DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.
The US Department of Energy’s most recent commercial energy code compliance evaluation efforts focused on determining a percent compliance rating for states to help them meet requirements under the American Recovery and Reinvestment Act (ARRA) of 2009. That approach included a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. With its binary approach to compliance determination, the previous methodology failed to answer some important questions. In particular, how much energy cost could be saved by better compliance with the commercial energymore » code and what are the relative priorities of code requirements from an energy cost savings perspective? This paper explores an analytical approach and pilot study using a single building type and climate zone to answer those questions.« less
Compliance Verification Paths for Residential and Commercial Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conover, David R.; Makela, Eric J.; Fannin, Jerica D.
2011-10-10
This report looks at different ways to verify energy code compliance and to ensure that the energy efficiency goals of an adopted document are achieved. Conformity assessment is the body of work that ensures compliance, including activities that can ensure residential and commercial buildings satisfy energy codes and standards. This report identifies and discusses conformity-assessment activities and provides guidance for conducting assessments.
The Marriage of Residential Energy Codes and Rating Systems: Conflict Resolution or Just Conflict?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, Zachary T.; Mendon, Vrushali V.
2014-08-21
After three decades of coexistence at a distance, model residential energy codes and residential energy rating systems have come together in the 2015 International Energy Conservation Code. At the October, 2013, International Code Council’s Public Comment Hearing, a new compliance path based on an Energy Rating Index was added to the IECC. Although not specifically named in the code, RESNET’s HERS rating system is the likely candidate Index for most jurisdictions. While HERS has been a mainstay in various beyond-code programs for many years, its direct incorporation into the most popular model energy code raises questions about the equivalence ofmore » a HERS-based compliance path and the traditional IECC performance compliance path, especially because the two approaches use different efficiency metrics, are governed by different simulation rules, and have different scopes with regard to energy impacting house features. A detailed simulation analysis of more than 15,000 house configurations reveals a very large range of HERS Index values that achieve equivalence with the IECC’s performance path. This paper summarizes the results of that analysis and evaluates those results against the specific Energy Rating Index values required by the 2015 IECC. Based on the home characteristics most likely to result in disparities between HERS-based compliance and performance path compliance, potential impacts on the compliance process, state and local adoption of the new code, energy efficiency in the next generation of homes subject to this new code, and future evolution of model code formats are discussed.« less
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Compliance. 434.604 Section 434.604 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.604 Compliance. 604.1 Compliance with this section is...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Compliance. 434.604 Section 434.604 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.604 Compliance. 604.1 Compliance with this section is...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Compliance. 434.604 Section 434.604 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.604 Compliance. 604.1 Compliance with this section is...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Compliance. 434.604 Section 434.604 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.604 Compliance. 604.1 Compliance with this section is...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Compliance. 434.604 Section 434.604 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.604 Compliance. 604.1 Compliance with this section is...
Building Energy Efficiency in India: Compliance Evaluation of Energy Conservation Building Code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Sha; Evans, Meredydd; Delgado, Alison
India is experiencing unprecedented construction boom. The country doubled its floorspace between 2001 and 2005 and is expected to add 35 billion m2 of new buildings by 2050. Buildings account for 35% of total final energy consumption in India today, and building energy use is growing at 8% annually. Studies have shown that carbon policies will have little effect on reducing building energy demand. Chaturvedi et al. predicted that, if there is no specific sectoral policies to curb building energy use, final energy demand of the Indian building sector will grow over five times by the end of this century,more » driven by rapid income and population growth. The growing energy demand in buildings is accompanied by a transition from traditional biomass to commercial fuels, particularly an increase in electricity use. This also leads to a rapid increase in carbon emissions and aggravates power shortage in India. Growth in building energy use poses challenges to the Indian government. To curb energy consumption in buildings, the Indian government issued the Energy Conservation Building Code (ECBC) in 2007, which applies to commercial buildings with a connected load of 100 kW or 120kVA. It is predicted that the implementation of ECBC can help save 25-40% of energy, compared to reference buildings without energy-efficiency measures. However, the impact of ECBC depends on the effectiveness of its enforcement and compliance. Currently, the majority of buildings in India are not ECBC-compliant. The United Nations Development Programme projected that code compliance in India would reach 35% by 2015 and 64% by 2017. Whether the projected targets can be achieved depends on how the code enforcement system is designed and implemented. Although the development of ECBC lies in the hands of the national government – the Bureau of Energy Efficiency under the Ministry of Power, the adoption and implementation of ECBC largely relies on state and local governments. Six years after ECBC’s enactment, only two states and one territory out of 35 Indian states and union territories formally adopted ECBC and six additional states are in the legislative process of approving ECBC. There are several barriers that slow down the process. First, stakeholders, such as architects, developers, and state and local governments, lack awareness of building energy efficiency, and do not have enough capacity and resources to implement ECBC. Second, institution for implementing ECBC is not set up yet; ECBC is not included in local building by-laws or incorporated into the building permit process. Third, there is not a systematic approach to measuring and verifying compliance and energy savings, and thus the market does not have enough confidence in ECBC. Energy codes achieve energy savings only when projects comply with codes, yet only few countries measure compliance consistently and periodic checks often indicate poor compliance in many jurisdictions. China and the U.S. appear to be two countries with comprehensive systems in code enforcement and compliance The United States recently developed methodologies measuring compliance with building energy codes at the state level. China has an annual survey investigating code compliance rate at the design and construction stages in major cities. Like many developing countries, India has only recently begun implementing an energy code and would benefit from international experience on code compliance. In this paper, we examine lessons learned from the U.S. and China on compliance assessment and how India can apply these lessons to develop its own compliance evaluation approach. This paper also provides policy suggestions to national, state, and local governments to improve compliance and speed up ECBC implementation.« less
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Compliance. 434.509 Section 434.509 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.509 Compliance. 509.1If the Design Energy Cost...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Compliance. 434.509 Section 434.509 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.509 Compliance. 509.1 If the Design Energy Cost...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Compliance. 434.509 Section 434.509 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.509 Compliance. 509.1If the Design Energy Cost...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Compliance. 434.509 Section 434.509 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.509 Compliance. 509.1If the Design Energy Cost...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Compliance. 434.509 Section 434.509 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.509 Compliance. 509.1If the Design Energy Cost...
Potential Energy Cost Savings from Increased Commercial Energy Code Compliance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.
2016-08-22
An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed officemore » buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.« less
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Compliance. 434.102 Section 434.102 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Administration and Enforcement-General § 434.102 Compliance. 102.1A covered building must be...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Compliance. 434.102 Section 434.102 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Administration and Enforcement-General § 434.102 Compliance. 102.1A covered building must be...
Preserving Envelope Efficiency in Performance Based Code Compliance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornton, Brian A.; Sullivan, Greg P.; Rosenberg, Michael I.
2015-06-20
The City of Seattle 2012 Energy Code (Seattle 2014), one of the most progressive in the country, is under revision for its 2015 edition. Additionally, city personnel participate in the development of the next generation of the Washington State Energy Code and the International Energy Code. Seattle has pledged carbon neutrality by 2050 including buildings, transportation and other sectors. The United States Department of Energy (DOE), through Pacific Northwest National Laboratory (PNNL) provided technical assistance to Seattle in order to understand the implications of one potential direction for its code development, limiting trade-offs of long-lived building envelope components less stringentmore » than the prescriptive code envelope requirements by using better-than-code but shorter-lived lighting and heating, ventilation, and air-conditioning (HVAC) components through the total building performance modeled energy compliance path. Weaker building envelopes can permanently limit building energy performance even as lighting and HVAC components are upgraded over time, because retrofitting the envelope is less likely and more expensive. Weaker building envelopes may also increase the required size, cost and complexity of HVAC systems and may adversely affect occupant comfort. This report presents the results of this technical assistance. The use of modeled energy code compliance to trade-off envelope components with shorter-lived building components is not unique to Seattle and the lessons and possible solutions described in this report have implications for other jurisdictions and energy codes.« less
An international survey of building energy codes and their implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, Meredydd; Roshchanka, Volha; Graham, Peter
Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy demand from buildings. Access to benefits of building energy codes depends on comprehensive coverage of buildings by type, age, size, andmore » geographic location; an implementation framework that involves a certified agency to inspect construction at critical stages; and independently tested, rated, and labeled building energy materials. Training and supporting tools are another element of successful code implementation, and their role is growing in importance, given the increasing flexibility and complexity of building energy codes. Some countries have also introduced compliance evaluation and compliance checking protocols to improve implementation. This article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vine, E.
1990-11-01
As part of Lawrence Berkeley Laboratory's (LBL) technical assistance to the Sustainable City Project, compliance and enforcement activities related to local and state building codes for existing and new construction were evaluated in two case studies. The analysis of the City of San Francisco's Residential Energy Conservation Ordinance (RECO) showed that a limited, prescriptive energy conservation ordinance for existing residential construction can be enforced relatively easily with little administrative costs, and that compliance with such ordinances can be quite high. Compliance with the code was facilitated by extensive publicity, an informed public concerned with the cost of energy and knowledgeablemore » about energy efficiency, the threat of punishment (Order of Abatement), the use of private inspectors, and training workshops for City and private inspectors. The analysis of California's Title 24 Standards for new residential and commercial construction showed that enforcement of this type of code for many climate zones is more complex and requires extensive administrative support for education and training of inspectors, architects, engineers, and builders. Under this code, prescriptive and performance approaches for compliance are permitted, resulting in the demand for alternative methods of enforcement: technical assistance, plan review, field inspection, and computer analysis. In contrast to existing construction, building design and new materials and construction practices are of critical importance in new construction, creating a need for extensive technical assistance and extensive interaction between enforcement personnel and the building community. Compliance problems associated with building design and installation did occur in both residential and nonresidential buildings. Because statewide codes are enforced by local officials, these problems may increase over time as energy standards change and become more complex and as other standards (eg, health and safety codes) remain a higher priority. The California Energy Commission realizes that code enforcement by itself is insufficient and expects that additional educational and technical assistance efforts (eg, manuals, training programs, and toll-free telephone lines) will ameliorate these problems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vine, E.
1990-11-01
As part of Lawrence Berkeley Laboratory's (LBL) technical assistance to the Sustainable City Project, compliance and enforcement activities related to local and state building codes for existing and new construction were evaluated in two case studies. The analysis of the City of San Francisco's Residential Energy Conservation Ordinance (RECO) showed that a limited, prescriptive energy conservation ordinance for existing residential construction can be enforced relatively easily with little administrative costs, and that compliance with such ordinances can be quite high. Compliance with the code was facilitated by extensive publicity, an informed public concerned with the cost of energy and knowledgeablemore » about energy efficiency, the threat of punishment (Order of Abatement), the use of private inspectors, and training workshops for City and private inspectors. The analysis of California's Title 24 Standards for new residential and commercial construction showed that enforcement of this type of code for many climate zones is more complex and requires extensive administrative support for education and training of inspectors, architects, engineers, and builders. Under this code, prescriptive and performance approaches for compliance are permitted, resulting in the demand for alternative methods of enforcement: technical assistance, plan review, field inspection, and computer analysis. In contrast to existing to construction, building design and new materials and construction practices are of critical importance in new construction, creating a need for extensive technical assistance and extensive interaction between enforcement personnel and the building community. Compliance problems associated with building design and installation did occur in both residential and nonresidential buildings. 12 refs., 5 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dillon, Heather E.; Antonopoulos, Chrissi A.; Solana, Amy E.
As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density permore » unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft{sup 2} of roof area or 0.5 W/ft{sup 2} of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft{sup 2} of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.« less
78 FR 47677 - DOE Activities and Methodology for Assessing Compliance With Building Energy Codes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-06
... construction. Post- construction evaluations were implemented in one study in an effort to reduce these costs... these pilot studies have led to a number of recommendations and potential changes to the DOE methodology... fundamental assumptions and approaches to measuring compliance with building energy codes. This notice...
Reducing EnergyPlus Run Time For Code Compliance Tools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Athalye, Rahul A.; Gowri, Krishnan; Schultz, Robert W.
2014-09-12
Integration of the EnergyPlus ™ simulation engine into performance-based code compliance software raises a concern about simulation run time, which impacts timely feedback of compliance results to the user. EnergyPlus annual simulations for proposed and code baseline building models, and mechanical equipment sizing result in simulation run times beyond acceptable limits. This paper presents a study that compares the results of a shortened simulation time period using 4 weeks of hourly weather data (one per quarter), to an annual simulation using full 52 weeks of hourly weather data. Three representative building types based on DOE Prototype Building Models and threemore » climate zones were used for determining the validity of using a shortened simulation run period. Further sensitivity analysis and run time comparisons were made to evaluate the robustness and run time savings of using this approach. The results of this analysis show that the shortened simulation run period provides compliance index calculations within 1% of those predicted using annual simulation results, and typically saves about 75% of simulation run time.« less
Energy Cost Impact of Non-Residential Energy Code Requirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jian; Hart, Philip R.; Rosenberg, Michael I.
2016-08-22
The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of themore » probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, Michael I.; Hart, Philip R.
2016-02-16
Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI)more » less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, Michael I.; Hart, Philip R.
2016-03-01
Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI)more » less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.« less
10 CFR 434.605 - Standard Calculation Procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...
10 CFR 434.605 - Standard Calculation Procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Occupancy. 434.513 Section 434.513 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.513 Occupancy. 5131Occupancy schedules are...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.510 - Standard calculation procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...
10 CFR 434.605 - Standard Calculation Procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Occupancy. 434.513 Section 434.513 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.513 Occupancy. 5131 Occupancy schedules are...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.605 - Standard Calculation Procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Occupancy. 434.513 Section 434.513 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.513 Occupancy. 5131Occupancy schedules are...
10 CFR 434.510 - Standard calculation procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...
10 CFR 434.605 - Standard Calculation Procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Occupancy. 434.513 Section 434.513 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.513 Occupancy. 5131Occupancy schedules are...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.510 - Standard calculation procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...
10 CFR 434.510 - Standard calculation procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
78 FR 55245 - Activities and Methodology for Assessing Compliance With Building Energy Codes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-10
... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy [Docket No. EERE-2013-BT-BC... Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of reopening of public..., Office of Energy Efficiency and Renewable Energy, Building Technologies Program, Mailstop EE-2J, 1000...
10 CFR 434.602 - Determination of the annual energy budget.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Determination of the annual energy budget. 434.602 Section 434.602 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.602...
10 CFR 434.602 - Determination of the annual energy budget.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Determination of the annual energy budget. 434.602 Section 434.602 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.602...
10 CFR 434.602 - Determination of the annual energy budget.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Determination of the annual energy budget. 434.602 Section 434.602 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.602...
10 CFR 434.603 - Determination of the design energy use.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Determination of the design energy use. 434.603 Section 434.603 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.603...
10 CFR 434.602 - Determination of the annual energy budget.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Determination of the annual energy budget. 434.602 Section 434.602 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.602...
10 CFR 434.602 - Determination of the annual energy budget.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Determination of the annual energy budget. 434.602 Section 434.602 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.602...
10 CFR 434.603 - Determination of the design energy use.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Determination of the design energy use. 434.603 Section 434.603 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.603...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Lighting. 434.514 Section 434.514 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1Interior Lighting Power...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Lighting. 434.514 Section 434.514 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1Interior Lighting Power...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1Receptacle loads and...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1 Receptacle loads and...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Lighting. 434.514 Section 434.514 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1Interior Lighting Power...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1Receptacle loads and...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1Receptacle loads and...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Lighting. 434.514 Section 434.514 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1 Interior Lighting Power...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Lighting. 434.514 Section 434.514 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1Interior Lighting Power...
10 CFR 434.606 - Simulation tool.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Simulation tool. 434.606 Section 434.606 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.606 Simulation tool. 606.1 The criteria...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false General. 434.601 Section 434.601 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.601 General. 601.1 This subpart provides an...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false General. 434.601 Section 434.601 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.601 General. 601.1This subpart provides an...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false General. 434.601 Section 434.601 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.601 General. 601.1This subpart provides an...
10 CFR 434.508 - Determination of the design energy consumption and design energy cost.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Determination of the design energy consumption and design energy cost. 434.508 Section 434.508 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.508 - Determination of the design energy consumption and design energy cost.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Determination of the design energy consumption and design energy cost. 434.508 Section 434.508 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.508 - Determination of the design energy consumption and design energy cost.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Determination of the design energy consumption and design energy cost. 434.508 Section 434.508 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.508 - Determination of the design energy consumption and design energy cost.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Determination of the design energy consumption and design energy cost. 434.508 Section 434.508 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.508 - Determination of the design energy consumption and design energy cost.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Determination of the design energy consumption and design energy cost. 434.508 Section 434.508 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.507 - Calculation procedure and simulation tool.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Calculation procedure and simulation tool. 434.507 Section 434.507 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.507...
10 CFR 434.511 - Orientation and shape.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Orientation and shape. 434.511 Section 434.511 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.511 Orientation and shape. 511.1 The...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.607 - Life cycle cost analysis criteria.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Life cycle cost analysis criteria. 434.607 Section 434.607 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.607 Life cycle cost...
10 CFR 434.518 - Service water heating.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Service water heating. 434.518 Section 434.518 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.518 Service water heating. 518.1The...
10 CFR 434.511 - Orientation and shape.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Orientation and shape. 434.511 Section 434.511 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.511 Orientation and shape. 511.1The...
10 CFR 434.607 - Life cycle cost analysis criteria.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Life cycle cost analysis criteria. 434.607 Section 434.607 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.607 Life cycle cost...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1 The systems...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1The systems...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505.1...
10 CFR 434.607 - Life cycle cost analysis criteria.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Life cycle cost analysis criteria. 434.607 Section 434.607 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.607 Life cycle cost...
10 CFR 434.511 - Orientation and shape.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Orientation and shape. 434.511 Section 434.511 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.511 Orientation and shape. 511.1The...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.511 - Orientation and shape.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Orientation and shape. 434.511 Section 434.511 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.511 Orientation and shape. 511.1The...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1The systems...
10 CFR 434.518 - Service water heating.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Service water heating. 434.518 Section 434.518 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.518 Service water heating. 518.1The...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1The systems...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.502 - Determination of the annual energy cost budget.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Determination of the annual energy cost budget. 434.502 Section 434.502 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.502...
10 CFR 434.502 - Determination of the annual energy cost budget.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Determination of the annual energy cost budget. 434.502 Section 434.502 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.502...
10 CFR 434.502 - Determination of the annual energy cost budget.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Determination of the annual energy cost budget. 434.502 Section 434.502 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.502...
10 CFR 434.502 - Determination of the annual energy cost budget.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Determination of the annual energy cost budget. 434.502 Section 434.502 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.502...
10 CFR 434.502 - Determination of the annual energy cost budget.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Determination of the annual energy cost budget. 434.502 Section 434.502 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.502...
24 CFR 905.312 - Design and construction.
Code of Federal Regulations, 2014 CFR
2014-04-01
... constructed in compliance with: (1) A national building code, such as those developed by the International Code Council or the National Fire Protection Association; and the IECC or ASHRAE 90.1-2010 (both... a successor energy code or standard that has been adopted by HUD pursuant to 42 U.S.C. 12709 or...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, Meredydd; Yu, Sha; Staniszewski, Aaron
Building energy efficiency is an important strategy for reducing greenhouse gas emissions globally. In fact, 55 countries have included building energy efficiency in their Nationally Determined Contributions (NDCs) under the Paris Agreement. This research uses building energy code implementation in six cities across different continents as case studies to assess what it may take for countries to implement the ambitions of their energy efficiency goals. Specifically, we look at the cases of Bogota, Colombia; Da Nang, Vietnam; Eskisehir, Turkey; Mexico City, Mexico; Rajkot, India; and Tshwane, South Africa, all of which are “deep dive” cities under the Sustainable Energy formore » All's Building Efficiency Accelerator. The research focuses on understanding the baseline with existing gaps in implementation and coordination. The methodology used a combination of surveys on code status and interviews with stakeholders at the local and national level, as well as review of published documents. We looked at code development, implementation, and evaluation. The cities are all working to improve implementation, however, the challenges they currently face include gaps in resources, capacity, tools, and institutions to check for compliance. Better coordination between national and local governments could help improve implementation, but that coordination is not yet well established. For example, all six of the cities reported that there was little to no involvement of local stakeholders in development of the national code; only one city reported that it had access to national funding to support code implementation. More robust coordination could better link cities with capacity building and funding for compliance, and ensure that the code reflects local priorities. By understanding gaps in implementation, it can also help in designing more targeted interventions to scale up energy savings.« less
Evans, Meredydd; Yu, Sha; Staniszewski, Aaron; ...
2018-04-17
Building energy efficiency is an important strategy for reducing greenhouse gas emissions globally. In fact, 55 countries have included building energy efficiency in their Nationally Determined Contributions (NDCs) under the Paris Agreement. This research uses building energy code implementation in six cities across different continents as case studies to assess what it may take for countries to implement the ambitions of their energy efficiency goals. Specifically, we look at the cases of Bogota, Colombia; Da Nang, Vietnam; Eskisehir, Turkey; Mexico City, Mexico; Rajkot, India; and Tshwane, South Africa, all of which are “deep dive” cities under the Sustainable Energy formore » All's Building Efficiency Accelerator. The research focuses on understanding the baseline with existing gaps in implementation and coordination. The methodology used a combination of surveys on code status and interviews with stakeholders at the local and national level, as well as review of published documents. We looked at code development, implementation, and evaluation. The cities are all working to improve implementation, however, the challenges they currently face include gaps in resources, capacity, tools, and institutions to check for compliance. Better coordination between national and local governments could help improve implementation, but that coordination is not yet well established. For example, all six of the cities reported that there was little to no involvement of local stakeholders in development of the national code; only one city reported that it had access to national funding to support code implementation. More robust coordination could better link cities with capacity building and funding for compliance, and ensure that the code reflects local priorities. By understanding gaps in implementation, it can also help in designing more targeted interventions to scale up energy savings.« less
An international survey of building energy codes and their implementation
Evans, Meredydd; Roshchanka, Volha; Graham, Peter
2017-08-01
Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy use in buildings. These elements and practices include: comprehensive coverage of buildings by type, age, size, and geographic location; an implementationmore » framework that involves a certified agency to inspect construction at critical stages; and building materials that are independently tested, rated, and labeled. Training and supporting tools are another element of successful code implementation. Some countries have also introduced compliance evaluation studies, which suggested that tightening energy requirements would only be meaningful when also addressing gaps in implementation (Pitt&Sherry, 2014; U.S. DOE, 2016b). Here, this article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less
An international survey of building energy codes and their implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, Meredydd; Roshchanka, Volha; Graham, Peter
Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy use in buildings. These elements and practices include: comprehensive coverage of buildings by type, age, size, and geographic location; an implementationmore » framework that involves a certified agency to inspect construction at critical stages; and building materials that are independently tested, rated, and labeled. Training and supporting tools are another element of successful code implementation. Some countries have also introduced compliance evaluation studies, which suggested that tightening energy requirements would only be meaningful when also addressing gaps in implementation (Pitt&Sherry, 2014; U.S. DOE, 2016b). Here, this article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less
10 CFR 434.506 - Use of the reference building to determine the energy cost budget.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Use of the reference building to determine the energy cost budget. 434.506 Section 434.506 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tan, Qing; Yu, Sha; Evans, Meredydd
2016-05-01
India adopted the Energy Conservation Building Code (ECBC) in 2007. Rajasthan is the first state to make ECBC mandatory at the state level. In collaboration with Malaviya National Institute of Technology (MNIT) Jaipur, Pacific Northwest National Laboratory (PNNL) has been working with Rajasthan to facilitate the implementation of ECBC. This report summarizes milestones made in Rajasthan and PNNL's contribution in institutional set-ups, capacity building, compliance enforcement and pilot building construction.
Impacts of Model Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Athalye, Rahul A.; Sivaraman, Deepak; Elliott, Douglas B.
The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program; this study looked more broadly at overall code impacts. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions atmore » the state level and at aggregated levels. This analysis does not represent all potential savings from energy codes in the U.S. because it excludes several states which have codes which are fundamentally different from the national model energy codes or which do not have state-wide codes. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when buildings comply with the code. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. Delayed adoption of a model code and incomplete compliance with the code’s requirements erode potential savings. The contributions of all three phases are crucial to the overall impact of codes, and are considered in this assessment.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, Michael; Jonlin, Duane; Nadel, Steven
Today’s building energy codes focus on prescriptive requirements for features of buildings that are directly controlled by the design and construction teams and verifiable by municipal inspectors. Although these code requirements have had a significant impact, they fail to influence a large slice of the building energy use pie – including not only miscellaneous plug loads, cooking equipment and commercial/industrial processes, but the maintenance and optimization of the code-mandated systems as well. Currently, code compliance is verified only through the end of construction, and there are no limits or consequences for the actual energy use in an occupied building. Inmore » the future, our suite of energy regulations will likely expand to include building efficiency, energy use or carbon emission budgets over their full life cycle. Intelligent building systems, extensive renewable energy, and a transition from fossil fuel to electric heating systems will likely be required to meet ultra-low-energy targets. This paper lays out the authors’ perspectives on how buildings may evolve over the course of the 21st century and the roles that codes and regulations will play in shaping those buildings of the future.« less
Technical Support Document for Version 3.4.0 of the COMcheck Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan
2007-09-14
COMcheck provides an optional way to demonstrate compliance with commercial and high-rise residential building energy codes. Commercial buildings include all use groups except single family and multifamily not over three stories in height. COMcheck was originally based on ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989) requirements and is intended for use with various codes based on Standard 90.1, including the Codification of ASHRAE/IES Standard 90.1-1989 (90.1-1989 Code) (ASHRAE 1989a, 1993b) and ASHRAE/IESNA Standard 90.1-1999 (Standard 90.1-1999). This includes jurisdictions that have adopted the 90.1-1989 Code, Standard 90.1-1989, Standard 90.1-1999, or their own code based on one of these. We view Standard 90.1-1989more » and the 90.1-1989 Code as having equivalent technical content and have used both as source documents in developing COMcheck. This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards.« less
Increasing Flexibility in Energy Code Compliance: Performance Packages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Philip R.; Rosenberg, Michael I.
Energy codes and standards have provided significant increases in building efficiency over the last 38 years, since the first national energy code was published in late 1975. The most commonly used path in energy codes, the prescriptive path, appears to be reaching a point of diminishing returns. As the code matures, the prescriptive path becomes more complicated, and also more restrictive. It is likely that an approach that considers the building as an integrated system will be necessary to achieve the next real gains in building efficiency. Performance code paths are increasing in popularity; however, there remains a significant designmore » team overhead in following the performance path, especially for smaller buildings. This paper focuses on development of one alternative format, prescriptive packages. A method to develop building-specific prescriptive packages is reviewed based on a multiple runs of prototypical building models that are used to develop parametric decision analysis to determines a set of packages with equivalent energy performance. The approach is designed to be cost-effective and flexible for the design team while achieving a desired level of energy efficiency performance. A demonstration of the approach based on mid-sized office buildings with two HVAC system types is shown along with a discussion of potential applicability in the energy code process.« less
Marine Sciences Laboratory Radionuclide Air Emissions Report for Calendar Year 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.; Barnett, J. Matthew; Ballinger, Marcel Y.
2014-05-01
The U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest Site Office (PNSO) has oversight and stewardship duties associated with the Pacific Northwest National Laboratory (PNNL) Marine Sciences Laboratory (MSL) located on Battelle Land – Sequim (Sequim). This report is prepared to document compliance with the Code of Federal Regulations (CFR), Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (NESHAP), Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code (WAC) Chapter 246-247, “Radiation Protection–Air Emissions.” The EDE to the Sequimmore » MEI due to routine operations in 2013 was 5E-05 mrem (5E-07 mSv). No non-routine emissions occurred in 2013. The MSL is in compliance with the federal and state 10 mrem/yr standard.« less
Marine Sciences Laboratory Radionuclide Air Emissions Report for Calendar Year 2014
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.; Barnett, J. Matthew
2015-05-04
The U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest Site Office (PNSO) has oversight and stewardship duties associated with the Pacific Northwest National Laboratory (PNNL) Marine Sciences Laboratory (MSL) located on Battelle Land – Sequim.This report is prepared to document compliance with the Code of Federal Regulations (CFR), Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (NESHAP), Subpart H, ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code (WAC) Chapter 246-247, “Radiation Protection–Air Emissions.'' The EDE to the MSL MEI duemore » to routine operations in 2014 was 9E-05 mrem (9E-07 mSv). No non-routine emissions occurred in 2014. The MSL is in compliance with the federal and state 10 mrem/yr standard.« less
Romero-Fernández, Ma Mar; Royo-Bordonada, Miguel Angel; Rodríguez-Artalejo, Fernando
2010-07-01
To evaluate the level of compliance with the PAOS Code (Publicidad, Actividad, Obesidad y Salud), which establishes standards for the self-regulation of food marketing aimed at minors, in television advertising by food and beverage companies that have agreed to abide by the Code. The study sample consisted of food and beverage advertisements targeting children during 80 h of programming by four Spanish television networks. The level of compliance with each standard of the PAOS Code was classified into three categories: 'compliance', 'non-compliance' and 'uncertain compliance'. Overall, an advertisement was considered compliant with the PAOS Code if it met all the standards; non-compliant if it contravened one or more standards; and uncertain in all other cases. Of a total of 203 television advertisements from companies that agreed to the PAOS Code, the overall prevalence of non-compliance was 49.3% (v. 50.8% among those that did not agree to the code), with 20.7% of advertisements considered of uncertain compliance. Non-compliance was more frequent on Saturdays, in longer advertisements, in advertisements containing promotions or dairy products, and for advertisements from companies of French or US origin. Non-compliance with the PAOS Code was very high and was similar for companies that did and did not agree to the Code, casting doubt on the Code's effectiveness and oversight system. It seems the time has come to commit to statutory regulations that reduce the negative impact of advertising on children's diets, as demanded by public health experts and consumer associations.
Technical Support Document for Version 3.6.1 of the COMcheck Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan
2009-09-29
This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards.
Technical Support Document for Version 3.9.0 of the COMcheck Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan
2011-09-01
COMcheck provides an optional way to demonstrate compliance with commercial and high-rise residential building energy codes. Commercial buildings include all use groups except single family and multifamily not over three stories in height. COMcheck was originally based on ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989) requirements and is intended for use with various codes based on Standard 90.1, including the Codification of ASHRAE/IES Standard 90.1-1989 (90.1-1989 Code) (ASHRAE 1989a, 1993b) and ASHRAE/IESNA Standard 90.1-1999 (Standard 90.1-1999). This includes jurisdictions that have adopted the 90.1-1989 Code, Standard 90.1-1989, Standard 90.1-1999, or their own code based on one of these. We view Standard 90.1-1989more » and the 90.1-1989 Code as having equivalent technical content and have used both as source documents in developing COMcheck. This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards. Beginning with COMcheck version 3.8.0, support for 90.1-1989, 90.1-1999, and the 1998 IECC are no longer included, but those sections remain in this document for reference purposes.« less
Technical Support Document for Version 3.9.1 of the COMcheck Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan
2012-09-01
COMcheck provides an optional way to demonstrate compliance with commercial and high-rise residential building energy codes. Commercial buildings include all use groups except single family and multifamily not over three stories in height. COMcheck was originally based on ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989) requirements and is intended for use with various codes based on Standard 90.1, including the Codification of ASHRAE/IES Standard 90.1-1989 (90.1-1989 Code) (ASHRAE 1989a, 1993b) and ASHRAE/IESNA Standard 90.1-1999 (Standard 90.1-1999). This includes jurisdictions that have adopted the 90.1-1989 Code, Standard 90.1-1989, Standard 90.1-1999, or their own code based on one of these. We view Standard 90.1-1989more » and the 90.1-1989 Code as having equivalent technical content and have used both as source documents in developing COMcheck. This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards. Beginning with COMcheck version 3.8.0, support for 90.1-1989, 90.1-1999, and the 1998 IECC and version 3.9.0 support for 2000 and 2001 IECC are no longer included, but those sections remain in this document for reference purposes.« less
7 CFR 1724.50 - Compliance with National Electrical Safety Code (NESC).
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 11 2013-01-01 2013-01-01 false Compliance with National Electrical Safety Code (NESC... UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES AND DESIGN POLICIES AND PROCEDURES Electric System Design § 1724.50 Compliance with National Electrical Safety Code...
7 CFR 1724.50 - Compliance with National Electrical Safety Code (NESC).
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 11 2010-01-01 2010-01-01 false Compliance with National Electrical Safety Code (NESC... UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES AND DESIGN POLICIES AND PROCEDURES Electric System Design § 1724.50 Compliance with National Electrical Safety Code...
7 CFR 1724.50 - Compliance with National Electrical Safety Code (NESC).
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 11 2011-01-01 2011-01-01 false Compliance with National Electrical Safety Code (NESC... UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES AND DESIGN POLICIES AND PROCEDURES Electric System Design § 1724.50 Compliance with National Electrical Safety Code...
7 CFR 1724.50 - Compliance with National Electrical Safety Code (NESC).
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 11 2012-01-01 2012-01-01 false Compliance with National Electrical Safety Code (NESC... UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES AND DESIGN POLICIES AND PROCEDURES Electric System Design § 1724.50 Compliance with National Electrical Safety Code...
7 CFR 1724.50 - Compliance with National Electrical Safety Code (NESC).
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 11 2014-01-01 2014-01-01 false Compliance with National Electrical Safety Code (NESC... UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES AND DESIGN POLICIES AND PROCEDURES Electric System Design § 1724.50 Compliance with National Electrical Safety Code...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evelo, Stacie
This report provides a summary of the radionuclide releases from the United States (U.S.) Department of Energy (DOE) National Nuclear Security Administration facilities at Sandia National Laboratories, New Mexico (SNL/NM) during Calendar Year (CY) 2015, including the data, calculations, and supporting documentation for demonstrating compliance with 40 Code of Federal Regulation (CFR) 61.
ERIC Educational Resources Information Center
Strickland, Gary
2001-01-01
Explains how changes in school design in the last 10 years have caused heating, ventilation, and cooling system (HVAC) designers to reexamine their choice of classroom unit ventilators (UV). The influence of indoor lighting systems, insulation, indoor air quality, energy code compliance, and HVAC system design on UV decision making are also…
77 FR 43645 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-25
...] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 of the Code of Federal... Transportation (CSX), has petitioned the Federal Railroad Administration (FRA) for a waiver of compliance from... Compliance. [FR Doc. 2012-18081 Filed 7-24-12; 8:45 am] BILLING CODE 4910-06-P ...
Code of Federal Regulations, 2012 CFR
2012-10-01
... evidence that the structure was not in compliance with the building code at the time it was built; and (2... evidence that the structure was not in compliance with the building code at the time it was built; and (2... structure and found no evidence that the structure was not in compliance with the building code at the time...
Code of Federal Regulations, 2014 CFR
2014-10-01
... evidence that the structure was not in compliance with the building code at the time it was built; and (2... evidence that the structure was not in compliance with the building code at the time it was built; and (2... structure and found no evidence that the structure was not in compliance with the building code at the time...
Code of Federal Regulations, 2011 CFR
2011-10-01
... evidence that the structure was not in compliance with the building code at the time it was built; and (2... evidence that the structure was not in compliance with the building code at the time it was built; and (2... structure and found no evidence that the structure was not in compliance with the building code at the time...
Code of Federal Regulations, 2013 CFR
2013-10-01
... evidence that the structure was not in compliance with the building code at the time it was built; and (2... evidence that the structure was not in compliance with the building code at the time it was built; and (2... structure and found no evidence that the structure was not in compliance with the building code at the time...
Code of Federal Regulations, 2010 CFR
2010-10-01
... evidence that the structure was not in compliance with the building code at the time it was built; and (2... evidence that the structure was not in compliance with the building code at the time it was built; and (2... structure and found no evidence that the structure was not in compliance with the building code at the time...
Energy Storage System Safety: Plan Review and Inspection Checklist
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cole, Pam C.; Conover, David R.
Codes, standards, and regulations (CSR) governing the design, construction, installation, commissioning, and operation of the built environment are intended to protect the public health, safety, and welfare. While these documents change over time to address new technology and new safety challenges, there is generally some lag time between the introduction of a technology into the market and the time it is specifically covered in model codes and standards developed in the voluntary sector. After their development, there is also a timeframe of at least a year or two until the codes and standards are adopted. Until existing model codes andmore » standards are updated or new ones are developed and then adopted, one seeking to deploy energy storage technologies or needing to verify the safety of an installation may be challenged in trying to apply currently implemented CSRs to an energy storage system (ESS). The Energy Storage System Guide for Compliance with Safety Codes and Standards1 (CG), developed in June 2016, is intended to help address the acceptability of the design and construction of stationary ESSs, their component parts, and the siting, installation, commissioning, operations, maintenance, and repair/renovation of ESS within the built environment.« less
ERIC Educational Resources Information Center
Morris, Suzanne E.
2010-01-01
This paper provides a review of institutional authorship policies as required by the "Australian Code for the Responsible Conduct of Research" (the "Code") (National Health and Medical Research Council (NHMRC), the Australian Research Council (ARC) & Universities Australia (UA) 2007), and assesses them for Code compliance.…
Marine Sciences Laboratory Radionuclide Air Emissions Report for Calendar Year 2015
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.; Barnett, J. Matthew
2016-05-05
The U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest Site Office has oversight and stewardship duties associated with the Pacific Northwest National Laboratory Marine Sciences Laboratory located on Battelle Land – Sequim. This report is prepared to document compliance with the 40 CFR Part 61, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code . The EDE to the MSL MEI due to routine operations in 2015 was 1.1E-04 mrem (1.1E-06 mSv). No non-routine emissions occurred in 2015. The MSL is in compliance with the federalmore » and state 10 mrem/yr standard.« less
Alternative Formats to Achieve More Efficient Energy Codes for Commercial Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conover, David R.; Rosenberg, Michael I.; Halverson, Mark A.
2013-01-26
This paper identifies and examines several formats or structures that could be used to create the next generation of more efficient energy codes and standards for commercial buildings. Pacific Northwest National Laboratory (PNNL) is funded by the U.S. Department of Energy’s Building Energy Codes Program (BECP) to provide technical support to the development of ANSI/ASHRAE/IES Standard 90.1. While the majority of PNNL’s ASHRAE Standard 90.1 support focuses on developing and evaluating new requirements, a portion of its work involves consideration of the format of energy standards. In its current working plan, the ASHRAE 90.1 committee has approved an energy goalmore » of 50% improvement in Standard 90.1-2013 relative to Standard 90.1-2004, and will likely be considering higher improvement targets for future versions of the standard. To cost-effectively achieve the 50% goal in manner that can gain stakeholder consensus, formats other than prescriptive must be considered. Alternative formats that include reducing the reliance on prescriptive requirements may make it easier to achieve these aggressive efficiency levels in new codes and standards. The focus on energy code and standard formats is meant to explore approaches to presenting the criteria that will foster compliance, enhance verification, and stimulate innovation while saving energy in buildings. New formats may also make it easier for building designers and owners to design and build the levels of efficiency called for in the new codes and standards. This paper examines a number of potential formats and structures, including prescriptive, performance-based (with sub-formats of performance equivalency and performance targets), capacity constraint-based, and outcome-based. The paper also discusses the pros and cons of each format from the viewpoint of code users and of code enforcers.« less
Energy Efficiency Building Code for Commercial Buildings in Sri Lanka
DOE Office of Scientific and Technical Information (OSTI.GOV)
Busch, John; Greenberg, Steve; Rubinstein, Francis
2000-09-30
1.1.1 To encourage energy efficient design or retrofit of commercial buildings so that they may be constructed, operated, and maintained in a manner that reduces the use of energy without constraining the building function, the comfort, health, or the productivity of the occupants and with appropriate regard for economic considerations. 1.1.2 To provide criterion and minimum standards for energy efficiency in the design or retrofit of commercial buildings and provide methods for determining compliance with them. 1.1.3 To encourage energy efficient designs that exceed these criterion and minimum standards.
León-Flández, K; Rico-Gómez, A; Moya-Geromin, M Á; Romero-Fernández, M; Bosqued-Estefania, M J; Damián, J; López-Jurado, L; Royo-Bordonada, M Á
2017-09-01
To evaluate compliance levels with the Spanish Code of self-regulation of food and drinks advertising directed at children under the age of 12 years (Publicidad, Actividad, Obesidad, Salud [PAOS] Code) in 2012; and compare these against the figures for 2008. Cross-sectional study. Television advertisements of food and drinks (AFD) were recorded over 7 days in 2012 (8am-midnight) of five Spanish channels popular to children. AFD were classified as core (nutrient-rich/low-calorie products), non-core (nutrient-poor/rich-calorie products) or miscellaneous. Compliance with each standard of the PAOS Code was evaluated. AFD were deemed to be fully compliant when it met all the standards. Two thousand five hundred and eighty-two AFDs came within the purview of the PAOS Code. Some of the standards that registered the highest levels of non-compliance were those regulating the suitability of the information presented (79.4%) and those prohibiting the use of characters popular with children (25%). Overall non-compliance with the Code was greater in 2012 than in 2008 (88.3% vs 49.3%). Non-compliance was highest for advertisements screened on children's/youth channels (92.3% vs. 81.5%; P < 0.001) and for those aired outside the enhanced protection time slot (89.3% vs. 86%; P = 0.015). Non-compliance with the PAOS Code is higher than for 2008. Given the lack of effectiveness of self-regulation, a statutory system should be adopted to ban AFD directed at minors, or at least restrict it to healthy products. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
A Stable Whole Building Performance Method for Standard 90.1-Part II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, Michael I.; Eley, Charles
2016-06-01
In May of 2013 we introduced a new approach for compliance with Standard 90.1 that was under development based on the Performance Rating Method of Appendix G to Standard 90.11. Since then, the approach has been finalized through Addendum BM to Standard 90.1-2013 and will be published in the 2016 edition of the Standard. In the meantime, ASHRAE has published an advanced copy of Appendix G including Addendum BM and several other addenda so that software developers and energy program administrators can get a preview of what is coming in the 2016 edition of the Standard2. This article is anmore » update on Addendum BM, summarizes changes made to the original concept as introduced in May of 2013, and provides an approach for developing performance targets for code compliance and beyond code programs.« less
Implementing energy standards for motors and buildings in the Philippines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiel, S.; Busch, J.; Sanchez, C.
1998-07-01
The Philippines' master plan for energy makes cornerstones of energy standards for appliances, buildings, and motors in their energy efficiency effort. Significant progress has been made in implementing appliance standards for some products, but has lagged for others. This has been partly because the resources allocated have dictated a cautious deliberate approach. Products where there has been a lack of information about the respective markets have received lowest priority. Motors fall in this latter category. In their development of building codes, the Philippine government has also taken a cautious deliberate approach and is just now attending to the compliance ofmore » a commercial building energy performance standard that was enacted into law in 1994. This paper describes the results of recent new buildings and motor market assessments carried out in the Philippines, a survey of building energy code implementation in other countries, and how these products are being used to further implementation of energy standards in the Philippines. Lessons for other countries are drawn from this experience.« less
29 CFR 1910.35 - Compliance with NFPA 101-2000, Life Safety Code.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 5 2011-07-01 2011-07-01 false Compliance with NFPA 101-2000, Life Safety Code. 1910.35 Section 1910.35 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Means of Egress § 1910.35 Compliance...
Code of Federal Regulations, 2010 CFR
2010-10-01
... compliance of health and safety codes during construction projects being performed by a Self-Governance Tribe... SERVICES TRIBAL SELF-GOVERNANCE Construction Roles of the Secretary in Establishing and Implementing Construction Project Agreements § 137.368 Is the Secretary responsible for oversight and compliance of health...
Haiek, Laura N
2012-08-01
Since 2001, Quebec's ministry of health and social services has prioritized implementation of the Baby-Friendly Initiative (BFI), which includes the original hospital initiative and its expansion to community services. The objective was to document across the province compliance with the BFI's Ten Steps to Successful Breastfeeding in hospitals, Seven Point Plan in community health centers (CHCs), and International Code of Marketing of Breast-Milk Substitutes (Code). Using managers/staff, mothers, and observers, the author measured the extent of implementation of indicators formulated for each step/point and the Code, based on the revised WHO/UNICEF recommendations. Mean compliance scores in Quebec were 3.13 for 140 CHCs (range, 0 to 7) and 4.54 for 60 hospitals/birthing centers (range, 0 to 10). The mean compliance score for the Code was 0.69 for both CHCs and hospitals/birthing centers. The evaluation documented marked variations in implementation level for each of the steps/points and the Code. Also, managers/staff, mothers, and observers differed in their report of BFI compliance for most steps/points and the Code. Facilities that had applied for or obtained BFI designation demonstrated higher compliance with the BFI than those that had not. Results disseminated to participating organizations allowed comparisons on a regional/provincial perspective and in relation to BFI-designated facilities. Furthermore, this first portrait of BFI compliance in Quebec provided provincial, regional, and local health authorities with valuable information that can be used to bring about policy and organizational changes to achieve the international standards required for Baby-Friendly certification.
Campbell, J P; Gratton, M C; Salomone, J A; Lindholm, D J; Watson, W A
1994-01-01
In some emergency medical services (EMS) system designs, response time intervals are mandated with monetary penalties for noncompliance. These times are set with the goal of providing rapid, definitive patient care. The time interval of vehicle at scene-to-patient access (VSPA) has been measured, but its effect on response time interval compliance has not been determined. To determine the effect of the VSPA interval on the mandated code 1 (< 9 min) and code 2 (< 13 min) response time interval compliance in an urban, public-utility model system. A prospective, observational study used independent third-party riders to collect the VSPA interval for emergency life-threatening (code 1) and emergency nonlife-threatening (code 2) calls. The VSPA interval was added to the 9-1-1 call-to-dispatch and vehicle dispatch-to-scene intervals to determine the total time interval from call received until paramedic access to the patient (9-1-1 call-to-patient access). Compliance with the mandated response time intervals was determined using the traditional time intervals (9-1-1 call-to-scene) plus the VSPA time intervals (9-1-1 call-to-patient access). Chi-square was used to determine statistical significance. Of the 216 observed calls, 198 were matched to the traditional time intervals. Sixty-three were code 1, and 135 were code 2. Of the code 1 calls, 90.5% were compliant using 9-1-1 call-to-scene intervals dropping to 63.5% using 9-1-1 call-to-patient access intervals (p < 0.0005). Of the code 2 calls, 94.1% were compliant using 9-1-1 call-to-scene intervals. Compliance decreased to 83.7% using 9-1-1 call-to-patient access intervals (p = 0.012). The addition of the VSPA interval to the traditional time intervals impacts system response time compliance. Using 9-1-1 call-to-scene compliance as a basis for measuring system performance underestimates the time for the delivery of definitive care. This must be considered when response time interval compliances are defined.
Sequim Site Radionuclide Air Emissions Report for Calendar Year 2012
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.; Barnett, J. Matthew; Gervais, Todd L.
2013-04-01
This report is prepared to document compliance with the Code of Federal Regulations (CFR), Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (NESHAP), Subpart H, National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities and ashington Administrative Code (WAC) Chapter 246-247, Radiation Protection Air Emissions. This report meets the calendar year 2012 Sequim Site annual reporting requirement for its operations as a privately-owned facility as well as its federally-contracted status that began in October 2012. Compliance is indicated by comparing the estimated dose to the maximally exposedmore » individual (MEI) with the 10 mrem/yr Environmental Protection Agency (EPA) standard. The MSL contains only sources classified as fugitive emissions. Despite the fact that the regulations are intended for application to point source emissions, fugitive emissions are included with regard to complying with the EPA standard. The dose to the Sequim Site MEI due to routine operations in 2012 was 9E-06 mrem (9E-08 mSv). No non-routine emissions occurred in 2012. The MSL is in compliance with the federal and state 10 mrem/yr standard.« less
KilBride, A L; Mason, S A; Honeyman, P C; Pritchard, D G; Hepple, S; Green, L E
2012-02-11
Animal health (AH) defines the outcome of their inspections of livestock holdings as full compliance with the legislation and welfare code (A), compliance with the legislation but not the code (B), non-compliance with legislation but no pain, distress or suffering obvious in the animals (C) or evidence of unnecessary pain or unnecessary distress (D). The aim of the present study was to investigate whether membership of farm assurance or organic certification schemes was associated with compliance with animal welfare legislation as inspected by AH. Participating schemes provided details of their members, past and present, and these records were matched against inspection data from AH. Multivariable multilevel logistic binomial models were built to investigate the association between compliance with legislation and membership of a farm assurance/organic scheme. The percentage of inspections coded A, B, C or D was 37.1, 35.6, 20.2 and 7.1 per cent, respectively. Once adjusted for year, country, enterprise, herd size and reason for inspection, there was a pattern of significantly reduced risk of codes C and D compared with A and B, in certified enterprises compared with the enterprises that were not known to be certified in all species.
Funduluka, P; Bosomprah, S; Chilengi, R; Mugode, R H; Bwembya, P A; Mudenda, B
2018-03-01
We sought to assess the level of non-compliance with the International Code of Marketing breast-milk substitutes (BMS) and/or Statutory Instrument (SI) Number 48 of 2006 of the Laws of Zambia in two suburbs, Kalingalinga and Chelstone, in Zambia. This was a cross sectional survey. Shop owners (80), health workers (8) and mothers (214) were interviewed. BMS labels and advertisements (62) were observed. The primary outcome was mean non-compliance defined as the number of article violations divided by the total 'obtainable' violations. The score ranges from 0 to 1 with 0 representing no violations in all the articles and one representing violations in all the articles. A total of 62 BMS were assessed. The mean non-compliance score by manufacturers in terms of violations in labelling of BMS was 0.33 (SD = 0.28; 95% CI: 0.26, 0.40). These violations were mainly due to labels containing pictures or graphics representing an infant. 80 shops were also assessed with mean non-compliance score in respect of violations in tie-in-sales, special display, and contact with mothers at the shop estimated as 0.14 (SD = 0.14; 95% CI: 0.11, 0.18). Non-compliance with the Code and/or the local SI is high after 10 years of domesticating the Code.
DOT National Transportation Integrated Search
1994-03-15
The purpose of this Circular is to advise owners and operators of U.S. flag merchant vessels regarding voluntary compliance with the International Management Code for the Safe Operation of Ships and for Pollution Prevention.
Development of Pflotran Code for Waste Isolation Pilot Plant Performance Assessment
NASA Astrophysics Data System (ADS)
Zeitler, T.; Day, B. A.; Frederick, J.; Hammond, G. E.; Kim, S.; Sarathi, R.; Stein, E.
2017-12-01
The Waste Isolation Pilot Plant (WIPP) has been developed by the U.S. Department of Energy (DOE) for the geologic (deep underground) disposal of transuranic (TRU) waste. Containment of TRU waste at the WIPP is regulated by the U.S. Environmental Protection Agency (EPA). The DOE demonstrates compliance with the containment requirements by means of performance assessment (PA) calculations. WIPP PA calculations estimate the probability and consequence of potential radionuclide releases from the repository to the accessible environment for a regulatory period of 10,000 years after facility closure. The long-term performance of the repository is assessed using a suite of sophisticated computational codes. There is a current effort to enhance WIPP PA capabilities through the further development of the PFLOTRAN software, a state-of-the-art massively parallel subsurface flow and reactive transport code. Benchmark testing of the individual WIPP-specific process models implemented in PFLOTRAN (e.g., gas generation, chemistry, creep closure, actinide transport, and waste form) has been performed, including results comparisons for PFLOTRAN and existing WIPP PA codes. Additionally, enhancements to the subsurface hydrologic flow mode have been made. Repository-scale testing has also been performed for the modified PFLTORAN code and detailed results will be presented. Ultimately, improvements to the current computational environment will result in greater detail and flexibility in the repository model due to a move from a two-dimensional calculation grid to a three-dimensional representation. The result of the effort will be a state-of-the-art subsurface flow and transport capability that will serve WIPP PA into the future for use in compliance recertification applications (CRAs) submitted to the EPA. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525. This research is funded by WIPP programs administered by the Office of Environmental Management (EM) of the U.S. Department of Energy.SAND2017-8198A.
Building an effective corporate compliance plan.
Ryan, E
1997-09-01
Corporate compliance plans are essential for healthcare organizations to cope with, and perhaps even stave off, investigations arising from allegations of illegal business practices. Initial development and implementation of a corporate compliance plan can be facilitated through four steps: determining the content of the code of conduct, determining how the code will be distributed, assigning responsibility for implementing the plan, and appointing a compliance task force to guide the implementation process. Special attention should be paid to education requirements of the United States Sentencing Guidelines to see that all employees understand and can apply provisions of the plan.
Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klocke, S.; Faakye, O.; Puttagunta, S.
2014-10-01
While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-risemore » multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-11-01
While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-risemore » multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.« less
Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klocke, S.; Faakye, O.; Puttagunta, S.
2014-10-01
While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-risemore » multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.« less
78 FR 46681 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-01
...] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 Code of Federal Regulations (CFR... compliance from certain provisions of the Federal railroad safety regulations contained at 49 CFR Part 214... all work for compliance with the requirements of the protection procedures and would ensure that all...
76 FR 38456 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
...] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 of the Code of Federal... Administration (FRA) for a waiver of compliance from certain provisions of the Federal railroad safety...- 0048. TriMet has petitioned FRA for a waiver of compliance from certain provisions of the Federal...
76 FR 38453 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
...] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 of the Code of Federal... compliance from certain provisions of the Federal railroad safety regulations contained at 49 CFR Parts 215... waiver of compliance from certain provisions of the Railroad Freight Car Safety Standards, 49 CFR 215.303...
76 FR 38454 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
...] Petition for Waiver of Compliance In accordance with part 211 of Title 49 of the Code of Federal... of compliance from certain provisions of the Federal railroad safety regulations contained at 49 CFR... a waiver of compliance from the Railroad Freight Car Safety Standards, 49 CFR 215.303, which...
76 FR 39977 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-07
...] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 of the Code of Federal... compliance from certain provisions of the Federal railroad safety regulations contained at 49 CFR 215.303... waiver of compliance from certain provisions of the Railroad Freight Car Safety Standards, 49 CFR 215.303...
78 FR 46680 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-01
...] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 Code of Federal Regulations (CFR... Administration (FRA) for a waiver of compliance from certain provisions of the Federal railroad safety.... Specifically, AAR seeks a waiver of compliance from Part 232, Appendix B, Part 232 Prior to May 31, 2001 as...
78 FR 28284 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-14
...] Petition for Waiver of Compliance In accordance with part 211 of Title 49 Code of Federal Regulations (CFR... extension of a waiver of compliance from certain provisions of the Federal railroad safety regulations... compliance from the safety glazing provisions of 49 CFR 223.9(a) and from the requirements of 49 CFR 231.30(c...
77 FR 6171 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-07
...] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 of the Code of Federal... request for a waiver of compliance from certain requirements of its safety standards. In a letter dated... permanent waiver of compliance for one switching locomotive (HVRM 11) from the requirements of 49 CFR part...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-11-01
While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient; the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While thismore » air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Building America team Consortium for Advanced Residential Building's (CARB) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in three multifamily buildings.« less
78 FR 21705 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-11
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2012-0097] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 Code of Federal Regulations (CFR... Federal Railroad Administration (FRA) for a waiver of compliance from certain [[Page 21706
78 FR 28283 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-14
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2013-0031] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 Code of Federal Regulations (CFR... for a waiver of compliance from certain provisions of the Federal railroad safety regulations...
1994-06-01
and Wildlife Service, began research on the Environmental Compliance Assessment and Management Program (ECAMP). The concept was to combine Code of ... The number of environmental laws and regulations have continued to grow in the United States and worldwide, making compliance with these regulations...Service has adopted an environmental compliance program that identifies compliance problems before they are cited as violations by the U.S
Forsyth, Stewart
2013-06-01
Infant feeding policy and practice continues to be a contentious area of global health care. The infant formula industry is widely considered to be the bête noire with frequent claims that they adopt marketing and sales practices that are not compliant with the WHO Code. However, failure to resolve these issues over three decades suggests that there may be wider systemic failings. Review of published papers, commentaries and reports relating to the implementation and governance of the WHO Code with specific reference to issues of non-compliance. The analysis set out in this paper indicates that there are systemic failings at all levels of the implementation and monitoring process including the failure of WHO to successfully 'urge' governments to implement the Code in its entirety; a lack of political will by Member States to implement and monitor the Code and a lack of formal and transparent governance structures. Non-compliance with the WHO Code is not confined to the infant formula industry and several actions are identified, including the need to address issues of partnership working and the establishment of governance systems that are robust, independent and transparent.
77 FR 25783 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-01
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2012-0034] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 Code of Federal Regulations (CFR..., Iowa (City), has petitioned the Federal Railroad Administration (FRA) for a waiver of compliance from...
77 FR 25228 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-27
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2012-0030] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 Code of Federal Regulations (CFR..., CA (City), has petitioned the Federal Railroad Administration (FRA) for a waiver of compliance from...
78 FR 46679 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-01
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2013-0057] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 of the Code of Federal... of compliance from certain provisions of the Federal railroad safety regulations contained at 49 CFR...
76 FR 38453 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [ Docket Number FRA-2011-0049] Petition for Waiver of Compliance In accordance with part 211 of Title 49 of the Code of Federal... railroads has petitioned the Federal Railroad Administration (FRA) for a waiver of compliance from certain...
75 FR 82140 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-29
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration Petition for Waiver of Compliance In accordance with Title 49 Code of Federal Regulations (CFR) Part 211, notice is hereby given that the Federal Railroad Administration (FRA) has received a request for a waiver of compliance from certain requirements...
77 FR 25228 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-27
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2012-0031] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 Code of Federal Regulations (CFR... Sacramento, CA (City), has petitioned the Federal Railroad Administration (FRA) for a waiver of compliance...
76 FR 21096 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-14
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2010-0152] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 of the Code of Federal... initial boundaries, see FRA's Notice of Petition for Waiver of Compliance published on November 2, 2010...
78 FR 28283 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-14
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2013-0006] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 Code of Federal Regulations (CFR... Company (PICK) has petitioned the Federal Railroad Administration (FRA) for a waiver of compliance from...
76 FR 38455 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2006-24216] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 of the Code of Federal... waiver of compliance from certain provisions of the Federal railroad safety regulations contained at 49...
77 FR 43645 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-25
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2012-0052] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 of the Code of Federal... (FRA) for a waiver of compliance from certain Federal hours of service requirements for train employees...
10 CFR 490.802 - Eligibility for alternative compliance waiver.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Eligibility for alternative compliance waiver. 490.802 Section 490.802 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490.802 Eligibility for alternative compliance waiver. Any State subject to subpart C...
10 CFR 490.802 - Eligibility for alternative compliance waiver.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Eligibility for alternative compliance waiver. 490.802 Section 490.802 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490.802 Eligibility for alternative compliance waiver. Any State subject to subpart C...
10 CFR 490.802 - Eligibility for alternative compliance waiver.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Eligibility for alternative compliance waiver. 490.802 Section 490.802 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490.802 Eligibility for alternative compliance waiver. Any State subject to subpart C...
10 CFR 490.802 - Eligibility for alternative compliance waiver.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Eligibility for alternative compliance waiver. 490.802 Section 490.802 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490.802 Eligibility for alternative compliance waiver. Any State subject to subpart C...
10 CFR 490.802 - Eligibility for alternative compliance waiver.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Eligibility for alternative compliance waiver. 490.802 Section 490.802 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490.802 Eligibility for alternative compliance waiver. Any State subject to subpart C...
76 FR 38455 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Numbers FRA-2003-14565 and FRA-2006-24216] Petition for Waiver of Compliance In accordance with part 211 of Title 49 of the Code... Administration (FRA) for a waiver of compliance from certain provisions of the Federal railroad safety...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Compliance. 850.13 Section 850.13 Energy DEPARTMENT OF ENERGY CHRONIC BERYLLIUM DISEASE PREVENTION PROGRAM Administrative Requirements § 850.13 Compliance. (a) The responsible employer must conduct activities in compliance with its CBDPP. (b) The responsible...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Compliance. 850.13 Section 850.13 Energy DEPARTMENT OF ENERGY CHRONIC BERYLLIUM DISEASE PREVENTION PROGRAM Administrative Requirements § 850.13 Compliance. (a) The responsible employer must conduct activities in compliance with its CBDPP. (b) The responsible...
75 FR 27182 - Energy Conservation Program: Web-Based Compliance and Certification Management System
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-14
... Conservation Program: Web-Based Compliance and Certification Management System AGENCY: Office of Energy... certification reports to the Department of Energy (DOE) through an electronic Web-based tool, the Compliance and... following means: 1. Compliance and Certification Management System (CCMS)--via the Web portal: http...
10 CFR 435.305 - Alternative compliance procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Alternative compliance procedure. 435.305 Section 435.305... Alternative compliance procedure. (a) If a proposed building design includes unusual or innovative energy... estimated unit energy cost on the compliance forms, on the basis of selecting the optimum levels on the...
10 CFR 435.305 - Alternative compliance procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Alternative compliance procedure. 435.305 Section 435.305... Alternative compliance procedure. (a) If a proposed building design includes unusual or innovative energy... estimated unit energy cost on the compliance forms, on the basis of selecting the optimum levels on the...
10 CFR 435.305 - Alternative compliance procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Alternative compliance procedure. 435.305 Section 435.305... Alternative compliance procedure. (a) If a proposed building design includes unusual or innovative energy... estimated unit energy cost on the compliance forms, on the basis of selecting the optimum levels on the...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Compliance. 851.13 Section 851.13 Energy DEPARTMENT OF ENERGY WORKER SAFETY AND HEALTH PROGRAM Program Requirements § 851.13 Compliance. (a) Contractors must achieve compliance with all the requirements of Subpart C of this part, and their approved worker safety...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Compliance. 2.1012 Section 2.1012 Energy NUCLEAR... Geologic Repository § 2.1012 Compliance. (a) If the Department of Energy fails to make its initial... storage media in a format consistent with NRC regulations and guidance, or for non-compliance with any...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Compliance. 851.13 Section 851.13 Energy DEPARTMENT OF ENERGY WORKER SAFETY AND HEALTH PROGRAM Program Requirements § 851.13 Compliance. (a) Contractors must achieve compliance with all the requirements of Subpart C of this part, and their approved worker safety...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, C.; Faillace, E.; Chen, S.Y.
RESRAD was one of the multimedia models selected by the US Nuclear Regulatory Commission (NRC) to include in its workshop on radiation dose modeling and demonstration of compliance with the radiological criteria for license termination. This paper is a summary of the presentation made at the workshop and focuses on the 10 questions the NRC distributed to all participants prior to the workshop. The code selection criteria, which were solicited by the NRC, for demonstrating compliance with the license termination rule are also included. Among the RESRAD family of codes, RESRAD and RESRAD-BUILD are designed for evaluating radiological contamination inmore » soils and in buildings. Many documents have been published to support the use of these codes. This paper focuses on these two codes. The pathways considered, the databases and parameters used, quality control and quality assurance, benchmarking, verification and validation of these codes, and capabilities as well as limitations of these codes are discussed in detail.« less
Scanning for safety: an integrated approach to improved bar-code medication administration.
Early, Cynde; Riha, Chris; Martin, Jennifer; Lowdon, Karen W; Harvey, Ellen M
2011-03-01
This is a review of lessons learned in the postimplementation evaluation of a bar-code medication administration technology implemented at a major tertiary-care hospital in 2001. In 2006, with a bar-code medication administration scan compliance rate of 82%, a near-miss sentinel event prompted review of this technology as part of an institutional recommitment to a "culture of safety." Multifaceted problems with bar-code medication administration created an environment of circumventing safeguards as demonstrated by an increase in manual overrides to ensure timely medication administration. A multiprofessional team composed of nursing, pharmacy, human resources, quality, and technical services formalized. Each step in the bar-code medication administration process was reviewed. Technology, process, and educational solutions were identified and implemented systematically. Overall compliance with bar-code medication administration rose from 82% to 97%, which resulted in a calculated cost avoidance of more than $2.8 million during this time frame of the project.
Space Telecommunications Radio System (STRS) Compliance Testing
NASA Technical Reports Server (NTRS)
Handler, Louis M.
2011-01-01
The Space Telecommunications Radio System (STRS) defines an open architecture for software defined radios. This document describes the testing methodology to aid in determining the degree of compliance to the STRS architecture. Non-compliances are reported to the software and hardware developers as well as the NASA project manager so that any non-compliances may be fixed or waivers issued. Since the software developers may be divided into those that provide the operating environment including the operating system and STRS infrastructure (OE) and those that supply the waveform applications, the tests are divided accordingly. The static tests are also divided by the availability of an automated tool that determines whether the source code and configuration files contain the appropriate items. Thus, there are six separate step-by-step test procedures described as well as the corresponding requirements that they test. The six types of STRS compliance tests are: STRS application automated testing, STRS infrastructure automated testing, STRS infrastructure testing by compiling WFCCN with the infrastructure, STRS configuration file testing, STRS application manual code testing, and STRS infrastructure manual code testing. Examples of the input and output of the scripts are shown in the appendices as well as more specific information about what to configure and test in WFCCN for non-compliance. In addition, each STRS requirement is listed and the type of testing briefly described. Attached is also a set of guidelines on what to look for in addition to the requirements to aid in the document review process.
Measuring compliance with the Baby-Friendly Hospital Initiative.
Haiek, Laura N
2012-05-01
The WHO/UNICEF Baby-Friendly Hospital Initiative (BFHI) is an effective strategy to increase breast-feeding exclusivity and duration but many countries have been slow to implement it. The present paper describes the development of a computer-based instrument that measures policies and practices outlined in the BFHI. The tool uses clinical staff/managers' and pregnant women/mothers' opinions as well as maternity unit observations to assess compliance with the BFHI's Ten Steps to Successful Breastfeeding (Ten Steps) and the International Code of Marketing of Breastmilk Substitutes (Code) by measuring the extent of implementation of two to fourteen indicators for each step and the Code. Composite scores are used to summarize results. Examples of results from a 2007 assessment performed in nine hospitals in the province of Québec are presented to illustrate the type of information returned to individual hospitals and health authorities. Participants included nine to fifteen staff/managers per hospital randomly selected among those present during the interviewer-observer's 12 h hospital visit and nine to forty-five breast-feeding mothers per hospital telephoned at home after being randomly selected from birth certificates. The Ten Steps Global Compliance Score for the nine hospitals varied between 2.87 and 6.51 (range 0-10, mean 5.06) whereas the Code Global Compliance Score varied between 0.58 and 1 (range 0-1, mean 0.83). Instrument development, examples of assessment results and potential applications are discussed. A methodology to measure BFHI compliance may help support the implementation of this effective intervention and contribute to improved maternal and child health.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vine, E.
Based on an evaluation of 10 residential new construction programs, primarily sponsored by investor-owned utilities in the United States, we find that many of these programs are in dire straits and are in danger of being discontinued because current inclusion of only direct program effects leads to the conclusion that they are not cost-effective. We believe that the cost-effectiveness of residential new construction programs can be improved by: (1) promoting technologies and advanced building design practices that significantly exceed state and federal standards; (2) reducing program marketing costs and developing more effective marketing strategies; (3) recognizing the role of thesemore » programs in increasing compliance with existing state building codes; and (4) allowing utilities to obtain an ``energy-savings credit`` from utility regulators for program spillover (market transformation) impacts. Utilities can also leverage their resources in seizing these opportunities by forming strong and trusting partnerships with the building community and with local and state government.« less
Radiological NESHAP ANNUAL REPORT CY 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evelo, Stacie
2017-06-01
This report provides a summary of the radionuclide releases from the United States (U.S.) Department of Energy (DOE) National Nuclear Security Administration facilities at Sandia National Laboratories, New Mexico (SNL/NM) during Calendar Year (CY) 2016, including the data, calculations, and supporting documentation for demonstrating compliance with 40 Code of Federal Regulation (CFR) 61, Subpart H--NATIONAL EMISSION STANDARDS FOR EMISSIONS OF RADIONUCLIDES OTHER THAN RADON FROM DEPARTMENT OF ENERGY FACILITIES (Radiological NESHAP). A description is given of the sources and their contributions to the overall dose assessment. In addition, the maximally exposed individual (MEI) radiological dose calculation and the population dosemore » to local and regional residents are discussed.« less
76 FR 23490 - Aluminum tris (O
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-27
... code 112). Food manufacturing (NAICS code 311). Pesticide manufacturing (NAICS code 32532). This... used to avoid contamination of food, feed, or food-contact/feed-contact surfaces. Compliance with the... are an agricultural producer, food manufacturer, or pesticide manufacturer. Potentially affected...
DOE Office of Scientific and Technical Information (OSTI.GOV)
evelo, stacie; Miller, Mark L.
2015-05-01
This report provides a summary of the radionuclide releases from the United States (U.S.) Department of Energy (DOE) National Nuclear Security Administration facilities at Sandia National Laboratories, New Mexico (SNL/NM) during Calendar Year (CY) 2014, including the data, calculations, and supporting documentation for demonstrating compliance with 40 Code of Federal Regulation (CFR) 61, Subpart H--NATIONAL EMISSION STANDARDS FOR EMISSIONS OF RADIONUCLIDES OTHER THAN RADON FROM DEPARTMENT OF ENERGY FACILITIES. A description is given of the sources and their contributions to the overall dose assessment. In addition, the maximally exposed individual (MEI) radiological dose calculation and the population dose to localmore » and regional residents are discussed.« less
10 CFR 851.4 - Compliance order.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Compliance order. 851.4 Section 851.4 Energy DEPARTMENT OF ENERGY WORKER SAFETY AND HEALTH PROGRAM General Provisions § 851.4 Compliance order. (a) The Secretary... effectiveness of a Compliance Order unless the Secretary issues an order to that effect. (d) A copy of the...
40 CFR 51.362 - Motorist compliance enforcement program oversight.
Code of Federal Regulations, 2010 CFR
2010-07-01
... collection through the use of automatic data capture systems such as bar-code scanners or optical character... determination of compliance through parking lot surveys, road-side pull-overs, or other in-use vehicle...
40 CFR 51.362 - Motorist compliance enforcement program oversight.
Code of Federal Regulations, 2011 CFR
2011-07-01
... collection through the use of automatic data capture systems such as bar-code scanners or optical character... determination of compliance through parking lot surveys, road-side pull-overs, or other in-use vehicle...
75 FR 4579 - Certificate of Alternative Compliance for the Tugboat MR SAM
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
... Compliance for the Tugboat MR SAM AGENCY: Coast Guard, DHS. ACTION: Notice. SUMMARY: The Coast Guard announces that a Certificate of Alternative Compliance was issued for the tugboat MR SAM as required by 33 U... Title 33, Code of Federal Regulations, Parts 81 and 89, has been issued for the tugboat MR SAM, O.N...
ERIC Educational Resources Information Center
Bryce, Crystal I.; Jahromi, Laudan B.
2013-01-01
The present study examined children's compliance and noncompliance behaviors in response to parental control strategies in 20 children with high-functioning autism (HFA) and 20 matched typically-developing children. Observational coding was used to measure child compliance (committed, situational), noncompliance (passive, defiance, self-assertion,…
Bar code-based pre-transfusion check in pre-operative autologous blood donation.
Ohsaka, Akimichi; Furuta, Yoshiaki; Ohsawa, Toshiya; Kobayashi, Mitsue; Abe, Katsumi; Inada, Eiichi
2010-10-01
The objective of this study was to demonstrate the feasibility of a bar code-based identification system for the pre-transfusion check at the bedside in the setting of pre-operative autologous blood donation (PABD). Between July 2003 and December 2008 we determined the compliance rate and causes of failure of electronic bedside checking for PABD transfusion. A total of 5627 (9% of all transfusions) PABD units were administered without a single mistransfusion. The overall rate of compliance with electronic checking was 99%. The bar code-based identification system was applicable to the pre-transfusion check for PABD transfusion. Copyright © 2010 Elsevier Ltd. All rights reserved.
10 CFR 490.805 - Application for waiver.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Application for waiver. 490.805 Section 490.805 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... alternative compliance and whether the fleet is in compliance with Clean Air Act vehicle emission standards...
10 CFR 490.805 - Application for waiver.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Application for waiver. 490.805 Section 490.805 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... alternative compliance and whether the fleet is in compliance with Clean Air Act vehicle emission standards...
10 CFR 490.805 - Application for waiver.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Application for waiver. 490.805 Section 490.805 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... alternative compliance and whether the fleet is in compliance with Clean Air Act vehicle emission standards...
10 CFR 490.805 - Application for waiver.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Application for waiver. 490.805 Section 490.805 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... alternative compliance and whether the fleet is in compliance with Clean Air Act vehicle emission standards...
10 CFR 490.805 - Application for waiver.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Application for waiver. 490.805 Section 490.805 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... alternative compliance and whether the fleet is in compliance with Clean Air Act vehicle emission standards...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hathcock, Charles Dean
This floodplain assessment was prepared in accordance with 10 Code of Federal Regulations (CFR) 1022 Compliance with Floodplain and Wetland Environmental Review Requirements, which was promulgated to implement the U.S. Department of Energy (DOE) requirements under Executive Order 11988 Floodplain Management and Executive Order 11990 Wetlands Protection. According to 10 CFR 1022, a 100-year floodplain is defined as “the lowlands adjoining inland and coastal waters and relatively flat areas and flood prone areas of offshore islands.” In this action, DOE is proposing to collect soil investigation samples and remove contaminated soil within and around selected solid waste management units (SWMUs)more » near and within the 100-year floodplain (hereafter “floodplain”) in north Ancho Canyon at Los Alamos National Laboratory (LANL). The work is being performed to comply with corrective action requirements under the 2016 Compliance Order on Consent.« less
Stickler, Claudia M; Nepstad, Daniel C; Azevedo, Andrea A; McGrath, David G
2013-06-05
Land-use regulations are a critical component of forest governance and conservation strategies, but their effectiveness in shaping landholder behaviour is poorly understood. We conducted a spatial and temporal analysis of the Brazilian Forest Code (BFC) to understand the patterns of regulatory compliance over time and across changes in the policy, and the implications of these compliance patterns for the perceived costs to landholders and environmental performance of agricultural landscapes in the southern Amazon state of Mato Grosso. Landholdings tended to remain in compliance or not according to their status at the beginning of the study period. The perceived economic burden of BFC compliance on soya bean and beef producers (US$3-5.6 billion in net present value of the land) may in part explain the massive, successful campaign launched by the farm lobby to change the BFC. The ecological benefits of compliance (e.g. greater connectivity and carbon) with the BFC are diffuse and do not compete effectively with the economic benefits of non-compliance that are perceived by landholders. Volatile regulation of land-use decisions that affect billions in economic rent that could be captured is an inadequate forest governance instrument; effectiveness of such regulations may increase when implemented in tandem with positive incentives for forest conservation.
38 CFR 61.15 - Obtaining additional information and awarding capital grants.
Code of Federal Regulations, 2011 CFR
2011-07-01
... establishing compliance with local and state zoning codes; (7) Documentation in the form of one set of design... ensure compliance with the provisions of the National Environmental Policy Act (42 U.S.C. 4321 et seq...
38 CFR 61.15 - Obtaining additional information and awarding capital grants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... establishing compliance with local and state zoning codes; (7) Documentation in the form of one set of design... ensure compliance with the provisions of the National Environmental Policy Act (42 U.S.C. 4321 et seq...
learn about the NSPS for municipal solid waste landfills by reading the rule summary, rule history, code of federal regulations text, fact sheets, background information documents, related rules and compliance information.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, Amir; Goldwasser, David; Parker, Andrew
The OpenStudio software development kit has played a significant role in the adoption of the EnergyPlus whole building energy modeling engine and in the development and launch of new applications that use EnergyPlus for a variety of purposes, from design to auditing to code compliance and management of large portfolios. One of the most powerful features of the OpenStudio platform is Measure, a scripting facility similar to Excel's Visual Basic macros. Measures can be used to apply energy conservation measures to models--hence the name--to create reports and visualizations, and even to sew together custom workflows. Measures automate tedious tasks increasingmore » modeler productivity and reducing error. Measures have also become a currency in the OpenStudio tools ecosystem, a way to codify knowledge and protocol and transfer it from one modeler to another, either within an organization or within the global modeling community. This paper describes some of the many applications of Measures.« less
10 CFR 1040.102 - Compliance information.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Compliance information. 1040.102 Section 1040.102 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION IN FEDERALLY ASSISTED PROGRAMS OR ACTIVITIES Program Monitoring § 1040.102 Compliance information. (a) Cooperation and assistance. Each responsible...
10 CFR 1040.102 - Compliance information.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Compliance information. 1040.102 Section 1040.102 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION IN FEDERALLY ASSISTED PROGRAMS OR ACTIVITIES Program Monitoring § 1040.102 Compliance information. (a) Cooperation and assistance. Each responsible...
10 CFR 1040.102 - Compliance information.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Compliance information. 1040.102 Section 1040.102 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION IN FEDERALLY ASSISTED PROGRAMS OR ACTIVITIES Program Monitoring § 1040.102 Compliance information. (a) Cooperation and assistance. Each responsible...
10 CFR 1040.102 - Compliance information.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Compliance information. 1040.102 Section 1040.102 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION IN FEDERALLY ASSISTED PROGRAMS OR ACTIVITIES Program Monitoring § 1040.102 Compliance information. (a) Cooperation and assistance. Each responsible...
How families cope with diabetes in adolescence. An approach and case analyses.
Hauser, S T; Paul, E L; Jacobson, A M; Weiss-Perry, B; Vieyra, M A; Rufo, P; Spetter, L D; DiPlacido, J; Wertlieb, D; Wolfsdorf, J
1988-01-01
In this paper we describe our newly constructed Family Coping Coding System. This scheme was constructed to identify family coping strategies that involve appraisal, problem solving, and emotion management dimensions. We discuss the theoretical rationale, meanings and reliability of the coping codes, and illustrate them through excerpts drawn from family discussions of a recent stressful situation (the onset of a chronic or acute illness in an adolescent member). Finally, we consider the clinical research relevance of this new assessment technique, exemplifying this potential with respect to medical compliance. We present analyses of two families with diabetic adolescents who strikingly differ with respect to compliance, and explore which family coping strategies may be predictive of an adolescent's favorable or problematic compliance to diabetes management.
Certifying Domain-Specific Policies
NASA Technical Reports Server (NTRS)
Lowry, Michael; Pressburger, Thomas; Rosu, Grigore; Koga, Dennis (Technical Monitor)
2001-01-01
Proof-checking code for compliance to safety policies potentially enables a product-oriented approach to certain aspects of software certification. To date, previous research has focused on generic, low-level programming-language properties such as memory type safety. In this paper we consider proof-checking higher-level domain -specific properties for compliance to safety policies. The paper first describes a framework related to abstract interpretation in which compliance to a class of certification policies can be efficiently calculated Membership equational logic is shown to provide a rich logic for carrying out such calculations, including partiality, for certification. The architecture for a domain-specific certifier is described, followed by an implemented case study. The case study considers consistency of abstract variable attributes in code that performs geometric calculations in Aerospace systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PRACTICES AND PERSONAL CONFLICTS OF INTEREST Contractor Code of Business Ethics and Conduct 3.1002 Policy.... (b) Contractors should have a written code of business ethics and conduct. To promote compliance with such code of business ethics and conduct, contractors should have an employee business ethics and...
76 FR 34937 - Amitraz, Bentazon, Bifenthrin, Chlorfenapyr, Cyfluthrin, Deltamethrin, et al
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-15
... production (NAICS code 112). Food manufacturing (NAICS code 311). Pesticide manufacturing (NAICS code 32532... food/feed handling establishments (including food service, manufacturing and processing establishments... ingredient; and contamination of food/ feed or food/feed contact surfaces shall be avoided. Compliance with...
Rosenthal, Marjorie S; Jeon, Sangchoon; Crowley, Angela A
2016-05-01
To determine frequency of non-compliance with child care regulations among family day care homes (FDCH) and identify the role of income in compliance. We analyzed non-compliance in 746 routine, unannounced inspection and re-inspection reports of FDCH collected by the Connecticut Department of Public Health licensing specialists in 2007-2008 and linked results to median income of zip code data. We grouped the 83 state regulations into 12 regulation categories, analyzed 11 categories, and used latent class analysis to classify each FDCH as high or low compliance for each category. We used logistic regression analysis to estimate the odds ratios of low compliance. Among the 746 FDCH inspections (594 first inspections and 152 re-inspections), we found high rates of non-compliance in inspection regulations in immunizations (32.9 %), water temperature (35.6 %) and hazards (30.0 %). Among the 11 regulation categories, 4 categories (indoor safety, emergency preparedness, child/family/staff documentation, and qualifications of provider) had regulations with high non-compliance. Median household income of FDCH zip code was lower for re-inspection sites than for inspection sites ($34,715 vs. $57,118, p < 0.0001) and FDCH in the lowest quartile of income had greater odds of low compliance in indoor safety (OR 1.86, 95 % CI 1.04, 3.35, p < 0.05). The majority of FDCH were in compliance with the majority of regulations, yet there are glaring non-compliance issues in inspections and re-inspections and there are income-based inequities that place children at higher risk who are already at high risk for suboptimal health outcomes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.; Barnett, J. Matthew; Bisping, Lynn E.
This report documents radionuclide air emissions that result in the 2014 highest effective dose equivalent (EDE) to an offsite member of the public, referred to as the maximally exposed individual (MEI). The report has been prepared in compliance with the Code of Federal Regulations (CFR), Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (NESHAP), Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code (WAC) Chapter 246-247, “Radiation Protection–Air Emissions.” The dose to the PNNL Campus MEI due to routine major andmore » minor point source emissions in 2014 from PNNL Campus sources is 2E 05 mrem (2E-07 mSv) EDE. The dose from all fugitive sources is 3E-6 mrem (3E-8 mSv) EDE. The dose from radon emissions is 1E-6 mrem (1E-8 mSv) EDE. No nonroutine emissions occurred in 2014. The total radiological dose for 2014 to the MEI from all PNNL Campus radionuclide emissions, including fugitive emissions and radon, is 3E-5 mrem (3E-7 mSv) EDE, or more than 100,000 times smaller than the federal and state standard of 10 mrem/yr, to which the PNNL Campus is in compliance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.; Barnett, J. Matthew; Bisping, Lynn E.
This report documents radionuclide air emissions that result in the highest effective dose equivalent (EDE) to a member of the public, referred to as the maximally exposed individual (MEI). The report has been prepared in compliance with the Code of Federal Regulations (CFR), Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (NESHAP), Subpart H, National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities and Washington Administrative Code (WAC) Chapter 246-247, Radiation Protection Air Emissions. The dose to the PNNL Site MEI due to routine major and minormore » point source emissions in 2013 from PNNL Site sources is 2E-05 mrem (2E-07 mSv) EDE. The dose from fugitive emissions (i.e., unmonitored sources) is 2E-6 mrem (2E-8 mSv) EDE. The dose from radon emissions is 1E-11 mrem (1E-13 mSv) EDE. No nonroutine emissions occurred in 2013. The total radiological dose for 2013 to the MEI from all PNNL Site radionuclide emissions, including fugitive emissions and radon, is 2E-5 mrem (2E-7 mSv) EDE, or 100,000 times smaller than the federal and state standard of 10 mrem/yr, to which the PNNL Site is in compliance« less
76 FR 5215 - Draft Regulatory Guide: Issuance, Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-28
... Compliance with Packaging Requirements for Shipment and Receipt of Radioactive Material,'' is temporarily... Code of Federal Regulations, Part 71, ``Packaging and Transportation of Radioactive Material'' (10 CFR... Compliance with Packaging Requirements for Shipments of Radioactive Materials,'' as an acceptable process for...
2014-08-06
This final rule updates the prospective payment rates for inpatient rehabilitation facilities (IRFs) for federal fiscal year (FY) 2015 as required by the statute. This final rule finalizes a policy to collect data on the amount and mode (that is, Individual, Concurrent, Group, and Co-Treatment) of therapy provided in the IRF setting according to therapy discipline, revises the list of diagnosis and impairment group codes that presumptively meet the "60 percent rule'' compliance criteria, provides a way for IRFs to indicate on the Inpatient Rehabilitation Facility-Patient Assessment Instrument (IRF-PAI) form whether the prior treatment and severity requirements have been met for arthritis cases to presumptively meet the "60 percent rule'' compliance criteria, and revises and updates quality measures and reporting requirements under the IRF quality reporting program (QRP). This rule also delays the effective date for the revisions to the list of diagnosis codes that are used to determine presumptive compliance under the "60 percent rule'' that were finalized in FY 2014 IRF PPS final rule and adopts the revisions to the list of diagnosis codes that are used to determine presumptive compliance under the "60 percent rule'' that are finalized in this rule. This final rule also addresses the implementation of the International Classification of Diseases, 10th Revision, Clinical Modification (ICD-10-CM), for the IRF prospective payment system (PPS), which will be effective when ICD-10-CM becomes the required medical data code set for use on Medicare claims and IRF-PAI submissions.
Computer-assisted coding and clinical documentation: first things first.
Tully, Melinda; Carmichael, Angela
2012-10-01
Computer-assisted coding tools have the potential to drive improvements in seven areas: Transparency of coding. Productivity (generally by 20 to 25 percent for inpatient claims). Accuracy (by improving specificity of documentation). Cost containment (by reducing overtime expenses, audit fees, and denials). Compliance. Efficiency. Consistency.
A systematic review of compliance to oral nutritional supplements.
Hubbard, Gary P; Elia, Marinos; Holdoway, Anne; Stratton, Rebecca J
2012-06-01
Oral nutritional supplements (ONS) play a key role in the management of malnutrition. This systematic review examined patients' compliance with ONS across healthcare settings and the influence of patient and ONS-related factors. A systematic review identified 46 studies (n = 4328) of ONS in which data on compliance (% of prescribed quantity of ONS consumed) was available. Pooled mean %compliance was assessed overall and according to study design and healthcare setting. Inter-relationships between compliance and ONS-related and patient-related factors, and total energy intake were assessed. Overall mean compliance with ONS was 78% (37%-100%; 67% hospital, 81% community; overall mean ONS intake 433 kcal/d). Percentage compliance was similar in randomised (79%) and non-randomised (77%) trials, with little variation between diagnostic groups. Compliance across a heterogeneous group of unmatched studies was positively associated with higher energy-density ONS and greater ONS and total energy intakes, negatively associated with age, and unrelated to amount or duration of ONS prescription. This systematic review suggests that compliance to ONS is good, especially with higher energy-density ONS, resulting in improvements in patients' total energy intakes that have been linked with clinical benefits. Further research is required to address the compliance and effectiveness of other common methods of oral nutritional support. Copyright © 2011 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Dodgson, Joan E; Watkins, Amanda L; Bond, Angela B; Kintaro-Tagaloa, Cheryl; Arellano, Alondra; Allred, Patrick A
2014-04-01
Abstract The importance of breastmilk as a primary preventative intervention is widely known and understood by most healthcare providers. The actions or non-actions that heathcare providers take toward promoting and supporting breastfeeding families make a difference in the success and duration of breastfeeding. Recognizing this relationship, the World Health Organization developed the International Code of Marketing of Breast-milk Substitutes (the Code), which defines best practices in breastfeeding promotion, including physicians' offices. The pediatric practices' waiting rooms are often a family's first experience with pediatric care. The specific aims of this study were to describe (1) Code compliance, (2) the demographic factors affecting the Code compliance, and (3) the amount and type of breastfeeding-supportive materials available in the pediatricians' waiting rooms. An observational cross-sectional design was used to collect data from 163 (82%) of the pediatric practices in Maricopa County, Arizona. None of the 100 waiting rooms that had any materials displayed (61%) was found to be completely Code compliant, with 81 of the offices having formula-promotional materials readily available. Waiting rooms in higher income areas offered more non-Code-compliant materials and gifts. Breastfeeding support information and materials were lacking in all but 18 (18%) offices. A positive relationship (t97=-2.31, p=0.02) occurred between the presence of breastfeeding educational materials and higher income areas. We were able to uncover some practice-related patterns that impact families and potentially undermine breastfeeding success. To move current practices toward breastfeeding-friendly physicians' offices, change is needed.
10 CFR 590.406 - Compliance with orders.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Compliance with orders. 590.406 Section 590.406 Energy DEPARTMENT OF ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS Opinions and Orders § 590.406 Compliance with...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-21
..., regarding the Energy Conservation Program: Certification, Compliance, and Enforcement for Consumer Products... [Docket No. EERE-2010-BT-CE-0014] RIN 1904-AC23 Energy Conservation Program: Certification, Compliance, and Enforcement for Consumer Products and Commercial and Industrial Equipment; Correction AGENCY...
Do cigarette health warning labels comply with requirements: A 14-country study.
Cohen, Joanna E; Brown, Jennifer; Washington, Carmen; Welding, Kevin; Ferguson, Jacqueline; Smith, Katherine C
2016-12-01
The Framework Convention on Tobacco Control, a global health treaty ratified by over 175 countries, calls on countries to ensure that tobacco packages carry health warning labels (HWLs) describing the harmful effects of tobacco use. We assessed the extent of compliance with 14 countries' HWL requirements. Unique cigarette packs were purchased in 2013 using a systematic protocol in 12 distinct neighborhoods within three of the ten most populous cities in the 14 low- and middle-income countries with the greatest number (count) of smokers. HWL compliance codebooks were developed for each country based on the details of country-specific HWL requirements, with up to four common compliance indicators assessed for each country (location, size, label elements, text size). Packs (n=1859) were double coded for compliance. Compliance was examined by country and pack characteristics, including parent company and brand family. Overall, 72% of coded cigarette packs were compliant with all relevant compliance indicators, ranging from 17% in the Philippines to 94% in Mexico. Compliance was highest for location of the warning (ranging from 75%-100%) and lowest for warning size (ranging from 46%-99%). Compliance was higher for packs bought in high SES neighborhoods, and varied by parent company and brand family. This multi-country study found at least one pack in every country - and many packs in some countries - that were not compliant with key requirements for health warning labels in the country of purchase. Non-compliance may be exacerbating health disparities. Tobacco companies should be held accountable for complying with country HWL requirements. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Stickler, Claudia M.; Nepstad, Daniel C.; Azevedo, Andrea A.; McGrath, David G.
2013-01-01
Land-use regulations are a critical component of forest governance and conservation strategies, but their effectiveness in shaping landholder behaviour is poorly understood. We conducted a spatial and temporal analysis of the Brazilian Forest Code (BFC) to understand the patterns of regulatory compliance over time and across changes in the policy, and the implications of these compliance patterns for the perceived costs to landholders and environmental performance of agricultural landscapes in the southern Amazon state of Mato Grosso. Landholdings tended to remain in compliance or not according to their status at the beginning of the study period. The perceived economic burden of BFC compliance on soya bean and beef producers (US$3–5.6 billion in net present value of the land) may in part explain the massive, successful campaign launched by the farm lobby to change the BFC. The ecological benefits of compliance (e.g. greater connectivity and carbon) with the BFC are diffuse and do not compete effectively with the economic benefits of non-compliance that are perceived by landholders. Volatile regulation of land-use decisions that affect billions in economic rent that could be captured is an inadequate forest governance instrument; effectiveness of such regulations may increase when implemented in tandem with positive incentives for forest conservation. PMID:23610168
40 CFR 194.23 - Models and computer codes.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...
40 CFR 194.23 - Models and computer codes.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...
40 CFR 194.23 - Models and computer codes.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...
40 CFR 194.23 - Models and computer codes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...
40 CFR 194.23 - Models and computer codes.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...
78 FR 62488 - Energy Conservation Program: Compliance Date for the Dehumidifier Test Procedure
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... Conservation Program: Compliance Date for the Dehumidifier Test Procedure AGENCY: Office of Energy Efficiency.... Department of Energy (DOE) proposes to revise the compliance date for the dehumidifier test procedures... manufacturers to test using only the active mode provisions in the test procedure for dehumidifiers currently...
A Study to Determine the Correlation between Continuity of Care and Patient Medication Compliance
1984-08-01
U (III FILE ’Y TO DETERMINE THE CORRELATION BETWEEN CONTINUITY OF CARE AND PATIENT MEDICATION COMPLIANCE IA Graduate Research Project Submitted to...43 APPENDIX A. PATIENT MEDICATION COMPLIANCE QUESTIONNAIRE . . . . . 45 B. COMPUTER CODED INPUT FORMAT . . . . . . . ...... 48 C. RESEARCH DATA...and that adhered to by the patient . This failure to comply with medical recommendations results in a waste of health resources, frustration to the
78 FR 52607 - Unified Registration System
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-23
...'' and click ``Search.'' Next, click ``Open Docket Folder'' in the ``Actions'' column. Finally, in the... comments received are posted without change to http://www.regulations.gov . Anyone is able to search the... License CFR Code of Federal Regulations CMV Commercial Motor Vehicle CR Compliance Review CSA Compliance...
Three decades of the WHO code and marketing of infant formulas.
Forsyth, Stewart
2012-05-01
The International Code of Marketing of Breast Milk Substitutes states that governments, non-governmental organizations, experts, consumers and industry need to cooperate in activities aimed at improving infant nutrition. However, the evidence from the last three decades is that of a series of disputes, legal proceedings and boycotts. The purpose of this review is to assess the overall progress in the implementation of the Code and to examine the problematic areas of monitoring, compliance and governance. There are continuing issues of implementation, monitoring and compliance which predominantly reflect weak governance. Many Member States have yet to fully implement the Code recommendations and most States do not have adequate monitoring and reporting mechanisms. Application of the Code in developed countries may be undermined by a lack of consensus on the WHO recommendation of 6 months exclusive breastfeeding. There is evidence of continuing conflict and acrimony, especially between non-government organizations and industry. Measures need to be taken to encourage the Member States to implement the Code and to establish the governance systems that will not only ensure effective implementation and monitoring of the Code, but also deliver the Code within a spirit of participation, collaboration and trust.
Predicting Regulatory Compliance in Beer Advertising on Facebook.
Noel, Jonathan K; Babor, Thomas F
2017-11-01
The prevalence of alcohol advertising has been growing on social media platforms. The purpose of this study was to evaluate alcohol advertising on Facebook for regulatory compliance and thematic content. A total of 50 Budweiser and Bud Light ads posted on Facebook within 1 month of the 2015 NFL Super Bowl were evaluated for compliance with a self-regulated alcohol advertising code and for thematic content. An exploratory sensitivity/specificity analysis was conducted to determine if thematic content could predict code violations. The code violation rate was 82%, with violations prevalent in guidelines prohibiting the association of alcohol with success (Guideline 5) and health benefits (Guideline 3). Overall, 21 thematic content areas were identified. Displaying the product (62%) and adventure/sensation seeking (52%) were the most prevalent. There was perfect specificity (100%) for 10 content areas for detecting any code violation (animals, negative emotions, positive emotions, games/contests/promotions, female characters, minorities, party, sexuality, night-time, sunrise) and high specificity (>80%) for 10 content areas for detecting violations of guidelines intended to protect minors (animals, negative emotions, famous people, friendship, games/contests/promotions, minorities, responsibility messages, sexuality, sunrise, video games). The high prevalence of code violations indicates a failure of self-regulation to prevent potentially harmful content from appearing in alcohol advertising, including explicit code violations (e.g. sexuality). Routine violations indicate an unwillingness to restrict advertising content for public health purposes, and statutory restrictions may be necessary to sufficiently deter alcohol producers from repeatedly violating marketing codes. Violations of a self-regulated alcohol advertising code are prevalent in a sample of beer ads published on Facebook near the US National Football League's Super Bowl. Overall, 16 thematic content areas demonstrated high specificity for code violations. Alcohol advertising codes should be updated to expressly prohibit the use of such content. © The Author 2017. Medical Council on Alcohol and Oxford University Press. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper willmore » describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.« less
26 CFR 1.42-5 - Monitoring compliance with low-income housing credit requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... be required to retain the original local health, safety, or building code violation reports or... account local health, safety, and building codes (or other habitability standards), and the State or local government unit responsible for making local health, safety, or building code inspections did not issue a...
26 CFR 1.42-5 - Monitoring compliance with low-income housing credit requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... be required to retain the original local health, safety, or building code violation reports or... account local health, safety, and building codes (or other habitability standards), and the State or local government unit responsible for making local health, safety, or building code inspections did not issue a...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-28
...: Crop production (NAICS code 111). Animal production (NAICS code 112). Food manufacturing (NAICS code... contamination of food, feed, or food-contact/feed-contact surfaces. Compliance with the tolerance level... Apply to Me? You may be potentially affected by this action if you are an agricultural producer, food...
Using Third-Party Inspectors in Building Energy Codes Enforcement in India
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Sha; Evans, Meredydd; Kumar, Pradeep
India is experiencing fast income growth and urbanization, and this leads to unprecedented increases in demand for building energy services and resulting energy consumption. In response to rapid growth in building energy use, the Government of India issued the Energy Conservation Building Code (ECBC) in 2007, which is consistent with and based on the 2001 Energy Conservation Act. ECBC implementation has been voluntary since its enactment and a few states have started to make progress towards mandatory implementation. Rajasthan is the first state in India to adopt ECBC as a mandatory code. The State adopted ECBC with minor additions onmore » March 28, 2011 through a stakeholder process; it became mandatory in Rajasthan on September 28, 2011. Tamil Nadu, Gujarat, and Andhra Pradesh have started to draft an implementation roadmap and build capacity for its implementation. The Bureau of Energy Efficiency (BEE) plans to encourage more states to adopt ECBC in the near future, including Haryana, Uttar Pradesh, Karnataka, Maharashtra, West Bengal, and Delhi. Since its inception, India has applied the code on a voluntary basis, but the Government of India is developing a strategy to mandate compliance. Implementing ECBC requires coordination between the Ministry of Power and the Ministry of Urban Development at the national level as well as interdepartmental coordination at the state level. One challenge is that the Urban Local Bodies (ULBs), the enforcement entities of building by-laws, lack capacity to implement ECBC effectively. For example, ULBs in some states might find the building permitting procedures to be too complex; in other cases, lack of awareness and technical knowledge on ECBC slows down the amendment of local building by-laws as well as ECBC implementation. The intent of this white paper is to share with Indian decision-makers code enforcement approaches: through code officials, third-party inspectors, or a hybrid approach. Given the limited capacity and human resources available in the state and local governments, involving third-party inspectors could rapidly expand the capacity for plan reviews and broad implementation. However, the procedures of involving third-parties need to be carefully designed in order to guarantee a fair process. For example, there should be multiple checks and certification requirements for third-party inspectors, and the government should have the final approval when third-party inspectors are used in a project. This paper discusses different approaches of involving third-parties in ECBC enforcement; the Indian states may choose the approaches that work best in their given circumstances.« less
NASA Astrophysics Data System (ADS)
Zeitler, T.; Kirchner, T. B.; Hammond, G. E.; Park, H.
2014-12-01
The Waste Isolation Pilot Plant (WIPP) has been developed by the U.S. Department of Energy (DOE) for the geologic (deep underground) disposal of transuranic (TRU) waste. Containment of TRU waste at the WIPP is regulated by the U.S. Environmental Protection Agency (EPA). The DOE demonstrates compliance with the containment requirements by means of performance assessment (PA) calculations. WIPP PA calculations estimate the probability and consequence of potential radionuclide releases from the repository to the accessible environment for a regulatory period of 10,000 years after facility closure. The long-term performance of the repository is assessed using a suite of sophisticated computational codes. In a broad modernization effort, the DOE has overseen the transfer of these codes to modern hardware and software platforms. Additionally, there is a current effort to establish new performance assessment capabilities through the further development of the PFLOTRAN software, a state-of-the-art massively parallel subsurface flow and reactive transport code. Improvements to the current computational environment will result in greater detail in the final models due to the parallelization afforded by the modern code. Parallelization will allow for relatively faster calculations, as well as a move from a two-dimensional calculation grid to a three-dimensional grid. The result of the modernization effort will be a state-of-the-art subsurface flow and transport capability that will serve WIPP PA into the future. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. This research is funded by WIPP programs administered by the Office of Environmental Management (EM) of the U.S Department of Energy.
10 CFR 431.97 - Energy efficiency standards and their compliance dates.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Energy efficiency standards and their compliance dates. 431.97 Section 431.97 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Air Conditioners and Heat Pumps Energy Efficiency...
10 CFR 431.97 - Energy efficiency standards and their compliance dates.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Energy efficiency standards and their compliance dates. 431.97 Section 431.97 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Air Conditioners and Heat Pumps Energy Efficiency...
77 FR 17470 - Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-26
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [EL11-22-000, QF11-115-001, QF11-116-001, et al.] Notice of Compliance Filing Docket Nos. OREG 1, Inc EL11-22-000 OREG 2, Inc QF11-115-001 OREG...., OREG 3, Inc., and OREG 4, Inc filed compliance refund reports, pursuant to the Federal Energy...
77 FR 68884 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-16
... petition Docket Number FRA-2012-0060. A copy of the petition, as well as any written communications...] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 Code of Federal Regulations (CFR... equipment overhauls. PATH states that the material and inventory necessary to complete the required...
10 CFR 435.305 - Alternative compliance procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Alternative compliance procedure. 435.305 Section 435.305 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Residential Buildings § 435.305...
40 CFR Appendix III to Subpart S... - As-Received Inspection
Code of Federal Regulations, 2010 CFR
2010-07-01
...) General Compliance Provisions for Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light... Reading 7. Build Date 8. MIL light on/off status 9. Readiness code status 10. Stored OBD codes 11.Any...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Richard
As defined in the preamble of the final rule, the entire DOE facility on the Oak Ridge Reservation (ORR) must meet the 10 mrem/yr ED standard.1 In other words, the combined ED from all radiological air emission sources from Y-12 National Security Complex (Y-12 Complex), Oak Ridge National Laboratory (ORNL), East Tennessee Technology Park (ETTP), Oak Ridge Institute for Science and Education (ORISE) and any other DOE operation on the reservation must meet the 10 mrem/yr standard. Compliance with the standard is demonstrated through emission sampling, monitoring, calculations and radiation dose modeling in accordance with approved EPA methodologies and procedures.more » DOE estimates the ED to many individuals or receptor points in the vicinity of ORR, but it is the dose to the maximally exposed individual (MEI) that determines compliance with the standard.« less
User preference as quality markers of paediatric web sites.
Hernández-Borges, Angel A; Macías-Cervi, Pablo; Gaspar-Guardado, Asunción; Torres-Alvarez De Arcaya, María Luisa; Ruíz-Rabaza, Ana; Jiménez-Sosa, Alejandro
2003-09-01
Little is known about the ability of internet users to distinguish the best medical resources online, and how their preferences, measured by usage and popularity indexes, correlate with established quality criteria. Our objective was to analyse whether the number of inbound links and/or daily visits to a sample of paediatric web pages are reliable quality markers of the pages. Two-year follow-up study of 363 web pages with paediatric information. The number of inbound links and the average number of daily visits to the pages were calculated on a yearly basis. In addition, their rates of compliance with the codes of conduct, guidelines and/or principles of three international organizations were evaluated. The quality code most widely met by the sample web pages was the Health on the Net Foundation Code of Conduct (overall rate, 60.2%). Sample pages showed a low degree of compliance with principles related to privacy, confidentiality and electronic commerce (overall rate less than 45%). Most importantly, we observed a moderate, significant correlation between compliance with quality criteria and the number of inbound links (p < 0.001). However, no correlation was found between the number of daily visits to a page and its degree of compliance with the principles. Some indexes derived from the analysis of webmasters' hyperlinks could be reliable quality markers of medical web resources.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
... titled ``Certification, Compliance, and Enforcement Requirements for Certain Consumer Products and...-AA96 and 1904-AB53 Energy Conservation Program: Certification, Compliance, and Enforcement Requirements for Certain Consumer Products and Commercial and Industrial Equipment; Correction AGENCY: Office of...
75 FR 69432 - Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-12
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Compliance Filing November 5, 2010. Ameren Services Company, Northern Indiana Public Service Company Docket No. EL07-86-014. v.... submitted an errata reflecting changes to its October 29, 2010 compliance filing containing proposed...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-29
... of a code of ethics by an investment advisor to include, at a minimum: (i) Standards of business... any violations of the code of ethics promptly to the chief compliance officer (``CCO'') or, provided the CCO also receives reports of all violations, to other persons designated in the code of ethics...
Code Help: Can This Unique State Regulatory Intervention Improve Emergency Department Crowding?
Michael, Sean S; Broach, John P; Kotkowski, Kevin A; Brush, D Eric; Volturo, Gregory A; Reznek, Martin A
2018-05-01
Emergency department (ED) crowding adversely affects multiple facets of high-quality care. The Commonwealth of Massachusetts mandates specific, hospital action plans to reduce ED boarding via a mechanism termed "Code Help." Because implementation appears inconsistent even when hospital conditions should have triggered its activation, we hypothesized that compliance with the Code Help policy would be associated with reduction in ED boarding time and total ED length of stay (LOS) for admitted patients, compared to patients seen when the Code Help policy was not followed. This was a retrospective analysis of data collected from electronic, patient-care, timestamp events and from a prospective Code Help registry for consecutive adult patients admitted from the ED at a single academic center during a 15-month period. For each patient, we determined whether the concurrent hospital status complied with the Code Help policy or violated it at the time of admission decision. We then compared ED boarding time and overall ED LOS for patients cared for during periods of Code Help policy compliance and during periods of Code Help policy violation, both with reference to patients cared for during normal operations. Of 89,587 adult patients who presented to the ED during the study period, 24,017 (26.8%) were admitted to an acute care or critical care bed. Boarding time ranged from zero to 67 hours 30 minutes (median 4 hours 31 minutes). Total ED LOS for admitted patients ranged from 11 minutes to 85 hours 25 minutes (median nine hours). Patients admitted during periods of Code Help policy violation experienced significantly longer boarding times (median 20 minutes longer) and total ED LOS (median 46 minutes longer), compared to patients admitted under normal operations. However, patients admitted during Code Help policy compliance did not experience a significant increase in either metric, compared to normal operations. In this single-center experience, implementation of the Massachusetts Code Help regulation was associated with reduced ED boarding time and ED LOS when the policy was consistently followed, but there were adverse effects on both metrics during violations of the policy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.; Barnett, J. Matthew; Bisping, Lynn E.
This report documents radionuclide air emissions that result in the 2015 highest effective dose equivalent (EDE) to an offsite member of the public, referred to as the maximally exposed individual (MEI). The report has been prepared in compliance with the Code of Federal Regulations (CFR), Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (NESHAP), Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code (WAC) Chapter 246-247, “Radiation Protection–Air Emissions.” The dose to the PNNL Campus MEI from routine major and minormore » point source emissions in 2015 from PNNL Campus sources is 2.6E-4 mrem (2.6E-6 mSv) EDE. The dose from all fugitive sources is 1.8E-6 mrem (1.8E-8 mSv) EDE. The dose from radon emissions is 4.4E-8 mrem (4.4E-10 mSv) EDE. No nonroutine emissions occurred in 2015. The total radiological dose to the MEI from all PNNL Campus radionuclide emissions, including fugitive emissions and radon, is 2.6E-4 mrem (2.6E-6 mSv) EDE, or more than 10,000 times less than the federal and state standard of 10 mrem/yr, with which the PNNL Campus is in compliance.« less
Advanced Grid Simulator for Multi-Megawatt Power Converter Testing and Certification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koralewicz, Przemyslaw; Gevorgian, Vahan; Wallen, Robb
2017-02-16
Grid integration testing of inverter-coupled renewable energy technologies is an essential step in the qualification of renewable energy and energy storage systems to ensure the stability of the power system. New types of devices must be thoroughly tested and validated for compliance with relevant grid codes and interconnection requirements. For this purpose, highly specialized custom-made testing equipment is needed to emulate various types of realistic grid conditions that are required by certification bodies or for research purposes. For testing multi-megawatt converters, a high power grid simulator capable of creating controlled grid conditions and meeting both power quality and dynamic characteristicsmore » is needed. This paper describes the new grid simulator concept based on ABB's medium voltage ACS6000 drive technology that utilizes advanced modulation and control techniques to create an unique testing platform for various multi-megawatt power converter systems. Its performance is demonstrated utilizing the test results obtained during commissioning activities at the National Renewable Energy Laboratory in Colorado, USA.« less
10 CFR 1040.102 - Compliance information.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Compliance information. 1040.102 Section 1040.102 Energy... Program Monitoring § 1040.102 Compliance information. (a) Cooperation and assistance. Each responsible... times, in such form, and containing information as the responsible Department official or the designee...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-12
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD11-1-000] Reliability Monitoring, Enforcement and Compliance Issues; Notice of Technical Conference October 1, 2010. The Federal...-referenced proceeding to explore issues associated with reliability monitoring, enforcement and compliance...
78 FR 47824 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-06
... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration [Docket Number FRA-2013-0077] Petition for Waiver of Compliance In accordance with Part 211 of Title 49 Code of Federal Regulations (CFR), this document provides the public notice that by a document dated July 16, 2013, the Association of American Railroads (AAR) has petitioned the...
10 CFR 490.810 - Record retention.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Record retention. 490.810 Section 490.810 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... documentation pertaining to its waiver application and alternative compliance, including petroleum fuel...
10 CFR 490.810 - Record retention.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Record retention. 490.810 Section 490.810 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... documentation pertaining to its waiver application and alternative compliance, including petroleum fuel...
10 CFR 490.810 - Record retention.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Record retention. 490.810 Section 490.810 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... documentation pertaining to its waiver application and alternative compliance, including petroleum fuel...
10 CFR 490.810 - Record retention.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Record retention. 490.810 Section 490.810 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... documentation pertaining to its waiver application and alternative compliance, including petroleum fuel...
10 CFR 490.810 - Record retention.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Record retention. 490.810 Section 490.810 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... documentation pertaining to its waiver application and alternative compliance, including petroleum fuel...
DOE Office of Scientific and Technical Information (OSTI.GOV)
The U.S. Department of Energy (DOE) regulates covered state government and alternative fuel provider fleets, pursuant to the Energy Policy Act of 1992 (EPAct), as amended. Covered fleets may meet their EPAct requirements through one of two compliance methods: Standard Compliance or Alternative Compliance. For model year (MY) 2015, the compliance rate with this program for the more than 3011 reporting fleets was 100%. More than 294 fleets used Standard Compliance and exceeded their aggregate MY 2015 acquisition requirements by 8% through acquisitions alone. The seven covered fleets that used Alternative Compliance exceeded their aggregate MY 2015 petroleum use reductionmore » requirements by 46%.« less
75 FR 67960 - North American Electric Reliability Corporation; Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-04
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket Nos. RM06-16-011] North American Electric Reliability Corporation; Notice of Compliance Filing October 28, 2010. Take notice that on October 25, 2010, the North American Electric Reliability Corporation (NERC), submitted a compliance filing...
77 FR 15096 - Bonneville Power Administration; Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-14
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL11-44-002] Bonneville Power Administration; Notice of Compliance Filing Take notice that on March 6, 2012, the Bonneville Power Administration (Bonneville) submitted a compliance filing with Pro Forma sheets in response to the...
10 CFR 20.2007 - Compliance with environmental and health protection regulations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Compliance with environmental and health protection regulations. 20.2007 Section 20.2007 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Waste Disposal § 20.2007 Compliance with environmental and health protection regulations. Nothing...
10 CFR 20.2007 - Compliance with environmental and health protection regulations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Compliance with environmental and health protection regulations. 20.2007 Section 20.2007 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Waste Disposal § 20.2007 Compliance with environmental and health protection regulations. Nothing...
10 CFR 20.2007 - Compliance with environmental and health protection regulations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Compliance with environmental and health protection regulations. 20.2007 Section 20.2007 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Waste Disposal § 20.2007 Compliance with environmental and health protection regulations. Nothing...
10 CFR 20.2007 - Compliance with environmental and health protection regulations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Compliance with environmental and health protection regulations. 20.2007 Section 20.2007 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Waste Disposal § 20.2007 Compliance with environmental and health protection regulations. Nothing...
10 CFR 20.2007 - Compliance with environmental and health protection regulations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Compliance with environmental and health protection regulations. 20.2007 Section 20.2007 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Waste Disposal § 20.2007 Compliance with environmental and health protection regulations. Nothing...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-09
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD11-1-000] Reliability Monitoring, Enforcement and Compliance Issues; Agenda for the Technical Conference November 2, 2010. The... associated with reliability monitoring, enforcement and compliance. The Commission announced the conference...
Regulatory changes that affect coding for immunotherapy.
Atwater, J Spencer
2006-02-01
During the past decade, a variety of federal regulations have had a significant impact on the way allergen immunotherapy is reimbursed and how Current Procedural Terminology (CPT) codes are used for this purpose. As mandated by the US Congress, the Centers for Medicare and Medicaid Services (CMS) through the Office of the Inspector General (OIG) targeted immunotherapy codes for scrutiny, because they are some of the most frequently used codes. To examine how federal regulations have affected reimbursement for allergy immunotherapy and other allergy services. A review was performed of the OIG survey of allergy immunotherapy and the OIG recommendations on CPT coding compliance guidelines. A preliminary survey found problems with medical appropriateness of allergen immunotherapy. For this reason, the OIG performed a more comprehensive study of 301 physicians using code 95165 to analyze by medical record and billing data whether the new billing rules were being correctly used and found that only 44% of physicians were following the new definition of a billable dose. In the early 1990s, the federal government served notice of its intent to more aggressively identify and prosecute health care providers who improperly billed and collected for medical services. Through the adoption of the 1991 US Sentencing Commission Guidelines, the government sought to enhance compliance by mandating lesser criminal penalties for violating organizations that nevertheless maintained and operated "effective compliance plans." In 2002, the OIG audited health care providers and recouped dollar 14.4 billion in improper payments by Medicare. Between January and June 2003, Medicare excluded 1,241 individual providers and health care entities due to fraudulent billing practices. Federal regulations have significantly affected reimbursement for allergy immunotherapy and other allergy services. Allergists need to be aware of these changes and implement the new recommendations into their practices.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-05
... Transformers AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice and... Transformers, OMB Control Number 1910-5130. The information collection is used by manufacturers or private labelers to report on and certify compliance with energy efficiency standards for distribution transformers...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-04
.... This Rule specifically requires the adoption of a code of ethics by an investment advisor to include... requiring supervised persons to report any violations of the code of ethics promptly to the chief compliance... designated in the code of ethics; and (v) provisions requiring the investment advisor to provide each of the...
75 FR 27772 - Corning Natural Gas Corporation; Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-18
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR09-30-002] Corning Natural Gas Corporation; Notice of Compliance Filing May 11, 2010. Take notice that on May 3, 2010, Corning Natural Gas Corporation, (Corning) filed its Statement of section 311 Operating Conditions in compliance...
Fuel Economy Label and CAFE Data
The Engine and Vehicle Compliance Certification and Fuel Economy Inventory contains measured emissions and fuel economy compliance information for light duty vehicles. Data is collected by EPA to certify compliance with the applicable fuel economy provisions of the Energy Policy and Conservation Act (EPCA) and The Energy Independent Security Act of 2007
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-02
... Conservation Program: Certification, Compliance, and Enforcement for Consumer Products and Commercial and...) Certification. Each manufacturer, before distributing in commerce any basic model of a covered product or.... EERE-2010-BT-CE-0014] RIN 1904-AC23 Energy Conservation Program: Certification, Compliance, and...
77 FR 12277 - City of Banning, CA; Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-29
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. NJ12-3-001] City of Banning, CA; Notice of Compliance Filing Take notice that on February 16, 2012, the City of Banning, CA (Banning) submitted a compliance filing with a revised version of Appendix I to Banning's Transmission...
10 CFR 490.801 - Purpose and scope.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Purpose and scope. 490.801 Section 490.801 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... States and alternative fuel providers to petition for alternative compliance waivers from the alternative...
10 CFR 490.801 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Purpose and scope. 490.801 Section 490.801 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... States and alternative fuel providers to petition for alternative compliance waivers from the alternative...
10 CFR 490.801 - Purpose and scope.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Purpose and scope. 490.801 Section 490.801 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... States and alternative fuel providers to petition for alternative compliance waivers from the alternative...
10 CFR 490.801 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Purpose and scope. 490.801 Section 490.801 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... States and alternative fuel providers to petition for alternative compliance waivers from the alternative...
10 CFR 490.801 - Purpose and scope.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Purpose and scope. 490.801 Section 490.801 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ALTERNATIVE FUEL TRANSPORTATION PROGRAM Alternative Compliance § 490... States and alternative fuel providers to petition for alternative compliance waivers from the alternative...
10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Compliance with requirements for summation of external and internal doses. 20.1202 Section 20.1202 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1202 Compliance with requirements for summation of...
10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Compliance with requirements for summation of external and internal doses. 20.1202 Section 20.1202 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1202 Compliance with requirements for summation of...
10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Compliance with requirements for summation of external and internal doses. 20.1202 Section 20.1202 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1202 Compliance with requirements for summation of...
10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Compliance with requirements for summation of external and internal doses. 20.1202 Section 20.1202 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1202 Compliance with requirements for summation of...
10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Compliance with requirements for summation of external and internal doses. 20.1202 Section 20.1202 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1202 Compliance with requirements for summation of...
10 CFR 76.64 - Denial of certificate or compliance plan.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Denial of certificate or compliance plan. 76.64 Section 76.64 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Certification § 76.64 Denial of certificate or compliance plan. (a) The Director may deny an application for a...
10 CFR 76.62 - Issuance of certificate and/or approval of compliance plan.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 2 2012-01-01 2012-01-01 false Issuance of certificate and/or approval of compliance plan. 76.62 Section 76.62 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Certification § 76.62 Issuance of certificate and/or approval of compliance plan. (a) Upon...
10 CFR 76.64 - Denial of certificate or compliance plan.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 2 2014-01-01 2014-01-01 false Denial of certificate or compliance plan. 76.64 Section 76.64 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Certification § 76.64 Denial of certificate or compliance plan. (a) The Director may deny an application for a...
10 CFR 76.64 - Denial of certificate or compliance plan.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 2 2013-01-01 2013-01-01 false Denial of certificate or compliance plan. 76.64 Section 76.64 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Certification § 76.64 Denial of certificate or compliance plan. (a) The Director may deny an application for a...
10 CFR 76.62 - Issuance of certificate and/or approval of compliance plan.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Issuance of certificate and/or approval of compliance plan. 76.62 Section 76.62 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Certification § 76.62 Issuance of certificate and/or approval of compliance plan. (a) Upon...
10 CFR 76.64 - Denial of certificate or compliance plan.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Denial of certificate or compliance plan. 76.64 Section 76.64 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Certification § 76.64 Denial of certificate or compliance plan. (a) The Director may deny an application for a...
10 CFR 76.62 - Issuance of certificate and/or approval of compliance plan.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 2 2013-01-01 2013-01-01 false Issuance of certificate and/or approval of compliance plan. 76.62 Section 76.62 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Certification § 76.62 Issuance of certificate and/or approval of compliance plan. (a) Upon...
10 CFR 76.64 - Denial of certificate or compliance plan.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 2 2012-01-01 2012-01-01 false Denial of certificate or compliance plan. 76.64 Section 76.64 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Certification § 76.64 Denial of certificate or compliance plan. (a) The Director may deny an application for a...
10 CFR 76.62 - Issuance of certificate and/or approval of compliance plan.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 2 2014-01-01 2014-01-01 false Issuance of certificate and/or approval of compliance plan. 76.62 Section 76.62 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Certification § 76.62 Issuance of certificate and/or approval of compliance plan. (a) Upon...
75 FR 18200 - Monroe Gas Storage Company, LLC; Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-09
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. RP09-447-004] Monroe Gas Storage Company, LLC; Notice of Compliance Filing April 1, 2010. Take notice that on March 23, 2010, Monroe Gas Storage Company, LLC (Monroe), submitted a compliance filing to comply with the February 18...
18 CFR 1b.15 - Non-compliance with compulsory processes.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Non-compliance with compulsory processes. 1b.15 Section 1b.15 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES RULES RELATING TO INVESTIGATIONS § 1b.15 Non-compliance with...
18 CFR 1b.15 - Non-compliance with compulsory processes.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Non-compliance with compulsory processes. 1b.15 Section 1b.15 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES RULES RELATING TO INVESTIGATIONS § 1b.15 Non-compliance with...
18 CFR 1b.15 - Non-compliance with compulsory processes.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Non-compliance with compulsory processes. 1b.15 Section 1b.15 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES RULES RELATING TO INVESTIGATIONS § 1b.15 Non-compliance with...
18 CFR 1b.15 - Non-compliance with compulsory processes.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Non-compliance with compulsory processes. 1b.15 Section 1b.15 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES RULES RELATING TO INVESTIGATIONS § 1b.15 Non-compliance with...
Mobile Source Emissions Regulatory Compliance Data
The Engine and Vehicle Compliance Certification and Fuel Economy Inventory contains measured emissions and fuel economy compliance information for all types of vehicles (mobile sources of air pollution) excluding snowmobile, marine (diesel), and heavy duty engines whichsummary data is updated on an annual basis. Data is collected by EPA to certify compliance with the applicable fuel economy provisions of the Clean Air Act, Energy Policy and Conservation Act (EPCA) and the Energy Independent Security Act (EISA) of 2007.
29 CFR 1910.35 - Compliance with alternate exit-route codes.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 1910.35 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Exit Routes and Emergency Planning § 1910.35...-route provisions of NFPA 101, Life Safety Code, 2009 edition, or the exit-route provisions of the...
Aguayo, Victor M; Ross, Jay S; Kanon, Souleyman; Ouedraogo, Andre N
2003-01-01
Objectives To monitor compliance with the International Code of Marketing of Breastmilk Substitutes in health systems, sales outlets, distribution points, and the news media in Togo and Burkina Faso, west Africa. Design Multisite cross sectional survey. Participants Staff at 43 health facilities and 66 sales outlets and distribution points, 186 health providers, and 105 mothers of infants aged ⩽5 months in 16 cities. Results Six (14%) health facilities had received donations of breast milk substitutes. All donations were being given to mothers free of charge. Health providers in five (12%) health facilities had received free samples of breast milk substitutes for purposes other than professional research or evaluation. Health professionals in five (12%) health facilities had received promotional gifts from manufacturers. Promotional materials of commercial breast milk substitutes were found in seven (16%) health facilities. Special displays to market commercial breast milk substitutes were found in 29 (44%) sales and distribution points. Forty commercial breast milk substitutes violated the labelling standards of the code: 21 were manufactured by Danone, 11 by Nestlé, and eight by other national and international manufacturers. Most (148, 90%) health providers had never heard of the code, and 66 mothers (63%) had never received any counselling on breast feeding by their health providers. Conclusion In west Africa manufacturers are violating the code of marketing of breast milk substitutes. Comparable levels of code violations are observed with (Burkina Faso) or without (Togo) regulating legislation. Legislation must be accompanied by effective information, training, and monitoring systems to ensure that healthcare providers and manufacturers comply with evidence based practice and the code. What is already known on this topicAll member states of the World Health Assembly have reaffirmed their support for the International Code of Marketing of Breastmilk SubstitutesViolations by manufacturers of breast milk substitutes have been reported in industrialised and developing countriesWhat this study addsManufacturers of breast milk substitutes are violating the code in Togo and Burkina FasoThe levels of code violations are similar in a country with (Burkina Faso) and one without (Togo) legislation on the marketing of breast milk substitutesLegislation must be accompanied by effective information, training, and monitoring systems to ensure compliance with the code PMID:12531842
... AAA Foundation Volunteer Opportunities Professional Advancement eAudiology Continuing Education ABA Certification Meetings & Events Employee Resources Research Academia Practice Management Reimbursement Coding Compliance ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-25
... industry guidance contained in Nuclear Energy Institute (NEI) 13-02, ``Industry Guidance for Compliance.... ML13295A225), and Nuclear Energy Institute by letter dated October 18, 2013 (ADAMS Accession No. ML13295A494... NUCLEAR REGULATORY COMMISSION [NRC-2013-0215] Compliance With Order EA-13-109, Order Modifying...
77 FR 48137 - Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-13
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [EL11-22-000, QF11-115-001, QF11-116-001, et al.] Notice of Compliance Filing OREG 1, Inc.; OREG 2, Inc.; OREG 3, Inc.; Docket Nos. EL11-22-000..., OREG 1, Inc., OREG 2, Inc., OREG 3, Inc., and OREG 4, Inc. submitted a supplement to the compliance...
Quantifying the Level of Cross-State Renewable Energy Transactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenny Heeter, Philipp Beiter, Francisco Flores-Espino, David Hurlbut, Chang Liu
2015-02-01
This analysis provides first-ever assessment of the extent to which renewable energy is crossing state borders to be used to meet renewable portfolio standard (RPS) requirements. Two primary methods for data collection are Renewable Energy Certificate (REC) tracking and power flow estimates. Data from regional REC tracking systems, state agencies, and utility compliance reports help understand how cross-state transactions have been used to meet RPS compliance. Data on regional renewable energy flow use generator-specific information primarily sourced from EIA, SNL Energy, and FERC Form 1 filings. The renewable energy examined through this method may or may not have actually beenmore » used to meet RPS compliance.« less
Amoroso, P J; Smith, G S; Bell, N S
2000-04-01
Accurate injury cause data are essential for injury prevention research. U.S. military hospitals, unlike civilian hospitals, use the NATO STANAG system for cause-of-injury coding. Reported deficiencies in civilian injury cause data suggested a need to specifically evaluate the STANAG. The Total Army Injury and Health Outcomes Database (TAIHOD) was used to evaluate worldwide Army injury hospitalizations, especially STANAG Trauma, Injury, and Place of Occurrence coding. We conducted a review of hospital procedures at Tripler Army Medical Center (TAMC) including injury cause and intent coding, potential crossover between acute injuries and musculoskeletal conditions, and data for certain hospital patients who are not true admissions. We also evaluated the use of free-text injury comment fields in three hospitals. Army-wide review of injury records coding revealed full compliance with cause coding, although nonspecific codes appeared to be overused. A small but intensive single hospital records review revealed relatively poor intent coding but good activity and cause coding. Data on specific injury history were present on most acute injury records and 75% of musculoskeletal conditions. Place of Occurrence coding, although inherently nonspecific, was over 80% accurate. Review of text fields produced additional details of the injuries in over 80% of cases. STANAG intent coding specificity was poor, while coding of cause of injury was at least comparable to civilian systems. The strengths of military hospital data systems are an exceptionally high compliance with injury cause coding, the availability of free text, and capture of all population hospital records without regard to work-relatedness. Simple changes in procedures could greatly improve data quality.
Process improvement program evolves into compliance program at an integrated delivery system.
Tyk, R C; Hylton, P G
1998-09-01
An integrated delivery system discovered questionable practices when it undertook a process-improvement initiative for its revenue-to-cash cycle. These discoveries served as a wake-up call to the organization that it needed to develop a comprehensive corporate compliance program. The organization engaged legal counsel to help it establish such a program. A corporate compliance officer was hired, and a compliance committee was set up. They worked with counsel to develop the structure and substance of the program and establish a corporate code of conduct that became a part of the organization's policies and procedures. Teams were formed in various areas of the organization to review compliance-related activities and suggest improvements. Clinical and nonclinical staff attended mandatory educational sessions about the program. By approaching compliance systematically, the organization has put itself in an excellent position to avoid fraudulent and abusive activities- and the government scrutiny they invite.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-04
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. RM10-11-000] Integration of Variable Energy Resources; Notice Of Filing Procedures for Order No. 764 Electronic Compliance Filings Take notice of the following filing procedures with respect to compliance obligations in Integration of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hathcock, Charles Dean; Keller, David Charles; Sartor, Karla A.
This floodplain assessment was prepared in accordance with 10 Code of Federal Regulations (CFR) 1022 Compliance with Floodplain and Wetland Environmental Review Requirements, which was promulgated to implement the U.S. Department of Energy (DOE) requirements under Executive Order 11988 Floodplain Management and Executive Order 11990 Wetlands Protection. According to 10 CFR 1022, a 100-year floodplain is defined as “the lowlands adjoining inland and coastal waters and relatively flat areas and flood prone areas of offshore islands.” In this action, DOE is proposing to control the run-on of storm water by slowing water velocity and managing sediments from the upper portionsmore » of the Cañon de Valle watershed on Los Alamos National Laboratory (LANL) property with a number of new watershed controls near and within the 100-year floodplain (hereafter floodplain). The proposed work will comply with requirements under the Settlement Agreement and Stipulated Final Compliance Order (Settlement Agreement) Number HWB-14-20.« less
Ergin, Ahmet; Hatipoğlu, Celile; Bozkurt, Ali Ihsan; Erdoğan, Aslı; Güler, Serdar; Ince, Gülberat; Kavurgacı, Nuran; Oz, Ahmet; Yeniay, Mustafa K
2013-01-01
The aim of this study was to determine the compliance status of product labels regarding Article 9 of the International Code on Marketing of Breast-milk Substitutes (the Code) in Denizli province, Turkey. A cross-sectional study design was employed to determine the compliance status. The product labels were obtained from a convenience sample of five supermarkets, one store and 5 pharmacies in the City centre and district of Honaz. Using a data collection form prepared by previously published studies, data were collected between July 26, 2010 and August 06, 2010. Data collection form included 13 criteria. In addition, we checked the boxes for the availability of a Turkish written label. Forty product labels of 7 companies were reached and evaluated. These products consisted of 83.0% of the products marketed by these companies in Turkey. Thirty seven (92.5%) of the labels violated Article 9 of the Code in terms of one or more criteria. Thirty four (85.0%) of the labels had photos or pictures idealizing the use of infant formula. Nine (22.5%) had a photo, a picture or any representation of an infant, and five (12.5%) had text which idealize the use of infant formula or discouraging breastfeeding. Eight (20%) did not state that breastfeeding is the best. Four (10%) had a term such as 'similar to breast milk or human milk'. In conclusion, the majority of the product labels of breast milk substitutes marketed in our country violate the Code. It is appropriate that the Turkish Ministry of Health, medical organizations, companies, and NGOs work more actively to increase awareness of this issue.
Emery, R J; Charlton, M A; Orders, A B; Hernandez, M
2001-02-01
An enhanced coding system for the characterization of notices of violation (NOV's) issued to radiation permit holders in the State of Texas was developed based on a series of fault tree analyses serving to identify a set of common causes. The coding system enhancement was retroactively applied to a representative sample (n = 185) of NOV's issued to specific licensees of radioactive materials in Texas during calendar year 1999. The results obtained were then compared to the currently available summary NOV information for the same year. In addition to identifying the most common NOV's, the enhanced coding system revealed that approximately 70% of the sampled NOV's were issued for non-compliance with a specific regulation as opposed to a permit condition. Furthermore, an underlying cause of 94% of the NOV's was the failure on the part of the licensee to execute a specific task. The findings suggest that opportunities exist to improve permit holder compliance through various means, including the creation of summaries which detail specific tasks to be completed, and revising training programs with more focus on the identification and scheduling of permit-related requirements. Broad application of these results is cautioned due to the bias associated with the restricted scope of the project.
Biennial Environmental Compliance Report (2010-2012)
This Biennial Environmental Compliance Report (BECR) documents United States (U.S.) Department of Energy (DOE) compliance with environmental regulations applicable to the Waste Isolation Pilot Plant (WIPP) facility.
Building energy simulation in real time through an open standard interface
Pang, Xiufeng; Nouidui, Thierry S.; Wetter, Michael; ...
2015-10-20
Building energy models (BEMs) are typically used for design and code compliance for new buildings and in the renovation of existing buildings to predict energy use. We present the increasing adoption of BEM as standard practice in the building industry presents an opportunity to extend the use of BEMs into construction, commissioning and operation. In 2009, the authors developed a real-time simulation framework to execute an EnergyPlus model in real time to improve building operation. This paper reports an enhancement of that real-time energy simulation framework. The previous version only works with software tools that implement the custom co-simulation interfacemore » of the Building Controls Virtual Test Bed (BCVTB), such as EnergyPlus, Dymola and TRNSYS. The new version uses an open standard interface, the Functional Mockup Interface (FMI), to provide a generic interface to any application that supports the FMI protocol. In addition, the new version utilizes the Simple Measurement and Actuation Profile (sMAP) tool as the data acquisition system to acquire, store and present data. Lastly, this paper introduces the updated architecture of the real-time simulation framework using FMI and presents proof-of-concept demonstration results which validate the new framework.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-07
...] Draft Guidance for Industry: Bar Code Label Requirements-- Questions and Answers (Question 12 Update... Administration (FDA) is announcing the availability of a draft document entitled ``Guidance for Industry: Bar... guidance provides you, manufacturers of a licensed vaccine, with advice concerning compliance with the bar...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-27
....203-13, Contractor Code of Business Ethics and Conduct. DATES: Effective Date: September 27, 2010. FOR... Acquisition Regulation (FAR) Case 2007-006, ``Contractor Business Ethics Compliance Program and Disclosure... date of December 12, 2008. The contract clause entitled ``Contractor Code of Business Ethics and...
76 FR 32989 - Request for Certification of Compliance-Rural Industrialization Loan and Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-07
.../Purpose: The loan, guarantee, or grant application is to obtain financing for infrastructure updates... will be located in Burlington, Iowa. The NAICS industry code for this enterprise is: 311812 (commercial..., Assistant Secretary for Employment and Training. [FR Doc. 2011-13937 Filed 6-6-11; 8:45 am] BILLING CODE...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-07
...] Compliance Policy Guide Sec. 390.500 Definition of ``High-Voltage Vacuum Switch''--21 CFR 1002.61(a)(3) and... Sec. 390.500 Definition of ``High-Voltage Vacuum Switch''--21 CFR 1002.61(a)(3) and (b)(2) (CPG Sec.... 2010-30677 Filed 12-6-10; 8:45 am] BILLING CODE 4160-01-P ...
78 FR 28211 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-14
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice.... Applicants: Duke Energy Carolinas, LLC. Description: Compliance Filing ER13-959 to be effective 6/1/2011.... Description: OATT Revisions to Attachment N--LGIA and Attachment O--SGIA Compliance Filing to be effective 3/1...
10 CFR 820.40 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Purpose and scope. 820.40 Section 820.40 Energy DEPARTMENT OF ENERGY PROCEDURAL RULES FOR DOE NUCLEAR ACTIVITIES Compliance Orders § 820.40 Purpose and scope. This subpart provides for the issuance of Compliance Orders to prevent, rectify or penalize violations...
10 CFR 820.40 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Purpose and scope. 820.40 Section 820.40 Energy DEPARTMENT OF ENERGY PROCEDURAL RULES FOR DOE NUCLEAR ACTIVITIES Compliance Orders § 820.40 Purpose and scope. This subpart provides for the issuance of Compliance Orders to prevent, rectify or penalize violations...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-02
... DEPARTMENT OF ENERGY 10 CFR Parts 429 and 430 [Docket No. EERE-2010-BT-CE-0014] RIN 1904-AC23 Energy Conservation Program: Certification, Compliance, and Enforcement for Consumer Products and Commercial and Industrial Equipment; Correction Correction In rule document 2011-10401 appearing on pages...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-05
.... EERE-2010-BT-CE-0014] RIN 1904-AC24 Energy Conservation Program: Certification, Compliance, and Enforcement for Consumer Products and Commercial and Industrial Equipment Correction In proposed rule document...
Compliance in peritoneal dialysis: a qualitative study of renal nurses.
McCarthy, Alexandra; Cook, Peta S; Fairweather, Carrie; Shaban, Ramon; Martin-McDonald, Kristine
2009-06-01
End-stage renal failure is a life-threatening condition, often treated with home-based peritoneal dialysis (PD). PD is a demanding regimen, and the patients who practise it must make numerous lifestyle changes and learn complicated biomedical techniques. In our experience, the renal nurses who provide most PD education frequently express concerns that patient compliance with their teaching is poor. These concerns are mirrored in the renal literature. It has been argued that the perceived failure of health professionals to improve compliance rates with PD regimens is because 'compliance' itself has never been adequately conceptualized or defined; thus, it is difficult to operationalize and quantify. This paper examines how a group of Australian renal nurses construct patient compliance with PD therapy. These empirical data illuminate how PD compliance operates in one practice setting; how it is characterized by multiple and often competing energies; and how ultimately it might be pointless to try to tame 'compliance' through rigid definitions and measurement, or to rigidly enforce it in PD patients. The energies involved are too fractious and might be better spent, as many of the more experienced nurses in this study argue, in augmenting the energies that do work well together to improve patient outcomes.
Quantifying the Level of Cross-State Renewable Energy Transactions (Presentation)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heeter, J.; Beiter, P.; Flores, F.
2015-02-01
This presentation and associated spreadsheet examine the level of cross-state renewable energy transactions. Most state renewable portfolio standard (RPS) policies allow for out-of-state renewable energy or renewable energy certificates to count towards compliance. This analysis focuses on compliance for 2012 and provides stakeholders with an understanding of the extent to which RPSs are being met.
Regulatory Information By Sector
Find environmental regulatory, compliance, & enforcement information for various business, industry and government sectors, listed by NAICS code. Sectors include agriculture, automotive, petroleum manufacturing, oil & gas extraction & other manufacturing
Environmental Compliance Audit Handbook (ECAH): U.S. Fish and Wildlife Service (FWS) (Revision)
1999-09-01
with FWS, began research on this handbook. The concept was to combine the Code of Federal Regulations with good management practices and risk... The numbers of environmental laws and regulations have continued to grow in the United States, making compliance with these regulations increasingly...violations by the U.S. Environmental Protection Agency (USEPA). Beginning in 1993, the U.S. Army Construction Engineering Research Laboratory, in cooperation
Environmental Compliance Assessment for Army Reserves (ECAAR)
1991-11-01
The number of environmental laws and regulations has continued to grow in the United States and worldwide, making compliance with these regulations...they became notices of violation. The concept was to combine Code of Federal Regulations and Army environmental regulations, with good management...items or operations to review, and would list a point of contact for that item to help assessors review the questions, or protocols, quickly and easily
77 FR 31647 - Request for Certification of Compliance-Rural Industrialization Loan and Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-29
... includes the retrofit and build-out of the facility, which will be located in Mt. Pleasant, Pennsylvania. The NAICS industry code for this enterprise is: 335911 (storage battery manufacturing). DATES: All..., Assistant Secretary for Employment and Training. [FR Doc. 2012-12917 Filed 5-25-12; 8:45 am] BILLING CODE...
77 FR 1955 - Request for Certification of Compliance-Rural Industrialization Loan and Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-12
... Product/Purpose: The loan, guarantee, or grant application is to finance building construction and to... Dakota. The NAICS industry code for this enterprise is: 311611 (beef produced in slaughtering plants..., Assistant Secretary for Employment and Training. [FR Doc. 2012-448 Filed 1-11-12; 8:45 am] BILLING CODE 4510...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-04
... specifically requires the adoption of a code of ethics by an investment advisor to include, at a minimum: (i... persons to report any violations of the code of ethics promptly to the chief compliance officer (``CCO... of ethics; and (v) provisions requiring the investment advisor to provide each of the supervised...
Code of Federal Regulations, 2010 CFR
2010-10-01
... ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Federal Compliance With Right-To-Know Laws and Pollution Prevention Requirements 23.1000 Scope...) Compliance with right-to-know laws and pollution prevention requirements; (b) Implementation of an...
Adams, Diane L.; Norman, Helen; Burroughs, Valentine J.
2002-01-01
Medical practice today, more than ever before, places greater demands on physicians to see more patients, provide more complex medical services and adhere to stricter regulatory rules, leaving little time for coding and billing. Yet, the need to adequately document medical records, appropriately apply billing codes and accurately charge insurers for medical services is essential to the medical practice's financial condition. Many physicians rely on office staff and billing companies to process their medical bills without ever reviewing the bills before they are submitted for payment. Some physicians may not be receiving the payment they deserve when they do not sufficiently oversee the medical practice's coding and billing patterns. This article emphasizes the importance of monitoring and auditing medical record documentation and coding application as a strategy for achieving compliance and reducing billing errors. When medical bills are submitted with missing and incorrect information, they may result in unpaid claims and loss of revenue to physicians. Addressing Medical Audits, Part I--A Strategy for Achieving Compliance--CMS, JCAHO, NCQA, published January 2002 in the Journal of the National Medical Association, stressed the importance of preparing the medical practice for audits. The article highlighted steps the medical practice can take to prepare for audits and presented examples of guidelines used by regulatory agencies to conduct both medical and financial audits. The Medicare Integrity Program was cited as an example of guidelines used by regulators to identify coding errors during an audit and deny payment to providers when improper billing occurs. For each denied claim, payments owed to the medical practice are are also denied. Health care is, no doubt, a costly endeavor for health care providers, consumers and insurers. The potential risk to physicians for improper billing may include loss of revenue, fraud investigations, financial sanction, disciplinary action and exclusion from participation in government programs. Part II of this article recommends an approach for assessing potential risk, preventing improper billing, and improving financial management of the medical practice. Images p432-a PMID:12078924
Schulze Raestrup, U; Grams, A; Smektala, R
2008-02-01
Whereas the Scottish guidelines are audited annually, nobody evaluates guideline compliance in Germany. Thus, can external quality assurance data pursuant to section 137 of the German Social Code Book V be suitable for auditing guideline compliance? From North Rhine Westphalia, a total of 48,831 cases of femoral fractures near the hip joint were evaluated. Compliance with the guidelines was determined based on preoperative hospital stay, thrombosis, and antibiotic prophylaxis. Guideline rationale was reviewed in terms of mortality and thromboembolism rate. Sixty-four percent of the interventions were performed in a timely manner. Thrombosis prophylaxis was given in 99% of cases. Antibiotics were given as a single shot. There was no connection between mortality and thromboembolism rates or time to surgery. Guideline compliance is similar in German and Scotland. The external quality assurance data are suitable for evaluating guideline compliance. The literature recommends a short time to surgery. Given the short observation period, it was not possible to demonstrate any improvement in outcomes.
Kok, Rianne; Bakermans-Kranenburg, Marian J; van Ijzendoorn, Marinus H; Velders, Fleur P; Linting, Mariëlle; Jaddoe, Vincent W V; Hofman, Albert; Verhulst, Frank C; Tiemeier, Henning
2013-07-01
Maternal discipline is an important predictor of child committed compliance. Maternal stress can affect both parenting and child development. In a large population-based cohort study (N = 613) we examined whether maternal discipline mediated the association between maternal stress during pregnancy and child compliance, and whether COMT or DRD4 polymorphisms moderated the association between maternal discipline and child compliance. Family-related and general stress were measured through maternal self-report and genetic material was collected through cord blood sampling at birth. Mother-child dyads were observed at 36 months in disciplinary tasks in which the child was not allowed to touch attractive toys. Maternal discipline and child compliance were observed in two different tasks and independently coded. The association between family stress during pregnancy and child committed compliance was mediated by maternal positive discipline. Children with more COMT Met alleles seemed more susceptible to maternal positive discipline than children with more COMT Val alleles. Copyright © 2012 Wiley Periodicals, Inc.
Quick Response codes for surgical safety: a prospective pilot study.
Dixon, Jennifer L; Smythe, William Roy; Momsen, Lara S; Jupiter, Daniel; Papaconstantinou, Harry T
2013-09-01
Surgical safety programs have been shown to reduce patient harm; however, there is variable compliance. The purpose of this study is to determine if innovative technology such as Quick Response (QR) codes can facilitate surgical safety initiatives. We prospectively evaluated the use of QR codes during the surgical time-out for 40 operations. Feasibility and accuracy were assessed. Perceptions of the current time-out process and the QR code application were evaluated through surveys using a 5-point Likert scale and binomial yes or no questions. At baseline (n = 53), survey results from the surgical team agreed or strongly agreed that the current time-out process was efficient (64%), easy to use (77%), and provided clear information (89%). However, 65% of surgeons felt that process improvements were needed. Thirty-seven of 40 (92.5%) QR codes scanned successfully, of which 100% were accurate. Three scan failures resulted from excessive curvature or wrinkling of the QR code label on the body. Follow-up survey results (n = 33) showed that the surgical team agreed or strongly agreed that the QR program was clearer (70%), easier to use (57%), and more accurate (84%). Seventy-four percent preferred the QR system to the current time-out process. QR codes accurately transmit patient information during the time-out procedure and are preferred to the current process by surgical team members. The novel application of this technology may improve compliance, accuracy, and outcomes. Copyright © 2013 Elsevier Inc. All rights reserved.
7 CFR 1436.5 - Eligible borrowers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... with any applicable local zoning, land use, and building codes for the applicable farm storage facility... has all peril structural insurance; (10) Demonstrates compliance with the National Environmental...
24 CFR 905.10 - Capital Fund formula (CFF).
Code of Federal Regulations, 2013 CFR
2013-04-01
... projects; (ii) Vacancy reduction; (iii) Addressing deferred maintenance needs and the replacement of obsolete utility systems and dwelling equipment; (iv) Planned code compliance; (v) Management improvements...
24 CFR 905.10 - Capital Fund formula (CFF).
Code of Federal Regulations, 2012 CFR
2012-04-01
... projects; (ii) Vacancy reduction; (iii) Addressing deferred maintenance needs and the replacement of obsolete utility systems and dwelling equipment; (iv) Planned code compliance; (v) Management improvements...
Lindholm, Henrik; Egels-Zandén, Niklas; Rudén, Christina
2016-10-01
In managing chemical risks to the environment and human health in supply chains, voluntary corporate social responsibility (CSR) measures, such as auditing code of conduct compliance, play an important role. To examine how well suppliers' chemical health and safety performance complies with buyers' CSR policies and whether audited factories improve their performance. CSR audits (n = 288) of garment factories conducted by Fair Wear Foundation (FWF), an independent non-profit organization, were analyzed using descriptive statistics and statistical modeling. Forty-three per cent of factories did not comply with the FWF code of conduct, i.e. received remarks on chemical safety. Only among factories audited 10 or more times was there a significant increase in the number of factories receiving no remarks. Compliance with chemical safety requirements in garment supply chains is low and auditing is statistically correlated with improvements only at factories that have undergone numerous audits.
2016-01-01
Background In managing chemical risks to the environment and human health in supply chains, voluntary corporate social responsibility (CSR) measures, such as auditing code of conduct compliance, play an important role. Objectives To examine how well suppliers’ chemical health and safety performance complies with buyers’ CSR policies and whether audited factories improve their performance. Methods CSR audits (n = 288) of garment factories conducted by Fair Wear Foundation (FWF), an independent non-profit organization, were analyzed using descriptive statistics and statistical modeling. Results Forty-three per cent of factories did not comply with the FWF code of conduct, i.e. received remarks on chemical safety. Only among factories audited 10 or more times was there a significant increase in the number of factories receiving no remarks. Conclusions Compliance with chemical safety requirements in garment supply chains is low and auditing is statistically correlated with improvements only at factories that have undergone numerous audits. PMID:27611103
Design Compliance Matrices to ANSI and OSHA
DOE Office of Scientific and Technical Information (OSTI.GOV)
BENDIXSEN, R.B.
2000-04-03
U.S. Department of Energy Letter 98-SFD-028 requested Fluor Daniel Hanford, Inc. to provide clarifications as to compliance with ANSI 57.1, 57.2, 57.9, and 29 CFR 1910.179 (OSHA), in the form of an item-by-item compliance matrix, for the CSB. This Supporting Document contains Fluor Daniel, Inc.'s response for use by Fluor Daniel Hanford, Inc. regarding the clarifications requested by the U.S. Department of Energy.
Fleet Compliance Annual Report: Model Year 2015, Fiscal Year 2016
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The U.S. Department of Energy (DOE) regulates covered state government and alternative fuel provider fleets, pursuant to the Energy Policy Act of 1992 (EPAct), as amended. This report details compliance for model year 2015, fiscal year 2016.
25 CFR 224.120 - What action may the Director take to ensure compliance with a TERA?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false What action may the Director take to ensure compliance with a TERA? 224.120 Section 224.120 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ENERGY AND MINERALS TRIBAL ENERGY RESOURCE AGREEMENTS UNDER THE INDIAN TRIBAL ENERGY DEVELOPMENT AND SELF...
25 CFR 224.120 - What action may the Director take to ensure compliance with a TERA?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false What action may the Director take to ensure compliance with a TERA? 224.120 Section 224.120 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ENERGY AND MINERALS TRIBAL ENERGY RESOURCE AGREEMENTS UNDER THE INDIAN TRIBAL ENERGY DEVELOPMENT AND SELF...
Approximate minimum-time trajectories for 2-link flexible manipulators
NASA Technical Reports Server (NTRS)
Eisler, G. R.; Segalman, D. J.; Robinett, R. D.
1989-01-01
Powell's nonlinear programming code, VF02AD, was used to generate approximate minimum-time tip trajectories for 2-link semi-rigid and flexible manipulator movements in the horizontal plane. The manipulator is modeled with an efficient finite-element scheme for an n-link, m-joint system with horizontal-plane bending only. Constraints on the trajectory include boundary conditions on position and energy for a rest-to-rest maneuver, straight-line tracking between boundary positions, and motor torque limits. Trajectory comparisons utilize a change in the link stiffness, EI, to transition from the semi-rigid to flexible case. Results show the level of compliance necessary to excite significant modal behavior. Quiescence of the final configuration is examined with the finite-element model.
Annual Change Report 2006/2007
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington Regulatory and Environmental Services; Washington TRU Solutions LLC
2007-11-16
As part of continuing compliance, the U.S. Environmental Protection Agency (EPA) requires the U.S. Department of Energy (DOE) to provide information on any change in conditions or activities pertaining to the disposal system since the most recent compliance application. This requirement is identified in Title 40 Code of Federal Regulations (CFR), Section 194.4(b)(4), which states: "No later than six months after the administrator issues a certification, and at least annually thereafter, the Department shall report to the Administrator, in writing, any changes in conditions or activities pertaining to the disposal system that were not required to be reported by paragraphmore » (b)(3) of this section and that differ from information contained in the most recent compliance application." In meeting the requirement, the DOE provides an annual report each November of all applicable changes under the above requirement. This annual report informs the EPA of changes to information in the most recent compliance recertification (the 2004 Compliance Recertification). Significant planned changes must be reported to the EPA prior to implementation by the DOE. In addition, Title 40 CFR, Section 194.4(b)(3) requires that significant unplanned changes be reported to the EPA within 24 hours or ten days, depending on the severity of the activity or condition. To date, there have been no significant unplanned changes to the certification basis. Planned changes have been submitted on an individual basis. All other changes are reported annually. Changes in activities or conditions are reviewed to determine if 40 CFR Section 194.4(b)(3) reporting is necessary. As indicated above, no significant unplanned changes were identified for the time period covered by this report. The enclosed tables list those items identified for reporting under 40 CFR Section 194.4(b)(4). The majority of the items described in this report are inspections, reports, and modifications to written plans and procedures for WIPP operations.« less
Environmental factor(tm) system: RCRA hazardous waste handler information (on CD-ROM). Data file
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-11-01
Environmental Factor(trademark) RCRA Hazardous Waste Handler Information on CD-ROM unleashes the invaluable information found in two key EPA data sources on hazardous waste handlers and offers cradle-to-grave waste tracking. It`s easy to search and display: (1) Permit status, design capacity, and compliance history for facilities found in the EPA Research Conservation and Recovery Information System (RCRIS) program tracking database; (2) Detailed information on hazardous wastes generation, management, and minimization by companies who are large quantity generators; and (3) Data on the waste management practices of treatment, storage, and disposal (TSD) facilities from the EPA Biennial Reporting System which is collectedmore » every other year. Environmental Factor`s powerful database retrieval system lets you: (1) Search for RCRA facilities by permit type, SIC code, waste codes, corrective action, or violation information, TSD status, generator and transporter status, and more. (2) View compliance information - dates of evaluation, violation, enforcement, and corrective action. (3) Lookup facilities by waste processing categories of marketing, transporting, processing, and energy recovery. (4) Use owner/operator information and names, titles, and telephone numbers of project managers for prospecting. (5) Browse detailed data on TSD facility and large quantity generators` activities such as onsite waste treatment, disposal, or recycling, offsite waste received, and waste generation and management. The product contains databases, search and retrieval software on two CD-ROMs, an installation diskette and User`s Guide. Environmental Factor has online context-sensitive help from any screen and a printed User`s Guide describing installation and step-by-step procedures for searching, retrieving, and exporting.« less
10 CFR Appendix C to Subpart B of... - Compliance Certification
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND INDUSTRIAL EQUIPMENT Electric Motors Pt. 431, Subpt. B, App. C Appendix C to Subpart B of Part 431—Compliance Certification Certification of Compliance With Energy Efficiency Standards for Electric Motors... Company (the “company”): 2. Name(s) to be Marked on Electric Motors to Which this Compliance Certification...
10 CFR Appendix C to Subpart B of... - Compliance Certification
Code of Federal Regulations, 2014 CFR
2014-01-01
... AND INDUSTRIAL EQUIPMENT Electric Motors Pt. 431, Subpt. B, App. C Appendix C to Subpart B of Part 431—Compliance Certification Certification of Compliance With Energy Efficiency Standards for Electric Motors...”): 2. Name(s) to be Marked on Electric Motors to Which this Compliance Certification Applies: 3. If...
10 CFR Appendix C to Subpart B of... - Compliance Certification
Code of Federal Regulations, 2013 CFR
2013-01-01
... AND INDUSTRIAL EQUIPMENT Electric Motors Pt. 431, Subpt. B, App. C Appendix C to Subpart B of Part 431—Compliance Certification Certification of Compliance With Energy Efficiency Standards for Electric Motors...”): 2. Name(s) to be Marked on Electric Motors to Which this Compliance Certification Applies: 3. If...
10 CFR Appendix C to Subpart B of... - Compliance Certification
Code of Federal Regulations, 2012 CFR
2012-01-01
... AND INDUSTRIAL EQUIPMENT Electric Motors Pt. 431, Subpt. B, App. C Appendix C to Subpart B of Part 431—Compliance Certification Certification of Compliance With Energy Efficiency Standards for Electric Motors...”): 2. Name(s) to be Marked on Electric Motors to Which this Compliance Certification Applies: 3. If...
ISO-IEC MPEG-2 software video codec
NASA Astrophysics Data System (ADS)
Eckart, Stefan; Fogg, Chad E.
1995-04-01
Part 5 of the International Standard ISO/IEC 13818 `Generic Coding of Moving Pictures and Associated Audio' (MPEG-2) is a Technical Report, a sample software implementation of the procedures in parts 1, 2 and 3 of the standard (systems, video, and audio). This paper focuses on the video software, which gives an example of a fully compliant implementation of the standard and of a good video quality encoder, and serves as a tool for compliance testing. The implementation and some of the development aspects of the codec are described. The encoder is based on Test Model 5 (TM5), one of the best, published, non-proprietary coding models, which was used during MPEG-2 collaborative stage to evaluate proposed algorithms and to verify the syntax. The most important part of the Test Model is controlling the quantization parameter based on the image content and bit rate constraints under both signal-to-noise and psycho-optical aspects. The decoder has been successfully tested for compliance with the MPEG-2 standard, using the ISO/IEC MPEG verification and compliance bitstream test suites as stimuli.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-05
... Information Collection; Comment Request; Certification, Compliance, and Enforcement Requirements for Consumer Products and Certain Commercial and Industrial Equipment AGENCY: Office of Energy Efficiency and Renewable... (EPCA) establishes energy and water conservation standards and test procedures for consumer products and...
NASA Technical Reports Server (NTRS)
Salpekar, S. A.; Raju, I. S.; O'Brien, T. K.
1988-01-01
Two-dimensional finite-element analysis of the end-notched flexure specimen was performed using 8-node isoparametric, parabolic elements to evaluate compliance and mode II strain energy release rates, G sub II. The G sub II values were computed using two different techniques: the virtual crack-closure technique (VCCT) and the rate of change of compliance with crack length (compliance derivative method). The analysis was performed for various crack-length-to-semi-span (a/L) ratios ranging from 0.2 to 0.9. Three material systems representing a wide range of material properties were analyzed. The compliance and strain energy release rates of the specimen calculated with the present finite-element analysis agree very well with beam theory equations including transverse shear. The G sub II values calculated using the compliance derivative method compared extremely well with those calculated using the VCCT. The G sub II values obtained by the compliance derivative method using the top or bottom beam deflections agreed closely with each other. The strain energy release rates from a plane-stress analysis were higher than the plane-strain values by only a small percentage, indicating that either assumption may be used in the analysis. The G sub II values for one material system calculated from the finte-element analysis agreed with one solution in the literature and disagreed with the other solution in the literature.
NASA Technical Reports Server (NTRS)
Salpekar, S. A.; Raju, I. S.; Obrien, T. K.
1987-01-01
Two-dimensional finite-element analysis of the end-notched flexure specimen was performed using 8-node isoparametric, parabolic elements to evaluate compliance and mode II strain energy release rates, G sub II. The G sub II values were computed using two different techniques: the virtural crack-closure technique (VCCT) and the rate of change of compliance with crack length (compliance derivative method). The analysis was performed for various crack-length-to-semi-span (a/L) ratios ranging from 0.2 to 0.9. Three material systems representing a wide range of material properties were analyzed. The compliance and strain energy release rates of the specimen calculated with the present finite-element analysis agree very well with beam theory equations including transverse shear. The G sub II values calculated using the compliance derivative method compared extremely well with those calculated using the VCCT. The G sub II values obtained by the compliance derivative method using the top or bottom beam deflections agreed closely with each other. The strain energy release rates from a plane-stress analysis were higher than the plane-strain values by only a small percentage, indicating that either assumption may be used in the analysis. The G sub II values for one material system calculated from the finite-element analysis agreed with one solution in the literature and disagreed with the other solution in the literature.
31 CFR 11.6 - Terms of permit.
Code of Federal Regulations, 2012 CFR
2012-07-01
... vending facilities shall be operated in compliance with applicable health, sanitation, and building codes... normal cleaning, maintenance, and repair of the building structure in and adjacent to the vending...
31 CFR 11.6 - Terms of permit.
Code of Federal Regulations, 2011 CFR
2011-07-01
... vending facilities shall be operated in compliance with applicable health, sanitation, and building codes... normal cleaning, maintenance, and repair of the building structure in and adjacent to the vending...
31 CFR 11.6 - Terms of permit.
Code of Federal Regulations, 2014 CFR
2014-07-01
... vending facilities shall be operated in compliance with applicable health, sanitation, and building codes... normal cleaning, maintenance, and repair of the building structure in and adjacent to the vending...
ERIC Educational Resources Information Center
Cray, Dan
1994-01-01
Discusses the tradeoff of speed and movability versus costs when using relocatable buildings to solve educational space needs. Concluding comments address building-code compliance issues driving up expenses and impacting facility planning.(GR)
25 CFR 224.117 - Must the Director make a determination of the tribe's compliance with a TERA?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false Must the Director make a determination of the tribe's compliance with a TERA? 224.117 Section 224.117 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ENERGY AND MINERALS TRIBAL ENERGY RESOURCE AGREEMENTS UNDER THE INDIAN TRIBAL ENERGY DEVELOPMENT AND SELF...
25 CFR 224.117 - Must the Director make a determination of the tribe's compliance with a TERA?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false Must the Director make a determination of the tribe's compliance with a TERA? 224.117 Section 224.117 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ENERGY AND MINERALS TRIBAL ENERGY RESOURCE AGREEMENTS UNDER THE INDIAN TRIBAL ENERGY DEVELOPMENT AND SELF...
18 CFR 154.203 - Compliance filings.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Compliance filings. 154.203 Section 154.203 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER NATURAL GAS ACT RATE SCHEDULES AND TARIFFS Procedures for Changing...
18 CFR 154.203 - Compliance filings.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Compliance filings. 154.203 Section 154.203 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER NATURAL GAS ACT RATE SCHEDULES AND TARIFFS Procedures for Changing...
18 CFR 154.203 - Compliance filings.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Compliance filings. 154.203 Section 154.203 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER NATURAL GAS ACT RATE SCHEDULES AND TARIFFS Procedures for Changing...
18 CFR 154.203 - Compliance filings.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Compliance filings. 154.203 Section 154.203 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER NATURAL GAS ACT RATE SCHEDULES AND TARIFFS Procedures for Changing...
18 CFR 154.203 - Compliance filings.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Compliance filings. 154.203 Section 154.203 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER NATURAL GAS ACT RATE SCHEDULES AND TARIFFS Procedures for Changing...
77 FR 64502 - Notice of Compliance Filings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-22
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Compliance Filings Docket Nos. Northwestern Corporation (South Dakota). ER13-62-000 PacificCorp ER13-64-000 Deseret Generation & Transmission ER13-65-000 Cooperative, Inc.. Northwestern Corporation (Montana)...... ER13-67-000 Portland General...
Effects of cross-bridge compliance on the force-velocity relationship and muscle power output
Fenwick, Axel J.; Wood, Alexander M.
2017-01-01
Muscles produce force and power by utilizing chemical energy through ATP hydrolysis. During concentric contractions (shortening), muscles generate less force compared to isometric contractions, but consume greater amounts of energy as shortening velocity increases. Conversely, more force is generated and less energy is consumed during eccentric muscle contractions (lengthening). This relationship between force, energy use, and the velocity of contraction has important implications for understanding muscle efficiency, but the molecular mechanisms underlying this behavior remain poorly understood. Here we used spatially-explicit, multi-filament models of Ca2+-regulated force production within a half-sarcomere to simulate how force production, energy utilization, and the number of bound cross-bridges are affected by dynamic changes in sarcomere length. These computational simulations show that cross-bridge binding increased during slow-velocity concentric and eccentric contractions, compared to isometric contractions. Over the full ranges of velocities that we simulated, cross-bridge cycling and energy utilization (i.e. ATPase rates) increased during shortening, and decreased during lengthening. These findings are consistent with the Fenn effect, but arise from a complicated relationship between velocity-dependent cross-bridge recruitment and cross-bridge cycling kinetics. We also investigated how force production, power output, and energy utilization varied with cross-bridge and myofilament compliance, which is impossible to address under typical experimental conditions. These important simulations show that increasing cross-bridge compliance resulted in greater cross-bridge binding and ATPase activity, but less force was generated per cross-bridge and throughout the sarcomere. These data indicate that the efficiency of force production decreases in a velocity-dependent manner, and that this behavior is sensitive to cross-bridge compliance. In contrast, significant effects of myofilament compliance on force production were only observed during isometric contractions, suggesting that changes in myofilament compliance may not influence power output during non-isometric contractions as greatly as changes in cross-bridge compliance. These findings advance our understanding of how cross-bridge and myofilament properties underlie velocity-dependent changes in contractile efficiency during muscle movement. PMID:29284062
Effects of cross-bridge compliance on the force-velocity relationship and muscle power output.
Fenwick, Axel J; Wood, Alexander M; Tanner, Bertrand C W
2017-01-01
Muscles produce force and power by utilizing chemical energy through ATP hydrolysis. During concentric contractions (shortening), muscles generate less force compared to isometric contractions, but consume greater amounts of energy as shortening velocity increases. Conversely, more force is generated and less energy is consumed during eccentric muscle contractions (lengthening). This relationship between force, energy use, and the velocity of contraction has important implications for understanding muscle efficiency, but the molecular mechanisms underlying this behavior remain poorly understood. Here we used spatially-explicit, multi-filament models of Ca2+-regulated force production within a half-sarcomere to simulate how force production, energy utilization, and the number of bound cross-bridges are affected by dynamic changes in sarcomere length. These computational simulations show that cross-bridge binding increased during slow-velocity concentric and eccentric contractions, compared to isometric contractions. Over the full ranges of velocities that we simulated, cross-bridge cycling and energy utilization (i.e. ATPase rates) increased during shortening, and decreased during lengthening. These findings are consistent with the Fenn effect, but arise from a complicated relationship between velocity-dependent cross-bridge recruitment and cross-bridge cycling kinetics. We also investigated how force production, power output, and energy utilization varied with cross-bridge and myofilament compliance, which is impossible to address under typical experimental conditions. These important simulations show that increasing cross-bridge compliance resulted in greater cross-bridge binding and ATPase activity, but less force was generated per cross-bridge and throughout the sarcomere. These data indicate that the efficiency of force production decreases in a velocity-dependent manner, and that this behavior is sensitive to cross-bridge compliance. In contrast, significant effects of myofilament compliance on force production were only observed during isometric contractions, suggesting that changes in myofilament compliance may not influence power output during non-isometric contractions as greatly as changes in cross-bridge compliance. These findings advance our understanding of how cross-bridge and myofilament properties underlie velocity-dependent changes in contractile efficiency during muscle movement.
7 CFR 1436.5 - Eligible borrowers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... erodible land and wetlands conservation provisions according to 7 CFR part 12; (8) Demonstrates compliance with any applicable local zoning, land use, and building codes for the applicable farm storage facility...
Technical Basis for PNNL Beryllium Inventory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Michelle Lynn
2014-07-09
The Department of Energy (DOE) issued Title 10 of the Code of Federal Regulations Part 850, “Chronic Beryllium Disease Prevention Program” (the Beryllium Rule) in 1999 and required full compliance by no later than January 7, 2002. The Beryllium Rule requires the development of a baseline beryllium inventory of the locations of beryllium operations and other locations of potential beryllium contamination at DOE facilities. The baseline beryllium inventory is also required to identify workers exposed or potentially exposed to beryllium at those locations. Prior to DOE issuing 10 CFR 850, Pacific Northwest Nuclear Laboratory (PNNL) had documented the beryllium characterizationmore » and worker exposure potential for multiple facilities in compliance with DOE’s 1997 Notice 440.1, “Interim Chronic Beryllium Disease.” After DOE’s issuance of 10 CFR 850, PNNL developed an implementation plan to be compliant by 2002. In 2014, an internal self-assessment (ITS #E-00748) of PNNL’s Chronic Beryllium Disease Prevention Program (CBDPP) identified several deficiencies. One deficiency is that the technical basis for establishing the baseline beryllium inventory when the Beryllium Rule was implemented was either not documented or not retrievable. In addition, the beryllium inventory itself had not been adequately documented and maintained since PNNL established its own CBDPP, separate from Hanford Site’s program. This document reconstructs PNNL’s baseline beryllium inventory as it would have existed when it achieved compliance with the Beryllium Rule in 2001 and provides the technical basis for the baseline beryllium inventory.« less
Jobse, I; Liao, Y; Bartram, M; Delantonio, K; Uter, W; Stehle, P; Sieber, C C; Volkert, D
2015-03-01
Administration of oral nutritional supplements (ONS) is an effective strategy to treat and avoid malnutrition, a persisting issue in nursing homes. However, little is known about compliance in the NH population. This study aimed to analyse the effects of compliance of NH residents with a low-volume, nutrient- and energy-dense ONS on nutritional status and to identify residents' characteristics associated with compliance. Randomized, controlled trial in nursing homes. 87 nursing home residents (87 ± 6y, 91% female) with malnutrition or at risk of malnutrition were randomly allocated to an intervention group (IG) receiving 2 x 125 ml ONS (2.4 kcal/ml)/d for 12 weeks, or the control group (CG) with usual care. ONS intake was recorded daily and compliance calculated. Low and high compliance were defined as ≤ 30% and ≥ 80% of provided ONS actually consumed, respectively. Body weight (BW), BMI, upper-arm (UAC) and calf-circumference (CC) and MNA-SF were assessed at baseline and after 12 weeks. Associations between compliance and changes of nutritional parameters and residents' characteristics were analysed. Compliance was high in 35.7% and low in 28.6% of the IG (n=42). BW change was significantly higher in subjects with high compliance (median +3.0 (interquartile range +2.1;+3.8) kg, n=15) than in those with low compliance (-0.2 (-2.2;+1.6) kg, n=12) and CG (-0.1 (-1.2; +0.6) kg, n=35; p<0.001), and significantly correlated with compliance in IG (r=0.691; p<0.001). Significant differences and correlations were also identified for BMI, UAC and MNA-SF. High compliance was more often observed in residents with malnutrition (66.7 vs. 27.3%) and chewing difficulties (77.8 vs. 24.2%) than in those without these conditions. Low compliance was more prevalent in residents who were immobile (45.0 vs. 13.6%), depressed (33.3 vs. 6.7%) or had gastrointestinal complaints (50.0 vs. 17.9%) (all p<0.05). A high compliance of nursing home residents with a low volume, nutrient- and energy dense ONS was related to a significantly improved nutritional status in comparison to low compliance and therefore enhanced the effectiveness of ONS. A higher compliance may be achieved by consideration of different residents' characteristics.
Klein, Kimberly
2010-01-01
The American Recovery and Reinvestment Act of 2009 (ARRA) has set forth legislation for the healthcare community to achieve adoption of electronic health records (EHR), as well as form data standards, health information exchanges (HIE) and compliance with more stringent security and privacy controls under the HITECH Act. While the Office of the National Coordinator for Health Information Technology (ONCHIT) works on the definition of both "meaningful use" and "certification" of information technology systems, providers in particular must move forward with their IT initiatives to achieve the basic requirements for Medicare and Medicaid incentives starting in 2011, and avoid penalties that will reduce reimbursement beginning in 2015. In addition, providers, payors, government and non-government stakeholders will all have to balance the implementation of EHRs, working with HIEs, at the same time that they must upgrade their systems to be in compliance with ICD-10 and HIPAA 5010 code sets. Compliance deadlines for EHRs and HIEs begin in 2011, while ICD-10 diagnosis and procedure code sets compliance is required by October 2013 and HIPAA 5010 transaction sets, with one exception, is required by January 1, 2012. In order to accomplish these strategic and mandatory initiatives successfully and simultaneously, healthcare organizations will require significant and thoughtful planning, prioritization and execution.
Health and nutrition content claims on Australian fast-food websites.
Wellard, Lyndal; Koukoumas, Alexandra; Watson, Wendy L; Hughes, Clare
2017-03-01
To determine the extent that Australian fast-food websites contain nutrition content and health claims, and whether these claims are compliant with the new provisions of the Australia New Zealand Food Standards Code ('the Code'). Systematic content analysis of all web pages to identify nutrition content and health claims. Nutrition information panels were used to determine whether products with claims met Nutrient Profiling Scoring Criteria (NPSC) and qualifying criteria, and to compare them with the Code to determine compliance. Australian websites of forty-four fast-food chains including meals, bakery, ice cream, beverage and salad chains. Any products marketed on the websites using health or nutrition content claims. Of the forty-four fast-food websites, twenty (45 %) had at least one claim. A total of 2094 claims were identified on 371 products, including 1515 nutrition content (72 %) and 579 health claims (28 %). Five fast-food products with health (5 %) and 157 products with nutrition content claims (43 %) did not meet the requirements of the Code to allow them to carry such claims. New provisions in the Code came into effect in January 2016 after a 3-year transition. Food regulatory agencies should review fast-food websites to ensure compliance with the qualifying criteria for nutrition content and health claim regulations. This would prevent consumers from viewing unhealthy foods as healthier choices. Healthy choices could be facilitated by applying NPSC to nutrition content claims. Fast-food chains should be educated on the requirements of the Code regarding claims.
10 CFR 1040.101 - Compliance reviews.
Code of Federal Regulations, 2011 CFR
2011-01-01
... DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION IN FEDERALLY ASSISTED PROGRAMS OR ACTIVITIES Program Monitoring § 1040.101 Compliance reviews. (a) The Director shall periodically conduct compliance... of: (1) The practices to be reviewed; (2) The programs or activities affected by the review; (3) The...
10 CFR 1040.101 - Compliance reviews.
Code of Federal Regulations, 2013 CFR
2013-01-01
... DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION IN FEDERALLY ASSISTED PROGRAMS OR ACTIVITIES Program Monitoring § 1040.101 Compliance reviews. (a) The Director shall periodically conduct compliance... of: (1) The practices to be reviewed; (2) The programs or activities affected by the review; (3) The...
10 CFR 1040.101 - Compliance reviews.
Code of Federal Regulations, 2012 CFR
2012-01-01
... DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION IN FEDERALLY ASSISTED PROGRAMS OR ACTIVITIES Program Monitoring § 1040.101 Compliance reviews. (a) The Director shall periodically conduct compliance... of: (1) The practices to be reviewed; (2) The programs or activities affected by the review; (3) The...
10 CFR 1040.101 - Compliance reviews.
Code of Federal Regulations, 2014 CFR
2014-01-01
... DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION IN FEDERALLY ASSISTED PROGRAMS OR ACTIVITIES Program Monitoring § 1040.101 Compliance reviews. (a) The Director shall periodically conduct compliance... of: (1) The practices to be reviewed; (2) The programs or activities affected by the review; (3) The...
10 CFR 1040.101 - Compliance reviews.
Code of Federal Regulations, 2010 CFR
2010-01-01
... DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION IN FEDERALLY ASSISTED PROGRAMS OR ACTIVITIES Program Monitoring § 1040.101 Compliance reviews. (a) The Director shall periodically conduct compliance... of: (1) The practices to be reviewed; (2) The programs or activities affected by the review; (3) The...
18 CFR 284.11 - Environmental compliance.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Environmental compliance. 284.11 Section 284.11 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... RELATED AUTHORITIES General Provisions and Conditions § 284.11 Environmental compliance. (a) Any activity...
18 CFR 284.11 - Environmental compliance.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Environmental compliance. 284.11 Section 284.11 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... RELATED AUTHORITIES General Provisions and Conditions § 284.11 Environmental compliance. (a) Any activity...
76 FR 66713 - Atlanta Gas Light Company; Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-27
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-108-003] Atlanta Gas Light Company; Notice of Compliance Filing Take notice that on October 19, 2011, Atlanta Gas Light Company filed a revised Statement of Operating Conditions to incorporate three modifications to comply...
77 FR 46432 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-03
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice... Reform III Compliance Filing to be effective 1/1/2012. Filed Date: 7/25/12. Accession Number: 20120725... Power Canada Ltd. Description: ATCO Compliance Filing of Revised Tariff and Request for Category 1 to be...
10 CFR 72.246 - Issuance of amendment to a certificate of compliance.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Issuance of amendment to a certificate of compliance. 72.246 Section 72.246 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN...
10 CFR 72.244 - Application for amendment of a certificate of compliance.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Application for amendment of a certificate of compliance. 72.244 Section 72.244 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN...
10 CFR 72.238 - Issuance of an NRC Certificate of Compliance.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Issuance of an NRC Certificate of Compliance. 72.238 Section 72.238 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...
76 FR 6607 - Combined Notice of Filings No. 2
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-07
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings No. 2 January...--Baseline Compliance All Volumes to be effective 5/28/ 2010. Filed Date: 01/24/2011. Accession Number... 154.203: DTI--Baseline Compliance Subsequent Filing 1 to be effective 7/1/2010. Filed Date: 01/24/2011...
NASA Astrophysics Data System (ADS)
DuBrey, Stephen
Due to federal mandates, there is an increasing demand to advance renewable energy in the District of Columbia (D.C.) to deliver power. Utilities must find ways to achieve objectives while avoiding costly alternative compliance payments. In 2016, the District of Columbia's Renewable Portfolio Standard (RPS) Expansion Act made significant amendments expanding renewable energy source requirements to 50% by 2032 and solar requirements to 5% by 2032, while current utility renewable energy percentages are at 4% and solar is at ˜0.1%. With the RPS mandate, utilities will need to improve and enhance facilitation of the interconnection of renewable energy within the power delivery system. This study will focus on the evaluation and implementation of various renewable energy systems in the District of Columbia. The main objective is to analyze the best feasible options available to meet RPS targets. If electricity suppliers are unable to meet requirements, suppliers must pay both renewable energy credits (RECs) and alternative compliance fees (ACFs) and the financial burden of compliance will ultimately be passed on to customers of the electricity suppliers. This study will also review and present the cost-effective means of REC's can be used for RPS compliance and results will provide policymakers a better understanding of how to address renewable energy requirements locally in the District.
14 CFR 257.6 - Effective and compliance dates.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the selling carrier is not the transporting carrier and (ii) Of the transporting carrier's identity... transportation involving a code-share arrangement of the transporting carrier's corporate name and any other name...
14 CFR 257.6 - Effective and compliance dates.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the selling carrier is not the transporting carrier and (ii) Of the transporting carrier's identity... transportation involving a code-share arrangement of the transporting carrier's corporate name and any other name...
14 CFR 257.6 - Effective and compliance dates.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the selling carrier is not the transporting carrier and (ii) Of the transporting carrier's identity... transportation involving a code-share arrangement of the transporting carrier's corporate name and any other name...
14 CFR 257.6 - Effective and compliance dates.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the selling carrier is not the transporting carrier and (ii) Of the transporting carrier's identity... transportation involving a code-share arrangement of the transporting carrier's corporate name and any other name...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stovall, Therese K; Biswas, Kaushik; Song, Bo
In November of 2009, the presidents of China and the U.S. announced the establishment of the Clean Energy Research Center (CERC). This broad research effort is co-funded by both countries and involves a large number of research centers and universities in both countries. One part of this program is focused on improving the energy efficiency of buildings. One portion of the CERC-BEE was focused on building insulation systems. The research objective of this effort was to Identify and investigate candidate high performance fire resistant building insulation technologies that meet the goal of building code compliance for exterior wall applications inmore » green buildings in multiple climate zones. A Joint Work Plan was established between researchers at the China Academy of Building Research and Oak Ridge National Laboratory. Efforts in the first year under this plan focused on information gathering. The objective of this research program is to reduce building energy use in China via improved building insulation technology. In cold regions in China, residents often use inefficient heating systems to provide a minimal comfort level within inefficient buildings. In warmer regions, air conditioning has not been commonly used. As living standards rise, energy consumption in these regions will increase dramatically unless significant improvements are made in building energy performance. Previous efforts that defined the current state of the built environment in China and in the U.S. will be used in this research. In countries around the world, building improvements have typically followed the implementation of more stringent building codes. There have been several changes in building codes in both the U.S. and China within the last few years. New U.S. building codes have increased the amount of wall insulation required in new buildings. New government statements from multiple agencies in China have recently changed the requirements for buildings in terms of energy efficiency and fire safety. A related issue is the degree to which new standards are adopted and enforced. In the U.S., standards are developed using a consensus process, and local government agencies are free to implement these standards or to ignore them. For example, some U.S. states are still using 2003 versions of the building efficiency standards. There is also a great variation in the degree to which the locally adopted standards are enforced in different U.S. cities and states. With a more central process in China, these issues are different, but possible impacts of variable enforcement efficacy may also exist. Therefore, current building codes in China will be compared to the current state of building fire-safety and energy-efficiency codes in the U.S. and areas for possible improvements in both countries will be explored. In particular, the focus of the applications in China will be on green buildings. The terminology of 'green buildings' has different meanings to different audiences. The U.S. research is interested in both new, green buildings, and on retrofitting existing inefficient buildings. An initial effort will be made to clarify the scope of the pertinent wall insulation systems for these applications.« less
Architectural Coatings: National Volatile Organic Compounds Emission Standards
Read about the section 183(e) rule for volatile organic compounds for architectural coatings. Read the rule summary and history, find the code of federal regulations test, and additional documents, including compliance information.
Implementing Nepal's national building code—A case study in patience and persistence
Arendt, Lucy; Hortacsu, Ayse; Jaiswal, Kishor; Bevington, John; Shrestha, Surya; Lanning, Forrest; Mentor-William, Garmalia; Naeem, Ghazala; Thibert, Kate
2017-01-01
The April 2015 Gorkha Nepal earthquake revealed the relative effectiveness of the Nepal Standard, or national building code (NBC), and irregular compliance with it in different parts of Nepal. Much of the damage to more than half a million Nepal's residential structures may be attributed to the prevalence of owner-built or owner-supervised construction and the lack of owner and builder responsiveness to seismic risk and training in the appropriate means of complying with the NBC. To explain these circumstances, we review the protracted implementation of the NBC and the role played by one organization, the National Society for Earthquake Technology-Nepal (NSET), in the NBC's implementation. We also share observations on building code compliance made by individuals in Nepal participating in workshops led by the Earthquake Engineering Research Institute's 2014 class of Housner Fellows.
Limits of Brazil's Forest Code as a means to end illegal deforestation.
Azevedo, Andrea A; Rajão, Raoni; Costa, Marcelo A; Stabile, Marcelo C C; Macedo, Marcia N; Dos Reis, Tiago N P; Alencar, Ane; Soares-Filho, Britaldo S; Pacheco, Rayane
2017-07-18
The 2012 Brazilian Forest Code governs the fate of forests and savannas on Brazil's 394 Mha of privately owned lands. The government claims that a new national land registry (SICAR), introduced under the revised law, could end illegal deforestation by greatly reducing the cost of monitoring, enforcement, and compliance. This study evaluates that potential, using data from state-level land registries (CAR) in Pará and Mato Grosso that were precursors of SICAR. Using geospatial analyses and stakeholder interviews, we quantify the impact of CAR on deforestation and forest restoration, investigating how landowners adjust their behaviors over time. Our results indicate rapid adoption of CAR, with registered properties covering a total of 57 Mha by 2013. This suggests that the financial incentives to join CAR currently exceed the costs. Registered properties initially showed lower deforestation rates than unregistered ones, but these differences varied by property size and diminished over time. Moreover, only 6% of registered producers reported taking steps to restore illegally cleared areas on their properties. Our results suggest that, from the landowner's perspective, full compliance with the Forest Code offers few economic benefits. Achieving zero illegal deforestation in this context would require the private sector to include full compliance as a market criterion, while state and federal governments develop SICAR as a de facto enforcement mechanism. These results are relevant to other tropical countries and underscore the importance of developing a policy mix that creates lasting incentives for sustainable land-use practices.
Limits of Brazil’s Forest Code as a means to end illegal deforestation
Azevedo, Andrea A.; Rajão, Raoni; Costa, Marcelo A.; Stabile, Marcelo C. C.; dos Reis, Tiago N. P.; Alencar, Ane; Soares-Filho, Britaldo S.; Pacheco, Rayane
2017-01-01
The 2012 Brazilian Forest Code governs the fate of forests and savannas on Brazil’s 394 Mha of privately owned lands. The government claims that a new national land registry (SICAR), introduced under the revised law, could end illegal deforestation by greatly reducing the cost of monitoring, enforcement, and compliance. This study evaluates that potential, using data from state-level land registries (CAR) in Pará and Mato Grosso that were precursors of SICAR. Using geospatial analyses and stakeholder interviews, we quantify the impact of CAR on deforestation and forest restoration, investigating how landowners adjust their behaviors over time. Our results indicate rapid adoption of CAR, with registered properties covering a total of 57 Mha by 2013. This suggests that the financial incentives to join CAR currently exceed the costs. Registered properties initially showed lower deforestation rates than unregistered ones, but these differences varied by property size and diminished over time. Moreover, only 6% of registered producers reported taking steps to restore illegally cleared areas on their properties. Our results suggest that, from the landowner's perspective, full compliance with the Forest Code offers few economic benefits. Achieving zero illegal deforestation in this context would require the private sector to include full compliance as a market criterion, while state and federal governments develop SICAR as a de facto enforcement mechanism. These results are relevant to other tropical countries and underscore the importance of developing a policy mix that creates lasting incentives for sustainable land-use practices. PMID:28674015
Status and Trends in U.S. Compliance and Voluntary Renewable Energy Certificate Markets (2010 Data)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heeter, J.; Bird, L.
2011-10-01
This report documents the status and trends of 'compliance'--renewable energy certificate (REC) markets used to meet state renewable portfolio standard (RPS) requirements--and 'voluntary' markets--those in which consumers and institutions purchase renewable energy to match their electricity needs on a voluntary basis. Today, 29 states and the District of Columbia have an RPS, more than half of all U.S. electricity customers have an option to purchase some type of green power product directly from a retail electricity provider, and all consumers have the option to purchase RECs. This report documents REC activities and trends in the United States. The compliance RECmore » market analysis includes analysis of REC trading, regional REC markets, REC tracking systems, types of compliance RECs, compliance REC pricing trends, and an overview of compliance with RPS polices. The voluntary REC analysis presents data and analysis on voluntary market sales and customer participation, products and premiums, green pricing marketing and administrative expenses, voluntary REC pricing, and the voluntary carbon offsets market. The report concludes with a discussion of upcoming guidance from the Federal Trade Commission on green marketing claims, the emergence of community solar programs, and the potential impact of Dodd-Frank regulations on the REC market.« less
Alternative approach for fire suppression of class A, B and C fires in gloveboxes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberger, Mark S; Tsiagkouris, James A
2011-02-10
Department of Energy (DOE) Orders and National Fire Protection Association (NFPA) Codes and Standards require fire suppression in gloveboxes. Several potential solutions have been and are currently being considered at Los Alamos National Laboratory (LANL). The objective is to provide reliable, minimally invasive, and seismically robust fire suppression capable of extinguishing Class A, B, and C fires; achieve compliance with DOE and NFPA requirements; and provide value-added improvements to fire safety in gloveboxes. This report provides a brief summary of current approaches and also documents the successful fire tests conducted to prove that one approach, specifically Fire Foe{trademark} tubes, ismore » capable of achieving the requirement to provide reliable fire protection in gloveboxes in a cost-effective manner.« less
75 FR 28602 - Corning Natural Gas Corporation; Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-21
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR09-30-003] Corning Natural Gas Corporation; Notice of Compliance Filing May 17, 2010. Take notice that on May 10, 2010, Corning Natural Gas Corporation, (Corning) filed a corrected rate sheet to replace the rate sheet filed with its...
75 FR 9201 - DCP Raptor Pipeline, LLC; Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-01
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR09-32-002] DCP Raptor... Raptor Pipeline, LLC (Raptor) filed its Statement of Operating Conditions in compliance with the January 27, 2010 Letter Order (January 27th Letter Order) in Docket Nos. PR09-32-000 and PR09-32-001. Raptor...
75 FR 66077 - Bay Gas Storage Company Ltd.; Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-27
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-15-002] Bay Gas Storage Company Ltd.; Notice of Compliance Filing October 20, 2010. Take notice that on October 13, 2010, Bay Gas Storage Company Ltd. (Bay Gas) filed its Refund Report pursuant to its August 30, 2010 Settlement...
77 FR 66829 - Notice of Compliance Filings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-07
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [ Docket Nos. ER13-187-000; ER13-187-001, et al.] Notice of Compliance Filings Docket Nos. Midwest Independent Transmission System ER13-187-000 Docket No. ER13- Operator, Inc. 187-001. ISO New England Inc ER13-193-000. PJM Transmission Owners ER13...
CH-TRU Waste Content Codes (CH-TRUCON)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington TRU Solutions LLC
2007-08-15
The CH-TRU Waste Content Codes (CH-TRUCON) document describes the inventory of the U.S. Department of Energy (DOE) CH-TRU waste within the transportation parameters specified by the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC). The CH-TRAMPAC defines the allowable payload for the Transuranic Package Transporter-II (TRUPACT-II) and HalfPACT packagings. This document is a catalog of TRUPACT-II and HalfPACT authorized contents and a description of the methods utilized to demonstrate compliance with the CH-TRAMPAC. A summary of currently approved content codes by site is presented in Table 1. The CH-TRAMPAC describes "shipping categories" that are assigned to each payload container.more » Multiple shipping categories may be assigned to a single content code. A summary of approved content codes and corresponding shipping categories is provided in Table 2, which consists of Tables 2A, 2B, and 2C. Table 2A provides a summary of approved content codes and corresponding shipping categories for the "General Case," which reflects the assumption of a 60-day shipping period as described in the CH-TRAMPAC and Appendix 3.4 of the CH-TRU Payload Appendices. For shipments to be completed within an approximately 1,000-mile radius, a shorter shipping period of 20 days is applicable as described in the CH-TRAMPAC and Appendix 3.5 of the CH-TRU Payload Appendices. For shipments to WIPP from Los Alamos National Laboratory (LANL), Nevada Test Site, and Rocky Flats Environmental Technology Site, a 20-day shipping period is applicable. Table 2B provides a summary of approved content codes and corresponding shipping categories for "Close-Proximity Shipments" (20-day shipping period). For shipments implementing the controls specified in the CH-TRAMPAC and Appendix 3.6 of the CH-TRU Payload Appendices, a 10-day shipping period is applicable. Table 2C provides a summary of approved content codes and corresponding shipping categories for "Controlled Shipments" (10-day shipping period).« less
CH-TRU Waste Content Codes (CH-TRUCON)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington TRU Solutions LLC
2007-06-15
The CH-TRU Waste Content Codes (CH-TRUCON) document describes the inventory of the U.S. Department of Energy (DOE) CH-TRU waste within the transportation parameters specified by the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC). The CH-TRAMPAC defines the allowable payload for the Transuranic Package Transporter-II (TRUPACT-II) and HalfPACT packagings. This document is a catalog of TRUPACT-II and HalfPACT authorized contents and a description of the methods utilized to demonstrate compliance with the CH-TRAMPAC. A summary of currently approved content codes by site is presented in Table 1. The CH-TRAMPAC describes "shipping categories" that are assigned to each payload container.more » Multiple shipping categories may be assigned to a single content code. A summary of approved content codes and corresponding shipping categories is provided in Table 2, which consists of Tables 2A, 2B, and 2C. Table 2A provides a summary of approved content codes and corresponding shipping categories for the "General Case," which reflects the assumption of a 60-day shipping period as described in the CH-TRAMPAC and Appendix 3.4 of the CH-TRU Payload Appendices. For shipments to be completed within an approximately 1,000-mile radius, a shorter shipping period of 20 days is applicable as described in the CH-TRAMPAC and Appendix 3.5 of the CH-TRU Payload Appendices. For shipments to WIPP from Los Alamos National Laboratory (LANL), Nevada Test Site, and Rocky Flats Environmental Technology Site, a 20-day shipping period is applicable. Table 2B provides a summary of approved content codes and corresponding shipping categories for "Close-Proximity Shipments" (20-day shipping period). For shipments implementing the controls specified in the CH-TRAMPAC and Appendix 3.6 of the CH-TRU Payload Appendices, a 10-day shipping period is applicable. Table 2C provides a summary of approved content codes and corresponding shipping categories for "Controlled Shipments" (10-day shipping period).« less
CH-TRU Waste Content Codes (CH-TRUCON)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington TRU Solutions LLC
2007-09-20
The CH-TRU Waste Content Codes (CH-TRUCON) document describes the inventory of the U.S. Department of Energy (DOE) CH-TRU waste within the transportation parameters specified by the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC). The CH-TRAMPAC defines the allowable payload for the Transuranic Package Transporter-II (TRUPACT-II) and HalfPACT packagings. This document is a catalog of TRUPACT-II and HalfPACT authorized contents and a description of the methods utilized to demonstrate compliance with the CH-TRAMPAC. A summary of currently approved content codes by site is presented in Table 1. The CH-TRAMPAC describes "shipping categories" that are assigned to each payload container.more » Multiple shipping categories may be assigned to a single content code. A summary of approved content codes and corresponding shipping categories is provided in Table 2, which consists of Tables 2A, 2B, and 2C. Table 2A provides a summary of approved content codes and corresponding shipping categories for the "General Case," which reflects the assumption of a 60-day shipping period as described in the CH-TRAMPAC and Appendix 3.4 of the CH-TRU Payload Appendices. For shipments to be completed within an approximately 1,000-mile radius, a shorter shipping period of 20 days is applicable as described in the CH-TRAMPAC and Appendix 3.5 of the CH-TRU Payload Appendices. For shipments to WIPP from Los Alamos National Laboratory (LANL), Nevada Test Site, and Rocky Flats Environmental Technology Site, a 20-day shipping period is applicable. Table 2B provides a summary of approved content codes and corresponding shipping categories for "Close-Proximity Shipments" (20-day shipping period). For shipments implementing the controls specified in the CH-TRAMPAC and Appendix 3.6 of the CH-TRU Payload Appendices, a 10-day shipping period is applicable. Table 2C provides a summary of approved content codes and corresponding shipping categories for "Controlled Shipments" (10-day shipping period).« less
CH-TRU Waste Content Codes (CH-TRUCON)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington TRU Solutions LLC
2006-06-20
The CH-TRU Waste Content Codes (CH-TRUCON) document describes the inventory of the U.S. Department of Energy (DOE) CH-TRU waste within the transportation parameters specified by the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC). The CH-TRAMPAC defines the allowable payload for the Transuranic Package Transporter-II (TRUPACT-II) and HalfPACT packagings. This document is a catalog of TRUPACT-II and HalfPACT authorized contents and a description of the methods utilized to demonstrate compliance with the CH-TRAMPAC. A summary of currently approved content codes by site is presented in Table 1. The CH-TRAMPAC describes "shipping categories" that are assigned to each payload container.more » Multiple shipping categories may be assigned to a single content code. A summary of approved content codes and corresponding shipping categories is provided in Table 2, which consists of Tables 2A, 2B, and 2C. Table 2A provides a summary of approved content codes and corresponding shipping categories for the "General Case," which reflects the assumption of a 60-day shipping period as described in the CH-TRAMPAC and Appendix 3.4 of the CH-TRU Payload Appendices. For shipments to be completed within an approximately 1,000-mile radius, a shorter shipping period of 20 days is applicable as described in the CH-TRAMPAC and Appendix 3.5 of the CH-TRU Payload Appendices. For shipments to WIPP from Los Alamos National Laboratory (LANL), Nevada Test Site, and Rocky Flats Environmental Technology Site, a 20-day shipping period is applicable. Table 2B provides a summary of approved content codes and corresponding shipping categories for "Close-Proximity Shipments" (20-day shipping period). For shipments implementing the controls specified in the CH-TRAMPAC and Appendix 3.6 of the CH-TRU Payload Appendices, a 10-day shipping period is applicable. Table 2C provides a summary of approved content codes and corresponding shipping categories for "Controlled Shipments" (10-day shipping period).« less
CH-TRU Waste Content Codes (CH-TRUCON)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington TRU Solutions LLC
2006-01-18
The CH-TRU Waste Content Codes (CH-TRUCON) document describes the inventory of the U.S. Department of Energy (DOE) CH-TRU waste within the transportation parameters specified by the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC). The CH-TRAMPAC defines the allowable payload for the Transuranic Package Transporter-II (TRUPACT-II) and HalfPACT packagings. This document is a catalog of TRUPACT-II and HalfPACT authorized contents and a description of the methods utilized to demonstrate compliance with the CH-TRAMPAC. A summary of currently approved content codes by site is presented in Table 1. The CH-TRAMPAC describes "shipping categories" that are assigned to each payload container.more » Multiple shipping categories may be assigned to a single content code. A summary of approved content codes and corresponding shipping categories is provided in Table 2, which consists of Tables 2A, 2B, and 2C. Table 2A provides a summary of approved content codes and corresponding shipping categories for the "General Case," which reflects the assumption of a 60-day shipping period as described in the CH-TRAMPAC and Appendix 3.4 of the CH-TRU Payload Appendices. For shipments to be completed within an approximately 1,000-mile radius, a shorter shipping period of 20 days is applicable as described in the CH-TRAMPAC and Appendix 3.5 of the CH-TRU Payload Appendices. For shipments to WIPP from Los Alamos National Laboratory (LANL), Nevada Test Site, and Rocky Flats Environmental Technology Site, a 20-day shipping period is applicable. Table 2B provides a summary of approved content codes and corresponding shipping categories for "Close-Proximity Shipments" (20-day shipping period). For shipments implementing the controls specified in the CH-TRAMPAC and Appendix 3.6 of the CH-TRU Payload Appendices, a 10-day shipping period is applicable. Table 2C provides a summary of approved content codes and corresponding shipping categories for "Controlled Shipments" (10-day shipping period).« less
CH-TRU Waste Content Codes (CH-TRUCON)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington TRU Solutions LLC
2006-08-15
The CH-TRU Waste Content Codes (CH-TRUCON) document describes the inventory of the U.S. Department of Energy (DOE) CH-TRU waste within the transportation parameters specified by the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC). The CH-TRAMPAC defines the allowable payload for the Transuranic Package Transporter-II (TRUPACT-II) and HalfPACT packagings. This document is a catalog of TRUPACT-II and HalfPACT authorized contents and a description of the methods utilized to demonstrate compliance with the CH-TRAMPAC. A summary of currently approved content codes by site is presented in Table 1. The CH-TRAMPAC describes "shipping categories" that are assigned to each payload container.more » Multiple shipping categories may be assigned to a single content code. A summary of approved content codes and corresponding shipping categories is provided in Table 2, which consists of Tables 2A, 2B, and 2C. Table 2A provides a summary of approved content codes and corresponding shipping categories for the "General Case," which reflects the assumption of a 60-day shipping period as described in the CH-TRAMPAC and Appendix 3.4 of the CH-TRU Payload Appendices. For shipments to be completed within an approximately 1,000-mile radius, a shorter shipping period of 20 days is applicable as described in the CH-TRAMPAC and Appendix 3.5 of the CH-TRU Payload Appendices. For shipments to WIPP from Los Alamos National Laboratory (LANL), Nevada Test Site, and Rocky Flats Environmental Technology Site, a 20-day shipping period is applicable. Table 2B provides a summary of approved content codes and corresponding shipping categories for "Close-Proximity Shipments" (20-day shipping period). For shipments implementing the controls specified in the CH-TRAMPAC and Appendix 3.6 of the CH-TRU Payload Appendices, a 10-day shipping period is applicable. Table 2C provides a summary of approved content codes and corresponding shipping categories for "Controlled Shipments" (10-day shipping period).« less
CH-TRU Waste Content Codes (CH-TRUCON)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington TRU Solutions LLC
2006-12-20
The CH-TRU Waste Content Codes (CH-TRUCON) document describes the inventory of the U.S. Department of Energy (DOE) CH-TRU waste within the transportation parameters specified by the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC). The CH-TRAMPAC defines the allowable payload for the Transuranic Package Transporter-II (TRUPACT-II) and HalfPACT packagings. This document is a catalog of TRUPACT-II and HalfPACT authorized contents and a description of the methods utilized to demonstrate compliance with the CH-TRAMPAC. A summary of currently approved content codes by site is presented in Table 1. The CH-TRAMPAC describes "shipping categories" that are assigned to each payload container.more » Multiple shipping categories may be assigned to a single content code. A summary of approved content codes and corresponding shipping categories is provided in Table 2, which consists of Tables 2A, 2B, and 2C. Table 2A provides a summary of approved content codes and corresponding shipping categories for the "General Case," which reflects the assumption of a 60-day shipping period as described in the CH-TRAMPAC and Appendix 3.4 of the CH-TRU Payload Appendices. For shipments to be completed within an approximately 1,000-mile radius, a shorter shipping period of 20 days is applicable as described in the CH-TRAMPAC and Appendix 3.5 of the CH-TRU Payload Appendices. For shipments to WIPP from Los Alamos National Laboratory (LANL), Nevada Test Site, and Rocky Flats Environmental Technology Site, a 20-day shipping period is applicable. Table 2B provides a summary of approved content codes and corresponding shipping categories for "Close-Proximity Shipments" (20-day shipping period). For shipments implementing the controls specified in the CH-TRAMPAC and Appendix 3.6 of the CH-TRU Payload Appendices, a 10-day shipping period is applicable. Table 2C provides a summary of approved content codes and corresponding shipping categories for "Controlled Shipments" (10-day shipping period).« less
CH-TRU Waste Content Codes (CH-TRUCON)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington TRU Solutions LLC
2007-02-15
The CH-TRU Waste Content Codes (CH-TRUCON) document describes the inventory of the U.S. Department of Energy (DOE) CH-TRU waste within the transportation parameters specified by the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC). The CH-TRAMPAC defines the allowable payload for the Transuranic Package Transporter-II (TRUPACT-II) and HalfPACT packagings. This document is a catalog of TRUPACT-II and HalfPACT authorized contents and a description of the methods utilized to demonstrate compliance with the CH-TRAMPAC. A summary of currently approved content codes by site is presented in Table 1. The CH-TRAMPAC describes "shipping categories" that are assigned to each payload container.more » Multiple shipping categories may be assigned to a single content code. A summary of approved content codes and corresponding shipping categories is provided in Table 2, which consists of Tables 2A, 2B, and 2C. Table 2A provides a summary of approved content codes and corresponding shipping categories for the "General Case," which reflects the assumption of a 60-day shipping period as described in the CH-TRAMPAC and Appendix 3.4 of the CH-TRU Payload Appendices. For shipments to be completed within an approximately 1,000-mile radius, a shorter shipping period of 20 days is applicable as described in the CH-TRAMPAC and Appendix 3.5 of the CH-TRU Payload Appendices. For shipments to WIPP from Los Alamos National Laboratory (LANL), Nevada Test Site, and Rocky Flats Environmental Technology Site, a 20-day shipping period is applicable. Table 2B provides a summary of approved content codes and corresponding shipping categories for "Close-Proximity Shipments" (20-day shipping period). For shipments implementing the controls specified in the CH-TRAMPAC and Appendix 3.6 of the CH-TRU Payload Appendices, a 10-day shipping period is applicable. Table 2C provides a summary of approved content codes and corresponding shipping categories for "Controlled Shipments" (10-day shipping period).« less
CH-TRU Waste Content Codes (CH-TRUCON)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington TRU Solutions LLC
2006-09-15
The CH-TRU Waste Content Codes (CH-TRUCON) document describes the inventory of the U.S. Department of Energy (DOE) CH-TRU waste within the transportation parameters specified by the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC). The CH-TRAMPAC defines the allowable payload for the Transuranic Package Transporter-II (TRUPACT-II) and HalfPACT packagings. This document is a catalog of TRUPACT-II and HalfPACT authorized contents and a description of the methods utilized to demonstrate compliance with the CH-TRAMPAC. A summary of currently approved content codes by site is presented in Table 1. The CH-TRAMPAC describes "shipping categories" that are assigned to each payload container.more » Multiple shipping categories may be assigned to a single content code. A summary of approved content codes and corresponding shipping categories is provided in Table 2, which consists of Tables 2A, 2B, and 2C. Table 2A provides a summary of approved content codes and corresponding shipping categories for the "General Case," which reflects the assumption of a 60-day shipping period as described in the CH-TRAMPAC and Appendix 3.4 of the CH-TRU Payload Appendices. For shipments to be completed within an approximately 1,000-mile radius, a shorter shipping period of 20 days is applicable as described in the CH-TRAMPAC and Appendix 3.5 of the CH-TRU Payload Appendices. For shipments to WIPP from Los Alamos National Laboratory (LANL), Nevada Test Site, and Rocky Flats Environmental Technology Site, a 20-day shipping period is applicable. Table 2B provides a summary of approved content codes and corresponding shipping categories for "Close-Proximity Shipments" (20-day shipping period). For shipments implementing the controls specified in the CH-TRAMPAC and Appendix 3.6 of the CH-TRU Payload Appendices, a 10-day shipping period is applicable. Table 2C provides a summary of approved content codes and corresponding shipping categories for "Controlled Shipments" (10-day shipping period).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington TRU Solutions LLC
2008-01-16
The CH-TRU Waste Content Codes (CH-TRUCON) document describes the inventory of the U.S. Department of Energy (DOE) CH-TRU waste within the transportation parameters specified by the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC). The CH-TRAMPAC defines the allowable payload for the Transuranic Package Transporter-II (TRUPACT-II) and HalfPACT packagings. This document is a catalog of TRUPACT-II and HalfPACT authorized contents and a description of the methods utilized to demonstrate compliance with the CH-TRAMPAC. A summary of currently approved content codes by site is presented in Table 1. The CH-TRAMPAC describes "shipping categories" that are assigned to each payload container.more » Multiple shipping categories may be assigned to a single content code. A summary of approved content codes and corresponding shipping categories is provided in Table 2, which consists of Tables 2A, 2B, and 2C. Table 2A provides a summary of approved content codes and corresponding shipping categories for the "General Case," which reflects the assumption of a 60-day shipping period as described in the CH-TRAMPAC and Appendix 3.4 of the CH-TRU Payload Appendices. For shipments to be completed within an approximately 1,000-mile radius, a shorter shipping period of 20 days is applicable as described in the CH-TRAMPAC and Appendix 3.5 of the CH-TRU Payload Appendices. For shipments to WIPP from Los Alamos National Laboratory (LANL), Nevada Test Site, and Rocky Flats Environmental Technology Site, a 20-day shipping period is applicable. Table 2B provides a summary of approved content codes and corresponding shipping categories for "Close-Proximity Shipments" (20-day shipping period). For shipments implementing the controls specified in the CH-TRAMPAC and Appendix 3.6 of the CH-TRU Payload Appendices, a 10-day shipping period is applicable. Table 2C provides a summary of approved content codes and corresponding shipping categories for "Controlled Shipments" (10-day shipping period).« less
NAICS Sector 92: Public Administration
Find the public administration industries EPA regulations affect, with their North American Industry Classification System (NAICS) code. On those pages you can find a list of laws and regulations that affect your industry as well as compliance information
75 FR 22165 - Request for Certification of Compliance-Rural Industrialization Loan and Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-27
...-fit an existing manufacturing facility to produce autoclaved aerated concrete (AAC) ``green'' building materials. The NAICS industry code for this enterprise is: 327331 Concrete Block and Brick Manufacturing...
Environmental Factor(tm) system: RCRA hazardous waste handler information (on cd-rom). Database
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-04-01
Environmental Factor(tm) RCRA Hazardous Waste Handler Information on CD-ROM unleashes the invaluable information found in two key EPA data sources on hazardous waste handlers and offers cradle-to-grave waste tracking. It`s easy to search and display: (1) Permit status, design capacity and compliance history for facilities found in the EPA Resource Conservation and Recovery Information System (RCRIS) program tracking database; (2) Detailed information on hazardous wastes generation, management and minimization by companies who are large quantity generators, and (3) Data on the waste management practices of treatment, storage and disposal (TSD) facilities from the EPA Biennial Reporting System which is collectedmore » every other year. Environmental Factor`s powerful database retrieval system lets you: (1) Search for RCRA facilities by permit type, SIC code, waste codes, corrective action or violation information, TSD status, generator and transporter status and more; (2) View compliance information - dates of evaluation, violation, enforcement and corrective action; (3) Lookup facilities by waste processing categories of marketing, transporting, processing and energy recovery; (4) Use owner/operator information and names, titles and telephone numbers of project managers for prospecting; and (5) Browse detailed data on TSD facility and large quantity generators` activities such as onsite waste treatment, disposal, or recycling, offsite waste received, and waste generation and management. The product contains databases, search and retrieval software on two CD-ROMs, an installation diskette and User`s Guide. Environmental Factor has online context-sensitive help from any screen and a printed User`s Guide describing installation and step-by-step procedures for searching, retrieving and exporting. Hotline support is also available for no additional charge.« less
Environmental Factor{trademark} system: RCRA hazardous waste handler information
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-03-01
Environmental Factor{trademark} RCRA Hazardous Waste Handler Information on CD-ROM unleashes the invaluable information found in two key EPA data sources on hazardous waste handlers and offers cradle-to-grave waste tracking. It`s easy to search and display: (1) Permit status, design capacity and compliance history for facilities found in the EPA Resource Conservation and Recovery Information System (RCRIS) program tracking database; (2) Detailed information on hazardous wastes generation, management and minimization by companies who are large quantity generators, and (3) Data on the waste management practices of treatment, storage and disposal (TSD) facilities from the EPA Biennial Reporting System which is collectedmore » every other year. Environmental Factor`s powerful database retrieval system lets you: (1) Search for RCRA facilities by permit type, SIC code, waste codes, corrective action or violation information, TSD status, generator and transporter status and more; (2) View compliance information -- dates of evaluation, violation, enforcement and corrective action; (3) Lookup facilities by waste processing categories of marketing, transporting, processing and energy recovery; (4) Use owner/operator information and names, titles and telephone numbers of project managers for prospecting; and (5) Browse detailed data on TSD facility and large quantity generators` activities such as onsite waste treatment, disposal, or recycling, offsite waste received, and waste generation and management. The product contains databases, search and retrieval software on two CD-ROMs, an installation diskette and User`s Guide. Environmental Factor has online context-sensitive help from any screen and a printed User`s Guide describing installation and step-by-step procedures for searching, retrieving and exporting. Hotline support is also available for no additional charge.« less
Physical activity recommendations: an alternative approach using energy expenditure.
Mudd, Lanay M; Rafferty, Ann P; Reeves, Mathew J; Pivarnik, James M
2008-10-01
Most adults do not meet the American College of Sports Medicine and Centers for Disease Control and Prevention (ACSM/CDC) physical activity recommendations. Even fewer meet the more extreme Institute of Medicine (IOM) physical activity recommendations. Compliance with either recommendation has been conventionally assessed by combining frequencies and durations of self-reported activities. Leisure-time energy expenditure is a cumulative measure of activity that offers an alternative method of defining compliance. To calculate the leisure-time energy expenditure of adults complying with the ACSM/CDC or the IOM physical activity recommendations determined by conventional measures and to reexamine compliance with the IOM recommendation using energy expenditure criteria. National, cross-sectional data from the 2000 Behavioral Risk Factor Surveillance System determined the mode, frequency, and duration of up to two leisure-time activities performed by adults. Four mutually exclusive activity groups (Non-, Low-, ACSM/CDC-, and IOM-Active) were defined on the basis of frequencies and durations of reported activities. Leisure-time energy expenditure (kcal x kg(-1) x wk(-1)) was calculated per respondent. The energy expenditure threshold for meeting the IOM recommendation was calculated as 21 kcal x kg(-1) x wk(-1). Of the 162,669 respondents included in the analyses, 29.9% were Nonactive, whereas 42.3%, 23.3%, and 4.5% were Low-, ACSM/CDC-, and IOM-Active, respectively. Median leisure-time energy expenditure values were 9.0, 27.4, and 63.0 kcal x kg(-1) x wk(-1) for Low-, ACSM/CDC-, and IOM-Active groups, respectively. When using energy expenditure criteria, compliance with the IOM recommendation rose to 27.7% of respondents. Compliance with the IOM physical activity recommendation dramatically increased when assessed by energy expenditure compared with conventional criteria, thereby highlighting the potential bias of conventional methods. A significant proportion of adults meet the intent but not the letter of the IOM activity recommendation.
18 CFR 154.600 - Compliance with other subparts.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Compliance with other subparts. 154.600 Section 154.600 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... Changes § 154.600 Compliance with other subparts. Any proposal to implement a tariff change other than in...
18 CFR 154.600 - Compliance with other subparts.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Compliance with other subparts. 154.600 Section 154.600 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... Changes § 154.600 Compliance with other subparts. Any proposal to implement a tariff change other than in...
18 CFR 154.600 - Compliance with other subparts.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Compliance with other subparts. 154.600 Section 154.600 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... Changes § 154.600 Compliance with other subparts. Any proposal to implement a tariff change other than in...
18 CFR 154.600 - Compliance with other subparts.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Compliance with other subparts. 154.600 Section 154.600 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... Changes § 154.600 Compliance with other subparts. Any proposal to implement a tariff change other than in...
18 CFR 154.600 - Compliance with other subparts.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Compliance with other subparts. 154.600 Section 154.600 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... Changes § 154.600 Compliance with other subparts. Any proposal to implement a tariff change other than in...
Aguayo, Victor M; Ross, Jay S; Kanon, Souleyman; Ouedraogo, Andre N
2003-01-18
To monitor compliance with the International Code of Marketing of Breastmilk Substitutes in health systems, sales outlets, distribution points, and the news media in Togo and Burkina Faso, west Africa. Multisite cross sectional survey. Staff at 43 health facilities and 66 sales outlets and distribution points, 186 health providers, and 105 mothers of infants aged < or =5 months in 16 cities. Six (14%) health facilities had received donations of breast milk substitutes. All donations were being given to mothers free of charge. Health providers in five (12%) health facilities had received free samples of breast milk substitutes for purposes other than professional research or evaluation. Health professionals in five (12%) health facilities had received promotional gifts from manufacturers. Promotional materials of commercial breast milk substitutes were found in seven (16%) health facilities. Special displays to market commercial breast milk substitutes were found in 29 (44%) sales and distribution points. Forty commercial breast milk substitutes violated the labelling standards of the code: 21 were manufactured by Danone, 11 by Nestlé, and eight by other national and international manufacturers. Most (148, 90%) health providers had never heard of the code, and 66 mothers (63%) had never received any counselling on breast feeding by their health providers. In west Africa manufacturers are violating the code of marketing of breast milk substitutes. Comparable levels of code violations are observed with (Burkina Faso) or without (Togo) regulating legislation. Legislation must be accompanied by effective information, training, and monitoring systems to ensure that healthcare providers and manufacturers comply with evidence based practice and the code.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-24
... Energy and Non-Air Quality Environmental Impacts C. Comments on Factor Three--Existing Controls at FCPP D... compliance, (2) the energy and non-air quality environmental impacts of compliance, (3) any pollution control... installing and operating any of several equivalent controls on Units 1- 3, and through proper operation of...
75 FR 31429 - Bay Gas Storage Company, Ltd.; Notice of Compliance Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-03
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR08-17-002] Bay Gas Storage Company, Ltd.; Notice of Compliance Filing May 27, 2010. Take notice that on May 21, 2010, Bay Gas Storage Company, Ltd (Bay Gas) filed to comply with the April 15, 2010, Commission Order which directed Bay Gas to...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-19
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL10-61-002] Cargill Power Markets, LLC v. Public Service Company of New Mexico; Notice of Compliance Filing Take notice that on March 12, 2012, Public Service Company of New Mexico and Cargill Power Markets, LLC submitted a...
Environmental Compliance Issue Coordination
An order to establish the Department of Energy (DOE) requirements for coordination of significant environmental compliance issues to ensure timely development and consistent application of Departmental environmental policy and guidance
Support as a crucial predictor of good compliance of adolescents with a chronic disease.
Kyngas, H; Rissanen, M
2001-11-01
The purpose of this study was to describe the factors that predict compliance among adolescents with a chronic illness. The data were collected by questionnaires from adolescents with asthma, epilepsy, juvenile rheumatoid arthritis (JRA) and insulin-dependent diabetes mellitus (IDDM). Groups of 300 adolescents with these illnesses were selected from the Finnish Social Insurance Institution's register, giving a total study series of 1200 individuals. The final response percentage was 88% (n = 1061). The data were analysed with the SPSS software. Logistic regression was used to indicate the predictors of good compliance. The compliance of adolescents with a chronic disease was predicted on the basis of support from parents, nurses, physicians and friends, as well as motivation, energy and willpower. The most powerful predictor was support from nurses. The likelihood of adolescents supported by nurses complying with health regimens was 7.28-fold compared to the adolescents who did not receive support from nurses. The next powerful predictor was energy and willpower. Adolescents who had the energy and willpower to take care of themselves complied with health regimens with a 6.69-fold likelihood compared to the adolescents who did not have energy and willpower. Adolescents who had good motivation were 5.28 times more likely to comply than the adolescents who did not have motivation. Support from parents, physicians and friends similarly predicted good compliance with health regimens.
Country Report on Building Energy Codes in Australia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shui, Bin; Evans, Meredydd; Somasundaram, Sriram
2009-04-02
This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America (U.S.). This reports gives an overview of the development of building energy codes in Australia, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, and lighting) for commercial and residential buildings in Australia.
Grants Management Guidance for Non-Profit Organizations
This guidance is intended to provide non-profit grant recipients with information to ensure that their organizations remain in compliance with the Code of Federal Regulations (CFR), Office of Management (OMB) cost principles, and the terms and conditions.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-26
... (RFM) as follows: (a) By making pen and ink changes, insert into the Operating Limitations section... alternative methods of compliance. (d) The Joint Aircraft System/Component (JASC) Code is 7200: Engine...
77 FR 31892 - Request for Certification of Compliance-Rural Industrialization Loan and Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... skilled nursing facility and a 3,600 square foot maintenance building in Picayune, Mississippi. The NAICS industry code for this enterprise is: 623110 (nursing care facilities). DATES: All interested parties may...
Violations of the International Code of Marketing of Breast-milk Substitutes: Indonesia context.
Hidayana, Irma; Februhartanty, Judhiastuty; Parady, Vida A
2017-01-01
To measure compliance with the International Code of Marketing of Breast-milk Substitutes ('the Code') in Indonesia. The study was a cross-sectional survey using the Interagency Group on Breastfeeding Monitoring protocol. Public and private health facilities in six provinces on Java island in Indonesia. A total of 874 women (382 pregnant women and 492 breast-feeding mothers of infants below 6 months) and seventy-seven health workers were recruited from eighteen participating health facilities. The study also analysed a total of forty-four labels of breast-milk substitute products, twenty-seven television commercials for growing-up milk (for children >12 months) of nine brands and thirty-four print advertisements of fourteen brands. The study found that 20 % of the women had received advice and information on the use of breast-milk substitutes and 72 % had seen promotional materials for breast-milk substitutes. About 15 % reported receiving free samples and 16 % received gifts. Nearly a quarter of the health workers confirmed receiving visits from representatives of breast-milk substitute companies. Two health workers reported having received gifts from the companies. The most common labelling violations found were statements or visuals that discouraged breast-feeding and the absence of mention about the consideration of local climate in the expiration date. Violations of the Code by health workers, breast-milk substitute companies and their representatives were found in all provinces studied. A regular monitoring system should be in place to ensure improved compliance with and enforcement of the Code.
National Environmental Policy Act compliance guide. Volume II (reference book)
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1994-09-01
This document (Volume II of the National Environmental Policy Act Compliance Guide) contains current copies of regulations and guidance from the Council on Environmental Quality, the Department of Energy, the Department of State, and the Environmental Protection Agency, related to compliance with the National Environmental Policy Act of 1969 (NEPA).
Leadership for the 1970s. A Leadership Model for Organizational Ethics.
1978-11-01
orientation to the community’s interest, and to reflecting a high degree of self -discipline through adherence to a code of ethics. Compliance with these...that reflects self -sacrifice and complete dedication, and (4" a steadfast responsibility to a code of ethical conduct. Trarjitonaliy, the clergy...social values. Not only does society have an obligation to reflect changing social values but it also has a responsibility to attempt to shape
Data Sciences Summer Institute Topology Optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watts, Seth
DSSI_TOPOPT is a 2D topology optimization code that designs stiff structures made of a single linear elastic material and void space. The code generates a finite element mesh of a rectangular design domain on which the user specifies displacement and load boundary conditions. The code iteratively designs a structure that minimizes the compliance (maximizes the stiffness) of the structure under the given loading, subject to an upper bound on the amount of material used. Depending on user options, the code can evaluate the performance of a user-designed structure, or create a design from scratch. Output includes the finite element mesh,more » design, and visualizations of the design.« less
Country Report on Building Energy Codes in Canada
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shui, Bin; Evans, Meredydd
2009-04-06
This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America . This reports gives an overview of the development of building energy codes in Canada, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, lighting, and water heating) for commercial and residential buildingsmore » in Canada.« less
Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Bing; Zhang, Jian; Chen, Yan
This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort,more » PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York. Section 2 of this report describes the analysis methodology, including the building types and construction area weights update for this analysis, the baseline, and the method to conduct the energy saving analysis. Section 3 provides detailed specifications of the EEMs and bundles. Section 4 summarizes the results of individual EEMs and EEM bundles by building type, energy end-use and climate zone. Appendix A documents detailed descriptions of the selected prototype buildings. Appendix B provides energy end-use breakdown results by building type for both the baseline code and stretch code in all climate zones.« less
Nevada National Security Site Radiation Protection Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2013-04-30
Title 10 Code of Federal Regulations (CFR) Part 835, “Occupational Radiation Protection,” establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada National Security Site (NNSS), related (on-site or off-site) U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operations, and environmental restoration off-site projects. This RPP section consists of general statementsmore » that are applicable to the NNSS as a whole. The RPP also includes a series of appendices which provide supporting detail for the associated NNSS Tennant Organizations (TOs). Appendix H, “Compliance Demonstration Table,” contains a cross-walk for the implementation of 10 CFR 835 requirements. This RPP does not contain any exemptions from the established 10 CFR 835 requirements. The RSPC and TOs are fully compliant with 10 CFR 835 and no additional funding is required in order to meet RPP commitments. No new programs or activities are needed to meet 10 CFR 835 requirements and there are no anticipated impacts to programs or activities that are not included in the RPP. There are no known constraints to implementing the RPP. No guides or technical standards are adopted in this RPP as a means to meet the requirements of 10 CFR 835.« less
Welding consumable selection for cryogenic (4{degrees}K) application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kane, S.F.; Siewert, T.A.
1994-12-31
Brookhaven National Laboratory (BNL) has begun construction of a large (3.8 kilometer circumference) heavy ion collider for the Department of Energy. The collider uses superconducting magnets, operating at 4{degrees}K in supercritical helium, which meets the definition of a pressure vessel. The ASME Boiler & Pressure Vessel Code grants an exemption from impact testing to certain metals, but only for operating temperatures down to 20{degrees}K. Research and the latest change to ASTM Standard E23 have invalidated Charpy testing at 4{degrees}K, thus compliance with the Code is not possible. This effort was undertaken to identify the weld process and weld material necessarymore » to comply with the intent of the Code (impact test) requirements, that is, to design a weld joint that will assure adequate fracture toughness. We will report the results of this development and testing, and conclude that nitrogen and maganese enhanced 385L provides a superior weld metal for 4{degrees}K cryogenic applications without the exaggerated purity concerns normally associated with superaustenitic weld materials. This development has been so successful that BNL has procured 15,000 pounds of this material for magnet production. Oxygen content, manifested as inclusion density, has the single most significant effect upon fracture toughness and impact strength. Finally, we report that GMAW is a viable welding process, using off-the-shelf equipment, for 4{degrees}K cryogenic applications.« less
Essays in renewable energy and emissions trading
NASA Astrophysics Data System (ADS)
Kneifel, Joshua D.
Environmental issues have become a key political issue over the past forty years and has resulted in the enactment of many different environmental policies. The three essays in this dissertation add to the literature of renewable energy policies and sulfur dioxide emissions trading. The first essay ascertains which state policies are accelerating deployment of non-hydropower renewable electricity generation capacity into a states electric power industry. As would be expected, policies that lead to significant increases in actual renewable capacity in that state either set a Renewables Portfolio Standard with a certain level of required renewable capacity or use Clean Energy Funds to directly fund utility-scale renewable capacity construction. A surprising result is that Required Green Power Options, a policy that merely requires all utilities in a state to offer the option for consumers to purchase renewable energy at a premium rate, has a sizable impact on non-hydro renewable capacity in that state. The second essay studies the theoretical impacts fuel contract constraints have on an electricity generating unit's compliance costs of meeting the emissions compliance restrictions set by Phase I of the Title IV SO2 Emissions Trading Program. Fuel contract constraints restrict a utility's degrees of freedom in coal purchasing options, which can lead to the use of a more expensive compliance option and higher compliance costs. The third essay analytically and empirically shows how fuel contract constraints impact the emissions allowance market and total electric power industry compliance costs. This paper uses generating unit-level simulations to replicate results from previous studies and show that fuel contracts appear to explain a large portion (65%) of the previously unexplained compliance cost simulations. Also, my study considers a more appropriate plant-level decisions for compliance choices by analytically analyzing the plant level decision-making process to show how cost-minimization at the more complex plant level may deviate from cost-minimization at the generating unit level.
10 CFR 150.17a - Compliance with requirements of US/IAEA Safeguards Agreement.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Compliance with requirements of US/IAEA Safeguards... Authority in Agreement States § 150.17a Compliance with requirements of US/IAEA Safeguards Agreement. (a... shall take other action as may be necessary to implement the US/IAEA Safeguards Agreement, as described...
10 CFR 150.17a - Compliance with requirements of US/IAEA Safeguards Agreement.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Compliance with requirements of US/IAEA Safeguards... Authority in Agreement States § 150.17a Compliance with requirements of US/IAEA Safeguards Agreement. (a... shall take other action as may be necessary to implement the US/IAEA Safeguards Agreement, as described...
A commercial building energy standard for Mexico
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, J.; Warner, J.L.; Wiel, S.
1998-07-01
Beginning in 1992, the Comission Nacional de Ahorro de Energia (CONAE), or Mexican National Commission for Energy Conservation, developed a national energy standard for commercial buildings, with assistance from USAID and LBNL. The first complete draft of the standard was released for public review in mid-1995. To promote public acceptance of the standard, CONAE held advisory meetings with architects, engineers, and utility representatives, and organized pubic workshops presented by the authors, with support from USAID. In response to industry comments, the standard was revised in late 1997 and is currently under review by CONAE. It is anticipated that the revisedmore » draft will be released again for final public comments in the summer of 1998. The standard will become law one year after it is finalized by CONAE and published in the federal government record. Since Mexico consists of cooling-dominated climates, the standard emphasizes energy-efficient envelope design to control solar and conductive heat gains. The authors extended DOE-2 simulation results for four climates to all of Mexico through regression analysis. Based on these results, they developed a simplified custom budget calculation approach. To facilitate the method's use, a calculation template was devised in a spreadsheet program and distributed to the public. CONAE anticipates that local engineering associations will use this spreadsheet to administer code compliance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cole, Pamala C.; Richman, Eric E.
2008-09-01
Feeling dim from energy code confusion? Read on to give your inspections a charge. The U.S. Department of Energy’s Building Energy Codes Program addresses hundreds of inquiries from the energy codes community every year. This article offers clarification for topics of confusion submitted to BECP Technical Support of interest to electrical inspectors, focusing on the residential and commercial energy code requirements based on the most recently published 2006 International Energy Conservation Code® and ANSI/ASHRAE/IESNA1 Standard 90.1-2004.
McInnes, Rhona J; Wright, Charlotte; Haq, Shogufta; McGranachan, Margaret
2007-07-01
To evaluate compliance with the World Health Organization's International Code of Marketing of Breast-milk Substitutes in primary care, after the introduction of strict local infant feeding guidelines. An audit form was sent to all community-based health professionals with an infant feeding remit. Walking tours were conducted in a random sample of community care facilities. Greater Glasgow Primary Care Division. (1) Primary-care staff with an infant feeding remit; (2) community health-care facilities. Contact with manufacturers of breast-milk substitutes (BMS) and BMS company personnel, free samples or incentives, and advertising of BMS. Contact with company personnel was minimal, usually unsolicited and was mainly to provide product information. Free samples of BMS or feeding equipment were rare but childcare or parenting literature was more prevalent. Staff voiced concerns about the lack of relevant information for bottle-feeding mothers and the need to support the mother's feeding choice. One-third of facilities were still displaying materials non-compliant with the Code, with the most common materials being weight conversion charts and posters. Contact between personnel from primary care and BMS companies was minimal and generally unsolicited. The presence of materials from BMS companies in health-care premises was more common. Due to the high level of bottle-feeding in Glasgow, primary-care staff stated a need for information about BMS.
Multimedia techniques for construction education and training : final report.
DOT National Transportation Integrated Search
2017-02-01
The current profession of civil engineering often focuses education and training on code compliance rather than constructability and construction techniques. Also, it is well accepted that it takes a decade or more for engineers to develop a high-lev...
76 FR 70807 - Notice of Passenger Facility Charge (PFC) Approvals and Disapprovals
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-15
... (design and construction). Enplane road structural improvements (design and construction). Landside signage improvements (design and construction). Taxiway B-2 extension and taxiway B-1 rehabilitation (design and construction). Elevator and escalator safety code compliance improvements (design and...
In this spreadsheet, user(s) provide their company’s manufacturer code, user contact information for EV-CIS, and user roles. This spreadsheet is used for the Company Authorizing Official (CAO), CROMERR Signer, and EV-CIS Submitters.
75 FR 52527 - New York Independent System Operator, Inc. Notice of Filings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-26
... Compliance Filing, New York Independent System Operator, Inc., 132 FERC 61,031 (July 15, 2010). Any person.... Kimberly D. Bose, Secretary. [FR Doc. 2010-21167 Filed 8-25-10; 8:45 am] BILLING CODE 6717-01-P ...
40 CFR 76.12 - Phase I NOX compliance extension.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...
40 CFR 76.12 - Phase I NOX compliance extension.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...
40 CFR 76.12 - Phase I NOX compliance extension.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...
40 CFR 76.12 - Phase I NOX compliance extension.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...
40 CFR 76.12 - Phase I NOX compliance extension.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...
Testimony of Granta Nakayama, Assistant Administrator for Enforcement and Compliance Assurance before the House Committee on Energy and Commerce, Subcommittee on Environment and Hazardous Materials, October 4, 2007.
Building Energy Codes: Policy Overview and Good Practices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cox, Sadie
2016-02-19
Globally, 32% of total final energy consumption is attributed to the building sector. To reduce energy consumption, energy codes set minimum energy efficiency standards for the building sector. With effective implementation, building energy codes can support energy cost savings and complementary benefits associated with electricity reliability, air quality improvement, greenhouse gas emission reduction, increased comfort, and economic and social development. This policy brief seeks to support building code policymakers and implementers in designing effective building code programs.
Why should I comply? Sellers' accounts for (non-)compliance with legal age limits for alcohol sales.
Gosselt, Jordy F; Van Hoof, Joris J; De Jong, Menno D T
2012-01-23
Availability is an important predictor of early and excessive alcohol consumption by adolescents. Many countries have implemented age limits to prevent underage purchases of alcohol. However, shop-floor compliance with these age limits appears to be problematic. This study addresses the issue of non-compliance with age limits. Which measures do vendors take to avoid underage alcohol sales, and what do they report as important reasons to comply or not with age limits for alcohol sales? Open-ended telephone interviews were conducted with store managers selling alcohol (N = 106). Prior to the interviews, all outlets were visited by an underage mystery shopper in order to measure compliance with the legal age limits on alcohol sales. The interview results are compared against actual compliance rates. Several measures have been taken to prevent underage sales, but the compliance level is low. Furthermore, open coding resulted in 19 themes, representing both valid and invalid arguments, that vendors mentioned as relevant to their decisions of whether to comply with the law. Compliance with age limits is dependent on the knowledge of the rules and the ability and motivation to follow the rules. The ability aspect in particular seems to be problematic, but in many cases, the motivation to actively comply with the age limits is lacking. To enhance compliance, it is important to raise the awareness of the importance of age limits and to connect possible violations of the regulations to negative consequences.
Why should i comply? Sellers' accounts for (non-)compliance with legal age limits for alcohol sales
2012-01-01
Background Availability is an important predictor of early and excessive alcohol consumption by adolescents. Many countries have implemented age limits to prevent underage purchases of alcohol. However, shop-floor compliance with these age limits appears to be problematic. This study addresses the issue of non-compliance with age limits. Which measures do vendors take to avoid underage alcohol sales, and what do they report as important reasons to comply or not with age limits for alcohol sales? Methods Open-ended telephone interviews were conducted with store managers selling alcohol (N = 106). Prior to the interviews, all outlets were visited by an underage mystery shopper in order to measure compliance with the legal age limits on alcohol sales. The interview results are compared against actual compliance rates. Results Several measures have been taken to prevent underage sales, but the compliance level is low. Furthermore, open coding resulted in 19 themes, representing both valid and invalid arguments, that vendors mentioned as relevant to their decisions of whether to comply with the law. Compliance with age limits is dependent on the knowledge of the rules and the ability and motivation to follow the rules. The ability aspect in particular seems to be problematic, but in many cases, the motivation to actively comply with the age limits is lacking. Conclusions To enhance compliance, it is important to raise the awareness of the importance of age limits and to connect possible violations of the regulations to negative consequences. PMID:22269016
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, W.E.
1995-12-01
On February 3, 1993, US DOE Richland Operations Office received a Compliance Order and Information Request from the Director of the Air and Toxics Div. of US EPA, Region X. The compliance order requires the Richland Operations Office to evaluate all radionuclide emission points at the Hanford site to determine which are subject to the continuous emission measurement requirements in Title 40, Code of Federal Regulations (CFR), Part 61, Subpart H, and to continuously measure radionuclide emissions in accordance with 40 CFR 61.93. The Information Request required The provision of a written compliance plan to meet the requirements of themore » compliance order. A compliance plan was submitted to EPA, Region X, on April 30, 1993. It set as one of the milestones, the complete assessment of the Hanford Site 84 stacks registered with the Washington State Department of Health, by December 17, 1993. This milestone was accomplished. The compliance plan also called for reaching a Federal Facility Compliance Agreement; this was reached on February 7, 1994, between DOE Richland Operations and EPA, Region X. The milestone to assess the unregistered stacks (powered exhaust) by August 31, 1994, was met. This update presents assessments for 72 registered and 22 unregistered stacks with potential emissions > 0.1 mrem/yr.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Springer, David; German, Alea
Building cost-effective, high-performance homes that provide superior comfort, health, and durability is the goal of the U.S. Department of Energy’s (DOE’s) Zero Energy Ready Home (ZERH) program. Building America research and other innovative programs throughout the country have addressed many of the technical challenges of building to the ZERH standard. The cost-effectiveness of measure packages that result in 30% source energy savings compared to a code-compliant home have been demonstrated. However, additional challenges remain, particularly with respect to convincing production builders of the strong business case for ZERH. The Alliance for Residential Building Innovation (ARBI) team believes that the keysmore » to successfully engaging builders and developers in the California market are to help them leverage development agreement requirements, code compliance requirements, incentives, and competitive market advantages of ZERH certification, and navigate through this process. A primary objective of this project was to gain a highly visible foothold for residential buildings that are built to the DOE ZERH specification that can be used to encourage participation by other California builders. This report briefly describes two single-family homes that were ZERH certified and focuses on the experience of working with developer Mutual Housing on a 62-unit multifamily community at the Spring Lake subdivision in Woodland, California. The Spring Lake project is expected to be the first ZERH-certified multifamily project in the country. This report discusses the challenges encountered, lessons learned, and how obstacles were overcome.« less
Need for Systematic Retrofit Analysis in Multifamily Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malhotra, Mini; Im, Piljae
2014-01-01
Multifamily housing offers high potential for energy savings through retrofits. A comprehensive energy audit with systematic evaluation of alternative energy measures is one of the key steps to realizing the full energy savings potential. However, this potential often remains unrealized when the selection of measures is (1) based on a one-size-fits-all approach originating from accustomed practices, (2) intended merely to meet code-compliance requirements, and/or (3) influenced by owner renter split incentive. In such cases, the benefits of comprehensive energy auditing are disregarded in view of the apparent difficulty in diagnosing multifamily buildings, evaluating alternative measures, and installing customized sets ofmore » measures. This paper highlights some of the barriers encountered in a multifamily housing retrofit project in Georgia and demonstrates the merits of systematic retrofit analysis by identifying opportunities for higher energy savings and improved comfort and indoor air quality that were missed in this project. The study uses a whole-building energy analysis conducted for a 10-unit, low-rise, multifamily building of a 110-unit apartment complex. The analysis projected a 24% energy savings from the measures installed in the building with a payback period of 10 years. Further analysis with a systematic evaluation of alternative measures showed that without compromising on the objectives of durability, livability, and appearance of the building, energy savings of up to 34% were achievable with a payback period of 7 years. The paper concludes by outlining recommendations that may benefit future retrofit projects by improving the audit process, streamlining tasks, and achieving higher energy savings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The final rule of the Energy Policy Act of 2005 and its associated regulations enable covered state and alternative fuel provider fleets to obtain waivers from the alternative fuel vehicle (AFV)-acquisition requirements of Standard Compliance. Under Alternative Compliance, covered fleets instead meet a petroleum-use reduction requirement. This guidance document is designed to help fleets better understand the Alternative Compliance option and successfully complete the waiver application process.
Analysis of Air Force Compliance with Executive Order 13149
2004-03-23
9 Department of Defense Compliance Strategy for Executive Order 13149..................13...White House, 2000). Each agency is required to have a compliance strategy outlining the steps they are going to take to accomplish the 20 percent...mandatory components of any strategy . “Each agency shall fulfill the acquisition requirements for AFVs established by section 303 of the Energy Policy
From Policy to Compliance: Federal Energy Efficient Product Procurement
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeMates, Laurèn; Scodel, Anna
Federal buyers are required to purchase energy-efficient products in an effort to minimize energy use in the federal sector, save the federal government money, and spur market development of efficient products. The Federal Energy Management Program (FEMP)’s Energy Efficient Product Procurement (EEPP) Program helps federal agencies comply with the requirement to purchase energy-efficient products by providing technical assistance and guidance and setting efficiency requirements for certain product categories. Past studies have estimated the savings potential of purchasing energy-efficient products at over $500 million per year in energy costs across federal agencies.1 Despite the strong policy support for EEPP and resourcesmore » available, energy-efficient product purchasing operates within complex decision-making processes and operational structures; implementation challenges exist that may hinder agencies’ ability to comply with purchasing requirements. The shift to purchasing green products, including energy-efficient products, relies on “buy in” from a variety of potential actors throughout different purchasing pathways. Challenges may be especially high for EEPP relative to other sustainable acquisition programs given that efficient products frequently have a higher first cost than non-efficient ones, which may be perceived as a conflict with fiscal responsibility, or more simply problematic for agency personnel trying to stretch limited budgets. Federal buyers may also face challenges in determining whether a given product is subject to EEPP requirements. Previous analysis on agency compliance with EEPP, conducted by the Alliance to Save Energy (ASE), shows that federal agencies are getting better at purchasing energy-efficient products. ASE conducted two reviews of relevant solicitations for product and service contracts listed on Federal Business Opportunities (FBO), the centralized website where federal agencies are required to post procurements greater than $25,000. In 2010, ASE estimated a compliance rate of 46% in 2010, up from an estimate of 12% in 2008. Our work updates and expands on ASE’s 2010 analysis to gauge agency compliance with EEPP requirements.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Definitions. 1193.3 Section 1193.3 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD... communications through the transmission of coded signals across the standard telephone network. TTYs can include...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Definitions. 1193.3 Section 1193.3 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD... communications through the transmission of coded signals across the standard telephone network. TTYs can include...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Definitions. 1193.3 Section 1193.3 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD... communications through the transmission of coded signals across the standard telephone network. TTYs can include...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Definitions. 1193.3 Section 1193.3 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD... communications through the transmission of coded signals across the standard telephone network. TTYs can include...
49 CFR 41.119 - DOT regulated buildings.
Code of Federal Regulations, 2011 CFR
2011-10-01
... compliance may include the engineer's and architect's authenticated verification of seismic design codes... and additions to existing buildings will ensure that each DOT regulated building is designed and constructed in accord with seismic design and construction standards as provided by this part. (b) This...
Kelly, Kandace; Harrington, Linda; Matos, Pat; Turner, Barbara; Johnson, Constance
2016-01-01
Bar-code medication administration (BCMA) effectiveness is contingent upon compliance with best-practice protocols. We developed a 4-phased BCMA evaluation program to evaluate the degree of integration of current evidence into BCMA policies, procedures, and practices; identify barriers to best-practice BCMA use; and modify BCMA practice in concert with changes to the practice environment. This program provides an infrastructure for frontline nurses to partner with hospital leaders to continually evaluate and improve BCMA using a systematic process.
Federal Facilities Reports About Underground Storage Tank Compliance - 2005 Energy Policy Act
Find links to reports from 24 federal agencies regarding the compliance status of underground storage tanks owned or operated by the federal agencies or located on land managed by the federal agencies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
This annual report of the Alternative Fuel Transportation Program, which ensures compliance with DOE regulations covering state government and alternative fuel provider fleets pursuant to the Energy Policy Act of 1992 (EPAct), as amended, provides fleet compliance results for manufacturing year 2014 / fiscal year 2015.
Environmental Compliance Guide
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1981-02-01
The Guide is intended to assist Department of Energy personnel by providing information on the NEPA process, the processes of other environmental statutes that bear on the NEPA process, the timing relationships between the NEPA process and these other processes, as well as timing relationships between the NEPA process and the development process for policies, programs, and projects. This information should be helpful not only in formulating environmental compliance plans but also in achieving compliance with NEPA and various other environmental statutes. The Guide is divided into three parts with related appendices: Part I provides guidance for developing environmental compliancemore » plans for DOE actions; Part II is devoted to NEPA with detailed flowcharts depicting the compliance procedures required by CEQ regulations and Department of Energy NEPA Guidelines; and Part III contains a series of flowcharts for other Federal environmental requirements that may apply to DOE projects.« less
A long-term, integrated impact assessment of alternative building energy code scenarios in China
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Sha; Eom, Jiyong; Evans, Meredydd
2014-04-01
China is the second largest building energy user in the world, ranking first and third in residential and commercial energy consumption. Beginning in the early 1980s, the Chinese government has developed a variety of building energy codes to improve building energy efficiency and reduce total energy demand. This paper studies the impact of building energy codes on energy use and CO2 emissions by using a detailed building energy model that represents four distinct climate zones each with three building types, nested in a long-term integrated assessment framework GCAM. An advanced building stock module, coupled with the building energy model, ismore » developed to reflect the characteristics of future building stock and its interaction with the development of building energy codes in China. This paper also evaluates the impacts of building codes on building energy demand in the presence of economy-wide carbon policy. We find that building energy codes would reduce Chinese building energy use by 13% - 22% depending on building code scenarios, with a similar effect preserved even under the carbon policy. The impact of building energy codes shows regional and sectoral variation due to regionally differentiated responses of heating and cooling services to shell efficiency improvement.« less
Pressure Safety Program Implementation at ORNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lower, Mark; Etheridge, Tom; Oland, C. Barry
2013-01-01
The Oak Ridge National Laboratory (ORNL) is a US Department of Energy (DOE) facility that is managed by UT-Battelle, LLC. In February 2006, DOE promulgated worker safety and health regulations to govern contractor activities at DOE sites. These regulations, which are provided in 10 CFR 851, Worker Safety and Health Program, establish requirements for worker safety and health program that reduce or prevent occupational injuries, illnesses, and accidental losses by providing DOE contractors and their workers with safe and healthful workplaces at DOE sites. The regulations state that contractors must achieve compliance no later than May 25, 2007. According tomore » 10 CFR 851, Subpart C, Specific Program Requirements, contractors must have a structured approach to their worker safety and health programs that at a minimum includes provisions for pressure safety. In implementing the structured approach for pressure safety, contractors must establish safety policies and procedures to ensure that pressure systems are designed, fabricated, tested, inspected, maintained, repaired, and operated by trained, qualified personnel in accordance with applicable sound engineering principles. In addition, contractors must ensure that all pressure vessels, boilers, air receivers, and supporting piping systems conform to (1) applicable American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (2004) Sections I through XII, including applicable code cases; (2) applicable ASME B31 piping codes; and (3) the strictest applicable state and local codes. When national consensus codes are not applicable because of pressure range, vessel geometry, use of special materials, etc., contractors must implement measures to provide equivalent protection and ensure a level of safety greater than or equal to the level of protection afforded by the ASME or applicable state or local codes. This report documents the work performed to address legacy pressure vessel deficiencies and comply with pressure safety requirements in 10 CFR 851. It also describes actions taken to develop and implement ORNL’s Pressure Safety Program.« less
10 CFR 434.99 - Explanation of numbering system for codes.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Explanation of numbering system for codes. 434.99 Section 434.99 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS § 434.99 Explanation of numbering system for codes. (a) For...
10 CFR 434.99 - Explanation of numbering system for codes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Explanation of numbering system for codes. 434.99 Section 434.99 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS § 434.99 Explanation of numbering system for codes. (a) For...
Potential Job Creation in Rhode Island as a Result of Adopting New Residential Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Michael J.; Niemeyer, Jackie M.
Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less
Potential Job Creation in Minnesota as a Result of Adopting New Residential Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Michael J.; Niemeyer, Jackie M.
Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less
Potential Job Creation in Tennessee as a Result of Adopting New Residential Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Michael J.; Niemeyer, Jackie M.
Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less
Potential Job Creation in Nevada as a Result of Adopting New Residential Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Michael J.; Niemeyer, Jackie M.
Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-24
...: Philip Egidi, Radiation Protection Division, Center for Waste Management and Regulations, (Mail code... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OAR-2003-0085; FRL-9622-1] Agency Information Collection... AGENCY: Environmental Protection Agency. ACTION: Notice. SUMMARY: In compliance with the Paperwork...
Chargemaster maintenance: think 'spring cleaning' all year round.
Barton, Shawn; Lancaster, Dani; Bieker, Mike
2008-11-01
Steps toward maintaining a standardized chargemaster include: Building a corporate chargemaster maintenance team. Developing a core research function. Designating hospital liaisons. Publishing timely reports on facility compliance. Using system codes to identify charges. Selecting chargemaster maintenance software. Developing a standard chargemaster data repository. Educating staff.
42 CFR 433.37 - Reporting provider payments to Internal Revenue Service.
Code of Federal Regulations, 2010 CFR
2010-10-01
... identification of providers by— (1) Social security number if— (i) The provider is in solo practice; or (ii) The... security number or employer identification number. ... identification number for all other providers. (c) Compliance with section 6041 of the Internal Revenue Code. The...
Ostfeld-Etzion, Sharon; Feldman, Ruth; Hirschler-Guttenberg, Yael; Laor, Nathaniel; Golan, Ofer
2016-10-01
Regulatory difficulties are common in children with autism spectrum disorder. This study focused on an important aspect of self-regulation-the ability to willingly comply with frustrating demands of socialization agents, termed "self-regulated compliance." We studied compliance to parental demands in 40 preschoolers with autism spectrum disorder and 40 matched typically developing preschoolers, during separate interactions with mother and father, while engaging in two paradigms: toy pick-up and delayed gratification, which tap the "do" and "don't" aspects of self-regulated socialization at this age. Parents' disciplinary style was micro-coded from the two paradigms and child temperament was parent reported. Compared to their typically developing peers, children with autism spectrum disorder showed more noncompliance and less self-regulated compliance to parental demands and prohibitions and greater temperamental difficulties across several domains. No group differences were found in parental disciplinary style. Child self-regulated compliance was associated with parental supportive disciplinary style and with child attention focusing. Findings highlight the importance of parental supportive presence in structuring the development of socialization in children with autism spectrum disorder. Implications for parent-child emotion regulation interventions are discussed. © The Author(s) 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Byoung Yoon; Hansen, Francis D.
2005-07-01
This report develops a series of porosity surfaces for the Waste Isolation Pilot Plant. The concept of a porosity surface was developed for performance assessment and comprises calculation of room closure as salt creep processes are mitigated by gas generation and back stress created by the waste packages within the rooms. The physical and mechanical characteristics of the waste packaging that has already been disposed--such as the pipe overpack--and new waste packaging--such as the advanced mixed waste compaction--are appreciably different than the waste form upon which the original compliance was based and approved. This report provides structural analyses of roommore » closure with various waste inventories. All of the underlying assumptions pertaining to the original compliance certification including the same finite element code are implemented; only the material parameters describing the more robust waste packages are changed from the certified baseline. As modeled, the more rigid waste tends to hold open the rooms and create relatively more void space in the underground than identical calculations run on the standard waste packages, which underpin the compliance certification. The several porosity surfaces quantified within this report provide possible ranges of pressure and porosity for performance assessment analyses.3 Intentionally blank4 AcknowledgementsThis research is funded by WIPP programs administered by the U.S. Department of Energy. The authors would like to acknowledge the valuable contributions to this work provided by others. Dr. Joshua S. Stein helped explain the hand off between these finite element porosity surfaces and implementation in the performance calculations. Dr. Leo L. Van Sambeek of RESPEC Inc. helped us understand the concepts of room closure under the circumstances created by a rigid waste inventory. Dr. T. William Thompson and Tom W. Pfeifle provided technical review and Mario J. Chavez provided a Quality Assurance review. The paper has been improved by these individuals.Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94Al850005 Intentionally Blank6« less
This working paper examines the effect of increased inspection frequency occurring under the Energy Policy Act of 2005 on compliance with release detection and prevention requirements at underground storage tank facilities in Louisiana.
1998 report on Hanford Site land disposal restrictions for mixed waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Black, D.G.
1998-04-10
This report was submitted to meet the requirements of Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-26-01H. This milestone requires the preparation of an annual report that covers characterization, treatment, storage, minimization, and other aspects of managing land-disposal-restricted mixed waste at the Hanford Facility. The US Department of Energy, its predecessors, and contractors on the Hanford Facility were involved in the production and purification of nuclear defense materials from the early 1940s to the late 1980s. These production activities have generated large quantities of liquid and solid mixed waste. This waste is regulated under authority of bothmore » the Resource Conservation and Recovery Act of l976 and the Atomic Energy Act of 1954. This report covers only mixed waste. The Washington State Department of Ecology, US Environmental Protection Agency, and US Department of Energy have entered into the Tri-Party Agreement to bring the Hanford Facility operations into compliance with dangerous waste regulations. The Tri-Party Agreement required development of the original land disposal restrictions (LDR) plan and its annual updates to comply with LDR requirements for mixed waste. This report is the eighth update of the plan first issued in 1990. The Tri-Party Agreement requires and the baseline plan and annual update reports provide the following information: (1) Waste Characterization Information -- Provides information about characterizing each LDR mixed waste stream. The sampling and analysis methods and protocols, past characterization results, and, where available, a schedule for providing the characterization information are discussed. (2) Storage Data -- Identifies and describes the mixed waste on the Hanford Facility. Storage data include the Resource Conservation and Recovery Act of 1976 dangerous waste codes, generator process knowledge needed to identify the waste and to make LDR determinations, quantities stored, generation rates, location and method of storage, an assessment of storage-unit compliance status, storage capacity, and the bases and assumptions used in making the estimates.« less