoscopic modality that will likely change the treatment paradigm for achalasia. It arose from the field of natural orifice transluminal endoscopic surgery and represents a scarless endoscopic approach to Heller myotomy. This is a technique that requires extensive training and preparation and thus there should be rigorous accreditation and monitoring of outcomes to ensure safety and efficacy. PMID:23503707

  1. Five-Year Clinical Outcome of Endoscopic Versus Open Radial Artery Harvesting: A Propensity Score Analysis.

    PubMed

    Bisleri, Gianluigi; Giroletti, Laura; Hrapkowicz, Tomasz; Bertuletti, Martina; Zembala, Marian; Arieti, Mario; Muneretto, Claudio

    2016-10-01

    Despite the popularity of less invasive approaches for conduits procurement in coronary artery bypass graft surgery, concerns have been raised about the potential detrimental effects of the endoscopic technique when compared with the conventional "open" technique. Among 470 patients undergoing coronary surgery with the use of a radial artery conduit, a propensity score analysis was performed among those patients assigned either to an open technique (n = 82) or to an endoscopic approach (n = 82). Endoscopic harvesting was performed with a nonsealed system. The primary endpoint was cardiac-related mortality, and secondary endpoint was survival free from major cardiac and cerebrovascular adverse events. Moreover, hand and forearm sensory discomfort and forearm wound healing were also assessed. No conversion to the open technique occurred in patients undergoing endoscopic harvesting. No patients in either group showed hand ischemia; wound infection occurred only in the open group (open 7.3% versus endoscopic 0%, p = 0.007). Wound healing (Hollander scale) was considerably better in the endoscopic group (open 3.3, endoscopic 4.7; p < 0.001) as well as paresthesia at the latest follow-up (open 19.5% versus endoscopic 3.6%, p < 0.001). Pain (visual analog scale score) was significantly reduced with the endoscopic technique (open 3.2, endoscopic 1.2; p = 0.003). At 5 years of follow-up, freedom from cardiac-related mortality (open 96.3% ± 2.1% versus endoscopic 98.1% ± 1.8%; p = 0.448) as well as survival free from major cardiac and cerebrovascular adverse events (open 93.9% ± 2.6% versus endoscopic 93% ± 3.4%; p = 0.996) were similar among the groups. Endoscopic radial artery harvesting allows for incremental benefits in the short term in terms of improved cosmesis and reduced wound and neurologic complications, without yielding detrimental effects in terms of graft-related events at 5 years of follow-up. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. The application of percutaneous endoscopic colostomy to the management of obstructed defecation.

    PubMed

    Heriot, A G; Tilney, H S; Simson, J N L

    2002-05-01

    We describe the case of a 52-year woman with a 17-year history of obstructed defecation in whom all other standard treatments had failed and the patient had refused a colostomy. Her symptoms were controlled by percutaneous endoscopic colostomy with antegrade colonic irrigation. A percutaneous endoscopic colostomy tube was placed in the sigmoid colon endoscopically using a colonoscope and the patient irrigated two liters of water through the percutaneous endoscopic colostomy twice each day and was able to successfully evacuate her rectum without excess straining or discomfort. Percutaneous endoscopic colostomy is an alternative option to colostomy in the management of obstructed defecation.

  3. Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Herz, P. R.; Chen, Y.; Aguirre, A. D.; Schneider, K.; Hsiung, P.; Fujimoto, J. G.; Madden, K.; Schmitt, J.; Goodnow, J.; Petersen, C.

    2004-10-01

    A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-µm axial resolution by use of a femtosecond Crforsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

  4. Extended Endoscopic and Open Sinus Surgery for Refractory Chronic Rhinosinusitis.

    PubMed

    Eloy, Jean Anderson; Marchiano, Emily; Vázquez, Alejandro

    2017-02-01

    This review discusses extended endoscopic and open sinus surgery for refractory chronic rhinosinusitis. Extended maxillary sinus surgery including endoscopic maxillary mega-antrostomy, endoscopic modified medial maxillectomy, and inferior meatal antrostomy are described. Total/complete ethmoidectomy with mucosal stripping (nasalization) is discussed. Extended endoscopic sphenoid sinus procedures as well as their indications and potential risks are reviewed. Extended endoscopic frontal sinus procedures, such the modified Lothrop procedure, are described. Extended open sinus surgical procedures, such as the Caldwell-Luc approach, frontal sinus trephine procedure, external frontoethmoidectomy, frontal sinus osteoplastic flap with or without obliteration, and cranialization, are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Improving the Endoscopic Detection Rate in Patients with Early Gastric Cancer

    PubMed Central

    2015-01-01

    Endoscopists should ideally possess both sufficient knowledge of the endoscopic gastrointestinal disease findings and an appropriate attitude. Before performing endoscopy, the endoscopist must identify several risk factors of gastric cancer, including the patient's age, comorbidities, and drug history, a family history of gastric cancer, previous endoscopic findings of atrophic gastritis or intestinal metaplasia, and a history of previous endoscopic treatments. During endoscopic examination, the macroscopic appearance is very important for the diagnosis of early gastric cancer; therefore, the endoscopist should have a consistent and organized endoscope processing technique and the ability to comprehensively investigate the entire stomach, even blind spots. PMID:26240801

  6. Gastrointestinal endoscopy in pregnancy

    PubMed Central

    Savas, Nurten

    2014-01-01

    Gastrointestinal endoscopy has a major diagnostic and therapeutic role in most gastrointestinal disorders; however, limited information is available about clinical efficacy and safety in pregnant patients. The major risks of endoscopy during pregnancy include potential harm to the fetus because of hypoxia, premature labor, trauma and teratogenesis. In some cases, endoscopic procedures may be postponed until after delivery. When emergency or urgent indications are present, endoscopic procedures may be considered with some precautions. United States Food and Drug Administration category B drugs may be used in low doses. Endoscopic procedures during pregnancy may include upper gastrointestinal endoscopy, percutaneous endoscopic gastrostomy, sigmoidoscopy, colonoscopy, enteroscopy of the small bowel or video capsule endoscopy, endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography. All gastrointestinal endoscopic procedures in pregnant patients should be performed in hospitals by expert endoscopists and an obstetrician should be informed about all endoscopic procedures. The endoscopy and flexible sigmoidoscopy may be safe for the fetus and pregnant patient, and may be performed during pregnancy when strong indications are present. Colonoscopy for pregnant patients may be considered for strong indications during the second trimester. Although therapeutic endoscopic retrograde cholangiopancreatography may be considered during pregnancy, this procedure should be performed only for strong indications and attempts should be made to minimize radiation exposure. PMID:25386072

  7. Quantitative endoscopy: initial accuracy measurements.

    PubMed

    Truitt, T O; Adelman, R A; Kelly, D H; Willging, J P

    2000-02-01

    The geometric optics of an endoscope can be used to determine the absolute size of an object in an endoscopic field without knowing the actual distance from the object. This study explores the accuracy of a technique that estimates absolute object size from endoscopic images. Quantitative endoscopy involves calibrating a rigid endoscope to produce size estimates from 2 images taken with a known traveled distance between the images. The heights of 12 samples, ranging in size from 0.78 to 11.80 mm, were estimated with this calibrated endoscope. Backup distances of 5 mm and 10 mm were used for comparison. The mean percent error for all estimated measurements when compared with the actual object sizes was 1.12%. The mean errors for 5-mm and 10-mm backup distances were 0.76% and 1.65%, respectively. The mean errors for objects <2 mm and > or =2 mm were 0.94% and 1.18%, respectively. Quantitative endoscopy estimates endoscopic image size to within 5% of the actual object size. This method remains promising for quantitatively evaluating object size from endoscopic images. It does not require knowledge of the absolute distance of the endoscope from the object, rather, only the distance traveled by the endoscope between images.

  8. Management of Inflammatory Fluid Collections and Walled-Off Pancreatic Necrosis.

    PubMed

    Shah, Apeksha; Denicola, Richard; Edirisuriya, Cynthia; Siddiqui, Ali A

    2017-12-01

    Pancreatic fluid collections are a frequent complication of acute pancreatitis. The revised Atlanta criterion classifies chronic fluid collections into pseudocysts and walled-off pancreatic necrosis (WON). Symptomatic PFCs require drainage options that include surgical, percutaneous, or endoscopic approaches. With the advent of newer and more advanced endoscopic tools and expertise, minimally invasive endoscopic drainage has now become the preferred approach. An endoscopic ultrasonography (EUS)-guided approach for pancreatic fluid collection drainage is now the preferred endoscopic approach. Both plastic stents and metal stents are efficacious and safe; however, metal stents may offer an advantage, especially in infected pseudocysts and in WON. Direct endoscopic necrosectomy is often required in WON. Lumen apposing metal stents allow for direct endoscopic necrosectomy and debridement through the stent lumen and are now preferred in these patients. Endoscopic retrograde cholangiopancreatography with pancreatic duct exploration should be performed concurrent to PFC drainage in patients with suspected PD disruption. PD disruption is associated with an increased severity of pancreatitis, an increased risk of recurrent attacks of pancreatitis and long-term complications, and a decreased rate of PFC resolution after drainage. Ideally, pancreatic ductal disruption should be bridged with endoscopic stenting.

  9. The Steris Reliance EPS endoscope processing system: a new automated endoscope reprocessing technology.

    PubMed

    2007-01-01

    In this Evaluation, we examine whether the Steris Reliance EPS--a flexible endoscope reprocessing system that was recently introduced to the U.S. market--offers meaningful advantages over "traditional" automated endoscope reprocessors (AERs). Most AERs on the market function similarly to one another. The Reliance EPS, however, includes some unique features that distinguish it from other AERs. For example, it incorporates a "boot" technology for loading the endoscopes into the unit without requiring a lot of endoscope-specific connectors, and it dispenses the germicide used to disinfect the endoscopes from a single-use container. This Evaluation looks at whether the unique features of this model make it a better choice than traditional AERs for reprocessing flexible endoscopes. Our study focuses on whether the Reliance EPS is any more likely to be used correctly-thereby reducing the likelihood that an endoscope will be reprocessed inadequately-and whether the unit possesses any design flaws that could lead to reprocessing failures. We detail the unit's advantages and disadvantages compared with other AERs, and we describe what current users have to say. Our conclusions will help facilities determine whether to select the Reliance EPS.

  10. Future Development of Endoscopic Accessories for Endoscopic Submucosal Dissection

    PubMed Central

    Jang, Jae-Young

    2017-01-01

    Endoscopic submucosal dissection (ESD) has recently been accepted as a standard treatment for patients with early gastric cancer (EGC), without lymph node metastases. Given the rise in the number of ESDs being performed, new endoscopic accessories are being developed and existing accessories modified to facilitate the execution of ESD and reduce complication rates. This paper examines the history underlying the development of these new endoscopic accessories and indicates future directions for the development of these accessories. PMID:28609819

  11. Hot biopsy forceps vs. endoscopic ultrasonography in determining the depth of gastric epithelial neoplasia: a simple novel method to decide whether or not to perform endoscopic submucosal dissection.

    PubMed

    Huikai, Li; Enqiang, Linghu

    2013-01-01

    It is of vital importance to determine the depth of lesions to be treated by endoscopic submucosal dissection. This study aimed to compare the accuracy of using hot biopsy forceps method with endoscopic ultrasonography for determination of the depth of gastric epithelial neoplasia. Hot biopsy forceps method and/or endoscopic ultrasonography were used to determine the depth of lesions in 27 patients. With hot biopsy forceps method, we assumed a lesion completely lifted up by a hot biopsy forceps to be confined to the mucosal layer, and one partly lifted up to be located beyond the mucosal layer. The accuracy of hot biopsy forceps method and endoscopic ultrasonography in determining the depth of lesions were compared. Of the 27 patients, 25 underwent endoscopic submucosal dissection and 2 underwent surgery. The total accuracy of hot biopsy forceps method in determining the depth of lesions was 92.6% and that of endoscopic ultrasonography was 81.8%. Overestimation of hot biopsy forceps method and endoscopic ultrasonography were 3.7% vs. 13.6%, respectively. The sensitivity and the specificity of hot biopsy forceps method were 95.5% and 80.0% and those of EUS were 83.3% and 75.0%. Hot biopsy forceps method has a trend towards higher accuracy and lower overestimation than endoscopic ultrasonography.

  12. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    PubMed

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Effect of endoscopic transpapillary biliary drainage with/without endoscopic sphincterotomy on post-endoscopic retrograde cholangiopancreatography pancreatitis in patients with biliary stricture (E-BEST): a protocol for a multicentre randomised controlled trial.

    PubMed

    Kato, Shin; Kuwatani, Masaki; Sugiura, Ryo; Sano, Itsuki; Kawakubo, Kazumichi; Ono, Kota; Sakamoto, Naoya

    2017-08-11

    The effect of endoscopic sphincterotomy prior to endoscopic biliary stenting to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis remains to be fully elucidated. The aim of this study is to prospectively evaluate the non-inferiority of non-endoscopic sphincterotomy prior to stenting for naïve major duodenal papilla compared with endoscopic sphincterotomy prior to stenting in patients with biliary stricture. We designed a multicentre randomised controlled trial, for which we will recruit 370 patients with biliary stricture requiring endoscopic biliary stenting from 26 high-volume institutions in Japan. Patients will be randomly allocated to the endoscopic sphincterotomy group or the non-endoscopic sphincterotomy group. The main outcome measure is the incidence of pancreatitis within 2 days of initial transpapillary biliary drainage. Data will be analysed on completion of the study. We will calculate the 95% confidence intervals (CIs) of the incidence of pancreatitis in each group and analyse weather the difference in both groups with 95% CIs is within the non-inferiority margin (6%) using the Wald method. This study has been approved by the institutional review board of Hokkaido University Hospital (IRB: 016-0181). Results will be submitted for presentation at an international medical conference and published in a peer-reviewed journal. The University Hospital Medical Information Network ID: UMIN000025727 Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Monitoring of endoscope reprocessing with an adenosine triphosphate (ATP) bioluminescence method.

    PubMed

    Parohl, Nina; Stiefenhöfer, Doris; Heiligtag, Sabine; Reuter, Henning; Dopadlik, Dana; Mosel, Frank; Gerken, Guido; Dechêne, Alexander; Heintschel von Heinegg, Evelyn; Jochum, Christoph; Buer, Jan; Popp, Walter

    2017-01-01

    Background: The arising challenges over endoscope reprocessing quality proposes to look for possibilities to measure and control the process of endoscope reprocessing. Aim: The goal of this study was to evaluate the feasibility of monitoring endoscope reprocessing with an adenosine triphosphate (ATP) based bioluminescence system. Methods: 60 samples of eight gastroscopes have been assessed from routine clinical use in a major university hospital in Germany. Endoscopes have been assessed with an ATP system and microbial cultures at different timepoints during the reprocessing. Findings: After the bedside flush the mean ATP level in relative light units (RLU) was 19,437 RLU, after the manual cleaning 667 RLU and after the automated endoscope reprocessor (AER) 227 RLU. After the manual cleaning the mean total viable count (TVC) per endoscope was 15.3 CFU/10 ml, and after the AER 5.7 CFU/10 ml. Our results show that there are reprocessing cycles which are not able to clean a patient used endoscope. Conclusion: Our data suggest that monitoring of flexible endoscope with ATP can identify a number of different influence factors, like the endoscope condition and the endoscopic procedure, or especially the quality of the bedside flush and manual cleaning before the AER. More process control is one option to identify and improve influence factors to finally increase the overall reprocessing quality, best of all by different methods. ATP measurement seems to be a valid technique that allows an immediate repeat of the manual cleaning if the ATP results after manual cleaning exceed the established cutoff of 200 RLU.

  15. 21 CFR 882.1480 - Neurological endoscope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurological endoscope. 882.1480 Section 882.1480...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1480 Neurological endoscope. (a) Identification. A neurological endoscope is an instrument with a light source used to view the inside of the...

  16. 21 CFR 882.1480 - Neurological endoscope.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Neurological endoscope. 882.1480 Section 882.1480...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1480 Neurological endoscope. (a) Identification. A neurological endoscope is an instrument with a light source used to view the inside of the...

  17. [The development of endoscope workstation].

    PubMed

    Qi, L; Qi, L; Qiou, Q J; Yu, Q L

    2001-01-01

    This paper introduces an endoscope workstation, which solved the weak points of multimedia endoscope database used by most hospitals. The endoscope workstation was built on pedal-switch and NTFS file system. This paper also Introduces how to make program optimal and quick inputting. The workstation has promoted the efficiency of the doctor's operation.

  18. Endoscopic mucosal resection of colonic lesions: current applications and future prospects.

    PubMed

    Poppers, David M; Haber, Gregory B

    2008-05-01

    The introduction of submucosal fluid injection has remarkably extended the range of endoscopically resectable polyps. The limiting factor for endoscopic resection is not polyp size, but polyp depth. Endoscopic ultrasound is a useful adjunctive diagnostic tool to assess the depth of invasion. The success of are section ultimately depends on pathologic confirmation of a benign nature of this lesion or of a cancer limited to the mucosa. Selected well-differentiated cancers without lymphovascular invasion of the superficial submucosa can be successfully resected endoscopically.

  19. Endoscopic full-thickness resection: Current status

    PubMed Central

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-01-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices. PMID:26309354

  20. Endoscopic full-thickness resection: Current status.

    PubMed

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-08-21

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices.

  1. Endoscopic optical coherence tomography: technologies and clinical applications [Invited

    PubMed Central

    Gora, Michalina J.; Suter, Melissa J.; Tearney, Guillermo J.; Li, Xingde

    2017-01-01

    In this paper, we review the current state of technology development and clinical applications of endoscopic optical coherence tomography (OCT). Key design and engineering considerations are discussed for most OCT endoscopes, including side-viewing and forward-viewing probes, along with different scanning mechanisms (proximal-scanning versus distal-scanning). Multi-modal endoscopes that integrate OCT with other imaging modalities are also discussed. The review of clinical applications of endoscopic OCT focuses heavily on diagnosis of diseases and guidance of interventions. Representative applications in several organ systems are presented, such as in the cardiovascular, digestive, respiratory, and reproductive systems. A brief outlook of the field of endoscopic OCT is also discussed. PMID:28663882

  2. Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography.

    PubMed

    Herz, P R; Chen, Y; Aguirre, A D; Schneider, K; Hsiung, P; Fujimoto, J G; Madden, K; Schmitt, J; Goodnow, J; Petersen, C

    2004-10-01

    A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-microm axial resolution by use of a femtosecond Cr:forsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

  3. Endoscopic findings following retroperitoneal pancreas transplantation.

    PubMed

    Pinchuk, Alexey V; Dmitriev, Ilya V; Shmarina, Nonna V; Teterin, Yury S; Balkarov, Aslan G; Storozhev, Roman V; Anisimov, Yuri A; Gasanov, Ali M

    2017-07-01

    An evaluation of the efficacy of endoscopic methods for the diagnosis and correction of surgical and immunological complications after retroperitoneal pancreas transplantation. From October 2011 to March 2015, 27 patients underwent simultaneous retroperitoneal pancreas-kidney transplantation (SPKT). Diagnostic oesophagogastroduodenoscopy (EGD) with protocol biopsy of the donor and recipient duodenal mucosa and endoscopic retrograde pancreatography (ERP) were performed to detect possible complications. Endoscopic stenting of the main pancreatic duct with plastic stents and three-stage endoscopic hemostasis were conducted to correct the identified complications. Endoscopic methods showed high efficiency in the timely diagnosis and adequate correction of complications after retroperitoneal pancreas transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Endoscopic Therapy in Crohn's Disease: Principle, Preparation, and Technique.

    PubMed

    Chen, Min; Shen, Bo

    2015-09-01

    Stricture and fistula are common complications of Crohn's disease. Endoscopic balloon dilation and needle-knife stricturotomy has become a valid treatment option for Crohn's disease-associated strictures. Endoscopic therapy is also increasingly used in Crohn's disease-associated fistula. Preprocedural preparations, including routine laboratory testing, imaging examination, anticoagulant management, bowel cleansing and proper sedation, are essential to ensure a successful and safe endoscopic therapy. Adverse events, such as perforation and excessive bleeding, may occur during endoscopic intervention. The endoscopist should be well trained, always be cautious, anticipate for possible procedure-associated complications, be prepared for damage control during endoscopy, and have surgical backup ready. In this review, we discuss the principle, preparation, techniques of endoscopic therapy, as well as the prevention and management of endoscopic procedure-associated complications. We propose that inflammatory bowel disease endoscopy may be a part of training for "super" gastroenterology fellows, i.e., those seeking a career in advanced endoscopy or in inflammatory bowel disease.

  5. Endoscopic versus open bursectomy of lateral malleolar bursitis.

    PubMed

    Choi, Jae Hyuck; Lee, Kyung Tai; Lee, Young Koo; Kim, Dong Hyun; Kim, Jeong Ryoul; Chung, Woo Chull; Cha, Seung Do

    2012-06-01

    Compare the result of endoscopic versus open bursectomy in lateral malleolar bursitis. Prospective evaluation of 21 patients (22 ankles) undergoing either open or endoscopic excision of lateral malleolar bursitis. The median age was 64 (38-79) years old. The median postoperative follow-up was 15 (12-18) months. Those patients undergoing endoscopic excision showed a higher satisfaction rate (excellent 9, good 2) than open excision (excellent 4, good 3, fair 1). The wounds also healed earlier in the endoscopic group although the operation time was slightly longer. One patient in the endoscopic group had recurrence of symptoms but complications in the open group included one patient with skin necrosis, one patient with wound dehiscence, and two patients of with superficial peroneal nerve injury. Endoscopic resection of the lateral malleolar bursitis is a promising technique and shows favorable results compared to the open resection. Therapeutic studies-Investigating the result of treatment, Level II.

  6. Endoscopic Management of Tumor Bleeding from Inoperable Gastric Cancer

    PubMed Central

    Kim, Young-Il

    2015-01-01

    Tumor bleeding is not a rare complication in patients with inoperable gastric cancer. Endoscopy has important roles in the diagnosis and primary treatment of tumor bleeding, similar to its roles in other non-variceal upper gastrointestinal bleeding cases. Although limited studies have been performed, endoscopic therapy has been highly successful in achieving initial hemostasis. One or a combination of endoscopic therapy modalities, such as injection therapy, mechanical therapy, or ablative therapy, can be used for hemostasis in patients with endoscopic stigmata of recent hemorrhage. However, rebleeding after successful hemostasis with endoscopic therapy frequently occurs. Endoscopic therapy may be a treatment option for successfully controlling this rebleeding. Transarterial embolization or palliative surgery should be considered when endoscopic therapy fails. For primary and secondary prevention of tumor bleeding, proton pump inhibitors can be prescribed, although their effectiveness to prevent bleeding remains to be investigated. PMID:25844339

  7. Transmission of Infection by Flexible Gastrointestinal Endoscopy and Bronchoscopy

    PubMed Central

    Peters, Frans T. M.; van der Mei, Henny C.; Degener, John E.

    2013-01-01

    SUMMARY Flexible endoscopy is a widely used diagnostic and therapeutic procedure. Contaminated endoscopes are the medical devices frequently associated with outbreaks of health care-associated infections. Accurate reprocessing of flexible endoscopes involves cleaning and high-level disinfection followed by rinsing and drying before storage. Most contemporary flexible endoscopes cannot be heat sterilized and are designed with multiple channels, which are difficult to clean and disinfect. The ability of bacteria to form biofilms on the inner channel surfaces can contribute to failure of the decontamination process. Implementation of microbiological surveillance of endoscope reprocessing is appropriate to detect early colonization and biofilm formation in the endoscope and to prevent contamination and infection in patients after endoscopic procedures. This review presents an overview of the infections and cross-contaminations related to flexible gastrointestinal endoscopy and bronchoscopy and illustrates the impact of biofilm on endoscope reprocessing and postendoscopic infection. PMID:23554415

  8. Endoscopic methods in the treatment of early-stage esophageal cancer

    PubMed Central

    2014-01-01

    Most patients with early esophageal cancer restricted to the mucosa may be offered endoscopic therapy, which is similarly effective, less invasive and less expensive than esophagectomy. Selection of appropriate relevant treatment and therapy methods should be performed at a specialized center with adequate facilities. The selection of an endoscopic treatment method for high-grade dysplasia and early-stage esophageal adenocarcinoma requires that tumor infiltration is restricted to the mucosa and that there is no neighboring lymph node metastasis. In squamous cell carcinoma, this treatment method is accepted in cases of tumors invading only up to the lamina propria of mucosa (m2). Tumors treated with the endoscopic method should be well or moderately differentiated and should not invade lymphatic or blood vessels. When selecting endoscopic treatments for these lesions, a combination of endoscopic resection and endoscopic ablation methods should be considered. PMID:25097676

  9. A high definition Mueller polarimetric endoscope for tissue characterisation (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Qi, Ji; Elson, Daniel

    2016-03-01

    The mechanism of most medical endoscopes is based on the interaction between light and biological tissue, inclusive of absorption, elastic scattering and fluorescence. In essence, the metrics of those interactions are obtained from the fundamental properties of light as an electro-magnetic waves, namely, the radiation intensity and wavelength. As another fundamental property of light, polarisation can not only reveal tissue scattering and absorption information from a different perspective, but is also able to provide a fresh insight into directional tissue birefringence properties induced by birefringent compositions and anisotropic fibrous structures, such as collagen, elastin, muscle fibre, etc at the same time. Here we demonstrate a low cost high definition Muller polarimetric endoscope with minimal alteration of a rigid endoscope. By imaging birefringent tissue mimicking phantoms and a porcine bladder, we show that this novel endoscopic imaging modality is able to provide different information of interest from unpolarised endoscopic imaging, including linear depolarization, circular depolarization, birefringence, optic axis orientation and dichroism. This endoscope can potentially be employed for better tissue visualisation and benefit endoscopic investigations and intra-operative guidance.

  10. Endoscopic Evacuation of Subdural Collections.

    PubMed

    Boyaci, Suat; Gumustas, Oguzhan Guven; Korkmaz, Serdar; Aksoy, Kaya

    2016-01-01

    Intraoperative use of the endoscope is a hot topic in neurosurgery and it gives broader visualization of critical and hardlyreached areas. Endoscope-assisted surgical approach to chronic subdural haematoma (SDH) is a minimally invasive technique and may give an expansion to the regular method of burr-hole haematoma drainage. Endoscope-assisted haematoma drainage with mini-craniotomy was performed over a 24-month period, and prospectively collected data is reviewed. A total of 10 procedures (8 patients) were performed using the endoscopeassisted technique. Four of them were chronic SDH and six were subacute SDH. Procedures were extended 20 minutes in average because of endoscopic intervention. There was no extra-morbidity through the study as a consequence of endoscopic assessment. Endoscope-assisted techniques can make the operation safe in selected circumstances with improved intraoperative visualization. It may likewise take into consideration the identification and destruction of neo-membranes, septums and solid clots. In addition, the source of bleeding can be easily coagulated. The endoscope-assisted techniques, with all of these features, can alter the pre- and intra-operative decision-making for selected patients.

  11. The Correlation of Endoscopic Findings and Clinical Features in Korean Patients with Scrub Typhus: A Cohort Study.

    PubMed

    Lee, Jun; Kim, Dong-Min; Yun, Na Ra; Kim, Young Dae; Park, Chan Guk; Kim, Man Woo

    2016-01-01

    Scrub typhus is an infectious disease caused by Orientia tsutsugamushi-induced systemic vasculitis, but the involvement of the gastrointestinal tract and the endoscopic findings associated with scrub typhus are not well understood. We performed a prospective study and recommend performing esophagogastroduodenoscopy (EGD) for all possible scrub typhus patients, regardless of gastrointestinal symptoms. Gastrointestinal symptoms, endoscopic findings and clinical severity based on organ involvement and ICU admission were analyzed. Gastrointestinal symptoms occurred in up to 76.4% of scrub typhus patients. The major endoscopic findings were ulcers (43/127, 33.9%). Interestingly, 7.1% (9/127) of the patients presented with esophageal candidiasis. There was no correlation between the presence or absence of gastrointestinal symptoms and the endoscopic grade (P = 0.995). However, there was a positive correlation between the clinical severity and the endoscopic findings (P = 0.001). Sixty-three percent of the patients presented with erosion or ulcers on prospectively performed endoscopic evaluations, irrespective of gastrointestinal symptoms. Gastrointestinal symptoms did not reflect the need for endoscopy. Scrub typhus patients could have significant endoscopic abnormalities even in the absence of gastrointestinal symptoms.

  12. Endoscopic therapy of neoplasia related to Barrett's esophagus and endoscopic palliation of esophageal cancer.

    PubMed

    Vignesh, Shivakumar; Hoffe, Sarah E; Meredith, Kenneth L; Shridhar, Ravi; Almhanna, Khaldoun; Gupta, Akshay K

    2013-04-01

    Barrett's esophagus (BE) is the most important identifiable risk factor for the progression to esophageal adenocarcinoma. This article reviews the current endoscopic therapies for BE with high-grade dysplasia and intramucosal cancer and briefly discusses the endoscopic palliation of advanced esophageal cancer. The diagnosis of low-grade or high-grade dysplasia (HGD) is based on several cytologic criteria that suggest neoplastic transformation of the columnar epithelium. HGD and carcinoma in situ are regarded as equivalent. The presence of dysplasia, particularly HGD, is also a risk factor for synchronous and metachronous adenocarcinoma. Dysplasia is a marker of adenocarcinoma and also has been shown to be the preinvasive lesion. Esophagectomy has been the conventional treatment for T1 esophageal cancer and, although debated, is an appropriate option in some patients with HGD due to the presence of occult cancer in over one-third of patients. Endoscopic ablative modalities (eg, photodynamic therapy and cryoablation) and endoscopic resection techniques (eg, endoscopic mucosal resection) have demonstrated promising results. The significant morbidity and mortality of esophagectomy makes endoscopic treatment an attractive potential option.

  13. Patient Response to Endoscopic Therapy for Gastroesophageal Varices Based on Endoscopic Ultrasound Findings.

    PubMed

    Tseng, Yujen; Ma, Lili; Luo, Tiancheng; Zeng, Xiaoqing; Li, Feng; Li, Na; Wei, Yichao; Chen, Shiyao

    2018-04-27

    Gastroesophageal variceal hemorrhage is a common complication of portal hypertension. Endoscopic therapy is currently recommended for preventing gastroesophageal variceal rebleed. However, the rate of variceal rebleed and its associated mortality remain concerning. This study is aimed at differentiating patient response to endoscopic therapy based on endoscopic ultrasound (EUS) findings. One-hundred seventy patients previously treated with repeat endoscopic therapy for secondary prophylaxis were enrolled and classified into two groups based on treatment response. Prior to consolidation therapy, all patients received an EUS examination to observe for extraluminal phenomena. All available follow-up endoscopic examination records were retrieved to validate study results. Of the 170 subjects, 106 were poor responders, while 64 were good responders. The presence of para-gastric, gastric perforating, and esophageal perforating veins was associated with poor patient response (p<0.001). The odds ratio for para-gastric veins was 5.374. Follow-up endoscopic findings for poor responders with incomplete variceal obliteration was closely correlated with the presence of para-gastric veins (p=0.002). The presence of para-gastric veins is a characteristic of poor response to endoscopic therapy for treating gastroesophageal varices. Early identification of this subgroup necessitates a change in course of treatment to improve overall patient outcome.

  14. Balancing the shortcomings of microscope and endoscope: endoscope-assisted technique in microsurgical removal of recurrent epidermoid cysts in the posterior fossa.

    PubMed

    Ebner, F H; Roser, F; Thaher, F; Schittenhelm, J; Tatagiba, M

    2010-10-01

    We report about endoscope-assisted surgery of epidermoid cysts in the posterior fossa focusing on the application of neuro-endoscopy and the clinical outcome in cases of recurrent epidermoid cysts. 25 consecutively operated patients with an epidermoid cyst in the posterior fossa were retrospectively analysed. Surgeries were performed both with an operating microscope (OPMI Pentero or NC 4, Zeiss Company, Oberkochen, Germany) and endoscopic equipment (4 mm rigid endoscopes with 30° and 70° optics; Karl Storz Company, Tuttlingen, Germany) under continuous intraoperative monitoring. Surgical reports and DVD-recordings were evaluated for identification of adhesion areas and surgical details. 7 (28%) of the 25 patients were recurrences of previously operated epidermoid cysts. Mean time to recurrence was 17 years (8-22 years). In 5 cases the endoscope was used as an adjunctive tool for inspection/endoscope-assisted removal of remnants. The effective time of use of the endoscope was limited to the end stage of the procedure, but was very effective. In a modern operative setting and with the necessary surgical experience recurrent epidermoid cysts may be removed with excellent clinical results. The combined use of microscope and endoscope offers relevant advantages in demanding anatomic situations. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Endoscopic techniques in aesthetic plastic surgery.

    PubMed

    McCain, L A; Jones, G

    1995-01-01

    There has been an explosive interest in endoscopic techniques by plastic surgeons over the past two years. Procedures such as facial rejuvenation, breast augmentation and abdominoplasty are being performed with endoscopic assistance. Endoscopic operations require a complex setup with components such as video camera, light sources, cables and hard instruments. The Hopkins Rod Lens system consists of optical fibers for illumination, an objective lens, an image retrieval system, a series of rods and lenses, and an eyepiece for image collection. Good illumination of the body cavity is essential for endoscopic procedures. Placement of the video camera on the eyepiece of the endoscope gives a clear, brightly illuminated large image on the monitor. The video monitor provides the surgical team with the endoscopic image. It is important to become familiar with the equipment before actually doing cases. Several options exist for staff education. In the operating room the endoscopic cart needs to be positioned to allow a clear unrestricted view of the video monitor by the surgeon and the operating team. Fogging of the endoscope may be prevented during induction by using FREDD (a fog reduction/elimination device) or a warm bath. The camera needs to be white balanced. During the procedure, the nurse monitors the level of dissection and assesses for clogging of the suction.

  16. Predictive Factors of Atelectasis Following Endoscopic Resection.

    PubMed

    Choe, Jung Wan; Jung, Sung Woo; Song, Jong Kyu; Shim, Euddeum; Choo, Ji Yung; Kim, Seung Young; Hyun, Jong Jin; Koo, Ja Seol; Yim, Hyung Joon; Lee, Sang Woo

    2016-01-01

    Atelectasis is one of the pulmonary complications associated with anesthesia. Little is known about atelectasis following endoscopic procedures under deep sedation. This study evaluated the frequency, risk factors, and clinical course of atelectasis after endoscopic resection. A total of 349 patients who underwent endoscopic resection of the upper gastrointestinal tract at a single academic tertiary referral center from March 2010 to October 2013 were enrolled. Baseline characteristics and clinical data were retrospectively reviewed from medical records. To identify atelectasis, we compared the chest radiography taken before and after the endoscopic procedure. Among the 349 patients, 68 (19.5 %) had newly developed atelectasis following endoscopic resection. In univariate logistic regression analysis, atelectasis correlated significantly with high body mass index, smoking, diabetes mellitus, procedure duration, size of lesion, and total amount of propofol. In multiple logistic regression analysis, body mass index, procedure duration, and total propofol amount were risk factors for atelectasis following endoscopic procedures. Of the 68 patients with atelectasis, nine patients developed fever, and six patients displayed pneumonic infiltration. The others had no symptoms related to atelectasis. The incidence of radiographic atelectasis following endoscopic resection was nearly 20 %. Obesity, procedural time, and amount of propofol were the significant risk factors for atelectasis following endoscopic procedure. Most cases of the atelectasis resolved spontaneously with no sequelae.

  17. Quantitative ENT endoscopy: the future in the new millennium

    NASA Astrophysics Data System (ADS)

    Mueller, Andreas; Schubert, Mario

    1999-06-01

    In Otorhinolaryngology the endoscopic appraisal of luminal dimensions of the nose, the throat, the larynx and the trachea is a daily problem. Those concerned with endoscopy know, that endoscopes distort dimensions of examined anatomical structures. To draw conclusions on luminal dimensions from the endoscopic pictures additional measuring devices are required. We developed a new method of measuring luminal dimensions in rigid or flexible endoscopy. For this a laser beam directed radially marks the anatomical lumen of interest in the videoendoscopic vision. The laser ring becomes deformed according to the form of the cavity explored. By keeping the distance defined between the laser ring and the top of the endoscope, the endoscopic video image can be measured. A piece of software developed by us calculates from the pictures the cross sectional area as well as the extension of benign or malign stenosis of the cavity explored. The result of the endoscopic measuring procedure can be visualized 3D on a PC-monitor. We are going to demonstrate the result of our clinical experience in different otorhinolaryngological diseases with the new endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic assisted manufacturing (EAM) of anatomical adapted stents, tubes and cannules.

  18. Endoscopic management of sinonasal hemangiopericytoma.

    PubMed

    Tessema, Belachew; Eloy, Jean Anderson; Folbe, Adam J; Anstead, Amy S; Mirani, Neena M; Jourdy, Deya N; Joudy, Deya N; Ruiz, Jose W; Casiano, Roy R

    2012-03-01

    Sinonasal hemangiopericytomas (SNHPCs) are rare perivascular tumors with low-grade malignant potential. Traditionally, these tumors have been treated with open approaches such as lateral rhinotomy, Caldwell-Luc, or transfacial approaches. Increased experience with endoscopic management of benign and malignant sinonasal tumors has led to a shift in management of SNHPC. The authors present their experience in the largest series of patients with SNHPC managed endoscopically. Case series at a tertiary care medical center. A retrospective chart review of all patients undergoing endoscopic management of SNHPC at the University of Miami between 1999 and 2008 was conducted. All endoscopic resections were performed with curative intent. Twelve patients with the diagnosis of SNHPC were treated endoscopically. Mean age was 62.5 years (range, 51-83 years). There were 6 men and 6 women. The mean follow-up was 41 months (range, 15-91 months). Seven (58.3%) presented with nasal obstruction, whereas 4 (41.6%) had epistaxis as their initial presenting symptom. Preoperative angiography or embolization was not performed in any case. Mean estimated blood loss was 630 mL (range, 100-1500 mL). Six patients underwent endonasal endoscopic anterior skull base resection; 4 had complete endoscopic resection all with negative margins. None underwent postoperative adjuvant treatment. No recurrence or metastatic disease was observed in this patient population. Endoscopic management of SNHPC is a feasible approach and did not compromise outcomes in this experience. In this series, familiarity with advance endoscopic sinus surgery was necessary to manage these patients. Postoperative adjuvant therapy was not necessary in this cohort.

  19. Intraventricular and skull base neuroendoscopy in 2012: a global survey of usage patterns and the role of intraoperative neuronavigation.

    PubMed

    Esposito, Felice; Di Rocco, Federico; Zada, Gabriel; Cinalli, Giuseppe; Schroeder, Henry W S; Mallucci, Conor; Cavallo, Luigi M; Decq, Philippe; Chiaramonte, Carmela; Cappabianca, Paolo

    2013-12-01

    During the past decade, endoscopic intraventricular and skull base operations have become widely used for a variety of evolving indications. A global survey of practicing endoscopic neurosurgeons was performed to characterize patterns of usage regarding endoscopy equipment, instrumentation, and the indications for using image-guided surgery systems (IGSs). An online survey consisting of 8 questions was completed by 235 neurosurgeons with endoscopic surgical experience. Responses were entered into a database and subsequently analyzed. The median number of operations performed per year by intraventricular and skull base endoscopic surgeons was 27 and 25, respectively. Data regarding endoscopic equipment brand, diameter, and length are presented. The most commonly reported indications for IGSs during intraventricular endoscopic surgery were tumor biopsy/resection, intraventricular cyst fenestration, septostomy/pellucidotomy, endoscopic third ventriculostomy, and aqueductal stent placement. Intraventricular surgeons reported using IGSs for all cases in 16.6% and never in 24.4%. Overall, endoscopic skull base surgeons reported using IGSs for all cases in 23.9% and never in 18.9%. The most commonly reported indications for IGSs during endoscopic skull base operations were complex sinus/skull base anatomy, extended approaches, and reoperation. Many variations and permutations for performing intraventricular and skull base endoscopic surgery exist worldwide. Much can be learned by studying the patterns and indications for using various types of equipment and operative adjuncts such as IGSs. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Predictors for the need for endoscopic therapy in patients with presumed acute upper gastrointestinal bleeding.

    PubMed

    Kim, Su Sun; Kim, Kyung Up; Kim, Sung Jun; Seo, Seung In; Kim, Hyoung Su; Jang, Myoung Kuk; Kim, Hak Yang; Shin, Woon Geon

    2017-12-15

    Selecting patients with an urgent need for endoscopic hemostasis is difficult based only on simple parameters of presumed acute upper gastrointestinal bleeding. This study assessed easily applicable factors to predict cases in need of urgent endoscopic hemostasis due to acute upper gastrointestinal bleeding. The consecutively included patients were divided into the endoscopic hemostasis and nonendoscopic hemostasis groups. We reviewed the enrolled patients' medical records and analyzed various variables and parameters for acute upper gastrointestinal bleeding outcomes such as demographic factors, comorbidities, symptoms, signs, laboratory findings, rebleeding rate, and mortality to evaluate simple predictive factors for endoscopic treatment. A total of 613 patients were analyzed, including 329 patients in the endoscopic hemostasis and 284 patients in the non-endoscopic hemostasis groups. In the multivariate analysis, a bloody nasogastric lavage (adjusted odds ratio [AOR], 6.786; 95% confidence interval [CI], 3.990 to 11.543; p < 0.0001) and a hemoglobin level less than 8.6 g/dL (AOR, 1.768; 95% CI, 1.028 to 3.039; p = 0.039) were independent predictors for endoscopic hemostasis. Significant differences in the morbidity rates of endoscopic hemostasis were detected between the group with no predictive factors and the group with one or more predictive factors (OR, 2.677; 95% CI, 1.920 to 3.733; p < 0.0001). A bloody nasogastric lavage and hemoglobin < 8.6 g/dL were independent predictors of endoscopic hemostasis in patients with acute upper gastrointestinal bleeding.

  1. Identification of early cancerous lesion of esophagus with endoscopic images by hyperspectral image technique (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Huang, Shih-Wei; Chen, Shih-Hua; Chen, Weichung; Wu, I.-Chen; Wu, Ming Tsang; Kuo, Chie-Tong; Wang, Hsiang-Chen

    2016-03-01

    This study presents a method to identify early esophageal cancer within endoscope using hyperspectral imaging technology. The research samples are three kinds of endoscopic images including white light endoscopic, chromoendoscopic, and narrow-band endoscopic images with different stages of pathological changes (normal, dysplasia, dysplasia - esophageal cancer, and esophageal cancer). Research is divided into two parts: first, we analysis the reflectance spectra of endoscopic images with different stages to know the spectral responses by pathological changes. Second, we identified early cancerous lesion of esophagus by principal component analysis (PCA) of the reflectance spectra of endoscopic images. The results of this study show that the identification of early cancerous lesion is possible achieve from three kinds of images. In which the spectral characteristics of NBI endoscopy images of a gray area than those without the existence of the problem the first two, and the trend is very clear. Therefore, if simply to reflect differences in the degree of spectral identification, chromoendoscopic images are suitable samples. The best identification of early esophageal cancer is using the NBI endoscopic images. Based on the results, the use of hyperspectral imaging technology in the early endoscopic esophageal cancer lesion image recognition helps clinicians quickly diagnose. We hope for the future to have a relatively large amount of endoscopic image by establishing a hyperspectral imaging database system developed in this study, so the clinician can take this repository more efficiently preliminary diagnosis.

  2. Magnetic control system targeted for capsule endoscopic operations in the stomach--design, fabrication, and in vitro and ex vivo evaluations.

    PubMed

    Lien, Gi-Shih; Liu, Chih-Wen; Jiang, Joe-Air; Chuang, Cheng-Long; Teng, Ming-Tsung

    2012-07-01

    This paper presents a novel solution of a hand-held external controller to a miniaturized capsule endoscope in the gastrointestinal (GI) tract. Traditional capsule endoscopes move passively by peristaltic wave generated in the GI tract and the gravity, which makes it impossible for endoscopists to manipulate the capsule endoscope to the diagnostic disease areas. In this study, the main objective is to present an endoscopic capsule and a magnetic field navigator (MFN) that allows endoscopists to remotely control the locomotion and viewing angle of an endoscopic capsule. The attractive merits of this study are that the maneuvering of the endoscopic capsule can be achieved by the external MFN with effectiveness, low cost, and operation safety, both from a theoretical and an experimental point of view. In order to study the magnetic interactions between the endoscopic capsule and the external MFN, a magnetic-analysis model is established for computer-based finite-element simulations. In addition, experiments are conducted to show the control effectiveness of the MFN to the endoscopic capsule. Finally, several prototype endoscopic capsules and a prototype MFN are fabricated, and their actual capabilities are experimentally assessed via in vitro and ex vivo tests using a stomach model and a resected porcine stomach, respectively. Both in vitro and ex vivo test results demonstrate great potential and practicability of achieving high-precision rotation and controllable movement of the capsule using the developed MFN.

  3. Novel endoscopic delivery modality of infrared coagulation therapy for internal hemorrhoids.

    PubMed

    McLemore, Elisabeth C; Rai, Rudra; Siddiqui, Junaid; Basu, P Patrick; Tabbaa, Mousab; Epstein, Michael S

    2012-11-01

    A novel endoscopic delivery system for infrared coagulation therapy (IRC) has been designed recently. IRC is a well-established treatment for symptomatic internal hemorrhoids. Patients frequently undergo lower endoscopy before hemorrhoid treatment to eliminate other sources of bleeding. Current treatment options are difficult to perform without an anal retractor, adequate lighting, and specialized instruments. Endoscopic IRC is an attractive alternative to standard IRC, because it can be performed during the lower endoscopy. Endoscopic IRC utilizes infrared radiation generated by a control box, which is applied to the tissue through a flexible, fiber optic light guide (Precision Endoscopic Infrared Coagulator™). The light guide is placed through the colonoscope or flexible sigmoidoscope in the same chamber as other endoscopic instruments. A retrospective review was performed using a prospectively collected database. A standardized protocol was utilized in all patients. Patients graded their symptoms before and after therapy by using the visual analog symptom severity scoring system (range, 0-10). These results were analyzed by using the nonparametric Wilcoxon signed-rank test. Exact P values were computed by using the R function wilcox.exact. A total of 55 patients underwent endoscopic IRC for predominately grade II and grade III symptomatic internal hemorrhoids (71 %). There were 22 (40 %) female patients. Posttherapy results indicated a significant improvement in global symptoms (pretreatment average global score = 2.24 vs. posttreatment average global score = 0.28; P < 0.0001). There have been no adverse events reported to date. Endoscopic IRC provides improved visibility and efficiency, allowing simultaneous treatment of symptomatic internal hemorrhoids at the time of lower endoscopy. Patients experienced significant improvement in their symptoms after a single session of endoscopic IRC. There are a variety of additional endoscopic IRC therapeutic utilities: endoscopic management of angiodysplasia, inflammation, hemostasis, and NOTES applications.

  4. Surgical management of bilateral vocal fold paralysis: A cost-effectiveness comparison of two treatments.

    PubMed

    Naunheim, Matthew R; Song, Phillip C; Franco, Ramon A; Alkire, Blake C; Shrime, Mark G

    2017-03-01

    Endoscopic management of bilateral vocal fold paralysis (BVFP) includes cordotomy and arytenoidectomy, and has become a well-accepted alternative to tracheostomy. However, the costs and quality-of-life benefits of endoscopic management have not been examined with formal economic analysis. This study undertakes a cost-effectiveness analysis of tracheostomy versus endoscopic management of BVFP. Cost-effectiveness analysis. A literature review identified a range of costs and outcomes associated with surgical options for BVFP. Additional costs were derived from Medicare reimbursement data; all were adjusted to 2014 dollars. Cost-effectiveness analysis evaluated both therapeutic strategies in short-term and long-term scenarios. Probabilistic sensitivity analysis was used to assess confidence levels regarding the economic evaluation. The incremental cost effectiveness ratio for endoscopic management versus tracheostomy is $31,600.06 per quality-adjusted life year (QALY), indicating that endoscopic management is the cost-effective short-term strategy at a willingness-to-pay (WTP) threshold of $50,000/QALY. The probability that endoscopic management is more cost-effective than tracheostomy at this WTP is 65.1%. Threshold analysis demonstrated that the model is sensitive to both utilities and cost in the short-term scenario. When costs of long-term care are included, tracheostomy is dominated by endoscopic management, indicating the cost-effectiveness of endoscopic management at any WTP. Endoscopic management of BVFP appears to be more cost-effective than tracheostomy. Though endoscopic cordotomy and arytenoidectomy require expertise and specialized equipment, this model demonstrates utility gains and long-term cost advantages to an endoscopic strategy. These findings are limited by the relative paucity of robust utility data and emphasize the need for further economic analysis in otolaryngology. NA Laryngoscope, 127:691-697, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Primary and revision efficacy of cross-wired metallic stents for endoscopic bilateral stent-in-stent placement in malignant hilar biliary strictures.

    PubMed

    Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J

    2013-01-01

    Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Endoscopic traversability in patients with locally advanced esophageal squamous cell carcinoma: Is it a significant prognostic factor?

    PubMed

    Shin, Hae Jin; Moon, Hee Seok; Kang, Sun Hyung; Sung, Jae Kyu; Jeong, Hyun Yong; Kim, Seok Hyun; Lee, Byung Seok; Kim, Ju Seok; Yun, Gee Young

    2017-12-01

    The purpose of this study was to evaluate the prognostic impact of endoscopic traversability in patients with locally advanced esophageal squamous cell carcinoma.This retrospective study was based on medical records from a single tertiary medical center. The records of 317 patients with esophageal squamous cell carcinoma treated with surgery or definitive chemoradiotherapy (CRT) between January 2009 and March 2016 were reviewed. Finally, we retrieved the data on 168 consecutive patients. These 168 patients were divided into 2 groups based on their endoscopic traversability findings: Group A (the endoscope traversable group), and Group B (the endoscope non-traversable group). We then retrospectively compared the clinical characteristics of these 2 groups.The endoscope non-traversable group (Group B) revealed an advanced clinical stage, a poor Eastern Cooperative Oncology Group (ECOG) score, a lower serum albumin level, a higher rate of requirement for esophageal stent insertion and definitive CRT as initial treatment than the endoscope traversable group (Group A). Patients with endoscope traversable cancer showed a significantly higher 3-year overall survival and 3-year relapse-free survival than patients who were endoscope non-traversable (53.8% vs 17.3%, P < .001 and 71.1% vs 45.3%, P = .003, respectively). Upon multivariate analysis of patients with locally advanced esophageal squamous cell carcinoma treated with definitive CRT, the serum albumin level <3.5 g/dL and endoscopic non-traversability were significant negative factors of survival.Endoscopic traversability in patients with locally advanced esophageal squamous cell carcinoma treated with definitive CRT is a significant prognostic factor. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  7. A Novel Protocol Obviates Endoscope Sampling for Carbapenem-Resistant Enterobacteriaceae: Experience of a Center with a Prior Outbreak.

    PubMed

    Smith, Zachary L; Dua, Arshish; Saeian, Kia; Ledeboer, Nathan A; Graham, Mary Beth; Aburajab, Murad; Ballard, Darren D; Khan, Abdul H; Dua, Kulwinder S

    2017-11-01

    Numerous published outbreaks, including one from our institution, have described endoscope-associated transmission of multidrug-resistant organisms (MDROs). Individual centers have adopted their own protocols to address this issue, including endoscope culture and sequestration. Endoscope culturing has drawbacks and may allow residual bacteria, including MDROs, to go undetected after high-level disinfection. To report the outcome of our novel protocol, which does not utilize endoscope culturing, to address our outbreak. All patients undergoing procedures with elevator-containing endoscopes were asked to permit performance of a rectal swab. All endoscopes underwent high-level disinfection according to updated manufacturer's guidance. Additionally, ethylene oxide (EtO) sterilization was done in the high-risk settings of (1) positive response to a pre-procedure risk stratification questionnaire, (2) positive or indeterminate CRE polymerase chain reaction (PCR) from rectal swab, (3) refusal to consent for PCR or questionnaire, (4) purulent cholangitis or infected pancreatic fluid collections. Two endoscopes per weekend were sterilized on a rotational basis. From September 1, 2015 to April 30, 2016, 556 endoscopy sessions were performed using elevator-containing endoscopes. Prompted EtO sterilization was done on 46 (8.3%) instances, 3 from positive/indeterminate PCR tests out of 530 samples (0.6%). No CRE transmission was observed during the study period. Damage or altered performance of endoscopes related to EtO was not observed. In this pilot study, prompted EtO sterilization in high-risk patients has thus far eliminated endoscope-associated MDRO transmission, although no CRE infections were noted throughout the institution during the study period. Further studies and a larger patient sample will be required to validate these findings.

  8. High-quality endoscope reprocessing decreases endoscope contamination.

    PubMed

    Decristoforo, P; Kaltseis, J; Fritz, A; Edlinger, M; Posch, W; Wilflingseder, D; Lass-Flörl, C; Orth-Höller, D

    2018-02-24

    Several outbreaks of severe infections due to contamination of gastrointestinal (GI) endoscopes, mainly duodenoscopes, have been described. The rate of microbial endoscope contamination varies dramatically in literature. The aim of this multicentre prospective study was to evaluate the hygiene quality of endoscopes and automated endoscope reprocessors (AERs) in Tyrol/Austria. In 2015 and 2016, a total of 463 GI endoscopes and 105 AERs from 29 endoscopy centres were analysed by a routine (R) and a combined routine and advanced (CRA) sampling procedure and investigated for microbial contamination by culture-based and molecular-based analyses. The contamination rate of GI endoscopes was 1.3%-4.6% according to the national guideline, suggesting that 1.3-4.6 patients out of 100 could have had contacts with hygiene-relevant microorganisms through an endoscopic intervention. Comparison of R and CRA sampling showed 1.8% of R versus 4.6% of CRA failing the acceptance criteria in phase I and 1.3% of R versus 3.0% of CRA samples failing in phase II. The most commonly identified indicator organism was Pseudomonas spp., mainly Pseudomonas oleovorans. None of the tested viruses were detected in 40 samples. While AERs in phase I failed (n = 9, 17.6%) mainly due to technical faults, phase II revealed lapses (n = 6, 11.5%) only on account of microbial contamination of the last rinsing water, mainly with Pseudomonas spp. In the present study the contamination rate of endoscopes was low compared with results from other European countries, possibly due to the high quality of endoscope reprocessing, drying and storage. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Role of follow-up endoscopic examination in treatment response assessment for patients with gastric diffuse large B cell lymphoma.

    PubMed

    Yoon, Seung Bae; Lee, In Seok; Lee, Ha Ni; Kim, Eunyoung; Kim, Woohyeon; Lee, Han Hee; Lee, Bo-In; Choi, Myung-Gyu; Jung, Seung Eun; Choi, Byung Ock; Park, Gyeong Sin; Cho, Seok-Goo

    2016-09-01

    According to lymphoma guidelines, gastric diffuse large B cell lymphoma (DLBCL) patients should undergo regular computed tomography (CT) and/or positron emission tomography (PET) examinations to assess treatment response. Endoscopic examinations are not indicated in the guidelines. The aim of this study was to investigate the utility of endoscopic examinations during and after treatment for DLBCL. We reviewed the patients diagnosed with gastric DLBCL at Seoul St. Mary's Hospital. All patients underwent endoscopy and radiologic examinations at every follow-up appointment. Radiologic response was defined according to World Health Organization criteria and endoscopic response was determined based on the Groupe d'Etude des Lymphomes de l'Adult grading system that is widely used in post-treatment evaluation of gastric MALT lymphoma. Forty-five patients were analyzed. Within a median follow-up period of 34 months, 35 patients achieved both radiologic and endoscopic complete remission (CR). The median times to endoscopic and radiologic CR were not significantly different (21 versus 16 weeks, p = 0.118). However, in 25 patients with stage I disease, endoscopic CR [median (range), 20 (11-36)] was achieved later than radiologic CR [median (range), 13 (8-36)] (p = 0.027). Among 40 patients who achieved radiologic CR, 35 patients who also achieved endoscopic CR maintained remission during the follow-up. Two of the five patients who achieved radiologic CR without endoscopic CR experienced recurrence. In gastric DLBCL patients, endoscopic response does not always correlate with radiologic response and might predict disease recurrence. We suggest that follow-up endoscopic examination with biopsy should be performed in addition to radiologic examination.

  10. A virtual reality endoscopic simulator augments general surgery resident cancer education as measured by performance improvement.

    PubMed

    White, Ian; Buchberg, Brian; Tsikitis, V Liana; Herzig, Daniel O; Vetto, John T; Lu, Kim C

    2014-06-01

    Colorectal cancer is the second most common cause of death in the USA. The need for screening colonoscopies, and thus adequately trained endoscopists, particularly in rural areas, is on the rise. Recent increases in required endoscopic cases for surgical resident graduation by the Surgery Residency Review Committee (RRC) further emphasize the need for more effective endoscopic training during residency to determine if a virtual reality colonoscopy simulator enhances surgical resident endoscopic education by detecting improvement in colonoscopy skills before and after 6 weeks of formal clinical endoscopic training. We conducted a retrospective review of prospectively collected surgery resident data on an endoscopy simulator. Residents performed four different clinical scenarios on the endoscopic simulator before and after a 6-week endoscopic training course. Data were collected over a 5-year period from 94 different residents performing a total of 795 colonoscopic simulation scenarios. Main outcome measures included time to cecal intubation, "red out" time, and severity of simulated patient discomfort (mild, moderate, severe, extreme) during colonoscopy scenarios. Average time to intubation of the cecum was 6.8 min for those residents who had not undergone endoscopic training versus 4.4 min for those who had undergone endoscopic training (p < 0.001). Residents who could be compared against themselves (pre vs. post-training), cecal intubation times decreased from 7.1 to 4.3 min (p < 0.001). Post-endoscopy rotation residents caused less severe discomfort during simulated colonoscopy than pre-endoscopy rotation residents (4 vs. 10%; p = 0.004). Virtual reality endoscopic simulation is an effective tool for both augmenting surgical resident endoscopy cancer education and measuring improvement in resident performance after formal clinical endoscopic training.

  11. Experience in colon sparing surgery in North America: advanced endoscopic approaches for complex colorectal lesions.

    PubMed

    Gorgun, Emre; Benlice, Cigdem; Abbas, Maher A; Steele, Scott

    2018-07-01

    Need for colon sparing interventions for premalignant lesions not amenable to conventional endoscopic excision has stimulated interest in advanced endoscopic approaches. The aim of this study was to report a single institution's experience with these techniques. A retrospective review was conducted of a prospectively collected database of all patients referred between 2011 and 2015 for colorectal resection of benign appearing deemed endoscopically unresectable by conventional endoscopic techniques. Patients were counseled for endoscopic submucosal dissection (ESD) with possible combined endoscopic-laparoscopic surgery (CELS) or alternatively colorectal resection if unable to resect endoscopically or suspicion for cancer. Lesion characteristic, resection rate, complications, and outcomes were evaluated. 110 patients were analyzed [mean age 64 years, female gender 55 (50%), median body mass index 29.4 kg/m 2 ]. Indications for interventions were large polyp median endoscopic size 3 cm (range 1.5-6.5) and/or difficult location [cecum (34.9%), ascending colon (22.7%), transverse colon (14.5%), hepatic flexure (11.8%), descending colon (6.3%), sigmoid colon (3.6%), rectum (3.6%), and splenic flexure (2.6%)]. Lesion morphology was sessile (N = 98, 93%) and pedunculated (N = 12, 7%). Successful endoscopic resection rate was 88.2% (N = 97): ESD in 69 patients and CELS in 28 patients. Complication rate was 11.8% (13/110) [delayed bleeding (N = 4), perforation (N = 3), organ-space surgical site infection (SSI) (N = 2), superficial SSI (N = 1), and postoperative ileus (N = 3)]. Out of 110 patients, 13 patients (11.8%) required colectomy for technical failure (7 patients) or carcinoma (6 patients). During a median follow-up of 16 months (range 6-41 months), 2 patients had adenoma recurrence. Advanced endoscopic surgery appears to be a safe and effective alternative to colectomy for patients with complex premalignant lesions deemed unresectable with conventional endoscopic techniques.

  12. TU-AB-202-12: A Novel Method to Map Endoscopic Video to CT for Treatment Planning and Toxicity Analysis in Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, W; Yang, J; Beadle, B

    Purpose: Endoscopic examinations are routine procedures for head-and-neck cancer patients. Our goal is to develop a method to map the recorded video to CT, providing valuable information for radiotherapy treatment planning and toxicity analysis. Methods: We map video frames to CT via virtual endoscopic images rendered at the real endoscope’s CT-space coordinates. We developed two complementary methods to find these coordinates by maximizing real-to-virtual image similarity:(1)Endoscope Tracking: moves the virtual endoscope frame-by-frame until the desired frame is reached. Utilizes prior knowledge of endoscope coordinates, but sensitive to local optima. (2)Location Search: moves the virtual endoscope along possible paths through themore » volume to find the desired frame. More robust, but more computationally expensive. We tested these methods on clay phantoms with embedded markers for point mapping and protruding bolus material for contour mapping, and we assessed them qualitatively on three patient exams. For mapped points we calculated 3D-distance errors, and for mapped contours we calculated mean absolute distances (MAD) from CT contours. Results: In phantoms, Endoscope Tracking had average point error=0.66±0.50cm and average bolus MAD=0.74±0.37cm for the first 80% of each video. After that the virtual endoscope got lost, increasing these values to 4.73±1.69cm and 4.06±0.30cm. Location Search had point error=0.49±0.44cm and MAD=0.53±0.28cm. Point errors were larger where the endoscope viewed the surface at shallow angles<10 degrees (1.38±0.62cm and 1.22±0.69cm for Endoscope Tracking and Location Search, respectively). In patients, Endoscope Tracking did not make it past the nasal cavity. However, Location Search found coordinates near the correct location for 70% of test frames. Its performance was best near the epiglottis and in the nasal cavity. Conclusion: Location Search is a robust and accurate technique to map endoscopic video to CT. Endoscope Tracking is sensitive to erratic camera motion and local optima, but could be used in conjunction with anchor points found using Location Search.« less

  13. Endoscopic medial maxillectomy breaking new frontiers.

    PubMed

    Mohanty, Sanjeev; Gopinath, M

    2013-07-01

    Endoscopy has changed the perspective of rhinologist towards the nose. It has revolutionised the surgical management of sinonasal disorders. Sinus surgeries were the first to get the benefit of endoscope. Gradually the domain of endoscopic surgery extended to the management of sino nasal tumours. Traditionally medial maxillectomy was performed through lateral rhinotomy or mid facial degloving approach. Endoscopic medial maxillectomy has been advocated by a number of authors in the management of benign sino-nasal tumours. We present our experience of endoscopic medial maxillectomy in the management of sinonasal pathologies.

  14. Supracerebellar Infratentorial Endoscopic and Endoscopic-Assisted Approaches to Pineal Lesions: Technical Report and Review of the Literature.

    PubMed

    Snyder, Rita; Felbaum, Daniel R; Jean, Walter C; Anaizi, Amjad

    2017-06-09

    The pineal gland has a deep central location, making it a surgeon's no man's land. Surgical pathology within this territory presents a unique challenge and an opportunity for employment of various surgical techniques. In modern times, the microsurgical technique has been competing with the endoscope for achieving superior surgical results. We describe two cases utilizing a purely endoscopic and an endoscopic-assisted supracerebellar infratentorial approach in accessing lesions of the pineal gland. We also discuss our early learning experience with these approaches.

  15. Supracerebellar Infratentorial Endoscopic and Endoscopic-Assisted Approaches to Pineal Lesions: Technical Report and Review of the Literature

    PubMed Central

    Felbaum, Daniel R; Jean, Walter C; Anaizi, Amjad

    2017-01-01

    The pineal gland has a deep central location, making it a surgeon’s no man’s land. Surgical pathology within this territory presents a unique challenge and an opportunity for employment of various surgical techniques. In modern times, the microsurgical technique has been competing with the endoscope for achieving superior surgical results. We describe two cases utilizing a purely endoscopic and an endoscopic-assisted supracerebellar infratentorial approach in accessing lesions of the pineal gland. We also discuss our early learning experience with these approaches. PMID:28690962

  16. Endoscopic Devices for Obesity.

    PubMed

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.

  17. Endoscopic Skull Base Surgery

    PubMed Central

    Senior, Brent A

    2008-01-01

    Endoscopic skull base surgery has undergone rapid advancement in the past decade moving from pituitary surgery to suprasellar lesions and now to a myriad of lesions extending from the cribriform plate to C2 and laterally out to the infratemporal fossa and petrous apex. Evolution of several technological advances as well as advances in understanding of endoscopic anatomy and the development of surgical techniques both in resection and reconstruction have fostered this capability. Management of benign disease via endoscopic methods is largely accepted now but more data is needed before the controversy on the role of endoscopic management of malignant disease is decided. Continued advances in surgical technique, navigation systems, endoscopic imaging technology, and robotics assure continued brisk evolution in this expanding field. PMID:19434274

  18. Endoscopic resection of subepithelial tumors.

    PubMed

    Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; Caca, Karel

    2014-12-16

    Management of subepithelial tumors (SETs) remains challenging. Endoscopic ultrasound (EUS) has improved differential diagnosis of these tumors but a definitive diagnosis on EUS findings alone can be achieved in the minority of cases. Complete endoscopic resection may provide a reasonable approach for tissue acquisition and may also be therapeutic in case of malignant lesions. Small SET restricted to the submucosa can be removed with established basic resection techniques. However, resection of SET arising from deeper layers of the gastrointestinal wall requires advanced endoscopic methods and harbours the risk of perforation. Innovative techniques such as submucosal tunneling and full thickness resection have expanded the frontiers of endoscopic therapy in the past years. This review will give an overview about endoscopic resection techniques of SET with a focus on novel methods.

  19. Clinical relevance of endoscopic assessment of inflammation in ulcerative colitis: Can endoscopic evaluation predict outcomes?

    PubMed Central

    Mohammed, Noor; Subramanian, Venkataraman

    2016-01-01

    Ulcerative colitis (UC) is a chronic inflammatory bowel condition characterised by a relapsing and remitting course. Symptom control has been the traditional mainstay of medical treatment. It is well known that histological inflammatory activity persists despite adequate symptom control and absence of endoscopic inflammation. Current evidence suggests that presence of histological inflammation poses a greater risk of disease relapse and subsequent colorectal cancer risk. New endoscopic technologies hold promise for developing endoscopic markers of mucosal inflammation. Achieving endoscopic and histological remission appears be the future aim of medical treatments for UC. This review article aims to evaluate the use of endoscopy as a tool in assessment of mucosal inflammation UC and its correlation with disease outcomes. PMID:27895420

  20. Endoscopic ultrasound

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/007646.htm Endoscopic ultrasound To use the sharing features on this page, please enable JavaScript. Endoscopic ultrasound is a type of imaging test. It is ...

  1. Characterization of Complications Associated with Open and Endoscopic Craniosynostosis Surgery at a Single Institution

    PubMed Central

    Han, Rowland H.; Nguyen, Dennis C.; Bruck, Brent S.; Skolnick, Gary B.; Yarbrough, Chester K.; Naidoo, Sybill D.; Patel, Kamlesh B.; Kane, Alex A.; Woo, Albert S.; Smyth, Matthew D.

    2016-01-01

    Object We present a retrospective cohort study examining complications in patients undergoing surgery for craniosynostosis using both minimally invasive endoscopic and open approaches. Methods Over the past ten years, 295 non-syndromic patients (140 endoscopic, 155 open) and 33 syndromic patients (10 endoscopic, 23 open) met our criteria. Variables analyzed included: age at surgery, presence of pre-existing CSF shunt, skin incision method, estimated blood loss (EBL), transfusions of packed red blood cells (PRBC), use of intravenous (IV) steroids or tranexamic acid (TXA), intraoperative durotomies, procedure length, and length of hospital stay. Complications were classified as either surgically or medically related. Results In the non-syndromic endoscopic group, we experienced 3 (2.1%) surgical and 5 (3.6%) medical complications. In the non-syndromic open group, there were 2 (1.3%) surgical and 7 (4.5%) medical complications. Intraoperative durotomies occurred in 5 (3.6%) endoscopic and 12 (7.8%) open cases, were repaired primarily, and did not result in reoperations for CSF leakage. Syndromic cases resulted in similar complication rates. No mortality or permanent morbidity occurred. Additionally, endoscopic procedures were associated with significantly decreased EBL, transfusions, procedure lengths, and lengths of hospital stay compared to open procedures. Conclusions Rates of intraoperative durotomies, surgical and medical complications were comparable between endoscopic and open techniques. This is the largest direct comparison to date between endoscopic and open interventions for synostosis, and the results are in agreement with previous series that endoscopic surgery confers distinct advantages over open in appropriate patient populations. PMID:26588461

  2. Is endoscopic nodular gastritis associated with premalignant lesions?

    PubMed

    Niknam, R; Manafi, A; Maghbool, M; Kouhpayeh, A; Mahmoudi, L

    2015-06-01

    Nodularity on the gastric mucosa is occasionally seen in general practice. There is no consensus about the association of nodular gastritis and histological premalignant lesions. This study is designed to investigate the prevalence of histological premalignant lesions in dyspeptic patients with endoscopic nodular gastritis. Consecutive patients with endoscopic nodular gastritis were compared with an age- and sex-matched control group. Endoscopic nodular gastritis was defined as a miliary nodular appearance of the gastric mucosa on endoscopy. Biopsy samples of stomach tissue were examined for the presence of atrophic gastritis, intestinal metaplasia, and dysplasia. The presence of Helicobacter pylori infection was determined by histology. From 5366 evaluated patients, a total of 273 patients with endoscopic nodular gastritis and 1103 participants as control group were enrolled. H. pylori infection was detected in 87.5% of the patients with endoscopic nodular gastritis, whereas 73.8% of the control group were positive for H. pylori (p < 0.001). Prevalence of incomplete intestinal metaplasia (p = 0.016) and dysplasia (p < 0.001) in patients with endoscopic nodular gastritis were significantly higher than in the control group. Prevalence of atrophic gastritis and complete intestinal metaplasia were also more frequent in patients with endoscopic nodular gastritis than in the control group. Dysplasia, incomplete intestinal metaplasia and H. pylori infection are significantly more frequent in patients with endoscopic nodular gastritis. Although further studies are needed before a clear conclusion can be reached, we suggest that endoscopic nodular gastritis might serve as a premalignant lesion and could be biopsied in all patients for the possibility of histological premalignancy, in addition to H. pylori infection.

  3. Posterior Percutaneous Endoscopic Cervical Foraminotomy and Diskectomy With Unilateral Biportal Endoscopy.

    PubMed

    Park, Jae Hyun; Jun, Su Gi; Jung, Je Tae; Lee, Sang Jin

    2017-09-01

    This report describes a new, minimally invasive procedure, posterior percutaneous endoscopic cervical diskectomy, performed with a unilateral biportal endoscopic approach. The procedure is used to treat cervical foraminal soft disk protrusion. This report also describes the short-term results with this procedure. In 2015, 14 patients underwent this new, minimally invasive procedure. The technique was applied with a standard arthroscopy device and conventional spine instruments. The Neck Disability Index and visual analog scale scores for the neck and upper arm were evaluated, and 13 consecutive patients were included in the analysis. Mean follow-up was 14.8 months (range, 12-18 months). The Neck Disability Index decreased from 27.0±2.5 to 6.8±1.4 at the last follow-up (P<.05). Visual analog scale scores for the neck and upper arm also decreased significantly (neck, 6.2±0.8 to 2.4±0.9; upper arm, 7.0±1.1 to 2.2±0.6). Posterior percutaneous endoscopic cervical diskectomy with a uniportal endoscope provides a clear operative field because of continuous endoscopic saline irrigation and requires only a short hospitalization and no postoperative rehabilitation. Posterior percutaneous endoscopic cervical diskectomy with a unilateral biportal endoscopic approach also can be performed efficiently because of the wide field of visualization and familiar surgical field. Thus, posterior percutaneous endoscopic cervical diskectomy with the unilateral biportal endoscopic approach may be an alternative procedure for cervical foraminal soft disk protrusion. [Orthopedics. 2017; 40(5):e779-e783.]. Copyright 2017, SLACK Incorporated.

  4. Thermal effects of endoscopy in a human temporal bone model: Implications for endoscopic ear surgery

    PubMed Central

    Kozin, Elliott D.; Lehmann, Ashton; Carter, Margaret; Hight, Ed; Cohen, Michael; Nakajima, Hideko Heidi; Lee, Daniel J.

    2015-01-01

    Objective Although the theoretical risk of elevated temperatures during endoscopic ear surgery has been reported previously, neither temperature change nor heat distribution associated with the endoscope has been quantified. In this study, we measure temperature changes during rigid middle ear endoscopy in a human temporal bone model and investigate whether suction can act as a significant cooling mechanism. Study Design Human temporal bone model of endoscopic middle ear surgery. Methods Fresh human temporal bones were maintained at body temperature (~36°C). Temperature fluctuations were measured as a function of 1) distance between the tip of a 3mm 0° Hopkins rod and round window membrane, and 2) intensity of the light source. Infrared imaging determined the thermal gradient. For suction, a #20 French was utilized. Results We found: 1) an endoscope maximally powered by a xenon or LED light source resulted in a rapid temperature elevation up to 46°C within 0.5–1mm from the tip of the endoscope within 30–124 seconds; 2) elevated temperatures occurred up to 8mm from the endoscope tip; and 3) temperature decreased rapidly within 20–88 seconds of turning off the light source or applying suction. Conclusion Our findings have direct implications for avoiding excessive temperature elevation in endoscopic ear surgery. We recommend: 1) using submaximal light intensity, 2) frequent repositioning of the endoscope, and 3) removing the endoscope to allow tissue cooling. Use of suction provides rapid cooling of the middle ear space and may be incorporated in the design of new instrumentation for prolonged dissection. PMID:24604692

  5. Surveillance of Endoscopes: Comparison of Different Sampling Techniques.

    PubMed

    Cattoir, Lien; Vanzieleghem, Thomas; Florin, Lisa; Helleputte, Tania; De Vos, Martine; Verhasselt, Bruno; Boelens, Jerina; Leroux-Roels, Isabel

    2017-09-01

    OBJECTIVE To compare different techniques of endoscope sampling to assess residual bacterial contamination. DESIGN Diagnostic study. SETTING The endoscopy unit of an 1,100-bed university hospital performing ~13,000 endoscopic procedures annually. METHODS In total, 4 sampling techniques, combining flushing fluid with or without a commercial endoscope brush, were compared in an endoscope model. Based on these results, sterile physiological saline flushing with or without PULL THRU brush was selected for evaluation on 40 flexible endoscopes by adenosine triphosphate (ATP) measurement and bacterial culture. Acceptance criteria from the French National guideline (<25 colony-forming units [CFU] per endoscope and absence of indicator microorganisms) were used as part of the evaluation. RESULTS On biofilm-coated PTFE tubes, physiological saline in combination with a PULL THRU brush generated higher mean ATP values (2,579 relative light units [RLU]) compared with saline alone (1,436 RLU; P=.047). In the endoscope samples, culture yield using saline plus the PULL THRU (mean, 43 CFU; range, 1-400 CFU) was significantly higher than that of saline alone (mean, 17 CFU; range, 0-500 CFU; P<.001). In samples obtained using the saline+PULL THRU brush method, ATP values of samples classified as unacceptable were significantly higher than those of samples classified as acceptable (P=.001). CONCLUSION Physiological saline flushing combined with PULL THRU brush to sample endoscopes generated higher ATP values and increased the yield of microbial surveillance culture. Consequently, the acceptance rate of endoscopes based on a defined CFU limit was significantly lower when the saline+PULL THRU method was used instead of saline alone. Infect Control Hosp Epidemiol 2017;38:1062-1069.

  6. Endoscopic vs. microscopic transsphenoidal surgery for Cushing's disease: a systematic review and meta-analysis.

    PubMed

    Broersen, Leonie H A; Biermasz, Nienke R; van Furth, Wouter R; de Vries, Friso; Verstegen, Marco J T; Dekkers, Olaf M; Pereira, Alberto M

    2018-05-16

    Systematic review and meta-analysis comparing endoscopic and microscopic transsphenoidal surgery for Cushing's disease regarding surgical outcomes (remission, recurrence, and mortality) and complication rates. To stratify the results by tumor size. Nine electronic databases were searched in February 2017 to identify potentially relevant articles. Cohort studies assessing surgical outcomes or complication rates after endoscopic or microscopic transsphenoidal surgery for Cushing's disease were eligible. Pooled proportions were reported including 95% confidence intervals. We included 97 articles with 6695 patients in total (5711 microscopically and 984 endoscopically operated). Overall, remission was achieved in 5177 patients (80%), with no clear difference between both techniques. Recurrence was around 10% and short term mortality < 0.5% for both techniques. Cerebrospinal fluid leak occurred more often in endoscopic surgery (12.9 vs. 4.0%), whereas transient diabetes insipidus occurred less often (11.3 vs. 21.7%). For microadenomas, results were comparable between both techniques. For macroadenomas, the percentage of patients in remission was higher after endoscopic surgery (76.3 vs. 59.9%), and the percentage recurrence lower after endoscopic surgery (1.5 vs. 17.0%). Endoscopic surgery for patients with Cushing's disease reaches comparable results for microadenomas, and probably better results for macroadenomas than microscopic surgery. This is present despite the presumed learning curve of the newer endoscopic technique, although confounding cannot be excluded. Based on this study, endoscopic surgery may thus be considered the current standard of care. Microscopic surgery can be used based on neurosurgeon's preference. Endocrinologists and neurosurgeons in pituitary centers performing the microscopic technique should at least consider referring Cushing's disease patients with a macroadenoma.

  7. Shape memory alloy-based biopsy device for active locomotive intestinal capsule endoscope.

    PubMed

    Le, Viet Ha; Hernando, Leon-Rodriguez; Lee, Cheong; Choi, Hyunchul; Jin, Zhen; Nguyen, Kim Tien; Go, Gwangjun; Ko, Seong-Young; Park, Jong-Oh; Park, Sukho

    2015-03-01

    Recently, capsule endoscopes have been used for diagnosis in digestive organs. However, because a capsule endoscope does not have a locomotive function, its use has been limited to small tubular digestive organs, such as small intestine and esophagus. To address this problem, researchers have begun studying an active locomotive intestine capsule endoscope as a medical instrument for the whole gastrointestinal tract. We have developed a capsule endoscope with a small permanent magnet that is actuated by an electromagnetic actuation system, allowing active and flexible movement in the patient's gut environment. In addition, researchers have noted the need for a biopsy function in capsule endoscope for the definitive diagnosis of digestive diseases. Therefore, this paper proposes a novel robotic biopsy device for active locomotive intestine capsule endoscope. The proposed biopsy device has a sharp blade connected with a shape memory alloy actuator. The biopsy device measuring 12 mm in diameter and 3 mm in length was integrated into our capsule endoscope prototype, where the device's sharp blade was activated and exposed by the shape memory alloy actuator. Then the electromagnetic actuation system generated a specific motion of the capsule endoscope to extract the tissue sample from the intestines. The final biopsy sample tissue had a volume of about 6 mm(3), which is a sufficient amount for a histological analysis. Consequently, we proposed the working principle of the biopsy device and conducted an in-vitro biopsy test to verify the feasibility of the biopsy device integrated into the capsule endoscope prototype using the electro-magnetic actuation system. © IMechE 2015.

  8. Novel and safer endoscopic cholecystectomy using only a flexible endoscope via single port

    PubMed Central

    Mori, Hirohito; Kobayashi, Nobuya; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Chiyo, Taiga; Ayaki, Maki; Nagase, Takashi; Masaki, Tsutomu

    2016-01-01

    AIM: To apply the laparoscopic and endoscopic cooperative surgery concept, we investigated whether endoscopic cholecystectomy could be performed more safely and rapidly via only 1 port or not. METHODS: Two dogs (11 and 13-mo-old female Beagle) were used in this study. Only 1 blunt port was created, and a flexible endoscope with a tip attachment was inserted between the fundus of gallbladder and liver. After local injection of saline to the gallbladder bed, resection of the gallbladder bed from the liver was performed. After complete resection of the gallbladder bed, the gallbladder was pulled up to resect its neck using the Ring-shaped thread technique. The neck of the gallbladder was cut using scissor forceps. Resected gallbladder was retrieved using endoscopic net forceps via a port. RESULTS: The operation times from general anesthetizing with sevoflurane to finishing the closure of the blunt port site were about 50 min and 60 min respectively. The resection times of gallbladder bed were about 15 min and 13 min respectively without liver injury and bleeding at all. Feed were given just after next day of operation, and they had a good appetite. Two dogs are in good health now and no complications for 1 mo after endoscopic cholecystectomy using only a flexible endoscope via one port. CONCLUSION: We are sure of great feasibility of endoscopic cholecystectomy via single port for human. PMID:27053847

  9. [Endoscopic extraction of gallbladder calculi].

    PubMed

    Kühner, W; Frimberger, E; Ottenjann, R

    1984-06-29

    Endoscopic extraction of gallbladder stones were performed, as far as we know for the first time, in three patients with combined choledochocystolithiasis. Following endoscopic papillotomy (EPT) and subsequent mechanical lithotripsy of multiple choledochal concrements measuring up to 3 cm the gallbladder stones were successfully extracted with a Dormia basket through the cystic duct. The patients have remained free of complications after the endoscopic intervention.

  10. Endoscopic Gallbladder Drainage for Acute Cholecystitis

    PubMed Central

    Widmer, Jessica; Alvarez, Paloma; Sharaiha, Reem Z.; Gossain, Sonia; Kedia, Prashant; Sarkaria, Savreet; Sethi, Amrita; Turner, Brian G.; Millman, Jennifer; Lieberman, Michael; Nandakumar, Govind; Umrania, Hiren; Gaidhane, Monica

    2015-01-01

    Background/Aims Surgery is the mainstay of treatment for cholecystitis. However, gallbladder stenting (GBS) has shown promise in debilitated or high-risk patients. Endoscopic transpapillary GBS and endoscopic ultrasound-guided GBS (EUS-GBS) have been proposed as safe and effective modalities for gallbladder drainage. Methods Data from patients with cholecystitis were prospectively collected from August 2004 to May 2013 from two United States academic university hospitals and analyzed retrospectively. The following treatment algorithm was adopted. Endoscopic retrograde cholangiopancreatography (ERCP) with sphincterotomy and cystic duct stenting was initially attempted. If deemed feasible by the endoscopist, EUS-GBS was then pursued. Results During the study period, 139 patients underwent endoscopic gallbladder drainage. Among these, drainage was performed in 94 and 45 cases for benign and malignant indications, respectively. Successful endoscopic gallbladder drainage was defined as decompression of the gallbladder without incidence of cholecystitis, and was achieved with ERCP and cystic duct stenting in 117 of 128 cases (91%). Successful endoscopic gallbladder drainage was also achieved with EUS-guided gallbladder drainage using transmural stent placement in 11 of 11 cases (100%). Complications occurred in 11 cases (8%). Conclusions Endoscopic gallbladder drainage techniques are safe and efficacious methods for gallbladder decompression in non-surgical patients with comorbidities. PMID:26473125

  11. A Haptic Guided Robotic System for Endoscope Positioning and Holding.

    PubMed

    Cabuk, Burak; Ceylan, Savas; Anik, Ihsan; Tugasaygi, Mehtap; Kizir, Selcuk

    2015-01-01

    To determine the feasibility, advantages, and disadvantages of using a robot for holding and maneuvering the endoscope in transnasal transsphenoidal surgery. The system used in this study was a Stewart Platform based robotic system that was developed by Kocaeli University Department of Mechatronics Engineering for positioning and holding of endoscope. After the first use on an artificial head model, the system was used on six fresh postmortem bodies that were provided by the Morgue Specialization Department of the Forensic Medicine Institute (Istanbul, Turkey). The setup required for robotic system was easy, the time for registration procedure and setup of the robot takes 15 minutes. The resistance was felt on haptic arm in case of contact or friction with adjacent tissues. The adaptation process was shorter with the mouse to manipulate the endoscope. The endoscopic transsphenoidal approach was achieved with the robotic system. The endoscope was guided to the sphenoid ostium with the help of the robotic arm. This robotic system can be used in endoscopic transsphenoidal surgery as an endoscope positioner and holder. The robot is able to change the position easily with the help of an assistant and prevents tremor, and provides a better field of vision for work.

  12. Review of Pure Endoscopic Full-Thickness Resection of the Upper Gastrointestinal Tract

    PubMed Central

    Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Masaki, Tsutomu

    2015-01-01

    Natural-orifice transluminal endoscopic surgery (NOTES) using flexible endoscopy has attracted attention as a minimally invasive surgical method that does not cause an operative wound on the body surface. However, minimizing the number of devices involved in endoscopic, compared to laparoscopic, surgeries has remained a challenge, causing endoscopic surgeries to gradually be phased out of use. If a flexible endoscopic full-thickness suturing device and a counter-traction device were developed to expand the surgical field for gastrointestinal-tract collapse, then endoscopic full-thickness resection using NOTES, which is seen as an extension of endoscopic submucosal dissection for full-thickness excision of tumors involving the gastrointestinal-tract wall, might become an extremely minimally invasive surgical method that could be used to resect only full-thickness lesions approached by the shortest distance via the mouth. It is expected that gastroenterological endoscopists will use this surgery if device development is advanced. This extremely minimally invasive surgery would have an immeasurable impact with regard to mitigating the burden on patients and reducing healthcare costs. Development of a new surgical method using a multipurpose flexible endoscope is therefore considered a socially urgent issue. PMID:26343069

  13. Endoscopy Assisted Oncoplastic Breast Surgery (EAOBS)

    PubMed Central

    Soybir, Gürsel; Fukuma, Eisuke

    2015-01-01

    Endoscopic oncoplastic breast surgery represents a minimal invasive approach with the aim of both removing cancer safely and also restoring the breast image. It has less noticeable scar, excellent cosmetic outcomes, high patient satisfaction rate and recently reported relatively long term safety. Operative techniques for both endoscopic breast conserving surgery and endoscopic nipple/areola/skin sparing mastectomy have been described in detail. Two different working planes in which one of them is subcutaneous and the other one is sub-mammary planes are being used during the surgery. Surgical techniqe needs some instruments such as endoscopic retractor, light guided specific mammary retractor, wound protector and bipolar scissor. Endoscopic breast retractors provide magnified visualization and extensive posterior dissection facility. Tunneling method and hydrodissection simplify the technique in the subcutaneous field. Oncoplastic reconstruction techniques are also applied after the tumor resection by endoscopic method. Complication rates of endoscopic breast surgery are similar to open breast surgery rates. Quite succesful local recurrence, distant metastasis and overall survival rates have been declared. However it looks reasonable to wait for the results with longer follow-up before having a judgement about oncologic efficiency and safety of the endoscopic breast cancer surgery. PMID:28331692

  14. Development of Tasks and Evaluation of a Prototype Forceps for NOTES

    PubMed Central

    Addis, Matthew; Aguirre, Milton; Haluck, Randy; Matthew, Abraham; Pauli, Eric; Gopal, Jegan

    2012-01-01

    Background and Objectives: Few standardized testing procedures exist for instruments intended for Natural Orifice Translumenal Endoscopic Surgery. These testing procedures are critical for evaluating surgical skills and surgical instruments to ensure sufficient quality. This need is widely recognized by endoscopic surgeons as a major hurdle for the advancement of Natural Orifice Translumenal Endoscopic Surgery. Methods: Beginning with tasks currently used to evaluate laparoscopic surgeons and instruments, new tasks were designed to evaluate endoscopic surgical forceps instruments. Results: Six tasks have been developed from existing tasks, adapted and modified for use with endoscopic instruments, or newly designed to test additional features of endoscopic forceps. The new tasks include the Fuzzy Ball Task, Cup Drop Task, Ring Around Task, Material Pull Task, Simulated Biopsy Task, and the Force Gauge Task. These tasks were then used to evaluate the performance of a new forceps instrument designed at Pennsylvania State University. Conclusions: The need for testing procedures for the advancement of Natural Orifice Translumenal Endoscopic Surgery has been addressed in this work. The developed tasks form a basis for not only testing new forceps instruments, but also for evaluating individual performance of surgical candidates with endoscopic forceps instruments. PMID:22906337

  15. Endoscopic submucosal dissection for locally recurrent colorectal lesions after previous endoscopic mucosal resection.

    PubMed

    Zhou, Pinghong; Yao, Liqing; Qin, Xinyu; Xu, Meidong; Zhong, Yunshi; Chen, Weifeng

    2009-02-01

    The objective of this study was to determine the efficacy and safety of endoscopic submucosal dissection for locally recurrent colorectal cancer after previous endoscopic mucosal resection. A total of 16 patients with locally recurrent colorectal lesions were enrolled. A needle knife, an insulated-tip knife and a hook knife were used to resect the lesion along the submucosa. The rate of the curative resection, procedure time, and incidence of complications were evaluated. Of 16 lesions, 15 were completely resected with endoscopic submucosal dissection, yielding an en bloc resection rate of 93.8 percent. Histologic examination confirmed that lateral and basal margins were cancer-free in 14 patients (87.5 percent). The average procedure time was 87.2 +/- 60.7 minutes. None of the patients had immediate or delayed bleeding during or after endoscopic submucosal dissection. Perforation in one patient (6.3 percent) was the only complication and was managed conservatively. The mean follow-up period was 15.5 +/- 6.8 months; none of the patients experienced lesion residue or recurrence. Endoscopic submucosal dissection appears to be effective for locally recurrent colorectal cancer after previous endoscopic mucosal resection, making it possible to resect whole lesions and provide precise histologic information.

  16. The Correlation of Endoscopic Findings and Clinical Features in Korean Patients with Scrub Typhus: A Cohort Study

    PubMed Central

    Lee, Jun; Kim, Dong-Min; Yun, Na Ra; Kim, Young Dae; Park, Chan Guk; Kim, Man Woo

    2016-01-01

    Scrub typhus is an infectious disease caused by Orientia tsutsugamushi-induced systemic vasculitis, but the involvement of the gastrointestinal tract and the endoscopic findings associated with scrub typhus are not well understood. We performed a prospective study and recommend performing esophagogastroduodenoscopy (EGD) for all possible scrub typhus patients, regardless of gastrointestinal symptoms. Gastrointestinal symptoms, endoscopic findings and clinical severity based on organ involvement and ICU admission were analyzed. Gastrointestinal symptoms occurred in up to 76.4% of scrub typhus patients. The major endoscopic findings were ulcers (43/127, 33.9%). Interestingly, 7.1% (9/127) of the patients presented with esophageal candidiasis. There was no correlation between the presence or absence of gastrointestinal symptoms and the endoscopic grade (P = 0.995). However, there was a positive correlation between the clinical severity and the endoscopic findings (P = 0.001). Sixty-three percent of the patients presented with erosion or ulcers on prospectively performed endoscopic evaluations, irrespective of gastrointestinal symptoms. Gastrointestinal symptoms did not reflect the need for endoscopy. Scrub typhus patients could have significant endoscopic abnormalities even in the absence of gastrointestinal symptoms. PMID:27195943

  17. Innovative surgical endoscopes in video-assisted thoracic surgery

    PubMed Central

    Cheng, Truman; Ng, Calvin S. H.

    2018-01-01

    In the past three decades, rod lens endoscopes had facilitated the development and wide spread applications of video-assisted thoracic surgery (VATS). With the rise of uniportal VATS in recent years, innovations in surgical instruments should once again complement the advancement in surgical technique. While articulated flexible endoscopes have expand the field of view, and can alter viewing direction with minimal maneuvers, they still suffer from problems like trocar crowding and interference with other instruments. Magnetic anchored endoscopes, on the other hand, may provide unique benefits to VATS by replacing the endoscope rigid rod body with magnetic linkage, thus overcoming the challenge of port crowding in single incision surgery. Most magnetic anchored endoscopes reported in literature are not designed for thoracic surgeries. Many of these designs do not allow tilting of endoscopic view, rely on micromotors for actuation, or are ergonomically unfit to be operated within the spatial constraints seen in VATS application. Considering these limitations, we have designed two novel magnetic anchored and steered endoscopes targeted for uniportal VATS. Both designs could be wirelessly actuated by magnetic interaction. One has a silicone rubber formed soft body for compactness, lightweight and safety, while another is a 40 mm long capsule optimized for VATS spatial constraints. PMID:29732196

  18. Innovative surgical endoscopes in video-assisted thoracic surgery.

    PubMed

    Cheng, Truman; Ng, Calvin S H; Li, Zheng

    2018-04-01

    In the past three decades, rod lens endoscopes had facilitated the development and wide spread applications of video-assisted thoracic surgery (VATS). With the rise of uniportal VATS in recent years, innovations in surgical instruments should once again complement the advancement in surgical technique. While articulated flexible endoscopes have expand the field of view, and can alter viewing direction with minimal maneuvers, they still suffer from problems like trocar crowding and interference with other instruments. Magnetic anchored endoscopes, on the other hand, may provide unique benefits to VATS by replacing the endoscope rigid rod body with magnetic linkage, thus overcoming the challenge of port crowding in single incision surgery. Most magnetic anchored endoscopes reported in literature are not designed for thoracic surgeries. Many of these designs do not allow tilting of endoscopic view, rely on micromotors for actuation, or are ergonomically unfit to be operated within the spatial constraints seen in VATS application. Considering these limitations, we have designed two novel magnetic anchored and steered endoscopes targeted for uniportal VATS. Both designs could be wirelessly actuated by magnetic interaction. One has a silicone rubber formed soft body for compactness, lightweight and safety, while another is a 40 mm long capsule optimized for VATS spatial constraints.

  19. Current Status of Peroral Endoscopic Myotomy

    PubMed Central

    Cho, Young Kwan; Kim, Seong Hwan

    2018-01-01

    Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders. PMID:29397656

  20. Current Status of Peroral Endoscopic Myotomy.

    PubMed

    Cho, Young Kwan; Kim, Seong Hwan

    2018-01-01

    Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders.

  1. Laparoscopic-endoscopic cooperative surgery is a safe and effective treatment for superficial nonampullary duodenal tumors.

    PubMed

    Kyuno, Daisuke; Ohno, Keisuke; Katsuki, Shinichi; Fujita, Tomoki; Konno, Ai; Murakami, Takeshi; Waga, Eriko; Takanashi, Kunihiro; Kitaoka, Keisuke; Komatsu, Yuya; Sasaki, Kazuaki; Hirata, Koichi

    2015-11-01

    The use of endoscopic submucosal dissection (ESD) for duodenal neoplasms has increased in recent years, but delayed perforation and bleeding are also known to frequently occur. We present two cases in which duodenal adenoma was successfully treated with laparoscopic-endoscopic cooperative surgery. ESD was combined with laparoscopic seromuscular sutures. The lesions in both cases were located in the second portion of the duodenum. The patients requested resection of the lesion, and we performed laparoscopic-endoscopic cooperative surgery. After the laparoscopic surgeon mobilized the duodenum, the endoscopic surgeon performed ESD for the duodenal tumor without perforation. The laparoscopic surgeon sutured the duodenal wall in the seromuscular layer to strengthen the ulcer bed after ESD. Histopathological studies confirmed that the surgical margins were tumor-free in both cases. The patients were discharged with no complications. This unique laparoscopic-endoscopic cooperative procedure is a safe and effective method for resecting superficial nonampullary duodenal tumors. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  2. Design and application of a new series of gallbladder endoscopes that facilitate gallstone removal without gallbladder excision

    NASA Astrophysics Data System (ADS)

    Qiao, Tie; Huang, Wan-Chao; Luo, Xiao-Bing; Zhang, Yang-De

    2012-01-01

    In recent years, some Chinese doctors have proposed a new concept, gallstone removal without gallbladder excision, along with transition of the medical model. As there is no specialized endoscope for gallstone removal without gallbladder excision, we designed and produced a new series of gallbladder endoscopes and accessories that have already been given a Chinese invention patent (No. ZL200810199041.2). The design of these gallbladder endoscopes was based on the anatomy and physiology of the gallbladder, characteristics of gallbladder disease, ergonomics, and industrial design. This series of gallbladder endoscopes underwent clinical trials in two hospitals appointed by the State Administration of Traditional Chinese Medicine. The clinical trials showed that surgeries of gallstones, gallbladder polyps, and cystic duct calculus could be smoothly performed with these products. In summary, this series of gallbladder endoscopes is safe, reliable, and effective for gallstone removal without gallbladder excision. This note comprehensively introduces the research and design of this series of gallbladder endoscopes.

  3. Endoscopic surgical management of sinonasal inverted papilloma extending to frontal sinuses.

    PubMed

    Takahashi, Yukiko; Shoji, Fumi; Katori, Yukio; Hidaka, Hiroshi; Noguchi, Naoya; Abe, Yasuhiro; Kakuta, Risako Kakuta; Suzuki, Takahiro; Suzuki, Yusuke; Ohta, Nobuo; Kakehata, Seiji; Okamoto, Yoshitaka

    2016-11-10

    Sinonasal inverted papilloma has been traditionally managed with external surgical approaches. Advances in imaging guidance systems, surgical instrumentation, and intraoperative multi-visualization have led to a gradual shift from external approaches to endoscopic surgery. However, for anatomical and technical reasons, endoscopic surgery of sinonasal inverted papilloma extending to the frontal sinuses is still challenging. Here, we present our experience in endoscopic surgical management of sinonasal inverted papilloma extending to one or both frontal sinuses. We present 10 cases of sinonasal inverted papilloma extending to the frontal sinuses and successfully removed by endoscopic median drainage (Draf III procedure) under endoscopic guidance without any additional external approach. The whole cavity of the frontal sinuses was easily inspected at the end of the surgical procedure. No early or late complications were observed. No recurrence was identified after an average follow-up period of 39.5 months. Use of an endoscopic median drainage approach to manage sinonasal inverted papilloma extending to one or both frontal sinuses is feasible and seems effective.

  4. Design of a handheld optical coherence microscopy endoscope

    NASA Astrophysics Data System (ADS)

    Korde, Vrushali R.; Liebmann, Erica; Barton, Jennifer K.

    2011-06-01

    Optical coherence microscopy (OCM) combines coherence gating, high numerical aperture optics, and a fiber-core pinhole to provide high axial and lateral resolution with relatively large depth of imaging. We present a handheld rigid OCM endoscope designed for small animal surgical imaging, with a 6-mm diam tip, 1-mm scan width, and 1-mm imaging depth. X-Y scanning is performed distally with mirrors mounted to micro galvonometer scanners incorporated into the endoscope handle. The endoscope optical design consists of scanning doublets, an afocal Hopkins relay lens system, a 0.4 numerical aperture water immersion objective, and a cover glass. This endoscope can resolve laterally a 1.4-μm line pair feature and has an axial resolution (full width half maximum) of 5.4 μm. Images taken with this endoscope of fresh ex-vivo mouse ovaries show structural features, such as corpus luteum, primary follicles, growing follicles, and fallopian tubes. This rigid handheld OCM endoscope can be useful for a variety of minimally invasive and surgical imaging applications.

  5. Emergency treatment of esophageal varix incarceration in the endoscope and ligation device during endoscopic variceal rubber band ligation

    PubMed Central

    Zhao, Hong; Cheng, Jilin; Xu, Yahong; Lu, Cuili; Huang, Shaoping; Fan, Zhenyu; Shi, Yuxin

    2014-01-01

    Sclerotherapy and endoscopic esophageal variceal ligation (EVL) are commonly used to treat and prevent variceal bleeding. As of today, there has been no report on an unexpected incarceration of a varix hooked on with the bands from the endoscopic EVL device. We recently experienced this emergency while using the 7-band ring endoscopic EVL device (Boston Scientific Corp., Boston, MA) for prophylaxis of variceal bleeding. In this case, the varix body itself was accidently incarcerated in the crevice of the esophageal endoscope after highly negative pressure of absorption was applied on the endoscope. In this situation, using force to take out the gastroscope was not an option as it would tear the vein and cause massive hemorrhage. We were managed to ligate the varix with rubber bands while releasing the incarceration. We observed that ligation of the varix at the same position using all seven ligation bands resulted in disappearance of the targeted varix. The surrounding esophageal mucosa became smooth after the treatment. PMID:25550983

  6. Flexible endoscopes: structure and function. The suction and biopsy channel.

    PubMed

    Holland, P

    2001-01-01

    Flexible endoscopes are complex medical instruments that are easily damaged. To maintain the flexible endoscope in optimum working condition, the user must have a thorough understanding of the structure and function of the instrument. This is the second in a series of articles presenting an in-depth look at the care and handling of the flexible endoscope. The first article discussed the air and water system. This article will focus specifically on the suction and biopsy channel system. The flexible endoscope is constructed of several systems that operate simultaneously to produce a highly technical, yet effective diagnostic and therapeutic medical device. These systems include the air and water system, the suction or operating channel system, the mechanical system, the endoscopic retrograde cholangiopancreatography (ERCP) elevator system, the optical system, and the electrical system. A review of the internal and external structure of the flexible endoscope and the functions of the channel system, including infection control issues, potential problems and evaluation, and prevention of minor problems to avoid expensive repairs, will be addressed.

  7. Endoscopic injection therapy.

    PubMed

    Kim, Sang Woon; Lee, Yong Seung; Han, Sang Won

    2017-06-01

    Since the U.S. Food and Drug Administration approved dextranomer/hyaluronic acid copolymer (Deflux) for the treatment of vesicoureteral reflux, endoscopic injection therapy using Deflux has become a popular alternative to open surgery and continuous antibiotic prophylaxis. Endoscopic correction with Deflux is minimally invasive, well tolerated, and provides cure rates approaching those of open surgery (i.e., approximately 80% in several studies). However, in recent years a less stringent approach to evaluating urinary tract infections (UTIs) and concerns about long-term efficacy and complications associated with endoscopic injection have limited the use of this therapy. In addition, there is little evidence supporting the efficacy of endoscopic injection therapy in preventing UTIs and vesicoureteral reflux-related renal scarring. In this report, we reviewed the current literature regarding endoscopic injection therapy and provided an updated overview of this topic.

  8. Robust feature tracking for endoscopic pose estimation and structure recovery

    NASA Astrophysics Data System (ADS)

    Speidel, S.; Krappe, S.; Röhl, S.; Bodenstedt, S.; Müller-Stich, B.; Dillmann, R.

    2013-03-01

    Minimally invasive surgery is a highly complex medical discipline with several difficulties for the surgeon. To alleviate these difficulties, augmented reality can be used for intraoperative assistance. For visualization, the endoscope pose must be known which can be acquired with a SLAM (Simultaneous Localization and Mapping) approach using the endoscopic images. In this paper we focus on feature tracking for SLAM in minimally invasive surgery. Robust feature tracking and minimization of false correspondences is crucial for localizing the endoscope. As sensory input we use a stereo endoscope and evaluate different feature types in a developed SLAM framework. The accuracy of the endoscope pose estimation is validated with synthetic and ex vivo data. Furthermore we test the approach with in vivo image sequences from da Vinci interventions.

  9. Endoscopic resection of subepithelial tumors

    PubMed Central

    Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; Caca, Karel

    2014-01-01

    Management of subepithelial tumors (SETs) remains challenging. Endoscopic ultrasound (EUS) has improved differential diagnosis of these tumors but a definitive diagnosis on EUS findings alone can be achieved in the minority of cases. Complete endoscopic resection may provide a reasonable approach for tissue acquisition and may also be therapeutic in case of malignant lesions. Small SET restricted to the submucosa can be removed with established basic resection techniques. However, resection of SET arising from deeper layers of the gastrointestinal wall requires advanced endoscopic methods and harbours the risk of perforation. Innovative techniques such as submucosal tunneling and full thickness resection have expanded the frontiers of endoscopic therapy in the past years. This review will give an overview about endoscopic resection techniques of SET with a focus on novel methods. PMID:25512768

  10. Endoscopic electrosurgical papillotomy and manometry in biliary tract disease.

    PubMed

    Geenen, J E; Hogan, W J; Shaffer, R D; Stewart, E T; Dodds, W J; Arndorfer, R C

    1977-05-09

    Endoscopic papillotomy was performed in 13 patients after cholecystectomy for retained or recurrent common bile duct calculi (11 patients) and a clinical picture suggesting papillary stenosis (two patients). Following endoscopic papillotomy, ten of the 11 patients spontaneously passed common bile duct (CBD) stones verified on repeated endoscopic retrograde cholangiopancreatography (ERCP) study. One patient failed to pass a large CBD calculus; one patient experienced cholangitis three months after in inadequate papillotomy and required operative intervention. Endoscopic papillotomy substantially decreased the pressure gradient existing between the CBD and the duodenum in all five patients studied with ERCP manometry. Endoscopic papillotomy is a relatively safe and effective procedure for postcholecystectomy patients with retained or recurrent CBD stones. The majority of CBD stones will pass spontaneously if the papillotomy is adequate.

  11. Removal of impacted esophageal foreign bodies with a dual-channel endoscope: 19 cases

    PubMed Central

    WANG, CHANGXIONG; CHEN, PING

    2013-01-01

    There have been few reports concerning the endoscopic removal of impacted esophageal foreign bodies from patients. The objective of this study was to evaluate the effectiveness of dual-channel endoscopy in managing foreign-body ingestions in patients. A total of 19 patients with foreign-body ingestions between September 2008 and July 2011 were selected from the Digestive Endoscope Center in Lishui, a typical middle-sized city in China. The patients underwent endoscopy following admission. The impacted foreign bodies were successfully removed from 18 patients without complications using a dual-channel endoscope. One patient underwent surgery for an ingested denture following the failure of the endoscopic removal method. This study demonstrates that dual-channel endoscopic management may be a useful option for removing ingested foreign bodies from the esophagus. PMID:23935752

  12. Endoscopic management of difficult common bile duct stones

    PubMed Central

    Trikudanathan, Guru; Navaneethan, Udayakumar; Parsi, Mansour A

    2013-01-01

    Endoscopy is widely accepted as the first treatment option in the management of bile duct stones. In this review we focus on the alternative endoscopic modalities for the management of difficult common bile duct stones. Most biliary stones can be removed with an extraction balloon, extraction basket or mechanical lithotripsy after endoscopic sphincterotomy. Endoscopic papillary balloon dilation with or without endoscopic sphincterotomy or mechanical lithotripsy has been shown to be effective for management of difficult to remove bile duct stones in selected patients. Ductal clearance can be safely achieved with peroral cholangioscopy guided laser or electrohydraulic lithotripsy in most cases where other endoscopic treatment modalities have failed. Biliary stenting may be an alternative treatment option for frail and elderly patients or those with serious co morbidities. PMID:23345939

  13. Present-day potentialities of endoscopic diagnostics and treatment of early cancer in respiratory and digestive tracts

    NASA Astrophysics Data System (ADS)

    Sokolov, Victor V.; Zharkova, Natalia N.; Filonenko, E. V.; Telegina, L. V.; Karpova, E. S.

    1999-12-01

    The paper presents the latest potentialities of the endoscopic fluorescent diagnostics as well as endoscopic electric-, laser surgery and photodynamic therapy (PDT) of the early cancer in the respiratory and digestive tracts. We present in detail indication and factors determining the application of the endoscopic resection of the tumor. The advantages of the combination application of PDT, electro-, Nd:YAG laser surgery and brachitherapy are stressed. The near and remote results of endoscopic treatment of the early cancer in larynx (37), lung (109), esophagus (39) and stomach (58) are shown.

  14. Combination of endoscopic submucosal dissection and transanal minimally invasive surgery for the resection of early rectal cancer with fibrosis after prior partial excision.

    PubMed

    Kim, Sung Hoo; Yang, Dong Hoon; Lim, Seok-Byung

    2018-05-23

    Endoscopic submucosal dissection is an effective procedure for treating non-invasive colorectal tumors. However, in cases of severe fibrosis, endoscopic submucosal dissection may be technically difficult, leading to incomplete resection. Here, we describe the case of a 74-year-old man who had early rectal cancer along with severe submucosal fibrosis caused by prior local excision. Combination treatment with endoscopic submucosal dissection and transanal minimally invasive surgery successfully enabled complete resection. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  15. The proposal of the locomotive system for capsule endoscopes.

    PubMed

    Watada, Masaya; Ozawa, Ken-ichi

    2008-01-01

    The capsule endoscope authorized in some countries in late years has the advantage of preparing the observation in difficult small intestines in a past endoscope. However, because the promotion mechanism of a capsule endoscope depends only on the peristaltic motion of a digestive organ, the oversight of change to a morbid state is feared. Authors aim at the achievement of a free movement and remote diagnoses in small intestines, and are developing a locomotive system for capsule endoscopes. This paper describes the proposal of the locomotive system with an electromagnetic actuator, and examination of a simulation model for this locomotive system.

  16. Liquid disinfecting and sterilization reprocessors used for flexible endoscopes.

    PubMed

    1994-06-01

    In this issue, we evaluate three liquid disinfecting flexible endoscope reprocessors that can be used with a user-supplied liquid chemical germicide (LCG), primarily for high-level disinfection (HLD). Applying most of the same criteria and test methods, we also evaluated a fourth unit, presented separately, that is marketed as a liquid sterilizing reprocessor and must be used with manufacturer-supplied, single-use containers of LCG. Although the sterilizing unit can be used for rigid endoscopes, surgical instruments, and endoscopic accessories, we evaluated its application to the reprocessing of only flexible endoscopes. Our ratings are based on the following: (1) basic performance, such as compatibility with several different types of endoscopes and LCGs, inclusion of all essential reprocessing phases, and exposure of all endoscope surfaces to the LCG and rinse water; (2) safety, such as ensuring that essential reprocessing phases cannot be skipped or omitted, that personnel exposure to LCG vapors is minimized, and that the reprocessor is unlikely to contaminate the endoscope during reprocessing; and (3) human factors design, such as ease of use and installation. We did not perform microbiological testing to confirm HLD or sterilization by any of the evaluated reprocessors because, with a suitably clean endoscope that is in good condition, no evidence indicates that the LCGs used would not be effective on the surfaces that they contact; also, the results would be unique to the two flexible endoscopes that we used for our testing. We rated all four reprocessors Conditionally Acceptable. The units are Acceptable on the condition that users understand that they cannot be used to process the elevator cable channel of side-viewing duodenoscopes; additional conditions apply only to the liquid disinfecting units. However, if the conditions are met, all four units reduce the likelihood of using a contaminated endoscope on a patient and reduce personnel exposure to the LCG. Selection of a unit will be based on the needs and preferences of the individual healthcare facility. Our ratings also assume that these units will be used according to the manufacturers' instructions and the endoscope's operator's manual. Note that, although the evaluated liquid disinfecting units provide detergent-flushing, post-detergent water-rinse, and post-detergent water-rinse-removal phases, manual cleaning of endoscopes before automatic reprocessing is essential, regardless of which reprocessor is used.

  17. Clinical guidelines for endoscopic mucosal resection of non-pedunculated colorectal lesions.

    PubMed

    Albéniz, Eduardo; Pellisé, María; Gimeno García, Antonio Z; Lucendo, Alfredo José; Alonso Aguirre, Pedro A; Herreros de Tejada, Alberto; Álvarez, Marco Antonio; Fraile, María; Herráiz Bayod, Maite; López Rosés, Leopoldo; Martínez Ares, David; Ono, Akiko; Parra Blanco, Adolfo; Redondo, Eduardo; Sánchez Yagüe, Andrés; Soto, Santiago; Díaz Tasende, José; Montes Díaz, Marta; Téllez, Manuel Rodríguez; García, Orlando; Zuñiga Ripa, Alba; Hernández Conde, Marta; Alberca de Las Parras, Fernando; Gargallo, Carla; Saperas, Esteban; Navas, Miguel Muñoz; Gordillo, Javier; Ramos Zabala, Felipe; Echevarría, José Manuel; Bustamante, Marco; González Haba, Mariano; González Huix, Ferrán; González Suárez, Begoña; Vila Costas, Juan José; Guarner Argente, Carlos; Múgica, Fernando; Cobián, Julyssa; Rodríguez Sánchez, Joaquín; López Viedma, Bartolomé; Pin, Noel; Marín Gabriel, José Carlos; Nogales, Óscar; de la Peña, Joaquín; Navajas León, Francisco Javier; León Brito, Helena; Remedios, David; Esteban, José Miguel; Barquero, David; Martínez Cara, Juan Gabriel; Martínez Alcalá, Felipe; Fernández Urién, Ignacio; Valdivielso, Eduardo

    2018-03-01

    This document summarizes the contents of the Clinical Guidelines for the Endoscopic Mucosal Resection of Non-Pedunculated Colorectal Lesions that was developed by the working group of the Spanish Society of Digestive Endoscopy (GSEED of Endoscopic Resection). This document presents recommendations for the endoscopic management of superficial colorectal neoplastic lesions. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  18. Immediate detection of endoscopic retrograde cholangiopancreatography-related periampullary perforation: Fluoroscopy or endoscopy?

    PubMed Central

    Motomura, Yasuaki; Akahoshi, Kazuya; Gibo, Junya; Kanayama, Kenji; Fukuda, Shinichiro; Hamada, Shouhei; Otsuka, Yoshihiro; Kubokawa, Masaru; Kajiyama, Kiyoshi; Nakamura, Kazuhiko

    2014-01-01

    AIM: To investigate the causes and intraoperative detection of endoscopic retrograde cholangiopancreatography (ERCP)-related perforations to support immediate or early diagnosis. METHODS: Consecutive patients who underwent ERCP procedures at our hospital between January 2008 and June 2013 were retrospectively enrolled in the study (n = 2674). All procedures had been carried out using digital fluoroscopic assistance with the patient under conscious sedation. For patients showing alterations in the gastrointestinal anatomy, a short-type double balloon enteroscope had been applied. Cases of perforation had been identified by the presence of air in or leakage of contrast medium into the retroperitoneal space, or upon endoscopic detection of an abdominal cavity related to the perforated lumen. For patients with ERCP-related perforations, the data on medical history, endoscopic findings, radiologic findings, diagnostic methods, management, and clinical outcomes were used for descriptive analysis. RESULTS: Of the 2674 ERCP procedures performed during the 71-mo study period, only six (0.22%) resulted in perforations (male/female, 2/4; median age: 84 years; age range: 57-97 years). The cases included an endoscope-related duodenal perforation, two periampullary perforations related to endoscopic sphincterotomy, two periampullary perforations related to endoscopic papillary balloon dilation, and a periampullary or bile duct perforation secondary to endoscopic instrument trauma. No cases of guidewire-related perforation occurred. The video endoscope system employed in all procedures was only able to immediately detect the endoscope-related perforation; the other five perforation cases were all detected by subsequent digital fluoroscope applied intraoperatively (at a median post-ERCP intervention time of 15 min). Three out of the six total perforation cases, including the single case of endoscope-related duodenal injury, were surgically treated; the remaining three cases were treated with conservative management, including trans-arterial embolization to control the bleeding in one of the cases. All patients recovered without further incident. CONCLUSION: ERCP-related perforations may be difficult to diagnose by video endoscope and digital fluoroscope detection of retroperitoneal free air or contrast medium leakage can facilitate diagnosis. PMID:25400465

  19. Developing an instrument to assess the endoscopic severity of ulcerative colitis: the Ulcerative Colitis Endoscopic Index of Severity (UCEIS).

    PubMed

    Travis, Simon P L; Schnell, Dan; Krzeski, Piotr; Abreu, Maria T; Altman, Douglas G; Colombel, Jean-Frédéric; Feagan, Brian G; Hanauer, Stephen B; Lémann, Marc; Lichtenstein, Gary R; Marteau, Phillippe R; Reinisch, Walter; Sands, Bruce E; Yacyshyn, Bruce R; Bernhardt, Christian A; Mary, Jean-Yves; Sandborn, William J

    2012-04-01

    Variability in endoscopic assessment necessitates rigorous investigation of descriptors for scoring severity of ulcerative colitis (UC). To evaluate variation in the overall endoscopic assessment of severity, the intra- and interindividual variation of descriptive terms and to create an Ulcerative Colitis Endoscopic Index of Severity which could be validated. A two-phase study used a library of 670 video sigmoidoscopies from patients with Mayo Clinic scores 0-11, supplemented by 10 videos from five people without UC and five hospitalised patients with acute severe UC. In phase 1, each of 10 investigators viewed 16/24 videos to assess agreement on the Baron score with a central reader and agreed definitions of 10 endoscopic descriptors. In phase 2, each of 30 different investigators rated 25/60 different videos for the descriptors and assessed overall severity on a 0-100 visual analogue scale. κ Statistics tested inter- and intraobserver variability for each descriptor. A general linear mixed regression model based on logit link and β distribution of variance was used to predict overall endoscopic severity from descriptors. There was 76% agreement for 'severe', but 27% agreement for 'normal' appearances between phase I investigators and the central reader. In phase 2, weighted κ values ranged from 0.34 to 0.65 and 0.30 to 0.45 within and between observers for the 10 descriptors. The final model incorporated vascular pattern, (normal/patchy/complete obliteration) bleeding (none/mucosal/luminal mild/luminal moderate or severe), erosions and ulcers (none/erosions/superficial/deep), each with precise definitions, which explained 90% of the variance (pR(2), Akaike Information Criterion) in the overall assessment of endoscopic severity, predictions varying from 4 to 93 on a 100-point scale (from normal to worst endoscopic severity). The Ulcerative Colitis Endoscopic Index of Severity accurately predicts overall assessment of endoscopic severity of UC. Validity and responsiveness need further testing before it can be applied as an outcome measure in clinical trials or clinical practice.

  20. A technical review of flexible endoscopic multitasking platforms.

    PubMed

    Yeung, Baldwin Po Man; Gourlay, Terence

    2012-01-01

    Further development of advanced therapeutic endoscopic techniques and natural orifice translumenal endoscopic surgery (NOTES) requires a powerful flexible endoscopic multitasking platform. Medline search was performed to identify literature relating to flexible endoscopic multitasking platform from year 2004-2011 using keywords: Flexible endoscopic multitasking platform, NOTES, Instrumentation, Endoscopic robotic surgery, and specific names of various endoscopic multitasking platforms. Key articles from articles references were reviewed. Flexible multitasking platforms can be classified as either mechanical or robotic. Purely mechanical systems include the dual channel endoscope (DCE) (Olympus), R-Scope (Olympus), the EndoSamurai (Olympus), the ANUBIScope (Karl-Storz), Incisionless Operating Platform (IOP) (USGI), and DDES system (Boston Scientific). Robotic systems include the MASTER system (Nanyang University, Singapore) and the Viacath (Hansen Medical). The DCE, the R-Scope, the EndoSamurai and the ANUBIScope have integrated visual function and instrument manipulation function. The IOP and DDES systems rely on the conventional flexible endoscope for visualization, and instrument manipulation is integrated through the use of a flexible, often lockable, multichannel access device. The advantage of the access device concept is that it allows optics and instrument dissociation. Due to the anatomical constrains of the pharynx, systems are designed to have a diameter of less than 20 mm. All systems are controlled by traction cable system actuated either by hand or by robotic machinery. In a flexible system, this method of actuation inevitably leads to significant hysteresis. This problem will be accentuated with a long endoscope such as that required in performing colonic procedures. Systems often require multiple operators. To date, the DCE, the R-Scope, the IOP, and the Viacath system have data published relating to their application in human. Alternative forms of instrument actuation, camera control and master console ergonomics should be explored to improve instrument precision, sphere of action, size and minimize assistance required. Copyright © 2012 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  1. Low-cost endoscopic third ventriculostomy simulator with mimetic endoscope.

    PubMed

    Garling, Richard Justin; Jin, Xin; Yang, Jianzhong; Khasawneh, Ahmad H; Harris, Carolyn Anne

    2018-05-11

    OBJECTIVE Hydrocephalus affects approximately 1 in 500 people in the US, yet ventricular shunting, the gold standard of treatment, has a nearly 85% failure rate. Endoscopic third ventriculostomy (ETV) is an alternative surgical approach for a specific subset of hydrocephalic patients, but can be limited by the inability of neurosurgical residents to practice prior to patient contact. The goal of this study was to create an affordable ETV model and endoscope for resident training. METHODS Open-source software was used to isolate the skull and brain from the CT and MR images of a 2-year-old boy with hydrocephalus. A 3D printer created the skull and a 3D mold of the brain. A mixture of silicone and silicone tactile mutator was used to cast the brain mold prior to subsequent compression and shearing modulus testing. A mimetic endoscope was then created from basic supplies and a 3D printed frame. A small cohort of neurosurgical residents and attending physicians evaluated the ETV simulator with mimetic endoscope. RESULTS The authors successfully created a mimetic endoscope and ETV simulator. After compression and shearing modulus testing, a silicone/Slacker ratio between 10:6 and 10:7 was found to be similar to that of human brain parenchyma. Eighty-seven percent of participants strongly agreed that the simulator was useful for resident training, and 93% strongly agreed that the simulator helped them understand how to orient themselves with the endoscope. CONCLUSIONS The authors created an affordable (US$123, excluding 3D printer), easy-to-use ETV simulator with endoscope. Previous models have required expensive software and costly operative endoscopes that may not be available to most residents. Instead, this attempt takes advantage of open-source software for the manipulation and fabrication of a patient-specific mold. This model can assist with resident development, allowing them to safely practice use of the endoscope in ETV.

  2. Fecal level of calprotectin identifies histologic inflammation in patients with ulcerative colitis in clinical and endoscopic remission.

    PubMed

    Guardiola, Jordi; Lobatón, Triana; Rodríguez-Alonso, Lorena; Ruiz-Cerulla, Alexandra; Arajol, Claudia; Loayza, Carolina; Sanjuan, Xavier; Sánchez, Elena; Rodríguez-Moranta, Francisco

    2014-11-01

    Histologic recovery of patients with ulcerative colitis (UC) often is incomplete, even among those in clinical and endoscopic remission. Persistent active microscopic inflammation is associated with an increased risk of relapse and colorectal neoplasia. A high level of fecal calprotectin (FC) is a reliable marker of endoscopic lesions in patients with UC. We evaluated the accuracy of FC in identifying patients with UC in clinical and endoscopic remission who still have histologic features of inflammation. We performed a prospective observational study of 59 patients with UC in clinical and endoscopic remission undergoing colonoscopy. Several biopsy specimens were collected from each colonic segment. Endoscopic remission was defined as a Mayo endoscopic subscore with a grade of 0 or 1. Active histologic inflammation was defined by the presence of neutrophils infiltrating crypt epithelial cells. FC was determined by enzyme-linked immunosorbent assay analysis. Eighteen patients (30.5%) showed evidence of active histologic inflammation. Patients with active histologic inflammation had a significantly higher median level of FC (278 μg/g; interquartile range, 136-696 μg/g) than those without active histologic inflammation (68 μg/g; interquartile range, 30-172 μg/g) (P = .002). In multivariate analysis, the FC and Mayo endoscopic subscore (0 or 1) were each independent predictors of histologic inflammation. The level of FC identified active histologic inflammation in patients in clinical and endoscopic remission, with an area under the receiver operator characteristic curve value of 0.754. Histologic inflammation is common among patients with UC in clinical and endoscopic remission. Patients with histologic features of inflammation can be identified reliably based on their fecal level of calprotectin. Copyright © 2014 AGA Institute. Published by Elsevier Inc. All rights reserved.

  3. Endoscope-Assisted Transoral Fixation of Mandibular Condyle Fractures: Submandibular Versus Transoral Endoscopic Approach.

    PubMed

    Hwang, Na-Hyun; Lee, Yoon-Hwan; You, Hi-Jin; Yoon, Eul-Sik; Kim, Deok-Woo

    2016-07-01

    In recent years, endoscope-assisted transoral approach for condylar fracture treatment has attracted much attention. However, the surgical approach is technically challenging: the procedure requires specialized instruments and the surgeons experience a steep learning curve. During the transoral endoscopic (TE) approach several instruments are positioned through a narrow oral incision making endoscope maneuvering very difficult. For this reason, the authors changed the entry port of the endoscope from transoral to submandibular area through a small stab incision. The aim of this study is to assess the advantage of using the submandibular endoscopic intraoral approach (SEI).The SEI approach requires intraoral incision for fracture reduction and fixation, and 4 mm size submandibular stab incision for endoscope and traction wires. Fifteen patients with condyle neck and subcondyle fractures were operated under the submandibular approach and 15 patients with the same diagnosis were operated under the standard TE approach.The SEI approach allowed clear visualization of the posterior margin of the ramus and condyle, and the visual axis was parallel to the condyle ramus unit. The TE approach clearly shows the anterior margin of the condyle and the sigmoid notch. The surgical time of the SEI group was 128 minutes and the TE group was 120 minutes (P >0.05). All patients in the TE endoscope group were fixated with the trocar system, but only 2 lower neck fracture patients in the SEI group required a trocar. The other 13 subcondyle fractures were fixated with an angulated screw driver (P <0.05). There were no differences in complication and surgical outcomes.The submandibular endoscopic approach has an advantage of having more space with good visualization, and facilitated the use of an angulated screw driver.

  4. The Efficacy of Endoscopic Palliation of Obstructive Jaundice in Hepatocellular Carcinoma

    PubMed Central

    Park, Semi; Park, Jeong Youp; Chung, Moon Jae; Chung, Jae Bock; Park, Seung Woo; Han, Kwang-Hyub; Song, Si Young

    2014-01-01

    Purpose Obstructive jaundice in patients with hepatocellular carcinoma (HCC) is uncommon (0.5-13%). Unlike other causes of obstructive jaundice, the role of endoscopic intervention in obstructive jaundice complicated by HCC has not been clearly defined. The aim of this study was to evaluate the clinical characteristics of obstructive jaundice caused by HCC and predictive factors for successful endoscopic intervention. Materials and Methods From 1999 to 2009, 54 patients with HCC who underwent endoscopic intervention to relieve obstructive jaundice were included. We defined endoscopic intervention as a clinical success when the obstructive jaundice was relieved within 4 weeks. Results Clinical success was achieved in 23 patients (42.6%). Patients in the clinical success group showed better Child-Pugh liver function (C-P grade A or B/C; 17/6 vs. 8/20), lower total bilirubin levels (8.1±5.3 mg/dL vs. 23.1±10.4 mg/dL) prior to the treatment, and no history of alcohol consumption. The only factor predictive of clinical success by multivariate analysis was low total bilirubin level at the time of endoscopic intervention, regardless of history of alcohol consumption [odds ratio 1.223 (95% confidence interval, 1.071-1.396), p=0.003]. The cut-off value of pre-endoscopic treatment total bilirubin level was 12.8 mg/dL for predicting the clinical prognosis. Median survival after endoscopic intervention in the clinical success group was notably longer than that in the clinical failure group (5.6 months vs. 1.5 months, p≤0.001). Conclusion Before endoscopic intervention, liver function, especially total bilirubin level, should be checked to achieve the best clinical outcome. Endoscopic intervention can be helpful to relieve jaundice in well selected patients with HCC. PMID:25048484

  5. Prospective, randomized comparison of a prototype endoscope with deflecting working channels versus a conventional double-channel endoscope for rectal endoscopic submucosal dissection in an established experimental simulation model (with video).

    PubMed

    Jung, Yunho; Kato, Masayuki; Lee, Jongchan; Gromski, Mark A; Chuttani, Ram; Matthes, Kai

    2013-11-01

    A prototype endoscope was designed to improve visualization and dissection of tissue with the use of 2 working channels with different deflections. To evaluate the efficacy and operability of a prototype endoscope in comparison with a conventional double-channel endoscope for rectal endoscopic submucosal dissection (ESD). Randomized, prospective, controlled, ex vivo study. Academic medical center. A total of 80 standardized artificial lesions measuring 3 × 3 cm were created approximately 5 cm from the anal verge in fresh ex vivo porcine colorectal specimens. Two endoscopists each completed 20 cases with the prototype endoscope and 20 cases with the conventional endoscope. An independent observer recorded procedure time, specimen size, en bloc resection, and perforation rate. For the ESD novice, the mean submucosal dissection time (10.5 ± 3.8 vs 14.9 ± 7.3 minutes; P = .024) and total procedure time (18.1 ± 5.2 vs 23.6 ± 8.2 minutes; P = .015) were significantly shorter in the prototype group in comparison with the conventional group. For the ESD expert, there was no significant difference between the mean circumferential resection, submucosal dissection, and total procedure time (prototype group 14.2 ± 6.0 minutes, conventional group 14.2 ± 8.8 minutes; P = .992). The overall perforation and en bloc resection rates were not significantly different between groups. Ex vivo study. In this ex vivo prospective comparison study, there was a technical advantage for the ESD novice with the prototype endoscope that resulted in a shorter procedure time, which was not observed for cases performed by the ESD expert. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  6. Combining eastern and western practices for safe and effective endoscopic resection of large complex colorectal lesions.

    PubMed

    Emmanuel, Andrew; Gulati, Shraddha; Burt, Margaret; Hayee, Bu'Hussain; Haji, Amyn

    2018-05-01

    Endoscopic resection of large colorectal polyps is well established. However, significant differences in technique exist between eastern and western interventional endoscopists. We report the results of endoscopic resection of large complex colorectal lesions from a specialist unit that combines eastern and western techniques for assessment and resection. Endoscopic resections of colorectal lesions of at least 2 cm were included. Lesions were assessed using magnification chromoendoscopy supplemented by colonoscopic ultrasound in selected cases. A lesion-specific approach to resection with endoscopic mucosal resection or endoscopic submucosal dissection (ESD) was used. Surveillance endoscopy was performed at 3 (SC1) and 12 (SC2) months. Four hundred and sixty-six large (≥20 mm) colorectal lesions (mean size 54.8 mm) were resected. Three hundread and fifty-six were resected using endoscopic mucosal resection and 110 by ESD or hybrid ESD. Fifty-one percent of lesions had been subjected to previous failed attempts at resection or heavy manipulation (≥6 biopsies). Nevertheless, endoscopic resection was deemed successful after an initial attempt in 98%. Recurrence occurred in 15% and could be treated with endoscopic resection in most. Only two patients required surgery for perforation. Nine patients had postprocedure bleeding; only two required endoscopic clips. Ninety-six percent of patients without invasive cancer were free from recurrence and had avoided surgery at last follow-up. Combining eastern and western practices for assessment and resection results in safe and effective organ-conserving treatment of complex colorectal lesions. Accurate assessment before and after resection using magnification chromoendoscopy and a lesion-specific approach to resection, incorporating ESD where appropriate, are important factors in achieving these results.

  7. Comparison of 3 mm versus 4 mm rigid endoscope in diagnostic nasal endoscopy.

    PubMed

    Neel, Gregory S; Kau, Ryan L; Bansberg, Stephen F; Lal, Devyani

    2017-03-01

    Compare nasal endoscopy with 3 mm versus conventional 4 mm rigid 30° endoscopes for visualization, patient comfort, and examiner ease. Ten adults with no previous sinus surgery underwent bilateral nasal endoscopy with both 4 mm and 3 mm endoscopes (resulting in 20 paired nasal endoscopies). Visualization, patient discomfort and examiner's difficulty were assessed with every endoscopy. Sino-nasal structures were checked on a list if visualized satisfactorily. Patients rated discomfort on a standardized numerical pain scale (0-10). Examiners rated difficulty of examination on a scale of 1-5 (1 = easiest). Visualization with 3 mm endoscope was superior for the sphenoid ostium ( P  = 0.002), superior turbinate ( P  = 0.007), spheno-ethmoid recess ( P  = 0.006), uncinate process ( P  = 0.002), cribriform area ( P  = 0.007), and Valve of Hasner ( P  = 0.002). Patient discomfort was not significantly different for 3 mm vs. 4 mm endoscopes but correlated with the examiners' assessment of difficulty ( r  = 0.73). The examiner rated endoscopy with 4 mm endoscopes more difficult ( P  = 0.027). The 3 mm endoscope was superior in visualizing the sphenoid ostium, superior turbinate, spheno-ethmoid recess, uncinate process, cribriform plate, and valve of Hasner. It therefore may be useful in assessment of spheno-ethmoid recess, nasolacrimal duct, and cribriform area pathologies. Overall, patients tolerated nasal endoscopy well. Though patient discomfort was not significantly different between the endoscopes, most discomfort with 3 mm endoscopes was noted while examining structures difficult to visualize with the 4 mm endoscope. Patients' discomfort correlated with the examiner's assessment of difficulty.

  8. Lower incidence of complications in endoscopic nasobiliary drainage for hilar cholangiocarcinoma.

    PubMed

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Kuwatani, Masaki; Haba, Shin; Kudo, Taiki; Taya, Yoko A; Kawahata, Shuhei; Kubota, Yoshimasa; Kubo, Kimitoshi; Eto, Kazunori; Ehira, Nobuyuki; Yamato, Hiroaki; Onodera, Manabu; Sakamoto, Naoya

    2016-05-10

    To identify the most effective endoscopic biliary drainage technique for patients with hilar cholangiocarcinoma. In total, 118 patients with hilar cholangiocarcinoma underwent endoscopic management [endoscopic nasobiliary drainage (ENBD) or endoscopic biliary stenting] as a temporary drainage in our institution between 2009 and 2014. We retrospectively evaluated all complications from initial endoscopic drainage to surgery or palliative treatment. The risk factors for biliary reintervention, post-endoscopic retrograde cholangiopancreatography (post-ERCP) pancreatitis, and percutaneous transhepatic biliary drainage (PTBD) were also analyzed using patient- and procedure-related characteristics. The risk factors for bilateral drainage were examined in a subgroup analysis of patients who underwent initial unilateral drainage. In total, 137 complications were observed in 92 (78%) patients. Biliary reintervention was required in 83 (70%) patients. ENBD was significantly associated with a low risk of biliary reintervention [odds ratio (OR) = 0.26, 95%CI: 0.08-0.76, P = 0.012]. Post-ERCP pancreatitis was observed in 19 (16%) patients. An absence of endoscopic sphincterotomy was significantly associated with post-ERCP pancreatitis (OR = 3.46, 95%CI: 1.19-10.87, P = 0.023). PTBD was required in 16 (14%) patients, and Bismuth type III or IV cholangiocarcinoma was a significant risk factor (OR = 7.88, 95%CI: 1.33-155.0, P = 0.010). Of 102 patients with initial unilateral drainage, 49 (48%) required bilateral drainage. Endoscopic sphincterotomy (OR = 3.24, 95%CI: 1.27-8.78, P = 0.004) and Bismuth II, III, or IV cholangiocarcinoma (OR = 34.69, 95%CI: 4.88-736.7, P < 0.001) were significant risk factors for bilateral drainage. The endoscopic management of hilar cholangiocarcinoma is challenging. ENBD should be selected as a temporary drainage method because of its low risk of complications.

  9. Single incision endoscopic surgery for gynaecomastia.

    PubMed

    Jarrar, G; Peel, A; Fahmy, R; Deol, H; Salih, V; Mostafa, A

    2011-09-01

    Surgical excision has been an effective treatment for gynaecomastia. Recently, there has been a shift from the open approach to minimally invasive techniques. In this report we describe our technique which includes endoscopic excision and/or liposuction of gynaecomastia via a single lateral chest wall incision. Between May 2007 and April 2010, a total of 12 gynaecomastia patients were treated with liposuction and/or endoscopic excision. Patients were divided into 3 groups: group I; liposuction only, group II; endoscopic excision plus liposuction and group III; endoscopic excision only. One 15 mm incision was made laterally at the anterior axillary line. A vacuum assisted liposuction removing the fatty tissue was performed. Then endoscopic excision of the remaining fibroglandular tissue was done under vision through the same incision. The parynchyma was then dissected into small pieces and pulled out. Group I had liposuction only (n = 4), group II had liposuction combined with endoscopic excision (n = 7) (58%) while group III had endoscopic excision only (n = 1). The mean operative time for liposuction and endoscopic excision was 58 min for each side. Mean hospital stay was 1.4 days. Postoperative complications included infection with abscess formation and one patient had seroma. Mean follow-up was 56 weeks. Eleven out of twelve patients (92%) were satisfied with their results. Long-term follow-up showed that results were stable over time, and no revisions were necessary. Endoscopic excision of gynaecomastia through a single lateral chest wall incision is a minimally invasive effective and safe technique for the management of gynaecomastia, with excellent aesthetic results and an acceptable complication rate. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Clinical, biological, and endoscopic picture of attacks of Crohn's disease. Evolution on prednisolone. Groupe d'Etude Thérapeutique des Affections Inflammatoires Digestives.

    PubMed

    Modigliani, R; Mary, J Y; Simon, J F; Cortot, A; Soule, J C; Gendre, J P; Rene, E

    1990-04-01

    One hundred forty-two patients with active colonic or ileocolonic Crohn's disease were included in a multicenter prospective study. Data collection included 28 clinical, biological, and endoscopic items; the latter were recorded according to a standardized colonoscopic protocol; a previously validated endoscopic index of severity was calculated. Oral prednisolone (1 mg/kg body wt per day) was started and maintained until clinical remission and for at least 3 and at most 7 wk. A second clinical biological and endoscopic evaluation was then performed. At initial colonoscopy, mucosal lesions were, by decreasing order of frequency, superficial ulcerations, deep ulcerations, mucosal edema, erythema, pseudopolyps, aphthoid ulcers, ulcerated stenosis, and nonulcerated stenosis (93%, 74%, 48%, 44%, 41%, 35%, 10%, 8%, and 2% of cases, respectively). No correlation was found between the clinical activity index and any of the endoscopical data (lesion frequency and surface, endoscopic severity index). Ninety-two percent of patients underwent clinical remission within 7 wk of treatment. None of the 28 clinical biological and endoscopical items collected just before treatment could predict clinical response to steroids. Only 38 of the 131 patients in clinical remission were also in endoscopic remission. In conclusion, (a) the description and severity of colonoscopic lesions in active Crohn's disease have been quantified; (b) no correlation exists between clinical severity and nature, surface, or severity of endoscopic lesions; (c) Oral prednisolone (1 mg/kg body wt per day) induces a clinical remission in 92% of patients within 7 wk; (d) resistance to steroids cannot be predicted from the data collected before treatment onset; and (e) only 29% of patients in clinical remission also achieve endoscopic remission.

  11. Endoscopic Endonasal Versus Microscopic Transsphenoidal Surgery for Recurrent and/or Residual Pituitary Adenomas.

    PubMed

    Esquenazi, Yoshua; Essayed, Walid I; Singh, Harminder; Mauer, Elizabeth; Ahmed, Mudassir; Christos, Paul J; Schwartz, Theodore H

    2017-05-01

    Surgery for recurrent/residual pituitary adenomas is increasingly being performed through endoscopic surgery. Whether this new technology has altered the indications and outcomes of surgery is unknown. We conducted a systematic review and meta-analysis of published studies to compare the indications and outcomes between microscopic and endoscopic approaches. A PubMed search was conducted (1985-2015) to identify surgical series of endoscopic endonasal and microscopic transsphenoidal resection of residual or recurrent pituitary adenomas. Data were extracted regarding tumor characteristics, surgical treatment, extent of resection, endocrine remission, visual outcome, and complications. Twenty-one studies met inclusion criteria. A total of 292 patients were in the endoscopic group, and 648 patients were in the microscopic group. Endoscopic cases were more likely nonfunctional (P < 0.001) macroadenomas (P < 0.001) with higher rates of cavernous sinus invasion (P = 0.012). The pooled rate of gross total tumor resection was 53.5% for the endoscopic group and 46.6% for the microscopic group. Endocrine remission was achieved in 53.0% and 46.7% of patients, and visual improvement occurred in 73.2% and 49.6% for the endoscopic and microscopic groups. Cerebrospinal fluid leak and pituitary insufficiency were higher in the endoscopic group. This meta-analysis indicates that the use of the endoscope to reoperate on residual or recurrent adenomas has only led to modest increases in resection rates. However, larger more complex cases are being tackled, so direct comparisons are misleading. The most dramatic change has been in visual improvement along with modest increases in risk. Reoperation for recurrent or residual adenomas is a safe and effective treatment option. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Endoscopic and interstitial Nd:YAG laser therapy to control duodenal and periampullary carcinoma

    NASA Astrophysics Data System (ADS)

    Barr, Hugh; Fowler, Aiden L.

    1996-12-01

    Duodenal and periampullary cancer present with jaundice, bleeding and obstruction. Many patients are unsuitable for radical surgery. Endoscopic palliation of jaundice can be achieved using endoscopic sphincterotomy or stent insertion. However, the problems of bleeding and obstruction can be difficult to manage. Ten patients were treated using superficial Nd:YAG laser ablation and lower power interstitial laser therapy. After initial outpatient endoscopic therapy, treatment was repeated at 4 monthly intervals to prevent recurrent symptoms. Bleeding was controlled in all patients and only one patient developed obstructive symptoms between treatment sessions. This responded to further endoscopic laser therapy. The median survival was 21 months. Laser treated patients were compared with a historical series of 22 patients treated with endoscopic sphincterotomy or stent insertion. The complication rate was less in patients treated with the laser.

  13. [Liver Abscess Secondary to Perforation after Duodenal Endoscopic Resection].

    PubMed

    Choi, Seung Ho; Kim, Su Jin; Kang, Dae Hwan; Kim, Hyung Wook; Choi, Cheol Woong; Kim, Tae Un; Lee, Jeong Seok; Ko, Ji Hwan

    2018-05-25

    Duodenal perforation is a complication of endoscopic mucosal resection. Liver abscess secondary to iatrogenic perforation is extremely rare. A 43-year-old female visited the hospital to remove a sub-epithelial tumor on the duodenal bulb. After endoscopic mucosal resection with band ligation, duodenal perforation occurred. Endoscopic closure was performed successfully using a clipping device to manage duodenal perforation. After 4 weeks, the patient visited our outpatient clinic due to abdominal pain and fever. Abdominal computed tomography showed liver abscess that involved segment three. Liver abscess was resolved with a 10-week antibiotic treatment. To the best of our knowledge, no case of liver abscess secondary to duodenal perforation by endoscopic resection was reported to date in Korea. Here, we report a case of liver abscess caused by a duodenal perforation after endoscopic mucosal resection.

  14. Investigating the failure of repeated standard cleaning and disinfection of a Pseudomonas aeruginosa-infected pancreatic and biliary endoscope.

    PubMed

    Qiu, Lijun; Zhou, Zhihui; Liu, Qifang; Ni, Yuhua; Zhao, Feng; Cheng, Hao

    2015-08-01

    Digestive endoscopy is an important technique for the diagnosis and treatment of digestive system disease. To assure medical safety, a digestive endoscope must be cleaned and disinfected before its use in an operation on the next patient. The most common treatment procedure on a digestive endoscope is high-level disinfection. The potential risk associated with digestive endoscopes is always the focus of endoscopic management in clinical practice. In this study, a polluted pancreatic and biliary endoscope after surgery was cleaned and disinfected multiple times with the standard procedure but still tested positive for Pseudomonas aeruginosa culture, which is very rare and has not been reported in China or abroad. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  15. Real-time endoscopic image orientation correction system using an accelerometer and gyrosensor.

    PubMed

    Lee, Hyung-Chul; Jung, Chul-Woo; Kim, Hee Chan

    2017-01-01

    The discrepancy between spatial orientations of an endoscopic image and a physician's working environment can make it difficult to interpret endoscopic images. In this study, we developed and evaluated a device that corrects the endoscopic image orientation using an accelerometer and gyrosensor. The acceleration of gravity and angular velocity were retrieved from the accelerometer and gyrosensor attached to the handle of the endoscope. The rotational angle of the endoscope handle was calculated using a Kalman filter with transmission delay compensation. Technical evaluation of the orientation correction system was performed using a camera by comparing the optical rotational angle from the captured image with the rotational angle calculated from the sensor outputs. For the clinical utility test, fifteen anesthesiology residents performed a video endoscopic examination of an airway model with and without using the orientation correction system. The participants reported numbers written on papers placed at the left main, right main, and right upper bronchi of the airway model. The correctness and the total time it took participants to report the numbers were recorded. During the technical evaluation, errors in the calculated rotational angle were less than 5 degrees. In the clinical utility test, there was a significant time reduction when using the orientation correction system compared with not using the system (median, 52 vs. 76 seconds; P = .012). In this study, we developed a real-time endoscopic image orientation correction system, which significantly improved physician performance during a video endoscopic exam.

  16. Robotic and endoscopic transaxillary thyroidectomies may be cost prohibitive when compared to standard cervical thyroidectomy: a cost analysis.

    PubMed

    Cabot, Jennifer C; Lee, Cho Rok; Brunaud, Laurent; Kleiman, David A; Chung, Woong Youn; Fahey, Thomas J; Zarnegar, Rasa

    2012-12-01

    This study presents a cost analysis of the standard cervical, gasless transaxillary endoscopic, and gasless transaxillary robotic thyroidectomy approaches based on medical costs in the United States. A retrospective review of 140 patients who underwent standard cervical, transaxillary endoscopic, or transaxillary robotic thyroidectomy at 2 tertiary centers was conducted. The cost model included operating room charges, anesthesia fee, consumables cost, equipment depreciation, and maintenance cost. Sensitivity analyses assessed individual cost variables. The mean operative times for the standard cervical, transaxillary endoscopic, and transaxillary robotic approaches were 121 ± 18.9, 185 ± 26.0, and 166 ± 29.4 minutes, respectively. The total cost for the standard cervical, transaxillary endoscopic, and transaxillary robotic approaches were $9,028 ± $891, $12,505 ± $1,222, and $13,670 ± $1,384, respectively. Transaxillary approaches were significantly more expensive than the standard cervical technique (standard cervical/transaxillary endoscopic, P < .0001; standard cervical/transaxillary robotic, P < .0001; and transaxillary endoscopic/transaxillary robotic, P = .001). The transaxillary and standard cervical techniques became equivalent in cost when transaxillary endoscopic operative time decreased to 111 minutes and transaxillary robotic operative time decreased to 68 minutes. Increasing the case load did not resolve the cost difference. Transaxillary endoscopic and transaxillary robotic thyroidectomies are significantly more expensive than the standard cervical approach. Decreasing operative times reduces this cost difference. The greater expense may be prohibitive in countries with a flat reimbursement schedule. Copyright © 2012 Mosby, Inc. All rights reserved.

  17. Endoscopic stent suture fixation for prevention of esophageal stent migration during prolonged dilatation for achalasia treatment.

    PubMed

    Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F

    2017-04-01

    The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Elimination of high titre HIV from fibreoptic endoscopes.

    PubMed

    Hanson, P J; Gor, D; Jeffries, D J; Collins, J V

    1990-06-01

    Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the kinetics of elimination of HIV from endoscope surfaces, we artificially contaminated the suction-biopsy channels of five Olympus GIF XQ20 endoscopes with high titre HIV in serum. The air and water channels of two instruments were similarly contaminated. Contamination was measured by irrigating channels with viral culture medium and collecting 3 ml at the distal end for antigen immunoassay. Endoscopes were then cleaned manually in neutral detergent according to the manufacturer's recommendations and disinfected in 2% alkaline glutaraldehyde (Cidex, Surgikos) for two, four, and ten minutes. Contamination with HIV antigens was measured before and after cleaning and after each period of disinfection. Initial contamination comprised 4.8 x 10(4) to 3.5 x 10(6) pg HIV antigen/ml. Cleaning in detergent achieved a reduction to 165 pg/ml (99.93%) on one endoscope and to undetectable levels (100%) on four. After two minutes in alkaline glutaraldehyde all samples were negative and remained negative after the longer disinfection times. Air and water channels, where contaminated, were tested after 10 minutes' disinfection and were negative. These findings underline the importance of cleaning in removing HIV from endoscope and indicate that the use of dedicated equipment and long disinfection times are unnecessary.

  19. [Tracheotomy-endoscop for dilatational percutaneous tracheotomy (TED)].

    PubMed

    Klemm, Eckart

    2006-09-01

    While surgical tracheotomies are currently performed using state-of-the-art operative techniques, percutaneous dilatational tracheostomy (PDT) is in a rapidly evolving state with regard to its technology and the number of techniques available. This has resulted in a range of new complications that are difficult to quantify on a scientific basis, given the fact that more than half of the patients who are tracheotomized in intensive care units die from their underlying disease. The new Tracheotomy Endoscope (TED) is designed to help prevent serious complications in dilatational tracheotomies and facilitate their management. The endoscope has been specifically adapted to meet the require-ments of percutaneous dilatational tracheotomies. It is fully compatible with all current techniques of PDT. The method is easy to learn. The percutaneous dilatational tracheotomy with the Tracheotomy Endoscope is a seven-step procedure: Advantages of the Tracheotomy Endoscope: Injuries to the posterior tracheal wall ar impossible (tracheoesophageal fistulas, pneumothorax). Minor bleeding sites on the tracheal mucosa can be controlled with a specially curved suction-coagulation tube introudeced through the Tracheotomy Endoscope. In cases with heavy bleeding and a risk of aspiration, the rigid indwelling Tracheotomy Endoscope provides a secure route for reintubating the patient with a cuffed endotracheal tube. It also allows for rapid conversion to an open surgical procedure if necessary. All the parts are easy to clean and are autoclavable. This type of endoscopically guided PDT creates an optimal link between the specialties of intensive care medicine and otorhinolaryngology. The Tracheotomy Endoscope (TED) increases the standard of safety in PDT.

  20. Surgical management of failed endoscopic treatment of pancreatic disease.

    PubMed

    Evans, Kimberly A; Clark, Colby W; Vogel, Stephen B; Behrns, Kevin E

    2008-11-01

    Endoscopic therapy of acute and chronic pancreatitis has decreased the need for operative intervention. However, a significant proportion of patients treated endoscopically require definitive surgical management for persistent symptoms. Our aim was to determine which patients are likely to fail with endoscopic therapy, and to assess the clinical outcome of surgical management. Patients were identified using ICD-9 codes for pancreatic disease as well as CPT codes for endoscopic therapy followed by surgery. Patients with documented acute or chronic pancreatitis treated endoscopically prior to surgical therapy were included (N = 88). The majority of patients (65%) exhibited chronic pancreatitis due to alcohol abuse. Common indicators for surgery were: persistent symptoms, anatomy not amenable to endoscopic treatment and unresolved common bile duct or pancreatic duct strictures. Surgical salvage procedures included internal drainage of a pseudocyst or an obstructed pancreatic duct (46%), debridement of peripancreatic fluid collections (25%), and pancreatic resection (31%). Death occurred in 3% of patients. The most common complications were hemorrhage (16%), wound infection (13%), and pulmonary complications (11%). Chronic pancreatitis with persistent symptoms is the most common reason for pancreatic surgery following endoscopic therapy. Surgical salvage therapy can largely be accomplished by drainage procedures, but pancreatic resection is common. These complex procedures can be performed with acceptable mortality but also with significant risk for morbidity.

  1. Endoscope disinfection and its pitfalls--requirement for retrograde surveillance cultures.

    PubMed

    Buss, A J; Been, M H; Borgers, R P; Stokroos, I; Melchers, W J; Peters, F T; Limburg, A J; Degener, J E

    2008-04-01

    Several endoscopy-related outbreaks of infection have been reported in recent years. For early recognition of inadequate disinfection of endoscopes we designed a microbiological surveillance system to evaluate the efficacy of the cleaning and disinfection procedure, and to trace disinfection problems to individual endoscopes or washer-disinfectors. Our surveillance protocol included anterograde and retrograde sampling, a decision algorithm, genetic fingerprinting, and scanning electron microscopy. Over a period of 29 months we found an increasing number of patient-ready endoscopes testing positive for Candida species other than albicans, especially C. parapsilosis. These yeasts were also isolated from the washer-disinfectors. The number of positive tests for Candida species varied from 1 out of 21 to 14 out of 27 samples from nine frequently used endoscopes. The number of colony-forming units per milliliter ranged from 1 - 10 to 3000 for endoscopes and 0.002 to 0.06 for the washer disinfectors. DNA fingerprinting was not able to discriminate different strains within C. parapsilosis. Our protocol was able to detect a structural problem in the endoscope disinfection process. Retrograde sampling was crucial for this purpose, because it has much higher sensitivity than anterograde sampling. Endoscopes with damaged working channels are probably the source of the contamination problem with Candida species.

  2. Endoscopic full-thickness resection of gastric subepithelial tumors: a single-center series.

    PubMed

    Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; von Renteln, Daniel; Muehleisen, Helmut; Caca, Karel

    2015-02-01

    Endoscopic full-thickness resection of gastric subepithelial tumors with a full-thickness suturing device has been described as feasible in two small case series. The aim of this study was to evaluate the efficacy, safety, and clinical outcome of this resection technique. After 31 patients underwent endoscopic full-thickness resection, the data were analyzed retrospectively. Before snare resection, 1 to 3 full-thickness sutures were placed underneath each tumor with a device originally designed for endoscopic anti-reflux therapy. All tumors were resected successfully. Bleeding occurred in 12 patients (38.7 %); endoscopic hemostasis could be achieved in all cases. Perforation occurred in 3 patients (9.6 %), and all perforations could be managed endoscopically. Complete resection was histologically confirmed in 28 of 31 patients (90.3 %). Mean follow-up was 213 days (range, 1 - 1737), and no tumor recurrences were observed. Endoscopic full-thickness resection of gastric subepithelial tumors with the suturing technique described above is feasible and effective. After the resection of gastrointestinal stromal tumors (GISTs), we did not observe any recurrences during follow-up, indicating that endoscopic full-thickness resection may be an alternative to surgical resection for selected patients. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Simethicone residue remains inside gastrointestinal endoscopes despite reprocessing.

    PubMed

    Ofstead, Cori L; Wetzler, Harry P; Johnson, Ellen A; Heymann, Otis L; Maust, Thomas J; Shaw, Michael J

    2016-11-01

    During a study designed to assess endoscope reprocessing effectiveness, a borescope was used to examine lumens and ports. Cloudy, white, viscous fluid was observed inside fully reprocessed gastroscopes and colonoscopes. This fluid resembled simethicone, which is commonly administered to reduce foam and bubbles that impede visualization during gastrointestinal endoscopy. This article describes methods used to determine whether the observed fluid contained simethicone. Photographs of residual fluid were taken using a borescope. Sterile cotton-tipped swabs were used to collect samples of fluid observed in 3 endoscope ports. Samples were evaluated using Fourier transform infrared spectroscopy (FTIR)-attenuated total reflection analysis. Residual fluid was observed inside 19 of 20 endoscopes. Fluid photographed in 8 endoscopes resembled simethicone solutions. FTIR analysis confirmed the presence of simethicone in 2 endoscopes. Fluid containing simethicone remained inside endoscopes despite reprocessing. Simethicone is an inert, hydrophobic substance that may reduce reprocessing effectiveness. Simethicone solutions commonly contain sugars and thickeners, which may contribute to microbial growth and biofilm development. Studies are needed to assess the prevalence of residual moisture and simethicone in endoscopes and determine the impact on reprocessing effectiveness. We recommend minimizing the use of simethicone pending further research into its safety. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Direct peroral cholangioscopy using an ultraslim upper endoscope for biliary lesions.

    PubMed

    Omuta, Shigefumi; Maetani, Iruru; Ukita, Takeo; Nambu, Tomoko; Gon, Katsushige; Shigoka, Hiroaki; Saigusa, Yoshinori; Saito, Michihiro

    2014-02-01

    The development of direct peroral cholangioscopy (DPOC) using an ultraslim endoscope simplifies biliary cannulation. The conventional techniques are cumbersome to perform and require advanced skills. The recent introduction of the guidewires and balloons has improved the therapeutic outcomes. Here we describe an effective and easier method for performing DPOC using an ultraslim upper endoscope. Indications for DPOC were the presence of stones on follow-up of patients who had previously undergone complete sphincteroplasty, including endoscopic sphincterotomy or endoscopic papillary large balloon dilatation. Fifteen patients underwent DPOC. An ultraslim endoscope was inserted perorally and was advanced into the major papilla. The ampulla of Vater was visualized by retroflexing the endoscope in the distal second portion of the duodenum, and then DPOC was performed using a wire-guided cannulation technique with an anchored intraductal balloon catheter. One patient failed in the treatment due to looping of the endoscope in the fornix of the stomach. Fourteen (93.3%) were successfully treated with our modified DPOC technique. Only one patient (6.7%) experienced an adverse event (pancreatitis) who responded well to conservative management. Residual stones of the common bile duct were completely removed in 3 patients. The modified method of DPOC is simple, safe and easy to access the bile duct.

  5. Advances in endoscopic management of biliary complications after living donor liver transplantation: Comprehensive review of the literature

    PubMed Central

    Shin, Milljae; Joh, Jae-Won

    2016-01-01

    Apart from noticeable improvements in surgical techniques and immunosuppressive agents, biliary complications remain the major causes of morbidity and mortality after living donor liver transplantation (LDLT). Bile leakage and stricture are the predominant complications. The reported incidence of biliary complications is 15%-40%, and these are known to occur more frequently in living donors than in deceased donors. Despite the absence of a confirmed therapeutic algorithm, many approaches have been used for treatment, including surgical, endoscopic, and percutaneous transhepatic techniques. In recent years, nonsurgical approaches have largely replaced reoperation. Among these, the endoscopic approach is currently the preferred initial treatment for patients who undergo duct-to-duct biliary reconstruction. Previously, endoscopic management was achieved most optimally through balloon dilatation and single or multiple stents placement. Recently, there have been significant developments in endoscopic devices, such as novel biliary stents, as well as advances in endoscopic technologies, including deep enteroscopy, the rendezvous technique, magnetic compression anastomosis, and direct cholangioscopy. These developments have resulted in almost all patients being managed by the endoscopic approach. Multiple recent publications suggest superior long-term results, with overall success rates ranging from 58% to 75%. This article summarizes the advances in endoscopic management of patients with biliary complications after LDLT. PMID:27468208

  6. Feasibility of Piezoelectric Endoscopic Transsphenoidal Craniotomy: A Cadaveric Study

    PubMed Central

    Tomazic, Peter Valentin; Gellner, Verena; Koele, Wolfgang; Hammer, Georg Philipp; Braun, Eva Maria; Gerstenberger, Claus; Clarici, Georg; Holl, Etienne; Braun, Hannes; Stammberger, Heinz; Mokry, Michael

    2014-01-01

    Objective. Endoscopic transsphenoidal approach has become the gold standard for surgical treatment of treating pituitary adenomas or other lesions in that area. Opening of bony skull base has been performed with burrs, chisels, and hammers or standard instruments like punches and circular top knives. The creation of primary bone flaps—as in external craniotomies—is difficult.The piezoelectric osteotomes used in the present study allows creating a bone flap for endoscopic transnasal approaches in certain areas. The aim of this study was to prove the feasibility of piezoelectric endoscopic transnasal craniotomies. Study Design. Cadaveric study. Methods. On cadaveric specimens (N = 5), a piezoelectric system with specially designed hardware for endonasal application was applied and endoscopic transsphenoidal craniotomies at the sellar floor, tuberculum sellae, and planum sphenoidale were performed up to a size of 3–5 cm2. Results. Bone flaps could be created without fracturing with the piezoosteotome and could be reimplanted. Endoscopic handling was unproblematic and time required was not exceeding standard procedures. Conclusion. In a cadaveric model, the piezoelectric endoscopic transsphenoidal craniotomy (PETC) is technically feasible. This technique allows the surgeon to create a bone flap in endoscopic transnasal approaches similar to existing standard transcranial craniotomies. Future trials will focus on skull base reconstruction using this bone flap. PMID:24689037

  7. A wireless narrowband imaging chip for capsule endoscope.

    PubMed

    Lan-Rong Dung; Yin-Yi Wu

    2010-12-01

    This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis.

  8. 3-D endoscopic imaging using plenoptic camera.

    PubMed

    Le, Hanh N D; Decker, Ryan; Opferman, Justin; Kim, Peter; Krieger, Axel; Kang, Jin U

    2016-06-01

    Three-dimensional endoscopic imaging using plenoptic technique combined with F-matching algorithm has been pursued in this study. A custom relay optics was designed to integrate a commercial surgical straight endoscope with a plenoptic camera.

  9. Role of endoscopic retrograde cholangiopancreatography in the management of benign biliary strictures: What’s new?

    PubMed Central

    Ferreira, Rosa; Loureiro, Rui; Nunes, Nuno; Santos, António Alberto; Maio, Rui; Cravo, Marília; Duarte, Maria Antónia

    2016-01-01

    Benign biliary strictures comprise a heterogeneous group of diseases. The most common strictures amenable to endoscopic treatment are post-cholecystectomy, post-liver transplantation, related to primary sclerosing cholangitis and to chronic pancreatitis. Endoscopic treatment of benign biliary strictures is widely used as first line therapy, since it is effective, safe, noninvasive and repeatable. Endoscopic techniques currently used are dilation, multiple plastic stents insertion and fully covered self-expandable metal stents. The main indication for dilation alone is primary sclerosing cholangitis related strictures. In the vast majority of the remaining cases, temporary placement of multiple plastic stents with/without dilation is considered the treatment of choice. Although this approach is effective, it requires multiple endoscopic sessions due to the short duration of stent patency. Fully covered self-expandable metal stents appear as a good alternative to plastic stents, since they have an increased radial diameter, longer stent patency, easier insertion technique and similar efficacy. Recent advances in endoscopic technique and various devices have allowed successful treatment in most cases. The development of novel endoscopic techniques and devices is still ongoing. PMID:26962404

  10. Transnasal endoscopic medial maxillectomy in recurrent maxillary sinus inverted papilloma.

    PubMed

    Kamel, Reda H; Abdel Fattah, Ahmed F; Awad, Ayman G

    2014-12-01

    Maxillary sinus inverted papilloma entails medial maxillectomy and is associated with high incidence of recurrence. To study the impact of prior surgery on recurrence rate after transnasal endoscopic medial maxillectomy. Eighteen patients with primary and 33 with recurrent maxillary sinus inverted papilloma underwent transnasal endoscopic medial maxillectomy. Caldwell-Luc operation was the primary surgery in 12 patients, transnasal endoscopic resection in 20, and midfacial degloving technique in one. The follow-up period ranged between 2 to 19.5 years with an average of 8.8 years. Recurrence was detected in 8/51 maxillary sinus inverted papilloma patients (15.7 %), 1/18 of primary cases (5.5 %), 7/33 of recurrent cases (21.2 %); 3/20 of the transnasal endoscopic resection group (15%) and 4/12 of the Caldwell-Luc group (33.3%). Redo transnasal endoscopic medial maxillectomy was followed by a single recurrence in the Caldwell-Luc group (25%), and no recurrence in the other groups. Recurrence is more common in recurrent maxillary sinus inverted papilloma than primary lesions. Recurrent maxillary sinus inverted papilloma after Caldwell-Luc operation has higher incidence of recurrence than after transnasal endoscopic resection.

  11. The universal serial bus endoscope: design and initial clinical experience.

    PubMed

    Hernandez-Zendejas, Gregorio; Dobke, Marek K; Guerrerosantos, Jose

    2004-01-01

    Endoscopic forehead lift is a well-established procedure in aesthetic plastic surgery. Many agree that currently available video-endoscopic equipment is bulky, multipieced and sometimes cumbersome in the operating theater. A novel system, the Universal Serial Bus Endoscope (USBE) was designed to simplify and reduce the number of necessary equipment pieces in the endoscopic setup. The USBE is attached by a single cable to a Universal Serial Bus (USB) port of a laptop computer. A built-in miniaturized cold light source provides illumination. A built-in digital camera chip enables procedure recording. The real-time images and movies obtained with USBE are displayed on the computer's screen and recorded on the laptop's hard disk drive. In this study, 25 patients underwent endoscopic browlift using the USBE system to test its clinical usefulness, all with good results and without complications or need for revision. The USBE was found to be reliable and easier to use than current video-endoscope equipment. The operative time needed to complete the procedure by the authors was reduced approximately 50%. The design and main technical characteristics of the USBE are presented.

  12. Combined Endoscopic and Laparoscopic Management of Postcholecystectomy Mirizzi Syndrome from a Remnant Cystic Duct Stone: Case Report and Review of the Literature

    PubMed Central

    Amin, Arpit; Zhurov, Yuriy; Ibrahim, George; Maffei, Anthony; Giannone, Jonathan; Cerabona, Thomas; Kaul, Ashutosh

    2016-01-01

    Mirizzi syndrome has been defined in the literature as common bile duct obstruction resulting from calculi within Hartmann's pouch or cystic duct. We present a case of a 78-year-old female, who developed postcholecystectomy Mirizzi syndrome from a remnant cystic duct stone. Diagnosis of postcholecystectomy Mirizzi syndrome was made on endoscopic retrograde cholangiography (ERCP) performed postoperatively. The patient was treated with a novel strategy by combining advanced endoscopic and laparoscopic techniques in three stages as follows: Stage 1 (initial presentation): endoscopic sphincterotomy with common bile duct stent placement; Stage 2 (6 weeks after Stage 1): laparoscopic ultrasonography to locate the remnant cystic duct calculi followed by laparoscopic retrieval of the calculi and intracorporeal closure of cystic duct stump; Stage 3 (6 weeks after Stage 2): endoscopic removal of common bile duct stent along with performance of completion endoscopic retrograde cholangiogram. In addition, we have performed an extensive review of the various endoscopic and laparoscopic management techniques described in the literature for the treatment of postcholecystectomy syndrome occurring from retained cystic duct stones. PMID:27047698

  13. [Endoscopic operation in the treatment of congenital duodenal membranous stenosis].

    PubMed

    Kong, Chihuan; Li, Long; Dong, Ning; Li, Xu; Zhang, Yanling

    2015-08-01

    To investigate the safety and efficacy of endoscopic duodenal valvectomy in the treatment of congenital duodenal membranous stenosis. Clinical data of two children with congenital duodenal membranous stenosis undergoing endoscopic duodenal valvectomy in our institute within October 2014 were analyzed retrospectively. This procedure was performed with Microknife XL and CRE balloon catheter through porous channel in the 9 mm flexible endoscope. The first case was a 2-year-old boy who received two endoscopic operations including duodenal diaphragm resection and duodenal dilatation because of incision retraction. The second case was a 19-month-old gril who received once endoscopic duodenal valvectomy. Duodenal obstruction of these two children was relieved after operation. Postoperative x-rays showed no perforation. They could play in the floor 6 hours after operation without any complains, drink water 12 hours, take liquid diets 2 days and half solid food 3 days after operation. During follow-up a month after operation, the body weight gained was 1.5 and 1.0 kg respectively, and the dietary components was significantly improved. Endoscopic duodenal valvectomy is feasible and effective in the treatment of congenital duodenal membranous stenosis.

  14. Epigastric hernia contiguous with the laparoscopic port site after endoscopic robotic total prostatectomy.

    PubMed

    Moriwaki, Yoshihiro; Otani, Jun; Okuda, Junzo; Maemoto, Ryo

    2018-03-23

    Both laparoscopic and endoscopic robotic surgery are widely accepted for many abdominal surgeries. However, the port site for the laparoscope cannot be easily sutured without defect, particularly in the cranial end; this can result in a port-site incisional hernia and trigger the progressive thinning and stretching of the linea alba, leading to epigastric hernia. In the present case, we encountered an epigastric hernia contiguous with an incisional scar at the port site from a previous endoscopic robotic total prostatectomy. Abdominal ultrasound and CT revealed that the width of the linea alba was 30-48 mm. Previous CT images prepared before endoscopic robotic prostatectomy had shown a thinning of the linea alba. We should be aware of the possibility of epigastric hernia after laparoscopic and endoscopic robotic surgery. In laparoscopic and endoscopic robotic surgery for a high-risk patient for epigastric hernia, we should consider additional sutures cranial to the port-site incision to prevent of an epigastric hernia. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  15. Combined Endoscopic and Laparoscopic Management of Postcholecystectomy Mirizzi Syndrome from a Remnant Cystic Duct Stone: Case Report and Review of the Literature.

    PubMed

    Amin, Arpit; Zhurov, Yuriy; Ibrahim, George; Maffei, Anthony; Giannone, Jonathan; Cerabona, Thomas; Kaul, Ashutosh

    2016-01-01

    Mirizzi syndrome has been defined in the literature as common bile duct obstruction resulting from calculi within Hartmann's pouch or cystic duct. We present a case of a 78-year-old female, who developed postcholecystectomy Mirizzi syndrome from a remnant cystic duct stone. Diagnosis of postcholecystectomy Mirizzi syndrome was made on endoscopic retrograde cholangiography (ERCP) performed postoperatively. The patient was treated with a novel strategy by combining advanced endoscopic and laparoscopic techniques in three stages as follows: Stage 1 (initial presentation): endoscopic sphincterotomy with common bile duct stent placement; Stage 2 (6 weeks after Stage 1): laparoscopic ultrasonography to locate the remnant cystic duct calculi followed by laparoscopic retrieval of the calculi and intracorporeal closure of cystic duct stump; Stage 3 (6 weeks after Stage 2): endoscopic removal of common bile duct stent along with performance of completion endoscopic retrograde cholangiogram. In addition, we have performed an extensive review of the various endoscopic and laparoscopic management techniques described in the literature for the treatment of postcholecystectomy syndrome occurring from retained cystic duct stones.

  16. 3-D endoscopic imaging using plenoptic camera

    PubMed Central

    Le, Hanh N. D.; Decker, Ryan; Opferman, Justin; Kim, Peter; Krieger, Axel

    2017-01-01

    Three-dimensional endoscopic imaging using plenoptic technique combined with F-matching algorithm has been pursued in this study. A custom relay optics was designed to integrate a commercial surgical straight endoscope with a plenoptic camera. PMID:29276806

  17. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Endoscopic electrosurgical unit and accessories. (a) Identification. An endoscopic electrosurgical unit and... device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode, flexible snare, electrosurgical alarm system, electrosurgical power supply unit, electrical clamp, self...

  18. Sparse aperture endoscope

    DOEpatents

    Fitch, J.P.

    1999-07-06

    An endoscope is disclosed which reduces the volume needed by the imaging part, maintains resolution of a wide diameter optical system, while increasing tool access, and allows stereographic or interferometric processing for depth and perspective information/visualization. Because the endoscope decreases the volume consumed by imaging optics such allows a larger fraction of the volume to be used for non-imaging tools, which allows smaller incisions in surgical and diagnostic medical applications thus produces less trauma to the patient or allows access to smaller volumes than is possible with larger instruments. The endoscope utilizes fiber optic light pipes in an outer layer for illumination, a multi-pupil imaging system in an inner annulus, and an access channel for other tools in the center. The endoscope is amenable to implementation as a flexible scope, and thus increases it's utility. Because the endoscope uses a multi-aperture pupil, it can also be utilized as an optical array, allowing stereographic and interferometric processing. 7 figs.

  19. Sparse aperture endoscope

    DOEpatents

    Fitch, Joseph P.

    1999-07-06

    An endoscope which reduces the volume needed by the imaging part thereof, maintains resolution of a wide diameter optical system, while increasing tool access, and allows stereographic or interferometric processing for depth and perspective information/visualization. Because the endoscope decreases the volume consumed by imaging optics such allows a larger fraction of the volume to be used for non-imaging tools, which allows smaller incisions in surgical and diagnostic medical applications thus produces less trauma to the patient or allows access to smaller volumes than is possible with larger instruments. The endoscope utilizes fiber optic light pipes in an outer layer for illumination, a multi-pupil imaging system in an inner annulus, and an access channel for other tools in the center. The endoscope is amenable to implementation as a flexible scope, and thus increases the utility thereof. Because the endoscope uses a multi-aperture pupil, it can also be utilized as an optical array, allowing stereographic and interferometric processing.

  20. Per-oral endoscopic myotomy: Major advance in achalasia treatment and in endoscopic surgery

    PubMed Central

    Friedel, David; Modayil, Rani; Stavropoulos, Stavros N

    2014-01-01

    Per-oral endoscopic myotomy (POEM) represents a natural orifice endoscopic surgery (NOTES) approach to laparoscopy Heller myotomy (LHM). POEM is arguably the most successful clinical application of NOTES. The growth of POEM from a single center in 2008 to approximately 60 centers worldwide in 2014 with several thousand procedures having been performed attests to the success of POEM. Initial efficacy, safety and acid reflux data suggest at least equivalence of POEM to LHM, the previous gold standard for achalasia therapy. Adjunctive techniques used in the West include impedance planimetry for real-time intraprocedural luminal assessment and endoscopic suturing for challenging mucosal defect closures during POEM. The impact of POEM extends beyond the realm of esophageal motility disorders as it is rapidly popularizing endoscopic submucosal dissection in the West and spawning offshoots that use the submucosal tunnel technique for a host of new indications ranging from resection of tumors to pyloromyotomy for gastroparesis. PMID:25548473

  1. Endoscopic management of hilar biliary strictures

    PubMed Central

    Singh, Rajiv Ranjan; Singh, Virendra

    2015-01-01

    Hilar biliary strictures are caused by various benign and malignant conditions. It is difficult to differentiate benign and malignant strictures. Postcholecystectomy benign biliary strictures are frequently encountered. Endoscopic management of these strictures is challenging. An endoscopic method has been advocated that involves placement of increasing number of stents at regular intervals to resolve the stricture. Malignant hilar strictures are mostly unresectable at the time of diagnosis and only palliation is possible.Endoscopic palliation is preferred over surgery or radiological intervention. Magnetic resonance cholangiopancreaticography is quite important in the management of these strictures. Metal stents are superior to plastic stents. The opinion is divided over the issue of unilateral or bilateral stenting.Minimal contrast or no contrast technique has been advocated during endoscopic retrograde cholangiopancreatography of these patients. The role of intraluminal brachytherapy, intraductal ablation devices, photodynamic therapy, and endoscopic ultrasound still remains to be defined. PMID:26191345

  2. Long-term outcome of peroral endoscopic myotomy for achalasia treatment in a 9-year-old female patient.

    PubMed

    Yamashita, Kanefumi; Shiwaku, Hironari; Hirose, Ryuichiro; Kai, Hiroki; Nakashima, Ryo; Kato, Daisuke; Beppu, Richiko; Takeno, Shinsuke; Sasaki, Takamitsu; Nimura, Satoshi; Iwasaki, Akinori; Inoue, Haruhiro; Yamashita, Yuichi

    2016-11-01

    Achalasia is a primary motility disorder with incomplete lower esophageal sphincter relaxation; it has an annual incidence of 0.11 cases per 100 000 children. Peroral endoscopic myotomy (POEM) is a new endoscopic treatment method for achalasia. Reports about POEM in pediatric patients are rare. We herein report the case of a 9-year-old female patient with achalasia who underwent POEM. The patient underwent endoscopic balloon dilatation because medication was not effective at a previous hospital; however, endoscopic balloon dilatation was not effective either. She then underwent successful POEM upon admission at our hospital. The patient was symptom-free at 2 years postoperatively with no signs of esophagitis in the absence of proton-pump inhibitor therapy. © 2016 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  3. Endoscopes with latest technology and concept.

    PubMed

    Gotoh

    2003-09-01

    Endoscopic imaging systems that perform as the "eye" of the operator during endoscopic surgical procedures have developed rapidly due to various technological developments. In addition, since the most recent turn of the century robotic surgery has increased its scope through the utilization of systems such as Intuitive Surgical's da Vinci System. To optimize the imaging required for precise robotic surgery, a unique endoscope has been developed, consisting of both a two dimensional (2D) image optical system for wider observation of the entire surgical field, and a three dimensional (3D) image optical system for observation of the more precise details at the operative site. Additionally, a "near infrared radiation" endoscopic system is under development to detect the sentinel lymph node more readily. Such progress in the area of endoscopic imaging is expected to enhance the surgical procedure from both the patient's and the surgeon's point of view.

  4. Ultrasound-assisted endoscopic partial plantar fascia release.

    PubMed

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.

  5. Ultrasound-Assisted Endoscopic Partial Plantar Fascia Release

    PubMed Central

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure. PMID:24265989

  6. Endoscopic submucosal dissection using flexknife.

    PubMed

    Kodashima, Shinya; Fujishiro, Mitsuhiro; Yahagi, Naohisa; Kakushima, Naomi; Omata, Masao

    2006-01-01

    Although the standard treatment for early-stage gastrointestinal tumors is still surgical resection, endoscopic resection has been accepted for some of these lesions, especially in Japan. However, the indication was limited until recently to achieve en bloc resection and prevent local recurrence. To overcome the disadvantage of endoscopic resection with conventional endoscopic mucosal resection (EMR), several investigators, including us, have developed a new endoscopic resection technique: endoscopic submucosal dissection (ESD). ESD is a remarkable technique that enables to remove the lesions en bloc regardless of size, shape, coexisting ulcer, and location. Nowadays, several knives are available for ESD, such as the needle knife, insulation-tipped (IT) knife, Hookknife, triangle-tipped (TT) knife, and Flexknife. Each of them has some merits and demerits, and the ways to use the knives are different. We summarize here how to use the Flexknife, which we made ourselves in cooperation with the Olympus Company, and how we use the technique in our hospital.

  7. Recent Evolution of Endoscopic Endonasal Surgery for Treatment of Pituitary Adenomas

    PubMed Central

    NISHIOKA, Hiroshi

    2017-01-01

    For the treatment of pituitary tumors, microscopic transsphenoidal surgery has been considered the “gold standard” since the late 1960s. Over the last two decades, however, a worldwide shift towards endoscopic endonasal surgery is in progress for many reasons. These include a wide panoramic view, improved illumination, an ability to look around anatomical corners using angled tip and, in addition, application to the extended approaches for parasellar tumors. Both endoscopic and microscopic approaches appear equally effective for nonfunctioning adenomas without significant suprasellar or lateral extensions, whereas the endoscopic approach may improve outcomes associated with the extent of resection and postoperative complications for larger tumors. Despite many theoretical benefits in the endoscopic surgery, remission rates of functioning adenomas do not substantially differ between the approaches in experienced hands. The endoscopic approach is a valid alternative to the microscopic approach for adenomas. The benefits will be more appreciated in the extended surgery for parasellar tumors. PMID:28239067

  8. Direct cost comparison of totally endoscopic versus open ear surgery.

    PubMed

    Patel, N; Mohammadi, A; Jufas, N

    2018-02-01

    Totally endoscopic ear surgery is a relatively new method for managing chronic ear disease. This study aimed to test the null hypothesis that open and endoscopic approaches have similar direct costs for the management of attic cholesteatoma, from an Australian private hospital setting. A retrospective direct cost comparison of totally endoscopic ear surgery and traditional canal wall up mastoidectomy for the management of attic cholesteatoma in a private tertiary setting was undertaken. Indirect and future costs were excluded. A direct cost comparison of anaesthetic setup and resources, operative setup and resources, and surgical time was performed between the two techniques. Totally endoscopic ear surgery has a mean direct cost reduction of AUD$2978.89 per operation from the hospital perspective, when compared to canal wall up mastoidectomy. Totally endoscopic ear surgery is more cost-effective, from an Australian private hospital perspective, than canal wall up mastoidectomy for attic cholesteatoma.

  9. Endoscopic Removal of a Bullet That Migrated to the Third Ventricle Causing Hydrocephalus.

    PubMed

    Aydoseli, Aydın; Unal, Tugrul Cem; Aras, Yavuz; Sabanci, Pulat Akın; Altunrende, Emre; Izgi, Nail

    2017-09-01

    Hydrocephalus caused by an intraventricular bullet is a rare event. We report a case of endoscopic removal of an intraventricular bullet. A 66-year-old man was admitted with a gunshot wound to the head after a suicide attempt. The bullet migrated from the frontal parenchyma to the third ventricle day 4 of admission. On day 21 of admission, the patient developed hydrocephalus with obstruction of the cerebral aqueduct. The bullet was accessed through an endoscopic third ventriculostomy and removed using an endoscope. Hydrocephalus may develop in patients with intraventricular foreign objects. When such objects must be removed, the endoscopic approach is a safe, efficient, and minimally invasive procedure. To our knowledge, this is the first case in the literature of foreign object removal from the ventricle via a transcortical endoscopic approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. What is the best management strategy for high grade dysplasia in Barrett's oesophagus? A cost effectiveness analysis.

    PubMed

    Shaheen, N J; Inadomi, J M; Overholt, B F; Sharma, P

    2004-12-01

    Multiple treatment strategies for subjects with high grade dysplasia (HGD) in Barrett's oesophagus (BO) have been suggested. However, it is unclear which of these strategies provides the greatest life expectancy, and the costs associated with the management strategies are unknown. To compare the efficacy and cost effectiveness of competing management strategies for BO with HGD. We created a decision analysis model in Data 4.0 to assess possible treatment strategies for BO with HGD. The strategies included: (1) no preventative strategy, (2) elective surgical oesophagectomy, (3) endoscopic ablation, and (4) surveillance endoscopy. The base case was a healthy 50 year old White male with an initial diagnosis of BO with HGD. The model allowed for complications of surgery, including death. Ablative therapy could cause stricture or perforation. Pathological misinterpretation was allowed, and modelled after reported rates. Estimates were derived from the literature for the rate of progression of HGD to cancer and for complication rates for the various treatment modalities. The endoscopic ablation arm was modelled as photodynamic therapy. Sensitivity analyses were performed over a wide range of cancer incidences, complication rates, and procedure costs. Endoscopic ablation was the most effective strategy, yielding 15.5 discounted quality adjusted life years (dQALY), compared with 15.0 for endoscopic surveillance and 14.9 for oesophagectomy. No preventative strategy was the most inexpensive option, yielding an average cost per quality adjusted life year of US dollars 54 (44) per dQALY, but resulted in high rates of cancer. Endoscopic surveillance dominated oesophagectomy, being both less costly and more effective. The condition of extended dominance occurred when comparing endoscopic ablation to endoscopic surveillance because, although the total costs of ablation were greater than those of surveillance, it was less expensive to buy an additional life year using endoscopic ablation than endoscopic surveillance. The incremental cost effectiveness ratio when moving from no therapy to ablative therapy was a reasonable US dollars 25 621/dQALY (21 009/dQALY). Sensitivity analysis demonstrated that when yearly rates of progression to cancer from HGD exceeded 30%, oesophagectomy became the most cost effective option. A strategy of endoscopic ablation provided the longest quality adjusted life expectancy for BO with HGD. Although endoscopic surveillance was less expensive than endoscopic ablation, it was associated with shorter survival. Optimal utilisation of healthcare resources may be achieved with endoscopic ablative therapy for BO with HGD.

  11. Endoscopic therapy of posttransplant biliary stenoses after right-sided adult living donor liver transplantation.

    PubMed

    Zoepf, Thomas; Maldonado-Lopez, Evelyn J; Hilgard, Philip; Schlaak, Joerg; Malago, Massimo; Broelsch, Christoph E; Treichel, Ulrich; Gerken, Guido

    2005-11-01

    Endoscopic treatment of biliary strictures after liver transplantation is a therapeutic challenge. In particular, outcomes of endoscopic therapy of biliary complications in the case of duct-to-duct anastomosis after living related liver transplantation are limited. The aim of this study was to evaluate the feasibility and success of an endoscopic treatment approach to posttransplant biliary strictures (PTBS) after right-sided living donor liver transplantation (RLDLT) with duct-to-duct anastomosis. Ninety patients who received adult-to-adult RLDLT in our center were screened retrospectively with respect to endoscopic treatment of PTBS. Therapy was judged as successful when cholestasis parameters returned to normal and bile duct narrowing was reduced significantly after the completion of therapy. Forty of 90 RLDLT patients received duct-to-duct anastomosis, 12 (30%) showed PTBS. Seven of 12 patients were treated successfully by endoscopy; the remaining 5 patients were treated primarily by surgery. Most patients were treated by balloon dilatation followed by insertion of endoprostheses. A median of 2.5 dilatation sessions were necessary and the median treatment duration was 8 months. One patient developed endoscopy-treatable recurrent stenosis, no surgical intervention was necessary. Mild pancreatitis occurred in 7.9% and cholangitis in 5.3% of the procedures. One minor bleeding episode occurred during sphincterotomy. Bleeding was managed endoscopically. Endoscopic therapy of adult-to-adult right living related liver transplantation with duct-to-duct anastomosis is feasible and frequently is successful. The duct-to-duct anastomosis offers the possibility of endoscopic treatment. Endoscopic treatment of posttransplant biliary strictures is safe, with a low specific complication rate.

  12. Design of a modified endoscope illuminator for spectral imaging of colorectal tissues

    NASA Astrophysics Data System (ADS)

    Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.

    2017-02-01

    The gold standard for locating colonic polyps is a white light endoscope in a colonoscopy, however, polyps smaller than 5 mm can be easily missed. Modified procedures such as narrow band imaging have shown only marginal increases in detection rates. Spectral imaging is a potential solution to improve the sensitivity and specificity of colonoscopies by providing the ability to distinguish molecular fluorescence differences in tissues. The goal of this work is to implement a spectral endoscopic light source to acquire spectral image data of colorectal tissues. A beta-version endoscope light source was developed, by retrofitting a white light endoscope light source (Olympus, CLK-4) with 16 narrow band LEDs. This redesigned, beta-prototype uses high-power LEDs with a minimum output of 500 mW to provide sufficient spectral output (0.5 mW) through the endoscope. A mounting apparatus was designed to provide sufficient heat dissipation. Here, we report recent results of our tests to characterize the intensity output through the light source and endoscope to determine the flat spectral output for imaging and intensity losses through the endoscope. We also report preliminary spectral imaging data from transverse pig colon that demonstrates the ability to result in working practical spectral data. Preliminary results of this revised prototype spectral endoscope system demonstrate that there is sufficient power to allow the imaging process to continue and potentially determine spectral differences in cancerous and normal tissue from imaging ex vivo pairs. Future work will focus on building a spectral library for the colorectal region and refining the user interface the system for in vivo use.

  13. Management of pancreatic fluid collections: A comprehensive review of the literature

    PubMed Central

    Tyberg, Amy; Karia, Kunal; Gabr, Moamen; Desai, Amit; Doshi, Rushabh; Gaidhane, Monica; Sharaiha, Reem Z; Kahaleh, Michel

    2016-01-01

    Pancreatic fluid collections (PFCs) are a frequent complication of pancreatitis. It is important to classify PFCs to guide management. The revised Atlanta criteria classifies PFCs as acute or chronic, with chronic fluid collections subdivided into pseudocysts and walled-off pancreatic necrosis (WOPN). Establishing adequate nutritional support is an essential step in the management of PFCs. Early attempts at oral feeding can be trialed in patients with mild pancreatitis. Enteral feeding should be implemented in patients with moderate to severe pancreatitis. Jejunal feeding remains the preferred route of enteral nutrition. Symptomatic PFCs require drainage; options include surgical, percutaneous, or endoscopic approaches. With the advent of newer and more advanced endoscopic tools and expertise, and an associated reduction in health care costs, minimally invasive endoscopic drainage has become the preferable approach. An endoscopic ultrasonography-guided approach using a seldinger technique is the preferred endoscopic approach. Both plastic stents and metal stents are efficacious and safe; however, metal stents may offer an advantage, especially in infected pseudocysts and in WOPN. Direct endoscopic necrosectomy is often required in WOPN. Lumen apposing metal stents that allow for direct endoscopic necrosectomy and debridement through the stent lumen are preferred in these patients. Endoscopic retrograde cholangio pancreatography with pancreatic duct (PD) exploration should be performed concurrent to PFC drainage. PD disruption is associated with an increased severity of pancreatitis, an increased risk of recurrent attacks of pancreatitis and long-term complications, and a decreased rate of PFC resolution after drainage. Any pancreatic ductal disruption should be bridged with endoscopic stenting. PMID:26900288

  14. Outcomes of endonasal endoscopic dacryocystorhinostomy after maxillectomy in patients with paranasal sinus and skull base tumors.

    PubMed

    Abu-Ghanem, Sara; Ben-Cnaan, Ran; Leibovitch, Igal; Horowitz, Gilad; Fishman, Gadi; Fliss, Dan M; Abergel, Avraham

    2014-06-01

    Maxillectomy followed by radiotherapy and/or chemotherapy can result in lacrimal blockage and the need for subsequent dacryocystorhinostomy (DCR). Endonasal endoscopic DCR, as opposed to external DCR, allows better accuracy and leaves no scar. To date no report was published regarding the results of endoscopic DCR in these patients. The current study presents a retrospective review of all patients with paranasal and skull base tumors who developed nasolacrimal duct blockage after ablative maxillectomy with or without radiotherapy and/or chemotherapy and underwent endonasal endoscopic DCR between January 2006 and October 2012 in a tertiary reference medical center. According to our results, ten patients underwent 11 subsequent endonasal endoscopic DCR. There were 6 men and 4 women with a median age of 55 years (range, 19-81 years); four suffered from benign tumors and six had malignant tumors. All underwent maxillectomy. Six received high-dose radiotherapy. Time interval between primary ablative surgery and endonasal endoscopic DCR was 18 months (range, 7-118 months). Silicone stents were removed after median period of 11 weeks (range, 1-57 weeks). Nine out of ten patients experienced symptomatic improvement following one endonasal endoscopic DCR. One patient had recurrent epiphora and underwent a successful endonasal endoscopic revision DCR. In conclusion, endonasal endoscopic DCR in patients with paranasal and skull base tumors, who previously underwent maxillectomy, is generally successful and not associated with a high rate of complications or failure. Moreover, our findings may suggest that silicone stents can be removed shortly after the operation with high success rate.

  15. Comparison of endoscopic and microscopic trans-sphenoidal pituitary surgery: early results in a single centre.

    PubMed

    Razak, Adam A; Horridge, Michelle; Connolly, Daniel J; Warren, Daniel J; Mirza, Showkat; Muraleedharan, Vakkat; Sinha, Saurabh

    2013-02-01

    Pituitary surgery has seen a recent shift from a microscopic to an endoscopic trans-sphenoidal approach. We present our early experience with endoscopic surgery and compare the outcome with our recent microscopic experience. From January 2008 until present time, 80 consecutive patients underwent trans-sphenoidal pituitary surgery in our institution. Until September 2009, all patients had a microscopic trans-septal approach. After this time, the patients underwent endoscopic trans-sphenoidal surgery. All patients underwent pre- and post-operative MRI and full endocrinological evaluation. Data was collected prospectively including tumour volume, endocrine function, visual function, length of stay and complications. There were 40 patients in each group. In the microscopic group, there were 26 non-functioning tumours and 14 functioning tumours. In the endoscopic group, there were 24 non-functioning and 16 functioning tumours. There were significantly better results in terms of tumour resection (p = 0.002) and remission (p = 0.018) in the endoscopic group. In this group there was also a lower incidence of CSF leaks and a shorter length of stay for secreting tumours (p = 0.005). 1 patient in the endoscopic group died at day 43 post-operatively, having initially presented in a poor clinical state with pituitary apoplexy. Microscopic trans-sphenoidal surgery remains the benchmark for future surgical techniques. Our early results suggest that endoscopic trans-sphenoidal surgery provides favourable results in both tumour resection and control of secreting tumours in comparison with microscopic surgery. Further longer-term evaluation is required to ensure the outcome of endoscopic surgery.

  16. Elimination of high titre HIV from fibreoptic endoscopes.

    PubMed Central

    Hanson, P J; Gor, D; Jeffries, D J; Collins, J V

    1990-01-01

    Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the kinetics of elimination of HIV from endoscope surfaces, we artificially contaminated the suction-biopsy channels of five Olympus GIF XQ20 endoscopes with high titre HIV in serum. The air and water channels of two instruments were similarly contaminated. Contamination was measured by irrigating channels with viral culture medium and collecting 3 ml at the distal end for antigen immunoassay. Endoscopes were then cleaned manually in neutral detergent according to the manufacturer's recommendations and disinfected in 2% alkaline glutaraldehyde (Cidex, Surgikos) for two, four, and ten minutes. Contamination with HIV antigens was measured before and after cleaning and after each period of disinfection. Initial contamination comprised 4.8 x 10(4) to 3.5 x 10(6) pg HIV antigen/ml. Cleaning in detergent achieved a reduction to 165 pg/ml (99.93%) on one endoscope and to undetectable levels (100%) on four. After two minutes in alkaline glutaraldehyde all samples were negative and remained negative after the longer disinfection times. Air and water channels, where contaminated, were tested after 10 minutes' disinfection and were negative. These findings underline the importance of cleaning in removing HIV from endoscope and indicate that the use of dedicated equipment and long disinfection times are unnecessary. PMID:2379868

  17. Successful Endoscopic Hemostasis Is a Protective Factor for Rebleeding and Mortality in Patients with Nonvariceal Upper Gastrointestinal Bleeding.

    PubMed

    Han, Yong Jae; Cha, Jae Myung; Park, Jae Hyun; Jeon, Jung Won; Shin, Hyun Phil; Joo, Kwang Ro; Lee, Joung Il

    2016-07-01

    Rebleeding and mortality rates remain high in patients with nonvariceal upper gastrointestinal bleeding. To identify clinical and endoscopic risk factors for rebleeding and mortality in patients with nonvariceal upper gastrointestinal bleeding. This study was performed in patients with nonvariceal upper gastrointestinal bleeding who underwent upper endoscopic procedures between July 2006 and February 2013. Clinical and endoscopic characteristics were compared among patients with and without rebleeding and mortality. Logistic regression analysis was performed to determine independent risk factors for rebleeding and mortality. After excluding 64 patients, data for 689 patients with nonvariceal upper gastrointestinal bleeding were analyzed. Peptic ulcer (62.6 %) was by far the most common source of bleeding. Endoscopic intervention was performed within 24 h in 99.0 % of patients, and successful endoscopic hemostasis was possible in 80.7 % of patients. The 30-day rebleeding rate was 13.1 % (n = 93). Unsuccessful endoscopic hemostasis was found to be the only independent risk factor for rebleeding (odds ratio 79.6; 95 % confidence interval 37.8-167.6; p = 0.000). The overall 30-day mortality rate was 3.2 % (n = 23). Unsuccessful endoscopic hemostasis (odds ratio 4.9; 95 % confidence interval 1.7-13.9; p = 0.003) was also associated with increased 30-day mortality in patients with nonvariceal upper gastrointestinal bleeding. Successful endoscopic hemostasis is an independent protective factor for both rebleeding and mortality in patients with nonvariceal upper gastrointestinal bleeding.

  18. Early experiences of endoscopic procedures in general surgery assisted by a computer-enhanced surgical system.

    PubMed

    Hashizume, M; Shimada, M; Tomikawa, M; Ikeda, Y; Takahashi, I; Abe, R; Koga, F; Gotoh, N; Konishi, K; Maehara, S; Sugimachi, K

    2002-08-01

    We performed a variety of complete total endoscopic general surgical procedures, including colon resection, distal gastrectomy, and splenectomy, successfully with the assistance of the da Vinci computer-enhanced surgical system. The robotic system allowed us to manipulate the endoscopic instruments as effectively as during open surgery. It enhanced visualization of both the operative field and precision of the necessary techniques, as well as being less stressful for the endoscopic operating team. This technological innovation can therefore help surgeons overcome many of the difficulties associated with the endoscopic approach and thus has the potential to enable more precise, safer, and more minimally invasive surgery in the future.

  19. Advanced endoscopic imaging to improve adenoma detection

    PubMed Central

    Neumann, Helmut; Nägel, Andreas; Buda, Andrea

    2015-01-01

    Advanced endoscopic imaging is revolutionizing our way on how to diagnose and treat colorectal lesions. Within recent years a variety of modern endoscopic imaging techniques was introduced to improve adenoma detection rates. Those include high-definition imaging, dye-less chromoendoscopy techniques and novel, highly flexible endoscopes, some of them equipped with balloons or multiple lenses in order to improve adenoma detection rates. In this review we will focus on the newest developments in the field of colonoscopic imaging to improve adenoma detection rates. Described techniques include high-definition imaging, optical chromoendoscopy techniques, virtual chromoendoscopy techniques, the Third Eye Retroscope and other retroviewing devices, the G-EYE endoscope and the Full Spectrum Endoscopy-system. PMID:25789092

  20. Pneumoretroperitoneum and Sepsis After Transanal Endoscopic Resection of a Rectal Lateral Spreading Tumor

    PubMed Central

    Coura, Marcelo de Melo Andrade; de Almeida, Romulo Medeiros; Moreira, Natascha Mourão; de Sousa, João Batista; de Oliveira, Paulo Gonçalves

    2017-01-01

    Transanal endoscopic microsurgery is considered a safe, appropriate, and minimally invasive approach, and complications after endoscopic microsurgery are rare. We report a case of sepsis and pneumoretroperitoneum after resection of a rectal lateral spreading tumor. The patient presented with rectal mucous discharge. Colonoscopy revealed a rectal lateral spreading tumor. The patient underwent an endoscopic transanal resection of the lesion. He presented with sepsis of the abdominal focus, and imaging tests revealed pneumoretroperitoneum. A new surgical intervention was performed with a loop colostomy. Despite the existence of other reports on pneumoretroperitoneum after transanal endoscopic microsurgery, what draws attention to this case is the association with sepsis. PMID:28761873

  1. Design of illumination system in ring field capsule endoscope

    NASA Astrophysics Data System (ADS)

    Jeng, Wei-De; Mang, Ou-Yang; Chen, Yu-Ta; Wu, Ying-Yi

    2011-03-01

    This paper is researching about the illumination system in ring field capsule endoscope. It is difficult to obtain the uniform illumination on the observed object because the light intensity of LED will be changed along its angular displacement and same as luminous intensity distribution curve. So we use the optical design software which is Advanced Systems Analysis Program (ASAP) to build a photometric model for the optimal design of LED illumination system in ring field capsule endoscope. In this paper, the optimal design of illumination uniformity in the ring field capsule endoscope is from origin 0.128 up to optimum 0.603 and it would advance the image quality of ring field capsule endoscope greatly.

  2. Endoscopic endonasal double flap technique for reconstruction of large anterior skull base defects: technical note.

    PubMed

    Dolci, Ricardo Landini Lutaif; Todeschini, Alexandre Bossi; Santos, Américo Rubens Leite Dos; Lazarini, Paulo Roberto

    2018-04-19

    One of the main concerns in endoscopic endonasal approaches to the skull base has been the high incidence and morbidity associated with cerebrospinal fluid leaks. The introduction and routine use of vascularized flaps allowed a marked decrease in this complication followed by a great expansion in the indications and techniques used in endoscopic endonasal approaches, extending to defects from huge tumours and previously inaccessible areas of the skull base. Describe the technique of performing endoscopic double flap multi-layered reconstruction of the anterior skull base without craniotomy. Step by step description of the endoscopic double flap technique (nasoseptal and pericranial vascularized flaps and fascia lata free graft) as used and illustrated in two patients with an olfactory groove meningioma who underwent an endoscopic approach. Both patients achieved a gross total resection: subsequent reconstruction of the anterior skull base was performed with the nasoseptal and pericranial flaps onlay and a fascia lata free graft inlay. Both patients showed an excellent recovery, no signs of cerebrospinal fluid leak, meningitis, flap necrosis, chronic meningeal or sinonasal inflammation or cerebral herniation having developed. This endoscopic double flap technique we have described is a viable, versatile and safe option for anterior skull base reconstructions, decreasing the incidence of complications in endoscopic endonasal approaches. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  3. Duodenal endoscopic findings and histopathologic confirmation of intestinal lymphangiectasia in dogs.

    PubMed

    Larson, R N; Ginn, J A; Bell, C M; Davis, M J; Foy, D S

    2012-01-01

    The diagnosis of intestinal lymphangiectasia (IL) has been associated with characteristic duodenal mucosal changes. However, the sensitivity and specificity of the endoscopic duodenal mucosal appearance for the diagnosis of IL are not reported. To evaluate the utility of endoscopic images of the duodenum for diagnosis of IL. Endoscopic appearance of the duodenal mucosal might predict histopathologic diagnosis of IL with a high degree of sensitivity and specificity. 51 dogs that underwent upper gastrointestinal (GI) endoscopy and endoscopic biopsies. Retrospective review of images acquired during endoscopy. Dogs were included if adequate biopsies were obtained during upper GI endoscopy and digital images were saved during the procedure. Images were assessed for the presence and severity of IL. Using histopathology as the gold standard, the sensitivity and specificity of endoscopy for diagnosing IL were calculated. Intestinal lymphangiectasia (IL) was diagnosed in 25/51 dogs. Gross endoscopic appearance of the duodenal mucosa had a sensitivity and specificity (95% confidence interval) of 68% (46%, 84%) and 42% (24%, 63%), respectively for diagnosis of IL. Endoscopic images in cases with lymphopenia, hypocholesterolemia, and hypoalbuminemia had a sensitivity of 80%. Endoscopic duodenal mucosa appearance alone lacks specificity and has only a moderate sensitivity for diagnosis of IL. Evaluation of biomarkers associated with PLE improved the sensitivity; however, poor specificity for diagnosis of IL supports the need for histopathologic confirmation. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  4. The effect of ursodeoxycholic acid in liver functional restoration of patients with obstructive jaundice after endoscopic treatment: a prospective, randomized, and controlled study.

    PubMed

    Fekaj, Enver; Gjata, Arben; Maxhuni, Mehmet

    2013-09-22

    In patients with obstructive jaundice, multi-organ dysfunction may develop. This trial is a prospective, open-label, randomized, and controlled study with the objective to evaluate the effect of ursodeoxycholic acid in liver functional restoration in patients with obstructive jaundice after endoscopic treatment. The aim of this study is to evaluate the effect of ursodeoxycholic acid in liver functional restoration of patients with obstructive jaundice after endoscopic treatment. The hypothesis of this trial is that patients with obstructive jaundice, in which will be administered UDCA, in the early phase after endoscopic intervention will have better and faster functional restoration of the liver than patients in the control group.Patients with obstructive jaundice, randomly, will be divided into two groups: (A) test group in which will be administered ursodeoxycholic acid twenty-four hours after endoscopic procedure and will last fourteen days, and (B) control group.Serum-testing will include determination of bilirubin, alanine transaminase, aspartate transaminase, gama-glutamil transpeptidase, alkaline phosphatase, albumin, and cholesterol levels. These parameters will be determined one day prior endoscopic procedure, and on the third, fifth, seventh, tenth, twelfth and fourteenth days after endoscopic intervention. This trial is a prospective, open-label, randomized, and controlled study to asses the effect of ursodeoxycholic acid in liver functional restoration of patients with obstructive jaundice in the early phase after endoscopic treatment.

  5. Endoscopic therapy for weight loss: Gastroplasty, duodenal sleeves, intragastric balloons, and aspiration

    PubMed Central

    Kumar, Nitin

    2015-01-01

    A new paradigm in the treatment of obesity and metabolic disease is developing. The global obesity epidemic continues to expand despite the availability of diet and lifestyle counseling, pharmacologic therapy, and weight loss surgery. Endoscopic procedures have the potential to bridge the gap between medical therapy and surgery. Current primary endoscopic bariatric therapies can be classified as restrictive, bypass, space-occupying, or aspiration therapy. Restrictive procedures include the USGI Primary Obesity Surgery Endolumenal procedure, endoscopic sleeve gastroplasty using Apollo OverStitch, TransOral GAstroplasty, gastric volume reduction using the ACE stapler, and insertion of the TERIS restrictive device. Intestinal bypass has been reported using the EndoBarrier duodenal-jejunal bypass liner. A number of space-occupying devices have been studied or are in use, including intragastric balloons (Orbera, Reshape Duo, Heliosphere BAG, Obalon), Transpyloric Shuttle, and SatiSphere. The AspireAssist aspiration system has demonstrated efficacy. Finally, endoscopic revision of gastric bypass to address weight regain has been studied using Apollo OverStitch, the USGI Incisionless Operating Platform Revision Obesity Surgery Endolumenal procedure, Stomaphyx, and endoscopic sclerotherapy. Endoscopic therapies for weight loss are potentially reversible, repeatable, less invasive, and lower cost than various medical and surgical alternatives. Given the variety of devices under development, in clinical trials, and currently in use, patients will have multiple endoscopic options with greater efficacy than medical therapy, and with lower invasiveness and greater accessibility than surgery. PMID:26240686

  6. Reliability of symptoms and endoscopic findings for diagnosis of esophageal eosinophilia in a Japanese population.

    PubMed

    Shimura, Shino; Ishimura, Norihisa; Tanimura, Takashi; Yuki, Takafumi; Miyake, Tatsuya; Kushiyama, Yoshinori; Sato, Shuichi; Fujishiro, Hirofumi; Ishihara, Shunji; Komatsu, Taisuke; Kaneto, Eiji; Izumi, Akio; Ishikawa, Noriyoshi; Maruyama, Riruke; Kinoshita, Yoshikazu

    2014-01-01

    The clinical characteristics of esophageal eosinophilia (EE), which is essential for diagnosis of eosinophilic esophagitis (EoE), have not been fully clarified in a Japanese population. The aim of this study was to analyze the reliability of symptoms and endoscopic findings for diagnosing EE in Japanese individuals. We prospectively enrolled subjects who complained of esophageal symptoms suggesting EoE and/or those with endoscopic findings of suspected EoE at the outpatient clinics of 12 hospitals. Diagnostic utility was compared between the EE and non-EE groups using logistic regression analysis. A total of 349 patients, including 319 with symptoms and 30 with no symptoms but endoscopic findings suggesting EoE were enrolled. Of those with symptoms, 8 (2.5%) had EE, and 3 were finally diagnosed with EoE. Of those without symptoms but endoscopic findings, 4 had EE. Among 8 symptomatic patients, 7 had abnormal endoscopic findings suspicious of EoE. Although dysphagia was a major symptom in EE, none of the presenting symptoms was useful for diagnosis of EE. Among the endoscopic findings, linear furrow was the most reliable (OR = 41.583). EE is uncommon among patients with esophageal symptoms in Japanese individuals. The most useful endoscopic finding for diagnosis of EE was linear furrow, whereas subjective symptoms were not supportive. © 2014 S. Karger AG, Basel.

  7. Endoscopic therapy for weight loss: Gastroplasty, duodenal sleeves, intragastric balloons, and aspiration.

    PubMed

    Kumar, Nitin

    2015-07-25

    A new paradigm in the treatment of obesity and metabolic disease is developing. The global obesity epidemic continues to expand despite the availability of diet and lifestyle counseling, pharmacologic therapy, and weight loss surgery. Endoscopic procedures have the potential to bridge the gap between medical therapy and surgery. Current primary endoscopic bariatric therapies can be classified as restrictive, bypass, space-occupying, or aspiration therapy. Restrictive procedures include the USGI Primary Obesity Surgery Endolumenal procedure, endoscopic sleeve gastroplasty using Apollo OverStitch, TransOral GAstroplasty, gastric volume reduction using the ACE stapler, and insertion of the TERIS restrictive device. Intestinal bypass has been reported using the EndoBarrier duodenal-jejunal bypass liner. A number of space-occupying devices have been studied or are in use, including intragastric balloons (Orbera, Reshape Duo, Heliosphere BAG, Obalon), Transpyloric Shuttle, and SatiSphere. The AspireAssist aspiration system has demonstrated efficacy. Finally, endoscopic revision of gastric bypass to address weight regain has been studied using Apollo OverStitch, the USGI Incisionless Operating Platform Revision Obesity Surgery Endolumenal procedure, Stomaphyx, and endoscopic sclerotherapy. Endoscopic therapies for weight loss are potentially reversible, repeatable, less invasive, and lower cost than various medical and surgical alternatives. Given the variety of devices under development, in clinical trials, and currently in use, patients will have multiple endoscopic options with greater efficacy than medical therapy, and with lower invasiveness and greater accessibility than surgery.

  8. Adaptive marker-free registration using a multiple point strategy for real-time and robust endoscope electromagnetic navigation.

    PubMed

    Luo, Xiongbiao; Wan, Ying; He, Xiangjian; Mori, Kensaku

    2015-02-01

    Registration of pre-clinical images to physical space is indispensable for computer-assisted endoscopic interventions in operating rooms. Electromagnetically navigated endoscopic interventions are increasingly performed at current diagnoses and treatments. Such interventions use an electromagnetic tracker with a miniature sensor that is usually attached at an endoscope distal tip to real time track endoscope movements in a pre-clinical image space. Spatial alignment between the electromagnetic tracker (or sensor) and pre-clinical images must be performed to navigate the endoscope to target regions. This paper proposes an adaptive marker-free registration method that uses a multiple point selection strategy. This method seeks to address an assumption that the endoscope is operated along the centerline of an intraluminal organ which is easily violated during interventions. We introduce an adaptive strategy that generates multiple points in terms of sensor measurements and endoscope tip center calibration. From these generated points, we adaptively choose the optimal point, which is the closest to its assigned the centerline of the hollow organ, to perform registration. The experimental results demonstrate that our proposed adaptive strategy significantly reduced the target registration error from 5.32 to 2.59 mm in static phantoms validation, as well as from at least 7.58 mm to 4.71 mm in dynamic phantom validation compared to current available methods. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. Successes rate of endoscopic dacryocystorhinostomy at KMC.

    PubMed

    Shrestha, S; Kafle, P K; Pokhrel, S; Maharjan, M; Toran, K C

    2010-01-01

    Nasolacrimal duct obstruction is a common problem which can be corrected by dacryocystorhinostomy (DCR). The gold standard treatment for this is DCR operation through an external approach. Development of endoscopic sinus surgery and endoscopic DCR performed through intranasal route is a major recent development in this field. The aim of this study is to find out the success rate of endoscopic dacryocystorhinostomy without silicon stent intubation within the period of six month following surgery. A prospective study was done on 26 patients with obstruction of the nasolacrimal duct referred from eye out-patient department to ENT OPD during one year period from 2008 to 2009. All the cases had undergone endoscopic DCR operation which was regularly followed up for a period of six months. Postoperative patency of ostium was checked by sac syringing and endoscopic visualisation of ostium in the nasal cavity. The success of surgery was categorised as: complete cure, partial cure and no improvement depending upon symptomatic relief and clinical examination such as sac syringing and endoscopic examination following surgery. In six months' follow-up, 22 (84.5%) out of 26 patients had achieved the complete cure and 4 patients (15.5%) continued to have persistent epiphora. Endoscopic DCR is a beneficial procedure for nasolacrimal duct obstruction with no external scar on face and less bleeding. The success rate is as good as external DCR.

  10. Laser scanning endoscope for diagnostic medicine

    NASA Astrophysics Data System (ADS)

    Ouimette, Donald R.; Nudelman, Sol; Spackman, Thomas; Zaccheo, Scott

    1990-07-01

    A new type of endoscope is being developed which utilizes an optical raster scanning system for imaging through an endoscope. The optical raster scanner utilizes a high speed, multifaceted, rotating polygon mirror system for horizontal deflection, and a slower speed galvanometer driven mirror as the vertical deflection system. When used in combination, the optical raster scanner traces out a raster similar to an electron beam raster used in television systems. This flying spot of light can then be detected by various types of photosensitive detectors to generate a video image of the surface or scene being illuminated by the scanning beam. The optical raster scanner has been coupled to an endoscope. The raster is projected down the endoscope, thereby illuminating the object to be imaged at the distal end of the endoscope. Elemental photodetectors are placed at the distal or proximal end of the endoscope to detect the reflected illumination from the flying spot of light. This time sequenced signal is captured by an image processor for display and processing. This technique offers the possibility for very small diameter endoscopes since illumination channel requirements are eliminated. Using various lasers, very specific spectral selectivity can be achieved to optimum contrast of specific lesions of interest. Using several laser lines, or a white light source, with detectors of specific spectral response, multiple spectrally selected images can be acquired simultaneously. The potential for co-linear therapy delivery while imaging is also possible.

  11. The endoscopic endonasal transsphenoidal approach to sellar lesions allows a high radicality: The benefit of angled optics.

    PubMed

    Oertel, Joachim; Gaab, Michael R; Linsler, Stefan

    2016-07-01

    The endonasal endoscopic approach is currently under investigation for perisellar tumour surgery. A higher resection rate is to be expected, and nasal complications should be minimized. Here, the authors report their technique of transnasal endoscopic neurosurgery with a special reference to the impact of the use of angled optics. Two-hundred-and-seventy-one endoscopic endonasal transsphenoidal procedures were performed for sellar lesions between January 2000 and August 2013. One-hundred-and-twenty-nine patients out of them could be used for analysing the use of angled endoscopes including completed follow up, MR imaging as resection control and documentation of the intraoperative use and benefit of angled optics. Exclusion criteria were: planned incomplete resection or incomplete data set. The surgical technique was carefully analysed; and these cases were followed prospectively. Standard technique was a mononostril approach with 0° endoscopes. Angled endoscopes were used for assessment of radicality during the tumour resection and at the end of the procedure. In 95 cases (72%), an angled endoscope was used. Remnant tumour was visualized with angled optics in 27 of the 95 cases (28%). In all these cases, remnant tumour tissue was subsequently further removed. Complete resection was seen on MRI FU in 91 of 95 cases (96%) in this subgroup. In the cases without application of angled optics, there was already a sufficient sight via the 0° endoscope (14/34; 42%), or a significant bleeding from the cavernous sinus made the application of an angled endoscope impossible (19/34; 55%). On follow up, MRI revealed radical tumour resection in 93% (120/129). In the subgroup without angled optics use, radicality reached 88% (30/34) in contrast to 96% in the angled optics subgroup. Recurrent tumour growth was observed in four patients (3%). The endscopic technique has been shown to be safe and successful with a high radicality and only minor complications. The application of various angled endoscopes allows a look "around the corner" resulting in a potentially higher radicality of tumour resection in endonasal transsphenoidal surgery. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. A new rapid test for fecal calprotectin predicts endoscopic remission and postoperative recurrence in Crohn's disease.

    PubMed

    Lobatón, Triana; López-García, Alicia; Rodríguez-Moranta, Francisco; Ruiz, Alexandra; Rodríguez, Lorena; Guardiola, Jordi

    2013-12-01

    Fecal calprotectin (FC), as determined by the enzyme-linked immunoassay (ELISA) test, has been proposed as a promising biomarker of endoscopic activity in Crohn's disease (CD). However data on its accuracy in predicting endoscopic remission according to location and postoperative recurrence (POR) is scarce. Our objective was to evaluate the ability of FC determined by a new quantitative point-of-care test (FC-QPOCT) to predict endoscopic remission and POR in CD patients. FC was determined simultaneously by an enzyme-linked immunoassay test (FC-ELISA) and a FC-QPOCT in CD patients undergoing colonoscopy. Clinical disease activity was assessed according to the Crohn's Disease Activity Index (CDAI). Endoscopic results were assessed according to the Crohn's Disease Endoscopic Activity Index of Severity (CDEIS) and postoperative recurrence according to the Rutgeerts' score. A total of 115 ileocolonoscopies were performed (29 on patients with ileocolonic resection). FC levels correlated more closely with the CDEIS than leucocytes, platelets or CRP. The prediction of "endoscopic remission" (CDEIS<3), using FC-QPOCT (cut-off 272 μg/g) and FC-ELISA (cut-off 274 μg/g) presented an AUC of 0.933 and 0.935 respectively. FC-QPOCT results correlated better with endoscopic activity in the ileocolonic location (Pearson's correlation, r=0.879; P<0.001), than the colonic (r=0.725; P<0.001) or the ileal location (r=0.437; P=0.016). Median FC-QPOCT levels discriminated Rutgeerts' score i0-i1 from i2-i4 (98 (range 30-306) μg/g vs. 234.5 (range 100-612) μg/g respectively, P=0.012). FC determined by rapid quantitative test predicts "endoscopic remission" and endoscopic postoperative recurrence in CD patients. Copyright © 2013 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.

  13. Endoscopic Complete Remission of Crohn Disease After Anti-Tumor Necrosis Factor-α Therapy: CT Enterographic Findings and Their Clinical Implications.

    PubMed

    Kim, Cherry; Park, Seong Ho; Yang, Suk-Kyun; Ye, Byong Duk; Park, Sang Hyoung; Lee, Jong Seok; Kim, Hyun Jin; Kim, Ah Young; Ha, Hyun Kwon

    2016-06-01

    The purpose of this study was to describe the CT enterographic (CTE) findings after endoscopic complete remission (CR) of Crohn disease in patients treated with anti-tumor necrosis factor-α (anti-TNF-α) and the clinical implications of these findings. The records of 27 patients with Crohn disease (14 men, 13 women; mean age, 28.4 ± 8.6 [SD] years) who achieved endoscopic (ileocolonoscopic) CR after anti-TNF-α therapy and underwent CTE both before therapy and at endoscopic CR were identified. Two readers independently assessed the frequencies and severities of mural and perienteric CTE abnormalities, generally regarded as active inflammatory findings, in the terminal ileum and colorectum in the endoscopic CR state and compared them with the corresponding findings before anti-TNF-α therapy. The association between the presence of CTE abnormalities in the face of endoscopic CR and patient outcome during subsequent follow-up was investigated. CTE abnormalities were present in the face of endoscopic CR in 11-18 (26-42%) of 43 bowel sections (18 terminal ileum, 25 colorectum), the most frequent being mural hyperenhancement (21-40%) followed by mural thickening (12-16%). Both findings were mild and unaccompanied by other findings. The frequency and severity of mural and perienteric CTE abnormalities were statistically significantly reduced at endoscopic CR compared with the pre-treatment state. Patients with (n = 10) and without (n = 17) CTE abnormalities at endoscopic CR did not significantly differ with respect to Crohn disease aggravation during subsequent follow-up periods averaging 27.4 and 28.5 months (0/10 versus 2/17, p = 0.516). More than one-fourth of bowel sections in endoscopic CR after anti-TNF-α therapy had residual CTE abnormalities, predominantly mild mural thickening or hyperenhancement. These findings may not have any clinical significance.

  14. Effects of percutaneous endoscopic gastrostomy on survival of patients in a persistent vegetative state after stroke.

    PubMed

    Wu, Kunpeng; Chen, Ying; Yan, Caihong; Huang, Zhijia; Wang, Deming; Gui, Peigen; Bao, Juan

    2017-10-01

    To assess the effect of percutaneous endoscopic gastrostomy on short- and long-term survival of patients in a persistent vegetative state after stroke and determine the relevant prognostic factors. Stroke may lead to a persistent vegetative state, and the effect of percutaneous endoscopic gastrostomy on survival of stroke patients in a persistent vegetative state remains unclear. Prospective study. A total of 97 stroke patients in a persistent vegetative state hospitalised from January 2009 to December 2011 at the Second Hospital, University of South China, were assessed in this study. Percutaneous endoscopic gastrostomy was performed in 55 patients, and mean follow-up time was 18 months. Survival rate and risk factors were analysed. Median survival in the 55 percutaneous endoscopic gastrostomy-treated patients was 17·6 months, higher compared with 8·2 months obtained for the remaining 42 patients without percutaneous endoscopic gastrostomy treatment. Univariate analyses revealed that age, hospitalisation time, percutaneous endoscopic gastrostomy treatment status, family financial situation, family care, pulmonary infection and nutrition were significantly associated with survival. Multivariate analysis indicated that older age, no gastrostomy, poor family care, pulmonary infection and poor nutritional status were independent risk factors affecting survival. Indeed, percutaneous endoscopic gastrostomy significantly improved the nutritional status and decreased pulmonary infection rate in patients with persistent vegetative state after stroke. Interestingly, median survival time was 20·3 months in patients with no or one independent risk factors of poor prognosis (n = 38), longer compared with 8·7 months found for patients with two or more independent risk factors (n = 59). Percutaneous endoscopic gastrostomy significantly improves long-term survival of stroke patients in a persistent vegetative state and is associated with improved nutritional status and decreased pulmonary infection. Percutaneous endoscopic gastrostomy is a promising option for the management of stroke patients in a persistent vegetative state. © 2016 John Wiley & Sons Ltd.

  15. Cooperative laparoscopic endoscopic and hybrid laparoscopic surgery for upper gastrointestinal tumors: Current status

    PubMed Central

    Ntourakis, Dimitrios; Mavrogenis, Georgios

    2015-01-01

    AIM: To investigate the cooperative laparoscopic and endoscopic techniques used for the resection of upper gastrointestinal tumors. METHODS: A systematic research of the literature was performed in PubMed for English and French language articles about laparoscopic and endoscopic cooperative, combined, hybrid and rendezvous techniques. Only original studies using these techniques for the resection of early gastric cancer, benign tumors and gastrointestinal stromal tumors of the stomach and the duodenum were included. By excluding case series of less than 10 patients, 25 studies were identified. The study design, number of cases, tumor pathology size and location, the operative technique name, the endoscopy team and surgical team role, operative time, type of closure of visceral wall defect, blood loss, complications and length of hospital stay of these studies were evaluated. Additionally all cooperative techniques found were classified and are presented in a systematic approach. RESULTS: The studies identified were case series and retrospective cohort studies. A total of 706 patients were operated on with a cooperative technique. The tumors resected were only gastrointestinal stromal tumors (GIST) in 4 studies, GIST and various benign submucosal tumors in 22 studies, early gastric cancer (pT1a and pT1b) in 6 studies and early duodenal cancer in 1 study. There was important heterogeneity between the studies. The operative techniques identified were: laparoscopic assisted endoscopic resection, endoscopic assisted wedge resection, endoscopic assisted transgastric and intragastric surgery, laparoscopic endoscopic cooperative surgery (LECS), laparoscopic assisted endoscopic full thickness resection (LAEFR), clean non exposure technique and non-exposed endoscopic wall-inversion surgery (NEWS). Each technique is illustrated with the roles of the endoscopic and laparoscopic teams; the indications, characteristics and short term results are described. CONCLUSION: Along with the traditional cooperative techniques, new procedures like LECS, LAEFR and NEWS hold great promise for the future of minimally invasive oncologic procedures. PMID:26604655

  16. Proof-of-concept of a laser mounted endoscope for touch-less navigated procedures

    PubMed Central

    Kral, Florian; Gueler, Oezguer; Perwoeg, Martina; Bardosi, Zoltan; Puschban, Elisabeth J; Riechelmann, Herbert; Freysinger, Wolfgang

    2013-01-01

    Background and Objectives During navigated procedures a tracked pointing device is used to define target structures in the patient to visualize its position in a registered radiologic data set. When working with endoscopes in minimal invasive procedures, the target region is often difficult to reach and changing instruments is disturbing in a challenging, crucial moment of the procedure. We developed a device for touch less navigation during navigated endoscopic procedures. Materials and Methods A laser beam is delivered to the tip of a tracked endoscope angled to its axis. Thereby the position of the laser spot in the video-endoscopic images changes according to the distance between the tip of the endoscope and the target structure. A mathematical function is defined by a calibration process and is used to calculate the distance between the tip of the endoscope and the target. The tracked tip of the endoscope and the calculated distance is used to visualize the laser spot in the registered radiologic data set. Results In comparison to the tracked instrument, the touch less target definition with the laser spot yielded in an over and above error of 0.12 mm. The overall application error in this experimental setup with a plastic head was 0.61 ± 0.97 mm (95% CI −1.3 to +2.5 mm). Conclusion Integrating a laser in an endoscope and then calculating the distance to a target structure by image processing of the video endoscopic images is accurate. This technology eliminates the need for tracked probes intraoperatively and therefore allows navigation to be integrated seamlessly in clinical routine. However, it is an additional chain link in the sequence of computer-assisted surgery thus influencing the application error. Lasers Surg. Med. 45:377–382, 2013. © 2013 Wiley Periodicals, Inc. PMID:23737122

  17. Clinical study using novel endoscopic system for measuring size of gastrointestinal lesion

    PubMed Central

    Oka, Kiyoshi; Seki, Takeshi; Akatsu, Tomohiro; Wakabayashi, Takao; Inui, Kazuo; Yoshino, Junji

    2014-01-01

    AIM: To verify the performance of a lesion size measurement system through a clinical study. METHODS: Our proposed system, which consists of a conventional endoscope, an optical device, an optical probe, and a personal computer, generates a grid scale to measure the lesion size from an endoscopic image. The width of the grid scale is constantly adjusted according to the distance between the tip of the endoscope and lesion because the lesion size on an endoscopic image changes according to the distance. The shape of the grid scale was corrected to match the distortion of the endoscopic image. The distance was calculated using the amount of laser light reflected from the lesion through an optical probe inserted into the instrument channel of the endoscope. The endoscopist can thus measure the lesion size without contact by comparing the lesion with the size of the grid scale on the endoscopic image. (1) A basic test was performed to verify the relationship between the measurement error eM and the tilt angle of the endoscope; and (2) The sizes of three colon polyps were measured using our system during endoscopy. These sizes were immediately measured by scale after their removal. RESULTS: There was no error at α = 0°. In addition, the values of eM (mean ± SD) were 0.24 ± 0.11 mm (α = 10°), 0.90 ± 0.58 mm (α = 20°) and 2.31 ± 1.41 mm (α = 30°). According to these results, our system has been confirmed to measure accurately when the tilt angle is less than 20°. The measurement error was approximately 1 mm in the clinical study. Therefore, it was concluded that our proposed measurement system was also effective in clinical examinations. CONCLUSION: By combining simple optical equipment with a conventional endoscope, a quick and accurate system for measuring lesion size was established. PMID:24744595

  18. Wireless Acoustic-Surface Actuators for Miniaturized Endoscopes.

    PubMed

    Qiu, Tian; Adams, Fabian; Palagi, Stefano; Melde, Kai; Mark, Andrew; Wetterauer, Ulrich; Miernik, Arkadiusz; Fischer, Peer

    2017-12-13

    Endoscopy enables minimally invasive procedures in many medical fields, such as urology. However, current endoscopes are normally cable-driven, which limits their dexterity and makes them hard to miniaturize. Indeed, current urological endoscopes have an outer diameter of about 3 mm and still only possess one bending degree-of-freedom. In this article, we report a novel wireless actuation mechanism that increases the dexterity and that permits the miniaturization of a urological endoscope. The novel actuator consists of thin active surfaces that can be readily attached to any device and are wirelessly powered by ultrasound. The surfaces consist of two-dimensional arrays of microbubbles, which oscillate under ultrasound excitation and thereby generate an acoustic streaming force. Bubbles of different sizes are addressed by their unique resonance frequency, thus multiple degrees-of-freedom can readily be incorporated. Two active miniaturized devices (with a side length of around 1 mm) are demonstrated: a miniaturized mechanical arm that realizes two degrees-of-freedom, and a flexible endoscope prototype equipped with a camera at the tip. With the flexible endoscope, an active endoscopic examination is successfully performed in a rabbit bladder. The results show the potential medical applicability of surface actuators wirelessly powered by ultrasound penetrating through biological tissues.

  19. [Significance of working environment improvement based on determination of source of harmful substance--example of an endoscope syringe room using glutaraldehyde].

    PubMed

    Tashiro, Hiraku; Oda, Susumu; Mori, Koji

    2004-03-01

    Because a worker complained of irritated eyes and throat due to glutaraldehyde (GA) in an endoscope syringe room, the automated endoscope washers and GA liquid stored in reserve were isolated in a separate room. A ventilation system was installed in this room, and the packing of the automated endoscope washers was changed. However, since the obnoxious smell of GA still remained in the endoscope syringe room, we had to determine the source of the smell. A plastic bucket with a cap was found to be filled with GA for disinfection of the endoscope apparatus. GA had evaporated when dispersed around the bucket, resulting in the obnoxious smell. The plastic bucket was replaced with a different type of container. Moreover, GA from the separate room did not affect the concentration of GA in the working area because the separate room for the automated endoscope washers had twice the ventilation volume proposed by the guidelines of the Society of Gastroenterology Nurses and Associates of the USA and the Healthcare Engineering Association of Japan. Consequently, we reconfirmed the significance of working environment improvement after clarifying the source of the harmful substance.

  20. Endoscopic Transmaxillary Transposition of Temporalis Flap for Recurrent Cerebrospinal Fluid Leak Closure.

    PubMed

    Thomas, Regi; Girishan, Shabari; Chacko, Ari George

    2016-12-01

    Objective  To describe the technique of endoscopic transmaxillary temporalis muscle flap transposition for the repair of a persistent postoperative sphenoidal cerebrospinal fluid leak. Design  The repair of a recurrent cerebrospinal fluid leak for a patient who had undergone endoscopic transsphenoidal excision of an invasive silent corticotroph Hardy C and Knosp Grade IV pituitary adenoma was undertaken. The patient had completed postoperative radiotherapy for the residual tumor and presented with cerebrospinal fluid leak, 1 year later. The initial two attempts to repair the cerebrospinal fluid leak with free grafts failed. Therefore, an endoscopic transmaxillary transposition of the temporalis muscle flap was attempted to stop the cerebrospinal fluid leak. Results  The endoscopic transmaxillary transposition of the vascularized temporalis muscle flap onto the cerebrospinal fluid leak repair site resulted in successful closure of the cerebrospinal fluid leak. Conclusion  Endoscopic transmaxillary transposition of the temporalis flap resulted in closure of recurrent cerebrospinal fluid leak in a patient with recurrent pituitary adenoma, who had undergone previous surgery and radiotherapy. This technique has advantages over the endoscopic transpterygoid transposition of the same flap and could be used as a complementary technique in selected patients.

  1. Terahertz endoscopic imaging for colorectal cancer detection: Current status and future perspectives

    PubMed Central

    Doradla, Pallavi; Joseph, Cecil; Giles, Robert H

    2017-01-01

    Terahertz (THz) imaging is progressing as a robust platform for myriad applications in the field of security, health, and material science. The THz regime, which comprises wavelengths spanning from microns to millimeters, is non-ionizing and has very low photon energy: Making it inherently safe for biological imaging. Colorectal cancer is one of the most common causes of death in the world, while the conventional screening and standard of care yet relies exclusively on the physician’s experience. Researchers have been working on the development of a flexible THz endoscope, as a potential tool to aid in colorectal cancer screening. This involves building a single-channel THz endoscope, and profiling the THz response from colorectal tissue, and demonstrating endogenous contrast levels between normal and diseased tissue when imaging in reflection modality. The current level of contrast provided by the prototype THz endoscopic system represents a significant step towards clinical endoscopic application of THz technology for in-vivo colorectal cancer screening. The aim of this paper is to provide a short review of the recent advances in THz endoscopic technology and cancer imaging. In particular, the potential of single-channel THz endoscopic imaging for colonic cancer screening will be highlighted. PMID:28874955

  2. A comparative analysis of online education resources for patients undergoing endoscopic transsphenoidal surgery.

    PubMed

    Fahey, Natalie; Patel, Vimal; Rosseau, Gail

    2014-12-01

    Endoscopic transsphenoidal surgery has become the most commonly performed surgical procedure for pituitary tumor removal. As such, there are many patient-oriented educational materials on the technique available online for members of the public who desire to learn more about the surgery. It has been recommended that educational resources be written to the national average reading level, which in the United States is between sixth and seventh grade. This study assesses the reading level of the educational materials currently available online for endoscopic transsphenoidal surgery and determines whether these resources are written at a suitable comprehension level for most readers. Sixteen patient educational resources describing endoscopic transsphenoidal surgery were identified online and assessed using 4 standard readability assessments. Patient educational resources written for endoscopic transsphenoidal surgery are written far above the recommended reading level of sixth grade. The online educational resources written for patients about endoscopic transsphenoidal surgery are above the recommended reading level for patient education materials. Further revisions to simplify these resources on endoscopic transsphenoidal surgery are needed to ensure that most patients can comprehend this important material and make informed decisions about their health care. Copyright © 2014. Published by Elsevier Inc.

  3. [Endonasal skull base endoscopy].

    PubMed

    Simal-Julián, Juan Antonio; Miranda-Lloret, Pablo; Pancucci, Giovanni; Evangelista-Zamora, Rocío; Pérez-Borredá, Pedro; Sanromán-Álvarez, Pablo; Perez-de-Sanromán, Laila; Botella-Asunción, Carlos

    2013-01-01

    The endoscopic endonasal techniques used in skull base surgery have evolved greatly in recent years. Our study objective was to perform a qualitative systematic review of the likewise systematic reviews in published English language literature, to examine the evidence and conclusions reached in these studies comparing transcranial and endoscopic approaches in skull base surgery. We searched the references on the MEDLINE and EMBASE electronic databases selecting the systematic reviews, meta-analyses and evidence based medicine reviews on skull based pathologies published from January 2000 until January 2013. We focused on endoscopic impact and on microsurgical and endoscopic technique comparisons. Full endoscopic endonasal approaches achieved gross total removal rates of craniopharyngiomas and chordomas higher than those for transcranial approaches. In anterior skull base meningiomas, complete resections were more frequently achieved after transcranial approaches, with a trend in favour of endoscopy with respect to visual prognosis. Endoscopic endonasal approaches minimised the postoperative complications after the treatment of cerebrospinal fluid (CSF) leaks, encephaloceles, meningoceles, craniopharyngiomas and chordomas, with the exception of postoperative CSF leaks. Randomized multicenter studies are necessary to resolve the controversy over endoscopic and microsurgical approaches in skull base surgery. Copyright © 2013 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  4. Towards standardized assessment of endoscope optical performance: geometric distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Desai, Viraj N.; Ngo, Ying Z.; Cheng, Wei-Chung; Pfefer, Joshua

    2013-12-01

    Technological advances in endoscopes, such as capsule, ultrathin and disposable devices, promise significant improvements in safety, clinical effectiveness and patient acceptance. Unfortunately, the industry lacks test methods for preclinical evaluation of key optical performance characteristics (OPCs) of endoscopic devices that are quantitative, objective and well-validated. As a result, it is difficult for researchers and developers to compare image quality and evaluate equivalence to, or improvement upon, prior technologies. While endoscope OPCs include resolution, field of view, and depth of field, among others, our focus in this paper is geometric image distortion. We reviewed specific test methods for distortion and then developed an objective, quantitative test method based on well-defined experimental and data processing steps to evaluate radial distortion in the full field of view of an endoscopic imaging system. Our measurements and analyses showed that a second-degree polynomial equation could well describe the radial distortion curve of a traditional endoscope. The distortion evaluation method was effective for correcting the image and can be used to explain other widely accepted evaluation methods such as picture height distortion. Development of consensus standards based on promising test methods for image quality assessment, such as the method studied here, will facilitate clinical implementation of innovative endoscopic devices.

  5. Wireless Acoustic-Surface Actuators for Miniaturized Endoscopes

    PubMed Central

    2017-01-01

    Endoscopy enables minimally invasive procedures in many medical fields, such as urology. However, current endoscopes are normally cable-driven, which limits their dexterity and makes them hard to miniaturize. Indeed, current urological endoscopes have an outer diameter of about 3 mm and still only possess one bending degree-of-freedom. In this article, we report a novel wireless actuation mechanism that increases the dexterity and that permits the miniaturization of a urological endoscope. The novel actuator consists of thin active surfaces that can be readily attached to any device and are wirelessly powered by ultrasound. The surfaces consist of two-dimensional arrays of microbubbles, which oscillate under ultrasound excitation and thereby generate an acoustic streaming force. Bubbles of different sizes are addressed by their unique resonance frequency, thus multiple degrees-of-freedom can readily be incorporated. Two active miniaturized devices (with a side length of around 1 mm) are demonstrated: a miniaturized mechanical arm that realizes two degrees-of-freedom, and a flexible endoscope prototype equipped with a camera at the tip. With the flexible endoscope, an active endoscopic examination is successfully performed in a rabbit bladder. The results show the potential medical applicability of surface actuators wirelessly powered by ultrasound penetrating through biological tissues. PMID:29148713

  6. Sedation assisted by an endoscopist (SAE) for complex endoscopic procedures. Is it time to change the current guidelines?

    PubMed

    Hernán Ocaña, Pablo

    2018-04-01

    Currently, sedation in endoscopic procedures is considered a necessary condition and a criterion of quality in digestive endoscopy. The role of SAE in conventional endoscopic procedures is clearly established in clinical guidelines, but this is not so clear in complex endoscopic procedures, such as ERCP. In recent years, numerous studies have been published, with results similar to those noticed in this article, endorsing the safety, efficacy and efficiency of SAE, when performed by properly trained staff.

  7. Endoscopic Bubble Trouble: Hyperbaric Oxygen Therapy for Cerebral Gas Embolism During Upper Endoscopy.

    PubMed

    Cooper, Jeffrey S; Thomas, Jason; Singh, Shailender; Brakke, Tarra

    2017-07-01

    Gas embolism is a rare but potentially devastating complication of endoscopic procedures. We describe 3 cases of gas embolism which were associated with endoscopic procedures (esophagogastroduodenoscopy and endoscopic retrograde cholangiopancreatography). We treated these at our hyperbaric medicine center with 3 different outcomes: complete resolution, death, and disability. We review the literature regarding this unusual complication of endoscopy and discuss the need for prompt identification and referral for hyperbaric oxygen therapy. Additional adjunctive therapies are also discussed.

  8. Endoscopic surgery of the nose and paranasal sinus.

    PubMed

    Palmer, Orville; Moche, Jason A; Matthews, Stanley

    2012-05-01

    Mucosal preservation is of paramount importance in the diagnosis and surgical management of the sinonasal tract. The endoscope revolutionized the practice of endoscopic nasal surgery. As a result, external sinus surgery is performed less frequently today, and more emphasis is placed on functional endoscopy and preservation of normal anatomy. Endoscopic surgery of the nose and paranasal sinus has provided improved surgical outcomes and has shortened the length of stay in hospital. It has also become a valuable teaching tool. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Fiberoptic endoscopic-assisted diverticulotomy: a novel technique for the management of Zenker's diverticulum.

    PubMed

    Altman, Jason I; Genden, Eric M; Moche, Jason

    2005-05-01

    Endoscopic diverticulotomy is rapidly becoming the procedure of choice for treatment of Zenker's diverticulum. The endoscopic approach has resulted in significant decreases in patient morbidity, time to resumption of oral intake, and overall cost as compared with open treatment. However, a small but significant patient population is unable to accommodate the rigid laryngoscope and therefore requires open treatment. We present a novel technique, flexible fiberoptic endoscopic-assisted diverticulotomy, for the management of patients who are unable to undergo rigid endoscopy.

  10. Comparison of low-temperature hydrogen peroxide gas plasma sterilization for endoscopes using various Sterrad models.

    PubMed

    Okpara-Hofmann, J; Knoll, M; Dürr, M; Schmitt, B; Borneff-Lipp, M

    2005-04-01

    This study compared the effectiveness of sterilizing four types of endoscope using different models of the Sterrad system (Sterrad 50, 100, 100S and 200). Sterilization levels meeting international requirements were attained in all cases with carriers inoculated with Geobacillus stearothermophilus spores. The endoscopes were tested in half cycles ('overkill'). This is the first study to compare the Sterrad models marketed to date in terms of effective sterilization of endoscopes with narrow lumens.

  11. Transnasal Endoscope Locked in a Bent Position Causing Difficult Withdrawal

    PubMed Central

    Kumada, Takashi; Hisanaga, Yasuhiro

    2014-01-01

    We report a rare but severe complication of routine transnasal esophagogastroduodenoscopy (EGD). The tip of a transnasal endoscope was locked in a bent position. Since the bent tip was unable to be returned to a neutral position, the snare from another endoscope inserted transorally was used to straighten it, which allowed the transnasal endoscope to be withdrawn with only mild injury to the gastric mucosa. Endoscopists should be aware of this complication and how to manage it. PMID:26157831

  12. Prevention and Treatment of Esophageal Stenosis after Endoscopic Submucosal Dissection for Early Esophageal Cancer

    PubMed Central

    Wen, Jing; Lu, Zhongsheng; Liu, Qingsen

    2014-01-01

    Endoscopic submucosal dissection (ESD) for the treatment of esophageal mucosal lesions is associated with a risk of esophageal stenosis, especially for near-circumferential or circumferential esophageal mucosal defects. Here, we review historic and modern studies on the prevention and treatment of esophageal stenosis after ESD. These methods include prevention via pharmacological treatment, endoscopic autologous cell transplantation, endoscopic esophageal dilatation, and stent placement. This short review will focus on direct prevention and treatment, which may help guide the way forward. PMID:25386186

  13. Endoscopic papillectomy: risk factors for incomplete resection and recurrence during long-term follow-up.

    PubMed

    Ridtitid, Wiriyaporn; Tan, Damien; Schmidt, Suzette E; Fogel, Evan L; McHenry, Lee; Watkins, James L; Lehman, Glen A; Sherman, Stuart; Coté, Gregory A

    2014-02-01

    Endoscopic papillectomy is increasingly used as an alternative to surgery for ampullary adenomas and other noninvasive ampullary lesions. To measure short-term safety and efficacy of endoscopic papillectomy, define patient and lesion characteristics associated with incomplete endoscopic resection, and measure adenoma recurrence rates during long-term follow-up. Retrospective cohort study. Tertiary-care academic medical center. All patients who underwent endoscopic papillectomy for ampullary lesions between July 1995 and June 2012. Endoscopic papillectomy. Patient and lesion characteristics associated with incomplete endoscopic resection and ampullary adenoma-free survival analysis. We identified 182 patients who underwent endoscopic papillectomy, 134 (73.6%) having complete resection. Short-term adverse events occurred in 34 (18.7%). Risk factors for incomplete resection were jaundice at presentation (odds ratio [OR] 0.21; 95% confidence interval [CI] 0.07-0.69; P = .009), occult adenocarcinoma (OR 0.06; 95% CI, 0.01-0.36; P = .002), and intraductal involvement (OR 0.29; 95% CI, 0.11-0.75; P = .011). The en bloc resection technique was strongly associated with a higher rate of complete resection (OR 4.05; 95% CI, 1.71-9.59; P = .001). Among patients with ampullary adenoma who had complete resection (n = 107), 16 patients (15%) developed recurrence up to 65 months after resection. Retrospective analysis. Jaundice at presentation, occult adenocarcinoma in the resected specimen, and intraductal involvement are associated with a lower rate of complete resection, whereas en bloc papillectomy increases the odds of complete endoscopic resection. Despite complete resection, recurrence was observed up to 5 years after papillectomy, confirming the need for long-term surveillance. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  14. Advanced endoscopic imaging: European Society of Gastrointestinal Endoscopy (ESGE) Technology Review.

    PubMed

    East, James E; Vleugels, Jasper L; Roelandt, Philip; Bhandari, Pradeep; Bisschops, Raf; Dekker, Evelien; Hassan, Cesare; Horgan, Gareth; Kiesslich, Ralf; Longcroft-Wheaton, Gaius; Wilson, Ana; Dumonceau, Jean-Marc

    2016-11-01

    Background and aim: This technical review is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the utilization of advanced endoscopic imaging in gastrointestinal (GI) endoscopy. Methods: This technical review is based on a systematic literature search to evaluate the evidence supporting the use of advanced endoscopic imaging throughout the GI tract. Technologies considered include narrowed-spectrum endoscopy (narrow band imaging [NBI]; flexible spectral imaging color enhancement [FICE]; i-Scan digital contrast [I-SCAN]), autofluorescence imaging (AFI), and confocal laser endomicroscopy (CLE). The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was adopted to define the strength of recommendation and the quality of evidence. Main recommendations: 1. We suggest advanced endoscopic imaging technologies improve mucosal visualization and enhance fine structural and microvascular detail. Expert endoscopic diagnosis may be improved by advanced imaging, but as yet in community-based practice no technology has been shown consistently to be diagnostically superior to current practice with high definition white light. (Low quality evidence.) 2. We recommend the use of validated classification systems to support the use of optical diagnosis with advanced endoscopic imaging in the upper and lower GI tracts (strong recommendation, moderate quality evidence). 3. We suggest that training improves performance in the use of advanced endoscopic imaging techniques and that it is a prerequisite for use in clinical practice. A learning curve exists and training alone does not guarantee sustained high performances in clinical practice. (Weak recommendation, low quality evidence.) Conclusion: Advanced endoscopic imaging can improve mucosal visualization and endoscopic diagnosis; however it requires training and the use of validated classification systems. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Evaluation of a novel multi-articulated endoscope: proof of concept through a virtual simulation.

    PubMed

    Karvonen, Tuukka; Muranishi, Yusuke; Yamamoto, Goshiro; Kuroda, Tomohiro; Sato, Toshihiko

    2017-07-01

    In endoscopic surgery such as video-assisted thoracoscopic surgery and laparoscopic surgery, providing the surgeon a good view of the target is important. Rigid endoscope has for years been the go-to tool for this purpose, but it has certain limitations like the inability to work around obstacles. To improve on current tools, a novel multi-articulated endoscope (MAE) is currently under development. To investigate its feasibility and possible value, we performed a user test using virtual prototype of the MAE with the intent to show that it outperforms the conventional endoscope while bringing minimal additional burden to the operator. To evaluate the prototype, we built a virtual model of the MAE and a rigid oblique-viewing endoscope. Through a comparative user study we evaluate the ability of each device to visualize certain targets placed inside the virtual chest cavity by the angle between the visual axis of the scope and the normal of the plane of the target, while accounting for the usability of each endoscope by recording the time taken for each task. In addition, we collected a questionnaire from each participant to obtain feedback. The angles obtained using the MAE were smaller on average ([Formula: see text]), indicating that better visualization can be achieved through the proposed method. A nonsignificant difference in mean time taken for each task in favor of the rigid endoscope was also found ([Formula: see text]). We have demonstrated that better visualization for endoscopic surgery can be achieved through our novel MAE. The scope may bring about a paradigm shift in the field of minimally invasive surgery by providing more freedom in viewpoint selection, enabling surgeons to perform more elaborate procedures in minimally invasive settings.

  16. Percutaneous biliary approach as a successful rescue procedure after failed endoscopic therapy for drainage in advanced hilar tumors.

    PubMed

    Jang, Sung Ill; Hwang, Jin-Hyeok; Lee, Kwang-Hun; Yu, Jeong-Sik; Kim, Hee Wook; Yoon, Chang Jin; Lee, Yoon Suk; Paik, Kyu Hyun; Lee, Sang Hyub; Lee, Dong Ki

    2017-04-01

    Palliative endoscopic or percutaneous biliary drainage is used for unresectable advanced hilar cancer (HC). The best option for drainage in Bismuth type III or IV HC has not been established. The aims of this study are to identify factors predictive of endoscopic stenting failure and evaluate the effectiveness of rescue percutaneous stenting in patients with advanced HC. Data from 110 patients with inoperable advanced HC were retrospectively reviewed. All received bilateral self-expandable metallic stents. Patients were divided into three groups: I, successful initial endoscopic stenting; II, unsuccessful initial endoscopic stenting, followed by percutaneous stenting; and III, initial percutaneous stenting. We analyzed clinical results and radiologic tumor characteristics. Baseline characteristics and clinical outcomes of all groups were similar, except the hospital stay was longer in group III than group I. Technical success rate was higher in groups II and III (100%) than in group I (72.4%). The functional success rate, stent patency time, patient survival time, and complication rate were similar between groups. Endoscopic stenting failed because of guide-wire passage failure (n = 12) or stent passage failure (n = 7). The only factor significantly associated with endoscopic failure was a smaller left intrahepatic duct-common bile duct angle. As clinical outcomes were generally similar between approaches, percutaneous stenting is recommended for patients with Bismuth type III or IV advanced HC. Acute left intrahepatic duct-common bile duct angulation predicts endoscopic stenting failure. If endoscopic stenting fails, immediate conversion to the percutaneous approach is a necessary and effective rescue method. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  17. The Incidence of Complications in Single-stage Endoscopic Stone Removal for Patients with Common Bile Duct Stones: A Propensity Score Analysis.

    PubMed

    Saito, Hirokazu; Kadono, Yoshihiro; Kamikawa, Kentaro; Urata, Atsushi; Imamura, Haruo; Matsushita, Ikuo; Kakuma, Tatsuyuki; Tada, Shuji

    2018-02-15

    Objective Single-stage endoscopic stone removal for choledocholithiasis is an advantageous approach because it is associated with a shorter hospital stay; however, few studies have reported the incidence of complications related to this procedure in detail. The aim of this study was to examine the incidence of complications and efficacy of this procedure. Methods This retrospective study investigated the incidence of complications in 345 patients with naive papilla who underwent therapeutic endoscopic retrograde cholangiopancreatography (ERCP) for choledocholithiasis at three institutions between April 2014 and March 2016 by a propensity score analysis. The efficacy of single-stage endoscopic stone removal was assessed based on a hospital stay of within 7 days and the number of ERCP attempts. Results Among 114 patients who underwent single-stage endoscopic stone removal, 15 patients (13.2%) experienced complications. Among the remaining 231 patients in the two-stage endoscopic stone removal group, complications were observed in 17 patients (7.4%). The propensity score analysis, which was adjusted for confounding factors, revealed that single-stage endoscopic stone removal was not a significant risk factor for complications (p=0.52). In patients in whom >10 min was required for deep cannulation, single-stage endoscopic stone removal was not a significant risk factor for complications in the propensity score analysis (p=0.37). In the single-stage group, the proportion of patients with a hospital stay of within 7 days was significantly higher and the number of ERCP attempts was significantly lower in comparison to the two-stage group (p <0.0001 and <0.0001, respectively). Conclusion Single-stage endoscopic stone removal did not increase the incidence of complications associated with ERCP and was effective for reducing the hospital stay and the number of ERCP attempts.

  18. The Incidence of Complications in Single-stage Endoscopic Stone Removal for Patients with Common Bile Duct Stones: A Propensity Score Analysis

    PubMed Central

    Saito, Hirokazu; Kadono, Yoshihiro; Kamikawa, Kentaro; Urata, Atsushi; Imamura, Haruo; Matsushita, Ikuo; Kakuma, Tatsuyuki; Tada, Shuji

    2017-01-01

    Objective Single-stage endoscopic stone removal for choledocholithiasis is an advantageous approach because it is associated with a shorter hospital stay; however, few studies have reported the incidence of complications related to this procedure in detail. The aim of this study was to examine the incidence of complications and efficacy of this procedure. Methods This retrospective study investigated the incidence of complications in 345 patients with naive papilla who underwent therapeutic endoscopic retrograde cholangiopancreatography (ERCP) for choledocholithiasis at three institutions between April 2014 and March 2016 by a propensity score analysis. The efficacy of single-stage endoscopic stone removal was assessed based on a hospital stay of within 7 days and the number of ERCP attempts. Results Among 114 patients who underwent single-stage endoscopic stone removal, 15 patients (13.2%) experienced complications. Among the remaining 231 patients in the two-stage endoscopic stone removal group, complications were observed in 17 patients (7.4%). The propensity score analysis, which was adjusted for confounding factors, revealed that single-stage endoscopic stone removal was not a significant risk factor for complications (p=0.52). In patients in whom >10 min was required for deep cannulation, single-stage endoscopic stone removal was not a significant risk factor for complications in the propensity score analysis (p=0.37). In the single-stage group, the proportion of patients with a hospital stay of within 7 days was significantly higher and the number of ERCP attempts was significantly lower in comparison to the two-stage group (p <0.0001 and <0.0001, respectively). Conclusion Single-stage endoscopic stone removal did not increase the incidence of complications associated with ERCP and was effective for reducing the hospital stay and the number of ERCP attempts. PMID:29151506

  19. Design of wormlike automated robotic endoscope: dynamic interaction between endoscopic balloon and surrounding tissues.

    PubMed

    Poon, Carmen C Y; Leung, Billy; Chan, Cecilia K W; Lau, James Y W; Chiu, Philip W Y

    2016-02-01

    The current design of capsule endoscope is limited by the inability to control the motion within gastrointestinal tract. The rising incidence of gastrointestinal cancers urged improvement in the method of screening endoscopy. This preclinical study aimed to design and develop a novel locomotive module for capsule endoscope. We investigated the feasibility and physical properties of this newly designed caterpillar-like capsule endoscope with a view to enhancing screening endoscopy. This study consisted of preclinical design and experimental testing on the feasibility of automated locomotion for a prototype caterpillar endoscope. The movement was examined first in the PVC tube and then in porcine intestine. The image captured was transmitted to handheld device to confirm the control of movement. The balloon pressure and volume as well as the contact force between the balloon and surroundings were measured when the balloon was inflated inside (1) a hard PVC tube, (2) a soft PVC tube, (3) muscular sites of porcine colons and (4) less muscular sites of porcine colons. The prototype caterpillar endoscope was able to move inward and backward within the PVC tubing and porcine intestine. Images were able to be captured from the capsule endoscope attached and being observed with a handheld device. Using the onset of a contact force as indication of the buildup of the gripping force between the balloon and the lumen walls, it is concluded from the results of this study that the rate of change in balloon pressure and volume is two good estimators to optimize the inflation of the balloon. The results of this study will facilitate further refinement in the design of caterpillar robotic endoscope to move inside the GI tract.

  20. Conjugation of fiber-coupled wide-band light sources and acousto-optical spectral elements

    NASA Astrophysics Data System (ADS)

    Machikhin, Alexander; Batshev, Vladislav; Polschikova, Olga; Khokhlov, Demid; Pozhar, Vitold; Gorevoy, Alexey

    2017-12-01

    Endoscopic instrumentation is widely used for diagnostics and surgery. The imaging systems, which provide the hyperspectral information of the tissues accessible by endoscopes, are particularly interesting and promising for in vivo photoluminescence diagnostics and therapy of tumour and inflammatory diseases. To add the spectral imaging feature to standard video endoscopes, we propose to implement acousto-optical (AO) filtration of wide-band illumination of incandescent-lamp-based light sources. To collect maximum light and direct it to the fiber-optic light guide inside the endoscopic probe, we have developed and tested the optical system for coupling the light source, the acousto-optical tunable filter (AOTF) and the light guide. The system is compact and compatible with the standard endoscopic components.

  1. Per-oral endoscopic myotomy (POEM) for esophageal achalasia.

    PubMed

    Pescarus, Radu; Shlomovitz, Eran; Swanstrom, Lee L

    2014-01-01

    Per-oral endoscopic myotomy (POEM) is a new minimally invasive endoscopic treatment for achalasia. Since the first modern human cases were published in 2008, around 2,000 cases have been performed worldwide. This technique requires advanced endoscopic skills and a learning curve of at least 20 cases. POEM is highly successful with over 90 % improvement in dysphagia while offering patients the advantage of a low impact endoscopic access. The main long-term complication is gastroesophageal reflux (GER) with an estimated incidence of 35 %, similar to the incidence of GER post-laparoscopic Heller with fundoplication. Although POEM represents a paradigm shift in the treatment of achalasia, more long-term data are clearly needed to further define its role in the treatment algorithm of this rare disease.

  2. Endoscopically Assisted Drilling, Exposure of the Fundus through a Presigmoid Retrolabyrinthine Approach: A Cadaveric Feasibility Study.

    PubMed

    Muelleman, Thomas; Shew, Matthew; Alvi, Sameer; Shah, Kushal; Staecker, Hinrich; Chamoun, Roukouz; Lin, James

    2018-01-01

    The presigmoid retrolabyrinthine approach to the cerebellopontine angle is traditionally described to not provide access to the internal auditory canal (IAC). We aimed to evaluate the extent of the IAC that could be exposed with endoscopically assisted drilling and to measure the percentage of the IAC that could be visualized with the microscope and various endoscopes after drilling had been completed. Presigmoid retrolabyrinthine approaches were performed bilaterally on 4 fresh cadaveric heads. We performed endoscopically assisted drilling to expose the fundus of the IAC, which resulted in exposure of the entire IAC in 8 of 8 temporal bone specimens. The microscope afforded a mean view of 83% (n = 8) of the IAC. The 0°, 30°, 45°, and 70° endoscope each afforded a view of 100% of the IAC in 8 of 8 temporal bone specimens. In conclusion, endoscopic drilling of the IAC of can provide an extradural means of exposing the entire length of the IAC while preserving the labyrinth.

  3. New developments in endoscopic treatment of chronic pancreatitis.

    PubMed

    Didden, P; Bruno, M; Poley, J W

    2012-12-01

    The aim of endoscopic therapy of chronic pancreatitis (CP) is to treat pain by draining the pancreatic duct or managing loco-regional complications. Recent decennia were characterized by continuous improvement of endoscopic techniques and devices, resulting in a better clinical outcome. Novel developments now also provide the opportunity to endoscopically treat refractory CP-related complications. Especially suboptimal surgical candidates could potentially benefit from these new developments, consequently avoiding invasive surgery. The use of fully covered self-expandable metal stents (SEMS) has been explored in pancreatic and CP-related biliary duct strictures, resistant to conventional treatment with plastic endoprotheses. Furthermore, endosonography-guided transmural drainage of the main pancreatic duct via duct-gastrostomy is an alternative treatment option in selected cases. Pancreatic pseudocysts represent an excellent indication for endoscopic therapy with some recent case series demonstrating effective drainage with the use of a fully covered SEMS. Although results of these new endoscopic developments are promising, high quality randomized trials are required to determine their definite role in the management of chronic pancreatitis.

  4. Coblation-assisted endonasal endoscopic resection of juvenile nasopharyngeal angiofibroma.

    PubMed

    Ye, L; Zhou, X; Li, J; Jin, J

    2011-09-01

    Juvenile nasopharyngeal angiofibroma may be successfully resected using endoscopic techniques. However, the use of coblation technology for such resection has not been described. This study aimed to document cases of Fisch class I juvenile nasopharyngeal angiofibroma with limited nasopharyngeal and nasal cavity extension, which were completely resected using an endoscopic coblation technique. We retrospectively studied 23 patients with juvenile nasopharyngeal angiofibroma who underwent resection with either traditional endoscopic instruments (n = 12) or coblation (n = 11). Intra-operative blood loss and overall operative time were recorded. The mean tumour resection time for coblation and traditional endoscopic instruments was 87 and 136 minutes, respectively (t = 9.962, p < 0.001). Mean intra-operative blood loss was 121 and 420 ml, respectively (t = 28.944, p < 0.001), a significant difference. Both techniques achieved complete tumour resection with minimal damage to adjacent tissues, and no recurrence in any patient. Coblation successfully achieves transnasal endoscopic resection of juvenile nasopharyngeal angiofibroma (Fisch class I), with good surgical margins and minimal blood loss.

  5. Sterilization of endoscopic instruments.

    PubMed

    Sabnis, Ravindra B; Bhattu, Amit; Vijaykumar, Mohankumar

    2014-03-01

    Sterilization of endoscopic instruments is an important but often ignored topic. The purpose of this article is to review the current literature on the sterilization of endoscopic instruments and elaborate on the appropriate sterilization practices. Autoclaving is an economic and excellent method of sterilizing the instruments that are not heat sensitive. Heat sensitive instruments may get damaged with hot sterilization methods. Several new endoscopic instruments such as flexible ureteroscopes, chip on tip endoscopes, are added in urologists armamentarium. Many of these instruments are heat sensitive and hence alternative efficacious methods of sterilization are necessary. Although ethylene oxide and hydrogen peroxide are excellent methods of sterilization, they have some drawbacks. Gamma irradiation is mainly for disposable items. Various chemical agents are widely used even though they achieve high-level disinfection rather than sterilization. This article reviews various methods of endoscopic instrument sterilization with their advantages and drawbacks. If appropriate sterilization methods are adopted, then it not only will protect patients from procedure-related infections but prevent hypersensitive allergic reactions. It will also protect instruments from damage and increase its longevity.

  6. Endoscopically-controlled electrohydraulic intracorporeal shock wave lithotripsy (EISL) of salivary stones.

    PubMed

    Königsberger, R; Feyh, J; Goetz, A; Kastenbauer, E

    1993-02-01

    Twenty-nine patients with salivary stones were treated with the endoscopically-controlled electrohydraulic shock wave lithotripsy (EISL). This new minimally invasive treatment of sialolithiasis is performed under local anesthesia on an outpatient basis with little inconvenience to the patient. For endoscopy, a flexible fibroscope with an additional probe to generate shock waves is placed into the submandibular duct and advanced until the stone is identified. For shock wave-induced stone disintegration, the probe electrode must be placed 1 mm in front of the concrement. The shock waves are generated by a sparkover at the tip of the probe. By means of the endoscopically-controlled shock wave lithotripsy it was possible to achieve complete stone fragmentation in 20 out of 29 patients without serious side effects. In three patients, only partial stone fragmentation could be achieved due to the stone quality. Endoscopically-controlled electrohydraulic intracorporeal shock wave lithotripsy represents a novel minimally invasive therapy for endoscopically accessible salivary gland stones. The advantage in comparison to the endoscopically-controlled laser lithotripsy will be discussed.

  7. Endoscopic Submucosal Dissection: Indications and Application in Western Endoscopy Practice.

    PubMed

    Bourke, Michael J; Neuhaus, Horst; Bergman, Jacques J

    2018-05-01

    Endoscopic submucosal dissection was developed in Japan, early in this century, to provide a minimally invasive yet curative treatment for the large numbers of patients with early gastric cancer identified by the national screening program. Previously, the majority of these patients were treated surgically at substantial cost and with significant risk of short- and long-term morbidity. En-bloc excision of these early cancers, most with a limited risk of nodal metastasis, allowed complete staging of the tumor, stratification of the subsequent therapeutic approach, and potential cure. This transformative innovation changed the nature of endoscopic treatment for superficial mucosal neoplasia and, ultimately, for the first time allowed endoscopists to assert that the early cancer had been definitively cured. Subsequently, Western endoscopists have increasingly embraced the therapeutic possibilities offered by endoscopic submucosal dissection, but with some justifiable scientific caution. Here we provide an evidence-based critical appraisal of the role of endoscopic submucosal dissection in advanced endoscopic tissue resection. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  8. Endoscopic management of bile duct stones: residual bile duct stones after surgery, cholangitis, and "difficult stones".

    PubMed

    Karsenti, D

    2013-06-01

    Endoscopic treatment has become, according to the latest recommendations, the standard treatment for common bile duct stones (CBDS), although in certain situations, surgical clearance of the common duct at the time of laparoscopic cholecystectomy is still considered a possible alternative. The purpose of this article is not to compare endoscopic with surgical treatment of CBDS, but to describe the various techniques of endoscopic treatment, detailing their preferential indications and the various treatment options that must sometimes be considered when faced with "difficult calculi" of the CBD. The different techniques of lithotripsy and the role of biliary drainage with plastic or metallic stents will be detailed as well as papillary balloon dilatation and particularly the technique of sphincterotomy with macrodilatation of the sphincter of Oddi (SMSO), a recently described approach that has changed the strategy for endoscopic management of CBDS. Finally, the overall strategy for endoscopic management of CBDS, with description of different techniques, will be exposed. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  9. A high definition Mueller polarimetric endoscope for tissue characterisation

    NASA Astrophysics Data System (ADS)

    Qi, Ji; Elson, Daniel S.

    2016-05-01

    The contrast mechanism of medical endoscopy is mainly based on metrics of optical intensity and wavelength. As another fundamental property of light, polarization can not only reveal tissue scattering and absorption information from a different perspective, but can also provide insight into directional tissue birefringence properties to monitor pathological changes in collagen and elastin. Here we demonstrate a low cost wide field high definition Mueller polarimetric endoscope with minimal alterations to a rigid endoscope. We show that this novel endoscopic imaging modality is able to provide a number of image contrast mechanisms besides traditional unpolarized radiation intensity, including linear depolarization, circular depolarization, cross-polarization, directional birefringence and dichroism. This enhances tissue features of interest, and additionally reveals tissue micro-structure and composition, which is of central importance for tissue diagnosis and image guidance for surgery. The potential applications of the Mueller polarimetric endoscope include wide field early epithelial cancer diagnosis, surgical margin detection and energy-based tissue fusion monitoring, and could further benefit a wide range of endoscopic investigations through intra-operative guidance.

  10. A combination of modified transnasal endoscopic maxillectomy via transnasal prelacrimal recess approach with or without radiotherapy for selected sinonasal malignancies.

    PubMed

    He, Shuangba; Bakst, Richard L; Guo, Tao; Sun, Jingwu

    2015-10-01

    An external approach for resection of sinonasal tumors is associated with increased morbidity. Therefore, we employed a modified transnasal endoscopic maxillectomy combined with pre and/or postoperative radiotherapy for early stage maxillary carcinomas. It aims to evaluate our early experience with endoscopic resection of selected malignant sinonasal tumors. The medical and radiology records of patients who underwent endonasal endoscopic resection of malignant sinonasal tumors between 2008 and 2012 were retrospectively reviewed. Ten cases of selected malignant tumor were performed to resect by modified transnasal endoscopic maxillectomy. All the patients were without evidence of disease at a mean follow-up of 26.8 months. No major complications were recorded. The mean hospitalization stay was 6.6 days. In very carefully selected cases of malignant tumors, modified transnasal endoscopic maxillectomy is acceptable. The postoperative complication rate is low, cosmetic outcome is excellent and patients do not require a long hospitalization.

  11. Limits of the endoscopic transnasal transtubercular approach.

    PubMed

    Gellner, Verena; Tomazic, Peter V

    2018-06-01

    The endoscopic transnasal trans-sphenoidal transtubercular approach has become a standard alternative approach to neurosurgical transcranial routes for lesions of the anterior skull base in particular pathologies of the anterior tubercle, sphenoid plane, and midline lesions up to the interpeduncular cistern. For both the endoscopic and the transcranial approach indications must strictly be evaluated and tailored to the patients' morphology and condition. The purpose of this review was to evaluate the evidence in literature of the limitations of the endoscopic transtubercular approach. A PubMed/Medline search was conducted in January 2018 entering following keywords. Upon initial screening 7 papers were included in this review. There are several other papers describing the endoscopic transtubercular approach (ETTA). We tried to list the limitation factors according to the actual existing literature as cited. The main limiting factors are laterally extending lesions in relation to the optic canal and vascular encasement and/or unfavorable tumor tissue consistency. The ETTA is considered as a high level transnasal endoscopic extended skull base approach and requires excellent training, skills and experience.

  12. Cutting edge of endoscopic full-thickness resection for gastric tumor

    PubMed Central

    Maehata, Tadateru; Goto, Osamu; Takeuchi, Hiroya; Kitagawa, Yuko; Yahagi, Naohisa

    2015-01-01

    Recently, several studies have reported local full-thickness resection techniques using flexible endoscopy for gastric tumors, such as gastrointestinal stromal tumors, gastric carcinoid tumors, and early gastric cancer (EGC). These techniques have the advantage of allowing precise resection lines to be determined using intraluminal endoscopy. Thus, it is possible to minimize the resection area and subsequent deformity. Some of these methods include: (1) classical laparoscopic and endoscopic cooperative surgery (LECS); (2) inverted LECS; (3) combination of laparoscopic and endoscopic approaches to neoplasia with non-exposure technique; and (4) non-exposed endoscopic wall-inversion surgery. Furthermore, a recent prospective multicenter trial of the sentinel node navigation surgery (SNNS) for EGC has shown acceptable results in terms of sentinel node detection rate and the accuracy of nodal metastasis. Endoscopic full-thickness resection with SNNS is expected to become a treatment option that bridges the gap between endoscopic submucosal dissection and standard surgery for EGC. In the future, the indications for these procedures for gastric tumors could be expanded. PMID:26566427

  13. Anesthetic management of the SRS™ Endoscopic Stapling System for gastro-esophageal reflux disease.

    PubMed

    Topuz, Ufuk; Umutoglu, Tarik; Bakan, Mefkur; Ozturk, Erdogan

    2013-01-14

    The SRS(TM) Endoscopic Stapling System (Medigus, Tel Aviv, Israel) is a new tool capable of creating a totally endoscopic fundoplication, combined with an endoscope, endoscopic ultrasound and a surgical stapler. SRS(TM) endoscopic stapling for gastro-esophageal reflux disease is a minimally invasive, outpatient procedure, which requires general anesthesia with positive-pressure ventilation. Keeping the patient on positive end-expiratory pressure (PEEP) may minimize the pressure gradient between the esophagus and the mediastinum, as well as help to prevent air from leaking around the screws and causing pneumomediastinum. In addition, in patients with hiatal hernia, higher PEEP levels may be required to increase intra-thoracic pressure and to force the stomach to slide into the abdomen for ease of endoscopy. We advise smoother emergence from anesthesia, taking precautions for retching, postoperative nausea and vomiting (PONV), while coughing and gagging during extubation and PONV may affect the success of the procedure. Total intravenous anesthesia with propofol and remifentanil seems to be a good choice for these reasons.

  14. [Three-dimensional endoscopic endonasal study of skull base anatomy].

    PubMed

    Abarca-Olivas, Javier; Monjas-Cánovas, Irene; López-Álvarez, Beatriz; Lloret-García, Jaime; Sanchez-del Campo, Jose; Gras-Albert, Juan Ramon; Moreno-López, Pedro

    2014-01-01

    Training in dissection of the paranasal sinuses and the skull base is essential for anatomical understanding and correct surgical techniques. Three-dimensional (3D) visualisation of endoscopic skull base anatomy increases spatial orientation and allows depth perception. To show endoscopic skull base anatomy based on the 3D technique. We performed endoscopic dissection in cadaveric specimens fixed with formalin and with the Thiel technique, both prepared using intravascular injection of coloured material. Endonasal approaches were performed with conventional 2D endoscopes. Then we applied the 3D anaglyph technique to illustrate the pictures in 3D. The most important anatomical structures and landmarks of the sellar region under endonasal endoscopic vision are illustrated in 3D images. The skull base consists of complex bony and neurovascular structures. Experience with cadaver dissection is essential to understand complex anatomy and develop surgical skills. A 3D view constitutes a useful tool for understanding skull base anatomy. Copyright © 2012 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  15. A Review of Endoscopic Simulation: Current Evidence on Simulators and Curricula.

    PubMed

    King, Neil; Kunac, Anastasia; Merchant, Aziz M

    2016-01-01

    Upper and lower endoscopy is an important tool that is being utilized more frequently by general surgeons. Training in therapeutic endoscopic techniques has become a mandatory requirement for general surgery residency programs in the United States. The Fundamentals of Endoscopic Surgery has been developed to train and assess competency in these advanced techniques. Simulation has been shown to increase the skill and learning curve of trainees in other surgical disciplines. Several types of endoscopy simulators are commercially available; mechanical trainers, animal based, and virtual reality or computer-based simulators all have their benefits and limitations. However they have all been shown to improve trainee's endoscopic skills. Endoscopic simulators will play a critical role as part of a comprehensive curriculum designed to train the next generation of surgeons. We reviewed recent literature related to the various types of endoscopic simulators and their use in an educational curriculum, and discuss the relevant findings. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  16. Adjustable-Viewing-Angle Endoscopic Tool for Skull Base and Brain Surgery

    NASA Technical Reports Server (NTRS)

    Bae, Youngsam; Liao, Anna; Manohara, Harish; Shahinian, Hrayr

    2008-01-01

    The term Multi-Angle and Rear Viewing Endoscopic tooL (MARVEL) denotes an auxiliary endoscope, now undergoing development, that a surgeon would use in conjunction with a conventional endoscope to obtain additional perspective. The role of the MARVEL in endoscopic brain surgery would be similar to the role of a mouth mirror in dentistry. Such a tool is potentially useful for in-situ planetary geology applications for the close-up imaging of unexposed rock surfaces in cracks or those not in the direct line of sight. A conventional endoscope provides mostly a frontal view that is, a view along its longitudinal axis and, hence, along a straight line extending from an opening through which it is inserted. The MARVEL could be inserted through the same opening as that of the conventional endoscope, but could be adjusted to provide a view from almost any desired angle. The MARVEL camera image would be displayed, on the same monitor as that of the conventional endoscopic image, as an inset within the conventional endoscopic image. For example, while viewing a tumor from the front in the conventional endoscopic image, the surgeon could simultaneously view the tumor from the side or the rear in the MARVEL image, and could thereby gain additional visual cues that would aid in precise three-dimensional positioning of surgical tools to excise the tumor. Indeed, a side or rear view through the MARVEL could be essential in a case in which the object of surgical interest was not visible from the front. The conceptual design of the MARVEL exploits the surgeon s familiarity with endoscopic surgical tools. The MARVEL would include a miniature electronic camera and miniature radio transmitter mounted on the tip of a surgical tool derived from an endo-scissor (see figure). The inclusion of the radio transmitter would eliminate the need for wires, which could interfere with manipulation of this and other surgical tools. The handgrip of the tool would be connected to a linkage similar to that of an endo-scissor, but the linkage would be configured to enable adjustment of the camera angle instead of actuation of a scissor blade. It is envisioned that thicknesses of the tool shaft and the camera would be less than 4 mm, so that the camera-tipped tool could be swiftly inserted and withdrawn through a dime-size opening. Electronic cameras having dimensions of the order of millimeters are already commercially available, but their designs are not optimized for use in endoscopic brain surgery. The variety of potential endoscopic, thoracoscopic, and laparoscopic applications can be expected to increase as further development of electronic cameras yields further miniaturization and improvements in imaging performance.

  17. Assessment on Experimental Bacterial Biofilms and in Clinical Practice of the Efficacy of Sampling Solutions for Microbiological Testing of Endoscopes

    PubMed Central

    Aumeran, C.; Thibert, E.; Chapelle, F. A.; Hennequin, C.; Lesens, O.

    2012-01-01

    Opinions differ on the value of microbiological testing of endoscopes, which varies according to the technique used. We compared the efficacy on bacterial biofilms of sampling solutions used for the surveillance of the contamination of endoscope channels. To compare efficacy, we used an experimental model of a 48-h Pseudomonas biofilm grown on endoscope internal tubing. Sampling of this experimental biofilm was performed with a Tween 80-lecithin-based solution, saline, and sterile water. We also performed a randomized prospective study during routine clinical practice in our hospital sampling randomly with two different solutions the endoscopes after reprocessing. Biofilm recovery expressed as a logarithmic ratio of bacteria recovered on bacteria initially present in biofilm was significantly more effective with the Tween 80-lecithin-based solution than with saline solution (P = 0.002) and sterile water (P = 0.002). There was no significant difference between saline and sterile water. In the randomized clinical study, the rates of endoscopes that were contaminated with the Tween 80-lecithin-based sampling solution and the saline were 8/25 and 1/25, respectively (P = 0.02), and the mean numbers of bacteria recovered were 281 and 19 CFU/100 ml (P = 0.001), respectively. In conclusion, the efficiency and therefore the value of the monitoring of endoscope reprocessing by microbiological cultures is dependent on the sampling solutions used. A sampling solution with a tensioactive action is more efficient than saline in detecting biofilm contamination of endoscopes. PMID:22170930

  18. Use of prototype two-channel endoscope with elevator enables larger lift-and-snare endoscopic mucosal resection in a porcine model

    PubMed Central

    Atkinson, Matthew; Chukwumah, Chike; Marks, Jeffrey; Chak, Amitabh

    2014-01-01

    Background: Flat and depressed lesions are becoming increasingly recognized in the esophagus, stomach, and colon. Various techniques have been described for endoscopic mucosal resection (EMR) of these lesions. Aims: To evaluate the efficacy of lift-grasp-cut EMR using a prototype dual-channel forward-viewing endoscope with an instrument elevator in one accessory channel (dual-channel elevator scope) as compared to standard dual-channel endoscopes. Methods: EMR was performed using a lift-grasp-cut technique on normal flat rectosigmoid or gastric mucosa in live porcine models after submucosal injection of 4 mL of saline using a dual-channel elevator scope or a standard dual-channel endoscope. With the dual-channel elevator scope, the elevator was used to attain further lifting of the mucosa. The primary endpoint was size of the EMR specimen and the secondary endpoint was number of complications. Results: Twelve experiments were performed (six gastric and six colonic). Mean specimen diameter was 2.27 cm with the dual-channel elevator scope and 1.34 cm with the dual-channel endoscope (P = 0.018). Two colonic perforations occurred with the dual-channel endoscope, vs no complications with the dual-channel elevator scope. Conclusions: The increased lift of the mucosal epithelium, through use of the dual-channel elevator scope, allows for larger EMR when using a lift-grasp-cut technique. Noting the thin nature of the porcine colonic wall, use of the elevator may also make this technique safer. PMID:24760237

  19. Experimental evaluation of an automated endoscope reprocessor with in situ generation of peracetic acid for disinfection of semicritical devices.

    PubMed

    Sattar, Syed A; Kibbee, Richard J; Tetro, Jason A; Rook, Tony A

    2006-11-01

    To evaluate the effectiveness of a high-level disinfection solution generated inside an endoscope processing system for decontaminating external and internal surfaces of experimentally contaminated heat-sensitive medical devices. The American Society for Testing and Materials Simulated-Use Test protocol (E1837-02), which incorporates a soil load in each inoculum, was used to evaluate the efficacy of the system when processing 4 common types of endoscopes contaminated separately with 5 types of nosocomial pathogens: Pseudomonas aeruginosa (ATCC 15442), spores of Clostridium difficile (ATCC 9689), a glutaraldehyde-resistant strain of Mycobacterium chelonae, a vancomycin-resistant strain of Enterococcus faecalis, and a methicillin-resistant strain of Staphylococcus aureus. Rinse solution samples from channels and from surfaces of the processed endoscopes were tested for any microbicidal residues. For all organisms tested, the baseline level of contamination of the endoscopes ranged from 5 log(10) to greater than 7 log(10) at each external surface site and internal channel. All tests showed reductions in viability of the test organisms to undetectable levels. All rinse solution samples from external and internal sites of the endoscopes proved to be free of any residual microbicidal activity. The endoscope reprocessor, with its processor-generated high-level disinfection solution, successfully reduced the numbers of selected, clinically relevant pathogens to undetectable levels both in the channels and on the outside surfaces of the 4 representative endoscopes tested in this study.

  20. Real-time ultrasound-guided endoscopic surgery for putaminal hemorrhage.

    PubMed

    Sadahiro, Hirokazu; Nomura, Sadahiro; Goto, Hisaharu; Sugimoto, Kazutaka; Inamura, Akinori; Fujiyama, Yuichi; Yamane, Akiko; Oku, Takayuki; Shinoyama, Mizuya; Suzuki, Michiyasu

    2015-11-01

    Endoscopic surgery plays a significant role in the treatment of intracerebral hemorrhage. However, the residual hematoma cannot be measured intraoperatively from the endoscopic view, and it is difficult to determine the precise location of the endoscope within the hematoma cavity. The authors attempted to develop real-time ultrasound-guided endoscopic surgery using a bur-hole-type probe. From November 2012 to March 2014, patients with hypertensive putaminal hemorrhage who underwent endoscopic hematoma removal were enrolled in this study. Real-time ultrasound guidance was performed with a bur-hole-type probe that was advanced via a second bur hole, which was placed in the temporal region. Ultrasound was used to guide insertion of the endoscope sheath as well as to provide information regarding the location of the hematoma during surgical evacuation. Finally, the cavity was irrigated with artificial cerebrospinal fluid and was observed as a low-echoic space, which facilitated detection of residual hematoma. Ten patients with putaminal hemorrhage>30 cm3 were included in this study. Their mean age (±SD) was 60.9±8.6 years, and the mean preoperative hematoma volume was 65.2±37.1 cm3. The mean percentage of hematoma that was evacuated was 96%±3%. None of the patients exhibited rebleeding after surgery. This navigation method was effective in demonstrating both the real-time location of the endoscope and real-time viewing of the residual hematoma. Use of ultrasound guidance minimized the occurrence of brain injury due to hematoma evacuation.

  1. Endoscopic versus transcranial procurement of allograft tympano-ossicular systems: a prospective double-blind randomized controlled audit.

    PubMed

    Caremans, Jeroen; Hamans, Evert; Muylle, Ludo; Van de Heyning, Paul; Van Rompaey, Vincent

    2016-06-01

    Allograft tympano-ossicular systems (ATOS) have proven their use over many decades in tympanoplasty and reconstruction after resection of cholesteatoma. The transcranial bone plug technique has been used in the past 50 years to procure en bloc ATOS (tympanic membrane with malleus, incus and stapes attached). Recently, our group reported the feasibility of the endoscopic procurement technique. The aim of this study was to assess whether clinical outcome is equivalent in ATOS acquired by using the endoscopic procurement technique compared to ATOS acquired by using the transcranial technique. A double-blind randomized controlled audit was performed in a tertiary referral center in patients that underwent allograft tympanoplasty because of chronic otitis media with and without cholesteatoma. Allograft epithelialisation was evaluated at the short-term postoperative visit by microscopic examination. Failures were reported if reperforation was observed. Fifty patients underwent allograft tympanoplasty: 34 received endoscopically procured ATOS and 16 received transcranially procured ATOS. One failed case was observed, in the endoscopic procurement group. We did not observe a statistically significant difference between the two groups in failure rate. This study demonstrates equivalence of the clinical outcome of allograft tympanoplasty using either endoscopic or transcranial procured ATOS and therefore indicates that the endoscopic technique can be considered the new standard procurement technique. Especially because the endoscopic procurement technique has several advantages compared to the former transcranial procurement technique: it avoids risk of prion transmission and it is faster while lacking any noticeable incision.

  2. Towards automated visual flexible endoscope navigation.

    PubMed

    van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J

    2013-10-01

    The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.

  3. Endoscopic papillectomy: indications, techniques, and results.

    PubMed

    De Palma, Giovanni D

    2014-02-14

    Endoscopic papillectomy (EP) is currently accepted as a viable alternative therapy to surgery in sporadic ampullary adenoma and has been reported to have high success and low recurrence rates. At present, the indications for EP are not yet fully established. The accepted criteria for EP include size (up to 5 cm), no evidence of intraductal growth, and no evidence of malignancy on endoscopic findings (ulceration, friability, and spontaneous bleeding). Endoscopic ultrasound (EUS) is the imaging modality of choice for local T staging in ampullary neoplasms. Data reported in the literature have revealed that linear EUS is superior to helical computed tomography in the preoperative assessment of tumor size, detection of regional nodal metastases and detection of major vascular invasion. Endoscopic ampullectomy is performed using a standard duodenoscope in a similar manner to snare polypectomy of a mucosal lesion. There is no standardization of the equipment or technique and broad EP methods are described. Endoscopic ampullectomy is considered a ''high-risk'' procedure due to complications. Complications of endoscopic papillectomy can be classified as early (pancreatitis, bleeding, perforation, and cholangitis) and late (papillary stenosis) complications. The appropriate use of stenting after ampullectomy may prevent post-procedural pancreatitis and papillary stenosis. Tumor recurrence of benign lesions occurs in up to 20% of patients and depends on tumor size, final histology, presence of intraductal tumor, coexisting familial adenomatous polyposis (FAP), and the expertise of the endoscopist. Recurrent lesions are usually benign and most can be retreated endoscopically.

  4. Ultrathin endoscope flexibility can predict discomfort associated with unsedated transnasal esophagogastroduodenoscopy

    PubMed Central

    Ono, Satoshi; Niimi, Keiko; Fujishiro, Mitsuhiro; Nakao, Tomoko; Suzuki, Kazushi; Ohike, Yumiko; Kodashima, Shinya; Yamamichi, Nobutake; Yamazaki, Tsutomu; Koike, Kazuhiko

    2013-01-01

    AIM: To evaluate the effects of choice of insertion route and ultrathin endoscope types. METHODS: This prospective study (January-June 2012) included 882 consecutive patients who underwent annual health checkups. Transnasal esophagogastroduodenoscopy (EGD) was performed in 503 patients and transoral EGD in 235 patients using six types of ultrathin endoscopes. Patients were given a choice of insertion route, either transoral or transnasal, prior to EGD examination. For transoral insertion, the endoscope was equipped with a thin-type mouthpiece and tongue depressor. Conscious sedation was not used for any patient. EGD-associated discomfort was assessed using a visual analog scale (VAS; no discomfort 0- maximum discomfort 10). RESULTS: Rates of preference for transnasal insertion were significantly higher in male (male/female 299/204 vs 118/117) and younger patients (56.8 ± 11.2 years vs 61.3 ± 13.0 years), although no significant difference was found in VAS scores between transoral and transnasal insertion (3.9 ± 2.3 vs 4.1 ± 2.5). Multivariate analysis revealed that gender, age, operator, and endoscope were independent significant predictors of VAS for transnasal insertion, although gender, age, and endoscope were those for transoral insertion. Further analysis revealed only the endoscopic flexibility index (EFI) as an independent significant predictor of VAS for transnasal insertion. Both EFI and tip diameter were independent significant predictors of VAS for transoral insertion. CONCLUSION: Flexibility of ultrathin endoscopes can be a predictor of EGD-associated discomfort, especially in transnasal insertion. PMID:23858379

  5. The Implications of Endoscopic Ulcer in Early Gastric Cancer: Can We Predict Clinical Behaviors from Endoscopy?

    PubMed

    Lee, Yoo Jin; Kim, Jie-Hyun; Park, Jae Jun; Youn, Young Hoon; Park, Hyojin; Kim, Jong Won; Choi, Seung Ho; Noh, Sung Hoon

    2016-01-01

    The presence of ulcer in early gastric cancer (EGC) is important for the feasibility of endoscopic resection, only a few studies have examined the clinicopathological implications of endoscopic ulcer in EGC. To determine the role of endoscopic ulcer as a predictor of clinical behaviors in EGC. Data of 3,270 patients with EGC who underwent surgery between January 2005 and December 2012 were reviewed. Clinicopathological characteristics were analyzed in relation to the presence and stage of ulcer in EGC. Based on endoscopic findings, the stage of ulcer was categorized as active, healing, or scar. Logistic regression analysis was performed to analyze factors associated with lymph node metastasis (LNM). 2,343 (71.7%) patients had endoscopic findings of ulceration in EGC. Submucosal (SM) invasion, LNM, lymphovascular invasion (LVI), perineural invasion, and undifferentiated-type histology were significantly higher in ulcerative than non-ulcerative EGC. Comparison across different stages of ulcer revealed that SM invasion, LNM, and LVI were significantly associated with the active stage, and that these features exhibited significant stage-based differences, being most common at the active stage, and least common at the scar stage. The presence of endoscopic ulcer and active status of the ulcer were identified as independent risk factors for LNM. Ulcerative EGC detected by endoscopy exhibited more aggressive behaviors than non-ulcerative EGC. Additionally, the endoscopic stage of ulcer may predict the clinicopathological behaviors of EGC. Therefore, the appearance of ulcers should be carefully evaluated to determine an adequate treatment strategy for EGC.

  6. Development and validation of an algorithm to complete colonoscopy using standard endoscopes in patients with prior incomplete colonoscopy

    PubMed Central

    Rogers, Melinda C.; Gawron, Andrew; Grande, David; Keswani, Rajesh N.

    2017-01-01

    Background and study aims  Incomplete colonoscopy may occur as a result of colon angulation (adhesions or diverticulosis), endoscope looping, or both. Specialty endoscopes/devices have been shown to successfully complete prior incomplete colonoscopies, but may not be widely available. Radiographic or other image-based evaluations have been shown to be effective but may miss small or flat lesions, and colonoscopy is often still indicated if a large lesion is identified. The purpose of this study was to develop and validate an algorithm to determine the optimum endoscope to ensure completion of the examination in patients with prior incomplete colonoscopy. Patients and methods  This was a prospective cohort study of 175 patients with prior incomplete colonoscopy who were referred to a single endoscopist at a single academic medical center over a 3-year period from 2012 through 2015. Colonoscopy outcomes from the initial 50 patients were used to develop an algorithm to determine the optimal standard endoscope and technique to achieve cecal intubation. The algorithm was validated on the subsequent 125 patients. Results  The overall repeat colonoscopy success rate using a standard endoscope was 94 %. The initial standard endoscope specified by the algorithm was used and completed the colonoscopy in 90 % of patients. Conclusions  This study identifies an effective strategy for completing colonoscopy in patients with prior incomplete examination, using widely available standard endoscopes and an algorithm based on patient characteristics and reasons for prior incomplete colonoscopy. PMID:28924595

  7. Esophagus: Endoscopic therapy for flat, dysplastic Barrett esophagus.

    PubMed

    Peery, Anne F; Shaheen, Nicholas J

    2011-04-01

    Both stepwise radical endoscopic resection (SRER) and radiofrequency ablation (RFA) are effective endoscopic strategies for the treatment of patients with flat, dysplastic Barrett esophagus. Findings from a randomized, controlled trial indicate that the two treatments have similar efficacy, but considerably more complications are associated with SRER compared with RFA.

  8. Basics of robotics and manipulators in endoscopic surgery.

    PubMed

    Rininsland, H H

    1993-06-01

    The experience with sophisticated remote handling systems for nuclear operations in inaccessible rooms can to a large extent be transferred to the development of robotics and telemanipulators for endoscopic surgery. A telemanipulator system is described consisting of manipulator, endeffector and tools, 3-D video-endoscope, sensors, intelligent control system, modeling and graphic simulation and man-machine interfaces as the main components or subsystems. Such a telemanipulator seems to be medically worthwhile and technically feasible, but needs a lot of effort from different scientific disciplines to become a safe and reliable instrument for future endoscopic surgery.

  9. Endoscopic management of ingested foreign bodies and food impactions.

    PubMed

    Malick, K Jane

    2013-01-01

    Endoscopy plays a major role in the management of foreign bodies and food impactions. Because of their frequent occurrence and potential for complications, it is important for the gastroenterology nurse and associate to gain an understanding of the incidence, diagnosis, and management of patients who present with ingested foreign bodies or food impaction. This article summarizes the clinical approach to patient: assessment, preparation for endoscopic procedure, preparation of endoscopic accessories, and follow-up care. Finally, an interesting case presentation highlights key components of caring for patients requiring endoscopic intervention.

  10. Fluoroscopy-Guided Endoscopic Removal of Foreign Bodies.

    PubMed

    Kim, Junhwan; Ahn, Ji Yong; So, Seol; Lee, Mingee; Oh, Kyunghwan; Jung, Hwoon-Yong

    2017-03-01

    In most cases of ingested foreign bodies, endoscopy is the first treatment of choice. Moreover, emergency endoscopic removal is required for sharp and pointed foreign bodies such as animal or fish bones, food boluses, and button batteries due to the increased risks of perforation, obstruction, and bleeding. Here, we presented two cases that needed emergency endoscopic removal of foreign bodies without sufficient fasting time. Foreign bodies could not be visualized by endoscopy due to food residue; therefore, fluoroscopic imaging was utilized for endoscopic removal of foreign bodies in both cases.

  11. Endoscopic Management of an Intramural Sinus Leak After Per- Oral Endoscopic Myotomy

    PubMed Central

    Al Taii, Haider; Confer, Bradley; Gabbard, Scott; Kroh, Matthew; Jang, Sunguk; Rodriguez, John; Parsi, Mansour A.; Vargo, John J.; Ponsky, Jeffrey

    2016-01-01

    Per-oral endoscopic myotomy (POEM) was developed less than a decade ago for the treatment of achalasia. Its minimally invasive approach and the favorable short-term outcome have led to rapid adoption of the technique throughout the world. As with any new technique, there will be adverse events, and it is important that effective treatments for these adverse events be discussed. We present a case of successful endoscopic management of an intramural sinus leak after a POEM procedure using tandem fully covered esophageal stents. PMID:27921057

  12. In vivo endoscopic optical coherence tomography by use of a rotational microelectromechanical system probe

    NASA Astrophysics Data System (ADS)

    Tran, Peter H.; Mukai, David S.; Brenner, Matthew; Chen, Zhongping

    2004-06-01

    A novel endoscopic optical coherence tomography probe was designed and constructed with a 1.9-mm microelectromechanical system (MEMS) motor. The new MEMS endoscopic probe design eliminates the need to couple the rotational energy from the proximal to the distal end of the probe. Furthermore, the endoscopic probe's sheath and fiber have the advantages of having a much smaller diameter and being more flexible than traditional endoscopes since no reinforcement is needed to couple the rotational torque. At the distal end, a prism mounted on a micromotor deflects the light rays to create a transverse circular-scanning pathway. Because our MEMS scanner does not require the coupling of a rotational single-mode fiber, a high scanning speed is possible while eliminating unstable optical signals caused by nonuniform coupling.

  13. Design of the computerized 3D endoscopic imaging system for delicate endoscopic surgery.

    PubMed

    Song, Chul-Gyu; Kang, Jin U

    2011-02-01

    This paper describes a 3D endoscopic video system designed to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. In a comparison of the polarized and conventional electric shutter-type stereo imaging systems, the former was found to be superior in terms of both accuracy and speed for suturing and for the loop pass test. Among the groups performing loop passing and suturing, there was no significant difference in the task performance between the 2D and 3D modes, however, suturing was performed 15% (p < 0.05) faster in 3D mode by both groups. The results of our experiments show that the proposed 3D endoscopic system has a sufficiently wide viewing angle and zone for multi-viewing.

  14. Calibration procedures of the Tore-Supra infrared endoscopes

    NASA Astrophysics Data System (ADS)

    Desgranges, C.; Jouve, M.; Balorin, C.; Reichle, R.; Firdaouss, M.; Lipa, M.; Chantant, M.; Gardarein, J. L.; Saille, A.; Loarer, T.

    2018-01-01

    Five endoscopes equipped with infrared cameras working in the medium infrared range (3-5 μm) are installed on the controlled thermonuclear fusion research device Tore-Supra. These endoscopes aim at monitoring the plasma facing components surface temperature to prevent their overheating. Signals delivered by infrared cameras through endoscopes are analysed and used on the one hand through a real time feedback control loop acting on the heating systems of the plasma to decrease plasma facing components surface temperatures when necessary, on the other hand for physics studies such as determination of the incoming heat flux . To ensure these two roles a very accurate knowledge of the absolute surface temperatures is mandatory. Consequently the infrared endoscopes must be calibrated through a very careful procedure. This means determining their transmission coefficients which is a delicate operation. Methods to calibrate infrared endoscopes during the shutdown period of the Tore-Supra machine will be presented. As they do not allow determining the possible transmittances evolution during operation an in-situ method is presented. It permits the validation of the calibration performed in laboratory as well as the monitoring of their evolution during machine operation. This is possible by the use of the endoscope shutter and a dedicated plasma scenario developed to heat it. Possible improvements of this method are briefly evoked.

  15. Nonampullary duodenal adenoma: Current understanding of its diagnosis, pathogenesis, and clinical management

    PubMed Central

    Lim, Chul-Hyun; Cho, Young-Seok

    2016-01-01

    Nonampullary duodenal adenomas are relatively common in familial adenomatous polyposis (FAP), but nonampullary sporadic duodenal adenomas (SDAs) are rare. Emerging evidence shows that duodenal adenomas, regardless of their anatomic location and whether they are sporadic or FAP-related, share morphologic and molecular features with colorectal adenomas. The available data suggest that duodenal adenomas develop to duodenal adenocarcinomas via similar mechanisms. The optimal approach for management of duodenal adenomas remains to be determined. The techniques for endoscopic resection of duodenal adenoma include snare polypectomy, endoscopic mucosal resection (EMR), endoscopic submucosal dissection (ESD), and argon plasma coagulation ablation. EMR may facilitate removal of large duodenal polyps. Although several studies have reported cases of successful ESD for duodenal adenomas, the procedure is technically difficult to perform safely because of the anatomical properties of the duodenum. Although current clinical practice recommends endoscopic resection of all large duodenal adenomas in patients with FAP, endoscopic treatment is usually insufficient to guarantee a polyp-free duodenum. Surgery is indicated for FAP patients with severe polyposis or nonampullary SDAs or FAP-related polyps not amenable to endoscopic resection. Further studies are needed to develop newer endoscopic techniques to guide diagnostic and therapeutic decisions for future management of nonampullary duodenal adenomas. PMID:26811631

  16. Endoscopic management of gastrointestinal perforations, leaks and fistulas

    PubMed Central

    Rogalski, Pawel; Daniluk, Jaroslaw; Baniukiewicz, Andrzej; Wroblewski, Eugeniusz; Dabrowski, Andrzej

    2015-01-01

    Gastrointestinal perforations, leaks and fistulas may be serious and life-threatening. The increasing number of endoscopic procedures with a high risk of perforation and the increasing incidence of leakage associated with bariatric operations call for a minimally invasive treatment for these complications. The therapeutic approach can vary greatly depending on the size, location, and timing of gastrointestinal wall defect recognition. Some asymptomatic patients can be treated conservatively, while patients with septic symptoms or cardio-pulmonary insufficiency may require intensive care and urgent surgical treatment. However, most gastrointestinal wall defects can be satisfactorily treated by endoscopy. Although the initial endoscopic closure rates of chronic fistulas is very high, the long-term results of these treatments remain a clinical problem. The efficacy of endoscopic therapy depends on several factors and the best mode of treatment will depend on a precise localization of the site, the extent of the leak and the endoscopic appearance of the lesion. Many endoscopic tools for effective closure of gastrointestinal wall defects are currently available. In this review, we summarized the basic principles of the management of acute iatrogenic perforations, as well as of postoperative leaks and chronic fistulas of the gastrointestinal tract. We also described the effectiveness of various endoscopic methods based on current research and our experience. PMID:26457014

  17. Postoperative haemorrhage following transurethral resection of the prostate (TURP) and photoselective vaporisation of the prostate (PVP)

    PubMed Central

    Lynch, Mark; Sriprasad, Seshadri; Subramonian, Kesavapillai; Thompson, Peter

    2010-01-01

    INTRODUCTION Intractable haemorrhage after endoscopic surgery, including transurethral resection of the prostate (TURP) and photoselective vaporisation of the prostate (PVP), is uncommon but a significant and life-threatening problem. The knowledge and technical experience to deal with this complication may not be wide-spread among urologists and trainees. We describe our series of TURPs and PVPs and the incidence of postoperative bleeding requiring intervention. PATIENTS AND METHODS We retrospectively reviewed 437 TURPs and 590 PVPs over 3 years in our institution. We describe the conservative, endoscopic and open prostatic packing techniques used for patients who experienced postoperative bleeding. RESULTS Of 437 TURPs, 19 required endoscopic intervention for postoperative bleeding. Of 590 PVPs, two patients were successfully managed endoscopically for delayed haemorrhage at 7 and 13 days post-surgery, respectively. In one TURP and one PVP patient, endoscopic management was insufficient to control postoperative haemorrhage and open exploration and packing of the prostatic cavity was performed. CONCLUSIONS Significant bleeding after endoscopic prostatic surgery is still a potentially life-threatening complication. Prophylactic measures have been employed to reduce peri-operative bleeding but persistent bleeding post-endoscopic prostatic surgery should be treated promptly to prevent the risk of rapid deterioration. We demonstrated that the technique of open prostate packing may be life-saving. PMID:20522311

  18. Endoscopic approach for management of biliary strictures in liver transplant recipients: A systematic review and meta-analysis

    PubMed Central

    Aparício, Dayse Pereira da Silva; Otoch, José Pinhata; Montero, Edna Frasson de Souza; Artifon, Everson Luiz de Almeida

    2016-01-01

    The most common biliary complication after liver transplantation is anastomotic stricture (AS) and it can occur isolated or in combination with other complications. Liver graft from a cadaveric donor or a living donor has an influence on the incidence of biliary strictures as well as on the response to endoscopic treatment. Endoscopic treatment using balloon dilation and insertion of biliary stents by endoscopic retrograde cholangiopancreatography (ERCP) is the initial approach to these complications. Aim The aim of this article is to compare different endoscopic techniques to treat post-liver transplantation biliary strictures. Methods The search was carried out on MEDLINE, EMBASE, Scielo-LILACS and Cochrane Library databases through June 2015. A total of 1100 articles were retrieved. Ten clinical trials were analyzed, and seven were included in the meta-analysis. Conclusions The endoscopic treatment of AS was equally effective when compared the use of fully covered self-expandable metal stents (FCSEMS) vs. plastic stents, but the use of FCSEMS was associated with a lower complication risk. The treatment of AS with balloon dilation or balloon dilation associated with plastic stents presented similar results. Deceased donor liver transplantation reduced the risk of biliary stenosis and the endoscopic treatment in these patients was more effective when compared with Living donor liver transplantation. PMID:29026597

  19. Tokyo Guidelines 2018: management strategies for gallbladder drainage in patients with acute cholecystitis (with videos).

    PubMed

    Mori, Yasuhisa; Itoi, Takao; Baron, Todd H; Takada, Tadahiro; Strasberg, Steven M; Pitt, Henry A; Ukai, Tomohiko; Shikata, Satoru; Noguchi, Yoshinori; Teoh, Anthony Yuen Bun; Kim, Myung-Hwan; Asbun, Horacio J; Endo, Itaru; Yokoe, Masamichi; Miura, Fumihiko; Okamoto, Kohji; Suzuki, Kenji; Umezawa, Akiko; Iwashita, Yukio; Hibi, Taizo; Wakabayashi, Go; Han, Ho-Seong; Yoon, Yoo-Seok; Choi, In-Seok; Hwang, Tsann-Long; Chen, Miin-Fu; Garden, O James; Singh, Harjit; Liau, Kui-Hin; Huang, Wayne Shih-Wei; Gouma, Dirk J; Belli, Giulio; Dervenis, Christos; de Santibañes, Eduardo; Giménez, Mariano Eduardo; Windsor, John A; Lau, Wan Yee; Cherqui, Daniel; Jagannath, Palepu; Supe, Avinash Nivritti; Liu, Keng-Hao; Su, Cheng-Hsi; Deziel, Daniel J; Chen, Xiao-Ping; Fan, Sheung Tat; Ker, Chen-Guo; Jonas, Eduard; Padbury, Robert; Mukai, Shuntaro; Honda, Goro; Sugioka, Atsushi; Asai, Koji; Higuchi, Ryota; Wada, Keita; Yoshida, Masahiro; Mayumi, Toshihiko; Hirata, Koichi; Sumiyama, Yoshinobu; Inui, Kazuo; Yamamoto, Masakazu

    2018-01-01

    Since the publication of the Tokyo Guidelines in 2007 and their revision in 2013, appropriate management for acute cholecystitis has been more clearly established. Since the last revision, several manuscripts, especially for alternative endoscopic techniques, have been reported; therefore, additional evaluation and refinement of the 2013 Guidelines is required. We describe a standard drainage method for surgically high-risk patients with acute cholecystitis and the latest developed endoscopic gallbladder drainage techniques described in the updated Tokyo Guidelines 2018 (TG18). Our study confirmed that percutaneous transhepatic gallbladder drainage should be considered the first alternative to surgical intervention in surgically high-risk patients with acute cholecystitis. Also, endoscopic transpapillary gallbladder drainage or endoscopic ultrasound-guided gallbladder drainage can be considered in high-volume institutes by skilled endoscopists. In the endoscopic transpapillary approach, either endoscopic naso-gallbladder drainage or gallbladder stenting can be considered for gallbladder drainage. We also introduce special techniques and the latest outcomes of endoscopic ultrasound-guided gallbladder drainage studies. Free full articles and mobile app of TG18 are available at: http://www.jshbps.jp/modules/en/index.php?content_id=47. Related clinical questions and references are also included. © 2017 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  20. Duct Diameter and Size of Stones Predict Successful Extracorporeal Shock Wave Lithotripsy and Endoscopic Clearance in Patients With Chronic Pancreatitis and Pancreaticolithiasis.

    PubMed

    Lapp, Robert T; Wolf, J Stuart; Faerber, Gary J; Roberts, William W; McCarthy, Sean T; Anderson, Michelle A; Wamsteker, Erik-Jan; Elta, Grace H; Scheiman, James M; Kwon, Richard S

    2016-09-01

    The need for endoscopic therapy before extracorporeal shock wave lithotripsy (SWL) to facilitate pancreatic duct stone removal is unclear. Predictive factors associated with successful fragmentation and subsequent complete duct clearance are variable. We hypothesize pancreatic duct strictures and large stones, but not pre-SWL endotherapy, correlate with successful fragmentation and complete duct clearance. A retrospective cohort study of patients with pancreaticolithiasis who underwent SWL and endoscopic retrograde cholangiopancreatography between January 2009 and June 2014 was evaluated. Thirty-seven patients were treated. Technical success (TS) of fragmentation was achieved in 22 patients (60%). Technical success was associated with fewer stones and SWL sessions and smaller stone and duct size. By multivariate logistic regression, only duct dilation was associated with TS. Endoscopic success of complete duct clearance was achieved in 29 patients (80%). Endoscopic success was more frequent with stones 12 mm or less and with successful TS. By multivariate logistic regression, stones greater than 12 mm were associated with endoscopic failure. Pre-SWL endotherapy does not affect stone fragmentation. Patients with a dilated duct (>8 mm) and pancreatic stones 12 mm or greater were associated with unsuccessful TS and endoscopic success, respectively, and may benefit from early referral for surgical decompression.

  1. Forward-viewing endoscopic ultrasound-guided NOTES interventions: A study on peritoneoscopic potential

    PubMed Central

    Jeong, Seung Uk; Aizan, Hassanuddin; Song, Tae Jun; Seo, Dong Wan; Kim, Su-Hui; Park, Do Hyun; Lee, Sang Soo; Lee, Sung Koo; Kim, Myung-Hwan

    2013-01-01

    AIM: To evaluate the feasibility of diagnostic and therapeutic transgastric (TG) peritoneoscopic interventions with a forward-viewing endoscopic ultrasound (FV-EUS). METHODS: This prospective endoscopic experimental study used an animal model. Combined TG peritoneoscopic interventions and EUS examination of the intra-abdominal organs were performed using an FV-EUS on 10 animal models (1 porcine and 9 canine). The procedures carried out include EUS evaluation and endoscopic biopsy of intraperitoneal organs, EUS-guided fine needle aspiration (EUS-FNA), EUS-guided radiofrequency ablation (EUS-RFA), and argon plasma coagulation (APC) for hemostatic control. The animals were kept alive for 7 d, and then necropsy was performed to evaluate results and complications. RESULTS: In all 10 animals, TG peritoneoscopy, followed by endoscopic biopsy for the liver, spleen, abdominal wall, and omentum, was performed successfully. APC helped control minor bleeding. Visualization of intra-abdominal solid organs with real-time EUS was accomplished with ease. Intraperitoneal EUS-FNA was successfully performed on the liver, spleen, and kidney. Similarly, a successful outcome was achieved with EUS-RFA of the hepatic parenchyma. No adverse events were recorded during the study. CONCLUSION: Peritoneoscopic natural orifice transluminal endoscopic surgery (NOTES) interventions through FV-EUS were feasible in providing evaluation and performing endoscopic procedures. It promises potential as a platform for future EUS-based NOTES. PMID:24222961

  2. Safe procedure in endoscopic submucosal dissection for colorectal tumors focused on preventing complications

    PubMed Central

    Yoshida, Naohisa; Yagi, Nobuaki; Naito, Yuji; Yoshikawa, Toshikazu

    2010-01-01

    Endoscopic submucosal dissection (ESD) is efficient for en bloc resection of large colorectal tumors. However, it has several technical difficulties, because the wall of the colon is thin and due to the winding nature of the colon. The main complications of ESD comprise postoperative perforation and hemorrhage, similar to endoscopic mucosal resection (EMR). In particular, the rate of perforation in ESD is higher than that in EMR. Perforation of the colon can cause fatal peritonitis. Endoscopic clipping is reported to be an efficient therapy for perforation. Most cases with perforation are treated conservatively without urgent surgical intervention. However, the rate of postoperative hemorrhage in ESD is similar to that in EMR. Endoscopic therapy including endoscopic clipping is performed and most of the cases are treated conservatively without blood transfusion. In blood examination, some degree of inflammation is detected after ESD. For the standardization of ESD, it is most important to decrease the rate of perforation. Adopting a safe strategy for ESD and a suitable choice of knife are both important ways of preventing perforation. Moreover, appropriate training and increasing experience can improve the endoscopic technique and can decrease the rate of perforation. In this review, we describe safe procedures in ESD to prevent complications, the complications of ESD and their management. PMID:20379999

  3. Capsular locomotive microrobot for gastrointestinal tract.

    PubMed

    Park, Sukho; Park, Hyunjun; Park, Sungjin; Jee, Changyeol; Kim, Jinseok; Kim, Byungkyu

    2006-01-01

    Diagnosis using a flexible endoscope in gastro-intestinal tract becomes very important. In addition, the endoscope is a basic tool of diagnosis and treatment for digestive organ. However, the operation of endoscope is very labor intensive work and gives patients some pains. Therefore, the capsule-type endoscope is developed for the diagnosis of digestive organs. For its conveniences for diagnosis, the capsule endoscope comes into the spotlight. However, it is passively moved by the peristaltic waves of gastro-intestinal tract and thus has some limitations for doctor to get the image of the organ and to diagnose more thoroughly. In order to solve these problems, therefore, a locomotive mechanism of capsule endoscopes has being developed. For the locomotion in the gastro-intestinal tract, our proposed capsule-type microrobot has synchronized multiple legs that are actuated by a linear actuator and two mobile cylinders inside of the capsule. For the feasibility test of the proposed locomotive mechanism, a series of in-vitro experiments using small intestine without incision were carried out. In addition, in-vivo animal tests under a general anesthesia are also executed. From the experimental results, we conclude that the proposed locomotive mechanism is not only applicable to micro capsule endoscopes but also effective to advance inside of intestinal tract.

  4. Risk of transmission of carbapenem-resistant Enterobacteriaceae and related “superbugs” during gastrointestinal endoscopy

    PubMed Central

    Muscarella, Lawrence F

    2014-01-01

    To evaluate the risk of transmission of carbapenem-resistant Enterobacteriaceae (CRE) and their related superbugs during gastrointestinal (GI) endoscopy. Reports of outbreaks linked to GI endoscopes contaminated with different types of infectious agents, including CRE and their related superbugs, were reviewed. Published during the past 30 years, both prior to and since CRE’s emergence, these reports were obtained by searching the peer-reviewed medical literature (via the United States National Library of Medicine’s “MEDLINE” database); the Food and Drug Administration’s Manufacturer and User Facility Device Experience database, or “MAUDE”; and the Internet (via Google’s search engine). This review focused on an outbreak of CRE in 2013 following the GI endoscopic procedure known as endoscopic retrograde cholangiopancreatography, or ERCP, performed at “Hospital X” located in the suburbs of Chicago (IL; United States). Part of the largest outbreak of CRE in United States history, the infection and colonization of 10 and 28 of this hospital’s patients, respectively, received considerable media attention and was also investigated by the Centers for Disease Control and Prevention (CDC), which published a report about this outbreak in Morbidity and Mortality Weekly Report (MMWR), in 2014. This report, along with the results of an independent inspection of Hospital X’s infection control practices following this CRE outbreak, were also reviewed. While this article focuses primarily on the prevention of transmissions of CRE and their related superbugs in the GI endoscopic setting, some of its discussion and recommendations may also apply to other healthcare settings, to other types of flexible endoscopes, and to other types of transmissible infectious agents. This review found that GI endoscopy is an important risk factor for the transmission of CRE and their related superbugs, having been recently associated with patient morbidity and mortality following ERCP. The CDC reported in MMWR that the type of GI endoscope, known as an ERCP endoscope, that Hospital X used to perform ERCP in 2013 on the 38 patients who became infected or colonized with CRE might be particularly challenging to clean and disinfect, because of the complexity of its physical design. If performed in strict accordance with the endoscope manufacturer’s labeling, supplemented as needed with professional organizations’ published guidelines, however, current practices for reprocessing GI endoscopes, which include high-level disinfection, are reportedly adequate for the prevention of transmission of CRE and their related superbugs. Several recommendations are provided to prevent CRE transmissions in the healthcare setting. CRE transmissions are not limited to contaminated GI endoscopes and also have been linked to other reusable flexible endoscopic instrumentation, including bronchoscopes and cystoscopes. In conclusion, contaminated GI endoscopes, particularly those used during ERCP, have been causally linked to outbreaks of CRE and their related superbugs, with associated patient morbidity and mortality. Thorough reprocessing of these complex reusable instruments is necessary to prevent disease transmission and ensure patient safety during GI endoscopy. Enhanced training and monitoring of reprocessing staffers to verify the proper cleaning and brushing of GI endoscopes, especially the area around, behind and near the forceps elevator located at the distal end of the ERCP endoscope, are recommended. If the ERCP endoscope features a narrow and exposed channel that houses a wire connecting the GI endoscope’s control head to this forceps elevator, then this channel’s complete reprocessing, including its flushing with a detergent using a procedure validated for effectiveness, is also emphasized. PMID:25324917

  5. Ling classification describes endoscopic progressive process of achalasia and successful peroral endoscopy myotomy prevents endoscopic progression of achalasia.

    PubMed

    Zhang, Wen-Gang; Linghu, En-Qiang; Chai, Ning-Li; Li, Hui-Kai

    2017-05-14

    To verify the hypothesis that the Ling classification describes the endoscopic progressive process of achalasia and determine the ability of successful peroral endoscopic myotomy (POEM) to prevent endoscopic progression of achalasia. We retrospectively reviewed the endoscopic findings, symptom duration, and manometric data in patients with achalasia. A total of 359 patients (197 women, 162 men) with a mean age of 42.1 years (range, 12-75 years) were evaluated. Symptom duration ranged from 2 to 360 mo, with a median of 36 mo. Patients were classified with Ling type I ( n = 119), IIa ( n = 106), IIb ( n = 60), IIc ( n = 60), or III ( n = 14), according to the Ling classification. Of the 359 patients, 349 underwent POEM, among whom 21 had an endoscopic follow-up for more than 2 years. Pre-treatment and post-treatment Ling classifications of these 21 patients were compared. Symptom duration increased significantly with increasing Ling classification (from I to III) ( P < 0.05), whereas lower esophageal sphincter pressure decreased with increasing Ling type (from I to III) ( P < 0.05). There was no difference in sex ratio or onset age among the Ling types, although the age at time of diagnosis was higher in Ling types IIc and III than in Ling types I, IIa, and IIb. Of the 21 patients, 19 underwent high-resolution manometry both before and after treatment. The mean preoperative and postoperative lower esophageal sphincter pressure were 34.6 mmHg (range, 15.3-59.4 mmHg) and 15.0 mmHg (range, 2.1-21.6 mmHg), respectively, indicating a statistically significant decrease after POEM. All of the 21 patients were treated successfully by POEM (postoperative Eckardt score ≤ 3) and still had the same Ling type during a mean follow-up period of 37.8 mo (range, 24-51 mo). The Ling classification represents the endoscopic progressive process of achalasia and may be able to serve as an endoscopic assessment criterion for achalasia. Successful POEM (Eckardt score ≤ 3) seems to have the ability to prevent endoscopic evolvement of achalasia. However, studies with larger populations are warranted to confirm our findings.

  6. WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, W; Rao, A; Wendt, R

    Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded asmore » it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration framework that is clinically valuable and requires no specialized equipment.« less

  7. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    PubMed

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  8. Endoscopic retrograde cholangiopancreatography-associated AmpC Escherichia coli outbreak.

    PubMed

    Wendorf, Kristen A; Kay, Meagan; Baliga, Christopher; Weissman, Scott J; Gluck, Michael; Verma, Punam; D'Angeli, Marisa; Swoveland, Jennifer; Kang, Mi-Gyeong; Eckmann, Kaye; Ross, Andrew S; Duchin, Jeffrey

    2015-06-01

    We identified an outbreak of AmpC-producing Escherichia coli infections resistant to third-generation cephalosporins and carbapenems (CR) among 7 patients who had undergone endoscopic retrograde cholangiopancreatography at hospital A during November 2012-August 2013. Gene sequencing revealed a shared novel mutation in a bla CMY gene and a distinctive fumC/ fimH typing profile. To determine the extent and epidemiologic characteristics of the outbreak, identify potential sources of transmission, design and implement infection control measures, and determine the association between the CR E. coli and AmpC E. coli circulating at hospital A. We reviewed laboratory, medical, and endoscopy reports, and endoscope reprocessing procedures. We obtained cultures from endoscopes after reprocessing as well as environmental samples and conducted pulsed-field gel electrophoresis and gene sequencing on phenotypic AmpC isolates from patients and endoscopes. Cases were those infected with phenotypic AmpC isolates (both carbapenem-susceptible and CR) and identical bla CMY-2, fumC, and fimH alleles or related pulsed-field gel electrophoresis patterns. Thirty-five of 49 AmpC E. coli tested met the case definition, including all CR isolates. All cases had complicated biliary disease and had undergone at least 1 endoscopic retrograde cholangiopancreatography at hospital A. Mortality at 30 days was 16% for all patients and 56% for CR patients. Two of 8 reprocessed endoscopic retrograde cholangiopancreatography scopes harbored AmpC that matched case isolates by pulsed-field gel electrophoresis. Environmental cultures were negative. No breaches in infection control were identified. Endoscopic reprocessing exceeded manufacturer's recommended cleaning guidelines. Recommended reprocessing guidelines are not sufficient.

  9. A Large Multicenter Experience With Endoscopic Suturing for Management of Gastrointestinal Defects and Stent Anchorage in 122 Patients: A Retrospective Review.

    PubMed

    Sharaiha, Reem Z; Kumta, Nikhil A; DeFilippis, Ersilia M; Dimaio, Christopher J; Gonzalez, Susana; Gonda, Tamas; Rogart, Jason; Siddiqui, Ali; Berg, Paul S; Samuels, Paul; Miller, Larry; Khashab, Mouen A; Saxena, Payal; Gaidhane, Monica R; Tyberg, Amy; Teixeira, Julio; Widmer, Jessica; Kedia, Prashant; Loren, David; Kahaleh, Michel; Sethi, Amrita

    2016-01-01

    To describe a multicenter experience using an endoscopic suturing device for management of gastrointestinal (GI) defects and stent anchorage. Endoscopic closure of GI defects including perforations, fistulas, and anastomotic leaks as well as stent anchorage has improved with technological advances. An endoscopic suturing device (OverStitch; Apollo Endosurgery Inc.) has been used. Retrospective study of consecutive patients who underwent endoscopic suturing for management of GI defects and/or stent anchorage were enrolled between March 2012 and January 2014 at multiple academic medical centers. Data regarding demographic information and outcomes including long-term success were collected. One hundred and twenty-two patients (mean age, 52.6 y; 64.2% females) underwent endoscopic suturing at 8 centers for stent anchorage (n=47; 38.5%), fistulas (n=40; 32.7%), leaks (n=15; 12.3%), and perforations (n=20; 16.4%). A total of 44.2% underwent prior therapy and 97.5% achieved technical success. Immediate clinical success was achieved in 79.5%. Long-term clinical success was noted in 78.8% with mean follow-up of 68 days. Clinical success was 91.4% in stent anchorage, 93% in perforations, 80% in fistulas, but only 27% in anastomotic leak closure. Endoscopic suturing for management of GI defects and stent anchoring is safe and efficacious. Stent migration after stent anchoring was reduced compared with published data. Long-term success without further intervention was achieved in the majority of patients. The role of endoscopic suturing for repair of anastomotic leaks remains unclear given limited success in this retrospective study.

  10. Endoscopic and keyhole endoscope-assisted neurosurgical approaches: a qualitative survey on technical challenges and technological solutions.

    PubMed

    Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2014-10-01

    The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent theme analysis. Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches.

  11. A pilot study on using chlorine dioxide gas for disinfection of gastrointestinal endoscopes* #

    PubMed Central

    Yi, Ying; Hao, Li-mei; Ma, Shu-ren; Wu, Jin-hui; Wang, Tao; Lin, Song; Zhang, Zong-xing; Qi, Jian-cheng

    2016-01-01

    Objectives: This pilot study of employing chlorine dioxide (CD) gas to disinfect gastrointestinal endoscopes was conducted to meet the expectations of many endoscopy units in China for a high-efficiency and low-cost disinfectant. Methods: An experimental prototype with an active circulation mode was designed to use CD gas to disinfect gastrointestinal endoscopes. One type of testing device composed of polytetrafluoroethylene (PTFE) tubes (2 m long, inner diameter 1 mm) and bacterial carrier containers was used to simulate the channel of the endoscope. PTFE bacterial carriers inoculated with Bacillus atrophaeus with or without organic burden were used to evaluate the sporicidal activity of CD gas. Factors including exposure dosage, relative humidity (RH), and flow rate (FR) influencing the disinfection effect of CD gas were investigated. Moreover, an autoptic disinfecting test on eight real gastrointestinal endoscopes after clinical use was performed using the experimental prototype. Results: RH, exposure dosage, organic burden, and the FR through the channel significantly (P<0.05) affected the disinfection efficacy of CD gas for a long and narrow lumen. The log reduction increased as FR decreased. Treatment with 4 mg/L CD gas for 30 min at 0.8 L/min FR and 75% RH, resulted in complete inactivation of spores. Furthermore, all eight endoscopes with a maximum colony-forming unit of 915 were completely disinfected. The cost was only 3 CNY (0.46 USD) for each endoscope. Conclusions: The methods and results reported in this study could provide a basis for further studies on using CD gas for the disinfection of endoscopes. PMID:27381729

  12. Prospective Clinical Trial of Robotically Assisted Endoscopic Coronary Grafting With 1-Year Follow-Up

    PubMed Central

    Prasad, Sunil M.; Ducko, Christopher T.; Stephenson, Edward R.; Chambers, Charles E.; Damiano, Ralph J.

    2001-01-01

    Objective To follow up in prospective fashion patients with coronary artery anastomoses completed endoscopically with robotic assistance. The robotic system was evaluated for safety and its effectiveness in completing microsurgical coronary anastomoses. Summary Background Data Recently there has been an interest in using robotics and computers to enhance the surgeon’s ability to perform endoscopic cardiac surgery. This interest has stemmed from the rapid advancement of technology and the desire to make cardiac surgery less invasive. Using traditional endoscopic instruments, it has not been possible to perform coronary surgery. Methods Nineteen patients underwent robotically assisted endoscopic coronary artery bypass grafting of the left internal thoracic artery (LITA) to the left anterior descending artery (LAD). Two robotic instruments and one endoscopic camera were placed through three 5-mm ports. A robotic system was used to construct the LITA–LAD anastomosis. All other required grafts were completed by conventional techniques. Results Seventeen LITA–LAD grafts (89%) had adequate intraoperative flow. The mean LITA–LAD graft flow was 38.5 ± 5 mL/min. At 8 weeks, LITA–LAD grafts were assessed by angiography and showed 100% patency with thrombolysis in myocardial infarction (TIMI) I flow. At a mean follow-up of 17 ± 4.2 months, all patients were NYHA class I and there were no adverse cardiac events. Conclusions The results from the first prospective clinical trial of robotically assisted endoscopic coronary bypass surgery in the United States showed favorable short-term outcomes with no adverse events. Robotic assistance is an enabling technology allowing the performance of endoscopic coronary anastomoses. PMID:11371730

  13. Evaluation of endoscopic entire 3D image acquisition of the digestive tract using a stereo endoscope

    NASA Astrophysics Data System (ADS)

    Yoshimoto, Kayo; Watabe, Kenji; Fujinaga, Tetsuji; Iijima, Hideki; Tsujii, Masahiko; Takahashi, Hideya; Takehara, Tetsuo; Yamada, Kenji

    2017-02-01

    Because the view angle of the endoscope is narrow, it is difficult to get the whole image of the digestive tract at once. If there are more than two lesions in the digestive tract, it is hard to understand the 3D positional relationship among the lesions. Virtual endoscopy using CT is a present standard method to get the whole view of the digestive tract. Because the virtual endoscopy is designed to detect the irregularity of the surface, it cannot detect lesions that lack irregularity including early cancer. In this study, we propose a method of endoscopic entire 3D image acquisition of the digestive tract using a stereo endoscope. The method is as follows: 1) capture sequential images of the digestive tract by moving the endoscope, 2) reconstruct 3D surface pattern for each frame by stereo images, 3) estimate the position of the endoscope by image analysis, 4) reconstitute the entire image of the digestive tract by combining the 3D surface pattern. To confirm the validity of this method, we experimented with a straight tube inside of which circles were allocated at equal distance of 20 mm. We captured sequential images and the reconstituted image of the tube revealed that the distance between each circle was 20.2 +/- 0.3 mm (n=7). The results suggest that this method of endoscopic entire 3D image acquisition may help us understand 3D positional relationship among the lesions such as early esophageal cancer that cannot be detected by virtual endoscopy using CT.

  14. Evaluation of the tip-bending response in clinically used endoscopes.

    PubMed

    Rozeboom, Esther D; Reilink, Rob; Schwartz, Matthijs P; Fockens, Paul; Broeders, Ivo A M J

    2016-04-01

    Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current technique of endoscope tip control is adequate for a future of high precision procedures, steerable accessories, and add-on robotics. The aim of this study was to determine the status of the tip response of endoscopes used in clinical practice. We evaluated 20 flexible colonoscopes and five gastroscopes, used in the endoscopy departments of a Dutch university hospital and two Dutch teaching hospitals, in a bench top setup. First, maximal tip bending was determined manually. Next, the endoscope navigation wheels were rotated individually in a motor setup. Tip angulation was recorded with a USB camera. Cable slackness was derived from the resulting hysteresis plot. Only two of the 20 colonoscopes (10 %) and none of the five gastroscopes reached the maximal tip angulation specified by the manufacturer. Four colonoscopes (20 %) and none of the gastroscopes demonstrated the recommended cable tension. Eight colonoscopes (40 %) had undergone a maintenance check 1 month before the measurements were made. The tip responses of these eight colonoscopies did not differ significantly from the tip responses of the other colonoscopes. This study suggests that the majority of clinically used endoscopes are not optimally tuned to reach maximal bending angles and demonstrate adequate tip responses. We suggest a brief check before procedures to predict difficulties with bending angles and tip responses.

  15. Laparoscopic Adjustable Gastric Band (LAGB) Migration - Endoscopic Treatment Modalities.

    PubMed

    Klimczak, Tomasz; Szewczyk, Tomasz; Janczak, Przemysław; Jurałowicz, Piotr

    2016-12-01

    Laparoscopic adjustible gastric binding (LAGB) is one of most common surgical methods of treating obesity. Gastric band migration (erosion) is a typical LAGB complication, with a frequency of about 1-4%. The aim of the study was to present the possibilities of endoscopic diagnosis and treatment of this complication. The study was carried out in the Department of Gastroenterological, Oncological and General Surgery in Łódź. Between 2008 and 2015, 450 gastric bands were implanted using the laparoscopic technique in 318 (71%) women and 132 (29%) men. In this period 7 cases of band migration were diagnosed - 3 cases in men (2.3%) and 4 cases in women (1.3%), what presents 1.56% of general number of complications. Five out of 7 eroded bands were qualified for endoscopic removal. Four out of 5 qualified eroded bands were removed using the gastric band cutting technique. In one case we used the musculo-mucosal incision technique. In order to diagnose early perforations all patients underwent control passage examinations with oral contrast (gastrografin) 3-6 hours after the procedure. All 5 out of 5 qualified eroded gastric bands were successfully removed with the endoscopic method, which gives 100% success rate in own material. Two endoscopic methods were used: 1) endoscopic gastric band cutting, 2) endoscopic musculo-mucosal incision. Endoscopy gives a possibility of instant diagnosis of gastric band migration and early minimally invasive treatment. One of our endoscopic methods of removing the bands by making several incisions of the musculo-mucosal plicae has not yet been described in professional medical literature.

  16. Endoscopic management of complications of self-expandable metal stents for treatment of malignant esophageal stenosis and tracheoesophageal fistulas.

    PubMed

    Bor, Renáta; Fábián, Anna; Bálint, Anita; Farkas, Klaudia; Szűcs, Mónika; Milassin, Ágnes; Czakó, László; Rutka, Mariann; Molnár, Tamás; Szepes, Zoltán

    2017-08-01

    Self-expandable metal stent (SEMS) implantation may rapidly improve the symptoms of malignant esophageal stenosis and tracheoesophageal fistulas (TEF). However, dysphagia often returns subsequently and repeated endoscopic intervention may be necessary. The aims of the study were to identify the risk factors of complications, and the frequency and efficacy of repeated endoscopic interventions; and to provide technical recommendations on appropriate stent selection. We analyzed retrospectively the clinical data of 212 patients with locally advanced esophageal cancer who underwent SEMS implantation. A total of 238 SEMS implantations were performed with 99.06% technical success and 1.26% procedure-related deaths in the enrolled 212 cases. Complications occurred in 84 patients (39.62%) and in 55 cases (25.94%) repeated endoscopic procedures were required. Early reintervention 24-48 h after the stent implantations was necessary due to stent migration (12 cases), arrhythmia (2 cases), intolerable retrosternal pain (1 case) and dyspnea (1 case). An average of 1.98 repeated gastroscopies (range 1-6; median 2), 13.58 weeks (range 1.5-48; median 11) after the stent implantation were performed during the follow-up period: 37 stent repositions, 23 restent implantations, 15 endoscopic esophageal dilations and 7 stent removals. In 48 cases (87.3%) oral feeding of patients was made possible by endoscopic interventions. In a quarter of SEMS implantations, complications occur that can be successfully managed by endoscopic interventions. Our experiences have shown that individualized stent choice may substantially reduce the complications rate and make repeated endoscopic interventions easier.

  17. [Study on the situation regarding endoscope cleaning and disinfection in the department of otolaryngology in Hunan hospitals].

    PubMed

    Wang, Fang; Li, Wei; Li, Rong; Tan, Guolin; Luo, Dan

    2016-05-01

    To investigate the situation regarding the cleaning and sterilization of endonasal endoscopes in department of otolaryngology in Hunan Province, and to provide strategy for improving the level of sterilization and management of endonasal endoscopes.
 A total of 100 medical institutions were investigated by spot assessment, check and sampling. Data was analyzed by multivariate analysis.
 The qualified rate of rules and regulations for endoscopy was 28.8% in the second-class hospitals and 45% in the top-class hospitals. The qualified rate of environment for endoscopy cleaning and sterilization was 36.3% in the second-class hospitals and 85% in the top-class hospitals. The main problems include lack of independent disinfection room, the space not large enough, and/or lack of ventilation system. The qualified rate of bacterial detection for post-sterilized endoscopes and biopsy forceps was 93.8% in the second-class hospitals and 95.0% in the top-class hospitals, and the main pathogenic bacteria was gram-positive cocci and gram-negative bacilli. The multivariate analysis showed that the influencial factors for endoscope cleaning and disinfection are as follows: staffs responsible for the cleaning and sterilization of otolaryngology endoscopes, the standard for cleaning and disinfection process, and the frequency of endoscope use.
 The present situation of cleaning and sterilization for otolaryngology endoscopes is better in the top-class hospitals than that in the second-class hospitals. The sterilization and management of otolaryngology endoscopy are needed to be improved, and the staff training is needed, especially in the primary hospitals.

  18. A panoramic view of the skull base: systematic review of open and endoscopic endonasal approaches to four tumors.

    PubMed

    Graffeo, Christopher S; Dietrich, August R; Grobelny, Bartosz; Zhang, Meng; Goldberg, Judith D; Golfinos, John G; Lebowitz, Richard; Kleinberg, David; Placantonakis, Dimitris G

    2014-08-01

    Endoscopic endonasal surgery has been established as the safest approach to pituitary tumors, yet its role in other common skull base lesions has not been established. To answer this question, we carried out a systematic review of reported series of open and endoscopic endonasal approaches to four major skull base tumors: olfactory groove meningiomas (OGM), tuberculum sellae meningiomas (TSM), craniopharyngiomas (CRA), and clival chordomas (CHO). Data from 162 studies containing 5,701 patients were combined and compared for differences in perioperative mortality, gross total resection (GTR), cerebrospinal fluid (CSF) leak, neurological morbidity, post-operative visual function, post-operative anosmia, post-operative diabetes insipidus (DI), and post-operative obesity/hyperphagia. Weighted average rates for each outcome were calculated using relative study size. Our findings indicate similar rates of GTR and perioperative mortality between open and endoscopic approaches for all tumor types. CSF leak was increased after endoscopic surgery. Visual function symptoms were more likely to improve after endoscopic surgery for TSM, CRA, and CHO. Post-operative DI and obesity/hyperphagia were significantly increased after open resection in CRA. Recurrence rates per 1,000 patient-years of follow-up were higher in endoscopy for OGM, TSM, and CHO. Trends for open and endoscopic surgery suggested modest improvement in all outcomes over time. Our observations suggest that endonasal endoscopy is a safe alternative to craniotomy and may be preferred for certain tumor types. However, endoscopic surgery is associated with higher rates of CSF leak, and possibly increased recurrence rates. Prospective study with long-term follow-up is required to verify these preliminary observations.

  19. Endoscopic electrocautery dilation of benign anastomotic colonic strictures: a single-center experience.

    PubMed

    Bravi, Ivana; Ravizza, Davide; Fiori, Giancarla; Tamayo, Darina; Trovato, Cristina; De Roberto, Giuseppe; Genco, Chiara; Crosta, Cristiano

    2016-01-01

    Benign anastomotic colonic stenosis sometimes occur after surgery and usually require surgical or endoscopic dilation. Endoscopic dilation of anastomotic colonic strictures by using balloon or bougie-type dilators has been demonstrated to be safe and effective in multiple uncontrolled series. However, few data are available on safety and efficacy of endoscopic electrocautery dilation. The aim of our study was to retrospectively investigate safety and efficacy of endoscopic electrocautery dilation of postsurgical benign anastomotic colonic strictures. Sixty patients (37 women; median age 63.6 years, range 22.6-81.7) with benign anastomotic colonic or rectal strictures treated with endoscopic electrocautery dilation between June 2001 and February 2013 were included in the study. Anastomotic stricture was defined as a narrowed anastomosis through which a standard colonoscope could not be passed. Only annular anastomotic strictures were considered suitable for electrocautery dilation which consisted of radial incisions performed with a precut sphincterotome. Treatment was considered successful if the colonic anastomosis could be passed by a standard colonoscope immediately after dilation. Recurrence was defined as anastomotic stricture reappearance during follow-up. The time interval between colorectal surgery and the first endoscopic evaluation or symptoms development was 7.3 months (1.3-60.7). Electrocautery dilation was successful in all the patients. There were no procedure-related complications. Median follow-up was 35.5 months (2.0-144.0). Anastomotic stricture recurrence was observed in three patients who were successfully treated with electrocautery dilation and Savary dilation. Endoscopic electrocautery dilation is a safe and effective treatment for annular benign anastomotic postsurgical colonic strictures.

  20. Single-session endoscopic resection and focal radiofrequency ablation for short-segment Barrett's esophagus with early neoplasia.

    PubMed

    Barret, Maximilien; Belghazi, Kamar; Weusten, Bas L A M; Bergman, Jacques J G H M; Pouw, Roos E

    2016-07-01

    The management of early neoplasia in Barrett's esophagus (BE) requires endoscopic resection of visible lesions, followed by radiofrequency ablation (RFA) of the remaining BE. We evaluated the safety and efficacy of combining endoscopic resection and focal RFA in a single endoscopic session in patients with early BE neoplasia. This was a retrospective analysis of patients with early BE neoplasia and a visible lesion undergoing combined endoscopic resection and focal RFA in a single session. Consecutive ablation procedures were performed every 8 to 12 weeks until complete endoscopic and histologic eradication of dysplasia and intestinal metaplasia were reached. Forty patients were enrolled, with a median C1M2 BE segment, a visible lesion with a median diameter of 15 mm, and invasive carcinoma in 68% of cases. Endoscopic resection was performed by using the multiband mucosectomy technique in 80% of cases, and the Barrx(90) catheter (Barrx Medical, Sunnyvale, Calif) was used for focal ablation. When an intention-to-treat analysis was used, both complete remission of all neoplasia and intestinal metaplasia were 95% after a median follow-up of 19 months. Stenoses occurred in 33% of cases and were successfully managed with a median number of 2 dilations. In 43% of patients, 1 single-session treatment resulted in complete histologic remission of intestinal metaplasia. Combining endoscopic resection and focal RFA in a single session appears to be effective. Less-aggressive RFA regimens could limit the adverse event rates. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  1. The Implications of Endoscopic Ulcer in Early Gastric Cancer: Can We Predict Clinical Behaviors from Endoscopy?

    PubMed Central

    Lee, Yoo Jin; Kim, Jie-Hyun; Park, Jae Jun; Youn, Young Hoon; Park, Hyojin; Kim, Jong Won; Choi, Seung Ho; Noh, Sung Hoon

    2016-01-01

    Background The presence of ulcer in early gastric cancer (EGC) is important for the feasibility of endoscopic resection, only a few studies have examined the clinicopathological implications of endoscopic ulcer in EGC. Objectives To determine the role of endoscopic ulcer as a predictor of clinical behaviors in EGC. Methods Data of 3,270 patients with EGC who underwent surgery between January 2005 and December 2012 were reviewed. Clinicopathological characteristics were analyzed in relation to the presence and stage of ulcer in EGC. Based on endoscopic findings, the stage of ulcer was categorized as active, healing, or scar. Logistic regression analysis was performed to analyze factors associated with lymph node metastasis (LNM). Results 2,343 (71.7%) patients had endoscopic findings of ulceration in EGC. Submucosal (SM) invasion, LNM, lymphovascular invasion (LVI), perineural invasion, and undifferentiated-type histology were significantly higher in ulcerative than non-ulcerative EGC. Comparison across different stages of ulcer revealed that SM invasion, LNM, and LVI were significantly associated with the active stage, and that these features exhibited significant stage-based differences, being most common at the active stage, and least common at the scar stage. The presence of endoscopic ulcer and active status of the ulcer were identified as independent risk factors for LNM. Conclusions Ulcerative EGC detected by endoscopy exhibited more aggressive behaviors than non-ulcerative EGC. Additionally, the endoscopic stage of ulcer may predict the clinicopathological behaviors of EGC. Therefore, the appearance of ulcers should be carefully evaluated to determine an adequate treatment strategy for EGC. PMID:27741275

  2. Evaluation of the Turkish translation of the Minimal Standard Terminology for Digestive Endoscopy by development of an endoscopic information system.

    PubMed

    Atalağ, Koray; Bilgen, Semih; Gür, Gürden; Boyacioğlu, Sedat

    2007-09-01

    There are very few evaluation studies for the Minimal Standard Terminology for Digestive Endoscopy. This study aims to evaluate the usage of the Turkish translation of Minimal Standard Terminology by developing an endoscopic information system. After elicitation of requirements, database modeling and software development were performed. Minimal Standard Terminology driven forms were designed for rapid data entry. The endoscopic report was rapidly created by applying basic Turkish syntax and grammar rules. Entering free text and also editing of final report were possible. After three years of live usage, data analysis was performed and results were evaluated. The system has been used for reporting of all endoscopic examinations. 15,638 valid records were analyzed, including 11,381 esophagogastroduodenoscopies, 2,616 colonoscopies, 1,079 rectoscopies and 562 endoscopic retrograde cholangiopancreatographies. In accordance with other previous validation studies, the overall usage of Minimal Standard Terminology terms was very high: 85% for examination characteristics, 94% for endoscopic findings and 94% for endoscopic diagnoses. Some new terms, attributes and allowed values were also added for better clinical coverage. Minimal Standard Terminology has been shown to cover a high proportion of routine endoscopy reports. Good user acceptance proves that both the terms and structure of Minimal Standard Terminology were consistent with usual clinical thinking. However, future work on Minimal Standard Terminology is mandatory for better coverage of endoscopic retrograde cholangiopancreatographies examinations. Technically new software development methodologies have to be sought for lowering cost of development and the maintenance phase. They should also address integration and interoperability of disparate information systems.

  3. Use of a real-time viewer for endoscopic deployment of capsule endoscope in the pediatric population.

    PubMed

    Bass, Lee M; Misiewicz, Lawrence

    2012-11-01

    Wireless capsule endoscopy (WCE) is an increasingly used procedure for visualization of the small intestine. One challenge in pediatric WCE is the placement of the capsule in a population unable to swallow it for a variety of reasons. Here we present a novel use of the real-time (RT) viewer in the endoscopic deployment of the capsule endoscope. We performed a retrospective chart review on all WCE completed at the Children's Memorial Hospital from February 2010 to May 2011. Following a diagnostic upper endoscopy, the RT viewer was attached to the capsule recorder and image was noted before insertion. The endoscope and AdvanCE capsule delivery device were slowly advanced into duodenum while maintaining visualization on the RT viewer. A total of 17 patients who underwent a WCE with endoscopic placement were identified. They ranged in ages from 2 to 19 years. Thirteen patients required endoscopic placement because of the inability to swallow the capsule, whereas 4 were placed during a scheduled procedure to take advantage of sedation and airway protection. All of the 17 patients had successful deployment of the capsule into the duodenal lumen. In each case, the endoscopist was able to confirm capsule location in duodenum during scope withdrawal. There was no evidence of iatrogenic trauma or bleeding in any patient. There were 5 incomplete studies, a completion rate consistent with that described in the literature. The use of the RT viewer for endoscopic deployment of WCE is an effective technique to improve visualization of capsule placement in the pediatric population.

  4. Evaluation of the tip-bending response in clinically used endoscopes

    PubMed Central

    Rozeboom, Esther D.; Reilink, Rob; Schwartz, Matthijs P.; Fockens, Paul; Broeders, Ivo A. M. J.

    2016-01-01

    Background and study aims: Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current technique of endoscope tip control is adequate for a future of high precision procedures, steerable accessories, and add-on robotics. The aim of this study was to determine the status of the tip response of endoscopes used in clinical practice. Materials and methods: We evaluated 20 flexible colonoscopes and five gastroscopes, used in the endoscopy departments of a Dutch university hospital and two Dutch teaching hospitals, in a bench top setup. First, maximal tip bending was determined manually. Next, the endoscope navigation wheels were rotated individually in a motor setup. Tip angulation was recorded with a USB camera. Cable slackness was derived from the resulting hysteresis plot. Results: Only two of the 20 colonoscopes (10 %) and none of the five gastroscopes reached the maximal tip angulation specified by the manufacturer. Four colonoscopes (20 %) and none of the gastroscopes demonstrated the recommended cable tension. Eight colonoscopes (40 %) had undergone a maintenance check 1 month before the measurements were made. The tip responses of these eight colonoscopies did not differ significantly from the tip responses of the other colonoscopes. Conclusion: This study suggests that the majority of clinically used endoscopes are not optimally tuned to reach maximal bending angles and demonstrate adequate tip responses. We suggest a brief check before procedures to predict difficulties with bending angles and tip responses. PMID:27092330

  5. Endoscopic and Keyhole Endoscope-assisted Neurosurgical Approaches: A Qualitative Survey on Technical Challenges and Technological Solutions

    PubMed Central

    Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2014-01-01

    Introduction The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. Materials and Methods All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent themes analysis. Results Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). Discussion The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Conclusions Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches. PMID:24533591

  6. Flexible Vesiculovasoscopy Using a Microoptical System in a Human Cadaver Model: An Experimental Approach for Atraumatic Endoscopy of the Seminal Tract.

    PubMed

    Schlager, Daniel; Maas, Moritz; Hein, Simon; Adams, Fabian; Schoenthaler, Martin; Wetterauer, Ulrich; Diemer, Thorsten; Weidner, Wolfgang; Miernik, Arkadiusz

    2016-08-01

    The most common pathologies of the seminal tract are persistent hematospermia, seminal vesicle stones, and seminal duct obstruction. Endoscopic diagnostic work-up of the seminal tract is impeded by complex anatomy and lack of technical equipment. To date, there is no standardized endoscopic approach. The purpose of this study was to investigate the applicability and feasibility of a flexible microoptical device for atraumatic endoscopy of the seminal tract in a male human cadaver. The transurethral endoscopic examination was performed on a male cadaver. No premortal interventions or diseases of the genitourinary tract had been reported. The seminal orifice was identified via cystoscopy and accessed by the Seldinger technique using a hydrophilic guidewire and ureteral catheter. Retrograde endoscopic inspection of the distal seminal tract was performed using a miniaturized flexible endoscope. An antegrade endoscopic inspection of the seminal tract was carried out via high scrotal access to the vas deferens. Structures of the seminal tract, such as the ejaculatory duct, seminal vesicles, and distal portion of the ductus deferentes, were visualized using the miniaturized endoscope. Image quality allowed identification of anatomical structures and characterization of tissue properties. The technical limitations we observed involved the system's maneuverability. Initial results of this novel endoscopic approach to the seminal tract using a flexible microoptical system are encouraging. However, considerable anatomical limitations of the targeted organs necessitate further refinements of the technical equipment. This approach might improve diagnostics and treatment of genitourinary diseases. Future surgical techniques may include intraseminal laser therapy or endoocclusion to monitor fertility in men.

  7. An Audit to Evaluate the Safety and Efficacy of Percutaneous Endoscopic Gastrostomy Placement in Patients with Learning Disabilities

    ERIC Educational Resources Information Center

    Ayres, Lachlan; Black, Chris; Scheepers, Mark; Shaw, Ian

    2015-01-01

    Percutaneous endoscopic gastrostomy insertion is an effective method of providing enteral nutrition to patients with neurologically unsafe swallowing or failure of feeding. Patients with severe learning disabilities may develop unsafe swallowing and benefit from percutaneous endoscopic gastrostomy placement. It is unclear whether this intervention…

  8. Extraction of endoscopic images for biomedical figure classification

    NASA Astrophysics Data System (ADS)

    Xue, Zhiyun; You, Daekeun; Chachra, Suchet; Antani, Sameer; Long, L. R.; Demner-Fushman, Dina; Thoma, George R.

    2015-03-01

    Modality filtering is an important feature in biomedical image searching systems and may significantly improve the retrieval performance of the system. This paper presents a new method for extracting endoscopic image figures from photograph images in biomedical literature, which are found to have highly diverse content and large variability in appearance. Our proposed method consists of three main stages: tissue image extraction, endoscopic image candidate extraction, and ophthalmic image filtering. For tissue image extraction we use image patch level clustering and MRF relabeling to detect images containing skin/tissue regions. Next, we find candidate endoscopic images by exploiting the round shape characteristics that commonly appear in these images. However, this step needs to compensate for images where endoscopic regions are not entirely round. In the third step we filter out the ophthalmic images which have shape characteristics very similar to the endoscopic images. We do this by using text information, specifically, anatomy terms, extracted from the figure caption. We tested and evaluated our method on a dataset of 115,370 photograph figures, and achieved promising precision and recall rates of 87% and 84%, respectively.

  9. Magnetic anchor guidance for endoscopic submucosal dissection and other endoscopic procedures

    PubMed Central

    Mortagy, Mohamed; Mehta, Neal; Parsi, Mansour A; Abe, Seiichiro; Stevens, Tyler; Vargo, John J; Saito, Yutaka; Bhatt, Amit

    2017-01-01

    Endoscopic submucosal dissection (ESD) is a well-established, minimally invasive treatment for superficial neoplasms of the gastrointestinal tract. The universal adoption of ESD has been limited by its slow learning curve, long procedure times, and high risk of complications. One technical challenge is the lack of a second hand that can provide traction, as in conventional surgery. Reliable tissue retraction that exposes the submucosal plane of dissection would allow for safer and more efficient dissection. Magnetic anchor guided endoscopic submucosal dissection (MAG-ESD) has potential benefits compared to other current traction methods. MAG-ESD offers dynamic tissue retraction independent of the endoscope mimicking a surgeon’s “second hand”. Two types of magnets can be used: electromagnets and permanent magnets. In this article we review the MAG-ESD technology, published work and studies of magnets in ESD. We also review the use of magnetic anchor guidance systems in natural orifice transluminal endoscopic surgery and the idea of magnetic non-contact retraction using surface ferromagentization. We discuss the current limitations, the future potential of MAG-ESD and the developments needed for adoption of this technology. PMID:28522906

  10. Effectiveness of endoscopic cricopharyngeal myotomy in adults with neurological disease: systematic review.

    PubMed

    Gilheaney, Ó; Kerr, P; Béchet, S; Walshe, M

    2016-12-01

    To determine the effectiveness of endoscopic cricopharyngeal myotomy on upper oesophageal sphincter dysfunction in adults with upper oesophageal sphincter dysfunction and neurological disease. Published and unpublished studies with a quasi-experimental design investigating endoscopic cricopharyngeal myotomy effects on upper oesophageal sphincter dysfunction in humans were considered eligible. Electronic databases, grey literature and reference lists of included studies were systematically searched. Data were extracted by two independent reviewers. Methodological quality was assessed independently using the PEDro scale and MINORS tool. Of 2938 records identified, 2 studies were eligible. Risk of bias assessment indicated areas of methodological concern in the literature. Statistical analysis was not possible because of the limited number of eligible studies. No determinations could be made regarding endoscopic cricopharyngeal myotomy effectiveness in the cohort of interest. Reliable and valid evidence on the following is required to support increasing clinical usage of endoscopic cricopharyngeal myotomy: optimal candidacy selection; standardised post-operative management protocol; complications; and endoscopic cricopharyngeal myotomy effects on aspiration of food and laryngeal penetration, mean upper oesophageal sphincter resting pressure and quality of life.

  11. Working channel endoscope in lumbar spine surgery.

    PubMed

    Choi, G; Lee, S H; Deshpande, K; Choi, H

    2014-06-01

    Percutaneous endoscopic lumbar discectomy (PELD) is a well established modality in the treatment of patients with herniated lumbar discs. Since the time of its inception towards the end of 20th century, this technique has undergone significant modifications. With better understanding of the patho-anatomy and development of instrumentation the indications for PELD are on the rise. In the modern era of knowledge exchange there have been considerable variations among different endoscopic surgeons about classical indications and the implications of a particular technique pertaining to those indications. During last 15 years of experience in practicing endoscopic surgery, Choi has published many articles, regarding the techniques of PELD, across many scientific journals. In our practice there has been considerable shift from central debulking to discectomy to selective fragmentectomy. With further advancements the span of this technique is definitely on the rise. Here, we wish to share all the published data along with my current practice trends in more precise manner to help newer endoscopic spine surgeons understand the implications and limitations of a working channel endoscope in lumbar spine pathologies.

  12. Robotics in endoscopy.

    PubMed

    Klibansky, David; Rothstein, Richard I

    2012-09-01

    The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.

  13. The Combination Therapy of Dissolution Using Carbonated Liquid and Endoscopic Procedure for Bezoars: Pragmatical and Clinical Review

    PubMed Central

    Ogawa, Kohei; Mizuno, Ken-ichi; Shinagawa, Yoko; Kobayashi, Yuji; Abe, Hiroyuki; Watanabe, Yukari; Takahashi, Shunsaku; Hayashi, Kazunao; Yokoyama, Junji; Takeuchi, Manabu; Yamagiwa, Satoshi; Sato, Yuichi; Terai, Shuji

    2016-01-01

    Bezoars are relatively rare foreign bodies of gastrointestinal tract and often cause ileus and ulcerative lesions in the stomach and subsequent bleeding and perforation due to their size and stiffness. Therefore, the removal of bezoars is essential and recent development of devices, the endoscopic removal procedure, is often applied. However, due to their stiffness, simple endoscopic removal failed in not a few cases, and surgical removal has also been used. Recently, the efficacy of a combination therapy of endoscopic procedure and dissolution using carbonated liquid has been reported. To develop the safe and effective removal procedure, we carefully reviewed a total of 55 reported cases in this study including our 3 additional cases, successfully treated with dissolution with endoscopic fragmentation. In summary, the data showed the efficiency in the combination therapy, treating the larger size of bezoar and reducing the length of hospital stay. To the best of our knowledge, this is the largest pragmatical and clinical review for the combination therapy of dissolution and endoscopic treatment for bezoars. This review should help physicians to manage bezoars more efficiently. PMID:27642293

  14. The endoscopic stapler diverticulotomy for Zenker's diverticulum.

    PubMed

    Manni, Johannes J; Kremer, Bernd; Rinkel, Rico N P M

    2004-02-01

    This paper describes the surgical procedure of the endoscopic stapler treatment of Zenker's diverticulum and analyzes the results of 24 consecutive operated patients. In three patients the endoscopic exposure of the diverticulum was not possible. Twenty-one patients underwent endoscopic stapler treatment without any peri- or postoperative complications. The follow-up period was 4 to 29 months (average 18 months). The average total time for surgery was 25 min. Postoperatively, a nasogastric feeding tube was not necessary: all patients resumed oral intake 12 h after surgery. Discharge from the hospital followed the 2nd postoperative day. All patients had complete or nearly complete resolution of symptoms at the 4-month follow-up. Recurrent complaints were an indication for repeat of the contrast barium esophagram. Two patients revealed a residual diverticulum 7 and 11 months after treatment. In comparison with results and complication rates in the literature of the external, transcutaneous techniques and endoscopic diverticulotomy procedures, the endoscopic stapler treatment of Zenker's diverticulum is a safe, (cost-)effective and minimally invasive method and to be considered as the initial treatment of choice.

  15. [Transsphenoidal endoscopic endonasal approach for the surgery of pituitary abscess].

    PubMed

    Yu, Huanxin; Liu, Gang

    2014-01-01

    To evaluate the effectiveness of transsphenoidal endoscopic endonasal approach for the surgery of pituitary abscess. Eighteen pathologically diagnosed pituitary abscess were resected through transsphenoidal endoscopic endonasal approach at Tianjing Huanhu hospital between January 2000 and December 2011.Retrospective analysis was done upon clinical presentations and imaging features. There were 6 males and 12 females. The average age was 48.5 years old and the average disease course was 5.8 years. The typical clinical manifestations included headache (13 cases), pituitary dysfunction (10 cases), Diabetes Insipidus (4 cases) visual interference (8 cases) and fever (4 cases). All cases were resected by transsphenoidal endoscopic endonasal approach with general anesthesia. The postoperative symptoms and follow-up results were recorded. All patients were followed up from 6 months to 6 years. Postoperatively, headache was recovered in 13 cases, visual was improved in 6 cases, hypopituitarism was relieved in 8 cases and polyuria was disappeared in 3 cases. One case was recurrent and cured by transsphenoidal endoscopic endonasal approach. Transsphenoidal endoscopic endonasal approach for the surgery of pituitary abscess is effective.

  16. The transition from microscopic to endoscopic transsphenoidal surgery: the experience at Brigham and Women's Hospital.

    PubMed

    Laws, Edward R; Barkhoudarian, Garni

    2014-12-01

    As interest and enthusiasm for the use of the endoscope in transsphenoidal anterior skull base and pituitary surgery increases, neurosurgeons are increasingly adopting endoscopic technology and associated novel concepts. Often this involves a transition from the standard operating microscope as the main means of visualization to the operating endoscope (2D or 3D) during surgery. The authors' experience with this transition is described, including the rationale, advantages and disadvantages of the two surgical techniques. The successful use of endoscopic surgery for a large variety of pathological problems involving the anterior skull base and the pituitary region is presented. Perceived advantages for the patient and the surgeon are described, as is the occasional need for transition back to the microscopic approach. The endoscopic approach and its allied technology are here to stay. They are useful and occasionally preferable methods for treating a variety of suitable lesions involving the anterior skull base. The importance of incorporating the basic principles of skull base surgery is emphasized. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Endoscopic submucosal tunnel dissection for large superficial esophageal squamous cell neoplasms

    PubMed Central

    Zhai, Ya-Qi; Li, Hui-Kai; Linghu, En-Qiang

    2016-01-01

    Endoscopic submucosal dissection (ESD) is a well-established treatment for superficial esophageal squamous cell neoplasms (SESCNs) with no risk of lymphatic metastasis. However, for large SESCNs, especially when exceeding two-thirds of the esophageal circumference, conventional ESD is time-consuming and has an increased risk of adverse events. Based on the submucosal tunnel conception, endoscopic submucosal tunnel dissection (ESTD) was first introduced by us to remove large SESCNs, with excellent results. Studies from different centers also reported favorable results. Compared with conventional ESD, ESTD has a more rapid dissection speed and R0 resection rate. Currently in China, ESTD for large SESCNs is an important part of the digestive endoscopic tunnel technique, as is peroral endoscopic myotomy for achalasia and submucosal tunnel endoscopic resection for submucosal tumors of the muscularis propria. However, not all patients with SESCNs are candidates for ESTD, and postoperative esophageal strictures should also be taken into consideration, especially for lesions with a circumference greater than three-quarters. In this article, we describe our experience, review the literature of ESTD, and provide detailed information on indications, standard procedures, outcomes, and complications of ESTD. PMID:26755889

  18. A video-based speed estimation technique for localizing the wireless capsule endoscope inside gastrointestinal tract.

    PubMed

    Bao, Guanqun; Mi, Liang; Geng, Yishuang; Zhou, Mingda; Pahlavan, Kaveh

    2014-01-01

    Wireless Capsule Endoscopy (WCE) is progressively emerging as one of the most popular non-invasive imaging tools for gastrointestinal (GI) tract inspection. As a critical component of capsule endoscopic examination, physicians need to know the precise position of the endoscopic capsule in order to identify the position of intestinal disease. For the WCE, the position of the capsule is defined as the linear distance it is away from certain fixed anatomical landmarks. In order to measure the distance the capsule has traveled, a precise knowledge of how fast the capsule moves is urgently needed. In this paper, we present a novel computer vision based speed estimation technique that is able to extract the speed of the endoscopic capsule by analyzing the displacements between consecutive frames. The proposed approach is validated using a virtual testbed as well as the real endoscopic images. Results show that the proposed method is able to precisely estimate the speed of the endoscopic capsule with 93% accuracy on average, which enhances the localization accuracy of the WCE to less than 2.49 cm.

  19. Design and control of 2-axis tilting actuator for endoscope using ionic polymer metal composites

    NASA Astrophysics Data System (ADS)

    Kim, Sung-Joo; Kim, Chul-Jin; Park, No-Cheol; Yang, Hyun-Seok; Park, Young-Pil

    2009-03-01

    In field of endoscopy, in order to overcome limitation in conventional endoscopy, capsule endoscope has been developed and has been recently applied in medical field in hospital. However, since capsule endoscope moves passively through GI tract by peristalsis, it is not able to control direction of head including camera. It is possible to miss symptoms of disease. Therefore, in this thesis, 2-Axis Tilting Actuator for Endoscope, based on Ionic Polymer Metal Composites (IPMC), is presented. In order to apply to capsule endoscope, the actuator material should satisfy a size, low energy consumption and low working voltage. Since IPMC is emerging material that exhibits a large bending deflection at low voltage, consume low energy and it can be fabricated in any size or any shape, IPMC are selected as an actuator. The system tilts camera module of endoscope to reduce invisible area of the intestines and a goal of tilting angle is selected to be an angle of 5 degrees for each axis. In order to control tiling angle, LQR controller and the full order observer is designed.

  20. Endoscopic ultrasound-guided choledochoduodenostomy after a failed or impossible ERCP.

    PubMed

    Mora Soler, Ana María; Álvarez Delgado, Alberto; Piñero Pérez, María Concepción; Velasco-Guardado, Antonio; Marcos Prieto, Héctor; Rodríguez Pérez, Antonio

    2018-05-01

    endoscopic ultrasound-guided biliary drainage (EUS-BD) is an alternative to percutaneous trans-hepatic biliary drainage (PTBD) in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). this is a retrospective description of six cases of endoscopic ultrasound-guided biliary drainage via choledochoduodenostomy (EUCD), as well as the clinical characteristics, endoscopic procedure, complications and monitoring. all cases had malignant distal biliary obstruction. The procedure was concluded with good drainage in four out of six patients. Two late complications were recorded that were caused by stent migration and there were no deaths related with the procedure. The average monitoring period was six months. EUCD can be considered as a valid therapeutic choice in some selected cases and when performed by a team of expert endoscopists in cases of failed ERCP drainage or as an alternative to PTBD. However, the procedure has some associated complications.

  1. Mucus retention cyst of the maxillary sinus: the endoscopic approach.

    PubMed

    Hadar, T; Shvero, J; Nageris, B I; Yaniv, E

    2000-06-01

    To present our experience of endoscopic surgery for symptomatic mucus retention cyst of the maxillary sinus. Retrospective study. Teaching hospital, Israel. 60 patients with 65 symptomatic cysts of the maxillary sinus who were operated on endoscopically. Only patients with large cysts that filled at least 50% of the sinus space were included. A rigid nasal endoscope was used in all cases; most of the cysts were removed through the natural sinus ostium. Cysts recurred in only two patients during the first postoperative year. There were no complications from the procedure. The endoscopic approach to the treatment of maxillary sinus cyst is associated with a low rate of recurrence (3% in this study) and no complications, and we recommend it as the surgical procedure of choice. Copyright 2000 The British Association of Oral and Maxillofacial Surgeons.

  2. Triple Pancreatic Walled-off Fluid Collections Treated Simultaneously with Endoscopic Transmural Drainage.

    PubMed

    Khalid, Sameen; Abbass, Aamer; Nellis, Eric; Shah, Shashin; Shah, Hiral

    2018-01-09

    Pancreatic pseudocysts and walled-off pancreatic necrosis arise as a complication of pancreatitis. Multiple fluid collections are seen in 5-20% of the patients who have walled-off peripancreatic fluid collections. There is a paucity of data regarding the role of endoscopic transmural drainage in the management of multiple pancreatic fluid collections. In this case report, we present the case of a 72-year-old male with three walled-off pancreatic fluid collections in the setting of acute necrotizing pancreatitis. The patient underwent simultaneous endoscopic ultrasound-assisted cyst gastrostomy and cyst duodenostomy and aggressive irrigation without index endoscopic necrosectomy of the three peripancreatic fluid collections. Significant improvement in the size of the fluid collections was seen on the computed tomography scan, as well as a remarkable immediate clinical improvement after 24 hours of the endoscopic intervention.

  3. Cutting-edge endonasal surgical approaches to thyroid ophthalmopathy.

    PubMed

    Tyler, Matthew A; Zhang, Caroline C; Saini, Alok T; Yao, William C

    2018-04-01

    Thyroid orbitopathy is a poorly understood extrathyroidal manifestation of Graves' disease that can cause disfiguring proptosis and vision loss. Orbital decompression surgery for Graves' orbitopathy (GO) can address both cosmetic and visual sequelae of this autoimmune condition. Endonasal endoscopic orbital decompression provides unmatched visualization and access to inferomedial orbital wall and orbital apex. This review examines the state of the art approaches employed in endonasal endoscopic orbital decompression for GO. Review of literature evaluating novel surgical maneuvers for GO. Studies examining the efficacy of endonasal endoscopic orbital decompression are heterogenous and retrospective in design; however, they reveal this approach to be a safe and effective technique in the management of GO. Subtle variations in endoscopic techniques significantly affect postsurgical outcomes and can be tailored to the specific clinical indication in GO making endonasal endoscopic decompression the most versatile approach available. NA.

  4. Ergonomic problems encountered by the surgical team during video endoscopic surgery.

    PubMed

    Kaya, Oskay I; Moran, Munevver; Ozkardes, Alper B; Taskin, Emre Y; Seker, Gaye E; Ozmen, Mahir M

    2008-02-01

    The aim of this study is to analyze the problems related to the ergonomic conditions faced by video endoscopic surgical teams during video endoscopic surgery by means of a questionnaire. A questionnaire was distributed to 100 medical personnel, from 8 different disciplines, who performed video endoscopic surgeries. Participants were asked to answer 13 questions related to physical, perceptive, and cognitive problems. Eighty-two questionnaires were returned. Although there were differences among the disciplines, participants assessment of various problems ranged from 32% to 72% owing to poor ergonomic conditions. As the problems encountered by the staff during video endoscopic surgery and the poor ergonomic conditions of the operating room affect the productivity of the surgical team and the safety and efficiency of the surgery, redesigning of the instruments and the operating room is required.

  5. A 3D photographic capsule endoscope system with full field of view

    NASA Astrophysics Data System (ADS)

    Ou-Yang, Mang; Jeng, Wei-De; Lai, Chien-Cheng; Kung, Yi-Chinn; Tao, Kuan-Heng

    2013-09-01

    Current capsule endoscope uses one camera to capture the surface image in the intestine. It can only observe the abnormal point, but cannot know the exact information of this abnormal point. Using two cameras can generate 3D images, but the visual plane changes while capsule endoscope rotates. It causes that two cameras can't capture the images information completely. To solve this question, this research provides a new kind of capsule endoscope to capture 3D images, which is 'A 3D photographic capsule endoscope system'. The system uses three cameras to capture images in real time. The advantage is increasing the viewing range up to 2.99 times respect to the two camera system. The system can accompany 3D monitor provides the exact information of symptom points, helping doctors diagnose the disease.

  6. [Diagnostic utility of endoscopic ultrasonography elastography and contrast-enhanced harmonic endoscopic ultrasonography in a patient with type 2 autoimmune pancreatitis].

    PubMed

    Yokode, Masataka; Shiomi, Hideyuki; Itai, Ryosuke; Mikami, Sakae; Yamashita, Yukimasa; Nakano, Ryota; Ezaki, Takeshi; Masuda, Atsuhiro; Zen, Yoh

    2018-01-01

    A referring hospital diagnosed a 57-year-old man with a pancreatic head mass. The initial endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) was inconclusive because of the small sample size. Endoscopic ultrasonography elastography (EUS-EG) and contrast-enhanced harmonic endoscopic ultrasonography (CE-EUS), conducted at our institute, raised the possibility of mass-forming pancreatitis or autoimmune pancreatitis (AIP). A repeat EUS-FNA revealed inflammatory changes, including a neutrophilic duct injury suggestive of type 2 AIP. The pancreatic lesion responded well to the steroid therapy. The present case suggests that EUS-EG and CE-EUS may be useful for diagnostic exclusion of pancreatic cancers, and the combined use of EUS-EG and CE-EUS, with EUS-FNA, may help characterize inflammatory pancreatic lesions.

  7. Accuracy of the initial endoscopic diagnosis in the discrimination of gastric ulcers: is endoscopic follow-up study always needed?

    PubMed

    Bustamante, Marco; Devesa, Francesc; Borghol, Abdul; Ortuño, Juan; Ferrando, Maria Jose

    2002-07-01

    Endoscopic follow-up study of gastric ulcers has been recommended routinely because of the possibility that a gastric neoplasm will be missed in the initial endoscopy. Some authors, most of them reporting data from areas of low gastric carcinoma incidence, have questioned this policy because of the low numbers of curable cancers detected and the high cost of such a program. To assess the accuracy of endoscopy diagnosis of gastric ulcers, and to evaluate the efficacy and cost of a gastric ulcer follow-up endoscopic program in an area with an intermediate incidence rate of gastric cancer. A retrospective study was used to identify all the gastroscopies in which a gastric ulcer had been diagnosed during a 6-year period. The endoscopic impression was compared with the histologic diagnosis, sensitivity, specificity, positive and negative predictive values, and the likelihood ratio. Patients who completed a follow-up program also were reviewed. For each neoplasm discovered, the number of endoscopies and global cost were calculated. In the 741 gastroscopies performed, 547 gastric ulcers were diagnosed in 529 patients. Biopsies were taken in 330 patients, in whom 341 gastric ulcers were found. At the index endoscopy, 41 gastric neoplasms (12.4%) were diagnosed. The accuracy of endoscopic malignancy diagnosis was as follows: positive predictive value of 0.68, negative predictive value of 0.98, sensitivity of 0.82, and specificity of 0.95. The likelihood ratio was 16. A total of 117 patients completed the follow-up program. Three new cases of gastric cancer (2.6%) were identified. In these three cases, the initial opinion of the endoscopist was uncertain. In the authors' experience, the cost of each gastric cancer diagnosed has been $4.653 (U.S. dollars). The endoscopic impression correlates with the histologic diagnosis even in a area of intermediate gastric cancer incidence. Endoscopic follow-up study may be restricted to cases of uncertain or malignant endoscopic impression.

  8. [Cost assessment for endoscopic procedures in the German diagnosis-related-group (DRG) system - 5 year cost data analysis of the German Society of Gastroenterology project].

    PubMed

    Rathmayer, Markus; Heinlein, Wolfgang; Reiß, Claudia; Albert, Jörg G; Akoglu, Bora; Braun, Martin; Brechmann, Thorsten; Gölder, Stefan K; Lankisch, Tim; Messmann, Helmut; Schneider, Arne; Wagner, Martin; Dollhopf, Markus; Gundling, Felix; Röhling, Michael; Haag, Cornelie; Dohle, Ines; Werner, Sven; Lammert, Frank; Fleßa, Steffen; Wilke, Michael H; Schepp, Wolfgang; Lerch, Markus M

    2017-10-01

    Background  In the German hospital reimbursement system (G-DRG) endoscopic procedures are listed in cost center 8. For reimbursement between hospital departments and external providers outdated or incomplete catalogues (e. g. DKG-NT, GOÄ) have remained in use. We have assessed the cost for endoscopic procedures in the G-DRG-system. Methods  To assess the cost of endoscopic procedures 74 hospitals, annual providers of cost-data to the Institute for the Hospital Remuneration System (InEK) made their data (2011 - 2015; § 21 KHEntgG) available to the German-Society-of-Gastroenterology (DGVS) in anonymized form (4873 809 case-data-sets). Using cases with exactly one endoscopic procedure (n = 274 186) average costs over 5 years were calculated for 46 endoscopic procedure-tiers. Results  Robust mean endoscopy costs ranged from 230.56 € for gastroscopy (144 666 cases), 276.23 € (n = 32 294) for a simple colonoscopy, to 844.07 € (n = 10 150) for ERCP with papillotomy and plastic stent insertion and 1602.37 € (n = 967) for ERCP with a self-expanding metal stent. Higher costs, specifically for complex procedures, were identified for University Hospitals. Discussion  For the first time this catalogue for endoscopic procedure-tiers, based on § 21 KHEntgG data-sets from 74 InEK-calculating hospitals, permits a realistic assessment of endoscopy costs in German hospitals. The higher costs in university hospitals are likely due to referral bias for complex cases and emergency interventions. For 46 endoscopic procedure-tiers an objective cost-allocation within the G-DRG system is now possible. By international comparison the costs of endoscopic procedures in Germany are low, due to either greater efficiency, lower personnel allocation or incomplete documentation of the real expenses. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion.

    PubMed

    Luo, Xiongbiao; Wan, Ying; He, Xiangjian

    2015-04-01

    Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization. The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor's) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm. The experimental results demonstrate that the authors' proposed method provides a more accurate and robust endoscopic guidance framework than state-of-the-art methods. The average guidance accuracy of the authors' framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29. A robust electromagnetically guided endoscopy framework was proposed on the basis of an enhanced particle swarm optimization method with using the current observation information and adaptive evolutionary factors. The authors proposed framework greatly reduced the guidance errors from (4.3, 7.8) to (3.0 mm, 5.6°), compared to state-of-the-art methods.

  10. Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes

    PubMed Central

    2012-01-01

    Background The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. Methods We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. Results The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). Conclusions Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not. PMID:22943739

  11. Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes.

    PubMed

    Chiu, King-Wah; Tsai, Ming-Chao; Wu, Keng-Liang; Chiu, Yi-Chun; Lin, Ming-Tzung; Hu, Tsung-Hui

    2012-09-03

    The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not.

  12. [The effect of laryngoscopic surgery combined with nasal endoscopic system for the treatment of vocal cords benign lesions].

    PubMed

    Wang, Weian; Lu, Rong

    2013-06-01

    To investigate the effect of laryngoscopic surgery combined with nasal endoscopic system for the treatment of vocal cords benign lesions. Fifty-two patients admitted to our department with vocal cords benign lesions (including vocal polyps, vocal nodules, vocal cord cyst) underwent laryngoscopic surgery combined with nasal endoscopic system. All patients were treated successfully once and for all without any significant postoperative complication. The laryngoscopic surgery combined with nasal endoscopic system is a safe, minimally invasive and simple method for the treatment of benign lesions of vocal cords.

  13. [Endoscopic sphincterotomy in choledocholithiasis and an intact gallbladder].

    PubMed

    Vladimirov, B; Petkov, R; Viiachki, I; Damianov, D; Iarŭmov, N

    1996-01-01

    Endoscopic sphincterotomy (ES) with extraction of calculi is a basic method of treating choledocholithiasis in post-cholecystectomy patients (8, 9). Endoscopic treatment contributes to a considerable reduction of the indications for reoperation. The existing views concerning ES done in patients with preserved gallbladder, especially in the era of laparoscopic surgery, are still conflicting (3, 6). There are several options: cholecystectomy with removal of calculi in the common bile duct by ES in a subsequent stage, or vice versa-primary ES with ensuring cholecystectomy. The undertaking of independent surgical or endoscopic treatment is likewise practicable (2, 6).

  14. [Successful endoscopic dilatation of a stenosis in relation to an ileorectal anastomosis by acute ileus].

    PubMed

    Kjærgaard, Jane Christensen; Hendel, Jakob; Gügenur, Ismail

    2014-02-17

    Endoscopic dilatation is a treatment option for patients with Crohns disease suffering from stenosis in relation to an ileorectal anastomosis. We present a case of a patient with Crohns disease who was admitted with acute obstructive symptoms due to a stensosis of the ileorectal anastomosis. The patient was septic. We performed a successful endoscopic dilatation in the acute phase and the patient was discharged few days after an uneventful recovery. Endoscopic dilatation of an ileorectal anastomsis in patients with Crohns disease is a treatment option in the acute setting when performed by experienced endoscopists.

  15. Endoscopic Optical Coherence Tomography for Clinical Gastroenterology

    PubMed Central

    Tsai, Tsung-Han; Fujimoto, James G.; Mashimo, Hiroshi

    2014-01-01

    Optical coherence tomography (OCT) is a real-time optical imaging technique that is similar in principle to ultrasonography, but employs light instead of sound waves and allows depth-resolved images with near-microscopic resolution. Endoscopic OCT allows the evaluation of broad-field and subsurface areas and can be used ancillary to standard endoscopy, narrow band imaging, chromoendoscopy, magnification endoscopy, and confocal endomicroscopy. This review article will provide an overview of the clinical utility of endoscopic OCT in the gastrointestinal tract and of recent achievements using state-of-the-art endoscopic 3D-OCT imaging systems. PMID:26852678

  16. Paediatric Gastrointestinal Endoscopy: European Society for Paediatric Gastroenterology Hepatology and Nutrition and European Society of Gastrointestinal Endoscopy Guidelines.

    PubMed

    Thomson, Mike; Tringali, Andrea; Dumonceau, Jean-Marc; Tavares, Marta; Tabbers, Merit M; Furlano, Raoul; Spaander, Manon; Hassan, Cesare; Tzvinikos, Christos; Ijsselstijn, Hanneke; Viala, Jérôme; Dall'Oglio, Luigi; Benninga, Marc; Orel, Rok; Vandenplas, Yvan; Keil, Radan; Romano, Claudio; Brownstone, Eva; Hlava, Štěpán; Gerner, Patrick; Dolak, Werner; Landi, Rosario; Huber, Wolf D; Everett, Simon; Vecsei, Andreas; Aabakken, Lars; Amil-Dias, Jorge; Zambelli, Alessandro

    2017-01-01

    This guideline refers to infants, children, and adolescents ages 0 to 18 years. The areas covered include indications for diagnostic and therapeutic esophagogastroduodenoscopy and ileocolonoscopy; endoscopy for foreign body ingestion; corrosive ingestion and stricture/stenosis endoscopic management; upper and lower gastrointestinal bleeding; endoscopic retrograde cholangiopancreatography; and endoscopic ultrasonography. Percutaneous endoscopic gastrostomy and endoscopy specific to inflammatory bowel disease has been dealt with in other guidelines and are therefore not mentioned in this guideline. Training and ongoing skill maintenance are to be dealt with in an imminent sister publication to this.

  17. Endoscopic therapy for early gastric cancer: Standard techniques and recent advances in ESD

    PubMed Central

    Kume, Keiichiro

    2014-01-01

    The technique of endoscopic submucosal dissection (ESD) is now a well-known endoscopic therapy for early gastric cancer. ESD was introduced to resect large specimens of early gastric cancer in a single piece. ESD can provide precision of histologic diagnosis and can also reduce the recurrence rate. However, the drawback of ESD is its technical difficulty, and, consequently, it is associated with a high rate of complications, the need for advanced endoscopic techniques, and a lengthy procedure time. Various advances in the devices and techniques used for ESD have contributed to overcoming these drawbacks. PMID:24914364

  18. Accidental hijab pin ingestion in Muslim women: an emerging endoscopic emergency?

    PubMed

    Goh, Jason; Patel, Neeral; Boulton, Ralph

    2014-01-03

    Ingested foreign body is an infrequent indication for emergency endoscopy in the adult gastroenterology practice. We describe the clinical features and endoscopic management of the first four cases of accidental ingestion of hijab pins by Muslim women in our unit, all presenting within a 12-month period. The pins were all successfully retrieved without any complications. In this report, we review published guidelines and the current literature, as well as discussing the approach (conservative vs proactive endoscopic retrieval) and timing of endoscopic treatment. The Muslim community may need to be alerted to the potential health hazard of hijab pins.

  19. Capsule endoscope localization based on computer vision technique.

    PubMed

    Liu, Li; Hu, Chao; Cai, Wentao; Meng, Max Q H

    2009-01-01

    To build a new type of wireless capsule endoscope with interactive gastrointestinal tract examination, a localization and orientation system is needed for tracking 3D location and 3D orientation of the capsule movement. The magnetic localization and orientation method produces only 5 DOF, but misses the information of rotation angle along capsule's main axis. In this paper, we presented a complementary orientation approach for the capsule endoscope, and the 3D rotation can be determined by applying computer vision technique on the captured endoscopic images. The experimental results show that the complementary orientation method has good accuracy and high feasibility.

  20. Ultrahigh sensitivity endoscopic camera using a new CMOS image sensor: providing with clear images under low illumination in addition to fluorescent images.

    PubMed

    Aoki, Hisae; Yamashita, Hiromasa; Mori, Toshiyuki; Fukuyo, Tsuneo; Chiba, Toshio

    2014-11-01

    We developed a new ultrahigh-sensitive CMOS camera using a specific sensor that has a wide range of spectral sensitivity characteristics. The objective of this study is to present our updated endoscopic technology that has successfully integrated two innovative functions; ultrasensitive imaging as well as advanced fluorescent viewing. Two different experiments were conducted. One was carried out to evaluate the function of the ultrahigh-sensitive camera. The other was to test the availability of the newly developed sensor and its performance as a fluorescence endoscope. In both studies, the distance from the endoscopic tip to the target was varied and those endoscopic images in each setting were taken for further comparison. In the first experiment, the 3-CCD camera failed to display the clear images under low illumination, and the target was hardly seen. In contrast, the CMOS camera was able to display the targets regardless of the camera-target distance under low illumination. Under high illumination, imaging quality given by both cameras was quite alike. In the second experiment as a fluorescence endoscope, the CMOS camera was capable of clearly showing the fluorescent-activated organs. The ultrahigh sensitivity CMOS HD endoscopic camera is expected to provide us with clear images under low illumination in addition to the fluorescent images under high illumination in the field of laparoscopic surgery.

  1. [Experience of Fusion image guided system in endonasal endoscopic surgery].

    PubMed

    Wen, Jingying; Zhen, Hongtao; Shi, Lili; Cao, Pingping; Cui, Yonghua

    2015-08-01

    To review endonasal endoscopic surgeries aided by Fusion image guided system, and to explore the application value of Fusion image guided system in endonasal endoscopic surgeries. Retrospective research. Sixty cases of endonasal endoscopic surgeries aided by Fusion image guided system were analysed including chronic rhinosinusitis with polyp (n = 10), fungus sinusitis (n = 5), endoscopic optic nerve decompression (n = 16), inverted papilloma of the paranasal sinus (n = 9), ossifying fibroma of sphenoid bone (n = 1), malignance of the paranasal sinus (n = 9), cerebrospinal fluid leak (n = 5), hemangioma of orbital apex (n = 2) and orbital reconstruction (n = 3). Sixty cases of endonasal endoscopic surgeries completed successfully without any complications. Fusion image guided system can help to identify the ostium of paranasal sinus, lamina papyracea and skull base. Fused CT-CTA images, or fused MR-MRA images can help to localize the optic nerve or internal carotid arteiy . Fused CT-MR images can help to detect the range of the tumor. It spent (7.13 ± 1.358) minutes for image guided system to do preoperative preparation and the surgical navigation accuracy reached less than 1mm after proficient. There was no device localization problem because of block or head set loosed. Fusion image guided system make endonasal endoscopic surgery to be a true microinvasive and exact surgery. It spends less preoperative preparation time, has high surgical navigation accuracy, improves the surgical safety and reduces the surgical complications.

  2. Predictive factors suggesting an underestimation of gastric lesions initially diagnosed as adenomas by forceps biopsy.

    PubMed

    Ko, Sung Jun; Yang, Min A; Yun, So Hee; Park, Moon Sik; Han, Shang Hoon; Cho, Jin Woong

    2016-03-01

    The endoscopic forceps biopsy of gastric lesion may provide inadequate specimens for a correct diagnosis of the entire lesion. Therefore, a histologic discrepancy may exist between specimens obtained by forceps biopsy and by endoscopic resection. The aim of this study was to evaluate the endoscopic characteristics of an underestimation in gastric carcinomas initially diagnosed as adenomas by forceps biopsy. We retrospectively reviewed 431 lesions diagnosed as gastric adenomas by forceps biopsy and resected by endoscopic submucosal dissection (ESD) between January 2008 and December 2011. The endoscopic findings were reviewed for location, size, gross appearance, ulceration, and surface color. We compared these variables between the adenoma group and the carcinoma group, as defined by the post-resection pathological findings. The mean patient age was 65.63±9.30 years in the adenoma group and 64.75±10.30 years in the carcinoma group. The mean size of the lesion was 21.04±8.65 mm in the adenoma group and 22.06±7.46 mm in the carcinoma group. In the multivariate analysis, high-grade dysplasia from endoscopic forceps biopsy and red discoloration were significant variables associated with carcinoma in post-resection histology. Gastric adenomatous lesions with endoscopic characteristics of surface redness and high-grade dysplasia on forceps biopsy should be resected completely by ESD because of the high possibility of an underestimation after ESD.

  3. Dual-Channel Endoscopic Indocyanine Green Fluorescence Angiography for Clipping of Cerebral Aneurysms.

    PubMed

    Cho, Won-Sang; Kim, Jeong Eun; Kang, Hyun-Seung; Ha, Eun Jin; Jung, Minwoong; Lee, Choonghee; Shin, Il Hyung; Kang, Uk

    2017-04-01

    Neuroendoscopy is useful for assessing status of perforators, parent arteries, and aneurysms beyond the straight line of microscopic view during aneurysm clipping. We aimed to evaluate the clinical usefulness of our endoscopic indocyanine green angiography (ICGA) system, which can simultaneously display visible light and indocyanine green fluorescent images. Surgical clipping of 16 unruptured aneurysms in 10 patients was performed via the keyhole approach. Using our endoscopic ICGA and commercial microscopic ICGA systems, we prospectively compared 10 targeted cerebral aneurysms at the posterior communicating (n = 4) and anterior choroidal (n = 6) arteries. Microscopic ICGA and endoscopic ICGA were feasible during surgery. Microscopic ICGA displayed 50% of branch orifices, 100% of branch trunks, and 20% of exact clip positions, whereas endoscopic ICGA showed 100% of these. Based on endoscopic ICGA findings such as incomplete clipping and compromise of parent arteries or branches, clips were repositioned in 2 cases, and additional clips were applied in 2 cases. Complete occlusion and residual neck states were achieved in 6 and 4 aneurysms after surgery. There were no neurologic deficits within 3 months after surgery except for frontalis palsy and anosmia in each patient. The endoscopic ICGA system with dual imaging of visible light and indocyanine green fluorescence was very useful for assessing geometry of aneurysms and surrounding vessels before clipping and for evaluating completeness of clip position after clipping. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Optimal Timing for Laparoscopic Cholecystectomy After Endoscopic Retrograde Cholangiopancreatography: A Systematic Review.

    PubMed

    Friis, C; Rothman, J P; Burcharth, J; Rosenberg, J

    2018-06-01

    Endoscopic retrograde cholangiopancreatography followed by laparoscopic cholecystectomy is often used as definitive treatment for common bile duct stones. The aim of this study was to investigate the optimal time interval between endoscopic retrograde cholangiopancreatography and laparoscopic cholecystectomy. PubMed and Embase were searched for studies comparing different time delays between endoscopic retrograde cholangiopancreatography and laparoscopic cholecystectomy. Observational studies and randomized controlled trials were included. Primary outcome was conversion rate from laparoscopic to open cholecystectomy and secondary outcomes were complications, mortality, operating time, and length of stay. A total of 14 studies with a total of 1930 patients were included. The pooled estimate revealed an increase from a 4.2% conversion rate when laparoscopic cholecystectomy was performed within 24 h of endoscopic retrograde cholangiopancreatography to 7.6% for 24-72 h delay to 12.3% when performed within 2 weeks, to 12.3% for 2-6 weeks, and to a 14% conversion rate when operation was delayed more than 6 weeks. According to this systematic review, it is preferable to perform cholecystectomy within 24 h of endoscopic retrograde cholangiopancreatography to reduce conversion rate. Early laparoscopic cholecystectomy does not increase mortality, perioperative complications, or length of stay and on the contrary it reduces the risk of reoccurrence and progression of disease in the delay between endoscopic retrograde cholangiopancreatography and laparoscopic cholecystectomy.

  5. Multiband mucosectomy for advanced dysplastic lesions in the upper digestive tract

    PubMed Central

    Espinel, Jesús; Pinedo, Eugenia; Ojeda, Vanesa; del Rio, Maria Guerra

    2015-01-01

    Endoscopic resection (ER) is at present an accepted treatment for superficial gastrointestinal neoplasia. ER provides similar efficacy to surgery; however, it is minimally invasive and less expensive. Endoscopic mucosal resection (EMR) is superior to biopsy for diagnosing advanced dysplasia and can change the diagnostic grade and the management. Several EMR techniques have been described that are alternatively used dependent upon the endoscopist personal experience, the anatomic conditions and the endoscopic appearance of the lesion to be resected. The literature suggests that EMR offers comparable outcomes to surgery for selected indications. EMR techniques using a cap fitted endoscope and EMR using a ligation device [multiband mucosectomy (MBM)] are the most frequently use. MBM technique does not require submucosal injection as with the endoscopic resection-cap technique, multiple resections can be performed with the same snare, pre-looping the endoscopic resection-snare in the ridge of the cap is not necessary, MBM does not require withdrawal of the endoscope between resections and up to six consecutive resections can be performed. This reduces the time and cost required for the procedure, while also reducing patient discomfort. Despite the increasing popularity of MBM, data on the safety and efficacy of this technique in upper gastrointestinal lesions with advanced dysplasia, defined as those lesions that have high-grade dysplasia or early cancer, is limited. PMID:25901216

  6. An examination of the relationship between the endoscopic appearance of duodenitis and the histological findings in patients with epigastric pain.

    PubMed

    Lewis, Stephen; Stableforth, William; Awasthi, Rachana; Awasthi, Ashish; Pitts, Narrie; Ottaway, Janet; Sherwood, Anthea; Robertson, Neil; Cochrane, Sean; Wilkinson, Stephen

    2012-01-01

    The endoscopic appearance of duodenitis is a common finding in patients undergoing endoscopy because of epigastric pain however, the relationship of the visual findings to histology is poorly defined. We set out to ascertain if there was a correlation between the endoscopic and histological appearances of the duodenal mucosa. Consecutive patients with epigastric pain referred for diagnostic gastroduodenoscopy were studied. The visual appearances of 'duodenitis' (erythema, erosions and sub-epithelial haemorrhage) were reported independently by two endoscopists. Duodenal biopsies were taken and assessed for: neutrophil infiltrate, mononuclear infiltrate, gastric metaplasia, villous atrophy and a breach in the mucosa. H pylori status was determined. Of the 93 patients with endoscopic features of duodenitis an increase in histological markers of inflammation was found in 75 (81%). However, histological inflammation was absent or minimal in 68 (73%). Conversely, biopsies from normal-looking mucosa revealed histological evidence of inflammation in 26 (27%). For patients with the endoscopic features of duodenitis the positive & negative predictive value for neutrophilic infiltrate was 39% and 98% respectively. Biopsies from erosions confirmed a breach in the mucosa in only 2 of 40 patients. Neutrophilic infiltrate occurred with NSAI ingestion and infection with H pylori. The endoscopic appearance of the duodenal mucosa is unreliable in determining the presence of histological inflammation. The endoscopic appearance of 'erosions' is not usually associated with a mucosal breach.

  7. Gynaecological endoscopic surgical education and assessment. A diploma programme in gynaecological endoscopic surgery.

    PubMed

    Campo, Rudi; Wattiez, Arnaud; Tanos, Vasilis; Di Spiezio Sardo, Attilio; Grimbizis, Grigoris; Wallwiener, Diethelm; Brucker, Sara; Puga, Marco; Molinas, Roger; O'Donovan, Peter; Deprest, Jan; Van Belle, Yves; Lissens, Ann; Herrmann, Anja; Tahir, Mahmood; Benedetto, Chiara; Siebert, Igno; Rabischong, Benoit; De Wilde, Rudy Leon

    In recent years, training and education in endoscopic surgery has been critically reviewed. Clinicians, both surgeons as gynaecologist who perform endoscopic surgery without proper training of the specific psychomotor skills, are at higher risk to increased patient morbidity and mortality. Although the apprentice-tutor model has long been a successful approach for training of surgeons, recently, clinicians have recognised that endoscopic surgery requires an important training phase outside the operating theatre. The Gynaecological Endoscopic Surgical Education and Assessment programme (GESEA) recognises the necessity of this structured approach and implements two separated stages in its learning strategy. In the first stage, a skill certificate on theoretical knowledge and specific practical psychomotor skills is acquired through a high-stake exam; in the second stage, a clinical programme is completed to achieve surgical competence and receive the corresponding diploma. Three diplomas can be awarded: (a) the Bachelor in Endoscopy, (b) the Minimally Invasive Gynaecological Surgeon (MIGS) and (c) the Master level. The Master level is sub-divided into two separate diplomas: the Master in Laparoscopic Pelvic Surgery and the Master in Hysteroscopy. The complexity of modern surgery has increased the demands and challenges to surgical education and the quality control. This programme is based on the best available scientific evidence, and it counteracts the problem of the traditional surgical apprentice-tutor model. It is seen as a major step toward standardisation of endoscopic surgical training in general.

  8. Ultrathin endoscopes based on multicore fibers and adaptive optics: a status review and perspectives.

    PubMed

    Andresen, Esben Ravn; Sivankutty, Siddharth; Tsvirkun, Viktor; Bouwmans, Géraud; Rigneault, Hervé

    2016-12-01

    We take stock of the progress that has been made into developing ultrathin endoscopes assisted by wave front shaping. We focus our review on multicore fiber-based lensless endoscopes intended for multiphoton imaging applications. We put the work into perspective by comparing with alternative approaches and by outlining the challenges that lie ahead.

  9. Safety and Efficacy of Endoscopic Therapy for Nonmalignant Duodenal Duplication Cysts: Case Report and Comprehensive Review of 28 Cases Reported in the Literature.

    PubMed

    Gjeorgjievski, Mihajlo; Manickam, Palaniappan; Ghaith, Gehad; Cappell, Mitchell S

    2016-05-01

    Analyze efficacy, safety of endoscopic therapy for duodenal duplication cysts (DDC) by comprehensively reviewing case reports.Tandem, independent, systematic, computerized, literature searches were performed via PubMed using medical subject headings or Keywords "cyst" and "duodenal" and "duplication"; or "cyst", and "endoscopy" or "endoscopic", and "therapy" or "decompression"; with reconciliation of generated references by two experts. Case report followed CARE guidelines.Literature review revealed 28 cases (mean = 1.3 ± 1.2 cases/report). Endoscopic therapy is increasingly reported recently (1984-1999: 3 cases, 2000-2015: 25 cases, P = 0.003, OR = 8.33, 95%-CI: 1.77-44.5). Fourteen (54%) of 26 patients were men (unknown-sex = 2). Mean age = 32.2 ± 18.3 years old. Procedure indications: acute pancreatitis-16, abdominal pain-8, jaundice-2, gastrointestinal (GI) obstruction-1, asymptomatic cyst-1. Mean maximal DDC dimension = 3.20 ± 1.53 cm (range, 1-6.5 cm). Endoscopic techniques included cyst puncture via needle knife papillotomy (NKP)/papillotome-18, snare resection of cyst-7, cystotome-2, and cyst needle aspiration/ligation-1. Endoscopic therapy was successful in all cases. Among 24 initially symptomatic patients, all remained asymptomatic post-therapy without relapses (mean follow-up = 36.5 ± 48.6 months, 3 others reported asymptomatic at follow-up of unknown duration; 1 initially asymptomatic patient remained asymptomatic 3 years post-therapy). Two complications occurred: mild intraprocedural duodenal bleeding related to NKP and treated locally endoscopically.A patient is reported who presented with vomiting, 15-kg-weight-loss, and profound dehydration for 1 month from extrinsic compression of duodenum by 14 × 6 cm DDC, underwent successful endosonographic cyst decompression with large fenestration of cyst and endoscopic aspiration of 1 L of fluid from cyst with rapid relief of symptoms. At endoscopy the DDC was intubated and visualized and random endoscopic mucosal biopsies were obtained to help exclude malignant or dysplastic DDC.Study limitations include retrospective literature review, potential reporting bias, limited patient number, variable follow-up.In conclusion, endoscopic therapy for DDC was efficacious in all 29 reported patients including current case, including patients presenting acutely with acute pancreatitis, or GI obstruction. Complications were rare and minor, suggesting that endoscopic therapy may be a useful alternative to surgery for nonmalignant DDC when performed by expert endoscopists.

  10. A new rapid quantitative test for fecal calprotectin predicts endoscopic activity in ulcerative colitis.

    PubMed

    Lobatón, Triana; Rodríguez-Moranta, Francisco; Lopez, Alicia; Sánchez, Elena; Rodríguez-Alonso, Lorena; Guardiola, Jordi

    2013-04-01

    Fecal calprotectin (FC) determined by the enzyme-linked immunosorbent assay (ELISA) test has been proposed as a promising biomarker of endoscopic activity in ulcerative colitis (UC). However, data on its accuracy in predicting endoscopic activity is scarce. Besides, FC determined by the quantitative-point-of-care test (FC-QPOCT) that provides rapid and individual results could optimize its use in clinical practice. The aims of our study were to evaluate the ability of FC to predict endoscopic activity according to the Mayo score in patients with UC when determined by FC-QPOCT and to compare it with the ELISA test (FC-ELISA). FC was determined simultaneously by FC-ELISA and FC-QPOCT in patients with UC undergoing colonoscopy. Clinical disease activity and endoscopy were assessed according to the Mayo score. Blood tests were taken to analyze serological biomarkers. A total of 146 colonoscopies were performed on 123 patients with UC. FC-QPOCT correlated more closely with the Mayo endoscopic subscore (Spearman's correlation coefficient rank r = 0.727, P < 0.001) than clinical activity (r = 0.636, P < 0.001), platelets (r = 0.381, P < 0.001), leucocytes (r = 0.300, P < 0.001), and C-reactive protein (r = 0.291, P = 0.002). The prediction of "endoscopic remission" (Mayo endoscopic subscore ≤1) with FC-QPOCT (280 µg/g) and FC-ELISA (250 µg/g) presented an area under the curve of 0.906 and 0.924, respectively. The interclass correlation index between both tests was 0.904 (95% confidence interval, 0.864-0.932; P < 0.001). FC determined by QPOCT was an accurate surrogate marker of "endoscopic remission" in UC and presented a good correlation with the FC-ELISA test.

  11. Development of innovative techniques for the endoscopic implantation and securing of a novel, wireless, miniature gastrostimulator (with videos)

    PubMed Central

    Deb, Sanchali; Tang, Shou-jiang; Abell, Thomas L.; McLawhorn, Tyler; Huang, Wen-Ding; Lahr, Christopher; To, S.D. Filip; Easter, Julie; Chiao, J.-C.

    2016-01-01

    Background Gastric stimulation via high-frequency, low-energy pulses can provide an effective treatment for gastric dysmotility; however, the current commercially available device requires surgical implantation for long-term stimulation and is powered by a nonrechargeable battery. Objective To test and describe endoscopic implantation techniques and testing of stimulation of a novel, wireless, batteryless, gastric electrical stimulation (GES) device. Design Endoscopic gastric implantation techniques were implemented, and in vivo gastric signals were recorded and measured in a non-survival swine model (n = 2; 50-kg animals). Intervention Five novel endoscopic gastric implantation techniques and stimulation of a novel, wireless, batteryless, GES device were tested on a non-survival swine model. Main Outcome Measurements Feasibility of 5 new endoscopic gastric implantation techniques of the novel, miniature, batteryless, wireless GES device while recording and measurement of in vivo gastric signals. Results All 5 of the novel endoscopic techniques permitted insertion and securing of the miniaturized gastrostimulator. By the help of these methods and miniaturization of the gastrostimulator, successful GES could be provided without any surgery. The metallic clip attachment was restricted to the mucosal surface, whereas the prototype tacks, prototype spring coils, percutaneous endoscopic gastrostomy wires/T-tag fasteners, and submucosal pocket endoscopic implantation methods attach the stimulator near transmurally or transmurally to the stomach. They allow more secure device attachment with optimal stimulation depth. Limitations Non-survival pig studies. Conclusion These 5 techniques have the potential to augment the utility of GES as a treatment alternative, to provide an important prototype for other dysmotility treatment paradigms, and to yield insights for new technological interfaces between non-invasiveness and surgery. PMID:22726478

  12. Craniotomy with endoscopic assistance in the treatment of nasopharygeal fibroangioma.

    PubMed

    Fu, Ji-di; Liu, Hao-cheng; Zhao, Shang-feng; Zhang, Jia-liang; Li, Yong; Ni, Xin; Yu, Chun-jiang

    2010-05-20

    Nasopharygeal fibroangioma (NPF) can be approached through lateral rhinotomy, the middle skull fossa approach and the transcranial-facial combined approach. It is complicated and thus results in more insults, and when adopted, the total resection rate of tumor is still low. The nasal endoscope is minimally invasive, the dead angles of a craniotomy, such as sphenoid sinus, maxillary sinus, and nasopharynx are easily approached by an endoscope. Lateral rhinotomy have to make facial incision and affects maxillary bone development. We combined the craniotomy and endoscopic approach intending to take advantages of the two approaches. Twelve NPF patients who underwent craniotomy with endoscopic assistance from March 2002 to July 2008 at the Beijing Tongren Hospital were selected. All patients were male. Their ages ranged from 11 to 33 years. The main symptoms were visual deterioration, exophthalmos, nasal obstruction, epistaxis and pharynx nasalis neoplasm. The diagnosis was based on CT, MRI and digital subtraction angiography (DSA). All patients had intracranial encroachment and all underwent DSA and embolism treatment were taken before surgery. Seven patients had a pterional craniotomy, five had a frontal-temporal-orbital-zygomatic craniotomy. Most of the tumor was resected piecemeal, then removed through the sphenoidal sinus. Finally, using an endoscope in the nasal cavity, tumor in nasal cavity was resected and removed through the sphenoidal sinus, observing the dead angle of the craniotomy and confirming that sinus drainage was unobstructed. The tumor was removed completely in 11 patients and partially resected in one patient because of hemorrhage. One patient had an infection after the operation and one patient had cerebrospinal rhinorrhea 3 years after surgery that was remediated by endoscopic repair. Craniotomy with endoscopic assistance in the treatment of NPF was minimally invasive, safe and efficient, and avoided facial incision.

  13. Submucosal tunnel endoscopy: Peroral endoscopic myotomy and peroral endoscopic tumor resection

    PubMed Central

    Eleftheriadis, Nikolas; Inoue, Haruhiro; Ikeda, Haruo; Onimaru, Manabu; Maselli, Roberta; Santi, Grace

    2016-01-01

    Peroral endoscopic myotomy (POEM) is an innovative, minimally invasive, endoscopic treatment for esophageal achalasia and other esophageal motility disorders, emerged from the natural orifice transluminal endoscopic surgery procedures, and since the first human case performed by Inoue in 2008, showed exciting results in international level, with more than 4000 cases globally up to now. POEM showed superior characteristics than the standard 100-year-old surgical or laparoscopic Heller myotomy (LHM), not only for all types of esophageal achalasia [classical (I), vigorous (II), spastic (III), Chicago Classification], but also for advanced sigmoid type achalasia (S1 and S2), failed LHM, or other esophageal motility disorders (diffuse esophageal spasm, nutcracker esophagus or Jackhammer esophagus). POEM starts with a mucosal incision, followed by submucosal tunnel creation crossing the esophagogastric junction (EGJ) and myotomy. Finally the mucosal entry is closed with endoscopic clip placement. POEM permitted relatively free choice of myotomy length and localization. Although it is technically demanding procedure, POEM can be performed safely and achieves very good control of dysphagia and chest pain. Gastroesophageal reflux is the most common troublesome side effect, and is well controllable with proton pump inhibitors. Furthermore, POEM opened the era of submucosal tunnel endoscopy, with many other applications. Based on the same principles with POEM, in combination with new technological developments, such as endoscopic suturing, peroral endoscopic tumor resection (POET), is safely and effectively applied for challenging submucosal esophageal, EGJ and gastric cardia tumors (submucosal tumors), emerged from muscularis propria. POET showed up to know promising results, however, it is restricted to specialized centers. The present article reviews the recent data of POEM and POET and discussed controversial issues that need further study and future perspectives. PMID:26839649

  14. Endoscopic Therapy for Achalasia Before Heller Myotomy Results in Worse Outcomes Than Heller Myotomy Alone

    PubMed Central

    Smith, C Daniel; Stival, Alessandro; Howell, D Lee; Swafford, Vickie

    2006-01-01

    Objective: Heller myotomy has been shown to be an effective primary treatment of achalasia. However, many physicians treating patients with achalasia continue to offer endoscopic therapies before recommending operative myotomy. Herein we report outcomes in 209 patients undergoing Heller myotomy with the majority (74%) undergoing myotomy as secondary treatment of achalasia. Methods: Data on all patients undergoing operative management of achalasia are collected prospectively. Over a 9-year period (1994–2003), 209 patients underwent Heller myotomy for achalasia. Of these, 154 had undergone either Botox injection and/or pneumatic dilation preoperatively. Preoperative, operative, and long-term outcome data were analyzed. Statistical analysis was performed with multiple χ2 and Mann-Whitney U analyses, as well as ANOVA. Results: Among the 209 patients undergoing Heller myotomy for achalasia, 154 received endoscopic therapy before being referred for surgery (100 dilation only, 33 Botox only, 21 both). The groups were matched for preoperative demographics and symptom scores for dysphagia, regurgitation, and chest pain. Intraoperative complications were more common in the endoscopically treated group with GI perforations being the most common complication (9.7% versus 3.6%). Postoperative complications, primarily severe dysphagia, and pulmonary complications were more common after endoscopic treatment (10.4% versus 5.4%). Failure of myotomy as defined by persistent or recurrent severe symptoms, or need for additionally therapy including redo myotomy or esophagectomy was higher in the endoscopically treated group (19.5% versus 10.1%). Conclusion: Use of preoperative endoscopic therapy remains common and has resulted in more intraoperative complications, primarily perforation, more postoperative complications, and a higher rate of failure than when no preoperative therapy was used. Endoscopic therapy for achalasia should not be used unless patients are not candidates for surgery. PMID:16632991

  15. Transoral endoscopic esophageal myotomy based on esophageal function testing in a survival porcine model.

    PubMed

    Perretta, Silvana; Dallemagne, Bernard; Donatelli, Gianfranco; Diemunsch, Pierre; Marescaux, Jacques

    2011-01-01

    The most effective treatment of achalasia is Heller myotomy. To explore a submucosal endoscopic myotomy technique tailored on esophageal physiology testing and to compare it with the open technique. Prospective acute and survival comparative study in pigs (n = 12; 35 kg). University animal research center. Eight acute-4 open and 4 endoscopic-myotomies followed by 4 survival endoscopic procedures. Preoperative and postoperative manometry; esophagogastric junction (EGJ) distensibility before and after selective division of muscular fibers at the EGJ and after the myotomy was prolonged to a standard length by using the EndoFLIP Functional Lumen Imaging Probe (Crospon, Galway, Ireland). All procedures were successful, with no intraoperative and postoperative complications. In the survival group, the animals recovered promptly from surgery. Postoperative manometry demonstrated a 50% drop in mean lower esophageal sphincter pressure (LESp) in the endoscopic group (mean preoperative LESp, 22.2 ± 3.3 mm Hg; mean postoperative LESp, 11.34 ± 2.7 mm Hg; P < .005) and a 69% loss in the open procedure group (mean preoperative LESp, 24.2 ± 3.2 mm Hg; mean postoperative LESp, 7.4 ± 4 mm Hg; P < .005). The EndoFLIP monitoring did not show any distensibility difference between the 2 techniques, with the main improvement occurring when the clasp circular fibers were taken. Healthy animal model; small sample. Endoscopic submucosal esophageal myotomy is feasible and safe. The lack of a significant difference in EGJ distensibility between the open and endoscopic procedure is very appealing. Were it to be perfected in a human population, this endoscopic approach could suggest a new strategy in the treatment of selected achalasia patients. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  16. [Microbiological investigation of endoscopes at Brest Hospital over a period from 2007 to 2009].

    PubMed

    Saliou, P; Garlantézec, R; Baron, R; Quiot, J-J; Cholet, F; Le Floch, M-F; Lejeune, B

    2011-04-01

    The aim of this study is to evaluate the quality of disinfection of endoscopes at Brest hospital over a period from 2007 to 2009. Retrospective study of microbiological investigations of endoscopes done at Brest hospital from 2007 to 2009. The interpretation of the microbiological investigations is based on the recommendations of the Comité technique national des infections nosocomiales et infections liées aux soins (CTINILS) of 2007. Most of the controls realized over the period deal with gastroenterological endoscopes (63.4 %) and bronchial endoscopes (21.8 %). Most of the controls (66.8 %) are conformed to the target level. Only 26.7 % of the controls get the level of action. Globally, the rate of level of action significantly increases (p=0.004) from 2007 (21.2 %) to 2009 (35.6 %). This increase is relatively important in gastroenterology endoscopy (46.8 % in 2009 versus 24.1 % in 2007) whereas the rate decreases in bronchial endoscopy (14.8 % in 2009 versus 25.9 % in 2007). In gastroenterological endoscopy, rates vary with the type of endoscopes and the context of controls, but there is no significant difference between manual disinfection and automated disinfection. The most frequent germ found in gastroenterological and bronchial endoscopies is Pseudomonas aeruginosa. Our results show that it is very difficult to insure a perfect disinfection of endoscopes. Difficulties met are certainly related with the complexity of the endoscopes and of the techniques of disinfection. Infections of patients are very infrequent in endoscopy, which takes the question of the pertinence of the threshold used for microbiological investigations. Copyright © 2010. Published by Elsevier SAS.

  17. Serum ficolin-2 correlates worse than fecal calprotectin and CRP with endoscopic Crohn's disease activity.

    PubMed

    Schaffer, Thomas; Schoepfer, Alain M; Seibold, Frank

    2014-09-01

    Ficolin-2 is an acute phase reactant produced by the liver and targeted to recognize N-acetyl-glucosamine which is present in bacterial and fungal cell walls. We recently showed that ficolin-2 serum levels were significantly higher in CD patients compared to healthy controls. We aimed to evaluate serum ficolin-2 concentrations in CD patients regarding their correlation with endoscopic severity and to compare them with clinical activity, fecal calprotectin, and CRP. Patients provided fecal and blood samples before undergoing ileo-colonoscopy. Disease activity was scored clinically according to the Harvey-Bradshaw Index (HBI) and endoscopically according to the simplified endoscopic score for CD (SES-CD). Ficolin-2 serum levels and fecal calprotectin levels were measured by ELISA. A total of 136 CD patients were prospectively included (mean age at inclusion 41.5±15.4 years, 37.5% females). Median HBI was 3 [2-6] points, median SES-CD was 5 [2-8], median fecal calprotectin was 301 [120-703] μg/g, and median serum ficolin-2 was 2.69 [2.02-3.83] μg/mL. SES-CD correlated significantly with calprotectin (R=0.676, P<0.001), CRP (R=0.458, P<0.001), HBI (R=0.385, P<0.001), and serum ficolin-2 levels (R=0.171, P=0.047). Ficolin-2 levels were higher in CD patients with mild endoscopic disease compared to patients in endoscopic remission (P=0.015) but no difference was found between patients with mild, moderate, and severe endoscopic disease. Ficolin-2 serum levels correlate worse with endoscopic CD activity when compared to fecal calprotectin or CRP. Copyright © 2014 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.

  18. Correlation of immunohistochemical mismatch repair protein status between colorectal carcinoma endoscopic biopsy and resection specimens.

    PubMed

    O'Brien, Odharnaith; Ryan, Éanna; Creavin, Ben; Kelly, Michael E; Mohan, Helen M; Geraghty, Robert; Winter, Des C; Sheahan, Kieran

    2018-02-01

    Microsatellite instability is reflective of a deficient mismatch repair system (dMMR), which may be due to either sporadic or germline mutations in the relevant mismatch repair (MMR) gene. MMR status is frequently determined by immunohistochemistry (IHC) for mismatch repair proteins (MMRPs) on colorectal cancer (CRC) resection specimens. However, IHC testing performed on endoscopic biopsy may be as reliable as that performed on surgical resections. We aimed to evaluate the reliability of MMR IHC staining on preoperative CRC endoscopic biopsies compared with matched-surgical resection specimens. A retrospective search of our institution's histopathology electronic database was performed. Patients with CRC who had MMR IHC performed on both their preoperative endoscopic biopsy and subsequent resection from January 2010 to January 2016 were included. Concordance of MMR staining between biopsy and resection specimens was assessed. From 2000 to 2016, 53 patients had MMR IHC performed on both their preoperative colorectal endoscopic biopsy and resection specimens; 10 patients (18.87%) demonstrated loss of ≥1 MMRP on their initial endoscopic tumour biopsy. The remainder (81.13%) showed preservation of staining for all MMRPs. There was complete agreement in MMR IHC status between the preoperative endoscopic biopsies and corresponding resection specimens in all cases (κ=1.000, P<0.000) with a sensitivity of 100% (95% CI 69.15 to 100) and specificity of 100% (95% CI 91.78 to 100) for detection of dMMR. Endoscopic biopsies are a suitable source of tissue for MMR IHC analysis. This may provide a number of advantages to both patients and clinicians in the management of CRC. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. High Regional Variation in Urethroplasty in the United States

    PubMed Central

    Figler, Bradley D.; Gore, John L.; Holt, Sarah K.; Voelzke, Bryan B.; Wessells, Hunter

    2015-01-01

    Purpose We identified clinical and regional factors associated with the use of urethroplasty vs repeat endoscopic management for urethral stricture disease. Materials and Methods We analyzed claims for patients 18 to 65 years old in the 2007 to 2011 MarketScan ® Commercial Claims and Encounters Database with a diagnosis of urethral stricture. The primary outcome was treatment with urethroplasty vs repeat endoscopic management, defined as more than 2 dilations or direct vision internal urethrotomies. The likelihood of urethroplasty vs repeat endoscopic management was determined for each major metropolitan area in the United States. Multivariate logistic regression was done to identify factors associated with urethroplasty. Results We identified 41,056 patients with urethral stricture, yielding a diagnosis rate of 296/100,000 men in MarketScan. Repeat endoscopic management and urethroplasty were performed in 2,700 and 1,444 patients, respectively. Compared to patients treated with repeat endoscopic management those with urethroplasty were younger (median age 44 vs 54 years) and more likely to have a Charlson comorbidity score of 0 (84% vs 77%), have traveled out of a metropolitan area for care (34% vs 17%) and have a reconstructive urologist in the treatment metropolitan area (76% and 62%, each p < 0.001). When controlling for age and Charlson comorbidity score, travel out of a metropolitan area (OR 2.7, 95% CI 2.2–3.3) and a reconstructive urologist in the treatment metropolitan area (OR 2.0, 95% CI 1.7–2.5) were associated with a greater likelihood of urethroplasty vs repeat endoscopic management. Conclusions Despite the well established benefits of urethroplasty compared to repeat endoscopic management a strong bias for repeat endoscopic management exists in many regions in the United States. PMID:25072180

  20. Endoscopic versus Open Bursectomy for Prepatellar and Olecranon Bursitis

    PubMed Central

    Meric, Gokhan; Sargin, Serdar; Atik, Aziz; Ulusal, Ali Engin

    2018-01-01

    Objectives Bursitis of the olecranon and the patella are not rare disorders, and conservative management is successful in most cases. However, when patients do not respond to conservative treatment, open excisional surgery or, recently, endoscopic bursectomy, can be used. The aim of this study was to evaluate the results of open and endoscopic treatments of olecranon and prepatellar bursitis. Patients and methods Forty-nine patients (37 male and 12 female), who were treated with endoscopic bursectomy (25 patients) or open bursectomy (24 patients) were included in this study. Thirty patients had olecranon bursitis, while 19 patients had prepatellar bursitis. The patients’ average age was 61.1 ± 12.3 (range 33-81) years. All of the patients’ hospitalization and surgery times were recorded. The satisfaction of the patients was evaluated with a satisfaction scoring system, as well as by evaluating residual pain, the range of joint movement, and the cosmetic results of the procedure. Results The average follow-up time was 16 ± 9 months (range 12–27). The median operation time was 23.2 ± 3.5 minutes for the endoscopic bursectomy group and 26.4 ± 6.8 minutes for the open bursectomy group. The median hospitalization time was 0.56 ± 0.5 days (range 0-1 day) for the endoscopic group and 1 ± 0 days for the open bursectomy group (P<0.01). According to the patient satisfaction questionnaire, the endoscopic bursectomy group’s score was 8.5 ± 1.3 (range 5-10), and the open bursectomy group’s score was 5.29 ± 1.8 (range 1-9) (P<0.01). Conclusion Endoscopic bursectomy is a time-saving and efficient surgical treatment option for patients with prepatellar and olecranon bursitis. PMID:29805943

  1. Endoscopic versus Open Bursectomy for Prepatellar and Olecranon Bursitis.

    PubMed

    Meric, Gokhan; Sargin, Serdar; Atik, Aziz; Budeyri, Aydin; Ulusal, Ali Engin

    2018-03-27

    Objectives Bursitis of the olecranon and the patella are not rare disorders, and conservative management is successful in most cases. However, when patients do not respond to conservative treatment, open excisional surgery or, recently, endoscopic bursectomy, can be used. The aim of this study was to evaluate the results of open and endoscopic treatments of olecranon and prepatellar bursitis. Patients and methods Forty-nine patients (37 male and 12 female), who were treated with endoscopic bursectomy (25 patients) or open bursectomy (24 patients) were included in this study. Thirty patients had olecranon bursitis, while 19 patients had prepatellar bursitis. The patients' average age was 61.1 ± 12.3 (range 33-81) years. All of the patients' hospitalization and surgery times were recorded. The satisfaction of the patients was evaluated with a satisfaction scoring system, as well as by evaluating residual pain, the range of joint movement, and the cosmetic results of the procedure. Results The average follow-up time was 16 ± 9 months (range 12-27). The median operation time was 23.2 ± 3.5 minutes for the endoscopic bursectomy group and 26.4 ± 6.8 minutes for the open bursectomy group. The median hospitalization time was 0.56 ± 0.5 days (range 0-1 day) for the endoscopic group and 1 ± 0 days for the open bursectomy group (P<0.01). According to the patient satisfaction questionnaire, the endoscopic bursectomy group's score was 8.5 ± 1.3 (range 5-10), and the open bursectomy group's score was 5.29 ± 1.8 (range 1-9) (P<0.01). Conclusion Endoscopic bursectomy is a time-saving and efficient surgical treatment option for patients with prepatellar and olecranon bursitis.

  2. A panoramic view of the skull base: systematic review of open and endoscopic endonasal approaches to four tumors

    PubMed Central

    Graffeo, Christopher S.; Dietrich, August R.; Grobelny, Bartosz; Zhang, Meng; Goldberg, Judith D.; Golfinos, John G.; Lebowitz, Richard; Kleinberg, David; Placantonakis, Dimitris G.

    2014-01-01

    Endoscopic endonasal surgery has been established as the safest approach to pituitary tumors, yet its role in other common skull base lesions has not been established. To answer this question, we carried out a systematic review of reported series of open and endoscopic endonasal approaches to four major skull base tumors: olfactory groove meningiomas (OGM), tuberculum sellae meningiomas (TSM), craniopharyngiomas (CRA), and clival chordomas (CHO). Data from 162 studies containing 5,701 patients were combined and compared for differences in perioperative mortality, gross total resection (GTR), cerebrospinal fluid (CSF) leak, neurological morbidity, post-operative visual function, post-operative anosmia, post-operative diabetes insipidus (DI), and post-operative obesity/hyperphagia. Weighted average rates for each outcome were calculated using relative study size. Our findings indicate similar rates of GTR and perioperative mortality between open and endoscopic approaches for all tumor types. CSF leak was increased after endoscopic surgery. Visual function symptoms were more likely to improve after endoscopic surgery for TSM, CRA, and CHO. Post-operative DI and obesity/hyperphagia were significantly increased after open resection in CRA. Recurrence rates per 1,000 patient-years of follow-up were higher in endoscopy for OGM, TSM, and CHO. Trends for open and endoscopic surgery suggested modest improvement in all outcomes over time. Our observations suggest that endonasal endoscopy is a safe alternative to craniotomy and may be preferred for certain tumor types. However, endoscopic surgery is associated with higher rates of CSF leak, and possibly increased recurrence rates. Prospective study with long-term follow-up is required to verify these preliminary observations. PMID:24014055

  3. Endoscopic Versus Microscopic Transsphenoidal Surgery in the Treatment of Pituitary Adenoma: A Systematic Review and Meta-Analysis.

    PubMed

    Li, Aijun; Liu, Weisheng; Cao, Peicheng; Zheng, Yuehua; Bu, Zhenfu; Zhou, Tao

    2017-05-01

    Inconsistent findings have been reported regarding the efficacy and safety of endoscopic and microscopic transsphenoidal surgery for pituitary adenoma. This study aimed to assess the benefits and shortcomings of these surgical methods in patients with pituitary adenoma. The electronic databases PubMed, Embase, and the Cochrane Library were systematically searched, as well as proceedings of major meetings. Eligible studies with a retrospective or prospective design that evaluated endoscopic versus microscopic methods in patients with pituitary adenoma were included. Primary outcomes included gross tumor removal, cerebrospinal fluid leak, diabetes insipidus, and other complications. Overall, 23 studies (4 prospective and 19 retrospective) assessing 2272 patients with pituitary adenoma were included in the final analysis. Endoscopic transsphenoidal surgery was associated with a higher incidence of gross tumor removal (odds ratio, 1.52; 95% confidence interval, 1.11-2.08; P = 0.009) than those with microscopic transsphenoidal surgery. In addition, endoscopic transsphenoidal surgery had no significant effect on the risk of cerebrospinal fluid leak, compared with microscopic transsphenoidal surgery. Furthermore, endoscopic transsphenoidal surgery was associated with a 22% reduction in risk of diabetes insipidus compared with microscopic transsphenoidal surgery, but the difference was not statistically significant. Endoscopic transsphenoidal surgery significantly reduced the risk of septal perforation (odds ratio, 0.29; 95% confidence interval, 0.11-0.78; P = 0.014) and was not associated with the risk of meningitis, epistaxis, hematoma, hypopituitarism, hypothyroidism, hypocortisolism, total mortality, and recurrence. Endoscopic transsphenoidal surgery is associated with higher gross tumor removal and lower incidence of septal perforation in patients with pituitary adenoma. Future large-scale prospective randomized controlled trials are needed to verify these findings. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Using external magnet guidance and endoscopically placed magnets to create suture-free gastro-enteral anastomoses.

    PubMed

    Myers, Christopher; Yellen, Benjamin; Evans, John; DeMaria, Eric; Pryor, Aurora

    2010-05-01

    To facilitate endolumenal and natural orifice procedures, this study evaluated a novel technique using external and endoscopically placed magnets to create suture-free gastroenteral anastomoses. Seven anesthetized adult swine underwent endoscopic placement of magnets into the small bowel and stomach. Using external magnets, the endoscopically placed internal magnets were brought into opposition under endoscopic view. After 1-2 weeks, the pigs were killed and analyzed. At laparotomy and under sterile conditions, peritoneal cultures were obtained. The anastomoses were evaluated endoscopically and tested using an air insufflation test. Finally, the anastomoses were resected and evaluated microscopically. The average operative time for endoscopic placement of the magnets was 34.3 +/- 14.8 min. Successful placement and creation of anastomoses occurred in six of the pigs. One pig did not form an anastomosis because the magnets were too large to pass through the pylorus at the time of attempted magnet placement. Six swine experienced uncomplicated postoperative courses. One pig's postoperative course involved constipation for several days, requiring additional fluids and fiber supplementation. The findings at endoscopy showed that the magnets were adhered to the anastomosis, which were easily freed, or within the stomach. The air insufflation test results were negative for all the pigs. At laparotomy, there was no evidence of infection, abscess, or leak, but two peritoneal culture results were positive with scant growth of Staphylococcus aureus and coagulase-negative staphylococcus, presumably contaminants. Microscopically, the anastomoses illustrated granulation and fibrous connective tissue without evidence of infection or leak. Endoscopically placed magnets with external magnet guidance is a feasible and novel approach to creating patent gastroenteral anastomoses without abdominal incisions or sutures.

  5. Contemporary management of frontal sinus mucoceles: a meta-analysis.

    PubMed

    Courson, Andy M; Stankiewicz, James A; Lal, Devyani

    2014-02-01

    To analyze trends in the surgical management of frontal and fronto-ethmoid mucoceles through meta-analysis. Meta-analysis and case series. A systematic literature review on surgical management of frontal and fronto-ethmoid mucoceles was conducted. Studies were divided into historical (1975-2001) and contemporary (2002-2012) groups. A meta-analysis of these studies was performed. The historical and contemporary cohorts were compared (surgical approach, recurrence, and complications). To study evolution in surgical management, a senior surgeon's experience over 28 years was analyzed separately. Thirty-one studies were included for meta-analysis. The historical cohort included 425 mucoceles from 11 studies. The contemporary cohort included 542 mucoceles from 20 studies. More endoscopic techniques were used in the contemporary versus historical cohort (53.9% vs. 24.7%; P = <0.001). In the authors' series, a higher percentage was treated endoscopically (82.8% of 122 mucoceles). Recurrence (P = 0.20) and major complication (P = 0.23) rates were similar between cohorts. Minor complication rates were superior for endoscopic techniques in both cohorts (P = 0.02 historical; P = <0.001 contemporary). In the historical cohort, higher recurrence was noted in the external group (P = 0.03). Results from endoscopic and open approaches are comparable. Although endoscopic techniques are being increasingly adopted, comparison with our series shows that more cases could potentially be treated endoscopically. Frequent use of open approaches may reflect efficacy, or perhaps lack of expertise and equipment required for endoscopic management. Most contemporary authors favor endoscopic management, limiting open approaches for specific indications (unfavorable anatomy, lateral disease, and scarring). N/A. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  6. New Berlin-Buch "reversed Nuss," endoscopic pectus carinatum repair using eight-hole stabilizers, submuscular CO2, and presternal Nuss bar compression: first results in 35 patients.

    PubMed

    Schaarschmidt, Klaus; Lempe-Sellin, Michael; Schlesinger, Frank; Jaeschke, Uwe; Polleichtner, Susanne

    2011-04-01

    Since 2001 we minimized access (2.9-4.7 cm) for universally applicable endoscopic hybrid carinatum technique with two transsternal Willital bars in 173 endoscopic hybrid (EH) patients with very satisfactory results. In 2008-2009, endoscopic Nuss bar compression with endoscopic repair of costal flaring applied a new eight-hole stabilizer, which allows the use in pectus carinatum (PC) beyond adolescence including redos and combined deformities. This prospective study of 35 "endoscopic Berlin-Buch reversed Nuss" repairs intends to establish indications for this improved technique. In February 2008 to February 2010, we used endoscopic Nuss bar compression by applying a bilateral new eight-hole stabilizer fixed to the bar without screws or wires, which allows unprecedented versatility and the use in pectus carinatum beyond adolescence. Thirty-five patients aged 17.05 ± 10.2 years (range: 11.3-33.1 years) were recorded prospectively and followed at 3 monthly intervals. We implanted a standard Nuss bar (11-14') into an endoscopically dissected submuscular presternal pocket correcting PC by sternal pressure. The bars were put under tension by traction via bilateral eight-hole stabilizers and three pericostal wire sutures on each side. Bars were removed after 2 years. All 35 "reversed Nuss" pectus carinatum repairs, including 2 redos after Ravitch, were successful, with no conversion. So far there was no local or general complication and no seroma or bar dislocation. Thirty-one patients judged their result as excellent and 4 as good. Although this is a very early experience, "reversed Nuss" is safe and effective and new technical improvements have expanded the range of applicability to older patients and suitable redos.

  7. Peroral Endoscopic Myotomy Versus Heller Myotomy for Achalasia: Pros and Cons.

    PubMed

    Tefas, Cristian; Ababneh, Rami; Tanţău, Marcel

    2018-01-01

    Achalasia is an esophageal motor disorder that has multiple endoscopic and surgical methods of treatment. However, there is no consensus on optimal therapy in patients suffering from this disorder. This review discusses two therapies with similar but technically different concepts, peroral endoscopic myotomy and Heller surgical myotomy. After a brief introduction to the basic problems of achalasia, technical considerations, intra and postprocedural complications are presented and the advantages and disadvantages of the two procedures are discussed, based on the relevant articles in the literature. Heller surgical myotomy and peroral endoscopic myotomy appear to be similar in performance with similar results in terms of gastroesophageal reflux rates. However, with experience being gained in the field of endoscopic myotomy, this procedure seems more advantageous, with similar success rates to those of the established surgical technique, but offering shorter operating times, shorter hospitalizations and, ultimately, lower costs. Celsius.

  8. Combined use of clips and nylon snare ("tulip-bundle") as a rescue endoscopic bleeding control in a mallory-weiss syndrome.

    PubMed

    Ivekovic, Hrvoje; Radulovic, Bojana; Jankovic, Suzana; Markos, Pave; Rustemovic, Nadan

    2014-01-01

    Mallory-Weiss syndrome (MWS) accounts for 6-14% of all cases of upper gastrointestinal bleeding. Prognosis of patients with MWS is generally good, with a benign course and rare recurrence of bleeding. However, no strict recommendations exist in regard to the mode of action after a failure of primary endoscopic hemostasis. We report a case of an 83-year-old male with MWS and rebleeding after the initial endoscopic treatment with epinephrine and clips. The final endoscopic control of bleeding was achieved by a combined application of clips and a nylon snare in a "tulip-bundle" fashion. The patient had an uneventful postprocedural clinical course and was discharged from the hospital five days later. To the best of our knowledge, this is the first case report showing the "tulip-bundle" technique as a rescue endoscopic bleeding control in the esophagus.

  9. [Delayed endoscopic reconstruction of the anterior wall of the frontal sinus: Technical note].

    PubMed

    Mommers, X-A; Zwetyenga, N; Meningaud, J-P

    2015-11-01

    Reconstruction of the anterior wall of the frontal sinus usually requires a coronal incision. This extended approach may lead to paresthesia, unsightly scars, bruises and cicatricial alopecia. These complications encouraged several authors to endoscopic management of this kind of fractures. We present a delayed technique of reconstruction of the anterior wall of the frontal sinus by means of endoscopic hydroxyapatite filling. Two incisions were performed behind the hair line. Subperiosteal dissection using a periosteal elevator was performed. A 30° angled endoscope was used to visualize the depression. The latter was filled by Hydroset® (Stryker, USA) as a bone substitute. In the absence of contra-indication, the reconstruction of the anterior wall of the frontal sinus by means of endoscopic hydroxyapatite filling has many advantages including uneventful outcome, reduction of the hospital stay and a fast learning curve. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Endoscopic ultrasonography guided drainage: Summary of consortium meeting, May 21, 2012, San Diego, California

    PubMed Central

    Kahaleh, Michel; Artifon, Everson LA; Perez-Miranda, Manuel; Gaidhane, Monica; Rondon, Carlos; Itoi, Takao; Giovannini, Marc

    2015-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is the preferred procedure for biliary and pancreatic drainage. While ERCP is successful in about 95% of cases, a small subset of cases are unsuccessful due to altered anatomy, peri-ampullary pathology, or malignant obstruction. Endoscopic ultrasound-guided drainage is a promising technique for biliary, pancreatic and recently gallbladder decompression, which provides multiple advantages over percutaneous or surgical biliary drainage. Multiple retrospective and some prospective studies have shown endoscopic ultrasound-guided drainage to be safe and effective. Based on the currently reported literature, regardless of the approach, the cumulative success rate is 84%-93% with an overall complication rate of 16%-35%. endoscopic ultrasound-guided drainage seems a viable therapeutic modality for failed conventional drainage when performed by highly skilled advanced endoscopists at tertiary centers with expertise in both echo-endoscopy and therapeutic endoscopy PMID:25624708

  11. Cutting‐edge endonasal surgical approaches to thyroid ophthalmopathy

    PubMed Central

    Tyler, Matthew A.; Zhang, Caroline C.; Saini, Alok T.

    2018-01-01

    Objective Thyroid orbitopathy is a poorly understood extrathyroidal manifestation of Graves' disease that can cause disfiguring proptosis and vision loss. Orbital decompression surgery for Graves' orbitopathy (GO) can address both cosmetic and visual sequelae of this autoimmune condition. Endonasal endoscopic orbital decompression provides unmatched visualization and access to inferomedial orbital wall and orbital apex. This review examines the state of the art approaches employed in endonasal endoscopic orbital decompression for GO. Methods Review of literature evaluating novel surgical maneuvers for GO. Results Studies examining the efficacy of endonasal endoscopic orbital decompression are heterogenous and retrospective in design; however, they reveal this approach to be a safe and effective technique in the management of GO. Conclusion Subtle variations in endoscopic techniques significantly affect postsurgical outcomes and can be tailored to the specific clinical indication in GO making endonasal endoscopic decompression the most versatile approach available. Level of Evidence NA. PMID:29721541

  12. 4-mm-diameter three-dimensional imaging endoscope with steerable camera for minimally invasive surgery (3-D-MARVEL).

    PubMed

    Bae, Sam Y; Korniski, Ronald J; Shearn, Michael; Manohara, Harish M; Shahinian, Hrayr

    2017-01-01

    High-resolution three-dimensional (3-D) imaging (stereo imaging) by endoscopes in minimally invasive surgery, especially in space-constrained applications such as brain surgery, is one of the most desired capabilities. Such capability exists at larger than 4-mm overall diameters. We report the development of a stereo imaging endoscope of 4-mm maximum diameter, called Multiangle, Rear-Viewing Endoscopic Tool (MARVEL) that uses a single-lens system with complementary multibandpass filter (CMBF) technology to achieve 3-D imaging. In addition, the system is endowed with the capability to pan from side-to-side over an angle of [Formula: see text], which is another unique aspect of MARVEL for such a class of endoscopes. The design and construction of a single-lens, CMBF aperture camera with integrated illumination to generate 3-D images, and the actuation mechanism built into it is summarized.

  13. Submucosal tunneling techniques: current perspectives.

    PubMed

    Kobara, Hideki; Mori, Hirohito; Rafiq, Kazi; Fujihara, Shintaro; Nishiyama, Noriko; Ayaki, Maki; Yachida, Tatsuo; Matsunaga, Tae; Tani, Johji; Miyoshi, Hisaaki; Yoneyama, Hirohito; Morishita, Asahiro; Oryu, Makoto; Iwama, Hisakazu; Masaki, Tsutomu

    2014-01-01

    Advances in endoscopic submucosal dissection include a submucosal tunneling technique, involving the introduction of tunnels into the submucosa. These tunnels permit safer offset entry into the peritoneal cavity for natural orifice transluminal endoscopic surgery. Technical advantages include the visual identification of the layers of the gut, blood vessels, and subepithelial tumors. The creation of a mucosal flap that minimizes air and fluid leakage into the extraluminal cavity can enhance the safety and efficacy of surgery. This submucosal tunneling technique was adapted for esophageal myotomy, culminating in its application to patients with achalasia. This method, known as per oral endoscopic myotomy, has opened up the new discipline of submucosal endoscopic surgery. Other clinical applications of the submucosal tunneling technique include its use in the removal of gastrointestinal subepithelial tumors and endomicroscopy for the diagnosis of functional and motility disorders. This review suggests that the submucosal tunneling technique, involving a mucosal safety flap, can have potential values for future endoscopic developments.

  14. Modified endoscopic medial maxillectomy for zygomatic implant salvage.

    PubMed

    Schwartz, Joseph S; Tajudeen, Bobby A; Adappa, Nithin D; Palmer, James N

    2016-01-01

    Odontogenic chronic rhinosinusitis (CRS) is an epidemiologically important disease process due, in part, to the increasingly commonplace use of dental restorative procedures such as zygomatic implantation. Traditional management of this clinical entity typically entails extraction of the infected hardware via an open or endoscopic approach. We describe a novel management strategy of odontogenic CRS following bilateral zygomatic implantation for oral rehabilitation that we surgically salvaged via a modified endoscopic medial maxillectomy. We describe the presentation and management of a case of metachronous development of bilateral CRS subsequent to zygomatic implantation. The patient's postoperative course was characterized by marked endoscopic, radiologic, and symptomatic improvement as measured by the 22-item Sino-Nasal Outcome Test. We describe a novel treatment strategy for the management of odontogenic sinusitis resulting from erroneous zygomatic implant placement. Modified endoscopic medial maxillectomy in this clinical context facilitates mucosal normalization of the affected sinus, while permitting preservation of oral function through salvage of the displaced implant.

  15. Endoscopic Management of Peri-Pancreatic Fluid Collections.

    PubMed

    Yip, Hon Chi; Teoh, Anthony Yuen Bun

    2017-09-15

    In the past decade, there has been a progressive paradigm shift in the management of peri-pancreatic fluid collections after acute pancreatitis. Refinements in the definitions of fluid collections from the updated Atlanta classification have enabled better communication amongst physicians in an effort to formulate optimal treatments. Endoscopic ultrasound (EUS)-guided drainage of pancreatic pseudocysts has emerged as the procedure of choice over surgical cystogastrostomy. The approach provides similar success rates with low complications and better quality of life compared with surgery. However, an endoscopic "step up" approach in the management of pancreatic walled-off necrosis has also been advocated. Both endoscopic and percutaneous drainage routes may be used depending on the anatomical location of the collections. New-generation large diameter EUS-specific stent systems have also recently been described. The device allows precise and effective drainage of the collections and permits endoscopic necrosectomy through the stents.

  16. Implementation of remote video auditing with feedback and compliance for manual-cleaning protocols of endoscopic retrograde cholangiopancreatography endoscopes.

    PubMed

    Armellino, Donna; Cifu, Kelly; Wallace, Maureen; Johnson, Sherly; DiCapua, John; Dowling, Oonagh; Jacobs, Mitchel; Browning, Susan

    2018-05-01

    A pilot initiative to assess the use of remote video auditing in monitoring compliance with manual-cleaning protocols for endoscopic retrograde cholangiopancreatography (ERCP) endoscopes was performed. Compliance with manual-cleaning steps following the initiation of feedback was measured. A video feed of the ERCP reprocessing room was provided to remote auditors who scored items of an ERCP endoscope manual-cleaning checklist. Compliance feedback was provided in the form of reports and reeducation. Outcomes were reported as checklist compliance. The use of remote video auditing to document manual processing is a feasible approach and feedback and reeducation increased manual-cleaning compliance from 53.1% (95% confidence interval, 34.7-71.6) to 98.9% (95.0% confidence interval, 98.1-99.6). Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. Unconvincing diagnosis of a rare subtype of primary gastric lymphoma with incongruent endoscopic presentation: a case of gastric schwannoma.

    PubMed

    Lee, Seung Soo; Kim, In Ho

    2013-12-01

    Primary gastric lymphoma is a rare gastric malignancy. Its diagnostic process is complex. Clinician may find initial diagnosis of primary gastric lymphoma unreliable, especially when it indicates the rarest subtype of gastric lymphoma, while its initial endoscopic presentation fails to raise the slightest suspicion of primary gastric lymphoma. A 53-year-old Korean man was diagnosed, by endoscopic examination, with a round submucosal tumor of the stomach. Deep endoscopic biopsy, however, confirmed CD5 positive gastric lymphoma. Surgical treatment was performed for diagnosis and treatment. Postoperative histo-logical examination confirmed gastric schwannoma. Gastric schwannoma is a spindle cell tumor, characterized by a peripheral cuff-like lymphocytic infiltration. Deep endoscopic biopsy may have been misdirected to the peripheral lymphoid cuff, failing to acquire spindle cells. The literature has been reviewed, and options for diagnostic accuracy have been suggested.

  18. Analysis of a concentric-tube robot design and feasibility for endoscopic deployment

    NASA Astrophysics Data System (ADS)

    Ponten, Ryan; Black, Caroline B.; Russ, Andrew J.; Rucker, D. Caleb

    2017-03-01

    An intraluminal endoscopic approach is desirable for most colonoscopic procedures and is growing in favor for other surgeries as tools are enhanced. Flexible robotic manipulators could further enhance the dexterity and precision of commercial endoscopic systems. In this paper, we explore the capabilities of concentric tube robots to work as tool manipulators at the tip of a colonoscope to perform endoscopic submucousal dissection (ESD) and endoscopic full thickness resection (EFTR). We provide an overview of the kinematic modeling of these manipulators, a design of a prototype manipulator and the transmission actuation system. Our analysis examines the workspace and stiffness of these manipulators being controlled at the tip of a colonoscope. We compare the results to reported surgical requirements and propose solutions for enhancing their effectiveness including notching tubes with a larger Young's Modulus. We also determine the resolution and accuracy of the actuation system.

  19. Endoscopic Modified Medial Maxillectomy for Fungal Ball of the Hypoplastic Maxillary Sinus With Bony Hypertrophy.

    PubMed

    Nomura, Kazuhiro; Ikushima, Hiroyuki; Ozawa, Daiki; Shimizu, Yuichi; Arakawa, Kazuya; Suzuki, Jun; Hidaka, Hiroshi; Katori, Yukio; Ohyama, Kenji

    2018-05-01

    Sinus fungal ball is defined as noninvasive chronic rhino-sinusitis with a clump of mold in the paranasal sinuses, typically affecting the maxillary sinus. Fairly good outcomes of endoscopic surgery have been reported where the ball is removed through the antrostomy. However, the affected sinus tends to have a smaller cavity and thicker bony walls. As such, it is often challenging to maintain a window size that is sufficient to control possible recurrence. The endoscopic modified medial maxillectomy procedure was applied to a 61-year old and a 70-year old female patient with maxillary sinus fungal ball. Using this method, we created a much larger inferior meatal antrostomy without difficulty. The window provided us with an endoscopic view of the whole sinus and complete eradication of the lesion. Endoscopic modified medial maxillectomy is useful as a surgical procedure for maxillary sinus fungal ball and should be considered for better outcomes.

  20. The Effectiveness of Endoscopic Gastroplasty for Obesity Treatment According to FDA Thresholds: Systematic Review and Meta-Analysis Based on Randomized Controlled Trials.

    PubMed

    Madruga-Neto, Antonio Coutinho; Bernardo, Wanderley Marques; de Moura, Diogo Turiani Hourneaux; Brunaldi, Vitor Ottoboni; Martins, Rafael Krieger; Josino, Iatagan Rocha; de Moura, Eduardo Turiani Hourneaux; de Souza, Thiago Ferreira; Santo, Marco Aurélio; de Moura, Eduardo Guimarães Hourneaux

    2018-06-16

    Endoscopic bariatric therapies (EBTs) are promising alternatives to conventional surgery for obesity. The aim of this study is to compare efficacy and safety through a systematic review and meta-analysis of the endoscopic gastroplasty techniques versus conservative treatment. We searched MEDLINE, EMBASE, Cochrane CENTRAL, Lilacs/Bireme. Randomized controlled trials (RCTs) enrolling obese patients comparing endoscopic gastroplasty to sham or diet/exercise were considered eligible. Among 6014 records, three RCTs were selected for meta-analysis. The total sample was 459 patients (312 EBTs vs 147 control). Mean total body weight loss in the intervention group (IG) was 4.8% higher than the control group (CG) at 12 months (p = 0.01). The IG responder rate was 44.31% at 12 months. Therefore, the endoscopic gastroplasty is more effective than conservative therapies but do not achieve FDA thresholds.

  1. Endoscopic ampullectomy: a practical guide

    PubMed Central

    Bassan, Milan

    2012-01-01

    Endoscopic ampullectomy is a minimally invasive method of treating superficial lesions of the ampulla of Vater. With careful patient selection and lesion assessment it is a safe and efficacious therapeutic procedure that can obviate the need for potentially major surgical intervention. Strategies for safe and successful endoscopic ampullectomy with a focus on resection technique and recognition and management of complications are presented. PMID:22586547

  2. Endoscopic Therapies for Chronic Pancreatitis.

    PubMed

    Adler, Jeffrey M; Gardner, Timothy B

    2017-07-01

    Chronic pancreatitis is a fibroinflammatory disease of the pancreas leading to varying degrees of endocrine and exocrine dysfunction. Treatment options are generally designed to control the pain of chronic pancreatitis, and endoscopic therapy is one of the main treatment modalities. Herein, we describe the endoscopic management of pancreatic duct calculi and strictures, entrapment of the intrapancreatic bile duct, celiac plexus interventions, and drainage of pancreatic pseudocysts.

  3. [Calculation of optic system of superfine medical endoscopes based on gradient elements].

    PubMed

    Díakonov, S Iu; Korolev, A V

    1994-01-01

    The application of gradient optic elements to rigid endoscopes decreases their diameter to 1.5-2.0 mm. The given mathematical dependences determine aperture and field characteristics, focus and focal segments, resolution of the optic systems based on gradient optics. Parameters of the gradient optic systems for superfine medical endoscopes are characterized and their practical application is shown.

  4. Eltrombopag Use in Thrombocytopenia for Endoscopic Submucosal Dissection of a Gastric Carcinoid

    PubMed Central

    Kaltenbach, Tonya; Martin, Beth; Rouse, Robert V.; Soetikno, Roy

    2014-01-01

    Severe thrombocytopenia is a contraindication for therapeutic endoscopy due to the risk of bleeding. Platelet transfusions can temporarily increase platelet count, but are difficult to administer in the 2 weeks following endoscopic resection, during which the patient is at high risk for delayed bleeding. We present the use of a novel thrombopoietin receptor agonist, eltrombopag, to sustain platelet levels for the safe and complete endoscopic submucosal dissection of a gastric carcinoid in a patient with severe thrombocytopenia due to cirrhosis and idiopathic thrombocytopenic purpura. We performed complete and safe endoscopic removal of a gastric carcinoid after correcting the thrombocytopenia. PMID:26157896

  5. Performance evaluation of stereo endoscopic imaging system incorporating TFT-LCD.

    PubMed

    Song, C-G; Park, S-K

    2005-01-01

    This paper presents a 3D endoscopic video system designed to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. In a comparison of the polarized and electric shutter-type stereo imaging systems, the former was found to be superior in terms of both accuracy and speed for knot-tying and for the loop pass test. The results of our experiments show that the proposed 3D endoscopic system has a sufficiently wide viewing angle and zone for multi-viewing, and that it provides better image quality and more stable optical performance compared with the electric shutter-type.

  6. High Resolution Sub-MM Fiberoptic Endoscope Final Report CRADA No. TSB-1447-97

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stone, Gary F.; Smith, John

    2018-01-22

    At the time of the CRADA, LLNL needed to develop a sub-mm outer diameter fiberoptic endoscope with 25pm or better resolution at 3-lOmm working distance to support the Enhanced Surveillance Program (ESP) and the Core Surveillance Program for DOE. The commercially available systems did not meet the image resolution requirements and development work was needed to reach three goals. We also needed to perform preliminary investigations into the production of such an endoscope with a steerable-articulated distal end. The goal of such an endoscope was to allow for a 45 degree inspection cone including the lens field of view.

  7. Accidental hijab pin ingestion in Muslim women: an emerging endoscopic emergency?

    PubMed Central

    Goh, Jason; Patel, Neeral; Boulton, Ralph

    2014-01-01

    Ingested foreign body is an infrequent indication for emergency endoscopy in the adult gastroenterology practice. We describe the clinical features and endoscopic management of the first four cases of accidental ingestion of hijab pins by Muslim women in our unit, all presenting within a 12-month period. The pins were all successfully retrieved without any complications. In this report, we review published guidelines and the current literature, as well as discussing the approach (conservative vs proactive endoscopic retrieval) and timing of endoscopic treatment. The Muslim community may need to be alerted to the potential health hazard of hijab pins. PMID:24390968

  8. Retrospective study of Candida sp. contaminations of endoscopes at the University Hospital of Tlemcen (Algeria).

    PubMed

    Hassaine-Lahfa, I; Boucherit-Otmani, Z; Sari-Belkherroubi, L; Boucherit, K

    2017-06-01

    Improper cleaning and disinfection of endoscopes has been responsible for multiple nosocomial outbreaks and sometimes serious life-threatening infections. The aim of our study is, at first, to identify Candida species responsible for the contamination of endoscopes, and to determine the minimal inhibitory concentrations of planktonic (MIC) and sessile cells (SMIC) of amphotericin B (AmB) against our isolated strains. The present study was performed on four endoscopes in the department of gastroenterology at the University Hospital of Tlemcen (Algeria). A total of 300 samples from endoscopes were examined over a period of 3years. Thirty-four strains of Candida sp. were isolated, representing 11.33% of the considered samples. The number of isolated strains dropped significantly in the second and the third year compared to the first year of our study. After testing the antifungal property of amphotericin B, we showed clearly that the sessile cells of Candida sp. were much more resistant than their planktonic counterparts (suspended cells). The methods of sterilization of the endoscopes are very important; drying by compressed air is a critical step that reduces significantly the number of yeasts contamination. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. 3D imaging with a single-aperture 3-mm objective lens: concept, fabrication, and test

    NASA Astrophysics Data System (ADS)

    Korniski, Ronald; Bae, Sam Y.; Shearn, Michael; Manohara, Harish; Shahinian, Hrayr

    2011-10-01

    There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the- shelf (COTS) components including the ones used in the endoscope objective.

  10. How to Improve the Quality of Screening Endoscopy in Korea: National Endoscopy Quality Improvement Program.

    PubMed

    Cho, Yu Kyung

    2016-07-01

    In Korea, gastric cancer screening, either esophagogastroduodenoscopy or upper gastrointestinal series (UGIS), is performed biennially for adults aged 40 years or older. Screening endoscopy has been shown to be associated with localized cancer detection and better than UGIS. However, the diagnostic sensitivity of detecting cancer is not satisfactory. The National Endoscopy Quality Improvement (QI) program was initiated in 2009 to enhance the quality of medical institutions and improve the effectiveness of the National Cancer Screening Program (NCSP). The Korean Society of Gastrointestinal Endoscopy developed quality standards through a broad systematic review of other endoscopic quality guidelines and discussions with experts. The standards comprise five domains: qualifications of endoscopists, endoscopic unit facilities and equipment, endoscopic procedure, endoscopy outcomes, and endoscopic reprocessing. After 5 years of the QI program, feedback surveys showed that the perception of QI and endoscopic practice improved substantially in all domains of quality, but the quality standards need to be revised. How to avoid missing cancer in endoscopic procedures in daily practice was reviewed, which can be applied to the mass screening endoscopy. To improve the quality and effectiveness of NCSP, key performance indicators, acceptable quality standards, regular audit, and appropriate reimbursement are necessary.

  11. “Puestow modified procedure in the era of advanced endoscopic interventions for the management of chronic lithiasic pancreatitis. A two cases report”

    PubMed Central

    Fragulidis, Georgios P.; Vezakis, Αntonios; Dellaportas, Dionissios; Sotirova, Ira; Koutoulidis, Vassilis; Kontis, Elliseos; Polydorou, Andreas

    2015-01-01

    Introduction Pancreatic duct calculi in chronic pancreatitis (CP) patients are the main cause of intractable pain which is their main symptom. Decompression options of for the main pancreatic duct are both surgical and advanced endoscopic procedures. Presentation of cases A 64-year-old male with known CP due to alcohol consumption and a 36-year-old female with known idiopathic CP and pancreatic duct calculi were managed recently in our hospital where endoscopic procedures were unsuccessful. A surgical therapy was considered and a longitudinal pancreaticojejunostomy (modified Puestow procedure) in both patients was performed with excellent results. Discussion Over the last 30 years, endoscopic procedures are developed to manage pancreatic duct strictures and calculi of the main pancreatic duct in CP patients. In both of our cases endoscopic therapy was first attempted but failed to extract the pancreatic duct stones, due to their size and speculations. Modified Puestow procedure was performed for both and it was successful for long term pain relief. Conclusion Despite advancement in endoscopic interventions and less invasive therapies for the management of chronic lithiasic pancreatitis we consider that classic surgical management can be appropriate in certain cases. PMID:26318135

  12. Early experience with endoscopic lumbar sympathectomy for plantar hyperhidrosis.

    PubMed

    Singh, Sanjay; Kaur, Simranjit; Wilson, Paul

    2016-05-01

    We describe our endoscopic lumbar sympathectomy technique and our early experience using it to treat plantar hyperhidrosis. We reviewed 20 lumbar sympathectomies performed in our vascular unit for plantar hyperhidrosis in 10 patients from 2011 and 2014. Demographics and outcomes were analyzed and a review of the literature conducted. All procedures were carried out endoscopically with no intraoperative or postoperative morbidity. Plantar anhidrosis was achieved in all the patients, although two patients (20%) suffered a relapse. Unwanted side-effects occurred in the form of compensatory sweating in three patients (30%) and post-sympathectomy neuralgia in two patients (20%). None of the patients experienced sexual dysfunction. Management of plantar hyperhidrosis may be based upon a therapeutic ladder starting with conservative measures and working up to surgery depending on the severity of the disease. Minimally invasive (endoscopic) sympathectomy for the thoracic chain is well established, but minimally invasive sympathectomy for the lumbar chain is a relatively new technique. Endoscopic lumbar sympathectomy provides an effective, minimally invasive method of surgical management, but long-term data are lacking. © 2016 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  13. One-step endosonography-guided drainage of a pancreatic pseudocyst: a new technique of stent delivery through the echo endoscope.

    PubMed

    Vilmann, P; Hancke, S; Pless, T; Schell-Hincke, J D; Henriksen, F W

    1998-10-01

    We report here the first case of a one-step endosonography(EUS)-guided pseudocyst drainage. A prototype large channel curved array echo endoscope (Pentax FG-38 UX) and a prototype delivery system for placement of an endoprosthesis was used for the procedure. The delivery system (GIP MedicinTechnik GmbH/Medi-Globe Corporation) consists of a handle part with a piston, a metal ring sheath, a plastic catheter with a diathermy needle and a double pigtail endoprosthesis (8.5 Fr). When mounted on the endoscope the endoprosthesis can be advanced out of the distal end of the endoscope. The introduction of the stent as well as the stent release can be monitored entirely by ultrasound. The procedure was tested in a 76-year-old woman with a pseudocyst measuring 60 mm in diameter located in the tail of the pancreas. The procedure was well tolerated by the patient, and there were no procedural complications. The advantage of a large channel echo endoscope and our new prototype delivery system is that the endoprosthesis can be inserted in to a pancreatic cyst guided exclusively by EUS without exchange of endoscopes, catheters or guide wires. Further studies are warranted.

  14. Sinonasal outcomes following endoscopic anterior skull base surgery with nasoseptal flap reconstruction: a prospective study.

    PubMed

    Hanson, M; Patel, P M; Betz, C; Olson, S; Panizza, B; Wallwork, B

    2015-07-01

    To assess nasal morbidity resulting from nasoseptal flap use in the repair of skull base defects in endoscopic anterior skull base surgery. Thirty-six patients awaiting endoscopic anterior skull base surgery were prospectively recruited. A nasoseptal flap was used for reconstruction in all cases. Patients were assessed pre-operatively and 90 days post-operatively via the Sino-Nasal Outcome Test 20 questionnaire and visual analogue scales for nasal obstruction, pain, secretions and smell; endoscopic examination findings and mucociliary clearance times were also recorded. Sino-Nasal Outcome Test 20 questionnaire data and visual analogue scale scores for pain, smell and secretions showed no significant differences between pre- and post-operative outcomes, with visual analogue scale scores for nasal obstruction actually showing a significant improvement (p = 0.0007). A significant deterioration for both flap and non-flap sides was demonstrated post-operatively on endoscopic examination (p = 0.002 and p = 0.02 respectively). Whilst elevation of a nasoseptal flap in endoscopic surgery of the anterior skull base engendered significant clinical deterioration on examination post-operatively, quality of life outcomes showed that no such deterioration was subjectively experienced by the patient. In fact, there was significant nasal airway improvement following nasoseptal flap reconstruction.

  15. A High-Resolution Endoscope of Small Diameter Using Electromagnetically Vibration of Single Fiber

    NASA Astrophysics Data System (ADS)

    Matsunaga, Tadao; Hino, Ryunosuke; Makishi, Wataru; Esashi, Masayoshi; Haga, Yoichi

    For high resolution visual inspection in the narrow space of the human body, small diameter endoscope has been developed which utilize electromagnetically vibration of single fiber. Thin endoscopes are effective for inspection in the narrow space of the human body, for example, in the blood vessel, lactiferous duct for detection infiltration of breast cancer, and periodontal gap between gingiva and tooth. This endoscope consists of single optical fiber and photofabricated driving coils. A collimator lens and a cylindrical permanent magnet are fixed on the optical fiber, and the tilted driving coils have been patterned on a 1.08 mm outer diameter thin tube. The fiber is positioned at the center of the tube which is patterned the coils. When an electrical alternating current at the resonance frequency is supplied to the coils, the permanent magnet which is fixed to the fiber is vibrated electromagnetically and scanned one or two dimensionally. This paper reports small diameter endoscope by using electromagnetically vibration of single fiber. Optical coherence tomography imaging has also been carried out with the fabricated endoscope and cross-section image of sub-surface skin of thumb was observed.

  16. Does Lymphocytic Colitis Always Present with Normal Endoscopic Findings?

    PubMed Central

    Park, Hye Sun; Han, Dong Soo; Ro, Youngouk; Eun, Chang Soo; Yoo, Kyo-Sang

    2015-01-01

    Background/Aims Although normal endoscopic findings are, as a rule, part of the diagnosis of microscopic colitis, several cases of macroscopic lesions (MLs) have been reported in collagenous colitis, but hardly in lymphocytic colitis (LC). The aim of this study was to investigate the endoscopic, clinical, and histopathologic features of LC with MLs. Methods A total of 14 patients with LC who were diagnosed between 2005 and 2010 were enrolled in the study. Endoscopic, clinical, and histopathologic findings were compared retrospectively according to the presence or absence of MLs. Results MLs were observed in seven of the 14 LC cases. Six of the MLs exhibited hypervascularity, three exhibited exudative bleeding and one exhibited edema. The patients with MLs had more severe diarrhea and were taking aspirin or proton pump inhibitors. More intraepithelial lymphocytes were observed during histologic examination in the patients with MLs compared to the patients without MLs, although this difference was not significant. The numbers of mononuclear cells and neutrophils in the lamina propria were independent of the presence or absence of MLs. Conclusions LC does not always present with normal endoscopic findings. Hypervascularity and exudative bleeding are frequent endoscopic findings in patients with MLs. PMID:25167800

  17. Endoscopic management of bile leakage after liver transplantation.

    PubMed

    Oh, Dong-Wook; Lee, Sung Koo; Song, Tae Jun; Park, Do Hyun; Lee, Sang Soo; Seo, Dong-Wan; Kim, Myung-Hwan

    2015-05-23

    Endoscopic retrograde cholangiopancreatography (ERCP) can be an effective treatment for bile leakage after liver transplantation. We evaluated the efficacy of endoscopic treatment in liver transplantation in patients who developed bile leaks. Forty-two patients who developed bile leaks after liver transplantation were included in the study. If a bile leak was observed on ERCP, a sphincterotomy was performed, and a nasobiliary catheter was then inserted. If a bile leak was accompanied by a bile duct stricture, either the stricture was dilated with balloons, followed by nasobiliary catheter insertion across the bile duct stricture, or endoscopic retrograde biliary drainage was performed. In the bile leakage alone group (22 patients), endoscopic treatment was technically successful in 19 (86.4%) and clinically successful in 17 (77.3%) cases. Among the 20 patients with bile leaks with bile duct strictures, endoscopic treatment was technically successful in 13 (65.0%) and clinically successful in 10 (50.0%) cases. Among the 42 patients who underwent ERCP, technical success was achieved in 32 (76.2%) cases and clinical success was achieved in 27 (64.3%) cases. ERCP is an effective and safe therapeutic modality for bile leaks after liver transplantation. ERCP should be considered as an initial therapeutic modality in post-liver transplantation patients.

  18. Transanal endoscopic microsurgery: a New Zealand experience.

    PubMed

    Bloomfield, Ian; Van Dalen, Roelof; Lolohea, Simione; Wu, Linus

    2018-06-01

    Transanal endoscopic microsurgery (TEMS) is a proven alternative therapy to either radical surgery or endoscopic mucosal resection for rectal neoplasms. It has proven benefits with lower morbidity and mortality compared with total mesorectal excision, and a lower local recurrence rate when compared to endoscopic mucosal techniques. A retrospective data collection of TEMS procedures performed through Waikato District Health Board, New Zealand, from 2010 to 2015 was conducted. Supportive follow-up data were sourced from patient records and from local centres around New Zealand. A total of 137 procedures were performed over the study period, with five being repeat procedures. Procedures were mostly performed for benign lesions (66.4%) with an overall complication rate of 15.3%, only five of which were Clavien-Dindo grade III (3.6%). Our local recurrence rate after resection of benign lesions was 5.1%. Our data set demonstrates the TEMS procedure to be safe compared to radical resection (total mesorectal excision) for sessile rectal lesions. Close endoscopic follow-up is recommended, especially for close or incomplete margins. Good therapeutic results can be obtained for appropriately selected early malignant lesions. TEMS provides better oncological results than endoscopic mucosal resection or transanal excision. © 2017 Royal Australasian College of Surgeons.

  19. An Automated Self-Learning Quantification System to Identify Visible Areas in Capsule Endoscopy Images.

    PubMed

    Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao

    2017-08-01

    Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.

  20. Endoscopic thyroidectomy with the da Vinci robot system using the bilateral axillary breast approach (BABA) technique: our initial experience.

    PubMed

    Lee, Kyu Eun; Rao, Jaideepraj; Youn, Yeo-Kyu

    2009-06-01

    Robotic surgery is useful in areas with difficult access like the pelvis. The ideal indications for robotic surgery are still to be established. The neck area, especially the thyroid gland poses a difficult challenge for many endoscopic surgeons. Robotic surgery is useful in this area due to its excellent magnification and endowrist function. We present our initial experience with robotic endoscopic thyroidectomy using the bilateral axillary breast approach (BABA). Between March and May 2008, 15 patients diagnosed with papillary thyroid cancer underwent robotic-assisted endoscopic thyroidectomy using the BABA technique. The mean operating time was 218 minutes. There was a steady decrease in operative time from the initial case to the 15th case. The blood loss was minimal. The recurrent laryngeal nerve and parathyroid glands were identified in great detail with ease and preserved in all cases. There were no postoperative complications in any case. Robotic endoscopic thyroidectomy using the BABA technique is a feasible procedure and can be performed safely. It provides an excellent operative field view enabling easy identification of vital structures. It also gives the desired cosmetic results and minimal postoperative pain similar to conventional endoscopic thyroid surgery using the BABA technique.

  1. Histologic characteristics of gastric polyps in Korea: Emphasis on discrepancy between endoscopic forceps biopsy and endoscopic mucosal resection specimen

    PubMed Central

    Yoon, Won Jae; Lee, Dong Ho; Jung, Yong Jin; Jeong, Ji Bong; Kim, Ji Won; Kim, Byeong Gwan; Lee, Kook Lae; Lee, Kwang Hyuck; Park, Young Soo; Hwang, Jin-Hyeok; Kim, Jin-Wook; Kim, Nayoung; Lee, Jun Kyu; Jung, Hyun Chae; Yoon, Yong Bum; Song, In Sung

    2006-01-01

    AIM: To investigate histological characteristics of gastric polyps in the Korean population. METHODS: We reviewed endoscopic photographs and medical records of patients with gastric polyps who underwent endoscopic mucosal resection from April 1996 through February 2003. RESULTS: A total of 85 gastric polyps from 74 patients were reviewed. Male-to-female ratio was 1:1.96. Mean age was 59.9 ± 10.8 years. Multiple polyps were observed in 10.8%. Gastric polyps occurred most frequently in the antrum (58.8%). Pathological results on resected specimens were as follows: tubular adenoma 45.9%, hyperplastic polyp 31.8%, inflammatory polyp 9.4%, hamartoma 3.5%, fundic gland polyp 2.4%, tubulovillous adenoma 2.4%, adenocarcinoma 2.4%, dysplasia 1.1%, and mucosal pseudolipomatosis 1.1%. Discrepancy rate between endoscopic biopsy and pathology of resected specimens was 27.1%. There was no relationship between the size of the polyp and concordance rate. CONCLUSION: There is considerable discrepancy in histologic findings between endoscopic forceps biopsy and resected specimens. Approaches to review of the histology of an entire polyp should be performed, especially when an adenoma is suspected. PMID:16810753

  2. Advances in the endoscopic management of pancreatic collections.

    PubMed

    Ruiz-Clavijo, David; de la Higuera, Belen González; Vila, Juan J

    2015-04-16

    Treatment of pancreatic collections has experienced great progress in recent years with the emergence of alternative minimally invasive techniques comparing to the classic surgical treatment. Such techniques have been shown to improve outcomes of morbidity vs surgical treatment. The recent emergence of endoscopic drainage is noteworthy. The advent of endoscopic ultrasonography has been crucial for treatment of these specific lesions. They can be characterized, their relationships with neighboring structures can be evaluated and the drainage guided by this technique has been clearly improved compared with the conventional endoscopic drainage. Computed tomography is the technique of choice to characterize the recently published new classification of pancreatic collections. For this reason, the radiologist's role establishing and classifying in a rigorously manner the collections according to the new nomenclature is essential to making therapeutic decisions. Ideal scenario for comprehensive treatment of these collections would be those centers with endoscopic ultrasound and interventional radiology expertise together with hepatobiliopancreatic surgery. This review describes the different types of pancreatic collections: acute peripancreatic fluid collection, pancreatic pseudocysts, acute necrotic collection and walled-off necrosis; the indications and the contraindications for endoscopic drainage, the drainage technique and their outcomes. The integrated management of pancreatic collections according to their type and evolution time is discussed.

  3. Analysis of Preoperative Airway Examination with the CMOS Video Rhino-laryngoscope.

    PubMed

    Tsukamoto, Masanori; Hitosugi, Takashi; Yokoyama, Takeshi

    2017-05-01

    Endoscopy is one of the most useful clinical techniques in difficult airway management Comparing with the fibroptic endoscope, this compact device is easy to operate and can provide the clear image. In this study, we investigated its usefulness in the preoperative examination of endoscopy. Patients undergoing oral maxillofacial surgery were enrolled in this study. We performed preoperative airway examination by electronic endoscope (The CMOS video rhino-laryngoscope, KARL STORZ Endoscopy Japan, Tokyo). The system is composed of a videoendoscope, a compact video processor and a video recorder. In addition, the endoscope has a small color charge coupled device (CMOS) chip built into the tip of the endoscope. The outer diameter of the tip of this scope is 3.7 mm. In this study, electronic endoscope was used for preoperative airway examination in 7 patients. The preoperative airway examination with electronic endoscope was performed successfully in all the patients except one patient The patient had the symptoms such as nausea and vomiting at the examination. We could perform preoperative airway examination with excellent visualization and convenient recording of video sequence images with the CMOS video rhino-laryngoscope. It might be a especially useful device for the patients of difficult airways.

  4. Endoscopic Plantar Fasciotomy Through Two Medial Portals for the Treatment of Recalcitrant Plantar Fasciopathy.

    PubMed

    Al-Ashhab, Mohamed Ebrahim; Elbegawy, Hossam El-Dein A; Hasan, Hala Ali Abed

    Plantar fasciopathy is a common cause of heel pain. Endoscopic plantar fasciotomy has the advantage of less surgical trauma and rapid recovery. The aim of the present prospective study was to delineate the results of endoscopic plantar fascia release through 2 medial portals. The present study included 2 groups. The first group included 27 feet in 25 patients that had undergone endoscopic plantar fascia release followed up for 19.7 (range 12 to 33) months. The second group, the control group, included 20 feet in 16 patients treated conservatively and followed up for 16.4 (range 12 to 24) months. The results of endoscopic plantar fascia release were superior to the conservative methods. The surgically treated group experienced significantly less pain, activity limitations, and gait abnormality. The presence of a calcaneal spur had no effect on the final postoperative score. In conclusion, endoscopic plantar fascia release through 2 medial portals is an effective procedure for treatment of resistant plantar fasciopathy that fails to respond to conservative management options. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Development of the local magnification method for quantitative evaluation of endoscope geometric distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Cheng, Wei-Chung; Suresh, Nitin; Hua, Hong

    2016-05-01

    With improved diagnostic capabilities and complex optical designs, endoscopic technologies are advancing. As one of the several important optical performance characteristics, geometric distortion can negatively affect size estimation and feature identification related diagnosis. Therefore, a quantitative and simple distortion evaluation method is imperative for both the endoscopic industry and the medical device regulatory agent. However, no such method is available yet. While the image correction techniques are rather mature, they heavily depend on computational power to process multidimensional image data based on complex mathematical model, i.e., difficult to understand. Some commonly used distortion evaluation methods, such as the picture height distortion (DPH) or radial distortion (DRAD), are either too simple to accurately describe the distortion or subject to the error of deriving a reference image. We developed the basic local magnification (ML) method to evaluate endoscope distortion. Based on the method, we also developed ways to calculate DPH and DRAD. The method overcomes the aforementioned limitations, has clear physical meaning in the whole field of view, and can facilitate lesion size estimation during diagnosis. Most importantly, the method can facilitate endoscopic technology to market and potentially be adopted in an international endoscope standard.

  6. 3D Imaging with a Single-Aperture 3-mm Objective Lens: Concept, Fabrication and Test

    NASA Technical Reports Server (NTRS)

    Korniski, Ron; Bae, Sam Y.; Shearn, Mike; Manohara, Harish; Shahinian, Hrayr

    2011-01-01

    There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the-shelf (COTS) components including the ones used in the endoscope objective.

  7. Congenital duodenal web: successful management with endoscopic dilatation

    PubMed Central

    Poddar, Ujjal; Jain, Vikas; Yachha, Surender Kumar; Srivastava, Anshu

    2016-01-01

    Background and study aims: Congenital duodenal web (CDW) is an uncommon cause of duodenal obstruction and endoscopic balloon dilatation has been reported in just eight pediatric cases to date. Here we are reporting three cases of CDW managed successfully with balloon dilatation. Cases and methods: In 2014 we diagnosed three cases of CDW on the basis of typical radiological and endoscopic findings. Endoscopic balloon dilatation was done under conscious sedation with a through-the-scope controlled radial expansion (CRE) balloon. Results: All three children presented late (median age 8 [range 2 – 9] years) with bilious vomiting, upper abdominal distension, and failure to thrive. One of them had associated Down syndrome and another had horseshoe kidney. In all cases, CDW was observed in the second part of the duodenum beyond the ampulla, causing partial duodenal obstruction. After repeated endoscopic dilatation (2 – 4 sessions), all three patients became asymptomatic. None of the patients experienced complications after balloon dilatation. Conclusions: Duodenal diaphragm should be suspected in patients with abdominal distension with bilious vomiting, even in relatively older children. Endoscopic balloon dilatation is a simple and effective method of treating this condition. PMID:27004237

  8. Endoscopic endonasal approach for the treatment of anterior skull base tumours.

    PubMed

    López, Fernando; Suárez, Vanessa; Costales, María; Rodrigo, Juan P; Suárez, Carlos; Llorente, José Luis

    2012-01-01

    The increasing expertise of transnasal endoscopic surgery has recently expanded its indications to include the management of tumours affecting the skull base. We report our experience with endoscopic management of these tumours, emphasising the indications and surgical technique used. A retrospective analysis was performed of patients treated by an endoscopic endonasal approach (EEA) in our department from 2004 until 2011. Sixty-three patients were analysed. We performed an endoscopic craniofacial resection in 32 patients (51%), an expanded EEA in 22 (35%), a transclival approach in 6 (9%) and a transpterygoid approach in 3 (5%). The most frequent benign tumour was nasopharyngeal angiofibroma (24%), while adenocarcinoma (30%) was the most common among malignancies. Mean follow-up was 26 months (range: 6 to 84 months). The complication rate was 5% and resection was complete in 56 cases (89%). The 5-year overall-survival was 71% in patients with malignant tumours and the effectiveness was 100% in benign tumours. Our results support that endoscopic surgery, when properly planned, represents a valid alternative to standard surgical approaches for the management of skull base tumours. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  9. Refinement of ERCP by using the Olympus V-scope system with a 0.025 in. compatible and complete fixable Visiglide(®) guidewire.

    PubMed

    Raithel, Martin; Naegel, Andreas; Seidel, Sebastian; Raithel, Sandra; Diebel, Hiwot; Neurath, Markus F; Maiss, Juergen

    2011-10-01

    Prospective evaluation of the new 0.025 in. Visiglide(®) guidewire to facilitate endoscopic retrograde cholangiopancreaticography using the Olympus V-scope. Interventional endoscopic retrograde cholangiopancreaticography was performed in 9 patients with the Olympus V-scope and the 0.025 in. Visiglide(®) guidewire (VS group), whilst 9 other patients underwent endoscopic retrograde cholangiopancreaticography with a conventional Olympus duodenoscope using 0.035 in. conventional guidewires (controls). Exchange time of accessories, X-ray time, dose and endoscopic retrograde cholangiopancreaticography examination time were investigated. The VS group showed a significantly lower exchange time of endoscopic retrograde cholangiopancreaticography accessories (9; 4-10s, p<0.0001) than controls (29; 19-44s). The Visiglide(®) guidewire was complete fixable by the elevator in 35/36 instrument exchanges (97%) compared to 16/31 exchanges (52%) using conventional guidewires. Single-centre study, small patient numbers, two investigators. Endoscopic retrograde cholangiopancreaticography using the Olympus V-scope with the new 0.025 in. Visiglide(®) guidewire enables a 3-fold faster exchange of accessories due to a nearly complete fixation of the guidewire. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. Cap-assisted endoscopic sclerotherapy for hemorrhoids: Methods, feasibility and efficacy

    PubMed Central

    Zhang, Ting; Xu, Li-Juan; Xiang, Jie; He, Zhi; Peng, Zhao-Yuan; Huang, Guang-Ming; Ji, Guo-Zhong; Zhang, Fa-Ming

    2015-01-01

    AIM: To evaluate the methodology, feasibility, safety and efficacy of a novel method called cap-assisted endoscopic sclerotherapy (CAES) for internal hemorrhoids. METHODS: A pilot study on CAES for grade I to III internal hemorrhoids was performed. Colon and terminal ileum examination by colonoscopy was performed for all patients before starting CAES. Polypectomy and excision of anal papilla fibroma were performed if polyps or anal papilla fibroma were found and assessed to be suitable for resection under endoscopy. CAES was performed based on the requirement of the cap, endoscope, disposable endoscopic long injection needle, enough insufflated air and sclerosing agent. RESULTS: A total of 30 patients with grade I to III internal hemorrhoids was included. The follow-up was more than four weeks. No bleeding was observed after CAES. One (3.33%) patient claimed mild tenesmus within four days after CAES in that an endoscopist performed this procedure for the first time. One hundred percent of patients were satisfied with this novel procedure, especially for those patients who underwent CAES in conjunction with polypectomy or excision of anal papilla fibroma. CONCLUSION: CAES as a novel endoscopic sclerotherapy should be a convenient, safe and effective flexible endoscopic therapy for internal hemorrhoids. PMID:26722615

  11. Endoscopic or surgical step-up approach for infected necrotising pancreatitis: a multicentre randomised trial.

    PubMed

    van Brunschot, Sandra; van Grinsven, Janneke; van Santvoort, Hjalmar C; Bakker, Olaf J; Besselink, Marc G; Boermeester, Marja A; Bollen, Thomas L; Bosscha, Koop; Bouwense, Stefan A; Bruno, Marco J; Cappendijk, Vincent C; Consten, Esther C; Dejong, Cornelis H; van Eijck, Casper H; Erkelens, Willemien G; van Goor, Harry; van Grevenstein, Wilhelmina M U; Haveman, Jan-Willem; Hofker, Sijbrand H; Jansen, Jeroen M; Laméris, Johan S; van Lienden, Krijn P; Meijssen, Maarten A; Mulder, Chris J; Nieuwenhuijs, Vincent B; Poley, Jan-Werner; Quispel, Rutger; de Ridder, Rogier J; Römkens, Tessa E; Scheepers, Joris J; Schepers, Nicolien J; Schwartz, Matthijs P; Seerden, Tom; Spanier, B W Marcel; Straathof, Jan Willem A; Strijker, Marin; Timmer, Robin; Venneman, Niels G; Vleggaar, Frank P; Voermans, Rogier P; Witteman, Ben J; Gooszen, Hein G; Dijkgraaf, Marcel G; Fockens, Paul

    2018-01-06

    Infected necrotising pancreatitis is a potentially lethal disease and an indication for invasive intervention. The surgical step-up approach is the standard treatment. A promising alternative is the endoscopic step-up approach. We compared both approaches to see whether the endoscopic step-up approach was superior to the surgical step-up approach in terms of clinical and economic outcomes. In this multicentre, randomised, superiority trial, we recruited adult patients with infected necrotising pancreatitis and an indication for invasive intervention from 19 hospitals in the Netherlands. Patients were randomly assigned to either the endoscopic or the surgical step-up approach. The endoscopic approach consisted of endoscopic ultrasound-guided transluminal drainage followed, if necessary, by endoscopic necrosectomy. The surgical approach consisted of percutaneous catheter drainage followed, if necessary, by video-assisted retroperitoneal debridement. The primary endpoint was a composite of major complications or death during 6-month follow-up. Analyses were by intention to treat. This trial is registered with the ISRCTN registry, number ISRCTN09186711. Between Sept 20, 2011, and Jan 29, 2015, we screened 418 patients with pancreatic or extrapancreatic necrosis, of which 98 patients were enrolled and randomly assigned to the endoscopic step-up approach (n=51) or the surgical step-up approach (n=47). The primary endpoint occurred in 22 (43%) of 51 patients in the endoscopy group and in 21 (45%) of 47 patients in the surgery group (risk ratio [RR] 0·97, 95% CI 0·62-1·51; p=0·88). Mortality did not differ between groups (nine [18%] patients in the endoscopy group vs six [13%] patients in the surgery group; RR 1·38, 95% CI 0·53-3·59, p=0·50), nor did any of the major complications included in the primary endpoint. In patients with infected necrotising pancreatitis, the endoscopic step-up approach was not superior to the surgical step-up approach in reducing major complications or death. The rate of pancreatic fistulas and length of hospital stay were lower in the endoscopy group. The outcome of this trial will probably result in a shift to the endoscopic step-up approach as treatment preference. The Dutch Digestive Disease Foundation, Fonds NutsOhra, and the Netherlands Organization for Health Research and Development. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. The endoscopic diagnosis of nonerosive reflux disease using flexible spectral imaging color enhancement image: a feasibility trial.

    PubMed

    Miyasaka, M; Hirakawa, M; Nakamura, K; Tanaka, F; Mimori, K; Mori, M; Honda, H

    2011-08-01

    Nonerosive reflux disease (NERD) is classified into grade M (minimal change, endoscopically; erythema without sharp demarcation, whitish turbidity, and/or invisibility of vessels due to these findings) and grade N (normal) in the modified Los Angeles classification system in Japan. However, the classification of grades M and N NERD is not included in the original Los Angeles system because interobserver agreement for the conventional endoscopic diagnosis of grades M or N NERD is poor. Flexible spectral imaging color enhancement (FICE) is a virtual chromoendoscopy technique that enhances mucosal and vascular visibility. The aim of this study is to evaluate whether the endoscopic diagnosis of grades M or N NERD using FICE images is feasible. Between April 2006 and May 2008, 26 NERD patients and 31 controls were enrolled in the present study. First, an experienced endoscopist assessed the color pattern of minimal change in FICE images using conventional endoscopic images and FICE images side-by-side and comparing the proportion of minimal change between the two groups. Second, three blinded endoscopists assessed the presence or absence of minimal change in both groups using conventional endoscopic images and FICE images separately. Intraobserver variability was compared using McNemar's test, and interobserver agreement was described using the kappa value. Minimal changes, such as erythema and whitish turbidity, which were detected using conventional endoscopic images, showed up as navy blue and pink-white, respectively, in color using FICE images in the present FICE mode. The NERD group had a higher proportion of minimal change, compared with the control group (77% and 48%, respectively) (P= 0.033). In all three readers, the detection rates of minimal change using FICE images were greater than those using conventional endoscopic images (P= 0.025, <0.0001, and 0.034 for readers A, B, and C, respectively). The kappa values for all pairs of three readers using FICE images were between 0.683 and 0.812, while those using conventional endoscopic images were between 0.364 and 0.624. Thus, the endoscopic diagnosis of grades M or N NERD using FICE images is feasible and may improve interobserver agreement. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  13. Thalidomide is a therapeutic agent that is effective in inducing and maintaining endoscopic remission in adult CD patients.

    PubMed

    Zhu, Zhenhua; Li, Mengling; Shu, Xu; Bai, Aiping; Long, Shunhua; Liu, Dongsheng; Lu, Nonghua; Zhu, Xuan; Liao, Wangdi

    2017-03-01

    Previous studies have indicated that thalidomide may be effective in achieving clinical remission and response; however, there is a lack of studies on its effect in endoscopic remission. The aim of this study was to assess the efficacy and safety of thalidomide in inducing and maintaining endoscopic remission. A retrospective study was conducted in adult Crohn's disease (CD) patients treated with thalidomide. Patients were assessed based on their medical records. Endoscopy was performed after 4-6 months of thalidomide administration, and the simple endoscopic score for CD (SES-CD) was obtained. Twenty of the 21 (95.2%) eligible patients were recruited. Endoscopic remission was achieved in 7 of the 14 (50%) endoscopy active patients who received thalidomide treatment, whereas 10 (71.4%) patients showed an endoscopy response. The other 6 patients in endoscopic remission still maintained remission after thalidomide treatment. The SES-CD in endoscopy active patients was significantly reduced after thalidomide treatment (P<0.05). A total of 32 adverse events occurred in 17 of the 21 (81.0%) patients. Adverse events resolved spontaneously in 11 (64.7%) patients and resulted in treatment discontinuation and dose reduction in 4 (19.1%) and 2 (9.5%) patients, respectively. Thalidomide therapy is effective in inducing and maintaining endoscopic remission in adult CD patients. However, side effects may limit its clinical use in CD treatment. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. Trigeminocardiac reflex during endoscopic juvenile nasopharyngeal angiofibroma surgery: an appraisal.

    PubMed

    Sharma, Shilpee Bhatia; Janakiram, Trichy Narayanan; Baxi, Hina; Chinnasamy, Balamurugan

    2017-07-01

    Juvenile nasopharyngeal angiofibroma is a locally aggressive benign tumour which has propensity to erode the skull base. The tumour spreads along the pathways of least resistance and is in close proximity to the extracranial part of trigeminal nerve. Advancements in expanded approaches for endoscopic excision of tumours in infratemporal fossa and pterygopalatine fossa increase the vulnerability for the trigeminocardiac reflex. The manipulation of nerve and its branches during tumour dissection can lead to sensory stimulation and thus inciting the reflex. The aim of our study is to report the occurrence of trigeminocardiac reflex in endoscopic excision of juvenile nasopharyngeal angiofibroma. To describe the occurence of trigeminocardiac reflex during endoscopic endonasal excision of juvenile nasopharyngeal angiofibroma. We studied the occurrence of TCR in 15 patients (out of 242 primary cases and 52 revision cases) operated for endoscopic endonasal excision of JNA. The drop in mean arterial blood pressure and heart rate were observed and measured. To the best of our knowledge of English literature, this is the first case series reporting TCR as complication in endoscopic excision of JNA. occurence of this reflex has been mentioned in various occular, maxillofacial surgeries but its occurence during endoscopic excision of JNA has never been reported before. Manifestation of trigeminocardiac reflex during surgery can alter the course of the surgery and is a potential threat to life. It is essential for the anesthetist and surgeons to be familiar with the presentations, preventive measures and management protocols.

  15. Outcomes and Resource Utilization of Endoscopic Mass-Closure Technique for Laryngeal Clefts.

    PubMed

    Balakrishnan, Karthik; Cheng, Esther; de Alarcon, Alessandro; Sidell, Douglas R; Hart, Catherine K; Rutter, Michael J

    2015-07-01

    To compare resource utilization and clinical outcomes between endoscopic mass-closure and open techniques for laryngeal cleft repair. Case series with chart review. Tertiary academic children's hospital. Pediatric patients undergoing repair for Benjamin-Inglis type 1-3 laryngeal clefts over a 15-year period. All 20 patients undergoing endoscopic repair were included. Eight control patients undergoing open repair were selected using matching by age and cleft type. Demographic, clinical, and resource utilization data were collected. Twenty-eight patients were included (20 endoscopic, 8 open). Mean age, rates of tracheostomy and vocal fold immobility, and distribution of cleft types were not different between the 2 groups (all P > .2). Mean operative time (P = .004) and duration of hospital stay (P < .001) were significantly shorter in the endoscopic group. All repairs were intact in both groups at final postoperative endoscopy. Rates of persistent laryngeal penetration or aspiration on swallow study were not different between groups (P = 1.000), although results were available for only 11 patients. Endoscopic laryngeal cleft repair using a mass-closure technique provides a durable result while requiring significantly shorter operative times and hospital stays than open repair and avoiding the potential morbidity of laryngofissure. However, open repair may allow the simultaneous performance of other airway reconstructive procedures and may be a useful salvage technique when endoscopic repair fails. Postoperative swallowing results require further study. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  16. Glucagon Is a Safe and Inexpensive Initial Strategy in Esophageal Food Bolus Impaction.

    PubMed

    Haas, Jason; Leo, Julia; Vakil, Nimish

    2016-03-01

    Controversy exists about the utility of pharmacologic agents and endoscopic technique used for esophageal food bolus impaction. To evaluate the utility of glucagon and the technique used for endoscopic removal, including the rate of success and the adverse events of the techniques. The database of the largest healthcare provider in southeastern Wisconsin was retrospectively reviewed for patients presenting with esophageal food bolus impaction. Data extracted included glucagon administration and its success rate, outcome of radiographic studies, and the endoscopic method of removal and adverse events associated with it, including 30-day mortality. A total of 750 patients were identified with food bolus impaction from 2007 to 2012. Glucagon was administered in 440 patients and was successful in 174 (39.5%). Endoscopic removal was performed in 470 patients and was successful in 469 (99.8%). The push technique was utilized in 209 patients, reduction in the bolus size by piecemeal removal followed by the push technique was utilized in 97 patients, and the pull technique was utilized in 107 patients. There were no perforations with endoscopic removal. Only 4.5% of the X-rays performed reported a possible foreign body within the esophagus. Glucagon was a significantly less-expensive strategy than endoscopic therapy (p < 0.0001). Glucagon is low cost, is moderately effective, and may be considered as an initial strategy. Endoscopic removal regardless of technique is safe and effective. The yield of radiography is poor in the setting of food bolus impaction.

  17. The Prevalence of Barrett Esophagus Diagnosed in the Second Endoscopy

    PubMed Central

    Suna, Nuretdin; Parlak, Erkan; Kuzu, Ufuk Baris; Yildiz, Hakan; Koksal, Aydin Seref; Oztas, Erkin; Sirtas, Zeliha; Yuksel, Mahmut; Aydinli, Onur; Bilge, Zulfikar; Taskiran, Ismail; Sasmaz, Nurgul

    2016-01-01

    Abstract At present, we do not know the exact prevalence of Barrett esophagus (BE) developing later in patients without BE in their first endoscopic screening. The purpose of this study was to determine the prevalence of BE on the second endoscopic examination of patients who had no BE in their first endoscopic examination. The data of the patients older than 18 years who had undergone upper gastrointestinal system endoscopy more than once at the endoscopy unit of our clinic during the last 6 years were retrospectively analyzed. During the last 6 years, 44,936 patients had undergone at least one endoscopic examination. Among these patients, 2701 patients who had more than one endoscopic screening were included in the study. Of the patients, 1276 (47.3%) were females and 1425 (52.7%) were males, with an average age of 54.9 (18–94) years. BE was diagnosed in 18 (0.66%) of the patients who had no BE in the initial endoscopic examination. The patients with BE had reflux symptoms in their medical history and in both endoscopies, they revealed a higher prevalence of lower esophageal sphincter laxity, hiatal hernia, and reflux esophagitis when compared to patients without BE (P < 0.001). Our study showed that in patients receiving no diagnosis of BE on their first endoscopic examination performed for any reason, the prevalence of BE on their second endoscopy within 6 years was very low (0.66%). PMID:27057907

  18. Flexible Ultrathin Endoscope Integrated with Irrigation Suction Apparatus for Assisting Microneurosurgery.

    PubMed

    Otani, Naoki; Morimoto, Yuji; Fujii, Kazuya; Toyooka, Terushige; Wada, Kojiro; Mori, Kentaro

    2017-12-01

    Endoscopy can observe the anatomical components in a deeply located and/or hidden area during neurosurgical procedures under the operating microscope. We have newly developed a flexible ultrathin endoscope integrated with irrigation suction apparatus (FUEISA) to visualize deeply located and/or hidden areas for assisting microneurosurgery. The present study investigated the usefulness of the FUEISA system for direct clipping surgery of cerebral aneurysms. Twenty-one patients underwent microneurosurgery assisted with the FUEISA system for direct clipping of cerebral aneurysms. The flexible ultrathin endoscope (outer diameter 0.75mm) consists of an image guide (6000 dpi) and a light guide, integrated with the irrigation suction apparatus. This endoscopic system was inserted before and after clipping to observe the anatomical conditions surrounding the lesions. In all cases, handling and operation of the FUEISA was technically successful during the surgical procedure. The ultrathin endoscope was adequately integrated with the irrigation suction apparatus in all cases. General anatomy visualization including the lenticulostriate arteries, medial striate arteries, and/or internal carotid artery perforators was possible, and the correct clip positioning and vessel conditions were easily checked. The endoscope revealed that the clip had been positioned incorrectly in one case. No complications associated with the endoscopic system occurred. The FUEISA system can be applied with safe manipulation, which was remarkably useful for confirmation of the presence of perforators and cranial nerves behind the lesions, particularly anatomical components located in deep and/or hidden areas during clipping of cerebral aneurysms. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. "Difficult" Colorectal Polyps - Therapeutic Approach.

    PubMed

    Alecu, M; Simion, L; Ionescu, S; Brătucu, E; Straja, N D

    2015-01-01

    Endoscopic polypectomy is the gold standard in the treatment of colorectal polyps. The importance of polypectomy rests primarily on the fact that polyp-type lesions present a high risk of malignant degeneration, colorectal polyps being able, if left unattended therapeutically, to generate a colorectal cancer (CRC) - a lesion with a far more negative prognosis. Although preferable, endoscopic polypectomy of colorectal polyps is not always possible, multiple factors generating difficulties in performing this therapeutic measure. We performed a retrospective study in the First Surgical Clinic of the "Prof. Dr. Alexandu Trestioreanu" Bucharest Oncology Institute, spanning a period of 3 years (2008-2011), in which time 224 patients were diagnosed by colonoscopy with colorectal polyps, of whom 222 patients benefited from endoscopic polypectomy. The aim of the study was to identify "difficult" polyps and to identify the criteria for endoscopic surgery versus classic surgery as a therapeutic indication. Presence of "difficult" polyps was observed in 37.56% of the patients diagnosed with colorectal polyps. In over 88% of cases endoscopic polypectomy was possible, and for the remaining patients classic surgery was the therapeutic solution opted for. Presence of "difficult" polyps generates inconveniences in performing endoscopic polypectomy, increasing the risk of postoperative complication occurrence, as well as the duration of the operation. If the criteria for characterizing polyps as "difficult" are relatively well-established, the choice between endoscopic and classic surgery as a therapeutic measure is left at the free will of the operating surgeon, with the exception of situations in which classic surgery is resorted to for oncological reasons. Celsius.

  20. Full optical model of micro-endoscope with optical coherence microscopy, multiphoton microscopy and visible capabilities

    NASA Astrophysics Data System (ADS)

    Vega, David; Kiekens, Kelli C.; Syson, Nikolas C.; Romano, Gabriella; Baker, Tressa; Barton, Jennifer K.

    2018-02-01

    While Optical Coherence Microscopy (OCM), Multiphoton Microscopy (MPM), and narrowband imaging are powerful imaging techniques that can be used to detect cancer, each imaging technique has limitations when used by itself. Combining them into an endoscope to work in synergy can help achieve high sensitivity and specificity for diagnosis at the point of care. Such complex endoscopes have an elevated risk of failure, and performing proper modelling ensures functionality and minimizes risk. We present full 2D and 3D models of a multimodality optical micro-endoscope to provide real-time detection of carcinomas, called a salpingoscope. The models evaluate the endoscope illumination and light collection capabilities of various modalities. The design features two optical paths with different numerical apertures (NA) through a single lens system with a scanning optical fiber. The dual path is achieved using dichroic coatings embedded in a triplet. A high NA optical path is designed to perform OCM and MPM while a low NA optical path is designed for the visible spectrum to navigate the endoscope to areas of interest and narrowband imaging. Different tests such as the reflectance profile of homogeneous epithelial tissue were performed to adjust the models properly. Light collection models for the different modalities were created and tested for efficiency. While it is challenging to evaluate the efficiency of multimodality endoscopes, the models ensure that the system is design for the expected light collection levels to provide detectable signal to work for the intended imaging.

  1. "TuNa-saving" endoscopic medial maxillectomy: a surgical technique for maxillary inverted papilloma.

    PubMed

    Pagella, Fabio; Pusateri, Alessandro; Matti, Elina; Avato, Irene; Zaccari, Dario; Emanuelli, Enzo; Volo, Tiziana; Cazzador, Diego; Citraro, Leonardo; Ricci, Giampiero; Tomacelli, Giovanni Leo

    2017-07-01

    The maxillary sinus is the most common site of sinonasal inverted papilloma. Endoscopic sinus surgery, in particular endoscopic medial maxillectomy, is currently the gold standard for treatment of maxillary sinus papilloma. Although a common technique, complications such as stenosis of the lacrimal pathway and consequent development of epiphora are still possible. To avoid these problems, we propose a modification of this surgical technique that preserves the head of the inferior turbinate and the nasolacrimal duct. A retrospective analysis was performed on patients treated for maxillary inverted papilloma in three tertiary medical centres between 2006 and 2014. Pedicle-oriented endoscopic surgery principles were applied and, in select cases where the tumour pedicle was located on the anterior wall, a modified endoscopic medial maxillectomy was carried out as described in this paper. From 2006 to 2014 a total of 84 patients were treated. A standard endoscopic medial maxillectomy was performed in 55 patients (65.4%), while the remaining 29 (34.6%) had a modified technique performed. Three recurrences (3/84; 3.6%) were observed after a minimum follow-up of 24 months. A new surgical approach for select cases of maxillary sinus inverted papilloma is proposed in this paper. In this technique, the endoscopic medial maxillectomy was performed while preserving the head of the inferior turbinate and the nasolacrimal duct ("TuNa-saving"). This technique allowed for good visualization of the maxillary sinus, good oncological control and a reduction in the rate of complications.

  2. Recurrent upside-down stomach after endoscopic repositioning and gastropexy treated by laparoscopic surgery.

    PubMed

    Toyota, Kazuhiro; Sugawara, Yuji; Hatano, Yu

    2014-01-01

    Patients with an upside-down stomach usually receive surgical treatment. In high-risk patients, endoscopic repositioning and gastropexy can be performed. However, the risk of recurrence after endoscopic treatment is not known. We treated a case of recurrent upside-down stomach after endoscopic therapy that indicated the limits of endoscopic treatment and risk of recurrence. An 88-year-old woman was treated three times for vomiting in the past. She presented to our hospital with periodic vomiting and an inability to eat, and a diagnosis of upside-down stomach was made. Endoscopic repositioning and gastropexy were performed. The anterior stomach wall was fixed to the abdominal wall in three places as widely as possible. Following treatment, she became symptom-free. Three months later, she was hospitalized again because of a recurrent upside-down stomach. Laparoscopic repair of hernias and gastropexy was performed. Using a laparoscope, two causes of recurrence were found. One cause was that the range of adherence between the stomach and the abdominal wall was narrow (from the antrum only to the lower corpus of stomach), so the upper corpus of stomach was rotated and herniated into the esophageal hiatus. The other cause was adhesion between the omentum and the esophageal hiatus which caused the stomach to rotate and repeatedly become herniated. Although endoscopic treatment for upside-down stomach can be a useful alternative method in high-risk patients, its ability to prevent recurrence is limited. Moreover, a repeated case caused by adhesions has risks of recurrence.

  3. An examination of the relationship between the endoscopic appearance of duodenitis and the histological findings in patients with epigastric pain

    PubMed Central

    Lewis, Stephen; Stableforth, William; Awasthi, Rachana; Awasthi, Ashish; Pitts, Narrie; Ottaway, Janet; Sherwood, Anthea; Robertson, Neil; Cochrane, Sean; Wilkinson, Stephen

    2012-01-01

    The endoscopic appearance of duodenitis is a common finding in patients undergoing endoscopy because of epigastric pain however, the relationship of the visual findings to histology is poorly defined. We set out to ascertain if there was a correlation between the endoscopic and histological appearances of the duodenal mucosa. Consecutive patients with epigastric pain referred for diagnostic gastroduodenoscopy were studied. The visual appearances of ‘duodenitis’ (erythema, erosions and sub-epithelial haemorrhage) were reported independently by two endoscopists. Duodenal biopsies were taken and assessed for: neutrophil infiltrate, mononuclear infiltrate, gastric metaplasia, villous atrophy and a breach in the mucosa. H pylori status was determined. Of the 93 patients with endoscopic features of duodenitis an increase in histological markers of inflammation was found in 75 (81%). However, histological inflammation was absent or minimal in 68 (73%). Conversely, biopsies from normal-looking mucosa revealed histological evidence of inflammation in 26 (27%). For patients with the endoscopic features of duodenitis the positive & negative predictive value for neutrophilic infiltrate was 39% and 98% respectively. Biopsies from erosions confirmed a breach in the mucosa in only 2 of 40 patients. Neutrophilic infiltrate occurred with NSAI ingestion and infection with H pylori. The endoscopic appearance of the duodenal mucosa is unreliable in determining the presence of histological inflammation. The endoscopic appearance of ‘erosions’ is not usually associated with a mucosal breach. PMID:22949941

  4. Development of terahertz endoscopic system for cancer detection

    NASA Astrophysics Data System (ADS)

    Doradla, Pallavi; Alavi, Karim; Joseph, Cecil S.; Giles, Robert H.

    2016-02-01

    Terahertz (THz) imaging is emerging as a robust platform for a myriad of applications in the fields of security, health, astronomy and material science. The terahertz regime with wavelengths spanning from microns to millimeters is a potentially safe and noninvasive medical imaging modality for detecting cancers. Endoscopic imaging systems provide high flexibility in examining the interior surfaces of an organ or tissue. Researchers have been working on the development of THz endoscopes with photoconductive antennas, which necessarily operate under high voltage, and require at least two channels to measure the reflected signal from the specimen. This manuscript provides the design and imperative steps involved in the development of a single-channel terahertz endoscopic system. The continuous-wave terahertz imaging system utilizes a single flexible terahertz waveguide channel to transmit and collect the back reflected intrinsic terahertz signal from the sample and is capable of operation in both transmission and reflection modalities. To determine the feasibility of using a terahertz endoscope for cancer detection, the co- and cross-polarized terahertz remittance from human colonic tissue specimens were collected at 584 GHz frequency. The two dimensional terahertz images obtained using polarization specific detection exhibited intrinsic contrast between cancerous and normal regions of fresh colorectal tissue. The level of contrast observed using endoscopic imaging correlates well with the contrast levels observed in the free space ex vivo terahertz reflectance studies of human colonic tissue. The prototype device developed in this study represents a significant step towards clinical endoscopic application of THz technology for in vivo colon cancer screening.

  5. Gynaecological Endoscopic Surgical Education and Assessment. A diploma programme in gynaecological endoscopic surgery.

    PubMed

    Campo, Rudi; Wattiez, Arnaud; Tanos, Vasilis; Di Spiezio Sardo, Attilio; Grimbizis, Grigoris; Wallwiener, Diethelm; Brucker, Sara; Puga, Marco; Molinas, Roger; O'Donovan, Peter; Deprest, Jan; Van Belle, Yves; Lissens, Ann; Herrmann, Anja; Tahir, Mahmood; Benedetto, Chiara; Siebert, Igno; Rabischong, Benoit; De Wilde, Rudy Leon

    2016-04-01

    In recent years, training and education in endoscopic surgery has been critically reviewed. Clinicians, both surgeons as gynaecologist who perform endoscopic surgery without proper training of the specific psychomotor skills are at higher risk to increased patient morbidity and mortality. Although the apprentice-tutor model has long been a successful approach for training of surgeons, recently, clinicians have recognised that endoscopic surgery requires an important training phase outside the operating theatre. The Gynaecological Endoscopic Surgical Education and Assessment programme (GESEA), recognises the necessity of this structured approach and implements two separated stages in its learning strategy. In the first stage, a skill certificate on theoretical knowledge and specific practical psychomotor skills is acquired through a high stake exam; in the second stage, a clinical programme is completed to achieve surgical competence and receive the corresponding diploma. Three diplomas can be awarded: (a) the Bachelor in Endoscopy; (b) the Minimally Invasive Gynaecological Surgeon (MIGS); and (c) the Master level. The Master level is sub-divided into two separate diplomas: the Master in Laparoscopic Pelvic Surgery and the Master in Hysteroscopy. The complexity of modern surgery has increased the demands and challenges to surgical education and the quality control. This programme is based on the best available scientific evidence and it counteracts the problem of the traditional surgical apprentice tutor model. It is seen as a major step toward standardization of endoscopic surgical training in general. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. KTP laser assisted endoscopic tissue fibrin glue biocauterization for congenital pyriform sinus fistula in children.

    PubMed

    Huang, Yun-Chen; Peng, Steve Shinn-Forng; Hsu, Wei-Chung

    2016-06-01

    This study aims to assess the efficacy of a novel endoscopic management for congenital pyriform sinus fistula (CPSF) using potassium titanyl phosphate (KTP) laser assisted endoscopic tissue fibrin glue biocauterization in children. From 2010 to 2014, a total of 5 children with recurrent or acute suppurative thyroiditis or neck abscess secondary to CPSF were enrolled retrospectively in this study. Mean age at the first time of endoscopic biocauterization was 6.2 ± 0.7 (5-7) years. The barium swallow study detected a fistula in four cases. Endoscopy identified an internal opening at the pyriform sinus in all cases with four on the left side and one on the right side. All patients underwent KTP laser assisted endoscopic tissue fibrin glue biocauterization as treatment for CPSF. Only one case required the second endoscopic procedure due to fluctuation of symptoms. Post-endoscopic follow-up duration of these patients was 24.6 ± 11.6 (7-36) months. Neither complications nor recurrences were noted during follow-up in all patients. For children presenting with repeated acute suppurative thyroiditis or neck infections, clinicians should highly suspect the possibility of CPSF. Endoscopy should be performed not only to confirm the diagnosis but also could be served as an initial treatment modality of biocauterization by KTP laser and tissue fibrin glue, which was demonstrated as a less invasive, safe, and effective method in children. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. History, Current Situation, and Future Development of Endoscopic Neurosurgery in China.

    PubMed

    Li, Chuzhong; Zhu, Haibo; Zong, Xuyi; Wang, Xinsheng; Gui, Songbai; Zhao, Peng; Zhang, Yazhuo

    2018-02-01

    During the past few decades, Chinese endoscopic neurosurgery has rapidly developed in synchrony with the rest of the world. The aim of this article is to review the development of Chinese endoscopic neurosurgery, including its birth, growth, current situation, and prospects. The history of Chinese endoscopic neurosurgery development can be divided into 3 stages: cognition and initial stage (1964-1995), exploration and maturity stage (1995-2006), and rapid development and promotion stage (2006-present). In the first stage, we mainly began to become aware of endoscopic neurosurgery from the translation and review of literature. In the mid to late 1990s, Chinese neurosurgery pioneers began using neuroendoscopic techniques. In the following decade, many leading neurosurgeons made persistent efforts to push the development of Chinese endoscopic neurosurgery forward, focusing on advocating for and promoting and popularizing neuroendoscopic technology. In the rapid development and promotion stage, many representative national and regional neurosurgical centers became skilled and efficient in the application of neuroendoscopic technology and became new advocates of the technology. The number of cases, level of technology, and treatment effectiveness are gradually nearing international standards. However, future development requires promotion of balanced development to decrease regional disparities, further strengthen international exchanges, follow the latest developments, and constantly innovate for continuous improvement. Following the dramatic efforts of several pioneers, development of Chinese endoscopic neurosurgery has been considerable, and it has become an important component of neurosurgery worldwide. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Safety and utility of capsule endoscopy for infants and young children

    PubMed Central

    Oikawa-Kawamoto, Manari; Sogo, Tsuyoshi; Yamaguchi, Takeshi; Tsunoda, Tomoyuki; Kondo, Takeo; Komatsu, Haruki; Inui, Ayano; Fujisawa, Tomoo

    2013-01-01

    AIM: To assess the safety and utility of capsule endoscopy (CE) for children who are unable to swallow the capsule endoscope. METHODS: The medical records of all of the children who underwent CE between 2010 and 2012 were retrospectively reviewed. The patients were divided into 2 groups: group A included patients who were unable to swallow the capsule endoscope, and group B included patients who were able to swallow it. For the patients who were unable to swallow the capsule endoscope, it was placed in the duodenum endoscopically. The small bowel transit time, endoscopic diagnosis and complications of the 2 groups were compared. RESULTS: During the study period, 28 CE procedures were performed in 26 patients. Group A included 11 patients with a median age of 2 years (range 10 mo-9 years), and group B included 15 patients with a median age of 12 years (range 8 years-16 years). The lightest child in the study weighed 7.9 kg. The detection rates did not differ between the 2 groups. The median small bowel transit time was 401 min (range 264-734 min) in group A and 227 min (range 56-512 min) in group B (P = 0.0078). No serious complications, including capsule retention, occurred. No significant mucosal trauma occurred in the pharynx, esophagus, stomach or duodenum when the capsule was introduced using an endoscope. CONCLUSION: CE is a safe and useful procedure for infants and young children who are unable to swallow the capsule endoscope. PMID:24363526

  9. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    PubMed

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  10. Endoscopic Sex Identification in Chelonians and Birds (Psittacines, Passerines, and Raptors).

    PubMed

    Divers, Stephen J

    2015-09-01

    Despite the advent of DNA probes for sex identification of many avian and some reptile species, clinicians involved with zoos, conservation projects, or breeders may still be asked to perform "surgical sexing." This article describes the practical approach to performing endoscopic sex identification in psittacines and chelonians, including patient preparation, anesthesia, and endoscopic procedure. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Novel strategy for prevention of esophageal stricture after endoscopic surgery.

    PubMed

    Mizutani, Taro; Tadauchi, Akimitsu; Arinobe, Manabu; Narita, Yuji; Kato, Ryuji; Niwa, Yasumasa; Ohmiya, Naoki; Itoh, Akihiro; Hirooka, Yoshiki; Honda, Hiroyuki; Ueda, Minoru; Goto, Hidemi

    2010-01-01

    Recently, novel endoscopic surgery, including endoscopic submucosal dissection (ESD), was developed to resect a large superficial gastrointestinal cancer. However, circumferential endoscopic surgery in the esophagus can lead to esophageal stricture that affects the patient's quality of life. This major complication is caused by scar formation, and develops during the two weeks after endoscopic surgery. We hypothesized that local administration of a controlled release anti-scarring agent can prevent esophageal stricture after endoscopic surgery. The aims of this study were to develop an endoscopically injectable anti-scarring drug delivery system, and to verify the efficacy of our strategy to prevent esophageal stricture. We focused on 5-Fluorouracil (5-FU) as an anti-scarring agent, which has already been shown to be effective not only for treatment of cancers, but also for treatment of hypertrophic skin scars. 5-FU was encapsulated by liposome, and then mixed with injectable 2% atelocollagen (5FLC: 5FU-liposome-collagen) to achieve sustained release. An in vitro 5-FU releasing test from 5FLC was performed using high-performance liquid chromatography (HPLC). Inhibition of cell proliferation was investigated using normal human dermal fibroblast cells (NHDF) with 5FLC. In addition, a canine esophageal mucosal resection was carried out, and 5FLC was endoscopically injected into the ulcer immediately after the operation, and compared with a similar specimen injected with saline as a control. 5-FU was gradually released from 5FLC for more than 2 weeks in vitro. The solution of 5-FU released from 5FLC inhibited NHDF proliferation more effectively than 5-FU alone. In the canine model, no findings of stricture were observed in the 5FLC-treated dog at 4 weeks after the operation and no vomiting occurred. In contrast, marked esophageal strictures were observed with repeated vomiting in the control group. Submucosal fibrosis was markedly reduced histologically in the 5FLC-treated dog compared with the control. 5FLC showed sustained release of 5-FU and decreased cell proliferation in vitro. The clinically relevant canine model demonstrated that local endoscopic injection of 5FLC can prevent post-operative esophageal stricture. These results suggest that our strategy may be useful for preventing post-operative esophageal stricture.

  12. Systemic inflammatory response after endoscopic (TEP) vs Shouldice groin hernia repair.

    PubMed

    Schwab, R; Eissele, S; Brückner, U B; Gebhard, F; Becker, H P

    2004-08-01

    Endoscopic techniques are commonly used for many different types of surgery. It is claimed that videoendoscopic procedures have the advantage of being less traumatic and of offering higher postoperative patient comfort than conventional open techniques. The extent of tissue trauma can be evaluated on the basis of the inflammatory response observed in the wake of surgery. Available studies that have compared endoscopic and conventional techniques suggest that endoscopic cholecystectomy, laparoscopic colorectal resection, and thoracoscopic pulmonary resection have immunologic advantages over conventional approaches. The objective of this prospective study was to determine whether endoscopic hernia repair techniques are also preferable to conventional procedures and to what extent the anesthetic technique (local or general anesthesia) influences the postoperative inflammatory response. For this purpose, biochemical monitoring of cytokine activity [C-reactive protein (CRP), prostaglandin F1alpha (PGF1alpha), neopterin, interleukin-6 (IL-6)] was done prospectively in 101 patients [totally extraperitoneal approach (TEP) n=32, unilateral n=12, bilateral n=20; Shouldice n=69, local anesthesia (LA) n=23, general anesthesia (GA) n=46] before and until 3 days after surgery. The parameters IL-6 and PGF1alpha suggested that the immune trauma immediately after surgery was significantly higher in the group of patients with endoscopic hernia repair than in the group of patients who received a Shouldice repair. No significant differences were observed after the first postoperative day. A comparison between the TEP group and the patients who received conventional surgery under local anesthesia showed that the TEP approach was also associated with a higher postoperative neopterin level. Within the first 3 days after surgical intervention, bilateral endoscopic hernia repair induced no significantly higher inflammatory response than the surgical treatment of unilateral conditions. The anesthetic procedure that was used in the Shouldice operation had no significant effect on inflammatory response. Unlike other types of endoscopic surgery, the repair of groin hernias using an endoscopic technique cannot be regarded as a minimally invasive procedure that is less traumatic than conventional approaches. Instead, the conventional Shouldice procedure appears to cause the lowest inflammatory response and to be the least traumatic approach to hernia repair, especially when it is performed under local anesthesia.

  13. Outcomes after endoscopic resection of large laterally spreading lesions of the papilla and conventional ampullary adenomas are equivalent.

    PubMed

    Klein, Amir; Qi, Zhengyan; Bahin, Farzan F; Awadie, Halim; Nayyar, Dhruv; Ma, Michael; Voermans, Rogier P; Williams, Stephen J; Lee, Eric; Bourke, Michael J

    2018-05-16

     Endoscopic resection of ampullary adenomas is a safe and effective alternative to surgical resection. A subgroup of patients have large laterally spreading lesions of the papilla Vateri (LSL-P), which are frequently managed surgically. Data on endoscopic resection of LSL-P are limited and long-term outcomes are unknown. The aim of this study was to compare the outcomes of endoscopic resection of LSL-P with those of standard ampullary adenomas.  A retrospective analysis of a prospectively collected and maintained database was conducted. LSL-P was defined as extension of the lesion ≥ 10 mm from the edge of the ampullary mound. Piecemeal endoscopic mucosal resection of the laterally spreading component was followed by resection of the ampulla. Patient, lesion, and procedural data, as well as results of endoscopic follow-up, were collected.  125 lesions were resected. Complete endoscopic resection was achieved in 97.6 % at the index procedure (median lesion size 20 mm, interquartile range [IQR] 13 - 30 mm). Compared with ampullary adenomas, LSL-Ps were significantly larger (median 35 mm vs. 15 mm), contained a higher rate of advanced pathology (38.6 % vs. 18.5 %), and had higher rates of intraprocedural bleeding (50 % vs. 24.7 %) and delayed bleeding (25.0 % vs. 12.3 %). Both groups had similar rates of histologically proven recurrence at first surveillance (16.4 % vs. 17.9 %). Median follow-up for the entire cohort was 18.5 months. For patients with at least two surveillance endoscopies (n = 68; median follow-up 29 months, IQR 18 - 48 months), 95.6 % were clear of disease and considered cured.  LSL-P can be resected endoscopically with comparable outcomes to standard ampullectomy, albeit with a higher risk of bleeding. Endoscopic treatment should be considered as an alternative to surgical resection, even for large LSL-P. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Cost-Minimization Analysis of Open and Endoscopic Carpal Tunnel Release.

    PubMed

    Zhang, Steven; Vora, Molly; Harris, Alex H S; Baker, Laurence; Curtin, Catherine; Kamal, Robin N

    2016-12-07

    Carpal tunnel release is the most common upper-limb surgical procedure performed annually in the U.S. There are 2 surgical methods of carpal tunnel release: open or endoscopic. Currently, there is no clear clinical or economic evidence supporting the use of one procedure over the other. We completed a cost-minimization analysis of open and endoscopic carpal tunnel release, testing the null hypothesis that there is no difference between the procedures in terms of cost. We conducted a retrospective review using a private-payer and Medicare Advantage database composed of 16 million patient records from 2007 to 2014. The cohort consisted of records with an ICD-9 (International Classification of Diseases, Ninth Revision) diagnosis of carpal tunnel syndrome and a CPT (Current Procedural Terminology) code for carpal tunnel release. Payer fees were used to define cost. We also assessed other associated costs of care, including those of electrodiagnostic studies and occupational therapy. Bivariate comparisons were performed using the chi-square test and the Student t test. Data showed that 86% of the patients underwent open carpal tunnel release. Reimbursement fees for endoscopic release were significantly higher than for open release. Facility fees were responsible for most of the difference between the procedures in reimbursement: facility fees averaged $1,884 for endoscopic release compared with $1,080 for open release (p < 0.0001). Endoscopic release also demonstrated significantly higher physician fees than open release (an average of $555 compared with $428; p < 0.0001). Occupational therapy fees associated with endoscopic release were less than those associated with open release (an average of $237 per session compared with $272; p = 0.07). The total average annual reimbursement per patient for endoscopic release (facility, surgeon, and occupational therapy fees) was significantly higher than for open release ($2,602 compared with $1,751; p < 0.0001). Our data showed that the total average fees per patient for endoscopic release were significantly higher than those for open release, although there currently is no strong evidence supporting better clinical outcomes of either technique. Value-based health-care models that favor delivering high-quality care and improving patient health, while also minimizing costs, may favor open carpal tunnel release.

  15. A Randomized Controlled Trial Comparing Endoscopic-Assisted Versus Open Neck Tissue Expander Placement in Reconstruction of Post-Burn Facial Scar Deformities.

    PubMed

    As'adi, Kamran; Emami, Seyed Abolhassan; Salehi, Seyed Hamid; Shoar, Saeed

    2016-08-01

    Tissue expansion has evolved reconstruction surgery by providing a great source of additional tissue for large skin defects. Nevertheless, wide application of tissue expander reconstruction is challenging due to high complication rates and uncertainty about final outcomes. Recently, endoscopy has shown promise in reconstructive surgeries using tissue expander placement. This study aimed to compare outcomes between open and endoscopic-assisted neck tissue expander placement in reconstruction of post-burn facial scar deformities. Through a randomized clinical trial, 63 patients with facial burn scars were assigned to an open group or endoscopic group for placement of 81 tissue expanders. The complication rate, operative time, length of hospital stay, and time to full expansion were compared between the two groups. Thirty-one patients were assigned to the open group and 32 patients to the endoscopic group. The average operative time was significantly reduced in the endoscopic group compared with the open group (42.2 ± 3.6, 56.5 ± 4.5 min, p < 0.05). The complication rate was significantly lower in the endoscopic group than the open group (6 vs. 16, p < 0.05). Hospital stay was also significantly diminished from 26.3 ± 7.7 h in open group to 7.4 ± 4.5 h in endoscopic group (p < 0.0001). There was a significant reduction in time to full expansion in the endoscopic group as compared with the open group (93.5 ± 10.2 vs. 112.1 ± 14.2 days, p = 0.002). Endoscopic neck tissue expander placement significantly reduced operative time, the postoperative complication rate, length of hospital stay, and time to achieve full expansion and allowed early initiation of expansion and remote placement of the port in relation to the expander pocket. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  16. Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Xiongbiao, E-mail: xluo@robarts.ca, E-mail: Ying.Wan@student.uts.edu.au; Wan, Ying, E-mail: xluo@robarts.ca, E-mail: Ying.Wan@student.uts.edu.au; He, Xiangjian

    Purpose: Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization. Methods: The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) asmore » a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor’s) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm. Results: The experimental results demonstrate that the authors’ proposed method provides a more accurate and robust endoscopic guidance framework than state-of-the-art methods. The average guidance accuracy of the authors’ framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29. Conclusions: A robust electromagnetically guided endoscopy framework was proposed on the basis of an enhanced particle swarm optimization method with using the current observation information and adaptive evolutionary factors. The authors proposed framework greatly reduced the guidance errors from (4.3, 7.8) to (3.0 mm, 5.6°), compared to state-of-the-art methods.« less

  17. Limited endoscopic transsphenoidal approach for cavernous sinus biopsy: illustration of 3 cases and discussion.

    PubMed

    Graillon, T; Fuentes, S; Metellus, P; Adetchessi, T; Gras, R; Dufour, H

    2014-01-01

    Advances in transsphenoidal surgery and endoscopic techniques have opened new perspectives for cavernous sinus (CS) approaches. The aim of this study was to assess the advantages and disadvantages of limited endoscopic transsphenoidal approach, as performed in pituitary adenoma surgery, for CS tumor biopsy illustrated with three clinical cases. The first case was a 46-year-old woman with a prior medical history of parotid adenocarcinoma successfully treated 10 years previously. The cavernous sinus tumor was revealed by right third and sixth nerve palsy and increased over the past three years. A tumor biopsy using a limited endoscopic transsphenoidal approach revealed an adenocarcinoma metastasis. Complementary radiosurgery was performed. The second case was a 36-year-old woman who consulted for diplopia with right sixth nerve palsy and amenorrhea with hyperprolactinemia. Dopamine agonist treatment was used to restore the patient's menstrual cycle. Cerebral magnetic resonance imaging (MRI) revealed a right sided CS tumor. CS biopsy, via a limited endoscopic transsphenoidal approach, confirmed a meningothelial grade 1 meningioma. Complementary radiosurgery was performed. The third case was a 63-year-old woman with progressive installation of left third nerve palsy and visual acuity loss, revealing a left cavernous sinus tumor invading the optic canal. Surgical biopsy was performed using an enlarged endoscopic transsphenoidal approach to the decompress optic nerve. Biopsy results revealed a meningothelial grade 1 meningioma. Complementary radiotherapy was performed. In these three cases, no complications were observed. Mean hospitalization duration was 4 days. Reported anatomical studies and clinical series have shown the feasibility of reaching the cavernous sinus using an endoscopic endonasal approach. Trans-foramen ovale CS percutaneous biopsy is an interesting procedure but only provides cell analysis results, and not tissue analysis. However, radiotherapy and radiosurgery have proven effective for SC meningiomas. When histological diagnosis is required, limited endoscopic transsphenoidal approach appears as a safe, fast, and useful alternative to the classical endocranial approach. Also, a tailored enlargement of the approach could be performed if optic nerve decompression is required. The feasibility of CS endoscopic transsphenoidal biopsy has prompted us to consider CS biopsy when the diagnosis of CS meningioma is uncertain. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Survival study of natural orifice translumenal endoscopic surgery for rectosigmoid resection using transanal endoscopic microsurgery with or without transgastric endoscopic assistance in a swine model.

    PubMed

    Sylla, Patricia; Sohn, Dae Kyung; Cizginer, Sevdenur; Konuk, Yusuf; Turner, Brian G; Gee, Denise W; Willingham, Field F; Hsu, Maylee; Mino-Kenudson, Mari; Brugge, William R; Rattner, David W

    2010-08-01

    The feasibility of transanal rectosigmoid resection with transanal endoscopic microsurgery (TEM) was previously demonstrated in a swine nonsurvival model in which transgastric endoscopic assistance also was shown to extend the length of colon mobilized transanally. A 2-week survival study evaluating transanal endoscopic rectosigmoid resection with stapled colorectal anastomosis was conducted with swine using the transanal approach alone (TEM group, n = 10) or a transanal approach combined with transgastric endoscopic assistance (TEM + TG group, n = 10). Gastrotomies were created using a needleknife and balloon dilation, then closed using prototype T-tags. Outcomes were evaluated and compared between the groups using Student's t-test and Fisher's exact test. Relative to the TEM group, the average length of rectosigmoid mobilized in the TEM + TG group was 15.6 versus 10.5 cm (p < 0.0005), the length of the resected specimen was 9 versus 6.2 cm (p < 0.0005), and the mean operative time was 254.5 versus 97.5 min (p < 0.0005). Intraoperatively, no organ injury or major bleeding was noted. Two T-tag misfires occurred during gastrotomy closure and four small staple line defects requiring transanal repair including one in the TEM group and three in the TEM + TG group (p = 0.2). Postoperatively, there was no mortality, and the animals gained an average of 3.4 lb. Two major complications (10%) were identified at necropsy in the TEM + TG group including an intraabdominal abscess and an abdominal wall hematoma related to T-tag misfire. Gastrotomy closure sites and colorectal anastomoses were all grossly healed, with adhesions noted in 60 and 70% and microabscesses in 50 and 20% of the gastrotomy sites and colorectal anastomoses, respectively. Natural orifice translumenal endoscopic surgery (NOTES) for rectosigmoid resection using TEM with or without transgastric endoscopic assistance is feasible and associated with low morbidity in a porcine survival model. Transgastric assistance significantly prolongs the operative time but extends the length of the rectosigmoid mobilized transanally, with a nonsignificant increase in complication rates related to gastrotomy creation.

  19. [The recent news in endoscopic surgery: a review of the literature and meta-analysis].

    PubMed

    Klimenko, K É

    2012-01-01

    During a few recent years, endonasal surgery has become the principal tool for the operative treatment of many pathologies affecting the base of the skull. The present work was designed to estimate the possibilities of using endoscopic endonasal surgery to treat sinus and skull base lesions and illustrate the recent progress in the development of endoscopic equipment and instrumentation. The meta-analysis of the results of on-going research on the application of the endonasal endoscopic technology is described with the special emphasis on the plastic treatment of liquor fistulas, removal of juvenile nasopharyngeal angiofibromas, treatment of pathological changes in the clivial region and odontoid cervicomedullary junction.

  20. Endoscopic Submucosal Dissection of Rectal Cancer Close to the Dentate Line Accompanied by Mucosal Prolapse Syndrome

    PubMed Central

    Nakamura, Kenji; Ishii, Naoki; Suzuki, Koyu; Fukuda, Katsuyuki

    2018-01-01

    A 37-year-old man presented to our hospital for early rectal cancer accompanied by mucosal prolapse syndrome. Biopsy confirmed an adenocarcinoma, and endoscopic ultrasonography indicated proximity to the dentate line but no submucosal invasion. The tumor was removed en bloc via endoscopic submucosal dissection without complications, and its margin was free of tumor cells. The total procedure duration was 37 minutes, and the resected specimen measured 23 × 13 mm. There was no recurrence during the 3-year observation period. Although close to the dentate line and accompanied by mucosal prolapse syndrome, a rectal cancer lesion was safely resected en bloc using endoscopic submucosal dissection. PMID:29430468

  1. Anterior trans-frontal endoscopic resection of third-ventricle colloid cyst: how I do it.

    PubMed

    Nasi, Davide; Iaccarino, Corrado; Romano, Antonio

    2017-06-01

    The endoscopic technique has been recognised as a viable and safe alternative to microsurgery for the treatment of third-ventricle colloid cyst. However, the standard precoronal endoscopic approach does not always provide an adequate visualisation of the attachment of the cyst to the velum interpositum. Using a more anterior approach, it is easier to reach the roof of the cyst and its possible adherences with the tela choroidea. The authors describe step by step the anterior trans-frontal endoscopic approach for management of third ventricle colloid cyst. The described approach has shown to be safe, quick and effective for the treatment of third-ventricle colloid cyst.

  2. Endoscopic Surgery for Symptomatic Unicameral Bone Cyst of the Proximal Femur

    PubMed Central

    Miyamoto, Wataru; Takao, Masato; Yasui, Youichi; Miki, Shinya; Matsushita, Takashi

    2013-01-01

    Recently, surgical treatment of a symptomatic unicameral cyst of the proximal femur has been achieved with less invasive procedures than traditional open curettage with an autologous bone graft. In this article we introduce endoscopic surgery for a symptomatic unicameral cyst of the proximal femur. The presented technique, which includes minimally invasive endoscopic curettage of the cyst and injection of a bone substitute, not only minimizes muscle damage around the femur but also enables sufficient curettage of the fibrous membrane in the cyst wall and the bony septum through direct detailed visualization by an endoscope. Furthermore, sufficient initial strength after curettage can be obtained by injecting calcium phosphate cement as a bone substitute. PMID:24892010

  3. Endoscopic Surgery for Symptomatic Unicameral Bone Cyst of the Proximal Femur.

    PubMed

    Miyamoto, Wataru; Takao, Masato; Yasui, Youichi; Miki, Shinya; Matsushita, Takashi

    2013-11-01

    Recently, surgical treatment of a symptomatic unicameral cyst of the proximal femur has been achieved with less invasive procedures than traditional open curettage with an autologous bone graft. In this article we introduce endoscopic surgery for a symptomatic unicameral cyst of the proximal femur. The presented technique, which includes minimally invasive endoscopic curettage of the cyst and injection of a bone substitute, not only minimizes muscle damage around the femur but also enables sufficient curettage of the fibrous membrane in the cyst wall and the bony septum through direct detailed visualization by an endoscope. Furthermore, sufficient initial strength after curettage can be obtained by injecting calcium phosphate cement as a bone substitute.

  4. The Regulatory Perspectives on Endoscopic Devices for Obesity.

    PubMed

    Marrone, April K; Antonino, Mark J; Silverstein, Joshua S; Betz, Martha W; Venkataraman-Rao, Priya; Golding, Martin; Cordray, Diane; Cooper, Jeffrey W

    2017-04-01

    The recent increase in US Food and Drug Administration-approved weight-loss devices has diversified obesity treatment options. The regulatory pathways for endoscopically placed weight-loss devices and considerations for clinical trials are discussed, including the benefit-risk paradigm intended to aid in weight-loss-device trial development. Also discussed is the benefit-risk analysis of recently approved endoscopic devices. A strategic priority of the FDA Center for Devices and Radiological Health is to increase the use of patient input in decision making. Thus, we consider how endoscopic weight-loss devices with profiles similar to those that have been approved may be viewed in a patient preference study. Published by Elsevier Inc.

  5. Helicobacter pylori status and associated gastroscopic diagnoses in a tertiary hospital endoscopy population in Rwanda.

    PubMed

    Walker, Timothy D; Karemera, Martin; Ngabonziza, Francois; Kyamanywa, Patrick

    2014-05-01

    The study was undertaken to document the prevalence of Helicobacter pylori and endoscopic diagnoses in Rwandans presenting for gastroscopy. We studied an endoscopic database containing 961 consecutive gastroscopy patients at the University Teaching Hospital, Butare, over 12 months. Patient characteristics, endoscopic diagnoses and H. pylori status (by modified rapid urease testing) were analysed. The overall H. pylori positivity rate was 75% (n=825), similar to that found elsewhere in sub-Saharan Africa. Common endoscopic diagnoses included duodenal ulceration (20%), duodenitis (9%), benign gastric outlet obstruction (6%) and malignancy (5%). Duodenal ulceration was strongly associated with H. pylori infection (OR 6.2 [3.1-12.6]; p<0.001).

  6. The minimally invasive endoscopic management of septated chronic subdural hematomas: surgical technique.

    PubMed

    Berhouma, M; Jacquesson, T; Jouanneau, E

    2014-12-01

    Fibrin membranes and compartmentalization within the subdural space are a frequent cause of failure in the treatment of chronic subdural hematomas (CSH). This specific subtype of CSH classically requires craniotomy, which carries significant morbidity and mortality rates, particularly in elderly patients. In this work, we describe a minimally invasive endoscopic alternative. Under local scalp anesthesia, a rigid endoscope is inserted through a parietal burr hole in the subdural space to collapse fibrin septa and cut the internal membrane. It also allows cauterization of active bleedings and the placement of a drain under direct visualization. The endoscopic treatment of septated CSH represents a minimally invasive alternative to craniotomy especially for the internal membranectomy.

  7. Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.

    PubMed

    Bauder, Markus; Schmidt, Arthur; Caca, Karel

    2016-04-01

    Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. [Endoscopic assistance in surgery of cerebellopontine angle tumors].

    PubMed

    Poshataev, V K; Shimansky, V N; Tanyashin, S V; Karnaukhov, V V

    2014-01-01

    During the period of 2010-2012, 33 patients with cerebellopontine angle tumors were operated on at the Burdenko Neurosurgical Institute (Moscow, Russia) using different types of endoscopic assistance. All patients were operated on via the retrosigmoid suboccipital approach in semi-sitting and prone positions. 30° and 70° endoscopes were used during the surgery. Endoscopic assistance allowed us to increase the completeness of tumor removal and to reduce the risk of postoperative complications by retaining the anatomic integrity of cranial nerves and vascular structures in the base of the posterior cranial fossa. These benefits made it possible to maintain and improve quality of life in patients with CPA tumors in the postoperative period.

  9. Submucosal lipoma of the sigmoid colon as a rare cause of mucoid diarrhea: a case report.

    PubMed

    Dassanayake, S U B; Dinamithra, N P; Nawarathne, N M M

    2016-01-20

    Symptomatic presentations of colonic lipomas are very rare in clinical practice, and may mimic colonic malignancy. The likelihood of presenting symptoms has been shown to depend on the size of the lesion. We describe the case of a 72-year-old Sinhalese man presenting with worsening mucoid diarrhea who was subsequently diagnosed to have a lipoma of the sigmoid colon. His disease was successfully managed with endoscopic resection. Confidently establishing the rare diagnosis of a colonic lipoma usually requires a combination of endoscopic, radiological, and histological evaluation, and is therefore very challenging. With the advancement of endoscopic procedures, endoscopic resection is widely practiced as the definitive management of these cases.

  10. Endoscopic colloid cyst excision: surgical techniques and nuances.

    PubMed

    Azab, Waleed Abdelfattah; Najibullah, Mustafa; Yosef, Waleed

    2017-06-01

    Endoscopic excision of colloid cysts is currently well established as a minimally invasive and highly effective technique that is associated with less morbidity in comparison to microsurgical resection. Operative charts and videos of patients undergoing endoscopic colloid cyst excision were retrieved from the senior author's database of endoscopic procedures and reviewed. This revealed nine trans-foraminal and three trans-septal procedures. Description of the surgical techniques was then formulated. Variation of the technique is based on the specific patho-anatomical features of the colloid cyst being resected. For the trans-foraminal approach, we think that the rotational technique is associated with a more complete removal of the cyst wall and consequently lower recurrence rate.

  11. [Review of the active locomotion system for capsule endoscope].

    PubMed

    Zhao, Dechun; Guo, Yijun; Peng, Chenglin

    2010-02-01

    This review summarized the progress of researches on the active locomotion system for capsule endoscope, analyzed the moving and controlling principles in different locomotion systems, and compared their merits and shortcomings. Owing to the complexity of human intestines and the limits to the size and consumption of locomotion system from the capsule endoscope, there is not yet one kind of active locomotion system currently used in clinical practice. The locomotive system driven by an outer rotational magnetic field could improve the commercial endoscope capsule, while its magnetic field controlling moving is complex. Active locomotion system driven by shape memory alloys will be the orientated development and the point of research in the future.

  12. Endoscopic stent therapy in patients with chronic pancreatitis: a 5-year follow-up study.

    PubMed

    Weber, Andreas; Schneider, Jochen; Neu, Bruno; Meining, Alexander; Born, Peter; von Delius, Stefan; Bajbouj, Monther; Schmid, Roland M; Algül, Hana; Prinz, Christian

    2013-02-07

    This study analyzed clinical long-term outcomes after endoscopic therapy, including the incidence and treatment of relapse. This study included 19 consecutive patients (12 male, 7 female, median age 54 years) with obstructive chronic pancreatitis who were admitted to the 2(nd) Medical Department of the Technical University of Munich. All patients presented severe chronic pancreatitis (stage III°) according to the Cambridge classification. The majority of the patients suffered intermittent pain attacks. 6 of 19 patients had strictures of the pancreatic duct; 13 of 19 patients had strictures and stones. The first endoscopic retrograde pancreatography (ERP) included an endoscopic sphincterotomy, dilatation of the pancreatic duct, and stent placement. The first control ERP was performed 4 wk after the initial intervention, and the subsequent control ERP was performed after 3 mo to re-evaluate the clinical and morphological conditions. Clinical follow-up was performed annually to document the course of pain and the management of relapse. The course of pain was assessed by a pain scale from 0 to 10. The date and choice of the therapeutic procedure were documented in case of relapse. Initial endoscopic intervention was successfully completed in 17 of 19 patients. All 17 patients reported partial or complete pain relief after endoscopic intervention. Endoscopic therapy failed in 2 patients. Both patients were excluded from further analysis. One failed patient underwent surgery, and the other patient was treated conservatively with pain medication. Seventeen of 19 patients were followed after the successful completion of endoscopic stent therapy. Three of 17 patients were lost to follow-up. One patient was not available for interviews after the 1(st) year of follow-up. Two patients died during the 3(rd) year of follow-up. In both patients chronic pancreatitis was excluded as the cause of death. One patient died of myocardial infarction, and one patient succumbed to pneumonia. All three patients were excluded from follow-up analysis. Follow-up was successfully completed in 14 of 17 patients. 4 patients at time point 3, 2 patients at time point 4, 3 patients at time point 5 and 2 patients at time point 6 and time point 7 used continuous pain medication after endoscopic therapy. No relapse occurred in 57% (8/14) of patients. All 8 patients exhibited significantly reduced or no pain complaints during the 5-year follow-up. Seven of 8 patients were completely pain free 5 years after endoscopic therapy. Only 1 patient reported continuous moderate pain. In contrast, 7 relapses occurred in 6 of the 14 patients. Two relapses were observed during the 1(st) year, 2 relapses occurred during the 2(nd) year, one relapse was observed during the 3(rd) year, one relapse occurred during the 4(th) year, and one relapse occurred during the 5(th) follow-up year. Four of these six patients received conservative treatment with endoscopic therapy or analgesics. Relapse was conservatively treated using repeated stent therapy in 2 patients. Analgesic treatment was successful in the other 2 patients. 57% of patients exhibited long-term benefits after endoscopic therapy. Therefore, endoscopic therapy should be the treatment of choice in patients being inoperable or refusing surgical treatment.

  13. A Comparison of Open and Endoscopic Repair of Full-Thickness Tears of the Gluteus Medius Tendon at a Minimum of 2 Years Follow-up

    PubMed Central

    Nawabi, Danyal H.; Wentzel, Catherine; Ranawat, Anil S.; Bedi, Asheesh; Kelly, Bryan T.

    2015-01-01

    Objectives: Historically, tears of the gluteus medius tendon were repaired via an open approach yielding excellent outcomes. With the advent of hip arthroscopy, endoscopic techniques have been developed to repair abductor tears which have shown favorable early outcomes. The open technique may still be preferred for large tears with retraction (>4cm), but there is a paucity of data comparing open and endoscopic approaches. The purpose of this study was to compare the outcomes of open and endoscopic repair of full-thickness tears of the gluteus medius tendon. We hypothesized that the outcomes of the two approaches would be similar but that the open technique would have shorter surgical times. Methods: Between March 2010 and June 2012, 1267 patients (1518 hips) undergoing a hip preservation procedure were prospectively entered into a registry. From this cohort, we identified 27 patients (30 hips) that had undergone repair of the gluteus medius tendon with a minimum of 2 years follow-up. Nine patients (9 hips) had an open repair and 18 patients (21 hips) had an endoscopic repair. Patient-reported outcome scores, including the Modified Harris Hip Score (mHHS), the Hip Outcome Score-Activity of Daily Living (HOS-ADL), and the Sport-specific Subscale (HOS-SSS) were obtained preoperatively and at 1, 2, and 3 years postoperatively. Surgery time was obtained using operating room records. The femoral neck shaft angle (FNSA) and lateral center-edge angle (LCEA) were measured on preoperative radiographs. Continuous and categorical variables were compared between endoscopic and open abductor repair patients using independent-samples t-tests and chi-square or Fisher's exact tests (as appropriate), respectively. Given the limited sample size, no adjusted or matched analyses were performed. Results: The mean age (±SD) of the open and endoscopic groups was 62.0 ± 9.9 years and 51.6 ± 13.6 years respectively (p=0.05). There were 6 females (67%) in the open group and 17 females (94%) in the endoscopic group (p=0.09). Seven hips (78%) in the open group had varus necks (FNSA30°) compared to 15 hips (54%) in the endoscopic group (p=0.93). At a mean follow-up of 38.1 months (range, 24-87 months), there were large (> 35 points) and significant improvements (p0.8). One patient (11.1%) in the open group had a poor clinical outcome compared to 2 patients (11.1%) in the endoscopic group that required revision abductor repairs at 5 and 24 months respectively. The mean surgical time was 98.7 ± 21.3 minutes in the open and 122.0 ± 26.8 minutes in the endoscopic group (p=0.003). Conclusion: This study demonstrates that an open gluteus medius tendon repair results in a significant improvement in clinical outcome, that is similar to the scores seen after endoscopic repair. Varus femoral necks and acetabular overcoverage are common features of hips with abductor tears and may be useful diagnostic aids. The surgical time for an open technique is significantly shorter than the endoscopic technique. We recommend an open technique where an intra-articular hip arthroscopy is not required, or in those patients with large and retracted tears.

  14. Endoscopic Management of Upper Urinary Tract Urothelial Carcinoma.

    PubMed

    Samson, Patrick; Smith, Arthur D; Hoenig, David; Okeke, Zeph

    2018-05-01

    Endoscopic management of upper tract urothelial carcinoma has become more popular over the last few decades as there has been an impetus for renal preservation in these patients. While radical nephroureterectomy has been the gold standard in treatment of this disease, ureteroscopic and percutaneous management has become a viable option for select patients. The literature on endoscopic management of upper urinary tract tumors was explored. Different management methods are discussed, both from published literature and experience of the authors of this chapter. We review the indications, details of the procedure, and troubleshooting methods in the endoscopic management of upper tract urothelial carcinoma. Imperative indications as well as controversial indications are discussed. The role and efficacy of adjuvant intrarenal topical agents are examined as well as the protocol for administering these agents. Follow-up protocols are also reviewed. In select patients, endoscopic management with ureteroscopy and/or percutaneous resection of upper tract urothelial tumors is appropriate and can preserve renal function while obtaining comparable oncologic control compared with radical surgery.

  15. Multimedia article: Transvaginal laparoscopic cholecystectomy: laparoscopically assisted.

    PubMed

    Bessler, Marc; Stevens, Peter D; Milone, Luca; Hogle, Nancy J; Durak, Evren; Fowler, Dennis

    2008-07-01

    Natural orifice transluminal endoscopic surgery (NOTES) is considered the new frontier for minimally invasive surgery. NOTES procedures such as peritoneoscopy, splenectomy, and cholecystectomy in animal models have been described. The aim of our experiment was to determine the feasibility and technical aspects of a new endoluminal surgical procedure. After approval from Columbia's IACUC, a transvaginal laparoscopically assisted endoscopic cholecystectomy was performed on four 30 kg Yorkshire pigs. The first step was to insert a 1.5 cm endoscope into the vagina under direct laparoscopic vision. Then the gallbladder was reached and, with the help of a laparoscopic grasper to hold up the gallbladder, the operation was performed. At the end of the procedure the gallbladder was snared out through the vagina attached to the endoscope. There were no intraoperative complications such as bleeding, common bile duct or endo-abdominal organ damage. Total operative time ranged between 110 and 155 min. Based on our experience in the porcine model, we believe that a transvaginal endoscopic cholecystectomy is feasible in humans.

  16. Technical feasibility of patient-friendly screening and treatment of digestive disease by remote control robotic capsule endoscopes via the internet.

    PubMed

    Ohta, Hidetoshi; Kawashima, Makoto

    2014-01-01

    A few types of steerable capsule endoscopes have been proposed but disappointingly their systems were not applicable to common endoscopic treatment or pathological diagnosis. This study validates the possibility of treatment and biopsy by using an internet-linked (wireless control via the internet) robotic capsule endoscope (iRoboCap). iRoboCap consisted of three parts: an imaging unit, a movement control unit and a therapeutic tool unit. Two types of iRoboCaps were designed, one was a submarine type (iRoboCap-S) and the other was an amphibious type (iRoboCap-A). They were remotely and wirelessly steered by a portable tablet device using Bluetooth and via the internet. The success rates of biopsy or clipping were evaluated in a phantom. Although the two prototypes have various problems that need improving, we hope that our robotic and wireless innovations have opened the door to new endoscopic procedures and will pioneer various new applications in medicine.

  17. Integrated pressure and temperature sensor with high immunity against external disturbance for flexible endoscope operation

    NASA Astrophysics Data System (ADS)

    Maeda, Yusaku; Maeda, Kohei; Kobara, Hideki; Mori, Hirohito; Takao, Hidekuni

    2017-04-01

    In this study, an integrated pressure and temperature sensor device for a flexible endoscope with long-term stability in in vivo environments was developed and demonstrated. The sensor, which is embedded in the thin wall of the disposable endoscope hood, is intended for use in endoscopic surgery. The device surface is coated with a Cr layer to prevent photoelectronic generation induced by the strong light of the endoscope. The integrated temperature sensor allows compensation for the effect of the temperature drift on a pressure signal. The fabricated device pressure resolution is 0.4 mmHg; the corresponding pressure error is 3.2 mmHg. The packaged device was used in a surgical simulation in an animal experiment. Pressure and temperature monitoring was achieved even in a pH 1 acid solution. The device enables intraluminal pressure and temperature measurements of the stomach, which facilitate the maintenance of internal stomach conditions. The applicability of the sensor was successfully demonstrated in animal experiments.

  18. A Rare Case of Pancreas Divisum Accompanied by Acute Pancreatitis Following Endoscopic Hemostasis for Duodenal Ulcer Bleeding.

    PubMed

    Choi, Yong Hyeok; Yoon, Soon Man; Kim, Eun Bee; Oh, Youngmin; Kim, Keunmo; Lee, Jisun; Park, Seon Mee; Youn, Sei Jin

    2017-04-25

    Peptic ulcer bleeding is treated using endoscopic hemostasis using clips or bands. Pancreas divisum (PD), a congenital anomaly of the pancreas, usually has no clinical symptoms; however, pancreatitis may occur if there are disturbances in the drainage of pancreatic secretions. We report an unusual case of PD accompanied by acute pancreatitis, following endoscopic band ligation for duodenal ulcer bleeding. A 48-year-old woman was admitted to our hospital due to melena. An upper endoscopy revealed a small ulcer with oozing adjacent minor papilla. An endoscopic band ligation was performed on this lesion. Acute pancreatitis developed suddenly 6 hours after the band ligation and improved dramatically after removal of the band. Magnetic resonance cholangiopancreatography was performed, revealing complete PD. Endoscopic band ligation is known as the effective method for peptic ulcer bleeding; however, it should be used carefully in duodenal ulcer bleeding near the minor duodenal papilla due to the possibility of PD.

  19. Optical design of an optical coherence tomography and multispectral fluorescence imaging endoscope to detect early stage ovarian cancer

    NASA Astrophysics Data System (ADS)

    Tate, Tyler; Keenan, Molly; Swan, Elizabeth; Black, John; Utzinger, Urs; Barton, Jennifer

    2014-12-01

    The five year survival rate for ovarian cancer is over 90% if early detection occurs, yet no effective early screening method exists. We have designed and are constructing a dual modality Optical Coherence Tomography (OCT) and Multispectral Fluorescence Imaging (MFI) endoscope to optically screen the Fallopian tube and ovary for early stage cancer. The endoscope reaches the ovary via the natural pathway of the vagina, cervix, uterus and Fallopian tube. In order to navigate the Fallopian tube the endoscope must have an outer diameter of 600 μm, be highly flexible, steerable, tracking and nonperforating. The imaging systems consists of six optical subsystems, two from OCT and four from MFI. The optical subsystems have independent and interrelated design criteria. The endoscope will be tested on realistic tissue models and ex vivo tissue to prove feasibility of future human trials. Ultimately the project aims to provide women the first effective ovarian cancer screening technique.

  20. Advanced shape tracking to improve flexible endoscopic diagnostics

    NASA Astrophysics Data System (ADS)

    Cao, Caroline G. L.; Wong, Peter Y.; Lilge, Lothar; Gavalis, Robb M.; Xing, Hua; Zamarripa, Nate

    2008-03-01

    Colonoscopy is the gold standard for screening for inflammatory bowel disease and colorectal cancer. Flexible endoscopes are difficult to manipulate, especially in the distensible and tortuous colon, sometimes leading to disorientation during the procedure and missed diagnosis of lesions. Our goal is to design a navigational aid to guide colonoscopies, presenting a three dimensional representation of the endoscope in real-time. Therefore, a flexible sensor that can track the position and shape of the entire length of the endoscope is needed. We describe a novel shape-tracking technology utilizing a single modified optical fiber. By embedding fluorophores in the buffer of the fiber, we demonstrated a relationship between fluorescence intensity and fiber curvature. As much as a 40% increase in fluorescence intensity was achieved when the fiber's local bend radius decreased from 58 mm to 11 mm. This approach allows for the construction of a three-dimensional shape tracker that is small enough to be easily inserted into the biopsy channel of current endoscopes.

  1. Medial maxillectomy in recalcitrant sinusitis: when, why and how?

    PubMed

    Konstantinidis, Iordanis; Constantinidis, Jannis

    2014-02-01

    We reviewed all journal articles relevant to endoscopic medial maxillectomy in patients with recalcitrant chronic maxillary sinusitis in order to present all indications, the underlying pathophysiology and the developed surgical techniques. Despite the high success rate of middle meatal antrostomy, cases with persistent maxillary sinus disease exist and often need a more extended endoscopic procedure for the better control of the disease. Such surgical option uses gravity for better sinus drainage and offers better saline irrigation, local application of medications and follow-up inspection. An endoscopic medial maxillectomy and its modified forms offer a wider surgical field and access to all 'difficult' areas of the maxillary sinus. Patients with previous limited endoscopic sinus surgery or extended open surgery, cystic fibrosis, extensive mucoceles, allergic fungal sinusitis, odontogenic infections, foreign bodies and so on may suffer from recurrent disease requiring an endoscopic medial maxillectomy. Depending on the disease, various modifications of the procedure can be performed preserving the anterior buttress, nasolacrimal duct and inferior turbinate if possible.

  2. Modified endoscopic medial maxillectomy for zygomatic implant salvage

    PubMed Central

    Tajudeen, Bobby A.; Adappa, Nithin D.; Palmer, James N.

    2016-01-01

    Objectives: Odontogenic chronic rhinosinusitis (CRS) is an epidemiologically important disease process due, in part, to the increasingly commonplace use of dental restorative procedures such as zygomatic implantation. Traditional management of this clinical entity typically entails extraction of the infected hardware via an open or endoscopic approach. We describe a novel management strategy of odontogenic CRS following bilateral zygomatic implantation for oral rehabilitation that we surgically salvaged via a modified endoscopic medial maxillectomy. Methods: We describe the presentation and management of a case of metachronous development of bilateral CRS subsequent to zygomatic implantation. Results: The patient's postoperative course was characterized by marked endoscopic, radiologic, and symptomatic improvement as measured by the 22-item Sino-Nasal Outcome Test. Conclusion: We describe a novel treatment strategy for the management of odontogenic sinusitis resulting from erroneous zygomatic implant placement. Modified endoscopic medial maxillectomy in this clinical context facilitates mucosal normalization of the affected sinus, while permitting preservation of oral function through salvage of the displaced implant. PMID:28107147

  3. Leopard Skin-Like Colonic Mucosa: A Novel Endoscopic Finding of Chronic Granulomatous Disease-Associated Colitis.

    PubMed

    Obayashi, Naho; Arai, Katsuhiro; Nakano, Natsuko; Mizukami, Tomoyuki; Kawai, Toshinao; Yamamoto, Shojiro; Shimizu, Hirotaka; Nunoi, Hiroyuki; Shimizu, Toshiaki; Tang, Julian; Onodera, Masafumi

    2016-01-01

    Chronic granulomatous disease (CGD) is a rare inherited disorder in which phagocytes are unable to eradicate pathogens because of a deficit of nicotinamide adenine dinucleotide phosphate oxidase. Among CGD patients, ∼ 30% to 50% develop severe gastrointestinal tract symptoms. Although characteristic histologic findings of CGD-associated colitis have been reported, information on endoscopic features remained vague. A total of 8 male patients with CGD (ages 2-23 years) from 2 Japanese institutions underwent colonoscopy for the evaluation of their fever, diarrhea, bloody stool, and abdominal pain. The endoscopic and histologic findings were retrospectively reviewed. The endoscopic findings of CGD-associated colitis appeared varied. Notably, brownish dots over a yellowish edematous mucosa were observed in 3 of the 8 patients. Prominent pigment-laden macrophages were noted histologically on the mucosa. Although nonspecific endoscopic findings of CGD-associated colitis have been reported before, our observation of brownish dots spread across a yellowish edematous mucosa, termed "leopard sign," could be a unique feature of this condition.

  4. A systematic review and quantitative analysis of different therapies for pancreas divisum.

    PubMed

    Hafezi, Mohammadreza; Mayschak, Bartosch; Probst, Pascal; Büchler, Markus W; Hackert, Thilo; Mehrabi, Arianeb

    2017-09-01

    Pancreas divisum is the most common anatomical variation of pancreatic ductal system affecting 5-10% of population. Therapy includes different endoscopic and surgical procedures. The aim of this article was to summarize actual evidence of different treatment. A Medline search was performed to identify all studies, investigating endoscopic or surgical therapy of Pancreas divisum. An individual data simulation model was applied to compare endoscopic and surgical studies. 56 observational studies (31 endoscopic and 25 surgical studies) were included in analyses. Surgery was significantly superior to endoscopic treatment in terms of success rate (72% vs. 62.3), complication rate (23.8% vs. 31.3%) and re-intervention rate (14.4% vs. 28.3%). Surgery may be superior to endoscopy in terms of treatment success and complications. There is no study comparing these two therapies. Consequently, a randomized trial is needed to clarify if endoscopy or surgery is superior in the therapy of pancreas divisum. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Treatment Using the SpyGlass Digital System in a Patient with Hepatolithiasis after a Whipple Procedure.

    PubMed

    Harima, Hirofumi; Hamabe, Kouichi; Hisano, Fusako; Matsuzaki, Yuko; Itoh, Tadahiko; Sanuki, Kazutoshi; Sakaida, Isao

    2018-05-23

    An 89-year-old man was referred to our hospital for treatment of hepatolithiasis causing recurrent cholangitis. He had undergone a prior Whipple procedure. Computed tomography demonstrated left-sided hepatolithiasis. First, we conducted peroral direct cholangioscopy (PDCS) using an ultraslim endoscope. Although PDCS was successfully conducted, it was unsuccessful in removing all the stones. The stones located in the B2 segment were difficult to remove because the endoscope could not be inserted deeply into this segment due to the small size of the intrahepatic bile duct. Next, we substituted the endoscope with an upper gastrointestinal endoscope. After positioning the endoscope, the SpyGlass digital system (SPY-DS) was successfully inserted deep into the B2 segment. Upon visualizing the residual stones, we conducted SPY-DS-guided electrohydraulic lithotripsy. The stones were disintegrated and completely removed. In cases of PDCS failure, a treatment strategy using the SPY-DS can be considered for patients with hepatolithiasis after a Whipple procedure.

  6. Importance of histological evaluation in endoscopic resection of early colorectal cancer

    PubMed Central

    Yoshida, Naohisa; Naito, Yuji; Yagi, Nobuaki; Yanagisawa, Akio

    2012-01-01

    The diagnostic criteria for colonic intraepithelial tumors vary from country to country. While intramucosal adenocarcinoma is recognized in Japan, in Western countries adenocarcinoma is diagnosed only if the tumor invades to the submucosa and accesses the muscularis mucosae. However, endoscopic therapy, including endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD), is used worldwide to treat adenoma and early colorectal cancer. Precise histopathological evaluation is important for the curativeness of these therapies as inappropriate endoscopic therapy causes local recurrence of the tumor that may develop into fatal metastasis. Therefore, colorectal ESD and EMR are not indicated for cancers with massive submucosal invasion. However, diagnosis of cancer with massive submucosal invasion by endoscopy is limited, even when magnifying endoscopy for pit pattern and narrow band imaging and flexible spectral imaging color of enhancement are performed. Therefore, occasional cancers with massive submucosal invasion will be treated by ESD and EMR. Precise histopathological evaluation of these lesions should be performed in order to determine the necessity of additional therapy, including surgical resection. PMID:22532932

  7. The role of mitomycin C in surgery of the frontonasal recess: a prospective open pilot study.

    PubMed

    Amonoo-Kuofi, Kwame; Lund, Valerie J; Andrews, Peter; Howard, David J

    2006-01-01

    Mitomycin C (MMC) inhibits fibroblast proliferation. The objective of this study was to determine the efficacy of MMC in reducing frontal ostium stenosis after endoscopic sinus surgery. A prospective open pilot study was conducted in 28 patients who had undergone one or more previous surgical interventions for frontal sinusitis. MMC solution was applied to the frontal ostial region via an endoscopic or combined endoscopic and external approach. Patency of the frontal ostium was evaluated endoscopically during regular follow-up. If restenosis was observed further, endoscopic application of MMC was undertaken. There were 17 men and 11 women (mean age, 51.7 years; range, 26-86 years). Mean number of applications was 1.5 (range, 1:3). Mean follow-up was 19 months (range, 6-32 months). Patency rate was 86%. Mitomycin appears to have an important role in reducing postoperative scarring, which may obviate the need for repeated and more extensive surgery.

  8. Endoscopic management of intrabiliary-ruptured hepatic hydatid cyst.

    PubMed

    Singh, Virendra; Reddy, Deevaguntla Chandrasekhar; Verma, Ganga Ram; Singh, Gurpreet

    2006-06-01

    Intrabiliary rupture of hepatic hydatid cyst causes serious morbidity and mortality. These patients are usually managed surgically. We evaluated the feasibility and outcome of an alternative method of treatment of these patients. Seven patients with ruptured hepatic hydatid into the biliary tract underwent endoscopic treatment consisting of endoscopic sphincterotomy, cyst material extraction and hypertonic saline lavage via nasocystic catheter. Median age of patients was 40 years (range 17-50 years) with a male:female ratio of 2:5. Abdominal pain, jaundice and fever were seen in all patients. Six out of seven patients were positive for hydatid serology. All patients were successfully treated by endoscopic sphincterotomy, clearance of cyst material and hypertonic saline lavage. On a follow-up of 6 months to 4 years (median, 3.5 years), ultrasonography, computed tomography of the abdomen and magnetic resonance imaging of the abdomen showed a complete cure. There were no complications related to procedure. This study demonstrates endoscopic treatment as one of the therapeutic options of ruptured hepatic hydatid cyst into the biliary tract.

  9. The role of liquid simethicone in enhancing endoscopic visibility prior to esophagogastroduodenoscopy (EGD): A prospective, randomized, double-blinded, placebo-controlled trial.

    PubMed

    Keeratichananont, Suriya; Sobhonslidsuk, Abhasnee; Kitiyakara, Taya; Achalanan, Narin; Soonthornpun, Supamai

    2010-08-01

    Simethicone improves endoscopic visibility and diagnostic accuracy during colonoscopy and capsule endoscopy. Nevertheless, there have been limited data on its usefulness in esophagogastroduodenoscopy (EGD). To evaluate the effectiveness of simethicone on enhancing endoscopic visibility in patients undergoing EGD. 121 patients were randomized to take 2 ml ofeither liquid simethicone or placebo in 60 ml of water at 15-30 minutes before EGD. The severity scores of foam and bubbles at the esophagus, stomach and duodenum were compared. Simethicone improved endoscopic visibility by diminishing mean cumulative (6.83 +/- 2.4 vs. 11.05 +/- 2.6, p < 0.001) and local scores offoam and bubbles at all areas, and decreased the number and timing ofadjunctive simethicone washing (17.5% vs. 74.1%, p < 0.001 and 0 vs. 19 seconds, p < 0.001). Simethicone increased endoscopist and patient satisfaction significantly without having adverse effects. Using simethicone before EGD enhances endoscopic visibility, reduces adjunctive simethicone washing and increases endoscopist and patient satisfaction.

  10. Endoscopic endonasal transsphenoidal surgery: implementation of an operative and perioperative checklist.

    PubMed

    Christian, Eisha; Harris, Brianna; Wrobel, Bozena; Zada, Gabriel

    2014-01-01

    Endoscopic endonasal surgery relies heavily on specialized operative instrumentation and optimization of endocrinological and other critical adjunctive intraoperative factors. Several studies and worldwide initiatives have previously established that intraoperative and perioperative surgical checklists can minimize the incidence of and prevent adverse events. The aim of this article was to outline some of the most common considerations in the perioperative and intraoperative preparation for endoscopic endonasal transsphenoidal surgery. The authors implemented and prospectively evaluated a customized checklist at their institution in 25 endoscopic endonasal operations for a variety of sellar and skull base pathological entities. Although no major errors were detected, near misses pertaining primarily to missing components of surgical equipment or instruments were identified in 9 cases (36%). The considerations in the checklist provided in this article can serve as a basic template for further customization by centers performing endoscopic endonasal surgery, where their application may reduce the incidence of adverse or preventable errors associated with surgical treatment of sellar and skull base lesions.

  11. Design of an autofocus capsule endoscope system and the corresponding 3D reconstruction algorithm.

    PubMed

    Zhang, Wei; Jin, Yi-Tao; Guo, Xin; Su, Jin-Hui; You, Su-Ping

    2016-10-01

    A traditional capsule endoscope can only take 2D images, and most of the images are not clear enough to be used for diagnosing. A 3D capsule endoscope can help doctors make a quicker and more accurate diagnosis. However, blurred images negatively affect reconstruction accuracy. A compact, autofocus capsule endoscope system is designed in this study. Using a liquid lens, the system can be electronically controlled to autofocus, and without any moving elements. The depth of field of the system is in the 3-100 mm range and its field of view is about 110°. The images captured by this optical system are much clearer than those taken by a traditional capsule endoscope. A 3D reconstruction algorithm is presented to adapt to the zooming function of our proposed system. Simulations and experiments have shown that more feature points can be correctly matched and a higher reconstruction accuracy can be achieved by this strategy.

  12. Experimental assessment of a 3-D plenoptic endoscopic imaging system.

    PubMed

    Le, Hanh N D; Decker, Ryan; Krieger, Axel; Kang, Jin U

    2017-01-01

    An endoscopic imaging system using a plenoptic technique to reconstruct 3-D information is demonstrated and analyzed in this Letter. The proposed setup integrates a clinical surgical endoscope with a plenoptic camera to achieve a depth accuracy error of about 1 mm and a precision error of about 2 mm, within a 25 mm × 25 mm field of view, operating at 11 frames per second.

  13. Experimental assessment of a 3-D plenoptic endoscopic imaging system

    PubMed Central

    Le, Hanh N. D.; Decker, Ryan; Krieger, Axel; Kang, Jin U.

    2017-01-01

    An endoscopic imaging system using a plenoptic technique to reconstruct 3-D information is demonstrated and analyzed in this Letter. The proposed setup integrates a clinical surgical endoscope with a plenoptic camera to achieve a depth accuracy error of about 1 mm and a precision error of about 2 mm, within a 25 mm × 25 mm field of view, operating at 11 frames per second. PMID:29449863

  14. Refractory Gastrointestinal Bleeding: Role of Angiographic Intervention

    PubMed Central

    2013-01-01

    Although endoscopic hemostasis remains initial treatment modality for nonvariceal gastrointestinal (GI) bleeding, severe bleeding despite endoscopic management occurs in 5% to 10% of the patients, requiring surgery or transcatheter arterial embolization (TAE). TAE is now considered the first-line therapy for massive GI bleeding refractory to endoscopic management. GI endoscopists need to be familiar with indications, principles, outcomes, and complications of TAE, as well as embolic materials available. PMID:24143308

  15. Endoscopic endonasal approach for mass resection of the pterygopalatine fossa

    PubMed Central

    Plzák, Jan; Kratochvil, Vít; Kešner, Adam; Šurda, Pavol; Vlasák, Aleš; Zvěřina, Eduard

    2017-01-01

    OBJECTIVES: Access to the pterygopalatine fossa is very difficult due to its complex anatomy. Therefore, an open approach is traditionally used, but morbidity is unavoidable. To overcome this problem, an endoscopic endonasal approach was developed as a minimally invasive procedure. The surgical aim of the present study was to evaluate the utility of the endoscopic endonasal approach for the management of both benign and malignant tumors of the pterygopalatine fossa. METHOD: We report our experience with the endoscopic endonasal approach for the management of both benign and malignant tumors and summarize recent recommendations. A total of 13 patients underwent surgery via the endoscopic endonasal approach for pterygopalatine fossa masses from 2014 to 2016. This case group consisted of 12 benign tumors (10 juvenile nasopharyngeal angiofibromas and two schwannomas) and one malignant tumor. RESULTS: No recurrent tumor developed during the follow-up period. One residual tumor (juvenile nasopharyngeal angiofibroma) that remained in the cavernous sinus was stable. There were no significant complications. Typical sequelae included hypesthesia of the maxillary nerve, trismus, and dry eye syndrome. CONCLUSION: The low frequency of complications together with the high efficacy of resection support the use of the endoscopic endonasal approach as a feasible, safe, and beneficial technique for the management of masses in the pterygopalatine fossa. PMID:29069259

  16. Endoscopic Radiofrequency Ablation-Assisted Resection of Juvenile Nasopharyngeal Angiofibroma: Comparison with Traditional Endoscopic Technique.

    PubMed

    McLaughlin, Eamon J; Cunningham, Michael J; Kazahaya, Ken; Hsing, Julianna; Kawai, Kosuke; Adil, Eelam A

    2016-06-01

    To evaluate the feasibility of radiofrequency surgical instrumentation for endoscopic resection of juvenile nasopharyngeal angiofibroma (JNA) and to test the hypothesis that endoscopic radiofrequency ablation-assisted (RFA) resection will have superior intraoperative and/or postoperative outcomes as compared with traditional endoscopic (TE) resection techniques. Case series with chart review. Two tertiary care pediatric hospitals. Twenty-nine pediatric patients who underwent endoscopic transnasal resection of JNA from January 2000 to December 2014. Twenty-nine patients underwent RFA (n = 13) or TE (n = 16) JNA resection over the 15-year study period. Mean patient age was not statistically different between the 2 groups (P = .41); neither was their University of Pittsburgh Medical Center classification stage (P = .79). All patients underwent preoperative embolization. Mean operative times were not statistically different (P = .29). Mean intraoperative blood loss and the need for a transfusion were also not statistically different (P = .27 and .47, respectively). Length of hospital stay was not statistically different (P = .46). Recurrence rates did not differ between groups (P = .99) over a mean follow-up period of 2.3 years. There were no significant differences between RFA and TE resection in intraoperative or postoperative outcome parameters. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  17. "Puestow modified procedure in the era of advanced endoscopic interventions for the management of chronic lithiasic pancreatitis. A two cases report".

    PubMed

    Fragulidis, Georgios P; Vezakis, Αntonios; Dellaportas, Dionissios; Sotirova, Ira; Koutoulidis, Vassilis; Kontis, Elliseos; Polydorou, Andreas

    2015-01-01

    Pancreatic duct calculi in chronic pancreatitis (CP) patients are the main cause of intractable pain which is their main symptom. Decompression options of for the main pancreatic duct are both surgical and advanced endoscopic procedures. A 64-year-old male with known CP due to alcohol consumption and a 36-year-old female with known idiopathic CP and pancreatic duct calculi were managed recently in our hospital where endoscopic procedures were unsuccessful. A surgical therapy was considered and a longitudinal pancreaticojejunostomy (modified Puestow procedure) in both patients was performed with excellent results. Over the last 30 years, endoscopic procedures are developed to manage pancreatic duct strictures and calculi of the main pancreatic duct in CP patients. In both of our cases endoscopic therapy was first attempted but failed to extract the pancreatic duct stones, due to their size and speculations. Modified Puestow procedure was performed for both and it was successful for long term pain relief. Despite advancement in endoscopic interventions and less invasive therapies for the management of chronic lithiasic pancreatitis we consider that classic surgical management can be appropriate in certain cases. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Endoscopic nasopharyngeal exploration at the end of conventional curettage adenoidectomy.

    PubMed

    Abdel-Aziz, Mosaad

    2012-03-01

    Adenoid hypertrophy (AH) is a common cause of airway obstruction in children and its recurrence after conventional curettage adenoidectomy is not rare. The purpose of this study is to assess the efficacy of endoscopic nasopharyngeal exploration at the end of curettage adenoidectomy on decreasing the incidence of adenoid re-hypertrophy. Three hundred and fifty children diagnosed as having AH, underwent conventional curettage adenoidectomy by a single surgeon. The cases were randomly divided into two equal groups A and B, group B were further subjected to nasopharyngeal exploration by the nasal endoscope after removal of their adenoids with cauterization of any visible residuals, while group A were not subjected to this endoscopic maneuver. Follow-up was carried out for at least 2 years; flexible nasopharyngoscopy was used for detection of recurrent AH. Cases that were not subjected to endoscopic nasopharyngeal exploration (group A) showed a high recurrence rate (6.6%), while explored cases (group B) showed a low incidence of recurrence (1.18%). Most recurrence of group A (6%) was detected within the first year of the follow-up period which may indicate re-growth of residual adenoidal tissues that were missed during conventional curettage adenoidectomy. Endoscopic nasopharyngeal exploration at the end of conventional curettage adenoidectomy is a useful method in decreasing the incidence of recurrent AH.

  19. Volume holographic reflection endoscope for in-vivo ovarian cancer clinical studies

    NASA Astrophysics Data System (ADS)

    Howlett, I. D.; Gordon, M.; Brownlee, J. W.; Barton, J. K.; Kostuk, R. K.

    2014-03-01

    We present the design for an endoscopic system capable of imaging tissues of the ovary at two selected imaging depths simultaneously. The method utilizes a multiplexed volume hologram to select wavefronts from different depths within the tissue. It is the first demonstration of an endoscopic volume holographic imaging system. The endoscope uses both gradient index (GRIN) optical components and off the shelf singlet lenses to relay an image from the distal tip to the proximal end. The endoscope has a minimum diameter of 3.75 mm. The system length is 30 cm which is connected to a handle that includes the holographic components and optics that relay the image to a camera. Preliminary evaluation of the endoscope was performed with tissue phantoms and calibrated targets, which shows lateral resolution ≍ 4 μm at an operating wavelength of 660 nm. The hologram is recorded in phenanthraquinone doped poly methacrylate and is designed to produce images from two tissue depths. One image is obtained at the tissue surface and the second 70 μm below the surface. This method requires no mechanical scanning and acquires an image at the camera frame rate. The preliminary ex-vivo results show good correlation with histology sections of the same tissue sections.

  20. Hybrid model based unified scheme for endoscopic Cerenkov and radio-luminescence tomography: Simulation demonstration

    NASA Astrophysics Data System (ADS)

    Wang, Lin; Cao, Xin; Ren, Qingyun; Chen, Xueli; He, Xiaowei

    2018-05-01

    Cerenkov luminescence imaging (CLI) is an imaging method that uses an optical imaging scheme to probe a radioactive tracer. Application of CLI with clinically approved radioactive tracers has opened an opportunity for translating optical imaging from preclinical to clinical applications. Such translation was further improved by developing an endoscopic CLI system. However, two-dimensional endoscopic imaging cannot identify accurate depth and obtain quantitative information. Here, we present an imaging scheme to retrieve the depth and quantitative information from endoscopic Cerenkov luminescence tomography, which can also be applied for endoscopic radio-luminescence tomography. In the scheme, we first constructed a physical model for image collection, and then a mathematical model for characterizing the luminescent light propagation from tracer to the endoscopic detector. The mathematical model is a hybrid light transport model combined with the 3rd order simplified spherical harmonics approximation, diffusion, and radiosity equations to warrant accuracy and speed. The mathematical model integrates finite element discretization, regularization, and primal-dual interior-point optimization to retrieve the depth and the quantitative information of the tracer. A heterogeneous-geometry-based numerical simulation was used to explore the feasibility of the unified scheme, which demonstrated that it can provide a satisfactory balance between imaging accuracy and computational burden.

Top