Design of the computerized 3D endoscopic imaging system for delicate endoscopic surgery.
Song, Chul-Gyu; Kang, Jin U
2011-02-01
This paper describes a 3D endoscopic video system designed to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. In a comparison of the polarized and conventional electric shutter-type stereo imaging systems, the former was found to be superior in terms of both accuracy and speed for suturing and for the loop pass test. Among the groups performing loop passing and suturing, there was no significant difference in the task performance between the 2D and 3D modes, however, suturing was performed 15% (p < 0.05) faster in 3D mode by both groups. The results of our experiments show that the proposed 3D endoscopic system has a sufficiently wide viewing angle and zone for multi-viewing.
Gastric full-thickness suturing during EMR and for treatment of gastric-wall defects (with video).
von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel
2008-04-01
The endoscopic full-thickness Plicator device was initially developed to provide an endoscopic treatment option for patients with GERD. Because the endoscopic full-thickness Plicator enables rapid and easy placement of transmural sutures, comparable with surgical sutures, we used the Plicator device for endoscopic treatment or prevention of GI-wall defects. To describe the outcomes and complications of endoscopic full-thickness suturing during EMR and for the treatment of gastric-wall defects. A report of 4 cases treated with the endoscopic full-thickness suturing between June 2006 and April 2007. A large tertiary-referral center. Four subjects received endoscopic full-thickness suturing. The subjects were women, with a mean age of 67 years. Of the 4 subjects, 3 received endoscopic full-thickness suturing during or after an EMR. One subject received endoscopic full-thickness suturing for treatment of a fistula. Primary outcome measurements were clinical procedural success and procedure-related adverse events. The mean time for endoscopic full-thickness suturing was 15 minutes. In all cases, GI-wall patency was restored or ensured, and no procedure-related complications occurred. All subjects responded well to endoscopic full-thickness suturing. The resection of one GI stromal tumor was incomplete. Because of the Plicator's 60F distal-end diameter, endoscopic full-thickness suturing could only be performed with the patient under midazolam and propofol sedation. The durable Plicator suture might compromise the endoscopic follow-up after EMR. The endoscopic full-thickness Plicator permits rapid and easy placement of transmural sutures and seems to be a safe and effective alternative to surgical intervention to restore GI-wall defects or to ensure GI-wall patency during EMR procedures.
Mori, Hirohito; Kobara, Hideki; Fujihara, Shintaro; Nishiyama, Noriko; Rafiq, Kazi; Oryu, Makoto; Fujiwara, Masao; Suzuki, Yasuyuki; Masaki, Tsutomu
2014-02-01
Endoscopic full-thickness resection (EFTR) requires a reliable full-thickness suturing device and an endoscopic counter-traction device to prevent the collapse of the digestive tract. The present study aimed to assess the reliability of newly developed flexible endoscopy suturing devices and the feasibility of pure EFTR. A total of 30 EFTRs were performed and allocated to three groups (N = 10 for each group). The full-thickness sutures were placed using over-the-scope clips (OTSCs), hand-sewn sutures, or the Double-arm-bar Suturing System (DBSS). Air leak tests were conducted in the three groups. The times required for the placement of one OTSC suture and single-stitch simple interrupted sutures (hand-sewn and DBSS sutures, respectively) were also compared. All 30 full-thickness sutures were completely and successfully placed. Regarding the air leak tests, the Mann-Whitney U test showed significant differences between OTSC and hand-sewn sutures (p = 0.003). There was also a significant difference between OTSC and DBSS sutures (p = 0.023). There was no significant difference between hand-sewn and DBSS sutures (p = 0.542). A significant difference was found in the suture time for single-stitch simple interrupted sutures among the OTSC, hand-sewn, and DBSS sutures. The Mann-Whitney U test revealed a significant difference between OTSC and hand-sewn sutures (p = 0.0001). There was no significant difference between OTSC and DBSS sutures (p = 0.533), while a significant difference was found between hand-sewn and DBSS sutures (p = 0.0001). Pure EFTR is feasible if the mechanical counter traction system is used to expand a small operative field and DBSS is used to make full-thickness sutures. The high safety of full-thickness resection and full-thickness suturing allows for clinical applications of this method.
Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F
2017-04-01
The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Sharaiha, Reem Z; Kumta, Nikhil A; DeFilippis, Ersilia M; Dimaio, Christopher J; Gonzalez, Susana; Gonda, Tamas; Rogart, Jason; Siddiqui, Ali; Berg, Paul S; Samuels, Paul; Miller, Larry; Khashab, Mouen A; Saxena, Payal; Gaidhane, Monica R; Tyberg, Amy; Teixeira, Julio; Widmer, Jessica; Kedia, Prashant; Loren, David; Kahaleh, Michel; Sethi, Amrita
2016-01-01
To describe a multicenter experience using an endoscopic suturing device for management of gastrointestinal (GI) defects and stent anchorage. Endoscopic closure of GI defects including perforations, fistulas, and anastomotic leaks as well as stent anchorage has improved with technological advances. An endoscopic suturing device (OverStitch; Apollo Endosurgery Inc.) has been used. Retrospective study of consecutive patients who underwent endoscopic suturing for management of GI defects and/or stent anchorage were enrolled between March 2012 and January 2014 at multiple academic medical centers. Data regarding demographic information and outcomes including long-term success were collected. One hundred and twenty-two patients (mean age, 52.6 y; 64.2% females) underwent endoscopic suturing at 8 centers for stent anchorage (n=47; 38.5%), fistulas (n=40; 32.7%), leaks (n=15; 12.3%), and perforations (n=20; 16.4%). A total of 44.2% underwent prior therapy and 97.5% achieved technical success. Immediate clinical success was achieved in 79.5%. Long-term clinical success was noted in 78.8% with mean follow-up of 68 days. Clinical success was 91.4% in stent anchorage, 93% in perforations, 80% in fistulas, but only 27% in anastomotic leak closure. Endoscopic suturing for management of GI defects and stent anchoring is safe and efficacious. Stent migration after stent anchoring was reduced compared with published data. Long-term success without further intervention was achieved in the majority of patients. The role of endoscopic suturing for repair of anastomotic leaks remains unclear given limited success in this retrospective study.
Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan
2017-09-01
Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.
Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth
2018-02-01
Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2 = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2 = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.
Lui, T H
2015-01-01
Eckert and Davis grade 3 superior peroneal retinaculum injury is rare and the optimal treatment is not yet determined. A 57 year-old lady sprained her left ankle resulting in grade 3 injury of the superior peroneal retinaculum and was treated by endoscopic retinaculum reconstruction. The fracture healed and the peroneal tendons were stabilized. However, it was complicated by protusion of the suture anchors into the posterolateral ankle gutter. The implants were successfully removed endoscopically. Proper selection of the size and dimension of the suture anchor and preoperative planning with computed tomogram is important for usage of suture anchors in the lateral malleolus.
von Renteln, Daniel; Schmidt, Arthur; Vassiliou, Melina C; Gieselmann, Maria; Caca, Karel
2009-10-01
Secure endoscopic closure of transgastric natural orifice transluminal endoscopic surgery (NOTES) access is of paramount importance. The over-the-scope clip (OTSC) system has previously been shown to be effective for NOTES gastrotomy closure. To compare OTSC gastrotomy closure with surgical closure. Randomized, controlled animal study. Animal facility laboratory. Thirty-six female domestic pigs. Gastrotomies were created by using a needle-knife and an 18-mm balloon. The animals were subsequently randomized to either open surgical repair with interrupted sutures or endoscopic repair with 12-mm OTSCs. In addition, pressurized leak tests were performed in ex vivo specimens of 18-mm scalpel incisions closed with suture (n = 14) and of intact stomachs (n = 10). The mean time for endoscopic closure was 9.8 minutes (range 3-22, SD 5.5). No complications occurred during either type of gastrotomy closure. At necropsy, examination of all OTSC and surgical closures demonstrated complete sealing of gastrotomy sites without evidence of injury to adjacent organs. Pressurized leak tests showed a mean burst pressure of 83 mm Hg (range 30-140, SD 27) for OTSC closures and 67 mm Hg (range 30-130, SD 27.7) for surgical sutures. Ex vivo hand-sewn sutures of 18-mm gastrotomies (n = 14) exhibited a mean burst pressure of 65 mm Hg (range 20-140, SD 31) and intact ex vivo stomachs (n = 10) had a mean burst pressure of 126 mm Hg (range 90-170, SD 28). The burst pressure of ex vivo intact stomachs was significantly higher compared with OTSC closures (P < .01), in vivo surgical closures (P < .01), and ex vivo hand-sewn closures (P < .01). There was a trend toward higher burst pressures in the OTSC closures compared with surgical closures (P = .063) and ex vivo hand-sewn closures (P = .094). In vivo surgical closures demonstrated similar burst pressures compared with ex vivo hand-sewn closures (P = .848). Nonsurvival setting. Endoscopic closure by using the OTSC system is comparable to surgical closure in a nonsurvival porcine model. This technique is easy to perform and is suitable for NOTES gastrotomy closure.
3-D video techniques in endoscopic surgery.
Becker, H; Melzer, A; Schurr, M O; Buess, G
1993-02-01
Three-dimensional visualisation of the operative field is an important requisite for precise and fast handling of open surgical operations. Up to now it has only been possible to display a two-dimensional image on the monitor during endoscopic procedures. The increasing complexity of minimal invasive interventions requires endoscopic suturing and ligatures of larger vessels which are difficult to perform without the impression of space. Three-dimensional vision therefore may decrease the operative risk, accelerate interventions and widen the operative spectrum. In April 1992 a 3-D video system developed at the Nuclear Research Center Karlsruhe, Germany (IAI Institute) was applied in various animal experimental procedures and clinically in laparoscopic cholecystectomy. The system works with a single monitor and active high-speed shutter glasses. Our first trials with this new 3-D imaging system clearly showed a facilitation of complex surgical manoeuvres like mobilisation of organs, preparation in the deep space and suture techniques. The 3-D-system introduced in this article will enter the market in 1993 (Opticon Co., Karlsruhe, Germany.
Shao, Pengfei; Li, Pu; Ju, Xiaobing; Qin, Chao; Li, Jie; Lv, Qiang; Meng, Xiaoxin; Yin, Changjun
2015-02-01
To study the feasibility and safety of laparoscopic radical cystectomy with intracorporeal orthotopic ileal neobladder and to evaluate the role of endoscopic stapling in neobladder construction. Fifty-five patients with bladder cancer who underwent laparoscopic radical cystectomy were retrospectively examined. Extended pelvic lymph node dissection was performed before cystectomy. An ileal segment of 50 cm was harvested to construct a U-shaped reservoir. The bottom of the reservoir was anastomosed with the posterior urethra. Twenty-five patients underwent neobladder construction by manual suturing and 30 patients by endoscopic stapler suturing. The mean operative time was 346 minutes, and mean neobladder construction time was 230 minutes. The median estimated blood loss was 500 mL, and 17 patients received intraoperative transfusion. Postoperative complications included 2 cases of urine leakage, 7 cases of pyelonephritis, 4 cases of incomplete bowel obstruction, 1 case of anastomotic stricture, and 1 case of death. Endoscopic stapler suturing for neobladder construction took significantly less time than manual suturing. However, neobladder stones were found in 2 patients who underwent operation using endoscopic suturing, and the stones were removed cystoscopically. The functional outcomes of the 2 constructive methods were comparable. Laparoscopic radical cystectomy with intracorporeal orthotopic neobladder is safe and feasible for experienced laparoscopic surgeons. Application of endoscopic stapler simplifies the surgical procedure while increasing the risk of neobladder stone formation. Copyright © 2015 Elsevier Inc. All rights reserved.
Chang, Victoria C; Tang, Shou-Jiang; Swain, C Paul; Bergs, Richard; Paramo, Juan; Hogg, Deborah C; Fernandez, Raul; Cadeddu, Jeffrey A; Scott, Daniel J
2013-08-01
The influence of endoscopic video camera (VC) image quality on surgical performance has not been studied. Flexible endoscopes are used as substitutes for laparoscopes in natural orifice translumenal endoscopic surgery (NOTES), but their optics are originally designed for intralumenal use. Manipulable wired or wireless independent VCs might offer advantages for NOTES but are still under development. To measure the optical characteristics of 4 VC systems and to compare their impact on the performance of surgical suturing tasks. VC systems included a laparoscope (Storz 10 mm), a flexible endoscope (Olympus GIF 160), and 2 prototype deployable cameras (magnetic anchoring and guidance system [MAGS] Camera and PillCam). In a randomized fashion, the 4 systems were evaluated regarding standardized optical characteristics and surgical manipulations of previously validated ex vivo (fundamentals of laparoscopic surgery model) and in vivo (live porcine Nissen model) tasks; objective metrics (time and errors/precision) and combined surgeon (n = 2) performance were recorded. Subtle differences were detected for color tests, and field of view was variable (65°-115°). Suitable resolution was detected up to 10 cm for the laparoscope and MAGS camera but only at closer distances for the endoscope and PillCam. Compared with the laparoscope, surgical suturing performances were modestly lower for the MAGS camera and significantly lower for the endoscope (ex vivo) and PillCam (ex vivo and in vivo). This study documented distinct differences in VC systems that may be used for NOTES in terms of both optical characteristics and surgical performance. Additional work is warranted to optimize cameras for NOTES. Deployable systems may be especially well suited for this purpose.
Study of insertion force and deformation for suturing with precurved NiTi guidewire.
Wang, Yancheng; Chen, Roland K; Tai, Bruce L; Xu, Kai; Shih, Albert J
2015-04-01
This research presents an experimental study evaluating stomach suturing using a precurved nickel-titanium (NiTi) guidewire for an endoscopic minimally invasive obesity treatment. Precise path planning is critical for accurate and effective suturing. A position measurement system utilizing a hand-held magnetic sensor was used to measure the shape of a precurved guidewire and to determine the radius of curvature before and after suturing. Ex vivo stomach suturing experiments using four different guidewire tip designs varying the radius of curvature and bevel angles were conducted. The changes in radius of curvature and suturing force during suturing were measured. A model was developed to predict the guidewire radius of curvature based on the measured suturing force. Results show that a small bevel angle and a large radius of curvature reduce the suturing force and the combination of small bevel angle and small radius of curvature can maintain the shape of guidewire for accurate suturing.
Endoscopic full-thickness resection of gastric subepithelial tumors: a single-center series.
Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; von Renteln, Daniel; Muehleisen, Helmut; Caca, Karel
2015-02-01
Endoscopic full-thickness resection of gastric subepithelial tumors with a full-thickness suturing device has been described as feasible in two small case series. The aim of this study was to evaluate the efficacy, safety, and clinical outcome of this resection technique. After 31 patients underwent endoscopic full-thickness resection, the data were analyzed retrospectively. Before snare resection, 1 to 3 full-thickness sutures were placed underneath each tumor with a device originally designed for endoscopic anti-reflux therapy. All tumors were resected successfully. Bleeding occurred in 12 patients (38.7 %); endoscopic hemostasis could be achieved in all cases. Perforation occurred in 3 patients (9.6 %), and all perforations could be managed endoscopically. Complete resection was histologically confirmed in 28 of 31 patients (90.3 %). Mean follow-up was 213 days (range, 1 - 1737), and no tumor recurrences were observed. Endoscopic full-thickness resection of gastric subepithelial tumors with the suturing technique described above is feasible and effective. After the resection of gastrointestinal stromal tumors (GISTs), we did not observe any recurrences during follow-up, indicating that endoscopic full-thickness resection may be an alternative to surgical resection for selected patients. © Georg Thieme Verlag KG Stuttgart · New York.
Endoscopic sleeve gastroplasty: the learning curve.
Hill, Christine; El Zein, Mohamad; Agnihotri, Abhishek; Dunlap, Margo; Chang, Angela; Agrawal, Alison; Barola, Sindhu; Ngamruengphong, Saowanee; Chen, Yen-I; Kalloo, Anthony N; Khashab, Mouen A; Kumbhari, Vivek
2017-09-01
Endoscopic sleeve gastroplasty (ESG) is gaining traction as a minimally invasive bariatric treatment. Concern that the learning curve may be slow, even among those proficient in endoscopic suturing, is a barrier to widespread implementation of the procedure. Therefore, we aimed to define the learning curve for ESG in a single endoscopist experienced in endoscopic suturing who participated in a 1-day ESG training program. Consecutive patients who underwent ESG between February 2016 and November 2016 were included. The performing endoscopist, who is proficient in endoscopic suturing for non-ESG procedures, participated in a 1-day ESG training session before offering ESG to patients. The outcome measurements were length of procedure (LOP) and number of plications per procedure. Nonlinear regression was used to determine the learning plateau and calculate the learning rate. Twenty-one consecutive patients (8 males), with mean age 47.7 ± 11.2 years and mean body mass index 41.8 ± 8.5 kg/m 2 underwent ESG. LOP decreased significantly across consecutive procedures, with a learning plateau at 101.5 minutes and a learning rate of 7 cases ( P = 0.04). The number of plications per procedure also decreased significantly across consecutive procedures, with a plateau at 8 sutures and a learning rate of 9 cases ( P < 0.001). Further, the average time per plication decreased significantly with consecutive procedures, reaching a plateau at 9 procedures ( P < 0.001). Endoscopists experienced in endoscopic suturing are expected to achieve a reduction in LOP and number of plications per procedure in successive cases, with progress plateauing at 7 and 9 cases, respectively.
Diana, M; Leroy, J; Wall, J; De Ruijter, V; Lindner, V; Dhumane, P; Mutter, D; Marescaux, J
2012-06-01
Endoluminal full-thickness closure of the rectal wall is critical in emerging procedures including endoscopic submucosal dissection and transrectal natural orifice transluminal endoscopic surgery (NOTES). This study aimed to compare manual suture using the transanal endoscopic operation platform (TEO; Karl Storz, Tüttlingen, Germany) with the end-to-end anastomosis hemorrhoid circular stapler (EEA; Covidien, Dublin, Ireland) for closure of the rectal viscerotomy during transrectal NOTES segmental colectomy. A total of 12 swine underwent transrectal hybrid NOTES partial colectomies. Animals were divided into two groups according to the viscerotomy closure technique: 1) TEO manual suture; 2) EEA circular stapler closure. Mean (± SD) viscerotomy closure time was 67.5 ± 59.5 minutes and 31.5 ± 19.6 minutes for TEO and EEA, respectively. There was one conversion to laparoscopy in the TEO group and a misfiring in the EEA group that required a TEO salvage suture. There was one positive air-leak test in each group. Peritoneal fluid collected at the end of the procedure tested positive for bacterial contamination in all cases. A mild stenosis was present in 4 /6 viscerotomies (67 %) in the TEO group and in 1/6 (17 %) in the EEA group on endoscopic control. Inflammatory changes were mild in 3/5 (60 %) and 4/5 (80 %) viscerotomies in the TEO and EEA groups, respectively, whereas severe inflammation was found in 2/5 (TEO) and 1 /5 (EEA). Transrectal viscerotomy closure using the EEA circular stapler technique is feasible, easy to perform, and histologically comparable to suture closure through a TEO platform. It may offer an attractive alternative for NOTES segmental colectomies and endoscopic resections. © Georg Thieme Verlag KG Stuttgart · New York.
[GERD: endoscopic antireflux therapies].
Caca, K
2006-08-02
A couple of minimally-invasive, endoscopic antireflux procedures have been developed during the last years. Beside endoscopic suturing these included injection/implantation technique of biopolymers and application of radiofrequency. Radiofrequency (Stretta) has proved only a very modest effect, while implantation techniques have been abandoned due to lack of long-term efficacy (Gatekeeper) or serious side effects (Enteryx). While first generation endoluminal suturing techniques (EndoCinch, ESD) demonstrated a proof of principle their lack of durability, due to suture loss, led to the development of a potentially durable transmural plication technique (Plicator). In a prospective-randomized, sham-controlled trial the Plicator procedure proved superiority concerning reflux symptoms, medication use and esophageal acid exposure (24-h-pH-metry). While long-term data have to be awaited to draw final conclusions, technical improvements will drive innovation in this field.
Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.
Bauder, Markus; Schmidt, Arthur; Caca, Karel
2016-04-01
Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.
Filip, Dobromir; Yadid-Pecht, Orly; Muench, Gregory; Mintchev, Martin P; Andrews, Christopher N
2013-02-01
Capsule endoscopy is a noninvasive method for examining the small intestine. Recently, this method has been used to visualize the colon. However, the capsule often tumbles in the wider colon lumen, resulting in potentially missed pathology. In addition, the capsule does not have the ability to distend collapsed segments of the organ. Self-stabilizing capsule endoscopy is a new method of visualizing the colon without tumbling and with the ability to passively distend colon walls. To quantitatively compare the detection rate of intraluminal suture marker lesions for colonoscopy by using a custom-modified, self-stabilizing capsule endoscope (SCE); an unmodified capsule endoscope (CE) of the same brand; and a standard colonoscope. Four mongrel dogs underwent laparotomy and the implantation of 5 to 8 suture markers to approximate colon lesions. Each dog had both capsule endoscopy and self-stabilizing capsule endoscopy, administered consecutively in random order. In each case, the capsule was inserted endoscopically into the proximal lumen of the colon followed by pharmacologically induced colon peristalsis to propel it distally through the colon. Blinded standard colonoscopy was performed by an experienced gastroenterologist after the capsule endoscopies. Experimental study in a live canine model. Four dogs. Laparotomy, capsule endoscopy, colonoscopy. Comparison of the marker detection rate of the SCE to that of the unmodified MiroCam CE and a colonoscope. The average percentages of the marker detection rate for unmodified capsule endoscopy, self-stabilizing capsule endoscopy, and colonoscopy, respectively, were 31.1%, 86%, and 100% (P < .01), with both self-stabilizing capsule endoscopy and colonoscopy performing significantly better than the unmodified capsule endoscopy. Acute canine model, suture markings poorly representative of epithelial polyps, limited number of animals. The proposed self-stabilizing capsule endoscope delivered a significant improvement in detection rates of colon suture markings when compared with the unmodified capsule endoscope. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Espinet Coll, Eduardo; Nebreda Durán, Javier; López-Nava Breviere, Gontrand; Galvao Neto, Manoel; Gómez Valero, José Antonio; Bacchiddu, Silvia; Vila Lolo, Carmen; Díaz Galán, Patricia; Bautista-Castaño, Inmaculada; Juan-Creix Comamala, Antonio
2018-05-09
many patients that undergo bariatric surgery (Roux-en-Y gastric bypass [RYGB]) may regain some of their weight lost over time. A transoral outlet reduction (TORe) with endoscopic suture could be a valid alternative in these patients. this was a retrospective initial series of 13 consecutive patients with weight regain after RYGB and a dilated gastro-jejunal anastomosis (> 15 mm). TORe was performed using an endoscopic transmural suture device (OverStitch-Apollo®), which was used to reduce the anastomosis aperture and also to treat the gastric pouch. The initial data of feasibility, safety and weight loss are described with a limited follow-up of six months. there was a mean maximum weight loss of 37.69 kg after RYGB and a subsequent average regain of 21.62 kg. The mean anastomosis diameter was 36 mm (range 20-45) which was reduced to 9 mm (range 5-12) (75% reduction), with an average of 2.5 sutures. The mean pouch size was 7.2 cm (range 2-10), which decreased to 4.7 cm (range 4-5) (34.72% reduction), with an average of 2.7 sutures. The mean weight loss six months after TORe was 12.29 kg, a weight loss of 56.85% of the weight regained after RYGB. No complications related to the procedure were recorded. endoscopic suture reduction of the dilated gastro-jejunal anastomosis and the gastric pouch seems a feasible and safe option in our limited initial experience. With a multidisciplinary approach and a short term follow-up, this seems to be a minimally invasive and effective option to control weight regain after RYGB.
Kyuno, Daisuke; Ohno, Keisuke; Katsuki, Shinichi; Fujita, Tomoki; Konno, Ai; Murakami, Takeshi; Waga, Eriko; Takanashi, Kunihiro; Kitaoka, Keisuke; Komatsu, Yuya; Sasaki, Kazuaki; Hirata, Koichi
2015-11-01
The use of endoscopic submucosal dissection (ESD) for duodenal neoplasms has increased in recent years, but delayed perforation and bleeding are also known to frequently occur. We present two cases in which duodenal adenoma was successfully treated with laparoscopic-endoscopic cooperative surgery. ESD was combined with laparoscopic seromuscular sutures. The lesions in both cases were located in the second portion of the duodenum. The patients requested resection of the lesion, and we performed laparoscopic-endoscopic cooperative surgery. After the laparoscopic surgeon mobilized the duodenum, the endoscopic surgeon performed ESD for the duodenal tumor without perforation. The laparoscopic surgeon sutured the duodenal wall in the seromuscular layer to strengthen the ulcer bed after ESD. Histopathological studies confirmed that the surgical margins were tumor-free in both cases. The patients were discharged with no complications. This unique laparoscopic-endoscopic cooperative procedure is a safe and effective method for resecting superficial nonampullary duodenal tumors. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
Huberty, Vincent; Machytka, Evzen; Boškoski, Ivo; Barea, Marie; Costamagna, Guido; Deviere, Jacques
2018-06-15
Obesity is the pandemic disease of this century. Surgery is the only effective treatment but cannot be offered to every patient. Endoscopic sutured gastroplasty is a minimally invasive technique that may potentially fill the gap between surgery and behavioral therapy. In this study, we prospectively investigated the efficacy and safety of a novel suturing device. After a pre-bariatric multidisciplinary work-up, class 1 and 2 obese patients were included. Using a simple triangulation platform, transmural sutures with serosa-to-serosa apposition were performed in the gastric cavity. Patients were followed according to the same routines as those performed for bariatric procedures. Between November 2015 and December 2016, 51 patients were included across three European Centers. Mean body mass index at baseline was 35.1 kg/m 2 (SD 3.0). Excess weight loss and total body weight loss at 1 year were 29 % (SD 28) and 7.4 % (SD 7), respectively, for the whole cohort (45 patients). At follow-up gastroscopy, 88 % of sutures were still in place (30 patients). No severe adverse events were observed. Endoscopic sutured gastroplasty using this novel device is safe and achieved weight loss results in line with criteria expected for these endoluminal techniques. Further prospective studies vs. placebo or nutritional support are needed. © Georg Thieme Verlag KG Stuttgart · New York.
Zwagerman, Nathan T; Geltzeiler, Mathew N; Wang, Eric W; Fernandez-Miranda, Juan C; Snyderman, Carl H; Gardner, Paul A
2018-05-30
We present a case of cerebrospinal fluid (CSF) leak after endoscopic endonasal resection of a large clival chordoma in an obese patient. The leak was at the lower reconstruction at the craniocervical junction and had failed repositioning. Using the V-Loc™ wound closure device (Covidien, New Haven, Connecticut) to suture the nasoseptal flap to the nasopharyngeal fascia, a water-tight seal was created and, along with a lumbar drain, the patient healed successfully.CSF leak after an endoscopic endonasal approach (EEA) to intradural pathologies remains one of the more common complications.1-4 Various closure techniques have been developed5-8 with success in mitigating this risk, but all have their limitations and rely on multiple layers including vascularized flaps like the nasoseptal flap.9-11 Endonasal suturing of graft materials offers the advantage of creating a water-tight seal. We present the use of the V-Loc™ wound closure device (Covidien) to successfully seal a postoperative CSF leak. The absorbable V-Loc™ wound closure device does not require the surgeon to tie knots, which is the most challenging step in a deep, 2-dimensional corridor. The suture is barbed and is anchored by threading the needle through a prefabricated loop at the end of the suture which locks in place. Each throw of the suture through tissue maintains the suture line as the barbs catch the tissue and prevent retraction. After successful closure, the needle can simply be cut off.The V-Loc™ wound closure device (Covidien) is a safe and effective adjunct to reconstruction after endoscopic endonasal skull base surgery as it provides an option for graft/flap suturing.A written release from the patient whose name or likeness is submitted as part of this Work is on file.
Moriwaki, Yoshihiro; Otani, Jun; Okuda, Junzo; Maemoto, Ryo
2018-03-23
Both laparoscopic and endoscopic robotic surgery are widely accepted for many abdominal surgeries. However, the port site for the laparoscope cannot be easily sutured without defect, particularly in the cranial end; this can result in a port-site incisional hernia and trigger the progressive thinning and stretching of the linea alba, leading to epigastric hernia. In the present case, we encountered an epigastric hernia contiguous with an incisional scar at the port site from a previous endoscopic robotic total prostatectomy. Abdominal ultrasound and CT revealed that the width of the linea alba was 30-48 mm. Previous CT images prepared before endoscopic robotic prostatectomy had shown a thinning of the linea alba. We should be aware of the possibility of epigastric hernia after laparoscopic and endoscopic robotic surgery. In laparoscopic and endoscopic robotic surgery for a high-risk patient for epigastric hernia, we should consider additional sutures cranial to the port-site incision to prevent of an epigastric hernia. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
Adam, Ahmed; Sookram, Jayveer
2018-01-01
Background To describe a novel bladder fixation technique for use during endoscopic vesicostomy button insertion. Methods After standard cystoscopic visualization of the bladder, a standard 18 G intravenous cannula was inserted into the bladder. A non-absorbable suture thread was placed through this intravenous cannula under cystoscopic vision. The proximal end of the suture was then removed using standard ureteroscopic grasping forceps (3 Fr) through another needle (15 G) inserted next to the initial puncture site (following a path at 30 degrees from the initial puncture tract) into the bladder. The suture ends were brought out of the bladder and tied at the skin level, 2 cm from the intended vesicostomy site. Sutures were removed on the second postoperative day. Results This fixation technique allows for adequate fixation of the bladder dome to the anterior abdominal wall. These sutures also have less potential for cutaneous scarring and pain. No complications were reported. Conclusion This simple fixation technique is easily performed using materials found in every urology suite. It also avoids the skills required with other previously reported fixation suture techniques, and can also be utilized for bladder fixation in cases of vesicoscopic laparoscopic or robotic assisted laparoscopic procedures. PMID:29692696
Myers, Christopher; Yellen, Benjamin; Evans, John; DeMaria, Eric; Pryor, Aurora
2010-05-01
To facilitate endolumenal and natural orifice procedures, this study evaluated a novel technique using external and endoscopically placed magnets to create suture-free gastroenteral anastomoses. Seven anesthetized adult swine underwent endoscopic placement of magnets into the small bowel and stomach. Using external magnets, the endoscopically placed internal magnets were brought into opposition under endoscopic view. After 1-2 weeks, the pigs were killed and analyzed. At laparotomy and under sterile conditions, peritoneal cultures were obtained. The anastomoses were evaluated endoscopically and tested using an air insufflation test. Finally, the anastomoses were resected and evaluated microscopically. The average operative time for endoscopic placement of the magnets was 34.3 +/- 14.8 min. Successful placement and creation of anastomoses occurred in six of the pigs. One pig did not form an anastomosis because the magnets were too large to pass through the pylorus at the time of attempted magnet placement. Six swine experienced uncomplicated postoperative courses. One pig's postoperative course involved constipation for several days, requiring additional fluids and fiber supplementation. The findings at endoscopy showed that the magnets were adhered to the anastomosis, which were easily freed, or within the stomach. The air insufflation test results were negative for all the pigs. At laparotomy, there was no evidence of infection, abscess, or leak, but two peritoneal culture results were positive with scant growth of Staphylococcus aureus and coagulase-negative staphylococcus, presumably contaminants. Microscopically, the anastomoses illustrated granulation and fibrous connective tissue without evidence of infection or leak. Endoscopically placed magnets with external magnet guidance is a feasible and novel approach to creating patent gastroenteral anastomoses without abdominal incisions or sutures.
Esophageal healing in the pony: comparison of sutured vs nonsutured esophagotomy.
Stick, J A; Krehbiel, J D; Kunze, D J; Wortman, J A
1981-09-01
Esophageal healing was evaluated in 10 ponies after sutured and nonsutured cervical esophagotomy techniques. Mucosal healing occurred significantly (P less than 0.005) faster after sutured esophagotomies (x = 7.5 days after surgery) than after nonsutured esophagotomies (x = 25.6 days after surgery), based on endoscopic and clinical evaluations. Although endoscopy was an accurate assessment of the return of normal passage of a food bolus through the esophagus, 4 of 10 ponies had radiographic evidence of a sinus tract after the mucosa was considered healed, based on endoscopic and clinical examinations. The surgical skin wound also healed significantly sooner after sutured esophagotomies (x = 10 days) than after nonsutured esophagotomies (x = 33.4 days). A traction diverticulum developed in all ponies with nonsutured esophagotomies, but occurred in only 1 pony with sutured esophagotomy. Minor complications were seen more frequently with sutured esophagotomy than with a nonsutured esophagotomy, but were resolved with local therapy. Saliva appeared to inhibit wound healing. All ponies were fed through esophagostomy tubes until the mucosa at the esophagotomy site was considered healed. Except for 1 sutured esophagotomy that dehisced, sutured esophagotomy was superior to nonsutured esophagotomy, because earlier establishment of a mucosal seal resulted in more rapid healing and reduced nursing care.
Huberty, Vincent; Ibrahim, Mostafa; Hiernaux, Martin; Chau, Alexandre; Dugardeyn, Sonia; Devière, Jacques
2017-04-01
Obesity is a major pandemic disease. Surgical therapy is highly effective, but its availability will likely be overwhelmed by the burden of the disease. Endoscopic technologies that could reproduce some of the clinical effects of surgery may become part of the treatment armamentarium. A simple transoral restrictive procedure could play a role in first-line surgical management. We evaluated the safety and feasibility of transmural suturing using a simple triangulation platform for gastric volume reduction through the creation of multiple double plicatures. Between May and July 2015, 11 obese (body mass index 34.6 ± 2.1 kg/m 2 ) patients (mean age, 36 ± 10 years) underwent gastroplasty through transmural endoscopic sutures (performed using a triangulation platform and an endoscopic stitcher). The median duration of the procedure was 2.00 hours (range, 1.15-3.15 hours) and dramatically decreased after the first 5 cases. No severe adverse events were observed. Mean (standard deviation) weight loss and percentage of excess weight loss were 5.8 kg (2.7%) and 21% (9%) at 1 month (n = 11), 8.8 kg (4.9%) and 33% (22%) at 3 months (n = 10), and 10.9 kg (7.3%) and 41% (33%) at 6 months (n = 10). Transoral endoscopic gastroplasty performed using a simple triangulation platform and a dedicated suturing device appears to be safe and effective at mid-term follow-up in creating gastric restriction and inducing weight loss in this first-in-humans experience. (Clinical trials registration number: NCT02534662.). Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Egi, H; Hattori, M; Tokunaga, M; Suzuki, T; Kawaguchi, K; Sawada, H; Ohdan, H
2013-01-01
The aim of this study was to determine whether any correlation exists between the performance of the Mimic® dV-Trainer (Mimic Technologies, Seattle, Wash., USA) and the da Vinci Surgical System (Intuitive Surgical, Sunnyvale, Calif., USA). Twelve participants were recruited, ranging from residents to consultants. We used four training tasks, consisting of 'Pick and Place', 'Peg Board', 'Thread the Rings' and 'Suture Sponge', from the software program of the Mimic dV-Trainer. The performance of the participants was recorded and measured. Additionally, we prepared the same tasks for the da Vinci Surgical System. All participants completed the tasks using the da Vinci Surgical System and were assessed according to time, the Objective Structured Assessment of Technical Skill checklist and the global rating score for endoscopic suturing assessed by two independent blinded observers. After performing these tasks, the participants completed a questionnaire that evaluated the Mimic dV-Trainer's face and content validity. The final results for each participant for the Mimic dV-Trainer and the da Vinci Surgical System were compared. All participants ranked the Mimic dV-Trainer as a realistic training platform that is useful for residency training. There was a significant relationship between the Mimic dV-Trainer and the da Vinci Surgical System in all four tasks. We verified the reliability of the assessment of the checklist and the global rating scores for endoscopic suturing assessed by the two blinded observers using Cronbach's alpha test (r = 0.803, 0.891). We evaluated the concurrent validity of the Mimic dV-Trainer and the da Vinci Surgical System. Our results suggest the possibility that training using the Mimic dV-Trainer may therefore be able to improve the operator's performance during live robot-assisted surgery. © 2013 S. Karger AG, Basel.
Van Rompaey, Jason; Bowers, Greg; Radhakrishnan, Jay; Panizza, Benedict; Solares, C Arturo
2014-06-01
Injury to the internal carotid artery is a feared complication of endoscopic endonasal surgery of the skull base. Such an event, although rare, is associated with high morbidity and mortality. Even if bleeding is controlled, permanent neurological defects frequently persist. Many techniques have been developed to manage internal carotid artery rupture with varying degrees of success. The purpose of this study was to explore endoscopic management of arterial damage with endovascular closure devices used for a femoral arteriotomy. The ability to remotely suture a damaged artery permits the possible adaptation of this technology in managing endoscopic arterial complications. Technical note. After the creation of an endoscopic endonasal corridor in a cadaveric specimen, an arteriotomy was created at the cavernous portion of the internal carotid artery. The Angio-Seal, StarClose, and MynxGrip vascular closure devices were utilized under endoscopic guidance to repair the arteriotomy. Angiography was then done on a cadaver sutured with the StarClose. Both the Angio-Seal and StarClose were deployed quickly and appeared to provide sufficient closure of the arteriotomy. The Angio-Seal required the use of a guidewire and was longer to deploy when compared with the StarClose. The StarClose deployment was quick and facile. The MynxGrip also deployed without difficulty. The Angio-Seal and StarClose systems were both successfully deployed utilizing an endoscopic endonasal approach. The MynxGrip was the easiest to deploy and has the greatest potential to be of benefit in this application. Further studies with hemodynamic models are required to properly assess the appropriateness in this setting. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Miyake, Toru; Sonoda, Hiromichi; Shimizu, Tomoharu; Ueki, Tomoyuki; Mori, Haruki; Takebayashi, Katsushi; Kaida, Sachiko; Yamaguchi, Tsuyoshi; Iida, Hiroya; Ban, Hiromitsu; Tani, Masaji
2018-04-01
It is hard to determine treatment strategy for radiation induced carcinoma, because radiation cause fibrosis to adjacent organ.The patient was in the 70's, who underwent 70 Gy radiation therapy for prostate cancer 5 years ago.He visited hospital because of fecal occult blood.Endoscopic examination revealed laterally spreading tumor(LST)in rectal front wall, and he referred to our hospital in purpose of endoscopic submucosal dissection(ESD).We performed ESD for LST, following transanal minimally invasive surgery to suture mucosal defect.He discharged out hospital 9 days after operation without any adverse event except anal pain.Suturing of mucosal defect after ESD might be potent to prevent postoperative complications in radiation induced rectal cancer.
Gallet, B; Zemour, G; Saudemont, J P; Renard, P; Hillion, M L; Hiltgen, M
1995-01-01
Systemic embolism is an unusual complication of endoscopic obturation of gastroesophageal varices with glue. This report describes a case of cerebral embolism after this procedure. Intracardiac glue within the left atrium was demonstrated by echocardiography. Cardiac fluoroscopy demonstrated an abnormal vessel connecting periesophageal veins with the right upper pulmonary vein. Cardiac surgery was performed. Intracardiac glue was removed and the entering orifice of the abnormal vessel in the right upper pulmonary vein was sutured. To our knowledge, this is the first reported case of intracardiac glue after variceal obturation. Echocardiography is useful in the diagnosis of this rare complication.
Chan, Garson; Mamut, Adiel; Martin, Paul; Welk, Blayne
2016-11-01
The objective of this study was to determine the outcomes associated with the endoscopic removal of foreign bodies (such as mesh or permanent suture) in the lower urinary tract after female stress incontinence surgery with the Holmium:YAG (Ho:YAG) laser, and to systematically review the literature on this topic. A retrospective chart review of 18 consecutive women found to have mesh or suture exposure was performed. All patients underwent Ho:YAG laser ablation. A systematic review was performed to identify literature addressing the endoscopic management of mesh/suture exposure after stress incontinence surgery. Between November 2011 and February 2016, 18 women underwent Ho:YAG laser ablation of exposed mesh or suture. Presenting symptoms included lower urinary tract symptoms, pelvic pain, incontinence, or recurrent urinary tract infections. Thirteen women had a previous synthetic midurethral sling and five had a prior retropubic suspension. The median age was 58 years (interquartile range [IQR] 50-60) and median follow-up was 2 years (IQR 1-2). Four patients (22%) had residual mesh after the first procedure, requiring a repeat endoscopic procedure. Only one patient had a small amount of asymptomatic residual mesh on cystoscopy after the final procedure. Only minor postoperative complications were observed. Eight patients had stress incontinence and four underwent operative treatment for this. In our systematic review, we identified 16 case series, which described a total of 158 patients. Women most commonly presented with voiding symptoms or incontinence. Based on the synthesis of these data, repeat procedures were necessary in 16% and vesicovaginal fistula occurred in 2%. Recurrent/persistent stress incontinence was present in 20%, and of these patients, 3/4 underwent a new stress incontinence procedure. Both our case series and the systematic review of the literature demonstrated that endoscopic treatment of lower urinary tract foreign bodies after stress incontinence surgery has good success rates and minimal morbidity.
NASA Astrophysics Data System (ADS)
Engelhardt, Sandy; Kolb, Silvio; De Simone, Raffaele; Karck, Matthias; Meinzer, Hans-Peter; Wolf, Ivo
2016-03-01
Mitral valve annuloplasty describes a surgical procedure where an artificial prosthesis is sutured onto the anatomical structure of the mitral annulus to re-establish the valve's functionality. Choosing an appropriate commercially available ring size and shape is a difficult decision the surgeon has to make intraoperatively according to his experience. In our augmented-reality framework, digitalized ring models are superimposed onto endoscopic image streams without using any additional hardware. To place the ring model on the proper position within the endoscopic image plane, a pose estimation is performed that depends on the localization of sutures placed by the surgeon around the leaflet origins and punctured through the stiffer structure of the annulus. In this work, the tissue penetration points are tracked by the real-time capable Lucas Kanade optical flow algorithm. The accuracy and robustness of this tracking algorithm is investigated with respect to the question whether outliers influence the subsequent pose estimation. Our results suggest that optical flow is very stable for a variety of different endoscopic scenes and tracking errors do not affect the position of the superimposed virtual objects in the scene, making this approach a viable candidate for annuloplasty augmented reality-enhanced decision support.
Timofeev, M E; Shapoval'yants, S G; Mikhalev, A I; Fedorov, E D; Konyukhov, G V
2016-01-01
To present the results of perforative duodenal ulcer surgical management using combination of endoscopic methods. The study included 279 patients with perforative duodenal ulcer who were operated for the period from 1996 to 2012. Diagnostics and medical tactics were based on developed in our clinic algorithm that includes use of both esophagogastroduodenoscopy and laparoscopy. Presented technique confirmed correct diagnosis, defined medical tactics and choice of surgery in 100% of cases. 67 patients had contraindications for laparoscopic suturing and underwent conventional operations. Herewith postoperative complications and death were observed in 25 (37.3%) and 9 (13.4%) patients respectively. Laparoscopic suturing was performed in 212 patients. Complications were diagnosed in 19 (8.9%) cases including 8 (3.7%) intraoperative and 11 (5.2%) postoperative. Deaths were absent.
Stier, Christine; Chiappetta, Sonja
2016-08-01
Dumping syndrome is a long-term postoperative complication of Roux-en-Y gastric bypass procedures. Morphologically, dumping syndrome usually correlates with a dilatation of the gastroenterostomy with accelerated pouch emptying. Conservative therapy includes diet changes, complementary pharmacotherapy and, if symptoms persist, surgical revision. Surgical options include endoscopic, endoluminal surgery to constrict the gastrojejunostomy using a novel endoscopic suturing device (OverStitch(TM), Apollo). In our study, we aimed to assess the viability, safety and efficacy of this procedure in patients with late dumping; 14 patients who had developed late dumping syndrome underwent surgery using an endoscopic suturing technique (OverStitch(TM), Apollo). Late dumping was confirmed by Sigstad score and an oral glucose tolerance test (OGTT). Prior to surgery, objective analysis of pouch emptying speed was assessed by gastric scintigraphy. Surgery was performed under general anaesthesia. None of the 14 patients suffered intra- or postoperative complications. No postsurgical increase in inflammation parameters was observed. The postinterventional pain scale (visual analogue scale) showed a mean score of 0.5 (range 0-10). In 13 of the 14 patients, no dumping was observed 1-month postsurgery. The postoperative Sigstad score (3.07 ± 2.06; range 1-9) showed an impressive reduction compared with the preoperative score (12.71 ± 4.18; range 7-24) (p < 0.001). Postoperative upper gastrointestinal gastrografin swallow revealed regular emptying in all the patients. The endoluminal endoscopic suturing technique-applied here for surgical revision of gastroenterostomy following Roux-en-Y gastric bypass-represents a promising, novel therapeutic option in late dumping syndrome involving minimal trauma and offering rapid reconvalescence.
A Common Bile Duct Stone formed by Suture Material after Open Cholecystectomy
Kim, Kook-Hyun; Jang, Byung-Ik
2007-01-01
The use of non-absorbable suture materials for cystic duct ligation after cholecystectomy can expose patients to the risk of recurrent stone formation in the common bile duct (CBD). However, in Korea suture materials have rarely been found to act as a nidus for common bile duct calculus formation. Recently, we experienced a case in which suture material, that had migrated from a previous cholecystectomy site into the CBD, probably served as a nidus for common bile duct stone formation. The stone was confirmed by endoscopic retrograde cholangiopancreatography (ERCP) and removed successfully using a basket. The authors report a case of surgical suture migration and discuss its subsequent role as a stone forming nucleus within the CBD in a patient who underwent open cholecystectomy; and include a review of the literature. PMID:18309688
Yang, Juliana; Siddiqui, Ali A; Kowalski, Thomas E; Loren, David E; Khalid, Ammara; Soomro, Ayesha; Mazhar, Syed M; Rosé, Julian; Isby, Laura; Kahaleh, Michel; Kalra, Ankush; Sarkisian, Alex M; Kumta, Nikhil A; Nieto, Jose; Sharaiha, Reem Z
2017-03-01
Endoscopic placement of fully covered self-expanding metal stents (FCSEMS) to treat malignant dysphagia in patients with esophageal cancer significantly improves dysphagia; however, these stents have a high migration rate. To determine whether FCSEMS fixation using an endoscopic suturing device treated malignant dysphagia and prevented stent migration in patients with locally advanced esophageal cancer receiving neoadjuvant therapy when compared to patients with FCSEMS placement alone. A review of patients with locally advanced esophageal cancer who underwent FCSEMS placement at 3 centers was performed. Patients were divided into two groups: Group A (n = 26) was composed of patients who underwent FCSEMS placement with suture placement, and Group B (n = 67) was composed of patients with FCSEMS placement alone. There were no significant differences between Groups A and B in demographics, and tumor characteristics. The technical success rate for stent placement was 100 %. There was no difference between Groups A and B in the median stent diameter and stent lengths. Mean dysphagia score obtained at 1 week after stent placement had improved significantly from baseline (2.4 and 1, respectively, p < 0.001). Patients had a median follow-up of 4 months. Immediate adverse events were mild chest discomfort in 4 patients in Group A and 2 patients in Group B (p = 0.05), and significant acid reflux in 3 patient in Group A compared to 2 patients in Group B (p = 0.1). The stent migration rate was significantly lower in Group A compared to compared to Group B (7.7 vs 26.9 %, respectively, p = 0.004). There was a delayed perforation in 1 patient and 1 death due to aspiration pneumonia in Group B. Fixation of esophageal FCSEMSs by using an endoscopic suturing device in patients receiving neoadjuvant therapy was shown to be feasible, safe, and relatively effective at preventing stent migration compared to those who had stent placed alone.
The history of barbed sutures.
Ruff, Gregory L
2013-09-01
Ligatures have been used for millennia to close wounds. Sterilization and synthetic polymers that degrade in a commensurate fashion with wound healing have been the most significant improvements in these age-old devices. However, the constricting loop of a traditional suture and subsequent ischemia ("approximate, don't strangulate") still account for the most common cause of wound dehiscence-necrosis. Inspired by the quill of the North American porcupine, I envisioned a bidirectional array of barbs that could secure tissue without relying on constricting loops. One set of barbs could anchor the other. In this article, I document the development process of these barbed sutures from concept to patent to manufacture and US Food and Drug Administration approval. Knotless, strong, and easy to place, barbed sutures could foreseeably supplant conventional sutures, particularly as endoscopic procedures become more common. They also offer the intriguing potential to suspend ptotic tissues without surgical intervention.
Image-based tracking of the suturing needle during laparoscopic interventions
NASA Astrophysics Data System (ADS)
Speidel, S.; Kroehnert, A.; Bodenstedt, S.; Kenngott, H.; Müller-Stich, B.; Dillmann, R.
2015-03-01
One of the most complex and difficult tasks for surgeons during minimally invasive interventions is suturing. A prerequisite to assist the suturing process is the tracking of the needle. The endoscopic images provide a rich source of information which can be used for needle tracking. In this paper, we present an image-based method for markerless needle tracking. The method uses a color-based and geometry-based segmentation to detect the needle. Once an initial needle detection is obtained, a region of interest enclosing the extracted needle contour is passed on to a reduced segmentation. It is evaluated with in vivo images from da Vinci interventions.
Per-oral endoscopic myotomy: Major advance in achalasia treatment and in endoscopic surgery
Friedel, David; Modayil, Rani; Stavropoulos, Stavros N
2014-01-01
Per-oral endoscopic myotomy (POEM) represents a natural orifice endoscopic surgery (NOTES) approach to laparoscopy Heller myotomy (LHM). POEM is arguably the most successful clinical application of NOTES. The growth of POEM from a single center in 2008 to approximately 60 centers worldwide in 2014 with several thousand procedures having been performed attests to the success of POEM. Initial efficacy, safety and acid reflux data suggest at least equivalence of POEM to LHM, the previous gold standard for achalasia therapy. Adjunctive techniques used in the West include impedance planimetry for real-time intraprocedural luminal assessment and endoscopic suturing for challenging mucosal defect closures during POEM. The impact of POEM extends beyond the realm of esophageal motility disorders as it is rapidly popularizing endoscopic submucosal dissection in the West and spawning offshoots that use the submucosal tunnel technique for a host of new indications ranging from resection of tumors to pyloromyotomy for gastroparesis. PMID:25548473
Traumatic thoracobiliary (pleurobiliary and bronchobiliary) fistula.
Andrade-Alegre, Rafael; Ruiz-Valdes, Maylin
2013-02-01
Traumatic thoracobiliary fistula is a rare but serious complication. A series of thoracobiliary fistulas secondary to penetrating trauma and analysis of trends in management are presented. We retrospectively reviewed all patients with traumatic thoracobiliary fistula, treated from April 2008 to February 2010. There were 5 patients: 4 suffered gunshot wounds and 1 was stabbed. The mean injury severity score was 22. Initial treatment was insertion of a chest tube in all cases. One patient underwent damage-control surgery and hepatic packing, and 3 were managed with laparotomy, a perihepatic closed drain, and suture of the diaphragm. Two patients developed bronchobiliary fistulas and 3 had pleurobiliary fistulas. Diagnostic procedures involved determination of bilirubin in pleural effusion, computed tomography, magnetic resonance cholangiography, hepatobiliary iminodiacetic scans, and endoscopic retrograde cholangiography. Definitive treatment included sphincterotomy and stenting in 4 cases, pulmonary decortication in 5, fistulectomy in 2, hepatic suture in 2, perihepatic closed drain placement in 4, and suture of the diaphragm in 4. Traumatic thoracobiliary fistulas are complex lesions. A multidisciplinary approach is required for a timely and successful outcome. Endoscopic retrograde cholangiography is very useful as the initial procedure to confirm the diagnosis and also for treatment.
Endoscopic diode laser welding of mucosal grafts on the larynx: a new technique.
Wang, Z; Pankratov, M M; Rebeiz, E E; Perrault, D F; Shapshay, S M
1995-01-01
Epithelial coverage of a laryngotracheal wound is an important factor in preventing stenosis, and endoscopic transplantation of a free mucosal graft without stents or sutures would be a significant therapeutic advance. In vitro and in vivo canine studies were performed to explore the feasibility of transplantation with a low-power diode laser (400 mW) enhanced by indocyanine green dye-doped albumin. The tensile strength of graft adherence in 10 cadaver larynges was strong (35.25 +/- 10.39 g). Survival studies in live canine models with a specially designed endoscopic instrument set showed excellent healing at 6, 14, and 28 days. Healing was documented with photography and by histologic examination. Successful endoscopic transplantation of a free mucosal graft should improve results of treatment for laryngotracheal stenosis and laryngeal reconstructive surgery.
Emam, T A; Hanna, G; Cuschieri, A
2002-02-01
Laparoscopic suturing is technically a demanding skill in laparoscopic surgery. Ergonomic experimental studies provide objective information on the important factors and variables that govern optimal endoscopic suturing. Our objective was to determine the optimum physical alignment, visual display, and direction of intracorporeal laparoscopic bowel suturing using infrared motion analysis and telemetric electromyography (EMG) systems. Ten surgeons participated in the study; each sutured 50-mm porcine small bowel enterotomies toward and away from the surgeon in the vertical and horizontal bowel plane with either isoplanar (image display corresponds with actual lie of the bowel) or nonisoplanar (bowel displayed horizontally but mounted vertically in the trainer and vice versa) display. The end points were the placement error score, execution time, leakage pressure, motion analysis, and telemetric EMG parameters of the surgeon's dominant upper limb. Suturing was demonstrably easier in the vertical than in the horizontal plane, resulting in a better task quality (placement error score, p < 0.0001; leakage pressure, p < 0.005) and shorter execution time (p < 0.05). Nonisoplanar display of the surgical anatomy degrades performance in terms of both task efficiency and task quality. On motion analysis, a wider angle of excursion and lower angular velocity were observed during the vertical suturing with isoplaner display. Compared to horizontal suturing, supination at the wrist was significantly greater during vertical than horizontal suturing (p < 0.05). Within each category (vertical vs horizontal suturing), the direction of suturing (toward/away from the surgeon) did not influence the extent of pronation/ supination at the wrist. In line with the degraded performance, significantly more muscle work was expended during horizontal suturing. This affected the forearm flexors (p < 0.05), arm flexors and extensors (p < 0.005 and p < 0.05, respectively), and deltoid muscles (p < 0.005) and was accompanied by significantly more fatigue in the related muscles. Small bowel enterotomies sutured toward the surgeon in both the vertical and the horizontal planes exhibited less placement error score than when sutured away from the surgeon, with no significant difference in the motion analysis and EMG parameters. Optimal laparoscopic suturing (better task quality and reduced execution time) is achieved with vertical suturing toward the surgeon with isoplanar monitor display of the operative field. The poorer task performance observed during horizontal suturing is accompanied by more muscle work and fatigue, and it is not improved by monitor display of the enterotomy in the vertical plane.
Endoscopic facelift of the frontal and temporal areas in multiple planes.
Hu, Xiaogen; Ma, Haihuan; Xue, Zhiqiang; Qi, Huijie; Chen, Bo
2017-02-01
The detachment planes used in endoscopic facelifts play an important role in determining the results of facial rejuvenation. In this study, we introduced the use of multiple detachment planes for endoscopic facelifts of the frontal and temporal areas, and examined its outcome. This study included 47 patients (38 female, 9 male) who requested frontal and temporal facelifts from January 2009 to January 2014. The technique of dissection in multiple planes was used for all 47 patients. In this technique, the frontal dissection was first carried out in the subgaleal plane, before being changed to the subperiosteal plane about 2 cm above the eyebrow line. Temporal dissection was carried out in both the subcutaneous and subgaleal planes. After detachment, frontal and temporal fixations were achieved using nonabsorbable sutures, and the incisions were closed. During follow-up (ranging from 6-24 months after surgery), the patients were shown their pre- and postoperative images, and asked to rate their satisfaction with the procedure. Complications encountered were documented. All 47 patients had complete recovery without any serious complications. The patient satisfaction rate was 93.6%. Minor complications included dimpling at the suture site, asymmetry, overcorrection, transitory paralysis, late oedema, haematoma, infection, scarring and hair loss. These complications resolved spontaneously and were negligible after complete recovery. Dissection in multiple planes is valuable in frontal and temporal endoscopic facelifts. It may be worthwhile to introduce the use of this technique in frontal and temporal facelifts, as it may lead to improved outcomes. Copyright: © Singapore Medical Association
Endoscopic treatment of prepatellar bursitis.
Huang, Yu-Chih; Yeh, Wen-Lin
2011-03-01
Operative treatment of prepatellar bursitis is indicated in intractable bursitis. The most common complication of surgical treatment for prepatellar bursitis is skin problems. For traumatic prepatellar bursitis, we propose a protocol of outpatient endoscopic surgery under local anaesthesia. From September 1996 to February 2001, 60 cases of failed nonoperative treatment for prepatellar bursitis were included. The average age was 33.5 ± 11.1 years (range 21-55). The average operation duration was 18 minutes. Two to three mini-arthroscopic portals were used in our series. No sutures or a simple suture was needed for the portals after operation. After follow-up for an average of 36.3 months, all patients are were symptom-free and had regained knee function. None of the population had local tenderness or hypo-aesthesia around their wound. Their radiographic and sonographic examinations showed no recurrence of bursitis. Outpatient arthroscopic bursectomy under local anaesthesia is an effective procedure for the treatment of post-traumatic prepatellar bursitis after failed conservative treatments. Both the cosmetic results and functional results were satisfactory.
Assessment of a simple, novel endoluminal method for gastrotomy closure in NOTES.
Lee, Sang Soo; Oelschlager, Brant K; Wright, Andrew S; Soares, Renato V; Sinan, Huseyin; Montenovo, Martin I; Hwang, Joo Ha
2011-10-01
A reliable method for gastrotomy closure in NOTES will be essential for NOTES to become viable clinically. However, methods using existing and widely available endoscopic accessories have been ineffective. The objective of this study was to evaluate the feasibility and safety of a new simple method for gastric closure (retracted clip-assisted loop closure) that uses existing endoscopic accessories with minor modifications. The retracted clip-assisted loop closure technique involves deploying 3-4 Resolution(®) clips (modified by attaching a 90-cm length of suture to the end of each clip) along the margin of the gastrotomy with one jaw on the serosal surface and the other jaw on the mucosal surface. The suture strings are threaded through an endoloop. Traction is then applied to the strings causing the gastric wall to tent. The endoloop is secured below the tip of the clips, completing a full-thickness gastrotomy closure. The main outcome measures were feasibility, efficacy, and safety of the new retracted clip-assisted loop closure technique for NOTES gastrotomy closure. An air-tight seal was achieved in 100% (n = 9) of stomachs. The mean leak pressure was 116.3 (±19.4) mmHg. The retracted clip-assisted loop closure technique can be used to perform NOTES gastrotomy closure by using existing endoscopic accessories with minor modifications.
Review of Pure Endoscopic Full-Thickness Resection of the Upper Gastrointestinal Tract
Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Masaki, Tsutomu
2015-01-01
Natural-orifice transluminal endoscopic surgery (NOTES) using flexible endoscopy has attracted attention as a minimally invasive surgical method that does not cause an operative wound on the body surface. However, minimizing the number of devices involved in endoscopic, compared to laparoscopic, surgeries has remained a challenge, causing endoscopic surgeries to gradually be phased out of use. If a flexible endoscopic full-thickness suturing device and a counter-traction device were developed to expand the surgical field for gastrointestinal-tract collapse, then endoscopic full-thickness resection using NOTES, which is seen as an extension of endoscopic submucosal dissection for full-thickness excision of tumors involving the gastrointestinal-tract wall, might become an extremely minimally invasive surgical method that could be used to resect only full-thickness lesions approached by the shortest distance via the mouth. It is expected that gastroenterological endoscopists will use this surgery if device development is advanced. This extremely minimally invasive surgery would have an immeasurable impact with regard to mitigating the burden on patients and reducing healthcare costs. Development of a new surgical method using a multipurpose flexible endoscope is therefore considered a socially urgent issue. PMID:26343069
Mosso, José L; Nieto, Jesus J; Carbajal, Manuel F; Marmolejo, Jorge; Ochoa, Enrique; De La Fuente, Mireya; Almazan, Andrew; Obrador, Tomas
2009-01-01
We present the smallest surgical trainer with a total weight of 400 gr, built in aluminum of 25 cm large and 24 cm wide, and 23 cm high. It's a system integrated by a small and open module, a lamp and a microcamera connected to a Head Mounted display. It holds two endoscopic instruments, and items to make knots or sutures and enhance visual-motor coordination. The vision we got is by a small microcamera displayed to a Head Mounted Display HMD. This surgical trainer is the smallest in the worldwide, easy to install, and easy to carry.
Lee, E C; Rafiq, A; Merrell, R; Ackerman, R; Dennerlein, J T
2005-08-01
Minimally invasive surgical techniques expose surgeons to a variety of occupational hazards that may promote musculoskeletal disorders. Telerobotic systems for minimally invasive surgery may help to reduce these stressors. The objective of this study was to compare manual and telerobotic endoscopic surgery in terms of postural and mental stress. Thirteen participants with no experience as primary surgeons in endoscopic surgery performed a set of simulated surgical tasks using two different techniques--a telerobotic master--slave system and a manual endoscopic surgery system. The tasks consisted of passing a soft spherical object through a series of parallel rings, suturing along a line 5-cm long, running a 32-in ribbon, and cannulation. The Job Strain Index (JSI) and Rapid Upper Limb Assessment (RULA) were used to quantify upper extremity exposure to postural and force risk factors. Task duration was quantified in seconds. A questionnaire provided measures of the participants' intuitiveness and mental stress. The JSI and RULA scores for all four tasks were significantly lower for the telerobotic technique than for the manual one. Task duration was significantly longer for telerobotic than for manual tasks. Participants reported that the telerobotic technique was as intuitive as, and no more stressful than, the manual technique. Given identical tasks, the time to completion is longer using the telerobotic technique than its manual counterpart. For the given simulated tasks in the laboratory setting, the better scores for the upper extremity postural analysis indicate that telerobotic surgery provides a more comfortable environment for the surgeon without any additional mental stress.
Tokuhara, Takaya; Nakata, Eiji; Tenjo, Toshiyuki; Kawai, Isao; Kondo, Keisaku; Ueda, Hirofumi; Tomioka, Atsushi
2018-01-01
We report an option for delta-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy (TLDG) for gastric cancer. We detail a single-layer suturing technique for the endoscopic linear stapler entry hole using knotless barbed sutures combined with the application of additional knotted sutures. From June 2013 to February 2017, we performed TLDG with delta-shaped gastroduodenostomy in 20 patients with gastric cancer. The linear stapler was closed and fired to attach the posterior walls of the remnant stomach and the duodenum together. After creating a good view of the greater curvature side of the entry hole for the stapler by retracting the knotted suture on the lesser curvature side toward the ventral side, we performed single-layer entire-thickness continuous suturing of this hole using a 15-cm-long barbed suture running from the greater curvature side to the lesser curvature side. We placed the second and third stitches between the seromuscular layer of the remnant stomach and the entire-thickness layer of the duodenum while suturing the duodenal mucosa as minutely as possible. In addition, we routinely added one or two entire-thickness knotted sutures at the site near the greater curvature side. We placed similar additional knotted sutures at the site with a broad pitch. TLDG with this reconstruction technique was successfully performed in all patients with no occurrences of anastomotic leakage or intraabdominal abscess around the anastomosis. It is suggested that this method can be one option for delta-shaped gastroduodenostomy in TLDG due to its cost-effectiveness and feasibility.
Tokuhara, Takaya; Nakata, Eiji; Tenjo, Toshiyuki; Kawai, Isao; Kondo, Keisaku; Ueda, Hirofumi; Tomioka, Atsushi
2018-01-01
We report an option for delta-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy (TLDG) for gastric cancer. We detail a single-layer suturing technique for the endoscopic linear stapler entry hole using knotless barbed sutures combined with the application of additional knotted sutures. From June 2013 to February 2017, we performed TLDG with delta-shaped gastroduodenostomy in 20 patients with gastric cancer. The linear stapler was closed and fired to attach the posterior walls of the remnant stomach and the duodenum together. After creating a good view of the greater curvature side of the entry hole for the stapler by retracting the knotted suture on the lesser curvature side toward the ventral side, we performed single-layer entire-thickness continuous suturing of this hole using a 15-cm-long barbed suture running from the greater curvature side to the lesser curvature side. We placed the second and third stitches between the seromuscular layer of the remnant stomach and the entire-thickness layer of the duodenum while suturing the duodenal mucosa as minutely as possible. In addition, we routinely added one or two entire-thickness knotted sutures at the site near the greater curvature side. We placed similar additional knotted sutures at the site with a broad pitch. TLDG with this reconstruction technique was successfully performed in all patients with no occurrences of anastomotic leakage or intraabdominal abscess around the anastomosis. It is suggested that this method can be one option for delta-shaped gastroduodenostomy in TLDG due to its cost-effectiveness and feasibility. PMID:29375711
Novel use of an ultrasonic bone-cutting device for endoscopic-assisted craniosynostosis surgery.
Chaichana, Kaisorn L; Jallo, George I; Dorafshar, Amir H; Ahn, Edward S
2013-07-01
Endoscopic-assisted craniosynostosis surgery is associated with less blood loss and shorter operative times as compared to open surgery. However, in infants who have low circulating blood volumes, the endoscopic approach is still associated with significant blood loss. A major source of blood loss is the bone that is cut during surgery. We discuss the novel use of an ultrasonic bone-cutting device for craniosynostosis surgery, which decreases bone bleeding. This device, which has primarily only been used for spine and skull base surgery, may help reduce blood loss in these infants. All patients with single suture craniosynostosis who were operated on with the use of an ultrasonic bone-cutting device were identified. The information retrospectively recorded from patient charts included patient age, suture involved, blood loss, operative times, complications, preoperative hemoglobin, postoperative hemoglobin, length of hospital stay, and follow-up times. Thirteen patients (12 males, 1 female) underwent surgery with an ultrasonic bone-cutting device during the reviewed period. The average age (±standard deviation) of the patients was 11.8 (±1.6) weeks. Four patients had metopic synostosis and nine patients had sagittal synostosis. The average surgery time was 84 (±13) min. The median (interquartile range) blood loss was 20 (10-70) cc. No patients required blood transfusions. Three patients had dural tears. We demonstrate the novel use of an ultrasonic bone-cutting device for endoscopic-assisted craniosynostosis surgery. This device limited blood loss while maintaining short operative times for infants with low circulating blood volumes.
[Perforated peptic ulcer closure: laparoscopic or open?
Alekberzade, A V; Krylov, N N; Rustamov, E A; Badalov, D A; Popovtsev, M A
To compare laparoscopic and open closure of perforated peptic ulcer (PPU). The study included 153 patients who underwent PPU suturing. 78 patients underwent laparoscopic closure (laparoscopic group) and open suturing via upper midline laparotomy was performed in 75 cases (open group). Surgery time, postoperative pain severity, time of analgesics intake, postoperative complications, hospital-stay and and cosmetic effect were compared. Laparoscopic PPU closure may be effective and accessible in experienced endoscopic surgeon. It significantly reduces postoperative pain severity, need for analgesics, incidence of postoperative complications and provides excellent cosmetic effect. However, there is greater time of surgery compared with open intervention. There were no significant differences in hspital-stay between groups. Laparoscopic PPU suturing can be considered a good alternative to open surgery. Further researches are needed for standardization, assessment of safety, real advantages and disadvantages of laparoscopic technique.
Lui, Tun Hing; Chang, Joseph Jeremy; Maffulli, Nicola
2016-03-01
Rerupture of the extensor hallucis longus tendon after primary repair and neglected rupture of the tendon poses surgical challenges to orthopedic surgeons. Open exploration and repair of the tendon ends usually requires large incision and extensive dissection. This may induce scarring and adhesion around the repaired tendon. Endoscopic-assisted repair has the advantage of minimally invasive surgery including less soft tissue trauma and scar formation and better cosmetic result. The use of Krackow locking suture and preservation of the extensor retinacula allow early mobilization of the great toe.
Evaluation of an endoscopically assisted gastropexy technique in dogs.
Dujowich, Mauricio; Reimer, S Brent
2008-04-01
To evaluate the use of endoscopy in conjunction with a gastropexy technique in dogs as a potential means to aid prevention of gastric dilatation-volvulus. 12 healthy adult medium- and large-breed dogs. 12 adult research dogs that had no abnormal physical examination findings each underwent an endoscopically assisted gastropexy procedure. On completion of the procedure, the dogs were euthanized and exploratory laparotomies were performed to evaluate the surgical site. Data recorded included anatomic location of the gastropexy, gastropexy length, and duration of procedure as well as any complications. Mean+/-SD gastropexy length was 3.3+/-0.25 cm, and mean duration of surgery was 18+/-7 minutes. In each dog, the stomach was located in its normal anatomic position and all gastropexies were sutured to the abdominal wall at the level of the pyloric antrum. The only complications during the procedure were needle bending and breakage at the time of stay suture placement. On the basis of these findings, it appears that endoscopically assisted gastropexy is a simple, fast, safe, and reliable method of performing a prophylactic gastropexy in dogs when undertaken by a person who is skilled in endoscopy. Such a procedure maximizes the benefits of decreased morbidity and shorter duration of anesthesia associated with minimally invasive surgery. Further clinical studies are warranted to evaluate the long-term efficacy of this procedure in dogs at risk for development of gastric dilatation-volvulus.
von Renteln, Daniel; Rudolph, Hans-Ulrich; Schmidt, Arthur; Vassiliou, Melina C; Caca, Karel
2010-01-01
Duodenal perforations during diagnostic upper endoscopy are rare; however, when therapeutic techniques are performed, the reported incidence is as great as 2.8%. Surgical repair is usually mandated, but it is associated with significant morbidity and mortality. To compare closure of duodenal perforations by using an over-the-scope clip (OTSC) with a surgical closure. Randomized, controlled animal study. Animal facility laboratory. Domestic pigs (24 females). Large (10-mm) duodenal perforations were created by using an endoscopic needle-knife. The animals were randomly assigned to either open surgical repair (n=12) or endoscopic closure by using the OTSC system (n=12). Pressurized leak tests were performed during necropsy. One major bleed occurred because of a liver injury during creation of the duodenotomy. Mean time for endoscopic closure was 5 minutes (range, 3-8 min; SD +/- 2). No complications occurred during any of the closure procedures. At necropsy, all OTSC and surgical closures demonstrated complete sealing of duodenotomy sites. Pressurized leak tests demonstrated a mean burst pressure of 166 mm Hg (range, 80-260; SD +/- 65) for OTSC closures and 143 mm Hg (range, 30-300, SD +/- 83) for surgical sutures. Ex vivo intact duodenal specimens exhibited a mean burst pressure of 247 mm Hg (range, 200-300; SD +/- 35), which was significantly higher compared with in vivo OTSC and surgical closures (P < .01). There were no significant differences between burst pressures of OTSC and surgical closures (P = .461). Nonsurvival setting. Endoscopic closure of duodenal perforations by using the OTSC system is comparable with surgical closure in a nonsurvival porcine model. This technique is easy to perform and seems suitable for repairing duodenal perforations. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Osera, Shozo; Yano, Tomonori; Odagaki, Tomoyuki; Oono, Yasuhiro; Ikematsu, Hiroaki; Ohtsu, Atsushi; Kaneko, Kazuhiro
2015-10-01
Percutaneous endoscopic gastrostomy (PEG) using the direct method is generally indicated for cancer patients. However, there are little available data about peritonitis related to this method. The aim of this retrospective analysis was to assess peritonitis related to PEG using the direct method in patients with cancer. We assessed the prevalence of peritonitis and the relationship between peritonitis and patients' backgrounds, as well as the clinical course after peritonitis. Between December 2008 and December 2011, peritonitis was found in 9 (2.1 %) of 421 patients. Of the 9 patients with peritonitis, 4 had received PEG prior to chemoradiotherapy. Emergency surgical drainage was required in 1 patient, and the remaining 8 recovered with conservative treatment. Peritonitis occurred within 8 days of PEG for 8 of the 9 patients and occurred within 2 days of suture removal for 4 of the 9 patients. Peritonitis related to PEG using the direct method was less frequent for cancer patients. Peritonitis tended to occur within a few days after removal of securing suture and in patients with palliative stage.
Jimbo, Takahiro; Ieiri, Satoshi; Obata, Satoshi; Uemura, Munenori; Souzaki, Ryota; Matsuoka, Noriyuki; Katayama, Tamotsu; Masumoto, Kouji; Hashizume, Makoto; Taguchi, Tomoaki
2015-10-01
Pediatric surgeons require highly advanced skills when performing endoscopic surgery; however, their experience is often limited in comparison to general surgeons. The aim of this study was to evaluate the effectiveness of endoscopic surgery training for less-experienced pediatric surgeons and then compare their skills before and after training. Young pediatric surgeons (n = 7) who participated in this study underwent a 2-day endoscopic skill training program, consisting of lectures, box training and live tissue training. The trainees performed the Nissen construction tasks before and after training using our objective evaluation system. A statistical analysis was conducted using the two-tailed paired Student's t tests. The time for task was 984 ± 220 s before training and 645 ± 92.8 s after training (p < 0.05). The total path length of both forceps was 37855 ± 10586 mm before training and 22582 ± 3045 mm after training (p < 0.05). The average velocity of both forceps was 26.1 ± 3.68 mm/s before training and 22.9 ± 2.47 mm/sec after training (p < 0.1). The right and left balance of suturing was improved after training (p < 0.05). Pediatric surgery trainees improved their surgical skills after receiving short-term training. We demonstrated the effectiveness of our training program, which utilized a new laparoscopic fundoplication simulator.
Josephson, Gary D; Black, Kaelan
2015-12-01
Literature review of treating the piriform apex sinus tract through microlaryngoscopy and a case description. Fourteen papers were identified in PubMed using the search criteria of piriform sinus fistula, microlaryngoscopic repair, and endoscopy. Institutional Review Board approval was obtained. One hundred forty-five cases including ours were available for review, with 182 procedures. Sixty-two cases were male, 73 female, and 10 genders were not reported. Multiple treatment options were used, including electrocautery, chemocautery, mass excision, fibrin glue, lasers, suture closure, or combination of stated modalities. Of the 182 procedures, 147 procedures were performed endoscopically. There were 37 recurrences (25%). These patients either underwent a repeat endoscopic procedure or an open excision. One hundred and ten (75%) endoscopic procedures were successful. Piriform sinus tract anomalies often present as a mass and recurrent neck infections. This review reveals that treating the internal piriform sinus opening alone can be successful. This procedure has low morbidity, short operative time, and high success. We advocate this approach first with a combined open/laryngoscopic approach for failed cases. To our knowledge, our technique of CO₂laser ablation of the tract followed by suture closure has not been previously described. We believe this to be the first comprehensive review of this topic and the largest series of cases included in a single report. © The Author(s) 2015.
NOTES: a review of the technical problems encountered and their solutions.
Mintz, Yoav; Horgan, Santiago; Cullen, John; Stuart, David; Falor, Eric; Talamini, Mark A
2008-08-01
Natural orifice translumenal endoscopic surgery (NOTES) is currently investigated and developed worldwide. In the past few years, multiple groups have confronted this challenge. Many technical problems are encountered in this technique due to the currently available tools for this approach. Some of the unique technical problems in NOTES include: blindly performed primary incisions; uncontrolled pneumoperitoneal pressure; no support for the endoscope in the abdominal cavity; inadequate vision; insufficient illumination; limited retraction and exposure; and the complexity of suturing and performing a safe anastomosis. In this paper, we review the problems encountered in NOTES and provide possible temporary solutions. Acute and survival studies were performed on 15 farm pigs. The hybrid technique approach (i.e., endoscopic surgery with the aid of laparoscopic vision) was performed in all cases. Procedures performed included liver biopsies, bilateral tubal ligation, oophprectomy, cholecystectomy, splenectomy and small bowel resection, and anastomosis. All attempted procedures were successfully performed. New methods and techniques were developed to overcome the technical problems. Closure of the gastrotomy was achieved by T-bar sutures and by stapler closure of the stomach incision. Small bowel anastomosis was achieved by the dual-lumen NOTES technique. The hybrid technique serves as a temporary approach to aid in developing the NOTES technique. A rectal or vaginal port of entry enables and facilitates gastrointestinal NOTES by using available laparoscopic instruments. The common operations performed today in the laparoscopic fashion could be probably performed in the NOTES approach. The safety of these procedures, however, is yet to be determined.
Song, Byeong Gu; Lee, Bong Eun; Jeon, Hye Kyung; Baek, Dong Hoon; Song, Geun Am
2017-01-01
Aims To investigate the feasibility and safety of endoscopic submucosal dissection (ESD) of gastric epithelial neoplasms in the remnant stomach (GEN-RS) after various types of partial gastrectomy. Methods This study included 29 patients (31 lesions) who underwent ESD for GEN-RS between March 2006 and August 2016. Clinicopathologic data were retrieved retrospectively to assess the therapeutic ESD outcomes, including en bloc and complete resection rates and procedure-related adverse events. Results The en bloc, complete, and curative resection rates were 90%, 77%, and 71%, respectively. The types of previous gastrectomy, tumor size, macroscopic type, and tumor histology were not associated with incomplete resection. Only tumors involving the suture lines from the prior partial gastrectomy were significantly associated with incomplete resection. The procedure-related bleeding and perforation rates were 6% and 3%, respectively; none of the adverse events required surgical intervention. During a median follow-up period of 25 months (range, 6–58 months), there was no recurrence in any case. Conclusions ESD is a safe and feasible treatment for GEN-RS regardless of the previous gastrectomy type. However, the complete resection rate decreases for lesions involving the suture lines. PMID:28592968
Natural orifice translumenal endoscopic surgery: Progress in humans since white paper
Santos, Byron F; Hungness, Eric S
2011-01-01
Since the first description of the concept of natural orifice translumenal endoscopic surgery (NOTES), a substantial number of clinical NOTES reports have appeared in the literature. This editorial reviews the available human data addressing research questions originally proposed by the white paper, including determining the optimal method of access for NOTES, developing safe methods of lumenal closure, suturing and anastomotic devices, advanced multitasking platforms, addressing the risk of infection, managing complications, addressing challenges with visualization, and training for NOTES procedures. An analysis of the literature reveals that so far transvaginal access and closure appear to be the most feasible techniques for NOTES, with a limited, but growing transgastric, transrectal, and transesophageal NOTES experience in humans. The theoretically increased risk of infection as a result of NOTES procedures has not been substantiated in transvaginal and transgastric procedures so far. Development of suturing and anastomotic devices and advanced platforms for NOTES has progressed slowly, with limited clinical data on their use so far. Data on the optimal management and incidence of intraoperative complications remain sparse, although possible factors contributing to complications are discussed. Finally, this editorial discusses the likely direction of future NOTES development and its possible role in clinical practice. PMID:21483624
Transcolonic Perirectal NOTES Access (PNA): A feasibility study with survival in swine model.
Oliveira, André L A; Zorron, Ricardo; Oliveira, Flavio M M DE; Santos, Marcelo B Dos; Scheffer, Jussara P; Rios, Marcelo; Antunes, Fernanda
2017-05-01
Transrectal access still has some unsolved issues such as spatial orientation, infection, access and site closure. This study presents a simple technique to perform transcolonic access with survival in a swine model series. A new technique for NOTES perirectal access to perform retroperitoneoscopy, peritoneoscopy, liver and lymphnode biopsies was performed in 6 pigs, using Totally NOTES technique. The specimens were extracted transanally. The flexible endoscope was inserted through a posterior transmural incision and the retrorectal space. Cultures of bacteria were documented for the retroperitoneal space and intra abdominal cavity after 14 days. Rectal site was closed using non-absorbable sutures. There was no bowel cleansing, nor preoperative fasting. The procedures were performed in 6 pigs through transcolonic natural orifice access using available endoscopic flexible instruments. All animals survived 14 days without complications, and cultures were negative. Histopathologic examination of the rectal closure site showed adequate healing of suture line and no micro abscesses. The results of feasibility and safety of experimental Transcolonic NOTES potentially brings new frontiers and future wider applications for minimally invasive surgery. The treatment of colorectal, abdominal and retroperitoneal diseases through a flexible Perirectal NOTES Access (PNA) is a promising new approach.
Dorman, Robert M; Vali, Kaveh; Harmon, Carroll M; Zaritzky, Mario; Bass, Kathryn D
2016-05-01
We describe the treatment of a patient with long-gap esophageal atresia with an upper pouch fistula, mircogastria and minimal distal esophageal remnant. After 4.5 months of feeding via gastrostomy, a proximal fistula was identified by bronchoscopy and a thoracoscopic modified Foker procedure was performed reducing the gap from approximately 7-5 cm over 2 weeks of traction. A second stage to ligate the fistula and suture approximate the proximal and distal esophagus resulted in a gap of 1.5 cm. IRB and FDA approval was then obtained for endoscopic placement of 10-French catheter mounted magnets in the proximal and distal pouches promoting a magnetic compression anastomosis (magnamosis). Magnetic coupling occurred at 4 days and after magnet removal at 13 days an esophagram demonstrated a 10 French channel without leak. Serial endoscopic balloon dilation has allowed drainage of swallowed secretions as the baby learns bottling behavior at home.
Liver transplantation with piggyback anastomosis using a linear stapler: a case report.
Akbulut, S; Wojcicki, M; Kayaalp, C; Yilmaz, S
2013-04-01
The so-called piggyback technique of liver transplantation (PB-LT) preserves the recipient's caval vein, shortening the warm ischemic time. It can be reduced even further by using a linear stapler for the cavocaval anastomosis. Herein, we have presented a case of a patient undergoing a side-to-side, whole-organ PB-LT for cryptogenic cirrhosis. Upper and lower orifices of the donor caval vein were closed at the back table using a running 5-0 polypropylene suture. Three stay sutures were then placed on caudal parts of both the recipient and donor caval with a 5-mm venotomies. The endoscopic linear stapler was placed upward through the orifices and fired. A second stapler was placed more cranially and fired resulting in a 8-9 cm long cavocavostomy. Some loose clips were flushed away from the caval lumen. The caval anastomosis was performed within 4 minutes; the time needed to close the caval vein stapler insertion orifices (4-0 polypropylene running suture) before reperfusion was 1 minute. All other anastomoses were performed as typically sutured. The presented technique enables one to reduce the warm ischemic time, which can be of particular importance with marginal grafts. Copyright © 2013 Elsevier Inc. All rights reserved.
Cutting thread at flexible endoscopy.
Gong, F; Swain, P; Kadirkamanathan, S; Hepworth, C; Laufer, J; Shelton, J; Mills, T
1996-12-01
New thread-cutting techniques were developed for use at flexible endoscopy. A guillotine was designed to follow and cut thread at the endoscope tip. A new method was developed for guiding suture cutters. Efficacy of Nd: YAG laser cutting of threads was studied. Experimental and clinical experience with thread-cutting methods is presented. A 2.4 mm diameter flexible thread-cutting guillotine was constructed featuring two lateral holes with sharp edges through which sutures to be cut are passed. Standard suture cutters were guided by backloading thread through the cutters extracorporeally. A snare cutter was constructed to retrieve objects sewn to tissue. Efficacy and speed of Nd: YAG laser in cutting twelve different threads were studied. The guillotine cut thread faster (p < 0.05) than standard suture cutters. Backloading thread shortened time taken to cut thread (p < 0.001) compared with free-hand cutting. Nd: YAG laser was ineffective in cutting uncolored threads and slower than mechanical cutters. Results of thread cutting in clinical studies using sewing machine (n = 77 cutting episodes in 21 patients), in-vivo experiments (n = 156), and postsurgical cases (n = 15 over 15 years) are presented. New thread-cutting methods are described and their efficacy demonstrated in experimental and clinical studies.
Recognition of surgical skills using hidden Markov models
NASA Astrophysics Data System (ADS)
Speidel, Stefanie; Zentek, Tom; Sudra, Gunther; Gehrig, Tobias; Müller-Stich, Beat Peter; Gutt, Carsten; Dillmann, Rüdiger
2009-02-01
Minimally invasive surgery is a highly complex medical discipline and can be regarded as a major breakthrough in surgical technique. A minimally invasive intervention requires enhanced motor skills to deal with difficulties like the complex hand-eye coordination and restricted mobility. To alleviate these constraints we propose to enhance the surgeon's capabilities by providing a context-aware assistance using augmented reality techniques. To recognize and analyze the current situation for context-aware assistance, we need intraoperative sensor data and a model of the intervention. Characteristics of a situation are the performed activity, the used instruments, the surgical objects and the anatomical structures. Important information about the surgical activity can be acquired by recognizing the surgical gesture performed. Surgical gestures in minimally invasive surgery like cutting, knot-tying or suturing are here referred to as surgical skills. We use the motion data from the endoscopic instruments to classify and analyze the performed skill and even use it for skill evaluation in a training scenario. The system uses Hidden Markov Models (HMM) to model and recognize a specific surgical skill like knot-tying or suturing with an average recognition rate of 92%.
Uemura, Munenori; Kenmotsu, Hajime; Tomikawa, Morimasa; Kumashiro, Ryuichi; Yamashita, Makoto; Ikeda, Testuo; Yamashita, Hiromasa; Chiba, Toshio; Hayashi, Koichi; Sakae, Eiji; Eguchi, Mitsuo; Fukuyo, Tsuneo; Chittmittrapap, Soottiporn; Navicharern, Patpong; Chotiwan, Pornarong; Pattana-Arum, Jirawat; Hashizume, Makoto
2015-05-01
Traditionally, laparoscopy has been based on 2-D imaging, which represents a considerable challenge. As a result, 3-D visualization technology has been proposed as a way to better facilitate laparoscopy. We compared the latest 3-D systems with high-end 2-D monitors to validate the usefulness of new systems for endoscopic diagnoses and treatment in Thailand. We compared the abilities of our high-definition 3-D endoscopy system with real-time compression communication system with a conventional high-definition (2-D) endoscopy system by asking health-care staff to complete tasks. Participants answered questionnaires and whether procedures were easier using our system or the 2-D endoscopy system. Participants were significantly faster at suture insertion with our system (34.44 ± 15.91 s) than with the 2-D system (52.56 ± 37.51 s) (P < 0.01). Most surgeons thought that the 3-D system was good in terms of contrast, brightness, perception of the anteroposterior position of the needle, needle grasping, inserting the needle as planned, and needle adjustment during laparoscopic surgery. Several surgeons highlighted the usefulness of exposing and clipping the bile duct and gallbladder artery, as well as dissection from the liver bed during laparoscopic surgery. In an image-transfer experiment with RePure-L®, participants at Rajavithi Hospital could obtain reconstructed 3-D images that were non-inferior to conventional images from Chulalongkorn University Hospital (10 km away). These data suggest that our newly developed system could be of considerable benefit to the health-care system in Thailand. Transmission of moving endoscopic images from a center of excellence to a rural hospital could help in the diagnosis and treatment of various diseases. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel
2010-05-01
Endoscopic full-thickness plication allows transmural suturing at the gastroesophageal junction to recreate the antireflux barrier. Multichannel intraluminal impedance monitoring (MII) can be used to detect nonacid or weakly acidic reflux, acidic swallows, and esophageal clearance time. This study used MII to evaluate the outcome of endoscopic full-thickness plication. In this study, 12 subsequent patients requiring maintenance proton pump inhibitor therapy underwent endoscopic full-thickness plication for treatment of gastroesophageal reflux disease. With patients off medication, MII was performed before and 6-months after endoscopic full-thickness plication. The total median number of reflux episodes was significantly reduced from 105 to 64 (p = 0.016). The median number of acid reflux episodes decreased from 73 to 43 (p = 0.016). Nonacid reflux episodes decreased from 23 to 21 (p = 0.306). The median bolus clearance time was 12 s before treatment and 11 s at 6 months (p = 0.798). The median acid exposure time was reduced from 6.8% to 3.4% (p = 0.008), and the DeMeester scores were reduced from 19 to 12 (p = 0.008). Endoscopic full-thickness plication significantly reduced total reflux episodes, acid reflux episodes, and total reflux exposure time. The DeMeester scores and total acid exposure time for the distal esophagus were significantly improved. No significant changes in nonacid reflux episodes and median bolus clearance time were encountered.
Endoscopic sleeve gastroplasty (the Apollo method): a new approach to obesity management.
López-Nava Breviere, Gontrand; Bautista-Castaño, Inmaculada; Fernández-Corbelle, Juan Pedro; Trell, Marta
2016-04-01
Many obese patients cannot lose weight or reject conventional obesity management. Endoscopic sleeve gastroplasty (the Apollo method) is a pioneering coadjuvant, interventionist technique for the integral management of obesity. The goals of this study were to report safety and efficacy results obtained at 6 months in patients undergoing endoscopic sleeve gastroplasty. A prospective study was performed in 55 patients (13 males, 42 females) who were subjected to the Apollo technique; mean age was 43.5 years (range 25-60) and mean BMI was 37.7 kg/m2 (range 30-48). All received multidisciplinary follow-up for weight loss. Weight changes and presence of complications were assessed. Through the endoscope a triangular pattern suture is performed consisting of approximately 3-6 transmural (mucosa to serosa) stitches, using a cinch device to bring them nearer and form a plication. A total of 6-8 plications are used to provide a tubular or sleeve-shaped restriction to the gastric cavity. No major complications developed and patients were discharged at 24 hours following the procedure. Endoscopic and radiographic follow-up at 6 months post-procedure showed a well preserved tubular form to the stomach. After 6 months patients had lost 18.9 kg and 55.3% of excess weight. Endoscopic sleeve gastroplasty, together with dietary and psycho-behavioral changes, is a safe, effective technique in the coadjuvant management of obese patients.
Mucosal excision and suturing for obesity and GERD.
Légner, András; Tsuboi, Kazuto; Stadlhuber, Rudolf; Yano, Fumiaki; Halvax, Peter; Hunt, Brandon; Penka, Wayne; Filipi, Charles J
2013-12-01
Suture and staple-based endoluminal devices for gastroesophageal reflux disease (GERD) and obesity have failed to demonstrate long-term efficacy. To demonstrate the feasibility of mucosal excision and full-thickness suture apposition of the excision beds to create sufficient scar tissue formation at the gastroesophageal junction for the intraluminal treatment of GERD or obesity. Survival animal experiments. Seven mongrel dogs. Interventions. Under general endotracheal anesthesia, a Barostat test was performed on 4 dogs. A mucosal excision device was introduced through the esophagus into the proximal stomach. Two to 4 mucosal excisions were performed on all dogs at or just below the gastroesophageal junction and the mucosal pieces were removed. After hemostasis, an intraluminal suturing instrument was introduced and either 2 or 4 sutures were placed through the excision beds to bring them into apposition. These were tied and the suture strands cut. All dogs were survived for 2 months. End-term endoscopies were performed, and a repeat Barostat procedure was performed on the animals undergoing an antireflux procedure. After euthanasia the stomachs were explanted, examined, photographed, and sectioned for histologic examination. All dogs survived without complication. In the 4 GERD dogs, the Barostat studies demonstrated a significant decrease in gastroesophageal junction compliance. In the 3 dogs undergoing the obesity procedure, the gastric outlet apposition to a 6-mm endoscope was satisfactory with full insufflation and the desired scarring was seen on histologic examination. It is possible to create adequate gastroesophageal junction scarring for the treatment of GERD and obesity. A clinical pilot study will be initiated.
[A new method of endoscopic harvesting of the great saphenous vein in an open system].
Vecherskiĭ, Iu Iu; Zatolokin, V V; Petlin, K A; Akhmedov, Sh D; Shipulin, V M
We examined a total of 246 patients subjected to coronary artery bypass grafting with the use of the great saphenous vein (GSV). The patients were subdivided into two groups. Group One (n=121) patients endured procurement of the great saphenous vein by a new endoscopic technique in an open system with the help of the equipment Karl Storz and electric dissector Ligasure. In Group Two (n=125) patients the vein was harvested by means of the traditional open method. In all patients we evaluated complications in the early postoperative period 13±2.5 days after the operation. The rate of relapsing angina pectoris in both Groups turned out to be low and did not differ (1.65% in Group One and 1.6% in Group Two). Patients of the both groups differed significantly by the incidence of postoperative complications on the lower limbs in the zone of procurement of the GSV (9.09% in Group One and 26.4% in Group Two, p=0.131). Group Two patients (open method of procurement of the GSV) were considerably more often found to have developed cases of lymphorrhoea, haematomas, disjunction of the sutures (21.6%) compared with Group One (endoscopic method) patients (3.3%) (p=0.167), which in 10.4% of cases required secondary surgical debridement of wounds in patients after the open harvest of the GSV. Eventually, the length of hospital stay for Group Two patients increased significantly (15 ± 4.5 days) compared with Group One patients (8±1.1 days) (p=0.361). Hence, the endoscopic method of harvesting the GSV in the open CO2 system makes it possible to obtain a good cosmetic effect on the lower limbs after the operation, to considerably decrease the complications rate, thus reducing the length of hospital stay.
[Ultrasonic monitoring foam sclerotherapy for serious varicosis of lower extremity].
Yin, Heng-hui; Pan, Fu-shun; Huang, Xue-ling; Chang, Guang-qi; Wang, Shen-ming
2013-11-19
To evaluate the efficacy and safety of foam sclerotherapy for lower extremity varicosis in C4 to C6 patients. A total of 32 patients (32 limbs) with serious lower extremity varicosis classified as C4 to C6 were enrolled. Ultrasonic monitoring of foam sclerotherapy was performed after subfascial endoscopic perforator suture and saphenous vein ligation. They were followed up monthly at outpatient department. Duplex Doppler scan was performed during each interview. All patients were treated successfully. An average of 3.2 perforators were ligated per leg (1-5 perforators). The average volume of foam sclerosing agent was 27.5 ml per leg. Mild chest tightness was observed in one patient but computed tomography (CT) scan excluded pulmonary embolism. Obvious local inflammatory reaction was observed in 4 patients. Residual vein mass without blood signal was seen in 3 patients. No such serious complication as cerebral ischemia was observed. The average follow-up period was 4.8 (1-10) months. Obvious varicose veins and clinical symptoms disappeared at 1 month. And venous ulcers in patients classified as C5 healed within 3 months. Ultrasonic monitoring of foam sclerotherapy, incorporation with saphenous vein ligation and subfascial endoscopic perforator suture, is both safe and effective in the treatment of serious lower extremity varicosis classified as C4 to C6.
Sripathi, V; Mitra, Aparajita; Padankatti, Rajiv L; Ganesan, T
2017-10-27
Calyceal diverticula in children are rare and 20% eventually become symptomatic. Following the use of laparoscopic or endoscopic treatments, 85% of children report symptomatic relief. However, complete radiological resolution is seen only in three-fourths of the laparoscopic group and a quarter of those treated via endoscopy. Diathermy ablation of the lining and/or prolonged double J stenting has not altered this outcome. The robotic approach is superior to the other two techniques as the leak can be clearly identified and securely suture ligated. We believe that this is the third published report of the successful closure of a calyceal diverticulum in a child using robotic assistance. A ten-year-old boy presented with severe pain in the right flank and a palpable renal swelling. Retrograde injection of contrast outlined a large exophytic calyceal diverticulum (type 2) in the lower pole. Robotic assistance allowed precise suture closure of the neck as well as partial marsupialisation of the diverticulum. The child was discharged within 48 h and remains symptom free 18 months later. Calyceal diverticula are rare but technically challenging entities. We have shown a good outcome with only suture closure of the leak. Diathermy ablation of the lining and prolonged internal stenting were avoided.
Taghizadeh, Farhan; Reiley, Carol; Mohr, Catherine; Paul, Malcolm
2014-03-01
We are evaluating the technical feasibility of robotic-assisted laparoscopic vertical-intermediate platysmaplasty in conjunction with an open rhytidectomy. In a cadaveric study, the da Vinci Surgical System was used to access certain angles in the lower neck that are difficult for traditional short incision, short flap procedures. Ergonomics, approach, and technical challenges were noted. To date, there are no published reports of robotic-assisted neck lifts, motivating us to assess its potential in this field of plastic surgery. Standard open technique short flap rhytidectomies with concurrent experimental robotic-assisted platysmaplasties (neck lifts) were performed on six cadavers with the da Vinci Si Surgical System(®) (Intuitive Surgical, Sunnyvale, CA, USA). The surgical procedures were performed on a diverse cadaver population from June 2011 to January 2012. The procedures included (1) submental incision and laser-assisted liposuction, (2) open rhytidectomy, and (3) robotic-assisted platysmaplasty using knot-free sutures. A variety of sutures and fat extraction techniques, coupled with 0° and 30° three-dimensional endoscopes, were utilized to optimize visualization of the platysma. An unaltered da Vinci Si Surgical System with currently available instruments was easily adaptable to neck lift surgery. Mid-neck platysma exposure was excellent, tissue handling was delicate and precise, and suturing was easily performed. Robotic-assisted surgery has the potential to improve outcomes in neck lifts by offering the ability to manipulate instruments with increased freedom of movement, scaled motion, tremor reduction, and stereoscopic three-dimensional visualization in the deep neck. Future clinical studies on live human patients can better assess subject and surgeon benefits arising from the use of the da Vinci system for neck lifts. Evidence obtained from multiple time series with or without the intervention, such as case studies. Dramatic results in uncontrolled trials might also be regarded as this type of evidence.
Submucosal tunnel endoscopy: Peroral endoscopic myotomy and peroral endoscopic tumor resection
Eleftheriadis, Nikolas; Inoue, Haruhiro; Ikeda, Haruo; Onimaru, Manabu; Maselli, Roberta; Santi, Grace
2016-01-01
Peroral endoscopic myotomy (POEM) is an innovative, minimally invasive, endoscopic treatment for esophageal achalasia and other esophageal motility disorders, emerged from the natural orifice transluminal endoscopic surgery procedures, and since the first human case performed by Inoue in 2008, showed exciting results in international level, with more than 4000 cases globally up to now. POEM showed superior characteristics than the standard 100-year-old surgical or laparoscopic Heller myotomy (LHM), not only for all types of esophageal achalasia [classical (I), vigorous (II), spastic (III), Chicago Classification], but also for advanced sigmoid type achalasia (S1 and S2), failed LHM, or other esophageal motility disorders (diffuse esophageal spasm, nutcracker esophagus or Jackhammer esophagus). POEM starts with a mucosal incision, followed by submucosal tunnel creation crossing the esophagogastric junction (EGJ) and myotomy. Finally the mucosal entry is closed with endoscopic clip placement. POEM permitted relatively free choice of myotomy length and localization. Although it is technically demanding procedure, POEM can be performed safely and achieves very good control of dysphagia and chest pain. Gastroesophageal reflux is the most common troublesome side effect, and is well controllable with proton pump inhibitors. Furthermore, POEM opened the era of submucosal tunnel endoscopy, with many other applications. Based on the same principles with POEM, in combination with new technological developments, such as endoscopic suturing, peroral endoscopic tumor resection (POET), is safely and effectively applied for challenging submucosal esophageal, EGJ and gastric cardia tumors (submucosal tumors), emerged from muscularis propria. POET showed up to know promising results, however, it is restricted to specialized centers. The present article reviews the recent data of POEM and POET and discussed controversial issues that need further study and future perspectives. PMID:26839649
Schaarschmidt, Klaus; Lempe-Sellin, Michael; Schlesinger, Frank; Jaeschke, Uwe; Polleichtner, Susanne
2011-04-01
Since 2001 we minimized access (2.9-4.7 cm) for universally applicable endoscopic hybrid carinatum technique with two transsternal Willital bars in 173 endoscopic hybrid (EH) patients with very satisfactory results. In 2008-2009, endoscopic Nuss bar compression with endoscopic repair of costal flaring applied a new eight-hole stabilizer, which allows the use in pectus carinatum (PC) beyond adolescence including redos and combined deformities. This prospective study of 35 "endoscopic Berlin-Buch reversed Nuss" repairs intends to establish indications for this improved technique. In February 2008 to February 2010, we used endoscopic Nuss bar compression by applying a bilateral new eight-hole stabilizer fixed to the bar without screws or wires, which allows unprecedented versatility and the use in pectus carinatum beyond adolescence. Thirty-five patients aged 17.05 ± 10.2 years (range: 11.3-33.1 years) were recorded prospectively and followed at 3 monthly intervals. We implanted a standard Nuss bar (11-14') into an endoscopically dissected submuscular presternal pocket correcting PC by sternal pressure. The bars were put under tension by traction via bilateral eight-hole stabilizers and three pericostal wire sutures on each side. Bars were removed after 2 years. All 35 "reversed Nuss" pectus carinatum repairs, including 2 redos after Ravitch, were successful, with no conversion. So far there was no local or general complication and no seroma or bar dislocation. Thirty-one patients judged their result as excellent and 4 as good. Although this is a very early experience, "reversed Nuss" is safe and effective and new technical improvements have expanded the range of applicability to older patients and suitable redos.
Althaus, C; Sundmacher, R
1993-08-01
Two technical difficulties have to be overcome in transscleral suture fixation of posterior chamber intraocular lenses (PCL) in the ciliary sulcus: first, exact needle penetration through the sulcus, and second, exact positioning of the PCL haptics in the sulcus. Incongruence of the two may lead to long-term complications by compression or even strangulation of ciliary processes. Intraocular endoscopy was used intraoperatively to visualize the site of needle penetration and the final location of the haptics in patients. It turned out that with our previously described standard techniques the precision was far less than anticipated. Thus, new technical ways had to be sought to improve the precision of positioning. In secondary implantation without perforating keratoplasty we achieved the best results when the needle was passed ab externo before opening the eye and before anterior vitrectomy, taking advantage of a precisely prepared sclerocorneal zone. Passing the needle ab externo in an already hypotonic eyeball gives much less precise results. In combination with perforating keratoplasty with an open-sky approach, needle penetration ab interno is reliable. Correct positioning of the PCL haptics is at least as difficult as correct needle penetration, a fact which up to now has mostly been ignored. In 33 consecutively operated eyes the technique of implantation and PCL design was varied under endoscopical control.(ABSTRACT TRUNCATED AT 250 WORDS)
Tanjararak, Kangsadarn; Upadhyay, Smita; Thiensri, Thanakorn; Muto, Jun; Roongpuvapaht, Boonsam; Prevedello, Daniel M; Carrau, Ricardo L
2018-06-01
Objectives Endoscopic and endoscopic-assisted approaches to the parapharyngeal space have been reported; however, their potential for vascular exposure has not been previously assessed. This study aims to compare the potential exposure and control of the parapharyngeal internal carotid artery (ppICA) via various approaches. Design and Main Outcome Measures Ten cadaveric specimens were dissected bilaterally, exposing the ppICA via endonasal, transoral, and transcervical approaches. Length of the exposed vessel and potential control were assessed (feasibility and time required to place an encircling suture). Results Endoscopic transoral and transcervical-transmandibular approaches expose a significantly longer segment of the ppICA (6.89 and 7.09 cm) than the transoral and endonasal approaches. Vascular control was achieved via endoscopic-endonasal, endoscopic-transoral, and open techniques in 121.6, 64.8, and 5.2 seconds, respectively. Conclusion Histopathology, goals of surgery, and familiarity of the surgeon with each technique may ultimately determine the choice of approach; however, this study suggests that exposure of the ppICA by endoscopic-assisted transoral approach is comparable to that of a transcervical-transmandibular approach. Vascular control was feasible under elective circumstances. However, the difficulty varied widely, potentially reflecting the challenges of controlling an injured ppICA. However, one must note that active bleeding obscures the surgical field in ways that may impair ppICA control. Furthermore, the results may not reflect clinical scenarios where tumor distorts the surgical field. Nonetheless, the study suggests that, in properly selected patients, the endoscopic-assisted transoral approach avoids problems associated with unsightly scars, mandibular osteotomy, and facial nerve manipulation, whereas, the transcervical-transmandibular approach offers the swiftest vascular control.
Local resection of the stomach for gastric cancer.
Kinami, Shinichi; Funaki, Hiroshi; Fujita, Hideto; Nakano, Yasuharu; Ueda, Nobuhiko; Kosaka, Takeo
2017-06-01
The local resection of the stomach is an ideal method for preventing postoperative symptoms. There are various procedures for performing local resection, such as the laparoscopic lesion lifting method, non-touch lesion lifting method, endoscopic full-thickness resection, and laparoscopic endoscopic cooperative surgery. After the invention and widespread use of endoscopic submucosal dissection, local resection has become outdated as a curative surgical technique for gastric cancer. Nevertheless, local resection of the stomach in the treatment of gastric cancer in now expected to make a comeback with the clinical use of sentinel node navigation surgery. However, there are many issues associated with local resection for gastric cancer, other than the normal indications. These include gastric deformation, functional impairment, ensuring a safe surgical margin, the possibility of inducing peritoneal dissemination, and the associated increase in the risk of metachronous gastric cancer. In view of these issues, there is a tendency to regard local resection as an investigative treatment, to be applied only in carefully selected cases. The ideal model for local resection of the stomach for gastric cancer would be a combination of endoscopic full-thickness resection of the stomach using an ESD device and hand sutured closure using a laparoscope or a surgical robot, for achieving both oncological safety and preserved functions.
Automatically rating trainee skill at a pediatric laparoscopic suturing task.
Oquendo, Yousi A; Riddle, Elijah W; Hiller, Dennis; Blinman, Thane A; Kuchenbecker, Katherine J
2018-04-01
Minimally invasive surgeons must acquire complex technical skills while minimizing patient risk, a challenge that is magnified in pediatric surgery. Trainees need realistic practice with frequent detailed feedback, but human grading is tedious and subjective. We aim to validate a novel motion-tracking system and algorithms that automatically evaluate trainee performance of a pediatric laparoscopic suturing task. Subjects (n = 32) ranging from medical students to fellows performed two trials of intracorporeal suturing in a custom pediatric laparoscopic box trainer after watching a video of ideal performance. The motions of the tools and endoscope were recorded over time using a magnetic sensing system, and both tool grip angles were recorded using handle-mounted flex sensors. An expert rated the 63 trial videos on five domains from the Objective Structured Assessment of Technical Skill (OSATS), yielding summed scores from 5 to 20. Motion data from each trial were processed to calculate 280 features. We used regularized least squares regression to identify the most predictive features from different subsets of the motion data and then built six regression tree models that predict summed OSATS score. Model accuracy was evaluated via leave-one-subject-out cross-validation. The model that used all sensor data streams performed best, achieving 71% accuracy at predicting summed scores within 2 points, 89% accuracy within 4, and a correlation of 0.85 with human ratings. 59% of the rounded average OSATS score predictions were perfect, and 100% were within 1 point. This model employed 87 features, including none based on completion time, 77 from tool tip motion, 3 from tool tip visibility, and 7 from grip angle. Our novel hardware and software automatically rated previously unseen trials with summed OSATS scores that closely match human expert ratings. Such a system facilitates more feedback-intensive surgical training and may yield insights into the fundamental components of surgical skill.
[The use of staplers for intestinal anastomosis in newborns].
Kozlov, Iu A; Novozhilov, V A; Podkamenev, A V; Veber, I N
2013-01-01
The comparative experience of mechanical and manual intestinal anastomoses in newborns was analyzed. The main group (mechanical suture) consisted of 23 patients; the group of control consisted of 21 little patients. The mechanical intestinal suture was performed with the use of linear endoscopic stapler with 2.5 mm high staples. There were no differences in age and body weight between the two groups. The mean operative time was 77.4 min for the 1st group, whereas for the 2nd group it was 56.4 min. There were no significant difference in time before enteral feeding after the operation - 6.7 days on average. The hospital stay time was also identical (13.3 vs. 14.1 days). Postoperative period was uncomplicated in both groups. Thus, the use of mechanical stapler for intestinal anastomosis allows shorten the operative time, though preserving the same results of hospital stay and enteral feeding beginning.
Arain, Nabeel A; Cadeddu, Jeffrey A; Best, Sara L; Roshek, Thomas; Chang, Victoria; Hogg, Deborah C; Bergs, Richard; Fernandez, Raul; Webb, Erin M; Scott, Daniel J
2012-04-01
This study aimed to evaluate the surgeon performance and workload of a next-generation magnetically anchored camera compared with laparoscopic and flexible endoscopic imaging systems for laparoscopic and single-site laparoscopy (SSL) settings. The cameras included a 5-mm 30° laparoscope (LAP), a magnetically anchored (MAGS) camera, and a flexible endoscope (ENDO). The three camera systems were evaluated using standardized optical characteristic tests. Each system was used in random order for visualization during performance of a standardized suturing task by four surgeons. Each participant performed three to five consecutive repetitions as a surgeon and also served as a camera driver for other surgeons. Ex vivo testing was conducted in a laparoscopic multiport and SSL layout using a box trainer. In vivo testing was performed only in the multiport configuration and used a previously validated live porcine Nissen model. Optical testing showed superior resolution for MAGS at 5 and 10 cm compared with LAP or ENDO. The field of view ranged from 39 to 99°. The depth of focus was almost three times greater for MAGS (6-270 mm) than for LAP (2-88 mm) or ENDO (1-93 mm). Both ex vivo and in vivo multiport combined surgeon performance was significantly better for LAP than for ENDO, but no significant differences were detected for MAGS. For multiport testing, workload ratings were significantly less ex vivo for LAP and MAGS than for ENDO and less in vivo for LAP than for MAGS or ENDO. For ex vivo SSL, no significant performance differences were detected, but camera drivers rated the workload significantly less for MAGS than for LAP or ENDO. The data suggest that the improved imaging element of the next-generation MAGS camera has optical and performance characteristics that meet or exceed those of the LAP or ENDO systems and that the MAGS camera may be especially useful for SSL. Further refinements of the MAGS camera are encouraged.
Ojima, Toshiyasu; Nakamori, Mikihito; Nakamura, Masaki; Hayata, Keiji; Maruoka, Shimpei; Yamaue, Hiroki
2018-04-20
Compared with total gastrectomy, proximal gastrectomy (PG) has potential advantages from a nutritional perspective, such as anemia and postoperative loss of body weight. However, PG is associated with some postoperative functional disorders, such as reflux esophagus (13-31%) and anastomotic stenosis (3-29%).1 We therefore developed a new procedure for fundoplication during esophago-gastrostomy after robotic PG (RPG). We performed RPG for early gastric cancer localized in the upper third of the stomach using the da Vinci Surgical System (Intuitive, Sunnyvale, CA). After RPG conclusion, intracorporeal esophago-gastrostomy was performed by side-to-side anastomosis using a linear 45 mm stapling device, Endo GIA purple cartridge.2 The post-excisional hole in the esophago-gastrostomy was closed with interrupted single-layered sutures by robotic suturing technique. Fundoplication was created by wrapping the remnant stomach around 180 degrees of the circumference of the esophagus; the remnant stomach was wrapped from the esophageal posterior wall towards the esophageal anterior wall. Four stitches were used for fixation. We did not add a bougie of esophago-gastrostomy when fashioning the wrap. In addition, we did not perform pyloroplasty. In our series with 15 patients, there were no postoperative complications. No patients had reflux symptoms. Our technique using the fundoplication with "clockwise" rotation attempts to prevent reflux by use of intragastric pressure to flatten the lower end of the esophagus into a valvate shape. Indeed, in fluoroscopic findings 4 days after surgery, there was no reflux to the esophagus of the contrast medium. In endoscopic findings 3 months after surgery, anastomotic stenosis was absent. We observed no endoscopic findings of reflux esophagitis. Formation of the pseudo-fornix was confirmed by wrapping the remnant stomach. RPG followed by fundoplication with 180-degree wrap may be a promising procedure for reflux esophagitis prevention.3,4 However, long-term follow-up is required to show benefits of this new procedure.4.
Newly designed "pieced" stent in a rabbit model of benign esophageal stricture.
Liu, Jin; Shang, Liang; Liu, Ji-Yong; Qin, Cheng-Yong
2015-07-28
To investigate a newly designed stent and its dilatation effect in a rabbit model of benign esophageal stricture. Thirty-four New Zealand white rabbits underwent a corrosive injury in the middle esophagus for esophageal stricture formation. Thirty rabbits with a successful formation of esophageal strictures were randomly allocated into two groups. The control group (n = 15) was implanted with a conventional stent, and the study group (n = 15) was implanted with a detachable "pieced" stent. The study stent (30 mm in length, 10 mm in diameter) was composed of three covered metallic pieces connected by surgical suture lines. The stent was collapsed by pulling the suture lines out of the mesh. Two weeks after stricture formation, endoscopic placement of a conventional stent or the new stent was performed. Endoscopic extraction was carried out four weeks later. The extraction rate, ease of extraction, migration, complications, and survival were evaluated. Stent migration occurred in 3/15 (20%) animals in the control group and 2/15 (13%) animals in the study group; the difference between the two groups was not statistically significant. At the end of four weeks, the remaining stents were successfully extracted with the endoscope in 100% (11/11) of the animals in the study group, and 60% (6/10) of the animals in the control group; this difference was statistically significant (P < 0.05). There was no difference in the mean number of follow-up days between the control and study groups (25.33 vs 25.85). Minor bleeding was reported in five cases in the study group and four in the control group. There were no severe complications directly associated with stent implantation or extraction in either of the two groups. In this experimental protocol of benign esophageal strictures, the novel "pieced" stent demonstrated a superior removal rate with a similar migration rate compared to a conventional stent.
Laparoscopic and endoscopic co-operative surgery for non-ampullary duodenal tumors
Ichikawa, Daisuke; Komatsu, Shuhei; Dohi, Osamu; Naito, Yuji; Kosuga, Toshiyuki; Kamada, Kazuhiro; Okamoto, Kazuma; Itoh, Yoshito; Otsuji, Eigo
2016-01-01
AIM To assess the safety and feasibility of laparoscopic and endoscopic co-operative surgery (LECS) for early non-ampullary duodenal tumors. METHODS Twelve patients with a non-ampullary duodenal tumor underwent LECS at our hospital. One patient had two mucosal lesions in the duodenum. The indication for this procedure was the presence of duodenal tumors with a low risk for lymph node metastasis. In particular, the tumors included small (less than 10 mm) submucosal tumors (SMT) and epithelial mucosal tumors, such as mucosal cancers or large mucosal adenomas with malignant suspicion. The LECS procedures, such as full-thickness dissection for SMT and laparoscopic reinforcement after endoscopic submucosal dissection (ESD) for epithelial tumors, were performed for the 13 early duodenal lesions in 12 patients. Here we present the short-term outcomes and evaluate the safety and feasibility of this new technique. RESULTS Two SMT-like lesions and eleven superficial epithelial tumor-like lesions were observed. Seven and Six lesions were located in the second and third parts of the duodenum, respectively. All lesions were successfully resected en bloc. The defect in the duodenal wall was manually sutured after resection of the duodenal SMT. For epithelial duodenal tumors, the ulcer bed was laparoscopically reinforced via manual suturing after ESD. Intraoperative perforation occurred in two out of eleven epithelial tumor-like lesions during ESD; however, they were successfully laparoscopically repaired. The median operative time and intraoperative estimated blood loss were 322 min and 0 mL, respectively. Histological examination of the tumors revealed one adenoma with moderate atypia, ten adenocarcinomas, and two neuroendocrine tumors. No severe postoperative complications (Clavien-Dindo classification grade III or higher) were reported in this series, but minor leakage secondary to pancreatic fistula occurred in one patient. CONCLUSION LECS can be a safe and minimally invasive treatment option for non-ampullary early duodenal tumors. PMID:28058023
Laparoscopic and endoscopic co-operative surgery for non-ampullary duodenal tumors.
Ichikawa, Daisuke; Komatsu, Shuhei; Dohi, Osamu; Naito, Yuji; Kosuga, Toshiyuki; Kamada, Kazuhiro; Okamoto, Kazuma; Itoh, Yoshito; Otsuji, Eigo
2016-12-21
To assess the safety and feasibility of laparoscopic and endoscopic co-operative surgery (LECS) for early non-ampullary duodenal tumors. Twelve patients with a non-ampullary duodenal tumor underwent LECS at our hospital. One patient had two mucosal lesions in the duodenum. The indication for this procedure was the presence of duodenal tumors with a low risk for lymph node metastasis. In particular, the tumors included small (less than 10 mm) submucosal tumors (SMT) and epithelial mucosal tumors, such as mucosal cancers or large mucosal adenomas with malignant suspicion. The LECS procedures, such as full-thickness dissection for SMT and laparoscopic reinforcement after endoscopic submucosal dissection (ESD) for epithelial tumors, were performed for the 13 early duodenal lesions in 12 patients. Here we present the short-term outcomes and evaluate the safety and feasibility of this new technique. Two SMT-like lesions and eleven superficial epithelial tumor-like lesions were observed. Seven and Six lesions were located in the second and third parts of the duodenum, respectively. All lesions were successfully resected en bloc . The defect in the duodenal wall was manually sutured after resection of the duodenal SMT. For epithelial duodenal tumors, the ulcer bed was laparoscopically reinforced via manual suturing after ESD. Intraoperative perforation occurred in two out of eleven epithelial tumor-like lesions during ESD; however, they were successfully laparoscopically repaired. The median operative time and intraoperative estimated blood loss were 322 min and 0 mL, respectively. Histological examination of the tumors revealed one adenoma with moderate atypia, ten adenocarcinomas, and two neuroendocrine tumors. No severe postoperative complications (Clavien-Dindo classification grade III or higher) were reported in this series, but minor leakage secondary to pancreatic fistula occurred in one patient. LECS can be a safe and minimally invasive treatment option for non-ampullary early duodenal tumors.
Pelvic fracture urethral injuries: the unresolved controversy.
Koraitim, M M
1999-05-01
The unresolved controversies about pelvic fracture urethral injuries and whether any conclusions can be reached to develop a treatment plan for this lesion are determined. All data on pelvic fracture urethral injuries in the English literature for the last 50 years were critically analyzed. Studies were eligible only if data were complete and conclusive. The risk of urethral injury is influenced by the number of broken pubic rami as well as involvement of the sacroiliac joint. Depending on the magnitude of trauma, the membranous urethra is first stretched and then partially or completely ruptured at the bulbomembranous junction. Injuries to the prostatic urethra and bladder neck occur only in children. Injury to the female urethra usually is a partial tear of the anterior wall and rarely complete disruption of the proximal or distal urethra. Diagnosis depends on urethrography in men and on a high index of suspicion and urethroscopy in women. Of the 3 conventional treatment methods primary suturing of the disrupted urethral ends has the greatest complication rates of incontinence and impotence (21 and 56%, respectively). Primary realignment has double the incidence of impotence and half that of stricture compared to suprapubic cystostomy and delayed repair (36 versus 19 and 53 versus 97%, respectively, p <0.0001). In men surgical and endoscopic procedures do not compete but rather complement each other for treatment of different injuries under different circumstances, including indwelling catheter for urethral stretch injury, endoscopic stenting or suprapubic cystostomy for partial rupture, endoscopic realignment or suprapubic cystostomy for complete rupture with a minimal distraction defect and surgical realignment if the distraction defect is wide. Associated injury to the bladder, bladder neck or rectum dictates immediate exploration for repair but does not necessarily indicate exploration of the urethral injury site. In women treatment modalities are dictated by the level of urethral injury, including immediate retropubic realignment or suturing for proximal and transvaginal urethral advancement for distal injury.
Treatment of subtotal medial rectus myectomy complicating functional endoscopic sinus surgery.
Trotter, W L; Kaw, P; Meyer, D R; Simon, J W
2000-08-01
During the past 2 decades, the introduction of functional endoscopic sinus surgery (FESS) has dramatically improved the treatment of sinus disorders. However, a variety of orbital complications have been reported, including optic nerve damage, hemorrhage, infection, compromise of the lacrimal drainage apparatus, and strabismus. At least 10 cases have reported damage to the medial rectus muscle. (1-8) Treatment options for such patients have been limited, especially because most are adults at risk for anterior segment ischemia after transposition of vertical rectus muscles. We describe 2 patients whose medial rectus myectomies were repaired by using nonabsorbable "hang-back" sutures in combination with a botulinum toxin (Botox) injection of the antagonist lateral rectus muscle. Good primary position alignment was achieved in both patients, and one patient was able to regain binocular function. We recommend this surgical approach, especially in patients at increased risk for anterior segment ischemia.
Hiraki, Masatsugu; Ueda, Junji; Kono, Hiroshi; Egawa, Noriyuki; Saeki, Kiyoshi; Tsuru, Yasuhiro; Ide, Takao; Noshiro, Hirokazu
2017-11-01
The use of laparoscopic surgery in the treatment of Mirizzi syndrome is considered controversial due to the degree of technical difficulty. We herein describe the case of a 36-year-old woman who was admitted to our hospital due to appetite loss, nausea and back pain. Endoscopic retrograde cholangiography revealed a round-shaped filling defect at the confluence of the bile duct. The patient was diagnosed with Mirizzi syndrome Type II according to the Csendes classification. Before surgery, an endoscopic nasobiliary drainage tube was placed for intraoperative cholangiography. Based on the intraoperative findings, the anterior wall of Hartmann's pouch was excised to remove the impacted gallstone. The neck portion of the gallbladder wall was then used to make a gallbladder patch, which was sutured to cover the anterior wall of the common hepatic bile duct. Laparoscopic choledochoplasty using a gallbladder patch was a technically feasible treatment for Mirizzi syndrome Type II.
21 CFR 870.3460 - Endovascular Suturing System.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...
21 CFR 870.3460 - Endovascular Suturing System.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...
21 CFR 870.3460 - Endovascular Suturing System.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...
Mantzoukis, Konstantinos; Papadimitriou, Kassiani; Kouvelis, Ioannis; Theocharidou, Athina; Zebekakis, Pantelis; Vital, Victor; Nikolaidis, Pavlos; Germanidis, Georgios
2011-01-01
We present a case report regarding a 74-year-old male with iatrogenic esophageal perforation, after an attempt to remove a food bolus impaction at Lannier’s triangle (proximal esophagus). The perforation was treated endoscopically (flexible EGD) by clip application in two sessions, with excellent outcome. Esophageal perforations occur rarely, usually following a medical procedure. The clinical manifestations are often insidious with potentially catastrophic complications. Although the majority of cases have been treated conservatively and/or operatively over the years, there is a rising tendency for non-operative endoscopic interventions due to the high morbidity and mortality rates seen even in specialized units. For this reason self-expandable stents, endoclips, tissue sealants and suturing devices have been used. A high degree of clinical suspicion is essential for successful management of esophageal perforations, as is early decision to intervene and respect for basic surgical principles such as prevention and limitation of extraesophageal contamination, prevention of reflux of gastric contents and restoration of gastrointestinal tract integrity. The published reports on the use of endoclips for repairing perforations of the proximal esophagus are rare. To our knowledge, this is the first case report regarding the endoscopic application of endoclips for the successful closure of an iatrogenic perforation at Lannier’s triangle. PMID:24714287
Esophageal incisions repair by CO2 laser soldering.
Nageris, Ben I; Zilker, Zeev; Zilker, Maya; Kariv, Noam; Feinmesser, Rafael; Katzir, Abraham
2004-12-01
This study evaluated the feasibility of fiberoptic CO2 laser soldering for the repair of esophageal injuries under tight temperature feedback control in an animal model. Healing was compared to conventional suture closure. A CO2 soldering system equipped with infrared transmitting silver halide fibers was used. The soldered tissue temperature was monitored continuously, and laser power was adjusted to provide constant temperature. The procedure was done with 50% bovine serum albumin solder. Longitudinal incisions measuring 8 to 10 mm were made under general anesthesia in the cervical esophagus of 25 rats. Twenty rats (group I) underwent laser tissue bonding; 8 of which were tested in a preliminary study to determine optimal laser parameters. In the remaining 5 rats (group II, controls), closure was performed with 1 layer of 6/0 Vicryl sutures. The rats were sacrificed 2, 3, 4, and 6 weeks postoperatively, and the esophagus was examined histologically. Optimal temperature was found to be 65 to 70 degrees C and optimal exposure time, 150 to 200 seconds. Laser soldering was successful in 9 of the 12 rats (75%) treated under optimal settings; suturing was successful in 4 of the 5 control rats (80%). There were no significant differences between the groups in healing or complication rates. These results indicate that the CO2 laser soldering technique is a valid option for the correction of esophageal tears or incisions in rats. The confirmation and extension of these findings in further studies with larger animals may ultimately lead to the routine in vivo use of temperature-controlled laser repair for the esophagus and other organs. This method lends itself to endoscopic bonding of tissues.
Kim, Ki-Han; Kim, Min-Chan; Jung, Ghap-Joong; Jang, Jin-Seok; Choi, Seok-Ryeol
2012-01-01
Anastomotic leakage, bleeding, and stricture are major complications after gastrectomy. Of these complications, postoperative anastomotic bleeding is relatively rare, but lethal if not treated immediately. Of 2031 patients with gastric cancer who underwent radical gastrectomy (R0 resection) between January 2002 and December 2010, postoperative anastomotic bleeding was observed in 7 patients. The clinicopathological features, postoperative outcomes such as surgical procedures, bleeding sites and, methods used to achieve hemostasis, and the risk factors of anastomotic bleeding of these 7 patients were analyzed. Of the 2031 patients, 1613 and 418 underwent distal and total gastrectomy, respectively. The bleeding sites were as follows: Billroth-I anastomosis using a circular stapler (n = 1), Billroth-II anastomosis by manual suture (n = 5), and esophagojejunostomy using a circular stapler (n = 1). All patients were treated with endoscopic clipping or epinephrine injection. There was no further endoscopic intervention or reoperation for anastomotic bleeding. Postoperative anastomotic bleeding is an infrequent but potentially life-threatening complication. Scrupulous surgical procedures are essential for the prevention of postoperative bleeding, and endoscopy was useful for both the confirmation of bleeding and therapeutic intervention. Copyright © 2012 Surgical Associates Ltd. All rights reserved.
Glottic airway gain after 'suture arytenoid laterofixation' in bilateral vocal cord paralysis.
Korkmaz, Mehmet Hakan; Bayır, Ömer; Tatar, Emel Çadallı; Saylam, Güleser; Öcal, Bülent; Keseroğlu, Kemal; Özdek, Ali
2015-09-01
This method is an easy, non-expensive, and effective technique in bilateral vocal cord paralysis to improve glottic airway and clinical performance. To evaluate the effectiveness of 'suture arytenoid laterofixation' surgery in bilateral vocal cord paralysis. A retrospective analysis of patients' medical history undergoing 'suture arytenoid laterofixation' surgery for bilateral vocal cord paralysis. This technique was applied under general anesthesia with both microlaryngoscopy and video-monitoring. Two 16 g needles and one 1/0 nylon thread were used for the procedure with 1 cm skin incision; no tracheotomy or tissue excision was required. Pre-post-operative photographs of the glottic region were taken from the endoscopic records, and the areas of rima glottis openings were calculated with the Image-J programme. Forty-seven patients were analyzed. The mean pre-post-operative rima glottis areas were 1.11 ± 0.56 and 2.24 ± 0.93 mm(2), respectively (p < 0.001). Five patients with previous tracheotomy were decannulated within a few days after the operation. In three patients, mild complications developed in the early post-operative period (two laryngeal edemas, one submucosal hematoma). Tracheotomy was performed to only one pregnant patient in the post-operative first day. None of the patients had granulation formation or synechia.
Endoscopic diode-laser applications in airway surgery
NASA Astrophysics Data System (ADS)
Pankratov, Michail M.; Wang, Zhi; Rebeiz, Elie E.; Perrault, Donald F., Jr.; Shapshay, Stanley M.; Gleich, Lyon L.
1994-09-01
A technique was developed to secure small mucosal grafts onto the airway wound with fibrin/albumin tissue adhesive mixed with ICG dye and irradiated with a 810 nm diode laser. An in vitro study of the tensile strength produced strong mucosal soldering which was adequate to fix grafts in place. In vivo studies showed that wounds with mucosal grafts were completely covered by regenerated squamous cells in 1 week and by ciliated epithelium in 2 weeks. Excellent healing was observed at 6 and 14 days postoperatively and the histology at 28 days found normal epithelium over the vocal cord lesion. This soldering technique is a less traumatic treatment for patients with extensive lesions of the larynx of various origin. Diode laser soldering with ICG-doped fibrin tissue adhesive was evaluated in tracheal anastomosis as a substitute for absorbable sutures. In vitro studies demonstrated strong anastomoses with minimal tissue damage. In vivo animal study showed that these anastomoses had less fibrosis and tissue damage than control animals repaired with sutures only.
The "Hitch Stitch": An Effective Method of Preventing Migration in High Tracheal Stenosis.
Mehta, Ravindra M; Singla, Abhinav; Shah, Aashish; Loknath, Chakravarthi
2017-01-01
The incidence of caudal stent migration in high tracheal stenting is 13-21% and is common with silicone stents. This can lead to major problems, including emergency repeat procedures. Several antimigration methods are described, but have limitations in terms of their success rate, availability, cost or ease of the procedure. We describe an innovative method of stent migration prevention using a simple percutaneous anchoring "hitch stitch", validated in a large series. After tracheal stent placement, an Ethilon suture was passed into the stent lumen through an 18-G needle. To take this suture back to the exterior to complete the stitch, a retrieval loop was passed through another 14-G percutaneous cannula inserted into the stent lumen. Bronchoscopically, using a forceps the first suture was pulled inside the loop, the loop was retracted, the suture was exteriorized, and the knot was completed and embedded subcutaneously. While removing the stent, an endoscopic scissor was used to cut the stitch to free the stent. A total of 42 "hitch stitches" were done in 29 patients over 5 years, predominantly for silicone stents. Indications for stenting included postintubation tracheal stenosis (83.3%), malignancy (11.9%) and tracheoesophageal fistula (4.8%, metal stents). The procedure was successful in 41/42 (97.6%) patients. Stitch removal was uncomplicated. This is the largest series of an external stent anchoring procedure as a migration prevention strategy in high tracheal stenting, applicable to both silicone and metal stents. Stent migration prevention using this "hitch stitch" is simple, safe and successful, without any complications during stent removal. © 2016 S. Karger AG, Basel.
Early experience with totally robotic Roux-en-Y gastric bypass for morbid obesity.
Diamantis, Theodoros; Alexandrou, Andreas; Gouzis, Kostas; Alchanatis, Manos; Giannopoulos, Athanasios
2010-12-01
Laparoscopic Roux-en-Y gastric bypass (RYGBP) for morbid obesity is a challenging operation. The application of robotic techniques has been shown to ease the technical difficulties and reduce perioperative morbidity, mainly because it facilitates the construction of the gastrojejunal anastomosis (GJ). Robotic laparoscopic RYGBP (LRYGBP) has been reported either as totally robotic with manual suturing of the GJ or as robotically assisted with the use of the robot only for the construction of the GJ. A totally robotic LRYGBP with a combined stapled and manual GJ has never been reported. Nine consecutive patients underwent totally robotic LRYGBP. The GJ was fashioned with a combination of the linear stapler and manual suturing. Mean preoperative body mass index was 45.3 ± 4.7 kg/m(2). In 1 case, we had to undock the Da Vinci Surgical System at the time of the jejunojejunostomy due to unfavorable ergonomics. Mean time to dock the robot was 16.3 ± 3.3 minutes, whereas mean total operative time was 197.2 ± 12.3 minutes. Immediate postoperative morbidity and mortality equaled zero. One patient developed a stenosis of the GJ amenable to endoscopic dilatation. The mean excess weight loss rate 1-year postoperative was 79% ± 15%. Totally robotic LRYGBP can duplicate precisely any conventional technique without any compromise in operative time, short- or long-term results.
Fang, Chu-Wen; Tseng, Chun-Hung; Wu, Shih-Chi; Chen, William Tzu-Liang; Muo, Chih-Hsin
2017-12-01
The primary management of peptic ulcers is medical treatment. Persistent exacerbation of a peptic ulcer may lead to complications (perforation and/or bleeding). There has been a trend toward the use of a less invasive surgical simple suture, simple local suture or non-operative (endoscopic/angiography) hemostasis rather than acid-reducing vagotomy (i.e., vagus nerve severance) for treating complicated peptic ulcers. Other studies have shown the relationship between high vagus nerve activity and survival in cancer patients via reduced levels of inflammation, indicating the essential role of the vagus nerve. We were interested in the role of the vagus nerve and attempted to assess the long-term systemic effects after vagus nerve severance. Complicated peptic ulcer patients who underwent truncal vagotomy may represent an appropriate study population for investigating the association between vagus nerve severance and long-term effects. Therefore, we assessed the risks of subsequent ischemic stroke using different treatment methods in complicated peptic ulcer patients who underwent simple suture/hemostasis or truncal vagotomy/pyloroplasty. We selected 299,742 peptic ulcer patients without a history of stroke and Helicobacter pylori infection and an additional 299,742 matched controls without ulcer, stroke, and Helicobacter pylori infection from the National Health Insurance database. The controls were frequency matched for age, gender, Charlson comorbidity index (CCI) score, hypertension, hyperlipidemia history, and index year. Then, we measured the incidence of overall ischemic stroke in the two cohorts. The hazard ratio (HR) and the 95% confidence intervals (CIs) were estimated by Cox proportional hazard regression. Compared to the controls, peptic ulcer patients had a 1.86-fold higher risk of ischemic stroke. There were similar results in gender, age, CCI, hypertension, and hyperlipidemia stratified analyses. In complicated peptic ulcer patients, those who received truncal vagotomy and pyloroplasty had a lower risk of ischemic stroke than patients who received simple suture/hemostasis (HR = 0.70, 95% CI = 0.60-0.81). Our findings suggest that patients with peptic ulcers have an elevated risk of subsequent ischemic stroke. Moreover, there were associations between vagotomy and a decreased risk of subsequent ischemic stroke in complicated peptic ulcer patients.
Hiraki, Masatsugu; Ueda, Junji; Kono, Hiroshi; Egawa, Noriyuki; Saeki, Kiyoshi; Tsuru, Yasuhiro; Ide, Takao
2017-01-01
Abstract The use of laparoscopic surgery in the treatment of Mirizzi syndrome is considered controversial due to the degree of technical difficulty. We herein describe the case of a 36-year-old woman who was admitted to our hospital due to appetite loss, nausea and back pain. Endoscopic retrograde cholangiography revealed a round-shaped filling defect at the confluence of the bile duct. The patient was diagnosed with Mirizzi syndrome Type II according to the Csendes classification. Before surgery, an endoscopic nasobiliary drainage tube was placed for intraoperative cholangiography. Based on the intraoperative findings, the anterior wall of Hartmann’s pouch was excised to remove the impacted gallstone. The neck portion of the gallbladder wall was then used to make a gallbladder patch, which was sutured to cover the anterior wall of the common hepatic bile duct. Laparoscopic choledochoplasty using a gallbladder patch was a technically feasible treatment for Mirizzi syndrome Type II. PMID:29230280
Pratt, Janey S A; Van Noord, Michael; Christison-Lagay, Emily
2007-05-01
Known complications of Roux-en-Y gastric bypass causing abdominal pain and obstructive symptoms include biliary colic, anastomotic ulcer, anastomotic stenosis, or internal hernia. This case report describes a new complication in a patient 15 months post-bypass: a bezoar at the gastrojejunal anastomosis, the nidus of which was a length of permanent suture material which had eroded through the gastric wall. We include endoscopic images of the bezoar, a review of the related gastric bypass literature, and describe the changes made in our practice as a result of this complication.
Brunt, L Michael; Halpin, Valerie J; Klingensmith, Mary E; Tiemann, Debra; Matthews, Brent D; Spitler, Jennifer A; Pierce, Richard A
2008-05-01
Skills training plays an increasing role in residency training. Few medical schools have skills courses for senior students entering surgical residency. A skills course for 4(th)-year medical students matched in a surgical specialty was conducted in 2006 and 2007 during 7 weekly 3-hour sessions. Topics included suturing, knot tying, procedural skills (eg, chest tube insertion), laparoscopic skills, use of energy devices, and on-call management problems. Materials for outside practice were provided. Pre- and postcourse assessment of suturing skills was performed; laparoscopic skills were assessed postcourse using the Society of American Gastrointestinal and Endoscopic Surgeons' Fundamentals of Laparoscopic Surgery program. Students' perceived preparedness for internship was assessed by survey (1 to 5 Likert scale). Data are mean +/- SD and statistical analyses were performed. Thirty-one 4(th)-year students were enrolled. Pre- versus postcourse surveys of 45 domains related to acute patient management and technical and procedural skills indicated an improved perception of preparedness for internship overall (mean pre versus post) for 28 questions (p < 0.05). Students rated course relevance as "highly useful" (4.8 +/- 0.5) and their ability to complete skills as "markedly improved" (4.5 +/- 0.6). Suturing and knot-tying skills showed substantial time improvement pre- versus postcourse for 4 of 5 tasks: simple interrupted suturing (283 +/- 73 versus 243 +/- 52 seconds), subcuticular suturing (385 +/- 132 versus 274 +/- 80 seconds), 1-handed knot tying (73 +/- 33 versus 58 +/- 22 seconds), and tying in a restricted space (54 +/- 18 versus 44 +/- 16 seconds) (p < 0.02). Only 2-handed knot tying did not change substantially (65 +/- 24 versus 59 +/- 24 seconds). Of 13 students who took the Fundamentals of Laparoscopic Surgery skills test, 5 passed all 5 components and 3 passed 4 of 5 components. Skills instruction for senior students entering surgical internship results in a higher perception of preparedness and improved skills performance. Medical schools should consider integrating skills courses into the 4(th)-year curriculum to better prepare students for surgical residency.
[Conversional and endoscopic procedures following bariatric surgery].
Zorron, R; Bothe, C; Junghans, T; Pratschke, J; Benzing, C; Krenzien, F
2016-10-01
The Roux-en-Y gastric bypass (RYGB) is the therapy of choice in bariatric surgery. Sleeve gastrectomy and gastric banding are showing higher rates of treatment failure, reducing obesity-associated morbidity and body weight insufficiently. Moreover, gastroesophageal reflux disease (GERD) can occur refractory to medication. Therefore, a laparoscopic conversion to RYGB can be reasonable as long as specific conditions are fulfilled.Endoscopic procedures are currently being applied to revise bariatric procedures. Therapy failure following RYGB occurs in up to 20 % of cases. Transoral outlet reduction is the minimally invasive method of choice to reduce gastrojejunal anastomosis of the alimentary limb. The diameter of a gastric sleeve can be unwantedly enlarged as well; that can be reduced by placement of a longitudinal full-thickness suture.Severe hypoglycemic episodes can be present in patients following RYGB. Hypoglycemic episodes have to be diagnosed first and can be treated conventionally. Alternatively, a laparoscopic approach according to Branco-Zorron can be used for non-responders. Hypoglycemic episodes can thus be prevented and body weight reduction can be assured.Conversional and endoscopic procedures can be used in patients with treatment failure following bariatric surgery. Note that non-invasive approaches should have been applied intensively before a revisional procedure is performed.
Endoscope-assisted laparoscopic repair of perforated peptic ulcers.
Lee, Kun-Hua; Chang, Hung-Chi; Lo, Chong-Jeh
2004-04-01
Laparoscopic repairs for perforated peptic ulcer (PPU) are likely to fail in patients with shock, gastric outlet obstruction, or large perforations. This prospective study was performed to evaluate a revised approach of laparoscopic repair with endoscopic assistance to treat these patients. Between April 2001 and February 2002, 30 consecutive patients with PPU were enrolled in this study. The mean age was 43.1 +/- 12.2 years. Male to female ratio was 27:2. One patient was excluded from laparoscopic repair due to a gastric outlet obstruction. The other 29 patients were managed according to a protocol of preoperative upper endoscopy and laparoscopic intracorporeal suture repair with an omental patch. The average operative time was 58.1 +/- 13.5 minutes (range, 36-96 min). The average diameter of perforation was 4.2 +/- 2.0 mm (range, 1-12 mm). The average time to resume oral fluids was 3.2 +/- 0.8 days (range, 2-8 days). The average hospital stay was 4.7 +/- 1.1 days (range, 3-10 days). There was no leakage or mortality. Most patients did not receive parenteral analgesics postoperatively. We conclude that endoscope-assisted laparoscopic repair for PPU is safe and effective. This revised technique allows surgeons to exclude patients who are likely to fail the laparoscopic repair.
Comparison between suture anchor and transosseous suture for the modified-Broström procedure.
Cho, Byung-Ki; Kim, Yong-Min; Kim, Dong-Soo; Choi, Eui-Sung; Shon, Hyun-Chul; Park, Kyoung-Jin
2012-06-01
This prospective, randomized study was conducted to compare clinical outcomes of the modified Broström procedure using suture anchor or transosseous suture technique for chronic ankle instability. Forty patients were followed for more than 2 years after modified Broström procedure. Twenty procedures using a suture anchor and 20 procedures using a transosseous suture were performed by one surgeon. The clinical evaluation consisted of the Karlsson scale and the Sefton grading system. Talar tilt and anterior talar translation were measured on anterior and varus stress radiographs. The Karlsson scale had improved significantly to 90.8 points in the suture anchor group, and to 89.2 points in the transosseous suture group. According to Sefton grading system, 18 patients (90%) in suture anchor group and 17 patients (85%) in transosseous suture group achieved satisfactory results. The talar tilt angle and anterior talar translation improved significantly to 5.9 degrees and 4.2 mm in suture anchor group, and to 5.4 degrees and 4.1 mm in transosseous suture group, respectively. No significant differences existed in clinical and functional outcomes between the two techniques for ligament reattachment. Both modified Broström procedures using the suture anchor and transosseous suture seem to be effective treatment methods for chronic lateral ankle instability.
Wu, Shih-Chi; Fang, Chu-Wen; Chen, William Tzu-Liang; Muo, Chih-Hsin
2016-12-01
Persistent exacerbation of a peptic ulcer may lead to a complicated peptic ulcer (perforation or/and bleeding). The management of complicated peptic ulcers has shifted from acid-reducing vagotomy, drainage, and gastrectomy to simple local suture or non-operative (endoscopic/angiographic) hemostasis. We were interested in the long-term effects of this trend change. In this study, complicated peptic ulcer patients who received acid-reducing vagotomy were compared with those who received simple suture/hemostasis to determine the risk of ischemic heart disease (IHD).This retrospective cohort study analyzed 335,680 peptic ulcer patients recorded from 2000 to 2006 versus 335,680 age-, sex-, comorbidity-, and index-year matched comparisons. Patients with Helicobacter pylori (HP) infection were excluded. In order to identify the effect of vagus nerve severance, patients who received gastrectomy or antrectomy were also excluded. The incidence of IHD in both cohorts, and in the complicated peptic ulcer patients who received acid-reducing vagotomy versus those who received simple suture or hemostasis was evaluated.The overall incidence of IHD was higher in patients with peptic ulcer than those without peptic ulcer (17.00 vs 12.06 per 1000 person-years), with an adjusted hazard ratio (aHR) of 1.46 based on multivariable Cox proportional hazards regression analysis controlling for age, sex, Charlson's comorbidity index, and death (competing risk). While comparing peptic ulcer patients with acid-reducing vagotomy to those with simple suture/hemostasis or those without surgical treatment, the aHR (0.58) was the lowest in the acid-reducing vagotomy group.Patients with peptic ulcer have an elevated risk of IHD. However, complicated peptic ulcer patients who received acid-reducing vagotomy were associated with reduced risk of developing IHD.
Wu, Shih-Chi; Fang, Chu-Wen; Chen, William Tzu-Liang; Muo, Chih-Hsin
2016-01-01
Abstract Persistent exacerbation of a peptic ulcer may lead to a complicated peptic ulcer (perforation or/and bleeding). The management of complicated peptic ulcers has shifted from acid-reducing vagotomy, drainage, and gastrectomy to simple local suture or non-operative (endoscopic/angiographic) hemostasis. We were interested in the long-term effects of this trend change. In this study, complicated peptic ulcer patients who received acid-reducing vagotomy were compared with those who received simple suture/hemostasis to determine the risk of ischemic heart disease (IHD). This retrospective cohort study analyzed 335,680 peptic ulcer patients recorded from 2000 to 2006 versus 335,680 age-, sex-, comorbidity-, and index-year matched comparisons. Patients with Helicobacter pylori (HP) infection were excluded. In order to identify the effect of vagus nerve severance, patients who received gastrectomy or antrectomy were also excluded. The incidence of IHD in both cohorts, and in the complicated peptic ulcer patients who received acid-reducing vagotomy versus those who received simple suture or hemostasis was evaluated. The overall incidence of IHD was higher in patients with peptic ulcer than those without peptic ulcer (17.00 vs 12.06 per 1000 person-years), with an adjusted hazard ratio (aHR) of 1.46 based on multivariable Cox proportional hazards regression analysis controlling for age, sex, Charlson's comorbidity index, and death (competing risk). While comparing peptic ulcer patients with acid-reducing vagotomy to those with simple suture/hemostasis or those without surgical treatment, the aHR (0.58) was the lowest in the acid-reducing vagotomy group. Patients with peptic ulcer have an elevated risk of IHD. However, complicated peptic ulcer patients who received acid-reducing vagotomy were associated with reduced risk of developing IHD. PMID:27977613
Goel, Ruchi; Kishore, Divya; Nagpal, Smriti; Kumar, Sushil; Rathie, Neha
2017-01-01
Context: Conjunctivodacryocystorhinostomy (CDCR) is the procedure of choice for proximal canalicular blocks. However, the complications of tube migration and extrusion limit its widespread practice. Aim: The aim of this study is to evaluate the efficacy and complications of the new “mirror tuck technique” for fixation of lacrimal bypass glass tube without holes in proximal canalicular blocks in laser CDCR. Materials and Methods: A prospective interventional study was conducted in forty consecutive eyes of adult patients, undergoing 980 nm diode laser CDCR for proximal canalicular blocks. After creating the tract under endoscopic guidance, the collar of the glass tube was fixed to the conjunctiva with 6-0 prolene suture by “mirror tuck technique.” Success was defined as the absence of extrusion of tube with patent tract and relief in epiphora at 1 year of follow-up. Results: Both anatomical and functional success was achieved in 39 (97.5%) cases. Tube displacement occurred in one patient suffering from allergic conjunctivitis in which the tube had to be removed. A temporary heaviness was reported by 5 (12.5%) patients till about 2 weeks. Conjunctival overgrowth over the tube occurred in 1 (2.5%) eye at 5 months which was excised and treated with application of 0.02% mitomycin C with no subsequent recurrence. There were no cases of suture abscess or suture intolerance warranting tube removal. Conclusion: “Mirror tuck technique” is an effective method for tube fixation (for tube without holes) in CDCR. However, it is important to position the conjunctival opening so as to leave sufficient space for passage of sutures for anchorage medially. PMID:28513491
Transumbilical endoscopic surgery for incarcerated inguinal hernias in infants and children.
Zhou, Xuewu; Peng, Lei; Sha, Yongliang; Song, Daiqiang
2014-01-01
To describe transumbilical laparoscopic herniorrhaphy after unsuccessful attempted manual reduction of incarcerated inguinal hernias in infants and children. In our two hospitals, two-trocar transumbilical endoscopic surgery (TUES) is the standard technique used to repair incarcerated inguinal hernias in infants and children. Seventeen patients (aged 8months to 2.5years; median, 15months; 15 boys, 2 girls) with incarcerated inguinal hernias underwent urgent laparoscopy after unsuccessful attempted manual reduction. Two 3- or 5-mm trocars were inserted into the abdomen through two intraumbilical incisions, under laparoscopic guidance. The hernia was reduced by combined external manual pressure and internal pulling with bowel forceps. After inspection of the bowel, a round needle with a 2-0 nonabsorbable suture was introduced into the peritoneal cavity through the anterior abdominal wall near the internal inguinal ring. The hernial orifice was closed with an extraperitoneal purse-string suture around the internal inguinal ring, and tied with an intraperitoneal knot. A similar procedure was performed on the contralateral side if the processus vaginalis was patent. The TUES procedure was successful in all patients. No conversions to open surgery were required. The mean operating time was 30min (range, 25-40min). All patients were discharged on the second postoperative day. No complications such as postoperative bleeding, hydrocele, or scrotal edema were observed. The mean follow-up period was 15months. No cases of testicular atrophy, hypotrophy, or hernia recurrence were reported. Our preliminary experience with using TUES for the treatment of incarcerated inguinal hernias in infants and children had satisfactory outcomes. This technique appeared to be safe, effective, and reliable, and had excellent cosmetic results. Published by Elsevier Inc.
Hawkins, J F; Couetil, L; Miller, M A
2014-02-01
The objective was to evaluate CO2 laser debridement of the cricoarytenoid joint (CAJ) combined with prosthetic laryngoplasty to prevent post-operative loss of arytenoid abduction in seven horses. Horses were assigned to either laser debridement of the left CAJ and laryngoplasty (laser treated, n=5) or control laryngoplasty (sham, n=2), and were evaluated with endoscopic examinations and measurement of right to left angle quotients (RLQ) to assess maintenance of arytenoid abduction. The animals were euthanased at intervals after surgery and larynges were harvested for post-mortem testing, including determination of translaryngeal flow, pressure, impedance and RLQ. Measurements were obtained under increasing vacuum-generated negative pressure with laryngoplasty sutures intact and with the knot/crimp of the laryngoplasty sutures removed. Following post-mortem testing the cricoarytenoid joints were examined histologically. Post-operative endoscopic examinations revealed no significant differences between RLQ measurements calculated for day 1 following surgery to the termination date of the study for the seven horses. Post-mortem RLQ at airflows of 10 and 60 L/s was significantly higher in sham than in laser treated horses both before and after knot/crimp removal. Translaryngeal impedance at 10 and 60 L/s was not statistically different between groups. Histopathology revealed necrosis and loss of articular cartilage in the laser treated horses. The lymphoid cell infiltration subsided but joint capsule and periarticular fibrosis increased over the course of the study. Post-operative loss of arytenoid abduction after laryngoplasty can be minimized with CO2 laser debridement of the CAJ joint. Copyright © 2013 Elsevier Ltd. All rights reserved.
Smartphone-Based Endoscope System for Advanced Point-of-Care Diagnostics: Feasibility Study
Bae, Jung Kweon; Vavilin, Andrey; You, Joon S; Kim, Hyeongeun; Ryu, Seon Young; Jang, Jeong Hun
2017-01-01
Background Endoscopic technique is often applied for the diagnosis of diseases affecting internal organs and image-guidance of surgical procedures. Although the endoscope has become an indispensable tool in the clinic, its utility has been limited to medical offices or operating rooms because of the large size of its ancillary devices. In addition, the basic design and imaging capability of the system have remained relatively unchanged for decades. Objective The objective of this study was to develop a smartphone-based endoscope system capable of advanced endoscopic functionalities in a compact size and at an affordable cost and to demonstrate its feasibility of point-of-care through human subject imaging. Methods We developed and designed to set up a smartphone-based endoscope system, incorporating a portable light source, relay-lens, custom adapter, and homebuilt Android app. We attached three different types of existing rigid or flexible endoscopic probes to our system and captured the endoscopic images using the homebuilt app. Both smartphone-based endoscope system and commercialized clinical endoscope system were utilized to compare the imaging quality and performance. Connecting the head-mounted display (HMD) wirelessly, the smartphone-based endoscope system could superimpose an endoscopic image to real-world view. Results A total of 15 volunteers who were accepted into our study were captured using our smartphone-based endoscope system, as well as the commercialized clinical endoscope system. It was found that the imaging performance of our device had acceptable quality compared with that of the conventional endoscope system in the clinical setting. In addition, images captured from the HMD used in the smartphone-based endoscope system improved eye-hand coordination between the manipulating site and the smartphone screen, which in turn reduced spatial disorientation. Conclusions The performance of our endoscope system was evaluated against a commercial system in routine otolaryngology examinations. We also demonstrated and evaluated the feasibility of conducting endoscopic procedures through a custom HMD. PMID:28751302
Tsin, Daniel A; Davila, Fausto; Dominguez, Guillermo; Tinelli, Andrea; Davila, Martha R
2012-05-01
Use of secured independent tools (SIT) is changing the laparoscopy paradigm, which involves the use of instruments inside the abdominal cavity that are operated via a port that is larger in diameter than the instrument itself. However, in SIT instead of ports we used filaments or cables. Here we describe a modified SIT for use in the introduction of sutures or cables inside the peritoneum. Cables or sutures are passed through a tunnel made by an intravenous catheter and then exteriorized via a 12-mm port for tying, plugging (attaching), or connecting to different types of devices such as an endoscopic bulldog, alligator clamps, lights, and micromotors. These devices are introduced inside the abdomen and remotely operated with cables or filaments. The use of SIT is not limited to laparoscopy; it was successfully used in clinical experiences of single-port and single-incision laparoscopy and could facilitate natural orifice surgery. The technique offers a good force for traction, retraction, and mobilization. In addition, it has transmission capabilities for cameras and may facilitate the placement of wired microrobotics.
Bogni, Serge; Ortner, Maria-Anna; Vajtai, Istvan; Jost, Christian; Reinert, Michael; Dallemagne, Bernard; Frenz, Martin
2012-07-01
Complete closure of gastrotomy is the linchpin of safe natural orifice transgastric endoscopic surgery. To evaluate feasibility and efficacy of a new method of gastrotomy closure by using a sutureless laser tissue-soldering (LTS) technique in an ex vivo porcine stomach. In vitro experiment. Experimental laboratory. Histological analysis and internal and external liquid pressure with and without hydrochloric acid exposure were determined comparing gastrotomy closure with LTS and with hand-sewn surgical sutures. Comparison of LTS and hand-sewn surgical gastrotomy closure. The primary outcome parameter was the internal leak pressure. Secondary parameters were the difference between internal and external leak pressures, the impact of an acid environment on the device, histological changes, and feasibility of endoscopic placement. The internal liquid leak pressure after LTS was almost twice as high as after hand-sewn surgical closure (416 ± 53 mm Hg vs 229 ± 99 mm Hg; P = .01). The internal leak pressure (416 ± 53 mm Hg) after LTS was higher than the external leak pressure (154 ± 46 mm Hg; P < .0001). An acidic environment did not affect leak pressure after LTS. Endoscopic LTS closure was feasible in all experiments. Histopathology revealed only slight alterations beneath the soldering plug. In vitro experiments. Leak pressure after LTS closure of gastrotomy is higher than after hand-sewn surgical closure. LTS is a promising technique for closure of gastrotomies and iatrogenic perforations. Further experiments, in particular survival studies, are mandatory. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Current options in inguinal hernia repair in adult patients
Kulacoglu, H
2011-01-01
Inguinal hernia is a very common problem. Surgical repair is the current approach, whereas asymptomatic or minimally symptomatic hernias may be good candidate for watchful waiting. Prophylactic antibiotics can be used in centers with high rate of wound infection. Local anesthesia is a suitable and economic option for open repairs, and should be popularized in day-case setting. Numerous repair methods have been described to date. Mesh repairs are superior to "nonmesh" tissue-suture repairs. Lichtenstein repair and endoscopic/laparoscopic techniques have similar efficacy. Standard polypropylene mesh is still the choice, whereas use of partially absorbable lightweight meshes seems to have some advantages. PMID:22435019
Surgical management of peptic ulcer disease today--indication, technique and outcome.
Zittel, T T; Jehle, E C; Becker, H D
2000-03-01
The current surgical management of peptic ulcer disease and its outcome have been reviewed. Today, surgery for peptic ulcer disease is largely restricted to the treatment of complications. In peptic ulcer perforation, a conservative treatment trial can be given in selected cases. If laparotomy is necessary, simple closure is sufficient in the large majority of cases, and definitive ulcer surgery to reduce gastric acid secretion is no longer justified in these patients. Laparoscopic surgery for perforated peptic ulcer has failed to prove to be a significant advantage over open surgery. In bleeding peptic ulcers, definitive hemostasis can be achieved by endoscopic treatment in more than 90% of cases. In 1-2% of cases, immediate emergency surgery is necessary. Some ulcers have a high risk of re-bleeding, and early elective surgery might be advisable. Surgical bleeding control can be achieved by direct suture and extraluminal ligation of the gastroduodenal artery or by gastric resection. Benign gastric outlet obstruction can be controlled by endoscopic balloon dilatation in 70% of cases, but gastrojejunostomy or gastric resection are necessary in about 30% of cases. Elective surgery for peptic ulcer disease has been largely abandoned, and bleeding or obstructing ulcers can be managed safely by endoscopic treatment in most cases. However, surgeons will continue to encounter patients with peptic ulcer disease for emergency surgery. Currently, laparoscopic surgery has no proven advantage in peptic ulcer surgery.
Laparoscopic managment of common bile duct stones: our initial experience.
Aroori, S.; Bell, J. C.
2002-01-01
The management of choledocholithiasis has changed radically since the introduction of laparoscopic cholecystectomy. However, perceived technical difficulties have deterred many surgeons from treating common bile duct stones laparoscopically at the time of cholecystectomy. This has lead to reliance on endoscopic retrograde cholangiopancreatography followed by endoscopic sphincterotomy to deal with common bile duct stones. We retrospectively reviewed the charts of patients who had laparoscopic common bile duct exploration at Downe Hospital between December 1999 and August 2001. Among 149 laparoscopic cholecystectomies done by our group in this period, 10 patients (6.7%) underwent laparoscopic CBD exploration, three by the transcystic technique and seven by choledochotomy. Three patients (2%) had unsuspected stones found on routine per- operative cholangiogram. The mean operative time was 2.34hrs (range 1.50-3.30hrs). The mean hospital post- operative stay was 3 days (range 1-6 days). Post-operative morbidity was zero. Stone clearance was achieved in all cases. We conclude, laparoscopic exploration of the common bile duct is relatively safe and straightforward method. The key skill required is the ability to perform laparoscopic suturing with confidence. PMID:12137159
Laparoscopic managment of common bile duct stones: our initial experience.
Aroori, S; Bell, J C
2002-05-01
The management of choledocholithiasis has changed radically since the introduction of laparoscopic cholecystectomy. However, perceived technical difficulties have deterred many surgeons from treating common bile duct stones laparoscopically at the time of cholecystectomy. This has lead to reliance on endoscopic retrograde cholangiopancreatography followed by endoscopic sphincterotomy to deal with common bile duct stones. We retrospectively reviewed the charts of patients who had laparoscopic common bile duct exploration at Downe Hospital between December 1999 and August 2001. Among 149 laparoscopic cholecystectomies done by our group in this period, 10 patients (6.7%) underwent laparoscopic CBD exploration, three by the transcystic technique and seven by choledochotomy. Three patients (2%) had unsuspected stones found on routine per- operative cholangiogram. The mean operative time was 2.34hrs (range 1.50-3.30hrs). The mean hospital post- operative stay was 3 days (range 1-6 days). Post-operative morbidity was zero. Stone clearance was achieved in all cases. We conclude, laparoscopic exploration of the common bile duct is relatively safe and straightforward method. The key skill required is the ability to perform laparoscopic suturing with confidence.
Endoscopic-assisted osteotomies for the treatment of craniosynostosis.
Hinojosa, J; Esparza, J; Muñoz, M J
2007-12-01
The development of multidisciplinar units for Craniofacial Surgery has led to better postoperative results and a considerable decrease in morbidity in the treatment of complex craniofacial patients. Standard correction of craniosynostosis involves calvarial remodeling, often considerable blood losses that need to be replaced and lengthy hospital stay. The use of minimally invasive techniques for the correction of some of these malformations are widespread and allows the surgeon to minimize the incidence of complications by means of a decreased surgical time, blood salvage, and shortening of postoperative hospitalization in comparison to conventional craniofacial techniques. Simple and milder craniosynostosis are best approached by endoscopy-assisted osteotomies and render the best results. Extended procedures other than simple suturectomies have been described for more severe patients. Different osteotomies resembling standard fronto-orbital have been developed for the correction, and the use of postoperative cranial orthesis may improve the final cosmetic appearance. Thus, endoscopic-assisted procedures differ from the simple strategy of single suture resection that rendered insufficient results in the past, and different approaches can be tailored to solve these cases in patients in the setting of a case-to-case bases.
Mistry, N; Coulson, C; George, A
2017-11-01
Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.
Tensile strength and failure load of sutures for robotic surgery.
Abiri, Ahmad; Paydar, Omeed; Tao, Anna; LaRocca, Megan; Liu, Kang; Genovese, Bradley; Candler, Robert; Grundfest, Warren S; Dutson, Erik P
2017-08-01
Robotic surgical platforms have seen increased use among minimally invasive gastrointestinal surgeons (von Fraunhofer et al. in J Biomed Mater Res 19(5):595-600, 1985. doi: 10.1002/jbm.820190511 ). However, these systems still suffer from lack of haptic feedback, which results in exertion of excessive force, often leading to suture failures (Barbash et al. in Ann Surg 259(1):1-6, 2014. doi: 10.1097/SLA.0b013e3182a5c8b8 ). This work catalogs tensile strength and failure load among commonly used sutures in an effort to prevent robotic surgical consoles from exceeding identified thresholds. Trials were thus conducted on common sutures varying in material type, gauge size, rate of pulling force, and method of applied force. Polydioxanone, Silk, Vicryl, and Prolene, gauges 5-0 to 1-0, were pulled till failure using a commercial mechanical testing system. 2-0 and 3-0 sutures were further tested for the effect of pull rate on failure load at rates of 50, 200, and 400 mm/min. 3-0 sutures were also pulled till failure using a da Vinci robotic surgical system in unlooped, looped, and at the needle body arrangements. Generally, Vicryl and PDS sutures had the highest mechanical strength (47-179 kN/cm 2 ), while Silk had the lowest (40-106 kN/cm 2 ). Larger diameter sutures withstand higher total force, but finer gauges consistently show higher force per unit area. The difference between material types becomes increasingly significant as the diameters decrease. Comparisons of identical suture materials and gauges show 27-50% improvement in the tensile strength over data obtained in 1985 (Ballantyne in Surg Endosc Other Interv Tech 16(10):1389-1402, 2002. doi: 10.1007/s00464-001-8283-7 ). No significant differences were observed when sutures were pulled at different rates. Reduction in suture strength appeared to be strongly affected by the technique used to manipulate the suture. Availability of suture tensile strength and failure load data will help define software safety protocols for alerting a surgeon prior to suture failure during robotic surgery. Awareness of suture strength weakening with direct instrument manipulation may lead to the development of better techniques to further reduce intraoperative suture breakage.
Wei, Dechao; Han, Yili; Li, Mingchuan; Wang, Yongxing; Chen, Yatong; Luo, Yong; Jiang, Yongguang
2016-06-11
Among the different organs used for NOTES (natural orifice translumenal endoscopic surgery) technique, the transvaginal approach may be the optimal choice because of a simple and secure closure of colpotomy site. Pure and hybrid NOTES transvaginal operations were routinely performed via transperitoneal access. In this study, we investigate the safety and feasibility of pure retroperitoneal natural orifice translumenal endoscopic surgery (NOTES) transvaginal nephrectomy using conventional laparoscopic techniques in a porcine model. Six female pigs, weighing an average of 30 kg, were used in this study. Under general anesthesia, pure retroperitoneal NOTES transvaginal nephrectomy was conducted using standard laparoscopic instruments. Posterolateral colpotomy was performed, and the incision was enlarged laterally using blunt dissection and pneumatic dilation. A single-port device was inserted to construct the operative channel. The retroperitoneal space was created using sharp and blunt dissection under endoscopic guidance up to the level of the kidney. Dissection and removal of the kidney were performed according to standard surgical procedure, and the colpotomy site was closed using interrupted sutures. The survival and complications were observed 1 week postoperatively. Our results showed that two cases failed because of peritoneal rupture. One case was successful, but required the assistance of an extra 5 mm laparoscopic trocar inserted in the flank. Three cases of pure retroperitoneal NOTES transvaginal nephrectomy were completed, and survived 1 week after the operation. In these three cases, no intra- or postoperative complications were observed. All findings confirmed the safety and feasibility of the retroperitoneal pure retroperitoneal NOTES transvaginal nephrectomy using standard laparoscopic instruments, which suggested the possibility of clinical application in human beings in the future.
Transoral robotic surgery of craniocervical junction and atlantoaxial spine: a cadaveric study.
Lee, John Y K; O'Malley, Bert W; Newman, Jason G; Weinstein, Gregory S; Lega, Bradley; Diaz, Jason; Grady, M Sean
2010-01-01
The goal of this study was to determine the potential role and current limitations of the da Vinci surgical robot in transoral decompression of craniocervical junction (CCJ). The da Vinci Surgical System was used in 2 cadaver heads with neck and clavicles intact. Both neurosurgeons and otolaryngologists familiar with the open microscopic procedure, as well as the transoral robotic surgical procedure, undertook dissection and decompression of the CCJ. The robotic system provided superb illumination and 3D depth perception even several centimeters deep to the posterior oropharyngeal mucosa. The 30 degrees endoscope improved cephalad visualization, eliminating the need to split the soft palate for exposure of the lower clivus. The "intuitive" nature of the da Vinci surgical robot arms provided an advantage in allowing the ability to suture the dura mater in a deep, dark corridor. Because visualization was excellent, tremor-free closure was possible. The authors' findings suggest that transoral robotic surgery, with the da Vinci robot system, holds great potential for decompression of the CCJ as well as resection of both extra- and intradural tumors of this region. Further instrument development is necessary and continued investigation is warranted.
Holland, Pat; Shoop, Nancy M
2002-01-01
Flexible endoscopes are complex medical instruments that are easily damaged. In order to maintain the flexible endoscope in optimum working condition, the user must have a thorough understanding of the structure and function of the instrument. This is the fourth in a series of articles presenting an in-depth look at the care and handling of the flexible endoscope. The first three articles discussed the air-water system, the suction channel system, and the mechanical system. This article will focus specifically on the endoscopic retrograde cholangiopancreatography elevator system.
Flexible endoscopes: structure and function. The suction and biopsy channel.
Holland, P
2001-01-01
Flexible endoscopes are complex medical instruments that are easily damaged. To maintain the flexible endoscope in optimum working condition, the user must have a thorough understanding of the structure and function of the instrument. This is the second in a series of articles presenting an in-depth look at the care and handling of the flexible endoscope. The first article discussed the air and water system. This article will focus specifically on the suction and biopsy channel system. The flexible endoscope is constructed of several systems that operate simultaneously to produce a highly technical, yet effective diagnostic and therapeutic medical device. These systems include the air and water system, the suction or operating channel system, the mechanical system, the endoscopic retrograde cholangiopancreatography (ERCP) elevator system, the optical system, and the electrical system. A review of the internal and external structure of the flexible endoscope and the functions of the channel system, including infection control issues, potential problems and evaluation, and prevention of minor problems to avoid expensive repairs, will be addressed.
Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming
2014-01-01
Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.
Friedrich, D T; Sommer, F; Scheithauer, M O; Greve, J; Hoffmann, T K; Schuler, P J
2017-12-01
Objective Advanced transnasal sinus and skull base surgery remains a challenging discipline for head and neck surgeons. Restricted access and space for instrumentation can impede advanced interventions. Thus, we present the combination of an innovative robotic endoscope guidance system and a specific endoscope with adjustable viewing angle to facilitate transnasal surgery in a human cadaver model. Materials and Methods The applicability of the robotic endoscope guidance system with custom foot pedal controller was tested for advanced transnasal surgery on a fresh frozen human cadaver head. Visualization was enabled using a commercially available endoscope with adjustable viewing angle (15-90 degrees). Results Visualization and instrumentation of all paranasal sinuses, including the anterior and middle skull base, were feasible with the presented setup. Controlling the robotic endoscope guidance system was effectively precise, and the adjustable endoscope lens extended the view in the surgical field without the common change of fixed viewing angle endoscopes. Conclusion The combination of a robotic endoscope guidance system and an advanced endoscope with adjustable viewing angle enables bimanual surgery in transnasal interventions of the paranasal sinuses and the anterior skull base in a human cadaver model. The adjustable lens allows for the abandonment of fixed-angle endoscopes, saving time and resources, without reducing the quality of imaging.
Management of cystic echinococcosis complications and dissemination: where is the evidence?
Dziri, Chadli; Haouet, Karim; Fingerhut, Abe; Zaouche, Abdeljelil
2009-06-01
This systematic review was designed to provide "evidence-based" answers to identify the best treatment for a complicated hydatid cyst of the liver and the appropriate management of disseminated cystic echinococcosis. An extensive electronic search of the relevant literature was performed using Medline and the Cochrane Library. This systematic review enabled us make to determine the best treatment options for the following conditions. Liver hydatid cysts ruptured into the biliary tract: Common bile duct exploration should be conducted using intraoperative cholangiography and choledoscopy. When the biliary tract is cleared of all cystic content, T-tube drainage should be sufficient. The principal difficulty concerned the management of the large biliocystic fistula: suture or internal transfistulary drainage or fistulization. Medical treatment is indicated in association with surgery for 3 months postoperatively. During the preoperative period, endoscopic retrograde cholangiopancreatography (ERCP) combined with preoperative endoscopic sphincterotomy (ES) may decrease the incidence of postoperative external fistula. Liver hydatid cysts involving the thorax: An abdominal approach is mandatory when common bile duct drainage is required, and it may be sufficient to treat a direct rupture into bronchi. An acute abdomen, owing to Liver hydatid cysts ruptured into peritoneum, requires an emergent operation. Medical treatment should be associated. Cystic echinococcosis of the lung: Surgery is still the main therapeutic option to remove the cyst, suture bronchial fistula if necessary, followed by capitonnage. Osseous cystic echinococcosis: Wide surgical excision is recommended. Cystic echinococcosis of the heart: Cystopericystectomy is the "gold standard" procedure but is sometimes unsuitable for particular sites. Cystic echinococcosis of the kidney: Cystectomy with pericystectomy is feasible in 75% of cases; nephrectomy must be reserved for destroyed kidney. Multiple associated cystic echinococcosis locations: Complicated cysts should be treated with high priority. In case of several cysts in the liver, spleen, and peritoneum, removal of all cysts in the same intervention is indicated when there is no threat to the life of the patient. Otherwise, a planned reoperation should be considered.
Ngamruengphong, Saowanee; Sharaiha, Reem; Sethi, Amrita; Siddiqui, Ali; DiMaio, Christopher J.; Gonzalez, Susana; Rogart, Jason; Jagroop, Sophia; Widmer, Jessica; Im, Jennifer; Hasan, Raza Abbas; Laique, Sobia; Gonda, Tamas; Poneros, John; Desai, Amit; Wong, Katherine; Villgran, Vipin; Brewer Gutierrez, Olaya; Bukhari, Majidah; Chen, Yen-I; Hernaez, Ruben; Hanada, Yuri; Sanaei, Omid; Agarwal, Amol; Kalloo, Anthony N.; Kumbhari, Vivek; Singh, Vikesh; Khashab, Mouen A.
2018-01-01
Background and study aims Self-expandable metallic stents (SEMS) have been increasingly used in benign conditions (e. g. strictures, fistulas, leaks, and perforations). Fully covered SEMS (FSEMS) were introduced to avoid undesirable consequences of partially covered SEMS (PSEMS), but come with higher risk of stent migration. Endoscopic suturing (ES) for stent fixation has been shown to reduce migration of FSEMS. Our aim was to compare the outcomes of FSEMS with ES (FS/ES) versus PSEMS in patients with benign upper gastrointestinal conditions. Patients and methods We retrospectively identified all patients who underwent stent placement for benign gastrointestinal conditions at seven US tertiary-care centers. Patients were divided into two groups: FSEMS with ES (FS/ES group) and PSEMS (PSEMS group). Clinical outcomes between the two groups were compared. Results A total of 74 (FS/ES 46, PSEMS 28) patients were included. On multivariable analysis, there was no significant difference in rate of stent migration between FS/ES (43 %) and PSEMS (15 %) (adjusted odds ratio 0.56; 95 % CI 0.15 – 2.00). Clinical success was similar [68 % vs. 64 %; P = 0.81]. Rate of adverse events (AEs) was higher in PSEMS group [13 (46 %) vs. 10 (21 %); P = 0.03). Difficult stent removal was higher in the PSEMS group (n = 5;17 %) vs. 0 % in the FS/ES group; P = 0.005. Conclusions The proportion of stent migration of FS/ES and PSEMS are similar. Rates of other stent-related AEs were higher in the PSEMS group. PSEMS was associated with tissue ingrowth or overgrowth leading to difficult stent removal, and secondary stricture formation. Thus, FSEMS with ES for stent fixation may be the preferred modality over PSEMS for the treatment of benign upper gastrointestinal conditions. PMID:29404384
Stefanidis, Dimitrios; Hope, William W; Scott, Daniel J
2011-07-01
The value of robotic assistance for intracorporeal suturing is not well defined. We compared robotic suturing with laparoscopic suturing on the FLS model with a large cohort of surgeons. Attendees (n=117) at the SAGES 2006 Learning Center robotic station placed intracorporeal sutures on the FLS box-trainer model using conventional laparoscopic instruments and the da Vinci® robot. Participant performance was recorded using a validated objective scoring system, and a questionnaire regarding demographics, task workload, and suturing modality preference was completed. Construct validity for both tasks was assessed by comparing the performance scores of subjects with various levels of experience. A validated questionnaire was used for workload measurement. Of the participants, 84% had prior laparoscopic and 10% prior robotic suturing experience. Within the allotted time, 83% of participants completed the suturing task laparoscopically and 72% with the robot. Construct validity was demonstrated for both simulated tasks according to the participants' advanced laparoscopic experience, laparoscopic suturing experience, and self-reported laparoscopic suturing ability (p<0.001 for all) and according to prior robotic experience, robotic suturing experience, and self-reported robotic suturing ability (p<0.001 for all), respectively. While participants achieved higher suturing scores with standard laparoscopy compared with the robot (84±75 vs. 56±63, respectively; p<0.001), they found the laparoscopic task more physically demanding (NASA score 13±5 vs. 10±5, respectively; p<0.001) and favored the robot as their method of choice for intracorporeal suturing (62 vs. 38%, respectively; p<0.01). Construct validity was demonstrated for robotic suturing on the FLS model. Suturing scores were higher using standard laparoscopy likely as a result of the participants' greater experience with laparoscopic suturing versus robotic suturing. Robotic assistance decreases the physical demand of intracorporeal suturing compared with conventional laparoscopy and, in this study, was the preferred suturing method by most surgeons. Curricula for robotic suturing training need to be developed.
Anastomotic stenoses occurring after circular stapling in esophageal cancer surgery.
Petrin, G; Ruol, A; Battaglia, G; Buin, F; Merigliano, S; Constantini, M; Pavei, P; Cagol, M; Scappin, S; Ancona, E
2000-07-01
Circular staplers have reduced the incidence of anastomotic leaks in esophagovisceral anastomosis. However, the prevalence of stenosis is greater with staplers than with manual suturing. The aim of this study was to analyze potential risk factors for the onset of anastomotic stenoses and to evaluate their treatment and final outcome. Between 1990 and 1995, 187 patients underwent esophagectomy and esophagogastrostomy with anastomosis performed inside the chest using a circular stapler. Twenty-three patients (12.3%) developed an anastomotic stenosis. The incidence of strictures was inversely related to the diameter of the stapler. Concomitant cardiovascular diseases; morphofunctional disorders of the tubulized stomach, such as those related to duodenogastric reflux; and neoadjuvant chemotherapy were also recognized as significant risk factors. Endoscopic dilatations proved safe and were effective in the treatment of most anastomotic stenoses. To reduce the risk of anastomotic stenosis after stapled intrathoracic esophagogastrostomy, adequate vascularization of the viscera being anastomized should be maintained, and it is mandatory to use the largest circular stapler suitable. Furthermore, it is essential to reduce the negative inflammation-inducing effects of duodenogastroesophageal reflux to a minimum. Endoscopic dilatations are safe and effective in curing the great majority of anastomotic stenoses.
[Surgical tactics in duodenal trauma].
Ivanov, P A; Grishin, A V
2004-01-01
Results of surgical treatment of 61 patients with injuries of the duodenum are analyzed. The causes of injuries were stab-incised wounds in 24 patients, missile wound -- in 7, closed abdominal trauma -- in 26, trauma of the duodenum during endoscopic papillosphincterotomy -- in 4. All the patients underwent surgery. Complications were seen in 32 (52.5%) patients, 21 patients died, lethality was 34.4%. Within the first 24 hours since the trauma 7 patients died due to severe combined trauma, blood loss, 54 patients survived acute period of trauma, including 28 patients after open trauma, 26 -- after closed and 4 -- after trauma of the duodenum during endoscopic papillosphincterotomy. Diagnostic and surgical policies are discussed. Results of treatment depending on kind and time of surgery are regarded. It is demonstrated that purulent complications due to retroperitoneal phlegmona, traumatic pancreatitis, pneumonia are the causes of significant number of unfavorable outcomes. Therefore, it is important to adequately incise and drainage infected parts of retroperitoneal fat tissue with two-lumen drainages. Decompression through duodenal tube is the effective procedure for prophylaxis of suture insufficiency and traumatic pancreatitis. Suppression of pancreatic and duodenal secretion with octreotid improves significantly surgical treatment results.
Technological innovation in video-assisted thoracic surgery.
Özyurtkan, Mehmet Oğuzhan; Kaba, Erkan; Toker, Alper
2017-01-01
The popularity of video-assisted thoracic surgery (VATS) which increased worldwide due to the recent innovations in thoracic surgical technics, equipment, electronic devices that carry light and vision and high definition monitors. Uniportal VATS (UVATS) is disseminated widely, creating a drive to develop new techniques and instruments, including new graspers and special staplers with more angulation capacities. During the history of VATS, the classical 10 mm 0° or 30° rigid rod lens system, has been replaced by new thoracoscopes providing a variable angle technology and allowing 0° and 120° range of vision. Besides, the tip of these novel thoracoscopes can be positioned away from the operating side minimize fencing with other thoracoscopic instruments. The curved-tip stapler technology, and better designed endostaplers helped better dissection, precision of control, more secure staple lines. UVATS also contributed to the development of embryonic natural orifice transluminal endoscopic surgery. Three-dimensional VATS systems facilitated faster and more accurate grasping, suturing, and dissection of the tissues by restoring natural 3D vision and the perception of depth. Another innovation in VATS is the energy-based coagulative and tissue fusion technology which may be an alternative to endostaplers.
Endoscopic Transsphenoidal Cisternostomy for Nonneoplastic Sellar Cysts
Su, Yukai; Ishii, Yudo; Lin, Chien-Min; Tahara, Shigeyuki; Teramoto, Akira; Morita, Akio
2015-01-01
Background and Importance. Sellar arachnoid cysts and Rathke's cleft cysts are benign lesions that produce similar symptoms, including optochiasmatic compression, pituitary dysfunction, and headache. Studies have reported the use of various surgical treatment methods for treating these symptoms, preventing recurrence, and minimizing operative complications. However, the postoperative cerebrospinal fluid (CSF) fistula and recurrence rate remain significant. Clinical Presentation. In this paper, we present 8 consecutive cases involving arachnoid cysts and Rathke's cleft cysts, which were managed by using drainage and cisternostomy, the intentional fenestration of the cyst into the subarachnoid space, and then meticulously closing sellar floor using dural sutures. The postoperative images, CSF fistula rate, and the recurrence rate were favorable. Conclusion. We report this technique and discuss the benefit of this minimally invasive approach. PMID:25685785
A Haptic Guided Robotic System for Endoscope Positioning and Holding.
Cabuk, Burak; Ceylan, Savas; Anik, Ihsan; Tugasaygi, Mehtap; Kizir, Selcuk
2015-01-01
To determine the feasibility, advantages, and disadvantages of using a robot for holding and maneuvering the endoscope in transnasal transsphenoidal surgery. The system used in this study was a Stewart Platform based robotic system that was developed by Kocaeli University Department of Mechatronics Engineering for positioning and holding of endoscope. After the first use on an artificial head model, the system was used on six fresh postmortem bodies that were provided by the Morgue Specialization Department of the Forensic Medicine Institute (Istanbul, Turkey). The setup required for robotic system was easy, the time for registration procedure and setup of the robot takes 15 minutes. The resistance was felt on haptic arm in case of contact or friction with adjacent tissues. The adaptation process was shorter with the mouse to manipulate the endoscope. The endoscopic transsphenoidal approach was achieved with the robotic system. The endoscope was guided to the sphenoid ostium with the help of the robotic arm. This robotic system can be used in endoscopic transsphenoidal surgery as an endoscope positioner and holder. The robot is able to change the position easily with the help of an assistant and prevents tremor, and provides a better field of vision for work.
A technical review of flexible endoscopic multitasking platforms.
Yeung, Baldwin Po Man; Gourlay, Terence
2012-01-01
Further development of advanced therapeutic endoscopic techniques and natural orifice translumenal endoscopic surgery (NOTES) requires a powerful flexible endoscopic multitasking platform. Medline search was performed to identify literature relating to flexible endoscopic multitasking platform from year 2004-2011 using keywords: Flexible endoscopic multitasking platform, NOTES, Instrumentation, Endoscopic robotic surgery, and specific names of various endoscopic multitasking platforms. Key articles from articles references were reviewed. Flexible multitasking platforms can be classified as either mechanical or robotic. Purely mechanical systems include the dual channel endoscope (DCE) (Olympus), R-Scope (Olympus), the EndoSamurai (Olympus), the ANUBIScope (Karl-Storz), Incisionless Operating Platform (IOP) (USGI), and DDES system (Boston Scientific). Robotic systems include the MASTER system (Nanyang University, Singapore) and the Viacath (Hansen Medical). The DCE, the R-Scope, the EndoSamurai and the ANUBIScope have integrated visual function and instrument manipulation function. The IOP and DDES systems rely on the conventional flexible endoscope for visualization, and instrument manipulation is integrated through the use of a flexible, often lockable, multichannel access device. The advantage of the access device concept is that it allows optics and instrument dissociation. Due to the anatomical constrains of the pharynx, systems are designed to have a diameter of less than 20 mm. All systems are controlled by traction cable system actuated either by hand or by robotic machinery. In a flexible system, this method of actuation inevitably leads to significant hysteresis. This problem will be accentuated with a long endoscope such as that required in performing colonic procedures. Systems often require multiple operators. To date, the DCE, the R-Scope, the IOP, and the Viacath system have data published relating to their application in human. Alternative forms of instrument actuation, camera control and master console ergonomics should be explored to improve instrument precision, sphere of action, size and minimize assistance required. Copyright © 2012 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Endoscopic repair of tears of the superficial layer of the distal triceps tendon.
Heikenfeld, Roderich; Listringhaus, Rico; Godolias, Georgios
2014-07-01
The purpose of this study was to evaluate the results after endoscopic repair of partial superficial layer triceps tendon tears. Fourteen patients treated surgically between July 2005 and December 2012 were studied prospectively for 12 months. Indication for surgery was a partial detachment of the triceps tendon from the olecranon that was proved by magnetic resonance imaging (MRI) in all cases. Ten of these patients had chronic olecranon bursitis. All patients were treated with endoscopic surgery including bursectomy and repair of the distal triceps tendon with double-loaded suture anchors. Clinical examination of the patients as well as functional and subjective scores (Mayo Elbow Performance Index [MEPI], Disabilities of the Arm, Shoulder and Hand Score [Quick DASH]) were obtained preoperatively and postoperatively at 6 and 12 months. An isokinetic strength measurement and MRI were performed preoperatively and 12 months after surgery. All 14 patients were completely evaluated. The MEPI and Quick DASH Score improved significantly after the repair at all postoperative examinations. The MEPI gained 29 points, up to 96 points at last follow-up (P < .05), and the Quick DASH Score went down 15.6 points after 12 months to 4.5 points (P < .05). Maximum extension power improved 55.8%, up to 94.7% at last follow-up compared with the contralateral side. Using MRI, we found one reruptured partial tear of the triceps tendon that did not require revision surgery. Although triceps tendon ruptures are generally uncommon, partial superficial tears might be more common than previously described. Once the diagnosis is made, endoscopic repair is a method leading to good clinical results with improved function of the affected elbow. Endoscopic repair of superficial tears of the triceps tendon is able to restore function and strength and leads to excellent clinical results after 1 year. Strength recovers to nearly that of the contralateral side, and serious complications appear to be infrequent. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Qiao, Xiaofang; Li, Jinlong; Xu, Hua; Wan, Xin; Zhu, Jiaming
2017-08-25
To investigate the efficacy of combined laparoscopic-endoscopic lower esophageal sphincterotomy and modified Dor fundoplication for cardiochalasia patients. Clinical data of 11 cardiochalasia patients who underwent combined laparoscopic-endoscopic lower esophageal sphincterotomy and modified Dor fundoplication by the same medical team from January 2015 to December 2016 at The Second Hospital of Jilin University were retrospectively analyzed. The procedure was as follows: an incision was made in the anterior wall of esophagus and dissection of esophageal muscular layer was performed, then the bulged esophageal mucosa was covered by the fundus after 180 degrees fold to the right (fundoplication), finally the gastric fundus was joined to the right diaphragmatic foot by 3 to 5 knotted suture. The efficacy was judged by the Eckardt scoring standard: the postoperative Eckardt score ≤3 points indicated effectiveness, otherwise the treatment was invalid. Combined laparoscopic-endoscopic lower esophageal sphincterotomy and modified Dor fundoplication was completed successfully in all the 11 patients without any subsequent laparotomy and death. The mean operative time was 85 (78 to 137) min, blood loss was 15 (5 to 35) ml, and no upper digestive tract perforation occurred. The mean postoperative hospital stay was 7.0(6 to 9) d. After the operation, the pressure of lower esophageal sphincter decreased significantly compared to that before operation [(5.31±6.23) mmHg vs. (35.72±17.13) mmHg, P<0.05], and the Eckardt score decreased significantly as well (0.53±0.56 vs. 6.17±1.17, P<0.05). During the follow-up of 2 to 23 months, there was no postoperative mortality. One case experienced mild gastroesophageal reflux 6 months after operation, and another patient had recurrent dysphagia 17 months after operation, who both were improved after receiving proton pump inhibitors or gastric dynamic drugs, and balloon dilation. Combined laparoscopic-endoscopic lower esophageal sphincterotomy and modified Dor fundoplication is an effective and safe surgical procedure for cardiochalasia with minimal invasion and fast recovery.
The proposal of the locomotive system for capsule endoscopes.
Watada, Masaya; Ozawa, Ken-ichi
2008-01-01
The capsule endoscope authorized in some countries in late years has the advantage of preparing the observation in difficult small intestines in a past endoscope. However, because the promotion mechanism of a capsule endoscope depends only on the peristaltic motion of a digestive organ, the oversight of change to a morbid state is feared. Authors aim at the achievement of a free movement and remote diagnoses in small intestines, and are developing a locomotive system for capsule endoscopes. This paper describes the proposal of the locomotive system with an electromagnetic actuator, and examination of a simulation model for this locomotive system.
Robotic assisted Roux-en-Y hepaticojejunostomy in a post-cholecystectomy type E2 bile duct injury
Prasad, Arun; De, Sudipto; Mishra, Purak; Tiwari, Abhishek
2015-01-01
Roux-en-Y hepaticojejunostomy anastomosis is the treatment of choice for common hepatic duct injury type E2. It has been performed laparoscopically with the advancement of laparoscopic skill. Recently, a telemanipulative robotic surgical system was introduced, providing laparoscopic instruments with wrist-arm technology and 3-dimensional visualization of the operative field. We present a case of 36-year-old female patient who had undergone elective cholecystectomy 2 mo ago for gall stones and had a common bile duct injury during surgery. As the stricture was old and complete it could not be tackled endoscopically. We did a laparoscopic assisted adhesiolysis followed by robotic Roux-en-Y hepaticojejunostomy. No intraoperative complications or technical problems were encountered. Postoperative period was uneventful and she was discharged on the 4th postoperative day. At follow-up, she is doing well without evidence of jaundice or cholangitis. This is the first reported case of robotic hepaticojejunostomy following common bile duct injury. The hybrid technique gives the patient benefit of laparoscopic adhesiolysis and robotic suturing. PMID:25684934
[Cervical tracheal resection with primary anastomosis for benign tracheal stricture in adult].
Ye, Jin; Hu, Yan-Ming; Liu, Hui; Li, Jing-Jia; Wang, Zhi-Yuan; Li, Yuan
2013-07-01
To introduce the outcomes of tracheal resection with primary end to end anastomosis for benign cervical tracheal stenosis, and to discuss the strategy for prevention of surgical complications. A retrospective analysis was performed in 12 patients diagnosed as benign cervical tracheal stenosis from October 2009 to June 2012. Laryngo-tracheal endoscopic examination and computed tomography (CT) were used to assess the degree of stenosis, the grade of inflammation and edema of the subglottis and trachea, and the extent of stenosis and the remaining linear amount of normal airway. The Meyer and Cotton grading system was used to categorise the clinical severity of the stenoses. All patients underwent tracheal resection with primary end to end anastomosis. The length of cervical tracheal stenosis ranged from 2.3 to 4.1 cm. Grade II stenosis was present in three patients, Grade III stenosis was present in seven patients and grade IV stenosis in two patients. Successful extubation was achieved in all 12 cases. After surgery, temporary hoarseness occurred in 1 patient (8.3%); unilateral pulmonary atelectasis with pleural effusion occurred in 1 patient (8.3%); subcutaneous emphysema with infection occurred in 1 patient (8.3%); mild dysphagia occurred in 3 patients (25.0%); a slight deepening of the tone of voice occurred in 5 patients (41.7%), granulation tissue growth near the suture occurred in 3 patients (25.0%), and suture dehiscence did not occur in any patient. The follow-up period ranged from 6 months to 38 months, no patient developed restenosis. It presents a high success rate and good functional result of tracheal resection with primary end-to-end anastomosis. Therefore, it is an effective and reliable approach for the management of benign cervical tracheal stenosis. To avoid complications, the preoperative assessment, patients selection and postoperative management should be emphasized.
Endoscopes with latest technology and concept.
Gotoh
2003-09-01
Endoscopic imaging systems that perform as the "eye" of the operator during endoscopic surgical procedures have developed rapidly due to various technological developments. In addition, since the most recent turn of the century robotic surgery has increased its scope through the utilization of systems such as Intuitive Surgical's da Vinci System. To optimize the imaging required for precise robotic surgery, a unique endoscope has been developed, consisting of both a two dimensional (2D) image optical system for wider observation of the entire surgical field, and a three dimensional (3D) image optical system for observation of the more precise details at the operative site. Additionally, a "near infrared radiation" endoscopic system is under development to detect the sentinel lymph node more readily. Such progress in the area of endoscopic imaging is expected to enhance the surgical procedure from both the patient's and the surgeon's point of view.
Song, Dongzhe; Zhang, Fugui; Reid, Russell R; Ye, Jixing; Wei, Qiang; Liao, Junyi; Zou, Yulong; Fan, Jiaming; Ma, Chao; Hu, Xue; Qu, Xiangyang; Chen, Liqun; Li, Li; Yu, Yichun; Yu, Xinyi; Zhang, Zhicai; Zhao, Chen; Zeng, Zongyue; Zhang, Ruyi; Yan, Shujuan; Wu, Tingting; Wu, Xingye; Shu, Yi; Lei, Jiayan; Li, Yasha; Zhang, Wenwen; Wang, Jia; Lee, Michael J; Wolf, Jennifer Moriatis; Huang, Dingming; He, Tong-Chuan
2017-11-01
The cranial suture complex is a heterogeneous tissue consisting of osteogenic progenitor cells and mesenchymal stem cells (MSCs) from bone marrow and suture mesenchyme. The fusion of cranial sutures is a highly coordinated and tightly regulated process during development. Craniosynostosis is a congenital malformation caused by premature fusion of cranial sutures. While the progenitor cells derived from the cranial suture complex should prove valuable for studying the molecular mechanisms underlying suture development and pathogenic premature suture fusion, primary human cranial suture progenitors (SuPs) have limited life span and gradually lose osteoblastic ability over passages. To overcome technical challenges in maintaining sufficient and long-term culture of SuPs for suture biology studies, we establish and characterize the reversibly immortalized human cranial suture progenitors (iSuPs). Using a reversible immortalization system expressing SV40 T flanked with FRT sites, we demonstrate that primary human suture progenitor cells derived from the patent sutures of craniosynostosis patients can be efficiently immortalized. The iSuPs maintain long-term proliferative activity, express most of the consensus MSC markers and can differentiate into osteogenic and adipogenic lineages upon BMP9 stimulation in vitro and in vivo. The removal of SV40 T antigen by FLP recombinase results in a decrease in cell proliferation and an increase in the endogenous osteogenic and adipogenic capability in the iSuPs. Therefore, the iSuPs should be a valuable resource to study suture development, intramembranous ossification and the pathogenesis of craniosynostosis, as well as to explore cranial bone tissue engineering. © 2017 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.
Balkhy, Husam H; Nisivaco, Sarah M; Husain, Aliya N; Jeevanandam, Valluvan; Arif, Quidsia
Coronary artery bypass surgery is most commonly performed using a hand-sewn technique with a continuous monofilament suture. The C-Port distal anastomotic device is a miniature stapler designed to create an arteriotomy and attach the graft to the coronary artery all in one step. It is the only distal coronary anastomotic device currently approved for clinical use and can be useful in facilitating less invasive coronary surgery. This report examines the histological attributes of such an anastomosis in a patient who underwent heart transplantation approximately 1 year after robotic totally endoscopic stapled coronary bypass using the C-Port anastomotic device. There have been no previous reports of histological examination of this type of bypass graft in humans in the literature. We found that the C-Port single-shot stapled coronary anastomotic device had a similar histological appearance to a traditional hand-sewn technique using monofilament suture. The amount of inflammation around the anastomosis using the two techniques was found to be comparable in this histological case study in an explanted human heart. There was no evidence of increased neointimal hyperplasia. These findings add to the already known equivalent clinical patency rates of the C-Port device in coronary bypass procedures.
Gaspardone, Achille; De Marco, Federico; Sgueglia, Gregory A; De Santis, Antonella; Iamele, Maria; D'Ascoli, Emanuela; Tusa, Maurizio; Corciu, Anca; Mullen, Michael; Nobles, Anthony; Carminati, Mario; Bedogni, Francesco
2018-04-03
To assess the efficacy of a novel percutaneous "device-less" suture mediated patent foramen ovale (PFO) closure system. Between June 2016 and October 2017, a prospective registry aimed at assessing the safety and efficacy of the NobleStitch EL (HeartStitch, Fountain Valley, CA) suture-based PFO closure system was carried out at 12 sites in Italy. Among 200 consecutive evaluated patients, 192 were considered suitable for suture-mediated PFO closure (44±13 years, 114 women). Suture of the septum with the NobleStitch EL system was carried out successfully in 186 (96%) patients. Median fluoroscopy time was 16.1 (13.0-22.5) minutes and contrast volume 200 (150-270) ml. At 206±130 days follow-up, microbubbles transthoracic echocardiography with Valsalva maneuver revealed no RLS (grade 0) in 139 (75%) patients and RLS grade ≤1 in 166 (89%) patients. Significant RLS was present in 20 (11%) patients (grade 2 and 3 in 11 and 9 patients, respectively). There were no device-related complications. The early results of this first Italian Registry indicates that the suture mediated "deviceless" closure of PFO is feasible in the majority of septal anatomies, provides an effective closure of PFO comparable to traditional devices with an excellent safety profile at medium term follow-up.
Antibacterial Surgical Silk Sutures Using a High-Performance Slow-Release Carrier Coating System.
Chen, Xiaojie; Hou, Dandan; Wang, Lu; Zhang, Qian; Zou, Jiahan; Sun, Gang
2015-10-14
Sutures are a vital part for surgical operation, and suture-associated surgical site infections are an important issue of postoperative care. Antibacterial sutures have been proved to reduce challenging complications caused by bacterial infections. In recent decades, triclosan-free sutures have been on their way to commercialization. Alternative antibacterial substances are becoming relevant to processing surgical suture materials. Most of the antibacterial substances are loaded directly on sutures by dipping or coating methods. The aim of this study was to optimize novel antibacterial braided silk sutures based on levofloxacin hydrochloride and poly(ε-caprolactone) by two different processing sequences, to achieve suture materials with slow-release antibacterial efficacy and ideal physical and handling properties. Silk strands were processed into sutures on a circular braiding machine, and antibacterial treatment was introduced alternatively before or after braiding by two-dipping-two-rolling method (M1 group and M2 group). The antibacterial activity and durability against Staphylococcus aureus and Escherichia coli were tested. Drug release profiles were measured in phosphate buffer with different pH values, and release kinetics model was built to analyze the sustained drug release mechanism between the interface of biomaterials and the in vitro aqueous environment. Knot-pull tensile strength, thread-to-thread friction, and bending stiffness were determined to evaluate physical and handling properties of sutures. All coated sutures showed continuous antibacterial efficacy and slow drug release features for more than 5 days. Besides, treated sutures fulfilled U.S. Pharmacopoeia required knot-pull tensile strength. The thread-to-thread friction and bending stiffness for the M1 group changed slightly when compared with those of uncoated ones. However, physical and handling characteristics of the M2 group tend to approach those of monofilament ones. The novel suture showed acceptable in vitro cytotoxicity according to ISO 10993-5. Generally speaking, all coated sutures show potential in acting as antibacterial suture materials, and M1 group is proved to have a higher prospect for clinical applications.
Mechanical model of suture joints with fibrous connective layer
NASA Astrophysics Data System (ADS)
Miroshnichenko, Kateryna; Liu, Lei; Tsukrov, Igor; Li, Yaning
2018-02-01
A composite model for suture joints with a connective layer of aligned fibers embedded in soft matrix is proposed. Based on the principle of complementary virtual work, composite cylinder assemblage (CCA) approach and generalized self-consistent micro-mechanical models, a hierarchical homogenization methodology is developed to systematically quantify the synergistic effects of suture morphology and fiber orientation on the overall mechanical properties of sutures. Suture joints with regular triangular wave-form serve as an example material system to apply this methodology. Both theoretical and finite element mechanical models are developed and compared to evaluate the overall normal stiffness of sutures as a function of wavy morphology of sutures, fiber orientation, fiber volume fraction, and the mechanical properties of fibers and matrix in the interfacial layer. It is found that generally due to the anisotropy-induced coupling effects between tensile and shear deformation, the effective normal stiffness of sutures is highly dependent on the fiber orientation in the connective layer. Also, the effective shear modulus of the connective layer and the stiffness ratio between the fiber and matrix significantly influence the effects of fiber orientation. In addition, optimal fiber orientations are found to maximize the stiffness of suture joints.
da Rosa, Fernando William Figueiredo; Pohl, Pedro Henrique Isoldi; Mader, Ana Maria Amaral Antônio; de Paiva, Carla Peluso; dos Santos, Aline Amaro; Bianco, Bianca; Rodrigues, Luciano Miller Reis
2015-01-01
ABSTRACT Objective To evaluate inflammatory reaction, fibrosis and neovascularization in dural repairs in Wistar rats using four techniques: simple suture, bovine collagen membrane, silicon mesh and silicon mesh with suture. Methods Thirty Wistar rats were randomized in five groups: the first was the control group, submitted to dural tear only. The others underwent durotomy and simple suture, bovine collagen membrane, silicon mesh and silicon mesh with suture. Animals were euthanized and the spine was submitted to histological evaluation with a score system (ranging from zero to 3) for inflammation, neovascularization and fibrosis. Results Fibrosis was significantly different between simple suture and silicon mesh (p=0.005) and between simple suture and mesh with suture (p=0.015), showing that fibrosis is more intense when a foreign body is used in the repair. Bovine membrane was significantly different from mesh plus suture (p=0.011) regarding vascularization. Inflammation was significantly different between simple suture and bovine collagen membrane. Conclusion Silicon mesh, compared to other commercial products available, is a possible alternative for dural repair. More studies are necessary to confirm these findings. PMID:26761555
Real-time endoscopic image orientation correction system using an accelerometer and gyrosensor.
Lee, Hyung-Chul; Jung, Chul-Woo; Kim, Hee Chan
2017-01-01
The discrepancy between spatial orientations of an endoscopic image and a physician's working environment can make it difficult to interpret endoscopic images. In this study, we developed and evaluated a device that corrects the endoscopic image orientation using an accelerometer and gyrosensor. The acceleration of gravity and angular velocity were retrieved from the accelerometer and gyrosensor attached to the handle of the endoscope. The rotational angle of the endoscope handle was calculated using a Kalman filter with transmission delay compensation. Technical evaluation of the orientation correction system was performed using a camera by comparing the optical rotational angle from the captured image with the rotational angle calculated from the sensor outputs. For the clinical utility test, fifteen anesthesiology residents performed a video endoscopic examination of an airway model with and without using the orientation correction system. The participants reported numbers written on papers placed at the left main, right main, and right upper bronchi of the airway model. The correctness and the total time it took participants to report the numbers were recorded. During the technical evaluation, errors in the calculated rotational angle were less than 5 degrees. In the clinical utility test, there was a significant time reduction when using the orientation correction system compared with not using the system (median, 52 vs. 76 seconds; P = .012). In this study, we developed a real-time endoscopic image orientation correction system, which significantly improved physician performance during a video endoscopic exam.
Laparoscopic primary repair and isoperistaltic endoluminal drain for Boerhaave's Syndrome.
Prete, Francesco; Pezzolla, Angela; Nitti, Paolo; Prete, Fernando
2015-01-01
Spontaneous oesophageal rupture, also known as Boerhaave syndrome (BS), is a rare and potentially lethal pathological condition. BS recognition is difficult, while rapidity of diagnosis, along with extension of the lesion, affects type and outcome of treatment. BS was classically treated by thoracotomy, but laparoscopic (LS), thoracoscopic (TS) surgery, and nonsurgical procedures as endoscopic stent positioning or use of glues have been described. Still, there is no model treatment, and selection of the most appropriate therapeutic procedure is complex in the absence of standardised criteria. We successfully managed a patient affected with BS by LS approach and present our experience along with a review of treatment options so far described. Our treatment integrated positioning of an oesophageal isoperistaltic endoluminal drain (IED), that we routinely use in oesophageal sutures at risk of leakage, and of which there is no previous report in the setting of BS. A 68 year old man presented to our attention with true BS, suspected on chest-abdominal CT scan and confirmed by upper GI contrast swallow test, showing leakage of hydro-soluble contrast from the lower third of the oesophagus. Of note, pleural cavities appeared intact. We performed an urgent laparoscopy 12 hours after the onset of symptoms. Laparoscopic toilet of the inferior mediastinum and dual layer oesophageal repair with pedicled omental flap were complemented by positioning of IED, feeding jejunostomy and two tubular drains. The patient had a slow but consistent recovery where IED played as a means of oesophageal suture protection, until he could be discharged home. We think that, when integrity of the pleura is documented, LS should be priority choice to avoid contamination of the pleural cavities. We have to consider every type of oesophageal repair in BS at risk of failure, and every means of protection of the suture is opportune. In our patient the oesophageal suture, covered with a flap of omentum isolated on a pedicle, has also been protected from excessive oesophageal endoluminal pressures by means of a multi-fenestrated two way endooesophageal drain (IED, two way tube type Salem). Oesophageal drain has the finality of relieving tension and monitoring the healing of the oesophageal repair.
Design of illumination system in ring field capsule endoscope
NASA Astrophysics Data System (ADS)
Jeng, Wei-De; Mang, Ou-Yang; Chen, Yu-Ta; Wu, Ying-Yi
2011-03-01
This paper is researching about the illumination system in ring field capsule endoscope. It is difficult to obtain the uniform illumination on the observed object because the light intensity of LED will be changed along its angular displacement and same as luminous intensity distribution curve. So we use the optical design software which is Advanced Systems Analysis Program (ASAP) to build a photometric model for the optimal design of LED illumination system in ring field capsule endoscope. In this paper, the optimal design of illumination uniformity in the ring field capsule endoscope is from origin 0.128 up to optimum 0.603 and it would advance the image quality of ring field capsule endoscope greatly.
Yin, Xinghong; Hu, Wei; Zhang, Xinhai; Sun, Min
2014-10-01
To explore curative effect with pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap to repair nasal septal perforation. Dissecting mucoperichondrium and mucoperioseptum around the perforation and taking dowm and out xia-ward to the floor of nasal cavity to make a inferior extremity pedicle flap. Then,the flap was tumbled and sutured onto raw surface of contralateral side through perforation. Reapplicating autoallergic temporal musculofascial flap to repair another side perforation. Repairing perforation Sin twelve cases were sucessfully healed in endoscope. The pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap is easy to acquire and no rejection. The flap has good blood supplying, high survival rate and provides adequate transplantating materail to repair comparatively large perforation.
Broad ligament hernia successfully repaired by single-incision laparoscopy: A case report.
Takeyama, Hiroshi; Kogita, Yuya; Nishigaki, Takahiko; Yamashita, Masafumi; Aikawa, Eriko; Hoshi, Minako; Taniguchi, Hirokazu; Maruyama, Yasuki; Nakajima, Kazuhiro; Yamamoto, Yoshimitsu; Adachi, Kazushige; Yamamoto, Hitoshi; Ikeda, Kimimasa; Kurokawa, Eiji
2017-11-08
A 52-year-old woman with a history of two parturitions presented with lower abdominal pain. Multi-detector CT of the abdomen showed discontinuity of the sigmoid colon near the broad ligament on the left side. We assigned a provisional diagnosis of an internal hernia progressing through a defect in the broad ligament. SILS revealed a total broad ligament defect on the left side but no signs of ischemic, necrotic bowel. We successfully repaired the broad ligament defect with suturing. At the 2-month follow-up, the patient remained well with no signs of recurrence. This case appears to be the first report of a broad ligament hernia successfully diagnosed and repaired by SILS. © 2017 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
Automation of a suturing device for minimally invasive surgery.
Göpel, Tobias; Härtl, Felix; Schneider, Armin; Buss, Martin; Feussner, Hubertus
2011-07-01
In minimally invasive surgery, hand suturing is categorized as a challenge in technique as well as in its duration. This calls for an easily manageable tool, permitting an all-purpose, cost-efficient, and secure viscerosynthesis. Such a tool for this field already exists: the Autosuture EndoStitch(®). In a series of studies the potential for the EndoStitch to accelerate suturing has been proven. However, its ergonomics still limits its applicability. The goal of this study was twofold: propose an optimized and partially automated EndoStitch and compare the conventional EndoStitch to the optimized and partially automated EndoStitch with respect to the speed and precision of suturing. Based on the EndoStitch, a partially automated suturing tool has been developed. With the aid of a DC motor, triggered by a button, one can suture by one-fingered handling. Using the partially automated suturing manipulator, 20 surgeons with different levels of laparoscopic experience successfully completed a continuous suture with 10 stitches using the conventional and the partially automated suture manipulator. Before that, each participant was given 1 min of instruction and 1 min for training. Absolute suturing time and stitch accuracy were measured. The quality of the automated EndoStitch with respect to manipulation was tested with the aid of a standardized questionnaire. To compare the two instruments, t tests were used for suturing accuracy and time. Of the 20 surgeons with laparoscopic experience (fewer than 5 laparoscopic interventions, n=9; fewer than 20 laparoscopic interventions, n=7; more than 20 laparoscopic interventions, n=4), there was no significant difference between the two tested systems with respect to stitching accuracy. However, the suturing time was significantly shorter with the Autostitch (P=0.01). The difference in accuracy and speed was not statistically significant considering the laparoscopic experience of the surgeons. The weight and size of the Autostitch have been criticized as well as its cable. However, the comfortable handhold, automatic needle change, and ergonomic manipulation have been rated positive. Partially automated suturing in minimally invasive surgery offers advantages with respect to the speed of operation and ergonomics. Ongoing work in this field has to concentrate on minimization, implementation in robotic systems, and development of new operation methods (NOTES).
Cranial suture complexity in caviomorph rodents (Rodentia; Ctenohystrica).
Buezas, Guido; Becerra, Federico; Vassallo, Aldo
2017-08-01
Due to their flexibility, sutures are regions that experience greater strains than the surrounding rigid cranial bones. Cranial sutures differ in their degree of interdigitation or complexity. There is evidence indicating that a more convoluted suture better enables the absorption of high stresses coming from dynamic masticatory forces, and other functions. The Order Rodentia is an interesting clade to study this because of its taxa with diverse chewing modes. Due to repeated loading resulting from gnawing and grinding, energy absorption by the sutures might be a crucial factor in these mammals. Species within the infraorder Caviomorpha were chosen as a case study because of their ecomorphological and dietary diversity. This study compared five sutures from the rostrum and cranial vault across seven caviomorph families, and assessed their complexity by means of the relative length and fractal dimension. Across these rodents, cranial sutures are morphologically quite diverse. We found that the sutures connecting the rostrum with the vault were relatively more interdigitated than those in the cranial vault itself, especially premaxillofrontal sutures. Suture interdigitation was higher in species that display chisel-tooth digging and burrowing behaviors, especially in the families Ctenomyidae and Octodontidae, than those in families Dasyproctidae and Cuniculidae, which have more gracile masticatory systems. The reconstruction of the ancestral character state, on family and species phylogeny, points toward low suture interdigitation (i.e., low length ratio) as a likely ancestral state for interfrontal, premaxillofrontal and maxillofrontal sutures. Interspecific differences in suture morphology shown here might represent adaptations to different mechanical demands (i.e., soft vs. tough foods) or behaviors (e.g., chisel-tooth digging), which evolved in close association with the diverse environments occupied by caviomorph rodents. © 2017 Wiley Periodicals, Inc.
Cho, Byung-Ki; Kim, Yong-Min; Park, Kyoung-Jin; Park, Ji-Kang; Kim, Do-Kyoon
2015-02-01
There are various ligament reattachment techniques for the modified Brostrom procedure. There have been few comparative studies on recently developed techniques. This prospective study was performed to compare the functional outcomes of 2 different ligament reattachment techniques using suture anchors. We furthermore evaluated the cost-effectiveness of the suture bridge technique. Forty-five amateur athletes under 30 years of age were followed for more than 2 years. Twenty-four procedures with the suture anchor technique and 21 procedures with the suture bridge technique were performed by one surgeon. The functional evaluation consisted of the American Orthopaedic Foot & Ankle Society (AOFAS) score, Foot and Ankle Outcome Score (FAOS), Karlsson score, Sefton grading system, and the period to return to various forms of exercise (jogging, spurt running, jumping, one leg standing for >1 minute, walking on uneven ground, and going down stairs). Measurement of talar tilt angle and anterior talar translation was obtained from stress radiographs to evaluate mechanical stability. There were no significant differences on AOFAS score, FAOS, Karlsson score, Sefton grade, and stress radiographs. There were no significant differences on the return to exercises, except for jumping. As the most common complication, there were 3 cases of skin irritation by suture materials in the suture anchor group and 2 cases of intraoperative breakage of the suture anchor in suture bridge group. Both ligament reattachment techniques using suture anchors showed similar functional outcomes. Considering the additional medical expenses incurred by more suture anchors, the modified Brostrom procedure using the suture bridge technique had low cost-effectiveness. Proper indication and clinical usefulness of suture bridge technique for chronic ankle instability will be addressed in further studies. Level II, prospective comparative study. © The Author(s) 2014.
Chen, Cheng-Che; Yang, Cheng-Kuang; Hung, Siu-Wan; Wang, John; Ou, Yen-Chuan
2015-10-01
The use of a da Vinci robotic system may improve the outcome of urological surgery. This study reports 6 years of experience with vesicourethral anastomosis (VUA) following robot-assisted laparoscopic radical prostatectomy (RALP) performed in Taichung Veterans General Hospital, Taichung, Taiwan. A total of 350 patients who underwent RALP by a single surgeon were reviewed. We followed Dr Patel's RALP procedure with minor modifications. VUA was checked with 120 mL and 200 mL saline in sequence. The urinary bladder was then pressed with endoscopic instruments. If a VUA leak was detected, it was sutured immediately. An 18-French silicon Foley's catheter was inserted and removed 7-14 days after RALP. Preoperative characteristics and perioperative complications were assessed. Overall, 332 (94.85%) patients were without any leakage in the first step of the challenge, eight of whom had leakage in the second step. After repair, all were free from leakage. The other 18 patients had leakage in the first step of the challenge (5.14%). After repair, 12 patients were without leakage in the second step. However, one patient had urine leakage postoperatively. The other six patients had leakage in the second step. After repair, two patients were free from leakage, but the remaining four suffered from persistent minor urine leakage postoperatively. The urine leakage rate after RALP was 1.43% (5/350). The potential urine leakage after bladder challenge and endoscopic instruments pressing could be minimized to 0.29% (1/346). VUA leakage after RALP is rare. Intraoperative VUA challenge is simple and feasible compared to postoperative retrograde cystography. Copyright © 2014. Published by Elsevier B.V.
Ishii, Yudo; Tahara, Shigeyuki; Teramoto, Akira; Morita, Akio
2014-01-01
In recent years, resections of midline skull base tumors have been conducted using endoscopic endonasal skull base (EESB) approaches. Nevertheless, many surgeons reported that cerebrospinal fluid (CSF) leakage is still a major complication of these approaches. Here, we report the results of our 42 EESB surgeries and discuss the advantages and limits of this approach for resecting various types of tumors, and also report our technique to overcome CSF leakage. All 42 cases involved midline skull base tumors resected using the EESB technique. Dural incisions were closed using nasoseptal flaps and fascia patch inlay sutures. Total removal of the tumor was accomplished in seven pituitary adenomas (33.3%), five craniopharyngiomas (62.5%), five tuberculum sellae meningiomas (83.3%), three clival chordomas (100%), and one suprasellar ependymoma. Residual regions included the cavernous sinus, the outside of the intracranial part of the internal carotid artery, the lower lateral part of the posterior clivus, and the posterior pituitary stalk. Overall incidence of CSF leakage was 7.1%. Even though the versatility of the approach is limited, EESB surgery has many advantages compared to the transcranial approach for managing mid-line skull base lesions. To avoid CSF leakage, surgeons should have skills and techniques for complete closure, including use of the nasoseptal flap and fascia patch inlay techniques.
Does vascular stapling improve compliance of vascular anastomoses?
Stansby, G; Knez, P; Berwanger, C S; Nelson, K; Reichert, V; Schmitz-Rixen, T
2001-01-01
Elastic properties of vessel walls are altered by vascular anastomoses. Such alterations may lead to neointimal hyperplasia, which is a common cause of reocclusion following vascular surgery. The severity of paraanastomotic hypercompliant zones and anastomotic compliance drop depend on suturing material and on elastic properties of the anastomotic vessel segments. This study compares paraanastomotic hypercompliance and anastomotic compliance drop when using a new vascular closure system (VCS) and a conventional, continuous suture line in the preparation of end-to-end anastomoses. Compliance of artery-artery, vein-artery, and polytetrafluoroethylene-artery anastomoses was measured in an artificial circulation system at mean pressures of 60, 90, and 120 mm Hg, comparing conventional suturing and the VCS. When using the VCS for vein-artery anastomoses, significantly less postanastomotic hypercompliance was achieved at mean pressures of 60 mm Hg (14.2 +/-3.8% above remote postanastomotic area), compared to suture (55.1 +/-14.8%, p<0.05). At 90 mm Hg, respective values were 11.0 +/-2.3% for VCS and 54.7 +/-10.1% for suture, p<0.01. At 120 mm Hg, in polytetrafluoroethylene-artery anastomoses, the anastomotic compliance drop was significantly less when using the continuous suture line (93.9 +/-1.1% below remote postanastomotic compliance), compared to VCS (97.2 +/-0.2%, p<0.05). Compared to conventional suturing, use of the VCS reduced postanastomotic hypercompliance in vein-artery anastomoses.
Clinical study using novel endoscopic system for measuring size of gastrointestinal lesion
Oka, Kiyoshi; Seki, Takeshi; Akatsu, Tomohiro; Wakabayashi, Takao; Inui, Kazuo; Yoshino, Junji
2014-01-01
AIM: To verify the performance of a lesion size measurement system through a clinical study. METHODS: Our proposed system, which consists of a conventional endoscope, an optical device, an optical probe, and a personal computer, generates a grid scale to measure the lesion size from an endoscopic image. The width of the grid scale is constantly adjusted according to the distance between the tip of the endoscope and lesion because the lesion size on an endoscopic image changes according to the distance. The shape of the grid scale was corrected to match the distortion of the endoscopic image. The distance was calculated using the amount of laser light reflected from the lesion through an optical probe inserted into the instrument channel of the endoscope. The endoscopist can thus measure the lesion size without contact by comparing the lesion with the size of the grid scale on the endoscopic image. (1) A basic test was performed to verify the relationship between the measurement error eM and the tilt angle of the endoscope; and (2) The sizes of three colon polyps were measured using our system during endoscopy. These sizes were immediately measured by scale after their removal. RESULTS: There was no error at α = 0°. In addition, the values of eM (mean ± SD) were 0.24 ± 0.11 mm (α = 10°), 0.90 ± 0.58 mm (α = 20°) and 2.31 ± 1.41 mm (α = 30°). According to these results, our system has been confirmed to measure accurately when the tilt angle is less than 20°. The measurement error was approximately 1 mm in the clinical study. Therefore, it was concluded that our proposed measurement system was also effective in clinical examinations. CONCLUSION: By combining simple optical equipment with a conventional endoscope, a quick and accurate system for measuring lesion size was established. PMID:24744595
Endoscopic control of enterocutaneous fistula by dual intussuscepting stent technique.
Melich, George; Pai, Ajit; Balachandran, Banujan; Marecik, Slawomir J; Prasad, Leela M; Park, John J
2016-09-01
Large high-output enterocutaneous fistulas pose great difficulties, especially in the setting of recent surgery and compromised skin integrity. This video demonstrates a new technique of endoscopic control of enterocutaneous fistula by using two covered overlapping stents. In brief, the two stents are each inserted endoscopically, one proximal, and the other distal to the fistula with 2 cm of each stent protruding cutaneously. Following this, the proximal stent is crimped and intussuscepted into the distal stent with an adequate overlap. A prolene suture is passed through the anterior wall of both stents to prevent migration. The two stents used were evolution esophageal stents-10 cm long, fully covered, double-flared with non-flared and flared diameters being 20 and 25 mm, respectively (product number EVO-FC-20-25-10-E, Cook Medical, Bloomington, IN, USA). The patient featured in this video developed a high-output enterocutaneous fistula proximal to a loop ileostomy, which was created following a small bowel leak after a curative surgery for bladder cancer. Using the technique featured in this video (schematic depicted in Fig. 1), the patient was nutritionally optimized with oral feeds from albumin of 0.9-3.4 g/dl within 2 months despite prior failure to achieve nutrition optimization and adequate skin protection with combination of oral and/or parenteral nutrition. Three months after stenting, following nutritional optimization and improvement of skin coverage, definitive procedure consisted of uncomplicated fistula resection with primary stapled side-to-side functional end-to-end anastomosis. The stents were not completely incorporated into the mucosa and were rather easily pulled through the residual fistula opening just prior to the surgery. Only minimal fibrosis was noted and less than 20 cm of involved small bowel needed to be resected. Had the fistula have closed completely, the options would have included (1) proceeding to bowel resection with removal of the stents regardless of closure, or (2) cutting the securing prolene stitch and observation. Considering the placement of the stents in mid-small bowel, their endoscopic retrieval would have been difficult unless they were to migrate into the colon. Although a prior attempt at managing an enterocutaneous fistula with a stent deployed through a colostomy site was previously reported [1], there is no published account of bridging an enterocutaneous fistula with overlapping endoscopic stents through the fistula itself. This video serves as a proof of concept for temporizing enterocutaneous fistulas with endoscopic stenting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arezzo, Alberto, E-mail: alberto.arezzo@unito.it; Arolfo, Simone; Allaix, Marco Ettore
Purpose: This study was undertaken to assess the short-term outcomes of neoadjuvant short-course radiation therapy (SCRT) followed by transanal endoscopic microsurgery (TEM) for T1-T2 N0 extraperitoneal rectal cancer. Recent studies suggest that neoadjuvant radiation therapy followed by TEM is safe and has results similar to those with abdominal rectal resection for the treatment of extraperitoneal early rectal cancer. Methods and Materials: We planned a prospective pilot study including 25 consecutive patients with extraperitoneal T1-T2 N0 M0 rectal adenocarcinoma undergoing SCRT followed by TEM 4 to 10 weeks later (SCRT-TEM). Safety, efficacy, and acceptability of this treatment modality were compared with historicalmore » groups of patients with similar rectal cancer stage and treated with long-course radiation therapy (LCRT) followed by TEM (LCRT-TEM), TEM alone, or laparoscopic rectal resection with total mesorectal excision (TME) at our institution. Results: The study was interrupted after 14 patients underwent SCRT of 25 Gy in 5 fractions followed by TEM. Median time between SCRT and TEM was 7 weeks (range: 4-10 weeks). Although no preoperative complications occurred, rectal suture dehiscence was observed in 7 patients (50%) at 4 weeks follow-up, associated with an enterocutaneous fistula in the sacral area in 2 cases. One patient required a colostomy. Quality of life at 1-month follow-up, according to European Organization for Research and Treatment of Cancer QLQ-C30 survey score, was significantly worse in SCRT-TEM patients than in LCRT-TEM patients (P=.0277) or TEM patients (P=.0004), whereas no differences were observed with TME patients (P=.604). At a median follow-up of 10 months (range: 6-26 months), we observed 1 (7%) local recurrence at 6 months that was treated with abdominoperineal resection. Conclusions: SCRT followed by TEM for T1-T2 N0 rectal cancer is burdened by a high rate of painful dehiscence of the suture line and enterocutaneous fistula, compared to TEM alone and TEM following LCRT, which forced us to stop the study.« less
[Robot-assisted atrial septal defect closure in adults: first experience in Russia].
Arkhipov, A N; Bogachev-Prokofiev, A V; Zubritskiy, A V; Khapaev, T S; Gorbatykh, Yu N; Pavlushin, P M; Karaskov, A M
To analyze immediate results of minimally invasive robot-assisted atrial septal defect (ASD) closure in adults. For the period from March 2012 to November 2016 sixty patients with contraindications to endovascular procedure have undergone robot-assisted atrial septal defect closure at Meshalkin Siberian Federal Biomedical Research Center. Mean age was 34.5±11.3 years, body mass index - 24.6±4.0 kg/m 2 . 48 (80%) patients had NYHA class II before surgery. In 37 (61.7%) patients isolated ASD with deficiency or absence of one edge was diagnosed, isolated ASD with primary septum aneurysm - in 16 (26.7%) cases, 7 (11.6%) patients had reticulate ASD. 5 (8.3%) patients had concomitant tricuspid valve insufficiency required surgical repair (suture annuloplasty). All operations were performed under cardiopulmonary bypass with peripheral cannulation. Right-sided anterolateral mini-thoracotomy was used in the first 43 patients. Following 17 patients underwent completely endoscopic procedure. Depending on the shape, size and anatomical features of the defect we performed suturing (14 patients, 23.3%) or repair with xenopericardial patch (46%, 76.6%). Mean CPB and aortic cross-clamping time was 89.1±28.7 and 24.8±9.5 min, respectively. Postoperative variables: mechanical ventilation 3.3±1.5 hours, ICU-stay - 18.2±3.7 hours, postoperative hospital-stay - 13.4±5.7 days. There were no mortality and any life-threatening intra- and postoperative complications. Cases of conversion to thoraco-/sternotomy and postoperative bleeding followed by redo surgery were also absent. 23 patients were followed-up within 1 year, 6 patients - within 2 years, 3 patients - within 3 years. All patients were in NYHA class I-II with 100% freedom from ASD recanalization and redo surgery. According to echocardiography data there were decreased right heart, pulmonary artery pressure and preserved left ventricular function in early postoperative period and 1 year after surgery. In view of favorable course of postoperative period, no significant specific complications and encouraging immediate results we can talk about endoscopic robot-assisted ASD closure in adults as a safe and effective alternative to surgical treatment.
[Review of the active locomotion system for capsule endoscope].
Zhao, Dechun; Guo, Yijun; Peng, Chenglin
2010-02-01
This review summarized the progress of researches on the active locomotion system for capsule endoscope, analyzed the moving and controlling principles in different locomotion systems, and compared their merits and shortcomings. Owing to the complexity of human intestines and the limits to the size and consumption of locomotion system from the capsule endoscope, there is not yet one kind of active locomotion system currently used in clinical practice. The locomotive system driven by an outer rotational magnetic field could improve the commercial endoscope capsule, while its magnetic field controlling moving is complex. Active locomotion system driven by shape memory alloys will be the orientated development and the point of research in the future.
Chouillard, Elie; Chahine, Elias; Schoucair, Naim; Younan, Antoine; Jarallah, Mohammad Al; Fajardy, Alain; Vitte, René-Louis; Biagini, Jean
2014-06-01
Sleeve gastrectomy (SG) is currently the most common bariatric procedure in France. It achieves both adequate excess weight loss and significant reduction of comorbidities. However, leak is still the most common complication after SG. Nevertheless, its risk of occurrence is <3% in specialized centers. Its management is difficult, long, and challenging. Although the procedure is commonly endoscopic and nonoperative, the management of post-SG fistulas could sometimes be surgical, including peritoneal lavage, abscess drainage, disrupted staple line suturing, resleeve, gastric bypass, or total gastrectomy. Roux-en-Y fistulojejunostomy (RYFJ) has been described as a salvage option. In this study, we report the early results of RYFJ for post-SG fistula, emphasizing indications, operative technique, and short-term outcome. Between January 2007 and December 2012, we treated 62 patients with post-SG fistula. Before surgery, intra-abdominal or thoracic abscesses or collections were either excluded or treated by computed tomographic scan-guided drainage or even surgery. Endoscopic stenting was then attempted. After optimization of the nutritional status in case of failure of endoscopic measures, some of the patients underwent RYFJ. Between January 2007 and December 2012, a total of 21 patients (16 women and 5 men) had RYFJ for post-SG fistula. Mean age was 47 years (range, 22-59 years). Procedures were performed laparoscopically in all but 3 cases. The rate of secondary conversion to laparotomy was 11.1%. The was no mortality. The postoperative morbidity rate was less than 5%. The rate of fistula control was eventually 100%. RYFJ is a safe and feasible salvage procedure for the treatment of patients with post-SG fistula. Longer outcome analysis is, however, needed especially regarding the physiological and metabolic behavior of the procedure.
A 3D photographic capsule endoscope system with full field of view
NASA Astrophysics Data System (ADS)
Ou-Yang, Mang; Jeng, Wei-De; Lai, Chien-Cheng; Kung, Yi-Chinn; Tao, Kuan-Heng
2013-09-01
Current capsule endoscope uses one camera to capture the surface image in the intestine. It can only observe the abnormal point, but cannot know the exact information of this abnormal point. Using two cameras can generate 3D images, but the visual plane changes while capsule endoscope rotates. It causes that two cameras can't capture the images information completely. To solve this question, this research provides a new kind of capsule endoscope to capture 3D images, which is 'A 3D photographic capsule endoscope system'. The system uses three cameras to capture images in real time. The advantage is increasing the viewing range up to 2.99 times respect to the two camera system. The system can accompany 3D monitor provides the exact information of symptom points, helping doctors diagnose the disease.
Hashizume, M; Shimada, M; Tomikawa, M; Ikeda, Y; Takahashi, I; Abe, R; Koga, F; Gotoh, N; Konishi, K; Maehara, S; Sugimachi, K
2002-08-01
We performed a variety of complete total endoscopic general surgical procedures, including colon resection, distal gastrectomy, and splenectomy, successfully with the assistance of the da Vinci computer-enhanced surgical system. The robotic system allowed us to manipulate the endoscopic instruments as effectively as during open surgery. It enhanced visualization of both the operative field and precision of the necessary techniques, as well as being less stressful for the endoscopic operating team. This technological innovation can therefore help surgeons overcome many of the difficulties associated with the endoscopic approach and thus has the potential to enable more precise, safer, and more minimally invasive surgery in the future.
Endoscopic optical coherence tomography: technologies and clinical applications [Invited
Gora, Michalina J.; Suter, Melissa J.; Tearney, Guillermo J.; Li, Xingde
2017-01-01
In this paper, we review the current state of technology development and clinical applications of endoscopic optical coherence tomography (OCT). Key design and engineering considerations are discussed for most OCT endoscopes, including side-viewing and forward-viewing probes, along with different scanning mechanisms (proximal-scanning versus distal-scanning). Multi-modal endoscopes that integrate OCT with other imaging modalities are also discussed. The review of clinical applications of endoscopic OCT focuses heavily on diagnosis of diseases and guidance of interventions. Representative applications in several organ systems are presented, such as in the cardiovascular, digestive, respiratory, and reproductive systems. A brief outlook of the field of endoscopic OCT is also discussed. PMID:28663882
Wang, Weian; Lu, Rong
2013-06-01
To investigate the effect of laryngoscopic surgery combined with nasal endoscopic system for the treatment of vocal cords benign lesions. Fifty-two patients admitted to our department with vocal cords benign lesions (including vocal polyps, vocal nodules, vocal cord cyst) underwent laryngoscopic surgery combined with nasal endoscopic system. All patients were treated successfully once and for all without any significant postoperative complication. The laryngoscopic surgery combined with nasal endoscopic system is a safe, minimally invasive and simple method for the treatment of benign lesions of vocal cords.
[Experience of Fusion image guided system in endonasal endoscopic surgery].
Wen, Jingying; Zhen, Hongtao; Shi, Lili; Cao, Pingping; Cui, Yonghua
2015-08-01
To review endonasal endoscopic surgeries aided by Fusion image guided system, and to explore the application value of Fusion image guided system in endonasal endoscopic surgeries. Retrospective research. Sixty cases of endonasal endoscopic surgeries aided by Fusion image guided system were analysed including chronic rhinosinusitis with polyp (n = 10), fungus sinusitis (n = 5), endoscopic optic nerve decompression (n = 16), inverted papilloma of the paranasal sinus (n = 9), ossifying fibroma of sphenoid bone (n = 1), malignance of the paranasal sinus (n = 9), cerebrospinal fluid leak (n = 5), hemangioma of orbital apex (n = 2) and orbital reconstruction (n = 3). Sixty cases of endonasal endoscopic surgeries completed successfully without any complications. Fusion image guided system can help to identify the ostium of paranasal sinus, lamina papyracea and skull base. Fused CT-CTA images, or fused MR-MRA images can help to localize the optic nerve or internal carotid arteiy . Fused CT-MR images can help to detect the range of the tumor. It spent (7.13 ± 1.358) minutes for image guided system to do preoperative preparation and the surgical navigation accuracy reached less than 1mm after proficient. There was no device localization problem because of block or head set loosed. Fusion image guided system make endonasal endoscopic surgery to be a true microinvasive and exact surgery. It spends less preoperative preparation time, has high surgical navigation accuracy, improves the surgical safety and reduces the surgical complications.
An Anatomic and Biomechanical Comparison of Bankart Repair Configurations.
Judson, Christopher H; Voss, Andreas; Obopilwe, Elifho; Dyrna, Felix; Arciero, Robert A; Shea, Kevin P
2017-11-01
Suture anchor repair for anterior shoulder instability can be performed using a number of different repair techniques, but none has been proven superior in terms of anatomic and biomechanical properties. Purpose/Hypothesis: The purpose was to compare the anatomic footprint coverage and biomechanical characteristics of 4 different Bankart repair techniques: (1) single row with simple sutures, (2) single row with horizontal mattress sutures, (3) double row with sutures, and (4) double row with labral tape. The hypotheses were as follows: (1) double-row techniques would improve the footprint coverage and biomechanical properties compared with single-row techniques, (2) horizontal mattress sutures would increase the footprint coverage compared with simple sutures, and (3) repair techniques with labral tape and sutures would not show different biomechanical properties. Controlled laboratory study. Twenty-four fresh-frozen cadaveric specimens were dissected. The native labrum was removed and the footprint marked and measured. Repair for each of the 4 groups was performed, and the uncovered footprint was measured using a 3-dimensional digitizer. The strength of the repair sites was assessed using a servohydraulic testing machine and a digital video system to record load to failure, cyclic displacement, and stiffness. The double-row repair techniques with sutures and labral tape covered 73.4% and 77.0% of the footprint, respectively. These percentages were significantly higher than the footprint coverage achieved by single-row repair techniques using simple sutures (38.1%) and horizontal mattress sutures (32.8%) ( P < .001). The footprint coverage of the simple suture and horizontal mattress suture groups was not significantly different ( P = .44). There were no significant differences in load to failure, cyclic displacement, or stiffness between the single-row and double-row groups or between the simple suture and horizontal mattress suture techniques. Likewise, there was no difference in the biomechanical properties of the double-row repair techniques with sutures versus labral tape. Double-row repair techniques provided better coverage of the native footprint of the labrum but did not provide superior biomechanical properties compared with single-row repair techniques. There was no difference in footprint coverage or biomechanical strength between the simple suture and horizontal mattress suture repair techniques. Although the double-row repair techniques had no difference in initial strength, they may improve healing in high-risk patients by improving the footprint coverage.
Basics of robotics and manipulators in endoscopic surgery.
Rininsland, H H
1993-06-01
The experience with sophisticated remote handling systems for nuclear operations in inaccessible rooms can to a large extent be transferred to the development of robotics and telemanipulators for endoscopic surgery. A telemanipulator system is described consisting of manipulator, endeffector and tools, 3-D video-endoscope, sensors, intelligent control system, modeling and graphic simulation and man-machine interfaces as the main components or subsystems. Such a telemanipulator seems to be medically worthwhile and technically feasible, but needs a lot of effort from different scientific disciplines to become a safe and reliable instrument for future endoscopic surgery.
Park, In-Seop; Kim, Sung-Jae
2006-08-01
We introduce a suture technique to repair a peripheral tear near the posterior tibial attachment of the posterior horn. A suture hook was inserted through the posteromedial portal, and the peripheral capsular rim was penetrated from superior to inferior by the sharp hook. Both relay limbs were brought out through the posteromedial portal. The outer limb of the superior peripheral capsular rim was identified with a hemostat. An 18-gauge spinal needle loaded with a No. 0 polydioxanone suture (PDS) was introduced into the joint from the anteromedial portal; it was passed through the joint space until it penetrated the inner torn meniscus. The PDS suture loaded within the needle was pushed into the joint and picked up through the posteromedial portal. The needle was pulled out of the torn meniscus and readvanced over it while the suture was kept loaded. The other limb of the suture from the tip of the spinal needle was retrieved through the posteromedial portal. The initial PDS suture limb was hooked to the shuttle-relay system; it then was passed through the inner torn meniscus and the peripheral capsular rim. The suture limb exiting from the peripheral capsular rim was used as a post and was joined to the other suture limb to form a sliding knot.
Conjugation of fiber-coupled wide-band light sources and acousto-optical spectral elements
NASA Astrophysics Data System (ADS)
Machikhin, Alexander; Batshev, Vladislav; Polschikova, Olga; Khokhlov, Demid; Pozhar, Vitold; Gorevoy, Alexey
2017-12-01
Endoscopic instrumentation is widely used for diagnostics and surgery. The imaging systems, which provide the hyperspectral information of the tissues accessible by endoscopes, are particularly interesting and promising for in vivo photoluminescence diagnostics and therapy of tumour and inflammatory diseases. To add the spectral imaging feature to standard video endoscopes, we propose to implement acousto-optical (AO) filtration of wide-band illumination of incandescent-lamp-based light sources. To collect maximum light and direct it to the fiber-optic light guide inside the endoscopic probe, we have developed and tested the optical system for coupling the light source, the acousto-optical tunable filter (AOTF) and the light guide. The system is compact and compatible with the standard endoscopic components.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
... Administration (FDA) is classifying the endovascular suturing system into class II (special controls). The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance..., or FDA issues an order finding the device to be substantially equivalent, in accordance with section...
Towards automated visual flexible endoscope navigation.
van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J
2013-10-01
The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.
[Calculation of optic system of superfine medical endoscopes based on gradient elements].
Díakonov, S Iu; Korolev, A V
1994-01-01
The application of gradient optic elements to rigid endoscopes decreases their diameter to 1.5-2.0 mm. The given mathematical dependences determine aperture and field characteristics, focus and focal segments, resolution of the optic systems based on gradient optics. Parameters of the gradient optic systems for superfine medical endoscopes are characterized and their practical application is shown.
Performance evaluation of stereo endoscopic imaging system incorporating TFT-LCD.
Song, C-G; Park, S-K
2005-01-01
This paper presents a 3D endoscopic video system designed to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. In a comparison of the polarized and electric shutter-type stereo imaging systems, the former was found to be superior in terms of both accuracy and speed for knot-tying and for the loop pass test. The results of our experiments show that the proposed 3D endoscopic system has a sufficiently wide viewing angle and zone for multi-viewing, and that it provides better image quality and more stable optical performance compared with the electric shutter-type.
Laser scanning endoscope for diagnostic medicine
NASA Astrophysics Data System (ADS)
Ouimette, Donald R.; Nudelman, Sol; Spackman, Thomas; Zaccheo, Scott
1990-07-01
A new type of endoscope is being developed which utilizes an optical raster scanning system for imaging through an endoscope. The optical raster scanner utilizes a high speed, multifaceted, rotating polygon mirror system for horizontal deflection, and a slower speed galvanometer driven mirror as the vertical deflection system. When used in combination, the optical raster scanner traces out a raster similar to an electron beam raster used in television systems. This flying spot of light can then be detected by various types of photosensitive detectors to generate a video image of the surface or scene being illuminated by the scanning beam. The optical raster scanner has been coupled to an endoscope. The raster is projected down the endoscope, thereby illuminating the object to be imaged at the distal end of the endoscope. Elemental photodetectors are placed at the distal or proximal end of the endoscope to detect the reflected illumination from the flying spot of light. This time sequenced signal is captured by an image processor for display and processing. This technique offers the possibility for very small diameter endoscopes since illumination channel requirements are eliminated. Using various lasers, very specific spectral selectivity can be achieved to optimum contrast of specific lesions of interest. Using several laser lines, or a white light source, with detectors of specific spectral response, multiple spectrally selected images can be acquired simultaneously. The potential for co-linear therapy delivery while imaging is also possible.
Kim, Myungjoon; Lee, Chiwon; Hong, Nhayoung; Kim, Yoon Jae; Kim, Sungwan
2017-06-24
Although robotic laparoscopic surgery has various benefits when compared with conventional open surgery and minimally invasive surgery, it also has issues to overcome and one of the issues is the discontinuous surgical flow that occurs whenever control is swapped between the endoscope system and the operating robot arm system. This can lead to problems such as collision between surgical instruments, injury to patients, and increased operation time. To achieve continuous surgical operation, a wireless controllable stereo endoscope system is proposed which enables the simultaneous control of the operating robot arm system and the endoscope system. The proposed system consists of two improved novel master interfaces (iNMIs), a four-degrees of freedom (4-DOFs) endoscope control system (ECS), and a simple three-dimensional (3D) endoscope. In order to simultaneously control the proposed system and patient side manipulators of da Vinci research kit (dVRK), the iNMIs are installed to the master tool manipulators of dVRK system. The 4-DOFs ECS consists of four servo motors and employs a two-parallel link structure to provide translational and fulcrum point motion to the simple 3D endoscope. The images acquired by the endoscope undergo stereo calibration and rectification to provide a clear 3D vision to the surgeon as available in clinically used da Vinci surgical robot systems. Tests designed to verify the accuracy, data transfer time, and power consumption of the iNMIs were performed. The workspace was calculated to estimate clinical applicability and a modified peg transfer task was conducted with three novice volunteers. The iNMIs operated for 317 min and moved in accordance with the surgeon's desire with a mean latency of 5 ms. The workspace was calculated to be 20378.3 cm 3 , which exceeds the reference workspace of 549.5 cm 3 . The novice volunteers were able to successfully execute the modified peg transfer task designed to evaluate the proposed system's overall performance. The experimental results verify that the proposed 3D endoscope system enables continuous surgical flow. The workspace is suitable for the performance of numerous types of surgeries. Therefore, the proposed system is expected to provide much higher safety and efficacy for current surgical robot systems.
Analysis of the color rendition of flexible endoscopes
NASA Astrophysics Data System (ADS)
Murphy, Edward M.; Hegarty, Francis J.; McMahon, Barry P.; Boyle, Gerard
2003-03-01
Endoscopes are imaging devices routinely used for the diagnosis of disease within the human digestive tract. Light is transmitted into the body cavity via incoherent fibreoptic bundles and is controlled by a light feedback system. Fibreoptic endoscopes use coherent fibreoptic bundles to provide the clinician with an image. It is also possible to couple fibreoptic endoscopes to a clip-on video camera. Video endoscopes consist of a small CCD camera, which is inserted into gastrointestinal tract, and associated image processor to convert the signal to analogue RGB video signals. Images from both types of endoscope are displayed on standard video monitors. Diagnosis is dependent upon being able to determine changes in the structure and colour of tissues and biological fluids, and therefore is dependent upon the ability of the endoscope to reproduce the colour of these tissues and fluids with fidelity. This study investigates the colour reproduction of flexible optical and video endoscopes. Fibreoptic and video endoscopes alter image colour characteristics in different ways. The colour rendition of fibreoptic endoscopes was assessed by coupling them to a video camera and applying video colorimetric techniques. These techniques were then used on video endoscopes to assess how the colour rendition of video endoscopes compared with that of optical endoscopes. In both cases results were obtained at fixed illumination settings. Video endoscopes were then assessed with varying levels of illumination. Initial results show that at constant luminance endoscopy systems introduce non-linear shifts in colour. Techniques for examining how this colour shift varies with illumination intensity were developed and both methodology and results will be presented. We conclude that more rigorous quality assurance is required to reduce colour error and are developing calibration procedures applicable to medical endoscopes.
Design of an autofocus capsule endoscope system and the corresponding 3D reconstruction algorithm.
Zhang, Wei; Jin, Yi-Tao; Guo, Xin; Su, Jin-Hui; You, Su-Ping
2016-10-01
A traditional capsule endoscope can only take 2D images, and most of the images are not clear enough to be used for diagnosing. A 3D capsule endoscope can help doctors make a quicker and more accurate diagnosis. However, blurred images negatively affect reconstruction accuracy. A compact, autofocus capsule endoscope system is designed in this study. Using a liquid lens, the system can be electronically controlled to autofocus, and without any moving elements. The depth of field of the system is in the 3-100 mm range and its field of view is about 110°. The images captured by this optical system are much clearer than those taken by a traditional capsule endoscope. A 3D reconstruction algorithm is presented to adapt to the zooming function of our proposed system. Simulations and experiments have shown that more feature points can be correctly matched and a higher reconstruction accuracy can be achieved by this strategy.
Comparative study on fixation of central venous catheter by suture versus adhesive device.
Molina-Mazón, C S; Martín-Cerezo, X; Domene-Nieves de la Vega, G; Asensio-Flores, S; Adamuz-Tomás, J
2018-03-27
To assess the efficacy of a central venous catheter adhesive fixation device (CVC) to prevent associated complications. To establish the need for dressing changes, number of days' catheterization and reasons for catheter removal in both study groups. To assess the degree of satisfaction of personnel with the adhesive system. A, randomized, prospective and open pilot study, of parallel groups, with comparative evaluation between CVC fixation with suture and with an adhesive safety system. The study was performed in the Coronary Unit of the Universitari de Bellvitge Hospital, between April and November 2016. The population studied were patients with a CVC. The results were analyzed using SPSS Statistics software. The study was approved by the Clinical Research Ethics Committee. 100 patients (47 adhesive system and 53 suture) were analyzed. Both groups were homogeneous in terms of demographic variables, anticoagulation and days of catheterization. The frequency of complications in the adhesive system group was 21.3%, while in the suture group it was 47.2% (P=.01). The suture group had a higher frequency of local signs of infection (p=.006), catheter displacement (p=.005), and catheter-associated bacteraemia (P=.05). The use of adhesive fixation was associated with a lower requirement for dressing changes due to bleeding (P=.006). Ninety-six point seven percent of the staff recommended using the adhesive safety system. The catheters fixed with adhesive systems had fewer infectious complications and less displacement. Copyright © 2018 Sociedad Española de Enfermería Intensiva y Unidades Coronarias (SEEIUC). Publicado por Elsevier España, S.L.U. All rights reserved.
[The development of endoscope workstation].
Qi, L; Qi, L; Qiou, Q J; Yu, Q L
2001-01-01
This paper introduces an endoscope workstation, which solved the weak points of multimedia endoscope database used by most hospitals. The endoscope workstation was built on pedal-switch and NTFS file system. This paper also Introduces how to make program optimal and quick inputting. The workstation has promoted the efficiency of the doctor's operation.
Endoscope system with plasma flushing and coaxial round jet nozzle for off-pump cardiac surgery.
Horiuchi, Tetsuya; Masamune, Ken; Iwase, Yuki; Ymashita, Hiromasa; Tsukihara, Hiroyuki; Motomura, Noboru; Ohta, Yuji; Dohi, Takeyoshi
2011-07-01
To develop a new endoscope for performing simple surgical tasks inside the blood-filled cardiac atrium/chamber, that is, "off-pump" cardiac surgeries. We developed the endoscope system with plasma flushing and coaxial round jet nozzle. The "plasma flushing" system was invented to observe the interior of the blood-filled heart by displacing blood cells in front of the endoscope tip. However, some areas could not be observed with simple flushing of the liquid because the flushed liquid mixed with blood. Further, a large amount of liquid had to be flushed, which posed a risk of cardiac damage caused by excess volume. Therefore, to safely capture high-resolution images of the interior of the heart, an endoscope with a coaxial round jet nozzle through which plasma is flushed has been developed. And to reduce the volume of flushed liquid, the synchronization system of heartbeat and the endoscope system with plasma flushing has been developed. We conducted an in vivo experiment to determine whether we could observe intracardiac tissues in swine without the use of a heart-lung machine. As a result, we successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. Moreover, we were able to save up to 30% of the flushed liquid by replacing the original system with a synchronization system. And we evaluated the performance of the endoscope with the coaxial round jet nozzle by conducting fluid analysis and an in vitro experiment. We successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. And by replacing an original system to a synchronization system, we were able to save up to 30% of the flushed liquid. As a follow-up study, we plan to create a surgical flexible device for valve disease that can grasp, staple, and repair cardiac valves by endoscopic visualization.
2007-01-01
In this Evaluation, we examine whether the Steris Reliance EPS--a flexible endoscope reprocessing system that was recently introduced to the U.S. market--offers meaningful advantages over "traditional" automated endoscope reprocessors (AERs). Most AERs on the market function similarly to one another. The Reliance EPS, however, includes some unique features that distinguish it from other AERs. For example, it incorporates a "boot" technology for loading the endoscopes into the unit without requiring a lot of endoscope-specific connectors, and it dispenses the germicide used to disinfect the endoscopes from a single-use container. This Evaluation looks at whether the unique features of this model make it a better choice than traditional AERs for reprocessing flexible endoscopes. Our study focuses on whether the Reliance EPS is any more likely to be used correctly-thereby reducing the likelihood that an endoscope will be reprocessed inadequately-and whether the unit possesses any design flaws that could lead to reprocessing failures. We detail the unit's advantages and disadvantages compared with other AERs, and we describe what current users have to say. Our conclusions will help facilities determine whether to select the Reliance EPS.
Fischer, Andreas; Bausch, Dirk; Richter-Schrag, Hans-Juergen
2013-02-01
The use of self-expandable stents to treat postoperative leaks and fistula in the upper gastrointestinal (GI) tract is an established treatment for leaks of the upper GI tract. However, lumen-to-stent size discrepancies (i.e., after sleeve gastrectomy or esophageal resection) may lead to insufficient sealing of the leaks requiring further surgical intervention. This is mainly due to the relatively small diameter (≤30 mm) of commonly used commercial stents. To overcome this problem, we developed a novel partially covered stent with a shaft diameter of 36 mm and a flare diameter of 40 mm. From September 2008 to September 2010, 11 consecutive patients with postoperative leaks were treated with the novel large diameter stent (gastrectomy, n = 5; sleeve gastrectomy, n = 2; fundoplication after esophageal perforation, n = 2; Roux-en-Y gastric bypass, n = 1; esophageal resection, n = 1). Treatment with commercially available stents (shaft/flare: 23/28 mm and 24/30 mm) had been unsuccessful in three patients before treatment with the large diameter stent. Due to dislocation, the large diameter stent was anchored in four patients (2× intraoperatively with transmural sutures, 2× endoscopically with transnasally externalized threads). Treatment was successful in 11 of 11 patients. Stent placement and removal was easy and safe. The median residence time of the stent was 24 (range, 18-41) days. Stent dislocation occurred in four cases (36 %). It was treated by anchoring the stent. Mean follow-up was 25 (range, 14-40) months. No severe complication occurred during or after intervention and no patient was dysphagic. Using the novel large diameter, partially covered stent to seal leaks in the upper GI tract is safe and effective. The large diameter of the stent does not seem to injure the wall of the upper GI tract. However, stent dislocation sometimes requires anchoring of the stent with sutures or transnasally externalized threads.
Jirapinyo, Pichamol; Kröner, Paul T; Thompson, Christopher C
2018-04-01
BACKGROUND AND STUDY AIMS : Transoral outlet reduction (TORe), performed using a traditional interrupted or a recently described purse-string suture pattern, is effective at inducing short- and mid-term weight loss in patients with weight regain after Roux-en-Y gastric bypass (RYGB). We aimed to determine the technical feasibility and safety of purse-string TORe and to assess its impact on weight and metabolic profiles. RYGB patients undergoing purse-string TORe were included. The gastrojejunal anastomosis (GJA) was ablated using argon plasma coagulation or dissected using endoscopic submucosal dissection. A suture was used to place stitches around the GJA in a continuous ring fashion. The suture was cinched over a balloon (8 - 12 mm). The primary outcome was technical feasibility. Secondary outcomes were the percentage of total body weight lost (%TWL), adverse events, impact on comorbidities, and predictors of weight loss. 252 RYGB patients underwent 260 purse-string TORes. They had regained 52.6 ± 46.4 % of lost weight and weighed 107.6 ± 24.6 kg. The technical success rate was 100 %. At 6 and 12 months, %TWL was 9.6 ± 6.3 and 8.4 ± 8.2. Two serious adverse events (0.8 %) occurred: gastrointestinal bleeding and GJA stenosis. At 12 months, blood pressure, hemoglobin A 1c , and ALT had improved. Prior weight regain was associated with %TWL at 12 months ( β = 0.07, P = 0.007) after controlling for BMI, pouch size, and number of purse-string rings. Purse-string TORe to treat weight regain after RYGB is technically feasible and safe. Additionally, it is associated with improvement in weight and comorbidity profiles up to 12 months post-procedure. © Georg Thieme Verlag KG Stuttgart · New York.
Shape memory alloy-based biopsy device for active locomotive intestinal capsule endoscope.
Le, Viet Ha; Hernando, Leon-Rodriguez; Lee, Cheong; Choi, Hyunchul; Jin, Zhen; Nguyen, Kim Tien; Go, Gwangjun; Ko, Seong-Young; Park, Jong-Oh; Park, Sukho
2015-03-01
Recently, capsule endoscopes have been used for diagnosis in digestive organs. However, because a capsule endoscope does not have a locomotive function, its use has been limited to small tubular digestive organs, such as small intestine and esophagus. To address this problem, researchers have begun studying an active locomotive intestine capsule endoscope as a medical instrument for the whole gastrointestinal tract. We have developed a capsule endoscope with a small permanent magnet that is actuated by an electromagnetic actuation system, allowing active and flexible movement in the patient's gut environment. In addition, researchers have noted the need for a biopsy function in capsule endoscope for the definitive diagnosis of digestive diseases. Therefore, this paper proposes a novel robotic biopsy device for active locomotive intestine capsule endoscope. The proposed biopsy device has a sharp blade connected with a shape memory alloy actuator. The biopsy device measuring 12 mm in diameter and 3 mm in length was integrated into our capsule endoscope prototype, where the device's sharp blade was activated and exposed by the shape memory alloy actuator. Then the electromagnetic actuation system generated a specific motion of the capsule endoscope to extract the tissue sample from the intestines. The final biopsy sample tissue had a volume of about 6 mm(3), which is a sufficient amount for a histological analysis. Consequently, we proposed the working principle of the biopsy device and conducted an in-vitro biopsy test to verify the feasibility of the biopsy device integrated into the capsule endoscope prototype using the electro-magnetic actuation system. © IMechE 2015.
Implementation of real-time digital endoscopic image processing system
NASA Astrophysics Data System (ADS)
Song, Chul Gyu; Lee, Young Mook; Lee, Sang Min; Kim, Won Ky; Lee, Jae Ho; Lee, Myoung Ho
1997-10-01
Endoscopy has become a crucial diagnostic and therapeutic procedure in clinical areas. Over the past four years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholecystectomy, pelviscopic endometriosis, and surgical arthroscopy. In this study, we developed a computer system, which is composed of a frame grabber, a sound board, a VCR control board, a LAN card and EDMS. Also, computer system controls peripheral instruments such as a color video printer, a video cassette recorder, and endoscopic input/output signals. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards; namely Microsoft Windows as an operating system, TCP/IP as a network protocol and a time sequential database that handles both images and speech. For the purpose of data storage, we used MOD and CD- R. Digital endoscopic system was designed to be able to store, recreate, change, and compress signals and medical images. Computerized endoscopy enables us to generate and manipulate the original visual document, making it accessible to a virtually unlimited number of physicians.
St-Louis, Etienne; Chabot, Annie; Stagg, Hayden; Baird, Robert
2018-05-01
Subcutaneous endoscopically-assisted ligation (SEAL) for pediatric inguinal hernia repair has gained in popularity although variations in techniques exist. Peritoneal scarring by thermal injury has been described as an adjunct. We explored the hypothesized inverse-correlation between peritoneal scarring and recurrence after SEAL. We conducted a single-center retrospective review of all patients <18years old undergoing SEAL between 2010 and 2016 (REB-20172727). Demographics and outcomes were investigated. Univariate and multivariable logistic regressions were performed to evaluate the association between peritoneal scarring and recurrence. We identified 272 patients. Median age was 3years, 35% were female, and 19% were born premature. Median follow-up was 30months, ≥1 visit/patient. Bilaterality was noted in 35%. There were no reported cases of metachronous hernia, vas injury, testicular atrophy or chronic pain, and recurrence rate was 4.6%. Prematurity, unilateral repair, incarceration, and suture-type (Ti-Cron® vs. Ethibond®) had significant correlation with recurrence on univariate analysis (p<0.25). Surgeon experience did not. Peritoneal scarring, performed in 195 cases (72%), was not predictive of recurrence (adjusted OR=0.87, p=0.830) on multivariable analysis. The rate of complications with SEAL compares favorably to published data. Thermal injury was not associated with improved recurrence rates. The benefits of peritoneal scarring may not outweigh the risks. III - Retrospective Case-Control Study. Copyright © 2018. Published by Elsevier Inc.
Minimal access surgery of pediatric inguinal hernias: a review.
Saranga Bharathi, Ramanathan; Arora, Manu; Baskaran, Vasudevan
2008-08-01
Inguinal hernia is a common problem among children, and herniotomy has been its standard of care. Laparoscopy, which gained a toehold initially in the management of pediatric inguinal hernia (PIH), has managed to steer world opinion against routine contralateral groin exploration by precise detection of contralateral patencies. Besides detection, its ability to repair simultaneously all forms of inguinal hernias (indirect, direct, combined, recurrent, and incarcerated) together with contralateral patencies has cemented its role as a viable alternative to conventional repair. Numerous minimally invasive techniques for addressing PIH have mushroomed in the past two decades. These techniques vary considerably in their approaches to the internal ring (intraperitoneal, extraperitoneal), use of ports (three, two, one), endoscopic instruments (two, one, or none), sutures (absorbable, nonabsorbable), and techniques of knotting (intracorporeal, extracorporeal). In addition to the surgeons' experience and the merits/limitations of individual techniques, it is the nature of the defect that should govern the choice of technique. The emerging techniques show a trend toward increasing use of extracorporeal knotting and diminishing use of working ports and endoscopic instruments. These favor wider adoption of minimal access surgery in addressing PIH by surgeons, irrespective of their laparoscopic skills and experience. Growing experience, wider adoption, decreasing complications, and increasing advantages favor emergence of minimal access surgery as the gold standard for the treatment of PIH in the future. This article comprehensively reviews the laparoscopic techniques of addressing PIH.
ISHII, Yudo; TAHARA, Shigeyuki; TERAMOTO, Akira; MORITA, Akio
2014-01-01
In recent years, resections of midline skull base tumors have been conducted using endoscopic endonasal skull base (EESB) approaches. Nevertheless, many surgeons reported that cerebrospinal fluid (CSF) leakage is still a major complication of these approaches. Here, we report the results of our 42 EESB surgeries and discuss the advantages and limits of this approach for resecting various types of tumors, and also report our technique to overcome CSF leakage. All 42 cases involved midline skull base tumors resected using the EESB technique. Dural incisions were closed using nasoseptal flaps and fascia patch inlay sutures. Total removal of the tumor was accomplished in seven pituitary adenomas (33.3%), five craniopharyngiomas (62.5%), five tuberculum sellae meningiomas (83.3%), three clival chordomas (100%), and one suprasellar ependymoma. Residual regions included the cavernous sinus, the outside of the intracranial part of the internal carotid artery, the lower lateral part of the posterior clivus, and the posterior pituitary stalk. Overall incidence of CSF leakage was 7.1%. Even though the versatility of the approach is limited, EESB surgery has many advantages compared to the transcranial approach for managing mid-line skull base lesions. To avoid CSF leakage, surgeons should have skills and techniques for complete closure, including use of the nasoseptal flap and fascia patch inlay techniques. PMID:25446379
Development of a virtual reality training system for endoscope-assisted submandibular gland removal.
Miki, Takehiro; Iwai, Toshinori; Kotani, Kazunori; Dang, Jianwu; Sawada, Hideyuki; Miyake, Minoru
2016-11-01
Endoscope-assisted surgery has widely been adopted as a basic surgical procedure, with various training systems using virtual reality developed for this procedure. In the present study, a basic training system comprising virtual reality for the removal of submandibular glands under endoscope assistance was developed. The efficacy of the training system was verified in novice oral surgeons. A virtual reality training system was developed using existing haptic devices. Virtual reality models were constructed from computed tomography data to ensure anatomical accuracy. Novice oral surgeons were trained using the developed virtual reality training system. The developed virtual reality training system included models of the submandibular gland and surrounding connective tissues and blood vessels entering the submandibular gland. Cutting or abrasion of the connective tissue and manipulations, such as elevation of blood vessels, were reproduced by the virtual reality system. A training program using the developed system was devised. Novice oral surgeons were trained in accordance with the devised training program. Our virtual reality training system for endoscope-assisted removal of the submandibular gland is effective in the training of novice oral surgeons in endoscope-assisted surgery. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Comparison of manual steering and steering via joystick of a flexible rhino endoscope.
Eckl, R; Gumprecht, J J; Strauss, G; Hofer, M; Dietz, A; Lueth, T C
2010-01-01
Flexible endoscopes are used in ENT surgery for examination tasks in cases wherever rigid endoscopes are unsuitable to reach certain positions in the nasal cavity. Until today they are steered by hand and no robotized system has been put into clinical practice. One qualification a robot manipulator system has to fulfill to be accepted is not to create new disadvantages compared to the conventional method in surgery. An important factor is the time needed to steer the new system compared to the time needed to steer the conventional system. In this article a robot manipulator system and an experiment are presented to compare the particular times test persons need to perform a certain task. This approach offers the possibility to benchmark the developed robot manipulator system and future systems for flexible rhino endoscopes.
Smart tissue anastomosis robot (STAR): a vision-guided robotics system for laparoscopic suturing.
Leonard, Simon; Wu, Kyle L; Kim, Yonjae; Krieger, Axel; Kim, Peter C W
2014-04-01
This paper introduces the smart tissue anastomosis robot (STAR). Currently, the STAR is a proof-of-concept for a vision-guided robotic system featuring an actuated laparoscopic suturing tool capable of executing running sutures from image-based commands. The STAR tool is designed around a commercially available laparoscopic suturing tool that is attached to a custom-made motor stage and the STAR supervisory control architecture that enables a surgeon to select and track incisions and the placement of stitches. The STAR supervisory-control interface provides two modes: A manual mode that enables a surgeon to specify the placement of each stitch and an automatic mode that automatically computes equally-spaced stitches based on an incision contour. Our experiments on planar phantoms demonstrate that the STAR in either mode is more accurate, up to four times more consistent and five times faster than surgeons using state-of-the-art robotic surgical system, four times faster than surgeons using manual Endo360(°)®, and nine times faster than surgeons using manual laparoscopic tools.
Quality assurance manual of endoscopic screening for gastric cancer in Japanese communities.
Hamashima, Chisato; Fukao, Akira
2016-09-02
The Japanese government introduced endoscopic screening for gastric cancer in 2015 as a public policy based on the Japanese guidelines on gastric cancer screening. To provide appropriate endoscopic screening for gastric cancer in Japanese communities, we developed a quality assurance manual of endoscopic screening and recommend 10 strategies with their brief descriptions as follows: (i) Formulation of a committee responsible for implementing and managing endoscopic screening, and for deciding the suitable implementation methods in consideration of the local context; (ii) Development of an interpretation system that leads to a final judgement to standardize endoscopic examination and improve its accuracy; (iii) Preparation of management and reporting systems for adverse effects by the committee for safety management; (iv) Obtaining informed consent before operation following adequate explanations regarding the benefits and harms of endoscopic screening; (v) Avoidance of frequent screenings to reduce false-positive results and overdiagnosis. As a reference, the target age group is ≥50 years, and the screening interval is 2 years; (vi) Keeping the biopsy rate within 10% as post-biopsy bleeding may occur. Before endoscopic screening, any history of antithrombotic drug usage should be checked; (vii) Nonadministration of sedation in endoscopic screening for safety management; (viii) Adherence to proper endoscopic cleaning and disinfection to reduce infection; (ix) Use of a checklist to achieve optimal program preparation when municipal governments introduce endoscopic screening; (x) Identification of the aims and roles by referring to a checklist if primary care physicians decide to participate in endoscopic screening. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Laparoscopic Suturing as a Barrier to Broader Adoption of Laparoscopic Surgery.
Lim, Sangtaeck; Ghosh, Sudip; Niklewski, Paul; Roy, Sanjoy
2017-01-01
Laparoscopic surgery is increasingly replacing the open procedure because of its many patient-related benefits that are well aligned with policies and programs that seek to optimize health system performance. However, widespread adoption of laparoscopic surgery has been slow, in part, because of the complexity of laparoscopic suturing. The objective of this study was to review the clinical and economic impacts of laparoscopic suturing in key procedures and to assess its role as a barrier to the broader adoption of laparoscopic surgery. A medical literature search of MEDLINE, EMBASE, and BIOSIS from January 2010 through June 2016 identified 47 relevant articles. Laparoscopic suturing and intracorporeal knot tying may result in extended surgical time, complications, and surgeon errors, while improving patient quality of life through improved cosmesis, diet toleration, and better bowel movements. Despite advancement in surgical techniques and the availability of newer surgical tools, the complexity of laparoscopic suturing continues to be a barrier to greater adoption of MIS. The results of the study underscore the need for development of proficiency in laparoscopic suturing, which may help improve patient outcomes and reduce healthcare costs.
Flexor Tendon Repair With Looped Suture: 1 Versus 2 Knots.
Gil, Joseph A; Skjong, Christian; Katarincic, Julia A; Got, Christopher
2016-03-01
To assess the strength of flexor tendon repair with looped suture. We hypothesized that, after passing the intact looped suture in the desired repair configuration, splitting the loop and tying 2 independent knots would increase the strength of flexor tendon repair. Thirty-two flexor tendons were harvested and were sharply transected in zone II. The tendons were repaired with a 4-strand core suture repair using 3-0 looped nonabsorbable nylon suture. The harvested tendons were randomly assigned and repaired with either a 1- or a 2-knot construct. The repaired flexor tendons were fixed in a servohydraulic material testing system and were loaded to failure either with uniaxial tension or cyclically. The average force at failure was 43 N for the 1-knot repair and 28 N for the 2-knot repair. The mode of failure of 15 of the flexor tendon repairs that were cyclically loaded to failure was suture pull-out. The average number of cycles and force in cyclic testing that caused failure of flexor tendon repairs was 134 cycles and 31 N for tendons repaired with looped 3-0 suture tied with 1 knot and 94 cycles and 33 N for tendons repaired with looped 3-0 suture tied with 2 knots. Our hypothesis was disproved by the results of this study. This study suggests that, when using looped suture, tying 2 independent knots instead of tying a single knot does not increase the strength of the flexor tendon repair. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Otani, Naoki; Morimoto, Yuji; Fujii, Kazuya; Toyooka, Terushige; Wada, Kojiro; Mori, Kentaro
2017-12-01
Endoscopy can observe the anatomical components in a deeply located and/or hidden area during neurosurgical procedures under the operating microscope. We have newly developed a flexible ultrathin endoscope integrated with irrigation suction apparatus (FUEISA) to visualize deeply located and/or hidden areas for assisting microneurosurgery. The present study investigated the usefulness of the FUEISA system for direct clipping surgery of cerebral aneurysms. Twenty-one patients underwent microneurosurgery assisted with the FUEISA system for direct clipping of cerebral aneurysms. The flexible ultrathin endoscope (outer diameter 0.75mm) consists of an image guide (6000 dpi) and a light guide, integrated with the irrigation suction apparatus. This endoscopic system was inserted before and after clipping to observe the anatomical conditions surrounding the lesions. In all cases, handling and operation of the FUEISA was technically successful during the surgical procedure. The ultrathin endoscope was adequately integrated with the irrigation suction apparatus in all cases. General anatomy visualization including the lenticulostriate arteries, medial striate arteries, and/or internal carotid artery perforators was possible, and the correct clip positioning and vessel conditions were easily checked. The endoscope revealed that the clip had been positioned incorrectly in one case. No complications associated with the endoscopic system occurred. The FUEISA system can be applied with safe manipulation, which was remarkably useful for confirmation of the presence of perforators and cranial nerves behind the lesions, particularly anatomical components located in deep and/or hidden areas during clipping of cerebral aneurysms. Copyright © 2017 Elsevier Inc. All rights reserved.
Rathmayer, Markus; Heinlein, Wolfgang; Reiß, Claudia; Albert, Jörg G; Akoglu, Bora; Braun, Martin; Brechmann, Thorsten; Gölder, Stefan K; Lankisch, Tim; Messmann, Helmut; Schneider, Arne; Wagner, Martin; Dollhopf, Markus; Gundling, Felix; Röhling, Michael; Haag, Cornelie; Dohle, Ines; Werner, Sven; Lammert, Frank; Fleßa, Steffen; Wilke, Michael H; Schepp, Wolfgang; Lerch, Markus M
2017-10-01
Background In the German hospital reimbursement system (G-DRG) endoscopic procedures are listed in cost center 8. For reimbursement between hospital departments and external providers outdated or incomplete catalogues (e. g. DKG-NT, GOÄ) have remained in use. We have assessed the cost for endoscopic procedures in the G-DRG-system. Methods To assess the cost of endoscopic procedures 74 hospitals, annual providers of cost-data to the Institute for the Hospital Remuneration System (InEK) made their data (2011 - 2015; § 21 KHEntgG) available to the German-Society-of-Gastroenterology (DGVS) in anonymized form (4873 809 case-data-sets). Using cases with exactly one endoscopic procedure (n = 274 186) average costs over 5 years were calculated for 46 endoscopic procedure-tiers. Results Robust mean endoscopy costs ranged from 230.56 € for gastroscopy (144 666 cases), 276.23 € (n = 32 294) for a simple colonoscopy, to 844.07 € (n = 10 150) for ERCP with papillotomy and plastic stent insertion and 1602.37 € (n = 967) for ERCP with a self-expanding metal stent. Higher costs, specifically for complex procedures, were identified for University Hospitals. Discussion For the first time this catalogue for endoscopic procedure-tiers, based on § 21 KHEntgG data-sets from 74 InEK-calculating hospitals, permits a realistic assessment of endoscopy costs in German hospitals. The higher costs in university hospitals are likely due to referral bias for complex cases and emergency interventions. For 46 endoscopic procedure-tiers an objective cost-allocation within the G-DRG system is now possible. By international comparison the costs of endoscopic procedures in Germany are low, due to either greater efficiency, lower personnel allocation or incomplete documentation of the real expenses. © Georg Thieme Verlag KG Stuttgart · New York.
Yin, Gang; Han, Woong Kyu; Faddegon, Stephen; Tan, Yung Khan; Liu, Zhuo-Wei; Olweny, Ephrem O; Scott, Daniel J; Cadeddu, Jeffrey A
2013-01-01
To compare the ergonomics and workload of the surgeon during single-site suturing while using the magnetic anchoring and guidance system (MAGS) camera vs a conventional laparoscope. Seven urologic surgeons were enrolled and divided into an expert group (n=2) and a novice group (n=5) according to their laparoendoscopic single-site (LESS) experience. Each surgeon performed 2 conventional LESS and 2 MAGS camera-assisted LESS vesicostomy closures in a porcine model. A Likert scale (scoring 1-5) questionnaire assessing workload, ergonomics, technical difficulty, visualization, and needle handling, as well as a validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire were used to evaluate the tasks and workloads. MAGS LESS suturing was universally favored by expert and novice surgeons compared with conventional LESS in workload (3.4 vs 4.2), ergonomics (3.4 vs 4.4), technical challenge (3.3 vs 4.3), visualization (2.4 vs 3.3), and needle handling (3.1 vs 3.9 respectively; P<.05 for all categories). Surgeon NASA-TLX assessments found MAGS LESS suturing significantly decreased the workload in physical demand (P=.004), temporal demand (P=.017), and effort (P=.006). External instrument clashing was significantly reduced in MAGS LESS suturing (P<.001). The total operative time of MAGS LESS suturing was comparable to that of conventional LESS (P=.89). MAGS camera technology significantly decreased surgeon workload and improved ergonomics. Nevertheless, LESS suturing and knot tying remains a challenging task that requires training, regardless of which camera is used. Copyright © 2013 Elsevier Inc. All rights reserved.
3D imaging with a single-aperture 3-mm objective lens: concept, fabrication, and test
NASA Astrophysics Data System (ADS)
Korniski, Ronald; Bae, Sam Y.; Shearn, Michael; Manohara, Harish; Shahinian, Hrayr
2011-10-01
There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the- shelf (COTS) components including the ones used in the endoscope objective.
3D Imaging with a Single-Aperture 3-mm Objective Lens: Concept, Fabrication and Test
NASA Technical Reports Server (NTRS)
Korniski, Ron; Bae, Sam Y.; Shearn, Mike; Manohara, Harish; Shahinian, Hrayr
2011-01-01
There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the-shelf (COTS) components including the ones used in the endoscope objective.
Endoscopic techniques in aesthetic plastic surgery.
McCain, L A; Jones, G
1995-01-01
There has been an explosive interest in endoscopic techniques by plastic surgeons over the past two years. Procedures such as facial rejuvenation, breast augmentation and abdominoplasty are being performed with endoscopic assistance. Endoscopic operations require a complex setup with components such as video camera, light sources, cables and hard instruments. The Hopkins Rod Lens system consists of optical fibers for illumination, an objective lens, an image retrieval system, a series of rods and lenses, and an eyepiece for image collection. Good illumination of the body cavity is essential for endoscopic procedures. Placement of the video camera on the eyepiece of the endoscope gives a clear, brightly illuminated large image on the monitor. The video monitor provides the surgical team with the endoscopic image. It is important to become familiar with the equipment before actually doing cases. Several options exist for staff education. In the operating room the endoscopic cart needs to be positioned to allow a clear unrestricted view of the video monitor by the surgeon and the operating team. Fogging of the endoscope may be prevented during induction by using FREDD (a fog reduction/elimination device) or a warm bath. The camera needs to be white balanced. During the procedure, the nurse monitors the level of dissection and assesses for clogging of the suction.
A review of surgical repair methods and patient outcomes for gluteal tendon tears.
Ebert, Jay R; Bucher, Thomas A; Ball, Simon V; Janes, Gregory C
2015-01-01
Advanced hip imaging and surgical findings have demonstrated that a common cause of greater trochanteric pain syndrome (GTPS) is gluteal tendon tears. Conservative measures are initially employed to treat GTPS and manage gluteal tears, though patients frequently undergo multiple courses of non-operative treatment with only temporary pain relief. Therefore, a number of surgical treatment options for recalcitrant GTPS associated with gluteal tears have been reported. These have included open trans-osseous or bone anchored suture techniques, endoscopic methods and the use of tendon augmentation for repair reinforcement. This review describes the anatomy, pathophysiology and clinical presentation of gluteal tendon tears. Surgical techniques and patient reported outcomes are presented. This review demonstrates that surgical repair can result in improved patient outcomes, irrespective of tear aetiology, and suggests that the patient with "trochanteric bursitis" should be carefully assessed as newer surgical techniques show promise for a condition that historically has been managed conservatively.
Peng, Hanwei; Wang, Steven J; Li, Weixiong
2014-10-11
The most common complications after thyroidectomy are injuries associated with the recurrent laryngeal nerve and parathyroid gland. Cervical esophagus perforation is an exceptionally rare complication after thyroidectomy; it can usually be resolved by conservative care. Cervical esophageal stenosis secondary to intraoperative esophageal injury during thyroidectomy is much rarer and has not been reported in the literature to date. We report a case of esophageal stenosis following thyroidectomy performed at a peripheral hospital. The patient initially underwent a thyroidectomy for papillary thyroid carcinoma involving the cervical esophagus; esophageal perforation was noted intraoperatively, and closed using three number 4 silk sutures. Cervical esophageal stenosis subsequently developed after conservative care. The patient was successfully treated with cervical esophagectomy and reconstruction using a tubed forearm free flap after a failed attempt at endoscopic recanalization. This case is discussed in conjunction with a review of the literature.
Kakiuchi, Daiki; Saito, Kenichiro; Mitsui, Takeshi; Munemoto, Yoshinori; Takashima, Yoshihiro; Amaya, Susumu; Shimada, Masanari; Kato, Yosuke
2018-06-19
A 75-year-old woman underwent laparoscopic abdominoperineal resection. Four months after abdominoperineal resection, the patient complained of a perineal bulge and urination disorder. Abdominal CT showed protrusion of the small intestine and bladder to the perineum. The patient underwent laparoscopic hernia repair with mesh. The size of the hernial orifice was 7.0 × 9.0 cm, and it had no solid rim. The mesh was tacked ventrally to the pectineal ligament and dorsally to the sacrum, and then sutured on the lateral side. The hernia has not recurred 10 months after the operation. Laparoscopic repair is a good treatment choice for secondary perineal hernia and fixing the mesh to the pectineal ligament, and the sacrum prevents the mesh from sagging. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Endoscopic electrosurgical unit and accessories. (a) Identification. An endoscopic electrosurgical unit and... device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode, flexible snare, electrosurgical alarm system, electrosurgical power supply unit, electrical clamp, self...
Fitch, J.P.
1999-07-06
An endoscope is disclosed which reduces the volume needed by the imaging part, maintains resolution of a wide diameter optical system, while increasing tool access, and allows stereographic or interferometric processing for depth and perspective information/visualization. Because the endoscope decreases the volume consumed by imaging optics such allows a larger fraction of the volume to be used for non-imaging tools, which allows smaller incisions in surgical and diagnostic medical applications thus produces less trauma to the patient or allows access to smaller volumes than is possible with larger instruments. The endoscope utilizes fiber optic light pipes in an outer layer for illumination, a multi-pupil imaging system in an inner annulus, and an access channel for other tools in the center. The endoscope is amenable to implementation as a flexible scope, and thus increases it's utility. Because the endoscope uses a multi-aperture pupil, it can also be utilized as an optical array, allowing stereographic and interferometric processing. 7 figs.
Fitch, Joseph P.
1999-07-06
An endoscope which reduces the volume needed by the imaging part thereof, maintains resolution of a wide diameter optical system, while increasing tool access, and allows stereographic or interferometric processing for depth and perspective information/visualization. Because the endoscope decreases the volume consumed by imaging optics such allows a larger fraction of the volume to be used for non-imaging tools, which allows smaller incisions in surgical and diagnostic medical applications thus produces less trauma to the patient or allows access to smaller volumes than is possible with larger instruments. The endoscope utilizes fiber optic light pipes in an outer layer for illumination, a multi-pupil imaging system in an inner annulus, and an access channel for other tools in the center. The endoscope is amenable to implementation as a flexible scope, and thus increases the utility thereof. Because the endoscope uses a multi-aperture pupil, it can also be utilized as an optical array, allowing stereographic and interferometric processing.
Atalağ, Koray; Bilgen, Semih; Gür, Gürden; Boyacioğlu, Sedat
2007-09-01
There are very few evaluation studies for the Minimal Standard Terminology for Digestive Endoscopy. This study aims to evaluate the usage of the Turkish translation of Minimal Standard Terminology by developing an endoscopic information system. After elicitation of requirements, database modeling and software development were performed. Minimal Standard Terminology driven forms were designed for rapid data entry. The endoscopic report was rapidly created by applying basic Turkish syntax and grammar rules. Entering free text and also editing of final report were possible. After three years of live usage, data analysis was performed and results were evaluated. The system has been used for reporting of all endoscopic examinations. 15,638 valid records were analyzed, including 11,381 esophagogastroduodenoscopies, 2,616 colonoscopies, 1,079 rectoscopies and 562 endoscopic retrograde cholangiopancreatographies. In accordance with other previous validation studies, the overall usage of Minimal Standard Terminology terms was very high: 85% for examination characteristics, 94% for endoscopic findings and 94% for endoscopic diagnoses. Some new terms, attributes and allowed values were also added for better clinical coverage. Minimal Standard Terminology has been shown to cover a high proportion of routine endoscopy reports. Good user acceptance proves that both the terms and structure of Minimal Standard Terminology were consistent with usual clinical thinking. However, future work on Minimal Standard Terminology is mandatory for better coverage of endoscopic retrograde cholangiopancreatographies examinations. Technically new software development methodologies have to be sought for lowering cost of development and the maintenance phase. They should also address integration and interoperability of disparate information systems.
Analysis of a concentric-tube robot design and feasibility for endoscopic deployment
NASA Astrophysics Data System (ADS)
Ponten, Ryan; Black, Caroline B.; Russ, Andrew J.; Rucker, D. Caleb
2017-03-01
An intraluminal endoscopic approach is desirable for most colonoscopic procedures and is growing in favor for other surgeries as tools are enhanced. Flexible robotic manipulators could further enhance the dexterity and precision of commercial endoscopic systems. In this paper, we explore the capabilities of concentric tube robots to work as tool manipulators at the tip of a colonoscope to perform endoscopic submucousal dissection (ESD) and endoscopic full thickness resection (EFTR). We provide an overview of the kinematic modeling of these manipulators, a design of a prototype manipulator and the transmission actuation system. Our analysis examines the workspace and stiffness of these manipulators being controlled at the tip of a colonoscope. We compare the results to reported surgical requirements and propose solutions for enhancing their effectiveness including notching tubes with a larger Young's Modulus. We also determine the resolution and accuracy of the actuation system.
Li, Liang; Yang, Jian; Chu, Yakui; Wu, Wenbo; Xue, Jin; Liang, Ping; Chen, Lei
2016-01-01
Objective To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery. Materials and Methods In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems. Results The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons. Conclusion The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon’s skills and knowledge, not as a substitute. PMID:26757365
Li, Liang; Yang, Jian; Chu, Yakui; Wu, Wenbo; Xue, Jin; Liang, Ping; Chen, Lei
2016-01-01
To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery. In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems. The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons. The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon's skills and knowledge, not as a substitute.
Robotics and systems technology for advanced endoscopic procedures: experiences in general surgery.
Schurr, M O; Arezzo, A; Buess, G F
1999-11-01
The advent of endoscopic techniques changed surgery in many regards. This paper intends to describe an overview about technologies to facilitate endoscopic surgery. The systems described have been developed for the use in general surgery, but an easy application also in the field of cardiac surgery seems realistic. The introduction of system technology and robotic technology enables today to design a highly ergonomic solo-surgery platform. To relief the surgeon from fatigue we developed a new chair dedicated to the functional needs of endoscopic surgery. The foot pedals for high frequency, suction and irrigation are integrated into the basis of the chair. The chair is driven by electric motors controlled with an additional foot pedal joystick to achieve the desired position in the OR. A major enhancement for endoscopic technology is the introduction of robotic technology to design assisting devices for solo-surgery and manipulators for microsurgical instrumentation. A further step in the employment of robotic technology is the design of 'master-slave manipulators' to provide the surgeon with additional degrees of freedom of instrumentation. In 1996 a first prototype of an endoscopic manipulator system. named ARTEMIS, could be used in experimental applications. The system consists of a user station (master) and an instrument station (slave). The surgeon sits at a console which integrates endoscopic monitors, communication facilities and two master devices to control the two slave arms which are mounted to the operating table. Clinical use of the system, however, will require further development in the area of slave mechanics and the control system. Finally the implementation of telecommunication technology in combination with robotic instruments will open new frontiers, such as teleconsulting, teleassistance and telemanipulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Richard S.; Deters, Katherine A.; Cook, Katrina V.
Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the ability to make shorter incisions that may warrant using only a single suture for closure. However, it is not known if one suture will sufficiently hold the incision closed, particularly when outward pressure is placed on the surgical site such as when migrating fish experience pressure changes associated with passage at hydroelectric dams. The objective of this research was to evaluate the effectiveness of single-suture incision closures on juvenile Chinook salmon (Oncorhynchus tshawytscha). Juvenile Chinook salmon were surgically implanted with a 2012 Juvenile Salmonmore » Acoustic Telemetry System (JSATS) transmitter (0.30 g) and a passive integrated transponder tag (0.10 g) and incisions were closed with either one suture or two sutures. Mortality and tag retention were monitored and fish were examined after 7 and 14 days to evaluate tissue responses. In a separate experiment, surgically implanted fish were exposed to simulated turbine passage and then examined for expulsion of transmitters, expulsion of viscera through the incision, and mortal injury. With incisions closed using a single suture, there was no mortality or tag loss and similar or reduced tissue reaction compared to incisions closed with two sutures. Further, surgery time was significantly reduced when one suture was used, which leads to less handling and reduced stress. No tags were expelled during pressure scenarios and expulsion of viscera only occurred in two non-mortally injured fish (5%) with single sutures that were also exposed to very high pressure changes. No viscera expulsion was present in fish exposed to pressure scenarios likely representative of hydroturbine passage at many Columbia River dams (e.g. <2.7 ratio of pressure change; an acclimation pressure of 146.2 absolute kpa and a lowest exposure pressure of ~ 53.3 absolute kpa). Based on these results, we recommend the use of a single suture for surgical implantation of transmitters with incisions that are approximately 5 1/2 mm long after tag insertion.« less
Monitoring of endoscope reprocessing with an adenosine triphosphate (ATP) bioluminescence method.
Parohl, Nina; Stiefenhöfer, Doris; Heiligtag, Sabine; Reuter, Henning; Dopadlik, Dana; Mosel, Frank; Gerken, Guido; Dechêne, Alexander; Heintschel von Heinegg, Evelyn; Jochum, Christoph; Buer, Jan; Popp, Walter
2017-01-01
Background: The arising challenges over endoscope reprocessing quality proposes to look for possibilities to measure and control the process of endoscope reprocessing. Aim: The goal of this study was to evaluate the feasibility of monitoring endoscope reprocessing with an adenosine triphosphate (ATP) based bioluminescence system. Methods: 60 samples of eight gastroscopes have been assessed from routine clinical use in a major university hospital in Germany. Endoscopes have been assessed with an ATP system and microbial cultures at different timepoints during the reprocessing. Findings: After the bedside flush the mean ATP level in relative light units (RLU) was 19,437 RLU, after the manual cleaning 667 RLU and after the automated endoscope reprocessor (AER) 227 RLU. After the manual cleaning the mean total viable count (TVC) per endoscope was 15.3 CFU/10 ml, and after the AER 5.7 CFU/10 ml. Our results show that there are reprocessing cycles which are not able to clean a patient used endoscope. Conclusion: Our data suggest that monitoring of flexible endoscope with ATP can identify a number of different influence factors, like the endoscope condition and the endoscopic procedure, or especially the quality of the bedside flush and manual cleaning before the AER. More process control is one option to identify and improve influence factors to finally increase the overall reprocessing quality, best of all by different methods. ATP measurement seems to be a valid technique that allows an immediate repeat of the manual cleaning if the ATP results after manual cleaning exceed the established cutoff of 200 RLU.
Krishnamoorthy, Bhuvaneswari; Critchley, William R; Nair, Janesh; Malagon, Ignacio; Carey, John; Barnard, James B; Waterworth, Paul D; Venkateswaran, Rajamiyer V; Fildes, James E; Caress, Ann L; Yonan, Nizar
The aim of the study was to assess whether the use of carbon dioxide insufflation has any impact on integrity of long saphenous vein comparing 2 types of endoscopic vein harvesting and traditional open vein harvesting. A total of 301 patients were prospectively randomized into 3 groups. Group 1 control arm of open vein harvesting (n = 101), group 2 closed tunnel (carbon dioxide) endoscopic vein harvesting (n = 100) and Group 3 open tunnel (carbon dioxide) endoscopic vein harvesting (open tunnel endoscopic vein harvesting) (n = 100). Each group was assessed to determine the systemic level of partial arterial carbon dioxide, end-tidal carbon dioxide, and pH. Three blood samples were obtained at baseline, 10 minutes after start of endoscopic vein harvesting, and 10 minutes after the vein was retrieved. Vein samples were taken immediately after vein harvesting without further surgical handling to measure the histological level of endothelial damage. A modified validated endothelial scoring system was used to compare the extent of endothelial stretching and detachment. The level of end-tidal carbon dioxide was maintained in the open tunnel endoscopic vein harvesting and open vein harvesting groups but increased significantly in the closed tunnel endoscopic vein harvesting group (P = 0.451, P = 0.385, and P < 0.001). Interestingly, partial arterial carbon dioxide also did not differ over time in the open tunnel endoscopic vein harvesting group (P = 0.241), whereas partial arterial carbon dioxide reduced significantly over time in the open vein harvesting group (P = 0.001). A profound increase in partial arterial carbon dioxide was observed in the closed tunnel endoscopic vein harvesting group (P < 0.001). Consistent with these patterns, only the closed tunnel endoscopic vein harvesting group demonstrated a sudden drop in pH over time (P < 0.001), whereas pH remained stable for both open tunnel endoscopic vein harvesting and open vein harvesting groups (P = 0.105 and P = 0.869, respectively). Endothelial integrity was better preserved in the open vein harvesting group compared with open tunnel endoscopic vein harvesting or closed tunnel endoscopic vein harvesting groups (P = 0.012) and was not affected by changes in carbon dioxide or low pH. Significantly greater stretching of the endothelium was observed in the open tunnel endoscopic open tunnel endoscopic vein harvesting group compared with the other groups (P = 0.003). This study demonstrated that the different vein harvesting techniques impact on endothelial integrity; however, this does not seem to be related to the increase in systemic absorption of carbon dioxide or to the pressurized endoscopic tunnel. The open tunnel endoscopic harvesting technique vein had more endothelial stretching compared with the closed tunnel endoscopic technique; this may be due to manual dissection of the vein. Further research is required to evaluate the long-term clinical outcome of these vein grafts.
Hyperammonemic encephalopathy due to suture line breakdown after bladder operation.
Boogerd, W; Zoetmulder, F A; Moffie, D
1990-01-01
A patient is described with a severe encephalopathy and hyperammonemia in absence of liver dysfunction, attributed to urine absorption into the systemic circulation due to suture line breakdown after bladder dome resection. At autopsy characteristic Alzheimer type II astrocytes were found in the basal ganglia.
Advanced Endoscopic Navigation: Surgical Big Data, Methodology, and Applications.
Luo, Xiongbiao; Mori, Kensaku; Peters, Terry M
2018-06-04
Interventional endoscopy (e.g., bronchoscopy, colonoscopy, laparoscopy, cystoscopy) is a widely performed procedure that involves either diagnosis of suspicious lesions or guidance for minimally invasive surgery in a variety of organs within the body cavity. Endoscopy may also be used to guide the introduction of certain items (e.g., stents) into the body. Endoscopic navigation systems seek to integrate big data with multimodal information (e.g., computed tomography, magnetic resonance images, endoscopic video sequences, ultrasound images, external trackers) relative to the patient's anatomy, control the movement of medical endoscopes and surgical tools, and guide the surgeon's actions during endoscopic interventions. Nevertheless, it remains challenging to realize the next generation of context-aware navigated endoscopy. This review presents a broad survey of various aspects of endoscopic navigation, particularly with respect to the development of endoscopic navigation techniques. First, we investigate big data with multimodal information involved in endoscopic navigation. Next, we focus on numerous methodologies used for endoscopic navigation. We then review different endoscopic procedures in clinical applications. Finally, we discuss novel techniques and promising directions for the development of endoscopic navigation.
The universal serial bus endoscope: design and initial clinical experience.
Hernandez-Zendejas, Gregorio; Dobke, Marek K; Guerrerosantos, Jose
2004-01-01
Endoscopic forehead lift is a well-established procedure in aesthetic plastic surgery. Many agree that currently available video-endoscopic equipment is bulky, multipieced and sometimes cumbersome in the operating theater. A novel system, the Universal Serial Bus Endoscope (USBE) was designed to simplify and reduce the number of necessary equipment pieces in the endoscopic setup. The USBE is attached by a single cable to a Universal Serial Bus (USB) port of a laptop computer. A built-in miniaturized cold light source provides illumination. A built-in digital camera chip enables procedure recording. The real-time images and movies obtained with USBE are displayed on the computer's screen and recorded on the laptop's hard disk drive. In this study, 25 patients underwent endoscopic browlift using the USBE system to test its clinical usefulness, all with good results and without complications or need for revision. The USBE was found to be reliable and easier to use than current video-endoscope equipment. The operative time needed to complete the procedure by the authors was reduced approximately 50%. The design and main technical characteristics of the USBE are presented.
NASA Astrophysics Data System (ADS)
Tran, Peter H.; Mukai, David S.; Brenner, Matthew; Chen, Zhongping
2004-06-01
A novel endoscopic optical coherence tomography probe was designed and constructed with a 1.9-mm microelectromechanical system (MEMS) motor. The new MEMS endoscopic probe design eliminates the need to couple the rotational energy from the proximal to the distal end of the probe. Furthermore, the endoscopic probe's sheath and fiber have the advantages of having a much smaller diameter and being more flexible than traditional endoscopes since no reinforcement is needed to couple the rotational torque. At the distal end, a prism mounted on a micromotor deflects the light rays to create a transverse circular-scanning pathway. Because our MEMS scanner does not require the coupling of a rotational single-mode fiber, a high scanning speed is possible while eliminating unstable optical signals caused by nonuniform coupling.
Comparison of functional results of two fixation systems using single-row suturing of rotator cuff.
Muniesa-Herrero, M P; Torres-Campos, A; Urgel-Granados, A; Blanco-Llorca, J A; Floría-Arnal, L J; Roncal-Boj, J C; Castro-Sauras, A
Arthroscopic repair of rotator cuff disorders is a technically demanding but successful procedure. Many anchor and suture alternatives are now available. The choice of the implant by the surgeon is less important than the configuration of the suture used to fix the tendon, however it is necessary to know if there are differences in the results, using each one of them. The aim of the study is to evaluate if there are differences between the knotted and non-knotted implant in terms of functional and satisfaction results. A retrospective study was carried out on 83 patients operated between 2010 and 2014 in our center using 2anchoring systems with and without knotting (39 versus 44 patients respectively), with single row in complete rupture of the rotator cuff. At the end of the follow-up, an average score was obtained on the Constant scale of 74.6 points. 98% of the patients considered the result of the surgery satisfactory. Statistically, there were no significant differences between the 2groups in terms of functionality, satisfaction or reincorporation to activities. The functional results of the single-row cuff suture are satisfactory, although biomechanical studies show advantages in favor of sutures that reproduce a transoseo system. It our series of patients the presence of knotting does not show per se a significant functional difference being both superimposable techniques in absolute values of functionality and patient satisfaction. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Development of terahertz endoscopic system for cancer detection
NASA Astrophysics Data System (ADS)
Doradla, Pallavi; Alavi, Karim; Joseph, Cecil S.; Giles, Robert H.
2016-02-01
Terahertz (THz) imaging is emerging as a robust platform for a myriad of applications in the fields of security, health, astronomy and material science. The terahertz regime with wavelengths spanning from microns to millimeters is a potentially safe and noninvasive medical imaging modality for detecting cancers. Endoscopic imaging systems provide high flexibility in examining the interior surfaces of an organ or tissue. Researchers have been working on the development of THz endoscopes with photoconductive antennas, which necessarily operate under high voltage, and require at least two channels to measure the reflected signal from the specimen. This manuscript provides the design and imperative steps involved in the development of a single-channel terahertz endoscopic system. The continuous-wave terahertz imaging system utilizes a single flexible terahertz waveguide channel to transmit and collect the back reflected intrinsic terahertz signal from the sample and is capable of operation in both transmission and reflection modalities. To determine the feasibility of using a terahertz endoscope for cancer detection, the co- and cross-polarized terahertz remittance from human colonic tissue specimens were collected at 584 GHz frequency. The two dimensional terahertz images obtained using polarization specific detection exhibited intrinsic contrast between cancerous and normal regions of fresh colorectal tissue. The level of contrast observed using endoscopic imaging correlates well with the contrast levels observed in the free space ex vivo terahertz reflectance studies of human colonic tissue. The prototype device developed in this study represents a significant step towards clinical endoscopic application of THz technology for in vivo colon cancer screening.
Catheter-based photoacoustic endoscope
Yang, Joon-Mo; Li, Chiye; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.
2014-01-01
Abstract. We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique’s benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument’s flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system. PMID:24887743
Experimental assessment of a 3-D plenoptic endoscopic imaging system.
Le, Hanh N D; Decker, Ryan; Krieger, Axel; Kang, Jin U
2017-01-01
An endoscopic imaging system using a plenoptic technique to reconstruct 3-D information is demonstrated and analyzed in this Letter. The proposed setup integrates a clinical surgical endoscope with a plenoptic camera to achieve a depth accuracy error of about 1 mm and a precision error of about 2 mm, within a 25 mm × 25 mm field of view, operating at 11 frames per second.
Experimental assessment of a 3-D plenoptic endoscopic imaging system
Le, Hanh N. D.; Decker, Ryan; Krieger, Axel; Kang, Jin U.
2017-01-01
An endoscopic imaging system using a plenoptic technique to reconstruct 3-D information is demonstrated and analyzed in this Letter. The proposed setup integrates a clinical surgical endoscope with a plenoptic camera to achieve a depth accuracy error of about 1 mm and a precision error of about 2 mm, within a 25 mm × 25 mm field of view, operating at 11 frames per second. PMID:29449863
Laparoscopic Suturing as a Barrier to Broader Adoption of Laparoscopic Surgery
Ghosh, Sudip; Niklewski, Paul; Roy, Sanjoy
2017-01-01
Background: Laparoscopic surgery is increasingly replacing the open procedure because of its many patient-related benefits that are well aligned with policies and programs that seek to optimize health system performance. However, widespread adoption of laparoscopic surgery has been slow, in part, because of the complexity of laparoscopic suturing. The objective of this study was to review the clinical and economic impacts of laparoscopic suturing in key procedures and to assess its role as a barrier to the broader adoption of laparoscopic surgery. Database: A medical literature search of MEDLINE, EMBASE, and BIOSIS from January 2010 through June 2016 identified 47 relevant articles. Conclusion: Laparoscopic suturing and intracorporeal knot tying may result in extended surgical time, complications, and surgeon errors, while improving patient quality of life through improved cosmesis, diet toleration, and better bowel movements. Despite advancement in surgical techniques and the availability of newer surgical tools, the complexity of laparoscopic suturing continues to be a barrier to greater adoption of MIS. The results of the study underscore the need for development of proficiency in laparoscopic suturing, which may help improve patient outcomes and reduce healthcare costs. PMID:28694682
Liu, Rui Wen; Lam, Patrick Hong; Shepherd, Henry M.; Murrell, George A. C.
2017-01-01
Background: Rotator cuff retears after surgical repair are associated with poorer subjective and objectives clinical outcomes than intact repairs. Purpose: The aims of this study were to (1) examine the biomechanical differences between rotator cuff repair using No. 2 suture and tape in an ovine model and (2) compare early clinical outcomes between patients who had rotator cuff repair with tape and patients who had repair with No. 2 suture. Study Design: Controlled laboratory study and cohort study; Level of evidence, 3. Methods: Biomechanical testing of footprint contact pressure and load to failure were conducted with 16 ovine shoulders using a tension band repair technique with 2 different types of sutures (No. 2 suture [FiberWire; Arthrex] and tape [FiberTape; Arthrex]) with the same knotless anchor system. A retrospective study of 150 consecutive patients (tape, n = 50; suture, n = 100) who underwent arthroscopic rotator cuff repair by a single surgeon with tear size larger than 1.5 × 1 cm was conducted. Ultrasound was used to evaluate the repair integrity at 6 months postsurgery. Results: Rotator cuff repair using tape had greater footprint contact pressure (mean ± standard error of the mean, 0.33 ± 0.03 vs 0.11 ± 0.3 MPa; P < .0001) compared with repair using No. 2 sutures at 0° abduction with a 30-N load applied across the repaired tendon. The ultimate failure load of the tape repair was greater than that for suture repair (217 ± 28 vs 144 ± 14 N; P < .05). The retear rate was similar between the tape (16%; 8/50) and suture groups (17%; 17/100). Conclusion: Rotator cuff repair with the wider tape compared with No. 2 suture did not affect the retear rate at 6 months postsurgery, despite having superior biomechanical properties. PMID:28451619
East, James E; Vleugels, Jasper L; Roelandt, Philip; Bhandari, Pradeep; Bisschops, Raf; Dekker, Evelien; Hassan, Cesare; Horgan, Gareth; Kiesslich, Ralf; Longcroft-Wheaton, Gaius; Wilson, Ana; Dumonceau, Jean-Marc
2016-11-01
Background and aim: This technical review is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the utilization of advanced endoscopic imaging in gastrointestinal (GI) endoscopy. Methods: This technical review is based on a systematic literature search to evaluate the evidence supporting the use of advanced endoscopic imaging throughout the GI tract. Technologies considered include narrowed-spectrum endoscopy (narrow band imaging [NBI]; flexible spectral imaging color enhancement [FICE]; i-Scan digital contrast [I-SCAN]), autofluorescence imaging (AFI), and confocal laser endomicroscopy (CLE). The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was adopted to define the strength of recommendation and the quality of evidence. Main recommendations: 1. We suggest advanced endoscopic imaging technologies improve mucosal visualization and enhance fine structural and microvascular detail. Expert endoscopic diagnosis may be improved by advanced imaging, but as yet in community-based practice no technology has been shown consistently to be diagnostically superior to current practice with high definition white light. (Low quality evidence.) 2. We recommend the use of validated classification systems to support the use of optical diagnosis with advanced endoscopic imaging in the upper and lower GI tracts (strong recommendation, moderate quality evidence). 3. We suggest that training improves performance in the use of advanced endoscopic imaging techniques and that it is a prerequisite for use in clinical practice. A learning curve exists and training alone does not guarantee sustained high performances in clinical practice. (Weak recommendation, low quality evidence.) Conclusion: Advanced endoscopic imaging can improve mucosal visualization and endoscopic diagnosis; however it requires training and the use of validated classification systems. © Georg Thieme Verlag KG Stuttgart · New York.
Hazratwala, Kaushik; Best, Alistair; Kopplin, Matthew; Giza, Eric; Sullivan, Martin
2005-03-01
The modified Broström ligament reconstruction using anchor sutures has been performed in adults with clinical success; however, the safety parameters for the use of suture anchors in adolescent lateral ankle ligament reconstruction have not been established. To perform a radiographic analysis comparing the depth of penetration of suture anchors in adult ankle ligament reconstruction with the average distance of the physis from the tip of the fibula in adolescents. Cross-sectional study, Level of evidence, 4. Forty postoperative ankle radiographs of adult patients who had a modified Broström procedure were compared with 40 normal adolescent ankle radiographs. In the adult group, the distance of the suture anchor penetration from the distal tip of the fibula was measured; in the adolescent group, the distance of the physis from the distal tip of the fibula was measured. The mean depth of the suture anchors was 17 mm (range, 14-21 mm) from the tip of the fibula in the adult group, and the mean distance of the growth plate was 23 mm (range, 18-29 mm) in the adolescent group. Eight radiographs from the adolescent group (20%) had a physis measurement of <22 mm on the anteroposterior or mortise view. Using careful preoperative planning and intraoperative technique, it is possible to safely perform lateral ankle ligament repair in the skeletally immature patient using suture anchors.
Statham, Melissa McCarty; Willging, J Paul
2010-10-01
Guidelines issued by the Association of Operating Room Nurses and the Association of Professionals in Infection Control and Epidemiology recommend high-level disinfection (HLD) for semicritical instruments, such as flexible endoscopes. We aim to examine the durability of endoscopes to continued use and automated HLD. We report the number of duty cycles a flexible endoscope can withstand before repairs should be anticipated. Retrospective review. A total of 4,336 endoscopic exams and subsequent disinfection cycles were performed with 60 flexible endoscopes in an outpatient tertiary pediatric otolaryngology practice from 2005 to 2009. All endoscopes were systemically cleaned with mechanical cleansing followed by leak testing, enzymatic cleaning, and exposure to Orthophthaldehyde (0.55%) for 5 minutes at a temperature of at least 25°C, followed by rinsing for 3 minutes. A total of 77 repairs were performed, 48 major (average cost $3,815.97), and 29 minor (average cost $326.85). On average, the 2.2-mm flexible endoscopes were utilized for 61.9 examinations before major repair was needed, whereas the 3.6 mm endoscopes were utilized for 154.5 exams before needing minor repairs. No major repairs have been needed to date on the 3.6-mm endoscopes. Automated endoscope reprocessor use for HLD is an effective means to disinfect and process flexible endoscopes. This minimizes variability in the processing of the endoscopes and maximizes the rate of successful HLD. Even when utilizing standardized, automated HLD and limiting the number of personnel processing the endoscopes, smaller fiberoptic endoscopes demonstrate a shortened time interval between repairs than that seen with the larger endoscopes. Laryngoscope, 2010.
Mohanty, Aaron; Thompson, Bobbye Jo; Patterson, Joel
2013-11-01
Conventionally, neuroendoscopic excision of intraventricular tumors has been difficult and time consuming because of lack of an effective decompression system that can be used through the working channel of the endoscope. The authors report their initial experience in purely endoscopic excision of large intraventricular tumors with the minimally invasive NICO Myriad system. The NICO Myriad is a side cutting soft tissue aspiration system that uses an inner reciprocating cannula and an outer stationary sheath with a side port. During decompression, applied suction approximates the tumor into the lumen of the outer sheath, with the inner cannula excising the tissue by oscillation of the cutting edge. The tumor is then removed by aspiration through the inner sheath. Three patients with large intraventricular tumors were operated by a purely endoscopic approach using a GAAB rigid endoscope and the NICO Myriad system. Of these, two had intraventricular craniopharyngiomas and one had a lateral ventricular subependymoma. The tumor size varied between 1.9 and 4.5 cm in the largest diameter. A relatively firm and solid tumor was encountered in two and a multicystic tumor with thick adherent walls in one. The tumor could be subtotally removed in one and near totally in two. There were no long-term complications. The NICO Myriad is a highly effective tumor decompression system that can be effectively used in a purely endoscopic approach to intraventricular lesions. Copyright © 2013 Elsevier Inc. All rights reserved.
Anesthetic management of the SRS™ Endoscopic Stapling System for gastro-esophageal reflux disease.
Topuz, Ufuk; Umutoglu, Tarik; Bakan, Mefkur; Ozturk, Erdogan
2013-01-14
The SRS(TM) Endoscopic Stapling System (Medigus, Tel Aviv, Israel) is a new tool capable of creating a totally endoscopic fundoplication, combined with an endoscope, endoscopic ultrasound and a surgical stapler. SRS(TM) endoscopic stapling for gastro-esophageal reflux disease is a minimally invasive, outpatient procedure, which requires general anesthesia with positive-pressure ventilation. Keeping the patient on positive end-expiratory pressure (PEEP) may minimize the pressure gradient between the esophagus and the mediastinum, as well as help to prevent air from leaking around the screws and causing pneumomediastinum. In addition, in patients with hiatal hernia, higher PEEP levels may be required to increase intra-thoracic pressure and to force the stomach to slide into the abdomen for ease of endoscopy. We advise smoother emergence from anesthesia, taking precautions for retching, postoperative nausea and vomiting (PONV), while coughing and gagging during extubation and PONV may affect the success of the procedure. Total intravenous anesthesia with propofol and remifentanil seems to be a good choice for these reasons.
Novel endoscopic delivery modality of infrared coagulation therapy for internal hemorrhoids.
McLemore, Elisabeth C; Rai, Rudra; Siddiqui, Junaid; Basu, P Patrick; Tabbaa, Mousab; Epstein, Michael S
2012-11-01
A novel endoscopic delivery system for infrared coagulation therapy (IRC) has been designed recently. IRC is a well-established treatment for symptomatic internal hemorrhoids. Patients frequently undergo lower endoscopy before hemorrhoid treatment to eliminate other sources of bleeding. Current treatment options are difficult to perform without an anal retractor, adequate lighting, and specialized instruments. Endoscopic IRC is an attractive alternative to standard IRC, because it can be performed during the lower endoscopy. Endoscopic IRC utilizes infrared radiation generated by a control box, which is applied to the tissue through a flexible, fiber optic light guide (Precision Endoscopic Infrared Coagulator™). The light guide is placed through the colonoscope or flexible sigmoidoscope in the same chamber as other endoscopic instruments. A retrospective review was performed using a prospectively collected database. A standardized protocol was utilized in all patients. Patients graded their symptoms before and after therapy by using the visual analog symptom severity scoring system (range, 0-10). These results were analyzed by using the nonparametric Wilcoxon signed-rank test. Exact P values were computed by using the R function wilcox.exact. A total of 55 patients underwent endoscopic IRC for predominately grade II and grade III symptomatic internal hemorrhoids (71 %). There were 22 (40 %) female patients. Posttherapy results indicated a significant improvement in global symptoms (pretreatment average global score = 2.24 vs. posttreatment average global score = 0.28; P < 0.0001). There have been no adverse events reported to date. Endoscopic IRC provides improved visibility and efficiency, allowing simultaneous treatment of symptomatic internal hemorrhoids at the time of lower endoscopy. Patients experienced significant improvement in their symptoms after a single session of endoscopic IRC. There are a variety of additional endoscopic IRC therapeutic utilities: endoscopic management of angiodysplasia, inflammation, hemostasis, and NOTES applications.
De Carli, Angelo; Lanzetti, Riccardo Maria; Monaco, Edoardo; Labianca, Luca; Mossa, Luigi; Ferretti, Andrea; Feretti, Andrea
2012-11-01
Despite technical advances in rotator cuff surgery, recurrent or persistent defects in the repaired tendon continue to occur. The improved strength of sutures and suture anchors has shown that the most common site of failure is the suture-tendon interface. The purpose of this study was to compare two different types of repair under both cyclic and load-to-failure conditions. The hypothesis is that the use of a fixation system with knotless anchor and taped suture results in better biomechanical performance, under both cyclic and load-to-failure conditions. Thirty bovine shoulder specimens were randomly assigned to two group tests: the Swivelock 5-mm anchor with Fibertape (Group A) and the Bio-Corkscrew 5 mm with Fiberwire (Group B). We simulated the reconstruction of a rotator cuff tear with a single-row technique, performing a tenodesis with types A and B fixation. Each specimen underwent cyclic testing from 5 to 30 N for 30 cycles, followed by load-to-failure testing, in order to calculate the ultimate failure load (UFL). Load-to-failure tests revealed a significantly higher UFL in Group A than in Group B. Wire fixing failed at the anchor loop whereas tape fixing failed at the sutures, suture-tendon interface, and anchors. Cyclic testing revealed no significantly greater slippage between the two groups. Stiffness values were not statistically significantly different. In all cases, tendons remained intact until the end of the cyclic testing. The tape structure is biomechanically stronger than the wire structure.
History and current status of mini-invasive thoracic surgery
He, Jianxing
2011-01-01
Mini-invasive thoracic technique mainly refers to a technique involving the significant reduction of the chest wall access-related trauma. Notably, thoracoscope is the chief representative. The development of thoracoscope technique is characterized by: developing from direct peep to artificial lighting, then combination with image and video technique in equipments; technically developing from diagnostic to therapeutic approaches; developing from simpleness to complexity in application scope; and usually developing together with other techniques. At present, the widely used mini-invasive thoracic surgery refers to the mini-open thoracic surgery performed mainly by using some instruments to control target tissues and organs based on the vision associated with multi-limb coordination, which may be hand-assisted if necessary. The mini-invasive thoracic surgery consists of three approaches including video-assisted thoracic surgery (VATS), video-assisted Hybrid and hand-assisted VATS. So far the mini-invasive thoracic technique has achieved great advances due to the development in instruments of mini-invasive thoracic surgery which has the following features: instruments of mini-invasive thoracic surgery appear to be safe and practical, and have successive improvement and diversification in function; the specific instruments of open surgeries has been successively developed into dedicated instruments of endoscopic surgery; the application of endoscopic mechanical suture device generates faster fragmentation and reconstruction of organ tissues; the specific delicated instruments of endoscopic surgery have rapid development and application; and the simple instruments structurally similar to the conventional instruments are designed according to the mini-incison. In addition, the mini-invasive thoracic technique is widely used in five aspects including diseases of pleura membrane and chest wall, lung diseases, esophageal diseases, mediastinal diseases and heart diseases. However, there remain many problems in specifications and trainings, economic cost, conservation and innovation. Therefore, particular attention should be paid to these problems. Nevertheless, the promotion of thoracic surgery appears promising in the future. PMID:22263074
Genco, Alfredo; Soricelli, Emanuele; Casella, Giovanni; Maselli, Roberta; Castagneto-Gissey, Lidia; Di Lorenzo, Nicola; Basso, Nicola
2017-04-01
Morbidly obese patients are affected by gastroesophageal reflux disease (GERD) and hiatal hernia (HH) more frequently than lean patients. Because of conflicting results, the indication to sleeve gastrectomy (SG) in patients with GERD is still debated. To evaluate the incidence of GERD on the basis of clinical, endoscopic, and histologic data in patients undergoing SG. University hospital, Rome, Italy. From July 2007 to January 2010, 162 patients underwent primary SG. Preoperatively all patients underwent visual analogue scale (VAS) evaluation of GERD symptoms, proton pump inhibitors (PPIs) consumption recording, and esophagogastroduodenoscopy (EGD). Stomach resection started 6 cm from pylorus on a 48Fr bougie. Staple line was reinforced by an oversewing suture. A postoperative clinical control with VAS evaluation, PPI consumption, and EGD was proposed to all patients. Three patients were excluded because of the occurrence of major postoperative complications. A total of 110 patients accepted to take part in the study (follow-up rate: 69.1%). At a mean 58 months of follow-up, incidence of GERD symptoms, VAS mean score, and PPI intake significantly increased compared with preoperative values (68.1% versus 33.6%: P<.0001; 3 versus 1.8: P = .018; 57.2% versus 19.1%: P<.0001) At EGD, an upward migration of the "Z" line and a biliary-like esophageal reflux was found in 73.6% and 74.5% of cases, respectively. A significant increase in the incidence and in the severity of erosive esophagitis (EE) was evidenced, whereas nondysplastic Barrett's esophagus (BE) was newly diagnosed in 19 patients (17.2%). No significant correlations were found between GERD symptoms and endoscopic findings. In the present series the incidence of EE and of BE in SG patients was considerably higher than that reported in the current literature, and it was not related to GERD symptoms. Endoscopic surveillance after SG should be advocated irrespective of the presence of GERD symptoms. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Vilmann, P; Hancke, S; Pless, T; Schell-Hincke, J D; Henriksen, F W
1998-10-01
We report here the first case of a one-step endosonography(EUS)-guided pseudocyst drainage. A prototype large channel curved array echo endoscope (Pentax FG-38 UX) and a prototype delivery system for placement of an endoprosthesis was used for the procedure. The delivery system (GIP MedicinTechnik GmbH/Medi-Globe Corporation) consists of a handle part with a piston, a metal ring sheath, a plastic catheter with a diathermy needle and a double pigtail endoprosthesis (8.5 Fr). When mounted on the endoscope the endoprosthesis can be advanced out of the distal end of the endoscope. The introduction of the stent as well as the stent release can be monitored entirely by ultrasound. The procedure was tested in a 76-year-old woman with a pseudocyst measuring 60 mm in diameter located in the tail of the pancreas. The procedure was well tolerated by the patient, and there were no procedural complications. The advantage of a large channel echo endoscope and our new prototype delivery system is that the endoprosthesis can be inserted in to a pancreatic cyst guided exclusively by EUS without exchange of endoscopes, catheters or guide wires. Further studies are warranted.
Efird, Chad; Traub, Shaun; Baldini, Todd; Rioux-Forker, Dana; Spalazzi, Jeffrey P; Davisson, Twana; Hawkins, Monica; McCarty, Eric
2013-08-01
The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity. Single-row repairs were performed with either type I (Opus Magnum PI; ArthroCare, Austin, Texas) or type II (ReelX STT; Stryker, Mahwah, New Jersey) knotless suture anchors. The repaired tendon was cycled from 10 to 90 N for 500 cycles, followed by load to failure. Gap formation was measured at 5, 100, 200, 300, 400, and 500 cycles with a video digitizing system. Anchor type or location (anterior or posterior) had no effect on gap formation during cyclic loading regardless of position (anterior, P=.385; posterior, P=.389). Maximum load to failure was significantly greater (P=.018) for repairs performed with type II anchors (288±62 N) compared with type I anchors (179±39 N). Primary failure modes were anchor pullout and tendon tearing for type II anchors and suture slippage through the anchor for type I anchors. The internal ratcheting suture-retention mechanism of type II anchors may have helped this anchor outperform the suture-cinching mechanism of type I anchors by supporting significantly higher loads before failure and minimizing suture slippage, potentially leading to stronger repairs clinically. Copyright 2013, SLACK Incorporated.
Cho, Won-Sang; Kim, Jeong Eun; Kang, Hyun-Seung; Ha, Eun Jin; Jung, Minwoong; Lee, Choonghee; Shin, Il Hyung; Kang, Uk
2017-04-01
Neuroendoscopy is useful for assessing status of perforators, parent arteries, and aneurysms beyond the straight line of microscopic view during aneurysm clipping. We aimed to evaluate the clinical usefulness of our endoscopic indocyanine green angiography (ICGA) system, which can simultaneously display visible light and indocyanine green fluorescent images. Surgical clipping of 16 unruptured aneurysms in 10 patients was performed via the keyhole approach. Using our endoscopic ICGA and commercial microscopic ICGA systems, we prospectively compared 10 targeted cerebral aneurysms at the posterior communicating (n = 4) and anterior choroidal (n = 6) arteries. Microscopic ICGA and endoscopic ICGA were feasible during surgery. Microscopic ICGA displayed 50% of branch orifices, 100% of branch trunks, and 20% of exact clip positions, whereas endoscopic ICGA showed 100% of these. Based on endoscopic ICGA findings such as incomplete clipping and compromise of parent arteries or branches, clips were repositioned in 2 cases, and additional clips were applied in 2 cases. Complete occlusion and residual neck states were achieved in 6 and 4 aneurysms after surgery. There were no neurologic deficits within 3 months after surgery except for frontalis palsy and anosmia in each patient. The endoscopic ICGA system with dual imaging of visible light and indocyanine green fluorescence was very useful for assessing geometry of aneurysms and surrounding vessels before clipping and for evaluating completeness of clip position after clipping. Copyright © 2017 Elsevier Inc. All rights reserved.
Surgical device for supporting corneal suturing
NASA Astrophysics Data System (ADS)
Ventura, Liliane; Oliveira, Gunter C. D.; De Groote, Jean-Jacques; Sousa, Sidney J. F.; Saia, Paula
2009-02-01
A system for ophthalmic surgery support has been developed in order to minimize the residual astigmatism due to the induced irregular shape of the cornea by corneal suture. The system projects 36 light spots, from LEDs, displayed in a precise circle at the lachrymal film of the examined cornea. The displacement, the size and deformation of the reflected image of these light spots are analyzed providing the keratometry and the circularity of the suture. Measurements in the range of 32D - 55D (up to 23D of astigmatism are possible to be obtained) and a self-calibration system has been designed in order to keep the system calibrated. Steel precision spheres have been submitted to the system and the results show 99% of correlation with the fabricant's nominal values. The system has been tested in 13 persons in order to evaluate its clinical applicability and has been compared to a commercial keratometer Topcon OM-4. The correlation factors are 0,92 for the astigmatism and 0.99 for the associated axis. The system indicates that the surgeon should achieve circularity >=98% in order to do not induce astigmatisms over 3D.
NASA Astrophysics Data System (ADS)
Venugopal, Vivek; Park, Minho; Ashitate, Yoshitomo; Neacsu, Florin; Kettenring, Frank; Frangioni, John V.; Gangadharan, Sidhu P.; Gioux, Sylvain
2013-12-01
We report the design, characterization, and validation of an optimized simultaneous color and near-infrared (NIR) fluorescence rigid endoscopic imaging system for minimally invasive surgery. This system is optimized for illumination and collection of NIR wavelengths allowing the simultaneous acquisition of both color and NIR fluorescence at frame rates higher than 6.8 fps with high sensitivity. The system employs a custom 10-mm diameter rigid endoscope optimized for NIR transmission. A dual-channel light source compatible with the constraints of an endoscope was built and includes a plasma source for white light illumination and NIR laser diodes for fluorescence excitation. A prism-based 2-CCD camera was customized for simultaneous color and NIR detection with a highly efficient filtration scheme for fluorescence imaging of both 700- and 800-nm emission dyes. The performance characterization studies indicate that the endoscope can efficiently detect fluorescence signal from both indocyanine green and methylene blue in dimethyl sulfoxide at the concentrations of 100 to 185 nM depending on the background optical properties. Finally, we performed the validation of this imaging system in vivo during a minimally invasive procedure for thoracic sentinel lymph node mapping in a porcine model.
Schlager, Daniel; Maas, Moritz; Hein, Simon; Adams, Fabian; Schoenthaler, Martin; Wetterauer, Ulrich; Diemer, Thorsten; Weidner, Wolfgang; Miernik, Arkadiusz
2016-08-01
The most common pathologies of the seminal tract are persistent hematospermia, seminal vesicle stones, and seminal duct obstruction. Endoscopic diagnostic work-up of the seminal tract is impeded by complex anatomy and lack of technical equipment. To date, there is no standardized endoscopic approach. The purpose of this study was to investigate the applicability and feasibility of a flexible microoptical device for atraumatic endoscopy of the seminal tract in a male human cadaver. The transurethral endoscopic examination was performed on a male cadaver. No premortal interventions or diseases of the genitourinary tract had been reported. The seminal orifice was identified via cystoscopy and accessed by the Seldinger technique using a hydrophilic guidewire and ureteral catheter. Retrograde endoscopic inspection of the distal seminal tract was performed using a miniaturized flexible endoscope. An antegrade endoscopic inspection of the seminal tract was carried out via high scrotal access to the vas deferens. Structures of the seminal tract, such as the ejaculatory duct, seminal vesicles, and distal portion of the ductus deferentes, were visualized using the miniaturized endoscope. Image quality allowed identification of anatomical structures and characterization of tissue properties. The technical limitations we observed involved the system's maneuverability. Initial results of this novel endoscopic approach to the seminal tract using a flexible microoptical system are encouraging. However, considerable anatomical limitations of the targeted organs necessitate further refinements of the technical equipment. This approach might improve diagnostics and treatment of genitourinary diseases. Future surgical techniques may include intraseminal laser therapy or endoocclusion to monitor fertility in men.
Da Vinci Xi Robot-Assisted Penetrating Keratoplasty.
Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan
2017-06-01
This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5-61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use.
Su, Chih-Ying; Chuang, Hui-Ching; Tsai, Shang-Shyue; Chiu, Jeng-Fen
2005-03-01
In treating early glottic carcinomas, the outcomes of endoscopic laser cordectomy have been proven to be valuable in local control, survival, and vocal function preservation. In some extended cases, however, laser cordectomy may leave patients with poor vocal function because of vocal fold deficit. This work assesses the vocal outcome of medialization laryngoplasty with bipedicled strap muscle transposition for vocal fold deficit resulting from laser cordectomy in early glottic cancer patients. A prospective clinical series. Thirteen early glottic cancer patients who had vocal fold deficit caused by previous laser cordectomy underwent medialization laryngoplasty with bipedicled strap muscle transposition. The thyroid lamina on the cordectomy side was paramedially separated. The inner perichondrium was circumspectly raised from the overlying thyroid cartilage. After separating the thyrohyoid and cricothyroid membranes, the lamina was retracted laterally. A bipedicled strap muscle flap was then transposed into the area between the lamina and the paraglottic soft tissue. The thyroid cartilages were carefully sutured back in position. All patients received pre- and postoperative voice assessments comprising laryngostroboscopy and vocal function studies. Vocal enhancement was present in 92% (12/13) of patients after medialization laryngoplasty with strap muscle transposition. The glottal closure and maximal phonation time were noticeably improved by surgery. No dyspnea or other significant complications were observed in any patients. The outcomes show that bipedicled strap muscle transposition is a prosthesis-free, safe, and valuable laryngoplastic technique for correcting glottal incompetence caused by endoscopic laser cordectomy in early glottic cancer patients.
Foreign bodies in the urinary bladder and their management: a Pakistani experience.
Mannan, A; Anwar, S; Qayyum, A; Tasneem, R A
2011-01-01
This was a retrospective study conducted to assess the nature, presentation, mode of insertion, diagnosis and management of foreign bodies in the urinary bladder. Between January 1998 and December 2007, 20 patients with foreign bodies in their urinary bladder were treated at our centre. The records of these patients were reviewed and analysed for their symptoms, mode of insertion, diagnosis, management and complications. A total of 20 foreign bodies were recovered from the urinary bladders during the study period. These included JJ stents with calculi, intrauterine contraceptive devices with stones, a rubber stick, ribbon gauze, encrusted pieces of Foley catheter, proline thread with calculus, a suture needle, broken cold knives, the ceramic beak of a paediatric resectoscope, a knotted suprapubic tube, a hair clip, a nail, an electrical wire and a hairpin. The common presenting features were dysuria and haematuria. The diagnosis was established radiologically in most of the cases. The circumstances of insertion were variable; iatrogenic in 16 (80.0 percent) cases, sexual stimulation in two (10.0 percent), accidental insertion by a child in one (5.0 percent) and physical torture in one (5.0 percent). 17 (85.0 percent) foreign bodies were recovered endoscopically, and cystolithotomy was required in three (15.0 percent) patients. The instances of foreign bodies in the urinary bladder are uncommon. A diagnosis is usually made radiologically. Iatrogenic foreign bodies were found to be the most frequent type of insertion encountered. Endoscopic retrieval is usually successful, with minimal morbidity.
Kumamoto, Etsuko; Takahashi, Akihiro; Matsuoka, Yuichiro; Morita, Yoshinori; Kutsumi, Hiromu; Azuma, Takeshi; Kuroda, Kagayaki
2013-01-01
The MR-endoscope system can perform magnetic resonance (MR) imaging during endoscopy and show the images obtained by using endoscope and MR. The MR-endoscope system can acquire a high-spatial resolution MR image with an intraluminal radiofrequency (RF) coil, and the navigation system shows the scope's location and orientation inside the human body and indicates MR images with a scope view. In order to conveniently perform an endoscopy and MR procedure, the design of the user interface is very important because it provides useful information. In this study, we propose a navigation system using a wireless accelerometer-based controller with Bluetooth technology and a navigation technique to set the intraluminal RF coil using the navigation system. The feasibility of using this wireless controller in the MR shield room was validated via phantom examinations of the influence on MR procedures and navigation accuracy. In vitro examinations using an isolated porcine stomach demonstrated the effectiveness of the navigation technique using a wireless remote-control device.
3D endoscopic imaging using structured illumination technique (Conference Presentation)
NASA Astrophysics Data System (ADS)
Le, Hanh N. D.; Nguyen, Hieu; Wang, Zhaoyang; Kang, Jin U.
2017-02-01
Surgeons have been increasingly relying on minimally invasive surgical guidance techniques not only to reduce surgical trauma but also to achieve accurate and objective surgical risk evaluations. A typical minimally invasive surgical guidance system provides visual assistance in two-dimensional anatomy and pathology of internal organ within a limited field of view. In this work, we propose and implement a structure illumination endoscope to provide a simple, inexpensive 3D endoscopic imaging to conduct high resolution 3D imagery for use in surgical guidance system. The system is calibrated and validated for quantitative depth measurement in both calibrated target and human subject. The system exhibits a depth of field of 20 mm, depth resolution of 0.2mm and a relative accuracy of 0.1%. The demonstrated setup affirms the feasibility of using the structured illumination endoscope for depth quantization and assisting medical diagnostic assessments
Nagatani, T; Saito, K; Yoshida, J
2001-09-01
A sphenoid sinus mucocele extending into the middle cranial fossa and the pterygomaxillary fissure was decompressed using an endoscope in combination with a navigation system. A 59-year-old woman was admitted with a 3 month history of retro-ocular pain and right sided exophthalmos. To evaluate the cystic lesion, a fibreoptic endoscope was inserted into the cyst through an erosive defect in the temporal bone. The histopathological appearance of cyst wall tissue confirmed the diagnosis of mucocele. After 4 months, the mucocele had refilled and the exophthalmos had recurred. At reoperation, the cyst was fenestrated using a rigid endoscope combined with a navigation system inserted via a sublabial transmaxillary approach. The proper site of cyst fenestration was precisely determined using the navigation system, permitting complete evacuation of this large lesion with minimal invasiveness. Copyright 2001 Harcourt Publishers Ltd.
Kessler, M A; Lichtenberg, S; Habermeyer, P
2003-10-01
Tendon retraction and fatty degeneration is a major problem in repair of massive rotator cuff tears. Especially in the transosseous refixation technique, a tension-free refixation cannot be obtained in all cases. The purpose of this prospective study was to evaluate the postoperative results using a new tension-free reinsertion technique with a Corkscrew suture anchor system. Thirty patients (25 males, 5 females) with complete one and two tendon tears underwent open rotator cuff repair (rupture of one tendon: n=14, 47%). The torn tendons were mobilized and reinserted medially to reduce tension. Medialization was achieved by inserting tendon near the osteochondral border in a bony trough. The number of implanted suture anchors ranged from 2 to 6 (mean: 3.56). The mean age was 56 years (39-68 years) with a follow-up of 24 months (17-33 months). In one patient physical and sonographic examination showed a complete and in two patients a partial rerupture. A temporarily frozen shoulder occurred in two cases. No infection or rejection response was seen. In no case was revision surgery necessary. No displacement or loosening of the Corkscrew anchors was noticed. The constant score improved from 45 points preoperatively to 85 points at the time of follow-up (mean). The Corkscrew suture anchor system in combination with the new suture technique offers the possibility of a stable reinsertion even in reduced calcified bone structure. This facilitates good conditions for stable fibroblastic healing. Our midterm results show good osseous union combined with a low rerupture rate.
Senior, Brent A
2008-01-01
Endoscopic skull base surgery has undergone rapid advancement in the past decade moving from pituitary surgery to suprasellar lesions and now to a myriad of lesions extending from the cribriform plate to C2 and laterally out to the infratemporal fossa and petrous apex. Evolution of several technological advances as well as advances in understanding of endoscopic anatomy and the development of surgical techniques both in resection and reconstruction have fostered this capability. Management of benign disease via endoscopic methods is largely accepted now but more data is needed before the controversy on the role of endoscopic management of malignant disease is decided. Continued advances in surgical technique, navigation systems, endoscopic imaging technology, and robotics assure continued brisk evolution in this expanding field. PMID:19434274
Bio-inspired ``jigsaw''-like interlocking sutures: Modeling, optimization, 3D printing and testing
NASA Astrophysics Data System (ADS)
Malik, I. A.; Mirkhalaf, M.; Barthelat, F.
2017-05-01
Structural biological materials such as bone, teeth or mollusk shells draw their remarkable performance from a sophisticated interplay of architectures and weak interfaces. Pushed to the extreme, this concept leads to sutured materials, which contain thin lines with complex geometries. Sutured materials are prominent in nature, and have recently served as bioinspiration for toughened ceramics and glasses. Sutures can generate large deformations, toughness and damping in otherwise all brittle systems and materials. In this study we examine the design and optimization of sutures with a jigsaw puzzle-like geometry, focusing on the non-linear traction behavior generated by the frictional pullout of the jigsaw tabs. We present analytical models which accurately predict the entire pullout response. Pullout strength and energy absorption increase with higher interlocking angles and for higher coefficients of friction, but the associated high stresses in the solid may fracture the tabs. Systematic optimization reveals a counter-intuitive result: the best pullout performance is achieved with interfaces with low coefficient of friction and high interlocking angle. We finally use 3D printing and mechanical testing to verify the accuracy of the models and of the optimization. The models and guidelines we present here can be extended to other types of geometries and sutured materials subjected to other loading/boundary conditions. The nonlinear responses of sutures are particularly attractive to augment the properties and functionalities of inherently brittle materials such as ceramics and glasses.
Bae, Sam Y; Korniski, Ronald J; Shearn, Michael; Manohara, Harish M; Shahinian, Hrayr
2017-01-01
High-resolution three-dimensional (3-D) imaging (stereo imaging) by endoscopes in minimally invasive surgery, especially in space-constrained applications such as brain surgery, is one of the most desired capabilities. Such capability exists at larger than 4-mm overall diameters. We report the development of a stereo imaging endoscope of 4-mm maximum diameter, called Multiangle, Rear-Viewing Endoscopic Tool (MARVEL) that uses a single-lens system with complementary multibandpass filter (CMBF) technology to achieve 3-D imaging. In addition, the system is endowed with the capability to pan from side-to-side over an angle of [Formula: see text], which is another unique aspect of MARVEL for such a class of endoscopes. The design and construction of a single-lens, CMBF aperture camera with integrated illumination to generate 3-D images, and the actuation mechanism built into it is summarized.
Endoscopic neurosurgery "around the corner" with a rigid endoscope. Technical note.
Hopf, N J
1999-03-01
Endoscopically "working around the corner" is presently restricted to the use of flexible endoscopes or an endoscope-assisted microneurosurgical (EAM) technique. In order to overcome the limitations of these solutions, endoscopic equipment and techniques were developed for "working around the corner" with rigid endoscopes. A steering insert with a 5 French working channel is capable of steering instruments around the corner by actively bending the guiding track and consecutively the instrument. A special fixation device enables strict axial rotation of the endoscope in the operating field. Endoscopic procedures "around the corner", including aqueductal stenting, pellucidotomy, third ventriculostomy and biopsy were performed in human cadavers. Special features of the used pediatric neuroendoscope system, i.e., reliable fixation, axial rotation, and controlled steering of instruments, increase the safety and reduce the surgical traumatization in selected cases, such as obstructive hydrocephalus due to a mass lesion in the posterior third ventricle, since endoscopic third ventriculostomy and biopsy can be performed through the same burr hole trephination. Limitations of this technique are given by the size of the foramen of Monro and the height of the third ventricle as well as by the bending angle of the instruments (40-50 degrees).
The Role of Direct and Visual Force Feedback in Suturing Using a 7-DOF Dual-Arm Teleoperated System.
Talasaz, Ali; Trejos, Ana Luisa; Patel, Rajni V
2017-01-01
The lack of haptic feedback in robotics-assisted surgery can result in tissue damage or accidental tool-tissue hits. This paper focuses on exploring the effect of haptic feedback via direct force reflection and visual presentation of force magnitudes on performance during suturing in robotics-assisted minimally invasive surgery (RAMIS). For this purpose, a haptics-enabled dual-arm master-slave teleoperation system capable of measuring tool-tissue interaction forces in all seven Degrees-of-Freedom (DOFs) was used. Two suturing tasks, tissue puncturing and knot-tightening, were chosen to assess user skills when suturing on phantom tissue. Sixteen subjects participated in the trials and their performance was evaluated from various points of view: force consistency, number of accidental hits with tissue, amount of tissue damage, quality of the suture knot, and the time required to accomplish the task. According to the results, visual force feedback was not very useful during the tissue puncturing task as different users needed different amounts of force depending on the penetration of the needle into the tissue. Direct force feedback, however, was more useful for this task to apply less force and to minimize the amount of damage to the tissue. Statistical results also reveal that both visual and direct force feedback were required for effective knot tightening: direct force feedback could reduce the number of accidental hits with the tissue and also the amount of tissue damage, while visual force feedback could help to securely tighten the suture knots and maintain force consistency among different trials/users. These results provide evidence of the importance of 7-DOF force reflection when performing complex tasks in a RAMIS setting.
Computer-aided decision support systems for endoscopy in the gastrointestinal tract: a review.
Liedlgruber, Michael; Uhl, Andreas
2011-01-01
Today, medical endoscopy is a widely used procedure to inspect the inner cavities of the human body. The advent of endoscopic imaging techniques-allowing the acquisition of images or videos-created the possibility for the development of the whole new branch of computer-aided decision support systems. Such systems aim at helping physicians to identify possibly malignant abnormalities more accurately. At the beginning of this paper, we give a brief introduction to the history of endoscopy, followed by introducing the main types of endoscopes which emerged so far (flexible endoscope, wireless capsule endoscope, and confocal laser endomicroscope). We then give a brief introduction to computer-aided decision support systems specifically targeted at endoscopy in the gastrointestinal tract. Then we present general facts and figures concerning computer-aided decision support systems and summarize work specifically targeted at computer-aided decision support in the gastrointestinal tract. This summary is followed by a discussion of some common issues concerning the approaches reviewed and suggestions of possible ways to resolve them.
Volume holographic reflection endoscope for in-vivo ovarian cancer clinical studies
NASA Astrophysics Data System (ADS)
Howlett, I. D.; Gordon, M.; Brownlee, J. W.; Barton, J. K.; Kostuk, R. K.
2014-03-01
We present the design for an endoscopic system capable of imaging tissues of the ovary at two selected imaging depths simultaneously. The method utilizes a multiplexed volume hologram to select wavefronts from different depths within the tissue. It is the first demonstration of an endoscopic volume holographic imaging system. The endoscope uses both gradient index (GRIN) optical components and off the shelf singlet lenses to relay an image from the distal tip to the proximal end. The endoscope has a minimum diameter of 3.75 mm. The system length is 30 cm which is connected to a handle that includes the holographic components and optics that relay the image to a camera. Preliminary evaluation of the endoscope was performed with tissue phantoms and calibrated targets, which shows lateral resolution ≍ 4 μm at an operating wavelength of 660 nm. The hologram is recorded in phenanthraquinone doped poly methacrylate and is designed to produce images from two tissue depths. One image is obtained at the tissue surface and the second 70 μm below the surface. This method requires no mechanical scanning and acquires an image at the camera frame rate. The preliminary ex-vivo results show good correlation with histology sections of the same tissue sections.
NASA Technical Reports Server (NTRS)
2000-01-01
The Automated Endoscopic System for Optimal Positioning, or AESOP, was developed by Computer Motion, Inc. under a SBIR contract from the Jet Propulsion Lab. AESOP is a robotic endoscopic positioning system used to control the motion of a camera during endoscopic surgery. The camera, which is mounted at the end of a robotic arm, previously had to be held in place by the surgical staff. With AESOP the robotic arm can make more precise and consistent movements. AESOP is also voice controlled by the surgeon. It is hoped that this technology can be used in space repair missions which require precision beyond human dexterity. A new generation of the same technology entitled the ZEUS Robotic Surgical System can make endoscopic procedures even more successful. ZEUS allows the surgeon control various instruments in its robotic arms, allowing for the precision the procedure requires.
Extraction of endoscopic images for biomedical figure classification
NASA Astrophysics Data System (ADS)
Xue, Zhiyun; You, Daekeun; Chachra, Suchet; Antani, Sameer; Long, L. R.; Demner-Fushman, Dina; Thoma, George R.
2015-03-01
Modality filtering is an important feature in biomedical image searching systems and may significantly improve the retrieval performance of the system. This paper presents a new method for extracting endoscopic image figures from photograph images in biomedical literature, which are found to have highly diverse content and large variability in appearance. Our proposed method consists of three main stages: tissue image extraction, endoscopic image candidate extraction, and ophthalmic image filtering. For tissue image extraction we use image patch level clustering and MRF relabeling to detect images containing skin/tissue regions. Next, we find candidate endoscopic images by exploiting the round shape characteristics that commonly appear in these images. However, this step needs to compensate for images where endoscopic regions are not entirely round. In the third step we filter out the ophthalmic images which have shape characteristics very similar to the endoscopic images. We do this by using text information, specifically, anatomy terms, extracted from the figure caption. We tested and evaluated our method on a dataset of 115,370 photograph figures, and achieved promising precision and recall rates of 87% and 84%, respectively.
Wentink, M; Jakimowicz, J J; Vos, L M; Meijer, D W; Wieringa, P A
2002-08-01
Compared to open surgery, minimally invasive surgery (MIS) relies heavily on advanced technology, such as endoscopic viewing systems and innovative instruments. The aim of the study was to objectively compare three technologically advanced laparoscopic viewing systems with the standard viewing system currently used in most Dutch hospitals. We evaluated the following advanced laparoscopic viewing systems: a Thin Film Transistor (TFT) display, a stereo endoscope, and an image projection display. The standard viewing system was comprised of a monocular endoscope and a high-resolution monitor. Task completion time served as the measure of performance. Eight surgeons with laparoscopic experience participated in the experiment. The average task time was significantly greater (p <0.05) with the stereo viewing system than with the standard viewing system. The average task times with the TFT display and the image projection display did not differ significantly from the standard viewing system. Although the stereo viewing system promises improved depth perception and the TFT and image projection displays are supposed to improve hand-eye coordination, none of these systems provided better task performance than the standard viewing system in this pelvi-trainer experiment.
NASA Astrophysics Data System (ADS)
Efendiev, V. U.; Alsov, S. A.; Ruzmatov, T. M.; Mikheenko, I. L.; Chernyavsky, A. M.; Malakhov, E. S.
2015-11-01
A new technology - a thoracoscopic coronary bypass grafting with the use of Da Vinci robotic system in Russia is represented by the experience of NRICP. The technology was introduced in Russia in 2011. Overall, one hundred endoscopic coronary artery bypass procedures were performed. We have compared and analyzed results of coronary artery stenting vs minimally invasive coronary artery bypass grafting. According to the results, totally endoscopic coronary artery bypass grafting has several advantages over alternative treatment strategies.
Park, Ji Soon; McGarry, Michelle H; Campbell, Sean T; Seo, Hyuk Jun; Lee, Yeon Soo; Kim, Sae Hoon; Lee, Thay Q; Oh, Joo Han
2015-09-01
Transosseous-equivalent (TOE) rotator cuff repair can increase contact area and contact pressure between the repaired cuff tendon and bony footprint and can show higher ultimate loads to failure and smaller gap formation compared with other repair techniques. However, it has been suggested that medial rotator cuff failure after TOE repair may result from increased bridging suture tension. To determine optimum bridging suture tension in TOE repair by evaluating footprint contact and construct failure characteristics at different tensions. Controlled laboratory study. A total of 18 fresh-frozen cadaveric shoulders, randomly divided into 3 groups, were constructed with a TOE configuration using the same medial suture anchor and placing a Tekscan sensing pad between the repaired rotator cuff tendon and footprint. Nine of the 18 shoulders were used to measure footprint contact characteristics. With use of the Tekscan measurement system, the contact pressure and area between the rotator cuff tendon and greater tuberosity were quantified for bridging suture tensions of 60, 90, and 120 N with glenohumeral abduction angles of 0° and 30° and humeral rotation angles of 30° (internal), 0°, and 30° (external). TOE constructs of all 18 shoulders then underwent construct failure testing (cyclic loading and load to failure) to determine the yield load, ultimate load, stiffness, hysteresis, strain, and failure mode at 60 and 120 N of tension. As bridging suture tension increased, contact force, contact pressure, and peak pressure increased significantly at all positions (P < .05 for all). Regarding contact area, no significant differences were found between 90 and 120 N at all positions, although there were significant differences between 60 and 90 N. The construct failure test demonstrated no significant differences in any parameters according to various tensions (P > .05 for all). Increasing bridging suture tension to over 90 N did not improve contact area but did increase contact force and pressure. Bridging suture tension did not significantly affect ultimate failure loads. Considering the risks of overtensioning bridging sutures, it may be clinically more beneficial to keep bridging suture tension below 90 N. © 2015 The Author(s).
Combined metopic and unilateral coronal synostoses: a phenotypic conundrum.
Sauerhammer, Tina M; Patel, Kamlesh; Oh, Albert K; Proctor, Mark R; Mulliken, John B; Rogers, Gary F
2014-03-01
Most types of craniosynostosis cause predictable changes in cranial shape. However, the phenotype of combined metopic and unilateral coronal synostoses is anomalous. The purpose of this observational study was to better clarify the clinical and radiographic features of this rare entity. A retrospective review of a craniofacial database was performed. Patients with combined metopic and unilateral coronal synostoses were included in this study. Data collected included demographic information, physical and radiographic findings, genetic evaluation, treatment, and operative outcomes. Of 687 patients treated between 1989 and 2010, only 3 patients had combined metopic and unilateral coronal synostoses. All patients were diagnosed through computed tomography on the first day of life. Phenotypic features included the following: (1) narrowed forehead with a prominent midline ridge, (2) severe bilateral brow retrusion with an acute indentation on the side of the patient coronal suture, (3) facial and nasal angulation similar to isolated unilateral coronal synostosis, and (4) anterior displacement of the ear on the fused side. In addition, the cranial vertex was deviated toward the side of the open coronal suture. Two patients had a head circumference below the 25th percentile; 2 of the 3 had a TWIST gene mutation consistent with Saethre-Chotzen syndrome. One patient was managed through fronto-orbital advancement and required a revision. The other 2 patients had early endoscopic release, followed by postoperative helmet therapy; one improved but still required open cranial remodeling. The other has near-normal phenotype, and no further surgery is planned. Combined metopic and unilateral coronal synostoses present a rare and unusual phenotype. Although early intervention improves the deformity, revisional procedures are usually required.
Maker, Ajay V
2013-12-01
The majority of gastrointestinal stromal tumors (GISTs) are located in the stomach. With greater experience in minimally invasive oncologic surgery, gastric GISTs are being increasingly approached laparoscopically. Posterior proximally located endophytic gastric GISTs can be challenging to approach laparoscopically and excise with an adequate margin without an anterior or posterior gastrotomy, or intragastric ports. The gastrocolic and gastrosplenic ligaments are divided up to the gastroesophageal junction. The left lateral segment of the liver is mobilized to allow anterior reflection of the gastric fundus. Intraoperative ultrasound confirms the location and extent of the tumor base. Upper endoscopy is performed to trans-illuminate, confirm tumor location, and search for multifocality. Traction sutures are placed around the tumor to distract endophytic lesions. With organo-axial rotation of the stomach using the stay sutures, an endoGIA stapler approximates the posterior fundic wall under the base of the lesion ensuring an adequate margin and eliminating the risk of gastric spillage. Appropriate stapler placement and margins are assisted real-time endoscopically with picture-in-picture. The stapleline is tested for leaks and inspected for hemostasis laparoendoscopically. Complete resection of GISTs with adequate margins is performed with sound oncologic principles and demonstrated in tumors of varying sizes and locations in the proximal posterior stomach, including near the GE junction. This video demonstrates a simple laparoendoscopic technique to quickly localize even small tumors, visually confirm adequate margins, and excise gastric GISTs without spillage or gastrotomy that are located in a typically difficult area of the stomach to approach laparoscopically.
Sardelli, Paolo; Barrettara, Barbara; Cisternino, Marco Luigi; Napoli, Gaetano; Lacitignola, Angelo; Quitadamo, Stefania
2012-03-01
One of the fundamental steps in an anatomical pulmonary resection is the main and lobar bronchus suture. Nowadays, two different types of staplers are on the market: the linear TA stapler for open surgery (Tyco Healthcare Group LP, Norwalk, CT, USA), which is based on a 'guillotine' mechanism, sewing, but not cutting the bronchus, and the endoscopic linear stapler which both cuts and sews. This study aimed to fill the void in the use of an instrument used to staple and cut at the same time in 'open' thoracic surgery, eliminating the need for a scalpel: the curved cutter stapler (Contour Curved Cutter Stapler; Ethicon Endo-Surgery, Inc., Cincinnati, OH, USA). Between May 2009 and March 2011, the Contour Curved Stapler (Ethicon) was used for the bronchus in 139 cases of non-small cell lung carcinoma (NSCLC)-29 females and 110 males ranging between 48 and 85 years (average 71.1)-and comprising 115 lobectomies (8 bilobectomies) and 24 pneumonectomies (8 on the right lung, 16 on the left lung). All patients underwent a bronchoscopic check-up 30 days after they were discharged: in all cases, the bronchial stump was clearly within normal limits. No cases of bronchopleural fistulas were observed in the 139 patients. On the basis of this study, the curved cutter stapler showed to be a satisfactory device for securing the bronchus during an anatomic resection (whether lobar or main), in 'open' thoracic surgery. However, even though there were no cases of fistula, we consider that our data is still too limited to be statistically significant.
Schweykart, N; Reinhard, T; Engelhardt, S; Sundmacher, R
1999-06-01
Ultrasound biomicroscopy (UBM) allows to determine the haptic position of posterior chamber lenses (PCL) in relation to adjacent structures. In transsclerally sutured PCLs, the comparison between intraoperatively endoscopically and postoperatively localized haptic positions via UBM showed a correspondence of only 81%. The different localisation of 19% of the examined haptic positions was explained with postoperative dislocation without any proof for this assumption. The purpose of this study therefore was the correlation of UBM results with simultaneously determined haptic positions via gonioscopy in aniridia after black diaphragm PCL implantation. The haptic positions of black diaphragm PCL implants in 20 patients with congenital and 13 patients with traumatic aniridia were determined via UBM (50-MHz-probe) and gonioscopy 44.4 (6-75) months postoperatively. 39/66 haptic positions could be localized in gonioscopy as well as in UBM. 38 haptics (97.4%) showed the same position in both examination techniques. Determination of the haptic position through one of the two examination techniques was impossible in 27/66 haptics (11 haptics in gonioscopy, 16 haptics in UBM). Reasons for this were primarily haptic position behind iris remnants and corneal opacities in gonioscopy and scarring of the ciliary body in UBM. The validity of UBM in localization of PCLs was confirmed gonioscopically, which also confirms our prior assumption of postoperative displacement of IOL-haptics after transscleral suturing in about 20% of cases. Scarring of the ciliary body was the most important obstacle in the determination of PCL haptic positions in relation to adjacent structures.
Implemented a wireless communication system for VGA capsule endoscope.
Moon, Yeon-Kwan; Lee, Jyung Hyun; Park, Hee-Joon; Cho, Jin-Ho; Choi, Hyun-Chul
2014-01-01
Recently, several medical devices that use wireless communication are under development. In this paper, the small size frequency shift keying (FSK) transmitter and a monofilar antenna for the capsule endoscope, enabling the medical device to transmit VGA-size images of the intestine. To verify the functionality of the proposed wireless communication system, computer simulations and animal experiments were performed with the implemented capsule endoscope that includes the proposed wireless communication system. Several fundamental experiments are carried out using the implemented transmitter and antenna, and animal in-vivo experiments were performed to verify VGA image transmission.
Lee, Sang Heun; Lee, Jaebok; Yoon, Young Joong; Park, Sangbok; Cheon, Changyul; Kim, Kihyun; Nam, Sangwook
2011-06-01
This paper presents the design of a wideband spiral antenna for ingestible capsule endoscope systems and a comparison between the experimental results in a human phantom and a pig under general anesthesia. As wireless capsule endoscope systems transmit real-time internal biological image data at a high resolution to external receivers and because they operate in the human body, a small wideband antenna is required. To incorporate these properties, a thick-arm spiral structure is applied to the designed antenna. To make practical and efficient use of antennas inside the human body, which is composed of a high dielectric and lossy material, the resonance characteristics and radiation patterns were evaluated through a measurement setup using a liquid human phantom. The total height of the designed antenna is 5 mm and the diameter is 10 mm. The fractional bandwidth of the fabricated antenna is about 21% with a voltage standing-wave ratio of less than 2, and it has an isotropic radiation pattern. These characteristics are suitable for wideband capsule endoscope systems. Moreover, the received power level was measured using the proposed antenna, a circular polarized receiver antenna, and a pig under general anesthesia. Finally, endoscopic capsule images in the stomach and large intestine were captured using an on-off keying transceiver system.
Design of a modified endoscope illuminator for spectral imaging of colorectal tissues
NASA Astrophysics Data System (ADS)
Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.
2017-02-01
The gold standard for locating colonic polyps is a white light endoscope in a colonoscopy, however, polyps smaller than 5 mm can be easily missed. Modified procedures such as narrow band imaging have shown only marginal increases in detection rates. Spectral imaging is a potential solution to improve the sensitivity and specificity of colonoscopies by providing the ability to distinguish molecular fluorescence differences in tissues. The goal of this work is to implement a spectral endoscopic light source to acquire spectral image data of colorectal tissues. A beta-version endoscope light source was developed, by retrofitting a white light endoscope light source (Olympus, CLK-4) with 16 narrow band LEDs. This redesigned, beta-prototype uses high-power LEDs with a minimum output of 500 mW to provide sufficient spectral output (0.5 mW) through the endoscope. A mounting apparatus was designed to provide sufficient heat dissipation. Here, we report recent results of our tests to characterize the intensity output through the light source and endoscope to determine the flat spectral output for imaging and intensity losses through the endoscope. We also report preliminary spectral imaging data from transverse pig colon that demonstrates the ability to result in working practical spectral data. Preliminary results of this revised prototype spectral endoscope system demonstrate that there is sufficient power to allow the imaging process to continue and potentially determine spectral differences in cancerous and normal tissue from imaging ex vivo pairs. Future work will focus on building a spectral library for the colorectal region and refining the user interface the system for in vivo use.
Okpara-Hofmann, J; Knoll, M; Dürr, M; Schmitt, B; Borneff-Lipp, M
2005-04-01
This study compared the effectiveness of sterilizing four types of endoscope using different models of the Sterrad system (Sterrad 50, 100, 100S and 200). Sterilization levels meeting international requirements were attained in all cases with carriers inoculated with Geobacillus stearothermophilus spores. The endoscopes were tested in half cycles ('overkill'). This is the first study to compare the Sterrad models marketed to date in terms of effective sterilization of endoscopes with narrow lumens.
Zanatta, Alysson; Sousa, Jânio S; Machado, Ricardo L; Polcheira, Paulo A
2015-01-01
To demonstrate the technique of laparoscopic discoid anterior rectal wall resection using a circular stapler, feasible in the case of rectosigmoid endometriosis lesions measuring ≤ 3 cm. Case report (Canadian Task Force classification III). Private practice hospital in São Paulo, Brazil. Thirty-four-year-old woman with pelvic deep endometriosis including a 2-cm lesion in the rectosigmoid situated 11 cm proximally to the anal border. She had chronic pelvic pain, dysmenorrhea, dyspareunia, and constipation. She had undergone no previous surgical procedures. Standard 4-puncture laparoscopy was performed, and all visible endometriosis lesions were first removed before proceeding to rectal resection. The avascular rectovaginal space was identified, and the rectosigmoid was mobilized cranially, releasing the vagina and increasing the final distance of the bowel anastomosis to the anal border. The rectosigmoid nodule was isolated in its entire circumference and remained restricted to the anterior wall of the bowel. It was then transfixed using a 2-0 polyglycolic suture, with the healthy proximal and distal limits of the bowel included in the suture. A 33-cm endoscopic circular stapler was introduced via the anus up to the distal limit of the lesion and opened inside the bowel lumen. By pulling the edges of the suture, the rectosigmoid nodule was introduced inside of the circular stapler. It was fired to resect the anterior rectal wall, and the anastomosis was situated at the anterior and lateral walls of the bowel. Integrity of the bowel was checked via infusion of saline solution with methylene blue dye. Gynecologic surgeons performed all of the procedures. Bowel resection took 20 minutes, and the entire surgical procedure lasted 120 minutes. The patient was discharged after 48 hours. There were no intercurrent events, either early or late postoperatively. The patient was symptom-free at 2 years of follow-up. Laparoscopic discoid excision of an anterior rectal nodule using the circular stapler is an effective option for treating selected cases of rectosigmoid endometriosis. The technique might be reproducible by gynecologic surgeons after proper training. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.
Laser-assisted skin closure at 1.32 microns: the use of a software-driven medical laser system
NASA Astrophysics Data System (ADS)
Dew, Douglas K.; Hsu, Tung M.; Hsu, Long S.; Halpern, Steven J.; Michaels, Charles E.
1991-06-01
This study investigated the use of a computerized 1 .3 micron Nd:YAG laser to seal approximated wound edges in pig skin. The medical laser system used was the DLS Type 1 , 1 .32 micron Nd:YAG laser (Laser Surgery Software, Inc.). The purpose of this study was to evaluate the effectiveness of laser assisted skin closure using the DLS YAG laser in a large animal model. Effectiveness was judged on the basis of wound dehiscence, infection, unusual healing result and consistency of results. Comparative cosmetic result was also evaluated. In this study, the DLS YAG laser was used to close scalpel-induced, full-thickness wounds. The pig model was chosen for its many integumentary similarities to man. Controls included scalpel-induced wounds closed using suture, staple and some with norepair. After adequate anesthesia was achieved, the dorsum of Yucutan pigs (approximately 75- 100 pounds) each was clipped with animal hair clippers from the shoulder area to the hind legs. The area was then shaved with a razor blade, avoiding any inadvertent cuts or abrasions of the skin. The dorsum was divided into four rows of four parallel incisions made by a #15 scalpel blade. Full-thickness incisions, 9 cm long, were placed over the dorsum of the pigs and then closed either with one loosely approximating Prolene" suture (the "no repair' group), multiple interrupted 6-0 nylon sutures, staples or laser. The experimental tissue sealing group consisted of 1 69 laser assisted closures on 1 3 pigs. Sutured control wounds were closed with 6-0 nylon, full thickness, simple, interrupted sutures. Eight sutures were placed 1 cm apart along the 9 cm incision. Stapled control wounds were approximated using two evenly spaced 3-0 VicryP' sub-dermal sutures and the dermis closed using Proximate' skin staples. Eight staples were placed 1 cm apart along the 9 cm incision. The no-repair incisions were grossly approximated using a single 2-0 Prolene full thickness, simple, interrupted suture located at the center of the 9 cm incision. Experimental wounds were approximated using two evenly spaced subdermal 3.0 Vicryl' sutures and the dermis closed by laser sealing using the DLS YAG laser. Wounds were examined daily for the first seven days and followed for up to 20 months postoperatively. To facilitate wound edge approximation, surgical tape that is relatively transparent to 1.3 micron irradiation was used to hold the wound edges approximated while laser application occurred. Surgical tape was also applied to the "no-repair" suture and staple closures at the end of each procedure.
Liu Bejarano, Humberto
2011-01-01
Due to the poor agreement between endoscopy and histology, the gastric biopsy continues being the gold standard for the diagnosis of atrophic chronic gastritis. The Virtual chromoendoscopy system allows better observation of the gastric mucosa. Evaluate the agreement between the Kimura-Takemoto ´s endoscopic system classification and the histological system of OLGA (Operative for Link Assessment Gastritis), as well as to evaluate the application of the virtual chromoendoscopy. A prospective and longitudinal study of cohorts, 138 patients was include, using endoscopic system of atrophy by Kimura and Takemoto (K-T), with conventional optical and with the use of seventh filter of virtual chromoendoscopy ,then comparing with the histological findings of the OLGA pathology system, also were determinated injuries associated with respect to stage OLGA. The kappa index of agreement between conventional endoscopy and the system OLGA was 0.859 and with the system of virtual chromoendoscopy was 0.822, the preneoplasic and neoplastic gastric lesions were associate to stages III and IV of atrophy. The endoscopic and histological correlation with both systems isvery good, with or without the use of virtual chromoendoscopy. chronic atrophic gastritis, virtual chromoendoscopy, olga system, , kimuratakemoto system.
Multispectral tissue characterization for intestinal anastomosis optimization.
Cha, Jaepyeong; Shademan, Azad; Le, Hanh N D; Decker, Ryan; Kim, Peter C W; Kang, Jin U; Krieger, Axel
2015-10-01
Intestinal anastomosis is a surgical procedure that restores bowel continuity after surgical resection to treat intestinal malignancy, inflammation, or obstruction. Despite the routine nature of intestinal anastomosis procedures, the rate of complications is high. Standard visual inspection cannot distinguish the tissue subsurface and small changes in spectral characteristics of the tissue, so existing tissue anastomosis techniques that rely on human vision to guide suturing could lead to problems such as bleeding and leakage from suturing sites. We present a proof-of-concept study using a portable multispectral imaging (MSI) platform for tissue characterization and preoperative surgical planning in intestinal anastomosis. The platform is composed of a fiber ring light-guided MSI system coupled with polarizers and image analysis software. The system is tested on ex vivo porcine intestine tissue, and we demonstrate the feasibility of identifying optimal regions for suture placement.
Multispectral tissue characterization for intestinal anastomosis optimization
Cha, Jaepyeong; Shademan, Azad; Le, Hanh N. D.; Decker, Ryan; Kim, Peter C. W.; Kang, Jin U.; Krieger, Axel
2015-01-01
Abstract. Intestinal anastomosis is a surgical procedure that restores bowel continuity after surgical resection to treat intestinal malignancy, inflammation, or obstruction. Despite the routine nature of intestinal anastomosis procedures, the rate of complications is high. Standard visual inspection cannot distinguish the tissue subsurface and small changes in spectral characteristics of the tissue, so existing tissue anastomosis techniques that rely on human vision to guide suturing could lead to problems such as bleeding and leakage from suturing sites. We present a proof-of-concept study using a portable multispectral imaging (MSI) platform for tissue characterization and preoperative surgical planning in intestinal anastomosis. The platform is composed of a fiber ring light-guided MSI system coupled with polarizers and image analysis software. The system is tested on ex vivo porcine intestine tissue, and we demonstrate the feasibility of identifying optimal regions for suture placement. PMID:26440616
Da Vinci Xi Robot–Assisted Penetrating Keratoplasty
Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan
2017-01-01
Purpose This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Methods Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Results Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5–61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. Conclusions We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Translational Relevance Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use. PMID:28660096
Design of embedded endoscopic ultrasonic imaging system
NASA Astrophysics Data System (ADS)
Li, Ming; Zhou, Hao; Wen, Shijie; Chen, Xiodong; Yu, Daoyin
2008-12-01
Endoscopic ultrasonic imaging system is an important component in the endoscopic ultrasonography system (EUS). Through the ultrasonic probe, the characteristics of the fault histology features of digestive organs is detected by EUS, and then received by the reception circuit which making up of amplifying, gain compensation, filtering and A/D converter circuit, in the form of ultrasonic echo. Endoscopic ultrasonic imaging system is the back-end processing system of the EUS, with the function of receiving digital ultrasonic echo modulated by the digestive tract wall from the reception circuit, acquiring and showing the fault histology features in the form of image and characteristic data after digital signal processing, such as demodulation, etc. Traditional endoscopic ultrasonic imaging systems are mainly based on image acquisition and processing chips, which connecting to personal computer with USB2.0 circuit, with the faults of expensive, complicated structure, poor portability, and difficult to popularize. To against the shortcomings above, this paper presents the methods of digital signal acquisition and processing specially based on embedded technology with the core hardware structure of ARM and FPGA for substituting the traditional design with USB2.0 and personal computer. With built-in FIFO and dual-buffer, FPGA implement the ping-pong operation of data storage, simultaneously transferring the image data into ARM through the EBI bus by DMA function, which is controlled by ARM to carry out the purpose of high-speed transmission. The ARM system is being chosen to implement the responsibility of image display every time DMA transmission over and actualizing system control with the drivers and applications running on the embedded operating system Windows CE, which could provide a stable, safe and reliable running platform for the embedded device software. Profiting from the excellent graphical user interface (GUI) and good performance of Windows CE, we can not only clearly show 511×511 pixels ultrasonic echo images through application program, but also provide a simple and friendly operating interface with mouse and touch screen which is more convenient than the traditional endoscopic ultrasonic imaging system. Including core and peripheral circuits of FPGA and ARM, power network circuit and LCD display circuit, we designed the whole embedded system, achieving the desired purpose by implementing ultrasonic image display properly after the experimental verification, solving the problem of hugeness and complexity of the traditional endoscopic ultrasonic imaging system.
Okubo, Hirotaka; Kusano, Nozomu; Kinjo, Masaki; Kanaya, Fuminori
2015-01-01
In multi-strand suture methods consisting of several suture rows, the different length of core suture purchase between each suture row may affect the strength of repairs. We evaluated the influence of the different length of core suture purchase between each suture row on the strength of 6-strand tendon repairs. Rabbit flexor tendons were repaired by using a triple-looped suture technique in which the suture purchase length in each suture row was modified. Group 1, all lengths are 8-mm. Group 2, all lengths are 10-mm. Group 3, two are 10-mm and one is 8-mm. Group 4, one is 10-mm and two are 8-mm. The repaired tendons were subjected to load-to-failure test. The gap strength was significantly greater in Group 1 and Group 2 than in Group 3 and Group 4. This study demonstrates that maintaining equal core suture purchase lengths of each suture row increases the gap resistance.
The efficacy of a single continuous nylon suture for control of post keratoplasty astigmatism.
Van Meter, W
1996-01-01
PURPOSE: Post operative adjustment of a single continuous suture is an effective means of reducing post keratoplasty astigmatism. This study evaluates post keratoplasty keratometry following suture adjustment with an adjusted suture in place and after the suture is removed. METHODS: Average keratometric astigmatism was measured over 24 months time in 26 patients with an adjusted continuous suture and 24 patients with a continuous suture that was not adjusted. Average keratometry in 43 patients with an adjusted continuous suture was compared with 37 patients with combined continuous and interrupted sutures. Finally, suture out astigmatism in 19 adjusted patients was compared to six patients with no adjustment. RESULTS: There was an increase in average corneal astigmatism over two years of 2.2 diopters in the adjusted group and 1.7 diopters in the non-adjusted group with sutures in place. One year following surgery, average keratometry flattened from 47.5 to 42.9 diopters in the adjusted continuous group and from 47.0 to 46.0 diopters in the group with combined continuous and interrupted sutures. Following suture removal, average astigmatism in patients who had suture adjustment was 4.4 diopters +/- 2.5 diopters (range 1-10 diopters), and 6.01 diopters (range 4-7) in the non-adjusted group. CONCLUSIONS: Average post keratoplasty astigmatism increases after a continuous suture is adjusted but the increase is comparable to patients with acceptable astigmatism who do not require adjustment. More progressive corneal flattening over 12 months time is seen with a continuous suture than which combined sutures. Average suture out astigmatism was 4.0 diopters following suture adjustment, compared to an average of 8.4 diopters prior to adjustment. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 7A FIGURE 7B PMID:8981721
Monitoring blood-flow in the mouse cochlea using an endoscopic laser speckle contrast imaging system
Yu, Sunkon; Jung, Byungjo; Choi, Jin Sil
2018-01-01
Laser speckle contrast imaging (LSCI) enables continuous high-resolution assessment of microcirculation in real-time. We applied an endoscope to LSCI to measure cochlear blood-flow in an ischemia–reperfusion mouse model. We also explored whether using xenon light in combination with LSCI facilitates visualization of anatomical position. Based on a previous preliminary study, the appropriate wavelength for penetrating the thin bony cochlea was 830 nm. A 2.7-mm-diameter endoscope was used, as appropriate for the size of the mouse cochlea. Our endoscopic LSCI system was used to illuminate the right cochlea after dissection of the mouse. We observed changes in the speckle signals when we applied the endoscopic LSCI system to the ischemia-reperfusion mouse model. The anatomical structure of the mouse cochlea and surrounding structures were clearly visible using the xenon light. The speckle signal of the cochlea was scattered, with an intensity that varied between that of the stapes (with the lowest signal), the negative control, and the stapedial artery (with the highest signal), the positive control. In the cochlear ischemia–reperfusion mouse model, the speckle signal of the cochlea decreased during the ischemic phase, and increased during the reperfusion phase, clearly reflecting cochlear blood-flow. The endoscopic LSCI system generates high-resolution images in real-time, allowing visualization of blood-flow and its changes in the mouse cochlea. Anatomical structures were clearly matched using LSCI along with visible light. PMID:29489849
Kong, Tae Hoon; Yu, Sunkon; Jung, Byungjo; Choi, Jin Sil; Seo, Young Joon
2018-01-01
Laser speckle contrast imaging (LSCI) enables continuous high-resolution assessment of microcirculation in real-time. We applied an endoscope to LSCI to measure cochlear blood-flow in an ischemia-reperfusion mouse model. We also explored whether using xenon light in combination with LSCI facilitates visualization of anatomical position. Based on a previous preliminary study, the appropriate wavelength for penetrating the thin bony cochlea was 830 nm. A 2.7-mm-diameter endoscope was used, as appropriate for the size of the mouse cochlea. Our endoscopic LSCI system was used to illuminate the right cochlea after dissection of the mouse. We observed changes in the speckle signals when we applied the endoscopic LSCI system to the ischemia-reperfusion mouse model. The anatomical structure of the mouse cochlea and surrounding structures were clearly visible using the xenon light. The speckle signal of the cochlea was scattered, with an intensity that varied between that of the stapes (with the lowest signal), the negative control, and the stapedial artery (with the highest signal), the positive control. In the cochlear ischemia-reperfusion mouse model, the speckle signal of the cochlea decreased during the ischemic phase, and increased during the reperfusion phase, clearly reflecting cochlear blood-flow. The endoscopic LSCI system generates high-resolution images in real-time, allowing visualization of blood-flow and its changes in the mouse cochlea. Anatomical structures were clearly matched using LSCI along with visible light.
Suture Coding: A Novel Educational Guide for Suture Patterns.
Gaber, Mohamed; Abdel-Wahed, Ramadan
2015-01-01
This study aims to provide a helpful guide to perform tissue suturing successfully using suture coding-a method for identification of suture patterns and techniques by giving full information about the method of application of each pattern using numbers and symbols. Suture coding helps construct an infrastructure for surgical suture science. It facilitates the easy understanding and learning of suturing techniques and patterns as well as detects the relationship between the different patterns. Guide points are fixed on both edges of the wound to act as a guideline to help practice suture pattern techniques. The arrangement is fixed as 1-3-5-7 and a-c-e-g on one side (whether right or left) and as 2-4-6-8 and b-d-f-h on the other side. Needle placement must start from number 1 or letter "a" and continue to follow the code till the end of the stitching. Some rules are created to be adopted for the application of suture coding. A suture trainer containing guide points that simulate the coding process is used to facilitate the learning of the coding method. (120) Is the code of simple interrupted suture pattern; (ab210) is the code of vertical mattress suture pattern, and (013465)²/3 is the code of Cushing suture pattern. (0A1) Is suggested as a surgical suture language that gives the name and type of the suture pattern used to facilitate its identification. All suture patterns known in the world should start with (0), (A), or (1). There is a relationship between 2 or more surgical patterns according to their codes. It can be concluded that every suture pattern has its own code that helps in the identification of its type, structure, and method of application. Combination between numbers and symbols helps in the understanding of suture techniques easily without complication. There are specific relationships that can be identified between different suture patterns. Coding methods facilitate suture patterns learning process. The use of suture coding can be a good approach to the construction of an infrastructure of surgical suture science and the facilitation of the understanding and learning of suture pattern techniques. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Sattar, Syed A; Kibbee, Richard J; Tetro, Jason A; Rook, Tony A
2006-11-01
To evaluate the effectiveness of a high-level disinfection solution generated inside an endoscope processing system for decontaminating external and internal surfaces of experimentally contaminated heat-sensitive medical devices. The American Society for Testing and Materials Simulated-Use Test protocol (E1837-02), which incorporates a soil load in each inoculum, was used to evaluate the efficacy of the system when processing 4 common types of endoscopes contaminated separately with 5 types of nosocomial pathogens: Pseudomonas aeruginosa (ATCC 15442), spores of Clostridium difficile (ATCC 9689), a glutaraldehyde-resistant strain of Mycobacterium chelonae, a vancomycin-resistant strain of Enterococcus faecalis, and a methicillin-resistant strain of Staphylococcus aureus. Rinse solution samples from channels and from surfaces of the processed endoscopes were tested for any microbicidal residues. For all organisms tested, the baseline level of contamination of the endoscopes ranged from 5 log(10) to greater than 7 log(10) at each external surface site and internal channel. All tests showed reductions in viability of the test organisms to undetectable levels. All rinse solution samples from external and internal sites of the endoscopes proved to be free of any residual microbicidal activity. The endoscope reprocessor, with its processor-generated high-level disinfection solution, successfully reduced the numbers of selected, clinically relevant pathogens to undetectable levels both in the channels and on the outside surfaces of the 4 representative endoscopes tested in this study.
Caremans, Jeroen; Hamans, Evert; Muylle, Ludo; Van de Heyning, Paul; Van Rompaey, Vincent
2016-06-01
Allograft tympano-ossicular systems (ATOS) have proven their use over many decades in tympanoplasty and reconstruction after resection of cholesteatoma. The transcranial bone plug technique has been used in the past 50 years to procure en bloc ATOS (tympanic membrane with malleus, incus and stapes attached). Recently, our group reported the feasibility of the endoscopic procurement technique. The aim of this study was to assess whether clinical outcome is equivalent in ATOS acquired by using the endoscopic procurement technique compared to ATOS acquired by using the transcranial technique. A double-blind randomized controlled audit was performed in a tertiary referral center in patients that underwent allograft tympanoplasty because of chronic otitis media with and without cholesteatoma. Allograft epithelialisation was evaluated at the short-term postoperative visit by microscopic examination. Failures were reported if reperforation was observed. Fifty patients underwent allograft tympanoplasty: 34 received endoscopically procured ATOS and 16 received transcranially procured ATOS. One failed case was observed, in the endoscopic procurement group. We did not observe a statistically significant difference between the two groups in failure rate. This study demonstrates equivalence of the clinical outcome of allograft tympanoplasty using either endoscopic or transcranial procured ATOS and therefore indicates that the endoscopic technique can be considered the new standard procurement technique. Especially because the endoscopic procurement technique has several advantages compared to the former transcranial procurement technique: it avoids risk of prion transmission and it is faster while lacking any noticeable incision.
Tissue loads applied by a novel medical device for closing large wounds.
Katzengold, Rona; Topaz, Moris; Gefen, Amit
2016-02-01
Closure of large soft tissue defects following surgery or trauma as well as closure of large chronic wounds constitutes substantial but common reconstructive challenges. In such cases, an attempt to use conventional suturing will result in high-tension closure, therefore alternative external skin stretching systems were developed. These types of devices were meant to reduce local mechanical loads in the skin and the underlying tissues, taking advantage of the viscoelastic properties of the skin, especially mechanical creep, for primary wound closure. Studies have shown the clinical advantages of skin stretching systems, however, quantitative bioengineering models, demonstrating closure of large wounds, are lacking. Here we present finite element (FE) modeling of the TopClosure(®) tension relief system (TRS) and its biomechanical efficacy in three (real) wound cases, compared with the alternative of a conventional surgical suturing closure technique. Our simulations showed that peak effective stresses on the skin were at least an order of magnitude greater (and sometimes nearly 2 orders-of-magnitude greater) when tension sutures were used with respect to the corresponding TRS data. For the tension suture simulations, the tensile stress was in the range of 415-648 MPa and in the TRS simulations, it was 16-30 MPa. Based on the present computational FE modeling, the TRS reduces localized tissue deformations and stress concentrations in skin and underlying tissues while closing large wounds, compared to the deformations and stresses that are inflicted during the process of suturing. This substantial reduction of loads allows surgeons to better employ the viscoelastic properties of the skin for primary wound closure. Copyright © 2015 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Güleçyüz, Mehmet F; Kraus-Petersen, Michael; Schröder, Christian; Ficklscherer, Andreas; Wagenhäuser, Markus U; Braun, Christian; Müller, Peter E; Pietschmann, Matthias F
2018-02-01
The incidence of osteoporosis and rotator cuff tears increases with age. Cement augmentation of bones is an established method in orthopedic and trauma surgery. This study analyses if polymethylmethacrylate or bioabsorbable cement can improve the primary stability of a bioabsorbable suture anchor in vitro in comparison to a non-augmented suture anchor in osteoporotic human humeri. The trabecular bone mineral density was measured to ensure osteopenic human specimens. Then the poly-l-lactic acid Bio-Corkscrew® FT was implanted in the greater tuberosity footprint with polymethylmethacrylate Refobacin® cement augmentation ( n = 8), with Cerament™ Bone Void Filler augmentation ( n = 8) and without augmentation ( n = 8). Using a cyclic testing protocol, the failure loads, system displacement, and failure modes were recorded. The Cerament™ augmented Bio-Corkscrew® FT yielded the highest failure loads (206.7 N), followed by polymethylmethacrylate Refobacin® augmentation (206.1 N) and without augmentation (160.0 N). The system displacement was lowest for Cerament™ augmentation (0.72 mm), followed by polymethylmethacrylate (0.82 mm) and without augmentation (1.50 mm). Statistical analysis showed no significant differences regarding the maximum failure loads ( p = 0.1644) or system displacement ( p = 0.4199). The main mode of failure for all three groups was suture slippage. The primary stability of the Bio-Corkscrew® FT is not influenced by bone cement augmentation with polymethylmethacrylate Refobacin® or with bioabsorbable Cerament™ in comparison to the non-cemented anchors. The cement augmentation of rotator cuff suture anchors in osteoporotic bones remains questionable since biomechanical tests show no significant advantage.
Fluorescence-Raman Dual Modal Endoscopic System for Multiplexed Molecular Diagnostics
NASA Astrophysics Data System (ADS)
Jeong, Sinyoung; Kim, Yong-Il; Kang, Homan; Kim, Gunsung; Cha, Myeong Geun; Chang, Hyejin; Jung, Kyung Oh; Kim, Young-Hwa; Jun, Bong-Hyun; Hwang, Do Won; Lee, Yun-Sang; Youn, Hyewon; Lee, Yoon-Sik; Kang, Keon Wook; Lee, Dong Soo; Jeong, Dae Hong
2015-03-01
Optical endoscopic imaging, which was recently equipped with bioluminescence, fluorescence, and Raman scattering, allows minimally invasive real-time detection of pathologies on the surface of hollow organs. To characterize pathologic lesions in a multiplexed way, we developed a dual modal fluorescence-Raman endomicroscopic system (FRES), which used fluorescence and surface-enhanced Raman scattering nanoprobes (F-SERS dots). Real-time, in vivo, and multiple target detection of a specific cancer was successful, based on the fast imaging capability of fluorescence signals and the multiplex capability of simultaneously detected SERS signals using an optical fiber bundle for intraoperative endoscopic system. Human epidermal growth factor receptor 2 (HER2) and epidermal growth factor receptor (EGFR) on the breast cancer xenografts in a mouse orthotopic model were successfully detected in a multiplexed way, illustrating the potential of FRES as a molecular diagnostic instrument that enables real-time tumor characterization of receptors during routine endoscopic procedures.
Minimizing Retraction by Pia-Arachnoidal 10-0 Sutures in Intrasulcal Dissection.
Uluc, Kutluay; Cikla, Ulas; Morkan, Deniz B; Sirin, Alperen; Ahmed, Azam S; Swanson, Kyle; Baskaya, Mustafa K
2018-07-01
In contemporary microneurosurgery reducing retraction-induced injury to the brain is essential. Self-retaining retractor systems are commonly used to improve visualization and decrease the repetitive microtrauma, but sometimes self-retaining retractor systems can be cumbersome and the force applied can cause focal ischemia or contusions. This may increase the morbidity and mortality. Here, we describe a technique of retraction using 10-0 sutures in the arachnoid. To evaluate the imaging and clinical results in patients where 10-0 suture retraction was used to aid the surgical procedure. Adjacent cortex was retracted by placing 10-0 nylon suture in the arachnoid of the bank or banks of the sulcus. The suture was secured to the adjacent dural edge by using aneurysm clips, allowing for easy adjustability of the amount of retraction. We retrospectively analyzed the neurological outcome, signal changes in postoperative imaging, and ease of performing surgery in 31 patients with various intracranial lesions including intracranial aneurysms, intra- and extra-axial tumors, and cerebral ischemia requiring arterial bypass. Clinically, there were no injuries, vascular events, or neurological deficits referable to the relevant cortex. Postoperative imaging did not show changes consistent with ischemia or contusion due to the retraction. This technique improved the visualization and illumination of the surgical field in all cases. Retraction of the arachnoid can be used safely in cases where trans-sulcal dissection is required. This technique may improve initial visualization and decrease the need for dynamic or static retraction.
Virtual reality based surgery simulation for endoscopic gynaecology.
Székely, G; Bajka, M; Brechbühler, C; Dual, J; Enzler, R; Haller, U; Hug, J; Hutter, R; Ironmonger, N; Kauer, M; Meier, V; Niederer, P; Rhomberg, A; Schmid, P; Schweitzer, G; Thaler, M; Vuskovic, V; Tröster, G
1999-01-01
Virtual reality (VR) based surgical simulator systems offer very elegant possibilities to both enrich and enhance traditional education in endoscopic surgery. However, while a wide range of VR simulator systems have been proposed and realized in the past few years, most of these systems are far from able to provide a reasonably realistic surgical environment. We explore the basic approaches to the current limits of realism and ultimately seek to extend these based on our description and analysis of the most important components of a VR-based endoscopic simulator. The feasibility of the proposed techniques is demonstrated on a first modular prototype system implementing the basic algorithms for VR-training in gynaecologic laparoscopy.
Liboni, A; Mari, C; Zamboni, P; Uzzau, A; Noce, L; Bucoliero, F; Mele, M; Masala, C
1989-01-01
Staplers have improved the results of esophageal surgery, in our experience and in others experience, as esophago-enteric anastomoses have become safer and faster than when manual suturing is used. Probably one of the last problems in the stapler technique, especially in the thoracic area, is the performance of on adequate esophageal purse-string suture: an improper performance of this suture can cause a dangerous leak of the anastomosis. So, many surgeons, to reduce the risk of esophageal dehiscence connected with the esophageal purse-string, use either purse-string devices or alternative methods such as a second handsewn purse-string, U stitches of the esophagus, etc. We think that the risk of improper anastomoses after esophageal resection can be reduced if the need for the esophageal purse-string can be eliminated. This work shows our personal technique for performing esophagoenterostomy, especially in the thoracic area, using the new CEEA stapler (Autosuture) without esophageal purse-string sutures. According to the modified procedure the stapler anvil and the mini rod are introduced in the esophagectomy and a 2-0 thread is knotted around the CEEA mini rod. Then the esophageal mutilated part is closed by a linear stapler keeping a syringe needle, which contains the thread, through the linear suture. Then, using the thread as a pulling system, the surgeon makes the needle and the tip of the mini rod slide out of the esophageal suture. Now the surgeon can reassemble the CEEA and perform the anastomosis. There are many clinical reports that cite no leaks following circular stapled anastomoses across linear stapled closures.
Schwab, M.; Ratschbacher, L.; Siebel, W.; McWilliams, M.; Minaev, V.; Lutkov, V.; Chen, F.; Stanek, K.; Nelson, B.; Frisch, W.; Wooden, J.L.
2004-01-01
Magmatic rocks and depositional setting of associated volcaniclastic strata along a north-south traverse spanning the southern Tien Shan and eastern Pamirs of Kyrgyzstan and Tajikistan constrain the tectonics of the Pamirs and Tibet. The northern Pamirs and northwestern Tibet contain the north facing Kunlun suture, the south facing Jinsha suture, and the intervening Carboniferous to Triassic Karakul-Mazar subduction accretion system; the latter is correlated with the Songpan-Garze-Hoh Xi system of Tibet. The Kunlun arc is a composite early Paleozoic to late Paleozoic-Triassic arc. Arc formation in the Pamirs is characterized by ???370-320 Ma volcanism that probably continued until the Triassic. The cryptic Tanymas suture of the southern northern Pamirs is part of the Jinsha suture. A massive ??????227 Ma batholith stitches the Karakul-Mazar complex in the Pamirs. There are striking similarities between the Qiangtang block in the Pamirs and Tibet. Like Tibet, the regional structure of the Pamirs is an anticlinorium that includes the Muskol and Sares domes. Like Tibet, the metamorphic rocks in these domes are equivalents to the Karakul-Mazar-Songpan-Garze system. Granitoids intruding the Qiangtang block yield ???200-230 Ma ages in the Pamirs and in central Tibet. The stratigraphy of the eastern Pshart area in the Pamirs is similar to the Bangong-Nujiang suture zone in the Amdo region of eastern central Tibet, but a Triassic ocean basin sequence is preserved in the Pamirs. Arc-type granitoids that intruded into the eastern Pshart oceanic-basin-arc sequence (???190-160 Ma) and granitoids that cut the southern Qiangtang block (???170-160 Ma) constitute the Rushan-Pshart arc. Cretaceous plutons that intruded the central and southern Pamirs record a long-lasting magmatic history. Their zircons and those from late Miocene xenoliths show that the most distinct magmatic events were Cambro-Ordovician (???410-575 Ma), Triassic (???210-250 Ma; likely due to subduction along the Jinsha suture), Middle Jurassic (???147-195 Ma; subduction along Rushan-Pshart suture), and mainly Cretaceous. Middle and Late Cretaceous magmatism may reflect arc activity in Asia prior to the accretion of the Karakoram block and flat-slab subduction along the Shyok suture north of the Kohistan-Ladakh arc, respectively. Before India and Asia collided, the Pamir region from the Indus-Yarlung to the Jinsha suture was an Andean-style plate margin. Our analysis suggests a relatively simple crustal structure for the Pamirs and Tibet. From the Kunlun arc in the north to the southern Qiangtang block in the south the Pamirs and Tibet likely have a dominantly sedimentary crust, characterized by Karakul-Mazar-Songpan-Garze accretionary wedge rocks. The crust south of the southern Qiangtang block is likely of granodioritic composition, reflecting long-lived subduction, arc formation, and Cretaceous-Cenozoic underthrusting. Copyright 2004 by the American Geophysical Union.
Sun, Zhen-Jun; Ye, Bo; Sun, Yi; Zhang, Hong-Hai; Liu, Sheng
2014-07-01
This article describes a novel magnetically maneuverable capsule endoscope system with direction reference for image navigation. This direction reference was employed by utilizing a specific magnet configuration between a pair of external permanent magnets and a magnetic shell coated on the external capsule endoscope surface. A pair of customized Cartesian robots, each with only 4 degrees of freedom, was built to hold the external permanent magnets as their end-effectors. These robots, together with their external permanent magnets, were placed on two opposite sides of a "patient bed." Because of the optimized configuration based on magnetic analysis between the external permanent magnets and the magnetic shell, a simplified control strategy was proposed, and only two parameters, yaw step angle and moving step, were necessary for the employed robotic system. Step-by-step experiments demonstrated that the proposed system is capable of magnetically maneuvering the capsule endoscope while providing direction reference for image navigation. © IMechE 2014.
Development of a biologically inspired locomotion system for a capsule endoscope.
Hosokawa, Daisuke; Ishikawa, Takuji; Morikawa, Hirohisa; Imai, Yohsuke; Yamaguchi, Takami
2009-12-01
A capsule endoscope has a limited ability to obtain images of the digestive organs because its movement depends on peristaltic motion. To overcome this problem, capsule endoscopes require a propulsion system. This paper proposes a propulsion system for a capsule endoscope that mimics the locomotive mechanism of snails and earthworms. The prototype crawler can elongate and contract itself longitudinally and adhere to a wall via suction cups. We investigated the effect of the inclination angle of the propulsion plane, the mucus viscosity between the propulsion plane and the crawler, and the stiffness of the propulsion plane on the locomotion of the prototype crawler. We found that the crawler could move on a rubber sheet and on inclined planes covered with mucus. We discussed advantages and limitations of the prototype crawler compared to the different locomotive systems developed in former studies. We believe that the prototype crawler provides a better understanding of the propulsion mechanism for use in the gastrointestinal tract. Copyright (c) 2009 John Wiley & Sons, Ltd.
[Video recording system of endoscopic procedures for digital forensics].
Endo, Chiaki; Sakurada, A; Kondo, T
2009-07-01
Recently, endoscopic procedures including surgery, intervention, and examination have been widely performed. Medical practitioners are required to record the procedures precisely in order to check the procedures retrospectively and to get the legally reliable record. Medical Forensic System made by KS Olympus Japan offers 2 kinds of movie and patient's data, such as heart rate, blood pressure, and Spo, which are simultaneously recorded. We installed this system into the bronchoscopy room and have experienced its benefit. Under this system, we can get bronchoscopic image, bronchoscopy room view, and patient's data simultaneously. We can check the quality of the bronchoscopic procedures retrospectively, which is useful for bronchoscopy staff training. Medical Forensic System should be installed in any kind of endoscopic procedures.
The role of three-dimensional visualization in robotics-assisted cardiac surgery
NASA Astrophysics Data System (ADS)
Currie, Maria; Trejos, Ana Luisa; Rayman, Reiza; Chu, Michael W. A.; Patel, Rajni; Peters, Terry; Kiaii, Bob
2012-02-01
Objectives: The purpose of this study was to determine the effect of three-dimensional (3D) versus two-dimensional (2D) visualization on the amount of force applied to mitral valve tissue during robotics-assisted mitral valve annuloplasty, and the time to perform the procedure in an ex vivo animal model. In addition, we examined whether these effects are consistent between novices and experts in robotics-assisted cardiac surgery. Methods: A cardiac surgery test-bed was constructed to measure forces applied by the da Vinci surgical system (Intuitive Surgical, Sunnyvale, CA) during mitral valve annuloplasty. Both experts and novices completed roboticsassisted mitral valve annuloplasty with 2D and 3D visualization. Results: The mean time for both experts and novices to suture the mitral valve annulus and to tie sutures using 3D visualization was significantly less than that required to suture the mitral valve annulus and to tie sutures using 2D vision (p∠0.01). However, there was no significant difference in the maximum force applied by novices to the mitral valve during suturing (p = 0.3) and suture tying (p = 0.6) using either 2D or 3D visualization. Conclusion: This finding suggests that 3D visualization does not fully compensate for the absence of haptic feedback in robotics-assisted cardiac surgery. Keywords: Robotics-assisted surgery, visualization, cardiac surgery
[The treatment principles of frontal sinus tract after the frontal approach craniotomy].
Yu, Huanxin; Li, Haiyan; Liu, Gang
2015-12-01
To investigate the causes, clinical manifestation and treatment principles of frontal sinus tract after the frontal approach craniotomy. The clinic data of 13 patients with frontal skin sinus tract after the frontal approach craniotomy were retrospectively analyzed. All of them were described in the clinical record to have undergone frontal sinus mucosa pushing down or shaving and bone wax filling in the frontal sinus during the surgery, of whom 3 cases had history of frontal abscess incision drainage. All patients were performed endoscopic frontal sinus surgery and forehead skin sinus tract excision and suture. All of the patients successfully recovered after one-stage operation, and the frontal skin sinus tract was healed. The frontal approach craniotomy with postoperative frontal sinus tract was related with the improper use of bone wax tamponade and sealing of frontal sinus. The treatment principles were to remove bone wax, remove inflammatory granulation tissue around the sinus tract, and to open frontal sinus and promote frontal sinus drainage.
Tracheoesophageal fistula--a complication of prolonged tracheal intubation.
Paraschiv, M
2014-01-01
Tracheoesophageal fistula most commonly occurs as a complication of prolonged tracheal intubation. The incidence decreased after the use of low pressure and high volume endotracheal cuffs, but the intensive care units continue to provide such cases. The abnormal tracheoesophageal communication causes pulmonary contamination (with severe suppuration) and impossibility to feed the patient. The prognosis is reserved, because most patients are debilitated and ventilator dependent, with severe neurological and cardiovascular diseases. The therapeutic options are elected based on respiratory, neurological and nutritional status. The aim of conservative treatment is to stop the contamination (drainage gastrostomy, feeding jejunostomy) and to treat the pulmonary infection and biological deficits. Endoscopic therapies can be tried in cases with surgical contraindication. Operation is addressed to selected cases and consists in the dissolution of the fistula, esophageal suture with or without segmental tracheal resection associated. Esophageal diversion is rarely required. The correct indication and timing of surgery, proper surgical technique and postoperative care are prerequisites for adequate results.
Tracheoesophageal fistula - a complication of prolonged tracheal intubation
Paraschiv, M
2014-01-01
Tracheoesophageal fistula most commonly occurs as a complication of prolonged tracheal intubation. The incidence decreased after the use of low pressure and high volume endotracheal cuffs, but the intensive care units continue to provide such cases. The abnormal tracheoesophageal communication causes pulmonary contamination (with severe suppuration) and impossibility to feed the patient. The prognosis is reserved, because most patients are debilitated and ventilator dependent, with severe neurological and cardiovascular diseases. The therapeutic options are elected based on respiratory, neurological and nutritional status. The aim of conservative treatment is to stop the contamination (drainage gastrostomy, feeding jejunostomy) and to treat the pulmonary infection and biological deficits. Endoscopic therapies can be tried in cases with surgical contraindication. Operation is addressed to selected cases and consists in the dissolution of the fistula, esophageal suture with or without segmental tracheal resection associated. Esophageal diversion is rarely required. The correct indication and timing of surgery, proper surgical technique and postoperative care are prerequisites for adequate results. PMID:25713612
Takazawa, Shinya; Uchida, Hiroo; Kawashima, Hiroshi; Tanaka, Yujiro; Sato, Kaori; Jimbo, Takahiro; Deie, Kyoichi; Koiwai, Kazuki; Nomura, Koji; Iwanaka, Tadashi
2014-08-01
A newborn female was transferred to our hospital presenting with severe respiratory distress. She underwent tracheal intubation and nasogastric tubing. Investigations revealed a congenital extrahepatic portosystemic shunt (CEPS) type 1, biliary atresia, heterotaxia, polysplenia, malrotation and a double aortic arch (DAA). She underwent the Kasai portoenterostomy and the Ladd procedure when she was 29 days old. On postoperative day 20, she developed sudden hematemesis with bright red blood. Endoscopy showed massive bleeding from an esophageal ulcer, and endoscopic therapy was performed successfully. During left thoracotomy, an aortoesophageal fistula (AEF) was detected and repaired by direct suturing. The postoperative course was uneventful. CEPS type 1 is commonly associated with other congenital malformations; however, there have been no previous reports of an association between CEPS and DAA. Nasogastric tube insertion in a patient with DAA can result in catastrophic AEF. The treatment strategy should be carefully considered in patients with CEPS type 1 and multiple congenital fetal anomalies.
Comparison of the cheese-wiring effects among three sutures used in rotator cuff repair
Lambrechts, Mark; Nazari, Behrooz; Dini, Arash; O'Brien, Michael J.; Heard, Wendell M. R.; Savoie, Felix H.; You, Zongbing
2014-01-01
Purpose: The goal of this study was to compare the cheese-wiring effects of three sutures with different coefficients of friction. Materials and Methods: Sixteen human cadaveric shoulders were dissected to expose the distal supraspinatus and infraspinatus muscle tendons. Three sutures were stitched through the tendons: #2 Orthocord™ suture (reference #223114, DePuy Mitek, Inc., Raynham, MA), #2 ETHIBOND* EXCEL Suture, and #2 FiberWire® suture (FiberWire®, Arthrex, Naples, FL). The sutures were pulled by cyclic axial forces from 10 to 70 N at 1 Hz for 1000 cycles through a MTS machine. The cut-through distance on the tendon was measured with a digital caliper. Results: The cut-through distance in the supraspinatus tendons (mean ± standard deviation, n = 12) were 2.9 ± 0.6 mm for #2 Orthocord™ suture, 3.2 ± 1.2 mm for #2 ETHIBOND* suture, and 4.2 ± 1.7 mm for #2 FiberWire® suture. The differences were statistically significant analyzing with analysis of variance (P = 0.047) and two-tailed Student's t-test, which showed significance between Orthocord™ and FiberWire® sutures (P = 0.026), but not significant between Orthocord™ and ETHIBOND* sutures (P = 0.607) or between ETHIBOND* and FiberWire® sutures (P = 0.103). Conclusion: The cheese-wiring effect is less in the Orthocord™ suture than in the FiberWire® suture in human cadaveric supraspinatus tendons. Clinical Relevance: Identification of sutures that cause high levels of tendon cheese-wiring after rotator cuff repair can lead to better suture selection. PMID:25258499
Advanced endoscopic imaging to improve adenoma detection
Neumann, Helmut; Nägel, Andreas; Buda, Andrea
2015-01-01
Advanced endoscopic imaging is revolutionizing our way on how to diagnose and treat colorectal lesions. Within recent years a variety of modern endoscopic imaging techniques was introduced to improve adenoma detection rates. Those include high-definition imaging, dye-less chromoendoscopy techniques and novel, highly flexible endoscopes, some of them equipped with balloons or multiple lenses in order to improve adenoma detection rates. In this review we will focus on the newest developments in the field of colonoscopic imaging to improve adenoma detection rates. Described techniques include high-definition imaging, optical chromoendoscopy techniques, virtual chromoendoscopy techniques, the Third Eye Retroscope and other retroviewing devices, the G-EYE endoscope and the Full Spectrum Endoscopy-system. PMID:25789092
Lee, Jun; Kim, Dong-Min; Yun, Na Ra; Kim, Young Dae; Park, Chan Guk; Kim, Man Woo
2016-01-01
Scrub typhus is an infectious disease caused by Orientia tsutsugamushi-induced systemic vasculitis, but the involvement of the gastrointestinal tract and the endoscopic findings associated with scrub typhus are not well understood. We performed a prospective study and recommend performing esophagogastroduodenoscopy (EGD) for all possible scrub typhus patients, regardless of gastrointestinal symptoms. Gastrointestinal symptoms, endoscopic findings and clinical severity based on organ involvement and ICU admission were analyzed. Gastrointestinal symptoms occurred in up to 76.4% of scrub typhus patients. The major endoscopic findings were ulcers (43/127, 33.9%). Interestingly, 7.1% (9/127) of the patients presented with esophageal candidiasis. There was no correlation between the presence or absence of gastrointestinal symptoms and the endoscopic grade (P = 0.995). However, there was a positive correlation between the clinical severity and the endoscopic findings (P = 0.001). Sixty-three percent of the patients presented with erosion or ulcers on prospectively performed endoscopic evaluations, irrespective of gastrointestinal symptoms. Gastrointestinal symptoms did not reflect the need for endoscopy. Scrub typhus patients could have significant endoscopic abnormalities even in the absence of gastrointestinal symptoms.
Harima, Hirofumi; Hamabe, Kouichi; Hisano, Fusako; Matsuzaki, Yuko; Itoh, Tadahiko; Sanuki, Kazutoshi; Sakaida, Isao
2018-05-23
An 89-year-old man was referred to our hospital for treatment of hepatolithiasis causing recurrent cholangitis. He had undergone a prior Whipple procedure. Computed tomography demonstrated left-sided hepatolithiasis. First, we conducted peroral direct cholangioscopy (PDCS) using an ultraslim endoscope. Although PDCS was successfully conducted, it was unsuccessful in removing all the stones. The stones located in the B2 segment were difficult to remove because the endoscope could not be inserted deeply into this segment due to the small size of the intrahepatic bile duct. Next, we substituted the endoscope with an upper gastrointestinal endoscope. After positioning the endoscope, the SpyGlass digital system (SPY-DS) was successfully inserted deep into the B2 segment. Upon visualizing the residual stones, we conducted SPY-DS-guided electrohydraulic lithotripsy. The stones were disintegrated and completely removed. In cases of PDCS failure, a treatment strategy using the SPY-DS can be considered for patients with hepatolithiasis after a Whipple procedure.
Qiu, Lijun; Zhou, Zhihui; Liu, Qifang; Ni, Yuhua; Zhao, Feng; Cheng, Hao
2015-08-01
Digestive endoscopy is an important technique for the diagnosis and treatment of digestive system disease. To assure medical safety, a digestive endoscope must be cleaned and disinfected before its use in an operation on the next patient. The most common treatment procedure on a digestive endoscope is high-level disinfection. The potential risk associated with digestive endoscopes is always the focus of endoscopic management in clinical practice. In this study, a polluted pancreatic and biliary endoscope after surgery was cleaned and disinfected multiple times with the standard procedure but still tested positive for Pseudomonas aeruginosa culture, which is very rare and has not been reported in China or abroad. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.
Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz
2015-06-01
The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.
Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao
2017-08-01
Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.
Kirsch, A J; Chang, D T; Kayton, M L; Libutti, S K; Connor, J P; Hensle, T W
1996-01-01
Tissue welding using laser-activated protein solders may soon become an alternative to sutured tissue approximation. In most cases, approximating sutures are used both to align tissue edges and provide added tensile strength. Collateral thermal injury, however, may cause disruption of tissue alignment and weaken the tensile strength of sutures. The objective of this study was to evaluate the effect of laser welding on the tensile strength of suture materials used in urologic surgery. Eleven types of sutures were exposed to diode laser energy (power density = 15.9 W/cm2) for 10, 30, and 60 seconds. Each suture was compared with and without the addition of dye-enhanced albumin-based solder. After exposure, each suture material was strained (2"/min) until ultimate breakage on a tensometer and compared to untreated sutures using ANOVA. The strength of undyed sutures were not significantly affected; however, violet and green-dyed sutures were in general weakened by laser exposure in the presence of dye-enhanced glue. Laser activation of the smallest caliber, dyed sutures (7-0) in the presence of glue caused the most significant loss of tensile strength of all sutures tested. These results indicate that the thermal effects of laser welding using our technique decrease the tensile strength of dyed sutures. A thermally resistant suture material (undyed or clear) may prevent disruption of wounds closed by laser welding techniques.
A non-invasive navigation system for retargeting gastroscopic lesions.
Liu, Jiquan; Wang, Bin; Hu, Weiling; Zong, Yun; Si, Jianmin; Duan, Huilong
2014-01-01
Biopsy is a traditional endoscopic surveillance of premalignant gastric lesions, and endoscopic tattooing is used for marking the biopsy's location. However, the tattooing has several disadvantages. For example, the procedure is an invasive operation and may not be durable due to the diffusion. Moreover, it is procedurally cumbersome with an associated risk of technical failure. In this study, a computer aided endoscopic navigation system (CAEN system) was developed for a non-invasive biopsy procedure. The CAEN system consists of a new, designed six degree of freedom (6-DOF) tracking endoscope device and a computer simulated work station. During the procedure, the endoscopist uses the tip of the tracking endoscope to touch the lesion. Then, the lesion's location is recorded in the work station, which then guides the endoscopist in retargeting the lesions in the follow-ups. The clinical experimental results demonstrate that the accuracy at the angularis is 5.2 ± 2.8 mm, at the antral lesser curvature is 7.2 ± 2.0 mm, at the antral greater curvature is 6.3 ± 3.1 mm, at the antral posterior wall is 8.2 ± 1.6 mm, and at the antral anterior wall is 7.9 ± 1.3 mm. The mean accuracy is 7.5 mm, and the P-value is 0.023, which is likely suitable for clinical practice. Furthermore, the proposed CAEN system requires less procedural time than the tattooing.
Augmented reality image guidance for minimally invasive coronary artery bypass
NASA Astrophysics Data System (ADS)
Figl, Michael; Rueckert, Daniel; Hawkes, David; Casula, Roberto; Hu, Mingxing; Pedro, Ose; Zhang, Dong Ping; Penney, Graeme; Bello, Fernando; Edwards, Philip
2008-03-01
We propose a novel system for image guidance in totally endoscopic coronary artery bypass (TECAB). A key requirement is the availability of 2D-3D registration techniques that can deal with non-rigid motion and deformation. Image guidance for TECAB is mainly required before the mechanical stabilization of the heart, thus the most dominant source of non-rigid deformation is the motion of the beating heart. To augment the images in the endoscope of the da Vinci robot, we have to find the transformation from the coordinate system of the preoperative imaging modality to the system of the endoscopic cameras. In a first step we build a 4D motion model of the beating heart. Intraoperatively we can use the ECG or video processing to determine the phase of the cardiac cycle. We can then take the heart surface from the motion model and register it to the stereo-endoscopic images of the da Vinci robot using 2D-3D registration methods. We are investigating robust feature tracking and intensity-based methods for this purpose. Images of the vessels available in the preoperative coordinate system can then be transformed to the camera system and projected into the calibrated endoscope view using two video mixers with chroma keying. It is hoped that the augmented view can improve the efficiency of TECAB surgery and reduce the conversion rate to more conventional procedures.
A robust motion estimation system for minimal invasive laparoscopy
NASA Astrophysics Data System (ADS)
Marcinczak, Jan Marek; von Öhsen, Udo; Grigat, Rolf-Rainer
2012-02-01
Laparoscopy is a reliable imaging method to examine the liver. However, due to the limited field of view, a lot of experience is required from the surgeon to interpret the observed anatomy. Reconstruction of organ surfaces provide valuable additional information to the surgeon for a reliable diagnosis. Without an additional external tracking system the structure can be recovered from feature correspondences between different frames. In laparoscopic images blurred frames, specular reflections and inhomogeneous illumination make feature tracking a challenging task. We propose an ego-motion estimation system for minimal invasive laparoscopy that can cope with specular reflection, inhomogeneous illumination and blurred frames. To obtain robust feature correspondence, the approach combines SIFT and specular reflection segmentation with a multi-frame tracking scheme. The calibrated five-point algorithm is used with the MSAC robust estimator to compute the motion of the endoscope from multi-frame correspondence. The algorithm is evaluated using endoscopic videos of a phantom. The small incisions and the rigid endoscope limit the motion in minimal invasive laparoscopy. These limitations are considered in our evaluation and are used to analyze the accuracy of pose estimation that can be achieved by our approach. The endoscope is moved by a robotic system and the ground truth motion is recorded. The evaluation on typical endoscopic motion gives precise results and demonstrates the practicability of the proposed pose estimation system.
A navigation system for flexible endoscopes using abdominal 3D ultrasound
NASA Astrophysics Data System (ADS)
Hoffmann, R.; Kaar, M.; Bathia, Amon; Bathia, Amar; Lampret, A.; Birkfellner, W.; Hummel, J.; Figl, M.
2014-09-01
A navigation system for flexible endoscopes equipped with ultrasound (US) scan heads is presented. In contrast to similar systems, abdominal 3D-US is used for image fusion of the pre-interventional computed tomography (CT) to the endoscopic US. A 3D-US scan, tracked with an optical tracking system (OTS), is taken pre-operatively together with the CT scan. The CT is calibrated using the OTS, providing the transformation from CT to 3D-US. Immediately before intervention a 3D-US tracked with an electromagnetic tracking system (EMTS) is acquired and registered intra-modal to the preoperative 3D-US. The endoscopic US is calibrated using the EMTS and registered to the pre-operative CT by an intra-modal 3D-US/3D-US registration. Phantom studies showed a registration error for the US to CT registration of 5.1 mm ± 2.8 mm. 3D-US/3D-US registration of patient data gave an error of 4.1 mm compared to 2.8 mm with the phantom. From this we estimate an error on patient experiments of 5.6 mm.
NASA Astrophysics Data System (ADS)
Bierlein, Frank P.; Betts, Peter G.
2004-09-01
In marked contrast to Palaeoproterozoic Laurentia, the location of sutures and boundaries of discrete crustal fragments amalgamated during Palaeoproterozoic formation of the North Australian Craton remain highly speculative. Interpretations of suture locations have relied heavily on the analysis of regional geophysical datasets because of sparse exposure of rocks of the appropriate age. The Mount Isa Fault Zone has been interpreted as one such Palaeoproterozoic terrane-bounding suture. Furthermore, the coincidence of this fault zone with major shale-hosted massive sulphide Pb-Zn-Ag orebodies has led to speculations that trans-lithospheric faults may be an important ingredient for the development of this deposit type. This study has integrated geophysical and geochemical data to test the statute of the Mount Isa Fault as a terrane-bounding suture. Forward modelling of gravity data shows that basement rocks on either side of the Mount Isa Fault have similar densities. These interpretations are consistent with geochemical observations and Sm-Nd data that suggest that basement lithologies on either side of the Mount Isa Fault are geochemically and isotopically indistinguishable from each other, and that the Mount Isa Fault is unlikely to represent a suture zone that separates different Palaeoproterozoic terranes. Our data indicate that the crustal blocks on both sides of the Mount Isa Fault Zone must have been in within close proximity of each other since the Palaeoproterozoic, and that the Western Fold Belt was part of the (ancestral) North Australian Craton well before the ˜1.89-1.87 Ga Barramundi Orogeny. It appears that deep crustal variations in density may be related to the boundary between a shallowly west-dipping high-density mafic to ultramafic plate and low-density basement rocks. This interpretation in turn impacts on crustal-scale models for the development of shale-hosted massive sulphide Pb-Zn mineralisation, which do not require trans-lithospheric faults to tap deep-seated metal reservoirs and/or mantle plumbing systems. The approach applied herein demonstrates the value of multi-disciplinary investigations to the critical assessment of long-lived Proterozoic fault systems which, in the absence of methodical analysis, are commonly assumed to represent terrane-bounding sutures.
Endoscopic surgical management of sinonasal inverted papilloma extending to frontal sinuses.
Takahashi, Yukiko; Shoji, Fumi; Katori, Yukio; Hidaka, Hiroshi; Noguchi, Naoya; Abe, Yasuhiro; Kakuta, Risako Kakuta; Suzuki, Takahiro; Suzuki, Yusuke; Ohta, Nobuo; Kakehata, Seiji; Okamoto, Yoshitaka
2016-11-10
Sinonasal inverted papilloma has been traditionally managed with external surgical approaches. Advances in imaging guidance systems, surgical instrumentation, and intraoperative multi-visualization have led to a gradual shift from external approaches to endoscopic surgery. However, for anatomical and technical reasons, endoscopic surgery of sinonasal inverted papilloma extending to the frontal sinuses is still challenging. Here, we present our experience in endoscopic surgical management of sinonasal inverted papilloma extending to one or both frontal sinuses. We present 10 cases of sinonasal inverted papilloma extending to the frontal sinuses and successfully removed by endoscopic median drainage (Draf III procedure) under endoscopic guidance without any additional external approach. The whole cavity of the frontal sinuses was easily inspected at the end of the surgical procedure. No early or late complications were observed. No recurrence was identified after an average follow-up period of 39.5 months. Use of an endoscopic median drainage approach to manage sinonasal inverted papilloma extending to one or both frontal sinuses is feasible and seems effective.
Design of a handheld optical coherence microscopy endoscope
NASA Astrophysics Data System (ADS)
Korde, Vrushali R.; Liebmann, Erica; Barton, Jennifer K.
2011-06-01
Optical coherence microscopy (OCM) combines coherence gating, high numerical aperture optics, and a fiber-core pinhole to provide high axial and lateral resolution with relatively large depth of imaging. We present a handheld rigid OCM endoscope designed for small animal surgical imaging, with a 6-mm diam tip, 1-mm scan width, and 1-mm imaging depth. X-Y scanning is performed distally with mirrors mounted to micro galvonometer scanners incorporated into the endoscope handle. The endoscope optical design consists of scanning doublets, an afocal Hopkins relay lens system, a 0.4 numerical aperture water immersion objective, and a cover glass. This endoscope can resolve laterally a 1.4-μm line pair feature and has an axial resolution (full width half maximum) of 5.4 μm. Images taken with this endoscope of fresh ex-vivo mouse ovaries show structural features, such as corpus luteum, primary follicles, growing follicles, and fallopian tubes. This rigid handheld OCM endoscope can be useful for a variety of minimally invasive and surgical imaging applications.
Ono, Y.; Woodmass, J. M.; Nelson, A. A.; Boorman, R. S.; Thornton, G. M.
2016-01-01
Objectives This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Methods Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’. Results In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed ‘suture cutting through bone’ as the predominant source of suture displacement in cadaveric bone (qualitative) and greater ‘suture cutting through bone’ comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Conclusions Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone. Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269–275. DOI: 10.1302/2046-3758.56.2000535. PMID:27357383
Ono, Y; Woodmass, J M; Nelson, A A; Boorman, R S; Thornton, G M; Lo, I K Y
2016-06-01
This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of 'suture cutting through bone'. In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed 'suture cutting through bone' as the predominant source of suture displacement in cadaveric bone (qualitative) and greater 'suture cutting through bone' comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone.Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269-275. DOI: 10.1302/2046-3758.56.2000535. © 2016 Lo et al.
2013-06-26
Chatwiriyacharoen14 Betadine gauze Unclear 5 Unclear Until suitable for suture Purulent dis- charge or mate- rial or surround- ing cellulitis Unclear Reopened and...Opened McGreal et al20 Povidone-io- dine (1%)- soaked wick Subcuticu- lar suture 4 Unclear Steri-Strips on day 4 Cellulitis , cul- ture-positive
Hennecke, Kathleen; Redeker, Joern; Kuhbier, Joern W.; Strauss, Sarah; Allmeling, Christina; Kasper, Cornelia; Reimers, Kerstin; Vogt, Peter M.
2013-01-01
Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials. PMID:23613793
Diana, Michele; Mutter, Didier; Lindner, Véronique; Vix, Michel; Chung, Hyunsoo; Demartines, Nicolas; Marescaux, Jacques
2014-05-01
The aim of our study was to assess the feasibility of minimally invasive digestive anastomosis using a modular flexible magnetic anastomotic device made up of a set of two flexible chains of magnetic elements. The assembly possesses a non-deployed linear configuration which allows it to be introduced through a dedicated small-sized applicator into the bowel where it takes the deployed form. A centering suture allows the mating between the two parts to be controlled in order to include the viscerotomy between the two magnetic rings and the connected viscera. Eight pigs were involved in a 2-week survival experimental study. In five colorectal anastomoses, the proximal device was inserted by a percutaneous endoscopic technique, and the colon was divided below the magnet. The distal magnet was delivered transanally to connect with the proximal magnet. In three jejunojejunostomies, the first magnetic chain was injected in its linear configuration through a small enterotomy. Once delivered, the device self-assembled into a ring shape. A second magnet was injected more distally through the same port. The centering sutures were tied together extracorporeally and, using a knot pusher, magnets were connected. Ex vivo strain testing to determine the compression force delivered by the magnetic device, burst pressure of the anastomosis, and histology were performed. Mean operative time including endoscopy was 69.2 ± 21.9 min, and average time to full patency was 5 days for colorectal anastomosis. Operative times for jejunojejunostomies were 125, 80, and 35 min, respectively. The postoperative period was uneventful. Burst pressure of all anastomoses was ≥ 110 mmHg. Mean strain force to detach the devices was 6.1 ± 0.98 and 12.88 ± 1.34 N in colorectal and jejunojejunal connections, respectively. Pathology showed a mild-to-moderate inflammation score. The modular magnetic system showed enormous potential to create minimally invasive digestive anastomoses, and may represent an alternative to stapled anastomoses, being easy to deliver, effective, and low cost.
Cheon, Young Koog; Lee, Tae Yoon; Sung, In Kyung; Shim, Chan Sup
2014-01-01
Most delivery devices used for esophageal stents for obstructing esophageal cancer have a diameter of 5-8 mm, a size that is too large to pass through the endoscopic working channel. The conventional esophageal stent requires multiple endoscopic procedures for implantation. The purpose of the present study was to evaluate the clinical feasibility of a newly developed fully covered, self-expanding, through-the-scope (TTS) esophageal stent in a porcine model. Eight mini pigs were used. Each animal underwent placement of a fully covered TTS stent (Hanarostent® Esophagus TTS) and the upper part of the stent was fixed by suturing with nylon. Fluoroscopy was carried out every week to assess migration of the stent. Follow-up endoscopy was done every month for 3 months to evaluate the status of the membrane, stent mesh, grade of tissue hyperplasia, and mucosal changes at both ends of the stent. All stents were successfully and easily deployed, and were placed without any distortion in the stent or without rupture of the membrane. In two cases, stent migration was observed after 8 weeks. No case of membrane disruption, stent mesh disruption or tissue hyperplasia at either end of the stent was found at the completion of the study. Our findings indicate that the new fully covered self-expanding TTS esophageal stent is easy and simple to implant, and no significant distortion of mesh or disruption of membrane was observed. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Musani, Ali I; Jensen, Kurt; Mitchell, John D; Weyant, Michael; Garces, Katherine; Hsia, David
2012-04-01
Benign tracheal obstruction occurs for a variety of reasons. Bronchoscopic intervention includes silicone stent placement, which effectively maintains airway patency. Stent migration is a common complication, particularly when placed in the proximal trachea. We used a novel technique of securing tracheal stents with a percutaneous endoscopic gastrostomy tube fastener (PEG-TF) to prevent stent migration. The purpose of this study was to determine the feasibility of securing silicone stents in the proximal trachea with PEG-TF. Silicone stents were placed under general anesthesia by rigid bronchoscopy in 7 consecutive patients with inoperable benign proximal tracheal obstruction. PEG-TFs were placed under sterile conditions with direct bronchoscopic visualization. A needle was inserted through the anterior neck and silicone stent wall allowing stylet introduction of a T-fastener into the interior of the stent. The T-fastener was secured externally by a metal clamp and cotton pledget at the surface of the neck. Patients had routine outpatient follow-up and covered the external portion of the PEG-TF with a waterproof dressing when showering. All 7 PEG-TFs were placed without complications. The PEG-TFs were left in for 1 to 25 weeks. Complications of the PEG-TF included localized cellulitis and suture breakage. No stent migration occurred while the fastener was in place. Two stents were removed within 2 weeks due to patient's difficulty tolerating the stent. Securing silicone stents in the proximal trachea is feasible and may prevent stent migration, but further study and possible modification of the PEG-TF device are needed.
Judson, Christopher H.; Charette, Ryan; Cavanaugh, Zachary; Shea, Kevin P.
2016-01-01
Background: Traditional Bankart repair using bone tunnels has a reported failure rate between 0% and 5% in long-term studies. Arthroscopic Bankart repair using suture anchors has become more popular; however, reported failure rates have been cited between 4% and 18%. There have been no satisfactory explanations for the differences in these outcomes. Hypothesis: Bone tunnels will provide increased coverage of the native labral footprint and demonstrate greater load to failure and stiffness and decreased cyclic displacement in biomechanical testing. Study Design: Controlled laboratory study. Methods: Twenty-two fresh-frozen cadaveric shoulders were used. For footprint analysis, the labral footprint area was marked and measured using a Microscribe technique in 6 specimens. A 3-suture anchor repair was performed, and the area of the uncovered footprint was measured. This was repeated with traditional bone tunnel repair. For the biomechanical analysis, 8 paired specimens were randomly assigned to bone tunnel or suture anchor repair with the contralateral specimen assigned to the other technique. Each specimen underwent cyclic loading (5-25 N, 1 Hz, 100 cycles) and load to failure (15 mm/min). Displacement was measured using a digitized video recording system. Results: Bankart repair with bone tunnels provided significantly more coverage of the native labral footprint than repair with suture anchors (100% vs 27%, P < .001). Repair with bone tunnels (21.9 ± 8.7 N/mm) showed significantly greater stiffness than suture anchor repair (17.1 ± 3.5 N/mm, P = .032). Mean load to failure and gap formation after cyclic loading were not statistically different between bone tunnel (259 ± 76.8 N, 0.209 ± 0.064 mm) and suture anchor repairs (221.5 ± 59.0 N [P = .071], 0.161 ± 0.51 mm [P = .100]). Conclusion: Bankart repair with bone tunnels completely covered the footprint anatomy while suture anchor repair covered less than 30% of the native footprint. Repair using bone tunnels resulted in significantly greater stiffness than repair with suture anchors. Load to failure and gap formation were not significantly different. PMID:26779555
Judson, Christopher H; Charette, Ryan; Cavanaugh, Zachary; Shea, Kevin P
2016-01-01
Traditional Bankart repair using bone tunnels has a reported failure rate between 0% and 5% in long-term studies. Arthroscopic Bankart repair using suture anchors has become more popular; however, reported failure rates have been cited between 4% and 18%. There have been no satisfactory explanations for the differences in these outcomes. Bone tunnels will provide increased coverage of the native labral footprint and demonstrate greater load to failure and stiffness and decreased cyclic displacement in biomechanical testing. Controlled laboratory study. Twenty-two fresh-frozen cadaveric shoulders were used. For footprint analysis, the labral footprint area was marked and measured using a Microscribe technique in 6 specimens. A 3-suture anchor repair was performed, and the area of the uncovered footprint was measured. This was repeated with traditional bone tunnel repair. For the biomechanical analysis, 8 paired specimens were randomly assigned to bone tunnel or suture anchor repair with the contralateral specimen assigned to the other technique. Each specimen underwent cyclic loading (5-25 N, 1 Hz, 100 cycles) and load to failure (15 mm/min). Displacement was measured using a digitized video recording system. Bankart repair with bone tunnels provided significantly more coverage of the native labral footprint than repair with suture anchors (100% vs 27%, P < .001). Repair with bone tunnels (21.9 ± 8.7 N/mm) showed significantly greater stiffness than suture anchor repair (17.1 ± 3.5 N/mm, P = .032). Mean load to failure and gap formation after cyclic loading were not statistically different between bone tunnel (259 ± 76.8 N, 0.209 ± 0.064 mm) and suture anchor repairs (221.5 ± 59.0 N [P = .071], 0.161 ± 0.51 mm [P = .100]). Bankart repair with bone tunnels completely covered the footprint anatomy while suture anchor repair covered less than 30% of the native footprint. Repair using bone tunnels resulted in significantly greater stiffness than repair with suture anchors. Load to failure and gap formation were not significantly different.
Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar
2014-10-01
The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent theme analysis. Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches.
Prasad, Sunil M.; Ducko, Christopher T.; Stephenson, Edward R.; Chambers, Charles E.; Damiano, Ralph J.
2001-01-01
Objective To follow up in prospective fashion patients with coronary artery anastomoses completed endoscopically with robotic assistance. The robotic system was evaluated for safety and its effectiveness in completing microsurgical coronary anastomoses. Summary Background Data Recently there has been an interest in using robotics and computers to enhance the surgeon’s ability to perform endoscopic cardiac surgery. This interest has stemmed from the rapid advancement of technology and the desire to make cardiac surgery less invasive. Using traditional endoscopic instruments, it has not been possible to perform coronary surgery. Methods Nineteen patients underwent robotically assisted endoscopic coronary artery bypass grafting of the left internal thoracic artery (LITA) to the left anterior descending artery (LAD). Two robotic instruments and one endoscopic camera were placed through three 5-mm ports. A robotic system was used to construct the LITA–LAD anastomosis. All other required grafts were completed by conventional techniques. Results Seventeen LITA–LAD grafts (89%) had adequate intraoperative flow. The mean LITA–LAD graft flow was 38.5 ± 5 mL/min. At 8 weeks, LITA–LAD grafts were assessed by angiography and showed 100% patency with thrombolysis in myocardial infarction (TIMI) I flow. At a mean follow-up of 17 ± 4.2 months, all patients were NYHA class I and there were no adverse cardiac events. Conclusions The results from the first prospective clinical trial of robotically assisted endoscopic coronary bypass surgery in the United States showed favorable short-term outcomes with no adverse events. Robotic assistance is an enabling technology allowing the performance of endoscopic coronary anastomoses. PMID:11371730
Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar
2014-01-01
Introduction The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. Materials and Methods All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent themes analysis. Results Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). Discussion The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Conclusions Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches. PMID:24533591
[A wireless power transmission system for capsule endoscope].
Xin, Wenhui; Yan, Guozheng; Wang, Wenxing
2010-06-01
In order to deliver power to the capsule endoscope, whose position and orientation are always changing when traveling along the alimentary tract, a wireless power transmission system based on electromagnetic coupling was proposed. The system is composed of Helmholtz transmitting coil and three-dimensional receiving coil. Helmholtz coil outside the body generates a uniform magnetic field covering the whole alimentary tract; three-dimensional coil inside retrieves stable power regardless of its position and orientation. The transmitter and receiver were designed and implemented, and the experiments validated the feasibility of the system. The results show that at least 320 mW of usable power can be transmitted to capsule endoscope when its position and orientation are changing at random and the transmitting power is 25W.
White, Jeremy B; Barraja, Mathieu; Mengesha, Tewodros; Bose, Sumit; Ashktorab, Samaneh; Bahn, Ryan; Vallance, Ryan; Lindsey, William H
2008-12-01
Manipulation and suspension of the superficial musculoaponeurotic system (SMAS) is performed by 74% of rhytidectomy surgeons. Multiple variations in suture techniques are employed in this task, but they have never been evaluated for differences in their ability to withstand stress. To compare the biomechanical properties of two different suture techniques that are used in SMAS plications during rhytidectomy: a double-layered running locking (DRL) stitch and multiple horizontal mattress stitches. Fourteen horizontal mattress plications, in rows of six sutures, and comparable lengths of 16 DRL stitch plications of pig skin samples, were stressed using a tensometer with grip displacement increasing at a constant rate of 0.5 cm/Min. The required force to cause plication failure was recorded for each sample at three suture break points. There was no significant difference between the two groups in the force required to cause the initial suture failure. Unlike the horizontal mattress plication, an initial break seemed to cause minimal to no distortion of the DRL tissue plication. When results were normalized by the initial break forces to account for small variations in tissue properties, the force ratio required to cause a second suture break was significantly larger in the DRL group than in the horizontal mattress technique. This is evidenced by the average second to first break force ratios of 1.62 vs. 1.13 for the DRL and horizontal mattress stitches, respectively, with a P-value of .60. The mean ratios of third to first break forces for the DRL and horizontal mattress groups were 2.08 and 0.91, respectively, with a P-value of .08. The DRL stitch requires more force than the horizontal mattress stitch to cause significant failure of tissue plication. This technique may enable plastic surgeons to avoid early revision rhytidectomy due to suture failure, and to create a long-lasting, youthful cosmetic result.
Efficiency optimization of wireless power transmission systems for active capsule endoscopes.
Zhiwei, Jia; Guozheng, Yan; Jiangpingping; Zhiwu, Wang; Hua, Liu
2011-10-01
Multipurpose active capsule endoscopes have drawn considerable attention in recent years, but these devices continue to suffer from energy limitations. A wireless power supply system is regarded as a practical way to overcome the power shortage problem in such devices. This paper focuses on the efficiency optimization of a wireless energy supply system with size and safety constraints. A mathematical programming model in which these constraints are considered is proposed for transmission efficiency, optimal frequency and current, and overall system effectiveness. To verify the feasibility of the proposed method, we use a wireless active capsule endoscope as an illustrative example. The achieved efficiency can be regarded as an index for evaluating the system, and the proposed approach can be used to direct the design of transmitting and receiving coils.
Liu, Sean Shih-Yao; Xu, Haisong; Sun, Jun; Kontogiorgos, Elias; Whittington, Patrick R; Misner, Kenner G; Kyung, Hee-Moon; Buschang, Peter H; Opperman, Lynne A
2013-08-01
Suture expansion stimulates bone growth to correct craniofacial deficiencies but has a high potential of treatment relapse. The objective of this study was to investigate whether there is a dose-dependent relationship between the recombinant human bone morphogenetic protein-2 (rhBMP-2) and bone formation during suture expansion. Fifty 6-week-old male New Zealand white rabbits were randomly assigned to 5 groups to receive 0 (control), 0.01, 0.025, 0.1, or 0.4 mg/mL of rhBMP-2 delivered by absorbable collagen sponge placed over the interfrontal suture. The suture was expanded for 33 days by 200 g of constant force via a spring anchored with 2 miniscrew implants. Distance of suture expansion, suture volume, and cross-sectional area after expansion were measured using radiographs with bone markers and microcomputed tomography. Suture widths and mineralization appositional rates were calculated based on the widths between bone labels under an epifluorescent microscope. Software (Multilevel Win 2.0; University of Bristol, Bristol, United Kingdom) was used to model distance of suture expansion over time as polynomials to compare group differences. Wilcoxon signed rank tests were performed to compare the suture volume and cross-sectional area, mineral apposition rate, and suture width between groups. The significance level was set at P = 0.05. Whereas the sutures were expanded in all groups, sutures were expanded by significantly greater amounts in the control and the 0.01 mg/mL groups without fusing the sutures than in the 0.025, 0.1, and 0.4 mg/mL groups with fusing sutures. Compared with the controls, the 0.01 mg/mL group showed significantly lower suture volumes, cross-sectional areas, and suture widths after expansion. The mineral apposition rate was significantly higher in the 0.01 mg/mL group than in the controls from days 10 to 30. The 0.01 mg/mL dose of rhBMP-2 delivered by absorbable collagen sponge can stimulate bone formation at the bony edges of the suture during suture expansion; however, higher concentrations cause suture fusion. With an appropriate concentration, rhBMP-2 might facilitate suture expansion for clinical uses. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
The Effect of Capsulotomy and Capsular Repair on Hip Distraction: A Cadaveric Investigation.
Khair, M Michael; Grzybowski, Jeffrey S; Kuhns, Benjamin D; Wuerz, Thomas H; Shewman, Elizabeth; Nho, Shane J
2017-03-01
To quantify how increasing interportal capsulotomy size affects the force required to distract the hip and to biomechanically compare simple side-to-side suture repair to acetabular-based suture anchors as capsular repair techniques. Twelve fresh-frozen cadaveric hip specimens were dissected to the capsuloligamentous complex of the hip joint and fixed in a material testing system, such that a pure axial distraction of the iliofemoral ligament could be achieved. After each hip in was tested an intact state, sequential distraction was tested with 2, 4, 6, and 8 cm capsulotomies. Specimens were assigned randomly to be repaired with either 4 side-to-side suture repair (n = 6) or 2 double-loaded all-suture anchors (n = 6). The distraction force as well as the relative distraction force percentage normalized to the intact capsule were compared between suture repair and suture anchor repair groups. Increasing the size of the capsulotomy resulted in less force required to distract the hip to 6 mm. The force decreased as the capsulotomy was extended with statistical significance in distraction force seen between the intact state and the 4 cm (P = .003), 6 cm (P < .001), and 8 cm (P ≤ .001) capsulotomy but not for the intact state compared to the 2 cm capsulotomy (P = .28). Statistical significance in relative distraction force was seen for each of the capsulotomy conditions (P < .001 for all conditions compared with the intact state). The side-to-side suture repair construct (104.3% of intact force) required greater force to distraction to 6 mm compared with the suture anchor repair (87.1% of intact force) (P = .008). An interportal capsulotomy significantly affected the force required to distract the hip in a cadaveric model, with the larger the size of capsulotomy resulting in less force required to distract the hip. When we performed an interportal capsulotomy, the iliofemoral ligament strength was altered significantly but capsular repair with either side-to-side sutures or suture anchor-based repair was able to restore the capsular strength to a native intact hip. We found, however, that the side-to-side suture repair was better able to restore the distraction force compared with suture anchor repair. Capsular management during hip arthroscopy remains a debated topic, with multiple techniques involving both capsulotomy and capsular closure published in the literature. This study provides insight into capsular stability against axial stress under capsulotomy and capsular repair conditions. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Cameron, Bruce D.; Joos, Karen M.; Shen, Jin-Hui
1996-05-01
Purpose: To develop a simple suture lysis technique for post-trabeculectomy examinations under anesthesia since slit lamp laser suture lysis in the clinic cannot be performed on infants and young children. Methods: An argon endolaser probe lysed 10-0 nylon suture through conjunctiva harvested from human cadaver eyes. Since suture lysis failed with the thick Hoskins lens, clear plastic from the suture package compressed the conjunctiva. The conjunctiva was examined histologically. Results: Argon laser suture lysis (250 mW, 0.1 sec, 488 - 514 nm) was achieved without conjunctival damage. Conclusion: The argon endolaser probe is effective for suture lysis when the slit lamp cannot be used.
Soft-light overhead illumination systems improve laparoscopic task performance.
Takai, Akihiro; Takada, Yasutsugu; Motomura, Hideki; Teramukai, Satoshi
2014-02-01
The aim of this study was to evaluate the impact of attached shadow cues for laparoscopic task performance. We developed a soft-light overhead illumination system (SOIS) that produced attached shadows on objects. We compared results using the SOIS with those using a conventional illumination system with regard to laparoscopic experience and laparoscope-to-target distances (LTDs). Forty-two medical students and 23 surgeons participated in the study. A peg transfer task (LTD, 120 mm) for students and surgeons, and a suture removal task (LTD, 30 mm) for students were performed. Illumination systems were randomly assigned to each task. Endpoints were: total number of peg transfers; percentage of peg-dropping errors; and total execution time for suture removal. After the task, participants filled out a questionnaire on their preference for a particular illumination system. Total number of peg transfers was greater with the SOIS for both students and surgeons. Percentage of peg-dropping errors for surgeons was lower with the SOIS. Total execution time for suture removal was shorter with the SOIS. Forty-five participants (69% in total) evaluated the SOIS for easier task performance. The present results confirm that the SOIS improves laparoscopic task performance, regardless of previous laparoscopic experience or LTD.
Liu, Lei; Jiang, Yunyao; Boyce, Mary; Ortiz, Christine; Baur, Jeffery; Song, Juha; Li, Yaning
2017-06-14
Irregular interdigitated morphology is prevalent in biological sutures in nature. Suture complexity index has long been recognized as the most important morphological parameter to govern the mechanical properties of biological sutures. However, the suture complexity index alone does not reflect all aspects of suture morphology. The goal of this investigation was to determine that besides suture complexity index, whether the degree of morphological irregularity of biological sutures has influences on the mechanical properties, and if there is any, how to quantify these influences. To explore these issues, theoretical and finite element (FE) suture models with the same suture complexity index but different levels of morphological irregularity were developed. The quasi-static stiffness, strength for damage initiation and post-failure process of irregular sutures were studied. It was shown that for the same suture complexity index, when the level of morphological irregularity increases, the overall strain to failure will increase while tensile stiffness is retained; also, the total energy to fracture increases with a sacrifice in strength to damage initiation. These results reveal that morphological irregularity is another important independent parameter to govern and balance the mechanical properties of biological sutures. Therefore, from the mechanics point of view, the prevalence of irregular suture morphology in nature is a merit, not a defect. Copyright © 2017 Elsevier Ltd. All rights reserved.
Virk, Mandeep S; Bruce, Benjamin; Hussey, Kristen E; Thomas, Jacqueline M; Luthringer, Tyler A; Shewman, Elizabeth F; Wang, Vincent M; Verma, Nikhil N; Romeo, Anthony A; Cole, Brian J
2017-02-01
To compare the biomechanical performance of medial row suture placement relative to the musculotendinous junction (MTJ) in a cadaveric transosseous equivalent suture bridge (TOE-SB) double-row (DR) rotator cuff repair (RCR) model. A TOE-SB DR technique was used to reattach experimentally created supraspinatus tendon tears in 9 pairs of human cadaveric shoulders. The medial row sutures were passed either near the MTJ (MTJ group) or 10 mm lateral to the MTJ (rotator cuff tendon [RCT] group). After the supraspinatus repair, the specimens underwent cyclic loading and load to failure tests. The localized displacement of the markers affixed to the tendon surface was measured with an optical tracking system. The MTJ group showed a significantly higher (P = .03) medial row failure (5/9; 3 during cyclic testing and 2 during load to failure testing) compared with the RCT group (0/9). The mean number of cycles completed during cyclic testing was lower in the MTJ group (77) compared with the RCT group (100; P = .07) because 3 specimens failed in the MTJ group during cyclic loading. There were no significant differences between the 2 study groups with respect to biomechanical properties during the load to failure testing. In a cadaveric TOE-SB DR RCR model, medial row sutures through the MTJ results in a significantly higher rate of medial row failure. In rotator cuff tears with tendon tissue loss, passage of medial row sutures through the MTJ should be avoided in a TOE-SB RCR technique because of the risk of medial row failure. Copyright © 2016. Published by Elsevier Inc.
Fluorescence endoscopic video system
NASA Astrophysics Data System (ADS)
Papayan, G. V.; Kang, Uk
2006-10-01
This paper describes a fluorescence endoscopic video system intended for the diagnosis of diseases of the internal organs. The system operates on the basis of two-channel recording of the video fluxes from a fluorescence channel and a reflected-light channel by means of a high-sensitivity monochrome television camera and a color camera, respectively. Examples are given of the application of the device in gastroenterology.
Wongkietkachorn, Apinut; Rhunsiri, Peera; Boonyawong, Pangpoom; Lawanprasert, Attaporn; Tantiphlachiva, Kasaya
2016-01-01
Tutoring in suturing was developed to compensate for a shortage of suturing cases. The objective of this study was to compare ideal suturing score (ISS; 9 points), suturing time (min:sec), and suture placement error (mm) between medical students completing the suturing tutoring program and medical students attending ordinary medical school training program. Participants consisted of 2 groups of medical students who had never performed suturing. The study group had the role of suturing tutor to teach interested high school students. The control group consisted of volunteers from the ordinary medical school program. Skills measurement was performed by having students from both the groups perform 3 vertical mattress sutures on a model. The study group was tested at weeks 1, 9, and 10 to assess improvement. Both the groups were tested at week 10 to compare final learning outcome. There were 41 and 40 participants in the study group and the control group, respectively. ISS was significantly improved in the study group from week 1-week 10 (7.0 ± 1.3 vs. 8.2 ± 0.9, p = 0.01). At week 10, the study group had a higher mean ISS than the control group (8.2 ± 0.9 vs. 7.8 ± 1.1, p = 0.68). Mean suturing time and mean placement error were also lower in the study group at the end of suturing training (5:1 ± 1:0 vs. 5:2 ± 1:2, p = 0.13; 7.4 ± 7.4 vs. 8.0 ± 10.8, p = 0.44). Tutoring trainees to suture can improve a student's ability to learn how to suture. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Nett, Michael; Avelar, Rui; Sheehan, Michael; Cushner, Fred
2011-03-01
Standard medial parapatellar arthrotomies of 10 cadaveric knees were closed with either conventional interrupted absorbable sutures (control group, mean of 19.4 sutures) or a single running knotless bidirectional barbed absorbable suture (experimental group). Water-tightness of the arthrotomy closure was compared by simulating a tense hemarthrosis and measuring arthrotomy leakage over 3 minutes. Mean total leakage was 356 mL and 89 mL in the control and experimental groups, respectively (p = 0.027). Using 8 of the 10 knees (4 closed with control sutures, 4 closed with an experimental suture), a tense hemarthrosis was again created, and iatrogenic suture rupture was performed: a proximal suture was cut at 1 minute; a distal suture was cut at 2 minutes. The impact of suture rupture was compared by measuring total arthrotomy leakage over 3 minutes. Mean total leakage was 601 mL and 174 mL in the control and experimental groups, respectively (p = 0.3). In summary, using a cadaveric model, arthrotomies closed with a single bidirectional barbed running suture were statistically significantly more water-tight than those closed using a standard interrupted technique. The sample size was insufficient to determine whether the two closure techniques differed in leakage volume after suture rupture.
The history and evolution of sutures in pelvic surgery
Muffly, Tyler M; Tizzano, Anthony P; Walters, Mark D
2011-01-01
Summary The purpose of the study is to review the history and innovations of sutures used in pelvic surgery. Based on a review of the literature using electronic- and hand-searched databases we identified appropriate articles and gynaecology surgical textbooks regarding suture for wound closure. The first documented uses of suture are explored and then the article focuses on the use of knotted materials in pelvic surgery. The development of suture of natural materials is followed chronologically until the present time where synthetic suture is implanted during countless surgeries every day. This millennial history of suture contains an appreciation of the early work of Susruta, Celsus, Paré and Lister, including a survey of some significant developments of suture methods over the last 100 years. Most surgeons know little about the history and science of sutures. A retrospective view of suture is critical to the appreciation of the current work and development of this common tool. PMID:21357979
The history and evolution of sutures in pelvic surgery.
Muffly, Tyler M; Tizzano, Anthony P; Walters, Mark D
2011-03-01
The purpose of the study is to review the history and innovations of sutures used in pelvic surgery. Based on a review of the literature using electronic- and hand-searched databases we identified appropriate articles and gynaecology surgical textbooks regarding suture for wound closure. The first documented uses of suture are explored and then the article focuses on the use of knotted materials in pelvic surgery. The development of suture of natural materials is followed chronologically until the present time where synthetic suture is implanted during countless surgeries every day. This millennial history of suture contains an appreciation of the early work of Susruta, Celsus, Paré and Lister, including a survey of some significant developments of suture methods over the last 100 years. Most surgeons know little about the history and science of sutures. A retrospective view of suture is critical to the appreciation of the current work and development of this common tool.
Takazawa, Shinya; Ishimaru, Tetsuya; Harada, Kanako; Deie, Kyoichi; Hinoki, Akinari; Uchida, Hiroo; Sugita, Naohiko; Mitsuishi, Mamoru; Iwanaka, Tadashi; Fujishiro, Jun
2018-05-01
Pediatric robot-assisted surgery is increasingly being performed, but it is difficult to perform this procedure in infants. A pediatric thoracoscopic model of a 1-year-old patient was developed in our previous study, and this model was used to evaluate the use of a surgical robot for infant surgery. Eight pediatric surgeons performed an intracorporeal suturing and knot-tying task using the da Vinci Xi Robotic Surgical System. The task completion time, number of needle manipulations, and force applied during suturing of the robot-assisted thoracoscopic surgery (RATS) group were compared with those of the video-assisted thoracoscopic surgery (VATS) group whose data had been collected from the same 8 surgeons in our previous study. The RATS group showed a significantly shorter completion time than the VATS group in the knot-tying phase (P = .016) and in the total phase (P = .0078). The RATS group showed a significantly smaller number of manipulations than the VATS group in the total phase (P = .039). The RATS group showed a significantly smaller pushing force index than the VATS group in the suturing phase (P = .031), knot-tying phase (P = .031), and in the total phase (P = .031). A seventh rib in the model was dislocated in all RATS group cases. The da Vinci Surgical System might be useful in infants because of fast movement and small pushing force. However, the robotic 8 mm instruments were too large for use in the thoracic cavity of the 1-year-old infant.
Nadler, Robert B; Perry, Kent T; Smith, Norm D
2009-07-01
To describe a clampless approach made possible by creating an avascular plane of tissue with radiofrequency ablation. Laparoscopic partial nephrectomy is slowly gaining acceptance as a method to treat small (<4 cm) and select moderate (<7 cm) renal masses. The intricacies of laparoscopic suturing, which result in prolonged warm ischemia times, have delayed the widespread acceptance of this technique among urologists. Laparoscopic suturing to close the collecting system was done using the da Vinci robot. An avascular plane of tissue from coagulation necrosis was achieved with the Habib 4X radiofrequency ablation device and the Rita 1500X generator. Typically, we used a power setting of 50 W but have found settings as low as 25 W necessary to provide hemostasis for larger vessels. The tumor was then sharply excised with a negative margin using robotic scissors and electrocautery to facilitate tissue cutting. Retrograde injection of methylthioninium chloride and saline through an externalized ureteral catheter allowed for precise sutured closure of the collecting system. FloSeal and BioGlue were then applied, making surgical bolsters or parenchymal sutures unnecessary. Intraoperative histologic evaluation of the surgical margin and repeat resection of the tumor bed was possible because the renal hilum was not clamped, and no warm ischemia was used. This technique, which combines the improving technologies of robotic surgery, intraoperative laparoscopic ultrasonography, and radiofrequency ablation, might make more surgeons comfortable with the intricacies of laparoscopic suturing and eliminate prolonged warm ischemia times. Overall, this method should result in more patients being able to undergo minimally invasive laparoscopic partial nephrectomy.
Effects of Visual Force Feedback on Robot-Assisted Surgical Task Performance
Reiley, Carol E.; Akinbiyi, Takintope; Burschka, Darius; Chang, David C.; Okamura, Allison M.; Yuh, David D.
2009-01-01
Background Direct haptic (force or tactile) feedback is negligible in current surgical robotic systems. The relevance of haptic feedback in robot-assisted performances of surgical tasks is controversial. We studied the effects of visual force feedback (VFF), a haptic feedback surrogate, on tying surgical knots with fine sutures similar to those used in cardiovascular surgery. Methods Using a modified da Vinci robotic system (Intuitive Surgical, Inc.) equipped with force-sensing instrument tips and real-time VFF overlays in the console image, ten surgeons each tied 10 knots with and 10 knots without VFF. Four surgeons had significant prior da Vinci experience while the remaining six surgeons did not. Performance parameters, including suture breakage and secure knots, peak and standard deviation of applied forces, and completion times using 5-0 silk sutures were recorded. Chi-square and Student’s t-test analyses determined differences between groups. Results Among surgeon subjects with robotic experience, no differences in measured performance parameters were found between robot-assisted knot ties executed with and without VFF. Among surgeons without robotic experience, however, VFF was associated with lower suture breakage rates, peak applied forces, and standard deviations of applied forces. VFF did not impart differences in knot completion times or loose knots for either surgeon group. Conclusions VFF resulted in reduced suture breakage, lower forces, and decreased force inconsistencies among novice robotic surgeons, although elapsed time and knot quality were unaffected. In contrast, VFF did not affect these metrics among experienced da Vinci surgeons. These results suggest that VFF primarily benefits novice robot-assisted surgeons, with diminishing benefits among experienced surgeons. PMID:18179942
Kang, Han Gyu; Lee, Ho-Young; Kim, Kyeong Min; Song, Seong-Hyun; Hong, Gun Chul; Hong, Seong Jong
2017-01-01
The aim of this study is to integrate NIR, gamma, and visible imaging tools into a single endoscopic system to overcome the limitation of NIR using gamma imaging and to demonstrate the feasibility of endoscopic NIR/gamma/visible fusion imaging for sentinel lymph node (SLN) mapping with a small animal. The endoscopic NIR/gamma/visible imaging system consists of a tungsten pinhole collimator, a plastic focusing lens, a BGO crystal (11 × 11 × 2 mm 3 ), a fiber-optic taper (front = 11 × 11 mm 2 , end = 4 × 4 mm 2 ), a 122-cm long endoscopic fiber bundle, an NIR emission filter, a relay lens, and a CCD camera. A custom-made Derenzo-like phantom filled with a mixture of 99m Tc and indocyanine green (ICG) was used to assess the spatial resolution of the NIR and gamma images. The ICG fluorophore was excited using a light-emitting diode (LED) with an excitation filter (723-758 nm), and the emitted fluorescence photons were detected with an emission filter (780-820 nm) for a duration of 100 ms. Subsequently, the 99m Tc distribution in the phantom was imaged for 3 min. The feasibility of in vivo SLN mapping with a mouse was investigated by injecting a mixture of 99m Tc-antimony sulfur colloid (12 MBq) and ICG (0.1 mL) into the right paw of the mouse (C57/B6) subcutaneously. After one hour, NIR, gamma, and visible images were acquired sequentially. Subsequently, the dissected SLN was imaged in the same way as the in vivo SLN mapping. The NIR, gamma, and visible images of the Derenzo-like phantom can be obtained with the proposed endoscopic imaging system. The NIR/gamma/visible fusion image of the SLN showed a good correlation among the NIR, gamma, and visible images both for the in vivo and ex vivo imaging. We demonstrated the feasibility of the integrated NIR/gamma/visible imaging system using a single endoscopic fiber bundle. In future, we plan to investigate miniaturization of the endoscope head and simultaneous NIR/gamma/visible imaging with dichroic mirrors and three CCD cameras. © 2016 American Association of Physicists in Medicine.
Güleçyüz, Mehmet F; Mazur, Alexandra; Schröder, Christian; Braun, Christian; Ficklscherer, Andreas; Roßbach, Björn P; Müller, Peter E; Pietschmann, Matthias F
2015-06-01
The purpose of this study was to analyze the biomechanical integrity of suture anchors of different materials (titanium, PEEK [polyether ether ketone], poly-L-lactic acid [PLLA], and β-tricalcium phosphate PLLA) and almost identical design for rotator cuff repair in human humeri positioned in a water bath at room and body temperature undergoing cyclic loading rather than single-pull or static tests. Four different anchor models (n = 6) were tested using healthy human cadaveric humeri in a water bath thermostatically regulated at 20°C and 37°C. A cyclic testing protocol was used. The maximum failure load, the system displacement, and the respective mode of failure were recorded. There were no significant differences regarding the maximum failure load values between the 20°C groups and 37°C groups for the 4 different anchor materials. The displacement values for the 20°C groups and 37°C groups also were not statistically significant. Anchor and suture dislocations were the predominant modes of failure; suture ruptures were observed in few cases. This study shows that there are no significantly relevant differences regarding the maximum failure loads and the displacement values of the tested suture anchor systems in a wet environment at 20°C or 37°C. The temperature differences do not seem to affect the modes of failure either. Titanium, PEEK, PLLA, and β-tricalcium phosphate PLLA suture anchors for rotator cuff repair can be expected-on the basis of this investigation comparing laboratory temperature with body temperature and a wet environment-to perform in vivo similar to in vitro testing. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Endoscopic Optical Coherence Tomography for Clinical Gastroenterology
Tsai, Tsung-Han; Fujimoto, James G.; Mashimo, Hiroshi
2014-01-01
Optical coherence tomography (OCT) is a real-time optical imaging technique that is similar in principle to ultrasonography, but employs light instead of sound waves and allows depth-resolved images with near-microscopic resolution. Endoscopic OCT allows the evaluation of broad-field and subsurface areas and can be used ancillary to standard endoscopy, narrow band imaging, chromoendoscopy, magnification endoscopy, and confocal endomicroscopy. This review article will provide an overview of the clinical utility of endoscopic OCT in the gastrointestinal tract and of recent achievements using state-of-the-art endoscopic 3D-OCT imaging systems. PMID:26852678
Capsule endoscope localization based on computer vision technique.
Liu, Li; Hu, Chao; Cai, Wentao; Meng, Max Q H
2009-01-01
To build a new type of wireless capsule endoscope with interactive gastrointestinal tract examination, a localization and orientation system is needed for tracking 3D location and 3D orientation of the capsule movement. The magnetic localization and orientation method produces only 5 DOF, but misses the information of rotation angle along capsule's main axis. In this paper, we presented a complementary orientation approach for the capsule endoscope, and the 3D rotation can be determined by applying computer vision technique on the captured endoscopic images. The experimental results show that the complementary orientation method has good accuracy and high feasibility.
Suture Products and Techniques: What to Use, Where, and Why.
Regula, Christie G; Yag-Howard, Cyndi
2015-10-01
There are an increasing number of wound closure materials and suturing techniques described in the dermatologic and surgery literature. A dermatologic surgeon's familiarity with these materials and techniques is important to supplement his or her already established practices and improve surgical outcomes. To perform a thorough literature review of wound closure materials (sutures, tissue adhesives, surgical tape, and staples) and suturing techniques and to outline how and when to use them. A literature review was conducted using PubMed and other online search engines. Keywords searched included suture, tissue adhesive, tissue glue, surgical tape, staples, dermatologic suturing, and suturing techniques. Numerous articles outline the utility of various sutures, surgical adhesives, surgical tape, and staples in dermatologic surgery. In addition, there are various articles describing classic and novel suturing techniques along with their specific uses in cutaneous surgery. Numerous factors must be considered when choosing a wound closure material and suturing technique. These include wound tension, desire for wound edge eversion/inversion, desired hemostasis, repair type, patient's ability to care for the wound and return for suture removal, skin integrity, and wound location. Careful consideration of these factors and proper execution of suturing techniques can lead to excellent cosmetic results.
Cho, Byung-Ki; Kim, Yong-Min; Kim, Dong-Soo; Choi, Eui-Sung; Shon, Hyun-Chul; Park, Kyoung-Jin
2013-01-01
The present prospective, randomized study was conducted to compare the clinical outcomes of the modified Brostrom procedure using single and double suture anchors for chronic lateral ankle instability. A total of 50 patients were followed up for more than 2 years after undergoing the modified Brostrom procedure. Of the 50 procedures, 25 each were performed using single and double suture anchors by 1 surgeon. The Karlsson scale had improved significantly to 89.8 points and 90.6 points in the single and double anchor groups, respectively. Using the Sefton grading system, 23 cases (92%) in the single anchor group and 22 (88%) in the double anchor group achieved satisfactory results. The talar tilt angle and anterior talar translation on stress radiographs using the Telos device had improved significantly to an average of 5.7° and 4.6 mm in the single anchor group and 4.5° and 4.3 mm in the double anchor group, respectively. The double anchor technique was superior with respect to the postoperative talar tilt. The single and double suture anchor techniques produced similar clinical and functional outcomes, with the exception of talar tilt as a reference of mechanical stability. The modified Brostrom procedure using both single and double suture anchors appears to be an effective treatment method for chronic lateral ankle instability. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Integrated endoscopic OCT system and in-vivo images of human internal organs
NASA Astrophysics Data System (ADS)
Sergeev, Alexander M.; Gelikonov, Valentin M.; Gelikonov, Grigory V.; Feldchtein, Felix I.; Kuranov, Roman V.; Gladkova, Natalia D.; Shakhova, Natalia M.; Snopova, Ludmila; Shakhov, Andrei; Kuznetzova, Irina N.; Denisenko, Arkady; Pochinko, Vitaly; Chumakov, Yuri; Almasov, Valentin
1998-04-01
First results of endoscopic applications of optical coherence tomography (OCT) for in vivo studies of human mucosa in respiratory, gastrointestinal, urinary and genital tracts are presented. A novel endoscopic OCT (EOCT) system has been created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, larynx, stomach, urinary bladder, uterine cervix and endometrium as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancered tissue is distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.
Lee, Jun; Kim, Dong-Min; Yun, Na Ra; Kim, Young Dae; Park, Chan Guk; Kim, Man Woo
2016-01-01
Scrub typhus is an infectious disease caused by Orientia tsutsugamushi-induced systemic vasculitis, but the involvement of the gastrointestinal tract and the endoscopic findings associated with scrub typhus are not well understood. We performed a prospective study and recommend performing esophagogastroduodenoscopy (EGD) for all possible scrub typhus patients, regardless of gastrointestinal symptoms. Gastrointestinal symptoms, endoscopic findings and clinical severity based on organ involvement and ICU admission were analyzed. Gastrointestinal symptoms occurred in up to 76.4% of scrub typhus patients. The major endoscopic findings were ulcers (43/127, 33.9%). Interestingly, 7.1% (9/127) of the patients presented with esophageal candidiasis. There was no correlation between the presence or absence of gastrointestinal symptoms and the endoscopic grade (P = 0.995). However, there was a positive correlation between the clinical severity and the endoscopic findings (P = 0.001). Sixty-three percent of the patients presented with erosion or ulcers on prospectively performed endoscopic evaluations, irrespective of gastrointestinal symptoms. Gastrointestinal symptoms did not reflect the need for endoscopy. Scrub typhus patients could have significant endoscopic abnormalities even in the absence of gastrointestinal symptoms. PMID:27195943
Suture material in bladder surgery: a comparison of polydioxanone, polyglactin, and chromic catgut.
Stewart, D W; Buffington, P J; Wacksman, J
1990-06-01
A comparison of polydioxanone, polyglactin, and chromic catgut suture was performed in 120 rat bladders studying propensity for infection, degree of inflammation, calculogenic potential, changes in urine pH, and suture absorption. None of the sutures predisposed to infection and there was wide variability but no correlation in urine pH. Although initially the polydioxanone incited a greater inflammatory response, by six months all three sutures were similar. The absorption of polydioxanone was slower than chromic catgut suture, but similar to the absorption of polyglactin. There was no significant difference in calculogenic potential between the suture materials tested over a six-month period. Based on this study in rats, polydioxanone suture would appear to be equal to catgut and polyglactin suture in bladder surgery.
Storch, Mark; Scalzo, Howard; Van Lue, Stephen; Jacinto, Gabriel
2002-01-01
The goal of this study was to compare the physical and functional properties of coated polyglactin 910 suture with and without triclosan by human assessment and instrument-based measurements. Surgeons specializing in general, orthopedic, plastic, or gynecologic surgery evaluated the suture materials in an in vivo porcine model with regard to (1) ease of passage through tissue, (2) first-throw knot holding, (3) knot tie-down smoothness, (4) knot security, (5) surgical handling, and (6) overall evaluation. Breaking strength retention was determined at 14, 21, 28, and 35 days post-implantation in rats using a tensile strength measurement device. The absorption rate was determined in rats by histopathology at 7, 28, 56, 63, 70, and 77 days post-implantation. The tactile smoothness and tie-down behavior of both wet and dry sutures were evaluated by product characterization technicians. The scores for surgeons' evaluation of suture material were favorable and similar for both sutures. Surgeons could not reliably make a distinction in handling between the two sutures. Breaking strength retention was the same for both sutures, ranging from 79% on day 14 to 5% on day 35. Both sutures were essentially absorbed at 70 days post-implantation. Product characterization assessment of the two sutures found them to be indistinguishable. The addition of triclosan to coated polyglactin 910 sutures did not affect physical handling properties or performance characteristics based on the testing and evaluations performed.
Woo, Shanan; Walklin, Ryan; Ackermann, Travis; Lo, Sheng Wei; Shilton, Hamish; Pilgrim, Charles; Evans, Peter; Burnes, James; Croagh, Daniel
2018-05-10
Primary endoscopic and percutaneous drainage for pancreatic necrotic collections is increasingly used. We aim to compare the relative effectiveness of both modalities in reducing the duration and severity of illness by measuring their effects on systemic inflammatory response syndrome (SIRS). We retrospectively reviewed all cases of endoscopic and percutaneous drainage for pancreatic necrotic collections performed in 2011-2016 at two hospitals. We assessed the post-procedure length of hospital stay, reduction in C-reactive protein levels, resolution of SIRS, the complication rates, and the number of procedures required for resolution. Thirty-two patients were identified and 57 cases (36 endoscopic, 21 percutaneous) were included. There was no significant difference in C-reactive protein reduction between endoscopic and percutaneous drainage (69.5% vs 68.8%, P = 0.224). Resolution of SIRS was defined as the post-procedure normalization of white cell count (endoscopic vs percutaneous: 70.4% vs 64.3%, P = 0.477), temperature (endoscopic vs percutaneous: 93.3% vs 60.0%, P = 0.064), heart rate (endoscopic vs percutaneous: 56.0% vs 11.1%, P = 0.0234), and respiratory rate (endoscopic vs percutaneous: 83.3% vs 0.0%, P = 0.00339). Post-procedure length of hospital stay was 27 days with endoscopic drainage and 46 days with percutaneous drainage (P = 0.0183). Endoscopic drainage was associated with a shorter post-procedure length of hospital stay and a greater rate of normalization of SIRS parameters than percutaneous drainage, although only the effects on heart rate and respiratory rate reached statistical significance. Further studies are needed to establish which primary drainage modality is superior for pancreatic necrotic collections. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
Ultra-high definition (8K UHD) endoscope: our first clinical success.
Yamashita, Hiromasa; Aoki, Hisae; Tanioka, Kenkichi; Mori, Toshiyuki; Chiba, Toshio
2016-01-01
We have started clinical application of 8K ultra-high definition (UHD; 7680 × 4320 pixels) imaging technology, which is a 16-fold higher resolution than the current 2K high-definition (HD; 1920 × 1080 pixels) technology, to an endoscope for advanced laparoscopic surgery. Based on preliminary testing experience and with subsequent technical and system improvements, we then proceeded to perform two cases of cholecystectomy and were able to achieve clinical success with an 8K UHD endoscopic system, which consisted of an 8K camera, a 30-degrees angled rigid endoscope with a lens adapter, a pair of 300-W xenon light sources, an 85-inch 8K LCD and an 8K video recorder. These experimental and clinical studies revealed the engineering and clinical feasibility of the 8K UHD endoscope, enabling us to have a positive outlook on its prospective use in clinical practice. The 8K UHD endoscopy promises to open up new possibilities for intricate procedures including anastomoses of thin nerves and blood vessels as well as more confident surgical resections of a diversity of cancer tissues. 8K endoscopic imaging, compared to imaging by the current 2K imaging technology, is very likely to lead to major changes in the future of medical practice.
Systems workplace for endoscopic surgery.
Irion, K M; Novak, P
2000-01-01
With the advent of minimally invasive surgery (MIS) a decade ago, the requirements for operating rooms (OR) and their equipment have been increased. Compared with conventional open surgery, the new endoscopic techniques require additional tools. Television systems, for video-assisted image acquisition and visualisation, including cameras, monitors and light systems, as well as insufflators, pumps, high-frequency units, lasers and motorised therapy units, are nowadays usually made available on carts during endoscopic surgery. In conjunction with a set of endoscopic instruments, these high-tech units allow new operating techniques to be performed. The benefit for patients has become clear in recent years; however, the technical complexity of OR has also increased considerably. To minimise this problem for the OR personnel, the MIS concept 'OR1' (Operating Room 1) was developed and implemented. OR1 is a fully functional and integrated multi-speciality surgical suite for MIS. The centrepieces of the OR1 are the Storz Communication Bus (SCB) and the advanced image and data archiving system (Aida) from Karl Storz, Tuttlingen, Germany. Both components allow monitoring, access and networking of the MIS equipment and other OR facilities, as well as the acquisition, storage and display of image, patient and equipment data during the endoscopic procedure. A central user interface allows efficient, simplified operation and online clinical images. Due to the system integration, the handling of complex equipment is considerably simplified, logistical procedures in the OR are improved, procedure times are shorter and, particularly noteworthy, operative risk can be reduced through simplified device operation.
Jacobi, C A; Junghans, T; Peter, F; Naundorf, D; Ordemann, J; Müller, J M
2000-11-01
Injury of venous vessels during elevated intraperitoneal pressure is thought to cause possible fatal gas embolism, and helium may be dangerous because of its low solubility. Twenty pigs underwent laparoscopy with either CO2 (n=10) or helium (n=10) with a pressure of 15 mm Hg and standardized laceration (1 cm) of the vena cava inferior. After 30 s, the vena cava was clamped, closed endoscopically by a running suture and unclamped again. During the procedure changes of cardiac output (CO), heart rate (HR), mean arterial pressure (MAP), central venous pressure (CVP), pulmonary artery pressure (PAP), pulmonary artery wedge pressure (PAWP), end tidal CO2 pressure (PETCO2), and arterial blood gas analyses (pH, pO2 and pCO2) were investigated. No animal died during the experimental course (mean blood loss during laceration: CO2, 157+/-50 ml; helium, 173+/-83 ml). MAP and CO values showed a decrease after laceration of the vena cava in both groups that had already been completely compensated for before suturing. PETCO2 increased significantly after CO2 insufflation (P<0.01), while helium showed no effect. Laceration of the vena cava caused no significant changes in PETCO2 values in either group. Significant acidosis and an increase of pCO2 were only found in the CO2 group. The incidence of gas embolism during laparoscopy and accidental vessel injury seems to be very low. With the exception of acidosis and an increase of PETCO2 in the CO2 group, there were no differences in cardiopulmonary function between insufflation of CO2 and helium.
Kim, Anthony W; Liptay, Michael J; Snow, Norman; Donahue, Philip; Warren, William H
2008-06-01
The objective of this study was to review the clinical experience of temporarily placing an endoesophageal silicone salivary bypass stent and its value in managing patients with life-threatening esophageal disruptions. Clinical records of patients undergoing placement of silicone Montgomery salivary bypass stents from June 1998 to September 2007 were reviewed. Seventeen patients had a proven esophageal disruption in the absence of malignancy and with life-threatening sepsis refractory to conventional management. Underlying conditions were iatrogenic trauma from prior pulmonary surgery (4 patients), significant anastomotic leaks after an esophagogastrectomy (4 patients), delayed presentation (> 24 hours) of a perforated esophagus (4 patients), leak after esophageal surgery (3 patients), and esophagobronchial fistula secondary to inflammation and infection (2 patients). Stents were placed without securing, were sutured in place to the esophageal wall at the time of thoracotomy, or were secured by bringing holding sutures through the nostrils and tied over the bridge of the nose. In all cases, placement of the esophageal stent led to prompt improvement of the leak and, within a week, improvement of the sepsis. Supportive measures were continued after placement of the stent. Sixteen patients overcame the sepsis with ultimate healing of the esophageal disruption (13 patients) or maturation of the perforation into a chronic fistula (3 patients). Endoscopic stent removal was performed 2 to 16 weeks after placement. No patient had a stricture develop at the disruption site. One patient died of ruptured thoracic aorta. Silicone salivary bypass stents serve as an effective way of diverting and excluding the oral-alimentary stream, thereby providing optimal conditions for sepsis control. They are a useful adjunct in the management of complex esophageal conditions.
NASA Astrophysics Data System (ADS)
Vega, David; Kiekens, Kelli C.; Syson, Nikolas C.; Romano, Gabriella; Baker, Tressa; Barton, Jennifer K.
2018-02-01
While Optical Coherence Microscopy (OCM), Multiphoton Microscopy (MPM), and narrowband imaging are powerful imaging techniques that can be used to detect cancer, each imaging technique has limitations when used by itself. Combining them into an endoscope to work in synergy can help achieve high sensitivity and specificity for diagnosis at the point of care. Such complex endoscopes have an elevated risk of failure, and performing proper modelling ensures functionality and minimizes risk. We present full 2D and 3D models of a multimodality optical micro-endoscope to provide real-time detection of carcinomas, called a salpingoscope. The models evaluate the endoscope illumination and light collection capabilities of various modalities. The design features two optical paths with different numerical apertures (NA) through a single lens system with a scanning optical fiber. The dual path is achieved using dichroic coatings embedded in a triplet. A high NA optical path is designed to perform OCM and MPM while a low NA optical path is designed for the visible spectrum to navigate the endoscope to areas of interest and narrowband imaging. Different tests such as the reflectance profile of homogeneous epithelial tissue were performed to adjust the models properly. Light collection models for the different modalities were created and tested for efficiency. While it is challenging to evaluate the efficiency of multimodality endoscopes, the models ensure that the system is design for the expected light collection levels to provide detectable signal to work for the intended imaging.
Takeuchi, Masaki
2013-01-01
Background: This study describes the use of a bioabsorbable suture for skin suturing during surgery for lateral ray polydactyly followed by favorable postoperative outcome without the need for postoperative suture removal. Methods: A 5-0 Vicryl Rapide suture was used for skin suturing during surgery for lateral ray polydactyly in 9 children (mean age, 12.4 mo). Children were allowed to walk and bathe 2 weeks after surgery when over-the-suture taping therapy was started. Results: In all cases, the Vicryl Rapide suture disappeared completely within 3 weeks of surgery, and no removal of residual suture was required. No postoperative complications, such as suture abscess, wound dehiscence, or ulcer, were observed. During a mean 24-month postoperative follow-up, no elevation of the interdigital space due to hypertrophic scarring or scar contracture was observed, and no revision surgery was required. Conclusions: Although the breaking strength of Vicryl Rapide declines within the first 10 days after surgery, this property will unlikely lead to postoperative wound dehiscence due to a relatively light load being applied to the lateral toes. The use of a bioabsorbable suture for skin suturing during surgery for lateral lay polydactyly is highly beneficial as it eliminates pain caused by suture removal and the risk of tissue damage while reducing the burden on medical staff. PMID:25289236
Hunziker, Manuela; Mohanan, Nochiparambil; Puri, Prem
2013-05-01
Endoscopic subureteral injection of dextranomer/hyaluronic acid has become an established alternative to long-term antibiotic prophylaxis or surgical treatment for vesicoureteral reflux. We evaluated the effectiveness of endoscopic injection of dextranomer/hyaluronic acid in intermediate and high grade vesicoureteral reflux in patients with complete duplex collecting systems. A total of 123 children underwent endoscopic correction of intermediate or high grade vesicoureteral reflux using injection of dextranomer/hyaluronic acid into complete duplex systems between 2001 and 2010. Vesicoureteral reflux was diagnosed by voiding cystourethrogram, and dimercapto-succinic acid scan was performed to evaluate the presence of renal scarring. Followup ultrasound and voiding cystourethrogram were performed 3 months after the outpatient procedure and renal ultrasound thereafter every 2 years. Mean followup was 6.7 years. Complete duplex systems were unilateral in 110 patients and bilateral in 13. Reflux severity in the 136 refluxing units was grade II in 1 (0.7%), III in 52 (38.2%), IV in 61 (44.9%) and V in 22 (16.2%). Dimercapto-succinic acid scan revealed renal functional abnormalities in 63 children (51.2%). Vesicoureteral reflux resolved after the first endoscopic injection of dextranomer/hyaluronic acid in 93 ureters (68.4%), after a second injection in 35 (25.7%) and after a third injection in 8 (5.9%). Febrile urinary tract infection developed in 5 patients (4.1%) during followup. No patient required ureteral reimplantation or experienced significant complications. Our results confirm the safety and efficacy of endoscopic injection of dextranomer/hyaluronic acid in eradicating intermediate and high grade vesicoureteral reflux in patients with complete duplex systems. We recommend this minimally invasive, 15-minute outpatient procedure as a viable option for treating intermediate and high grade vesicoureteral reflux in patients with complete duplex collecting systems. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Surgeon-Directed Cost Variation in Isolated Rotator Cuff Repair.
Terhune, E Bailey; Cannamela, Peter C; Johnson, Jared S; Saad, Charles D; Barnes, John; Silbernagel, Janette; Faciszewski, Thomas; Shea, Kevin G
2016-12-01
As value becomes a larger component of heath care decision making, cost data can be evaluated for regional and physician variation. Value is determined by outcome divided by cost, and reducing cost increases value for patients. "Third-party spend" items are individual selections by surgeons used to perform procedures. Cost data for third-party spend items provide surgeons and hospitals with important information regarding care value, potential cost-saving opportunities, and the total cost of ownership of specific clinical decisions. To perform a cost review of isolated rotator cuff repair within a regional 7-hospital system and to document procedure cost variation among operating surgeons. Economic and decision analysis; Level of evidence, 4. Current Procedural Terminology (CPT) codes were used to retrospectively identify subjects who received an isolated rotator cuff repair within a 7-hospital system. Cost data were collected for clinically sensitive third-party spend items and divided into 4 cost groups: (1) suture anchors, (2) suture-passing devices and needles, (3) sutures used for cuff repair, and (4) disposable tools or instruments. A total of 62 isolated rotator cuff repairs were performed by 17 surgeons over a 13-month period. The total cost per case for clinically sensitive third-party spend items (in 2015 US dollars) ranged from $293 to $3752 (mean, $1826). Four surgeons had a mean procedure cost that was higher than the data set mean procedure cost. The cost of an individual suture anchor ranged from $75 to $1775 (mean, $403). One disposable suture passer was used, which cost $140. The cost of passing needles ranged from $140 to $995 (mean, $468). The cost per repair suture (used to repair cuff tears) varied from $18 to $298 (mean, $61). The mean suture (used to close wounds) cost per case was $81 (range, $0-$454). A total of 316 tools or disposable instruments were used, costing $1 to $1573 per case (mean, $624). This study demonstrates significant cost variation with respect to cost per case and cost of individual items used during isolated rotator cuff repair. Suture anchors represent the most expensive and variable surgeon-directed cost. The wide cost variation seen in all cost categories illustrates both the effect of surgeon choice in procedure cost and the opportunity for significant cost savings in cases of isolated rotator cuff repair. Engaging surgeons in discussion on cost can positively influence the value of care provided to patients if costs can be reduced without affecting the quality of patient outcomes.
Kreeft, Davey; Arkenbout, Ewout Aart; Henselmans, Paulus Wilhelmus Johannes; van Furth, Wouter R.; Breedveld, Paul
2017-01-01
A clear visualization of the operative field is of critical importance in endoscopic surgery. During surgery the endoscope lens can get fouled by body fluids (eg, blood), ground substance, rinsing fluid, bone dust, or smoke plumes, resulting in visual impairment. As a result, surgeons spend part of the procedure on intermittent cleaning of the endoscope lens. Current cleaning methods that rely on manual wiping or a lens irrigation system are still far from ideal, leading to longer procedure times, dirtying of the surgical site, and reduced visual acuity, potentially reducing patient safety. With the goal of finding a solution to these issues, a literature review was conducted to identify and categorize existing techniques capable of achieving optically clean surfaces, and to show which techniques can potentially be implemented in surgical practice. The review found that the most promising method for achieving surface cleanliness consists of a hybrid solution, namely, that of a hydrophilic or hydrophobic coating on the endoscope lens and the use of the existing lens irrigation system. PMID:28511635
Capelli, Claudio; Corsini, Chiara; Biscarini, Dario; Ruffini, Francesco; Migliavacca, Francesco; Kocher, Alfred; Laufer, Guenther; Taylor, Andrew M; Schievano, Silvia; Andreas, Martin; Burriesci, Gaetano; Rath, Claus
2017-03-01
Surgical aortic valve replacement is the most common procedure of choice for the treatment of severe aortic stenosis. Bioprosthetic valves are traditionally sewed-in the aortic root by means of pledget-armed sutures during open-heart surgery. Recently, novel bioprostheses which include a stent-based anchoring system have been introduced to allow rapid implantation, therefore reducing the duration and invasiveness of the intervention. Different effects on the hemodynamics were clinically reported associated with the two technologies. The aim of this study was therefore to investigate whether the differences in hemodynamic performances are an effect of different anchoring systems. Two commercially available bio-prosthetic aortic valves, one sewed-in with pledget-armed sutures and one rapid-deployment, were thus tested in this study by means of a combined approach of experimental and computational tools. In vitro experiments were performed to evaluate the overall hydrodynamic performance under identical standard conditions; computational fluid dynamics analyses were set-up to explore local flow variations due to different design of the anchoring system. The results showed how the performance of cardiac valve substitutes is negatively affected by the presence of pledget-armed sutures. These are causing flow disturbances, which in turn increase the mean pressure gradient and decrease the effective orifice area. The combined approach of experiments and numerical simulations can be effectively used to quantify the detailed relationship between local fluid-dynamics and overall performances associated with different valve technologies.
Esposito, Felice; Di Rocco, Federico; Zada, Gabriel; Cinalli, Giuseppe; Schroeder, Henry W S; Mallucci, Conor; Cavallo, Luigi M; Decq, Philippe; Chiaramonte, Carmela; Cappabianca, Paolo
2013-12-01
During the past decade, endoscopic intraventricular and skull base operations have become widely used for a variety of evolving indications. A global survey of practicing endoscopic neurosurgeons was performed to characterize patterns of usage regarding endoscopy equipment, instrumentation, and the indications for using image-guided surgery systems (IGSs). An online survey consisting of 8 questions was completed by 235 neurosurgeons with endoscopic surgical experience. Responses were entered into a database and subsequently analyzed. The median number of operations performed per year by intraventricular and skull base endoscopic surgeons was 27 and 25, respectively. Data regarding endoscopic equipment brand, diameter, and length are presented. The most commonly reported indications for IGSs during intraventricular endoscopic surgery were tumor biopsy/resection, intraventricular cyst fenestration, septostomy/pellucidotomy, endoscopic third ventriculostomy, and aqueductal stent placement. Intraventricular surgeons reported using IGSs for all cases in 16.6% and never in 24.4%. Overall, endoscopic skull base surgeons reported using IGSs for all cases in 23.9% and never in 18.9%. The most commonly reported indications for IGSs during endoscopic skull base operations were complex sinus/skull base anatomy, extended approaches, and reoperation. Many variations and permutations for performing intraventricular and skull base endoscopic surgery exist worldwide. Much can be learned by studying the patterns and indications for using various types of equipment and operative adjuncts such as IGSs. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Shih-Wei; Chen, Shih-Hua; Chen, Weichung; Wu, I.-Chen; Wu, Ming Tsang; Kuo, Chie-Tong; Wang, Hsiang-Chen
2016-03-01
This study presents a method to identify early esophageal cancer within endoscope using hyperspectral imaging technology. The research samples are three kinds of endoscopic images including white light endoscopic, chromoendoscopic, and narrow-band endoscopic images with different stages of pathological changes (normal, dysplasia, dysplasia - esophageal cancer, and esophageal cancer). Research is divided into two parts: first, we analysis the reflectance spectra of endoscopic images with different stages to know the spectral responses by pathological changes. Second, we identified early cancerous lesion of esophagus by principal component analysis (PCA) of the reflectance spectra of endoscopic images. The results of this study show that the identification of early cancerous lesion is possible achieve from three kinds of images. In which the spectral characteristics of NBI endoscopy images of a gray area than those without the existence of the problem the first two, and the trend is very clear. Therefore, if simply to reflect differences in the degree of spectral identification, chromoendoscopic images are suitable samples. The best identification of early esophageal cancer is using the NBI endoscopic images. Based on the results, the use of hyperspectral imaging technology in the early endoscopic esophageal cancer lesion image recognition helps clinicians quickly diagnose. We hope for the future to have a relatively large amount of endoscopic image by establishing a hyperspectral imaging database system developed in this study, so the clinician can take this repository more efficiently preliminary diagnosis.
Lien, Gi-Shih; Liu, Chih-Wen; Jiang, Joe-Air; Chuang, Cheng-Long; Teng, Ming-Tsung
2012-07-01
This paper presents a novel solution of a hand-held external controller to a miniaturized capsule endoscope in the gastrointestinal (GI) tract. Traditional capsule endoscopes move passively by peristaltic wave generated in the GI tract and the gravity, which makes it impossible for endoscopists to manipulate the capsule endoscope to the diagnostic disease areas. In this study, the main objective is to present an endoscopic capsule and a magnetic field navigator (MFN) that allows endoscopists to remotely control the locomotion and viewing angle of an endoscopic capsule. The attractive merits of this study are that the maneuvering of the endoscopic capsule can be achieved by the external MFN with effectiveness, low cost, and operation safety, both from a theoretical and an experimental point of view. In order to study the magnetic interactions between the endoscopic capsule and the external MFN, a magnetic-analysis model is established for computer-based finite-element simulations. In addition, experiments are conducted to show the control effectiveness of the MFN to the endoscopic capsule. Finally, several prototype endoscopic capsules and a prototype MFN are fabricated, and their actual capabilities are experimentally assessed via in vitro and ex vivo tests using a stomach model and a resected porcine stomach, respectively. Both in vitro and ex vivo test results demonstrate great potential and practicability of achieving high-precision rotation and controllable movement of the capsule using the developed MFN.
Zorn, Kevin C; Trinh, Quoc-Dien; Jeldres, Claudio; Schmitges, Jan; Widmer, Hugues; Lattouf, Jean-Baptiste; Sammon, Jesse; Liberman, Dan; Sun, Maxine; Bianchi, Marco; Karakiewicz, Pierre I; Denis, Ronald; Gautam, Gagan; El-Hakim, Assaad
2012-05-01
Study Type - RCT (randomized trial) Level of Evidence 2b. What's known on the subject? and What does the study add? In a previous randomized controlled trial, barbed polyglyconate suture for vesico-urethral anastomosis was associated with more frequent cystogram leaks, longer mean catheterization times and greater suture costs per case. In the current randomized controlled trial, we show that barbed polyglyconate suture is associated with decreased anastomosis time, decreased need to readjust suture tension, cost reduction, and equal continence and early/late urinary complication rates. To examine the effectiveness of barbed polyglyconate suture (V-Loc 180; Covidien, Mansfield, MA, USA) compared with standard monofilament for posterior reconstruction (PR) and vesico-urethral anastomosis (VUA) during robot-assisted radical prostatectomy (RARP). A prospective randomized controlled trial was conducted in 70 consecutive RARP cases by a single surgeon (K.C.Z.). Standard VUA was performed using three 4-0 poliglecaprone 25 (Monocryl; Ethicon Endosurgery, Cincinnati, OH, USA) sutures secured with absorbable suture clips (LapraTy, Ethicon; one single 6-inch [15.2 cm] for PR and two attached 6-inch [15.2 cm] for VUA). Barbed suture VUA was performed using two 3-0 6-inch (15.2 cm) barbed polyglyconate sutures. Time to complete the suture set-up by the nursing team, anastomosis time and need to adjust suture tension were recorded. Suture-related complications, validated-questionnaire continence and cost were also examined. Compared with a conventional reconstruction technique, there was a significant reduction in mean nurse set-up time (31 vs. 294 s; P < 0.01) and reconstruction time (13.1 vs. 20.8 min; P < 0.01) for the barbed suture technique. Need to readjust suture tension or to place additional suture clips for watertight closure was greater in the standard monofilament group than in the barbed suture group (6% vs. 24%; P= 0.03). • A cost reduction was recorded at our institution (48.05 vs. 70.25 $CAN) with the barbed suture technique. • With a mean follow-up of 6.2 months, no delayed anastomotic leak or bladder neck contracture was observed in either group. • Pad-free continence outcomes for the monofilament suture vs the barbed suture groups at 1 (64 vs. 69%, P= 0.6), 3 (76 vs. 81%, P= 0.5) and 6 months (88 vs. 92%, P= 0.7) were similar. • Compared with standard monofilament suture, the unidirectional barbed polyglyconate suture appears to provide safe, efficient and cost-effective PR and VUA during RARP. • Use of the interlocked barbed polyglyconate suture technique prevents slippage, precluding the need for assistance, knot-tying and constant reassessment of anastomosis integrity. © 2012 THE AUTHORS. BJU INTERNATIONAL © 2012 BJU INTERNATIONAL.
Suture cost savings in the OR.
Walsh, Susanna S
2012-05-01
Materials management personnel at a health care facility in Baltimore, Maryland, were stocking too much suture. They stocked suture requested by surgeons or recommended by suture company representatives, and, because the facility is a teaching institution, they stocked suture requested by residents. No master suture database was available to determine what was needed and what was not. As a result, some suture was rarely used, which cost the facility money and took up inventory space. In response, I created a list of the existing inventory and coordinated with the specialty surgical service coordinators to determine which suture was typically used and in what quantities. I used this information to create a master list, with the goal of eliminating the purchase of suture that was not on this list. I gave the staff members and surgeons two months to assess the list and determine whether the suggested suture was sufficient for their needs. I then asked the materials management personnel to order and maintain suture stock based on the master list. This process took approximately four months and shows how health care providers can take a high-volume item, such as suture, and create cost-saving processes that will serve surgeons' and patients' needs while reducing costs and streamlining stock. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Analysis of suture anchor eyelet position on suture failure load.
Aktay, Sevima A; Kowaleski, Michael P
2011-06-01
To compare mechanical performance of 2 orientations of the 5 mm Corkscrew® suture anchor with #5 Fiberwire® . In vitro biomechanical study. Suture anchor-suture constructs (n=40). Acute and cyclic tensile loads were applied to suture threaded through eyelets of 40 anchors perpendicular to the long axis of the anchor. Eyelets were positioned so that the suture pull was in line with (anchor rotation angle of 0° [ARA 0]) or 90° (ARA 90) to the eyelet plane. Load at failure, stiffness, and cycles to failure were determined. All constructs failed by suture breakage at the eyelet. Mean load at failure was significantly higher in the ARA 90 group (634 ± 93 N) compared with the ARA 0 group (495 ± 52 N; P=.0015). No significant difference was found between groups for mean number of cycles to failure (270 ± 177 versus 178 ± 109; P=.2166) and stiffness (50 ± 4 versus 48 ± 5 N/mm; P=.3141). The Corkscrew® 5 mm suture anchor with Fiberwire® suture fails via suture breakage at the eyelet under higher acute loads if the suture is loaded at an angle of 90° compared with 0° with respect to the plane of the eyelet. © Copyright 2011 by The American College of Veterinary Surgeons.
NASA Astrophysics Data System (ADS)
Lytwyn, Jennifer; Burke, Kevin; Culver, Stephen
2006-12-01
The boundaries of the West African Craton mark the location of a continuous suture zone that records Neoproterozoic to Early Cambrian oceanic closure. The western part of the circum-West African suture zone extends through the line of outcrop of the Mauritanide, Bassaride and Rokelide mountain belts. Our geochemical analyses are consistent with the idea that igneous and metamorphic rocks of the Rokelide and Southern Mauritanide mountain belts of West Africa occupy a suture zone that records the closing of a Neoproterozoic to Early Cambrian ocean basin during the Pan-African orogeny and final assembly of Gondwana. The closing of that basin was marked by the collision between Archean rocks of the Leo massif of the West African Craton and reactivated Archean and Paleoproterozoic rocks that now outcrop nearer to the coast of Africa in Sierra Leone and Liberia. Within the Rokelides, the geochemistry of the Kasewe Hills volcanic rocks and Marampa amphibolite indicate that remnants of an arc system are caught up in the suture zone. The geochemistry of Guingan schists that outcrop along strike of the Rokelides is compatible with the idea that the metamorphosed equivalents of the Marampa and Kasewe Hills arc volcanic rocks extend through the Bassarides and into the Southern Mauritanides.
Different Sutures in the Surgical Treatment of Acute Closed Achilles Tendon Rupture.
Ji, Yunhan; Ma, Xin; Wang, Xu; Huang, Jiazhang; Zhang, Chao; Chen, Li
2015-12-01
The aim was to compare the postoperative efficacy of the PDS II and Ethibond W4843 sutures in fresh, closed Achilles tendon rupture. With methods of random grouping (level of evidence II b), a total of 128 patients with fresh Achilles tendon rupture were operated on with PDS II or Ethibond W4843 suture. Postoperative objective examination and the American Orthopaedic Foot & Ankle Society (AOFAS) scoring system were used for the evaluation. Group A underwent 12-39 months of follow-up, for an average of 22 months. Group B underwent 12-37 months of follow-up, for an average of 23 months. The postoperative AOFAS score of group A within 3 months was 93 ± 9.6 points. One case exhibited re-rupture, five cases exhibited incision infection, one case manifested deep infection, and seven cases exhibited Achilles tendon adhesion. The postoperative AOFAS score of group B within 3 months was 97 ± 7.8 points. Eleven cases had incision infection, and 13 cases manifested Achilles tendon adhesion. Minimal differences were observed in the incision infection, re-rupture rate, and Achilles tendon adhesion in the study of the PDS II and Ethibond W4843 sutures. But, based on the AOFAS score and pain score, the Ethibond suture performed better.
Perez-Blanca, Ana; Prado Nóvoa, María; Lombardo Torre, Maximiano; Espejo-Reina, Alejandro; Ezquerro Juanco, Francisco; Espejo-Baena, Alejandro
2018-04-01
To assess the role of suture cutout in the mechanics of failure of the repaired posterior meniscal root during the early post-operative period when using sutures of different shape. Twenty medial porcine menisci were randomized in two groups depending on the suture shape used to repair the posterior root: thread or tape. The sutured menisci were subjected to cyclic loading (1000 cycles, (10, 30) N) followed by load-to-failure testing. Residual displacements, stiffness, and ultimate failure load were determined. During tests, the tissue-suture interface was recorded using a high-resolution camera. In cyclic tests, cutout progression at the suture insertion points was not observed for any specimen of either group and no differences in residual displacements were found between use of thread or tape. In load-to-failure tests, suture cutout started in all menisci at a load close to the ultimate failure and all specimens failed by suture pullout. Suture tape had a greater ultimate load with no other differences. In a porcine model of a repaired posterior meniscal root subjected to cyclic loads representative of current rehabilitation protocols in the early post-operative period under restricted loading conditions, suture cutout was not found as a main source of permanent root displacement when using suture thread or tape. Suture cutout progression started at high loading levels close to the ultimate load of the construct. Tape, with a meniscus-suture contact area larger than thread, produced higher ultimate load.
Cranial suture biology of the Aleutian Island inhabitants.
Cray, James; Mooney, Mark P; Siegel, Michael I
2011-04-01
Research on cranial suture biology suggests there is biological and taxonomic information to be garnered from the heritable pattern of suture synostosis. Suture synostosis along with brain growth patterns, diet, and biomechanical forces influence phenotypic variability in cranial vault morphology. This study was designed to determine the pattern of ectocranial suture synostosis in skeletal populations from the Aleutian Islands. We address the hypothesis that ectocranial suture synostosis pattern will differ according to cranial vault shape. Ales Hrdlicka identified two phenotypes in remains excavated from the Aleutian Island. The Paleo-Aleutians, exhibiting a dolichocranic phenotype with little prognathism linked to artifacts distinguished from later inhabitants, Aleutians, who exhibited a brachycranic phenotype with a greater amount of prognathism. A total of 212 crania representing Paleo-Aleuts and Aleutian as defined by Hrdlicka were investigated for suture synostosis pattern following standard methodologies. Comparisons were performed using Guttmann analyses. Results revealed similar suture fusion patterns for the Paleo-Aleut and Aleutian, a strong anterior to posterior pattern of suture fusion for the lateral-anterior suture sites, and a pattern of early termination at the sagittal suture sites for the vault. These patterns were found to differ from that reported in the literature. Because these two populations with distinct cranial shapes exhibit similar patterns of suture synostosis it appears pattern is independent of cranial shape in these populations of Homo sapiens. These findings suggest that suture fusion patterns may be population dependent and that a standardized methodology, using suture fusion to determine age-at-death, may not be applicable to all populations. Copyright © 2011 Wiley-Liss, Inc.
Younesi, Mousa; Knapik, Derrick M; Cumsky, Jameson; Donmez, Baris Ozgur; He, Ping; Islam, Anowarul; Learn, Greg; McClellan, Philip; Bohl, Michael; Gillespie, Robert J; Akkus, Ozan
2017-11-01
Flexor tendon lacerations are traditionally repaired by using non-absorbable monofilament sutures. Recent investigations have explored to improve the healing process by growth factor delivery from the sutures. However, it is difficult to conjugate growth factors to nylon or other synthetic sutures. This study explores the performance of a novel electrochemically aligned collagen suture in a flexor tendon repair model with and without platelet derived growth factor following complete tendon laceration in vivo. Collagen suture was fabricated via electrochemical alignment process. Heparin was covalently bound to electrochemically aligned collagen sutures (ELAS) to facilitate affinity bound delivery of platelet-derived growth factor-BB (PDGF-BB). Complete laceration of the flexor digitorum profundus in the third digit of the foot was performed in 36 skeletally mature White Leghorn chickens. The left foot was used as the positive control. Animals were randomly divided into three groups: control specimens treated with standard nylon suture (n=12), specimens repaired with heparinated ELAS suture without PDGF-BB (n=12) and specimens repaired with heparinated ELAS suture with affinity bound PDGF-BB (n=12). Specimens were harvested at either 4weeks or 12weeks following tendon repair. Differences between groups were evaluated by the degree of gross tendon excursion, failure load/stress, stiffness/modulus, absorbed energy at failure, elongation/strain at failure. Quantitative histological scoring was performed to assess cellularity and vascularity. Closed flexion angle measurements demonstrated no significant differences in tendon excursion between the study groups at 4 or 12weeks. Biomechanical testing showed that the group treated with PDGF-BB bound heparinated ELAS suture had significantly higher stiffness and failure load (p<0.05) at 12-weeks relative to both heparinated ELAS suture and nylon suture. Similarly, the group treated with PDGF-BB bound suture had significantly higher ultimate tensile strength and Young's modulus (p<0.05) at 12-weeks relative to both ELAS suture and nylon suture. Compared to nylon controls, heparinized ELAS with PDGF-BB improved biomechanics and vascularity during tendon healing by 12-weeks following primary repair. The ability of ELAS to deliver PDGF-BB to the lacerated area of tendon presents investigators with a functional bioinductive platform to improve repair outcomes following flexor tendon repair. A high strength aligned collagen suture was fabricated via linear electrocompaction and heparinized for prolonged delivery of PDFG-BB. When it was used to suture a complete lacerated flexor tendon in a chicken model controlled release of the PDGF-BB improved the strength of treated tendon after 12 weeks compared to tendon sutured with commercial nylon suture. Furthermore, Collagen suture with affinity bound PDGF-BB enhanced the vascularization and remodeling of lacerated tendon when it compare to synthetic nylon suture. Overall, electrocompacted collagen sutures holds potential to improve repair outcome in flexor tendon surgeries by improving repair strength and stiffness, vascularity, and remodeling via sustained delivery of the PDGF-BB. The bioinductive collagen suture introduces a platform for sustained delivery of other growth factors for a wide-array of applications. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Design of signal reception and processing system of embedded ultrasonic endoscope
NASA Astrophysics Data System (ADS)
Li, Ming; Yu, Feng; Zhang, Ruiqiang; Li, Yan; Chen, Xiaodong; Yu, Daoyin
2009-11-01
Embedded Ultrasonic Endoscope, based on embedded microprocessor and embedded real-time operating system, sends a micro ultrasonic probe into coelom through the biopsy channel of the Electronic Endoscope to get the fault histology features of digestive organs by rotary scanning, and acquires the pictures of the alimentary canal mucosal surface. At the same time, ultrasonic signals are processed by signal reception and processing system, forming images of the full histology of the digestive organs. Signal Reception and Processing System is an important component of Embedded Ultrasonic Endoscope. However, the traditional design, using multi-level amplifiers and special digital processing circuits to implement signal reception and processing, is no longer satisfying the standards of high-performance, miniaturization and low power requirements that embedded system requires, and as a result of the high noise that multi-level amplifier brought, the extraction of small signal becomes hard. Therefore, this paper presents a method of signal reception and processing based on double variable gain amplifier and FPGA, increasing the flexibility and dynamic range of the Signal Reception and Processing System, improving system noise level, and reducing power consumption. Finally, we set up the embedded experiment system, using a transducer with the center frequency of 8MHz to scan membrane samples, and display the image of ultrasonic echo reflected by each layer of membrane, with a frame rate of 5Hz, verifying the correctness of the system.
[Manual suture versus/or mechanical suture from the Austrian viewpoint].
Kronberger, L; Germann, R
1987-01-01
A general inquiry was made at surgical units and university clinics in Austria about the anastomosis techniques used between 1980 to 1985. The result was that in 90.3% the suture was made by hand and in 9.7% by machine. The first mentioned was performed as double row inverting suture by 66% of our surgeons, and only in 30% as an all-layer suture. The stapler-technique was mostly preferred for the oesophago-jejunostomy and the high and lower resection of the rectum. A leakage of the suture line was observed in 3.9% after sewing by hand and in 6.3% after stapling. The total lethality finally was 1.4% for hand made suture and 1.8% for apparative suture.
Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.
Hayeri, Mohammad Reza; Keefe, Daniel T; Chang, Eric Y
2016-05-01
Rotator cuff repair using a suture bridge and knotless suture anchors is a relatively new, but increasingly used technique. The suture bridge technique creates an anatomically similar and more secure rotator cuff repair compared with conventional arthroscopic techniques and the use of knotless anchors eliminates the challenges associated with knot tying during arthroscopic surgery. However, previous in vitro biomechanical tests have shown that the hold of the suture in a knotless suture anchor is far lower than the pullout strength of the anchor from bone. Up until now slippage has been a theoretical concern. We present a prospectively diagnosed case of in vivo suture loosening after rotator cuff repair using a knotless bridge technique resulting in subacromial-subdeltoid bursitis.
NASA Astrophysics Data System (ADS)
Wall, R. Andrew; Barton, Jennifer K.
2014-06-01
A side-viewing, 2.3-mm diameter oblique incidence reflectometry endoscope has been designed to obtain optical property measurements of turbid samples. Light from a single-mode fiber is relayed obliquely onto the tissue with a gradient index lens-based distal optics assembly and the resulting diffuse reflectance profile is imaged and collected with a 30,000 element, 0.72 mm clear aperture fiber bundle. Sampling the diffuse reflectance in two-dimensions allows for fitting of the reflected intensity profile to a well-known theoretical model, permitting the extraction of both absorption and reduced scattering coefficients of the tissue sample. Models and measurements of the endoscopic imaging system are presented in tissue phantoms and in vivo mouse colon, verifying the endoscope's capabilities to accurately measure effective attenuation coefficient and differentiate diseased from normal colon.
[Percutaneous endoscopic gastrostomy].
Kuz'min-Krutetskiĭ, M I; Demko, A E; Safoev, A I; Akkalaeva, A É; Karimova, L I
2014-01-01
The percutaneous endoscopic gastrostomy takes an important place in operative endoscopy of the digestive system. At the same time it is the method of choice in patients who need a long-term administration of enteral feeding. Given article reflects the main indications, contraindications and complications of the percutaneous endoscopic gastrostomy and presents the basic stages of the method. The authors hope, that the data would be useful for both entry-lever surgeon-endoscopists and specialists who used the method.
High Resolution Sub-MM Fiberoptic Endoscope Final Report CRADA No. TSB-1447-97
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, Gary F.; Smith, John
2018-01-22
At the time of the CRADA, LLNL needed to develop a sub-mm outer diameter fiberoptic endoscope with 25pm or better resolution at 3-lOmm working distance to support the Enhanced Surveillance Program (ESP) and the Core Surveillance Program for DOE. The commercially available systems did not meet the image resolution requirements and development work was needed to reach three goals. We also needed to perform preliminary investigations into the production of such an endoscope with a steerable-articulated distal end. The goal of such an endoscope was to allow for a 45 degree inspection cone including the lens field of view.
Correction of rotational distortion for catheter-based en face OCT and OCT angiography
Ahsen, Osman O.; Lee, Hsiang-Chieh; Giacomelli, Michael G.; Wang, Zhao; Liang, Kaicheng; Tsai, Tsung-Han; Potsaid, Benjamin; Mashimo, Hiroshi; Fujimoto, James G.
2015-01-01
We demonstrate a computationally efficient method for correcting the nonuniform rotational distortion (NURD) in catheter-based imaging systems to improve endoscopic en face optical coherence tomography (OCT) and OCT angiography. The method performs nonrigid registration using fiducial markers on the catheter to correct rotational speed variations. Algorithm performance is investigated with an ultrahigh-speed endoscopic OCT system and micromotor catheter. Scan nonuniformity is quantitatively characterized, and artifacts from rotational speed variations are significantly reduced. Furthermore, we present endoscopic en face OCT and OCT angiography images of human gastrointestinal tract in vivo to demonstrate the image quality improvement using the correction algorithm. PMID:25361133
Results from the commissioning of a multi-modal endoscope for ultrasound and time of flight PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bugalho, Ricardo
2015-07-01
The EndoTOFPET-US collaboration has developed a multi-modal imaging system combining Ultrasound with Time-of-Flight Positron Emission Tomography into an endoscopic imaging device. The objective of the project is to obtain a coincidence time resolution of about 200 ps FWHM and to achieve about 1 mm spatial resolution of the PET system, while integrating all the components in a very compact detector suitable for endoscopic use. This scanner aims to be exploited for diagnostic and surgical oncology, as well as being instrumental in the clinical test of new biomarkers especially targeted for prostate and pancreatic cancer. (authors)
Zheng, B; Denk, P M; Martinec, D V; Gatta, P; Whiteford, M H; Swanström, L L
2008-04-01
Complex laparoscopic tasks require collaboration of surgeons as a surgical team. Conventionally, surgical teams are formed shortly before the start of the surgery, and team skills are built during the surgery. There is a need to establish a training simulation to improve surgical team skills without jeopardizing the safety of surgery. The Legacy Inanimate System for Laparoscopic Team Training (LISETT) is a bench simulation designed to enhance surgical team skills. The reported project tested the construct validity of LISETT. The research question was whether the LISETT scores show progressive improvement correlating with the level of surgical training and laparoscopic team experience or not. With LISETT, two surgeons are required to work closely to perform two laparoscopic tasks: peg transportation and suturing. A total of 44 surgical dyad teams were recruited, composed of medical students, residents, laparoscopic fellows, and experienced surgeons. The LISETT scores were calculated according to the speed and accuracy of the movements. The LISETT scores were positively correlated with surgical experience, and the results can be generalized confidently to surgical teams (Pearson's coefficient, 0.73; p = 0.001). To analyze the influences of individual skill and team dynamics on LISETT performance, team quality was rated by team members using communication and cooperation characters after each practice. The LISETT scores are positively correlated with self-rated team quality scores (Pearson's coefficient, 0.39; p = 0.008). The findings proved LISETT to be a valid system for assessing cooperative skills of a surgical team. By increasing practice time, LISETT provides an opportunity to build surgical team skills, which include effective communication and cooperation.
Zellner, Eric M; Hedlund, Cheryl S; Kraus, Karl H; Burton, Andrew F; Kieves, Nina R
2016-06-15
OBJECTIVE To compare suture placement time, tension at skin separation and suture line failure, and mode of failure among 4 suture patterns. DESIGN Randomized trial. SAMPLE 60 skin specimens from the pelvic limbs of 30 purpose-bred Beagles. PROCEDURES Skin specimens were harvested within 2 hours after euthanasia and tested within 6 hours after harvest. An 8-cm incision was made in each specimen and sutured with 1 of 4 randomly assigned suture patterns (simple interrupted, cruciate, intradermal, or subdermal). Suture placement time and percentage of skin apposition were evaluated. Specimens were mounted in a calibrated material testing machine and distracted until suture line failure. Tensile strength at skin-edge separation and suture-line failure and mode of failure were compared among the 4 patterns. RESULTS Mean suture placement time for the cruciate pattern was significantly less than that for other patterns. Percentage of skin apposition did not differ among the 4 patterns. Mean tensile strength at skin-edge separation and suture-line failure for the simple interrupted and cruciate patterns were significantly higher than those for the intradermal and subdermal patterns. Mean tensile strength at skin-edge separation and suture-line failure did not differ significantly between the intradermal and subdermal patterns or the simple interrupted and cruciate patterns. The primary mode of failure for the simple interrupted pattern was suture breakage, whereas that for the cruciate, intradermal, and subdermal patterns was tissue failure. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested external skin sutures may be preferred for closure of incisions under tension to reduce risk of dehiscence.
de Carvalho, Marcus Vinicius H.; Marchi, Evaldo; Lourenço, Edmir Américo
2017-01-01
Introduction Tissue adhesives can be used as adjacent to sutures to drop or avoid bleeding in cardiovascular operations. Objective To verify the efficiency of fibrin and cyanoacrylate adhesive to seal arterial sutures and if the adhesives penetrate through suture line to the inner of arteries. Methods 20 abdominal aorta segments of pigs were divided into two groups according to the adhesive which would be used as adjacent to the suture. In every arterial segment an arteriotomy was done, followed by a conventional artery closure. Afterwards a colloidal fluid was injected inside the arterial segment with a simultaneous intravascular pressure monitoring up to a fluid leakage through the suture. This procedure was repeated after application of one of the adhesives on the suture in order to check if the bursting pressure increases. The inner aorta segments also were analyzed in order to check if there was intraluminal adhesive penetration. Results In Suture 1 group, the mean arterial pressure sustained by the arterial suture reached 86±5.35 mmHg and after the fibrin adhesive application reached 104±11.96 (P<0.002). In the Suture 2 group, the mean arterial pressure sustained by the suture reached 83±2.67 mmHg and after the cyanoacrylate adhesive application reached 152±14.58 mmHg (P<0.002). Intraluminal adhesive penetration has not been noticed. Conclusion There was a significant rise in the bursting pressure when tissue adhesives were used as adjacent to arterial suture, and this rise was higher if the cyanoacrylate adhesive was used. In addition, the adhesives do not penetrate through the suture line into the arteries. PMID:29267611
Sasaki, Gordon H; Cohen, Andrew T
2002-08-01
The aging anterior midface is restored by reversing the contour undulations produced by sagging of the malar fat pad complex toward the nasolabial line. The convex irregularities include the exposed bulges of the post-septal fat, the unveiled malar bag, and the prominent nasolabial fold. The depressed irregularities are represented by the cresent-shaped hollow at the lid-cheek junction, the accentuated nasojugal groove, and the deepening nasolabial line. Repositioning of the ptotic malar fat pad, among other elements of meloplasty, represents a key procedure. In this study, the malar fat pad has been defined as a fan-shaped structure by external anatomic landmarks that correlate closely to the findings in cadaveric dissections and clinical cases, confirmed by the findings of spiral computed tomographic scanning. A simple but powerful adjustable and long-lasting percutaneous suture elevation technique was developed over the past 6 years by the senior author (G.H.S.) to reposition the fat pad in a superolateral direction. Through a dot incision within the nasolabial line, a permanent CV-3 Gore-Tex (or 4-0 clear Prolene) suspension suture, looped through a Gore-Tex anchor graft, suspends the malar fat pad in a direction perpendicular to the nasolabial line. A second suspension system is identically passed through another lower dot incision to broaden the repositioning vectors on the malar fat pad. Tension on each of the paired suture ends elevates the malar fat pad by 1 to 3 mm as measured from the nasolabial dot incisions. The sutures are fixed to the deep temporal fascia through a Gore-Tex tab, effectively stabilizing the soft-tissue repositioning. This maneuver may be performed in younger patients who present with an isolated malar fat pad ptosis without excess facial skin. The procedure may also be incorporated into open rhytidectomies to address this recalcitrant area along with superficial musculoaponeurotic system tightening. A total of 392 patients since 1995 underwent suture elevation of the malar fat pads. An outcome study indicated that the usage of two permanent sutures with Gore-Tex anchor grafts since 1998 resulted in improvement in midface rejuvenation of over 82 percent. Early and late complication rates were small and temporary. Patient acceptance was excellent, indicative of the benefits of anatomic repositioning of the malar fat pad complex.
Comparison of completely knotless and hybrid double-row fixation systems: a biomechanical study.
Chu, Thomas; McDonald, Erik; Tufaga, Michael; Kandemir, Utku; Buckley, Jenni; Ma, C Benjamin
2011-04-01
The purpose of this study was to compare the biomechanical performance of a completely knotless double-row repair system (SutureCross Knotless Anatomic Fixation System; KFx Medical, Carlsbad, CA) with 2 commonly used hybrid double-row repair (medial knot-tying, lateral knotless) systems (Bio-Corkscrew/PushLock [Arthrex, Naples, FL] and Spiralok/Versalok [DePuy Mitek, Raynham, MA]). Fourteen pairs of fresh-frozen cadaveric shoulders were harvested, the supraspinatus tendons were isolated, and full-thickness supraspinatus tears were created. One of each pair was repaired with the completely knotless system, and the contralateral side was repaired with either of the hybrid systems. The repairs were then subjected to cyclic loading followed by load to failure. Conditioning elongation, peak-to-peak elongation, ultimate load, and mechanism of failure were recorded and compared by use of paired t tests. Seven additional shoulders were tested to determine the effect of refrigeration storage on the completely knotless system by use of the same mechanical testing protocol. For the completely knotless repair group, 11 of 14 paired specimens failed during the cyclic loading period. Only 1 of 14 hybrid repair systems had failures during cyclic loading, and both hybrid repair systems had statistically lower conditioning elongation than the completely knotless repair group. The mean ultimate load of the SutureCross group was 166 ± 87 N, which was significantly lower than that in the Corkscrew/PushLock (310 ± 82 N) and Spiralok/Versalok (337 ± 44 N) groups. There was an effect of refrigeration storage on the peak-to-peak elongation and stiffness of the SutureCross group; however, there was no difference in ultimate tensile load or conditioning elongation. The completely knotless repair system has lower time-zero biomechanical properties than the other 2 hybrid systems. The SutureCross system has lower time-zero biomechanical properties when compared with other hybrid repair systems. Clinical outcome studies are needed to determine the significance. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Current manufacturing processes of drug-eluting sutures.
Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine
2017-11-01
Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.
Zhang, Gangqiang; Ren, Tianhui; Lette, Walter; Zeng, Xiangqiong; van der Heide, Emile
2017-10-01
Nowadays there is a wide variety of surgical sutures available in the market. Surgical sutures have different sizes, structures, materials and coatings, whereas they are being used for various surgeries. The frictional performances of surgical sutures have been found to play a vital role in their functionality. The high friction force of surgical sutures in the suturing process may cause inflammation and pain to the person, leading to a longer recovery time, and the second trauma of soft or fragile tissue. Thus, the investigation into the frictional performance of surgical suture is essential. Despite the unquestionable fact, little is actually known on the friction performances of surgical suture-tissue due to the lack of appropriate test equipment. This study presents a new penetration friction apparatus (PFA) that allowed for the evaluation of the friction performances of various surgical needles and sutures during the suturing process, under different contact conditions. It considered the deformation of tissue and can realize the puncture force measurements of surgical needles as well as the friction force of surgical sutures. The developed PFA could accurately evaluate and understand the frictional behaviour of surgical suture-tissue in the simulating clinical conditions. The forces measured by the PFA showed the same trend as that reported in literatures. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I
2011-01-01
Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology. PMID:21385182
Endoscope disinfection and its pitfalls--requirement for retrograde surveillance cultures.
Buss, A J; Been, M H; Borgers, R P; Stokroos, I; Melchers, W J; Peters, F T; Limburg, A J; Degener, J E
2008-04-01
Several endoscopy-related outbreaks of infection have been reported in recent years. For early recognition of inadequate disinfection of endoscopes we designed a microbiological surveillance system to evaluate the efficacy of the cleaning and disinfection procedure, and to trace disinfection problems to individual endoscopes or washer-disinfectors. Our surveillance protocol included anterograde and retrograde sampling, a decision algorithm, genetic fingerprinting, and scanning electron microscopy. Over a period of 29 months we found an increasing number of patient-ready endoscopes testing positive for Candida species other than albicans, especially C. parapsilosis. These yeasts were also isolated from the washer-disinfectors. The number of positive tests for Candida species varied from 1 out of 21 to 14 out of 27 samples from nine frequently used endoscopes. The number of colony-forming units per milliliter ranged from 1 - 10 to 3000 for endoscopes and 0.002 to 0.06 for the washer disinfectors. DNA fingerprinting was not able to discriminate different strains within C. parapsilosis. Our protocol was able to detect a structural problem in the endoscope disinfection process. Retrograde sampling was crucial for this purpose, because it has much higher sensitivity than anterograde sampling. Endoscopes with damaged working channels are probably the source of the contamination problem with Candida species.
Feasibility of Piezoelectric Endoscopic Transsphenoidal Craniotomy: A Cadaveric Study
Tomazic, Peter Valentin; Gellner, Verena; Koele, Wolfgang; Hammer, Georg Philipp; Braun, Eva Maria; Gerstenberger, Claus; Clarici, Georg; Holl, Etienne; Braun, Hannes; Stammberger, Heinz; Mokry, Michael
2014-01-01
Objective. Endoscopic transsphenoidal approach has become the gold standard for surgical treatment of treating pituitary adenomas or other lesions in that area. Opening of bony skull base has been performed with burrs, chisels, and hammers or standard instruments like punches and circular top knives. The creation of primary bone flaps—as in external craniotomies—is difficult.The piezoelectric osteotomes used in the present study allows creating a bone flap for endoscopic transnasal approaches in certain areas. The aim of this study was to prove the feasibility of piezoelectric endoscopic transnasal craniotomies. Study Design. Cadaveric study. Methods. On cadaveric specimens (N = 5), a piezoelectric system with specially designed hardware for endonasal application was applied and endoscopic transsphenoidal craniotomies at the sellar floor, tuberculum sellae, and planum sphenoidale were performed up to a size of 3–5 cm2. Results. Bone flaps could be created without fracturing with the piezoosteotome and could be reimplanted. Endoscopic handling was unproblematic and time required was not exceeding standard procedures. Conclusion. In a cadaveric model, the piezoelectric endoscopic transsphenoidal craniotomy (PETC) is technically feasible. This technique allows the surgeon to create a bone flap in endoscopic transnasal approaches similar to existing standard transcranial craniotomies. Future trials will focus on skull base reconstruction using this bone flap. PMID:24689037
Wang, Caixia; Chen, Yuanyuan; Yang, Feng; Ren, Jie; Yu, Xin; Wang, Jiani; Sun, Siyu
2016-08-01
The present study aimed to assess the efficacy of computer-based endoscope cleaning and disinfection using a hospital management information system (HMIS). A total of 2,674 gastroscopes were eligible for inclusion in this study. For the processes of disinfection management, the gastroscopes were randomly divided into 2 groups: gastroscope disinfection HMIS (GD-HMIS) group and manual group. In the GD-HMIS group, an integrated circuit card (IC card) chip was installed to monitor and record endoscope cleaning and disinfection automatically and in real time, whereas the endoscope cleaning and disinfection in the manual group was recorded manually. The overall disinfection progresses for both groups were recorded, and the total operational time was calculated. For the GD-HMIS group, endoscope disinfection HMIS software was successfully developed. The time to complete a single session of cleaning and disinfecting on a gastroscope was 15.6 minutes (range, 14.3-17.2 minutes) for the GD-HMIS group and 21.3 minutes (range, 20.2-23.9 minutes) for the manual group. Failure to record information, such as the identification number of the endoscope, occasionally occurred in the manual group, which affected the accuracy and reliability of manual recording. Computer-based gastroscope cleaning and disinfection using a hospital management information system could monitor the process of gastroscope cleaning and disinfection in real time and improve the accuracy and reliability, thereby ensuring the quality of gastroscope cleaning and disinfection. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Video and accelerometer-based motion analysis for automated surgical skills assessment.
Zia, Aneeq; Sharma, Yachna; Bettadapura, Vinay; Sarin, Eric L; Essa, Irfan
2018-03-01
Basic surgical skills of suturing and knot tying are an essential part of medical training. Having an automated system for surgical skills assessment could help save experts time and improve training efficiency. There have been some recent attempts at automated surgical skills assessment using either video analysis or acceleration data. In this paper, we present a novel approach for automated assessment of OSATS-like surgical skills and provide an analysis of different features on multi-modal data (video and accelerometer data). We conduct a large study for basic surgical skill assessment on a dataset that contained video and accelerometer data for suturing and knot-tying tasks. We introduce "entropy-based" features-approximate entropy and cross-approximate entropy, which quantify the amount of predictability and regularity of fluctuations in time series data. The proposed features are compared to existing methods of Sequential Motion Texture, Discrete Cosine Transform and Discrete Fourier Transform, for surgical skills assessment. We report average performance of different features across all applicable OSATS-like criteria for suturing and knot-tying tasks. Our analysis shows that the proposed entropy-based features outperform previous state-of-the-art methods using video data, achieving average classification accuracies of 95.1 and 92.2% for suturing and knot tying, respectively. For accelerometer data, our method performs better for suturing achieving 86.8% average accuracy. We also show that fusion of video and acceleration features can improve overall performance for skill assessment. Automated surgical skills assessment can be achieved with high accuracy using the proposed entropy features. Such a system can significantly improve the efficiency of surgical training in medical schools and teaching hospitals.
Yoon, Seung Bae; Lee, In Seok; Lee, Ha Ni; Kim, Eunyoung; Kim, Woohyeon; Lee, Han Hee; Lee, Bo-In; Choi, Myung-Gyu; Jung, Seung Eun; Choi, Byung Ock; Park, Gyeong Sin; Cho, Seok-Goo
2016-09-01
According to lymphoma guidelines, gastric diffuse large B cell lymphoma (DLBCL) patients should undergo regular computed tomography (CT) and/or positron emission tomography (PET) examinations to assess treatment response. Endoscopic examinations are not indicated in the guidelines. The aim of this study was to investigate the utility of endoscopic examinations during and after treatment for DLBCL. We reviewed the patients diagnosed with gastric DLBCL at Seoul St. Mary's Hospital. All patients underwent endoscopy and radiologic examinations at every follow-up appointment. Radiologic response was defined according to World Health Organization criteria and endoscopic response was determined based on the Groupe d'Etude des Lymphomes de l'Adult grading system that is widely used in post-treatment evaluation of gastric MALT lymphoma. Forty-five patients were analyzed. Within a median follow-up period of 34 months, 35 patients achieved both radiologic and endoscopic complete remission (CR). The median times to endoscopic and radiologic CR were not significantly different (21 versus 16 weeks, p = 0.118). However, in 25 patients with stage I disease, endoscopic CR [median (range), 20 (11-36)] was achieved later than radiologic CR [median (range), 13 (8-36)] (p = 0.027). Among 40 patients who achieved radiologic CR, 35 patients who also achieved endoscopic CR maintained remission during the follow-up. Two of the five patients who achieved radiologic CR without endoscopic CR experienced recurrence. In gastric DLBCL patients, endoscopic response does not always correlate with radiologic response and might predict disease recurrence. We suggest that follow-up endoscopic examination with biopsy should be performed in addition to radiologic examination.
Betz, C; Schleicher, P; Winkel, R; Hoffmann, R
2013-02-01
In this study we examined the tensile strength of core sutures of tendons. In particular, we examined the effect of having 2 or 4 stitch strands in the core suture as well as the effect of additional locking sutures on the tensile strength. 60 flexor tendons from the forepaws of freshly slaughtered swines were harvested for biomechanical testing. They were divided into 4 groups (A, B, C and D) of 15 sutures each. Group A: core suture after Zechner with 2 strands; group B: modified core suture with 4 strands; group C: modified core suture with 2 strands and 4 locking sutures; group D: modified core suture with 4 strands and 4 locking sutures. The primary tensile strength of the sutures was measured in Newton using the testing machine with a traction speed of 0.1 mm/s. Simultaneously, the increasing space forming at the suture was filmed against graph paper. Our command variables were force measured in Newton when forming a space of 2 mm as well as the force at which the suture failed. Statistical analysis was carried out with the software SPSS to produce a multivariate analysis with a statistical significance of p<0.05. Results are presented as averages including the 1st and 3rd quartile (1Q/3Q). Under traction to form a 2 mm space, the force measured with group A was 14.2 N (12.9/15.1 N). In group B the force 22.5 N (20.0/24.7 N) was significantly higher (p<0.05). Group C required a traction force of 28.7 N (23.5/35.8 N) which was significantly higher than for groups A and B. Group D required the significantly highest traction force of 42.0 N (39.5/46.0 N) to produce a 2 mm space. The force required for the suture to fail in group A was 19.9 N (17.9/22.8 N), in group B: 26.2 N (24.5/29.7 N), in group C 32.0 N (27.1/40.1 N) and in Group D 46.5 N (41.5/50.0 N); the differences between the gloups were all statistically significant. The primary tensile strength of core sutures after Zechner on flexor tendons from the forepaws of swines was significantly increased by doubling the number of sutures and also by use of 4 additional locking sutures. © Georg Thieme Verlag KG Stuttgart · New York.
Suture spanning augmentation of single-row rotator cuff repair: a biomechanical analysis.
Early, Nicholas A; Elias, John J; Lippitt, Steven B; Filipkowski, Danielle E; Pedowitz, Robert A; Ciccone, William J
2017-02-01
This in vitro study evaluated the biomechanical benefit of adding spanning sutures to single-row rotator cuff repair. Mechanical testing was performed to evaluate 9 pairs of cadaveric shoulders with complete rotator cuff repairs, with a single-row technique used on one side and the suture spanning technique on the other. The spanning technique included sutures from 2 lateral anchors securing tendon near the musculotendinous junction, spanning the same anchor placement from single-row repair. The supraspinatus muscle was loaded to 100 N at 0.25 Hz for 100 cycles, followed by a ramp to failure. Markers and a video tracking system measured anterior and posterior gap formation across the repair at 25-cycle intervals. The force at which the stiffness decreased by 50% and 75% was determined. Data were compared using paired t-tests. One single-row repair failed at <25 cycles. Both anterior and posterior gap distances tended to be 1 to 2 mm larger for the single-row repairs than for the suture spanning technique. The difference was statistically significant at all cycles for the posterior gap formation (P ≤ .02). The trends were not significant for the anterior gap (P ≥ .13). The loads at which the stiffness decreased by 50% and 75% did not differ significantly between the 2 types of repair (P ≥ .10). The suture spanning technique primarily improved posterior gap formation. Decreased posterior gap formation could reduce failure rates for rotator cuff repair. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
A Knowledge-Based System for the Computer Assisted Diagnosis of Endoscopic Images
NASA Astrophysics Data System (ADS)
Kage, Andreas; Münzenmayer, Christian; Wittenberg, Thomas
Due to the actual demographic development the use of Computer-Assisted Diagnosis (CAD) systems becomes a more important part of clinical workflows and clinical decision making. Because changes on the mucosa of the esophagus can indicate the first stage of cancerous developments, there is a large interest to detect and correctly diagnose any such lesion. We present a knowledge-based system which is able to support a physician with the interpretation and diagnosis of endoscopic images of the esophagus. Our system is designed to support the physician directly during the examination of the patient, thus prodving diagnostic assistence at the point of care (POC). Based on an interactively marked region in an endoscopic image of interest, the system provides a diagnostic suggestion, based on an annotated reference image database. Furthermore, using relevant feedback mechanisms, the results can be enhanced interactively.
Al Kadah, Basel; Piccoli, Micaela; Mullineris, Barbara; Colli, Giovanni; Janssen, Martin; Siemer, Stephan; Schick, Bernhard
2015-03-01
Endoscopic surgery for treatment of thyroid and parathyroid pathologies is increasingly gaining attention. The da Vinci system has already been widely used in different fields of medicine and quite recently in thyroid and parathyroid surgery. Herein, we report about modifications of the transaxillary approach in endoscopic surgery of thyroid and parathyroid gland pathologies using the da Vinci system. 16 patients suffering from struma nodosa in 14 cases and parathyroid adenomas in two cases were treated using the da Vinci system at the ENT Department of Homburg/Saar University and in cooperation with the Department of General Surgery in New Sant'Agostino Hospital, Modena/Italy. Two different retractors, endoscopic preparation of the access and three different incision modalities were used. The endoscopic preparation of the access allowed us to have a better view during preparation and reduced surgical time compared to the use of a headlamp. To introduce the da Vinci instruments at the end of the access preparation, the skin incisions were over the axilla with one incision in eight patients, two incisions in four patients and three incisions in a further four patients. The two and three skin incisions modality allowed introduction of the da Vinci instruments without arm conflicts. The use of a new retractor (Modena retractor) compared to a self-developed retractor made it easier during the endoscopic preparation of the access and the reposition of the retractor. The scar was hidden in the axilla and independent of the incisions selected, the cosmetic findings were judged by the patients to be excellent. The neurovascular structures such as inferior laryngeal nerve, superior laryngeal nerve and vessels, as well as the different pathologies, were clearly 3D visualized in all 16 cases. No paralysis of the vocal cord was observed. All patients had a benign pathology in their histological examination. The endoscopic surgery of the thyroid and parathyroid gland can be performed using the da Vinci system and offers an excellent, intra-operative, 3D visualization of the neurovascular structures. The new incision modalities, use of a new retractor, and endoscopic preparation of the access made the surgery easier and safer using the transaxillary access to the thyroid and parathyroid glands. The modified skin incisions allowed an improved movement of the da Vinci arms during operation.
Coons, David A; Barber, F Alan; Herbert, Morley A
2006-11-01
This study evaluated the strength and suture-tendon interface security of different suture configurations from triple-suture-loaded anchors. A juvenile bovine infraspinatus tendon was detached and repaired by use of 4 different suture combinations from 2 suture anchors: 3 simple sutures in each anchor (ThreeVo anchor; Linvatec, Largo, FL); 2 peripheral simple stitches and 1 central horizontal mattress suture passed deeper into the tendon, creating a larger footprint (bigfoot-print anchor); 2 peripheral simple stitches with 1 central horizontal mattress stitch passed through the same holes as the simple sutures (stitch-of-Burns); and 2 simple stitches (TwoVo anchor; Linvatec). The constructs were cyclically loaded between 10 N and 180 N for 3,500 cycles and then destructively tested. The number of cycles required to create a 5-mm gap and a 10-mm gap and the ultimate load to failure and failure mode were recorded. The ThreeVo anchor was strongest and most resistant to cyclic loading (P < .01). The TwoVo anchor was least resistant to cyclic loading. The stitch-of-Burns anchor was more resistant to cyclic loading than both the bigfoot-print anchor and the TwoVo anchor (P < .03). The ThreeVo, stitch-of-Burns, and TwoVo anchors were stronger than the bigfoot-print anchor (P < .05). Three simple sutures in an anchor hold better than two simple sutures. Three simple sutures provide superior suture-tendon security than combinations of one mattress and two simple stitches subjected to cyclic loading. A central mattress stitch placed more medially than two peripheral simple stitches (bigfoot-print anchor) configured to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as three simple stitches (ThreeVo anchor). Placing a central mattress stitch more medially than 2 peripheral simple stitches to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as 3 simple stitches.
The cervical cancer detection system based on an endoscopic rotary probe
NASA Astrophysics Data System (ADS)
Yang, Yanshuang; Hou, Qiang; Zhao, Huijuan; Qin, Zhuanping; Gao, Feng
2012-03-01
To acquire the optical diffuse tomographic image of the cervix, a novel endoscopic rotary probe is designed and the frequency domain measurement system is developed. The finite element method and Gauss-Newton method are proposed to reconstruct the image of the phantom. In the optical diffuse tomographic imaging of the cervix, an endoscopic probe is needed and the detection of light at different separation to the irradiation spot is necessary. To simplify the system, only two optical fibers are adopted for light irradiation and collection, respectively. Two small stepper motors are employed to control the rotation of the incident fiber and the detection fiber, respectively. For one position of source fiber, the position of the detection fiber is changed from -61.875° to -50.625° and 50.625° to 61.875° to the source fiber, respectively. Then, the position of the source fiber is changed to another preconcerted position, which deviates the precious source position in an angle of 11.25°, and the detection fiber rotates within the above angles. To acquire the efficient irradiation and collection of the light, a gradient-index (GRIN) lens is connected at the head of the optical fiber. The other end of the GRIN lens is cut to 45°. With this design, light from optical fiber is reflected to the cervix wall, which is perpendicular to the optical fiber or vice versa. Considering the cervical size, the external diameter of the endoscopic probe is made to 20mm. A frequency domain (FD) near-infrared diffuse system is developed aiming at the detection of early cervical cancer, which modulates the light intensity in radio frequency and measures the amplitude attenuation and the phase delay of the diffused light using heterodyne detection. Phantom experiment results demonstrate that the endoscopic rotary scan probe and the system perform well in the endoscopic measurement.
Shibazaki-Yorozuya, Reiko; Wang, Qian; Dechow, Paul C; Maki, Koutaro; Opperman, Lynne A
2012-06-01
Craniofacial sutures are bone growth fronts that respond and adapt to biomechanical environments. Little is known of the role sutures play in regulating the skull biomechanical environment during patency and fusion conditions, especially how delayed or premature suture fusion will impact skull biomechanics. Tgf-β3 has been shown to prevent or delay suture fusion over the short term in rat skulls, yet the long-term patency or its consequences in treated sutures is not known. It was therefore hypothesized that Tgf-β3 had a long-term impact to prevent suture fusion and thus alter the skull biomechanics. In this study, collagen gels containing 3 ng Tgf-β3 were surgically placed superficial to the posterior interfrontal suture (IFS) and deep to the periosteum in postnatal day 9 (P9) rats. At P9, P24, and P70, biting forces and strains over left parietal bone, posterior IFS, and sagittal suture were measured with masticatory muscles bilaterally stimulated, after which the rats were sacrificed and suture patency analyzed histologically. Results demonstrated that Tgf-β3 treated sutures showed less fusion over time than control groups, and strain patterns in the skulls of the Tgf-β3-treated group were different from that of the control group. Although bite force increased with age, no alterations in bite force were attributable to Tgf-β3 treatment. These findings suggest that the continued presence of patent sutures can affect strain patterns, perhaps when higher bite forces are present as in adult animals. Copyright © 2012 Wiley Periodicals, Inc.
Patel, Neha A; Carlin, Kristen; Bernstein, Joseph M
Current grading systems may not allow clinicians to reliably document and communicate adenotonsillar size in the clinical setting. A validated endoscopic grading system may be useful for reporting tonsillar size in future clinical outcome studies. This is especially important as tonsillar enlargement is the cause of a substantial health care burden on children. To propose and validate an easy-to-use flexible fiberoptic endoscopic grading system that provides physicians with a more accurate sense of the three-dimensional relationship of the tonsillar fossa to the upper-airway. 50 consecutive pediatric patients were prospectively recruited between February 2015 and February 2016 at a pediatric otolaryngology outpatient clinic. The patients had no major craniofacial abnormalities and were aged 1 to 16years. Each patient had data regarding BMI, Friedman palate position, OSA-18 survey results collected. For each child, digital video clips of fiberoptic nasopharyngeal, oropharyngeal and laryngeal exams were presented to 2 examiners. Examiners were asked to independently use the proposed Endoscopic tonsillar grading system, the Brodsky tonsillar grading scale, the Modified Brodsky tonsillar grading scale with a tongue depressor, and the Parikh adenoid grading system to rate adenotonsillar hypertrophy. Cohen's Kappa and weighted Kappa scores were used to assess interrater reliability for each of the four grading scales. The Spearman correlation was used to test the associations between each scale and OSA-18 scores, as well as Body Mass Index (BMI). 50 pediatric patients were included in this study (mean age 6.1years, range of 1year to 16years). The average BMI was 20. The average OSA-18 score was 61.7. The average Friedman palate position score was 1.34. Twelve percent of the patients had a Friedman palate position score≥3, which made traditional Brodsky grading of their tonsils impossible without a tongue depressor. All four scales showed strong agreement between the two raters. The weighted Kappa was 0.83 for the Modified Brodsky scale, 0.89 for the Brodsky scale, 0.94 for the Parikh scale to 0.98 for the Endoscopic scale (almost perfect agreement). The Endoscopic scale showed the most consistent agreement between the raters during the study. There was a moderate association between the Parikh adenoid grading system with OSA-18 scores (Spearman's ρ=0.58, p<0.001) compared to a low association of the tonsillar grading systems with OSA- 18 scores. None of the scales correlated with patient BMI. The proposed Endoscopic tonsillar grading system is as reliable of a method of grading tonsillar size as conventional grading systems. It offers the advantage of allowing for critical evaluation of the tonsils without any anatomic distortion which may occur with the use of a tongue blade. This new validated endoscopic grading system provides a tool for communicating the degree of airway obstruction at the level of the oropharynx regardless of Friedman palate position and may be used in future outcomes projects. Copyright © 2017 Elsevier Inc. All rights reserved.
Meisel, Adam F; Henninger, Heath B; Barber, F Alan; Getelman, Mark H
2017-05-01
The purpose of this study was to evaluate the time zero cyclic and failure loading properties of a linked single-row rotator cuff repair compared with a standard simple suture single-row repair using triple-loaded suture anchors. Eighteen human cadaveric shoulders from 9 matched pairs were dissected, and full-thickness supraspinatus tears were created. The tendon cross-sectional area was recorded. In each pair, one side was repaired with a linked single-row construct and the other with a simple suture single-row construct, both using 2 triple-loaded suture anchors. After preloading, specimens were cycled to 1 MPa of effective stress at 1 Hz for 500 cycles, and gap formation was recorded with a digital video system. Samples were then loaded to failure, and modes of failure were recorded. There was no statistical difference in peak gap formation between the control and linked constructs (3.6 ± 0.9 mm and 3.6 ± 1.2 mm, respectively; P = .697). Both constructs averaged below a 5-mm cyclic failure threshold. There was no statistical difference in ultimate load to failure between the control and linked repair (511.1 ± 139.0 N and 561.2 ± 131.8 N, respectively; P = .164), and both groups reached failure at loads similar to previous studies. Constructs failed predominantly via tissue tearing parallel to the medial suture line. The linked repair performed similarly to the simple single-row repair. Both constructs demonstrated high ultimate load to failure and good resistance to gap formation with cyclic loading, validating the time zero strength of both constructs in a human cadaveric model. The linked repair provided equivalent resistance to gap formation and failure loads compared with simple suture single-row repairs with triple-loaded suture anchors. This suggests that the linked repair is a simplified rip-stop configuration using the existing suture that may perform similarly to current rotator cuff repair techniques. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Park, Maxwell C; Peterson, Alexander; Patton, John; McGarry, Michelle H; Park, Chong J; Lee, Thay Q
2014-03-01
Rotator cuff repair involving fewer tendon suture passes without compromising biomechanical performance would represent a technical advancement. An inter-implant "medial pulley-mattress" transosseous-equivalent (MP-TOE) repair requiring fewer tendon suture-passes was hypothesized to provide equivalent biomechanical characteristics compared to the control. In 6 human cadaveric shoulders, a transosseous-equivalent (TOE) repair (control) was performed utilizing 2 separate medial mattresses resulting in 4 tendon-bridging sutures. In 6 matched-pairs, 2 single-loaded anchors were used to create a medial inter-implant mattress construct (all sutures shuttled in 1 tendon pass per anchor)-after knot-tying, the same tendon-bridging pattern as the control was created. A materials testing machine cyclically loaded each repair from 10-180 N for 30 cycles; each repair subsequently underwent failure testing. Gap and strain were measured with a video digitizing system. A "technical efficiency ratio" (TER) was defined as: (#knots + #suture passes + #suture limbs)/#fixation points. Cyclic and failure testing demonstrated no significant differences between constructs. Gap formation at cycle 30 was 5.3 ± 0.8 mm (TOE) and 5.0 ± 0.3 mm (MP-TOE) (P = .62). Cycle 30 anterior strain values were -16.0 ± 7.3% (TOE) and -15.8 ± 6.6% (MP-TOE) (P = .99). Yield loads were 208.7 ± 2.7 N (TOE) and 204.0 ± 1.3 N (MP-TOE) (P = .17). Mode of failure demonstrated less tendon cut-out with the MP-TOE repair. The MP-TOE repair has a TER of 2.0 vs 2.5 for the control. The MP-TOE repair requiring fewer tendon suture passes, yet creating an additional inter-implant mattress configuration, is biomechanically equivalent to the original TOE technique, and may limit failure with improved medial load-sharing capacity. A TER may help quantify technical ease and help standardize comparisons between repair techniques. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
Image-Based Navigation for Functional Endoscopic Sinus Surgery Using Structure From Motion.
Leonard, Simon; Reiter, Austin; Sinha, Ayushi; Ishii, Masaru; Taylor, Russel H; Hager, Gregory D
2016-01-01
Functional Endoscopic Sinus Surgery (FESS) is a challenging procedure for otolaryngologists and is the main surgical approach for treating chronic sinusitis, to remove nasal polyps and open up passageways. To reach the source of the problem and to ultimately remove it, the surgeons must often remove several layers of cartilage and tissues. Often, the cartilage occludes or is within a few millimeters of critical anatomical structures such as nerves, arteries and ducts. To make FESS safer, surgeons use navigation systems that register a patient to his/her CT scan and track the position of the tools inside the patient. Current navigation systems, however, suffer from tracking errors greater than 1 mm, which is large when compared to the scale of the sinus cavities, and errors of this magnitude prevent from accurately overlaying virtual structures on the endoscope images. In this paper, we present a method to facilitate this task by 1) registering endoscopic images to CT data and 2) overlaying areas of interests on endoscope images to improve the safety of the procedure. First, our system uses structure from motion (SfM) to generate a small cloud of 3D points from a short video sequence. Then, it uses iterative closest point (ICP) algorithm to register the points to a 3D mesh that represents a section of a patients sinuses. The scale of the point cloud is approximated by measuring the magnitude of the endoscope's motion during the sequence. We have recorded several video sequences from five patients and, given a reasonable initial registration estimate, our results demonstrate an average registration error of 1.21 mm when the endoscope is viewing erectile tissues and an average registration error of 0.91 mm when the endoscope is viewing non-erectile tissues. Our implementation SfM + ICP can execute in less than 7 seconds and can use as few as 15 frames (0.5 second of video). Future work will involve clinical validation of our results and strengthening the robustness to initial guesses and erectile tissues.
Image-based navigation for functional endoscopic sinus surgery using structure from motion
NASA Astrophysics Data System (ADS)
Leonard, Simon; Reiter, Austin; Sinha, Ayushi; Ishii, Masaru; Taylor, Russell H.; Hager, Gregory D.
2016-03-01
Functional Endoscopic Sinus Surgery (FESS) is a challenging procedure for otolaryngologists and is the main surgical approach for treating chronic sinusitis, to remove nasal polyps and open up passageways. To reach the source of the problem and to ultimately remove it, the surgeons must often remove several layers of cartilage and tissues. Often, the cartilage occludes or is within a few millimeters of critical anatomical structures such as nerves, arteries and ducts. To make FESS safer, surgeons use navigation systems that register a patient to his/her CT scan and track the position of the tools inside the patient. Current navigation systems, however, suffer from tracking errors greater than 1 mm, which is large when compared to the scale of the sinus cavities, and errors of this magnitude prevent from accurately overlaying virtual structures on the endoscope images. In this paper, we present a method to facilitate this task by 1) registering endoscopic images to CT data and 2) overlaying areas of interests on endoscope images to improve the safety of the procedure. First, our system uses structure from motion (SfM) to generate a small cloud of 3D points from a short video sequence. Then, it uses iterative closest point (ICP) algorithm to register the points to a 3D mesh that represents a section of a patients sinuses. The scale of the point cloud is approximated by measuring the magnitude of the endoscope's motion during the sequence. We have recorded several video sequences from five patients and, given a reasonable initial registration estimate, our results demonstrate an average registration error of 1.21 mm when the endoscope is viewing erectile tissues and an average registration error of 0.91 mm when the endoscope is viewing non-erectile tissues. Our implementation SfM + ICP can execute in less than 7 seconds and can use as few as 15 frames (0.5 second of video). Future work will involve clinical validation of our results and strengthening the robustness to initial guesses and erectile tissues.
NASA Astrophysics Data System (ADS)
Priester, Carolina; Dillaman, Richard M.; Gay, D. Mark
2005-12-01
The ecdysial suture is the region of the arthropod exoskeleton that splits to allow the animal to emerge during ecdysis. We examined the morphology and composition of the intermolt and premolt suture of the blue crab using light microscopy and scanning electron microscopy. The suture could not be identified by routine histological techniques; however 3 of 22 fluorescein isothiocyanate-labeled lectins tested (Lens culinaris agglutinin, Vicia faba agglutinin, and Pisum sativum agglutinin) differentiated the suture, binding more intensely to the suture exocuticle and less intensely to the suture endocuticle. Back-scattered electron (BSE) and secondary electron observations of fracture surfaces of intermolt cuticle showed less mineralized regions in the wedge-shaped suture as did BSE analysis of premolt and intermolt resin-embedded cuticle. The prism regions of the suture exocuticle were not calcified. X-ray microanalysis of both the endocuticle and exocuticle demonstrated that the suture was less calcified than the surrounding cuticle with significantly lower magnesium and phosphorus concentrations, potentially making its mineral more soluble. The presence or absence of a glycoprotein in the organic matrix, the extent and composition of the mineral deposited, and the thickness of the cuticle all likely contribute to the suture being removed by molting fluid, thereby ensuring successful ecdysis.
Bailleul, Alida M; Horner, John R
2016-08-01
Sutures and synchondroses, the fibrous and cartilaginous articulations found in the skulls of vertebrates, have been studied for many biological applications at the morphological scale. However, little is known about these articulations at the microscopic scale in non-mammalian vertebrates, including extant archosaurs (birds and crocodilians). The major goals of this paper were to: (i) document the microstructure of some sutures and synchondroses through ontogeny in archosaurs; (ii) compare these microstructures with previously published sutural histology (i.e. that of mammals); and (iii) document how these articulations with different morphological degrees of closure (open or obliterated) appear histologically. This was performed with histological analyses of skulls of emus, American alligators, a fossil crocodilian and ornithischian dinosaurs (hadrosaurids, pachycephalosaurids and ceratopsids). Emus and mammals possess a sutural periosteum until sutural fusion, but it disappears rapidly during ontogeny in American alligators. This study identified seven types of sutural mineralized tissues in extant and extinct archosaurs and grouped them into four categories: periosteal tissues; acellular tissues; fibrous tissues; and intratendinous tissues. Due to the presence of a periosteum in their sutures, emus and mammals possess periosteal tissues at their sutural borders. The mineralized sutural tissues of crocodilians and ornithischian dinosaurs are more variable and can also develop via a form of necrosis for acellular tissues and metaplasia for fibrous and intratendinous tissues. It was hypothesized that non-avian dinosaurs, like the American alligator, lacked a sutural periosteum and that their primary mode of ossification involved the direct mineralization of craniofacial sutures (instead of intramembranous ossification found in mammals and birds). However, we keep in mind that a bird-like sutural microstructure might have arisen within non-avian saurichians. While synchondroseal histology is relatively similar in archosaurs and mammals, the microstructural differences between the sutures of these two clades are undeniable. Moreover, the current results suggest that the degree of sutural closure can only accurately be known via microstructural analyses. This study sheds light on the microstructure and growth of archosaurian sutures and synchondroses, and reveals a unique, undocumented histological diversity in non-avian dinosaur skulls. © 2016 Anatomical Society.
Bisleri, Gianluigi; Giroletti, Laura; Hrapkowicz, Tomasz; Bertuletti, Martina; Zembala, Marian; Arieti, Mario; Muneretto, Claudio
2016-10-01
Despite the popularity of less invasive approaches for conduits procurement in coronary artery bypass graft surgery, concerns have been raised about the potential detrimental effects of the endoscopic technique when compared with the conventional "open" technique. Among 470 patients undergoing coronary surgery with the use of a radial artery conduit, a propensity score analysis was performed among those patients assigned either to an open technique (n = 82) or to an endoscopic approach (n = 82). Endoscopic harvesting was performed with a nonsealed system. The primary endpoint was cardiac-related mortality, and secondary endpoint was survival free from major cardiac and cerebrovascular adverse events. Moreover, hand and forearm sensory discomfort and forearm wound healing were also assessed. No conversion to the open technique occurred in patients undergoing endoscopic harvesting. No patients in either group showed hand ischemia; wound infection occurred only in the open group (open 7.3% versus endoscopic 0%, p = 0.007). Wound healing (Hollander scale) was considerably better in the endoscopic group (open 3.3, endoscopic 4.7; p < 0.001) as well as paresthesia at the latest follow-up (open 19.5% versus endoscopic 3.6%, p < 0.001). Pain (visual analog scale score) was significantly reduced with the endoscopic technique (open 3.2, endoscopic 1.2; p = 0.003). At 5 years of follow-up, freedom from cardiac-related mortality (open 96.3% ± 2.1% versus endoscopic 98.1% ± 1.8%; p = 0.448) as well as survival free from major cardiac and cerebrovascular adverse events (open 93.9% ± 2.6% versus endoscopic 93% ± 3.4%; p = 0.996) were similar among the groups. Endoscopic radial artery harvesting allows for incremental benefits in the short term in terms of improved cosmesis and reduced wound and neurologic complications, without yielding detrimental effects in terms of graft-related events at 5 years of follow-up. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Spectral-domain optical coherence tomography for endoscopic imaging
NASA Astrophysics Data System (ADS)
Chen, Xiaodong; Li, Qiao; Li, Wanhui; Wang, Yi; Yu, Daoyin
2007-02-01
Optical coherence tomography (OCT) is an emerging cross-sectional imaging technology. It uses broadband light sources to achieve axial image resolutions on the few micron scale. OCT is widely applied to medical imaging, it can get cross-sectional image of bio-tissue (transparent and turbid) with non-invasion and non-touch. In this paper, the principle of OCT is presented and the crucial parameters of the system are discussed in theory. With analysis of different methods and medical endoscopic system's feature, a design which combines the spectral domain OCT (SDOCT) technique and endoscopy is put forward. SDOCT provides direct access to the spectrum of the optical signal. It is shown to provide higher imaging speed when compared to time domain OCT. At the meantime, a novel OCT probe which uses advanced micromotor to drive reflecting prism is designed according to alimentary tract endoscopic feature. A simple optical coherence tomography system has been developed based on a fiber-based Michelson interferometer and spectrometer. An experiment which uses motor to drive prism to realize rotating imaging is done. Images obtained with this spectral interferometer are presented. The results verify the feasibility of endoscopic optical coherence tomography system with rotating scan.
Endoscopic near-infrared dental imaging with indocyanine green: a pilot study.
Li, Zhongqiang; Yao, Shaomian; Xu, Jian; Wu, Ye; Li, Chunhong; He, Ziying
2018-06-01
Current dental diagnosis, especially tooth abnormalities, relies largely on X-ray-based imaging, a technique that requires specialized skills and suffers from ionizing radiation. Here, we present a pilot study in rats of an efficient, ionizing-radiation-free and easy-to-use alternative for dental imaging. Postnatal rats at different ages were injected with indocyanine green and molars were imaged by a laboratory-designed endoscopic near-infrared (NIR) dental imaging system. The results indicate that the endoscopic NIR dental imaging can be used to observe the morphology of postnatal rat molars, especially at early postnatal stages when morphology of the molar is indistinguishable under visible conditions. A small abnormal cusp was observed and distinguished from the normal cusps by the NIR dental imaging system. Dental structures, such as unerupted molars, can be imaged as soon as 10 min after the injection of indocyanine green; imaging after 24 h shows improved imaging contrast. Overall, the endoscopic NIR fluorescence dental imaging system described here may be useful in dental research; this technique may serve as a safe, real-time imaging tool for dental diagnosis and treatment beyond experimental systems in the future. © 2018 New York Academy of Sciences.
Design and analysis of radial imaging capsule endoscope (RICE) system.
Ou-Yang, Mang; Jeng, Wei-De
2011-02-28
In this study, a radial imaging capsule endoscope (RICE) system is designed, which differs from a conventional front imaging capsule endoscope (FICE) system. To observe the wrinkled intima of the intestine, which spreads without folding around the circumference of the capsule when a capsule endoscope with a diameter that slightly exceeds that of the intestine passes through it, the RICE uses a cone mirror, a radial window shell, and a focus optical module that comprise the radial imaging system. This concept was demonstrated in a packaged optical simulator. The RICE optical model also has been established and verified by many simulations and experiments. In minimizing the sagittal and tangential aberrations, the optical module of the RICE has achieved an F-number of 4.2, a viewing angle of 65.08°, and an RMS radius of the 4th to 6th fields of less than 17 um. A comparison of these characteristics with those of the focus optical module that is used in FICE lenses reveals that the spot size is 50% larger for each field, and the modulation transfer function (MTF) is remarkably improved from 7% to 36% at 100 lp/mm on the 5th field of the sagittal plane.
Fang, Qi; Curatolo, Andrea; Wijesinghe, Philip; Yeow, Yen Ling; Hamzah, Juliana; Noble, Peter B.; Karnowski, Karol; Sampson, David D.; Ganss, Ruth; Kim, Jun Ki; Lee, Woei M.; Kennedy, Brendan F.
2017-01-01
In this paper, we describe a technique capable of visualizing mechanical properties at the cellular scale deep in living tissue, by incorporating a gradient-index (GRIN)-lens micro-endoscope into an ultrahigh-resolution optical coherence elastography system. The optical system, after the endoscope, has a lateral resolution of 1.6 µm and an axial resolution of 2.2 µm. Bessel beam illumination and Gaussian mode detection are used to provide an extended depth-of-field of 80 µm, which is a 4-fold improvement over a fully Gaussian beam case with the same lateral resolution. Using this system, we demonstrate quantitative elasticity imaging of a soft silicone phantom containing a stiff inclusion and a freshly excised malignant murine pancreatic tumor. We also demonstrate qualitative strain imaging below the tissue surface on in situ murine muscle. The approach we introduce here can provide high-quality extended-focus images through a micro-endoscope with potential to measure cellular-scale mechanics deep in tissue. We believe this tool is promising for studying biological processes and disease progression in vivo. PMID:29188108
Force sensor attachable to thin fiberscopes/endoscopes utilizing high elasticity fabric.
Watanabe, Tetsuyou; Iwai, Takanobu; Fujihira, Yoshinori; Wakako, Lina; Kagawa, Hiroyuki; Yoneyama, Takeshi
2014-03-12
An endoscope/fiberscope is a minimally invasive tool used for directly observing tissues in areas deep inside the human body where access is limited. However, this tool only yields visual information. If force feedback information were also available, endoscope/fiberscope operators would be able to detect indurated areas that are visually hard to recognize. Furthermore, obtaining such feedback information from tissues in areas where collecting visual information is a challenge would be highly useful. The major obstacle is that such force information is difficult to acquire. This paper presents a novel force sensing system that can be attached to a very thin fiberscope/endoscope. To ensure a small size, high resolution, easy sterilization, and low cost, the proposed force visualization-based system uses a highly elastic material-panty stocking fabric. The paper also presents the methodology for deriving the force value from the captured image. The system has a resolution of less than 0.01 N and sensitivity of greater than 600 pixels/N within the force range of 0-0.2 N.
NASA Astrophysics Data System (ADS)
Simhon, David; Gabay, Ilan; Shpolyansky, Gregory; Vasilyev, Tamar; Nur, Israel; Meidler, Roberto; Hatoum, Ossama Abu; Katzir, Abraham; Hashmonai, Moshe; Kopelman, Doron
2015-12-01
Laser tissue soldering is a method of repairing incisions. It involves the application of a biological solder to the approximated edges of the incision and heating it with a laser beam. A pilot clinical study was carried out on 10 patients who underwent laparoscopic cholecystectomy. Of the four abdominal incisions in each patient, two were sutured and two were laser soldered. Cicatrization, esthetical appearance, degree of pain, and pruritus in the incisions were examined on postoperative days 1, 7, and 30. The soldered wounds were watertight and healed well, with no discharge from these wounds or infection. The total closure time was equal in both methods, but the net soldering time was much shorter than suturing. There was no difference between the two types of wound closure with respect to the pain and pruritus on a follow-up of one month. Esthetically, the soldered incisions were estimated as good as the sutured ones. The present study confirmed that temperature-controlled laser soldering of human skin incisions is clinically feasible, and the results obtained were at least equivalent to those of standard suturing.
Simhon, David; Gabay, Ilan; Shpolyansky, Gregory; Vasilyev, Tamar; Nur, Israel; Meidler, Roberto; Hatoum, Ossama Abu; Katzir, Abraham; Hashmonai, Moshe; Kopelman, Doron
2015-01-01
Laser tissue soldering is a method of repairing incisions. It involves the application of a biological solder to the approximated edges of the incision and heating it with a laser beam. A pilot clinical study was carried out on 10 patients who underwent laparoscopic cholecystectomy. Of the four abdominal incisions in each patient, two were sutured and two were laser soldered. Cicatrization, esthetical appearance, degree of pain, and pruritus in the incisions were examined on postoperative days 1, 7, and 30. The soldered wounds were watertight and healed well, with no discharge from these wounds or infection. The total closure time was equal in both methods, but the net soldering time was much shorter than suturing. There was no difference between the two types of wound closure with respect to the pain and pruritus on a follow-up of one month. Esthetically, the soldered incisions were estimated as good as the sutured ones. The present study confirmed that temperature-controlled laser soldering of human skin incisions is clinically feasible, and the results obtained were at least equivalent to those of standard suturing.
Injectable suture device for intraocular lens fixation.
Smith, Jesse M; Erlanger, Michael; Olson, Jeffrey L
2015-12-01
We describe a surgical technique for scleral fixation of a posterior chamber intraocular lens (PC IOL) using a 24-gauge injectable polypropylene suture delivery system. A 3-piece PC IOL is inserted into the anterior chamber of the eye. Two sclerotomies are made 1.5 mm posterior to the limbus using a microvitreoretinal blade. The 24-gauge injector delivers a preformed suture loop into the eye with the double-armed needles still external to the eye. Each polypropylene IOL haptic is directed through the loop using microforceps. The suture loop is tightened around the haptic, and the attached needles are used to fixate the IOL to the sclera and close the sclerotomies simultaneously. This technique has been used in an ex vivo porcine eye and in an aphakic patient. In the latter, the IOL was quickly fixated to the sclera and maintained a stable position postoperatively. Dr. Olson has a patent pending for the device described in this article. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Tashiro, Hiraku; Oda, Susumu; Mori, Koji
2004-03-01
Because a worker complained of irritated eyes and throat due to glutaraldehyde (GA) in an endoscope syringe room, the automated endoscope washers and GA liquid stored in reserve were isolated in a separate room. A ventilation system was installed in this room, and the packing of the automated endoscope washers was changed. However, since the obnoxious smell of GA still remained in the endoscope syringe room, we had to determine the source of the smell. A plastic bucket with a cap was found to be filled with GA for disinfection of the endoscope apparatus. GA had evaporated when dispersed around the bucket, resulting in the obnoxious smell. The plastic bucket was replaced with a different type of container. Moreover, GA from the separate room did not affect the concentration of GA in the working area because the separate room for the automated endoscope washers had twice the ventilation volume proposed by the guidelines of the Society of Gastroenterology Nurses and Associates of the USA and the Healthcare Engineering Association of Japan. Consequently, we reconfirmed the significance of working environment improvement after clarifying the source of the harmful substance.
Terahertz endoscopic imaging for colorectal cancer detection: Current status and future perspectives
Doradla, Pallavi; Joseph, Cecil; Giles, Robert H
2017-01-01
Terahertz (THz) imaging is progressing as a robust platform for myriad applications in the field of security, health, and material science. The THz regime, which comprises wavelengths spanning from microns to millimeters, is non-ionizing and has very low photon energy: Making it inherently safe for biological imaging. Colorectal cancer is one of the most common causes of death in the world, while the conventional screening and standard of care yet relies exclusively on the physician’s experience. Researchers have been working on the development of a flexible THz endoscope, as a potential tool to aid in colorectal cancer screening. This involves building a single-channel THz endoscope, and profiling the THz response from colorectal tissue, and demonstrating endogenous contrast levels between normal and diseased tissue when imaging in reflection modality. The current level of contrast provided by the prototype THz endoscopic system represents a significant step towards clinical endoscopic application of THz technology for in-vivo colorectal cancer screening. The aim of this paper is to provide a short review of the recent advances in THz endoscopic technology and cancer imaging. In particular, the potential of single-channel THz endoscopic imaging for colonic cancer screening will be highlighted. PMID:28874955
Towards standardized assessment of endoscope optical performance: geometric distortion
NASA Astrophysics Data System (ADS)
Wang, Quanzeng; Desai, Viraj N.; Ngo, Ying Z.; Cheng, Wei-Chung; Pfefer, Joshua
2013-12-01
Technological advances in endoscopes, such as capsule, ultrathin and disposable devices, promise significant improvements in safety, clinical effectiveness and patient acceptance. Unfortunately, the industry lacks test methods for preclinical evaluation of key optical performance characteristics (OPCs) of endoscopic devices that are quantitative, objective and well-validated. As a result, it is difficult for researchers and developers to compare image quality and evaluate equivalence to, or improvement upon, prior technologies. While endoscope OPCs include resolution, field of view, and depth of field, among others, our focus in this paper is geometric image distortion. We reviewed specific test methods for distortion and then developed an objective, quantitative test method based on well-defined experimental and data processing steps to evaluate radial distortion in the full field of view of an endoscopic imaging system. Our measurements and analyses showed that a second-degree polynomial equation could well describe the radial distortion curve of a traditional endoscope. The distortion evaluation method was effective for correcting the image and can be used to explain other widely accepted evaluation methods such as picture height distortion. Development of consensus standards based on promising test methods for image quality assessment, such as the method studied here, will facilitate clinical implementation of innovative endoscopic devices.
Horizontal Running Mattress Suture Modified with Intermittent Simple Loops
Chacon, Anna H; Shiman, Michael I; Strozier, Narissa; Zaiac, Martin N
2013-01-01
Using the combination of a horizontal running mattress suture with intermittent loops achieves both good eversion with the horizontal running mattress plus the ease of removal of the simple loops. This combination technique also avoids the characteristic railroad track marks that result from prolonged non-absorbable suture retention. The unique feature of our technique is the incorporation of one simple running suture after every two runs of the horizontal running mattress suture. To demonstrate its utility, we used the suturing technique on several patients and analyzed the cosmetic outcome with post-operative photographs in comparison to other suturing techniques. In summary, the combination of running horizontal mattress suture with simple intermittent loops demonstrates functional and cosmetic benefits that can be readily taught, comprehended, and employed, leading to desirable aesthetic results and wound edge eversion. PMID:23723610
NASA Astrophysics Data System (ADS)
Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team
2011-03-01
Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.
Peer-assisted teaching of basic surgical skills.
Preece, Ryan; Dickinson, Emily Clare; Sherif, Mohamed; Ibrahim, Yousef; Ninan, Ann Susan; Aildasani, Laxmi; Ahmed, Sartaj; Smith, Philip
2015-01-01
Basic surgical skills training is rarely emphasised in undergraduate medical curricula. However, the provision of skills tutorials requires significant commitment from time-constrained surgical faculty. We aimed to determine how a peer-assisted suturing workshop could enhance surgical skills competency among medical students and enthuse them towards a career in surgery. Senior student tutors delivered two suturing workshops to second- and third- year medical students. Suturing performance was assessed before and after teaching in a 10-min suturing exercise (variables measured included number of sutures completed, suture tension, and inter-suture distance). Following the workshop, students completed a questionnaire assessing the effect of the workshop on their suturing technique and their intention to pursue a surgical career. Thirty-five students attended. Eighty-one percent believed their medical school course provided insufficient basic surgical skills training. The mean number of sutures completed post-teaching increased significantly (p < 0.001), and the standard deviation of mean inter-suture distance halved from ± 4.7 mm pre-teaching, to ± 2.6 mm post-teaching. All students found the teaching environment to be relaxed, and all felt the workshop helped to improve their suturing technique and confidence; 87% found the peer-taught workshop had increased their desire to undertake a career in surgery. Peer-assisted learning suturing workshops can enhance medical students' competence with surgical skills and inspire them towards a career in surgery. With very little staff faculty contribution, it is a cheap and sustainable way to ensure ongoing undergraduate surgical skills exposure.
Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I
2011-05-01
Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology. © 2011 The Authors. Journal of Anatomy © 2011 Anatomical Society of Great Britain and Ireland.
Han, Shuai; Cai, Zhai; Ning, Xuanjing; He, Linyun; Chen, Jun; Huang, Zonghai; Zhou, Huabin; Huang, Dequn; Zhang, Pusheng; Li, Zhou
2015-08-01
Various surgical small intestinal anastomosis methods are in current use, but improvements are always desired. Thus, we compared the feasibility, effectiveness, and safety of a new high-frequency electric welding (HFEW) system for sealing the small bowel versus a hand-sewn in vivo pig model. The 96 bowel segments of three pigs were randomized to be sutured either by the HFEW-300 PATONMED device (E.O. Paton Electric Welding Institute of the National Academy of Sciences of Ukraine, Kiev, Ukraine) or hand-sewn, and mucosa-to-mucosa fusions were subjected in vivo testing in the pigs. Bursting pressures, suture time, thermal damage, and the temperature of sealed ends were measured. Segments that had been treated with a hand-sutured ligature or double-sealed with HFEW were compared. Burst pressure was significantly higher in the hand-sutured group than in the HFEW group (136.2 mm Hg versus 75.8 mm Hg, P<.01). All 48 pig small bowels closed by the HFEW-300 generator showed a success rate of 100.0%. The closing time in the HFEW group was significantly shorter (P<.01). The pathological changes of the closed ends were mainly presented as acute thermal- and pressure-induced injuries. Outcomes of the current in vivo study suggest that HFEW is an effective and safe method for ligation of the small bowel in pigs.
Ultrasound biomicroscopy after canaloplasty: clinical study with two different units.
Doro, Daniele; Koerber, Norbert; Paolucci, Pierpaolo; Cimatti, Pierangela
2012-12-01
Canaloplasty is a recent non penetrating glaucoma surgical procedure where Schlemm's canal is dilated and trabecular meshwork distended by tensioning polypropylene suture. The aim of this study was to visualize the iridocorneal angle after the canaloplasty procedure by means of two different ultrasound biomicroscopy (UBM) units. Ten eyes of nine patients with primary open angle glaucoma (average age 62 years) underwent canaloplasty (six eyes) or canaloplasty combined with phacoemulsification and in-the-bag intraocular lens implantation (4 eyes). Both 50 MHz (Paradigm P45) and 80 MHz (i-UltraSound) systems were used. All procedures were performed by the same surgeon. UBM examination was performed 3 to 12 (mean 7 +/- 3.1) months after surgery. No, mild and good trabecular meshwork distension by suture tensioning was graded as 0, 1 and 2 according to the higher resolution 80 MHz images. Both ultrasound systems could show intrascleral lake and trabecular meshwork distension, which was graded as 0, 1 and 2 in 10%, 30% and 60% of eyes, respectively. Schlemm's canal could be imaged with the 80 MHz transducer only. The overall qualified success of canaloplasty (80%) was apparently correlated with suture tensioning (r=0.64). In our experience, after canaloplasty the 80 MHz but also 50 MHz technology can show trabecular meshwork distension. A greater number of eyes are needed to assess the correlation between intraocular pressure decrease and suture tensioning.
Schneider, Jochen; Harrasser, Norbert; Tübel, Jutta; Mühlhofer, Heinrich; Pförringer, Dominik; von Deimling, Constantin; Foehr, Peter; Kiefel, Barbara; Krämer, Christina; Stemberger, Axel; Schieker, Matthias
2018-01-01
Background Surgical sutures can promote migration of bacteria and thus start infections. Antiseptic coating of sutures may inhibit proliferation of adhered bacteria and avoid such complications. Objectives This study investigated the inhibition of viable adhering bacteria on novel antimicrobially coated surgical sutures using chlorhexidine or octenidine, a critical factor for proliferation at the onset of local infections. The medical need, a rapid eradication of bacteria in wounds, can be fulfilled by a high antimicrobial efficacy during the first days after wound closure. Methods As a pretesting on antibacterial efficacy against relevant bacterial pathogens a zone of inhibition assay was conducted with middle ranged concentrated suture coatings (22 μg/cm). For further investigation of adhering bacteria in detail the most clinically relevant Staphylococcus aureus (ATCC®49230™) was used. Absorbable braided sutures were coated with chlorhexidine-laurate, chlorhexidine-palmitate, octenidine-laurate, and octenidine-palmitate. Each coating type resulted in 11, 22, or 33 μg/cm drug content on sutures. Scanning electron microscopy (SEM) was performed once to inspect the coating quality and twice to investigate if bacteria have colonized on sutures. Adhesion experiments were assessed by exposing coated sutures to S. aureus suspensions for 3 h at 37°C. Subsequently, sutures were sonicated and the number of viable bacteria released from the suture surface was determined. Furthermore, the number of viable planktonic bacteria was measured in suspensions containing antimicrobial sutures. Commercially available sutures without drugs (Vicryl®, PGA Resorba®, and Gunze PGA), as well as triclosan-containing Vicryl® Plus were used as control groups. Results Zone of inhibition assay documented a multispecies efficacy of novel coated sutures against tested bacterial strains, comparable to most relevant S. aureus over 48 hours. SEM pictures demonstrated uniform layers on coated sutures with higher roughness for palmitate coatings and sustaining integrity of coated sutures. Adherent S. aureus were found via SEM on all types of investigated sutures. The novel antimicrobial sutures showed significantly less viable adhered S. aureus bacteria (up to 6.1 log) compared to Vicryl® Plus (0.5 log). Within 11 μg/cm drug-containing sutures, octenidine-palmitate (OL11) showed the highest number of viable adhered S. aureus (0.5 log), similar to Vicryl® Plus. Chlorhexidine-laurate (CL11) showed the lowest number of S. aureus on sutures (1.7 log), a 1.2 log greater reduction. In addition, planktonic S. aureus in suspensions were highly inhibited by CL11 (0.9 log) represents a 0.6 log greater reduction compared to Vicryl® Plus (0.3 log). Conclusions Novel antimicrobial sutures can potentially limit surgical site infections caused by multiple pathogenic bacterial species. Therefore, a potential inhibition of multispecies biofilm formation is assumed. In detail tested with S. aureus, the chlorhexidine-laurate coating (CL11) best meets the medical requirements for a fast bacterial eradication. This suture coating shows the lowest survival rate of adhering as well as planktonic bacteria, a high drug release during the first–clinically most relevant– 48 hours, as well as biocompatibility. Thus, CL11 coatings should be recommended for prophylactic antimicrobial sutures as an optimal surgical supplement to reduce wound infections. However, animal and clinical investigations are important to prove safety and efficacy for future applications. PMID:29315313
Obermeier, Andreas; Schneider, Jochen; Harrasser, Norbert; Tübel, Jutta; Mühlhofer, Heinrich; Pförringer, Dominik; Deimling, Constantin von; Foehr, Peter; Kiefel, Barbara; Krämer, Christina; Stemberger, Axel; Schieker, Matthias; Burgkart, Rainer; von Eisenhart-Rothe, Rüdiger
2018-01-01
Surgical sutures can promote migration of bacteria and thus start infections. Antiseptic coating of sutures may inhibit proliferation of adhered bacteria and avoid such complications. This study investigated the inhibition of viable adhering bacteria on novel antimicrobially coated surgical sutures using chlorhexidine or octenidine, a critical factor for proliferation at the onset of local infections. The medical need, a rapid eradication of bacteria in wounds, can be fulfilled by a high antimicrobial efficacy during the first days after wound closure. As a pretesting on antibacterial efficacy against relevant bacterial pathogens a zone of inhibition assay was conducted with middle ranged concentrated suture coatings (22 μg/cm). For further investigation of adhering bacteria in detail the most clinically relevant Staphylococcus aureus (ATCC®49230™) was used. Absorbable braided sutures were coated with chlorhexidine-laurate, chlorhexidine-palmitate, octenidine-laurate, and octenidine-palmitate. Each coating type resulted in 11, 22, or 33 μg/cm drug content on sutures. Scanning electron microscopy (SEM) was performed once to inspect the coating quality and twice to investigate if bacteria have colonized on sutures. Adhesion experiments were assessed by exposing coated sutures to S. aureus suspensions for 3 h at 37°C. Subsequently, sutures were sonicated and the number of viable bacteria released from the suture surface was determined. Furthermore, the number of viable planktonic bacteria was measured in suspensions containing antimicrobial sutures. Commercially available sutures without drugs (Vicryl®, PGA Resorba®, and Gunze PGA), as well as triclosan-containing Vicryl® Plus were used as control groups. Zone of inhibition assay documented a multispecies efficacy of novel coated sutures against tested bacterial strains, comparable to most relevant S. aureus over 48 hours. SEM pictures demonstrated uniform layers on coated sutures with higher roughness for palmitate coatings and sustaining integrity of coated sutures. Adherent S. aureus were found via SEM on all types of investigated sutures. The novel antimicrobial sutures showed significantly less viable adhered S. aureus bacteria (up to 6.1 log) compared to Vicryl® Plus (0.5 log). Within 11 μg/cm drug-containing sutures, octenidine-palmitate (OL11) showed the highest number of viable adhered S. aureus (0.5 log), similar to Vicryl® Plus. Chlorhexidine-laurate (CL11) showed the lowest number of S. aureus on sutures (1.7 log), a 1.2 log greater reduction. In addition, planktonic S. aureus in suspensions were highly inhibited by CL11 (0.9 log) represents a 0.6 log greater reduction compared to Vicryl® Plus (0.3 log). Novel antimicrobial sutures can potentially limit surgical site infections caused by multiple pathogenic bacterial species. Therefore, a potential inhibition of multispecies biofilm formation is assumed. In detail tested with S. aureus, the chlorhexidine-laurate coating (CL11) best meets the medical requirements for a fast bacterial eradication. This suture coating shows the lowest survival rate of adhering as well as planktonic bacteria, a high drug release during the first-clinically most relevant- 48 hours, as well as biocompatibility. Thus, CL11 coatings should be recommended for prophylactic antimicrobial sutures as an optimal surgical supplement to reduce wound infections. However, animal and clinical investigations are important to prove safety and efficacy for future applications.
[Application of inner figure-of-eight suture to laparoscopic colorectal surgery].
Chen, Jianjun; Zhong, Ming
2018-03-25
Regardless of laparoscopic or open colorectal surgeries, intestinal anastomosis is usually an important operative procedure. Even if stapler is widely used in different intestinal surgery nowadays, hand sewn suture is an indispensable procedure in clinical practice, meanwhile after stapled anastomosis, additional hand sewn suture is usually performed to ensure the safety of anastomosis. The inner figure-of-eight suture is a single layer suture technique which has been widely used in skin, tendon, rectus and uterus for quick and secure approximation. We describe our innovative application of inner figure-of-eight suture technique for intestinal anastomosis and/or reinforcement after stapled anastomosis in laparoscopic colorectal surgery. Main steps of inner figure-of-eight suture for intestinal anastomosis on posterior wall are as follows: (1) At 4 mm from cut edge of bowel, needle enters vertically from one side and courses mucosa-serosa-opposite serosa-mucosa in parallel to the entry point. (2) The needle is brought back to first entry side of bowel at 45 degree to enter the mucosa 5 mm below the first entry point and out on opposite side mucosa horizontally. (3) Both lose ends of the suture are pulled to approximate bowel edges and knots are tied on mucosal surface, in which suture line presents figure-of-eight on mucosal surface and two parallel suture lines are seen on serosal surface. When inner figure-of-eight suture is performed on anterior wall, the procedure is similar, but needle passes from serosa-mucosa-opposite mucosa-serosa and repeated to complete the inner figure-8 suture and knots are tied on serosa. The final look is two parallel sutures at 0.5 mm in between and the figure-of-eight remains inside the lumen. We did not deliberately try to invert the bowel edges, and if anastomosis is not satisfactory at final examination, simple interrupted seromuscular suture can be carried out. From 2015 till now, we have successfully completed inner figure-of-eight sutures in 38 cases receiving intestinal anastomosis reinforcement procedure and in 24 cases receiving hand sewn anastomosis. Comparison study revealed inner figure-of-eight suture presented shorter anastomotic time and less medical cost without anastomotic leakage, stump leakage or bleeding. No anastomotic stenosis was found at enteroscopy examination during follow up. We think that inner figure-of-eight suture possesses safe and simple advantages and is a manual suture technique worthy of promotion.
Khonsari, R H; Di Rocco, F; Arnaud, E; Sanchez, S; Tafforeau, P
2012-09-01
The developmental genetics and the biomechanics of sutures are well-studied topics, while their microanatomy is still imperfectly known. Here, we aim to investigate the structure of skull vault sutures using a high-resolution imaging device. We used synchrotron X-ray microtomography in order to obtain high-resolution images of skull vault sutures from an extant mammal (the mouse Mus musculus) and from an extinct fish (the placoderm Compagopiscis croucheri). We used segmentation and 3D reconstruction softwares in order to reveal the microanatomy of sutures in these species. The high-resolution images allowed us to study the distribution of osteocytes, the organisation of vascular canals, the shapes of the suture borders, the insertion of Sharpey's fibres, the bone growth lines and the structure of the soft tissues surrounding the sutures. Synchrotron imaging provides new perspectives for the study of the normal microanatomy of sutures. The submicronic resolution of the synchrotron scans gives access to the 3D organisation of structures that were previously only known in 2D, even in normal sutures. The description of anatomical entities such as vascular canals and Sharpey's fibres in abnormally fused sutures would be of interest in the understanding of craniosynostoses.
Blaker, J J; Nazhat, S N; Boccaccini, A R
2004-01-01
A novel silver-doped bioactive glass powder (AgBG) was used to coat resorbable Vicryl (polyglactin 910) and non-resorbable Mersilk surgical sutures, thereby imparting bioactive, antimicrobial and bactericidal properties to the sutures. Stable and homogeneous coatings on the surface of the sutures were achieved using an optimised aqueous slurry-dipping technique. Dynamic mechanical analysis (DMA) was used to investigate the viscoelastic parameters of storage modulus and tandelta and thermal transitions of the as-received and composite (coated) sutures. The results generally showed that the bioactive glass coating did not affect the dynamic mechanical and thermal properties of the sutures. The in vitro bioactivity of the sutures was tested by immersion in simulated body fluid (SBF). After only 3 days of immersion in SBF, bonelike hydroxyapatite formed on the coated suture surfaces, indicating their enhanced bioactive behaviour. Resorbable sutures with bioactive coatings as fabricated here, in conjunction with 3-D textile technology, may provide attractive materials for producing 3-D scaffolds with controlled porosities for tissue engineering applications. The bactericidal properties imparted by the Ag-containing glass coating open also new opportunities for use of the composite sutures in wound healing and body wall repair.
Karstensen, John Gásdal; Klausen, Pia Helene; Saftoiu, Adrian; Vilmann, Peter
2014-06-28
While flexible endoscopy is essential for macroscopic evaluation, confocal laser endomicroscopy (CLE) has recently emerged as an endoscopic method enabling visualization at a cellular level. Two systems are currently available, one based on miniprobes that can be inserted via a conventional endoscope or via a needle guided by endoscopic ultrasound. The second system has a confocal microscope integrated into the distal part of an endoscope. By adding molecular probes like fluorescein conjugated antibodies or fluorescent peptides to this procedure (either topically or systemically administered during on-going endoscopy), a novel world of molecular evaluation opens up. The method of molecular CLE could potentially be used for estimating the expression of important receptors in carcinomas, subsequently resulting in immediate individualization of treatment regimens, but also for improving the diagnostic accuracy of endoscopic procedures by identifying otherwise invisible mucosal lesions. Furthermore, studies have shown that fluorescein labelled drugs can be used to estimate the affinity of the drug to a target organ, which probably can be correlated to the efficacy of the drug. However, several of the studies in this research field have been conducted in animal facilities or in vitro, while only a limited number of trials have actually been carried out in vivo. Therefore, safety issues still needs further evaluations. This review will present an overview of the implications and pitfalls, as well as future challenges of molecular CLE in gastrointestinal diseases.
[Design of Adjustable Magnetic Field Generating Device in the Capsule Endoscope Tracking System].
Ruan, Chao; Guo, Xudong; Yang, Fei
2015-08-01
The capsule endoscope swallowed from the mouth into the digestive system can capture the images of important gastrointestinal tract regions. It can compensate for the blind spot of traditional endoscopic techniques. It enables inspection of the digestive system without discomfort or need for sedation. However, currently available clinical capsule endoscope has some limitations such as the diagnostic information being not able to correspond to the orientation in the body, since the doctor is unable to control the capsule motion and orientation. To solve the problem, it is significant to track the position and orientation of the capsule in the human body. This study presents an AC excitation wireless tracking method in the capsule endoscope, and the sensor embedded in the capsule can measure the magnetic field generated by excitation coil. And then the position and orientation of the capsule can be obtained by solving a magnetic field inverse problem. Since the magnetic field decays with distance dramatically, the dynamic range of the received signal spans three orders of magnitude, we designed an adjustable alternating magnetic field generating device. The device can adjust the strength of the alternating magnetic field automatically through the feedback signal from the sensor. The prototype experiment showed that the adjustable magnetic field generating device was feasible. It could realize the automatic adjustment of the magnetic field strength successfully, and improve the tracking accuracy.
[Mechanical suture in colorectal surgery].
Alecu, L; Pascu, A; Costan, I; Deacu, A; Marin, A; Corodeanu, G; Gulinescu, L
2001-01-01
Of this work was the study of using, as well as the utility of the mechanical sutures in colorectal surgery; because of the special caution needed to be taken for any colonic or rectal suture, more than any other digestive segment. The frequency of the postoperative fistulas after the suture and anastomosis is higher at this level and so it increases the period and costs of the hospitalization. We studied the possibilities of performing and evolution of 64 mechanical sutures for 19 patients, with colorectal pathology, hospitalized in our department from july 1999 to december 2000. We performed 64 mechanical sutures, as followed: 47 in open surgery and 17 in laparoscopic. From all these, 56 was bowel sutures, 8 of them were vascular (in laparoscopic, for cutting the most important vascular pedicles). We did 18 anastomosis: 15 in open and 3 in laparoscopic surgery. It was 2 postoperative fistulas from all 56 intestinal sutures (3.57%). We haven't any intra or postoperative bleeding from the vascular anastomosis. It was 3 intraoperative bleeding from the intestinal anastomosis, and only 1 case of postoperative bleeding (5.26% of the cases: 1.56% of all mechanical sutures). In only one case, the mechanical suture couldn't be initially done, but it succeeded after the removing of the segment of the bowel involved. Mechanical sutures offers a high level of safety to the colorectal anastomosis. It provides a very good vascularization to the anastomosis and decreases the time needed for performing the suture or anastomosis, versus manual sature. Also, for the patients with rectal ampular neoplasm, it creates the possibility of anal sphincter preservation by making a low colorectal anastomoses--which is difficult by manual suture.
Shear lag sutures: Improved suture repair through the use of adhesives
Linderman, Stephen W.; Kormpakis, Ioannis; Gelberman, Richard H.; Birman, Victor; Wegst, Ulrike G. K.; Genin, Guy M.; Thomopoulos, Stavros
2015-01-01
Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model. PMID:26022966
Reconstructive procedures for impaired upper airway function: laryngeal respiration
Müller, Andreas
2005-01-01
The larynx is the "bottleneck" of the human airway. For this reason, the effects of stenosing laryngeal pathologies on the vital factor respiratory gas exchange are particularly critical. Internal stabilization is a prerequisite for recovery of the laryngeal respiratory function in severe forms of inspiratory collapse (laryngomalacia). Effective laser surgery techniques have been developed to this end in recent years. Glottis-dilating surgery in cases of bilateral vocal cord motion impairment is now moving in the direction of endoscopic laser cordotomy or cordectomy, whereas arytenoidectomy and open surgical procedures are now used only rarely due to higher secondary morbidity rates. In individual cases, in particular if functional recovery is expected, temporary laterofixation of a vocal cord using an endoscopic suturing technique can be a helpful approach. Extensive laryngeal defects can be covered by means of composite grafts with mucosal lining, a supporting skeleton and their own vascularization. Autologous transplantation of the larynx, with its complex surgical and immunological problems, has become a manageable procedure. The problems of post-transplantation reinnervation and risk assessment of immunosuppression-induced recurrence of the tumor are still under consideration. Reanimation of the bilaterally paralyzed larynx by means of neurorrhaphy (neurosuture), neural grafting and, more recently, functional electrostimulation (pacemaker) represents a challenge for the coming years. In most cases of paralysis of the recurrent laryngeal nerve, a part of the muscles is maintained by synkinetic reinnervation when therapy is carried out, which however also prevents effective vocal cord movement due to simultaneous activity of agonists and antagonists. Modulation of reinnervation by means of electrostimulation and modern genetic therapy approaches justify hopes of better outcomes in the future. PMID:22073057
Kshettry, Varun R; Nyquist, Gurston; Evans, James J
2018-02-01
Surgery for craniopharyngiomas can be challenging due to the involvement of multiple critical neurovascular structures. The expanded endoscopic endonasal approach can provide superior access to suprasellar craniopharyngiomas, particularly with retrochiasmatic extension and significant hypothalamic involvement. We describe the surgical technique used to treat a 30-year-old patient who presented with 4 weeks of worsening vision, fatigue, and memory loss. His vision was counting fingers at 1 feet on the right and 20/800 on the left with a temporal hemianopsia. Laboratory evaluation demonstrated central hypoadrenalism, hypothyroidism, and hypogonadism. Imaging showed a large solid and cystic suprasellar mass. The transtubercular approach with removal of the lateral tubercular strut can provide wide bilateral access to the opticocarotid region. The superior intercavernous sinus must be coagulated and ligated. Initial arachnoid dissection is centered at the midline, mobilizing the superior hypophyseal branches to the optic apparatus laterally. The cyst capsule is opened and care is taken to minimize spillage of cyst fluid into the subarachnoid space. Central debulking and then extracapsular dissection is performed under direct visualization using sharp dissection. Reconstruction of the dura is performed with an inlay/onlay fascia lata button that is held together with four sutures that hold the graft edges against the native dural edges. This is followed by vascularized nasoseptal flap reconstruction. No lumbar drain or nonabsorbable packing is required. The patient's vision had dramatic improvement and by 1 week postoperatively was 20/20 with full visual fields. Postoperative diabetes insipidus was managed with nasal desmopressin. Postoperative MRI demonstrated complete removal. The link to the video can be found at: https://youtu.be/QQxCNUcq1qg .
Supervised autonomous robotic soft tissue surgery.
Shademan, Azad; Decker, Ryan S; Opfermann, Justin D; Leonard, Simon; Krieger, Axel; Kim, Peter C W
2016-05-04
The current paradigm of robot-assisted surgeries (RASs) depends entirely on an individual surgeon's manual capability. Autonomous robotic surgery-removing the surgeon's hands-promises enhanced efficacy, safety, and improved access to optimized surgical techniques. Surgeries involving soft tissue have not been performed autonomously because of technological limitations, including lack of vision systems that can distinguish and track the target tissues in dynamic surgical environments and lack of intelligent algorithms that can execute complex surgical tasks. We demonstrate in vivo supervised autonomous soft tissue surgery in an open surgical setting, enabled by a plenoptic three-dimensional and near-infrared fluorescent (NIRF) imaging system and an autonomous suturing algorithm. Inspired by the best human surgical practices, a computer program generates a plan to complete complex surgical tasks on deformable soft tissue, such as suturing and intestinal anastomosis. We compared metrics of anastomosis-including the consistency of suturing informed by the average suture spacing, the pressure at which the anastomosis leaked, the number of mistakes that required removing the needle from the tissue, completion time, and lumen reduction in intestinal anastomoses-between our supervised autonomous system, manual laparoscopic surgery, and clinically used RAS approaches. Despite dynamic scene changes and tissue movement during surgery, we demonstrate that the outcome of supervised autonomous procedures is superior to surgery performed by expert surgeons and RAS techniques in ex vivo porcine tissues and in living pigs. These results demonstrate the potential for autonomous robots to improve the efficacy, consistency, functional outcome, and accessibility of surgical techniques. Copyright © 2016, American Association for the Advancement of Science.
Spector, David; Rabi, Yaron; Vasserman, Irena; Hardy, Amos; Klausner, Joseph; Rabau, Micha; Katzir, Abraham
2009-09-01
In today's age of advancing surgical technology, there is a need for better and simpler methods of tissue bonding. The use of lasers for tissue welding or soldering is one of these sutureless methods. In 30 years of laser tissue bonding (LTB) research, published reports of cylindrical organ anastomosis were limited to small diameters. The tension resisted by the anastomosis, which is caused by the intraluminal pressure, is also proportional to the organ diameter. Therefore the anastomosis of large diameter organs requires significantly stronger mechanical strength. The aim of this study is to demonstrate such an anastomosis. In vitro anastomosis of porcine small bowel was performed by either LTB or sutures. Anastomosis in the laser group (number of samples, n = 15) included two main stages of soldering. The bowel edges were approximated over a solid albumin stent and heated with a temperature controlled GaAs laser system to 75 degrees C. This was followed by spreading liquid albumin on the anastomotic line and heating by the same system again to 75 degrees C. The control group (n = 5) was sutured anastomosis. All anastomoses were assessed by burst pressure measurement. The burst pressure of the laser group attained 170+/-40 mmHg which was significantly higher than that of the sutured group 83+/-37 mmHg (P < 0.001). This report describes the in vitro LTB anastomosis of a large diameter cylindrical organ. The immediate bond strength, as estimated by burst pressure measurements, was double compared to sutured anastomosis.
Cold Plasma Welding System for Surgical Skin Closure: In Vivo Porcine Feasibility Assessment.
Harats, Moti; Lam, Amnon; Maller, Michael; Kornhaber, Rachel; Haik, Josef
2016-09-29
Cold plasma skin welding is a novel technology that bonds skin edges through soldering without the use of synthetic materials or conventional wound approximation methods such as sutures, staples, or skin adhesives. The cold plasma welding system uses a biological solder applied to the edges of a skin incision, followed by the application of cold plasma energy. The objectives of this study were to assess the feasibility of a cold plasma welding system in approximating and fixating skin incisions compared with conventional methods and to evaluate and define optimal plasma welding parameters and histopathological tissue response in a porcine model. The cold plasma welding system (BioWeld1 System, IonMed Ltd, Yokneam, Israel) was used on porcine skin incisions using variable energy parameters. Wound healing was compared macroscopically and histologically to incisions approximated with sutures. When compared to sutured skin closure, cold plasma welding in specific system parameters demonstrated comparable and favorable wound healing results histopathologically as well as macroscopically. No evidence of epidermal damage, thermal or otherwise, was encountered in the specified parameters. Notably, bleeding, infection, and wound dehiscence were not detected at incision sites. Skin incisions welded at extreme energy parameters presented second-degree burns. Implementation of cold plasma welding has been shown to be feasible for skin closure. Initial in vivo results suggest cold plasma welding might provide equal, if not better, healing results than traditional methods of closure.
Moodley, Sean
2017-01-01
Background: The inverted T/keyhole pattern is commonly used for large breast reductions. This technique relies on the breast skin to retain the shape. With the passage of time “fallout” (pseudoptosis) occurs impairing the cosmetic result. A technique is described that uses parenchymal sutures and inframammary fold (IMF) reinforcement sutures to maintain the intraoperative shape. Methods: A retrospective study of 25 consecutive patients (50 breasts) where the IMF was reinforced and parenchymal sutures were inserted. The patients were followed up and the nipple to notch and nipple to IMF distance was measured and compared with that marked preoperatively and set intraoperatively. Complications, especially T junction breakdown, were also recorded. Results: The mean age was 38 years (range, 16–62 years) with a mean follow-up of 12 months. The mean body mass index was 31 (range, 22–41). The mean mass of tissue excised was 925 g (range, 340–1,800 g) per side. The distance from the suprasternal notch to the nipple remained unchanged. The distance from the nipple to the IMF remained the same as that marked preoperatively except in 3 patients who developed pseudoptosis. Only 3 patients had wound dehiscence. Conclusion: Parenchymal and superficial fascial system sutures combined with IMF reinforcement contributes to maintaining the aesthetic result and decreasing complications, in weight stable patients. PMID:29062642
Laparoscopic percutaneous jejunostomy with intracorporeal V-Loc jejunopexy in esophageal cancer.
Yang, Shun-Mao; Hsiao, Wei-Ling; Lin, Jui-Hsiang; Huang, Pei-Ming; Lee, Jang-Ming
2017-06-01
Barbed sutures are widely used in various laparoscopic digestive surgeries. The purpose of this paper is to present our initial experience of laparoscopic percutaneous jejunostomy with unidirectional barbed sutures in esophageal cancer patients and compare it with our early cases using traditional transabdominal sutures. A total of 118 esophageal cancer patients who underwent laparoscopic percutaneous jejunostomy were identified in a single institution in Taiwan from June 2014 to May 2016. The authors' traditional technique consisted of using transabdominal sutures with bolsters to fix a jejunum loop onto the anterior abdominal wall. A novel technique was introduced using intracorporeal suturing with knotless unidirectional barbed monofilament absorbable sutures (V-Loc) to attain a seal around the feeding catheter. A comparison between these two techniques was performed. Twenty cases with barbed V-Loc sutures and 98 cases with transabdominal sutures were identified. The V-Loc sutures appeared to reduce peristomal skin ulcers (19.4 vs. 0 %, p = 0.040), postoperative pain scores during the first 24 h (1.8 ± 1.4 vs. 0.9 ± 1.1, p = 0.007) and on postoperative day 2 (1.7 ± 1.4 vs. 1.0 ± 0.8, p = 0.026) when compared to patients receiving transabdominal sutures. The mean suturing time using V-Loc sutures was 22 min (14-60 min). The mean onset to resumption of enteral feeding was 1.8 ± 0.8 days and the mean duration of postoperative hospital stay was 8 ± 5.1 days, both of which were comparable in the two groups. There was no surgical mortality in our series. In the study cohort, the use of knotless unidirectional barbed sutures instead of traditional transabdominal sutures had similar outcomes and appears to be a feasible option for intracorporeal jejunopexy when performing laparoscopic jejunostomy in patients with esophageal cancer.
Lambertz, Andreas; Schröder, Kai Michael; Schöb, Dominik Stefan; Binnebösel, Marcel; Anurov, Michael; Klinge, Uwe; Neumann, Ulf Peter; Klink, Christian Daniel
2015-01-01
Biocompatibility and tissue integration of a surgical suture are decisive factors for wound healing and therefore for the success of sutures. The optimal suture material is still under discussion. Polyvinylidene fluoride (PVDF) is described to have superior properties of biocompatibility and is therefore frequently used as a mesh component. Only little information is available about its use as a suture material. The aim of this study was to evaluate the biocompatibility of PVDF as a suture material in comparison to 5 different established sutures in a rat model. In 30 male rats, a monofilamental PVDF suture (Resopren®) and 5 established control suture materials [polyester (Miralene®), polytetrafluoroethylene (Gore®), poliglecaprone (Monocryl®), polydioxanone (Monoplus®), polyglactin 910 (Vicryl®), USP size 3-0] were placed in the subcutaneous layer of the abdominal wall without knot or tension. After 3, 7 or 21 days, the abdominal walls were explanted for histopathological and immunohistochemical investigation with special regard to the size and quality of foreign body granuloma and the length of the comet tail-like infiltrate (CTI). The PVDF sutures showed the smallest size of foreign body granuloma (60 ± 14 µm) and the smallest CTI length (343 ± 60 µm) of all polymers after 21 days. Only PVDF (Resopren) and polydioxanone (Monoplus) showed a significant collagen I/III ratio increase between days 3 and 21 (p = 0.009 and p = 0.016). The quality of foreign body reaction regarding inflammation, proliferation and fibrotic remodeling was similar between all suture materials. Our data indicate that monofilamental PVDF sutures show a favorable foreign body reaction with small granuloma sizes and CTI length in comparison to established sutures. Its use as a suture material in general surgery could therefore be extended in the future. To reinforce these findings, further clinical studies need to be conducted. 2015 S. Karger AG, Basel.
Okamoto, Takumi; Koide, Tetsushi; Sugi, Koki; Shimizu, Tatsuya; Anh-Tuan Hoang; Tamaki, Toru; Raytchev, Bisser; Kaneda, Kazufumi; Kominami, Yoko; Yoshida, Shigeto; Mieno, Hiroshi; Tanaka, Shinji
2015-08-01
With the increase of colorectal cancer patients in recent years, the needs of quantitative evaluation of colorectal cancer are increased, and the computer-aided diagnosis (CAD) system which supports doctor's diagnosis is essential. In this paper, a hardware design of type identification module in CAD system for colorectal endoscopic images with narrow band imaging (NBI) magnification is proposed for real-time processing of full high definition image (1920 × 1080 pixel). A pyramid style image segmentation with SVMs for multi-size scan windows, which can be implemented on an FPGA with small circuit area and achieve high accuracy, is proposed for actual complex colorectal endoscopic images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Ricardo W.; Brown, Richard S.; Deters, Katherine A.
Ultraviolet radiation (UVR) can be used as a tool to disinfect surgery tools used for implanting transmitters into fish. However, the use of UVR could possibly degrade monofilament suture material used to close surgical incisions. This research examined the effect of UVR on monofilament sutures to determine if they were compromised and negatively influenced tag and suture retention, incision openness, or tissue reaction. Eighty juvenile Chinook salmon Oncorhynchus tshawytscha were surgically implanted with an acoustic transmitter and a passive integrated transponder. The incision was closed with a single stitch of either a suture exposed to 20 doses of UV radiationmore » (5 minute duration per dose) or a new, sterile suture. Fish were then held for 28 d and examined under a microscope at day 7, 14, 21 and 28 for incision openness, ulceration, redness, and the presence of water mold. There was no significant difference between treatments for incision openness, redness, ulceration or the presence of water mold on any examination day. On day 28 post-surgery, there were no lost sutures; however, 2 fish lost their transmitters (one from each treatment). The results of this study do not show any differences in negative influences such as tissue response, suture retention or tag retention between a new sterile suture and a suture disinfected with UVR.« less
Huh, Beom Kang; Kim, Byung Hwi; Kim, Se-Na; Park, Chun Gwon; Lee, Seung Ho; Kim, Ka Ryeong; Heo, Chan Yeong; Choy, Young Bin
2017-10-01
In this work, we propose a surgical suture that can sustainably release diclofenac (DF) for the local pain relief of surgical wounds. We separately fabricated a DF-loaded strand composed of a biodegradable polymer, poly(lactic-co-glycolic acid) (PLGA), which was then braided with a surgical suture already in clinical use, i.e., VICRYL™. In this way, the drug-delivery suture presented herein could release DF in a sustained manner for 10days while maintaining the mechanical strength needed for wound closure. According to the in vivo results of an induced-pain animal model, the drug-delivery suture mitigated pain throughout the period of persistent pain. The histological analysis of tissue around the sutures showed that the drug-delivery suture exhibited biocompatibility comparable to that of the VICRYL™ suture in clinical use. Copyright © 2017 Elsevier B.V. All rights reserved.
Mudgil, A V; To, K W; Balachandran, R M; Janigian, R H; Tsiaras, W G
1999-01-01
To determine the optimal wavelength for subconjunctival laser suture lysis. 130 black monofilament 10-0 nylon sutures were sewn subconjunctivally into the bare sclera of enucleated rabbit globes. The lowest energy levels facilitating laser suture lysis were determined for the argon green (514.5 NM), argon blue-green (488.0 NM, 514.5 NM), and krypton red (647.1 NM) wavelengths. In addition, absorption spectroscopy was performed on the suture material and conjunctiva using the Perkin Elmer W/VIS Lambda 2 spectrometer. Krypton red produced the fewest buttonhole defects, and it was also the most efficient energy source for suture lysis (P = 0.0001) under nontenectomized conjunctiva. Absorbance spectra studies revealed peak absorbance at 628 NM for the 10-0 nylon suture material. Based on animal and absorption spectroscopy studies, krypton red may be a safer and more efficient wavelength for subconjunctival laser suture lysis.
Endoscopic Management of Peri-Pancreatic Fluid Collections.
Yip, Hon Chi; Teoh, Anthony Yuen Bun
2017-09-15
In the past decade, there has been a progressive paradigm shift in the management of peri-pancreatic fluid collections after acute pancreatitis. Refinements in the definitions of fluid collections from the updated Atlanta classification have enabled better communication amongst physicians in an effort to formulate optimal treatments. Endoscopic ultrasound (EUS)-guided drainage of pancreatic pseudocysts has emerged as the procedure of choice over surgical cystogastrostomy. The approach provides similar success rates with low complications and better quality of life compared with surgery. However, an endoscopic "step up" approach in the management of pancreatic walled-off necrosis has also been advocated. Both endoscopic and percutaneous drainage routes may be used depending on the anatomical location of the collections. New-generation large diameter EUS-specific stent systems have also recently been described. The device allows precise and effective drainage of the collections and permits endoscopic necrosectomy through the stents.
Kumar, Nitin
2015-01-01
A new paradigm in the treatment of obesity and metabolic disease is developing. The global obesity epidemic continues to expand despite the availability of diet and lifestyle counseling, pharmacologic therapy, and weight loss surgery. Endoscopic procedures have the potential to bridge the gap between medical therapy and surgery. Current primary endoscopic bariatric therapies can be classified as restrictive, bypass, space-occupying, or aspiration therapy. Restrictive procedures include the USGI Primary Obesity Surgery Endolumenal procedure, endoscopic sleeve gastroplasty using Apollo OverStitch, TransOral GAstroplasty, gastric volume reduction using the ACE stapler, and insertion of the TERIS restrictive device. Intestinal bypass has been reported using the EndoBarrier duodenal-jejunal bypass liner. A number of space-occupying devices have been studied or are in use, including intragastric balloons (Orbera, Reshape Duo, Heliosphere BAG, Obalon), Transpyloric Shuttle, and SatiSphere. The AspireAssist aspiration system has demonstrated efficacy. Finally, endoscopic revision of gastric bypass to address weight regain has been studied using Apollo OverStitch, the USGI Incisionless Operating Platform Revision Obesity Surgery Endolumenal procedure, Stomaphyx, and endoscopic sclerotherapy. Endoscopic therapies for weight loss are potentially reversible, repeatable, less invasive, and lower cost than various medical and surgical alternatives. Given the variety of devices under development, in clinical trials, and currently in use, patients will have multiple endoscopic options with greater efficacy than medical therapy, and with lower invasiveness and greater accessibility than surgery. PMID:26240686
Kumar, Nitin
2015-07-25
A new paradigm in the treatment of obesity and metabolic disease is developing. The global obesity epidemic continues to expand despite the availability of diet and lifestyle counseling, pharmacologic therapy, and weight loss surgery. Endoscopic procedures have the potential to bridge the gap between medical therapy and surgery. Current primary endoscopic bariatric therapies can be classified as restrictive, bypass, space-occupying, or aspiration therapy. Restrictive procedures include the USGI Primary Obesity Surgery Endolumenal procedure, endoscopic sleeve gastroplasty using Apollo OverStitch, TransOral GAstroplasty, gastric volume reduction using the ACE stapler, and insertion of the TERIS restrictive device. Intestinal bypass has been reported using the EndoBarrier duodenal-jejunal bypass liner. A number of space-occupying devices have been studied or are in use, including intragastric balloons (Orbera, Reshape Duo, Heliosphere BAG, Obalon), Transpyloric Shuttle, and SatiSphere. The AspireAssist aspiration system has demonstrated efficacy. Finally, endoscopic revision of gastric bypass to address weight regain has been studied using Apollo OverStitch, the USGI Incisionless Operating Platform Revision Obesity Surgery Endolumenal procedure, Stomaphyx, and endoscopic sclerotherapy. Endoscopic therapies for weight loss are potentially reversible, repeatable, less invasive, and lower cost than various medical and surgical alternatives. Given the variety of devices under development, in clinical trials, and currently in use, patients will have multiple endoscopic options with greater efficacy than medical therapy, and with lower invasiveness and greater accessibility than surgery.
Primary Central Nervous System Lymphoma of Optic Chiasma: Endoscopic Endonasal Treatment.
Ozdemir, Evin Singar; Yildirim, Ali Erdem; Can, Aslihan Yavas
2018-01-01
Isolated primary central nervous system lymphoma arising from anterior visual pathway is very rare. A 76-year-old immunocompetent previously healthy man presented bilateral decreased visual acuity in 1 month. Pituitary magnetic resonans imaging (MRI) showed a lobulated mass with homogeneous enhancement after gadolinium administration that arising from optic chiasm suggested that inflammatory disease or an optic glioma. The patient underwent an extended endoscopic endonasal transsphenoidal surgery. Postoperative course and outcomes were wonderful. Histopathological diagnosis was diffuse large B-cell lymphoma. The patient underwent investigations for systemic lymphomatous involvement, did not detect any evidence of systemic disease. In this case, we claimed that differential diagnoses of anterior visual pathway lesions are difficult because of similarity of lesions on clinical and radiological examinations. Biopsy is essential for these lesions. As a biopsy technique, endoscopic endonasal transsphenoidal approach is safer and more effective than open procedures.
Characterization of craniofacial sutures using the finite element method.
Maloul, Asmaa; Fialkov, Jeffrey; Wagner, Diane; Whyne, Cari M
2014-01-03
Characterizing the biomechanical behavior of sutures in the human craniofacial skeleton (CFS) is essential to understand the global impact of these articulations on load transmission, but is challenging due to the complexity of their interdigitated morphology, the multidirectional loading they are exposed to and the lack of well-defined suture material properties. This study aimed to quantify the impact of morphological features, direction of loading and suture material properties on the mechanical behavior of sutures and surrounding bone in the CFS. Thirty-six idealized finite element (FE) models were developed. One additional specimen-specific FE model was developed based on the morphology obtained from a µCT scan to represent the morphological complexity inherent in CFS sutures. Outcome variables of strain energy (SE) and von Mises stress (σvm) were evaluated to characterize the sutures' biomechanical behavior. Loading direction was found to impact the relationship between SE and interdigitation index and yielded varied patterns of σvm in both the suture and surrounding bone. Adding bone connectivity reduced suture strain energy and altered the σvm distribution. Incorporating transversely isotropic material properties was found to reduce SE, but had little impact on stress patterns. High-resolution µCT scanning of the suture revealed a complex morphology with areas of high and low interdigitations. The specimen specific suture model results were reflective of SE absorption and σvm distribution patterns consistent with the simplified FE results. Suture mechanical behavior is impacted by morphologic factors (interdigitation and connectivity), which may be optimized for regional loading within the CFS. © 2013 Elsevier Ltd. All rights reserved.
In Vitro Tensile Strength Study on Suturing Technique and Material.
González-Barnadas, Albert; Camps-Font, Octavi; Espanya-Grifoll, Dunia; España-Tost, Antoni; Figueiredo, Rui; Valmaseda-Castellón, Eduard
2017-06-01
Suture technique and materials are important in preventing complications such as wound dehiscences. The purpose of this study was to determine the tensile strength of different suturing techniques, comparing several materials with different diameters. One hundred sixty sutures were performed using silk, e-PTFE, and 2 types of polyamide (monofilament and Supramid). Ten simple, 10 horizontal mattress, and 10 combinations of the two stitches were performed with 4-0 gauge of each material. Additionally, 10 simple sutures were performed with the 5-0 gauge of each material. The maximum tensile force resisted by each suture was recorded. When 5 mm of traction was applied, the polyamide monofilament resisted significantly better without untying or breaking compared with Supramid or silk, while the e-PTFE was superior to all the others. However, the force when e-PTFE 4-0 sutures untied or broke was lower than for either type of polyamide. The combined technique withstood a significantly higher tensile force before unknotting or breaking than did the simple and mattress stitches. The 5-0 gauges of silk and both types of polyamide showed lower tensile strengths than the 4-0 materials. Among the 5-0 sutures, Supramid showed a higher tensile strength than silk. The combined suture technique possessed greater tensile strength than did a simple or a horizontal mattress suture, and e-PTFE 4-0 withstood more traction without untying or breaking than did all the other materials, although at a lower tensile force. With the exception of e-PTFE, 4-0 sutures had greater tensile strength than did 5-0 sutures.
Shah, Hemendra N; Nayyar, Rishi; Rajamahanty, Shrinivas; Hemal, Ashok K
2012-06-01
To evaluate the usage of unidirectional barbed suture and its related implications in various surgeon-controlled robotic reconstructive urologic surgeries. From March 2010 to March 2011, all patients undergoing various surgeon-controlled robotic reconstructive urologic surgeries utilizing barbed sutures were prospectively enrolled in this study. Type and number of procedure performed were noted. Intraoperative and peri-operative outcomes potentially related to suture technique and material were recorded. This study reports on 210 patients, in whom barbed suture was used during this period. These included partial nephrectomy (20), pyeloplasty (9), ureteric tailoring and reimplantation (1), closure of bladder after Nephroureterectomy with excision of bladder cuff (8), closure of vaginal cuff in female radical cystectomy (12), partial cystectomy (1), radical prostatectomy (152), simple prostatectomy (2), vesicovaginal fistula repair (3), sacrocolpopexy (1), and hernia repair (1). We encountered 5 instances (2.38%) of tissue cut through possibly attributable to the use of barbed suture and 4 instances of misplacement of suture occurred, of these two required a new suture, whereas retrograde pull back of suture and needle was performed in 2 cases. No instance of slip back/loosening of suture was noted once it was tightened. At mean follow-up of 6.8 (1-14 months) months, we did not encounter any complications of urinary leakage, stone formation or fistula or any clinical evidence of urinary tract obstruction due to the use of barbed suture. Use of unidirectional barbed suture is safe, feasible, and efficient at short-term follow-up for reconstructive part of urological procedures.
Biocompatibility and strength properties of nitinol shape memory alloy suture in rabbit tendon.
Kujala, Sauli; Pajala, Ari; Kallioinen, Matti; Pramila, Antti; Tuukkanen, Juha; Ryhänen, Jorma
2004-01-01
Nitinol (NiTi) is a promising new tendon suture material with good strength, easy handling and good super-elastic properties. NiTi sutures were implanted for biocompatibility testing into the right medial gastrocnemius tendon in 15 rabbits for 2, 6 and 12 weeks. Additional sutures were implanted in subcutaneous tissue for strength measurements in order to determine the effect of implantation on strength properties of NiTi suture material. Braided polyester sutures (Ethibond) of approximately the same diameter were used as control. Encapsulating membrane formation around the sutures was minimal in the case of both materials. The breaking load of NiTi was significantly greater compared to braided polyester. Implantation did not affect the strength properties of either material.
Perioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery
Cho, Yang Kyeung
2009-01-01
Purpose To evaluate the factors that affect postoperative astigmatism and post-suture removal astigmatism, and to evaluate the risk factors associated with astigmatism axis shift. Methods We performed a retrospective chart review of 130 eyes that had undergone uneventful phacoemulsification cataract surgery. Preoperative astigmatism was divided into four groups (Groups I, II, III, and IV) according to the differences between the axis of preoperative astigmatism (flattest axis) and the incision axis (105 degrees). We analyzed the magnitude and axis of the induced astigmatism after the operation and after suture removal in each group. We also analyzed the factors which affected the postoperative astigmatism and post-suture removal astigmatism in each sub-group of Groups I, II, III, and IV, excluding postoperative or post-suture removal axis shift (specifically, Group IWAS, IIWAS, IIIWAS, and IVWAS). We identified the variables associated with the prevalence of postoperative astigmatism axis shift and those associated with the prevalence of post-suture removal axis shift. Results An increase in the magnitude of postoperative astigmatism was associated with an increase in the preoperative magnitude of astigmatism in Groups IWAS, IIWAS, and IIIWAS (p<0.05), and with an increase in the corneal tunnel length in Group IWAS. A decrease in the magnitude of postoperative astigmatism was associated with an increase in the corneal tunnel length in Groups IIIWAS and IVWAS (p<0.05). An increase in the magnitude of post-suture removal astigmatism was associated with an increase in the magnitude of postoperative astigmatism in Groups IWAS and IVWAS (p<0.05), and with late suture removal in Group IVWAS (p<0.05). A decrease in the magnitude of post-suture removal astigmatism was associated with late suture removal in Groups IWAS and IIWAS. A logistic regression analysis showed that the prevalence of post-suture removal astigmatism axis shift was associated with increased corneal tunnel length, decreased magnitude of postoperative astigmatism, and early suture removal. Conclusions In order to reduce postoperative and post-suture removal astigmatism, we recommend a short corneal tunnel length and late suture removal in patients with Group IWAS characteristics, late suture removal in Group IIWAS-like patients, long corneal tunnel length in Group IIIWAS-like patients, and long corneal tunnel length and early suture removal in patients with characteristics of Group IVWAS. PMID:20046682
T-tube drainage of the common bile duct choleperitoneum: etiology and management.
Daldoul, S; Moussi, A; Zaouche, A
2012-06-01
External drainage of the common bile duct by placement of a T-tube is a common practice after choledochotomy. This practice may result in the specific complication of bile peritonitis due to leakage after removal of the T-tube. This complication has multiple causes: some are patient-related (corticotherapy, chemotherapy, ascites), and others are due to technical factors (inappropriate suturing of the drain to the ductal wall, minimal inflammatory reaction related to some drain materials). The clinical presentation is quite variable depending on the amount and rapidity of intra-peritoneal spread of of bile leakage. Abdominal ultrasound (US), with US-guided needle aspiration and occasionally Technetium(99) scintigraphy are useful for diagnosis. Traditional therapy consists of surgical intervention including peritoneal lavage and re-intubation of the choledochal fistulous tract to allow for a further period of external drainage. When leakage is walled off and well-tolerated, a more nuanced and less invasive conservative therapy may combine percutaneous drainage with endoscopic placement of a trans-ampullary biliary drainage. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Laparoscopic jejunostomy for obstructing upper gastrointestinal malignancies
TSUJIMOTO, HIRONORI; HIRAKI, SHUICHI; TAKAHATA, RISA; NOMURA, SHINSUKE; ITO, NOZOMI; KANEMATSU, KYOHEI; HORIGUCHI, HIROYUKI; AOSASA, SUEFUMI; YAMAMOTO, JUNJI; HASE, KAZUO
2015-01-01
The aim of this study was to describe a minimally invasive laparoscopic jejunostomy (Lap-J) technique for obstruction due to upper gastrointestinal malignancies and evaluate the nutritional benefit of Lap-J during neoadjuvant chemotherapy (NAC) in cases with obstructing esophageal cancer. Under general anesthesia, the jejunum 20–30 cm distant from the Treitz ligament was pulled out through an extended umbilical laparoscopic incision and a jejunal tube was inserted to 30 cm. The loop of bowel was gently returned to the abdomen and the feeding tube was drawn through the abdominal wall via the left lower incision. The jejunum was then laparoscopically sutured to the anterior abdominal wall. Lap-J was performed in 26 cases. The median operative time was 82 min. The postoperative course was uneventful. Lap-J prior to NAC was not associated with a decrease in body weight or serum total protein during NAC, compared with patients who received NAC without Lap-J. This minimally invasive jejunostomy technique may be particularly useful in patients in whom endoscopic therapy is not feasible due to obstruction from upper gastrointestinal malignancies. PMID:26807238
Hwang, Na-Hyun; Lee, Yoon-Hwan; You, Hi-Jin; Yoon, Eul-Sik; Kim, Deok-Woo
2016-07-01
In recent years, endoscope-assisted transoral approach for condylar fracture treatment has attracted much attention. However, the surgical approach is technically challenging: the procedure requires specialized instruments and the surgeons experience a steep learning curve. During the transoral endoscopic (TE) approach several instruments are positioned through a narrow oral incision making endoscope maneuvering very difficult. For this reason, the authors changed the entry port of the endoscope from transoral to submandibular area through a small stab incision. The aim of this study is to assess the advantage of using the submandibular endoscopic intraoral approach (SEI).The SEI approach requires intraoral incision for fracture reduction and fixation, and 4 mm size submandibular stab incision for endoscope and traction wires. Fifteen patients with condyle neck and subcondyle fractures were operated under the submandibular approach and 15 patients with the same diagnosis were operated under the standard TE approach.The SEI approach allowed clear visualization of the posterior margin of the ramus and condyle, and the visual axis was parallel to the condyle ramus unit. The TE approach clearly shows the anterior margin of the condyle and the sigmoid notch. The surgical time of the SEI group was 128 minutes and the TE group was 120 minutes (P >0.05). All patients in the TE endoscope group were fixated with the trocar system, but only 2 lower neck fracture patients in the SEI group required a trocar. The other 13 subcondyle fractures were fixated with an angulated screw driver (P <0.05). There were no differences in complication and surgical outcomes.The submandibular endoscopic approach has an advantage of having more space with good visualization, and facilitated the use of an angulated screw driver.
Quick, J.E.
1991-01-01
The longest proposed suture zone in Saudi Arabia, the Nabitah suture, can be traced as a string of ophiolite complexes for 1200 km along the north-south axis of the Arabian Shield. Results of a field study in the north-central shield between 23?? and 26??N indicate that the Nabitah suture is indeed a major crustal discontinuity across which hundreds of kilometers of displacement may have occurred on north-south trending, subvertical faults of the Nabitah fault system. Although not a unique solution, many structures within and near these faults can be reconciled with transpression, i.e., convergent strike-slip, and syntectonic emplacement of calc-alkaline plutonic rocks. Transcurrent motion on the Nabitah fault system appears to have began prior to 710 Ma, was active circa 680 Ma, and terminated prior to significant left-lateral, strike slip on the Najd fault system, which began sometime after 650 Ma. Northwest-directed subduction in the eastern shield could have produced the observed association of calc-alkaline magmatism and left-lateral transpressive strike slip, and is consistent with interpretation of the Abt schist and sedimentary rocks of the Murdama group as relics of the associated accretionary wedge and fore-arc basin. ?? 1991.
NASA Astrophysics Data System (ADS)
Anderson, Dallas W.; Hsu, Tung M.; Halpern, Steven J.; Honaker, Arnold
1993-07-01
The ProClosureTM System (PCS) consists of a low power 1.32micrometers Nd:YAG laser coupled to a handheld disposable fiber optic device. The system has been designed to perform a wide range of tissue welding applications such as cosmetic skin closure,vascular surgery, and minimally invasive surgical procedures normally performed with sutures and staples. Utilizing a wavelength for tissue fusion that is least distracted by medium in the surgical field coupled with a computerized delivery system allows for a more precise application (+/- 5%) of laser energy to the tissue. The study design involved the micro-surgical anastomosis of twenty Sprague-Dawley rats (vas deferens) and twenty-one Sprague-Dawley rats (femoral arteries). Each rat is its own contralateral control. Laser repair time is approximately one-third that of conventional suturing. Postoperative dissection and burst strength testing was conducted at day 0, 1, 7, and 14. At each postoperative interval, the mean leak/burst strength for laser-assisted closure v. control, was markedly higher. The precise application of energy fluence resulting from ProClosure's computerized system yields an initial strength and a fluid static seal that is superior to conventional suture closure.
Skin closure with dye-enhanced laser welding and fibrinogen.
Wider, T M; Libutti, S K; Greenwald, D P; Oz, M C; Yager, J S; Treat, M R; Hugo, N E
1991-12-01
The topical application of wavelength-specific dye and fibrinogen has been used to enhance laser closure of vascular anastomoses. We compared the closure of skin incisions by two different dye-enhanced, fibrinogen-based laser welding systems [argon laser (power density 4.78 W/cm2) with fluorescein isothiocyanate dye (n = 32) and diode laser (power density 9.55 W/cm2) with indocyanine green dye (n = 32)] with closure by interrupted 5-0 nylon suture (n = 64) and examined tensile strength, hydroxyproline production, histology, and cosmesis. Two 3-cm full-thickness incisions were made on the shaved backs of 64 rats. One incision was closed with suture, whereas the other, after treatment with the appropriate dye, was welded with either argon- or diode-lasered fibrinogen. At postoperative days 5, 10, 15, and 28, the closure sites were harvested and sectioned for analysis. Initially, wounds closed with argon-lasered fibrinogen showed less inflammatory response, greater collagen production (34.61 +/- 0.74 mg/gm), and greater mean peak stress at rupture (64.85 lbs/in2) than those closed with suture (16.42 +/- 3.20 mg/gm, 26.68 lbs/in2) (p less than 0.05). By 15 days, both argon and diode laser closures are superior in strength and collagen production to suture closure (p less than 0.05). At 28 days, diode laser closures (1315.60 lbs/in2) are stronger than suture closures (998.09 lbs/in2), whereas both are stronger than argon laser closures (813.16 lbs/in2) (p less than 0.05). Cosmetically, argon-welded wounds consistently appeared finer and lacked cross-hatched suture scars.(ABSTRACT TRUNCATED AT 250 WORDS)
Treatment of chronic deltoid ligament injury using suture anchors.
Wang, Xu; Ma, Xin; Zhang, Chao; Wang, Chen; Huang, Jia-zhang
2014-08-01
To explore the efficacy of overlapping suture-anchor fixation for treatment of chronic deltoid ligament injury. Seventeen patients (11 men, 6 women of mean age 32.1 years [range, 18-58 years]) who had undergone surgery for chronic deltoid ligament injury from January 2007 to December 2011 were retrospectively analyzed. Preoperatively, they had undergone bilateral weight-bearing posterior-anterior radiographs, (MRI) and ultrasound examinations of the ankle. Ankle arthroscopy was performed to confirm the diagnosis, followed by surgery to clear intra-articular proliferating synovial tissues and remove cartilage debris and scar tissue. The deep layer of the deltoid ligament was sutured onto the tip of the medial malleolus and its superficial layer sutured onto its periosteum and fixed with suture anchors. American Orthopedic Foot and Ankle Society (AOFAS) scoring system for the ankle-hindfoot was used to evaluate the ankles pre- and post-operatively. The 17 patients were followed up for 12-34 months (mean 20.1 months). The angle between the long axes of the talus and first metatarsal and the hindfoot angle measured in a hindfoot alignment view (as described by Saltzman) were reduced from 5.4° ± 1.8° and 8.2° ± 2.6° preoperatively to 4.0° ± 0.9° and 5.3° ± 1.3° postoperatively, respectively. The mean AOFAS ankle-hindfoot score was 76.8 ± 7.0 preoperatively and 94.1 ± 3.3 at the last follow-up visit. Ten patients were scored as excellent, six as good, and one as fair. Pain was relieved in all patients and no patients had recurrent deltoid ligament injury. Using suture anchors to treat chronic deltoid ligament injury has relatively satisfactory outcomes. © 2014 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.
Sellei, R M; Bauer, E; Hofman, M; Kobbe, P; Lichte, P; Garrison, R L; Pape, H C; Horst, K
2015-12-01
Acute quadriceps tendon tears are infrequent injuries requiring surgical treatment. Improved stability after surgical repair may allow for earlier weight-bearing and range of motion. Therefore, a new implant was tested and compared with the "gold standard", using transosseous sutures. Quadriceps tendon tears were constructed using a cadaveric model of 12 fresh matched-pair specimens (aged 61-97; mean age: 82 years). The biomechanical testing compared non-absorbable suture anchors (Polyvinylidene fluoride) versus transosseous absorbable sutures (Polydioxanon). Following anatomic reconstruction, the repaired specimens were loaded until they failed (testing machine: Hounsfield H10KM, Redhill, United Kingdom; maximum force: 1000 N; load speed: 25 mm/min; maximum test length: 150 mm; pre-load: 5 N). Values for load until tear displacement, maximum load until complete failure of the construct (pullout or breakage of the sutures or anchors) and stiffness of the reconstruction were recorded. The stiffness found in the Polyvinylidene fluoride reconstruction (mean 9.83 N/mm) (standard deviation (SD) 7.75) showed a significant increase compared to the Polydioxanon reconstruction (mean 6.66 N/mm (SD 3.32); P=0.045). Transosseous fixation showed comparable results to the suture anchor system. There was no significant difference found in the maximum load to tear displacement (PVDF: 290.88 N (SD 106.01) vs. PDS: 266.75 N (SD 82.61); P=0.358). Using the Polyvinylidene fluoride thread showed comparable results to the established method in reconstruction of ruptured quadriceps tendon. Stiffness of the Polyvinylidene fluoride thread reconstruction was even greater than Polydioxanon thread. Improved stiffness may facilitate healing and is suggested as clinical relevance in reconstruction. Copyright © 2015 Elsevier B.V. All rights reserved.
Bernhardt, Sylvain; Nicolau, Stéphane A; Agnus, Vincent; Soler, Luc; Doignon, Christophe; Marescaux, Jacques
2016-05-01
The use of augmented reality in minimally invasive surgery has been the subject of much research for more than a decade. The endoscopic view of the surgical scene is typically augmented with a 3D model extracted from a preoperative acquisition. However, the organs of interest often present major changes in shape and location because of the pneumoperitoneum and patient displacement. There have been numerous attempts to compensate for this distortion between the pre- and intraoperative states. Some have attempted to recover the visible surface of the organ through image analysis and register it to the preoperative data, but this has proven insufficiently robust and may be problematic with large organs. A second approach is to introduce an intraoperative 3D imaging system as a transition. Hybrid operating rooms are becoming more and more popular, so this seems to be a viable solution, but current techniques require yet another external and constraining piece of apparatus such as an optical tracking system to determine the relationship between the intraoperative images and the endoscopic view. In this article, we propose a new approach to automatically register the reconstruction from an intraoperative CT acquisition with the static endoscopic view, by locating the endoscope tip in the volume data. We first describe our method to localize the endoscope orientation in the intraoperative image using standard image processing algorithms. Secondly, we highlight that the axis of the endoscope needs a specific calibration process to ensure proper registration accuracy. In the last section, we present quantitative and qualitative results proving the feasibility and the clinical potential of our approach. Copyright © 2016 Elsevier B.V. All rights reserved.
Magnetic anchor guidance for endoscopic submucosal dissection and other endoscopic procedures
Mortagy, Mohamed; Mehta, Neal; Parsi, Mansour A; Abe, Seiichiro; Stevens, Tyler; Vargo, John J; Saito, Yutaka; Bhatt, Amit
2017-01-01
Endoscopic submucosal dissection (ESD) is a well-established, minimally invasive treatment for superficial neoplasms of the gastrointestinal tract. The universal adoption of ESD has been limited by its slow learning curve, long procedure times, and high risk of complications. One technical challenge is the lack of a second hand that can provide traction, as in conventional surgery. Reliable tissue retraction that exposes the submucosal plane of dissection would allow for safer and more efficient dissection. Magnetic anchor guided endoscopic submucosal dissection (MAG-ESD) has potential benefits compared to other current traction methods. MAG-ESD offers dynamic tissue retraction independent of the endoscope mimicking a surgeon’s “second hand”. Two types of magnets can be used: electromagnets and permanent magnets. In this article we review the MAG-ESD technology, published work and studies of magnets in ESD. We also review the use of magnetic anchor guidance systems in natural orifice transluminal endoscopic surgery and the idea of magnetic non-contact retraction using surface ferromagentization. We discuss the current limitations, the future potential of MAG-ESD and the developments needed for adoption of this technology. PMID:28522906
Design and control of 2-axis tilting actuator for endoscope using ionic polymer metal composites
NASA Astrophysics Data System (ADS)
Kim, Sung-Joo; Kim, Chul-Jin; Park, No-Cheol; Yang, Hyun-Seok; Park, Young-Pil
2009-03-01
In field of endoscopy, in order to overcome limitation in conventional endoscopy, capsule endoscope has been developed and has been recently applied in medical field in hospital. However, since capsule endoscope moves passively through GI tract by peristalsis, it is not able to control direction of head including camera. It is possible to miss symptoms of disease. Therefore, in this thesis, 2-Axis Tilting Actuator for Endoscope, based on Ionic Polymer Metal Composites (IPMC), is presented. In order to apply to capsule endoscope, the actuator material should satisfy a size, low energy consumption and low working voltage. Since IPMC is emerging material that exhibits a large bending deflection at low voltage, consume low energy and it can be fabricated in any size or any shape, IPMC are selected as an actuator. The system tilts camera module of endoscope to reduce invisible area of the intestines and a goal of tilting angle is selected to be an angle of 5 degrees for each axis. In order to control tiling angle, LQR controller and the full order observer is designed.
Eun, Sang Soo; Lee, Sang Ho; Sabal, Luigi Andrew
2016-08-01
There are numerous methods for repairing posterior root tears of the medial meniscus (PRTMM). Repair techniques using suture anchors through a high posteromedial portal have been reported. The present study found that using a knotless suture anchor instead of suture anchor seemed easier and faster because it avoided passing the sutures through the meniscus and tying a knot in a small space. This study describes a knotless suture anchor technique through a high posteromedial portal, and its clinical results. Copyright © 2016 Elsevier B.V. All rights reserved.
[Auto-suture stapler EEA in surgery of the colon and rectum [author's transl)].
Thiede, A; Troidl, H; Poser, H; Jostarndt, L; Hamelmann, H
1980-01-01
The increasing use of auto-suture staplers for gastrointestinal anastomoses makes it necessary to test the value of this new method of suturing. In a "pilot study" the practicability, the tightness and permeability of the anastomosis and complications were tested and analysed in a total of 30 colon and rectal anastomoses using the EEA-suture gun. The results of 14 colon resections and 16 low anterior resections justify the further use of the EEA auto-suture apparatus and raise the question of a prospective controlled random study in which manual and mechanical machine sutured anastomoses are compared.
Griesser, H J; Chatelier, R C; Martin, C; Vasic, Z R; Gengenbach, T R; Jessup, G
2000-01-01
Fine elastomeric sutures intended for cardiovascular surgery can exhibit "stick-slip" behavior as they are pulled through tissue; the resulting oscillatory force can damage delicate tissue or cause sutures to snap. To eliminate this undesirable effect, sutures were surface-modified using a radiofrequency glow discharge in a vapor of either hexamethyldisiloxane or hexamethyldisilazane, to produce a thin polymeric coating on the suture. The same coatings were also deposited onto aluminized tape to facilitate their characterization by measurement of air/water contact angles and by X-ray photoelectron spectroscopy. Coatings from both monomers were found to be very hydrophobic. The hexamethyldisiloxane glow discharge coatings underwent negligible oxidation when stored in air, and thus remained stable over a shelf-life period akin to what may be required of sutures. The hexamethyldisilazane glow discharge coatings, in contrast, incorporated substantial amounts of oxygen over a 3-month period. The coatings did not measurably alter the tensile properties of the sutures. The frictional properties of coated sutures were assessed by measuring the dynamic friction between the suture and ovine myocardium. Both coatings were effective in removing the inherent stick-slip behavior of polybutester sutures in this model. The coatings remained intact after several passes and proved to be robust and efficacious under various strain regimes. Copyright 2000 John Wiley & Sons, Inc.
Yoshii, Shinji; Mabe, Katsuhiro; Nosho, Katsuhiko; Yamamoto, Hiroyuki; Yasui, Hiroshi; Okuda, Hiroyuki; Suzuki, Akira; Fujita, Masahiro; Sato, Toshihiro
2012-01-01
The clinical and endoscopic features of amyloid light-chain (AL) amyloidosis are diverse and mimic various other diseases. Endoscopically, few reports on submucosal hematomas of the gastrointestinal (GI) tract are available in the literature. Here, we report two cases of AL amyloidosis presenting as submucosal hematomas in the absence of clinical disease elsewhere in the body. The 2 cases were referred to our hospital because of hematochezia. The endoscopic findings in both cases were similar in submucosal hematoma formation. However, the clinical courses differed. In the first case, there was no evidence of systemic amyloidosis and the disease was conservatively managed. In the second case, the disease progressed to systemic amyloidosis and the patient died within a short time. We conclude that the endoscopic detection of a submucosal hematoma in the setting of GI bleeding should raise suspicion of AL amyloidosis. Referral to a hematologist should be done immediately for treatment while the involvement is limited to the GI tract. PMID:23125904
Miyasaka, M; Hirakawa, M; Nakamura, K; Tanaka, F; Mimori, K; Mori, M; Honda, H
2011-08-01
Nonerosive reflux disease (NERD) is classified into grade M (minimal change, endoscopically; erythema without sharp demarcation, whitish turbidity, and/or invisibility of vessels due to these findings) and grade N (normal) in the modified Los Angeles classification system in Japan. However, the classification of grades M and N NERD is not included in the original Los Angeles system because interobserver agreement for the conventional endoscopic diagnosis of grades M or N NERD is poor. Flexible spectral imaging color enhancement (FICE) is a virtual chromoendoscopy technique that enhances mucosal and vascular visibility. The aim of this study is to evaluate whether the endoscopic diagnosis of grades M or N NERD using FICE images is feasible. Between April 2006 and May 2008, 26 NERD patients and 31 controls were enrolled in the present study. First, an experienced endoscopist assessed the color pattern of minimal change in FICE images using conventional endoscopic images and FICE images side-by-side and comparing the proportion of minimal change between the two groups. Second, three blinded endoscopists assessed the presence or absence of minimal change in both groups using conventional endoscopic images and FICE images separately. Intraobserver variability was compared using McNemar's test, and interobserver agreement was described using the kappa value. Minimal changes, such as erythema and whitish turbidity, which were detected using conventional endoscopic images, showed up as navy blue and pink-white, respectively, in color using FICE images in the present FICE mode. The NERD group had a higher proportion of minimal change, compared with the control group (77% and 48%, respectively) (P= 0.033). In all three readers, the detection rates of minimal change using FICE images were greater than those using conventional endoscopic images (P= 0.025, <0.0001, and 0.034 for readers A, B, and C, respectively). The kappa values for all pairs of three readers using FICE images were between 0.683 and 0.812, while those using conventional endoscopic images were between 0.364 and 0.624. Thus, the endoscopic diagnosis of grades M or N NERD using FICE images is feasible and may improve interobserver agreement. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
Arthroscopically assisted acromioclavicular joint reconstruction.
Baumgarten, Keith M; Altchek, David W; Cordasco, Frank A
2006-02-01
Arthroscopically assisted acromioclavicular joint reconstruction avoids the large incisions necessary with open reconstructions. This acromioclavicular joint reconstruction technique via the subacromial space does not violate the rotator interval or require screw removal. The patient is placed in a modified beach-chair position. The arthroscope is placed into the subacromial space, and a bursectomy is performed through a lateral subacromial portal. The coracoacromial ligament is released from the acromion with an electrocautery and an arthroscopic elevator. A nonabsorbable suture is passed through the coracoacromial ligament with a suture passer, and an arthroscopic suture grasper is used to deliver both ends of the suture out through the lateral portal. The coracoid is identified and isolated using a radiofrequency ablator placed through the anterior portal while visualizing through the lateral portal. A percutaneous shuttle device is passed through the skin superomedial to the coracoid. The shuttle is visualized entering superior to the coracoid and is passed just medial to the coracoid. Once the tip of the shuttle can be visualized in the recess inferior to the coracoid, the shuttle loop is advanced. A suture grasper is used to deliver both ends of the shuttle out through the anterior portal. A semitendinosus allograft is used to reconstruct the coracoclavicular ligament. A nonabsorbable suture is passed through both ends of the allograft. Three strands of nonabsorbable suture are braided together. The tendon and the braided suture are shuttled around the coracoid. At this point, both the braided suture and the allograft tendon enter the anterior portal, wrap around the coracoid base, and exit the anterior portal. A 3-cm incision is made over the distal clavicle. A hole is drilled through the clavicle with a 5-mm drill. A loop of 22-gauge wire is passed through the hole in the clavicle, and a looped suture is shuttled through the hole. A curved clamp is used to create a tunnel from the acromioclavicular joint, under the deltoid, to the anterior portal. The ends of the braided suture and the tendon sutures are grasped by the clamp and pulled out the acromioclavicular joint incision. The limbs of the braided suture and the tendon suture that pass medial to the coracoid are shuttled through the hole in the clavicle using the looped suture that was previously passed through the clavicle. The acromioclavicular joint is reduced by pushing down on the distal clavicle with a bone tamp while simultaneously lifting the acromion upward by superiorly loading the humerus at the elbow. Once the acromioclavicular joint is reduced or slightly over-reduced, the braided suture is tied down securely. The acromioclavicular joint should remain reduced even after the manual reduction maneuver is released. The semitendinosus allograft is tensioned around the distal end of the clavicle and sutured to itself with a nonabsorbable suture. The released coracoacromial ligament is retrieved from the clavicular incision and sutured to the distal clavicle and semitendinosus allograft. The incision is closed in standard fashion, and a sling is applied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyd, James W.; Deters, Katherine A.; Brown, Richard S.
2011-09-01
Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the use of a shorter incision-one that may warrant only a single suture for closure. However, it is not known whether a single suture will sufficiently hold the incision closed when fish are decompressed and when outward pressure is placed on the surgical site during turbine passage through hydroelectric dams. The objective of this study was to evaluate the effectiveness of single-suture incision closures on five response variables in juvenile Chinook salmon Oncorhynchus tshawytscha that were subjected to simulated turbine passage. An acoustic transmitter (0.43more » g in air) and a passive integrated transponder tag (0.10 g in air) were implanted in each fish; the 6-mm incisions were closed with either one suture or two sutures. After exposure to simulated turbine passage, none of the fish exhibited expulsion of transmitters. In addition, the percentage of fish with suture tearing, incision tearing, or mortal injury did not differ between treatments. Expulsion of viscera through the incision was higher among fish that received one suture (12%) than among fish that received two sutures (1%). The higher incidence of visceral expulsion through single-suture incisions warrants concern. Consequently, for cases in which tagged juvenile salmonidsmay be exposed to turbine passage, we do not recommend the use of one suture to close 6-mm incisions associated with acoustic transmitter implantation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deters, Katherine A.; Brown, Richard S.; Carter, Kathleen M.
2010-05-01
This study assessed performance of seven suture types in subyearling Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Nonabsorbable (Ethilon) and absorbable (Monocryl) monofilament and nonabsorbable (Nurolon, silk) and absorbable (Vicryl, Vicryl Plus, Vicryl Rapide) braided sutures were used to close incisions in Chinook salmon. Monocryl exhibited greater suture retention than all other suture types 7 d after surgery. Both monofilament suture types were retained better than all braided suture types at 14 d. Incision openness and tag retention did not differ among suture types. Wound inflammation was similar for Ethilon, Monocryl, and Nurolon at 7 d. Wound ulceration wasmore » lower for Ethilon, Monocryl, and Nurolon than for all other suture types at 14 d post-surgery. Fish held in 12°C water had more desirable post-surgery healing characteristics (i.e., higher suture and tag retention and lower incision openness, wound inflammation, and ulceration) at 7 and 14 d after surgery than those held in 17°C water. The effect of surgeon was a significant predictor for all response variables at 7 d. This result emphasizes the importance of including surgeon as a variable in telemetry study analyses when multiple surgeons are used. Monocryl performed better with regard to post-surgery healing characteristics in the study fish. The overall results support the conclusion that Monocryl is the best suture material to close incisions created during surgical implantation of acoustic microtransmitters in subyearling Chinook salmon.« less
Advanced virtual endoscopy for endoscopic transsphenoidal pituitary surgery.
Wolfsberger, Stefan; Neubauer, André; Bühler, Katja; Wegenkittl, Rainer; Czech, Thomas; Gentzsch, Stephan; Böcher-Schwarz, Hans-Gerd; Knosp, Engelbert
2006-11-01
Virtual endoscopy (vE) is the navigation of a camera through a virtual anatomical space that is computationally reconstructed from radiological image data. Inside this three-dimensional space, arbitrary movements and adaptations of viewing parameters are possible. Thereby, vE can be used for noninvasive diagnostic purposes and for simulation of surgical tasks. This article describes the development of an advanced system of vE for endoscopic transsphenoidal pituitary surgery and its application to teaching, training, and in the routine clinical setting. The vE system was applied to a series of 35 patients with pituitary pathology (32 adenomas, three Rathke's cleft cysts) operated endoscopically via the transsphenoidal route at the Department of Neurosurgery of the Medical University Vienna between 2004 and 2006. The virtual endoscopic images correlated well with the intraoperative view. For the transsphenoidal approach, vE improved intraoperative orientation by depicting anatomical landmarks and variations. For planning a safe and tailored opening of the sellar floor, transparent visualization of the pituitary adenoma and the normal gland in relation to the internal carotid arteries was useful. According to our experience, vE can be a valuable tool for endoscopic transsphenoidal pituitary surgery for training purposes and preoperative planning. For the novice, it can act as a simulator for endoscopic anatomy and for training surgical tasks. For the experienced pituitary surgeon, vE can depict the individual patient's anatomy, and may, therefore, improve intraoperative orientation. By prospectively visualizing unpredictable anatomical variations, vE may increase the safety of this surgical procedure.
The B-Lynch uterine brace suture, and a bit of this and a bit of that...
Karoshi, Mahantesh
2010-03-01
The widespread application of the B-Lynch brace suture to control postpartum hemorrhage has sparked interest in a variety of adjunctive methods, used alone or in combination, to control uterine bleeding. Although the B-Lynch brace suture has been used with good results throughout the world, failures can and do occur in rare instances, especially when the suture is incorrectly placed for use for an inappropriate indication. Four reports of additional methods to control postpartum hemorrhage are published in this issue of IJGO. Three use the B-Lynch brace suture combined with other techniques. The need for additional techniques reminds the reader of the importance of proper suture application for proper indication. Potential reasons for failure of the B-Lynch suture are provided.
Burger, C; Kabir, K; Mueller, M; Rangger, C; Minor, T; Tolba, R H
2006-01-01
In an ovine meniscal repair model, the patellofemoral (PF) osteoarthritis due to a non-sutured tear or failed repair was investigated. A radial meniscus tear was either sutured with polydioxanone (PDS), with a slow degrading polylactide long-term suture(LTS) or left without treatment. Knee joint cartilage in the PF and medial compartment was evaluated compared to normal knees (healthy controls). Retropatellar osteoarthritis in the non-sutured and sutured animals was intense in contrast to the control knees after 6 months in all groups (p < 0.001), and after 12 months in the PDS group (p < 0.001), LTS group and non-sutured animals (p < 0.05). Non-sutured meniscus tears and failed repair lead fast to intense PF osteoarthritis corresponding with tibial damage of the injured compartment.
In vitro evaluation of novel antimicrobial coatings for surgical sutures using octenidine.
Obermeier, A; Schneider, J; Föhr, P; Wehner, S; Kühn, K-D; Stemberger, A; Schieker, M; Burgkart, R
2015-09-24
Sutures colonized by bacteria represent a challenge in surgery due to their potential to cause surgical site infections. In order to reduce these type of infections antimicrobially coated surgical sutures are currently under development. In this study, we investigated the antimicrobial drug octenidine as a coating agent for surgical sutures. To achieve high antimicrobial efficacy and required biocompatibility for medical devices, we focused on optimizing octenidine coatings based on fatty acids. For this purpose, antimicrobial sutures were prepared with either octenidine-laurate or octenidine-palmitate at 11, 22, and 33 μg/cm drug concentration normalized per length of sutures. Octenidine containing sutures were compared to the commercial triclosan-coated suture Vicryl® Plus. The release of octenidine into aqueous solution was analyzed and long-term antimicrobial efficacy was assessed via agar diffusion tests using Staphylococcus aureus. For determining biocompatibility, cytotoxicity assays (WST-1) were performed using L-929 mouse fibroblasts. In a 7 days elution experiment, octenidine-palmitate coated sutures demonstrated much slower drug release (11 μg/cm: 7%; 22 μg/cm: 5%; 33 μg/cm: 33%) than octenidine-laurate sutures (11 μg/cm: 82%; 22 μg/cm: 88%; 33 μg/cm: 87%). Furthermore sutures at 11 μg/cm drug content were associated with acceptable cytotoxicity according to ISO 10993-5 standard and showed, similar to Vicryl® Plus, relevant efficacy to inhibit surrounding bacterial growth for up to 9 days. Octenidine coated sutures with a concentration of 11 μg/cm revealed high antimicrobial efficacy and biocompatibility. Due to their delayed release, palmitate carriers should be preferred. Such coatings are candidates for clinical testing in regard to their safety and efficacy.
Mechanical Strength of the Side-to-Side Versus Pulvertaft Weave Tendon Repair
Brown, Stephen H. M.; Hentzen, Eric R.; Kwan, Alan; Ward, Samuel R.; Fridén, Jan; Lieber, Richard L.
2010-01-01
Purpose The side-to-side (SS) tendon suture technique was designed to function as a repair that permits immediate post-operative activation and mobilization of a transferred muscle. This study was designed to test the strength and stiffness of the SS technique against a variation of the Pulvertaft (PT) repair technique. Methods Flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) tendons were harvested from four fresh cadavers and used as a model system. Seven SS and six PT repairs were performed using the FDS as the donor and the FDP as the recipient tendon. For SS repairs, the FDS was woven through one incision in the FDP, and was joined with four cross-stitch running sutures down both sides, and one double-loop suture at each tendon free end; for PT repairs, FDS was woven through three incisions in FDP, joined with a double-loop suture at both ends of the overlap, and four evenly spaced mattress sutures between the ends. Tendon repairs were placed in a tensile testing machine, pre-conditioned and tested to failure. Results There were no statistically significant differences in cross-sectional area (p=0.99) or initial length (p=0.93) between SS and PT repairs. Therefore, all comparisons between methods were made using measures of loads and deformations, rather than stresses and strains.. All failures occurred in the repair region, rather than at the clamps. However, failure mechanisms were different between the two techniques—PT repairs failed by the suture knots either slipping or pulling through the tendon material, followed by the FDS tendon pulling through the FDP tendon; SS repairs failed by shearing of fibers within the FDS. Load at first failure (p < 0.01), ultimate load (p < 0.001), and repair stiffness (p < 0.05) were all significantly different between SS and PT techniques; in all cases the mean value for SS was higher than for PT. Discussion The SS repair, using a cross-stitch suture technique, was significantly stronger and stiffer compared to the PT repair using a mattress suture technique. This suggests that using SS repairs could enable patients to load the repair soon after surgery. Ultimately, this should reduce the risk of developing adhesions and result in improved functional outcome and fewer complications in the acute post-operative period. Future work will address the specific mechanisms (for example, suture-throw technique, tendon-weave technique) that underlie the improved strength and stiffness of the SS repair. PMID:20223604
Advances in Suture Material for Obstetric and Gynecologic Surgery
Greenberg, James A; Clark, Rachel M
2009-01-01
Despite millennia of experience with wound closure biomaterials, no study or surgeon has yet identified the perfect suture for all situations. Tissue characteristics, tensile strength, reactivity, absorption rates, and handling properties should be taken into account when selecting a wound closure suture. This review discusses the wound healing process and the biomechanical properties of currently available suture materials to better understand how to choose suture material in obstetrics and gynecology. PMID:19826572
The mechanics of endoscope disinfection.
Babb, J R; Bradley, C R
1991-06-01
The decontamination of flexible fibreoptic endoscopes has considerably improved in recent years. This is mainly due to the introduction of instruments with more accessible channels, the use of automated washer disinfectors and a greater awareness of the problems associated with disinfection. Unfortunately the most widely used and effective disinfectant is 2% glutaraldehyde and this is toxic, irritant and sensitizing. With the implementation of Control of Substances Hazardous to Health legislation, strict environmental controls are required to reduce skin contact and vapour inhalation. Alcohol is probably the most suitable alternative disinfectant at present but it is flammable and cannot be used in automated systems. Other agents are either insufficiently effective or corrosive. Autoclavable or heat tolerant rigid endoscopes are now available but flexible endoscopes will not tolerate heat disinfection temperatures.
Calibration procedures of the Tore-Supra infrared endoscopes
NASA Astrophysics Data System (ADS)
Desgranges, C.; Jouve, M.; Balorin, C.; Reichle, R.; Firdaouss, M.; Lipa, M.; Chantant, M.; Gardarein, J. L.; Saille, A.; Loarer, T.
2018-01-01
Five endoscopes equipped with infrared cameras working in the medium infrared range (3-5 μm) are installed on the controlled thermonuclear fusion research device Tore-Supra. These endoscopes aim at monitoring the plasma facing components surface temperature to prevent their overheating. Signals delivered by infrared cameras through endoscopes are analysed and used on the one hand through a real time feedback control loop acting on the heating systems of the plasma to decrease plasma facing components surface temperatures when necessary, on the other hand for physics studies such as determination of the incoming heat flux . To ensure these two roles a very accurate knowledge of the absolute surface temperatures is mandatory. Consequently the infrared endoscopes must be calibrated through a very careful procedure. This means determining their transmission coefficients which is a delicate operation. Methods to calibrate infrared endoscopes during the shutdown period of the Tore-Supra machine will be presented. As they do not allow determining the possible transmittances evolution during operation an in-situ method is presented. It permits the validation of the calibration performed in laboratory as well as the monitoring of their evolution during machine operation. This is possible by the use of the endoscope shutter and a dedicated plasma scenario developed to heat it. Possible improvements of this method are briefly evoked.
Ectocranial suture fusion in primates: pattern and phylogeny.
Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I
2014-03-01
Patterns of ectocranial suture fusion among Primates are subject to species-specific variation. In this study, we used Guttman Scaling to compare modal progression of ectocranial suture fusion among Hominidae (Homo, Pan, Gorilla, and Pongo), Hylobates, and Cercopithecidae (Macaca and Papio) groups. Our hypothesis is that suture fusion patterns should reflect their evolutionary relationship. For the lateral-anterior suture sites there appear to be three major patterns of fusion, one shared by Homo-Pan-Gorilla, anterior to posterior; one shared by Pongo and Hylobates, superior to inferior; and one shared by Cercopithecidae, posterior to anterior. For the vault suture pattern, the Hominidae groups reflect the known phylogeny. The data for Hylobates and Cercopithecidae groups is less clear. The vault suture site termination pattern of Papio is similar to that reported for Gorilla and Pongo. Thus, it may be that some suture sites are under larger genetic influence for patterns of fusion, while others are influenced by environmental/biomechanic influences. Copyright © 2013 Wiley Periodicals, Inc.
Imaging pancreatobiliary ductal system with optical coherence tomography: A review
Mahmud, Mohammad S; May, Gray R; Kamal, Mohammad M; Khwaja, Ahmed S; Sun, Carry; Vitkin, Alex; Yang, Victor XD
2013-01-01
An accurate, noninvasive and cost-effective method of in situ tissue evaluation during endoscopy would be highly advantageous for the detection of dysplasia or early cancer and for identifying different disease stages. Optical coherence tomography (OCT) is a noninvasive, high-resolution (1-10 μm) emerging optical imaging method with potential for identifying microscopic subsurface features in the pancreatic and biliary ductal system. Tissue microstructure of pancreaticobiliary ductal system has been successfully imaged by inserting an OCT probe through a standard endoscope operative channel. High-resolution OCT images and the technique’s endoscopic compatibility have allowed for the microstructural diagnostic of the pancreatobiliary diseases. In this review, we discussed currently available pancreaticobiliary ductal imaging systems to assess the pancreatobiliary tissue microstructure and to evaluate varieties of pancreaticobiliary disorders and diseases. Results show that OCT can improve the quality of images of pancreatobiliary system during endoscopic retrograde cholangiopancheatography procedure, which may be important in distinguishing between the neoplastic and non-neoplastic lesions. PMID:24255746
Sclera-directed knot technique for securing an encircling band in retinal surgery.
Bartov, E; Ginsburg, L H; Ashkenazi, I; Treister, G
1991-10-01
The protruding ends of sutures used to secure the ends of the silicone rubber band placed during many retinal surgical procedures may cause postsurgical irritation, since with presently used suturing techniques, the knot of the suture remains on top of the band, facing the conjunctiva. We describe a suturing technique which, by inverting the band when suturing its ends and then allowing the band to return to its original position, places the knot on the undersurface of the band, against the sclera. Thus, no protruding suture ends are left facing the conjunctiva and the irritation resulting from such a protrusion is averted.
Olah, Z
1979-11-01
The present paper deals with the results of 20 eyes of experimentally operated laboratory animals, whose perforating wounds (of cornea and those of sclerocorneal region) have been suturated with a new type of absorbable synthetic suture material "Dexon" thickness being 6-0. The synthetic absorbable suture material "Dexon" is made of polyglycol acid, and it has been introduced to market by the firm Davis and Geck (U.S.A.). The inflammatory tissue reaction to the presence of the suture material "Dexon" is prominent and can by compared to the reaction to chromic resorbable suture materials (catgut or collagen). The suture material "Dexon" start to resorb in the course of the 2nd-3rd weeks after operation. The suture material "Dexon" can be used at an advantage in the operation where it is possible to cover the knots by a conjuctival lobe (in sclerocorneal region or in strabismus surgery) in this way the tendency to overgrowing of epithelial cells along the suture channels can be prevented. The "Dexon" material is sufficiently flexible and firm and has no antigenic properties, therefore it appears very prospective for ophthalmosurgery.
Effect of human urine on the tensile strength of sutures used for hypospadias surgery.
Kerstein, Ryan L; Sedaghati, Tina; Seifalian, Alexander M; Kang, Norbert
2013-06-01
Hypospadias is the most common congenital condition affecting between 1 in 250 and 300 live births. Even in experienced hands, surgery to repair this congenital defect can have a high complication rate. Wound dehiscence is reported to occur in 5% and fistula formation in 6%-40% depending on technique. The choice of suture material has been shown to affect the complication rate although there is (currently) no consensus about the best suture material to use. Ideally, the sutures used for urethroplasty should be absorbable while maintaining sufficient mechanical strength to support the wounds until they are self-supporting and able to resist urinary flow. Previous studies have compared the effects of human urine on different suture materials especially catgut. However, catgut is now banned in Europe. Our study examined the tensile and breaking strength as well as rate of degradation for four types of absorbable suture now commonly used for hypospadias repairs in the UK. We examined the effect of prolonged storage (up to 27 days) in human urine on 6/0 gauge Vicryl, Vicryl Rapide, Monocryl and polydioxanone (PDS) sutures. These four suture materials are commonly used by the senior plastic consultant surgeon (NK) for hypospadias repairs. 50 mm sections of these suture materials were stored in either urine or saline as control. At specified time points, each suture was placed in a uniaxial load testing machine to assess the stress-strain profile and the mechanical load required to break the suture was measured. Exposure to urine reduced the tensile and breaking strength of all the suture materials tested. PDS demonstrated the greatest resilience. Vicryl Rapide was the weakest suture and degraded completely by day 6. Vicryl and Monocryl had similar degradation profiles, but Vicryl retained more of its tensile strength for longer. There is a balance to be struck between the duration that a suture material must remain in any surgical wound and the risk that it causes foreign body effects. The results of this study suggest that Vicryl has the best characteristics for urethroplasty of the four suture materials tested. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
A novel endoscopic fluorescent band ligation method for tumor localization.
Hyun, Jong Hee; Kim, Seok-Ki; Kim, Kwang Gi; Kim, Hong Rae; Lee, Hyun Min; Park, Sunup; Kim, Sung Chun; Choi, Yongdoo; Sohn, Dae Kyung
2016-10-01
Accurate tumor localization is essential for minimally invasive surgery. This study describes the development of a novel endoscopic fluorescent band ligation method for the rapid and accurate identification of tumor sites during surgery. The method utilized a fluorescent rubber band, made of indocyanine green (ICG) and a liquid rubber solution mixture, as well as a near-infrared fluorescence laparoscopic system with a dual light source using a high-powered light-emitting diode (LED) and a 785-nm laser diode. The fluorescent rubber bands were endoscopically placed on the mucosae of porcine stomachs and colons. During subsequent conventional laparoscopic stomach and colon surgery, the fluorescent bands were assayed using the near-infrared fluorescence laparoscopy system. The locations of the fluorescent clips were clearly identified on the fluorescence images in real time. The system was able to distinguish the two or three bands marked on the mucosal surfaces of the stomach and colon. Resection margins around the fluorescent bands were sufficient in the resected specimens obtained during stomach and colon surgery. These novel endoscopic fluorescent bands could be rapidly and accurately localized during stomach and colon surgery. Use of these bands may make possible the excision of exact target sites during minimally invasive gastrointestinal surgery.
Britt, Rebecca C; Scerbo, Mark W; Montano, Michael; Kennedy, Rebecca A; Prytz, Erik; Stefanidis, Dimitrios
2015-11-01
A spatial secondary task developed by the authors was used to measure the mental workload of the participant when transferring suturing skills from a box simulator to more realistic surgical conditions using a fresh cadaver. We hypothesized that laparoscopic suturing on genuine bowel would be more challenging than on the Fundamentals of Laparoscopic Surgery (FLS)-simulated bowel as reflected in differences on both suturing and secondary task scores. We trained 14 surgical assistant students to FLS proficiency in intracorporeal suturing. Participants practiced suturing on the FLS box for 30 minutes and then were tested on both the FLS box and the bowel of a fresh cadaver using the spatial, secondary dual-task conditions developed by the authors. Suturing times increased by >333% when moving from the FLS platform to the cadaver F(1,13) = 44.04, P < .001. The increased completion times were accompanied by a 70% decrease in secondary task scores, F(1,13) = 21.21, P < .001. The mental workload associated with intracorporeal suturing increases dramatically when trainees transfer from the FLS platform to human tissue under more realistic conditions of suturing. The increase in mental workload is indexed by both an increase in suturing times and a decrease in the ability to attend to the secondary task. Copyright © 2015 Elsevier Inc. All rights reserved.
Ram, Jagat; Gupta, Nishant; Chaudhary, Manish; Verma, Neelam
2013-01-01
Background: A new emerging complication of trans-scleral fixation of posterior chamber (PC) intraocular lens (IOL) with polypropylene suture is high rates of spontaneous dislocation of the IOL due to disintegration or breakage of suture. Materials: We report a new surgical technique of trans-scleral fixation of posterior chamber intraocular lens (SF PCIOL) with steel suture to eliminate the complication of dislocation of IOL fixed with polypropylene suture in one adult and a child. Results: We successfully achieved stable fixation and good centration of IOL after SF PCIOL with steel suture in these patient having inadequate posterior capsular support. Both eyes achieved best corrected visual acuity 20/40 at 18 months follow-up. Conclusions: Steel suture is a viable option for trans-scleral fixation of posterior chamber intraocular lens. PMID:23619504
Development of a needle driver with multiple degrees of freedom for neonatal laparoscopic surgery.
Ishimaru, Tetsuya; Takazawa, Shinya; Uchida, Hiroo; Kawashima, Hiroshi; Fujii, Masahiro; Harada, Kanako; Sugita, Naohiko; Mitsuishi, Mamoru; Iwanaka, Tadashi
2013-07-01
The aims of this study were to develop a thin needle driver with multiple degrees of freedom and to evaluate its efficacy in multidirectional suturing compared with a conventional needle driver. The tip (15 mm) of the novel user-friendly needle driver (3.5 mm in diameter) has three degrees of freedom for grasping, rotation, and deflection. Six pediatric surgeons performed two kinds of suturing tasks in a dry box: three stitches in continuous suturing that were perpendicular or parallel to the insertion direction of the instrument, first using the novel instrument, then using a conventional instrument, and finally using the novel instrument again. The accuracy of insertion and exit compared with the target points and the procedure time were measured. In the conventional and novel procedures the mean gaps from the insertion point to the target in perpendicular suturing were 0.8 mm and 0.7 mm, respectively; in parallel suturing they were 0.8 mm and 0.6 mm, respectively. The mean gaps from the exit point to the target in perpendicular suturing were 0.6 mm and 0.6 mm for conventional and novel procedures, respectively; in parallel suturing they were 0.6 mm and 0.8 mm, respectively. The procedure time for perpendicular suturing was 33 seconds and 64 seconds for conventional and novel procedures, respectively (P=.02); for parallel suturing it was 114 seconds and 91 seconds, respectively. Our novel needle driver maintained accuracy of suturing; parallel suturing with the novel driver may be easier than with the conventional one.
Strain in the Braincase and Its Sutures During Function
Herring, Susan W.; Teng, Shengyi
2010-01-01
The skull is distinguished from other parts of the skeleton by its composite construction. The sutures between bony elements provide for interstitial growth of the cranium, but at the same time they alter the transmission of stress and strain through the skull. Strain gages were bonded to the frontal and parietal bones of miniature pigs and across the interfrontal, interparietal and coronal sutures. Strains were recorded 1) during natural mastication in conjunction with electromyographic activity from the jaw muscles and 2) during stimulation of various cranial muscles in anesthetized animals. Vault sutures exhibited vastly higher strains than did the adjoining bones. Further, bone strain primarily reflected torsion of the braincase set up by asymmetrical muscle contraction; the tensile axis alternated between +45° and −45° depending on which diagonal masseter/temporalis pair was most active. However, suture strains were not related to overall torsion but instead were responses to local muscle actions. Only the coronal suture showed significant strain (tension) during jaw opening; this was caused by the contraction of neck muscles. All sutures showed strain during jaw closing, but polarity depended on the pattern of muscle usage. For example, masseter contraction tensed the coronal suture and the anterior part of the interfrontal suture, whereas the temporalis caused compression in these locations. Peak tensile strains were larger than peak compressive strains. Histology suggested that the skull is bent at the sutures, with the ectocranial surface tensed and the endocranial surface predominantly compressed. Collectively, these results indicate that skulls with patent sutures should be analyzed as complexes of independent parts rather than solid structures. PMID:10918130
Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism
Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S
2013-01-01
Aims In a previous study, we proposed that corneal topography performed 30–40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. Methods 10/0 nylon interrupted sutures were placed, to secure the graft–host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30–40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4–6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Results Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). Conclusion SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty. PMID:23743526