Sample records for endoscopic image-processing technology

  1. Towards standardized assessment of endoscope optical performance: geometric distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Desai, Viraj N.; Ngo, Ying Z.; Cheng, Wei-Chung; Pfefer, Joshua

    2013-12-01

    Technological advances in endoscopes, such as capsule, ultrathin and disposable devices, promise significant improvements in safety, clinical effectiveness and patient acceptance. Unfortunately, the industry lacks test methods for preclinical evaluation of key optical performance characteristics (OPCs) of endoscopic devices that are quantitative, objective and well-validated. As a result, it is difficult for researchers and developers to compare image quality and evaluate equivalence to, or improvement upon, prior technologies. While endoscope OPCs include resolution, field of view, and depth of field, among others, our focus in this paper is geometric image distortion. We reviewed specific test methods for distortion and then developed an objective, quantitative test method based on well-defined experimental and data processing steps to evaluate radial distortion in the full field of view of an endoscopic imaging system. Our measurements and analyses showed that a second-degree polynomial equation could well describe the radial distortion curve of a traditional endoscope. The distortion evaluation method was effective for correcting the image and can be used to explain other widely accepted evaluation methods such as picture height distortion. Development of consensus standards based on promising test methods for image quality assessment, such as the method studied here, will facilitate clinical implementation of innovative endoscopic devices.

  2. MEMS-based liquid lens for capsule endoscope

    NASA Astrophysics Data System (ADS)

    Seo, S. W.; Han, S.; Seo, J. H.; Kim, Y. M.; Kang, M. S.; Min, N. G.; Choi, W. B.; Sung, M. Y.

    2008-03-01

    The capsule endoscope, a new application area of digital imaging, is growing rapidly but needs the versatile imaging capabilities such as auto-focusing and zoom-in to be an active diagnostic tool. The liquid lens based on MEMS technology can be a strong candidate because it is able to be small enough. In this paper, a cylinder-type liquid lens was designed based on Young-Lippmann model and then fabricated with MEMS technology combining the silicon thin-film process and the wafer bonding process. The focal length of the lens module including the fabricated liquid lens was changed reproducibly as a function of the applied voltage. With the change of 30V in the applied bias, the focal length of the constructed lens module could be tuned in the range of about 42cm. The fabricated liquid lens was also proven to be small enough to be adopted in the capsule endoscope, which means the liquid lens can be utilized for the imaging capability improvement of the capsule endoscope.

  3. Development of the local magnification method for quantitative evaluation of endoscope geometric distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Cheng, Wei-Chung; Suresh, Nitin; Hua, Hong

    2016-05-01

    With improved diagnostic capabilities and complex optical designs, endoscopic technologies are advancing. As one of the several important optical performance characteristics, geometric distortion can negatively affect size estimation and feature identification related diagnosis. Therefore, a quantitative and simple distortion evaluation method is imperative for both the endoscopic industry and the medical device regulatory agent. However, no such method is available yet. While the image correction techniques are rather mature, they heavily depend on computational power to process multidimensional image data based on complex mathematical model, i.e., difficult to understand. Some commonly used distortion evaluation methods, such as the picture height distortion (DPH) or radial distortion (DRAD), are either too simple to accurately describe the distortion or subject to the error of deriving a reference image. We developed the basic local magnification (ML) method to evaluate endoscope distortion. Based on the method, we also developed ways to calculate DPH and DRAD. The method overcomes the aforementioned limitations, has clear physical meaning in the whole field of view, and can facilitate lesion size estimation during diagnosis. Most importantly, the method can facilitate endoscopic technology to market and potentially be adopted in an international endoscope standard.

  4. Advanced endoscopic imaging: European Society of Gastrointestinal Endoscopy (ESGE) Technology Review.

    PubMed

    East, James E; Vleugels, Jasper L; Roelandt, Philip; Bhandari, Pradeep; Bisschops, Raf; Dekker, Evelien; Hassan, Cesare; Horgan, Gareth; Kiesslich, Ralf; Longcroft-Wheaton, Gaius; Wilson, Ana; Dumonceau, Jean-Marc

    2016-11-01

    Background and aim: This technical review is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the utilization of advanced endoscopic imaging in gastrointestinal (GI) endoscopy. Methods: This technical review is based on a systematic literature search to evaluate the evidence supporting the use of advanced endoscopic imaging throughout the GI tract. Technologies considered include narrowed-spectrum endoscopy (narrow band imaging [NBI]; flexible spectral imaging color enhancement [FICE]; i-Scan digital contrast [I-SCAN]), autofluorescence imaging (AFI), and confocal laser endomicroscopy (CLE). The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was adopted to define the strength of recommendation and the quality of evidence. Main recommendations: 1. We suggest advanced endoscopic imaging technologies improve mucosal visualization and enhance fine structural and microvascular detail. Expert endoscopic diagnosis may be improved by advanced imaging, but as yet in community-based practice no technology has been shown consistently to be diagnostically superior to current practice with high definition white light. (Low quality evidence.) 2. We recommend the use of validated classification systems to support the use of optical diagnosis with advanced endoscopic imaging in the upper and lower GI tracts (strong recommendation, moderate quality evidence). 3. We suggest that training improves performance in the use of advanced endoscopic imaging techniques and that it is a prerequisite for use in clinical practice. A learning curve exists and training alone does not guarantee sustained high performances in clinical practice. (Weak recommendation, low quality evidence.) Conclusion: Advanced endoscopic imaging can improve mucosal visualization and endoscopic diagnosis; however it requires training and the use of validated classification systems. © Georg Thieme Verlag KG Stuttgart · New York.

  5. MEMS scanning micromirror for optical coherence tomography.

    PubMed

    Strathman, Matthew; Liu, Yunbo; Keeler, Ethan G; Song, Mingli; Baran, Utku; Xi, Jiefeng; Sun, Ming-Ting; Wang, Ruikang; Li, Xingde; Lin, Lih Y

    2015-01-01

    This paper describes an endoscopic-inspired imaging system employing a micro-electromechanical system (MEMS) micromirror scanner to achieve beam scanning for optical coherence tomography (OCT) imaging. Miniaturization of a scanning mirror using MEMS technology can allow a fully functional imaging probe to be contained in a package sufficiently small for utilization in a working channel of a standard gastroesophageal endoscope. This work employs advanced image processing techniques to enhance the images acquired using the MEMS scanner to correct non-idealities in mirror performance. The experimental results demonstrate the effectiveness of the proposed technique.

  6. MEMS scanning micromirror for optical coherence tomography

    PubMed Central

    Strathman, Matthew; Liu, Yunbo; Keeler, Ethan G.; Song, Mingli; Baran, Utku; Xi, Jiefeng; Sun, Ming-Ting; Wang, Ruikang; Li, Xingde; Lin, Lih Y.

    2014-01-01

    This paper describes an endoscopic-inspired imaging system employing a micro-electromechanical system (MEMS) micromirror scanner to achieve beam scanning for optical coherence tomography (OCT) imaging. Miniaturization of a scanning mirror using MEMS technology can allow a fully functional imaging probe to be contained in a package sufficiently small for utilization in a working channel of a standard gastroesophageal endoscope. This work employs advanced image processing techniques to enhance the images acquired using the MEMS scanner to correct non-idealities in mirror performance. The experimental results demonstrate the effectiveness of the proposed technique. PMID:25657887

  7. Identification of early cancerous lesion of esophagus with endoscopic images by hyperspectral image technique (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Huang, Shih-Wei; Chen, Shih-Hua; Chen, Weichung; Wu, I.-Chen; Wu, Ming Tsang; Kuo, Chie-Tong; Wang, Hsiang-Chen

    2016-03-01

    This study presents a method to identify early esophageal cancer within endoscope using hyperspectral imaging technology. The research samples are three kinds of endoscopic images including white light endoscopic, chromoendoscopic, and narrow-band endoscopic images with different stages of pathological changes (normal, dysplasia, dysplasia - esophageal cancer, and esophageal cancer). Research is divided into two parts: first, we analysis the reflectance spectra of endoscopic images with different stages to know the spectral responses by pathological changes. Second, we identified early cancerous lesion of esophagus by principal component analysis (PCA) of the reflectance spectra of endoscopic images. The results of this study show that the identification of early cancerous lesion is possible achieve from three kinds of images. In which the spectral characteristics of NBI endoscopy images of a gray area than those without the existence of the problem the first two, and the trend is very clear. Therefore, if simply to reflect differences in the degree of spectral identification, chromoendoscopic images are suitable samples. The best identification of early esophageal cancer is using the NBI endoscopic images. Based on the results, the use of hyperspectral imaging technology in the early endoscopic esophageal cancer lesion image recognition helps clinicians quickly diagnose. We hope for the future to have a relatively large amount of endoscopic image by establishing a hyperspectral imaging database system developed in this study, so the clinician can take this repository more efficiently preliminary diagnosis.

  8. Towards automated visual flexible endoscope navigation.

    PubMed

    van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J

    2013-10-01

    The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.

  9. Endoscopes with latest technology and concept.

    PubMed

    Gotoh

    2003-09-01

    Endoscopic imaging systems that perform as the "eye" of the operator during endoscopic surgical procedures have developed rapidly due to various technological developments. In addition, since the most recent turn of the century robotic surgery has increased its scope through the utilization of systems such as Intuitive Surgical's da Vinci System. To optimize the imaging required for precise robotic surgery, a unique endoscope has been developed, consisting of both a two dimensional (2D) image optical system for wider observation of the entire surgical field, and a three dimensional (3D) image optical system for observation of the more precise details at the operative site. Additionally, a "near infrared radiation" endoscopic system is under development to detect the sentinel lymph node more readily. Such progress in the area of endoscopic imaging is expected to enhance the surgical procedure from both the patient's and the surgeon's point of view.

  10. Advanced endoscopic imaging in gastric neoplasia and preneoplasia

    PubMed Central

    Lee, Jonathan W J; Lim, Lee Guan; Yeoh, Khay Guan

    2017-01-01

    Conventional white light endoscopy remains the current standard in routine clinical practice for early detection of gastric cancer. However, it may not accurately diagnose preneoplastic gastric lesions. The technological advancements in the field of endoscopic imaging for gastric lesions are fast growing. This article reviews currently available advanced endoscopic imaging modalities, in particular chromoendoscopy, narrow band imaging and confocal laser endomicroscopy, and their corresponding evidence shown to improve diagnosis of preneoplastic gastric lesions. Raman spectrometry and polarimetry are also introduced as promising emerging technologies. PMID:28176895

  11. Design of embedded endoscopic ultrasonic imaging system

    NASA Astrophysics Data System (ADS)

    Li, Ming; Zhou, Hao; Wen, Shijie; Chen, Xiodong; Yu, Daoyin

    2008-12-01

    Endoscopic ultrasonic imaging system is an important component in the endoscopic ultrasonography system (EUS). Through the ultrasonic probe, the characteristics of the fault histology features of digestive organs is detected by EUS, and then received by the reception circuit which making up of amplifying, gain compensation, filtering and A/D converter circuit, in the form of ultrasonic echo. Endoscopic ultrasonic imaging system is the back-end processing system of the EUS, with the function of receiving digital ultrasonic echo modulated by the digestive tract wall from the reception circuit, acquiring and showing the fault histology features in the form of image and characteristic data after digital signal processing, such as demodulation, etc. Traditional endoscopic ultrasonic imaging systems are mainly based on image acquisition and processing chips, which connecting to personal computer with USB2.0 circuit, with the faults of expensive, complicated structure, poor portability, and difficult to popularize. To against the shortcomings above, this paper presents the methods of digital signal acquisition and processing specially based on embedded technology with the core hardware structure of ARM and FPGA for substituting the traditional design with USB2.0 and personal computer. With built-in FIFO and dual-buffer, FPGA implement the ping-pong operation of data storage, simultaneously transferring the image data into ARM through the EBI bus by DMA function, which is controlled by ARM to carry out the purpose of high-speed transmission. The ARM system is being chosen to implement the responsibility of image display every time DMA transmission over and actualizing system control with the drivers and applications running on the embedded operating system Windows CE, which could provide a stable, safe and reliable running platform for the embedded device software. Profiting from the excellent graphical user interface (GUI) and good performance of Windows CE, we can not only clearly show 511×511 pixels ultrasonic echo images through application program, but also provide a simple and friendly operating interface with mouse and touch screen which is more convenient than the traditional endoscopic ultrasonic imaging system. Including core and peripheral circuits of FPGA and ARM, power network circuit and LCD display circuit, we designed the whole embedded system, achieving the desired purpose by implementing ultrasonic image display properly after the experimental verification, solving the problem of hugeness and complexity of the traditional endoscopic ultrasonic imaging system.

  12. Integrated biophotonics in endoscopic oncology

    NASA Astrophysics Data System (ADS)

    Muguruma, Naoki; DaCosta, Ralph S.; Wilson, Brian C.; Marcon, Norman E.

    2009-02-01

    Gastrointestinal endoscopy has made great progress during last decade. Diagnostic accuracy can be enhanced by better training, improved dye-contrast techniques method, and the development of new image processing technologies. However, diagnosis using conventional endoscopy with white-light optical imaging is essentially limited by being based on morphological changes and/or visual attribution: hue, saturation and intensity, interpretation of which depends on the endoscopist's eye and brain. In microlesions in the gastrointestinal tract, we still rely ultimately on the histopathological diagnosis from biopsy specimens. Autofluorescence imaging system has been applied for lesions which have been difficult to morphologically recognize or are indistinct with conventional endoscope, and this approach has potential application for the diagnosis of dysplastic lesions and early cancers in the gastrointestinal tract, supplementing the information from white light endoscopy. This system has an advantage that it needs no administration of a photosensitive agent, making it suitable as a screening method for the early detection of neoplastic tissues. Narrow band imaging (NBI) is a novel endoscopic technique which can distinguish neoplastic and non-neoplastic lesions without chromoendoscopy. Magnifying endoscopy in combination with NBI has an obvious advantage, namely analysis of the epithelial pit pattern and the vascular network. This new technique allows a detailed visualization in early neoplastic lesions of esophagus, stomach and colon. However, problems remain; how to combine these technologies in an optimum diagnostic strategy, how to apply them into the algorithm for therapeutic decision-making, and how to standardize several classifications surrounding them. 'Molecular imaging' is a concept representing the most novel imaging methods in medicine, although the definition of the word is still controversial. In the field of gastrointestinal endoscopy, the future of endoscopic diagnosis is likely to be impacted by a combination of biomarkers and technology, and 'endoscopic molecular imaging' should be defined as "visualization of molecular characteristics with endoscopy". These innovations will allow us not only to locate a tumor or dysplastic lesion but also to visualize its molecular characteristics (e.g., DNA mutations and polymorphisms, gene and/or protein expression), and the activity of specific molecules and biological processes that affect tumor behavior and/or its response to therapy. In the near future, these methods should be promising technologies that will play a central role in gastrointestinal oncology.

  13. Algorithm-Based Motion Magnification for Video Processing in Urological Laparoscopy.

    PubMed

    Adams, Fabian; Schoelly, Reto; Schlager, Daniel; Schoenthaler, Martin; Schoeb, Dominik S; Wilhelm, Konrad; Hein, Simon; Wetterauer, Ulrich; Miernik, Arkadiusz

    2017-06-01

    Minimally invasive surgery is in constant further development and has replaced many conventional operative procedures. If vascular structure movement could be detected during these procedures, it could reduce the risk of vascular injury and conversion to open surgery. The recently proposed motion-amplifying algorithm, Eulerian Video Magnification (EVM), has been shown to substantially enhance minimal object changes in digitally recorded video that is barely perceptible to the human eye. We adapted and examined this technology for use in urological laparoscopy. Video sequences of routine urological laparoscopic interventions were recorded and further processed using spatial decomposition and filtering algorithms. The freely available EVM algorithm was investigated for its usability in real-time processing. In addition, a new image processing technology, the CRS iimotion Motion Magnification (CRSMM) algorithm, was specifically adjusted for endoscopic requirements, applied, and validated by our working group. Using EVM, no significant motion enhancement could be detected without severe impairment of the image resolution, motion, and color presentation. The CRSMM algorithm significantly improved image quality in terms of motion enhancement. In particular, the pulsation of vascular structures could be displayed more accurately than in EVM. Motion magnification image processing technology has the potential for clinical importance as a video optimizing modality in endoscopic and laparoscopic surgery. Barely detectable (micro)movements can be visualized using this noninvasive marker-free method. Despite these optimistic results, the technology requires considerable further technical development and clinical tests.

  14. Terahertz endoscopic imaging for colorectal cancer detection: Current status and future perspectives

    PubMed Central

    Doradla, Pallavi; Joseph, Cecil; Giles, Robert H

    2017-01-01

    Terahertz (THz) imaging is progressing as a robust platform for myriad applications in the field of security, health, and material science. The THz regime, which comprises wavelengths spanning from microns to millimeters, is non-ionizing and has very low photon energy: Making it inherently safe for biological imaging. Colorectal cancer is one of the most common causes of death in the world, while the conventional screening and standard of care yet relies exclusively on the physician’s experience. Researchers have been working on the development of a flexible THz endoscope, as a potential tool to aid in colorectal cancer screening. This involves building a single-channel THz endoscope, and profiling the THz response from colorectal tissue, and demonstrating endogenous contrast levels between normal and diseased tissue when imaging in reflection modality. The current level of contrast provided by the prototype THz endoscopic system represents a significant step towards clinical endoscopic application of THz technology for in-vivo colorectal cancer screening. The aim of this paper is to provide a short review of the recent advances in THz endoscopic technology and cancer imaging. In particular, the potential of single-channel THz endoscopic imaging for colonic cancer screening will be highlighted. PMID:28874955

  15. White Paper AGA: Advanced Imaging in Barrett's Esophagus.

    PubMed

    Sharma, Prateek; Brill, Joel; Canto, Marcia; DeMarco, Daniel; Fennerty, Brian; Gupta, Neil; Laine, Loren; Lieberman, David; Lightdale, Charles; Montgomery, Elizabeth; Odze, Robert; Tokar, Jeffrey; Kochman, Michael

    2015-12-01

    Enhanced imaging technologies such as narrow band imaging, flexible spectral imaging color enhancement, i-Scan, confocal laser endomicroscopy, and optical coherence tomography are readily available for use by endoscopists in routine clinical practice. In November 2014, the American Gastroenterological Association's Center for GI Innovation and Technology conducted a 2-day workshop to discuss endoscopic image enhancement technologies, focusing on their role in 2 specific clinical conditions (colon polyps and Barrett's esophagus) and on issues relating to training and implementation of these technologies (white papers). Although the majority of the studies that use enhanced imaging technologies have been positive, these techniques ideally need to be validated in larger cohorts and in community centers. As it stands today, detailed endoscopic examination with high-definition white-light endoscopy and random 4-quadrant biopsy remains the standard of care. However, the workshop panelists agreed that in the hands of endoscopists who have met the preservation and incorporation of valuable endoscopic innovation thresholds (diagnostic accuracy) with enhanced imaging techniques (specific technologies), use of the technique in Barrett's esophagus patients is appropriate. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.

  16. endoscope-i: an innovation in mobile endoscopic technology transforming the delivery of patient care in otolaryngology.

    PubMed

    Mistry, N; Coulson, C; George, A

    2017-11-01

    Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.

  17. Wireless technologies for robotic endoscope in gastrointestinal tract.

    PubMed

    Gao, P; Yan, G; Wang, Z; Liu, H

    2012-07-01

    This paper introduces wireless technologies for use with robotic endoscopes in the gastrointestinal tract. The technologies include wireless power transmission (WPT), wireless remote control (WRC), and wireless image transmission (WIT). WPT, based on the electromagnetic coupling principle, powers active locomotion actuators and other peripherals in large air gaps. WRC, based on real-time bidirectional communication, has a multikernel frame in vivo to realize real-time multitasking. WIT provides a continuous dynamic image with a revolution of 320 × 240 pixel at 30 fps for in vitro diagnosis. To test these wireless technologies, three robotic endoscope prototypes were fabricated and equipped with the customized modules. The experimental results show that the wireless technologies have value for clinical applications.

  18. Scanning fiber endoscopy with highly flexible, 1-mm catheterscopes for wide-field, full-color imaging

    PubMed Central

    Lee, Cameron M.; Engelbrecht, Christoph J.; Soper, Timothy D.; Helmchen, Fritjof; Seibel, Eric J.

    2011-01-01

    In modern endoscopy, wide field of view and full color are considered necessary for navigating inside the body, inspecting tissue for disease and guiding interventions such as biopsy or surgery. Current flexible endoscope technologies suffer from reduced resolution when device diameter shrinks. Endoscopic procedures today using coherent fiber bundle technology, on the scale of 1 mm, are performed with such poor image quality that the clinician’s vision meets the criteria for legal blindness. Here, we review a new and versatile scanning fiber imaging technology and describe its implementation for ultrathin and flexible endoscopy. This scanning fiber endoscope (SFE) or catheterscope enables high quality, laser-based, video imaging for ultrathin clinical applications while also providing new options for in vivo biological research of subsurface tissue and high resolution fluorescence imaging. PMID:20336702

  19. Ultra-high definition (8K UHD) endoscope: our first clinical success.

    PubMed

    Yamashita, Hiromasa; Aoki, Hisae; Tanioka, Kenkichi; Mori, Toshiyuki; Chiba, Toshio

    2016-01-01

    We have started clinical application of 8K ultra-high definition (UHD; 7680 × 4320 pixels) imaging technology, which is a 16-fold higher resolution than the current 2K high-definition (HD; 1920 × 1080 pixels) technology, to an endoscope for advanced laparoscopic surgery. Based on preliminary testing experience and with subsequent technical and system improvements, we then proceeded to perform two cases of cholecystectomy and were able to achieve clinical success with an 8K UHD endoscopic system, which consisted of an 8K camera, a 30-degrees angled rigid endoscope with a lens adapter, a pair of 300-W xenon light sources, an 85-inch 8K LCD and an 8K video recorder. These experimental and clinical studies revealed the engineering and clinical feasibility of the 8K UHD endoscope, enabling us to have a positive outlook on its prospective use in clinical practice. The 8K UHD endoscopy promises to open up new possibilities for intricate procedures including anastomoses of thin nerves and blood vessels as well as more confident surgical resections of a diversity of cancer tissues. 8K endoscopic imaging, compared to imaging by the current 2K imaging technology, is very likely to lead to major changes in the future of medical practice.

  20. Design and modeling of a prototype fiber scanning CARS endoscope

    NASA Astrophysics Data System (ADS)

    Veilleux, Isra"l.; Doucet, Michel; Coté, Patrice; Verreault, Sonia; Fortin, Michel; Paradis, Patrick; Leclair, Sébastien; Da Costa, Ralph S.; Wilson, Brian C.; Seibel, Eric; Mermut, Ozzy; Cormier, Jean-François

    2010-02-01

    An endoscope capable of Coherent Anti-Stokes Raman scattering (CARS) imaging would be of significant clinical value for improving early detection of endoluminal cancers. However, developing this technology is challenging for many reasons. First, nonlinear imaging techniques such as CARS are single point measurements thus requiring fast scanning in a small footprint if video rate is to be achieved. Moreover, the intrinsic nonlinearity of this modality imposes several technical constraints and limitations, mainly related to pulse and beam distortions that occur within the optical fiber and the focusing objective. Here, we describe the design and report modeling results of a new CARS endoscope. The miniature microscope objective design and its anticipated performance are presented, along with its compatibility with a new spiral scanningfiber imaging technology developed at the University of Washington. This technology has ideal attributes for clinical use, with its small footprint, adjustable field-of-view and high spatial-resolution. This compact hybrid fiber-based endoscopic CARS imaging design is anticipated to have a wide clinical applicability.

  1. Comparison of methods for quantitative evaluation of endoscopic distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Castro, Kurt; Desai, Viraj N.; Cheng, Wei-Chung; Pfefer, Joshua

    2015-03-01

    Endoscopy is a well-established paradigm in medical imaging, and emerging endoscopic technologies such as high resolution, capsule and disposable endoscopes promise significant improvements in effectiveness, as well as patient safety and acceptance of endoscopy. However, the field lacks practical standardized test methods to evaluate key optical performance characteristics (OPCs), in particular the geometric distortion caused by fisheye lens effects in clinical endoscopic systems. As a result, it has been difficult to evaluate an endoscope's image quality or assess its changes over time. The goal of this work was to identify optimal techniques for objective, quantitative characterization of distortion that are effective and not burdensome. Specifically, distortion measurements from a commercially available distortion evaluation/correction software package were compared with a custom algorithm based on a local magnification (ML) approach. Measurements were performed using a clinical gastroscope to image square grid targets. Recorded images were analyzed with the ML approach and the commercial software where the results were used to obtain corrected images. Corrected images based on the ML approach and the software were compared. The study showed that the ML method could assess distortion patterns more accurately than the commercial software. Overall, the development of standardized test methods for characterizing distortion and other OPCs will facilitate development, clinical translation, manufacturing quality and assurance of performance during clinical use of endoscopic technologies.

  2. Proof-of-concept of a laser mounted endoscope for touch-less navigated procedures

    PubMed Central

    Kral, Florian; Gueler, Oezguer; Perwoeg, Martina; Bardosi, Zoltan; Puschban, Elisabeth J; Riechelmann, Herbert; Freysinger, Wolfgang

    2013-01-01

    Background and Objectives During navigated procedures a tracked pointing device is used to define target structures in the patient to visualize its position in a registered radiologic data set. When working with endoscopes in minimal invasive procedures, the target region is often difficult to reach and changing instruments is disturbing in a challenging, crucial moment of the procedure. We developed a device for touch less navigation during navigated endoscopic procedures. Materials and Methods A laser beam is delivered to the tip of a tracked endoscope angled to its axis. Thereby the position of the laser spot in the video-endoscopic images changes according to the distance between the tip of the endoscope and the target structure. A mathematical function is defined by a calibration process and is used to calculate the distance between the tip of the endoscope and the target. The tracked tip of the endoscope and the calculated distance is used to visualize the laser spot in the registered radiologic data set. Results In comparison to the tracked instrument, the touch less target definition with the laser spot yielded in an over and above error of 0.12 mm. The overall application error in this experimental setup with a plastic head was 0.61 ± 0.97 mm (95% CI −1.3 to +2.5 mm). Conclusion Integrating a laser in an endoscope and then calculating the distance to a target structure by image processing of the video endoscopic images is accurate. This technology eliminates the need for tracked probes intraoperatively and therefore allows navigation to be integrated seamlessly in clinical routine. However, it is an additional chain link in the sequence of computer-assisted surgery thus influencing the application error. Lasers Surg. Med. 45:377–382, 2013. © 2013 Wiley Periodicals, Inc. PMID:23737122

  3. Variety and evolution of American endoscopic image management and recording systems.

    PubMed

    Korman, L Y

    1996-03-01

    The rapid evolution of computing technology has and will continue to alter the practice of gastroenterology and gastrointestinal endoscopy. Development of communication standards for text, images, and security systems will be necessary for medicine to take advantage of high-speed computing and communications. Professional societies can have an important role in guiding the development process.

  4. Image Quality Analysis of Various Gastrointestinal Endoscopes: Why Image Quality Is a Prerequisite for Proper Diagnostic and Therapeutic Endoscopy

    PubMed Central

    Ko, Weon Jin; An, Pyeong; Ko, Kwang Hyun; Hahm, Ki Baik; Hong, Sung Pyo

    2015-01-01

    Arising from human curiosity in terms of the desire to look within the human body, endoscopy has undergone significant advances in modern medicine. Direct visualization of the gastrointestinal (GI) tract by traditional endoscopy was first introduced over 50 years ago, after which fairly rapid advancement from rigid esophagogastric scopes to flexible scopes and high definition videoscopes has occurred. In an effort towards early detection of precancerous lesions in the GI tract, several high-technology imaging scopes have been developed, including narrow band imaging, autofocus imaging, magnified endoscopy, and confocal microendoscopy. However, these modern developments have resulted in fundamental imaging technology being skewed towards red-green-blue and this technology has obscured the advantages of other endoscope techniques. In this review article, we have described the importance of image quality analysis using a survey to consider the diversity of endoscope system selection in order to better achieve diagnostic and therapeutic goals. The ultimate aims can be achieved through the adoption of modern endoscopy systems that obtain high image quality. PMID:26473119

  5. 4-mm-diameter three-dimensional imaging endoscope with steerable camera for minimally invasive surgery (3-D-MARVEL).

    PubMed

    Bae, Sam Y; Korniski, Ronald J; Shearn, Michael; Manohara, Harish M; Shahinian, Hrayr

    2017-01-01

    High-resolution three-dimensional (3-D) imaging (stereo imaging) by endoscopes in minimally invasive surgery, especially in space-constrained applications such as brain surgery, is one of the most desired capabilities. Such capability exists at larger than 4-mm overall diameters. We report the development of a stereo imaging endoscope of 4-mm maximum diameter, called Multiangle, Rear-Viewing Endoscopic Tool (MARVEL) that uses a single-lens system with complementary multibandpass filter (CMBF) technology to achieve 3-D imaging. In addition, the system is endowed with the capability to pan from side-to-side over an angle of [Formula: see text], which is another unique aspect of MARVEL for such a class of endoscopes. The design and construction of a single-lens, CMBF aperture camera with integrated illumination to generate 3-D images, and the actuation mechanism built into it is summarized.

  6. A Look from the Inside

    NASA Technical Reports Server (NTRS)

    2004-01-01

    NASA's Hubble Space Telescope has given the world amazing images of the distant stars, planets, and galaxies. The cutting-edge imaging technology that enhances the Hubble images also extends its benefits to life here on Earth, from deciphering previously unreadable portions of the Dead Sea Scrolls to improving digital mammographies for advanced cancer detection. This imaging technology is now helping physicians to perform micro-invasive arthroscopic surgery, which is the visual examination of an interior joint such as the knee. In 1997, NASA's Glenn Research Center signed a Space Act Agreement with Micro Medical Devices, Inc. (MMD), a medical device engineering company that licenses miniature surgical devices. At that time, MMD was in the process of developing a new micro-endoscope. This tool enables surgeons to view what is happening inside the body on a screen, eliminating the need for a more invasive diagnostic procedure. The images from the micro-endoscope needed to be extremely clear, a challenge with the tool s small size. The images also needed to be viewed in real time to allow surgeons to see what was happening in the body at that very moment. MMD established Clear Image Technology, LLC, of Elyria, Ohio, to commercialize the miniature endoscope. Clear Image Technology then partnered with Arthrotek, Inc., a sports medicine subsidiary of Biomet, Inc., to introduce the tool to the commercial market as the InnerVue[TM] Diagnostic Scope System. The InnerVue system is designed for use in a diagnostic environment, such as an office or outpatient service, to evaluate conditions within a joint. While the InnerVue scope is primarily being applied to the knee and shoulder, other small joints such as the wrist, elbow, and ankle are being investigated. A physician can use the system alone or in conjunction with magnetic resonance imaging (MRI) to determine the next treatment step for each patient. The procedure can be more accurate than MRI, particularly with diagnosing cartilage and articular surface damage and assessing arthritis severity.

  7. A wireless narrowband imaging chip for capsule endoscope.

    PubMed

    Lan-Rong Dung; Yin-Yi Wu

    2010-12-01

    This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis.

  8. Microarthroscopy System With Image Processing Technology Developed for Minimally Invasive Surgery

    NASA Technical Reports Server (NTRS)

    Steele, Gynelle C.

    2001-01-01

    In a joint effort, NASA, Micro Medical Devices, and the Cleveland Clinic have developed a microarthroscopy system with digital image processing. This system consists of a disposable endoscope the size of a needle that is aimed at expanding the use of minimally invasive surgery on the knee, ankle, and other small joints. This device not only allows surgeons to make smaller incisions (by improving the clarity and brightness of images), but it gives them a better view of the injured area to make more accurate diagnoses. Because of its small size, the endoscope helps reduce physical trauma and speeds patient recovery. The faster recovery rate also makes the system cost effective for patients. The digital image processing software used with the device was originally developed by the NASA Glenn Research Center to conduct computer simulations of satellite positioning in space. It was later modified to reflect lessons learned in enhancing photographic images in support of the Center's microgravity program. Glenn's Photovoltaic Branch and Graphics and Visualization Lab (G-VIS) computer programmers and software developers enhanced and speed up graphic imaging for this application. Mary Vickerman at Glenn developed algorithms that enabled Micro Medical Devices to eliminate interference and improve the images.

  9. Quantitative evaluation of three advanced laparoscopic viewing technologies: a stereo endoscope, an image projection display, and a TFT display.

    PubMed

    Wentink, M; Jakimowicz, J J; Vos, L M; Meijer, D W; Wieringa, P A

    2002-08-01

    Compared to open surgery, minimally invasive surgery (MIS) relies heavily on advanced technology, such as endoscopic viewing systems and innovative instruments. The aim of the study was to objectively compare three technologically advanced laparoscopic viewing systems with the standard viewing system currently used in most Dutch hospitals. We evaluated the following advanced laparoscopic viewing systems: a Thin Film Transistor (TFT) display, a stereo endoscope, and an image projection display. The standard viewing system was comprised of a monocular endoscope and a high-resolution monitor. Task completion time served as the measure of performance. Eight surgeons with laparoscopic experience participated in the experiment. The average task time was significantly greater (p <0.05) with the stereo viewing system than with the standard viewing system. The average task times with the TFT display and the image projection display did not differ significantly from the standard viewing system. Although the stereo viewing system promises improved depth perception and the TFT and image projection displays are supposed to improve hand-eye coordination, none of these systems provided better task performance than the standard viewing system in this pelvi-trainer experiment.

  10. Endoscopic optical coherence tomography: technologies and clinical applications [Invited

    PubMed Central

    Gora, Michalina J.; Suter, Melissa J.; Tearney, Guillermo J.; Li, Xingde

    2017-01-01

    In this paper, we review the current state of technology development and clinical applications of endoscopic optical coherence tomography (OCT). Key design and engineering considerations are discussed for most OCT endoscopes, including side-viewing and forward-viewing probes, along with different scanning mechanisms (proximal-scanning versus distal-scanning). Multi-modal endoscopes that integrate OCT with other imaging modalities are also discussed. The review of clinical applications of endoscopic OCT focuses heavily on diagnosis of diseases and guidance of interventions. Representative applications in several organ systems are presented, such as in the cardiovascular, digestive, respiratory, and reproductive systems. A brief outlook of the field of endoscopic OCT is also discussed. PMID:28663882

  11. [Digital imaging and robotics in endoscopic surgery].

    PubMed

    Go, P M

    1998-05-23

    The introduction of endoscopical surgery has among other things influenced technical developments in surgery. Owing to digitalisation, major progress will be made in imaging and in the sophisticated technology sometimes called robotics. Digital storage makes the results of imaging diagnostics (e.g. the results of radiological examination) suitable for transmission via video conference systems for telediagnostic purposes. The availability of digital video technique renders possible the processing, storage and retrieval of moving images as well. During endoscopical operations use may be made of a robot arm which replaces the camera man. The arm does not grow tired and provides a stable image. The surgeon himself can operate or address the arm and it can remember fixed image positions to which it can return if ordered to do so. The next step is to carry out surgical manipulations via a robot arm. This may make operations more patient-friendly. A robot arm can also have remote control: telerobotics. At the Internet site of this journal a number of supplements to this article can be found, for instance three-dimensional (3D) illustrations (which is the purpose of the 3D spectacles enclosed with this issue) and a quiz (http:@appendix.niwi. knaw.nl).

  12. A Wireless Capsule Endoscope System With Low-Power Controlling and Processing ASIC.

    PubMed

    Xinkai Chen; Xiaoyu Zhang; Linwei Zhang; Xiaowen Li; Nan Qi; Hanjun Jiang; Zhihua Wang

    2009-02-01

    This paper presents the design of a wireless capsule endoscope system. The proposed system is mainly composed of a CMOS image sensor, a RF transceiver and a low-power controlling and processing application specific integrated circuit (ASIC). Several design challenges involving system power reduction, system miniaturization and wireless wake-up method are resolved by employing optimized system architecture, integration of an area and power efficient image compression module, a power management unit (PMU) and a novel wireless wake-up subsystem with zero standby current in the ASIC design. The ASIC has been fabricated in 0.18-mum CMOS technology with a die area of 3.4 mm * 3.3 mm. The digital baseband can work under a power supply down to 0.95 V with a power dissipation of 1.3 mW. The prototype capsule based on the ASIC and a data recorder has been developed. Test result shows that proposed system architecture with local image compression lead to an average of 45% energy reduction for transmitting an image frame.

  13. Sparse aperture endoscope

    DOEpatents

    Fitch, J.P.

    1999-07-06

    An endoscope is disclosed which reduces the volume needed by the imaging part, maintains resolution of a wide diameter optical system, while increasing tool access, and allows stereographic or interferometric processing for depth and perspective information/visualization. Because the endoscope decreases the volume consumed by imaging optics such allows a larger fraction of the volume to be used for non-imaging tools, which allows smaller incisions in surgical and diagnostic medical applications thus produces less trauma to the patient or allows access to smaller volumes than is possible with larger instruments. The endoscope utilizes fiber optic light pipes in an outer layer for illumination, a multi-pupil imaging system in an inner annulus, and an access channel for other tools in the center. The endoscope is amenable to implementation as a flexible scope, and thus increases it's utility. Because the endoscope uses a multi-aperture pupil, it can also be utilized as an optical array, allowing stereographic and interferometric processing. 7 figs.

  14. Sparse aperture endoscope

    DOEpatents

    Fitch, Joseph P.

    1999-07-06

    An endoscope which reduces the volume needed by the imaging part thereof, maintains resolution of a wide diameter optical system, while increasing tool access, and allows stereographic or interferometric processing for depth and perspective information/visualization. Because the endoscope decreases the volume consumed by imaging optics such allows a larger fraction of the volume to be used for non-imaging tools, which allows smaller incisions in surgical and diagnostic medical applications thus produces less trauma to the patient or allows access to smaller volumes than is possible with larger instruments. The endoscope utilizes fiber optic light pipes in an outer layer for illumination, a multi-pupil imaging system in an inner annulus, and an access channel for other tools in the center. The endoscope is amenable to implementation as a flexible scope, and thus increases the utility thereof. Because the endoscope uses a multi-aperture pupil, it can also be utilized as an optical array, allowing stereographic and interferometric processing.

  15. The Role of Adjunct Imaging in Endoscopic Detection of Dysplasia in Barrett's Esophagus.

    PubMed

    Kandel, Pujan; Wallace, Michael B

    2017-07-01

    Advances in imaging technologies have demonstrated promise in early detection of dysplasia and cancer in Barrett's esophagus (BE). Optical chromoendoscopy, dye-based chromoendoscopy, and novel technologies have provided the opportunity to visualize the cellular and subcellular structures. Only narrow-band imaging and acetic acid chromoendoscopy have reached benchmarks for clinical use. Volumetric laser endomicroscopy and molecular imaging are not established for routine use. Best practice in management of BE should be focused on careful endoscopic examination, resection, or ablation of the entire abnormal lesion, as well as the use of available imaging technique that has good diagnostic accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Image-enhanced endoscopy with I-scan technology for the evaluation of duodenal villous patterns.

    PubMed

    Cammarota, Giovanni; Ianiro, Gianluca; Sparano, Lucia; La Mura, Rossella; Ricci, Riccardo; Larocca, Luigi M; Landolfi, Raffaele; Gasbarrini, Antonio

    2013-05-01

    I-scan technology is the newly developed endoscopic tool that works in real time and utilizes a digital contrast method to enhance endoscopic image. We performed a feasibility study aimed to determine the diagnostic accuracy of i-scan technology for the evaluation of duodenal villous patterns, having histology as the reference standard. In this prospective, single center, open study, patients undergoing upper endoscopy for an histological evaluation of duodenal mucosa were enrolled. All patients underwent upper endoscopy using high resolution view in association with i-scan technology. During endoscopy, duodenal villous patterns were evaluated and classified as normal, partial villous atrophy, or marked villous atrophy. Results were then compared with histology. One hundred fifteen subjects were recruited in this study. The endoscopist was able to find marked villous atrophy of the duodenum in 12 subjects, partial villous atrophy in 25, and normal villi in the remaining 78 individuals. The i-scan system was demonstrated to have great accuracy (100 %) in the detection of marked villous atrophy patterns. I-scan technology showed quite lower accuracy in determining partial villous atrophy or normal villous patterns (respectively, 90 % for both items). Image-enhancing endoscopic technology allows a clear visualization of villous patterns in the duodenum. By switching from the standard to the i-scan view, it is possible to optimize the accuracy of endoscopy in recognizing villous alteration in subjects undergoing endoscopic evaluation.

  17. The combination design for open and endoscopic surgery using fluorescence molecular imaging technology

    NASA Astrophysics Data System (ADS)

    Mao, Yamin; Jiang, Shixin; Ye, Jinzuo; An, Yu; Yang, Xin; Chi, Chongwei; Tian, Jie

    2015-03-01

    For clinical surgery, it is still a challenge to objectively determine tumor margins during surgery. With the development of medical imaging technology, fluorescence molecular imaging (FMI) method can provide real-time intraoperative tumor margin information. Furthermore, surgical navigation system based on FMI technology plays an important role for the aid of surgeons' precise tumor margin decision. However, detection depth is the most limitation exists in the FMI technique and the method convenient for either macro superficial detection or micro deep tissue detection is needed. In this study, we combined advantages of both open surgery and endoscopic imaging systems with FMI technology. Indocyanine green (ICG) experiments were performed to confirm the feasibility of fluorescence detection in our system. Then, the ICG signal was photographed in the detection area with our system. When the system connected with endoscope lens, the minimum quantity of ICG detected by our system was 0.195 ug. For aspect of C mount lens, the sensitivity of ICG detection with our system was 0.195ug. Our experiments results proved that it was feasible to detect fluorescence images with this combination method. Our system shows great potential in the clinical applications of precise dissection of various tumors

  18. Ultrahigh sensitivity endoscopic camera using a new CMOS image sensor: providing with clear images under low illumination in addition to fluorescent images.

    PubMed

    Aoki, Hisae; Yamashita, Hiromasa; Mori, Toshiyuki; Fukuyo, Tsuneo; Chiba, Toshio

    2014-11-01

    We developed a new ultrahigh-sensitive CMOS camera using a specific sensor that has a wide range of spectral sensitivity characteristics. The objective of this study is to present our updated endoscopic technology that has successfully integrated two innovative functions; ultrasensitive imaging as well as advanced fluorescent viewing. Two different experiments were conducted. One was carried out to evaluate the function of the ultrahigh-sensitive camera. The other was to test the availability of the newly developed sensor and its performance as a fluorescence endoscope. In both studies, the distance from the endoscopic tip to the target was varied and those endoscopic images in each setting were taken for further comparison. In the first experiment, the 3-CCD camera failed to display the clear images under low illumination, and the target was hardly seen. In contrast, the CMOS camera was able to display the targets regardless of the camera-target distance under low illumination. Under high illumination, imaging quality given by both cameras was quite alike. In the second experiment as a fluorescence endoscope, the CMOS camera was capable of clearly showing the fluorescent-activated organs. The ultrahigh sensitivity CMOS HD endoscopic camera is expected to provide us with clear images under low illumination in addition to the fluorescent images under high illumination in the field of laparoscopic surgery.

  19. Endoscopic Skull Base Surgery

    PubMed Central

    Senior, Brent A

    2008-01-01

    Endoscopic skull base surgery has undergone rapid advancement in the past decade moving from pituitary surgery to suprasellar lesions and now to a myriad of lesions extending from the cribriform plate to C2 and laterally out to the infratemporal fossa and petrous apex. Evolution of several technological advances as well as advances in understanding of endoscopic anatomy and the development of surgical techniques both in resection and reconstruction have fostered this capability. Management of benign disease via endoscopic methods is largely accepted now but more data is needed before the controversy on the role of endoscopic management of malignant disease is decided. Continued advances in surgical technique, navigation systems, endoscopic imaging technology, and robotics assure continued brisk evolution in this expanding field. PMID:19434274

  20. Progress in molecular imaging in endoscopy and endomicroscopy for cancer imaging

    PubMed Central

    Khondee, Supang; Wang, Thomas D.

    2014-01-01

    Imaging is an essential tool for effective cancer management. Endoscopes are important medical instruments for performing in vivo imaging in hollow organs. Early detection of cancer can be achieved with surveillance using endoscopy, and has been shown to reduce mortality and to improve outcomes. Recently, great advancements have been made in endoscopic instruments, including new developments in optical designs, light sources, optical fibers, miniature scanners, and multimodal systems, allowing for improved resolution, greater tissue penetration, and multispectral imaging. In addition, progress has been made in the development of highly-specific optical probes, allowing for improved specificity for molecular targets. Integration of these new endoscopic instruments with molecular probes provides a unique opportunity for significantly improving patient outcomes and has potential to further improve early detection, image guided therapy, targeted therapy, and personalized medicine. This work summarizes current and evolving endoscopic technologies, and provides an overview of various promising optical molecular probes. PMID:23502247

  1. Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration.

    PubMed

    Nikitichev, Daniil I; Shakir, Dzhoshkun I; Chadebecq, François; Tella, Marcel; Deprest, Jan; Stoyanov, Danail; Ourselin, Sébastien; Vercauteren, Tom

    2017-02-23

    We have developed a calibration target for use with fluid-immersed endoscopes within the context of the GIFT-Surg (Guided Instrumentation for Fetal Therapy and Surgery) project. One of the aims of this project is to engineer novel, real-time image processing methods for intra-operative use in the treatment of congenital birth defects, such as spina bifida and the twin-to-twin transfusion syndrome. The developed target allows for the sterility-preserving optical distortion calibration of endoscopes within a few minutes. Good optical distortion calibration and compensation are important for mitigating undesirable effects like radial distortions, which not only hamper accurate imaging using existing endoscopic technology during fetal surgery, but also make acquired images less suitable for potentially very useful image computing applications, like real-time mosaicing. In this paper proposes a novel fabrication method to create an affordable, sterilizable calibration target suitable for use in a clinical setup. This method involves etching a calibration pattern by laser cutting a sandblasted stainless steel sheet. This target was validated using the camera calibration module provided by OpenCV, a state-of-the-art software library popular in the computer vision community.

  2. Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration

    PubMed Central

    Chadebecq, François; Tella, Marcel; Deprest, Jan; Stoyanov, Danail; Ourselin, Sébastien; Vercauteren, Tom

    2017-01-01

    We have developed a calibration target for use with fluid-immersed endoscopes within the context of the GIFT-Surg (Guided Instrumentation for Fetal Therapy and Surgery) project. One of the aims of this project is to engineer novel, real-time image processing methods for intra-operative use in the treatment of congenital birth defects, such as spina bifida and the twin-to-twin transfusion syndrome. The developed target allows for the sterility-preserving optical distortion calibration of endoscopes within a few minutes. Good optical distortion calibration and compensation are important for mitigating undesirable effects like radial distortions, which not only hamper accurate imaging using existing endoscopic technology during fetal surgery, but also make acquired images less suitable for potentially very useful image computing applications, like real-time mosaicing. In this paper proposes a novel fabrication method to create an affordable, sterilizable calibration target suitable for use in a clinical setup. This method involves etching a calibration pattern by laser cutting a sandblasted stainless steel sheet. This target was validated using the camera calibration module provided by OpenCV, a state-of-the-art software library popular in the computer vision community. PMID:28287588

  3. Ultrahigh-resolution endoscopic optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Chen, Yu; Herz, Paul R.; Hsiung, Pei-Lin; Aguirre, Aaron D.; Mashimo, Hiroshi; Desai, Saleem; Pedrosa, Macos; Koski, Amanda; Schmitt, Joseph M.; Fujimoto, James G.

    2005-01-01

    Early detection of gastrointestinal cancer is essential for the patient treatment and medical care. Endoscopically guided biopsy is currently the gold standard for the diagnosis of early esophageal cancer, but can suffer from high false negative rates due to sampling errors. Optical coherence tomography (OCT) is an emerging medical imaging technology which can generate high resolution, cross-sectional images of tissue in situ and in real time, without the removal of tissue specimen. Although endoscopic OCT has been used successfully to identify certain pathologies in the gastrointestinal tract, the resolution of current endoscopic OCT systems has been limited to 10 - 15 m for clinical procedures. In this study, in vivo imaging of the gastrointestinal tract is demonstrated at a three-fold higher resolution (< 5 m), using a portable, broadband, Cr4+:Forsterite laser as the optical light source. Images acquired from the esophagus, gastro-esophageal junction and colon on animal model display tissue microstructures and architectural details at high resolution, and the features observed in the OCT images are well-matched with histology. The clinical feasibility study is conducted through delivering OCT imaging catheter using standard endoscope. OCT images of normal esophagus, Barrett's esophagus, and esophageal cancers are demonstrated with distinct features. The ability of high resolution endoscopic OCT to image tissue morphology at an unprecedented resolution in vivo would facilitate the development of OCT as a potential imaging modality for early detection of neoplastic changes.

  4. A Review of Optical NDT Technologies

    PubMed Central

    Zhu, Yong-Kai; Tian, Gui-Yun; Lu, Rong-Sheng; Zhang, Hong

    2011-01-01

    Optical non-destructive testing (NDT) has gained more and more attention in recent years, mainly because of its non-destructive imaging characteristics with high precision and sensitivity. This paper provides a review of the main optical NDT technologies, including fibre optics, electronic speckle, infrared thermography, endoscopic and terahertz technology. Among them, fibre optics features easy integration and embedding, electronic speckle focuses on whole-field high precision detection, infrared thermography has unique advantages for tests of combined materials, endoscopic technology provides images of the internal surface of the object directly, and terahertz technology opens a new direction of internal NDT because of its excellent penetration capability to most of non-metallic materials. Typical engineering applications of these technologies are illustrated, with a brief introduction of the history and discussion of recent progress. PMID:22164045

  5. Recent advances in targeted endoscopic imaging: Early detection of gastrointestinal neoplasms

    PubMed Central

    Kwon, Yong-Soo; Cho, Young-Seok; Yoon, Tae-Jong; Kim, Ho-Shik; Choi, Myung-Gyu

    2012-01-01

    Molecular imaging has emerged as a new discipline in gastrointestinal endoscopy. This technology encompasses modalities that can visualize disease-specific morphological or functional tissue changes based on the molecular signature of individual cells. Molecular imaging has several advantages including minimal damage to tissues, repetitive visualization, and utility for conducting quantitative analyses. Advancements in basic science coupled with endoscopy have made early detection of gastrointestinal cancer possible. Molecular imaging during gastrointestinal endoscopy requires the development of safe biomarkers and exogenous probes to detect molecular changes in cells with high specificity anda high signal-to-background ratio. Additionally, a high-resolution endoscope with an accurate wide-field viewing capability must be developed. Targeted endoscopic imaging is expected to improve early diagnosis and individual therapy of gastrointestinal cancer. PMID:22442742

  6. A discriminative structural similarity measure and its application to video-volume registration for endoscope three-dimensional motion tracking.

    PubMed

    Luo, Xiongbiao; Mori, Kensaku

    2014-06-01

    Endoscope 3-D motion tracking, which seeks to synchronize pre- and intra-operative images in endoscopic interventions, is usually performed as video-volume registration that optimizes the similarity between endoscopic video and pre-operative images. The tracking performance, in turn, depends significantly on whether a similarity measure can successfully characterize the difference between video sequences and volume rendering images driven by pre-operative images. The paper proposes a discriminative structural similarity measure, which uses the degradation of structural information and takes image correlation or structure, luminance, and contrast into consideration, to boost video-volume registration. By applying the proposed similarity measure to endoscope tracking, it was demonstrated to be more accurate and robust than several available similarity measures, e.g., local normalized cross correlation, normalized mutual information, modified mean square error, or normalized sum squared difference. Based on clinical data evaluation, the tracking error was reduced significantly from at least 14.6 mm to 4.5 mm. The processing time was accelerated more than 30 frames per second using graphics processing unit.

  7. An Automated Self-Learning Quantification System to Identify Visible Areas in Capsule Endoscopy Images.

    PubMed

    Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao

    2017-08-01

    Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.

  8. Microelectromechanical-System-Based Variable-Focus Liquid Lens for Capsule Endoscopes

    NASA Astrophysics Data System (ADS)

    Seo, Sang Won; Han, Seungoh; Seo, Jun Ho; Kim, Young Mok; Kang, Moon Sik; Min, Nam Ki; Choi, Woo Beom; Sung, Man Young

    2009-05-01

    A liquid lens based on the electrowetting phenomenon was designed to be cylindrical to minimize dead area. The lens was fabricated with microelectromechanical-system (MEMS) technology using silicon thin film and wafer bonding processes. A multiple dielectric layer comprising Teflon, silicon nitride, and thermal oxide was formed on the cylinder wall. With a change of 11 Vrms in the applied bias, the lens module, including the fabricated liquid lens, showed a focal length change of approximately 166 mm. A capsule endoscope was assembled, including the lens module, and was successfully used to take images of a pig colon at various focal lengths.

  9. Development of terahertz endoscopic system for cancer detection

    NASA Astrophysics Data System (ADS)

    Doradla, Pallavi; Alavi, Karim; Joseph, Cecil S.; Giles, Robert H.

    2016-02-01

    Terahertz (THz) imaging is emerging as a robust platform for a myriad of applications in the fields of security, health, astronomy and material science. The terahertz regime with wavelengths spanning from microns to millimeters is a potentially safe and noninvasive medical imaging modality for detecting cancers. Endoscopic imaging systems provide high flexibility in examining the interior surfaces of an organ or tissue. Researchers have been working on the development of THz endoscopes with photoconductive antennas, which necessarily operate under high voltage, and require at least two channels to measure the reflected signal from the specimen. This manuscript provides the design and imperative steps involved in the development of a single-channel terahertz endoscopic system. The continuous-wave terahertz imaging system utilizes a single flexible terahertz waveguide channel to transmit and collect the back reflected intrinsic terahertz signal from the sample and is capable of operation in both transmission and reflection modalities. To determine the feasibility of using a terahertz endoscope for cancer detection, the co- and cross-polarized terahertz remittance from human colonic tissue specimens were collected at 584 GHz frequency. The two dimensional terahertz images obtained using polarization specific detection exhibited intrinsic contrast between cancerous and normal regions of fresh colorectal tissue. The level of contrast observed using endoscopic imaging correlates well with the contrast levels observed in the free space ex vivo terahertz reflectance studies of human colonic tissue. The prototype device developed in this study represents a significant step towards clinical endoscopic application of THz technology for in vivo colon cancer screening.

  10. Doppler imaging using spectrally-encoded endoscopy

    PubMed Central

    Yelin, Dvir; Bouma, B. E.; Rosowsky, J. J.; Tearney, G. J.

    2009-01-01

    The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique that utilizes a single optical fiber and miniature diffractive optics to obtain endoscopic images through small diameter probes. Using spectral-domain interferometry, SEE is furthermore capable of three-dimensional volume imaging at video rates. Here we show that by measuring relative spectral phases, this technology can additionally measure Doppler shifts. Doppler SEE is demonstrated in flowing Intralipid phantoms and vibrating middle ear ossicles. PMID:18795020

  11. New endoscopic and cytologic tools for cancer surveillance in the digestive tract

    PubMed Central

    Brentnall, Teresa A.; Dominitz, Jason A.

    2009-01-01

    Synopsis Cancer surveillance is an increasing part of everyday practice in gastrointestinal endoscopy due to the identification of high risk groups from genetic and biomarker testing, genealogic and epidemiologic studies, and the increasing number of cancer survivors. An efficient surveillance program requires a cost-effective means for image-guided cancer detection and biopsy. A laser-based tethered-capsule endoscope with enhanced spectral imaging is introduced for unsedated surveillance of the lower esophagus. An ultrathin version of this same endoscope technology provides a 1.2-mm guidewire with imaging capability and cannula-style tools are proposed for image-guided biopsy. Advanced 3D cell visualization techniques are described for increasing the sensitivity of early cancer diagnosis from hematoxylin-stained cells sampled from the pancreatic and biliary ducts. PMID:19423026

  12. Spectral-domain optical coherence tomography for endoscopic imaging

    NASA Astrophysics Data System (ADS)

    Chen, Xiaodong; Li, Qiao; Li, Wanhui; Wang, Yi; Yu, Daoyin

    2007-02-01

    Optical coherence tomography (OCT) is an emerging cross-sectional imaging technology. It uses broadband light sources to achieve axial image resolutions on the few micron scale. OCT is widely applied to medical imaging, it can get cross-sectional image of bio-tissue (transparent and turbid) with non-invasion and non-touch. In this paper, the principle of OCT is presented and the crucial parameters of the system are discussed in theory. With analysis of different methods and medical endoscopic system's feature, a design which combines the spectral domain OCT (SDOCT) technique and endoscopy is put forward. SDOCT provides direct access to the spectrum of the optical signal. It is shown to provide higher imaging speed when compared to time domain OCT. At the meantime, a novel OCT probe which uses advanced micromotor to drive reflecting prism is designed according to alimentary tract endoscopic feature. A simple optical coherence tomography system has been developed based on a fiber-based Michelson interferometer and spectrometer. An experiment which uses motor to drive prism to realize rotating imaging is done. Images obtained with this spectral interferometer are presented. The results verify the feasibility of endoscopic optical coherence tomography system with rotating scan.

  13. Navigation technique for MR-endoscope system using a wireless accelerometer-based remote control device.

    PubMed

    Kumamoto, Etsuko; Takahashi, Akihiro; Matsuoka, Yuichiro; Morita, Yoshinori; Kutsumi, Hiromu; Azuma, Takeshi; Kuroda, Kagayaki

    2013-01-01

    The MR-endoscope system can perform magnetic resonance (MR) imaging during endoscopy and show the images obtained by using endoscope and MR. The MR-endoscope system can acquire a high-spatial resolution MR image with an intraluminal radiofrequency (RF) coil, and the navigation system shows the scope's location and orientation inside the human body and indicates MR images with a scope view. In order to conveniently perform an endoscopy and MR procedure, the design of the user interface is very important because it provides useful information. In this study, we propose a navigation system using a wireless accelerometer-based controller with Bluetooth technology and a navigation technique to set the intraluminal RF coil using the navigation system. The feasibility of using this wireless controller in the MR shield room was validated via phantom examinations of the influence on MR procedures and navigation accuracy. In vitro examinations using an isolated porcine stomach demonstrated the effectiveness of the navigation technique using a wireless remote-control device.

  14. Endoscopic and keyhole endoscope-assisted neurosurgical approaches: a qualitative survey on technical challenges and technological solutions.

    PubMed

    Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2014-10-01

    The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent theme analysis. Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches.

  15. Endoscopic and Keyhole Endoscope-assisted Neurosurgical Approaches: A Qualitative Survey on Technical Challenges and Technological Solutions

    PubMed Central

    Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2014-01-01

    Introduction The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. Materials and Methods All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent themes analysis. Results Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). Discussion The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Conclusions Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches. PMID:24533591

  16. Design of a modified endoscope illuminator for spectral imaging of colorectal tissues

    NASA Astrophysics Data System (ADS)

    Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.

    2017-02-01

    The gold standard for locating colonic polyps is a white light endoscope in a colonoscopy, however, polyps smaller than 5 mm can be easily missed. Modified procedures such as narrow band imaging have shown only marginal increases in detection rates. Spectral imaging is a potential solution to improve the sensitivity and specificity of colonoscopies by providing the ability to distinguish molecular fluorescence differences in tissues. The goal of this work is to implement a spectral endoscopic light source to acquire spectral image data of colorectal tissues. A beta-version endoscope light source was developed, by retrofitting a white light endoscope light source (Olympus, CLK-4) with 16 narrow band LEDs. This redesigned, beta-prototype uses high-power LEDs with a minimum output of 500 mW to provide sufficient spectral output (0.5 mW) through the endoscope. A mounting apparatus was designed to provide sufficient heat dissipation. Here, we report recent results of our tests to characterize the intensity output through the light source and endoscope to determine the flat spectral output for imaging and intensity losses through the endoscope. We also report preliminary spectral imaging data from transverse pig colon that demonstrates the ability to result in working practical spectral data. Preliminary results of this revised prototype spectral endoscope system demonstrate that there is sufficient power to allow the imaging process to continue and potentially determine spectral differences in cancerous and normal tissue from imaging ex vivo pairs. Future work will focus on building a spectral library for the colorectal region and refining the user interface the system for in vivo use.

  17. Applying LED in full-field optical coherence tomography for gastrointestinal endoscopy

    NASA Astrophysics Data System (ADS)

    Yang, Bor-Wen; Wang, Yu-Yen; Juan, Yu-Shan; Hsu, Sheng-Jie

    2015-08-01

    Optical coherence tomography (OCT) has become an important medical imaging technology due to its non-invasiveness and high resolution. Full-field optical coherence tomography (FF-OCT) is a scanning scheme especially suitable for en face imaging as it employs a CMOS/CCD device for parallel pixels processing. FF-OCT can also be applied to high-speed endoscopic imaging. Applying cylindrical scanning and a right-angle prism, we successfully obtained a 360° tomography of the inner wall of an intestinal cavity through an FF-OCT system with an LED source. The 10-μm scale resolution enables the early detection of gastrointestinal lesions, which can increase detection rates for esophageal, stomach, or vaginal cancer. All devices used in this system can be integrated by MOEMS technology to contribute to the studies of gastrointestinal medicine and advanced endoscopy technology.

  18. Laser scanning endoscope for diagnostic medicine

    NASA Astrophysics Data System (ADS)

    Ouimette, Donald R.; Nudelman, Sol; Spackman, Thomas; Zaccheo, Scott

    1990-07-01

    A new type of endoscope is being developed which utilizes an optical raster scanning system for imaging through an endoscope. The optical raster scanner utilizes a high speed, multifaceted, rotating polygon mirror system for horizontal deflection, and a slower speed galvanometer driven mirror as the vertical deflection system. When used in combination, the optical raster scanner traces out a raster similar to an electron beam raster used in television systems. This flying spot of light can then be detected by various types of photosensitive detectors to generate a video image of the surface or scene being illuminated by the scanning beam. The optical raster scanner has been coupled to an endoscope. The raster is projected down the endoscope, thereby illuminating the object to be imaged at the distal end of the endoscope. Elemental photodetectors are placed at the distal or proximal end of the endoscope to detect the reflected illumination from the flying spot of light. This time sequenced signal is captured by an image processor for display and processing. This technique offers the possibility for very small diameter endoscopes since illumination channel requirements are eliminated. Using various lasers, very specific spectral selectivity can be achieved to optimum contrast of specific lesions of interest. Using several laser lines, or a white light source, with detectors of specific spectral response, multiple spectrally selected images can be acquired simultaneously. The potential for co-linear therapy delivery while imaging is also possible.

  19. Image segmentation of pyramid style identifier based on Support Vector Machine for colorectal endoscopic images.

    PubMed

    Okamoto, Takumi; Koide, Tetsushi; Sugi, Koki; Shimizu, Tatsuya; Anh-Tuan Hoang; Tamaki, Toru; Raytchev, Bisser; Kaneda, Kazufumi; Kominami, Yoko; Yoshida, Shigeto; Mieno, Hiroshi; Tanaka, Shinji

    2015-08-01

    With the increase of colorectal cancer patients in recent years, the needs of quantitative evaluation of colorectal cancer are increased, and the computer-aided diagnosis (CAD) system which supports doctor's diagnosis is essential. In this paper, a hardware design of type identification module in CAD system for colorectal endoscopic images with narrow band imaging (NBI) magnification is proposed for real-time processing of full high definition image (1920 × 1080 pixel). A pyramid style image segmentation with SVMs for multi-size scan windows, which can be implemented on an FPGA with small circuit area and achieve high accuracy, is proposed for actual complex colorectal endoscopic images.

  20. The use of neuronavigation and intraoperative imaging systems in the surgical treatment of orbital tumors.

    PubMed

    Hodaj, Irgen; Kutlay, Murat; Gonul, Engin; Solmaz, Ilker; Tehli, Ozkan; Temiz, Caglar; Kural, Cahit; Daneyemez, Mehmet K; Izci, Yusuf

    2014-01-01

    We aimed to show the effects of neuronavigation and intraoperative imaging systems on the surgical outcomes of orbital tumors. Seventeen patients who underwent surgical treatment for orbital tumors by transcranial and transnasal approaches between 2008 and 2013 were analyzed retrospectively. Twelve of them were male and 5 were female. The mean age was 41.6 years. Neuronavigation systems were used in all cases. Four patients were operated using intraoperative imaging systems. The transcranial approach was used in 9 (53%) patients, endoscopic medial orbital approach in 4 (23.5%), endoscopic inferolateral approach in 1 (6%), cranioorbitozygomatic approach in 1, lateral approach in 1, and the combined (medial endoscopic and lateral) approach in 1 patients. Total resection was achieved in 5 patients, gross total excision in 2, subtotal in 9 and partial in 1 patients. Modern technology has made a significant contribution to the treatment of orbital tumors. Although technological equipments facilitate the excision of tumors, the level of resection is mainly determined by the nature of tumor and adhesion to the adjacent neurovascular structures. It should not be forgotten that advanced technology never replaces a good anatomical knowledge and surgical experience, but has a complementary role.

  1. Improving the image discontinuous problem by using color temperature mapping method

    NASA Astrophysics Data System (ADS)

    Jeng, Wei-De; Mang, Ou-Yang; Lai, Chien-Cheng; Wu, Hsien-Ming

    2011-09-01

    This article mainly focuses on image processing of radial imaging capsule endoscope (RICE). First, it used the radial imaging capsule endoscope (RICE) to take the images, the experimental used a piggy to get the intestines and captured the images, but the images captured by RICE were blurred due to the RICE has aberration problems in the image center and lower light uniformity affect the image quality. To solve the problems, image processing can use to improve it. Therefore, the images captured by different time can use Person correlation coefficient algorithm to connect all the images, and using the color temperature mapping way to improve the discontinuous problem in the connection region.

  2. Automatic localization of endoscope in intraoperative CT image: A simple approach to augmented reality guidance in laparoscopic surgery.

    PubMed

    Bernhardt, Sylvain; Nicolau, Stéphane A; Agnus, Vincent; Soler, Luc; Doignon, Christophe; Marescaux, Jacques

    2016-05-01

    The use of augmented reality in minimally invasive surgery has been the subject of much research for more than a decade. The endoscopic view of the surgical scene is typically augmented with a 3D model extracted from a preoperative acquisition. However, the organs of interest often present major changes in shape and location because of the pneumoperitoneum and patient displacement. There have been numerous attempts to compensate for this distortion between the pre- and intraoperative states. Some have attempted to recover the visible surface of the organ through image analysis and register it to the preoperative data, but this has proven insufficiently robust and may be problematic with large organs. A second approach is to introduce an intraoperative 3D imaging system as a transition. Hybrid operating rooms are becoming more and more popular, so this seems to be a viable solution, but current techniques require yet another external and constraining piece of apparatus such as an optical tracking system to determine the relationship between the intraoperative images and the endoscopic view. In this article, we propose a new approach to automatically register the reconstruction from an intraoperative CT acquisition with the static endoscopic view, by locating the endoscope tip in the volume data. We first describe our method to localize the endoscope orientation in the intraoperative image using standard image processing algorithms. Secondly, we highlight that the axis of the endoscope needs a specific calibration process to ensure proper registration accuracy. In the last section, we present quantitative and qualitative results proving the feasibility and the clinical potential of our approach. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Averaged subtracted polarization imaging for endoscopic diagnostics of surface microstructures on translucent mucosae

    NASA Astrophysics Data System (ADS)

    Kanamori, Katsuhiro

    2016-07-01

    An endoscopic image processing technique for enhancing the appearance of microstructures on translucent mucosae is described. This technique employs two pairs of co- and cross-polarization images under two different linearly polarized lights, from which the averaged subtracted polarization image (AVSPI) is calculated. Experiments were then conducted using an acrylic phantom and excised porcine stomach tissue using a manual experimental setup with ring-type lighting, two rotating polarizers, and a color camera; better results were achieved with the proposed method than with conventional color intensity image processing. An objective evaluation method that uses texture analysis was developed and used to evaluate the enhanced microstructure images. This paper introduces two types of online, rigid-type, polarimetric endoscopic implementations using a polarized ring-shaped LED and a polarimetric camera. The first type uses a beam-splitter-type color polarimetric camera, and the second uses a single-chip monochrome polarimetric camera. Microstructures on the mucosa surface were enhanced robustly with these online endoscopes regardless of the difference in the extinction ratio of each device. These results show that polarimetric endoscopy using AVSPI is both effective and practical for hardware implementation.

  4. Enhanced differential evolution to combine optical mouse sensor with image structural patches for robust endoscopic navigation.

    PubMed

    Luo, Xiongbiao; Jayarathne, Uditha L; McLeod, A Jonathan; Mori, Kensaku

    2014-01-01

    Endoscopic navigation generally integrates different modalities of sensory information in order to continuously locate an endoscope relative to suspicious tissues in the body during interventions. Current electromagnetic tracking techniques for endoscopic navigation have limited accuracy due to tissue deformation and magnetic field distortion. To avoid these limitations and improve the endoscopic localization accuracy, this paper proposes a new endoscopic navigation framework that uses an optical mouse sensor to measure the endoscope movements along its viewing direction. We then enhance the differential evolution algorithm by modifying its mutation operation. Based on the enhanced differential evolution method, these movement measurements and image structural patches in endoscopic videos are fused to accurately determine the endoscope position. An evaluation on a dynamic phantom demonstrated that our method provides a more accurate navigation framework. Compared to state-of-the-art methods, it improved the navigation accuracy from 2.4 to 1.6 mm and reduced the processing time from 2.8 to 0.9 seconds.

  5. Use of hyperspectral imaging technology to develop a diagnostic support system for gastric cancer

    NASA Astrophysics Data System (ADS)

    Goto, Atsushi; Nishikawa, Jun; Kiyotoki, Shu; Nakamura, Munetaka; Nishimura, Junichi; Okamoto, Takeshi; Ogihara, Hiroyuki; Fujita, Yusuke; Hamamoto, Yoshihiko; Sakaida, Isao

    2015-01-01

    Hyperspectral imaging (HSI) is a new technology that obtains spectroscopic information and renders it in image form. This study examined the difference in the spectral reflectance (SR) of gastric tumors and normal mucosa recorded with a hyperspectral camera equipped with HSI technology and attempted to determine the specific wavelength that is useful for the diagnosis of gastric cancer. A total of 104 gastric tumors removed by endoscopic submucosal dissection from 96 patients at Yamaguchi University Hospital were recorded using a hyperspectral camera. We determined the optimal wavelength and the cut-off value for differentiating tumors from normal mucosa to establish a diagnostic algorithm. We also attempted to highlight tumors by image processing using the hyperspectral camera's analysis software. A wavelength of 770 nm and a cut-off value of 1/4 the corrected SR were selected as the respective optimal wavelength and cut-off values. The rates of sensitivity, specificity, and accuracy of the algorithm's diagnostic capability were 71%, 98%, and 85%, respectively. It was possible to enhance tumors by image processing at the 770-nm wavelength. HSI can be used to measure the SR in gastric tumors and to differentiate between tumorous and normal mucosa.

  6. Rendering-based video-CT registration with physical constraints for image-guided endoscopic sinus surgery

    NASA Astrophysics Data System (ADS)

    Otake, Y.; Leonard, S.; Reiter, A.; Rajan, P.; Siewerdsen, J. H.; Ishii, M.; Taylor, R. H.; Hager, G. D.

    2015-03-01

    We present a system for registering the coordinate frame of an endoscope to pre- or intra- operatively acquired CT data based on optimizing the similarity metric between an endoscopic image and an image predicted via rendering of CT. Our method is robust and semi-automatic because it takes account of physical constraints, specifically, collisions between the endoscope and the anatomy, to initialize and constrain the search. The proposed optimization method is based on a stochastic optimization algorithm that evaluates a large number of similarity metric functions in parallel on a graphics processing unit. Images from a cadaver and a patient were used for evaluation. The registration error was 0.83 mm and 1.97 mm for cadaver and patient images respectively. The average registration time for 60 trials was 4.4 seconds. The patient study demonstrated robustness of the proposed algorithm against a moderate anatomical deformation.

  7. [Study of Image Quality Comparison Based on the MTF Method Between Different Medical Rigid Endoscopes in an In Vitro Model].

    PubMed

    Wang, Yunlong; Ji, Jun; Jiang, Changsong; Huang, Zengyue

    2015-04-01

    This study was aimed to use the method of modulation transfer function (MTF) to compare image quality among three different Olympus medical rigid cystoscopes in an in vitro model. During the experimental processes, we firstly used three different types of cystoscopes (i. e. OLYMPUS cystourethroscopy with FOV of 12 degrees, OLYMPUS Germany A22003A and OLYMPUS A2013A) to collect raster images at different brightness with industrial camera and computer from the resolution target which is with different spatial frequency, and then we processed the collected images using MALAB software with the optical transfer function MTF to obtain the values of MTF at different brightness and different spatial frequency. We then did data mathematical statistics and compared imaging quality. The statistical data showed that all three MTF values were smaller than 1. MTF values with the spatial frequency gradually increasing would decrease approaching 0 at the same brightness. When the brightness enhanced in the same process at the same spatial frequency, MTF values showed a slowly increasing trend. The three endoscopes' MTF values were completely different. In some cases the MTF values had a large difference, and the maximum difference could reach 0.7. Conclusion can be derived from analysis of experimental data that three Olympus medical rigid cystoscopes have completely different imaging quality abilities. The No. 3 endoscope OLYMPUS A2013A has low resolution but high contrast. The No. 1 endoscope OLYMPUS cystourethroscopy with FOV of 12 degrees, on the contrary, had high resolution and lower contrast. The No. 2 endoscope OLYMPUS Germany A22003A had high contrast and high resolution, and its image quality was the best.

  8. Multimodal 3D cancer-mimicking optical phantom

    PubMed Central

    Smith, Gennifer T.; Lurie, Kristen L.; Zlatev, Dimitar V.; Liao, Joseph C.; Ellerbee Bowden, Audrey K.

    2016-01-01

    Three-dimensional (3D) organ-mimicking phantoms provide realistic imaging environments for testing various aspects of optical systems, including for evaluating new probe designs, characterizing the diagnostic potential of new technologies, and assessing novel image processing algorithms prior to validation in real tissue. We introduce and characterize the use of a new material, Dragon Skin (Smooth-On Inc.), and fabrication technique, air-brushing, for fabrication of a 3D phantom that mimics the appearance of a real organ under multiple imaging modalities. We demonstrate the utility of the material and technique by fabricating the first 3D, hollow bladder phantom with realistic normal and multi-stage pathology features suitable for endoscopic detection using the gold standard imaging technique, white light cystoscopy (WLC), as well as the complementary imaging modalities of optical coherence tomography and blue light cystoscopy, which are aimed at improving the sensitivity and specificity of WLC to bladder cancer detection. The flexibility of the material and technique used for phantom construction allowed for the representation of a wide range of diseased tissue states, ranging from inflammation (benign) to high-grade cancerous lesions. Such phantoms can serve as important tools for trainee education and evaluation of new endoscopic instrumentation. PMID:26977369

  9. Novel computer-based endoscopic camera

    NASA Astrophysics Data System (ADS)

    Rabinovitz, R.; Hai, N.; Abraham, Martin D.; Adler, Doron; Nissani, M.; Fridental, Ron; Vitsnudel, Ilia

    1995-05-01

    We have introduced a computer-based endoscopic camera which includes (a) unique real-time digital image processing to optimize image visualization by reducing over exposed glared areas and brightening dark areas, and by accentuating sharpness and fine structures, and (b) patient data documentation and management. The image processing is based on i Sight's iSP1000TM digital video processor chip and Adaptive SensitivityTM patented scheme for capturing and displaying images with wide dynamic range of light, taking into account local neighborhood image conditions and global image statistics. It provides the medical user with the ability to view images under difficult lighting conditions, without losing details `in the dark' or in completely saturated areas. The patient data documentation and management allows storage of images (approximately 1 MB per image for a full 24 bit color image) to any storage device installed into the camera, or to an external host media via network. The patient data which is included with every image described essential information on the patient and procedure. The operator can assign custom data descriptors, and can search for the stored image/data by typing any image descriptor. The camera optics has extended zoom range of f equals 20 - 45 mm allowing control of the diameter of the field which is displayed on the monitor such that the complete field of view of the endoscope can be displayed on all the area of the screen. All these features provide versatile endoscopic camera with excellent image quality and documentation capabilities.

  10. New method for detection of gastric cancer by hyperspectral imaging: a pilot study

    NASA Astrophysics Data System (ADS)

    Kiyotoki, Shu; Nishikawa, Jun; Okamoto, Takeshi; Hamabe, Kouichi; Saito, Mari; Goto, Atsushi; Fujita, Yusuke; Hamamoto, Yoshihiko; Takeuchi, Yusuke; Satori, Shin; Sakaida, Isao

    2013-02-01

    We developed a new, easy, and objective method to detect gastric cancer using hyperspectral imaging (HSI) technology combining spectroscopy and imaging A total of 16 gastroduodenal tumors removed by endoscopic resection or surgery from 14 patients at Yamaguchi University Hospital, Japan, were recorded using a hyperspectral camera (HSC) equipped with HSI technology Corrected spectral reflectance was obtained from 10 samples of normal mucosa and 10 samples of tumors for each case The 16 cases were divided into eight training cases (160 training samples) and eight test cases (160 test samples) We established a diagnostic algorithm with training samples and evaluated it with test samples Diagnostic capability of the algorithm for each tumor was validated, and enhancement of tumors by image processing using the HSC was evaluated The diagnostic algorithm used the 726-nm wavelength, with a cutoff point established from training samples The sensitivity, specificity, and accuracy rates of the algorithm's diagnostic capability in the test samples were 78.8% (63/80), 92.5% (74/80), and 85.6% (137/160), respectively Tumors in HSC images of 13 (81.3%) cases were well enhanced by image processing Differences in spectral reflectance between tumors and normal mucosa suggested that tumors can be clearly distinguished from background mucosa with HSI technology.

  11. A hands-free region-of-interest selection interface for solo surgery with a wide-angle endoscope: preclinical proof of concept.

    PubMed

    Jung, Kyunghwa; Choi, Hyunseok; Hong, Hanpyo; Adikrishna, Arnold; Jeon, In-Ho; Hong, Jaesung

    2017-02-01

    A hands-free region-of-interest (ROI) selection interface is proposed for solo surgery using a wide-angle endoscope. A wide-angle endoscope provides images with a larger field of view than a conventional endoscope. With an appropriate selection interface for a ROI, surgeons can also obtain a detailed local view as if they moved a conventional endoscope in a specific position and direction. To manipulate the endoscope without releasing the surgical instrument in hand, a mini-camera is attached to the instrument, and the images taken by the attached camera are analyzed. When a surgeon moves the instrument, the instrument orientation is calculated by an image processing. Surgeons can select the ROI with this instrument movement after switching from 'task mode' to 'selection mode.' The accelerated KAZE algorithm is used to track the features of the camera images once the instrument is moved. Both the wide-angle and detailed local views are displayed simultaneously, and a surgeon can move the local view area by moving the mini-camera attached to the surgical instrument. Local view selection for a solo surgery was performed without releasing the instrument. The accuracy of camera pose estimation was not significantly different between camera resolutions, but it was significantly different between background camera images with different numbers of features (P < 0.01). The success rate of ROI selection diminished as the number of separated regions increased. However, separated regions up to 12 with a region size of 160 × 160 pixels were selected with no failure. Surgical tasks on a phantom model and a cadaver were attempted to verify the feasibility in a clinical environment. Hands-free endoscope manipulation without releasing the instruments in hand was achieved. The proposed method requires only a small, low-cost camera and an image processing. The technique enables surgeons to perform solo surgeries without a camera assistant.

  12. Classification of endoscopic capsule images by using color wavelet features, higher order statistics and radial basis functions.

    PubMed

    Lima, C S; Barbosa, D; Ramos, J; Tavares, A; Monteiro, L; Carvalho, L

    2008-01-01

    This paper presents a system to support medical diagnosis and detection of abnormal lesions by processing capsule endoscopic images. Endoscopic images possess rich information expressed by texture. Texture information can be efficiently extracted from medium scales of the wavelet transform. The set of features proposed in this paper to code textural information is named color wavelet covariance (CWC). CWC coefficients are based on the covariances of second order textural measures, an optimum subset of them is proposed. Third and forth order moments are added to cope with distributions that tend to become non-Gaussian, especially in some pathological cases. The proposed approach is supported by a classifier based on radial basis functions procedure for the characterization of the image regions along the video frames. The whole methodology has been applied on real data containing 6 full endoscopic exams and reached 95% specificity and 93% sensitivity.

  13. Single lens system for forward-viewing navigation and scanning side-viewing optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Tate, Tyler H.; McGregor, Davis; Barton, Jennifer K.

    2017-02-01

    The optical design for a dual modality endoscope based on piezo scanning fiber technology is presented including a novel technique to combine forward-viewing navigation and side viewing OCT. Potential applications include navigating body lumens such as the fallopian tube, biliary ducts and cardiovascular system. A custom cover plate provides a rotationally symmetric double reflection of the OCT beam to deviate and focus the OCT beam out the side of the endoscope for cross-sectional imaging of the tubal lumen. Considerations in the choice of the scanning fiber are explored and a new technique to increase the divergence angle of the scanning fiber to improve system performance is presented. Resolution and the necessary scanning density requirements to achieve Nyquist sampling of the full image are considered. The novel optical design lays the groundwork for a new approach integrating side-viewing OCT into multimodality endoscopes for small lumen imaging. KEYWORDS:

  14. Feasibility of Newly Developed Endoscopic Ultrasound with Zone Sonography Technology for Diagnosis of Pancreatic Diseases

    PubMed Central

    Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2013-01-01

    Background/Aims To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonography™ technology (ZST; Fujifilm Corp.). Methods Seventy-five patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts. The endoscopes used were EG-530UR2 and EG-530UT2 (Fujifilm Corp.). Two items were evaluated: visualization depth among four frequencies and image quality after automatic adjustment of sound speed (AASS), assessed using a 5-scale Likert scale by two endosonographers blinded to disease status. Because sound speed could be manually controlled, besides AASS, image quality at sound speeds of 1,440 and 1,600 m/sec were also assessed. Results In all cases, sufficient images were obtained in the range of 3 cm from the EUS probe. Judgments of image quality before AASS were 3.49±0.50, 3.65±0.48, respectively. After AASS, A and B scored 4.36±0.48 and 4.40±0.49 (p<0.0001). There were significant differences in the data before and after AASS and plus 60 m/sec, but no significant difference between the datasets were seen after AASS and at sound speeds manually set for minus 100 m/sec. Conclusions EUS with ZST was shown to be feasible in this preliminary experiment. Further evaluation of this novel technology is necessary and awaited. PMID:23898392

  15. Feasibility of newly developed endoscopic ultrasound with zone sonography technology for diagnosis of pancreatic diseases.

    PubMed

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2013-07-01

    To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonography™ technology (ZST; Fujifilm Corp.). Seventy-five patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts. The endoscopes used were EG-530UR2 and EG-530UT2 (Fujifilm Corp.). Two items were evaluated: visualization depth among four frequencies and image quality after automatic adjustment of sound speed (AASS), assessed using a 5-scale Likert scale by two endosonographers blinded to disease status. Because sound speed could be manually controlled, besides AASS, image quality at sound speeds of 1,440 and 1,600 m/sec were also assessed. In all cases, sufficient images were obtained in the range of 3 cm from the EUS probe. Judgments of image quality before AASS were 3.49±0.50, 3.65±0.48, respectively. After AASS, A and B scored 4.36±0.48 and 4.40±0.49 (p<0.0001). There were significant differences in the data before and after AASS and plus 60 m/sec, but no significant difference between the datasets were seen after AASS and at sound speeds manually set for minus 100 m/sec. EUS with ZST was shown to be feasible in this preliminary experiment. Further evaluation of this novel technology is necessary and awaited.

  16. Intravital endoscopic technology for real-time monitoring of inflammation caused in experimental periodontitis.

    PubMed

    Movila, Alexandru; Kajiya, Mikihito; Wisitrasameewong, Wichaya; Stashenko, Philip; Vardar-Sengul, Saynur; Hernandez, Maria; Thomas Temple, H; Kawai, Toshihisa

    2018-06-01

    We report a novel method for in situ imaging of microvascular permeability in inflamed gingival tissue, using state-of-the-art Cellvizio™ intravital endoscopic technology and a mouse model of ligature-induced periodontitis. The silk ligature was first placed at the upper left second molar. Seven days later, the ligature was removed, and the animals were intravenously injected with Evans blue. Evans blue dye, which selectively binds to blood albumin, was used to monitor the level of inflammation by monitoring vascular permeability in control non-diseased and ligature-induced experimental periodontitis tissue. More specifically, leakage of Evans blue-bound albumin from the micro-capillary to connective tissue indicates the state of inflammation occurring in the specific site. Evans blue leakage from blood vessels was imaged in situ by directly attaching the endoscope (mini Z tip) of the Cellvizio™ system to the gingival tissue without any surgical incision. Evans blue emission intensity was significantly elevated in gingiva of periodontitis lesions, but not control non-ligature placed gingiva, indicating that this technology can be used as a potential minimally invasive diagnostic tool to monitor the level of inflammation at the periodontal disease site. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Broadband rotary joint for high speed ultrahigh resolution endoscopic OCT imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Alemohammad, Milad; Yuan, Wu; Mavadia-Shukla, Jessica; Liang, Wenxuan; Yu, Xiaoyun; Yu, Shaoyong; Li, Xingde

    2016-03-01

    Endoscopic OCT is a promising technology enabling noninvasive in vivo imaging of internal organs, such as the gastrointestinal tract and airways. The past few years have witnessed continued efforts to achieve ultrahigh resolution and speed. It is well-known that the axial resolution in OCT imaging has a quadratic dependence on the central wavelength. While conventional OCT endoscopes operate in 1300 nm wavelength, the second-generation endoscopes are designed for operation around 800 nm where turn-key, broadband sources are becoming readily available. Traditionally 1300 nm OCT endoscopes are scanned at the proximal end, and a broadband fiber-optic rotary joint as a key component in scanning endoscopic OCT is commercially available. Bandwidths in commercial 800 nm rotary joints are unfortunately compromised due to severe chromatic aberration, which limits the resolution afforded by the broadband light source. In the past we remedied this limitation by using a home-made capillary-tube-based rotary joint where the maximum reliable speed is ~10 revolutions/second. In this submission we report our second-generation, home-built high-speed and broadband rotary joint for 800 nm wavelength, which uses achromatic doublets in order achieve broadband achromatic operation. The measured one-way throughput of the rotary joint is >67 % while the fluctuation of the double-pass coupling efficiency during 360° rotation is less than +/-5 % at a speed of 70 revolutions/second. We demonstrate the operation of this rotary joint in conjunction with our ultrahigh-resolution (2.4 µm in air) diffractive catheter by three-dimensional full-circumferential endoscopic imaging of guinea pig esophagus at 70 frames per second in vivo.

  18. Endoscopic hyperspectral imaging: light guide optimization for spectral light source

    NASA Astrophysics Data System (ADS)

    Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.

    2018-02-01

    Hyperspectral imaging (HSI) is a technology used in remote sensing, food processing and documentation recovery. Recently, this approach has been applied in the medical field to spectrally interrogate regions of interest within respective substrates. In spectral imaging, a two (spatial) dimensional image is collected, at many different (spectral) wavelengths, to sample spectral signatures from different regions and/or components within a sample. Here, we report on the use of hyperspectral imaging for endoscopic applications. Colorectal cancer is the 3rd leading cancer for incidences and deaths in the US. One factor of severity is the miss rate of precancerous/flat lesions ( 65% accuracy). Integrating HSI into colonoscopy procedures could minimize misdiagnosis and unnecessary resections. We have previously reported a working prototype light source with 16 high-powered light emitting diodes (LEDs) capable of high speed cycling and imaging. In recent testing, we have found our current prototype is limited by transmission loss ( 99%) through the multi-furcated solid light guide (lightpipe) and the desired framerate (20-30 fps) could not be achieved. Here, we report on a series of experimental and modeling studies to better optimize the lightpipe and the spectral endoscopy system as a whole. The lightpipe was experimentally evaluated using an integrating sphere and spectrometer (Ocean Optics). Modeling the lightpipe was performed using Monte Carlo optical ray tracing in TracePro (Lambda Research Corp.). Results of these optimization studies will aid in manufacturing a revised prototype with the newly designed light guide and increased sensitivity. Once the desired optical output (5-10 mW) is achieved then the HIS endoscope system will be able to be implemented without adding onto the procedure time.

  19. Panorama imaging for image-to-physical registration of narrow drill holes inside spongy bones

    NASA Astrophysics Data System (ADS)

    Bergmeier, Jan; Fast, Jacob Friedemann; Ortmaier, Tobias; Kahrs, Lüder Alexander

    2017-03-01

    Image-to-physical registration based on volumetric data like computed tomography on the one side and intraoperative endoscopic images on the other side is an important method for various surgical applications. In this contribution, we present methods to generate panoramic views from endoscopic recordings for image-to-physical registration of narrow drill holes inside spongy bone. One core application is the registration of drill poses inside the mastoid during minimally invasive cochlear implantations. Besides the development of image processing software for registration, investigations are performed on a miniaturized optical system, achieving 360° radial imaging with one shot by extending a conventional, small, rigid, rod lens endoscope. A reflective cone geometry is used to deflect radially incoming light rays into the endoscope optics. Therefore, a cone mirror is mounted in front of a conventional 0° endoscope. Furthermore, panoramic images of inner drill hole surfaces in artificial bone material are created. Prior to drilling, cone beam computed tomography data is acquired from this artificial bone and simulated endoscopic views are generated from this data. A qualitative and quantitative image comparison of resulting views in terms of image-to-image registration is performed. First results show that downsizing of panoramic optics to a diameter of 3mm is possible. Conventional rigid rod lens endoscopes can be extended to produce suitable panoramic one-shot image data. Using unrolling and stitching methods, images of the inner drill hole surface similar to computed tomography image data of the same surface were created. Registration is performed on ten perturbations of the search space and results in target registration errors of (0:487 +/- 0:438)mm at the entry point and (0:957 +/- 0:948)mm at the exit as well as an angular error of (1:763 +/- 1:536)°. The results show suitability of this image data for image-to-image registration. Analysis of the error components in different directions reveals a strong influence of the pattern structure, meaning higher diversity results into smaller errors.

  20. Informative-frame filtering in endoscopy videos

    NASA Astrophysics Data System (ADS)

    An, Yong Hwan; Hwang, Sae; Oh, JungHwan; Lee, JeongKyu; Tavanapong, Wallapak; de Groen, Piet C.; Wong, Johnny

    2005-04-01

    Advances in video technology are being incorporated into today"s healthcare practice. For example, colonoscopy is an important screening tool for colorectal cancer. Colonoscopy allows for the inspection of the entire colon and provides the ability to perform a number of therapeutic operations during a single procedure. During a colonoscopic procedure, a tiny video camera at the tip of the endoscope generates a video signal of the internal mucosa of the colon. The video data are displayed on a monitor for real-time analysis by the endoscopist. Other endoscopic procedures include upper gastrointestinal endoscopy, enteroscopy, bronchoscopy, cystoscopy, and laparoscopy. However, a significant number of out-of-focus frames are included in this type of videos since current endoscopes are equipped with a single, wide-angle lens that cannot be focused. The out-of-focus frames do not hold any useful information. To reduce the burdens of the further processes such as computer-aided image processing or human expert"s examinations, these frames need to be removed. We call an out-of-focus frame as non-informative frame and an in-focus frame as informative frame. We propose a new technique to classify the video frames into two classes, informative and non-informative frames using a combination of Discrete Fourier Transform (DFT), Texture Analysis, and K-Means Clustering. The proposed technique can evaluate the frames without any reference image, and does not need any predefined threshold value. Our experimental studies indicate that it achieves over 96% of four different performance metrics (i.e. precision, sensitivity, specificity, and accuracy).

  1. Cascaded deep decision networks for classification of endoscopic images

    NASA Astrophysics Data System (ADS)

    Murthy, Venkatesh N.; Singh, Vivek; Sun, Shanhui; Bhattacharya, Subhabrata; Chen, Terrence; Comaniciu, Dorin

    2017-02-01

    Both traditional and wireless capsule endoscopes can generate tens of thousands of images for each patient. It is desirable to have the majority of irrelevant images filtered out by automatic algorithms during an offline review process or to have automatic indication for highly suspicious areas during an online guidance. This also applies to the newly invented endomicroscopy, where online indication of tumor classification plays a significant role. Image classification is a standard pattern recognition problem and is well studied in the literature. However, performance on the challenging endoscopic images still has room for improvement. In this paper, we present a novel Cascaded Deep Decision Network (CDDN) to improve image classification performance over standard Deep neural network based methods. During the learning phase, CDDN automatically builds a network which discards samples that are classified with high confidence scores by a previously trained network and concentrates only on the challenging samples which would be handled by the subsequent expert shallow networks. We validate CDDN using two different types of endoscopic imaging, which includes a polyp classification dataset and a tumor classification dataset. From both datasets we show that CDDN can outperform other methods by about 10%. In addition, CDDN can also be applied to other image classification problems.

  2. A portable high-definition electronic endoscope based on embedded system

    NASA Astrophysics Data System (ADS)

    Xu, Guang; Wang, Liqiang; Xu, Jin

    2012-11-01

    This paper presents a low power and portable highdefinition (HD) electronic endoscope based on CortexA8 embedded system. A 1/6 inch CMOS image sensor is used to acquire HD images with 1280 *800 pixels. The camera interface of A8 is designed to support images of various sizes and support multiple inputs of video format such as ITUR BT601/ 656 standard. Image rotation (90 degrees clockwise) and image process functions are achieved by CAMIF. The decode engine of the processor plays back or records HD videos at speed of 30 frames per second, builtin HDMI interface transmits high definition images to the external display. Image processing procedures such as demosaicking, color correction and auto white balance are realized on the A8 platform. Other functions are selected through OSD settings. An LCD panel displays the real time images. The snapshot pictures or compressed videos are saved in an SD card or transmited to a computer through USB interface. The size of the camera head is 4×4.8×15 mm with more than 3 meters working distance. The whole endoscope system can be powered by a lithium battery, with the advantages of miniature, low cost and portability.

  3. The Past, Present, and Future of Image-Enhanced Endoscopy

    PubMed Central

    Jang, Jae-Young

    2015-01-01

    Despite the remarkable progress recently made to enhance the resolution of white-light endoscopy, detection, and diagnosis of premalignant lesions, such as adenomas and subtle early-stage cancers, remains a great challenge. As for example, although chromoendoscopy, such as endoscopy using indigo carmine, is useful for the early diagnosis of subtle lesions, the technique presents various disadvantages ranging from the time required for spray application of the dye and suctioning of excess dye to the increased difficulty in identifying lesions in the presence of severe inflammation and obstruction of visual field due to the pooling of solution in depressed-type lesions. To overcome these diagnostic problems associated with chromoendoscopy, research has focused on the development of endoscopes based on new optical technologies. Several types of image-enhanced endoscopy methods have recently been presented. In particular, image-enhanced endoscopy has emerged as a new paradigm for the diagnosis of gastrointestinal disorders. Image-enhanced endoscopes provide high-contrast images of lesions by means of optical or electronic technologies, including the contrast enhancement of the mucosal surface and of blood vessels. Chromoendoscopy, narrow-band imaging, i-SCAN, and flexible spectral imaging color enhancement are representative examples of image-enhanced endoscopy discussed in this paper. PMID:26668791

  4. Augmented reality image guidance for minimally invasive coronary artery bypass

    NASA Astrophysics Data System (ADS)

    Figl, Michael; Rueckert, Daniel; Hawkes, David; Casula, Roberto; Hu, Mingxing; Pedro, Ose; Zhang, Dong Ping; Penney, Graeme; Bello, Fernando; Edwards, Philip

    2008-03-01

    We propose a novel system for image guidance in totally endoscopic coronary artery bypass (TECAB). A key requirement is the availability of 2D-3D registration techniques that can deal with non-rigid motion and deformation. Image guidance for TECAB is mainly required before the mechanical stabilization of the heart, thus the most dominant source of non-rigid deformation is the motion of the beating heart. To augment the images in the endoscope of the da Vinci robot, we have to find the transformation from the coordinate system of the preoperative imaging modality to the system of the endoscopic cameras. In a first step we build a 4D motion model of the beating heart. Intraoperatively we can use the ECG or video processing to determine the phase of the cardiac cycle. We can then take the heart surface from the motion model and register it to the stereo-endoscopic images of the da Vinci robot using 2D-3D registration methods. We are investigating robust feature tracking and intensity-based methods for this purpose. Images of the vessels available in the preoperative coordinate system can then be transformed to the camera system and projected into the calibrated endoscope view using two video mixers with chroma keying. It is hoped that the augmented view can improve the efficiency of TECAB surgery and reduce the conversion rate to more conventional procedures.

  5. Confocal laser endomicroscopy in the "in vivo" histological diagnosis of the gastrointestinal tract.

    PubMed

    De Palma, Giovanni D

    2009-12-14

    Recent technological advances in miniaturization have allowed for a confocal scanning microscope to be integrated into a conventional flexible endoscope, or into trans-endoscopic probes, a technique now known as confocal endomicroscopy or confocal laser endomicroscopy. This newly-developed technology has enabled endoscopists to collect real-time in vivo histological images or "virtual biopsies" of the gastrointestinal mucosa during endoscopy, and has stimulated significant interest in the application of this technique in clinical gastroenterology. This review aims to evaluate the current data on the technical aspects and the utility of this new technology in clinical gastroenterology and its potential impact in the future, particularly in the screening or surveillance of gastrointestinal neoplasia.

  6. Image stitching and image reconstruction of intestines captured using radial imaging capsule endoscope

    NASA Astrophysics Data System (ADS)

    Ou-Yang, Mang; Jeng, Wei-De; Wu, Yin-Yi; Dung, Lan-Rong; Wu, Hsien-Ming; Weng, Ping-Kuo; Huang, Ker-Jer; Chiu, Luan-Jiau

    2012-05-01

    This study investigates image processing using the radial imaging capsule endoscope (RICE) system. First, an experimental environment is established in which a simulated object has a shape that is similar to a cylinder, such that a triaxial platform can be used to push the RICE into the sample and capture radial images. Then four algorithms (mean absolute error, mean square error, Pearson correlation coefficient, and deformation processing) are used to stitch the images together. The Pearson correlation coefficient method is the most effective algorithm because it yields the highest peak signal-to-noise ratio, higher than 80.69 compared to the original image. Furthermore, a living animal experiment is carried out. Finally, the Pearson correlation coefficient method and vector deformation processing are used to stitch the images that were captured in the living animal experiment. This method is very attractive because unlike the other methods, in which two lenses are required to reconstruct the geometrical image, RICE uses only one lens and one mirror.

  7. Modelling of a laser-pumped light source for endoscopic surgery

    NASA Astrophysics Data System (ADS)

    Nadeau, Valerie J.; Elson, Daniel S.; Hanna, George B.; Neil, Mark A. A.

    2008-09-01

    A white light source, based on illumination of a yellow phosphor with a fibre-coupled blue-violet diode laser, has been designed and built for use in endoscopic surgery. This narrow light probe can be integrated into a standard laparoscope or inserted into the patient separately via a needle. We present a Monte Carlo model of light scattering and phosphorescence within the phosphor/silicone matrix at the probe tip, and measurements of the colour, intensity, and uniformity of the illumination. Images obtained under illumination with this light source are also presented, demonstrating the improvement in illumination quality over existing endoscopic light sources. This new approach to endoscopic lighting has the advantages of compact design, improved ergonomics, and more uniform illumination in comparison with current technologies.

  8. The Steris Reliance EPS endoscope processing system: a new automated endoscope reprocessing technology.

    PubMed

    2007-01-01

    In this Evaluation, we examine whether the Steris Reliance EPS--a flexible endoscope reprocessing system that was recently introduced to the U.S. market--offers meaningful advantages over "traditional" automated endoscope reprocessors (AERs). Most AERs on the market function similarly to one another. The Reliance EPS, however, includes some unique features that distinguish it from other AERs. For example, it incorporates a "boot" technology for loading the endoscopes into the unit without requiring a lot of endoscope-specific connectors, and it dispenses the germicide used to disinfect the endoscopes from a single-use container. This Evaluation looks at whether the unique features of this model make it a better choice than traditional AERs for reprocessing flexible endoscopes. Our study focuses on whether the Reliance EPS is any more likely to be used correctly-thereby reducing the likelihood that an endoscope will be reprocessed inadequately-and whether the unit possesses any design flaws that could lead to reprocessing failures. We detail the unit's advantages and disadvantages compared with other AERs, and we describe what current users have to say. Our conclusions will help facilities determine whether to select the Reliance EPS.

  9. Endoscopic spectral-domain polarization-sensitive optical coherence tomography system

    NASA Astrophysics Data System (ADS)

    Wang, Yi; Chen, Xiaodong; Hu, Zhiqiang; Li, Qiao; Yu, Daoyin

    2008-02-01

    In this paper, we introduced a fiber-based endoscopic Spectral-domain Polarization-sensitive OCT (SD-PS-OCT) experimental scheme for detecting the internal organ disease, which is based on low-coherence interferometer and two spectrometers. The SD-PS-OCT has the advantages of both Spectral-domain OCT (SD-OCT) and Polarization-sensitive OCT (PS-OCT). It is able to get the real-time image of reflectivity and birefringence distribution of tissue at the same time. The usage of SD-PS-OCT in endoscopic diagnosing system provides it the possibility to detect the internal organ disease. Since SD-PS-OCT can image the pathological changes of biological tissue below surface (1-3mm) with high resolution (1-15μm), it is able to help diagnosing early diseases of internal organs, which makes it a biomedical technology with bright future.

  10. Fibre-optic nonlinear optical microscopy and endoscopy.

    PubMed

    Fu, L; Gu, M

    2007-06-01

    Nonlinear optical microscopy has been an indispensable laboratory tool of high-resolution imaging in thick tissue and live animals. Rapid developments of fibre-optic components in terms of growing functionality and decreasing size provide enormous opportunities for innovations in nonlinear optical microscopy. Fibre-based nonlinear optical endoscopy is the sole instrumentation to permit the cellular imaging within hollow tissue tracts or solid organs that are inaccessible to a conventional optical microscope. This article reviews the current development of fibre-optic nonlinear optical microscopy and endoscopy, which includes crucial technologies for miniaturized nonlinear optical microscopy and their embodiments of endoscopic systems. A particular attention is given to several classes of photonic crystal fibres that have been applied to nonlinear optical microscopy due to their unique properties for ultrashort pulse delivery and signal collection. Furthermore, fibre-optic nonlinear optical imaging systems can be classified into portable microscopes suitable for imaging behaving animals, rigid endoscopes that allow for deep tissue imaging with minimally invasive manners, and flexible endoscopes enabling imaging of internal organs. Fibre-optic nonlinear optical endoscopy is coming of age and a paradigm shift leading to optical microscope tools for early cancer detection and minimally invasive surgery.

  11. Real-time tracking and virtual endoscopy in cone-beam CT-guided surgery of the sinuses and skull base in a cadaver model.

    PubMed

    Prisman, Eitan; Daly, Michael J; Chan, Harley; Siewerdsen, Jeffrey H; Vescan, Allan; Irish, Jonathan C

    2011-01-01

    Custom software was developed to integrate intraoperative cone-beam computed tomography (CBCT) images with endoscopic video for surgical navigation and guidance. A cadaveric head was used to assess the accuracy and potential clinical utility of the following functionality: (1) real-time tracking of the endoscope in intraoperative 3-dimensional (3D) CBCT; (2) projecting an orthogonal reconstructed CBCT image, at or beyond the endoscope, which is parallel to the tip of the endoscope corresponding to the surgical plane; (3) virtual reality fusion of endoscopic video and 3D CBCT surface rendering; and (4) overlay of preoperatively defined contours of anatomical structures of interest. Anatomical landmarks were contoured in CBCT of a cadaveric head. An experienced endoscopic surgeon was oriented to the software and asked to rate the utility of the navigation software in carrying out predefined surgical tasks. Utility was evaluated using a rating scale for: (1) safely completing the task; and (2) potential for surgical training. Surgical tasks included: (1) uncinectomy; (2) ethmoidectomy; (3) sphenoidectomy/pituitary resection; and (4) clival resection. CBCT images were updated following each ablative task. As a teaching tool, the software was evaluated as "very useful" for all surgical tasks. Regarding safety and task completion, the software was evaluated as "no advantage" for task (1), "minimal" for task (2), and "very useful" for tasks (3) and (4). Landmark identification for structures behind bone was "very useful" for both categories. The software increased surgical confidence in safely completing challenging ablative tasks by presenting real-time image guidance for highly complex ablative procedures. In addition, such technology offers a valuable teaching aid to surgeons in training. Copyright © 2011 American Rhinologic Society-American Academy of Otolaryngic Allergy, LLC.

  12. Endoscopic laser range scanner for minimally invasive, image guided kidney surgery

    NASA Astrophysics Data System (ADS)

    Friets, Eric; Bieszczad, Jerry; Kynor, David; Norris, James; Davis, Brynmor; Allen, Lindsay; Chambers, Robert; Wolf, Jacob; Glisson, Courtenay; Herrell, S. Duke; Galloway, Robert L.

    2013-03-01

    Image guided surgery (IGS) has led to significant advances in surgical procedures and outcomes. Endoscopic IGS is hindered, however, by the lack of suitable intraoperative scanning technology for registration with preoperative tomographic image data. This paper describes implementation of an endoscopic laser range scanner (eLRS) system for accurate, intraoperative mapping of the kidney surface, registration of the measured kidney surface with preoperative tomographic images, and interactive image-based surgical guidance for subsurface lesion targeting. The eLRS comprises a standard stereo endoscope coupled to a steerable laser, which scans a laser fan beam across the kidney surface, and a high-speed color camera, which records the laser-illuminated pixel locations on the kidney. Through calibrated triangulation, a dense set of 3-D surface coordinates are determined. At maximum resolution, the eLRS acquires over 300,000 surface points in less than 15 seconds. Lower resolution scans of 27,500 points are acquired in one second. Measurement accuracy of the eLRS, determined through scanning of reference planar and spherical phantoms, is estimated to be 0.38 +/- 0.27 mm at a range of 2 to 6 cm. Registration of the scanned kidney surface with preoperative image data is achieved using a modified iterative closest point algorithm. Surgical guidance is provided through graphical overlay of the boundaries of subsurface lesions, vasculature, ducts, and other renal structures labeled in the CT or MR images, onto the eLRS camera image. Depth to these subsurface targets is also displayed. Proof of clinical feasibility has been established in an explanted perfused porcine kidney experiment.

  13. Minimally invasive multimode optical fiber microendoscope for deep brain fluorescence imaging

    PubMed Central

    Ohayon, Shay; Caravaca-Aguirre, Antonio; Piestun, Rafael; DiCarlo, James J.

    2018-01-01

    A major open challenge in neuroscience is the ability to measure and perturb neural activity in vivo from well defined neural sub-populations at cellular resolution anywhere in the brain. However, limitations posed by scattering and absorption prohibit non-invasive multi-photon approaches for deep (>2mm) structures, while gradient refractive index (GRIN) endoscopes are relatively thick and can cause significant damage upon insertion. Here, we present a novel micro-endoscope design to image neural activity at arbitrary depths via an ultra-thin multi-mode optical fiber (MMF) probe that has 5–10X thinner diameter than commercially available micro-endoscopes. We demonstrate micron-scale resolution, multi-spectral and volumetric imaging. In contrast to previous approaches, we show that this method has an improved acquisition speed that is sufficient to capture rapid neuronal dynamics in-vivo in rodents expressing a genetically encoded calcium indicator (GCaMP). Our results emphasize the potential of this technology in neuroscience applications and open up possibilities for cellular resolution imaging in previously unreachable brain regions. PMID:29675297

  14. Implementation of real-time digital endoscopic image processing system

    NASA Astrophysics Data System (ADS)

    Song, Chul Gyu; Lee, Young Mook; Lee, Sang Min; Kim, Won Ky; Lee, Jae Ho; Lee, Myoung Ho

    1997-10-01

    Endoscopy has become a crucial diagnostic and therapeutic procedure in clinical areas. Over the past four years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholecystectomy, pelviscopic endometriosis, and surgical arthroscopy. In this study, we developed a computer system, which is composed of a frame grabber, a sound board, a VCR control board, a LAN card and EDMS. Also, computer system controls peripheral instruments such as a color video printer, a video cassette recorder, and endoscopic input/output signals. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards; namely Microsoft Windows as an operating system, TCP/IP as a network protocol and a time sequential database that handles both images and speech. For the purpose of data storage, we used MOD and CD- R. Digital endoscopic system was designed to be able to store, recreate, change, and compress signals and medical images. Computerized endoscopy enables us to generate and manipulate the original visual document, making it accessible to a virtually unlimited number of physicians.

  15. Smartphone-Based Endoscope System for Advanced Point-of-Care Diagnostics: Feasibility Study

    PubMed Central

    Bae, Jung Kweon; Vavilin, Andrey; You, Joon S; Kim, Hyeongeun; Ryu, Seon Young; Jang, Jeong Hun

    2017-01-01

    Background Endoscopic technique is often applied for the diagnosis of diseases affecting internal organs and image-guidance of surgical procedures. Although the endoscope has become an indispensable tool in the clinic, its utility has been limited to medical offices or operating rooms because of the large size of its ancillary devices. In addition, the basic design and imaging capability of the system have remained relatively unchanged for decades. Objective The objective of this study was to develop a smartphone-based endoscope system capable of advanced endoscopic functionalities in a compact size and at an affordable cost and to demonstrate its feasibility of point-of-care through human subject imaging. Methods We developed and designed to set up a smartphone-based endoscope system, incorporating a portable light source, relay-lens, custom adapter, and homebuilt Android app. We attached three different types of existing rigid or flexible endoscopic probes to our system and captured the endoscopic images using the homebuilt app. Both smartphone-based endoscope system and commercialized clinical endoscope system were utilized to compare the imaging quality and performance. Connecting the head-mounted display (HMD) wirelessly, the smartphone-based endoscope system could superimpose an endoscopic image to real-world view. Results A total of 15 volunteers who were accepted into our study were captured using our smartphone-based endoscope system, as well as the commercialized clinical endoscope system. It was found that the imaging performance of our device had acceptable quality compared with that of the conventional endoscope system in the clinical setting. In addition, images captured from the HMD used in the smartphone-based endoscope system improved eye-hand coordination between the manipulating site and the smartphone screen, which in turn reduced spatial disorientation. Conclusions The performance of our endoscope system was evaluated against a commercial system in routine otolaryngology examinations. We also demonstrated and evaluated the feasibility of conducting endoscopic procedures through a custom HMD. PMID:28751302

  16. Stereo Imaging Miniature Endoscope with Single Imaging Chip and Conjugated Multi-Bandpass Filters

    NASA Technical Reports Server (NTRS)

    Shahinian, Hrayr Karnig (Inventor); Bae, Youngsam (Inventor); White, Victor E. (Inventor); Shcheglov, Kirill V. (Inventor); Manohara, Harish M. (Inventor); Kowalczyk, Robert S. (Inventor)

    2018-01-01

    A dual objective endoscope for insertion into a cavity of a body for providing a stereoscopic image of a region of interest inside of the body including an imaging device at the distal end for obtaining optical images of the region of interest (ROI), and processing the optical images for forming video signals for wired and/or wireless transmission and display of 3D images on a rendering device. The imaging device includes a focal plane detector array (FPA) for obtaining the optical images of the ROI, and processing circuits behind the FPA. The processing circuits convert the optical images into the video signals. The imaging device includes right and left pupil for receiving a right and left images through a right and left conjugated multi-band pass filters. Illuminators illuminate the ROI through a multi-band pass filter having three right and three left pass bands that are matched to the right and left conjugated multi-band pass filters. A full color image is collected after three or six sequential illuminations with the red, green and blue lights.

  17. Endoscopic OCT for in-vivo imaging of precancer and cancer states of human mucosa

    NASA Astrophysics Data System (ADS)

    Sergeev, Alexander M.; Gelikonov, Valentin M.; Gelikonov, Grigory V.; Feldchtein, Felix I.; Kuranov, Roman V.; Gladkova, Natalia D.; Shakhova, Natalia M.; Kuznetzova, Irina N.; Snopova, Ludmila; Denisenko, Arkady; Almasov, Valentin

    1998-01-01

    First results of endoscopic applications of optical coherence tomography for in vivo studies of human mucosa in gastrointestinal and genital tracts are presented. A novel endoscopic OCT system has ben created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, stomach and uterine cervix as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancerous tissue is distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  18. Geometric estimation of intestinal contraction for motion tracking of video capsule endoscope

    NASA Astrophysics Data System (ADS)

    Mi, Liang; Bao, Guanqun; Pahlavan, Kaveh

    2014-03-01

    Wireless video capsule endoscope (VCE) provides a noninvasive method to examine the entire gastrointestinal (GI) tract, especially small intestine, where other endoscopic instruments can barely reach. VCE is able to continuously provide clear pictures in short fixed intervals, and as such researchers have attempted to use image processing methods to track the video capsule in order to locate the abnormalities inside the GI tract. To correctly estimate the speed of the motion of the endoscope capsule, the radius of the intestinal track must be known a priori. Physiological factors such as intestinal contraction, however, dynamically change the radius of the small intestine, which could bring large errors in speed estimation. In this paper, we are aiming to estimate the radius of the contracted intestinal track. First a geometric model is presented for estimating the radius of small intestine based on the black hole on endoscopic images. To validate our proposed model, a 3-dimentional virtual testbed that emulates the intestinal contraction is then introduced in details. After measuring the size of the black holes on the test images, we used our model to esimate the radius of the contracted intestinal track. Comparision between analytical results and the emulation model parameters has verified that our proposed method could preciously estimate the radius of the contracted small intestine based on endoscopic images.

  19. Excitation-scanning hyperspectral imaging system for microscopic and endoscopic applications

    NASA Astrophysics Data System (ADS)

    Mayes, Sam A.; Leavesley, Silas J.; Rich, Thomas C.

    2016-04-01

    Current microscopic and endoscopic technologies for cancer screening utilize white-light illumination sources. Hyper-spectral imaging has been shown to improve sensitivity while retaining specificity when compared to white-light imaging in both microscopy and in vivo imaging. However, hyperspectral imaging methods have historically suffered from slow acquisition times due to the narrow bandwidth of spectral filters. Often minutes are required to gather a full image stack. We have developed a novel approach called excitation-scanning hyperspectral imaging that provides 2-3 orders of magnitude increased signal strength. This reduces acquisition times significantly, allowing for live video acquisition. Here, we describe a preliminary prototype excitation-scanning hyperspectral imaging system that can be coupled with endoscopes or microscopes for hyperspectral imaging of tissues and cells. Our system is comprised of three subsystems: illumination, transmission, and imaging. The illumination subsystem employs light-emitting diode arrays to illuminate at different wavelengths. The transmission subsystem utilizes a unique geometry of optics and a liquid light guide. Software controls allow us to interface with and control the subsystems and components. Digital and analog signals are used to coordinate wavelength intensity, cycling and camera triggering. Testing of the system shows it can cycle 16 wavelengths at as fast as 1 ms per cycle. Additionally, more than 18% of the light transmits through the system. Our setup should allow for hyperspectral imaging of tissue and cells in real time.

  20. A CMOS One-chip Wireless Camera with Digital Image Transmission Function for Capsule Endoscopes

    NASA Astrophysics Data System (ADS)

    Itoh, Shinya; Kawahito, Shoji; Terakawa, Susumu

    This paper presents the design and implementation of a one-chip camera device for capsule endoscopes. This experimental chip integrates functional circuits required for capsule endoscopes and digital image transmission function. The integrated functional blocks include an image array, a timing generator, a clock generator, a voltage regulator, a 10b cyclic A/D converter, and a BPSK modulator. It can be operated autonomously with 3 pins (VDD, GND, and DATAOUT). A prototype image sensor chip which has 320x240 effective pixels was fabricated using 0.25μm CMOS image sensor process and the autonomous imaging was demonstrated. The chip size is 4.84mmx4.34mm. With a 2.0 V power supply, the analog part consumes 950μW and the total power consumption at 2 frames per second (fps) is 2.6mW. Error-free image transmission over a distance of 48cm at 2.5Mbps corresponding to 2fps has been succeeded with inductive coupling.

  1. Low Power Transmitter for Wireless Capsule Endoscope

    NASA Astrophysics Data System (ADS)

    Lioe, D. X.; Shafie, S.; Ramiah, H.; Sulaiman, N.; Halin, I. A.

    2013-04-01

    This paper presents the transmitter circuit designed for the application of wireless capsule endoscope to overcome the limitation of conventional endoscope. The design is performed using CMOS 0.13 μm technology. The transmitter is designed to operate at centre frequency of 433.92 MHz, which is one of the ISM band. Active mixer and ring oscillator made up the transmitter and it consumes 1.57 mA of current using a supply voltage of 1.2 V, brings the dc power consumption of the transmitter to be 1.88 mW. Data rate of 3.5 Mbps ensure it can transmit high quality medical imaging.

  2. Design of signal reception and processing system of embedded ultrasonic endoscope

    NASA Astrophysics Data System (ADS)

    Li, Ming; Yu, Feng; Zhang, Ruiqiang; Li, Yan; Chen, Xiaodong; Yu, Daoyin

    2009-11-01

    Embedded Ultrasonic Endoscope, based on embedded microprocessor and embedded real-time operating system, sends a micro ultrasonic probe into coelom through the biopsy channel of the Electronic Endoscope to get the fault histology features of digestive organs by rotary scanning, and acquires the pictures of the alimentary canal mucosal surface. At the same time, ultrasonic signals are processed by signal reception and processing system, forming images of the full histology of the digestive organs. Signal Reception and Processing System is an important component of Embedded Ultrasonic Endoscope. However, the traditional design, using multi-level amplifiers and special digital processing circuits to implement signal reception and processing, is no longer satisfying the standards of high-performance, miniaturization and low power requirements that embedded system requires, and as a result of the high noise that multi-level amplifier brought, the extraction of small signal becomes hard. Therefore, this paper presents a method of signal reception and processing based on double variable gain amplifier and FPGA, increasing the flexibility and dynamic range of the Signal Reception and Processing System, improving system noise level, and reducing power consumption. Finally, we set up the embedded experiment system, using a transducer with the center frequency of 8MHz to scan membrane samples, and display the image of ultrasonic echo reflected by each layer of membrane, with a frame rate of 5Hz, verifying the correctness of the system.

  3. Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Herz, P. R.; Chen, Y.; Aguirre, A. D.; Schneider, K.; Hsiung, P.; Fujimoto, J. G.; Madden, K.; Schmitt, J.; Goodnow, J.; Petersen, C.

    2004-10-01

    A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-µm axial resolution by use of a femtosecond Crforsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

  4. Processing urinary endoscopes in a low-temperature steam and formaldehyde autoclave.

    PubMed Central

    Gibson, G L

    1977-01-01

    Methods of disinfection and sterilisation of urinary endoscopes are considered. A small mobile low-temperature steam and formaldehyde autoclave (Miniclave 80) is evaluated and shown to be satisfactory for this purpose as judged by a variety of relevant microbiological test pieces. Images PMID:557503

  5. Image partitioning and illumination in image-based pose detection for teleoperated flexible endoscopes.

    PubMed

    Bell, Charreau S; Obstein, Keith L; Valdastri, Pietro

    2013-11-01

    Colorectal cancer is one of the leading causes of cancer-related deaths in the world, although it can be effectively treated if detected early. Teleoperated flexible endoscopes are an emerging technology to ease patient apprehension about the procedure, and subsequently increase compliance. Essential to teleoperation is robust feedback reflecting the change in pose (i.e., position and orientation) of the tip of the endoscope. The goal of this study is to first describe a novel image-based tracking system for teleoperated flexible endoscopes, and subsequently determine its viability in a clinical setting. The proposed approach leverages artificial neural networks (ANNs) to learn the mapping that links the optical flow between two sequential images to the change in the pose of the camera. Secondly, the study investigates for the first time how narrow band illumination (NBI) - today available in commercial gastrointestinal endoscopes - can be applied to enhance feature extraction, and quantify the effect of NBI and white light illumination (WLI), as well as their color information, on the strength of features extracted from the endoscopic camera stream. In order to provide the best features for the neural networks to learn the change in pose based on the image stream, we investigated two different imaging modalities - WLI and NBI - and we applied two different spatial partitions - lumen-centered and grid-based - to create descriptors used as input to the ANNs. An experiment was performed to compare the error of these four variations, measured in root mean square error (RMSE) from ground truth given by a robotic arm, to that of a commercial state-of-the-art magnetic tracker. The viability of this technique for a clinical setting was then tested using the four ANN variations, a magnetic tracker, and a commercial colonoscope. The trial was performed by an expert endoscopist (>2000 lifetime procedures) on a colonoscopy training model with porcine blood, and the RMSE of the ANN output was calculated with respect to the magnetic tracker readings. Using the image stream obtained from the commercial endoscope, the strength of features extracted was evaluated. In the first experiment, the best ANNs resulted from grid-based partitioning under WLI (2.42mm RMSE) for position, and from lumen-centered partitioning under NBI (1.69° RMSE) for rotation. By comparison, the performance of the tracker was 2.49mm RMSE in position and 0.89° RMSE in rotation. The trial with the commercial endoscope indicated that lumen-centered partitioning was the best overall, while NBI outperformed WLI in terms of illumination modality. The performance of lumen-centered partitioning with NBI was 1.03±0.8mm RMSE in positional degrees of freedom (DOF), and 1.26±0.98° RMSE in rotational DOF, while with WLI, the performance was 1.56±1.15mm RMSE in positional DOF and 2.45±1.90° RMSE in rotational DOF. Finally, the features extracted under NBI were found to be twice as strong as those extracted under WLI, but no significance in feature strengths was observed between a grayscale version of the image, and the red, blue, and green color channels. This work demonstrates that both WLI and NBI, combined with feature partitioning based on the anatomy of the colon, provide valid mechanisms for endoscopic camera pose estimation via image stream. Illumination provided by WLI and NBI produce ANNs with similar performance which are comparable to that of a state-of-the-art magnetic tracker. However, NBI produces features that are stronger than WLI, which enables more robust feature tracking, and better performance of the ANN in terms of accuracy. Thus, NBI with lumen-centered partitioning resulted the best approach among the different variations tested for vision-based pose estimation. The proposed approach takes advantage of components already available in commercial gastrointestinal endoscopes to provide accurate feedback about the motion of the tip of the endoscope. This solution may serve as an enabling technology for closed-loop control of teleoperated flexible endoscopes. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Fluorescence multi-scale endoscopy and its applications in the study and diagnosis of gastro-intestinal diseases: set-up design and software implementation

    NASA Astrophysics Data System (ADS)

    Gómez-García, Pablo Aurelio; Arranz, Alicia; Fresno, Manuel; Desco, Manuel; Mahmood, Umar; Vaquero, Juan José; Ripoll, Jorge

    2015-06-01

    Endoscopy is frequently used in the diagnosis of several gastro-intestinal pathologies as Crohn disease, ulcerative colitis or colorectal cancer. It has great potential as a non-invasive screening technique capable of detecting suspicious alterations in the intestinal mucosa, such as inflammatory processes. However, these early lesions usually cannot be detected with conventional endoscopes, due to lack of cellular detail and the absence of specific markers. Due to this lack of specificity, the development of new endoscopy technologies, which are able to show microscopic changes in the mucosa structure, are necessary. We here present a confocal endomicroscope, which in combination with a wide field fluorescence endoscope offers fast and specific macroscopic information through the use of activatable probes and a detailed analysis at cellular level of the possible altered tissue areas. This multi-modal and multi-scale imaging module, compatible with commercial endoscopes, combines near-infrared fluorescence (NIRF) measurements (enabling specific imaging of markers of disease and prognosis) and confocal endomicroscopy making use of a fiber bundle, providing a cellular level resolution. The system will be used in animal models exhibiting gastro-intestinal diseases in order to analyze the use of potential diagnostic markers in colorectal cancer. In this work, we present in detail the set-up design and the software implementation in order to obtain simultaneous RGB/NIRF measurements and short confocal scanning times.

  7. Ultrahigh-resolution optical coherence elastography through a micro-endoscope: towards in vivo imaging of cellular-scale mechanics

    PubMed Central

    Fang, Qi; Curatolo, Andrea; Wijesinghe, Philip; Yeow, Yen Ling; Hamzah, Juliana; Noble, Peter B.; Karnowski, Karol; Sampson, David D.; Ganss, Ruth; Kim, Jun Ki; Lee, Woei M.; Kennedy, Brendan F.

    2017-01-01

    In this paper, we describe a technique capable of visualizing mechanical properties at the cellular scale deep in living tissue, by incorporating a gradient-index (GRIN)-lens micro-endoscope into an ultrahigh-resolution optical coherence elastography system. The optical system, after the endoscope, has a lateral resolution of 1.6 µm and an axial resolution of 2.2 µm. Bessel beam illumination and Gaussian mode detection are used to provide an extended depth-of-field of 80 µm, which is a 4-fold improvement over a fully Gaussian beam case with the same lateral resolution. Using this system, we demonstrate quantitative elasticity imaging of a soft silicone phantom containing a stiff inclusion and a freshly excised malignant murine pancreatic tumor. We also demonstrate qualitative strain imaging below the tissue surface on in situ murine muscle. The approach we introduce here can provide high-quality extended-focus images through a micro-endoscope with potential to measure cellular-scale mechanics deep in tissue. We believe this tool is promising for studying biological processes and disease progression in vivo. PMID:29188108

  8. 3D Rapid Prototyping for Otolaryngology-Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling.

    PubMed

    Chan, Harley H L; Siewerdsen, Jeffrey H; Vescan, Allan; Daly, Michael J; Prisman, Eitan; Irish, Jonathan C

    2015-01-01

    The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques across a variety of otolaryngological sub-specialties suggests an emerging role for rapid prototyping technology in surgical education, procedure simulation, and clinical practice.

  9. 3D Rapid Prototyping for Otolaryngology—Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling

    PubMed Central

    Chan, Harley H. L.; Siewerdsen, Jeffrey H.; Vescan, Allan; Daly, Michael J.; Prisman, Eitan; Irish, Jonathan C.

    2015-01-01

    The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques across a variety of otolaryngological sub-specialties suggests an emerging role for rapid prototyping technology in surgical education, procedure simulation, and clinical practice. PMID:26331717

  10. Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography.

    PubMed

    Herz, P R; Chen, Y; Aguirre, A D; Schneider, K; Hsiung, P; Fujimoto, J G; Madden, K; Schmitt, J; Goodnow, J; Petersen, C

    2004-10-01

    A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-microm axial resolution by use of a femtosecond Cr:forsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

  11. Fluorescence lifetime endoscopy using TCSPC for the measurement of FRET in live cells

    PubMed Central

    Fruhwirth, Gilbert O.; Ameer-Beg, Simon; Cook, Richard; Watson, Timothy; Ng, Tony; Festy, Frederic

    2010-01-01

    Development of remote imaging for diagnostic purposes has progressed dramatically since endoscopy began in the 1960’s. The recent advent of a clinically licensed intensity-based fluorescence micro-endoscopic instrument has offered the prospect of real-time cellular resolution imaging. However, interrogating protein-protein interactions deep inside living tissue requires precise fluorescence lifetime measurements to derive the Förster resonance energy transfer between two tagged fluorescent markers. We developed a new instrument combining remote fiber endoscopic cellular-resolution imaging with TCSPC-FLIM technology to interrogate and discriminate mixed fluorochrome labeled beads and expressible GFP/TagRFP tags within live cells. Endoscopic-FLIM (e-FLIM) data was validated by comparison with data acquired via conventional FLIM and e-FLIM was found to be accurate for both bright bead and dim live cell samples. The fiber based micro-endoscope allowed remote imaging of 4 µm and 10 µm beads within a thick Matrigel matrix with confident fluorophore discrimination using lifetime information. More importantly, this new technique enabled us to reliably measure protein-protein interactions in live cells embedded in a 3D matrix, as demonstrated by the dimerization of the fluorescent protein-tagged membrane receptor CXCR4. This cell-based application successfully demonstrated the suitability and great potential of this new technique for in vivo pre-clinical biomedical and possibly human clinical applications. PMID:20588974

  12. Fabrication of a chirped artificial compound eye for endoscopic imaging fiber bundle by dose-modulated laser lithography and subsequent thermal reflow

    NASA Astrophysics Data System (ADS)

    Deng, Shengfeng; Lyu, Jinke; Sun, Hongda; Cui, Xiaobin; Wang, Tun; Lu, Miao

    2015-03-01

    A chirped artificial compound eye on a curved surface was fabricated using an optical resin and then mounted on the end of an endoscopic imaging fiber bundle. The focal length of each lenslet on the curved surface was variable to realize a flat focal plane, which matched the planar end surface of the fiber bundle. The variation of the focal length was obtained by using a photoresist mold formed by dose-modulated laser lithography and subsequent thermal reflow. The imaging performance of the fiber bundle was characterized by coupling with a coaxial light microscope, and the result demonstrated a larger field of view and better imaging quality than that of an artificial compound eye with a uniform focal length. Accordingly, this technology has potential application in stereoscopic endoscopy.

  13. Contrast-enhanced endoscopic ultrasonography: advance and current status

    PubMed Central

    2014-01-01

    Endoscopic ultrasonography (EUS) technology has undergone a great deal of progress along with the color and power Doppler imaging, three-dimensional imaging, electronic scanning, tissue harmonic imaging, and elastography, and one of the most important developments is the ability to acquire contrast-enhanced images. The blood flow in small vessels and the parenchymal microvasculature of the target lesion can be observed non-invasively by contrast-enhanced EUS (CE-EUS). Through a hemodynamic analysis, CE-EUS permits the diagnosis of various gastrointestinal diseases and differential diagnoses between benign and malignant tumors. Recently, mechanical innovations and the development of contrast agents have increased the use of CE-EUS in the diagnostic field, as well as for the assessment of the efficacy of therapeutic agents. The advances in and the current status of CE-EUS are discussed in this review. PMID:25038805

  14. In vivo endoscopic OCT imaging of precancer and cancer states of human mucosa

    NASA Astrophysics Data System (ADS)

    Sergeev, Alexander M.; Gelikonov, V. M.; Gelikonov, G. V.; Feldchtein, Felix I.; Kuranov, R. V.; Gladkova, N. D.; Shakhova, N. M.; Snopova, L. B.; Shakhov, A. V.; Kuznetzova, I. A.; Denisenko, A. N.; Pochinko, V. V.; Chumakov, Yu P.; Streltzova, O. S.

    1997-12-01

    First results of endoscopic applications of optical coherence tomography for in vivo studies of human mucosa in respiratory, gastrointestinal, urinary and genital tracts are presented. A novel endoscopic OCT (EOCT) system has been created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, larynx, stomach, urinary bladder, uterine cervix and body as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancered tissue are distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  15. Integrated endoscopic OCT system and in-vivo images of human internal organs

    NASA Astrophysics Data System (ADS)

    Sergeev, Alexander M.; Gelikonov, Valentin M.; Gelikonov, Grigory V.; Feldchtein, Felix I.; Kuranov, Roman V.; Gladkova, Natalia D.; Shakhova, Natalia M.; Snopova, Ludmila; Shakhov, Andrei; Kuznetzova, Irina N.; Denisenko, Arkady; Pochinko, Vitaly; Chumakov, Yuri; Almasov, Valentin

    1998-04-01

    First results of endoscopic applications of optical coherence tomography (OCT) for in vivo studies of human mucosa in respiratory, gastrointestinal, urinary and genital tracts are presented. A novel endoscopic OCT (EOCT) system has been created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, larynx, stomach, urinary bladder, uterine cervix and endometrium as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancered tissue is distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  16. Ultrahigh resolution optical coherence elastography combined with a rigid micro-endoscope (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Fang, Qi; Curatolo, Andrea; Wijesinghe, Philip; Hamzah, Juliana; Ganss, Ruth; Noble, Peter B.; Karnowski, Karol; Sampson, David D.; Kim, Jun Ki; Lee, Wei M.; Kennedy, Brendan F.

    2017-02-01

    The mechanical forces that living cells experience represent an important framework in the determination of a range of intricate cellular functions and processes. Current insight into cell mechanics is typically provided by in vitro measurement systems; for example, atomic force microscopy (AFM) measurements are performed on cells in culture or, at best, on freshly excised tissue. Optical techniques, such as Brillouin microscopy and optical elastography, have been used for ex vivo and in situ imaging, recently achieving cellular-scale resolution. The utility of these techniques in cell mechanics lies in quick, three-dimensional and label-free mechanical imaging. Translation of these techniques toward minimally invasive in vivo imaging would provide unprecedented capabilities in tissue characterization. Here, we take the first steps along this path by incorporating a gradient-index micro-endoscope into an ultrahigh resolution optical elastography system. Using this endoscope, a lateral resolution of 2 µm is preserved over an extended depth-of-field of 80 µm, achieved by Bessel beam illumination. We demonstrate this combined system by imaging stiffness of a silicone phantom containing stiff inclusions and a freshly excised murine liver tissue. Additionally, we test this system on murine ribs in situ. We show that our approach can provide high quality extended depth-of-field images through an endoscope and has the potential to measure cell mechanics deep in tissue. Eventually, we believe this tool will be capable of studying biological processes and disease progression in vivo.

  17. Ultrahigh speed en face OCT capsule for endoscopic imaging

    PubMed Central

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G.

    2015-01-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications. PMID:25909001

  18. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    PubMed

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  19. Method for radiometric calibration of an endoscope's camera and light source

    NASA Astrophysics Data System (ADS)

    Rai, Lav; Higgins, William E.

    2008-03-01

    An endoscope is a commonly used instrument for performing minimally invasive visual examination of the tissues inside the body. A physician uses the endoscopic video images to identify tissue abnormalities. The images, however, are highly dependent on the optical properties of the endoscope and its orientation and location with respect to the tissue structure. The analysis of endoscopic video images is, therefore, purely subjective. Studies suggest that the fusion of endoscopic video images (providing color and texture information) with virtual endoscopic views (providing structural information) can be useful for assessing various pathologies for several applications: (1) surgical simulation, training, and pedagogy; (2) the creation of a database for pathologies; and (3) the building of patient-specific models. Such fusion requires both geometric and radiometric alignment of endoscopic video images in the texture space. Inconsistent estimates of texture/color of the tissue surface result in seams when multiple endoscopic video images are combined together. This paper (1) identifies the endoscope-dependent variables to be calibrated for objective and consistent estimation of surface texture/color and (2) presents an integrated set of methods to measure them. Results show that the calibration method can be successfully used to estimate objective color/texture values for simple planar scenes, whereas uncalibrated endoscopes performed very poorly for the same tests.

  20. The impact of new technology on surgery for colorectal cancer

    PubMed Central

    Makin, Gregory B; Breen, David J; Monson, John RT

    2001-01-01

    Advances in technology continue at a rapid pace and affect all aspects of life, including surgery. We have reviewed some of these advances and the impact they are having on the investigation and management of colorectal cancer. Modern endoscopes, with magnifying, variable stiffness and localisation capabilities are making the primary investigation of colonic cancer easier and more acceptable for patients. Imaging investigations looking at primary, metastatic and recurrent disease are shifting to digital data sets, which can be stored, reviewed remotely, potentially fused with other modalities and reconstructed as 3 dimensional (3D) images for the purposes of advanced diagnostic interpretation and computer assisted surgery. They include virtual colonoscopy, trans-rectal ultrasound, magnetic resonance imaging, positron emission tomography and radioimmunoscintigraphy. Once a colorectal carcinoma is diagnosed, the treatment options available are expanding. Colonic stents are being used to relieve large bowel obstruction, either as a palliative measure or to improve the patient’s overall condition before definitive surgery. Transanal endoscopic microsurgery and minimally invasive techniques are being used with similar outcomes and a lower mortality, morbidity and hospital stay than open trans-abdominal surgery. Transanal endoscopic microsurgery allows precise excision of both benign and early malignant lesions in the mid and upper rectum. Survival of patients with inoperable hepatic metastases following radiofrequency ablation is encouraging. Robotics and telemedicine are taking surgery well into the 21st century. Artificial neural networks are being developed to enable us to predict the outcome for individual patients. New technology has a major impact on the way we practice surgery for colorectal cancer. PMID:11819841

  1. Extraction of endoscopic images for biomedical figure classification

    NASA Astrophysics Data System (ADS)

    Xue, Zhiyun; You, Daekeun; Chachra, Suchet; Antani, Sameer; Long, L. R.; Demner-Fushman, Dina; Thoma, George R.

    2015-03-01

    Modality filtering is an important feature in biomedical image searching systems and may significantly improve the retrieval performance of the system. This paper presents a new method for extracting endoscopic image figures from photograph images in biomedical literature, which are found to have highly diverse content and large variability in appearance. Our proposed method consists of three main stages: tissue image extraction, endoscopic image candidate extraction, and ophthalmic image filtering. For tissue image extraction we use image patch level clustering and MRF relabeling to detect images containing skin/tissue regions. Next, we find candidate endoscopic images by exploiting the round shape characteristics that commonly appear in these images. However, this step needs to compensate for images where endoscopic regions are not entirely round. In the third step we filter out the ophthalmic images which have shape characteristics very similar to the endoscopic images. We do this by using text information, specifically, anatomy terms, extracted from the figure caption. We tested and evaluated our method on a dataset of 115,370 photograph figures, and achieved promising precision and recall rates of 87% and 84%, respectively.

  2. Dual instrument for in vivo and ex vivo OCT imaging in an ENT department

    PubMed Central

    Cernat, Ramona; Tatla, Taran S.; Pang, Jingyin; Tadrous, Paul J.; Bradu, Adrian; Dobre, George; Gelikonov, Grigory; Gelikonov, Valentin; Podoleanu, Adrian Gh.

    2012-01-01

    A dual instrument is assembled to investigate the usefulness of optical coherence tomography (OCT) imaging in an ear, nose and throat (ENT) department. Instrument 1 is dedicated to in vivo laryngeal investigation, based on an endoscope probe head assembled by compounding a miniature transversal flying spot scanning probe with a commercial fiber bundle endoscope. This dual probe head is used to implement a dual channel nasolaryngeal endoscopy-OCT system. The two probe heads are used to provide simultaneously OCT cross section images and en face fiber bundle endoscopic images. Instrument 2 is dedicated to either in vivo imaging of accessible surface skin and mucosal lesions of the scalp, face, neck and oral cavity or ex vivo imaging of the same excised tissues, based on a single OCT channel. This uses a better interface optics in a hand held probe. The two instruments share sequentially, the swept source at 1300 nm, the photo-detector unit and the imaging PC. An aiming red laser is permanently connected to the two instruments. This projects visible light collinearly with the 1300 nm beam and allows pixel correspondence between the en face endoscopy image and the cross section OCT image in Instrument 1, as well as surface guidance in Instrument 2 for the operator. The dual channel instrument was initially tested on phantom models and then on patients with suspect laryngeal lesions in a busy ENT practice. This feasibility study demonstrates the OCT potential of the dual imaging instrument as a useful tool in the testing and translation of OCT technology from the lab to the clinic. Instrument 1 is under investigation as a possible endoscopic screening tool for early laryngeal cancer. Larger size and better quality cross-section OCT images produced by Instrument 2 provide a reference base for comparison and continuing research on imaging freshly excised tissue, as well as in vivo interrogation of more superficial skin and mucosal lesions in the head and neck patient. PMID:23243583

  3. Quantitative endoscopy: initial accuracy measurements.

    PubMed

    Truitt, T O; Adelman, R A; Kelly, D H; Willging, J P

    2000-02-01

    The geometric optics of an endoscope can be used to determine the absolute size of an object in an endoscopic field without knowing the actual distance from the object. This study explores the accuracy of a technique that estimates absolute object size from endoscopic images. Quantitative endoscopy involves calibrating a rigid endoscope to produce size estimates from 2 images taken with a known traveled distance between the images. The heights of 12 samples, ranging in size from 0.78 to 11.80 mm, were estimated with this calibrated endoscope. Backup distances of 5 mm and 10 mm were used for comparison. The mean percent error for all estimated measurements when compared with the actual object sizes was 1.12%. The mean errors for 5-mm and 10-mm backup distances were 0.76% and 1.65%, respectively. The mean errors for objects <2 mm and > or =2 mm were 0.94% and 1.18%, respectively. Quantitative endoscopy estimates endoscopic image size to within 5% of the actual object size. This method remains promising for quantitatively evaluating object size from endoscopic images. It does not require knowledge of the absolute distance of the endoscope from the object, rather, only the distance traveled by the endoscope between images.

  4. Low-complexity video encoding method for wireless image transmission in capsule endoscope.

    PubMed

    Takizawa, Kenichi; Hamaguchi, Kiyoshi

    2010-01-01

    This paper presents a low-complexity video encoding method applicable for wireless image transmission in capsule endoscopes. This encoding method is based on Wyner-Ziv theory, in which side information available at a transmitter is treated as side information at its receiver. Therefore complex processes in video encoding, such as estimation of the motion vector, are moved to the receiver side, which has a larger-capacity battery. As a result, the encoding process is only to decimate coded original data through channel coding. We provide a performance evaluation for a low-density parity check (LDPC) coding method in the AWGN channel.

  5. The application of coded excitation technology in medical ultrasonic Doppler imaging

    NASA Astrophysics Data System (ADS)

    Li, Weifeng; Chen, Xiaodong; Bao, Jing; Yu, Daoyin

    2008-03-01

    Medical ultrasonic Doppler imaging is one of the most important domains of modern medical imaging technology. The application of coded excitation technology in medical ultrasonic Doppler imaging system has the potential of higher SNR and deeper penetration depth than conventional pulse-echo imaging system, it also improves the image quality, and enhances the sensitivity of feeble signal, furthermore, proper coded excitation is beneficial to received spectrum of Doppler signal. Firstly, this paper analyzes the application of coded excitation technology in medical ultrasonic Doppler imaging system abstractly, showing the advantage and bright future of coded excitation technology, then introduces the principle and the theory of coded excitation. Secondly, we compare some coded serials (including Chirp and fake Chirp signal, Barker codes, Golay's complementary serial, M-sequence, etc). Considering Mainlobe Width, Range Sidelobe Level, Signal-to-Noise Ratio and sensitivity of Doppler signal, we choose Barker codes as coded serial. At last, we design the coded excitation circuit. The result in B-mode imaging and Doppler flow measurement coincided with our expectation, which incarnated the advantage of application of coded excitation technology in Digital Medical Ultrasonic Doppler Endoscope Imaging System.

  6. [Pay attention to the standardized application of new techniques in surgical treatment of thyroid disease].

    PubMed

    Tian, W; Xi, H Q; Wang, B

    2017-08-01

    The continuous development and application of new technology in thyroid surgery has promoted the rapid improvement of thyroid surgery. New technology in the field of thyroid surgery has developed rapidly. The application of neural monitoring technology has enabled the thyroid surgery to enter an accurate era. Imtraoperative neuromonitoring and continuous intraoperative neuromonitoring have made the recurrent laryngeal nerve protection more secure. Nano-carbon parathyroid gland negative imaging technology could identify parathyroid gland more precise. However, when the nano-carbon was used, the injection time, position and dosage should be grasped so as to achieve the best effect of negative imaging. Endoscopic and robotic thyroid surgery could meet the demand of cosmetic. "Treatment first, beauty second" is still the principle to be strictly followed. Do not blindly expand indications and pursue endoscopic surgery. Energy surgical instruments' update made the operation more efficient, while the instruments have some disadvantages. Thyroid surgeon must correctly understand the working principle of new energy devices and use them rationally. Through grasping the working principle and application skills of new technology in clinical work, definiting its advantages and disadvantages, adhereing to the "reasonable choice, standard application" principle, learning the pioneers' experience, the application of new thyroid diagnosis and treatment technology could be more reasonable and safe.

  7. Advanced endoscopic imaging to improve adenoma detection

    PubMed Central

    Neumann, Helmut; Nägel, Andreas; Buda, Andrea

    2015-01-01

    Advanced endoscopic imaging is revolutionizing our way on how to diagnose and treat colorectal lesions. Within recent years a variety of modern endoscopic imaging techniques was introduced to improve adenoma detection rates. Those include high-definition imaging, dye-less chromoendoscopy techniques and novel, highly flexible endoscopes, some of them equipped with balloons or multiple lenses in order to improve adenoma detection rates. In this review we will focus on the newest developments in the field of colonoscopic imaging to improve adenoma detection rates. Described techniques include high-definition imaging, optical chromoendoscopy techniques, virtual chromoendoscopy techniques, the Third Eye Retroscope and other retroviewing devices, the G-EYE endoscope and the Full Spectrum Endoscopy-system. PMID:25789092

  8. An endoscopic diffuse optical tomographic method with high resolution based on the improved FOCUSS method

    NASA Astrophysics Data System (ADS)

    Qin, Zhuanping; Ma, Wenjuan; Ren, Shuyan; Geng, Liqing; Li, Jing; Yang, Ying; Qin, Yingmei

    2017-02-01

    Endoscopic DOT has the potential to apply to cancer-related imaging in tubular organs. Although the DOT has relatively large tissue penetration depth, the endoscopic DOT is limited by the narrow space of the internal tubular tissue, so as to the relatively small penetration depth. Because some adenocarcinomas including cervical adenocarcinoma are located in deep canal, it is necessary to improve the imaging resolution under the limited measurement condition. To improve the resolution, a new FOCUSS algorithm along with the image reconstruction algorithm based on the effective detection range (EDR) is developed. This algorithm is based on the region of interest (ROI) to reduce the dimensions of the matrix. The shrinking method cuts down the computation burden. To reduce the computational complexity, double conjugate gradient method is used in the matrix inversion. For a typical inner size and optical properties of the cervix-like tubular tissue, reconstructed images from the simulation data demonstrate that the proposed method achieves equivalent image quality to that obtained from the method based on EDR when the target is close the inner boundary of the model, and with higher spatial resolution and quantitative ratio when the targets are far from the inner boundary of the model. The quantitative ratio of reconstructed absorption and reduced scattering coefficient can be up to 70% and 80% under 5mm depth, respectively. Furthermore, the two close targets with different depths can be separated from each other. The proposed method will be useful to the development of endoscopic DOT technologies in tubular organs.

  9. Application of artificial intelligence using a convolutional neural network for detecting gastric cancer in endoscopic images.

    PubMed

    Hirasawa, Toshiaki; Aoyama, Kazuharu; Tanimoto, Tetsuya; Ishihara, Soichiro; Shichijo, Satoki; Ozawa, Tsuyoshi; Ohnishi, Tatsuya; Fujishiro, Mitsuhiro; Matsuo, Keigo; Fujisaki, Junko; Tada, Tomohiro

    2018-07-01

    Image recognition using artificial intelligence with deep learning through convolutional neural networks (CNNs) has dramatically improved and been increasingly applied to medical fields for diagnostic imaging. We developed a CNN that can automatically detect gastric cancer in endoscopic images. A CNN-based diagnostic system was constructed based on Single Shot MultiBox Detector architecture and trained using 13,584 endoscopic images of gastric cancer. To evaluate the diagnostic accuracy, an independent test set of 2296 stomach images collected from 69 consecutive patients with 77 gastric cancer lesions was applied to the constructed CNN. The CNN required 47 s to analyze 2296 test images. The CNN correctly diagnosed 71 of 77 gastric cancer lesions with an overall sensitivity of 92.2%, and 161 non-cancerous lesions were detected as gastric cancer, resulting in a positive predictive value of 30.6%. Seventy of the 71 lesions (98.6%) with a diameter of 6 mm or more as well as all invasive cancers were correctly detected. All missed lesions were superficially depressed and differentiated-type intramucosal cancers that were difficult to distinguish from gastritis even for experienced endoscopists. Nearly half of the false-positive lesions were gastritis with changes in color tone or an irregular mucosal surface. The constructed CNN system for detecting gastric cancer could process numerous stored endoscopic images in a very short time with a clinically relevant diagnostic ability. It may be well applicable to daily clinical practice to reduce the burden of endoscopists.

  10. Analysis and design of stereoscopic display in stereo television endoscope system

    NASA Astrophysics Data System (ADS)

    Feng, Dawei

    2008-12-01

    Many 3D displays have been proposed for medical use. When we design and evaluate new system, there are three demands from surgeons. Priority is the precision. Secondly, displayed images should be easy to understand, In addition, surgery lasts hours and hours, they do not like fatiguing display. The stereo television endoscope researched in this paper make celiac viscera image on the photosurface of the left and right CCD by imitating human binocular stereo vision effect by using the double-optical lines system. The left and right video signal will be processed by frequency multiplication and display on the monitor, people can observe the stereo image which has depth impression by using a polarized LCD screen and a pair of polarized glasses. Clinical experiments show that by using the stereo TV endoscope people can make minimally invasive surgery more safe and reliable, and can shorten the operation time, and can improve the operation accuracy.

  11. Analysis of the color rendition of flexible endoscopes

    NASA Astrophysics Data System (ADS)

    Murphy, Edward M.; Hegarty, Francis J.; McMahon, Barry P.; Boyle, Gerard

    2003-03-01

    Endoscopes are imaging devices routinely used for the diagnosis of disease within the human digestive tract. Light is transmitted into the body cavity via incoherent fibreoptic bundles and is controlled by a light feedback system. Fibreoptic endoscopes use coherent fibreoptic bundles to provide the clinician with an image. It is also possible to couple fibreoptic endoscopes to a clip-on video camera. Video endoscopes consist of a small CCD camera, which is inserted into gastrointestinal tract, and associated image processor to convert the signal to analogue RGB video signals. Images from both types of endoscope are displayed on standard video monitors. Diagnosis is dependent upon being able to determine changes in the structure and colour of tissues and biological fluids, and therefore is dependent upon the ability of the endoscope to reproduce the colour of these tissues and fluids with fidelity. This study investigates the colour reproduction of flexible optical and video endoscopes. Fibreoptic and video endoscopes alter image colour characteristics in different ways. The colour rendition of fibreoptic endoscopes was assessed by coupling them to a video camera and applying video colorimetric techniques. These techniques were then used on video endoscopes to assess how the colour rendition of video endoscopes compared with that of optical endoscopes. In both cases results were obtained at fixed illumination settings. Video endoscopes were then assessed with varying levels of illumination. Initial results show that at constant luminance endoscopy systems introduce non-linear shifts in colour. Techniques for examining how this colour shift varies with illumination intensity were developed and both methodology and results will be presented. We conclude that more rigorous quality assurance is required to reduce colour error and are developing calibration procedures applicable to medical endoscopes.

  12. Wireless fluorescence capsule for endoscopy using single photon-based detection

    NASA Astrophysics Data System (ADS)

    Al-Rawhani, Mohammed A.; Beeley, James; Cumming, David R. S.

    2015-12-01

    Fluorescence Imaging (FI) is a powerful technique in biological science and clinical medicine. Current FI devices that are used either for in-vivo or in-vitro studies are expensive, bulky and consume substantial power, confining the technique to laboratories and hospital examination rooms. Here we present a miniaturised wireless fluorescence endoscope capsule with low power consumption that will pave the way for future FI systems and applications. With enhanced sensitivity compared to existing technology we have demonstrated that the capsule can be successfully used to image tissue autofluorescence and targeted fluorescence via fluorophore labelling of tissues. The capsule incorporates a state-of-the-art complementary metal oxide semiconductor single photon avalanche detector imaging array, miniaturised optical isolation, wireless technology and low power design. When in use the capsule consumes only 30.9 mW, and deploys very low-level 468 nm illumination. The device has the potential to replace highly power-hungry intrusive optical fibre based endoscopes and to extend the range of clinical examination below the duodenum. To demonstrate the performance of our capsule, we imaged fluorescence phantoms incorporating principal tissue fluorophores (flavins) and absorbers (haemoglobin). We also demonstrated the utility of marker identification by imaging a 20 μM fluorescein isothiocyanate (FITC) labelling solution on mammalian tissue.

  13. Development of a telediagnosis endoscopy system over secure internet.

    PubMed

    Ohashi, K; Sakamoto, N; Watanabe, M; Mizushima, H; Tanaka, H

    2008-01-01

    We developed a new telediagnosis system to securely transmit high-quality endoscopic moving images over the Internet in real time. This system would enable collaboration between physicians seeking advice from endoscopists separated by long distances, to facilitate diagnosis. We adapted a new type of digital video streaming system (DVTS) to our teleendoscopic diagnosis system. To investigate its feasibility, we conducted a two-step experiment. A basic experiment was first conducted to transmit endoscopic video images between hospitals using a plain DVTS. After investigating the practical usability, we incorporated a secure and reliable communication function into the system, by equipping DVTS with "TCP2", a new security technology that establishes secure communication in the transport layer. The second experiment involved international transmission of teleendoscopic image between Hawaii and Japan using the improved system. In both the experiments, no serious transmission delay was observed to disturb physicians' communications and, after subjective evaluation by endoscopists, the diagnostic qualities of the images were found to be adequate. Moreover, the second experiment showed that "TCP2-equipped DVTS" successfully executed high-quality secure image transmission over a long distance network. We conclude that DVTS technology would be promising for teleendoscopic diagnosis. It was also shown that a high quality, secure teleendoscopic diagnosis system can be developed by equipping DVTS with TCP2.

  14. In-vivo gingival sulcus imaging using full-range, complex-conjugate-free, endoscopic spectral domain optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Huang, Yong; Zhang, Kang; Yi, WonJin; Kang, Jin U.

    2012-01-01

    Frequent monitoring of gingival sulcus will provide valuable information for judging the presence and severity of periodontal disease. Optical coherence tomography, as a 3D high resolution high speed imaging modality is able to provide information for pocket depth, gum contour, gum texture, gum recession simultaneously. A handheld forward-viewing miniature resonant fiber-scanning probe was developed for in-vivo gingival sulcus imaging. The fiber cantilever driven by magnetic force vibrates at resonant frequency. A synchronized linear phase-modulation was applied in the reference arm by the galvanometer-driven reference mirror. Full-range, complex-conjugate-free, real-time endoscopic SD-OCT was achieved by accelerating the data process using graphics processing unit. Preliminary results showed a real-time in-vivo imaging at 33 fps with an imaging range of lateral 2 mm by depth 3 mm. Gap between the tooth and gum area was clearly visualized. Further quantification analysis of the gingival sulcus will be performed on the image acquired.

  15. Transsphenoidal Approach in Endoscopic Endonasal Surgery for Skull Base Lesions: What Radiologists and Surgeons Need to Know.

    PubMed

    García-Garrigós, Elena; Arenas-Jiménez, Juan José; Monjas-Cánovas, Irene; Abarca-Olivas, Javier; Cortés-Vela, Jesús Julián; De La Hoz-Rosa, Javier; Guirau-Rubio, Maria Dolores

    2015-01-01

    In the last 2 decades, endoscopic endonasal transsphenoidal surgery has become the most popular choice of neurosurgeons and otolaryngologists to treat lesions of the skull base, with minimal invasiveness, lower incidence of complications, and lower morbidity and mortality rates compared with traditional approaches. The transsphenoidal route is the surgical approach of choice for most sellar tumors because of the relationship of the sphenoid bone to the nasal cavity below and the pituitary gland above. More recently, extended approaches have expanded the indications for transsphenoidal surgery by using different corridors leading to specific target areas, from the crista galli to the spinomedullary junction. Computer-assisted surgery is an evolving technology that allows real-time anatomic navigation during endoscopic surgery by linking preoperative triplanar radiologic images and intraoperative endoscopic views, thus helping the surgeon avoid damage to vital structures. Preoperative computed tomography is the preferred modality to show bone landmarks and vascular structures. Radiologists play an important role in surgical planning by reporting extension of sphenoid pneumatization, recesses and septations of the sinus, and other relevant anatomic variants. Radiologists should understand the relationships of the sphenoid bone and skull base structures, anatomic variants, and image-guided neuronavigation techniques to prevent surgical complications and allow effective treatment of skull base lesions with the endoscopic endonasal transsphenoidal approach. ©RSNA, 2015.

  16. Chromaticity based smoke removal in endoscopic images

    NASA Astrophysics Data System (ADS)

    Tchaka, Kevin; Pawar, Vijay M.; Stoyanov, Danail

    2017-02-01

    In minimally invasive surgery, image quality is a critical pre-requisite to ensure a surgeons ability to perform a procedure. In endoscopic procedures, image quality can deteriorate for a number of reasons such as fogging due to the temperature gradient after intra-corporeal insertion, lack of focus and due to smoke generated when using electro-cautery to dissect tissues without bleeding. In this paper we investigate the use of vision processing techniques to remove surgical smoke and improve the clarity of the image. We model the image formation process by introducing a haze medium to account for the degradation of visibility. For simplicity and computational efficiency we use an adapted dark-channel prior method combined with histogram equalization to remove smoke artifacts to recover the radiance image and enhance the contrast and brightness of the final result. Our initial results on images from robotic assisted procedures are promising and show that the proposed approach may be used to enhance image quality during surgery without additional suction devices. In addition, the processing pipeline may be used as an important part of a robust surgical vision pipeline that can continue working in the presence of smoke.

  17. Design of a handheld optical coherence microscopy endoscope

    NASA Astrophysics Data System (ADS)

    Korde, Vrushali R.; Liebmann, Erica; Barton, Jennifer K.

    2011-06-01

    Optical coherence microscopy (OCM) combines coherence gating, high numerical aperture optics, and a fiber-core pinhole to provide high axial and lateral resolution with relatively large depth of imaging. We present a handheld rigid OCM endoscope designed for small animal surgical imaging, with a 6-mm diam tip, 1-mm scan width, and 1-mm imaging depth. X-Y scanning is performed distally with mirrors mounted to micro galvonometer scanners incorporated into the endoscope handle. The endoscope optical design consists of scanning doublets, an afocal Hopkins relay lens system, a 0.4 numerical aperture water immersion objective, and a cover glass. This endoscope can resolve laterally a 1.4-μm line pair feature and has an axial resolution (full width half maximum) of 5.4 μm. Images taken with this endoscope of fresh ex-vivo mouse ovaries show structural features, such as corpus luteum, primary follicles, growing follicles, and fallopian tubes. This rigid handheld OCM endoscope can be useful for a variety of minimally invasive and surgical imaging applications.

  18. The Clinical Accuracy of Endoscopic Ultrasonography and White Light Imaging in Gastric Endoscopic Submucosal Dissection

    PubMed Central

    Park, Soon Hong; Sung, Sang Hun; Lee, Seung Jun; Jung, Min Kyu; Kim, Sung Kook

    2012-01-01

    Purpose Gastric mucosal neoplastic lesions should have characteristic endoscopic features for successful endoscopic submucosal dissection. Materials and Methods Out of the 1,010 endoscopic submucosal dissection, we enrolled 62 patients that had the procedure cancelled. Retrospectively, whether the reasons for cancelling the endoscopic submucosal dissection were consistent with the indications for an endoscopic submucosal dissection were assessed by analyzing the clinical outcomes of the patients that had the surgery. Results The cases were divided into two groups; the under-diagnosed group (30 cases; unable to perform an endoscopic submucosal dissection) and the over-diagnosed group (32 cases; unnecessary to perform an endoscopic submucosal dissection), according to the second endoscopic findings, compared with the index conventional white light image. There were six cases in the under-diagnosed group with advanced gastric cancer on the second conventional white light image endoscopy, 17 cases with submucosal invasion on endoscopic ultrasonography findings, 5 cases with a size greater than 3 cm and ulcer, 1 case with diffuse infiltrative endoscopic features, and 1 case with lymph node involvement on computed tomography. A total of 25 patients underwent a gastrectomy to remove a gastric adenocarcinoma. The overall accuracy of the decision to cancel the endoscopic submucosal dissection was 40% (10/25) in the subgroup that had the surgery. Conclusions The accuracy of the decision to cancel the endoscopic submucosal dissection, after conventional white light image and endoscopic ultrasonography, was low in this study. Other diagnostic options are needed to arrive at an accurate decision on whether to perform a gastric endoscopic submucosal dissection. PMID:22792522

  19. Combining endoscopic ultrasound with Time-Of-Flight PET: The EndoTOFPET-US Project

    NASA Astrophysics Data System (ADS)

    Frisch, Benjamin

    2013-12-01

    The EndoTOFPET-US collaboration develops a multimodal imaging technique for endoscopic exams of the pancreas or the prostate. It combines the benefits of high resolution metabolic imaging with Time-Of-Flight Positron Emission Tomography (TOF PET) and anatomical imaging with ultrasound (US). EndoTOFPET-US consists of a PET head extension for a commercial US endoscope and a PET plate outside the body in coincidence with the head. The high level of miniaturization and integration creates challenges in fields such as scintillating crystals, ultra-fast photo-detection, highly integrated electronics, system integration and image reconstruction. Amongst the developments, fast scintillators as well as fast and compact digital SiPMs with single SPAD readout are used to obtain the best coincidence time resolution (CTR). Highly integrated ASICs and DAQ electronics contribute to the timing performances of EndoTOFPET. In view of the targeted resolution of around 1 mm in the reconstructed image, we present a prototype detector system with a CTR better than 240 ps FWHM. We discuss the challenges in simulating such a system and introduce reconstruction algorithms based on graphics processing units (GPU).

  20. Image-enhanced endoscopy for diagnosis of colorectal tumors in view of endoscopic treatment

    PubMed Central

    Yoshida, Naohisa; Yagi, Nobuaki; Yanagisawa, Akio; Naito, Yuji

    2012-01-01

    Recently, image-enhanced endoscopy (IEE) has been used to diagnose gastrointestinal tumors. This method is a change from conventional white-light (WL) endoscopy without dyeing solution, requiring only the push of a button. In IEE, there are many advantages in diagnosis of neoplastic tumors, evaluation of invasion depth for cancerous lesions, and detection of neoplastic lesions. In narrow band imaging (NBI) systems (Olympus Medical Co., Tokyo, Japan), optical filters that allow narrow-band light to pass at wavelengths of 415 and 540 nm are used. Mucosal surface blood vessels are seen most clearly at 415 nm, which is the wavelength that corresponds to the hemoglobin absorption band, while vessels in the deep layer of the mucosa can be detected at 540 nm. Thus, NBI also can detect pit-like structures named surface pattern. The flexible spectral imaging color enhancement (FICE) system (Fujifilm Medical Co., Tokyo, Japan) is also an IEE but different to NBI. FICE depends on the use of spectral-estimation technology to reconstruct images at different wavelengths based on WL images. FICE can enhance vascular and surface patterns. The autofluorescence imaging (AFI) video endoscope system (Olympus Medical Co., Tokyo, Japan) is a new illumination method that uses the difference in intensity of autofluorescence between the normal area and neoplastic lesions. AFI light comprises a blue light for emitting and a green light for hemoglobin absorption. The aim of this review is to highlight the efficacy of IEE for diagnosis of colorectal tumors for endoscopic treatment. PMID:23293724

  1. [Experience of Fusion image guided system in endonasal endoscopic surgery].

    PubMed

    Wen, Jingying; Zhen, Hongtao; Shi, Lili; Cao, Pingping; Cui, Yonghua

    2015-08-01

    To review endonasal endoscopic surgeries aided by Fusion image guided system, and to explore the application value of Fusion image guided system in endonasal endoscopic surgeries. Retrospective research. Sixty cases of endonasal endoscopic surgeries aided by Fusion image guided system were analysed including chronic rhinosinusitis with polyp (n = 10), fungus sinusitis (n = 5), endoscopic optic nerve decompression (n = 16), inverted papilloma of the paranasal sinus (n = 9), ossifying fibroma of sphenoid bone (n = 1), malignance of the paranasal sinus (n = 9), cerebrospinal fluid leak (n = 5), hemangioma of orbital apex (n = 2) and orbital reconstruction (n = 3). Sixty cases of endonasal endoscopic surgeries completed successfully without any complications. Fusion image guided system can help to identify the ostium of paranasal sinus, lamina papyracea and skull base. Fused CT-CTA images, or fused MR-MRA images can help to localize the optic nerve or internal carotid arteiy . Fused CT-MR images can help to detect the range of the tumor. It spent (7.13 ± 1.358) minutes for image guided system to do preoperative preparation and the surgical navigation accuracy reached less than 1mm after proficient. There was no device localization problem because of block or head set loosed. Fusion image guided system make endonasal endoscopic surgery to be a true microinvasive and exact surgery. It spends less preoperative preparation time, has high surgical navigation accuracy, improves the surgical safety and reduces the surgical complications.

  2. ERCP (Endoscopic Retrograde Cholangiopancreatography)

    MedlinePlus

    ... Process Research Training & Career Development Funded Grants & Grant History Research Resources Research at NIDDK Technology Advancement & Transfer Meetings & Workshops Health Information Diabetes Digestive ...

  3. LED-based endoscopic light source for spectral imaging

    NASA Astrophysics Data System (ADS)

    Browning, Craig M.; Mayes, Samuel; Favreau, Peter; Rich, Thomas C.; Leavesley, Silas J.

    2016-03-01

    Colorectal cancer is the United States 3rd leading cancer in death rates.1 The current screening for colorectal cancer is an endoscopic procedure using white light endoscopy (WLE). There are multiple new methods testing to replace WLE, for example narrow band imaging and autofluorescence imaging.2 However, these methods do not meet the need for a higher specificity or sensitivity. The goal for this project is to modify the presently used endoscope light source to house 16 narrow wavelength LEDs for spectral imaging in real time while increasing sensitivity and specificity. The process to do such was to take an Olympus CLK-4 light source, replace the light and electronics with 16 LEDs and new circuitry. This allows control of the power and intensity of the LEDs. This required a larger enclosure to house a bracket system for the solid light guide (lightpipe), three new circuit boards, a power source and National Instruments hardware/software for computer control. The results were a successfully designed retrofit with all the new features. The LED testing resulted in the ability to control each wavelength's intensity. The measured intensity over the voltage range will provide the information needed to couple the camera for imaging. Overall the project was successful; the modifications to the light source added the controllable LEDs. This brings the research one step closer to the main goal of spectral imaging for early detection of colorectal cancer. Future goals will be to connect the camera and test the imaging process.

  4. Evaluation of endoscopic entire 3D image acquisition of the digestive tract using a stereo endoscope

    NASA Astrophysics Data System (ADS)

    Yoshimoto, Kayo; Watabe, Kenji; Fujinaga, Tetsuji; Iijima, Hideki; Tsujii, Masahiko; Takahashi, Hideya; Takehara, Tetsuo; Yamada, Kenji

    2017-02-01

    Because the view angle of the endoscope is narrow, it is difficult to get the whole image of the digestive tract at once. If there are more than two lesions in the digestive tract, it is hard to understand the 3D positional relationship among the lesions. Virtual endoscopy using CT is a present standard method to get the whole view of the digestive tract. Because the virtual endoscopy is designed to detect the irregularity of the surface, it cannot detect lesions that lack irregularity including early cancer. In this study, we propose a method of endoscopic entire 3D image acquisition of the digestive tract using a stereo endoscope. The method is as follows: 1) capture sequential images of the digestive tract by moving the endoscope, 2) reconstruct 3D surface pattern for each frame by stereo images, 3) estimate the position of the endoscope by image analysis, 4) reconstitute the entire image of the digestive tract by combining the 3D surface pattern. To confirm the validity of this method, we experimented with a straight tube inside of which circles were allocated at equal distance of 20 mm. We captured sequential images and the reconstituted image of the tube revealed that the distance between each circle was 20.2 +/- 0.3 mm (n=7). The results suggest that this method of endoscopic entire 3D image acquisition may help us understand 3D positional relationship among the lesions such as early esophageal cancer that cannot be detected by virtual endoscopy using CT.

  5. The endoscopic diagnosis of nonerosive reflux disease using flexible spectral imaging color enhancement image: a feasibility trial.

    PubMed

    Miyasaka, M; Hirakawa, M; Nakamura, K; Tanaka, F; Mimori, K; Mori, M; Honda, H

    2011-08-01

    Nonerosive reflux disease (NERD) is classified into grade M (minimal change, endoscopically; erythema without sharp demarcation, whitish turbidity, and/or invisibility of vessels due to these findings) and grade N (normal) in the modified Los Angeles classification system in Japan. However, the classification of grades M and N NERD is not included in the original Los Angeles system because interobserver agreement for the conventional endoscopic diagnosis of grades M or N NERD is poor. Flexible spectral imaging color enhancement (FICE) is a virtual chromoendoscopy technique that enhances mucosal and vascular visibility. The aim of this study is to evaluate whether the endoscopic diagnosis of grades M or N NERD using FICE images is feasible. Between April 2006 and May 2008, 26 NERD patients and 31 controls were enrolled in the present study. First, an experienced endoscopist assessed the color pattern of minimal change in FICE images using conventional endoscopic images and FICE images side-by-side and comparing the proportion of minimal change between the two groups. Second, three blinded endoscopists assessed the presence or absence of minimal change in both groups using conventional endoscopic images and FICE images separately. Intraobserver variability was compared using McNemar's test, and interobserver agreement was described using the kappa value. Minimal changes, such as erythema and whitish turbidity, which were detected using conventional endoscopic images, showed up as navy blue and pink-white, respectively, in color using FICE images in the present FICE mode. The NERD group had a higher proportion of minimal change, compared with the control group (77% and 48%, respectively) (P= 0.033). In all three readers, the detection rates of minimal change using FICE images were greater than those using conventional endoscopic images (P= 0.025, <0.0001, and 0.034 for readers A, B, and C, respectively). The kappa values for all pairs of three readers using FICE images were between 0.683 and 0.812, while those using conventional endoscopic images were between 0.364 and 0.624. Thus, the endoscopic diagnosis of grades M or N NERD using FICE images is feasible and may improve interobserver agreement. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  6. Emerging Endoscopic Imaging Technologies for Bladder Cancer Detection

    PubMed Central

    Lopez, Aristeo; Liao, Joseph C.

    2014-01-01

    Modern urologic endoscopy is the result of continuous innovations since early 19th century. White light cystoscopy is the primary strategy for identification, resection, and local staging of bladder cancer. While highly effective, white light cystoscopy has several well-recognized shortcomings. Recent advances in optical imaging technologies and device miniaturization hold the potential to improve bladder cancer diagnosis and resection. Photodynamic diagnosis and narrow band imaging are the first to enter the clinical arena. Confocal laser endomicroscopy, optical coherence tomography, Raman spectroscopy, UV autofluorescence, and others have shown promising clinical and pre-clinical feasibility. We review their mechanisms of action, highlight their respective advantages, and propose future directions. PMID:24658832

  7. Automatic specular reflections removal for endoscopic images

    NASA Astrophysics Data System (ADS)

    Tan, Ke; Wang, Bin; Gao, Yuan

    2017-07-01

    Endoscopy imaging is utilized to provide a realistic view about the surfaces of organs inside the human body. Owing to the damp internal environment, these surfaces usually have a glossy appearance showing specular reflections. For many computer vision algorithms, the highlights created by specular reflections may become a significant source of error. In this paper, we present a novel method for restoration of the specular reflection regions from a single image. Specular restoration process starts with generating a substitute specular-free image with RPCA method. Then the specular removed image was obtained by taking the binary weighting template of highlight regions as the weighting for merging the original specular image and the substitute image. The modified template was furthermore discussed for the concealment of artificial effects in the edge of specular regions. Experimental results on the removal of the endoscopic image with specular reflections demonstrate the efficiency of the proposed method comparing to the existing methods.

  8. Dynamic focus-tracking MEMS scanning micromirror with low actuation voltages for endoscopic imaging.

    PubMed

    Strathman, Matthew; Liu, Yunbo; Li, Xingde; Lin, Lih Y

    2013-10-07

    We demonstrate a 3-D scanning micromirror device that combines 2-D beam scanning with focus control in the same device using micro-electro-mechanical-systems (MEMS) technology. 2-D beam scanning is achieved with a biaxial gimbal structure and focus control is obtained with a deformable mirror membrane surface. The micromirror with 800 micrometer diameter is designed to be sufficiently compact and efficient so that it can be incorporated into an endoscopic imaging probe in the future. The design, fabrication and characterization of the device are described in this paper. Using the focus-tracking MEMS scanning mirror, we achieved an optical scanning range of >16 degrees with <40 V actuation voltage at resonance and a tunable focal length between infinity and 25 mm with <100V applied bias.

  9. Real-time endoscopic image orientation correction system using an accelerometer and gyrosensor.

    PubMed

    Lee, Hyung-Chul; Jung, Chul-Woo; Kim, Hee Chan

    2017-01-01

    The discrepancy between spatial orientations of an endoscopic image and a physician's working environment can make it difficult to interpret endoscopic images. In this study, we developed and evaluated a device that corrects the endoscopic image orientation using an accelerometer and gyrosensor. The acceleration of gravity and angular velocity were retrieved from the accelerometer and gyrosensor attached to the handle of the endoscope. The rotational angle of the endoscope handle was calculated using a Kalman filter with transmission delay compensation. Technical evaluation of the orientation correction system was performed using a camera by comparing the optical rotational angle from the captured image with the rotational angle calculated from the sensor outputs. For the clinical utility test, fifteen anesthesiology residents performed a video endoscopic examination of an airway model with and without using the orientation correction system. The participants reported numbers written on papers placed at the left main, right main, and right upper bronchi of the airway model. The correctness and the total time it took participants to report the numbers were recorded. During the technical evaluation, errors in the calculated rotational angle were less than 5 degrees. In the clinical utility test, there was a significant time reduction when using the orientation correction system compared with not using the system (median, 52 vs. 76 seconds; P = .012). In this study, we developed a real-time endoscopic image orientation correction system, which significantly improved physician performance during a video endoscopic exam.

  10. Virtual endoscopy in neurosurgery: a review.

    PubMed

    Neubauer, André; Wolfsberger, Stefan

    2013-01-01

    Virtual endoscopy is the computerized creation of images depicting the inside of patient anatomy reconstructed in a virtual reality environment. It permits interactive, noninvasive, 3-dimensional visual inspection of anatomical cavities or vessels. This can aid in diagnostics, potentially replacing an actual endoscopic procedure, and help in the preparation of a surgical intervention by bridging the gap between plain 2-dimensional radiologic images and the 3-dimensional depiction of anatomy during actual endoscopy. If not only the endoscopic vision but also endoscopic handling, including realistic haptic feedback, is simulated, virtual endoscopy can be an effective training tool for novice surgeons. In neurosurgery, the main fields of the application of virtual endoscopy are third ventriculostomy, endonasal surgery, and the evaluation of pathologies in cerebral blood vessels. Progress in this very active field of research is achieved through cooperation between the technical and the medical communities. While the technology advances and new methods for modeling, reconstruction, and simulation are being developed, clinicians evaluate existing simulators, steer the development of new ones, and explore new fields of application. This review introduces some of the most interesting virtual reality systems for endoscopic neurosurgery developed in recent years and presents clinical studies conducted either on areas of application or specific systems. In addition, benefits and limitations of single products and simulated neuroendoscopy in general are pointed out.

  11. 3-D endoscopic imaging using plenoptic camera.

    PubMed

    Le, Hanh N D; Decker, Ryan; Opferman, Justin; Kim, Peter; Krieger, Axel; Kang, Jin U

    2016-06-01

    Three-dimensional endoscopic imaging using plenoptic technique combined with F-matching algorithm has been pursued in this study. A custom relay optics was designed to integrate a commercial surgical straight endoscope with a plenoptic camera.

  12. [Informatics, robotics and medicine].

    PubMed

    Carpentier, A

    1999-01-01

    Information technology is becoming common use in Medicine. Among the numerous applications are data processing, image analysis, 3D reconstruction, telemedicine, to mention only few of them. The interest of computers in surgical research and development is lesser known. Two examples are given: computer aided conception and simulation of physiologic systems. Robotics has been introduced more recently. There are three types of robotics corresponding to three types of use: targetting used by neural surgeons to localize tumors or anatomical structures, visualization used by general surgeons to hold and mobilize laparoscopes, instrumentation introduced more recently by cardiac surgeons to perform totally endoscopic cardiac operations. All these techniques open new ways for tomorrow "Instrumental Medicine".

  13. Endoscopic fluorescence imaging for early assessment of anastomotic recurrence of Crohn's disease

    NASA Astrophysics Data System (ADS)

    Mordon, Serge R.; Maunoury, Vincent; Geboes, K.; Klein, Olivier; Desreumaux, P.; Debaert, A.; Colombel, Jean-Frederic

    1999-02-01

    Crohn's disease is an inflammatory bowel disease of unknown etiology. The mechanism of the initial mucosal alterations is still unclear: ulcerations overlying lymphoid follicles and/or vasculitis have been proposed as the early lesions. We have developed a new and original method combining endoscopy of fluorescence angiography for identifying the early pathological lesions, occurring in the neo-terminal ileum after right ileocolonic resection. The patient population consisted of 10 subjects enrolled in a prospective protocol of endoscopic follow-up at 3 and 12 months after surgery. Fluorescence imaging showed small spots giving a bright fluorescence distributed singly in mucosa which appeared normal in routine endoscopy. Histopathological examination demonstrated that the fluorescence of small spots originated from small, usually superficial, erosive lesions. In several cases, these erosive lesions occurred over lymphoid follicles. Endoscopic fluorescence imaging provides a suitable means of investigating the initial aspect of the Crohn's disease process in displaying some correlative findings between fluorescent aspects and early pathological mucosal alterations.

  14. SECM half-inch tethered endoscopic capsule (HITEC) for esophageal imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kang, DongKyun; Kim, Minkyu; Carruth, Robert W.; Lu, Weina; Wu, Tao; Alali, Sanaz; Do, Dukho; Soomro, Amna R.; Grant, Catriona N.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.

    2016-03-01

    Spectrally encoded confocal microscopy (SECM) is a high-speed confocal endomicroscopy technology that can image extremely large regions of human tissue at cellular resolution within a short imaging time. Previously, we have developed a 7-mm-diameter SECM endoscopic capsule and successfully demonstrated imaging of human esophagus in vivo. Even though we were able to successfully capture images with the previous capsule, it suffered from two limitations: (1) the capsule had a small diameter, which provided a limited contact between SECM capsule and esophagus; and (2) speckle noise in SECM images made it challenging to appreciate cellular features. In this paper, we present a new SECM capsule, termed SECM half-inch tethered endoscopic capsule (HITEC), which addresses the two aforementioned technical challenges. With the SECM HITEC, a dual-clad fiber was used to reduce the speckle noise. Miniature GRIN optics was used to increase the NA of the fiber from 0.09 to 0.25, which made it possible to build a SECM capsule with large diameter (12.7 mm) while maintaining a short rigid length (22 mm). A water-immersion objective lens was custom designed and manufactured to provide high NA of 0.7. We have manufactured the SECM HITEC catheter and tested its optical and mechanical performance. Lateral and axial resolution was measured as 1.2 µm and 13 µm, respectively. We have imaged swine esophageal tissues ex vivo, and SECM images clearly visualized cell nuclei. Non-uniform rotational distortion (NURD) was small, less than 5%. Preliminary results suggest that SECM HITEC provides sufficient optical and mechanical performance for tissue imaging. In a future clinical study, we will test the feasibility of utilizing SECM HITEC for improved cellular imaging human of the human esophagus in vivo.

  15. Advanced Imaging Technologies for the Detection of Dysplasia and Early Cancer in Barrett Esophagus

    PubMed Central

    Espino, Alberto; Cirocco, Maria; DaCosta, Ralph

    2014-01-01

    Advanced esophageal adenocarcinomas arising from Barrett esophagus (BE) are tumors with an increasing incidence and poor prognosis. The aim of endoscopic surveillance of BE is to detect dysplasia, particularly high-grade dysplasia and intramucosal cancers that can subsequently be treated endoscopically before progression to invasive cancer with lymph node metastases. Current surveillance practice standards require the collection of random 4-quadrant biopsy specimens over every 1 to 2 cm of BE (Seattle protocol) to detect dysplasia with the assistance of white light endoscopy, in addition to performing targeted biopsies of recognizable lesions. This approach is labor-intensive but should currently be considered state of the art. Chromoendoscopy, virtual chromoendoscopy (e.g., narrow band imaging), and confocal laser endomicroscopy, in addition to high-definition standard endoscopy, might increase the diagnostic yield for the detection of dysplastic lesions. Until these modalities have been demonstrated to enhance efficiency or cost effectiveness, the standard protocol will remain careful examination using conventional off the shelf high-resolution endoscopes, combined with as longer inspection time which is associated with increased detection of dysplasia. PMID:24570883

  16. 3-D endoscopic imaging using plenoptic camera

    PubMed Central

    Le, Hanh N. D.; Decker, Ryan; Opferman, Justin; Kim, Peter; Krieger, Axel

    2017-01-01

    Three-dimensional endoscopic imaging using plenoptic technique combined with F-matching algorithm has been pursued in this study. A custom relay optics was designed to integrate a commercial surgical straight endoscope with a plenoptic camera. PMID:29276806

  17. A 3D photographic capsule endoscope system with full field of view

    NASA Astrophysics Data System (ADS)

    Ou-Yang, Mang; Jeng, Wei-De; Lai, Chien-Cheng; Kung, Yi-Chinn; Tao, Kuan-Heng

    2013-09-01

    Current capsule endoscope uses one camera to capture the surface image in the intestine. It can only observe the abnormal point, but cannot know the exact information of this abnormal point. Using two cameras can generate 3D images, but the visual plane changes while capsule endoscope rotates. It causes that two cameras can't capture the images information completely. To solve this question, this research provides a new kind of capsule endoscope to capture 3D images, which is 'A 3D photographic capsule endoscope system'. The system uses three cameras to capture images in real time. The advantage is increasing the viewing range up to 2.99 times respect to the two camera system. The system can accompany 3D monitor provides the exact information of symptom points, helping doctors diagnose the disease.

  18. Transparency-enhancing technology allows three-dimensional assessment of gastrointestinal mucosa: A porcine model.

    PubMed

    Mizutani, Hiroya; Ono, Satoshi; Ushiku, Tetsuo; Kudo, Yotaro; Ikemura, Masako; Kageyama, Natsuko; Yamamichi, Nobutake; Fujishiro, Mitsuhiro; Someya, Takao; Fukayama, Masashi; Koike, Kazuhiko; Onodera, Hiroshi

    2018-02-01

    Although high-resolution three-dimensional imaging of endoscopically resected gastrointestinal specimens can help elucidating morphological features of gastrointestinal mucosa or tumor, there are no established methods to achieve this without breaking specimens apart. We evaluated the utility of transparency-enhancing technology for three-dimensional assessment of gastrointestinal mucosa in porcine models. Esophagus, stomach, and colon mucosa samples obtained from a sacrificed swine were formalin-fixed and paraffin-embedded, and subsequently deparaffinized for analysis. The samples were fluorescently stained, optically cleared using transparency-enhancing technology: ilLUmination of Cleared organs to IDentify target molecules method (LUCID), and visualized using laser scanning microscopy. After observation, all specimens were paraffin-embedded again and evaluated by conventional histopathological assessment to measure the impact of transparency-enhancing procedures. As a result, microscopic observation revealed horizontal section views of mucosa at deeper levels and enabled the three-dimensional image reconstruction of glandular and vascular structures. Besides, paraffin-embedded specimens after transparency-enhancing procedures were all assessed appropriately by conventional histopathological staining. These results suggest that transparency-enhancing technology may be feasible for clinical application and enable the three-dimensional structural analysis of endoscopic resected specimen non-destructively. Although there remain many limitations or problems to be solved, this promising technology might represent a novel histopathological method for evaluating gastrointestinal cancers. © 2018 Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  19. Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo

    PubMed Central

    Liang, Kaicheng; Wang, Zhao; Ahsen, Osman O.; Lee, Hsiang-Chieh; Potsaid, Benjamin M.; Jayaraman, Vijaysekhar; Cable, Alex; Mashimo, Hiroshi; Li, Xingde; Fujimoto, James G.

    2018-01-01

    Devices that perform wide field-of-view (FOV) precision optical scanning are important for endoscopic assessment and diagnosis of luminal organ disease such as in gastroenterology. Optical scanning for in vivo endoscopic imaging has traditionally relied on one or more proximal mechanical actuators, limiting scan accuracy and imaging speed. There is a need for rapid and precise two-dimensional (2D) microscanning technologies to enable the translation of benchtop scanning microscopies to in vivo endoscopic imaging. We demonstrate a new cycloid scanner in a tethered capsule for ultrahigh speed, side-viewing optical coherence tomography (OCT) endomicroscopy in vivo. The cycloid capsule incorporates two scanners: a piezoelectrically actuated resonant fiber scanner to perform a precision, small FOV, fast scan and a micromotor scanner to perform a wide FOV, slow scan. Together these scanners distally scan the beam circumferentially in a 2D cycloid pattern, generating an unwrapped 1 mm × 38 mm strip FOV. Sequential strip volumes can be acquired with proximal pullback to image centimeter-long regions. Using ultrahigh speed 1.3 μm wavelength swept-source OCT at a 1.17 MHz axial scan rate, we imaged the human rectum at 3 volumes/s. Each OCT strip volume had 166 × 2322 axial scans with 8.5 μm axial and 30 μm transverse resolution. We further demonstrate OCT angiography at 0.5 volumes/s, producing volumetric images of vasculature. In addition to OCT applications, cycloid scanning promises to enable precision 2D optical scanning for other imaging modalities, including fluorescence confocal and nonlinear microscopy. PMID:29682598

  20. Endoscopic Optical Coherence Tomography for Clinical Gastroenterology

    PubMed Central

    Tsai, Tsung-Han; Fujimoto, James G.; Mashimo, Hiroshi

    2014-01-01

    Optical coherence tomography (OCT) is a real-time optical imaging technique that is similar in principle to ultrasonography, but employs light instead of sound waves and allows depth-resolved images with near-microscopic resolution. Endoscopic OCT allows the evaluation of broad-field and subsurface areas and can be used ancillary to standard endoscopy, narrow band imaging, chromoendoscopy, magnification endoscopy, and confocal endomicroscopy. This review article will provide an overview of the clinical utility of endoscopic OCT in the gastrointestinal tract and of recent achievements using state-of-the-art endoscopic 3D-OCT imaging systems. PMID:26852678

  1. In vivo endoscopic Doppler optical coherence tomography imaging of the colon

    PubMed Central

    Welge, Weston A.; Barton, Jennifer K.

    2017-01-01

    Background and Objective Colorectal cancer remains the second deadliest cancer in the United States. Several screening methods exist, however detection of small polyps remains a challenge. Optical coherence tomography has been demonstrated to be capable of detecting lesions as small as 1 mm in the mouse colon, but detection is based on measuring a doubling of the mucosa thickness. The colon microvasculature may be an attractive biomarker of early tumor development because tumor vessels are characterized by irregular structure and dysfunction. Our goal was to develop an endoscopic method of detecting and segmenting colon vessels using Doppler optical coherence tomography to enable future studies for improving early detection and development of novel chemopreventive agents. Method We conducted in vivo colon imaging in an azoxymethane (AOM)-treated mouse model of colorectal cancer using a miniature endoscope and a swept-source OCT system at 1040 nm with a 16 kHz sweep rate. We applied the Kasai autocorrelation algorithm to laterally oversampled OCT B-scans to resolve vascular flow in the mucosa and submucosa. Vessels were segmented by applying a series of image processing steps: (1) intensity thresholding, (2) two-dimensional matched filtering, and (3) histogram segmentation. Results We observed differences in the vessels sizes and spatial distribution in a mature adenoma compared to surrounding undiseased tissue and compared the results with histology. We also imaged flow in four young mice (2 AOM-treated and 2 control) showing no significant differences, which is expected so early after carcinogen exposure. We also present flow images of adenoma in a living mouse and a euthanized mouse to demonstrate that no flow is detected after euthanasia. Conclusion We present, to the best of our knowledge, the first Doppler OCT images of in vivo mouse colon collected with a fiber-based endoscope. We also describe a fast and robust image processing method for segmenting vessels in the colon. These results suggest that Doppler OCT is a promising imaging modality for vascular imaging in the colon that requires no exogenous contrast agents. PMID:27546786

  2. First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: electric-field propagation.

    PubMed

    Bang, Seungmin; Park, Jeong Youp; Jeong, Seok; Kim, Young Ho; Shim, Han Bo; Kim, Tae Song; Lee, Don Haeng; Song, Si Young

    2009-02-01

    We developed a capsule endoscope (CE), "MiRo," with the novel transmission technology of electric-field propagation. The technology uses the human body as a conductive medium for data transmission. Specifications of the prototype include the ability to receive real-time images; size, 10.8 x 24 mm; weight, 3.3 g; field of view, 150 degrees; resolution of power, 320 x 320 pixels; and transmittal speed, 2 frames per second. To evaluate the clinical safety and diagnostic feasibility of the prototype MiRo, we conducted a multicenter clinical trial. All volunteers underwent baseline examinations, including EGD and electrocardiography for the screening of GI obstructive and cardiovascular diseases, before the trial. In the first 10 cases, 24-hour Holter monitoring was also performed. To evaluate the diagnostic feasibility, transmission rate of the captured images, inspection rate of the entire small bowel, and quality of transmitted images (graded as outstanding, excellent, good/average, below average, and poor) were analyzed. Of the 49 healthy volunteers, 45 were included in the trial, and 4 were excluded because of baseline abnormalities. No adverse effects were noted. All CEs were expelled within 2 days, and the entire small bowel could be explored in all cases. The transmission rates of the captured image in the stomach, small bowel, and colon were 99.5%, 99.6%, and 97.2%, respectively. The mean total duration of image transmission was 9 hours, 51 minutes, and the mean transit time of the entire small bowel was 4 hours, 33 minutes. Image quality was graded as good or better in 41 cases (91.1%). Details of the villi and vascular structures of the entire small bowel were clearly visualized in 31 cases (68.9%). MiRo is safe and effective for exploring the entire small bowel, with good image quality and real-time feasibility. This novel transmission technology may have applications beyond the field of capsule endoscopy.

  3. Endoscopic techniques in aesthetic plastic surgery.

    PubMed

    McCain, L A; Jones, G

    1995-01-01

    There has been an explosive interest in endoscopic techniques by plastic surgeons over the past two years. Procedures such as facial rejuvenation, breast augmentation and abdominoplasty are being performed with endoscopic assistance. Endoscopic operations require a complex setup with components such as video camera, light sources, cables and hard instruments. The Hopkins Rod Lens system consists of optical fibers for illumination, an objective lens, an image retrieval system, a series of rods and lenses, and an eyepiece for image collection. Good illumination of the body cavity is essential for endoscopic procedures. Placement of the video camera on the eyepiece of the endoscope gives a clear, brightly illuminated large image on the monitor. The video monitor provides the surgical team with the endoscopic image. It is important to become familiar with the equipment before actually doing cases. Several options exist for staff education. In the operating room the endoscopic cart needs to be positioned to allow a clear unrestricted view of the video monitor by the surgeon and the operating team. Fogging of the endoscope may be prevented during induction by using FREDD (a fog reduction/elimination device) or a warm bath. The camera needs to be white balanced. During the procedure, the nurse monitors the level of dissection and assesses for clogging of the suction.

  4. Volume holographic reflection endoscope for in-vivo ovarian cancer clinical studies

    NASA Astrophysics Data System (ADS)

    Howlett, I. D.; Gordon, M.; Brownlee, J. W.; Barton, J. K.; Kostuk, R. K.

    2014-03-01

    We present the design for an endoscopic system capable of imaging tissues of the ovary at two selected imaging depths simultaneously. The method utilizes a multiplexed volume hologram to select wavefronts from different depths within the tissue. It is the first demonstration of an endoscopic volume holographic imaging system. The endoscope uses both gradient index (GRIN) optical components and off the shelf singlet lenses to relay an image from the distal tip to the proximal end. The endoscope has a minimum diameter of 3.75 mm. The system length is 30 cm which is connected to a handle that includes the holographic components and optics that relay the image to a camera. Preliminary evaluation of the endoscope was performed with tissue phantoms and calibrated targets, which shows lateral resolution ≍ 4 μm at an operating wavelength of 660 nm. The hologram is recorded in phenanthraquinone doped poly methacrylate and is designed to produce images from two tissue depths. One image is obtained at the tissue surface and the second 70 μm below the surface. This method requires no mechanical scanning and acquires an image at the camera frame rate. The preliminary ex-vivo results show good correlation with histology sections of the same tissue sections.

  5. Hybrid model based unified scheme for endoscopic Cerenkov and radio-luminescence tomography: Simulation demonstration

    NASA Astrophysics Data System (ADS)

    Wang, Lin; Cao, Xin; Ren, Qingyun; Chen, Xueli; He, Xiaowei

    2018-05-01

    Cerenkov luminescence imaging (CLI) is an imaging method that uses an optical imaging scheme to probe a radioactive tracer. Application of CLI with clinically approved radioactive tracers has opened an opportunity for translating optical imaging from preclinical to clinical applications. Such translation was further improved by developing an endoscopic CLI system. However, two-dimensional endoscopic imaging cannot identify accurate depth and obtain quantitative information. Here, we present an imaging scheme to retrieve the depth and quantitative information from endoscopic Cerenkov luminescence tomography, which can also be applied for endoscopic radio-luminescence tomography. In the scheme, we first constructed a physical model for image collection, and then a mathematical model for characterizing the luminescent light propagation from tracer to the endoscopic detector. The mathematical model is a hybrid light transport model combined with the 3rd order simplified spherical harmonics approximation, diffusion, and radiosity equations to warrant accuracy and speed. The mathematical model integrates finite element discretization, regularization, and primal-dual interior-point optimization to retrieve the depth and the quantitative information of the tracer. A heterogeneous-geometry-based numerical simulation was used to explore the feasibility of the unified scheme, which demonstrated that it can provide a satisfactory balance between imaging accuracy and computational burden.

  6. A beam-splitter-type 3-D endoscope for front view and front-diagonal view images.

    PubMed

    Kamiuchi, Hiroki; Masamune, Ken; Kuwana, Kenta; Dohi, Takeyoshi; Kim, Keri; Yamashita, Hiromasa; Chiba, Toshio

    2013-01-01

    In endoscopic surgery, surgeons must manipulate an endoscope inside the body cavity to observe a large field-of-view while estimating the distance between surgical instruments and the affected area by reference to the size or motion of the surgical instruments in 2-D endoscopic images on a monitor. Therefore, there is a risk of the endoscope or surgical instruments physically damaging body tissues. To overcome this problem, we developed a Ø7- mm 3-D endoscope that can switch between providing front and front-diagonal view 3-D images by simply rotating its sleeves. This 3-D endoscope consists of a conventional 3-D endoscope and an outer and inner sleeve with a beam splitter and polarization plates. The beam splitter was used for visualizing both the front and front-diagonal view and was set at 25° to the outer sleeve's distal end in order to eliminate a blind spot common to both views. Polarization plates were used to avoid overlap of the two views. We measured signal-to-noise ratio (SNR), sharpness, chromatic aberration (CA), and viewing angle of this 3-D endoscope and evaluated its feasibility in vivo. Compared to the conventional 3-D endoscope, SNR and sharpness of this 3-D endoscope decreased by 20 and 7 %, respectively. No significant difference was found in CA. The viewing angle for both the front and front-diagonal views was about 50°. In the in vivo experiment, this 3-D endoscope can provide clear 3-D images of both views by simply rotating its inner sleeve. The developed 3-D endoscope can provide the front and front-diagonal view by simply rotating the inner sleeve, therefore the risk of damage to fragile body tissues can be significantly decreased.

  7. Center for Integration of Medicine and Innovative Technology. Addendum

    DTIC Science & Technology

    2009-10-01

    development in biomaterials , endoscopic tools, energy delivery, medical imaging, and other novel technologies. 15. SUBJECT TERMS None provided. 16. SECURITY...below. Issues of Concern We have identified a suitable colla borator to conclude the second an d final phase of this project, namely Dr. Gary...patent application will depend on the results of the second phase of t he project, as well as the ex isting int ellectual property on SEE-fitted

  8. Dynamic focus-tracking MEMS scanning micromirror with low actuation voltages for endoscopic imaging

    PubMed Central

    Strathman, Matthew; Liu, Yunbo; Li, Xingde; Lin, Lih Y.

    2013-01-01

    We demonstrate a 3-D scanning micromirror device that combines 2-D beam scanning with focus control in the same device using micro-electro-mechanical-systems (MEMS) technology. 2-D beam scanning is achieved with a biaxial gimbal structure and focus control is obtained with a deformable mirror membrane surface. The micromirror with 800 micrometer diameter is designed to be sufficiently compact and efficient so that it can be incorporated into an endoscopic imaging probe in the future. The design, fabrication and characterization of the device are described in this paper. Using the focus-tracking MEMS scanning mirror, we achieved an optical scanning range of >16 degrees with <40 V actuation voltage at resonance and a tunable focal length between infinity and 25 mm with <100V applied bias. PMID:24104304

  9. Duodenal endoscopic findings and histopathologic confirmation of intestinal lymphangiectasia in dogs.

    PubMed

    Larson, R N; Ginn, J A; Bell, C M; Davis, M J; Foy, D S

    2012-01-01

    The diagnosis of intestinal lymphangiectasia (IL) has been associated with characteristic duodenal mucosal changes. However, the sensitivity and specificity of the endoscopic duodenal mucosal appearance for the diagnosis of IL are not reported. To evaluate the utility of endoscopic images of the duodenum for diagnosis of IL. Endoscopic appearance of the duodenal mucosal might predict histopathologic diagnosis of IL with a high degree of sensitivity and specificity. 51 dogs that underwent upper gastrointestinal (GI) endoscopy and endoscopic biopsies. Retrospective review of images acquired during endoscopy. Dogs were included if adequate biopsies were obtained during upper GI endoscopy and digital images were saved during the procedure. Images were assessed for the presence and severity of IL. Using histopathology as the gold standard, the sensitivity and specificity of endoscopy for diagnosing IL were calculated. Intestinal lymphangiectasia (IL) was diagnosed in 25/51 dogs. Gross endoscopic appearance of the duodenal mucosa had a sensitivity and specificity (95% confidence interval) of 68% (46%, 84%) and 42% (24%, 63%), respectively for diagnosis of IL. Endoscopic images in cases with lymphopenia, hypocholesterolemia, and hypoalbuminemia had a sensitivity of 80%. Endoscopic duodenal mucosa appearance alone lacks specificity and has only a moderate sensitivity for diagnosis of IL. Evaluation of biomarkers associated with PLE improved the sensitivity; however, poor specificity for diagnosis of IL supports the need for histopathologic confirmation. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  10. Simple, monolithic optical element for forward-viewing spectrally encoded endoscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Do, Dukho; Kang, Dongkyun; Ikuta, Mitsuhiro; Tearney, Guillermo J.

    2016-03-01

    Spectrally encoded endoscopy (SEE) is a miniature endoscopic technology that can acquire images of internal organs through a hair-thin probe. While most previously described SEE probes have been side viewing, forward-view (FV)-SEE is advantageous in certain clinical applications as it provides more natural navigation of the probe and has the potential to provide a wider field of view. Prior implementations of FV-SEE used multiple optical elements that increase fabrication complexity and may diminish the robustness of the device. In this paper, we present a new design that uses a monolithic optical element to realize FV-SEE imaging. The optical element is specially designed spacer, fabricated from a 500-μm-glass rod that has a mirror surface on one side and a grating stamped on its distal end. The mirror surface is used to change the incident angle on the grating to diffract the shortest wavelength of the spectrum so that it is parallel to the optical axis. Rotating the SEE optics creates a circular FV-SEE image. Custom-designed software processes FV-SEE images into circular images, which are displayed in real-time. In order to demonstrate this new design, we have constructed the FV-SEE optical element using a 1379 lines/mm diffraction grating. When illuminated with a source with a spectral bandwidth of 420-820 nm, the FV-SEE optical element provides 678 resolvable points per line. The imaging performance of the FV-SEE device was tested by imaging a USAF resolution target. SEE images showed that this new approach generates high quality images in the forward field with a field of view of 58°. Results from this preliminary study demonstrate that we can realize FV-SEE imaging with simple, monolithic, miniature optical element. The characteristics of this FV-SEE configuration will facilitate the development of robust miniature endoscopes for a variety of medical imaging applications.

  11. In vivo endoscopic Doppler optical coherence tomography imaging of mouse colon

    NASA Astrophysics Data System (ADS)

    Welge, Weston A.; Barton, Jennifer K.

    2016-03-01

    Colorectal cancer remains the second deadliest cancer in the United States, despite the high sensitivity and specificity of colonoscopy and sigmoidoscopy. While these standard imaging procedures can accurately detect medium and large polyps, some studies have shown miss rates up to 25% for polyps less than 5 mm in diameter. An imaging modality capable of detecting small lesions could potentially improve patient outcomes. Optical coherence tomography (OCT) has been shown to be a powerful imaging modality for adenoma detection in a mouse model of colorectal cancer. While previous work has focused on analyzing the structural OCT images based on thickening of the mucosa and changes in light attenuation in depth, imaging the microvasculature of the colon may enable earlier detection of polyps. The structure and function of vessels grown to support tumor growth are markedly different from healthy vessels. Doppler OCT is capable of imaging microvessels in vivo. We developed a method of processing raw fringe data from a commercial swept-source OCT system using a lab-built miniature endoscope to extract microvessels. This method can be used to measure vessel count and density and to measure flow velocities. This may improve early detection and aid in the development of new chemopreventive and chemotherapeutic drugs. We present, to the best of our knowledge, the first endoscopic Doppler OCT images of in vivo mouse colon.

  12. Quantitative Evaluation of Adult Subglottic Stenosis Using Intraoperative Long-range Optical Coherence Tomography

    PubMed Central

    Sharma, Giriraj K.; Loy, Anthony Chin; Su, Erica; Jing, Joe; Chen, Zhongping; Wong, Brian J-F.; Verma, Sunil

    2016-01-01

    Objectives To determine the feasibility of long-range optical coherence tomography (LR-OCT) as a tool to intraoperatively image and measure the subglottis and trachea during suspension microlaryngoscopy before and after endoscopic treatment of subglottic stenosis (SGS). Methods Long-range optical coherence tomography of the adult subglottis and trachea was performed during suspension microlaryngoscopy before and after endoscopic treatment for SGS. The anteroposterior and transverse diameters, cross-sectional area (CSA), distance from the vocal cords, and length of the SGS were measured using a MATLAB software. Pre-intervention and postintervention airway dimensions were compared. Three-dimensional volumetric airway reconstructions were generated using medical image processing software (MIMICS). Results Intraoperative LR-OCT imaging was performed in 3 patients undergoing endoscopic management of SGS. Statistically significant differences in mean anteroposterior diameter (P < .01), transverse diameter (P < .001), and CSA (P < .001) were noted between pre-intervention and postintervention data. Three-dimensional airway models were viewed in cross-sectional format and via virtual “fly through” bronchoscopy. Conclusions This is the first report of intraoperative LR-OCT of the subglottic and tracheal airway before and after surgical management of SGS in humans. Long-range optical coherence tomography offers a practical means to measure the dimensions of SGS and acquire objective data on the response to endoscopic treatment of SGS. PMID:27354215

  13. Laser induced fluorescence as a diagnostic tool integrated into a scanning fiber endoscope for mouse imaging

    NASA Astrophysics Data System (ADS)

    Brown, Christopher M.; Maggio-Price, Lillian; Seibel, Eric J.

    2007-02-01

    Scanning fiber endoscope (SFE) technology has shown promise as a minimally invasive optical imaging tool. To date, it is capable of capturing full-color 500-line images, at 15 Hz frame rate in vivo, as a 1.6 mm diameter endoscope. The SFE uses a singlemode optical fiber actuated at mechanical resonance to scan a light spot over tissue while backscattered or fluorescent light at each pixel is detected in time series using several multimode optical fibers. We are extending the capability of the SFE from a RGB reflectance imaging device to a diagnostic tool by imaging laser induced fluorescence (LIF) in tissue, allowing for correlation of endogenous fluorescence to tissue state. Design of the SFE for diagnostic imaging is guided by a comparison of single point spectra acquired from an inflammatory bowel disease (IBD) model to tissue histology evaluated by a pathologist. LIF spectra were acquired by illuminating tissue with a 405 nm light source and detecting intrinsic fluorescence with a multimode optical fiber. The IBD model used in this study was mdr1a-/- mice, where IBD was modulated by infection with Helicobacter bilis. IBD lesions in the mouse model ranged from mild to marked hyperplasia and dysplasia, from the distal colon to the cecum. A principle components analysis (PCA) was conducted on single point spectra of control and IBD tissue. PCA allowed for differentiation between healthy and dysplastic tissue, indicating that emission wavelengths from 620 - 650 nm were best able to differentiate diseased tissue and inflammation from normal healthy tissue.

  14. A feasibility study of an integrated NIR/gamma/visible imaging system for endoscopic sentinel lymph node mapping.

    PubMed

    Kang, Han Gyu; Lee, Ho-Young; Kim, Kyeong Min; Song, Seong-Hyun; Hong, Gun Chul; Hong, Seong Jong

    2017-01-01

    The aim of this study is to integrate NIR, gamma, and visible imaging tools into a single endoscopic system to overcome the limitation of NIR using gamma imaging and to demonstrate the feasibility of endoscopic NIR/gamma/visible fusion imaging for sentinel lymph node (SLN) mapping with a small animal. The endoscopic NIR/gamma/visible imaging system consists of a tungsten pinhole collimator, a plastic focusing lens, a BGO crystal (11 × 11 × 2 mm 3 ), a fiber-optic taper (front = 11 × 11 mm 2 , end = 4 × 4 mm 2 ), a 122-cm long endoscopic fiber bundle, an NIR emission filter, a relay lens, and a CCD camera. A custom-made Derenzo-like phantom filled with a mixture of 99m Tc and indocyanine green (ICG) was used to assess the spatial resolution of the NIR and gamma images. The ICG fluorophore was excited using a light-emitting diode (LED) with an excitation filter (723-758 nm), and the emitted fluorescence photons were detected with an emission filter (780-820 nm) for a duration of 100 ms. Subsequently, the 99m Tc distribution in the phantom was imaged for 3 min. The feasibility of in vivo SLN mapping with a mouse was investigated by injecting a mixture of 99m Tc-antimony sulfur colloid (12 MBq) and ICG (0.1 mL) into the right paw of the mouse (C57/B6) subcutaneously. After one hour, NIR, gamma, and visible images were acquired sequentially. Subsequently, the dissected SLN was imaged in the same way as the in vivo SLN mapping. The NIR, gamma, and visible images of the Derenzo-like phantom can be obtained with the proposed endoscopic imaging system. The NIR/gamma/visible fusion image of the SLN showed a good correlation among the NIR, gamma, and visible images both for the in vivo and ex vivo imaging. We demonstrated the feasibility of the integrated NIR/gamma/visible imaging system using a single endoscopic fiber bundle. In future, we plan to investigate miniaturization of the endoscope head and simultaneous NIR/gamma/visible imaging with dichroic mirrors and three CCD cameras. © 2016 American Association of Physicists in Medicine.

  15. A high definition Mueller polarimetric endoscope for tissue characterisation (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Qi, Ji; Elson, Daniel

    2016-03-01

    The mechanism of most medical endoscopes is based on the interaction between light and biological tissue, inclusive of absorption, elastic scattering and fluorescence. In essence, the metrics of those interactions are obtained from the fundamental properties of light as an electro-magnetic waves, namely, the radiation intensity and wavelength. As another fundamental property of light, polarisation can not only reveal tissue scattering and absorption information from a different perspective, but is also able to provide a fresh insight into directional tissue birefringence properties induced by birefringent compositions and anisotropic fibrous structures, such as collagen, elastin, muscle fibre, etc at the same time. Here we demonstrate a low cost high definition Muller polarimetric endoscope with minimal alteration of a rigid endoscope. By imaging birefringent tissue mimicking phantoms and a porcine bladder, we show that this novel endoscopic imaging modality is able to provide different information of interest from unpolarised endoscopic imaging, including linear depolarization, circular depolarization, birefringence, optic axis orientation and dichroism. This endoscope can potentially be employed for better tissue visualisation and benefit endoscopic investigations and intra-operative guidance.

  16. Optical coherence tomography in gastroenterology: a review and future outlook

    NASA Astrophysics Data System (ADS)

    Tsai, Tsung-Han; Leggett, Cadman L.; Trindade, Arvind J.; Sethi, Amrita; Swager, Anne-Fré; Joshi, Virendra; Bergman, Jacques J.; Mashimo, Hiroshi; Nishioka, Norman S.; Namati, Eman

    2017-12-01

    Optical coherence tomography (OCT) is an imaging technique optically analogous to ultrasound that can generate depth-resolved images with micrometer-scale resolution. Advances in fiber optics and miniaturized actuation technologies allow OCT imaging of the human body and further expand OCT utilization in applications including but not limited to cardiology and gastroenterology. This review article provides an overview of current OCT development and its clinical utility in the gastrointestinal tract, including disease detection/differentiation and endoscopic therapy guidance, as well as a discussion of its future applications.

  17. Endoscopic Management of Early Adenocarcinoma and Squamous Cell Carcinoma of the Esophagus: Screening, Diagnosis, and Therapy.

    PubMed

    di Pietro, Massimiliano; Canto, Marcia I; Fitzgerald, Rebecca C

    2018-01-01

    Because the esophagus is easily accessible with endoscopy, early diagnosis and curative treatment of esophageal cancer is possible. However, diagnosis is often delayed because symptoms are not specific during early stages of tumor development. The onset of dysphagia is associated with advanced disease, which has a survival at 5 years lower than 15%. Population screening by endoscopy is not cost-effective, but a number of alternative imaging and cell analysis technologies are under investigation. The ideal screening test should be inexpensive, well tolerated, and applicable to primary care. Over the past 10 years, significant progress has been made in endoscopic diagnosis and treatment of dysplasia (squamous and Barrett's), and early esophageal cancer using resection and ablation technologies supported by evidence from randomized controlled trials. We review the state-of-the-art technologies for early diagnosis and minimally invasive treatment, which together could reduce the burden of disease. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  18. New endoscopy advances to refine adenoma detection rate for colorectal cancer screening: None is the winner.

    PubMed

    Maida, Marcello; Camilleri, Salvatore; Manganaro, Michele; Garufi, Serena; Scarpulla, Giuseppe

    2017-10-15

    Colorectal cancer (CRC) is the third most common cancer in males and second in females, and globally the fourth cause for cancer death worldwide. Oncological screening of CRC has a major role in the management of the disease and it is mostly performed by colonoscopy. Anyway, effectiveness of endoscopic screening for CRC strictly depends on adequate detection and removal of potentially precancerous lesions, and accuracy of colonoscopy in detection of adenomas is still suboptimal. For this reason, several technological advances have been implemented in order to improve the diagnostic sensitivity of colonoscopy in adenoma detection. Among these: (1) Visual technologies such as chromoendoscopy and narrow band imaging; (2) optical innovation as high definition endoscopy, full-spectrum endoscopy or Third Eye Retroscope; and (3) mechanical advances as Cap assisted colonoscopy, Endocuff, Endoring and G-Eye endoscope. All these technologies advances have been tested over time by clinical studies with mixed results. Which of them is more likely to be successful in the next future?

  19. Targeted Endoscopic Imaging

    PubMed Central

    Li, Meng; Wang, Thomas D

    2011-01-01

    Summary Endoscopy has undergone explosive technological growth in over recent years, and with the emergence of targeted imaging, its truly transformative power and impact in medicine lies just over the horizon. Today, our ability to see inside the digestive tract with medical endoscopy is headed toward exciting crossroads. The existing paradigm of making diagnostic decisions based on observing structural changes and identifying anatomical landmarks may soon be replaced by visualizing functional properties and imaging molecular expression. In this novel approach, the presence of intracellular and cell surface targets unique to disease are identified and used to predict the likelihood of mucosal transformation and response to therapy. This strategy can result in the development of new methods for early cancer detection, personalized therapy, and chemoprevention. This targeted approach will require further development of molecular probes and endoscopic instruments, and will need support from the FDA for streamlined regulatory oversight. Overall, this molecular imaging modality promises to significantly broaden the capabilities of the gastroenterologist by providing a new approach to visualize the mucosa of the digestive tract in a manner that has never been seen before. PMID:19423025

  20. Evolution of stereoscopic imaging in surgery and recent advances

    PubMed Central

    Schwab, Katie; Smith, Ralph; Brown, Vanessa; Whyte, Martin; Jourdan, Iain

    2017-01-01

    In the late 1980s the first laparoscopic cholecystectomies were performed prompting a sudden rise in technological innovations as the benefits and feasibility of minimal access surgery became recognised. Monocular laparoscopes provided only two-dimensional (2D) viewing with reduced depth perception and contributed to an extended learning curve. Attention turned to producing a usable three-dimensional (3D) endoscopic view for surgeons; utilising different technologies for image capture and image projection. These evolving visual systems have been assessed in various research environments with conflicting outcomes of success and usability, and no overall consensus to their benefit. This review article aims to provide an explanation of the different types of technologies, summarise the published literature evaluating 3D vs 2D laparoscopy, to explain the conflicting outcomes, and discuss the current consensus view. PMID:28874957

  1. 2D and 3D visualization methods of endoscopic panoramic bladder images

    NASA Astrophysics Data System (ADS)

    Behrens, Alexander; Heisterklaus, Iris; Müller, Yannick; Stehle, Thomas; Gross, Sebastian; Aach, Til

    2011-03-01

    While several mosaicking algorithms have been developed to compose endoscopic images of the internal urinary bladder wall into panoramic images, the quantitative evaluation of these output images in terms of geometrical distortions have often not been discussed. However, the visualization of the distortion level is highly desired for an objective image-based medical diagnosis. Thus, we present in this paper a method to create quality maps from the characteristics of transformation parameters, which were applied to the endoscopic images during the registration process of the mosaicking algorithm. For a global first view impression, the quality maps are laid over the panoramic image and highlight image regions in pseudo-colors according to their local distortions. This illustration supports then surgeons to identify geometrically distorted structures easily in the panoramic image, which allow more objective medical interpretations of tumor tissue in shape and size. Aside from introducing quality maps in 2-D, we also discuss a visualization method to map panoramic images onto a 3-D spherical bladder model. Reference points are manually selected by the surgeon in the panoramic image and the 3-D model. Then the panoramic image is mapped by the Hammer-Aitoff equal-area projection onto the 3-D surface using texture mapping. Finally the textured bladder model can be freely moved in a virtual environment for inspection. Using a two-hemisphere bladder representation, references between panoramic image regions and their corresponding space coordinates within the bladder model are reconstructed. This additional spatial 3-D information thus assists the surgeon in navigation, documentation, as well as surgical planning.

  2. Augmented reality to the rescue of the minimally invasive surgeon. The usefulness of the interposition of stereoscopic images in the Da Vinci™ robotic console.

    PubMed

    Volonté, Francesco; Buchs, Nicolas C; Pugin, François; Spaltenstein, Joël; Schiltz, Boris; Jung, Minoa; Hagen, Monika; Ratib, Osman; Morel, Philippe

    2013-09-01

    Computerized management of medical information and 3D imaging has become the norm in everyday medical practice. Surgeons exploit these emerging technologies and bring information previously confined to the radiology rooms into the operating theatre. The paper reports the authors' experience with integrated stereoscopic 3D-rendered images in the da Vinci surgeon console. Volume-rendered images were obtained from a standard computed tomography dataset using the OsiriX DICOM workstation. A custom OsiriX plugin was created that permitted the 3D-rendered images to be displayed in the da Vinci surgeon console and to appear stereoscopic. These rendered images were displayed in the robotic console using the TilePro multi-input display. The upper part of the screen shows the real endoscopic surgical field and the bottom shows the stereoscopic 3D-rendered images. These are controlled by a 3D joystick installed on the console, and are updated in real time. Five patients underwent a robotic augmented reality-enhanced procedure. The surgeon was able to switch between the classical endoscopic view and a combined virtual view during the procedure. Subjectively, the addition of the rendered images was considered to be an undeniable help during the dissection phase. With the rapid evolution of robotics, computer-aided surgery is receiving increasing interest. This paper details the authors' experience with 3D-rendered images projected inside the surgical console. The use of this intra-operative mixed reality technology is considered very useful by the surgeon. It has been shown that the usefulness of this technique is a step toward computer-aided surgery that will progress very quickly over the next few years. Copyright © 2012 John Wiley & Sons, Ltd.

  3. Hyperspectral imaging fluorescence excitation scanning for colon cancer detection

    NASA Astrophysics Data System (ADS)

    Leavesley, Silas J.; Walters, Mikayla; Lopez, Carmen; Baker, Thomas; Favreau, Peter F.; Rich, Thomas C.; Rider, Paul F.; Boudreaux, Carole W.

    2016-10-01

    Optical spectroscopy and hyperspectral imaging have shown the potential to discriminate between cancerous and noncancerous tissue with high sensitivity and specificity. However, to date, these techniques have not been effectively translated to real-time endoscope platforms. Hyperspectral imaging of the fluorescence excitation spectrum represents new technology that may be well suited for endoscopic implementation. However, the feasibility of detecting differences between normal and cancerous mucosa using fluorescence excitation-scanning hyperspectral imaging has not been evaluated. The goal of this study was to evaluate the initial feasibility of using fluorescence excitation-scanning hyperspectral imaging for measuring changes in fluorescence excitation spectrum concurrent with colonic adenocarcinoma using a small pre-pilot-scale sample size. Ex vivo analysis was performed using resected pairs of colorectal adenocarcinoma and normal mucosa. Adenocarcinoma was confirmed by histologic evaluation of hematoxylin and eosin (H&E) permanent sections. Specimens were imaged using a custom hyperspectral imaging fluorescence excitation-scanning microscope system. Results demonstrated consistent spectral differences between normal and cancerous tissues over the fluorescence excitation range of 390 to 450 nm that could be the basis for wavelength-dependent detection of colorectal cancers. Hence, excitation-scanning hyperspectral imaging may offer an alternative approach for discriminating adenocarcinoma from surrounding normal colonic mucosa, but further studies will be required to evaluate the accuracy of this approach using a larger patient cohort.

  4. Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight.

    PubMed

    Jones, J A; Johnston, S; Campbell, M; Miles, B; Billica, R

    1999-05-01

    The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

  5. Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight

    NASA Technical Reports Server (NTRS)

    Jones, J. A.; Johnston, S.; Campbell, M.; Miles, B.; Billica, R.

    1999-01-01

    OBJECTIVES: The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. METHODS: A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). RESULTS: The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. CONCLUSIONS: In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

  6. An Insect Eye Inspired Miniaturized Multi-Camera System for Endoscopic Imaging.

    PubMed

    Cogal, Omer; Leblebici, Yusuf

    2017-02-01

    In this work, we present a miniaturized high definition vision system inspired by insect eyes, with a distributed illumination method, which can work in dark environments for proximity imaging applications such as endoscopy. Our approach is based on modeling biological systems with off-the-shelf miniaturized cameras combined with digital circuit design for real time image processing. We built a 5 mm radius hemispherical compound eye, imaging a 180 ° ×180 ° degrees field of view while providing more than 1.1 megapixels (emulated ommatidias) as real-time video with an inter-ommatidial angle ∆ϕ = 0.5 ° at 18 mm radial distance. We made an FPGA implementation of the image processing system which is capable of generating 25 fps video with 1080 × 1080 pixel resolution at a 120 MHz processing clock frequency. When compared to similar size insect eye mimicking systems in literature, the system proposed in this paper features 1000 × resolution increase. To the best of our knowledge, this is the first time that a compound eye with built-in illumination idea is reported. We are offering our miniaturized imaging system for endoscopic applications like colonoscopy or laparoscopic surgery where there is a need for large field of view high definition imagery. For that purpose we tested our system inside a human colon model. We also present the resulting images and videos from the human colon model in this paper.

  7. Advanced Endoscopic Navigation: Surgical Big Data, Methodology, and Applications.

    PubMed

    Luo, Xiongbiao; Mori, Kensaku; Peters, Terry M

    2018-06-04

    Interventional endoscopy (e.g., bronchoscopy, colonoscopy, laparoscopy, cystoscopy) is a widely performed procedure that involves either diagnosis of suspicious lesions or guidance for minimally invasive surgery in a variety of organs within the body cavity. Endoscopy may also be used to guide the introduction of certain items (e.g., stents) into the body. Endoscopic navigation systems seek to integrate big data with multimodal information (e.g., computed tomography, magnetic resonance images, endoscopic video sequences, ultrasound images, external trackers) relative to the patient's anatomy, control the movement of medical endoscopes and surgical tools, and guide the surgeon's actions during endoscopic interventions. Nevertheless, it remains challenging to realize the next generation of context-aware navigated endoscopy. This review presents a broad survey of various aspects of endoscopic navigation, particularly with respect to the development of endoscopic navigation techniques. First, we investigate big data with multimodal information involved in endoscopic navigation. Next, we focus on numerous methodologies used for endoscopic navigation. We then review different endoscopic procedures in clinical applications. Finally, we discuss novel techniques and promising directions for the development of endoscopic navigation.

  8. Towards non-contact photo-acoustic endoscopy using speckle pattern analysis

    NASA Astrophysics Data System (ADS)

    Lengenfelder, Benjamin; Mehari, Fanuel; Tang, Yuqi; Klämpfl, Florian; Zalevsky, Zeev; Schmidt, Michael

    2017-03-01

    Photoacoustic Tomography combines the advantages of optical and acoustic imaging as it makes use of the high optical contrast of tissue and the high resolution of ultrasound. Furthermore, high penetration depths in tissue in the order of several centimeters can be achieved by the combination of these modalities. Extensive research is being done in the field of miniaturization of photoacoustic devices, as photoacoustic imaging could be of significant benefits for the physician during endoscopic interventions. All the existing miniature systems are based on contact transducers for signal detection that are placed at the distal end of an endoscopic device. This makes the manufacturing process difficult and impedance matching to the inspected surface a requirement. The requirement for contact limits the view of the physician during the intervention. Consequently, a fiber based non-contact optical sensing technique would be highly beneficial for the development of miniaturized photoacoustic endoscopic devices. This work demonstrates the feasibility of surface displacement detection using remote speckle-sensing using a high speed camera and an imaging fiber bundle that is used in commercially available video endoscopes. The feasibility of displacement sensing is demonstrated by analysis of phantom vibrations which are induced by loudspeaker membrane oscillations. Since the usability of the remote speckle-sensing for photo-acoustic signal detection was already demonstrated, the fiber bundle approach demonstrates the potential for non-contact photoacoustic detections during endoscopy.

  9. Performance evaluation of stereo endoscopic imaging system incorporating TFT-LCD.

    PubMed

    Song, C-G; Park, S-K

    2005-01-01

    This paper presents a 3D endoscopic video system designed to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. In a comparison of the polarized and electric shutter-type stereo imaging systems, the former was found to be superior in terms of both accuracy and speed for knot-tying and for the loop pass test. The results of our experiments show that the proposed 3D endoscopic system has a sufficiently wide viewing angle and zone for multi-viewing, and that it provides better image quality and more stable optical performance compared with the electric shutter-type.

  10. Adjustable-Viewing-Angle Endoscopic Tool for Skull Base and Brain Surgery

    NASA Technical Reports Server (NTRS)

    Bae, Youngsam; Liao, Anna; Manohara, Harish; Shahinian, Hrayr

    2008-01-01

    The term Multi-Angle and Rear Viewing Endoscopic tooL (MARVEL) denotes an auxiliary endoscope, now undergoing development, that a surgeon would use in conjunction with a conventional endoscope to obtain additional perspective. The role of the MARVEL in endoscopic brain surgery would be similar to the role of a mouth mirror in dentistry. Such a tool is potentially useful for in-situ planetary geology applications for the close-up imaging of unexposed rock surfaces in cracks or those not in the direct line of sight. A conventional endoscope provides mostly a frontal view that is, a view along its longitudinal axis and, hence, along a straight line extending from an opening through which it is inserted. The MARVEL could be inserted through the same opening as that of the conventional endoscope, but could be adjusted to provide a view from almost any desired angle. The MARVEL camera image would be displayed, on the same monitor as that of the conventional endoscopic image, as an inset within the conventional endoscopic image. For example, while viewing a tumor from the front in the conventional endoscopic image, the surgeon could simultaneously view the tumor from the side or the rear in the MARVEL image, and could thereby gain additional visual cues that would aid in precise three-dimensional positioning of surgical tools to excise the tumor. Indeed, a side or rear view through the MARVEL could be essential in a case in which the object of surgical interest was not visible from the front. The conceptual design of the MARVEL exploits the surgeon s familiarity with endoscopic surgical tools. The MARVEL would include a miniature electronic camera and miniature radio transmitter mounted on the tip of a surgical tool derived from an endo-scissor (see figure). The inclusion of the radio transmitter would eliminate the need for wires, which could interfere with manipulation of this and other surgical tools. The handgrip of the tool would be connected to a linkage similar to that of an endo-scissor, but the linkage would be configured to enable adjustment of the camera angle instead of actuation of a scissor blade. It is envisioned that thicknesses of the tool shaft and the camera would be less than 4 mm, so that the camera-tipped tool could be swiftly inserted and withdrawn through a dime-size opening. Electronic cameras having dimensions of the order of millimeters are already commercially available, but their designs are not optimized for use in endoscopic brain surgery. The variety of potential endoscopic, thoracoscopic, and laparoscopic applications can be expected to increase as further development of electronic cameras yields further miniaturization and improvements in imaging performance.

  11. Robotics and systems technology for advanced endoscopic procedures: experiences in general surgery.

    PubMed

    Schurr, M O; Arezzo, A; Buess, G F

    1999-11-01

    The advent of endoscopic techniques changed surgery in many regards. This paper intends to describe an overview about technologies to facilitate endoscopic surgery. The systems described have been developed for the use in general surgery, but an easy application also in the field of cardiac surgery seems realistic. The introduction of system technology and robotic technology enables today to design a highly ergonomic solo-surgery platform. To relief the surgeon from fatigue we developed a new chair dedicated to the functional needs of endoscopic surgery. The foot pedals for high frequency, suction and irrigation are integrated into the basis of the chair. The chair is driven by electric motors controlled with an additional foot pedal joystick to achieve the desired position in the OR. A major enhancement for endoscopic technology is the introduction of robotic technology to design assisting devices for solo-surgery and manipulators for microsurgical instrumentation. A further step in the employment of robotic technology is the design of 'master-slave manipulators' to provide the surgeon with additional degrees of freedom of instrumentation. In 1996 a first prototype of an endoscopic manipulator system. named ARTEMIS, could be used in experimental applications. The system consists of a user station (master) and an instrument station (slave). The surgeon sits at a console which integrates endoscopic monitors, communication facilities and two master devices to control the two slave arms which are mounted to the operating table. Clinical use of the system, however, will require further development in the area of slave mechanics and the control system. Finally the implementation of telecommunication technology in combination with robotic instruments will open new frontiers, such as teleconsulting, teleassistance and telemanipulation.

  12. Streaming video-based 3D reconstruction method compatible with existing monoscopic and stereoscopic endoscopy systems

    NASA Astrophysics Data System (ADS)

    Bouma, Henri; van der Mark, Wannes; Eendebak, Pieter T.; Landsmeer, Sander H.; van Eekeren, Adam W. M.; ter Haar, Frank B.; Wieringa, F. Pieter; van Basten, Jean-Paul

    2012-06-01

    Compared to open surgery, minimal invasive surgery offers reduced trauma and faster recovery. However, lack of direct view limits space perception. Stereo-endoscopy improves depth perception, but is still restricted to the direct endoscopic field-of-view. We describe a novel technology that reconstructs 3D-panoramas from endoscopic video streams providing a much wider cumulative overview. The method is compatible with any endoscope. We demonstrate that it is possible to generate photorealistic 3D-environments from mono- and stereoscopic endoscopy. The resulting 3D-reconstructions can be directly applied in simulators and e-learning. Extended to real-time processing, the method looks promising for telesurgery or other remote vision-guided tasks.

  13. Optimizing the villi visualization by tethered capsule OCT endomicroscopy for comprehensive imaging of human duodenum (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Dong, Jing; Gora, Michalina J.; Beaulieu-Ouellet, Emilie; Queneherve, Lucille H.; Grant, Catriona N.; Rosenberg, Mireille; Nishioka, Norman S.; Fasano, Alessio; Tearney, Guillermo J.

    2017-02-01

    Celiac disease (CD) affects around 1% of the global population and can cause serious long-term symptoms including malnutrition, fatigue, and diarrhea, amongst others. Despite this, it is often left undiagnosed. Currently, a tissue diagnosis of CD is made by random endoscopic biopsy of the duodenum to confirm the existence of microscopic morphologic alterations in the intestinal mucosa. However, duodenal endoscopic biopsy is problematic because the morphological changes can be focal and endoscopic biopsy is plagued by sampling error. Additionally, tissue artifacts can also an issue because cuts in the transverse plane can make duodenal villi appear artifactually shortened and can bias the assessment of intraepithelial inflammation. Moreover, endoscopic biopsy is costly and poorly tolerated as the patient needs to be sedated to perform the procedure. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. TCE involves swallowing an optomechanically-engineered pill that generates 3D images of the GI tract as it traverses the lumen of the organ via peristalsis, assisted by gravity. In several patients we have demonstrated TCE imaging of duodenal villi, however the current TCE device design is not optimal for CD diagnosis as the villi compress when in contact with the smooth capsule's wall. In this work, we present methods for structuring the outer surface of the capsule to improve the visualization of the villi height and crypt depth. Preliminary results in humans suggest that new TCE capsule enables better visualization of villous architecture, making it possibly to comprehensively scan the entire duodenum to obtain a more accurate tissue diagnosis of CD.

  14. Endoscopic ultrasound for the characterization and staging of rectal cancer. Current state of the method. Technological advances and perspectives.

    PubMed

    Gersak, Mariana M; Badea, Radu; Graur, Florin; Hajja, Nadim Al; Furcea, Luminita; Dudea, Sorin M

    2015-06-01

    Endoscopic ultrasound is the most accurate type of examination for the assessment of rectal tumors. Over the years, the method has advanced from gray-scale examination to intravenous contrast media administration and to different types of elastography. The multimodal approach of tumors (transrectal, transvaginal) is adapted to each case. 3D ultrasound is useful for spatial representation and precise measurement of tumor formations, using CT/MR image reconstruction; color elastography is useful for tumor characterization and staging; endoscopic ultrasound using intravenous contrast agents can help study the amount of contrast agent targeted at the level of the tumor formations and contrast wash-in/wash-out time, based on the curves displayed on the device. The transvaginal approach often allows better visualization of the tumor than the transrectal approach. Performing the procedure with the rectal ampulla distended with contrast agent may be seen as an optimization of the examination methodology. All these aspects are additional methods for gray-scale endoscopic ultrasound, capable of increasing diagnostic accuracy. This paper aims at reviewing the progress of transrectal and transvaginal ultrasound, generically called endoscopic ultrasound, for rectal tumor diagnosis and staging, with emphasis on the current state of the method and its development trends.

  15. Robotics in endoscopy.

    PubMed

    Klibansky, David; Rothstein, Richard I

    2012-09-01

    The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.

  16. Current status of device-assisted enteroscopy: Technical matters, indication, limits and complications

    PubMed Central

    Riccioni, Maria Elena; Urgesi, Riccardo; Cianci, Rossella; Bizzotto, Alessandra; Galasso, Domenico; Costamagna, Guido

    2012-01-01

    Enteroscopy, defined as direct visualization of the small bowel with the use of a fiberoptic or capsule endoscopy, has progressed considerably over the past several years. The need for endoscopic access to improve diagnosis and treatment of small bowel disease has led to the development of novel technologies one of which is non-invasive, the video capsule, and a type of invasive technique, the device-assisted enteroscopy. In particular, the device-assisted enteroscopy consists then of three different types of instruments all able to allow, in skilled hands, to display partially or throughout its extension (if necessary) the small intestine. Newer devices, double balloon, single balloon and spiral endoscopy, are just entering clinical use. The aim of this article is to review recent advances in small bowel enteroscopy, focusing on indications, modifications to improve imaging and techniques, pitfalls, and clinical applications of the new instruments. With new technologies, the trials and tribulations of learning new endoscopic skills and determining their role in the diagnosis and treatment of small bowel disease come. Identification of small bowel lesions has dramatically improved. Studies are underway to determine the best strategy to apply new enteroscopy technologies for the diagnosis and management of small bowel disease, particularly obscure bleeding. Vascular malformations such as angiectasis and small bowel neoplasms as adenocarcinoma or gastrointestinal stromal tumors. Complete enteroscopy of the small bowel is now possible. However, because of the length of the small bowel, endoscopic examination and therapeutic maneuvers require significant skill, radiological assistance, the use of deep sedation with the assistance of the anesthetist. Prospective randomized studies are needed to guide diagnostic testing and therapy with these new endoscopic techniques. PMID:23189216

  17. A high definition Mueller polarimetric endoscope for tissue characterisation

    NASA Astrophysics Data System (ADS)

    Qi, Ji; Elson, Daniel S.

    2016-05-01

    The contrast mechanism of medical endoscopy is mainly based on metrics of optical intensity and wavelength. As another fundamental property of light, polarization can not only reveal tissue scattering and absorption information from a different perspective, but can also provide insight into directional tissue birefringence properties to monitor pathological changes in collagen and elastin. Here we demonstrate a low cost wide field high definition Mueller polarimetric endoscope with minimal alterations to a rigid endoscope. We show that this novel endoscopic imaging modality is able to provide a number of image contrast mechanisms besides traditional unpolarized radiation intensity, including linear depolarization, circular depolarization, cross-polarization, directional birefringence and dichroism. This enhances tissue features of interest, and additionally reveals tissue micro-structure and composition, which is of central importance for tissue diagnosis and image guidance for surgery. The potential applications of the Mueller polarimetric endoscope include wide field early epithelial cancer diagnosis, surgical margin detection and energy-based tissue fusion monitoring, and could further benefit a wide range of endoscopic investigations through intra-operative guidance.

  18. Endoscopic ultrasound

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/007646.htm Endoscopic ultrasound To use the sharing features on this page, please enable JavaScript. Endoscopic ultrasound is a type of imaging test. It is ...

  19. Design of an autofocus capsule endoscope system and the corresponding 3D reconstruction algorithm.

    PubMed

    Zhang, Wei; Jin, Yi-Tao; Guo, Xin; Su, Jin-Hui; You, Su-Ping

    2016-10-01

    A traditional capsule endoscope can only take 2D images, and most of the images are not clear enough to be used for diagnosing. A 3D capsule endoscope can help doctors make a quicker and more accurate diagnosis. However, blurred images negatively affect reconstruction accuracy. A compact, autofocus capsule endoscope system is designed in this study. Using a liquid lens, the system can be electronically controlled to autofocus, and without any moving elements. The depth of field of the system is in the 3-100 mm range and its field of view is about 110°. The images captured by this optical system are much clearer than those taken by a traditional capsule endoscope. A 3D reconstruction algorithm is presented to adapt to the zooming function of our proposed system. Simulations and experiments have shown that more feature points can be correctly matched and a higher reconstruction accuracy can be achieved by this strategy.

  20. Full optical model of micro-endoscope with optical coherence microscopy, multiphoton microscopy and visible capabilities

    NASA Astrophysics Data System (ADS)

    Vega, David; Kiekens, Kelli C.; Syson, Nikolas C.; Romano, Gabriella; Baker, Tressa; Barton, Jennifer K.

    2018-02-01

    While Optical Coherence Microscopy (OCM), Multiphoton Microscopy (MPM), and narrowband imaging are powerful imaging techniques that can be used to detect cancer, each imaging technique has limitations when used by itself. Combining them into an endoscope to work in synergy can help achieve high sensitivity and specificity for diagnosis at the point of care. Such complex endoscopes have an elevated risk of failure, and performing proper modelling ensures functionality and minimizes risk. We present full 2D and 3D models of a multimodality optical micro-endoscope to provide real-time detection of carcinomas, called a salpingoscope. The models evaluate the endoscope illumination and light collection capabilities of various modalities. The design features two optical paths with different numerical apertures (NA) through a single lens system with a scanning optical fiber. The dual path is achieved using dichroic coatings embedded in a triplet. A high NA optical path is designed to perform OCM and MPM while a low NA optical path is designed for the visible spectrum to navigate the endoscope to areas of interest and narrowband imaging. Different tests such as the reflectance profile of homogeneous epithelial tissue were performed to adjust the models properly. Light collection models for the different modalities were created and tested for efficiency. While it is challenging to evaluate the efficiency of multimodality endoscopes, the models ensure that the system is design for the expected light collection levels to provide detectable signal to work for the intended imaging.

  1. Development and Preliminary Application of High-Resolution Endoscopic Piv for Quantification of Flow Structure Within a Pore Space

    NASA Astrophysics Data System (ADS)

    Blois, G.; Sambrook Smith, G.; Best, J.; Hardy, R.; Lead, J.

    2008-12-01

    Most natural rivers have beds of loose, cohesionless sediment that form a porous bed, thus permitting significant interactions between the free flow above the bed and that within the pore spaces. Many unresolved problems in channel engineering and ecohydraulics are related to an incomplete understanding of this interstitial flow. For example, the mechanisms of pollutant transport and prediction of river bed morphodynamics may be strongly influenced by flow occurring within the pore spaces. While this lack of understanding has been widely acknowledged, the direct experimental investigation of flow within the pore spaces has been restricted by the practical difficulties in collecting such data. This has also created drawbacks in the numerical modeling of pore flow as there remains a dearth of robust experimental data with which to validate such models. In order to help address these issues, we present details of a new endoscopic PIV system designed to tackle some of the challenges highlighted above. The work presented in this paper is also being used to validate a numerical model that is being developed as part of this project. A fully endoscopic PIV system has been developed to collect velocity and turbulence data for flow within the pore space of a gravel bed. The system comprises a pulsed Nd:YAG laser that provides high intensity illumination for single exposure pairs of images on a high-resolution digital camera. The use of rigid endoscopes for both the laser light source and camera allows measurement of quasi-instantaneous flow fields by high-resolution PIV images (2352*1728 pixels). In the first instance, the endoscopic PIV system has been used to study flow within an artificial pore space model constructed from 38 and 51 mm diameter spheres, used to represent a simplified version of a natural gravel-bed river. Across-correlation processing approach has been applied to the PIV images and the processing parameters have been optimized for the experimental conditions. A series of instantaneous two-dimensional flow fields in a simple pore space has been reconstructed permitting quantification of the mean flow. A not symmetric flow structure has been highlighted showing the strong dependence of flow on the bed geometry and presence of the free surface. Preliminary results will be discussed here in order to highlight the critical aspects of the technique. Illumination from the laser endoscope must be optimized in terms of angle of divergence, uniformity and stability, with any source of irregular illumination causing strong reflections from the surface of the spheres resulting in saturation of huge image areas. The preliminary results obtained demonstrate the utility of the fully endoscopic PIV technique for investigation of flow structure in pore spaces. Further developments of the technique will include improving light uniformity, removing reflections from images and increasing the illuminated portion of the pore space area.

  2. Evolution of Minimally Invasive Approaches to the Sella and Parasellar Region

    PubMed Central

    Louis, Robert G.; Eisenberg, Amy; Barkhoudarian, Garni; Griffiths, Chester; Kelly, Daniel F.

    2014-01-01

    Introduction Given advancements in endoscopic image quality, instrumentation, surgical navigation, skull base closure techniques, and anatomical understanding, the endonasal endoscopic approach has rapidly evolved into a widely utilized technique for removal of sellar and parasellar tumors. Although pituitary adenomas and Rathke cleft cysts constitute the majority of lesions removed via this route, craniopharyngiomas, clival chordomas, parasellar meningiomas, and other lesions are increasingly removed using this approach. Paralleling the evolution of the endonasal route to the parasellar region, the supraorbital eyebrow craniotomy has also been increasingly used as an alternative minimally invasive approach to reach this skull base region. Similar to the endonasal route, the supraorbital route has been greatly facilitated by advances in endoscopy, along with development of more refined, low-profile instrumentation and surgical navigation technology. Objectives This review, encompassing both transcranial and transsphenoidal routes, will recount the high points and advances that have made minimally invasive approaches to the sellar region possible, the evolution of these approaches, and their relative indications and technical nuances. Data Synthesis The literature is reviewed regarding the evolution of surgical approaches to the sellar region beginning with the earliest attempts and emphasizing technological advances, which have allowed the evolution of the modern technique. The surgical techniques for both endoscopic transsphenoidal and supraorbital approaches are described in detail. The relative indications for each approach are highlighted using case illustrations. Conclusions Although tremendous advances have been made in transitioning toward minimally invasive transcranial and transsphenoidal approaches to the sella, further work remains to be done. Together, the endonasal endoscopic and the supraorbital endoscope-assisted approaches are complementary minimally invasive routes to the parasellar region. PMID:25992138

  3. Endoscopic near-infrared dental imaging with indocyanine green: a pilot study.

    PubMed

    Li, Zhongqiang; Yao, Shaomian; Xu, Jian; Wu, Ye; Li, Chunhong; He, Ziying

    2018-06-01

    Current dental diagnosis, especially tooth abnormalities, relies largely on X-ray-based imaging, a technique that requires specialized skills and suffers from ionizing radiation. Here, we present a pilot study in rats of an efficient, ionizing-radiation-free and easy-to-use alternative for dental imaging. Postnatal rats at different ages were injected with indocyanine green and molars were imaged by a laboratory-designed endoscopic near-infrared (NIR) dental imaging system. The results indicate that the endoscopic NIR dental imaging can be used to observe the morphology of postnatal rat molars, especially at early postnatal stages when morphology of the molar is indistinguishable under visible conditions. A small abnormal cusp was observed and distinguished from the normal cusps by the NIR dental imaging system. Dental structures, such as unerupted molars, can be imaged as soon as 10 min after the injection of indocyanine green; imaging after 24 h shows improved imaging contrast. Overall, the endoscopic NIR fluorescence dental imaging system described here may be useful in dental research; this technique may serve as a safe, real-time imaging tool for dental diagnosis and treatment beyond experimental systems in the future. © 2018 New York Academy of Sciences.

  4. The UTCOMS: a wireless video capsule nanoendoscope

    NASA Astrophysics Data System (ADS)

    Lee, Mike M.; Lee, Eun-Mi; Cho, Byung Lok; Eshraghian, Kamran; Kim, Yun-Hyun

    2006-02-01

    This research shows a 1mW Low Power and real-time imaging Tx/Rx communication system via RF-delay smart Antenna using up to 10GHz UWB(Ultra WideBand) as a concept of Wireless Medical Telemetry Service (WMTS). This UTCOMS (COMmunication System for Nano-scale USLI designed Endoscope using UWB technology) results in less body loss(about 6~13dB) at high frequency, disposable and ingestible compact size of 5×10 mm2 and multifunction, bidirectional communications, independent subsystem control multichannel, and high sensitivity smart receiving antenna of three-dimensional image captured still and moving images.

  5. Visual servoing in medical robotics: a survey. Part I: endoscopic and direct vision imaging - techniques and applications.

    PubMed

    Azizian, Mahdi; Khoshnam, Mahta; Najmaei, Nima; Patel, Rajni V

    2014-09-01

    Intra-operative imaging is widely used to provide visual feedback to a clinician when he/she performs a procedure. In visual servoing, surgical instruments and parts of tissue/body are tracked by processing the acquired images. This information is then used within a control loop to manoeuvre a robotic manipulator during a procedure. A comprehensive search of electronic databases was completed for the period 2000-2013 to provide a survey of the visual servoing applications in medical robotics. The focus is on medical applications where image-based tracking is used for closed-loop control of a robotic system. Detailed classification and comparative study of various contributions in visual servoing using endoscopic or direct visual images are presented and summarized in tables and diagrams. The main challenges in using visual servoing for medical robotic applications are identified and potential future directions are suggested. 'Supervised automation of medical robotics' is found to be a major trend in this field. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Color reproduction and processing algorithm based on real-time mapping for endoscopic images.

    PubMed

    Khan, Tareq H; Mohammed, Shahed K; Imtiaz, Mohammad S; Wahid, Khan A

    2016-01-01

    In this paper, we present a real-time preprocessing algorithm for image enhancement for endoscopic images. A novel dictionary based color mapping algorithm is used for reproducing the color information from a theme image. The theme image is selected from a nearby anatomical location. A database of color endoscopy image for different location is prepared for this purpose. The color map is dynamic as its contents change with the change of the theme image. This method is used on low contrast grayscale white light images and raw narrow band images to highlight the vascular and mucosa structures and to colorize the images. It can also be applied to enhance the tone of color images. The statistic visual representation and universal image quality measures show that the proposed method can highlight the mucosa structure compared to other methods. The color similarity has been verified using Delta E color difference, structure similarity index, mean structure similarity index and structure and hue similarity. The color enhancement was measured using color enhancement factor that shows considerable improvements. The proposed algorithm has low and linear time complexity, which results in higher execution speed than other related works.

  7. Optical Coherence Microscopy

    NASA Astrophysics Data System (ADS)

    Aguirre, Aaron D.; Zhou, Chao; Lee, Hsiang-Chieh; Ahsen, Osman O.; Fujimoto, James G.

    Cellular imaging of human tissues remains an important advance for many clinical applications of optical coherence tomography (OCT). Imaging cells with traditional OCT systems has not been possible due to the limited transverse resolution of such techniques. Optical coherence microscopy (OCM) refers to OCT methods that achieve high transverse resolution to visualize cells and subcellular features. This chapter provides a comprehensive discussion of the rationale for cellular imaging in human tissues as well as a review of the key technological advances required to achieve it. Time domain and Fourier domain OCM approaches are described with an emphasis on state of the art system designs, including miniaturized endoscopic imaging probes. Clinical applications are discussed and multiple examples of cellular imaging in human tissues are provided.

  8. Computer-Aided Diagnosis Based on Convolutional Neural Network System for Colorectal Polyp Classification: Preliminary Experience.

    PubMed

    Komeda, Yoriaki; Handa, Hisashi; Watanabe, Tomohiro; Nomura, Takanobu; Kitahashi, Misaki; Sakurai, Toshiharu; Okamoto, Ayana; Minami, Tomohiro; Kono, Masashi; Arizumi, Tadaaki; Takenaka, Mamoru; Hagiwara, Satoru; Matsui, Shigenaga; Nishida, Naoshi; Kashida, Hiroshi; Kudo, Masatoshi

    2017-01-01

    Computer-aided diagnosis (CAD) is becoming a next-generation tool for the diagnosis of human disease. CAD for colon polyps has been suggested as a particularly useful tool for trainee colonoscopists, as the use of a CAD system avoids the complications associated with endoscopic resections. In addition to conventional CAD, a convolutional neural network (CNN) system utilizing artificial intelligence (AI) has been developing rapidly over the past 5 years. We attempted to generate a unique CNN-CAD system with an AI function that studied endoscopic images extracted from movies obtained with colonoscopes used in routine examinations. Here, we report our preliminary results of this novel CNN-CAD system for the diagnosis of colon polyps. A total of 1,200 images from cases of colonoscopy performed between January 2010 and December 2016 at Kindai University Hospital were used. These images were extracted from the video of actual endoscopic examinations. Additional video images from 10 cases of unlearned processes were retrospectively assessed in a pilot study. They were simply diagnosed as either an adenomatous or nonadenomatous polyp. The number of images used by AI to learn to distinguish adenomatous from nonadenomatous was 1,200:600. These images were extracted from the videos of actual endoscopic examinations. The size of each image was adjusted to 256 × 256 pixels. A 10-hold cross-validation was carried out. The accuracy of the 10-hold cross-validation is 0.751, where the accuracy is the ratio of the number of correct answers over the number of all the answers produced by the CNN. The decisions by the CNN were correct in 7 of 10 cases. A CNN-CAD system using routine colonoscopy might be useful for the rapid diagnosis of colorectal polyp classification. Further prospective studies in an in vivo setting are required to confirm the effectiveness of a CNN-CAD system in routine colonoscopy. © 2017 S. Karger AG, Basel.

  9. Intra-operative registration for image enhanced endoscopic sinus surgery using photo-consistency.

    PubMed

    Chen, Min Si; Gonzalez, Gerardo; Lapeer, Rudy

    2007-01-01

    The purpose of this paper is to present an intensity based algorithm for aligning 2D endoscopic images with virtual images generated from pre-operative 3D data. The proposed algorithm uses photo-consistency as the measurement of similarity between images, provided the illumination is independent from the viewing direction.

  10. Robust feature tracking for endoscopic pose estimation and structure recovery

    NASA Astrophysics Data System (ADS)

    Speidel, S.; Krappe, S.; Röhl, S.; Bodenstedt, S.; Müller-Stich, B.; Dillmann, R.

    2013-03-01

    Minimally invasive surgery is a highly complex medical discipline with several difficulties for the surgeon. To alleviate these difficulties, augmented reality can be used for intraoperative assistance. For visualization, the endoscope pose must be known which can be acquired with a SLAM (Simultaneous Localization and Mapping) approach using the endoscopic images. In this paper we focus on feature tracking for SLAM in minimally invasive surgery. Robust feature tracking and minimization of false correspondences is crucial for localizing the endoscope. As sensory input we use a stereo endoscope and evaluate different feature types in a developed SLAM framework. The accuracy of the endoscope pose estimation is validated with synthetic and ex vivo data. Furthermore we test the approach with in vivo image sequences from da Vinci interventions.

  11. Hyperspectral imaging fluorescence excitation scanning for colon cancer detection

    PubMed Central

    Leavesley, Silas J.; Walters, Mikayla; Lopez, Carmen; Baker, Thomas; Favreau, Peter F.; Rich, Thomas C.; Rider, Paul F.; Boudreaux, Carole W.

    2016-01-01

    Abstract. Optical spectroscopy and hyperspectral imaging have shown the potential to discriminate between cancerous and noncancerous tissue with high sensitivity and specificity. However, to date, these techniques have not been effectively translated to real-time endoscope platforms. Hyperspectral imaging of the fluorescence excitation spectrum represents new technology that may be well suited for endoscopic implementation. However, the feasibility of detecting differences between normal and cancerous mucosa using fluorescence excitation-scanning hyperspectral imaging has not been evaluated. The goal of this study was to evaluate the initial feasibility of using fluorescence excitation-scanning hyperspectral imaging for measuring changes in fluorescence excitation spectrum concurrent with colonic adenocarcinoma using a small pre-pilot-scale sample size. Ex vivo analysis was performed using resected pairs of colorectal adenocarcinoma and normal mucosa. Adenocarcinoma was confirmed by histologic evaluation of hematoxylin and eosin (H&E) permanent sections. Specimens were imaged using a custom hyperspectral imaging fluorescence excitation-scanning microscope system. Results demonstrated consistent spectral differences between normal and cancerous tissues over the fluorescence excitation range of 390 to 450 nm that could be the basis for wavelength-dependent detection of colorectal cancers. Hence, excitation-scanning hyperspectral imaging may offer an alternative approach for discriminating adenocarcinoma from surrounding normal colonic mucosa, but further studies will be required to evaluate the accuracy of this approach using a larger patient cohort. PMID:27792808

  12. Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology.

    PubMed

    Tsai, Tsung-Han; Potsaid, Benjamin; Tao, Yuankai K; Jayaraman, Vijaysekhar; Jiang, James; Heim, Peter J S; Kraus, Martin F; Zhou, Chao; Hornegger, Joachim; Mashimo, Hiroshi; Cable, Alex E; Fujimoto, James G

    2013-07-01

    We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, which is not sensitive to the bending of the catheter. The side-viewing probe can be pulled back to acquire a three-dimensional (3D) data set covering a large area on the specimen. The VCSEL provides a high axial scan rate to support dense sampling under high frame rate operation. Using a high speed data acquisition system, in vivo 3D-OCT imaging in the rabbit GI tract and ex vivo imaging of a human colon specimen with 8 μm axial resolution, 8 μm lateral resolution and 1.2 mm depth range in tissue at a frame rate of 400 fps was demonstrated.

  13. Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology

    PubMed Central

    Tsai, Tsung-Han; Potsaid, Benjamin; Tao, Yuankai K.; Jayaraman, Vijaysekhar; Jiang, James; Heim, Peter J. S.; Kraus, Martin F.; Zhou, Chao; Hornegger, Joachim; Mashimo, Hiroshi; Cable, Alex E.; Fujimoto, James G.

    2013-01-01

    We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, which is not sensitive to the bending of the catheter. The side-viewing probe can be pulled back to acquire a three-dimensional (3D) data set covering a large area on the specimen. The VCSEL provides a high axial scan rate to support dense sampling under high frame rate operation. Using a high speed data acquisition system, in vivo 3D-OCT imaging in the rabbit GI tract and ex vivo imaging of a human colon specimen with 8 μm axial resolution, 8 μm lateral resolution and 1.2 mm depth range in tissue at a frame rate of 400 fps was demonstrated. PMID:23847737

  14. Using typical endoscopic features to diagnose esophageal squamous papilloma.

    PubMed

    Wong, Ming-Wun; Bair, Ming-Joug; Shih, Shou-Chuan; Chu, Cheng-Hsin; Wang, Horng-Yuan; Wang, Tsang-En; Chang, Chen-Wang; Chen, Ming-Jen

    2016-02-21

    To better understand some of the superficial tiny lesions that are recognized as squamous papilloma of the esophagus (SPE) and receive a different pathological diagnosis. All consecutive patients with esophageal polypoid lesions detected by routine endoscopy at our Endoscopy Centre between October 2009 and June 2014 were retrospectively analysed. We enrolled patients with SPE or other superficial lesions to investigate four key endoscopic appearances (whitish color, exophytic growth, wart-like shape, and surface vessels) and used narrow band imaging (NBI) to distinguish their differences. These series endoscopic images of each patient were retrospectively reviewed by three experienced endoscopists with no prior access to the images. All lesion specimens obtained by forceps biopsy were fixed in formalin and processed for pathological examination. The following data were collected from patient medical records: gender, age, indications for esophagogastroduodenoscopy, and endoscopic characteristics including lesion location, number, color, size, surface morphology, surrounding mucosa, and surface vessels under NBI. Clinicopathological features were also compared. During the study period, 41 esophageal polypoid lesions from 5698 endoscopic examinations were identified retrospectively. These included 24 patients with pathologically confirmed SPE, 11 patients with squamous hyperplasia, three patients with glycogenic acanthosis, two patients with ectopic sebaceous glands, and one patient with a xanthoma. In the χ (2) test, exophytic growth (P = 0.003), a wart-like shape (P < 0.001), and crossing surface vessels under NBI (P = 0.001) were more frequently observed in SPE than in other lesion types. By contrast, there was no significant difference regarding the appearance of a whitish color between SPE and other lesion types (P = 0.872). The most sensitive characteristic was wart-like projections (81.3%) and the most specific was exophytic growth (87.5%). Promising positive predictive values of 84.2%, 80.8%, and 82.6% were noted for exophytic growth, wart-like projections, and surface vessel crossing on NBI, respectively. The use of three key typical endoscopic appearances--exophytic growth, a wart-like shape, and vessel crossing on the lesion surface under NBI--has a promising positive predictive value of 88.2%. This diagnostic triad is useful for the endoscopic diagnosis of SPE.

  15. Using typical endoscopic features to diagnose esophageal squamous papilloma

    PubMed Central

    Wong, Ming-Wun; Bair, Ming-Joug; Shih, Shou-Chuan; Chu, Cheng-Hsin; Wang, Horng-Yuan; Wang, Tsang-En; Chang, Chen-Wang; Chen, Ming-Jen

    2016-01-01

    AIM: To better understand some of the superficial tiny lesions that are recognized as squamous papilloma of the esophagus (SPE) and receive a different pathological diagnosis. METHODS: All consecutive patients with esophageal polypoid lesions detected by routine endoscopy at our Endoscopy Centre between October 2009 and June 2014 were retrospectively analysed. We enrolled patients with SPE or other superficial lesions to investigate four key endoscopic appearances (whitish color, exophytic growth, wart-like shape, and surface vessels) and used narrow band imaging (NBI) to distinguish their differences. These series endoscopic images of each patient were retrospectively reviewed by three experienced endoscopists with no prior access to the images. All lesion specimens obtained by forceps biopsy were fixed in formalin and processed for pathological examination. The following data were collected from patient medical records: gender, age, indications for esophagogastroduodenoscopy, and endoscopic characteristics including lesion location, number, color, size, surface morphology, surrounding mucosa, and surface vessels under NBI. Clinicopathological features were also compared. RESULTS: During the study period, 41 esophageal polypoid lesions from 5698 endoscopic examinations were identified retrospectively. These included 24 patients with pathologically confirmed SPE, 11 patients with squamous hyperplasia, three patients with glycogenic acanthosis, two patients with ectopic sebaceous glands, and one patient with a xanthoma. In the χ2 test, exophytic growth (P = 0.003), a wart-like shape (P < 0.001), and crossing surface vessels under NBI (P = 0.001) were more frequently observed in SPE than in other lesion types. By contrast, there was no significant difference regarding the appearance of a whitish color between SPE and other lesion types (P = 0.872). The most sensitive characteristic was wart-like projections (81.3%) and the most specific was exophytic growth (87.5%). Promising positive predictive values of 84.2%, 80.8%, and 82.6% were noted for exophytic growth, wart-like projections, and surface vessel crossing on NBI, respectively. CONCLUSION: The use of three key typical endoscopic appearances - exophytic growth, a wart-like shape, and vessel crossing on the lesion surface under NBI - has a promising positive predictive value of 88.2%. This diagnostic triad is useful for the endoscopic diagnosis of SPE. PMID:26900297

  16. Image-guided biopsy in the esophagus through comprehensive optical frequency domain imaging and laser marking: a study in living swine.

    PubMed

    Suter, Melissa J; Jillella, Priyanka A; Vakoc, Benjamin J; Halpern, Elkan F; Mino-Kenudson, Mari; Lauwers, Gregory Y; Bouma, Brett E; Nishioka, Norman S; Tearney, Guillermo J

    2010-02-01

    Random biopsy esophageal surveillance can be subject to sampling errors, resulting in diagnostic uncertainty. Optical frequency domain imaging (OFDI) is a high-speed, 3-dimensional endoscopic microscopy technique. When deployed through a balloon-centering catheter, OFDI can automatically image the entire distal esophagus (6.0 cm length) in approximately 2 minutes. To test a new platform for guided biopsy that allows the operator to select target regions of interest on an OFDI dataset, and then use a laser to mark the esophagus at corresponding locations. The specific goals include determining the optimal laser parameters, testing the accuracy of the laser marking process, evaluating the endoscopic visibility of the laser marks, and assessing the amount of mucosal damage produced by the laser. Experimental study conducted in 5 swine in vivo. Massachusetts General Hospital. Success rate, including endoscopic visibility of laser marks and accuracy of the laser marking process for selected target sites, and extent of the thermal damage caused by the laser marks. All of the laser-induced marks were visible by endoscopy. Target locations were correctly marked with a success rate of 97.07% (95% confidence interval, 89.8%-99.7%). Thermal damage was limited to the superficial layers of the mucosa and was observed to partially heal within 2 days. An animal study with artificially placed targets to simulate pathology. The study demonstrates that laser marking of esophageal sites identified in comprehensive OFDI datasets is feasible and can be performed with sufficient accuracy, precision, and visibility to guide biopsy in vivo.

  17. Linked color imaging application for improving the endoscopic diagnosis accuracy: a pilot study.

    PubMed

    Sun, Xiaotian; Dong, Tenghui; Bi, Yiliang; Min, Min; Shen, Wei; Xu, Yang; Liu, Yan

    2016-09-19

    Endoscopy has been widely used in diagnosing gastrointestinal mucosal lesions. However, there are still lack of objective endoscopic criteria. Linked color imaging (LCI) is newly developed endoscopic technique which enhances color contrast. Thus, we investigated the clinical application of LCI and further analyzed pixel brightness for RGB color model. All the lesions were observed by white light endoscopy (WLE), LCI and blue laser imaging (BLI). Matlab software was used to calculate pixel brightness for red (R), green (G) and blue color (B). Of the endoscopic images for lesions, LCI had significantly higher R compared with BLI but higher G compared with WLE (all P < 0.05). R/(G + B) was significantly different among 3 techniques and qualified as a composite LCI marker. Our correlation analysis of endoscopic diagnosis with pathology revealed that LCI was quite consistent with pathological diagnosis (P = 0.000) and the color could predict certain kinds of lesions. ROC curve demonstrated at the cutoff of R/(G+B) = 0.646, the area under curve was 0.646, and the sensitivity and specificity was 0.514 and 0.773. Taken together, LCI could improve efficiency and accuracy of diagnosing gastrointestinal mucosal lesions and benefit target biopsy. R/(G + B) based on pixel brightness may be introduced as a objective criterion for evaluating endoscopic images.

  18. Improving patient and user safety during endoscopic investigation of the pancreatic and biliary ducts

    NASA Astrophysics Data System (ADS)

    Chandler, John E.; Melville, C. David; Lee, Cameron M.; Saunders, Michael D.; Burkhardt, Matthew R.; Seibel, Eric J.

    2011-03-01

    Endoscopic investigation of the main pancreatic duct and biliary ducts is called endoscopic retrograde cholangiopancreatography (ERCP), and carries a risk of pancreatitis for the patient. During ERCP, a metal guidewire is inserted into the pancreatobiliary duct from a side-viewing large endoscope within the duodenum. To verify correct placement of the ERCP guidewire, an injection of radiopaque dye is required for fluoroscopic imaging, which exposes the patient and clinical team to x-ray radiation. A safer and more effective means to access the pancreatobiliary system can use direct optical imaging, although the endoscope diameter and stiffness will be significantly larger than a guidewire's. To quantify this invasiveness before human testing, a synthetic force-sensing pancreas was fabricated and attached to an ERCP training model. The invasiveness of a new, 1.7-mm diameter, steerable scanning fiber endoscope (SFE) was compared to the standard ERCP guidewire of 0.89-mm (0.035") diameter that is not steerable. Although twice as large and significantly stiffer than the ERCP guidewire, the SFE generated lower or significantly less average force during insertion at all 4 sensor locations (P<0.05) within the main pancreatic duct. Therefore, the addition of steering and forward visualization at the tip of the endoscope reduced the invasiveness of the in vitro ERCP procedure. Since fluoroscopy is not required, risks associated with dye injection and x-ray exposure can be eliminated when using direct optical visualization. Finally, the SFE provides wide-field high resolution imaging for image-guided interventions, laser-based fluorescence biomarker imaging, and spot spectral analysis for future optical biopsy.

  19. Monte Carlo model of light transport in multi-layered tubular organs

    NASA Astrophysics Data System (ADS)

    Zhang, Yunyao; Zhu, Jingping; Zhang, Ning

    2017-02-01

    We present a Monte Carlo static light migration model (Endo-MCML) to simulate endoscopic optical spectroscopy for tubular organs such as esophagus and colon. The model employs multi-layered hollow cylinder which emitting and receiving light both from the inner boundary to meet the conditions of endoscopy. Inhomogeneous sphere can be added in tissue layers to model cancer or other abnormal changes. The 3D light distribution and exit angle would be recorded as results. The accuracy of the model has been verified by Multi-layered Monte Carlo(MCML) method and NIRFAST. This model can be used for the forward modeling of light transport during endoscopically diffuse optical spectroscopy, light scattering spectroscopy, reflectance spectroscopy and other static optical detection or imaging technologies.

  20. Three-Dimensional Photoacoustic Endoscopic Imaging of the Rabbit Esophagus

    PubMed Central

    Yao, Junjie; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2015-01-01

    We report photoacoustic and ultrasonic endoscopic images of two intact rabbit esophagi. To investigate the esophageal lumen structure and microvasculature, we performed in vivo and ex vivo imaging studies using a 3.8-mm diameter photoacoustic endoscope and correlated the images with histology. Several interesting anatomic structures were newly found in both the in vivo and ex vivo images, which demonstrates the potential clinical utility of this endoscopic imaging modality. In the ex vivo imaging experiment, we acquired high-resolution motion-artifact-free three-dimensional photoacoustic images of the vasculatures distributed in the walls of the esophagi and extending to the neighboring mediastinal regions. Blood vessels with apparent diameters as small as 190 μm were resolved. Moreover, by taking advantage of the dual-mode high-resolution photoacoustic and ultrasound endoscopy, we could better identify and characterize the anatomic structures of the esophageal lumen, such as the mucosal and submucosal layers in the esophageal wall, and an esophageal branch of the thoracic aorta. In this paper, we present the first photoacoustic images showing the vasculature of a vertebrate esophagus and discuss the potential clinical applications and future development of photoacoustic endoscopy. PMID:25874640

  1. Three-dimensional photoacoustic endoscopic imaging of the rabbit esophagus.

    PubMed

    Yang, Joon Mo; Favazza, Christopher; Yao, Junjie; Chen, Ruimin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2015-01-01

    We report photoacoustic and ultrasonic endoscopic images of two intact rabbit esophagi. To investigate the esophageal lumen structure and microvasculature, we performed in vivo and ex vivo imaging studies using a 3.8-mm diameter photoacoustic endoscope and correlated the images with histology. Several interesting anatomic structures were newly found in both the in vivo and ex vivo images, which demonstrates the potential clinical utility of this endoscopic imaging modality. In the ex vivo imaging experiment, we acquired high-resolution motion-artifact-free three-dimensional photoacoustic images of the vasculatures distributed in the walls of the esophagi and extending to the neighboring mediastinal regions. Blood vessels with apparent diameters as small as 190 μm were resolved. Moreover, by taking advantage of the dual-mode high-resolution photoacoustic and ultrasound endoscopy, we could better identify and characterize the anatomic structures of the esophageal lumen, such as the mucosal and submucosal layers in the esophageal wall, and an esophageal branch of the thoracic aorta. In this paper, we present the first photoacoustic images showing the vasculature of a vertebrate esophagus and discuss the potential clinical applications and future development of photoacoustic endoscopy.

  2. Reevaluation of JPEG image compression to digitalized gastrointestinal endoscopic color images: a pilot study

    NASA Astrophysics Data System (ADS)

    Kim, Christopher Y.

    1999-05-01

    Endoscopic images p lay an important role in describing many gastrointestinal (GI) disorders. The field of radiology has been on the leading edge of creating, archiving and transmitting digital images. With the advent of digital videoendoscopy, endoscopists now have the ability to generate images for storage and transmission. X-rays can be compressed 30-40X without appreciable decline in quality. We reported results of a pilot study using JPEG compression of 24-bit color endoscopic images. For that study, the result indicated that adequate compression ratios vary according to the lesion and that images could be compressed to between 31- and 99-fold smaller than the original size without an appreciable decline in quality. The purpose of this study was to expand upon the methodology of the previous sty with an eye towards application for the WWW, a medium which would expand both clinical and educational purposes of color medical imags. The results indicate that endoscopists are able to tolerate very significant compression of endoscopic images without loss of clinical image quality. This finding suggests that even 1 MB color images can be compressed to well under 30KB, which is considered a maximal tolerable image size for downloading on the WWW.

  3. Clinical study using novel endoscopic system for measuring size of gastrointestinal lesion

    PubMed Central

    Oka, Kiyoshi; Seki, Takeshi; Akatsu, Tomohiro; Wakabayashi, Takao; Inui, Kazuo; Yoshino, Junji

    2014-01-01

    AIM: To verify the performance of a lesion size measurement system through a clinical study. METHODS: Our proposed system, which consists of a conventional endoscope, an optical device, an optical probe, and a personal computer, generates a grid scale to measure the lesion size from an endoscopic image. The width of the grid scale is constantly adjusted according to the distance between the tip of the endoscope and lesion because the lesion size on an endoscopic image changes according to the distance. The shape of the grid scale was corrected to match the distortion of the endoscopic image. The distance was calculated using the amount of laser light reflected from the lesion through an optical probe inserted into the instrument channel of the endoscope. The endoscopist can thus measure the lesion size without contact by comparing the lesion with the size of the grid scale on the endoscopic image. (1) A basic test was performed to verify the relationship between the measurement error eM and the tilt angle of the endoscope; and (2) The sizes of three colon polyps were measured using our system during endoscopy. These sizes were immediately measured by scale after their removal. RESULTS: There was no error at α = 0°. In addition, the values of eM (mean ± SD) were 0.24 ± 0.11 mm (α = 10°), 0.90 ± 0.58 mm (α = 20°) and 2.31 ± 1.41 mm (α = 30°). According to these results, our system has been confirmed to measure accurately when the tilt angle is less than 20°. The measurement error was approximately 1 mm in the clinical study. Therefore, it was concluded that our proposed measurement system was also effective in clinical examinations. CONCLUSION: By combining simple optical equipment with a conventional endoscope, a quick and accurate system for measuring lesion size was established. PMID:24744595

  4. MEMS-based non-rotatory circumferential scanning optical probe for endoscopic optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Xu, Yingshun; Singh, Janak; Siang, Teo Hui; Ramakrishna, Kotlanka; Premchandran, C. S.; Sheng, Chen Wei; Kuan, Chuah Tong; Chen, Nanguang; Olivo, Malini C.; Sheppard, Colin J. R.

    2007-07-01

    In this paper, we present a non-rotatory circumferential scanning optical probe integrated with a MEMS scanner for in vivo endoscopic optical coherence tomography (OCT). OCT is an emerging optical imaging technique that allows high resolution cross-sectional imaging of tissue microstructure. To extend its usage to endoscopic applications, a miniaturized optical probe based on Microelectromechanical Systems (MEMS) fabrication techniques is currently desired. A 3D electrothermally actuated micromirror realized using micromachining single crystal silicon (SCS) process highlights its very large angular deflection, about 45 degree, with low driving voltage for safety consideration. The micromirror is integrated with a GRIN lens into a waterproof package which is compatible with requirements for minimally invasive endoscopic procedures. To implement circumferential scanning substantially for diagnosis on certain pathological conditions, such as Barret's esophagus, the micromirror is mounted on 90 degree to optical axis of GRIN lens. 4 Bimorph actuators that are connected to the mirror on one end via supporting beams and springs are selected in this micromirror design. When actuators of the micromirror are driven by 4 channels of sinusoidal waveforms with 90 degree phase differences, beam focused by a GRIN is redirected out of the endoscope by 45 degree tilting mirror plate and achieve circumferential scanning pattern. This novel driving method making full use of very large angular deflection capability of our micromirror is totally different from previously developed or developing micromotor-like rotatory MEMS device for circumferential scanning.

  5. Optic for industrial endoscope/borescope with narrow field of view and low distortion

    DOEpatents

    Stone, Gary F.; Trebes, James E.

    2005-08-16

    An optic for the imaging optics on the distal end of a flexible fiberoptic endoscope or rigid borescope inspection tool. The image coverage is over a narrow (<20 degrees) field of view with very low optical distortion (<5% pin cushion or barrel distortion), compared to the typical <20% distortion. The optic will permit non-contact surface roughness measurements using optical techniques. This optic will permit simultaneous collection of selected image plane data, which data can then be subsequently optically processed. The image analysis will yield non-contact surface topology data for inspection where access to the surface does not permit a mechanical styles profilometer verification of surface topology. The optic allows a very broad spectral band or range of optical inspection. It is capable of spectroscopic imaging and fluorescence induced imaging when a scanning illumination source is used. The total viewing angle for this optic is 10 degrees for the full field of view of 10 degrees, compared to 40-70 degrees full angle field of view of the conventional gradient index or GRIN's lens systems.

  6. [Development of a video image system for wireless capsule endoscopes based on DSP].

    PubMed

    Yang, Li; Peng, Chenglin; Wu, Huafeng; Zhao, Dechun; Zhang, Jinhua

    2008-02-01

    A video image recorder to record video picture for wireless capsule endoscopes was designed. TMS320C6211 DSP of Texas Instruments Inc. is the core processor of this system. Images are periodically acquired from Composite Video Broadcast Signal (CVBS) source and scaled by video decoder (SAA7114H). Video data is transported from high speed buffer First-in First-out (FIFO) to Digital Signal Processor (DSP) under the control of Complex Programmable Logic Device (CPLD). This paper adopts JPEG algorithm for image coding, and the compressed data in DSP was stored to Compact Flash (CF) card. TMS320C6211 DSP is mainly used for image compression and data transporting. Fast Discrete Cosine Transform (DCT) algorithm and fast coefficient quantization algorithm are used to accelerate operation speed of DSP and decrease the executing code. At the same time, proper address is assigned for each memory, which has different speed;the memory structure is also optimized. In addition, this system uses plenty of Extended Direct Memory Access (EDMA) to transport and process image data, which results in stable and high performance.

  7. Workspace definition for navigated control functional endoscopic sinus surgery

    NASA Astrophysics Data System (ADS)

    Gessat, Michael; Hofer, Mathias; Audette, Michael; Dietz, Andreas; Meixensberger, Jürgen; Stauß, Gero; Burgert, Oliver

    2007-03-01

    For the pre-operative definition of a surgical workspace for Navigated Control ® Functional Endoscopic Sinus Surgery (FESS), we developed a semi-automatic image processing system. Based on observations of surgeons using a manual system, we implemented a workflow-based engineering process that led us to the development of a system reducing time and workload spent during the workspace definition. The system uses a feature based on local curvature to align vertices of a polygonal outline along the bone structures defining the cavities of the inner nose. An anisotropic morphologic operator was developed solve problems arising from artifacts from noise and partial volume effects. We used time measurements and NASA's TLX questionnaire to evaluate our system.

  8. Experimental assessment of a 3-D plenoptic endoscopic imaging system.

    PubMed

    Le, Hanh N D; Decker, Ryan; Krieger, Axel; Kang, Jin U

    2017-01-01

    An endoscopic imaging system using a plenoptic technique to reconstruct 3-D information is demonstrated and analyzed in this Letter. The proposed setup integrates a clinical surgical endoscope with a plenoptic camera to achieve a depth accuracy error of about 1 mm and a precision error of about 2 mm, within a 25 mm × 25 mm field of view, operating at 11 frames per second.

  9. Experimental assessment of a 3-D plenoptic endoscopic imaging system

    PubMed Central

    Le, Hanh N. D.; Decker, Ryan; Krieger, Axel; Kang, Jin U.

    2017-01-01

    An endoscopic imaging system using a plenoptic technique to reconstruct 3-D information is demonstrated and analyzed in this Letter. The proposed setup integrates a clinical surgical endoscope with a plenoptic camera to achieve a depth accuracy error of about 1 mm and a precision error of about 2 mm, within a 25 mm × 25 mm field of view, operating at 11 frames per second. PMID:29449863

  10. Adaptive marker-free registration using a multiple point strategy for real-time and robust endoscope electromagnetic navigation.

    PubMed

    Luo, Xiongbiao; Wan, Ying; He, Xiangjian; Mori, Kensaku

    2015-02-01

    Registration of pre-clinical images to physical space is indispensable for computer-assisted endoscopic interventions in operating rooms. Electromagnetically navigated endoscopic interventions are increasingly performed at current diagnoses and treatments. Such interventions use an electromagnetic tracker with a miniature sensor that is usually attached at an endoscope distal tip to real time track endoscope movements in a pre-clinical image space. Spatial alignment between the electromagnetic tracker (or sensor) and pre-clinical images must be performed to navigate the endoscope to target regions. This paper proposes an adaptive marker-free registration method that uses a multiple point selection strategy. This method seeks to address an assumption that the endoscope is operated along the centerline of an intraluminal organ which is easily violated during interventions. We introduce an adaptive strategy that generates multiple points in terms of sensor measurements and endoscope tip center calibration. From these generated points, we adaptively choose the optimal point, which is the closest to its assigned the centerline of the hollow organ, to perform registration. The experimental results demonstrate that our proposed adaptive strategy significantly reduced the target registration error from 5.32 to 2.59 mm in static phantoms validation, as well as from at least 7.58 mm to 4.71 mm in dynamic phantom validation compared to current available methods. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope

    NASA Astrophysics Data System (ADS)

    Wall, R. Andrew; Barton, Jennifer K.

    2012-02-01

    A side-viewing, 2 mm diameter, surface magnifying chromoendoscopy (SMC)-optical coherence tomography (OCT) endoscope has been designed for simultaneous, non-destructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of mouse colon. A 30,000 element fiber bundle is combined with single mode fibers. The distal optics consist of a gradient-index lens and spacer to provide a magnification of 1 at a working distance of 1.58 mm in air, necessary to image the sample through a 0.23 mm thick outer glass envelope, and an aluminized right-angle prism fixed to the distal end of the GRIN lens assembly. The resulting 1:1 imaging system is capable of 3.9 μm lateral and 2.3 μm axial resolution in the OCT channel, and 125 lp/mm resolution across a 0.70 mm field of view in the SMC channel. The endoscope can perform high contrast crypt visualization, molecular imaging, and cross-sectional imaging of colon microstructure.

  12. Real-time high-velocity resolution color Doppler OCT

    NASA Astrophysics Data System (ADS)

    Westphal, Volker; Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    2001-05-01

    Color Doppler optical coherence tomography (CDOCT), also called Optical Doppler Tomography) is a noninvasive optical imaging technique, which allows for micron-scale physiological flow mapping simultaneous with morphological OCT imaging. Current systems for real-time endoscopic optical coherence tomography (EOCT) would be enhanced by the capability to visualize sub-surface blood flow for applications in early cancer diagnosis and the management of bleeding ulcers. Unfortunately, previous implementations of CDOCT have either been sufficiently computationally expensive (employing Fourier or Hilbert transform techniques) to rule out real-time imaging of flow, or have been restricted to imaging of excessively high flow velocities when used in real time. We have developed a novel Doppler OCT signal-processing strategy capable of imaging physiological flow rates in real time. This strategy employs cross-correlation processing of sequential A-scans in an EOCT image, as opposed to autocorrelation processing as described previously. To measure Doppler shifts in the kHz range using this technique, it was necessary to stabilize the EOCT interferometer center frequency, eliminate parasitic phase noise, and to construct a digital cross correlation unit able to correlate signals of megahertz bandwidth by a fixed lag of up to a few ms. The performance of the color Doppler OCT system was demonstrated in a flow phantom, demonstrating a minimum detectable flow velocity of ~0.8 mm/s at a data acquisition rate of 8 images/second (with 480 A-scans/image) using a handheld probe. Dynamic flow as well as using it freehanded was shown. Flow was also detectable in a phantom in combination with a clinical usable endoscopic probe.

  13. Conjugation of fiber-coupled wide-band light sources and acousto-optical spectral elements

    NASA Astrophysics Data System (ADS)

    Machikhin, Alexander; Batshev, Vladislav; Polschikova, Olga; Khokhlov, Demid; Pozhar, Vitold; Gorevoy, Alexey

    2017-12-01

    Endoscopic instrumentation is widely used for diagnostics and surgery. The imaging systems, which provide the hyperspectral information of the tissues accessible by endoscopes, are particularly interesting and promising for in vivo photoluminescence diagnostics and therapy of tumour and inflammatory diseases. To add the spectral imaging feature to standard video endoscopes, we propose to implement acousto-optical (AO) filtration of wide-band illumination of incandescent-lamp-based light sources. To collect maximum light and direct it to the fiber-optic light guide inside the endoscopic probe, we have developed and tested the optical system for coupling the light source, the acousto-optical tunable filter (AOTF) and the light guide. The system is compact and compatible with the standard endoscopic components.

  14. Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope

    NASA Astrophysics Data System (ADS)

    Wall, R. Andrew; Barton, Jennifer K.

    2012-08-01

    A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fiber bundle is combined with single mode fibers, for SMC and OCT imaging, respectively. The distal optics consist of a gradient-index lens and spacer to provide a 1× magnification at a working distance of 1.58 mm in air, necessary to image the sample through a 0.23-mm thick outer glass envelope, and an aluminized right-angle prism fixed to the distal end of the gradient-index lens assembly. The resulting 1∶1 imaging system is capable of 3.9-μm lateral and 2.3-μm axial resolution in the OCT channel, and 125-lp/mm resolution across a 0.70-mm field of view in the SMC channel. The endoscope can perform high contrast crypt visualization, molecular imaging, and cross-sectional imaging of colon microstructure.

  15. Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope

    PubMed Central

    Wall, R. Andrew

    2012-01-01

    Abstract. A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fiber bundle is combined with single mode fibers, for SMC and OCT imaging, respectively. The distal optics consist of a gradient-index lens and spacer to provide a 1× magnification at a working distance of 1.58 mm in air, necessary to image the sample through a 0.23-mm thick outer glass envelope, and an aluminized right-angle prism fixed to the distal end of the gradient-index lens assembly. The resulting 1∶1 imaging system is capable of 3.9-µm lateral and 2.3-µm axial resolution in the OCT channel, and 125-lp/mm resolution across a 0.70-mm field of view in the SMC channel. The endoscope can perform high contrast crypt visualization, molecular imaging, and cross-sectional imaging of colon microstructure. PMID:23224190

  16. Image-guided intervention in the human bile duct using scanning fiber endoscope system

    NASA Astrophysics Data System (ADS)

    Seibel, Eric J.; Jo, Javier A.; Melville, C. David; Johnston, Richard S.; Naumann, Christopher R.; Saunders, Michael D.

    2012-01-01

    Bile duct cancers are increasing in frequency while being difficult to diagnose. Currently available endoscopic imaging devices used in the biliary tree are low resolution with poor image quality, leading to inadequate evaluation of indeterminate biliary strictures. However, a new ultrathin and flexible cholangioscope system has been successfully demonstrated in a human subject. This mini-cholangioscope system uses a scanning fiber endoscope (SFE) as a forward-imaging guidewire, dimensions of 1.2-mm diameter and 3-m length. Full color video (500-line resolution at 30Hz) is the standard SFE imaging mode using spiral scanning of red, green, and blue laser light at low power. Image-guided operation of the biopsy forceps was demonstrated in healthy human bile ducts with and without saline flushing. The laser-based video imaging can be switched to various modes to enhance tissue markers of disease, such as widefield fluorescence and enhanced spectral imaging. In parallel work, biochemical discrimination of tissue health in pig bile duct has been accomplished using fiberoptic delivery of pulsed UV illumination and time-resolved autofluorescence spectroscopic measurements. Implementation of time-resolved fluorescence spectroscopy for biochemical assessment of the bile duct wall is being done through a secondary endoscopic channel. Preliminary results indicate that adequate SNR levels (> 30 dB) can be achieved through a 50 micron fiber, which could serve as an optical biopsy probe. The SFE is an ideal mini-cholangioscope for integration of both tissue and molecular specific image contrast in the future. This will provide the physician with unprecedented abilities to target biopsy locations and perform endoscopically-guided therapies.

  17. Optical design of an optical coherence tomography and multispectral fluorescence imaging endoscope to detect early stage ovarian cancer

    NASA Astrophysics Data System (ADS)

    Tate, Tyler; Keenan, Molly; Swan, Elizabeth; Black, John; Utzinger, Urs; Barton, Jennifer

    2014-12-01

    The five year survival rate for ovarian cancer is over 90% if early detection occurs, yet no effective early screening method exists. We have designed and are constructing a dual modality Optical Coherence Tomography (OCT) and Multispectral Fluorescence Imaging (MFI) endoscope to optically screen the Fallopian tube and ovary for early stage cancer. The endoscope reaches the ovary via the natural pathway of the vagina, cervix, uterus and Fallopian tube. In order to navigate the Fallopian tube the endoscope must have an outer diameter of 600 μm, be highly flexible, steerable, tracking and nonperforating. The imaging systems consists of six optical subsystems, two from OCT and four from MFI. The optical subsystems have independent and interrelated design criteria. The endoscope will be tested on realistic tissue models and ex vivo tissue to prove feasibility of future human trials. Ultimately the project aims to provide women the first effective ovarian cancer screening technique.

  18. An endoscopic fluorescence imaging system for simultaneous visual examination and photodetection of cancers

    NASA Astrophysics Data System (ADS)

    Wagnières, Georges A.; Studzinski, André P.; van den Bergh, Hubert E.

    1997-01-01

    We describe the design and performance tested during six years of clinical trials of a fluorescence endoscope for the detection and delineation of cancers in several hollow organs. The apparatus is based on the imaging of the laser-induced fluorescence that differs between a tumor and its surrounding normal tissue. The tests are carried out in the upper aerodigestive tract, the tracheobronchial tree, the esophagus, and the colon. In the three former cases an exogenous dye is used (Photofrin II), whereas in the latter case fluorescein molecules conjugated with monoclonal antibodies directed against carcinoembryonic antigen are injected. The decrease of native tissue autofluorescence observed in early cancers is also used for detecting lesions in the tracheobronchial tree. The fluorescence contrast between the tumor and surrounding normal tissue is enhanced by real time image processing. This is done by simultaneously recording the fluorescence image in two spectral domains, after which these two images are digitized and manipulated with a mathematical operator (look-up table) at video frequency. Moreover, the device that is described below allows for an immediate observation of the endoscopic area under white light illumination during fluorescence detection in order to localize the origin of the "positive" fluorescence signals. Typical results obtained in the tracheobronchial tree and in the colon are presented and the sources of false positives and false negatives are evaluated in terms of the fluorescent dye, tissue optical properties, and illumination optics.

  19. Endoscopic image-guided thermal therapy using targeted near infrared fluorescent gold nanorods (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Elson, Daniel S.

    2016-09-01

    We present an in vivo study of endoscopic fluorescence image-guided photothermal therapy of human oesophageal adenocarcinoma in a murine xenograft model, using intratumoural or intravenous gold nanorods functionalised with Cy5.5 and EGFR.

  20. History, Current Situation, and Future Development of Endoscopic Neurosurgery in China.

    PubMed

    Li, Chuzhong; Zhu, Haibo; Zong, Xuyi; Wang, Xinsheng; Gui, Songbai; Zhao, Peng; Zhang, Yazhuo

    2018-02-01

    During the past few decades, Chinese endoscopic neurosurgery has rapidly developed in synchrony with the rest of the world. The aim of this article is to review the development of Chinese endoscopic neurosurgery, including its birth, growth, current situation, and prospects. The history of Chinese endoscopic neurosurgery development can be divided into 3 stages: cognition and initial stage (1964-1995), exploration and maturity stage (1995-2006), and rapid development and promotion stage (2006-present). In the first stage, we mainly began to become aware of endoscopic neurosurgery from the translation and review of literature. In the mid to late 1990s, Chinese neurosurgery pioneers began using neuroendoscopic techniques. In the following decade, many leading neurosurgeons made persistent efforts to push the development of Chinese endoscopic neurosurgery forward, focusing on advocating for and promoting and popularizing neuroendoscopic technology. In the rapid development and promotion stage, many representative national and regional neurosurgical centers became skilled and efficient in the application of neuroendoscopic technology and became new advocates of the technology. The number of cases, level of technology, and treatment effectiveness are gradually nearing international standards. However, future development requires promotion of balanced development to decrease regional disparities, further strengthen international exchanges, follow the latest developments, and constantly innovate for continuous improvement. Following the dramatic efforts of several pioneers, development of Chinese endoscopic neurosurgery has been considerable, and it has become an important component of neurosurgery worldwide. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Image-Guided Biopsy in the Esophagus through Comprehensive Optical Frequency Domain Imaging and Laser Marking: A Study in Living Swine

    PubMed Central

    Suter, Melissa J.; Jillella, Priyanka A.; Vakoc, Benjamin J.; Halpern, Elkan F.; Mino-Kenudson, Mari; Lauwers, Gregory Y.; Bouma, Brett E.; Nishioka, Norman S.; Tearney, Guillermo J.

    2010-01-01

    Background Random biopsy esophageal surveillance can be subject to sampling errors, resulting in diagnostic uncertainty. Optical frequency domain imaging (OFDI) is a high-speed, three-dimensional endoscopic microscopy technique. When deployed through a balloon-centering catheter, OFDI can automatically image the entire distal esophagus (6.0 cm length) in approximately 2 minutes. Objective To test a new platform for guided biopsy that allows the operator to select target regions of interest on an OFDI dataset, and then use a laser to mark the esophagus at corresponding locations. The specific goals include determining the optimal laser parameters, testing the accuracy of the laser marking process, evaluating the endoscopic visibility of the laser marks, and assessing the amount of mucosal damage produced by the laser. Design Experimental study conducted in five swine in vivo. Setting Massachusetts General Hospital. Main Outcome Measurements Success rate, including endoscopic visibility of laser marks and accuracy of the laser marking process for selected target sites, and extent of the thermal damage caused by the laser marks. Results All of the laser-induced marks were visible by endoscopy. Target locations were correctly marked with a success rate of 97.07% (95% CI, 89.8%-99.7%). Thermal damage was limited to the superficial layers of the mucosa and was observed to partially heal within 2 days. Limitations An animal study with artificially placed targets to simulate pathology. Conclusions The study demonstrates that laser marking of esophageal sites identified in comprehensive OFDI datasets is feasible and can be performed with sufficient accuracy, precision, and visibility to guide biopsy in vivo. PMID:19879573

  2. A standardized imaging protocol for the endoscopic prediction of dysplasia within sessile serrated polyps (with video).

    PubMed

    Tate, David J; Jayanna, Mahesh; Awadie, Halim; Desomer, Lobke; Lee, Ralph; Heitman, Steven J; Sidhu, Mayenaaz; Goodrick, Kathleen; Burgess, Nicholas G; Mahajan, Hema; McLeod, Duncan; Bourke, Michael J

    2018-01-01

    Dysplasia within sessile serrated polyps (SSPs) is difficult to detect and may be mistaken for an adenoma, risking incomplete resection of the background serrated tissue, and is strongly implicated in interval cancer after colonoscopy. The use of endoscopic imaging to detect dysplasia within SSPs has not been systematically studied. Consecutively detected SSPs ≥8 mm in size were evaluated by using a standardized imaging protocol at a tertiary-care endoscopy center over 3 years. Lesions suspected as SSPs were analyzed with high-definition white light then narrow-band imaging. A demarcated area with a neoplastic pit pattern (Kudo type III/IV, NICE type II) was sought among the serrated tissue. If this was detected, the lesion was labeled dysplastic (sessile serrated polyp with dysplasia); if not, it was labeled non-dysplastic (sessile serrated polyp without dysplasia). Histopathology was reviewed by 2 blinded specialist GI pathologists. A total of 141 SSPs were assessed in 83 patients. Median lesion size was 15.0 mm (interquartile range 10-20), and 54.6% were in the right side of the colon. Endoscopic evidence of dysplasia was detected in 36 of 141 (25.5%) SSPs; of these, 5 of 36 (13.9%) lacked dysplasia at histopathology. Two of 105 (1.9%) endoscopically designated non-dysplastic SSPs had dysplasia at histopathology. Endoscopic imaging, therefore, had an accuracy of 95.0% (95% confidence interval [CI], 90.1%-97.6%) and a negative predictive value of 98.1% (95% CI, 92.6%-99.7%) for detection of dysplasia within SSPs. Dysplasia within SSPs can be detected accurately by using a simple, broadly applicable endoscopic imaging protocol that allows complete resection. Independent validation of this protocol and its dissemination to the wider endoscopic community may have a significant impact on rates of interval cancer. (Clinical trial registration number: NCT03100552.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  3. Design of the computerized 3D endoscopic imaging system for delicate endoscopic surgery.

    PubMed

    Song, Chul-Gyu; Kang, Jin U

    2011-02-01

    This paper describes a 3D endoscopic video system designed to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. In a comparison of the polarized and conventional electric shutter-type stereo imaging systems, the former was found to be superior in terms of both accuracy and speed for suturing and for the loop pass test. Among the groups performing loop passing and suturing, there was no significant difference in the task performance between the 2D and 3D modes, however, suturing was performed 15% (p < 0.05) faster in 3D mode by both groups. The results of our experiments show that the proposed 3D endoscopic system has a sufficiently wide viewing angle and zone for multi-viewing.

  4. Scanning Fiber Endoscope Improves Detection of 5-Aminolevulinic Acid-Induced Protoporphyrin IX Fluorescence at the Boundary of Infiltrative Glioma.

    PubMed

    Belykh, Evgenii; Miller, Eric J; Hu, Danying; Martirosyan, Nikolay L; Woolf, Eric C; Scheck, Adrienne C; Byvaltsev, Vadim A; Nakaji, Peter; Nelson, Leonard Y; Seibel, Eric J; Preul, Mark C

    2018-05-01

    Fluorescence-guided surgery with protoporphyrin IX (PpIX) as a photodiagnostic marker is gaining acceptance for resection of malignant gliomas. Current wide-field imaging technologies do not have sufficient sensitivity to detect low PpIX concentrations. We evaluated a scanning fiber endoscope (SFE) for detection of PpIX fluorescence in gliomas and compared it to an operating microscope (OPMI) equipped with a fluorescence module and to a benchtop confocal laser scanning microscope (CLSM). 5-Aminolevulinic acid-induced PpIX fluorescence was assessed in GL261-Luc2 cells in vitro and in vivo after implantation in mouse brains, at an invading glioma growth stage, simulating residual tumor. Intraoperative fluorescence of high and low PpIX concentrations in normal brain and tumor regions with SFE, OPMI, CLSM, and histopathology were compared. SFE imaging of PpIX correlated to CLSM at the cellular level. PpIX accumulated in normal brain cells but significantly less than in glioma cells. SFE was more sensitive to accumulated PpIX in fluorescent brain areas than OPMI (P < 0.01) and dramatically increased imaging time (>6×) before tumor-to-background contrast was diminished because of photobleaching. SFE provides new endoscopic capabilities to view PpIX-fluorescing tumor regions at cellular resolution. SFE may allow accurate imaging of 5-aminolevulinic acid labeling of gliomas and other tumor types when current detection techniques have failed to provide reliable visualization. SFE was significantly more sensitive than OPMI to low PpIX concentrations, which is relevant to identifying the leading edge or metastasizing cells of malignant glioma or to treating low-grade gliomas. This new application has the potential to benefit surgical outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. 3D imaging with a single-aperture 3-mm objective lens: concept, fabrication, and test

    NASA Astrophysics Data System (ADS)

    Korniski, Ronald; Bae, Sam Y.; Shearn, Michael; Manohara, Harish; Shahinian, Hrayr

    2011-10-01

    There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the- shelf (COTS) components including the ones used in the endoscope objective.

  6. 3D Imaging with a Single-Aperture 3-mm Objective Lens: Concept, Fabrication and Test

    NASA Technical Reports Server (NTRS)

    Korniski, Ron; Bae, Sam Y.; Shearn, Mike; Manohara, Harish; Shahinian, Hrayr

    2011-01-01

    There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the-shelf (COTS) components including the ones used in the endoscope objective.

  7. Quantitative, Noninvasive Imaging of DNA Damage in Vivo of Prostate Cancer Therapy by Transurethral Photoacoustic (TUPA) Imaging

    DTIC Science & Technology

    2014-10-01

    provided the funding to devise a trans-urethral photoacoustic endoscope , which has the potential to obtain higher resolution by using a high frequency...modality. This grant has provided the funding to devise a trans-urethral photoacoustic endoscope , which has the potential to obtain higher resolution by...multimode optical fiber (UM22-600, Thorlabs) was placed which is positioned statically along the axis of the endoscope . A parabolic acoustic

  8. Design and characterization of an optimized simultaneous color and near-infrared fluorescence rigid endoscopic imaging system

    NASA Astrophysics Data System (ADS)

    Venugopal, Vivek; Park, Minho; Ashitate, Yoshitomo; Neacsu, Florin; Kettenring, Frank; Frangioni, John V.; Gangadharan, Sidhu P.; Gioux, Sylvain

    2013-12-01

    We report the design, characterization, and validation of an optimized simultaneous color and near-infrared (NIR) fluorescence rigid endoscopic imaging system for minimally invasive surgery. This system is optimized for illumination and collection of NIR wavelengths allowing the simultaneous acquisition of both color and NIR fluorescence at frame rates higher than 6.8 fps with high sensitivity. The system employs a custom 10-mm diameter rigid endoscope optimized for NIR transmission. A dual-channel light source compatible with the constraints of an endoscope was built and includes a plasma source for white light illumination and NIR laser diodes for fluorescence excitation. A prism-based 2-CCD camera was customized for simultaneous color and NIR detection with a highly efficient filtration scheme for fluorescence imaging of both 700- and 800-nm emission dyes. The performance characterization studies indicate that the endoscope can efficiently detect fluorescence signal from both indocyanine green and methylene blue in dimethyl sulfoxide at the concentrations of 100 to 185 nM depending on the background optical properties. Finally, we performed the validation of this imaging system in vivo during a minimally invasive procedure for thoracic sentinel lymph node mapping in a porcine model.

  9. Identification of lesion images from gastrointestinal endoscope based on feature extraction of combinational methods with and without learning process.

    PubMed

    Liu, Ding-Yun; Gan, Tao; Rao, Ni-Ni; Xing, Yao-Wen; Zheng, Jie; Li, Sang; Luo, Cheng-Si; Zhou, Zhong-Jun; Wan, Yong-Li

    2016-08-01

    The gastrointestinal endoscopy in this study refers to conventional gastroscopy and wireless capsule endoscopy (WCE). Both of these techniques produce a large number of images in each diagnosis. The lesion detection done by hand from the images above is time consuming and inaccurate. This study designed a new computer-aided method to detect lesion images. We initially designed an algorithm named joint diagonalisation principal component analysis (JDPCA), in which there are no approximation, iteration or inverting procedures. Thus, JDPCA has a low computational complexity and is suitable for dimension reduction of the gastrointestinal endoscopic images. Then, a novel image feature extraction method was established through combining the algorithm of machine learning based on JDPCA and conventional feature extraction algorithm without learning. Finally, a new computer-aided method is proposed to identify the gastrointestinal endoscopic images containing lesions. The clinical data of gastroscopic images and WCE images containing the lesions of early upper digestive tract cancer and small intestinal bleeding, which consist of 1330 images from 291 patients totally, were used to confirm the validation of the proposed method. The experimental results shows that, for the detection of early oesophageal cancer images, early gastric cancer images and small intestinal bleeding images, the mean values of accuracy of the proposed method were 90.75%, 90.75% and 94.34%, with the standard deviations (SDs) of 0.0426, 0.0334 and 0.0235, respectively. The areas under the curves (AUCs) were 0.9471, 0.9532 and 0.9776, with the SDs of 0.0296, 0.0285 and 0.0172, respectively. Compared with the traditional related methods, our method showed a better performance. It may therefore provide worthwhile guidance for improving the efficiency and accuracy of gastrointestinal disease diagnosis and is a good prospect for clinical application. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Multispectral therapeutic endoscopy imaging and intervention

    NASA Astrophysics Data System (ADS)

    Bala, John L.; Schwaitzberg, Steven D.

    2007-02-01

    With the debut of antibiotic drug therapy, and as a result of its ease of use and general success in treating infection, drugs have become the treatment of choice for most bacterial infections. However, the advent of multiple, very aggressive drug-resistant bacteria, an increasing population which cannot tolerate drugs, and the high cost of drug therapy suggest that a new modality for treating infections is needed. The complex interplay of clonal spread, persistence, transfer of resistance elements and cell-to-cell interaction all contribute to the difficulty in developing drugs to treat new antibiotic-resistant bacterial strains. A dynamic non-drug system, using extant pulsed ultraviolet lightwave technology to kill infection, is being developed to destroy pathogens. This paper theorizes that the shock effect of pulsed xenon's high energy ultraviolet pulses at wavelengths between 250-270nm separates the bacteria's DNA bands, and, subsequently, destroys them. Preliminary laboratory tests have demonstrated the ability of the technology to destroy Staphylococcus aureus, Pseudomonas aeruginosa Escherichia coli, Helicobacter pylori, Acinetobacter baumannii, Klebsiella punemonia, Bacillus subtillis, and Aspergillus fumigates at penetration depths of greater than 3mm in fluids with 100% effectiveness in less than five seconds of exposure to pulsed xenon lightwaves. Micro Invasive Technology, Inc is developing .pulsed xenon therapeutic catheters and endoscopic instruments for internal antimicrobial eradication and topographical devices for prophylactic wound, burn and surgical entrance/exit site sterilization. Pulsed Xenon light sources have a broad optical spectrum (190-1200nm), and can generate light pulses with sufficient energy for combined imaging and therapeutic intervention by multiplexing a fiber optic pathway into the body. In addition, Pulsed Xenon has proven ability to activate photo reactive dyes; share endoscopic lightguides with lasers while, simultaneously, capturing high quality visual and activated video images.

  11. Feasibility of Obtaining Quantitative 3-Dimensional Information Using Conventional Endoscope: A Pilot Study

    PubMed Central

    Hyun, Jong Jin; Keum, Bora; Seo, Yeon Seok; Kim, Yong Sik; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck; Ryu, Ho Sang; Lim, Jong-Wook; Woo, Dong-Gi; Kim, Young-Joong; Lim, Myo-Taeg

    2012-01-01

    Background/Aims Three-dimensional (3D) imaging is gaining popularity and has been partly adopted in laparoscopic surgery or robotic surgery but has not been applied to gastrointestinal endoscopy. As a first step, we conducted an experiment to evaluate whether images obtained by conventional gastrointestinal endoscopy could be used to acquire quantitative 3D information. Methods Two endoscopes (GIF-H260) were used in a Borrmann type I tumor model made of clay. The endoscopes were calibrated by correcting the barrel distortion and perspective distortion. Obtained images were converted to gray-level image, and the characteristics of the images were obtained by edge detection. Finally, data on 3D parameters were measured by using epipolar geometry, two view geometry, and pinhole camera model. Results The focal length (f) of endoscope at 30 mm was 258.49 pixels. Two endoscopes were fixed at predetermined distance, 12 mm (d12). After matching and calculating disparity (v2-v1), which was 106 pixels, the calculated length between the camera and object (L) was 29.26 mm. The height of the object projected onto the image (h) was then applied to the pinhole camera model, and the result of H (height and width) was 38.21 mm and 41.72 mm, respectively. Measurements were conducted from 2 different locations. The measurement errors ranged from 2.98% to 7.00% with the current Borrmann type I tumor model. Conclusions It was feasible to obtain parameters necessary for 3D analysis and to apply the data to epipolar geometry with conventional gastrointestinal endoscope to calculate the size of an object. PMID:22977798

  12. Correction of motion artifacts in endoscopic optical coherence tomography and autofluorescence images based on azimuthal en face image registration.

    PubMed

    Abouei, Elham; Lee, Anthony M D; Pahlevaninezhad, Hamid; Hohert, Geoffrey; Cua, Michelle; Lane, Pierre; Lam, Stephen; MacAulay, Calum

    2018-01-01

    We present a method for the correction of motion artifacts present in two- and three-dimensional in vivo endoscopic images produced by rotary-pullback catheters. This method can correct for cardiac/breathing-based motion artifacts and catheter-based motion artifacts such as nonuniform rotational distortion (NURD). This method assumes that en face tissue imaging contains slowly varying structures that are roughly parallel to the pullback axis. The method reduces motion artifacts using a dynamic time warping solution through a cost matrix that measures similarities between adjacent frames in en face images. We optimize and demonstrate the suitability of this method using a real and simulated NURD phantom and in vivo endoscopic pulmonary optical coherence tomography and autofluorescence images. Qualitative and quantitative evaluations of the method show an enhancement of the image quality. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  13. Initial experimental evaluation of wireless capsule endoscopes in the bladder: implications for capsule cystoscopy.

    PubMed

    Gettman, Matthew T; Swain, Paul

    2009-05-01

    Cystoscopy remains one of the most important diagnostic procedures for the lower urinary tract. Wireless capsule endoscopy was introduced in the 1990s but use to date is limited to gastroenterology. We evaluated the feasibility in the pig model of using wireless capsule endoscopes (WCEs) for cystoscopy. Experimental evaluation of capsule cystoscopy was performed in a 50-kg farm pig. The capsule was deployed into the bladder through a custom access sheath. Images were continuously transmitted at a rate of four frames per second to a laptop computer and processed using proprietary software. Manipulation of the WCE within the bladder was performed using a set protocol. The animal was then euthanized and gross inspection was performed. We measured the ability to deploy and manipulate the capsule within the bladder. Feasibility of capturing and retrieving images in real time was also assessed. The WCE was efficiently deployed and manipulated within the bladder passively and with the use of external magnets. The entire bladder mucosa was visualized. Real-time image transmission and capture were successful. No complications were seen during capsule cystoscopy. Minor urethral bleeding was observed after the experiment, likely related to placement of the access sheath required for deployment of the WCE. Limitations are that the evaluation of WCE was performed in the pig model, in only one female animal, using a nonsurvival approach. Furthermore, the study was not designed to differentiate normal from abnormal mucosal findings and focused solely on inspection of the bladder. This report suggests that cystoscopy with a WCE is feasible. With this device, all aspects of the bladder mucosa could be visualized, and ongoing technologic and procedural developments are warranted for this new approach.

  14. Radiological and endoscopic imaging methods in the management of cystic pancreatic neoplasms.

    PubMed

    Aslan, Ahmet; Inan, Ibrahim; Orman, Süleyman; Aslan, Mine; Acar, Murat

    2017-01-01

    The management of cystic pancreatic neoplasm (CPN) is a clinical dilemma because of its clinical presentations and malignant potential. Surgery is the best treatment choice ; however, pancreatic surgery still has high complication rates, even in experienced centers. Imaging methods have a definitive role in the management of CPN and computed tomography, magnetic resonance imaging, and endoscopic ultrasonography are the preferred methods since they can reveal the suspicious features for malignancy. Therefore, radiologists, gastroenterologists, endoscopists, and surgeons should be aware of the common features of CPN, its discrete presentations on imaging methods, and the limitations of these modalities in the management of the disease. This study aims to review the radiological and endoscopic imaging methods used for the management of CPN. © Acta Gastro-Enterologica Belgica.

  15. Imaging camera system of OYGBR-phosphor-based white LED lighting

    NASA Astrophysics Data System (ADS)

    Kobashi, Katsuya; Taguchi, Tsunemasa

    2005-03-01

    The near-ultraviolet (nUV) white LED approach is analogous to three-color fluorescent lamp technology, which is based on the conversion of nUV radiation to visible light via the photoluminescence process in phosphor materials. The nUV light is not included in the white light generation from nUV-based white LED devices. This technology can thus provide a higher quality of white light than the blue and YAG method. A typical device demonstrates white luminescence with Tc=3,700 K, Ra > 93, K > 40 lm/W and chromaticity (x, y) = (0.39, 0.39), respectively. The orange, yellow, green and blue OYGB) or orange, yellow, red, green and blue (OYRGB) device shows a luminescence spectrum broader than of an RGB white LED and a better color rendering index. Such superior luminous characteristics could be useful for the application of several kinds of endoscope. We have shown the excellent pictures of digestive organs in a stomach of a dog due to the strong green component and high Ra.

  16. Pilot randomized crossover study comparing the efficacy of transnasal disposable endosheath with standard endoscopy to detect Barrett's esophagus.

    PubMed

    Shariff, Mohammed K; Varghese, Sibu; O'Donovan, Maria; Abdullahi, Zarah; Liu, Xinxue; Fitzgerald, Rebecca C; di Pietro, Massimiliano

    2016-02-01

    The transnasal endosheath endoscope is a new disposable technology with potential applicability to the primary care setting. The aim of this study was to evaluate the efficacy of transnasal endosheath endoscopy (TEE) for the detection of Barrett's esophagus, by comparing the diagnostic accuracy of TEE with that of standard endoscopy. This was a prospective, randomized, crossover study performed in a single tertiary referral center. Consecutive patients undergoing surveillance for Barrett's esophagus or referred for diagnostic assessment were recruited. All patients were randomized to undergo TEE followed by standard endoscopy or the reverse. Endoscopy experiences and patient preferences were evaluated using a questionnaire. Endoscopic and histologic diagnosis of Barrett's esophagus, and optical image quality of both endoscopic procedures, were compared. A total of 21 of 25 patients completed the study. TEE had sensitivity and specificity of 100 % for an endoscopic diagnosis of Barrett's esophagus, and of 66.7 % and 100 %, respectively, for the histologic diagnosis of Barrett's esophagus. The mean optical quality of standard endoscopy was significantly better than that of TEE (7.11 ± 0.42 vs. 4.06 ± 0.27; P < 0.0001). However, following endoscopy, patients reported a significantly better experience with TEE compared with standard endoscopy (7.05 ± 0.49 vs. 4.35 ± 0.53; P = 0.0006), with 60 % preferring TEE and 25 % preferring sedated standard endoscopy. In this study, TEE had equal accuracy for an endoscopic diagnosis of Barrett's esophagus compared with standard endoscopy, at the expense of reduced image quality and a lower yield of intestinal metaplasia on biopsy. TEE was better tolerated and preferred by patients. Hence, TEE needs further evaluation in primary care as an initial diagnostic tool. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Hyperspectral fluorescence imaging system for biomedical diagnostics

    NASA Astrophysics Data System (ADS)

    Martin, Matthew E.; Wabuyele, Musundi B.; Panjehpour, Masoud; Phan, Mary N.; Overholt, Bergein F.; Vo-Dinh, Tuan

    2006-02-01

    An advanced hyper-spectral imaging (HSI) system has been developed for use in medical diagnostics. One such diagnostic, esophageal cancer is diagnosed currently through biopsy and subsequent pathology. The end goal of this research is to develop an optical-based technique to assist or replace biopsy. In this paper, we demonstrate an instrument that has the capability to optically diagnose cancer in laboratory mice. We have developed a real-time HSI system based on state-of-the-art liquid crystal tunable filter (LCTF) technology coupled to an endoscope. This unique HSI technology is being developed to obtain spatially resolved images of the slight differences in luminescent properties of normal versus tumorous tissues. In this report, an in-vivo mouse study is shown. A predictive measure of cancer for the mice studied is developed and shown. It is hoped that the results of this study will lead to advances in the optical diagnosis of esophageal cancer in humans.

  18. Real-time microstructural and functional imaging and image processing in optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Westphal, Volker

    Optical Coherence Tomography (OCT) is a noninvasive optical imaging technique that allows high-resolution cross-sectional imaging of tissue microstructure, achieving a spatial resolution of about 10 mum. OCT is similar to B-mode ultrasound (US) except that it uses infrared light instead of ultrasound. In contrast to US, no coupling gel is needed, simplifying the image acquisition. Furthermore, the fiber optic implementation of OCT is compatible with endoscopes. In recent years, the transition from slow imaging, bench-top systems to real-time clinical systems has been under way. This has lead to a variety of applications, namely in ophthalmology, gastroenterology, dermatology and cardiology. First, this dissertation will demonstrate that OCT is capable of imaging and differentiating clinically relevant tissue structures in the gastrointestinal tract. A careful in vitro correlation study between endoscopic OCT images and corresponding histological slides was performed. Besides structural imaging, OCT systems were further developed for functional imaging, as for example to visualize blood flow. Previously, imaging flow in small vessels in real-time was not possible. For this research, a new processing scheme similar to real-time Doppler in US was introduced. It was implemented in dedicated hardware to allow real-time acquisition and overlayed display of blood flow in vivo. A sensitivity of 0.5mm/s was achieved. Optical coherence microscopy (OCM) is a variation of OCT, improving the resolution even further to a few micrometers. Advances made in the OCT scan engine for the Doppler setup enabled real-time imaging in vivo with OCM. In order to generate geometrical correct images for all the previous applications in real-time, extensive image processing algorithms were developed. Algorithms for correction of distortions due to non-telecentric scanning, nonlinear scan mirror movements, and refraction were developed and demonstrated. This has led to interesting new applications, as for example in imaging of the anterior segment of the eye.

  19. An enhanced narrow-band imaging method for the microvessel detection

    NASA Astrophysics Data System (ADS)

    Yu, Feng; Song, Enmin; Liu, Hong; Wan, Youming; Zhu, Jun; Hung, Chih-Cheng

    2018-02-01

    A medical endoscope system combined with the narrow-band imaging (NBI), has been shown to be a superior diagnostic tool for early cancer detection. The NBI can reveal the morphologic changes of microvessels in the superficial cancer. In order to improve the conspicuousness of microvessel texture, we propose an enhanced NBI method to improve the conspicuousness of endoscopic images. To obtain the more conspicuous narrow-band images, we use the edge operator to extract the edge information of the narrow-band blue and green images, and give a weight to the extracted edges. Then, the weighted edges are fused with the narrow-band blue and green images. Finally, the displayed endoscopic images are reconstructed with the enhanced narrow-band images. In addition, we evaluate the performance of enhanced narrow-band images with different edge operators. Experimental results indicate that the Sobel and Canny operators achieve the best performance of all. Compared with traditional NBI method of Olympus company, our proposed method has more conspicuous texture of microvessel.

  20. In vivo miniature robots for natural orifice surgery: State of the art and future perspectives.

    PubMed

    Tiwari, Manish M; Reynoso, Jason F; Lehman, Amy C; Tsang, Albert W; Farritor, Shane M; Oleynikov, Dmitry

    2010-06-27

    Natural orifice translumenal endoscopic surgery (NOTES) is the integration of laparoscopic minimally invasive surgery techniques with endoscopic technology. Despite the advances in NOTES technology, the approach presents several unique instrumentation and technique-specific challenges. Current flexible endoscopy platforms for NOTES have several drawbacks including limited stability, triangulation and dexterity, and lack of adequate visualization, suggesting the need for new and improved instrumentation for this approach. Much of the current focus is on the development of flexible endoscopy platforms that incorporate robotic technology. An alternative approach to access the abdominal viscera for either a laparoscopic or NOTES procedure is the use of small robotic devices that can be implanted in an intracorporeal manner. Multiple, independent, miniature robots can be simultaneously inserted into the abdominal cavity to provide a robotic platform for NOTES surgery. The capabilities of the robots include imaging, retraction, tissue and organ manipulation, and precise maneuverability in the abdominal cavity. Such a platform affords several advantages including enhanced visualization, better surgical dexterity and improved triangulation for NOTES. This review discusses the current status and future perspectives of this novel miniature robotics platform for the NOTES approach. Although these technologies are still in pre-clinical development, a miniature robotics platform provides a unique method for addressing the limitations of minimally invasive surgery, and NOTES in particular.

  1. The utility of cadaver dissection in endoscopic sinus surgery training courses.

    PubMed

    Zuckerman, Jodi D; Wise, Sarah K; Rogers, G Aaron; Senior, Brent A; Schlosser, Rodney J; DelGaudio, John M

    2009-01-01

    Understanding paranasal sinus anatomy is crucial for successful outcomes in endoscopic sinus surgery (ESS). This study was designed to evaluate subjective and objective differences in ESS cadaver dissections among participants of varying experience levels in association with the use of image guidance and computer-aided technologies in a physician training cadaver dissection laboratory. Participants in a 2-day cadaver dissection course completed daily predissection surveys evaluating subjective comfort with ESS. Pre- and postdissection computer tomography (CT) scans assessed completeness of dissection. Images were analyzed for maxillary antrostomy, frontal and sphenoid sinusotomy, residual ethmoid cells and partitions, and residual frontal recess cells. Fifty-one sides were dissected. Participant comfort increased significantly from day 1 to 2 for overall ESS (p = 0.001) and for individual sinuses (p < 0.001 to p = 0.047). Participants with more years in practice had fewer unopened ethmoid cells (p = 0.015) and frontal recess cells (p = 0.014) on dissection day 1. Participants with increased comfort in ethmoid dissection had fewer retained ethmoid partitions on day 1 (p = 0.017). Observed differences on dissection day 1 for unopened ethmoid and frontal recess cells and retained ethmoid partitions were not present on day 2. No significant differences were found based on use of image guidance for any parameter. Surgeons with increased comfort and more years in practice had more complete endoscopic cadaver dissections initially. Differences among participants diminished on dissection day 2, indicating the ability to review postdissection CT scans may improve surgeon comfort level and completeness of dissection.

  2. Correction of rotational distortion for catheter-based en face OCT and OCT angiography

    PubMed Central

    Ahsen, Osman O.; Lee, Hsiang-Chieh; Giacomelli, Michael G.; Wang, Zhao; Liang, Kaicheng; Tsai, Tsung-Han; Potsaid, Benjamin; Mashimo, Hiroshi; Fujimoto, James G.

    2015-01-01

    We demonstrate a computationally efficient method for correcting the nonuniform rotational distortion (NURD) in catheter-based imaging systems to improve endoscopic en face optical coherence tomography (OCT) and OCT angiography. The method performs nonrigid registration using fiducial markers on the catheter to correct rotational speed variations. Algorithm performance is investigated with an ultrahigh-speed endoscopic OCT system and micromotor catheter. Scan nonuniformity is quantitatively characterized, and artifacts from rotational speed variations are significantly reduced. Furthermore, we present endoscopic en face OCT and OCT angiography images of human gastrointestinal tract in vivo to demonstrate the image quality improvement using the correction algorithm. PMID:25361133

  3. Optic for an endoscope/borescope having high resolution and narrow field of view

    DOEpatents

    Stone, Gary F.; Trebes, James E.

    2003-10-28

    An optic having optimized high spatial resolution, minimal nonlinear magnification distortion while at the same time having a limited chromatic focal shift or chromatic aberrations. The optic located at the distal end of an endoscopic inspection tool permits a high resolution, narrow field of view image for medical diagnostic applications, compared to conventional optics for endoscopic instruments which provide a wide field of view, low resolution image. The image coverage is over a narrow (<20 degrees) field of view with very low optical distortion (<5% pin cushion or barrel distortion. The optic is also optimized for best color correction as well as to aid medical diagnostics.

  4. Preliminary experience with 4K ultra-high definition endoscope: analysis of pros and cons in skull base surgery.

    PubMed

    Rigante, M; La Rocca, G; Lauretti, L; D'Alessandris, G Q; Mangiola, A; Anile, C; Olivi, A; Paludetti, G

    2017-06-01

    During the last two decades endoscopic skull base surgery observed a continuous technical and technological development 3D endoscopy and ultra High Definition (HD) endoscopy have provided great advances in terms of visualisation and spatial resolution. Ultra-high definition (UHD) 4K systems, recently introduced in the clinical practice, will shape next steps forward especially in skull base surgery field. Patients were operated on through transnasal transsphenoidal endoscopic approaches performed using Olympus NBI 4K UHD endoscope with a 4 mm 0° Ultra Telescope, 300 W xenon lamp (CLV-S400) predisposed for narrow band imaging (NBI) technology connected through a camera head to a high-quality control unit (OTV-S400 - VISERA 4K UHD) (Olympus Corporation, Tokyo, Japan). Two screens are used, one 31" Monitor - (LMD-X310S) and one main ultra-HD 55" screen optimised for UHD image reproduction (LMD-X550S). In selected cases, we used a navigation system (Stealthstation S7, Medtronic, Minneapolis, MN, US). We evaluated 22 pituitary adenomas (86.3% macroadenomas; 13.7% microadenomas). 50% were not functional (NF), 22.8% GH, 18.2% ACTH, 9% PRL-secreting. Three of 22 were recurrences. In 91% of cases we achieved total removal, while in 9% near total resection. A mean follow-up of 187 days and average length of hospitalisation was 3.09 ± 0.61 days. Surgical duration was 128.18± 30.74 minutes. We experienced only 1 case of intraoperative low flow fistula with no further complications. None of the cases required any post- or intraoperative blood transfusion. The visualisation and high resolution of the operative field provided a very detailed view of all anatomical structures and pathologies allowing an improvement in safety and efficacy of the surgical procedure. The operative time was similar to the standard 2D HD and 3D procedures and the physical strain was also comparable to others in terms of ergonomics and weight. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  5. Therapeutic aspects of endoscopic ultrasound

    NASA Astrophysics Data System (ADS)

    Woodward, Timothy A.

    1999-06-01

    Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.

  6. The effect of light intensity on image quality in endoscopic ear surgery.

    PubMed

    McCallum, R; McColl, J; Iyer, A

    2018-05-16

    Endoscopic ear surgery is a rapidly developing field with many advantages. But endoscopes can reach temperatures of over 110°C at the tip, raising safety concerns. Reducing the intensity of the light source reduces temperatures produced. However, quality of images at lower light intensities has not yet been studied. We set out to study the effect of light intensity on image quality in EES. Prospective study of patients undergoing EES from April to October 2016. Consecutive images of the same operative field at 10%, 30%, 50% and 100% light intensities were taken. Eight international experts were asked to each evaluate 100 anonymised, randomised images. District General Hospital. Twenty patients. Images were evaluated on a 5-point Likert scale (1 = significantly worse than average; 5 = significantly better than average) for detail of anatomy; colour contrast; overall quality; and suitability for operating. Mean scores for photographs at 10%, 30%, 50% and 100% light intensity were 3.22 (SD 0.93), 3.15 (SD 0.84), 3.08 (SD 0.88) and 3.10 (SD 0.86), respectively. In ANOVA models for the scores on each of the scales (anatomy, colour contrast, overall quality and suitability for operating), the effects of rater and patient were highly significant (P < .0005) but light intensity was non-significant (P = .34, .32, .21, .15, respectively). Images taken during surgery by our endoscope and operative camera have no loss of quality when taken at lower light intensities. We recommend the surgeon considers use of lower light intensities in endoscopic ear surgery. © 2018 John Wiley & Sons Ltd.

  7. Oblique incidence reflectometry: optical models and measurements using a side-viewing gradient index lens-based endoscopic imaging system

    NASA Astrophysics Data System (ADS)

    Wall, R. Andrew; Barton, Jennifer K.

    2014-06-01

    A side-viewing, 2.3-mm diameter oblique incidence reflectometry endoscope has been designed to obtain optical property measurements of turbid samples. Light from a single-mode fiber is relayed obliquely onto the tissue with a gradient index lens-based distal optics assembly and the resulting diffuse reflectance profile is imaged and collected with a 30,000 element, 0.72 mm clear aperture fiber bundle. Sampling the diffuse reflectance in two-dimensions allows for fitting of the reflected intensity profile to a well-known theoretical model, permitting the extraction of both absorption and reduced scattering coefficients of the tissue sample. Models and measurements of the endoscopic imaging system are presented in tissue phantoms and in vivo mouse colon, verifying the endoscope's capabilities to accurately measure effective attenuation coefficient and differentiate diseased from normal colon.

  8. Early outcomes of endoscopic transsphenoidal surgery for adult craniopharyngiomas.

    PubMed

    Jane, John A; Kiehna, Erin; Payne, Spencer C; Early, Stephen V; Laws, Edward R

    2010-04-01

    Although the transsphenoidal approach for subdiaphragmatic craniopharyngiomas has been performed for many years, there are few reports describing the role of the endoscopic transsphenoidal technique for suprasellar craniopharyngiomas. The purpose of this study was to report the outcomes of the endoscopic transsphenoidal approach for adults with craniopharyngiomas in whom the goal was gross-total resection. Twelve patients were identified who were older than 18 years at the time of their pure endoscopic transsphenoidal surgery. Their medical records and imaging studies were retrospectively reviewed. Gross-total resection was achieved in 42% of cases when assessed by intraoperative impression alone and in 75% when assessed by the first postoperative MR imaging study. However, 83% of patients achieved at least a 95% resection when assessed by both intraoperative impression and the first postoperative MR imaging study. Permanent diabetes insipidus occurred postoperatively in 44% of patients. Six (67%) of 9 patients who had a functioning hypothalamic-pituitary axis preoperatively developed panhypopituitarism after surgery. Visual improvement or normalization occurred in 78% of patients with preoperative visual deficits. Although no patient experienced a postoperative CSF leak, 1 patient was treated for meningitis. The authors have achieved a high rate of radical resection and symptomatic improvement with the endoscopic transsphenoidal technique for both subdiaphragmatic (sellar/suprasellar) and supradiaphragmatic (suprasellar) craniopharyngiomas. However, this is also associated with a high incidence of new endocrinopathy. Endoscopic assessment of tumor resection may be more sensitive for residual tumor than the first postoperative MR imaging study.

  9. Hypoxia Imaging Endoscopy Equipped with Laser Light Source from Preclinical Live Animal Study to First-In-Human Subject Research

    PubMed Central

    Kaneko, Kazuhiro; Yamaguchi, Hiroshi; Saito, Takaaki; Yano, Tomonori; Oono, Yasuhiro; Ikematsu, Hiroaki; Nomura, Shogo; Sato, Akihiro; Kojima, Motohiro; Esumi, Hiroyasu; Ochiai, Atsushi

    2014-01-01

    A goal in next-generation endoscopy is to develop functional imaging techniques to open up new opportunities for cancer diagnosis. Although spatial and temporal information on hypoxia is crucial for understanding cancer physiology and expected to be useful for cancer diagnosis, existing techniques using fluorescent indicators have limitations due to low spatial resolution and invasive administration. To overcome these problems, we developed an imaging technology based on hemoglobin oxygen saturation in both the tumor and surrounding mucosa using a laser endoscope system, and conducted the first human subject research for patients with aero-digestive tract cancer. The oxygen saturation map overlapped the images of cancerous lesions and indicated highly heterogeneous features of oxygen supply in the tumor. The hypoxic region of the tumor surface was found in both early cancer and cancer precursors. This technology illustrates a novel aspect of cancer biology as a potential biomarker and can be widely utilized in cancer diagnosis. PMID:24915532

  10. High-resolution handheld rigid endomicroscope based on full-field optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Benoit a la Guillaume, Emilie; Martins, Franck; Boccara, Claude; Harms, Fabrice

    2016-02-01

    Full-field optical coherence tomography (FF-OCT) is a powerful tool for nondestructive assessment of biological tissue, i.e., for the structural examination of tissue in depth at a cellular resolution. Mostly known as a microscopy device for ex vivo analysis, FF-OCT has also been adapted to endoscopy setups since it shows good potential for in situ cancer diagnosis and biopsy guidance. Nevertheless, all the attempts to perform endoscopic FF-OCT imaging did not go beyond lab setups. We describe here, to the best of our knowledge, the first handheld FF-OCT endoscope based on a tandem interferometry assembly using incoherent illumination. A common-path passive imaging interferometer at the tip of an optical probe makes it robust and insensitive to environmental perturbations, and a low finesse Fabry-Perot processing interferometer guarantees a compact system. A good resolution (2.7 μm transverse and 6 μm axial) is maintained through the long distance, small diameter relay optics of the probe, and a good signal-to-noise ratio is achieved in a limited 100 ms acquisition time. High-resolution images and a movie of a rat brain slice have been recorded by moving the contact endoscope over the surface of the sample, allowing for tissue microscopic exploration at 20 μm under the surface. These promising ex vivo results open new perspectives for in vivo imaging of biological tissue, in particular, in the field of cancer and surgical margin assessment.

  11. The experience of totally endoscopic coronary bypass grafting with the robotic system «Da Vinci» in Russia

    NASA Astrophysics Data System (ADS)

    Efendiev, V. U.; Alsov, S. A.; Ruzmatov, T. M.; Mikheenko, I. L.; Chernyavsky, A. M.; Malakhov, E. S.

    2015-11-01

    A new technology - a thoracoscopic coronary bypass grafting with the use of Da Vinci robotic system in Russia is represented by the experience of NRICP. The technology was introduced in Russia in 2011. Overall, one hundred endoscopic coronary artery bypass procedures were performed. We have compared and analyzed results of coronary artery stenting vs minimally invasive coronary artery bypass grafting. According to the results, totally endoscopic coronary artery bypass grafting has several advantages over alternative treatment strategies.

  12. A pilot trial of ambulatory monitoring of gastric motility using a modified magnetic capsule endoscope.

    PubMed

    Kim, Hee Man; Choi, Ja Sung; Cho, Jae Hee

    2014-04-30

    The magnetic capsule endoscope has been modified to be fixed inside the stomach and to monitor the gastric motility. This pilot trial was designed to investigate the feasibility of the magnetic capsule endoscope for monitoring gastric motility. The magnetic capsule endoscope was swallowed by the healthy volunteer and maneuvered by the external magnet on his abdomen surface inside the stomach. The magnetic capsule endoscope transmitted image of gastric peristalsis. This simple trial suggested that the real-time ambulatory monitoring of gastric motility should be feasible by using the magnetic capsule endoscope.

  13. Image-guided thoracic surgery in the hybrid operation room.

    PubMed

    Ujiie, Hideki; Effat, Andrew; Yasufuku, Kazuhiro

    2017-01-01

    There has been an increase in the use of image-guided technology to facilitate minimally invasive therapy. The next generation of minimally invasive therapy is focused on advancement and translation of novel image-guided technologies in therapeutic interventions, including surgery, interventional pulmonology, radiation therapy, and interventional laser therapy. To establish the efficacy of different minimally invasive therapies, we have developed a hybrid operating room, known as the guided therapeutics operating room (GTx OR) at the Toronto General Hospital. The GTx OR is equipped with multi-modality image-guidance systems, which features a dual source-dual energy computed tomography (CT) scanner, a robotic cone-beam CT (CBCT)/fluoroscopy, high-performance endobronchial ultrasound system, endoscopic surgery system, near-infrared (NIR) fluorescence imaging system, and navigation tracking systems. The novel multimodality image-guidance systems allow physicians to quickly, and accurately image patients while they are on the operating table. This yield improved outcomes since physicians are able to use image guidance during their procedures, and carry out innovative multi-modality therapeutics. Multiple preclinical translational studies pertaining to innovative minimally invasive technology is being developed in our guided therapeutics laboratory (GTx Lab). The GTx Lab is equipped with similar technology, and multimodality image-guidance systems as the GTx OR, and acts as an appropriate platform for translation of research into human clinical trials. Through the GTx Lab, we are able to perform basic research, such as the development of image-guided technologies, preclinical model testing, as well as preclinical imaging, and then translate that research into the GTx OR. This OR allows for the utilization of new technologies in cancer therapy, including molecular imaging, and other innovative imaging modalities, and therefore enables a better quality of life for patients, both during and after the procedure. In this article, we describe capabilities of the GTx systems, and discuss the first-in-human technologies used, and evaluated in GTx OR.

  14. Can masses of non-experts train highly accurate image classifiers? A crowdsourcing approach to instrument segmentation in laparoscopic images.

    PubMed

    Maier-Hein, Lena; Mersmann, Sven; Kondermann, Daniel; Bodenstedt, Sebastian; Sanchez, Alexandro; Stock, Christian; Kenngott, Hannes Gotz; Eisenmann, Mathias; Speidel, Stefanie

    2014-01-01

    Machine learning algorithms are gaining increasing interest in the context of computer-assisted interventions. One of the bottlenecks so far, however, has been the availability of training data, typically generated by medical experts with very limited resources. Crowdsourcing is a new trend that is based on outsourcing cognitive tasks to many anonymous untrained individuals from an online community. In this work, we investigate the potential of crowdsourcing for segmenting medical instruments in endoscopic image data. Our study suggests that (1) segmentations computed from annotations of multiple anonymous non-experts are comparable to those made by medical experts and (2) training data generated by the crowd is of the same quality as that annotated by medical experts. Given the speed of annotation, scalability and low costs, this implies that the scientific community might no longer need to rely on experts to generate reference or training data for certain applications. To trigger further research in endoscopic image processing, the data used in this study will be made publicly available.

  15. Novel, high-definition 3-D endoscopy system with real-time compression communication system to aid diagnoses and treatment between hospitals in Thailand.

    PubMed

    Uemura, Munenori; Kenmotsu, Hajime; Tomikawa, Morimasa; Kumashiro, Ryuichi; Yamashita, Makoto; Ikeda, Testuo; Yamashita, Hiromasa; Chiba, Toshio; Hayashi, Koichi; Sakae, Eiji; Eguchi, Mitsuo; Fukuyo, Tsuneo; Chittmittrapap, Soottiporn; Navicharern, Patpong; Chotiwan, Pornarong; Pattana-Arum, Jirawat; Hashizume, Makoto

    2015-05-01

    Traditionally, laparoscopy has been based on 2-D imaging, which represents a considerable challenge. As a result, 3-D visualization technology has been proposed as a way to better facilitate laparoscopy. We compared the latest 3-D systems with high-end 2-D monitors to validate the usefulness of new systems for endoscopic diagnoses and treatment in Thailand. We compared the abilities of our high-definition 3-D endoscopy system with real-time compression communication system with a conventional high-definition (2-D) endoscopy system by asking health-care staff to complete tasks. Participants answered questionnaires and whether procedures were easier using our system or the 2-D endoscopy system. Participants were significantly faster at suture insertion with our system (34.44 ± 15.91 s) than with the 2-D system (52.56 ± 37.51 s) (P < 0.01). Most surgeons thought that the 3-D system was good in terms of contrast, brightness, perception of the anteroposterior position of the needle, needle grasping, inserting the needle as planned, and needle adjustment during laparoscopic surgery. Several surgeons highlighted the usefulness of exposing and clipping the bile duct and gallbladder artery, as well as dissection from the liver bed during laparoscopic surgery. In an image-transfer experiment with RePure-L®, participants at Rajavithi Hospital could obtain reconstructed 3-D images that were non-inferior to conventional images from Chulalongkorn University Hospital (10 km away). These data suggest that our newly developed system could be of considerable benefit to the health-care system in Thailand. Transmission of moving endoscopic images from a center of excellence to a rural hospital could help in the diagnosis and treatment of various diseases. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  16. Tethered SECM endoscopic capsule for the diagnosis of eosinophilic esophagitis (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Do, Dukho; Kang, DongKyun; Tabatabaei, Nima; Grant, Catriona N.; Nishioka, Norman S.; Rosenberg, Mireille; Hesterberg, Paul E.; Yuan, Qian; Garber, John J.; Katz, Aubrey J.; Shreffler, Wayne G.; Tearney, Guillermo J.

    2017-02-01

    Eosinophilic Esophagitis (EoE) is an inflammatory disease caused by inhaled or ingested food allergies, and characterized by the infiltration of eosinophils in the esophagus. The gold standard for diagnosing EoE is to conduct endoscopy and obtain multiple biopsy specimens from different portions of the esophagus; an exam is considered positive if more than 15 eosinophils per high power field (HPF) in any of the biopsies. This method of diagnosis is problematic because endoscopic biopsy is expensive and poorly tolerated and the esophageal eosinophil burden needs to be monitored frequently during the course of the disease. Spectrally encoded confocal microscopy (SECM) is a high-speed confocal microscopy technology that can visualize individual eosinophils in large microscopic images of the human esophagus, equivalent to more than 30,000 HPF. Previously, we have demonstrated that tethered capsule SECM can be conducted in unsedated subjects with diagnosed EoE. However, speckle noise and the relatively low resolution in images obtained with the first capsule prototypes made it challenging to distinguish eosinophils from other cells. In this work, we present a next-generation tethered SECM capsule, which has been modified to significantly improve image quality. First, we substituted the single mode fiber with a dual-clad fiber to reduce speckle noise. A gradient-index multimode fiber was fusion spliced at the tip of the dual-clad fiber to increase the effective numerical aperture of the fiber from 0.09 to 0.15, expanding the beam more rapidly to increase the illumination aperture at the objective. These modifications enabled the new SECM capsule to achieve a lateral resolution of 1.8 µm and an axial resolution of 16.1 µm, which substantially improves the capacity of this probe to visualize cellular features in human tissue. The total size of the SECM capsule remained 6.75 mm in diameter and 31 mm in length. We are now in the process of testing this new SECM capsule in humans. Early results using this new SECM capsule suggest that this technology has the potential to be an effective tool for the diagnosis of EoE.

  17. LC-lens array with light field algorithm for 3D biomedical applications

    NASA Astrophysics Data System (ADS)

    Huang, Yi-Pai; Hsieh, Po-Yuan; Hassanfiroozi, Amir; Martinez, Manuel; Javidi, Bahram; Chu, Chao-Yu; Hsuan, Yun; Chu, Wen-Chun

    2016-03-01

    In this paper, liquid crystal lens (LC-lens) array was utilized in 3D bio-medical applications including 3D endoscope and light field microscope. Comparing with conventional plastic lens array, which was usually placed in 3D endoscope or light field microscope system to record image disparity, our LC-lens array has higher flexibility of electrically changing its focal length. By using LC-lens array, the working distance and image quality of 3D endoscope and microscope could be enhanced. Furthermore, the 2D/3D switching ability could be achieved if we turn off/on the electrical power on LClens array. In 3D endoscope case, a hexagonal micro LC-lens array with 350um diameter was placed at the front end of a 1mm diameter endoscope. With applying electric field on LC-lens array, the 3D specimen would be recorded as from seven micro-cameras with different disparity. We could calculate 3D construction of specimen with those micro images. In the other hand, if we turn off the electric field on LC-lens array, the conventional high resolution 2D endoscope image would be recorded. In light field microscope case, the LC-lens array was placed in front of the CMOS sensor. The main purpose of LC-lens array is to extend the refocusing distance of light field microscope, which is usually very narrow in focused light field microscope system, by montaging many light field images sequentially focusing on different depth. With adjusting focal length of LC-lens array from 2.4mm to 2.9mm, the refocusing distance was extended from 1mm to 11.3mm. Moreover, we could use a LC wedge to electrically shift the optics axis and increase the resolution of light field.

  18. Endoscopic transnasal odontoidectomy combined with posterior reduction to treat basilar invagination: technical note.

    PubMed

    Yu, Yong; Hu, Fan; Zhang, Xiaobiao; Ge, Junqi; Sun, Chongjing

    2013-11-01

    Transoral microscopic odontoidectomy has been accepted as a standard procedure to treat basilar invagination over the past several decades. In recent years the emergence of new technologies, including endoscopic odontoidectomy and posterior reduction, has presented a challenge to the traditional treatment algorithm. In this article, the authors describe 1 patient with basilar invagination who was successfully treated with endoscopic transnasal odontoidectomy combined with posterior reduction. The purpose of this report is to validate the effectiveness of this treatment algorithm in selected cases and describe several operative nuances and pearls based on the authors' experience. One patient with basilar invagination caused by a congenital osseous malformation underwent endoscopic transnasal odontoidectomy combined with posterior reduction in a single operative setting. The purely endoscopic transnasal odontoidectomy was first conducted with the patient supine. The favorable anatomical reduction was then achieved through a posterior approach after the patient was moved prone. The patient was extubated after recovery from anesthesia and allowed oral food intake the next day. No complications were noted, and the patient was discharged 4 days after the operation. Postoperative imaging demonstrated excellent decompression of the anterior cervicomedullary junction pathology. The patient was followed up for 12 months and remarkable neurological recovery was observed. The endoscopic transnasal odontoidectomy is a better minimally invasive approach for anterior decompression and can make the posterior reduction easier because the anterior resistant force is eliminated. The subsequent posterior reduction can make decompression of the ventral side of the cervicomedullary junction more effective because the C-2 vertebral body is pushed forward. A combination of these 2 approaches has the advantages of minimally invasive access and a faster patient recovery, and thus is a valid alternative in selected cases.

  19. Techniques of imaging of the aorta and its first order branches by endoscopic ultrasound (with videos)

    PubMed Central

    Sharma, Malay; Rai, Praveer; Mehta, Varun; Rameshbabu, C. S.

    2015-01-01

    Endoscopic ultrasonography (EUS) is a useful modality for imaging of the blood vessels of the mediastinum and abdomen. The aorta acts as an important home base during EUS imaging. The aorta and its branches are accessible by standard angiographic methods, but endosonography also provides a unique opportunity to evaluate the aorta and its branches. This article describes the techniques of imaging of different part of the aorta by EUS. PMID:26020043

  20. Renal surgery in the new millennium.

    PubMed

    Delvecchio, F C; Preminger, G M

    2000-11-01

    In the not too distant future, the minimally invasive renal surgeon will be able to practice an operation on a difficult case on a three-dimensional virtual reality simulator, providing all attributes of the real procedure. The patient's imaging studies will be imported into the simulator to better mimic particular anatomy. When confident enough of his or her skills, the surgeon will start operating on the patient using the same virtual reality simulator/telepresence surgery console system, which will permit the live surgery to be conducted by robots hundreds of miles away. The robots will manipulate miniature endoscopes or control minimally or noninvasive ablative technologies. Endoscopic/laparoscopic footage of the surgical procedure will be stored digitally in optical disks to be used later in telementoring of a surgery resident. All this and more will be possible in the not so distant third millennium.

  1. Hyperspectral imaging fluorescence excitation scanning for detecting colorectal cancer: pilot study

    NASA Astrophysics Data System (ADS)

    Leavesley, Silas J.; Wheeler, Mikayla; Lopez, Carmen; Baker, Thomas; Favreau, Peter F.; Rich, Thomas C.; Rider, Paul F.; Boudreaux, Carole W.

    2016-03-01

    Optical spectroscopy and hyperspectral imaging have shown the theoretical potential to discriminate between cancerous and non-cancerous tissue with high sensitivity and specificity. To date, these techniques have not been able to be effectively translated to endoscope platforms. Hyperspectral imaging of the fluorescence excitation spectrum represents a new technology that may be well-suited for endoscopic implementation. However, the feasibility of detecting differences between normal and cancerous mucosa using fluorescence excitation-scanning hyperspectral imaging has not been evaluated. The objective of this pilot study was to evaluate the changes in the fluorescence excitation spectrum of resected specimen pairs of colorectal adenocarcinoma and normal colorectal mucosa. Patients being treated for colorectal adenocarcinoma were enrolled. Representative adenocarcinoma and normal colonic mucosa specimens were collected from each case. Specimens were flash frozen in liquid nitrogen. Adenocarcinoma was confirmed by histologic evaluation of H&E permanent sections. Hyperspectral image data of the fluorescence excitation of adenocarcinoma and surrounding normal tissue were acquired using a custom microscope configuration previously developed in our lab. Results demonstrated consistent spectral differences between normal and cancerous tissues over the fluorescence excitation spectral range of 390-450 nm. We conclude that fluorescence excitation-scanning hyperspectral imaging may offer an alternative approach for differentiating adenocarcinoma and surrounding normal mucosa of the colon. Future work will focus on expanding the number of specimen pairs analyzed and will utilize fresh tissues where possible, as flash freezing and reconstituting tissues may have altered the autofluorescence properties.

  2. Clinically compatible flexible wide-field multi-color fluorescence endoscopy with a porcine colon model

    PubMed Central

    Oh, Gyugnseok; Park, Youngrong; Yoo, Su Woong; Hwang, Soonjoo; Chin-Yu, Alexey V. Dan; Ryu, Yeon-Mi; Kim, Sang-Yeob; Do, Eun-Ju; Kim, Ki Hean; Kim, Sungjee; Myung, Seung-Jae; Chung, Euiheon

    2017-01-01

    Early detection of structural or molecular changes in dysplastic epithelial tissues is crucial for cancer screening and surveillance. Multi-targeting molecular endoscopic fluorescence imaging may improve noninvasive detection of precancerous lesions in the colon. Here, we report the first clinically compatible, wide-field-of-view, multi-color fluorescence endoscopy with a leached fiber bundle scope using a porcine model. A porcine colon model that resembles the human colon is used for the detection of surrogate tumors composed of multiple biocompatible fluorophores (FITC, ICG, and heavy metal-free quantum dots (hfQDs)). With an ex vivo porcine colon tumor model, molecular imaging with hfQDs conjugated with MMP14 antibody was achieved by spraying molecular probes on a mucosa layer that contains xenograft tumors. With an in vivo porcine colon embedded with surrogate tumors, target-to-background ratios of 3.36 ± 0.43, 2.70 ± 0.72, and 2.10 ± 0.13 were achieved for FITC, ICG, and hfQD probes, respectively. This promising endoscopic technology with molecular contrast shows the capacity to reveal hidden tumors and guide treatment strategy decisions. PMID:28270983

  3. Integrated Raman spectroscopy and trimodal wide-field imaging techniques for real-time in vivo tissue Raman measurements at endoscopy.

    PubMed

    Huang, Zhiwei; Teh, Seng Khoon; Zheng, Wei; Mo, Jianhua; Lin, Kan; Shao, Xiaozhuo; Ho, Khek Yu; Teh, Ming; Yeoh, Khay Guan

    2009-03-15

    We report an integrated Raman spectroscopy and trimodal (white-light reflectance, autofluorescence, and narrow-band) imaging techniques for real-time in vivo tissue Raman measurements at endoscopy. A special 1.8 mm endoscopic Raman probe with filtering modules is developed, permitting effective elimination of interference of fluorescence background and silica Raman in fibers while maximizing tissue Raman collections. We demonstrate that high-quality in vivo Raman spectra of upper gastrointestinal tract can be acquired within 1 s or subseconds under the guidance of wide-field endoscopic imaging modalities, greatly facilitating the adoption of Raman spectroscopy into clinical research and practice during routine endoscopic inspections.

  4. Endoscopic ultrasound: state-of-the-art GI tumor staging

    NASA Astrophysics Data System (ADS)

    Trowers, Eugene A.

    1999-06-01

    Videoendoscopy has truly enlarged the scope of diagnostic and therapeutic gastroenterology. However, videoendoscopic examinations are limited to the mucosal surface. Endoscopic ultrasound allows the endoscopist a view beyond the intestinal wall which opens the door to a variety of new gastroenterologic techniques. The evaluation of plain images in combination with contrast-enhanced imags has been found to be helpful when applied to CT and MRI. A similar advantage may be found for endoscopic ultrasound (EUS) studies. The efficacy of EUS with and without contrast enhancement is critically reviewed.

  5. Tuberculosis and the pancreas: a diagnostic challenge solved by endoscopic ultrasound. A case series.

    PubMed

    Chatterjee, Suvadip; Schmid, Matthias L; Anderson, Kirsty; Oppong, Kofi W

    2012-03-01

    Pancreatic tuberculosis is a rare disease. It can be easily confused with malignancy or pancreatitis on imaging. This could result in unnecessary surgery. As this is a treatable disease it is imperative to diagnose this condition pre-operatively. We report three cases of pancreatic tuberculosis that were diagnosed by endoscopic ultrasound. In conclusion, endoscopic ultrasound is the diagnostic modality of choice for pancreatic tuberculosis facilitating high resolution imaging, as well as sampling of tissue for staining, cytology, culture and polymerase chain reaction assay.

  6. An automatic detection method for the boiler pipe header based on real-time image acquisition

    NASA Astrophysics Data System (ADS)

    Long, Yi; Liu, YunLong; Qin, Yongliang; Yang, XiangWei; Li, DengKe; Shen, DingJie

    2017-06-01

    Generally, an endoscope is used to test the inner part of the thermal power plants boiler pipe header. However, since the endoscope hose manual operation, the length and angle of the inserted probe cannot be controlled. Additionally, it has a big blind spot observation subject to the length of the endoscope wire. To solve these problems, an automatic detection method for the boiler pipe header based on real-time image acquisition and simulation comparison techniques was proposed. The magnetic crawler with permanent magnet wheel could carry the real-time image acquisition device to complete the crawling work and collect the real-time scene image. According to the obtained location by using the positioning auxiliary device, the position of the real-time detection image in a virtual 3-D model was calibrated. Through comparing of the real-time detection images and the computer simulation images, the defects or foreign matter fall into could be accurately positioning, so as to repair and clean up conveniently.

  7. A videoscope for use in minimally invasive periodontal surgery.

    PubMed

    Harrel, Stephen K; Wilson, Thomas G; Rivera-Hidalgo, Francisco

    2013-09-01

    Minimally invasive periodontal procedures have been reported to produce excellent clinical results. Visualization during minimally invasive procedures has traditionally been obtained by the use of surgical telescopes, surgical microscopes, glass fibre endoscopes or a combination of these devices. All of these methods for visualization are less than fully satisfactory due to problems with access, magnification and blurred imaging. A videoscope for use with minimally invasive periodontal procedures has been developed to overcome some of the difficulties that exist with current visualization approaches. This videoscope incorporates a gas shielding technology that eliminates the problems of fogging and fouling of the optics of the videoscope that has previously prevented the successful application of endoscopic visualization to periodontal surgery. In addition, as part of the gas shielding technology the videoscope also includes a moveable retractor specifically adapted for minimally invasive surgery. The clinical use of the videoscope during minimally invasive periodontal surgery is demonstrated and discussed. The videoscope with gas shielding alleviates many of the difficulties associated with visualization during minimally invasive periodontal surgery. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. In vivo imaging in the oral cavity by endoscopic optical coherence tomography.

    PubMed

    Walther, Julia; Schnabel, Christian; Tetschke, Florian; Rosenauer, Tobias; Golde, Jonas; Ebert, Nadja; Baumann, Michael; Hannig, Christian; Koch, Edmund

    2018-03-01

    The common way to diagnose hard and soft tissue irregularities in the oral cavity is initially the visual inspection by an experienced dentist followed by further medical examinations, such as radiological imaging and/or histopathological investigation. For the diagnosis of oral hard and soft tissues, the detection of early transformations is mostly hampered by poor visual access, low specificity of the diagnosis techniques, and/or limited feasibility of frequent screenings. Therefore, optical noninvasive diagnosis of oral tissue is promising to improve the accuracy of oral screening. Considering this demand, a rigid handheld endoscopic scanner was developed for optical coherence tomography (OCT). The novelty is the usage of a commercially near-infrared endoscope with fitting optics in combination with an established spectral-domain OCT system of our workgroup. By reaching a high spatial resolution, in vivo images of anterior and especially posterior dental and mucosal tissues were obtained from the oral cavity of two volunteers. The convincing image quality of the endoscopic OCT device is particularly obvious for the imaging of different regions of the human soft palate with highly scattering fibrous layer and capillary network within the lamina propria. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  9. Catheter-based photoacoustic endoscope

    PubMed Central

    Yang, Joon-Mo; Li, Chiye; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2014-01-01

    Abstract. We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique’s benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument’s flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system. PMID:24887743

  10. Advances in engineering of high contrast CARS imaging endoscopes

    PubMed Central

    Deladurantaye, Pascal; Paquet, Alex; Paré, Claude; Zheng, Huimin; Doucet, Michel; Gay, David; Poirier, Michel; Cormier, Jean-François; Mermut, Ozzy; Wilson, Brian C.; Seibel, Eric J.

    2014-01-01

    The translation of CARS imaging towards real time, high resolution, chemically selective endoscopic tissue imaging applications is limited by a lack of sensitivity in CARS scanning probes sufficiently small for incorporation into endoscopes. We have developed here a custom double clad fiber (DCF)-based CARS probe which is designed to suppress the contaminant Four-Wave-Mixing (FWM) background generated within the fiber and integrated it into a fiber based scanning probe head of a few millimeters in diameter. The DCF includes a large mode area (LMA) core as a first means of reducing FWM generation by ~3 dB compared to commercially available, step-index single mode fibers. A micro-fabricated miniature optical filter (MOF) was grown on the distal end of the DCF to block the remaining FWM background from reaching the sample. The resulting probe was used to demonstrate high contrast images of polystyrene beads in the forward-CARS configuration with > 10 dB suppression of the FWM background. In epi-CARS geometry, images exhibited lower contrast due to the leakage of MOF-reflected FWM from the fiber core. Improvements concepts for the fiber probe are proposed for high contrast epi-CARS imaging to enable endoscopic implementation in clinical tissue assessment contexts, particularly in the early detection of endoluminal cancers and in tumor margin assessment. PMID:25401538

  11. Connection method of separated luminal regions of intestine from CT volumes

    NASA Astrophysics Data System (ADS)

    Oda, Masahiro; Kitasaka, Takayuki; Furukawa, Kazuhiro; Watanabe, Osamu; Ando, Takafumi; Hirooka, Yoshiki; Goto, Hidemi; Mori, Kensaku

    2015-03-01

    This paper proposes a connection method of separated luminal regions of the intestine for Crohn's disease diagnosis. Crohn's disease is an inflammatory disease of the digestive tract. Capsule or conventional endoscopic diagnosis is performed for Crohn's disease diagnosis. However, parts of the intestines may not be observed in the endoscopic diagnosis if intestinal stenosis occurs. Endoscopes cannot pass through the stenosed parts. CT image-based diagnosis is developed as an alternative choice of the Crohn's disease. CT image-based diagnosis enables physicians to observe the entire intestines even if stenosed parts exist. CAD systems for Crohn's disease using CT volumes are recently developed. Such CAD systems need to reconstruct separated luminal regions of the intestines to analyze intestines. We propose a connection method of separated luminal regions of the intestines segmented from CT volumes. The luminal regions of the intestines are segmented from a CT volume. The centerlines of the luminal regions are calculated by using a thinning process. We enumerate all the possible sequences of the centerline segments. In this work, we newly introduce a condition using distance between connected ends points of the centerline segments. This condition eliminates unnatural connections of the centerline segments. Also, this condition reduces processing time. After generating a sequence list of the centerline segments, the correct sequence is obtained by using an evaluation function. We connect the luminal regions based on the correct sequence. Our experiments using four CT volumes showed that our method connected 6.5 out of 8.0 centerline segments per case. Processing times of the proposed method were reduced from the previous method.

  12. Endoscopic high-resolution auto fluorescence imaging and optical coherence tomography of airways in vivo (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Pahlevaninezhad, Hamid; Lee, Anthony; Hohert, Geoffrey; Schwartz, Carley; Shaipanich, Tawimas; Ritchie, Alexander J.; Zhang, Wei; MacAulay, Calum E.; Lam, Stephen; Lane, Pierre M.

    2016-03-01

    In this work, we present multimodal imaging of peripheral airways in vivo using an endoscopic imaging system capable of co-registered optical coherence tomography and autofluorescence imaging (OCT-AFI). This system employs a 0.9 mm diameter double-clad fiber optic-based catheter for endoscopic imaging of small peripheral airways. Optical coherence tomography (OCT) can visualize detailed airway morphology in the lung periphery and autofluorescence imaging (AFI) can visualize fluorescent tissue components such as collagen and elastin, improving the detection of airway lesions. Results from in vivo imaging of 40 patients indicate that OCT and AFI offer complementary information that may increase the ability to identify pulmonary nodules in the lung periphery and improve the safety of biopsy collection by identifying large blood vessels. AFI can rapidly visualize in vivo vascular networks using fast scanning parameters resulting in vascular-sensitive imaging with less breathing/cardiac motion artifacts compared to Doppler OCT imaging. By providing complementary information about structure and function of tissue, OCT-AFI may improve site selection during biopsy collection in the lung periphery.

  13. High resolution axicon-based endoscopic FD OCT imaging with a large depth range

    NASA Astrophysics Data System (ADS)

    Lee, Kye-Sung; Hurley, William; Deegan, John; Dean, Scott; Rolland, Jannick P.

    2010-02-01

    Endoscopic imaging in tubular structures, such as the tracheobronchial tree, could benefit from imaging optics with an extended depth of focus (DOF). This optics could accommodate for varying sizes of tubular structures across patients and along the tree within a single patient. In the paper, we demonstrate an extended DOF without sacrificing resolution showing rotational images in biological tubular samples with 2.5 μm axial resolution, 10 ìm lateral resolution, and > 4 mm depth range using a custom designed probe.

  14. SU-C-18A-02: Image-Based Camera Tracking: Towards Registration of Endoscopic Video to CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, S; Rao, A; Wendt, R

    Purpose: Endoscopic examinations are routinely performed on head and neck and esophageal cancer patients. However, these images are underutilized for radiation therapy because there is currently no way to register them to a CT of the patient. The purpose of this work is to develop a method to track the motion of an endoscope within a structure using images from standard clinical equipment. This method will be incorporated into a broader endoscopy/CT registration framework. Methods: We developed a software algorithm to track the motion of an endoscope within an arbitrary structure. We computed frame-to-frame rotation and translation of the cameramore » by tracking surface points across the video sequence and utilizing two-camera epipolar geometry. The resulting 3D camera path was used to recover the surrounding structure via triangulation methods. We tested this algorithm on a rigid cylindrical phantom with a pattern spray-painted on the inside. We did not constrain the motion of the endoscope while recording, and we did not constrain our measurements using the known structure of the phantom. Results: Our software algorithm can successfully track the general motion of the endoscope as it moves through the phantom. However, our preliminary data do not show a high degree of accuracy in the triangulation of 3D point locations. More rigorous data will be presented at the annual meeting. Conclusion: Image-based camera tracking is a promising method for endoscopy/CT image registration, and it requires only standard clinical equipment. It is one of two major components needed to achieve endoscopy/CT registration, the second of which is tying the camera path to absolute patient geometry. In addition to this second component, future work will focus on validating our camera tracking algorithm in the presence of clinical imaging features such as patient motion, erratic camera motion, and dynamic scene illumination.« less

  15. A video-based speed estimation technique for localizing the wireless capsule endoscope inside gastrointestinal tract.

    PubMed

    Bao, Guanqun; Mi, Liang; Geng, Yishuang; Zhou, Mingda; Pahlavan, Kaveh

    2014-01-01

    Wireless Capsule Endoscopy (WCE) is progressively emerging as one of the most popular non-invasive imaging tools for gastrointestinal (GI) tract inspection. As a critical component of capsule endoscopic examination, physicians need to know the precise position of the endoscopic capsule in order to identify the position of intestinal disease. For the WCE, the position of the capsule is defined as the linear distance it is away from certain fixed anatomical landmarks. In order to measure the distance the capsule has traveled, a precise knowledge of how fast the capsule moves is urgently needed. In this paper, we present a novel computer vision based speed estimation technique that is able to extract the speed of the endoscopic capsule by analyzing the displacements between consecutive frames. The proposed approach is validated using a virtual testbed as well as the real endoscopic images. Results show that the proposed method is able to precisely estimate the speed of the endoscopic capsule with 93% accuracy on average, which enhances the localization accuracy of the WCE to less than 2.49 cm.

  16. Endoscopic Optical Coherence Tomography

    NASA Astrophysics Data System (ADS)

    Zhou, Chao; Fujimoto, James G.; Tsai, Tsung-Han; Mashimo, Hiroshi

    New gastrointestinal (GI) cancers are expected to affect more than 290,200 new patients and will cause more than 144,570 deaths in the United States in 2013 [1]. When detected and treated early, the 5-year survival rate for colorectal cancer increases by a factor of 1.4 [1]. For esophageal cancer, the rate increases by a factor of 2 [1]. The majority of GI cancers begin as small lesions that are difficult to identify with conventional endoscopy. With resolutions approaching that of histopathology, optical coherence tomography (OCT) is well suited for detecting the changes in tissue microstructure associated with early GI cancers. Since the lesions are not endoscopically apparent, however, it is necessary to survey a relatively large area of the GI tract. Tissue motion is another limiting factor in the GI tract; therefore, in vivo imaging must be performed at extremely high speeds. OCT imaging can be performed using fiber optics and miniaturized lens systems, enabling endoscopic OCT inside the human body in conjunction with conventional video endoscopy. An OCT probe can be inserted through the working channel of a standard endoscope, thus enabling depth-resolved imaging of tissue microstructure in the GI tract with micron-scale resolution simultaneously with the endoscopic view (Fig. 68.1).

  17. [The operating room of the future].

    PubMed

    Broeders, I A; Niessen, W; van der Werken, C; van Vroonhoven, T J

    2000-01-29

    Advances in computer technology will revolutionize surgical techniques in the next decade. The operating room (OR) of the future will be connected with a laboratory where clinical specialists and researchers prepare image-guided interventions and explore the possibilities of these techniques. The virtual reality is linked to the actual situation in the OR with the aid of navigation instruments. During complicated operations the images prepared preoperatively will be corrected during the operation on the basis of the information obtained peroperatively. MRI currently offers maximal possibilities for image-guided surgery of soft tissues. Simpler techniques such as fluoroscopy and echography will become increasingly integrated in computer-assisted peroperative navigation. The development of medical robot systems will make possible microsurgical procedures by the endoscopic route. Tele-manipulation systems will also play a part in the training of surgeons. Design and construction of the OR will be adapted to the surgical technology, and include an information and control unit where preoperative and peroperative data come together and from where the surgeon operates the instruments. Concepts for the future OR should be regularly adjusted to allow for new surgical technology.

  18. Current trends and pitfalls in endoscopic treatment of urolithiasis.

    PubMed

    Inoue, Takaaki; Okada, Shinsuke; Hamamoto, Shuzo; Yoshida, Takashi; Matsuda, Tadashi

    2018-02-01

    Current development of endoscopic technology, lithotripters, and stone-retrieval devices has expanded the indications for retrograde and antegrade endoscopic therapy in the management of urolithiasis. This technology has also resulted in minimally invasive therapy. As surgeons' experience of endourological procedures with the newer instruments has become integrated, the surgical technique and indications for urolithiasis have also changed in the past few years. The present review provides an overview of endourological procedures for upper urinary tract stones and the key points related to surgical techniques. © 2017 The Japanese Urological Association.

  19. Autofluorescence endoscopy with "real-time" digital image processing in differential diagnostics of selected benign and malignant lesions in the oesophagus.

    PubMed

    Sieroń-Stołtny, Karolina; Kwiatek, Sebastian; Latos, Wojciech; Kawczyk-Krupka, Aleksandra; Cieślar, Grzegorz; Stanek, Agata; Ziaja, Damian; Bugaj, Andrzej M; Sieroń, Aleksander

    2012-03-01

    Oesophageal papilloma and Barrett's oesophagus are benign lesions known as risk factors of carcinoma in the oesophagus. Therefore, it is important to diagnose these early changes before neoplastic transformation. Autofluorescence endoscopy is a fast and non-invasive method of imaging of tissues based on the natural fluorescence of endogenous fluorophores. The aim of this study was to prove the diagnostic utility of autofluorescence endoscopy with digital image processing in histological diagnosis of endoscopic findings in the upper digestive tract, primarily in the imaging of oesophageal papilloma. During the retrospective analysis of about 200 endoscopic procedures in the upper digestive tract, 67 cases of benign, precancerous or cancerous changes were found. White light endoscopy (WLE) image, single-channel (red or green) autofluorescence images, as well as green and red fluorescence intensities in two modal fluorescence image and red-to-green (R/G) ratio (Numerical Colour Value, NCV) were correlated with histopathologic results. The NCV analysis in autofluorescence imaging (AFI) showed increased R/G ratio in cancerous changes in 96% vs. 85% in WLE. Simultaneous analysis with digital image processing allowed us to diagnose suspicious tissue as cancerous in all of cases. Barrett's metaplasia was confirmed in 90% vs. 79% (AFI vs. WLE), and 98% in imaging with digital image processing. In benign lesions, WLE allowed us to exclude tissue as malignant in 85%. Using autofluorescence endoscopy R/G ratio was increased in only 10% of benign changes causing the picture to be interpreted as suspicious, but when both methods were used together, 97.5% were cases excluded as malignancies. Mean R/G ratios were estimated to be 2.5 in cancers, 1.25 in Barrett's metaplasia and 0.75 in benign changes and were statistically significant (p=0.04). Autofluorescence imaging is a sensitive method to diagnose precancerous and cancerous early stages of the diseases located in oesophagus. Especially in two-modal imaging including white light endoscopy, autofluorescence imaging with digital image processing seems to be a useful modality of early diagnostics. Also in observation of papilloma changes, it facilitates differentiation between neoplastic and benign lesions and more accurate estimation of the risk of potential malignancy. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Fully wireless pressure sensor based on endoscopy images

    NASA Astrophysics Data System (ADS)

    Maeda, Yusaku; Mori, Hirohito; Nakagawa, Tomoaki; Takao, Hidekuni

    2018-04-01

    In this paper, the result of developing a fully wireless pressure sensor based on endoscopy images for an endoscopic surgery is reported for the first time. The sensor device has structural color with a nm-scale narrow gap, and the gap is changed by air pressure. The structural color of the sensor is acquired from camera images. Pressure detection can be realized with existing endoscope configurations only. The inner air pressure of the human body should be measured under flexible-endoscope operation using the sensor. Air pressure monitoring, has two important purposes. The first is to quantitatively measure tumor size under a constant air pressure for treatment selection. The second purpose is to prevent the endangerment of a patient due to over transmission of air. The developed sensor was evaluated, and the detection principle based on only endoscopy images has been successfully demonstrated.

  1. Targeted detection of murine colonic dysplasia in vivo with flexible multispectral scanning fiber endoscopy

    NASA Astrophysics Data System (ADS)

    Joshi, Bishnu P.; Miller, Sharon J.; Lee, Cameron; Gustad, Adam; Seibel, Eric J.; Wang, Thomas D.

    2012-02-01

    We demonstrate a multi-spectral scanning fiber endoscope (SFE) that collects fluorescence images in vivo from three target peptides that bind specifically to murine colonic adenomas. This ultrathin endoscope was demonstrated in a genetically engineered mouse model of spontaneous colorectal adenomas based on somatic Apc (adenomatous polyposis coli) gene inactivation. The SFE delivers excitation at 440, 532, 635 nm with <2 mW per channel. The target 7-mer peptides were conjugated to visible organic dyes, including 7-Diethylaminocoumarin-3-carboxylic acid (DEAC) (λex=432 nm, λem=472 nm), 5-Carboxytetramethylrhodamine (5-TAMRA) (λex=535 nm, λem=568 nm), and CF-633 (λex=633 nm, λem=650 nm). Target peptides were first validated using techniques of pfu counting, flow cytometry and previously established methods of fluorescence endoscopy. Peptides were applied individually or in combination and detected with fluorescence imaging. The ability to image multiple channels of fluorescence concurrently was successful for all three channels in vitro, while two channels were resolved simultaneously in vivo. Selective binding of the peptide was evident to adenomas and not to adjacent normal-appearing mucosa. Multispectral wide-field fluorescence detection using the SFE is achievable, and this technology has potential to advance early cancer detection and image-guided therapy in human patients by simultaneously visualizing multiple over expressed molecular targets unique to dysplasia.

  2. Patterning of Spiral Structure on Optical Fiber by Focused-Ion-Beam Etching

    NASA Astrophysics Data System (ADS)

    Mekaru, Harutaka; Yano, Takayuki

    2012-06-01

    We produce patterns on minute and curved surfaces of optical fibers, and develop a processing technology for fabricating sensors, antennas, electrical circuits, and other devices on such patterned surfaces by metallization. A three-dimensional processing technology can be used to fabricate a spiral coil on the surface of cylindrical quartz materials, and then the microcoils can also be applied to capillaries of micro-fluid devices, as well as to receiver coils connected to a catheter and an endoscope of nuclear magnetic resonance imaging (MRI) systems used in imaging blood vessels. To create a spiral line pattern with a small linewidth on a full-circumference surface of an optical fiber, focused-ion-beam (FIB) etching was employed. Here, a simple rotation stage comprising a dc motor and an LR3 battery was built. However, during the development of a prototype rotation stage before finalizing a large-scale remodelling of our FIB etching system, a technical problem was encountered where a spiral line could not be processed without running into breaks and notches in the features. It turned out that the problem was caused by axis blur resulting from an eccentric spinning (or wobbling) of the axis of the fiber caused by its unrestrained free end. The problem was solved by installing a rotation guide and an axis suppression device onto the rotation stage. Using this improved rotation stage. we succeeded in the seamless patterning of 1-µm-wide features on the full-circumference surface of a 250-µm-diameter quartz optical fiber (QOF) by FIB etching.

  3. Disinfection of Cystoscopes by Subatmospheric Steam and Steam and Formaldehyde at 80°C

    PubMed Central

    Alder, V. G.; Gingell, J. C.; Mitchell, J. P.

    1971-01-01

    A new method of disinfection adapted for endoscopic instruments uses low temperature steam at 80°C or steam and formaldehyde at 80°C. The process has considerable advantages over existing methods and more closely approaches the ideal requirements. ImagesFIG. 3FIG. 4FIG. 5 PMID:5569551

  4. Imaging pancreatobiliary ductal system with optical coherence tomography: A review

    PubMed Central

    Mahmud, Mohammad S; May, Gray R; Kamal, Mohammad M; Khwaja, Ahmed S; Sun, Carry; Vitkin, Alex; Yang, Victor XD

    2013-01-01

    An accurate, noninvasive and cost-effective method of in situ tissue evaluation during endoscopy would be highly advantageous for the detection of dysplasia or early cancer and for identifying different disease stages. Optical coherence tomography (OCT) is a noninvasive, high-resolution (1-10 μm) emerging optical imaging method with potential for identifying microscopic subsurface features in the pancreatic and biliary ductal system. Tissue microstructure of pancreaticobiliary ductal system has been successfully imaged by inserting an OCT probe through a standard endoscope operative channel. High-resolution OCT images and the technique’s endoscopic compatibility have allowed for the microstructural diagnostic of the pancreatobiliary diseases. In this review, we discussed currently available pancreaticobiliary ductal imaging systems to assess the pancreatobiliary tissue microstructure and to evaluate varieties of pancreaticobiliary disorders and diseases. Results show that OCT can improve the quality of images of pancreatobiliary system during endoscopic retrograde cholangiopancheatography procedure, which may be important in distinguishing between the neoplastic and non-neoplastic lesions. PMID:24255746

  5. In vivo white light and contrast-enhanced vital-dye fluorescence imaging of Barrett's-related neoplasia in a single-endoscopic insertion

    NASA Astrophysics Data System (ADS)

    Tang, Yubo; Carns, Jennifer; Polydorides, Alexandros D.; Anandasabapathy, Sharmila; Richards-Kortum, Rebecca R.

    2016-08-01

    A modular video endoscope is developed to enable both white light imaging (WLI) and vital-dye fluorescence imaging (VFI) in a single-endoscopic insertion for the early detection of cancer in Barrett's esophagus (BE). We demonstrate that VFI can be achieved in conjunction with white light endoscopy, where appropriate white balance is used to correct for the presence of the emission filter. In VFI mode, a contrast enhancement feature is implemented in real time to further highlight glandular patterns in BE and related malignancies without introducing artifacts. In a pilot study, we demonstrate accurate correlation of images in two widefield modalities, with representative images showing the disruption and effacement of glandular architecture associated with cancer development in BE. VFI images of these alterations exhibit enhanced contrast when compared to WLI. Results suggest that the usefulness of VFI in the detection of BE-related neoplasia should be further evaluated in future in vivo studies.

  6. Design and implementation of magnetically maneuverable capsule endoscope system with direction reference for image navigation.

    PubMed

    Sun, Zhen-Jun; Ye, Bo; Sun, Yi; Zhang, Hong-Hai; Liu, Sheng

    2014-07-01

    This article describes a novel magnetically maneuverable capsule endoscope system with direction reference for image navigation. This direction reference was employed by utilizing a specific magnet configuration between a pair of external permanent magnets and a magnetic shell coated on the external capsule endoscope surface. A pair of customized Cartesian robots, each with only 4 degrees of freedom, was built to hold the external permanent magnets as their end-effectors. These robots, together with their external permanent magnets, were placed on two opposite sides of a "patient bed." Because of the optimized configuration based on magnetic analysis between the external permanent magnets and the magnetic shell, a simplified control strategy was proposed, and only two parameters, yaw step angle and moving step, were necessary for the employed robotic system. Step-by-step experiments demonstrated that the proposed system is capable of magnetically maneuvering the capsule endoscope while providing direction reference for image navigation. © IMechE 2014.

  7. Real-time fusion of endoscopic views with dynamic 3-D cardiac images: a phantom study.

    PubMed

    Szpala, Stanislaw; Wierzbicki, Marcin; Guiraudon, Gerard; Peters, Terry M

    2005-09-01

    Minimally invasive robotically assisted cardiac surgical systems currently do not routinely employ 3-D image guidance. However, preoperative magnetic resonance and computed tomography (CT) images have the potential to be used in this role, if appropriately registered with the patient anatomy and animated synchronously with the motion of the actual heart. This paper discusses the fusion of optical images of a beating heart phantom obtained from an optically tracked endoscope, with volumetric images of the phantom created from a dynamic CT dataset. High quality preoperative dynamic CT images are created by first extracting the motion parameters of the heart from the series of temporal frames, and then applying this information to animate a high-quality heart image acquired at end systole. Temporal synchronization of the endoscopic and CT model is achieved by selecting the appropriate CT image from the dynamic set, based on an electrocardiographic trigger signal. The spatial error between the optical and virtual images is 1.4 +/- 1.1 mm, while the time discrepancy is typically 50-100 ms. Index Terms-Image guidance, image warping, minimally invasive cardiac surgery, virtual endoscopy, virtual reality.

  8. Microfabricated endoscopic probe integrated MEMS micromirror for optical coherence tomography bioimaging.

    PubMed

    Wang, Ming-Fang; Xu, Yingshun; Prem, C S; Chen, Kelvin Wei Sheng; Xie, Jin; Mu, Xiaojing; Tan, Chee Wei; Yu, Aibin; Feng, Hanhua

    2010-01-01

    In this paper, we present a miniaturized endoscopic probe, consisted of MEMS micromirror, silicon optical bench (SiOB), grade index (GRIN) lens, single mode optical fiber (SMF) and transparent housing, for optical coherence tomography (OCT) bioimaging. Due to the use of the MEMS micromirror, the endoscopic OCT system is highly suitable for non-invasive imaging diagnosis of a wide variety of inner organs. The probe engineering and proof of concept were demonstrated by obtaining the two-dimensional OCT images with a cover slide and an onion used as standard samples and the axial resolution was around 10µm.

  9. Implemented a wireless communication system for VGA capsule endoscope.

    PubMed

    Moon, Yeon-Kwan; Lee, Jyung Hyun; Park, Hee-Joon; Cho, Jin-Ho; Choi, Hyun-Chul

    2014-01-01

    Recently, several medical devices that use wireless communication are under development. In this paper, the small size frequency shift keying (FSK) transmitter and a monofilar antenna for the capsule endoscope, enabling the medical device to transmit VGA-size images of the intestine. To verify the functionality of the proposed wireless communication system, computer simulations and animal experiments were performed with the implemented capsule endoscope that includes the proposed wireless communication system. Several fundamental experiments are carried out using the implemented transmitter and antenna, and animal in-vivo experiments were performed to verify VGA image transmission.

  10. Cecal intubation rates in different eras of endoscopic technological development.

    PubMed

    Matyja, Maciej; Pasternak, Artur; Szura, Mirosław; Pędziwiatr, Michał; Major, Piotr; Rembiasz, Kazimierz

    2018-03-01

    Colonoscopy plays a critical role in colorectal cancer (CRC) screening and has been widely regarded as the gold standard. Cecal intubation rate (CIR) is one of the well-defined quality indicators used to assess colonoscopy. To assess the impact of new technologies on the quality of colonoscopy by assessing completion rates. This was a dual-center study at the 2 nd Department of Surgery at Jagiellonian University Medical College and at the Specialist Center "Medicina" in Krakow, Poland. The CIR and cecal intubation time (CIT) in three different eras of technological advancement were determined. The study enrolled 27 463 patients who underwent colonoscopy as part of a national CRC screening program. The patients were divided into three groups: group I - 3408 patients examined between 2000 and 2003 (optical endoscopes); group II - 10 405 patients examined between 2004 and 2008 (standard electronic endoscopes); and group III - 13 650 patients examined between 2009 and 2014 (modern endoscopes). There were statistically significant differences in the CIR between successive eras. The CIR in group I (2000-2003) was 69.75%, in group II (2004-2008) was 92.32%, and in group III (2009-2014) was 95.17%. The mean CIT was significantly reduced in group III. Our study shows that the technological innovation of novel endoscopy devices has a great influence on the effectiveness of the CRC screening program. The new era of endoscopic technological development has the potential to reduce examination-related patient discomfort, obviate the need for sedation and increase diagnostic yields.

  11. Objective characterization of airway dimensions using image processing.

    PubMed

    Pepper, Victoria K; Francom, Christian; Best, Cameron A; Onwuka, Ekene; King, Nakesha; Heuer, Eric; Mahler, Nathan; Grischkan, Jonathan; Breuer, Christopher K; Chiang, Tendy

    2016-12-01

    With the evolution of medical and surgical management for pediatric airway disorders, the development of easily translated techniques of measuring airway dimensions can improve the quantification of outcomes of these interventions. We have developed a technique that improves the ability to characterize endoscopic airway dimensions using common bronchoscopic equipment and an open-source image-processing platform. We validated our technique of Endoscopic Airway Measurement (EAM) using optical instruments in simulation tracheas. We then evaluated EAM in a large animal model (Ovis aries, n = 5), comparing tracheal dimensions obtained with EAM to measurements obtained via 3-D fluoroscopic reconstruction. The animal then underwent resection of the measured segment, and direct measurement of this segment was performed and compared to radiographic measurements and those obtained using EAM. The simulation tracheas had a direct measurement of 13.6, 18.5, and 24.2 mm in diameter. The mean difference of diameter in simulation tracheas between direct measurements and measurements obtained using EAM was 0.70 ± 0.57 mm. The excised ovine tracheas had an average diameter of 18.54 ± 0.68 mm. The percent difference in diameter obtained from EAM and from 3-D fluoroscopic reconstruction when compared to measurement of the excised tracheal segment was 4.98 ± 2.43% and 10.74 ± 4.07% respectively. Comparison of these three measurements (EAM, measurement of resected trachea, 3-D fluoroscopic reconstruction) with repeated measures ANOVA demonstrated no statistical significance. Endoscopic airway measurement (EAM) provides equivalent measurements of the airway with the improved versatility of measuring non-circular and multi-level dimensions. Using optical bronchoscopic instruments and open-source image-processing software, our data supports preclinical and clinical translation of an accessible technique to provide objective quantification of airway diameter. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Magnetic anchor guidance for endoscopic submucosal dissection and other endoscopic procedures

    PubMed Central

    Mortagy, Mohamed; Mehta, Neal; Parsi, Mansour A; Abe, Seiichiro; Stevens, Tyler; Vargo, John J; Saito, Yutaka; Bhatt, Amit

    2017-01-01

    Endoscopic submucosal dissection (ESD) is a well-established, minimally invasive treatment for superficial neoplasms of the gastrointestinal tract. The universal adoption of ESD has been limited by its slow learning curve, long procedure times, and high risk of complications. One technical challenge is the lack of a second hand that can provide traction, as in conventional surgery. Reliable tissue retraction that exposes the submucosal plane of dissection would allow for safer and more efficient dissection. Magnetic anchor guided endoscopic submucosal dissection (MAG-ESD) has potential benefits compared to other current traction methods. MAG-ESD offers dynamic tissue retraction independent of the endoscope mimicking a surgeon’s “second hand”. Two types of magnets can be used: electromagnets and permanent magnets. In this article we review the MAG-ESD technology, published work and studies of magnets in ESD. We also review the use of magnetic anchor guidance systems in natural orifice transluminal endoscopic surgery and the idea of magnetic non-contact retraction using surface ferromagentization. We discuss the current limitations, the future potential of MAG-ESD and the developments needed for adoption of this technology. PMID:28522906

  13. The transition from microscopic to endoscopic transsphenoidal surgery: the experience at Brigham and Women's Hospital.

    PubMed

    Laws, Edward R; Barkhoudarian, Garni

    2014-12-01

    As interest and enthusiasm for the use of the endoscope in transsphenoidal anterior skull base and pituitary surgery increases, neurosurgeons are increasingly adopting endoscopic technology and associated novel concepts. Often this involves a transition from the standard operating microscope as the main means of visualization to the operating endoscope (2D or 3D) during surgery. The authors' experience with this transition is described, including the rationale, advantages and disadvantages of the two surgical techniques. The successful use of endoscopic surgery for a large variety of pathological problems involving the anterior skull base and the pituitary region is presented. Perceived advantages for the patient and the surgeon are described, as is the occasional need for transition back to the microscopic approach. The endoscopic approach and its allied technology are here to stay. They are useful and occasionally preferable methods for treating a variety of suitable lesions involving the anterior skull base. The importance of incorporating the basic principles of skull base surgery is emphasized. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Automated high-level disinfection of nonchanneled flexible endoscopes: duty cycles and endoscope repair.

    PubMed

    Statham, Melissa McCarty; Willging, J Paul

    2010-10-01

    Guidelines issued by the Association of Operating Room Nurses and the Association of Professionals in Infection Control and Epidemiology recommend high-level disinfection (HLD) for semicritical instruments, such as flexible endoscopes. We aim to examine the durability of endoscopes to continued use and automated HLD. We report the number of duty cycles a flexible endoscope can withstand before repairs should be anticipated. Retrospective review. A total of 4,336 endoscopic exams and subsequent disinfection cycles were performed with 60 flexible endoscopes in an outpatient tertiary pediatric otolaryngology practice from 2005 to 2009. All endoscopes were systemically cleaned with mechanical cleansing followed by leak testing, enzymatic cleaning, and exposure to Orthophthaldehyde (0.55%) for 5 minutes at a temperature of at least 25°C, followed by rinsing for 3 minutes. A total of 77 repairs were performed, 48 major (average cost $3,815.97), and 29 minor (average cost $326.85). On average, the 2.2-mm flexible endoscopes were utilized for 61.9 examinations before major repair was needed, whereas the 3.6 mm endoscopes were utilized for 154.5 exams before needing minor repairs. No major repairs have been needed to date on the 3.6-mm endoscopes. Automated endoscope reprocessor use for HLD is an effective means to disinfect and process flexible endoscopes. This minimizes variability in the processing of the endoscopes and maximizes the rate of successful HLD. Even when utilizing standardized, automated HLD and limiting the number of personnel processing the endoscopes, smaller fiberoptic endoscopes demonstrate a shortened time interval between repairs than that seen with the larger endoscopes. Laryngoscope, 2010.

  15. Ultrathin endoscopes based on multicore fibers and adaptive optics: a status review and perspectives.

    PubMed

    Andresen, Esben Ravn; Sivankutty, Siddharth; Tsvirkun, Viktor; Bouwmans, Géraud; Rigneault, Hervé

    2016-12-01

    We take stock of the progress that has been made into developing ultrathin endoscopes assisted by wave front shaping. We focus our review on multicore fiber-based lensless endoscopes intended for multiphoton imaging applications. We put the work into perspective by comparing with alternative approaches and by outlining the challenges that lie ahead.

  16. WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, W; Rao, A; Wendt, R

    Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded asmore » it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration framework that is clinically valuable and requires no specialized equipment.« less

  17. Quantitative evaluation of in vivo vital-dye fluorescence endoscopic imaging for the detection of Barrett’s-associated neoplasia

    PubMed Central

    Thekkek, Nadhi; Lee, Michelle H.; Polydorides, Alexandros D.; Rosen, Daniel G.; Anandasabapathy, Sharmila; Richards-Kortum, Rebecca

    2015-01-01

    Abstract. Current imaging tools are associated with inconsistent sensitivity and specificity for detection of Barrett’s-associated neoplasia. Optical imaging has shown promise in improving the classification of neoplasia in vivo. The goal of this pilot study was to evaluate whether in vivo vital dye fluorescence imaging (VFI) has the potential to improve the accuracy of early-detection of Barrett’s-associated neoplasia. In vivo endoscopic VFI images were collected from 65 sites in 14 patients with confirmed Barrett’s esophagus (BE), dysplasia, or esophageal adenocarcinoma using a modular video endoscope and a high-resolution microendoscope (HRME). Qualitative image features were compared to histology; VFI and HRME images show changes in glandular structure associated with neoplastic progression. Quantitative image features in VFI images were identified for objective image classification of metaplasia and neoplasia, and a diagnostic algorithm was developed using leave-one-out cross validation. Three image features extracted from VFI images were used to classify tissue as neoplastic or not with a sensitivity of 87.8% and a specificity of 77.6% (AUC=0.878). A multimodal approach incorporating VFI and HRME imaging can delineate epithelial changes present in Barrett’s-associated neoplasia. Quantitative analysis of VFI images may provide a means for objective interpretation of BE during surveillance. PMID:25950645

  18. Quantitative evaluation of in vivo vital-dye fluorescence endoscopic imaging for the detection of Barrett's-associated neoplasia.

    PubMed

    Thekkek, Nadhi; Lee, Michelle H; Polydorides, Alexandros D; Rosen, Daniel G; Anandasabapathy, Sharmila; Richards-Kortum, Rebecca

    2015-05-01

    Current imaging tools are associated with inconsistent sensitivity and specificity for detection of Barrett's-associated neoplasia. Optical imaging has shown promise in improving the classification of neoplasia in vivo. The goal of this pilot study was to evaluate whether in vivo vital dye fluorescence imaging (VFI) has the potential to improve the accuracy of early-detection of Barrett's-associated neoplasia. In vivo endoscopic VFI images were collected from 65 sites in 14 patients with confirmed Barrett's esophagus (BE), dysplasia, oresophageal adenocarcinoma using a modular video endoscope and a high-resolution microendoscope(HRME). Qualitative image features were compared to histology; VFI and HRME images show changes in glandular structure associated with neoplastic progression. Quantitative image features in VFI images were identified for objective image classification of metaplasia and neoplasia, and a diagnostic algorithm was developed using leave-one-out cross validation. Three image features extracted from VFI images were used to classify tissue as neoplastic or not with a sensitivity of 87.8% and a specificity of 77.6% (AUC = 0.878). A multimodal approach incorporating VFI and HRME imaging can delineate epithelial changes present in Barrett's-associated neoplasia. Quantitative analysis of VFI images may provide a means for objective interpretation of BE during surveillance.

  19. Importance of histological evaluation in endoscopic resection of early colorectal cancer

    PubMed Central

    Yoshida, Naohisa; Naito, Yuji; Yagi, Nobuaki; Yanagisawa, Akio

    2012-01-01

    The diagnostic criteria for colonic intraepithelial tumors vary from country to country. While intramucosal adenocarcinoma is recognized in Japan, in Western countries adenocarcinoma is diagnosed only if the tumor invades to the submucosa and accesses the muscularis mucosae. However, endoscopic therapy, including endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD), is used worldwide to treat adenoma and early colorectal cancer. Precise histopathological evaluation is important for the curativeness of these therapies as inappropriate endoscopic therapy causes local recurrence of the tumor that may develop into fatal metastasis. Therefore, colorectal ESD and EMR are not indicated for cancers with massive submucosal invasion. However, diagnosis of cancer with massive submucosal invasion by endoscopy is limited, even when magnifying endoscopy for pit pattern and narrow band imaging and flexible spectral imaging color of enhancement are performed. Therefore, occasional cancers with massive submucosal invasion will be treated by ESD and EMR. Precise histopathological evaluation of these lesions should be performed in order to determine the necessity of additional therapy, including surgical resection. PMID:22532932

  20. Image-Based Navigation for Functional Endoscopic Sinus Surgery Using Structure From Motion.

    PubMed

    Leonard, Simon; Reiter, Austin; Sinha, Ayushi; Ishii, Masaru; Taylor, Russel H; Hager, Gregory D

    2016-01-01

    Functional Endoscopic Sinus Surgery (FESS) is a challenging procedure for otolaryngologists and is the main surgical approach for treating chronic sinusitis, to remove nasal polyps and open up passageways. To reach the source of the problem and to ultimately remove it, the surgeons must often remove several layers of cartilage and tissues. Often, the cartilage occludes or is within a few millimeters of critical anatomical structures such as nerves, arteries and ducts. To make FESS safer, surgeons use navigation systems that register a patient to his/her CT scan and track the position of the tools inside the patient. Current navigation systems, however, suffer from tracking errors greater than 1 mm, which is large when compared to the scale of the sinus cavities, and errors of this magnitude prevent from accurately overlaying virtual structures on the endoscope images. In this paper, we present a method to facilitate this task by 1) registering endoscopic images to CT data and 2) overlaying areas of interests on endoscope images to improve the safety of the procedure. First, our system uses structure from motion (SfM) to generate a small cloud of 3D points from a short video sequence. Then, it uses iterative closest point (ICP) algorithm to register the points to a 3D mesh that represents a section of a patients sinuses. The scale of the point cloud is approximated by measuring the magnitude of the endoscope's motion during the sequence. We have recorded several video sequences from five patients and, given a reasonable initial registration estimate, our results demonstrate an average registration error of 1.21 mm when the endoscope is viewing erectile tissues and an average registration error of 0.91 mm when the endoscope is viewing non-erectile tissues. Our implementation SfM + ICP can execute in less than 7 seconds and can use as few as 15 frames (0.5 second of video). Future work will involve clinical validation of our results and strengthening the robustness to initial guesses and erectile tissues.

  1. Image-based navigation for functional endoscopic sinus surgery using structure from motion

    NASA Astrophysics Data System (ADS)

    Leonard, Simon; Reiter, Austin; Sinha, Ayushi; Ishii, Masaru; Taylor, Russell H.; Hager, Gregory D.

    2016-03-01

    Functional Endoscopic Sinus Surgery (FESS) is a challenging procedure for otolaryngologists and is the main surgical approach for treating chronic sinusitis, to remove nasal polyps and open up passageways. To reach the source of the problem and to ultimately remove it, the surgeons must often remove several layers of cartilage and tissues. Often, the cartilage occludes or is within a few millimeters of critical anatomical structures such as nerves, arteries and ducts. To make FESS safer, surgeons use navigation systems that register a patient to his/her CT scan and track the position of the tools inside the patient. Current navigation systems, however, suffer from tracking errors greater than 1 mm, which is large when compared to the scale of the sinus cavities, and errors of this magnitude prevent from accurately overlaying virtual structures on the endoscope images. In this paper, we present a method to facilitate this task by 1) registering endoscopic images to CT data and 2) overlaying areas of interests on endoscope images to improve the safety of the procedure. First, our system uses structure from motion (SfM) to generate a small cloud of 3D points from a short video sequence. Then, it uses iterative closest point (ICP) algorithm to register the points to a 3D mesh that represents a section of a patients sinuses. The scale of the point cloud is approximated by measuring the magnitude of the endoscope's motion during the sequence. We have recorded several video sequences from five patients and, given a reasonable initial registration estimate, our results demonstrate an average registration error of 1.21 mm when the endoscope is viewing erectile tissues and an average registration error of 0.91 mm when the endoscope is viewing non-erectile tissues. Our implementation SfM + ICP can execute in less than 7 seconds and can use as few as 15 frames (0.5 second of video). Future work will involve clinical validation of our results and strengthening the robustness to initial guesses and erectile tissues.

  2. Capturing and stitching images with a large viewing angle and low distortion properties for upper gastrointestinal endoscopy

    NASA Astrophysics Data System (ADS)

    Liu, Ya-Cheng; Chung, Chien-Kai; Lai, Jyun-Yi; Chang, Han-Chao; Hsu, Feng-Yi

    2013-06-01

    Upper gastrointestinal endoscopies are primarily performed to observe the pathologies of the esophagus, stomach, and duodenum. However, when an endoscope is pushed into the esophagus or stomach by the physician, the organs behave similar to a balloon being gradually inflated. Consequently, their shapes and depth-of-field of images change continually, preventing thorough examination of the inflammation or anabrosis position, which delays the curing period. In this study, a 2.9-mm image-capturing module and a convoluted mechanism was incorporated into the tube like a standard 10- mm upper gastrointestinal endoscope. The scale-invariant feature transform (SIFT) algorithm was adopted to implement disease feature extraction on a koala doll. Following feature extraction, the smoothly varying affine stitching (SVAS) method was employed to resolve stitching distortion problems. Subsequently, the real-time splice software developed in this study was embedded in an upper gastrointestinal endoscope to obtain a panoramic view of stomach inflammation in the captured images. The results showed that the 2.9-mm image-capturing module can provide approximately 50 verified images in one spin cycle, a viewing angle of 120° can be attained, and less than 10% distortion can be achieved in each image. Therefore, these methods can solve the problems encountered when using a standard 10-mm upper gastrointestinal endoscope with a single camera, such as image distortion, and partial inflammation displays. The results also showed that the SIFT algorithm provides the highest correct matching rate, and the SVAS method can be employed to resolve the parallax problems caused by stitching together images of different flat surfaces.

  3. Endoscope field of view measurement.

    PubMed

    Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen

    2017-03-01

    The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOV WS method) in the current ISO 8600-3 standard and proposed a new method (the FOV EP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOV EP method was more accurate than the FOV WS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard.

  4. Endoscope field of view measurement

    PubMed Central

    Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen

    2017-01-01

    The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOVWS method) in the current ISO 8600-3 standard and proposed a new method (the FOVEP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOVEP method was more accurate than the FOVWS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard. PMID:28663840

  5. A Knowledge-Based System for the Computer Assisted Diagnosis of Endoscopic Images

    NASA Astrophysics Data System (ADS)

    Kage, Andreas; Münzenmayer, Christian; Wittenberg, Thomas

    Due to the actual demographic development the use of Computer-Assisted Diagnosis (CAD) systems becomes a more important part of clinical workflows and clinical decision making. Because changes on the mucosa of the esophagus can indicate the first stage of cancerous developments, there is a large interest to detect and correctly diagnose any such lesion. We present a knowledge-based system which is able to support a physician with the interpretation and diagnosis of endoscopic images of the esophagus. Our system is designed to support the physician directly during the examination of the patient, thus prodving diagnostic assistence at the point of care (POC). Based on an interactively marked region in an endoscopic image of interest, the system provides a diagnostic suggestion, based on an annotated reference image database. Furthermore, using relevant feedback mechanisms, the results can be enhanced interactively.

  6. Optical Design with Narrow-Band Imaging for a Capsule Endoscope.

    PubMed

    Yen, Chih-Ta; Lai, Zong-Wei; Lin, Yu-Ting; Cheng, Hsu-Chih

    2018-01-01

    The study proposes narrow-band imaging (NBI) lens design of 415 nm and 540 nm of a capsule endoscope (CE). The researches show that in terms of the rate of accuracy in detecting and screening neoplastic and nonneoplastic intestinal lesions, the NBI system outperformed that of traditional endoscopes and rivaled that of chromoendoscopes. In the proposed NBI CE optical system, the simulation result shows the field of view (FOV) was 109.8°; the modulation transfer function (MTF) could achieve 12.5% at 285 lp/mm and 34.1% at 144 lp/mm. The relative illumination reaches more than 60%, and the system total length was less than 4 mm. Finally, this design provides high-quality images for a 300-megapixel 1/4 ″ CMOS image sensor with a pixel size of 1.75  μ m.

  7. Image navigation as a means to expand the boundaries of fluorescence-guided surgery

    NASA Astrophysics Data System (ADS)

    Brouwer, Oscar R.; Buckle, Tessa; Bunschoten, Anton; Kuil, Joeri; Vahrmeijer, Alexander L.; Wendler, Thomas; Valdés-Olmos, Renato A.; van der Poel, Henk G.; van Leeuwen, Fijs W. B.

    2012-05-01

    Hybrid tracers that are both radioactive and fluorescent help extend the use of fluorescence-guided surgery to deeper structures. Such hybrid tracers facilitate preoperative surgical planning using (3D) scintigraphic images and enable synchronous intraoperative radio- and fluorescence guidance. Nevertheless, we previously found that improved orientation during laparoscopic surgery remains desirable. Here we illustrate how intraoperative navigation based on optical tracking of a fluorescence endoscope may help further improve the accuracy of hybrid surgical guidance. After feeding SPECT/CT images with an optical fiducial as a reference target to the navigation system, optical tracking could be used to position the tip of the fluorescence endoscope relative to the preoperative 3D imaging data. This hybrid navigation approach allowed us to accurately identify marker seeds in a phantom setup. The multispectral nature of the fluorescence endoscope enabled stepwise visualization of the two clinically approved fluorescent dyes, fluorescein and indocyanine green. In addition, the approach was used to navigate toward the prostate in a patient undergoing robot-assisted prostatectomy. Navigation of the tracked fluorescence endoscope toward the target identified on SPECT/CT resulted in real-time gradual visualization of the fluorescent signal in the prostate, thus providing an intraoperative confirmation of the navigation accuracy.

  8. Design and analysis of radial imaging capsule endoscope (RICE) system.

    PubMed

    Ou-Yang, Mang; Jeng, Wei-De

    2011-02-28

    In this study, a radial imaging capsule endoscope (RICE) system is designed, which differs from a conventional front imaging capsule endoscope (FICE) system. To observe the wrinkled intima of the intestine, which spreads without folding around the circumference of the capsule when a capsule endoscope with a diameter that slightly exceeds that of the intestine passes through it, the RICE uses a cone mirror, a radial window shell, and a focus optical module that comprise the radial imaging system. This concept was demonstrated in a packaged optical simulator. The RICE optical model also has been established and verified by many simulations and experiments. In minimizing the sagittal and tangential aberrations, the optical module of the RICE has achieved an F-number of 4.2, a viewing angle of 65.08°, and an RMS radius of the 4th to 6th fields of less than 17 um. A comparison of these characteristics with those of the focus optical module that is used in FICE lenses reveals that the spot size is 50% larger for each field, and the modulation transfer function (MTF) is remarkably improved from 7% to 36% at 100 lp/mm on the 5th field of the sagittal plane.

  9. A low-cost multimodal head-mounted display system for neuroendoscopic surgery.

    PubMed

    Xu, Xinghua; Zheng, Yi; Yao, Shujing; Sun, Guochen; Xu, Bainan; Chen, Xiaolei

    2018-01-01

    With rapid advances in technology, wearable devices as head-mounted display (HMD) have been adopted for various uses in medical science, ranging from simply aiding in fitness to assisting surgery. We aimed to investigate the feasibility and practicability of a low-cost multimodal HMD system in neuroendoscopic surgery. A multimodal HMD system, mainly consisted of a HMD with two built-in displays, an action camera, and a laptop computer displaying reconstructed medical images, was developed to assist neuroendoscopic surgery. With this intensively integrated system, the neurosurgeon could freely switch between endoscopic image, three-dimensional (3D) reconstructed virtual endoscopy images, and surrounding environment images. Using a leap motion controller, the neurosurgeon could adjust or rotate the 3D virtual endoscopic images at a distance to better understand the positional relation between lesions and normal tissues at will. A total of 21 consecutive patients with ventricular system diseases underwent neuroendoscopic surgery with the aid of this system. All operations were accomplished successfully, and no system-related complications occurred. The HMD was comfortable to wear and easy to operate. Screen resolution of the HMD was high enough for the neurosurgeon to operate carefully. With the system, the neurosurgeon might get a better comprehension on lesions by freely switching among images of different modalities. The system had a steep learning curve, which meant a quick increment of skill with it. Compared with commercially available surgical assistant instruments, this system was relatively low-cost. The multimodal HMD system is feasible, practical, helpful, and relatively cost efficient in neuroendoscopic surgery.

  10. Full image-processing pipeline in field-programmable gate array for a small endoscopic camera

    NASA Astrophysics Data System (ADS)

    Mostafa, Sheikh Shanawaz; Sousa, L. Natércia; Ferreira, Nuno Fábio; Sousa, Ricardo M.; Santos, Joao; Wäny, Martin; Morgado-Dias, F.

    2017-01-01

    Endoscopy is an imaging procedure used for diagnosis as well as for some surgical purposes. The camera used for the endoscopy should be small and able to produce a good quality image or video, to reduce discomfort of the patients, and to increase the efficiency of the medical team. To achieve these fundamental goals, a small endoscopy camera with a footprint of 1 mm×1 mm×1.65 mm is used. Due to the physical properties of the sensors and human vision system limitations, different image-processing algorithms, such as noise reduction, demosaicking, and gamma correction, among others, are needed to faithfully reproduce the image or video. A full image-processing pipeline is implemented using a field-programmable gate array (FPGA) to accomplish a high frame rate of 60 fps with minimum processing delay. Along with this, a viewer has also been developed to display and control the image-processing pipeline. The control and data transfer are done by a USB 3.0 end point in the computer. The full developed system achieves real-time processing of the image and fits in a Xilinx Spartan-6LX150 FPGA.

  11. Molecular imaging for theranostics in gastroenterology: one stone to kill two birds.

    PubMed

    Ko, Kwang Hyun; Kown, Chang-Il; Park, Jong Min; Lee, Hoo Geun; Han, Na Young; Hahm, Ki Baik

    2014-09-01

    Molecular imaging in gastroenterology has become more feasible with recent advances in imaging technology, molecular genetics, and next-generation biochemistry, in addition to advances in endoscopic imaging techniques including magnified high-resolution endoscopy, narrow band imaging or autofluorescence imaging, flexible spectral imaging color enhancement, and confocal laser endomicroscopy. These developments have the potential to serve as "red flag" techniques enabling the earlier and accurate detection of mucosal abnormalities (such as precancerous lesions) beyond biomarkers, virtual histology of detected lesions, and molecular targeted therapy-the strategy of "one stone to kill two or three birds"; however, more effort should be done to be "blue ocean" benefit. This review deals with the introduction of Raman spectroscopy endoscopy, imaging mass spectroscopy, and nanomolecule development for theranostics. Imaging of molecular pathological changes in cells/tissues/organs might open the "royal road" to either convincing diagnosis of diseases that otherwise would only be detected in the advanced stages or novel therapeutic methods targeted to personalized medicine.

  12. Monitoring blood-flow in the mouse cochlea using an endoscopic laser speckle contrast imaging system

    PubMed Central

    Yu, Sunkon; Jung, Byungjo; Choi, Jin Sil

    2018-01-01

    Laser speckle contrast imaging (LSCI) enables continuous high-resolution assessment of microcirculation in real-time. We applied an endoscope to LSCI to measure cochlear blood-flow in an ischemia–reperfusion mouse model. We also explored whether using xenon light in combination with LSCI facilitates visualization of anatomical position. Based on a previous preliminary study, the appropriate wavelength for penetrating the thin bony cochlea was 830 nm. A 2.7-mm-diameter endoscope was used, as appropriate for the size of the mouse cochlea. Our endoscopic LSCI system was used to illuminate the right cochlea after dissection of the mouse. We observed changes in the speckle signals when we applied the endoscopic LSCI system to the ischemia-reperfusion mouse model. The anatomical structure of the mouse cochlea and surrounding structures were clearly visible using the xenon light. The speckle signal of the cochlea was scattered, with an intensity that varied between that of the stapes (with the lowest signal), the negative control, and the stapedial artery (with the highest signal), the positive control. In the cochlear ischemia–reperfusion mouse model, the speckle signal of the cochlea decreased during the ischemic phase, and increased during the reperfusion phase, clearly reflecting cochlear blood-flow. The endoscopic LSCI system generates high-resolution images in real-time, allowing visualization of blood-flow and its changes in the mouse cochlea. Anatomical structures were clearly matched using LSCI along with visible light. PMID:29489849

  13. Monitoring blood-flow in the mouse cochlea using an endoscopic laser speckle contrast imaging system.

    PubMed

    Kong, Tae Hoon; Yu, Sunkon; Jung, Byungjo; Choi, Jin Sil; Seo, Young Joon

    2018-01-01

    Laser speckle contrast imaging (LSCI) enables continuous high-resolution assessment of microcirculation in real-time. We applied an endoscope to LSCI to measure cochlear blood-flow in an ischemia-reperfusion mouse model. We also explored whether using xenon light in combination with LSCI facilitates visualization of anatomical position. Based on a previous preliminary study, the appropriate wavelength for penetrating the thin bony cochlea was 830 nm. A 2.7-mm-diameter endoscope was used, as appropriate for the size of the mouse cochlea. Our endoscopic LSCI system was used to illuminate the right cochlea after dissection of the mouse. We observed changes in the speckle signals when we applied the endoscopic LSCI system to the ischemia-reperfusion mouse model. The anatomical structure of the mouse cochlea and surrounding structures were clearly visible using the xenon light. The speckle signal of the cochlea was scattered, with an intensity that varied between that of the stapes (with the lowest signal), the negative control, and the stapedial artery (with the highest signal), the positive control. In the cochlear ischemia-reperfusion mouse model, the speckle signal of the cochlea decreased during the ischemic phase, and increased during the reperfusion phase, clearly reflecting cochlear blood-flow. The endoscopic LSCI system generates high-resolution images in real-time, allowing visualization of blood-flow and its changes in the mouse cochlea. Anatomical structures were clearly matched using LSCI along with visible light.

  14. Import and visualization of clinical medical imagery into multiuser VR environments

    NASA Astrophysics Data System (ADS)

    Mehrle, Andreas H.; Freysinger, Wolfgang; Kikinis, Ron; Gunkel, Andreas; Kral, Florian

    2005-03-01

    The graphical representation of three-dimensional data obtained from tomographic imaging has been the central problem since this technology is available. Neither the representation as a set of two-dimensional slices nor the 2D projection of three-dimensional models yields satisfactory results. In this paper a way is outlined which permits the investigation of volumetric clinical data obtained from standard CT, MR, PET, SPECT or experimental very high resolution CT-scanners in a three dimensional environment within a few worksteps. Volumetric datasets are converted into surface data (segmentation process) using the 3D-Slicer software tool and saved as .vtk files and exported as a collection of primitives in any common file format (.iv, .pfb). Subsequently this files can be displayed and manipulated in the CAVE virtual reality center. The CAVE is a multiuser walkable virtual room consisting of several walls on which stereoscopic images are projected by rear panel beamers. Adequate tracking of the head position and separate image calculation for each eye yields a vivid impression for one or several users. With the use of a seperately tracked 6D joystick manipulations such as rotation, translation, zooming, decomposition or highlighting can be done intuitively. The usage of the CAVE technology opens new possibilities especially in surgical training ("hands-on-effect") and as an educational tool (availability of pathological data). Unlike concurring technologies the CAVE permits a walk-through into the virtual scene but preserves enough physical perception to allow interaction between multiple users, e.g. gestures and movements. By training in a virtual environment on one hand the learning process of students in complex anatomic findings may be improved considerably and on the other hand unaccustomed views such as the one through a microscope or endoscope can be trained in advance. The availability of low-cost PC based CAVE-like systems and the rapidly decreasing price of high-performance video beamers makes the CAVE an affordable alternative to conventional surgical training techniques and without limitations in handling cadavers.

  15. A High-Resolution Endoscope of Small Diameter Using Electromagnetically Vibration of Single Fiber

    NASA Astrophysics Data System (ADS)

    Matsunaga, Tadao; Hino, Ryunosuke; Makishi, Wataru; Esashi, Masayoshi; Haga, Yoichi

    For high resolution visual inspection in the narrow space of the human body, small diameter endoscope has been developed which utilize electromagnetically vibration of single fiber. Thin endoscopes are effective for inspection in the narrow space of the human body, for example, in the blood vessel, lactiferous duct for detection infiltration of breast cancer, and periodontal gap between gingiva and tooth. This endoscope consists of single optical fiber and photofabricated driving coils. A collimator lens and a cylindrical permanent magnet are fixed on the optical fiber, and the tilted driving coils have been patterned on a 1.08 mm outer diameter thin tube. The fiber is positioned at the center of the tube which is patterned the coils. When an electrical alternating current at the resonance frequency is supplied to the coils, the permanent magnet which is fixed to the fiber is vibrated electromagnetically and scanned one or two dimensionally. This paper reports small diameter endoscope by using electromagnetically vibration of single fiber. Optical coherence tomography imaging has also been carried out with the fabricated endoscope and cross-section image of sub-surface skin of thumb was observed.

  16. Analysis of Preoperative Airway Examination with the CMOS Video Rhino-laryngoscope.

    PubMed

    Tsukamoto, Masanori; Hitosugi, Takashi; Yokoyama, Takeshi

    2017-05-01

    Endoscopy is one of the most useful clinical techniques in difficult airway management Comparing with the fibroptic endoscope, this compact device is easy to operate and can provide the clear image. In this study, we investigated its usefulness in the preoperative examination of endoscopy. Patients undergoing oral maxillofacial surgery were enrolled in this study. We performed preoperative airway examination by electronic endoscope (The CMOS video rhino-laryngoscope, KARL STORZ Endoscopy Japan, Tokyo). The system is composed of a videoendoscope, a compact video processor and a video recorder. In addition, the endoscope has a small color charge coupled device (CMOS) chip built into the tip of the endoscope. The outer diameter of the tip of this scope is 3.7 mm. In this study, electronic endoscope was used for preoperative airway examination in 7 patients. The preoperative airway examination with electronic endoscope was performed successfully in all the patients except one patient The patient had the symptoms such as nausea and vomiting at the examination. We could perform preoperative airway examination with excellent visualization and convenient recording of video sequence images with the CMOS video rhino-laryngoscope. It might be a especially useful device for the patients of difficult airways.

  17. Sensitivity of endoscopic ultrasound, multidetector computed tomography, and magnetic resonance cholangiopancreatography in the diagnosis of pancreas divisum: a tertiary center experience.

    PubMed

    Kushnir, Vladimir M; Wani, Sachin B; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris M; Mullady, Daniel K; Jonnalagadda, Sreenivasa S; Early, Dayna S; Edmundowicz, Steven A; Azar, Riad R

    2013-04-01

    There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: (1) evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP), and multidetector computed tomography (MDCT) for pancreas divisum; and (2) assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent endoscopic retrograde pancreatography and cross-sectional imaging. The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than the sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) (P < 0.001 for each). On review by expert radiologists, the sensitivity of MDCT increased to 83.3% in cases where the pancreatic duct was visualized, with fair IOA (κ = 0.34). Expert review of MRCPs did not identify any additional cases of pancreas divisum; IOA was moderate (κ = 0.43). Endoscopic ultrasound is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum.

  18. Software-assisted live visualization system for subjacent blood vessels in endonasal endoscopic approaches

    NASA Astrophysics Data System (ADS)

    Lempe, B.; Taudt, Ch.; Maschke, R.; Gruening, J.; Ernstberger, M.; Basan, F.; Baselt, T.; Grunert, R.; Hartmann, P.

    2013-02-01

    Minimal invasive surgery methods have received growing attention in recent years. In vital important areas, it is crucial for the surgeon to have a precise knowledge of the tissue structure. Especially the visualization of arteries is desirable, as the destruction of the same can be lethal to the patient. In order to meet this requirement, the study presents a novel assistance system for endoscopic surgery. While state-of-the art systems rely on pre-operational data like computer-tomographic maps and require the use of radiation, the goal of the presented approach is to provide the clarification of subjacent blood vessels on live images of the endoscope camera system. Based on the transmission and reflection spectra of various human tissues, a prototype system with a NIR illumination unit working at 808 nm was established. Several image filtering, processing and enhancement techniques have been investigated and evaluated on the raw pictures in order to obtain high quality results. The most important were increasing contrast and thresholding by difference of Gaussian method. Based on that, it is possible to rectify a fragmented artery pattern and extract geometrical information about the structure in terms of position and orientation. By superposing the original image and the extracted segment, the surgeon is assisted with valuable live pictures of the region of interest. The whole system has been tested on a laboratory scale. An outlook on the integration of such a system in a clinical environment and obvious benefits are discussed.

  19. Comparison of organic electroluminescence and liquid crystal displays for clinical utility in orthopedic endoscopic surgery.

    PubMed

    Dezawa, Akira; Sairyo, Koichi

    2014-05-01

    Organic electroluminescence displays (OELD) use organic materials that self-emit light with the passage of an electric current. OELD provide high contrast, excellent color reproducibility at low brightness, excellent video images, and less restricted viewing angles. OELD are thus promising for medical use. This study compared the utility of an OELD with conventional liquid crystal displays (LCD) for imaging in orthopedic endoscopic surgery. One OELD and two conventional LCD that were indistinguishable in external appearance were used in this study. Images from 18 patients were displayed simultaneously on three monitors and evaluated by six orthopedic surgeons with extensive surgical experience. Images were shown for 2 min, repeated twice, and viewed from the front and side (diagonally). Surgeon rated both clinical utility (12 parameters) and image quality (11 parameters) for each image on a 5-point scale: 1, very good; 2, good; 3, average; 4, poor; and 5, very poor. For clinical utility in 16 percutaneous endoscopic discectomy cases, mean scores for all 12 parameters were significantly better on the OELD than on the LCD, including organ distinguishability (2.1 vs 3.2, respectively), lesion identification (2.2 vs 3.1), and overall viewing impression (2.1 vs 3.1). For image quality, all 11 parameters were better on the OELD than on LCD. Significant differences were identified in six parameters, including contrast (1.8 vs 2.9), color reproducibility in dark areas (1.8 vs 2.9), and viewing angle (2.2 vs 2.9). The high contrast and excellent color reproducibility of the OELD reduced the constraints of imaging under endoscopy, in which securing a field of view may be difficult. Distinguishability of organs was good, including ligaments, dura mater, nerves, and adipose tissue, contributing to good stereoscopic images of the surgical field. These findings suggest the utility of OELD for excellent display of surgical images and for enabling safe and highly accurate endoscopic surgery. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  20. The cranial nuchal bursa: anatomy, ultrasonography, magnetic resonance imaging and endoscopic approach.

    PubMed

    Abuja, G A; García-López, J M; Manso-Díaz, G; Spoormakers, T J P; Taeymans, O

    2014-11-01

    Although an uncommon condition, cranial nuchal bursitis can affect the performance of the equine athlete. The anatomy is not well described and there are no reports of diagnostic imaging for endoscopic approaches. To describe the anatomy, ultrasonographic and magnetic resonance features of and endoscopic approach to the cranial nuchal bursa in horses. Experimental cadaver study. Four cranial nuchal bursae were dissected, 4 specimens were frozen to prepare anatomical sections and 2 were injected with latex to document surface landmarks and topographical anatomy and to identify the possible sites for endoscopic access. Six cadaveric specimens were used to describe the ultrasonographic and magnetic resonance features of the cranial nuchal bursa before and after intrabursal injection. Sixteen cadaver specimens were evaluated with a rigid arthroscope and gross dissection to determine the endoscopic appearance of the bursa. The cranial nuchal bursa could be identified consistently in all cadavers, using ultrasonographic and magnetic resonance on both pre- and post injection specimens. Cranial and caudal endoscopic approaches and instrument portals were developed for the cranial nuchal bursa. Using either approach, the entire extent of the bursa could be evaluated, but separate approaches for left and right compartments of the bursa were needed owing to the lack of manoeuvrability when examining the contralateral compartment. The cranial nuchal bursa can be identified on ultrasonographic and magnetic resonance images. An endoscopic approach to the cranial nuchal bursa is clinically feasible and offered an easy, repeatable entry into the cranial nuchal bursa, which allowed adequate observation of the structures within the bursa. This may be of help for diagnosis and treatment of conditions affecting the cranial nuchal bursa in horses. © 2014 EVJ Ltd.

  1. Rigid confocal endoscopy for in vivo imaging of experimental oral squamous intra-epithelial lesions.

    PubMed

    Farahati, Behnaz; Stachs, Oliver; Prall, Friedrich; Stave, Joachim; Guthoff, Rudolf; Pau, Hans Wilhelm; Just, Tino

    2010-04-01

    A rigid confocal endoscope has been developed to assess the oral squamous epithelium of mice and to determine sensitivity, specificity, and accuracy of this new technology. This endoscope is connected to the commercially available Heidelberg Retina Tomograph (HRT). HRT is a device with a 670-nm diode laser designed to acquire topographical measurements of the optic nerve head. Real-time rigid confocal endoscopy is demonstrated by imaging the epithelial lesions of a mice model. Six-week-old male C57Bl/6 mice were randomly divided into a non-treated group (n = 10) and into a 4-nitroquinoline 1-oxide (4-NQO)-treated group (n = 50). In the 4-NQO-treated group, the mice obtained 4-nitroquinoline 1-oxide in the drinking water (100 microg/ml) to induce tumourigenesis in the mouse tongue. The 4-NQO-solution was diluted in the drinking water for mice. After an 8-16-week carcinogen treatment with 4-NQO (ad libitum), mouse tongues were dissected within 3 h after CO(2) overdose. After confocal microscopy of all lesions of the tongue, conventional histopathological investigation was performed. The inter-rater reliability for the two observers of the confocal microscopic findings was found to be Kappa = 0.59 (P < 0.001). The penetration depth varied in the healthy tissue of the underside of the tongue throughout this study and was measured between 104 and 240 microm. In keratotic lesions, the penetration depths were diminished and varied between 80 and 140 microm. Strong keratinization inhibits the evaluation of the epithelium. For differentiation between low-grade and high-grade squamous intra-epithelial lesions, a sensitivity and specificity of 73% and 88% was reached. The animal experiment with this non-invasive new technology indicates that this imaging technology facilitates the detection of pre-cancerous lesions of the underside of the oropharynx. Human studies on oropharyngeal and laryngeal lesions are needed to prove the applicability of this method in the field of otorhinolaryngology.

  2. Computer-aided diagnosis of colorectal polyp histology by using a real-time image recognition system and narrow-band imaging magnifying colonoscopy.

    PubMed

    Kominami, Yoko; Yoshida, Shigeto; Tanaka, Shinji; Sanomura, Yoji; Hirakawa, Tsubasa; Raytchev, Bisser; Tamaki, Toru; Koide, Tetsusi; Kaneda, Kazufumi; Chayama, Kazuaki

    2016-03-01

    It is necessary to establish cost-effective examinations and treatments for diminutive colorectal tumors that consider the treatment risk and surveillance interval after treatment. The Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) committee of the American Society for Gastrointestinal Endoscopy published a statement recommending the establishment of endoscopic techniques that practice the resect and discard strategy. The aims of this study were to evaluate whether our newly developed real-time image recognition system can predict histologic diagnoses of colorectal lesions depicted on narrow-band imaging and to satisfy some problems with the PIVI recommendations. We enrolled 41 patients who had undergone endoscopic resection of 118 colorectal lesions (45 nonneoplastic lesions and 73 neoplastic lesions). We compared the results of real-time image recognition system analysis with that of narrow-band imaging diagnosis and evaluated the correlation between image analysis and the pathological results. Concordance between the endoscopic diagnosis and diagnosis by a real-time image recognition system with a support vector machine output value was 97.5% (115/118). Accuracy between the histologic findings of diminutive colorectal lesions (polyps) and diagnosis by a real-time image recognition system with a support vector machine output value was 93.2% (sensitivity, 93.0%; specificity, 93.3%; positive predictive value (PPV), 93.0%; and negative predictive value, 93.3%). Although further investigation is necessary to establish our computer-aided diagnosis system, this real-time image recognition system may satisfy the PIVI recommendations and be useful for predicting the histology of colorectal tumors. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  3. Systems workplace for endoscopic surgery.

    PubMed

    Irion, K M; Novak, P

    2000-01-01

    With the advent of minimally invasive surgery (MIS) a decade ago, the requirements for operating rooms (OR) and their equipment have been increased. Compared with conventional open surgery, the new endoscopic techniques require additional tools. Television systems, for video-assisted image acquisition and visualisation, including cameras, monitors and light systems, as well as insufflators, pumps, high-frequency units, lasers and motorised therapy units, are nowadays usually made available on carts during endoscopic surgery. In conjunction with a set of endoscopic instruments, these high-tech units allow new operating techniques to be performed. The benefit for patients has become clear in recent years; however, the technical complexity of OR has also increased considerably. To minimise this problem for the OR personnel, the MIS concept 'OR1' (Operating Room 1) was developed and implemented. OR1 is a fully functional and integrated multi-speciality surgical suite for MIS. The centrepieces of the OR1 are the Storz Communication Bus (SCB) and the advanced image and data archiving system (Aida) from Karl Storz, Tuttlingen, Germany. Both components allow monitoring, access and networking of the MIS equipment and other OR facilities, as well as the acquisition, storage and display of image, patient and equipment data during the endoscopic procedure. A central user interface allows efficient, simplified operation and online clinical images. Due to the system integration, the handling of complex equipment is considerably simplified, logistical procedures in the OR are improved, procedure times are shorter and, particularly noteworthy, operative risk can be reduced through simplified device operation.

  4. The role of surgeons in identifying emerging technologies for health technology assessment.

    PubMed

    Stafinski, Tania; Topfer, Leigh-Ann; Zakariasen, Ken; Menon, Devidas

    2010-04-01

    Health technology assessment (HTA) is a tool intended to help policy-makers decide which technologies to fund. However, given the proliferation of new technologies, it is not possible to undertake an HTA of each one before it becomes funded. Consequently, "horizon-scanning" processes have been developed to identify emerging technologies that are likely to have a substantial impact on clinical practice. Although the importance of physicians in the adoption of new technologies is well recognized, their role in horizon scanning in Canada has been limited. The purpose of this project was to pilot an approach to engage physicians, specifically surgeons, in provincial horizon-scanning activities. We invited 18 surgeons from Alberta's 2 medical schools to a horizon-scanning workshop to solicit their views on emerging technologies expected to impact surgical practice within the next 5 years and/or the importance of different attributes or characteristics of new technologies. Surgeons, regardless of specialty, identified developments designed to enhance existing minimally invasive surgical techniques, such as endoscopic, robotic and image-guided surgery. Several nonsurgical areas, including molecular genetics and nano technology, were also identified. Of the 13 technology attributes discussed, safety or risk, effectiveness and feasibility were rated as most important. Lastly, participating surgeons expressed an interest in becoming further involved in local HTA initiatives. Surgeons, as adopters and users of health technologies, represent an important and accessible information source for identifying emerging technologies for HTA. A more formal, ongoing relationship between the government, HTA and surgeons may help to optimize the use of HTA resources.

  5. Endoscopic detection of murine colonic dysplasia using a novel fluorescence-labeled peptide

    NASA Astrophysics Data System (ADS)

    Miller, Sharon J.; Joshi, Bishnu P.; Gaustad, Adam; Fearon, Eric R.; Wang, Thomas D.

    2011-03-01

    Current endoscopic screening does not detect all pre-malignant (dysplastic) colorectal mucosa, thus requiring the development of more sensitive, targeted techniques to improve detection. The presented work utilizes phage display to identify a novel peptide binder to colorectal dysplasia in a CPC;Apc mouse model. A wide-field, small animal endoscope capable of fluorescence excitation (450-475 nm) identified polyps via white light and also collected fluorescence images (510 nm barrier filter) of peptide binding. The peptide bound ~2-fold greater to the colonic adenomas when compared to the control peptide. We have imaged fluorescence-labeled peptide binding in vivo that is specific towards distal colonic adenomas.

  6. Results from the commissioning of a multi-modal endoscope for ultrasound and time of flight PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bugalho, Ricardo

    2015-07-01

    The EndoTOFPET-US collaboration has developed a multi-modal imaging system combining Ultrasound with Time-of-Flight Positron Emission Tomography into an endoscopic imaging device. The objective of the project is to obtain a coincidence time resolution of about 200 ps FWHM and to achieve about 1 mm spatial resolution of the PET system, while integrating all the components in a very compact detector suitable for endoscopic use. This scanner aims to be exploited for diagnostic and surgical oncology, as well as being instrumental in the clinical test of new biomarkers especially targeted for prostate and pancreatic cancer. (authors)

  7. Imaging of endoscopic cystogastrostomy in pancreatic walled-off necrosis: what the radiologist needs to know.

    PubMed

    Abou Karam, Anthony; Bagherpour, Arya; Calleros, Jesus; Laks, Shaked

    2018-04-04

    Acute pancreatitis is a frequent entity encountered by radiologists. In 2012, the Atlanta criteria were revised to help radiologists use a common nomenclature when describing acute pancreatitis and its complications. One delayed complication of acute necrotizing pancreatitis in walled-off necrosis, a collection seen at least 4 weeks after an episode of acute pancreatic necrosis and/or acute peripancreatic necrosis. Multiple treatments have been adapted in the setting of walled-off necrosis, including endoscopic cystogastrostomy. The focus of this article is to familiarize the radiologist with the imaging appearance of this procedure as well as, review the outcomes and potential complications of endoscopic cystogastrostomy.

  8. Coherent anti-Stokes Raman scattering rigid endoscope toward robot-assisted surgery.

    PubMed

    Hirose, K; Aoki, T; Furukawa, T; Fukushima, S; Niioka, H; Deguchi, S; Hashimoto, M

    2018-02-01

    Label-free visualization of nerves and nervous plexuses will improve the preservation of neurological functions in nerve-sparing robot-assisted surgery. We have developed a coherent anti-Stokes Raman scattering (CARS) rigid endoscope to distinguish nerves from other tissues during surgery. The developed endoscope, which has a tube with a diameter of 12 mm and a length of 270 mm, achieved 0.91% image distortion and 8.6% non-uniformity of CARS intensity in the whole field of view (650 μm diameter). We demonstrated CARS imaging of a rat sciatic nerve and visualization of the fine structure of nerve fibers.

  9. Measurement of motion detection of wireless capsule endoscope inside large intestine.

    PubMed

    Zhou, Mingda; Bao, Guanqun; Pahlavan, Kaveh

    2014-01-01

    Wireless Capsule Endoscope (WCE) provides a noninvasive way to inspect the entire Gastrointestinal (GI) tract, including large intestine, where intestinal diseases most likely occur. As a critical component of capsule endoscopic examination, physicians need to know the precise position of the endoscopic capsule in order to identify the position of detected intestinal diseases. Knowing how the capsule moves inside the large intestine would greatly complement the existing wireless localization systems by providing the motion information. Since the most recently released WCE can take up to 6 frames per second, it's possible to estimate the movement of the capsule by processing the successive image sequence. In this paper, a computer vision based approach without utilizing any external device is proposed to estimate the motion of WCE inside the large intestine. The proposed approach estimate the displacement and rotation of the capsule by calculating entropy and mutual information between frames using Fibonacci method. The obtained results of this approach show its stability and better performance over other existing approaches of motion measurements. Meanwhile, findings of this paper lay a foundation for motion pattern of WCEs inside the large intestine, which will benefit other medical applications.

  10. Cascade classification of endocytoscopic images of colorectal lesions for automated pathological diagnosis

    NASA Astrophysics Data System (ADS)

    Itoh, Hayato; Mori, Yuichi; Misawa, Masashi; Oda, Masahiro; Kudo, Shin-ei; Mori, Kensaku

    2018-02-01

    This paper presents a new classification method for endocytoscopic images. Endocytoscopy is a new endoscope that enables us to perform conventional endoscopic observation and ultramagnified observation of cell level. This ultramagnified views (endocytoscopic images) make possible to perform pathological diagnosis only on endo-scopic views of polyps during colonoscopy. However, endocytoscopic image diagnosis requires higher experiences for physicians. An automated pathological diagnosis system is required to prevent the overlooking of neoplastic lesions in endocytoscopy. For this purpose, we propose a new automated endocytoscopic image classification method that classifies neoplastic and non-neoplastic endocytoscopic images. This method consists of two classification steps. At the first step, we classify an input image by support vector machine. We forward the image to the second step if the confidence of the first classification is low. At the second step, we classify the forwarded image by convolutional neural network. We reject the input image if the confidence of the second classification is also low. We experimentally evaluate the classification performance of the proposed method. In this experiment, we use about 16,000 and 4,000 colorectal endocytoscopic images as training and test data, respectively. The results show that the proposed method achieves high sensitivity 93.4% with small rejection rate 9.3% even for difficult test data.

  11. Cecal intubation rates in different eras of endoscopic technological development

    PubMed Central

    Pasternak, Artur; Szura, Mirosław; Pędziwiatr, Michał; Major, Piotr; Rembiasz, Kazimierz

    2018-01-01

    Introduction Colonoscopy plays a critical role in colorectal cancer (CRC) screening and has been widely regarded as the gold standard. Cecal intubation rate (CIR) is one of the well-defined quality indicators used to assess colonoscopy. Aim To assess the impact of new technologies on the quality of colonoscopy by assessing completion rates. Material and methods This was a dual-center study at the 2nd Department of Surgery at Jagiellonian University Medical College and at the Specialist Center “Medicina” in Krakow, Poland. The CIR and cecal intubation time (CIT) in three different eras of technological advancement were determined. The study enrolled 27 463 patients who underwent colonoscopy as part of a national CRC screening program. The patients were divided into three groups: group I – 3408 patients examined between 2000 and 2003 (optical endoscopes); group II – 10 405 patients examined between 2004 and 2008 (standard electronic endoscopes); and group III – 13 650 patients examined between 2009 and 2014 (modern endoscopes). Results There were statistically significant differences in the CIR between successive eras. The CIR in group I (2000–2003) was 69.75%, in group II (2004–2008) was 92.32%, and in group III (2009–2014) was 95.17%. The mean CIT was significantly reduced in group III. Conclusions Our study shows that the technological innovation of novel endoscopy devices has a great influence on the effectiveness of the CRC screening program. The new era of endoscopic technological development has the potential to reduce examination-related patient discomfort, obviate the need for sedation and increase diagnostic yields. PMID:29643961

  12. Laryngeal High-Speed Videoendoscopy: Rationale and Recommendation for Accurate and Consistent Terminology

    PubMed Central

    Deliyski, Dimitar D.; Hillman, Robert E.

    2015-01-01

    Purpose The authors discuss the rationale behind the term laryngeal high-speed videoendoscopy to describe the application of high-speed endoscopic imaging techniques to the visualization of vocal fold vibration. Method Commentary on the advantages of using accurate and consistent terminology in the field of voice research is provided. Specific justification is described for each component of the term high-speed videoendoscopy, which is compared and contrasted with alternative terminologies in the literature. Results In addition to the ubiquitous high-speed descriptor, the term endoscopy is necessary to specify the appropriate imaging technology and distinguish among modalities such as ultrasound, magnetic resonance imaging, and nonendoscopic optical imaging. Furthermore, the term video critically indicates the electronic recording of a sequence of optical still images representing scenes in motion, in contrast to strobed images using high-speed photography and non-optical high-speed magnetic resonance imaging. High-speed videoendoscopy thus concisely describes the technology and can be appended by the desired anatomical nomenclature such as laryngeal. Conclusions Laryngeal high-speed videoendoscopy strikes a balance between conciseness and specificity when referring to the typical high-speed imaging method performed on human participants. Guidance for the creation of future terminology provides clarity and context for current and future experiments and the dissemination of results among researchers. PMID:26375398

  13. Recent technological advances in pediatric brain tumor surgery.

    PubMed

    Zebian, Bassel; Vergani, Francesco; Lavrador, José Pedro; Mukherjee, Soumya; Kitchen, William John; Stagno, Vita; Chamilos, Christos; Pettorini, Benedetta; Mallucci, Conor

    2017-01-01

    X-rays and ventriculograms were the first imaging modalities used to localize intracranial lesions including brain tumors as far back as the 1880s. Subsequent advances in preoperative radiological localization included computed tomography (CT; 1971) and MRI (1977). Since then, other imaging modalities have been developed for clinical application although none as pivotal as CT and MRI. Intraoperative technological advances include the microscope, which has allowed precise surgery under magnification and improved lighting, and the endoscope, which has improved the treatment of hydrocephalus and allowed biopsy and complete resection of intraventricular, pituitary and pineal region tumors through a minimally invasive approach. Neuronavigation, intraoperative MRI, CT and ultrasound have increased the ability of the neurosurgeon to perform safe and maximal tumor resection. This may be facilitated by the use of fluorescing agents, which help define the tumor margin, and intraoperative neurophysiological monitoring, which helps identify and protect eloquent brain.

  14. A video wireless capsule endoscopy system powered wirelessly: design, analysis and experiment

    NASA Astrophysics Data System (ADS)

    Pan, Guobing; Xin, Wenhui; Yan, Guozheng; Chen, Jiaoliao

    2011-06-01

    Wireless capsule endoscopy (WCE), as a relatively new technology, has brought about a revolution in the diagnosis of gastrointestinal (GI) tract diseases. However, the existing WCE systems are not widely applied in clinic because of the low frame rate and low image resolution. A video WCE system based on a wireless power supply is developed in this paper. This WCE system consists of a video capsule endoscope (CE), a wireless power transmission device, a receiving box and an image processing station. Powered wirelessly, the video CE has the abilities of imaging the GI tract and transmitting the images wirelessly at a frame rate of 30 frames per second (f/s). A mathematical prototype was built to analyze the power transmission system, and some experiments were performed to test the capability of energy transferring. The results showed that the wireless electric power supply system had the ability to transfer more than 136 mW power, which was enough for the working of a video CE. In in vitro experiments, the video CE produced clear images of the small intestine of a pig with the resolution of 320 × 240, and transmitted NTSC format video outside the body. Because of the wireless power supply, the video WCE system with high frame rate and high resolution becomes feasible, and provides a novel solution for the diagnosis of the GI tract in clinic.

  15. The role of surgeons in identifying emerging technologies for health technology assessment

    PubMed Central

    Stafinski, Tania; Topfer, Leigh-Ann; Zakariasen, Ken; Menon, Devidas

    2010-01-01

    Background Health technology assessment (HTA) is a tool intended to help policy-makers decide which technologies to fund. However, given the proliferation of new technologies, it is not possible to undertake an HTA of each one before it becomes funded. Consequently, “horizon-scanning” processes have been developed to identify emerging technologies that are likely to have a substantial impact on clinical practice. Although the importance of physicians in the adoption of new technologies is well recognized, their role in horizon scanning in Canada has been limited. The purpose of this project was to pilot an approach to engage physicians, specifically surgeons, in provincial horizon-scanning activities. Methods We invited 18 surgeons from Alberta’s 2 medical schools to a horizon-scanning workshop to solicit their views on emerging technologies expected to impact surgical practice within the next 5 years and/or the importance of different attributes or characteristics of new technologies. Results Surgeons, regardless of specialty, identified developments designed to enhance existing minimally invasive surgical techniques, such as endoscopic, robotic and image-guided surgery. Several nonsurgical areas, including molecular genetics and nanotechnology, were also identified. Of the 13 technology attributes discussed, safety or risk, effectiveness and feasibility were rated as most important. Lastly, participating surgeons expressed an interest in becoming further involved in local HTA initiatives. Conclusion Surgeons, as adopters and users of health technologies, represent an important and accessible information source for identifying emerging technologies for HTA. A more formal, ongoing relationship between the government, HTA and surgeons may help to optimize the use of HTA resources. PMID:20334740

  16. Constructing spherical panoramas of a bladder phantom from endoscopic video using bundle adjustment

    NASA Astrophysics Data System (ADS)

    Soper, Timothy D.; Chandler, John E.; Porter, Michael P.; Seibel, Eric J.

    2011-03-01

    The high recurrence rate of bladder cancer requires patients to undergo frequent surveillance screenings over their lifetime following initial diagnosis and resection. Our laboratory is developing panoramic stitching software that would compile several minutes of cystoscopic video into a single panoramic image, covering the entire bladder, for review by an urolgist at a later time or remote location. Global alignment of video frames is achieved by using a bundle adjuster that simultaneously recovers both the 3D structure of the bladder as well as the scope motion using only the video frames as input. The result of the algorithm is a complete 360° spherical panorama of the outer surface. The details of the software algorithms are presented here along with results from both a virtual cystoscopy as well from real endoscopic imaging of a bladder phantom. The software successfully stitched several hundred video frames into a single panoramic with subpixel accuracy and with no knowledge of the intrinsic camera properties, such as focal length and radial distortion. In the discussion, we outline future work in development of the software as well as identifying factors pertinent to clinical translation of this technology.

  17. A clinical pilot study of a modular video-CT augmentation system for image-guided skull base surgery

    NASA Astrophysics Data System (ADS)

    Liu, Wen P.; Mirota, Daniel J.; Uneri, Ali; Otake, Yoshito; Hager, Gregory; Reh, Douglas D.; Ishii, Masaru; Gallia, Gary L.; Siewerdsen, Jeffrey H.

    2012-02-01

    Augmentation of endoscopic video with preoperative or intraoperative image data [e.g., planning data and/or anatomical segmentations defined in computed tomography (CT) and magnetic resonance (MR)], can improve navigation, spatial orientation, confidence, and tissue resection in skull base surgery, especially with respect to critical neurovascular structures that may be difficult to visualize in the video scene. This paper presents the engineering and evaluation of a video augmentation system for endoscopic skull base surgery translated to use in a clinical study. Extension of previous research yielded a practical system with a modular design that can be applied to other endoscopic surgeries, including orthopedic, abdominal, and thoracic procedures. A clinical pilot study is underway to assess feasibility and benefit to surgical performance by overlaying CT or MR planning data in realtime, high-definition endoscopic video. Preoperative planning included segmentation of the carotid arteries, optic nerves, and surgical target volume (e.g., tumor). An automated camera calibration process was developed that demonstrates mean re-projection accuracy (0.7+/-0.3) pixels and mean target registration error of (2.3+/-1.5) mm. An IRB-approved clinical study involving fifteen patients undergoing skull base tumor surgery is underway in which each surgery includes the experimental video-CT system deployed in parallel to the standard-of-care (unaugmented) video display. Questionnaires distributed to one neurosurgeon and two otolaryngologists are used to assess primary outcome measures regarding the benefit to surgical confidence in localizing critical structures and targets by means of video overlay during surgical approach, resection, and reconstruction.

  18. Image-based tracking of the suturing needle during laparoscopic interventions

    NASA Astrophysics Data System (ADS)

    Speidel, S.; Kroehnert, A.; Bodenstedt, S.; Kenngott, H.; Müller-Stich, B.; Dillmann, R.

    2015-03-01

    One of the most complex and difficult tasks for surgeons during minimally invasive interventions is suturing. A prerequisite to assist the suturing process is the tracking of the needle. The endoscopic images provide a rich source of information which can be used for needle tracking. In this paper, we present an image-based method for markerless needle tracking. The method uses a color-based and geometry-based segmentation to detect the needle. Once an initial needle detection is obtained, a region of interest enclosing the extracted needle contour is passed on to a reduced segmentation. It is evaluated with in vivo images from da Vinci interventions.

  19. Homographic Patch Feature Transform: A Robustness Registration for Gastroscopic Surgery.

    PubMed

    Hu, Weiling; Zhang, Xu; Wang, Bin; Liu, Jiquan; Duan, Huilong; Dai, Ning; Si, Jianmin

    2016-01-01

    Image registration is a key component of computer assistance in image guided surgery, and it is a challenging topic in endoscopic environments. In this study, we present a method for image registration named Homographic Patch Feature Transform (HPFT) to match gastroscopic images. HPFT can be used for tracking lesions and augmenting reality applications during gastroscopy. Furthermore, an overall evaluation scheme is proposed to validate the precision, robustness and uniformity of the registration results, which provides a standard for rejection of false matching pairs from corresponding results. Finally, HPFT is applied for processing in vivo gastroscopic data. The experimental results show that HPFT has stable performance in gastroscopic applications.

  20. TECHNOLOGICAL INNOVATION IN NEUROSURGERY: A QUANTITATIVE STUDY

    PubMed Central

    Marcus, Hani J; Hughes-Hallett, Archie; Kwasnicki, Richard M; Darzi, Ara; Yang, Guang-Zhong; Nandi, Dipankar

    2015-01-01

    Object Technological innovation within healthcare may be defined as the introduction of a new technology that initiates a change in clinical practice. Neurosurgery is a particularly technologically intensive surgical discipline, and new technologies have preceded many of the major advances in operative neurosurgical technique. The aim of the present study was to quantitatively evaluate technological innovation in neurosurgery using patents and peer-reviewed publications as metrics of technology development and clinical translation respectively. Methods A patent database was searched between 1960 and 2010 using the search terms “neurosurgeon” OR “neurosurgical” OR “neurosurgery”. The top 50 performing patent codes were then grouped into technology clusters. Patent and publication growth curves were then generated for these technology clusters. A top performing technology cluster was then selected as an exemplar for more detailed analysis of individual patents. Results In all, 11,672 patents and 208,203 publications relating to neurosurgery were identified. The top performing technology clusters over the 50 years were: image guidance devices, clinical neurophysiology devices, neuromodulation devices, operating microscopes and endoscopes. Image guidance and neuromodulation devices demonstrated a highly correlated rapid rise in patents and publications, suggesting they are areas of technology expansion. In-depth analysis of neuromodulation patents revealed that the majority of high performing patents were related to Deep Brain Stimulation (DBS). Conclusions Patent and publication data may be used to quantitatively evaluate technological innovation in neurosurgery. PMID:25699414

  1. Robotic Surgery

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The Automated Endoscopic System for Optimal Positioning, or AESOP, was developed by Computer Motion, Inc. under a SBIR contract from the Jet Propulsion Lab. AESOP is a robotic endoscopic positioning system used to control the motion of a camera during endoscopic surgery. The camera, which is mounted at the end of a robotic arm, previously had to be held in place by the surgical staff. With AESOP the robotic arm can make more precise and consistent movements. AESOP is also voice controlled by the surgeon. It is hoped that this technology can be used in space repair missions which require precision beyond human dexterity. A new generation of the same technology entitled the ZEUS Robotic Surgical System can make endoscopic procedures even more successful. ZEUS allows the surgeon control various instruments in its robotic arms, allowing for the precision the procedure requires.

  2. Hysteroscopic simulator for training and educational purposes.

    PubMed

    Lim, Fabian; Brown, Ian; McColl, Ryan; Seligman, Cory; Alsaraira, Amer

    2006-01-01

    Hysteroscopy is an extensively popular option in evaluating and treating women with infertility. The procedure utilizes an endoscope, inserted through the vagina and cervix to examine the intra-uterine cavity via a monitor. The difficulty of hysteroscopy from the surgeon's perspective is the visual spatial perception of interpreting 3D images on a 2D monitor, and the associated psychomotor skills in overcoming the fulcrum-effect. Despite the widespread use of this procedure, current qualified hysteroscopy surgeons have not been trained the fundamentals through an organized curriculum. The emergence of virtual reality as an educational tool for this procedure, and for other endoscopic procedures, has undoubtedly raised interests. The ultimate objective is for the inclusion of virtual reality training as a mandatory component for gynecological endoscopic training. Part of this process involves the design of a simulator, encompassing the technical difficulties and complications associated with the procedure. The proposed research examines fundamental hysteroscopic factors as well as current training and accreditation norms, and proposes a hysteroscopic simulator design that is suitable for educating and training.

  3. First Application of 7-T Magnetic Resonance Imaging in Endoscopic Endonasal Surgery of Skull Base Tumors.

    PubMed

    Barrett, Thomas F; Dyvorne, Hadrien A; Padormo, Francesco; Pawha, Puneet S; Delman, Bradley N; Shrivastava, Raj K; Balchandani, Priti

    2017-07-01

    Successful endoscopic endonasal surgery for the resection of skull base tumors is reliant on preoperative imaging to delineate pathology from the surrounding anatomy. The increased signal-to-noise ratio afforded by 7-T MRI can be used to increase spatial and contrast resolution, which may lend itself to improved imaging of the skull base. In this study, we apply a 7-T imaging protocol to patients with skull base tumors and compare the images with clinical standard of care. Images were acquired at 7 T on 11 patients with skull base lesions. Two neuroradiologists evaluated clinical 1.5-, 3-, and 7-T scans for detection of intracavernous cranial nerves and internal carotid artery (ICA) branches. Detection rates were compared. Images were used for surgical planning and uploaded to a neuronavigation platform and used to guide surgery. Image analysis yielded improved detection rates of cranial nerves and ICA branches at 7 T. The 7-T images were successfully incorporated into preoperative planning and intraoperative neuronavigation. Our study represents the first application of 7-T MRI to the full neurosurgical workflow for endoscopic endonasal surgery. We detected higher rates of cranial nerves and ICA branches at 7-T MRI compared with 3- and 1.5-T MRI, and found that integration of 7 T into surgical planning and guidance was feasible. These results suggest a potential for 7-T MRI to reduce surgical complications. Future studies comparing standardized 7-, 3-, and 1.5-T MRI protocols in a larger number of patients are warranted to determine the relative benefit of 7-T MRI for endonasal endoscopic surgical efficacy. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. First Application of 7T Magnetic Resonance Imaging in Endoscopic Endonasal Surgery of Skull Base Tumors

    PubMed Central

    Barrett, Thomas F; Dyvorne, Hadrien A; Padormo, Francesco; Pawha, Puneet S; Delman, Bradley N; Shrivastava, Raj K; Balchandani, Priti

    2018-01-01

    Background Successful endoscopic endonasal surgery for the resection of skull base tumors is reliant on preoperative imaging to delineate pathology from the surrounding anatomy. The increased signal-to-noise ratio afforded by 7T MRI can be used to increase spatial and contrast resolution, which may lend itself to improved imaging of skull base. In this study, we apply a 7T imaging protocol to patients with skull base tumors and compare the images to clinical standard of care. Methods Images were acquired at 7T on 11 patients with skull base lesions. Two neuroradiologists evaluated clinical 1.5T, 3T, and 7T scans for detection of intracavernous cranial nerves and ICA branches. Detection rates were compared. Images were utilized for surgical planning and uploaded to a neuronavigation platform and used to guide surgery. Results Image analysis yielded improved detection rates of cranial nerves and ICA branches at 7T. 7T images were successfully incorporated into preoperative planning and intraoperative neuronavigation. Conclusion Our study represents the first application of 7T MRI to the full neurosurgical workflow for endoscopic endonasal surgery. We detected higher rates of cranial nerves and ICA branches at 7T MRI compared to 3T and 1.5 T, and found that integration of 7T into surgical planning and guidance was feasible. These results suggest a potential for 7T MRI to reduce surgical complications. Future studies comparing standardized 7T, 3T, and 1.5 T MRI protocols in a larger number of patients are warranted to determine the relative benefit of 7T MRI for endonasal endoscopic surgical efficacy. PMID:28359922

  5. An ultra-low-power image compressor for capsule endoscope.

    PubMed

    Lin, Meng-Chun; Dung, Lan-Rong; Weng, Ping-Kuo

    2006-02-25

    Gastrointestinal (GI) endoscopy has been popularly applied for the diagnosis of diseases of the alimentary canal including Crohn's Disease, Celiac disease and other malabsorption disorders, benign and malignant tumors of the small intestine, vascular disorders and medication related small bowel injury. The wireless capsule endoscope has been successfully utilized to diagnose diseases of the small intestine and alleviate the discomfort and pain of patients. However, the resolution of demosaicked image is still low, and some interesting spots may be unintentionally omitted. Especially, the images will be severely distorted when physicians zoom images in for detailed diagnosis. Increasing resolution may cause significant power consumption in RF transmitter; hence, image compression is necessary for saving the power dissipation of RF transmitter. To overcome this drawback, we have been developing a new capsule endoscope, called GICam. We developed an ultra-low-power image compression processor for capsule endoscope or swallowable imaging capsules. In applications of capsule endoscopy, it is imperative to consider battery life/performance trade-offs. Applying state-of-the-art video compression techniques may significantly reduce the image bit rate by their high compression ratio, but they all require intensive computation and consume much battery power. There are many fast compression algorithms for reducing computation load; however, they may result in distortion of the original image, which is not good for use in the medical care. Thus, this paper will first simplify traditional video compression algorithms and propose a scalable compression architecture. As the result, the developed video compressor only costs 31 K gates at 2 frames per second, consumes 14.92 mW, and reduces the video size by 75% at least.

  6. Dual-Channel Endoscopic Indocyanine Green Fluorescence Angiography for Clipping of Cerebral Aneurysms.

    PubMed

    Cho, Won-Sang; Kim, Jeong Eun; Kang, Hyun-Seung; Ha, Eun Jin; Jung, Minwoong; Lee, Choonghee; Shin, Il Hyung; Kang, Uk

    2017-04-01

    Neuroendoscopy is useful for assessing status of perforators, parent arteries, and aneurysms beyond the straight line of microscopic view during aneurysm clipping. We aimed to evaluate the clinical usefulness of our endoscopic indocyanine green angiography (ICGA) system, which can simultaneously display visible light and indocyanine green fluorescent images. Surgical clipping of 16 unruptured aneurysms in 10 patients was performed via the keyhole approach. Using our endoscopic ICGA and commercial microscopic ICGA systems, we prospectively compared 10 targeted cerebral aneurysms at the posterior communicating (n = 4) and anterior choroidal (n = 6) arteries. Microscopic ICGA and endoscopic ICGA were feasible during surgery. Microscopic ICGA displayed 50% of branch orifices, 100% of branch trunks, and 20% of exact clip positions, whereas endoscopic ICGA showed 100% of these. Based on endoscopic ICGA findings such as incomplete clipping and compromise of parent arteries or branches, clips were repositioned in 2 cases, and additional clips were applied in 2 cases. Complete occlusion and residual neck states were achieved in 6 and 4 aneurysms after surgery. There were no neurologic deficits within 3 months after surgery except for frontalis palsy and anosmia in each patient. The endoscopic ICGA system with dual imaging of visible light and indocyanine green fluorescence was very useful for assessing geometry of aneurysms and surrounding vessels before clipping and for evaluating completeness of clip position after clipping. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Biophotonic endoscopy: a review of clinical research techniques for optical imaging and sensing of early gastrointestinal cancer

    PubMed Central

    Coda, Sergio; Siersema, Peter D.; Stamp, Gordon W. H.; Thillainayagam, Andrew V.

    2015-01-01

    Detection, characterization, and staging constitute the fundamental elements in the endoscopic diagnosis of gastrointestinal diseases, but histology still remains the diagnostic gold standard. New developments in endoscopic techniques may challenge histopathology in the near future. An ideal endoscopic technique should combine a wide-field, “red flag” screening technique with an optical contrast or microscopy method for characterization and staging, all simultaneously available during the procedure. In theory, biophotonic advances have the potential to unite these elements to allow in vivo “optical biopsy.” These techniques may ultimately offer the potential to increase the rates of detection of high risk lesions and the ability to target biopsies and resections, and so reduce the need for biopsy, costs, and uncertainty for patients. However, their utility and sensitivity in clinical practice must be evaluated against those of conventional histopathology. This review describes some of the most recent applications of biophotonics in endoscopic optical imaging and metrology, along with their fundamental principles and the clinical experience that has been acquired in their deployment as tools for the endoscopist. Particular emphasis has been placed on translational label-free optical techniques, such as fluorescence spectroscopy, fluorescence lifetime imaging microscopy (FLIM), two-photon and multi-photon microscopy, second harmonic generation (SHG) and third harmonic generation (THG) imaging, optical coherence tomography (OCT), diffuse reflectance, Raman spectroscopy, and molecular imaging. PMID:26528489

  8. Endoscopic Devices for Obesity.

    PubMed

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.

  9. Clinical relevance of endoscopic assessment of inflammation in ulcerative colitis: Can endoscopic evaluation predict outcomes?

    PubMed Central

    Mohammed, Noor; Subramanian, Venkataraman

    2016-01-01

    Ulcerative colitis (UC) is a chronic inflammatory bowel condition characterised by a relapsing and remitting course. Symptom control has been the traditional mainstay of medical treatment. It is well known that histological inflammatory activity persists despite adequate symptom control and absence of endoscopic inflammation. Current evidence suggests that presence of histological inflammation poses a greater risk of disease relapse and subsequent colorectal cancer risk. New endoscopic technologies hold promise for developing endoscopic markers of mucosal inflammation. Achieving endoscopic and histological remission appears be the future aim of medical treatments for UC. This review article aims to evaluate the use of endoscopy as a tool in assessment of mucosal inflammation UC and its correlation with disease outcomes. PMID:27895420

  10. Miniaturized Fourier-plane fiber scanner for OCT endoscopy

    NASA Astrophysics Data System (ADS)

    Vilches, Sergio; Kretschmer, Simon; Ataman, Çağlar; Zappe, Hans

    2017-10-01

    A forward-looking endoscopic optical coherence tomography (OCT) probe featuring a Fourier-plane fiber scanner is designed, manufactured and characterized. In contrast to common image-plane fiber scanners, the Fourier-plane scanner is a telecentric arrangement that eliminates vignetting and spatial resolution variations across the image plane. To scan the OCT beam in a spiral pattern, a tubular piezoelectric actuator is used to resonate an optical fiber bearing a collimating GRIN lens at its tip. The free-end of the GRIN lens sits at the back focal plane of an objective lens, such that its rotation replicates the beam angles in the collimated region of a classical telecentric 4f optical system. Such an optical arrangement inherently has a low numerical aperture combined with a relatively large field-of-view, rendering it particularly useful for endoscopic OCT imaging. Furthermore, the optical train of the Fourier-plane scanner is shorter than that of a comparable image-plane scanner by one focal length of the objective lens, significantly shortening the final arrangement. As a result, enclosed within a 3D printed housing of 2.5 mm outer diameter and 15 mm total length, the developed probe is the most compact forward-looking endoscopic OCT imager to date. Due to its compact form factor and compatibility with real-time OCT imaging, the developed probe is also ideal for use in the working channel of flexible endoscopes as a potential optical biopsy tool.

  11. Fluoroscopy-Guided Endoscopic Removal of Foreign Bodies.

    PubMed

    Kim, Junhwan; Ahn, Ji Yong; So, Seol; Lee, Mingee; Oh, Kyunghwan; Jung, Hwoon-Yong

    2017-03-01

    In most cases of ingested foreign bodies, endoscopy is the first treatment of choice. Moreover, emergency endoscopic removal is required for sharp and pointed foreign bodies such as animal or fish bones, food boluses, and button batteries due to the increased risks of perforation, obstruction, and bleeding. Here, we presented two cases that needed emergency endoscopic removal of foreign bodies without sufficient fasting time. Foreign bodies could not be visualized by endoscopy due to food residue; therefore, fluoroscopic imaging was utilized for endoscopic removal of foreign bodies in both cases.

  12. Fluorescence-Raman Dual Modal Endoscopic System for Multiplexed Molecular Diagnostics

    NASA Astrophysics Data System (ADS)

    Jeong, Sinyoung; Kim, Yong-Il; Kang, Homan; Kim, Gunsung; Cha, Myeong Geun; Chang, Hyejin; Jung, Kyung Oh; Kim, Young-Hwa; Jun, Bong-Hyun; Hwang, Do Won; Lee, Yun-Sang; Youn, Hyewon; Lee, Yoon-Sik; Kang, Keon Wook; Lee, Dong Soo; Jeong, Dae Hong

    2015-03-01

    Optical endoscopic imaging, which was recently equipped with bioluminescence, fluorescence, and Raman scattering, allows minimally invasive real-time detection of pathologies on the surface of hollow organs. To characterize pathologic lesions in a multiplexed way, we developed a dual modal fluorescence-Raman endomicroscopic system (FRES), which used fluorescence and surface-enhanced Raman scattering nanoprobes (F-SERS dots). Real-time, in vivo, and multiple target detection of a specific cancer was successful, based on the fast imaging capability of fluorescence signals and the multiplex capability of simultaneously detected SERS signals using an optical fiber bundle for intraoperative endoscopic system. Human epidermal growth factor receptor 2 (HER2) and epidermal growth factor receptor (EGFR) on the breast cancer xenografts in a mouse orthotopic model were successfully detected in a multiplexed way, illustrating the potential of FRES as a molecular diagnostic instrument that enables real-time tumor characterization of receptors during routine endoscopic procedures.

  13. 3D endoscopic imaging using structured illumination technique (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Le, Hanh N. D.; Nguyen, Hieu; Wang, Zhaoyang; Kang, Jin U.

    2017-02-01

    Surgeons have been increasingly relying on minimally invasive surgical guidance techniques not only to reduce surgical trauma but also to achieve accurate and objective surgical risk evaluations. A typical minimally invasive surgical guidance system provides visual assistance in two-dimensional anatomy and pathology of internal organ within a limited field of view. In this work, we propose and implement a structure illumination endoscope to provide a simple, inexpensive 3D endoscopic imaging to conduct high resolution 3D imagery for use in surgical guidance system. The system is calibrated and validated for quantitative depth measurement in both calibrated target and human subject. The system exhibits a depth of field of 20 mm, depth resolution of 0.2mm and a relative accuracy of 0.1%. The demonstrated setup affirms the feasibility of using the structured illumination endoscope for depth quantization and assisting medical diagnostic assessments

  14. Simple fibre based dispersion management for two-photon excited fluorescence imaging through an endoscope

    NASA Astrophysics Data System (ADS)

    Dimopoulos, Konstantinos; Marti, Dominik; Andersen, Peter E.

    2018-02-01

    We want to implement two-photon excitation fluorescence microscopy (TPEFM) into endoscopes, since TPEFM can provide relevant biomarkers for cancer staging and grading in hollow organs, endoscopically accessible through natural orifices. However, many obstacles must be overcome, among others the delivery of short laser pulses to the distal end of the endoscope. To this avail, we present imaging results using an all-fibre dispersion management scheme in a TPEFM setup. The scheme has been conceived by Jespersen et al. in 20101 and relies on the combination of a single mode fibre with normal and a higher order mode fibre with anomalous dispersion properties, fused in series using a long period grating. We show that using this fibre assembly, a simple and robust pulsed laser delivery system without any free-space optics, which is thus suitable for clinical use, can be realised.

  15. Optical design of a dual wave band catadioptric endoscope for the Joint European Torus

    NASA Astrophysics Data System (ADS)

    Greco, Vincenzo; Maddaluno, Giorgio

    2004-02-01

    In this paper we describe the optical design of a catadioptric endoscope for the Joint European Torus (JET). The JET is the flagship experiment in the European nuclear fusion research programme. It is a large tokamak (Russian acronym for "toroidal magnetic chamber") system located at Culham (UK). At the centre of this machine there is a toroidal (ring - shaped) vacuum vessel where the plasma is confined by magnetic fields. The endoscope explores in two wave bands (4.2 μm - 4.4 μm and 0.6 μm - 0.7 μm) an entire cross section of the vacuum vessel. It then creates for each wave band an image onto a separate area image sensor, located 5500 mm away from the plasma behind a concrete shield. The endoscope performs two different functions namely: infrared thermography on plasma facing components and in vessel inspection.

  16. [Breast cancer metastases to the stomach and colon: two case reports].

    PubMed

    Pulanić, Roland; Jelavić, Marko; Premuzić, Marina; Opacić, Milorad; Jakic-Razumović, Jasminka; Padovan-Stern, Ranka; Vrbanec, Damir

    2012-01-01

    Summary. Breast cancer has a high potential for metastasis, usually to the lungs, bones, liver and lymph nodes. Metastases in the holow organs of the digestive system are rare and mainly affectes the stomach and colon. They are characterized by very different clinical and radiological manifestations. We have warned that the initial unrecognized breast cancer can appear as a primary tumor of the stomach and colon, and onlya histopathological analysis reveales that it is a metastatic breast cancer. Metastases to the stomach or intestine involve deep layer of the mucosa and pathohistological findings of standard biopsy sample can be falsely negative, despite positive imaging technique (abdominal ultrasound and MSCT, endoscopic ultrasound) that indicate the tumor process. That's,why we emphasize the importance of endoscopic mucosal resection in the detection of malignant process of deeper layers of the gastric mucosa and deep intestinal mucosal biopsies with postoperative analysis of its walls.

  17. Endoscopic ultrasound-guided techniques for diagnosing pancreatic mass lesions: Can we do better?

    PubMed Central

    Storm, Andrew C; Lee, Linda S

    2016-01-01

    The diagnostic approach to a possible pancreatic mass lesion relies first upon various non-invasive imaging modalities, including computed tomography, ultrasound, and magnetic resonance imaging techniques. Once a suspect lesion has been identified, tissue acquisition for characterization of the lesion is often paramount in developing an individualized therapeutic approach. Given the high prevalence and mortality associated with pancreatic cancer, an ideal approach to diagnosing pancreatic mass lesions would be safe, highly sensitive, and reproducible across various practice settings. Tools, in addition to radiologic imaging, currently employed in the initial evaluation of a patient with a pancreatic mass lesion include serum tumor markers, endoscopic retrograde cholangiopancreatography, and endoscopic ultrasound-guided fine needle aspiration (EUS-FNA). EUS-FNA has grown to become the gold standard in tissue diagnosis of pancreatic lesions. PMID:27818584

  18. Fluorescence endoscopy using fiber speckle illumination

    NASA Astrophysics Data System (ADS)

    Nakano, Shuhei; Katagiri, Takashi; Matsuura, Yuji

    2018-02-01

    An endoscopic fluorescence imaging system based on fiber speckle illumination is proposed. In this system, a multimode fiber for transmission of excitation laser light and collection of fluorescence is inserted into a conventional flexible endoscope. Since the excitation laser light has random speckle structure, one can detect fluorescence signal corresponding to the irradiation pattern if the sample contains fluorophores. The irradiation pattern can be captured by the endoscope camera when the excitation wavelength is within the sensitivity range of the camera. By performing multiple measurements while changing the irradiation pattern, a fluorescence image is reconstructed by solving a norm minimization problem. The principle of our method was experimentally demonstrated. A 2048 pixels image of quantum dots coated on a frosted glass was successfully reconstructed by 32 measurements. We also confirmed that our method can be applied on biological tissues.

  19. Confocal endomicroscopy of the larynx

    NASA Astrophysics Data System (ADS)

    Just, T.; Wiechmann, T.; Stachs, O.; Stave, J.; Guthoff, R.; Hüttmann, G.; Pau, H. W.

    2012-02-01

    Beside the good image quality with the confocal laser scanning microscope (HRTII) and the Rostock Cornea Module (RCM), this technology can not be used to investigate the human larynx in vivo. To accomplish this, a rigid custom-made endoscope (KARL STORZ GmbH & Co. KG; Tuttlingen Germany) was developed. A connector was developed to connect the scanner head of the HRTII to the rigid endoscope. With the connector, the starting plane can be set manually. To achieve optical sectioning of the laryngeal tissue (80 μm per volume scan), the scanning mechanism of the HRTII needs to be activated using a foot switch. The devices consisting of the endoscope, HRTII, and the connector supply images of 400 x 400 μm and reach average penetration depths of 100-300 μm (λ/4 plate of the scanner head of the HRTII was removed). The lateral and axial resolutions are about 1-2 μm and 2 μm, respectively. In vivo rigid confocal endoscopy is demonstrated with an acquisition time for a volume scan of 6 s. The aim of this study was to differentiate pre-malignant laryngeal lesions from micro-invasive carcinoma of the larynx. 22 patients with suspicious lesions of the true vocal cords were included. This pilot study clearly demonstrates the possibility to detect dysplastic cells close to the basal cell layer and within the subepithelial space in lesions with small leukoplakia (thin keratin layer). These findings may have an impact on microlaryngoscopy to improve the precision for biopsy and on microlaryngoscopic laser surgery of the larynx to identify the margins of the pre-malignant lesion.

  20. The effect of augmented real-time image guidance on task workload during endoscopic sinus surgery.

    PubMed

    Dixon, Benjamin J; Chan, Harley; Daly, Michael J; Vescan, Allan D; Witterick, Ian J; Irish, Jonathan C

    2012-01-01

    Due to proximity to critical structures, the need for spatial awareness during endoscopic sinus surgery (ESS) is essential. We have developed an augmented, real-time image-guided surgery (ART-IGS) system that provides live navigational data and proximity alerts to the operating surgeon during ablation. We wished to test the hypothesis that task workload would be reduced when using this technology. A trial involved 8 otolaryngology residents and fellows performing ESS on cadaveric specimens; 1 side in a conventional method (control) and 1 side with ART-IGS. After computed tomography scanning, anatomical contouring, and registration of the head, a three-dimensional (3D) virtual endoscopic view, ablative tool tracking, and proximity alerts were enabled. Each subject completed ESS tasks and rated their workload during and after the exercise using the National Aeronautics and Space Administration (NASA) Task Load Index (TLX). A questionnaire and open feedback interview were completed after the procedure. There was a significant reduction in mental demand, temporal demand, effort, and frustration when using the ART-IGS system in comparison to the control (p < 0.02). Perceived performance was increased (p = 0.02). Most subjects agreed that the system was sufficiently accurate, caused minimal interruption, and increased confidence. Optical tracking line-of-sight issues were frequently cited as the main limitation early in the study; however, this was largely resolved. ART-IGS reduces task workload for trainees performing ESS. Live navigation and alert zones may be a valuable intraoperative teaching aid. Copyright © 2012 American Rhinologic Society-American Academy of Otolaryngic Allergy, LLC.

  1. Design of wormlike automated robotic endoscope: dynamic interaction between endoscopic balloon and surrounding tissues.

    PubMed

    Poon, Carmen C Y; Leung, Billy; Chan, Cecilia K W; Lau, James Y W; Chiu, Philip W Y

    2016-02-01

    The current design of capsule endoscope is limited by the inability to control the motion within gastrointestinal tract. The rising incidence of gastrointestinal cancers urged improvement in the method of screening endoscopy. This preclinical study aimed to design and develop a novel locomotive module for capsule endoscope. We investigated the feasibility and physical properties of this newly designed caterpillar-like capsule endoscope with a view to enhancing screening endoscopy. This study consisted of preclinical design and experimental testing on the feasibility of automated locomotion for a prototype caterpillar endoscope. The movement was examined first in the PVC tube and then in porcine intestine. The image captured was transmitted to handheld device to confirm the control of movement. The balloon pressure and volume as well as the contact force between the balloon and surroundings were measured when the balloon was inflated inside (1) a hard PVC tube, (2) a soft PVC tube, (3) muscular sites of porcine colons and (4) less muscular sites of porcine colons. The prototype caterpillar endoscope was able to move inward and backward within the PVC tubing and porcine intestine. Images were able to be captured from the capsule endoscope attached and being observed with a handheld device. Using the onset of a contact force as indication of the buildup of the gripping force between the balloon and the lumen walls, it is concluded from the results of this study that the rate of change in balloon pressure and volume is two good estimators to optimize the inflation of the balloon. The results of this study will facilitate further refinement in the design of caterpillar robotic endoscope to move inside the GI tract.

  2. An algorithm for improving the quality of structural images of turbid media in endoscopic optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Potlov, A. Yu.; Frolov, S. V.; Proskurin, S. G.

    2018-04-01

    High-quality OCT structural images reconstruction algorithm for endoscopic optical coherence tomography of biological tissue is described. The key features of the presented algorithm are: (1) raster scanning and averaging of adjacent Ascans and pixels; (2) speckle level minimization. The described algorithm can be used in the gastroenterology, urology, gynecology, otorhinolaryngology for mucous membranes and skin diagnostics in vivo and in situ.

  3. Applications of rigid and flexible GRIN-endoscopes

    NASA Astrophysics Data System (ADS)

    Schenkl, Selma; Ehlers, Alexander; Riemann, Iris; Messerschmidt, Bernhard; Bückle, Rainer; König, Karsten

    2007-02-01

    Multiphoton autofluorescence imaging became an important technique for minimal invasive examination of cells in biological tissue. Rigid and flexible endoscopes based on gradient index lenses (GRIN-lenses) extend this minimalinvasive technique to deep lying cell layers, inner body and specimens, difficult to access. In the rigid endoscope, a GRIN-lens overcomes the limited depth range, given by the working distance of the microscope objective. The focus of the conventional laser scanning tomography is reproduced tens of millimeters in the specimen under study by the GRIN-lens (diameter 1.8 and 3 μm). We will present images of fluorescent beads, proteins cells and skin tissue, as well as first in vivo measurements on human skin. The autofluorescence signal stems from the endogenous fluorophore elastin and SHG from collagen. The flexible endoscope dispenses completely the need of a microscope next to the specimen of interest. The excitation laser pulses is delivered via a well-characterized photonic crystal fiber and subsequently focused by a newly designed GRIN-lens system. The fluorescence, also transferred by a fiber is detected by a PMT detector. We will show the excellent imaging qualities of a newly developed GRIN-lens system with high-resolution images of proteins, cells and plant tissue and give an out-look on multiphoton endoscopy.

  4. Design and validation of a near-infrared fluorescence endoscope for detection of early esophageal malignancy

    NASA Astrophysics Data System (ADS)

    Waterhouse, Dale J.; Joseph, James; Neves, André A.; di Pietro, Massimiliano; Brindle, Kevin M.; Fitzgerald, Rebecca C.; Bohndiek, Sarah E.

    2016-08-01

    Barrett's esophagus is a known precursor lesion to esophageal adenocarcinoma. In these patients, early detection of premalignant disease, known as dysplasia, allows curative minimally invasive endoscopic therapy, but is confounded by a lack of contrast in white light endoscopy. Imaging fluorescently labeled lectins applied topically to the tissue has the potential to more accurately delineate dysplasia, but tissue autofluorescence limits both sensitivity and contrast when operating in the visible region. To overcome this challenge, we synthesized near-infrared (NIR) fluorescent wheat germ agglutinin (WGA-IR800CW) and constructed a clinically translatable bimodal NIR and white light endoscope. Images of NIR and white light with a field of view of 63 deg and an image resolution of 182 μm are coregistered and the honeycomb artifact arising from the fiber bundle is removed. A minimum detectable concentration of 110 nM was determined using a dilution series of WGA-IR800CW. We demonstrated ex vivo that this system can distinguish between gastric and squamous tissue types in mouse stomachs (p=0.0005) and accurately detect WGA-IR800CW fluorescence in human esophageal resections (compared with a gold standard imaging system, rs>0.90). Based on these findings, future work will optimize the bimodal endoscopic system for clinical trials in Barrett's surveillance.

  5. Toward intravascular morphological and biochemical imaging of atherosclerosis with optical coherence tomography (OCT) and fluorescence lifetime imaging (FLIM) (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Kim, Wihan; Serafino, Michael; Walton, Brian; Jo, Javier A.; Applegate, Brian E.

    2017-02-01

    We have shown in an ex vivo human coronary artery study that the biochemical information derived from FLIM interpreted in the context of the morphological information from OCT enables a detailed classification of human coronary plaques associated with atherosclerosis. The identification of lipid-rich plaques prone to erosion or rupture and associated with sudden coronary events can impact current clinical practice as well as future development of targeted therapies for "vulnerable" plaques. In order to realize clinical translation of intravascular OCT/FLIM we have had to develop several key technologies. A multimodal catheter endoscope capable of delivering near UV excitation for FLIM and shortwave IR for OCT has been fabricated using a ball lens design with a double clad fiber. The OCT illumination and the FLIM excitation propogate down the inner core while the large outer multimode core captures the fluorescence emission. To enable intravascular pullback imaging with this endoscope we have developed an ultra-wideband fiber optic rotary joint using the same double clad fiber. The rotary joint is based on a lensless design where two cleaved fibers, one fixed and one rotating, are brought into close proximity but not touching. Using water as the lubricant enabled operation over the near UV-shortwave IR range. Transmission over this bandwidth has been measured to be near 100% at rotational frequencies up to 147 Hz. The entire system has been assembled and placed on a mobile cart suitable for cath lab based imaging. System development, performance, and early ex vivo imaging results will be discussed.

  6. Endoscopic Therapy in Crohn's Disease: Principle, Preparation, and Technique.

    PubMed

    Chen, Min; Shen, Bo

    2015-09-01

    Stricture and fistula are common complications of Crohn's disease. Endoscopic balloon dilation and needle-knife stricturotomy has become a valid treatment option for Crohn's disease-associated strictures. Endoscopic therapy is also increasingly used in Crohn's disease-associated fistula. Preprocedural preparations, including routine laboratory testing, imaging examination, anticoagulant management, bowel cleansing and proper sedation, are essential to ensure a successful and safe endoscopic therapy. Adverse events, such as perforation and excessive bleeding, may occur during endoscopic intervention. The endoscopist should be well trained, always be cautious, anticipate for possible procedure-associated complications, be prepared for damage control during endoscopy, and have surgical backup ready. In this review, we discuss the principle, preparation, techniques of endoscopic therapy, as well as the prevention and management of endoscopic procedure-associated complications. We propose that inflammatory bowel disease endoscopy may be a part of training for "super" gastroenterology fellows, i.e., those seeking a career in advanced endoscopy or in inflammatory bowel disease.

  7. Evaluation of Analytical Modeling Functions for the Phonation Onset Process.

    PubMed

    Petermann, Simon; Kniesburges, Stefan; Ziethe, Anke; Schützenberger, Anne; Döllinger, Michael

    2016-01-01

    The human voice originates from oscillations of the vocal folds in the larynx. The duration of the voice onset (VO), called the voice onset time (VOT), is currently under investigation as a clinical indicator for correct laryngeal functionality. Different analytical approaches for computing the VOT based on endoscopic imaging were compared to determine the most reliable method to quantify automatically the transient vocal fold oscillations during VO. Transnasal endoscopic imaging in combination with a high-speed camera (8000 fps) was applied to visualize the phonation onset process. Two different definitions of VO interval were investigated. Six analytical functions were tested that approximate the envelope of the filtered or unfiltered glottal area waveform (GAW) during phonation onset. A total of 126 recordings from nine healthy males and 210 recordings from 15 healthy females were evaluated. Three criteria were analyzed to determine the most appropriate computation approach: (1) reliability of the fit function for a correct approximation of VO; (2) consistency represented by the standard deviation of VOT; and (3) accuracy of the approximation of VO. The results suggest the computation of VOT by a fourth-order polynomial approximation in the interval between 32.2 and 67.8% of the saturation amplitude of the filtered GAW.

  8. Near-infrared dental imaging using scanning fiber endoscope

    NASA Astrophysics Data System (ADS)

    Zhou, Yaxuan; Lee, Robert; Sadr, Alireza; Seibel, Eric J.

    2018-02-01

    Near-infrared (NIR) wavelength range of 1300-1500nm has the potential to outperform or augment other dental imaging modalities such as fluorescence imaging, owing to its lower scattering coefficient in enamel and trans- parency on stains and non-cariogenic plaque. However, cameras in this wavelength range are bulky and expensive, which lead to difficulties for in-vivo use and commercialization. Thus, we have proposed a new imaging device combining the scanning fiber endoscopy (SFE) and NIR imaging technology. The NIR SFE system has the advantage of miniature size (1.6 mm), flexible shaft, video frame rate (7Hz) and expandable wide field-of-view (60 degrees). Eleven extracted human teeth with or without occlusal caries were scanned by micro-computed X-ray tomography (micro-CT) to obtain 3D micro-CT images, which serve as the standard for comparison. NIR images in reflection mode were then taken on all the occlusal surfaces, using 1310nm super luminescent diode and 1460nm laser diode respectively. Qualitative comparison was performed between near-infrared im- ages and micro-CT images. Enamel demineralization in NIR appeared as areas of increased reflectivity, and distinguished from non-carious staining at the base of occlusal fissures or developmental defects on cusps. This preliminary work presented proof for practicability of combining NIR imaging technology with SFE for reliable and noninvasive dental imaging with miniaturization and low cost.

  9. Pneumoretroperitoneum and Sepsis After Transanal Endoscopic Resection of a Rectal Lateral Spreading Tumor

    PubMed Central

    Coura, Marcelo de Melo Andrade; de Almeida, Romulo Medeiros; Moreira, Natascha Mourão; de Sousa, João Batista; de Oliveira, Paulo Gonçalves

    2017-01-01

    Transanal endoscopic microsurgery is considered a safe, appropriate, and minimally invasive approach, and complications after endoscopic microsurgery are rare. We report a case of sepsis and pneumoretroperitoneum after resection of a rectal lateral spreading tumor. The patient presented with rectal mucous discharge. Colonoscopy revealed a rectal lateral spreading tumor. The patient underwent an endoscopic transanal resection of the lesion. He presented with sepsis of the abdominal focus, and imaging tests revealed pneumoretroperitoneum. A new surgical intervention was performed with a loop colostomy. Despite the existence of other reports on pneumoretroperitoneum after transanal endoscopic microsurgery, what draws attention to this case is the association with sepsis. PMID:28761873

  10. Design of illumination system in ring field capsule endoscope

    NASA Astrophysics Data System (ADS)

    Jeng, Wei-De; Mang, Ou-Yang; Chen, Yu-Ta; Wu, Ying-Yi

    2011-03-01

    This paper is researching about the illumination system in ring field capsule endoscope. It is difficult to obtain the uniform illumination on the observed object because the light intensity of LED will be changed along its angular displacement and same as luminous intensity distribution curve. So we use the optical design software which is Advanced Systems Analysis Program (ASAP) to build a photometric model for the optimal design of LED illumination system in ring field capsule endoscope. In this paper, the optimal design of illumination uniformity in the ring field capsule endoscope is from origin 0.128 up to optimum 0.603 and it would advance the image quality of ring field capsule endoscope greatly.

  11. Endoscopic probe optics for spectrally encoded confocal microscopy.

    PubMed

    Kang, Dongkyun; Carruth, Robert W; Kim, Minkyu; Schlachter, Simon C; Shishkov, Milen; Woods, Kevin; Tabatabaei, Nima; Wu, Tao; Tearney, Guillermo J

    2013-01-01

    Spectrally encoded confocal microscopy (SECM) is a form of reflectance confocal microscopy that can achieve high imaging speeds using relatively simple probe optics. Previously, the feasibility of conducting large-area SECM imaging of the esophagus in bench top setups has been demonstrated. Challenges remain, however, in translating SECM into a clinically-useable device; the tissue imaging performance should be improved, and the probe size needs to be significantly reduced so that it can fit into luminal organs of interest. In this paper, we report the development of new SECM endoscopic probe optics that addresses these challenges. A custom water-immersion aspheric singlet (NA = 0.5) was developed and used as the objective lens. The water-immersion condition was used to reduce the spherical aberrations and specular reflection from the tissue surface, which enables cellular imaging of the tissue deep below the surface. A custom collimation lens and a small-size grating were used along with the custom aspheric singlet to reduce the probe size. A dual-clad fiber was used to provide both the single- and multi- mode detection modes. The SECM probe optics was made to be 5.85 mm in diameter and 30 mm in length, which is small enough for safe and comfortable endoscopic imaging of the gastrointestinal tract. The lateral resolution was 1.8 and 2.3 µm for the single- and multi- mode detection modes, respectively, and the axial resolution 11 and 17 µm. SECM images of the swine esophageal tissue demonstrated the capability of this device to enable the visualization of characteristic cellular structural features, including basal cell nuclei and papillae, down to the imaging depth of 260 µm. These results suggest that the new SECM endoscopic probe optics will be useful for imaging large areas of the esophagus at the cellular scale in vivo.

  12. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    PubMed

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  13. Upper Nasopharyngeal Corridor for Transnasal Endoscopic Drainage of Petroclival Cholesterol Granulomas: Alternative Access in Conchal Sphenoid Patients.

    PubMed

    Turan, Nefize; Baum, Griffin R; Holland, Christopher M; Ahmad, Faiz U; Henriquez, Oswaldo A; Pradilla, Gustavo

    2016-03-01

    Background Cholesterol granulomas arising at the petrous apex can be treated via traditional open surgical, endoscopic, and endoscopic-assisted approaches. Endoscopic approaches require access to the sphenoid sinus, which is technically challenging in patients with conchal sphenoidal anatomy. Clinical Presentation A 55-year-old woman presented with intermittent headaches and tinnitus. Formal audiometry demonstrated moderately severe bilateral hearing loss. CT of the temporal bones and sella revealed a well-demarcated expansile lytic mass. MRI of the face, orbit, and neck showed a right petrous apex mass measuring 22 × 18 × 19 mm that was hyperintense on T1- and T2-weighted images without enhancement, consistent with a cholesterol granuloma. The patient had a conchal sphenoidal anatomy. Operative Technique Herein, we present an illustrative case of a low-lying petroclival cholesterol granuloma in a patient with conchal sphenoidal anatomy to describe an alternative high nasopharyngeal corridor for endoscopic transnasal transclival access. Postoperative Course Postoperatively, the patient's symptoms recovered and no complications occurred. Follow-up imaging demonstrated a patent drainage tract without evidence of recurrence. Conclusion In patients with a conchal sphenoid sinus, endoscopic transnasal transclival access can be gained using a high nasopharyngeal approach. This corridor facilitates safe access to these lesions and others in this location.

  14. Design and performance of optical endoscopes for the early detection of cancer

    NASA Astrophysics Data System (ADS)

    Keenan, Maureen Molly

    Cancer is a multistage, heterogeneous disease that develops through a series of genetic mutations. Early stage cancer is most responsive to treatment but can be the hardest to detect due to its small size, lack of definitive symptoms and potential location deep in the body. Whole body imaging methods, MRI/CT/PET, lack the necessary resolution to detect cellular level abnormalities. Optical methods, which have sufficient resolution, can be miniaturized into endoscopes, which are necessary to overcome limited penetration of light into tissue. By combining optical coherence tomography (OCT) and fluorescence imaging methods it is possible to create endoscopes sensitive to molecular and structural changes. I applied a dual-modality 2mm diameter rigid endoscope to the study of the natural history of colon cancer in a mouse model, and later applied this knowledge to the design and characterization of a 0.8 mm dual-modality flexible probe for use in human fallopian tubes. By using this endoscope, which is introduced through the natural orifice and is compatible with existing hysteroscopes, high-risk women could be screened in a procedure at a similar level of invasiveness as a colonoscopy. Therefore, the endoscope fills this gap in clinical care for women at high-risk for ovarian cancer.

  15. Optical Biopsy: A New Frontier in Endoscopic Detection and Diagnosis

    PubMed Central

    WANG, THOMAS D.; VAN DAM, JACQUES

    2007-01-01

    Endoscopic diagnosis currently relies on the ability of the operator to visualize abnormal patterns in the image created by light reflected from the mucosal surface of the gastrointestinal tract. Advances in fiber optics, light sources, detectors, and molecular biology have led to the development of several novel methods for tissue evaluation in situ. The term “optical biopsy” refers to methods that use the properties of light to enable the operator to make an instant diagnosis at endoscopy, previously possible only by using histological or cytological analysis. Promising imaging techniques include fluorescence endoscopy, optical coherence tomography, confocal microendoscopy, and molecular imaging. Point detection schemes under development include light scattering and Raman spectroscopy. Such advanced diagnostic methods go beyond standard endoscopic techniques by offering improved image resolution, contrast, and tissue penetration and providing biochemical and molecular information about mucosal disease. This review describes the basic biophysics of light-tissue interactions, assesses the strengths and weaknesses of each method, and examines clinical and preclinical evidence for each approach. PMID:15354274

  16. [Design and Implementation of Image Interpolation and Color Correction for Ultra-thin Electronic Endoscope on FPGA].

    PubMed

    Luo, Qiang; Yan, Zhuangzhi; Gu, Dongxing; Cao, Lei

    This paper proposed an image interpolation algorithm based on bilinear interpolation and a color correction algorithm based on polynomial regression on FPGA, which focused on the limited number of imaging pixels and color distortion of the ultra-thin electronic endoscope. Simulation experiment results showed that the proposed algorithm realized the real-time display of 1280 x 720@60Hz HD video, and using the X-rite color checker as standard colors, the average color difference was reduced about 30% comparing with that before color correction.

  17. Application of robotics in gastrointestinal endoscopy: A review

    PubMed Central

    Yeung, Baldwin Po Man; Chiu, Philip Wai Yan

    2016-01-01

    Multiple robotic flexible endoscope platforms have been developed based on cross specialty collaboration between engineers and medical doctors. However, significant number of these platforms have been developed for the natural orifice transluminal endoscopic surgery paradigm. Increasing amount of evidence suggest the focus of development should be placed on advanced endolumenal procedures such as endoscopic submucosal dissection instead. A thorough literature analysis was performed to assess the current status of robotic flexible endoscopic platforms designed for advanced endolumenal procedures. Current efforts are mainly focused on robotic locomotion and robotic instrument control. In the future, advances in actuation and servoing technology, optical analysis, augmented reality and wireless power transmission technology will no doubt further advance the field of robotic endoscopy. Globally, health systems have become increasingly budget conscious; widespread acceptance of robotic endoscopy will depend on careful design to ensure its delivery of a cost effective service. PMID:26855540

  18. Endoscopic Endonasal Approach for a Suprasellar Craniopharyngioma.

    PubMed

    Zenonos, Georgios A; Snyderman, Carl H; Gardner, Paul A

    2018-04-01

    Objectives  The current video presents the nuances of an endoscopic endonasal approach to a suprasellar craniopharyngioma. Design  The video analyzes the presentation, preoperative workup and imaging, surgical steps and technical nuances of the surgery, the clinical outcome, and follow-up imaging. Setting  The patient was treated by a skull base team consisting of a neurosurgeon and an ENT surgeon, at a teaching academic institution. Participants  The case refers to a 67-year-old man who presented with vision loss and headaches, and was found to have a suprasellar mass, with imaging characteristics consistent with a craniopharyngioma. Main Outcome Measures  The main outcome measures consistent of the reversal of the patient symptoms (vision loss and headaches), the recurrence-free survival based on imaging, as well as the absence of any complications. Results  The patient's vision improved after the surgery; at his last follow-up there was no evidence of recurrence on imaging. Conclusions  The endoscopic endonasal approach is safe and effective in treating suprasellar craniopharyngiomas. The link to the video can be found at: https://youtu.be/p1VXbwnAWCo .

  19. TU-AB-202-12: A Novel Method to Map Endoscopic Video to CT for Treatment Planning and Toxicity Analysis in Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, W; Yang, J; Beadle, B

    Purpose: Endoscopic examinations are routine procedures for head-and-neck cancer patients. Our goal is to develop a method to map the recorded video to CT, providing valuable information for radiotherapy treatment planning and toxicity analysis. Methods: We map video frames to CT via virtual endoscopic images rendered at the real endoscope’s CT-space coordinates. We developed two complementary methods to find these coordinates by maximizing real-to-virtual image similarity:(1)Endoscope Tracking: moves the virtual endoscope frame-by-frame until the desired frame is reached. Utilizes prior knowledge of endoscope coordinates, but sensitive to local optima. (2)Location Search: moves the virtual endoscope along possible paths through themore » volume to find the desired frame. More robust, but more computationally expensive. We tested these methods on clay phantoms with embedded markers for point mapping and protruding bolus material for contour mapping, and we assessed them qualitatively on three patient exams. For mapped points we calculated 3D-distance errors, and for mapped contours we calculated mean absolute distances (MAD) from CT contours. Results: In phantoms, Endoscope Tracking had average point error=0.66±0.50cm and average bolus MAD=0.74±0.37cm for the first 80% of each video. After that the virtual endoscope got lost, increasing these values to 4.73±1.69cm and 4.06±0.30cm. Location Search had point error=0.49±0.44cm and MAD=0.53±0.28cm. Point errors were larger where the endoscope viewed the surface at shallow angles<10 degrees (1.38±0.62cm and 1.22±0.69cm for Endoscope Tracking and Location Search, respectively). In patients, Endoscope Tracking did not make it past the nasal cavity. However, Location Search found coordinates near the correct location for 70% of test frames. Its performance was best near the epiglottis and in the nasal cavity. Conclusion: Location Search is a robust and accurate technique to map endoscopic video to CT. Endoscope Tracking is sensitive to erratic camera motion and local optima, but could be used in conjunction with anchor points found using Location Search.« less

  20. Phantom testing of a novel endoscopic OCT probe: a prelude to clinical in-vivo laryngeal use

    NASA Astrophysics Data System (ADS)

    Tatla, Taran; Pang, J. Y.; Cernat, R.; Dobre, G.; Tadrous, P. J.; Bradu, A.; Gelikonov, G.; Gelikonov, V.; Podoleanu, A. G.

    2012-12-01

    Optical coherence tomography is a novel imaging technique providing potentially high resolution tri-dimensional images of tissue microstructure up to 2-3mm deep. We present pre-clinical data from a novel miniaturised OCT probe utilised for endoscopic imaging of laryngeal mucosa. A 1300nm SS-OCT probe was passed in tandem with a flexible fibreoptic nasoendoscope into the larynx of a manikin. Ex vivo OCT images were acquired using a desktop 1300nm TD-OCT imaging system. The feasibility, robustness and safety of this set-up was demonstrated as a preliminary step to extending the use of this assembly to a clinical patient cohort with varying laryngeal pathologies.

  1. Advanced Image Enhancement Method for Distant Vessels and Structures in Capsule Endoscopy

    PubMed Central

    Pedersen, Marius

    2017-01-01

    This paper proposes an advanced method for contrast enhancement of capsule endoscopic images, with the main objective to obtain sufficient information about the vessels and structures in more distant (or darker) parts of capsule endoscopic images. The proposed method (PM) combines two algorithms for the enhancement of darker and brighter areas of capsule endoscopic images, respectively. The half-unit weighted-bilinear algorithm (HWB) proposed in our previous work is used to enhance darker areas according to the darker map content of its HSV's component V. Enhancement of brighter areas is achieved thanks to the novel threshold weighted-bilinear algorithm (TWB) developed to avoid overexposure and enlargement of specular highlight spots while preserving the hue, in such areas. The TWB performs enhancement operations following a gradual increment of the brightness of the brighter map content of its HSV's component V. In other words, the TWB decreases its averaged weights as the intensity content of the component V increases. Extensive experimental demonstrations were conducted, and, based on evaluation of the reference and PM enhanced images, a gastroenterologist (Ø.H.) concluded that the PM enhanced images were the best ones based on the information about the vessels, contrast in the images, and the view or visibility of the structures in more distant parts of the capsule endoscopy images. PMID:29225668

  2. Robot-assisted endoscope guidance versus manual endoscope guidance in functional endonasal sinus surgery (FESS).

    PubMed

    Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten

    2017-10-01

    Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.

  3. Two-photon microscopy using fiber-based nanosecond excitation.

    PubMed

    Karpf, Sebastian; Eibl, Matthias; Sauer, Benjamin; Reinholz, Fred; Hüttmann, Gereon; Huber, Robert

    2016-07-01

    Two-photon excitation fluorescence (TPEF) microscopy is a powerful technique for sensitive tissue imaging at depths of up to 1000 micrometers. However, due to the shallow penetration, for in vivo imaging of internal organs in patients beam delivery by an endoscope is crucial. Until today, this is hindered by linear and non-linear pulse broadening of the femtosecond pulses in the optical fibers of the endoscopes. Here we present an endoscope-ready, fiber-based TPEF microscope, using nanosecond pulses at low repetition rates instead of femtosecond pulses. These nanosecond pulses lack most of the problems connected with femtosecond pulses but are equally suited for TPEF imaging. We derive and demonstrate that at given cw-power the TPEF signal only depends on the duty cycle of the laser source. Due to the higher pulse energy at the same peak power we can also demonstrate single shot two-photon fluorescence lifetime measurements.

  4. Fast calibration of electromagnetically tracked oblique-viewing rigid endoscopes.

    PubMed

    Liu, Xinyang; Rice, Christina E; Shekhar, Raj

    2017-10-01

    The oblique-viewing (i.e., angled) rigid endoscope is a commonly used tool in conventional endoscopic surgeries. The relative rotation between its two moveable parts, the telescope and the camera head, creates a rotation offset between the actual and the projection of an object in the camera image. A calibration method tailored to compensate such offset is needed. We developed a fast calibration method for oblique-viewing rigid endoscopes suitable for clinical use. In contrast to prior approaches based on optical tracking, we used electromagnetic (EM) tracking as the external tracking hardware to improve compactness and practicality. Two EM sensors were mounted on the telescope and the camera head, respectively, with considerations to minimize EM tracking errors. Single-image calibration was incorporated into the method, and a sterilizable plate, laser-marked with the calibration pattern, was also developed. Furthermore, we proposed a general algorithm to estimate the rotation center in the camera image. Formulas for updating the camera matrix in terms of clockwise and counterclockwise rotations were also developed. The proposed calibration method was validated using a conventional [Formula: see text], 5-mm laparoscope. Freehand calibrations were performed using the proposed method, and the calibration time averaged 2 min and 8 s. The calibration accuracy was evaluated in a simulated clinical setting with several surgical tools present in the magnetic field of EM tracking. The root-mean-square re-projection error averaged 4.9 pixel (range 2.4-8.5 pixel, with image resolution of [Formula: see text] for rotation angles ranged from [Formula: see text] to [Formula: see text]. We developed a method for fast and accurate calibration of oblique-viewing rigid endoscopes. The method was also designed to be performed in the operating room and will therefore support clinical translation of many emerging endoscopic computer-assisted surgical systems.

  5. Early experiences of endoscopic procedures in general surgery assisted by a computer-enhanced surgical system.

    PubMed

    Hashizume, M; Shimada, M; Tomikawa, M; Ikeda, Y; Takahashi, I; Abe, R; Koga, F; Gotoh, N; Konishi, K; Maehara, S; Sugimachi, K

    2002-08-01

    We performed a variety of complete total endoscopic general surgical procedures, including colon resection, distal gastrectomy, and splenectomy, successfully with the assistance of the da Vinci computer-enhanced surgical system. The robotic system allowed us to manipulate the endoscopic instruments as effectively as during open surgery. It enhanced visualization of both the operative field and precision of the necessary techniques, as well as being less stressful for the endoscopic operating team. This technological innovation can therefore help surgeons overcome many of the difficulties associated with the endoscopic approach and thus has the potential to enable more precise, safer, and more minimally invasive surgery in the future.

  6. Transplant Image Processing Technology under Windows into the Platform Based on MiniGUI

    NASA Astrophysics Data System (ADS)

    Gan, Lan; Zhang, Xu; Lv, Wenya; Yu, Jia

    MFC has a large number of digital image processing-related API functions, object-oriented and class mechanisms which provides image processing technology strong support in Windows. But in embedded systems, image processing technology dues to the restrictions of hardware and software do not have the environment of MFC in Windows. Therefore, this paper draws on the experience of image processing technology of Windows and transplants it into MiniGUI embedded systems. The results show that MiniGUI/Embedded graphical user interface applications about image processing which used in embedded image processing system can be good results.

  7. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    PubMed

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  8. Super-achromatic microprobe for ultrahigh-resolution endoscopic OCT imaging at 800 nm (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Yuan, Wu; Alemohammad, Milad; Yu, Xiaoyun; Yu, Shaoyong; Li, Xingde

    2016-03-01

    In this paper, we report a super-achromatic microprobe made with fiber-optic ball lens to enable ultrahigh-resolution endoscopic OCT imaging. An axial resolution of ~2.4 µm (in air) can be achieved with a 7-fs Ti:Sapphire laser. The microprobe has minimal astigmatism which affords a high transverse resolution of ~5.6 µm. The miniaturized microprobe has an outer diameter of ~520 µm including the encasing metal guard and can be used to image small luminal organs. The performance of the ultrahigh-resolution OCT microprobe was demonstrated by imaging rat esophagus, guinea pig esophagus, and mouse rectum in vivo.

  9. Expanding Functionality of Commercial Optical Coherence Tomography Systems by Integrating a Custom Endoscope

    PubMed Central

    Welge, Weston A.; Barton, Jennifer K.

    2015-01-01

    Optical coherence tomography (OCT) is a useful imaging modality for detecting and monitoring diseases of the gastrointestinal tract and other tubular structures. The non-destructiveness of OCT enables time-serial studies in animal models. While turnkey commercial research OCT systems are plenty, researchers often require custom imaging probes. We describe the integration of a custom endoscope with a commercial swept-source OCT system and generalize this description to any imaging probe and OCT system. A numerical dispersion compensation method is also described. Example images demonstrate that OCT can visualize the mouse colon crypt structure and detect adenoma in vivo. PMID:26418811

  10. Capsule endoscope localization based on computer vision technique.

    PubMed

    Liu, Li; Hu, Chao; Cai, Wentao; Meng, Max Q H

    2009-01-01

    To build a new type of wireless capsule endoscope with interactive gastrointestinal tract examination, a localization and orientation system is needed for tracking 3D location and 3D orientation of the capsule movement. The magnetic localization and orientation method produces only 5 DOF, but misses the information of rotation angle along capsule's main axis. In this paper, we presented a complementary orientation approach for the capsule endoscope, and the 3D rotation can be determined by applying computer vision technique on the captured endoscopic images. The experimental results show that the complementary orientation method has good accuracy and high feasibility.

  11. In vivo imaging of pulmonary nodule and vasculature using endoscopic co-registered optical coherence tomography and autofluorescence imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Pahlevaninezhad, Hamid; Lee, Anthony; Hohert, Geoffrey; Schwartz, Carely; Shaipanich, Tawimas; Ritchie, Alexander J.; Zhang, Wei; MacAulay, Calum E.; Lam, Stephen; Lane, Pierre M.

    2016-03-01

    Peripheral lung nodules found by CT-scans are difficult to localize and biopsy bronchoscopically particularly for those ≤ 2 cm in diameter. In this work, we present the results of endoscopic co-registered optical coherence tomography and autofluorescence imaging (OCT-AFI) of normal and abnormal peripheral airways from 40 patients using 0.9 mm diameter fiber optic rotary pullback catheter. Optical coherence tomography (OCT) can visualize detailed airway morphology endoscopically in the lung periphery. Autofluorescence imaging (AFI) can visualize fluorescing tissue components such as collagen and elastin, enabling the detection of airway lesions with high sensitivity. Results indicate that AFI of abnormal airways is different from that of normal airways, suggesting that AFI can provide a sensitive visual presentation for rapidly identifying possible sites of pulmonary nodules. AFI can also rapidly visualize in vivo vascular networks using fast scanning parameters resulting in vascular-sensitive imaging with less breathing/cardiac motion artifacts compared to Doppler OCT imaging. It is known that tumor vasculature is structurally and functionally different from normal vessels. Thus, AFI can be potentially used for differentiating normal and abnormal lung vasculature for studying vascular remodeling.

  12. Prospective Clinical Trial of Robotically Assisted Endoscopic Coronary Grafting With 1-Year Follow-Up

    PubMed Central

    Prasad, Sunil M.; Ducko, Christopher T.; Stephenson, Edward R.; Chambers, Charles E.; Damiano, Ralph J.

    2001-01-01

    Objective To follow up in prospective fashion patients with coronary artery anastomoses completed endoscopically with robotic assistance. The robotic system was evaluated for safety and its effectiveness in completing microsurgical coronary anastomoses. Summary Background Data Recently there has been an interest in using robotics and computers to enhance the surgeon’s ability to perform endoscopic cardiac surgery. This interest has stemmed from the rapid advancement of technology and the desire to make cardiac surgery less invasive. Using traditional endoscopic instruments, it has not been possible to perform coronary surgery. Methods Nineteen patients underwent robotically assisted endoscopic coronary artery bypass grafting of the left internal thoracic artery (LITA) to the left anterior descending artery (LAD). Two robotic instruments and one endoscopic camera were placed through three 5-mm ports. A robotic system was used to construct the LITA–LAD anastomosis. All other required grafts were completed by conventional techniques. Results Seventeen LITA–LAD grafts (89%) had adequate intraoperative flow. The mean LITA–LAD graft flow was 38.5 ± 5 mL/min. At 8 weeks, LITA–LAD grafts were assessed by angiography and showed 100% patency with thrombolysis in myocardial infarction (TIMI) I flow. At a mean follow-up of 17 ± 4.2 months, all patients were NYHA class I and there were no adverse cardiac events. Conclusions The results from the first prospective clinical trial of robotically assisted endoscopic coronary bypass surgery in the United States showed favorable short-term outcomes with no adverse events. Robotic assistance is an enabling technology allowing the performance of endoscopic coronary anastomoses. PMID:11371730

  13. Beyond endoscopic assessment in inflammatory bowel disease: real-time histology of disease activity by non-linear multimodal imaging

    NASA Astrophysics Data System (ADS)

    Chernavskaia, Olga; Heuke, Sandro; Vieth, Michael; Friedrich, Oliver; Schürmann, Sebastian; Atreya, Raja; Stallmach, Andreas; Neurath, Markus F.; Waldner, Maximilian; Petersen, Iver; Schmitt, Michael; Bocklitz, Thomas; Popp, Jürgen

    2016-07-01

    Assessing disease activity is a prerequisite for an adequate treatment of inflammatory bowel diseases (IBD) such as Crohn’s disease and ulcerative colitis. In addition to endoscopic mucosal healing, histologic remission poses a promising end-point of IBD therapy. However, evaluating histological remission harbors the risk for complications due to the acquisition of biopsies and results in a delay of diagnosis because of tissue processing procedures. In this regard, non-linear multimodal imaging techniques might serve as an unparalleled technique that allows the real-time evaluation of microscopic IBD activity in the endoscopy unit. In this study, tissue sections were investigated using the non-linear multimodal microscopy combination of coherent anti-Stokes Raman scattering (CARS), two-photon excited auto fluorescence (TPEF) and second-harmonic generation (SHG). After the measurement a gold-standard assessment of histological indexes was carried out based on a conventional H&E stain. Subsequently, various geometry and intensity related features were extracted from the multimodal images. An optimized feature set was utilized to predict histological index levels based on a linear classifier. Based on the automated prediction, the diagnosis time interval is decreased. Therefore, non-linear multimodal imaging may provide a real-time diagnosis of IBD activity suited to assist clinical decision making within the endoscopy unit.

  14. Towards real time 2D to 3D registration for ultrasound-guided endoscopic and laparoscopic procedures.

    PubMed

    San José Estépar, Raúl; Westin, Carl-Fredrik; Vosburgh, Kirby G

    2009-11-01

    A method to register endoscopic and laparoscopic ultrasound (US) images in real time with pre-operative computed tomography (CT) data sets has been developed with the goal of improving diagnosis, biopsy guidance, and surgical interventions in the abdomen. The technique, which has the potential to operate in real time, is based on a new phase correlation technique: LEPART, which specifies the location of a plane in the CT data which best corresponds to the US image. Validation of the method was carried out using an US phantom with cyst regions and with retrospective analysis of data sets from animal model experiments. The phantom validation study shows that local translation displacements can be recovered for each US frame with a root mean squared error of 1.56 +/- 0.78 mm in less than 5 sec, using non-optimized algorithm implementations. A new method for multimodality (preoperative CT and intraoperative US endoscopic images) registration to guide endoscopic interventions was developed and found to be efficient using clinically realistic datasets. The algorithm is inherently capable of being implemented in a parallel computing system so that full real time operation appears likely.

  15. Multimedia in the informed consent process for endoscopic sinus surgery: A randomized control trial.

    PubMed

    Siu, Jennifer M; Rotenberg, Brian W; Franklin, Jason H; Sowerby, Leigh J

    2016-06-01

    To determine patient recall of specific risks associated with endoscopic sinus surgery and whether an adjunct multimedia education module is an effective patient tool in enhancing the standard informed consent process. Prospective, randomized, controlled trial. Fifty consecutive adult patients scheduled for endoscopic sinus surgery at a rhinology clinic of a tertiary care hospital were recruited for this study. Informed consent was studied by comparing the number of risks recalled when patients had a verbal discussion in conjunction with a 6-minute interactive module or the verbal discussion alone. Early recall was measured immediately following the informed consent process, and delayed recall was measured 3 to 4 weeks after patient preference details were also collected. Early risk recall in the multimedia group was significantly higher than the control group (P = .0036); however, there was no difference between the groups in delayed risk recall. Seventy-six percent of participants expressed interest in viewing the multimedia module if available online between the preoperative and procedural day. Sixty-eight percent of patients preferred having the multimedia module as an adjunct to the informed consent process as opposed to the multimedia consent process alone. There is an early improvement in overall risk recall in patients who complete an interactive multimedia module, with a clear patient preference for this method. Here we emphasize the well-known challenges of patient education and demonstrate the effectiveness of integrating technology into clinical practice in order to enhance the informed consent process. 1b Laryngoscope, 126:1273-1278, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  16. A Clinical Wide-Field Fluorescence Endoscopic Device for Molecular Imaging Demonstrating Cathepsin Protease Activity in Colon Cancer.

    PubMed

    Sensarn, Steven; Zavaleta, Cristina L; Segal, Ehud; Rogalla, Stephan; Lee, Wansik; Gambhir, Sanjiv S; Bogyo, Matthew; Contag, Christopher H

    2016-12-01

    Early and effective detection of cancers of the gastrointestinal tract will require novel molecular probes and advances in instrumentation that can reveal functional changes in dysplastic and malignant tissues. Here, we describe adaptation of a wide-field clinical fiberscope to perform wide-field fluorescence imaging while preserving its white-light capability for the purpose of providing wide-field fluorescence imaging capability to point-of-care microscopes. We developed and used a fluorescent fiberscope to detect signals from a quenched probe, BMV109, that becomes fluorescent when cleaved by, and covalently bound to, active cathepsin proteases. Cathepsins are expressed in inflammation- and tumor-associated macrophages as well as directly from tumor cells and are a promising target for cancer imaging. The fiberscope has a 1-mm outer diameter enabling validation via endoscopic exams in mice, and therefore we evaluated topically applied BMV109 for the ability to detect colon polyps in an azoxymethane-induced colon tumor model in mice. This wide-field endoscopic imaging device revealed consistent and clear fluorescence signals from BMV109 that specifically localized to the polypoid regions as opposed to the normal adjacent colon tissue (p < 0.004) in the murine colon carcinoma model. The sensitivity of detection of BMV109 with the fluorescence fiberscope suggested utility of these tools for early detection at hard-to-reach sites. The fiberscope was designed to be used in conjunction with miniature, endoscope-compatible fluorescence microscopes for dual wide-field and microscopic cancer detection.

  17. An Innovate Robotic Endoscope Guidance System for Transnasal Sinus and Skull Base Surgery: Proof of Concept.

    PubMed

    Friedrich, D T; Sommer, F; Scheithauer, M O; Greve, J; Hoffmann, T K; Schuler, P J

    2017-12-01

    Objective  Advanced transnasal sinus and skull base surgery remains a challenging discipline for head and neck surgeons. Restricted access and space for instrumentation can impede advanced interventions. Thus, we present the combination of an innovative robotic endoscope guidance system and a specific endoscope with adjustable viewing angle to facilitate transnasal surgery in a human cadaver model. Materials and Methods  The applicability of the robotic endoscope guidance system with custom foot pedal controller was tested for advanced transnasal surgery on a fresh frozen human cadaver head. Visualization was enabled using a commercially available endoscope with adjustable viewing angle (15-90 degrees). Results  Visualization and instrumentation of all paranasal sinuses, including the anterior and middle skull base, were feasible with the presented setup. Controlling the robotic endoscope guidance system was effectively precise, and the adjustable endoscope lens extended the view in the surgical field without the common change of fixed viewing angle endoscopes. Conclusion  The combination of a robotic endoscope guidance system and an advanced endoscope with adjustable viewing angle enables bimanual surgery in transnasal interventions of the paranasal sinuses and the anterior skull base in a human cadaver model. The adjustable lens allows for the abandonment of fixed-angle endoscopes, saving time and resources, without reducing the quality of imaging.

  18. A Novel Augmented Reality Navigation System for Endoscopic Sinus and Skull Base Surgery: A Feasibility Study

    PubMed Central

    Li, Liang; Yang, Jian; Chu, Yakui; Wu, Wenbo; Xue, Jin; Liang, Ping; Chen, Lei

    2016-01-01

    Objective To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery. Materials and Methods In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems. Results The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons. Conclusion The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon’s skills and knowledge, not as a substitute. PMID:26757365

  19. A Novel Augmented Reality Navigation System for Endoscopic Sinus and Skull Base Surgery: A Feasibility Study.

    PubMed

    Li, Liang; Yang, Jian; Chu, Yakui; Wu, Wenbo; Xue, Jin; Liang, Ping; Chen, Lei

    2016-01-01

    To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery. In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems. The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons. The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon's skills and knowledge, not as a substitute.

  20. Repair of Tympanic Membrane Perforations with Customized Bioprinted Ear Grafts Using Chinchilla Models.

    PubMed

    Kuo, Che-Ying; Wilson, Emmanuel; Fuson, Andrew; Gandhi, Nidhi; Monfaredi, Reza; Jenkins, Audrey; Romero, Maria; Santoro, Marco; Fisher, John P; Cleary, Kevin; Reilly, Brian

    2018-03-01

    The goal of this work is to develop an innovative method that combines bioprinting and endoscopic imaging to repair tympanic membrane perforations (TMPs). TMPs are a serious health issue because they can lead to both conductive hearing loss and repeated otitis media. TMPs occur in 3-5% of cases after ear tube placement, as well as in cases of acute otitis media (the second most common infection in pediatrics), chronic otitis media with or without cholesteatoma, or as a result of barotrauma to the ear. About 55,000 tympanoplasties, the surgery performed to reconstruct TMPs, are performed every year, and the commonly used cartilage grafting technique has a success rate between 43% and 100%. This wide variability in successful tympanoplasty indicates that the current approach relies heavily on the skill of the surgeon to carve the shield graft into the shape of the TMP, which can be extremely difficult because of the perforation's irregular shape. To this end, we hypothesized that patient specific acellular grafts can be bioprinted to repair TMPs. In vitro data demonstrated that our approach resulted in excellent wound healing responses (e.g., cell invasion and proliferations) using our bioprinted gelatin methacrylate constructs. Based on these results, we then bioprinted customized acellular grafts to treat TMP based on endoscopic imaging of the perforation and demonstrated improved TMP healing in a chinchilla study. These ear graft techniques could transform clinical practice by eliminating the need for hand-carved grafts. To our knowledge, this is the first proof of concept of using bioprinting and endoscopic imaging to fabricate customized grafts to treat tissue perforations. This technology could be transferred to other medical pathologies and be used to rapidly scan internal organs such as intestines for microperforations, brain covering (Dura mater) for determination of sites of potential cerebrospinal fluid leaks, and vascular systems to determine arterial wall damage before aneurysm rupture in strokes.

  1. Technological innovation in neurosurgery: a quantitative study.

    PubMed

    Marcus, Hani J; Hughes-Hallett, Archie; Kwasnicki, Richard M; Darzi, Ara; Yang, Guang-Zhong; Nandi, Dipankar

    2015-07-01

    Technological innovation within health care may be defined as the introduction of a new technology that initiates a change in clinical practice. Neurosurgery is a particularly technology-intensive surgical discipline, and new technologies have preceded many of the major advances in operative neurosurgical techniques. The aim of the present study was to quantitatively evaluate technological innovation in neurosurgery using patents and peer-reviewed publications as metrics of technology development and clinical translation, respectively. The authors searched a patent database for articles published between 1960 and 2010 using the Boolean search term "neurosurgeon OR neurosurgical OR neurosurgery." The top 50 performing patent codes were then grouped into technology clusters. Patent and publication growth curves were then generated for these technology clusters. A top-performing technology cluster was then selected as an exemplar for a more detailed analysis of individual patents. In all, 11,672 patents and 208,203 publications related to neurosurgery were identified. The top-performing technology clusters during these 50 years were image-guidance devices, clinical neurophysiology devices, neuromodulation devices, operating microscopes, and endoscopes. In relation to image-guidance and neuromodulation devices, the authors found a highly correlated rapid rise in the numbers of patents and publications, which suggests that these are areas of technology expansion. An in-depth analysis of neuromodulation-device patents revealed that the majority of well-performing patents were related to deep brain stimulation. Patent and publication data may be used to quantitatively evaluate technological innovation in neurosurgery.

  2. Architecture of a high-performance surgical guidance system based on C-arm cone-beam CT: software platform for technical integration and clinical translation

    NASA Astrophysics Data System (ADS)

    Uneri, Ali; Schafer, Sebastian; Mirota, Daniel; Nithiananthan, Sajendra; Otake, Yoshito; Reaungamornrat, Sureerat; Yoo, Jongheun; Stayman, J. Webster; Reh, Douglas; Gallia, Gary L.; Khanna, A. Jay; Hager, Gregory; Taylor, Russell H.; Kleinszig, Gerhard; Siewerdsen, Jeffrey H.

    2011-03-01

    Intraoperative imaging modalities are becoming more prevalent in recent years, and the need for integration of these modalities with surgical guidance is rising, creating new possibilities as well as challenges. In the context of such emerging technologies and new clinical applications, a software architecture for cone-beam CT (CBCT) guided surgery has been developed with emphasis on binding open-source surgical navigation libraries and integrating intraoperative CBCT with novel, application-specific registration and guidance technologies. The architecture design is focused on accelerating translation of task-specific technical development in a wide range of applications, including orthopaedic, head-and-neck, and thoracic surgeries. The surgical guidance system is interfaced with a prototype mobile C-arm for high-quality CBCT and through a modular software architecture, integration of different tools and devices consistent with surgical workflow in each of these applications is realized. Specific modules are developed according to the surgical task, such as: 3D-3D rigid or deformable registration of preoperative images, surgical planning data, and up-to-date CBCT images; 3D-2D registration of planning and image data in real-time fluoroscopy and/or digitally reconstructed radiographs (DRRs); compatibility with infrared, electromagnetic, and video-based trackers used individually or in hybrid arrangements; augmented overlay of image and planning data in endoscopic or in-room video; real-time "virtual fluoroscopy" computed from GPU-accelerated DRRs; and multi-modality image display. The platform aims to minimize offline data processing by exposing quantitative tools that analyze and communicate factors of geometric precision. The system was translated to preclinical phantom and cadaver studies for assessment of fiducial (FRE) and target registration error (TRE) showing sub-mm accuracy in targeting and video overlay within intraoperative CBCT. The work culminates in the development of a CBCT guidance system (reported here for the first time) that leverages the technical developments in Carm CBCT and associated technologies for realizing a high-performance system for translation to clinical studies.

  3. Ultrahigh speed endoscopic swept source optical coherence tomography using a VCSEL light source and micromotor catheter

    NASA Astrophysics Data System (ADS)

    Tsai, Tsung-Han; Ahsen, Osman O.; Lee, Hsiang-Chieh; Liang, Kaicheng; Giacomelli, Michael G.; Potsaid, Benjamin M.; Tao, Yuankai K.; Jayaraman, Vijaysekhar; Kraus, Martin F.; Hornegger, Joachim; Figueiredo, Marisa; Huang, Qin; Mashimo, Hiroshi; Cable, Alex E.; Fujimoto, James G.

    2014-03-01

    We developed an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor based imaging catheter, which provided an imaging speed of 600 kHz axial scan rate and 8 μm axial resolution in tissue. The micromotor catheter was 3.2 mm in diameter and could be introduced through the 3.7 mm accessory port of an endoscope. Imaging was performed at 400 frames per second with an 8 μm spot size using a pullback to generate volumetric data over 16 mm with a pixel spacing of 5 μm in the longitudinal direction. Three-dimensional OCT (3D-OCT) imaging was performed in patients with a cross section of pathologies undergoing standard upper and lower endoscopy at the Veterans Affairs Boston Healthcare System (VABHS). Patients with Barrett's esophagus, dysplasia, and inflammatory bowel disease were imaged. The use of distally actuated imaging catheters allowed OCT imaging with more flexibility such as volumetric imaging in the terminal ileum and the assessment of the hiatal hernia using retroflex imaging. The high rotational stability of the micromotor enabled 3D volumetric imaging with micron scale volumetric accuracy for both en face and cross-sectional imaging. The ability to perform 3D OCT imaging in the GI tract with microscopic accuracy should enable a wide range of studies to investigate the ability of OCT to detect pathology as well as assess treatment response.

  4. Two-photon autofluorescence/FLIM/SHG endoscopy to study the oral cavity and wound healing in humans (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    König, Karsten

    2016-03-01

    Monitoring the oral cavity noninvasively with superior 3D resolution is realized by clinical multiphoton tomography and high NA two-photon endoscopy without the need of additional contrast agents. The technology behind this investigation is based on nonlinear optical contrast of the multiphoton tomograph MPTflex®. Furthermore, the miniaturized GRIN endoscope was used to realize more accessibility for more demanding wound conditions in skin. The MPTflex® distinguishes autofluorescence (AF) signals from second harmonic generation (SHG) signals simultaneously. Fluorescence lifetime imaging (FLIM) based on time correlated single photon counting (TCSPC) technology offers additional information on the functional level of the intratissue fluorophores, their binding status, and the contribution of SHG signals in chronic wounds.

  5. New flexible endoscope for otologic application

    NASA Astrophysics Data System (ADS)

    Marchan, Mark L.

    1993-07-01

    Endoscopy has become an important procedure in many medical specialties. For the Otologist, however, space limitations within the ear have restricted development of endoscopic procedures. The desire for minimally invasive techniques in Otology has demonstrated itself through the work of numerous physicians who have performed procedures ranging from diagnostic inspection of the middle ear to viewing the interior of the cochlea. To assist in performing such endoscopic procedures, Xomed-Treace has developed a line of flexible fiberoptic endoscopes for use by the Otologist. These scopes combine illumination and imaging fiber bundles within a small diameter unit ranging in size from 0.8 mm to 1.2 mm. The 1.2 mm scope is produced with an angled, rigid stainless steel sheath. The 0.8 mm scope is flexible with the ability to articulate 120 degree(s) in one direction. The fiberscopes have been designed for the Otologist to produce a good resolution image while allowing ease of operation through ergonomics and consideration of the surgical anatomy.

  6. Optic Nerve Atrophy Due to Long-Standing Compression by Planum Sphenoidale Meningioma.

    PubMed

    Di Somma, Alberto; Kaen, Ariel Matias; Cárdenas Ruiz-Valdepeñas, Eugenio; Cavallo, Luigi Maria

    2018-05-01

    In this study we report an uncommon endoscopic endonasal image of an atrophic optic nerve as seen after surgical removal of a suprasellar meningioma. The peculiarity of this case is the long-lasting underestimated ocular symptomatology of the patient who reported a 15-year history of impairment of vision on her left eye. A 51-year-old woman was admitted to our hospital complaining of a 15-year history of impairment of vision on her left eye. After making serendipitously the diagnosis of a suprasellar mass, we performed endoscopic endonasal surgery. The tumor was reached from below and removed safely, without manipulation of the optic pathways. At the end of tumor removal, the impressive left optic nerve atrophy due to enduring local tumor compression was visualized. To the best of our knowledge, no endoscopic endonasal image with such features has been provided in the pertinent literature. Possibly, this contribution will help identify damaged optic nerves during endoscopic endonasal surgery. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Computer-aided decision support systems for endoscopy in the gastrointestinal tract: a review.

    PubMed

    Liedlgruber, Michael; Uhl, Andreas

    2011-01-01

    Today, medical endoscopy is a widely used procedure to inspect the inner cavities of the human body. The advent of endoscopic imaging techniques-allowing the acquisition of images or videos-created the possibility for the development of the whole new branch of computer-aided decision support systems. Such systems aim at helping physicians to identify possibly malignant abnormalities more accurately. At the beginning of this paper, we give a brief introduction to the history of endoscopy, followed by introducing the main types of endoscopes which emerged so far (flexible endoscope, wireless capsule endoscope, and confocal laser endomicroscope). We then give a brief introduction to computer-aided decision support systems specifically targeted at endoscopy in the gastrointestinal tract. Then we present general facts and figures concerning computer-aided decision support systems and summarize work specifically targeted at computer-aided decision support in the gastrointestinal tract. This summary is followed by a discussion of some common issues concerning the approaches reviewed and suggestions of possible ways to resolve them.

  8. Endoscopic surgical management of sinonasal inverted papilloma extending to frontal sinuses.

    PubMed

    Takahashi, Yukiko; Shoji, Fumi; Katori, Yukio; Hidaka, Hiroshi; Noguchi, Naoya; Abe, Yasuhiro; Kakuta, Risako Kakuta; Suzuki, Takahiro; Suzuki, Yusuke; Ohta, Nobuo; Kakehata, Seiji; Okamoto, Yoshitaka

    2016-11-10

    Sinonasal inverted papilloma has been traditionally managed with external surgical approaches. Advances in imaging guidance systems, surgical instrumentation, and intraoperative multi-visualization have led to a gradual shift from external approaches to endoscopic surgery. However, for anatomical and technical reasons, endoscopic surgery of sinonasal inverted papilloma extending to the frontal sinuses is still challenging. Here, we present our experience in endoscopic surgical management of sinonasal inverted papilloma extending to one or both frontal sinuses. We present 10 cases of sinonasal inverted papilloma extending to the frontal sinuses and successfully removed by endoscopic median drainage (Draf III procedure) under endoscopic guidance without any additional external approach. The whole cavity of the frontal sinuses was easily inspected at the end of the surgical procedure. No early or late complications were observed. No recurrence was identified after an average follow-up period of 39.5 months. Use of an endoscopic median drainage approach to manage sinonasal inverted papilloma extending to one or both frontal sinuses is feasible and seems effective.

  9. 3D surface reconstruction for laparoscopic computer-assisted interventions: comparison of state-of-the-art methods

    NASA Astrophysics Data System (ADS)

    Groch, A.; Seitel, A.; Hempel, S.; Speidel, S.; Engelbrecht, R.; Penne, J.; Höller, K.; Röhl, S.; Yung, K.; Bodenstedt, S.; Pflaum, F.; dos Santos, T. R.; Mersmann, S.; Meinzer, H.-P.; Hornegger, J.; Maier-Hein, L.

    2011-03-01

    One of the main challenges related to computer-assisted laparoscopic surgery is the accurate registration of pre-operative planning images with patient's anatomy. One popular approach for achieving this involves intraoperative 3D reconstruction of the target organ's surface with methods based on multiple view geometry. The latter, however, require robust and fast algorithms for establishing correspondences between multiple images of the same scene. Recently, the first endoscope based on Time-of-Flight (ToF) camera technique was introduced. It generates dense range images with high update rates by continuously measuring the run-time of intensity modulated light. While this approach yielded promising results in initial experiments, the endoscopic ToF camera has not yet been evaluated in the context of related work. The aim of this paper was therefore to compare its performance with different state-of-the-art surface reconstruction methods on identical objects. For this purpose, surface data from a set of porcine organs as well as organ phantoms was acquired with four different cameras: a novel Time-of-Flight (ToF) endoscope, a standard ToF camera, a stereoscope, and a High Definition Television (HDTV) endoscope. The resulting reconstructed partial organ surfaces were then compared to corresponding ground truth shapes extracted from computed tomography (CT) data using a set of local and global distance metrics. The evaluation suggests that the ToF technique has high potential as means for intraoperative endoscopic surface registration.

  10. The reliability of endoscopic examination in assessment of arytenoid cartilage movement in horses. Part II. Influence of side of examination, reexamination, and sedation.

    PubMed

    Ducharme, N G; Hackett, R P; Fubini, S L; Erb, H N

    1991-01-01

    Twenty Thoroughbred and Standardbred horses underwent endoscopic evaluation of arytenoid cartilage movement twice within 1 week. Each time, a flexible endoscope was passed without sedation through the right nostril and the left nostril, and through the right nostril 5 minutes after administration of xylazine hydrochloride (0.55 mg/kg or 1.1 mg/kg intravenously). Laryngeal cartilage movement was videorecorded. All videotaped images were reviewed by three veterinarians and subjectively placed in one of four grades. The intraobserver agreement rate varied from 52.6% for examination under sedation with 1.1 mg/kg of xylazine to 89.5% for unsedated reexamination through the left nostril. The effect of the various observations on median laryngeal grade was calculated. Examination under xylazine hydrochloride at either dosage yielded a change in median laryngeal grade from the unsedated examination in 45% of the evaluations. Reevaluation through the right or left nostril resulted in a different median laryngeal grade in 21% and 5% of the examinations, respectively. Objective measurements of the rima glottidis obtained by computer-assisted morphometric analysis of the recorded laryngeal images allowed laryngeal images to be dichotomized regardless of the condition of endoscopic examination. Endoscopic evaluation of laryngeal cartilage movement is subjective and is influenced by sedation with xylazine, evaluation through the alternate nostril, and different day of examination. The most consistent evaluation was obtained during repeated examination through the left nostril.

  11. Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule

    PubMed Central

    Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko

    2015-01-01

    Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases. PMID:26600772

  12. Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule.

    PubMed

    Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko

    2015-01-01

    Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases.

  13. Ultrasound-assisted endoscopic partial plantar fascia release.

    PubMed

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.

  14. Ultrasound-Assisted Endoscopic Partial Plantar Fascia Release

    PubMed Central

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure. PMID:24265989

  15. Biplane reconstruction and visualization of virtual endoscopic and fluoroscopic views for interventional device navigation

    NASA Astrophysics Data System (ADS)

    Wagner, Martin G.; Strother, Charles M.; Schafer, Sebastian; Mistretta, Charles A.

    2016-03-01

    Biplane fluoroscopic imaging is an important tool for minimally invasive procedures for the treatment of cerebrovascular diseases. However, finding a good working angle for the C-arms of the angiography system as well as navigating based on the 2D projection images can be a difficult task. The purpose of this work is to propose a novel 4D reconstruction algorithm for interventional devices from biplane fluoroscopy images and to propose new techniques for a better visualization of the results. The proposed reconstruction methods binarizes the fluoroscopic images using a dedicated noise reduction algorithm for curvilinear structures and a global thresholding approach. A topology preserving thinning algorithm is then applied and a path search algorithm minimizing the curvature of the device is used to extract the 2D device centerlines. Finally, the 3D device path is reconstructed using epipolar geometry. The point correspondences are determined by a monotonic mapping function that minimizes the reconstruction error. The three dimensional reconstruction of the device path allows the rendering of virtual fluoroscopy images from arbitrary angles as well as 3D visualizations like virtual endoscopic views or glass pipe renderings, where the vessel wall is rendered with a semi-transparent material. This work also proposes a combination of different visualization techniques in order to increase the usability and spatial orientation for the user. A combination of synchronized endoscopic and glass pipe views is proposed, where the virtual endoscopic camera position is determined based on the device tip location as well as the previous camera position using a Kalman filter in order to create a smooth path. Additionally, vessel centerlines are displayed and the path to the target is highlighted. Finally, the virtual endoscopic camera position is also visualized in the glass pipe view to further improve the spatial orientation. The proposed techniques could considerably improve the workflow of minimally invasive procedures for the treatment of cerebrovascular diseases.

  16. Chronic pancreatitis: diagnosis, classification, and new genetic developments.

    PubMed

    Etemad, B; Whitcomb, D C

    2001-02-01

    The utilization of recent advances in molecular and genomic technologies and progress in pancreatic imaging techniques provided remarkable insight into genetic, environmental, immunologic, and pathobiological factors leading to chronic pancreatitis. Translation of these advances into clinical practice demands a reassessment of current approaches to diagnosis, classification, and staging. We conclude that an adequate pancreatic biopsy must be the gold standard against which all diagnostic approaches are judged. Although computed tomography remains the initial test of choice for the diagnosis of chronic pancreatitis, the roles of endoscopic retrograde pancreatography, endoscopic ultrasonography, and magnetic resonance imaging are considered. Once chronic pancreatitis is diagnosed, proper classification becomes important. Major predisposing risk factors to chronic pancreatitis may be categorized as either (1) toxic-metabolic, (2) idiopathic, (3) genetic, (4) autoimmune, (5) recurrent and severe acute pancreatitis, or (6) obstructive (TIGAR-O system). After classification, staging of pancreatic function, injury, and fibrosis becomes the next major concern. Further research is needed to determine the clinical and natural history of chronic pancreatitis developing in the context of various risk factors. New methods are needed for early diagnosis of chronic pancreatitis, and new therapies are needed to determine whether interventions will delay or prevent the progression of the irreversible damage characterizing end-stage chronic pancreatitis.

  17. High Resolution Sub-MM Fiberoptic Endoscope Final Report CRADA No. TSB-1447-97

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stone, Gary F.; Smith, John

    2018-01-22

    At the time of the CRADA, LLNL needed to develop a sub-mm outer diameter fiberoptic endoscope with 25pm or better resolution at 3-lOmm working distance to support the Enhanced Surveillance Program (ESP) and the Core Surveillance Program for DOE. The commercially available systems did not meet the image resolution requirements and development work was needed to reach three goals. We also needed to perform preliminary investigations into the production of such an endoscope with a steerable-articulated distal end. The goal of such an endoscope was to allow for a 45 degree inspection cone including the lens field of view.

  18. High speed, wide velocity dynamic range Doppler optical coherence tomography (Part III): in vivo endoscopic imaging of blood flow in the rat and human gastrointestinal tracts

    NASA Astrophysics Data System (ADS)

    Yang, Victor X. D.; Gordon, Maggie L.; Tang, Shou-Jiang; Marcon, Norman E.; Gardiner, Geoffrey; Qi, Bing; Bisland, Stuart; Seng-Yue, Emily; Lo, Stewart; Pekar, Julius; Wilson, Brian C.; Vitkin, I. Alex

    2003-09-01

    We previously described a fiber based Doppler optical coherence tomography system [1] capable of imaging embryo cardiac blood flow at 4~16 frames per second with wide velocity dynamic range [2]. Coupling this system to a linear scanning fiber optical catheter design that minimizes friction and vibrations, we report here the initial results of in vivo endoscopic Doppler optical coherence tomography (EDOCT) imaging in normal rat and human esophagus. Microvascular flow in blood vessels less than 100 µm diameter was detected using a combination of color-Doppler and velocity variance imaging modes, during clinical endoscopy using a mobile EDOCT system.

  19. Various Embodiments of the Non-Invasive Endoscopic Feedback for Learning of Voluntary Control of Physiological Functioning

    NASA Technical Reports Server (NTRS)

    Henriksen, Mina D.

    1995-01-01

    The research performed was a small portion of the patent to be submitted by Dr. Alan T. Pope entitled 'A Method of Providing Veridical Non-Invasive Endoscopic Feedback for Learning of Voluntary Control of Physiological Functioning'. The focus of this study is to incorporate the emerging technology of virtual reality with the forms of biofeedback already in existance producing a life-like, real-time model of the body's functioning without using invasive procedures, yet still producing the equivalent of a picture from an invasive endoscopic procedure in the region of interest. The portion of the project designated to me was to research and report as many possible uses for such technology as possible.

  20. Kinect based real-time position calibration for nasal endoscopic surgical navigation system

    NASA Astrophysics Data System (ADS)

    Fan, Jingfan; Yang, Jian; Chu, Yakui; Ma, Shaodong; Wang, Yongtian

    2016-03-01

    Unanticipated, reactive motion of the patient during skull based tumor resective surgery is the source of the consequence that the nasal endoscopic tracking system is compelled to be recalibrated. To accommodate the calibration process with patient's movement, this paper developed a Kinect based Real-time positional calibration method for nasal endoscopic surgical navigation system. In this method, a Kinect scanner was employed as the acquisition part of the point cloud volumetric reconstruction of the patient's head during surgery. Then, a convex hull based registration algorithm aligned the real-time image of the patient head with a model built upon the CT scans performed in the preoperative preparation to dynamically calibrate the tracking system if a movement was detected. Experimental results confirmed the robustness of the proposed method, presenting a total tracking error within 1 mm under the circumstance of relatively violent motions. These results point out the tracking accuracy can be retained stably and the potential to expedite the calibration of the tracking system against strong interfering conditions, demonstrating high suitability for a wide range of surgical applications.

  1. Optical transfection using an endoscope-like system.

    PubMed

    Ma, Nan; Gunn-Moore, Frank; Dholakia, Kishan

    2011-02-01

    Optical transfection is a powerful method for targeted delivery of therapeutic agents to biological cells. A tightly focused pulsed laser beam may transiently change the permeability of a cell membrane to facilitate the delivery of foreign genetic material into cells. We report the first realization of an endoscope-like integrated system for optical transfection. An imaging fiber (coherent optical fiber bundle) with ∼ 6000 cores (pixels) embedded in a fiber cladding of ∼ 300 μm in diameter, produces an image circle (area) of ∼ 270 μm diam. This imaging fiber, with an ordered axicon lens array chemically etched at its exit face, is used for the delivery of a femtosecond laser to the cell membrane for optical transfection along with subcellular resolution imaging. A microcapillary-based microfluidic system for localized drug delivery was also combined in this miniature, flexible system. Using this novel system, a plasmid transfection efficiency up to ∼ 72% was obtained for CHO-K1 cells. This endoscope-like system opens a range of exciting applications, in particular, in the targeted in vivo optical microsurgery area.

  2. Latest generation, wide-angle, high-definition colonoscopes increase adenoma detection rate.

    PubMed

    Adler, Andreas; Aminalai, Alireza; Aschenbeck, Jens; Drossel, Rolf; Mayr, Michael; Scheel, Mathias; Schröder, Andreas; Yenerim, Timur; Wiedenmann, Bertram; Gauger, Ulrich; Roll, Stephanie; Rösch, Thomas

    2012-02-01

    Improvements to endoscopy imaging technologies might improve detection rates of colorectal cancer and patient outcomes. We compared the accuracy of the latest generation of endoscopes with older generation models in detection of colorectal adenomas. We compared data from 2 prospective screening colonoscopy studies (the Berlin Colonoscopy Project 6); each study lasted approximately 6 months and included the same 6 colonoscopists, who worked in private practice. Participants in group 1 (n = 1256) were all examined by using the latest generation of wide-angle, high-definition colonoscopes that were manufactured by the same company. Individuals in group 2 (n = 1400) were examined by endoscopists who used routine equipment (a mixture of endoscopes from different companies; none of those used to examine group 1). The adenoma detection rate was calculated on the basis of the number of all adenomas/number of all patients. There were no differences in patient parameters or withdrawal time between groups (8.0 vs 8.2 minutes). The adenoma detection rate was significantly higher in group 1 (0.33) than in group 2 (0.27; P = .01); a greater number of patients with least 1 adenoma were identified in group 1 (22.1%) than in group 2 (18.2%; P = .01). A higher percentage of high-grade dysplastic adenomas were detected in group 1 (1.19%) than in group 2 (0.57%), but this difference was not statistically significant (P = .06). The latest generation of wide-angle, high-definition colonoscopes improves rates of adenoma detection by 22%, compared with mixed, older technology endoscopes used in routine private practice. These findings might affect definitions of quality control parameters for colonoscopy screening for colorectal cancer. Copyright © 2012 AGA Institute. Published by Elsevier Inc. All rights reserved.

  3. Endoscopy in neuro-otologic surgery.

    PubMed

    Wackym, Phillip A; King, Wesley A; Meyer, Glenn A; Poe, Dennis S

    2002-04-01

    Endoscopy offers several distinct advantages over the operating microscope during neuro-otologic surgery that make it an excellent adjunctive tool to the microscope or independent modality during cranial base surgery. The high magnification gives excellent definition of perforating blood vessels, cranial nerves, and neural structures, which in many cases is superior to that achieved with the microscope. Furthermore, the use of angled or flexible endoscopes allows one to look around corners and behind anatomic structures blocking the view seen via a 0 degree microscope. Endoscopy also has the theoretical advantage that a less invasive operative procedure is required, which should reduce the operative morbidity. Several notable disadvantages of endoscopy include the problems associated with blood soiling the endoscope, making visualization difficult or impossible, the lack of readily available instrumentation designed specifically for endoscopic neuro-otology, and the poor overview of the operative field. This last point is an important one because the endoscope is placed adjacent to the lesion and does not allow one to look backward to prevent [figure: see text] injury to structures next to the shaft of the telescope. Furthermore, the surgeon must be cognizant of potential thermal injury to structures caused by the heat generated by the light source. The present endoscopic technology limits the image that the surgeon sees to two dimensions, which results in certain unique problems when operating in a three-dimensional milieu. Because of this, there is a steep learning curve to acquire endoscopic dexterity and three-dimensional orientation. Finally, bimanual operation requires the use of an articulated endoscope holder or the commitment of the co-surgeon to hold the endoscope. One of the limitations of the operative microscope is that the angle of view is determined by the distance of the lens to the skull, retractor, or obstructing tissue, which is a function of the lens focal length; the longer the focal length, the narrower the viewing angle. During most microsurgical procedures, the focal distance varies between 200 and 400 mm. Using a previous analogy, if one looks through a door's keyhole at close range, nearly the entire room on the opposite side of the door can be seen, although nothing can be seen when the hole is viewed from a long distance. This is similar to what happens when using the endoscope with focal lengths ranging from 5 to 20 mm: a wider angle of view can be achieved. Based on their, experience the authors believe that endoscopes can be used safely during neuro-otologic surgery. As an adjunct to or substitution for the operative microscope, this modality does improve visualization of bony, neural, and vascular structures while minimizing cerebellar retraction.

  4. Endoscopic OCT for imaging of uterine body and cervix pathologies

    NASA Astrophysics Data System (ADS)

    Shakhova, Natalia M.; Kuznetzova, Irina N.; Gladkova, Natalia D.; Snopova, Ludmila; Gelikonov, Valentin M.; Gelikonov, Grigory V.; Feldchtein, Felix I.; Kuranov, Roman V.; Sergeev, Alexander M.

    1998-04-01

    First results of endoscopic applications of optical coherence tomography (OCT) in gynecology are presented. We have studied mucosa of uterus, uterine cervix and vagina in vivo. Images of healthy endometrium in different stages of menstrual cycle have been recorded. For uterine cervix not only OCT data of normal state but some kids of pathology have been analyzed. Capability of OCT to identify alterations of mucosa makes this method promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  5. Fiber-optic-bundle-based optical coherence tomography.

    PubMed

    Xie, Tuqiang; Mukai, David; Guo, Shuguang; Brenner, Matthew; Chen, Zhongping

    2005-07-15

    A fiber-optic-bundle-based optical coherence tomography (OCT) probe method is presented. The experimental results demonstrate this multimode optical fiber-bundle-based OCT system can achieve a lateral resolution of 12 microm and an axial resolution of 10 microm with a superluminescent diode source. This novel OCT imaging approach eliminates any moving parts in the probe and has a primary advantage for use in extremely compact and safe OCT endoscopes for imaging internal organs and great potential to be combined with confocal endoscopic microscopy.

  6. Confocal Endomicroscopy: Instrumentation and Medical Applications

    PubMed Central

    Jabbour, Joey M.; Saldua, Meagan A.; Bixler, Joel N.; Maitland, Kristen C.

    2013-01-01

    Advances in fiber optic technology and miniaturized optics and mechanics have propelled confocal endomicroscopy into the clinical realm. This high resolution, non-invasive imaging technology provides the ability to microscopically evaluate cellular and sub-cellular features in tissue in vivo by optical sectioning. Because many cancers originate in epithelial tissues accessible by endoscopes, confocal endomicroscopy has been explored to detect regions of possible neoplasia at an earlier stage by imaging morphological features in vivo that are significant in histopathologic evaluation. This technique allows real-time assessment of tissue which may improve diagnostic yield by guiding biopsy. Research and development continues to reduce the overall size of the imaging probe, increase the image acquisition speed, and improve resolution and field of view of confocal endomicroscopes. Technical advances will continue to enable application to less accessible organs and more complex systems in the body. Lateral and axial resolutions down to 0.5 μm and 3 μm, respectively, field of view as large as 800×450 μm, and objective lens and total probe outer diameters down to 350 μm and 1.25 mm, respectively, have been achieved. We provide a review of the historical developments of confocal imaging in vivo, the evolution of endomicroscope instrumentation, and the medical applications of confocal endomicroscopy. PMID:21994069

  7. "Leopard skin sign": the use of narrow-band imaging with magnification endoscopy in celiac disease.

    PubMed

    Tchekmedyian, Asadur J; Coronel, Emmanuel; Czul, Frank

    2014-01-01

    Celiac Disease (CD) is an immune reaction to gluten containing foods such as rye, wheat and barley. This condition affects individuals with a genetic predisposition; it targets the small bowel and may cause symptoms including diarrhea, malabsorption, weight loss, abdominal pain and bloating. The diagnosis is made by serologic testing of celiac-specific antibodies and confirmed by histology. Certain endoscopic characteristics, such as scalloping, reduction in the number of folds, mosaic-pattern mucosa or nodular mucosa, are suggestive of CD and can be visualized under white light endoscopy. Due to its low sensitivity, endoscopy alone is not recommended to diagnose CD; however, enhanced visual identification of suspected mucosal abnormalities through the use of new technologies, such as narrow band imaging with magnification (NBI-ME), could assist in targeting biopsies and thereby increasing the sensitivity of endoscopy. This is a case series of seven patients with serologic and histologic diagnoses of CD who underwent upper endoscopies with NBI-ME imaging technology as part of their CD evaluation. By employing this imaging technology, we could identify patchy atrophy sites in a mosaic pattern, with flattened villi and alteration of the central capillaries of the duodenal mucosa. We refer to this epithelial pattern as "Leopard Skin Sign". Since epithelial lesions are easily seen using NBI-ME, we found it beneficial for identifying and targeting biopsy sites. Larger prospective studies are warranted to confirm our findings.

  8. Depth-resolved imaging of colon tumor using optical coherence tomography and fluorescence laminar optical tomography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Tang, Qinggong; Frank, Aaron; Wang, Jianting; Chen, Chao-wei; Jin, Lily; Lin, Jon; Chan, Joanne M.; Chen, Yu

    2016-03-01

    Early detection of neoplastic changes remains a critical challenge in clinical cancer diagnosis and treatment. Many cancers arise from epithelial layers such as those of the gastrointestinal (GI) tract. Current standard endoscopic technology is unable to detect those subsurface lesions. Since cancer development is associated with both morphological and molecular alterations, imaging technologies that can quantitative image tissue's morphological and molecular biomarkers and assess the depth extent of a lesion in real time, without the need for tissue excision, would be a major advance in GI cancer diagnostics and therapy. In this research, we investigated the feasibility of multi-modal optical imaging including high-resolution optical coherence tomography (OCT) and depth-resolved high-sensitivity fluorescence laminar optical tomography (FLOT) for structural and molecular imaging. APC (adenomatous polyposis coli) mice model were imaged using OCT and FLOT and the correlated histopathological diagnosis was obtained. Quantitative structural (the scattering coefficient) and molecular imaging parameters (fluorescence intensity) from OCT and FLOT images were developed for multi-parametric analysis. This multi-modal imaging method has demonstrated the feasibility for more accurate diagnosis with 87.4% (87.3%) for sensitivity (specificity) which gives the most optimal diagnosis (the largest area under receiver operating characteristic (ROC) curve). This project results in a new non-invasive multi-modal imaging platform for improved GI cancer detection, which is expected to have a major impact on detection, diagnosis, and characterization of GI cancers, as well as a wide range of epithelial cancers.

  9. Endoscopic foraminal decompression for failed back surgery syndrome under local anesthesia.

    PubMed

    Yeung, Anthony; Gore, Satishchandra

    2014-01-01

    The most common causes of failed back surgery are residual or recurrent herniation, foraminal fibrosis and foraminal stenosis that is ignored, untreated, or undertreated. Residual back ache may also be from facetal causes or denervation and scarring of the paraspinal muscles.(1-6) The original surgeon may advise his patient that nothing more can be done on the basis of his opinion that the nerve was visually decompressed by the original surgery, supported by improved post-op imaging and follow-up studies such as EMG and conduction velocity studies. Post-op imaging or electrophysiological assessment may be inadequate to explain all the reasons for residual or recurrent symptoms. Treatment of Failed back surgery by repeat traditional open revision surgery usually incorporates more extensive decompression causing increased instability and back pain, therefore necessitating fusion. The authors, having limited their practice to endoscopic MIS surgery over the last 15-20 years, report on their experience gained during that period to relieve pain by endoscopically visualizing and treating unrecognized causative patho-anatomy in FBSS.(7.) Thirty consecutive patients with FBSS presenting with back and leg pain that had supporting imaging diagnosis of lateral stenosis and /or residual / recurrent disc herniation, or whose pain complaint was supported by relief from diagnostic and therapeutic injections (Figure 1), were offered percutaneous transforaminal endoscopic discectomy and foraminoplasty over a repeat open procedure. Each patient sought consultation following a transient successful, partially successful or unsuccessful open translaminar surgical treatment for disc herniation or spinal stenosis. Endoscopic foraminoplasty was also performed to either decompress the bony foramen for foraminal stenosis, or foraminoplasty to allow for endoscopic visual examination of the affected traversing and exiting nerve roots in the axilla, also known as the "hidden zone" of Macnab (Figure 2).(8, 9) The average follow up time was, average 40 months, minimum 12 months. Outcome data at each visit included Macnab, VAS and ODI. Fig. 1A diagnostic and therapeutic epidural gram may help identify unrecognized lateral recess stenosis underestimated by MRI. An excellent result from a therapeutic block lends excellent prognosis for a more lasting and "permanent" result from transforaminal endoscopic lateral recess decompression.Fig. 2Kambin's Triangle provides access to the "hidden zone" of Macnab by foraminoplasty. The foramen and lateral recess is decompressed by removing the ventral aspect and tip of the superior articular process to gain access to the axilla between the traversing and exiting nerve. FBSS contains patho-anatomy in the axilla between the traversing and exiting nerve that hides the pain generators of FBSS. The average pre-operative VAS improved from 7.2 to 4.0, and ODI 48% to 31%. While temporary dysesthesia occurred in 4 patients in the early post-operative period, all were happy, as all received additional relief of their pre-op symptoms. They were also relieved to be able to avoid "open" decompression or fusion surgery. The transforaminal endoscopic approach is effective for FBSS due to residual/recurrent HNP and lateral stenosis. Failed initial index surgery may involve failure to recognize patho-anatomy in the axilla of the foramen housing the traversing and the exiting nerve, including the DRG, which is located cephalad and near the tip of SAP.(10) The transforaminal endoscopic approach effectively decompresses the foramen and does not further destabilize the spine needing stabilization.(11) It also avoids going through the previous surgical site. Disc narrowing as a consequence of translaminar discectomy and progressive degenerative narrowing and spondylolisthesis (Figure 3) as a natural history of degenerative disc disease can lead to central and lateral stenosis. The MRI may underestimate the degree of stenosis from a bulging or a foraminal disc protrusion and residual lateral recess stenosis. Pain can be diagnosed and confirmed by evocative discography and by clinical response to transforaminal diagnostic and therapeutic steroid injections.(12) Foraminal endoscopic decompression of the lateral recess is a MIS technique that does not "burn bridges" for a more conventional approach and it adds to the surgical armamentarium of FBSS. Fig. 3Cadaver Illustration of Foraminal Stenosis (courtesy of Wolfgang Rauschning). As the disc narrows, the superior articular process impinges on the exiting nerve and DRG, creating lateral recess stenosis, lumbar spondylosis, and facet arthrosis.

  10. Endoscopic Foraminal Decompression for Failed Back Surgery Syndrome under local Anesthesia

    PubMed Central

    Gore, Satishchandra

    2014-01-01

    Background The most common causes of failed back surgery are residual or recurrent herniation, foraminal fibrosis and foraminal stenosis that is ignored, untreated, or undertreated. Residual back ache may also be from facetal causes or denervation and scarring of the paraspinal muscles.1–6 The original surgeon may advise his patient that nothing more can be done on the basis of his opinion that the nerve was visually decompressed by the original surgery, supported by improved post-op imaging and follow-up studies such as EMG and conduction velocity studies. Post-op imaging or electrophysiological assessment may be inadequate to explain all the reasons for residual or recurrent symptoms. Treatment of Failed back surgery by repeat traditional open revision surgery usually incorporates more extensive decompression causing increased instability and back pain, therefore necessitating fusion. The authors, having limited their practice to endoscopic MIS surgery over the last 15-20 years, report on their experience gained during that period to relieve pain by endoscopically visualizing and treating unrecognized causative patho-anatomy in FBSS.7 Methods Thirty consecutive patients with FBSS presenting with back and leg pain that had supporting imaging diagnosis of lateral stenosis and /or residual / recurrent disc herniation, or whose pain complaint was supported by relief from diagnostic and therapeutic injections (Figure 1), were offered percutaneous transforaminal endoscopic discectomy and foraminoplasty over a repeat open procedure. Each patient sought consultation following a transient successful, partially successful or unsuccessful open translaminar surgical treatment for disc herniation or spinal stenosis. Endoscopic foraminoplasty was also performed to either decompress the bony foramen for foraminal stenosis, or foraminoplasty to allow for endoscopic visual examination of the affected traversing and exiting nerve roots in the axilla, also known as the “hidden zone” of Macnab (Figure 2).8, 9 The average follow up time was, average 40 months, minimum 12 months. Outcome data at each visit included Macnab, VAS and ODI. Fig. 1 A diagnostic and therapeutic epidural gram may help identify unrecognized lateral recess stenosis underestimated by MRI. An excellent result from a therapeutic block lends excellent prognosis for a more lasting and “permanent” result from transforaminal endoscopic lateral recess decompression. Fig. 2 Kambin's Triangle provides access to the “hidden zone” of Macnab by foraminoplasty. The foramen and lateral recess is decompressed by removing the ventral aspect and tip of the superior articular process to gain access to the axilla between the traversing and exiting nerve. FBSS contains patho-anatomy in the axilla between the traversing and exiting nerve that hides the pain generators of FBSS. Results The average pre-operative VAS improved from 7.2 to 4.0, and ODI 48% to 31%. While temporary dysesthesia occurred in 4 patients in the early post-operative period, all were happy, as all received additional relief of their pre-op symptoms. They were also relieved to be able to avoid “open” decompression or fusion surgery. Conclusions / Level of Evidence 3 The transforaminal endoscopic approach is effective for FBSS due to residual/recurrent HNP and lateral stenosis. Failed initial index surgery may involve failure to recognize patho-anatomy in the axilla of the foramen housing the traversing and the exiting nerve, including the DRG, which is located cephalad and near the tip of SAP.10 The transforaminal endoscopic approach effectively decompresses the foramen and does not further destabilize the spine needing stabilization.11 It also avoids going through the previous surgical site. Clinical Relevance Disc narrowing as a consequence of translaminar discectomy and progressive degenerative narrowing and spondylolisthesis (Figure 3) as a natural history of degenerative disc disease can lead to central and lateral stenosis. The MRI may underestimate the degree of stenosis from a bulging or a foraminal disc protrusion and residual lateral recess stenosis. Pain can be diagnosed and confirmed by evocative discography and by clinical response to transforaminal diagnostic and therapeutic steroid injections.12 Foraminal endoscopic decompression of the lateral recess is a MIS technique that does not “burn bridges” for a more conventional approach and it adds to the surgical armamentarium of FBSS. Fig. 3 Cadaver Illustration of Foraminal Stenosis (courtesy of Wolfgang Rauschning). As the disc narrows, the superior articular process impinges on the exiting nerve and DRG, creating lateral recess stenosis, lumbar spondylosis, and facet arthrosis. PMID:25694939

  11. Endoscopic optical coherence tomography for imaging the tympanic membrane

    NASA Astrophysics Data System (ADS)

    Burkhardt, Anke; Walther, Julia; Cimalla, Peter; Bornitz, Matthias; Koch, Edmund

    2011-06-01

    Optical coherence tomography (OCT) is an imaging modality that enables micrometer-scale contactless subsurface imaging of biological tissue. Endoscopy, as another imaging method, has the potential of imaging tubular organs and cavities and therefore has opened up several application areas not accessible before. The combination of OCT and endoscopy uses the advantages of both methods and consequently allows additional imaging of structures beneath surfaces inside cavities. Currently, visual investigations on the surface of the human tympanic membrane are possible but only with expert eyes. up to now, visual imaging of the outer ear up to the tympanic membrane can be carried out by an otoscope, an operating microscope or an endoscope. In contrast to these devices, endoscopy has the advantage of imaging the whole tympanic membrane with one view. The intention of this research is the development of an endoscopic optical coherence tomography (EOCT) device for imaging the tympanic membrane depth-resolved and structures behind it. Detection of fluids in the middle ear, which function as an indicator for otitis media, could help to avoid the application of antibiotics. It is possible to detect a congeries of fluids with the otoscope but the ambition is to the early detection by OCT. The developed scanner head allows imaging in working distances in the range from zero up to 5 mm with a field of view of 2 mm. In the next step, the scanner head should be improved to increase the working distance and the field of view.

  12. 2D-3D registration using gradient-based MI for image guided surgery systems

    NASA Astrophysics Data System (ADS)

    Yim, Yeny; Chen, Xuanyi; Wakid, Mike; Bielamowicz, Steve; Hahn, James

    2011-03-01

    Registration of preoperative CT data to intra-operative video images is necessary not only to compare the outcome of the vocal fold after surgery with the preplanned shape but also to provide the image guidance for fusion of all imaging modalities. We propose a 2D-3D registration method using gradient-based mutual information. The 3D CT scan is aligned to 2D endoscopic images by finding the corresponding viewpoint between the real camera for endoscopic images and the virtual camera for CT scans. Even though mutual information has been successfully used to register different imaging modalities, it is difficult to robustly register the CT rendered image to the endoscopic image due to varying light patterns and shape of the vocal fold. The proposed method calculates the mutual information in the gradient images as well as original images, assigning more weight to the high gradient regions. The proposed method can emphasize the effect of vocal fold and allow a robust matching regardless of the surface illumination. To find the viewpoint with maximum mutual information, a downhill simplex method is applied in a conditional multi-resolution scheme which leads to a less-sensitive result to local maxima. To validate the registration accuracy, we evaluated the sensitivity to initial viewpoint of preoperative CT. Experimental results showed that gradient-based mutual information provided robust matching not only for two identical images with different viewpoints but also for different images acquired before and after surgery. The results also showed that conditional multi-resolution scheme led to a more accurate registration than single-resolution.

  13. A Clinical Wide-Field Fluorescence Endoscopic Device for Molecular Imaging Demonstrating Cathepsin Protease Activity in Colon Cancer

    PubMed Central

    Sensarn, Steven; Zavaleta, Cristina L.; Segal, Ehud; Rogalla, Stephan; Lee, Wansik; Gambhir, Sanjiv S.; Bogyo, Matthew; Contag, Christopher H.

    2017-01-01

    Purpose Early and effective detection of cancers of the gastrointestinal tract will require novel molecular probes and advances in instrumentation that can reveal functional changes in dysplastic and malignant tissues. Here, we describe adaptation of a wide-field clinical fiberscope to perform wide-field fluorescence imaging while preserving its white-light capability for the purpose of providing wide-field fluorescence imaging capability to point-of-care microscopes. Procedures We developed and used a fluorescent fiberscope to detect signals from a quenched probe, BMV109, that becomes fluorescent when cleaved by, and covalently bound to, active cathepsin proteases. Cathepsins are expressed in inflammation- and tumor-associated macrophages as well as directly from tumor cells and are a promising target for cancer imaging. The fiberscope has a 1-mm outer diameter enabling validation via endoscopic exams in mice, and therefore we evaluated topically applied BMV109 for the ability to detect colon polyps in an azoxymethane-induced colon tumor model in mice. Results This wide-field endoscopic imaging device revealed consistent and clear fluorescence signals from BMV109 that specifically localized to the polypoid regions as opposed to the normal adjacent colon tissue (p < 0.004) in the murine colon carcinoma model. Conclusions The sensitivity of detection of BMV109 with the fluorescence fiberscope suggested utility of these tools for early detection at hard-to-reach sites. The fiberscope was designed to be used in conjunction with miniature, endoscope-compatible fluorescence microscopes for dual wide-field and microscopic cancer detection. PMID:27154508

  14. Automatic classification of minimally invasive instruments based on endoscopic image sequences

    NASA Astrophysics Data System (ADS)

    Speidel, Stefanie; Benzko, Julia; Krappe, Sebastian; Sudra, Gunther; Azad, Pedram; Müller-Stich, Beat Peter; Gutt, Carsten; Dillmann, Rüdiger

    2009-02-01

    Minimally invasive surgery is nowadays a frequently applied technique and can be regarded as a major breakthrough in surgery. The surgeon has to adopt special operation-techniques and deal with difficulties like the complex hand-eye coordination and restricted mobility. To alleviate these constraints we propose to enhance the surgeon's capabilities by providing a context-aware assistance using augmented reality techniques. To analyze the current situation for context-aware assistance, we need intraoperatively gained sensor data and a model of the intervention. A situation consists of information about the performed activity, the used instruments, the surgical objects, the anatomical structures and defines the state of an intervention for a given moment in time. The endoscopic images provide a rich source of information which can be used for an image-based analysis. Different visual cues are observed in order to perform an image-based analysis with the objective to gain as much information as possible about the current situation. An important visual cue is the automatic recognition of the instruments which appear in the scene. In this paper we present the classification of minimally invasive instruments using the endoscopic images. The instruments are not modified by markers. The system segments the instruments in the current image and recognizes the instrument type based on three-dimensional instrument models.

  15. An Update to Hepatobiliary Stents

    PubMed Central

    Moy, Brian T.; Birk, John W.

    2015-01-01

    Endoscopic stent placement is a common primary management therapy for benign and malignant biliary strictures. However, continuous use of stents is limited by occlusion and migration. Stent technology has evolved significantly over the past two decades to reduce these problems. The purpose of this article is to review current guidelines in managing malignant and benign biliary obstructions, current endoscopic techniques for stent placement, and emerging stent technology. What began as a simple plastic stent technology has evolved significantly to include uncovered, partially covered, and fully covered self-expanding metal stents (SEMS) as well as magnetic, bioabsorbable, drug-eluting, and antireflux stents.1 PMID:26357636

  16. Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy

    NASA Astrophysics Data System (ADS)

    Rata, Mihaela; Salomir, Rares; Umathum, Reiner; Jenne, Jürgen; Lafon, Cyril; Cotton, François; Bock, Michael

    2008-11-01

    High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 × 0.25 × 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 × 0.5 × 5 mm3, 2.2 s/image, 0.3 °C voxel-wise SDT) were acquired in an ex vivo esophagus sample, on a clinical 1.5T scanner. The endoscopic device was actively operated under automatic temperature control, demonstrating a high level of accuracy (1.7% standard deviation, 1.1% error of mean value), which indicates that this technology may be suitable for HICU therapy of endoluminal cancer.

  17. Exploration of assistive technology for uniform laparoscopic surgery.

    PubMed

    Sato, Masakazu; Koizumi, Minako; Hino, Takahiro; Takahashi, Yu; Nagashima, Natsuki; Itaoka, Nao; Ueshima, Chiharu; Nakata, Maki; Hasumi, Yoko

    2018-02-19

    Laparoscopic surgery is less invasive than open surgery and is now common in various medical fields. However, laparoscopic surgery is more difficult than open surgery and often requires additional time for the operator to achieve mastery. Therefore, we investigated the use of assistive technology for uniform laparoscopic surgery. We used the OpenCV2 library for augmented reality with an ArUco marker to detect and estimate forceps positioning. We used Sense HAT as the gyro sensor. The development platforms used were Mac OS X 10.11.3 and Raspberry Pi 3, model B. By attaching the ArUco marker to the needle holder, we could draw a line vertically to the marker. When the needle was held, a cube could be imagined, and both the needle and lines could be used to determine the appropriate position. By attaching the gyro sensor to the camera, we could detect its angle of rotation. We obtained stabilized images by rotating the image by the detected degrees; this was possible for any camera position. Assistive technology allowed us to obtain consecutive converted images in real time and may be readily applicable to clinical practice. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  18. Miniature in vivo robotics and novel robotic surgical platforms.

    PubMed

    Shah, Bhavin C; Buettner, Shelby L; Lehman, Amy C; Farritor, Shane M; Oleynikov, Dmitry

    2009-05-01

    Robotic surgical systems, such as the da Vinci Surgical System (Intuitive Surgical, Inc., Sunnyvale, California), have revolutionized laparoscopic surgery but are limited by large size, increased costs, and limitations in imaging. Miniature in vivo robots are being developed that are inserted entirely into the peritoneal cavity for laparoscopic and natural orifice transluminal endoscopic surgical (NOTES) procedures. In the future, miniature camera robots and microrobots should be able to provide a mobile viewing platform. This article discusses the current state of miniature robotics and novel robotic surgical platforms and the development of future robotic technology for general surgery and urology.

  19. Fluorescence endoscopic imaging study of anastomotic recurrence of Crohn's disease after right ileocolonic resection

    NASA Astrophysics Data System (ADS)

    Mordon, Serge R.; Maunoury, Vincent; Klein, Olivier; Colombel, Jean-Frederic

    1995-12-01

    Crohn's disease is an inflammatory bowel disease of unknown etiology. Vasculitis is hypothesized but it was never demonstrated in vivo. This study aimed to evaluate the vascular mucosa perfusion using fluorescence imaging in 13 patients who had previously undergone eileocolonic resection and who agreed to participate in a prospective endoscopic study of anastomotic recurrence. This anastomotic recurrence rate is known to be high (73% after 1 year follow-up) and is characterized by ulcerations. The fluorescence study was started with an I.V. bolus injection of sodium fluorescein. The pre-anastomotic mucosa was endoscopically examined with blue light that stimulates fluorescein fluorescence. Fluorescence emission was recorded with an ultra-high-sensitivity camera connected to the endoscope via an interference filter (520 - 560 nm). A uniform fluorescence was observed a few seconds after the injection and lasted for 15 min in healthy subjects. In case of recurrence, the centers of the ulcerations displayed a very low fluorescence indicating localized ischemia. In contrast, the rims of the ulcers revealed brighter fluorescent images than those of normal mucosa. The anastomotic ulcerations of Crohn's disease recurrence exhibit a high fluorescence intensity at their margins indicating an increased mucosal blood flow and/or enhanced transcapillary diffusion. These findings support the hypothesis of a primary vasculitis in Crohn's disease.

  20. Smart imaging of acute lung injury: exploration of myeloperoxidase activity using in vivo endoscopic confocal fluorescence microscopy.

    PubMed

    Chagnon, Frédéric; Bourgouin, Alexandra; Lebel, Réjean; Bonin, Marc-André; Marsault, Eric; Lepage, Martin; Lesur, Olivier

    2015-09-15

    The pathophysiology of acute lung injury (ALI) is well characterized, but its real-time assessment at bedside remains a challenge. When patients do not improve after 1 wk despite supportive therapies, physicians have to consider open lung biopsy (OLB) to identify the process(es) at play. Sustained inflammation and inadequate repair are often observed in this context. OLB is neither easy to perform in a critical setting nor exempt from complications. Herein, we explore intravital endoscopic confocal fluorescence microscopy (ECFM) of the lung in vivo combined with the use of fluorescent smart probe(s) activated by myeloperoxidase (MPO). MPO is a granular enzyme expressed by polymorphonuclear neutrophils (PMNs) and alveolar macrophages (AMs), catalyzing the synthesis of hypoclorous acid, a by-product of hydrogen peroxide. Activation of these probes was first validated in vitro in relevant cells (i.e., AMs and PMNs) and on MPO-non-expressing cells (as negative controls) and then tested in vivo using three rat models of ALI and real-time intravital imaging with ECFM. Semiquantitative image analyses revealed that in vivo probe-related cellular/background fluorescence was associated with corresponding enhanced lung enzymatic activity and was partly prevented by specific MPO inhibition. Additional ex vivo phenotyping was performed, confirming that fluorescent cells were neutrophil elastase(+) (PMNs) or CD68(+) (AMs). This work is a first step toward "virtual biopsy" of ALI without OLB. Copyright © 2015 the American Physiological Society.

  1. Detecting fluorescence hot-spots using mosaic maps generated from multimodal endoscope imaging

    NASA Astrophysics Data System (ADS)

    Yang, Chenying; Soper, Timothy D.; Seibel, Eric J.

    2013-03-01

    Fluorescence labeled biomarkers can be detected during endoscopy to guide early cancer biopsies, such as high-grade dysplasia in Barrett's Esophagus. To enhance intraoperative visualization of the fluorescence hot-spots, a mosaicking technique was developed to create full anatomical maps of the lower esophagus and associated fluorescent hot-spots. The resultant mosaic map contains overlaid reflectance and fluorescence images. It can be used to assist biopsy and document findings. The mosaicking algorithm uses reflectance images to calculate image registration between successive frames, and apply this registration to simultaneously acquired fluorescence images. During this mosaicking process, the fluorescence signal is enhanced through multi-frame averaging. Preliminary results showed that the technique promises to enhance the detectability of the hot-spots due to enhanced fluorescence signal.

  2. Inflammatory bowel disease imaging: Current practice and future directions.

    PubMed

    Kilcoyne, Aoife; Kaplan, Jess L; Gee, Michael S

    2016-01-21

    The purpose of this paper is to evaluate the role of imaging in inflammatory bowel disease (IBD), including detection of extraluminal complications and extraintestinal manifestations of IBD, assessment of disease activity and treatment response, and discrimination of inflammatory from fibrotic strictures. IBD is a chronic idiopathic disease affecting the gastrointestinal tract that is comprised of two separate, but related intestinal disorders; Crohn's disease and ulcerative colitis. The paper discusses, in detail the pros and cons of the different IBD imaging modalities that need to be considered in order to optimize the imaging and clinical evaluation of patients with IBD. Historically, IBD evaluation of the bowel has included imaging to assess the portions of the small bowel that are inaccessible to optical endoscopic visualization. This traditionally was performed using barium fluoroscopic techniques; however, cross-sectional imaging techniques (computed tomography and magnetic resonance imaging) are being increasingly utilized for IBD evaluation because they can simultaneously assess mural and extramural IBD manifestations. Recent advances in imaging technology, that continue to improve the ability of imaging to noninvasively follow disease activity and treatment response, are also discussed. This review article summarizes the current imaging approach in inflammatory bowel disease as well as the role of emerging imaging modalities.

  3. A wideband spiral antenna for ingestible capsule endoscope systems: experimental results in a human phantom and a pig.

    PubMed

    Lee, Sang Heun; Lee, Jaebok; Yoon, Young Joong; Park, Sangbok; Cheon, Changyul; Kim, Kihyun; Nam, Sangwook

    2011-06-01

    This paper presents the design of a wideband spiral antenna for ingestible capsule endoscope systems and a comparison between the experimental results in a human phantom and a pig under general anesthesia. As wireless capsule endoscope systems transmit real-time internal biological image data at a high resolution to external receivers and because they operate in the human body, a small wideband antenna is required. To incorporate these properties, a thick-arm spiral structure is applied to the designed antenna. To make practical and efficient use of antennas inside the human body, which is composed of a high dielectric and lossy material, the resonance characteristics and radiation patterns were evaluated through a measurement setup using a liquid human phantom. The total height of the designed antenna is 5 mm and the diameter is 10 mm. The fractional bandwidth of the fabricated antenna is about 21% with a voltage standing-wave ratio of less than 2, and it has an isotropic radiation pattern. These characteristics are suitable for wideband capsule endoscope systems. Moreover, the received power level was measured using the proposed antenna, a circular polarized receiver antenna, and a pig under general anesthesia. Finally, endoscopic capsule images in the stomach and large intestine were captured using an on-off keying transceiver system.

  4. An integrated approach to endoscopic instrument tracking for augmented reality applications in surgical simulation training.

    PubMed

    Loukas, Constantinos; Lahanas, Vasileios; Georgiou, Evangelos

    2013-12-01

    Despite the popular use of virtual and physical reality simulators in laparoscopic training, the educational potential of augmented reality (AR) has not received much attention. A major challenge is the robust tracking and three-dimensional (3D) pose estimation of the endoscopic instrument, which are essential for achieving interaction with the virtual world and for realistic rendering when the virtual scene is occluded by the instrument. In this paper we propose a method that addresses these issues, based solely on visual information obtained from the endoscopic camera. Two different tracking algorithms are combined for estimating the 3D pose of the surgical instrument with respect to the camera. The first tracker creates an adaptive model of a colour strip attached to the distal part of the tool (close to the tip). The second algorithm tracks the endoscopic shaft, using a combined Hough-Kalman approach. The 3D pose is estimated with perspective geometry, using appropriate measurements extracted by the two trackers. The method has been validated on several complex image sequences for its tracking efficiency, pose estimation accuracy and applicability in AR-based training. Using a standard endoscopic camera, the absolute average error of the tip position was 2.5 mm for working distances commonly found in laparoscopic training. The average error of the instrument's angle with respect to the camera plane was approximately 2°. The results are also supplemented by video segments of laparoscopic training tasks performed in a physical and an AR environment. The experiments yielded promising results regarding the potential of applying AR technologies for laparoscopic skills training, based on a computer vision framework. The issue of occlusion handling was adequately addressed. The estimated trajectory of the instruments may also be used for surgical gesture interpretation and assessment. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Neurosurgical endoscopic training via a realistic 3-dimensional model with pathology.

    PubMed

    Waran, Vicknes; Narayanan, Vairavan; Karuppiah, Ravindran; Thambynayagam, Hari Chandran; Muthusamy, Kalai Arasu; Rahman, Zainal Ariff Abdul; Kirollos, Ramez Wadie

    2015-02-01

    Training in intraventricular endoscopy is particularly challenging because the volume of cases is relatively small and the techniques involved are unlike those usually used in conventional neurosurgery. Present training models are inadequate for various reasons. Using 3-dimensional (3D) printing techniques, models with pathology can be created using actual patient's imaging data. This technical article introduces a new training model based on a patient with hydrocephalus secondary to a pineal tumour, enabling the models to be used to simulate third ventriculostomies and pineal biopsies. Multiple models of the head of a patient with hydrocephalus were created using 3D rapid prototyping technique. These models were modified to allow for a fluid-filled ventricular system under appropriate tension. The models were qualitatively assessed in the various steps involved in an endoscopic third ventriculostomy and intraventricular biopsy procedure, initially by 3 independent neurosurgeons and subsequently by 12 participants of an intraventricular endoscopy workshop. All 3 surgeons agreed on the ease and usefulness of these models in the teaching of endoscopic third ventriculostomy, performing endoscopic biopsies, and the integration of navigation to ventriculoscopy. Their overall score for the ventricular model realism was above average. The 12 participants of the intraventricular endoscopy workshop averaged between a score of 4.0 to 4.6 of 5 for every individual step of the procedure. Neurosurgical endoscopic training currently is a long process of stepwise training. These 3D printed models provide a realistic simulation environment for a neuroendoscopy procedure that allows safe and effective teaching of navigation and endoscopy in a standardized and repetitive fashion.

  6. Incidence of macroscopically occult neoplasias in Barrett's esophagus: are random biopsies dispensable in the era of advanced endoscopic imaging?

    PubMed

    Pohl, Juergen; Pech, Oliver; May, Andrea; Manner, Hendrik; Fissler-Eckhoff, Annette; Ell, Christian

    2010-11-01

    The gold standard for endoscopic surveillance of Barrett's esophagus (BE) includes targeted biopsies (TBs) from abnormalities as well as stepwise four-quadrant biopsies (4QBs) for detection of invisible high-grade intraepithelial neoplasias (HGINs) or early carcinomas (ECs). In a large mixed BE population, we investigated the rate of HGINs/ECs that are macroscopically occult to enhanced visualization with high-resolution endoscopy plus acetic acid chromoendoscopy. From January 2007 to December 2009, 701 consecutive BE patients were enrolled in a prospective study at a tertiary referral center. Of these, 406 patients had a history of HGIN/EC (high-risk group) and 295 patients did not (low-risk group). In 701 patients, 459 TBs and 5,485 4QBs were obtained. Altogether, 92 patients with 132 lesions containing HGINs/ECs were detected. For the diagnosis of HGINs/ECs, patient-related sensitivity and specificity rates of endoscopic imaging with TBs were 96.7 and 66.5%, with a positive and negative predictive value of 30.4 and 99.3%, respectively. In the high-risk group, 4QBs identified three additional patients (3.3%) with macroscopically occult HGINs/ECs. In the low-risk group, no HGINs/ECs were identified with either biopsy approach. Advanced endoscopic imaging identifies the vast majority of BE patients with early neoplasias, and the additive effect of 4QB is minimal. Therefore, in low- and high-risk patients, limiting endoscopic surveillance to guided biopsies is justified in specialized high-volume centers with permanent quality control. However, we do not advocate abandoning 4QB outside this setting.

  7. Endoscopy Assisted Oncoplastic Breast Surgery (EAOBS)

    PubMed Central

    Soybir, Gürsel; Fukuma, Eisuke

    2015-01-01

    Endoscopic oncoplastic breast surgery represents a minimal invasive approach with the aim of both removing cancer safely and also restoring the breast image. It has less noticeable scar, excellent cosmetic outcomes, high patient satisfaction rate and recently reported relatively long term safety. Operative techniques for both endoscopic breast conserving surgery and endoscopic nipple/areola/skin sparing mastectomy have been described in detail. Two different working planes in which one of them is subcutaneous and the other one is sub-mammary planes are being used during the surgery. Surgical techniqe needs some instruments such as endoscopic retractor, light guided specific mammary retractor, wound protector and bipolar scissor. Endoscopic breast retractors provide magnified visualization and extensive posterior dissection facility. Tunneling method and hydrodissection simplify the technique in the subcutaneous field. Oncoplastic reconstruction techniques are also applied after the tumor resection by endoscopic method. Complication rates of endoscopic breast surgery are similar to open breast surgery rates. Quite succesful local recurrence, distant metastasis and overall survival rates have been declared. However it looks reasonable to wait for the results with longer follow-up before having a judgement about oncologic efficiency and safety of the endoscopic breast cancer surgery. PMID:28331692

  8. Quantitative ENT endoscopy: the future in the new millennium

    NASA Astrophysics Data System (ADS)

    Mueller, Andreas; Schubert, Mario

    1999-06-01

    In Otorhinolaryngology the endoscopic appraisal of luminal dimensions of the nose, the throat, the larynx and the trachea is a daily problem. Those concerned with endoscopy know, that endoscopes distort dimensions of examined anatomical structures. To draw conclusions on luminal dimensions from the endoscopic pictures additional measuring devices are required. We developed a new method of measuring luminal dimensions in rigid or flexible endoscopy. For this a laser beam directed radially marks the anatomical lumen of interest in the videoendoscopic vision. The laser ring becomes deformed according to the form of the cavity explored. By keeping the distance defined between the laser ring and the top of the endoscope, the endoscopic video image can be measured. A piece of software developed by us calculates from the pictures the cross sectional area as well as the extension of benign or malign stenosis of the cavity explored. The result of the endoscopic measuring procedure can be visualized 3D on a PC-monitor. We are going to demonstrate the result of our clinical experience in different otorhinolaryngological diseases with the new endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic assisted manufacturing (EAM) of anatomical adapted stents, tubes and cannules.

  9. Mitigating fluorescence spectral overlap in wide-field endoscopic imaging

    PubMed Central

    Hou, Vivian; Nelson, Leonard Y.; Seibel, Eric J.

    2013-01-01

    Abstract. The number of molecular species suitable for multispectral fluorescence imaging is limited due to the overlap of the emission spectra of indicator fluorophores, e.g., dyes and nanoparticles. To remove fluorophore emission cross-talk in wide-field multispectral fluorescence molecular imaging, we evaluate three different solutions: (1) image stitching, (2) concurrent imaging with cross-talk ratio subtraction algorithm, and (3) frame-sequential imaging. A phantom with fluorophore emission cross-talk is fabricated, and a 1.2-mm ultrathin scanning fiber endoscope (SFE) is used to test and compare these approaches. Results show that fluorophore emission cross-talk could be successfully avoided or significantly reduced. Near term, the concurrent imaging method of wide-field multispectral fluorescence SFE is viable for early stage cancer detection and localization in vivo. Furthermore, a means to enhance exogenous fluorescence target-to-background ratio by the reduction of tissue autofluorescence background is demonstrated. PMID:23966226

  10. Advanced virtual endoscopy for endoscopic transsphenoidal pituitary surgery.

    PubMed

    Wolfsberger, Stefan; Neubauer, André; Bühler, Katja; Wegenkittl, Rainer; Czech, Thomas; Gentzsch, Stephan; Böcher-Schwarz, Hans-Gerd; Knosp, Engelbert

    2006-11-01

    Virtual endoscopy (vE) is the navigation of a camera through a virtual anatomical space that is computationally reconstructed from radiological image data. Inside this three-dimensional space, arbitrary movements and adaptations of viewing parameters are possible. Thereby, vE can be used for noninvasive diagnostic purposes and for simulation of surgical tasks. This article describes the development of an advanced system of vE for endoscopic transsphenoidal pituitary surgery and its application to teaching, training, and in the routine clinical setting. The vE system was applied to a series of 35 patients with pituitary pathology (32 adenomas, three Rathke's cleft cysts) operated endoscopically via the transsphenoidal route at the Department of Neurosurgery of the Medical University Vienna between 2004 and 2006. The virtual endoscopic images correlated well with the intraoperative view. For the transsphenoidal approach, vE improved intraoperative orientation by depicting anatomical landmarks and variations. For planning a safe and tailored opening of the sellar floor, transparent visualization of the pituitary adenoma and the normal gland in relation to the internal carotid arteries was useful. According to our experience, vE can be a valuable tool for endoscopic transsphenoidal pituitary surgery for training purposes and preoperative planning. For the novice, it can act as a simulator for endoscopic anatomy and for training surgical tasks. For the experienced pituitary surgeon, vE can depict the individual patient's anatomy, and may, therefore, improve intraoperative orientation. By prospectively visualizing unpredictable anatomical variations, vE may increase the safety of this surgical procedure.

  11. The universal serial bus endoscope: design and initial clinical experience.

    PubMed

    Hernandez-Zendejas, Gregorio; Dobke, Marek K; Guerrerosantos, Jose

    2004-01-01

    Endoscopic forehead lift is a well-established procedure in aesthetic plastic surgery. Many agree that currently available video-endoscopic equipment is bulky, multipieced and sometimes cumbersome in the operating theater. A novel system, the Universal Serial Bus Endoscope (USBE) was designed to simplify and reduce the number of necessary equipment pieces in the endoscopic setup. The USBE is attached by a single cable to a Universal Serial Bus (USB) port of a laptop computer. A built-in miniaturized cold light source provides illumination. A built-in digital camera chip enables procedure recording. The real-time images and movies obtained with USBE are displayed on the computer's screen and recorded on the laptop's hard disk drive. In this study, 25 patients underwent endoscopic browlift using the USBE system to test its clinical usefulness, all with good results and without complications or need for revision. The USBE was found to be reliable and easier to use than current video-endoscope equipment. The operative time needed to complete the procedure by the authors was reduced approximately 50%. The design and main technical characteristics of the USBE are presented.

  12. Epigastric hernia contiguous with the laparoscopic port site after endoscopic robotic total prostatectomy.

    PubMed

    Moriwaki, Yoshihiro; Otani, Jun; Okuda, Junzo; Maemoto, Ryo

    2018-03-23

    Both laparoscopic and endoscopic robotic surgery are widely accepted for many abdominal surgeries. However, the port site for the laparoscope cannot be easily sutured without defect, particularly in the cranial end; this can result in a port-site incisional hernia and trigger the progressive thinning and stretching of the linea alba, leading to epigastric hernia. In the present case, we encountered an epigastric hernia contiguous with an incisional scar at the port site from a previous endoscopic robotic total prostatectomy. Abdominal ultrasound and CT revealed that the width of the linea alba was 30-48 mm. Previous CT images prepared before endoscopic robotic prostatectomy had shown a thinning of the linea alba. We should be aware of the possibility of epigastric hernia after laparoscopic and endoscopic robotic surgery. In laparoscopic and endoscopic robotic surgery for a high-risk patient for epigastric hernia, we should consider additional sutures cranial to the port-site incision to prevent of an epigastric hernia. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  13. Urine Flow Dynamics Through Prostatic Urethra With Tubular Organ Modeling Using Endoscopic Imagery

    PubMed Central

    Kambara, Yoichi; Yamanishi, Tomonori; Naya, Yukio; Igarashi, Tatsuo

    2014-01-01

    Voiding dysfunction is common in the aged male population. However, the obstruction mechanism in the lower urinary tract and critical points for obstruction remains uncertain. The aim of this paper was to develop a system to investigate the relationship between voiding dysfunction and alteration of the shape of the prostatic urethra by processing endoscopic video images of the urethra and analyzing the fluid dynamics of the urine stream. A panoramic image of the prostatic urethra was generated from cystourethroscopic video images. A virtual 3-D model of the urethra was constructed using the luminance values in the image. Fluid dynamics using the constructed model was then calculated assuming a static urethra and maximum urine flow rate. Cystourethroscopic videos from 11 patients with benign prostatic hyperplasia were recorded around administration of an alpha-1 adrenoceptor antagonist. The calculated pressure loss through the prostatic urethra in each model corresponded to the prostatic volume, and the improvements of the pressure loss after treatment correlated to the conventional clinical indices. As shown by the proposed method, the shape of the prostatic urethra affects the transporting urine fluid energy, and this paper implies a possible method for detecting critical lesions responsible for voiding dysfunction. The proposed method provides critical information about deformation of the prostatic urethra on voiding function. Detailed differences in the various types of relaxants for the lower urinary tract could be estimated. PMID:27170869

  14. Toward real-time quantification of fluorescence molecular probes using target/background ratio for guiding biopsy and endoscopic therapy of esophageal neoplasia.

    PubMed

    Jiang, Yang; Gong, Yuanzheng; Rubenstein, Joel H; Wang, Thomas D; Seibel, Eric J

    2017-04-01

    Multimodal endoscopy using fluorescence molecular probes is a promising method of surveying the entire esophagus to detect cancer progression. Using the fluorescence ratio of a target compared to a surrounding background, a quantitative value is diagnostic for progression from Barrett's esophagus to high-grade dysplasia (HGD) and esophageal adenocarcinoma (EAC). However, current quantification of fluorescent images is done only after the endoscopic procedure. We developed a Chan-Vese-based algorithm to segment fluorescence targets, and subsequent morphological operations to generate background, thus calculating target/background (T/B) ratios, potentially to provide real-time guidance for biopsy and endoscopic therapy. With an initial processing speed of 2 fps and by calculating the T/B ratio for each frame, our method provides quasireal-time quantification of the molecular probe labeling to the endoscopist. Furthermore, an automatic computer-aided diagnosis algorithm can be applied to the recorded endoscopic video, and the overall T/B ratio is calculated for each patient. The receiver operating characteristic curve was employed to determine the threshold for classification of HGD/EAC using leave-one-out cross-validation. With 92% sensitivity and 75% specificity to classify HGD/EAC, our automatic algorithm shows promising results for a surveillance procedure to help manage esophageal cancer and other cancers inspected by endoscopy.

  15. Quantitative and qualitative analysis of the working area obtained by endoscope and microscope in pterional and orbitozigomatic approach to the basilar artery bifurcation using computed tomography based frameless stereotaxy: A cadaver study

    PubMed Central

    Filipce, Venko; Ammirati, Mario

    2015-01-01

    Objective: Basilar aneurisms are one of the most complex and challenging pathologies for neurosurgeons to treat. Endoscopy is a recently rediscovered neurosurgical technique that could lend itself well to overcome some of the vascular visualization challenges associated with this pathology. The purpose of this study was to quantify and compare the basilar artery (BA) bifurcation (tip of the basilar) working area afforded by the microscope and the endoscope using different approaches and image guidance. Materials and Methods: We performed a total of 9 dissections, including pterional (PT) and orbitozygomatic (OZ) approaches bilaterally in five whole, fresh cadaver heads. We used computed tomography based image guidance for intraoperative navigation as well as for quantitative measurements. We estimated the working area of the tip of the basilar, using both a rigid endoscope and an operating microscope. Operability was qualitatively assessed by the senior authors. Results: In microscopic exposure, the OZ approach provided greater working area (160 ± 34.3 mm2) compared to the PT approach (129.8 ± 37.6 mm2) (P > 0.05). The working area in both PT and OZ approaches using 0° and 30° endoscopes was larger than the one available using the microscope alone (P < 0.05). In the PT approach, both 0° and 30° endoscopes provided a working area greater than a microscopic OZ approach (P < 0.05) and an area comparable to the OZ endoscopic approach (P > 0.05). Conclusion: Integration of endoscope and microscope in both PT and OZ approaches can provide significantly greater surgical exposure of the BA bifurcation compared to that afforded by the conventional approaches alone. PMID:25972933

  16. [New guidelines on chronic pancreatitis : interdisciplinary treatment strategies].

    PubMed

    Lerch, M M; Bachmann, K A; Izbicki, J R

    2013-02-01

    Chronic pancreatitis is a common disorder associated with significant morbidity and mortality. Interdisciplinary consensus guidelines have recently updated the definitions and diagnostic criteria for chronic pancreatitis and provide a critical assessment of therapeutic procedures. Diagnostic imaging relies on endoscopic ultrasound (EUS) as the most sensitive technique, whereas computed tomography (CT) and magnetic resonance imaging (MRI)/magnetic resonance cholangiopancreatography (MRCP) remain a frequent preoperative requirement. Endoscopic retrograde cholangiopancreatography (ERCP) is now used mostly as a therapeutic procedure except for the differential diagnosis of autoimmune pancreatitis. Complications of chronic pancreatitis, such as pseudocysts, duct stricture and intractable pain can be treated with endoscopic interventions as well as open surgery. In the treatment of pseudocysts endoscopic drainage procedures now prevail while pain treatment has greater long-term effectiveness following surgical procedures. Currently, endocopic as well as surgical treatment of chronic pancreatitis require an ever increasing degree of technical and medical expertise and are provided increasingly more often by interdisciplinary centres. Surgical treatment is superior to interventional therapy regarding the outcome of pain control and duodenum-preserving pancreatic head resection is presently the surgical procedure of choice.

  17. [Three-dimensional endoscopic endonasal study of skull base anatomy].

    PubMed

    Abarca-Olivas, Javier; Monjas-Cánovas, Irene; López-Álvarez, Beatriz; Lloret-García, Jaime; Sanchez-del Campo, Jose; Gras-Albert, Juan Ramon; Moreno-López, Pedro

    2014-01-01

    Training in dissection of the paranasal sinuses and the skull base is essential for anatomical understanding and correct surgical techniques. Three-dimensional (3D) visualisation of endoscopic skull base anatomy increases spatial orientation and allows depth perception. To show endoscopic skull base anatomy based on the 3D technique. We performed endoscopic dissection in cadaveric specimens fixed with formalin and with the Thiel technique, both prepared using intravascular injection of coloured material. Endonasal approaches were performed with conventional 2D endoscopes. Then we applied the 3D anaglyph technique to illustrate the pictures in 3D. The most important anatomical structures and landmarks of the sellar region under endonasal endoscopic vision are illustrated in 3D images. The skull base consists of complex bony and neurovascular structures. Experience with cadaver dissection is essential to understand complex anatomy and develop surgical skills. A 3D view constitutes a useful tool for understanding skull base anatomy. Copyright © 2012 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  18. Central endoscopy reads in inflammatory bowel disease clinical trials: The role of the imaging core lab

    PubMed Central

    Ahmad, Harris; Berzin, Tyler M.; Yu, Hui Jing; Huang, Christopher S.; Mishkin, Daniel S.

    2014-01-01

    Clinical trials in inflammatory bowel disease (IBD) are evolving at a rapid pace by employing central reading for endoscopic mucosal assessment in a field that was, historically, largely based on assessments by local physicians. This transition from local to central reading carries with it numerous technical, operational, and scientific challenges, many of which can be resolved by imaging core laboratories (ICLs), a concept that has a longer history in clinical trials in a number of diseases outside the realm of gastroenterology. For IBD trials, ICLs have the dual goals of providing objective, consistent assessments of endoscopic findings using central-reading paradigms whilst providing important expertise with regard to operational issues and regulatory expectations. This review focuses on current approaches to using ICLs for central endoscopic reading in IBD trials. PMID:24994835

  19. Wide-field phase imaging for the endoscopic detection of dysplasia and early-stage esophageal cancer

    NASA Astrophysics Data System (ADS)

    Fitzpatrick, C. R. M.; Gordon, G. S. D.; Sawyer, T. W.; Wilkinson, T. D.; Bohndiek, S. E.

    2018-02-01

    Esophageal cancer has a 5-year survival rate below 20%, but can be curatively resected if it is detected early. At present, poor contrast for early lesions in white light imaging leads to a high miss rate in standard-of- care endoscopic surveillance. Early lesions in the esophagus, referred to as dysplasia, are characterized by an abundance of abnormal cells with enlarged nuclei. This tissue has a different refractive index profile to healthy tissue, which results in different light scattering properties and provides a source of endogenous contrast that can be exploited for advanced endoscopic imaging. For example, point measurements of such contrast can be made with scattering spectroscopy, while optical coherence tomography generates volumetric data. However, both require specialist interpretation for diagnostic decision making. We propose combining wide-field phase imaging with existing white light endoscopy in order to provide enhanced contrast for dysplasia and early-stage cancer in an image format that is familiar to endoscopists. Wide-field phase imaging in endoscopy can be achieved using coherent illumination combined with phase retrieval algorithms. Here, we present the design and simulation of a benchtop phase imaging system that is compatible with capsule endoscopy. We have undertaken preliminary optical modelling of the phase imaging setup, including aberration correction simulations and an investigation into distinguishing between different tissue phantom scattering coefficients. As our approach is based on phase retrieval rather than interferometry, it is feasible to realize a device with low-cost components for future clinical implementation.

  20. Morphologic 3D scanning of fallopian tubes to assist ovarian cancer diagnosis

    NASA Astrophysics Data System (ADS)

    Madore, Wendy-Julie; De Montigny, Etienne; Deschênes, Andréanne; Benboujja, Fouzi; Leduc, Mikael; Mes-Masson, Anne-Marie; Provencher, Diane M.; Rahimi, Kurosh; Boudoux, Caroline; Godbout, Nicolas

    2016-02-01

    Pathological evaluation of the fallopian tubes is an important diagnostic result but tumors can be missed using routine approaches. As the majority of high-grade serous ovarian cancers are now believed to originate in the fallopian tubes, pathological examination should include in a thorough examination of the excised ovaries and fallopian tubes. We present an dedicated imaging system for diagnostic exploration of human fallopian tubes. This system is based on optical coherence tomography (OCT), a laser imaging modality giving access to sub- epithelial tissue architecture. This system produces cross-sectional images up to 3 mm in depth, with a lateral resolution of ≍15μm and an axial resolution of ≍12μm. An endoscopic single fiber probe was developed to fit in a human fallopian tube. This 1.2 mm probe produces 3D volume data of the entire inner tube within a few minutes. To demonstrate the clinical potential of OCT for lesion identification, we studied 5 different ovarian lesions and healthy fallopian tubes. We imaged 52 paraffin-embedded human surgical specimens with a benchtop system and compared these images with histology slides. We also imaged and compared healthy oviducts from 3 animal models to find one resembling the human anatomy and to develop a functional ex vivo imaging procedure with the endoscopic probe. We also present an update on an ongoing clinical pilot study on women undergoing prophylactic or diagnostic surgery in which we image ex vivo fallopian tubes with the endoscopic probe.

  1. Endoscopic device for functional imaging of the retina

    NASA Astrophysics Data System (ADS)

    Barriga, Simon; Lohani, Sweyta; Martell, Bret; Soliz, Peter; Ts'o, Dan

    2011-03-01

    Non-invasive imaging of retinal function based on the recording of spatially distributed reflectance changes evoked by visual stimuli has to-date been performed primarily using modified commercial fundus cameras. We have constructed a prototype retinal functional imager, using a commercial endoscope (Storz) for the frontend optics, and a low-cost back-end that includes the needed dichroic beam splitter to separate the stimulus path from the imaging path. This device has been tested to demonstrate its performance for the delivery of adequate near infrared (NIR) illumination, intensity of the visual stimulus and reflectance return in the imaging path. The current device was found to be capable of imaging reflectance changes of 0.1%, similar to that observable using the modified commercial fundus camera approach. The visual stimulus (a 505nm spot of 0.5secs) was used with an interrogation illumination of 780nm, and a sequence of imaged captured. At each pixel, the imaged signal was subtracted and normalized by the baseline reflectance, so that the measurement was ΔR/R. The typical retinal activity signal observed had a ΔR/R of 0.3-1.0%. The noise levels were measured when no stimulus was applied and found to vary between +/- 0.05%. Functional imaging has been suggested as a means to provide objective information on retina function that may be a preclinical indicator of ocular diseases, such as age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy. The endoscopic approach promises to yield a significantly more economical retinal functional imaging device that would be clinically important.

  2. Virtual Interactive Presence in Global Surgical Education: International Collaboration Through Augmented Reality.

    PubMed

    Davis, Matthew Christopher; Can, Dang D; Pindrik, Jonathan; Rocque, Brandon G; Johnston, James M

    2016-02-01

    Technology allowing a remote, experienced surgeon to provide real-time guidance to local surgeons has great potential for training and capacity building in medical centers worldwide. Virtual interactive presence and augmented reality (VIPAR), an iPad-based tool, allows surgeons to provide long-distance, virtual assistance wherever a wireless internet connection is available. Local and remote surgeons view a composite image of video feeds at each station, allowing for intraoperative telecollaboration in real time. Local and remote stations were established in Ho Chi Minh City, Vietnam, and Birmingham, Alabama, as part of ongoing neurosurgical collaboration. Endoscopic third ventriculostomy with choroid plexus coagulation with VIPAR was used for subjective and objective evaluation of system performance. VIPAR allowed both surgeons to engage in complex visual and verbal communication during the procedure. Analysis of 5 video clips revealed video delay of 237 milliseconds (range, 93-391 milliseconds) relative to the audio signal. Excellent image resolution allowed the remote neurosurgeon to visualize all critical anatomy. The remote neurosurgeon could gesture to structures with no detectable difference in accuracy between stations, allowing for submillimeter precision. Fifteen endoscopic third ventriculostomy with choroid plexus coagulation procedures have been performed with the use of VIPAR between Vietnam and the United States, with no significant complications. 80% of these patients remain shunt-free. Evolving technologies that allow long-distance, intraoperative guidance, and knowledge transfer hold great potential for highly efficient international neurosurgical education. VIPAR is one example of an inexpensive, scalable platform for increasing global neurosurgical capacity. Efforts to create a network of Vietnamese neurosurgeons who use VIPAR for collaboration are underway. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. The cervical cancer detection system based on an endoscopic rotary probe

    NASA Astrophysics Data System (ADS)

    Yang, Yanshuang; Hou, Qiang; Zhao, Huijuan; Qin, Zhuanping; Gao, Feng

    2012-03-01

    To acquire the optical diffuse tomographic image of the cervix, a novel endoscopic rotary probe is designed and the frequency domain measurement system is developed. The finite element method and Gauss-Newton method are proposed to reconstruct the image of the phantom. In the optical diffuse tomographic imaging of the cervix, an endoscopic probe is needed and the detection of light at different separation to the irradiation spot is necessary. To simplify the system, only two optical fibers are adopted for light irradiation and collection, respectively. Two small stepper motors are employed to control the rotation of the incident fiber and the detection fiber, respectively. For one position of source fiber, the position of the detection fiber is changed from -61.875° to -50.625° and 50.625° to 61.875° to the source fiber, respectively. Then, the position of the source fiber is changed to another preconcerted position, which deviates the precious source position in an angle of 11.25°, and the detection fiber rotates within the above angles. To acquire the efficient irradiation and collection of the light, a gradient-index (GRIN) lens is connected at the head of the optical fiber. The other end of the GRIN lens is cut to 45°. With this design, light from optical fiber is reflected to the cervix wall, which is perpendicular to the optical fiber or vice versa. Considering the cervical size, the external diameter of the endoscopic probe is made to 20mm. A frequency domain (FD) near-infrared diffuse system is developed aiming at the detection of early cervical cancer, which modulates the light intensity in radio frequency and measures the amplitude attenuation and the phase delay of the diffused light using heterodyne detection. Phantom experiment results demonstrate that the endoscopic rotary scan probe and the system perform well in the endoscopic measurement.

  4. The Value of Intraoperative Magnetic Resonance Imaging in Endoscopic and Microsurgical Transsphenoidal Pituitary Adenoma Resection.

    PubMed

    Pal'a, Andrej; Knoll, Andreas; Brand, Christine; Etzrodt-Walter, Gwendolin; Coburger, Jan; Wirtz, Christian Rainer; Hlaváč, Michal

    2017-06-01

    The routine use of intraoperative magnetic resonance imaging (iMRI) helps to achieve gross total resection in transsphenoidal pituitary surgery. We compared the added value of iMRI for extent of resection in endoscopic versus microsurgical transsphenoidal adenomectomy. A total of 96 patients with pituitary adenoma were included. Twenty-eight consecutive patients underwent endoscopic transsphenoidal tumor resection. For comparison, we used a historic cohort of 68 consecutive patients treated microsurgically. We evaluated the additional resection after conducting iMRI using intraoperative and late postoperative volumetric tumor analysis 3 months after surgery. Demographic data, clinical symptoms, and complications as well as pituitary function were evaluated. We found significantly fewer additional resections after conducting iMRI in the endoscopic group (P = 0.042). The difference was even more profound in Knosp grade 0-2 adenomas (P = 0.029). There was no significant difference in Knosp grade 3-4 adenomas (P = 0.520). The endoscopic approach was associated with smaller intraoperative tumor volume (P = 0.023). No significant difference was found between both techniques in postoperative tumor volume (P = 0.228). Satisfactory results of pituitary function were significantly more often associated with an endoscopic approach in the multiple regression analysis (P = 0.007; odds ratio, 17.614; confidence interval 95%, 2.164-143.396). With the endoscopic approach, significantly more tumor volume reduction was achieved before conducting iMRI, decreasing the need for further resection. This finding was even more pronounced in adenomas graded Knosp 0-2. In the case of extensive and invasive adenomas with infiltration of cavernous sinus and suprasellar or parasellar extension, additional tumor resection and increase in the extent of resection was achieved with iMRI in both groups. The endoscopic approach seems to result in better endocrine outcomes, especially in Knosp grade 0-2 pituitary adenomas. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. [The recent news in endoscopic surgery: a review of the literature and meta-analysis].

    PubMed

    Klimenko, K É

    2012-01-01

    During a few recent years, endonasal surgery has become the principal tool for the operative treatment of many pathologies affecting the base of the skull. The present work was designed to estimate the possibilities of using endoscopic endonasal surgery to treat sinus and skull base lesions and illustrate the recent progress in the development of endoscopic equipment and instrumentation. The meta-analysis of the results of on-going research on the application of the endonasal endoscopic technology is described with the special emphasis on the plastic treatment of liquor fistulas, removal of juvenile nasopharyngeal angiofibromas, treatment of pathological changes in the clivial region and odontoid cervicomedullary junction.

  6. Simultaneous fingerprint and high-wavenumber fiber-optic Raman endoscopy for in vivo diagnosis of laryngeal cancer

    NASA Astrophysics Data System (ADS)

    Lin, Kan; Zheng, Wei; Wang, Jianfeng; Lim, Chwee Ming; Huang, Zhiwei

    2016-02-01

    We report a unique simultaneous fingerprint (FP) and high-wavenumber (HW) fiber-optic confocal Raman spectroscopy for in vivo diagnosis of laryngeal cancer in the head and neck under wide-field endoscopic imaging. The simultaneous FP and HW Raman endoscopy technique was performed on 21 patients and differentiated laryngeal carcinoma from normal tissues with both sensitivity and specificity of ~85%. This study shows the great potential of the FP/HW Raman endoscopic technique developed for in vivo diagnosis of laryngeal carcinoma during routine endoscopic examination.

  7. Dual-modality endoscopic probe for tissue surface shape reconstruction and hyperspectral imaging enabled by deep neural networks.

    PubMed

    Lin, Jianyu; Clancy, Neil T; Qi, Ji; Hu, Yang; Tatla, Taran; Stoyanov, Danail; Maier-Hein, Lena; Elson, Daniel S

    2018-06-15

    Surgical guidance and decision making could be improved with accurate and real-time measurement of intra-operative data including shape and spectral information of the tissue surface. In this work, a dual-modality endoscopic system has been proposed to enable tissue surface shape reconstruction and hyperspectral imaging (HSI). This system centers around a probe comprised of an incoherent fiber bundle, whose fiber arrangement is different at the two ends, and miniature imaging optics. For 3D reconstruction with structured light (SL), a light pattern formed of randomly distributed spots with different colors is projected onto the tissue surface, creating artificial texture. Pattern decoding with a Convolutional Neural Network (CNN) model and a customized feature descriptor enables real-time 3D surface reconstruction at approximately 12 frames per second (FPS). In HSI mode, spatially sparse hyperspectral signals from the tissue surface can be captured with a slit hyperspectral imager in a single snapshot. A CNN based super-resolution model, namely "super-spectral-resolution" network (SSRNet), has also been developed to estimate pixel-level dense hypercubes from the endoscope cameras standard RGB images and the sparse hyperspectral signals, at approximately 2 FPS. The probe, with a 2.1 mm diameter, enables the system to be used with endoscope working channels. Furthermore, since data acquisition in both modes can be accomplished in one snapshot, operation of this system in clinical applications is minimally affected by tissue surface movement and deformation. The whole apparatus has been validated on phantoms and tissue (ex vivo and in vivo), while initial measurements on patients during laryngeal surgery show its potential in real-world clinical applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Correlation of endoscopic optical coherence tomography with histology

    NASA Astrophysics Data System (ADS)

    Westphal, Volker; Rollins, Andrew M.; Willis, Joseph; Sivak, Michael J., Jr.; Izatt, Joseph A.

    2000-04-01

    Optical Coherence Tomography (OCT) is a noninvasive optical imaging technique that allows high-resolution cross- sectional imaging of tissue microstructure. We have recently developed a system for endoscopic OCT (EOCT) to examine the gastrointestinal tract of humans in vivo. Compared to endoscopic ultrasonic devices it offers a higher resolution and does not require coupling gels or fluids. EOCT may lead to a versatile tool for biopsy site selection or optical biopsy itself. The EOCT unit is comprised of an interferometer unit with a high speed scanning reference arm and an endoscopically compatible radially scanning probe as the sample arm. Fast data acquisition allows real-time display. Temporal averaging for speckle reduction and a transformation to correct nonlinear scanning were included in the EOCT control software, both in real-time. During in vivo clinical trials, we have observe the structure of the mucosa and submucosa in several gastrointestinal organs as well as glands, blood vessels, pits, villi and crypts. The purpose of this study was to correlate images acquired in vitro with EOCT to corresponding histological sections. EOCT images were obtained on fresh specimens, which were then fixed in formalin and submitted for standard histology. Tissues examined were normal specimens, which were then fixed in formalin and submitted for standard histology. Tissues examined were normal specimens of stomach, ileum, colon and rectum. It was shown that he thickness of the mucosa correlates well with the first bright layer in EOCT. The R2-value was determined to be 0.69. The submucosa and the muscularis propria could be identified. Furthermore, we were able to show the effect of pressure on the tissue on the visible details in the EOCT images.

  9. Improved planning of endoscopic sinonasal surgery from 3-dimensional images with Osirix® and stereolithography.

    PubMed

    Sánchez-Gómez, Serafín; Herrero-Salado, Tomás F; Maza-Solano, Juan M; Ropero-Romero, Francisco; González-García, Jaime; Ambrosiani-Fernández, Jesús

    2015-01-01

    The high variability of sinonasal anatomy requires the best knowledge of its three-dimensional (3D) conformation to perform surgery more safely and efficiently. The aim of the study was to validate the utility of Osirix® and stereolithography in improving endoscopic sinonasal surgery planning. Osirix® was used as a viewer and Digital Imaging and Communications in Medicine (DICOM) 3D imaging manager to improve planning for 114 sinonasal endoscopic operations with polyposis (86) and chronic rhinosinusitis (CRS) (28). Stereolithography rapid prototyping was used for 7 frontoethmoidal mucoceles. Using Osirix® and stereolithography, a greater number of anatomical structures were identified and this was done faster, with a statistically-significant clinical-radiological correlation (P<.01) compared with 2D CT plates. With a share of more than 75% of surgery performed by residents, surgical time was reduced by 38±12.3min in CRS and 42±27.9 in sinonasal polyposis. The fourth-year residents reached 100% surgical competence in critical surgical milestones with 16 surgeries (CI 12-19). The systematic use of Osirix® for visualisation and treatment of 3D sinonasal images from DICOM data files, along with the surgical team's ability to manipulate them as virtual reality, allows surgeons to perform endoscopic sinonasal surgery with greater confidence and in less time than using 2D images. Residents also achieve surgical competence faster, more safely and with fewer complications. This beneficial impact is increased when the surgical team has stereolithography rapid prototyping in more complex cases. Copyright © 2014 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  10. Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers

    NASA Astrophysics Data System (ADS)

    Xie, Tuqiang; Xie, Huikai; Fedder, Gary K.; Pan, Yingtian

    2003-11-01

    Experimental results of a modified micromachined microelectromechanical systems (MEMS) mirror for substantial enhancement of the transverse laser scanning performance of endoscopic optical coherence tomography (EOCT) are presented. Image distortion due to buckling of MEMS mirror in our previous designs was analyzed and found to be attributed to excessive internal stress of the transverse bimorph meshes. The modified MEMS mirror completely eliminates bimorph stress and the resultant buckling effect, which increases the wobbling-free angular optical actuation to greater than 37°, exceeding the transverse laser scanning requirements for EOCT and confocal endoscopy. The new optical coherence tomography (OCT) endoscope allows for two-dimensional cross-sectional imaging that covers an area of 4.2 mm × 2.8 mm (limited by scope size) and at roughly 5 frames/s instead of the previous area size of 2.9 mm × 2.8 mm and is highly suitable for noninvasive and high-resolution imaging diagnosis of epithelial lesions in vivo. EOCT images of normal rat bladders and rat bladder cancers are compared with the same cross sections acquired with conventional bench-top OCT. The results clearly demonstrate the potential of EOCT for in vivo imaging diagnosis and precise guidance for excisional biopsy of early bladder cancers.

  11. Augmented Endoscopic Images Overlaying Shape Changes in Bone Cutting Procedures.

    PubMed

    Nakao, Megumi; Endo, Shota; Nakao, Shinichi; Yoshida, Munehito; Matsuda, Tetsuya

    2016-01-01

    In microendoscopic discectomy for spinal disorders, bone cutting procedures are performed in tight spaces while observing a small portion of the target structures. Although optical tracking systems are able to measure the tip of the surgical tool during surgery, the poor shape information available during surgery makes accurate cutting difficult, even if preoperative computed tomography and magnetic resonance images are used for reference. Shape estimation and visualization of the target structures are essential for accurate cutting. However, time-varying shape changes during cutting procedures are still challenging issues for intraoperative navigation. This paper introduces a concept of endoscopic image augmentation that overlays shape changes to support bone cutting procedures. This framework handles the history of the location of the measured drill tip as a volume label and visualizes the remains to be cut overlaid on the endoscopic image in real time. A cutting experiment was performed with volunteers, and the feasibility of this concept was examined using a clinical navigation system. The efficacy of the cutting aid was evaluated with respect to the shape similarity, total moved distance of a cutting tool, and required cutting time. The results of the experiments showed that cutting performance was significantly improved by the proposed framework.

  12. High-speed imaging with endoscopic optical coherence tomography using bending vibration of optical fiber

    NASA Astrophysics Data System (ADS)

    Isago, Ryoichi; Nakamura, Kentaro

    2009-10-01

    In this report, we propose an endoscopic scanner head for optical coherence tomography (OCT) using bending vibration of an optical fiber. The optical fiber is attached to the center of a cylindrical piezoelectric actuator with four outer electrodes, and the voltages with the phase shift of π/2 are applied to the electrodes to excite a circular vibration of the fiber end. The output light from the fiber end is collimated by a lens, and deflected by 90 degrees using a cone mirror. The collimated light is scanned along the circumference of the endoscope due to the vibration of the optical fiber end. We made a prototype scanner head of 7.0 mm in outer diameter, and demonstrated tomographic imaging of tubular objects. The circumferential scan is carried out at 1 kHz which is the frequency of the fiber vibration, while the radial (depth) scan is performed at 20 kHz by the wavelength sweep of the light source. Two-dimensional OCT images were obtained in a short measuring time of 5 ms (flame rate of 200 fps), and three-dimensional dynamic imaging were demonstrated.

  13. Endoscopic trans-nasal approach for biopsy of orbital tumours using image-guided neuro-navigation system.

    PubMed

    Sieskiewicz, A; Lyson, T; Mariak, Z; Rogowski, M

    2008-05-01

    Histopathological diagnosis of intraorbital tumours is of crucial value for planning further therapy. The aim of the study was to explore clinical utility of image-guided endoscopy for biopsy of orbital tumours. Trans-nasal endoscopic biopsy of intraorbital mass lesions was performed in 6 patients using a neuro-navigation system (Medtronic Stealth Station Treon plus). The CT and MRI 1 mm slice images were fused by the system in order to visualise both bony and soft tissue structures. The anatomic fiducial registration protocol was used during the procedure. All lesions were precisely localised and the biopsies could be taken from the representative part of the pathological mass. None of the patients developed aggravation of ocular symptoms after the procedure. The operative corridor as well as the size of orbital wall fenestration could be limited to a minimum. The accuracy of neuro-navigation remained high and stable during the entire procedure. The image-guided neuro-navigation system facilitated endoscopic localisation and biopsy of intraorbital tumours and contributed to the reduction of surgical trauma during the procedure. The technique was particularly useful in small, medially located, retrobulbar tumours and in unclear situations when the structure of the lesion resembled surrounding intraorbital tissue.

  14. Miniature, minimally invasive, tunable endoscope for investigation of the middle ear.

    PubMed

    Pawlowski, Michal E; Shrestha, Sebina; Park, Jesung; Applegate, Brian E; Oghalai, John S; Tkaczyk, Tomasz S

    2015-06-01

    We demonstrate a miniature, tunable, minimally invasive endoscope for diagnosis of the auditory system. The probe is designed to sharply image anatomical details of the middle ear without the need for physically adjusting the position of the distal end of the endoscope. This is achieved through the addition of an electrowetted, tunable, electronically-controlled lens to the optical train. Morphological imaging is enabled by scanning light emanating from an optical coherence tomography system. System performance was demonstrated by imaging part of the ossicular chain and wall of the middle ear cavity of a normal mouse. During the experiment, we electronically moved the plane of best focus from the incudo-stapedial joint to the stapedial artery. Repositioning the object plane allowed us to image anatomical details of the middle ear beyond the depth of field of a static optical system. We also demonstrated for the first time to our best knowledge, that an optical system with an electrowetted, tunable lens may be successfully employed to measure sound-induced vibrations within the auditory system by measuring the vibratory amplitude of the tympanic membrane in a normal mouse in response to pure tone stimuli.

  15. A design of endoscopic imaging system for hyper long pipeline based on wheeled pipe robot

    NASA Astrophysics Data System (ADS)

    Zheng, Dongtian; Tan, Haishu; Zhou, Fuqiang

    2017-03-01

    An endoscopic imaging system of hyper long pipeline is designed to acquire the inner surface image in advance for the hyper long pipeline detects measurement. The system consists of structured light sensors, pipe robots and control system. The pipe robot is in the form of wheel structure, with the sensor which is at the front of the vehicle body. The control system is at the tail of the vehicle body in the form of upper and lower computer. The sensor can be translated and scanned in three steps: walking, lifting and scanning, then the inner surface image can be acquired at a plurality of positions and different angles. The results of imaging experiments show that the system's transmission distance is longer, the acquisition angle is more diverse and the result is more comprehensive than the traditional imaging system, which lays an important foundation for later inner surface vision measurement.

  16. Toward Intraoperative Image-Guided Transoral Robotic Surgery

    PubMed Central

    Liu, Wen P.; Reaugamornrat, Sureerat; Deguet, Anton; Sorger, Jonathan M.; Siewerdsen, Jeffrey H.; Richmon, Jeremy; Taylor, Russell H.

    2014-01-01

    This paper presents the development and evaluation of video augmentation on the stereoscopic da Vinci S system with intraoperative image guidance for base of tongue tumor resection in transoral robotic surgery (TORS). Proposed workflow for image-guided TORS begins by identifying and segmenting critical oropharyngeal structures (e.g., the tumor and adjacent arteries and nerves) from preoperative computed tomography (CT) and/or magnetic resonance (MR) imaging. These preoperative planned data can be deformably registered to the intraoperative endoscopic view using mobile C-arm cone-beam computed tomography (CBCT) [1, 2]. Augmentation of TORS endoscopic video defining surgical targets and critical structures has the potential to improve navigation, spatial orientation, and confidence in tumor resection. Experiments in animal specimens achieved statistically significant improvement in target localization error when comparing the proposed image guidance system to simulated current practice. PMID:25525474

  17. Application of Convolutional Neural Networks in the Diagnosis of Helicobacter pylori Infection Based on Endoscopic Images.

    PubMed

    Shichijo, Satoki; Nomura, Shuhei; Aoyama, Kazuharu; Nishikawa, Yoshitaka; Miura, Motoi; Shinagawa, Takahide; Takiyama, Hirotoshi; Tanimoto, Tetsuya; Ishihara, Soichiro; Matsuo, Keigo; Tada, Tomohiro

    2017-11-01

    The role of artificial intelligence in the diagnosis of Helicobacter pylori gastritis based on endoscopic images has not been evaluated. We constructed a convolutional neural network (CNN), and evaluated its ability to diagnose H. pylori infection. A 22-layer, deep CNN was pre-trained and fine-tuned on a dataset of 32,208 images either positive or negative for H. pylori (first CNN). Another CNN was trained using images classified according to 8 anatomical locations (secondary CNN). A separate test data set (11,481 images from 397 patients) was evaluated by the CNN, and 23 endoscopists, independently. The sensitivity, specificity, accuracy, and diagnostic time were 81.9%, 83.4%, 83.1%, and 198s, respectively, for the first CNN, and 88.9%, 87.4%, 87.7%, and 194s, respectively, for the secondary CNN. These values for the 23 endoscopists were 79.0%, 83.2%, 82.4%, and 230±65min (85.2%, 89.3%, 88.6%, and 253±92min by 6 board-certified endoscopists), respectively. The secondary CNN had a significantly higher accuracy than endoscopists (by 5.3%; 95% CI, 0.3-10.2). H. pylori gastritis could be diagnosed based on endoscopic images using CNN with higher accuracy and in a considerably shorter time compared to manual diagnosis by endoscopists. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Coblation-assisted endonasal endoscopic resection of juvenile nasopharyngeal angiofibroma.

    PubMed

    Ye, L; Zhou, X; Li, J; Jin, J

    2011-09-01

    Juvenile nasopharyngeal angiofibroma may be successfully resected using endoscopic techniques. However, the use of coblation technology for such resection has not been described. This study aimed to document cases of Fisch class I juvenile nasopharyngeal angiofibroma with limited nasopharyngeal and nasal cavity extension, which were completely resected using an endoscopic coblation technique. We retrospectively studied 23 patients with juvenile nasopharyngeal angiofibroma who underwent resection with either traditional endoscopic instruments (n = 12) or coblation (n = 11). Intra-operative blood loss and overall operative time were recorded. The mean tumour resection time for coblation and traditional endoscopic instruments was 87 and 136 minutes, respectively (t = 9.962, p < 0.001). Mean intra-operative blood loss was 121 and 420 ml, respectively (t = 28.944, p < 0.001), a significant difference. Both techniques achieved complete tumour resection with minimal damage to adjacent tissues, and no recurrence in any patient. Coblation successfully achieves transnasal endoscopic resection of juvenile nasopharyngeal angiofibroma (Fisch class I), with good surgical margins and minimal blood loss.

  19. Dangers in the Use of Staplers in Liver Surgery

    PubMed Central

    Riga, Angela; Karanjia, Nariman

    2007-01-01

    The use of endoscopic vascular staplers has become common practice in recent years both in open and minimally invasive surgery. The technological advances, however, are not free of problems. In our practice, we have come across two cases where the Endopath ETS Flex 45 Endoscopic Articulating Linear Cutter failed with dangerous consequences. PMID:17999829

  20. Comparing the Roles of EUS, ERCP and MRCP in Idiopathic Acute Recurrent Pancreatitis

    PubMed Central

    Safari, Mohammad Taghi; Miri, Mohammad Bager; Ebadi, Shahram; Shahrokh, Shabnam; Alizadeh, Amir Houshang Mohammad

    2016-01-01

    Acute recurrent pancreatitis (ARP) is defined as more than two attacks of acute pancreatitis with complete or almost complete resolution of symptoms and signs of pancreatitis between episodes. The initial evaluation fails to detect the cause of ARP in 10%–30% of patients, whose condition is classified as idiopathic ARP. Endoscopic ultrasound (EUS) has gained increasing attention as a useful imaging modality for the pancreas and the extrahepatic biliary tree. The close proximity of the pancreas to the digestive tract allows EUS to obtain detailed images of this organ. This review aims to record pancreaticobiliary endoscopic ultrasound (EUS) and other imaging modalities in the clinical management of patients with idiopathic ARP. PMID:27375362

Top