Sample records for endovascular patch welding

  1. Endovascular Patch Embolization for Blood Blister-Like Aneurysms in Dorsal Segment of Internal Carotid Artery.

    PubMed

    Hao, Xudong; Li, Guilin; Ren, Jian; Li, Jingwei; He, Chuan; Zhang, Hong-Qi

    2018-05-01

    Blood blister-like aneurysms (BBAs) in the dorsal segment of the internal carotid artery are fragile and difficult to treat, and the optimal treatment for BBAs is still controversial. We report clinical and angiographic results with procedural details for the treatment of BBA by using the endovascular patch embolization method. We retrospectively reviewed patients who presented with subarachnoid hemorrhage caused by internal carotid artery-BBAs and were treated with the endovascular patch embolization method in our center from October 2011 to March 2015. Clinical records, angiographic findings, procedural details, and follow-up results are reported in this study. Eight patients were enrolled in this study. All patients were treated with the endovascular patch embolization method. The key points of this method are step-by-step stent deployment and swaying of the microcatheter to coil the aneurysm sac and the wedge-shaped space between the stent and parent artery and, thereby, in the aneurysm sac and parent artery around the aneurysm neck. When the stent is completely deployed, an endovascular patch is formed and anchored around the neck of the BBA. The procedure was successful in all cases. No acute complications developed in any case. No rerupture or recurrence of the BBA occurred during follow-up. One patient with Hunt-Hess V subarachnoid hemorrhage died of multiple organ failure 4 months post treatment. Another patient died of intracranial infection related to the ventricle-peritoneal shunt. The remaining 6 patients had good clinical outcomes (modified Rankin Scale score of zero). Endovascular patch embolization is an improvement on stent-assisted coil embolization, which could be successfully performed only with extensive skill and patience. Endovascular patch embolization could be an effective method in BBA treatment. However, its efficacy and safety should be verified in a larger patient cohort and long-term follow-up study. Copyright © 2018. Published by Elsevier Inc.

  2. Dye-enhanced protein solders and patches in laser-assisted tissue welding.

    PubMed

    Small, W; Heredia, N J; Maitland, D J; Da Silva, L B; Matthews, D L

    1997-01-01

    This study examines the use of dye-enhanced protein bonding agents in 805 nm diode laser-assisted tissue welding. A comparison of an albumin liquid solder and collagen solid-matrix patches used to repair arteriotomies in an in vitro porcine model is presented. Extrinsic bonding media in the form of solders and patches have been used to enhance the practice of laser tissue welding. Preferential absorption of the laser wavelength has been achieved by the incorporation of chromophores. Both the solder and the patch included indocyanine green dye (ICG) to absorb the 805 nm continuous-wave diode laser light used to perform the welds. Solder-mediated welds were divided into two groups (high power/short exposure and low power/long exposure), and the patches were divided into three thickness groups ranging from 0.1 to 1.3 mm. The power used to activate the patches was constant, but the exposure time was increased with patch thickness. Burst pressure results indicated that solder-mediated and patched welds yielded similar average burst strengths in most cases, but the patches provided a higher success rate (i.e., more often exceeded 150 mmHg) and were more consistent (i.e., smaller standard deviation) than the solder. The strongest welds were obtained using 1.0-1.3 mm thick patches, while the high power/short exposure solder group was the weakest. Though the solder and patches yielded similar acute weld strengths, the solid-matrix patches facilitated the welding process and provided consistently strong welds. The material properties of the extrinsic agents influenced their performance.

  3. Study made to establish parameters and limitations of explosive welding

    NASA Technical Reports Server (NTRS)

    Polhemus, F. C.

    1967-01-01

    It is theorized that metal jetting must be present for welding to occur, therefore an explosive weld interface may indicate the relation between the metal jet velocity and shock wave velocity in welding. Parameters for effecting explosive welding in patches of 3 or 4 inches in diameter were established, and found applicable to explosive welding of patches of various sizes.

  4. Intraluminal tissue welding for anastomosis

    DOEpatents

    Glinsky, M.; London, R.; Zimmerman, G.; Jacques, S.

    1998-10-27

    A method and device are provided for performing intraluminal tissue welding for anastomosis of a hollow organ. A retractable catheter assembly is delivered through the hollow organ and consists of a catheter connected to an optical fiber, an inflatable balloon, and a biocompatible patch mounted on the balloon. The disconnected ends of the hollow organ are brought together on the catheter assembly, and upon inflation of the balloon, the free ends are held together on the balloon to form a continuous channel while the patch is deployed against the inner wall of the hollow organ. The ends are joined or ``welded`` using laser radiation transmitted through the optical fiber to the patch. A thin layer of a light-absorbing dye on the patch can provide a target for welding. The patch may also contain a bonding agent to strengthen the bond. The laser radiation delivered has a pulse profile to minimize tissue damage. 8 figs.

  5. Intraluminal tissue welding for anastomosis

    DOEpatents

    Glinsky, Michael; London, Richard; Zimmerman, George; Jacques, Steven

    1998-10-27

    A method and device are provided for performing intraluminal tissue welding for anastomosis of a hollow organ. A retractable catheter assembly is delivered through the hollow organ and consists of a catheter connected to an optical fiber, an inflatable balloon, and a biocompatible patch mounted on the balloon. The disconnected ends of the hollow organ are brought together on the catheter assembly, and upon inflation of the balloon, the free ends are held together on the balloon to form a continuous channel while the patch is deployed against the inner wall of the hollow organ. The ends are joined or "welded" using laser radiation transmitted through the optical fiber to the patch. A thin layer of a light-absorbing dye on the patch can provide a target for welding. The patch may also contain a bonding agent to strengthen the bond. The laser radiation delivered has a pulse profile to minimize tissue damage.

  6. Endovascular treatment of false-aneurysm ten years after dacron patch aortoplasty for coarctation of the aortic isthmus. Report of a case.

    PubMed

    Illuminati, Giulio; Pacilè, Maria Antonietta; Palumbo, Piergaspare; Salvatori, Filippo Maria; Vietri, Francesco

    2013-01-01

    False aneurysm degeneration is a known complication of patch aortoplasty for coarctation of the aortic isthmus. Open surgical treatment consists of prosthetic graft repair of the involved aorta, often requires circulatory arrest to achieve a safe proximal aortic control and perform proximal anastomosis, and finally is associated with substantial perioperative morbidity. Endografting of the diseased aorta is a valuable alternative to open repair, when feasible, with good short and long term results. We now report one more case of false aneurysm ten years after Dacron patch aortoplasty for isthmic coarctation in a 26-year-old woman, successfully treated by endovascular repair via the left common iliac artery, and a complete exclusion of the aneurysm at two year follow-up.

  7. Bronchial reactions to exposure to welding fumes.

    PubMed Central

    Contreras, G R; Chan-Yeung, M

    1997-01-01

    OBJECTIVES: To study the airway response and its mechanism to welding fumes in six welders with respiratory symptoms. METHODS: Methacholine and welding challenge tests were carried out. The concentration of welding fumes during the exposure test was measured. On two subjects who developed bronchoconstricition to welding challenge, additional tests were carried out including prick, patch, and inhalation challenges with metal salt solutions. RESULTS: Three subjects developed immediate bronchial reaction to exposure to welding fume; one to mild steel and stainless steel welding, another to mild steel and galvanised welding, and one only to galvanised welding. They all had a moderate to pronounced degree of non-specific bronchial hyperresponsiveness. The concentration of fumes during welding tests, particularly to galvanised welding, was high. An inhalation challenge test with zinc chloride salt solution in two subjects who reacted to galvanised welding was negative. Prick and patch tests with zinc chloride were also negative. CONCLUSION: The airway response to welding in these subjects is non-specific and is due to irritation rather than to sensitisation. PMID:9538358

  8. Bronchial reactions to exposure to welding fumes.

    PubMed

    Contreras, G R; Chan-Yeung, M

    1997-11-01

    To study the airway response and its mechanism to welding fumes in six welders with respiratory symptoms. Methacholine and welding challenge tests were carried out. The concentration of welding fumes during the exposure test was measured. On two subjects who developed bronchoconstricition to welding challenge, additional tests were carried out including prick, patch, and inhalation challenges with metal salt solutions. Three subjects developed immediate bronchial reaction to exposure to welding fume; one to mild steel and stainless steel welding, another to mild steel and galvanised welding, and one only to galvanised welding. They all had a moderate to pronounced degree of non-specific bronchial hyperresponsiveness. The concentration of fumes during welding tests, particularly to galvanised welding, was high. An inhalation challenge test with zinc chloride salt solution in two subjects who reacted to galvanised welding was negative. Prick and patch tests with zinc chloride were also negative. The airway response to welding in these subjects is non-specific and is due to irritation rather than to sensitisation.

  9. A new technique for the closure of the lens capsule by laser welding.

    PubMed

    Pini, Roberto; Rossi, Francesca; Menabuoni, Luca; Lenzetti, Ivo; Yoo, Sonia; Parel, Jean-Marie

    2008-01-01

    A new method is presented for the closure of the lens capsule based on laser welding of suitably prepared patches of anterior capsular tissue. Experiments were performed in freshly enucleated porcine eyes. The patches were previously stained with a solution of indocyanine green in sterile water and then welded on the recipient capsule by means of diode laser radiation at 810 nm. The welded tissue revealed mechanical properties comparable to those of healthy tissue. This technique is proposed to repair capsular breaks and to provide the closure of the capsulorhexis in lens refilling procedures.

  10. Experimental and computational laser tissue welding using a protein patch.

    PubMed

    Small, W; Heredia, N J; Maitland, D J; Eder, D C; Celliers, P M; Da Silva, L B; London, R A; Matthews, D L

    1998-01-01

    An in vitro study of laser tissue welding mediated with a dye-enhanced protein patch was conducted. Fresh sections of porcine aorta were used for the experiments. Arteriotomies were treated using an indocyanine green dye-enhanced collagen patch activated by an 805-nm continuous-wave fiber-delivered diode laser. Temperature histories of the surface of the weld site were obtained using a hollow glass optical fiber-based two-color infrared thermometer. The experimental effort was complemented by simulations with the LATIS (LAser-TISsue) computer code, which uses coupled Monte Carlo, thermal transport, and mass transport models. Comparison of simulated and experimental thermal data indicated that evaporative cooling clamped the surface temperature of the weld site below 100 °C. For fluences of approximately 200 J/cm2, peak surface temperatures averaged 74°C and acute burst strengths consistently exceeded 0.14×106 dyn/cm (hoop tension). The combination of experimental and simulation results showed that the inclusion of water transport and evaporative losses in the computer code has a significant impact on the thermal distributions and hydration levels throughout the tissue volume. The solid-matrix protein patch provided a means of controllable energy delivery and yielded consistently strong welds. © 1998 Society of Photo-Optical Instrumentation Engineers.

  11. Arc Welding of Mg Alloys: Oxide Films, Irregular Weld Shape and Liquation Cracking

    NASA Astrophysics Data System (ADS)

    Chai, Xiao

    The use of Mg alloys for vehicle weight reduction has been increasing rapidly worldwide. Gas-metal arc welding (GMAW) has the potential for mass-production welding of Mg alloys. Recently, the University of Wisconsin demonstrated in bead-on-plate GMAW of Mg alloys that severe spatter can be eliminated by using controlled short circuiting (CSC), and severe hydrogen porosity can be eliminated by removing Mg(OH)2. The present study aimed at actual butt and lap welding of Mg alloys by CSC-GMAW and susceptibility of Mg alloys to weld-edge cracking using the circular-patch welding test. Sound welds were made without spatter and hydrogen porosity butt and lap welding of AZ 31 Mg using CSC-GMAW , with butt welds approaching 100% of the base-metal strength. However, three new significant issues were found to occur easily and degrade the weld quality significantly: 1. formation of oxide films inside butt welds, 2. formation of high crowns on butt welds, and 3. formation of fingers from lap welds. The mechanisms of their formation were established, and the methods for their elimination or reduction were demonstrated. Circular-patch welds were made on most widely used Mg casting alloy AZ91, the most widely used Mg wrought alloy AZ31 with three different Mg filler wires AZ31, AZ61 and AZ92. The susceptibility to cracking along the weld edge was predicted and compared against the experimental results. Such a prediction has not been made for welds of Mg alloys before.

  12. Remote reactor repair: GTA (gas tungsten Arc) weld cracking caused by entrapped helium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanne, Jr, W R

    1988-01-01

    A repair patch was welded to the wall of a nuclear reactor tank using remotely controlled thirty-foot long robot arms. Further repair was halted when gas tungsten arc (GTA) welds joining type 304L stainless steel patches to the 304 stainless steel wall developed toe cracks in the heat-affected zone (HAZ). The role of helium in cracking was investigated using material with entrapped helium from tritium decay. As a result of this investigation, and of an extensive array of diagnostic tests performed on reactor tank wall material, helium embrittlement was shown to be the cause of the toe cracks.

  13. In vivo laser assisted end-to-end anastomosis with ICG-infused chitosan patches

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Esposito, Giuseppe; Scerrati, Alba; Albanese, Alessio; Puca, Alfredo; Maira, Giulio; Rossi, Giacomo; Pini, Roberto

    2011-07-01

    Laser assisted vascular repair is a new optimized technique based on the use of ICG-infused chitosan patch to close a vessel wound, with or even without few supporting single stitches. We present an in vivo experimental study on an innovative end-to-end laser assisted vascular anastomotic (LAVA) technique, performed with the application of ICGinfused chitosan patches. The photostability and the mechanical properties of ICG-infused chitosan films were preliminary measured. The in vivo study was performed in 10 New Zealand rabbits. After anesthesia, a 3-cm segment of the right common carotid artery was exposed, thus clamped proximally and distally. The artery was then interrupted by means of a full thickness cut. Three single microsutures were used to approximate the two vessel edges. The ICG-infused chitosan patch was rolled all over the anastomotic site and welded by the use of a diode laser emitting at 810 nm and equipped with a 300 μm diameter optical fiber. Welding was obtained by delivering single laser spots to induce local patch/tissue adhesion. The result was an immediate closure of the anastomosis, with no bleeding at clamps release. Thus animals underwent different follow-up periods, in order to evaluate the welded vessels over time. At follow-up examinations, all the anastomoses were patent and no bleeding signs were documented. Samples of welded vessels underwent histological examinations. Results showed that this technique offer several advantages over conventional suturing methods: simplification of the surgical procedure, shortening of the operative time, better re-endothelization and optimal vascular healing process.

  14. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  15. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  16. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  17. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  18. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  19. New In-Field Composite Repair Techniques for Transmission or Distribution Pipelines

    DOT National Transportation Integrated Search

    2009-05-18

    In-field repair of a damaged pipeline must be performed safely, efficiently, rapidly and reliably. Reinforcement of damaged pipelines is typically accomplished by welding a repair patch and then recoating the repaired area. The welded full-encircleme...

  20. In vivo experimental study on laser welded ICG-loaded chitosan patches for vessel repair

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Esposito, Giuseppe; Albanese, Alessio; Puca, Alfredo; Maira, Giulio; Rossi, Giacomo; Pini, Roberto

    2011-03-01

    Laser welding of microvessels provides several advantages over conventional suturing techniques: surgical times reduction, vascular healing process improvement, tissue damage reduction. We present the first application of biopolymeric patches in an in vivo laser assisted procedure for vessel repair. The study was performed in 20 New Zealand rabbits. After anesthesia, a 3-cm segment of the right common carotid artery was exposed and clamped proximally and distally. A linear lesion 3 mm in length was carried out. We used a diode laser emitting at 810 nm and equipped with a 300 μm diameter optical fiber. To close the cut, ICG-loaded chitosan films were prepared: chitosan is characterized by biodegradability, biocompatibility, antimicrobial, haemostatic and wound healing-promoting activity. ICG is an organic chromophore commonly used in the laser welding procedures to mediate the photothermal conversion at the basis of the welding effect. The membranes were used to wrap the whole length of the cut, and then they were welded in the correct position by delivering single laser spots to induce local patch/tissue adhesion. The result is an immediate closure of the wound, with no bleeding at clamps release. The animals were observed during follow-up and sacrificed after 2, 7, 30 and 90 days. All the repaired vessels were patent, no bleeding signs were documented. The carotid samples underwent histological examinations. The advantages of the proposed technique are: simplification of the surgical procedure and shortening of the operative time; good strength of the vessel repair; decreased foreign-body reaction, reduced inflammatory response and improved vascular healing process.

  1. Laser welding of chitosan-GNRs films for the closure of a capsulorhexis

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Ratto, Fulvio; Menabuoni, Luca; Lenzetti, Ivo; Pini, Roberto

    2011-03-01

    In this work we present the first attempt to close the anterior lens capsule bag by the use of chitosan patches, where Gold Nanorods (GNRs) are embedded. GNRs exhibit intense localized plasmon resonances at optical frequencies in the near infrared (NIR): upon excitation with a NIR laser, a strong photothermal effect is produced, which can be exploited to develop minimally invasive therapies. Here we use the chitosan-GNRs films as a novel NIR sensitive nanocomposite for the photothermal conversion of NIR laser light during surgical interventions of tissue welding. Chitosan is an attractive biomaterial due to its biodegradability, biocompatibility, antimicrobial and wound healing-promoting activity. Colloidal GNRs were embedded in chitosan based, highly stabilized, flexible and easy-to-handle films, which were stored in water until the time of surgery. In these preliminary tests, a capsulorhexis was performed in freshly enucleated porcine eyes. The lens was aspired, then the patch was put onto the capsule bag and welded: a diode laser (810 nm) was used to deliver single spots (200 μm core diameter optical fiber) of local capsule/patch adhesion. Then the bag was refilled with silicon oil. The result is an immediate closure of the capsular tissue, with high mechanical strength. The laser welded chitosan- GNRs films are an innovative and highly stable solution to be exploited for the treatment of capsular breaks and for the implementation of a lens refilling procedure.

  2. Helical comb magnetostrictive patch transducers for inspecting spiral welded pipes using flexural guided waves.

    PubMed

    Zhang, Xiaowei; Tang, Zhifeng; Lv, Fuzai; Pan, Xiaohong

    2017-02-01

    A wavefront analysis indicates that a flexural wave propagates at a helix angle with respect to the pipe axis. The expression for calculation of the helix angle for each flexural mode is given, and the helix angle dispersion curves for flexural modes are calculated. According to the new understanding of flexural guided waves, a helical comb magnetostrictive patch transducer (HCMPT) is proposed for selectively exciting a single predominant flexural torsional guided wave in a pipe and inspecting spiral welded pipes using flexural waves. A HCMPT contains a pre-magnetized magnetostrictive patch that is helically coupled with the outer surface of a pipe, and a novel compound comb coil that is wrapped around the helical magnetostrictive patch. The proposed wideband HCMPT possesses the direction control ability. A verification experiment indicates that flexural torsional mode T(3,1) at center frequency f=64kHz is effectively actuated by a HCMPT with 13-degree helix angle. Flexural torsional modes T(N,1) with circumferential order N equals 1-5 are selected to inspect a seamless steel pipe, artificial defects are effectively detected by the proposed HCMPT. A 20-degree HCMPT is adopted to inspect a spiral welded pipe, an artificial notch with cross section loss CSL=2.7% is effectively detected by using flexural waves. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Hot-cracking studies of Inconel 718 weld- heat-affected zones

    NASA Technical Reports Server (NTRS)

    Thompson, E. G.

    1969-01-01

    Hot ductility tests, gas-tungsten-arc fillerless fusion tests, and circle patch-weld-restraint tests were conducted on Inconel 718 to better understand and correlate the weldability /resistance to hot cracking/ of the alloy. A correlation of the test results with composition, heat-treat condition, grain size, and microstructure was made.

  4. Finite Element and Analytical Analysis of Cracks in Thick Stiffened Plates Repaired with a Single Sided Composite Patch

    DTIC Science & Technology

    2014-06-01

    DC,Tech. Rep. CG-D-05–00, 2000. [16] S. Kou, Welding Metallurgy , 2nd edition, Hoboken: Wiley Interscience, 2003. [17] C. Poe, “Stress intensity...continuous aluminum superstructure welded to the deck. The shape of the superstructure created numerous stress concentration areas. Of the greatest concern...study as it will help provide a conservative estimate. In marine applications almost all stiffening members are attached by welding . Unlike a

  5. Laser Overlap Welding of Zinc-coated Steel on Aluminum Alloy

    NASA Astrophysics Data System (ADS)

    Kashani, Hamed Tasalloti; Kah, Paul; Martikainen, Jukka

    Local reinforcement of aluminum with laser welded patches of zinc-coated steel can effectively contribute to crashworthiness, durability and weight reduction of car body. However, the weld between Zn-coated steel and aluminum is commonly susceptible to defects such as spatter, cavity and crack. The vaporization of Zn is commonly known as the main source of instability in the weld pool and cavity formation, especially in a lap joint configuration. Cracks are mainly due to the brittle intermetallic compounds growing at the weld interface of aluminum and steel. This study provides a review on the main metallurgical and mechanical concerns regarding laser overlap welding of Zn-coated steel on Al-alloy and the methods used by researchers to avoid the weld defects related to the vaporization of Zn and the poor metallurgical compatibility between steel and aluminum.

  6. Welding and Weldability of AZ31B by Gas Tungsten Arc and Laser Beam Welding Processes

    NASA Astrophysics Data System (ADS)

    Lathabai, S.; Barton, K. J.; Harris, D.; Lloyd, P. G.; Viano, D. M.; McLean, A.

    Welding will play an important role in the fabrication of modular lightweight structures based on magnesium alloy die castings, extrusion profiles and wrought products. Minimisation of rejection rates during fabrication requires that satisfactory weldability be established for a particular combination of materials and welding procedures. In this paper, we present the results of a study to quantify the weldability of wrought alloy AZ31B by gas tungsten arc (GTA) and laser beam (LB) welding processes. The susceptibility to weld metal solidification cracking was evaluated using the Circular Patch weldability test. Operating windows of welding parameters for crack-free and porosity-free GTA and LB welding were identified, based on which welding procedures were developed for sheet and plate AZ31B. The microstructure and mechanical properties of welded test plates were assessed, leading to a better understanding of microstructurat development and structure-property relationships in GTA and LB weldments in AZ31B.

  7. Automatic Detection of Welding Defects using Deep Neural Network

    NASA Astrophysics Data System (ADS)

    Hou, Wenhui; Wei, Ye; Guo, Jie; Jin, Yi; Zhu, Chang'an

    2018-01-01

    In this paper, we propose an automatic detection schema including three stages for weld defects in x-ray images. Firstly, the preprocessing procedure for the image is implemented to locate the weld region; Then a classification model which is trained and tested by the patches cropped from x-ray images is constructed based on deep neural network. And this model can learn the intrinsic feature of images without extra calculation; Finally, the sliding-window approach is utilized to detect the whole images based on the trained model. In order to evaluate the performance of the model, we carry out several experiments. The results demonstrate that the classification model we proposed is effective in the detection of welded joints quality.

  8. Investigation on laser-assisted tissue repair with NIR millisecond-long light pulses and Indocyanine Green-biopolymeric patches

    NASA Astrophysics Data System (ADS)

    Matteini, Paolo; Banchelli, Martina; Cottat, Maximilien; Osticioli, Iacopo; de Angelis, Marella; Rossi, Francesca; Pini, Roberto

    2016-03-01

    In previous works a minimally invasive laser-assisted technique for vascular repair was presented. The technique rests on the photothermal adhesion of a biocompatible and bioresorbable patch containing Indocyanine Green that is brought into contact with the site to be repaired. Afterward the use of NIR millisecond-long light pulses generates a strong welding effect between the patch and the underlying tissue and in turn the repair of the wound. This technique was shown to be effective in animal model and provides several advantages over conventional suturing methods. Here we investigate and discuss the optical stability of the ICG-biopolymeric patches and the photothermal effects induced to the irradiated tissue.

  9. Thermal and molecular investigation of laser tissue welding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Small, W., IV

    1998-06-01

    Despite the growing number of successful animal and human trials, the exact mechanisms of laser tissue welding remain unknown. Furthermore, the effects of laser heating on tissue on the molecular scale are not fully understood. To address these issues, a multi-front attack oil both extrinsic (solder/patch mediated) and intrinsic (laser only) tissue welding was launched using two-color infrared thermometry, computer modeling, weld strength assessment, biochemical assays, and vibrational spectroscopy. The coupling of experimentally measured surface temperatures with the predictive numerical simulations provided insight into the sub-surface dynamics of the laser tissue welding process. Quantification of the acute strength of themore » welds following the welding procedure enabled comparison among trials during an experiment, with previous experiments, and with other studies in the literature. The acute weld integrity also provided an indication of tile probability of long-term success. Molecular effects induced In the tissue by laser irradiation were investigated by measuring tile concentrations of specific collagen covalent crosslinks and characterizing the Fourier-Transform infrared (FTIR) spectra before and after the laser exposure.« less

  10. Thermal and molecular investigation of laser tissue welding

    NASA Astrophysics Data System (ADS)

    Small, Ward, IV

    Despite the growing number of successful animal and human trials, the exact mechanisms of laser tissue welding remain unknown. Furthermore, the effects of laser heating on tissue on the molecular scale are not fully understood. To address these issues, a multi-front attack on both extrinsic (solder/patch mediated) and intrinsic (laser only) tissue welding was launched using two-color infrared thermometry, computer modeling, weld strength assessment, biochemical assays, and vibrational spectroscopy. The coupling of experimentally measured surface temperatures with the predictive numerical simulations provided insight into the sub surface dynamics of the laser tissue welding process. Quantification of the acute strength of the welds following the welding procedure enabled comparison among trials during an experiment, with previous experiments, and with other studies in the literature. The acute weld integrity also provided an indication of the probability of long-term success. Molecular effects induced in the tissue by laser irradiation were investigated by measuring the concentrations of specific collagen covalent crosslinks and measuring the infrared absorption spectra before and after the laser exposure. This investigation yielded results pertaining to both the methods and mechanisms of laser tissue welding. The combination of two-color infrared thermometry to obtain accurate surface temperatures free from emissivity bias and computer modeling illustrated the importance of including evaporation in the simulations, which effectively serves as an inherent cooling mechanism during laser irradiation. Moreover, the hydration state predicted by the model was useful in assessing the role of electrostatic versus covalent bonding in the fusion. These tools also helped elicit differences between dye- enhanced liquid solders and solid-matrix patches in laser-assisted tissue welding, demonstrating the significance of repeatable energy delivery. Surprisingly, covalent bonds between collagen molecules (crosslinks) were formed in tissue when exposed to the commonly used absorbing chromophore indocyanine green (ICG) prior to laser irradiation, which restored the crosslink concentrations to their native levels. Crosslinks were either created or destroyed during exposure to green laser light without any extrinsic materials or chromophores, which may impact the acute and long-term strength and stability of laser welded tissues. Infrared spectroscopy revealed changes in collagen conformation (molecular structure) induced by laser heating as a function of temperature, elucidating the dynamics of the denaturation process.

  11. Plating Patches On Heat-Exchanger Jackets

    NASA Technical Reports Server (NTRS)

    Loureiro, Henry; Kubik, Frank

    1989-01-01

    Permanent repairs made without welding. Technique used to repair nickel-alloy nozzle jacket of Space Shuttle main engine. Applicable to other metal heat-exchanger jackets with similar configurations. Does not require welding, brazing, soldering, or other operations involving high temperatures and consequent damage to surrounding areas. Portion of jacket around damaged area removed by grinding and polishing out to edges adjacent to tube/jacket braze bonds. Spaces between tubes filled with wax preventing contamination of spaces during subsequent plating.

  12. Laser welding versus suturing in tunica vaginalis and venous patch graft corporoplasty.

    PubMed

    Kirsch, A J; Chang, D T; Miller, M I; Connor, J P; Hensle, T W; Shabsigh, R

    1995-08-01

    Congenital penile curvature may result from corporeal disproportion in nearly 40% of cases, while in adults scarring of the corporeal bodies or periurethral fibrosis accounts for the majority of cases. Some surgeons advocate lengthening the fibrosed corporeal bodies by excising tunica albuginea and grafting such defects to straighten the penis. Tunica vaginalis, dermis, dorsal vein and lyophilized dura have been used for this purpose. Traditionally, these graft biomaterials have been sutured to the tunica albuginea. We assessed the feasibility, short-term safety and efficacy of diode laser tissue welding using albumin based solder and indocyanine green dye to perform patch graft corporoplasty in the dog. Ten animals were subjected to bilateral transverse excision of 1 x 2 cm. sections of tunica albuginea. Corporoplasty was performed using grafts composed of saphenous vein (5) or tunica vaginalis (5). Microsurgical repair with 7-zero polydioxanone suture (10) was compared to contralateral laser welded repair (10) by recording operative time, initial and short-term bursting pressures (mean plus or minus standard deviation) and histological analysis. Operative time on the laser side (9.8 +/- 2.3 minutes) was significantly shorter (p < 0.05) than on the suture side (17.1 +/- 5.1 minutes). Leak pressures, initially (laser 105.7 +/- 23.8 mm. Hg versus suture 35.3 +/- 8.0 mm. Hg), at 3 to 5 days (greater than 333.3 +/- 62.4 mm. Hg versus 136.6 +/- 39.4 mm. Hg) and at 7 to 10 days (greater than 397.8 +/- 39.8 mm. Hg versus 191.5 +/- 46.4 mm. Hg) were higher (p < 0.05) in the laser side compared to controls. Graft failure (necrosis) occurred in 3 repairs (2 laser on day 4 and 1 suture on day 10). Viable tissue with minimal differences in foreign body reaction between groups was observed in the remaining grafts. We conclude that laser welded patch graft corporoplasty using tunica vaginalis or vein is easy to perform, and provides excellent initial and short-term leak pressures. The use of laser welding in conjunction with suturing may be beneficial in corporoplasty for congenital or acquired penile curvature.

  13. Sutureless closure of scleral wounds in animal models by the use of laser welded biocompatible patches

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Menabuoni, Luca; Lenzetti, Ivo; Pini, Roberto

    2011-03-01

    The common procedures used to seal the scleral or conjunctival injuries are based on the traditional suturing techniques, that may induce foreign body reaction during the follow up, with subsequent inflammation and distress for the patient. In this work we present an experimental study on the laser welding of biocompatible patches onto ocular tissues, for the closure of surgical or trauma wounds. The study was performed ex vivo in animal models (porcine eyes). A penetrating perforation of the ocular tissue was performed with a surgical knife. The wound walls were approximated, and a biocompatible patch was put onto the outer surface of the tissue, in order to completely cover the wound as a plaster. The patches were prepared with a biocompatible and biodegradable polymer, showing high mechanical strength, good elasticity, high permeability for vapour and gases and rather low biodegradation. During preparation, Indocyanine Green (ICG) was included in the biopolymeric matrix, so that the films presented high absorption at 810 nm. Effective adhesion of the membranes to the ocular tissues was obtained by using diode laser light emitted from an 810 nm diode laser and delivered by means of a 300 μm core diameter optical fiber, to produce spots of local film/tissue adhesion, due to the photothermal effect at the interface. The result is an immediate closure of the wound, thus reducing post-operative complications due to inflammation.

  14. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

    PubMed

    Ionita, Ciprian N; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M; Hoffmann, K R; Bednarek, D R; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.

  15. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study

    PubMed Central

    Ionita, Ciprian N.; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M.; Hoffmann, K R.; Bednarek, D. R.; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage. PMID:19763252

  16. Handbook for Repairing Nonconventional Roofing Systems

    DTIC Science & Technology

    1988-12-01

    membrane. 61 PIMB (solvent) Figure 71. Apply welding solvent to the PIB patch. Figure 72. Work the solvent Into the P113 patch. Pila 62 (solvent) Figure 73...when exposed to flame but will not burn nor support combustion . PVC repair techniques are basically the same as for a new application of a PVC fully...granules (if desired) before the final coat dries. 83 PUF F4gue 102. Remove the damaged material and bevel the s! des of the hole. 4󈧵, Figure 103. Trim th

  17. Single-Layer, All-Metal Patch Antenna Element with Wide Bandwidth

    NASA Technical Reports Server (NTRS)

    Chamberlain, Neil F.; Hodges, Richard E.; Zawardzki, Mark S.

    2012-01-01

    It is known that the impedance at the center of a patch antenna element is a short circuit, implying that a wire or post can be connected from the patch to the groundplane at this point without impacting radiation performance. In principle, this central post can be used to support the patch element, thus eliminating the need for dielectric. In spaceborne applications, this approach is problematic because a patch element supported by a single, thin post is highly susceptible to acoustic loads during launch. The technology reported here uses a large-diameter center post as its supporting structure. The supporting structure allows for the fabrication of a sufficiently rigid antenna element that can survive launch loads. The post may be either hollow or solid, depending on fabrication approach and/or mass constraints. The patch antenna element and support post are envisioned as being fabricated (milled) from a single piece of aluminum or other metal. Alternately, the patch plate and support column can be fabricated separately and then joined using fasteners, adhesive, or welding. Casting and electroforming are also viable techniques for manufacturing the metal patch part(s). The patch structure is then either bonded or fastened to the supporting groundplane. Arrays of patch elements can be fabricated by attaching several structures to a common groundplane/support structure.

  18. Rationale, scope, and 20-year experience of vascular surgical training with lifelike pulsatile flow models.

    PubMed

    Eckstein, Hans-Henning; Schmidli, Jürg; Schumacher, Hardy; Gürke, Lorenz; Klemm, Klaus; Duschek, Nikolaus; Meile, Toni; Assadian, Afshin

    2013-05-01

    Vascular surgical training currently has to cope with various challenges, including restrictions on work hours, significant reduction of open surgical training cases in many countries, an increasing diversity of open and endovascular procedures, and distinct expectations by trainees. Even more important, patients and the public no longer accept a "learning by doing" training philosophy that leaves the learning curve on the patient's side. The Vascular International (VI) Foundation and School aims to overcome these obstacles by training conventional vascular and endovascular techniques before they are applied on patients. To achieve largely realistic training conditions, lifelike pulsatile models with exchangeable synthetic arterial inlays were created to practice carotid endarterectomy and patch plasty, open abdominal aortic aneurysm surgery, and peripheral bypass surgery, as well as for endovascular procedures, including endovascular aneurysm repair, thoracic endovascular aortic repair, peripheral balloon dilatation, and stenting. All models are equipped with a small pressure pump inside to create pulsatile flow conditions with variable peak pressures of ~90 mm Hg. The VI course schedule consists of a series of 2-hour modules teaching different open or endovascular procedures step-by-step in a standardized fashion. Trainees practice in pairs with continuous supervision and intensive advice provided by highly experienced vascular surgical trainers (trainer-to-trainee ratio is 1:4). Several evaluations of these courses show that tutor-assisted training on lifelike models in an educational-centered and motivated environment is associated with a significant increase of general and specific vascular surgical technical competence within a short period of time. Future studies should evaluate whether these benefits positively influence the future learning curve of vascular surgical trainees and clarify to what extent sophisticated models are useful to assess the level of technical skills of vascular surgical residents at national or international board examinations. This article gives an overview of our experiences of >20 years of practical training of beginners and advanced vascular surgeons using lifelike pulsatile vascular surgical training models. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  19. Repairing Hard-to-Reach Cracks in Heat-Exchanger Tubes

    NASA Technical Reports Server (NTRS)

    Mills, R. C., Sr.; Duesberg, J.

    1986-01-01

    Inaccessible leaks repaired from accessible side of tube. Fish-Mouth insert placed in cut in leaky heat-exchanger tube. Insert welded or brazed to tube, and remaining open area of cut patched. Method developed for repairing leaks in nozzle coolant tubes of Space Shuttle main engine. Method also used on other types of tubular heat exchangers.

  20. Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology.

    PubMed

    Dohatcu, A; Ionita, C N; Paciorek, A; Bednarek, D R; Hoffmann, K R; Rudin, S

    2008-01-01

    In this study, we compare the results obtained from Time-Density Curve (TDC) analysis of angiographic imaging sequences with histological evaluation for a rabbit aneurysm model treated with standard stents and new asymmetric vascular stents (AVS) placed by image-guided endovascular deployment. AVSs are stents having a low-porosity patch region designed to cover the aneurysm neck and occlude blood flow inside. To evaluate the AVSs, rabbits with elastase-induced aneurysm models (n=20) were divided into three groups: the first (n=10) was treated with an AVS, the second (n=5) with a non-patch standard coronary stent, and third was untreated as a control (n=5). We used TDC analysis to measure how much contrast media entered the aneurysm before and after treatment. TDCs track contrast-media-density changes as a function of time over the region of interest in x-ray DSA cine-sequences. After 28 days, the animals were sacrificed and the explanted specimens were histologically evaluated. The first group showed an average reduction of contrast flow into the aneurysm of 95% after treatment with an AVS with fully developed thrombus at 28 days follow-up. The rabbits treated with standard stents showed an increase in TDC residency time after treatment and partial-thrombogenesis. The untreated control aneurysms displayed no reduction in flow and were still patent at follow-up. The quantitative TDC analysis findings were confirmed by histological evaluation suggesting that the new AVS has great potential as a definitive treatment for cerebro-vascular aneurysms and that angiographic TDC analysis can provide in-vivo verification.

  1. Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology

    PubMed Central

    Dohatcu, A.; Ionita, C. N.; Paciorek, A.; Bednarek, D. R.; Hoffmann, K. R.; Rudin, S.

    2008-01-01

    In this study, we compare the results obtained from Time-Density Curve (TDC) analysis of angiographic imaging sequences with histological evaluation for a rabbit aneurysm model treated with standard stents and new asymmetric vascular stents (AVS) placed by image-guided endovascular deployment. AVSs are stents having a low-porosity patch region designed to cover the aneurysm neck and occlude blood flow inside. To evaluate the AVSs, rabbits with elastase-induced aneurysm models (n=20) were divided into three groups: the first (n=10) was treated with an AVS, the second (n=5) with a non-patch standard coronary stent, and third was untreated as a control (n=5). We used TDC analysis to measure how much contrast media entered the aneurysm before and after treatment. TDCs track contrast-media-density changes as a function of time over the region of interest in x-ray DSA cine-sequences. After 28 days, the animals were sacrificed and the explanted specimens were histologically evaluated. The first group showed an average reduction of contrast flow into the aneurysm of 95% after treatment with an AVS with fully developed thrombus at 28 days follow-up. The rabbits treated with standard stents showed an increase in TDC residency time after treatment and partial-thrombogenesis. The untreated control aneurysms displayed no reduction in flow and were still patent at follow-up. The quantitative TDC analysis findings were confirmed by histological evaluation suggesting that the new AVS has great potential as a definitive treatment for cerebro-vascular aneurysms and that angiographic TDC analysis can provide in-vivo verification. PMID:18958295

  2. Non-ischemic cerebral enhancing lesions secondary to endovascular aneurysm therapy: nickel allergy or foreign body reaction? Case series and review of the literature.

    PubMed

    Shotar, Eimad; Law-Ye, Bruno; Baronnet-Chauvet, Flore; Zeidan, Sinead; Psimaras, Dimitri; Bielle, Franck; Pecquet, Catherine; Navarro, Soledad; Rosso, Charlotte; Cohen, Fleur; Chiras, Jacques; Di Maria, Federico; Sourour, Nader; Clarençon, Frédéric

    2016-09-01

    Delayed onset of non-ischemic cerebral enhancing (NICE) lesions is a rare complication of intracranial aneurysms' endovascular therapy (EVT). The purpose of this study is to report this rare complication and its potential pathophysiology in a single-center case series and review the relevant literature. After retrospective review of all patients managed by EVT at our institution from January 1, 2012 to December 31, 2014, 2 out of 374 patients (0.5 %) with such a complication were identified. Skin patch testing was performed with all endovascular devices used in the two patients and with the European baseline series, including nickel. All previously published cases in the English literature were reviewed based on exhaustive PubMed and Embase research. Patient no. 1 developed NICE lesions 1 month after balloon-assisted coiling of a ruptured anterior communicating artery aneurysm. Patient no. 2 developed NICE lesions 12 months (the longest delay reported to date for such a complication) after the treatment of a right carotid-ophthalmic aneurysm by loose coiling and flow diversion. Patient no. 2 demonstrated nickel skin reactivity, but none of the two patients presented allergic reaction to the devices used during interventions. Based on our observations and review of the literature, we hypothesize that delayed non-ischemic cerebral enhancing lesions after EVT are more likely related to foreign body emboli rather than nickel allergy. The two presented cases demonstrate the potential for recurrence and prolonged fluctuation of NICE lesions, warranting long-term follow-up for all patients presenting this complication.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cotroneo, Antonio Raffaele; Iezzi, Roberto, E-mail: iezzir@virgilio.i

    This study was designed to report our experience with 'cutting' balloon angioplasty (CBA) for the treatment of short femoral bifurcation arterial stenosis. Between March 2005 and September 2007, 18 consecutive patients who were high-risk for surgery with critical limb ischemia or severe lifestyle-limiting claudication underwent 'cutting' balloon angioplasty (4-6 mm diameter/15-20-mm length) for the treatment of 27 focal (<3 cm) severe fibro-calcified stenosis of the common femoral artery (n = 14) and/or the proximal part of the superficial femoral artery (n = 6) or profunda femoris (n = 7). Baseline patient demographic data, pre- and post-procedural patient clinical data, andmore » procedural results were recorded. Follow-up consisted of clinical check-up and color duplex ultrasonography (CDU) examination 1, 3, 6, 12, and 18 months after the procedure. All endovascular treatments were successfully performed with clinical success obtained for all patients. No complications occurred during all treatments and no patient required surgical conversion or placement of a stent because of recoil, dissection, or arterial tears. No acute vessel closure was registered. During a mean follow-up of 9.4 (range, 6-18) months, endovascular treatment (CBA) was performed for restenosis/occlusion of seven lesions (25.9%) in four patients, whereas surgical treatment (endarterectomy with patch) for restenosis/occlusion of three lesions (11.1%) was performed in two patients with a consequent reintervention rate of 37%. Primary and secondary patency rates were 84.6 and 88.4% at 6 months and 57.9 and 79.6% at 12 months, respectively. No major limb amputation was performed, with a 12-month limb salvage rate of 88.9%. CBA seems to be a valuable tool for the endovascular treatment of focal femoral bifurcation stenotic lesions for patients who are poor candidates for surgery.« less

  4. Evaluation of Microstructure, Mechanical Properties and Corrosion Resistance of Friction Stir-Welded Aluminum and Magnesium Dissimilar Alloys

    NASA Astrophysics Data System (ADS)

    Verma, Jagesvar; Taiwade, Ravindra V.; Sapate, Sanjay G.; Patil, Awanikumar P.; Dhoble, Ashwinkumar S.

    2017-10-01

    Microstructure, mechanical properties and corrosion resistance of dissimilar friction stir-welded aluminum and magnesium alloys were investigated by applying three different rotational speeds at two different travel speeds. Sound joints were obtained in all the conditions. The microstructure was examined by an optical and scanning electron microscope, whereas localized chemical information was studied by energy-dispersive spectroscopy. Stir zone microstructure showed mixed bands of Al and Mg with coarse and fine equiaxed grains. Grain size of stir zone reduced compared to base metals, indicated by dynamic recrystallization. More Al patches were observed in the stir zone as rotational speed increased. X-ray diffraction showed the presence of intermetallics in the stir zone. Higher tensile strength and hardness were obtained at a high rotational speed corresponding to low travel speed. Tensile fractured surface indicated brittle nature of joints. Dissimilar friction stir weld joints showed different behaviors in different corrosive environments, and better corrosion resistance was observed at a high rotational speed corresponding to low travel speed (FW3) in a sulfuric and chloride environments. Increasing travel speed did not significantly affect on microstructure, mechanical properties and corrosion resistance as much as the rotational speed.

  5. Detection of damage in welded structure using experimental modal data

    NASA Astrophysics Data System (ADS)

    Abu Husain, N.; Ouyang, H.

    2011-07-01

    A typical automotive structure could contain thousands of spot weld joints that contribute significantly to the vehicle's structural stiffness and dynamic characteristics. However, some of these joints may be imperfect or even absent during the manufacturing process and they are also highly susceptible to damage due to operational and environmental conditions during the vehicle lifetime. Therefore, early detection and estimation of damage are important so necessary actions can be taken to avoid further problems. Changes in physical parameters due to existence of damage in a structure often leads to alteration of vibration modes; thus demonstrating the dependency between the vibration characteristics and the physical properties of structures. A sensitivity-based model updating method, performed using a combination of MATLAB and NASTRAN, has been selected for the purpose of this work. The updating procedure is regarded as parameter identification which aims to bring the numerical prediction to be as closely as possible to the measured natural frequencies and mode shapes data of the damaged structure in order to identify the damage parameters (characterised by the reductions in the Young's modulus of the weld patches to indicate the loss of material/stiffness at the damage region).

  6. Robert H. Goddard and His Liquid-Gasoline Rocket

    NASA Technical Reports Server (NTRS)

    1926-01-01

    Dr. Goddard's 1926 rocket configuration. Dr. Goddard's liquid oxygen-gasoline rocket was fired on March 16, 1926, at Auburn, Massachusetts. It flew for only 2.5 seconds, climbed 41 feet, and landed 184 feet away in a cabbage patch. From 1930 to 1941, Dr. Goddard made substantial progress in the development of progressively larger rockets, which attained altitudes of 2400 meters, and refined his equipment for guidance and control, his techniques of welding, and his insulation, pumps, and other associated equipment. In many respects, Dr. Goddard laid the essential foundations of practical rocket technology

  7. Early Rockets

    NASA Image and Video Library

    1926-03-16

    Dr. Goddard's 1926 rocket configuration. Dr. Goddard's liquid oxygen-gasoline rocket was fired on March 16, 1926, at Auburn, Massachusetts. It flew for only 2.5 seconds, climbed 41 feet, and landed 184 feet away in a cabbage patch. From 1930 to 1941, Dr. Goddard made substantial progress in the development of progressively larger rockets, which attained altitudes of 2400 meters, and refined his equipment for guidance and control, his techniques of welding, and his insulation, pumps, and other associated equipment. In many respects, Dr. Goddard laid the essential foundations of practical rocket technology

  8. Early Rockets

    NASA Image and Video Library

    1926-03-16

    Dr. Robert H. Goddard and liquid oxygen-gasoline rocket in the frame from which it was fired on March 16, 1926, at Auburn, Mass. It flew for only 2.5 seconds, climbed 41 feet, and landed 184 feet away in a cabbage patch. From 1930 to 1941, Dr. Goddard made substantial progress in the development of progressively larger rockets, which attained altitudes of 2400 meters, and refined his equipment for guidance and control, his techniques of welding, and his insulation, pumps, and other associated equipment. In many respects, Dr. Goddard laid the essential foundations of practical rocket technology

  9. Hot cracking during welding and casting

    NASA Astrophysics Data System (ADS)

    Cao, Guoping

    Aluminum welds are susceptible to liquation cracking in the partially melted zone (PMZ). Using the multicomponent Scheil model, curves of temperature vs. fraction solid (T-fS) during solidification were calculated for the PMZ and weld metals (WMs). These curves were used to predict the crack susceptibility by checking if the harmful condition of WM fS > PMZ fS exists during PMZ solidification and reduce the susceptibility by minimizing this condition. This approach was tested against full-penetration welds of alloys 7075 and 2024 and it can be used to guide the selection or development of filler metals. Liquation cracking in the PMZ in welds of Al-Si cast alloys was also investigated. The crack susceptibility was evaluated by circular-patch test, and full-penetration welds made with filler metals 1100, 4043, 4047 and 5356. Liquation cracking was significant with filler metals 1100 and 5356 but slight with filler metals 4043 and 4047. In all welds, liquation cracks were completely backfilled, instead of open as in full-penetration welds of wrought alloys 2219 and 6061. The T-fS curves showed that alloy A357 has a much higher fraction liquid for backfilling before PMZ solidification was essentially over. Hot tearing in Mg-xAl-yCa alloys was studied by constrained rod casting (CRC) in a steel mold. The hot tearing susceptibility decreased significantly with increasing Ca content (y) but did not change much with the Al content (x). An instrumented CRC with a steel mold was developed to detect the onset of hot tearing. The secondary phases, eutectic content, solidification path, and freezing range were examined. Hot tearing in Mg-Al-Sr alloys was also studied by CRC in a steel mold. With Mg-(4,6,8)Al-1.5Sr alloys, the hot tearing susceptibility decreased significantly with increasing Al content. With Mg-(4,6,8)Al-3Sr alloys, the trend was similar but not as significant. At the same Al content, the hot tearing susceptibility decreased significantly with increasing Sr content. Instrumented CRC with a steel mold was also used to test hot tearing of Mg-Al-Sr alloys. Cracking occurred at a higher temperature in alloys most susceptible to cracking than in alloys least susceptible.

  10. [Cockett's syndrome, May-Thurner syndrome, or iliac vein compression syndrome].

    PubMed

    Gil Martín, A R; Carreras Aja, M; Arrieta Ardieta, I; Labayen Azparren, I

    2014-01-01

    Iliac vein compression syndrome (also known as May-Thurner syndrome or Cockett's syndrome) is a rare clinical entity in which the left common iliac vein is compressed when it passes between the right common iliac artery and the spine. The sustained compression and trauma caused by the pulsatile force of the artery on the vein damage the intima and lead to the formation of membranes or bands in the vascular lumen that hinder or obstruct the flow of blood in the vein, favoring thrombus formation. The current treatment strategy of choice is endovascular vein patch angioplasty and stenting with the aim of improving the caliber of the lumen and enabling normal venous drainage. We present two cases of May-Thurner syndrome and review the clinical and CT findings. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  11. Aortic aneurysm repair - endovascular

    MedlinePlus

    EVAR; Endovascular aneurysm repair - aorta; AAA repair - endovascular; Repair - aortic aneurysm - endovascular ... to guide the stent graft up into your aorta, to where the aneurysm is located. Next open ...

  12. [Endovascular surgery in the war].

    PubMed

    Reva, V A; Samokhvalov, I M

    2015-01-01

    Rapid growth of medical technologies has led to implementation of endovascular methods of diagnosis and treatment into rapidly developing battlefield surgery. This work based on analysing all available current publications generalizes the data on using endovascular surgery in combat vascular injury. During the Korean war (1950-1953) American surgeons for the first time performed endovascular balloon occlusion of the aorta - the first intravascular intervention carried out in a zone of combat operations. Half a century thereafter, with the beginning of the war in Afghanistan (2001) and in Iraq (2003) surgeons of central hospitals of the USA Armed Forces began performing delayed endovascular operations to the wounded. The development of technologies, advent of mobile angiographs made it possible to later on implement high-tech endovascular interventions in a zone of combat operations. At first, more often they performed implantation of cava filters, somewhat afterward - angioembolization of damaged accessory vessels, stenting and endovascular repair of major arteries. The first in the theatre of war endovascular prosthetic repair of the thoracic aorta for severe closed injury was performed in 2008. Russian experience of using endovascular surgery in combat injuries is limited to diagnostic angiography and regional intraarterial perfusion. Despite the advent of stationary angiographs in large hospitals of the RF Ministry of Defence in the early 1990s, endovascular operations for combat vascular injury are casuistic. Foreign experience in active implementation of endovascular technologies to treatment of war-time injuries has substantiated feasibility of using intravascular interventions in tertiary care military hospitals. Carrying out basic training courses on endovascular surgery should become an organic part of preparing multimodality general battlefield surgeons rendering care on the theatre of combat operations.

  13. 21 CFR 870.3460 - Endovascular Suturing System.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...

  14. 21 CFR 870.3460 - Endovascular Suturing System.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...

  15. 21 CFR 870.3460 - Endovascular Suturing System.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...

  16. Laser bonding with ICG-infused chitosan patches: preliminary experiences in suine dura mater and vocal folds

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Ratto, Fulvio; Pini, Roberto; Iacoangeli, Maurizio; Giannoni, Luca; Fortuna, Damiano; Di Cicco, Emiliano; Corbara, Sylwia; Dallari, Stefano

    2014-05-01

    Laser bonding is a promising minimally invasive approach, emerging as a valid alternative to conventional suturing techniques. It shows widely demonstrated advantages in wound treatment: immediate closuring effect, minimal inflammatory response and scar formation, reduced healing time. This laser based technique can overcome the difficulties in working through narrow surgical corridors (e.g. the modern "key-hole" surgery as well as the endoscopy setting) or in thin tissues that are impossible to treat with staples and/or stitches. We recently proposed the use of chitosan matrices, stained with conventional chromophores, to be used in laser bonding of vascular tissue. In this work we propose the same procedure to perform laser bonding of vocal folds and dura mater repair. Laser bonding of vocal folds is proposed to avoid the development of adhesions (synechiae), after conventional or CO2 laser surgery. Laser bonding application in neurosurgery is proposed for the treatment of dural defects being the Cerebro Spinal Fluid leaks still a major issue. Vocal folds and dura mater were harvested from 9-months old porks and used in the experimental sessions within 4 hours after sacrifice. In vocal folds treatment, an IdocyanineGreen-infused chitosan patch was applied onto the anterior commissure, while the dura mater was previously incised and then bonded. A diode laser emitting at 810 nm, equipped with a 600 μm diameter optical fiber was used to weld the patch onto the tissue, by delivering single laser spots to induce local patch/tissue adhesion. The result is an immediate adhesion of the patch to the tissue. Standard histology was performed, in order to study the induced photothermal effect at the bonding sites. This preliminary experimental activity shows the advantages of the proposed technique in respect to standard surgery: simplification of the procedure; decreased foreign-body reaction; reduced inflammatory response; reduced operating times and better handling in depth.

  17. Traumatic cervical internal carotid artery pseudoaneurysm in a child refractory to initial endovascular treatment: case report and technical considerations.

    PubMed

    Wang, Arthur; Santarelli, Justin G; Stiefel, Michael F

    2016-12-01

    Optimal management of extracranial carotid artery dissections (eCAD) in pediatric patients is not well documented, and endovascular interventions are rarely reported. A 10-year-old girl sustained multiple systemic injuries in a motor vehicle accident, including an eCAD with pseudoaneurysm. She initially failed both aspirin and endovascular stenting with progressive enlargement of a traumatic cervical carotid pseudoaneurysm and stenosis. Second-stage endovascular stent placement with coiling resulted in successful occlusion of the pseudoaneurysm. At 30-month imaging follow-up, the parent vessel remained patent with no evidence of the pseudoaneurysm. In the setting of poly-trauma, management of eCAD can be complex especially in the pediatric population. There is little data on the endovascular treatment of eCAD in children. Failed endovascular therapies are extremely rare. Our report supports surveillance imaging as repeat endovascular treatment may be necessary.

  18. Virtual reality simulation for the optimization of endovascular procedures: current perspectives.

    PubMed

    Rudarakanchana, Nung; Van Herzeele, Isabelle; Desender, Liesbeth; Cheshire, Nicholas J W

    2015-01-01

    Endovascular technologies are rapidly evolving, often requiring coordination and cooperation between clinicians and technicians from diverse specialties. These multidisciplinary interactions lead to challenges that are reflected in the high rate of errors occurring during endovascular procedures. Endovascular virtual reality (VR) simulation has evolved from simple benchtop devices to full physic simulators with advanced haptics and dynamic imaging and physiological controls. The latest developments in this field include the use of fully immersive simulated hybrid angiosuites to train whole endovascular teams in crisis resource management and novel technologies that enable practitioners to build VR simulations based on patient-specific anatomy. As our understanding of the skills, both technical and nontechnical, required for optimal endovascular performance improves, the requisite tools for objective assessment of these skills are being developed and will further enable the use of VR simulation in the training and assessment of endovascular interventionalists and their entire teams. Simulation training that allows deliberate practice without danger to patients may be key to bridging the gap between new endovascular technology and improved patient outcomes.

  19. Endovascular Thrombolysis Using Monteplase for Non-chronic Deep Venous Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamagami, Takuji, E-mail: yamagami@koto.kpu-m.ac.jp; Yoshimatsu, Rika, E-mail: rika442@koto.kpu-m.ac.jp; Tanaka, Osamu, E-mail: otanaka@koto.kpu-m.ac.jp

    This study was designed to evaluate the usefulness of endovascular thrombolysis using monteplase for deep venous thrombosis (DVT). Between December 2005 and October 2009, at our institution nine endovascular thrombolysis treatments with monteplase were performed for symptomatic DVT in eight patients (6 women, 2 men; mean age, 56 (range, 15-80) years). In all, systemic anticoagulation administered by the peripheral intravenous route with heparin and/or thrombolysis with urokinase followed by anticoagulation with orally administered warfarin had been performed, and subsequently six endovascular treatments without monteplase were administered. However, DVT persisted, and endovascular treatments with monteplase were tried. In six (67%) ofmore » the nine procedures, DVT completely or almost completely disappeared after endovascular thrombolysis with monteplase. Mean dose of monteplase used was 2,170,000 IU. There was only one procedure-related complication. In one patient, just after thrombolysis with monteplase, bleeding at the puncture site and gingival bleeding occurred. Bleeding was stopped by manual astriction only. Endovascular thrombolysis with monteplase may be an effective treatment for DVT, even in cases resistant to traditional systemic anticoagulation and thrombolysis and endovascular procedures without monteplase.« less

  20. Endograft collapse following endovascular repair of traumatic aortic injury.

    PubMed

    Annamalai, Ganesan; Cook, Richard; Martin, Michael

    2011-03-01

    The advent of endovascular treatment of traumatic thoracic aortic injuries offers a valuable, minimally invasive alternative to open surgical repair. However, there are limitations of the current endovascular stent graft technology for this group of patients. After endovascular repair meticulous follow-up is required with a high index of suspicion for potential complications including the lethal complication of endograft collapse.

  1. Surgery insight: advances in endovascular repair of abdominal aortic aneurysms.

    PubMed

    Baril, Donald T; Jacobs, Tikva S; Marin, Michael L

    2007-04-01

    Despite improvements in diagnostic and therapeutic methods and an increased awareness of their clinical significance, abdominal aortic aneurysms (AAAs) continue to be a major source of morbidity and mortality. Endovascular repair of AAAs, initially described in 1990, offers a less-invasive alternative to conventional open repair. The technology and devices used for endovascular repair of AAAs have progressed rapidly and the approach has proven to be safe and effective in short to midterm investigations. Furthermore, several large trials have demonstrated that elective endovascular repair is associated with lower perioperative morbidity and mortality than open repair. The long-term benefits of endovascular repair relative to open repair, however, continue to be studied. In addition to elective repair, the use of endovascular repair for ruptured AAAs has been increasing, and has been shown to be associated with reduced perioperative morbidity and mortality. Advances in endovascular repair of AAAs, including the development of branched and fenestrated grafts and the use of implantable devices to measure aneurysm-sac pressures following stent-graft deployment, have further broadened the application of the technique and have enhanced postoperative monitoring. Despite these advances, endovascular repair of AAAs remains a relatively novel technique, and further long-term data need to be collected.

  2. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), whichmore » was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.« less

  3. Long-term comparison of endovascular and open repair of abdominal aortic aneurysm.

    PubMed

    Lederle, Frank A; Freischlag, Julie A; Kyriakides, Tassos C; Matsumura, Jon S; Padberg, Frank T; Kohler, Ted R; Kougias, Panagiotis; Jean-Claude, Jessie M; Cikrit, Dolores F; Swanson, Kathleen M

    2012-11-22

    Whether elective endovascular repair of abdominal aortic aneurysm reduces long-term morbidity and mortality, as compared with traditional open repair, remains uncertain. We randomly assigned 881 patients with asymptomatic abdominal aortic aneurysms who were candidates for both procedures to either endovascular repair (444) or open repair (437) and followed them for up to 9 years (mean, 5.2). Patients were selected from 42 Veterans Affairs medical centers and were 49 years of age or older at the time of registration. More than 95% of the patients underwent the assigned repair. For the primary outcome of all-cause mortality, 146 deaths occurred in each group (hazard ratio with endovascular repair versus open repair, 0.97; 95% confidence interval [CI], 0.77 to 1.22; P=0.81). The previously reported reduction in perioperative mortality with endovascular repair was sustained at 2 years (hazard ratio, 0.63; 95% CI, 0.40 to 0.98; P=0.04) and at 3 years (hazard ratio, 0.72; 95% CI, 0.51 to 1.00; P=0.05) but not thereafter. There were 10 aneurysm-related deaths in the endovascular-repair group (2.3%) versus 16 in the open-repair group (3.7%) (P=0.22). Six aneurysm ruptures were confirmed in the endovascular-repair group versus none in the open-repair group (P=0.03). A significant interaction was observed between age and type of treatment (P=0.006); survival was increased among patients under 70 years of age in the endovascular-repair group but tended to be better among those 70 years of age or older in the open-repair group. Endovascular repair and open repair resulted in similar long-term survival. The perioperative survival advantage with endovascular repair was sustained for several years, but rupture after repair remained a concern. Endovascular repair led to increased long-term survival among younger patients but not among older patients, for whom a greater benefit from the endovascular approach had been expected. (Funded by the Department of Veterans Affairs Office of Research and Development; OVER ClinicalTrials.gov number, NCT00094575.).

  4. Endovascular vs medical management of acute ischemic stroke

    PubMed Central

    Ding, Dale; Starke, Robert M.; Mehndiratta, Prachi; Crowley, R. Webster; Liu, Kenneth C.; Southerland, Andrew M.; Worrall, Bradford B.

    2015-01-01

    Objective: To compare the outcomes between endovascular and medical management of acute ischemic stroke in recent randomized controlled trials (RCT). Methods: A systematic literature review was performed, and multicenter, prospective RCTs published from January 1, 2013, to May 1, 2015, directly comparing endovascular therapy to medical management for patients with acute ischemic stroke were included. Meta-analyses of modified Rankin Scale (mRS) and mortality at 90 days and symptomatic intracranial hemorrhage (sICH) for endovascular therapy and medical management were performed. Results: Eight multicenter, prospective RCTs (Interventional Management of Stroke [IMS] III, Local Versus Systemic Thrombolysis for Acute Ischemic Stroke [SYNTHESIS] Expansion, Mechanical Retrieval and Recanalization of Stroke Clots Using Embolectomy [MR RESCUE], Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands [MR CLEAN], Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness [ESCAPE], Extending the Time for Thrombolysis in Emergency Neurological Deficits–Intra-Arterial [EXTEND-IA], Solitaire With the Intention For Thrombectomy as Primary Endovascular Treatment [SWIFT PRIME], and Endovascular Revascularization With Solitaire Device Versus Best Medical Therapy in Anterior Circulation Stroke Within 8 Hours [REVASCAT]) comprising 2,423 patients were included. Meta-analysis of pooled data demonstrated functional independence (mRS 0–2) at 90 days in favor of endovascular therapy (odds ratio [OR] = 1.71; p = 0.005). Subgroup analysis of the 6 trials with large vessel occlusion (LVO) criteria also demonstrated functional independence at 90 days in favor of endovascular therapy (OR = 2.23; p < 0.00001). Subgroup analysis of the 5 trials that primarily utilized stent retriever devices (≥70%) in the intervention arm demonstrated functional independence at 90 days in favor of endovascular therapy (OR = 2.39; p < 0.00001). No difference was found for mortality at 90 days and sICH between endovascular therapy and medical management in all analyses and subgroup analyses. Conclusions: This meta-analysis provides strong evidence that endovascular intervention combined with medical management, including IV tissue plasminogen activator for eligible patients, improves the outcomes of appropriately selected patients with acute ischemic stroke in the setting of LVO. PMID:26537058

  5. Endovascular Versus Open Surgical Intervention in Patients with Takayasu's Arteritis: A Meta-analysis.

    PubMed

    Jung, Jae Hyun; Lee, Young Ho; Song, Gwan Gyu; Jeong, Han Saem; Kim, Jae-Hoon; Choi, Sung Jae

    2018-06-01

    Although medical treatment has advanced, surgical treatment is needed to control symptoms of Takayasu's arteritis (TA), such as angina, stroke, hypertension, or claudication. Endovascular or open surgical intervention is performed; however, there are few comparative studies on these methods. This meta-analysis and systematic review aimed to examine the outcome of surgical treatment of TA. A meta-analysis comparing outcomes of endovascular and open surgical intervention was performed using MEDLINE and Embase. This meta-analysis included only observational studies, and the evidence level was low to moderate. Data were pooled and analysed using a fixed or random effects model with the I 2 statistic. The included studies involved a total of 770 patients and 1363 lesions, with 389 patients treated endovascularly and 420 treated by surgical revascularization. Restenosis was more common with endovascular than open surgical intervention (odds ratio [OR] 5.18, 95% confidence interval [CI] 2.78-9.62; p < .001). In subgroup analysis according to the involved lesions, endovascular intervention patients showed more restenosis than open surgical intervention patients in the coronary artery, supra-aortic branches, and renal artery. In both the active and inactive stages, restenosis was more common in those treated endovascularly than in those treated by open surgery. However, stroke occurred less often with endovascular intervention than with open surgical intervention (OR 0.33, 95% CI 0.12-0.90; p = .003). Mortality and complications other than stroke and mortality did not differ between endovascular and open surgical intervention. This meta-analysis has shown a lower risk of restenosis with open surgical intervention than with endovascular intervention. Stroke was generally more common with open surgical intervention than with endovascular intervention. However, there were differences according to the location of the lesion, and the risk of stroke in open surgery is higher when the supra-aortic branches are involved rather than the renal arteries. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  6. Endovascular or open repair strategy for ruptured abdominal aortic aneurysm: 30 day outcomes from IMPROVE randomised trial.

    PubMed

    Powell, Janet T; Sweeting, Michael J; Thompson, Matthew M; Ashleigh, Ray; Bell, Rachel; Gomes, Manuel; Greenhalgh, Roger M; Grieve, Richard; Heatley, Francine; Hinchliffe, Robert J; Thompson, Simon G; Ulug, Pinar

    2014-01-13

    To assess whether a strategy of endovascular repair (if aortic morphology is suitable, open repair if not) versus open repair reduces early mortality for patients with suspected ruptured abdominal aortic aneurysm. Randomised controlled trial. 30 vascular centres (29 UK, 1 Canadian), 2009-13. 613 eligible patients (480 men) with a clinical diagnosis of ruptured aneurysm. 316 patients were randomised to the endovascular strategy (275 confirmed ruptures, 174 anatomically suitable for endovascular repair) and 297 to open repair (261 confirmed ruptures). 30 day mortality, with 24 hour and in-hospital mortality, costs, and time and place of discharge as secondary outcomes. 30 day mortality was 35.4% (112/316) in the endovascular strategy group and 37.4% (111/297) in the open repair group: odds ratio 0.92 (95% confidence interval 0.66 to 1.28; P=0.62); odds ratio after adjustment for age, sex, and Hardman index 0.94 (0.67 to 1.33). Women may benefit more than men (interaction test P=0.02) from the endovascular strategy: odds ratio 0.44 (0.22 to 0.91) versus 1.18 (0.80 to 1.75). 30 day mortality for patients with confirmed rupture was 36.4% (100/275) in the endovascular strategy group and 40.6% (106/261) in the open repair group (P=0.31). More patients in the endovascular strategy than in the open repair group were discharged directly to home (189/201 (94%) v 141/183 (77%); P<0.001). Average 30 day costs were similar between the randomised groups, with an incremental cost saving for the endovascular strategy versus open repair of £1186 (€1420; $1939) (95% confidence interval -£625 to £2997). A strategy of endovascular repair was not associated with significant reduction in either 30 day mortality or cost. Longer term cost effectiveness evaluations are needed to assess the full effects of the endovascular strategy in both men and women. Current Controlled Trials ISRCTN48334791.

  7. A collaborative sequential meta-analysis of individual patient data from randomized trials of endovascular therapy and tPA vs. tPA alone for acute ischemic stroke: ThRombEctomy And tPA (TREAT) analysis: statistical analysis plan for a sequential meta-analysis performed within the VISTA-Endovascular collaboration.

    PubMed

    MacIsaac, Rachael L; Khatri, Pooja; Bendszus, Martin; Bracard, Serge; Broderick, Joseph; Campbell, Bruce; Ciccone, Alfonso; Dávalos, Antoni; Davis, Stephen M; Demchuk, Andrew; Diener, Hans-Christoph; Dippel, Diederik; Donnan, Geoffrey A; Fiehler, Jens; Fiorella, David; Goyal, Mayank; Hacke, Werner; Hill, Michael D; Jahan, Reza; Jauch, Edward; Jovin, Tudor; Kidwell, Chelsea S; Liebeskind, David; Majoie, Charles B; Martins, Sheila Cristina Ouriques; Mitchell, Peter; Mocco, J; Muir, Keith W; Nogueira, Raul; Saver, Jeffrey L; Schonewille, Wouter J; Siddiqui, Adnan H; Thomalla, Götz; Tomsick, Thomas A; Turk, Aquilla S; White, Philip; Zaidat, Osama; Lees, Kennedy R

    2015-10-01

    Endovascular treatment has been shown to restore blood flow effectively. Second-generation medical devices such as stent retrievers are now showing overwhelming efficacy in clinical trials, particularly in conjunction with intravenous recombinant tissue plasminogen activator. This statistical analysis plan utilizing a novel, sequential approach describes a prospective, individual patient data analysis of endovascular therapy in conjunction with intravenous recombinant tissue plasminogen activator agreed upon by the Thrombectomy and Tissue Plasminogen Activator Collaborative Group. This protocol will specify the primary outcome for efficacy, as 'favorable' outcome defined by the ordinal distribution of the modified Rankin Scale measured at three-months poststroke, but with modified Rankin Scales 5 and 6 collapsed into a single category. The primary analysis will aim to answer the questions: 'what is the treatment effect of endovascular therapy with intravenous recombinant tissue plasminogen activator compared to intravenous tissue plasminogen activator alone on full scale modified Rankin Scale at 3 months?' and 'to what extent do key patient characteristics influence the treatment effect of endovascular therapy?'. Key secondary outcomes include effect of endovascular therapy on death within 90 days; analyses of modified Rankin Scale using dichotomized methods; and effects of endovascular therapy on symptomatic intracranial hemorrhage. Several secondary analyses will be considered as well as expanding patient cohorts to intravenous recombinant tissue plasminogen activator-ineligible patients, should data allow. This collaborative meta-analysis of individual participant data from randomized trials of endovascular therapy vs. control in conjunction with intravenous thrombolysis will demonstrate the efficacy and generalizability of endovascular therapy with intravenous thrombolysis as a concomitant medication. © 2015 World Stroke Organization.

  8. Endovascular Treatments in Combination with Extracranial-Intracranial Bypass for Complex Intracranial Aneurysms.

    PubMed

    Sato, Kenichi; Endo, Hidenori; Fujimura, Miki; Endo, Toshiki; Matsumoto, Yasushi; Shimizu, Hiroaki; Tominaga, Teiji

    2018-05-01

    Although most intracranial aneurysms can be treated with microsurgery or endovascular procedure alone, a subset of aneurysms may require a combined approach. The purpose of this study was to assess the efficacy of endovascular interventions combined with bypass surgery for the treatment of complex intracranial aneurysms. We retrospectively reviewed medical records from a prospectively maintained patient database to identify patients who underwent endovascular treatment of an intracranial aneurysm at our institutes between 2007 and 2017. We recruited patients who received a preplanned combination of endovascular treatment and extracranial-intracranial bypass surgery. Forty-four patients (44 aneurysms) were treated with a combined approach. Twenty-four patients presented with subarachnoid hemorrhage. Treatment strategies included endovascular parent artery occlusion with the bypass surgery to restore cerebral blood flow (n = 12), endovascular trapping with bypass surgery to isolate incorporated branches (n = 12), and intra-aneurysmal coil embolization with bypass surgery to isolate incorporated branches (n = 20). During a mean period of 35.6 months, follow-up catheter angiography was performed in 35 of 44 patients (79.5%) and demonstrated complete aneurysm obliteration in 29 patients (82.9%) and bypass patency in 33 (94.3%). The postoperative aneurysm-related mortality and morbidity rates were 6.8% and 13.6%, respectively. Combined endovascular and surgical bypass procedures are useful for the treatment of complex intracranial aneurysms when conventional surgical or endovascular techniques are not feasible and show acceptable rates of morbidity and mortality. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Is Conventional Open Repair for Abdominal Aortic Aneurysm Feasible in Nonagenarians?

    PubMed

    Uehara, Kyokun; Matsuda, Hitoshi; Inoue, Yosuke; Omura, Atsushi; Seike, Yoshimasa; Sasaki, Hiroaki; Kobayashi, Junjiro

    2017-09-25

    Background : Although endovascular repair for abdominal aortic aneurysm has been found to be beneficial in very elderly patients, some patients have contraindications to this procedure. For nonagenarians, the results of open repair remain unclear. The purpose of this study was to compare the outcomes of open vs. endovascular repair for abdominal aortic aneurysm in nonagenarian patients. Methods and Results : Fourteen patients undergoing open surgical repair and 24 undergoing endovascular repair for abdominal aortic aneurysm were evaluated. There was no significant difference in early mortality between the open and endovascular groups (0% vs. 4.1%, p=0.16). The open repair group required much longer hospital stays (26.4 vs. 10.6 days, respectively, p=0.003). Finally, 12 patients (86%) undergoing open repair vs. 21 (88%) undergoing endovascular repair returned home (p=0.49). During a mean follow-up period of 23.4±23.5 months, cumulative estimated 1- and 3-year survival rates were 90.0% and 48.0%, respectively in the open repair group and 90.6% and 54.9%, respectively in the endovascular repair group (p=0.51). Conclusion : Although endovascular repair for abdominal aortic aneurysm was superior in terms of recovery, the results of conventional open repair were acceptable even in nonagenarian patients. Open repair remains an alternative for patients with contraindications to endovascular repair.

  10. Effects of electrocautery to provoke endovascular thermal injury.

    PubMed

    Rossi, Fabio Henrique; Izukawa, Nilo Mitsuru; Silva, Domingos Guerino; Chen, Juliana; Prakasan, Akash Kuzhiparambil; Zamorano, Mabel Moura Barros; Silva, Lílian Mary

    2011-10-01

    To investigate the effects of a new electrocautery device to provoke endovascular venous thermal injury. An experimental endovascular electrocautery was placed inside eight ex-vivo bovine saphenous veins models. Each one was divided in eight segments and progressive intensities of electric energy liberated. The macroscopic and microscopic effects were analyzed. Forty bovine saphenous veins segments were studied. The higher the electric energy applied the greater the nuclear picnosis and more intense the cytoplasmatic shrinkage and electrocoagulation effects. The experimental endovascular electrocautery device demonstrated to be both capable of inducing the destruction of the intimal layers of the studied vein model and provoke endovascular thermal injury.

  11. Thoracic aortic aneurysms and dissections: endovascular treatment.

    PubMed

    Baril, Donald T; Cho, Jae S; Chaer, Rabih A; Makaroun, Michel S

    2010-01-01

    The treatment of thoracic aortic disease has changed radically with the advances made in endovascular therapy since the concept of thoracic endovascular aortic repair was first described 15 years ago. Currently, there is a diverse array of endografts that are commercially available to treat the thoracic aorta. Multiple studies, including industry-sponsored and single-institution reports, have demonstrated excellent outcomes of thoracic endovascular aortic repair for the treatment of thoracic aortic aneurysms, with less reported perioperative morbidity and mortality in comparison with conventional open repair. Additionally, similar outcomes have been demonstrated for the treatment of type B dissections. However, the technology remains relatively novel, and larger studies with longer term outcomes are necessary to more fully evaluate the role of endovascular therapy for the treatment of thoracic aortic disease. This review examines the currently available thoracic endografts, preoperative planning for thoracic endovascular aortic repair, and outcomes of thoracic endovascular aortic repair for the treatment of both thoracic aortic aneurysms and type B aortic dissections. Mt Sinai J Med 77:256-269, 2010. (c) 2010 Mount Sinai School of Medicine.

  12. Aortic Arch Aneurysms: Treatment with Extra anatomical Bypass and Endovascular Stent-Grafting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kato, Noriyuki; Shimono, Takatsugu; Hirano, Tadanori

    2002-10-15

    Endovascular repair of thoracic aortic aneurysms is emerging as an attractive alternative to surgical graft replacement. However,patients with aortic arch aneurysms are often excluded from the target of endovascular repair because of lack of suitable landing zones, especially at the proximal ones. In this paper we describe our method for treating patients with aortic arch aneurysms using a combination of extra anatomical bypass surgery and endovascular stent-grafting.

  13. Simulation and augmented reality in endovascular neurosurgery: lessons from aviation.

    PubMed

    Mitha, Alim P; Almekhlafi, Mohammed A; Janjua, Major Jameel J; Albuquerque, Felipe C; McDougall, Cameron G

    2013-01-01

    Endovascular neurosurgery is a discipline strongly dependent on imaging. Therefore, technology that improves how much useful information we can garner from a single image has the potential to dramatically assist decision making during endovascular procedures. Furthermore, education in an image-enhanced environment, especially with the incorporation of simulation, can improve the safety of the procedures and give interventionalists and trainees the opportunity to study or perform simulated procedures before the intervention, much like what is practiced in the field of aviation. Here, we examine the use of simulators in the training of fighter pilots and discuss how similar benefits can compensate for current deficiencies in endovascular training. We describe the types of simulation used for endovascular procedures, including virtual reality, and discuss the relevant data on its utility in training. Finally, the benefit of augmented reality during endovascular procedures is discussed, along with future computerized image enhancement techniques.

  14. Towards an entirely endovascular aortic world: an update of techniques and outcomes for endovascular and open treatment of type I, II, and III endoleaks.

    PubMed

    Mangialardi, Nicola; Orrico, Matteo; Ronchey, Sonia; Praquin, Barbara; Alberti, Vittorio; Setacci, Carlo

    2016-10-01

    Endovascular aneurysm repair (EVAR) is largely the most adopted strategy for aneurysmal disease of the aorta. Nevertheless, the high incidence of reintervention makes it difficult to identify EVAR as a definitive solution; in particular, the most frequent indication of reintervention is endoleak, which is defined as persistent flow into the aneurysmal sac from different sources. Several treatment strategies are described. A contemporary literature search was performed with the intent of describing techniques and outcomes of endovascular and open strategies to type I, II, and III endoleak. Described techniques and outcomes were organized by indication (type I, II, and III endoleak) and by type of approach (endovascular, open, and laparoscopic) to give an overview of the current status of the treatment for the three most frequent types of endoleak. Several endovascular means are described in the literature for the treatment of endoleak.

  15. Open surgery versus endovascular approach in treatment of extracranial carotid artery aneurysms.

    PubMed

    Ni, Leng; Weng, Huiling; Pu, Zuo; Zheng, Yuehong; Liu, Bao; Ye, Wei; Zeng, Rong; Liu, Changwei

    2018-05-01

    The objective of this study was to investigate and to compare the early and long-term results of open surgery with endovascular intervention in the treatment of extracranial carotid artery aneurysms (ECCAs). A retrospective review of patients diagnosed with ECCAs who underwent open surgical or endovascular treatment from 1997 to 2017 was performed. Clinical characteristics, aneurysm profile, and treatment outcomes were recorded. Early results (<30 days) were evaluated in terms of mortality, perioperative stroke or transient ischemic attack, and cranial nerve injury. Late results were analyzed in terms of both overall and stroke-free survival and freedom from reinterventions. A total of 48 patients with ECCAs including 34 (70.8%) true aneurysms and 14 (29.2%) pseudoaneurysms were treated. The median age was 51 years, and 19 patients (39.6%) were men; 41 patients (85.4%) had symptoms, whereas 7 (14.6%) were asymptomatic. Among 48 patients, 32 patients (66.7%) underwent open surgery; endovascular repair was performed on 16 patients (33.3%). The 30-day stroke or transient ischemic attack rate was not significantly different between the open group (6.3% [2/32]) and the endovascular group (0% [0/16]; P = .307). Cranial nerve injuries occurred in eight patients in the open group (25%) and in no patient in the endovascular group (0%; P = .029). Median length of stay was significantly longer in the open group than in the endovascular group (20 vs 14 days, respectively; P = .013). Median follow-up was 46 months (range, 0-20 years), and no aneurysm-related death occurred during this period. Overall survival rates at 5 years were 88.7% (standard error [SE], 0.08) in the open group and 91.7% (SE, 0.08) in the endovascular group (P = .319; log-rank, .992). For the same time interval, stroke-free survival rates were 85.2% (SE, 0.10) in the open group and 92.2% (SE, 0.07) in the endovascular group (P = .653; log-rank, .201). One patient (1/28 [3.6%]) in the open group and two patients (2/16 [12.5%]) in the endovascular group underwent endovascular reinterventions because of restenosis during the follow-up period. Reintervention-free survival rates were 90.9% in the open group (SE, 0.09) and 69.2% in the endovascular group (SE, 0.21; P = .082; log-rank, 3.016). In this single-institutional experience, both operative and endovascular interventions for ECCAs provided acceptable early and 5-year results. The endovascular approach had significantly less cranial nerve injury and shorter length of hospital stay. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  16. Hybrid and endovascular therapy for extensive thoracoabdominal aortic disease.

    PubMed

    Riga, Celia V; Bicknell, Colin D; Cheshire, Nicholas J W

    2010-12-01

    The past 4 decades have witnessed tremendous strides in the evolution of endovascular technology with increased operator experience, greater availability of more sophisticated and versatile endovascular devices, and advances in imaging modalities. In an attempt to limit the physiologic derangements associated with aortic crossclamping and extensive tissue dissection during traditional open surgical repair of extensive thoracoabdominal aortic aneurysms, less invasive strategies have been explored using endovascular technology: hybrid approaches and solely endovascular techniques. This article describes these techniques and their advantages, their current role in thoracoabdominal aortic aneurysm repair and potential future developments in this field. Copyright © 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  17. EndoVascular and Hybrid Trauma Management (EVTM) for Blunt Innominate Artery Injury with Ongoing Extravasation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bilos, Linda, E-mail: linda.bilos@regionorebrolan.se; Pirouzram, Artai; Toivola, Asko

    Innominate artery (IA) traumatic injuries are rare but life-threatening, with high mortality and morbidity. Open surgical repair is the treatment of choice but is technically demanding. We describe a case of blunt trauma to the IA with ongoing bleeding, treated successfully by combined (hybrid) endovascular and open surgery. The case demonstrates the immediate usage of modern endovascular and surgical tools as part of endovascular and hybrid trauma management.

  18. A Matched Case-Control Study on Open and Endovascular Treatment of Popliteal Artery Aneurysms.

    PubMed

    Dorigo, W; Fargion, A; Masciello, F; Piffaretti, G; Pratesi, G; Giacomelli, E; Pratesi, C

    2018-01-01

    To compare early and late results of open and endovascular management of popliteal artery aneurysm in a retrospective single-center matched case-control study Methods: From 1981 to 2015, 309 consecutive interventions for popliteal artery aneurysm were performed in our institution, in 59 cases with endovascular repair and in 250 cases with open repair. Endovascular repair was preferred in older asymptomatic patients, while open repair was offered more frequently to patients with a thrombosed popliteal artery aneurysm and a poor run-off status. A one-to-one coarsened exact matching on the basis of the baseline demographic, clinical, and anatomical covariates significantly different between the two treatment options was performed and two equivalent groups of 56 endovascular repairs and open repairs were generated. The two groups were compared in terms of perioperative results with χ 2 test and of follow-up outcomes with the Kaplan-Meier curves and log-rank test. There were no differences between the two groups in terms of perioperative outcomes. Median duration of follow-up was 38 months. Five-year survival rates were 94% in endovascular repair group and 89.5% in open repair group (p = 0.4, log-rank 0.6). Primary patency rates at 1, 3, and 5 years were 81%, 78%, and 72% in endovascular repair group and 82.5%, 80%, and 64% in open repair group (p = 0.8, log-rank 0.01). Freedom from reintervention at 5 years was 65.5% in endovascular repair group and 76% in open repair group (p = 0.2, log-rank 1.2). Secondary patency at 1, 3, and 5 years was 94%, 86%, and 74% in endovascular repair group, and 94%, 89%, and 71% in open repair group, respectively (p = 0.9, log-rank 0.01). The rates of limb preservation at 5 years were 94% in endovascular repair group and 86.4% in open repair group (p = 0.3, log-rank 0.8). Open repair and endovascular repair of popliteal artery aneurysms provided in this retrospective single-center experience similar perioperative and follow-up results in equivalent groups of patients.

  19. Effectiveness of open versus endovascular abdominal aortic aneurysm repair in population settings: A systematic review of statewide databases.

    PubMed

    Williams, Christopher R; Brooke, Benjamin S

    2017-10-01

    Patient outcomes after open abdominal aortic aneurysm and endovascular aortic aneurysm repair have been widely reported from several large, randomized, controlled trials. It is not clear whether these trial outcomes are representative of abdominal aortic aneurysm repair procedures performed in real-world hospital settings across the United States. This study was designed to evaluate population-based outcomes after endovascular aortic aneurysm repair versus open abdominal aortic aneurysm repair using statewide inpatient databases and examine how they have helped improve our understanding of abdominal aortic aneurysm repair. A systematic search of MEDLINE, EMBASE, and CINAHL databases was performed to identify articles comparing endovascular aortic aneurysm repair and open abdominal aortic aneurysm repair using data from statewide inpatient databases. This search was limited to studies published in the English language after 1990, and abstracts were screened and abstracted by 2 authors. Our search yielded 17 studies published between 2004 and 2016 that used data from 29 different statewide inpatient databases to compare endovascular aortic aneurysm repair versus open abdominal aortic aneurysm repair. These studies support the randomized, controlled trial results, including a lower mortality associated with endovascular aortic aneurysm repair extended from the perioperative period up to 3 years after operation, as well as a higher complication rate after endovascular aortic aneurysm repair. The evidence from statewide inpatient database analyses has also elucidated trends in procedure volume, patient case mix, volume-outcome relationships, and health care disparities associated with endovascular aortic aneurysm repair versus open abdominal aortic aneurysm repair. Population analyses of endovascular aortic aneurysm repair and open abdominal aortic aneurysm repair using statewide inpatient databases have confirmed short- and long-term mortality outcomes obtained from large, randomized, controlled trials. Moreover, these analyses have allowed us to assess the effect of endovascular aortic aneurysm repair adoption on population outcomes and patient case mix over time. Published by Elsevier Inc.

  20. Recovery of Third Nerve Palsy after Endovascular Packing of Internal Carotid-Posterior Communicating Artery Aneurysms

    PubMed Central

    Mavilio, N.; Pisani, R.; Rivano, C.; Testa, V.; Spaziante, R.; Rosa, M.

    2000-01-01

    Summary Endovascular packing of intracranial aneurysm with preservation of the parent vessel has become in many cases a valid alternative to surgical clipping. Regression of oculomotor disorders after clipping of internal carotid-posterior communicating artery (ICA-PCoA) aneurysms has been well assessed. This report focuses on the reversal of third nerve palsy after endovascular packing of ICA-PCoA aneurysms. To this end, clinical appearances, neuroradiological features, and endovascular interventional procedures of six treated patient are reported and discussed in the light of the very few previous case observations found in the literature. Results indicate that endovascular packing of ICA-PCoA aneurysms may produce effective recovery of correlated third nerve dysfunction. PMID:20667199

  1. First long-term evidence supporting endovascular repair of abdominal aortic aneurysms.

    PubMed

    Indes, Jeffrey E; Muhs, Bart E; Dardik, Alan

    2013-04-01

    The traditional method of treating abdominal aortic aneurysms with open surgical repair has been steadily replaced by endovascular repair, thought to be a more minimally invasive approach. It is not known, however, whether the endovascular approach is truly less invasive for operative physiology; in addition, this approach has a different spectrum of complications. As such, it is uncertain whether elective endovascular repair of nonruptured aortic aneurysms reduces long-term morbidity and mortality compared with traditional open approaches. In this article, the authors evaluate a recent publication investigating long-term outcomes of a prospective randomized multicenter trial evaluating patients with asymptomatic abdominal aortic aneurysms treated with either endovascular or open repair, and discuss the results in the context of current evidence.

  2. Endovascular stenting of a chronic ruptured type B thoracic aortic dissection, a second chance: a case report.

    PubMed

    Arshad, Ali; Khan, Sumaira L; Whitaker, Simon C; Macsweeney, Shane T

    2008-02-07

    We aim to highlight the need for awareness of late complications of endovascular thoracic aortic stenting and the need for close follow-up of patients treated by this method. We report the first case in the English literature of an endovascular repair of a previously stented, ruptured chronic Stanford type B thoracic aortic dissection re-presenting with a type III endoleak of the original repair. Endovascular thoracic stenting is now a widely accepted technique for the treatment of thoracic aortic dissection and its complications. Long term follow up is necessary to ensure that late complications are identified and treated appropriately. In this case of type III endoleak, although technically challenging, endovascular repair was feasible and effective.

  3. Endovascular Treatment of Various Aortic Pathologies: Review of the Latest Data and Technologies.

    PubMed

    Maeda, Koji; Ohki, Takao; Kanaoka, Yuji

    2018-06-01

    The technologies and innovations applicable to endovascular treatment for complex aortic pathologies have progressed rapidly over the last two decades. Although the initial outcomes of an endovascular aortic repair have been excellent, as long-term data became available, complications including endoleaks, endograft migration, and endograft infection have become apparent and are of concern. Previously, the indication for endovascular therapy was restricted to descending thoracic aortic aneurysms and abdominal aortic aneurysms. However, its indication has expanded along with the improvement of techniques and devices, and currently, it has become possible to treat pararenal aortic aneurysms and Crawford type 4 thoracoabdominal aortic aneurysm (TAAA) using the off-the-shelf devices. Additionally, custom-made devices allow for the treatment of arch or more extensive TAAAs. Endovascular treatment is applied not only to aneurysms but also to acute/chronic dissections. However, long-term outcomes are still unclear. This article provides an overview of available devices and the results of endovascular treatment for various aortic pathologies.

  4. Mechanical Thrombectomy-Ready Comprehensive Stroke Center Requirements and Endovascular Stroke Systems of Care: Recommendations from the Endovascular Stroke Standards Committee of the Society of Vascular and Interventional Neurology (SVIN)

    PubMed Central

    English, Joey D.; Yavagal, Dileep R.; Gupta, Rishi; Janardhan, Vallabh; Zaidat, Osama O.; Xavier, Andrew R.; Nogueira, Raul G.; Kirmani, Jawad F.; Jovin, Tudor G.

    2016-01-01

    Five landmark multicenter, prospective, randomized, open-label, blinded end point clinical trials have recently demonstrated significant clinical benefit of endovascular therapy with mechanical thrombectomy in acute ischemic stroke (AIS) patients presenting with proximal intracranial large vessel occlusions. The Society of Vascular and Interventional Neurology (SVIN) appointed an expert writing committee to summarize this new evidence and make recommendations on how these data should guide emergency endovascular therapy for AIS patients. PMID:27051410

  5. Endovascular stents: a review of their use in peripheral arterial disease.

    PubMed

    Kudagi, Vinod S; White, Christopher J

    2013-06-01

    Technological advances in the past decade have shifted revascularization strategies from traditional open surgical approaches toward lower-morbidity percutaneous endovascular treatments for patients with lower extremity peripheral arterial disease (PAD). The continuing advances in stent design, more than any other advances, have fueled the growth of catheter-based procedures by improving the safety, durability, and predictability of percutaneous revascularization. Although the 2007 TransAtlantic Inter-Society Consensus (TASC) guidelines recommend endovascular therapy for type A and B aortoiliac and femoropopliteal lesions, recent developments in stent technology and increased experience of interventionists have suggested that a strategy of endovascular therapy first is appropriate in experienced hands for TASC type D lesions. The role of endovascular interventions is also expanding in the treatment of limb-threatening ischemia.

  6. Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrison, Gareth J., E-mail: garethjamesharrison@yahoo.co.uk; Antoniou, George A., E-mail: antoniou.ga@hotmail.com; Torella, Francesco, E-mail: francesco.torella@rlbuht.nhs.uk

    An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion,more » EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.« less

  7. Endovascular therapy for acute ischemic stroke.

    PubMed

    Broderick, Joseph P

    2009-03-01

    To review advances in endovascular therapy for acute ischemic stroke. Data from primate studies, randomized studies of intravenous recombinant tissue-type plasminogen activator, and nonrandomized and randomized studies of endovascular therapy were reviewed. Clinical trial data demonstrate the superiority of endovascular treatment with thrombolytic medication or mechanical methods to reopen arteries compared with control patients from the PROACT II Trial treated with heparin alone. However, these same clinical trials, as well as preclinical primate models, indicate that recanalization, whether by endovascular approaches or standard-dose recombinant tissue-type plasminogen activator, is unlikely to improve clinical outcome after a certain time point. Although the threshold beyond which reperfusion has no or little benefit has yet to be conclusively defined, accumulated data to this point indicate an overall threshold of approximately 6 to 7 hours. In addition, although the risk of symptomatic intracerebral hemorrhage is similar in trials of intravenous lytics and endovascular approaches, endovascular approaches have distinctive risk profiles that can impact outcome. The treatment of acute ischemic stroke is evolving with new tools to reopen arteries and salvage the ischemic brain. Ongoing randomized trials of these new approaches are prerequisite next steps to demonstrate whether reperfusion translates into clinical effectiveness. Physiologic time to reperfusion will remain critical no matter which tools prove most effective and safest.

  8. Functional outcome after primary endovascular therapy or IV thrombolysis alone for stroke. An observational, comparative effectiveness study.

    PubMed

    Abilleira, Sònia; Ribera, Aida; Dávalos, Antonio; Ribó, Marc; Chamorro, Angel; Cardona, Pere; Molina, Carlos A; Martínez-Yélamos, Antonio; Urra, Xabier; Dorado, Laura; Roquer, Jaume; Martí-Fàbregas, Joan; Aja, Lucía; Tomasello, Alejandro; Castaño, Carlos; Blasco, Jordi; Cánovas, David; Castellanos, Mar; Krupinski, Jerzy; Guimaraens, Leopoldo; Perendreu, Joan; Ustrell, Xavier; Purroy, Francisco; Gómez-Choco, Manuel; Baiges, Joan Josep; Cocho, Dolores; Saura, Júlia; Gallofré, Miquel

    2014-01-01

    Among the acute ischemic stroke patients with large vessel occlusions and contraindications for the use of IV thrombolysis, mainly on oral anticoagulation or presenting too late, primary endovascular therapy is often performed as an alternative to the standard therapy even though evidence supporting the use of endovascular reperfusion therapies is not yet established. Using different statistical approaches, we compared the functional independence rates at 3 months among patients undergoing primary endovascular therapy and patients treated only with IV thrombolysis. We used data from a prospective, government-mandated and externally audited registry of reperfusion therapies for ischemic stroke (January 2011 to November 2012). Patients were selected if treated with either IV thrombolysis alone (n = 1,582) or primary endovascular thrombectomy (n = 250). A series of exclusions were made to homogenize the clinical characteristics among the two groups. We then carried out multivariate logistic regression and propensity score matching analyses on the final study sample (n = 1,179) to compare functional independence at 3 months, as measured by the modified Rankin scale scores 0-2, between the two groups. The unadjusted likelihood of good outcome was poorer among the endovascular group (OR: 0.69; 95% CI: 0.47-1.0). After adjustment, no differences by treatment modality were seen (OR: 1.51; 95% CI: 0.93-2.43 for primary endovascular therapy). Patients undergoing endovascular thrombectomy within 180-270 min (OR: 2.89; 95% CI: 1.17-7.15) and patients with severe strokes (OR: 1.84; 95% CI: 1.02-3.35) did better than their intravenous thrombolysis counterparts. The propensity score-matched analyses with and without adjustment by additional covariates showed that endovascular thrombectomy was as effective as intravenous thrombolysis alone in achieving functional independence (OR for unadjusted propensity score matched: 1.35; 95% CI: 0.9-2.02, OR for adjusted propensity score matched: 1.45; 95% CI: 0.91-2.32). This comparative effectiveness study shows that in ischemic stroke patients with contraindications for IV thrombolysis, primary endovascular treatment might be an alternative therapy at least as effective as IV thrombolysis alone. Randomized controlled trials are urgently needed. © 2014 S. Karger AG, Basel.

  9. Lower extremity endovascular interventions: can we improve cost-efficiency?

    PubMed

    O'Brien-Irr, Monica S; Harris, Linda M; Dosluoglu, Hasan H; Dayton, Merril; Dryjski, Maciej L

    2008-05-01

    Management of lower extremity arterial disease with endovascular intervention is on the rise. Current practice patterns vary widely across and within specialty practices that perform endovascular intervention. This study evaluated reimbursement and costs of different approaches for offering endovascular intervention and identified strategies to improve cost-efficiency. The medical records of all patients admitted to a university health system during 2005 for an endovascular intervention were retrospectively reviewed. Procedure type, setting, admission status, and financial data were recorded. Groups were compared using analysis of variance, Student t test for independent samples, and chi2. A total of 296 endovascular interventions were completed, and 184 (62%) met inclusion criteria. Atherectomy and stenting were significantly more costly when performed in the operating room than in the radiology suite: atherectomy, dollars 6596 vs dollars 4867 (P = .002); stent, dollars 5884 vs dollars 3292, (P < .001); angioplasty, dollars 2251 vs dollars 1881 (P = .46). Reimbursement was significantly higher for inpatient vs ambulatory admissions (P < .001). Costs were lowest when the endovascular intervention was done in the radiology suite on an ambulatory basis and highest when done as an inpatient in the operating room (dollars 5714 vs dollars 12,278; P < .001). Contribution margins were significantly higher for inpatients. Net profit was appreciated only for interventions done as an inpatient in the radiology suite. Reimbursement, contribution margins, and net profit were significantly lower among private pay patients in both the ambulatory and inpatient setting. The 30-day hospital readmission after ambulatory procedures was seven patients (6%). Practice patterns for endovascular interventions differ considerably. Costs vary by procedure and setting, and reimbursement depends on admission status and accurate documentation; these dynamics affect affordability. Organizing vascular services within a hub will ensure that care is delivered in the most cost-efficient manner. Guidelines may include designating the radiology suite as the primary venue for endovascular interventions because it is less costly than the operating room. Selective stenting policies should be considered. Contracts with private insurers must include carve-outs for stent costs and commensurate reimbursement for ambulatory procedures, and Current Procedural Terminology (CPT; American Medical Association, Chicago, Ill) coding must be proficient to make ambulatory endovascular interventions fiscally acceptable.

  10. Endovascular treatment of head and neck arteriovenous malformations.

    PubMed

    Dmytriw, A A; Ter Brugge, K G; Krings, T; Agid, R

    2014-03-01

    Head and neck arteriovenous malformations (H&N AVM) are associated with considerable clinical and psychosocial burden and present a significant treatment challenge. We evaluated the presentation, response to treatment, and outcome of patients with H&N AVMs treated by endovascular means at our institution. Patients with H&N AVMs treated by endovascular means from 1984 to 2012 were evaluated retrospectively. These included AVMs involving the scalp, orbit, maxillofacial, and upper neck localizations. Patient's clinical files, radiological images, catheter angiograms, and surgical reports were reviewed. Eighty-nine patients with H&N AVMs (46 females, 43 males; 48 small, 41 large) received endovascular therapy. The goals of treatment were curative (n = 30), palliative (n = 34), or presurgical (n = 25). The total number of endovascular treatment sessions was 244 (average of 1.5 per patient). The goal of treatment was met in 92.1 % of cases. Eventual cure was achieved in 42 patients accounting for 58.4 % (52/89) of all patients who underwent treatment for any goal. Twenty-eight of these patients were cured by embolization alone (28/89, 31.4 %) of which 18 were single-hole AVFs. Twenty-four were cured by planned surgical excision after presurgical embolization (24/89, 27 %). Seven patients (7/89, 7.2 %) suffered transient and two (2/89, 2.2 %) permanent endovascular treatment complications. Endovascular treatment is effective for H&N AVMs and relatively safe. It is particularly effective for symptom palliation and presurgical aid. Embolization is curative mostly in small lesions and single-hole fistulas. In patients with large non-curable H&N AVMs, endovascular therapy is often the only palliative option.

  11. Intravenous thrombolysis and endovascular therapy for acute ischemic stroke with internal carotid artery occlusion: a systematic review of clinical outcomes.

    PubMed

    Mokin, Maxim; Kass-Hout, Tareq; Kass-Hout, Omar; Dumont, Travis M; Kan, Peter; Snyder, Kenneth V; Hopkins, L Nelson; Siddiqui, Adnan H; Levy, Elad I

    2012-09-01

    Strokes secondary to acute internal carotid artery (ICA) occlusion are associated with extremely poor prognosis. The best treatment approach to acute stroke in this setting is unknown. We sought to determine clinical outcomes in patients with acute ischemic stroke attributable to ICA occlusion treated with intravenous (IV) systemic thrombolysis or intra-arterial endovascular therapy. Using the PubMed database, we searched for studies that included patients with acute ischemic stroke attributable to ICA occlusion who received treatment with IV thrombolysis or intra-arterial endovascular interventions. Studies providing data on functional outcomes beyond 30 days and mortality and symptomatic intracerebral hemorrhage (sICH) rates were included in our analysis. We compared the proportions of patients with favorable functional outcomes, sICH, and mortality rates in the 2 treatment groups by calculating χ(2) and confidence intervals for odds ratios. We identified 28 studies with 385 patients in the IV thrombolysis group and 584 in the endovascular group. Rates of favorable outcomes and sICH were significantly higher in the endovascular group than the IV thrombolysis-only group (33.6% vs 24.9%, P=0.004 and 11.1% vs 4.9%, P=0.001, respectively). No significant difference in mortality rate was found between the groups (27.3% in the IV thrombolysis group vs 32.0% in the endovascular group; P=0.12). According to our systematic review, endovascular treatment of acute ICA occlusion results in improved clinical outcomes. A higher rate of sICH after endovascular treatment does not result in increased overall mortality rate.

  12. Three-dimensional (3D) printed endovascular simulation models: a feasibility study.

    PubMed

    Mafeld, Sebastian; Nesbitt, Craig; McCaslin, James; Bagnall, Alan; Davey, Philip; Bose, Pentop; Williams, Rob

    2017-02-01

    Three-dimensional (3D) printing is a manufacturing process in which an object is created by specialist printers designed to print in additive layers to create a 3D object. Whilst there are initial promising medical applications of 3D printing, a lack of evidence to support its use remains a barrier for larger scale adoption into clinical practice. Endovascular virtual reality (VR) simulation plays an important role in the safe training of future endovascular practitioners, but existing VR models have disadvantages including cost and accessibility which could be addressed with 3D printing. This study sought to evaluate the feasibility of 3D printing an anatomically accurate human aorta for the purposes of endovascular training. A 3D printed model was successfully designed and printed and used for endovascular simulation. The stages of development and practical applications are described. Feedback from 96 physicians who answered a series of questions using a 5 point Likert scale is presented. Initial data supports the value of 3D printed endovascular models although further educational validation is required.

  13. A Novel Technique for Endovascular Removal of Large Volume Right Atrial Tumor Thrombus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nickel, Barbara, E-mail: nickel.ba@gmail.com; McClure, Timothy, E-mail: tmcclure@gmail.com; Moriarty, John, E-mail: jmoriarty@mednet.ucla.edu

    Venous thromboembolic disease is a significant cause of morbidity and mortality, particularly in the setting of large volume pulmonary embolism. Thrombolytic therapy has been shown to be a successful treatment modality; however, its use somewhat limited due to the risk of hemorrhage and potential for distal embolization in the setting of large mobile thrombi. In patients where either thrombolysis is contraindicated or unsuccessful, and conventional therapies prove inadequate, surgical thrombectomy may be considered. We present a case of percutaneous endovascular extraction of a large mobile mass extending from the inferior vena cava into the right atrium using the Angiovac device,more » a venovenous bypass system designed for high-volume aspiration of undesired endovascular material. Standard endovascular methods for removal of cancer-associated thrombus, such as catheter-directed lysis, maceration, and exclusion, may prove inadequate in the setting of underlying tumor thrombus. Where conventional endovascular methods either fail or are unsuitable, endovascular thrombectomy with the Angiovac device may be a useful and safe minimally invasive alternative to open resection.« less

  14. Genuine splenic artery aneurysm rupture treated by N‐butyl cyanoacrylate and metallic coils under resuscitative endovascular balloon occlusion of the aorta

    PubMed Central

    Hagiwara, Shuichi; Miyazaki, Masaya; Kaneko, Minoru; Murata, Masato; Nakajima, Jun; Ohyama, Yoshio; Tamura, Jun'ichi; Tsushima, Yoshito; Oshima, Kiyohiro

    2016-01-01

    Case A 66 year‐old woman who presented with sudden lower abdominal pain was transferred to our emergency room. Vital signs were stable on arrival at the hospital, but immediately became unstable. Systolic/diastolic blood pressure and heart rate were 66/33 mmHg and 70 b.p.m., respectively. Computed tomography scanning showed splenic artery aneurysm rupture and extravasation. The patient was treated non‐operatively and definitively by endovascular therapy comprising resuscitative endovascular occlusion of the aorta for hemodynamic control, N‐butyl cyanoacrylate, and metallic coils as an embolization material. Outcome On admission day 3, she was enrolled in another department and admission day 54, she was discharged. Conclusion Although resuscitative endovascular occlusion of the aorta and N‐butyl cyanoacrylate is known to be effective, the use of resuscitative endovascular occlusion of the aorta with transcatheter arterial embolization and N‐butyl cyanoacrylate for non‐traumatic bleeding has not previously been reported. By combining and adapting these devices, their applications in endovascular management may be increased. PMID:29123801

  15. Reinterventions after open and endovascular AAA repair.

    PubMed

    Malina, M

    2015-04-01

    Reinterventions seem to occur more frequently after endovascular aneurysm repair than after open surgical repair and are encountered in about 20% versus 10% of the cases, respectively. However, reinterventions following endovascular repair are predominantly endoluminal and early reinterventions are more frequent after open repair. The indications for reintervention after EVAR have changed over time. The incidence and type of reintervention depends on the complexity of the primary procedure, irrespective of whether it was open or endovascular. The use of a device outside instructions for use is associated with a higher complication rate but it may nevertheless be fully justified. Advanced stent-grafts such as fenestrated and branched devices require secondary procedures more often than a standard stent-graft. Similarly, more complex open repair, e.g. a bifurcated bypass, reimplantation of visceral arteries or a redo procedure, is also associated with more reinterventions than a simple tube graft. This manuscript presents some of the most common complications of open and endovascular aortic aneurysm repair and the reinterventions they require. Many of the complications are similar with both open and endovascular techniques. Limb thrombosis, infections and endoleaks are the most frequent indications for reintervention.

  16. Endovascular treatment of a true posterior communicating artery aneurysm.

    PubMed

    Munarriz, Pablo M; Castaño-Leon, Ana M; Cepeda, Santiago; Campollo, Jorge; Alén, Jose F; Lagares, Alfonso

    2014-01-01

    Posterior communicating artery (PCoA) aneurysms are most commonly located at the junction of the internal carotid artery and the PCoA. "True" PCoA aneurysms, which originate from the PCoA itself, are rarely encountered. Most previously reported cases were treated surgically mainly before the endovascular option became available. A 53-year-old male presented with sudden onset of right hemiparesis and aphasia. Left middle cerebral artery stroke was diagnosed. Further studies revealed a 3 mm left PCoA aneurysm arising from the PCoA itself, attached to neither the internal carotid artery nor the posterior cerebral artery. Endovascular treatment was performed and the aneurysm was coiled completely. Technical advances in endovascular interventional technology have permitted an additional approach to these lesions. The possible endovascular significance of the treatment of true PCoA aneurysms is discussed.

  17. Early endovascular treatment of superior mesenteric occlusion secondary to thromboemboli.

    PubMed

    Jia, Z; Jiang, G; Tian, F; Zhao, J; Li, S; Wang, K; Wang, Y; Jiang, L; Wang, W

    2014-02-01

    To evaluate our early experience with endovascular revascularization in patients with acute thromboembolic occlusion of the superior mesenteric artery (SMA). A retrospective review was conducted of all patients who underwent endovascular revascularization for acute thromboembolic SMA occlusion from May 2005 to May 2012. Endovascular revascularization was performed using aspiration, intra-arterial thrombolysis, and adjunctive stent-placement techniques. Laparotomy was performed if the patient developed clinical signs of advanced bowel ischemia after endovascular procedure. Twenty-one patients underwent endovascular revascularization for acute thromboembolic SMA occlusion. All presented with acute-onset abdominal pain. Three patients had rebound tenderness before the procedure. Computed tomography angiography revealed complete occlusion in seven cases and incomplete occlusion in 14 cases, with no evidence of free gas or bowel necrosis. The median duration from onset of symptoms to revascularization was 8.7 ± 4.1 hours (range, 2-18 hours). Completely successful endovascular revascularization occurred in six cases (aspiration alone, 3 cases; combined aspiration and urokinase, 3 cases); partial success was achieved in 15 cases (aspiration alone, 4 cases; combined aspiration and urokinase, 10 cases; and combined aspiration, urokinase, and stent placement, 1 case). Laparotomy was required in five patients, all of whom had SMA main trunk complete occlusion and required small bowel resection. The 30-day mortality for all patients was 9.5%. During a median follow-up of 26 months, 15 patients remained asymptomatic, three patients reported occasional abdominal pain, and one patient had temporary short-bowel syndrome. Percutaneous revascularization is a promising alternative to surgery for acute SMA occlusion in selected patients who have no signs of advanced bowel ischemia. Early diagnosis followed by prompt endovascular intervention with close postprocedural monitoring is key. Laparotomy is indicated in patients who develop new or worsening signs of peritonism after endovascular procedure, particularly in those who had complete occlusion of the main trunk of the SMA. Copyright © 2013 European Society for Vascular Surgery. All rights reserved.

  18. Early and mid-term outcomes of endovascular and open surgical repair of non-dissected aortic arch aneurysm†.

    PubMed

    Hori, Daijiro; Okamura, Homare; Yamamoto, Takahiro; Nishi, Satoshi; Yuri, Koichi; Kimura, Naoyuki; Yamaguchi, Atsushi; Adachi, Hideo

    2017-06-01

    With the introduction of endovascular stent graft technology, a variety of surgical options are available for patients with aortic aneurysms. We sought to evaluate early-term and mid-term outcomes of patients undergoing endovascular and open surgical repair for non-dissected aortic arch aneurysm. Overall, 200 patients underwent treatment for isolated non-dissected aortic arch aneurysm between January 2008 and February 2016: 133 patients had open surgery and 67, endovascular repair. Early-term and mid-term outcomes were compared. Seventy percent ( n  = 47) needing endovascular repair underwent fenestrated stent graft and 30% ( n  = 20) underwent the debranched technique. Patients in the open surgery group were younger (71 vs 75 years, P  < 0.001) and had a lower prevalence of ischaemic heart disease (11% vs 35%, P  < 0.001). Intensive care unit stay (1 vs 3 days, P  < 0.001), hospital stay (11 vs 17 days, P  < 0.001) and surgical time (208 vs 390 min, P  < 0.001) were lower in the endovascular repair group than in the open surgery group. There were 3 in-hospital deaths each in the open surgery and endovascular groups (2% vs 5%, respectively, P  = 0.40). Mid-term survival ( P  < 0.001) and freedom from reintervention ( P  = 0.009) were better in the open surgery than in the endovascular repair group. No aneurysm-related deaths were observed. The propensity-matched comparison ( n  = 58) demonstrated that survival was better in the open surgery group ( P  = 0.011); no significant difference was seen in the reintervention rate ( P  = 0.28). Close follow-up for re-intervention may reduce the risk for aneurysm-related deaths and provide acceptable outcomes in patients undergoing endovascular repair. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Endovascular Therapy Is Effective and Safe for Patients With Severe Ischemic Stroke: Pooled Analysis of Interventional Management of Stroke III and Multicenter Randomized Clinical Trial of Endovascular Therapy for Acute Ischemic Stroke in the Netherlands Data.

    PubMed

    Broderick, Joseph P; Berkhemer, Olvert A; Palesch, Yuko Y; Dippel, Diederik W J; Foster, Lydia D; Roos, Yvo B W E M; van der Lugt, Aad; Tomsick, Thomas A; Majoie, Charles B L M; van Zwam, Wim H; Demchuk, Andrew M; van Oostenbrugge, Robert J; Khatri, Pooja; Lingsma, Hester F; Hill, Michael D; Roozenbeek, Bob; Jauch, Edward C; Jovin, Tudor G; Yan, Bernard; von Kummer, Rüdiger; Molina, Carlos A; Goyal, Mayank; Schonewille, Wouter J; Mazighi, Mikael; Engelter, Stefan T; Anderson, Craig S; Spilker, Judith; Carrozzella, Janice; Ryckborst, Karla J; Janis, L Scott; Simpson, Kit N

    2015-12-01

    We assessed the effect of endovascular treatment in acute ischemic stroke patients with severe neurological deficit (National Institutes of Health Stroke Scale score, ≥20) after a prespecified analysis plan. The pooled analysis of the Interventional Management of Stroke III (IMS III) and Multicenter Randomized Clinical Trial of Endovascular Therapy for Acute Ischemic Stroke in the Netherlands (MR CLEAN) trials included participants with an National Institutes of Health Stroke Scale score of ≥20 before intravenous tissue-type plasminogen activator (tPA) treatment (IMS III) or randomization (MR CLEAN) who were treated with intravenous tPA ≤3 hours of stroke onset. Our hypothesis was that participants with severe stroke randomized to endovascular therapy after intravenous tPA would have improved 90-day outcome (distribution of modified Rankin Scale scores), when compared with those who received intravenous tPA alone. Among 342 participants in the pooled analysis (194 from IMS III and 148 from MR CLEAN), an ordinal logistic regression model showed that the endovascular group had superior 90-day outcome compared with the intravenous tPA group (adjusted odds ratio, 1.78; 95% confidence interval, 1.20-2.66). In the logistic regression model of the dichotomous outcome (modified Rankin Scale score, 0-2, or functional independence), the endovascular group had superior outcomes (adjusted odds ratio, 1.97; 95% confidence interval, 1.09-3.56). Functional independence (modified Rankin Scale score, ≤2) at 90 days was 25% in the endovascular group when compared with 14% in the intravenous tPA group. Endovascular therapy after intravenous tPA within 3 hours of symptom onset improves functional outcome at 90 days after severe ischemic stroke. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00359424 (IMS III) and ISRCTN10888758 (MR CLEAN). © 2015 American Heart Association, Inc.

  20. Open versus endovascular repair of ruptured abdominal aortic aneurysms: What have we learned after more than 2 decades of ruptured endovascular aneurysm repair?

    PubMed

    Robinson, William P

    2017-12-01

    Ruptured abdominal aortic aneurysm is one of the most difficult clinical problems in surgical practice, with extraordinarily high morbidity and mortality. During the past 23 years, the literature has become replete with reports regarding ruptured endovascular aneurysm repair. A variety of study designs and databases have been utilized to compare ruptured endovascular aneurysm repair and open surgical repair for ruptured abdominal aortic aneurysm and studies of various designs from different databases have yielded vastly different conclusions. It therefore remains controversial whether ruptured endovascular aneurysm repair improves outcomes after ruptured abdominal aortic aneurysm in comparison to open surgical repair. The purpose of this article is to review the best available evidence comparing ruptured endovascular aneurysm repair and open surgical repair of ruptured abdominal aortic aneurysm, including single institution and multi-institutional retrospective observational studies, large national population-based studies, large national registries of prospectively collected data, and randomized controlled clinical trials. This article will analyze the study designs and databases utilized with their attendant strengths and weaknesses to understand the sometimes vastly different conclusions the studies have reached. This article will attempt to integrate the data to distill some of the lessons that have been learned regarding ruptured endovascular aneurysm repair and identify ongoing needs in this field. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Ruptured Petrous Carotid Pseudoaneurysm Due to Tuberculous Otitis: Endovascular Treatment

    PubMed Central

    Yagci, A.B.; Ardiç, F.N.; Oran, I.; Bir, F.; Karabulut, N.

    2006-01-01

    Summary We report the imaging findings and endovascular treatment in an unusual case of petrous internal carotid artery pseudoaneurysm due to primary tuberculous otitis. The aneurysm was recognized and ruptured during a surgical intervention for otitis. Successful endovascular treatment of the aneurysm was performed by occlusion of the parent vessel using detachable balloon and coils. PMID:20569552

  2. Ruptured petrous carotid pseudoaneurysm due to tuberculous otitis: endovascular treatment.

    PubMed

    Yagci, A B; Ardiç, F N; Oran, I; Bir, F; Karabulut, N

    2006-03-15

    We report the imaging findings and endovascular treatment in an unusual case of petrous internal carotid artery pseudoaneurysm due to primary tuberculous otitis. The aneurysm was recognized and ruptured during a surgical intervention for otitis. Successful endovascular treatment of the aneurysm was performed by occlusion of the parent vessel using detachable balloon and coils.

  3. Endovascular Device Testing with Particle Image Velocimetry Enhances Undergraduate Biomedical Engineering Education

    ERIC Educational Resources Information Center

    Nair, Priya; Ankeny, Casey J.; Ryan, Justin; Okcay, Murat; Frakes, David H.

    2016-01-01

    We investigated the use of a new system, HemoFlow™, which utilizes state of the art technologies such as particle image velocimetry to test endovascular devices as part of an undergraduate biomedical engineering curriculum. Students deployed an endovascular stent into an anatomical model of a cerebral aneurysm and measured intra-aneurysmal flow…

  4. Strategy of endovascular versus open repair for patients with clinical diagnosis of ruptured abdominal aortic aneurysm: the IMPROVE RCT.

    PubMed

    Ulug, Pinar; Hinchliffe, Robert J; Sweeting, Michael J; Gomes, Manuel; Thompson, Matthew T; Thompson, Simon G; Grieve, Richard J; Ashleigh, Raymond; Greenhalgh, Roger M; Powell, Janet T

    2018-05-01

    Ruptured abdominal aortic aneurysm (AAA) is a common vascular emergency. The mortality from emergency endovascular repair may be much lower than the 40-50% reported for open surgery. To assess whether or not a strategy of endovascular repair compared with open repair reduces 30-day and mid-term mortality (including costs and cost-effectiveness) among patients with a suspected ruptured AAA. Randomised controlled trial, with computer-generated telephone randomisation of participants in a 1 : 1 ratio, using variable block size, stratified by centre and without blinding. Vascular centres in the UK ( n  = 29) and Canada ( n  = 1) between 2009 and 2013. A total of 613 eligible participants (480 men) with a ruptured aneurysm, clinically diagnosed at the trial centre. A total of 316 participants were randomised to the endovascular strategy group (immediate computerised tomography followed by endovascular repair if anatomically suitable or, if not suitable, open repair) and 297 were randomised to the open repair group (computerised tomography optional). The primary outcome measure was 30-day mortality, with 30-day reinterventions, costs and disposal as early secondary outcome measures. Later outcome measures included 1- and 3-year mortality, reinterventions, quality of life (QoL) and cost-effectiveness. The 30-day mortality was 35.4% in the endovascular strategy group and 37.4% in the open repair group [odds ratio (OR) 0.92, 95% confidence interval (CI) 0.66 to 1.28; p  = 0.62, and, after adjustment for age, sex and Hardman index, OR 0.94, 95% CI 0.67 to 1.33]. The endovascular strategy appeared to be more effective in women than in men (interaction test p  = 0.02). More discharges in the endovascular strategy group (94%) than in the open repair group (77%) were directly to home ( p  < 0.001). Average 30-day costs were similar between groups, with the mean difference in costs being -£1186 (95% CI -£2997 to £625), favouring the endovascular strategy group. After 1 year, survival and reintervention rates were similar in the two groups, QoL (at both 3 and 12 months) was higher in the endovascular strategy group and the mean cost difference was -£2329 (95% CI -£5489 to £922). At 3 years, mortality was 48% and 56% in the endovascular strategy group and open repair group, respectively (OR 0.73, 95% CI 0.53 to 1.00; p  = 0.053), with a stronger benefit for the endovascular strategy in the subgroup of 502 participants in whom repair was started for a proven rupture (OR 0.62, 95% CI 0.43 to 0.89; p  = 0.009), whereas aneurysm-related reintervention rates were non-significantly higher in this group. At 3 years, considering all participants, there was a mean difference of 0.174 quality-adjusted life-years (QALYs) (95% CI 0.002 to 0.353 QALYs) and, among the endovascular strategy group, a cost difference of -£2605 (95% CI -£5966 to £702), leading to 88% of estimates in the cost-effectiveness plane being in the quadrant showing the endovascular strategy to be 'dominant'. Because of the pragmatic design of this trial, 33 participants in the endovascular strategy group and 26 in the open repair group breached randomisation allocation. The endovascular strategy was not associated with a significant reduction in either 30-day mortality or cost but was associated with faster participant recovery. By 3 years, the endovascular strategy showed a survival and QALY gain and was highly likely to be cost-effective. Future research could include improving resuscitation for older persons with circulatory collapse, the impact of local anaesthesia and emergency consent procedures. Current Controlled Trials ISRCTN48334791 and NCT00746122. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 22, No. 31. See the NIHR Journals Library website for further project information.

  5. Cost-effectiveness analysis of endovascular versus neurosurgical treatment for ruptured intracranial aneurysms in the United States

    PubMed Central

    Maud, Alberto; Lakshminarayan, Kamakshi; Suri, M. Fareed K.; Vazquez, Gabriela; Lanzino, Giuseppe; Qureshi, Adnan I.

    2009-01-01

    Object The results of the International Subarachnoid Aneurysm Trial (ISAT) demonstrated lower rates of death and disability with endovascular treatment (coiling) than with open surgery (clipping) to secure the ruptured intracranial aneurysm. However, cost-effectiveness may not be favorable because of the greater need for follow-up cerebral angiograms and additional follow-up treatment with endovascular methods. In this study, the authors’ goal was to compare the cost-effectiveness of endovascular and neurosurgical treatments in patients with ruptured intracranial aneurysms who were eligible to undergo either type of treatment. Methods Clinical data (age, sex, frequency of retreatment, and rebleeding) and quality of life values were obtained from the ISAT. Total cost included those associated with disability, hospitalization, retreatment, and rebleeding. Cost estimates were derived from the Premier Perspective Comparative Database, data from long-term care in stroke patients, and relevant literature. Incremental cost-effectiveness ratios (ICERs) were estimated during a 1-year period. Parametric bootstrapping was used to determine the uncertainty of the estimates. Results The median estimated costs of endovascular and neurosurgical treatments (in US dollars) were $45,493 (95th percentile range $44,693–$46,365) and $41,769 (95th percentile range $41,094–$42,518), respectively. The overall quality-adjusted life years (QALY) in the endovascular group was 0.69, and for the neurosurgical group it was 0.64. The cost per QALY in the endovascular group was $65,424 (95th percentile range $64,178–$66,772), and in the neurosurgical group it was $64,824 (95th percentile range $63,679–$66,086). The median estimated ICER at 1 year for endovascular treatment versus neurosurgical treatment was $72,872 (95th percentile range $50,344–$98,335) per QALY gained. Given that most postprocedure angiograms and additional treatments occurred in the 1st year and the 1-year disability status is unlikely to change in the future, ICER for endovascular treatment will progressively decrease over time. Conclusions Using outcome and economic data obtained in the US at 1 year after the procedure, endovascular treatment is more costly but is associated with better outcomes than the neurosurgical alternative among patients with ruptured intracranial aneurysms who are eligible to undergo either procedure. With accrual of additional years with a better outcome status, the ICER for endovascular coiling would be expected to progressively decrease and eventually reverse. PMID:19199452

  6. Endovascular treatment of a true posterior communicating artery aneurysm

    PubMed Central

    Munarriz, Pablo M.; Castaño-Leon, Ana M.; Cepeda, Santiago; Campollo, Jorge; Alén, Jose F.; Lagares, Alfonso

    2014-01-01

    Background: Posterior communicating artery (PCoA) aneurysms are most commonly located at the junction of the internal carotid artery and the PCoA. “True” PCoA aneurysms, which originate from the PCoA itself, are rarely encountered. Most previously reported cases were treated surgically mainly before the endovascular option became available. Case Description: A 53-year-old male presented with sudden onset of right hemiparesis and aphasia. Left middle cerebral artery stroke was diagnosed. Further studies revealed a 3 mm left PCoA aneurysm arising from the PCoA itself, attached to neither the internal carotid artery nor the posterior cerebral artery. Endovascular treatment was performed and the aneurysm was coiled completely. Conclusion: Technical advances in endovascular interventional technology have permitted an additional approach to these lesions. The possible endovascular significance of the treatment of true PCoA aneurysms is discussed. PMID:25422786

  7. Modern radiosurgical and endovascular classification schemes for brain arteriovenous malformations.

    PubMed

    Tayebi Meybodi, Ali; Lawton, Michael T

    2018-05-04

    Stereotactic radiosurgery (SRS) and endovascular techniques are commonly used for treating brain arteriovenous malformations (bAVMs). They are usually used as ancillary techniques to microsurgery but may also be used as solitary treatment options. Careful patient selection requires a clear estimate of the treatment efficacy and complication rates for the individual patient. As such, classification schemes are an essential part of patient selection paradigm for each treatment modality. While the Spetzler-Martin grading system and its subsequent modifications are commonly used for microsurgical outcome prediction for bAVMs, the same system(s) may not be easily applicable to SRS and endovascular therapy. Several radiosurgical- and endovascular-based grading scales have been proposed for bAVMs. However, a comprehensive review of these systems including a discussion on their relative advantages and disadvantages is missing. This paper is dedicated to modern classification schemes designed for SRS and endovascular techniques.

  8. Development of stroke-induced quadriplegia after endovascular repair of blunt aortic injury pseudoaneurysm.

    PubMed

    Amoudi, Abdullah S; Merdad, Anas A; Makhdoom, Ahmed Q; Jamjoom, Reda A

    2015-01-01

    Endovascular repair of blunt aortic injury is now a first-line approach in management. This can warrant coverage of the left subclavian artery (LSA), which could lead to posterior strokes. In this case report, we present a severe complication of endovascular repair of a traumatic aortic aneurysm. A 53-year-old man presented with blunt aortic injury, endovascular repair was carried out where the left subclavian artery was covered. The intervention had a 100% technical success. Twelve hours later, he was discovered to have quadriplegia, a CT scan showed a large left cerebellar infarction extending to the medulla oblongata and proximal spinal cord. Strokes complicate 3% of thoracic endovascular aortic repairs, 80% of those strokes occur in patients who had their LSA`s covered. Most patients however, tolerate the coverage. Although our patient had a dominant right vertebral artery, and lacked risks for these strokes, he developed an extensive stroke that left him quadriplegic.

  9. Clipping in Awake Surgery as End-Stage in a Complex Internal Carotid Artery Aneurysm After Failure of Multimodal Endovascular and Extracranial-Intracranial Bypass Treatment.

    PubMed

    Cannizzaro, Delia; Peschillo, Simone; Mancarella, Cristina; La Pira, Biagia; Rastelli, Emanuela; Passacantilli, Emiliano; Santoro, Antonio

    2017-06-01

    Intracranial carotid artery aneurysm can be treated via microsurgical or endovascular techniques. The optimal planning is the result of the careful patient selection through clinical, anatomic, and angiographic analysis. We present a case of ruptured internal carotid artery (ICA) aneurysm that became a complex aneurysm after failure of multi-endovascular and surgery treatment. We describe complete trapping in awake craniotomy after failure of coiling, stenting, and bypassing. ICA aneurysms could become complex aneurysms following multi-treatment failure. Endovascular approaches to treat ICA aneurysms include coiling, stenting, flow diverter stenting, and stenting-assisted coiling technique. The role of surgery remains relevant. To avoid severe neurologic deficits, recurrence, and the need of retreatment, a multidisciplinary discussion with experienced endovascular and vascular neurosurgeons is mandatory in such complex cases. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  10. Endovascular management of iatrogenic cervical internal carotid artery pseudoaneurysm in a 9-year-old child: Case report and literature review.

    PubMed

    Pinzón, Martín; Lobelo, Nelson Oswaldo; Rodríguez, María Claudia; Villamor, Perla; Otoya, Ana María

    2017-04-01

    Extracranial internal carotid artery (ICA) pseudoaneurysms are uncommon in the pediatric population and are usually secondary to direct trauma to the vessel. Treatment options include surgery (ligation), anticoagulation therapy and endovascular treatment. Endovascular covered stents have shown good results in adult populations, resulting in occlusion of the aneurysm and preservation of the artery without significant complications. However, there have been only limited reports in the literature reporting endovascular carotid stent placement in the pediatric population. We report a case of a 9-year-old boy patient, who developed a cervical ICA pseudoaneurysm after a parapharyngeal tumor resection. He was successfully treated by primary endovascular covered stent placement. During a follow-up of 6 months the patient has been asymptomatic, without any adverse event. Additionally, a literature review is done. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. The evolution of endovascular electroencephalography: historical perspective and future applications.

    PubMed

    Sefcik, Roberta K; Opie, Nicholas L; John, Sam E; Kellner, Christopher P; Mocco, J; Oxley, Thomas J

    2016-05-01

    Current standard practice requires an invasive approach to the recording of electroencephalography (EEG) for epilepsy surgery, deep brain stimulation (DBS), and brain-machine interfaces (BMIs). The development of endovascular techniques offers a minimally invasive route to recording EEG from deep brain structures. This historical perspective aims to describe the technical progress in endovascular EEG by reviewing the first endovascular recordings made using a wire electrode, which was followed by the development of nanowire and catheter recordings and, finally, the most recent progress in stent-electrode recordings. The technical progress in device technology over time and the development of the ability to record chronic intravenous EEG from electrode arrays is described. Future applications for the use of endovascular EEG in the preoperative and operative management of epilepsy surgery are then discussed, followed by the possibility of the technique's future application in minimally invasive operative approaches to DBS and BMI.

  12. Intensive Care Management of Thoracic Aortic Surgical Patients, Including Thoracic and Infradiaphragmatic Endovascular Repair (EVAR/TEVAR).

    PubMed

    Cole, Sheela Pai

    2015-12-01

    The patient with thoracic aortic disease can present for open or endovascular repair. Thoracic endovascular aortic repair (TEVAR) has emerged as a minimally invasive option for a multitude of aortic pathology, including dissections, aneurysms, traumatic injuries, and ulcers. Postoperative management of these patients depends on the extent of procedure, whether it was open or endovascular, and, finally, on the preoperative comorbidities present. While procedural success has catapulted TEVAR to popularity, midterm results have been mixed. Additionally, periprocedural complications such as paraplegia and renal failure remain a significant morbidity in these patients. © The Author(s) 2015.

  13. Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms.

    PubMed

    Attigah, Nicolas; Oikonomou, Kyriakos; Hinz, Ulf; Knoch, Thomas; Demirel, Serdar; Verhoeven, Eric; Böckler, Dittmar

    2016-01-01

    The purpose of this study was to evaluate the radiation exposure of vascular surgeons' eye lens and fingers during complex endovascular procedures in modern hybrid operating rooms. Prospective, nonrandomized multicenter study design. One hundred seventy-one consecutive patients (138 male; median age, 72.5 years [interquartile range, 65-77 years]) underwent an endovascular procedure in a hybrid operating room between March 2012 and July 2013 in two vascular centers. The dose-area product (DAP), fluoroscopy time, operating time, and amount of contrast dye were registered prospectively. For radiation dose recordings, single-use dosimeters were attached at eye level and to the ring finger of the hand next to the radiation field of the operator for each endovascular procedure. Dose recordings were evaluated by an independent institution. Before the study, precursory investigations were obtained to simulate the radiation dose to eye lens and fingers with an Alderson phantome (RSD, Long Beach, Calif). Interventions were classified into six treatment categories: endovascular repair of infrarenal abdominal aneurysm (n = 65), thoracic endovascular aortic repair (n = 32), branched endovascular aortic repair for thoracoabdominal aneurysms (n = 17), fenestrated endovascular aortic repair for complex abdominal aortic aneurysm, (n = 25), iliac branched device (n = 8), and peripheral interventions (n = 24). There was a significant correlation in DAP between both lens (P < .01; r = 0.55) and finger (P < .01; r = 0.56) doses. The estimated fluoroscopy time to reach a radiation threshold of 20 mSv/y was 1404.10 minutes (90% confidence limit, 1160, 1650 minutes). According to correlation of the lens dose with the DAP an estimated cumulative DAP of 932,000 mGy/m(2) (90% confidence limit, 822,000, 1,039,000) would be critical for a threshold of 20 mSv/y for the eyes. Radiation protection is a serious issue for vascular surgeons because most complex endovascular procedures are delivering measurable radiation to the eyes. With the correlation of the DAP obtained in standard endovascular procedures a critical threshold of 20 mSv/y to the eyes can be predicted and thus an estimate of a potential harmful exposure to the eyes can be obtained. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  14. Impact of Smartphone Applications on Timing of Endovascular Therapy for Ischemic Stroke: A Preliminary Study.

    PubMed

    Alotaibi, Naif M; Sarzetto, Francesca; Guha, Daipayan; Lu, Michael; Bodo, Andre; Gupta, Shaurya; Dyer, Erin; Howard, Peter; da Costa, Leodante; Swartz, Richard H; Boyle, Karl; Nathens, Avery B; Yang, Victor X D

    2017-11-01

    The metrics of imaging-to-puncture and imaging-to-reperfusion were recently found to be associated with the clinical outcomes of endovascular thrombectomy for acute ischemic stroke. However, measures for improving workflow within hospitals to achieve better timing results are largely unexplored for endovascular therapy. The aim of this study was to examine our experience with a novel smartphone application developed in house to improve our timing metrics for endovascular treatment. We developed an encrypted smartphone application connecting all stroke team members to expedite conversations and to provide synchronized real-time updates on the time window from stroke onset to imaging and to puncture. The effects of the application on the timing of endovascular therapy were evaluated with a secondary analysis of our single-center cohort. Our primary outcome was imaging-to-puncture time. We assessed the outcomes with nonparametric tests of statistical significance. Forty-five patients met our criteria for analysis among 66 consecutive patients with acute ischemic stroke who received endovascular therapy at our institution. After the implementation of the smartphone application, imaging-to-puncture time was significantly reduced (preapplication median time, 127 minutes; postapplication time, 69 minutes; P < 0.001). Puncture-to-reperfusion time was not affected by the application use (42 minutes vs. 36 minutes). The use of smartphone applications may reduce treatment times for endovascular therapy in acute ischemic stroke. Further studies are needed to confirm our findings. Copyright © 2017. Published by Elsevier Inc.

  15. Prophylactic antibiotics for percutaneous endovascular procedures.

    PubMed

    Greaves, N S; Katsogridakis, E; Faris, B; Murray, D

    2017-04-01

    Percutaneous endovascular techniques are used increasingly in the vascular armamentarium. Commonly performed as day case procedures under local anaesthetic, they are suited to the highly co-morbid vascular patient population. Furthermore, technological advances have resulted in ever improving outcomes for aneurysmal and occlusive disease. Endovascular procedures such as endovascular aneurysm repair or iliac artery stenting are traditionally associated with reduced infectious complications compared to equivalent open techniques. However, when they do occur, they are equally devastating and often associated with limb loss or death since the only effective treatment is removal of all infected material. The use of prophylactic antibiotics to reduce infectious complications in open surgery has a strong evidence base, but there is no equivalent data for percutaneous endovascular procedures. The Society of Interventional Radiology published formal guidelines for adult antibiotic prophylaxis in 2010. Based on relatively poor quality studies, they nevertheless represent the first official guidance in the field and stress the need for large randomised controlled trials to further guide the debate. Broadly, the benefits of reduced infectious complications must be balanced against the fiscal cost of increased antimicrobial usage, promotion of multi-drug resistant organisms and patient side-effect profiles. The number needed to treat to prevent one infection is high yet without it a small but significant number of patients will suffer serious adverse outcomes secondary to infection of endovascular prostheses. This review article aims to summarise the evidence around the use of prophylactic antibiotics in percutaneous endovascular procedures.

  16. Endovascular Management of Delayed Complete Graft Thrombosis After Endovascular Aneurysm Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thurley, Peter D., E-mail: pthurley@doctors.org.u; Glasby, Michael J.; Pollock, John G.

    2010-08-15

    Graft thrombosis rates after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms vary widely in published series. When thrombosis does occur, it usually involves a single limb and occurs within 3 months of stent-graft insertion. If the entire endoprosthesis is thrombosed, treatment may be challenging because femoro-femoral crossover graft insertion is not an option and a greater volume of thrombus is present, thus making thrombolysis more difficult. We present two cases of delayed thrombosis after EVAR involving the entire stent-graft. These were successfully treated by a combined surgical and endovascular technique, and patency has been maintained in both cases tomore » date.« less

  17. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    PubMed

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P < 0.01). The radial force of the thoracic stents was greater than that of all three endovascular stents (P < 0.01). Differences in radial force depend on types of stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  18. Moving into the paravisceral aorta using fenestrated and branched endografts.

    PubMed

    Farber, Mark A; Vallabhaneni, Raghuveer

    2012-12-01

    When one compares the potential advantages of endovascular aortic repair with respect to traditional open repair, it would seem logical that extension into the paravisceral aorta would be easily justified, given the complexity of open aortic repair and its associated complications. Eight years have transpired between trial initiation and Food and Drug Administration approval of the first fenestrated device in the United States for the treatment of juxtarenal aneurysms. While there are only a few centers in the United States with substantial experience performing fenestrated and branched endovascular aortic repair, there is a diverse experience outside the United States that has been gained over the past decade. It is through the experience of these centers that the technical and procedural complexities of complex endovascular aortic repair has been solved and provide the foundation that has allowed aortic specialists to move endovascular therapy into the paravisceral aorta with fenestrated and branched endovascular aortic repairs. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Resuscitative Endovascular Balloon Occlusion of the Aorta: A Bridge to Flight Survival.

    PubMed

    Goforth, Carl; Bradley, Matthew; Pineda, Benilani; See, Suzanne; Pasley, Jason

    2018-04-01

    Trauma endures as the leading cause of death worldwide, and most deaths occur in the first 24 hours after initial injury as a result of hemorrhage. Historically, about 90% of battlefield deaths occur before the injured person arrives at a theater hospital, and most are due to noncompressible hemorrhage of the torso. Resuscitative endovascular balloon occlusion of the aorta is an evolving technique to quickly place a balloon into the thoracic or abdominal aorta to efficiently block blood flow to distal circulation. Maneuvers, such as resuscitative endovascular balloon occlusion of the aorta, to control endovascular hemorrhage offer a potential intervention to control noncompressible hemorrhage. This technique can be performed percutaneously or open in prehospital environments to restore hemodynamic functions and serve as a survival bridge until the patient is delivered to a treatment facility for definitive surgical hemostasis. This article describes the indications, complications, and application of resuscitative endovascular balloon occlusion of the aorta to military and civilian aeromedical transport. ©2018 American Association of Critical-Care Nurses.

  20. Development of stroke-induced quadriplegia after endovascular repair of blunt aortic injury pseudoaneurysm

    PubMed Central

    Amoudi, Abdullah S.; Merdad, Anas A.; Makhdoom, Ahmed Q.; Jamjoom, Reda A.

    2015-01-01

    Endovascular repair of blunt aortic injury is now a first-line approach in management. This can warrant coverage of the left subclavian artery (LSA), which could lead to posterior strokes. In this case report, we present a severe complication of endovascular repair of a traumatic aortic aneurysm. A 53-year-old man presented with blunt aortic injury, endovascular repair was carried out where the left subclavian artery was covered. The intervention had a 100% technical success. Twelve hours later, he was discovered to have quadriplegia, a CT scan showed a large left cerebellar infarction extending to the medulla oblongata and proximal spinal cord. Strokes complicate 3% of thoracic endovascular aortic repairs, 80% of those strokes occur in patients who had their LSA’s covered. Most patients however, tolerate the coverage. Although our patient had a dominant right vertebral artery, and lacked risks for these strokes, he developed an extensive stroke that left him quadriplegic. PMID:25630782

  1. Endovascular surgery for peripheral arterial occlusive disease. A critical review.

    PubMed Central

    Ahn, S S; Eton, D; Moore, W S

    1992-01-01

    Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents. This field can be defined as a diagnostic and therapeutic discipline that uses catheter-based systems to treat vascular disease. As such, it integrates the subspecialties of vascular surgery, interventional radiology, interventional cardiology, and biomedical engineering for the common purpose of improving arterial hemodynamics. Endovascular surgery offers many potential benefits: long incisions are replaced with a puncture wound, the need for postoperative intensive care is significantly reduced, major cardiac and pulmonary complications from general anesthesia are side stepped, and the dollar savings could be dramatic as the need for intensive care unit and in-hospital stay diminishes. Despite these technological advancements, endovascular surgery is still in its infancy and currently has limited applications. This review provides an updated summary of endovascular surgery today and addresses some of the obstacles still preventing its widespread use. PMID:1385944

  2. Endovascular management of sigmoid sinus dural arteriovenous fistula associated with sinus stenosis in an infant.

    PubMed

    Cohen, José E; Gomori, John M; Benifla, Moni; Itshayek, Eyal; Moscovici, Samuel

    2013-01-01

    A 4-month-old female presented with a dural arteriovenous fistula (DAVF), which was successfully managed using endovascular techniques. There are very few case series reporting DAVF in infants younger than 12 months and, to our knowledge, only 60 pediatric patients with DAVF have been reported to date. Although most DAVF have a benign course, they can result in life-threatening hemorrhage. Endovascular therapies are usually indicated in the management of these neurosurgical vascular malformations. Endovascular therapy of DAVF in neonatal patients presents some major issues. Gaining arterial access may be problematic in femoral arteries too small for the introduction of a sizeable guiding catheter. The volumes of contrast and infused fluids must be carefully monitored to prevent fluid overload. Radiation exposure should be restricted as far as possible. This report contributes to the limited body of evidence on neonatal DAVF and its endovascular management. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Delayed pan-hypopituitarism as a complication following endovascular treatment of bilateral internal carotid artery aneurysms. A case report and review.

    PubMed

    Hall, Jonathan; Caputo, Carmela; Chung, Carlos; Holt, Michael; Wang, Yi Yuen

    2015-04-01

    Pan-hypopituitarism has been reported in patients who are subsequently found to have a cerebral aneurysm and there have been reports of pituitary dysfunction immediately following both surgical and endovascular treatment. The authors report a rare case of delayed pan-hypopituitarism following endovascular treatment of bilateral internal carotid artery aneurysms with coil embolisation and flow-diverting stents.

  4. Endovascular Electrodes for Electrical Stimulation of Blood Vessels for Vasoconstriction - a Finite Element Simulation Study

    NASA Astrophysics Data System (ADS)

    Kezurer, Noa; Farah, Nairouz; Mandel, Yossi

    2016-08-01

    Hemorrhagic shock accounts for 30-40 percent of trauma mortality, as bleeding may sometimes be hard to control. Application of short electrical pulses on blood vessels was recently shown to elicit robust vasoconstriction and reduction of blood loss following vascular injury. In this study we present a novel approach for vasoconstriction based on endovascular application of electrical pulses for situations where access to the vessel is limited. In addition to ease of access, we hypothesize that this novel approach will result in a localized and efficient vasoconstriction. Using computer modeling (COMSOL Multiphysics, Electric Currents Module), we studied the effect of endovascular pulsed electrical treatment on abdominal aorta of pigs, and compared the efficiency of different electrodes configurations on the electric field amplitude, homogeneity and locality when applied on a blood vessel wall. Results reveal that the optimal configuration is the endovascular approach where four electrodes are used, spaced 13 mm apart. Furthermore, computer based temperature investigations (bio-heat model, COMSOL Multiphysics) show that the maximum expected temperature rise is of 1.2 degrees; highlighting the safety of the four endovascular electrodes configuration. These results can aid in planning the application of endovascular pulsed electrical treatment as an efficient and safe vasoconstriction approach.

  5. Endovascular repair of ruptured abdominal aortic aneurysms: experience in a community hospital.

    PubMed

    Davit, Flavia E; Cole, Theresa; Helling, Thomas; Tretter, James

    2007-11-01

    The endovascular technique has been recently used as an alternative procedure for selected patients with ruptured abdominal aortic aneurysm (RAAA) as a result of the potential for decreasing morbidity, mortality, and recovery time. We examined our institution's results with endovascular repair of RAAA. Between July 2005 and April 2006, four patients underwent endovascular repair of infrarenal RAAA. We performed a retrospective analysis of our comorbidities, operation time, length of intensive care unit and hospital stay, morbidity and mortality, blood transfusions, and secondary interventions on these patients at our institution. The median age was 73.2 years (range, 66-82 years); 75 per cent were male and 25 per cent were female. Mean operating time was 90 minutes. We had no operative or postoperative mortalities. Five complications occurred in three patients. These included acute renal failure, common femoral artery intimal dissection, graft thrombosis of the iliac limb, ischemic colitis, and chronic obstructive pulmonary disease exacerbation. Endovascular repair of RAAA by an endovascular team is feasible in the community hospital setting. Our limited number of patients in this study does not allow us to compare it directly with results from the standard open procedure. A larger, multicenter study may eventually show this method to be helpful in patients who require repair of RAAA.

  6. Endovascular Electrodes for Electrical Stimulation of Blood Vessels for Vasoconstriction – a Finite Element Simulation Study

    PubMed Central

    Kezurer, Noa; Farah, Nairouz; Mandel, Yossi

    2016-01-01

    Hemorrhagic shock accounts for 30–40 percent of trauma mortality, as bleeding may sometimes be hard to control. Application of short electrical pulses on blood vessels was recently shown to elicit robust vasoconstriction and reduction of blood loss following vascular injury. In this study we present a novel approach for vasoconstriction based on endovascular application of electrical pulses for situations where access to the vessel is limited. In addition to ease of access, we hypothesize that this novel approach will result in a localized and efficient vasoconstriction. Using computer modeling (COMSOL Multiphysics, Electric Currents Module), we studied the effect of endovascular pulsed electrical treatment on abdominal aorta of pigs, and compared the efficiency of different electrodes configurations on the electric field amplitude, homogeneity and locality when applied on a blood vessel wall. Results reveal that the optimal configuration is the endovascular approach where four electrodes are used, spaced 13 mm apart. Furthermore, computer based temperature investigations (bio-heat model, COMSOL Multiphysics) show that the maximum expected temperature rise is of 1.2 degrees; highlighting the safety of the four endovascular electrodes configuration. These results can aid in planning the application of endovascular pulsed electrical treatment as an efficient and safe vasoconstriction approach. PMID:27534438

  7. Current Status of Endovascular Treatment for Vasospasm following Subarachnoid Hemorrhage: Analysis of JR-NET2

    PubMed Central

    HAYASHI, Kentaro; HIRAO, Tomohito; SAKAI, Nobuyuki; NAGATA, Izumi

    2014-01-01

    Endovascular treatments are employed for cerebral vasospasm following subarachnoid hemorrhage, which is not responded to the medical treatments. However, the effect or complication of the treatments is not known well. Here, we analyzed the data of Japanese Registry of Neuroendovascular Therapy 2 (JRNET2) and revealed current status of the endovascular treatment for the cerebral vasospasm. JR-NET2 is conducted from January 1, 2007 to December 31, 2009. Information on the clinical status, imaging studies, treatment methods, the results of treatment, and status 30 days later were recorded. Totally 645 treatments for 480 patients (mean age, 59.4 years; 72.7% woman) were included. Factors related to the neurological improvement and treatment related complications were statistically analyzed. Treatments for ruptured cerebral aneurysm were direct surgery for 366 cases and endovascular treatment for 253 cases. The timing of the endovascular treatment for the cerebral vasospasm was within 3 hours in 209 cases, 3–6 hours in 158 cases, and more than 6 hours in 158 cases. Intra-arterial vasodilator was employed for the 495 cases and percutaneous transluminal angioplasty for 140 cases. Neurological improvement was observed in 372 cases and radiological improvement was seen in 623 cases. The treatment related complication occurred in 20 cases (3.1%), including 6 cases of intracranial hemorrhage, 5 cases of cerebral ischemia, a case of puncture site trouble, and 8 cases of others. Statistical analysis showed early treatment was related to the neurological improvement. Current status of endovascular treatment for cerebral vasospasm was revealed. Endovascular treatment was effective for vasospasm especially was performed early. PMID:24257541

  8. Current status of endovascular treatment for vasospasm following subarachnoid hemorrhage: analysis of JR-NET2.

    PubMed

    Hayashi, Kentaro; Hirao, Tomohito; Sakai, Nobuyuki; Nagata, Izumi

    2014-01-01

    Endovascular treatments are employed for cerebral vasospasm following subarachnoid hemorrhage, which is not responded to the medical treatments. However, the effect or complication of the treatments is not known well. Here, we analyzed the data of Japanese Registry of Neuroendovascular Therapy 2 (JR-NET2) and revealed current status of the endovascular treatment for the cerebral vasospasm. JR-NET2 is conducted from January 1, 2007 to December 31, 2009. Information on the clinical status, imaging studies, treatment methods, the results of treatment, and status 30 days later were recorded. Totally 645 treatments for 480 patients (mean age, 59.4 years; 72.7% woman) were included. Factors related to the neurological improvement and treatment related complications were statistically analyzed. Treatments for ruptured cerebral aneurysm were direct surgery for 366 cases and endovascular treatment for 253 cases. The timing of the endovascular treatment for the cerebral vasospasm was within 3 hours in 209 cases, 3-6 hours in 158 cases, and more than 6 hours in 158 cases. Intra-arterial vasodilator was employed for the 495 cases and percutaneous transluminal angioplasty for 140 cases. Neurological improvement was observed in 372 cases and radiological improvement was seen in 623 cases. The treatment related complication occurred in 20 cases (3.1%), including 6 cases of intracranial hemorrhage, 5 cases of cerebral ischemia, a case of puncture site trouble, and 8 cases of others. Statistical analysis showed early treatment was related to the neurological improvement. Current status of endovascular treatment for cerebral vasospasm was revealed. Endovascular treatment was effective for vasospasm especially was performed early.

  9. Current Status of Endovascular Treatment for Vasospasm following Subarachnoid Hemorrhage: Analysis of JR-NET2.

    PubMed

    Hayashi, Kentaro; Hirao, Tomohito; Sakai, Nobuyuki; Nagata, Izumi

    2014-01-01

    Endovascular treatments are employed for cerebral vasospasm following subarachnoid hemorrhage, which is not responded to the medical treatments. However, the effect or complication of the treatments is not known well. Here, we analyzed the data of Japanese Registry of Neuroendovascular Therapy 2 (JR-NET2) and revealed current status of the endovascular treatment for the cerebral vasospasm. JR-NET2 is conducted from January 1, 2007 to December 31, 2009. Information on the clinical status, imaging studies, treatment methods, the results of treatment, and status 30 days later were recorded. Totally 645 treatments for 480 patients (mean age, 59.4 years; 72.7% woman) were included. Factors related to the neurological improvement and treatment related complications were statistically analyzed. Treatments for ruptured cerebral aneurysm were direct surgery for 366 cases and endovascular treatment for 253 cases. The timing of the endovascular treatment for the cerebral vasospasm was within 3 hours in 209 cases, 3–6 hours in 158 cases, and more than 6 hours in 158 cases. Intra-arterial vasodilator was employed for the 495 cases and percutaneous transluminal angioplasty for 140 cases. Neurological improvement was observed in 372 cases and radiological improvement was seen in 623 cases. The treatment related complication occurred in 20 cases (3.1%), including 6 cases of intracranial hemorrhage, 5 cases of cerebral ischemia, a case of puncture site trouble, and 8 cases of others. Statistical analysis showed early treatment was related to the neurological improvement. Current status of endovascular treatment for cerebral vasospasm was revealed. Endovascular treatment was effective for vasospasm especially was performed early.

  10. Endovascular Therapy is Effective and Safe for Patients with Severe Ischemic Stroke: Pooled Analysis of IMS III and MR CLEAN Data

    PubMed Central

    Broderick, Joseph P.; Berkhemer, Olvert A.; Palesch, Yuko Y.; Dippel, Diederik W.J.; Foster, Lydia D.; Roos, Yvo B.W.E.M.; van der Lugt, Aad; Tomsick, Thomas A.; Majoie, Charles B.L.M.; van Zwam, Wim H.; Demchuk, Andrew M.; van Oostenbrugge, Robert J.; Khatri, Pooja; Lingsma, Hester F.; Hill, Michael D.; Roozenbeek, Bob; Jauch, Edward C.; Jovin, Tudor G.; Yan, Bernard; von Kummer, Rüdiger; Molina, Carlos A.; Goyal, Mayank; Schonewille, Wouter J.; Mazighi, Mikael; Engelter, Stefan T.; Anderson, Craig S.; Spilker, Judith; Carrozzella, Janice; Ryckborst, Karla J.; Janis, L. Scott; Simpson, Kit

    2015-01-01

    Background and Purpose We assessed the effect of endovascular treatment in acute ischemic stroke patients with severe neurological deficit (NIHSS ≥20) following a pre-specified analysis plan. Methods The pooled analysis of the IMS III and MR CLEAN trial included participants with an NIHSS ≥20 prior to intravenous (IV) t-PA treatment (IMS III) or randomization (MR CLEAN) who were treated with IV t-PA ≤ 3 hours of stroke onset. Our hypothesis was that participants with severe stroke randomized to endovascular therapy following IV t-PA would have improved 90-day outcome (distribution of modified Rankin scale [mRS] scores), as compared to those who received IV t-PA alone. Results Among 342 participants in the pooled analysis (194 from IMS III, 148 from MR CLEAN), an ordinal logistic regression model showed that the endovascular group had superior 90-day outcome compared to the IV t-PA group (adjusted odds ratio [aOR] 1.78; 95% confidence interval [CI] 1.20-2.66). In the logistic regression model of the dichotomous outcome (mRS 0-2, or ‘functional independence’), the endovascular group had superior outcomes (aOR 1.97; 95% CI 1.09-3.56). Functional independence (mRS ≤2) at 90 days was 25% in the endovascular group as compared to 14% in the IV t-PA group. Conclusions Endovascular therapy following IV t-PA within 3 hours of symptom onset improves functional outcome at 90 days after severe ischemic stroke. PMID:26486865

  11. Aneurysmal subarachnoid hemorrhage in patients under 35-years-old: a single-center experience.

    PubMed

    Chalouhi, Nohra; Teufack, Sonia; Chandela, Sid; Dalyai, Richard; Tjoumakaris, Stavropoula; Hasan, David M; Dumont, Aaron S; Gonzalez, L Fernando; Rosenwasser, Robert H; Jabbour, Pascal M

    2013-06-01

    Aneurysmal subarachnoid hemorrhage (SAH) is relatively uncommon in young adults. There is a paucity of data pertaining to the management of aneurysmal SAH in young patients, especially with endovascular therapy. We reviewed all SAH patients under the age of 35 years treated at Jefferson Hospital for Neuroscience, Philadelphia, USA, from 2004 to 2009. A total of 40 patients (15 males and 25 females) under the age of 35 were treated for aneurysmal SAH. The average patient age was 30 years (17-35 yo); 25 (62.5%) were smokers. Seventeen patients presented with a Hunt and Hess Grade I or II (42.5%), 20 with a Grade III (50%), and 3 with a Grade IV (7.5%). Thirty-two aneurysms (80%) were located in the anterior circulation and 8 (20%) in the posterior circulation. Thirty-five patients (87.5%) were treated with coil embolization versus 5 with craniotomy and clipping. The endovascular and microsurgical occlusion rates were 90.6% and 100%, respectively. There were no procedural complications with endovascular therapy. Of 35 patients undergoing endovascular treatment, 24 (68.6%) had excellent outcomes at time of discharge with a Glasgow outcome scale of 5. There were no deaths in the series. No patient experienced a rehemorrhage after endovascular treatment. Smoking, female sex, and anterior circulation aneurysms are highly prevalent in young adults with SAH. Endovascular treatment resulted in an overall favorable outcome with no rehemorrhages in patients under the age of 35 years. Our results suggest that endovascular therapy is a reasonable treatment for young patients with SAH. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. [Hybrid operating rooms: only for advanced endovascular procedures?].

    PubMed

    Verhoeven, E; Katsargyris, A; Töpel, I; Steinbauer, M

    2013-10-01

    The evolution of endovascular techniques has led to the concept of the "hybrid operating room" (hybrid OR). A hybrid OR combines the sterility of an OR in an operating theatre environment with a high-quality fixed imaging system. On the basis of these advantages it would be desirable that an angio-hybrid OR becomes a standard requirement for endovascular surgery. In Great Britain guidelines have already been published that require a hybrid OR even for normal endovascular management of the infrarenal aorta. However, in Germany there are no guidelines from professional societies or formal rules from the federal joint committee, thus in this article a classification of endovascular procedures according to their complexity and the necessary infrastructures are proposed in order to define particular procedures that should only be performed in an angio-hybrid OR. According to our experience, endovascular procedures can be classified into four categories based on their complexity and the requirements regarding fluoroscopy: level 1: standard EVAR, TEVAR, iliac and popliteal artery procedures; level 2: iliac branched (IBD) and standard (2 fenestrations for the renal arteries and a scallop for the superior mesenteric artery) fenestrated stent-grafting; level 3: more complex fenestrated procedures (three or four fenestrations); and level 4: branched stent-grafting for TAAA. At this moment it is still acceptable to perform level 1 and level 2 procedures outside of a hybrid OR. In our opinion, it is not recommended to perform level 3 and level 4 endovascular procedures without a hybrid OR. Georg Thieme Verlag KG Stuttgart · New York.

  13. Hybrid endovascular repair in aortic arch pathologies: a retrospective study.

    PubMed

    Ma, Xiaohui; Guo, Wei; Liu, Xiaoping; Yin, Tai; Jia, Xin; Xiong, Jiang; Zhang, Hongpeng; Wang, Lijun

    2010-11-18

    The aortic arch presents specific challenges to endovascular repair. Hybrid repair is increasingly evolving as an alternative option for selected patients, and promising initial results have been reported. The aim of this study was to introduce our experiences and evaluate mid-term results of supra aortic transpositions for extended endovascular repair of aortic arch pathologies. From December 2002 to January 2008, 25 patients with thoracic aortic aneurysms and dissections involving the aortic arch were treated with hybrid endovascular treatment in our center. Of the 25 cases, 14 were atherosclerotic thoracic aortic aneurysms and 11 were thoracic aortic dissection. The hybrid repair method included total-arch transpositions (15 cases) or hemi-arch transpositions (10 cases), and endovascular procedures. All hybrid endovascular procedures were completed successfully. Three early residual type-I endoleaks and one type-II endoleak were observed. Stroke occurred in three patients (8%) during the in-hospital stage. The perioperative mortality rate was 4%; one patients died post-operatively from catheter related complications. The average follow-up period was 15 ± 5.8 months (range, 1-41 months). The overall crude survival rate at 15 months was 92% (23/25). During follow-up, new late endoleaks and stent-raft related complications were not observed. One case (4%) developed a unilateral lower limb deficit at 17 days and was readmitted to hospital. In conclusion, the results are encouraging for endovascular aortic arch repair in combination with supra-aortic transposition in high risk cases. Aortic endografting offers good mid-term results. Mid-term results of the hybrid approach in elderly patients with aortic arch pathologies are satisfying.

  14. Endovascular reconstruction of popliteal and infrapopliteal arteries for limb salvage and wound healing in patients with critical limb ischemia – A retrospective analysis

    PubMed Central

    Khanolkar, Uday B.; Ephrem, Biju

    2016-01-01

    Background Advancement in endovascular techniques has led to rapid growth in endovascular revascularization, and it has emerged as a treatment for critical limb ischemia (CLI). Clinical effectiveness of revascularization has been frequently judged by vessel patency and limb salvage, but there is paucity of reports on outcomes of the wound. We present a retrospective analysis of immediate angiographic and 3-month clinical outcome of patients who underwent endovascular reconstruction of popliteal and infrapopliteal arteries for CLI. Methods All patients who underwent endovascular reconstruction of popliteal and/or infrapopliteal arteries for CLI and >70% stenosis on digital subtraction angiography between March 2010 and November 2014 and had a clinical follow-up of at least 3 months were selected for analysis. Results 34 patients underwent endovascular reconstruction. 9 patients (26%) underwent only POBA and remaining 25 (74%) underwent additional stenting. 13 patients (38%) had multiple segmental revascularization. 24 patients (71%) had successful vessel recanalization. Linear flow to foot in at least one artery could be achieved in 20 patients (59%) post revascularization. Successful wound healing occurred in 11 (35%) patients with an additional 7 (21%) patients showing clinical improvement in their wounds. Limb salvage was achieved in 33 patients (97%) at 3-month follow-up. Conclusion Endovascular revascularization of popliteal and infrapopliteal arteries is a feasible, safe, and effective procedure for the treatment of CLI. Normal inflow and outflow with at least one of the three infrapopliteal vessels being patent is essential for adequate healing of chronic ulcers and prevention of major amputation. PMID:26896272

  15. The model for Fundamentals of Endovascular Surgery (FEVS) successfully defines the competent endovascular surgeon.

    PubMed

    Duran, Cassidy; Estrada, Sean; O'Malley, Marcia; Sheahan, Malachi G; Shames, Murray L; Lee, Jason T; Bismuth, Jean

    2015-12-01

    Fundamental skills testing is now required for certification in general surgery. No model for assessing fundamental endovascular skills exists. Our objective was to develop a model that tests the fundamental endovascular skills and differentiates competent from noncompetent performance. The Fundamentals of Endovascular Surgery model was developed in silicon and virtual-reality versions. Twenty individuals (with a range of experience) performed four tasks on each model in three separate sessions. Tasks on the silicon model were performed under fluoroscopic guidance, and electromagnetic tracking captured motion metrics for catheter tip position. Image processing captured tool tip position and motion on the virtual model. Performance was evaluated using a global rating scale, blinded video assessment of error metrics, and catheter tip movement and position. Motion analysis was based on derivations of speed and position that define proficiency of movement (spectral arc length, duration of submovement, and number of submovements). Performance was significantly different between competent and noncompetent interventionalists for the three performance measures of motion metrics, error metrics, and global rating scale. The mean error metric score was 6.83 for noncompetent individuals and 2.51 for the competent group (P < .0001). Median global rating scores were 2.25 for the noncompetent group and 4.75 for the competent users (P < .0001). The Fundamentals of Endovascular Surgery model successfully differentiates competent and noncompetent performance of fundamental endovascular skills based on a series of objective performance measures. This model could serve as a platform for skills testing for all trainees. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  16. Content Validation and Evaluation of an Endovascular Teamwork Assessment Tool.

    PubMed

    Hull, L; Bicknell, C; Patel, K; Vyas, R; Van Herzeele, I; Sevdalis, N; Rudarakanchana, N

    2016-07-01

    To modify, content validate, and evaluate a teamwork assessment tool for use in endovascular surgery. A multistage, multimethod study was conducted. Stage 1 included expert review and modification of the existing Observational Teamwork Assessment for Surgery (OTAS) tool. Stage 2 included identification of additional exemplar behaviours contributing to effective teamwork and enhanced patient safety in endovascular surgery (using real-time observation, focus groups, and semistructured interviews of multidisciplinary teams). Stage 3 included content validation of exemplar behaviours using expert consensus according to established psychometric recommendations and evaluation of structure, content, feasibility, and usability of the Endovascular Observational Teamwork Assessment Tool (Endo-OTAS) by an expert multidisciplinary panel. Stage 4 included final team expert review of exemplars. OTAS core team behaviours were maintained (communication, coordination, cooperation, leadership team monitoring). Of the 114 OTAS behavioural exemplars, 19 were modified, four removed, and 39 additional endovascular-specific behaviours identified. Content validation of these 153 exemplar behaviours showed that 113/153 (73.9%) reached the predetermined Item-Content Validity Index rating for teamwork and/or patient safety. After expert team review, 140/153 (91.5%) exemplars were deemed to warrant inclusion in the tool. More than 90% of the expert panel agreed that Endo-OTAS is an appropriate teamwork assessment tool with observable behaviours. Some concerns were noted about the time required to conduct observations and provide performance feedback. Endo-OTAS is a novel teamwork assessment tool, with evidence for content validity and relevance to endovascular teams. Endo-OTAS enables systematic objective assessment of the quality of team performance during endovascular procedures. Copyright © 2016. Published by Elsevier Ltd.

  17. Length of carotid stenosis predicts peri-procedural stroke or death and restenosis in patients randomized to endovascular treatment or endarterectomy.

    PubMed

    Bonati, Leo H; Ederle, Jörg; Dobson, Joanna; Engelter, Stefan; Featherstone, Roland L; Gaines, Peter A; Beard, Jonathan D; Venables, Graham S; Markus, Hugh S; Clifton, Andrew; Sandercock, Peter; Brown, Martin M

    2014-04-01

    The anatomy of carotid stenosis may influence the outcome of endovascular treatment or carotid endarterectomy. Whether anatomy favors one treatment over the other in terms of safety or efficacy has not been investigated in randomized trials. In 414 patients with mostly symptomatic carotid stenosis randomized to endovascular treatment (angioplasty or stenting; n = 213) or carotid endarterectomy (n = 211) in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS), the degree and length of stenosis and plaque surface irregularity were assessed on baseline intraarterial angiography. Outcome measures were stroke or death occurring between randomization and 30 days after treatment, and ipsilateral stroke and restenosis ≥50% during follow-up. Carotid stenosis longer than 0.65 times the common carotid artery diameter was associated with increased risk of peri-procedural stroke or death after both endovascular treatment [odds ratio 2.79 (1.17-6.65), P = 0.02] and carotid endarterectomy [2.43 (1.03-5.73), P = 0.04], and with increased long-term risk of restenosis in endovascular treatment [hazard ratio 1.68 (1.12-2.53), P = 0.01]. The excess in restenosis after endovascular treatment compared with carotid endarterectomy was significantly greater in patients with long stenosis than with short stenosis at baseline (interaction P = 0.003). Results remained significant after multivariate adjustment. No associations were found for degree of stenosis and plaque surface. Increasing stenosis length is an independent risk factor for peri-procedural stroke or death in endovascular treatment and carotid endarterectomy, without favoring one treatment over the other. However, the excess restenosis rate after endovascular treatment compared with carotid endarterectomy increases with longer stenosis at baseline. Stenosis length merits further investigation in carotid revascularisation trials. © 2013 The Authors. International Journal of Stroke © 2013 World Stroke Organization.

  18. Outcomes of Infrainguinal Revascularizations with Endovascular First Strategy in Critical Limb Ischemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jens, Sjoerd, E-mail: s.jens@amc.uva.nl; Conijn, Anne P., E-mail: a.p.conijn@amc.uva.nl; Frans, Franceline A., E-mail: f.a.frans@amc.uva.nl

    PurposeThis study was designed to study the outcome of infrainguinal revascularization in patients with critical limb ischemia (CLI) in an institution with a preference towards endovascular intervention first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age.MethodsA prospective, observational cohort study was conducted between May 2007 and May 2010 in patients presenting with CLI. At baseline, the optimal treatment was selected, i.e., endovascular or surgical treatment. In case of uncertainty about the preferred treatment, a multidisciplinary team (MDT) was consulted. Primary endpoints were quality of life and functional status 6 and 12 monthsmore » after initial intervention, assessed by the VascuQol and AMC Linear Disability Score questionnaires, respectively.ResultsIn total, 113 patients were included; 86 had an endovascular intervention and 27 had surgery. During follow-up, 41 % underwent an additional ipsilateral revascularisation procedure. For the total population, and endovascular and surgery subgroups, the VascuQol sum scores improved after 6 and 12 months (p < 0.01 for all outcomes) compared with baseline. The functional status improved (p = 0.043) after 12 months compared with baseline for the total population. Functional status of the surgery subgroup improved significantly after 6 (p = 0.031) and 12 (p = 0.044) months, but not that of the endovascular subgroup.ConclusionsOverall, the strategy of performing endovascular treatment first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age has comparable or even slightly better results compared with the BASIL trial and other cohort studies. All vascular groups should discuss whether their treatment strategy should be directed at treating CLI patients preferably endovascular first and consider implementing an MDT to optimize patient outcomes.« less

  19. Endovascular strategy or open repair for ruptured abdominal aortic aneurysm: one-year outcomes from the IMPROVE randomized trial

    PubMed Central

    Braithwaite, Bruce; Cheshire, Nicholas J.; Greenhalgh, Roger M.; Grieve, Richard; Hassan, Tajek B.; Hinchliffe, Robert; Howell, Simon; Moore, Fionna; Nicholson, Anthony A.; Soong, Chee V.; Thompson, Matt M.; Thompson, Simon G.; Ulug, Pinar; Heatley, Francine; Anjum, Aisha; Kalinowska, Gosia; Sweeting, Michael J.; Thompson, Simon G.; Gomes, Manuel; Grieve, Richard; Powell, Janet T.; Ashleigh, Ray; Gomes, Manuel; Greenhalgh, Roger M.; Grieve, Richard; Hinchliffe, Robert; Sweeting, Michael; Thompson, Matt M.; Thompson, Simon G.; Ulug, Pinar; Roberts, Ian; Bell, Peter R. F.; Cheetham, Anne; Stephany, Jenny; Warlow, Charles; Lamont, Peter; Moss, Jonathan; Tijssen, Jan; Braithwaite, Bruce; Nicholson, Anthony A.; Thompson, Matthew; Ashleigh, Ray; Thompson, Luke; Cheshire, Nicholas J.; Boyle, Jonathan R.; Serracino-Inglott, Ferdinand; Thompson, Matt M.; Hinchliffe, Robert J.; Bell, Rachel; Wilson, Noel; Bown, Matt; Dennis, Martin; Davis, Meryl; Ashleigh, Ray; Howell, Simon; Wyatt, Michael G.; Valenti, Domenico; Bachoo, Paul; Walker, Paul; MacSweeney, Shane; Davies, Jonathan N.; Rittoo, Dynesh; Parvin, Simon D.; Yusuf, Waquar; Nice, Colin; Chetter, Ian; Howard, Adam; Chong, Patrick; Bhat, Raj; McLain, David; Gordon, Andrew; Lane, Ian; Hobbs, Simon; Pillay, Woolagasen; Rowlands, Timothy; El-Tahir, Amin; Asquith, John; Cavanagh, Steve; Dubois, Luc; Forbes, Thomas L.; Ashworth, Emily; Baker, Sara; Barakat, Hashem; Brady, Claire; Brown, Joanne; Bufton, Christine; Chance, Tina; Chrisopoulou, Angela; Cockell, Marie; Croucher, Andrea; Dabee, Leela; Dewhirst, Nikki; Evans, Jo; Gibson, Andy; Gorst, Siobhan; Gough, Moira; Graves, Lynne; Griffin, Michelle; Hatfield, Josie; Hogg, Florence; Howard, Susannah; Hughes, Cían; Metcalfe, David; Lapworth, Michelle; Massey, Ian; Novick, Teresa; Owen, Gareth; Parr, Noala; Pintar, David; Spencer, Sarah; Thomson, Claire; Thunder, Orla; Wallace, Tom; Ward, Sue; Wealleans, Vera; Wilson, Lesley; Woods, Janet; Zheng, Ting

    2015-01-01

    Aims To report the longer term outcomes following either a strategy of endovascular repair first or open repair of ruptured abdominal aortic aneurysm, which are necessary for both patient and clinical decision-making. Methods and results This pragmatic multicentre (29 UK and 1 Canada) trial randomized 613 patients with a clinical diagnosis of ruptured aneurysm; 316 to an endovascular first strategy (if aortic morphology is suitable, open repair if not) and 297 to open repair. The principal 1-year outcome was mortality; secondary outcomes were re-interventions, hospital discharge, health-related quality-of-life (QoL) (EQ-5D), costs, Quality-Adjusted-Life-Years (QALYs), and cost-effectiveness [incremental net benefit (INB)]. At 1 year, all-cause mortality was 41.1% for the endovascular strategy group and 45.1% for the open repair group, odds ratio 0.85 [95% confidence interval (CI) 0.62, 1.17], P = 0.325, with similar re-intervention rates in each group. The endovascular strategy group and open repair groups had average total hospital stays of 17 and 26 days, respectively, P < 0.001. Patients surviving rupture had higher average EQ-5D utility scores in the endovascular strategy vs. open repair groups, mean differences 0.087 (95% CI 0.017, 0.158), 0.068 (95% CI −0.004, 0.140) at 3 and 12 months, respectively. There were indications that QALYs were higher and costs lower for the endovascular first strategy, combining to give an INB of £3877 (95% CI £253, £7408) or €4356 (95% CI €284, €8323). Conclusion An endovascular first strategy for management of ruptured aneurysms does not offer a survival benefit over 1 year but offers patients faster discharge with better QoL and is cost-effective. Clinical trial registration ISRCTN 48334791. PMID:25855369

  20. Endovascular strategy or open repair for ruptured abdominal aortic aneurysm: one-year outcomes from the IMPROVE randomized trial.

    PubMed

    2015-08-14

    To report the longer term outcomes following either a strategy of endovascular repair first or open repair of ruptured abdominal aortic aneurysm, which are necessary for both patient and clinical decision-making. This pragmatic multicentre (29 UK and 1 Canada) trial randomized 613 patients with a clinical diagnosis of ruptured aneurysm; 316 to an endovascular first strategy (if aortic morphology is suitable, open repair if not) and 297 to open repair. The principal 1-year outcome was mortality; secondary outcomes were re-interventions, hospital discharge, health-related quality-of-life (QoL) (EQ-5D), costs, Quality-Adjusted-Life-Years (QALYs), and cost-effectiveness [incremental net benefit (INB)]. At 1 year, all-cause mortality was 41.1% for the endovascular strategy group and 45.1% for the open repair group, odds ratio 0.85 [95% confidence interval (CI) 0.62, 1.17], P = 0.325, with similar re-intervention rates in each group. The endovascular strategy group and open repair groups had average total hospital stays of 17 and 26 days, respectively, P < 0.001. Patients surviving rupture had higher average EQ-5D utility scores in the endovascular strategy vs. open repair groups, mean differences 0.087 (95% CI 0.017, 0.158), 0.068 (95% CI -0.004, 0.140) at 3 and 12 months, respectively. There were indications that QALYs were higher and costs lower for the endovascular first strategy, combining to give an INB of £3877 (95% CI £253, £7408) or €4356 (95% CI €284, €8323). An endovascular first strategy for management of ruptured aneurysms does not offer a survival benefit over 1 year but offers patients faster discharge with better QoL and is cost-effective. ISRCTN 48334791. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  1. Identifying patients with AAA with the highest risk following endovascular repair.

    PubMed

    Cadili, Ali; Turnbull, Robert; Hervas-Malo, Marilou; Ghosh, Sunita; Chyczij, Harold

    2012-08-01

    It has been demonstrated that endovascular repair of arterial disease results in reduced perioperative morbidity and mortality compared to open surgical repair. The rates of complications and need for reinterventions, however, have been found to be higher than that in open repair. The purpose of this study was to identify the predictors of endograft complications and mortality in patients undergoing endovascular abdominal aortic aneurysm (AAA) repair; specifically, our aim was to identify a subset of patients with AAA whose risk of periprocedure mortality was so high that they should not be offered endovascular repair. We undertook a prospective review of patients with AAA receiving endovascular therapy at a single institution. Collected variables included age, gender, date of procedure, indication for procedure, size of aneurysm (where applicable), type of endograft used, presence of rupture, American Society of Anesthesiologists (ASA) class, major medical comorbidities, type of anesthesia (general, epidural, or local), length of intensive care unit (ICU) stay, and length of hospital stay. These factors were correlated with the study outcomes (overall mortality, graft complications, morbidity, and reintervention) using univariate and multivariate logistic regression. A total of 199 patients underwent endovascular AAA repair during the study period. The ICU stay, again, was significantly correlated with the primary outcomes (death and graft complications). In addition, length of hospital stay greater than 3 days, also emerged as a statistically significant predictor of graft complications in this subgroup (P = .024). Survival analysis for patients with AAA revealed that age over 85 years and ICU stay were predictive of decreased survival. Statistical analysis for other subgroups of patients (inflammatory AAA or dissection) was not performed due to the small numbers in these subgroups. Patients with AAA greater than 85 years of age are at a greater risk of mortality following endovascular repair. In addition, patients who are expected to require postprocedure ICU admission are also at an increased risk of mortality following endovascular repair.

  2. Visuospatial and psychomotor aptitude predicts endovascular performance of inexperienced individuals on a virtual reality simulator.

    PubMed

    Van Herzeele, Isabelle; O'Donoghue, Kevin G L; Aggarwal, Rajesh; Vermassen, Frank; Darzi, Ara; Cheshire, Nicholas J W

    2010-04-01

    This study evaluated virtual reality (VR) simulation for endovascular training of medical students to determine whether innate perceptual, visuospatial, and psychomotor aptitude (VSA) can predict initial and plateau phase of technical endovascular skills acquisition. Twenty medical students received didactic and endovascular training on a commercially available VR simulator. Each student treated a series of 10 identical noncomplex renal artery stenoses endovascularly. The simulator recorded performance data instantly and objectively. An experienced interventionalist rated the performance at the initial and final sessions using generic (out of 40) and procedure-specific (out of 30) rating scales. VSA were tested with fine motor dexterity (FMD, Perdue Pegboard), psychomotor ability (minimally invasive virtual reality surgical trainer [MIST-VR]), image recall (Rey-Osterrieth), and organizational aptitude (map-planning). VSA performance scores were correlated with the assessment parameters of endovascular skills at commencement and completion of training. Medical students exhibited statistically significant learning curves from the initial to the plateau performance for contrast usage (medians, 28 vs 17 mL, P < .001), total procedure time (2120 vs 867 seconds, P < .001), and fluoroscopy time (993 vs. 507 seconds, P < .001). Scores on generic and procedure-specific rating scales improved significantly (10 vs 25, P < .001; 8 vs 17 P < .001). Significant correlations were noted for FMD with initial and plateau sessions for fluoroscopy time (r(s) = -0.564, P = .010; r(s) = -.449, P = .047). FMD correlated with procedure-specific scores at the initial session (r(s) = .607, P = .006). Image recall correlated with generic skills at the end of training (r(s) = .587, P = .006). Simulator-based training in endovascular skills improved performance in medical students. There were significant correlations between initial endovascular skill and fine motor dexterity as well as with image recall at end of the training period. In addition to current recruitment strategies, VSA may be a useful tool for predictive validity studies.

  3. Transatlantic Multispecialty Consensus on Fundamental Endovascular Skills: Results of a Delphi Consensus Study.

    PubMed

    Maertens, H; Aggarwal, R; Macdonald, S; Vermassen, F; Van Herzeele, I

    2016-01-01

    The aim of this study was to establish a consensus on Fundamental Endovascular Skills (FES) for educational purposes and development of training curricula for endovascular procedures. The term "Fundamental Endovascular Skills" is widely used; however, the current literature does not explicitly describe what skills are included in this concept. Endovascular interventions are performed by several specialties that may have opposing perspectives on these skills. A two round Delphi questionnaire approach was used. Experts from interventional cardiology, interventional radiology, and vascular surgery from the United States and Europe were invited to participate. An electronic questionnaire was generated by endovascular therapists with an appropriate educational background but who would not participate in subsequent rounds. The questionnaire consisted of 50 statements describing knowledge, technical, and behavioral skills during endovascular procedures. Experts received the questionnaires by email. They were asked to rate the importance of each skill on a Likert scale from 1 to 5. A statement was considered fundamental when more than 90% of the experts rated it 4 or 5 out of 5. Twenty-three of 53 experts invited agreed to participate: six interventional radiologists (2 USA, 4 Europe), 10 vascular surgeons (4 USA, 6 Europe), and seven interventional cardiologists (4 USA, 3 Europe). There was a 100% response rate in the first round and 87% in the second round. Results showed excellent consensus among responders (Cronbach's alpha = .95 first round; .93 second round). Ninety percent of all proposed skills were considered fundamental. The most critical skills were determined. A transatlantic multispecialty consensus was achieved about the content of "FES" among interventional radiologists, interventional cardiologists, and vascular surgeons from Europe and the United States. These results can serve as directive principles for developing endovascular training curricula. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Making sense of endovascular therapies for femoropopliteal disease.

    PubMed

    Altin, S Elissa; Abbott, J Dawn

    2018-06-01

    The femoropoliteal segment is a common target for endovascular intervention and the unique biomechanical forces on the arteries increase the risk of restenosis This large meta-analysis supports drug coated balloons as the initial endovascular strategy due to lower risk of target lesion revascularization compared to other modalities Whether there are subgroups of patients or lesion types that benefit from an alternative revascularization approach is unclear and warrants investigation. © 2018 Wiley Periodicals, Inc.

  5. Epithelioid Angiosarcoma With Metastatic Disease After Endovascular Therapy of Abdominal Aortic Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmehl, Joerg, E-mail: joerg.schmehl@med.uni-tuebingen.de; Scharpf, Marcus; Brechtel, Klaus

    2012-02-15

    Malignancies of the aortic wall represent a rare condition, and only a few reports have covered cases of sarcomas arising at the site of a prosthesis made of Dacron. A coincidence with endovascular repair has only been reported in one case to date. We report a patient with epithelioid angiosarcoma and metastatic disease, which was found in an aneurysmal sac after endovascular aortic repair for abdominal aortic aneurysm.

  6. Ruptured abdominal aortic aneurysm: Is endovascular aneurysm repair the answer for everybody?

    PubMed

    Aziz, Faisal

    2016-03-01

    Treatment paradigms for elective repair of asymptomatic abdominal aortic aneurysms (AAA) have evolved during the past 2 decades, with endovascular aneurysm repair as the preferred treatment modality. The patient care strategy for emergent treatment for ruptured AAA is not as straightforward, due in part to surgeon expertise and stent-graft availability at the institution. Although most reports have extrapolated elective endovascular aneurysm repair feasibility data to the ruptured AAA patient and the aneurysm anatomy, these expectations should be interpreted with caution. In the absence of level I evidence, and lack of adequate local hospital resources, endovascular aneurysm repair-first policy might not be feasible for all the patients who present with ruptured AAA. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Endovascular Thrombectomy for Acute Ischemic Stroke: A Meta-analysis.

    PubMed

    Badhiwala, Jetan H; Nassiri, Farshad; Alhazzani, Waleed; Selim, Magdy H; Farrokhyar, Forough; Spears, Julian; Kulkarni, Abhaya V; Singh, Sheila; Alqahtani, Abdulrahman; Rochwerg, Bram; Alshahrani, Mohammad; Murty, Naresh K; Alhazzani, Adel; Yarascavitch, Blake; Reddy, Kesava; Zaidat, Osama O; Almenawer, Saleh A

    2015-11-03

    Endovascular intervention for acute ischemic stroke improves revascularization. But trials examining endovascular therapy yielded variable functional outcomes, and the effect of endovascular intervention among subgroups needs better definition. To examine the association between endovascular mechanical thrombectomy and clinical outcomes among patients with acute ischemic stroke. We systematically searched MEDLINE, EMBASE, CINAHL, Google Scholar, and the Cochrane Library without language restriction through August 2015. Eligible studies were randomized clinical trials of endovascular therapy with mechanical thrombectomy vs standard medical care, which includes the use of intravenous tissue plasminogen activator (tPA). Independent reviewers evaluated the quality of studies and abstracted the data. We calculated odds ratios (ORs) and 95% CIs for all outcomes using random-effects meta-analyses and performed subgroup and sensitivity analyses to examine whether certain imaging, patient, treatment, or study characteristics were associated with improved functional outcome. The strength of the evidence was examined for all outcomes using the GRADE method. Ordinal improvement across modified Rankin scale (mRS) scores at 90 days, functional independence (mRS score, 0-2), angiographic revascularization at 24 hours, symptomatic intracranial hemorrhage within 90 days, and all-cause mortality at 90 days. Data were included from 8 trials involving 2423 patients (mean [SD] age, 67.4 [14.4] years; 1131 [46.7%] women), including 1313 who underwent endovascular thrombectomy and 1110 who received standard medical care with tPA. In a meta-analysis of these trials, endovascular therapy was associated with a significant proportional treatment benefit across mRS scores (OR, 1.56; 95% CI, 1.14-2.13; P = .005). Functional independence at 90 days (mRS score, 0-2) occurred among 557 of 1293 patients (44.6%; 95% CI, 36.6%-52.8%) in the endovascular therapy group vs 351 of 1094 patients (31.8%; 95% CI, 24.6%-40.0%) in the standard medical care group (risk difference, 12%; 95% CI, 3.8%-20.3%; OR, 1.71; 95% CI, 1.18-2.49; P = .005). Compared with standard medical care, endovascular thrombectomy was associated with significantly higher rates of angiographic revascularization at 24 hours (75.8% vs 34.1%; OR, 6.49; 95% CI, 4.79-8.79; P < .001) but no significant difference in rates of symptomatic intracranial hemorrhage within 90 days (70 events [5.7%] vs 53 events [5.1%]; OR, 1.12; 95% CI, 0.77-1.63; P = .56) or all-cause mortality at 90 days (218 deaths [15.8%] vs 201 deaths [17.8%]; OR, 0.87; 95% CI, 0.68-1.12; P = .27). Among patients with acute ischemic stroke, endovascular therapy with mechanical thrombectomy vs standard medical care with tPA was associated with improved functional outcomes and higher rates of angiographic revascularization, but no significant difference in symptomatic intracranial hemorrhage or all-cause mortality at 90 days.

  8. Cost-Effectiveness Analysis of Initial Treatment Strategies for Nonembolic Acute Limb Ischemia Using Real-Word Data.

    PubMed

    Vaidya, Varun; Gangan, Nilesh; Comerota, Anthony; Lurie, Fedor

    2017-02-01

    Nonembolic acute limb ischemia (ALI) is a condition characterized by a sudden decrease in limb perfusion and requires immediate interventions. There are multiple treatment options available including surgery, catheter-directed thrombolysis (CDT), endovascular procedures, and hybrid treatment (a combination of open and endovascular techniques). Randomized trials provide information only on clinical efficacy, but not on economic outcomes. The objective of the study was to perform the cost-effective analysis comparing different treatment alternatives of ALI. The data were collected from 4r ProMedica community hospitals in the Northwest Ohio from January 2009 to December 2012. Patients were included if they were treated within 14 days of onset of symptoms for nonembolic ALI and were divided into groups of receiving CDT, surgery, endovascular, or hybrid treatments. Demographics, comorbidities, medications taken before admission, and smoking status were collected at baseline for all patients and were compared among the treatment groups. A cost-effectiveness decision tree was developed to calculate expected costs and life years gained associated with available treatment options. A probabilistic sensitivity analysis was also performed to check the robustness of the model. A population of 205 patients with the diagnosis of ALI was included and divided into different treatment groups. There was no major significant difference in baseline characteristics among the studied groups (P > 0.05). The total costs were $17,163.47 for surgery, $20,620.39 for endovascular, $21,277.61 for hybrid, and $30,675.42 for CDT. The life years gained were 17.25 for surgery, 18 for endovascular, 18 for hybrid, and 17 for CDT. CDT was dominated because of the high cost and the low effectiveness, while hybrid treatment was dominated when compared with endovascular treatment because these 2 treatments have similar outcomes. The incremental cost-effectiveness ratio of the endovascular group over the surgery group was found to be $4,609.23 per life year gained. The sensitivity analysis showed that the endovascular treatment was found to be cost-effective under willingness to pay $50,000. This study provides economic evaluation of ALI treatments for a defined clinical population in the real-world setting. Compared with other available alternatives, the endovascular treatment showed to be a cost-effective use of healthcare resources. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Cost Analysis of Initial Treatment With Endovascular Revascularization, Open Surgery, or Primary Major Amputation in Patients With Peripheral Artery Disease.

    PubMed

    Tang, Linda; Paravastu, Sharath C V; Thomas, Shannon D; Tan, Elaine; Farmer, Eric; Varcoe, Ramon L

    2018-05-01

    To compare the total initial treatment costs for open surgery, endovascular revascularization, and primary major amputation within a single-payer healthcare system. A multicenter, retrospective analysis was undertaken to evaluate 1138 patients with symptomatic peripheral artery disease (PAD) who underwent 1017 endovascular procedures, 86 open surgeries, and 35 major amputations between 2013 and 2016. A cost-mix analysis was performed on individual patient data generated for selected diagnosis-related groups. Mean costs are presented with the 95% confidence interval (CI). There was no intergroup difference in demographics or private health insurance status. However, the amputation group had a higher proportion of emergency procedures (68.6% vs 13.3% vs 27.9%, p<0.001) and critical limb ischemia (88.6% vs 35.9% vs 37.2%, p<0.001) compared with the endovascular therapy and open surgery groups, respectively. The endovascular revascularization group spent less time in hospital and used fewer intensive care unit (ICU) resources compared with the open surgery and major amputation groups (hospital length of stay: 3.4 vs 10.0 vs 20.2 days, p<0.01; ICU: 2.4 vs 22.6 vs 54.6 hours, p<0.01), respectively. While mean prosthetic and device costs were higher in the endovascular group [AUD$2770 vs AUD$1658 (open) and AUD$1219 (amputation), p<0.01], substantial disparities were observed in costs associated with longer operating theater times, length of stay, and ICU utilization, which resulted in significantly higher costs in the open and amputation groups. After adjusting for confounders, the AUD$18 396 (95% CI AUD$16 436 to AUD$20 356) mean cost per admission for the endovascular revascularization group was significantly less (p<0.001) than the open surgery (AUD$31 908, 95% CI AUD$28 285 to AUD$35 530) and major amputation groups (AUD$43 033, 95% CI AUD$37 706 to AUD$48 361). Endovascular revascularization procedures for PAD cost the health payer less compared with open surgery and primary amputation. While devices used to deliver contemporary endovascular therapy are more expensive, the reduction in bed days, ICU utilization, and related hospital resources results in a significantly lower mean total cost per admission for the initial treatment.

  10. The 100 most cited articles in the endovascular management of intracranial aneurysms.

    PubMed

    Maingard, Julian; Phan, Kevin; Ren, Yifan; Kok, Hong Kuan; Thijs, Vincent; Hirsch, Joshua A; Lee, Michael J; Chandra, Ronil V; Brooks, Duncan Mark; Asadi, Hamed

    2018-01-19

    Endovascular interventions for intracranial aneurysms have evolved substantially over the past several decades. A citation rank list is used to measure the scientific and/or clinical impact of an article. Our objective was to identify and analyze the characteristics of the 100 most cited articles in the field of endovascular therapy for intracranial aneurysms. We performed a retrospective bibliometric analysis between July and August 2017. Articles were searched on the Science Citation Index Expanded database using Web of Science in order to identify the most cited articles in the endovascular therapy of intracranial aneurysms since 1945. Using selected key terms ('intracranial aneurysm', 'aneurysm', 'aneurysmal subarachnoid', 'endovascular', 'coiling', 'stent-assisted', 'balloon-assisted', 'flow-diversion') yielded a total of 16 314 articles. The top 100 articles were identified and analyzed to extract relevant information, including citation count, authorship, article type, subject matter, institution, country of origin, and year of publication. Citations for the top 100 articles ranged from 133 to 1832. All articles were cited an average of 27 times per year. There were 45 prospective studies, including 7 level-II randomized controlled trials. Most articles were published in the 2000s (n=53), and the majority constituted level III or level IV evidence. Half of the top 100 articles arose from the USA. This study provides a comprehensive overview of the most cited articles in the endovascular management of intracranial aneurysms. It recognizes the contributions made by key authors and institutions, providing an important framework to an enhanced understanding of the evidence behind the endovascular treatment of aneurysms. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Endovascular Therapy Demonstrates Benefit over Intravenous Recombinant Tissue Plasminogen Activator Based on Repeatedly Measured National Institutes of Health Stroke Scale.

    PubMed

    Fan, Liqiong; Yeatts, Sharon D; Foster, Lydia D; Khatri, Pooja; Tomsick, Thomas; Broderick, Joseph P; Palesch, Yuko Y

    2017-03-01

    The Interventional Management of Stroke (IMS) III trial was a randomized controlled trial designed to compare the effect of endovascular therapy after intravenous recombinant tissue plasminogen activator (i.v. rt-PA) as compared to i.v. rt-PA alone. The primary outcome was modified Rankin Scale at 90 days. Secondary outcomes included National Institutes of Health Stroke Scale (NIHSS), which was assessed repeatedly through 90 days. The objective of this analysis is to evaluate the treatment effect of endovascular therapy over time on NIHSS. 656 subjects were enrolled in the IMS III trial, including 434 subjects randomized to endovascular therapy and 222 to i.v. rt-PA only. NIHSS scores evaluated at 40 min, 24 h, Day 5, and Day 90 were included in the analysis. A covariance structure model was used to investigate the treatment effect on NIHSS over time, adjusting for relevant covariates including baseline stroke severity. Model assumptions were valid. Based on the covariance structure model, after adjusting for relevant baseline covariates, a significant time-by-treatment interaction effect ( p = 0.0137) was observed. Only NIHSS at Day 90 showed a significant treatment effect ( p = 0.0473), with subjects in the endovascular arm having a lower NIHSS (less neurologic deficit) compared to the i.v. rt-PA arm. The IMS III trial demonstrated an endovascular treatment effect based on the secondary outcome of NIHSS. However, the magnitude of this treatment effect varied by the time of assessment. It was only at Day 90 that the endovascular arm had a significantly lower NIHSS compared to that in the i.v. rt-PA arm.

  12. 2015 American Heart Association/American Stroke Association Focused Update of the 2013 Guidelines for the Early Management of Patients With Acute Ischemic Stroke Regarding Endovascular Treatment: A Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association.

    PubMed

    Powers, William J; Derdeyn, Colin P; Biller, José; Coffey, Christopher S; Hoh, Brian L; Jauch, Edward C; Johnston, Karen C; Johnston, S Claiborne; Khalessi, Alexander A; Kidwell, Chelsea S; Meschia, James F; Ovbiagele, Bruce; Yavagal, Dileep R

    2015-10-01

    The aim of this guideline is to provide a focused update of the current recommendations for the endovascular treatment of acute ischemic stroke. When there is overlap, the recommendations made here supersede those of previous guidelines. This focused update analyzes results from 8 randomized, clinical trials of endovascular treatment and other relevant data published since 2013. It is not intended to be a complete literature review from the date of the previous guideline publication but rather to include pivotal new evidence that justifies changes in current recommendations. Members of the writing committee were appointed by the American Heart Association/American Stroke Association Stroke Council's Scientific Statement Oversight Committee and the American Heart Association/American Stroke Association Manuscript Oversight Committee. Strict adherence to the American Heart Association conflict of interest policy was maintained throughout the consensus process. Recommendations follow the American Heart Association/American Stroke Association methods of classifying the level of certainty of the treatment effect and the class of evidence. Prerelease review of the draft guideline was performed by 6 expert peer reviewers and by the members of the Stroke Council Scientific Statement Oversight Committee and Stroke Council Leadership Committee. Evidence-based guidelines are presented for the selection of patients with acute ischemic stroke for endovascular treatment, for the endovascular procedure, and for systems of care to facilitate endovascular treatment. Certain endovascular procedures have been demonstrated to provide clinical benefit in selected patients with acute ischemic stroke. Systems of care should be organized to facilitate the delivery of this care. © 2015 American Heart Association, Inc.

  13. A review of the surgical management of right-sided aortic arch aneurysms

    PubMed Central

    Barr, James G.; Sepehripour, Amir H.; Jarral, Omar A.; Tsipas, Pantelis; Kokotsakis, John; Kourliouros, Antonios; Athanasiou, Thanos

    2016-01-01

    Aneurysms and dissections of the right-sided aortic arch are rare and published data are limited to a few case reports and small series. The optimal treatment strategy of this entity and the challenges associated with their management are not yet fully investigated and conclusive. We performed a systematic review of the literature to identify all patients who underwent surgical or endovascular intervention for right aortic arch aneurysms or dissections. The search was limited to the articles published only in English. We focused on presentation and critically assessed different management strategies and outcomes. We identified 74 studies that reported 99 patients undergoing surgical or endovascular intervention for a right aortic arch aneurysm or dissection. The median age was 61 years. The commonest presenting symptoms were chest or back pain and dysphagia. Eighty-eight patients had an aberrant left subclavian artery with only 11 patients having the mirror image variant of a right aortic arch. The commonest pathology was aneurysm arising from a Kommerell's diverticulum occurring in over 50% of the patients. Twenty-eight patients had dissections, 19 of these were Type B and 9 were Type A. Eighty-one patients had elective operations while 18 had emergency procedures. Sixty-seven patients underwent surgical treatment, 20 patients had hybrid surgical and endovascular procedures and 12 had totally endovascular procedure. There were 5 deaths, 4 of which were in patients undergoing emergency surgery and none in the endovascular repair group. Aneurysms and dissections of a right-sided aortic arch are rare. Advances in endovascular treatment and hybrid surgical and endovascular management are making this rare pathology amenable to these approaches and may confer improved outcomes compared with conventional extensive repair techniques. PMID:27001673

  14. Long-term outcome of endovascular treatment versus medical care for carotid artery stenosis in patients not suitable for surgery and randomised in the Carotid and Vertebral Artery Transluminal Angioplasty study (CAVATAS).

    PubMed

    Ederle, Jörg; Featherstone, Roland L; Brown, Martin M

    2009-01-01

    Optimal treatment of carotid stenosis in patients not suitable for surgery is unclear. The Carotid and Vertebral Artery Transluminal Angioplasty study contained a trial comparing medical and endovascular treatment in patients not suitable for surgery. Forty patients were randomised to medical or endovascular treatment in equal numbers, and patients were followed up for up to 10 years. The primary outcome measure was defined as stroke or death during follow-up, analysed by intention-to-treat. Secondary analyses included disabling stroke, death, any stroke, any stroke or transient ischemic attack (TIA), all during follow-up. Baseline characteristics were similar. The risk of stroke, retinal infarction or death within 30 days of endovascular treatment was 5% (95% CI: 0.1-24.9%). By the study end, >50% of patients had suffered a recurrent TIA, stroke or died. One third of events were non-stroke deaths. Overall, there was no significant difference between medical and endovascular treatment in the primary outcome rate of stroke or death after randomisation (hazard ratio: 0.98, 95% CI: 0.39-2.48) or the rate of any stroke or TIA (hazard ratio: 1.43, 95% CI: 0.54-3.75). We failed to show superiority of endovascular treatment above medical care alone for carotid stenosis in a very small group of patients not suitable for surgical treatment. However, the trial randomised only 40 patients, and was therefore severely underpowered to detect clinically relevant treatment differences. Ongoing trials of carotid stenting will need to demonstrate improved safety and efficacy before endovascular treatment should enter routine practice. (c) 2009 S. Karger AG, Basel.

  15. A study of surgeons' postural muscle activity during open, laparoscopic, and endovascular surgery.

    PubMed

    Szeto, G P Y; Ho, P; Ting, A C W; Poon, J T C; Tsang, R C C; Cheng, S W K

    2010-07-01

    Different surgical procedures impose different physical demands on surgeons and high prevalence rates of neck and shoulder pain have been reported among general surgeons. Past research has examined electromyography in surgeons mainly during simulated conditions of laparoscopic and open surgery but not during real-time operations and not for long durations. The present study compares the neck-shoulder muscle activities in three types of surgery and between different surgeons. The relationships of postural muscle activities to musculoskeletal symptoms and personal factors also are examined. Twenty-five surgeons participated in the study (23 men). Surface electromyography (EMG) was recorded in the bilateral cervical erector spinae, upper trapezius, and anterior deltoid muscles during three types of surgical procedures: open, laparoscopic, and endovascular. In each procedure, EMG data were captured for 30 min to more than 1 h. The surgeons were asked to rate any musculoskeletal symptoms before and after surgery. The present study showed significantly higher muscle activities in the cervical erector spinae and upper trapezius muscles in open surgery compared with endovascular and laparoscopic procedures. Muscle activities were fairly similar between endovascular and laparoscopic surgery. The upper trapezius usually has an important role in stabilizing both the neck and upper limb posture, and this muscle also recorded higher activities in open compared with laparoscopic and endovascular surgeries. Surgeons reported similar degrees of musculoskeletal symptoms in open and laparoscopic surgeries, which were higher than endovascular surgery. The present study showed that open surgery imposed significantly greater physical demands on the neck muscles compared with endovascular and laparoscopic surgeries. This may be due to the lighter manual task demands of these minimally invasive surgeries compared with open procedures, which generally required more dynamic movements and more forceful exertions.

  16. Time to angiographic reperfusion in acute ischemic stroke: decision analysis.

    PubMed

    Vagal, Achala S; Khatri, Pooja; Broderick, Joseph P; Tomsick, Thomas A; Yeatts, Sharon D; Eckman, Mark H

    2014-12-01

    Our objective was to use decision analytic modeling to compare 2 treatment strategies of intravenous recombinant tissue-type plasminogen activator (r-tPA) alone versus combined intravenous r-tPA/endovascular therapy in a subgroup of patients with large vessel (internal carotid artery terminus, M1, and M2) occlusion based on varying times to angiographic reperfusion and varying rates of reperfusion. We developed a decision model using Interventional Management of Stroke (IMS) III trial data and comprehensive literature review. We performed 1-way sensitivity analyses for time to reperfusion and 2-way sensitivity for time to reperfusion and rate of reperfusion success. We also performed probabilistic sensitivity analyses to address uncertainty in total time to reperfusion for the endovascular approach. In the base case, endovascular approach yielded a higher expected utility (6.38 quality-adjusted life years) than the intravenous-only arm (5.42 quality-adjusted life years). One-way sensitivity analyses demonstrated superiority of endovascular treatment to intravenous-only arm unless time to reperfusion exceeded 347 minutes. Two-way sensitivity analysis demonstrated that endovascular treatment was preferred when probability of reperfusion is high and time to reperfusion is small. Probabilistic sensitivity results demonstrated an average gain for endovascular therapy of 0.76 quality-adjusted life years (SD 0.82) compared with the intravenous-only approach. In our post hoc model with its underlying limitations, endovascular therapy after intravenous r-tPA is the preferred treatment as compared with intravenous r-tPA alone. However, if time to reperfusion exceeds 347 minutes, intravenous r-tPA alone is the recommended strategy. This warrants validation in a randomized, prospective trial among patients with large vessel occlusions. © 2014 American Heart Association, Inc.

  17. Combination of endovascular graft exclusion and drug therapy in AAA with hypertension or hyperglycemia.

    PubMed

    Wang, Dile; Qu, Bihui; He, Tao

    2017-08-01

    The objective of the present study was to evaluate the efficacy of combination of endovascular graft exclusion and drugs for hypertension/hyperglycemia for the treatment of abdominal aortic aneurysm (AAA). We analyzed 156 patients with AAA. Eighty-four patients were hypertensive and 72 were hyperglycemic. After endovascular graft exclusion, hypertensive patients were divided into four groups and treated with cyclopenthiazide, reserpine, propranolol, and placebo respectively. Hyperglycemic patients were divided into three groups and treated with metformin, insulin, and placebo respectively. Body temperature and peripheral blood leukocytes were measured at day 1, 2, 7, and 14 after endovascular graft exclusion. Size of AAAs, blood pressure, and blood sugar were measured again after 1 year. In hypertensive patients, the size of AAAs reduced after endovascular graft exclusion, while the combined treatments with cyclopenthiazide, reserpine, or propranolol helped to reduce blood pressure (blood pressure decrease <10 mmHg (18/21), <10 mmHg (12/21), <10 mmHg (8/21), and <10 mmHg (10/21) in the control group, cyclopenthiazide group, reserpine group, and propranolol group, respectively. AAA size decreased in the control group (P<0.001) and in the other three groups (P<0.0001). Similar results were obtained in hyperglycemic patients. The size of AAAs reduced after endovascular graft exclusion. Combined treatment with Metformin and Insulin reduced blood sugar (control, blood sugar >7.8 mmol/L (22/24), AAA size (P<0.001); metformin, blood sugar >7.8 mmol/L (14/24), AAA size (P<0.0001); insulin, blood sugar >7.8 mmol/L (11/24), AAA size (P<0.0001). Combination of endovascular graft exclusion with medicine is more effective than the former treatment alone for AAA therapy.

  18. Implications of renal artery anatomy for endovascular repair using fenestrated, branched, or parallel stent graft techniques.

    PubMed

    Mendes, Bernardo C; Oderich, Gustavo S; Reis de Souza, Leonardo; Banga, Peter; Macedo, Thanila A; DeMartino, Randall R; Misra, Sanjay; Gloviczki, Peter

    2016-05-01

    This study evaluated renal artery (RA) and accessory renal artery (ARA) anatomy and implications for endovascular repair using fenestrated, branched, or parallel (chimney, snorkel, and periscope) stent graft techniques. We analyzed the digital computed tomography angiograms of 520 consecutive patients treated by open or fenestrated endovascular repair for complex abdominal aortic aneurysms (2000-2012). RA/ARA anatomy was assessed using diameter, length, angles, and kidney perfusion based on analysis of estimated volumetric kidney parenchyma. Endovascular suitability was determined by RA diameter ≥4 mm, length to RA bifurcation ≥13 mm, and preservation of >75% of a single kidney or >60% of two kidneys by volumetric kidney parenchyma analysis. There were 222 juxtarenal (43%), 241 suprarenal (46%), and 57 type IV thoracoabdominal aortic aneurysms (11%), Analysis of 1009 RAs and 177 ARAs showed endovascular incorporation was possible in 884 RAs (88%) and 30 ARAs (17%) using the proposed criteria. One or more factors rendered RA incorporation unsuitable in 97 patients (19%), including early bifurcation in 45 (9%), small diameter in 28 (5%), or inability to preserve kidney parenchyma in 28 (5%). Other anatomic issues were present in 170 patients (33%) that would increase technical difficulty to RA incorporation using transfemoral access, including excessive downward angulation in 125 (24%), high-grade stenosis in 51 (10%), or prior renal stents in 11 (2%). Independent of the endovascular technique that is selected to treat a complex abdominal aortic aneurysm, one of five patients has anatomic limitations to endovascular incorporation. In these patients, open repair may provide the best alterative to maximize RA patency and preserve renal function. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  19. Antithrombotic Strategies in Endovascular Interventions: Current Status and Future Directions.

    PubMed

    Shishehbor, Mehdi H; Katzen, Barry T

    2013-10-01

    Despite increasing numbers of endovascular interventions to treat arterial and venous disease, scant level 1 evidence is available regarding the role of antithrombotic and antiplatelet therapy in patients undergoing these procedures. The current practice in this regard is heterogeneous and has mainly been driven by data from coronary artery disease and percutaneous coronary intervention. This article discusses the role of antithrombotic and antiplatelet agents for endovascular intervention. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Redo thoracic endovascular aortic repair due to endoleak with celiac artery snorkeling.

    PubMed

    Planer, David; Bliagos, Dimitrios; Gray, William A

    2011-10-01

    Reintervention due to endoleak of aortic endograft repair is often challenging. Herein, we report endovascular endoleak repair in a patient with previous thoracic and abdominal endovascular grafts with extensive coverage of the aorta. The present technique included snorkeling of the celiac trunk to preserve antegrade flow in the celiac artery and to maintain future options for reintervention. Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  1. Total Endovascular Aortic Repair in a Patient with Marfan Syndrome.

    PubMed

    Amako, Mau; Spear, Rafaëlle; Clough, Rachel E; Hertault, Adrien; Azzaoui, Richard; Martin-Gonzalez, Teresa; Sobocinski, Jonathan; Haulon, Stéphan

    2017-02-01

    The aim of this study is to describe a total endovascular aortic repair with branched and fenestrated endografts in a young patient with Marfan syndrome and a chronic aortic dissection. Open surgery is the gold standard to treat aortic dissections in patients with aortic disease and Marfan syndrome. In 2000, a 38-year-old man with Marfan syndrome underwent open ascending aorta repair for an acute type A aortic dissection. One year later, a redo sternotomy was performed for aortic valve replacement. In 2013, the patient presented with endocarditis and pulmonary infection, which necessitated tracheostomy and temporary dialysis. In 2014, the first stage of the endovascular repair was performed using an inner branched endograft to exclude a 77-mm distal arch and descending thoracic aortic aneurysm. In 2015, a 63-mm thoracoabdominal aortic aneurysm was excluded by implantation of a 4-fenestrated endograft. Follow-up after both endovascular repairs was uneventful. Total aortic endovascular repair was successfully performed to treat a patient with arch and thoraco-abdominal aortic aneurysm associated with chronic aortic dissection and Marfan syndrome. The postoperative images confirmed patency of the endograft and its branches, and complete exclusion of the aortic false lumen. Endovascular repair is a treatment option in patients with connective tissue disease who are not candidates for open surgery. Long-term follow-up is required to confirm these favorable early outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Decision-Making in Critical Limb Ischemia: A Markov Simulation.

    PubMed

    Deutsch, Aaron J; Jain, C Charles; Blumenthal, Kimberly G; Dickinson, Mark W; Neilan, Anne M

    2017-11-01

    Critical limb ischemia (CLI) is a feared complication of peripheral vascular disease that often requires surgical management and may require amputation of the affected limb. We developed a decision model to inform clinical management for a 63-year-old woman with CLI and multiple medical comorbidities, including advanced heart failure and diabetes. We developed a Markov decision model to evaluate 4 strategies: amputation, surgical bypass, endovascular therapy (e.g. stent or revascularization), and medical management. We measured the impact of parameter uncertainty using 1-way, 2-way, and multiway sensitivity analyses. In the base case, endovascular therapy yielded similar discounted quality-adjusted life months (26.50 QALMs) compared with surgical bypass (26.34 QALMs). Both endovascular and surgical therapies were superior to amputation (18.83 QALMs) and medical management (11.08 QALMs). This finding was robust to a wide range of periprocedural mortality weights and was most sensitive to long-term mortality associated with endovascular and surgical therapies. Utility weights were not stratified by patient comorbidities; nonetheless, our conclusion was robust to a range of utility weight values. For a patient with CLI, endovascular therapy and surgical bypass provided comparable clinical outcomes. However, this finding was sensitive to long-term mortality rates associated with each procedure. Both endovascular and surgical therapies were superior to amputation or medical management in a range of scenarios. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience.

    PubMed

    Marjanović, Ivan; Tomić, Aleksandar; Marić, Nebojša; Pecarski, Danijela; Šarac, Momir; Paunović, Dragana; Rusović, Siniša

    2016-10-01

    We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA) occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  4. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries usingmore » the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.« less

  5. Endovascular embolization of varicoceles using n-butyl cyanoacrylate (NBCA) glue

    PubMed Central

    Pietura, Radosław; Toborek, Michał; Dudek, Aneta; Boćkowska, Agata; Janicka, Joanna; Piekarski, Paweł

    2013-01-01

    Summary Background: Varicoceles are abnormally dilated veins within the pampiniform plexus. They are caused by reflux of blood in the internal spermatic vein. The incidence of varicoceles is approximately 10–15% of the adolescent male population. The etiology of varicoceles is probably multifactorial. The diagnosis is based on Doppler US. Treatment could be endovascular or surgical. The aim of the study was to describe and evaluate a novel method of endovascular embolization of varicoceles using n-butyl cyanoacrylate (NBCA) glue. Material/Methods: 17 patients were subjected to endovascular treatment of varicoceles using NBCA. A 2.8 Fr microcatheter and a 1:1 mixture of NBCA and lipiodol were used for embolization of the spermatic vein. Results: All 17 procedures were successful. There were no complications. Discussion: Embolization of varicoceles using NBCA glue is efficient and safe for all patients. The method should be considered as a method of choice in all patients. Phlebography and Valsalva maneuver are crucial for technical success and avoidance of complications. Conclusions: Endovascular treatment of varicoceles using NBCA glue is very effective and safe. PMID:23807881

  6. Endovascular Management of Thoracic Aortic Aneurysms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fattori, Rossella, E-mail: rossella.fattori@unibo.it; Russo, Vincenzo; Lovato, Luigi

    The overall survival of patients with thoracic aortic aneurysm (TAA) has improved significantly in the past few years. Endovascular treatment, proposed as an alternative to surgery, has been considered a therapeutic innovation because of its low degree of invasiveness, which allows the treatment of even high-surgical risk patients with limited complications and mortality. A major limitation is the lack of adequate evidence regarding long-term benefit and durability because follow-up has been limited to just a few years even in the largest series. The combination of endovascular exclusion with visceral branch revascularization for the treatment of thoraco-abdominal aortic aneurysms involving themore » visceral aorta has also been attempted. As an alternative, endografts with branches represent a technological evolution that allows treatment of complex anatomy. Even if only small numbers of patients and short follow-up are available, this technical approach, which has with limited mortality (<10%) and paraplegia rates, to expand endovascular treatment to TAA seems feasible. With improved capability to recognize proper anatomy and select clinical candidates, the choice of endovascular stent-graft placement may offer a strategy to optimize management and improve prognosis.« less

  7. Robot-assisted fenestrated endovascular aneurysm repair (FEVAR) using the Magellan system.

    PubMed

    Riga, Celia V; Bicknell, Colin D; Rolls, Alexander; Cheshire, Nicholas J; Hamady, Mohamad S

    2013-02-01

    A 67-year-old man underwent robot-assisted three-vessel fenestrated endovascular aneurysm repair (FEVAR) for a 7.3-cm juxtarenal aneurysm. The 6-F robotic catheter was manipulated from a remote workstation, away from the radiation source. Robotic cannulation of the left renal artery was achieved within 3 minutes. System setup time was 5 minutes. There were no postoperative complications. Computed tomography angiography performed at discharge and at 4-month follow-up confirmed target vessel patency with no evidence of an endoleak. Selective cannulation of target vessels during FEVAR using this novel technology is feasible. Endovascular robotics may have a role in simplifying complex endovascular tasks and potentially reducing radiation exposure to the operator. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  8. Signal quality of endovascular electroencephalography

    NASA Astrophysics Data System (ADS)

    He, Bryan D.; Ebrahimi, Mosalam; Palafox, Leon; Srinivasan, Lakshminarayan

    2016-02-01

    Objective, Approach. A growing number of prototypes for diagnosing and treating neurological and psychiatric diseases are predicated on access to high-quality brain signals, which typically requires surgically opening the skull. Where endovascular navigation previously transformed the treatment of cerebral vascular malformations, we now show that it can provide access to brain signals with substantially higher signal quality than scalp recordings. Main results. While endovascular signals were known to be larger in amplitude than scalp signals, our analysis in rabbits borrows a standard technique from communication theory to show endovascular signals also have up to 100× better signal-to-noise ratio. Significance. With a viable minimally-invasive path to high-quality brain signals, patients with brain diseases could one day receive potent electroceuticals through the bloodstream, in the course of a brief outpatient procedure.

  9. Strategies for managing aortoiliac occlusions: access, treatment and outcomes

    PubMed Central

    Clair, Daniel G; Beach, Jocelyn M

    2015-01-01

    Treatment of severe aortoiliac disease has dramatically evolved from a dependence on open aortobifemoral grafting to hybrid and endovascular only approaches. Open surgery has been the gold standard treatment of severe aortoiliac disease with excellent patency rates, but with increased length of stay and major complications. In contrast, endovascular interventions can successfully treat almost any lesion with decreased risk, compared to open surgery. Although primary patency rates remain inferior, secondary endovascular interventions are often minor procedures resulting in comparable long-term outcomes. The risks of renal insufficiency, embolization and access complications are not insignificant; however, most can be prevented or managed without significant clinical consequence. Endovascular therapies should be considered a first-line treatment option for all patients with aortoiliac disease, especially those with high-risk cardiovascular comorbidities. PMID:25907618

  10. Patient selection and perioperative outcomes of bypass and endovascular intervention as first revascularization strategy for infrainguinal arterial disease.

    PubMed

    Bodewes, Thomas C F; Darling, Jeremy D; Deery, Sarah E; O'Donnell, Thomas F X; Pothof, Alexander B; Shean, Katie E; Moll, Frans L; Schermerhorn, Marc L

    2018-01-01

    The optimal initial revascularization strategy remains uncertain for patients with peripheral arterial disease. The purpose of this study was to evaluate current nationwide selection and perioperative outcomes of patients undergoing bypass or endovascular intervention for infrainguinal disease in those with no prior ipsilateral revascularization. Patients undergoing nonemergent first-time infrainguinal revascularization were identified in the Targeted Vascular module of the National Surgical Quality Improvement Program (NSQIP) for 2011 to 2014 and stratified by symptom status (chronic limb-threatening ischemia [CLTI] or claudication). Patients treated with endovascular intervention were compared with those who underwent bypass. Multivariable logistic regression was used to evaluate current selection of patients and to establish independent associations between first-time procedures and postoperative outcomes. Of 5998 first-time infrainguinal revascularizations performed, 3193 were bypass procedures (63% for CLTI) and 2805 were endovascular interventions (64% for CLTI). Current patient characteristics associated with an endovascular-first approach as opposed to bypass-first in CLTI patients were age ≥80 years, tissue loss, nonsmoking, functional dependence, diabetes, dialysis, and tibial lesions, whereas age ≥80 years, nonwhite race, nonsmoking, diabetes, and tibial lesions were associated with an endovascular approach for claudication. In comparing first-time endovascular intervention with bypass, there was no difference in 30-day mortality in CLTI patients (univariate: 2.1% vs 2.2%; adjusted: odds ratio [OR], 0.7; 95% confidence interval [CI], 0.4-1.1) or claudication patients (0.3% vs 0.6%). Among CLTI patients, endovascular-first intervention was associated with lower rates of major adverse cardiovascular event (3.6% vs 4.7%; OR, 0.6; 95% CI, 0.4-0.9), surgical site infection (0.9% vs 7.7%; OR, 0.1; 95% CI, 0.1-0.2), bleeding (8.5% vs 17%; OR, 0.4; 95% CI, 0.3-0.5), unplanned reoperation (13% vs 17%; OR, 0.7; 95% CI, 0.5-0.8), and unplanned readmission (17% vs 18%; OR, 0.8; 95% CI, 0.7-0.9). Patients with claudication undergoing endovascular-first intervention also had lower rates of major adverse cardiovascular event (0.8% vs 1.6%; OR, 0.4; 95% CI, 0.2-0.95), surgical site infection (0.7% vs 6.6%; OR, 0.1; 95% CI, 0.04-0.2), bleeding (2.3% vs 6.0%; OR, 0.3; 95% CI, 0.2-0.5), unplanned reoperation (4.3% vs 6.6%; OR, 0.6; 95% CI, 0.4-0.9), and unplanned readmission (5.9% vs 9.0%; OR, 0.6; 95% CI, 0.4-0.8). Conversely, endovascular-first intervention was associated with a higher rate of secondary revascularizations within 30 days for CLTI (4.3% vs 3.1%; OR, 1.6; 95% CI, 1.04-2.3) but not for claudication (2.6% vs 1.9%; OR, 1.7; 95% CI, 0.9-3.4). An endovascular-first approach as a revascularization strategy for infrainguinal disease was associated with substantially lower early morbidity but not mortality, at the cost of higher rates of postoperative secondary revascularizations. As a national representation of first-time revascularizations, this study highlights the early endovascular perioperative benefit, although more robust long-term data are needed to adopt either one strategy or the other in select patients with peripheral arterial disease. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  11. Clinical Study of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) for Severe Pelvic Fracture and Intra Abdominal Hemorrhagic Shock using Continuous Vital Signs

    DTIC Science & Technology

    2016-03-01

    AWARD NUMBER: W81XWH-15-1-0025 TITLE: Clinical Study of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) for Severe Pelvic...Intra-Abdominal Hemorrhagic Shock 5b. GRANT NUMBER W81XWH-15-1-0025 Clinical Study of Resuscitative Endovascular Balloon Occlusion of the Aorta ...sites. Resuscitative balloon occlusion of the aorta (REBOA) has been clinically demonstrated to stop bleeding below the diaphragm. It has the potential

  12. Endovascular Treatment of Carotid-Internal Jugular Venous Fistula in a Bomb Blast Victim.

    PubMed

    Ashraf, Tariq; Khan, Navedullah; Yousaf, K M; Yaqub, Maha Zainab Z.

    2017-02-01

    Carotid-internal jugular venous fistula is one of the rarest presentations among victims of bomb blast injuries. Treatment of such fistula is open surgery with high mortality and morbidity. Endovascular treatment with covered stent seems to have an optimal result with low complications. We present a case report of a bomb blast victim having carotid-jugular venous fistula with hemodynamic compromise. The patient was successfully managed with endovascular graft stent. There was an optimal result with no immediate and long-term complications.

  13. A combined endovascular and open ''reverse hybrid'' technique for repair of complex juxtarenal inflammatory aortic aneurysms.

    PubMed

    Rigberg, David; Jimenez, Juan Carlos; Lawrence, Peter; Gelabert, Hugh

    2009-01-01

    Inflammatory abdominal aortic aneurysms (IAAA) can present significant challenges to surgeons, especially in the juxtarenal location where they may not be amenable to endovascular repair. The dense, inflammatory component of these lesions can encase adjacent structures including the duodenum, ureters, and inferior vena cava putting them at risk for injury during open exposure. We report a novel ''reverse hybrid'' technique using a combined endovascular and open approach for repair of large, juxtarenal IAAA's.

  14. Effect of short-term ε-aminocaproic acid treatment on patients undergoing endovascular coil embolization following aneurysmal subarachnoid hemorrhage.

    PubMed

    Malekpour, Mahdi; Kulwin, Charles; Bohnstedt, Bradley N; Radmand, Golnar; Sethia, Rishabh; Mendenhall, Stephen K; Weyhenmeyer, Jonathan; Hendricks, Benjamin K; Leipzig, Thomas; Payner, Troy D; Shah, Mitesh V; Scott, John; DeNardo, Andrew; Sahlein, Daniel; Cohen-Gadol, Aaron A

    2017-05-01

    OBJECTIVE Aneurysmal rebleeding before definitive obliteration of the aneurysm is a cause of mortality and morbidity. There are limited data on the role of short-term antifibrinolytic therapy among patients undergoing endovascular intervention. METHODS All consecutive patients receiving endovascular therapy for their ruptured saccular aneurysm at the authors' institution between 2000 and 2011 were included in this study. These patients underwent endovascular coiling of their aneurysm within 72 hours of admission. In patients receiving ε-aminocaproic acid (EACA), the EACA administration was continued until the time of the endovascular procedure. Complications and clinical outcomes of endovascular treatment after aneurysmal subarachnoid hemorrhage (aSAH) were compared between EACA-treated and untreated patients. RESULTS During the 12-year study period, 341 patients underwent endovascular coiling. Short-term EACA treatment was administered in 146 patients and was withheld in the other 195 patients. EACA treatment did not change the risk of preinterventional rebleeding in this study (OR 0.782, 95% CI 0.176-3.480; p = 0.747). Moreover, EACA treatment did not increase the rate of thromboembolic events. On the other hand, patients who received EACA treatment had a significantly longer duration of hospital stay compared with their counterparts who were not treated with EACA (median 19 days, interquartile range [IQR] 12.5-30 days vs median 14 days, IQR 10-23 days; p < 0.001). EACA treatment was associated with increased odds of shunt requirement (OR 2.047, 95% CI 1.043-4.018; p = 0.037) and decreased odds of developing cardiac complications (OR 0.138, 95% CI 0.031-0.604; p = 0.009) and respiratory insufficiency (OR 0.471, 95% CI 0.239-0.926; p = 0.029). Short-term EACA treatment did not affect the Glasgow Outcome Scale score at discharge, 6 months, or 1 year following discharge. CONCLUSIONS In this study, short-term EACA treatment in patients who suffered from aSAH and received endovascular aneurysm repair did not decrease the risk of preinterventional rebleeding or increase the risk of thrombotic events. EACA did not affect outcome. Randomized clinical trials are required to provide robust clinical recommendation on short-term use of EACA.

  15. Evolving strategies for the treatment of aortoenteric fistulas.

    PubMed

    Baril, Donald T; Carroccio, Alfio; Ellozy, Sharif H; Palchik, Eugene; Sachdev, Ulka; Jacobs, Tikva S; Marin, Michael L

    2006-08-01

    Aortoenteric fistulas (AEFs) are a rare but often fatal cause of gastrointestinal bleeding. Operative repair of AEF has been historically associated with extremely high morbidity and mortality. We reviewed our experience of open surgical and endovascular treatment of AEF to compare outcomes over a contemporaneous time period. Over a 9-year period between January 1997 and January 2006, 16 patients (11 men and 5 women) were diagnosed with and treated for AEFs. Seven patients underwent open surgical repair, and nine, with anatomically suitable lesions, underwent endovascular repair. The outcome after treatment of these patients was investigated for survival, perioperative complications, length of hospital stay, and long-term disposition. Three primary and 13 secondary AEFs were treated. The mean time from the initial aortic operation until AEF diagnosis was 5.9 years (range, 0.7-12.2 years) for patients with secondary AEFs. The overall 30-day mortality rate was 18.8%. One intraoperative death and one in-hospital death secondary to multisystem organ failure occurred in patients undergoing open repair. One in-hospital death related to persistent sepsis occurred in the endovascular group. The overall perioperative complication rate was 50.0%. Complications in the open group included sepsis, renal failure, bowel obstruction, and pancreatitis. Complications in the endovascular group were related to persistent sepsis. The mean in-hospital length of stay was significantly longer for patients undergoing open repair compared with endovascular repair (44.0 vs 19.4 days; P = .04). Four (80%) of five patients who were discharged from the hospital in the open group were placed in skilled nursing facilities, and seven (87.5%) of eight patients discharged in the endovascular group returned home. The median overall survival after hospital discharge was 23.1 months. There were no late aneurysm-related deaths or late deaths related to septic complications. Patients with AEFs have limited overall survival. Endovascular therapy offers an alternative to open surgical repair, seems to be associated with decreased perioperative morbidity and mortality and a shorter in-hospital stay, and allows for acceptable survival given the presence of coexisting medical comorbidities. Furthermore, endovascular repair provides a therapeutic option to control bleeding and allow for continued intervention in a stabilized setting.

  16. MR-guided endovascular interventions: a comprehensive review on techniques and applications.

    PubMed

    Kos, Sebastian; Huegli, Rolf; Bongartz, Georg M; Jacob, Augustinus L; Bilecen, Deniz

    2008-04-01

    The magnetic resonance (MR) guidance of endovascular interventions is probably one of the greatest challenges of clinical MR research. MR angiography is not only an imaging tool for the vasculature but can also simultaneously depict high tissue contrast, including the differentiation of the vascular wall and perivascular tissues, as well as vascular function. Several hurdles had to be overcome to allow MR guidance for endovascular interventions. MR hardware and sequence design had to be developed to achieve acceptable patient access and to allow real-time or near real-time imaging. The development of interventional devices, both applicable and safe for MR imaging (MRI), was also mandatory. The subject of this review is to summarize the latest developments in real-time MRI hardware, MRI, visualization tools, interventional devices, endovascular tracking techniques, actual applications and safety issues.

  17. Endovascular therapy of acute ischemic stroke: report of the Standards of Practice Committee of the Society of NeuroInterventional Surgery.

    PubMed

    Blackham, K A; Meyers, P M; Abruzzo, T A; Albuquerque, F C; Alberquerque, F C; Fiorella, D; Fraser, J; Frei, D; Gandhi, C D; Heck, D V; Hirsch, J A; Hsu, D P; Hussain, M Shazam; Jayaraman, M; Narayanan, S; Prestigiacomo, C; Sunshine, J L

    2012-03-01

    To summarize and classify the evidence for the use of endovascular techniques in the treatment of patients with acute ischemic stroke. Recommendations previously published by the American Heart Association (AHA) (Guidelines for the early management of adults with ischemic stroke (Circulation 2007) and Scientific statement indications for the performance of intracranial endovascular neurointerventional procedures (Circulation 2009)) were vetted and used as a foundation for the current process. Building on this foundation, a critical review of the literature was performed to evaluate evidence supporting the endovascular treatment of acute ischemic stroke. The assessment was based on guidelines for evidence based medicine proposed by the Stroke Council of the AHA and the University of Oxford, Centre for Evidence Based Medicine (CEBM). Procedural safety, technical efficacy and impact on patient outcomes were specifically examined.

  18. Duplex evaluation following femoropopliteal angioplasty and stenting: criteria and utility of surveillance.

    PubMed

    Baril, Donald T; Marone, Luke K

    2012-07-01

    Surveillance following lower extremity bypass, carotid endarterectomy, and endovascular aortic aneurysm repair has become the standard of care at most institutions. Conversely, surveillance following lower extremity endovascular interventions is performed somewhat sporadically in part because the duplex criteria for recurrent stenoses have been ill defined. It appears that duplex surveillance after peripheral endovascular interventions, as with conventional bypass, is beneficial in identifying recurrent lesions which may preclude failure and occlusion. In-stent stenosis following superficial femoral artery angioplasty and stenting can be predicted by both peak systolic velocity and velocity ratio data as measured by duplex ultrasound. Duplex criteria have been defined to determine both ≥50% in-stent stenosis and ≥80% in-stent stenosis. Although not yet well studied, it appears that applying these criteria during routine surveillance may assist in preventing failure of endovascular interventions.

  19. Hepatorenal revascularization enables EVAR repair on a patient with AAA and an ectopic right renal artery.

    PubMed

    Lazaris, A M; Moulakakis, K; Mantas, G; Poulou, K; Alexiou, E; Vasdekis, S; Geroulakos, G

    2018-06-07

    The last thirty years the endovascular repair (EVAR) has become the standard method of treatment of abdominal aortic aneurysms (AAA). Nevertheless, the method has limitations based mainly on the anatomic characteristics of the specific aneurysm. In these cases a combination of endovascular and open techniques can be used. We describe a case of a patient with an infrarenal AAA and an ectopic right renal artery emerging from within the aneurysm sac. The patient was treated with a combination of endovascular and open techniques. In particular, he underwent a hepatorenal revascularization followed by a standard EVAR procedure, with a successful final outcome. For the treatment of AAA disease, the combination of open and endovascular procedures can overcome difficulties where a standard EVAR cannot be an option. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Human Thiel-Embalmed Cadaveric Aortic Model with Perfusion for Endovascular Intervention Training and Medical Device Evaluation.

    PubMed

    McLeod, Helen; Cox, Ben F; Robertson, James; Duncan, Robyn; Matthew, Shona; Bhat, Raj; Barclay, Avril; Anwar, J; Wilkinson, Tracey; Melzer, Andreas; Houston, J Graeme

    2017-09-01

    The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.

  1. Predictive factors for cerebrovascular accidents after thoracic endovascular aortic repair.

    PubMed

    Mariscalco, Giovanni; Piffaretti, Gabriele; Tozzi, Matteo; Bacuzzi, Alessandro; Carrafiello, Giampaolo; Sala, Andrea; Castelli, Patrizio

    2009-12-01

    Cerebrovascular accidents are devastating and worrisome complications after thoracic endovascular aortic repair. The aim of this study was to determine cerebrovascular accident predictors after thoracic endovascular aortic repair. Between January 2001 and June 2008, 76 patients treated with thoracic endovascular aortic repair were prospectively enrolled. The study cohort included 61 men; mean age was 65.4 +/- 16.8 years. All patients underwent a specific neurologic assessment on an hourly basis postoperatively to detect neurologic deficits. Cerebrovascular accidents were diagnosed on the basis of physical examination, tomography scan or magnetic resonance imaging, or autopsy. Cerebrovascular accidents occurred in 8 (10.5%) patients, including 4 transient ischemic attack and 4 major strokes. Four cases were observed within the first 24-hours. Multivariable analysis revealed that anatomic incompleteness of the Willis circle (odds ratio [OR] 17.19, 95% confidence interval [CI] 2.10 to 140.66), as well as the presence of coronary artery disease (OR 6.86, 95 CI% 1.18 to 40.05), were independently associated with postoperative cerebrovascular accident development. Overall hospital mortality was 9.2%, with no significant difference for patients hit by cerebrovascular accidents (25.0% vs 7.3%, p = 0.102). Preexisting coronary artery disease, reflecting a severe diseased aorta and anomalies of Willis circle are independent cerebrovascular accident predictors after thoracic endovascular aortic repair procedures. A careful evaluation of the arch vessels and cerebral vascularization should be mandatory for patients suitable for thoracic endovascular aortic repair.

  2. TASC II and the endovascular management of infrainguinal disease.

    PubMed

    Lyden, Sean P; Smouse, H Bob

    2009-04-01

    The stratifications of aortoiliac, femoropopliteal, and infrapopliteal lesions included in the original comprehensive report of the TransAtlantic Inter-Society Consensus (TASC I) have been commonly used to formally characterize clinical trial populations and to channel investigative discussion among clinicians, while the associated treatment recommendations have become outdated as compared to current clinical practice. The TASC II report is an abbreviated update focusing on key areas of diagnosis and management of peripheral artery disease, with revised stratifications of aortoiliac and femoropopliteal lesions but not infrapopliteal disease. The consensus document keeps new lesion stratifications linked to the same structure of recommendations for initial treatment: endovascular for type A, endovascular (with qualifications) for type B, open surgical (with qualifications) for type C, and open surgical for type D. In general, each TASC II lesion category includes more severe disease than in TASC I, but the TASC II report does not recommend specific endovascular modalities for infrainguinal occlusive disease. We discuss how the new TASC II femoropopliteal lesion categories reflect current research outcomes and clinical practice, including summarized results from some more recent studies that have demonstrated the ability to treat by endovascular means increasingly complex femoropopliteal lesions that would actually be classifiable as type C. Noting that TASC II does not include a separate stratification of infrapopliteal lesions, as did TASC I, we review evidence of recent endovascular treatment of infrapopliteal lesions and contend that TASC classifications in this anatomical area should be upgraded.

  3. Computational modeling of an endovascular approach to deep brain stimulation

    NASA Astrophysics Data System (ADS)

    Teplitzky, Benjamin A.; Connolly, Allison T.; Bajwa, Jawad A.; Johnson, Matthew D.

    2014-04-01

    Objective. Deep brain stimulation (DBS) therapy currently relies on a transcranial neurosurgical technique to implant one or more electrode leads into the brain parenchyma. In this study, we used computational modeling to investigate the feasibility of using an endovascular approach to target DBS therapy. Approach. Image-based anatomical reconstructions of the human brain and vasculature were used to identify 17 established and hypothesized anatomical targets of DBS, of which five were found adjacent to a vein or artery with intraluminal diameter ≥1 mm. Two of these targets, the fornix and subgenual cingulate white matter (SgCwm) tracts, were further investigated using a computational modeling framework that combined segmented volumes of the vascularized brain, finite element models of the tissue voltage during DBS, and multi-compartment axon models to predict the direct electrophysiological effects of endovascular DBS. Main results. The models showed that: (1) a ring-electrode conforming to the vessel wall was more efficient at neural activation than a guidewire design, (2) increasing the length of a ring-electrode had minimal effect on neural activation thresholds, (3) large variability in neural activation occurred with suboptimal placement of a ring-electrode along the targeted vessel, and (4) activation thresholds for the fornix and SgCwm tracts were comparable for endovascular and stereotactic DBS, though endovascular DBS was able to produce significantly larger contralateral activation for a unilateral implantation. Significance. Together, these results suggest that endovascular DBS can serve as a complementary approach to stereotactic DBS in select cases.

  4. [Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses].

    PubMed

    Gizewski, E R; Weber, R; Forsting, M

    2011-02-01

    Approximately 6 - 50% of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12%, and up to 19% in the case of high-grade IAS (≥ 70%). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7% at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40% depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Advanced endografting techniques: snorkels, chimneys, periscopes, fenestrations, and branched endografts.

    PubMed

    Kansagra, Kartik; Kang, Joseph; Taon, Matthew-Czar; Ganguli, Suvranu; Gandhi, Ripal; Vatakencherry, George; Lam, Cuong

    2018-04-01

    The anatomy of aortic aneurysms from the proximal neck to the access vessels may create technical challenges for endovascular repair. Upwards of 30% of patients with abdominal aortic aneurysms (AAA) have unsuitable proximal neck morphology for endovascular repair. Anatomies considered unsuitable for conventional infrarenal stent grafting include short or absent necks, angulated necks, conical necks, or large necks exceeding size availability for current stent grafts. A number of advanced endovascular techniques and devices have been developed to circumvent these challenges, each with unique advantages and disadvantages. These include snorkeling procedures such as chimneys, periscopes, and sandwich techniques; "homemade" or "back-table" fenestrated endografts as well as manufactured, customized fenestrated endografts; and more recently, physician modified branched devices. Furthermore, new devices in the pipeline under investigation, such as "off-the-shelf" fenestrated stent grafts, branched stent grafts, lower profile devices, and novel sealing designs, have the potential of solving many of the aforementioned problems. The treatment of aortic aneurysms continues to evolve, further expanding the population of patients that can be treated with an endovascular approach. As the technology grows so do the number of challenging aortic anatomies that endovascular specialists take on, further pushing the envelope in the arena of aortic repair.

  6. Endovascular brain intervention and mapping in a dog experimental model using magnetically-guided micro-catheter technology.

    PubMed

    Kara, Tomas; Leinveber, Pavel; Vlasin, Michal; Jurak, Pavel; Novak, Miroslav; Novak, Zdenek; Chrastina, Jan; Czechowicz, Krzysztof; Belehrad, Milos; Asirvatham, Samuel J

    2014-06-01

    Despite the substantial progress that has been achieved in interventional cardiology and cardiac electrophysiology, endovascular intervention for the diagnosis and treatment of central nervous system (CNS) disorders such as stroke, epilepsy and CNS malignancy is still limited, particularly due to highly tortuous nature of the cerebral arterial and venous system. Existing interventional devices and techniques enable only limited and complicated access especially into intra-cerebral vessels. The aim of this study was to develop a micro-catheter magnetically-guided technology specifically designed for endovascular intervention and mapping in deep CNS vascular structures. Mapping of electrical brain activity was performed via the venous system on an animal dog model with the support of the NIOBE II system. A novel micro-catheter specially designed for endovascular interventions in the CNS, with the support of the NIOBE II technology, was able to reach safely deep intra-cerebral venous structures and map the electrical activity there. Such structures are not currently accessible using standard catheters. This is the first study demonstrating successful use of a new micro-catheter in combination with NIOBE II technology for endovascular intervention in the brain.

  7. Endovascular Neurosurgery: Personal Experience and Future Perspectives.

    PubMed

    Raymond, Jean

    2016-09-01

    From Luessenhop's early clinical experience until the present day, experimental methods have been introduced to make progress in endovascular neurosurgery. A personal historical narrative, spanning the 1980s to 2010s, with a review of past opportunities, current problems, and future perspectives. Although the technology has significantly improved, our clinical culture remains a barrier to methodologically sound and safe innovative care and progress. We must learn how to safely practice endovascular neurosurgery in the presence of uncertainty and verify patient outcomes in real time. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Endovascular repair of an iliac artery aneurysm in a patient with Ehlers-Danlos syndrome type IV.

    PubMed

    Tonnessen, Britt H; Sternbergh, W Charles; Mannava, Krishna; Money, Samuel R

    2007-01-01

    Ehlers-Danlos type IV (EDS-IV) is an inherited condition most notable for its associated vascular complications. Patients are prone to aneurysm formation, arterial dissection, and spontaneous vessel rupture. Intervention for the vascular pathology of EDS-IV carries high morbidity and mortality. We describe a case of a 57-year-old man with EDS-IV and an expanding iliac aneurysm who underwent successful endovascular repair with a stent-graft. Endovascular aneurysm repair is feasible and should be considered for patients with EDS-IV.

  9. Endovascular Repair of a Splenic Artery Aneurysm With Anomalous Origin From the Superior Mesenteric Artery.

    PubMed

    Jayakumar, Lalithapriya; Caputo, Francis J; Lombardi, Joseph V

    2017-04-01

    A 22 year old female with a history of recurrent abdominal pain was transferred to our institution with a diagnosis of splenic artery aneurysm identified on imaging. CT angiography of the abdomen and pelvis revealed a partially thrombosed 3.0 cm splenic artery aneurysm without signs of rupture and with an anomalous origin from the superior mesenteric artery. The patient was successfully treated with endovascular exclusion of the aneurysm. Herein we review some of the nuances of endovascular repair of splenic artery aneurysm.

  10. Successful Occlusion of a Ruptured Aortic Aneurysm Using the Amplatzer Vascular Plug: A Technical Note

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zander, Tobias, E-mail: tobiaszander@gmx.de; Baldi, Sebastian; Rabellino, Martin

    2011-02-15

    Ruptured abdominal aortic aneurysm is related with a 100% mortality rate if left untreated. Even with surgical intervention or endovascular repair, mortality is still extremely high. However, there are conditions in which neither open surgical aneurysm repair nor endovascular aneurysm repair can be considered a viable therapeutic option because of comorbidities or anatomic reasons. We report a case of successful endovascular treatment in a patient with ruptured abdominal aortic aneurysm by occluding the abdominal aneurysm using the Amplatzer Vascular Plug (AVP II).

  11. Endovascular Management of Acute Bleeding Arterioenteric Fistulas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leonhardt, Henrik; Mellander, Stefan; Snygg, Johan

    2008-05-15

    The objective of this study was to review the outcome of endovascular transcatheter repair of emergent arterioenteric fistulas. Cases of abdominal arterioenteric fistulas (defined as a fistula between a major artery and the small intestine or colon, thus not the esophagus or stomach), diagnosed over the 3-year period between December 2002 and December 2005 at our institution, were retrospectively reviewed. Five patients with severe enteric bleeding underwent angiography and endovascular repair. Four presented primary arterioenteric fistulas, and one presented a secondary aortoenteric fistula. All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascularmore » management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed immediate further open surgery. There were no procedure-related major complications. Mean hospital stay after the initial endovascular intervention was 19 days. Rebleeding occurred in four patients (80%) after a free interval of 2 weeks or longer. During the follow-up period three patients needed reintervention. The in-hospital mortality was 20% and the 30-day mortality was 40%. The midterm outcome was poor, due to comorbidities or rebleeding, with a mortality of 80% within 6 months. In conclusion, endovascular repair is an efficient and safe method to stabilize patients with life-threatening bleeding arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered. Patients with cancer may only need treatment for the acute bleeding episode, and an endovascular approach has the advantage of low morbidity.« less

  12. A leap forward in the endovascular management of acute basilar artery occlusion since the appearance of stent retrievers: a single-center comparative study.

    PubMed

    Fahed, Robert; Di Maria, Federico; Rosso, Charlotte; Sourour, Nader; Degos, Vincent; Deltour, Sandrine; Baronnet-Chauvet, Flore; Léger, Anne; Crozier, Sophie; Gabrieli, Joseph; Samson, Yves; Chiras, Jacques; Clarençon, Frédéric

    2017-05-01

    OBJECTIVE Contrary to acute ischemic stroke involving the anterior circulation, no randomized trial has yet demonstrated the safety and effectiveness of endovascular management in acute basilar artery occlusion (BAO). Recently developed thrombectomy devices, such as stentrievers and aspiration systems, have helped in improving the endovascular management of acute ischemic stroke. The authors sought to assess the impact of these devices in the endovascular treatment of acute BAO. METHODS A retrospective analysis of 34 consecutive patients treated in Pitié-Salpêtrière Hospital for acute BAO was carried out. All patients had undergone an endovascular procedure. In addition to the global results in terms of safety and effectiveness (recanalization rate and 3-month clinical outcome based on the modified Rankin Scale [mRS]), the authors aimed to determine if the patients treated with the most recently developed devices (i.e., the Solitaire stentriever or the ADAPT catheter) had better angiographic and clinical outcomes than those treated with older endovascular strategies. RESULTS The overall successful recanalization rate (thrombolysis in cerebral infarction score 2b-3) was 50% (17 of 34 patients). A good clinical outcome (mRS score 0-2 at 3-month follow-up) was achieved in 11 (32.3%) of 34 patients. The mortality rate at 3-month follow-up was 29.4% (10 of 34 patients). Patients treated with the Solitaire stentriever and the ADAPT catheter had a higher recanalization rate (12 [92.3%] of 13 patients vs 5 [23.8%] of 21 patients, p = 0.0002) and a shorter mean (± SD) procedure duration (88 ± 31 minutes vs 126 ± 58 minutes, p = 0.04) than patients treated with older devices. CONCLUSIONS The latest devices have improved the effectiveness of mechanical thrombectomy in acute BAO. Their use in further studies may help demonstrate a benefit in the endovascular management of acute BAO.

  13. Endovascular stent-graft repair of failed endovascular abdominal aortic aneurysm repair.

    PubMed

    Baril, Donald T; Silverberg, Daniel; Ellozy, Sharif H; Carroccio, Alfio; Jacobs, Tikva S; Sachdev, Ulka; Teodorescu, Victoria J; Lookstein, Robert A; Marin, Michael L

    2008-01-01

    Despite high initial technical success, the long-term durability of endovascular abdominal aortic aneurysm repair (EVAR) continues to be a concern. Following EVAR, patients can experience endoleaks, device migration, device fractures, or aneurysm growth that may require intervention. The purpose of this study was to review all patients treated with secondary endovascular devices at our institution for failed EVAR procedures. Over an 8-year period, 988 patients underwent EVAR, of whom 42 (4.3%) required secondary interventions involving placement of additional endovascular devices. Data regarding patient characteristics, aneurysm size, initial device type, time until failure, failure etiology, secondary interventions, and outcomes were reviewed. The mean time from initial operation until second operation was 34.1 months. Failures included type I endoleaks in 38 patients (90.5%), type III endoleaks in two patients (4.8%), and enlarging aneurysms without definite endoleaks in two patients (4.8%). The overall technical success rate for secondary repair was 92.9% (39/42). Perioperative complications occurred in nine patients (21.4%), including wound complications (n = 6), cerebrovascular accident (CVA) (n = 1), foot drop (n = 1), and death (n = 1). Mean follow-up following secondary repair was 16.4 months (range 1-50). Eighty-six percent of patients treated with aortouni-iliac devices had successful repairs compared to 45% of patients treated with proximal cuffs. Ten patients (23.8%) had persistent or recurrent type I or type III endoleaks following revision. Of these, four had tertiary interventions, including two patients who had additional devices placed. Failures following EVAR occur in a small but significant number of patients. When anatomically possible, endovascular revision offers a safe means of treating these failures. Aortouni-iliac devices appear to offer a more durable repair than the proximal cuff for treatment of proximal type I endoleaks. Midterm results indicate that these patients may require additional procedures but have a low rate of aneurysm-related mortality. Longer-term follow-up is necessary to determine the durability of these endovascular revisions.

  14. Endovascular Versus External Targeted Temperature Management for Patients With Out-of-Hospital Cardiac Arrest: A Randomized, Controlled Study.

    PubMed

    Deye, Nicolas; Cariou, Alain; Girardie, Patrick; Pichon, Nicolas; Megarbane, Bruno; Midez, Philippe; Tonnelier, Jean-Marie; Boulain, Thierry; Outin, Hervé; Delahaye, Arnaud; Cravoisy, Aurélie; Mercat, Alain; Blanc, Pascal; Santré, Charles; Quintard, Hervé; Brivet, François; Charpentier, Julien; Garrigue, Delphine; Francois, Bruno; Quenot, Jean-Pierre; Vincent, François; Gueugniaud, Pierre-Yves; Mira, Jean-Paul; Carli, Pierre; Vicaut, Eric; Baud, Frédéric J

    2015-07-21

    Targeted temperature management is recommended after out-of-hospital cardiac arrest. Whether advanced internal cooling is superior to basic external cooling remains unknown. The aim of this multicenter, controlled trial was to evaluate the benefit of endovascular versus basic surface cooling. Inclusion criteria were the following: age of 18 to 79 years, out-of-hospital cardiac arrest related to a presumed cardiac cause, time to return of spontaneous circulation <60 minutes, delay between return of spontaneous circulation and inclusion <240 minutes, and unconscious patient after return of spontaneous circulation and before the start of cooling. Exclusion criteria were terminal disease, pregnancy, known coagulopathy, uncontrolled bleeding, temperature on admission <30°C, in-hospital cardiac arrest, immediate need for extracorporeal life support or hemodialysis. Patients were randomized between 2 cooling strategies: endovascular femoral devices (Icy catheter, Coolgard, Zoll, formerly Alsius; n=203) or basic external cooling using fans, a homemade tent, and ice packs (n=197). The primary end point, that is, favorable outcome evaluated by survival without major neurological damage (Cerebral Performance Categories 1-2) at day 28, was not significantly different between groups (odds ratio, 1.41; 95% confidence interval, 0.93-2.16; P=0.107). Improvement in favorable outcome at day 90 in favor of the endovascular group did not reach significance (odds ratio, 1.51; 95% confidence interval, 0.96-2.35; P=0.07). Time to target temperature (33°C) was significantly shorter and target hypothermia was more strictly maintained in the endovascular than in the surface group (P<0.001). Minor side effects directly related to the cooling method were observed more frequently in the endovascular group (P=0.009). Despite better hypothermia induction and maintenance, endovascular cooling was not significantly superior to basic external cooling in terms of favorable outcome. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00392639. © 2015 American Heart Association, Inc.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nordon, Ian M., E-mail: inordon@sgul.ac.uk; Hinchliffe, Robert J.; Loftus, Ian M.

    Acute aortic syndrome (AAS) describes several life-threatening aortic pathologies. These include intramural hematoma, penetrating aortic ulcer, and acute aortic dissection (AAD). Advances in both imaging and endovascular treatment have led to an increase in diagnosis and improved management of these often catastrophic pathologies. Patients, who were previously consigned to medical management or high-risk open surgical repair, can now be offered minimally invasive solutions with reduced morbidity and mortality. Information from the International Registry of Acute Aortic Dissection (IRAD) database demonstrates how in selected patients with complicated AAD the 30-day mortality from open surgery is 17% and endovascular stenting is 6%.more » Despite these improvements in perioperative deaths, the risks of stroke and paraplegia remain with endovascular treatment (combined outcome risk 4%). The pathophysiology of each aspect of AAS is described. The best imaging techniques and the evolving role of endovascular techniques in the definitive management of AAS are discussed incorporating strategies to reduce perioperative morbidity.« less

  16. Endovascular interventions for central vein stenosis.

    PubMed

    Agarwal, Anil K

    2015-12-01

    Central vein stenosis is common because of the placement of venous access and cardiac intravascular devices and compromises vascular access for dialysis. Endovascular intervention with angioplasty and/or stent placement is the preferred approach, but the results are suboptimal and limited. Primary patency after angioplasty alone is poor, but secondary patency can be maintained with repeated angioplasty. Stent placement is recommended for quick recurrence or elastic recoil of stenosis. Primary patency of stents is also poor, though covered stents have recently shown better patency than bare metal stents. Secondary patency requires repeated intervention. Recanalization of occluded central veins is tedious and not always successful. Placement of hybrid graft-catheter with a combined endovascular surgical approach can maintain patency in many cases. In the presence of debilitating symptoms, palliative approach with endovascular banding or occlusion of the access may be necessary. Prevention of central vein stenosis is the most desirable strategy.

  17. Endovascular treatment of life-threatening pseudoaneurysm of the hepatic artery after pancreaticoduodenectomy.

    PubMed

    Narumi, Shunji; Hakamda, Kenichi; Toyoki, Yoshikazu; Noda, Hiroshi; Sato, Toshiyuki; Morohashi, Hajime; Mitsui, Toshihito; Yoshihara, Syuichi; Sasaki, Mutsuo

    2007-01-01

    Pseudoaneurysm is a life-threatening complication after pancreaticoduodenectomy. An endovascular covered stent was employed for treatment of pseudoaneurysm of the common hepatic artery after pancreaticoduodenectomy. A 77-year-old female underwent pylorus-preserving pancreaticoduodenectomy for lower bile duct cancer. She complained of hematochezia but upper gastrointestinal endoscopy did not find a bleeding source. Angiography was performed and pseudoaneurysm of the common hepatic artery was discovered. Since no collateral perfusion to the liver was detected, embolization of the common hepatic artery was considered to expose the patient to the danger of severe hepatic dysfunction. Successful exclusion of the pseudoaneurysm was completed with an endovascular covered stent. Inflow of the hepatic artery was secured and no hepatic dysfunction developed. Patency of the stent was confirmed at 5 months follow-up. An endovascular covered stent can be a feasible modality for selected cases of the hepatic arterial pseudoaneurysm.

  18. Successful Endovascular Treatment of Iliac Vein Compression (May-Thurner) Syndrome in a Pediatric Patient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Sener, Mesut

    2006-06-15

    A 10-year-old boy presented to our clinic with left lower extremity swelling present for 1 year with deterioration of symptoms during the prior month. Laboratory investigation for deep vein thrombosis was negative. Venography and computed tomography scan of the pelvis showed compression of the left common iliac vein by the right common iliac artery. A diagnosis of iliac vein compression syndrome was made. After venography, endovascular treatment was planned. The stenosis did not respond to balloon dilatation and a 12 mm Wallstent was placed with successful outcome. The patient's symptoms improved but did not resolve completely, probably due to amore » chronically occluded left superficial femoral vein that did not respond to endovascular recanalization. To the best of our knowledge, this is the first case of successful endovascular treatment of iliac vein compression syndrome with stent placement in a pediatric patient.« less

  19. Open Versus Endovascular or Hybrid Thoracic Aortic Aneurysm Repair.

    PubMed

    Clare, Ryan; Jorgensen, Julianne; Brar, Somjot S

    2016-10-01

    Thoracic aortic aneurysms are associated with significant morbidity and mortality. There are multiple underlying etiologies, including genetic abnormalities, that have important implications in their natural history. The variable histologic, anatomic, and clinical presentations necessitate careful consideration of available treatment options. Surgical repair of these aneurysms has been the mainstay of treatment; however, these approaches can carry a relatively high risk of morbidity and mortality. Endovascular approaches have now become first-line therapy for descending thoracic aneurysms, and with advancements in graft technology, endovascular approaches are being increasingly employed for hybrid repairs of the aortic arch and even the ascending aorta. However, to date, clinical outcomes from randomized trials and long-term follow-up are limited. As technology continues to advance, there is the potential for further integration of surgical and endovascular treatments so that patients have the best opportunity for a favorable outcome.

  20. Endovascular treatment of cerebral aneurysm after renal transplantation in polycystic kidney disease.

    PubMed

    Demartini, Zeferino; Galdino, Jennyfer; Koppe, Gelson L; Bignelli, Alexandre T; Francisco, Alexandre N; Gatto, Luana Am

    2018-06-01

    Background Patients with polycystic kidney disease have a higher prevalence of intracranial aneurysms and may progress to renal failure requiring transplantation. The endovascular treatment of intracranial aneurysms may improve prognosis, since rupture often causes premature death or disability, but the nephrotoxicity risk associated with contrast medium must be always considered in cases of renal impairment. Methods A 55-year-old female patient with polycystic kidney disease and grafted kidney associated with anterior communicant artery aneurysm was successfully treated by embolization. Results The renal function remained normal after the procedure. To the authors' knowledge, this is the first case of endovascular treatment of brain aneurysm in a transplanted patient reported in the medical literature. Conclusions The endovascular procedure in renal transplant patients is feasible and can be considered to treat this population. Further studies and cases are needed to confirm its safety.

  1. [Neuroimaging follow-up of cerebral aneurysms treated with endovascular techniques].

    PubMed

    Delgado, F; Saiz, A; Hilario, A; Murias, E; San Román Manzanera, L; Lagares Gomez-Abascal, A; Gabarrós, A; González García, A

    2014-01-01

    There are no specific recommendations in clinical guidelines about the best time, imaging tests, or intervals for following up patients with intracranial aneurysms treated with endovascular techniques. We reviewed the literature, using the following keywords to search in the main medical databases: cerebral aneurysm, coils, endovascular procedure, and follow-up. Within the Cerebrovascular Disease Group of the Spanish Society of Neuroradiology, we aimed to propose recommendations and an orientative protocol based on the scientific evidence for using neuroimaging to monitor intracranial aneurysms that have been treated with endovascular techniques. We aimed to specify the most appropriate neuroimaging techniques, the interval, the time of follow-up, and the best approach to defining the imaging findings, with the ultimate goal of improving clinical outcomes while optimizing and rationalizing the use of available resources. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.

  2. Comparative clinical effectiveness and cost effectiveness of endovascular strategy v open repair for ruptured abdominal aortic aneurysm: three year results of the IMPROVE randomised trial.

    PubMed

    2017-11-14

    Objective  To assess the three year clinical outcomes and cost effectiveness of a strategy of endovascular repair (if aortic morphology is suitable, open repair if not) versus open repair for patients with suspected ruptured abdominal aortic aneurysm. Design  Randomised controlled trial. Setting  30 vascular centres (29 in UK, one in Canada), 2009-16. Participants  613 eligible patients (480 men) with a clinical diagnosis of ruptured aneurysm, of whom 502 underwent emergency repair for rupture. Interventions  316 patients were randomised to an endovascular strategy (275 with confirmed rupture) and 297 to open repair (261 with confirmed rupture). Main outcome measures  Mortality, with reinterventions after aneurysm repair, quality of life, and hospital costs to three years as secondary measures. Results  The maximum follow-up for mortality was 7.1 years, with two patients in each group lost to follow-up by three years. After similar mortality by 90 days, in the mid-term (three months to three years) there were fewer deaths in the endovascular than the open repair group (hazard ratio 0.57, 95% confidence interval 0.36 to 0.90), leading to lower mortality at three years (48% v 56%), but by seven years mortality was about 60% in each group (hazard ratio 0.92, 0.75 to 1.13). Results for the 502 patients with repaired ruptures were more pronounced: three year mortality was lower in the endovascular strategy group (42% v 54%; odds ratio 0.62, 0.43 to 0.88), but after seven years there was no clear difference between the groups (hazard ratio 0.86, 0.68 to 1.08). Reintervention rates up to three years were not significantly different between the randomised groups (hazard ratio 1.02, 0.79 to 1.32); the initial rapid rate of reinterventions was followed by a much slower mid-term reintervention rate in both groups. The early higher average quality of life in the endovascular strategy versus open repair group, coupled with the lower mortality at three years, led to a gain in average quality adjusted life years (QALYs) at three years of 0.17 (95% confidence interval 0.00 to 0.33). The endovascular strategy group spent fewer days in hospital and had lower average costs of -£2605 (95% confidence interval -£5966 to £702) (about €2813; $3439). The probability that the endovascular strategy is cost effective was >90% at all levels of willingness to pay for a QALY gain. Conclusions  At three years, compared with open repair, an endovascular strategy for suspected ruptured abdominal aortic aneurysm was associated with a survival advantage, a gain in QALYs, similar levels of reintervention, and reduced costs, and this strategy was cost effective. These findings support the increasing use of an endovascular strategy, with wider availability of emergency endovascular repair. Trial registration  Current Controlled Trials ISRCTN48334791; ClinicalTrials NCT00746122. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. DRAGON score predicts functional outcomes in acute ischemic stroke patients receiving both intravenous tissue plasminogen activator and endovascular therapy.

    PubMed

    Wang, Arthur; Pednekar, Noorie; Lehrer, Rachel; Todo, Akira; Sahni, Ramandeep; Marks, Stephen; Stiefel, Michael F

    2017-01-01

    The DRAGON score, which includes clinical and computed tomographic (CT) scan parameters, predicts functional outcomes in ischemic stroke patients treated with intravenous tissue plasminogen activator (IV tPA). We assessed the utility of the DRAGON score in predicting functional outcome in stroke patients receiving both IV tPA and endovascular therapy. A retrospective chart review of patients treated at our institution from February 2009 to October 2015 was conducted. All patients with computed tomography angiography (CTA) proven large vessel occlusions (LVO) who underwent intravenous thrombolysis and endovascular therapy were included. Baseline DRAGON scores and modified Rankin Score (mRS) at the time of hospital discharge was calculated. Good outcome was defined as mRS ≤3. Fifty-eight patients with LVO of the anterior circulation were studied. The mean DRAGON score of patients on admission was 5.3 (range, 3-8). All patients received IV tPA and endovascular therapy. Multivariate analysis demonstrated that DRAGON scores ≥7 was associated with higher mRS ( P < 0.006) and higher mortality ( P < 0.0001) compared with DRAGON scores ≤6. Patients with DRAGON scores of 7 and 8 on admission had a mortality rate of 3.8% and 40%, respectively. The DRAGON score can help predict better functional outcomes in ischemic stroke patients receiving both IV tPA and endovascular therapy. This data supports the use of the DRAGON score in selecting patients who could potentially benefit from more invasive therapies such as endovascular treatment. Larger prospective studies are warranted to further validate these results.

  4. Combined Open and Endovascular Repair for Aortic Arch Pathology

    PubMed Central

    Kang, Woong Chol; Ahn, Tae Hoon; Lee, Kyung Hoon; Moon, Chan Il; Han, Seung Hwan; Park, Chul-Hyun; Park, Kook-Yang; Kang, Jin Mo; Kim, Jung Ho

    2010-01-01

    Background and Objectives We describe our experience with combined open and endovascular repair in patients who have aortic arch pathology. Subjects and Methods This study is a retrospective analysis of 7 patients who underwent combined open and endovascular repair for aortic arch pathology. Medical records and radiographic information were reviewed. Results A total of 7 consecutive patients (5 men, 71.4%) underwent thoracic stent graft implantation. The mean age was 59.9±16.7 years. The indication for endovascular repair was aneurysmal degeneration in 5 patients, and rupture or impending rupture in 2 patients. In all 7 cases, supra-aortic transposition of the great vessels was performed successfully. Stent graft implantation was achieved in all cases. Surgical exposure of the access vessel was necessary in 2 patients. A total of 9 stent grafts were implanted (3 stent grafts in one patient). The Seal thoracic and the Valiant endovascular stent graft were implanted in 6 patients and 1 patient, respectively. There were no post-procedure deaths or neurologic complications. In 2 patients, bleeding and injury of access vessel were noted after the procedure. Postoperative endoleak was noted in 1 patient. One patient died at 10 months after the procedure due to a newly developed ascending aortic dissection. No patients required secondary intervention during the follow-up period. The aortic diameter decreased in 4 patients. In 3 patients, including 1 patient with endoleak, there was no change in aortic diameter. Conclusion Our experience suggests that combined open and endovascular repair for aortic arch pathology is safe and effective, with few complications. PMID:20830254

  5. Endovascular embolization of carotid-cavernous fistulas: A pioneering experience in Peru

    PubMed Central

    Plasencia, Andres R.; Santillan, Alejandro

    2012-01-01

    Background: Endovascular embolization represents the method of choice for the treatment of carotid-cavernous fistulas (CCFs). Methods: We report our experience using the endovascular technique in 24 patients harboring 25 CCFs treated between October 1994 and April 2010, with an emphasis on the role of detachable balloons for the treatment of direct CCFs. Results: Of the 16 patients who presented with direct CCFs (Barrow Type A CCFs) (age range, 7–62 years; mean age, 34.3 years), 14 were caused by traumatic injury and 2 by a ruptured internal carotid artery (ICA) aneurysm. Eight patients (age range, 32–71 years; mean age, 46.5 years) presented with nine indirect CCFs (Barrow Types B, C, and D). The clinical follow-up after endovascular treatment ranged from 2 to 108 months (mean, 35.2 months). In two cases (8%), the endovascular approach failed. Symptomatic complications related to the procedure occurred in three patients (12.5%): transient cranial nerve palsy in two patients and a permanent neurological deficit in one patient. Detachable balloons were used in 13 out of 16 (81.3%) direct CCFs and were associated with a cure rate of 92.3%. Overall, the angiographic cure rate was obtained in 22 out of 25 (88%) fistulas. Patients presenting with III nerve palsy improved gradually between 1 day and 6 months after treatment. Good clinical outcomes [modified Rankin scale (mRS) ≤ 2] were observed in 22 out of 24 (91.6%) patients at last follow-up. Conclusions: Endovascular treatment using detachable balloons still constitutes a safe and effective method to treat direct carotid-cavernous fistulas. PMID:22363900

  6. Endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization.

    PubMed

    Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas

    2010-01-01

    This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, p<0.001) before endovascular intervention. Preoperative imaging by magnetic resonance tomography (MRT) in 8 patients, computed tomography (CT) venography in 3, conventional angiography in 6, and/or ultrasonography in 8, verified 15 brachiocephalic, 13 internal jugular, 3 superior caval, and/or 3 subclavian venous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.

  7. Endovascular Embolization of Intracranial Infectious Aneurysms in Patients Undergoing Open Heart Surgery Using n-Butyl Cyanoacrylate.

    PubMed

    Cheng-Ching, Esteban; John, Seby; Bain, Mark; Toth, Gabor; Masaryk, Thomas; Hui, Ferdinand; Hussain, Muhammad Shazam

    2017-03-01

    Mycotic aneurysms are a serious complication of infective endocarditis with increased risk of intracranial hemorrhage. Patients undergoing open heart surgery for valve repair or replacement are exposed to anticoagulants, increasing the risk of aneurysm bleeding. These patients may require endovascular or surgical aneurysm treatment prior to heart surgery, but data on this approach are scarce. Retrospective review of consecutive patients with infectious endocarditis and mycotic aneurysms treated endovascularly with Trufill n-butyl cyanoacrylate (n-BCA) at the Cleveland Clinic between January 2013 and December 2015. Nine patients underwent endovascular treatment of mycotic aneurysms with n-BCA (mean age of 39 years). On imaging, 4 patients had intracerebral hemorrhage, 2 had multiple embolic infarcts, and the rest had no imaging findings. Twelve mycotic aneurysms were detected (3 patients with 2 aneurysms). Seven aneurysms were in the M4 middle cerebral artery segment, 4 in the posterior cerebral artery distribution, and 1 in the callosomarginal branch. n-BCA was diluted in ethiodized oil (1:1 to 1:2). Embolization was achieved in a single rapid injection with immediate microcatheter removal. Complete aneurysm exclusion was achieved in all cases without complications. All patients underwent open heart surgery and endovascular embolization within a short interval, 2 with both procedures on the same day. There were no new hemorrhages after aneurysm embolization. Endovascular embolization of infectious intracranial aneurysms with liquid embolics can be performed successfully in critically ill patients requiring immediate open heart surgery and anticoagulation. Early embolization prior to and within a short interval from open heart surgery is feasible.

  8. Safety of low-dose aspirin in endovascular treatment for intracranial atherosclerotic stenosis.

    PubMed

    Ma, Ning; Xu, Ziqi; Mo, Dapeng; Gao, Feng; Gao, Kun; Sun, Xuan; Xu, Xiaotong; Liu, Lian; Song, Ligang; Wang, Tiejun; Zhao, Xingquan; Wang, Yilong; Wang, Yongjun; Miao, Zhongrong

    2014-01-01

    To evaluate the safety of low-dose aspirin plus clopidogrel versus high-dose aspirin plus clopidogrel in prevention of vascular risk within 90 days of duration of dual antiplatelet therapy in patients treated with intracranial endovascular treatment. From January 2012 to December 2013, this prospective and observational study enrolled 370 patients with symptomatic intracranial atherosclerotic stenosis of ≥70% with poor collateral undergoing intracranial endovascular treatment. Antiplatelet therapy consists of aspirin, at a low-dose of 100 mg or high-dose of 300 mg daily; clopidogrel, at a dose of 75 mg daily for 5 days before endovascular treatment. The dual antiplatelet therapy continued for 90 days after intervention. The study endpoints include acute thrombosis, subacute thrombosis, stroke or death within 90 days after intervention. Two hundred and seventy three patients received low-dose aspirin plus clopidogrel and 97 patients received high-dose aspirin plus clopidogrel before intracranial endovascular treatment. Within 90 days after intervention, there were 4 patients (1.5%) with acute thrombosis, 5 patients (1.8%) with subacute thrombosis, 17 patients (6.2%) with stroke, and 2 death (0.7%) in low-dose aspirin group, compared with no patient (0%) with acute thrombosis, 2 patient (2.1%) with subacute thrombosis, 6 patients (6.2%) with stroke, and 2 death (2.1%) in high-dose aspirin group, and there were no significant difference in all study endpoints between two groups. Low-dose aspirin plus clopidogrel is comparative in safety with high-dose aspirin plus clopidogrel within 90 days of duration of dual antiplatelet therapy in patients treated with intracranial endovascular treatment.

  9. Predictors of Reintervention After Endovascular Repair of Isolated Iliac Artery Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zayed, Hany A., E-mail: hany.zayed@gstt.nhs.uk; Attia, Rizwan; Modarai, Bijan

    2011-02-15

    The objective of this study was to identify factors predicting the need for reintervention after endovascular repair of isolated iliac artery aneurysm (IIAA). We reviewed prospectively collected database records of all patients who underwent endovascular repair of IIAA between 1999 and 2008. Detailed assessment of the aneurysms was performed using computed tomography angiography (CTA). Follow-up protocol included CTA at 3 months. If this showed no complication, then annual duplex scan was arranged. Multivariate analysis and analysis of patient survival and freedom from reintervention were performed using Kaplan-Meier life tables. Forty IIAAs (median diameter 44 mm) in 38 patients were treatedmore » (all men; median age 75 years), and median follow-up was 27 months. Endovascular repair of IIAA was required in 14 of 40 aneurysms (35%). The rate of type I endoleak was significantly higher with proximal landing zone (PLZ) diameter >30 mm in the aorta or >24 mm in the common iliac artery or distal landing zone (DLZ) diameter >24 mm (P = 0.03, 0.03, and 0.0014, respectively). Reintervention rate (RR) increased significantly with increased diameter or decreased length of PLZ; increased DLZ diameter; and endovascular IIAA repair (P = 0.005, 0.005, 0.02, and 0.02 respectively); however, RR was not significantly affected by length of PLZ or DLZ. Freedom-from-reintervention was 97, 93, and 86% at 12, 24, and 108 months. There was no in-hospital or aneurysm-related mortality. Endovascular IIAA repair is a safe treatment option. Proper patient selection is essential to decrease the RR.« less

  10. Endovascular stent grafting of thoracic aortic aneurysms: technological advancements provide an alternative to traditional surgical repair.

    PubMed

    Jones, Lauren E Beste

    2005-01-01

    The use of endovascular stent grafts is a leading technological advancement in the treatment of thoracic aortic aneurysms, and is being trialed in the United States as an alternative to medical management and traditional surgical repair. Aortic stent grafts, initially used only for abdominal aortic aneurysms, have been used for over 10 years in Europe and are currently under United States Food and Drug Administration investigation for the treatment of chronic and acute aortic aneurysms. Diseases of the thoracic aorta are often present in high-risk individuals, and, as a result, there is a high morbidity and mortality rate associated with both medical and surgical management of these patients. The development and refinement of endovascular approaches have the potential to decrease the need for traditional surgical repair, especially in high-risk populations such as the elderly and those with multiple comorbidities. Endovascular technology for thoracic repair has only been used in Europe for the last 10 years, with no long-term outcomes available; however, preliminary research demonstrates favorable early and midterm outcomes showing that endovascular stent graft placement to exclude the dilated, dissected, or ruptured aorta is both technically feasible and safe for patients. The article highlights the historical perspective of endovascular stent grafting as well as a description of patient selection, the operative procedure, benefits, risks, and unresolved issues pertaining to the procedure. A brief review of aneurysm and dissection pathophysiology and management is provided, as well as postoperative management for acute care nurses and recommendations for clinical practice.

  11. In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease

    PubMed Central

    Ter Mors, Thijs G; Slump, Cornelis H; Geelkerken, Robert H; Holewijn, Suzanne; Reijnen, Michel MPJ

    2017-01-01

    Objectives Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcation configuration in vivo. Methods Post-operative computed tomographic data and patient demographics from 11 covered endovascular reconstruction of the aortic bifurcation and 11 matched kissing stent patients were included. A free hand region of interest and ellipse fitting method were applied to determine mismatch areas and volumes. Conformation of the stents to the vessel wall was expressed using the D-ratio. Results Patients were mostly treated for Rutherford category 2 and 3 (64%) with a lesion classification of TASC C and D in 82%. Radial mismatch area and volume for the covered endovascular reconstruction of the aortic bifurcation group was significantly lower compared to the kissing stent configuration (P < 0.05). The D-ratio did not significantly differ between groups. Measurements were performed with good intra-class correlation. There were no significant differences in the post-procedural aortoiliac anatomy. Conclusions The present study shows that radial mismatch exists in vivo and that large differences in mismatch exist, in favour of the covered endovascular reconstruction of the aortic bifurcation configuration. Future research should determine if the decreased radial mismatch results in improved local flow profiles and subsequent clinical outcome. PMID:28530484

  12. In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease.

    PubMed

    Groot Jebbink, Erik; Ter Mors, Thijs G; Slump, Cornelis H; Geelkerken, Robert H; Holewijn, Suzanne; Reijnen, Michel Mpj

    2017-12-01

    Objectives Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcation configuration in vivo. Methods Post-operative computed tomographic data and patient demographics from 11 covered endovascular reconstruction of the aortic bifurcation and 11 matched kissing stent patients were included. A free hand region of interest and ellipse fitting method were applied to determine mismatch areas and volumes. Conformation of the stents to the vessel wall was expressed using the D-ratio. Results Patients were mostly treated for Rutherford category 2 and 3 (64%) with a lesion classification of TASC C and D in 82%. Radial mismatch area and volume for the covered endovascular reconstruction of the aortic bifurcation group was significantly lower compared to the kissing stent configuration ( P < 0.05). The D-ratio did not significantly differ between groups. Measurements were performed with good intra-class correlation. There were no significant differences in the post-procedural aortoiliac anatomy. Conclusions The present study shows that radial mismatch exists in vivo and that large differences in mismatch exist, in favour of the covered endovascular reconstruction of the aortic bifurcation configuration. Future research should determine if the decreased radial mismatch results in improved local flow profiles and subsequent clinical outcome.

  13. Endovascular Repair of a Traumatic Axillary Pseudoaneurysm Following Anterior Shoulder Dislocation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stahnke, Michaela; Duddy, Martin J.

    2006-04-15

    Pseudoaneurysms due to musculoskeletal trauma are rare and comprise less than 2% of all pseudoaneurysms. We report a case of axillary pseudoaneurysm following anterior dislocation of the shoulder. The patient was successfully treated by endovascular intervention.

  14. Recanalization and clinical outcome of occlusion sites at baseline CT angiography in the Interventional Management of Stroke III trial.

    PubMed

    Demchuk, Andrew M; Goyal, Mayank; Yeatts, Sharon D; Carrozzella, Janice; Foster, Lydia D; Qazi, Emmad; Hill, Michael D; Jovin, Tudor G; Ribo, Marc; Yan, Bernard; Zaidat, Osama O; Frei, Donald; von Kummer, Rüdiger; Cockroft, Kevin M; Khatri, Pooja; Liebeskind, David S; Tomsick, Thomas A; Palesch, Yuko Y; Broderick, Joseph P

    2014-10-01

    To use baseline computed tomographic (CT) angiography to analyze imaging and clinical end points in an Interventional Management of Stroke III cohort to identify patients who would benefit from endovascular stroke therapy. The primary clinical end point was 90-day dichotomized modified Rankin Scale (mRS) score. Secondary end points were 90-day mRS score distribution and 24-hour recanalization. Prespecified subgroup was baseline proximal occlusions (internal carotid, M1, or basilar arteries). Exploratory analyses were subsets with any occlusion and specific sites of occlusion (two-sided α = .01). Of 656 subjects, 306 (47%) underwent baseline CT angiography or magnetic resonance angiography. Of 306, 282 (92%) had arterial occlusions. At baseline CT angiography, proximal occlusions (n = 220) demonstrated no difference in primary outcome (41.3% [62 of 150] endovascular vs 38% [27 of 70] intravenous [IV] tissue-plasminogen activator [tPA]; relative risk, 1.07 [99% confidence interval: 0.67, 1.70]; P = .70); however, 24-hour recanalization rate was higher for endovascular treatment (n = 167; 84.3% [97 of 115] endovascular vs 56% [29 of 52] IV tPA; P < .001). Exploratory subgroup analysis for any occlusion at baseline CT angiography did not demonstrate significant differences between endovascular and IV tPA arms for primary outcome (44.7% [85 of 190] vs 38% [35 of 92], P = .29), although ordinal shift analysis of full mRS distribution demonstrated a trend toward more favorable outcome (P = .011). Carotid T- or L-type occlusion (terminal internal carotid artery [ICA] with M1 middle cerebral artery and/or A1 anterior cerebral artery involvement) or tandem (extracranial or intracranial) ICA and M1 occlusion subgroup also showed a trend favoring endovascular treatment over IV tPA alone for primary outcome (26% [12 of 46] vs 4% [one of 23], P = .047). Significant differences were identified between treatment arms for 24-hour recanalization in proximal occlusions; carotid T- or L-type and tandem ICA and M1 occlusions showed greater recanalization and a trend toward better outcome with endovascular treatment. Vascular imaging should be mandated in future endovascular trials to identify such occlusions. Online supplemental material is available for this article. © RSNA, 2014.

  15. Endovascular Approach for Management of Bullet Embolization to the Heart.

    PubMed

    Mojtahedi, Alireza; Contractor, Sohail; Kisza, Piotr S

    2018-05-01

    Bullet embolization to the right heart through the vasculature is seen infrequently in cases presenting with penetrating trauma. Patients with unstable hemodynamic status are managed operatively. For a patient with stable hemodynamic parameters, diagnostic evaluation such as computed tomography angiogram, echocardiogram, or angiography could be performed to select the best treatment option. Endovascular treatment is employed infrequently in these cases but can be a viable option for select patients. We present a case of a bullet embolus to the right ventricle treated successfully with endovascular approach and discuss the technical aspects of this approach.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palena, Luis Mariano, E-mail: marianopalena@hotmail.com; Cester, Giacomo; Manzi, Marco

    In-stent reocclusion is a frequent complication of endovascular treatment and stenting, especially in the superficial femoral artery. Neointimal hyperplasia is the main cause of this problem, but in many cases, it occurs as a result of the presence of stent strut fractures. The two treatment options are endovascular and surgical intervention. The effectiveness of endovascular interventions in patients with critical limb ischemia has been well established, but in some cases, crossing the occluded stent is difficult. We describe a new technique to recanalize long in-stent superficial femoral artery occlusions characterized by direct stent puncture, followed by retrograde-antegrade recanalization after antegrademore » failures.« less

  17. Endovascular treatment of isolated systemic arterial supply to normal lung with coil and glue embolisation.

    PubMed

    Anil, G; Taneja, M; Tan, A-G-S

    2012-04-01

    Surgery is the standard treatment for the extremely rare pathology of isolated anomalous systemic arterial supply to normal lung (ISSNL). We describe our experience with this anomaly in a 29-year-old male presenting with recurrent haemoptysis that was successfully treated with a combination of metallic coils and cyanoacrylate glue. In addition to contributing to the extremely limited data on endovascular therapeutic options in ISSNL, we also intend to raise the awareness among endovascular therapists of the need to be cautious ofand preserve the radiculomedullary/pial branches arising from an anomalous artery before embolising it.

  18. Role of Interventional Radiology in the Emergent Management of Acute Upper Gastrointestinal Bleeding

    PubMed Central

    Navuluri, Rakesh; Patel, Jay; Kang, Lisa

    2012-01-01

    Approximately 100,000 cases of upper gastrointestinal bleeding (UGIB) require inpatient admission annually in the United States. When medical management and endoscopic therapy are inadequate, endovascular intervention can be lifesaving. These emergent situations highlight the importance of immediate competence of the interventional radiologist in the preangiographic evaluation as well as the endovascular treatment of UGIB. We describe a case of UGIB managed with endovascular embolization and detail the angiographic techniques used. The case description is followed by a detailed discussion of the treatment approach to UGIB, with attention to both nonvariceal and variceal algorithms. PMID:23997408

  19. Endovascular treatment of a postlaminectomy arteriovenous fistula. A case report.

    PubMed

    Ventura, M; Rivellini, C; Saracino, G; Mastromarino, A; Spartera, C; Zannetti, S

    2002-08-01

    We report a case of iliac arteriovenous fistula (AVF) following disk surgery. A 51-year-old woman underwent hemilaminectomy for a slipped disk. Two weeks after surgery the patient experienced dyspnea and oedema of the lower limbs. Presence of a systolic murmur on the cardiac floor and on the abdomen was detected and abdomen CT scan which evidenced a AVF between the right common iliac artery and vein. The lesion, confirmed by angiography, was successfully treated with the endovascular technique. The endovascular technique appears to be a valid alternative to the traditional surgical treatment of postlaminectomy AVF.

  20. Endovascular Treatment of a Carotid Dissecting Pseudoaneurysm in a Patient with Ehlers-Danlos Syndrome Type IV with Fatal Outcome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, Siok Ping, E-mail: siokpinglim@yahoo.co.uk; Duddy, Martin J.

    2008-01-15

    We present a patient with Ehlers-Danlos syndrome type IV (EDS IV) with a carotid dissecting pseudoaneurysm causing severe carotid stenosis. This lesion was treated endovascularly. Unfortunately, the patient died of remote vascular catastrophes (intracranial hemorrhage and abdominal aortic rupture). This unique case illustrates the perils of endovascular treatment of EDS IV patients and the need for preoperative screening for concomitant lesions. It also shows that a dissecting pseudoaneurysm can feasibly be treated with a covered stent and that closure is effective using Angioseal in patients with EDS IV.

  1. Endovascular treatment of ruptured true posterior communicating artery aneurysms.

    PubMed

    Yang, Yonglin; Su, Wandong; Meng, Qinghai

    2015-01-01

    Although true posterior communicating artery (PCoA) aneurysms are rare, they are of vital importance. We reviewed 9 patients with this fatal disease, who were treated with endovascular embolization, and discussed the meaning of endovascular embolization for the treatment of true PCoA aneurysms. From September 2006 to May 2012, 9 patients with digital substraction angiography (DSA) confirmed true PCoA aneurysms were treated with endovascular embolization. Patients were followed-up with a minimal duration of 17 months and assessed by Glasgow Outcome Scale (GOS) score. All the patients presented with spontaneous subarachnoid hemorrhage from the ruptured aneurysms. The ratio of males to females was 1:2, and the average age of onset was 59.9 (ranging from 52 to 72) years. The preoperative Hunt-Hess grade scores were I to III. All patients had recovered satisfactorily. No permanent neurological deficits were left. Currently, endovascular embolization can be recommended as the top choice for the treatment of most true PCoA aneurysms, due to its advanced technique, especially the application of the stent-assisted coiling technique, combined with its advantage of mininal invasiveness and quick recovery. However, the choice of treatment methods should be based on the clinical and anatomical characteristics of the aneurysm and the skillfulness of the surgeon.

  2. An Alternative Approach for Treating a Type Ia Endoleak after Conventional EVAR Using the Nellix Endovascular Aneurysm Sealing.

    PubMed

    Martinelli, Ombretta; Fresilli, Mauro; Irace, Luigi; Venosi, Salvatore; Jabbour, Jihad; Picone, Veronica; Maruca, Debora; Di Girolamo, Alessia; Gossetti, Bruno

    2018-05-01

    To report the use of a Nellix endovascular aneurysm sealing (EVAS) device, to successfully treat a type Ia endoleak (EL) after an endovascular aortic repair (EVAR). A 70-year-old man was diagnosed with a 90-mm aortic aneurysm, suspicious for being inflammatory. It was initially treated successfully, with a Medtronic Endurant (Medtronic, Minneapolis, MN, USA). Five years after the index endovascular repair, an asymptomatic type Ia EL was detected on duplex ultrasound and computed tomographic angiogram. Other endovascular solutions in the form of proximal cuff, chimney was considered difficult to execute due to challenges in planning, manipulation, and renal cannulation caused by the short proximal sealing zone above the existing stent graft and the constraints of the previous endograft. Thus, a relining of the previous endoprothesis was performed using the Nellix system (Endologix, Inc., Irvine, CA, USA). One-year follow-up imaging demonstrated successful resolution of the EL and persistent sealing of the Nellix device. Nellix EVAS system can be an alternative and safe option for relining a stent graft with a type Ia EL. Nellix platform can be added to the clinician's armamentarium for treating type Ia EL after conventional EVAR of infrarenal abdominal aortic aneurysm (AAA). Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Standards for Endovascular Neurosurgical Training and Certification of the Society of Korean Endovascular Neurosurgeons 2013

    PubMed Central

    Shin, Dong-Seong; Park, Sukh-Que; Kang, Hyun-Seung; Yoon, Seok-Mann; Cho, Jae-Hoon; Lim, Dong-Jun; Baik, Min-Woo; Kwon, O Ki

    2014-01-01

    The need for standard endovascular neurosurgical (ENS) training programs and certification in Korea cannot be overlooked due to the increasing number of ENS specialists and the expanding ENS field. The Society of Korean Endovascular Neurosurgeons (SKEN) Certification Committee has prepared training programs and certification since 2010, and the first certificates were issued in 2013. A task force team (TFT) was organized in August 2010 to develop training programs and certification. TFT members researched programs and systems in other countries to develop a program that best suited Korea. After 2 years, a rough draft of the ENS training and certification regulations were prepared, and the standard training program title was decided. The SKEN Certification Committee made an official announcement about the certification program in March 2013. The final certification regulations comprised three major parts: certified endovascular neurosurgeons (EN), certified ENS institutions, and certified ENS training institutions. Applications have been evaluated and the results were announced in June 2013 as follows: 126 members received EN certification and 55 hospitals became ENS-certified institutions. The SKEN has established standard ENS training programs together with a certification system, and it is expected that they will advance the field of ENS to enhance public health and safety in Korea. PMID:24851145

  4. Comparação entre cirurgia aberta e endovascular no tratamento do aneurisma da artéria poplítea: uma revisão

    PubMed Central

    Gonçalves, Ana Fernanda Fagundes; Pelek, Carlos Augusto; Nogueira, Lorena Slusarz; de Carvalho, Renan Francisco; Stumpf, Matheo Augusto Morandi; Gomes, Ricardo Zanetti; Kluthcovsky, Ana Claudia Garabeli Cavalli

    2018-01-01

    Resumo Os aneurismas de artéria poplítea correspondem a 70% dos aneurismas periféricos e o tratamento é cirúrgico, com controvérsias sobre os resultados da via endovascular. Este estudo objetivou realizar uma revisão da literatura sobre a comparação entre cirurgia aberta e endovascular no tratamento dos aneurismas da artéria poplítea. A pesquisa foi realizada utilizando os termos apropriados nos portais de periódicos LILACS e MEDLINE, com a seleção de 15 artigos. Um total de 5.166 procedimentos cirúrgicos foram comparados, sendo 3.930 cirurgias abertas e 1.236 cirurgias endovasculares. A cirurgia aberta com bypass venoso continua sendo o padrão-ouro. A cirurgia endovascular apresenta menor tempo de internação e é uma opção viável em pacientes eletivos, com baixa expectativa de vida, alto risco cirúrgico, comorbidades e mais idosos, desde que tenham anatomia favorável para o procedimento. Contudo, são necessários estudos de longo prazo para estabelecer os reais benefícios e indicações das duas técnicas, como o ensaio clínico randomizado controlado.

  5. Endovascular Management of Acute Embolic Occlusion of the Superior Mesenteric Artery: A 12-Year Single-Centre Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raupach, J., E-mail: janraupach@seznam.cz; Lojik, M., E-mail: miroslav.lojik@fnhk.cz; Chovanec, V., E-mail: chovanec.v@seznam.cz

    2016-02-15

    PurposeRetrospective evaluation of 12-year experience with endovascular management of acute mesenteric ischemia (AMI) due to embolic occlusion of the superior mesenteric artery (SMA).Materials and methodsFrom 2003 to 2014, we analysed the in-hospital mortality of 37 patients with acute mesenteric embolism who underwent primary endovascular therapy with subsequent on-demand laparotomy. Transcatheter embolus aspiration was used in all 37 patients (19 women, 18 men, median age 76 years) with embolic occlusion of the SMA. Adjunctive local thrombolysis (n = 2) and stenting (n = 2) were also utilised.ResultsWe achieved complete recanalization of the SMA stem in 91.9 %. One patient was successfully treated by surgical embolectomy due tomore » a failed endovascular approach. Subsequent exploratory laparotomy was performed in 73.0 % (n = 27), and necrotic bowel resection in 40.5 %. The total in-hospital mortality was 27.0 %.ConclusionPrimary endovascular therapy for acute embolic SMA occlusion with on-demand laparotomy is a recommended algorithm used in our centre to treat SMA occlusion. This combined approach for the treatment of AMI is associated with in-hospital mortality rate of 27.0 %.« less

  6. Cardiovascular and Interventional Radiological Society of Europe Guidelines on Endovascular Treatment in Aortoiliac Arterial Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossi, Michele, E-mail: michele.rossi@uniroma1.it; Iezzi, Roberto, E-mail: roberto.iezzi.md@gmail.com

    2013-11-06

    PurposeThese guidelines are intended for use in assessing the standard for technical success and safety in aorto-iliac percutaneous endovascular interventions.MethodsAny recommendation contained in the text comes from the highest level and extension of literature review available to date.ResultsThe success of endovascular procedures is strictly related to an accurate planning based mainly on CT- or MR-angiography. TASC II A through C lesions have an endovascular-first option Pre-procedure ASA antiplatelet therapy is advisable in all cases. The application of stents improves the immediate hemodynamic and most likely long-term clinical results. Cumulative mean complication rate is 7.51 % according to the most relevant literature.more » Most of the complications can be managed by means of percutaneous techniques.ConclusionThe design and quality of devices, as well as the easy and accuracy of performing these procedures, have improved over the last decades, leading to the preferential treatment of aorto-iliac steno-obstructive disease via endovascular means, often as first-line therapy, with high technical success rate and low morbidity. This is mirrored by the decreasing number of patients undergoing surgical grafts over the last years with patency, limb salvage, and survival rates equivalent to open reconstruction.« less

  7. Dual wire welding torch and method

    DOEpatents

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  8. Self-Reacting Friction Stir Welding for Aluminum Alloy Circumferential Weld Applications

    NASA Technical Reports Server (NTRS)

    Bjorkman, Gerry; Cantrell, Mark; Carter, Robert

    2003-01-01

    Friction stir welding is an innovative weld process that continues to grow in use, in the commercial, defense, and space sectors. It produces high quality and high strength welds in aluminum alloys. The process consists of a rotating weld pin tool that plasticizes material through friction. The plasticized material is welded by applying a high weld forge force through the weld pin tool against the material during pin tool rotation. The high weld forge force is reacted against an anvil and a stout tool structure. A variation of friction stir welding currently being evaluated is self-reacting friction stir welding. Self-reacting friction stir welding incorporates two opposing shoulders on the crown and root sides of the weld joint. In self-reacting friction stir welding, the weld forge force is reacted against the crown shoulder portion of the weld pin tool by the root shoulder. This eliminates the need for a stout tooling structure to react the high weld forge force required in the typical friction stir weld process. Therefore, the self-reacting feature reduces tooling requirements and, therefore, process implementation costs. This makes the process attractive for aluminum alloy circumferential weld applications. To evaluate the application of self-reacting friction stir welding for aluminum alloy circumferential welding, a feasibility study was performed. The study consisted of performing a fourteen-foot diameter aluminum alloy circumferential demonstration weld using typical fusion weld tooling. To accomplish the demonstration weld, weld and tack weld development were performed and fourteen-foot diameter rings were fabricated. Weld development consisted of weld pin tool selection and the generation of a process map and envelope. Tack weld development evaluated gas tungsten arc welding and friction stir welding for tack welding rings together for circumferential welding. As a result of the study, a successful circumferential demonstration weld was produced leading the way for future circumferential weld implementation.

  9. Long-term risk of carotid restenosis in patients randomly assigned to endovascular treatment or endarterectomy in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    PubMed

    Bonati, Leo H; Ederle, Jörg; McCabe, Dominick J H; Dobson, Joanna; Featherstone, Roland L; Gaines, Peter A; Beard, Jonathan D; Venables, Graham S; Markus, Hugh S; Clifton, Andrew; Sandercock, Peter; Brown, Martin M

    2009-10-01

    In the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS), early recurrent carotid stenosis was more common in patients assigned to endovascular treatment than it was in patients assigned to endarterectomy (CEA), raising concerns about the long-term effectiveness of endovascular treatment. We aimed to investigate the long-term risks of restenosis in patients included in CAVATAS. 413 patients who were randomly assigned in CAVATAS and completed treatment for carotid stenosis (200 patients had endovascular treatment and 213 patients had endarterectomy) had prospective clinical follow-up at a median of 5 years and carotid duplex ultrasound at a median of 4 years. We investigated the cumulative long-term incidence of carotid restenosis after endovascular treatment and endarterectomy, the effect of the use of stents on restenosis after endovascular treatment, risk factors for the development of restenosis, and the effect of carotid restenosis on the risk of recurrent cerebrovascular events. Analysis was by intention to treat. This study is registered, number ISRCTN01425573. Severe carotid restenosis (>or=70%) or occlusion occurred significantly more often in patients in the endovascular arm than in patients in the endarterectomy arm (adjusted hazard ratio [HR] 3.17, 95% CI 1.89-5.32; p<0.0001). The estimated 5-year incidence of restenosis was 30.7% in the endovascular arm and 10.5% in the endarterectomy arm. Patients in the endovascular arm who were treated with a stent (n=50) had a significantly lower risk of developing restenosis of 70% or greater compared with those treated with balloon angioplasty alone (n=145; HR 0.43, 0.19-0.97; p=0.04). Current smoking or a history of smoking was a predictor of restenosis of 70% or more (2.32, 1.19-4.54; p=0.01) and the early finding of moderate stenosis (50-69%) up to 60 days after treatment was associated with the risk of progression to restenosis of 70% or more (3.76, 1.88-7.52; p=0.0002). The composite endpoint of ipsilateral non-perioperative stroke or transient ischaemic attack occurred more often in patients in whom restenosis of 70% or more was diagnosed in the first year after treatment compared with patients without restenosis of 70% or more (5-year incidence 23%vs 11%; HR 2.18, 1.04-4.54; p=0.04), but the increase in ipsilateral stroke alone was not significant (10%vs 5%; 1.67, 0.54-5.11). Restenosis is about three times more common after endovascular treatment than after endarterectomy and is associated with recurrent ipsilateral cerebrovascular symptoms; however, the risk of recurrent ipsilateral stroke is low. Further data are required from on-going trials of stenting versus endarterectomy to ascertain whether long-term ultrasound follow-up is necessary after carotid revascularisation. British Heart Foundation; UK National Health Service Management Executive; UK Stroke Association.

  10. Time to Treatment With Endovascular Thrombectomy and Outcomes From Ischemic Stroke: A Meta-analysis.

    PubMed

    Saver, Jeffrey L; Goyal, Mayank; van der Lugt, Aad; Menon, Bijoy K; Majoie, Charles B L M; Dippel, Diederik W; Campbell, Bruce C; Nogueira, Raul G; Demchuk, Andrew M; Tomasello, Alejandro; Cardona, Pere; Devlin, Thomas G; Frei, Donald F; du Mesnil de Rochemont, Richard; Berkhemer, Olvert A; Jovin, Tudor G; Siddiqui, Adnan H; van Zwam, Wim H; Davis, Stephen M; Castaño, Carlos; Sapkota, Biggya L; Fransen, Puck S; Molina, Carlos; van Oostenbrugge, Robert J; Chamorro, Ángel; Lingsma, Hester; Silver, Frank L; Donnan, Geoffrey A; Shuaib, Ashfaq; Brown, Scott; Stouch, Bruce; Mitchell, Peter J; Davalos, Antoni; Roos, Yvo B W E M; Hill, Michael D

    2016-09-27

    Endovascular thrombectomy with second-generation devices is beneficial for patients with ischemic stroke due to intracranial large-vessel occlusions. Delineation of the association of treatment time with outcomes would help to guide implementation. To characterize the period in which endovascular thrombectomy is associated with benefit, and the extent to which treatment delay is related to functional outcomes, mortality, and symptomatic intracranial hemorrhage. Demographic, clinical, and brain imaging data as well as functional and radiologic outcomes were pooled from randomized phase 3 trials involving stent retrievers or other second-generation devices in a peer-reviewed publication (by July 1, 2016). The identified 5 trials enrolled patients at 89 international sites. Endovascular thrombectomy plus medical therapy vs medical therapy alone; time to treatment. The primary outcome was degree of disability (mRS range, 0-6; lower scores indicating less disability) at 3 months, analyzed with the common odds ratio (cOR) to detect ordinal shift in the distribution of disability over the range of the mRS; secondary outcomes included functional independence at 3 months, mortality by 3 months, and symptomatic hemorrhagic transformation. Among all 1287 patients (endovascular thrombectomy + medical therapy [n = 634]; medical therapy alone [n = 653]) enrolled in the 5 trials (mean age, 66.5 years [SD, 13.1]; women, 47.0%), time from symptom onset to randomization was 196 minutes (IQR, 142 to 267). Among the endovascular group, symptom onset to arterial puncture was 238 minutes (IQR, 180 to 302) and symptom onset to reperfusion was 286 minutes (IQR, 215 to 363). At 90 days, the mean mRS score was 2.9 (95% CI, 2.7 to 3.1) in the endovascular group and 3.6 (95% CI, 3.5 to 3.8) in the medical therapy group. The odds of better disability outcomes at 90 days (mRS scale distribution) with the endovascular group declined with longer time from symptom onset to arterial puncture: cOR at 3 hours, 2.79 (95% CI, 1.96 to 3.98), absolute risk difference (ARD) for lower disability scores, 39.2%; cOR at 6 hours, 1.98 (95% CI, 1.30 to 3.00), ARD, 30.2%; cOR at 8 hours,1.57 (95% CI, 0.86 to 2.88), ARD, 15.7%; retaining statistical significance through 7 hours and 18 minutes. Among 390 patients who achieved substantial reperfusion with endovascular thrombectomy, each 1-hour delay to reperfusion was associated with a less favorable degree of disability (cOR, 0.84 [95% CI, 0.76 to 0.93]; ARD, -6.7%) and less functional independence (OR, 0.81 [95% CI, 0.71 to 0.92], ARD, -5.2% [95% CI, -8.3% to -2.1%]), but no change in mortality (OR, 1.12 [95% CI, 0.93 to 1.34]; ARD, 1.5% [95% CI, -0.9% to 4.2%]). In this individual patient data meta-analysis of patients with large-vessel ischemic stroke, earlier treatment with endovascular thrombectomy + medical therapy compared with medical therapy alone was associated with lower degrees of disability at 3 months. Benefit became nonsignificant after 7.3 hours.

  11. Parameter optimization of flux-aided backing-submerged arc welding by using Taguchi method

    NASA Astrophysics Data System (ADS)

    Pu, Juan; Yu, Shengfu; Li, Yuanyuan

    2017-07-01

    Flux-aided backing-submerged arc welding has been conducted on D36 steel with thickness of 20 mm. The effects of processing parameters such as welding current, voltage, welding speed and groove angle on welding quality were investigated by Taguchi method. The optimal welding parameters were predicted and the individual importance of each parameter on welding quality was evaluated by examining the signal-to-noise ratio and analysis of variance (ANOVA) results. The importance order of the welding parameters for the welding quality of weld bead was: welding current > welding speed > groove angle > welding voltage. The welding quality of weld bead increased gradually with increasing welding current and welding speed and decreasing groove angle. The optimum values of the welding current, welding speed, groove angle and welding voltage were found to be 1050 A, 27 cm/min, 40∘ and 34 V, respectively.

  12. Endovascular management of inferior vena cava filter thrombotic occlusion.

    PubMed

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  13. Predictors for Symptomatic Intracranial Hemorrhage After Endovascular Treatment of Acute Ischemic Stroke.

    PubMed

    Hao, Yonggang; Yang, Dong; Wang, Huaiming; Zi, Wenjie; Zhang, Meng; Geng, Yu; Zhou, Zhiming; Wang, Wei; Xu, Haowen; Tian, Xiguang; Lv, Penghua; Liu, Yuxiu; Xiong, Yunyun; Liu, Xinfeng; Xu, Gelin

    2017-05-01

    Symptomatic intracranial hemorrhage (SICH) pose a major safety concern for endovascular treatment of acute ischemic stroke. This study aimed to evaluate the risk and related factors of SICH after endovascular treatment in a real-world practice. Patients with stroke treated with stent-like retrievers for recanalizing a blocked artery in anterior circulation were enrolled from 21 stroke centers in China. Intracranial hemorrhage was classified as symptomatic and asymptomatic ones according to Heidelberg Bleeding Classification. Logistic regression was used to identify predictors for SICH. Of the 632 enrolled patients, 101 (16.0%) were diagnosed with SICH within 72 hours after endovascular treatment. Ninety-day mortality was higher in patients with SICH than in patients without SICH (65.3% versus 18.8%; P <0.001). On multivariate analysis, baseline neutrophil ratio >0.83 (odds ratio [OR], 2.07; 95% confidence interval [CI], 1.24-3.46), pretreatment Alberta Stroke Program Early Computed Tomography Score of <6 (OR, 2.27; 95% CI, 1.24-4.14), stroke of cardioembolism type (OR, 1.91; 95% CI, 1.13-3.25), poor collateral circulation (OR, 1.97; 95% CI, 1.16-3.36), delay from symptoms onset to groin puncture >270 minutes (OR, 1.70; 95% CI, 1.03-2.80), >3 passes with retriever (OR, 2.55; 95% CI, 1.40-4.65) were associated with SICH after endovascular treatment. Incidence of SICH after thrombectomy is higher in Asian patients with acute ischemic stroke. Cardioembolic stroke, poor collateral circulation, delayed endovascular treatment, multiple passes with stent retriever device, lower pretreatment Alberta Stroke Program Early Computed Tomography Score, higher baseline neutrophil ratio may increase the risk of SICH. © 2017 American Heart Association, Inc.

  14. Patient outcomes with endovascular embolectomy therapy for acute ischemic stroke: a study of the national inpatient sample: 2006 to 2008.

    PubMed

    Brinjikji, Waleed; Rabinstein, Alejandro A; Kallmes, David F; Cloft, Harry J

    2011-06-01

    Maturing techniques have spurred widespread implementation of endovascular embolectomy therapy for ischemic stroke. We evaluated a large administrative database to determine outcomes in patients treated with endovascular embolectomy in the general population. Using the National Inpatient Sample, we evaluated outcomes of patients treated for acute ischemic stroke in the United States from 2006 to 2008. Patients who had an ischemic stroke and underwent endovascular clot retrieval were identified. Morbidity, defined as "discharge to long-term facility," and mortality were evaluated as a function of patient age and of concomitant thrombolytic agent administration. For 2006 to 2008, a total of 3864 patients received endovascular clot retrieval with 266 (6.9%) patients in 2006, 800 (20.7) patients in 2007, and 2798 (72.4%) patients in 2008. The discharge to a long-term facility rate was 51.3% (1983 of 3864). The in-hospital mortality rate was 24.3% (940 of 3864). For patients <65 years old, the rate of in-hospital death was 17.1% (283 of 1658) as compared with a rate of 29.7% (656 of 2206) for patients ≥65 years old (P<0.0001). The rate of discharge to a long-term facility was 47.6% (789 of 1658) for patients <65 years old and 54.1% (1193 of 2206) for patients ≥65 years old (P<0.0001). The rate of intracranial hemorrhage was 15.5% without concomitant thrombolysis and 20.0% with concomitant thrombolysis (P=0.0009). Rates of morbidity and mortality remain high for patients with acute stroke, even in the setting of endovascular embolectomy. Advanced age portends a worse outcome and patients treated with concomitant use of thrombolytic agent had higher rates of intracranial hemorrhage than those without such therapy.

  15. Alberta Stroke Program Early CT Score-Time Score Predicts Outcome after Endovascular Therapy in Patients with Acute Ischemic Stroke: A Retrospective Single-Center Study.

    PubMed

    Todo, Kenichi; Sakai, Nobuyuki; Kono, Tomoyuki; Hoshi, Taku; Imamura, Hirotoshi; Adachi, Hidemitsu; Yamagami, Hiroshi; Kohara, Nobuo

    2018-04-01

    Clinical outcomes after successful endovascular therapy in patients with acute ischemic stroke are associated with several factors including onset-to-reperfusion time (ORT), the National Institute of Health Stroke Scale (NIHSS) score, and the Alberta Stroke Program Early CT Score (ASPECTS). The NIHSS-time score, calculated as follows: [NIHSS score] × [onset-to-treatment time (h)] or [NIHSS score] × [ORT (h)], has been reported to predict clinical outcomes after intravenous recombinant tissue plasminogen activator therapy and endovascular therapy for acute stroke. The objective of the current study was to assess whether the combination of the ASPECTS and the ORT can predict the outcomes after endovascular therapy. The charts of 117 consecutive ischemic stroke patients with successful reperfusion after endovascular therapy were retrospectively reviewed. We analyzed the association of ORT, ASPECTS, and ASPECTS-time score with clinical outcome. ASPECTS-time score was calculated as follows: [11 - ASPECTS] × [ORT (h)]. Rates of good outcome for patients with ASPECTS-time scores of tertile values, scores 5.67 or less, scores greater than 5.67 to 10.40 or less, and scores greater than 10.40, were 66.7%, 56.4%, and 33.3%, respectively (P < .05). Ordinal logistic regression analysis showed that the ASPECTS-time score (per category increase) was an independent predictor for better outcome (common odds ratio: .374; 95% confidence interval: .150-0.930; P < .05). A lower ASPECTS-time score may predict better clinical outcomes after endovascular treatment. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  16. Evolution of practice during the Interventional Management of Stroke III Trial and implications for ongoing trials.

    PubMed

    Broderick, Joseph P; Palesch, Yuko Y; Demchuk, Andrew M; Yeatts, Sharon D; Khatri, Pooja; Hill, Michael D; Jauch, Edward C; Jovin, Tudor G; Yan, Bernard; von Kummer, Rüdiger; Molina, Carlos A; Goyal, Mayank; Mazighi, Mikael; Schonewille, Wouter J; Engelter, Stefan T; Anderson, Craig; Spilker, Judith; Carrozzella, Janice; Janis, L Scott; Foster, Lydia D; Tomsick, Thomas A

    2014-12-01

    We explored changes in the patient population and practice of endovascular therapy during the course of the Interventional Management of Stroke (IMS) III Trial. Changes in baseline characteristics, use of baseline CT angiography, treatment times and specifics, and outcomes were compared between the first 4 protocols and the fifth and final protocol. Compared with subjects treated in the first 4 protocol versions (n=610), subjects treated in fifth and final protocol (n=46) were older (75 versus 68 years, P<0.0002) and less likely to have a pretreatment Rankin of 0 (76% versus 89%, P=0.01), were more likely to have a pretreatment CT angiography (65% versus 45%, P=0.009), had quicker median times in the endovascular arm from onset to start of intra-arterial therapy (209 versus 250 minutes, P=0.002) and to reperfusion (269 versus 344 minutes, P<0.0001), had a higher mean dose of total tissue-type plasminogen activator in the endovascular arm (74.0 versus 63.7 mg, P<0.0001), and were less likely to receive intra-arterial tissue-type plasminogen activator as part of the endovascular procedure (16% versus 44%, P=0.015). There were no significant differences in functional and safety outcomes between subjects treated in the 2 treatments arms in either the first 4 protocols or fifth protocol although the small sample size in the fifth protocol provided limited power. Endovascular technology and diagnostic approaches to acute stroke patients changed substantially during the IMS III Trial. Efforts to decrease the time to delivery of endovascular therapy were successful. © 2014 American Heart Association, Inc.

  17. Diffusion-Weighted Imaging-Detected Ischemic Lesions following Endovascular Treatment of Cerebral Aneurysms: A Systematic Review and Meta-Analysis.

    PubMed

    Bond, K M; Brinjikji, W; Murad, M H; Kallmes, D F; Cloft, H J; Lanzino, G

    2017-02-01

    Endovascular treatment of intracranial aneurysms is associated with the risk of thromboembolic ischemic complications. Many of these events are asymptomatic and identified only on diffusion-weighted imaging. We performed a systematic review and meta-analysis to study the incidence of DWI positive for thromboembolic events following endovascular treatment of intracranial aneurysms. A comprehensive literature search identified studies published between 2000 and April 2016 that reported postprocedural DWI findings in patients undergoing endovascular treatment of intracranial aneurysms. The primary outcome was the incidence of DWI positive for thromboembolic events. We examined outcomes by treatment type, sex, and aneurysm characteristics. Meta-analyses were performed by using a random-effects model. Twenty-two studies with 2148 patients and 2268 aneurysms were included. The overall incidence of DWI positive for thromboembolic events following endovascular treatment was 49% (95% CI, 42%-56%). Treatment with flow diversion trended toward a higher rate of DWI positive for lesions than coiling alone (67%; 95% CI, 46%-85%; versus 45%; 95% CI, 33%-56%; P = .07). There was no difference between patients treated with coiling alone and those treated with balloon-assisted (44%; 95% CI, 29%-60%; P = .99) or stent-assisted (43%; 95% CI, 24%-63%; P = .89) coiling. Sex, aneurysm rupture status, location, and size were not associated with the rate of DWI positive for lesions. One in 2 patients may have infarcts on DWI following endovascular treatment of intracranial aneurysms. There is a trend toward a higher incidence of DWI-positive lesions following treatment with flow diversion compared with coiling. Patient demographics and aneurysm characteristics were not associated with DWI-positive thromboembolic events. © 2017 by American Journal of Neuroradiology.

  18. Endovascular Procedures in Treatment of Infrapopliteal Arterial Occlusive Disease: Single Center Experience With 69 Infrapopliteal Procedures.

    PubMed

    Janko, Pasternak J; Nebojsa, Budakov B; Andrej, Petres V

    2018-03-01

    Peripheral arterial occlusive disease (PAD) includes acute and chronic disorders of the blood supply as a result of obstruction of blood flow in the arteries of the limb. Treatment of PAD can be conservative, surgical and endovascular. Percutaneous transluminal angioplasty with or without stenting has become a recognized method, which is increasingly used in treatment of arterial occlusive disease. This study aimed to determine early results of endovascular treatment of critical limb ischemia (CLI) patients with infrapopliteal lesions. The study included 69 patients (46 men; mean age 65 years, range 38-84) with CLI (class 4 to 6 according to Rutherford). The primary study endpoints were absence of major amputation of the target limb at 6 months and occurance of local and systemic complications specifically related to use of endovascular treatment. Major amputation was avoided in 61 patients. Through 6 months, 6 patients underwent additional revascularization. One local complication (clinicaly significant dissection of popliteal artery) occurred, and it was resolved by stent implantation. There were no cases of systemic complications and death during the follow-up period. Rates of major amputation were 12.3% for diabetics versus 8.3% for non-diabetics. Our data showed that endovascular treatment of infrapopliteal disease is an effective and safe treatment in patients experiencing CLI, provides high limb preservation and low complication rates. Study outcomes support endovascular treatment as a primary option for patients experiencing CLI due to below the knee (BTK) occlusive disease. © 2018 The Author(s). This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  19. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Tian-Tian, E-mail: matthewwu1979@126.com; Li, Hu-Cheng, E-mail: hucheng-li-surgery@126.com; Zheng, Fang, E-mail: fang-zheng-surgery@126.com

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portalmore » stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.« less

  20. Fine-motor skills testing and prediction of endovascular performance.

    PubMed

    Bech, Bo; Lönn, Lars; Schroeder, Torben V; Ringsted, Charlotte

    2013-12-01

    Performing endovascular procedures requires good control of fine-motor digital movements and hand-eye coordination. Objective assessment of such skills is difficult. Trainees acquire control of catheter/wire movements at various paces. However, little is known to what extent talent plays for novice candidates at entry to practice. To study the association between performance in a novel aptitude test of fine-motor skills and performance in simulated procedures. The test was based on manual course-tracking using a proprietary hand-operated roller-bar device coupled to a personal computer with monitor view rotation. A total of 40 test repetitions were conducted separately with each hand. Test scores were correlated with simulator performance. Group A (n = 14), clinicians with various levels of endovascular experience, performed a simulated procedure of contralateral iliac artery stenting. Group B (n = 19), medical students, performed 10 repetitions of crossing a challenging aortic bifurcation in a simulator. The test score differed markedly between the individuals in both groups, in particular with the non-dominant hand. Group A: the test score with the non-dominant hand correlated significantly with simulator performance assessed with the global rating scale SAVE (R = -0.69, P = 0.007). There was no association observed from performances with the dominant hand. Group B: there was no significant association between the test score and endovascular skills acquisition neither with the dominant nor with the non-dominant hand. Clinicians with increasing levels of endovascular technical experience had developed good fine-motor control of the non-dominant hand, in particular, that was associated with good procedural performance in the simulator. The aptitude test did not predict endovascular skills acquisition among medical students, thus, cannot be suggested for selection of novice candidates. Procedural experience and practice probably supplant the influence of innate abilities (talent) over time.

  1. Safety of Endovascular Intervention for Stroke on Therapeutic Anticoagulation: Multicenter Cohort Study and Meta-Analysis.

    PubMed

    Kurowski, Donna; Jonczak, Karin; Shah, Qaisar; Yaghi, Shadi; Marshall, Randolph S; Ahmad, Haroon; McKinney, James; Torres, Jose; Ishida, Koto; Cucchiara, Brett

    2017-05-01

    Intravenous (IV) tissue plasminogen activator (tPA) is contraindicated in therapeutically anti-coagulated patients. Such patients may be considered for endovascular intervention. However, there are limited data on its safety. We performed a multicenter retrospective study of patients undergoing endovascular intervention for acute ischemic stroke while on therapeutic anticoagulation. We compared the observed rate of National Institute of Neurological Disorders and Stroke defined symptomatic intracerebral hemorrhage (sICH) with risk-adjusted historical control rates of sICH after IV tPA using weighted averages of the hemorrhage after thrombolysis (HAT) and Multicenter Stroke Survey (MSS) prediction scores. We also performed a metaanalysis of studies assessing risk of sICH with endovascular intervention in patients on anticoagulation. Of 94 cases, mean age was 73 years and median National Institutes of Health Stroke Scale was 19. Anticoagulation consisted of warfarin (n = 51), dabigatran (n = 6), rivaroxaban (n = 13), apixaban (n = 1), IV heparin (n = 19), low molecular weight heparin (n = 3), and combined warfarin and IV heparin (n = 3). sICH was seen in 7 patients (7%, 95% confidence interval 4-15), all on warfarin. Predicted sICH rates for the cohort based on HAT and MSS scoring were 12% and 7%, respectively. Meta-analysis of 6 studies showed no significant difference in sICH between patients undergoing endovascular intervention on anticoagulation and comparator groups. Endovascular intervention in subjects on therapeutic anticoagulation appears reasonably safe, with a sICH rate similar to patients not on anticoagulation receiving IV tPA. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  2. Underwater laser weld bowing distortion behavior and mechanism of thin 304 stainless steel plates

    NASA Astrophysics Data System (ADS)

    Huang, ZunYue; Luo, Zhen; Ao, Sansan; Cai, YangChuan

    2018-10-01

    Underwater laser weld bowing distortion behavior and mechanism of thin 304 stainless steel plates are studied in the paper. The influence of underwater laser welding parameters (such as laser power, welding speed, defocusing distance and gas flow rate) on weld bowing distortion was investigated through central composite rotatable design and an orthogonal test. A quadratic response model was established to evaluate the underwater laser weld bowing distortion by central composite rotatable design and the order of the impacts of the welding parameters on weld bowing distortion was studied by an orthogonal test. The weld bowing distortion after welding was determined by the digital image correlation technique. The weld bowing distortion of in-air laser welding and underwater laser welding were compared and it revealed that the shape of the in-air and underwater laser welded specimens are the same, but the weld bowing distortion amount of in-air welding is larger than that of underwater welding. Weld bowing distortion mechanism was studied by the digital image correlation technique, and it was demonstrated that weld bowing distortion is associated with the welding plate temperature gradient during laser welding. The wider weld width also resulted in larger weld bowing distortion.

  3. Endovascular Treatment of a Ruptured Internal Thoracic Artery Pseudoaneurysm Presenting as a Massive Hemothorax in a Patient with Type I Neurofibromatosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Soo Jin; Kim, Chang Won, E-mail: radkim@hanafos.com; Kim, Suk

    We report a case of acute hemothorax caused by a left internal thoracic artery pseudoaneurysm rupture in a patient with neurofibromatosis type I, which was successfully treated with endovascular coil embolization.

  4. REBOA at Role 2 Afloat: resuscitative endovascular balloon occlusion of the aorta as a bridge to damage control surgery in the military maritime setting.

    PubMed

    Rees, Paul; Waller, B; Buckley, A M; Doran, C; Bland, S; Scott, T; Matthews, J

    2018-05-01

    Role 2 Afloat provides a damage control resuscitation and surgery facility in support of maritime, littoral and aviation operations. Resuscitative endovascular balloon occlusion of the aorta (REBOA) offers a rapid, effective solution to exsanguinating haemorrhage from pelvic and non-compressible torso haemorrhage. It should be considered when the patient presents in a peri-arrest state, if surgery is likely to be delayed, or where the single operating table is occupied by another case. This paper will outline the data in support of endovascular haemorrhage control, describe the technique and explore how REBOA could be delivered using equipment currently available in the Royal Navy Role 2 Afloat equipment module. Also discussed are potential future directions in endovascular resuscitation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Endovascular Exclusion of Visceral Artery Aneurysms with Stent-Grafts: Technique and Long-Term Follow-up

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossi, Michele; Rebonato, Alberto, E-mail: albertorebonato@libero.it; Greco, Laura

    This paper describes four cases of visceral artery aneurysms (VAAs) successfully treated with endovascular stent-grafts and discusses the endovascular approach to VAAs and the long-term results. Four balloon expandable stent-grafts were used to treat three splenic artery aneurysms and one bleeding common hepatic artery pseudoaneurysm. The percutaneous access site and the materials were chosen on the basis of CT angiography findings. In all cases the aneurysms were successfully excluded. In one case a splenic infarction occurred, with nonrelevant clinical findings. At 16- to 24-month follow-up three patients had patent stents and complete exclusion and shrinkage of the aneurysms. One patientmore » died due to pancreatitis and sepsis, 16 days after successful stenting and exclusion of a bleeding pseudoaneurysm. We conclude that endovascular treatment using covered stent-grafts is a valid therapeutic option for VAAs. Multislice CT preoperative study helps in planning stent-graft positioning.« less

  6. Early-Dynamic Positron Emission Tomography (PET)/Computed Tomography and PET Angiography for Endoleak Detection After Endovascular Aneurysm Repair.

    PubMed

    Drescher, Robert; Gühne, Falk; Freesmeyer, Martin

    2017-06-01

    To propose a positron emission tomography (PET)/computed tomography (CT) protocol including early-dynamic and late-phase acquisitions to evaluate graft patency and aneurysm diameter, detect endoleaks, and rule out graft or vessel wall inflammation after endovascular aneurysm repair (EVAR) in one examination without intravenous contrast medium. Early-dynamic PET/CT of the endovascular prosthesis is performed for 180 seconds immediately after intravenous injection of F-18-fluorodeoxyglucose. Data are reconstructed in variable time frames (time periods after tracer injection) to visualize the arterial anatomy and are displayed as PET angiography or fused with CT images. Images are evaluated in view of vascular abnormalities, graft configuration, and tracer accumulation in the aneurysm sac. Whole-body PET/CT is performed 90 to 120 minutes after tracer injection. This protocol for early-dynamic PET/CT and PET angiography has the potential to evaluate vascular diseases, including the diagnosis of complications after endovascular procedures.

  7. Toward an endovascular internal carotid artery classification system.

    PubMed

    Shapiro, M; Becske, T; Riina, H A; Raz, E; Zumofen, D; Jafar, J J; Huang, P P; Nelson, P K

    2014-02-01

    Does the world need another ICA classification scheme? We believe so. The purpose of proposed angiography-driven classification is to optimize description of the carotid artery from the endovascular perspective. A review of existing, predominantly surgically-driven classifications is performed, and a new scheme, based on the study of NYU aneurysm angiographic and cross-sectional databases is proposed. Seven segments - cervical, petrous, cavernous, paraophthlamic, posterior communicating, choroidal, and terminus - are named. This nomenclature recognizes intrinsic uncertainty in precise angiographic and cross-sectional localization of aneurysms adjacent to the dural rings, regarding all lesions distal to the cavernous segment as potentially intradural. Rather than subdividing various transitional, ophthalmic, and hypophyseal aneurysm subtypes, as necessitated by their varied surgical approaches and risks, the proposed classification emphasizes their common endovascular treatment features, while recognizing that many complex, trans-segmental, and fusiform aneurysms not readily classifiable into presently available, saccular aneurysm-driven schemes, are being increasingly addressed by endovascular means. We believe this classification may find utility in standardizing nomenclature for outcome tracking, treatment trials and physician communication.

  8. Endovascular Therapy after Intravenous t-PA versus t-PA Alone for Stroke

    PubMed Central

    Broderick, Joseph P.; Palesch, Yuko Y.; Demchuk, Andrew M.; Yeatts, Sharon D.; Khatri, Pooja; Hill, Michael D.; Jauch, Edward C.; Jovin, Tudor G.; Yan, Bernard; Silver, Frank L.; von Kummer, Rüdiger; Molina, Carlos A.; Demaerschalk, Bart M.; Budzik, Ronald; Clark, Wayne M.; Zaidat, Osama O.; Malisch, Tim W.; Goyal, Mayank; Schonewille, Wouter J.; Mazighi, Mikael; Engelter, Stefan T.; Anderson, Craig; Spilker, Judith; Carrozzella, Janice; Ryckborst, Karla J.; Janis, L. Scott; Martin, Renée H.; Foster, Lydia D.; Tomsick, Thomas A.

    2013-01-01

    BACKGROUND Endovascular therapy is increasingly used after the administration of intravenous tissue plasminogen activator (t-PA) for patients with moderate-to-severe acute ischemic stroke, but whether a combined approach is more effective than intravenous t-PA alone is uncertain. METHODS We randomly assigned eligible patients who had received intravenous t-PA within 3 hours after symptom onset to receive additional endovascular therapy or intravenous t-PA alone, in a 2:1 ratio. The primary outcome measure was a modified Rankin scale score of 2 or less (indicating functional independence) at 90 days (scores range from 0 to 6, with higher scores indicating greater disability). RESULTS The study was stopped early because of futility after 656 participants had undergone randomization (434 patients to endovascular therapy and 222 to intravenous t-PA alone). The proportion of participants with a modified Rankin score of 2 or less at 90 days did not differ significantly according to treatment (40.8% with endovascular therapy and 38.7% with intravenous t-PA; absolute adjusted difference, 1.5 percentage points; 95% confidence interval [CI], −6.1 to 9.1, with adjustment for the National Institutes of Health Stroke Scale [NIHSS] score [8–19, indicating moderately severe stroke, or ≥20, indicating severe stroke]), nor were there significant differences for the predefined subgroups of patients with an NIHSS score of 20 or higher (6.8 percentage points; 95% CI, −4.4 to 18.1) and those with a score of 19 or lower (−1.0 percentage point; 95% CI, −10.8 to 8.8). Findings in the endovascular-therapy and intravenous t-PA groups were similar for mortality at 90 days (19.1% and 21.6%, respectively; P = 0.52) and the proportion of patients with symptomatic intracerebral hemorrhage within 30 hours after initiation of t-PA (6.2% and 5.9%, respectively; P = 0.83). CONCLUSIONS The trial showed similar safety outcomes and no significant difference in functional independence with endovascular therapy after intravenous t-PA, as compared with intravenous t-PA alone. (Funded by the National Institutes of Health and others; ClinicalTrials.gov number, NCT00359424.) PMID:23390923

  9. Parent artery occlusion for ruptured “true” posterior communicating artery aneurysm

    PubMed Central

    Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-01-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgical clipping over endovascular coil embolization. Endovascular treatment may be a good alternative to surgical trapping for true PCoA blister aneurysm. PMID:25953771

  10. Endovascular aortic aneurysm repair with chimney and snorkel grafts: indications, techniques and results.

    PubMed

    Patel, Rakesh P; Katsargyris, Athanasios; Verhoeven, Eric L G; Adam, Donald J; Hardman, John A

    2013-12-01

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  11. Endovascular Treatment of Pulsatile Tinnitus by Sigmoid Sinus Aneurysm: Technical Note and Review of the Literature.

    PubMed

    Cuellar, Hugo; Maiti, Tanmoy; Patra, Devi Prasad; Savardekar, Amey; Sun, Hai; Nanda, Anil

    2018-05-01

    Pulse-synchronous tinnitus is rare, and it almost always points toward a vascular pathology. We encountered a 56-year-old patient presenting with a 3-month history of right-side tinnitus who was found to have a sigmoid sinus aneurysm after initial imaging. The patient was managed successfully with dual endovascular access and stent placement across the aneurysm, with a subsequent complete symptomatic relief. Description of the endovascular management of sigmoid sinus aneurysm is not infrequent in the literature. This report provides a brief review of the available literature specifically addressing the management strategies. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Internal Carotid Artery Pseudoaneurysm after Tonsillectomy Treated by Endovascular Approach

    PubMed Central

    Raffin, C.N.; Montovani, J.C.; Neto, J.M.P.; Campos, C.M.S.; Piske, R.L.

    2002-01-01

    Summary Surgery on the head and neck region may be complicated by vascular trauma, caused by direct injury on the vascular wall. Lesions of the arteries are more dangerous than the venous one. The traumatic lesion may cause laceration of the artery wall, spasm, dissection, arteriovenous fistula, occlusion or pseudoaneurysm. We present a case of a child with a giant ICA pseudoaneurysm after tonsillectomy, manifested by pulsing mass and respiratory distress, which was treated by endovascular approach, occluding the lesion and the proximal artery with Histoacryl. We reinforce that the endovascular approach is the better way to treat most of the traumatic vascular lesions. PMID:20594516

  13. Endovascular treatment of isolated systemic arterial supply to normal lung with coil and glue embolisation

    PubMed Central

    Anil, G; Taneja, M; Tan, A-G-S

    2012-01-01

    Surgery is the standard treatment for the extremely rare pathology of isolated anomalous systemic arterial supply to normal lung (ISSNL). We describe our experience with this anomaly in a 29-year-old male presenting with recurrent haemoptysis that was successfully treated with a combination of metallic coils and cyanoacrylate glue. In addition to contributing to the extremely limited data on endovascular therapeutic options in ISSNL, we also intend to raise the awareness among endovascular therapists of the need to be cautious ofand preserve the radiculomedullary/pial branches arising from an anomalous artery before embolising it. PMID:22457413

  14. The endovascular treatment of a spinal perimedullary arteriovenous fistula with coils: a case report.

    PubMed

    Pasqualetto, L; Papa, R; Isalberti, M; Nuzzi, N P; Branca, V

    2011-03-01

    We report a case of direct spinal intradural ventral arteriovenous fistula of the thoraco-lumbar region. Angiography demonstrated a single feeder from the anterior spinal artery that drained directly into a markedly dilated vein without an intervening nidus. The endovascular treatment was performed by a transarterial approach and the occlusion of the fistula, after a failed treatment by a detachable balloon, was obtained by coils released in the initial fistulous site inside a venous dilatation with complete clinical cure. This case indicates that endovascular treatment is possible using coils as a valid and safe alternative to a balloon, glue or surgical approach.

  15. Endovascular Repair of Abdominal Aortic Aneurysms

    PubMed Central

    Sternbergh, W. Charles; Yoselevitz, Moises; Money, Samuel R.

    1999-01-01

    Endovascular treatment of abdominal aortic aneurysms (AAAs) is an exciting new minimally invasive treatment option for patients with this disease. Ochsner Clinic has been the only institution in the Gulf South participating in FDA clinical trials of these investigational devices. Early results with endovascular AAA repair demonstrate a trend towards lower mortality and morbidity when compared with traditional open surgery. Length of stay has been reduced by two-thirds with a marked reduction in postoperative pain and at-home convalescence. If the long-term data on efficacy and durability of these devices are good, most AAAs in the future will be treated with this minimally invasive technique. PMID:21845135

  16. Endovascular Treatment of Totally Occluded Superior Mesenteric Artery by Retrograde Crossing via the Villemin Arcade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara

    2013-06-15

    Chronic mesenteric ischemia (CMI) is a rare disorder that is commonly caused by progressive atherosclerotic stenosis or occlusion of one or more mesenteric arteries. Endovascular treatment for symptomatic CMI represents a viable option, especially in high-operative risk patients. We report a case of acute symptomatic CMI with chronic totally occlusion of the superior mesenteric artery (SMA) associated with significant stenosis of celiac trunk (CT) and inferior mesenteric artery (IMA) that underwent endovascular treatment of all the three mesenteric arteries: stenting of CT and IMA stenosis, and recanalization of the SMA occlusion by retrograde crossing via the Villemin arcade.

  17. Relevance of Occlusion Test in Endovascular Coiling of Posterior Cerebral Artery (P2 Segment) Aneurysms

    PubMed Central

    Jayakumar, P. N.; Desai, S.; Srikanth, S. G.; Ravishankar, S.; Kovoor, J. M. E.

    2004-01-01

    Summary P2 segment aneurysms are located on the posterior cerebral artery (PCA) between the junction of the posterior communicating artery with the PCA and the quadrigeminal cisternal part of the PCA. We reviewed our experience with endovascular coiling in such aneurysms. Clinical and pre-procedural data from four patients, referred for endovascular treatment of P2 segment aneurysms, were retrospectively studied for factors influencing post-interventional neurological deficits caused by ischemia of the PCA distal territory. Balloon occlusion was done in three patients and patient tolerance was assessed using clinical and anatomic criteria. Embryologic and anatomic features of the PCA were reviewed. Balloon occlusion test and endovascular coiling of aneurysms was possible in three patients. Control angiogram after embolization showed elimination of aneurysms from the circulation and the distal PCA filled through leptomeningeal anastomoses. One patient deteriorated due to aneurysmal rupture soon after the balloon occlusion test and coiling could not be done. In the other three patients post-intervention CT and MRI images showed PCA territory infarcts in spite of demonstration of good collateral circulation distal to the occluded PCA. In conclusion, P2 aneurysms can be effectively treated by endovascular coiling without a balloon occlusion test. While the balloon occlusion test does not contribute to clinical decision-making it may be associated with potential morbidity and mortality. PMID:20587236

  18. Comparison of the Incidence of Complications and Secondary Surgical Interventions Necessary in Patients with Chronic Lower Limb Ischemia Treated by Both Open and Endovascular Surgeries

    PubMed Central

    Janczak, Dariusz; Malinowski, Maciej; Bąkowski, Wojciech; Krakowska, Katarzyna; Marschollek, Karol; Marschollek, Paweł

    2017-01-01

    Background: Peripheral arterial disease (PAD) affects 3%–10% of the population before the age of 70 years and 15%–20% after that age. The aim of the study was to compare the incidence of complications and secondary interventions in patients who underwent each type of treatment. Methods: We analyzed 734 medical records of the Department of Surgery at the 4th Military Teaching Hospital in Wroclaw, In total, 394 were operated on with open surgery; an endarterectomy (59.39%), a vascular prosthesis implantation (31.01%), or both of these techniques (6.6%), and 340 patients had angioplasty with (50.59%) or without stenting (49.41%). Results: There were no statistically significant differences in the incidence of corresponding complications. The exception was the infection of the wound; significantly fewer were reported in the case of endovascular procedures (p = 0.0087). There were 12 occasions (3.53%) during endovascular surgeries when intraoperative conversion or re-operation using the open method occurred. In the case of open surgery, the mean hospital stay was 7.77 days (median: 8, mode: 8), while for endovascular management it was equal to 4.68 days (median: 4, mode: 3), p <0.0001. Conclusion: The endovascular method results in a similar re-operation rate and number of complications as open surgery. PMID:28496017

  19. Effect of endovascular treatment on nitric oxide and renal function in Takayasu's arteritis with renovascular hypertension.

    PubMed

    Parildar, Zuhal; Gulter, Ceyda; Parildar, Mustafa; Oran, Ismail; Erdener, Dilek; Memis, Ahmet

    2002-01-01

    Renal involvement in Takayasu's arteritis (TA) effects the disease outcome and endovascular treatment is an effective treatment of choice. We investigated nitric oxide (NO) levels and the effect of endovascular treatment in renovascular hypertensive TA patients. In five hypertensive patients with renal artery stenosis due to TA, serum creatinine, nitrite, nitrate; urinary microalbumin, nitrite, nitrate measurements and blood pressures were recorded at entry and after 24 h and 6 weeks of endovascular treatment. Serum NO levels were higher in patients than controls (p = 0.008). Serum and urine NO levels increased 24 h after the treatment and decreased after 6 weeks (p = 0.015; p = 0.01, respectively). After the treatment blood pressures decreased. Urinary microalbumin excretions increased after the intervention (p = 0.02) and returned to normal in patients 1 and 4, and decreased in the others. There were no significant differences in estimated glomerular filtration rate (EGFR), serum creatinine, urinary sodium and potassium levels. Increased NO secretion in these patients may contribute to improve the prognosis of renal function through its vasodilator and antiproliferative activities possibly by counterbalancing the excessive vasoconstrictor actions. Endovascular treatment causes a dilatation-induced shear stress that may be responsible for the increased NO release, which in turn leads to the rapid hypotensive response. Copyright 2002 S. Karger AG, Basel

  20. Effect of general anaesthesia on functional outcome in patients with anterior circulation ischaemic stroke having endovascular thrombectomy versus standard care: a meta-analysis of individual patient data.

    PubMed

    Campbell, Bruce C V; van Zwam, Wim H; Goyal, Mayank; Menon, Bijoy K; Dippel, Diederik W J; Demchuk, Andrew M; Bracard, Serge; White, Philip; Dávalos, Antoni; Majoie, Charles B L M; van der Lugt, Aad; Ford, Gary A; de la Ossa, Natalia Pérez; Kelly, Michael; Bourcier, Romain; Donnan, Geoffrey A; Roos, Yvo B W E M; Bang, Oh Young; Nogueira, Raul G; Devlin, Thomas G; van den Berg, Lucie A; Clarençon, Frédéric; Burns, Paul; Carpenter, Jeffrey; Berkhemer, Olvert A; Yavagal, Dileep R; Pereira, Vitor Mendes; Ducrocq, Xavier; Dixit, Anand; Quesada, Helena; Epstein, Jonathan; Davis, Stephen M; Jansen, Olav; Rubiera, Marta; Urra, Xabier; Micard, Emilien; Lingsma, Hester F; Naggara, Olivier; Brown, Scott; Guillemin, Francis; Muir, Keith W; van Oostenbrugge, Robert J; Saver, Jeffrey L; Jovin, Tudor G; Hill, Michael D; Mitchell, Peter J

    2018-01-01

    General anaesthesia (GA) during endovascular thrombectomy has been associated with worse patient outcomes in observational studies compared with patients treated without GA. We assessed functional outcome in ischaemic stroke patients with large vessel anterior circulation occlusion undergoing endovascular thrombectomy under GA, versus thrombectomy not under GA (with or without sedation) versus standard care (ie, no thrombectomy), stratified by the use of GA versus standard care. For this meta-analysis, patient-level data were pooled from all patients included in randomised trials in PuMed published between Jan 1, 2010, and May 31, 2017, that compared endovascular thrombectomy predominantly done with stent retrievers with standard care in anterior circulation ischaemic stroke patients (HERMES Collaboration). The primary outcome was functional outcome assessed by ordinal analysis of the modified Rankin scale (mRS) at 90 days in the GA and non-GA subgroups of patients treated with endovascular therapy versus those patients treated with standard care, adjusted for baseline prognostic variables. To account for between-trial variance we used mixed-effects modelling with a random effect for trials incorporated in all models. Bias was assessed using the Cochrane method. The meta-analysis was prospectively designed, but not registered. Seven trials were identified by our search; of 1764 patients included in these trials, 871 were allocated to endovascular thrombectomy and 893 were assigned standard care. After exclusion of 74 patients (72 did not undergo the procedure and two had missing data on anaesthetic strategy), 236 (30%) of 797 patients who had endovascular procedures were treated under GA. At baseline, patients receiving GA were younger and had a shorter delay between stroke onset and randomisation but they had similar pre-treatment clinical severity compared with patients who did not have GA. Endovascular thrombectomy improved functional outcome at 3 months both in patients who had GA (adjusted common odds ratio (cOR) 1·52, 95% CI 1·09-2·11, p=0·014) and in those who did not have GA (adjusted cOR 2·33, 95% CI 1·75-3·10, p<0·0001) versus standard care. However, outcomes were significantly better for patients who did not receive GA versus those who received GA (covariate-adjusted cOR 1·53, 95% CI 1·14-2·04, p=0·0044). The risk of bias and variability between studies was assessed to be low. Worse outcomes after endovascular thrombectomy were associated with GA, after adjustment for baseline prognostic variables. These data support avoidance of GA whenever possible. The procedure did, however, remain effective versus standard care in patients treated under GA, indicating that treatment should not be withheld in those who require anaesthesia for medical reasons. Medtronic. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Endovascular treatment of arterio-ureteral fistulae with covered stents: Case series and review of the literature.

    PubMed

    Patel, Dhruv; Kumar, Abhishek; Ranganath, Praveen; Contractor, Sohail

    2014-01-01

    Arterio-ureteral fistulae are abnormal connections between an artery and the ureter and carry a high mortality. We present two cases of arterio-ureteral fistulae that presented with life-threatening hematuria. Both patients were treated with endovascular covered stent placement.

  2. Endovascular treatment of arterio-ureteral fistulae with covered stents: Case series and review of the literature

    PubMed Central

    Patel, Dhruv; Ranganath, Praveen; Contractor, Sohail

    2014-01-01

    Arterio-ureteral fistulae are abnormal connections between an artery and the ureter and carry a high mortality. We present two cases of arterio-ureteral fistulae that presented with life-threatening hematuria. Both patients were treated with endovascular covered stent placement. PMID:27489652

  3. Endovascular Aneurysm Repair Using a Reverse Chimney Technique in a Patient With Marfan Syndrome and Contained Ruptured Chronic Type B Dissection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ketelsen, Dominik; Kalender, Guenay; Heuschmid, Martin

    2011-10-15

    We report endovascular thoracic and abdominal aneurysm repair (EVAR) with reverse chimney technique in a patient with contained ruptured type B dissection. EVAR seems feasible as a bailout option in Marfan patients with acute life-threatening disease.

  4. Long-term risk of carotid restenosis in patients randomly assigned to endovascular treatment or endarterectomy in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial

    PubMed Central

    Bonati, Leo H; Ederle, Jörg; McCabe, Dominick JH; Dobson, Joanna; Featherstone, Roland L; Gaines, Peter A; Beard, Jonathan D; Venables, Graham S; Markus, Hugh S; Clifton, Andrew; Sandercock, Peter; Brown, Martin M

    2009-01-01

    Summary Background In the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS), early recurrent carotid stenosis was more common in patients assigned to endovascular treatment than it was in patients assigned to endarterectomy (CEA), raising concerns about the long-term effectiveness of endovascular treatment. We aimed to investigate the long-term risks of restenosis in patients included in CAVATAS. Methods 413 patients who were randomly assigned in CAVATAS and completed treatment for carotid stenosis (200 patients had endovascular treatment and 213 patients had endarterectomy) had prospective clinical follow-up at a median of 5 years and carotid duplex ultrasound at a median of 4 years. We investigated the cumulative long-term incidence of carotid restenosis after endovascular treatment and endarterectomy, the effect of the use of stents on restenosis after endovascular treatment, risk factors for the development of restenosis, and the effect of carotid restenosis on the risk of recurrent cerebrovascular events. Analysis was by intention to treat. This study is registered, number ISRCTN01425573. Findings Severe carotid restenosis (≥70%) or occlusion occurred significantly more often in patients in the endovascular arm than in patients in the endarterectomy arm (adjusted hazard ratio [HR] 3·17, 95% CI 1·89–5·32; p<0·0001). The estimated 5-year incidence of restenosis was 30·7% in the endovascular arm and 10·5% in the endarterectomy arm. Patients in the endovascular arm who were treated with a stent (n=50) had a significantly lower risk of developing restenosis of 70% or greater compared with those treated with balloon angioplasty alone (n=145; HR 0·43, 0·19–0·97; p=0·04). Current smoking or a history of smoking was a predictor of restenosis of 70% or more (2·32, 1·19–4·54; p=0·01) and the early finding of moderate stenosis (50–69%) up to 60 days after treatment was associated with the risk of progression to restenosis of 70% or more (3·76, 1·88–7·52; p=0·0002). The composite endpoint of ipsilateral non-perioperative stroke or transient ischaemic attack occurred more often in patients in whom restenosis of 70% or more was diagnosed in the first year after treatment compared with patients without restenosis of 70% or more (5-year incidence 23% vs 11%; HR 2·18, 1·04–4·54; p=0·04), but the increase in ipsilateral stroke alone was not significant (10% vs 5%; 1·67, 0·54–5·11). Interpretation Restenosis is about three times more common after endovascular treatment than after endarterectomy and is associated with recurrent ipsilateral cerebrovascular symptoms; however, the risk of recurrent ipsilateral stroke is low. Further data are required from on-going trials of stenting versus endarterectomy to ascertain whether long-term ultrasound follow-up is necessary after carotid revascularisation. Funding British Heart Foundation; UK National Health Service Management Executive; UK Stroke Association. PMID:19717347

  5. Investigation on mechanical properties of welded material under different types of welding filler (shielded metal arc welding)

    NASA Astrophysics Data System (ADS)

    Tahir, Abdullah Mohd; Lair, Noor Ajian Mohd; Wei, Foo Jun

    2018-05-01

    The Shielded Metal Arc Welding (SMAW) is (or the Stick welding) defined as a welding process, which melts and joins metals with an arc between a welding filler (electrode rod) and the workpieces. The main objective was to study the mechanical properties of welded metal under different types of welding fillers and current for SMAW. This project utilized the Design of Experiment (DOE) by adopting the Full Factorial Design. The independent variables were the types of welding filler and welding current, whereas the other welding parameters were fixed at the optimum value. The levels for types of welding filler were by the models of welding filler (E6013, E7016 and E7018) used and the levels for welding current were 80A and 90A. The responses were the mechanical properties of welded material, which include tensile strength and hardness. The experiment was analyzed using the two way ANOVA. The results prove that there are significant effects of welding filler types and current levels on the tensile strength and hardness of the welded metal. At the same time, the ANOVA results and interaction plot indicate that there are significant interactions between the welding filler types and the welding current on both the hardness and tensile strength of the welded metals, which has never been reported before. This project found that when the amount of heat input with increase, the mechanical properties such as tensile strength and hardness decrease. The optimum tensile strength for welded metal is produced by the welding filler E7016 and the optimum of hardness of welded metal is produced by the welding filler E7018 at welding current of 80A.

  6. Study of Gravity Effects on Titanium Laser Welding in the Vertical Position

    PubMed Central

    Yuan, Zhang; Pu, Haitao; Li, Haigang; Cheng, Hao; Du, Dong; Shan, Jiguo

    2017-01-01

    To obtain satisfactory welds in positional laser beam welding, it is necessary to know how process parameters will influence the quality of welds in different welding positions. In this study, the titanium alloy Ti6Al4V sheets were laser welded in two vertical welding positions (vertical up and vertical down), and the appearance, porosity, strength, and ductility of the laser joints were evaluated. Results show that undercuts of the vertical up welds were greater than that of vertical down welds, while the porosity contents were much higher in vertical down welds than that in vertical up welds. When welding with a higher heat input, the vertical up welding position resulted in poor weld profiles (undercuts and burn-through holes), whereas the vertical down welding position led to excessive porosity contents in welds. Both severe undercut and excessive porosity were detrimental to the tensile properties of the welds. Weld appearance was improved and porosity contents were reduced by using a lower heat input, achieving better weld quality. Therefore, it is suggested that process parameter settings with relatively high laser powers and welding speeds, which can result in lower heat inputs, are used when laser welding the Ti6Al4V titanium alloys vertically. PMID:28885573

  7. Study of Gravity Effects on Titanium Laser Welding in the Vertical Position.

    PubMed

    Chang, Baohua; Yuan, Zhang; Pu, Haitao; Li, Haigang; Cheng, Hao; Du, Dong; Shan, Jiguo

    2017-09-08

    To obtain satisfactory welds in positional laser beam welding, it is necessary to know how process parameters will influence the quality of welds in different welding positions. In this study, the titanium alloy Ti6Al4V sheets were laser welded in two vertical welding positions (vertical up and vertical down), and the appearance, porosity, strength, and ductility of the laser joints were evaluated. Results show that undercuts of the vertical up welds were greater than that of vertical down welds, while the porosity contents were much higher in vertical down welds than that in vertical up welds. When welding with a higher heat input, the vertical up welding position resulted in poor weld profiles (undercuts and burn-through holes), whereas the vertical down welding position led to excessive porosity contents in welds. Both severe undercut and excessive porosity were detrimental to the tensile properties of the welds. Weld appearance was improved and porosity contents were reduced by using a lower heat input, achieving better weld quality. Therefore, it is suggested that process parameter settings with relatively high laser powers and welding speeds, which can result in lower heat inputs, are used when laser welding the Ti6Al4V titanium alloys vertically.

  8. [Spectra and thermal analysis of the arc in activating flux plasma arc welding].

    PubMed

    Chai, Guo-Ming; Zhu, Yi-Feng

    2010-04-01

    In activating flux plasma arc welding the welding arc was analyzed by spectra analysis technique, and the welding arc temperature field was measured by the infrared sensing and computer image technique. The distribution models of welding arc heat flow density of activating flux PAW welding were developed. The composition of welding arc affected by activated flux was studied, and the welding arc temperature field was studied. The results show that the spectral lines of argon atom and ionized argon atom of primary ionization are the main spectra lines of the conventional plasma welding arc. The spectra lines of weld metal are inappreciable in the spectra lines of the conventional plasma welding arc. The gas particle is the main in the conventional plasma welding arc. The conventional plasma welding arc is gas welding arc. The spectra lines of argon atom and ionized argon atom of primary ionization are intensified in the activating flux plasma welding arc, and the spectra lines of Ti, Cr and Fe elements are found in the activating flux plasma welding arc. The welding arc temperature distribution in activating flux plasma arc welding is compact, the outline of the welding arc temperature field is narrow, the range of the welding arc temperature distribution is concentrated, the welding arc radial temperature gradient is large, and the welding arc radial temperature gradient shows normal Gauss distribution.

  9. Parametric optimisation and microstructural analysis on high power Yb-fibre laser welding of Ti-6Al-4V

    NASA Astrophysics Data System (ADS)

    Ahn, J.; Chen, L.; Davies, C. M.; Dear, J. P.

    2016-11-01

    In this work thin sheets of Ti-6Al-4V were full penetration welded using a 5 kW fibre laser in order to evaluate the effectiveness of high power fibre laser as a welding processing tool for welding Ti-6Al-4V with the requirements of the aircraft industry and to determine the effect of welding parameters including laser power, welding speed and beam focal position on the weld microstructure, bead profile and weld quality. It involved establishing an understanding of the influence of welding parameters on microstructural change, welding defects, and the characteristics of heat affected zone (HAZ) and weld metal (WM) of fibre laser welded joints. The optimum range of welding parameters which produced welds without cracking and porosity were identified. The influence of the welding parameters on the weld joint heterogeneity was characterised by conducting detailed microstructural analysis.

  10. Comparing Laser Welding Technologies with Friction Stir Welding for Production of Aluminum Tailor-Welded Blanks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hovanski, Yuri; Carsley, John; Carlson, Blair

    2014-01-15

    A comparison of welding techniques was performed to determine the most effective method for producing aluminum tailor-welded blanks for high volume automotive applications. Aluminum sheet was joined with an emphasis on post weld formability, surface quality and weld speed. Comparative results from several laser based welding techniques along with friction stir welding are presented. The results of this study demonstrate a quantitative comparison of weld methodologies in preparing tailor-welded aluminum stampings for high volume production in the automotive industry. Evaluation of nearly a dozen welding variations ultimately led to down selecting a single process based on post-weld quality and performance.

  11. Welding of Thin Steel Plates by Hybrid Welding Process Combined TIG Arc with YAG Laser

    NASA Astrophysics Data System (ADS)

    Kim, Taewon; Suga, Yasuo; Koike, Takashi

    TIG arc welding and laser welding are used widely in the world. However, these welding processes have some advantages and problems respectively. In order to improve problems and make use of advantages of the arc welding and the laser welding processes, hybrid welding process combined the TIG arc with the YAG laser was studied. Especially, the suitable welding conditions for thin steel plate welding were investigated to obtain sound weld with beautiful surface and back beads but without weld defects. As a result, it was confirmed that the shot position of the laser beam is very important to obtain sound welds in hybrid welding. Therefore, a new intelligent system to monitor the welding area using vision sensor is constructed. Furthermore, control system to shot the laser beam to a selected position in molten pool, which is formed by TIG arc, is constructed. As a result of welding experiments using these systems, it is confirmed that the hybrid welding process and the control system are effective on the stable welding of thin stainless steel plates.

  12. GTA welding and heat treating of high purity aluminum. [-452/sup 0/F

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voigt, R.C.; Loper, C.R. Jr.

    1979-01-01

    Gas tungsten arc welding is a suitable way to join high purity aluminum with only small increases in the electrical resistivity at 4.2 K (i.e., -269 C or -452 F) if proper welding procedures are used. High purity aluminum weld zone properties, useful for the design of cryogenic superconducting devices, are now available. The additional electrical resistivity caused by welding is independent of original base metal resistivity and can be decreased significantly by heat treatments as low as 260 C (500 F) for 30 minutes. Tungsten contamination caused from welding is small (on the order of 0.2 ppM) but itmore » is a significant contribution to weld zone resistivity. This suggests that other welding techniques such as laser welding or electron beam welding may be successful alternatives. Additional GTA welding tests for various welding conditions and welding procedures would lead to a greater understanding of the tungsten emission levels during welding. Perturbations during GTA welding such as electrode spitting or electrode contact with the weld metal must be eliminated to successfully weld high purity aluminum. Improper welding techniques causing arc instabilities, for any reason, cause highly resistive welds that must be properly repaired.« less

  13. The technology and welding joint properties of hybrid laser-tig welding on thick plate

    NASA Astrophysics Data System (ADS)

    Shenghai, Zhang; Yifu, Shen; Huijuan, Qiu

    2013-06-01

    The technologies of autogenous laser welding and hybrid laser-TIG welding are used on thick plate of high strength lower alloy structural steel 10CrNiMnMoV in this article. The unique advantages of hybrid laser-TIG welding is summarized by comparing and analyzing the process parameters and welding joints of autogenous laser welding laser welding and hybrid laser-TIG welding. With the optimal process parameters of hybrid welding, the good welding joint without visible flaws can be obtained and its mechanical properties are tested according to industry standards. The results show that the hybrid welding technology has certain advantages and possibility in welding thick plates. It can reduce the demands of laser power, and it is significant for lowering the aspect ratio of weld during hybrid welding, so the gas in the molten pool can rise and escape easily while welding thick plates. Therefore, the pores forming tendency decreases. At the same time, hybrid welding enhances welding speed, and optimizes the energy input. The transition and grain size of the microstructure of hybrid welding joint is better and its hardness is higher than base material. Furthermore, its tensile strength and impact toughness is as good as base material. Consequently, the hybrid welding joint can meet the industry needs completely.

  14. Parent artery occlusion for ruptured "true" posterior communicating artery aneurysm.

    PubMed

    Mitsuhashi, Takashi; Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-04-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgical clipping over endovascular coil embolization. Endovascular treatment may be a good alternative to surgical trapping for true PCoA blister aneurysm. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Penetrating Atherosclerotic Ulcer of the Abdominal Aorta Involving the Celiac Trunk Origin and Superior Mesenteric Artery Occlusion: Endovascular Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Petrocelli, Francesco

    We describe a case of endovascular treatment in a 64-year-old woman affected by a penetrating atherosclerotic ulcer (PAU) of the abdominal aorta with a 26-mm pseudoaneurysm involving the celiac trunk (CT) origin and with superior mesenteric artery (SMA) occlusion in the first 30 mm. The patient underwent stenting to treat the SMA occlusion and subsequent deployment of a custom-designed fenestrated endovascular stent-graft to treat the PAU involving the CT origin. Follow-up at 6 months after device placement demonstrated no complications, and there was complete thrombosis of the PAU and patency of the two branch vessels.

  16. Congenital intrahepatic portosystemic venous shunt and liver mass in a child patient: successful endovascular treatment with an amplatzer vascular plug (AVP).

    PubMed

    Lee, Sae Ah; Lee, Young Seok; Lee, Kun Song; Jeon, Gyeong Sik

    2010-01-01

    A congenital intrahepatic portosystemic shunt is a rare anomaly; but, the number of diagnosed cases has increased with advanced imaging tools. Symptomatic portosystemic shunts, especially those that include hyperammonemia, should be treated; and various endovascular treatment methods other than surgery have been reported. Hepatic masses with either an intra- or extrahepatic shunt also have been reported, and the mass is another reason for treatment. Authors report a case of a congenital intrahepatic portosystemic shunt with a hepatic mass that was successfully treated using a percutaneous endovascular approach with vascular plugs. By the time the first short-term follow-up was conducted, the hepatic mass had disappeared.

  17. Endovascular retrieval of dental needle retained in the internal carotid artery.

    PubMed

    Moore, Kenneth; Khan, Nickalus R; Michael, L Madison; Arthur, Adam S; Hoit, Daniel

    2017-03-08

    Intravascular foreign bodies are a known complication of medical and dental procedures. Dental anesthetic needles may be broken off and retained in the oropharynx. These needles have occasionally been reported to migrate through the oral mucosa in to deeper structures. Here we present the case of a 57-year-old man who had a retained dental needle that had migrated into his internal carotid artery. The needle was removed using endovascular techniques. To our knowledge, this is the first report of a retained dental needle being retrieved using this method. We review the literature on intravascular foreign bodies, retained dental needles, and endovascular techniques for retrieval of such foreign bodies. 2017 BMJ Publishing Group Ltd.

  18. Endovascular Interventions for Acute and Chronic Lower Extremity Deep Venous Disease: State of the Art.

    PubMed

    Sista, Akhilesh K; Vedantham, Suresh; Kaufman, John A; Madoff, David C

    2015-07-01

    The societal and individual burden caused by acute and chronic lower extremity venous disease is considerable. In the past several decades, minimally invasive endovascular interventions have been developed to reduce thrombus burden in the setting of acute deep venous thrombosis to prevent both short- and long-term morbidity and to recanalize chronically occluded or stenosed postthrombotic or nonthrombotic veins in symptomatic patients. This state-of-the-art review provides an overview of the techniques and challenges, rationale, patient selection criteria, complications, postinterventional care, and outcomes data for endovascular intervention in the setting of acute and chronic lower extremity deep venous disease. Online supplemental material is available for this article.

  19. Endovascular Treatment of a Symptomatic Thoracoabdominal Aortic Aneurysm by Chimney and Periscope Techniques for Total Visceral and Renal Artery Revascularization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cariati, Maurizio, E-mail: cariati.maurizio@sancarlo.mi.it; Mingazzini, Pietro; Dallatana, Raffaello

    2013-05-02

    Conventional endovascular therapy of thoracoabdominal aortic aneurysm with involving visceral and renal arteries is limited by the absence of a landing zone for the aortic endograft. Solutions have been proposed to overcome the problem of no landing zone; however, most of them are not feasible in urgent and high-risk patients. We describe a case that was successfully treated by total endovascular technique with a two-by-two chimney-and-periscope approach in a patient with acute symptomatic type IV thoracoabdominal aortic aneurysm with supra-anastomotic aneurysm formation involving the renal and visceral arteries and a pseduaneurismatic sac localized in the left ileopsoas muscle.

  20. Friction Stir Welding of Magnesium Alloy Type AZ 31

    NASA Astrophysics Data System (ADS)

    Kupec, Tomáš; Behúlová, Mária; Turňa, Milan; Sahul, Miroslav

    The paper deals with welding of Mg alloy of the type AZ 31 by Friction Stir Welding technology (FSW). The FSW technology is at present predominantly used for welding light metals and alloys, as aluminium, magnesium and their alloys. Experimental part consists of performing the simulation and fabrication of welded joints on a new-installed welding equipment available at the Welding Research Institute — Industrial Institute of SR Bratislava. Welding tools made of tool steel type H 13 were used for welding experiments. Geometry of welding tools was designed on the base of literature knowledge. Suitable welding parameters and conditions were determined using numerical simulation. Main emphasis was laid upon the tool revolutions, welding speed and tool bevel angle. The effect of welding parameters on the quality of welded joints was assessed. Assessment of welded joints was carried out by radiography, light microscopy, hardness measurement and EDX microanalysis. Static tensile test was employed for mechanical testing.

  1. Contribution to applications of EBW in instrument techniques

    NASA Astrophysics Data System (ADS)

    Hrabovsky, Miroslav

    1999-07-01

    The electron beam welding belongs to so-called physical methods of welding and it is utilized to welding of most materials, that can be arc welded. It is of use there, where one taxing welding technics and structure technologyableless heavily. As a rule, the quality of weld is better than at most first-rate welds being done by inert gas shielded arc welding (WIG, Argoarc). In plant instrumentation, where the limitation of any welded material distortion is of extraordinary importance, this way of welding is significant at welding of thermal-treated Cu-Be alloys, used in measurement technics, structural members from Ti alloys and stainless steels in branches of biomedicine and cryotechnics. This technology positives, especially high weld purity, narrow and deep root penetration, high welding rate, together with low energy consumption, lead to applications and verification of optimum operating mode at welding of frequent materials. In the contribution the results of this proofs of selected welded materials from viewpoint of weld quality, their physical-mechanic properties and microhardness, are presented.

  2. Aluminum Lithium Alloy 2195 Fusion Welding Improvements with New Filler Wire

    NASA Technical Reports Server (NTRS)

    Russell, Carolyn; Bjorkman, Gerry; McCool, Carolyn (Technical Monitor)

    2000-01-01

    A viewgraph presentation outlines NASA Marshall Space Flight Center, Lockheed Martin Michoud Space Systems, and McCook Metals' development an aluminum-copper weld filler wire for fusion welding 2195 aluminum lithium. The aluminum-copper based weld filler wire has been identified as B218, which is the result of six years of weld filler wire development funded by NASA, Lockheed Martin, and McCook Metals. The Super Lightweight External Tank for the NASA Space Shuttle Program consists of 2195 welded with 4043 aluminum-silicon weld filler wire. The B218 filler wire chemistry was developed to produce enhanced 2195 weld and repair weld mechanical properties. An initial characterization of the B218 weld filler wire was performed consisting of initial weld and repair weld evaluation comparing B218 and 4043. The testing involved room temperature and cryogenic tensile testing along with fracture toughness testing. B218 weld filler wire proved to produce enhanced initial and repair weld tensile and fracture properties over 4043. B218 weld filler wire has proved to be a superior weld filler wire for welding 2195 and other aluminum lithium alloys over 4043.

  3. Fundamentals and advances in the development of remote welding fabrication systems

    NASA Technical Reports Server (NTRS)

    Agapakis, J. E.; Masubuchi, K.; Von Alt, C.

    1986-01-01

    Operational and man-machine issues for welding underwater, in outer space, and at other remote sites are investigated, and recent process developments are described. Probable remote welding missions are classified, and the essential characteristics of fundamental remote welding tasks are analyzed. Various possible operational modes for remote welding fabrication are identified, and appropriate roles for humans and machines are suggested. Human operator performance in remote welding fabrication tasks is discussed, and recent advances in the development of remote welding systems are described, including packaged welding systems, stud welding systems, remotely operated welding systems, and vision-aided remote robotic welding and autonomous welding systems.

  4. Advanced Welding Concepts

    NASA Technical Reports Server (NTRS)

    Ding, Robert J.

    2010-01-01

    Four advanced welding techniques and their use in NASA are briefly reviewed in this poster presentation. The welding techniques reviewed are: Solid State Welding, Friction Stir Welding (FSW), Thermal Stir Welding (TSW) and Ultrasonic Stir Welding.

  5. Soldadura (Welding). Spanish Translations for Welding.

    ERIC Educational Resources Information Center

    Hohhertz, Durwin

    Thirty transparency masters with Spanish subtitles for key words are provided for a welding/general mechanical repair course. The transparency masters are on such topics as oxyacetylene welding; oxyacetylene welding equipment; welding safety; different types of welds; braze welding; cutting torches; cutting with a torch; protective equipment; arc…

  6. Numerical and experimental determination of weld pool shape during high-power diode laser welding

    NASA Astrophysics Data System (ADS)

    Klimpel, Andrzej; Lisiecki, Aleksander; Szymanski, Andrzej; Hoult, Anthony P.

    2003-10-01

    In this paper, results of investigations on the shape of weld pool during High Power Diode Laser (HPDL) welding are presented. The results of tests showed that the shape of weld pool and mechanism of laser welding with a rectangular pattern of 808 nm laser radiation differs distinctly from previous laser welding mechanisms. For all power densities the conduction mode welds were observed and weld pool geometry depends significantly on the welding parameters.

  7. Endobag separation - an ominous sign after endovascular aneurysm sealing with the Nellix device.

    PubMed

    Tasleem, Sadia; Badri, Hassan; Ranjeet, Narlawar; Antoniou, George A

    2018-06-01

    Our report aims to alert physicians performing endovascular aneurysm sealing with the Nellix endoprosthesis to the risk of rupture when endobag separation is noticed on computed tomography. Endobag separation when observed with acute presentation of abdominal pain is an indicator of imminent rupture and prompt interventional treatment should be undertaken.

  8. A Rare Complication of TEVAR Performed for Complex Acute Stanford B Aortic Dissection.

    PubMed

    Awad, George; Zardo, Patrick; Baraki, Hassina; Kutschka, Ingo

    2017-01-01

    Management of aortic dissection with a novel endovascular technique known as thoracic endovascular aortic repair (TEVAR) paired with surgical debranching as a less invasive alternative to conventional repair has gained widespread acceptance. However, experience for complicated, Stanford type B dissection involving the aortic arch is still limited.

  9. 77 FR 8117 - Medical Devices; Cardiovascular Devices; Classification of the Endovascular Suturing System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-14

    ... Administration (FDA) is classifying the endovascular suturing system into class II (special controls). The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance..., or FDA issues an order finding the device to be substantially equivalent, in accordance with section...

  10. A Brief Introduction to the Theory of Friction Stir Welding

    NASA Technical Reports Server (NTRS)

    Nunes, Arthur C., Jr.

    2008-01-01

    Friction stir welding (FSW) is a solid state welding process invented in 1991 at The Welding Institute in the United Kingdom. A weld is made in the FSW process by translating a rotating pin along a weld seam so as to stir the sides of the seam together. FSW avoids deleterious effects inherent in melting and is already an important welding process for the aerospace industry, where welds of optimal quality are demanded. The structure of welds determines weld properties. The structure of friction stir welds is determined by the flow field in the weld metal in the vicinity of the weld tool. A simple kinematic model of the FSW flow field developed at Marshall Space Flight Center, which enables the basic features of FSW microstructure to be understood and related to weld process parameters and tool design, is explained.

  11. Welding Penetration Control of Fixed Pipe in TIG Welding Using Fuzzy Inference System

    NASA Astrophysics Data System (ADS)

    Baskoro, Ario Sunar; Kabutomori, Masashi; Suga, Yasuo

    This paper presents a study on welding penetration control of fixed pipe in Tungsten Inert Gas (TIG) welding using fuzzy inference system. The welding penetration control is essential to the production quality welds with a specified geometry. For pipe welding using constant arc current and welding speed, the bead width becomes wider as the circumferential welding of small diameter pipes progresses. Having welded pipe in fixed position, obviously, the excessive arc current yields burn through of metals; in contrary, insufficient arc current produces imperfect welding. In order to avoid these errors and to obtain the uniform weld bead over the entire circumference of the pipe, the welding conditions should be controlled as the welding proceeds. This research studies the intelligent welding process of aluminum alloy pipe 6063S-T5 in fixed position using the AC welding machine. The monitoring system used a charge-coupled device (CCD) camera to monitor backside image of molten pool. The captured image was processed to recognize the edge of molten pool by image processing algorithm. Simulation of welding control using fuzzy inference system was constructed to simulate the welding control process. The simulation result shows that fuzzy controller was suitable for controlling the welding speed and appropriate to be implemented into the welding system. A series of experiments was conducted to evaluate the performance of the fuzzy controller. The experimental results show the effectiveness of the control system that is confirmed by sound welds.

  12. Direct access to the middle meningeal artery for embolization of complex dural arteriovenous fistula: a hybrid treatment approach

    PubMed Central

    Lin, Ning; Brouillard, Adam M; Mokin, Maxim; Natarajan, Sabareesh K; Snyder, Kenneth V; Levy, Elad I; Siddiqui, Adnan H

    2014-01-01

    Endovascular embolization has become increasingly favored over microsurgical resection for treatment of complex dural arteriovenous fistulas (DAVFs). However, endovascular treatment can be restricted by tortuous transarterial access and a transvenous approach is not always feasible. We present a Borden III DAVF treated by direct access to the middle meningeal artery (MMA) and Onyx embolization performed in a hybrid operating room–angiography suite. A middle-aged patient with pulsatile headaches was found to have left transverse sinus occlusion and DAVF with retrograde cortical venous drainage fed by multiple external carotid artery (ECA) feeders. Endovascular attempts via conventional transvenous and transarterial routes were unsuccessful, and the major MMA feeder was accessed directly after temporal craniotomy was performed under neuronavigation. Onyx embolization was performed; complete occlusion of the fistula was achieved. Three-month follow-up angiography showed no residual filling; the patient remains complication-free. A combined surgical–endovascular technique in a hybrid operating room–angiography suite can be an effective treatment for DAVFs complicated by inaccessible arterial and transvenous approaches. PMID:24903968

  13. Flexible robotic catheters in the visceral segment of the aorta: advantages and limitations.

    PubMed

    Li, Mimi M; Hamady, Mohamad S; Bicknell, Colin D; Riga, Celia V

    2018-06-01

    Flexible robotic catheters are an emerging technology which provide an elegant solution to the challenges of conventional endovascular intervention. Originally developed for interventional cardiology and electrophysiology procedures, remotely steerable robotic catheters such as the Magellan system enable greater precision and enhanced stability during target vessel navigation. These technical advantages facilitate improved treatment of disease in the arterial tree, as well as allowing execution of otherwise unfeasible procedures. Occupational radiation exposure is an emerging concern with the use of increasingly complex endovascular interventions. The robotic systems offer an added benefit of radiation reduction, as the operator is seated away from the radiation source during manipulation of the catheter. Pre-clinical studies have demonstrated reduction in force and frequency of vessel wall contact, resulting in reduced tissue trauma, as well as improved procedural times. Both safety and feasibility have been demonstrated in early clinical reports, with the first robot-assisted fenestrated endovascular aortic repair in 2013. Following from this, the Magellan system has been used to successfully undertake a variety of complex aortic procedures, including fenestrated/branched endovascular aortic repair, embolization, and angioplasty.

  14. Clinical Features and Endovascular Management of Iliac Artery Fibromuscular Dysplasia

    PubMed Central

    Ketha, Siva S.; Bjarnason, Haraldur; Oderich, Gustavo S.; Misra, Sanjay

    2014-01-01

    Purpose To identify the spectrum of clinical presentation of iliac artery fibromuscular dysplasia (FMD) and to evaluate the outcomes of endovascular management of iliac FMD for claudication. Methods and materials All patients in our institution with a diagnosis of FMD between January 1980 and December 2010 were identified. 14 patients were found to have FMD of the iliac arteries. Associated risk factors included hypertension (79%), hyperlipidemia (64%), smoking history (36%), coronary artery disease (21%), diabetes (0 %), and obesity (36%). Results Eight (57%) patients were incidentally found to have iliac FMD on imaging. 6 (43%) patients had life style limiting claudication involving one or both extremities. All 6 patients were reported as mild peripheral arterial disease (PAD) based on ankle brachial index (ABI) measurements (0.7 to 0.9). These six patients underwent 10 endovascular procedures for claudication including angioplasty (n=8) and self-expanding stent placement (n=2). Mean symptom free survival was 56.3 months. Conclusion Iliac FMD may be found incidentally or may present with disabling claudication that is amenable to endovascular treatment. PMID:24768236

  15. Interventional radiology in bone metastases.

    PubMed

    Chiras, J; Shotar, E; Cormier, E; Clarençon, F

    2017-11-01

    Interventional radiology plays a significant role in the treatment of bone metastases by various techniques, percutaneous or endovascular. Vertebroplasty is the most well-studied technique for stabilisation of spine metastases as it induces satisfactory stabilisation of the vertebra and offers clear improvement of the quality of life. Due to the success of this technique cementoplasty of other bones, mainly pelvic girdle, has been largely developed. The development of reinforced cementoplasty allows treatment of pre-fractural osteolysis of some long bones. The heat due to the polymerisation of the cement induces carcinolytic effect but this effect is not as important as that which results from radiofrequency destruction. This last technique appears currently as the most important development to definitively destroy bone metastases and is progressively replacing percutaneous alcoholic destruction of such lesions. Angiographic techniques, such as endovascular embolisation, can also be very useful to reduce the risk of surgical treatment of hyper vascular metastases. Chemoembolisation is currently developed to associate pain relief induced by Endovascular embolisation and the carcinolytic effect obtained by local endovascular chemotherapy. All these techniques should develop largely during the next years. © 2017 John Wiley & Sons Ltd.

  16. [Interventional radiology in bone metastases].

    PubMed

    Chiras, Jacques; Cormier, Evelyne; Baragan, Hector; Jean, Betty; Rose, Michèle

    2007-02-01

    Interventional radiology takes a large place in the treatment of bone metastases by numerous techniques, percutaneous or endovascular. Vertebroplasty appears actually as the most important technique for stabilisation of spine metastases as it induces satisfactory stabilisation of the vertebra and offer clear improvement of the quality of life. Due to the success of this technique cementoplasty of other bones, mainly pelvic girdle, largely develop. The heath due to the polymerisation of the cement induce carcinolytic effect but this effect is not as important as that can be created with radiofrequency destruction. This last technique appears actually as the most important development to destroy definitively some bone metastases and replace progressively alcoholic destruction of such lesions. Angiographic techniques appear more confidential but endovascular embolization is very useful to diminish the risk of surgical treatment of hyper vascular metastases. Chemoembolization is actually developped to associate the relief of pain induced by endovascular embolization and the carcinolytic effect obtained by local endovascular chemotherapy. All these techniques should develop largely during the next years and their efficacy and safety should improve largely by treating earlier the metastasis.

  17. Indications for the Performance of Intracranial Endovascular Neurointerventional Procedures: A Scientific Statement From the American Heart Association.

    PubMed

    Eskey, Clifford J; Meyers, Philip M; Nguyen, Thanh N; Ansari, Sameer A; Jayaraman, Mahesh; McDougall, Cameron G; DeMarco, J Kevin; Gray, William A; Hess, David C; Higashida, Randall T; Pandey, Dilip K; Peña, Constantino; Schumacher, Hermann C

    2018-05-22

    Intracranial endovascular interventions provide effective and minimally invasive treatment of a broad spectrum of diseases. This area of expertise has continued to gain both wider application and greater depth as new and better techniques are developed and as landmark clinical studies are performed to guide their use. Some of the greatest advances since the last American Heart Association scientific statement on this topic have been made in the treatment of ischemic stroke from large intracranial vessel occlusion, with more effective devices and large randomized clinical trials showing striking therapeutic benefit. The treatment of cerebral aneurysms has also seen substantial evolution, increasing the number of aneurysms that can be treated successfully with minimally invasive therapy. Endovascular therapies for such other diseases as arteriovenous malformations, dural arteriovenous fistulas, idiopathic intracranial hypertension, venous thrombosis, and neoplasms continue to improve. The purpose of the present document is to review current information on the efficacy and safety of procedures used for intracranial endovascular interventional treatment of cerebrovascular diseases and to summarize key aspects of best practice. © 2018 American Heart Association, Inc.

  18. 49 CFR 195.228 - Welds and welding inspection: Standards of acceptability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welds and welding inspection: Standards of... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Construction § 195.228 Welds and welding inspection: Standards of acceptability. (a) Each weld and welding must be inspected to insure compliance with...

  19. 49 CFR 195.228 - Welds and welding inspection: Standards of acceptability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Welds and welding inspection: Standards of... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Construction § 195.228 Welds and welding inspection: Standards of acceptability. (a) Each weld and welding must be inspected to insure compliance with...

  20. 49 CFR 195.228 - Welds and welding inspection: Standards of acceptability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Welds and welding inspection: Standards of... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Construction § 195.228 Welds and welding inspection: Standards of acceptability. (a) Each weld and welding must be inspected to insure compliance with...

  1. 49 CFR 195.228 - Welds and welding inspection: Standards of acceptability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Welds and welding inspection: Standards of... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Construction § 195.228 Welds and welding inspection: Standards of acceptability. (a) Each weld and welding must be inspected to insure compliance with...

  2. 49 CFR 195.228 - Welds and welding inspection: Standards of acceptability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Welds and welding inspection: Standards of... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Construction § 195.228 Welds and welding inspection: Standards of acceptability. (a) Each weld and welding must be inspected to insure compliance with...

  3. Research and application of self - propagating welding technology

    NASA Astrophysics Data System (ADS)

    Ma, Yunhe; Li, Zhizun; Wang, Jianjiang; Sun, Liming

    2018-04-01

    Self-propagating welding is an important application area of self-propagating high-temperature synthesis technology (SHS technology), suitable for special environment and special materials welding. This paper briefly introduces the principle of self - propagating welding and its technical characteristics, and briefly summarizes the current research and application of SHS welding around three aspects of thin film welding, welding of refractory welding and emergency welding of battlefield.

  4. Mid-term Results of Endovascular Treatment for Infrarenal Aortic Stenosis and Occlusion.

    PubMed

    Sohgawa, Etsuji; Sakai, Yukimasa; Nango, Mineyoshi; Cho, Hisayuki; Jogo, Atsushi; Hamamoto, Shinichi; Yamamoto, Akira; Miki, Yukio

    2015-06-01

    Focal stenosis or occlusion of the infrarenal aorta is rare, and treatment is usually conventional bypass or endarterectomy. However, endovascular treatment has advanced in recent years. The purpose of this retrospective study is to report the results of primary stenting for focal infrarenal aortic occlusive disease and clarify the usefulness of endovascular treatment. This study includes 6 consecutive patients (3 men, 3 women; mean age, 59.3 years) with infrarenal aortic stenosis or occlusion who underwent endovascular intervention at our hospital between April 2009 and February 2014. All patients had bilateral intermittent claudication. The mean preoperative ankle-brachial index (ABI) showed a slight to moderate decrease: right 0.668 and left 0.636. The mean lesion site length was 12.5 mm, the percent stenosis was 90.7%, and calcification was present in 3 patients. Primary stenting was performed in all patients. The stent selected was generally a self-expanding stent (SES). For patients with severe calcification, the stent selected was a balloon-expandable stent (BES). Four patients received an SES and two patients received a BES. The technical success rate was 100%, no complications occurred, and the mean pressure gradient disappeared or decreased. Symptoms resolved in all patients and the postoperative ABI improved: right 0.923 and left 0.968. During a mean follow-up period of 27 months, there were no recurrent symptoms and no restenosis on CT angiography. Endovascular treatment should be considered as a first line treatment for focal infrarenal aortic stenosis and occlusion.

  5. Evidence-based medicine and contemporary certification: Analysis of the American Board of Vascular Medicine endovascular board examination.

    PubMed

    Slovut, David Paul; Gray, Bruce H; Saiar, Amin; Bates, Mark C

    2017-08-01

    Since 2005, the American Board of Vascular Medicine (ABVM) endovascular examination has been used to certify vascular practitioners. Annual rigorous review has confirmed it is psychometrically valid and reliable. However, the evidence basis underlying the examination items has not been studied systematically. The aim of this study was to adjudicate class of recommendation (COR) and level of evidence (LOE) for the 2015 ABVM endovascular examination and establish an additional feedback mechanism for examination improvement based on contemporary evidence-based guidelines. We performed a pooled consensus process to classify each of the 110 items in the 2015 ABVM endovascular examination by COR and LOE as detailed in the current guideline statements. We added additional categories for items that were not eligible for assignment using traditional current evidence-based metrics: 'COR X', cannot be determined, not applicable, or simple recognition; and 'LOE X', cannot be determined or not applicable. COR classifications were assigned in the following proportion: Class I=15%, Class II=40%, Class III=3%, COR X=42%. LOE classifications were assigned in the following proportion: Level A=12%, Level B=34%, Level C=32%, LOE X=22%. Our analysis showed that nearly half of the 2015 ABVM endovascular examination items were supported by strong scientific evidence or fact-based knowledge. COR and LOE analysis yielded notably different results. Use of alternate classification schema may be powerful tools for improving certification exams in healthcare.

  6. Contemporary Strategies in the Management of Civilian Abdominal Vascular Trauma

    PubMed Central

    Karaolanis, Georgios; Moris, Dimitrios; McCoy, C. Cameron; Tsilimigras, Diamantis I.; Georgopoulos, Sotirios; Bakoyiannis, Chris

    2018-01-01

    The evaluation and management of patients with abdominal vascular trauma or injury requires immediate and effective decision-making in these unfavorable circumstances. The majority of these patients arrive at trauma centers in profound shock, secondary to massive blood loss, which is often unrelenting. Moreover, ischemia, compartment syndrome, thrombosis, and embolization may also be life threatening and require immediate intervention. To minimize the risk of these potentially lethal complications, early understanding of the disease process and emergent therapeutic intervention are necessary. In the literature, the management of acute traumatic vascular injuries is restricted to traditional open surgical techniques. However, in penetrating injuries surgeons often face a potentially contaminated field, which renders the placement of prosthetic grafts inappropriate. Currently, however, there are sparse data on the management of vascular trauma with endovascular techniques. The role of endovascular technique in penetrating abdominal vascular trauma, which is almost always associated with severe active bleeding, is limited. It is worth mentioning that hybrid operating rooms with angiographic radiology capabilities offer more opportunities for the management of this kind of injuries by either temporary control of the devastating bleeding using endovascular balloon tamponade or with embolization and stenting. On the other hand, blunt abdominal injuries are less dangerous and they could be treated at most times by endovascular means. Since surgeons continue to encounter abdominal vascular trauma, open and endovascular techniques will evolve constantly giving us encouraging messages for the near future. PMID:29516005

  7. National Institutes of Health Stroke Scale-Time Score Predicts Outcome after Endovascular Therapy in Acute Ischemic Stroke: A Retrospective Single-Center Study.

    PubMed

    Todo, Kenichi; Sakai, Nobuyuki; Kono, Tomoyuki; Hoshi, Taku; Imamura, Hirotoshi; Adachi, Hidemitsu; Kohara, Nobuo

    2016-05-01

    Outcomes after successful endovascular therapy in acute ischemic stroke are associated with onset-to-reperfusion time (ORT) and the National Institutes of Health Stroke Scale (NIHSS) score. In intravenous recombinant tissue plasminogen activator therapy, the NIHSS-time score, calculated by multiplying onset-to-treatment time with the NIHSS score, has been shown to predict clinical outcomes. In this study, we assessed whether a similar combination of the ORT and the NIHSS score can be applied to predict the outcomes after endovascular therapy. We retrospectively reviewed the charts of 128 consecutive ischemic stroke patients with successful reperfusion after endovascular therapy. We analyzed the association of the ORT, the NIHSS score, and the NIHSS-time score with good outcome (modified Rankin Scale score ≤ 2 at 3 months). Good outcome rates for patients with NIHSS-time scores of 84.7 or lower, scores higher than 84.7 up to 127.5 or lower, and scores higher than 127.5 were 72.1%, 44.2%, and 14.3%, respectively (P < .01). Multivariate logistic regression analysis revealed that the NIHSS-time score was an independent predictor of good outcomes (odds ratio, .372; 95% confidence interval, .175-.789) after adjusting for age, sex, internal carotid artery occlusion, plasma glucose level, ORT, and NIHSS score. The NIHSS-time score can predict good clinical outcomes after endovascular treatment. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  8. Critical early thrombolytic and endovascular reperfusion therapy for acute ischemic stroke victims: a call for adjunct neuroprotection.

    PubMed

    Lapchak, Paul A

    2015-10-01

    Today, there is an enormous amount of excitement in the field of stroke victim care due to the recent success of MR. CLEAN, SWIFT PRIME, ESCAPE, EXTEND-IA, and REVASCAT endovascular trials. Successful intravenous (IV) recombinant tissue plasminogen activator (rt-PA) clinical trials [i.e., National Institute of Neurological Disorders and Stroke (NINDS) rt-PA trial, Third European Cooperative Acute Stroke Study (ECASSIII), and Third International Stroke study (IST-3)] also need to be emphasized. In the recent endovascular and thrombolytic trials, there is statistically significant improvement using both the National Institutes of Health Stroke Scale (NIHSS) and the modified Rankin Score (mRS) scale, but neither approach promotes complete recovery in patients enrolled within any particular NIHSS or mRS score tier. Absolute improvement (mRS 0-2 at 90 days) with endovascular therapy is 13.5-31 %, whereas thrombolytics alone also significantly improve patient functional independence, but to a lesser degree (NINDS rt-PA trial 13 %). This article has 3 main goals: (1) first to emphasize the utility and cost-effectiveness of rt-PA to treat stroke; (2) second to review the recent endovascular trials with respect to efficacy, safety, and cost-effectiveness as a stroke treatment; and (3) to further consider and evaluate strategies to develop novel neuroprotective drugs. A thesis will be put forth so that future stroke trials and therapy development can optimally promote recovery so that stroke victims can return to "normal" life.

  9. Analysis of risk factors for perifocal oedema after endovascular embolization of unruptured intracranial arterial aneurysms

    PubMed Central

    Lukic, Snezana; Jankovic, Slobodan; Popovic, Katarina Surlan; Bankovic, Dragic; Popovic, Peter; Mijailovic, Milan

    2015-01-01

    Background Endovascular embolization is a treatment of choice for the management of unruptured intracranial aneurysms, but sometimes is complicated with perianeurysmal oedema. The aim of our study was to establish incidence and outcomes of perianeurysmal oedema after endovascular coiling of unruptured intracranial aneurysms, and to reveal possible risk factors for development of this potentially serious complication. Methods In total 119 adult patients with endovascular embolization of unruptured intracranial aneurysm (performed at Department for Interventional Neuroradiology, Clinical Center, Kragujevac, Serbia) were included in our study. The embolizations were made by electrolite-detachable platinum coils: pure platinum, hydrophilic and combination of platinum and hydrophilic coils. Primary outcome variable was perianeurysmal oedema visualized by magnetic resonance imaging (MRI) 7, 30 and 90 days after the embolization. Results The perianurysmal oedema appeared in 47.6% of patients treated with hydrophilic coils, in 21.6% of patients treated with platinum coils, and in 53.8% of those treated with mixed type of the coils. The multivariate logistic regression showed that variables associated with occurrence of perianeurysmal oedema are volume of the aneurysm, hypertension, diabetes and smoking habit. Hypertension is the most important independent predictor of the perianeurysmal oedema, followed by smoking and diabetes. Conclusions The results of our study suggest that older patients with larger unruptured intracranial aneurysms, who suffer from diabetes mellitus and hypertension, and have the smoking habit, are under much higher risk of having perianeurysmal oedema after endovascular coiling. PMID:26834520

  10. Endovascular Mechanical Thrombectomy in Basilar Artery Occlusion: Initial Experience

    PubMed Central

    Park, Bum-Soo; Kwon, Hyon-Jo; Choi, Seung-Won; Kim, Seon-Hwan; Koh, Hyeon-Song; Youm, Jin-Young; Song, Shi-Hun

    2013-01-01

    Objective This study was conducted to assess the efficacy and safety of endovascular mechanical thrombectomy (EMT) for patients diagnosed with basilar artery (BA) occlusion. Materials and Methods We retrospectively analyzed clinical and imaging data of 16 patients diagnosed with BA occlusion who were treated with endovascular intervention from July 2012 to February 2013. Direct suction using the Penumbra system and thrombus retrieval by the Solitaire stent were the main endovascular techniques used to restore BA flow. The outcomes were evaluated based on rate of angiographic recanalization, rate of improvement of National Institutes of Health Stroke Scale (NIHSS) score, rate of modified Rankin Scale (mRS) at discharge and after 3 months, and rate of cerebral hemorrhagic complications. Successful recanalization was defined as achieving Thrombolysis In Cerebral Infarction (TICI) of II or III. Results Sixteen patients received thrombectomy. The mean age was 67.8 ± 11 years and the mean NIHSS score was 12.3 ± 8.2. Eight patients treated within 6 hours of symptom onset were grouped as A and the other 8 patients treated beyond 6 hours (range, 6-120) were grouped as B. Successful recanalization was met in six patients (75%) for group A and 7 (87.5%) for group B. Favorable outcome occurred in 4 patients (50%) for group A and 5 (62.5%) for group B. Conclusion Our study supports the effectiveness and safety of endovascular mechanical thrombectomy in treating BA occlusion even 6 hours after symptom onset. PMID:24167791

  11. Society for Neuroscience in Anesthesiology and Critical Care Expert consensus statement: anesthetic management of endovascular treatment for acute ischemic stroke*: endorsed by the Society of NeuroInterventional Surgery and the Neurocritical Care Society.

    PubMed

    Talke, Pekka O; Sharma, Deepak; Heyer, Eric J; Bergese, Sergio D; Blackham, Kristine A; Stevens, Robert D

    2014-04-01

    Literature on the anesthetic management of endovascular treatment of acute ischemic stroke (AIS) is limited. Anesthetic management during these procedures is still mostly dependent on individual or institutional preferences. Thus, the Society of Neuroscience in Anesthesiology and Critical Care (SNACC) created a task force to provide expert consensus recommendations on anesthetic management of endovascular treatment of AIS. The task force conducted a systematic literature review (up to August 2012). Because of the limited number of research articles relating to this subject, the task force solicited opinions from experts in this area. The task force created a draft consensus statement based on the available data. Classes of recommendations and levels of evidence were assigned to articles specifically addressing anesthetic management during endovascular treatment of stroke using the standard American Heart Association evidence rating scheme. The draft consensus statement was reviewed by the Task Force, SNACC Executive Committee and representatives of Society of NeuroInterventional Surgery (SNIS) and Neurocritical Care Society (NCS) reaching consensus on the final document. For this consensus statement the anesthetic management of endovascular treatment of AIS was subdivided into 12 topics. Each topic includes a summary of available data followed by recommendations. This consensus statement is intended for use by individuals involved in the care of patients with acute ischemic stroke, such as anesthesiologists, interventional neuroradiologists, neurologists, neurointensivists, and neurosurgeons.

  12. Republished: Society for Neuroscience in Anesthesiology and Critical Care expert consensus statement: Anesthetic management of endovascular treatment for acute ischemic stroke.

    PubMed

    Talke, Pekka O; Sharma, Deepak; Heyer, Eric J; Bergese, Sergio D; Blackham, Kristine A; Stevens, Robert D

    2014-08-01

    Literature on the anesthetic management of endovascular treatment of acute ischemic stroke (AIS) is limited. Anesthetic management during these procedures is still mostly dependent on individual or institutional preferences. Thus, the Society of Neuroscience in Anesthesiology and Critical Care (SNACC) created a task force to provide expert consensus recommendations on anesthetic management of endovascular treatment of AIS. The task force conducted a systematic literature review (up to August 2012). Because of the limited number of research articles relating to this subject, the task force solicited opinions from experts in this area. The task force created a draft consensus statement based on the available data. Classes of recommendations and levels of evidence were assigned to articles specifically addressing anesthetic management during endovascular treatment of stroke using the standard American Heart Association evidence rating scheme. The draft consensus statement was reviewed by the Task Force, SNACC Executive Committee and representatives of Society of NeuroInterventional Surgery (SNIS) and Neurocritical Care Society (NCS) reaching consensus on the final document. For this consensus statement the anesthetic management of endovascular treatment of AIS was subdivided into 12 topics. Each topic includes a summary of available data followed by recommendations. This consensus statement is intended for use by individuals involved in the care of patients with acute ischemic stroke, such as anesthesiologists, interventional neuroradiologists, neurologists, neurointensivists and neurosurgeons. © 2014 American Heart Association, Inc.

  13. Recent trends in publications of US vascular surgery program directors.

    PubMed

    Hingorani, Anil; DerDerian, Trevor; Gallagher, James; Ascher, Enrico

    2014-08-01

    We reviewed the number of vascular publications listed in PubMed from 2001 to 2009 for US program directors in vascular surgery and suggest that this can be used as a benchmark. PubMed listed 3284 citations published during this time period. The average number of citations in PubMed per program director was 3.68 per year. The top third produced 67% of the publications. Journal of Vascular Surgery publications made up 37%. No statistical differences could be ascertained between the regions of the country and the number of publications. Compared to the first six years, the number of citations decreased during the last three years (13%). During the first period, there were no programs with no publications and seven with no Journal of Vascular Surgery publication. During the last three years, there were seven programs with no publications and 19 programs with no Journal of Vascular Surgery publications. The number of aortic-endovascular citations peaked in 2002 and 2003, while the number of open and basic science citations decreased. Imaging citations peaked in 2003-2005, and carotid-endovascular, vein-endovascular, and thoracic aortic-endovascular citations climbed. The decrease in the number of citations/program/year raises concern about the level of academic activity in vascular surgery. Overall, the annual distribution of the topic of these citations represents a continued shift from open to endovascular cases and decreasing basic science citations. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Endovascular treatment of a blunt aortic injury in Iraq: extension of innovative endovascular capabilities to the modern battlefield.

    PubMed

    Propper, Brandon W; Alley, Joshua B; Gifford, Shaun M; Burkhardt, Gabriel E; Rasmussen, Todd E

    2009-01-01

    The management of blunt descending thoracic aortic injury remains controversial. Despite emerging evidence touting the advantage of endovascular repair in civilian trauma, there have been no reports on the application of this management strategy in the austere environment of war. We provide a case report from the 332nd EMDG/Air Force Theater Hospital, Balad Air Base, Iraq. An Iraqi policeman presented with traumatic aortic disruption following blunt trauma. The patient arrived with hemoperitoneum, a Le Fort III facial fracture, a left humerus fracture, and a thoracic aortic disruption. Following facial packing, fracture stabilization, and damage control laparotomy, aortography was performed, confirming aortic disruption beyond the left subclavian artery. The injury was treated with three aortic cuffs (Gore Excluder AAA Aortic Extender Endoprostheses) placed in sequence from the origin of the left subclavian across the disruption. A type III endoleak was successfully managed with placement of one additional aortic cuff. The patient was discharged after 1 month following the successful treatment of his other injuries. Computed tomography angiography at 10 and 30 days following the procedure revealed no endoleak and a resolved periaortic hematoma. This report details the first endovascular treatment of blunt aortic injury in wartime and represents a sustained commitment to advance innovative endovascular capability closer to the time of injury. Although controversial, this less invasive approach is appealing in patients with high injury severity scores, making its availability in wartime especially germane.

  15. Laser Beam Welding of Nitride Steel Components

    NASA Astrophysics Data System (ADS)

    Gu, Hongping; Yin, Guobin; Shulkin, Boris

    Laser beam welding is a joining technique that has many advantages over conventional GMAW welding, such as low heat input, short cycle time as well as good cosmetic welds. Laser beam welding has been widely used for welding powertrain components in automotive industry. When welding nitride steel components, however, laser beam welding faces a great challenge. The difficulty lies in the fact that the nitride layer in the joint releases the nitrogen into the weld pool, resulting in a porous weld. This research presents an industrial ready solution to prevent the nitrogen from forming gas bubbles in the weld.

  16. Friction plug welding

    NASA Technical Reports Server (NTRS)

    Takeshita, Riki (Inventor); Hibbard, Terry L. (Inventor)

    2001-01-01

    Friction plug welding (FPW) usage is advantageous for friction stir welding (FSW) hole close-outs and weld repairs in 2195 Al--Cu--Li fusion or friction stir welds. Current fusion welding methods of Al--Cu--Li have produced welds containing varied defects. These areas are found by non-destructive examination both after welding and after proof testing. Current techniques for repairing typically small (<0.25) defects weaken the weldment, rely heavily on welders' skill, and are costly. Friction plug welding repairs increase strength, ductility and resistance to cracking over initial weld quality, without requiring much time or operator skill. Friction plug welding while pulling the plug is advantageous because all hardware for performing the weld can be placed on one side of the workpiece.

  17. Design of Friction Stir Spot Welding Tools by Using a Novel Thermal-Mechanical Approach

    PubMed Central

    Su, Zheng-Ming; Qiu, Qi-Hong; Lin, Pai-Chen

    2016-01-01

    A simple thermal-mechanical model for friction stir spot welding (FSSW) was developed to obtain similar weld performance for different weld tools. Use of the thermal-mechanical model and a combined approach enabled the design of weld tools for various sizes but similar qualities. Three weld tools for weld radii of 4, 5, and 6 mm were made to join 6061-T6 aluminum sheets. Performance evaluations of the three weld tools compared fracture behavior, microstructure, micro-hardness distribution, and welding temperature of welds in lap-shear specimens. For welds made by the three weld tools under identical processing conditions, failure loads were approximately proportional to tool size. Failure modes, microstructures, and micro-hardness distributions were similar. Welding temperatures correlated with frictional heat generation rate densities. Because the three weld tools sufficiently met all design objectives, the proposed approach is considered a simple and feasible guideline for preliminary tool design. PMID:28773800

  18. Design of Friction Stir Spot Welding Tools by Using a Novel Thermal-Mechanical Approach.

    PubMed

    Su, Zheng-Ming; Qiu, Qi-Hong; Lin, Pai-Chen

    2016-08-09

    A simple thermal-mechanical model for friction stir spot welding (FSSW) was developed to obtain similar weld performance for different weld tools. Use of the thermal-mechanical model and a combined approach enabled the design of weld tools for various sizes but similar qualities. Three weld tools for weld radii of 4, 5, and 6 mm were made to join 6061-T6 aluminum sheets. Performance evaluations of the three weld tools compared fracture behavior, microstructure, micro-hardness distribution, and welding temperature of welds in lap-shear specimens. For welds made by the three weld tools under identical processing conditions, failure loads were approximately proportional to tool size. Failure modes, microstructures, and micro-hardness distributions were similar. Welding temperatures correlated with frictional heat generation rate densities. Because the three weld tools sufficiently met all design objectives, the proposed approach is considered a simple and feasible guideline for preliminary tool design.

  19. Method and apparatus for assessing weld quality

    DOEpatents

    Smartt, Herschel B.; Kenney, Kevin L.; Johnson, John A.; Carlson, Nancy M.; Clark, Denis E.; Taylor, Paul L.; Reutzel, Edward W.

    2001-01-01

    Apparatus for determining a quality of a weld produced by a welding device according to the present invention includes a sensor operatively associated with the welding device. The sensor is responsive to at least one welding process parameter during a welding process and produces a welding process parameter signal that relates to the at least one welding process parameter. A computer connected to the sensor is responsive to the welding process parameter signal produced by the sensor. A user interface operatively associated with the computer allows a user to select a desired welding process. The computer processes the welding process parameter signal produced by the sensor in accordance with one of a constant voltage algorithm, a short duration weld algorithm or a pulsed current analysis module depending on the desired welding process selected by the user. The computer produces output data indicative of the quality of the weld.

  20. 73rd American Welding Society annual meeting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-01-01

    The volume includes the abstracts of papers presented at the 73rd American Welding Society Annual Meeting. Detailed summaries are given for 118 technical sessions papers discussing computer and control applications in welding, stainless steel, nickel and nickel alloys, weld metal microstructure, shipbuilding, consumables, structural welding, investigations in arc welding and cutting, arc welding processes, weldability testing, piping and tubing, high energy beam welding processes, welding metallurgy of structural steels, new applications, weld metal behavior, NDT certification, aluminum welding, submerged arc welding, modeling studies, resistance welding, friction welding, and safety and health. The 23rd International AWS Brazing and Soldering Conference wasmore » also held during this meeting. The topics presented in 24 papers included recent developments in soldering technology, brazing of stainless steel, brazing of ceramics and nickel material, filler metal developments for torch brazing, and developments in diffusion and induction brazing.« less

  1. Parametric study in weld mismatch of longitudinally welded SSME HPFTP inlet

    NASA Technical Reports Server (NTRS)

    Min, J. B.; Spanyer, K. L.; Brunair, R. M.

    1991-01-01

    Welded joints are an essential part of pressure vessels such as the Space Shuttle Main Engine (SSME) Turbopumps. Defects produced in the welding process can be detrimental to weld performance. Recently, review of the SSME high pressure fuel turbopump (HPFTP) titanium inlet x rays revealed several weld discrepancies such as penetrameter density issues, film processing discrepancies, weld width discrepancies, porosity, lack of fusion, and weld offsets. Currently, the sensitivity of welded structures to defects is of concern. From a fatigue standpoint, weld offset may have a serious effect since local yielding, in general, aggravates cyclic stress effects. Therefore, the weld offset issue is considered. Using the finite element method and mathematical formulations, parametric studies were conducted to determine the influence of weld offsets and a variation of weld widths in longitudinally welded cylindrical structures with equal wall thickness on both sides of the joint. From the study, the finite element results and theoretical solutions are presented.

  2. Long-term results of middle cerebral artery aneurysm clipping in the Barrow Ruptured Aneurysm Trial.

    PubMed

    Mooney, Michael A; Simon, Elias D; Brigeman, Scott; Nakaji, Peter; Zabramski, Joseph M; Lawton, Michael T; Spetzler, Robert F

    2018-04-27

    OBJECTIVE A direct comparison of endovascular versus microsurgical treatment of ruptured middle cerebral artery (MCA) aneurysms in randomized trials is lacking. As endovascular treatment strategies continue to evolve, the number of reports of endovascular treatment of these lesions is increasing. Herein, the authors report a detailed post hoc analysis of ruptured MCA aneurysms treated by microsurgical clipping from the Barrow Ruptured Aneurysm Trial (BRAT). METHODS The cases of patients enrolled in the BRAT who underwent microsurgical clipping for a ruptured MCA aneurysm were reviewed. Characteristics of patients and their clinical outcomes and long-term angiographic results were analyzed. RESULTS Fifty patients underwent microsurgical clipping of a ruptured MCA aneurysm in the BRAT, including 21 who crossed over from the endovascular treatment arm. Four patients with nonsaccular (e.g., dissecting, fusiform, or blister) aneurysms were excluded, leaving 46 patients for analysis. Most (n = 32; 70%) patients presented with a Hunt and Hess grade II or III subarachnoid hemorrhage, with a high prevalence of intraparenchymal blood (n = 23; 50%), intraventricular blood (n = 21; 46%), or both. At the last follow-up (up to 6 years after treatment), clinical outcomes were good (modified Rankin Scale score 0-2) in 70% (n = 19) of 27 Hunt and Hess grades I-III patients and in 36% (n = 4) of 11 Hunt and Hess grade IV or V patients. There were no instances of rebleeding after the surgical clipping of aneurysms in this series at the time of last clinical follow-up. CONCLUSIONS Microsurgical clipping of ruptured MCA aneurysms has several advantages over endovascular treatment, including durability over time. The authors report detailed outcome data of patients with ruptured MCA aneurysms who underwent microsurgical clipping as part of a prospective, randomized trial. These results should be used for comparison with future endovascular and surgical series to ensure that the best results are being achieved for patients with ruptured MCA aneurysms.

  3. Statewide Trends in Utilization and Outcomes of Endovascular Treatment of Acute Ischemic Stroke: Analysis of Minnesota Hospital Association Data (2014 and 2015).

    PubMed

    Hussein, Haitham M; Saleem, Muhammad A; Qureshi, Adnan I

    2018-03-01

    The study aims at examining the changes in endovascular procedures utilization after the publication of the clinical trials showing their benefit in patients with acute ischemic stroke (AIS). Minnesota Hospital Association database from 137 member hospitals was used to calculate the statewide utilization rates for 2 periods: prior to (calendar year 2014) and after (calendar year 2015) the publication of multiple randomized clinical trials showing the efficacy of endovascular therapy. Patients were identified using International Classification of Disease, Clinical Modification, 9th revision (ICD-9) or ICD-10 codes (ICD-10 started October 2015). Utilization rates for endovascular treatment were calculated monthly, quarterly, and annually. Of the 13,043 patients admitted with AIS, 434 patients (mean age 68.5 ± 15.5 years; 51.2% women) received endovascular treatment. The number of procedures increased from 194 in 2014 to 240 in 2015. Utilization rate was 3.4% in the first quarter of 2014, gradually declined to reach its lowest value (2.6%) the last quarter of 2014, then steadily increased to reach its peak (4%) in the last quarter of 2015. Procedures performed at comprehensive stroke centers increased from 52% of total procedures in 2014 to 57.5% in 2015, whereas those performed at primary stroke centers decreased from 22.6% to 19.5%. In 2015, fewer patients had hypertension (50.4% versus 60.3%; P = .039) and more patients had chronic kidney disease (28.3% versus 15.5%; P = .001) compared with 2014. Intracranial hemorrhage, mortality rate, and rate of home discharge were similar between the 2 years. Utilization of endovascular procedures for treatment of AIS has been rapidly influenced by medical literature. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. The impact of hybrid neurosurgeons on the outcomes of endovascular coiling for unruptured cerebral aneurysms

    PubMed Central

    Bekelis, Kimon; Gottlieb, Dan; Labropoulos, Nicos; Su, Yin; Tzoumakaris, Stavropoula; Jabbour, Pasqual; MacKenzie, Todd A.

    2017-01-01

    Background The impact of combined practices on the outcomes of unruptured cerebral aneurysm coiling remains an issue of debate. We investigated the association of combined open and endovascular expertise with the outcomes of unruptured cerebral aneurysm coiling. Methods We performed a cohort study of 100% of Medicare fee-for-service claims data for elderly patients who underwent endovascular coiling for unruptured cerebral aneurysms from 2007 to 2012. In order to control for confounding we used propensity score conditioning, with mixed effects to account for clustering at the HRR level. Results During the study period, there were 11,716 patients, who underwent endovascular coiling for unruptured cerebral aneurysms, and met the inclusion criteria. Of these, 1,186 (10.1%) underwent treatment by hybrid neurosurgeons, and 10,530 (89.9%) by proceduralists who performed only endovascular coiling. Multivariable regression analysis with propensity score adjustment demonstrated lack of association of combined practice with 1-year postoperative mortality (OR, 0.84; 95% CI, 0.58–1.23), discharge to rehabilitation (OR, 1.0; 95% CI, 0.66–1.51), 30-day readmission rate (OR, 1.07; 95% CI, 0.83–1.38) and length of stay (LOS) (adjusted difference, 0.41; 95% CI, −0.26 to 1.09). Higher procedural volume was independently associated with improved outcomes. Conclusions In a cohort of Medicare patients, we did not demonstrate a difference in mortality, discharge to rehabilitation, readmission rate, and LOS between hybrid neurosurgeons, and proceduralists only performing endovascular coiling. Funding Supported by grants from the National Institute on Aging (PO1- AG19783), the National Institutes of Health Common Fund (U01-AG046830), and the National Center for Advancing Translational Sciences (NCATS) of the NIH (Dartmouth Clinical and Translational Science Institute-UL1TR001086). The funders had no role in the design or execution of the study. PMID:26918479

  5. Computed Tomographic Perfusion Predicts Poor Outcomes in a Randomized Trial of Endovascular Therapy.

    PubMed

    Wannamaker, Robert; Guinand, Taurian; Menon, Bijoy K; Demchuk, Andrew; Goyal, Mayank; Frei, Donald; Bharatha, Aditya; Jovin, Tudor G; Shankar, Jai; Krings, Timo; Baxter, Blaise; Holmstedt, Christine; Swartz, Richard; Dowlatshahi, Dar; Chan, Richard; Tampieri, Donatella; Choe, Hana; Burns, Paul; Gentile, Nina; Rempel, Jeremy; Shuaib, Ashfaq; Buck, Brian; Bivard, Andrew; Hill, Michael; Butcher, Kenneth

    2018-06-01

    In the ESCAPE trial (Endovascular Treatment for Small Core and Anterior Circulation Proximal Occlusion with Emphasis on Minimizing CT to Recanalization Times), patients with large vessel occlusions and small infarct cores identified with computed tomography (CT)/CT angiography were randomized to endovascular therapy or standard of care. CT perfusion (CTP) was obtained in some cases but was not used to select patients. We tested the hypothesis that patients with penumbral CTP patterns have higher rates of good clinical outcome. All CTP data acquired in ESCAPE patients were analyzed centrally using a semiautomated perfusion threshold-based approach. A penumbral pattern was defined as an infarct core <70 mL, penumbral volume >15 mL, and a total hypoperfused volume:core volume ratio of >1.8. The primary outcome was good functional outcome at 90 days (modified Rankin Scale score, 0-2). CTP was acquired in 138 of 316 ESCAPE patients. Penumbral patterns were present in 116 of 128 (90.6%) of patients with interpretable CTP data. The rate of good functional outcome in penumbral pattern patients (53 of 114; 46%) was higher than that in nonpenumbral patients (2 of 12; 17%; P =0.041). In penumbral patients, endovascular therapy increased the likelihood of a good clinical outcome (34 of 58; 57%) compared with those in the control group (19 of 58; 33%; odds ratio, 2.68; 95% confidence interval, 1.25-5.76; P =0.011). Only 3 of 12 nonpenumbral patients were randomized to the endovascular group, preventing an analysis of treatment effect. The majority of patients with CTP imaging in the ESCAPE trial had penumbral patterns, which were associated with better outcomes overall. Patients with penumbra treated with endovascular therapy had the greatest odds of good functional outcome. Nonpenumbral patients were much less likely to achieve good outcomes. © 2018 American Heart Association, Inc.

  6. Kinematics effectively delineate accomplished users of endovascular robotics with a physical training model.

    PubMed

    Duran, Cassidy; Estrada, Sean; O'Malley, Marcia; Lumsden, Alan B; Bismuth, Jean

    2015-02-01

    Endovascular robotics systems, now approved for clinical use in the United States and Europe, are seeing rapid growth in interest. Determining who has sufficient expertise for safe and effective clinical use remains elusive. Our aim was to analyze performance on a robotic platform to determine what defines an expert user. During three sessions, 21 subjects with a range of endovascular expertise and endovascular robotic experience (novices <2 hours to moderate-extensive experience with >20 hours) performed four tasks on a training model. All participants completed a 2-hour training session on the robot by a certified instructor. Completion times, global rating scores, and motion metrics were collected to assess performance. Electromagnetic tracking was used to capture and to analyze catheter tip motion. Motion analysis was based on derivations of speed and position including spectral arc length and total number of submovements (inversely proportional to proficiency of motion) and duration of submovements (directly proportional to proficiency). Ninety-eight percent of competent subjects successfully completed the tasks within the given time, whereas 91% of noncompetent subjects were successful. There was no significant difference in completion times between competent and noncompetent users except for the posterior branch (151 s:105 s; P = .01). The competent users had more efficient motion as evidenced by statistically significant differences in the metrics of motion analysis. Users with >20 hours of experience performed significantly better than those newer to the system, independent of prior endovascular experience. This study demonstrates that motion-based metrics can differentiate novice from trained users of flexible robotics systems for basic endovascular tasks. Efficiency of catheter movement, consistency of performance, and learning curves may help identify users who are sufficiently trained for safe clinical use of the system. This work will help identify the learning curve and specific movements that translate to expert robotic navigation. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Contemporary economic and clinical evaluations of endovascular repair for intact descending thoracic aortic aneurysms.

    PubMed

    Silingardi, Roberto; Gennai, Stefano; Coppi, Giovanni; Chester, Johanna; Marcheselli, Luigi; Brunetti, Massimo

    2017-12-01

    The aim of this study was to assess clinical and contemporary costs associated with elective endovascular repair of intact descending thoracic aortic aneurysms (DTAA) into the mid-term follow-up. A retrospective review of a prospectively maintained clinical database including 29 consecutive patients from July 2005 to December 2009 treated with elective endovascular repair (TEVAR) or TEVAR and surgical infrarenal repair (hybrid) of intact DTAA was performed. Mean age was 74.5 years old (±7.1). Primary clinical endpoints include mortality and major morbidity. Additionally a comprehensive economic appraisal of individual in-hospital and follow-up costs was executed. Economic endpoints include in-hospital and follow-up costs and patient discharge status. Elective endovascular and open repairs' clinical and economical outcomes in contemporary literature were assessed for comparison according to PRISMA standards. Immediate mortality was 6.9% (1/24 TEVAR and 1/5 hybrid). Three respiratory complications were recorded (11%; 2 TEVAR, 1 hybrid). Renal and cardiac complication rates were 7.4% (1 TEVAR, 1 hybrid) and 3.7% (1 TEVAR) respectively. Routine discharge home was achieved for 85% of patients (95.7% TEVAR, 25% hybrid). Three endoleaks were treated throughout the follow-up (2 TEVAR, 1 hybrid; mean 30.4 mo, ±19.9) rendering an 11% (3/27) reintervention rate. Average immediate cost was €21,976.87 for elective endovascular repair and €33,783.21 for elective endovascular hybrid repair. Additional reintervention and routine follow-up costs augmented immediate costs by 12.4%. This study supports satisfying immediate clinical outcomes for TEVAR and TEVAR+surgical infrarenal procedures. Although limited by a small population size and difficulties in economic comparisons, this study presents the real world social and economic cost scenario for both elective TEVAR and TEVAR hybrid treatment of DTAA of both the in-hospital and at mid term follow-up periods.

  8. Preclinical testing for aortic endovascular grafts: results of a Food and Drug Administration workshop.

    PubMed

    Abel, Dorothy B; Beebe, Hugh G; Dedashtian, Mark M; Morton, Michael C; Moynahan, Megan; Smith, Loius J; Weinberg, Steven L

    2002-05-01

    Since their introduction into clinical trials in the United States, endovascular aortic grafts have shown various types of problems. Although details of design and construction vary between different endovascular grafts and failure modes have had a variety of causes and clinical effects, the inability of preclinical testing to predict these failures remains common to all endovascular grafts. The need to improve preclinical testing in an attempt to reduce clinical device failures resulted in a Food and Drug Administration-sponsored workshop on endovascular graft preclinical testing held in Rockville, Md, from July 31 to August 1, 2001. FORMAT: The workshop was not designed as a consensus conference. Instead, it provided a forum for bringing stakeholders together to define problems and identify areas of agreement and disagreement. The workshop had 34 invited participants who represented device manufacturers, the medical community, the Food and Drug Administration, and testing facilities, and international attendance was more than 120 people. Discussion centered on: 1, defining the physiologic, anatomic, and morphologic characteristics of abdominal aortic aneurysms before and after endovascular graft treatment; 2, identifying the types of failures that have been observed clinically; and 3, determining which characteristics should be considered during preclinical modeling to better predict clinical performance. Attendees agreed to the need to better define and address anatomic characteristics and changes in the aneurysm after endograft treatment to optimize preclinical testing. Much discussion and little agreement occurred on the importance of flow-related forces on graft performance or the need or ability to define and model physiologic compliance during durability testing. The discussion and conclusions are summarized in this paper and are provided in detail at: http://www.fda.gov/cdrh/meetings/073101workshop.html. The workshop raised awareness of significant performance issues and the challenges of modeling the extremely variable and relatively undefined environment of abdominal aortic aneurysms. Through the interactive format of the workshop, participants identified areas of preclinical testing, device design, and aspects of the simulated environment that need further consideration.

  9. Study of weld offset in longitudinally welded SSME HPFTP inlet

    NASA Technical Reports Server (NTRS)

    Min, J. B.; Spanyer, K. S.; Brunair, R. M.

    1992-01-01

    Welded joints are an essential part of rocket engine structures such as the Space Shuttle Main Engine (SSME) turbopumps. Defects produced in the welding process can be detrimental to weld performance. Recently, review of the SSME high pressure fuel turbopump (HPFTP) titanium inlet X-rays revealed several weld discrepancies such as penetrameter density issues, film processing discrepancies, weld width discrepancies, porosity, lack of fusion, and weld offsets. Currently, the sensitivity of welded structures to defects is of concern. From a fatigue standpoint, weld offset may have a serious effect since local yielding, in general, aggravates cyclic stress effects. Therefore, the weld offset issue is considered in this report. Using the FEM and beamlike plate approximations, parametric studies were conducted to determine the influence of weld offsets and a variation of weld widths in longitudinally welded cylindrical structures with equal wall thicknesses on both sides of the joint. Following the study, some conclusions are derived for the weld offsets.

  10. Weld analysis and control system

    NASA Technical Reports Server (NTRS)

    Kennedy, Larry Z. (Inventor); Rodgers, Michael H. (Inventor); Powell, Bradley W. (Inventor); Burroughs, Ivan A. (Inventor); Goode, K. Wayne (Inventor)

    1994-01-01

    The invention is a Weld Analysis and Control System developed for active weld system control through real time weld data acquisition. Closed-loop control is based on analysis of weld system parameters and weld geometry. The system is adapted for use with automated welding apparatus having a weld controller which is capable of active electronic control of all aspects of a welding operation. Enhanced graphics and data displays are provided for post-weld analysis. The system provides parameter acquisition, including seam location which is acquired for active torch cross-seam positioning. Torch stand-off is also monitored for control. Weld bead and parent surface geometrical parameters are acquired as an indication of weld quality. These parameters include mismatch, peaking, undercut, underfill, crown height, weld width, puddle diameter, and other measurable information about the weld puddle regions, such as puddle symmetry, etc. These parameters provide a basis for active control as well as post-weld quality analysis and verification. Weld system parameters, such as voltage, current and wire feed rate, are also monitored and archived for correlation with quality parameters.

  11. B218 Weld Filler Wire Characterization for Al-Li Alloy 2195

    NASA Technical Reports Server (NTRS)

    Bjorkman, Gerry; Russell, Carolyn

    2000-01-01

    NASA Marshall Space Flight Center, Lockheed Martin Space Systems- Michoud Operations, and McCook Metals have developed an aluminum-copper weld filler wire for fusion welding aluminum lithium alloy 2195. The aluminum-copper based weld filler wire has been identified as B218, a McCook Metals designation. B218 is the result of six years of weld filler wire development funded by NASA, Lockheed Martin, and McCook Metals. The filler wire chemistry was developed to produce enhanced 2195 weld and repair weld mechanical properties over the 4043 aluminum-silicon weld filler wire, which is currently used to weld 2195 on the Super Lightweight External Tank for the NASA Space Shuttle Program. An initial characterization was performed consisting of a repair weld evaluation using B218 and 4043 weld filler wires. The testing involved room temperature and cryogenic repair weld tensile testing along with fracture toughness testing. From the testing, B218 weld filler wire produce enhanced repair weld tensile strength, ductility, and fracture properties over 4043. B218 weld filler wire has proved to be a superior weld filler wire for welding aluminum lithium alloy 2195 over 4043.

  12. Effects of electrode bevel angle on argon arc properties and weld shape

    NASA Astrophysics Data System (ADS)

    Dong, W. C.; Lu, S. P.; Li, D. Z.; Y Li, Y.

    2012-07-01

    A numerical modeling of coupled welding arc with weld pool is established using FLUENT software for moving shielded GTA welding to systematically investigate the effects of electrode bevel angle on the argon arc properties as well as the weld shape on SUS304 stainless steel. The calculated results show that the argon arc is constricted and the peak values of heat flux and shear stress on the weld pool decrease with increasing electrode bevel angle, while the radial distribution of heat flux and shear stress varying slightly. The weld shape is controlled by the pool flow patterns driving by the surface tension, gas shear stress, electromagnetic force and buoyancy. The Marangoni convection induced by surface tension plays an important role on weld shapes. All the weld shapes are wide and shallow with low weld metal oxygen content, while the narrow and deep weld shapes form under high weld metal oxygen content, which is related with the oxygen concentration in the shielding gas. The weld depth/width (D/W) ratio increases with increasing electrode bevel angle for high weld metal oxygen content and is not sensitive to the electrode bevel angle under low weld metal oxygen content. The calculated results for the weld shape, weld size and weld D/W ratio agree well with the experimental ones.

  13. Effect of Welding Processes on the Microstructure, Mechanical Properties and Residual Stresses of Plain 9Cr-1Mo Steel Weld Joints

    NASA Astrophysics Data System (ADS)

    Nagaraju, S.; Vasantharaja, P.; Brahadees, G.; Vasudevan, M.; Mahadevan, S.

    2017-12-01

    9Cr-1Mo steel designated as P9 is widely used in the construction of power plants and high-temperature applications. It is chosen for fabricating hexcan fuel subassembly wrapper components of fast breeder reactors. Arc welding processes are generally used for fabricating 9Cr-1Mo steel weld joints. A-TIG welding process is increasingly being adopted by the industries. In the present study, shielded metal arc (SMA), tungsten inert gas (TIG) and A-TIG welding processes are used for fabricating the 9Cr-1Mo steel weld joints of 10 mm thickness. Effect of the above welding processes on the microstructure evolution, mechanical properties and residual stresses of the weld joints has been studied in detail. All the three weld joints exhibited comparable strength and ductility values. 9Cr-1Mo steel weld joint fabricated by SMAW process exhibited lower impact toughness values caused by coarser grain size and inclusions. 9Cr-1Mo steel weld joint fabricated by TIG welding exhibited higher toughness due to finer grain size, while the weld joint fabricated by A-TIG welding process exhibited adequate toughness values. SMA steel weld joint exhibited compressive residual stresses in the weld metal and HAZ, while TIG and A-TIG weld joint exhibited tensile residual stresses in the weld metal and HAZ.

  14. Hybrid Endovascular Aortic Aneurysm Repair: Preservation of Pelvic Perfusion with External to Internal Iliac Artery Bypass.

    PubMed

    Mansukhani, Neel A; Havelka, George E; Helenowski, Irene B; Rodriguez, Heron E; Hoel, Andrew W; Eskandari, Mark K

    2017-07-01

    Diminished pelvic arterial flow as a result of intentional coverage/embolization of internal iliac arteries (IIA) during isolated endovascular common iliac artery aneurysm (CIAA) repair or endovascular repair of abdominal aortic aneurysms (EVAR) may result in symptomatic pelvic ischemia. Although generally well tolerated, in severe cases, pelvic ischemia may manifest as recalcitrant buttock claudication, vasculogenic impotence, or perineal, vesicle, rectal, and/or spinal cord ischemia. Branched graft technology has recently become available; however, many patients are not candidates for endovascular repair with these devices. Therefore, techniques to preserve pelvic arterial flow are needed. We reviewed our outcomes of isolated endovascular CIAA repair or EVAR in conjunction with unilateral external-internal iliac artery bypass. Single-center, retrospective review of 10 consecutive patients who underwent hybrid endovascular abdominal aortic aneurysm (AAA) or CIAA repair with concomitant external-internal iliac artery bypass between 2006 and 2015. Demographics, index procedural details, postoperative symptoms, hospital length of stay (LOS), follow-up imaging, and bypass patency were recorded. The cohort of 10 patients was all men with a mean age of 71 years (range: 56-84). Hybrid repair consisted of contralateral IIA coil embolization followed by EVAR with external iliac artery-internal iliac artery (EIA-IIA) bypass. All EIA-IIA bypasses were performed via a standard lower quadrant retroperitoneal approach with a prosthetic bypass graft. Technical success was 100%, and there were no perioperative deaths. One patient developed transient paraplegia, 1 patient had buttock claudication on the side of his hypogastric embolization contralateral to his iliac bypass, and 1 developed postoperative impotence. 20% of patients sustained long-term complications (buttock claudication and postoperative impotence). Mean LOS was 2.8 days (range: 1-9 days). Postoperative imaging was obtained in 90% of patients, and mean follow-up was 10.8 months (range: 0.5-36 months). All bypasses remained patent. Although branched graft technology continues to evolve, strategies to maintain adequate pelvic circulation are necessary to avoid the devastating complications of pelvic ischemia. We have demonstrated that a hybrid approach combining EVAR or isolated endovascular common iliac artery exclusion with a unilateral external-internal iliac bypass via a retroperitoneal approach is well tolerated with a short LOS and excellent patency rates. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. An Approach to Maximize Weld Penetration During TIG Welding of P91 Steel Plates by Utilizing Image Processing and Taguchi Orthogonal Array

    NASA Astrophysics Data System (ADS)

    Singh, Akhilesh Kumar; Debnath, Tapas; Dey, Vidyut; Rai, Ram Naresh

    2017-10-01

    P-91 is modified 9Cr-1Mo steel. Fabricated structures and components of P-91 has a lot of application in power and chemical industry owing to its excellent properties like high temperature stress corrosion resistance, less susceptibility to thermal fatigue at high operating temperatures. The weld quality and surface finish of fabricated structure of P91 is very good when welded by Tungsten Inert Gas welding (TIG). However, the process has its limitation regarding weld penetration. The success of a welding process lies in fabricating with such a combination of parameters that gives maximum weld penetration and minimum weld width. To carry out an investigation on the effect of the autogenous TIG welding parameters on weld penetration and weld width, bead-on-plate welds were carried on P91 plates of thickness 6 mm in accordance to a Taguchi L9 design. Welding current, welding speed and gas flow rate were the three control variables in the investigation. After autogenous (TIG) welding, the dimension of the weld width, weld penetration and weld area were successfully measured by an image analysis technique developed for the study. The maximum error for the measured dimensions of the weld width, penetration and area with the developed image analysis technique was only 2 % compared to the measurements of Leica-Q-Win-V3 software installed in optical microscope. The measurements with the developed software, unlike the measurements under a microscope, required least human intervention. An Analysis of Variance (ANOVA) confirms the significance of the selected parameters. Thereafter, Taguchi's method was successfully used to trade-off between maximum penetration and minimum weld width while keeping the weld area at a minimum.

  16. Effect of Activated Flux on the Microstructure, Mechanical Properties, and Residual Stresses of Modified 9Cr-1Mo Steel Weld Joints

    NASA Astrophysics Data System (ADS)

    Maduraimuthu, V.; Vasudevan, M.; Muthupandi, V.; Bhaduri, A. K.; Jayakumar, T.

    2012-02-01

    A novel variant of tungsten inert gas (TIG) welding called activated-TIG (A-TIG) welding, which uses a thin layer of activated flux coating applied on the joint area prior to welding, is known to enhance the depth of penetration during autogenous TIG welding and overcomes the limitation associated with TIG welding of modified 9Cr-1Mo steels. Therefore, it is necessary to develop a specific activated flux for enhancing the depth of penetration during autogeneous TIG welding of modified 9Cr-1Mo steel. In the current work, activated flux composition is optimized to achieve 6 mm depth of penetration in single-pass TIG welding at minimum heat input possible. Then square butt weld joints are made for 6-mm-thick and 10-mm-thick plates using the optimized flux. The effect of flux on the microstructure, mechanical properties, and residual stresses of the A-TIG weld joint is studied by comparing it with that of the weld joints made by conventional multipass TIG welding process using matching filler wire. Welded microstructure in the A-TIG weld joint is coarser because of the higher peak temperature in A-TIG welding process compared with that of multipass TIG weld joint made by a conventional TIG welding process. Transverse strength properties of the modified 9Cr-1Mo steel weld produced by A-TIG welding exceeded the minimum specified strength values of the base materials. The average toughness values of A-TIG weld joints are lower compared with that of the base metal and multipass weld joints due to the presence of δ-ferrite and inclusions in the weld metal caused by the flux. Compressive residual stresses are observed in the fusion zone of A-TIG weld joint, whereas tensile residual stresses are observed in the multipass TIG weld joint.

  17. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    PubMed

    Ederle, Jörg; Bonati, Leo H; Dobson, Joanna; Featherstone, Roland L; Gaines, Peter A; Beard, Jonathan D; Venables, Graham S; Markus, Hugh S; Clifton, Andrew; Sandercock, Peter; Brown, Martin M

    2009-10-01

    Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS). Between March, 1992, and July, 1997, patients who presented at a participating centre with a confirmed stenosis of the internal carotid artery that was deemed equally suitable for either carotid endarterectomy or endovascular treatment were randomly assigned to either treatment in equal proportions by telephone or fax from the randomisation service at the Oxford Clinical Trials Unit, UK. Patients were seen by an independent neurologist at 1 and 6 months after treatment and then every year after randomisation for as long as possible, up to a maximum of 11 years. Major outcome events were transient ischaemic attack, non-disabling, disabling, and fatal stroke, myocardial infarction, and death from any other cause. Outcomes were adjudicated on by investigators who were masked to treatment. Analysis was by intention to treat. This study is registered, number ISRCTN 01425573. 504 patients with stenosis of the carotid artery (90% symptomatic) were randomly assigned to endovascular treatment (n=251) or surgery (n=253). Within 30 days of treatment, there were more minor strokes that lasted less than 7 days in the endovascular group (8 vs 1) but the number of other strokes in any territory or death was the same (25 vs 25). There were more cranial nerve palsies (22 vs 0) in the endarterectomy group than in the endovascular group. Median length of follow up in both groups was 5 years (IQR 2-6). By comparing endovascular treatment with endarterectomy after the 30-day post-treatment period, the 8-year incidence and hazard ratio (HR) at the end of follow-up for ipsilateral non-perioperative stroke was 11.3% versus 8.6% (HR 1.22, 95% CI 0.59-2.54); for ipsilateral non-perioperative stroke or TIA was 19.3% versus 17.2% (1.29, 0.78-2.14); and for any non-perioperative stroke was 21.1% versus 15.4% (1.66, 0.99-2.80). More patients had stroke during follow-up in the endovascular group than in the surgical group, but the rate of ipsilateral non-perioperative stroke was low in both groups and none of the differences in the stroke outcome measures was significant. However, the study was underpowered and the confidence intervals were wide. More long-term data are needed from the on going stenting versus endarterectomy trials. British Heart Foundation; UK National Health Service Management Executive; UK Stroke Association.

  18. A systematic review of primary endovascular repair of the ascending aorta.

    PubMed

    Muetterties, Corbin E; Menon, Rohan; Wheatley, Grayson H

    2018-01-01

    Endovascular repair of the ascending aorta is currently limited to patients at high surgical risk with aortic diseases originating above the sinotubular junction. A number of different endovascular technologies and approaches have been used, although no consensus exists regarding a standardized technique. To better understand real-world endovascular approaches to the ascending aorta, we performed a comprehensive review of the types of endovascular aortic stents and associated vascular access used in repair of the ascending aorta. A search of the MEDLINE database was conducted from January 1, 1995, through January 31, 2017, with the search term "ascending aortic stent." Studies involving endovascular stenting in which the primary therapy was confined exclusively to the ascending aorta were included. Studies involving hybrid arch procedures and surgical replacement of the ascending aorta associated with aortic stenting were excluded. The type of aortic stent, underlying aortic disease, and surgical approach were recorded along with outcomes, need for reinterventions, and follow-up. A total of 46 publications that focused on primary endovascular repair of the ascending aorta were identified. Thirteen different aortic stent grafts of various designs were used in 118 total patients. The most commonly used device types were thoracic stents (n = 84 [71.2%]) along with abdominal cuffs (n = 13 [11%]) and custom-made grafts (n = 12 [10.2%]). The most commonly treated aortic disease was type A aortic dissection (n = 59 [50%]), followed by aortic pseudoaneurysm (n = 35 [29.7%]), aortic aneurysm (n = 6 [5.1%]), penetrating atherosclerotic ulcer (n = 5 [4.2%]), and acute aortic rupture (n = 3 [2.5%]). Femoral arterial access was used in 62.7% of patients (n = 74); transapical (n = 17 [14.4%]), carotid (n = 15 [12.7%]), and axillary (n = 8 [6.8%]) approaches were also used. The overall type I endoleak rate was 18.6% (n = 22), with 11 patients (9.3%) requiring reintervention. Other complications included all-cause mortality (n = 18 [15.2%]), conversions to open surgery (n = 4 [3.4%]), and cerebrovascular complications (n = 4 [3.4%]). Aorta-related mortality was 5% (n = 6), and average follow-up was 17.2 months. Despite the absence of a dedicated aortic stent graft for the ascending aorta, patients with a range of ascending aortic diseases are being successfully treated by endovascular technologies. For optimal outcomes, patient selection is critical to align aortic anatomy with the limited device sizing options, and it should be reserved for patients at high surgical risk. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  19. The 25th anniversary of the retrograde suction decompression technique (Dallas technique) for the surgical management of paraclinoid aneurysms: historical background, systematic review, and pooled analysis of the literature.

    PubMed

    Flores, Bruno C; White, Jonathan A; Batjer, H Hunt; Samson, Duke S

    2018-05-04

    OBJECTIVE Paraclinoid internal carotid artery (ICA) aneurysms frequently require temporary occlusion to facilitate safe clipping. Brisk retrograde flow through the ophthalmic artery and cavernous ICA branches make simple trapping inadequate to soften the aneurysm. The retrograde suction decompression (RSD), or Dallas RSD, technique was described in 1990 in an attempt to overcome some of those treatment limitations. A frequent criticism of the RSD technique is an allegedly high risk of cervical ICA dissection. An endovascular modification was introduced in 1991 (endovascular RSD) but no studies have compared the 2 RSD variations. METHODS The authors performed a systematic review of MEDLINE/PubMed and Web of Science and identified all studies from 1990-2016 in which either Dallas RSD or endovascular RSD was used for treatment of paraclinoid aneurysms. A pooled analysis of the data was completed to identify important demographic and treatment-specific variables. The primary outcome measure was defined as successful aneurysm obliteration. Secondary outcome variables were divided into overall and RSD-specific morbidity and mortality rates. RESULTS Twenty-six RSD studies met the inclusion criteria (525 patients, 78.9% female). The mean patient age was 53.5 years. Most aneurysms were unruptured (56.6%) and giant (49%). The most common presentations were subarachnoid hemorrhage (43.6%) and vision changes (25.3%). The aneurysm obliteration rate was 95%. The mean temporary occlusion time was 12.7 minutes. Transient or permanent morbidity was seen in 19.9% of the patients. The RSD-specific complication rate was low (1.3%). The overall mortality rate was 4.2%, with 2 deaths (0.4%) attributable to the RSD technique itself. Good or fair outcome were reported in 90.7% of the patients. Aneurysm obliteration rates were similar in the 2 subgroups (Dallas RSD 94.3%, endovascular RSD 96.3%, p = 0.33). Despite a higher frequency of complex (giant or ruptured) aneurysms, Dallas RSD was associated with lower RSD-related morbidity (0.6% vs 2.9%, p = 0.03), compared with the endovascular RSD subgroup. There was a trend toward higher mortality in the endovascular RSD subgroup (6.4% vs 3.1%, p = 0.08). The proportion of patients with poor neurological outcome at last follow-up was significantly higher in the endovascular RSD group (15.4% vs 7.2%, p < 0.01). CONCLUSIONS The treatment of paraclinoid ICA aneurysms using the RSD technique is associated with high aneurysm obliteration rates, good long-term neurological outcome, and low RSD-related morbidity and mortality. Review of the RSD literature showed no evidence of a higher complication rate associated with the Dallas technique compared with similar endovascular methods. On a subgroup analysis of Dallas RSD and endovascular RSD, both groups achieved similar obliteration rates, but a lower RSD-related morbidity was seen in the Dallas technique subgroup. Twenty-five years after its initial publication, RSD remains a useful neurosurgical technique for the management of large and giant paraclinoid aneurysms.

  20. Spot-Welding Gun Is Easy To Use

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E.; Nguyen, Francis H.

    1991-01-01

    Electrical-resistance spot-welding gun designed to produce more welds per unit time by decreasing technician's effort and fatigue. Vacuum cups on frame secure welding gun to workpiece while compressed air drives welding tip against workpiece to make spot resistance weld. When weld completed, vacuum in frame cups released so frame and gun moved to position of next spot weld.

  1. Characterizing Shipyard Welding Emissions and Associated Control Options (The National Shipbuilding Research Program)

    DTIC Science & Technology

    1995-08-01

    TRl) Occupational Health and Safety Administration (OSHA) Air Quality Legislation Hexavalent Chromium and the Legislation List-of-list Chemicals and...2.2.7 2.2.8 Shielded Metal Arc Welding (SMAW) Submerged Arc Welding (SAW) Gas Metal Arc Welding (GMAW) Gas Tungsten Arc Welding ( GTAW ) Flux Core Arc... GTAW Welding Processes Advantages and Disadvantages of FCAW Welding Processes Welding Process Comparison Matrix Diagram of SMAW Welding Process

  2. Effects of Fusion Tack Welds on Self-Reacting Friction Stir Welds

    NASA Technical Reports Server (NTRS)

    Nunes, A. C., Jr.; Pendleton, M. L.; Brooke, S. A.; Russell, C. K.

    2012-01-01

    In order to know whether fusion tack welds would affect the strength of self-reacting friction stir seam welds in 2195-T87 aluminum alloy, the fracture stresses of 144 tensile test coupons cut from 24 welded panels containing segments of friction stir welds were measured. Each of the panels was welded under unique processing conditions. A measure of the effect of the tack welds for each panel was devised. An analysis of the measures of the tack weld effect supported the hypothesis that fusion tack welds do not affect the strength of self-reacting friction stir welds to a 5% level of confidence.

  3. Research on the Effect of Welding Speed on the Quality of Welding Seam Based on the Local Dry Underwater Welding

    NASA Astrophysics Data System (ADS)

    Liu, Lei; Chen, Wu; Wang, Huagang; Ba, Jinyu; Li, Bing

    2017-12-01

    The repair of nuclear spent fuel pool has a high requirement for the quality of welding, the welding speed directly affects the quality of the weld when local dry automatic underwater welding is used to repair the damaged surface. Under the condition of the same condition, the local dry automatic underwater welding test was carried out under the condition of the same welding condition. Taking the 20cm as the experimental condition, after massive experiments show that when the welding speed is approximately 48cm/min the weld quality is high, meeting the design requirements, based on the double layer shrinkage nozzle chamber of local dry underwater automatic welding.

  4. High-velocity frictional properties of gabbro

    NASA Astrophysics Data System (ADS)

    Tsutsumi, Akito; Shimamoto, Toshihiko

    High-velocity friction experiments have been performed on a pair of hollow-cylindrical specimens of gabbro initially at room temperature, at slip rates from 7.5 mm/s to 1.8 m/s, with total circumferential displacements of 125 to 174 m, and at normal stresses to 5 MPa, using a rotary-shear high-speed friction testing machine. Steady-state friction increases slightly with increasing slip rate at slip rates to about 100 mm/s (velocity strengthening) and it decreases markedly with increasing slip rate at higher velocities (velocity weakening). Steady-state friction in the velocity weakening regime is lower for the non-melting case than the frictional melting case, due perhaps to severe thermal fracturing. A very large peak friction is always recognized upon the initiation of visible frictional melting, presumably owing to the welding of fault surfaces upon the solidification of melt patches. Frictional properties thus change dramatically with increasing displacement at high velocities, and such a non-linear effect must be incorporated into the analysis of earthquake initiation processes.

  5. Effect of welding position on porosity formation in aluminum alloy welds

    NASA Technical Reports Server (NTRS)

    Haryung, J.; Wroth, R. S.

    1967-01-01

    Program investigates the effects of varied welding positions on weld qualities. Progressive changes in bead geometry occur as the weld plane angle is varied from upslope to downslope. The gravitational effect on the weld puddle varies greatly with welding position.

  6. Latest MIG, TIG arc-YAG laser hybrid welding systems for various welding products

    NASA Astrophysics Data System (ADS)

    Ishide, Takashi; Tsubota, Shuho; Watanabe, Masao

    2003-03-01

    Laser welding is capable of high-efficiency low-strain welding, and so its applications are started to various products. We have also put the high-power YAG laser of up to 10 kW to practical welding use for various products. On the other hand the weakest point of this laser welding is considered to be strict in the welding gap aiming allowance. In order to solve this problem, we have developed hybrid welding of TIG, MIG arc and YAG laser, taking the most advantages of both the laser and arc welding. Since the electrode is coaxial to the optical axis of the YAG laser in this process, it can be applied to welding of various objects. In the coaxial MIG, TIG-YAG welding, in order to make irradiation positions of the YAG laser beams having been guided in a wire or an electrode focused to the same position, the beam transmitted in fibers is separated to form a space between the separated beams, in which the laser is guided. With this method the beam-irradiating area can be brought near or to the arc-generating point. This enables welding of all directions even for the member of a three-dimensional shape. This time we carried out welding for various materials and have made their welding of up to 1 mm or more in welding groove gap possible. We have realized high-speed 1-pass butt welding of 4m/min in welding speed with the laser power of 3 kW for an aluminum alloy plate of approximately 4 mm thick. For a mild steel plate also we have realized butt welding of 1m/min with 5 kW for 6 mm thick. Further, in welding of stainless steel we have shown its welding possibility, by stabilizing the arc with the YAG laser in the welding atmosphere of pure argon, and shown that this welding is effective in high-efficiency welding of various materials. Here we will report the fundamental welding performances and applications to various objects for the coaxial MIG, TIG-YAG welding we have developed.

  7. Gravitational effects on the weld pool shape and microstructural evolution during gas tungsten arc and laser beam welding of 304 stainless steel and Al-4 wt% Cu alloy.

    PubMed

    Kang, Namhyun; Singh, Jogender; Kulkarni, Anil K

    2004-11-01

    Effects of gravitational acceleration were investigated on the weld pool shape and microstructural evolution for 304 stainless steel and Al-4wt% Cu alloy. Effects of welding heat source were investigated by using laser beam welding (LBW) and gas tungsten arc welding (GTAW). As the gravitational level was increased from low gravity (LG approximately 1.2 g) to high gravity (HG approximately 1.8 g) using a NASA KC-135 aircraft, the weld pool shape for 304 stainless steel was influenced considerably during GTAW. However, insignificant change in the microstructure and solute distribution was observed at gravitational levels between LG and HG. The GTAW on Al-4 wt% Cu alloy was used to investigate the effect of gravitational orientation on the weld solidification behavior. Gravitational orientation was manipulated by varying the welding direction with respect to gravity vector; that is, by welding upward opposing gravity ( ||-U) and downward with gravity ( ||-D) on a vertical weld piece and welding perpendicular to gravity (perpendicular) on a horizontal weld piece. Under the same welding conditions, a larger primary dendrite spacing in the ||-U weld was observed near the weld pool surface and the fusion boundary than in the case of perpendicular or ||-D welds. The ||-D weld exhibited different solidification morphology and abnormal S shape of solidification rate curve during its growth. For 304 stainless steel GTAW, significant effects of gravitational orientation were observed on the weld pool shape that was associated with weld surface morphology and convection flow. However, the weld pool shape for LBW was mostly constant with respect to the gravitational orientation.

  8. Research on the microstructure and properties of laser-MIG hybrid welded joint of Invar alloy

    NASA Astrophysics Data System (ADS)

    Zhan, Xiaohong; Zhang, Dan; Wei, Yanhong; Wang, Yuhua

    2017-12-01

    In order to solve the problem of large deformation, low production efficiency and high tendency of hot cracking in welding 19.05 mm thick plates of Fe36Ni Invar alloy, laser-MIG hybrid multi-layer welding technique (LMHMW) has been developed. To investigate the influence of different welding parameters on the joint properties, optical microscope observation, SEM, EDS and microhardness measurement were conducted. Experimental results illustrated that different matching of welding parameters significantly affected the depth-to-width ratio, formation of defects and HAZ width. Besides, weld zone were consisted of two regions according to the different grain shape. The region near center of weld seam (region 1) was columnar dendrite induced by laser, while the region far away from weld seam center (region 2) was cellular dendrite which was mainly caused by MIG arc. The peak value of microhardness appeared at the center of weld seam since the grains in region 1 were relatively fine, and the lowest hardness value was obtained in HAZ. In addition, results showed that the sheets can be welded at optimum process parameters, with few defects such as, surface oxidation, porosity, cracks and lack of penetration in the welding seam: laser power of backing weld P = 5500 W, welding current I = 240 A, welding speed v = 1 m/min. laser power of filling weld P = 2000 W, welding current I = 220 A, welding speed v = 0.35 m/min. laser power of cosmetic weld P = 2000 W, welding current I = 300 A, welding speed v = 0.35 m/min.

  9. Damage Tolerance Assessment of Friction Pull Plug Welds

    NASA Technical Reports Server (NTRS)

    McGill, Preston; Burkholder, Jonathan

    2012-01-01

    Friction stir welding is a solid state welding process developed and patented by The Welding Institute in Cambridge, England. Friction stir welding has been implemented in the aerospace industry in the fabrication of longitudinal welds in pressurized cryogenic propellant tanks. As the industry looks to implement friction stir welding in circumferential welds in pressurized cryogenic propellant tanks, techniques to close out the termination hole associated with retracting the pin tool are being evaluated. Friction pull plug welding is under development as a one means of closing out the termination hole. A friction pull plug weld placed in a friction stir weld results in a non-homogenous weld joint where the initial weld, plug weld, their respective heat affected zones and the base metal all interact. The welded joint is a composite, plastically deformed material system with a complex residual stress field. In order to address damage tolerance concerns associated with friction plug welds in safety critical structures, such as propellant tanks, nondestructive inspection and proof testing may be required to screen hardware for mission critical defects. The efficacy of the nondestructive evaluation or the proof test is based on an assessment of the critical flaw size in the test or service environments. Test data relating residual strength capability to flaw size in two aluminum alloy friction plug weld configurations is presented.

  10. Automated Welding System

    NASA Technical Reports Server (NTRS)

    Bayless, E. O.; Lawless, K. G.; Kurgan, C.; Nunes, A. C.; Graham, B. F.; Hoffman, D.; Jones, C. S.; Shepard, R.

    1993-01-01

    Fully automated variable-polarity plasma arc VPPA welding system developed at Marshall Space Flight Center. System eliminates defects caused by human error. Integrates many sensors with mathematical model of the weld and computer-controlled welding equipment. Sensors provide real-time information on geometry of weld bead, location of weld joint, and wire-feed entry. Mathematical model relates geometry of weld to critical parameters of welding process.

  11. Influence of Welding Process and Post Weld Heat Treatment on Microstructure and Pitting Corrosion Behavior of Dissimilar Aluminium Alloy Welds

    NASA Astrophysics Data System (ADS)

    Venkata Ramana, V. S. N.; Mohammed, Raffi; Madhusudhan Reddy, G.; Srinivasa Rao, K.

    2018-03-01

    Welding of dissimilar Aluminum alloy welds is becoming important in aerospace, shipbuilding and defence applications. In the present work, an attempt has been made to weld dissimilar aluminium alloys using conventional gas tungsten arc welding (GTAW) and friction stir welding (FSW) processes. An attempt was also made to study the effect of post weld heat treatment (T4 condition) on microstructure and pitting corrosion behaviour of these welds. Results of the present investigation established the differences in microstructures of the base metals in T4 condition and in annealed conditions. It is evident that the thickness of the PMZ is relatively more on AA2014 side than that of AA6061 side. In FS welds, lamellar like shear bands are well noticed on the top of the stir zone. The concentration profile of dissimilar friction stir weld in T4 condition revealed that no diffusion has taken place at the interface. Poor Hardness is observed in all regions of FS welds compared to that of GTA welds. Pitting corrosion resistance of the dissimilar FS welds in all regions was improved by post weld heat treatment.

  12. Influence of Oxides on Microstructures and Mechanical Properties of High-Strength Steel Weld Joint

    NASA Astrophysics Data System (ADS)

    Cai, Yangchuan; Luo, Zhen; Huang, Zunyue; Zeng, Yida

    2016-11-01

    A comprehensive investigation was conducted into the effect of oxides on penetrations, microstructures and mechanical properties of BS700MC super steel weld bead. Boron oxide changed the penetration of weld bead by changing the Marangoni convection in the weld pool and contracting the welding arc. Chromium oxide only changed the Marangoni convection in the weld pool to increase the penetration of super steel. Thus, the super steel weld bead has higher penetration coated with flux boron oxide than that coated with chromium oxide. In other words, the activating flux TIG (A-TIG) welding with flux boron oxide has less welding heat input than the A-TIG welding with flux chromium oxide. As a result, on the one hand, there existed more fine and homogeneous acicular ferrites in the microstructure of welding heat-affected zone when the super steel was welded by A-TIG with flux boron oxide. Thus, the weld beads have higher value of low-temperature impact toughness. On the other hand, the softening degree of welding heat-affected zone, welded by A-TIG with flux boron oxide, will be decreased for the minimum value of welding heat input.

  13. Endovascular Stent Graft Placement in the Treatment of Ruptured Tuberculous Pseudoaneurysm of the Descending Thoracic Aorta: Case Report and Review of the Literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dogan, Sozen, E-mail: sozendogan@hotmail.com; Memis, Ahmet, E-mail: ahmemis@yahoo.co; Kale, Arzum, E-mail: arzumkale@kenthospital.com

    We report a successful repair of a ruptured tuberculous pseudoaneurysm of the descending thoracic aorta by endovascular stent graft placement. This procedure is starting to be accepted as an alternative method to surgery, and we review similar cases in the literature.

  14. Colonic Ischemia After Standard Endovascular Abdominal Aortic Aneurysm Repair, A Rare But Dangerous Complication.

    PubMed

    Berchiolli, R; Adami, D; Marconi, M; Mari, M; Puta, B; Ferrari, M

    2018-05-21

    Colonic Ischemia (CI) after abdominal aortic aneurysm (AAA) repair, although rare, is associated with severe prognosis. Endovascular Aneurysm Repair (EVAR) is becoming the standard of practice in most vascular centers, and it also may reduce CI incidence in comparison to conventional open repair. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prabhudesai, V., E-mail: v_prabhudesai@hotmail.com; Mitra, K.; West, D. J.

    2003-09-15

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome.

  16. Endovascular Treatment for Fusiform Dilation of Internal Carotid Artery Following Craniopharyngioma Resection: A Case Illustration.

    PubMed

    Li, Qiang; Wang, Chaohua; Xu, Jianguo; You, Chao

    2015-09-01

    Fusiform dilation of the internal carotid artery complicates aggressive craniopharyngioma resection and occurs mainly in children. We report a case to describe the availability of endovascular treatment for this rare entity. A 13-year-old boy presented with headache for 2 years after resection of craniopharyngioma. A fusiform dilation of the right carotid artery was found and was coiled using stent-assisted technique. Follow-up showed satisfactory outcome and disappearance of headache. To our knowledge, this is the first report regarding endovascular treatment for fusiform dilation of the internal carotid artery after craniopharyngioma resection. Stent-assisted coiling is a useful approach for fusiform dilation of the internal carotid artery following craniopharyngioma surgery. © The Author(s) 2014.

  17. Endovascular Management of Extra-cranial Supra-aortic Vascular Injuries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almazedi, Bahir, E-mail: b.almazedi@doctors.org.uk; Lyall, Harpreet; Bhatnagar, Priya

    Supra-aortic vessel injuries are uncommon but can be life-threatening and surgically challenging. Trauma to these vessels may be blunt or penetrating, including iatrogenic trauma following the insertion of central venous lines, which may be preventable. Recent advances in technology have resulted in endovascular therapy becoming a common first-line treatment, and interventional radiologists now play a major role in the management of these vascular injuries. We review the literature on the endovascular management of these types of injuries and describe a spectrum of case-based extra-cranial supra-aortic vascular injuries managed at our institution and the range of imaging appearances, including active contrast extravasation,more » traumatic vessel occlusion, true aneurysms, pseudoaneurysms, and arteriovenous fistulae.« less

  18. Endovascular Treatment of an Aneurysmal Aberrant Systemic Artery Supplying a Pulmonary Sequestrum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kristensen, Katrine Lawaetz, E-mail: klk@dadlnet.dk; Duus, Louise Aarup, E-mail: louise.brodersen@gmail.com; Elle, Bo, E-mail: Bo.Elle@rsyd.dk

    An aberrant systemic artery originating from the abdominal aorta supplying a pulmonary sequestration is a rare congenital malformation. This causes a left-to-left shunt. Symptoms include recurrent pneumonias, hemoptysis, and, in the long term, heart failure. Aneurysm of the aberrant vessel is rarely seen. Traditionally, treatment of pulmonary sequestrations includes ligation of the feeding vessel and lobectomy. A new promising treatment is an endovascular approach. Only a few cases describe endovascular treatment of pulmonary sequestration. This is the first published case of a giant aneurysmal branch from the abdominal aorta to the normal basal segments of the lung, successfully occluded withmore » an Amplatzer Vascular Plug II (AVP II, St.Jude Medical, MN, USA) alone.« less

  19. Congenital Intrahepatic Portosystemic Venous Shunt and Liver Mass in a Child Patient: Successful Endovascular Treatment with an Amplatzer Vascular Plug (AVP)

    PubMed Central

    Lee, Sae Ah; Lee, Young Seok; Lee, Kun Song

    2010-01-01

    A congenital intrahepatic portosystemic shunt is a rare anomaly; but, the number of diagnosed cases has increased with advanced imaging tools. Symptomatic portosystemic shunts, especially those that include hyperammonemia, should be treated; and various endovascular treatment methods other than surgery have been reported. Hepatic masses with either an intra- or extrahepatic shunt also have been reported, and the mass is another reason for treatment. Authors report a case of a congenital intrahepatic portosystemic shunt with a hepatic mass that was successfully treated using a percutaneous endovascular approach with vascular plugs. By the time the first short-term follow-up was conducted, the hepatic mass had disappeared. PMID:20808706

  20. Endovascular Interventions for Acute and Chronic Lower Extremity Deep Venous Disease: State of the Art

    PubMed Central

    Sista, Akhilesh K.; Vedantham, Suresh; Kaufman, John A.

    2015-01-01

    The societal and individual burden caused by acute and chronic lower extremity venous disease is considerable. In the past several decades, minimally invasive endovascular interventions have been developed to reduce thrombus burden in the setting of acute deep venous thrombosis to prevent both short- and long-term morbidity and to recanalize chronically occluded or stenosed postthrombotic or nonthrombotic veins in symptomatic patients. This state-of-the-art review provides an overview of the techniques and challenges, rationale, patient selection criteria, complications, postinterventional care, and outcomes data for endovascular intervention in the setting of acute and chronic lower extremity deep venous disease. Online supplemental material is available for this article. © RSNA, 2015 PMID:26101920

  1. Endovascular Repair of a Ruptured Mycotic Aneurysm of the Common Iliac Artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mofidi, R., E-mail: rmofidi@doctors.net.uk; Bhat, R.; Nagy, J.

    2007-09-15

    This report describes the case of a ruptured mycotic aneurysm of the left common iliac artery, successfully treated with endovascular stent-grafting. A 64-year-old woman underwent diagnostic coronary angiography complicated by an infected hematoma of the left groin. Seven days later, she developed methicillin-resistant Staphylococcus aureus septicemia and CT scan evidence of perivascular inflammation around the left common iliac artery. This was followed by rupture of a mycotic aneurysm of the left common iliac artery. The lesion was successfully treated with a stent-graft and prolonged antibiotic therapy, and the patient remains free of infection 10 months later. Accumulating evidence suggests thatmore » endovascular repair can be used safely for the repair of ruptured infected aneurysms.« less

  2. Minimally invasive retrieval of a dislodged Wallstent endoprosthesis after an endovascular abdominal aortic aneurysm repair.

    PubMed

    Lam, Russell C; Rhee, Soo J; Morrissey, Nicholas J; McKinsey, James F; Faries, Peter L; Kent, K Craig

    2008-02-01

    Endovascular abdominal aortic aneurysm repair (EVAR) is being performed more frequently in patients with concomitant iliac artery occlusive disease. We report a case of a 70-year-old male status post angioplasty and stenting of bilateral iliac arteries for occlusive disease who subsequently underwent EVAR for a rapidly expanding abdominal aortic aneurysm (AAA). One month after the placement of the endograft, it was discovered that the previously placed Wallstent had been dislodged during the endovascular abdominal aortic aneurysm repair. Minimally invasive retrieval using an Amplatz Goose Neck Snare was successful in recovering the stent. This case underscores the danger of performing EVAR in the setting of prior iliac artery stenting and the potential complications that may ensue.

  3. ChEVAS: Combining Suprarenal EVAS with Chimney Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torella, Francesco, E-mail: f.torella@liverpool.ac.uk; Chan, Tze Y., E-mail: tze.chan@rlbuht.nhs.uk; Shaikh, Usman, E-mail: usman.shaikh@rlbuht.nhs.uk

    2015-10-15

    Endovascular sealing with the Nellix{sup ®} endoprosthesis (EVAS) is a new technique to treat infrarenal abdominal aortic aneurysms. We describe the use of endovascular sealing in conjunction with chimney stents for the renal arteries (chEVAS) in two patients, one with a refractory type Ia endoleak and an expanding aneurysm, and one with a large juxtarenal aneurysm unsuitable for fenestrated endovascular repair (EVAR). Both aneurysms were successfully excluded. Our report confirms the utility of chEVAS in challenging cases, where suprarenal seal is necessary. We suggest that, due to lack of knowledge on its durability, chEVAS should only been considered when moremore » conventional treatment modalities (open repair and fenestrated EVAR) are deemed difficult or unfeasible.« less

  4. Damage Tolerance Assessment of Friction Pull Plug Welds in an Aluminum Alloy

    NASA Technical Reports Server (NTRS)

    McGill, Preston; Burkholder, Jonathan

    2012-01-01

    Friction stir welding is a solid state welding process used in the fabrication of cryogenic propellant tanks. Self-reacting friction stir welding is one variation of the friction stir weld process being developed for manufacturing tanks. Friction pull plug welding is used to seal the exit hole that remains in a circumferential self-reacting friction stir weld. A friction plug weld placed in a self-reacting friction stir weld results in a non-homogenous weld joint where the initial weld, plug weld, their respective heat affected zones and the base metal all interact. The welded joint is a composite plastically deformed material system with a complex residual stress field. In order to address damage tolerance concerns associated with friction plug welds in safety critical structures, such as propellant tanks, nondestructive inspection and proof testing may be required to screen hardware for mission critical defects. The efficacy of the nondestructive evaluation or the proof test is based on an assessment of the critical flaw size. Test data relating residual strength capability to flaw size in an aluminum alloy friction plug weld will be presented.

  5. Automatic orbital GTAW welding: Highest quality welds for tomorrow's high-performance systems

    NASA Technical Reports Server (NTRS)

    Henon, B. K.

    1985-01-01

    Automatic orbital gas tungsten arc welding (GTAW) or TIG welding is certain to play an increasingly prominent role in tomorrow's technology. The welds are of the highest quality and the repeatability of automatic weldings is vastly superior to that of manual welding. Since less heat is applied to the weld during automatic welding than manual welding, there is less change in the metallurgical properties of the parent material. The possibility of accurate control and the cleanliness of the automatic GTAW welding process make it highly suitable to the welding of the more exotic and expensive materials which are now widely used in the aerospace and hydrospace industries. Titanium, stainless steel, Inconel, and Incoloy, as well as, aluminum can all be welded to the highest quality specifications automatically. Automatic orbital GTAW equipment is available for the fusion butt welding of tube-to-tube, as well as, tube to autobuttweld fittings. The same equipment can also be used for the fusion butt welding of up to 6 inch pipe with a wall thickness of up to 0.154 inches.

  6. Method for enhanced control of welding processes

    DOEpatents

    Sheaffer, Donald A.; Renzi, Ronald F.; Tung, David M.; Schroder, Kevin

    2000-01-01

    Method and system for producing high quality welds in welding processes, in general, and gas tungsten arc (GTA) welding, in particular by controlling weld penetration. Light emitted from a weld pool is collected from the backside of a workpiece by optical means during welding and transmitted to a digital video camera for further processing, after the emitted light is first passed through a short wavelength pass filter to remove infrared radiation. By filtering out the infrared component of the light emitted from the backside weld pool image, the present invention provides for the accurate determination of the weld pool boundary. Data from the digital camera is fed to an imaging board which focuses on a 100.times.100 pixel portion of the image. The board performs a thresholding operation and provides this information to a digital signal processor to compute the backside weld pool dimensions and area. This information is used by a control system, in a dynamic feedback mode, to automatically adjust appropriate parameters of a welding system, such as the welding current, to control weld penetration and thus, create a uniform weld bead and high quality weld.

  7. Assessment of Stress Corrosion Cracking Resistance of Activated Tungsten Inert Gas-Welded Duplex Stainless Steel Joints

    NASA Astrophysics Data System (ADS)

    Alwin, B.; Lakshminarayanan, A. K.; Vasudevan, M.; Vasantharaja, P.

    2017-12-01

    The stress corrosion cracking behavior of duplex stainless steel (DSS) weld joint largely depends on the ferrite-austenite phase microstructure balance. This phase balance is decided by the welding process used, heat input, welding conditions and the weld metal chemistry. In this investigation, the influence of activated tungsten inert gas (ATIG) and tungsten inert gas (TIG) welding processes on the stress corrosion cracking (SCC) resistance of DSS joints was evaluated and compared. Boiling magnesium chloride (45 wt.%) environment maintained at 155 °C was used. The microstructure and ferrite content of different weld zones are correlated with the outcome of sustained load, SCC test. Irrespective of the welding processes used, SCC resistance of weld joints was inferior to that of the base metal. However, ATIG weld joint exhibited superior resistance to SCC than the TIG weld joint. The crack initiation and final failure were in the weld metal for the ATIG weld joint; they were in the heat-affected zone for the TIG weld joint.

  8. Weld pool oscillation during GTA welding of mild steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao, Y.H.; Ouden, G. den

    1993-08-01

    In this paper the results are reported of a study dealing with the oscillation behavior of weld pools in the case of GTA bead-on-plate welding of mild steel, Fe 360. During welding, the weld pool was brought into oscillation by applying short current pulses, and the oscillation frequency and amplitude were measured by monitoring the arc voltage. It was found that the oscillation of the partially penetrated weld pool is dominated by one of two different oscillation modes (Mode 1 and Mode 2) depending on the welding conditions, whereas the oscillation of the fully penetrated weld pool is characterized bymore » a third oscillation mode (Mode 3). It is possible to maintain partially penetrated weld pool oscillation in Mode 1 by choosing appropriate welding conditions. Under these conditions, an abrupt decrease in oscillation frequency occurs when the weld pool transfers from partial penetration to full penetration. Thus, weld penetration can be in-process controlled by monitoring the oscillation frequency during welding.« less

  9. Comparison between hybrid laser-MIG welding and MIG welding for the invar36 alloy

    NASA Astrophysics Data System (ADS)

    Zhan, Xiaohong; Li, Yubo; Ou, Wenmin; Yu, Fengyi; Chen, Jie; Wei, Yanhong

    2016-11-01

    The invar36 alloy is suitable to produce mold of composite materials structure because it has similar thermal expansion coefficient with composite materials. In the present paper, the MIG welding and laser-MIG hybrid welding methods are compared to get the more appropriate method to overcome the poor weldability of invar36 alloy. According to the analysis of the experimental and simulated results, it has been proved that the Gauss and cone combined heat source model can characterize the laser-MIG hybrid welding heat source well. The total welding time of MIG welding is 8 times that of hybrid laser-MIG welding. The welding material consumption of MIG welding is about 4 times that of hybrid laser-MIG welding. The stress and deformation simulation indicate that the peak value of deformation during MIG welding is 3 times larger than that of hybrid laser-MIG welding.

  10. Mechanical Characteristics of Welded Joints of Aluminum Alloy 6061 T6 Formed by Arc and Friction Stir Welding

    NASA Astrophysics Data System (ADS)

    Astarita, A.; Squillace, A.; Nele, L.

    2016-01-01

    Butt welds formed by arc welding in inert gas with nonconsumable electrode (tungsten inert gas (TIG) welding) and by friction stir welding (FSW) from aluminum alloy AA6061 T6 are studied. Comparative analysis of the structures and mechanical properties of the welded joints is performed using the results of optical and electron microscopy, tensile tests, tests for residual bending ductility, and measurements of microhardness. The changes in the microstructure in different zones and the degrees of degradation of the mechanical properties after the welding are determined. It is shown that the size of the tool for the friction stir welding affects the properties of the welds. Quantitative results showing the relation between the microscopic behavior of the alloy and the welding-induced changes in the microstructure are obtained. Friction stir welding is shown to provide higher properties of the welds.

  11. Improving the Quality of Welding Seam of Automatic Welding of Buckets Based on TCP

    NASA Astrophysics Data System (ADS)

    Hu, Min

    2018-02-01

    Since February 2014, the welding defects of the automatic welding line of buckets have been frequently appeared. The average repair time of each bucket is 26min, which seriously affects the production efficiency and welding quality. We conducted troubleshooting, and found the main reasons for the welding defects of the buckets were the deviations of the center points of the robot tools and the poor quality of the locating welding. We corrected the gripper, welding torch, and accuracy of repeat positioning of robots to control the quality of positioning welding. The welding defect rate of buckets was reduced greatly, ensuring the production efficiency and welding quality.

  12. Computerized adaptive control weld skate with CCTV weld guidance project

    NASA Technical Reports Server (NTRS)

    Wall, W. A.

    1976-01-01

    This report summarizes progress of the automatic computerized weld skate development portion of the Computerized Weld Skate with Closed Circuit Television (CCTV) Arc Guidance Project. The main goal of the project is to develop an automatic welding skate demonstration model equipped with CCTV weld guidance. The three main goals of the overall project are to: (1) develop a demonstration model computerized weld skate system, (2) develop a demonstration model automatic CCTV guidance system, and (3) integrate the two systems into a demonstration model of computerized weld skate with CCTV weld guidance for welding contoured parts.

  13. Syllabus in Trade Welding.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Bureau of Secondary Curriculum Development.

    The syllabus outlines material for a course two academic years in length (minimum two and one-half hours daily experience) leading to entry-level occupational ability in several welding trade areas. Fourteen units covering are welding, gas welding, oxyacetylene welding, cutting, nonfusion processes, inert gas shielded-arc welding, welding cast…

  14. Filler wire for aluminum alloys and method of welding

    NASA Technical Reports Server (NTRS)

    Bjorkman, Jr., Gerald W. O. (Inventor); Cho, Alex (Inventor); Russell, Carolyn K. (Inventor)

    2003-01-01

    A weld filler wire chemistry has been developed for fusion welding 2195 aluminum-lithium. The weld filler wire chemistry is an aluminum-copper based alloy containing high additions of titanium and zirconium. The additions of titanium and zirconium reduce the crack susceptibility of aluminum alloy welds while producing good weld mechanical properties. The addition of silver further improves the weld properties of the weld filler wire. The reduced weld crack susceptibility enhances the repair weldability, including when planishing is required.

  15. Modeling of plasma and thermo-fluid transport in hybrid welding

    NASA Astrophysics Data System (ADS)

    Ribic, Brandon D.

    Hybrid welding combines a laser beam and electrical arc in order to join metals within a single pass at welding speeds on the order of 1 m min -1. Neither autonomous laser nor arc welding can achieve the weld geometry obtained from hybrid welding for the same process parameters. Depending upon the process parameters, hybrid weld depth and width can each be on the order of 5 mm. The ability to produce a wide weld bead increases gap tolerance for square joints which can reduce machining costs and joint fitting difficulty. The weld geometry and fast welding speed of hybrid welding make it a good choice for application in ship, pipeline, and aerospace welding. Heat transfer and fluid flow influence weld metal mixing, cooling rates, and weld bead geometry. Cooling rate affects weld microstructure and subsequent weld mechanical properties. Fluid flow and heat transfer in the liquid weld pool are affected by laser and arc energy absorption. The laser and arc generate plasmas which can influence arc and laser energy absorption. Metal vapors introduced from the keyhole, a vapor filled cavity formed near the laser focal point, influence arc plasma light emission and energy absorption. However, hybrid welding plasma properties near the opening of the keyhole are not known nor is the influence of arc power and heat source separation understood. A sound understanding of these processes is important to consistently achieving sound weldments. By varying process parameters during welding, it is possible to better understand their influence on temperature profiles, weld metal mixing, cooling rates, and plasma properties. The current literature has shown that important process parameters for hybrid welding include: arc power, laser power, and heat source separation distance. However, their influence on weld temperatures, fluid flow, cooling rates, and plasma properties are not well understood. Modeling has shown to be a successful means of better understanding the influence of processes parameters on heat transfer, fluid flow, and plasma characteristics for arc and laser welding. However, numerical modeling of laser/GTA hybrid welding is just beginning. Arc and laser welding plasmas have been previously analyzed successfully using optical emission spectroscopy in order to better understand arc and laser plasma properties as a function of plasma radius. Variation of hybrid welding plasma properties with radial distance is not known. Since plasma properties can affect arc and laser energy absorption and weld integrity, a better understanding of the change in hybrid welding plasma properties as a function of plasma radius is important and necessary. Material composition influences welding plasma properties, arc and laser energy absorption, heat transfer, and fluid flow. The presence of surface active elements such as oxygen and sulfur can affect weld pool fluid flow and bead geometry depending upon the significance of heat transfer by convection. Easily vaporized and ionized alloying elements can influence arc plasma characteristics and arc energy absorption. The effects of surface active elements on heat transfer and fluid flow are well understood in the case of arc and conduction mode laser welding. However, the influence of surface active elements on heat transfer and fluid flow during keyhole mode laser welding and laser/arc hybrid welding are not well known. Modeling has been used to successfully analyze the influence of surface active elements during arc and conduction mode laser welding in the past and offers promise in the case of laser/arc hybrid welding. A critical review of the literature revealed several important areas for further research and unanswered questions. (1) The understanding of heat transfer and fluid flow during hybrid welding is still beginning and further research is necessary. (2) Why hybrid welding weld bead width is greater than that of laser or arc welding is not well understood. (3) The influence of arc power and heat source separation distance on cooling rates during hybrid welding are not known. (4) Convection during hybrid welding is not well understood despite its importance to weld integrity. (5) The influence of surface active elements on weld geometry, weld pool temperatures, and fluid flow during high power density laser and laser/arc hybrid welding are not known. (6) Although the arc power and heat source separation distance have been experimentally shown to influence arc stability and plasma light emission during hybrid welding, the influence of these parameters on plasma properties is unknown. (7) The electrical conductivity of hybrid welding plasmas is not known, despite its importance to arc stability and weld integrity. In this study, heat transfer and fluid flow are analyzed for laser, gas tungsten arc (GTA), and laser/GTA hybrid welding using an experimentally validated three dimensional phenomenological model. By evaluating arc and laser welding using similar process parameters, a better understanding of the hybrid welding process is expected. The role of arc power and heat source separation distance on weld depth, weld pool centerline cooling rates, and fluid flow profiles during CO2 laser/GTA hybrid welding of 321 stainless steel are analyzed. Laser power is varied for a constant heat source separation distance to evaluate its influence on weld temperatures, weld geometry, and fluid flow during Nd:YAG laser/GTA hybrid welding of A131 structural steel. The influence of oxygen and sulfur on keyhole and weld bead geometry, weld temperatures, and fluid flow are analyzed for high power density Yb doped fiber laser welding of (0.16 %C, 1.46 %Mn) mild steel. Optical emission spectroscopy was performed on GTA, Nd:YAG laser, and Nd:YAG laser/GTA hybrid welding plasmas for welding of 304L stainless steel. Emission spectroscopy provides a means of determining plasma temperatures and species densities using deconvoluted measured spectral intensities, which can then be used to calculate plasma electrical conductivity. In this study, hybrid welding plasma temperatures, species densities, and electrical conductivities were determined using various heat source separation distances and arc currents using an analytical method coupled calculated plasma compositions. As a result of these studies heat transfer by convection was determined to be dominant during hybrid welding of steels. The primary driving forces affecting hybrid welding fluid flow are the surface tension gradient and electromagnetic force. Fiber laser weld depth showed a negligible change when increasing the (0.16 %C, 1.46 %Mn) mild steel sulfur concentration from 0.006 wt% to 0.15 wt%. Increasing the dissolved oxygen content in weld pool from 0.0038 wt% to 0.0257 wt% increased the experimental weld depth from 9.3 mm to 10.8 mm. Calculated partial pressure of carbon monoxide increased from 0.1 atm to 0.75 atm with the 0.0219 wt% increase in dissolved oxygen in the weld metal and may explain the increase in weld depth. Nd:YAG laser/GTA hybrid welding plasma temperatures were calculated to be approximately between 7927 K and 9357 K. Increasing the Nd:YAG laser/GTA hybrid welding heat source separation distance from 4 mm to 6 mm reduced plasma temperatures between 500 K and 900 K. Hybrid welding plasma total electron densities and electrical conductivities were on the order of 1 x 1022 m-3 and 3000 S m-1, respectively.

  16. Programmable Positioner For Spot Welding

    NASA Technical Reports Server (NTRS)

    Roden, William A.

    1989-01-01

    Welding station mechanized by installing preset indexing system and gear drive. Mechanism includes a low-cost, versatile, single-axis motion control and motor drive to provide fully-automatic weld sequencing and spot-to-spot spacing. Welding station relieves operator of some difficult, tedious tasks and increases both productivity and quality of welds. Results in welds of higher quality and greater accuracy, fewer weld defects, and faster welding operation.

  17. Welding polarity effects on weld spatters and bead geometry of hyperbaric dry GMAW

    NASA Astrophysics Data System (ADS)

    Xue, Long; Wu, Jinming; Huang, Junfen; Huang, Jiqiang; Zou, Yong; Liu, Jian

    2016-03-01

    Welding polarity has influence on welding stability to some extent, but the specific relationship between welding polarity and weld quality has not been found, especially under the hyperbaric environment. Based on a hyperbaric dry welding experiment system, gas metal arc welding(GMAW) experiments with direct current electrode positive(DCEP) and direct current electrode negative(DCEN) operations are carried out under the ambient pressures of 0.1 MPa, 0.4 MPa, 0.7 MPa and 1.0 MPa to find the influence rule of different welding polarities on welding spatters and weld bead geometry. The effects of welding polarities on the weld bead geometry such as the reinforcement, the weld width and the penetration are discussed. The experimental results show that the welding spatters gradually grow in quantity and size for GMAW with DCEP, while GMAW with DCEN can produce fewer spatters comparatively with the increase of the ambient pressure. Compared with DCEP, the welding current and arc voltage waveforms for DCEN is more stable and the distribution of welding current probability density for DCEN is more concentrated under the hyperbaric environment. When the ambient pressure is increased from 0.1 MPa to 1.0 MPa, the effects of welding polarities on the reinforcement, the weld width and the penetration are as follows: an increase of 0.8 mm for the weld reinforcement is produced by GMAW with DCEN and 1.3 mm by GMAW with DCEP, a decrease of 7.2 mm for the weld width is produced by DCEN and 6.1 mm by DCEP; and an increase of 3.9 mm for the penetration is produced by DCEN and 1.9 mm by DCEP. The proposed research indicates that the desirable stability in the welding procedure can be achieved by GMAW with DCEN operation under the hyperbaric environment.

  18. Friction Stir Welding

    NASA Technical Reports Server (NTRS)

    Nunes, Arthur C., Jr.

    2008-01-01

    Friction stir welding (FSW) is a solid state welding process invented in 1991 at The Welding Institute in the United Kingdom. A weld is made in the FSW process by translating a rotating pin along a weld seam so as to stir the sides of the seam together. FSW avoids deleterious effects inherent in melting and promises to be an important welding process for any industries where welds of optimal quality are demanded. This article provides an introduction to the FSW process. The chief concern is the physical effect of the tool on the weld metal: how weld seam bonding takes place, what kind of weld structure is generated, potential problems, possible defects for example, and implications for process parameters and tool design. Weld properties are determined by structure, and the structure of friction stir welds is determined by the weld metal flow field in the vicinity of the weld tool. Metal flow in the vicinity of the weld tool is explained through a simple kinematic flow model that decomposes the flow field into three basic component flows: a uniform translation, a rotating solid cylinder, and a ring vortex encircling the tool. The flow components, superposed to construct the flow model, can be related to particular aspects of weld process parameters and tool design; they provide a bridge to an understanding of a complex-at-first-glance weld structure. Torques and forces are also discussed. Some simple mathematical models of structural aspects, torques, and forces are included.

  19. Evaluating the SCC resistance of underwater welds in sodium tetrathionate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, R.A.; Angeliu, T.M.

    1997-12-01

    The susceptibility of welds to stress corrosion cracking (SCC) is enhanced by the surface residual tensile stresses generated by the typical welding process. However, underwater plasma transferred arc (PTA) welding has been shown to produce compressive surface residual stresses, an encouraging result if repairs of cracked boiling water reactor (BWR) components are to be made without further endangering them to SCC. This program was designed to verify that underwater PTA welds are resistant to SCC and to determine if underwater PTA welding could mitigate SCC in potentially susceptible welds. This was achieved by exposing various welds on solution annealed (SA)more » and SA + thermally sensitized 304 stainless steel at 25 C in a solution of 1.5 gm/liter of sodium sulfide added to 0.05M sodium tetrathionate, titrated to a pH of 1.25 with H{sub 2}SO{sub 4}. The autogeneous welds were produced using gas tungsten arc (GTA) and plasma transferred arc (PTA) welding under atmospheric conditions, and PTA welding underwater. After 1 hour of sodium tetrathionate exposure, GTA and air PTA welds exhibited SCC while the underwater PTA weld heat affected zones were more resistant. Underwater PTA welds bisecting a GTA weld eliminated the cracking in the GTA weld heat affected zone under certain conditions. The lack of IG cracking in the region influenced by the underwater PTA weld is consistent with the measurement of compressive surface residual stresses inherent to the underwater welding process.« less

  20. Production of ozone and reactive oxygen species after welding.

    PubMed

    Liu, H H; Wu, Y C; Chen, H L

    2007-11-01

    Many toxic substances including heavy metals, ozone, carbon monoxide, carbon dioxide, and nitrogen oxides are generated during welding. Ozone (O(3)) is a strong oxidant that generates reactive oxygen species (ROS) in tissue, and ambient ROS exposure associated with particles has been determined to cause DNA damage. Ozone is produced within 30 seconds during welding. However, the length of time that O(3) remains in the air after welding is completed (post-welding) is unknown. The current study aimed to assess the distributions of ambient ROS and O(3) before the start of welding (pre-welding), during welding, and after welding. The highest O(3) levels, equal to 195 parts per billion (ppb), appeared during welding. Ozone levels gradually decreased to 60 ppb 10 minutes after the welding was completed. The highest ROS level was found in samples taken during welding, followed by samples taken after the welding was completed. The lowest ROS level was found in samples taken before the welding had started. Ozone and ROS levels were poorly correlated, but a similar trend was found for O(3) and ROS levels in particles (microM/mg). Although particles were not generated after welding, ROS and O(3) still persisted for more than 10 minutes. Meanwhile, because O(3) continues after welding, how long the occupational protective system should be used depends on the welding materials and the methods used. In addition, the relationship between metal fumes and ROS generation during the welding process should be further investigated.

  1. Automatic welding systems for large ship hulls

    NASA Astrophysics Data System (ADS)

    Arregi, B.; Granados, S.; Hascoet, JY.; Hamilton, K.; Alonso, M.; Ares, E.

    2012-04-01

    Welding processes represents about 40% of the total production time in shipbuilding. Although most of the indoor welding work is automated, outdoor operations still require the involvement of numerous operators. To automate hull welding operations is a priority in large shipyards. The objective of the present work is to develop a comprehensive welding system capable of working with several welding layers in an automated way. There are several difficulties for the seam tracking automation of the welding process. The proposed solution is the development of a welding machine capable of moving autonomously along the welding seam, controlling both the position of the torch and the welding parameters to adjust the thickness of the weld bead to the actual gap between the hull plates.

  2. Effect of friction stir welding parameters on defect formation

    NASA Astrophysics Data System (ADS)

    Tarasov, S. Yu.; Rubtsov, V. E.; Eliseev, A. A.; Kolubaev, E. A.; Filippov, A. V.; Ivanov, A. N.

    2015-10-01

    Friction stir welding is a perspective method for manufacturing automotive parts, aviation and space technology. One of the major problems is the formation of welding defects and weld around the welding zone. The formation of defect is the main reason failure of the joint. A possible way to obtain defect-free welded joints is the selection of the correct welding parameters. Experimental results describing the effect of friction stir welding process parameters on the defects of welded joints on aluminum alloy AMg5M have been shown. The weld joint defects have been characterized using the non-destructive radioscopic and ultrasound phase array methods. It was shown how the type and size of defects determine the welded joint strength.

  3. Non-destructive Magnetic Evaluation of Laser Weld Quality in Hot Rolled Coils

    NASA Astrophysics Data System (ADS)

    Mohapatra, J. N.; Chakradhar, I.; Rao, K. R. C.; Rao, V. V. L.; Kaza, Marutiram

    2015-06-01

    Weld quality evaluation was conducted on laser welded thin sectsions (2 mm) of hot-rolled (HR) low-carbon steel coils during cold rolling process. The analysis revealed that the poor welds consisting of the weld defects like incomplete fusion, cluster of porosity, and large difference in hardness between the weld zone and base metal were responsible for the weld failures. Experiments were conducted by varying the welding parameters; laser power and welding speed to optimize the parameters for minimizing the weld defects. The optimized weld process parameters have helped elimination of weld defects and the results are verified with microscopy and microhardness measurements. As destructive evaluation techniques are time consuming and not always permitted in industrial applications, attempts have been made in the present investigation for the utilization of suitable non-destructive techniques for the evaluation of weld quality. Non-destructive magnetic techniques of magnetic hysteresis loop and magnetic Barkhausen emissions were used in the present investigation to establish possible correlations of magnetic properties across the weld seam with the mechanical property (microhardness) for evaluation of weld quality. It is inferred that the magnetic properties of coercivity and inverse of root mean square voltage can be effectively utilized to determine weld quality in HR steel coils.

  4. Tool For Friction Stir Tack Welding of Aluminum Alloys

    NASA Technical Reports Server (NTRS)

    Bjorkman, Gerald W.; Dingler, Johnny W.; Loftus, Zachary

    2003-01-01

    A small friction-stir-welding tool has been developed for use in tack welding of aluminum-alloy workpieces. It is necessary to tack-weld the workpieces in order to hold them together during friction stir welding because (1) in operation, a full-size friction-stir-welding tool exerts a large force that tends to separate the workpieces and (2) clamping the workpieces is not sufficient to resist this force. It is possible to tack the pieces together by gas tungsten arc welding, but the process can be awkward and time-consuming and can cause sufficient damage to necessitate rework. Friction stir tack welding does not entail these disadvantages. In addition, friction stir tack welding can be accomplished by use of the same automated equipment (except for the welding tool) used in subsequent full friction stir welding. The tool for friction stir tack welding resembles the tool for full friction stir welding, but has a narrower shoulder and a shorter pin. The shorter pin generates a smaller workpiece-separating force so that clamping suffices to keep the workpieces together. This tool produces a continuous or intermittent partial-penetration tack weld. The tack weld is subsequently consumed by action of the larger tool used in full friction stir welding tool.

  5. Correlation analysis of the variation of weld seam and tensile strength in laser welding of galvanized steel

    NASA Astrophysics Data System (ADS)

    Sinha, Amit Kumar; Kim, Duck Young; Ceglarek, Darek

    2013-10-01

    Many advantages of laser welding technology such as high speed and non-contact welding make the use of the technology more attractive in the automotive industry. Many studies have been conducted to search the optimal welding condition experimentally that ensure the joining quality of laser welding that relies both on welding system configuration and welding parameter specification. Both non-destructive and destructive techniques, for example, ultrasonic inspection and tensile test are widely used in practice for estimating the joining quality. Non-destructive techniques are attractive as a rapid quality testing method despite relatively low accuracy. In this paper, we examine the relationship between the variation of weld seam and tensile shear strength in the laser welding of galvanized steel in a lap joint configuration in order to investigate the potential of the variation of weld seam as a joining quality estimator. From the experimental analysis, we identify a trend in between maximum tensile shear strength and the variation of weld seam that clearly supports the fact that laser welded parts having larger variation in the weld seam usually have lower tensile strength. The discovered relationship leads us to conclude that the variation of weld seam can be used as an indirect non-destructive testing method for estimating the tensile strength of the welded parts.

  6. Selection of optimal welding condition for GTA pulse welding in root-pass of V-groove butt joint

    NASA Astrophysics Data System (ADS)

    Yun, Seok-Chul; Kim, Jae-Woong

    2010-12-01

    In the manufacture of high-quality welds or pipeline, a full-penetration weld has to be made along the weld joint. Therefore, root-pass welding is very important, and its conditions have to be selected carefully. In this study, an experimental method for the selection of optimal welding conditions is proposed for gas tungsten arc (GTA) pulse welding in the root pass which is done along the V-grooved butt-weld joint. This method uses response surface analysis in which the width and height of back bead are chosen as quality variables of the weld. The overall desirability function, which is the combined desirability function for the two quality variables, is used as the objective function to obtain the optimal welding conditions. In our experiments, the target values of back bead width and height are 4 mm and zero, respectively, for a V-grooved butt-weld joint of a 7-mm-thick steel plate. The optimal welding conditions could determine the back bead profile (bead width and height) as 4.012 mm and 0.02 mm. From a series of welding tests, it was revealed that a uniform and full-penetration weld bead can be obtained by adopting the optimal welding conditions determined according to the proposed method.

  7. Recent Developments and Research Progress on Friction Stir Welding of Titanium Alloys: An Overview

    NASA Astrophysics Data System (ADS)

    Karna, Sivaji; Cheepu, Muralimohan; Venkateswarulu, D.; Srikanth, V.

    2018-03-01

    Titanium and its alloys are joined by various welding processes. However, Fusion welding of titanium alloys resulted solidification problems like porosity, segregation and columnar grains. The problems occurred in conventional welding processes can be resolved using a solid state welding i.e. friction stir welding. Aluminium and Magnesium alloys were welded by friction stir welding. However alloys used for high temperature applications such as titanium alloys and steels are arduous to weld using friction stir welding process because of tool limitations. Present paper summarises the studies on joining of Titanium alloys using friction stir welding with different tool materials. Selection of tool material and effect of welding conditions on mechanical and microstructure properties of weldments were also reported. Major advantage with friction stir welding is, we can control the welding temperature above or below β-transus temperature by optimizing the process parameters. Stir zone in below beta transus condition consists of bi-modal microstructure and microstructure in above β-transus condition has large prior β- grains and α/β laths present in the grain. Welding experiments conducted below β- transus condition has better mechanical properties than welding at above β-transus condition. Hardness and tensile properties of weldments are correlated with the stir zone microstructure.

  8. Comparison of Tensile Damage Evolution in Ti6A14V Joints Between Laser Beam Welding and Gas Tungsten Arc Welding

    NASA Astrophysics Data System (ADS)

    Gao, Xiao-Long; Zhang, Lin-Jie; Liu, Jing; Zhang, Jian-Xun

    2014-12-01

    The present paper studied the evolution of tensile damage in joints welded using laser beam welding (LBW) and gas tungsten arc welding (TIG) under a uniaxial tensile load. The damage evolution in the LBW joints and TIG-welded joints was studied by using digital image correlation (DIC) technology and monitoring changes in Young's modulus during tensile testing. To study the mechanism of void nucleation and growth in the LBW joints and TIG-welded joints, test specimens with various amounts of plastic deformation were analyzed using a scanning electron microscope (SEM). Compared with TIG-welded joints, LBW-welded joints have a finer microstructure and higher microhardness in the fusion zone. The SEM analysis and DIC test results indicated that the critical strain of void nucleation was greater in the LBW-welded joints than in the TIG-welded joints, while the growth rate of voids was lower in the LBW-welded joints than in the TIG-welded joints. Thus, the damage ratio in the LBW joints was lower than that in the TIG-welded joints during tensile testing. This can be due to the coarser martensitic α' and the application of TC-1 welding rods in the TIG-welded joint.

  9. Welding characteristics of 27, 40 and 67 kHz ultrasonic plastic welding systems using fundamental- and higher-resonance frequencies.

    PubMed

    Tsujino, Jiromaru; Hongoh, Misugi; Yoshikuni, Masafumi; Hashii, Hidekazu; Ueoka, Tetsugi

    2004-04-01

    The welding characteristics of 27, 40 and 67 kHz ultrasonic plastic welding systems that are driven at only the fundamental-resonance frequency vibration were compared, and also those of the welding systems that were driven at the fundamental and several higher resonance frequencies simultaneously were studied. At high frequency, welding characteristics can be improved due to the larger vibration loss of plastic materials. For welding of rather thin or small specimens, as the fundamental frequency of these welding systems is higher and the numbers of driven higher frequencies are driven simultaneously, larger welded area and weld strength were obtained.

  10. Intelligent Modeling Combining Adaptive Neuro Fuzzy Inference System and Genetic Algorithm for Optimizing Welding Process Parameters

    NASA Astrophysics Data System (ADS)

    Gowtham, K. N.; Vasudevan, M.; Maduraimuthu, V.; Jayakumar, T.

    2011-04-01

    Modified 9Cr-1Mo ferritic steel is used as a structural material for steam generator components of power plants. Generally, tungsten inert gas (TIG) welding is preferred for welding of these steels in which the depth of penetration achievable during autogenous welding is limited. Therefore, activated flux TIG (A-TIG) welding, a novel welding technique, has been developed in-house to increase the depth of penetration. In modified 9Cr-1Mo steel joints produced by the A-TIG welding process, weld bead width, depth of penetration, and heat-affected zone (HAZ) width play an important role in determining the mechanical properties as well as the performance of the weld joints during service. To obtain the desired weld bead geometry and HAZ width, it becomes important to set the welding process parameters. In this work, adaptative neuro fuzzy inference system is used to develop independent models correlating the welding process parameters like current, voltage, and torch speed with weld bead shape parameters like depth of penetration, bead width, and HAZ width. Then a genetic algorithm is employed to determine the optimum A-TIG welding process parameters to obtain the desired weld bead shape parameters and HAZ width.

  11. Studies on A-TIG welding of Low Activation Ferritic/Martensitic (LAFM) steel

    NASA Astrophysics Data System (ADS)

    Vasantharaja, P.; Vasudevan, M.

    2012-02-01

    Low Activation Ferritic-Martensitic steels (LAFM) are chosen as the candidate material for structural components in fusion reactors. The structural components are generally fabricated by welding processes. Activated Tungsten Inert Gas (A-TIG) welding is an emerging process for welding of thicker components. In the present work, attempt was made to develop A-TIG welding technology for LAFM steel plates of 10 mm thick. Activated flux was developed for LAFM steel by carrying out various bead-on-plate TIG welds without flux and with flux. The optimum flux was identified as one which gave maximum depth of penetration at minimum heat input values. With the optimized flux composition, LAFM steel plate of 10 mm thickness was welded in square butt weld joint configuration using double side welding technique. Optical and Scanning Electron Microscopy was used for characterizing the microstructures. Microhardness measurements were made across the weld cross section for as welded and post weld heat treated samples. Tensile and impact toughness properties were determined. The mechanical properties values obtained in A-TIG weld joint were comparable to that obtained in weld joints of LAFM steel made by Electron beam welding process.

  12. Application of YAG Laser TIG Arc Hybrid Welding to Thin AZ31B Magnesium Alloy Sheet

    NASA Astrophysics Data System (ADS)

    Kim, Taewon; Kim, Jongcheol; Hasegawa, Yu; Suga, Yasuo

    A magnesium alloy is said to be an ecological material with high ability of recycling and lightweight property. Especially, magnesium alloys are in great demand on account of outstanding material property as a structural material. Under these circumstances, research and development of welding process to join magnesium alloy plates are of great significance for wide industrial application of magnesium. In order to use it as a structure material, the welding technology is very important. TIG arc welding process is the most ordinary process to weld magnesium alloy plates. However, since the heat source by the arc welding process affects the magnesium alloy plates, HAZ of welded joint becomes wide and large distortion often occurs. On the other hand, a laser welding process that has small diameter of heat source seems to be one of the possible means to weld magnesium alloy in view of the qualitative improvement. However, the low boiling point of magnesium generates some weld defects, including porosity and solidification cracking. Furthermore, precise edge preparation is very important in butt-welding by the laser welding process, due to the small laser beam diameter. Laser/arc hybrid welding process that combines the laser beam and the arc is an effective welding process in which these two heat sources influence and assist each other. Using the hybrid welding, a synegistic effect is achievable and the disadvantages of the respective processes can be compensated. In this study, YAG laser/TIG arc hybrid welding of thin magnesium alloy (AZ31B) sheets was investigated. First of all, the effect of the irradiation point and the focal position of laser beam on the quality of a weld were discussed in hybrid welding. Then, it was confirmed that a sound weld bead with sufficient penetration is obtained using appropriate welding conditions. Furthermore, it was made clear that the heat absorption efficiency is improved with the hybrid welding process. Finally, the tensile tests of welded joints were performed, and it was confirmed that they have sufficient mechanical properties. As a result of this study, it is confirmed that, if the appropriate welding conditions are selected, sound welded joints of AZ31B magnesium alloy are obtainable by the YAG laser/TIG arc hybrid welding process.

  13. Survey of welding processes.

    DOT National Transportation Integrated Search

    2003-07-01

    The current KYTC SPECIAL PROVISION NO. 4 WELDING STEEL BRIDGES prohibits the use of welding processes other than shielded metal arc welding (SMAW) and submerged arc welding (SAW). Nationally, bridge welding is codified under ANSI/AASHTO/AWS D1....

  14. Effect of Shielding Gas on the Properties of AW 5083 Aluminum Alloy Laser Weld Joints

    NASA Astrophysics Data System (ADS)

    Vyskoč, Maroš; Sahul, Miroslav; Sahul, Martin

    2018-04-01

    The paper deals with the evaluation of the shielding gas influence on the properties of AW 5083 aluminum alloy weld joints produced with disk laser. Butt weld joints were produced under different shielding gas types, namely Ar, He, Ar + 5 vol.% He, Ar + 30 vol.% He and without shielding weld pool. Light and electron microscopy, computed tomography, microhardness measurements and tensile testing were used for evaluation of weld joint properties. He-shielded weld joints were the narrowest ones. On the other hand, Ar-shielded weld joints exhibited largest weld width. The choice of shielding gas had significant influence on the porosity level of welds. The lowest porosity was observed in weld joint produced in Ar with the addition of 5 vol.% He shielding atmosphere (only 0.03%), while the highest level of porosity was detected in weld joint produced in pure He (0.24%). Except unshielded aluminum alloy weld joint, the lowest tensile strength was recorded in He-shielded weld joints. On the contrary, the highest average microhardness was measured in He-shielded weld joints.

  15. Computational simulation of weld microstructure and distortion by considering process mechanics

    NASA Astrophysics Data System (ADS)

    Mochizuki, M.; Mikami, Y.; Okano, S.; Itoh, S.

    2009-05-01

    Highly precise fabrication of welded materials is in great demand, and so microstructure and distortion controls are essential. Furthermore, consideration of process mechanics is important for intelligent fabrication. In this study, the microstructure and hardness distribution in multi-pass weld metal are evaluated by computational simulations under the conditions of multiple heat cycles and phase transformation. Because conventional CCT diagrams of weld metal are not available even for single-pass weld metal, new diagrams for multi-pass weld metals are created. The weld microstructure and hardness distribution are precisely predicted when using the created CCT diagram for multi-pass weld metal and calculating the weld thermal cycle. Weld distortion is also investigated by using numerical simulation with a thermal elastic-plastic analysis. In conventional evaluations of weld distortion, the average heat input has been used as the dominant parameter; however, it is difficult to consider the effect of molten pool configurations on weld distortion based only on the heat input. Thus, the effect of welding process conditions on weld distortion is studied by considering molten pool configurations, determined by temperature distribution and history.

  16. A fundamental study on the structural integrity of magnesium alloys joined by friction stir welding

    NASA Astrophysics Data System (ADS)

    Rao, Harish Mangebettu

    The goal of this research is to study the factors that influence the physical and mechanical properties of lap-shear joints produced using friction stir welding. This study focuses on understanding the effect of tool geometry and weld process parameters including the tool rotation rate, tool plunge depth and dwell time on the mechanical performance of similar magnesium alloy and dissimilar magnesium to aluminum alloy weld joints. A variety of experimental activities were conducted including tensile and fatigue testing, fracture surface and failure analysis, microstructure characterization, hardness measurements and chemical composition analysis. An investigation on the effect of weld process conditions in friction stir spot welding of magnesium to magnesium produced in a manner that had a large effective sheet thickness and smaller interfacial hook height exhibited superior weld strength. Furthermore, in fatigue testing of friction stir spot welded of magnesium to magnesium alloy, lap-shear welds produced using a triangular tool pin profile exhibited better fatigue life properties compared to lap-shear welds produced using a cylindrical tool pin profile. In friction stir spot welding of dissimilar magnesium to aluminum, formation of intermetallic compounds in the stir zone of the weld had a dominant effect on the weld strength. Lap-shear dissimilar welds with good material mixture and discontinues intermetallic compounds in the stir zone exhibited superior weld strength compared to lap-shear dissimilar welds with continuous formation of intermetallic compounds in the stir zone. The weld structural geometry like the interfacial hook, hook orientation and bond width also played a major role in influencing the weld strength of the dissimilar lap-shear friction stir spot welds. A wide scatter in fatigue test results was observed in friction stir linear welds of aluminum to magnesium alloys. Different modes of failure were observed under fatigue loading including crack propagation into the top sheet, into the bottom sheet, and interfacial separation. Investigation of the tested welds revealed that the voids in the weld nugget reduced the weld strength, resulting in lower fatigue life. A thin layer of IMCs formed along the faying surface which accelerated the fatigue failure.

  17. Gravitational effects on weld pool shape and microstructural evolution during gas tungsten arc and laser beam welding on 304 stainless steel, nickel, and aluminum-4 wt.% copper alloy

    NASA Astrophysics Data System (ADS)

    Kang, Namhyun

    The objective of the present work was to investigate effects of gravitational (acceleration) level and orientation on Ni 200 alloy (99.5% Ni purity), 304 stainless steel, and Al-4 wt.% Cu alloy during gas tungsten arc welding (GTAW) and laser beam welding (LBW). Main characterization was focused on the weld pool shape, microstructure, and solute distribution as a function of gravitational level and orientation. The welds were divided into two classes, i.e., 'stable' and 'unstable' welds, in view of the variation of weld pool shape as a function of gravitational level and orientation. In general, higher arc current and translational GTAW produced more significant effects of gravitational orientation on the weld pool shape than the case of lower arc current and spot welding. Cross-sectional area (CSA) was a secondary factor in determining the stability of weld pool shape. For the 'stable' weld of 304 stainless steel GTAW, the II-U weld showed less convexity in the pool bottom and more depression of the free surface, therefore producing deeper penetration (10--20%) than the case of II-D weld. The II-D weld of 304 stainless steel showed 31% deeper penetration, 28% narrower width, and more hemispherical shape of the weld pool than the case of II-U weld. For GTAW on 304 stainless steel, gravitational level variation from low gravity (LG ≈ 1.2 go) to high gravity (HG ≈ 1.8 go) caused 10% increase in width and 10% decrease in depth while maintaining the overall weld pool volume. Furthermore, LBW on 304 stainless steels showed mostly constant shape of weld pool as a function of gravitational orientation. GTAW on Ni showed similar trends of weld pool shape compared with GTAW on 304 stainless steel, i.e., the weld pool became unstable by showing more penetration in the II-D weld for slower arc translational velocity (V a) and larger weld pool size. However, the Ni weld pool shape had greater stability of the weld pool shape with respect to the gravitational orientation than the case of 304 stainless steel, i.e., higher current boundary and no humping. Regardless of the gravitational level, the ferrite content and the distribution of the solutes (Cr and Ni) remained constant for GTAW on 304 stainless steel. However, for GTAW on Al-4 wt.% Cu alloys, the gravitational orientation changed the weld pool shape associated with convection flows. In summary, gravity influenced the weld pool shape that was associated with convection flows and weld surface deformation for specific welding conditions. The variation of convection flows and weld pool shape played a role in modifying VS and GL. Solidification orientation and morphology were affected because VS and GL were changed as a function of gravity. Studies of gravity on the welding process are expected to play a significant role in the space-station construction and circumferential pipe welding on the earth. (Abstract shortened by UMI.)

  18. Fast, Nonspattering Inert-Gas Welding

    NASA Technical Reports Server (NTRS)

    Gilbert, Jeffrey L.

    1991-01-01

    Proposed welding technique combines best features of metal (other than tungsten)/inert-gas welding, plasma arc welding, and tungsten/inert-gas welding. Advantages include: wire fed to weld joint preheated, therefore fed at high speed without spattering; high-frequency energy does not have to be supplied to workpiece to initiate welding; size of arc gap not critical, power-supply control circuit adjusts voltage across gap to compensate for changes; only low gas-flow rate needed; welding electrode replaced easily as prefabricated assembly; external wire-feeding manipulator not needed; and welding process relatively forgiving of operator error.

  19. Characteristics of Extra Narrow Gap Weld of HSLA Steel Welded by Single-Seam per Layer Pulse Current GMA Weld Deposition

    NASA Astrophysics Data System (ADS)

    Agrawal, B. P.; Ghosh, P. K.

    2017-03-01

    Butt weld joints are produced using pulse current gas metal arc welding process by employing the technique of centrally laid multi-pass single-seam per layer weld deposition in extra narrow groove of thick HSLA steel plates. The weld joints are prepared by using different combination of pulse parameters. The selection of parameter of pulse current gas metal arc welding is done considering a summarized influence of simultaneously interacting pulse parameters defined by a dimensionless hypothetical factor ϕ. The effect of diverse pulse parameters on the characteristics of weld has been studied. Weld joint is also prepared by using commonly used multi-pass multi-seam per layer weld deposition in conventional groove. The extra narrow gap weld joints have been found much superior to the weld joint prepared by multi-pass multi-seam per layer deposition in conventional groove with respect to its metallurgical characteristics and mechanical properties.

  20. Influence of shielding gas pressure on welding characteristics in CO2 laser-MIG hybrid welding process

    NASA Astrophysics Data System (ADS)

    Chen, Yanbin; Lei, Zhenglong; Li, Liqun; Wu, Lin

    2006-01-01

    The droplet transfer behavior and weld characteristics have been investigated under different pressures of shielding gas in CO2 laser and metal inert/active gas (laser-MIG) hybrid welding process. The experimental results indicate that the inherent droplet transfer frequency and stable welding range of conventional MIG arc are changed due to the interaction between CO2 laser beam and MIG arc in laser-MIG hybrid welding process, and the shielding gas pressure has a crucial effect on welding characteristics. When the pressure of shielding gas is low in comparison with MIG welding, the frequency of droplet transfer decreases, and the droplet transfer becomes unstable in laser-MIG hybrid welding. So the penetration depth decreases, which shows the characteristic of unstable hybrid welding. However, when the pressure of shielding gas increases to a critical value, the hybrid welding characteristic is changed from unstable hybrid welding to stable hybrid welding, and the frequency of droplet transfer and the penetration depth increase significantly.

  1. Effects of conventional welding and laser welding on the tensile strength, ultimate tensile strength and surface characteristics of two cobalt-chromium alloys: a comparative study.

    PubMed

    Madhan Kumar, Seenivasan; Sethumadhava, Jayesh Raghavendra; Anand Kumar, Vaidyanathan; Manita, Grover

    2012-06-01

    The purpose of this study was to evaluate the efficacy of laser welding and conventional welding on the tensile strength and ultimate tensile strength of the cobalt-chromium alloy. Samples were prepared with two commercially available cobalt-chromium alloys (Wironium plus and Diadur alloy). The samples were sectioned and the broken fragments were joined using Conventional and Laser welding techniques. The welded joints were subjected to tensile and ultimate tensile strength testing; and scanning electron microscope to evaluate the surface characteristics at the welded site. Both on laser welding as well as on conventional welding technique, Diadur alloy samples showed lesser values when tested for tensile and ultimate tensile strength when compared to Wironium alloy samples. Under the scanning electron microscope, the laser welded joints show uniform welding and continuous molt pool all over the surface with less porosity than the conventionally welded joints. Laser welding is an advantageous method of connecting or repairing cast metal prosthetic frameworks.

  2. Effect of FSW welding speed on microstructure and microhardness of Al-0.84Mg-0.69Si-0.76Fe alloy at moderate rotational tool velocity

    NASA Astrophysics Data System (ADS)

    Chand, Suresh; Vineetha, S.; Madhusudhan, D.; Sai Krishna, CH; Kusuma Devi, G.; Bhawani; Hemarao, K.; Ganesh Naidu, G.

    2018-03-01

    The plate of 7.0 mm thickness was double side welded using friction stir welding is investigated. The rotational velocity of friction stir welding tool is used 1400 rpm. The influence of welding speed on the microstructure and microhardness values of Al-0.84Mg-0.69Si-0.76Fe aluminum alloy is presented. Two welding speeds 25 mm/min and 31.5 mm/min are used. The microhardness values of friction stir weld are measured at various locations from the weld interface. The microhardness values in stir zone of weld are found larger than lower welding speed at constant rotational velocity of 1400 rpm of friction stir welding tool. The similar effects on microhardness values are found in the thermo-mechanically affected zone and heat affected zone. The fine microstructure is observed at 31.5 mm/min welding speed compared to the 25 mm/min welding speed at 1400 rpm.

  3. Automatic hot wire GTA welding of pipe offers speed and increased deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sykes, I.; Digiacomo, J.

    1995-07-01

    Heavy-wall pipe welding for the power and petrochemical industry must meet code requirements. Contractors strive to meet these requirements in the most productive way possible. The challenge put to orbital welding equipment manufacturers is to produce pipe welding equipment that cost-effectively produces code-quality welds. Orbital welding equipment using the GTA process has long produced outstanding quality results but has lacked the deposition rate to compete cost effectively with other manual and semiautomatic processes such as SMAW, FCAW and GMAW. In recent years, significant progress has been made with the use of narrow-groove weld joint designs to reduce weld joint volumemore » and improve welding times. Astro Arc Polysoude, an orbital welding equipment manufacturer based in Sun Valley, Calif., and Nantes, France, has combined the hot wire GTAW process with orbital welding equipment using a narrow-groove weld joint design. Field test results show this process and procedure is a good alternative for many heavy-wall-pipe welding applications.« less

  4. Monitoring the quality of welding based on welding current and ste analysis

    NASA Astrophysics Data System (ADS)

    Mazlan, Afidatusshimah; Daniyal, Hamdan; Izzani Mohamed, Amir; Ishak, Mahadzir; Hadi, Amran Abdul

    2017-10-01

    Qualities of welding play an important part in industry especially in manufacturing field. Post-welding non-destructive test is one of the importance process to ensure the quality of welding but it is time consuming and costly. To reduce the chance of defects, online monitoring had been utilized by continuously sense some of welding parameters and predict welding quality. One of the parameters is welding current, which is rich of information but lack of study focus on extract them at signal analysis level. This paper presents the analysis of welding current using Short Time Energy (STE) signal processing to quantify the pattern of the current. GMAW set with carbon steel specimens are used in this experimental study with high-bandwidth and high sampling rate oscilloscope capturing the welding current. The results indicate welding current as signatures have high correlation with the welding process. Continue with STE analysis, the value below 5000 is declare as good welding, meanwhile the STE value more than 6000 is contained defect.

  5. Sensors control gas metal arc welding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siewert, T.A.; Madigan, R.B.; Quinn, T.P.

    1997-04-01

    The response time of a trained welder from the time a weld problem is identified to the time action is taken is about one second--especially after a long, uneventful period of welding. This is acceptable for manual welding because it is close to the time it takes for the weld pool to solidify. If human response time were any slower, manual welding would not be possible. However, human response time is too slow to respond to some weld events, such as melting of the contact tube in gas metal arc welding (GMAW), and only automated intelligent control systems can reactmore » fast enough to correct or avoid these problems. Control systems incorporate welding knowledge that enables intelligent decisions to be made about weld quality and, ultimately, to keep welding parameters in the range where only high-quality welds are produced. This article discusses the correlation of electrical signals with contact-tube wear, changes in shielding gas, changes in arc length, and other weld process data.« less

  6. CBCT-based 3D MRA and angiographic image fusion and MRA image navigation for neuro interventions.

    PubMed

    Zhang, Qiang; Zhang, Zhiqiang; Yang, Jiakang; Sun, Qi; Luo, Yongchun; Shan, Tonghui; Zhang, Hao; Han, Jingfeng; Liang, Chunyang; Pan, Wenlong; Gu, Chuanqi; Mao, Gengsheng; Xu, Ruxiang

    2016-08-01

    Digital subtracted angiography (DSA) remains the gold standard for diagnosis of cerebral vascular diseases and provides intraprocedural guidance. This practice involves extensive usage of x-ray and iodinated contrast medium, which can induce side effects. In this study, we examined the accuracy of 3-dimensional (3D) registration of magnetic resonance angiography (MRA) and DSA imaging for cerebral vessels, and tested the feasibility of using preprocedural MRA for real-time guidance during endovascular procedures.Twenty-three patients with suspected intracranial arterial lesions were enrolled. The contrast medium-enhanced 3D DSA of target vessels were acquired in 19 patients during endovascular procedures, and the images were registered with preprocedural MRA for fusion accuracy evaluation. Low-dose noncontrasted 3D angiography of the skull was performed in the other 4 patients, and registered with the MRA. The MRA was overlaid afterwards with 2D live fluoroscopy to guide endovascular procedures.The 3D registration of the MRA and angiography demonstrated a high accuracy for vessel lesion visualization in all 19 patients examined. Moreover, MRA of the intracranial vessels, registered to the noncontrasted 3D angiography in the 4 patients, provided real-time 3D roadmap to successfully guide the endovascular procedures. Radiation dose to patients and contrast medium usage were shown to be significantly reduced.Three-dimensional MRA and angiography fusion can accurately generate cerebral vasculature images to guide endovascular procedures. The use of the fusion technology could enhance clinical workflow while minimizing contrast medium usage and radiation dose, and hence lowering procedure risks and increasing treatment safety.

  7. CBCT-based 3D MRA and angiographic image fusion and MRA image navigation for neuro interventions

    PubMed Central

    Zhang, Qiang; Zhang, Zhiqiang; Yang, Jiakang; Sun, Qi; Luo, Yongchun; Shan, Tonghui; Zhang, Hao; Han, Jingfeng; Liang, Chunyang; Pan, Wenlong; Gu, Chuanqi; Mao, Gengsheng; Xu, Ruxiang

    2016-01-01

    Abstract Digital subtracted angiography (DSA) remains the gold standard for diagnosis of cerebral vascular diseases and provides intraprocedural guidance. This practice involves extensive usage of x-ray and iodinated contrast medium, which can induce side effects. In this study, we examined the accuracy of 3-dimensional (3D) registration of magnetic resonance angiography (MRA) and DSA imaging for cerebral vessels, and tested the feasibility of using preprocedural MRA for real-time guidance during endovascular procedures. Twenty-three patients with suspected intracranial arterial lesions were enrolled. The contrast medium-enhanced 3D DSA of target vessels were acquired in 19 patients during endovascular procedures, and the images were registered with preprocedural MRA for fusion accuracy evaluation. Low-dose noncontrasted 3D angiography of the skull was performed in the other 4 patients, and registered with the MRA. The MRA was overlaid afterwards with 2D live fluoroscopy to guide endovascular procedures. The 3D registration of the MRA and angiography demonstrated a high accuracy for vessel lesion visualization in all 19 patients examined. Moreover, MRA of the intracranial vessels, registered to the noncontrasted 3D angiography in the 4 patients, provided real-time 3D roadmap to successfully guide the endovascular procedures. Radiation dose to patients and contrast medium usage were shown to be significantly reduced. Three-dimensional MRA and angiography fusion can accurately generate cerebral vasculature images to guide endovascular procedures. The use of the fusion technology could enhance clinical workflow while minimizing contrast medium usage and radiation dose, and hence lowering procedure risks and increasing treatment safety. PMID:27512846

  8. Endovascular treatment of peripheral and visceral arterial injuries in patients with acute trauma.

    PubMed

    Erbahçeci Salık, Aysun; Saçan İslim, Filiz; Çil, Barbaros Erhan

    2016-11-01

    The present study is an evaluation of the efficacy of endovascular treatment in emergency setting for patients with acute peripheral and visceral arterial injury secondary to penetrating or blunt trauma. Twelve patients (11 men) aged 35.8±11.3 years (range: 18-56 years) with penetrating or blunt trauma who underwent endovascular treatment in our department between March 2010 and June 2014 for peripheral and visceral arterial injury were retrospectively reviewed. Selective coil embolization was performed on 11 patients and particle embolization of the injured vessel was performed on 1 patient. Criteria for endovascular treatment included active extravasation or pseudoaneurysm on contrast-enhanced computed tomography and decrease in hemoglobin level or temporary hemodynamic instability. Arterial injuries were secondary to penetrating injury due to gunshot wound in 4 patients and stab wound in 5, and blunt abdominal injury as result of traffic accident in 3 patients. Traumatic lesions were in the right hepatic artery (n=3), left hepatic (n=2), right hepatic and right renal (n=1), left inferior epigastric (n=2), left facial (n=1), anterior tibial (n=1), and deep femoral (n=1) arteries. Technical success with no procedural complications was seen in all cases. Two patients died due to coexisting injuries on 29th and 43rd days of hospitalization. Median hospitalization period was 6.0 days (range: 1-43 days) and mean intensive care unit hospitalization was 7.7 days (range: 0-43 days). In our experience, endovascular treatment was a safe and effective option for acute traumatic peripheral and visceral arterial lesions.

  9. The role of robotic surgical system in the management of vascular disease.

    PubMed

    Lin, Judith C

    2013-10-01

    The evolution of minimally invasive treatment for aneurysms and occlusive disease has led to the development of endovascular, laparoscopic, and robot-assisted techniques. This article reviews the current literature on the clinical use of robotic surgical systems in the treatment of patients with aneurysms and occlusive disease. A MEDLINE search was performed using the keywords "robotic, vascular, AND surgery." All pertinent articles concerning the use of the robotic surgical system on aneurysms and occlusive disease were reviewed. The author's personal experience consisted of a retrospective review of a prospectively maintained confidential database on all procedures performed with the da Vinci(®) surgical system. Several robot-assisted laparoscopic series on the treatment of aortic disease were identified, including review articles of potential clinical applications in hybrid, laparoscopic vascular, and endovascular treatments for vascular patients using robotic technology. The use of computer-enhanced or robotic technology as a sole modality for bypass of occlusive disease and repair of abdominal aortic, splenic, and renal aneurysms was described in case series with satisfactory patient outcomes. Current robotic endovascular technology was also described. Minimally invasive techniques using endovascular, laparoscopic, or robot-assisted technology have revolutionized the treatment of aortoiliac, splanchnic, and renal aneurysms and occlusive disease. However, robot-assisted techniques for aortic disease may involve a learning curve and increased operating times. Although endovascular therapy is preferred because of faster recovery, this preference for improved short-term outcomes will be balanced with the superiority and durability of robot-assisted endoscopic methods as comparable to open surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Targeting clinical outcomes: Endovascular simulation improves diagnostic coronary angiography skills.

    PubMed

    Schimmel, Daniel R; Sweis, Ranya; Cohen, Elaine R; Davidson, Charles; Wayne, Diane B

    2016-02-15

    The purpose of this study is to determine the effects of simulation-based medical education (SBME) on the skills required to perform coronary angiography in the cardiac catheterization laboratory. Cardiovascular fellows commonly learn invasive procedures on patients. Because this approach is not standardized, it can result in inconsistent skill acquisition through exclusion of concepts and skills. Also, the learning curve varies between trainees yielding variability in skill acquisition. Therefore, coronary angiography skills are an excellent target for SBME in an environment in which direct patient care is not jeopardized. From January 2013 to June 2013, 14 cardiovascular fellows entering the cardiac catheterization laboratory at a tertiary care teaching hospital were tested on an endovascular simulator to assess baseline skills. All fellows subsequently underwent didactic teaching and preceptor-lead training on the endovascular simulator. Topics included basic catheterization skills and a review of catheterization laboratory systems. Following training, all fellows underwent a post-training assessment on the endovascular simulator. Paired t tests were used to compare items on the skills checklist and simulator defined variables. Cardiovascular fellows scored significantly higher on a diagnostic coronary angiography skills checklist following SBME using an endovascular simulator. The mean pretest score was 66.6% (SD = 9.7%) compared to 86.0% (SD = 6.3%) following simulator training (P < 0.001). Additional findings include significant reduction in procedure time and use of cine-fluoroscopy at posttest. SBME significantly improved cardiovascular fellows' performance of simulated coronary angiography skills. Standardized simulation-based education is a valuable adjunct to traditional clinical education for cardiovascular fellows. © 2015 Wiley Periodicals, Inc.

  11. Endovascular Repair of Localized Pathological Lesions of the Descending Thoracic Aorta: Midterm Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Attia, Cherif; Villard, Jacques; Boussel, Loic

    The endoluminal stent-graft represents an attractive and a less invasive technique for treatment of various diseases of the descending thoracic aorta. The purpose of this study was to evaluate the Talent endovascular stent-graft for the treatment of various localized diseases of the descending thoracic aorta. Over a 3-year period, Talent thoracic endografts were placed in 40 patients with a high surgical risk, presenting a localized lesion of the descending thoracic aorta: degenerative aneurysm (n = 13), acute traumatic rupture (n = 11), acute Stanford type B aortic dissection (n = 6), false aneurysm (n = 7), and penetrating atherosclerotic ulcermore » (n = 3). Fifteen patients (37.5%) were treated as emergencies. The feasibility of endovascular treatment and sizing of the aorta and stent-grafts were determined preoperatively by magnetic resonance angiography (MRA) and intraoperative angiography. Immediate and mid-term technical and clinical success was assessed by clinical and MRA follow-up. Endovascular treatment was completed successfully in all 40 patients, with no conversion to open repair or intraoperative mortality. The mean operative time was 37.5 {+-} 7 min. The overall 30-day mortality rate was 10% (n = 4), all in emergency cases, for causes not related to the endograft. The primary technical success was 92.5%. The mean follow-up period was 15 {+-} 5 months. The survival rate was 95% (n = 35). Diminution of the aneurismal size was observed in 47.5% (n = 19). We conclude that endovascular treatment of the various localized diseases of the descending thoracic aorta is a promising, feasible, alternative technique to open surgery in well-selected patients.« less

  12. Endovascular Management of Patients with Head and Neck Cancers Presenting with Acute Hemorrhage: A Single-Center Retrospective Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vilas Boas, P. P.; Castro-Afonso, L. H. de; Monsignore, L. M.

    PurposeAcute hemorrhage associated with cancers of the head and neck is a life-threatening condition that requires immediate action. The aim of this study was to assess the safety and efficacy of endovascular embolization for acute hemorrhage in patients with head and neck cancers.Materials and MethodsData were retrospectively collected from patients with head and neck cancers who underwent endovascular embolization to treat acute hemorrhage. The primary endpoint was the rate of immediate control of hemorrhage during the first 24 h after embolization. The secondary endpoints were technical or clinical complications, rate of re-hemorrhage 24 h after the procedure, time from embolization to re-hemorrhage,more » hospitalization time, mortality rate, and time from embolization to death.ResultsFifty-one patients underwent endovascular embolization. The primary endpoint was achieved in 94% of patients. The rate of technical complications was 5.8%, and no clinical complication was observed. Twelve patients (23.5%) had hemorrhage recurrence after an average time of 127.5 days. The average hospitalization time was 7.4 days, the mortality rate during the follow-up period was 66.6%, and the average time from embolization to death was 132.5 days.ConclusionEndovascular embolization to treat acute hemorrhage in patients with head and neck cancers is a safe and effective method for the immediate control of hemorrhage and results in a high rate of hemorrhage control. Larger studies are necessary to determine which treatment strategy is best for improving patient outcomes.« less

  13. De novo development of dural arteriovenous fistula after endovascular embolization of pial arteriovenous fistula.

    PubMed

    Paramasivam, Srinivasan; Toma, Naoki; Niimi, Yasunari; Berenstein, Alejandro

    2013-07-01

    The development of de novo dural arteriovenous fistula(s) following endovascular embolization of a prior high-flow pial arteriovenous fistula (PAVF) has not previously been reported and the natural history is unknown. The anatomic basis, pathophysiologic mechanism, management and outcome are discussed. Treatment-completed congenital PAVFs treated at our center between January 2005 and August 2011 were analyzed retrospectively. Among 16 cases of PAVFs treated by endovascular embolization, four developed de novo dural arteriovenous fistulas during treatment or on follow-up that were not present before treatment. Information was collected from the clinical case records, imaging by MRI on presentation and during follow-up, all angiographic images and records during each of the procedures and during follow-up. The time interval between the last embolization and identification of a dural fistula ranged from 3 to 14 months. Ten fistulas were identified in four patients, seven of which were embolized, four with glue, two with Onyx18 and one with absolute alcohol. None recanalized, while one patient developed fistula in an adjacent location that was subsequently treated with radiosurgery. Not all fistulas need treatment; small fistulas with a minimal flow can safely be observed. De novo dural fistulas following endovascular embolization of high-flow PAVFs is not an uncommon development. They are mostly asymptomatic and develop anywhere along the drainage of the fistula, maturing over time and diagnosed during follow-up studies, emphasizing the need for follow-up angiography. They can be effectively treated by endovascular embolization. Localized refractory dural fistulas can be dealt with by radiosurgery.

  14. Endovascular Therapy Research in Lower Limb Peripheral Arterial Disease Published Over a 5-Year Period: Who is Publishing and Where?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asadi, H.; Lee, R. J.; Sheehan, M.

    IntroductionPeripheral arterial disease (PAD) is being increasingly managed by endovascular therapies. In this study, we identified the clinical services publishing research as well as the journals of publication over a 5-year period.MethodsTwenty keywords and phrases related to endovascular intervention were identified, and a literature search was performed through the PubMed database from January 2009 to January 2014. Inclusion criteria were English language, study population more than five patients, and matching the keyword search. Eligible studies were collated into a database and classified by journal of publication, PubMed number, article title, publishing clinical service, type of publication, country of origin, andmore » authors.Results825 studies from 114 different journals were identified. 297 papers were excluded. Of the 528 included papers, 204 (39%) were published by Vascular Surgery (VS), 157 (30%) by Interventional Radiology (IR), 101 (19%) by Cardiology, 43 (8%) by Angiology, 6 (1%) by Vascular Medicine, and 17 (3%) from miscellaneous services. 283 (54%) studies originated from Europe, 157 (30%) from North America, 76 (14%) from Asia, 6 from Australia, 3 each from South America and Africa. IR published the most papers on PAD endovascular intervention in Europe with VS second while this trend was reversed in the USA. The 528 papers were published in 98 different journals with retrospective case series (72%), the majority.ConclusionIR continues to play a significant research role in endovascular intervention in PAD, particularly in Europe, and specifically in below the knee intervention, pedal intervention, and drug-eluting technologies.« less

  15. Treatment protocol based on assessment of clot quality during endovascular thrombectomy for acute ischemic stroke using the Trevo stent retriever

    PubMed Central

    Ishikawa, Kojiro; Ohshima, Tomotaka; Nishihori, Masahiro; Imai, Tasuku; Goto, Shunsaku; Yamamoto, Taiki; Nishizawa, Toshihisa; Shimato, Shinji; Kato, Kyozo

    2016-01-01

    ABSTRACT The optional endovascular approach for acute ischemic stroke is unclear. The Trevo stent retriever can be used as first-line treatment for fast mechanical recanalization. The authors developed a treatment protocol for acute ischemic stroke based on the assessment of clot quality during clot removal with the Trevo. This prospective single-center study included all patients admitted for acute ischemic stroke between July 2014 and February 2015, who underwent emergency endovascular treatment. According to the protocol, the Trevo was used for first-line treatment. Immediately after the Trevo was deployed, the stent delivery wire was pushed to open the stent by force (ACAPT technique). Clot quality was assessed on the basis of the perfusion status after deployment of the Trevo; continued occlusion or immediate reopening either reoccluded or maintained after the stent retriever had been in place for 5 min. If there was no obvious clot removal after the first pass with the Trevo, according to the quality of the clot, either a second pass was performed or another endovascular device was selected. Twelve consecutive patients with acute major cerebral artery occlusion were analyzed. Thrombolysis in cerebral infarction score 2b and 3 was achieved in 11 patients (91.7%) and 9 (75%) had a good clinical outcome after 90 days based on a modified Rankin scale score ≤ 2. Symptomatic intracranial hemorrhage occurred in 1 patient (8.3%). The overall mortality rate was 8.3%. Endovascular thrombectomy using the Trevo stent retriever for first-line treatment is feasible and effective. PMID:27578909

  16. [Endovascular treatment in acute ischaemic stroke. A stroke care plan for the region of Madrid].

    PubMed

    Alonso de Leciñana, M; Díaz-Guzmán, J; Egido, J A; García Pastor, A; Martínez-Sánchez, P; Vivancos, J; Díez-Tejedor, E

    2013-09-01

    Endovascular therapies (intra-arterial thrombolysis and mechanical thrombectomy) after acute ischaemic stroke are being implemented in the clinical setting even as they are still being researched. Since we lack sufficient data to establish accurate evidence-based recommendations for use of these treatments, we must develop clinical protocols based on current knowledge and carefully monitor all procedures. After review of the literature and holding work sessions to reach a consensus among experts, we developed a clinical protocol including indications and contraindications for endovascular therapies use in acute ischaemic stroke. The protocol includes methodology recommendations for diagnosing and selecting patients, performing revascularisation procedures, and for subsequent patient management. Its objective is to increase the likelihood of efficacy and treatment benefit and minimise risk of complications and ineffective recanalisation. Based on an analysis of healthcare needs and available resources, a cooperative inter-hospital care system has been developed. This helps to ensure availability of endovascular therapies to all patients, a fast response time, and a good cost-to-efficacy ratio. It includes also a prospective register which serves to monitor procedures in order to identify any opportunities for improvement. Implementation of endovascular techniques for treating acute ischaemic stroke requires the elaboration of evidence-based clinical protocols and the establishment of appropriate cooperative healthcare networks guaranteeing both the availability and the quality of these actions. Such procedures must be monitored in order to improve methodology. Copyright © 2012 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  17. Endovascular treatment of chronic cerebro spinal venous insufficiency in patients with multiple sclerosis modifies circulating markers of endothelial dysfunction and coagulation activation: a prospective study.

    PubMed

    Napolitano, Mariasanta; Bruno, Aldo; Mastrangelo, Diego; De Vizia, Marcella; Bernardo, Benedetto; Rosa, Buonagura; De Lucia, Domenico

    2014-10-01

    We performed a monocentric observational prospective study to evaluate coagulation activation and endothelial dysfunction parameters in patients with multiple sclerosis undergoing endovascular treatment for cerebro-spinal-venous insufficiency. Between February 2011 and July 2012, 144 endovascular procedures in 110 patients with multiple sclerosis and chronical cerebro-spinal venous insufficiency were performed and they were prospectively analyzed. Each patient was included in the study according to previously published criteria, assessed by the investigators before enrollment. Endothelial dysfunction and coagulation activation parameters were determined before the procedure and during follow-up at 1, 3, 6, 9, 12, 15 and 18 months after treatment, respectively. After the endovascular procedure, patients were treated with standard therapies, with the addition of mesoglycan. Fifty-five percent of patients experienced a favorable outcome of multiple sclerosis within 1 month after treatment, 25% regressed in the following 3 months, 24.9% did not experience any benefit. In only 0.1% patients, acute recurrence was observed and it was treated with high-dose immunosuppressive therapy. No major complications were observed. Coagulation activation and endothelial dysfunction parameters were shown to be reduced at 1 month and stable up to 12-month follow-up, and they were furthermore associated with a good clinical outcome. Endovascular procedures performed by a qualified staff are well tolerated; they can be associated with other currently adopted treatments. Correlations between inflammation, coagulation activation and neurodegenerative disorders are here supported by the observed variations in plasma levels of markers of coagulation activation and endothelial dysfunction.

  18. Endovascular Treatment of Cerebral Aneurysms in Relation to Their Parent Artery Wall: A Single Center Study

    PubMed Central

    Mitsos, A.P.; Giannakopoulou, M.D.; Kaklamanos, I.G.; Kapritsou, M.; Konstantinou, M.I.; Fotis, T.; Mamoura, K.V.; Mariolis-Sapsakos, T.; Ntountas, I.T.; Konstantinou, E.A.

    2013-01-01

    We report our two-year experience in the endovascular treatment of brain aneurysms in relation to their parent artery wall. We prospectively recorded patients with intracranial aneurysms (107 ruptured - 38 unruptured) treated with coiling during a two-year period: 145 patients, 94 females and 51 males - mean age 56 years. The aneurysms were divided into side-wall (A) and bifurcation (B) groups. A total occlusion rate was noted in post-embolization angiograms in 101 aneurysms (70%) with a morbidity of 4%. No angiographic recurrence arose in the six-month follow-up. The two groups had a similar total occlusion rate (68.31% and 71.8% respectively), while the complication rate was 3% in group A and 4.7% in group B. Significant differences between the two groups were noted in the number of assisted coiling cases: 28 out of 60 cases (46.7%) in group A - 14 out of 85 cases (16.5%) in group B. Further statistical analysis showed strong dependencies for the type of endovascular procedure between the ruptured and unruptured aneurysms in both groups (p 0.000<0.05), but no dependencies between the aneurysm occlusion rate and the ruptured or non-ruptured aneurysms, or between the occlusion rate and the type of endovascular procedure (p 0.552 >0.05 and 0.071 >0.05 respectively). In conclusion, the anatomic relation of the aneurysm sac with the wall of the parent artery is important, as significant differences in endovascular practice, devices and techniques were noted between side-wall and bifurcation aneurysms. PMID:23859171

  19. Stratification of Recanalization for Patients with Endovascular Treatment of Intracranial Aneurysms

    PubMed Central

    Ogilvy, Christopher S.; Chua, Michelle H.; Fusco, Matthew R.; Reddy, Arra S.; Thomas, Ajith J.

    2015-01-01

    Background With increasing utilization of endovascular techniques in the treatment of both ruptured and unruptured intracranial aneurysms, the issue of obliteration efficacy has become increasingly important. Objective Our goal was to systematically develop a comprehensive model for predicting retreatment with various types of endovascular treatment. Methods We retrospectively reviewed medical records that were prospectively collected for 305 patients who received endovascular treatment for intracranial aneurysms from 2007 to 2013. Multivariable logistic regression was performed on candidate predictors identified by univariable screening analysis to detect independent predictors of retreatment. A composite risk score was constructed based on the proportional contribution of independent predictors in the multivariable model. Results Size (>10 mm), aneurysm rupture, stent assistance, and post-treatment degree of aneurysm occlusion were independently associated with retreatment while intraluminal thrombosis and flow diversion demonstrated a trend towards retreatment. The Aneurysm Recanalization Stratification Scale was constructed by assigning the following weights to statistically and clinically significant predictors. Aneurysm-specific factors: Size (>10 mm), 2 points; rupture, 2 points; presence of thrombus, 2 points. Treatment-related factors: Stent assistance, -1 point; flow diversion, -2 points; Raymond Roy 2 occlusion, 1 point; Raymond Roy 3 occlusion, 2 points. This scale demonstrated good discrimination with a C-statistic of 0.799. Conclusion Surgical decision-making and patient-centered informed consent require comprehensive and accessible information on treatment efficacy. We have constructed the Aneurysm Recanalization Stratification Scale to enhance this decision-making process. This is the first comprehensive model that has been developed to quantitatively predict the risk of retreatment following endovascular therapy. PMID:25621984

  20. Plasma Processes of Cutting and Welding

    DTIC Science & Technology

    1976-02-01

    TIG process. 2.2.2 Keyhole Welding In plasma arc welding , the term...Cutting 3 3 4 4 4 2.2 Plasma Arc Welding 5 2.2.1 Needle Arc Welding 2.2.2 Keyhole Welding 5 6 3. Applications 8 93.1 Economics 4. Environmental Aspects of...Arc Lengths III. Needle Arc Welding Conditions IV. Keyhole Welding Conditions v. Chemical Analyses of Plates Used - vii - 1. 2. 3. 4. 5. 6. 7. 8.

  1. Quality status display for a vibration welding process

    DOEpatents

    Spicer, John Patrick; Abell, Jeffrey A.; Wincek, Michael Anthony; Chakraborty, Debejyo; Bracey, Jennifer; Wang, Hui; Tavora, Peter W.; Davis, Jeffrey S.; Hutchinson, Daniel C.; Reardon, Ronald L.; Utz, Shawn

    2017-03-28

    A system includes a host machine and a status projector. The host machine is in electrical communication with a collection of sensors and with a welding controller that generates control signals for controlling the welding horn. The host machine is configured to execute a method to thereby process the sensory and control signals, as well as predict a quality status of a weld that is formed using the welding horn, including identifying any suspect welds. The host machine then activates the status projector to illuminate the suspect welds. This may occur directly on the welds using a laser projector, or on a surface of the work piece in proximity to the welds. The system and method may be used in the ultrasonic welding of battery tabs of a multi-cell battery pack in a particular embodiment. The welding horn and welding controller may also be part of the system.

  2. Influence of the Gap Width on the Geometry of the Welded Joint in Hybrid Laser-Arc Welding

    NASA Astrophysics Data System (ADS)

    Turichin, G.; Tsibulskiy, I.; Kuznetsov, M.; Akhmetov, A.; Mildebrath, M.; Hassel, T.

    The aim of this research was the experimental investigation of the influence of the gap width and speed of the welding wire on the changes of the geometry in the welded joint in the hybrid laser-arc welding of shipbuilding steel RS E36. The research was divided into three parts. First, in order to understand the influence of the gap width on the welded joint geometry, experimental research was done using continuous wave fiber laser IPG YLS-15000 with arc rectifier VDU-1500DC. The second part involved study of the geometry of the welded joint and hardness test results. Three macrosections from each welded joint were obtained. Influence of the gap width and welding wire speed on the welded joint geometry was researched in the three lines: in the right side of the plates, middle welded joint and in the root welded joint.

  3. The effects of welded joint characteristics on its properties in HDPE thermal fusion welding

    NASA Astrophysics Data System (ADS)

    Dai, Hongbin; Peng, Jun

    2017-05-01

    In this paper, PE100 pipes with the diameter of 200 mm and the thickness of 11.9 mm were used as material. The welded joints were obtained in different welding pressures with the optimal welding temperature of 220∘C. Reheating process on the welded joints with the temperature of 130∘C was carried out. The joints exhibited X-type, and the cause of X-type joints was discussed. The temperature field in the forming process of welded joints was measured, and tensile and bending tests on welded joints were carried out. The fracture surface of welded joints was observed by scanning electron microscopy (SEM), and crystallinity calculation was taken by X-ray diffraction (XRD). The mechanism of X-type weld profile effects on welded joints properties was analyzed. It was concluded that the mechanical properties of welded joints decrease with the reduced X distance between lines.

  4. Multi-mode ultrasonic welding control and optimization

    DOEpatents

    Tang, Jason C.H.; Cai, Wayne W

    2013-05-28

    A system and method for providing multi-mode control of an ultrasonic welding system. In one embodiment, the control modes include the energy of the weld, the time of the welding process and the compression displacement of the parts being welded during the welding process. The method includes providing thresholds for each of the modes, and terminating the welding process after the threshold for each mode has been reached, the threshold for more than one mode has been reached or the threshold for one of the modes has been reached. The welding control can be either open-loop or closed-loop, where the open-loop process provides the mode thresholds and once one or more of those thresholds is reached the welding process is terminated. The closed-loop control provides feedback of the weld energy and/or the compression displacement so that the weld power and/or weld pressure can be increased or decreased accordingly.

  5. Optimization and Prediction of Angular Distortion and Weldment Characteristics of TIG Square Butt Joints

    NASA Astrophysics Data System (ADS)

    Narang, H. K.; Mahapatra, M. M.; Jha, P. K.; Biswas, P.

    2014-05-01

    Autogenous arc welds with minimum upper weld bead depression and lower weld bead bulging are desired as such welds do not require a second welding pass for filling up the upper bead depressions (UBDs) and characterized with minimum angular distortion. The present paper describes optimization and prediction of angular distortion and weldment characteristics such as upper weld bead depression and lower weld bead bulging of TIG-welded structural steel square butt joints. Full factorial design of experiment was utilized for selecting the combinations of welding process parameter to produce the square butts. A mathematical model was developed to establish the relationship between TIG welding process parameters and responses such as upper bead width, lower bead width, UBD, lower bead height (bulging), weld cross-sectional area, and angular distortions. The optimal welding condition to minimize UBD and lower bead bulging of the TIG butt joints was identified.

  6. Creep rupture strength of activated-TIG welded 316L(N) stainless steel

    NASA Astrophysics Data System (ADS)

    Sakthivel, T.; Vasudevan, M.; Laha, K.; Parameswaran, P.; Chandravathi, K. S.; Mathew, M. D.; Bhaduri, A. K.

    2011-06-01

    316L(N) stainless steel plates were joined using activated-tungsten inert gas (A-TIG) welding and conventional TIG welding process. Creep rupture behavior of 316L(N) base metal, and weld joints made by A-TIG and conventional TIG welding process were investigated at 923 K over a stress range of 160-280 MPa. Creep test results showed that the enhancement in creep rupture strength of weld joint fabricated by A-TIG welding process over conventional TIG welding process. Both the weld joints fractured in the weld metal. Microstructural observation showed lower δ-ferrite content, alignment of columnar grain with δ-ferrite along applied stress direction and less strength disparity between columnar and equiaxed grains of weld metal in A-TIG joint than in MP-TIG joint. These had been attributed to initiate less creep cavitation in weld metal of A-TIG joint leading to improvement in creep rupture strength.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stine, Andrew Martin; Pierce, Stanley W.; Moniz, Paul F.

    The welding equipment used for welding iridium containers (clads) at Los Alamos National Laboratory is twenty five years old and is undergoing an upgrade. With the upgrade, there is a requirement for requalification of the welding process, and the opportunity for process improvement. Testing of the new system and requalification will require several welds on iridium test parts and clads, and any efforts to improve the process will add to the need for iridium parts. The extreme high cost of iridium imposes a severe limitation on the extent of test welding that can be done. The 2 inch diameter, 0.027more » inch thick, iridium blank disc that the clad cup is formed from, is useful for initial weld trials, but it costs $5000. The development clad sets needed for final tests and requalification cost $15,000 per set. A solution to iridium cost issue would be to do the majority of the weld development on a less expensive surrogate metal with similar weld characteristics. One such metal is molybdenum. Since its melting index (melting temperature x thermal conductivity) is closest to iridium, welds on molybdenum should be similar in size for a given weld power level. Molybdenum is inexpensive; a single 2 inch molybdenum disc costs only $9. In order to evaluate molybdenum as a surrogate for iridium, GTA welds were first developed to provide full penetration on 0.030 inch thick molybdenum discs at speeds of 20, 25, and 30 inches per minute (ipm). These weld parameters were then repeated on the standard 0.027 inch thick iridium blanks. The top surface and bottom surface (root) width and grain structure of the molybdenum and iridium welds were compared, and similarities were evident between the two metals. Due to material and thickness differences, the iridium welds were approximately 35% wider than the molybdenum welds. A reduction in iridium weld current of 35% produce welds slightly smaller than the molybdenum welds yet showed that current could be scaled according to molybdenum/iridium weld width ratio to achieve similar welds. Further weld trials using various thicknesses of molybdenum determined that 0.024 inch thick molybdenum material would best match the 0.027 inch thick iridium in achieving comparable welds when using the same welding parameters. Across the range of welding speeds, the characteristic weld pool shape and solidification grain structure in the two materials was also similar. With the similarity of welding characteristics confirmed, and the appropriate thickness of molybdenum determined, it has been concluded that the use of molybdenum discs and tube sections will greatly expand the weld testing opportunities prior to iridium weld qualification« less

  8. Development of an intelligent system for cooling rate and fill control in GMAW. [Gas Metal Arc Welding (GMAW)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Einerson, C.J.; Smartt, H.B.; Johnson, J.A.

    1992-01-01

    A control strategy for gas metal arc welding (GMAW) is developed in which the welding system detects certain existing conditions and adjusts the process in accordance to pre-specified rules. This strategy is used to control the reinforcement and weld bead centerline cooling rate during welding. Relationships between heat and mass transfer rates to the base metal and the required electrode speed and welding speed for specific open circuit voltages are taught to a artificial neural network. Control rules are programmed into a fuzzy logic system. TRADITOINAL CONTROL OF THE GMAW PROCESS is based on the use of explicit welding proceduresmore » detailing allowable parameter ranges on a pass by pass basis for a given weld. The present work is an exploration of a completely different approach to welding control. In this work the objectives are to produce welds having desired weld bead reinforcements while maintaining the weld bead centerline cooling rate at preselected values. The need for this specific control is related to fabrication requirements for specific types of pressure vessels. The control strategy involves measuring weld joint transverse cross-sectional area ahead of the welding torch and the weld bead centerline cooling rate behind the weld pool, both by means of video (2), calculating the required process parameters necessary to obtain the needed heat and mass transfer rates (in appropriate dimensions) by means of an artificial neural network, and controlling the heat transfer rate by means of a fuzzy logic controller (3). The result is a welding machine that senses the welding conditions and responds to those conditions on the basis of logical rules, as opposed to producing a weld based on a specific procedure.« less

  9. [Study on the arc spectral information for welding quality diagnosis].

    PubMed

    Li, Zhi-Yong; Gu, Xiao-Yan; Li, Huan; Yang, Li-Jun

    2009-03-01

    Through collecting the spectral signals of TIG and MIG welding arc with spectrometer, the arc light radiations were analyzed based on the basic theory of plasma physics. The radiation of welding arc distributes over a broad range of frequency, from infrared to ultraviolet. The arc spectrum is composed of line spectra and continuous spectra. Due to the variation of metal density in the welding arc, there is great difference between the welding arc spectra of TIG and MIG in both their intensity and distribution. The MIG welding arc provides more line spectra of metal and the intensity of radiation is greater than TIG. The arc spectrum of TIG welding is stable during the welding process, disturbance factors that cause the spectral variations can be reflected by the spectral line related to the corresponding element entering the welding arc. The arc spectrum of MIG welding will fluctuate severely due to droplet transfer, which produces "noise" in the line spectrum aggregation zone. So for MIG welding, the spectral zone lacking spectral line is suitable for welding quality diagnosis. According to the characteristic of TIG and MIG, special spectral zones were selected for welding quality diagnosis. For TIG welding, the selected zone is in ultraviolet zone (230-300 nm). For MIG welding, the selected zone is in visible zone (570-590 nm). With the basic theory provided for welding quality diagnosis, the integral intensity of spectral signal in the selected zone of welding process with disturbing factor was studied to prove the theory. The results show that the welding quality and disturbance factors can be diagnosed with good signal to noise ratio in the selected spectral zone compared with signal in other spectral zone. The spectral signal can be used for real-time diagnosis of the welding quality.

  10. A Study to Increase Weld Penetration in P91 Steel During TIG Welding by using Activating Fluxes

    NASA Astrophysics Data System (ADS)

    Singh, Akhilesh Kumar; Kumar, Mayank; Dey, Vidyut; Naresh Rai, Ram

    2017-08-01

    Activated Flux TIG (ATIG) welding is a unique joining process, invented at Paton Institute of electric welding in 1960. ATIG welding process is also known as flux zoned TIG (FZTIG). In this process, a thin layer of activating flux is applied along the line on the surface of the material where the welding is to be carries out. The ATIG process aids to increase the weld penetration in thick materials. Activating fluxes used in the literature show the use of oxides like TiO2, SiO2, Cr2O3, ZnO, CaO, Fe2O3, and MnO2 during welding of steels. In the present study, ATIG was carried out on P-91 steel. Though, Tungsten Inert Gas welding gives excellent quality welds, but the penetration obtained in such welding is still demanding. P91 steel which is ferritic steel is used in high temperature applications. As this steel is, generally, used in thick sections, fabrication of such structures with TIG welding is limited, due to its low depth of penetration. To increase the depth of penetration in P91while welding with ATIG, the role of various oxides were investigated. Apart from the oxides mentioned above, in the present study the role of B2O3, V2O5 and MgO, during ATIG welding of P91 was investigated. It was seen that, compared to TIG welding, there was phenomenal increase in weld penetration during ATIG welding. Amongst all the oxides used in this study, maximum penetration was achieved in case of B2O3. The measurements of weld penetration, bead width and heat affected zone of the weldings were carried out using an image analysis technique.

  11. Endovascular repair of multiple infrageniculate aneurysms in a patient with vascular type Ehlers-Danlos syndrome.

    PubMed

    Domenick, Natalie; Cho, Jae S; Abu Hamad, Ghassan; Makaroun, Michel S; Chaer, Rabih A

    2011-09-01

    Patients with vascular type Ehler-Danlos syndrome can develop aneurysms in unusual locations. We describe the case of a 33-year-old woman with vascular type Ehlers-Danlos syndrome who developed metachronous tibial artery aneurysms that were sequentially treated with endovascular means. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  12. Clamp force and alignment checking device

    DOEpatents

    Spicer, John Patrick; Cai, Wayne W.; Chakraborty, Debejyo; Mink, Keith

    2017-04-11

    A check fixture measures a total clamp force applied by a welder device. The welder device includes a welding horn having a plurality of weld pads and welding anvil having a plurality of weld pads. The check fixture includes a base member operatively supporting a plurality of force sensors. The base member and the force sensors are received between the weld pads of the welding horn and the anvil pads of the welding anvil. Each force sensor is configured to measure an individual clamp force applied thereto by corresponding weld and anvil pads when the base member is received between the welding horn and the welding anvil and the welder device is in the clamped position. The individual clamp forces are used to determine whether the weld and/or anvil pads are worn or misaligned.

  13. Drug coated balloon in peripheral artery disease.

    PubMed

    Shanmugasundaram, Madhan; Murugapandian, Sangeetha; Truong, Huu Tam; Lotun, Kapildeo; Banerjee, Subhash

    2018-04-21

    Peripheral artery disease (PAD) is highly prevalent but is often underdiagnosed and undertreated. Lower extremity PAD can often be life style limiting. Revascularization in carefully selected lower extremity PAD patients improves symptoms and functional status. Surgical revascularization used to be the only available strategy, but in the recent years, endovascular strategies have gained popularity due to faster recovery times with low morbidity and mortality rates. Endovascular procedures have increased significantly in the United States in the past few years. That being said, higher restenosis rates and low long-term patency rates have been the limiting factors for this strategy. Drug eluting stents have been introduced to help with lowering restenosis, however lower extremity PAD involves long segment where the outcomes of stents are suboptimal. Also, the disease often crosses joint line that makes it less ideal for the stents. Drug coated balloons (DCB) have been introduced to improve patency rates following endovascular intervention for lower extremity PAD. They have gained popularity among endovascular specialists due to its ease of use and the concept of "leave nothing behind". This is a review of scientific evidence supporting DCB use in PAD. Published by Elsevier Inc.

  14. [Management of traumatic aortic rupture. About 37 cases].

    PubMed

    Denguir, R; Frikha, I; Kaouel, K; Abdennadher, M; Ziadi, J; Jemel, A; Ben Mrad, M; Kallel, S; Derbel, B; Gueldiche, M; Ghédira, F; Mlaïhi, S; Masmoudi, S; Kalfat, T; Menif, J; Ben Omrane, S; Karoui, A; Khayati, A

    2013-02-01

    The aim of this study was to review our experience in the management of traumatic rupture of the aortic isthmus, to evaluate the results of surgery and endovascular exclusion and to develop an adequate therapeutic strategy based on the existence and severity of associated injuries. A series of 37 patients presenting posttraumatic aortic rupture associated with other severe lesions was collected from 2000 to 2012. There were 33 males and four females, mean age 38 years. In this series, 25 patients underwent surgical treatment and 12 endovascular exclusion. Six patients died during or after surgery. Overall mortality was 16% (24% in the surgery group). The postoperative period was uneventful in all patients treated with the endovascular procedure. Postoperative computed tomography controls at one week, 1 month and 12 months showed good positioning of the stent without endoleakage. Traumatic aortic rupture is often the result of a severe high-energy chest trauma. Other serious injuries are often associated. Results of immediate surgical repair are associated with high morbidity and mortality. The advent of endovascular treatment has revolutionized the treatment of traumatic aortic rupture, especially in patients with a high surgical risk. Copyright © 2013. Published by Elsevier Masson SAS.

  15. Portal Vein Stenting Combined with Iodine-125 Seeds Endovascular Implantation Followed by Transcatheter Arterial Chemoembolization for Treatment of Hepatocellular Carcinoma Patients with Portal Vein Tumor Thrombus

    PubMed Central

    Zhou, Tanyang; Zhu, Tongyin; Zhang, Yuelin; Nie, Chunhui; Ai, Jing; Zhou, Guanhui; Zhang, Aibin; Dong, Meng-Jie; Wang, Wei-Lin

    2016-01-01

    Aim was to assess the therapeutic value of portal vein stenting (PVS) combined with iodine-125 seed (125I seed) strand endovascular implantation followed by transcatheter arterial chemoembolization (TACE) for treating patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombus (PVTT). This was a retrospective study of 34 patients aged 29–81 years, diagnosed HCC with PVTT, and treated with PVS combined with 125I seed strand endovascular implantation followed by TACE between January 2012 and August 2014. Survival, stent patency, technical success rate, complications related to the procedure, and adverse events were recorded. The technical success rate was 100%. No serious procedure-related adverse event was recorded. The median survival was 147 days. The cumulative survival rates and stent patency rates at 90, 180, and 360 days were 94.1%, 61.8%, and 32.4% and 97.1% (33/34), 76.9% (24/34), and 29.4% (10/34), respectively. PVS combined with 125I seed strand endovascular implantation followed by TACE is feasible for patients with HCC and PVTT. It resulted in appropriate survival and stent patency, with no procedure-related adverse effects. PMID:27999793

  16. Endovascular approach to treat ascending aortic pseudoaneurysm in a patient with previous CABG and very high surgical risk.

    PubMed

    Zago, Alexandre C; Saadi, Eduardo K; Zago, Alcides J

    2011-10-01

    Pseudoaneurysm of the ascending aorta is an uncommon pathology and a challenge in high-risk patients who undergo conventional surgery because of high operative morbidity and mortality. Endovascular exclusion of an aortic pseudoaneurysm using an endoprosthesis is a less invasive approach, but few such cases have been reported. Moreover, the use of this approach poses unique therapeutic challenges because there is no specific endoprosthesis for ascending aortic repair, particularly to treat patients with previous coronary artery bypass graft (CABG). We describe the case of a 74-year-old patient who had undergone CABG and later presented with an iatrogenic ascending aortic pseudoaneurysm that occurred during an angiography. This patient was at very high risk for surgical treatment and, therefore, an endovascular approach was adopted: percutaneous coronary intervention for the left main coronary artery, left anterior descending and left circumflex native coronary arteries followed by endovascular endoprosthesis deployment in the ascending aorta to exclude the pseudoaneurysm. Both procedures were successfully performed, and the patient was discharged without complications 4 days later. At 5 months' clinical follow-up, his clinical condition was good and he had no complications. Copyright © 2011 Wiley-Liss, Inc.

  17. Canadian Cardiovascular Society/Canadian Society of Cardiac Surgeons/Canadian Society for Vascular Surgery Joint Position Statement on Open and Endovascular Surgery for Thoracic Aortic Disease.

    PubMed

    Appoo, Jehangir J; Bozinovski, John; Chu, Michael W A; El-Hamamsy, Ismail; Forbes, Thomas L; Moon, Michael; Ouzounian, Maral; Peterson, Mark D; Tittley, Jacques; Boodhwani, Munir

    2016-06-01

    In 2014, the Canadian Cardiovascular Society (CCS) published a position statement on the management of thoracic aortic disease addressing size thresholds for surgery, imaging modalities, medical therapy, and genetics. It did not address issues related to surgical intervention. This joint Position Statement on behalf of the CCS, Canadian Society of Cardiac Surgeons, and the Canadian Society for Vascular Surgery provides recommendations about thoracic aortic disease interventions, including: aortic valve repair, perfusion strategies for arch repair, extended arch hybrid reconstruction for acute type A dissection, endovascular management of arch and descending aortic aneurysms, and type B dissection. The position statement is constructed using Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology, and has been approved by the primary panel, an international secondary panel, and the CCS Guidelines Committee. Advent of endovascular technology has improved aortic surgery safety and extended the indications of minimally invasive thoracic aortic surgery. The combination of safer open surgery with endovascular treatment has improved patient outcomes in this rapidly evolving subspecialty field of cardiovascular surgery. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  18. Effect of Endovascular Interventions on General Surgery Trainee Operative Experience; a Comparison of Case Log Reports.

    PubMed

    Pedersen, Rose C; Li, Yiping; Chang, Jason S; Lew, Wesley K; Patel, Kaushal Kevin

    2016-05-01

    Vascular surgery fellowship training has evolved with the widespread adoption of endovascular interventions. The purpose of this study is to examine how general surgery trainee exposure to vascular surgery has changed over time. Review of the Accreditation Council for Graduate Medical Education national case log reports for graduating Vascular Surgery Fellows (VF), and general surgery residents (GSR) from 2001 to 2012 was performed. The number of GSR increased from 1021 to 1098, and the number of VF increased from 96 to 121 from 2001 to 2012. The total number of vascular cases done by VF increased by 1161 since 2001 (298-762), whereas the total number of vascular cases done by GSR has decreased by 40% during this time period (186-116). Vascular fellows increase was due primarily to an increase in endovascular experience; a finding not noted in general surgery residents. Vascular fellow case log changes are due primarily to an increase in endovascular experience that has not been mirrored by general surgery trainees. Open surgery experience has decreased overall for general surgery residents in all major categories, a change not seen in vascular surgery fellows. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. A novel experimental animal model of arterial stenosis based on endovascular radiofrequency energy application.

    PubMed

    Lazoura, Olga; Zacharoulis, Dimitris; Kanavou, Theodora; Rountas, Christos; Katsimboulas, Michael; Tzovaras, George; Habib, Nagy

    2011-01-01

    To develop a new rabbit model of arterial stenosis using endovascular radiofrequency (RF) energy. Ten rabbits were used for multiple endovascular RF applications to the aorta and left common carotid artery through the Habib™ VesCoag™ catheter. Angiography and color Doppler ultrasound were used to assess vessel patency immediately following the procedure and six weeks later. One rabbit was sacrificed following the procedure for histopathologic analysis of the vessel wall. Two rabbits died of aortic and carotid rupture, respectively, immediately after the procedure. The remaining seven rabbits were sacrificed after six-week follow-up for histopathological analysis. Optimal RF generator settings to induce significant arterial stenosis (>50%) without complications were standardized at 24-26 watts (W) for 1.5 min for the aorta and 6 W for 1 min for the common carotid artery. The six-week follow-up showed permanent results in all surviving rabbits. Histopathology revealed intima and medial smooth muscle layer necrosis. We have developed a novel rabbit model of arterial stenosis using endovascular RF energy. Our model is fast, safe, inexpensive, and reproducible. It would be useful for experimental investigations and new therapeutic devices.

  20. Impact of polymer structure and composition on fully resorbable endovascular scaffold performance

    PubMed Central

    Ferdous, Jahid; Kolachalama, Vijaya B.; Shazly, Tarek

    2014-01-01

    Fully erodible endovascular scaffolds are being increasingly considered for the treatment of obstructive arterial disease owing to their potential to mitigate long-term risks associated with permanent alternatives. While complete scaffold erosion facilitates vessel healing, generation and release of material degradation by-products from candidate materials such as poly-l-lactide (PLLA) may elicit local inflammatory responses that limit implant efficacy. We developed a computational framework to quantify how the compositional and structural parameters of PLLA-based fully erodible endovascular scaffolds affect degradation kinetics, erosion kinetics and the transient accumulation of material by-products within the arterial wall. Parametric studies reveal that, while some material properties have similar effects on these critical processes, others induce qualitatively opposing responses. For example, scaffold degradation is only mildly responsive to changes in either PLLA polydispersity or the initial degree of crystallinity, while the erosion kinetics is comparatively sensitive to crystallinity. Moreover, lactide doping can effectively tune both scaffold degradation and erosion, but a concomitant increase in local byproduct accumulation raises concerns about implant safety. Optimized erodible endovascular scaffolds must precisely balance therapeutic function and biological response over the implant lifetime, where compositional and structural parameters will have differential effects on implant performance. PMID:23261926

  1. [Neurologist and emergency neuroendovascular revascularization -training programs for endovascular procedures-].

    PubMed

    Imai, Keisuke; Hamanaka, Masashi; Yamada, Takehiro; Yamazaki, Hidekazu; Yamamoto, Atsushi; Tsuto, Kazuma; Takegami, Tetsuro; Umezawa, Kunihiko; Ikeda, Eito; Mizuno, Toshiki

    2014-01-01

    Emergency neuroendovascular revascularization is a reperfusion therapy for acute stroke. The operator for this therapy has to obtain a license as a specialist in endovascular procedures. For neurologists wishing to acquire this license, there are two kinds of training programs: full-time training and concurrent training. Full-time training was chosen by the first author of this review, while concurrent training will be performed by staff in the author's department. The advantage of full-time training is the acquisition of a lot of experience of various diseases that are treated with endovascular procedures and managed in the periprocedural period. However, full-time training has the disadvantages of a requirement to discontinue medical care of neurological diseases except for stroke and employment at a remote institution. The advantages and disadvantages of concurrent training are the reverse of those of full-time training. Neither training system can succeed without cooperation from Departments of Neurology in neighboring universities and the institutional Department of Neurosurgery. It is particularly important for each neurologist to establish a goal of becoming an operator for recanalization therapy alone or for all fields of endovascular procedures because training will differ for attainment of each operator's goal.

  2. Intraoperative Transpedicular Onyx Injection to Reduce Vascularity of a Thoracic Hemangiopericytoma After Unsuccessful Preoperative Endovascular Embolization: a Technical Report.

    PubMed

    Mashaly, Hazem; Zhang, Zoe; Shaw, Andrew; Youssef, Patrick; Mendel, Ehud

    2018-02-01

    Hemangiopericytoma is a rare vascular tumor with central nervous system involvement representing only 1% of central nervous system tumors. They rarely affect the vertebral column. Complete surgical resection is the treatment of choice for hemangiopericytoma given their high rates of local recurrence. However, the high vascularity of such tumors with the risk of massive bleeding during surgery represents a significant challenge to surgeons. Therefore, preoperative endovascular embolization via the transarterial route has been advocated. In the current study, we present a case of a T12 hemangiopericytoma that was managed by a 2-stage surgical resection, with the use of intraoperative transpedicular onyx injection to reduce intraoperative blood loss following an unsuccessful trial of preoperative endovascular embolization. Preoperative endovascular embolization is not feasible in some cases due to the location of the segmental or radiculomedullary arteries in relation to tumor feeders and, rarely, small size of these arterial feeders. Percutaneous injection of onyx is an option. In this case report, we discuss direct intraoperative injection via a transpedicular route as a safe and effective method for decreasing the vascularity of some lesions and improving intraoperative blood loss. Copyright © 2017 by the Congress of Neurological Surgeons

  3. Endovascular recanalization of a port catheter-associated superior vena cava syndrome.

    PubMed

    Tonak, Julia; Fetscher, Sebastian; Barkhausen, Jörg; Goltz, Jan Peter

    2015-01-01

    Superior vena cava (SVC) syndrome owing to benign etiology is rare and endovascular techniques have been advocated as the treatment of choice. We report a case of endovascular revascularization of a port catheter-associated complete occlusion of the SVC with reversed flow in the azygos vein. In this setting using a sheath in combination with its dilatator to pass the occlusion of the SVC after neither a diagnostic catheter nor a PTA balloon would pass the lesion may be a valid option. A dual venous approach was established using the right common femoral vein and an indwelling port catheter in the right cephalic vein to dilate and stent the lesion. Finally, a port may be implanted after the revascularization had been successful. Passage through the port catheter-associated occlusion of the SVC was only possible by use of the sheath in combination with its dilatator. A dual venous access by the femoral approach and the indwelling central catheter is helpful in treating a SVC occlusion. Long-term central venous catheters may cause SVC syndrome, especially with a catheter tip located too far cranially. An endovascular revascularization of a complete occlusion of the SVC represents the therapy of choice.

  4. Automated GMA welding of austenitic stainless steel pipe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tahash, G.J.

    1996-12-31

    The study focused on reducing weld cycle times of rotatable subassemblies (spools) using automated welding equipment. A unique automatic Gas Metal Arc Welding (GMAW) system was used to produce a series of pipe to pipe welds on 141 mm (5 in.) schedule 80 seamless stainless steel pipe. After manual tack welding, the adaptive control system welded the root pass of the argon gas backed open vee groove circumferential butt joints in the IG rotated position with short circuiting transfer GMAW. The fill and cover passes were welded automatically with spray transfer GMAW. Automatic welding cycle times were found to bemore » 50--80 percent shorter than the current techniques of roll welding with Shielded Metal Arc Welding and manual Gas Tungsten Arc Welding. Weld costs ({Brit_pounds}/m), including amortization, for the various systems were compared. The cost of automated GMA welds was virtually equivalent to the most competitive methods while depositing 75% more filler metal per year. Also investigated were metallurgical effects generated by weld thermal cycling, and the associated effects on mechanical properties of the weld joint. Mechanical properties of the welds met or exceeded those of the base metal. Sensitization of the pipe did not occur in the heat affected zone (HAZ), based on the absence of evidence of intergranular attack in modified Strauss corrosion tests and despite the fact of interpass temperatures well above recommended maximums. Cooling rates of 3--5 C/s in the heat affected zone of the four pass welds were measured by thermocouple technique and found to be within the non-sensitizing range for this alloy.« less

  5. 49 CFR 195.230 - Welds: Repair or removal of defects.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired... welding procedure used to make the original weld are met upon completion of the final weld repair. [Amdt...

  6. 49 CFR 195.230 - Welds: Repair or removal of defects.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired... welding procedure used to make the original weld are met upon completion of the final weld repair. [Amdt...

  7. 49 CFR 195.230 - Welds: Repair or removal of defects.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired... welding procedure used to make the original weld are met upon completion of the final weld repair. [Amdt...

  8. 49 CFR 195.230 - Welds: Repair or removal of defects.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired... welding procedure used to make the original weld are met upon completion of the final weld repair. [Amdt...

  9. 49 CFR 195.230 - Welds: Repair or removal of defects.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired... welding procedure used to make the original weld are met upon completion of the final weld repair. [Amdt...

  10. Tailor-welded blanks and their production

    NASA Astrophysics Data System (ADS)

    Yan, Qi

    2005-01-01

    Tailor welded blanks had been widely used in the automobile industry. A tailor welded blank consists of several flat sheets that were laser welded together before stamping. A combination of different materials, thickness, and coatings could be welded together to form a blank for stamping car body panels. As for the material for automobile industry, this technology was one of the development trend for automobile industry because of its weight reduction, safety improvement and economical use of materials. In this paper, the characters and production of tailor welded blanks in the market were discussed in detail. There had two major methods to produce tailor welded blanks. Laser welding would replace mesh seam welding for the production of tailor welded blanks in the future. The requirements on the edge preparation of unwelded blanks for tailor welded blanks were higher than the other steel processing technology. In order to produce the laser welded blank, there had the other process before the laser welding in the factory. In the world, there had three kinds of patterns for the large volume production of tailor welded blanks. In China, steel factory played the important role in the promotion of the application of tailor welded blanks. The competition for the supply of tailor welded blanks to the automobile industry would become fierce in the near future. As a result, the demand for the quality control on the production of tailor welded blanks would be the first priority concern for the factory.

  11. Weld pool oscillation during pulsed GTA welding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aendenroomer, A.J.R.; Ouden, G. den

    1996-12-31

    This paper deals with weld pool oscillation during pulsed GTA welding and with the possibility to use this oscillation for in-process control of weld penetration. Welding experiments were carried out under different welding conditions. During welding the weld pool was triggered into oscillation by the normal welding pulses or by extra current pulses. The oscillation frequency was measured both during the pulse time and during the base time by analyzing the arc voltage variation using a Fast Fourier Transformation program. Optimal results are obtained when full penetration occurs during the pulse time and partial penetration during the base time. Undermore » these conditions elliptical overlapping spot welds are formed. In the case of full penetration the weld pool oscillates in a low frequency mode (membrane oscillation), whereas in the case of partial penetration the weld pool oscillates in a high frequency mode (surface oscillation). Deviation from the optimal welding conditions occurs when high frequency oscillation is observed during both pulse time and base time (underpenetration) or when low frequency oscillation is observed during both pulse time and base time (overpenetration). In line with these results a penetration sensing system with feedback control was designed, based on the criterion that optimal weld penetration is achieved when two peaks are observed in the frequency distribution. The feasibility of this sensing system for orbital tube welding was confirmed by the results of experiments carried out under various welding conditions.« less

  12. Forming Completely Penetrated Welded T-joints when Pulsed Arc Welding

    NASA Astrophysics Data System (ADS)

    Krampit, N. Yu; Krampit, M. A.; Sapozhkov, A. S.

    2016-04-01

    The paper is focused on revealing the influence of welding parameters on weld formation when pulsed arc welding. As an experimental sample a T-joint over 10 mm was selected. Welding was carried out in flat position, which required no edge preparation but provided mono-directional guaranteed root penetration. The following parameters of welding were subjected to investigation: gap in the joint, wire feed rate and incline angles of the torch along and across the weld axis. Technological recommendations have been made with respect to pulsed arc welding; the cost price of product manufacturing can be reduced on their basis due to reduction of labor input required by machining, lowering consumption of welding materials and electric power.

  13. Control of Gas Tungsten Arc welding pool shape by trace element addition to the weld pool

    DOEpatents

    Heiple, C.R.; Burgardt, P.

    1984-03-13

    An improved process for Gas Tungsten Arc welding maximizes the depth/width ratio of the weld pool by adding a sufficient amount of a surface active element to insure inward fluid flow, resulting in deep, narrow welds. The process is especially useful to eliminate variable weld penetration and shape in GTA welding of steels and stainless steels, particularly by using a sulfur-doped weld wire in a cold wire feed technique.

  14. Electron Beam Welding to Join Gamma Titanium Aluminide Articles

    NASA Technical Reports Server (NTRS)

    Kelly, Thomas Joseph (Inventor)

    2008-01-01

    A method is provided for welding two gamma titanium aluminide articles together. The method includes preheating the two articles to a welding temperature of from about 1700 F to about 2100 F, thereafter electron beam welding the two articles together at the welding temperature and in a welding vacuum to form a welded structure, and thereafter annealing the welded structure at an annealing temperature of from about 1800 F to about 2200 F, to form a joined structure.

  15. Friction Stir Process Mapping Methodology

    NASA Technical Reports Server (NTRS)

    Kooney, Alex; Bjorkman, Gerry; Russell, Carolyn; Smelser, Jerry (Technical Monitor)

    2002-01-01

    In FSW (friction stir welding), the weld process performance for a given weld joint configuration and tool setup is summarized on a 2-D plot of RPM vs. IPM. A process envelope is drawn within the map to identify the range of acceptable welds. The sweet spot is selected as the nominal weld schedule. The nominal weld schedule is characterized in the expected manufacturing environment. The nominal weld schedule in conjunction with process control ensures a consistent and predictable weld performance.

  16. Effect of welding process on the microstructure and properties of dissimilar weld joints between low alloy steel and duplex stainless steel

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Lu, Min-xu; Zhang, Lei; Chang, Wei; Xu, Li-ning; Hu, Li-hua

    2012-06-01

    To obtain high-quality dissimilar weld joints, the processes of metal inert gas (MIG) welding and tungsten inert gas (TIG) welding for duplex stainless steel (DSS) and low alloy steel were compared in this paper. The microstructure and corrosion morphology of dissimilar weld joints were observed by scanning electron microscopy (SEM); the chemical compositions in different zones were detected by energy-dispersive spectroscopy (EDS); the mechanical properties were measured by microhardness test, tensile test, and impact test; the corrosion behavior was evaluated by polarization curves. Obvious concentration gradients of Ni and Cr exist between the fusion boundary and the type II boundary, where the hardness is much higher. The impact toughness of weld metal by MIG welding is higher than that by TIG welding. The corrosion current density of TIG weld metal is higher than that of MIG weld metal in a 3.5wt% NaCl solution. Galvanic corrosion happens between low alloy steel and weld metal, revealing the weakness of low alloy steel in industrial service. The quality of joints produced by MIG welding is better than that by TIG welding in mechanical performance and corrosion resistance. MIG welding with the filler metal ER2009 is the suitable welding process for dissimilar metals jointing between UNS S31803 duplex stainless steel and low alloy steel in practical application.

  17. Study on Dynamic Development of Three-dimensional Weld Pool Surface in Stationary GTAW

    NASA Astrophysics Data System (ADS)

    Huang, Jiankang; He, Jing; He, Xiaoying; Shi, Yu; Fan, Ding

    2018-04-01

    The weld pool contains abundant information about the welding process. In particular, the type of the weld pool surface shape, i. e., convex or concave, is determined by the weld penetration. To detect it, an innovative laser-vision-based sensing method is employed to observe the weld pool surface of the gas tungsten arc welding (GTAW). A low-power laser dots pattern is projected onto the entire weld pool surface. Its reflection is intercepted by a screen and captured by a camera. Then the dynamic development process of the weld pool surface can be detected. By observing and analyzing, the change of the reflected laser dots reflection pattern, for shape of the weld pool surface shape, was found to closely correlate to the penetration of weld pool in the welding process. A mathematical model was proposed to correlate the incident ray, reflected ray, screen and surface of weld pool based on structured laser specular reflection. The dynamic variation of the weld pool surface and its corresponding dots laser pattern were simulated and analyzed. By combining the experimental data and the mathematical analysis, the results show that the pattern of the reflected laser dots pattern is closely correlated to the development of weld pool, such as the weld penetration. The concavity of the pool surface was found to increase rapidly after the surface shape was changed from convex to concave during the stationary GTAW process.

  18. Weld procedure produces quality welds for thick sections of Hastelloy-X

    NASA Technical Reports Server (NTRS)

    Flens, F. J.; Fletcher, C. W.; Glasier, L. F., Jr.

    1967-01-01

    Welding program produces premium quality, multipass welds in heavy tube sections of Hastelloy-X. It develops semiautomatic tungsten/inert gas procedures, weld wire procurement specifications material weld properties, welder-operator training, and nondestructive testing inspection techniques and procedures.

  19. On-line welding quality inspection system for steel pipe based on machine vision

    NASA Astrophysics Data System (ADS)

    Yang, Yang

    2017-05-01

    In recent years, high frequency welding has been widely used in production because of its advantages of simplicity, reliability and high quality. In the production process, how to effectively control the weld penetration welding, ensure full penetration, weld uniform, so as to ensure the welding quality is to solve the problem of the present stage, it is an important research field in the field of welding technology. In this paper, based on the study of some methods of welding inspection, a set of on-line welding quality inspection system based on machine vision is designed.

  20. Fusion welding studies using laser on Ti-SS dissimilar combination

    NASA Astrophysics Data System (ADS)

    Shanmugarajan, B.; Padmanabham, G.

    2012-11-01

    Laser welding investigations were carried out on dissimilar Ti-SS combination. The study is aimed to improve the weld strength and ductility by minimizing harmful intermetallics and taking advantage of high cooling rates in laser welding. Results of continuous wave 3.5 kW CO2 laser welding of totally dissimilar combination of Titanium and stainless steel (304) have been discussed. Bead on plate welding experiments were conducted to identify the laser welding parameters using depth of penetration as criteria. The welding of dissimilar combination has been attempted both autogenously and with interlayers such as Vanadium (V) and Tantalum (Ta) in the form of laser cladding as well as strip. Autogenous welds were carried out by varying the laser power, welding speed and position of the laser beam with respect to the joint centre. The resultant welds are characterized by macrostructure analysis, SEM/EDAX and XRD and as welded tensile test in UTM. The autogenous welds have exhibited extensive cracking even when welded at high speeds or by manipulating the beam position with respect to the joint. Similarly Vandaium as interlayer could not achieve crack free joint. A joint with 40 MPa strength could be made with Ta as interlayer. Results and analysis of these variants of laser welded joints are reported and discussed.

  1. Thermo-Mechanical Analysis of a Single-Pass Weld Overlay and Girth Welding in Lined Pipe

    NASA Astrophysics Data System (ADS)

    Obeid, Obeid; Alfano, Giulio; Bahai, Hamid

    2017-08-01

    The paper presents a nonlinear heat-transfer and mechanical finite-element (FE) analyses of a two-pass welding process of two segments of lined pipe made of a SUS304 stainless steel liner and a C-Mn steel pipe. The two passes consist of the single-pass overlay welding (inner lap weld) of the liner with the C-Mn steel pipe for each segment and the single-pass girth welding (outer butt weld) of the two segments. A distributed power density of the moving welding torch and a nonlinear heat-transfer coefficient accounting for both radiation and convection have been used in the analysis and implemented in user subroutines for the FE code ABAQUS. The modeling procedure has been validated against previously published experimental results for stainless steel and carbon steel welding separately. The model has been then used to determine the isotherms induced by the weld overlay and the girth welding and to clarify their influence on the transient temperature field and residual stress in the lined pipe. Furthermore, the influence of the cooling time between weld overlay and girth welding and of the welding speed have been examined thermally and mechanically as they are key factors that can affect the quality of lined pipe welding.

  2. Welded joints integrity analysis and optimization for fiber laser welding of dissimilar materials

    NASA Astrophysics Data System (ADS)

    Ai, Yuewei; Shao, Xinyu; Jiang, Ping; Li, Peigen; Liu, Yang; Liu, Wei

    2016-11-01

    Dissimilar materials welded joints provide many advantages in power, automotive, chemical, and spacecraft industries. The weld bead integrity which is determined by process parameters plays a significant role in the welding quality during the fiber laser welding (FLW) of dissimilar materials. In this paper, an optimization method by taking the integrity of the weld bead and weld area into consideration is proposed for FLW of dissimilar materials, the low carbon steel and stainless steel. The relationships between the weld bead integrity and process parameters are developed by the genetic algorithm optimized back propagation neural network (GA-BPNN). The particle swarm optimization (PSO) algorithm is taken for optimizing the predicted outputs from GA-BPNN for the objective. Through the optimization process, the desired weld bead with good integrity and minimum weld area are obtained and the corresponding microstructure and microhardness are excellent. The mechanical properties of the optimized joints are greatly improved compared with that of the un-optimized welded joints. Moreover, the effects of significant factors are analyzed based on the statistical approach and the laser power (LP) is identified as the most significant factor on the weld bead integrity and weld area. The results indicate that the proposed method is effective for improving the reliability and stability of welded joints in the practical production.

  3. Influence of M-TIG and A-TIG Welding Process on Microstructure and Mechanical Behavior of 409 Ferritic Stainless Steel

    NASA Astrophysics Data System (ADS)

    Vidyarthy, R. S.; Dwivedi, D. K.; Vasudevan, M.

    2017-03-01

    The current study investigates the effects of activating flux tungsten inert gas welding (A-TIG) and multipass tungsten inert gas welding (M-TIG) on the weld morphology, angular distortion, microstructures and mechanical properties when welding 8-mm-thick 409 ferritic stainless steel (FSS). SiO2 was used as activating flux for A-TIG welding, while SUPERTIG ER309L was used as filler for M-TIG welding. Bead-on-plate weld trials were carried out to obtain the full penetration by using different combinations of flux coating density, welding speed and welding current. An optical microscope, field emission scanning microscope (FESEM), and x-ray diffractometer were used for the metallurgical characterizations. Vickers hardness, tensile test, Charpy toughness test, and creep behavior test were carried out to evaluate the mechanical properties of the base and weld metals. Experimental results indicate that the A-TIG process can increase the joint penetration and tends to reduce the angular distortion of the 409 FSS weldment. The A-TIG welded joint also exhibited greater mechanical strength. However, a critically low Charpy toughness was measured for the A-TIG weld fusion zone, which was later sufficiently improved after post weld heat treatment (PWHT). It was concluded that PWHT is mandatory for A-TIG welded 409 FSS.

  4. Laser angioplasty for cardiovascular disease

    NASA Astrophysics Data System (ADS)

    Okada, Masayoshi

    2005-07-01

    Recently, endovascular interventions such as balloon angioplasty, atherectomy and the stenting method, except for conventional surgery have been clinically employed for the patients with atheromatous plaques of the peripheral- and the coronary arteries, because the number of patients with arteriosclerosis is now increasing in the worldwide. Among these procedures, restenoses after endovascular interventions have been remarkably disclosed in 20-40 % of the patients who underwent percutaneous coronary interventions. Thus, there are still some problems in keeping long-term patency by means of endovascular techniques such as balloon angioplasty and atherectomy (1, 2). For reduction of these problems , laser angioplasty using Argon laser was applied experimentally and clinically. Based on excellent experimental studies, laser was employed for 115 patients with stenotic ,or obstructive lesions occluding more thasn 75 % of the peripheral and the coronary arteries angiographycally.

  5. The impact of changing intracranial aneurysm practice on the education of cerebrovascular neurosurgeons.

    PubMed

    Lai, Leon; Morgan, Michael Kerin

    2012-01-01

    Endovascular repair of intracranial aneurysms has transformed the practice of cerebrovascular surgery. We reviewed the National Hospital Morbidity Database in Australia for the years 2000 to 2008 and investigated the changing trends of aneurysm practice. During this period 7,503 craniotomies for aneurysm repair and 7,863 endovascular coiling procedures were performed. The number of aneurysm procedures performed surgically reduced from 9 cases per neurosurgeon per year to 4.2 cases, a reduction of 53.3%. The number of endovascular treatments increased 2.1 fold, from 3.6 aneurysms per neurosurgeon in 2000 to 7.5 in 2008. The implications of reduced numbers of surgically treated aneurysms were considered for the education of cerebrovascular neurosurgeons in Australia. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Logistic considerations for a successful institutional approach to the endovascular repair of ruptured abdominal aortic aneurysms.

    PubMed

    Mayer, Dieter; Rancic, Zoran; Pfammatter, Thomas; Hechelhammer, Lukas; Veith, Frank J; Donas, Konstantin; Lachat, Mario

    2010-01-01

    The value of emergency endovascular aneurysm repair (EVAR) in the setting of ruptured abdominal aortic aneurysm remains controversial owing to differing results. However, interpretation of published results remains difficult as there is a lack of generally accepted protocols or standard operating procedures. Furthermore, such protocols and standard operating procedures often are reported incompletely or not at all, thereby making interpretation of results difficult. We herein report our integrated logistic system for the endovascular treatment of ruptured abdominal aortic aneurysms. Important components of this system are prehospital logistics, in-hospital treatment logistics, and aftercare. Further studies should include details about all of these components, and a description of these logistic components must be included in all future studies of emergency EVAR for ruptured abdominal aortic aneurysms.

  7. Innovative Chimney-Graft Technique for Endovascular Repair of a Pararenal Abdominal Aortic Aneurysm

    PubMed Central

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A.

    2015-01-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta. PMID:25873796

  8. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    PubMed

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  9. Hydrogels in endovascular embolization. III. Radiopaque spherical particles, their preparation and properties.

    PubMed

    Horák, D; Metalová, M; Svec, F; Drobník, J; Kálal, J; Borovicka, M; Adamyan, A A; Voronkova, O S; Gumargalieva, K Z

    1987-03-01

    The synthesis and properties of spherical radiopaque hydrogel particles designed for endovascular occlusion are reported. These particles were prepared by the hydroxyl acylation of low crosslinked poly (2-hydroxyethyl methacrylate) beads with a nontoxic radiopaque compound based on triiodobenzoic acid, without affecting their properties which are advantages in medical practice. The effect of the iodine content on the size of dry and swollen particles is discussed. It has been found that an iodine content of about 25-30 wt% is desirable in order to obtain an easily recognizable X-ray image. These particles make the immediate control of embolus application easy and enable periodical inspection of the polymer to check the successful blockage of the vessel. They also open up the method of endovascular occlusion to further improvement.

  10. Explanting the Nellix Endovascular Aortic Sealing Endoprosthesis for Proximal Aortic Neck Failure.

    PubMed

    Lee, Cheong Jun; Cuff, Robert

    2018-05-17

    Open conversion following endovascular aortic repair (EVAR) has inherent challenges particular to the device being explanted. The Nellix endograft is unlike any other device as it utilizes polymer filling of endobags within the aorto-iliac lumen to seal the AAA sac; a developing concept known as endovascular aortic sealing (EVAS). Conversion to open repair of AAA treated with the Nellix endograft have rarely been discussed. Explants that have been previously reported were for graft infection. We present two Nellix graft explants that were required for device migration and subsequent development of a type IA endoleak. The technique and nuances observed during open conversion of this novel endograft for proximal aortic neck failure is described in this report. Copyright © 2018. Published by Elsevier Inc.

  11. Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases.

    PubMed

    Son, Donghee; Lee, Jongha; Lee, Dong Jun; Ghaffari, Roozbeh; Yun, Sumin; Kim, Seok Joo; Lee, Ji Eun; Cho, Hye Rim; Yoon, Soonho; Yang, Shixuan; Lee, Seunghyun; Qiao, Shutao; Ling, Daishun; Shin, Sanghun; Song, Jun-Kyul; Kim, Jaemin; Kim, Taeho; Lee, Hakyong; Kim, Jonghoon; Soh, Min; Lee, Nohyun; Hwang, Cheol Seong; Nam, Sangwook; Lu, Nanshu; Hyeon, Taeghwan; Choi, Seung Hong; Kim, Dae-Hyeong

    2015-06-23

    Implantable endovascular devices such as bare metal, drug eluting, and bioresorbable stents have transformed interventional care by providing continuous structural and mechanical support to many peripheral, neural, and coronary arteries affected by blockage. Although effective in achieving immediate restoration of blood flow, the long-term re-endothelialization and inflammation induced by mechanical stents are difficult to diagnose or treat. Here we present nanomaterial designs and integration strategies for the bioresorbable electronic stent with drug-infused functionalized nanoparticles to enable flow sensing, temperature monitoring, data storage, wireless power/data transmission, inflammation suppression, localized drug delivery, and hyperthermia therapy. In vivo and ex vivo animal experiments as well as in vitro cell studies demonstrate the previously unrecognized potential for bioresorbable electronic implants coupled with bioinert therapeutic nanoparticles in the endovascular system.

  12. 30 CFR 250.110 - What must I include in my welding plan?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What must I include in my welding plan? 250.110... must I include in my welding plan? You must include all of the following in the Welding Plan that you... qualified personnel weld; (c) Practices and procedures for safe welding that address: (1) Welding in...

  13. U-Groove Aluminum Weld Strength Improvement

    NASA Technical Reports Server (NTRS)

    Verderaime, V.; Vaughan, R.

    1997-01-01

    Though butt-welds are among the most preferred joining methods in aerostructures, their strength dependence on inelastic mechanics is generally the least understood. This study investigated experimental strain distributions across a thick aluminum U-grooved weld and identified two weld process considerations for improving the multipass weld strength. One is the source of peaking in which the extreme thermal expansion and contraction gradient of the fusion heat input across the groove tab thickness produces severe angular distortion that induces bending under uniaxial loading. The other is the filler strain hardening decreasing with increasing filler pass sequences, producing the weakest welds on the last weld pass side. Both phenomena are governed by weld pass sequences. Many industrial welding schedules unknowingly compound these effects, which reduce the weld strength. A depeaking index model was developed to select filler pass thickness, pass numbers, and sequences to improve depeaking in the welding process. The result was to select the number and sequence of weld passes to reverse the peaking angle such as to combine the strongest weld pass side with the peaking induced bending tension component side to provide a more uniform stress and stronger weld under axial tensile loading.

  14. Fluid Flow Phenomena during Welding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Wei

    2011-01-01

    MOLTEN WELD POOLS are dynamic. Liquid in the weld pool in acted on by several strong forces, which can result in high-velocity fluid motion. Fluid flow velocities exceeding 1 m/s (3.3 ft/s) have been observed in gas tungsten arc (GTA) welds under ordinary welding conditions, and higher velocities have been measured in submerged arc welds. Fluid flow is important because it affects weld shape and is related to the formation of a variety of weld defects. Moving liquid transports heat and often dominates heat transport in the weld pool. Because heat transport by mass flow depends on the direction andmore » speed of fluid motion, weld pool shape can differ dramatically from that predicted by conductive heat flow. Temperature gradients are also altered by fluid flow, which can affect weld microstructure. A number of defects in GTA welds have been attributed to fluid flow or changes in fluid flow, including lack of penetration, top bead roughness, humped beads, finger penetration, and undercutting. Instabilities in the liquid film around the keyhole in electron beam and laser welds are responsible for the uneven penetration (spiking) characteristic of these types of welds.« less

  15. Enabling high speed friction stir welding of aluminum tailor welded blanks

    NASA Astrophysics Data System (ADS)

    Hovanski, Yuri

    Current welding technologies for production of aluminum tailor-welded blanks (TWBs) are utilized in low-volume and niche applications, and have yet to be scaled for the high-volume vehicle market. This study targeted further weight reduction, part reduction, and cost savings by enabling tailor-welded blank technology for aluminum alloys at high-volumes. While friction stir welding (FSW) has traditionally been applied at linear velocities less than one meter per minute, high volume production applications demand the process be extended to higher velocities more amenable to cost sensitive production environments. Unfortunately, weld parameters and performance developed and characterized at low to moderate welding velocities do not directly translate to high speed linear friction stir welding. Therefore, in order to facilitate production of high volume aluminum FSW components, parameters were developed with a minimum welding velocity of three meters per minute. With an emphasis on weld quality, welded blanks were evaluated for post-weld formability using a combination of numerical and experimental methods. Evaluation across scales was ultimately validated by stamping full-size production door inner panels made from dissimilar thickness aluminum tailor-welded blanks, which provided validation of the numerical and experimental analysis of laboratory scale tests.

  16. Automatic welding of stainless steel tubing

    NASA Technical Reports Server (NTRS)

    Clautice, W. E.

    1978-01-01

    The use of automatic welding for making girth welds in stainless steel tubing was investigated as well as the reduction in fabrication costs resulting from the elimination of radiographic inspection. Test methodology, materials, and techniques are discussed, and data sheets for individual tests are included. Process variables studied include welding amperes, revolutions per minute, and shielding gas flow. Strip chart recordings, as a definitive method of insuring weld quality, are studied. Test results, determined by both radiographic and visual inspection, are presented and indicate that once optimum welding procedures for specific sizes of tubing are established, and the welding machine operations are certified, then the automatic tube welding process produces good quality welds repeatedly, with a high degree of reliability. Revised specifications for welding tubing using the automatic process and weld visual inspection requirements at the Kennedy Space Center are enumerated.

  17. Integrated optical sensor

    DOEpatents

    Watkins, Arthur D.; Smartt, Herschel B.; Taylor, Paul L.

    1994-01-01

    An integrated optical sensor for arc welding having multifunction feedback control. The sensor, comprising generally a CCD camera and diode laser, is positioned behind the arc torch for measuring weld pool position and width, standoff distance, and post-weld centerline cooling rate. Computer process information from this sensor is passed to a controlling computer for use in feedback control loops to aid in the control of the welding process. Weld pool position and width are used in a feedback loop, by the weld controller, to track the weld pool relative to the weld joint. Sensor standoff distance is used in a feedback loop to control the contact tip to base metal distance during the welding process. Cooling rate information is used to determine the final metallurgical state of the weld bead and heat affected zone, thereby controlling post-weld mechanical properties.

  18. Integrated optical sensor

    DOEpatents

    Watkins, A.D.; Smartt, H.B.; Taylor, P.L.

    1994-01-04

    An integrated optical sensor for arc welding having multifunction feedback control is described. The sensor, comprising generally a CCD camera and diode laser, is positioned behind the arc torch for measuring weld pool position and width, standoff distance, and post-weld centerline cooling rate. Computer process information from this sensor is passed to a controlling computer for use in feedback control loops to aid in the control of the welding process. Weld pool position and width are used in a feedback loop, by the weld controller, to track the weld pool relative to the weld joint. Sensor standoff distance is used in a feedback loop to control the contact tip to base metal distance during the welding process. Cooling rate information is used to determine the final metallurgical state of the weld bead and heat affected zone, thereby controlling post-weld mechanical properties. 6 figures.

  19. The Effect of Welding Energy on the Microstructural and Mechanical Properties of Ultrasonic-Welded Copper Joints

    PubMed Central

    Yang, Jingwei; Cao, Biao; Lu, Qinghua

    2017-01-01

    The effects of welding energy on the mechanical and microstructural characteristics of ultrasonic-welded pure copper plates were investigated. Complex dynamic recrystallization and grain growth occurred inside the weld zone during ultrasonic welding. At a low welding energy, a thin band of straight weld interfaces was observed and had an ultra-fine grain structure. With an increase in welding energy, the weld interface progressively changed from flat to sinusoidal, and eventually turned into a convoluted wavy pattern, bearing similarities to shear instabilities, as observed in fluid dynamics. The lap shear load of the joints initially increased and then remained stable as the welding energy increased. The tensile characteristics of the joints significantly depended on the development of plastic deformation at the interface. The influence of the microstructure on the hardness was also discussed. PMID:28772553

  20. Evaluation of Residual Stress Measurements Before and After Post-Weld Heat Treatment in the Weld Repairs

    NASA Astrophysics Data System (ADS)

    Pardowska, Anna M.; Price, John W. H.; Finlayson, Trevor R.; Ibrahim, R.

    2010-11-01

    Welding repairs are increasingly a structural integrity concern for aging pressure vessel and piping components. It has been demonstrated that the residual stress distribution near repair welds can be drastically different from that of the original weld. Residual stresses have a significant effect on the lifetime performance of a weld, and a reduction of these stresses is normally desirable. The aim of this paper is to investigate residual stresses in various weld repair arrangements using the non-destructive neutron diffraction technique. This research is focused on characterization of the residual stress distribution: (i) in the original weld; (ii) in a shallow toe weld repair; and (iii) after conventional post-weld heat treatment. The focus of the measurements is on the values of the subsurface strain/stress variations across the weld.

  1. The Effect of Welding Energy on the Microstructural and Mechanical Properties of Ultrasonic-Welded Copper Joints.

    PubMed

    Yang, Jingwei; Cao, Biao; Lu, Qinghua

    2017-02-16

    The effects of welding energy on the mechanical and microstructural characteristics of ultrasonic-welded pure copper plates were investigated. Complex dynamic recrystallization and grain growth occurred inside the weld zone during ultrasonic welding. At a low welding energy, a thin band of straight weld interfaces was observed and had an ultra-fine grain structure. With an increase in welding energy, the weld interface progressively changed from flat to sinusoidal, and eventually turned into a convoluted wavy pattern, bearing similarities to shear instabilities, as observed in fluid dynamics. The lap shear load of the joints initially increased and then remained stable as the welding energy increased. The tensile characteristics of the joints significantly depended on the development of plastic deformation at the interface. The influence of the microstructure on the hardness was also discussed.

  2. Advanced fusion welding processes, solid state joining and a successful marriage. [production of aerospace structures

    NASA Technical Reports Server (NTRS)

    Miller, F. R.

    1972-01-01

    Joining processes for aerospace systems combine fusion welding and solid state joining during production of metal structures. Detailed characteristics of electron beam welding, plasma arc welding, diffusion welding, inertia welding and weldbond processes are discussed.

  3. Grinding Parts For Automatic Welding

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.; Hoult, William S.

    1989-01-01

    Rollers guide grinding tool along prospective welding path. Skatelike fixture holds rotary grinder or file for machining large-diameter rings or ring segments in preparation for welding. Operator grasps handles to push rolling fixture along part. Rollers maintain precise dimensional relationship so grinding wheel cuts precise depth. Fixture-mounted grinder machines surface to quality sufficient for automatic welding; manual welding with attendant variations and distortion not necessary. Developed to enable automatic welding of parts, manual welding of which resulted in weld bead permeated with microscopic fissures.

  4. Method for controlling gas metal arc welding

    DOEpatents

    Smartt, Herschel B.; Einerson, Carolyn J.; Watkins, Arthur D.

    1989-01-01

    The heat input and mass input in a Gas Metal Arc welding process are controlled by a method that comprises calculating appropriate values for weld speed, filler wire feed rate and an expected value for the welding current by algorithmic function means, applying such values for weld speed and filler wire feed rate to the welding process, measuring the welding current, comparing the measured current to the calculated current, using said comparison to calculate corrections for the weld speed and filler wire feed rate, and applying corrections.

  5. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid And Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial

    PubMed Central

    Ederle, Jörg; Bonati, Leo H; Dobson, Joanna; Featherstone, Roland L; Gaines, Peter A; Beard, Jonathan D; Venables, Graham S; Markus, Hugh S; Clifton, Andrew; Sandercock, Peter; Brown, Martin M

    2009-01-01

    Summary Background Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS). Methods Between March, 1992, and July, 1997, patients who presented at a participating centre with a confirmed stenosis of the internal carotid artery that was deemed equally suitable for either carotid endarterectomy or endovascular treatment were randomly assigned to either treatment in equal proportions by telephone or fax from the randomisation service at the Oxford Clinical Trials Unit, UK. Patients were seen by an independent neurologist at 1 and 6 months after treatment and then every year after randomisation for as long as possible, up to a maximum of 11 years. Major outcome events were transient ischaemic attack, non-disabling, disabling, and fatal stroke, myocardial infarction, and death from any other cause. Outcomes were adjudicated on by investigators who were masked to treatment. Analysis was by intention to treat. This study is registered, number ISRCTN 01425573. Findings 504 patients with stenosis of the carotid artery (90% symptomatic) were randomly assigned to endovascular treatment (n=251) or surgery (n=253). Within 30 days of treatment, there were more minor strokes that lasted less than 7 days in the endovascular group (8 vs 1) but the number of other strokes in any territory or death was the same (25 vs 25). There were more cranial nerve palsies (22 vs 0) in the endarterectomy group than in the endovascular group. Median length of follow up in both groups was 5 years (IQR 2–6). By comparing endovascular treatment with endarterectomy after the 30-day post-treatment period, the 8-year incidence and hazard ratio (HR) at the end of follow-up for ipsilateral non-perioperative stroke was 11·3% versus 8·6% (HR 1·22, 95% CI 0·59–2·54); for ipsilateral non-perioperative stroke or TIA was 19·3% versus 17·2% (1·29, 0·78–2·14); and for any non-perioperative stroke was 21·1% versus 15·4% (1·66, 0·99–2·80). Interpretation More patients had stroke during follow-up in the endovascular group than in the surgical group, but the rate of ipsilateral non-perioperative stroke was low in both groups and none of the differences in the stroke outcome measures was significant. However, the study was underpowered and the confidence intervals were wide. More long-term data are needed from the on going stenting versus endarterectomy trials. Funding British Heart Foundation; UK National Health Service Management Executive; UK Stroke Association. PMID:19717345

  6. Effects of Pulse Parameters on Weld Microstructure and Mechanical Properties of Extra Pulse Current Aided Laser Welded 2219 Aluminum Alloy Joints.

    PubMed

    Zhang, Xinge; Li, Liqun; Chen, Yanbin; Yang, Zhaojun; Chen, Yanli; Guo, Xinjian

    2017-09-15

    In order to expand the application range of laser welding and improve weld quality, an extra pulse current was used to aid laser-welded 2219 aluminum alloy, and the effects of pulse current parameters on the weld microstructure and mechanical properties were investigated. The effect mechanisms of the pulse current interactions with the weld pool were evaluated. The results indicated that the coarse dendritic structure in the weld zone changed to a fine equiaxed structure using an extra pulse current, and the pulse parameters, including medium peak current, relatively high pulse frequency, and low pulse duty ratio benefited to improving the weld structure. The effect mechanisms of the pulse current were mainly ascribed to the magnetic pinch effect, thermal effect, and electromigration effect caused by the pulse current. The effect of the pulse parameters on the mechanical properties of welded joints were consistent with that of the weld microstructure. The tensile strength and elongation of the optimal pulse current-aided laser-welded joint increased by 16.4% and 105%, respectively, compared with autogenous laser welding.

  7. Effects of Pulse Parameters on Weld Microstructure and Mechanical Properties of Extra Pulse Current Aided Laser Welded 2219 Aluminum Alloy Joints

    PubMed Central

    Zhang, Xinge; Li, Liqun; Chen, Yanbin; Yang, Zhaojun; Chen, Yanli; Guo, Xinjian

    2017-01-01

    In order to expand the application range of laser welding and improve weld quality, an extra pulse current was used to aid laser-welded 2219 aluminum alloy, and the effects of pulse current parameters on the weld microstructure and mechanical properties were investigated. The effect mechanisms of the pulse current interactions with the weld pool were evaluated. The results indicated that the coarse dendritic structure in the weld zone changed to a fine equiaxed structure using an extra pulse current, and the pulse parameters, including medium peak current, relatively high pulse frequency, and low pulse duty ratio benefited to improving the weld structure. The effect mechanisms of the pulse current were mainly ascribed to the magnetic pinch effect, thermal effect, and electromigration effect caused by the pulse current. The effect of the pulse parameters on the mechanical properties of welded joints were consistent with that of the weld microstructure. The tensile strength and elongation of the optimal pulse current-aided laser-welded joint increased by 16.4% and 105%, respectively, compared with autogenous laser welding. PMID:28914825

  8. Active weld control

    NASA Technical Reports Server (NTRS)

    Powell, Bradley W.; Burroughs, Ivan A.

    1994-01-01

    Through the two phases of this contract, sensors for welding applications and parameter extraction algorithms have been developed. These sensors form the foundation of a weld control system which can provide action weld control through the monitoring of the weld pool and keyhole in a VPPA welding process. Systems of this type offer the potential of quality enhancement and cost reduction (minimization of rework on faulty welds) for high-integrity welding applications. Sensors for preweld and postweld inspection, weld pool monitoring, keyhole/weld wire entry monitoring, and seam tracking were developed. Algorithms for signal extraction were also developed and analyzed to determine their application to an adaptive weld control system. The following sections discuss findings for each of the three sensors developed under this contract: (1) weld profiling sensor; (2) weld pool sensor; and (3) stereo seam tracker/keyhole imaging sensor. Hardened versions of these sensors were designed and built under this contract. A control system, described later, was developed on a multiprocessing/multitasking operating system for maximum power and flexibility. Documentation for sensor mechanical and electrical design is also included as appendices in this report.

  9. Optimization of laser welding thin-gage galvanized steel via response surface methodology

    NASA Astrophysics Data System (ADS)

    Zhao, Yangyang; Zhang, Yansong; Hu, Wei; Lai, Xinmin

    2012-09-01

    The increasing demand of light weight and durability makes thin-gage galvanized steels (<0.6 mm) attractive for future automotive applications. Laser welding, well known for its deep penetration, high speed and small heat affected zone, provides a potential solution for welding thin-gage galvanized steels in automotive industry. In this study, the effect of the laser welding parameters (i.e. laser power, welding speed, gap and focal position) on the weld bead geometry (i.e. weld depth, weld width and surface concave) of 0.4 mm-thick galvanized SAE1004 steel in a lap joint configuration has been investigated by experiments. The process windows of the concerned process parameters were therefore determined. Then, response surface methodology (RSM) was used to develop models to predict the relationship between the processing parameters and the laser weld bead profile and identify the correct and optimal combination of the laser welding input variables to obtain superior weld joint. Under the optimal welding parameters, defect-free weld were produced, and the average aspect ratio increased about 30%, from 0.62 to 0.83.

  10. Effect of Multipass TIG and Activated TIG Welding Process on the Thermo-Mechanical Behavior of 316LN Stainless Steel Weld Joints

    NASA Astrophysics Data System (ADS)

    Ganesh, K. C.; Balasubramanian, K. R.; Vasudevan, M.; Vasantharaja, P.; Chandrasekhar, N.

    2016-04-01

    The primary objective of this work was to develop a finite element model to predict the thermo-mechanical behavior of an activated tungsten inert gas (ATIG)-welded joint. The ATIG-welded joint was fabricated using 10 mm thickness of 316LN stainless steel plates in a single pass. To distinguish the merits of ATIG welding process, it was compared with manual multipass tungsten inert gas (MPTIG)-welded joint. The ATIG-welded joint was fabricated with square butt edge configuration using an activating flux developed in-house. The MPTIG-welded joint was fabricated in thirteen passes with V-groove edge configuration. The finite element model was developed to predict the transient temperature, residual stress, and distortion of the welded joints. Also, microhardness, impact toughness, tensile strength, ferrite measurement, and microstructure were characterized. Since most of the recent publications of ATIG-welded joint was focused on the molten weld pool dynamics, this research work gives an insight on the thermo-mechanical behavior of ATIG-welded joint over MPTIG-welded joint.

  11. Interaction of both plasmas in CO2 laser-MAG hybrid welding of carbon steel

    NASA Astrophysics Data System (ADS)

    Kutsuna, Muneharu; Chen, Liang

    2003-03-01

    Researches and developments of laser and arc hybrid welding has been curried out since in 1978. Especially, CO2 laser and TIG hybrid welding has been studied for increasing the penetration depth and welding speed. Recently laser and MIG/MAG/Plasma hybrid welding processes have been developed and applied to industries. It was recognized as a new welding process that promote the flexibility of the process for increasing the penetration depth, welding speed and allowable joint gap and improving the quality of the welds. In the present work, CO2 Laser-MAG hybrid welding of carbon steel (SM490) was investigated to make clear the phenomenon and characteristics of hybrid welding process comparing with laser welding and MAG process. The effects of many process parameters such as welding current, arc voltage, welding speed, defocusing distance, laser-to-arc distance on penetration depth, bead shape, spatter, arc stability and plasma formation were investigated in the present work. Especially, the interaction of laser plasma and MAG arc plasma was considered by changing the laser to arc distance (=DLA).

  12. Upgraded HFIR Fuel Element Welding System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sease, John D

    2010-02-01

    The welding of aluminum-clad fuel plates into aluminum alloy 6061 side plate tubing is a unique design feature of the High Flux Isotope Reactor (HFIR) fuel assemblies as 101 full-penetration circumferential gas metal arc welds (GMAW) are required in the fabrication of each assembly. In a HFIR fuel assembly, 540 aluminum-clad fuel plates are assembled into two nested annular fuel elements 610 mm (24-inches) long. The welding process for the HFIR fuel elements was developed in the early 1960 s and about 450 HFIR fuel assemblies have been successfully welded using the GMAW process qualified in the 1960 s. Inmore » recent years because of the degradation of the electronic and mechanical components in the old HFIR welding system, reportable defects in plate attachment or adapter welds have been present in almost all completed fuel assemblies. In October 2008, a contract was awarded to AMET, Inc., of Rexburg, Idaho, to replace the old welding equipment with standard commercially available welding components to the maximum extent possible while maintaining the qualified HFIR welding process. The upgraded HFIR welding system represents a major improvement in the welding system used in welding HFIR fuel elements for the previous 40 years. In this upgrade, the new inner GMAW torch is a significant advancement over the original inner GMAW torch previously used. The innovative breakthrough in the new inner welding torch design is the way the direction of the cast in the 0.762 mm (0.030-inch) diameter aluminum weld wire is changed so that the weld wire emerging from the contact tip is straight in the plane perpendicular to the welding direction without creating any significant drag resistance in the feeding of the weld wire.« less

  13. Development of an intelligent system for cooling rate and fill control in GMAW

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Einerson, C.J.; Smartt, H.B.; Johnson, J.A.

    1992-09-01

    A control strategy for gas metal arc welding (GMAW) is developed in which the welding system detects certain existing conditions and adjusts the process in accordance to pre-specified rules. This strategy is used to control the reinforcement and weld bead centerline cooling rate during welding. Relationships between heat and mass transfer rates to the base metal and the required electrode speed and welding speed for specific open circuit voltages are taught to a artificial neural network. Control rules are programmed into a fuzzy logic system. TRADITOINAL CONTROL OF THE GMAW PROCESS is based on the use of explicit welding proceduresmore » detailing allowable parameter ranges on a pass by pass basis for a given weld. The present work is an exploration of a completely different approach to welding control. In this work the objectives are to produce welds having desired weld bead reinforcements while maintaining the weld bead centerline cooling rate at preselected values. The need for this specific control is related to fabrication requirements for specific types of pressure vessels. The control strategy involves measuring weld joint transverse cross-sectional area ahead of the welding torch and the weld bead centerline cooling rate behind the weld pool, both by means of video (2), calculating the required process parameters necessary to obtain the needed heat and mass transfer rates (in appropriate dimensions) by means of an artificial neural network, and controlling the heat transfer rate by means of a fuzzy logic controller (3). The result is a welding machine that senses the welding conditions and responds to those conditions on the basis of logical rules, as opposed to producing a weld based on a specific procedure.« less

  14. Development of automatic pre-tracking system for fillet weld based on laser trigonometry

    NASA Astrophysics Data System (ADS)

    Shen, Xiaoqin; Yu, Fusheng

    2005-01-01

    In this paper, an automatic fillet weld pre-tracking system for welding the work piece of lorry back boards with several bend in haul automobile is developed basing on laser trigonometry. The optical measuring head based on laser-PSD trigonometry is used as position sensor. It is placed in front of the traveling direction of welding wire to get the distances from welding wire to the two side boards of the welding lines, upper board and bottom board of the fillet weld respectively. A chip of AT89S52 is used as the micro controller in this system. The AC servomotors, ball-screws and straight guide rails constitute the sliding table to take welding wire move. The laser-PSD sensors pass through the vertical board, upper board and bottom board of the fillet weld when welding wire moves and then get the distance. The laser-PSD sensors output the analog signals. After A/D conversion, the digital signal is input into AT89S52 and calculated. Then the information of the position and lateral deviation of the welding wire when welding a certain position are gotten to control welding wires. So the weld pre-tracking for welding the work piece with long distance and large bend in haul automobile is realized. The position information is input into EEPROM to be saved for short time after handled by AT89S52. The information is as the welding position information as well as the speed adjusting data of the welding wire when it welds the several bend of the work piece. The practice indicates that this system has high pre-tracking precision, good anti-disturb ability, excellent reliability, easy operating ability and good adaptability to the field of production.

  15. Friction Stir Welding of Tapered Thickness Welds Using an Adjustable Pin Tool

    NASA Technical Reports Server (NTRS)

    Adams, Glynn; Venable, Richard; Lawless, Kirby

    2003-01-01

    Friction stir welding (FSW) can be used for joining weld lands that vary in thickness along the length of the weld. An adjustable pin tool mechanism can be used to accomplish this in a single-pass, full-penetration weld by providing for precise changes in the pin length relative to the shoulder face during the weld process. The difficulty with this approach is in accurately adjusting the pin length to provide a consistent penetration ligament throughout the weld. The weld technique, control system, and instrumentation must account for mechanical and thermal compliances of the tooling system to conduct tapered welds successfully. In this study, a combination of static and in-situ measurements, as well as active control, is used to locate the pin accurately and maintain the desired penetration ligament. Frictional forces at the pin/shoulder interface were a source of error that affected accurate pin position. A traditional FSW pin tool design that requires a lead angle was used to join butt weld configurations that included both constant thickness and tapered sections. The pitch axis of the tooling was fixed throughout the weld; therefore, the effective lead angle in the tapered sections was restricted to within the tolerances allowed by the pin tool design. The sensitivity of the FSW process to factors such as thickness offset, joint gap, centerline offset, and taper transition offset were also studied. The joint gap and the thickness offset demonstrated the most adverse affects on the weld quality. Two separate tooling configurations were used to conduct tapered thickness welds successfully. The weld configurations included sections in which the thickness decreased along the weld, as well as sections in which the thickness increased along the weld. The data presented here include weld metallography, strength data, and process load data.

  16. Properties of the welded joints of manganese steel made by low-frequency pulsed arc welding

    NASA Astrophysics Data System (ADS)

    Saraev, Yu. N.; Bezborodov, V. P.; Gladovskii, S. V.; Golikov, N. I.

    2017-04-01

    The structure, the mechanical properties, the impact toughness, and the fracture mechanisms of the welded joints made of steel 09G2S plates by direct current welding and pulsed arc welding with a modulated arc current in the frequency range 0.25-5.0 Hz are studied. The application of low-frequency pulsed arc welding allowed us to form welded joints with a fine-grained structure in the weld metal and the heat-affected zone and to achieve a higher impact toughness and a longer cyclic fatigue life as compared to the welded joints fabricated by direct current welding. The achieved effect manifests itself over the entire testing range from 20 to-60°C.

  17. High Power Laser Welding. [of stainless steel and titanium alloy structures

    NASA Technical Reports Server (NTRS)

    Banas, C. M.

    1972-01-01

    A review of recent developments in high power, carbon dixoide laser welding is presented. Deep penetration welding in stainless steel to 0.5-in. thick, high speed welding in thin gage rimmed steel and gas shielded welding in Ti-6Al-4V alloy are described. The effects of laser power, power density, focusing optics, gas-shielding techniques, material properties and weld speed on weld quality and penetration are discussed. It is shown that laser welding performance in thin materials is comparable to that of electron beams. It is further shown that high quality welds, as evidenced by NDT, mechanical and metal-lographic tests, can be achieved. The potential of the laser for industrial welding applications is indicated.

  18. On the hot cracking susceptibility of a semisolid aluminium 6061 weld: Application of a coupled solidification- thermomechanical model

    NASA Astrophysics Data System (ADS)

    Zareie Rajani, H. R.; Phillion, A. B.

    2015-06-01

    A coupled solidification-thermomechanical model is presented that investigates the hot tearing susceptibility of an aluminium 6061 semisolid weld. Two key phenomena are considered: excessive deformation of the semisolid weld, initiating a hot tear, and the ability of the semisolid weld to heal the hot tear by circulation of the molten metal. The model consists of two major modules: weld solidification and thermomechanical analysis. 1) By means of a multi-scale model of solidification, the microstructural evolution of the semisolid weld is simulated in 3D. The semisolid structure, which varies as a function of welding parameters, is composed of solidifying grains and a network of micro liquid channels. The weld solidification module is utilized to obtain the solidification shrinkage. The size of the micro liquid channels is used as an indicator to assess the healing ability of the semisolid weld. 2) Using the finite element method, the mechanical interaction between the weld pool and the base metal is simulated to capture the transient force field deforming the semisolid weld. Thermomechanical stresses and shrinkage stresses are both considered in the analysis; the solidification contractions are extracted from the weld solidification module and applied to the deformation simulation as boundary conditions. Such an analysis enables characterization of the potential for excessive deformation of the weld. The outputs of the model are used to study the effect of welding parameters including welding current and speed, and also welding constraint on the hot cracking susceptibility of an aluminium alloy 6061 semisolid weld.

  19. 49 CFR 192.225 - Welding procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding procedures. 192.225 Section 192.225... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.225 Welding procedures. (a) Welding must be performed by a qualified welder in accordance with welding procedures...

  20. 49 CFR 192.225 - Welding procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Welding procedures. 192.225 Section 192.225... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.225 Welding procedures. (a) Welding must be performed by a qualified welder in accordance with welding procedures...

Top