Compressive behavior of energy-saving fired facing brick composite wall
NASA Astrophysics Data System (ADS)
Guo, Kai; Wu, Cai
2018-03-01
The energy-saving fired facing brick composite wall has a broad development prospects due to its merits of thermal insulation, energy conservation, beautiful, and natural. The construction and characteristics of this wall are introduced and analyzed in this paper. Experimental studies of samples are also conducted to investigate its compressive performance. The results show that the energy-saving fired facing brick composite wall has high compressive capacity. It has considerable application prospect, the study in this paper provides foundation to further studies.
Laboratory investigation of fire radiative energy and smoke aerosol emissions
Charles Ichoku; J. Vanderlei Martins; Yoram J. Kaufman; Martin J. Wooster; Patrick H. Freeborn; Wei Min Hao; Stephen Baker; Cecily A. Ryan; Bryce L. Nordgren
2008-01-01
Fuel biomass samples from southern Africa and the United States were burned in a laboratory combustion chamber while measuring the biomass consumption rate, the fire radiative energy (FRE) release rate (Rfre), and the smoke concentrations of carbon monoxide (CO), carbon dioxide (CO2), and particulate matter (PM). The PM mass emission rate (RPM) was quantified from...
EFFECT OF CONVENTIONAL AND ADVANCED COAL CONVERSION BY-PRODUCTS ON THE PULMONARY SYSTEM
To evaluate the environmental impact of different energy technologies, fly ash samples collected from a coal-fired and from an oil-fired electric power plant were used in aerosol inhalation exposures of mice. The effects of multiple 3-h exposures to the fly ash particles at 2 and...
Moderate Image Spectrometer (MODIS) Fire Radiative Energy: Physics and Applications
NASA Technical Reports Server (NTRS)
Kaufman, Y.
2004-01-01
MODIS fire channel does not saturate in the presence of fires. The fire channel therefore is used to estimate the fire radiative energy, a measure of the rate of biomass consumption in the fire. We found correlation between the fire radiative energy, the rate of formation of burn scars and the rate of emission of aerosol from the fires. Others found correlations between the fire radiative energy and the rate of biomass consumption. This relationships can be used to estimates the emissions from the fires and to estimate the fire hazards.
Soils Data Related to the 1999 FROSTFIRE Burn
Manies, K.L.; Harden, J.W.; Ottmar, R.
2011-01-01
This report describes the sample collection and processing for U.S. Geological Survey efforts at FROSTFIRE, an experimental burn that occurred in Alaska in 1999. Data regarding carbon, water, and energy dynamics pre-fire, during, and post-fire were obtained in this landscape-scale prescribed burn. U.S. Geological Survey investigators measured changes in the stocks of carbon (C), nitrogen (N), mercury (Hg), and other components in pre- and post-burn soils of this watershed.
Hogg, Seth R; Hunter, Brian C; Waddell Smith, Ruth
2016-01-01
Concerns over the toxic by-products produced by traditional ammunition have led to an increase in popularity of nontoxic ammunition. In this work, the chemical composition of six brands of nontoxic ammunition was investigated and compared to that of a road flare, which served as an environmental source with similar composition. Five rounds of each brand were fired while a further five were disassembled and the primer alone was fired. Particles collected from all samples, including the road flare, were analyzed by scanning electron microscopy with energy dispersive X-ray analysis. Common elements among the different ammunition brands included aluminum, potassium, silicon, calcium, and strontium. Spectra were then subjected to principal components analysis in which association of the primer to the intact ammunition sample was generally possible, with distinction among brands and from the road flare sample. Further, PCA loadings plots indicated the elements responsible for the association and discrimination observed. © 2015 American Academy of Forensic Sciences.
High explosive spot test analyses of samples from Operable Unit (OU) 1111
DOE Office of Scientific and Technical Information (OSTI.GOV)
McRae, D.; Haywood, W.; Powell, J.
1995-01-01
A preliminary evaluation has been completed of environmental contaminants at selected sites within the Group DX-10 (formally Group M-7) area. Soil samples taken from specific locations at this detonator facility were analyzed for harmful metals and screened for explosives. A sanitary outflow, a burn pit, a pentaerythritol tetranitrate (PETN) production outflow field, an active firing chamber, an inactive firing chamber, and a leach field were sampled. Energy dispersive x-ray fluorescence (EDXRF) was used to obtain semi-quantitative concentrations of metals in the soil. Two field spot-test kits for explosives were used to assess the presence of energetic materials in the soilmore » and in items found at the areas tested. PETN is the major explosive in detonators manufactured and destroyed at Los Alamos. No measurable amounts of PETN or other explosives were detected in the soil, but items taken from the burn area and a high-energy explosive (HE)/chemical sump were contaminated. The concentrations of lead, mercury, and uranium are given.« less
Wang, Qian; Liu, Zhen; Ziegler, Sibylle I; Shi, Kuangyu
2015-07-07
Position-sensitive positron cameras using silicon pixel detectors have been applied for some preclinical and intraoperative clinical applications. However, the spatial resolution of a positron camera is limited by positron multiple scattering in the detector. An incident positron may fire a number of successive pixels on the imaging plane. It is still impossible to capture the primary fired pixel along a particle trajectory by hardware or to perceive the pixel firing sequence by direct observation. Here, we propose a novel data-driven method to improve the spatial resolution by classifying the primary pixels within the detector using support vector machine. A classification model is constructed by learning the features of positron trajectories based on Monte-Carlo simulations using Geant4. Topological and energy features of pixels fired by (18)F positrons were considered for the training and classification. After applying the classification model on measurements, the primary fired pixels of the positron tracks in the silicon detector were estimated. The method was tested and assessed for [(18)F]FDG imaging of an absorbing edge protocol and a leaf sample. The proposed method improved the spatial resolution from 154.6 ± 4.2 µm (energy weighted centroid approximation) to 132.3 ± 3.5 µm in the absorbing edge measurements. For the positron imaging of a leaf sample, the proposed method achieved lower root mean square error relative to phosphor plate imaging, and higher similarity with the reference optical image. The improvements of the preliminary results support further investigation of the proposed algorithm for the enhancement of positron imaging in clinical and preclinical applications.
NASA Astrophysics Data System (ADS)
Wang, Qian; Liu, Zhen; Ziegler, Sibylle I.; Shi, Kuangyu
2015-07-01
Position-sensitive positron cameras using silicon pixel detectors have been applied for some preclinical and intraoperative clinical applications. However, the spatial resolution of a positron camera is limited by positron multiple scattering in the detector. An incident positron may fire a number of successive pixels on the imaging plane. It is still impossible to capture the primary fired pixel along a particle trajectory by hardware or to perceive the pixel firing sequence by direct observation. Here, we propose a novel data-driven method to improve the spatial resolution by classifying the primary pixels within the detector using support vector machine. A classification model is constructed by learning the features of positron trajectories based on Monte-Carlo simulations using Geant4. Topological and energy features of pixels fired by 18F positrons were considered for the training and classification. After applying the classification model on measurements, the primary fired pixels of the positron tracks in the silicon detector were estimated. The method was tested and assessed for [18F]FDG imaging of an absorbing edge protocol and a leaf sample. The proposed method improved the spatial resolution from 154.6 ± 4.2 µm (energy weighted centroid approximation) to 132.3 ± 3.5 µm in the absorbing edge measurements. For the positron imaging of a leaf sample, the proposed method achieved lower root mean square error relative to phosphor plate imaging, and higher similarity with the reference optical image. The improvements of the preliminary results support further investigation of the proposed algorithm for the enhancement of positron imaging in clinical and preclinical applications.
Andrew T. Hudak; Matthew B. Dickinson; Benjamin C. Bright; Robert L. Kremens; E. Louise Loudermilk; Joseph J. O' Brien; Benjamin S. Hornsby; Roger D. Ottmar
2016-01-01
Small-scale experiments have demonstrated that fire radiative energy is linearly related to fuel combusted but such a relationship has not been shown at the landscape level of prescribed fires. This paper presents field and remotely sensed measures of pre-fire fuel loads, consumption, fire radiative energy density (FRED) and fire radiative power flux density (FRFD),...
NASA Astrophysics Data System (ADS)
Klauberg Silva, C.; Hudak, A. T.; Bright, B. C.; Dickinson, M. B.; Kremens, R.; Paugam, R.; Mell, W.
2016-12-01
Biomass burning has impacts on air pollution at local to regional scales and contributes to greenhouse gases and affects carbon balance at the global scale. Therefore, is important to accurately estimate and manage carbon pools (fuels) and fluxes (gases and particulate emissions having public health implications) associated with wildland fires. Fire radiative energy (FRE) has been shown to be linearly correlated with biomass burned in small-scale experimental fires but not at the landscape level. Characterization of FRE density (FRED) flux in J m-2 from a landscape-level fire presents an undersampling problem. Specifically, airborne acquisitions of long-wave infrared radiation (LWIR) from a nadir-viewing LWIR camera mounted on board fixed-wing aircraft provide only samples of FRED from a landscape-level fire, because of the time required to turn the plane around between passes, and a fire extent that is broader than the camera field of view. This undersampling in time and space produces apparent firelines in an image of observed FRED, capturing the fire spread only whenever and wherever the scene happened to be imaged. We applied ordinary kriging to images of observed FRED from five prescribed burns collected in forested and non-forested management units burned at Eglin Air Force Base in Florida USA in 2011 and 2012. The three objectives were to: 1. more realistically map FRED, 2. more accurately estimate total FRED as predicted from fuel consumption measurements, and 3. compare the sampled and kriged FRED maps to modeled estimates of fire rate of spread (ROS). Observed FRED was integrated from LWIR images calibrated to units of fire radiative flux density (FRFD) in W m-2. Iterating the kriging analysis 2-10 times (depending on the burn unit) led to more accurate FRED estimates, both in map form and in terms of total FRED, as corroborated by independent estimates of fuel consumption and ROS.
Electronic firing systems and methods for firing a device
Frickey, Steven J [Boise, ID; Svoboda, John M [Idaho Falls, ID
2012-04-24
An electronic firing system comprising a control system, a charging system, an electrical energy storage device, a shock tube firing circuit, a shock tube connector, a blasting cap firing circuit, and a blasting cap connector. The control system controls the charging system, which charges the electrical energy storage device. The control system also controls the shock tube firing circuit and the blasting cap firing circuit. When desired, the control system signals the shock tube firing circuit or blasting cap firing circuit to electrically connect the electrical energy storage device to the shock tube connector or the blasting cap connector respectively.
Canadian and Siberian Boreal Fire Activity during ARCTAS Spring and Summer Phases
NASA Astrophysics Data System (ADS)
Stocks, B. J.; Fromm, M. D.; Soja, A. J.; Servranckx, R.; Lindsey, D.; Hyer, E.
2009-12-01
The summer phase of ARCTAS (Arctic Research of the Composition of the Troposphere from Aircraft and Satellites) was designed specifically around forest fire activity in the Canadian boreal forest, and located in areas of northern Canada where summer forest fires are ubiquitous. Lightning fires are most often allowed to burn naturally in these regions, and a number of large free-burning fires in northern Saskatchewan in late June/early July 2008 provided excellent targets during the summer phase of ARCTAS. Smoke generated by a large number of early spring fires in Kazakhstan and southern Siberia unexpectedly made a significant contribution to arctic haze during the Alaska-based spring phase of ARCTAS, Numerous smoke plumes were sampled during the spring phase of ARCTAS, creating interest in the origin and characteristics of the fires in the source regions of East Asia. This presentation is designed to connect aircraft and satellite smoke chemistry/transport measurements with ground-based measurements of fire activity during the spring and summer phases of ARCTAS. The Canadian Forest Fire Danger Rating System (CFFDRS) is used to determine forest fire danger conditions in regions of fire activity, and these measurements are in turn used to project fire behavior characteristics. Fuel consumption, spread rates, and frontal fire intensity are calculated using the CFFDRS. Energy release rates at ground level are related to convection/smoke column development and smoke injection heights.
NASA Astrophysics Data System (ADS)
Blantocas, Gene Q.; Mateum, Philip Edward R.; Orille, Ross William M.; Ramos, Rafael Julius U.; Monasterial, Jonathan Lee C.; Ramos, Henry J.; Bo-ot, Luis Ma. T.
2007-06-01
Changes on the properties of wood irradiated by low energy hydrogen ion showers (LEHIS) were examined. The experimental facility employed was an in-house constructed, compact gas discharge ion source with beam energies maintained approximately in the 1 keV range fixed at 1 mA discharge current, 3 mTorr gas filling pressure. Wood specimens used were of species endemic in the Philippines namely Shorea sp., Shorea polysperma and Cocos nucifera. Results showed the processed samples manifested characteristics of inhibited flammability, and became relatively hydrophobic after the treatment. In the fire resistance test, it was also observed during initial flaming that the processed surfaces accumulated less soot attesting to a much lower smoldering rate, i.e. lesser combustibility. To assess the increase in fire endurance time for the processed wood against the control substrates, a non-directional, two-tailed t-test was utilized. Significant at the 0.05 level, the t-statistic measured 9.164 as opposed to only 4.303 in its corresponding critical value at two degrees of freedom. Hence, the treatment appeared to show strong statistical evidence of being effective in enhancing fire resistance. The processed specimens also exhibited moisture absorptive inhibition time of more than 10 min versus an average absorption period of just 8 s for the unprocessed samples. Spectroscopy using a cast steel mass analyzer indicated a predominance of H+ with faint signals of H2+in the ion showers. It is hypothesized that the monatomic ion plays an essential participatory role in the surface modification process. Data from an earlier work using Narra wood (Pterocarpus indicus) [G.Q. Blantocas, H.J. Ramos, M. Wada, Jpn. J. Appl. Phys. 45 (2006) 8498] was extended in the current study to substantiate this hypothesis. The data is now presented as current density ratio H+ /H2+versus the change rate constant K of the wetting model equation. It is shown that wood affinity to water decreased as the proportion of H+ increased, i.e. higher flux density ratios favored surface inactivation. It is further demonstrated using hardwood samples that a dominance of H+ also improved fire resistance. H+ ions seemed to be the initiator in the formation of hydrophobic and flame resistant wood surfaces. In contrast, high energy showers (⩾900 eV) resulted in lower H+ /H2+ratios. Samples exposed to showers in these energy ranges showed decreased flame resistance. They degraded more rapidly during flaming. Finally, a comparison of SEM images showed surface smoothening of the processed samples. The LEHIS method proved benign showing no unfavorable effects on paint adherence and original texture and color. This plasma-based procedure could probably be developed as an alternative mode of wood preservation.
NASA Technical Reports Server (NTRS)
Ichoku, Charles; Kaufman, Yoram J.; Hao, Wei Min; Habib, Shahid
2004-01-01
The radiative energy emitted by large fires and the corresponding smoke aerosol loading are simultaneously measured from the MODIS sensor from both the Terra and Aqua satellites. Quantitative relationships between the rates of emission of fire radiative energy and smoke are being developed for different fire-prone regions of the globe. Preliminary results are presented. When fully developed, the system will enable the use of MODIS direct broadcast fire data for near real-time monitoring of fire strength and smoke emission as well as forecasting of fire progression and smoke dispersion, several hours to a few days in advance.
Clean Power Generation from the Intractable Natural Coalfield Fires: Turn Harm into Benefit.
Shi, Bobo; Su, Hetao; Li, Jinshi; Qi, Haining; Zhou, Fubao; Torero, José L; Chen, Zhongwei
2017-07-13
The coal fires, a global catastrophe for hundreds of years, have been proved extremely difficult to control, and hit almost every coal-bearing area globally. Meanwhile, underground coal fires contain tremendous reservoir of geothermal energy. Approximately one billion tons of coal burns underground annually in the world, which could generate ~1000 GW per annum. A game-changing approach, environmentally sound thermal energy extraction from the intractable natural coalfield fires, is being developed by utilizing the waste energy and reducing the temperature of coalfield fires at the same time. Based on the Seebeck effect of thermoelectric materials, the temperature difference between the heat medium and cooling medium was employed to directly convert thermal energy into clean electrical energy. By the time of December 2016, the power generation from a single borehole at Daquan Lake fire district in Xinjiang has been exceeded 174.6 W. The field trial demonstrates that it is possible to exploit and utilize the waste heat resources in the treated coal fire areas. It promises a significant impact on the structure of global energy generation and can also promote progress in thermoelectric conversion materials, geothermal exploration, underground coal fires control and other energy related areas.
Testing electroexplosive devices by programmed pulsing techniques
NASA Technical Reports Server (NTRS)
Rosenthal, L. A.; Menichelli, V. J.
1976-01-01
A novel method for testing electroexplosive devices is proposed wherein capacitor discharge pulses, with increasing energy in a step-wise fashion, are delivered to the device under test. The size of the energy increment can be programmed so that firing takes place after many, or after only a few, steps. The testing cycle is automatically terminated upon firing. An energy-firing contour relating the energy required to the programmed step size describes the single-pulse firing energy and the possible sensitization or desensitization of the explosive device.
Radiant flux density, energy density, and fuel consumption in mixed-oak forest surface fires
R.L. Kremens; M.B. Dickinson; A.S. Bova
2012-01-01
Closing the wildland fire heat budget involves characterising the heat source and energy dissipation across the range of variability in fuels and fire behaviour. Meeting this challenge will lay the foundation for predicting direct ecological effects of fires and fire-atmosphere coupling. In this paper, we focus on the relationships between the fire radiation field, as...
The Science and Application of Satellite Based Fire Radiative Energy
NASA Technical Reports Server (NTRS)
Ellicott, Evan; Vermote, Eric (Editor)
2012-01-01
The accurate measurement of ecosystem biomass is of great importance in scientific, resource management and energy sectors. In particular, biomass is a direct measurement of carbon storage within an ecosystem and of great importance for carbon cycle science and carbon emission mitigation. Remote Sensing is the most accurate tool for global biomass measurements because of the ability to measure large areas. Current biomass estimates are derived primarily from ground-based samples, as compiled and reported in inventories and ecosystem samples. By using remote sensing technologies, we are able to scale up the sample values and supply wall to wall mapping of biomass.
NASA Astrophysics Data System (ADS)
Dickinson, M. B.; Dietenberger, M.; Ellicott, E. A.; Hardy, C.; Hudak, A. T.; Kremens, R.; Mathews, W.; Schroeder, W.; Smith, A. M.; Strand, E. K.
2016-12-01
Few measurement techniques offer broad-scale insight on the extent and characteristics of biomass combustion during wildland fires. Remotely-sensed radiation is one of these techniques but its measurement suffers from several limitations and, when quantified, its use to derive variables of real interest depends on an understanding of the fire's mass and energy budget. In this talk, we will review certain assumptions of wildland fire radiation measurement and explore the use of those measurements to infer the fates of biomass and the dissipation of combustion energy. Recent measurements show that the perspective of the sensor (nadir vs oblique) matters relative to estimates of fire radiated power. Other considerations for producing accurate estimates of fire radiation from remote sensing include obscuration by an intervening forest canopy and to what extent measurements that are based on the assumption of graybody/blackbody behavior underestimate fire radiation. Fire radiation measurements are generally a means of quantifying other variables and are often not of interest in and of themselves. Use of fire radiation measurements as a means of inference currently relies on correlations with variables of interest such as biomass consumption and sensible and latent heat and emissions fluxes. Radiation is an imperfect basis for these correlations in that it accounts for a minority of combustion energy ( 15-30%) and is not a constant as is often assumed. Measurements suggest that fire convective energy accounts for the majority of combustion energy and (after radiation) is followed by latent energy, soil heating, and pyrolysis energy, more or less in that order. Combustion energy in and of itself is not its potential maximum, but is reduced to an effective heat of combustion by combustion inefficiency and by work done to pyrolyze fuel (important in char production) and in moisture vaporization. The effective heat of combustion is often on the order of 65% of its potential maximum. Through consideration of available data and modeling, we conclude that there is substantial scope to improve the science behind fire radiation measurements and the inferences derived from those measurements.
Kenneth L. Clark; Michael Gallagher; Warren E. Heilman; Nicholas Skowronski; Eric Mueller; Albert. Simeoni
2017-01-01
Fuel loading and consumption during prescribed fires are well-characterized for many pine-dominated forests, but relationships between firing practices, consumption of specific fuel components, and above-canopy turbulence and energy exchange have received less attention (Ottmar et al. 2016, Clements et al. 2016). However, quantitative information on how firing patterns...
Fire intensity, fire severity and burn severity: A brief review and suggested usage
Keeley, J.E.
2009-01-01
Several recent papers have suggested replacing the terminology of fire intensity and fire severity. Part of the problem with fire intensity is that it is sometimes used incorrectly to describe fire effects, when in fact it is justifiably restricted to measures of energy output. Increasingly, the term has created confusion because some authors have restricted its usage to a single measure of energy output referred to as fireline intensity. This metric is most useful in understanding fire behavior in forests, but is too narrow to fully capture the multitude of ways fire energy affects ecosystems. Fire intensity represents the energy released during various phases of a fire, and different metrics such as reaction intensity, fireline intensity, temperature, heating duration and radiant energy are useful for different purposes. Fire severity, and the related term burn severity, have created considerable confusion because of recent changes in their usage. Some authors have justified this by contending that fire severity is defined broadly as ecosystem impacts from fire and thus is open to individual interpretation. However, empirical studies have defined fire severity operationally as the loss of or change in organic matter aboveground and belowground, although the precise metric varies with management needs. Confusion arises because fire or burn severity is sometimes defined so that it also includes ecosystem responses. Ecosystem responses include soil erosion, vegetation regeneration, restoration of community structure, faunal recolonization, and a plethora of related response variables. Although some ecosystem responses are correlated with measures of fire or burn severity, many important ecosystem processes have either not been demonstrated to be predicted by severity indices or have been shown in some vegetation types to be unrelated to severity. This is a critical issue because fire or burn severity are readily measurable parameters, both on the ground and with remote sensing, yet ecosystem responses are of most interest to resource managers.
Error-eliminating rapid ultrasonic firing
Borenstein, Johann; Koren, Yoram
1993-08-24
A system for producing reliable navigation data for a mobile vehicle, such as a robot, combines multiple range samples to increase the "confidence" of the algorithm in the existence of an obstacle. At higher vehicle speed, it is crucial to sample each sensor quickly and repeatedly to gather multiple samples in time to avoid a collision. Erroneous data is rejected by delaying the issuance of an ultrasonic energy pulse by a predetermined wait-period, which may be different during alternate ultrasonic firing cycles. Consecutive readings are compared, and the corresponding data is rejected if the readings differ by more than a predetermined amount. The rejection rate for the data is monitored and the operating speed of the navigation system is reduced if the data rejection rate is increased. This is useful to distinguish and eliminate noise from the data which truly represents the existence of an article in the field of operation of the vehicle.
Error-eliminating rapid ultrasonic firing
Borenstein, J.; Koren, Y.
1993-08-24
A system for producing reliable navigation data for a mobile vehicle, such as a robot, combines multiple range samples to increase the confidence'' of the algorithm in the existence of an obstacle. At higher vehicle speed, it is crucial to sample each sensor quickly and repeatedly to gather multiple samples in time to avoid a collision. Erroneous data is rejected by delaying the issuance of an ultrasonic energy pulse by a predetermined wait-period, which may be different during alternate ultrasonic firing cycles. Consecutive readings are compared, and the corresponding data is rejected if the readings differ by more than a predetermined amount. The rejection rate for the data is monitored and the operating speed of the navigation system is reduced if the data rejection rate is increased. This is useful to distinguish and eliminate noise from the data which truly represents the existence of an article in the field of operation of the vehicle.
An operational system of fire danger rating over Mediterranean Europe
NASA Astrophysics Data System (ADS)
Pinto, Miguel M.; DaCamara, Carlos C.; Trigo, Isabel F.; Trigo, Ricardo M.
2017-04-01
A methodology is presented to assess fire danger based on the probability of exceedance of prescribed thresholds of daily released energy. The procedure is developed and tested over Mediterranean Europe, defined by latitude circles of 35 and 45°N and meridians of 10°W and 27.5°E, for the period 2010-2016. The procedure involves estimating the so-called static and daily probabilities of exceedance. For a given point, the static probability is estimated by the ratio of the number of daily fire occurrences releasing energy above a given threshold to the total number of occurrences inside a cell centred at the point. The daily probability of exceedance which takes into account meteorological factors by means of the Canadian Fire Weather Index (FWI) is in turn estimated based on a Generalized Pareto distribution with static probability and FWI as covariates of the scale parameter. The rationale of the procedure is that small fires, assessed by the static probability, have a weak dependence on weather, whereas the larger fires strongly depend on concurrent meteorological conditions. It is shown that observed frequencies of exceedance over the study area for the period 2010-2016 match with the estimated values of probability based on the developed models for static and daily probabilities of exceedance. Some (small) variability is however found between different years suggesting that refinements can be made in future works by using a larger sample to further increase the robustness of the method. The developed methodology presents the advantage of evaluating fire danger with the same criteria for all the study area, making it a good parameter to harmonize fire danger forecasts and forest management studies. Research was performed within the framework of EUMETSAT Satellite Application Facility for Land Surface Analysis (LSA SAF). Part of methods developed and results obtained are on the basis of the platform supported by The Navigator Company that is currently providing information about fire meteorological danger for Portugal for a wide range of users.
NASA Technical Reports Server (NTRS)
Roschke, E. J.; Coulbert, C. D.
1979-01-01
The five relative energy release criteria (RERC) which are a first step towards formulating a unified concept that can be applied to the development of fires in enclosures, place upper bounds on the rate and amount of energy released during a fire. They are independent, calculated readily, and may be applied generally to any enclosure regardless of size. They are useful in pretest planning and for interpreting experimental data. Data from several specific fire test programs were examined to evaluate the potential use of RERC to provide test planning guidelines. The RERC were compared with experimental data obtained in full-scale enclosures. These results confirm that in general the RERC do identify the proper limiting constraints on enclosure fire development and determine the bounds of the fire development envelope. Plotting actual fire data against the RERC reveals new valid insights into fire behavior and reveals the controlling constraints in fire development. The RERC were calculated and plotted for several descrpitions of full-scale fires in various aircraft compartments.
Han, Fang; Wang, Zhijie; Fan, Hong
2017-01-01
This paper proposed a new method to determine the neuronal tuning curves for maximum information efficiency by computing the optimum firing rate distribution. Firstly, we proposed a general definition for the information efficiency, which is relevant to mutual information and neuronal energy consumption. The energy consumption is composed of two parts: neuronal basic energy consumption and neuronal spike emission energy consumption. A parameter to model the relative importance of energy consumption is introduced in the definition of the information efficiency. Then, we designed a combination of exponential functions to describe the optimum firing rate distribution based on the analysis of the dependency of the mutual information and the energy consumption on the shape of the functions of the firing rate distributions. Furthermore, we developed a rapid algorithm to search the parameter values of the optimum firing rate distribution function. Finally, we found with the rapid algorithm that a combination of two different exponential functions with two free parameters can describe the optimum firing rate distribution accurately. We also found that if the energy consumption is relatively unimportant (important) compared to the mutual information or the neuronal basic energy consumption is relatively large (small), the curve of the optimum firing rate distribution will be relatively flat (steep), and the corresponding optimum tuning curve exhibits a form of sigmoid if the stimuli distribution is normal. PMID:28270760
Fire-protection research for energy technology: Fy 80 year end report
NASA Astrophysics Data System (ADS)
Hasegawa, H. K.; Alvares, N. J.; Lipska, A. E.; Ford, H.; Priante, S.; Beason, D. G.
1981-05-01
This continuing research program was initiated in order to advance fire protection strategies for Fusion Energy Experiments (FEE). The program expanded to encompass other forms of energy research. Accomplishments for fiscal year 1980 were: finalization of the fault-free analysis of the Shiva fire management system; development of a second-generation, fire-growth analysis using an alternate model and new LLNL combustion dynamics data; improvements of techniques for chemical smoke aerosol analysis; development and test of a simple method to assess the corrosive potential of smoke aerosols; development of an initial aerosol dilution system; completion of primary small-scale tests for measurements of the dynamics of cable fires; finalization of primary survey format for non-LLNL energy technology facilities; and studies of fire dynamics and aerosol production from electrical insulation and computer tape cassettes.
10 CFR 36.27 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Fire protection. 36.27 Section 36.27 Energy NUCLEAR... Requirements for Irradiators § 36.27 Fire protection. (a) The radiation room at a panoramic irradiator must... become fully shielded if a fire is detected. (b) The radiation room at a panoramic irradiator must be...
Individual Aerosol Particle Types Produced by Savanna Burning
NASA Astrophysics Data System (ADS)
Posfai, M.; Simonics, R.; Li, J.; Hobbs, P. V.; Buseck, P. R.; Buseck, P. R.
2001-12-01
We used analytical transmission electron microscopy (TEM) to study individual aerosol particles that were collected on the University of Washington Convair-580 research aircraft over southern Africa during the Safari2000 Dry Season Experiment. Our goals were to study the compositions, morphologies, and mixing states of carbonaceous particles, in order to better understand the physical and chemical properties of biomass smoke on the individual-particle level. The compositions of single particles were determined using energy-dispersive x-ray spectrometry (EDS) and electron energy-loss spectroscopy (EELS). Energy-loss maps obtained with the TEM are useful for studying the spatial distribution of light elements such as carbon within the particles; thus, they provide a detailed picture of complex particles. Carbonaceous particles were assigned into three main groups on the basis of morphology and composition: "organic particles with inorganic inclusions," "tar balls," and "soot." Soot is recognized by its characteristic morphology and microstructure. The distinction between "organic particles with inorganic inclusions" and "tar balls" is somewhat arbitrary, since the two criteria that are used for their distinction (composition and aspect ratio) change continually. The relative concentrations of the three major particle types vary with the type of fire and distance from fire. In the plume of a smoldering fire west of Beria (August 31) the relative concentration of tar balls increased with aging of the plume. Tar balls have a fairly narrow size distribution with a maximum between 100 and 200 nm (diameter). The inorganic K-salt inclusions (KCl, K2SO4, KNO3) within "organic particles" should make these particles hygroscopic, regardless of the properties of the organic compounds. Aging causes the conversion of KCl into K2SO4, KNO3. Aerosol production from flaming and smoldering fires was compared over Kruger National Park on August 17; more soot and more Cl-rich inclusions in organic particles were produced by the flaming fire than by the smoldering fire. Further sets of samples from other flights of Safari2000 are being studied.
C. Klauberg; A. T. Hudak; B. C. Bright; L. Boschetti; M. B. Dickinson; R. L. Kremens; C. A. Silva
2018-01-01
Fire radiative energy density (FRED, J m-2) integrated from fire radiative power density (FRPD, W m-2) observations of landscape-level fires can present an undersampling problem when collected from fixed-wing aircraft. In the present study, the aircraft made multiple passes over the fire at ~3 min intervals, thus failing to observe most of the FRPD emitted as the flame...
Use of intumescent compounds in fire curtains
NASA Astrophysics Data System (ADS)
Nedryshkin, Oleg; Gravit, Marina; Mukhamedzhanova, Olga
2017-10-01
Automatic fire curtains are designed to divide sections of premises and structures into fire compartments for the purpose of localizing a fire, as well as filling openings in fire barriers. If a fire occurs due to a signal from a fire alarm sensor or a signal from a fire station, the blind automatically falls and locates the source of ignition. The paper presents the results of testing nine samples of fire curtains with an applied intumescent composition. Tests were conducted for 60 minutes before loss of sample integrity. The average temperature from the heated side of the sample reached 800 ∼ 1000 ° C. Depending on the sample, the temperature from the unheated side ranged from 70 ° C to 294 ° C. The best result was shown by a sample from a layer of needle-punched heat-insulating material with a thermal conductivity of 0.036 W/(m×K) placed between layers of foil and treated with water-based intumescent composition of silica material.
Evaluation of sampling strategies to estimate crown biomass
Krishna P Poudel; Hailemariam Temesgen; Andrew N Gray
2015-01-01
Depending on tree and site characteristics crown biomass accounts for a significant portion of the total aboveground biomass in the tree. Crown biomass estimation is useful for different purposes including evaluating the economic feasibility of crown utilization for energy production or forest products, fuel load assessments and fire management strategies, and wildfire...
Patrick H. Freeborn; Martin J. Wooster; Wei Min Hao; Cecily A. Nordgren Ryan; Stephen P. Baker; Charles Ichoku
2008-01-01
Forty-four small-scale experimental fires were conducted in a combustion chamber to examine the relationship between biomass consumption, smoke production, convective energy release, and middle infrared (MIR) measurements of fire radiative energy (FRE). Fuel bed weights, trace gas and aerosol particle concentrations, stack flow rate and temperature, and concurrent...
NASA Astrophysics Data System (ADS)
Dickinson, M.; Kremens, R.; Bova, A. S.
2012-12-01
Closing the wildland fire heat budget involves characterizing the heat source and energy dissipation across the range of variability in fuels and fire behavior. Meeting this challenge will lay the foundation for predicting direct ecological effects of fires and fire-atmosphere coupling. Here, we focus on the relationships between the fire radiation field, as measured from the zenith, fuel consumption, and the behavior of spreading flame fronts. Experiments were conducted in 8 m x 8 m outdoor plots using pre-conditioned wildland fuels characteristic of mixed-oak forests of the eastern United States. Using dual-band radiometers with a field of view of about 18.5 m^2 at a height of 4.2 m, we found a near-linear increase in fire radiative energy density (FRED) over a range of fuel consumption between 0.15 kg m^-2 to 3.25 kg m^-2. Using an integrated heat budget, we estimate that the fraction of total theoretical combustion energy density radiated from the plot averaged 0.17, the fraction of latent energy transported in the plume averaged 0.08, and the fraction accounted for by the combination of fire convective energy transport and soil heating averaged 0.72. Future work will require, at minimum, instantaneous and time-integrated estimates of energy transported by radiation, convection, and soil heating across a range of fuels. We introduce the Rx-CADRE project through which such measurements are being made.
NASA Astrophysics Data System (ADS)
Choi, Soojin; Yoh, Jack J.
2017-08-01
The possibility verification of the first attempt to apply LIBS to arson investigation was performed. LIBS has capabilities for real time in-situ analysis and depth profiling. It can provide valuable information about the fire debris that are complementary to the classification of original sample components and combustion residues. In this study, fire debris was analyzed to determine the ignition source and existence of a fire accelerant using LIBS spectra and depth profiling analysis. Fire debris chemical composition and carbon layer thickness determines the possible ignition source while the carbon layer thickness of combusted samples represents the degree of sample carbonization. When a sample is combusted with fire accelerants, a thicker carbon layer is formed because the burning rate is increased. Therefore, depth profiling can confirm the existence of combustion accelerants, which is evidence of arson. Also investigation of fire debris by depth profiling is still possible when a fire is extinguished with water from fire hose. Such data analysis and in-situ detection of forensic signals via the LIBS may assist fire investigation at crime scenes.
AmeriFlux US-An3 Anaktuvuk River Unburned
Hobbie, John [Marine Biological Laboratory; Rocha, Adrian [Marine Biological Laboratory; Shaver, Gaius [Marine Biological Laboratory
2016-01-01
This is the AmeriFlux version of the carbon flux data for the site US-An3 Anaktuvuk River Unburned. Site Description - The Anaktuvuk River fire on the North Slope of Alaska started on July 16, 2007 by lightning. It continued until the end of September when nearby lakes had already frozen over and burned >256,000 acres, creating a mosaic of patches that differed in burn severity. The Anaktuvuk River Severe Burn, Moderate Burn, and Unburned sites are 40 km to the west of the nearest road and were selected in late May 2008 to determine the effects of the fire on carbon, water, and energy exchanges during the growing season. Because the fire had burned through September of the previous year, initial deployment of flux towers occurred prior to any significant vegetative regrowth, and our sampling campaign captured the full growing season in 2008. The Unburned site was located in a large area of tundra that was unaffected by the fire.
Climatic variability of a fire-weather index based on turbulent kinetic energy and the Haines Index
Warren E. Heilman; Xindi Bian
2010-01-01
Combining the Haines Index (HI) with near-surface turbulent kinetic energy (TKEs) through a product of the two values (HITKEs) has shown promise as an indicator of the atmospheric potential for extreme and erratic fire behavior in the U.S. Numerical simulations of fire-weather evolution during past wildland fire episodes in...
NASA Astrophysics Data System (ADS)
Matosziuk, L.; Gallo, A.; Hatten, J. A.; Heckman, K. A.; Nave, L. E.; Sanclements, M.; Strahm, B. D.; Weiglein, T.
2017-12-01
Wildfire can dramatically affect the quantity and quality of soil organic matter (SOM), producing thermally altered organic material such as pyrogenic carbon (PyC) and polyaromatic hydrocarbons (PAHs). The movement of this thermally altered material through terrestrial and aquatic ecosystems can differ from that of unburned SOM, with far-reaching consequences for soil carbon cycling and water quality. Unfortunately, due to the rapid ecological changes following fire and the lack of robust pre-fire controls, the cycling of fire-altered carbon is still poorly understood. In December 2016, the Chimney Tops 2 fire in Great Smoky Mountains National Park burned over co-located terrestrial and aquatic NEON sites. We have leveraged the wealth of pre-fire data at these sites (chemical, physical, and microbial characterization of soils, continuous measurements of both soil and stream samples, and five soil cores up to 110 cm in depth) to conduct a thorough study of the movement of fire-altered organic matter through terrestrial and aquatic ecosystems. Stream samples have been collected weekly beginning 5 weeks post-fire. Grab samples of soil were taken at discrete time points in the first two months after the fire. Eight weeks post-fire, a second set of cores was taken and resin lysimeters installed at three different depths. A third set of cores and grab samples will be taken 8-12 months after the fire. In addition to routine soil characterization techniques, solid samples from cores and grab samples at all time points will be analyzed for PyC and PAHs. To determine the effect of fire on dissolved organic matter (DOM), hot water extracts of these soil samples, as well as the stream samples and lysimeter samples, will also be analyzed for PyC and PAHs. Selected samples will be analyzed by 1D- and 2D-NMR to further characterize the chemical composition of DOM. This extensive investigation of the quantity and quality of fire-altered organic material at discrete time points will provide insight into the production and cycling of thermally-altered SOM and DOM. We hypothesize that PyC will be an important source of SOM to surface mineral soil horizons, and that the quantity of DOM will increase after fire, providing a rapid pulse of C to deep soils and aquatic systems.
[Analysis of human tissue samples for volatile fire accelerants].
Treibs, Rudolf
2014-01-01
In police investigations of fires, the cause of a fire and the fire debris analysis regarding traces of fire accelerants are important aspects for forensic scientists. Established analytical procedures were recently applied to the remains of fire victims. When examining lung tissue samples, vapors inhaled from volatile ignitable liquids could be identified and differentiated from products of pyrolysis caused by the fire. In addition to the medico-legal results this evidence allowed to draw conclusions as to whether the fire victim was still alive when the fire started.
NASA Astrophysics Data System (ADS)
Kataria, V.; Mehta, D. S.
2018-04-01
Erbium (Er3+)-ytterbium (Yb3+) doped gadolinium oxysulphide (Gd2O2S) phosphor has been developed via a facile method of solid-state flux fusion, and offers two-fold spectrum modification with highly intense Stokes and anti-Stokes shift. The effect of the firing cycle on the photoluminescent response and morphology of Gd2O2S:Er,Yb is scrutinized, wherein the firing temperature was varied (1000 °C-1250 °C), keeping firing time and all other parameters constant. Interestingly, the nanostructures fired below 1150 °C showed nanorods of diameter ~200 nm and length ~1-2 µm, whereas firing at 1150 °C and above rendered nanospheres with small diameter, ~350 nm. Highly bright upconversion (UC) emission was achieved even under an extremely low excitation power density of 800 µW cm-2 from a 980 nm laser, and was comfortably visible to the naked eye. The incident power dependent studies disclosed increase in UC-emission intensity with increasing excitation power and a quasi-linear dependence on excitation power density. Intense characteristic UC-emission of Er3+ excited states at 525 nm, 556 nm and 668 nm were observed, and the green emission band was found to be dominant over the red band in intensity. Concurrently, downconversion (DC) emission at 556 nm and 669 nm was also exhibited under ultraviolet excitation (285 nm and 380 nm), with the red band being more powerful than the green, unlike UC-emission. Firing temperature dependent studies divulged the dependence of luminescence intensity on the firing cycle of the luminophore and formation of the respective luminescent phase. The UC-emission intensity was found to be maximum for samples fired at 1150 °C, whereas samples fired at 1000 °C showed the highest DC-emission intensity. The excitation and emission profile of single Gd2O2S:Er,Yb phosphor lying in the desired spectral region and as a dual spectral converter marks its possible application for enhanced harvesting of sunlight.
Mutagenicity in emissions from coal- and oil-fired boilers.
Alfheim, I; Bergström, J G; Jenssen, D; Møller, M
1983-01-01
The mutagenicity of emission samples from three oil-fired and four coal-fired boilers have been compared by using the Salmonella/microsome assay. Very little or no mutagenic activity was observed in samples from five of these boilers. The sample from one oil-fired boiler showed mutagenic activity of about 500 revertants/MJ, and the sample from a coal-fired fluidized bed combustor had an activity of 58,000 revertants/MJ measured with strain TA 98 in the absence of metabolic activation. All samples contained substances that were cytotoxic to the test bacteria, thus making it difficult to obtain linear dose-response curves. Mutagenic activity at low levels may remain undetected due to this toxicity of the samples. Samples with mutagenic activity below the detection limit in the Salmonella test have also been tested for forward mutations at the HGPRT locus in V79 hamster cells. Weak mutagenic effects were detected in two of the samples, whereas the sample from one oil-fired boiler remained negative. In this test, as well as in the Salmonella test, a strong cytotoxic effect could be observed with all samples. PMID:6825617
SCAR-B fires in the tropics: Properties and remote sensing from EOS-MODIS
NASA Astrophysics Data System (ADS)
Kaufman, Yoram J.; Kleidman, Richard G.; King, Michael D.
1998-12-01
Two moderate resolution imaging spectroradiometer (MODIS) instruments are planned for launch in 1999 and 2000 on the NASA Earth Observing System (EOS) AM-1 and EOS PM-1 satellites. The MODIS instrument will sense fires with designated 3.9 and 11 μm channels that saturate at high temperatures (450 and 400 K, respectively). MODIS data will be used to detect fires, to estimate the rate of emission of radiative energy from the fire, and to estimate the fraction of biomass burned in the smoldering phase. The rate of emission of radiative energy is a measure of the rate of combustion of biomass in the fires. In the Smoke, Clouds, and Radiation-Brazil (SCAR-B) experiment the NASA ER-2 aircraft flew the MODIS airborne simulator (MAS) to measure the fire thermal and mid-IR signature with a 50 m spatial resolution. These data are used to observe the thermal properties and sizes of fires in the cerrado grassland and Amazon forests of Brazil and to simulate the performance of the MODIS 1 km resolution fire observations. Although some fires saturated the MAS 3.9 μm channel, all the fires were well within the MODIS instrument saturation levels. Analysis of MAS data over different ecosystems, shows that the fire size varied from single MAS pixels (50×50 m) to over 1 km2. The 1×1 km resolution MODIS instrument can observe only 30-40% of these fires, but the observed fires are responsible for 80 to nearly 100% of the emitted radiative energy and therefore for 80 to 100% of the rate of biomass burning in the region. The rate of emission of radiative energy from the fires correlated very well with the formation of fire burn scars (correlation coefficient = 0.97). This new remotely sensed quantity should be useful in regional estimates of biomass consumption.
Chen, Bingyu; Liu, Guijian; Sun, Ruoyu
2016-05-01
A better understanding on the partitioning behavior of mercury (Hg) during coal combustion in large-scale coal-fired power plants is fundamental for drafting Hg-emission control regulations. Two large coal-fired utility boilers, equipped with electrostatic precipitators (ESPs) and a wet flue gas desulfurization (WFGD) system, respectively, in coal energy-dominant Huainan City, China, were selected to investigate the distribution and fate of Hg during coal combustion. In three sampling campaigns, we found that Hg in bottom ash was severely depleted with a relative enrichment (RE) index <7 %, whereas the RE index for fly ash (9-54%) was comparatively higher and variable. Extremely high Hg was concentrated in gypsum (≤4500 ng/g), which is produced in the WFGD system. Mass balance calculation shows that the shares of Hg in bottom ash, fly ash, WFGD products (gypsum, effluents, sludge), and stack emissions were <2, 17-32, 7-22, and 54-82%, respectively. The Hg-removal efficiencies of ESPs, WFGD, and ESPs + WFGD were 17-32, 10-29, and 36-46%, respectively. The Hg-emission factor of studied boilers was in a high range of 0.24-0.29 g Hg/t coal. We estimated that Hg emissions in all Huainan coal-fired power plants varied from 1.8 Mg in 2003 to 7.3 Mg in 2010.
NASA Astrophysics Data System (ADS)
Li, Fang; Lawrence, David M.; Bond-Lamberty, Ben
2017-04-01
Fire is a global phenomenon and tightly interacts with the biosphere and climate. This study provides the first quantitative assessment and understanding of fire’s influence on the global annual land surface air temperature and energy budget through its impact on terrestrial ecosystems. Fire impacts are quantified by comparing fire-on and fire-off simulations with the Community Earth System Model (CESM). Results show that, for the 20th century average, fire-induced changes in terrestrial ecosystems significantly increase global land annual mean surface air temperature by 0.18 °C, decrease surface net radiation and latent heat flux by 1.08 W m-2 and 0.99 W m-2, respectively, and have limited influence on sensible heat flux (-0.11 W m-2) and ground heat flux (+0.02 W m-2). Fire impacts are most clearly seen in the tropical savannas. Our analyses suggest that fire increases surface air temperature predominantly by reducing latent heat flux, mainly due to fire-induced damage to the vegetation canopy, and decreases net radiation primarily because fire-induced surface warming significantly increases upward surface longwave radiation. This study provides an integrated estimate of fire and induced changes in ecosystems, climate, and energy budget at a global scale, and emphasizes the importance of a consistent and integrated understanding of fire effects.
David J. Ganz; David S. Saah; Klaus Barber; Mark Nechodom
2007-01-01
The fire behavior modeling described here, conducted as part of the Biomass to Energy (B2E) life cycle assessment, is funded by the California Energy Commission to evaluate the potential net benefits associated with treating and utilizing forest biomass. The B2E project facilitates economic, environmental, energy, and effectiveness assessments of the potential public...
Radiant energy dosimeter for field use
A. Broido; A.W. McMasters
1967-01-01
Thermal radiation measurements in Project Flambeau fires involved a limited number of conventional radiometers located outside the fire periphery. A simple, cheap, easily-fabricated, light-weight, self-contained, rugged dosimeter was desired to withstand a hot fire environment, including a specific energy input of 5,000 cal cm -2, and to record...
NASA Technical Reports Server (NTRS)
Juarez, Alfredo; Harper, Susan A.; Hirsch, David B.; Carriere, Thierry
2013-01-01
Many sources of fuel are present aboard current spacecraft, with one especially hazardous source of stored energy: lithium ion batteries. Lithium ion batteries are a very hazardous form of fuel due to their self-sustaining combustion once ignited, for example, by an external heat source. Batteries can become extremely energetic fire sources due to their high density electrochemical energy content that may, under duress, be violently converted to thermal energy and fire in the form of a thermal runaway. Currently, lithium ion batteries are the preferred types of batteries aboard international spacecraft and therefore are routinely installed, collectively forming a potentially devastating fire threat to a spacecraft and its crew. Currently NASA is developing a fine water mist portable fire extinguisher for future use on international spacecraft. As its development ensues, a need for the standard evaluation of various types of fire extinguishers against this potential threat is required to provide an unbiased means of comparing between fire extinguisher technologies and ranking them based on performance.
NASA Technical Reports Server (NTRS)
Coulbert, C. D.
1978-01-01
A method for predicting the probable course of fire development in an enclosure is presented. This fire modeling approach uses a graphic plot of five fire development constraints, the relative energy release criteria (RERC), to bound the heat release rates in an enclosure as a function of time. The five RERC are flame spread rate, fuel surface area, ventilation, enclosure volume, and total fuel load. They may be calculated versus time based on the specified or empirical conditions describing the specific enclosure, the fuel type and load, and the ventilation. The calculation of these five criteria, using the common basis of energy release rates versus time, provides a unifying framework for the utilization of available experimental data from all phases of fire development. The plot of these criteria reveals the probable fire development envelope and indicates which fire constraint will be controlling during a criteria time period. Examples of RERC application to fire characterization and control and to hazard analysis are presented along with recommendations for the further development of the concept.
Joseph J. O' Brien; E. Louise Loudermilk; J. Kevin Hiers; Scott Pokswinski; Benjamin Hornsby; Andrew Hudak; Dexter Strother; Eric Rowell; Benjamin C. Bright
2016-01-01
Wildland fire radiant energy emission is one of the only measurements of combustion that can be made at high temporal and spatial resolutions. Furthermore, spatially and temporally explicit measurements are critical for making inferences about ecological fire effects. Although the correlation between fire frequency and plant biological diversity in frequently burned ...
RDF (Refuse Derived Fuel) Utilization in a Navy Stoker Coal-Fired Boiler.
1984-10-01
the energy production in any coal-fired boiler conversion consideration. The selection of the actual RDF to be used in a converted boiler should be... industrial boilers by gathering information from the Navy Energy and Environmental Support Activity, engineering field divi- sions, and field...activities. Currently the Navy has 27 industrial size boilers firing coal as a primary fuel and 10 firing coal as a secondary fuel. The four principal factors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cary, Robert
The purpose of this study was to measure the organic carbon (OC) and elemental carbon (EC) fractions of PM2.5 particulate matter at the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains (SGP) sampling site for a 6-month period during the summer of 2013. The site is in a rural location remote from any populated areas, so it would be expected to reflect carbon concentration over long-distance transport patterns. During the same period in 2012, a number of prairie fires in Oklahoma and Texas had produced large plumes of smoke particles, but OC andmore » EC particles had not been quantified. In addition, during the summer months, other wild fires, such as forest fires in the Rocky Mountain states and other areas, can produce carbon aerosols that are transported over long distances. Both of these source types would be expected to contain mixtures of both OC and EC.« less
Thermal Pretreatment of Wood for Co-gasification/co-firing of Biomass and Coal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Ping; Howard, Bret; Hedges, Sheila
2013-10-29
Utilization of biomass as a co-feed in coal and biomass co-firing and co-gasification requires size reduction of the biomass. Reducing biomass to below 0.2 mm without pretreatment is difficult and costly because biomass is fibrous and compressible. Torrefaction is a promising thermal pretreatment process and has the advantages of increasing energy density, improving grindability, producing fuels with more homogenous compositions and hydrophobic behavior. Temperature is the most important factor for the torrefaction process. Biomass grindability is related to cell wall structure, thickness and composition. Thermal treatment such as torrefaction can cause chemical changes that significantly affect the strength of biomass.more » The objectives of this study are to understand the mechanism by which torrefaction improves the grindability of biomass and discuss suitable temperatures for thermal pretreatment for co-gasification/co-firing of biomass and coal. Wild cherry wood was selected as the model for this study. Samples were prepared by sawing a single tangential section from the heartwood and cutting it into eleven pieces. The samples were consecutively heated at 220, 260, 300, 350, 450 and 550⁰C for 0.5 hr under flowing nitrogen in a tube furnace. Untreated and treated samples were characterized for physical properties (color, dimensions and weight), microstructural changes by SEM, and cell wall composition changes and thermal behaviors by TGA and DSC. The morphology of the wood remained intact through the treatment range but the cell walls were thinner. Thermal treatments were observed to decompose the cell wall components. Hemicellulose decomposed over the range of ~200 to 300⁰C and resulted in weakening of the cell walls and subsequently improved grindability. Furthermore, wood samples treated above 300⁰C lost more than 39% in mass. Therefore, thermal pretreatment above the hemicelluloses decomposition temperature but below 300⁰C is probably sufficient to improve grindability and retain energy value.« less
High Temperature Behavior of Cr3C2-NiCr Coatings in the Actual Coal-Fired Boiler Environment
NASA Astrophysics Data System (ADS)
Bhatia, Rakesh; Sidhu, Hazoor Singh; Sidhu, Buta Singh
2015-03-01
Erosion-corrosion is a serious problem observed in steam-powered electricity generation plants, and industrial waste incinerators. In the present study, four compositions of Cr3C2-(Ni-20Cr) alloy coating powder were deposited by high-velocity oxy-fuel spray technique on T-91 boiler tube steel. The cyclic studies were performed in a coal-fired boiler at 1123 K ± 10 K (850 °C ± 10 °C). X-ray diffraction, scanning electron microscopy/energy dispersive X-ray analysis and elemental mapping analysis techniques were used to analyze the corrosion products. All the coatings deposited on T-91 boiler tube steel imparted hot corrosion resistance. The 65 pctCr3C2 -35 pct (Ni-20Cr)-coated T-91 steel sample performed better than all other coated samples in the given environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castaldini, C.; Waterland, L.R.
1987-03-01
The two-volume report gives results from field tests of a wood-waste-fired industrial watertube boiler. Two series of tests were performed: one firing dry (11% moisture) wood waste, and the other firing green (34% moisture) wood waste. Emission measurements included: continuous monitoring of flue-gas emissions; source-assessment sampling system (SASS) sampling of the flue gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semi-volatile organic priority pollutants, and flue-gas concentrations of 73 trace elements; Method 5 sampling for particulate; controlled condensation system sampling for SO/submore » 2/ and SO/sub 3/; and grab sampling of boiler mechanical collector hopper ash for inorganic composition determinations. Total organic emissions decreased from 60-135 mg/dscm firing dry wood to 2-65 mg/dscm firing green wood, in parallel with corresponding boiler CO emissions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castaldini, C.; Waterland, L.R.
1987-03-01
The two-volume report gives results from field tests of a wood-waste-fired industrial watertube boiler. Two series of tests were performed: one firing dry (11% moisture) wood waste, and the other firing green (34% moisture) wood waste. Emission measurements included: continuous monitoring of flue-gas emissions; source-assessment sampling system (SASS) sampling of the flue-gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semi-volatile organic priority pollutants, and flue gas concentrations of 73 trace elements; Method 5 sampling for particulate; controlled condensation system sampling for SO/submore » 2/ and SO/sub 3/; and grab sampling of boiler mechanical collector hopper ash for inorganic and organic composition determinations. Total organic emissions decreased from 60-135 mg/dscm firing dry wood to 2-65 mg/dscm firing green wood, in parallel with corresponding boiler CO emissions.« less
Characterization of convective heating in full scale wildland fires
Bret Butler
2010-01-01
Data collected in the International Crown Fire modeling Experiment during 1999 are evaluated to characterize the magnitude and duration of convective energy heating in full scale crown fires. To accomplish this objective data on total and radiant incident heat flux, air temperature, and horizontal and vertical gas velocities were evaluated. Total and radiant energy...
A portable system for characterizing wildland fire behavior
Bret Butler; D. Jimenez; J. Forthofer; K. Shannon; Paul Sopko
2010-01-01
A field deployable system for quantifying energy and mass transport in wildland fires is described. The system consists of two enclosures: The first is a sensor/data logger combination package that allows characterization of convective/radiant energy transport in fires. This package contains batteries, a programmable data logger, sensors, and other electronics. The...
Fire danger rating over Mediterranean Europe based on fire radiative power derived from Meteosat
NASA Astrophysics Data System (ADS)
Pinto, Miguel M.; DaCamara, Carlos C.; Trigo, Isabel F.; Trigo, Ricardo M.; Feridun Turkman, K.
2018-02-01
We present a procedure that allows the operational generation of daily forecasts of fire danger over Mediterranean Europe. The procedure combines historical information about radiative energy released by fire events with daily meteorological forecasts, as provided by the Satellite Application Facility for Land Surface Analysis (LSA SAF) and the European Centre for Medium-Range Weather Forecasts (ECMWF). Fire danger is estimated based on daily probabilities of exceedance of daily energy released by fires occurring at the pixel level. Daily probability considers meteorological factors by means of the Canadian Fire Weather Index (FWI) and is estimated using a daily model based on a generalized Pareto distribution. Five classes of fire danger are then associated with daily probability estimated by the daily model. The model is calibrated using 13 years of data (2004-2016) and validated against the period of January-September 2017. Results obtained show that about 72 % of events releasing daily energy above 10 000 GJ belong to the extreme
class of fire danger, a considerably high fraction that is more than 1.5 times the values obtained when using the currently operational Fire Danger Forecast module of the European Forest Fire Information System (EFFIS) or the Fire Risk Map (FRM) product disseminated by the LSA SAF. Besides assisting in wildfire management, the procedure is expected to help in decision making on prescribed burning within the framework of agricultural and forest management practices.
Presciutti, Federica; Capitani, Donatella; Sgamellotti, Antonio; Brunetti, Brunetto Giovanni; Costantino, Ferdinando; Viel, Stéphane; Segre, Annalaura
2005-12-01
The aim of this study is to clarify the structure of an iron-rich clay and the structural changes involved in the firing process as a preliminary step to get information on ancient ceramic technology. To this purpose, illite-rich clay samples fired at different temperatures were characterized using a multitechnique approach, i.e., by electron paramagnetic resonance, scanning electron microscopy with electron dispersion X-ray spectrometry, X-ray powder diffraction, magic angle spinning and multiple quantum magic angle spinning NMR. During firing, four main reaction processes occur: dehydration, dehydroxylation, structural breakdown, and recrystallization. When the results are combined from all characterization methods, the following conclusions could be obtained. Interlayer H2O is located close to aluminum in octahedral sites and is driven off at temperatures lower than 600 degrees C. Between 600 and 700 degrees C dehydroxylation occurs whereas, between 800 and 900 degrees C, the aluminum in octahedral sites disappears, due to the breakdown of the illite structure, and all iron present is oxidized to Fe3+. In samples fired at 1000 and 1100 degrees C iron clustering was observed as well as large single crystals of iron with the occurrence of ferro- or ferrimagnetic effects. Below 900 degrees C the aluminum in octahedral sites presents a continuous distribution of chemical shift, suggesting the presence of slightly distorted sites. Finally, over the whole temperature range, the presence of at least two tetrahedral aluminum sites was revealed, characterized by different values of the quadrupolar coupling constant.
NASA Astrophysics Data System (ADS)
Li, F.; Lawrence, D. M.; Bond-Lamberty, B. P.; Levis, S.
2016-12-01
Fire is an integral Earth system process and the primary form of terrestrial ecosystem disturbance on a global scale. Here we provide the first quantitative assessment and understanding on fire's impact on global land carbon, water, and energy budgets and climate through changing ecosystems. This is done by quantifying the difference between 20th century fire-on and fire-off simulations using the Community Earth System Model (CESM1.2). Results show that fire decreases the net carbon gain of global terrestrial ecosystems by 1.0 Pg C/yr averaged across the 20th century, as a result of biomass and peat burning (1.9 Pg C/yr) partly offset by changing gross primary productivity, respiration, and land-use carbon loss (-0.9 Pg C/yr). In addition, fire's effect on global carbon budget intensifies with time. Fire significantly reduces land evapotranspiration (ET) by 600 km3/yr and increases runoff, but has limited impact on precipitation. The impact on ET and runoff is most clearly seen in the tropical savannas, African rainforest, and some boreal and Southern Asian forests mainly due to fire-induced reduction in the vegetation canopy. It also weakens both the significant upward trend in global land ET prior to the 1950s and the downward trend from 1950 to 1985 by 35%. Fire-induced changes in land ecosystems affects global energy budgets by significantly reducing latent heating and surface net radiation. Fire changes surface radiative budget dominantly by raising surface upward longwave radiation and net longwave radiation. It also increases the global land average surface air temperature (Tas) by 0.04°C, and significantly increases wind speed and decreases surface relative humidity. The fire-induced change in wind speed, Tas, and relative humidity implies a positive feedback loop between fire and climate. Moreover, fire-induced changes in land ecosystems contribute 20% of strong global land warming during 1910-1940, which provides a new mechanism for the early 20th century global land warming. The results emphasize the importance of fire disturbance in the Earth's carbon, water, and energy cycles and climate by changing terrestrial ecosystems.
Support Services for Ceramic Fiber-Ceramic Matrix Composites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurley, JP
2001-08-16
To increase national energy self-sufficiency for the near future, power systems will be required to fire low-grade fuels more efficiently than is currently possible. The typical coal-fired steam cycle used at present is limited to a maximum steam temperature of 540 C and a conversion efficiency of 35%. Higher working-fluid temperatures are required to boost efficiency, exposing subsystems to very damaging conditions. Issues of special concern to materials developers are corrosion and warping of hot-gas particulate filters and corrosion and erosion of high-temperature heat exchangers. The University of North Dakota Energy and Environmental Research Center (EERC) is working with themore » National Energy Technology Laboratory in conjunction with NCC Engineering, Inc., to provide technical assistance and coal by-products to the Fossil Energy Materials Advanced Research and Technology Development Materials Program investigating materials failure in fossil energy systems. The main activities of the EERC are to assemble coal slag and hot-gas filter ash samples for use by materials researchers, to assist in providing opportunities for realistic tests of advanced materials in pilot-scale fossil energy systems, and to provide analytical support in determining corrosion mechanisms of the exposed materials. In this final report for the project year of September 2000 through August 2001, the facilities at the EERC that can be used by researchers for realistic testing of materials are described. Researchers can include sample coupons in each of these facilities at no cost since they are being operated under separate funding. In addition, two pilot-scale coal combustion tests are described in which material sample coupons were included from researchers involved in the development of fossil energy materials. The results of scanning electron microscopy (SEM) energy dispersive x-ray analyses of the corrosion products and interactions between the surface scales of the coupons and the products of coal combustion found on the coupons exposed during those tests are reported. Finally, a relative comparison of ceramic and alloy material performance based on the SEM results is presented.« less
Bricks in historical buildings of Toledo City: characterisation and restoration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopez-Arce, Paula; Garcia-Guinea, Javier; Gracia, Mercedes
2003-01-15
Two different types of ancient bricks (12th to 14th centuries) collected from historical buildings of Toledo (Spain) were characterised by optical microscopy, scanning electron microscopy/energy-dispersive X-ray spectrometers (SEM/EDS), electron probe microanalysis (EM), X-ray diffraction (XRD), differential thermal analysis (DTA) and {sup 57}Fe-Moessbauer spectroscopy. Physical properties such as water absorption and suction, porosity, density and compression strength were also determined. Several minerals found in the brick matrix, such as garnet, let us infer raw material sources; calcite, dolomite, illite and neoformed gehlenite and diopside phases, on temperature reached in firing; secondary calcite, on first cooling scenarios; and manganese micronodules, on latemore » pollution environments. XRD and DTA of original and refired samples supply information about firing temperatures. Additional data on firing conditions and type of the original clay are provided by the Moessbauer study. Physical properties of both types of bricks were compared and correlated with raw materials and fabric and firing technology employed. The physicochemical characterisation of these bricks provides valuable data for restoration purposes to formulate new specific bricks using neighbouring raw materials.« less
Özkan, İlker; Yayla, Zeliha
2016-03-01
The aim of this study is to establish a correlation between physical properties and ultrasonic pulse velocity of clay samples fired at elevated temperatures. Brick-making clay and pottery clay were studied for this purpose. The physical properties of clay samples were assessed after firing pressed clay samples separately at temperatures of 850, 900, 950, 1000, 1050 and 1100 °C. A commercial ultrasonic testing instrument (Proceq Pundit Lab) was used to evaluate the ultrasonic pulse velocity measurements for each fired clay sample as a function of temperature. It was observed that there became a relationship between physical properties and ultrasonic pulse velocities of the samples. The results showed that in consequence of increasing densification of the samples, the differences between the ultrasonic pulse velocities were higher with increasing temperature. These findings may facilitate the use of ultrasonic pulse velocity for the estimation of physical properties of fired clay samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Scott L. Stephens; Danny L. Fry
2007-01-01
Fire regimes in coast redwood forests in the northeastern Santa Cruz Mountains were determined by ring counts from 46 coast redwood stumps and live trees. The earliest recorded fire from two live samples was in 1615 and the last fire recorded was in 1884, although samples were not crossdated. For all sites combined, the mean fire return interval (FRI) was 12.0 years;...
Brandon M. Collins; Richard G. Everett; Scott L. Stephens
2011-01-01
We re-sampled areas included in an unbiased 1911 timber inventory conducted by the U.S. Forest Service over a 4000 ha study area. Over half of the re-sampled area burned in relatively recent management- and lightning-ignited fires. This allowed for comparisons of both areas that have experienced recent fire and areas with no recent fire, to the same areas historically...
Michael E. Goerndt; Francisco X. Aguilar; Kenneth Skog
2013-01-01
Past studies have established measures of co-firing potential at varying spatial scales to assess opportunities for renewable energy generation from woody biomass. This study estimated physical availability, within ecological and public policy constraints, and associated harvesting and delivery costs of woody biomass for co-firing in selected power plants of the...
Assessing accuracy of point fire intervals across landscapes with simulation modelling
Russell A. Parsons; Emily K. Heyerdahl; Robert E. Keane; Brigitte Dorner; Joseph Fall
2007-01-01
We assessed accuracy in point fire intervals using a simulation model that sampled four spatially explicit simulated fire histories. These histories varied in fire frequency and size and were simulated on a flat landscape with two forest types (dry versus mesic). We used three sampling designs (random, systematic grids, and stratified). We assessed the sensitivity of...
Farris, Calvin A; Baisan, Christopher H; Falk, Donald A; Yool, Stephen R; Swetnam, Thomas W
2010-09-01
Fire scars are used widely to reconstruct historical fire regime parameters in forests around the world. Because fire scars provide incomplete records of past fire occurrence at discrete points in space, inferences must be made to reconstruct fire frequency and extent across landscapes using spatial networks of fire-scar samples. Assessing the relative accuracy of fire-scar fire history reconstructions has been hampered due to a lack of empirical comparisons with independent fire history data sources. We carried out such a comparison in a 2780-ha ponderosa pine forest on Mica Mountain in southern Arizona (USA) for the time period 1937-2000. Using documentary records of fire perimeter maps and ignition locations, we compared reconstructions of key spatial and temporal fire regime parameters developed from documentary fire maps and independently collected fire-scar data (n = 60 plots). We found that fire-scar data provided spatially representative and complete inventories of all major fire years (> 100 ha) in the study area but failed to detect most small fires. There was a strong linear relationship between the percentage of samples recording fire scars in a given year (i.e., fire-scar synchrony) and total area burned for that year (y = 0.0003x + 0.0087, r2 = 0.96). There was also strong spatial coherence between cumulative fire frequency maps interpolated from fire-scar data and ground-mapped fire perimeters. Widely reported fire frequency summary statistics varied little between fire history data sets: fire-scar natural fire rotations (NFR) differed by < 3 yr from documentary records (29.6 yr); mean fire return intervals (MFI) for large-fire years (i.e., > or = 25% of study area burned) were identical between data sets (25.5 yr); fire-scar MFIs for all fire years differed by 1.2 yr from documentary records. The known seasonal timing of past fires based on documentary records was furthermore reconstructed accurately by observing intra-annual ring position of fire scars and using knowledge of tree-ring growth phenology in the Southwest. Our results demonstrate clearly that representative landscape-scale fire histories can be reconstructed accurately from spatially distributed fire-scar samples.
Flame-resistant pure and hybrid woven fabrics from basalt
NASA Astrophysics Data System (ADS)
Jamshaid, H.; Mishra, R.; Militky, J.
2017-10-01
This work has been formulated to investigate the burning behavior of different type of fabrics. The main concentration is to see how long the fabric resists after it catches the fire and the propagation of fire can be reduced by using flame resistant fiber i.e basalt. Basalt fiber is an environmental friendly material with low input, high output, low energy consumption and less emission. The goal of present investigations is to show the dependence of fabric flammability on its structure parameters i.e weave type, blend type etc. Fabric weaves have strong effect on flammability properties. Plain weave has the lowest burning rate as the density of the plain weave fabric is more and the structure is tight which gives less chances of flame passing through the fabric. Thermal stability is evaluated with TGA of all hybrid and nonhybrid fabrics and compared. The thermal stability of the basalt fiber is excellent. When comparing thermal analysis curves for hybrid samples it demonstrates that thermal stability of the samples containing basalt is much higher than the non- hybrid samples. Percentage weight loss is less in hybrid samples as compared to non-hybrid samples. The effectiveness of hybridization on samples may be indicated by substantial lowering of the decomposition mass. Correlation was made between flammability with the infrared radiations (IR)
NASA Astrophysics Data System (ADS)
Dintwe, Kebonye; Okin, Gregory S.; Xue, Yongkang
2017-06-01
Surface albedo is a critical parameter that controls surface energy balance. In dryland ecosystems, fires play a significant role in decreasing surface albedo, resulting in positive radiative forcing. Here we investigate the long-term effect of fire on surface albedo. We devised a method to calculate short-, medium-, and long-term effect of fire-induced radiative forcing and their relative effects on energy balance. We used Moderate Resolution Imaging Spectroradiometer (MODIS) data in our analysis, covering different vegetation classes in sub-Saharan Africa (SSA). Our analysis indicated that mean short-term fire-induced albedo change in SSA was -0.022, -0.035, and -0.041 for savannas, shrubland, and grasslands, respectively. At regional scale, mean fire-induced albedo change in savannas was -0.018 and -0.024 for northern sub-Saharan of Africa and the southern hemisphere Africa, respectively. The short-term mean fire-induced radiative forcing in burned areas in sub-Saharan Africa (SSA) was 5.41 W m-2, which contributed continental and global radiative forcings of 0.25 and 0.058 W m-2, respectively. The impact of fire in surface albedo has long-lasting effects that varies with vegetation type. The long-term energetic effects of fire-induced albedo change and associated radiative forcing were, on average, more than 19 times greater across SSA than the short-term effects, suggesting that fires exerted far more radiative forcing than previously thought. Taking into account the actual duration of fire's effect on surface albedo, we conclude that the contribution of SSA fires, globally and throughout the year, is 0.12 W m-2. These findings provide crucial information on possible impact of fire on regional climate variability.
Future trends in electrical energy generation economics in the United States
NASA Technical Reports Server (NTRS)
Schmitt, R. W.; Fox, G. R.; Shah, R. P.; Stewart, P. J.; Vermilyea, D. A.
1977-01-01
Developments related to the economics of coal-fired systems in the U.S. are mainly considered. The historical background of the U.S. electric generation industry is examined and the U.S. electrical generation characteristics in the year 1975 are considered. It is pointed out that coal-fired power plants are presently the largest source of electrical energy generation in the U.S. Questions concerning the availability and quality of coal are investigated. Currently there are plans for converting some 50 large oil and gas-fired generating plants to coal, and it is expected that coal will be the fuel used in almost all fossil-fired base load additions to generating capacity. Aspects of advanced energy conversion from coal are discussed, taking into account the performance and economic potential of the energy conversion systems.
Mark A. Finney; Charles W. McHugh; Isaac Grenfell; Karin L. Riley
2010-01-01
Components of a quantitative risk assessment were produced by simulation of burn probabilities and fire behavior variation for 134 fire planning units (FPUs) across the continental U.S. The system uses fire growth simulation of ignitions modeled from relationships between large fire occurrence and the fire danger index Energy Release Component (ERC). Simulations of 10,...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ebser, J., E-mail: Jan.Ebser@uni-konstanz.de; Sommer, D.; Fritz, S.
Local rear contacts for silicon passivated emitter and rear contact solar cells can be established by point-wise treating an Al layer with laser radiation and thereby establishing an electrical contact between Al and Si bulk through the dielectric passivation layer. In this laser fired contacts (LFC) process, Al can establish a few μm thick p{sup +}-doped Si region below the metal/Si interface and forms in this way a local back surface field which reduces carrier recombination at the contacts. In this work, the applicability of Kelvin probe force microscopy (KPFM) to the investigation of LFCs considering the p{sup +}-doping distributionmore » is demonstrated. The method is based on atomic force microscopy and enables the evaluation of the lateral 2D Fermi-level characteristics at sub-micrometer resolution. The distribution of the electrical potential and therefore the local hole concentration in and around the laser fired region can be measured. KPFM is performed on mechanically polished cross-sections of p{sup +}-doped Si regions formed by the LFC process. The sample preparation is of great importance because the KPFM signal is very surface sensitive. Furthermore, the measurement is responsive to sample illumination and the height of the applied voltage between tip and sample. With other measurement techniques like micro-Raman spectroscopy, electrochemical capacitance-voltage, and energy dispersive X-ray analysis, a high local hole concentration in the range of 10{sup 19 }cm{sup −3} is demonstrated in the laser fired region. This provides, in combination with the high spatial resolution of the doping distribution measured by KPFM, a promising approach for microscopic understanding and further optimization of the LFC process.« less
NCEP-ECPC monthly to seasonal US fire danger forecasts
J. Roads; P. Tripp; H. Juang; J. Wang; F. Fujioka; S. Chen
2010-01-01
Five National Fire Danger Rating System indices (including the Ignition Component, Energy Release Component, Burning Index, Spread Component, and the KeetchâByram Drought Index) and the Fosberg Fire Weather Index are used to characterise US fire danger. These fire danger indices and input meteorological variables, including temperature, relative humidity, precipitation...
NASA Astrophysics Data System (ADS)
Więckol-Ryk, Angelika; Smoliński, Adam
2017-10-01
Co-firing of biomass with coal for energy production is a well-known technology and plays an important role in the electricity sector. The post-combustion capture integrated with biomass-fired power plants (Bio-CCS) seems to be a new alternative for reducing greenhouse gas emissions. This study refers to the best known and advanced technology for post-combustion CO2 capture (PCC) based on a chemical absorption in monoethanolamine (MEA). The co-firing of hard coal with four types of biomass was investigated using a laboratory fixed bed reactor system. The comparison of gaseous products emitted from the combustion of coal and different biomass blends were determined using gas chromatography. Research proved that co-firing of biomass in fossil fuel power plants is beneficial for PCC process. It may also reduce the corrosion of CO2 capture installation. The oxygen concentration in the flue gases from hard coal combustion was comparable with the respective value for a fuel blend of biomass content of 20% w/w. It was also noted that an increase in biomass content in a sample from 20 to 40 % w/w increased the concentration of oxygen in the flue gas streams. However, this concentration should not have a significant impact on the rate of amine oxidative degradation.
Ranalli, Anthony J.
2004-01-01
This paper provides a detailed review of the chemical changes that occur in soil during a fire, the pathways by which nutrients are transferred from soil to surface-water bodies following a fire, and the temporal and spatial effects of fires on the concentration of nutrients in surface-water bodies during and following a fire that have been reported in the scientific literature. Thirty-nine papers from the scientific literature that represent studies that (1) were done in a variety of environments (savannas, grasslands, temperate forests, alpine forests, and so forth); (2) had a range of sampling frequency and duration, such as during and immediately following a fire (from the start of fire to 1 year later), short-term sampling (from end of fire to 3 years later), and long term-sampling (sampling for greater than 3 years following a fire); and (3) incorporated watersheds with various burn intensities, severities, and histories were reviewed and summarized. The review of the scientific literature has revealed that measurable effects of fires on streamwater quality are most likely to occur if the fire was severe enough to burn large amounts of organic matter, if windy conditions were present during the fire, if heavy rain occurred following the fire, and if the fire occurred in a watershed with steep slopes and soils with little cation-exchange capacity. Measurable effects of fires on lake- and reservoir-water quality are most likely to occur if, in addition to the factors listed for streams, the lake or reservoir is oligotrophic or mesotrophic and the residence time of water in the lake or reservoir is short relative to the length of time elevated concentrations of nutrients occur in runoff. Knowledge of whether a lake or reservoir is nitrogen or phosphorus limited is important because eutrophication of nitrogen-limited lakes may occur following a fire due to increasing nitrogen:phosphorus ratios caused by prolonged increases of nitrogen concentrations, especially nitrate.
NASA Technical Reports Server (NTRS)
Ichoku, Charles; Kaufman, Yoram J.
2003-01-01
Biomass burning is the main source of smoke aerosols and certain trace gases in the atmosphere. However, estimates of the rates of biomass consumption and emission of aerosols and trace gases from fires have not attained adequate reliability thus far. Traditional methods for deriving emission rates employ the use of emission factors e(sub x), (in g of species x per kg of biomass burned), which are difficult to measure from satellites. In this era of environmental monitoring from space, fire characterization was not a major consideration in the design of the early satellite-borne remote sensing instruments, such as AVHRR. Therefore, although they are able to provide fire location information, they were not adequately sensitive to variations in fire strength or size, because their thermal bands used for fire detection saturated at the lower end of fire radiative temperature range. As such, hitherto, satellite-based emission estimates employ proxy techniques using satellite derived fire pixel counts (which do not express the fire strength or rate of biomass consumption) or burned areas (which can only be obtained after the fire is over). The MODIS sensor, recently launched into orbit aboard EOS Terra (1999) and Aqua (2002) satellites, have a much higher saturation level and can, not only detect the fire locations 4 times daily, but also measures the at-satellite fire radiative energy (which is a measure of the fire strength) based on its 4 micron channel temperature. Also, MODIS measures the optical thickness of smoke and other aerosols. Preliminary analysis shows appreciable correlation between the MODIS-derived rates of emission of fire radiative energy and smoke over different regions across the globe. These relationships hold great promise for deriving emission coefficients, which can be used for estimating smoke aerosol emissions from MODIS active fire products. This procedure has the potential to provide more accurate emission estimates in near real-time, providing opportunities for various disaster management applications such as alerts, evacuation and, smoke dispersion forecasting.
NASA Astrophysics Data System (ADS)
Masi, G.; Chiavari, C.; Avila, J.; Esvan, J.; Raffo, S.; Bignozzi, M. C.; Asensio, M. C.; Robbiola, L.; Martini, C.
2016-03-01
Gilded bronzes are often affected by severe corrosion, due to defects in the Au layer and Au/Cu alloy galvanic coupling, stimulated by large cathodic area of the gilded layer. Galvanic corrosion, triggered by gilding defects, leads to products growth at the Au/bronze interface, inducing blistering or break-up of the Au layer. In this context, fire-gilded bronze replicas prepared by ancient methods (use of spreadable Au-Hg paste) was specifically characterised by compiling complementary spectroscopic and imaging information before/after accelerated ageing with synthetic rain. Fire-gilded bronze samples were chemically imaged in cross-section at nano-metric scale (<200 nm) using high energy and lateral resolution synchrotron radiation photoemission (HR-SRPES) of core levels and valence band after conventional characterisation of the samples by Glow Discharge optical Emission Spectroscopy (GD-OES) and conventional X-ray photoelectron spectroscopy (XPS). We have found a net surface enrichment in Zn and Sn after fire-gilding and presence of metallic Hg, Pb and Cu within the Au layer. Moreover, the composition distribution of the elements together with their oxidation has been determined. It was also revealed that metallic phases including Hg and Pb remain in the gilding after corrosion. Moreover, selective dissolution of Zn and Cu occurs in the crater due to galvanic coupling, which locally induces relative Sn species enrichment (decuprification). The feasibility advantages and disadvantages of chemical imaging using HR-SRPES to study artworks have been investigated on representative replicas.
Red imported fire ant impacts on upland arthropods in Southern Mississippi
Epperson, D.M.; Allen, Craig R.
2010-01-01
Red imported fire ants (Solenopsis invicta) have negative impacts on a broad array of invertebrate species. We investigated the impacts of fire ants on the upland arthropod community on 20???40 ha study sites in southern Mississippi. Study sites were sampled from 19972000 before, during, and after fire ant bait treatments to reduce fire ant populations. Fire ant abundance was assessed with bait transects on all sites, and fire ant population indices were estimated on a subset of study sites. Species richness and diversity of other ant species was also assessed from bait transects. Insect biomass and diversity was determined from light trap samples. Following treatments, fire ant abundance and population indices were significantly reduced, and ant species diversity and richness were greater on treated sites. Arthropod biomass, species diversity and species richness estimated from light trap samples were negatively correlated with fire ant abundance, but there were no observable treatment effects. Solenopsis invicta has the potential to negatively impact native arthropod communities resulting in a potential loss of both species and function.
Janice L. Coen; Philip J Riggan
2014-01-01
The 2006 Esperanza Fire in Riverside County, California, was simulated with the Coupled Atmosphere-Wildland Fire Environment (CAWFE) model to examine how dynamic interactions of the atmosphere with large-scale fire spread and energy release may affect observed patterns of fire behavior as mapped using the FireMapper thermal imaging radiometer. CAWFE simulated the...
Accomplishments of the American-Polish program for elimination of low emissions in Krakow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butcher, T.A.; Pierce, B.
1998-12-31
Since 1990 the US Department of Energy (DOE) has been involved in a program aimed at reducing air pollution caused by small, coal-fired sources in Poland. The activity is focused on the city of Cracow, Poland with the intention that results will be applicable and extendable to the entire region. The effort under this program has been focused into 5 main areas of interest as follows: (1) energy conservation and extension of central station district heating; (2) replacement of coal- and coke-fired boilers with natural gas-fired boilers; (3) replacement of coal-fired home stoves with electric heating appliances; (4) reduction ofmore » emissions from stoker-fired boiler houses; and (5) reduction of emissions from coal-fired home heating stoves.« less
Torpor and basking after a severe wildfire: mammalian survival strategies in a scorched landscape.
Matthews, Jaya K; Stawski, Clare; Körtner, Gerhard; Parker, Cassandra A; Geiser, Fritz
2017-02-01
Wildfires can completely obliterate above-ground vegetation, yet some small terrestrial mammals survive during and after fires. As knowledge about the physiological and behavioural adaptations that are crucial for post-wildfire survival is scant, we investigated the thermal biology of a small insectivorous marsupial (Antechinus flavipes) after a severe forest fire. Some populations of antechinus survived the fire in situ probably by hiding deep in rocky crevices, the only fire-proof sites near where they were trapped. We hypothesised that survival in the post-fire landscape was achieved by decreasing daytime activity and using torpor frequently to save energy. Indeed, daytime activity was less common and torpor expression was substantially higher (≥2-fold) at the post-fire site than observed in an unburnt control site and also in comparison to a laboratory study, both when food was provided ad libitum and withheld. Basking in the post-fire site was also recorded, which was likely used to further reduce energy expenditure. Our data suggest that torpor and basking are used by this terrestrial mammal to reduce energy and foraging requirements, which is important in a landscape where food and shelter are limited and predation pressure typically is increased.
Robert E. Keane
2006-01-01
The Fire Behavior (FB) method is used to describe the behavior of the fire and the ambient weather and fuel conditions that influence the fire behavior. Fire behavior methods are not plot based and are collected by fire event and time-date. In general, the fire behavior data are used to interpret the fire effects documented in the plot-level sampling. Unlike the other...
Airborne asbestos exposures associated with work on asbestos fire sleeve materials.
Blake, Charles L; Harbison, Stephen C; Johnson, Giffe T; Harbison, Raymond D
2011-11-01
Asbestos-containing fire sleeves have been used as a fire protection measure for aircraft fluid hoses. This investigation was conducted to determine the level of airborne asbestos fiber exposure experienced by mechanics who work with fire sleeve protected hoses. Duplicate testing was performed inside a small, enclosed workroom during the fabrication of hose assemblies. Personal air samples taken during this work showed detectable, but low airborne asbestos fiber exposures. Analysis of personal samples (n=9) using phrase contract microscopy (PCM) indicated task duration airborne fiber concentrations ranging from 0.017 to 0.063 fibers per milliliter (f/ml) for sampling durations of 167-198 min, and 0.022-0.14 f/ml for 30 min samples. Airborne chrysotile fibers were detected for four of these nine personal samples, and the resulting asbestos adjusted airborne fiber concentrations ranged from 0.014 to 0.025 f/ml. These results indicate that work with asbestos fire sleeve and fire sleeve protected hose assemblies, does not produce regulatory noncompliant levels of asbestos exposure for persons who handle, cut and fit these asbestos-containing materials. Copyright © 2011 Elsevier Inc. All rights reserved.
In-situ characterization of wildland fire behavior
Bret Butler; D. Jimenez; J. Forthofer; Paul Sopko; K. Shannon; Jim Reardon
2010-01-01
A system consisting of two enclosures has been developed to characterize wildand fire behavior: The first enclosure is a sensor/data logger combination that measures and records convective/radiant energy released by the fire. The second is a digital video camera housed in a fire proof enclosure that records visual images of fire behavior. Together this system provides...
Grechi, Daniele; Biggeri, Annibale
2016-01-01
On September 2014, a fire began within an oil refinery involving a storage tank containing several hundreds of thousands cubic meters of virgin naphtha. Mayors of neighbouring municipalities asked the Epidemiology and Prevention Society "Giulio A. Maccacaro" to carry out an environmental survey in order to evaluate what was the nature and how dangerous was suspended dust deposited by the fumes. In the following days, after fire had been extinguished we conducted a sample survey on the presence of polycyclic aromatic hydrocarbons (PAH) and metals in particulate deposited on the soil on a radius of five kilometres from the refinery and we engaged the exposed population. The Milazzo-Valle del Mela (Sicily Region, Southern Italy) high-risk area includes several industrial plants; among them, an oil refinery and a fuel powered energy plant. As reference area we selected the Sarroch municipality (Sardinia Region, Southern Italy), in the coast of the Tyrrhenian Sea, which is geographically comparable, where a large oil refinery is located and where an environmental campaign with measurement of PAH and metals in particulate matter was ongoing. Qualitatively, metal composition of particulate matter resulted similar in the Sarroch and Milazzo samples. Instead, a large excess of PAH was documented in the Milazzo samples as compared to the Sarroch ones. In conclusion, the results of the analysis of the samples of particulate matter deposited in the Milazzo area in the days immediately following the oil refinery fire showed a high quantity of PAH, carcinogenic substances which pose major hazard to population health. The greater fall-out was registered in the proximity of the burnt storage tank and the West neighbourhood, and at lesser extent in the Southern neighbourhood. As a consequence, there was a population exposure to carcinogenic substances which could have reached the food chain.
Calvin A. Farris; Christopher H. Baisan; Donald A. Falk; Stephen R. Yool; Thomas W. Swetnam
2010-01-01
Fire scars are used widely to reconstruct historical fire regime parameters in forests around the world. Because fire scars provide incomplete records of past fire occurrence at discrete points in space, inferences must be made to reconstruct fire frequency and extent across landscapes using spatial networks of fire-scar samples. Assessing the relative accuracy of fire...
Directed Diffusion Modelling for Tesso Nilo National Parks Case Study
NASA Astrophysics Data System (ADS)
Yasri, Indra; Safrianti, Ery
2018-01-01
— Directed Diffusion (DD has ability to achieve energy efficiency in Wireless Sensor Network (WSN). This paper proposes Directed Diffusion (DD) modelling for Tesso Nilo National Parks (TNNP) case study. There are 4 stages of scenarios involved in this modelling. It’s started by appointing of sampling area through GPS coordinate. The sampling area is determined by optimization processes from 500m x 500m up to 1000m x 1000m with 100m increment in between. The next stage is sensor node placement. Sensor node is distributed in sampling area with three different quantities i.e. 20 nodes, 30 nodes and 40 nodes. One of those quantities is choose as an optimized sensor node placement. The third stage is to implement all scenarios in stages 1 and stages 2 on DD modelling. In the last stage, the evaluation process to achieve most energy efficient in the combination of optimized sampling area and optimized sensor node placement on Direct Diffusion (DD) routing protocol. The result shows combination between sampling area 500m x 500m and 20 nodes able to achieve energy efficient to support a forest preventive fire system at Tesso Nilo National Parks.
NASA Astrophysics Data System (ADS)
Youness, Rasha A.; Taha, Mohammed A.; Ibrahim, Medhat A.
2017-12-01
Titanium-containing carbonated hydroxyapatite (Ti-CHA) nanocomposite powders, with different CHA contents, have been prepared using high-energy ball milling method. The effect of sintering temperatures, 900, 1100 and 1300 °C on molecular structure and microstructure of these samples were examined by XRD; Fourier transform infrared (FTIR) spectroscopy and scanning electron microscopy (SEM), respectively. Furthermore, their mechanical properties including hardness, longitudinal modulus, Young's modulus, shear modulus, bulk modulus and Poisson's ratio were measured by ultrasonic non-destructive technique. Moreover, bioactivity of sintered samples at different firing temperatures was assessed by immersing them in simulated body fluid at 37 ± 0.5 °C for 7 days and then, analyzed by FTIR spectroscopy. The results pointed out that increasing sintering temperature up to 1100 °C caused significant increases in densities and mechanical properties of these nanocomposite samples. However, further increase of firing temperature to 1300 °C was responsible for complete CHA decomposition and the resultant α-tricalcium (α-TCP) phase greatly affected these properties. On the contrary, better bioactivity was observed for sintered samples at 900 °C only. However, increase of sintering temperature of these samples up to 1300 °C led to severe decrease in their bioactivity due to the formation of highly soluble α-TCP phase.
Evaluation of the release of dioxins and PCBs during kiln-firing of ball clay.
Broadwater, Kendra; Meeker, John D; Luksemburg, William; Maier, Martha; Garabrant, David; Demond, Avery; Franzblau, Alfred
2014-01-01
Ball clay is known to be naturally contaminated with high levels of polychlorinated di-benzo-p-dioxins (PCDDs). This study evaluated the potential for PCDD, polychlorinated dibenzofuran (PCDF) and polychlorinated biphenyl (PCB) release during the kiln firing of ball clay in an art studio. Toxic equivalence (TEQ) were calculated using World Health Organization (WHO) 2005 toxic equivalence factors (TEF) and congener concentrations. Ten bags of commercial ball clay were found to have an average TEQ of 1,370 nanograms/kilogram (ng kg(-1)) dry weight (dw), almost exclusively due to PCDDs (99.98% of TEQ). After firing, none of the 29 dioxin-like analytes was measured above the limits of detection (LOD) in the clay samples. Air samples were taken during firings using both low-flow and high-flow air samplers. Few low-flow air samples contained measurable levels of dioxin congeners above the LOD. The mean TEQ in the high volume air samples ranged from 0.07 pg m(-3) to 0.21 pg m(-3) when firing ball clay, and was 0.11 pg m(-3) when no clay was fired. These concentrations are within the range measured in typical residences and well-controlled industrial settings. The congener profiles in the high-flow air samples differed from the unfired clay; the air samples had a considerable contribution to the TEQ from PCDFs and PCBs. Given that the TEQs of all air samples were very low and the profiles differed from the unfired clay, it is likely that the PCDDs in dry ball clay were destroyed during kiln firing. These results suggest that inhalation of volatilized dioxins during kiln firing of dry ball clay is an unlikely source of exposure for vocational and art ceramicists. Copyright © 2013 Elsevier Ltd. All rights reserved.
Di, Zhou; Li-Xia, Pang; Ze-Ming, Qi; Biao-Bing, Jin; Xi, Yao
2014-01-01
A novel NaAgMoO4 material with spinel-like structure was synthesized by using the solid state reaction method and the ceramic sample was well densified at an extreme low sintering temperature about 400°C. Rietveld refinement of the crystal structure was performed using FULLPROF program and the cell parameters are a = b = c = 9.22039 Å with a space group F D −3 M (227). High performance microwave dielectric properties, with a permittivity ~7.9, a Qf value ~33,000 GHz and a temperature coefficient of resonant frequency ~−120 ppm/°C, were obtained. From X-ray diffraction (XRD) and Energy Dispersive Spectrometer (EDS) analysis of the co-fired sample, it was found that the NaAgMoO4 ceramic is chemically compatible with both silver and aluminum at the sintering temperature and this makes it a promising candidate for the ultra-low temperature co-fired ceramics technology. Analysis of infrared and THz spectra indicated that dielectric polarizability at microwave region of the NaAgMoO4 ceramic was equally contributed by ionic displasive and electronic polarizations. Its small microwave dielectric permittivity can also be explained well by the Shannon's additive rule. PMID:25099530
Melquiades, Fábio L; Thomaz, Edivaldo L
2016-05-01
An important aspect for the evaluation of fire effects in slash-and-burn agricultural system, as well as in wildfire, is the soil burn severity. The objective of this study is to estimate the maximum temperature reached in real soil burn events using energy dispersive X-ray fluorescence (EDXRF) as an analytical tool, combined with partial least square (PLS) regression. Muffle-heated soil samples were used for PLS regression model calibration and two real slash-and-burn soils were tested as external samples in the model. It was possible to associate EDXRF spectra alterations to the maximum temperature reached in the heat affected soils with about 17% relative standard deviation. The results are promising since the analysis is fast, nondestructive, and conducted after the burn event, although local calibration for each type of burned soil is necessary. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Diana Yemilet Avila Flores; Marco Aurelio González Tagle; Javier Jiménez Pérez; Oscar Aguirre Calderón; Eduardo Treviño Garza
2013-01-01
The objective of this research was to characterize the spatial structure patterns of a Pinus hartwegii forest in the Sierra Madre Oriental, affected by a fire in 1998. Sampling was stratified by fire severity. A total of three fire severity classes (low, medium and high) were defined. Three sample plots of 40m x 40m were established for each...
AmeriFlux US-An1 Anaktuvuk River Severe Burn
Hobbie, John [Marine Biological Laboratory; Rocha, Adrian [Marine Biological Laboratory; Shaver, Gaius [Marine Biological Laboratory
2016-01-01
This is the AmeriFlux version of the carbon flux data for the site US-An1 Anaktuvuk River Severe Burn. Site Description - The Anaktuvuk River fire on the North Slope of Alaska started on July 16, 2007 by lightning. It continued until the end of September when nearby lakes had already frozen over and burned >256,000 acres, creating a mosaic of patches that differed in burn severity. The Anaktuvuk River Severe Burn, Moderate Burn, and Unburned sites are 40 km to the west of the nearest road and were selected in late May 2008 to determine the effects of the fire on carbon, water, and energy exchanges during the growing season. Because the fire had burned through September of the previous year, initial deployment of flux towers occurred prior to any significant vegetative regrowth, and our sampling campaign captured the full growing season in 2008. The Severe Burn site consisted of a large area in which all of the green vegetation were consumed in the fire and some of the organic matter had burnt to the mineral soil in many places. A bear damaged the tower during the last week of August 2008, and it was repaired shortly after.
An assessment of climate and fire danger rating in the Northern Rockies during the 1910 fire season
Charles W. McHugh; Mark A. Finney; Larry S. Bradshaw
2010-01-01
The 1910 fires of western Montana and northern Idaho have received much publicity in the popular media but little scientific attention regarding the factors that contribute to fire behavior and fire danger. Here we present information surrounding the weather, and reconstructed measures of Palmer Drought Severity Index (PDSI), Keetch-Byram Drought Index (KBDI), Energy...
Pereira, Paulo; Cerda, Artemi; Martin, Deborah; Úbeda, Xavier; Depellegrin, Daniel; Novara, Agata; Martínez-Murillo, Juan F; Brevik, Eric C; Menshov, Oleksandr; Comino, Jesus Rodrigo; Miesel, Jessica
2017-02-01
Spring grassland fires are common in boreal areas as a consequence of slash and burn agriculture used to remove dry grass to increase soil nutrient properties and crop production. However, few works have investigated fire impacts on these grassland ecosystems, especially in the immediate period after the fire. The objective of this work was to study the short-term impacts of a spring grassland fire in Lithuania. Four days after the fire we established a 400m 2 sampling grid within the burned area and in an adjacent unburned area with the same topographical, hydrological and pedological characteristics. We collected topsoil samples immediately after the fire (0months), 2, 5, 7 and 9months after the fire. We analysed soil pH, electrical conductivity (EC), major nutrients including calcium (Ca), magnesium (Mg), sodium (Na), and potassium (K), and the minor elements aluminium (Al), manganese (Mn), iron (Fe) and zinc (Zn). We also calculated the soil Na and K adsorption ratio (SPAR), Ca:Mg and Ca:Al. The results showed that this low-severity grassland fire significantly decreased soil pH, Al, and Mn but increased EC, Ca, Mg, and K,. There was no effect on Na, Fe, and Zn. There was a decrease of EC, Ca, Mg, and Na from 0months after the fire until 7months after the fire, with an increase during the last sampling period. Fire did not significantly affect SPAR. Ca:Mg decreased significantly immediately after the fire, but not to critical levels. Ca:Al increased after the fire, reducing the potential effects of Al on plants. Overall, fire impacts were mainly limited to the immediate period after the fire. Copyright © 2016 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-04
... frame that is not necessarily a NEMA- equivalent but otherwise covered under EISA 2007) that is June 4.... Definition of NEMA Design B Motors E. Fire Pump Motors Definition F. Fire Pump Motor Coverage G. Energy... provisions designed to improve appliance and commercial equipment energy efficiency. (All references to EPCA...
Surface forcing of non-stand-replacing fires in Siberian larch forests
NASA Astrophysics Data System (ADS)
Chen, Dong; Loboda, Tatiana V.
2018-04-01
Wildfires are the dominant disturbance agent in the Siberian larch forests. Extensive low- to mediate-intensity non-stand-replacing fires are a notable property of fire regime in these forests. Recent large scale studies of these fires have focused mostly on their impacts on carbon budget; however, their potential impacts on energy budget through post-fire albedo changes have not been considered. This study quantifies the post-fire surface forcing for Siberian larch forests that experienced non-stand-replacing fires between 2001 and 2012 using the full record of MODIS MCD43A3 albedo product and a burned area product developed specifically for the Russian forests. Despite a large variability, the mean effect of non-stand-replacing fires imposed through albedo is a negative forcing which lasts for at least 14 years. However, the magnitude of the forcing is much smaller than that imposed by stand-replacing fires, highlighting the importance of differentiating between the two fire types in the studies involving the fire impacts in the region. The results of this study also show that MODIS-based summer differenced normalized burn ratio (dNBR) provides a reliable metric for differentiating non-stand-replacing from stand-replacing fires with an overall accuracy of 88%, which is of considerable importance for future work on modeling post-fire energy budget and carbon budget in the region.
Bret Butler; C. Teske; Dan Jimenez; Joseph O' Brien; Paul Sopko; Cyle Wold; Mark Vosburgh; Ben Hornsby; E. Louise Loudermilk
2016-01-01
Wildland fire rate of spread (ROS) and intensity are determined by the mode and magnitude of energy transport from the flames to the unburned fuels. Measurements of radiant and convective heating and cooling from experimental fires are reported here. Sensors were located nominally 0.5mabove ground level. Flame heights varied from 0.3 to 1.8 m and flaming zone depth...
PM2.5 and Carbon Emissions from Prescribed Fire in a Longleaf Pine Ecosystem
NASA Astrophysics Data System (ADS)
Strenfel, S. J.; Clements, C. B.; Hiers, J. K.; Kiefer, C. M.
2008-12-01
Prescribed fires are a frequently utilized land-management tool in the Southeastern US. In order to better characterize emissions and impacts from prescribed fire in longleaf pine ecosystems, in situ data were obtained within the burn perimeter using a 10-m instrumented flux tower. Turbulence and temperature data at 10-m were sampled at 10 Hz using a sonic anemometer and fine-wire thermocouples respectively. Measurements of PM2.5, CO and CO2 emissions were sampled at 10-m within the burn perimeter and PM2.5 and Black Carbon PM2.5 were sampled 0.5 km downwind of the fire front using a 2-m instrumented tripod. Preliminary results indicate PM2.5 and carbon emissions significantly increased during the fire-front passage, and downwind PM concentrations were amplified beyond pre-fire ambient concentrations. In addition, the considerable amount a heat release and flux data gathered from these prescribed fires suggests that near surface atmospheric conditions were directly impacted by increased turbulence generation.
Progress toward the determination of correct classification rates in fire debris analysis.
Waddell, Erin E; Song, Emma T; Rinke, Caitlin N; Williams, Mary R; Sigman, Michael E
2013-07-01
Principal components analysis (PCA), linear discriminant analysis (LDA), and quadratic discriminant analysis (QDA) were used to develop a multistep classification procedure for determining the presence of ignitable liquid residue in fire debris and assigning any ignitable liquid residue present into the classes defined under the American Society for Testing and Materials (ASTM) E 1618-10 standard method. A multistep classification procedure was tested by cross-validation based on model data sets comprised of the time-averaged mass spectra (also referred to as total ion spectra) of commercial ignitable liquids and pyrolysis products from common building materials and household furnishings (referred to simply as substrates). Fire debris samples from laboratory-scale and field test burns were also used to test the model. The optimal model's true-positive rate was 81.3% for cross-validation samples and 70.9% for fire debris samples. The false-positive rate was 9.9% for cross-validation samples and 8.9% for fire debris samples. © 2013 American Academy of Forensic Sciences.
NASA Astrophysics Data System (ADS)
Barnes, R. T.; Gilbertson, A.; Maxwell, K.
2017-12-01
Disturbance strongly regulates material and energy flows, changing ecosystem pattern and process. An increase in the size and severity of fire, particularly in the Intermountain West, over the last several decades is expected to continue due to a warming climate. Predicting how fire will alter the net ecosystem carbon balance requires us to understand how carbon is stored, processed, and transferred. Here we present results from paired watersheds focused on five 2002 severe fires in Colorado to examine how organic matter is processed along the hillslope and within the stream. Comparing soil samples and water extractable organic matter (WEOM) between burned and unburned sites illustrates the impact of fire: burned soils have 50% organic matter (OM) content as unburned soils, regardless of geomorphic position. While a smaller pool, soil OM (SOM) in burned sites is more susceptible to microbial degradation (p<0.001 for 4 of 6 sites), especially in systems with slower vegetative recovery. This is explained, in part, to the water extractable organic matter (WEOM) from unburned soils having a higher C:N than burned sites (p<0.02). This shift in SOM quality is likely due to differing OM inputs (e.g. grasses and forbes vs. trees in burned vs. unburned sites). Comparing results from intact soil column experiments to soil extractions and stream samples, suggests that the majority of this soil derived WEOM does not make it to the stream, potentially getting sorbed deeper in the mineral rich, organic poor, portion of the soil. Interestingly, the systematic shifts in OM amounts and quality (as measured by SUVA, E2:E3, and fluorescence) within the terrestrial system in response to fire, are not seen in stream exports. As such, while there are significant relationships (p<0.05) between stream DOM quality, DOM bioavailability, and stream metabolism, burned watersheds are not exporting DOM that is more bioavailable. In addition, despite different terrestrial OM pools, burned and unburned watersheds export statistically similar amounts of DOM per unit area, suggesting that a larger fraction of OM is transferred from the terrestrial to aquatic ecosystem within fire affected landscapes.
Modeling Payload Stowage Impacts on Fire Risks On-Board the International Space Station
NASA Technical Reports Server (NTRS)
Anton, Kellie e.; Brown, Patrick F.
2010-01-01
The purpose of this presentation is to determine the risks of fire on-board the ISS due to non-standard stowage. ISS stowage is constantly being reexamined for optimality. Non-standard stowage involves stowing items outside of rack drawers, and fire risk is a key concern and is heavily mitigated. A Methodology is needed to account for fire risk due to non-standard stowage to capture the risk. The contents include: 1) Fire Risk Background; 2) General Assumptions; 3) Modeling Techniques; 4) Event Sequence Diagram (ESD); 5) Qualitative Fire Analysis; 6) Sample Qualitative Results for Fire Risk; 7) Qualitative Stowage Analysis; 8) Sample Qualitative Results for Non-Standard Stowage; and 9) Quantitative Analysis Basic Event Data.
Impact of postfire management on soil respiration and C concentration in a managed hemiboreal forest
NASA Astrophysics Data System (ADS)
Köster, Kajar; Seglinš, Katrin; Parro, Kristi; Metslaid, Marek
2017-04-01
Fire is the main natural disturbance in boreal forests and it is expected that its frequency will increase as a result of climate change. Fire is the primary process which organizes the physical and biological attributes of the boreal biome and influences energy flows and biogeochemical cycles, particularly the carbon (C) cycle. The objective of this study was to assess the impact of forest fire and time since forest fire on soil respiration and soil C concentrations in scenarios where the area was managed or was not managed after fire disturbance. This study was carried out in two permanent research areas in northwestern Estonia (hemiboreal forest zone) that were damaged by fire: Vihterpalu (59o13' N 23o49' E) and Nõva (59o10' N 23o45' E). Fire occurred in Vihterpalu in year 1992 (550 ha burned), when the forest was 52 years old, and in Nõva in year 2008 (800 ha burned), when the forest was 70 years old. Before the fire disturbance both sites were covered with planted or sown Scots pine (Pinus sylvestris L.) forests originally regenerated after heavy fires in 1940 (Nõva) and 1951 (Vihterpalu). In all areas we are dealing with stand replacing fires where all (or almost all) of the stand was destroyed by fire. In both study areas three different types of sample areas were set up: 1) control areas (CO), that are unburned and no management activities carried out; 2) burned and cleared (BC) with salvage logging, areas in which all dead and live trees were harvested from the plot after fire; 3) burned and uncleared areas (BU), areas without management in which both dead and live trees were left on the plots after fire disturbance. On every area three measuring transects (40 m long) were established where soil respiration (g CO2 m-2h-1) was measured on five collars, and five soil samples (0.5 m long and 0.05 m in diameter) were taken to estimate soil C (kg m-2) content. In our study, highest soil respiration values were recorded in control (CO) areas, which are not affected by forest fires. In the fire areas (BC and BU) the average soil respiration values were more than two times lower than in the areas which were not affected by forest fires. Different post-fire management activities (removing or leaving damaged trees) did not affect the soil respiration values. Soil temperature had a significant impact on the CO2 flows. The recorded average soil temperature was lowest in CO and highest in BU areas, respectively. In spring and autumn soil temperatures in disturbed areas, as well as in cleared areas, were rising faster than in CO areas. In our study, 1992 fire areas had thicker litter and organic layer compared to 2008 fire areas. Most of the litter and organic matter was found in CO areas, followed by BU and BC areas. The highest C concentrations were found in CO areas. In the fire areas C concentration was also affected by the post-disturbance management, as in BC areas soil C concentration was lower compared to BU areas.
NASA Astrophysics Data System (ADS)
Liu, Junhui; Yang, Jianlian; Wang, Jiangbo; Yang, Meng; Tian, Chunzheng; He, Xinhui
2018-01-01
With grid-connected scale of clean energy such as wind power and photovoltaic power expanding rapidly and cross-province transmission scale being bigger, utilization hours of coal-fired power generation units become lower and lower in the context of the current slowdown in electricity demand. This paper analyzes the influencing factors from the three aspects of demand, supply and supply and demand balance, and the mathematical model has been constructed based on the electric energy balance. The utilization hours of coal-fired power generation units have been solved considering the relationship among proportion of various types of power installed capacity, the output rate and utilization hours. By carrying out empirical research in Henan Province, the utilization hours of coal-fired units of Henan Province in 2020 has been achieved. The example validates the practicability and the rationality of the model, which can provide a basis for the decision-making for coal-fired power generation enterprises.
Grabowska, Teresa; Skowronek, Rafał; Nowicka, Joanna; Sybirska, Halina
2012-09-01
Hydrogen cyanide (HCN) is one of the most toxic components of fire smoke, but insufficient attention is paid to its potential role as a cause of injury or death in victims (alive or dead) of enclosed-space fires. To analyse the prevalence of toxic HCN exposure in fire victims and factors that may influence its toxicity, particularly the co-presence of carbon monoxide (CO) and ethanol. Blood samples from fire victims and persons rescued from fires were analysed. A positive result for HCN (mean concentration 16.83 mg/l) was detected in blood samples from 169 of 285 fire-related deaths (59%). Ethanol was present in 91 (65%) of 139 samples with coincident presence of HCN and carboxyhaemoglobin (COHb). HCN (mean 4.0 mg/l) was also detected in 20 of 40 (50%) fire survivors. The high prevalence of coincident CO and HCN in enclosed-space, fire-related deaths should alert clinicians to suspect toxic HCN exposure in all persons rescued from fire with signs and symptoms of respiratory distress. Medical procedures in persons rescued from enclosed-space fires, especially in the pre-hospital setting, should be augmented to cover the possibility of toxic HCN exposure, particularly in individuals who do not respond to standard supportive therapy. Likewise, post-mortem investigations should routinely include assays for HCN when determining probable cause of death.
Martínez, M; Díaz-Ferrero, J; Martí, R; Broto-Puig, F; Comellas, L; Rodríguez-Larena, M C
2000-12-01
Only a few data are reported about the formation of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) in forest fires. However, the inventories of sources undertaken by several European and American countries consider natural fires as a possible source of PCDD/F and, in some cases, as one of the most important. In our work we have analysed vegetation and soil samples burned in four forest fires which happened in Catalonia in the summer of 1998. The concentration of dioxin-like compounds (PCDD/F, non-ortho polychlorinated bi-phenyls (PCB) and mono-ortho PCB) has been compared to the concentration present in the corresponding unburned material collected in places near the fires but not affected. The results of this preliminary study show very low concentrations in all the samples, both burned and unburned. Although a change in the profile (proportional increase of tetrachlorinated congeners in PCDD/F) is observed in burned samples compared to unburned ones, the absolute values of concentration decrease in most samples. Therefore, natural fires seem not to be an important source of dioxin-like compounds. These results will be confirmed with air emissions measurements in future studies.
Manies, K.L.; Harden, J.W.; Veldhuis, Hugo; Trumbore, Sue
2006-01-01
The U.S. Geological Survey project Fate of Carbon in Alaskan Landscapes (FOCAL) is studying the effect of fire and soil drainage on soil carbon storage in the boreal forest. As such this group was invited to be a part of a NSF-funded project (Fire, Ecosystem and Succession - Experiment Boreal or FIRES-ExB) to study the carbon balance of sites that varied in age (time since fire) and soil drainage in the Thompson, Manitoba, Canada region. This report describes the location of our FIRES-ExB sampling sites as well as the procedures used to describe, sample, and analyze the soils. This report also contains data tables with sample related information including, but not limited to, field descriptions, bulk density, particle size distribution, moisture content, carbon (C) concentration, nitrogen (N) concentration, isotopic data for C, and major, minor and trace elemental concentration.
Xue, Gang; Song, Wen-qi; Li, Shu-chao
2015-01-01
In order to achieve the rapid identification of fire resistive coating for steel structure of different brands in circulating, a new method for the fast discrimination of varieties of fire resistive coating for steel structure by means of near infrared spectroscopy was proposed. The raster scanning near infrared spectroscopy instrument and near infrared diffuse reflectance spectroscopy were applied to collect the spectral curve of different brands of fire resistive coating for steel structure and the spectral data were preprocessed with standard normal variate transformation(standard normal variate transformation, SNV) and Norris second derivative. The principal component analysis (principal component analysis, PCA)was used to near infrared spectra for cluster analysis. The analysis results showed that the cumulate reliabilities of PC1 to PC5 were 99. 791%. The 3-dimentional plot was drawn with the scores of PC1, PC2 and PC3 X 10, which appeared to provide the best clustering of the varieties of fire resistive coating for steel structure. A total of 150 fire resistive coating samples were divided into calibration set and validation set randomly, the calibration set had 125 samples with 25 samples of each variety, and the validation set had 25 samples with 5 samples of each variety. According to the principal component scores of unknown samples, Mahalanobis distance values between each variety and unknown samples were calculated to realize the discrimination of different varieties. The qualitative analysis model for external verification of unknown samples is a 10% recognition ration. The results demonstrated that this identification method can be used as a rapid, accurate method to identify the classification of fire resistive coating for steel structure and provide technical reference for market regulation.
46 CFR 161.002-2 - Types of fire-protective systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample... unit, fire detectors, smoke detectors, and audible and visual alarms distinct in both respects from the alarms of any other system not indicating fire. (c) Manual fire alarm systems. For the purpose of this...
NASA Astrophysics Data System (ADS)
Sparks, A. M.; Kolden, C.; Smith, A. M.
2016-12-01
Fire activity, in terms of intensity, frequency, and total area burned, is expected to increase with changing climate. A challenge for landscape level assessment of fire effects, termed burn severity, is that current assessments provide very little information regarding vegetation physiological performance and recovery, limiting our understanding of fire effects on ecosystem services such as carbon storage/cycling. To address these limitations, we evaluated an alternative dose-response methodology for quantifying fire effects that attempts to bridge fire combustion dynamics and ecophysiology. Specifically, we conducted a highly controlled, laboratory assessment of seedling response to increasing doses of fire radiative energy applied through surface fires, for two western U.S. conifer species. Seedling physiology and spectral reflectance were acquired pre- and up to 1 year post-fire. Post-fire mortality, physiological performance, and spectral reflectance were strongly related with fire radiative energy density (FRED: J m-2) dose. To examine how these relationships change with tree size and age, we conducted small prescribed fires at the tree scale (35 m2) in a mature conifer stand. Radial growth and resin duct defenses were assessed on the mature conifer trees following the prescribed fires. Differences in dose-response relationships between seedlings and mature trees indicate the importance of fire behavior (e.g., flaming-dominated versus smoldering-dominated combustion) in characterizing these relationships. Ultimately, these results suggest that post-fire impacts on growth of surviving seedlings and mature trees require modes of heat transfer to impact tree canopies.
Zachary A. Holden; W. Matt Jolly
2011-01-01
Fire danger rating systems commonly ignore fine scale, topographically-induced weather variations. These variations will likely create heterogeneous, landscape-scale fire danger conditions that have never been examined in detail. We modeled the evolution of fuel moistures and the Energy Release Component (ERC) from the US National Fire Danger Rating System across the...
Combining turbulent kinetic energy and Haines Index predictions for fire-weather assessments
Warren E. Heilman; Xindi Bian
2007-01-01
The 24- to 72-hour fire-weather predictions for different regions of the United States are now readily available from the regional Fire Consortia for Advanced Modeling of Meteorology and Smoke (FCAMMS) that were established as part of the U.S. National Fire Plan. These predictions are based on daily real-time MM5 model simulations of atmospheric conditions and fire-...
Biomass consumption during prescribed fires in big sagebrush ecosystems
Clinton S. Wright; Susan J. Prichard
2006-01-01
Big sagebrush (Artemisia tridentata) ecosystems typically experience stand replacing fires during which some or all of the ignited biomass is consumed. Biomass consumption is directly related to the energy released during a fire, and is an important factor that determines smoke production and the effects of fire on other resources. Consumption of...
Seasonal fire danger forecasts for the USA
J. Roads; F. Fujioka; S. Chen; R. Burgan
2005-01-01
The Scripps Experimental Climate Prediction Center has been making experimental, near-real-time, weekly to seasonal fire danger forecasts for the past 5 years. US fire danger forecasts and validations are based on standard indices from the National Fire Danger Rating System (DFDRS), which include the ignition component (IC), energy release component (ER), burning...
Reformulation of Rothermel's wildland fire behaviour model for heterogeneous fuelbeds.
David V. Sandberg; Cynthia L. Riccardi; Mark D. Schaaf
2007-01-01
Abstract: The Fuel Characteristic Classification System (FCCS) includes equations that calculate energy release and one-dimensional spread rate in quasi-steady-state fires in heterogeneous but spatially uniform wildland fuelbeds, using a reformulation of the widely used Rothermel fire spread model. This reformulation provides an automated means to predict fire behavior...
A method for ensemble wildland fire simulation
Mark A. Finney; Isaac C. Grenfell; Charles W. McHugh; Robert C. Seli; Diane Trethewey; Richard D. Stratton; Stuart Brittain
2011-01-01
An ensemble simulation system that accounts for uncertainty in long-range weather conditions and two-dimensional wildland fire spread is described. Fuel moisture is expressed based on the energy release component, a US fire danger rating index, and its variation throughout the fire season is modeled using time series analysis of historical weather data. This analysis...
Landscape scale vegetation-type conversion and fire hazard in the San Francisco bay area open spaces
Russell, W.H.; McBride, J.R.
2003-01-01
Successional pressures resulting from fire suppression and reduced grazing have resulted in vegetation-type conversion in the open spaces surrounding the urbanized areas of the San Francisco bay area. Coverage of various vegetation types were sampled on seven sites using a chronosequence of remote images in order to measure change over time. Results suggest a significant conversion of grassland to shrubland dominated by Baccharis pilularison five of the seven sites sampled. An increase in Pseudotsuga menziesii coverage was also measured on the sites where it was present. Increases fuel and fire hazard were determined through field sampling and use of the FARSITE fire area simulator. A significant increase in biomass resulting from succession of grass-dominated to shrub-dominated communities was evident. In addition, results from the FARSITE simulations indicated significantly higher fire-line intensity, and flame length associated with shrublands over all other vegetation types sampled. These results indicate that the replacement of grass dominated with shrub-dominated landscapes has increased the probability of high intensity fires. ?? 2003 Elsevier Science B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Näthe, Kerstin; Michalzik, Beate; Levia, Delphis; Steffens, Markus
2016-04-01
Fires represent an ecosystem disturbance and are recognized to seriously pertubate the nutrient budgets of forested ecosystems. While the effects of fires on chemical, biological, and physical soil properties have been intensively studied, especially in Mediterranean areas and North America, few investigations examined the effects of fire-induced alterations in the water-bound fluxes and the chemical composition of dissolved and particulate organic carbon and nitrogen (DOC, POC, DN, PN). The exclusion of the particulate organic matter fraction (0.45 μm < POM < 500 μm) potentially results in misleading inferences and budgeting gaps when studying the effects of fires on nutrient and energy fluxes. To our best knowledge, this is the first known study to present fire-induced changes on the composition of dissolved and total organic matter (DOM, TOM) in forest floor (FF) and soil solutions (A, B horizon) from Scots pine forests in Germany. In relation to control sites, we test the effects of low-severity fires on: (1) the composition of DOM and TOM in forest floor and soil solutions; and (2) the translocated amount of particulate in relation to DOC and DN into the subsoil. The project aims to uncover the mechanisms of water-bound organic matter transport along an ecosystem profile and its compositional changes following a fire disturbance. Forest floor and soil solutions were fortnightly sampled from March to December 2014 on fire-manipulated and control plots in a Scots pine forest in Central Germany. Shortly after the experimental duff fire in April 2014 pooled solutions samples were taken for solid-state 13C NMR spectroscopy to characterize DOM (filtered solution < 0.8μm pore size) and TOM in unfiltered solutions. Independent from fire manipulation, the composition of TOM was generally less aromatic (aromaticity index [%] according to Hatcher et al., 1981) with values between 18 (FF) - 25% (B horizon) than the DOM fraction with 23 (FF) - 27% (B horizon). For DOM in FF solution, fire manipulation caused an increase in aromaticity from 23 to 27% compared to the control, due to an increase of the aryl-C and a decrease of the O-alkyl-C and alkyl-C signal. Fire effects were leveled out in the mineral soil. For TOM, fire effects became notable only in the A horizon, exhibiting a decrease in aromaticity from 22 to 18% compared to the control, due to increased O-alkyl-C and diminished aryl-C proportions. Compared to the control, fire only caused minor DOC release rates (< 10%) in the FF and mineral soil, while DN in the FF was significantly mobilized (+ 40%) by fire exhibiting annual values of 33 at the control sites compared to 46 kg DN ha-1 at the fire treated sites. Compared to the control, fire events did not significantly enhance the proportion of POC and PN in the total C and N amounts exhibiting values between 10 and 20%. To fully understand the quality and amount of translocated organic C and N compounds within soils under both ambient as well as fire environments, dissolved and particulate size fractions need to be considered.
Robertson, A. H.; Larivière, C.; Leduc, C. R.; McGillis, Z.; Eger, T.; Godwin, A.; Larivière, M.; Dorman, S. C.
2017-01-01
Introduction The seasonal profession of wildland fire fighting in Canada requires individuals to work in harsh environmental conditions that are physically demanding. The purpose of this study was to use novel technologies to evaluate the physiological demands and nutritional practices of Canadian FireRangers during fire deployments. Methods Participants (n = 21) from a northern Ontario Fire Base volunteered for this study and data collection occurred during the 2014 fire season and included Initial Attack (IA), Project Fire (P), and Fire Base (B) deployments. Deployment-specific energy demands and physiological responses were measured using heart-rate variability (HRV) monitoring devices (Zephyr BioHarness3 units). Food consumption behaviour and nutrient quantity and quality were captured using audio-video food logs on iPod Touches and analyzed by NutriBase Pro 11 software. Results Insufficient kilocalories were consumed relative to expenditure for all deployment types. Average daily kilocalories consumed: IA: 3758 (80% consumption rate); P: 2945±888.8; B: 2433±570.8. Average daily kilocalorie expenditure: IA: 4538±106.3; P: 4012±1164.8; B: 2842±649.9. The Average Macronutrient Distribution Range (AMDR) for protein was acceptable: 22–25% (across deployment types). Whereas the AMDR for fat and carbohydrates were high: 40–50%; and low: 27–37% respectively, across deployment types. Conclusions This study is the first to use the described methodology to simultaneously evaluate energy expenditures and nutritional practices in an occupational setting. The results support the use of HRV monitoring and video-food capture, in occupational field settings, to assess job demands. FireRangers expended the most energy during IA, and the least during B deployments. These results indicate the need to develop strategies centered on maintaining physical fitness and improving food practices. PMID:28107380
Robertson, A H; Larivière, C; Leduc, C R; McGillis, Z; Eger, T; Godwin, A; Larivière, M; Dorman, S C
2017-01-01
The seasonal profession of wildland fire fighting in Canada requires individuals to work in harsh environmental conditions that are physically demanding. The purpose of this study was to use novel technologies to evaluate the physiological demands and nutritional practices of Canadian FireRangers during fire deployments. Participants (n = 21) from a northern Ontario Fire Base volunteered for this study and data collection occurred during the 2014 fire season and included Initial Attack (IA), Project Fire (P), and Fire Base (B) deployments. Deployment-specific energy demands and physiological responses were measured using heart-rate variability (HRV) monitoring devices (Zephyr BioHarness3 units). Food consumption behaviour and nutrient quantity and quality were captured using audio-video food logs on iPod Touches and analyzed by NutriBase Pro 11 software. Insufficient kilocalories were consumed relative to expenditure for all deployment types. Average daily kilocalories consumed: IA: 3758 (80% consumption rate); P: 2945±888.8; B: 2433±570.8. Average daily kilocalorie expenditure: IA: 4538±106.3; P: 4012±1164.8; B: 2842±649.9. The Average Macronutrient Distribution Range (AMDR) for protein was acceptable: 22-25% (across deployment types). Whereas the AMDR for fat and carbohydrates were high: 40-50%; and low: 27-37% respectively, across deployment types. This study is the first to use the described methodology to simultaneously evaluate energy expenditures and nutritional practices in an occupational setting. The results support the use of HRV monitoring and video-food capture, in occupational field settings, to assess job demands. FireRangers expended the most energy during IA, and the least during B deployments. These results indicate the need to develop strategies centered on maintaining physical fitness and improving food practices.
NASA Astrophysics Data System (ADS)
Yin, Libao; Liao, Yanfen; Zhou, Lianjie; Wang, Zhao; Ma, Xiaoqian
2017-05-01
The life cycle assessment and environmental impacts of a 1000MW coal-fired power plant were carried out in this paper. The results showed that the operation energy consumption and pollutant emission of the power plant are the highest in all sub-process, which accounts for 93.93% of the total energy consumption and 92.20% of the total emission. Compared to other pollutant emissions from the coal-fired power plant, CO2 reached up to 99.28%. Therefore, the control of CO2 emission from the coal-fired power plants was very important. Based on the BP neural network, the amount of CO2 emission from the generation side of coal-fired power plants was calculated via carbon balance method. The results showed that unit capacity, coal quality and unit operation load had great influence on the CO2 emission from coal-fired power plants in Guangdong Province. The use of high volatile and high heat value of coal also can reduce the CO2 emissions. What’s more, under higher operation load condition, the CO2 emissions of 1 kWh electric energy was less.
NASA Astrophysics Data System (ADS)
Wooster, M. J.; Freeborn, P. H.; Archibald, S.; Oppenheimer, C.; Roberts, G. J.; Smith, T. E. L.; Govender, N.; Burton, M.; Palumbo, I.
2011-11-01
Biomass burning emissions factors are vital to quantifying trace gas release from vegetation fires. Here we evaluate emissions factors for a series of savannah fires in Kruger National Park (KNP), South Africa using ground-based open path Fourier transform infrared (FTIR) spectroscopy and an IR source separated by 150-250 m distance. Molecular abundances along the extended open path are retrieved using a spectral forward model coupled to a non-linear least squares fitting approach. We demonstrate derivation of trace gas column amounts for horizontal paths transecting the width of the advected plume, and find for example that CO mixing ratio changes of ~0.01 μmol mol-1 [10 ppbv] can be detected across the relatively long optical paths used here. Though FTIR spectroscopy can detect dozens of different chemical species present in vegetation fire smoke, we focus our analysis on five key combustion products released preferentially during the pyrolysis (CH2O), flaming (CO2) and smoldering (CO, CH4, NH3) processes. We demonstrate that well constrained emissions ratios for these gases to both CO2 and CO can be derived for the backfire, headfire and residual smouldering combustion (RSC) stages of these savannah fires, from which stage-specific emission factors can then be calculated. Headfires and backfires often show similar emission ratios and emission factors, but those of the RSC stage can differ substantially. The timing of each fire stage was identified via airborne optical and thermal IR imagery and ground-observer reports, with the airborne IR imagery also used to derive estimates of fire radiative energy (FRE), allowing the relative amount of fuel burned in each stage to be calculated and "fire averaged" emission ratios and emission factors to be determined. These "fire averaged" metrics are dominated by the headfire contribution, since the FRE data indicate that the vast majority of the fuel is burned in this stage. Our fire averaged emission ratios and factors for CO2 and CH4 agree well with those from prior studies conducted in the same area using e.g. airborne plume sampling. We also concur with past suggestions that emission factors for formaldehyde in this environment appear substantially underestimated in widely used databases, but see no evidence to support suggestions by Sinha et al. (2003) of a major overestimation in the emission factor of ammonia in works such as Andreae and Merlet (2001) and Akagi et al. (2011). We also measure somewhat higher CO and NH3 emission ratios and factors than are usually reported for this environment, which is interpreted to result from the OP-FTIR ground-based technique sampling a greater proportion of smoke from smouldering processes than is generally the case with methods such as airborne sampling. Finally, our results suggest that the contribution of burning animal (elephant) dung can be a significant factor in the emissions characteristics of certain KNP fires, and that the ability of remotely sensed fire temperatures to provide information useful in tailoring modified combustion efficiency (MCE) and emissions factor estimates maybe rather limited, at least until the generally available precision of such temperature estimates can be substantially improved. One limitation of the OP-FTIR method is its ability to sample only near-ground level smoke, which may limit application at more intense fires where the majority of smoke is released into a vertically rising convection column. Nevertheless, even in such cases the method potentially enables a much better assessment of the emissions contribution of the RSC stage than is typically conducted currently.
46 CFR 161.002-2 - Types of fire-protective systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample extraction smoke detection systems, watchman's supervisory systems, and combinations of these systems. (b) Automatic fire detecting systems. For the purpose of this subpart, automatic fire and smoke detecting...
46 CFR 161.002-2 - Types of fire-protective systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample extraction smoke detection systems, watchman's supervisory systems, and combinations of these systems. (b) Automatic fire detecting systems. For the purpose of this subpart, automatic fire and smoke detecting...
Thermal energy storage for power generation applications
NASA Astrophysics Data System (ADS)
Drost, M. K.; Antoniak, Zen I.; Brown, D. R.
1990-03-01
Studies strongly indicate that the United States will face widespread electrical power constraints in the 1990s. In many cases, the demand for increased power will occur during peak and intermediate demand periods. While natural gas is currently plentiful and economically attractive for meeting peak and intermediate loads, the development of a coal-fired peaking option would give utilities insurance against unexpected supply shortages or cost increases. This paper discusses a conceptual evaluation of using thermal energy storage (TES) to improve the economics of coal-fired peak and intermediate load power generation. The use of TES can substantially improve the economic attractiveness of meeting peak and intermediate loads with coal-fired power generation. In this case, conventional pulverized coal combustion equipment is continuously operated to heat molten nitrate salt, which is then stored. During peak demand periods, hot salt is withdrawn from storage and used to generate steam for a Rankine steam power cycle. This allows the coal-fired salt heater to be approximately one-third the size of a coal-fired boiler in a conventional cycling plant. The general impact is to decouple the generation of thermal energy from its conversion to electricity. The present study compares a conventional cycling pulverized coal-fired power plant to a pulverized coal-fired plant using nitrate salt TES. The study demonstrates that a coal-fired salt heater is technically feasible and should be less expensive than a similar coal-fired boiler. The results show the use of nitrate salt TES reduced the levelized cost of power by between 5 and 24 percent, depending on the operating schedule.
NASA Astrophysics Data System (ADS)
Liao, Yanfen; Fang, Hailin; Zhang, Hengjin; Yu, Zhaosheng; Liu, Zhichao; Ma, Xiaoqian
2017-05-01
To meet with the demand of energy conservation and emission reduction policies, the method of life cycle assessment (LCA) was used to assess the feasibility of Hybrid Giant Napier (HGN) direct-fired power generation in this study. The entire life cycle is consisted of five stages (cultivation and harvesting, transportation, drying and comminuting, direct-fired power generation, constructing and decommissioning of biomass power plant). Analytical results revealed that to generate 10000kWh electricity, 10.925 t of customized HGN fuel (moisture content: 30 wt%) and 6659.430 MJ of energy were required. The total environmental impact potential was 0.927 PET2010 (person equivalents, targeted, in 2010) and the global warming (GW), acidification (AC), and nutrient (NE) emissions were 339.235 kg CO2-eq, 22.033 kg SO2-eq, and 25.486 kg NOx-eq respectively. The effect of AC was the most serious among all calculated category impacts. The energy requirements and environmental impacts were found to be sensitive to single yield, average transport distance, cutting frequency, and moisture content. The results indicated that HGN direct-fired power generation accorded well with Chinese energy planning; in addition, HGN proved to be a promising contribution to reducing non-renewable energy consumption and had encouraging prospects as a renewable energy plant.
Airborne In-Situ Trace Gas Measurements of Multiple Wildfires in California (2013-2014)
NASA Astrophysics Data System (ADS)
Iraci, L. T.; Yates, E. L.; Tanaka, T.; Roby, M.; Gore, W.; Clements, C. B.; Lareau, N.; Ambrosia, V. G.; Quayle, B.; Schroeder, W.
2014-12-01
Biomass burning emissions are an important source of a wide range of trace gases and particles that can impact local, regional and global air quality, climate forcing, biogeochemical cycles and human health. In the western US, wildfires dominate over prescribed fires, contributing to atmospheric trace gas budgets and regional and local air pollution. Limited sampling of emissions from wildfires means western US emission estimates rely largely on data from prescribed fires, which may not be a suitable proxy for wildfire emissions. We report here in-situ measurements of carbon dioxide, methane, ozone and water vapor from the plumes of a variety of wildfires sampled in California in the fire seasons of 2013 and 2014. Included in the analysis are the Rim Fire (August - October 2013, near Yosemite National Park), the Morgan Fire (September 2013, near Clayton, CA), and the El Portal Fire (July - August 2014, in Yosemite National Park), among others. When possible, fires were sampled on multiple days. Emission ratios and estimated emission factors will be presented and discussed in the context of fuel composition, plume structure, and fire phase. Correlations of plume chemical composition to MODIS/VIIRS Fire Radiative Power (FRP) and other remote sensing information will be explored. Furthermore, the role of plumes in delivery of enhanced ozone concentrations to downwind municipalities will be discussed.
Microbiological corrosion of ASTM SA105 carbon steel pipe for industrial fire water usage
NASA Astrophysics Data System (ADS)
Chidambaram, S.; Ashok, K.; Karthik, V.; Venkatakrishnan, P. G.
2018-02-01
The large number of metallic systems developed for last few decades against both general uniform corrosion and localized corrosion. Among all microbiological induced corrosion (MIC) is attractive, multidisciplinary and complex in nature. Many chemical processing industries utilizes fresh water for fire service to nullify major/minor fire. One such fire water service line pipe attacked by micro-organisms leads to leakage which is industrially important from safety point of view. Also large numbers of leakage reported in similar fire water service of nearby food processing plant, paper & pulp plant, steel plant, electricity board etc…In present investigation one such industrial fire water service line failure analysis of carbon steel line pipe was analyzed to determine the cause of failure. The water sample subjected to various chemical and bacterial analyses. Turbidity, pH, calcium hardness, free chlorine, oxidation reduction potential, fungi, yeasts, sulphide reducing bacteria (SRB) and total bacteria (TB) were measured on water sample analysis. The corrosion rate was measured on steel samples and corrosion coupon measurements were installed in fire water for validating non flow assisted localized corrosion. The sulphide reducing bacteria (SRB) presents in fire water causes a localized micro biological corrosion attack of line pipe.
Ecological and sampling constraints on defining landscape fire severity
Key, C.H.
2006-01-01
Ecological definition and detection of fire severity are influenced by factors of spatial resolution and timing. Resolution determines the aggregation of effects within a sampling unit or pixel (alpha variation), hence limiting the discernible ecological responses, and controlling the spatial patchiness of responses distributed throughout a burn (beta variation). As resolution decreases, alpha variation increases, extracting beta variation and complexity from the spatial model of the whole burn. Seasonal timing impacts the quality of radiometric data in terms of transmittance, sun angle, and potential contrast between responses within burns. Detection sensitivity candegrade toward the end of many fire seasons when low sun angles, vegetation senescence, incomplete burning, hazy conditions, or snow are common. Thus, a need exists to supersede many rapid response applications when remote sensing conditions improve. Lag timing, or timesince fire, notably shapes the ecological character of severity through first-order effects that only emerge with time after fire, including delayed survivorship and mortality. Survivorship diminishes the detected magnitude of severity, as burned vegetation remains viable and resprouts, though at first it may appear completely charred or consumed above ground. Conversely, delayed mortality increases the severity estimate when apparently healthy vegetation is in fact damaged by heat to the extent that it dies over time. Both responses dependon fire behavior and various species-specific adaptations to fire that are unique to the pre-firecomposition of each burned area. Both responses can lead initially to either over- or underestimating severity. Based on such implications, three sampling intervals for short-term burn severity are identified; rapid, initial, and extended assessment, sampled within about two weeks, two months, and depending on the ecotype, from three months to one year after fire, respectively. Spatial and temporal conditions of sampling strategies constrain data quality and ecological information obtained about fire severity. Though commonly overlooked, such considerations determine the objectives and hypotheses that are appropriate for each application, and are especially important when building comparative studies or long-term reference databases on fire severity.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-02
...-fired furnaces, Underwriters Laboratories (UL) Standard 727-1994, ``Standard for Safety for Oil-Fired... supplementary method called a catalog teardown (or ``virtual teardown'') uses published manufacturer catalogs... similar products and in manufacturer literature and information, to estimate the costs using virtual...
NASA Astrophysics Data System (ADS)
Bárcenas-Moreno, Gema; Zavala, Lorena; Jordan, Antonio; Bååth, Erland; Mataix-Beneyto, Jorge
2013-04-01
Plant communities can play an important role in fire severity and post-fire ecosystem recovery due to their role as combustible and different plant-soil microorganisms interactions. Possible differences induced by plant and microorganisms response after fire could affect the general ecosystem short and long-term response and its sustainability. The main objective of this work was the evaluation of the effect of wildfire on soil microbial abundance, activity and diversity in two different plant communities associated to different altitudes in Sierra Nevada National Park (Granada, Spain). Samples were collected in two areas located on the Sierra Nevada Mountain between 1700 and 2000 m above sea level which were affected by a large wildfire in 2005. Two samplings were carried out 8 and 20 months after fire and samples were collected in both burned and unburned (control) zones in each plant community area. Area A is located at 1700m and it is formed by Quercus rotundifolia forest while area B is located at 2000 m altitude and is composed of alpine vegetation formed by creeping bearing shrubs. Microbial biomass measured by Fumigation-Extraction method followed the same trend in both areas showing slight and no significant differences between burned and unburned area during the study period while viable and cultivable bacteria abundance were markedly higher in fire affected samples than in the control ones in both samplings. Viable and cultivable filamentous fungi had different behavior depending of plant vegetation community studied showing no differences between burned and unburned area in area A while was significantly higher in burned samples than in the control ones in area B. Microbial activity monitoring with soil microbial respiration appears to had been affected immediately after fire since microbial respiration was lower in burned samples from area A than in unburned one only 8 months after fire and no significant differences were observed between burned and unburned samples in area B. Soil microbial community composition studied by Principal Component Analyses (PCA) of the PLFA pattern revealed both fire and seasonal effects. General overview of the results could lead to think in a slight negative or even positive effect of fire on soil microbial parameters studied, mainly in zone B. Nevertheless if we calculate the ratio between C-biomass and organic-C we find lower ratio in fire-affected samples than in the control ones in both areas, showing the most marked effect on area B which remain with this tendency 20 months after fire. Acknowledgements: This research was supported by the CICYT co-financed FEDER project CGL2006-11107-C02-01/BOS. We are grateful for the Sierra Nevada National Park support during the study.
Measurements for the BETC in-situ combustion experiment. [Post test surveys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wayland, J.R.; Bartel, L.C.
The Bartlesville Energy Technology Center (BETC) in situ combustion pilot project near Bartlette, Kansas, was studied using controlled source audio-magnetotelluric (CSAMT) mapping, thermal gravimetric analysis (TGA), conventional geophysical logging and modeling of the fireflood. Measurements of formation resistivity changes induced by in situ combustion indicate that CSAMT resistivity maps should show an increase in apparent resistivity. The substantial decrease of apparent resistivity measured within the five spot pattern indicated a complex sequence of events. Using the results from the CSAMT surveys the fire front was located and posttest core samples were obtained. The posttest core samples were examined using TGAmore » techniques, and using information from combustion tube runs as standards, the location of the fire front in the core samples from the posttest holes was inferred. Models of the reservoir in situ combustion process were developed to help analyze the field results. The combustion kinematics, when used in conjunction with CSAMT and TGA techniques, indicated that considerable bypass of injected air occurred with an influx of brine into previously burned zones. This experiment offered an opportunity to integrate several new techniques into a systematic study of a difficult problem.« less
Climate change and fire danger rating in the Northern Rockies
Faith Ann Heinsch; Charles W. McHugh
2010-01-01
Studies have indicated that changes in wildland fire activity are, at least in part, a product of climate change. Fire danger indices, driven by climatology, should reflect these changes. Energy Release Component (ERC) is considered to be an effective indicator of drought conditions and seasonal drying of forest fuels and is often used in fire management planning....
High-resolution infrared thermography for capturing wildland fire behaviour - RxCADRE 2012
Joseph J. O’Brien; E. Louise Loudermilk; Benjamin Hornsby; Andrew T. Hudak; Benjamin C. Bright; Matthew B. Dickinson; J. Kevin Hiers; Casey Teske; Roger D. Ottmar
2016-01-01
Wildland fire radiant energy emission is one of the only measurements of combustion that can be made at wide spatial extents and high temporal and spatial resolutions. Furthermore, spatially and temporally explicit measurements are critical for making inferences about fire effects and useful for examining patterns of fire spread. In this study we describe our...
Remote sensing fire and fuels in southern California
Philip Riggan; Lynn Wolden; Bob Tissell; David Weise; J. Coen
2011-01-01
Airborne remote sensing at infrared wavelengths has the potential to quantify large-fire properties related to energy release or intensity, residence time, fuel-consumption rate, rate of spread, and soil heating. Remote sensing at a high temporal rate can track fire-line outbreaks and acceleration and spotting ahead of a fire front. Yet infrared imagers and imaging...
Impact of Released Fual Moisture on Atmospheric Dynamics
Brian E. Potter
2003-01-01
A common component of fire incident reports and prescribed burn preparations is an estimate of the energy that was or will be released by the fire. Typically, this is based on the energy released by combustion of the fuel load, reduced to account for the energy that is required to evaporate moisture in the fuel materials. (e.g., Byram 1959, Anderson 1968, Simard et al...
NASA Astrophysics Data System (ADS)
Abney, Rebecca B.; Sanderman, Jonathan; Johnson, Dale; Fogel, Marilyn L.; Berhe, Asmeret Asefaw
2017-11-01
Catchments impacted by wildfire typically experience elevated rates of post-fire erosion and formation and deposition of pyrogenic carbon (PyC). To better understand the role of erosion in post-fire soil carbon dynamics, we determined distribution of soil organic carbon in different chemical fractions before and after the Gondola fire in South Lake Tahoe, CA. We analyzed soil samples from eroding and depositional landform positions in control and burned plots pre- and post-wildfire (in 2002, 2003, and 10-years post-fire in 2013). We determined elemental concentrations, stable isotope compositions, and biochemical composition of organic matter (OM) using mid-infrared (MIR) spectroscopy for all of the samples. A subset of samples was analyzed by 13C cross polarization magic angle spinning nuclear magnetic resonance spectroscopy (CPMAS 13C-NMR). We combined the MIR and CPMAS 13C-NMR data in the Soil Carbon Research Program partial least squares regression model to predict distribution of soil carbon into three different fractions: 1) particulate, humic, and resistant organic matter fractions representing relatively fresh larger pieces of OM, 2) fine, decomposed OM, and 3) pyrogenic C, respectively. Samples from the post-fire eroding landform position showed no major difference in soil organic carbon (SOC) fractions one year post-fire. The depositional samples, however, had increased concentrations of all SOC fractions, particularly the fraction that resembles PyC, one year post-fire (2002), which had a mean of 160 g/kg compared with burned hillslope soils, which had 84 g/kg. The increase in all SOC fractions in the post-fire depositional landform position one year post-fire indicates significant lateral mobilization of the eroded PyC. In addition, our NMR analyses revealed a post-fire increase in both the aryl and O-aryl carbon compounds in the soils from the depositional landform position, indicating increases in soil PyC concentrations post-fire. After 10 years, the C concentration from all three fractions declined in the depositional landform position to below pre-fire levels likely due to further erosion or elevated rates of decomposition. Thus, we found, at this site, that both fire and erosion exert significant influence on the distribution of PyC throughout a landscape and its long-term fate in the soil system.
Influence of the processing route of porcelain/Ti-6Al-4V interfaces on shear bond strength.
Toptan, Fatih; Alves, Alexandra C; Henriques, Bruno; Souza, Júlio C M; Coelho, Rui; Silva, Filipe S; Rocha, Luís A; Ariza, Edith
2013-04-01
This study aims at evaluating the two-fold effect of initial surface conditions and dental porcelain-to-Ti-6Al-4V alloy joining processing route on the shear bond strength. Porcelain-to-Ti-6Al-4V samples were processed by conventional furnace firing (porcelain-fused-to-metal) and hot pressing. Prior to the processing, Ti-6Al-4V cylinders were prepared by three different surface treatments: polishing, alumina or silica blasting. Within the firing process, polished and alumina blasted samples were subjected to two different cooling rates: air cooling and a slower cooling rate (65°C/min). Metal/porcelain bond strength was evaluated by shear bond test. The data were analyzed using one-way ANOVA followed by Tuckey's test (p<0.05). Before and after shear bond tests, metallic surfaces and metal/ceramic interfaces were examined by Field Emission Gun Scanning Electron Microscope (FEG-SEM) equipped with Energy Dispersive X-Ray Spectroscopy (EDS). Shear bond strength values of the porcelain-to-Ti-6Al-4V alloy interfaces ranged from 27.1±8.9MPa for porcelain fused to polished samples up to 134.0±43.4MPa for porcelain fused to alumina blasted samples. According to the statistical analysis, no significant difference were found on the shear bond strength values for different cooling rates. Processing method was statistically significant only for the polished samples, and airborne particle abrasion was statistically significant only for the fired samples. The type of the blasting material did not cause a statistically significant difference on the shear bond strength values. Shear bond strength of dental porcelain to Ti-6Al-4V alloys can be significantly improved from controlled conditions of surface treatments and processing methods. Copyright © 2013 Elsevier Ltd. All rights reserved.
Post-fire regeneration across a fire severity gradient in the southern Cascades
Justin Crotteau; Morgan Varner; Martin Ritchie
2012-01-01
Large scale, high-severity fires are increasing in the western United States. Despite this trend, there have been few studies investigating post-fire tree regeneration. We established a study in the footprint of the 2000 Storrie Fire, a 23,000 ha wildfire that occurred in northern California, USA. We used a stratified sampling design to quantify post-fire vegetation...
Gas emissions, minerals, and tars associated with three coal fires, Powder River Basin, USA.
Engle, Mark A; Radke, Lawrence F; Heffern, Edward L; O'Keefe, Jennifer M K; Hower, James C; Smeltzer, Charles D; Hower, Judith M; Olea, Ricardo A; Eatwell, Robert J; Blake, Donald R; Emsbo-Mattingly, Stephen D; Stout, Scott A; Queen, Gerald; Aggen, Kerry L; Kolker, Allan; Prakash, Anupma; Henke, Kevin R; Stracher, Glenn B; Schroeder, Paul A; Román-Colón, Yomayra; ter Schure, Arnout
2012-03-15
Ground-based surveys of three coal fires and airborne surveys of two of the fires were conducted near Sheridan, Wyoming. The fires occur in natural outcrops and in abandoned mines, all containing Paleocene-age subbituminous coals. Diffuse (carbon dioxide (CO(2)) only) and vent (CO(2), carbon monoxide (CO), methane, hydrogen sulfide (H(2)S), and elemental mercury) emission estimates were made for each of the fires. Additionally, gas samples were collected for volatile organic compound (VOC) analysis and showed a large range in variation between vents. The fires produce locally dangerous levels of CO, CO(2), H(2)S, and benzene, among other gases. At one fire in an abandoned coal mine, trends in gas and tar composition followed a change in topography. Total CO(2) fluxes for the fires from airborne, ground-based, and rate of fire advancement estimates ranged from 0.9 to 780mg/s/m(2) and are comparable to other coal fires worldwide. Samples of tar and coal-fire minerals collected from the mouth of vents provided insight into the behavior and formation of the coal fires. Published by Elsevier B.V.
Influence of firing time and framework thickness on veneered Y-TZP discs curvature.
Jakubowicz-Kohen, Boris D; Sadoun, Michaël J; Douillard, Thierry; Mainjot, Amélie K
2014-02-01
The objective of the present work was to study the curvature of very thinly, veneered Y-TZP discs of different framework thicknesses submitted to different firing times. Fifteen 20-mm-wide Y-TZP discs were produced in three different thicknesses: 0.75, 1, 1.5mm. One disc from each group was left unveneered while the others were layered with a 0.1mm veneering ceramic layer. All discs underwent five firing cycles for a total cumulative firing time of 30 min, 1, 2, 5 and 10h at 900°C. The curvature profile was measured using a profilometer after the veneering process and after each firing cycle respectively. A fitted curve was then used to estimate the, curvature radius. The coefficient of thermal expansion (CTE) measurements were taken on veneering, ceramic and Y-TZP beam samples that underwent the same firing schedule. Those data were used to calculate the curvature generated by CTE variations over firing time. All bilayered samples exhibited a curvature that increased over firing time inversely to framework thickness. However non-veneered samples did not exhibit any curvature modification. The results of the present study reveal that even a very thin veneer layer (0.1mm) can induce a significant curvature of Y-TZP discs. The dilatometric results showed that Tg and CTE, variations are not sufficient to explain this curvature. A chemical-induced zirconia volume, augmentation located at the framework sub-surface near the interface could explain the sample, curvature and its increase with firing time. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
10 CFR 1042.215 - Membership practices of certain organizations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Section 1042.215 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION ON THE BASIS OF SEX IN..., YWCA, Girl Scouts, Boy Scouts, and Camp Fire Girls. These Title IX regulations do not apply to the... (YWCA), the Girl Scouts, the Boy Scouts, and Camp Fire Girls. (c) Voluntary youth service organizations...
10 CFR 1042.215 - Membership practices of certain organizations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Section 1042.215 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION ON THE BASIS OF SEX IN..., YWCA, Girl Scouts, Boy Scouts, and Camp Fire Girls. These Title IX regulations do not apply to the... (YWCA), the Girl Scouts, the Boy Scouts, and Camp Fire Girls. (c) Voluntary youth service organizations...
10 CFR 1042.215 - Membership practices of certain organizations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Section 1042.215 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION ON THE BASIS OF SEX IN..., YWCA, Girl Scouts, Boy Scouts, and Camp Fire Girls. These Title IX regulations do not apply to the... (YWCA), the Girl Scouts, the Boy Scouts, and Camp Fire Girls. (c) Voluntary youth service organizations...
10 CFR 1042.215 - Membership practices of certain organizations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Section 1042.215 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION ON THE BASIS OF SEX IN..., YWCA, Girl Scouts, Boy Scouts, and Camp Fire Girls. These Title IX regulations do not apply to the... (YWCA), the Girl Scouts, the Boy Scouts, and Camp Fire Girls. (c) Voluntary youth service organizations...
10 CFR 1042.215 - Membership practices of certain organizations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Section 1042.215 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) NONDISCRIMINATION ON THE BASIS OF SEX IN..., YWCA, Girl Scouts, Boy Scouts, and Camp Fire Girls. These Title IX regulations do not apply to the... (YWCA), the Girl Scouts, the Boy Scouts, and Camp Fire Girls. (c) Voluntary youth service organizations...
40 CFR 63.7575 - What definitions apply to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... having the primary purpose of recovering thermal energy in the form of steam or hot water. Controlled... the energy assessment. Electric utility steam generating unit (EGU) means a fossil fuel-fired... for sale. A fossil fuel-fired unit that cogenerates steam and electricity and supplies more than one...
40 CFR 63.7575 - What definitions apply to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... having the primary purpose of recovering thermal energy in the form of steam or hot water. Controlled... the energy assessment. Electric utility steam generating unit (EGU) means a fossil fuel-fired... for sale. A fossil fuel-fired unit that cogenerates steam and electricity and supplies more than one...
Feasibility of a small central cogenerated energy facility: Energy management memorandum
NASA Astrophysics Data System (ADS)
Porter, R. N.
1982-10-01
The thermal economic feasibility of a small cogenerated energy facility designed to serve several industries in the Stockyards area was investigated. Cogeneration options included two dual fuel diesels and two gas turbines, all with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired boiler cases, also low sulphur coal and municipal refuse. For coal and refuse, the option of steam only without cogeneration was also assessed. The fired boiler cogeneration systems employed back pressure steam turbines. The refuse fired cases utilized electrical capacities, 8500 to 52,400 lbm/hr and 0 to 9.9 MW (e), respectively. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which was displaced was sold to Commonwealth Edison Company under PURPA (Public Utility Regulatory Policies Act). The facility was operated by a mutually owned corporation formed by the cogenerated power users.
Effects of a fire alarm strobe light on fecal corticosterone metabolite concentrations in mice.
Godfrey, Denice; Silverman, Jerald
2009-02-01
The type and location of fire alarms are important considerations in animal facility design. The Guide for the Care and Use of Laboratory Animals recommends minimizing animal exposure to such alarms. Nevertheless, it is often necessary to maintain fire alarms within animal housing or procedural areas. The authors exposed male mice to the flashing strobe light component of a standard fire alarm and evaluated mouse fecal corticosterone concentration, which is known to be an indicator of stress. Mice were exposed to the strobe light for 5 min during either the light or the dark phase of the light:dark cycle. The authors collected fecal samples every 6 h for 24 h before exposing mice to the alarm and every 6 h for 24 h after exposure. Fecal samples taken before exposure (baseline samples) showed a normal circadian pattern of corticosterone metabolite excretion. In fecal samples taken after mice were exposed to the fire alarm, metabolite concentrations did not significantly differ from baseline concentrations over time.
C. Yue; P. Ciais; P. Cadule; K. Thonicke; S. Archibald; B. Poulter; W. M. Hao; S. Hantson; F. Mouillot; P. Friedlingstein; F. Maignan; N. Viovy
2014-01-01
Fire is an important global ecological process that influences the distribution of biomes, with consequences for carbon, water, and energy budgets. Therefore it is impossible to appropriately model the history and future of the terrestrial ecosystems and the climate system without including fire. This study incorporates the process-based prognostic fire module SPITFIRE...
Hoffman, Ray J.; Ferreira, Rodger F.
1976-01-01
Following two forest fires in the Roaring River drainage basin, Kings Canyon National Park, Calif., water samples were collected from May to July 1974 to determine water-quality changes resulting from the fires. Field measurements included alkalinity , pH, specific conductance, temperature, and discharge. Samples were analyzed in the laboratory for major dissolved chemical constituents, selected plant nutrients, trace metals, suspended sediment, total organic carbon, and seston. Periphytic algae and benthic invertebrate samples were collected. A noticeable increase in the concentration of nitrogen was found in Roaring River immediately downstream from the Moraine Creek fire. The increase in the concentration of inorganic nitrogen compounds, however, was not great enough to pose a serious threat to the aquatic ecosystem. High total organic nitrogen concentrations may have been due, in part, to factors other than the effect of fire. The results of other water-quality measurements were typical of dilute Sierra Nevada streams and indicate that Roaring River was not adversely affected by the fires. (Woodard-USGS)
NASA Astrophysics Data System (ADS)
Merino, Agustin; Fonturbel, M. Teresa; Vega, Jose A.
2015-04-01
Severe wildfires can cause drastic changes in SOM content and quality with important implications for soil conservation and global C balance. Soil heating usually leads to loss of the most labile SOM compounds (e.g. carbohydrates, lipids and peptides) and to generation of aromatic substances. However, these fire-related damages are not uniform over large areas, because of the spatial heterogeneity of different factors such as fire type and environmental conditions. Rapid diagnosis of soil burn severity is required to enable the design of emergency post-fire rehabilitation treatments. The study was conducted in soils from NW Spain, an Atlantic-climate zone that is particularly prone to wildfires. Intact soil cores (forest floor and uppermost mineral soil layer) were taken from a soil developed under granitic rock and subjected to experimental burning (in a bench positioned at the outlet of a wind tunnel). Soil temperature during fire was monitorised and five visual levels of soil burn severity (SBS) were recorded immediately after fire. Solid-state 13C CP-MAS NMR spectroscopy analyses were performed in an Agilent (Varian) VNMRS-500-WB spectrometer. The samples were analyzed by differential scanning calorimetry and thermogravimetry (TGA/DSC, Mettler-Toledo Intl. Inc.). The analyses were performed with 4 mg of samples placed in open aluminium pans under dry air (flow rate, 50 mL-1) and at a scanning rate of 10 °C min-1. The temperature ranged between 50 and 600 °C. In the organic layer, the temperature reached during fire influenced the formation and characteristics of charred material. These materials showed an increasing degree of carbonization/aromatization in relation to the increase of temperature during burning. Burning also led to compounds of higher thermal recalcitrance (increases in T50 values -the temperature at which 50% of the energy stored in SOM is released-). However, values recorded in some samples were lower than those measured in highly polycondensed aromatic compounds. In the mineral soil, large reductions in SOM content were found in both moderate and high SBS (up to 70 %), whereas important effects on SOM quality were only associated with high SBS. NMR analysis revealed these changes as losses of O-alkyl, alkyl and carboxylic structures and increases of the aromatic structures (up to 50 %). In both organic and mineral soils the DSC analysis revealed decreased combustion heat released up to 375 °C, and increased T50. Relationships between thermal properties and chemical-shift regions in the NMR helped provide a better understanding of SOM quality after wildfire. The results also show that thermal analysis can be used as a rapid tool to assess the different degrees of SOM degradation, in areas where the complex heterogeneity of the fire damage requires different emergency post-fire rehabilitation treatments.
Hasani, F; Shala, F; Xhixha, G; Xhixha, M K; Hodolli, G; Kadiri, S; Bylyku, E; Cfarku, F
2014-12-01
The energy production in Kosovo depends primarily on lignite-fired power plants. During coal combustion, huge amounts of fly ash and bottom ash are generated, which may result in enriched natural radionuclides; therefore, these radionuclides need to be investigated to identify the possible processes that may lead to the radiological exposure of workers and the local population. Lignite samples and NORMs of fly ash and bottom ash generated in lignite-fired power plants in Kosovo are analyzed using a gamma-ray spectrometry method for the activity concentration of natural radionuclides. The average activity concentrations of (40)K, (226)Ra and (232)Th in lignite are found to be 36 ± 8 Bq kg(-1), 9 ± 1 Bq kg(-1) and 9 ± 3 Bq kg(-1), respectively. Indications on the occurrence and geochemical behavior of uranium in the lignite matrix are suggested. The activity concentrations of natural radionuclides in fly ash and bottom ash samples are found to be concentrated from 3 to 5 times that of the feeding lignite. The external gamma-ray absorbed dose rate and the activity concentration index are calculated to assess the radiological hazard arising from ash disposal and recycling in the cement industry. Copyright © 2014 Elsevier Ltd. All rights reserved.
Atmospheric conditions related to blowup fires
George M. Byram
1954-01-01
Occasionally a forest fire burns with an intensity that seems far out of proportion to apparent burning conditions. Sometimes it multiplies its rate of energy output many times in a short space of time. Although infrequent, these unusual fires have over a long period of time been responsible for the major loss of life in forest fires and a large part of the losses in...
Predicting behavior and size of crown fires in the northern Rocky Mountains
Richard C. Rothermel
1991-01-01
Describes methods for approximating behavior and size of a wind-driven crown fire in mountainous terrain. Covers estimation of average rate of spread, energy release from tree crowns and surface fuel, fireline intensity, flame length, and unit area power of the fire and ambient wind. Plume-dominated fires, which may produce unexpectedly fast spread rates even with low...
A simple physical model for forest fire spread
E. Koo; P. Pagni; J. Woycheese; S. Stephens; D. Weise; J. Huff
2005-01-01
Based on energy conservation and detailed heat transfer mechanisms, a simple physical model for fire spread is presented for the limit of one-dimensional steady-state contiguous spread of a line fire in a thermally-thin uniform porous fuel bed. The solution for the fire spread rate is found as an eigenvalue from this model with appropriate boundary conditions through a...
Cool echidnas survive the fire.
Nowack, Julia; Cooper, Christine Elizabeth; Geiser, Fritz
2016-04-13
Fires have occurred throughout history, including those associated with the meteoroid impact at the Cretaceous-Palaeogene (K-Pg) boundary that eliminated many vertebrate species. To evaluate the recent hypothesis that the survival of the K-Pg fires by ancestral mammals was dependent on their ability to use energy-conserving torpor, we studied body temperature fluctuations and activity of an egg-laying mammal, the echidna (Tachyglossus aculeatus), often considered to be a 'living fossil', before, during and after a prescribed burn. All but one study animal survived the fire in the prescribed burn area and echidnas remained inactive during the day(s) following the fire and substantially reduced body temperature during bouts of torpor. For weeks after the fire, all individuals remained in their original territories and compensated for changes in their habitat with a decrease in mean body temperature and activity. Our data suggest that heterothermy enables mammals to outlast the conditions during and after a fire by reducing energy expenditure, permitting periods of extended inactivity. Therefore, torpor facilitates survival in a fire-scorched landscape and consequently may have been of functional significance for mammalian survival at the K-Pg boundary. © 2016 The Author(s).
NASA Astrophysics Data System (ADS)
Wentworth, Gregory R.; Aklilu, Yayne-abeba; Landis, Matthew S.; Hsu, Yu-Mei
2018-04-01
During May 2016 a very large boreal wildfire burned throughout the Athabasca Oil Sands Region (AOSR) in central Canada, and in close proximity to an extensive air quality monitoring network. This study examines speciated 24-h integrated polycyclic aromatic hydrocarbon (PAH) and volatile organic compound (VOC) measurements collected every sixth day at four and seven sites, respectively, from May to August 2016. The sum of PAHs (ΣPAH) was on average 17 times higher in fire-influenced samples (852 ng m-3, n = 8), relative to non-fire influenced samples (50 ng m-3, n = 64). Diagnostic PAH ratios in fire-influenced samples were indicative of a biomass burning source, whereas ratios in June to August samples showed additional influence from petrogenic and fossil fuel combustion. The average increase in the sum of VOCs (ΣVOC) was minor by comparison: 63 ppbv for fire-influenced samples (n = 16) versus 46 ppbv for non-fire samples (n = 90). The samples collected on August 16th and 22nd had large ΣVOC concentrations at all sites (average of 123 ppbv) that were unrelated to wildfire emissions, and composed primarily of acetaldehyde and methanol suggesting a photochemically aged air mass. Normalized excess enhancement ratios (ERs) were calculated for 20 VOCs and 23 PAHs for three fire influenced samples, and the former were generally consistent with previous observations. To our knowledge, this is the first study to report ER measurements for a number of VOCs and PAHs in fresh North American boreal wildfire plumes. During May the aged wildfire plume intercepted the cities of Edmonton (∼380 km south) or Lethbridge (∼790 km south) on four separate occasions. No enhancement in ground-level ozone (O3) was observed in these aged plumes despite an assumed increase in O3 precursors. In the AOSR, the only daily-averaged VOCs which approached or exceeded the hourly Alberta Ambient Air Quality Objectives (AAAQOs) were benzene (during the fire) and acetaldehyde (on August 16th and 22nd). Implications for local and regional air quality as well as suggestions for supplemental air monitoring during future boreal fires, are also discussed.
Guo, Yang; Tian, Jinping; Chertow, Marian; Chen, Lujun
2016-10-03
Mitigating greenhouse gas (GHG) emissions in China's industrial sector is crucial for addressing climate change. We developed a vintage stock model to quantify the GHG mitigation potential and cost effectiveness in Chinese eco-industrial parks by targeting energy infrastructure with five key measures. The model, integrating energy efficiency assessments, GHG emission accounting, cost-effectiveness analyses, and scenario analyses, was applied to 548 units of energy infrastructure in 106 parks. The results indicate that two measures (shifting coal-fired boilers to natural gas-fired boilers and replacing coal-fired units with natural gas combined cycle units) present a substantial potential to mitigate GHGs (42%-46%) compared with the baseline scenario. The other three measures (installation of municipal solid waste-to-energy units, replacement of small-capacity coal-fired units with large units, and implementation of turbine retrofitting) present potential mitigation values of 6.7%, 0.3%, and 2.1%, respectively. In most cases, substantial economic benefits also can be achieved by GHG emission mitigation. An uncertainty analysis showed that enhancing the annual working time or serviceable lifetime levels could strengthen the GHG mitigation potential at a lower cost for all of the measures.
Toxicity of pyrolysis gases from wood
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Huttlinger, N. V.; Oneill, B. A.; Kourtides, D. A.; Parker, J. A.
1977-01-01
The toxicity of the pyrolysis gases from nine wood samples was investigated. The samples of hardwoods were aspen poplar, beech, yellow birch, and red oak. The samples of softwoods were western red cedar, Douglas fir, western hemlock, eastern white pine, and southern yellow pine. There was no significant difference between the wood samples under rising temperature conditions, which are intended to simulate a developing fire, or under fixed temperature conditions, which are intended to simulate a fully developed fire. This test method is used to determine whether a material is significantly more toxic than wood under the preflashover conditions of a developing fire.
Chen, Ting Y; Zhang, Die; Dragomir, Andrei; Akay, Yasemin; Akay, Metin
2011-05-01
We investigated the influence of nicotine exposure and prefrontal cortex (PFC) transections on ventral tegmental areas (VTA) dopamine (DA) neurons' firing activities using a time-frequency method based on the continuous wavelet transform (CWT). Extracellular single-unit neural activity was recorded from DA neurons in the VTA area of rats. One group had their PFC inputs to the VTA intact, while the other group had the inputs to VTA bilaterally transected immediate caudal to the PFC. We hypothesized that the systemic nicotine exposure will significantly change the energy distribution in the recorded neural activity. Additionally, we investigated whether the loss of inputs to the VTA caused by the PFC transection resulted in the cancellation of the nicotine' effect on the neurons' firing patterns. The time-frequency representations of VTA DA neurons firing activity were estimated from the reconstructed firing rate histogram. The energy contents were estimated from three frequency bands, which are known to encompass the significant modes of operation of DA neurons. Our results show that systemic nicotine exposure disrupts the energy distribution in PFC-intact rats. Particularly, there is a significant increase in energy contents of the 1-1.5 Hz frequency band. This corresponds to an observed increase in the firing rate of VTA DA neurons following nicotine exposure. Additionally, our results from PFC-transected rats show that there is no change in the energy distribution of the recordings after systemic nicotine exposure. These results indicate that the PFC plays an important role in affecting the activities of VTA DA neurons and that the CWT is a useful method for monitoring the changes in neural activity patterns in both time and frequency domains.
Executive roundtable on coal-fired generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2009-09-15
Power Engineering magazine invited six industry executives from the coal-fired sector to discuss issues affecting current and future prospects of coal-fired generation. The executives are Tim Curran, head of Alstom Power for the USA and Senior Vice President and General Manager of Boilers North America; Ray Kowalik, President and General Manager of Burns and McDonnell Energy Group; Jeff Holmstead, head of Environmental Strategies for the Bracewell Giuliani law firm; Jim Mackey, Vice President, Fluor Power Group's Solid Fuel business line; Tom Shelby, President Kiewit Power Inc., and David Wilks, President of Energy Supply for Excel Energy Group. Steve Blankinship, themore » magazine's Associate Editor, was the moderator. 6 photos.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akagi, Sheryl; Burling, Ian R.; Mendoza, Albert
We report trace-gas emission factors from three pine-understory prescribed fires in South Carolina, U.S. measured during the fall of 2011. The fires were an attempt to simulate high-intensity burns and the fuels included mature pine stands not frequently subjected to prescribed fire that were lit following a sustained period of drought. In this work we focus on the emission factor measurements made using a fixed open-path gas analyzer Fourier transform infrared (FTIR) system. We compare these emission factors with those measured using a roving, point sampling, land-based FTIR and an airborne FTIR that were deployed on the same fires. Wemore » also compare to emission factors measured by a similar open-path FTIR system deployed on savanna fires in Africa. The data suggest that the method in which the smoke is sampled can strongly influence the relative abundance of the emissions that are observed. The airborne FTIR probed the bulk of the emissions, which were lofted in the convection column and the downwind chemistry while the roving ground-based point sampling FTIR measured the contribution of individual residual smoldering combustion fuel elements scattered throughout the burn site. The open-path FTIR provided a fixed path-integrated sample of emissions produced directly upwind mixed with emissions that were redirected by wind gusts, or right after ignition and before the adjacent plume achieved significant vertical development. It typically probed two distinct combustion regimes, “flaming-like” (immediately after adjacent ignition) and “smoldering-like”, denoted “early” and “late”, respectively. The calculated emission factors from open-path measurements were closer to the airborne than to the point measurements, but this could vary depending on the calculation method or from fire to fire given the changing MCE and dynamics over the duration of a typical burn. The emission factors for species whose emissions are not highly fuel dependent (e.g. CH4 and CH3OH) from all three systems can be plotted versus modified combustion efficiency and fit to a single consistent trend suggesting that differences between the systems for these species may be mainly due to the unique mix of flaming and smoldering that each system sampled. For other more fuel dependent species, the different fuels sampled also likely contributed to platform differences in emission factors. The path-integrated sample of the ground-level smoke layer adjacent to the fire provided by the open-path measurements is important for estimating fire-line exposure to smoke for wildland fire personnel. We provide a table of estimated fire-line exposures for numerous known air toxics based on synthesizing results from several studies. Our data suggest that peak exposures are more likely to challenge permissible exposure limits for wildland fire personnel than shift-average exposures.« less
NASA Astrophysics Data System (ADS)
Vasterling, Margarete; Schloemer, Stefan; Fischer, Christian; Ehrler, Christoph
2010-05-01
Spontaneous combustion of coal and resulting coal fires lead to very high temperatures in the subsurface. To a large amount the heat is transferred to the surface by convective and conductive transport inducing a more or less pronounced thermal anomaly. During the past decade satellite-based infrared-imaging (ASTER, MODIS) was the method of choice for coal fire detection on a local and regional scale. However, the resolution is by far too low for a detailed analysis of single coal fires which is essential prerequisite for corrective measures (i.e. fire fighting) and calculation of carbon dioxide emission based on a complex correlation between energy release and CO2 generation. Consequently, within the framework of the Sino-German research project "Innovative Technologies for Exploration, Extinction and Monitoring of Coal Fires in Northern China", a new concept was developed and successfully tested. An unmanned aerial vehicle (UAV) was equipped with a lightweight camera for thermografic (resolution 160 by 120 pixel, dynamic range -20 to 250°C) and for visual imaging. The UAV designed as an octocopter is able to hover at GPS controlled waypoints during predefined flight missions. The application of a UAV has several advantages. Compared to point measurements on the ground the thermal imagery quickly provides the spatial distribution of the temperature anomaly with a much better resolution. Areas otherwise not accessible (due to topography, fire induced cracks, etc.) can easily be investigated. The results of areal surveys on two coal fires in Xinjiang are presented. Georeferenced thermal and visual images were mosaicked together and analyzed. UAV-born data do well compared to temperatures measured directly on the ground and cover large areas in detail. However, measuring surface temperature alone is not sufficient. Simultaneous measurements made at the surface and in roughly 15cm depth proved substantial temperature gradients in the upper soil. Thus the temperature measured at the surface underestimates the energy emitted by the subsurface coal fire. In addition, surface temperature is strongly influenced by solar radiation and the prevailing ambient conditions (wind, temperature, humidity). As a consequence there is no simple correlation between surface and subsurface soil temperature. Efforts have been made to set up a coupled energy transport and energy balance model for the near surface considering thermal conduction, solar irradiation, thermal radiative energy and ambient temperature so far. The model can help to validate space-born and UAV-born thermal imagery and link surface to subsurface temperature but depends on in-situ measurements for input parameter determination and calibration. Results obtained so far strongly necessitate the integration of different data sources (in-situ / remote; point / area; local / medium scale) to obtain a reliable energy release estimation which is then used for coal fire characterization.
NASA Astrophysics Data System (ADS)
Kohl, L.; Chan, A. W. H.; Cooke, C. A.; Hustins, S.; Jackson, B.; Wang, S.; Jing, X.; Meng, M.
2017-12-01
The Horse River Fire in May 2016 forced the evacuation of 88,000 Fort McMurray residents, and led to the destruction of over 2000 houses. After re-entry to homes, there is significant concern about exposures to residual fire-derived contaminants in residential houses. Wildfire research, however, provides little guidance on how long ashes and pollutants persist in household dust after major fires. The FACET project studies the chemistry and toxicology of samples of urban and forest ashes and airborne particles collected during the fire, as well as over 500 house dust samples collected in July 2017 (14 months after the fire). Here we present results on the chemical composition of the urban and forest ash samples collected during the fire along with initial results from house dust samples. Wildfire ashes contained elevated concentrations of polycyclic aromatic hydrocarbons (PAH), heavy metals, and dioxin like compounds (DLC). Relative to EPA reference doses, As and Sb constitute the greatest non-carcinogenic health hazard, whereas PAHs Benzo(a)pyrene and Indeno(1,2,3-cd)pyrene are the most relevant carcinogens. Ashes from urban locations contained higher concentrations of heavy metals and DLC than samples collected from forested areas outside of the City of Fort McMurray. Urban samples furthermore had a greater potential for generating oxidative stress than rural samples, as determined by dithiothreitol (DTT) consumption assays. The oxidative potential was positively correlated to Al, Cu, As, and V concentrations. Airborne particulate matter samples from the smoke plume contained consistent concentrations of levoglucosan (99 ± 5 mg g-1), along with other tracers for biomass burning (free lignin monomers, retene). Together these results will serve as proxies for understanding the contribution and the persistence of fire-derived pollutants in house dust in Fort McMurray homes.
Soil carbon in Australian fire-prone forests determined by climate more than fire regimes.
Sawyer, Robert; Bradstock, Ross; Bedward, Michael; Morrison, R John
2018-10-15
Knowledge of global C cycle implications from changes to fire regime and climate are of growing importance. Studies on the role of the fire regime in combination with climate change on soil C pools are lacking. We used Bayesian modelling to estimate the soil % total C (% C Tot ) and % recalcitrant pyrogenic C (% RPC) from field samples collected using a stratified sampling approach. These observations were derived from the following scenarios: 1. Three fire frequencies across three distinctive climate regions in a homogeneous dry sclerophyll forest in south-eastern Australia over four decades. 2. The effects of different fire intensity combinations from successive wildfires. We found climate had a stronger effect than fire frequency on the size of the estimated mineral soil C pool. The largest soil C pool was estimated to occur under a wet and cold (WC) climate, via presumed effects of high precipitation, an adequate growing season temperature (i.e. resulting in relatively high NPP) and winter conditions sufficiently cold to retard seasonal soil respiration rates. The smallest soil C pool was estimated in forests with lower precipitation but warmer mean annual temperature (MAT). The lower precipitation and higher temperature was likely to have retarded NPP and litter decomposition rates but may have had little effect on relative soil respiration. Small effects associated with fire frequency were found, but both their magnitude and direction were climate dependent. There was an increase in soil C associated with a low intensity fire being followed by a high intensity fire. For both fire frequency and intensity the response of % RPC mirrored that of % C Tot : i.e. it was effectively a constant across all combinations of climate and fire regimes sampled. Copyright © 2018. Published by Elsevier B.V.
The effect of the fires on gypseous soil properties: changes of the hydrology and splash resistance.
NASA Astrophysics Data System (ADS)
León, J.; Seeger, M.; Echeverría, M.; Badía, D.; Peters, P.
2012-04-01
Mediterranean ecosystems have been severely affected by fires in the last decades. Due to social and economical changes, wildfires have caused hydrological and geomorphologic changes to be more pronounced, resulting in enhanced soil erosion. Soil heating caused by fires affects soil aggregates stability, water infiltration and may generate hydrophobicity. In order to understand how wildfire affects soil hydrological behavior in general, and splash and runoff processes in particular, of gypsum soils,it is advantageous to use a rainfall simulator. In August 2009 a large forest fire affected 6700 ha in Remolinos (NW Zaragoza, Spain). The area is covered by shrubs such as gorse (Genista scorpius L.), broom (Retama sphaerocarpa L.) and rosemary (Rosmarinus officinalis L.), and with small areas occupied by Aleppo pine (Pinus halepensis Mill) and Kermes evergreen-oak (Quercus coccifera L.). This region has a semarid Mediterranean climate, with an average annual rainfall ca 560 mm and a mean annual temperature of 12.5°C, resulting in an estimated climatic water deficit of ca. 400mm. The relief consists of stepped slopes (200-748 m), on two different types of soil have developed: Renzic Phaeozem, on limestone, and Haplic Gypsisol, on gypsum (IUSS, 2006). Within this study, we wanted to investigate the differences in affection by fire of the different soil types, as it may be caused by different fire intensities. Therefore, both soil types were sampled after fire. Also, similar locations were sampled which were not affected by the wildfires. With this, we could differentiate 4 treatments: burnt and unburnt pine forest and burnt and unburnt shrub on gypseous soils. We designed a set of lab experiments to elucidate the effect of heat on soil composition, aggregate stability, and splash susceptibility. Samples were taken using cylinders of 5 cm depth. Under laboratory conditions were measured pH, CE, organic matter (OM), soil aggregates stability (SAS), bulk density, porosity and mineralogical changes, using 5 subsamples of each treatment. The samples were heated at different temperatures (105 °C and 205 °C) in an oven for 30 min to simulated different fire intensities, for comparison. A set was only air dried (35 °C). To study the splash effect of the gypsum soils were use small scale rainfall simulator in laboratory, applying a rainfall intensity of 47 mm h-1 during 20 min, resulting in a kinetic energy of 8.94 J m-2 mm-1. The gross loss of material of each of the undisturbed samples was measured after 20 minutes of simulation. The pH is slightly alkaline and oscillates between 7.93-8.32, depending on soil cover type, and is highest under burnt pine forest. The EC (2.08-5.01 mS cm-1) did not change after heating of the unburnt shrub cover, but in the soil under burnt pine forest, the EC was lowered with increasing temperature. The OM content is moderate (3.73-4.85 %), and higher on burnt soils, increasing also with an increase of treatment temperature. The SAS (43.17-75.92 %) is strongly depending on the temperature applied, and was found higher on the burnt surfaces. The gypsum content of the soils is moderate to high (11.30-39.58 %), but decreases with the treatment at 205°C. The soil loss by splash vaied between 0.9 to 2.8 g (per sample) after 20 min of rainfall simulation. Highest losses were found on burnt surfaces. The results show that fire and temperature affects not all characteristics of soils. Acknowledgements: This research was supported by the Ministry of Science and Innovation BES-2008-003056, the CETSUS project (CGL2007-66644-C04-04/HIDCLI) and the Geomorphology and Global Change Research Group (D.G.A., 2011). The Spanish Army has supported this work at the San Gregorio CENAF.
Importance of hard coal in electricity generation in Poland
NASA Astrophysics Data System (ADS)
Plewa, Franciszek; Strozik, Grzegorz
2017-11-01
Polish energy sector is facing a number of challenges, in particular as regards the reconstruction of production potential, diversification of energy sources, environmental issues, adequate fuels supplies and other. Mandatory implementation of Europe 2020 strategy in terms of “3x20” targets (20% reduction of greenhouse gases, 20% of energy from renewable sources, and 20% increase of efficiency in energy production) requires fast decision, which have to be coordinated with energetic safety issues, increasing demands for electric energy, and other factors. In Poland almost 80% of power is installed in coal fired power plants and energy from hard coals is relatively less expensive than from other sources, especially renewable. The most of renewable energy sources power plants are unable to generate power in amounts which can be competitive with coal fires power stations and are highly expensive, what leads o high prices of electric energy. Alternatively, new generation of coal fired coal power plants is able to significantly increase efficiency, reduce carbon dioxide emission, and generate less expensive electric power in amounts adequate to the demands of a country.
PCM/wood composite to store thermal energy in passive building envelopes
NASA Astrophysics Data System (ADS)
Barreneche, C.; Vecstaudza, J.; Bajare, D.; Fernandez, A. I.
2017-10-01
The development of new materials to store thermal energy in a passive building system is a must to improve the thermal efficiency by thermal-regulating the indoor temperatures. This fact will deal with the reduction of the gap between energy supply and energy demand to achieve thermal comfort in building indoors. The aim of this work was to test properties of novel PCM/wood composite materials developed at Riga Technical University. Impregnation of PCM (phase change material) in wood increases its thermal mass and regulates temperature fluctuations during day and night. The PCM used are paraffin waxes (RT-21 and RT-27 from Rubitherm) and the wood used was black alder, the most common wood in Latvia. The PCM distribution inside wood sample has been studied as well as its thermophysical, mechanical and fire reaction properties. Developed composite materials are promising in the field of energy saving in buildings.
Feasibility of a medium-size central cogenerated energy facility, energy management memorandum
NASA Astrophysics Data System (ADS)
Porter, R. W.
1982-09-01
The thermal-economic feasibility was studied of a medium-size central cogenerated energy facility designed to serve five varied industries. Generation options included one dual-fuel diesel and one gas turbine, both with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired-boiler cases, also low-sulphur coal and municipal refuse. The fired-boiler cogeneration systems employed back-pressure steam turbines. For coal and refuse, the option of steam only without cogeneration was also assessed. The refuse-fired cases utilized modular incinerators. The options provided for a wide range of steam and electrical capacities. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which could be displaced was assumed sold to Commonwealth Edison Company under PURPA (Public Utility Regulator Policies Act). The facility was assumed operated by a mutually owned corporation formed by the cogenerated power users. The economic analysis was predicted on currently applicable energy-investment tax credits and accelerated depreciation for a January 1985 startup date. Based on 100% equity financing, the results indicated that the best alternative was the modular-incinerator cogeneration system.
Djarwanto; Tachibana, S
2010-06-15
This research was conducted in the aim of preventing wild fire through reducing potential energy source to become in situ fertilizer. To prevent forest fires by reducing wood waste using lignocellulose-degrading fungi, six fungal isolates were tested for lignin and cellulose-degrading activity with Acacia mangium leaves and twigs over a period of 1 to 3 months. The fungi degraded 8.9-27.1% of the lignin and 14-31% of the holocellulose. The degradation rate varied depending on the fungal species. An increase in incubation time tended to decrease the amounts of holocellulose and lignin. However, the hot water soluble tended to increase following a longer incubation period. From the results obtained here, more time was needed to degrade lignin rather than other components in the sample.
Johnson, Lane B; Kipfmueller, Kurt F
2016-06-01
We reconstructed fire occurrence near a fur-trade era canoe travel corridor (used ca. 1780-1802) in the Quetico-Superior region west of Lake Superior to explore the possibility of human influence on pre-fire suppression rates of fire occurrence. Our research objectives were to (1) examine the spatial and temporal patterns of fire in the study area, (2) test fires' strength of association with regional drought, and (3) assess whether reconstructed fire frequencies could be explained by observed rates of lightning fire ignition over the modern period of record. We developed a 420-year fire history for the eastern portion of Lac La Croix in the Boundary Waters Canoe Area Wilderness (BWCAW). Seventy-one fire-scarred samples were collected from remnant Pinus resinosa Ait. (red pine) stumps and logs from thirteen distinct island and three mainland forest stands. Collectively these samples contained records of 255 individual fire scars representing 79 fire events from 1636 to 1933 (study area mean fire intervals [MFI] 3.8 yr). Reconstructed fires were spatially and temporally asynchronous and not strongly associated with regional drought (P > 0.05). When compared to the conservative, tree-ring reconstructed estimate of historical fire occurrence and modern lightning-caused fires (1929-2012), a noticeable change in the distribution and frequency of fires within the study area was evident with only two lightning-ignited island fires since 1934 in the study area. Our results suggest a high likelihood that indigenous land use contributed to surface fire ignitions within our study area and highlights the importance of examining the potential effects of past indigenous land use when determining modern approaches to fire and wilderness management in fire-adapted ecosystems.
Collender, Mark A; Doherty, Kevin A J; Stanton, Kenneth T
2017-01-01
Following a shooting incident where a vehicle is used to convey the culprits to and from the scene, both the getaway car and the firearm are often deliberately burned in an attempt to destroy any forensic evidence which may be subsequently recovered. Here we investigate the factors that influence the ability to make toolmark identifications on ammunition discharged from pistols recovered from such car fires. This work was carried out by conducting a number of controlled furnace tests in conjunction with real car fire tests in which three 9mm semi-automatic pistols were burned. Comparisons between pre-burn and post burn test fired ammunition discharged from these pistols were then performed to establish if identifications were still possible. The surfaces of the furnace heated samples and car fire samples were examined following heating/burning to establish what factors had influenced their surface morphology. The primary influence on the surfaces of the furnace heated and car fire samples was the formation of oxide layers. The car fire samples were altered to a greater extent than the furnace heated samples. Identifications were still possible between pre- and post-burn discharged cartridge cases, but this was not the case for the discharged bullets. It is suggested that the reason for this is a difference between the types of firearms discharge-generated toolmarks impressed onto the base of cartridge cases compared to those striated along the surfaces of bullets. It was also found that the temperatures recorded in the front foot wells were considerably less than those recorded on top of the rear seats during the car fires. These factors should be assessed by forensic firearms examiners when performing casework involving pistols recovered from car fires. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.
Alternative fuels in fire debris analysis: biodiesel basics.
Stauffer, Eric; Byron, Doug
2007-03-01
Alternative fuels are becoming more prominent on the market today and, soon, fire debris analysts will start seeing them in liquid samples or in fire debris samples. Biodiesel fuel is one of the most common alternative fuels and is now readily available in many parts of the United States and around the world. This article introduces biodiesel to fire debris analysts. Biodiesel fuel is manufactured from vegetable oils and/or animal oils/fats. It is composed of fatty acid methyl esters (FAMEs) and is sold pure or as a blend with diesel fuel. When present in fire debris samples, it is recommended to extract the debris using passive headspace concentration on activated charcoal, possibly followed by a solvent extraction. The gas chromatographic analysis of the extract is first carried out with the same program as for regular ignitable liquid residues, and second with a program adapted to the analysis of FAMEs.
Sampling High-Altitude and Stratified Mating Flights of Red Imported Fire Ant
USDA-ARS?s Scientific Manuscript database
With the exception of an airplane equipped with nets, no method has been developed that successfully samples red imported fire ant, Solenopsis invicta Buren, sexuals in mating/dispersal flights throughout their potential altitudinal trajectories. We developed and tested a method for sampling queens ...
Pan, Ying; Wang, Wei; Liu, Longxiang; Ge, Hua; Song, Lei; Hu, Yuan
2017-08-15
Bio-based and phosphorus-free coating was fabricated by layer-by-layer assembly method to obtain the flame retardant cotton fabric. For the first time, the modified cotton fabrics were prepared by utilizing positively charged polyethylenimine and negatively charged alginate together with subsequent crosslinking of barium, nickel and cobalt ions. Scanning electron microscopy and energy-dispersive X-ray demonstrated that the metal ions crosslinked coating was successfully constructed on the substrate. The thermal stability and flame retardancy were investigated by thermogravimetric analysis (TGA) and horizontal flame tests. TGA results showed that the degradation of the coated cotton fabrics were retarded at high temperature and the char residue of the cotton fabrics were improved after covered with the barium, nickel and cobalt ions crosslinked coatings. Furthermore, the fire resistance of cotton-Ba sample was enhanced significantly compared with the untreated sample, as evidenced by the obvious reduction (28%) of flame spread rate and complete char residue. Finally, the washing durability of coating on the fabric was enhanced after metal ions crosslinked with alginate based coating. Copyright © 2017. Published by Elsevier Ltd.
Code of Federal Regulations, 2014 CFR
2014-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2012 CFR
2012-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2014 CFR
2014-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2012 CFR
2012-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2014 CFR
2014-07-01
... fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to recirculating... the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming-cycle unit: (1...
Code of Federal Regulations, 2013 CFR
2013-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2012 CFR
2012-07-01
... fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to recirculating... the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming-cycle unit: (1...
Code of Federal Regulations, 2013 CFR
2013-07-01
... fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to recirculating... the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming-cycle unit: (1...
Code of Federal Regulations, 2013 CFR
2013-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Actuated Recoil Absorbing Mounting System for use with an Underwater Gun
1998-03-31
fire supercavitating bullets, requires that 20 the new projectile launchers be tested. The firing of projectile 21 launchers involving a high...of projectile launcher 12 includes an underwater gun 15 that fires supercavitating bullets underwater and has a high 16 discharge energy. However
NASA Astrophysics Data System (ADS)
Potter, S.; Solvik, K.; Erb, A.; Goetz, S. J.; Johnstone, J. F.; Mack, M. C.; Randerson, J. T.; Roman, M. O.; Schaaf, C. L.; Turetsky, M. R.; Veraverbeke, S.; Wang, Z.; Rogers, B. M.
2017-12-01
Boreal forest dynamics including succession, composition, carbon cycling, and surface-atmosphere energy exchanges are largely driven by fire. In Alaska and Canada, burned area and fire frequency have increased since the 1970s, and are projected to continue increasing into the 21st century. In contrast to other biomes, alterations to surface albedo from fires in North American boreal forests are one of the primary feedbacks to climate. Understanding how altered fire regimes impact vegetation composition and energy budgets is therefore critical to forecasting regional and global climate change. High-severity fires cause winter and spring albedo to increase due to increased snow exposure and replacement of evergreen conifers by deciduous broadleaf trees. Although summer albedo decreases initially due to the deposition of black carbon and charred surfaces, it typically increases for several decades thereafter when younger and brighter deciduous trees dominate. The net effect of these albedo changes is expected to result in substantive radiative cooling, but there has been little research to examine how albedo trajectories differ spatially and temporally as a result of differences in burn severity, species composition, topography, climate and soil properties, and what the associated implications for future energy balances are. Here we investigate drivers of post-fire monthly albedo trajectories across Canada and Alaska using a new Collection V006 500 m MODIS daily blue-sky albedo product and historical fires from the Canadian and Alaskan National Fire Databases. The impacts of varying fuel type, landscape position, soils, climate, and burn severity on monthly albedo trajectories are explored using a Random Forest model. This information is then used to predict long-term monthly albedo and radiative forcing for fires that occurred during the MODIS era (2001-2012). We find that higher severity burns in denser forests and environmental conditions that promote either deciduous vegetation or slower tree growth result in the largest increases in post fire albedo and radiative cooling. This understanding and our geospatial products may be relevant for management focused on limiting the climate impacts from intensifying boreal fire regimes.
Alternative approach for fire suppression of class A, B and C fires in gloveboxes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberger, Mark S; Tsiagkouris, James A
2011-02-10
Department of Energy (DOE) Orders and National Fire Protection Association (NFPA) Codes and Standards require fire suppression in gloveboxes. Several potential solutions have been and are currently being considered at Los Alamos National Laboratory (LANL). The objective is to provide reliable, minimally invasive, and seismically robust fire suppression capable of extinguishing Class A, B, and C fires; achieve compliance with DOE and NFPA requirements; and provide value-added improvements to fire safety in gloveboxes. This report provides a brief summary of current approaches and also documents the successful fire tests conducted to prove that one approach, specifically Fire Foe{trademark} tubes, ismore » capable of achieving the requirement to provide reliable fire protection in gloveboxes in a cost-effective manner.« less
Pratt, R Brandon; Jacobsen, Anna L; Ramirez, Aaron R; Helms, Anjel M; Traugh, Courtney A; Tobin, Michael F; Heffner, Marcus S; Davis, Stephen D
2014-03-01
We examined postfire regeneration of chaparral shrubs during an intense drought. This study focused on the demography and physiology of shrub species that resprout from a basal lignotuber following fire. We found significant levels of resprout mortality when intense drought occurred in the year following fire during the period of shrub recovery. Three of the seven sampled resprouting species had the greatest or near greatest levels of mortality ever recorded when compared to previous studies. Most shrub mortality occurred during the drought after individuals had resprouted (i.e. individuals survived fire, resprouted and then subsequently died). Physiological measurements of species with high mortality suggested that resprout stems were highly embolized and xylem hydraulic conductivities were close to zero during the peak of the drought. In addition, lignotubers of two of the three species experiencing high mortality were depleted of starch. Population densities of most shrub species declined after the drought compared with their prefire levels, with the exception of one drought tolerant obligate seeding species. Resprouting shrub species may deplete their carbohydrate reserves during the resprouting process, making them particularly vulnerable to drought because of the need to transpire water to acquire the CO2 that is used to supply energy to a large respiring root system. Drought appears to interact with fire by altering postfire shrub recovery and altering species abundances and composition of chaparral communities. © 2013 John Wiley & Sons Ltd.
Basunia, S; Landsberger, S
2001-10-01
Pantex firing range soil samples were analyzed for Pb, Cu, Sb, Zn, and As. One hundred ninety-seven samples were collected from the firing range and vicinity area. There was a lack of knowledge about the distribution of Pb in the firing range, so a random sampling with proportional allocation was chosen. Concentration levels of Pb and Cu in the firing range were found to be in the range of 11-4675 and 13-359 mg/kg, respectively. Concentration levels of Sb were found to be in the range of 1-517 mg/kg. However, the Zn and As concentration levels were close to average soil background levels. The Sn concentration level was expected to be higher in the Pantex firing range soil samples. However, it was found to be below the neutron activation analysis (NAA) detection limit of 75 mg/kg. Enrichment factor analysis showed that Pb and Sb were highly enriched in the firing range with average magnitudes of 55 and 90, respectively. Cu was enriched approximately 6 times more than the usual soil concentration levels. Toxicity characteristic leaching procedure (TCLP) was carried out on size-fractionated homogeneous soil samples. The concentration levels of Pb in leachates were found to be approximately 12 times higher than the U.S. Environmental Protection Agency (EPA) regulatory concentration level of 5 mg/L. Sequential extraction (SE) was also performed to characterize Pb and other trace elements into five different fractions. The highest Pb fraction was found with organic matter in the soil.
Mercury pollution in vegetables, grains and soils from areas surrounding coal-fired power plants
NASA Astrophysics Data System (ADS)
Li, Rui; Wu, Han; Ding, Jing; Fu, Weimin; Gan, Lijun; Li, Yi
2017-05-01
Mercury contamination in food can pose serious health risks to consumers and coal-fired power plants have been identified as the major source of mercury emissions. To assess the current state of mercury pollution in food crops grown near coal-fired power plants, we measured the total mercury concentration in vegetables and grain crops collected from farms located near two coal-fired power plants. We found that 79% of vegetable samples and 67% of grain samples exceeded the PTWI's food safety standards. The mercury concentrations of soil samples were negatively correlated with distances from the studied coal-fired power plants, and the mercury contents in lettuce, amaranth, water spinach, cowpea and rice samples were correlated with the mercury contents in soil samples, respectively. Also, the mercury concentrations in vegetable leaves were much higher than those in roots and the mercury content of vegetable leaves decreased significantly after water rinses. Our calculation suggests that probable weekly intake of mercury for local residents, assuming all of their vegetables and grains are from their own farmland, may exceed the toxicologically tolerable values allowed, and therefore long-term consumptions of these contaminated vegetables and grains may pose serious health risks.
Williams, Mary R; Sigman, Michael E; Lewis, Jennifer; Pitan, Kelly McHugh
2012-10-10
A bayesian soft classification method combined with target factor analysis (TFA) is described and tested for the analysis of fire debris data. The method relies on analysis of the average mass spectrum across the chromatographic profile (i.e., the total ion spectrum, TIS) from multiple samples taken from a single fire scene. A library of TIS from reference ignitable liquids with assigned ASTM classification is used as the target factors in TFA. The class-conditional distributions of correlations between the target and predicted factors for each ASTM class are represented by kernel functions and analyzed by bayesian decision theory. The soft classification approach assists in assessing the probability that ignitable liquid residue from a specific ASTM E1618 class, is present in a set of samples from a single fire scene, even in the presence of unspecified background contributions from pyrolysis products. The method is demonstrated with sample data sets and then tested on laboratory-scale burn data and large-scale field test burns. The overall performance achieved in laboratory and field test of the method is approximately 80% correct classification of fire debris samples. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Mercury pollution in vegetables, grains and soils from areas surrounding coal-fired power plants
Li, Rui; Wu, Han; Ding, Jing; Fu, Weimin; Gan, Lijun; Li, Yi
2017-01-01
Mercury contamination in food can pose serious health risks to consumers and coal-fired power plants have been identified as the major source of mercury emissions. To assess the current state of mercury pollution in food crops grown near coal-fired power plants, we measured the total mercury concentration in vegetables and grain crops collected from farms located near two coal-fired power plants. We found that 79% of vegetable samples and 67% of grain samples exceeded the PTWI’s food safety standards. The mercury concentrations of soil samples were negatively correlated with distances from the studied coal-fired power plants, and the mercury contents in lettuce, amaranth, water spinach, cowpea and rice samples were correlated with the mercury contents in soil samples, respectively. Also, the mercury concentrations in vegetable leaves were much higher than those in roots and the mercury content of vegetable leaves decreased significantly after water rinses. Our calculation suggests that probable weekly intake of mercury for local residents, assuming all of their vegetables and grains are from their own farmland, may exceed the toxicologically tolerable values allowed, and therefore long-term consumptions of these contaminated vegetables and grains may pose serious health risks. PMID:28484233
46 CFR 164.006-4 - Inspection and testing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...
46 CFR 164.006-4 - Inspection and testing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...
46 CFR 164.006-4 - Inspection and testing.
Code of Federal Regulations, 2011 CFR
2011-10-01
... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...
46 CFR 164.006-4 - Inspection and testing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...
CHEMICAL AND PHYSICAL PROPERTIES OF EMISSIONS FROM KUWAITI OIL FIRES
After the Iraqi retreat from Kuwait in 1991, airborne sampling was conducted in the oil fire plumes near Kuwait City and ground-level samples were taken of the air within the city. or the airborne sampling, a versatile air pollution sampler was used to determine the SO2, elementa...
Wood products : thermal degradation and fire
R.H. White; M.A. Dietenberger
2001-01-01
Wood is a thermally degradable and combustible material. Applications range from a biomass providing useful energy to a building material with unique properties. Wood products can contribute to unwanted fires and be destroyed as well. Minor amounts of thermal degradation adversely affect structural properties. Therefore, knowledge of the thermal degradation and fire...
Warren E. Heilman; Xindi Bain
2013-01-01
Recent research suggests that high levels of ambient near-surface atmospheric turbulence are often associated with rapid and sometimes erratic wildland fire spread that may eventually lead to large burn areas. Previous research has also examined the feasibility of using near-surface atmospheric turbulent kinetic energy (TKEs) alone or in...
2003-07-01
Office Agency for Nuclear Projects Energy Agriculture Business & Industry Minerals Economic Development Tourism Fire Marshal Human Resources...Agriculture Business & Industry Minerals Economic Development Tourism Fire Marshal Human Resources A in Services Indian Commission Colorado...Data EIAP Environmental Impact Analysis Process EMCS Central Energy Management System ERP Environmental Restoration Program ESA Endangered
Burton, Carmen; Hoefen, Todd M.; Plumlee, Geoffrey S.; Baumberger, Katherine L.; Backlin, Adam R.; Gallegos, Elizabeth; Fisher, Robert N.
2016-01-01
Most research on the effects of wildfires on stream water quality has focused on suspended sediment and nutrients in streams and water bodies, and relatively little research has examined the effects of wildfires on trace elements. The purpose of this study was two-fold: 1) to determine the effect of the 2009 Station Fire in the Angeles National Forest northeast of Los Angeles, CA on trace element concentrations in streams, and 2) compare trace elements in post-fire stormflow water quality to criteria for aquatic life to determine if trace elements reached concentrations that can harm aquatic life. Pre-storm and stormflow water-quality samples were collected in streams located inside and outside of the burn area of the Station Fire. Ash and burned soil samples were collected from several locations within the perimeter of the Station Fire. Filtered concentrations of Fe, Mn, and Hg and total concentrations of most trace elements in storm samples were elevated as a result of the Station Fire. In contrast, filtered concentrations of Cu, Pb, Ni, and Se and total concentrations of Cu were elevated primarily due to storms and not the Station Fire. Total concentrations of Se and Zn were elevated as a result of both storms and the Station Fire. Suspended sediment in stormflows following the Station Fire was an important transport mechanism for trace elements. Cu, Pb, and Zn primarily originate from ash in the suspended sediment. Fe primarily originates from burned soil in the suspended sediment. As, Mn, and Ni originate from both ash and burned soil. Filtered concentrations of trace elements in stormwater samples affected by the Station Fire did not reach levels that were greater than criteria established for aquatic life. Total concentrations for Fe, Pb, Ni, and Zn were detected at concentrations above criteria established for aquatic life.
Burton, Carmen A.; Hoefen, Todd M.; Plumlee, Geoffrey S.; Baumberger, Katherine L.; Backlin, Adam R.; Gallegos, Elizabeth; Fisher, Robert N.
2016-01-01
Most research on the effects of wildfires on stream water quality has focused on suspended sediment and nutrients in streams and water bodies, and relatively little research has examined the effects of wildfires on trace elements. The purpose of this study was two-fold: 1) to determine the effect of the 2009 Station Fire in the Angeles National Forest northeast of Los Angeles, CA on trace element concentrations in streams, and 2) compare trace elements in post-fire stormflow water quality to criteria for aquatic life to determine if trace elements reached concentrations that can harm aquatic life. Pre-storm and stormflow water-quality samples were collected in streams located inside and outside of the burn area of the Station Fire. Ash and burned soil samples were collected from several locations within the perimeter of the Station Fire. Filtered concentrations of Fe, Mn, and Hg and total concentrations of most trace elements in storm samples were elevated as a result of the Station Fire. In contrast, filtered concentrations of Cu, Pb, Ni, and Se and total concentrations of Cu were elevated primarily due to storms and not the Station Fire. Total concentrations of Se and Zn were elevated as a result of both storms and the Station Fire. Suspended sediment in stormflows following the Station Fire was an important transport mechanism for trace elements. Cu, Pb, and Zn primarily originate from ash in the suspended sediment. Fe primarily originates from burned soil in the suspended sediment. As, Mn, and Ni originate from both ash and burned soil. Filtered concentrations of trace elements in stormwater samples affected by the Station Fire did not reach levels that were greater than criteria established for aquatic life. Total concentrations for Fe, Pb, Ni, and Zn were detected at concentrations above criteria established for aquatic life. PMID:27144270
Conceptual design of thermal energy storage systems for near-term electric utility applications
NASA Technical Reports Server (NTRS)
Hall, E. W.
1980-01-01
Promising thermal energy storage systems for midterm applications in conventional electric utilities for peaking power generation are evaluated. Conceptual designs of selected thermal energy storage systems integrated with conventional utilities are considered including characteristics of alternate systems for peaking power generation, viz gas turbines and coal fired cycling plants. Competitive benefit analysis of thermal energy storage systems with alternate systems for peaking power generation and recommendations for development and field test of thermal energy storage with a conventional utility are included. Results indicate that thermal energy storage is only marginally competitive with coal fired cycling power plants and gas turbines for peaking power generation.
Usefulness of fire ant genetics in insecticide efficacy trials
USDA-ARS?s Scientific Manuscript database
Mature fire ant colonies contain an average of 80,000 worker ants. For this study, eight fire ant workers were randomly sampled from each colony. DNA fingerprints for each individual ant were generated using 21 simple sequence repeats (SSR) markers that were developed from fire ant DNA by other lab...
NASA Astrophysics Data System (ADS)
Hudak, A. T.; Dickinson, M. B.; Kremens, R.; Loudermilk, L.; O'Brien, J.; Satterberg, K.; Strand, E. K.; Ottmar, R. D.
2013-12-01
Longleaf pine stand structure and function are dependent on frequent fires, so fire managers maintain healthy longleaf pine ecosystems by frequently burning surface fuels with prescribed fires. Eglin Air Force Base (AFB) in the Florida panhandle boasts the largest remnant of longleaf pine forest, providing a productive setting for fire scientists to make multi-scale measurements of fuels, fire behavior, and fire effects in collaboration with Eglin AFB fire managers. Data considered in this analysis were collected in five prescribed burn units: two forested units burned in 2011 and a forested unit and two grassland units burned in 2012. Our objective was to demonstrate the linear relationship between biomass and fire energy that has been shown in the laboratory, but using two independent remotely sensed airborne datasets collected at the unit level: 1) airborne lidar flown over the burn units immediately prior to the burns, and 2) thermal infrared image time series flown over the burn units at 2-3 minute intervals. Airborne lidar point cloud data were reduced to 3 m raster metrics of surface vegetation height and cover, which were in turn used to map surface fuel loads at 3 m resolution. Plot-based measures of prefire surface fuels were used for calibration/validation. Preliminary results based on 2011 data indicate airborne lidar can explain ~30% of variation in surface fuel loads. Multi-temporal thermal infrared imagery (WASP) collected at 3 m resolution were calibrated to units of fire radiative power (FRP), using simultaneous FRP measures from ground-based radiometers, and then temporally integrated to estimate fire radiative energy (FRE) release at the unit level. Prior to AGU, FRP and FRE will be compared to estimates of the same variables derived from ground-based FLIR thermal infrared imaging cameras, each deployed with a nadir view from a tripod, at three sites per burn unit. A preliminary proof-of-concept, comparing FRE derived from a tripod-based FLIR (3.2 MW), to another FLIR deployed with an oblique view from atop a 36 m boom lift (2.1 MW), demonstrated reasonable agreement. Unit-level estimates of FRE will also be compared to estimates of surface fuel consumption (~5 Mg/ha) that were summarized at the unit level from pre- and post-fire clip plots of surface fuel biomass. At AGU, we will also compare predictions of surface fuel loads to estimates of energy release, as mapped at 3 m resolution from these independent remotely sensed data sources. These results will serve to demonstrate our ability to remotely measure and relate fuel loads to fire behavior at a landscape level.
A barn caught fire at on Seerley Road, Indianapolis. Five storage drums believed to contain metallic potassium were involved in the fire. EPA will perform additional sampling as part of removal operations and safe offsite transportation.
Eppinger, Robert G.; Briggs, Paul H.; Brown, Zoe Ann; Crock, James G.; Meier, Allen; Theodorakos, Peter M.; Wilson, Stephen A.
2001-01-01
In 1996, the U.S. Geological Survey conducted a reconnaissance baseline geochemical study in central Idaho. The purpose of the baseline study was to establish a 'geochemical snapshot' of the area, as a datum for monitoring future change in the geochemical landscape, whether natural or human-induced. This report presents the methology, analytical results, and sample descriptions for water, sediment, and heavy-mineral concentrate samples collected during this geochemical investigation. In the summer of 2000, the Clear Creek, Little Pistol, and Shellrock wildfires swept across much of the area that was sampled. Thus, these data represent a pre-fire baseline geochemical dataset. A 2001 post- fire study is planned and will involve re-sampling of the pre-fire baseline sites, to allow for pre- and post-fire comparison.
Theory-Based Cartographic Risk Model Development and Application for Home Fire Safety.
Furmanek, Stephen; Lehna, Carlee; Hanchette, Carol
There is a gap in the use of predictive risk models to identify areas at risk for home fires and burn injury. The purpose of this study was to describe the creation, validation, and application of such a model using a sample from an intervention study with parents of newborns in Jefferson County, KY, as an example. Performed was a literature search to identify risk factors for home fires and burn injury in the target population. Obtained from the American Community Survey at the census tract level and synthesized to create a predictive cartographic risk model was risk factor data. Model validation was performed through correlation, regression, and Moran's I with fire incidence data from open records. Independent samples t-tests were used to examine the model in relation to geocoded participant addresses. Participant risk level for fire rate was determined and proximity to fire station service areas and hospitals. The model showed high and severe risk clustering in the northwest section of the county. Strongly correlated with fire rate was modeled risk; the best predictive model for fire risk contained home value (low), race (black), and non high school graduates. Applying the model to the intervention sample, the majority of participants were at lower risk and mostly within service areas closest to a fire department and hospital. Cartographic risk models were useful in identifying areas at risk and analyzing participant risk level. The methods outlined in this study are generalizable to other public health issues.
Integrated Sampling Strategy (ISS) Guide
Robert E. Keane; Duncan C. Lutes
2006-01-01
What is an Integrated Sampling Strategy? Simply put, it is the strategy that guides how plots are put on the landscape. FIREMONâs Integrated Sampling Strategy assists fire managers as they design their fire monitoring project by answering questions such as: What statistical approach is appropriate for my sample design? How many plots can I afford? How many plots do I...
46 CFR 164.007-9 - Procedure for approval.
Code of Federal Regulations, 2012 CFR
2012-10-01
.... (1) If the manufacturer desires to have the test conducted at some laboratory other than the National... sample or samples for the fire resistance test will be given at this time, together with the estimated...″×12″) sample and a 60 cm. × 60cm. (24″×24″) sample for each thickness and density proposed to the Fire...
46 CFR 164.007-9 - Procedure for approval.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... (1) If the manufacturer desires to have the test conducted at some laboratory other than the National... sample or samples for the fire resistance test will be given at this time, together with the estimated...″×12″) sample and a 60 cm. × 60cm. (24″×24″) sample for each thickness and density proposed to the Fire...
Large-Scale Spacecraft Fire Safety Tests
NASA Technical Reports Server (NTRS)
Urban, David; Ruff, Gary A.; Ferkul, Paul V.; Olson, Sandra; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Cowlard, Adam J.; Rouvreau, Sebastien; Minster, Olivier;
2014-01-01
An international collaborative program is underway to address open issues in spacecraft fire safety. Because of limited access to long-term low-gravity conditions and the small volume generally allotted for these experiments, there have been relatively few experiments that directly study spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample sizes and environment conditions typical of those expected in a spacecraft fire. The major constraint has been the size of the sample, with prior experiments limited to samples of the order of 10 cm in length and width or smaller. This lack of experimental data forces spacecraft designers to base their designs and safety precautions on 1-g understanding of flame spread, fire detection, and suppression. However, low-gravity combustion research has demonstrated substantial differences in flame behavior in low-gravity. This, combined with the differences caused by the confined spacecraft environment, necessitates practical scale spacecraft fire safety research to mitigate risks for future space missions. To address this issue, a large-scale spacecraft fire experiment is under development by NASA and an international team of investigators. This poster presents the objectives, status, and concept of this collaborative international project (Saffire). The project plan is to conduct fire safety experiments on three sequential flights of an unmanned ISS re-supply spacecraft (the Orbital Cygnus vehicle) after they have completed their delivery of cargo to the ISS and have begun their return journeys to earth. On two flights (Saffire-1 and Saffire-3), the experiment will consist of a flame spread test involving a meter-scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. On one of the flights (Saffire-2), 9 smaller (5 x 30 cm) samples will be tested to evaluate NASAs material flammability screening tests. The first flight (Saffire-1) is scheduled for July 2015 with the other two following at six-month intervals. A computer modeling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the first examination of fire behavior on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation.
Pyro-eco-hydrologic feedbacks and catchment co-evolution in fire-prone forested uplands
NASA Astrophysics Data System (ADS)
Sheridan, Gary; Inbar, Assaf; Lane, Patrick; Nyman, Petter
2017-04-01
The south east Australian forested uplands are characterized by complex and inter-correlated spatial patterns in standing biomass, soil depth/quality, and fire regimes, even within areas with similar rainfall, geology and catenary position. These system properties have traditionally been investigated independently, however recent research in the areas of post fire hydrology and erosion, and new insights into forest structure, fuel moisture, and flammability, suggest the presence of critical co-evolutionary feedbacks between fire, soils and vegetation that may explain the observed system states. To test this hypothesis we started with a published ecohydrologic model, modifying and extending the algorithms to capture feedbacks between hyrology and fire, and between fire, vegetation and soil production and erosion. The model was parameterized and calibrated with new data from instrumented forested hillslopes across energy and rainfall gradients generated by selecting sites with a range of aspect (energy) and elevation (rainall). The calibrated model was able to reasonably replicate the observed patterns of standing biomass, water balance, fire interval, and soil depth. The catchment co-evolution/feedback modelling approach to understanding patterns of vegetation, soils and fire regimes provides a promising new paradigm for predicting the response of forested se Australian catchments to declining rainfall and increasing temperatures under climate change.
Smędra-Kaźmirska, Anna; Barzdo, Maciej; Kędzierski, Maciej; Antoszczyk, Łukasz; Szram, Stefan; Berent, Jarosław
2013-09-01
Pursuant to the Polish Weapons and Ammunitions Law (Legal Gazette No 53/1999 item 549 with subsequent amendments), air guns with kinetic energy of the fired projectiles below 17 J are not regarded as weapons. The aim of the study was to assess the potential effect of shots caused by projectiles of various mass and structure fired from air guns with kinetic energy below 17 J on human soft tissues. As a model of soft tissue, we used 20% gelatin blocks. After shooting, we measured the depth of gelatin block penetration by pellets fired from various distances and compared these results with autopsy findings. The results demonstrated that examined pneumatic guns may cause serious injuries, including damage to the pleura, pericardium, liver, spleen, kidneys, femoral artery, and thoracic and abdominal aorta. Experiment shown that gelatin blocks do not reflect fully the properties of the human body. © 2013 American Academy of Forensic Sciences.
NASA Astrophysics Data System (ADS)
Zong, Y.; He, K.; Zhang, Q.; Hong, C.
2016-12-01
Coal has long been an important energy type of Beijing's energy consumption. Since 1998, to improve urban air quality, Beijing has vigorously promoted the structure optimization of energy consumption. Primary measures included the implementation of strict emission standards for coal-fired power plant boilers, subsidized replacement and after-treatment retrofit of coal-fired boilers, the mandatory application of low-sulfur coal, and the accelerated use of natural gas, imported electricity and other clean energy. This work attempts to assess the emission reduction benefits on measures of three sectors, including replacing with clean energy and application of end-of-pipe control technologies in power plants, comprehensive control on coal-fired boilers and residential heating renovation. This study employs the model of Multi-resolution Emission Inventory for China (MEIC) to quantify emission reductions from upfront measures. These control measures have effectively reduced local emissions of major air pollutants in Beijing. The total emissions of PM2.5, PM10, SO2 and NOX from power plants in Beijing are estimated to have reduced 14.5 kt, 23.7 kt, 45.0 kt and 7.6 kt from 1998 to 2013, representing reductions of 86%, 87%, 85% and 16%, respectively. Totally, 14.3 kt, 24.0 kt, 136 kt and 48.7kt of PM2.5, PM10, SO2 and NOX emissions have been mitigated due to the comprehensive control measures on coal-fired boilers from 1998 to 2013. Residential heating renovation projects by replacing coal with electricity in Beijing's conventional old house areas contribute to emission reductions of 630 t, 870 t, 2070 t and 790 t for PM2.5, PM10, SO2 and NOX, respectively.
Development and evaluation of the photoload sampling technique
Robert E. Keane; Laura J. Dickinson
2007-01-01
Wildland fire managers need better estimates of fuel loading so they can accurately predict potential fire behavior and effects of alternative fuel and ecosystem restoration treatments. This report presents the development and evaluation of a new fuel sampling method, called the photoload sampling technique, to quickly and accurately estimate loadings for six common...
Fire protection review revisit no. 2, Argonne National Laboratory, Argonne, Illinois
NASA Astrophysics Data System (ADS)
Dobson, P. H.; Earley, M. W.; Mattern, L. J.
1985-05-01
A fire protection survey was conducted at Argonne National Laboratory on April 1-5, 8-12, and April 29-May 2, 1985. The purpose was to review the facility fire protection program and to make recommendations or identify areas according to criteria established by the Department of Energy. There has been a substantial improvement in fire protection at this laboratory since the 1977 audit. Numerous areas which were previously provided with detection systems only have since been provided with automatic sprinkler protection. The following basic fire protection features are not properly controlled: (1) resealing wall and floor penetrations between fire areas after installation of services; (2) cutting and welding; and (3) housekeeping. The present Fire Department manpower level appears adequate to control a route fire. Their ability to adequately handle a high-challenge fire, or one involving injuries to personnel, or fire spread beyond the initial fire area is doubtful.
NASA Astrophysics Data System (ADS)
Kiefer, Michael T.; Zhong, Shiyuan; Heilman, Warren E.; Charney, Joseph J.; Bian, Xindi
2018-03-01
An improved understanding of atmospheric perturbations within and above a forest during a wildland fire has relevance to many aspects of wildland fires including fire spread, smoke transport and dispersion, and tree mortality. In this study, the ARPS-CANOPY model, a version of the Advanced Regional Prediction System (ARPS) model with a canopy parameterization, is utilized in a series of idealized numerical experiments to investigate the influence of vertical canopy structure on the atmospheric response to a stationary sensible heat flux at the ground ("fire heat flux"), broadly consistent in magnitude with the sensible heat flux from a low-intensity surface fire. Five vertical canopy structures are combined with five fire heat flux magnitudes to yield a matrix of 25 simulations. Analyses of the fire-heat-flux-perturbed u component of the wind, vertical velocity, kinetic energy, and temperature show that the spatial pattern and magnitude of the perturbations are sensitive to vertical canopy structure. Both vertical velocity and kinetic energy exhibit an increasing trend with increasing fire heat flux that is stronger for cases with some amount of overstory vegetation than cases with exclusively understory vegetation. A weaker trend in cases with exclusively understory vegetation indicates a damping of the atmospheric response to the sensible heat from a surface fire when vegetation is most concentrated near the surface. More generally, the results presented in this study suggest that canopy morphology should be considered when applying the results of a fire-atmosphere interaction study conducted in one type of forest to other forests with different canopy structures.
Pigments which reflect infrared radiation from fire
Berdahl, Paul H.
1998-01-01
Conventional paints transmit or absorb most of the intense infrared (IR) radiation emitted by fire, causing them to contribute to the spread of fire. The present invention comprises a fire retardant paint additive that reflects the thermal IR radiation emitted by fire in the 1 to 20 micrometer (.mu.m) wavelength range. The important spectral ranges for fire control are typically about 1 to about 8 .mu.m or, for cool smoky fires, about 2 .mu.m to about 16 .mu.m. The improved inventive coatings reflect adverse electromagnetic energy and slow the spread of fire. Specific IR reflective pigments include titanium dioxide (rutile) and red iron oxide pigments with diameters of about 1 .mu.m to about 2 .mu.m and thin leafing aluminum flake pigments.
LSA SAF Meteosat FRP products - Part 1: Algorithms, product contents, and analysis
NASA Astrophysics Data System (ADS)
Wooster, M. J.; Roberts, G.; Freeborn, P. H.; Xu, W.; Govaerts, Y.; Beeby, R.; He, J.; Lattanzio, A.; Fisher, D.; Mullen, R.
2015-11-01
Characterizing changes in landscape fire activity at better than hourly temporal resolution is achievable using thermal observations of actively burning fires made from geostationary Earth Observation (EO) satellites. Over the last decade or more, a series of research and/or operational "active fire" products have been developed from geostationary EO data, often with the aim of supporting biomass burning fuel consumption and trace gas and aerosol emission calculations. Such Fire Radiative Power (FRP) products are generated operationally from Meteosat by the Land Surface Analysis Satellite Applications Facility (LSA SAF) and are available freely every 15 min in both near-real-time and archived form. These products map the location of actively burning fires and characterize their rates of thermal radiative energy release (FRP), which is believed proportional to rates of biomass consumption and smoke emission. The FRP-PIXEL product contains the full spatio-temporal resolution FRP data set derivable from the SEVIRI (Spinning Enhanced Visible and Infrared Imager) imager onboard Meteosat at a 3 km spatial sampling distance (decreasing away from the west African sub-satellite point), whilst the FRP-GRID product is an hourly summary at 5° grid resolution that includes simple bias adjustments for meteorological cloud cover and regional underestimation of FRP caused primarily by underdetection of low FRP fires. Here we describe the enhanced geostationary Fire Thermal Anomaly (FTA) detection algorithm used to deliver these products and detail the methods used to generate the atmospherically corrected FRP and per-pixel uncertainty metrics. Using SEVIRI scene simulations and real SEVIRI data, including from a period of Meteosat-8 "special operations", we describe certain sensor and data pre-processing characteristics that influence SEVIRI's active fire detection and FRP measurement capability, and use these to specify parameters in the FTA algorithm and to make recommendations for the forthcoming Meteosat Third Generation operations in relation to active fire measures. We show that the current SEVIRI FTA algorithm is able to discriminate actively burning fires covering down to 10-4 of a pixel and that it appears more sensitive to fire than other algorithms used to generate many widely exploited active fire products. Finally, we briefly illustrate the information contained within the current Meteosat FRP-PIXEL and FRP-GRID products, providing example analyses for both individual fires and multi-year regional-scale fire activity; the companion paper (Roberts et al., 2015) provides a full product performance evaluation and a demonstration of product use within components of the Copernicus Atmosphere Monitoring Service (CAMS).
NASA Astrophysics Data System (ADS)
Soja, A. J.; Stocks, B. J.; Carr, R.; Pierce, R. B.; Natarajan, M.; Fromm, M.
2009-05-01
Current climate change scenarios predict increases in biomass burning in terms of increases in fire frequency, area burned, fire season length and fire season severity, particularly in boreal regions. Climate and weather control fire danger, which strongly influences the severity of fire events, and these in turn, feed back to the climate system through direct and indirect emissions, modifying cloud condensation nuclei and altering albedo (affecting the energy balance) through vegetative land cover change and deposition. Additionally, fire emissions adversely influence air quality and human health downwind of burning. The boreal zone is significant because this region stores the largest reservoir of terrestrial carbon, globally, and will experience climate change impacts earliest. Boreal biomass burning is an integral component to several of the primary goals of the ARCTAS (Arctic Research of the Composition of the Troposphere from Aircraft and Satellites) and ARCPAC (Aerosol, Radiation, and Cloud Processes affecting Arctic Climate) 2008 field campaigns, which include its implication for atmospheric composition and climate, aerosol radiative forcing, and chemical processes with a focus on ozone and aerosols. Both the spring and summer phases of ARCTAS and ARCPAC offered substantial opportunities for sampling fresh and aged biomass burning emissions. However, the extent to which spring biomass burning influenced arctic haze was unexpected, which could inform our knowledge of the formation of arctic haze and the early deposition of black carbon on the icy arctic surface. There is already evidence of increased extreme fire seasons that correlate with warming across the circumboreal zone. In this presentation, we discuss seasonal and annual fire activity and anomalies that relate to the ARCTAS and ARCPAC spring (April 1 - 20) and summer (June 18 - July 13) periods across Siberia and North America, with particular emphasis on fire danger and fire behavior as they relate to smoke emissions. Fire severity and subsequent emission levels are directly related to fire danger conditions, which reflect and incorporate both antecedent and current weather. In this century, it is predicted that fire regime increases will be the catalyst for ecosystem change, which will force ecosystems to move more rapidly towards a new equilibrium with climate. However, the reasons for ecosystem change are often accompanied by social and political drivers of land cover change, which complicate the relationship between fire and weather. For instance, since the collapse of the former Soviet Union, financial support for fire fighting is minimal, communal agricultural lands have been abandoned and a number of species are no longer protected (e.g. Saiga in Kalmykia), and each of these factors strongly influences vegetation cover and fire regimes, leading to a complicated interaction of processes that control fire and its affect on the larger environment.
20000G shock energy harvesters for gun-fired munition
NASA Astrophysics Data System (ADS)
Willemin, J.; Boisseau, S.; Olmos, L.; Gallardo, M.; Despesse, G.; Robert, T.
2016-11-01
This paper presents a 20000G shock energy harvester dedicated to gun-fired munitions and based on a mass-spring resonant structure coupled to a coil-magnet electromagnetic converter. The 20000G shock energy is firstly stored in the spring as elastic potential energy, released as mass-spring mechanical oscillations right after the shock and finally converted into electricity thanks to the coil-magnet transducer. The device has been modeled, sized to generate 200mJ in 150ms, manufactured and tested in a gun-fired munition. The prototype sizes 117cm3 and weighs 370g. 210mJ have been generated in a test bench and 140mJ in real conditions; this corresponds to a mean output power of 0.93W (7.9mW/cm3) and a maximum output power of 4.83W (41.3mW/cm3) right after the shock.
DOT National Transportation Integrated Search
2009-12-01
The formation of a fuel mist resulting from high shear stresses acting on the fuel during violent sloshing and tank rupture under the energy of a crash severely increases the occurrence and intensity of fires in transportation related accidents. In o...
Installation-Wide Energy Conservation Demonstration at Fort McClellan, Alabama
1988-11-01
Inefficient Electrical Motors 12 Dispensary Chiller Installation 12 Combustion Optimization of Gas-fired Heating Equipment 12 Infiltration Study of Family... Chiller Installation 34 5 FAMILY HOUSING .................................................... 37 Combustion Optimization of Gas-fired Heating...in Outdoor Air Ventilation 59 Replacement of Inefficient Electric Motors 59 Dispensary Chiller Installation 60 Combustion Optimization of Gas-fired
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-29
... Ignitibility of Exterior Wall Assemblies Using a Radiant Heat Energy Source. NFPA 269 Standard Test Method P... for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption... Plastic Insulation. NFPA 285 Standard Fire Test P Method for Evaluation of Fire Propagation...
Test Plan to Assess Fire Effects on the Function of an Engineered Surface Barrier
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, Anderson L.; Berlin, Gregory T.; Cammann, Jerry W.
2008-09-29
Wildfire is a frequent perturbation in shrub steppe ecosystems, altering the flora, fauna, atmosphere, and soil of these systems. Research on the fire effects has focused mostly on natural ecosystems with essentially no attention on engineered systems like surface barriers. The scope of the project is to use a simulated wildfire to induce changes in an engineered surface barrier and document the effects on barrier performance. The main objective is to quantify the effects of burning and the resulting post-fire conditions on alterations in soil physical properties; hydrologic response, particularly the water balance; geochemical properties; and biological properties. A secondarymore » objective is to use the lessons learned to maximize fire protection in the design of long-term monitoring systems based on electronic sensors. A simulated wildfire will be initiated, controlled and monitored at the 200-BP-1 barrier in collaboration with the Hanford Fire Department during the fall of 2008. The north half of the barrier will be divided into nine 12 x 12 m plots, each of which will be randomly assigned a fuel load of 2 kg m-2 or 4 kg m-2. Each plot will be ignited around the perimeter and flames allowed to carry to the centre. Any remaining unburned vegetation will be manually burned off using a drip torch. Progress of the fire and its effects will be monitored using point measurements of thermal, hydrologic, and biotic variables. Three measures of fire intensity will be used to characterize fire behavior: (1) flame height, (2) the maximum temperature at three vertical profile levels, and (3) total duration of elevated temperature at these levels. Pre-burn plant information, including species diversity, plant height, and canopy diameter will be measured on shrubs from the plots to be burned and from control plots at the McGee ranch. General assessments of shrub survival, recovery, and recruitment will be made after the fire. Near-surface soil samples will be collected pre- and post-burn to determine changes in the gravel content of the surface layer so as to quantify inflationary or deflationary responses to fire and to reveal the ability of the surface to resist post-fire erosive stresses. Measures of bulk density, water repellency, water retention, and hydraulic conductivity will be used to characterize changes in infiltration rates and water storage capacity following the fire. Samples will also be analyzed to quantify geochemical changes including changes in soil pH, cation exchange capacity, specific surface area, and the concentration of macro nutrients (e.g. N, P, K) and other elements such as Na, Mg, Ca, that are critical to the post-fire recovery revegetation. Soil CO2 emissions will be measured monthly for one year following the burn to document post-fire stimulation of carbon turnover and soil biogenic emissions. Surface and subsurface temperature measurements at and near monitoring installations will be used to document fire effects on electronic equipment. The results of this study will be used to bridge the gaps in knowledge on the effects of fire on engineered ecosystems (e.g. surface barriers), particularly the hydrologic and biotic characteristics that govern the water and energy balance. These results will also support the development of practical fire management techniques for barriers that are compatible with wildfire suppression strategies. Furthermore, lessons learned will be use to develop installation strategies needed to protect electronic monitoring equipment from the intense heat of fire and the potential damaging effects of smoke and fire extinguishing agents. Such information is needed to better understand long-term barrier performance under extreme conditions, especially if site maintenance and operational funding is lost for activities such as barrier revegetation.« less
A dendrochronological fire history of Opeongo lookout in Algonquin Park, Ontario
Richard P. Guyette; Daniel C. Dey
1995-01-01
Fire-scarred stumps and natural snags of red pine (Pinus resinosa Ait.) on a 70-m tall bluff along Costello Creek, 2 km south of Lake Opeongo, were dated using dendrochronological methods. A fire scar chronology was constructed from 18 of the red pine samples that contained 34 dated fire scars.
The effect of repeated firings on the color change and surface roughness of dental ceramics
Yılmaz, Kerem; Ozturk, Caner
2014-01-01
PURPOSE The color of the ceramic restorations is affected by various factors such as brand, thickness of the layered the ceramic, condensation techniques, smoothness of surface, number of firings, firing temperature and thickness of dentin. The aim of this study was to evaluate the color change and surface roughness in dental porcelain with different thicknesses during repeated firings. MATERIALS AND METHODS Disc-shaped (N=21) metal-ceramic samples (IPS Classic; Ivoclar Vivadent; Shaar, Liechtenstein) with different thickness were exposed to repeated firings. Color measurement of the samples was made using a colorimeter and profilometer was used to determine surface roughness. ANOVA and Tukey tests with repeated measurements were used for statistical analysis. RESULTS The total thickness of the ceramics which is less than 2 mm significantly have detrimental effect on the surface properties and color of porcelains during firings (P<.05). CONCLUSION Repeated firings have effects on the color change and surface roughness of the dental ceramics and should be avoided. PMID:25177475
Gas Fride Heat Pumps : The Present and Future
NASA Astrophysics Data System (ADS)
Kurosawa, Shigekichi; Ogura, Masao
In japan techniques for saving energy is an important goal since energy resources such as oil and nuclear power are limited. Recently gas fired absorption heat pumps and gas engine driven heat pumps have been installed in facilifies such as hotels, swimming pools and offices.
In this article recent techniques, applications and future aspects for gas fired heat pumps are explained.
Mary Anne Sword Sayer; Eric A. Kuehler
2010-01-01
Photosynthate from mature foliage provides the energy source necessary for longleaf pine (Pinus palustris Mill.) root system expansion. Crown scorch caused by repeated prescribed fire could decrease this energy and, in turn, reduce new root production. We conducted a study to assess the root biomass of restored longleaf pine saplings in response to...
Peter J. Daugherty; Jeremy S. Fried
2007-01-01
Landscape-scale fuel treatments for forest fire hazard reduction potentially produce large quantities of material suitable for biomass energy production. The analytic framework FIA BioSum addresses this situation by developing detailed data on forest conditions and production under alternative fuel treatment prescriptions, and computes haul costs to alternative sites...
Kenneth L. Clark; Nicholas Skowronski; Michael Gallagher; Hedi Renninger; Karina Schafer
2012-01-01
We used eddy covariance and meteorological measurements to quantify energy exchange and evapotranspiration (Et) in three representative upland forest stands in the New Jersey Pinelands that were either defoliated by gypsy moth (Lymantria dispar L.) or burned in prescribed fires during the study period. Latent (λE) and sensible heat (H)...
Smedra-Kaźmirska, Anna; Barzdo, Maciej; Kedzierski, Maciej; Szram, Stefan; Berent, Jarosław
2011-01-01
In Poland, according to the Act About Weapons and Ammunition, an air weapon which has kinetic energy of the fired projectiles below 17 J does not require registration and can be bought even on the Internet. Sport and recreation shooting with this weapon basically have to be performed in shooting ranges, but can be also carried on outside of shooting ranges, providing "particular caution" is exercised. In this study, we presented a case of fatal shooting of a 9-year-old boy; the weapon was a Chinese pneumatic device weapon with kinetic energy of the fired projectiles below 17 J. The aim of this study was to compare autopsy findings with penetration depth of missiles fired from this pneumatic weapon in 20% gelatine blocks. During the experiment, we used a Chinese pneumatic weapon with kinetic energy below 17 J, five kinds of lead projectiles with different shape and mass and 20% gelatine blocks at the temperature of 10 degrees C, which were the model of human soft tissues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwager, K.
The Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) is written to comply with Department of Energy (DOE) Integrated Safety Management Policy; Federal Wildland Fire Management Policy and Program Review; and Wildland and Prescribed Fire Management Policy and Implementation Procedures Reference Guide. This current plan incorporates changes resulting from new policies on the national level as well as significant changes to available resources and other emerging issues, and replaces BNL's Wildland FMP dated 2014.
NASA Technical Reports Server (NTRS)
Schutter, K. J.; Duskin, F. E.
1982-01-01
Full-scale burn tests were conducted on thirteen different seat cushion configurations in a cabin fire simulator. The fire source used was a quartz lamp radiant energy panel with a propane pilot flame. During each test, data were recorded for cushion temperatures, radiant heat flux, rate of weight loss of test specimens, and cabin temperatures. When compared to existing passenger aircraft seat cushions, the test specimens incorporating a fire barrier and those fabricated from advance materials, using improved construction methods, exhibited significantly greater fire resistance.
A Brief History of Fire, Heat and Their Manifestations in Remote Sensing
NASA Astrophysics Data System (ADS)
Alavipanah, S. K.; Attarchi, S.
2015-12-01
The discovery of fire was one of the earliest of human discoveries. At the beginning, man sensed heat on his skin and then perceived the concept of fire and temperature. Fire and its manifestation in form of light and heat have contributed in many literary sources and religious books. It has being interpreted in various manners and construed by different explanations. Some of these definitions have resemblances with today's human findings in the argument about heat, temperature, light and their spectra. In this work, we reviewed a broad range of literary, historical, religious and cultural sources to gain deeper insight into the meaning of fire and heat in human's thought, beliefs and myths from the past to today. We found a close linkage between predecessor's perception and impression about heat and what is known today as thermal energy. It should be mentioned that we strictly deny the claim of their awareness of modern concepts such as energy or thermodynamics. However, we interfere that they perceived these conceptions. We cannot clearly explain how our predecessor shaped their impression about fire and heat without any knowledge of the nature of new science such as energy, temperature and thermal remote sensing. Nevertheless, their though compromise with modern science. According to the recent findings, temperature play important role as an efficient indicator of sustainability in landscape. Magnitude and distribution of temperature and its changes over time - which could be traced by thermal remote sensing- are of great importance. A concise literature review relating to fire and heat will broaden our knowledge about temperature and thermal remote sensing.
Navarro, Kathleen M; Cisneros, Ricardo; Noth, Elizabeth M; Balmes, John R; Hammond, S Katharine
2017-06-06
Wildland firefighters suppressing wildland fires or conducting prescribed fires work long shifts during which they are exposed to high levels of wood smoke with no respiratory protection. Polycyclic aromatic hydrocarbons (PAHs) are hazardous air pollutants formed during incomplete combustion. Exposure to PAHs was measured for 21 wildland firefighters suppressing two wildland fires and 4 wildland firefighters conducting prescribed burns in California. Personal air samples were actively collected using XAD4-coated quartz fiber filters and XAD2 sorbent tubes. Samples were analyzed for 17 individual PAHs through extraction with dichloromethane and gas chromatograph-mass spectrometer analysis. Naphthalene, retene, and phenanthrene were consistently the highest measured PAHs. PAH concentrations were higher at wildland fires compared to prescribed fires and were highest for firefighters during job tasks that involve the most direct contact with smoke near an actively burning wildland fire. Although concentrations did not exceed current occupational exposure limits, wildland firefighters are exposed to PAHs not only on the fire line at wildland fires, but also while working prescribed burns and while off-duty. Characterization of occupational exposures from wildland firefighting is important to understand better any potential long-term health effects.
Ectomycorrhizal fungal spore bank recovery after a severe forest fire: some like it hot.
Glassman, Sydney I; Levine, Carrie R; DiRocco, Angela M; Battles, John J; Bruns, Thomas D
2016-05-01
After severe wildfires, pine recovery depends on ectomycorrhizal (ECM) fungal spores surviving and serving as partners for regenerating forest trees. We took advantage of a large, severe natural forest fire that burned our long-term study plots to test the response of ECM fungi to fire. We sampled the ECM spore bank using pine seedling bioassays and high-throughput sequencing before and after the California Rim Fire. We found that ECM spore bank fungi survived the fire and dominated the colonization of in situ and bioassay seedlings, but there were specific fire adapted fungi such as Rhizopogon olivaceotinctus that increased in abundance after the fire. The frequency of ECM fungal species colonizing pre-fire bioassay seedlings, post-fire bioassay seedlings and in situ seedlings were strongly positively correlated. However, fire reduced the ECM spore bank richness by eliminating some of the rare species, and the density of the spore bank was reduced as evidenced by a larger number of soil samples that yielded uncolonized seedlings. Our results show that although there is a reduction in ECM inoculum, the ECM spore bank community largely remains intact, even after a high-intensity fire. We used advanced techniques for data quality control with Illumina and found consistent results among varying methods. Furthermore, simple greenhouse bioassays can be used to determine which fungi will colonize after fires. Similar to plant seed banks, a specific suite of ruderal, spore bank fungi take advantage of open niche space after fires.
Ectomycorrhizal fungal spore bank recovery after a severe forest fire: some like it hot
Glassman, Sydney I; Levine, Carrie R; DiRocco, Angela M; Battles, John J; Bruns, Thomas D
2016-01-01
After severe wildfires, pine recovery depends on ectomycorrhizal (ECM) fungal spores surviving and serving as partners for regenerating forest trees. We took advantage of a large, severe natural forest fire that burned our long-term study plots to test the response of ECM fungi to fire. We sampled the ECM spore bank using pine seedling bioassays and high-throughput sequencing before and after the California Rim Fire. We found that ECM spore bank fungi survived the fire and dominated the colonization of in situ and bioassay seedlings, but there were specific fire adapted fungi such as Rhizopogon olivaceotinctus that increased in abundance after the fire. The frequency of ECM fungal species colonizing pre-fire bioassay seedlings, post-fire bioassay seedlings and in situ seedlings were strongly positively correlated. However, fire reduced the ECM spore bank richness by eliminating some of the rare species, and the density of the spore bank was reduced as evidenced by a larger number of soil samples that yielded uncolonized seedlings. Our results show that although there is a reduction in ECM inoculum, the ECM spore bank community largely remains intact, even after a high-intensity fire. We used advanced techniques for data quality control with Illumina and found consistent results among varying methods. Furthermore, simple greenhouse bioassays can be used to determine which fungi will colonize after fires. Similar to plant seed banks, a specific suite of ruderal, spore bank fungi take advantage of open niche space after fires. PMID:26473720
Chemistry and phase evolution during roasting of toxic thallium-bearing pyrite.
Lopez-Arce, Paula; Garcia-Guinea, Javier; Garrido, Fernando
2017-08-01
In the frame of a research project on microscopic distribution and speciation of geogenic thallium (Tl) from contaminated mine soils, Tl-bearing pyrite ore samples from Riotinto mining district (Huelva, SW Spain) were experimentally fired to simulate a roasting process. Concentration and volatility behavior of Tl and other toxic heavy metals was determined by quantitative ICP-MS, whereas semi-quantitative mineral phase transitions were identified by in situ thermo X-Ray Diffraction (HT-XRD) and Scanning Electron Microscopy with Energy Dispersive Spectroscopy (SEM-EDS) analyses after each firing temperature. Sample with initial highest amount of quartz (higher Si content), lowest quantity of pyrite and traces of jarosite (lower S content) developed hematite and concentrated Tl (from 10 up to 72 mg kg -1 ) after roasting at 900 °C in an oxidizing atmosphere. However, samples with lower or absent quartz content and higher pyrite amount mainly developed magnetite, accumulating Tl between 400 and 500 °C and releasing Tl from 700 up to 900 °C (from 10-29 mg kg -1 down to 4-1 mg kg -1 ). These results show the varied accumulative, or volatile, behaviors of one of the most toxic elements for life and environment, in which oxidation of Tl-bearing Fe sulfides produce Fe oxides wastes with or without Tl. The initial chemistry and mineralogy of pyrite ores should be taken into account in coal-fired power stations, cement or sulfuric acid production industry involving pyrite roasting processes, and steel, brick or paint industries, which use iron ore from roasted pyrite ash, where large amounts of Tl entail significant environmental pollution. Copyright © 2017 Elsevier Ltd. All rights reserved.
Changes in contaminant loading and hydro-chemical storm behavior after the Station Fire
NASA Astrophysics Data System (ADS)
Burke, M. P.; Hogue, T. S.; Barco, J.; Wessel, C. J.
2010-12-01
The 2009 Station Fire, currently noted as the largest fire in Los Angeles County history, consumed over 650 square kilometers of National Forest land in the San Gabriel Mountain Range. These mountains, located on the east side (leeward) of the Los Angeles basin, are known to have some of the highest deposition rates of atmospheric pollutants in the nation. Even pre-fire, urban-fringe basins in this mountain range serve as an upstream source of contaminants to downstream urban streams. Burned watersheds undergo significant physical and chemical changes that dramatically alter hydrologic flowpaths, erosion potential, surface soil chemistry, and pollutant delivery. Much of the degradation in water quality is attributed to the extensive soil erosion during post-fire runoff events which carry large sediment loads, mobilizing and transporting contaminants to and within downstream waters. High resolution storm samples collected from a small front range watershed provide a unique opportunity to investigate the impacts of wildfire contaminant loading in a watershed that is significantly impacted by high atmospheric deposition of urban contaminates. Data includes four events from WY 2009 (pre-fire) and WY 2010 (post-fire), along with inter-storm grab samples from each storm season. Samples were analyzed for basic anions, nutrients, trace metals, and total suspended solids. Following the fire, storms with similar precipitation patterns yielded loads up to three orders of magnitude greater than pre-fire for some toxic metals, including lead and cadmium. Dramatic increases were also observed in trace metal concentrations typically associated with particulates, while weathering solute concentrations decreased. Post fire intra-storm dynamics exhibited a shift back toward pre-fire behavior by the end of the first rainy season for most of the measured constituents. Additionally, some unexpected behaviors were observed; specifically mercury loads continued to increase throughout the first post-fire rainy season regardless of storm size.
Post-fire analysis of construction materials
NASA Astrophysics Data System (ADS)
Schroeder, Robert Allen
The objective of this thesis is to determine and document the extent to which the fire damage in wood, concrete, and gypsum wallboard can be used to determine the time and heat flux exposure of the incipient stages of an uncontrolled fire event. A literature review outlines the state-of-the-art in three distinct areas: (1) Fire investigation; (2) The physical properties of wood, concrete, and gypsum wallboard, and (3) The fire response characteristics of those materials and their use in fire investigations. The results from quantitative experimental fire exposures of the subject materials are presented. The experiments were conducted under controlled conditions with the intent to develop standards for macroscopic and microscopic states of the materials for a given heat flux exposure and temperature. Standards and procedures are introduced for field sample collection, laboratory testing of the field samples, and interpretation of results. There are three major conclusions to be derived from this dissertation. The first two are that (1) wood and (2) concrete should not be viewed as reliable sources of information for a fire investigator to use for an analysis of how an actual fire ignited or spread. On the other hand the third major conclusion is that (3) gypsum wallboard can be considered a reliable source of information of fire behavior. The basis of each these conclusions is described in each of the chapters associated with each of the materials. One of the most important findings in this research is the use of X-ray diffraction to determine the maximum temperature reached by a sample of gypsum wallboard. Then by using the plots of isotherm progression it is possible to estimate the approximate length of exposure to a given heat flux. The use of gypsum-based post evidence is much more accurate than any available for wood or for concrete.
Recent Progress and Emerging Issues in Measuring and Modeling Biomass Burning Emissions
NASA Astrophysics Data System (ADS)
Yokelson, R. J.; Stockwell, C.; Veres, P. R.; Hatch, L. E.; Barsanti, K. C.; Simpson, I. J.; Blake, D. R.; Alvarado, M.; Kreidenweis, S. M.; Robinson, A. L.; Akagi, S. K.; McMeeking, G. R.; Stone, E.; Gilman, J.; Warneke, C.; Sedlacek, A. J.; Kleinman, L. I.
2013-12-01
Nine recent multi-PI campaigns (6 airborne, 3 laboratory) have quantified biomass burning emissions and the subsequent smoke evolution in unprecedented detail. Among these projects were the Fourth Fire Lab at Missoula Experiment (FLAME-4) and the DOE airborne campaign BBOP (Biomass Burning Observation Project). Between 2009 and 2013 a large selection of fuels and ecosystems were probed including: (1) 21 US prescribed fires in pine forests, chaparral, and shrublands; (2) numerous wildfires in the Pacific Northwest of the US; (3) 77 lab fires burning fuels collected from the sites of the prescribed fires; and (4) 158 lab fires burning authentic fuels in traditional cooking fires and advanced stoves; peat from Indonesia, Canada, and North Carolina; savanna grasses from Africa; temperate grasses from the US; crop waste from the US; rice straw from Taiwan, China, Malaysia, and California; temperate and boreal forest fuels collected in Montana and Alaska; chaparral fuels from California; trash; and tires. Instrumentation for gases included: FTIR, PTR-TOF-MS, 2D-GC and whole air sampling. Particle measurements included filter sampling (with IC, elemental carbon (EC), organic carbon (OC), and GC-MS) and numerous real-time measurements such as: HR-AMS (high-resolution aerosol MS), SP-AMS (soot particle AMS), SP2 (single particle soot photometer), SP-MS (single particle MS), ice nuclei, CCN (cloud condensation nuclei), water soluble OC, size distribution, and optical properties in the UV-VIS. New data include: emission factors for over 400 gases, black carbon (BC), brown carbon (BrC), organic aerosol (OA), ions, metals, EC, and OC; and details of particle morphology, mixing state, optical properties, size distributions, and cloud nucleating activity. Large concentrations (several ppm) of monoterpenes were present in fresh smoke. About 30-70% of the initially emitted gas-phase non-methane organic compounds were semivolatile and could not be identified with current technology. The detection rate for the sampled US prescribed fires was zero by burned area and <30% by active fire detection. Smoke evolution was measured for numerous gas-phase precursors and products, ozone, OA, ions, and BC and BrC mixing state. BC particles were coated within one hour and the smoke evolution was, in general, strongly impacted by the unidentified low volatility gases. An informative synthesis of lab and field fire data with fuels from the same sites was carried out. A preliminary comparison of wildfire and prescribed fire emissions will be presented. Novel schemes are under development to summarize the new emissions data for models, with limited mechanisms and parameterize fast, sub-grid processes. Key current issues to be discussed include: packaging/parameterizing the recent explosion of emissions/evolution data for use in model mechanisms; addressing fires not detected from space; addressing the large amount of unidentified semi-volatile gases emitted by all fires; and developing appropriate airborne and ground-based sampling scales/strategies for local-global models. We briefly summarize a recently funded project that will sample emissions and quantify biomass consumption by peat fires in Indonesia and a pending proposal for comprehensive sampling of cooking fires, brick kilns, garbage burning, diesel super-emitters, etc. in South Asia.
Analysis of NASA JP-4 fire tests data and development of a simple fire model
NASA Technical Reports Server (NTRS)
Raj, P.
1980-01-01
The temperature, velocity and species concentration data obtained during the NASA fire tests (3m, 7.5m and 15m diameter JP-4 fires) were analyzed. Utilizing the data analysis, a sample theoretical model was formulated to predict the temperature and velocity profiles in JP-4 fires. The theoretical model, which does not take into account the detailed chemistry of combustion, is capable of predicting the extent of necking of the fire near its base.
Reconstructing fire history of lodgepole pine on Chagoopa Plateau, Sequoia National Park, California
Anthony C. Caprio
2008-01-01
Information on fireâs role in pre-twentieth-century lodgepole pine forests of the southern Sierra Nevada is limited. It has generally been assumed that fire plays only a minor role in lodgepoleâs dynamics unlike in other portions of its range. This assertion was examined by sampling fire-scarred trees and reconstructing fire history in monospecific stands of lodgepole...
Kristen L. Shive; Amanda M. Kuenzi; Carolyn H. Sieg; Peter Z. Fule
2013-01-01
We used a multi-year data set from the 2002 Rodeo-Chediski Fire to detect post-fire trends in plant community response in burned ponderosa pine forests. Within the burn perimeter, we examined the effects of pre-fire fuels treatments on post-fire vegetation by comparing paired treated and untreated sites on the Apache-Sitgreaves National Forest.We sampled these paired...
NASA Astrophysics Data System (ADS)
Kus, Jolanta; Meyer, Uwe; Ma, Jianwei; Chen-Brauchler, Dai
2010-05-01
At the coalfield of Wuda (Inner Mongolia, PR China) extensive underground coal fires cause widespread thermal and oxidative effects in coal seams. Within phase B of the Coal Fire Research Project of the Sino-German Initiative, methods for innovative fire-extinguishing technologies were investigated in multifaceted research approaches. Extensive investigations of oxidative and thermally affected coal seams in coal fire zone 18 were conducted in 2008 prior to application of new fire-extinguishing methods. We present results from the outcrop of coal seam No. 4 in the fire zone 18. The coal of seam No. 4 is of Early Permian age and belongs stratigraphically to the Shanxi Formation. The unaffected coal displays a high volatile bituminous A rank with a background value of random vitrinite reflectance ranging from 0.90 to 0.96 % Rr. Coal channel samples were coallected at actively extracted coal faces along multiple profiles with surface temperatures ranging from about 50° to 600°C. Microscopic examinations revealed a variety of products of coal exposure to the fire. Within coal samples, a marked rise in vitrinite reflectance from background values to 5.55% Rr (6.00 % Rmax) is encountered. In addition, a number of coal samples showed suppressed vitrinite reflectances ranging between 0.82 to 0.88% Rr. Further, seemingly heat unaffected coal samples display intensive development of oxidations rims at coal grain edges and cracks as well as shrinkage cracks and formation of iron oxides/hydroxides. Instead, thermally affected coal samples with higher coalification grade are further characterised by development of macropores (devolatilisation pores) in vitrinitic streaks, transformation of liptinite to meta-liptinite and micrinite as well as by natural coke particles of mostly porous nature and fine to coarse grained anisotropic mosaic. Coal petrographic investigations confirmed a hypothesis that both, oxidations as well as low temperature carbonisation govern the thermal regime in the coal fire zone 18. The occurrence of various thermal alteration products indicates temperatures in the range of 500-700°C.
NASA Astrophysics Data System (ADS)
Jiménez-González, Marco A.; Jordán, Antonio; Zavala, Lorena M.; Mataix-Solera, Jorge; Bárcenas-Moreno, Gema; Jiménez-Morillo, Nicasio T.; Bellinfante, Nicolás
2014-05-01
1. INTRODUCTION Wildfires may induce important chemical and physical changes in soils, including changes in the soil composition, mineralogical changes, soil water repellency, aggregate stability or textural changes (Bodí et al., 2013; Granged et al., 2011a, 2011b, 2011c; Jordán et al., 2011, 2013; Mataix-Solera et al., 2011). As these changes usually occur after threshold temperature peaks, the assessment of these helps to explain many of the processes occurring during burning and in the postfire (Pereira et al., 2012, 2013; Shakesby, 2011). In July 2011, a wildfire burnt a pine forested area (50 ha) in Gorga (Alicante, SW Spain), approximately at 38° 44.3' N and 0° 20.7' W. Main soil type is Lithic Xerorthent developed from limestone. The study of mineralogical changes in soil after a wildfire should help to assess fire temperature peaks reached during burning. In order to study the impact of fire temperature on mineralogical changes and determine temperature peaks during burning, burnt soil plots under shrubland were randomly collected (0-5 cm deep). Control samples from adjacent unburnt areas were also collected for control. 2. METHODS Soil samples were ground using an agate mortar and then sieved (< 0.002mm) and analyzed by X-ray diffraction (XRD). XRD was conducted on a Bruker (model D8 advance A25) powder θ:θ diffractometer, which uses a Cu anticathode (40KV, 30mA), Ni filter in the diffracted bean and lineal detector. Powder samples were scanned from 3 to 70° 2θ, using a step size of 0.015° 2θ and a scan speed of 0.15° 2θ s-1. Mineralogical phase identification and quantification of minerals was carried out with XPowder. In order to study other possible reaction in burnt soil, unburnt soil samples were exposed to temperatures of 300, 500 and 700 °C in a Mufla furnace during 20 minutes. Unburnt control and treated samples were analyzed by differential thermal analysis (DTA) and thermogravimetric analysis (TG). 3. RESULTS Diffractograms show that the blixita peak, found in the control sample, disappears in the diffractograms of burnt samples. Other significant peaks (calcite, quartz and microcline, for example) do not show significant changes between control and burnt samples. After semiquantitative analysis, the proportion of calcite increased in burnt soil samples (76.3%, on average) respect to control unburnt soil samples (62.3%). This increase may be explained by calcium carbonate released by ash after combustion of organic matter. Consequently, quartz proportion decreased in burnt samples (10.7%, on average) respect to control samples (26.1%). After DTA analysis, a valley occurs between 400 and 700 °C in the control sample which is not present in 500 and 700 oC heated samples. This loss of energy is attributed to combustion of organic matter approximately between 400 and 500 °C, as well as thermal changes in iron oxides (which occurs approximately between 300 and 500 °C) and loss of structural water (>420 °C). In samples heated at 500 and 700 °C, these changes are not appreciated as they occurred during calcination. In the 300 °C heated sample, some of these changes partially occurred. Peaks observed approximately at 100 °C correspond to release of absorbed water. Peaks at 900 °C are a consequence of destruction of calcite. Finally a peak was observed at 680 °C in the control sample may be explained as a consequence of the destruction of blixite (Pb8(OH)2Cl4), which was present in control samples (1.1%) but not in burnt samples. This peak is probably masked in heated samples. REFERENCES Bodí, M.B., Muñoz-Santa, I., Armero, C., Doerr, S.H., Mataix-Solera, J., Cerdà, A. 2013. Spatial and temporal variations of water repellency and probability of its occurrence in calcareous Mediterranean rangeland soils affected by fires. Catena, 108, 14-25. Granged, A.J.P., Jordán, A., Zavala, L.M., Muñoz-Rojas, M., Mataix-Solera, J. 2011a. Short-term effects of experimental fire for a soil under eucalyptus forest (SE Australia). Geoderma, 167-168, 125-134. Granged, A.J.P., Zavala, L.M., Jordán, A., Bárcenas-Moreno, B. 2011b. Post-fire evolution of soil properties and vegetation cover in a Mediterranean heathland after experimental burning: A 3-year study. Geoderma, 164, 85-94. Granged, A.J.P., Jordán, A., Zavala, L.M., Bárcenas-Moreno, B. 2011c. Fire-induced changes in soil water repellency increased fingered flow and runoff rates following the 2004 Huelva wildfire. Hydrological Processes, 25, 1614-1629. Jordán, A., Zavala, L.M., Mataix-Solera, J., Nava, A.L., Alanís, N. 2011. Effect of fire severity on water repellency and aggregate stability on Mexican volcanic soils. Catena, 84, 136-147. Jordán A., Zavala, L.M., Mataix-Solera, J., Doerr, S.H. 2013. Soil water repellency: Origin, assessment and geomorphological consequences. Catena, 108, 1-5. Mataix-Solera, J., Cerdà, A., Arcenegui, V., Jordán, A., Zavala, L.M. 2011. Fire effects on soil aggregation: A review. Earth-Science Reviews, 109, 44-60. Pereira, P., Mierauskas, P., Úbeda, X., Mataix-Solera, J., Cerdà, A. 2012. Fire in Protected Areas - the Effect of Protection and Importance of Fire Management. Environmental Research, Engineering and Management, 59, 52-62. Pereira, P., Cerdà, A., Úbeda, X., Mataix-Solera, J., Martin, D., Jordán, A., Burguet, M. 2013. Spatial models for monitoring the spatio-temporal evolution of ashes after fire - a case study of a burnt grassland in Lithuania. Solid Earth 4, 153-165. Shakesby, R.A. 2011. Post-wildfire soil erosion in the Mediterranean: review and future research directions. Earth-Science Reviews, 71-100.
Combustion Processes in the Aerospace Environment
NASA Technical Reports Server (NTRS)
Huggett, Clayton
1969-01-01
The aerospace environment introduces new and enhanced fire hazards because the special atmosphere employed may increase the frequency and intensity of fires, because the confinement associated with aerospace systems adversely affects the dynamics of fire development and control, and because the hostile external environments limit fire control and rescue operations. Oxygen enriched atmospheres contribute to the fire hazard in aerospace systems by extending the list of combustible fuels, increasing the probability of ignition, and increasing the rates of fire spread and energy release. A system for classifying atmospheres according to the degree of fire hazard, based on the heat capacity of the atmosphere per mole of oxygen, is suggested. A brief exploration of the dynamics of chamber fires shows that such fires will exhibit an exponential growth rate and may grow to dangerous size in a very short time. Relatively small quantities of fuel and oxygen can produce a catastrophic fire in a closed chamber.
Carbon and Aerosol Emissions from Biomass Fires in Mexico
NASA Astrophysics Data System (ADS)
Hao, W. M.; Flores Garnica, G.; Baker, S. P.; Urbanski, S. P.
2009-12-01
Biomass burning is an important source of many atmospheric greenhouse gases and photochemically reactive trace gases. There are limited data available on the spatial and temporal extent of biomass fires and associated trace gas and aerosol emissions in Mexico. Biomass burning is a unique source of these gases and aerosols, in comparison to industrial and biogenic sources, because the locations of fires vary considerably both daily and seasonally and depend on human activities and meteorological conditions. In Mexico, the fire season starts in January and about two-thirds of the fires occur in April and May. The amount of trace gases and aerosols emitted by fires spatially and temporally is a major uncertainty in quantifying the impact of fire emissions on regional atmospheric chemical composition. To quantify emissions, it is necessary to know the type of vegetation, the burned area, the amount of biomass burned, and the emission factor of each compound for each ecosystem. In this study biomass burning experiments were conducted in Mexico to measure trace gas emissions from 24 experimental fires and wildfires in semiarid, temperate, and tropical ecosystems from 2005 to 2007. A range of representative vegetation types were selected for ground-based experimental burns to characterize fire emissions from representative Mexico fuels. A third of the country was surveyed each year, beginning in the north. The fire experiments in the first year were conducted in Chihuahua, Nuevo Leon, and Tamaulipas states in pine forest, oak forest, grass, and chaparral. The second-year fire experiments were conducted on pine forest, oak forest, shrub, agricultural, grass, and herbaceous fuels in Jalisco, Puebla, and Oaxaca states in central Mexico. The third-year experiments were conducted in pine-oak forests of Chiapas, coastal grass, and low subtropical forest on the Yucatan peninsula. FASS (Fire Atmosphere Sampling System) towers were deployed for the experimental fires. Each FASS system contains 4 electro-polished stainless steel canisters to sample trace gas emissions, with a corresponding set of Teflon filters in the sampling ports to collect PM2.5 particulates. In addition, biomass burning was sampled by aircraft with canisters and real-time instruments as part of the MILAGRO field campaign. We present the emission factors of CO2, CO, CH4, C2-C4 compounds, and PM2.5 for prescribed fires of the major vegetation types in Mexico, as well as for regional wildfires in southern and central Mexico. We will also present a high-resolution vegetation map in Mexico based on the Landsat satellites and the fuel consumption models for various components and sizes of fuels.
Meng, Juncai; Lai, Ming-Tain; Munshi, Vandna; Grobler, Jay; McCauley, John; Zuck, Paul; Johnson, Eric N; Uebele, Victor N; Hermes, Jeffrey D; Adam, Gregory C
2015-06-01
HIV-1 protease (PR) represents one of the primary targets for developing antiviral agents for the treatment of HIV-infected patients. To identify novel PR inhibitors, a label-free, high-throughput mass spectrometry (HTMS) assay was developed using the RapidFire platform and applied as an orthogonal assay to confirm hits identified in a fluorescence resonance energy transfer (FRET)-based primary screen of > 1 million compounds. For substrate selection, a panel of peptide substrates derived from natural processing sites for PR was evaluated on the RapidFire platform. As a result, KVSLNFPIL, a new substrate measured to have a ~ 20- and 60-fold improvement in k cat/K m over the frequently used sequences SQNYPIVQ and SQNYPIV, respectively, was identified for the HTMS screen. About 17% of hits from the FRET-based primary screen were confirmed in the HTMS confirmatory assay including all 304 known PR inhibitors in the set, demonstrating that the HTMS assay is effective at triaging false-positives while capturing true hits. Hence, with a sampling rate of ~7 s per well, the RapidFire HTMS assay enables the high-throughput evaluation of peptide substrates and functions as an efficient tool for hits triage in the discovery of novel PR inhibitors. © 2015 Society for Laboratory Automation and Screening.
NASA Astrophysics Data System (ADS)
Mohammed, I.; Abu Talib, A. R.; Sultan, M. T. H.; Saadon, S.
2017-12-01
Aerospace and other industries use fibre metal laminate composites extensively due to their high specific strength, stiffness and fire resistance, in addition to their capability to be tailored into different forms for specific purposes. The behaviours of such composites under impact loading is another factor to be considered due to the impacts that occur in take-off, landing, during maintenance and operations. The aim of the study is to determine the specific perforation energy and impact strength of the fibre metal laminates of different layering pattern of carbon fibre reinforced aluminium alloy and hybrid laminate composites of carbon fibre and natural fibres (kenaf and flax). The composites are fabricated using the hand lay-up method in a mould with high bonding polymer matrix and compressed by a compression machine, cured at room temperature for one day and post cure in an oven for three hours. The impact tests are conducted using a gun tunnel system with a flat cylindrical bullet fired using a helium gas at a distance of 14 inches to the target. Impact and residual velocity of the projectile are recorded by high speed video camera. Specific perforation energy of carbon fibre reinforced aluminium alloy (CF+AA) for both before and after fire test are higher than the specific perforation energy of the other composites considered before and after fire test respectively. CF +AA before fire test is 55.18% greater than after. The same thing applies to impact strength of the composites where CF +AA before the fire test has the highest percentage of 11.7%, 50.0% and 32.98% as respectively compared to carbon fibre reinforced aluminium alloy (CARALL), carbon fibre reinforced flax aluminium alloy (CAFRALL) and carbon fibre reinforced kenaf aluminium alloy (CAKRALL), and likewise for the composites after fire test. The considered composites in this test can be used in the designated fire zone of an aircraft engine to protect external debris from penetrating the engine shield due to higher values of impact strength and specific perforation energy as highlighted by the test results.
Jha, Vinay Kumar; Kameshima, Yoshikazu; Nakajima, Akira; Okada, Kiyoshi; MacKenzie, Kenneth J D
2005-08-31
A series of nCaO.Al2O3.2SiO2 samples (n=1-4) were prepared by solid-state reaction of mechanochemically treated mixtures of kaolinite and calcite fired at 600-1000 degrees C for 24 h. All the samples were X-ray amorphous after firing at 600-800 degrees C but had crystallized by 900 degrees C. The main crystalline phases were anorthite (n=1), gehlenite (n=2 and 3) and larnite (n=4). The uptake of Ni2+ by nCaO.Al2O3.2SiO2 samples fired at 800 and 900 degrees C was investigated at room temperature using solutions with initial Ni2+ concentrations of 0.1-50 mmol/l. Amorphous samples (fired at 800 degrees C) showed a higher Ni2+ uptake capacity than crystalline samples (fired at 900 degrees C). Ni2+ uptake was found to increase with increasing of CaO content. Amorphous 4CaO.Al2O3.2SiO2 showed the highest Ni2+ uptake capacity (about 9 mmol/g). The Ni2+ uptake abilities of the present samples are higher than those of other materials reported in the literature. Since the sorbed Ni2+/released Ca2+ ratios of these samples are close to unity, ion replacement of Ni2+ for Ca2+ is thought to be the principal mechanism of Ni2+ uptake by the present samples.
Pigments which reflect infrared radiation from fire
Berdahl, P.H.
1998-09-22
Conventional paints transmit or absorb most of the intense infrared (IR) radiation emitted by fire, causing them to contribute to the spread of fire. The present invention comprises a fire retardant paint additive that reflects the thermal IR radiation emitted by fire in the 1 to 20 micrometer ({micro}m) wavelength range. The important spectral ranges for fire control are typically about 1 to about 8 {micro}m or, for cool smoky fires, about 2 {micro}m to about 16 {micro}m. The improved inventive coatings reflect adverse electromagnetic energy and slow the spread of fire. Specific IR reflective pigments include titanium dioxide (rutile) and red iron oxide pigments with diameters of about 1 {micro}m to about 2 {micro}m and thin leafing aluminum flake pigments. 4 figs.
Francos, Marcos; Pereira, Paulo; Alcañiz, Meritxell; Úbeda, Xavier
2018-08-15
Post-fire management practices after wildfires have an important impact on soil properties. Nevertheless, little research has been carried out. The aim of this study is to examine the impact of different post-wildfire forest management practices in a 10-month period immediately after a severe wildfire on soil properties. Two months after a wildfire, three experimental areas were designed, each one with different post-fire management: Cut and Remove (CR) where burned trunks were cut after fire and removed manually from the area; No Treatment (NT) where no intervention was carried out; and, Cut and Leave (CL) where burned trunks were cut and left randomly on topsoil. In each treatment, we collected nine samples (0-5cm deep). In total, we sampled 27 samples in each sampling date, two and ten months after the wildfire. The properties analyzed were aggregate stability (AS), total nitrogen (TN), soil organic matter (SOM), inorganic carbon (IC), C/N ratio, pH, electrical conductivity (EC), extractable calcium (Ca), magnesium (Mg), sodium (Na) and potassium (K). Soil C/N ratio was significantly higher in CR and CL treatments 10months after fire comparing to 2months after. On the other hand, pH, extractable Ca, Mg and K were significantly higher in all the treatments 2months after fire than 10months after. Aggregate stability, TN and SOM were significantly higher in CR comparing to CL, 10months after the fire. IC was significantly higher in CL than in NT treatment, also, 10months after the fire. Electrical conductivity was significantly higher in CR and CL treatments 2months after fire comparing to 10months after. According to the results, CR and CL post-fire management did not differ importantly from the NT scenario, showing that manual wood management does not have detrimental impacts on soil properties compared to mechanical operations. Copyright © 2018 Elsevier B.V. All rights reserved.
Gomes, J F P; Radovanovic, M
2008-05-01
Fires of large dimension destroy forests, harvests and housing objects. Apart from that combustion products and burned surfaces become large ecological problems. Very often fires emerge simultaneously on different locations of a region so a question could be asked if they always have been a consequence of negligence, pyromania, high temperatures or maybe there has been some other cause. This paper is an attempt of establishing the possible connection between forest fires that numerous satellites registered and activities happening on the Sun immediately before fires ignite. Fires emerged on relatively large areas from Portugal and Spain on August 2005, as well as on other regions of Europe. The cases that have been analyzed show that, in every concrete situation, an emission of strong electromagnetic and thermal corpuscular energy from highly energetic regions that were in geo-effective position had preceded the fires. Such emissions have, usually, very high energy and high speeds of particles and come from coronary holes that also have been either in the very structure or in the immediate closeness of the geo-effective position. It should also be noted that the solar wind directed towards the Earth becomes weaker with deeper penetration towards the topographic surface. However, the results presented in this paper suggest that, there is a strong causality relationship between solar activity and the ignition of these forest fires taking place in South-western Europe.
NASA Astrophysics Data System (ADS)
Yin, Libao; Liao, Yanfen; Liu, Guicai; Liu, Zhichao; Yu, Zhaosheng; Guo, Shaode; Ma, Xiaoqian
2017-05-01
Energy consumption and pollutant emission of natural gas combined cycle power-generation (NGCC), liquefied natural gas combined cycle power-generation (LNGCC), natural gas combined heat and power generation (CHP) and ultra-supercritical power generation with ultra-low gas emission (USC) were analyzed using life cycle assessment method, pointing out the development opportunity and superiority of gas power generation in the period of coal-fired unit ultra-low emission transformation. The results show that CO2 emission followed the order: USC>LNGCC>NGCC>CHP the resource depletion coefficient of coal-fired power generation was lower than that of gas power generation, and the coal-fired power generation should be the main part of power generation in China; based on sensitivity analysis, improving the generating efficiency or shortening the transportation distance could effectively improve energy saving and emission reduction, especially for the coal-fired units, and improving the generating efficiency had a great significance for achieving the ultra-low gas emission.
NASA Astrophysics Data System (ADS)
Nkansah, Kofi
During the 2015 legislative session, West Virginia lawmakers passed a bill to repeal the Renewable and Alternative Energy Portfolio Standards Act of 2009 (ARPS). Legislators stated concerns about ARPS's impacts on coal industry related jobs in the state as the major factor driving this repeal. However, no comprehensive study on public acceptance, opinions, or willingness to pay (WTP) for renewable/and or alternative sources of electricity within West Virginia was used to inform this repeal decision. As the state of West Virginia struggles to find the right path to expand its renewable energy portfolio, public acceptance of renewable electricity is crucial to establishing a viable market for these forms of energy and also ensure the long-term sustainability of any RPS policy that may be enacted in the future. This study sought to assess consumers' preferences, attitudes and WTP for renewable and alternative electricity in West Virginia. The monetary values that consumers placed on proximity as an attribute of a renewable and alternative electricity generation source were also estimated. Two counties in West Virginia were selected as study areas based on the types of electricity generation facility that already exist in each county -one county with coal-fired power plants (Monongalia County) and another with both a coal-fired power plant and a wind farm (Grant County). A forced choice experiment survey was used with attributes that varied in source of energy (wind versus natural gas), proximity of the generation source relative to the respondent's residence (near, moderate or far) and an additional premium per month on the electric bill (varying from 1 to 15). Respondents were asked to choose between generating 10% of the electricity supplied to them from wind or natural gas. Random samples of 1500 residents from each county were sent surveys and response rates were 27.0% (Monongalia) and 35.3% (Grant). A Mixed logit econometric models were used to analyze consumer choices with utility models. WTP for energy source and proximity attribute levels were computed using parameter estimates from these utility models. Statistically different models were developed for each county. Results from the study showed that respondents in both counties had preferences for electricity generated from wind compared to natural gas. A majority of the sampled populations chose the wind option, 62.0% in Monongalia County and 60.0% in Grant County. The sampled populations in Monongalia and Grant Counties were willing to pay a weighted mean of 21.59 and 9.87 per month, respectively, for 10% of their electricity to be generated from wind over natural gas. Despite this large difference, county level means were not statistically different. On aggregate, a positive social benefit per year would be derived from generating 10% of electricity supplied to consumers in Monongalia County (2.5 million) and Grant County (186 thousand) from wind relative to natural gas. Similarly, the most social benefit would be derived from siting wind turbines at "far" locations from residents in both counties. Both county level sampled populations were willing to pay a higher premium to site wind turbines or a natural gas-fired power plant at the farthest location relative to the baseline location (near a respondent's current residence). Grant County respondents were willing to pay a slightly higher positive premium (mean of 11.71 per month) to site wind turbines at the farthest location than respondents in Monongalia County (mean of 10.14 per month). The mean WTP to site a natural gas-fired power plant at the farthest location in Monongalia County (13.06) and Grant County (13.47) were not statistically different from each other. Results from this study suggest that the decision for an outright repeal of the ARPS bill was flawed. Based on Monongalia and Grant County populations, there are social benefits derived from generating 10% of the electricity supplied to consumers in West Virginia from renewable and alternative energy sources, and wind is preferred to natural gas. This repeal implies there are few, if any, benefits. Given this repeal, I suggest that a voluntary green pricing program with a focus on wind energy serve as an alternative renewable energy policy in West Virginia. Under such a policy, consumers who are concerned about the environment and are willing to pay a positive premium for renewable electricity would be able to opt into the program. Premiums paid by participants of such a program can be used to increase the renewable energy share in West Virginia's energy portfolio.
How to model supernovae in simulations of star and galaxy formation
NASA Astrophysics Data System (ADS)
Hopkins, Philip F.; Wetzel, Andrew; Kereš, Dušan; Faucher-Giguère, Claude-André; Quataert, Eliot; Boylan-Kolchin, Michael; Murray, Norman; Hayward, Christopher C.; El-Badry, Kareem
2018-06-01
We study the implementation of mechanical feedback from supernovae (SNe) and stellar mass loss in galaxy simulations, within the Feedback In Realistic Environments (FIRE) project. We present the FIRE-2 algorithm for coupling mechanical feedback, which can be applied to any hydrodynamics method (e.g. fixed-grid, moving-mesh, and mesh-less methods), and black hole as well as stellar feedback. This algorithm ensures manifest conservation of mass, energy, and momentum, and avoids imprinting `preferred directions' on the ejecta. We show that it is critical to incorporate both momentum and thermal energy of mechanical ejecta in a self-consistent manner, accounting for SNe cooling radii when they are not resolved. Using idealized simulations of single SN explosions, we show that the FIRE-2 algorithm, independent of resolution, reproduces converged solutions in both energy and momentum. In contrast, common `fully thermal' (energy-dump) or `fully kinetic' (particle-kicking) schemes in the literature depend strongly on resolution: when applied at mass resolution ≳100 M⊙, they diverge by orders of magnitude from the converged solution. In galaxy-formation simulations, this divergence leads to orders-of-magnitude differences in galaxy properties, unless those models are adjusted in a resolution-dependent way. We show that all models that individually time-resolve SNe converge to the FIRE-2 solution at sufficiently high resolution (<100 M⊙). However, in both idealized single-SN simulations and cosmological galaxy-formation simulations, the FIRE-2 algorithm converges much faster than other sub-grid models without re-tuning parameters.
Characteristics of smoke emissions from biomass fires of the Amazon region - BASE-A experiment
NASA Technical Reports Server (NTRS)
Ward, Darold E.; Setzer, Alberto W.; Kaufman, Yoram J.; Rasmussen, Rei A.
1991-01-01
The Biomass Burning Airborne and Spaceborne Experiment-Amazonia was designed for study of both aerosol and gaseous emissions from fires using an airborne sampling platform. The emission factors for combustion products from four fires suggest that the proportion of carbon released in the form of CO2 is higher than for fires of logging which has been burned in the western U.S. Combustion efficiency was of the order of 97 percent for the Amazonian test fire and 86-94 percent for deforestation fires. The inorganic content of particles from tropical fires are noted to be different from those of fires in the U.S.
NASA Technical Reports Server (NTRS)
Schroeder, Wilfrid; Ellicott, Evan; Ichoku, Charles; Ellison, Luke; Dickinson, Matthew B.; Ottmar, Roger D.; Clements, Craig; Hall, Dianne; Ambrosia, Vincent; Kremens, Robert
2013-01-01
Ground, airborne and spaceborne data were collected for a 450 ha prescribed fire implemented on 18 October 2011 at the Henry W. Coe State Park in California. The integration of various data elements allowed near coincident active fire retrievals to be estimated. The Autonomous Modular Sensor-Wildfire (AMS) airborne multispectral imaging system was used as a bridge between ground and spaceborne data sets providing high quality reference information to support satellite fire retrieval error analyses and fire emissions estimates. We found excellent agreement between peak fire radiant heat flux data (less than 1% error) derived from near-coincident ground radiometers and AMS. Both MODIS and GOES imager active fire products were negatively influenced by the presence of thick smoke, which was misclassified as cloud by their algorithms, leading to the omission of fire pixels beneath the smoke, and resulting in the underestimation of their retrieved fire radiative power (FRP) values for the burn plot, compared to the reference airborne data. Agreement between airborne and spaceborne FRP data improved significantly after correction for omission errors and atmospheric attenuation, resulting in as low as 5 difference between AquaMODIS and AMS. Use of in situ fuel and fire energy estimates in combination with a collection of AMS, MODIS, and GOES FRP retrievals provided a fuel consumption factor of 0.261 kg per MJ, total energy release of 14.5 x 10(exp 6) MJ, and total fuel consumption of 3.8 x 10(exp 6) kg. Fire emissions were calculated using two separate techniques, resulting in as low as 15 difference for various species
Comparative Soot Diagnostics: 1 Year Report
NASA Technical Reports Server (NTRS)
Urban, David L.; Griffin, DeVon W.; Gard, Melissa Y.
1998-01-01
The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. Bright sooty fires are desirable for efficient energy extraction in furnaces and power equipment. In contrast, soot-enhanced radiation is undesirable in many propulsion systems (e.g. jet engines). The non-buoyant structure of most flames of practical interest (turbulent) makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In addition, recent tests conducted on MIR showed that a candle in a truly quiescent spacecraft environment can burn for tens of minutes. Consequently, this test and many earlier tests have demonstrated that fires in spacecraft can be considered a credible risk. In anticipation of this risk, NASA has included fire detectors on Skylab, smoke detectors on the Space Shuttle (STS), and smoke detectors in the design for the International Space Station (ISS). In the CSD experiment, these smoke detectors were tested using, quasi-steady, low-gravity, particulate generating materials. Samples of the particulate were also obtained from these low-gravity sources. This experiment provides the first such measurements aimed toward understanding of soot processes here on earth and for the testing and design of advanced spacecraft smoke detection systems. This paper describes the operation and preliminary results of the CSD experiment which was was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The objectives of CSD are to examine the particulate emission from a variety of pyrolyzing and combusting sources and to quantify the performance of several particulate-sensing diagnostic techniques. This paper presents the results of the microgravity portion of the CSD experiment. The results include the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes. Complete assessment of the microgravity data and its combination with the normal-gravity data are still in process.
Forest Service Turns to NREL for Help Fighting Fires More Sustainably |
reduce energy and water use as well as waste generation at fire camps and supporting operations , burn less fuel, generate less waste, and recycle more. While NREL is often called upon to identify how fundamentally it would be nice to see some savings realized on the energy, water, or waste side, and to add some
Assessing the Greenhouse Gas Emissions from Natural Gas Fired Power Plants
NASA Astrophysics Data System (ADS)
Hajny, K. D.; Shepson, P. B.; Rudek, J.; Stirm, B. H.; Kaeser, R.; Stuff, A. A.
2017-12-01
Natural gas is often discussed as a "bridge fuel" to transition to renewable energy as it only produces 51% the amount of CO2 per unit energy as coal. This, coupled with rapid increases in production fueled by technological advances, has led to a near tripling of natural gas used for electricity generation since 2005. One concern with this idea of a "bridge fuel" is that methane, the primary component of natural gas, is itself a potent greenhouse gas with 28 and 84 times the global warming potential of CO2 based on mass over a 100 and 20 year period, respectively. Studies have estimated that leaks from the point of extraction to end use of 3.2% would offset the climate benefits of natural gas. Previous work from our group saw that 3 combined cycle power plants emitted unburned CH4 from the stacks and leaked additional CH4 from equipment on site, but total loss rates were still less than 2.2%. Using Purdue's Airborne Laboratory for Atmospheric Research (ALAR) we completed additional aircraft based mass balance experiments combined with passes directly over power plant stacks to expand on the previous study. In this work, we have measured at 12 additional natural gas fired power plants including a mix of operation types (baseload, peaking, intermediate) and firing methods (combined cycle, simple thermal, combustion turbine). We have also returned to the 3 plants previously sampled to reinvestigate emissions for each of those, to assess reproducibility of the results. Here we report the comparison of reported continuous emissions monitoring systems (CEMS) data for CO2 to our emission rates calculated from mass balance experiments, as well as a comparison of calculated CH4 emission rates to estimated emission rates based on the EPA emission factor of 1 g CH4/mmbtu natural gas and CEMS reported heat input. We will also discuss emissions from a coal-fired plant which has been sampled by the group in the past and has since converted to natural gas. Lastly, we discuss the ratio of CH4 to CO2 in stack based emissions as it relates to our calculated emission rates and as compared to the same ratio for the emission factors.
Firing a Weapon and Killing In Combat Are Associated with Suicidal Ideation in OEF/OIF Veterans
Tripp, Jessica C.; McDevitt-Murphy, Meghan E.; Henschel, Aisling V.
2016-01-01
Objective Combat veterans are at risk for several adverse outcomes such as posttraumatic stress disorder (PTSD), depression, hazardous alcohol use, and most critically, suicidal behaviors. The high rate of suicide in veterans has been understood as a correlate of PTSD and depression, but it is possible that certain specific types of combat experiences may lead to suicidal behaviors. Acts committed by the veteran in the context of war such as killing may evoke a “moral injury,” which leads to thoughts of ending one’s life. Method The present exploratory research examined relationships between combat experiences and suicidal ideation (SI) and PTSD in a sample of 68 OEF/OIF veterans (91% male, mean age = 32.31 years) who had screened positive for alcohol misuse. We examined firing a weapon/killing in combat (Firing/Killing) and killing in combat (Killing) alone as predictors of (SI) and PTSD severity in both the full sample, and in analyses that examined men only. Results Firing/Killing were associated with SI for the full sample and men only, and Killing showed a trend towards significance in predicting SI. Hierarchical regression analyses suggested that Firing/Killing did not predict PTSD for the full sample or men only, but Killing was predictive of PTSD for both samples. Conclusions These results indicate that there may be differences in Firing/Killing and Killing alone in OEF/OIF veterans who screened positive for alcohol misuse. Thorough screening of combat experiences and addressing moral injury in returning combat veterans may help reduce high rates of suicide and PTSD. PMID:26460495
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pavlish, John; Thompson, Jeffrey; Dunham, Grant
2014-09-30
Owners of fossil fuel-fired power plants face the challenge of measuring stack emissions of trace metals and acid gases at much lower levels than in the past as a result of increasingly stringent regulations. In the United States, the current reference methods for trace metals and halogens are wet-chemistry methods, U.S. Environmental Protection Agency (EPA) Methods 29 and 26 or 26A, respectively. As a possible alternative to the EPA methods, the Energy & Environmental Research Center (EERC) has developed a novel multielement sorbent trap (MEST) method to be used to sample for trace elements and/or halogens. Sorbent traps offer amore » potentially advantageous alternative to the existing sampling methods, as they are simpler to use and do not require expensive, breakable glassware or handling and shipping of hazardous reagents. Field tests comparing two sorbent trap applications (MEST-H for hydrochloric acid and MEST-M for trace metals) with the reference methods were conducted at two power plant units fueled by Illinois Basin bituminous coal. For hydrochloric acid, MEST measured concentrations comparable to EPA Method 26A at two power plant units, one with and one without a wet flue gas desulfurization scrubber. MEST-H provided lower detection limits for hydrochloric acid than the reference method. Results from a dry stack unit had better comparability between methods than results from a wet stack unit. This result was attributed to the very low emissions in the latter unit, as well as the difficulty of sampling in a saturated flue gas. Based on these results, the MEST-H sorbent traps appear to be a good candidate to serve as an alternative to Method 26A (or 26). For metals, the MEST trap gave lower detection limits compared to EPA Method 29 and produced comparable data for antimony, arsenic, beryllium, cobalt, manganese, selenium, and mercury for most test runs. However, the sorbent material produced elevated blanks for cadmium, nickel, lead, and chromium at levels that would interfere with accurate measurement at U.S. hazardous air pollutant emission limits for existing coal-fired power plant units. Longer sampling times employed during this test program did appear to improve comparative results for these metals. Although the sorbent contribution to the sample was reduced through improved trap design, additional research is still needed to explore lower-background materials before the MEST-M application can be considered as a potential alternative method for all of the trace metals. This subtask was funded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the Electric Power Research Institute, the Illinois Clean Coal Institute, Southern Illinois Power Company, and the Center for Air Toxic Metals Affiliates Program.« less
Trace gas emissions from a mid-latitude prescribed chaparral fire
Wesley R. Cofer; Joel S. Levine; Philip J. Riggan; Daniel I. Sebacher; Edward L. Winstead; Shaw Edwin F.; James A. Brass; Vincent. G. Ambrosia
1988-01-01
Gas samples were collected in smoke plumes over the San Dimas Experimental Forest during a 400-acre prescribed chaparral fire on December 12, 1986. A helicopter was used to collect gas samples over areas of vigorous flaming combustion and over areas of mixed stages (vigorous/transitional/smoldering) of combustion. Sampling was conducted at altitudes as low as 35 m and...
Propellant Residues Deposition from Firing of 40-mm Grenades
2010-09-01
the snow surface downrange of the firing positions in three sampling units on each pad. Samples were analyzed and results compo- sited to derive an...Processing and Analysis ..................................................................... 10 3.1 Snow samples...mm howitzers, propel- lant residues containing DNT were collected from the snow -covered area in front of one of the guns (Walsh, M.E. et al. 2004
Robert E. Keane; Laura J. Dickinson
2007-01-01
Fire managers need better estimates of fuel loading so they can more accurately predict the potential fire behavior and effects of alternative fuel and ecosystem restoration treatments. This report presents a new fuel sampling method, called the photoload sampling technique, to quickly and accurately estimate loadings for six common surface fuel components (1 hr, 10 hr...
Abraham, Joji; Dowling, Kim; Florentine, Singarayer
2018-01-01
Prescribed fire conducted in fire-prone areas is a cost-effective choice for forest management, but it also affects many of the physicochemical and bio-geological properties of the forest soil, in a similar manner to wild fires. The aim of this study is to investigate the nature of the mercury mobilization after a prescribed fire and the subsequent temporal changes in concentration. A prescribed fire was conducted in a legacy mine site in Central Victoria, Australia, in late August 2015 and soil sample collection and analyses were carried out two days before and two days after the fire, followed by collection at the end of each season and after an intense rainfall event in September 2016. Results revealed the occurrence of mercury volatilization (8.3-97%) during the fire, and the mercury concentration displayed a significant difference (p < 0.05) before and immediately after the fire. Integrated assessment with number of pollution indices has shown that the study site is extremely contaminated with mercury during all the sampling events, and this poses a serious ecological risk due to the health impacts of mercury on human and ecosystems. In times of climate fluctuation with concomitant increase in forest fire (including prescribed fire), and subsequent precipitation and runoff, the potential for an increased amount of mercury being mobilized is of heighted significance. Therefore, it is recommended that prescribed fire should be cautiously considered as a forest management strategy in any mercury affected landscapes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Moya, D; González-De Vega, S; García-Orenes, F; Morugán-Coronado, A; Arcenegui, V; Mataix-Solera, J; Lucas-Borja, M E; De Las Heras, J
2018-05-28
Despite Mediterranean ecosystems' high resilience to fire, both climate and land use change, and alterations in fire regimes increase their vulnerability to fire by affecting the long-term natural recovery of ecosystem services. The objective of this work is to study the effects of fire severity on biochemical soil indicators, such as chemical composition or enzymatic activity, related to time after fire and natural vegetation recovery (soil-plant interphase). Soil samples from three wildfires occurring 3, 15 and 21 years ago were taken in the south-eastern Iberian Peninsula (semiarid climate). Sampling included three fire severity levels in naturally regenerated (and changing to shrublands) Pinus halepensis Mill. forests. In the short-term post-fire period, phosphorus concentration, electrical conductivity and urease activity were positively linked to fire severity, and also influenced β-glucosidade activity in a negative relationship. During the 15-21-year post-fire period, the effects related to medium-high fire severity were negligible and soil quality indicators were linked to natural regeneration success. The results showed that most soil properties recovered in the long term after fire (21 years). These outcomes will help managers and stakeholders to implement management tools to stabilise soils and to restore burned ecosystems affected by medium-high fire severity. Such knowledge can be considered in adaptive forest management to reduce the negative effects of wildfires and desertification, and to improve the resilience of vulnerable ecosystems in a global change scenario. Copyright © 2018 Elsevier B.V. All rights reserved.
Remote sensing sensitivity to fire severity and fire recovery
Key, C.H.
2005-01-01
The paper examines fundamental ways that geospatial data on fire severity and recovery are influenced by conditions of the remote sensing. Remote sensing sensitivities are spatial, temporal and radiometric in origin. Those discussed include spatial resolution, the sampling time of year, and time since fire. For standard reference, sensitivities are demonstrated with examples drawn from an archive of burn assessments based on one radiometric index, the differenced Normalized Burn Ratio. Resolution determines the aggregation of fire effects within a pixel (alpha variation), hence defining the detected ecological response, and controlling the ability to determine patchiness and spatial distribution of responses throughout a burn (beta variation). As resolution decreases, alpha variation increases, extracting beta variation from the complexity of the whole burn. Seasonal timing impacts the radiometric quality of data in terms of transmittance, sun angle, and potential for enhanced contrast between responses within burns. Remote sensing sensitivity can degrade during many fire seasons when snow, incomplete burning, hazy conditions, low sun angles, or extended drought are common. Time since fire (lag timing) most notably shapes severity detection through the first-order fire effects evident in survivorship and delayed mortality that emerge by the growth period after fire. The former effects appear overly severe at first, but diminish, as burned vegetation remains viable. Conversely, the latter signals vegetation that appears healthy at first, but is damaged by heat to the extent that it soon dies. Both responses can lead to either over- or under-estimating severity, respectively, depending on fire behavior and pre-fire composition unique to each burned area. Based on implications of such sensitivities, three sampling intervals for short-term burn severity are identified; rapid, initial, and extended assessment, sampled within ca. two weeks, two months, and depending on the ecotype, from three months to one year after fire, respectively. Jointly, remote sensing conditions and the way burns are studied yield different tendencies for data quality and information content that impact the objectives and hypotheses that can be studied. Such considerations can be commonly overlooked, but need to be incorporated especially in comparative studies, and to build long-term reference databases on fire severity and recovery.
Cytosolic Calcium Coordinates Mitochondrial Energy Metabolism with Presynaptic Activity
Chouhan, Amit K.; Ivannikov, Maxim V.; Lu, Zhongmin; Sugimori, Mutsuyuki; Llinas, Rodolfo R.; Macleod, Gregory T.
2012-01-01
Most neurons fire in bursts, imposing episodic energy demands, but how these demands are coordinated with oxidative phosphorylation is still unknown. Here, using fluorescence imaging techniques on presynaptic termini of Drosophila motor neurons (MNs), we show that mitochondrial matrix pH (pHm), inner membrane potential (Δψm), and NAD(P)H levels ([NAD(P)H]m) increase within seconds of nerve stimulation. The elevations of pHm, Δψm, and [NAD(P)H]m indicate an increased capacity for ATP production. Elevations in pHm were blocked by manipulations which blocked mitochondrial Ca2+ uptake, including replacement of extracellular Ca2+ with Sr2+, and application of either tetraphenylphosphonium chloride or KB-R7943, indicating that it is Ca2+ that stimulates presynaptic mitochondrial energy metabolism. To place this phenomenon within the context of endogenous neuronal activity, the firing rates of a number of individually identified MNs were determined during fictive locomotion. Surprisingly, although endogenous firing rates are significantly different, there was little difference in presynaptic cytosolic Ca2+ levels ([Ca2+]c) between MNs when each fires at its endogenous rate. The average [Ca2+]c level (329±11nM) was slightly above the average Ca2+ affinity of the mitochondria (281±13nM). In summary, we show that when MNs fire at endogenous rates [Ca2+]c is driven into a range where mitochondria rapidly acquire Ca2+. As we also show that Ca2+ stimulates presynaptic mitochondrial energy metabolism, we conclude that [Ca2+]c levels play an integral role in coordinating mitochondrial energy metabolism with presynaptic activity in Drosophila MNs. PMID:22279208
Grabinski, Christin M; Methner, Mark M; Jackson, Jerimiah M; Moore, Alexander L; Flory, Laura E; Tilly, Trevor; Hussain, Saber M; Ott, Darrin K
2017-06-01
U.S. Air Force small arms firing ranges began using copper-based, lead-free frangible ammunition in the early 2000s due to environmental and health concerns related to the use of lead-based ammunition. Exposure assessments at these firing ranges have routinely detected chemicals and metals in amounts much lower than their mass-based occupational exposure limits, yet, instructors report work-related health concerns including respiratory distress, nausea, and headache. The objective of this study at one firing range was to characterize the aerosol emissions produced by weapons during firing events and evaluate the ventilation system's effectiveness in controlling instructor exposure to these emissions. The ventilation system was assessed by measuring the range static air pressure differential and the air velocity at the firing line. Air flow patterns were near the firing line. Instructor exposure was sampled using a filter-based air sampling method for metals and a wearable, real-time ultrafine particle counter. Area air sampling was simultaneously performed to characterize the particle size distribution, morphology, and composition. In the instructor's breathing zone, the airborne mass concentration of copper was low (range = <1 µg/m 3 to 16 µg/m 3 ), yet the ultrafine (nanoscale) particle number concentration increased substantially during each firing event. Ultrafine particles contained some copper and were complex in morphology and composition. The ventilation assessment found that the average velocity across all shooting lanes was acceptable compared to the recommended guideline (20% of the ideal 0.38 m/s (75 ft/min). However, uniform, downrange airflow pattern requirements were not met. These results suggest that the mass-based occupational exposure limits, as applied to this environment, may not be protective enough to eliminate health complaints reported by instructors whose full-time job involves training personnel on weapons that fire lead-free frangible ammunition. Using an ultrafine particle counter appears to be an alternative method of assessing ventilation effectiveness in removing ultrafine particulate produced during firing events.
2004-01-01
forests, alpine forests, and so forth); (2) had a range of sampling frequency and dura- tion, such as during and immediately following a fire (from the...1) were done in a variety of environments (savannas, grass- lands, temperate forests, alpine forests, and so forth), (2) had a range of sampling...of Nutrients in Surface Waters Gresswell, R.E., 1999, Fire and aquatic ecosystems in forested biomes of North America: Transactions of the American
Planning for prescribed burning in the inland northwest.
Robert E. Martin; John D. Dell
1978-01-01
Fire has historically played a role in forests and ranges of the inland Northwest. This guide has been prepared to help managers understand the role of fire and the potential uses of fire and to plan for fire use in managing these lands. Sections deal with these topics, and steps in planning a prescribed burn are outlined. A sample burning situation illustrates the...
R. J. Yokelson; T. J. Christian; T. G. Karl; A. Guenther
2008-01-01
As part of the Tropical Forest and Fire Emissions Experiment (TROFFEE), tropical forest fuels were burned in a large, biomass-fire simulation facility and the smoke was characterized with open-path Fourier transform infrared spectroscopy (FTIR), proton-transfer reaction mass spectrometry (PTR-MS), gas chromatography (GC), GC/PTRMS, and filter sampling of the particles...
Prescribed fire effects on the herbaceous layer of mixed-oak forests
Todd F. Hutchinson; Ralph E.J. Boerner; Steve Sutherland; Elaine Kennedy Sutherland; Marilyn Ortt; Louis R. Iverson; Louis R. Iverson
2005-01-01
In 1994, a multidisciplinary project was established to study the effects of prescribed fire on oak forests in southern Ohio. Here we describe the herbaceous layer response to fires over a 5-year period. In four study sites, treatments imposed were unburned, periodic (1996 and 1999), and annual (1996-1999) fires. Sample plots (n = 108) were stratified by an integrated...
The Interaction between Juvenile School Fire Setting and Bullying: An Exploratory Study
ERIC Educational Resources Information Center
Sharp, Amy; Roe-Sepowitz, Dominique; Boberg, Janet
2009-01-01
The aim of this study is to provide school social workers with an outline of the indicators common to school fire setters regarding their experiences of bullying and victimization by bullies. A sample of juvenile fire setters (N = 379) between the ages of five and seventeen years attending a fire-setter intervention program completed a modified…
Forest Fire History... A Computer Method of Data Analysis
Romain M. Meese
1973-01-01
A series of computer programs is available to extract information from the individual Fire Reports (U.S. Forest Service Form 5100-29). The programs use a statistical technique to fit a continuous distribution to a set of sampled data. The goodness-of-fit program is applicable to data other than the fire history. Data summaries illustrate analysis of fire occurrence,...
NASA Technical Reports Server (NTRS)
Schmalzer, Paul A.; Hinkle, C. Ross
1987-01-01
Four stands of oak scrub two, four, eight, and 25 years since fire were sampled with permanent 15 m line transects. Percent cover by species was determined. Plant samples were analyzed for a variety of substances. Transects were resurveyed in 1985 for vegetation parameters. Nutrient pools in biomass were calculated from biomass data and tissue nutrient concentrations. Soil nutrient pools were calculated from nutrient concentrations and bulk density. Species distribution and soil chemical properties were found to be closely related to water table depth. The following fire-related conclusions are reached: (1) major structural changes occur in scrub after fire in that shrub height is reduced and requires four to six years to exceed 1 m; (2) reduction in shrub height affects the suitability of scrub for the Florida scrub jay (3) live biomass increases with time since fire; (4) nutrient concentrations in live biomass do not change with time since fire; (5) species composition and richness are little changed after fire; and (6) imposition of a continued regime of burning on a three-year cycle may have adverse impacts not indicated by the recovery of scrub from a single fire.
NASA Astrophysics Data System (ADS)
Azieyanti, N. A.; Hakim, Alif; Hasini, Hasril
2017-10-01
A composite mixture of gypsum and natural fibers has been considered in this study to enhance the fire resistance rating of a fire door. Previously the materials used to make a fire door are gypsum and fiber wool where it acts as a protective coating. Normally this fire door must be compact and able to close on its own. Natural fibers have the ability to replace glass fiber cotton because of its features that are available in fiber glass wool. When using fiberglass, it can cause health problem once it is swallowed and inhaled, and may remain in the lungs indefinitely. It also can contribute to lungs cancer. Kapok fiber has been used in this experiment as natural fibers. The objective of the experiment is to analyze the fire resistant rating of the composite mixture of gypsum with kapok fiber. The scopes of the experiment consist of a preparation of composite mixture samples of gypsum with kapok fiber with different composition and thickness, and the fabrication of a fire resistant testing furnace. A testing of samples which were conducted in accordance with the standard MS 1073: PART 2:1996.
Prevention of Surgical Fires: A Certification Course for Healthcare Providers.
Fisher, Marquessa
2015-08-01
An estimated 550 to 650 surgical fires occur annually in the United States. Surgical fires may have severe consequences, including burns, disfigurement, long-term medical care, or death. This article introduces a potential certification program for the prevention of surgical fires. A pilot study was conducted with a convenience sample of 10 anesthesia providers who participated in the education module. The overall objective was to educate surgical team members and to prepare them to become certified in surgical fire prevention. On completion of the education module, participants completed the 50-question certification examination. The mean pretest score was 66%; none of the participants had enough correct responses (85%) to be considered competent in surgical fire prevention. The mean post- test score was 92.80%, with all participants answering at least 85% of questions correct. A paired-samples t test showed a statistically significant increase in knowledge: t (df = 9) = 11.40; P = .001. Results of the pilot study indicate that this course can remediate gaps in knowledge of surgical fire prevention for providers. Their poor performance on the pretest suggests that many providers may not receive sufficient instruction in surgical fire prevention.
NASA Astrophysics Data System (ADS)
Rowell, Eric Martin
The primary goal of this research is to advance methods for deriving fine-grained, scalable, wildland fuels attributes in 3-dimensions using terrestrial and airborne laser scanning technology. It is fundamentally a remote sensing research endeavor applied to the problem of fuels characterization. Advancements in laser scanning are beginning to have significant impacts on a range of modeling frameworks in fire research, especially those utilizing 3-dimensional data and benefiting from efficient data scaling. The pairing of laser scanning and fire modeling is enabling advances in understanding how fuels variability modulates fire behavior and effects. This dissertation details the development of methods and techniques to characterize and quantify surface fuelbeds using both terrestrial and airborne laser scanning. The primary study site is Eglin Airforce Base, Florida, USA, which provides a range of fuel types and conditions in a fire-adapted landscape along with the multi-disciplinary expertise, logistical support, and prescribed fire necessary for detailed characterization of fire as a physical process. Chapter 1 provides a research overview and discusses the state of fuels science and the related needs for highly resolved fuels data in the southeastern United States. Chapter 2, describes the use of terrestrial laser scanning for sampling fuels at multiple scales and provides analysis of the spatial accuracy of fuelbed models in 3-D. Chapter 3 describes the development of a voxel-based occupied volume method for predicting fuel mass. Results are used to inform prediction of landscape-scale fuel load using airborne laser scanning metrics as well as to predict post-fire fuel consumption. Chapter 4 introduces a novel fuel simulation approach which produces spatially explicit, statistically-defensible estimates of fuel properties and demonstrates a pathway for resampling observed data. This method also can be directly compared to terrestrial laser scanning data to assess how energy interception of the laser pulse affects characterization of the fuelbed. Chapter 5 discusses the contribution of this work to fire science and describes ongoing and future research derived from this work. Chapters 2 and 4 have been published in International Journal of Wildland Fire and Canadian Journal of Remote Sensing, respectively, and Chapter 3 is in preparation for publication.
NASA Astrophysics Data System (ADS)
Clark, James S.
1988-07-01
Results of stratigraphic charcoal analysis from thin sections of varved lake sediments have been compared with fire scars on red pine trees in northwestern Minnesota to determine if charcoal data accurately reflect fire regimes. Pollen and opaque-spherule analyses were completed from a short core to confirm that laminations were annual over the last 350 yr. A good correspondence was found between fossil-charcoal and fire-scar data. Individual fires could be identified as specific peaks in the charcoal curves, and times of reduced fire frequency were reflected in the charcoal data. Charcoal was absent during the fire-suppression era from 1920 A.D. to the present. Distinct charcoal maxima from 1864 to 1920 occurred at times of fire within the lake catchment. Fire was less frequent during the 19th century, and charcoal was substantially less abundant. Fire was frequent from 1760 to 1815, and charcoal was abundant continuously. Fire scars and fossil charcoal indicate that fires did not occur during 1730-1750 and 1670-1700. Several fires occurred from 1640 to 1670 and 1700 to 1730. Charcoal counted from pollen preparations in the area generally do not show this changing fire regime. Simulated "sampling" of the thin-section data in a fashion comparable to pollen-slide methods suggests that sampling alone is not sufficient to account for differences between the two methods. Integrating annual charcoal values in this fashion still produced much higher resolution than the pollen-slide method, and the postfire suppression decline of charcoal characteristic of my method (but not of pollen slides) is still evident. Consideration of the differences in size of fragments counted by the two methods is necessary to explain charcoal representation in lake sediments.
Release of volatile and semi-volatile toxicants during house fires.
Hewitt, Fiona; Christou, Antonis; Dickens, Kathryn; Walker, Richard; Stec, Anna A
2017-04-01
Qualitative results are presented from analysis of volatile and semi-volatile organic compounds (VOCs/SVOCs) obtained through sampling of gaseous effluent and condensed particulates during a series of experimental house fires conducted in a real house. Particular emphasis is given to the 16 polycyclic aromatic hydrocarbons (PAHs) listed by the Environmental Protection Agency due to their potentially carcinogenic effects. The initial fuel packages were either cooking oil or a single sofa; these were burned both alone, and in furnished surroundings. Experiments were performed at different ventilation conditions. Qualitative Gas Chromatography-Mass Spectrometry (GC-MS) analysis found VOC/SVOC releases in the developing stages of the fires, and benzo(a)pyrene - the most carcinogenic PAH - was found in at least one sampling interval in the majority of fires. A number of phosphorus fire retardants were detected, in both the gaseous effluent and particulates, from fires where the initial fuel source was a sofa. Their release during the fire is significant as they pose toxicological concerns separate from those presented by the PAHs. Copyright © 2016. Published by Elsevier Ltd.
Shinneman, Douglas; McIlroy, Susan
2016-01-01
Sagebrush steppe of North America is considered highly imperilled, in part owing to increased fire frequency. Sagebrush ecosystems support numerous species, and it is important to understand those factors that affect rates of post-fire sagebrush recovery. We explored recovery of Wyoming big sagebrush (Artemisia tridentata ssp.wyomingensis) and basin big sagebrush (A. tridentata ssp. tridentata) communities following fire in the northern Columbia Basin (Washington, USA). We sampled plots across 16 fires that burned in big sagebrush communities from 5 to 28 years ago, and also sampled nearby unburned locations. Mixed-effects models demonstrated that density of large–mature big sagebrush plants and percentage cover of big sagebrush were higher with time since fire and in plots with more precipitation during the winter immediately following fire, but were lower when precipitation the next winter was higher than average, especially on soils with higher available water supply, and with greater post-fire mortality of mature big sagebrush plants. Bunchgrass cover 5 to 28 years after fire was predicted to be lower with higher cover of both shrubs and non-native herbaceous species, and only slightly higher with time. Post-fire recovery of big sagebrush in the northern Columbia Basin is a slow process that may require several decades on average, but faster recovery rates may occur under specific site and climate conditions.
Arthur R. Tiedemann; Paul M. Woodard
2002-01-01
A stand-replacement prescribed fire in an over-mature lodgepole pine (Pinus contorta Dougl. ex Loud.)-subalpine fir (Abies lasiocarpa (Hook.) Nutt.) stand (snag area) and in a mature lodgepole pine thicket (thicket area) resulted in lower plant diversity within the first year after burning, and as fire energy outputs increased...
Turbulent kinetic energy during wildfires in the north central and north-eastern US
Warren E. Heilman; Xindi Bian
2010-01-01
The suite of operational fire-weather indices available for assessing the atmospheric potential for extreme fire behaviour typically does not include indices that account for atmospheric boundary-layer turbulence or wind gustiness that can increase the erratic behaviour of fires. As a first step in testing the feasibility of using a quantitative measure of turbulence...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Rod
FIRETEC presents a new way of studying fire and learning how to better manage and cope with it. The model provides additional scientific input for decisions by policymakers working in land management, water resources and energy. The team hopes it will eventually assist fire and fuel management operations. This research is done in partnership with the USDA Forest Service, Air Force Wildland Fire Center, INRA and Canadian Forest Service.
Superconductivity devices: Commercial use of space
NASA Technical Reports Server (NTRS)
Haertling, Gene; Furman, Eugene; Hsi, Chi-Shiung; Li, Guang
1993-01-01
A YBCO thick film containing 20 percent Ag2O with a T(sub c) of 86.8 K and J(sub c) of 108 A/sq cm was obtained. The film was fabricated by a two-step firing process, i.e., firing the film at 1000 C for 10 minutes and annealing at 970 C for 30 minutes. The two-step firing process, however, was not suitable for the multiple-lead YBCO sample due to the formation of the 211 green phase at 1000 C in the multiple-lead YBCO sample. A BSCCO thick film printed on a MgO coated MSZ substrate and fired at 845 C for 2 hours exhibited a superconducting behavior at 89 K. Because of its porous microstructure, the critical current density of the BSCCO thick film was limited. This report also includes the results of the YBCO and BSCCO materials used as oxide electrodes for ferroelectric materials. The YBCO electroded PLZT showed higher remanent polarization and coercive field than the sample electroded with silver paste. A higher Curie temperature for the PLZT was obtained from the YBCO electroded sample. The BSCCO electroded sample, however, exhibited the same Curie temperature as that of a silver electroded sample. Dissipation factors of the ferroelectric samples increased when the oxide electrode was applied.
Emissions During Co-Firing of RDF-5 with Coal in a 22 t/h Steam Bubbling Fluidized Bed Boiler
NASA Astrophysics Data System (ADS)
Wan, Hou-Peng; Chen, Jia-Yuan; Juch, Ching-I.; Chang, Ying-Hsi; Lee, Hom-Ti
The co-firing of biomass and fossil fuel in the same power plant is one of the most important issues when promoting the utilization of renewable energy in the world. Recently, the co-firing of coal together with biomass fuel, such as "densified refuse derived fuel" (d-RDF or RDF-5) or RPF (refuse paper & plastic fuel) from waste, has been considered as an environmentally sound and economical approach to both waste remediation and energy production in the world. Because of itscomplex characteristics when compared to fossil fuel, potential problems, such as combustion system stability, the corrosion of heat transfer tubes, the qualities of the ash, and the emissionof pollutants, are major concerns when co-firing the biomass fuel with fossil fuel in a traditional boiler. In this study, co-firing of coal with RDF-5 was conducted in a 22t/h bubbling fluidized bed (BFB) steam boiler to investigate the feasibility of utilizing RDF-5 as a sustainable fuels in a commercial coal-fired steam BFB boiler. The properties of the fly ash, bottom ash, and the emission of pollutants are analyzed and discussed in this study.
NASA Technical Reports Server (NTRS)
Ichoku, Charles; Giglio, Louis; Wooster, Martin J.; Remer, Lorraine A.
2008-01-01
Remote sensing is the most practical means of measuring energy release from large open-air biomass burning. Satellite measurement of fire radiative energy (FRE) release rate or power (FRP) enables distinction between fires of different strengths. Based on a 1-km resolution fire data acquired globally by the MODerate-resolution Imaging Spectro-radiometer (MODIS) sensor aboard the Terra and Aqua satellites from 2000 to 2006, instanteaneous FRP values ranged between 0.02 MW and 1866 MW, with global daily means ranging between 20 and 40 MW. Regionally, at the Aqua-MODIS afternoon overpass, the mean FRP values for Alaska, Western US, Western Australia, Quebec and the rest of Canada are significantly higher than these global means, with Quebec having the overall highest value of 85 MW. Analysis of regional mean FRP per unit area of land (FRP flux) shows that a peak fire season in certain regions, fires can be responsible for up to 0.2 W/m(sup 2) at peak time of day. Zambia has the highest regional monthly mean FRP flux of approximately 0.045 W/m(sup 2) at peak time of day and season, while the Middle East has the lowest value of approximately 0.0005 W/m(sup 2). A simple scheme based on FRP has been devised to classify fires into five categories, to facilitate fire rating by strength, similar to earthquakes and hurricanes. The scheme uses MODIS measurements of FRP at 1-km resolution as follows: catagory 1 (less than 100 MW), category 2 (100 to less than 500 MW), category 3 (500 to less than 1000 MW), category 4 (1000 to less than 1500 MW), catagory 5 (greater than or equal to 1500 MW). In most regions of the world, over 90% of fires fall into category 1, while only less than 1% fall into each of categories 3 to 5, although these proportions may differ significantly from day to day and by season. The frequency of occurence of the larger fires is region specific, and could not be explained by ecosystem type alone. Time-series analysis of the propertions of higher category fires based on MODIS measured FRP from 2002 to 2006 does not show any moticeable trend because of the short time period.
Shoulder-Fired Weapons with High Recoil Energy: Quantifying Injury and Shooting Performance
2004-05-01
USARIEM TECHNICAL REPORT T04-05 SHOULDER-FIRED WEAPONS WITH HIGH RECOIL ENERGY: QUANTIFYING INJURY AND SHOOTING PERFORMANCE...ACKNOWLEDGMENTS The authors would like to thank the following individuals for their assistance in preparing this technical report: Robert Mello... myofascial and other musculoskeletal pain is considered abnormal if the anatomical site is 2 kg/cm2 lower relative to a normal control point, such as
FR Performance of New Fire-off on PET/CO blend fabrics
NASA Astrophysics Data System (ADS)
Atakan, R.; Çelebi, E.; Ozcan, G.; Soydan, N.; Sarac, A. S.
2017-10-01
This paper represents the investigation on flame retardancy performance and durability of polyester/cotton (P/C) fabrics treated with a novel halogen/formaldehyde free, P-N synergetic FR finishing agent called New Fire-off. 100 % Cotton, 100 % Polyester and three different blend P/C fabrics were chosen in this study. Fabric samples were treated with New Fire-off through pad-dry-cure process. Flammability and thermal properties of the treated samples with New Fire-off were tested according to relevant ISO standard and procedures. The obtained results showed that this new finishing formulation is a good char-forming agent. However, further studies are required to achieve washing durability for the P/C blends.
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuels consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.
Aggregated particles caused by instrument artifact
NASA Astrophysics Data System (ADS)
Pierce, Ashley M.; Loría-Salazar, S. Marcela; Arnott, W. Patrick; Edwards, Grant C.; Miller, Matthieu B.; Gustin, Mae S.
2018-04-01
Previous studies have indicated that superaggregates, clusters of aggregates of soot primary particles, can be formed in large-scale turbulent fires. Due to lower effective densities, higher porosity, and lower aerodynamic diameters, superaggregates may pass through inlets designed to remove particles < 2.5 µm in aerodynamic diameter (PM2.5). Ambient particulate matter samples were collected at Peavine Peak, NV, USA (2515 m) northwest of Reno, NV, USA from June to November 2014. The Teledyne Advanced Pollution Instrumentation (TAPI) 602 BetaPlus particulate monitor was used to collect PM2.5 on two filter types. During this time, aggregated particles > 2.5 µm in aerodynamic diameter were collected on 36 out of 158 sample days. On preliminary analysis, it was thought that these aggregated particles were superaggregates, depositing past PM10 (particles < 10 µm in aerodynamic diameter) pre-impactors and PM2.5 cyclones. However, further analysis revealed that these aggregated particles were dissimilar to superaggregates observed in previous studies, both in morphology and in elemental composition. To determine if the aggregated particles were superaggregates or an instrument artifact, samples were investigated for the presence of certain elements, the occurrence of fires, high relative humidity and wind speeds, as well as the use of generators on site. Samples with aggregated particles, referred to as aggregates, were analyzed using a scanning electron microscope for size and shape and energy dispersive X-ray spectroscopy was used for elemental analysis. It was determined, based on the high amounts of aluminum present in the aggregate samples, that a sampling artifact associated with the sample inlet and prolonged, high wind events was the probable reason for the observed aggregates.
Poster Session- Extended Abstracts
Jack D. Alexander III; Jean Findley; Brenda K. Kury; Jan L. Beyers; Douglas S. Cram; Terrell T. Baker; Jon C. Boren; Carl Edminster; Sue A. Ferguson; Steven McKay; David Nagel; Trent Piepho; Miriam Rorig; Casey Anderson; Jeanne Hoadley; Paulette L. Ford; Mark C. Andersen; Ed L. Fredrickson; Joe Truett; Gary W. Roemer; Brenda K. Kury; Jennifer Vollmer; Christine L. May; Danny C. Lee; James P. Menakis; Robert E. Keane; Zhi-Liang Zhu; Carol Miller; Brett Davis; Katharine Gray; Ken Mix; William P. Kuvlesky Jr.; D. Lynn Drawe; Marcia G. Narog; Roger D. Ottmar; Robert E. Vihnanek; Clinton S. Wright; Timothy E. Paysen; Burton K. Pendleton; Rosemary L. Pendleton; Carleton S. White; John Rogan; Doug Stow; Janet Franklin; Jennifer Miller; Lisa Levien; Chris Fischer; Emma Underwood; Robert Klinger; Peggy Moore; Clinton S. Wright
2008-01-01
Titles found within Poster Session-Extended Abstracts include:Assessment of emergency fire rehabilitation of four fires from the 2000 fire season on the Vale, Oregon, BLM district: review of the density sampling materials and methods: p. 329Â Growth of regreen, seeded for erosion control, in the...
Impact of the buildings areas on the fire incidence.
Srekl, Jože; Golob, Janvit
2010-03-01
A survey of statistical studies shows that probability of fires is expressed by the equation P(A) = KAα, where A = total floor area of the building and K and are constants for an individual group, or risk category. This equation, which is based on the statistical data on fires in Great Britain, does not include the impact factors such as the number of employees and the activities carried out in these buildings. In order to find out possible correlations between the activities carried out in buildings, the characteristics of buildings and number of fires, we used a random sample which included 134 buildings as industrial objects, hotels, restaurants, warehouses and shopping malls. Our study shows that the floor area of buildings has low impact on the incidence of fires. After analysing the sample of buildings by using multivariate analysis we proved a correlation between the number of fires, floor area of objects, work operation period (per day) and the number of employees in objects.
Fettig, Ina; Krüger, Simone; Deubel, Jan H; Werrel, Martin; Raspe, Tina; Piechotta, Christian
2014-05-01
The chemical analysis of fire debris represents a crucial part in fire investigations to determine the cause of a fire. A headspace solid-phase microextraction (HS-SPME) procedure for the detection of ignitable liquids in fire debris using a fiber coated with a mixture of three different sorbent materials (Divinylbenzene/Carboxen/Polydimethylsiloxane, DVB/CAR/PDMS) is described. Gasoline and diesel fuel were spiked upon a preburnt matrix (wood charcoal), extracted and concentrated with HS-SPME and then analyzed with gas chromatography/mass spectrometry (GC/MS). The experimental conditions--extraction temperature, incubation and exposure time--were optimized. To assess the applicability of the method, fire debris samples were prepared in the smoke density chamber (SDC) and a controlled-atmosphere cone calorimeter. The developed methods were successfully applied to burnt particleboard and carpet samples. The results demonstrate that the procedure that has been developed here is suitable for detecting these ignitable liquids in highly burnt debris. © 2013 American Academy of Forensic Sciences.
46 CFR 164.007-9 - Procedure for approval.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the Fire Research section of the National Bureau of Standards, Washington, DC 20234, and shall advise.... (1) If the manufacturer desires to have the test conducted at some laboratory other than the National... sample or samples for the fire resistance test will be given at this time, together with the estimated...
46 CFR 164.007-9 - Procedure for approval.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the Fire Research section of the National Bureau of Standards, Washington, DC 20234, and shall advise.... (1) If the manufacturer desires to have the test conducted at some laboratory other than the National... sample or samples for the fire resistance test will be given at this time, together with the estimated...
Modeling the effects of vegetation heterogeneity on wildland fire behavior
NASA Astrophysics Data System (ADS)
Atchley, A. L.; Linn, R.; Sieg, C.; Middleton, R. S.
2017-12-01
Vegetation structure and densities are known to drive fire-spread rate and burn severity. Many fire-spread models incorporate an average, homogenous fuel density in the model domain to drive fire behavior. However, vegetation communities are rarely homogenous and instead present significant heterogeneous structure and fuel densities in the fires path. This results in observed patches of varied burn severities and mosaics of disturbed conditions that affect ecological recovery and hydrologic response. Consequently, to understand the interactions of fire and ecosystem functions, representations of spatially heterogeneous conditions need to be incorporated into fire models. Mechanistic models of fire disturbance offer insight into how fuel load characterization and distribution result in varied fire behavior. Here we use a physically-based 3D combustion model—FIRETEC—that solves conservation of mass, momentum, energy, and chemical species to compare fire behavior on homogenous representations to a heterogeneous vegetation distribution. Results demonstrate the impact vegetation heterogeneity has on the spread rate, intensity, and extent of simulated wildfires thus providing valuable insight in predicted wildland fire evolution and enhanced ability to estimate wildland fire inputs into regional and global climate models.
Geology of coal fires: case studies from around the world
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glenn B. Stracher
2008-01-15
Coal fires are preserved globally in the rock record as burnt and volume-reduced coal seams and by pyrometamorphic rocks, explosion breccias, clinker, gas-vent-mineral assemblages, fire-induced faulting, ground fissures, slump blocks, and sinkholes. Coal fires are responsible for coronary and respiratory diseases and fatalities in humans, as well as arsenic and fluorine poisoning. Their heat energy, toxic fumes, and solid by-products of combustion destroy floral and faunal habitats while polluting the air, water, and soil. This volume includes chapters devoted to spontaneous combustion and greenhouse gases, gas-vent mineralogy and petrology, paralavas and combustion metamorphic rocks, geochronology and landforms, magnetic signatures andmore » geophysical modeling, remote-sensing detection and fire-depth estimation of concealed fires, and coal fires and public policy.« less
Lovich, Jeffrey E.; Ennen, Joshua R.; Madrak, Sheila V.; Loughran, Caleb L.; Meyer, Katherin P.; Arundel, Terence R.; Bjurlin, Curtis D.
2011-01-01
We studied the long-term response of a cohort of eight female Agassiz’s desert tortoises (Gopherus agassizii) during the first 15 years following a large fire at a wind energy generation facility near Palm Springs, California, USA. The fire burned a significant portion of the study site in 1995. Tortoise activity areas were mapped using minimum convex polygons for a proximate post-fire interval from 1997 to 2000, and a long-term post-fire interval from 2009 to 2010. In addition, we measured the annual reproductive output of eggs each year and monitored the body condition of tortoises over time. One adult female tortoise was killed by the fire and five tortoises bore exposure scars that were not fatal. Despite predictions that tortoises would make the short-distance movements from burned to nearby unburned habitats, most activity areas and their centroids remained in burned areas for the duration of the study. The percentage of activity area burned did not differ significantly between the two monitoring periods. Annual reproductive output and measures of body condition remained statistically similar throughout the monitoring period. Despite changes in plant composition, conditions at this site appeared to be suitable for survival of tortoises following a major fire. High productivity at the site may have buffered tortoises from the adverse impacts of fire if they were not killed outright. Tortoise populations at less productive desert sites may not have adequate resources to sustain normal activity areas, reproductive output, and body conditions following fire.
Phenotypic plasticity of post-fire activity and thermal biology of a free-ranging small mammal.
Stawski, Clare; Körtner, Gerhard; Nowack, Julia; Geiser, Fritz
2016-05-15
Ecosystems can change rapidly and sometimes irreversibly due to a number of anthropogenic and natural factors, such as deforestation and fire. How individual animals exposed to such changes respond behaviourally and physiologically is poorly understood. We quantified the phenotypic plasticity of activity patterns and torpor use - a highly efficient energy conservation mechanism - in brown antechinus (Antechinus stuartii), a small Australian marsupial mammal. We compared groups in densely vegetated forest areas (pre-fire and control) with a group in a burned, open habitat (post-fire). Activity and torpor patterns differed among groups and sexes. Females in the post-fire group spent significantly less time active than the other groups, both during the day and night. However, in males only daytime activity declined in the post-fire group, although overall activity was also reduced on cold days in males for all groups. The reduction in total or diurnal activity in the post-fire group was made energetically possible by a ~3.4-fold and ~2.2-fold increase in the proportion of time females and males, respectively, used torpor in comparison to that in the pre-fire and control groups. Overall, likely due to reproductive needs, torpor was more pronounced in females than in males, but low ambient temperatures increased torpor bout duration in both sexes. Importantly, for both male and female antechinus and likely other small mammals, predator avoidance and energy conservation - achieved by reduced activity and increased torpor use - appear to be vital for post-fire survival where ground cover and refuges have been obliterated. Copyright © 2016 Elsevier Inc. All rights reserved.
Sathre, Roger; Masanet, Eric
2012-09-04
To understand the long-term energy and climate implications of different implementation strategies for carbon capture and storage (CCS) in the US coal-fired electricity fleet, we integrate three analytical elements: scenario projection of energy supply systems, temporally explicit life cycle modeling, and time-dependent calculation of radiative forcing. Assuming continued large-scale use of coal for electricity generation, we find that aggressive implementation of CCS could reduce cumulative greenhouse gas emissions (CO(2), CH(4), and N(2)O) from the US coal-fired power fleet through 2100 by 37-58%. Cumulative radiative forcing through 2100 would be reduced by only 24-46%, due to the front-loaded time profile of the emissions and the long atmospheric residence time of CO(2). The efficiency of energy conversion and carbon capture technologies strongly affects the amount of primary energy used but has little effect on greenhouse gas emissions or radiative forcing. Delaying implementation of CCS deployment significantly increases long-term radiative forcing. This study highlights the time-dynamic nature of potential climate benefits and energy costs of different CCS deployment pathways and identifies opportunities and constraints of successful CCS implementation.
Children's Knowledge of Fire Safety. Stage 2. The Final Report for the New Zealand Fire Service.
ERIC Educational Resources Information Center
Dunn, Karyn; Renwick, Margery
In 1991 the New Zealand Fire Service planned a primary school fire-safety education program for children from new entrants to form 2. The program introduces a new module to the children each year of their primary education. This study was undertaken in an attempt to measure the effectiveness of the program. A sample of 1,089 children completed…
Avifaunal responses to fire in southwestern montane forests along a burn severity gradient
Natasha B. Kotliar; Patricia L. Kennedy; Kimberly Ferree
2007-01-01
The effects of burn severity on avian communities are poorly understood, yet this information is crucial to fire management programs. To quantify avian response patterns along a burn severity gradient, we sampled 49 random plots (2001-2002) at the 17351-ha Cerro Grande Fire (2000) in New Mexico, USA. Additionally, pre-fire avian surveys (1986- 1988, 1990) created a...
Fuel and fire behavior in high-elevation five-needle pines affected by mountain pine beetle
Michael J. Jenkins
2011-01-01
Bark beetle-caused tree mortality in conifer forests affects the quantity and quality of forest fuels and has long been assumed to increase fire hazard and potential fire behavior. In reality, bark beetles and their effects on fuel accumulation and subsequent fire hazard have only recently been described. We have extensively sampled fuels in three conifer forest types...
Characterization of biomass burning aerosols from forest fire in Indonesia
NASA Astrophysics Data System (ADS)
Fujii, Y.; Iriana, W.; Okumura, M.; Lestari, P.; Tohno, S.; Akira, M.; Okuda, T.
2012-12-01
Biomass burning (forest fire, wild fire) is a major source of pollutants, generating an estimate of 104 Tg per year of aerosol particles worldwide. These particles have adverse human health effects and can affect the radiation budget and climate directly and indirectly. Eighty percent of biomass burning aerosols are generated in the tropics and about thirty percent of them originate in the tropical regions of Asia (Andreae, 1991). Several recent studies have reported on the organic compositions of biomass burning aerosols in the tropical regions of South America and Africa, however, there is little data about forest fire aerosols in the tropical regions of Asia. It is important to characterize biomass burning aerosols in the tropical regions of Asia because the aerosol properties vary between fires depending on type and moisture of wood, combustion phase, wind conditions, and several other variables (Reid et al., 2005). We have characterized PM2.5 fractions of biomass burning aerosols emitted from forest fire in Indonesia. During the dry season in 2012, PM2.5 aerosols from several forest fires occurring in Riau, Sumatra, Indonesia were collected on quartz and teflon filters with two mini-volume samplers. Background aerosols in forest were sampled during transition period of rainy season to dry season (baseline period). Samples were analyzed with several analytical instruments. The carbonaceous content (organic and elemental carbon, OC and EC) of the aerosols was analyzed by a thermal optical reflectance technique using IMPROVE protocol. The metal, inorganic ion and organic components of the aerosols were analyzed by X-ray Fluorescence (XRF), ion chromatography and gas chromatography-mass spectrometry, respectively. There was a great difference of chemical composition between forest fire and non-forest fire samples. Smoke aerosols for forest fires events were composed of ~ 45 % OC and ~ 2.5 % EC. On the other hand, background aerosols for baseline periods were composed of ~ 18 % OC and ~ 10 % EC. OC/EC ratio was consistently lower (~ 2) for baseline periods than that for forest fire events (~ 20). OC and EC concentrations for forest fire events were more than 150 times and 10 times higher than those for baseline periods.
Propellant Residues Deposition from Firing of AT4 Rockets
2009-12-01
and 254 nm (cell path 1 cm), and a Finnigan SpectraSYSTEM AS300 autosampler. Samples were introduced with a 100-μL sample loop . Separations were...analytical laboratory. The remaining particle samples were left in sealed jars and stored on site in a refrigerator, and the snow sample was stored in a...Ranney. 1998. Characterization of antitank firing ranges at CFB Valcartier. WATC Wainwright, and CFAD Dundurn. DREV-R-9809. Val- Bélair, QC: DRDC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tom Elicson; Bentley Harwood; Jim Bouchard
Over a 12 month period, a fire PRA was developed for a DOE facility using the NUREG/CR-6850 EPRI/NRC fire PRA methodology. The fire PRA modeling included calculation of fire severity factors (SFs) and fire non-suppression probabilities (PNS) for each safe shutdown (SSD) component considered in the fire PRA model. The SFs were developed by performing detailed fire modeling through a combination of CFAST fire zone model calculations and Latin Hypercube Sampling (LHS). Component damage times and automatic fire suppression system actuation times calculated in the CFAST LHS analyses were then input to a time-dependent model of fire non-suppression probability. Themore » fire non-suppression probability model is based on the modeling approach outlined in NUREG/CR-6850 and is supplemented with plant specific data. This paper presents the methodology used in the DOE facility fire PRA for modeling fire-induced SSD component failures and includes discussions of modeling techniques for: • Development of time-dependent fire heat release rate profiles (required as input to CFAST), • Calculation of fire severity factors based on CFAST detailed fire modeling, and • Calculation of fire non-suppression probabilities.« less
Four channel Laser Firing Unit using laser diodes
NASA Technical Reports Server (NTRS)
Rosner, David, Sr.; Spomer, Edwin, Sr.
1994-01-01
This paper describes the accomplishments and status of PS/EDD's (Pacific Scientific/Energy Dynamics Division) internal research and development effort to prototype and demonstrate a practical four channel laser firing unit (LFU) that uses laser diodes to initiate pyrotechnic events. The LFU individually initiates four ordnance devices using the energy from four diode lasers carried over the fiber optics. The LFU demonstrates end-to-end optical built in test (BIT) capabilities. Both Single Fiber Reflective BIT and Dual Fiber Reflective BIT approaches are discussed and reflection loss data is presented. This paper includes detailed discussions of the advantages and disadvantages of both BIT approaches, all-fire and no-fire levels, and BIT detection levels. The following topics are also addressed: electronic control and BIT circuits, fiber optic sizing and distribution, and an electromechanical shutter type safe/arm device. This paper shows the viability of laser diode initiation systems and single fiber BIT for typing military applications.
Emissions impacts of wind and energy storage in a market environment.
Sioshansi, Ramteen
2011-12-15
This study examines the emissions impacts of adding wind and energy storage to a market-based electric power system. Using Texas as a case study, we demonstrate that market power can greatly effect the emissions benefits of wind, due to most of the coal-fired generation being owned by the two dominant firms. Wind tends to have less emissions benefits when generators exercise market power, since coal-fired generation is withheld from the market and wind displaces natural gas-fired generators. We also show that storage can have greater negative emissions impacts in the presence of wind than if only storage is added to the system. This is due to wind increasing on- and off-peak electricity price differences, which increases the amount that storage and coal-fired generation are used. We demonstrate that this effect is exacerbated by market power.
Modelling Variable Fire Severity in Boreal Forests: Effects of Fire Intensity and Stand Structure
Miquelajauregui, Yosune; Cumming, Steven G.; Gauthier, Sylvie
2016-01-01
It is becoming clear that fires in boreal forests are not uniformly stand-replacing. On the contrary, marked variation in fire severity, measured as tree mortality, has been found both within and among individual fires. It is important to understand the conditions under which this variation can arise. We integrated forest sample plot data, tree allometries and historical forest fire records within a diameter class-structured model of 1.0 ha patches of mono-specific black spruce and jack pine stands in northern Québec, Canada. The model accounts for crown fire initiation and vertical spread into the canopy. It uses empirical relations between fire intensity, scorch height, the percent of crown scorched and tree mortality to simulate fire severity, specifically the percent reduction in patch basal area due to fire-caused mortality. A random forest and a regression tree analysis of a large random sample of simulated fires were used to test for an effect of fireline intensity, stand structure, species composition and pyrogeographic regions on resultant severity. Severity increased with intensity and was lower for jack pine stands. The proportion of simulated fires that burned at high severity (e.g. >75% reduction in patch basal area) was 0.80 for black spruce and 0.11 for jack pine. We identified thresholds in intensity below which there was a marked sensitivity of simulated fire severity to stand structure, and to interactions between intensity and structure. We found no evidence for a residual effect of pyrogeographic region on simulated severity, after the effects of stand structure and species composition were accounted for. The model presented here was able to produce variation in fire severity under a range of fire intensity conditions. This suggests that variation in stand structure is one of the factors causing the observed variation in boreal fire severity. PMID:26919456
Modelling Variable Fire Severity in Boreal Forests: Effects of Fire Intensity and Stand Structure.
Miquelajauregui, Yosune; Cumming, Steven G; Gauthier, Sylvie
2016-01-01
It is becoming clear that fires in boreal forests are not uniformly stand-replacing. On the contrary, marked variation in fire severity, measured as tree mortality, has been found both within and among individual fires. It is important to understand the conditions under which this variation can arise. We integrated forest sample plot data, tree allometries and historical forest fire records within a diameter class-structured model of 1.0 ha patches of mono-specific black spruce and jack pine stands in northern Québec, Canada. The model accounts for crown fire initiation and vertical spread into the canopy. It uses empirical relations between fire intensity, scorch height, the percent of crown scorched and tree mortality to simulate fire severity, specifically the percent reduction in patch basal area due to fire-caused mortality. A random forest and a regression tree analysis of a large random sample of simulated fires were used to test for an effect of fireline intensity, stand structure, species composition and pyrogeographic regions on resultant severity. Severity increased with intensity and was lower for jack pine stands. The proportion of simulated fires that burned at high severity (e.g. >75% reduction in patch basal area) was 0.80 for black spruce and 0.11 for jack pine. We identified thresholds in intensity below which there was a marked sensitivity of simulated fire severity to stand structure, and to interactions between intensity and structure. We found no evidence for a residual effect of pyrogeographic region on simulated severity, after the effects of stand structure and species composition were accounted for. The model presented here was able to produce variation in fire severity under a range of fire intensity conditions. This suggests that variation in stand structure is one of the factors causing the observed variation in boreal fire severity.
Firefighter noise exposure during training activities and general equipment use.
Root, Kyle S; Schwennker, Catherine; Autenrieth, Daniel; Sandfort, Delvin R; Lipsey, Tiffany; Brazile, William J
2013-01-01
Multiple noise measurements were taken on 6 types of fire station equipment and 15 types of emergency response vehicle-related equipment used by firefighters during routine and emergency operations at 10 fire stations. Five of the six types of fire station equipment, when measured at a distance of one meter and ear level, emitted noise equal to or greater than 85 dBA, including lawn maintenance equipment, snow blowers, compressors, and emergency alarms. Thirteen of 15 types of equipment located on the fire engines emitted noise levels equal to or greater than 85 dBA, including fans, saws, alarms, and extrication equipment. In addition, noise measurements were taken during fire engine operations, including the idling vehicle, vehicle sirens, and water pumps. Results indicated that idling fire-engine noise levels were below 85 dBA; however, during water pump and siren use, noise levels exceeded 85 dBA, in some instances, at different locations around the trucks where firefighters would be stationed during emergency operations. To determine if the duration and use of fire fighting equipment was sufficient to result in overexposures to noise during routine training activities, 93 firefighter personal noise dosimetry samples were taken during 10 firefighter training activities. Two training activities per sampling day were monitored during each sampling event, for a mean exposure time of 70 min per day. The noise dosimetry samples were grouped based on job description to compare noise exposures between the different categories of job tasks commonly associated with fire fighting. The three job categories were interior, exterior, and engineering. Mean personal dosimetry results indicated that the average noise exposure was 78 dBA during the training activities that lasted 70 min on average. There was no significant difference in noise exposure between each of the three job categories. Although firefighters routinely use equipment and emergency response vehicles that can produce hazardous levels of noise, this study showed that the average noise levels experienced by firefighters was below generally accepted guidelines.
NASA Astrophysics Data System (ADS)
Lombao, Alba; Barreiro, Ana; Martín, Ángela; Díaz-Raviña, Montserrat
2015-04-01
Microorganisms play an important role in forest ecosystems, especially after fire when vegetation is destroyed and soil is bared. Fire severity and recurrence might be one of main factors controlling the microbial response after a wildfire but information about this topic is scarce. The aim of this study is to evaluate the influence of fire regimen (recurrence and severity) on soil microbial community structure by means of the analysis of phospholipid fatty acid (PLFA). The study was performed with unburned and burned samples collected from the top layer of a soil affected by a high severity fire (Laza, NW Spain) heated under laboratory conditions at different temperatures (50°C, 75°C, 100°C, 125°C, 150°C, 175°C, 200°C, 300°C) to simulate different fire intensities; the process was repeated after further soil recovery (1 month incubation) to simulate fire recurrence. The soil temperature was measured with thermocouples and used to calculate the degree-hours as estimation of the amount of heat supplied to the samples (fire severity). The PLFA analysis was used to estimate total biomass and the biomass of specific groups (bacteria, fungi, gram-positive bacteria and gram-negative bacteria) as well as microbial community structure (PLFA pattern) and PLFA data were analyzed by means of principal component analysis (PCA) in order to identify main factors determining microbial community structure. The results of PCA, performed with the whole PLFA data set, showed that first component explained 35% of variation and clearly allow us to differentiate unburned samples from the corresponding burned samples, while the second component, explaining 16% of variation, separated samples according the heating temperature. A marked impact of fire regimen on soil microorganisms was detected; the microbial community response varied depending on previous history of soil heating and the magnitude of changes in the PLFA pattern was related to the amount of heat supplied to the samples. Thus, wildfire was the main factor determining the microbial community structure followed, in less extent, by fire severity. The total biomass and the biomass of specifics microbial groups decreased notably as consequence of wildfire and minor changes were detected due to soil heating under laboratory conditions. The results clearly showed the usefulness of PLFA pattern combined with PCA to study the relationships between fire regimen (recurrence and severity) and associated direct and indirect changes in soil microorganisms. The data also indicated that degree-hours methodology rather than temperature is adequate for evaluating the impact of soil heating on microbial communities. Keywords: wildfire, heating temperature, degree-hours, PLFA pattern, microbial biomass Acknowledgements. This study was supported by the Ministerio Español de Economía y Competitividad (AGL2012-39688-C02-01). A Lombao is recipient of FPU grant from Ministerio Español de Educación.
GLOVEBOX WINDOWS, FIRE PROTECTION AND VOICES FROM THE PAST
DOE Office of Scientific and Technical Information (OSTI.GOV)
Till, W
2009-04-15
'Study the past--what is past is prologue'. These words appear as the motto on a pair of statues at the National Archives Building in Washington DC. They are also the opening sentence in the preface of a document written in August of 1956 entitled 'A Summary of Accidents and Incidents Involving Radiation in Atomic Energy Activities--June 1945 thru December 1955'. This document, one of several written by D.F. Hayes of the Safety and Fire Protection Branch, Division of Organization and Personnel, U.S. Atomic Energy Commission in Washington DC, and many others are often forgotten even though they contain valuable gloveboxmore » fire protection lessons for us today.« less
Forest fuels on organic and associated soils in the Coastal Plain of North Carolina
G. W. Wendel; T. G Storey; G. M. Byram
1962-01-01
The fire problem in the organic soil (pocosin) areas of eastern North Carolina centers a round the frequent and costly blowup wildfires occurring there and the use of fire as a management tool. Under certain combinations of fuel and weather, low intensity fires will suddenly and often unexpectedly multiply their rate of energy output many times . In almost all...
Unmanned Vehicle Material Flammability Test
NASA Technical Reports Server (NTRS)
Urban, David; Ruff, Gary A.; Fernandez-Pello, A. Carlos; T’ien, James S.; Torero, Jose L.; Cowlard, Adam; Rouvreau, Sebastian; Minster, Olivier; Toth, Balazs; Legros, Guillaume;
2013-01-01
Microgravity combustion phenomena have been an active area of research for the past 3 decades however, there have been very few experiments directly studying spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample and environment sizes typical of those expected in a spacecraft fire. All previous experiments have been limited to samples of the order of 10 cm in length and width or smaller. Terrestrial fire safety standards for all other habitable volumes on earth, e.g. mines, buildings, airplanes, ships, etc., are based upon testing conducted with full-scale fires. Given the large differences between fire behavior in normal and reduced gravity, this lack of an experimental data base at relevant length scales forces spacecraft designers to base their designs using 1-g understanding. To address this question a large scale spacecraft fire experiment has been proposed by an international team of investigators. This poster presents the objectives, status and concept of this collaborative international project to examine spacecraft material flammability at realistic scales. The concept behind this project is to utilize an unmanned spacecraft such as Orbital Cygnus vehicle after it has completed its delivery of cargo to the ISS and it has begun its return journey to earth. This experiment will consist of a flame spread test involving a meter scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. A computer modeling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the examination of fire behavior on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This will be the first opportunity to examine microgravity flame behavior at scales approximating a spacecraft fire.
Canedo-Júnior, Ernesto de Oliveira; Cuissi, Rafael Gonçalves; Nelson Henrique de Almeida, Curi; Demetrio, Guilherme Ramos; Lasmar, Chaim José; Malves, Kira
2016-03-01
Fire occurrences are a common perturbation in Cerrado ecosystems, and may differently impact the local biodiversity. Arthropods are one of the taxa affected by fires, and among them, ants are known as good bioindicators. We aimed to evaluate the effect of anthropic fires on epigaeic and hypogaeic ant communities (species richness and composition) in Cerrado areas with different post-fire event recovery periods. We conducted the study in four Cerrado areas during two weeks of 2012 dry season: one unburned and three at different post-fire times (one month, one and two years). We sampled ants with pitfall traps in epigaeic and hypogaeic microhabitats. We collected 71 ant morpho-species from 25 genera. In the epigaeic microhabitat we sampled 56 morpho-species and 42 in the hypogaeic microhabitat. The area with the shortest recovery time presented lower epigaeic ant species richness (4.3 ± 2.00) in comparison to the other areas (8.1 ± 2.68 species on one year area; 10.3 ± 2.66 species on two years area; 10.4 ± 2.31 species on control area), but recovery time did not affect hypogaeic ant species richness. Regarding ant species composition, fire did not directly affect hypogaeic ant species, which remained the same even one month after fire event. However, two years were not enough to reestablish ant species composition in both microhabitats in relation to our control group samples. Our study is the first to assess anthropic fire effects upon epigaeic and hypogaeic ants communities; highlighting the importance of evaluating different microhabitats, to more accurately detect the effects of anthropic disturbances in biological communities. We concluded that ant communities are just partially affected by fire occurrences, and epigaeic assemblages are the most affected ones in comparison to hypogaeic ants. Furthermore the study provides knowledge to aid in the creation of vegetation management programs that allow Cerrado conservation.
Development of fire test methods for airplane interior materials
NASA Technical Reports Server (NTRS)
Tustin, E. A.
1978-01-01
Fire tests were conducted in a 737 airplane fuselage at NASA-JSC to characterize jet fuel fires in open steel pans (simulating post-crash fire sources and a ruptured airplane fuselage) and to characterize fires in some common combustibles (simulating in-flight fire sources). Design post-crash and in-flight fire source selections were based on these data. Large panels of airplane interior materials were exposed to closely-controlled large scale heating simulations of the two design fire sources in a Boeing fire test facility utilizing a surplused 707 fuselage section. Small samples of the same airplane materials were tested by several laboratory fire test methods. Large scale and laboratory scale data were examined for correlative factors. Published data for dangerous hazard levels in a fire environment were used as the basis for developing a method to select the most desirable material where trade-offs in heat, smoke and gaseous toxicant evolution must be considered.
Integrating remote sensing and terrain data in forest fire modeling
NASA Astrophysics Data System (ADS)
Medler, Michael Johns
Forest fire policies are changing. Managers now face conflicting imperatives to re-establish pre-suppression fire regimes, while simultaneously preventing resource destruction. They must, therefore, understand the spatial patterns of fires. Geographers can facilitate this understanding by developing new techniques for mapping fire behavior. This dissertation develops such techniques for mapping recent fires and using these maps to calibrate models of potential fire hazards. In so doing, it features techniques that strive to address the inherent complexity of modeling the combinations of variables found in most ecological systems. Image processing techniques were used to stratify the elements of terrain, slope, elevation, and aspect. These stratification images were used to assure sample placement considered the role of terrain in fire behavior. Examination of multiple stratification images indicated samples were placed representatively across a controlled range of scales. The incorporation of terrain data also improved preliminary fire hazard classification accuracy by 40%, compared with remotely sensed data alone. A Kauth-Thomas transformation (KT) of pre-fire and post-fire Thematic Mapper (TM) remotely sensed data produced brightness, greenness, and wetness images. Image subtraction indicated fire induced change in brightness, greenness, and wetness. Field data guided a fuzzy classification of these change images. Because fuzzy classification can characterize a continuum of a phenomena where discrete classification may produce artificial borders, fuzzy classification was found to offer a range of fire severity information unavailable with discrete classification. These mapped fire patterns were used to calibrate a model of fire hazards for the entire mountain range. Pre-fire TM, and a digital elevation model produced a set of co-registered images. Training statistics were developed from 30 polygons associated with the previously mapped fire severity. Fuzzy classifications of potential burn patterns were produced from these images. Observed field data values were displayed over the hazard imagery to indicate the effectiveness of the model. Areas that burned without suppression during maximum fire severity are predicted best. Areas with widely spaced trees and grassy understory appear to be misrepresented, perhaps as a consequence of inaccuracies in the initial fire mapping.
Fuel models and fire potential from satellite and surface observations
Burgan, R.E.; Klaver, R.W.; Klarer, J.M.
1998-01-01
A national 1-km resolution fire danger fuel model map was derived through use of previously mapped land cover classes and ecoregions, and extensive ground sample data, then refined through review by fire managers familiar with various portions of the U.S. The fuel model map will be used in the next generation fire danger rating system for the U.S., but it also made possible immediate development of a satellite and ground based fire potential index map. The inputs and algorithm of the fire potential index are presented, along with a case study of the correlation between the fire potential index and fire occurrence in California and Nevada. Application of the fire potential index in the Mediterranean ecosystems of Spain, Chile, and Mexico will be tested.
Hower, J.C.; Robertson, J.D.; Wong, A.S.; Eble, C.F.; Ruppert, L.F.
1997-01-01
The Middle Pennsylvanian Breathitt Formation (Westphalian B) Pond Creek and Fire Clay coal beds are the 2 largest producing coal beds in eastern Kentucky. Single channel samples from 22 localities in the Pond Creek coal bed were obtained from active coal mines in Pike and Martin Countries, Kentucky, and a total of 18 Fire Clay coal bed channel samples were collected from localities in the central portion of the coal field. The overall objective of this study was to investigate the concentration and distribution of potentially hazardous elements in the Fire Clay and Pond Creek coal beds, with particular emphasis on As and Pb, 2 elements that are included in the 1990 Clean Air Act Amendments as potential air toxics. The 2 coals are discussed individually as the depositional histories are distinct, the Fire Clay coal bed having more sites where relatively high-S lithologies are encountered. In an effort to characterize these coals, 40 whole channel samples, excluding 1-cm partings, were analyzed for major, minor and trace elements by X-ray fluorescence and proton-induced X-ray emission spectroscopy. Previously analyzed samples were added to provide additional geographic coverage and lithotype samples from one site were analyzed in order to provide detail of vertical elemental trends. The As and Pb levels in the Fire Clay coal bed tend to be higher than in the Pond Creek coal bed. One whole channel sample of the Fire Clay coal bed contains 1156 ppm As (ash basis), with a single lithotype containing 4000 ppm As (ash basis). Most of the As and Pb appears to be associated with pyrite, which potentially can be removed in beneficiation (particularly coarser pyrite). Disseminated finer pyrite may not be completely removable by cleaning. In the examination of pyrite conducted in this study, it does not appear that significant concentration of As or Pb occurs in the finer pyrite forms. The biggest potential problem of As- or Pb-enriched pyrite is, therefore, one of refuse disposal.
The high energy demand of neuronal cells caused by passive leak currents is not a waste of energy.
Berndt, Nikolaus; Holzhütter, Hermann-Georg
2013-11-01
It is estimated that maintenance of the resting potential of neurons consumes between 15% (in gray matter) and 44% (in fully myelinated white matter) of the brain's total energy budget [1]. This poses the intriguing question why evolution has not strived to lower the permeability of passive ion channels to cut the high resting-state energy budget of the brain. Based on a conceptual mathematical model of neuronal ion currents and action potential (AP) firing we demonstrate that a neuron endowed with small leak currents and correspondingly low energy consumption by the Na(+)/K(+)-ATPase in the resting state may indeed recapitulate all features of normal AP firing. However, the activation and inactivation of such a "low-energy-cost neuron" turns out to be extremely sensitive to small fluctuation of Na(+) currents associated with Na(+)-dependent secondary-active transport that is indispensable for the metabolic integrity of the cell and neurotransmitter recycling. We provide evidence that sufficiently large leak currents function as important stabilizers of the membrane potential and thus are required to allow robust AP firing. Our simulations suggest that the energy demand of the Na(+)/K(+)-ATPase needed to counterbalance passive leak currents cannot be significantly dropped below observed values.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, M.; Mohapatra, P.; Patel, S.K.
2009-07-01
In the present investigation, fired pellets were made by mixing hematite iron ore fines of -100, -16+18, and -8+10 mesh size in different ratios and studies on their reduction kinetics in Lakhanpur, Orient OC-2 and Belpahar coals were carried out at temperatures ranging from 850{sup o}C to 1000{sup o}C with a view toward promoting the massive utilization of fines in ironmaking. The rate of reduction in all the fired iron ore pellets increased markedly with an increase in temperature up to 1000{sup o}C, and it was more intense in the first 30min. The values of activation energy, calculated from integralmore » and differential approaches, for the reduction of fired pellets (prepared from iron ore fines of -100 mesh size) in coals were found to be in the range 131-148 and 130-181 kJ mol{sup -1} (for =0.2 to 0.8), indicating the process is controlled by a carbon gasification reaction. The addition of selected larger size particles in the matrix of -100 mesh size fines up to the extent studied decreased the activation energy and slightly increased the reduction rates of resultant fired pellets. In comparison to coal, the reduction of fired pellets in char was characterized by significantly lower reduction rates and higher activation energy.« less
Pereira, P.; beda, X.; Martin, D.; Mataix-Solera, J.; Guerrero, C.
2011-01-01
Wildfire is the major disturbance in Mediterranean forests. Prescribed fire can be an alternative to reduce the amount of fuel and hence decrease the wildfire risk. However the effects of prescribed fire must be studied, especially on ash properties, because ash is an important nutrient source for ecosystem recovery. The aim of this study is to determine the effects of a low severity prescribed fire on water-soluble elements in ash including pH, electrical conductivity (EC), calcium (Ca), magnesium (Mg), sodium (Na), potassium (K), aluminum (Al), manganese (Mn), iron (Fe), zinc (Zn), silica (SiO2) and total sulphur (TS). A prescribed fire was conducted in a cork oak (Quercus suber) (Q.S) forest located in the northeast part of the Iberian Peninsula. Samples were collected from a flat plot of 40??70m mainly composed of Q.S and Quercus robur (Q.R) trees. In order to understand the effects of the prescribed fire on the soluble elements in ash, we conducted our data analysis on three data groups: all samples, only Q.S samples and only Q.R samples. All three sample groups exhibited a significant increase in pH, EC (p<0.001), water-soluble Ca, Mg, Na, SiO2 and TS and a decrease in water-soluble Mn, Fe and Zn. Differences were identified between oak species for water-soluble K, Al and Fe. In Q.S samples we registered a significant increase in the first two elements p<0.001 and p<0.01, respectively, and a non-significant impact in the third, at p<0.05. In Q.R data we identified a non-significant impact on water-soluble K and Al and a significant decrease in water-soluble Fe (p<0.05). These differences are probably due to vegetation characteristics and burn severity. The fire induced a higher variability in the ash soluble elements, especially in Q.S samples, that at some points burned with higher severity. The increase of pH, EC, Ca, Mg, Na and K will improve soil fertility, mainly in the study area where soils are acidic. The application of this low severity prescribed fire will improve soil nutrient status without causing soil degradation and thus is considered to be a good management strategy. ?? 2010 Elsevier Inc.
Pereira, Paulo; Ubeda, Xavier; Martin, Deborah; Mataix-Solera, Jorge; Guerrero, César
2011-02-01
Wildfire is the major disturbance in Mediterranean forests. Prescribed fire can be an alternative to reduce the amount of fuel and hence decrease the wildfire risk. However the effects of prescribed fire must be studied, especially on ash properties, because ash is an important nutrient source for ecosystem recovery. The aim of this study is to determine the effects of a low severity prescribed fire on water-soluble elements in ash including pH, electrical conductivity (EC), calcium (Ca), magnesium (Mg), sodium (Na), potassium (K), aluminum (Al), manganese (Mn), iron (Fe), zinc (Zn), silica (SiO(2)) and total sulphur (TS). A prescribed fire was conducted in a cork oak (Quercus suber) (Q.S) forest located in the northeast part of the Iberian Peninsula. Samples were collected from a flat plot of 40×70m mainly composed of Q.S and Quercus robur (Q.R) trees. In order to understand the effects of the prescribed fire on the soluble elements in ash, we conducted our data analysis on three data groups: all samples, only Q.S samples and only Q.R samples. All three sample groups exhibited a significant increase in pH, EC (p<0.001), water-soluble Ca, Mg, Na, SiO(2) and TS and a decrease in water-soluble Mn, Fe and Zn. Differences were identified between oak species for water-soluble K, Al and Fe. In Q.S samples we registered a significant increase in the first two elements p<0.001 and p<0.01, respectively, and a non-significant impact in the third, at p<0.05. In Q.R data we identified a non-significant impact on water-soluble K and Al and a significant decrease in water-soluble Fe (p<0.05). These differences are probably due to vegetation characteristics and burn severity. The fire induced a higher variability in the ash soluble elements, especially in Q.S samples, that at some points burned with higher severity. The increase of pH, EC, Ca, Mg, Na and K will improve soil fertility, mainly in the study area where soils are acidic. The application of this low severity prescribed fire will improve soil nutrient status without causing soil degradation and thus is considered to be a good management strategy. Copyright © 2010 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
Computer generated data on the performance of the cogeneration energy conversion system are presented. Performance parameters included fuel consumption and savings, capital costs, economics, and emissions of residual fired process boilers.
NASA Astrophysics Data System (ADS)
Xie, Xinglong; Xue, Weixian
2018-02-01
The aim of this paper is to examine energy consumption among poverty-stricken loess areas of middle Gansu, and put forward a settlement to energy upgrading and meanwhile mitigating environmental contagion and shaking off poverty. Energy consumption of 371 households from 3 distinctive categories of landform is explored. The surveyed data investigation displays that energy consumption composition is marked by clear dissimilarity of power mix, with stalk(41%) and coal(32.3%) acting as the major form, fire grass a powerful supplement, and the remaining power resources playing a tiny part for the mountain; coal(52.45%) being the dominant power, dry grasses(20%) and stalk (17.6%) performing a supplemental part, other resources of power being at the insignificant position for the semi-mountain; beside which there being a similar energy pattern on the plain except stalk composing a tiny share of 7.5%. This energy mix is mainly attributed to economic poverty, and provokes a list of ills such as plant damage, water loss and soil erosion, ultimately posing a formidable threat to sustainable development. A fresh energy engineering mode termed quaternity-dominating pattern is introduced and addressed, which can lift the sample areas out of poverty both in economics and energy. The paper concludes with pointing out practical proposals on launching and running this energy engineering project for the sample areas. This paper contributes to the growing body of knowledge by exploring energy use among poverty-stricken regions, usually being disregarded in most studies of China.
NASA Technical Reports Server (NTRS)
Johnson, H. T.; Linley, L. J.; Mansfield, J. A.
1982-01-01
A series of large-scale JP-4 fuel pool fire tests was conducted to refine existing mathematical models of large fires. Seven tests were conducted to make chemical concentration and temperature measurements in 7.5 and 15 meter-diameter pool fires. Measurements were made at heights of 0.7, 1.4, 2.9, 5.7, 11.4, and 21.3 meters above the fires. Temperatures were measured at up to 50 locations each second during the fires. Chemistry samples were taken at up to 23 locations within the fires and analyzed for combustion chemistry and soot concentration. Temperature and combustion chemistry profiles obtained during two 7.5 meter-diameter and two 15 meter-diameter fires are included.
Final Report to the Department of Energy Renewable Energy and Energy Efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaughen, Shasta
The Pala Band of Mission Indians was awarded a DOE-EERE Solar Energy Grant for FY 2016 and 2017. The project involved installing a 94.8 kW DC photovoltaic (PC) solar system on the Pala Fire Station to offset up to 95% of grid-derived energy and reduce overall CO 2 generation from the facility. Pala successfully installed rooftop and carport-mounted solar panels at the fire station, and to date has generated of 219,227 kWh of energy and offset 274,034 pounds of CO 2. The project was successfully executed, and we recommend other tribes to undertake similar projects if they are located inmore » areas with sufficient solar exposure. DOE should continue to make these funds available to tribes.« less
Fires can benefit plants by disrupting antagonistic interactions.
García, Y; Castellanos, M C; Pausas, J G
2016-12-01
Fire has a key role in the ecology and evolution of many ecosystems, yet its effects on plant-insect interactions are poorly understood. Because interacting species are likely to respond to fire differently, disruptions of the interactions are expected. We hypothesized that plants that regenerate after fire can benefit through the disruption of their antagonistic interactions. We expected stronger effects on interactions with specialist predators than with generalists. We studied two interactions between two Mediterranean plants (Ulex parviflorus, Asphodelus ramosus) and their specialist seed predators after large wildfires. In A. ramosus we also studied the generalist herbivores. We sampled the interactions in burned and adjacent unburned areas during 2 years by estimating seed predation, number of herbivores and fruit set. To assess the effect of the distance to unburned vegetation we sampled plots at two distance classes from the fire perimeter. Even 3 years after the fires, Ulex plants experienced lower seed damage by specialists in burned sites. The presence of herbivores on Asphodelus decreased in burned locations, and the variability in their presence was significantly related to fruit set. Generalist herbivores were unaffected. We show that plants can benefit from fire through the disruption of their antagonistic interactions with specialist seed predators for at least a few years. In environments with a long fire history, this effect might be one additional mechanism underlying the success of fire-adapted plants.
Ryan W. McEwan; Todd F. Hutchinson; Robert P. Long; Robert D. Ford; Brian C. McCarthy
2007-01-01
What was the role of fire during the establishment of the current overstory (ca. 1870-1940) in mixed-oak forests of eastern North America? Nine sites representing a 240-km latitudinal gradient on the Allegheny and Cumberland Plateaus of eastern North America. Basal cross-sections were collected from 225 trees. Samples were surfaced, and fire scars were dated. Fire...
Influence of fire and El Niño on tree recruitment by Sierran mixed conifer
Malcolm North; Matthew Hurteau; Robert Fiegener; Michael Barbour
2005-01-01
The influence of fire and climate events on age structure of different species was examined in old-growth mixed conifer in the southern Sierra Nevada. Within a 48-ha stem-mapped sample area, after a mechanical thinning, all stumps were examined for fire scars and 526 stumps were cut to ground level and aged. Before 1865, which was the last widespread fire event, the...
Holocene disturbance dynamics from a pine-dominated forest in central British Columbia, Canada
NASA Astrophysics Data System (ADS)
Brown, K. J.; Hebda, N.; Condor, N.; Hebda, R.; Hawkes, B.
2013-12-01
A lake sediment record was retrieved from the Sub-Boreal Pine-Spruce biogeoclimatic zone on the Chilcotin Plateau in central British Columbia, Canada. The record is being analyzed for charcoal, pollen, and magnetic susceptibility, as well as insect and mollusc content. The oldest radiocarbon age is 9.2 cal BP, illustrating that the record spans most of the Holocene. Regarding fire disturbance, charcoal fragments are persistent throughout the core, revealing that fire disturbance has characterized the site for millennia. In total, 74 fire events were recognized. During the warm dry early Holocene, fire frequency was 12-15 fires 2000 yr-1 and peak magnitudes were low, possibly in response to a more open landscape. A change in fire regime occurred at ca. 5000 cal BP, as fire frequency increased, peaking at ca. 20 fires 2000 yr-1 by 3000 cal BP. Peak magnitude likewise increased notably, possibly in response to the development of denser forest cover. On-going analysis of pollen will better constrain the vegetation history in this poorly sampled region. In contrast to charcoal, which was pervasive, Dendroctonus ponderosae (mountain pine beetle) remains were absent in both modern and paleo samples. Given that several insect outbreaks have occurred in the region in the last 100 years, the scarcity of remains is likely related to taphonomic issues.
Numerical simulation study on the distribution law of smoke flow velocity in horizontal tunnel fire
NASA Astrophysics Data System (ADS)
Liu, Yejiao; Tian, Zhichao; Xue, Junhua; Wang, Wencai
2018-02-01
According to the fluid similarity theory, the simulation experiment system of mining tunnel fire is established. The grid division of experimental model roadway is carried on by GAMBIT software. By setting the boundary and initial conditions of smoke flow during fire period in FLUENT software, using RNG k-Ɛ two-equation turbulence model, energy equation and SIMPLE algorithm, the steady state numerical simulation of smoke flow velocity in mining tunnel is done to obtain the distribution law of smoke flow velocity in tunnel during fire period.
Revisiting the Long-Term Hedge Value of Wind Power in an Era of Low Natural Gas Prices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolinger, Mark
Expanding production of the United States’ vast shale gas reserves in recent years has put the country on a path towards greater energy independence, enhanced economic prosperity, and (potentially) reduced emissions of greenhouse gases and other pollutants. The corresponding expansion of gas-fired generation in the power sector – driven primarily by lower natural gas prices – has also made it easier and cheaper to integrate large amounts of variable renewable generation, such as wind power, into the grid. At the same time, however, low natural gas prices have suppressed wholesale power prices across the nation, making it harder for windmore » and other renewable power technologies to compete on cost alone – even despite their recent cost and performance improvements. A near-term softening in policy-driven demand from state-level renewable energy mandates, coupled with a possible phase-out of a key federal tax incentive over time, may exacerbate wind’s challenge in the coming years. As wind power finds it more difficult to compete with gas-fired generation on the basis of near-term cost, it will increasingly need to rely on other attributes, such as its “portfolio” or “hedge” value, as justification for inclusion in the power mix. This article investigates the degree to which wind power can still serve as a cost-effective hedge against rising natural gas prices, given the significant reduction in gas prices in recent years, coupled with expectations that prices will remain low for many years to come. It does so by drawing upon a rich sample of long-term power purchase agreements (“PPAs”) between existing wind generators and electric utilities in the U.S., and comparing the contracted prices at which utilities will be buying wind power from these existing projects for decades to come to a variety of long-term projections of the fuel costs of gas-fired generation modeled by the Energy Information Administration (“EIA”).« less
Fire regime in a Mexican forest under indigenous resource management.
Fulé, Peter Z; Ramos-Gómez, Mauro; Cortés-Montaño, Citlali; Miller, Andrew M
2011-04-01
The Rarámuri (Tarahumara) people live in the mountains and canyons of the Sierra Madre Occidental of Chihuahua, Mexico. They base their subsistence on multiple-use strategies of their natural resources, including agriculture, pastoralism, and harvesting of native plants and wildlife. Pino Gordo is a Rarámuri settlement in a remote location where the forest has not been commercially logged. We reconstructed the forest fire regime from fire-scarred trees, measured the structure of the never-logged forest, and interviewed community members about fire use. Fire occurrence was consistent throughout the 19th and 20th centuries up to our fire scar collection in 2004. This is the least interrupted surface-fire regime reported to date in North America. Studies from other relict sites such as nature reserves in Mexico or the USA have all shown some recent alterations associated with industrialized society. At Pino Gordo, fires recurred frequently at the three study sites, with a composite mean fire interval of 1.9 years (all fires) to 7.6 years (fires scarring 25% or more of samples). Per-sample fire intervals averaged 10-14 years at the three sites. Approximately two-thirds of fires burned in the season of cambial dormancy, probably during the pre-monsoonal drought. Forests were dominated by pines and contained many large living trees and snags, in contrast to two nearby similar forests that have been logged. Community residents reported using fire for many purposes, consistent with previous literature on fire use by indigenous people. Pino Gordo is a valuable example of a continuing frequent-fire regime in a never-harvested forest. The Rarámuri people have actively conserved this forest through their traditional livelihood and management techniques, as opposed to logging the forest, and have also facilitated the fire regime by burning. The data contribute to a better understanding of the interactions of humans who live in pine forests and the fire regimes of these ecosystems, a topic that has been controversial and difficult to assess from historical or paleoecological evidence.
NASA Astrophysics Data System (ADS)
Tapper, N.; Beringer, J.; Hutley, L.; Coutts, A.
2003-04-01
Fire is probably the greatest natural and anthropogenic environmental disturbance in Australia's tropical savannas, with the vast area burned each year (up to 250,000 km^2) likely to increase with predicted regional climate change. Globally savanna ecosystems cover 11.5% of the global landscape (Scholes and Hall 1996). As much as 75% of this landscape burns annually (Hao et al., 1990), accounting for more than 40% of all global biomass consumed (Hao and Ward 1993). These landscape-scale fires undoubtedly have massive impacts on regional water, energy and carbon dioxide exchanges and as a result may have important feedbacks to the atmosphere and regional climate. Fire may influence climate directly through the emission of smoke and trace gases from burning, but there are other important impacts of fire that may affect the atmosphere. Fire and the subsequent fire scars are likely to radically alter the surface energy budgets of tropical savannas through reduced surface albedo, increased available energy for partitioning into the convective fluxes, and increased substrate heat flux. The aerodynamic and biological properties of the ecosystem may also change, affecting surface-atmosphere coupling. There is a clear potential to influence atmospheric motion and moist convection at a range of scales. Potential fire scar impacts such as those mentioned above have previously been largely ignored and are the focus of the Savanna Fire Experiment (SAFE). Tower measurements of radiation, heat, moisture and CO_2 fluxes above burned and unburned savanna near Darwin, Australia, were initiated in August 2001 to observe the impacts of fire and fire scarring on flux exchange with the atmosphere, along with the longer term post-fire recovery of fluxes. Intensive field campaigns were mounted in the dry (fire) seasons of both 2001 and 2002, with flux recovery observed into the each of the subsequent monsoon seasons. Results and an early analysis of the time series of heat and moisture flux data are presented in this paper and the wider implications of the work are discussed. Hao, W. M., and D. E. Ward. 1993. Methane production from global biomass burning. Journal of Geophysical Research 98: 20657-61. Hao, W. M., M.-H. Liu, and P. J. Crutzen. 1990. Estimates of annual and regional releases of CO2, and other trace gases to the atmosphere from fires in the tropics, based on FAO statistics for the period 1975--1980. In. Fire in the Tropical Biota, Ecological Studies 84. Ed. J. G. Goldammer, 440--462. New York: Springer-Verlag. Scholes, R.J. and D.O. Hall 1996. The carbon budget of tropical savannas, woodlands and grasslands. In Global Change: Effects on Coniferous Forests and Gransslands. Ed. A.I. Breymeyer, D.O. Hall, J.M. Melillo and G.I. Ågren John Wiley and Sons, New York.
2016-10-28
constraints and wire routing issues. • Outside sites have more space, but require outdoor rated equipment (NEMA outdoor rated.. ) and more maintenance...sustainable power, in many different types, sizes and capacities, as follows: • Cogen Plant #1 B1579: 7.2MW gas-fired turbine at Substation “AA...Cogen Plant #2 B1991: (2) 4.6MW gas-fired turbines at “Gillespie” Substation • 300kW fuel cell at Substation “AA” • PPA: 1.015MW solar photovoltaic
The State-of-the-Art of Materials Technology Used for Fossil and Nuclear Power Plants in China
NASA Astrophysics Data System (ADS)
Weng, Yuqing
Combined with the development of energy in China during the past 30 years, this paper clarified that high steam parameters ultra-supercritical (USC) coal-fired power plants and 1000MW nuclear power plants are the most important method to optimize energy structure and achieve national goals of energy saving and CO2 emission in China. Additionally, requirement of materials technology in high steam parameters USC coal-fired power plants and 1000MW nuclear power plants, current research and major development of relevant materials technology in China were briefly described in this paper.
NASA Astrophysics Data System (ADS)
French, N. H. F.; Ottmar, R. D.; Brown, T. J.; Larkin, N. K.
2017-12-01
The Fire and Smoke Model Evaluation Experiment (FASMEE) is an integrative research effort to identify and collect critical measurements to improve operational wildland fire and smoke prediction systems. FASMEE has two active phases and one suggested phase. Phase 1 is the analysis and planning process to assess the current state of fire-plume-smoke modeling and to determine the critical measurements required to evaluate and improve these operational fire and smoke models. As the major deliverable for Phase 1, a study plan has been completed that describes the measurement needs, field campaigns, and command, safety and air space de-confliction plans necessary to complete the FASMEE project. Phase 2 is a set of field campaigns to collect data during 2019-2022. Future Improvements would be a set of analyses and model improvements based on the data collected within Phase 2 that is dependent on identifying future funding sources. In this presentation, we will review the FASMEE Study Plan and detailed measurements and conditions expected for the four to five proposed research burns. The recommended measurements during Phase 2 span the four interrelated disciplines of FASMEE: fuels and consumption, fire behavior and energy, plume dynamics and meteorology, and smoke emissions, chemistry, and transport. Fuel type, condition, and consumption during wildland fire relates to several fire impacts including radiative heating, which provides the energy that drives fire dynamics. Local-scale meteorology is an important factor which relates to atmospheric chemistry, dispersion, and transport. Plume dynamics provide the connection between fire behavior and far-field smoke dispersion, because it determines the vertical distribution of the emissions. Guided by the data needs and science questions generated during Phase 1, three wildland fire campaigns were selected. These included the western wildfire campaign (rapid deployment aimed at western wildfires supporting NOAA, NASA, and NSF smoke flights), southwestern campaign (targeting high intensity prescribed fires), and southeastern campaign (targeting large and higher than average fuel loadings with important smoke management relevancy).
Modeling and Analysis of Realistic Fire Scenarios in Spacecraft
NASA Technical Reports Server (NTRS)
Brooker, J. E.; Dietrich, D. L.; Gokoglu, S. A.; Urban, D. L.; Ruff, G. A.
2015-01-01
An accidental fire inside a spacecraft is an unlikely, but very real emergency situation that can easily have dire consequences. While much has been learned over the past 25+ years of dedicated research on flame behavior in microgravity, a quantitative understanding of the initiation, spread, detection and extinguishment of a realistic fire aboard a spacecraft is lacking. Virtually all combustion experiments in microgravity have been small-scale, by necessity (hardware limitations in ground-based facilities and safety concerns in space-based facilities). Large-scale, realistic fire experiments are unlikely for the foreseeable future (unlike in terrestrial situations). Therefore, NASA will have to rely on scale modeling, extrapolation of small-scale experiments and detailed numerical modeling to provide the data necessary for vehicle and safety system design. This paper presents the results of parallel efforts to better model the initiation, spread, detection and extinguishment of fires aboard spacecraft. The first is a detailed numerical model using the freely available Fire Dynamics Simulator (FDS). FDS is a CFD code that numerically solves a large eddy simulation form of the Navier-Stokes equations. FDS provides a detailed treatment of the smoke and energy transport from a fire. The simulations provide a wealth of information, but are computationally intensive and not suitable for parametric studies where the detailed treatment of the mass and energy transport are unnecessary. The second path extends a model previously documented at ICES meetings that attempted to predict maximum survivable fires aboard space-craft. This one-dimensional model implies the heat and mass transfer as well as toxic species production from a fire. These simplifications result in a code that is faster and more suitable for parametric studies (having already been used to help in the hatch design of the Multi-Purpose Crew Vehicle, MPCV).
NASA Astrophysics Data System (ADS)
Howard, R. G.
The active solar energy system for a recreation hall for senior citizens in Wisconsin, is equipped with 1290 square feet of evacuated tube collectors, 3000 gallons of water in a tank, and a natural gas fired furnace for auxiliary space heating and a natural gas fired domestic water heater. The solar fraction, solar savings ratio, conventional fuel savings, system performance factor, and solar system coefficient of performance are given as well as performance data for the collector, storage, domestic hot water, and space heating subsystems, operating energy, energy savings, and weather conditions. Predicted performance data are also given for comparison with the measured data.
Uncertainties of wild-land fires emission in AQMEII phase 2 case study
NASA Astrophysics Data System (ADS)
Soares, J.; Sofiev, M.; Hakkarainen, J.
2015-08-01
The paper discusses the main uncertainties of wild-land fire emission estimates used in the AQMEII-II case study. The wild-land fire emission of particulate matter for the summer fire season of 2010 in Eurasia was generated by the Integrated System for wild-land Fires (IS4FIRES). The emission calculation procedure included two steps: bottom-up emission compilation from radiative energy of individual fires observed by MODIS instrument on-board of Terra and Aqua satellites; and top-down calibration of emission factors based on the comparison between observations and modelled results. The approach inherits various uncertainties originating from imperfect information on fires, inaccuracies of the inverse problem solution, and simplifications in the fire description. These are analysed in regard to the Eurasian fires in 2010. It is concluded that the total emission is likely to be over-estimated by up to 50% with individual-fire emission accuracy likely to vary in a wide range. The first results of the new IS4FIRESv2 products and fire-resolving modelling are discussed in application to the 2010 events. It is shown that the new emission estimates have similar patterns but are lower than the IS4FIRESv1 values.
Level I Energy and Water Survey, ERDC-CERL, Champaign, IL
2015-05-12
heating will allow for better capacity distribution, optimized boiler fire rates, and the flexibility of moving to possibly more efficient methods in the...by 108 hrs/week. The heat transfer coefficient of the areas served by the FCUs was calculat- ed to estimate the energy savings by operating the HVAC...configuration is not op- timal and should be retrofitted. F&S recommended removing one of the 1968 Cleaver Brooks fire -tube boilers and replacing it with two
NASA Astrophysics Data System (ADS)
Chang, Chun-Hung; Fried, Nathaniel M.
2016-02-01
Infrared lasers have been used in combination with applied cooling methods to preserve superficial skin layers during cosmetic surgery. Similarly, combined laser irradiation and tissue cooling may also allow development of minimally invasive laser therapies beyond dermatology. This study compares diffusing, side-firing, and radial delivery laser balloon catheter designs for creation of subsurface lesions in tissue, ex vivo, using a near-IR laser and applied contact cooling. An Ytterbium fiber laser with 1075 nm wavelength delivered energy through custom built 18 Fr (6-mm-OD) balloon catheters incorporating either 10-mm-long diffusing fiber tip, 90 degree side-firing fiber, or radial delivery cone mirror, through a central lumen. A chilled solution was flowed through a separate lumen into 9-mm-diameter balloon to keep probe cooled at 7°C. Porcine liver tissue samples were used as preliminary tissue model for immediate observation of thermal lesion creation. The diffusing fiber produced subsurface thermal lesions measuring 49.3 +/- 10.0 mm2 and preserved 0.8 +/- 0.1 mm of surface tissue. The side-firing fiber produced subsurface thermal lesions of 2.4 +/- 0.9 mm2 diameter and preserved 0.5 +/- 0.1 mm of surface tissue. The radial delivery probe assembly failed to produce subsurface thermal lesions, presumably due to the small effective spot diameter at the tissue surface, which limited optical penetration depth. Optimal laser power and irradiation time measured 15 W and 100 s for diffusing fiber and 1.4 W and 20 s, for side-firing fiber, respectively. Diffusing and side-firing laser balloon catheter designs provided subsurface thermal lesions in tissue. However, the divergent laser beam in both designs limited the ability to preserve a thicker layer of tissue surface. Further optimization of laser and cooling parameters may be necessary to preserve thicker surface tissue layers.
NASA Astrophysics Data System (ADS)
Miesel, J. R.; Reiner, A. L.; Ewell, C. M.; Sanderman, J.; Maestrini, B.; Adkins, J.
2016-12-01
Widespread US fire suppression policy has contributed to an accumulation of vegetation in many western forests relative to historic conditions, and these changes can exacerbate wildfire severity and carbon (C) emissions. Serious concern exists about positive feedbacks between wildfire emissions and global climate; however, fires not only release C from terrestrial to atmospheric pools, they also create "black" or pyrogenic C (PyC) which contributes to longer-term C stability. Our objective was to quantify wildfire impacts on aboveground and belowground total C and PyC stocks in California mixed-conifer forests. We worked with incident management teams to access five active wildfires to establish and measure plots within days before and after fire. We measured pre- and post-fire aboveground forest structure and woody fuels to calculate aboveground biomass, biomass C, and PyC, and we collected pre- and post-fire forest floor and 0-5 cm mineral soil samples to measure belowground C and PyC stocks. Our preliminary results show that fire had minimal impact on the number of trees per hectare, whereas C losses from the tree layer occurred via consumption of foliage, and PyC gain occurred in tree bark. Fire released 54% to 100% of surface fuel C. In the forest floor layer, we observed 33 to 100% C loss, whereas changes in PyC stocks ranged from 100% loss to 186% gain relative to pre-fire samples. In general, fire had minimal to no impact on 0-5 cm mineral soil C. We will present relationships between total C, PyC and post-fire C and N dynamics in one of the five wildfire sites. Our data are unique because they represent nearly immediate pre- and post-fire measurements in major wildfires in a widespread western U.S. forest type. This research advances understanding of the role of fire on forest C fluxes and C sequestration potential as PyC.
NASA Astrophysics Data System (ADS)
Hyer, Edward J.; Reid, Jeffrey S.; Prins, Elaine M.; Hoffman, Jay P.; Schmidt, Christopher C.; Miettinen, Jukka I.; Giglio, Louis
2013-03-01
Biomass burning patterns over the Maritime Continent of Southeast Asia are examined using a new active fire detection product based on application of the Wildfire Automated Biomass Burning Algorithm (WF_ABBA) to data from the imagers on the MTSAT geostationary satellites operated by the Japanese space agency JAXA. Data from MTSAT-1R and MTSAT-2 covering 34 months from September 2008 to July 2011 are examined for a study region consisting of Indonesia, Malaysia, and nearby environs. The spatial and temporal distributions of fires detected in the MTSAT WF_ABBA product are described and compared with active fire observations from MODIS MOD14 data. Land cover distributions for the two instruments are examined using a new 250 m land cover product from the National University of Singapore. The two products show broadly similar patterns of fire activity, land cover distribution of fires, and pixel fire radiative power (FRP). However, the MTSAT WF_ABBA data differ from MOD14 in important ways. Relative to MODIS, the MTSAT WF_ABBA product has lower overall detection efficiency, but more fires detected due to more frequent looks, a greater relative fraction of fires in forest and a lower relative fraction of fires in open areas, and significantly higher single-pixel retrieved FRP. The differences in land cover distribution and FRP between the MTSAT and MODIS products are shown to be qualitatively consistent with expectations based on pixel size and diurnal sampling. The MTSAT WF_ABBA data are used to calculate coverage-corrected diurnal cycles of fire for different regions within the study area. These diurnal cycles are preliminary but demonstrate that the fraction of diurnal fire activity sampled by the two MODIS sensors varies significantly by region and vegetation type. Based on the results from comparison of the two fire products, a series of steps is outlined to account for some of the systematic biases in each of these satellite products in order to produce a successful merged fire detection product.
Issues in the analyze of low content gold mining samples by fire assay technique
NASA Astrophysics Data System (ADS)
Cetean, Valentina
2016-04-01
The classic technique analyze of samples with low gold content - below 0.1 g/t (=100 ppb = parts per billion), either ore or gold sediments, involves the preparation of sample by fire assay extraction, followed by the chemical attack with aqua regia (hydrochloric and nitric acid) and measuring the gold content by atomic absorption spectrometry or inductively coupled mass spectrometry. The issues raised by this analysis are well known for the world laboratories, commercial or research ones. The author's knowledge regarding this method of determining the gold content, accumulated in such laboratory from Romania (with more than 40 years of experience, even if not longer available from 2014) confirms the obtaining of reliable results required a lot of attention, amount of work and the involving of an experienced fire assayer specialist. The analytical conclusion for a research laboratory is that most reliable and statistically valid results are till reached for samples with more than 100 ppb gold content; the degree of confidence below this value is lower than 90%. Usually, for samples below 50 ppb, it does not exceed 50-70 %, unless without very strictly control of each stage, that involve additional percentage of hours allocated for successive extracting tests and knowing more precisely the other compounds that appear in the sample (Cu, Sb, As, sulfur / sulphides, Te, organic matter, etc.) or impurities. The most important operation is the preparation, namely: - grinding and splitting of sample (which can cause uneven distribution of gold flakes in the double samples for analyzed); - pyro-metallurgical recovery of gold = fire assay stage, involving the more precise temperature control in furnace during all stages (fusion and cupellation) and adjusting of the fire assay flux components to produce a successful fusion depending of the sample matrix and content; - reducing the sample weight to decrease the amount of impurities that can be concentrated in the lead button during oxidation stage. The better metal recovery and the decreasing of the amount of errors for low gold content samples are controlled in this case by: - the management of the quantity of one or more components of the flux, depending on the chemical composition of the sample (sometimes just by observing the behavior and the visual characteristics of lead Au + Ag button/bead and the resulted slag); - addition of gold-free silver, which will be removed by chemical reduction with aqua regia after the fire assay stage. Regarding the instrumental analyze stage of the samples with less than 100 ppb gold content, there were obtained similar values by both techniques: atomic absorption and inductively coupled mass spectrometry, taking into account each of them has different detection limit. It is mandatory the quality control with a certified reference material with known content, both in the fire assay stage and the reading instrumental stage. This abstract are written in the frame of the SUSMIN project: "Tools for sustainable gold mining in EU".
Postfire shrub-cover dynamics: a 70-year fire history in big sagebrush communities.
USDA-ARS?s Scientific Manuscript database
Land managers use prescribed fire to meet rangeland management objectives. This study was conducted to quantify, from present conditions, the effect of time since last burn (TSLB) on shrub cover over 70 yr of fire history. We sampled mountain big sagebrush communities at the USDA, ARS, U.S. Sheep ...
Fire prevention in the California Division of Forestry. . .personnel and practices
Adam Sarapata; William S. Folkman
1970-01-01
A sample of California Division of Forestry employees whose jobs include some contact with the public were queried about job satisfaction and employee motivations, and their responses were related to the Division's fire prevention program. Most respondents felt that Division management considered the program less important than fire suppression and detection. They...
Fire intensity impacts on post-fire temperate coniferous forest net primary productivity
NASA Astrophysics Data System (ADS)
Sparks, Aaron M.; Kolden, Crystal A.; Smith, Alistair M. S.; Boschetti, Luigi; Johnson, Daniel M.; Cochrane, Mark A.
2018-02-01
Fire is a dynamic ecological process in forests and impacts the carbon (C) cycle through direct combustion emissions, tree mortality, and by impairing the ability of surviving trees to sequester carbon. While studies on young trees have demonstrated that fire intensity is a determinant of post-fire net primary productivity, wildland fires on landscape to regional scales have largely been assumed to either cause tree mortality, or conversely, cause no physiological impact, ignoring the impacted but surviving trees. Our objective was to understand how fire intensity affects post-fire net primary productivity in conifer-dominated forested ecosystems on the spatial scale of large wildland fires. We examined the relationships between fire radiative power (FRP), its temporal integral (fire radiative energy - FRE), and net primary productivity (NPP) using 16 years of data from the MOderate Resolution Imaging Spectrometer (MODIS) for 15 large fires in western United States coniferous forests. The greatest NPP post-fire loss occurred 1 year post-fire and ranged from -67 to -312 g C m-2 yr-1 (-13 to -54 %) across all fires. Forests dominated by fire-resistant species (species that typically survive low-intensity fires) experienced the lowest relative NPP reductions compared to forests with less resistant species. Post-fire NPP in forests that were dominated by fire-susceptible species were not as sensitive to FRP or FRE, indicating that NPP in these forests may be reduced to similar levels regardless of fire intensity. Conversely, post-fire NPP in forests dominated by fire-resistant and mixed species decreased with increasing FRP or FRE. In some cases, this dose-response relationship persisted for more than a decade post-fire, highlighting a legacy effect of fire intensity on post-fire C dynamics in these forests.
Assessing Live Fuel Moisture For Fire Management Applications
David R. Weise; Roberta A. Hartford; Larry Mahaffey
1998-01-01
The variation associated with sampling live fuel moisture was examined for several shrub and canopy fuels in southern California, Arizona, and Colorado. Ninety-five % confidence intervals ranged from 5 to % . Estimated sample sizes varied greatly. The value of knowing the live fuel moisture content in fire decision making is unknown. If the fuel moisture is highly...
NASA Technical Reports Server (NTRS)
Rice, Eric E.; St. Clair, Christopher P.; Chiaverini, Martin J.; Knuth, William H.; Gustafson, Robert J.; Gramer, Daniel J.
1999-01-01
ORBITEC is developing methods for producing, testing, and utilizing Mars-based ISRU fuel/oxidizer combinations to support low cost, planetary surface and flight propulsion and power systems. When humans explore Mars we will need to use in situ resources that are available, such as: energy (solar); gases or liquids for life support, ground transportation, and flight to and from other surface locations and Earth; and materials for shielding and building habitats and infrastructure. Probably the easiest use of Martian resources to reduce the cost of human exploration activities is the use of the carbon and oxygen readily available from the CO2 in the Mars atmosphere. ORBITEC has conducted preliminary R&D that will eventually allow us to reliably use these resources. ORBITEC is focusing on the innovative use of solid CO as a fuel. A new advanced cryogenic hybrid rocket propulsion system is suggested that will offer advantages over LCO/LOX propulsion, making it the best option for a Mars sample return vehicle and other flight vehicles. This technology could also greatly support logistics and base operations by providing a reliable and simple way to store solar or nuclear generated energy in the form of chemical energy that can be used for ground transportation (rovers/land vehicles) and planetary surface power generators. This paper describes the overall concept and the test results of the first ever solid carbon monoxide/oxygen rocket engine firing.
Myatt, Theodore A; Vincent, Michael S; Kobzik, Lester; Naeher, Luke P; MacIntosh, David L; Suh, Helen
2011-10-01
To assess the effect of fine particulate matter (PM(2.5)) from different particle sources on tumor necrosis factor- (TNF-) α, we measured TNF production from rat alveolar macrophages (AM) and human dendritic cells (DC) exposed to PM(2.5) from different sources. Fire-related PM(2.5) samples, rural ambient, and urban indoor and outdoor samples were collected in the Southeast United States. Tumor necrosis factor release was measured from rat AM and human DC following incubation with PM(2.5). Tumor necrosis factor release in AMs was greatest for fire-related PM(2.5) compared with other samples (TNF: P value = 0.005; mortality: P value = 0.005). Tumor necrosis factor releases from the DCs and AMs exposed to fire-associated PM(2.5) were strongly correlated (r = 0.87, P value < 0.0001). Particulate matter exposure produces TNF release consistent with pulmonary inflammation in rat AMs and human DCs, with the response in rat AMs differing by particle source.
AmeriFlux US-An2 Anaktuvuk River Moderate Burn
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hobbie, John; Rocha, Adrian; Shaver, Gaius
This is the AmeriFlux version of the carbon flux data for the site US-An2 Anaktuvuk River Moderate Burn. Site Description - The Anaktuvuk River fire on the North Slope of Alaska started on July 16, 2007 by lightning. It continued until the end of September when nearby lakes had already frozen over and burned >256,000 acres, creating a mosaic of patches that differed in burn severity. The Anaktuvuk River Severe Burn, Moderate Burn, and Unburned sites are 40 km to the west of the nearest road and were selected in late May 2008 to determine the effects of the firemore » on carbon, water, and energy exchanges during the growing season. Because the fire had burned through September of the previous year, initial deployment of flux towers occurred prior to any significant vegetative regrowth, and our sampling campaign captured the full growing season in 2008. The Moderate Burn site consisted of a large area with small patches of completely and partially burned tundra intermixed across the landscape.« less
NASA Astrophysics Data System (ADS)
Wen, Wangxi; Li, Chunchun; Sun, Yihua; Tang, Ying; Fang, Liang
2018-02-01
An ultralow-firing microwave dielectric ceramic Cu3Mo2O9 with orthorhombic structure has been fabricated via a solid-state reaction method. X-ray diffraction analysis, Rietveld refinement, Raman spectroscopy, energy-dispersive spectrometry, and scanning electron microscopy were employed to explore the phase purity, crystal structure, and microstructure. Pure and dense Cu3Mo2O9 ceramics could be obtained in the sintering temperature range from 580°C to 680°C. The sample sintered at 660°C for 4 h exhibited the highest relative density (˜ 97.2%) and best microwave dielectric properties with ɛ r = 7.2, Q × f = 19,300 GHz, and τ f = - 7.8 ppm/°C. Chemical compatibility with aluminum electrodes was also confirmed. All the results suggest that Cu3Mo2O9 ceramic is a promising candidate for use in ultralow-temperature cofired ceramic applications.
Detection and analysis of high-temperature events in the BIRD mission
NASA Astrophysics Data System (ADS)
Zhukov, Boris; Briess, Klaus; Lorenz, Eckehard; Oertel, Dieter; Skrbek, Wolfgang
2005-01-01
The primary mission objective of a new small Bi-spectral InfraRed Detection (BIRD) satellite is detection and quantitative analysis of high-temperature events like fires and volcanoes. An absence of saturation in the BIRD infrared channels makes it possible to improve false alarm rejection as well as to retrieve quantitative characteristics of hot targets, including their effective fire temperature, area and the radiative energy release. Examples are given of detection and analysis of wild and coal seam fires, of volcanic activity as well as of oil fires in Iraq. The smallest fires detected by BIRD, which were verified on ground, had an area of 12m2 at daytime and 4m2 at night.
Impact of a low intensity controlled-fire in some chemical soil properties.
NASA Astrophysics Data System (ADS)
Martínez-Murillo, Juan F.; Hueso-González, Paloma; Aranda-Gómez, Francisco; Damián Ruiz-Sinoga, José
2014-05-01
Some changes in chemical soil properties can be observed after fires of low intensities. pH and electric conductivity tend to increase, while C/N ratio decrease. In the case of organic matter, the content can increase due to the massive incorporation of necromass including, especially, plants and roots. The aim of this study is to assess the impact of low intensity and controlled fire in some soil properties in field conditions. El Pinarillo experimental area is located in South of Spain. Two set of closed plots were installed (24 m2: 12 m length x 2 m width). One of them was remained as control with the original vegetation cover (Mediterranean matorral: Rosmarinus officinalis, Cistus clusii, Lavandula stoechas, Chamaeropos humilis, Thymus baetica), and the other one was burnt in a controlled-fire in 2011. Weather conditions and water content of vegetation influenced in the intensity of fire (low). After the controlled-fire, soil surface sample (0-5 cm) were taken in both set of plots (B, burnt soil samples; C, control soil samples). Some soil chemical properties were analysed: organic matter content (OM), C/N ratio, pH and electrical conductivity (EC). Some changes were observed in B corroborating a controlled-fire of low intensity. pH remained equal after fire (B: pH=7.7±0.11; C: pH=7.7±0.04). An increment was obtained in the case of EC (B: EC=0.45 mScm-1±0.08 mScm-1; C: EC=0.35 mScm-1±0.07 mScm-1) and OM (B: OM=8.7%±3.8%; C: pH=7.3%±1.5%). Finally, C/N ratio decreased after fire respect to the control and initial conditions (B: C/N=39.0±14.6; C: C/N =46.5±10.2).
Reassessment of the use of fire as a management tool in deciduous forests of eastern North America.
Matlack, Glenn R
2013-10-01
Prescribed burning is increasingly being used in the deciduous forests of eastern North America. Recent work suggests that historical fire frequency has been overestimated east of the prairie-woodland transition zone, and its introduction could potentially reduce forest herb and shrub diversity. Fire-history recreations derived from sedimentary charcoal, tree fire scars, and estimates of Native American burning suggest point-return times ranging from 5-10 years to centuries and millennia. Actual return times were probably longer because such records suffer from selective sampling, small sample sizes, and a probable publication bias toward frequent fire. Archeological evidence shows the environmental effect of fire could be severe in the immediate neighborhood of a Native American village. Population density appears to have been low through most of the Holocene, however, and villages were strongly clustered at a regional scale. Thus, it appears that the majority of forests of the eastern United States were little affected by burning before European settlement. Use of prescribed burning assumes that most forest species are tolerant of fire and that burning will have only a minimal effect on diversity. However, common adaptations such as serotiny, epicormic sprouting, resprouting from rhizomes, and smoke-cued germination are unknown across most of the deciduous region. Experimental studies of burning show vegetation responses similar to other forms of disturbance that remove stems and litter and do not necessarily imply adaptation to fire. The general lack of adaptation could potentially cause a reduction in diversity if burning were introduced. These observations suggest a need for a fine-grained examination of fire history with systematic sampling in which all subregions, landscape positions, and community types are represented. Responses to burning need to be examined in noncommercial and nonwoody species in rigorous manipulative experiments. Until such information is available, it seems prudent to limit the use of prescribed burning east of the prairie-woodland transition zone. © 2013 Society for Conservation Biology.
Castillo, Miguel E; Molina, Juan R; Rodríguez Y Silva, Francisco; García-Chevesich, Pablo; Garfias, Roberto
2017-02-01
Wildfires constitute the greatest economic disruption to Mediterranean ecosystems, from a socio-economic and ecological perspective (Molina et al., 2014). This study proposes to classify fire intensity levels based on potential fire behavior in different types of Mediterranean vegetation types, using two geographical scales. The study considered >4 thousand wildfires over a period of 25years, identifying fire behavior on each event, based on simulations using "KITRAL", a model developed in Chile in 1993 and currently used in the entire country. Fire intensity values allowed results to be classified into six fire effects categories (levels), each of them with field indicators linking energy values with damage related to burned vegetation and wildland urban interface zone. These indicators also facilitated a preliminary assessment of wildfire impact on different Mediterranean land uses and, are therefore, a useful tool to prioritize future interventions. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Stocks, B. J.; Fromm, M. D.; Servranckx, R.; Lindsey, D.
2007-12-01
The recent confirmation that smoke from high-intensity boreal forest fires can reach the Upper Troposphere/Lower Stratosphere (UTLS) through pyroconvection and be transported long distances has raised concern over the wider-scale environmental impact of boreal fire smoke. This concern is further elevated as climate change projections indicate a significant increase in the frequency and severity of boreal forest fires over the next century. Smoke in the UTLS is frequently transported to the Arctic and may have important implications for the radiative energy budget in the polar region. Soot deposition from fires may lead to enhanced melting of sea ice and glaciers, and the chemical impact of fire emissions at high altitudes is largely unknown. This knowledge gap will be addressed during the International Polar Year (IPY), as boreal fire emissions will be tracked and documented in detail through aerial, satellite and ground-based measurements, as a key component of the POLARCAT (Polar Study using Aircraft, Remote Sensing, Surface Measurements and Models, of Climate, Chemistry, Aerosols, and Transport) and ARCTAS (Arctic Research of the Composition of the Troposphere from Aircraft and Satellites) projects to be conducted in 2008. A large fire in the Canadian Northwest Territories burned throughout the month of June 2007, in a remote region where forest fires are not actively suppressed, eventually reaching 90,000 hectares in size. This fire was monitored for blowup one week in advance; it erupted into pyroconvection on June 25, 2007. We present an analysis of this event combining satellite data with ground-based measurements to document the development and impact of this classic pyroCb event. Under extreme fire danger conditions, the fire burned close to 20,000 hectares on that day. Fire behavior was consistent with predictions using the Canadian Fire Behavior Prediction System, with the fire spreading at 2.7 km/hr, consuming 33,000 kg of fuel hourly, generating an energy release rate of ~45,000 kW/m. This constitutes a typical high-intensity boreal crown fire, common across northern Canada every summer, and often capable of producing independent pyroconvection. The June 25 blowup was monitored using OMI AI, CALIPSO, Aqua MODIS, AVHRR and GOES satellite imagery, and these measurements validated the predicted fire behavior, including the development of a convection column that rose 10-11 km and injected smoke within the UTLS. Over subsequent days this smoke spread to Arctic latitudes (70-80 degrees N).
Measurements of nitrous oxide emissions from P.F. fired power stations
NASA Astrophysics Data System (ADS)
Sloan, S. A.; Laird, C. K.
Nitrous oxide (N 2O) was measured in the flue gas from four wall-fired and three corner-fired 500 MW boilers, fitted with either conventional or low-NO x burners, at four C.E.G.B. power stations. Measurements were made both by on-line non-dispersive infra red (NDIR) monitors and by extractive sampling for later laboratory analysis by electron capture gas chromatography (ECD GC). It was found that the on-line and laboratory methods were in good agreement for samples analyzed within 1-3 h of sampling, but that the nitrous oxide concentration in the stored samples had a tendency to increase with time, which was dependent on the concentration of water in the sample. Experiments with synthetic mixtures showed that the increase in nitrous oxide concentration was consistent with the overall reaction2NO+SO 2→N 2O+SO 3 in which nitric oxide is reduced by sulphur dioxide. The highest average N 2O concentration measured by the on-line analyzer was 16 vpm, and for most of the boilers monitored the concentration was less than 10 vpm. There was no statistically significant difference between the measured N 2O emissions from normal boilers and those fitted with low-NO x burners. It is suggested that these values are close to the true levels of N 2O emissions from p.f. fired boilers and that recent reports of high levels (up to 200 vpm) are likely to be an artefact resulting from the observed generation of N 2O in stored samples. A consequence of these measurements of N 2O is that current estimates of the contribution of emissions from p.f. fired boilers to the global N 2O budget are likely to be too high.
Radtke, Robert P; Stokes, Robert H; Glowka, David A
2014-12-02
A method for operating an impulsive type seismic energy source in a firing sequence having at least two actuations for each seismic impulse to be generated by the source. The actuations have a time delay between them related to a selected energy frequency peak of the source output. One example of the method is used for generating seismic signals in a wellbore and includes discharging electric current through a spark gap disposed in the wellbore in at least one firing sequence. The sequence includes at least two actuations of the spark gap separated by an amount of time selected to cause acoustic energy resulting from the actuations to have peak amplitude at a selected frequency.
Moritz, Max A; Odion, Dennis C
2005-06-01
Fire can be a dominant process in the ecology of forest vegetation and can also affect forest disease dynamics. Little is known about the relationship between fire and an emerging disease epidemic called Sudden Oak Death, which is caused by a new pathogen, Phytophthora ramorum. This disease has spread across a large, fire-prone portion of California, killing great numbers of oaks and tanoaks and infecting most associated woody plants. Suitable hosts cover a much broader geographic range, raising concern over where the disease may spread. To understand the strength and potential sensitivities of a fire-disease relationship, we examined geographic patterns of confirmed P. ramorum infections in relation to past fire history. We found these infections to be extremely rare within the perimeter of any area burned since 1950. This finding is not caused by spatial bias in sampling for the disease, and is robust to variation in host abundance scenarios and to aggregation of closely spaced sampling locations. We therefore investigated known fire-related factors that could result in significantly lower incidence of the disease in relatively recently burned landscapes. Chemical trends in post-fire environments can influence the success of pathogens like P. ramorum, either by increasing plant nutrient stress or by reducing the occurrence of chemicals antagonistic to Phytophthoras. Succession in the absence of fire leads to greater abundance of host species, which will provide increased habitat for P. ramorum; this will also increase intraspecific competition where these trees are abundant, and other density-dependent effects (e.g. shading) can reduce resource allocation to defenses. Despite these findings about a fire-disease relationship, a much deeper understanding is necessary before fire can be actively used as a tool in slowing the epidemic.
Garrison Project - Lake Sakakawea Oil and Gas Management Plan, North Dakota
2012-11-01
When the air gun is fired , pulses of acoustic energy are produced causing the shock waves needed for data collection (Peterson, 2004). • Seismic...The proposed casing program shall include the size, weight, grade, and length of casing proposed, type of thread and coupling, and setting depth of...suppression of fires on public lands caused by its employees, contractors or subcontractors. During conditions of extreme fire danger, surface use
Science in 60 â Simulating Flames Helps Tame Future Wildfires
Lin, Rod
2018-01-16
FIRETEC presents a new way of studying fire and learning how to better manage and cope with it. The model provides additional scientific input for decisions by policymakers working in land management, water resources and energy. The team hopes it will eventually assist fire and fuel management operations. This research is done in partnership with the USDA Forest Service, Air Force Wildland Fire Center, INRA and Canadian Forest Service.
Gravett, M R; Hopkins, F B; Self, A J; Webb, A J; Timperley, C M; Riches, J R
2014-08-01
In the event of alleged use of organophosphorus nerve agents, all kinds of environmental samples can be received for analysis. These might include decontaminated and charred matter collected from the site of a suspected chemical attack. In other scenarios, such matter might be sampled to confirm the site of a chemical weapon test or clandestine laboratory decontaminated and burned to prevent discovery. To provide an analytical capability for these contingencies, we present a preliminary investigation of the effect of accelerant-based fire and liquid decontamination on soil contaminated with the nerve agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). The objectives were (a) to determine if VX or its degradation products were detectable in soil after an accelerant-based fire promoted by aviation fuel, including following decontamination with Decontamination Solution 2 (DS2) or aqueous sodium hypochlorite, (b) to develop analytical methods to support forensic analysis of accelerant-soaked, decontaminated and charred soil and (c) to inform the design of future experiments of this type to improve analytical fidelity. Our results show for the first time that modern analytical techniques can be used to identify residual VX and its degradation products in contaminated soil after an accelerant-based fire and after chemical decontamination and then fire. Comparison of the gas chromatography-mass spectrometry (GC-MS) profiles of VX and its impurities/degradation products from contaminated burnt soil, and burnt soil spiked with VX, indicated that the fire resulted in the production of diethyl methylphosphonate and O,S-diethyl methylphosphonothiolate (by an unknown mechanism). Other products identified were indicative of chemical decontamination, and some of these provided evidence of the decontaminant used, for example, ethyl 2-methoxyethyl methylphosphonate and bis(2-methoxyethyl) methylphosphonate following decontamination with DS2. Sample preparation procedures and analytical methods suitable for investigating accelerant and decontaminant-soaked soil samples are presented. VX and its degradation products and/or impurities were detected under all the conditions studied, demonstrating that accelerant-based fire and liquid-based decontamination and then fire are unlikely to prevent the retrieval of evidence of chemical warfare agent (CWA) testing. This is the first published study of the effects of an accelerant-based fire on a CWA in environmental samples. The results will inform defence and security-based organisations worldwide and support the verification activities of the Organisation for the Prohibition of Chemical Weapons (OPCW), winner of the 2013 Nobel Peace Prize for its extensive efforts to eliminate chemical weapons.
Ultimately Reliable Pyrotechnic Systems
NASA Technical Reports Server (NTRS)
Scott, John H.; Hinkel, Todd
2015-01-01
This paper presents the methods by which NASA has designed, built, tested, and certified pyrotechnic devices for high reliability operation in extreme environments and illustrates the potential applications in the oil and gas industry. NASA's extremely successful application of pyrotechnics is built upon documented procedures and test methods that have been maintained and developed since the Apollo Program. Standards are managed and rigorously enforced for performance margins, redundancy, lot sampling, and personnel safety. The pyrotechnics utilized in spacecraft include such devices as small initiators and detonators with the power of a shotgun shell, detonating cord systems for explosive energy transfer across many feet, precision linear shaped charges for breaking structural membranes, and booster charges to actuate valves and pistons. NASA's pyrotechnics program is one of the more successful in the history of Human Spaceflight. No pyrotechnic device developed in accordance with NASA's Human Spaceflight standards has ever failed in flight use. NASA's pyrotechnic initiators work reliably in temperatures as low as -420 F. Each of the 135 Space Shuttle flights fired 102 of these initiators, some setting off multiple pyrotechnic devices, with never a failure. The recent landing on Mars of the Opportunity rover fired 174 of NASA's pyrotechnic initiators to complete the famous '7 minutes of terror.' Even after traveling through extreme radiation and thermal environments on the way to Mars, every one of them worked. These initiators have fired on the surface of Titan. NASA's design controls, procedures, and processes produce the most reliable pyrotechnics in the world. Application of pyrotechnics designed and procured in this manner could enable the energy industry's emergency equipment, such as shutoff valves and deep-sea blowout preventers, to be left in place for years in extreme environments and still be relied upon to function when needed, thus greatly enhancing safety and operational availability.
[Effect of Ti bonder on the bond strength between porcelain and titanium].
Yao, Hai; Luo, Xiao-ping
2009-12-01
To investigate the influence of GC Initial Ti Bonder on bond strength between Vita Titankeramik porcelain and titanium. Forty titanium samples were prepared and randomly assigned to 4 groups with 10 samples in each group. Samples in each group were subjected to one of the following surface treatments, burnishing (Group B), sandblasting (Group S), firing GC Initial Ti Bonder after burnishing (Group BG) and firing GC Initial Ti Bonder after sandblasting (Group SG). Vita Titankeramik porcelain were fired on the surface of each sample in the middle. Three-point bending tests were conducted on each sample according to the ISO 9693. The fracture patterns of all specimens were recorded using zoom stereo microscope (ZSM) and the fracture surfaces were observed under scanning electron microscope (SEM). With fired GC Initial Ti Bonder, the bond strength of Vita Titankeramik porcelain to titanium in Group BG and Group SG were (32.72 +/- 4.46) and (34.25 +/- 6.52) MPa respectively, which reach the ISO 9693 standard for clinical use and were significantly higher than those in Group B [(20.70 +/- 3.15) MPa] and Group S [(23.92 +/- 5.02) MPa]. GC Initial Ti Bonder can significantly improve bond strength between Vita Titankeramik porcelain and titanium.
Environmental Monitoring of a Titan 34D 5 1/2 Segment Solid Rocket Motor Static Firing.
1988-03-01
concentrations. The sampling scheme called for three near - field sampling sites (AFAL Experimental Areas 1-90, 1-100, and the Receiving, Inspection and Storage...regeneration from acidic rainout. 4. Field -testing the Aerospace and AFESC/LLNL experimental HCI monitors. The firing was first attempted on 4 June...was designed to take advantage of the specified wind corridor, and provided for both near - field and far- field sampling of ground-level HCI
16 CFR 1630.4 - Test procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the...) Gloves. Nonhygroscopic gloves (such as rubber polyethylene) for handling the sample after drying, and...
16 CFR 1630.4 - Test procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the...) Gloves. Nonhygroscopic gloves (such as rubber polyethylene) for handling the sample after drying, and...
Olivella, M A; Ribalta, T G; de Febrer, A R; Mollet, J M; de Las Heras, F X C
2006-02-15
Extensive forest fires occurred in Catalonia, northern Spain, in 1994. In our study, concentrations and profiles of 12 parent polycyclic aromatic hydrocarbons (PAHs) were determined in riverine waters, ash and sediment samples at nine sampling sites (W1-W9) and at three sampling dates from Llobregat hydrographic basin: in August, 1994, one month after the extensive forest fires; in September, 1994, after the first heavy autumn rainfalls and in January, 1995, six months after forest fires. In August 1994, the total concentrations of 12 PAHs measured in riverine waters varied from 2 ng/l to 336 ng/l. In September 1994, the total PAH concentrations decreased to 0.2-31 ng/l and in January 1995, from 9 ng/l to 73 ng/l. In August, the composition pattern of PAHs showed a distribution dominated by 4-ring PAHs (pyrene, chrysene+triphenylene, benzo(a)anthracene) at W3-W6, W8 and W9 and 3-ring PAHs (phenanthrene) at W1, W2 and W7. In September, a preference by 3-ring PAHs (phenanthrene) at all sampling sites except W5 was shown and in January was clearly dominated by 4-ring PAHs (chrysene+triphenylene, pyrene, benzo(a)anthracene) at all sampling sites. In ash and sediment samples, the total concentrations of 12 PAHs ranged from 1.3 ng/g to 19 ng/g. The dominant compound was phenanthrene.
Randy Kolka; Brian Sturtevant; Philip Townsend; Jessica Miesel; Peter Wolter; Shawn Fraver; Tom DeSutter
2014-01-01
Forest fires are important contributors of C, N, and Hg to the atmosphere. In the fall of 2011, a large wildfire occurred in northern Minnesota and we were able to quickly access the area to sample the forest floor and mineral soil for C, N, and Hg pools. When compared with unburned reference soils, the mean loss of C resulting from fire in the forest floor and the...
The U.S. EPA operates the Environmental and Sustainable Technology Evaluation (ESTE) program to facilitate the deployment of innovative technologies through performance verification and information dissemination. This ESTE project involved evaluation of co-firing common woody bio...
75 FR 2481 - Sunshine Act; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-15
... installation and commissioning of a new gas-fired industrial water heater, manufactured by Energy Systems... its investigation into a natural gas explosion that occurred at the ConAgra production facility in... consider urgent recommendations to the National Fire Protection Association (NFPA), the American Gas...
Fire Regime and Land Abandonment in European Russia: Case Study of Smolensk Oblast
NASA Astrophysics Data System (ADS)
Krylov, A.; McCarty, J. L.; Potapov, P.; Turubanova, S.; Prishchepov, A. V.; Manisha, A.; Romanenkov, V.; Rukhovitch, D.; Koroleva, P.; Hansen, M.
2014-12-01
Fires in anthropogenically-dominated landscapes are generally attributed to ecosystem management, agriculture, and policy drivers. In European Russia, fire mainly occurring on agricultural lands, wetlands, and abandoned lands. In the agricultural practice in Russia prescribed fires are believed to increase pasture and hay productivity, suppress trees and shrub expansion, and reduce fire hazards, with fire frequency fire dependent on land use and agricultural practices. The large-scale socio-economic transition since the fall of the Soviet Union has led to changes in land use and land management, including land abandonment and changing agricultural practices. In June 2014, an extensive field campaign was completed in the Smolensk Oblast, located approximately two hundred kilometers west of Moscow on the border with Belarus. Our field sampling was based on circa 1985 Landsat-based forest cover map (Potapov et al., 2014). Points were randomly selected from the non-forested class of the 1985 classification, prior to the collapse of the Soviet Union. Of total field collects, 55% points were sampled on land in either early or late stage of abandonment, 15% from actively cropped fields, and 30% from hay or pasture. Fire frequency was calculated for the 108 field points using 1 km Moderate Resolution Imaging Spectroradiometer (MODIS) active fire data for years 2000-2014. Also we calculated percent of points burned in spring 2014 using 30 m Landsat 8 Operational Land Imager (OLI) data to derive burn scars. Actively cropped fields had lowest burn frequency while abandoned lands - early and late stage abandonment - had highest frequency. Fire frequency was significantly higher on wet soils than dry soils, with no relationship between fire frequency and tree canopy cover. We hypothesize, higher fire frequency on abandoned lands was likely due to greater fuel loads and because of traditional belief in rural Russia that fire is efficient way to suppress tree and shrub expansion.
Reconstructing grassland fire history using sedimentary charcoal: Considering count, size and shape.
Leys, Berangere A; Commerford, Julie L; McLauchlan, Kendra K
2017-01-01
Fire is a key Earth system process, with 80% of annual fire activity taking place in grassland areas. However, past fire regimes in grassland systems have been difficult to quantify due to challenges in interpreting the charcoal signal in depositional environments. To improve reconstructions of grassland fire regimes, it is essential to assess two key traits: (1) charcoal count, and (2) charcoal shape. In this study, we quantified the number of charcoal pieces in 51 sediment samples of ponds in the Great Plains and tested its relevance as a proxy for the fire regime by examining 13 potential factors influencing charcoal count, including various fire regime components (e.g. the fire frequency, the area burned, and the fire season), vegetation cover and pollen assemblages, and climate variables. We also quantified the width to length (W:L) ratio of charcoal particles, to assess its utility as a proxy of fuel types in grassland environments by direct comparison with vegetation cover and pollen assemblages. Our first conclusion is that charcoal particles produced by grassland fires are smaller than those produced by forest fires. Thus, a mesh size of 120μm as used in forested environments is too large for grassland ecosystems. We recommend counting all charcoal particles over 60μm in grasslands and mixed grass-forest environments to increase the number of samples with useful data. Second, a W:L ratio of 0.5 or smaller appears to be an indicator for fuel types, when vegetation surrounding the site is before composed of at least 40% grassland vegetation. Third, the area burned within 1060m of the depositional environments explained both the count and the area of charcoal particles. Therefore, changes in charcoal count or charcoal area through time indicate a change in area burned. The fire regimes of grassland systems, including both human and climatic influences on fire behavior, can be characterized by long-term charcoal records.
Reconstructing grassland fire history using sedimentary charcoal: Considering count, size and shape
Leys, Berangere A.; Commerford, Julie L.; McLauchlan, Kendra K.
2017-01-01
Fire is a key Earth system process, with 80% of annual fire activity taking place in grassland areas. However, past fire regimes in grassland systems have been difficult to quantify due to challenges in interpreting the charcoal signal in depositional environments. To improve reconstructions of grassland fire regimes, it is essential to assess two key traits: (1) charcoal count, and (2) charcoal shape. In this study, we quantified the number of charcoal pieces in 51 sediment samples of ponds in the Great Plains and tested its relevance as a proxy for the fire regime by examining 13 potential factors influencing charcoal count, including various fire regime components (e.g. the fire frequency, the area burned, and the fire season), vegetation cover and pollen assemblages, and climate variables. We also quantified the width to length (W:L) ratio of charcoal particles, to assess its utility as a proxy of fuel types in grassland environments by direct comparison with vegetation cover and pollen assemblages. Our first conclusion is that charcoal particles produced by grassland fires are smaller than those produced by forest fires. Thus, a mesh size of 120μm as used in forested environments is too large for grassland ecosystems. We recommend counting all charcoal particles over 60μm in grasslands and mixed grass-forest environments to increase the number of samples with useful data. Second, a W:L ratio of 0.5 or smaller appears to be an indicator for fuel types, when vegetation surrounding the site is before composed of at least 40% grassland vegetation. Third, the area burned within 1060m of the depositional environments explained both the count and the area of charcoal particles. Therefore, changes in charcoal count or charcoal area through time indicate a change in area burned. The fire regimes of grassland systems, including both human and climatic influences on fire behavior, can be characterized by long-term charcoal records. PMID:28448597
Butt rot defect and potential hazard in lodgepole pine on selected California recreational areas
Lee A. Paine
1966-01-01
Within the area sampled, potentially hazardous lodgepole pine were common on recreational sites. The incidence of decayed and mechanically weak trees was correlated with fire damage. Two-thirds of fire-scarred trees were decayed; one-third were rated potentially hazardous. Fire scars occurred roughly in proportion to level of plot recreational use.
Multi-temporal LiDAR and Landsat quantification of fire-induced changes to forest structure
T. Ryan McCarley; Crystal A. Kolden; Nicole M. Vaillant; Andrew T. Hudak; Alistair M. S. Smith; Brian M. Wing; Bryce S. Kellogg; Jason Kreitler
2017-01-01
Measuring post-fire effects at landscape scales is critical to an ecological understanding of wildfire effects. Predominantly this is accomplished with either multi-spectral remote sensing data or through ground-based field sampling plots.While these methods are important, field data is usually limited to opportunistic post-fire observations, and spectral data often...
Prefire and postfire erosion of soil nutrients within a chaparral watershed
Jason P. de Koff; Robert C. Graham; Ken R. Hubbert; Peter M. Wohlgemuth
2006-01-01
Prescribed burns are an effective and increasingly popular strategy for inhibiting wildfires. The goal of this study was to characterize soil nutrient loss after a prescribed fire within a chaparral watershed in southern California. The study compared hillslope sediments for approximately 1 year before the fire with those during the year after the fire. Samples were...
Who starts forest fires in Maine - and how?
Wayne G. Banks; Fred E. Holt
1966-01-01
In 1964 the Maine Forest Service, in cooperation with the Northeastern Forest Experiment Station, conducted intensive investigations of a systematically selected sample of the fires that occurred in the State that year. The immediate purpose was to determine precisely how the fires started and who or what started them, and to assemble relevant information about the...
Mengucci, P; Gatto, A; Bassoli, E; Denti, L; Fiori, F; Girardin, E; Bastianoni, P; Rutkowski, B; Czyrska-Filemonowicz, A; Barucca, G
2017-07-01
Direct Metal Laser Sintering (DMLS) technology was used to produce tensile and flexural samples based on the Ti-6Al-4V biomedical composition. Tensile samples were produced in three different orientations in order to investigate the effect of building direction on the mechanical behavior. On the other hand, flexural samples were submitted to thermal treatments to simulate the firing cycle commonly used to veneer metallic devices with ceramics in dental applications. Roughness and hardness measurements as well as tensile and flexural mechanical tests were performed to study the mechanical response of the alloy while X-ray diffraction (XRD), electron microscopy (SEM, TEM, STEM) techniques and microanalysis (EDX) were used to investigate sample microstructure. Results evidenced a difference in the mechanical response of tensile samples built in orthogonal directions. In terms of microstructure, samples not submitted to the firing cycle show a single phase acicular α' (hcp) structure typical of metal parts subject to high cooling rates. After the firing cycle, samples show a reduction of hardness and strength due to the formation of laths of the β (bcc) phase at the boundaries of the primary formed α' plates as well as to lattice parameters variation of the hcp phase. Element partitioning during the firing cycle gives rise to high concentration of V atoms (up to 20wt%) at the plate boundaries where the β phase preferentially forms. Copyright © 2017 Elsevier Ltd. All rights reserved.
England, Glenn C; Watson, John G; Chow, Judith C; Zielinska, Barbara; Chang, M C Oliver; Loos, Karl R; Hidy, George M
2007-01-01
With the recent focus on fine particle matter (PM2.5), new, self-consistent data are needed to characterize emissions from combustion sources. Such data are necessary for health assessment and air quality modeling. To address this need, emissions data for gas-fired combustors are presented here, using dilution sampling as the reference. The dilution method allows for collection of emitted particles under conditions simulating cooling and dilution during entry from the stack into the air. The sampling and analysis of the collected particles in the presence of precursor gases, SO2 nitrogen oxide, volatile organic compound, and NH3 is discussed; the results include data from eight gas fired units, including a dual-fuel institutional boiler and a diesel engine powered electricity generator. These data are compared with results in the literature for heavy-duty diesel vehicles and stationary sources using coal or wood as fuels. The results show that the gas-fired combustors have very low PM2.5 mass emission rates in the range of approximately 10(-4) lb/million Btu (MMBTU) compared with the diesel backup generator with particle filter, with approximately 5 x 10(-3) lb/MMBTU. Even higher mass emission rates are found in coal-fired systems, with rates of approximately 0.07 lb/MMBTU for a bag-filter-controlled pilot unit burning eastern bituminous coal. The characterization of PM2.5 chemical composition from the gas-fired units indicates that much of the measured primary particle mass in PM2.5 samples is organic or elemental carbon and, to a much less extent, sulfate. Metal emissions are quite low compared with the diesel engines and the coal- or wood-fueled combustors. The metals found in the gas-fired combustor particles are low in concentration, similar in concentration to ambient particles. The interpretation of the particulate carbon emissions is complicated by the fact that an approximately equal amount of particulate carbon (mainly organic carbon) is found on the particle collector and a backup filter. It is likely that measurement artifacts, mostly adsorption of volatile organic compounds on quartz filters, are positively biasing "true" particulate carbon emission results.
NASA Astrophysics Data System (ADS)
Fonseca, Felícia; de Figueiredo, Tomás; Leite, Micaela
2014-05-01
Human induced fire in scrublands to obtain better pastures for cattle is a relatively common practice in North Portugal. During burning, plant cover and litter layers are consumed, and the mineral soil is heated, resulting in changes to physical, chemical, mineralogical, and biological soil properties. Aiming at evaluating the effect of this kind of fires on a set of physical and chemical soil properties, two study areas were selected in contrasting mountain environments: Edroso, Vinhais municipality, NE Portugal, with typical Mediterranean climate, and Revelhe, Fafe, NW Portugal, with a strong ocean-influenced climate. In both, sampling was carried out in contiguous areas burnt and not burnt, covered by shrub vegetation, predominantly Cytisus multiflorus and Ulex europeus. In each study area (Edroso and Revelhe) 16 locations were selected for soil sampling (8 in the burned area and 8 in the not burnt area), six months after fire occurrence. Disturbed soil samples were collected in the layers 0-5, 5-10, 10-15, 15-20 and 20-30 cm depth, for assessing organic matter, N, P and K concentration, cation exchange capacity and related determinations, soil pH, electrical conductivity and soil texture. Undisturbed samples were collected, in 100 cm3 cylinders, to determine bulk density in the same above mentioned layers, and permeability in the 0-5 cm layer. Compared results of burnt and not burnt areas in Edroso and Revelhe study sites, show that coarse elements content and permeability decreased and bulk density slightly increased with the fire effect. Chemical properties in both sites changed with after fire, as organic matter content, exchangeable Al and cation exchange capacity increased, the opposite trend being found for phosphorus, sum of exchangeable bases and electrical conductivity. Potassium, total nitrogen and exchangeable acidity showed different soil responses to fire in the two study areas. Results stress the clear effects of fire on fertility related soil properties, not only chemical but also physical, which is decisive for the post-fire recover of burnt shrub communities, in terms of vegetation and soil functions in these marginal mountain environments.
Oygard, Joar Karsten; Måge, Amund; Gjengedal, Elin; Svane, Tore
2005-01-01
Landfill leachates sampled during and after an accidental landfill fire were analysed and the levels of selected metals and chemical compounds compared to those occurring in the leachate under normal conditions. The fire at the landfill site was put out by excavation and cooling by use of water. The investigation during the fire and fire fight revealed a moderate increase in the level of nitrogen and also in pH and conductivity. Heavy metals and COD in the leachate showed considerably increased levels. In general, the determined variables appeared to normalise within one week after the fire was extinguished. It can be concluded that landfill fires extinguished by excavation may lead to elevated leachate levels of especially COD and heavy metals, but that this is only a short-term effect.
Quantification of prairie restoration for phytostability at a remediated defense plant.
Franson, Raymond L; Scholes, Chad M
2011-01-01
In June 2008 and 2009, cover, density, and species diversity were measured on two areas of the prairie at the U. S. Department of Energy Weldon Spring Site to begin quantification of the prairie establishment and the effects of a prairie burn. Sampling began by testing for the most appropriate transect length (cover) and quadrat size (density) for quantification of vegetation. Total cover increased in the first growing season after burning. Conversely, total cover decreased in the unburned area in one year. The trend in litter cover is the opposite with litter decreasing after burning, but increasing in one year in the unburned area. Bare ground decreased in one year in the unburned area, but was unchanged after burning. Species diversity tripled after fire, but was unchanged in one year in the unburned area. The results show that litter and fire both affect plant cover. If land reclamation activities are to be an integral part of hazardous waste remediation at contaminated sites, then the success of reclamation efforts needs to be quantified along with success criteria for waste remediation of the sites. The results show that plant cover can be easily quantified, but that density measures are more biased which makes it more difficult to achieve adequate sample size for plant density.
Fent, Kenneth W; Alexander, Barbara; Roberts, Jennifer; Robertson, Shirley; Toennis, Christine; Sammons, Deborah; Bertke, Stephen; Kerber, Steve; Smith, Denise; Horn, Gavin
2017-10-01
Firefighters' skin may be exposed to chemicals via permeation/penetration of combustion byproducts through or around personal protective equipment (PPE) or from the cross-transfer of contaminants on PPE to the skin. Additionally, volatile contaminants can evaporate from PPE following a response and be inhaled by firefighters. Using polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) as respective markers for non-volatile and volatile substances, we investigated the contamination of firefighters' turnout gear and skin following controlled residential fire responses. Participants were grouped into three crews of twelve firefighters. Each crew was deployed to a fire scenario (one per day, four total) and then paired up to complete six fireground job assignments. Wipe sampling of the exterior of the turnout gear was conducted pre- and post-fire. Wipe samples were also collected from a subset of the gear after field decontamination. VOCs off-gassing from gear were also measured pre-fire, post-fire, and post-decon. Wipe sampling of the firefighters' hands and neck was conducted pre- and post-fire. Additional wipes were collected after cleaning neck skin. PAH levels on turnout gear increased after each response and were greatest for gear worn by firefighters assigned to fire attack and to search and rescue activities. Field decontamination using dish soap, water, and scrubbing was able to reduce PAH contamination on turnout jackets by a median of 85%. Off-gassing VOC levels increased post-fire and then decreased 17-36 min later regardless of whether field decontamination was performed. Median post-fire PAH levels on the neck were near or below the limit of detection (< 24 micrograms per square meter [µg/m 2 ]) for all positions. For firefighters assigned to attack, search, and outside ventilation, the 75 th percentile values on the neck were 152, 71.7, and 39.3 µg/m 2 , respectively. Firefighters assigned to attack and search had higher post-fire median hand contamination (135 and 226 µg/m 2 , respectively) than other positions (< 10.5 µg/m 2 ). Cleansing wipes were able to reduce PAH contamination on neck skin by a median of 54%.
Rawhide Energy Station, Fort Collins, Colorado
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peltier, R.
2008-10-15
The staff of Platte River Power Authority's Rawhide Energy Station have been racking up operating stats and an environmental performance record that is the envy of other plant managers. In the past decade Rawhide has enjoyed an equivalent availability factor in the mid to high 90s and an average capacity factor approaching 90%. Still not content with this performance, Rawhide invested in new technology and equipment upgrades to further optimise performance, reduce emissions, and keep cost competitive. The Energy Station includes four GE France 7EA natural gas-fired turbines totalling 260 MW and a 274 MW coal-fired unit located in northeasternmore » Colorado. 7 figs.« less
Reducing Conservatism of Analytic Transient Response Bounds via Shaping Filters
NASA Technical Reports Server (NTRS)
Kwan, Aiyueh; Bedrossian, Nazareth; Jan, Jiann-Woei; Grigoriadis, Karolos; Hua, Tuyen (Technical Monitor)
1999-01-01
Recent results show that the peak transient response of a linear system to bounded energy inputs can be computed using the energy-to-peak gain of the system. However, analytically computed peak response bound can be conservative for a class of class bounded energy signals, specifically pulse trains generated from jet firings encountered in space vehicles. In this paper, shaping filters are proposed as a Methodology to reduce the conservatism of peak response analytic bounds. This Methodology was applied to a realistic Space Station assembly operation subject to jet firings. The results indicate that shaping filters indeed reduce the predicted peak response bounds.
Organtini, Kari L; Myers, Anne L; Jobst, Karl J; Reiner, Eric J; Ross, Brian; Ladak, Adam; Mullin, Lauren; Stevens, Douglas; Dorman, Frank L
2015-10-20
Residential and commercial fires generate a complex mixture of volatile, semivolatile, and nonvolatile compounds. This study focused on the semi/nonvolatile components of fire debris to better understand firefighter exposure risks. Using the enhanced sensitivity of gas chromatography coupled to atmospheric pressure ionization-tandem mass spectrometry (APGC-MS/MS), complex fire debris samples collected from simulation fires were analyzed for the presence of potentially toxic polyhalogenated dibenzo-p-dioxins and dibenzofurans (PXDD/Fs and PBDD/Fs). Extensive method development was performed to create multiple reaction monitoring (MRM) methods for a wide range of PXDD/Fs from dihalogenated through hexa-halogenated homologue groups. Higher halogenated compounds were not observed due to difficulty eluting them off the long column used for analysis. This methodology was able to identify both polyhalogenated (mixed bromo-/chloro- and polybromo-) dibenzo-p-dioxins and dibenzofurans in the simulated burn study samples collected, with the dibenzofuran species being the dominant compounds in the samples. Levels of these compounds were quantified as total homologue groups due to the limitations of commercial congener availability. Concentration ranges in household simulation debris were observed at 0.01-5.32 ppb (PXDFs) and 0.18-82.11 ppb (PBDFs). Concentration ranges in electronics simulation debris were observed at 0.10-175.26 ppb (PXDFs) and 0.33-9254.41 ppb (PBDFs). Samples taken from the particulate matter coating the firefighters' helmets contained some of the highest levels of dibenzofurans, ranging from 4.10 ppb to 2.35 ppm. The data suggest that firefighters and first responders at fire scenes are exposed to a complex mixture of potentially hundreds to thousands of different polyhalogenated dibenzo-p-dioxins and dibenzofurans that could negatively impact their health.
Reported fire safety and first-aid amenities in Airbnb venues in 16 American cities.
Kennedy, Hudson R; Jones, Vanya C; Gielen, Andrea
2018-05-07
Airbnb helps hosts rent all or part of their home to guests as an alternative to traditional hospitality settings. Airbnb venues are not uniformly regulated across the USA. This study quantified the reported prevalence of fire safety and first-aid amenities in Airbnb venues in the USA. The sample includes 120 691 venues in 16 US cities. Proportions of host-reported smoke and carbon monoxide (CO) detectors, fire extinguishers and first-aid kits were calculated. The proportion of venues that reportedly contained amenities are as follows: smoke detectors 80% (n=96 087), CO detectors 57.5% (n=69 346), fire extinguishers 42% (n=50 884) and first-aid kits 36% (n=43 497). Among this sample of Airbnb venues, safety deficiencies were noted. While most venues had smoke alarms, approximately 1/2 had CO alarms and less than 1/2 reported having a fire extinguishers or first-aid kits. Local and state governments or Airbnb must implement regulations compliant with current National Fire Protection Association fire safety standards. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Effect of ecosystem type and fire on chemistry of WEOM as measured by LDI-TOF-MS and NMR.
Crecelius, Anna C; Vitz, Jürgen; Näthe, Kerstin; Meyer, Stefanie; Michalzik, Beate; Schubert, Ulrich S
2017-01-01
Soil organic matter (SOM) and its water-soluble components play an important role in terrestrial carbon cycling and associated ecosystem functions. Chemically, they are complex mixtures of organic compounds derived from decomposing plant material, microbial residues, as well as root exudates, and soil biota. To test the effect of the ecosystem type (forest and grassland) and fires events on the chemistry of dissolved organic matter (DOM), we applied a combination of laser-desorption/ionization time-of-flight mass spectrometry (LDI-TOF-MS) and 2D ( 1 H and 13 C) nuclear magnetic resonance (NMR) spectroscopy to water-extractable organic matter (WEOM) from a range of top soil samples. The aim was to assess the suitability of LDI-TOF-MS for the rapid characterization of WEOM. Therefore, we evaluated the effects of sample (pH and dilution) conditions and use of positive or negative reflector mode to identify the conditions under which LDI-TOF-MS best distinguished between WEOM from different sources. Thirty-six samples were measured with both analytical techniques and their chemical patterns were statistically evaluated to distinguish firstly the effect of the type of ecosystem (forest versus grassland) on WEOM characteristics, and secondly the impact of fire on the chemical composition of WEOM. The nonmetric multidimensional scaling (NMDS) analysis of the most suitable experimental LDI-TOF-MS conditions showed a clear separation between the type of vegetation and fire-induced changes, mostly reflecting the presence of poly(ethylene glycol) in grassland soils. Discrimination among WEOM from different vegetation types was preserved in the fire treated samples. The calculation of the relative abundance of certain functional structures in the WEOM samples revealed a common composition of forest and grassland WEOM, with polysaccharides and proteins making up to 60%. The compositional impact of forest fire on WEOM was more pronounced compared to the one of grassland, leading to a decline in the main components, and an increase in amino-sugars, fatty acids, and sterols. The recorded 1 H NMR and heteronuclear single quantum coherence (HSQC) spectra showed a decrease of the carbohydrate signal in WEOM from fire-treated samples, which was more pronounced in forest than in grassland soils. Copyright © 2016 Elsevier B.V. All rights reserved.
Emissions of nitrous oxide from biomass burning
NASA Technical Reports Server (NTRS)
Winstead, Edward L.; Cofer, Wesley R., III; Levine, Joel S.
1991-01-01
A study has been conducted which compared N2O results obtained over large prescribed fires or wildfires, in which 'grab-sampling' with storage had been used with N2O measurements made in near-real time. CO2-normalized emission ratios obtained initially from the laboratory fires are substantially lower than those obtained over large-scale biomass fires. Combustion may not be the only source of N2O in large fire smoke plumes; physical, chemical, and biochemical processes in the soil may be altered by large biomass fires, leading to large N2O releases.
NASA Astrophysics Data System (ADS)
Tohidi, Ali; Gollner, Michael J.; Xiao, Huahua
2018-01-01
Fire whirls present a powerful intensification of combustion, long studied in the fire research community because of the dangers they present during large urban and wildland fires. However, their destructive power has hidden many features of their formation, growth, and propagation. Therefore, most of what is known about fire whirls comes from scale modeling experiments in the laboratory. Both the methods of formation, which are dominated by wind and geometry, and the inner structure of the whirl, including velocity and temperature fields, have been studied at this scale. Quasi-steady fire whirls directly over a fuel source form the bulk of current experimental knowledge, although many other cases exist in nature. The structure of fire whirls has yet to be reliably measured at large scales; however, scaling laws have been relatively successful in modeling the conditions for formation from small to large scales. This review surveys the state of knowledge concerning the fluid dynamics of fire whirls, including the conditions for their formation, their structure, and the mechanisms that control their unique state. We highlight recent discoveries and survey potential avenues for future research, including using the properties of fire whirls for efficient remediation and energy generation.
NASA Astrophysics Data System (ADS)
Sofiev, Mikhail; Soares, Joana; Kouznetsov, Rostislav; Vira, Julius; Prank, Marje
2016-04-01
Top-down emission estimation via inverse dispersion modelling is used for various problems, where bottom-up approaches are difficult or highly uncertain. One of such areas is the estimation of emission from wild-land fires. In combination with dispersion modelling, satellite and/or in-situ observations can, in principle, be used to efficiently constrain the emission values. This is the main strength of the approach: the a-priori values of the emission factors (based on laboratory studies) are refined for real-life situations using the inverse-modelling technique. However, the approach also has major uncertainties, which are illustrated here with a few examples of the Integrated System for wild-land Fires (IS4FIRES). IS4FIRES generates the smoke emission and injection profile from MODIS and SEVIRI active-fire radiative energy observations. The emission calculation includes two steps: (i) initial top-down calibration of emission factors via inverse dispersion problem solution that is made once using training dataset from the past, (ii) application of the obtained emission coefficients to individual-fire radiative energy observations, thus leading to bottom-up emission compilation. For such a procedure, the major classes of uncertainties include: (i) imperfect information on fires, (ii) simplifications in the fire description, (iii) inaccuracies in the smoke observations and modelling, (iv) inaccuracies of the inverse problem solution. Using examples of the fire seasons 2010 in Russia, 2012 in Eurasia, 2007 in Australia, etc, it is pointed out that the top-down system calibration performed for a limited number of comparatively moderate cases (often the best-observed ones) may lead to errors in application to extreme events. For instance, the total emission of 2010 Russian fires is likely to be over-estimated by up to 50% if the calibration is based on the season 2006 and fire description is simplified. Longer calibration period and more sophisticated parameterization (including the smoke injection model and distinguishing all relevant vegetation types) can improve the predictions. The other significant parameter, so far weakly addressed in fire emission inventories, is the size spectrum of the emitted aerosols. Direct size-resolving measurements showed, for instance, that smoke from smouldering fires has smaller particles as compares with smoke from flaming fires. Due to dependence of the smoke optical thickness on the size distribution, such variability can lead to significant changes in the top-down calibration step. Experiments with IS4FIRES-SILAM system manifested up to a factor of two difference in AOD, depending on the assumption on particle spectrum.
Minimum energy control for in vitro neurons.
Nabi, Ali; Stigen, Tyler; Moehlis, Jeff; Netoff, Theoden
2013-06-01
To demonstrate the applicability of optimal control theory for designing minimum energy charge-balanced input waveforms for single periodically-firing in vitro neurons from brain slices of Long-Evans rats. The method of control uses the phase model of a neuron and does not require prior knowledge of the neuron's biological details. The phase model of a neuron is a one-dimensional model that is characterized by the neuron's phase response curve (PRC), a sensitivity measure of the neuron to a stimulus applied at different points in its firing cycle. The PRC for each neuron is experimentally obtained by measuring the shift in phase due to a short-duration pulse injected into the periodically-firing neuron at various phase values. Based on the measured PRC, continuous-time, charge-balanced, minimum energy control waveforms have been designed to regulate the next firing time of the neuron upon application at the onset of an action potential. The designed waveforms can achieve the inter-spike-interval regulation for in vitro neurons with energy levels that are lower than those of conventional monophasic pulsatile inputs of past studies by at least an order of magnitude. They also provide the advantage of being charge-balanced. The energy efficiency of these waveforms is also shown by performing several supporting simulations that compare the performance of the designed waveforms against that of phase shuffled surrogate inputs, variants of the minimum energy waveforms obtained from suboptimal PRCs, as well as pulsatile stimuli that are applied at the point of maximum PRC. It was found that the minimum energy waveforms perform better than all other stimuli both in terms of control and in the amount of energy used. Specifically, it was seen that these charge-balanced waveforms use at least an order of magnitude less energy than conventional monophasic pulsatile stimuli. The significance of this work is that it uses concepts from the theory of optimal control and introduces a novel approach in designing minimum energy charge-balanced input waveforms for neurons that are robust to noise and implementable in electrophysiological experiments.
Minimum energy control for in vitro neurons
NASA Astrophysics Data System (ADS)
Nabi, Ali; Stigen, Tyler; Moehlis, Jeff; Netoff, Theoden
2013-06-01
Objective. To demonstrate the applicability of optimal control theory for designing minimum energy charge-balanced input waveforms for single periodically-firing in vitro neurons from brain slices of Long-Evans rats. Approach. The method of control uses the phase model of a neuron and does not require prior knowledge of the neuron’s biological details. The phase model of a neuron is a one-dimensional model that is characterized by the neuron’s phase response curve (PRC), a sensitivity measure of the neuron to a stimulus applied at different points in its firing cycle. The PRC for each neuron is experimentally obtained by measuring the shift in phase due to a short-duration pulse injected into the periodically-firing neuron at various phase values. Based on the measured PRC, continuous-time, charge-balanced, minimum energy control waveforms have been designed to regulate the next firing time of the neuron upon application at the onset of an action potential. Main result. The designed waveforms can achieve the inter-spike-interval regulation for in vitro neurons with energy levels that are lower than those of conventional monophasic pulsatile inputs of past studies by at least an order of magnitude. They also provide the advantage of being charge-balanced. The energy efficiency of these waveforms is also shown by performing several supporting simulations that compare the performance of the designed waveforms against that of phase shuffled surrogate inputs, variants of the minimum energy waveforms obtained from suboptimal PRCs, as well as pulsatile stimuli that are applied at the point of maximum PRC. It was found that the minimum energy waveforms perform better than all other stimuli both in terms of control and in the amount of energy used. Specifically, it was seen that these charge-balanced waveforms use at least an order of magnitude less energy than conventional monophasic pulsatile stimuli. Significance. The significance of this work is that it uses concepts from the theory of optimal control and introduces a novel approach in designing minimum energy charge-balanced input waveforms for neurons that are robust to noise and implementable in electrophysiological experiments.
Biological and geophysical feedbacks with fire in the Earth system
NASA Astrophysics Data System (ADS)
Archibald, S.; Lehmann, C. E. R.; Belcher, C. M.; Bond, W. J.; Bradstock, R. A.; Daniau, A.-L.; Dexter, K. G.; Forrestel, E. J.; Greve, M.; He, T.; Higgins, S. I.; Hoffmann, W. A.; Lamont, B. B.; McGlinn, D. J.; Moncrieff, G. R.; Osborne, C. P.; Pausas, J. G.; Price, O.; Ripley, B. S.; Rogers, B. M.; Schwilk, D. W.; Simon, M. F.; Turetsky, M. R.; Van der Werf, G. R.; Zanne, A. E.
2018-03-01
Roughly 3% of the Earth’s land surface burns annually, representing a critical exchange of energy and matter between the land and atmosphere via combustion. Fires range from slow smouldering peat fires, to low-intensity surface fires, to intense crown fires, depending on vegetation structure, fuel moisture, prevailing climate, and weather conditions. While the links between biogeochemistry, climate and fire are widely studied within Earth system science, these relationships are also mediated by fuels—namely plants and their litter—that are the product of evolutionary and ecological processes. Fire is a powerful selective force and, over their evolutionary history, plants have evolved traits that both tolerate and promote fire numerous times and across diverse clades. Here we outline a conceptual framework of how plant traits determine the flammability of ecosystems and interact with climate and weather to influence fire regimes. We explore how these evolutionary and ecological processes scale to impact biogeochemical and Earth system processes. Finally, we outline several research challenges that, when resolved, will improve our understanding of the role of plant evolution in mediating the fire feedbacks driving Earth system processes. Understanding current patterns of fire and vegetation, as well as patterns of fire over geological time, requires research that incorporates evolutionary biology, ecology, biogeography, and the biogeosciences.
Impacts: NIST Building and Fire Research Laboratory (technical and societal)
NASA Astrophysics Data System (ADS)
Raufaste, N. J.
1993-08-01
The Building and Fire Research Laboratory (BFRL) of the National Institute of Standards and Technology (NIST) is dedicated to the life cycle quality of constructed facilities. The report describes major effects of BFRL's program on building and fire research. Contents of the document include: structural reliability; nondestructive testing of concrete; structural failure investigations; seismic design and construction standards; rehabilitation codes and standards; alternative refrigerants research; HVAC simulation models; thermal insulation; residential equipment energy efficiency; residential plumbing standards; computer image evaluation of building materials; corrosion-protection for reinforcing steel; prediction of the service lives of building materials; quality of construction materials laboratory testing; roofing standards; simulating fires with computers; fire safety evaluation system; fire investigations; soot formation and evolution; cone calorimeter development; smoke detector standards; standard for the flammability of children's sleepwear; smoldering insulation fires; wood heating safety research; in-place testing of concrete; communication protocols for building automation and control systems; computer simulation of the properties of concrete and other porous materials; cigarette-induced furniture fires; carbon monoxide formation in enclosure fires; halon alternative fire extinguishing agents; turbulent mixing research; materials fire research; furniture flammability testing; standard for the cigarette ignition resistance of mattresses; support of navy firefighter trainer program; and using fire to clean up oil spills.
Saikia, Jyotilima; Narzary, Bardwi; Roy, Sonali; Bordoloi, Manobjyoti; Saikia, Prasenjit; Saikia, Binoy K
2016-12-01
Studies on coal-derived nanoparticles as well as nano-minerals are important in the context of the human health and the environment. The coal combustion-generated aerosols also affect human health and environmental quality aspects in any coal-fired station. In this study, the feed coals and their combustion-generated aerosols from coal-fired boilers of two tea industry facilities were investigated for the presence of nanoparticles/nano minerals, fullerene aggregates, and potentially hazardous elements (PHEs). The samples were characterized by using X-ray diffraction (XRD), Time-of-flight secondary ion mass spectroscopy (TOF-SIMS), High resolution-transmission electron microscopy/energy dispersive spectroscopy (HR-TEM/EDS) and Ultra Violet-visible spectroscopy (UV-Vis) to know their extent of environmental risks to the human health when present in coals and aerosols. The feed coals contain mainly clay minerals, whilst glass fragments, spinel, quartz, and other minerals occur in lesser quantities. The PM samples contain potentially hazardous elements (PHEs) like As, Pb, Cd and Hg. Enrichment factor of the trace elements in particulate matters (PMs) was calculated to determine their sources. The aerosol samples were also found to contain nanomaterials and ultrafine particles. The fullerene aggregates along with potentially hazardous elements were also detected in the aerosol samples. The cytotoxicity studies on the coal combustion-generated PM samples show their potential risk to the human health. This detailed investigation on the inter-relationship between the feed coals and their aerosol chemistry will be useful for understanding the extent of environmental hazards and related human health risk. Copyright © 2016 Elsevier Ltd. All rights reserved.
Strategic oil reserves catch fire too
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crull, A.W.
The Federal strategic oil storage site at West Hackberry Dome in Louisiana caught fire in spite of DOE assurances that this is the safest way to store oil. Most of the oil was recovered, although confusion at the site aggravated the problem in getting the fire under control. DOE called the incident an industrial accident, but has not acknowledged the risks involved in all aspects of petroleum drilling or handling -- and the drastic limits of personnel able to handle resulting accidents. Inteviews with Boots and Coots, a team of fire fighters in Houston, provided the author with details ofmore » oil fires and ways to deal with them. The oil fire fighters point out that all energy source development and storage involves some risk and that steps should be taken to train personnel to deal with the negative aspects of petroleum.« less
Effects of fire on the state of several elements in some soils of Sardinia.
Senette, C; Meloni, S; Alberti, G; Melis, P
2000-01-01
In order to individuate the modifications induced in the soil by fires relatively to the mobility of metals and rare earth three soils of Sardinia which differ in their mineralogical and physico-chemical characteristics were sampled. The analytical results obtained on the samples drawn at different depths (0-5 and 10-30 cm) three months after a fire and on the tests indicate that only the surface layer underwent significant modifications. The dynamics of metals and the distribution of the rare earths were found to depend, besides the amount and quality of the burned material, on the different behaviour of elements towards leaching. The diffractometric analysis showed that the soil surface layer of all the samples did not exceed 400 degrees C.
Egidi, Eleonora; McMullan-Fisher, Sapphire; Morgan, John W; May, Tom; Zeeman, Ben; Franks, Ashley E
2016-09-01
Frequent burning is commonly undertaken to maintain diversity in temperate grasslands of southern Australia. How burning affects below-ground fungal community diversity remains unknown. We show, using a fungal rDNA metabarcoding approach (Illumina MiSeq), that the fungal community composition was influenced by fire regime (frequency) but not time-since-fire. Fungal community composition was resilient to direct fire effects, most likely because grassland fires transfer little heat to the soil. Differences in the fungal community composition due to fire regime was likely due to associated changes that occur in vegetation with recurrent fire, via the break up of obligate symbiotic relationships. However, fire history only partially explains the observed dissimilarity in composition among the soil samples, suggesting a distinctiveness in composition in each grassland site. The importance of considering changes in soil microbe communities when managing vegetation with fire is highlighted. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Tending the Fire, A Legacy Survey of Molecular Gas Fueling in Powerful Nearby AGN
NASA Astrophysics Data System (ADS)
Koss, Michael; BASS Team
2018-01-01
Over the last 30 years the importance of host galaxy molecular gas for growing black holes has been intensely debated. We have observed a a volume-limited sample of over 200 nearby powerful AGN (0.01 < z < 0.05, Lbol;AGN > 10^44 erg/s) using the CO 2-1 line with the JCMT and APEX telescopes to definitively address this issue. The AGN are selected from the Swift-BAT all sky hard X-ray survey which is superior to optical or IR selection since high energy X-rays (14-195 keV) are almost independent of host galaxy properties and obscuration. We compare our samples molecular gas properties to inactive galaxies selected with the IRAM 30m COLD GASS survey to understand the general trends with AGN activity.
Joint Long-Range Energy Study for Greater Fairbanks Military Complex
2005-02-01
be viewed as a two - stage processor of a fuel or feedstock. The feedstock is first gasified using high-temperature plasma heating sys- tems at...Coal-Fired Boilers with New Circulating Fluidized- Bed Boilers (CFBs). EAFB anticipates replacing two current boilers with two new boilers. This...definition to support DD Form 1391 budget level cost estimates for new coal-fired CHPPs at FWA and EAFB and for two new coal-fired CFBs at EAFB • update
Multiple Aspects of the Southern California Wildfires as Seen by NASA's AVIRIS
2017-12-15
NASA's Airborne Visible Infrared Imaging Spectrometer instrument (AVIRIS), flying aboard a NASA Armstrong Flight Research Center high-altitude ER-2 aircraft, observed wildfires burning in Southern California on Dec. 5-7, 2017. AVIRIS is an imaging spectrometer that observes light in visible and infrared wavelengths, measuring the full spectrum of radiated energy. Unlike regular cameras with three colors, AVIRIS has 224 spectral channels, measuring contiguously from the visible through the shortwave infrared. Data from these flights, compared against measurements acquired earlier in the year, show many ways this one instrument can improve both our understanding of fire risk and the response to fires in progress. The top row in this image compilation shows pre-fire data acquired from June 2017. At top left is a visible-wavelength image similar to what our own eyes would see. The top middle image is a map of surface composition based on analyzing the full electromagnetic spectrum, revealing green vegetated areas and non-photosynthetic vegetation that is potential fuel as well as non-vegetated surfaces that may slow an advancing fire. The image at top right is a remote measurement of the water in tree canopies, a proxy for how much moisture is in the vegetation. The bottom row in the compilation shows data acquired from the Thomas fire in progress in December 2017. At bottom left is a visible wavelength image. The bottom middle image is an infrared image, with red at 2,250 nanometers showing fire energy, green at 1,650 nanometers showing the surface through the smoke, and blue at 1,000 nanometers showing the smoke itself. The image at bottom right is a fire temperature map using spectroscopic analysis to measure fire thermal emission recorded in the AVIRIS spectra. https://photojournal.jpl.nasa.gov/catalog/PIA22194
A wireless sensor network deployment for rural and forest fire detection and verification.
Lloret, Jaime; Garcia, Miguel; Bri, Diana; Sendra, Sandra
2009-01-01
Forest and rural fires are one of the main causes of environmental degradation in Mediterranean countries. Existing fire detection systems only focus on detection, but not on the verification of the fire. However, almost all of them are just simulations, and very few implementations can be found. Besides, the systems in the literature lack scalability. In this paper we show all the steps followed to perform the design, research and development of a wireless multisensor network which mixes sensors with IP cameras in a wireless network in order to detect and verify fire in rural and forest areas of Spain. We have studied how many cameras, sensors and access points are needed to cover a rural or forest area, and the scalability of the system. We have developed a multisensor and when it detects a fire, it sends a sensor alarm through the wireless network to a central server. The central server selects the closest wireless cameras to the multisensor, based on a software application, which are rotated to the sensor that raised the alarm, and sends them a message in order to receive real-time images from the zone. The camera lets the fire fighters corroborate the existence of a fire and avoid false alarms. In this paper, we show the test performance given by a test bench formed by four wireless IP cameras in several situations and the energy consumed when they are transmitting. Moreover, we study the energy consumed by each device when the system is set up. The wireless sensor network could be connected to Internet through a gateway and the images of the cameras could be seen from any part of the world.
A Wireless Sensor Network Deployment for Rural and Forest Fire Detection and Verification
Lloret, Jaime; Garcia, Miguel; Bri, Diana; Sendra, Sandra
2009-01-01
Forest and rural fires are one of the main causes of environmental degradation in Mediterranean countries. Existing fire detection systems only focus on detection, but not on the verification of the fire. However, almost all of them are just simulations, and very few implementations can be found. Besides, the systems in the literature lack scalability. In this paper we show all the steps followed to perform the design, research and development of a wireless multisensor network which mixes sensors with IP cameras in a wireless network in order to detect and verify fire in rural and forest areas of Spain. We have studied how many cameras, sensors and access points are needed to cover a rural or forest area, and the scalability of the system. We have developed a multisensor and when it detects a fire, it sends a sensor alarm through the wireless network to a central server. The central server selects the closest wireless cameras to the multisensor, based on a software application, which are rotated to the sensor that raised the alarm, and sends them a message in order to receive real-time images from the zone. The camera lets the fire fighters corroborate the existence of a fire and avoid false alarms. In this paper, we show the test performance given by a test bench formed by four wireless IP cameras in several situations and the energy consumed when they are transmitting. Moreover, we study the energy consumed by each device when the system is set up. The wireless sensor network could be connected to Internet through a gateway and the images of the cameras could be seen from any part of the world. PMID:22291533
Microbial contents of soil from fire pits
NASA Astrophysics Data System (ADS)
Moon, K.; Esparza, V.; de Sandre, J.; Cheney, S.; Anderson, A.; White, M. A.
2006-12-01
Forest fires generate polycylic aromatic hydrocarbons (PAHs) that can lead to carcinogenic compounds, which are potential health risks. PAHs can be degraded to water and carbon dioxide by certain soil microbes. Thus, during participation in a NASA-funded summer research experience at Utah State University, our high school student team sampled soils from a month-old fire pit in which plant materials had been burnt. We detected in soil samples, from surface, 10 and 20 cm depths, microbes that would grow on a defined minimal medium source. Other microbes were cultured from the roots of plants that had established at the fire pit. A diversity of microbes was present in all samples based on visible differences in cell shape and color. It was surprising that the surface ash, although exposed to sunlight over the month interval, had culturable colonies. Many of these culturable bacteria were pigmented perhaps as a protection against UV radiation from the sun. We searched for genes in the microbes that encoded enzymes called dioxygenases that in other bacteria are involved in degradation of PAHs. This test involved using polymerase chain reactions to detect the genes. PCR products were found in two of the fifteen isolates tested although their sizes differed from the control gene product from a PAH-degrading mycobacterium isolate. These results suggest that the soils did contain microbes with the possible potential to alter the PAH compounds generated from vegetation fires. Our findings serve as a starting point for future studies looking at recovery and remediation of fired acreages.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, D.; Lewis, R.; Tobiasz, R.
1998-12-31
The composition and properties of ash formed during coal firing have a major impact on boiler performance. Higher ash content in the coal can mean higher costs associated with coal handling, transportation, ash removal and ash disposal along with higher costs due to the increased ash content`s deleterious effects on pulverizing, combustion and heat transfer. ABB C-E Services, Inc. has conducted research for many years on what might be done to minimize the adverse effects of ash on boiler performance. Recently, ABB C-E Services has studied the effects of firing system modifications on ash composition and properties and the effectmore » these firing system modifications have on overall furnace performance. The subject of this paper is the impact of the installation of the CFS Concentric Firing System on the propensity for boiler wall ash deposition. For this study, CFS yaw angles were varied and particle samples were collected at the waterwalls for the different yaw angles tested. These ash samples were analyzed for ash composition. The results showed that with a larger CFS yaw angle (the air stream directed more towards the boiler walls) the base/acid ratio, iron content and sulfur content of the particle samples collected at the waterwall were reduced. This effect is due to several contributing factors: (1) an oxidizing environment produced by injecting more air toward the walls; and (2) an aerodynamic change which impacts the particle combustion time/temperature history.« less
Sutcu, Mucahit; Ozturk, Savas; Yalamac, Emre; Gencel, Osman
2016-10-01
Production of porous clay bricks lightened by adding olive mill waste as a pore making additive was investigated. Factors influencing the brick manufacturing process were analyzed by an experimental design, Taguchi method, to find out the most favorable conditions for the production of bricks. The optimum process conditions for brick preparation were investigated by studying the effects of mixture ratios (0, 5 and 10 wt%) and firing temperatures (850, 950 and 1050 °C) on the physical, thermal and mechanical properties of the bricks. Apparent density, bulk density, apparent porosity, water absorption, compressive strength, thermal conductivity, microstructure and crystalline phase formations of the fired brick samples were measured. It was found that the use of 10% waste addition reduced the bulk density of the samples up to 1.45 g/cm(3). As the porosities increased from 30.8 to 47.0%, the compressive strengths decreased from 36.9 to 10.26 MPa at firing temperature of 950 °C. The thermal conductivities of samples fired at the same temperature showed a decrease of 31% from 0.638 to 0.436 W/mK, which is hopeful for heat insulation in the buildings. Increasing of the firing temperature also affected their mechanical and physical properties. This study showed that the olive mill waste could be used as a pore maker in brick production. Copyright © 2016 Elsevier Ltd. All rights reserved.
Emissions of volatile organic compounds and particulate matter from small-scale peat fires
NASA Astrophysics Data System (ADS)
George, I. J.; Black, R.; Walker, J. T.; Hays, M. D.; Tabor, D.; Gullett, B.
2013-12-01
Air pollution emitted from peat fires can negatively impact regional air quality, visibility, climate, and human health. Peat fires can smolder over long periods of time and, therefore, can release significantly greater amounts of carbon into the atmosphere per unit area compared to burning of other types of biomass. However, few studies have characterized the gas and particulate emissions from peat burning. To assess the atmospheric impact of peat fires, particulate matter (PM) and volatile organic compounds (VOCs) were quantified from controlled small-scale peat fire experiments. Major carbon emissions (i.e. CO2, CO, methane and total hydrocarbons) were measured during the peat burn experiments. Speciated PM mass was also determined from the peat burns from filter and polyurethane foam samples. Whole air samples were taken in SUMMA canisters and analyzed by gas chromatography-mass spectrometry to measure 82 trace VOCs. Additional gaseous carbonyl species were measured by sampling with dinitrophenylhydrazine-coated cartridges and analyzed with high performance liquid chromatography. VOCs with highest observed concentrations measured from the peat burns were propylene, benzene, chloromethane and toluene. Gas-phase carbonyls with highest observed concentrations included acetaldehyde, formaldehyde and acetone. Emission factors of major pollutants will be compared with recommended values for peat and other biomass burning.
Determination of Ignitable Liquids in Fire Debris: Direct Analysis by Electronic Nose
Ferreiro-González, Marta; Barbero, Gerardo F.; Palma, Miguel; Ayuso, Jesús; Álvarez, José A.; Barroso, Carmelo G.
2016-01-01
Arsonists usually use an accelerant in order to start or accelerate a fire. The most widely used analytical method to determine the presence of such accelerants consists of a pre-concentration step of the ignitable liquid residues followed by chromatographic analysis. A rapid analytical method based on headspace-mass spectrometry electronic nose (E-Nose) has been developed for the analysis of Ignitable Liquid Residues (ILRs). The working conditions for the E-Nose analytical procedure were optimized by studying different fire debris samples. The optimized experimental variables were related to headspace generation, specifically, incubation temperature and incubation time. The optimal conditions were 115 °C and 10 min for these two parameters. Chemometric tools such as hierarchical cluster analysis (HCA) and linear discriminant analysis (LDA) were applied to the MS data (45–200 m/z) to establish the most suitable spectroscopic signals for the discrimination of several ignitable liquids. The optimized method was applied to a set of fire debris samples. In order to simulate post-burn samples several ignitable liquids (gasoline, diesel, citronella, kerosene, paraffin) were used to ignite different substrates (wood, cotton, cork, paper and paperboard). A full discrimination was obtained on using discriminant analysis. This method reported here can be considered as a green technique for fire debris analyses. PMID:27187407
Fire training in a virtual-reality environment
NASA Astrophysics Data System (ADS)
Freund, Eckhard; Rossmann, Jurgen; Bucken, Arno
2005-03-01
Although fire is very common in our daily environment - as a source of energy at home or as a tool in industry - most people cannot estimate the danger of a conflagration. Therefore it is important to train people in combating fire. Beneath training with propane simulators or real fires and real extinguishers, fire training can be performed in virtual reality, which means a pollution-free and fast way of training. In this paper we describe how to enhance a virtual-reality environment with a real-time fire simulation and visualisation in order to establish a realistic emergency-training system. The presented approach supports extinguishing of the virtual fire including recordable performance data as needed in teletraining environments. We will show how to get realistic impressions of fire using advanced particle-simulation and how to use the advantages of particles to trigger states in a modified cellular automata used for the simulation of fire-behaviour. Using particle systems that interact with cellular automata it is possible to simulate a developing, spreading fire and its reaction on different extinguishing agents like water, CO2 or oxygen. The methods proposed in this paper have been implemented and successfully tested on Cosimir, a commercial robot-and VR-simulation-system.
Seasonal and local differences in leaf litter flammability of six Mediterranean tree species.
Kauf, Zorica; Fangmeier, Andreas; Rosavec, Roman; Španjol, Željko
2015-03-01
One of the suggested management options for reducing fire danger is the selection of less flammable plant species. Nevertheless, vegetation flammability is both complex and dynamic, making identification of such species challenging. While large efforts have been made to connect plant traits to fire behavior, seasonal changes and within species variability of traits are often neglected. Currently, even the most sophisticated fire danger systems presume that intrinsic characteristics of leaf litter stay unchanged, and plant species flammability lists are often transferred from one area to another. In order to assess if these practices can be improved, we performed a study examining the relationship between morphological characteristics and flammability parameters of leaf litter, thereby taking into account seasonal and local variability. Litter from six Mediterranean tree species was sampled throughout the fire season from three different locations along a climate gradient. Samples were subjected to flammability testing involving an epiradiator operated at 400 °C surface temperature with 3 g sample weight. Specific leaf area, fuel moisture content, average area, and average mass of a single particle had significant influences on flammability parameters. Effects of sampling time and location were significant as well. Due to the standardized testing conditions, these effects could be attributed to changes in intrinsic characteristics of the material. As the aforementioned effects were inconsistent and species specific, these results may potentially limit the generalization of species flammability rankings. Further research is necessary in order to evaluate the importance of our findings for fire danger modeling.
NASA Astrophysics Data System (ADS)
Klesner, Catherine Elizabeth
Decorative, polychrome ceramics from Corinth, Greece, produced during the 8th-6th centuries B.C.E. are luxury goods that were widely traded throughout Greece and the Mediterranean. The decorated ceramics were produced in a variety of shapes, including aryballos, alabastron, and olpe. They were decorated with slip-glazes in distinctive white, black, red, yellow, and purple colors, and in a variety of surface finishes, matte, semi-matte and glossy. Artisans in Corinthian workshops experimented to change the colors of the slips by varying the type and amount of iron-rich raw materials. They also varied the composition of the clay used as a binder and the amount of flux used as a sintering aid to promote glass formation. This research reconstructs the technology used by the Corinthian craftsmen to produce the Archaic polychrome ceramics, and shows how these technologies differed from the production of better known, more prestigious Athenian black-figure and red-figure ceramics. Through microstructural examination of archaeological samples and replication experiments, this thesis proposes that the purple iron oxide pigment is the result of acid treatment and oxidation of iron metal. The firing temperature range of the Corinthian polychrome ceramics was determined experimentally to be 925-1025°C, which is higher than previously reported and similar to that reported for Corinthian transport amphoras. The firing range is higher by 50-150°C than the Athenian black-figure and red-figure ceramics. Samples of Corinthian polychrome and Athenian black-figure ceramics from the Marie Farnsworth collection at the University of Arizona were tested and compared to Corinthian clay collections. Analytical techniques included Fourier-transform infrared spectroscopy (FTIR), scanning-electron microscopy with energy-dispersive spectroscopy (SEM-EDS), micro-Raman spectroscopy, and wavelength-dispersive electron microprobe (EPMA with BSE-SEM).
NASA Astrophysics Data System (ADS)
Bruni, Silvia; Guglielmi, Vittoria; Della Foglia, Elena; Castoldi, Marina; Bagnasco Gianni, Giovanna
2018-02-01
A study is presented based on the use of entirely non-destructive spectroscopic techniques to analyze the chemical composition of the painted surface layer of archaeological pottery. This study aims to define both the raw materials and the working technology of ancient potters. Energy-dispersive X-ray analysis, micro-Raman spectroscopy, visible and near infrared (NIR) diffuse reflection spectroscopy and external reflection Fourier-transform infrared (FTIR) spectroscopy were applied to matt-painted bichrome pottery sherds (VIII-VII century B.C.) from the site of Incoronata near Metaponto in southern Italy. Two different raw materials, ochre and iron-rich clay, were recognized for the red decoration, while the dark areas resulted to have been obtained by the so-called manganese black technique. In any case, it was demonstrated that the decoration was applied before firing, in spite of its sometimes grainy aspect that could suggest a post-firing application. For the samples with a more sophisticated decorative pattern a red/black/white polychromy was recognized, as the lighter areas correspond to an ;intentional white; obtained by the firing of a calcium-rich clay. Reflection spectroscopy in the visible-NIR and mid-IR as well as micro-Raman spectroscopy were then employed to characterize the decoration of an intact ceramic urn from the Etruscan town of Chiusi, evidencing a post-firing painting based on the use of red ochre, carbon black and lime, possibly imitating the ;fresco; technique used in wall paintings.
Development of fire shutters based on numerical optimizations
NASA Astrophysics Data System (ADS)
Novak, Ondrej; Kulhavy, Petr; Martinec, Tomas; Petru, Michal; Srb, Pavel
2018-06-01
This article deals with a prototype concept, real experiment and numerical simulation of a layered industrial fire shutter, based on some new insulating composite materials. The real fire shutter has been developed and optimized in laboratory and subsequently tested in the certified test room. A simulation of whole concept has been carried out as the non-premixed combustion process in the commercial final volume sw Pyrosim. Model of the combustion based on a stoichiometric defined mixture of gas and the tested layered samples showed good conformity with experimental results - i.e. thermal distribution inside and heat release rate that has gone through the sample.
Robert E. Keane
2013-01-01
Wildland fuelbeds are exceptionally complex, consisting of diverse particles of many sizes, types and shapes with abundances and properties that are highly variable in time and space. This complexity makes it difficult to accurately describe, classify, sample and map fuels for wildland fire research and management. As a result, many fire behaviour and effects software...
Spatial interpolation and simulation of post-burn duff thickness after prescribed fire
Peter R. Robichaud; S. M. Miller
1999-01-01
Prescribed fire is used as a site treatment after timber harvesting. These fires result in spatial patterns with some portions consuming all of the forest floor material (duff) and others consuming little. Prior to the burn, spatial sampling of duff thickness and duff water content can be used to generate geostatistical spatial simulations of these characteristics....
John N. Rinne; Codey D. Carter
2008-01-01
Summer 2002 was a season of markedly increased wildfire in the southwestern United States. Four fires affected landscapes that encompassed watersheds and streams containing fishes. Streams affected in three of the four fires were sampled for multiple factors, including fishes, to delineate the impact of fires on aquatic ecosystems in the -Southwest. All fishes were...
Long-term effects of fire severity on oak–conifer dynamics in the southern Cascades
Matthew I. Cocking; J. Morgan Varner; Eric E. Knapp
2014-01-01
We studied vegetation composition and structure in a mixed coniferâoak ecosystem across a range of fire severity 10 years following wildfire. Sample plots centered on focal California black oaks (Quercus kelloggii) were established to evaluate oak and neighboring tree and shrub recovery across a gradient of fire severity in the southern Cascade...
Forest fuel characterization using direct sampling in forest plantations
Eva Reyna Esmeralda Díaz García; Marco Aurelio González Tagle; Javier Jiménez Pérez; Eduardo JavierTreviño Garza; Diana Yemilet Ávila Flores
2013-01-01
One of the essential elements for a fire to occur is the flammable material. This is defined as the total biomass that has the ability to ignite and burn when exposed to a heat source. Fuel characterization in Mexican forest ecosystems is very scarce. However, this information is very important for estimating flammability and forest fire risk, fire behavior,...
The effects of prescribed fires on nutrient pools, soil-organisms, and vegetation patch dynamics were studied in three semi-arid mallee shrublands in western New South Wales. Repeated sampling of surface soil strata (0-2 and 2-4 cm) was undertaken at strategic times (immediately ...
Photo Series for Estimating Post-Hurricane Residues and Fire Behavior in Southern Pine
Dale D. Wade; James K. Forbus; James M. Saveland
1993-01-01
Following Hurricane Hugo, fuels were sampled on nine 2-acre blocks which were then burned during the spring wildfire season. The study was superimposed on dormant-season fire-interval research plots established in 1958 on the Francis Marion National Forest near Charleston, SC. Photographs of preburn fuel loads, fire behavior, and postburn fuel loads were taken to...
González-Martínez, Santiago C.; Navascués, Miguel; Burgarella, Concetta; Mosca, Elena; Lorenzo, Zaida; Zabal-Aguirre, Mario; Vendramin, Giovanni G.; Verdú, Miguel; Pausas, Juli G.
2017-01-01
Background and Aims The recurrence of wildfires is predicted to increase due to global climate change, resulting in severe impacts on biodiversity and ecosystem functioning. Recurrent fires can drive plant adaptation and reduce genetic diversity; however, the underlying population genetic processes have not been studied in detail. In this study, the neutral and adaptive evolutionary effects of contrasting fire regimes were examined in the keystone tree species Pinus halepensis Mill. (Aleppo pine), a fire-adapted conifer. The genetic diversity, demographic history and spatial genetic structure were assessed at local (within-population) and regional scales for populations exposed to different crown fire frequencies. Methods Eight natural P. halepensis stands were sampled in the east of the Iberian Peninsula, five of them in a region exposed to frequent crown fires (HiFi) and three of them in an adjacent region with a low frequency of crown fires (LoFi). Samples were genotyped at nine neutral simple sequence repeats (SSRs) and at 251 single nucleotide polymorphisms (SNPs) from coding regions, some of them potentially important for fire adaptation. Key Results Fire regime had no effects on genetic diversity or demographic history. Three high-differentiation outlier SNPs were identified between HiFi and LoFi stands, suggesting fire-related selection at the regional scale. At the local scale, fine-scale spatial genetic structure (SGS) was overall weak as expected for a wind-pollinated and wind-dispersed tree species. HiFi stands displayed a stronger SGS than LoFi stands at SNPs, which probably reflected the simultaneous post-fire recruitment of co-dispersed related seeds. SNPs with exceptionally strong SGS, a proxy for microenvironmental selection, were only reliably identified under the HiFi regime. Conclusions An increasing fire frequency as predicted due to global change can promote increased SGS with stronger family structures and alter natural selection in P. halepensis and in plants with similar life history traits. PMID:28159988
NASA Astrophysics Data System (ADS)
Waigl, C.; Stuefer, M.; Prakash, A.
2013-12-01
Wildfire is the main disturbance regime of the boreal forest ecosystem, a region acutely sensitive to climate change. Large fires impact the carbon cycle, permafrost, and air quality on a regional and even hemispheric scale. Because of their significance as a hazard to human health and economic activity, monitoring wildfires is relevant not only to science but also to government agencies. The goal of this study is to develop pathways towards a near real-time assessment of fire characteristics in the boreal zones of Alaska based on satellite remote sensing data. We map the location of active burn areas and derive fire parameters such as fire temperature, intensity, stage (smoldering or flaming), emission injection points, carbon consumed, and energy released. For monitoring wildfires in the sub-arctic region, we benefit from the high temporal resolution of data (as high as 8 images a day) from MODIS on the Aqua and Terra platforms and VIIRS on NPP/Suomi, downlinked and processed to level 1 by the Geographic Information Network of Alaska at the University of Alaska Fairbanks. To transcend the low spatial resolution of these sensors, a sub-pixel analysis is carried out. By applying techniques from Bayesian inverse modeling to Dozier's two-component approach, uncertainties and sensitivity of the retrieved fire temperatures and fractional pixel areas to background temperature and atmospheric factors are assessed. A set of test cases - large fires from the 2004 to 2013 fire seasons complemented by a selection of smaller burns at the lower end of the MODIS detection threshold - is used to evaluate the methodology. While the VIIRS principal fire detection band M13 (centered at 4.05 μm, similar to MODIS bands 21 and 22 at 3.959 μm) does not usually saturate for Alaskan wildfire areas, the thermal IR band M15 (10.763 μm, comparable to MODIS band 31 at 11.03 μm) indeed saturates for a percentage, though not all, of the fire pixels of intense burns. As this limits the application of the classical version of Dozier's model for this particular combination to lower intensity and smaller fires, or smaller fractional fire areas, other VIIRS band combinations are evaluated as well. Furthermore, the higher spatial resolution of the VIIRS sensor compared to MODIS and its constant along-scan resolution DNB (day/night band) dataset provide additional options for fire mapping, detection and quantification. Higher spatial resolution satellite-borne remote sensing data is used to validate the pixel and sub-pixel level analysis and to assess lower detection thresholds. For each sample fire, moderate-resolution imagery is paired with data from the ASTER instrument (simultaneous with MODIS data on the Terra platform) and/or Landsat scenes acquired in close temporal proximity. To complement the satellite-borne imagery, aerial surveys using a FLIR thermal imaging camera with a broadband TIR sensor provide additional ground truthing and a validation of fire location and background temperature.
Alpert, Hillel R; Christiani, David C; Orav, E John; Dockery, Douglas W; Connolly, Gregory N
2014-04-01
We evaluated the Massachusetts Fire Safe Cigarette Law's (FSCL's) effectiveness in preventing residential fires. We examined unintentional residential fires reported to the Massachusetts Fire Incident Reporting System from 2004 to 2010. We analyzed FSCL effect on the likelihood of cigarette- versus noncigarette-caused fires and effect modification by fire scenario factors by using an interrupted time series regression model. We analyzed the effect of FSCL on monthly fire rates with Poisson regression. Cigarettes caused 1629 unintentional residential fires during the study period. The FSCL was associated with a 28% (95% confidence interval = 12%, 41%) reduction in the odds of cigarette- versus noncigarette-caused fires, although not in analyses restricted to casualty fires, with smaller sample size. The largest reductions were among fires in which human factors were involved; that were first ignited on furniture, bedding, or soft goods; that occurred in living areas; or that occurred in the summer or winter. The FSCL appears to have decreased the likelihood of cigarette-caused residential fires, particularly in scenarios for which the ignition propensity standard was developed. Current standards should be adopted, and the need for strengthening should be considered.
Christiani, David C.; Orav, E. John; Dockery, Douglas W.; Connolly, Gregory N.
2014-01-01
Objectives. We evaluated the Massachusetts Fire Safe Cigarette Law’s (FSCL’s) effectiveness in preventing residential fires. Methods. We examined unintentional residential fires reported to the Massachusetts Fire Incident Reporting System from 2004 to 2010. We analyzed FSCL effect on the likelihood of cigarette- versus noncigarette-caused fires and effect modification by fire scenario factors by using an interrupted time series regression model. We analyzed the effect of FSCL on monthly fire rates with Poisson regression. Results. Cigarettes caused 1629 unintentional residential fires during the study period. The FSCL was associated with a 28% (95% confidence interval = 12%, 41%) reduction in the odds of cigarette- versus noncigarette-caused fires, although not in analyses restricted to casualty fires, with smaller sample size. The largest reductions were among fires in which human factors were involved; that were first ignited on furniture, bedding, or soft goods; that occurred in living areas; or that occurred in the summer or winter. Conclusions. The FSCL appears to have decreased the likelihood of cigarette-caused residential fires, particularly in scenarios for which the ignition propensity standard was developed. Current standards should be adopted, and the need for strengthening should be considered. PMID:24524537
10 CFR 5.215 - Membership practices of certain organizations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Section 5.215 Energy NUCLEAR REGULATORY COMMISSION NONDISCRIMINATION ON THE BASIS OF SEX IN EDUCATION... Scouts, Boy Scouts, and Camp Fire Girls. These Title IX regulations do not apply to the membership...), the Girl Scouts, the Boy Scouts, and Camp Fire Girls. (c) Voluntary youth service organizations. These...
10 CFR 5.215 - Membership practices of certain organizations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Section 5.215 Energy NUCLEAR REGULATORY COMMISSION NONDISCRIMINATION ON THE BASIS OF SEX IN EDUCATION... Scouts, Boy Scouts, and Camp Fire Girls. These Title IX regulations do not apply to the membership...), the Girl Scouts, the Boy Scouts, and Camp Fire Girls. (c) Voluntary youth service organizations. These...
10 CFR 5.215 - Membership practices of certain organizations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Section 5.215 Energy NUCLEAR REGULATORY COMMISSION NONDISCRIMINATION ON THE BASIS OF SEX IN EDUCATION... Scouts, Boy Scouts, and Camp Fire Girls. These Title IX regulations do not apply to the membership...), the Girl Scouts, the Boy Scouts, and Camp Fire Girls. (c) Voluntary youth service organizations. These...
10 CFR 5.215 - Membership practices of certain organizations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Section 5.215 Energy NUCLEAR REGULATORY COMMISSION NONDISCRIMINATION ON THE BASIS OF SEX IN EDUCATION... Scouts, Boy Scouts, and Camp Fire Girls. These Title IX regulations do not apply to the membership...), the Girl Scouts, the Boy Scouts, and Camp Fire Girls. (c) Voluntary youth service organizations. These...
10 CFR 5.215 - Membership practices of certain organizations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Section 5.215 Energy NUCLEAR REGULATORY COMMISSION NONDISCRIMINATION ON THE BASIS OF SEX IN EDUCATION... Scouts, Boy Scouts, and Camp Fire Girls. These Title IX regulations do not apply to the membership...), the Girl Scouts, the Boy Scouts, and Camp Fire Girls. (c) Voluntary youth service organizations. These...
Coal-Fired Boilers at Navy Bases, Navy Energy Guidance Study, Phase II and III.
1979-05-01
several sizes were performed. Central plants containing four equal-sized boilers and central flue gas desulfurization facilities were shown to be less...Conceptual design and parametric cost studies of steam and power generation systems using coal-fired stoker boilers and stack gas scrubbers in
10 CFR 503.25 - Public interest.
Code of Federal Regulations, 2010 CFR
2010-01-01
... OF ENERGY (CONTINUED) ALTERNATE FUELS NEW FACILITIES Temporary Exemptions for New Facilities § 503.25..., during the construction of an alternate-fuel fired unit, the petitioner may substitute, in lieu of the... during the construction of an alternate fuel fired unit to be owned or operated by the petitioner; and (2...
Engle, Mark A.; Olea, Ricardo A.; O'Keefe, Jennifer M. K.; Hower, James C.; Geboy, Nicholas J.
2013-01-01
Coal fires occur in nature spontaneously, contribute to increases in greenhouse gases, and emit atmospheric toxicants. Increasing interest in quantifying coal fire emissions has resulted in the adaptation and development of specialized approaches and adoption of numerical modeling techniques. Overview of these methods for direct estimation of diffuse gas emissions from coal fires is presented in this paper. Here we take advantage of stochastic Gaussian simulation to interpolate CO2 fluxes measured using a dynamic closed chamber at the Ruth Mullins coal fire in Perry County, Kentucky. This approach allows for preparing a map of diffuse gas emissions, one of the two primary ways that gases emanate from coal fires, and establishing the reliability of the study both locally and for the entire fire. Future research directions include continuous and automated sampling to improve quantification of gaseous coal fire emissions.
Pyrodiversity promotes avian diversity over the decade following forest fire.
Tingley, Morgan W; Ruiz-Gutiérrez, Viviana; Wilkerson, Robert L; Howell, Christine A; Siegel, Rodney B
2016-10-12
An emerging hypothesis in fire ecology is that pyrodiversity increases species diversity. We test whether pyrodiversity-defined as the standard deviation of fire severity-increases avian biodiversity at two spatial scales, and whether and how this relationship may change in the decade following fire. We use a dynamic Bayesian community model applied to a multi-year dataset of bird surveys at 1106 points sampled across 97 fires in montane California. Our results provide strong support for a positive relationship between pyrodiversity and bird diversity. This relationship interacts with time since fire, with pyrodiversity having a greater effect on biodiversity at 10 years post-fire than at 1 year post-fire. Immediately after fires, patches of differing burn severities hold similar bird communities, but over the ensuing decade, bird assemblages within patches of contrasting severities differentiate. When evaluated at the scale of individual fires, fires with a greater heterogeneity of burn severities hold substantially more species. High spatial heterogeneity in severity, sometimes called 'mixed-severity fire', is a natural part of wildfire regimes in western North America, but may be jeopardized by climate change and a legacy of fire suppression. Forest management that encourages mixed-severity fire may be critical for sustaining biodiversity across fire-prone landscapes. © 2016 The Author(s).
Pyrodiversity promotes avian diversity over the decade following forest fire
Ruiz-Gutiérrez, Viviana; Wilkerson, Robert L.; Howell, Christine A.; Siegel, Rodney B.
2016-01-01
An emerging hypothesis in fire ecology is that pyrodiversity increases species diversity. We test whether pyrodiversity—defined as the standard deviation of fire severity—increases avian biodiversity at two spatial scales, and whether and how this relationship may change in the decade following fire. We use a dynamic Bayesian community model applied to a multi-year dataset of bird surveys at 1106 points sampled across 97 fires in montane California. Our results provide strong support for a positive relationship between pyrodiversity and bird diversity. This relationship interacts with time since fire, with pyrodiversity having a greater effect on biodiversity at 10 years post-fire than at 1 year post-fire. Immediately after fires, patches of differing burn severities hold similar bird communities, but over the ensuing decade, bird assemblages within patches of contrasting severities differentiate. When evaluated at the scale of individual fires, fires with a greater heterogeneity of burn severities hold substantially more species. High spatial heterogeneity in severity, sometimes called ‘mixed-severity fire', is a natural part of wildfire regimes in western North America, but may be jeopardized by climate change and a legacy of fire suppression. Forest management that encourages mixed-severity fire may be critical for sustaining biodiversity across fire-prone landscapes. PMID:27708152
NASA Astrophysics Data System (ADS)
Belcher, Claire M.; Hadden, Rory; McElwain, Jennifer C.; Rein, Guillermo
2010-05-01
Fire is a natural process integral to ecosystems at a wide range of temporal and spatial scales and is a key driver of change in the Earth system. Fire has been a major influence on Earth's systems since the Carboniferous. Whilst, climate is considered the ultimate control on global vegetation, fire is now known to play a key role in determining vegetation structure and composition, such that many of the world's ecosystems can be considered fire-dependant. Products of fire include chars, soots and aromatic hydrocarbon species all of which can be traced in ancient through to modern sediments. Atmospheric oxygen has played a key role in the development of life on Earth, with the rise of oxygen in the Precambrian being closely linked to biological evolution. Variations in the concentration of atmospheric oxygen throughout the Phanerozoic are predicted from models based on geochemical cycling of carbon and sulphur. Such models predict that low atmospheric oxygen concentrations prevailed in the Mesozoic (251-65ma) and have been hypothesised to be the primary driver of at least two of the ‘big five' mass extinction events in the Phanerozoic. Here we assess the levels of atmospheric oxygen required to ignite a fire and infer the likely levels of atmospheric oxygen to support smouldering combustion. Smouldering fire dynamics and its effects on ecosystems are very different from flaming fires. Smouldering fires propagate slowly, are usually low in temperature and represent a flameless form of combustion. These fires creep through organic layers of forest ground and peat lands and are responsible for a large fraction of the total biomass consumed in wildfires globally and are also a major contributor of carbon dioxide to the atmosphere. Once ignited, they can persist for long periods of time (months, years) spreading over very extensive areas of forest and deep into soil. Smouldering fires are therefore, the oldest continuously burning fires on Earth. We have combined expertise from both the Earth science and fire engineering disciplines to develop realistic ignition mechanisms and measurements of fire propagation within different levels of atmospheric oxygen. We present data from experimental burns run in the fully controlled and realistic atmospheric environment of the UCD PÉAC facility. The burns are designed to develop our understanding of ignition of fires in the natural world. We have studied ignition and propagation of fire in peat, a natural and highly flammable substance. Peat samples of approximately 100mm by 100mm in cross section and 50mm in depth were exposed to an ignition source (~100W of electric power) for 30 minutes. Thermocouples were placed throughout the sample to measure temperature changes during the initial 30 minute ignition phase and in order to observe ignition of the peat, intensity of combustion and spread of the smouldering front within the different atmospheric oxygen settings. We show that ignition and propagation of smouldering in peat does not occur below 16% atmospheric oxygen and that smouldering combustion continues for long periods (~4 hours in the size sample used) at 18% atmospheric oxygen and above. This suggests that atmospheric levels above 16% atmospheric are required to allow ignition and propagation of smouldering fires and that frequent occurrences of wildfires might only be expected in the geological past when atmospheric levels were above 18% oxygen. Fires play an important role in Earth's biogeochemical cycles; this work suggests that fire feedbacks into the Earth system would likely have been suppressed during periods of low atmospheric oxygen.
Duvane, Jossias A; Jorge, Tiago F; Maquia, Ivete; Ribeiro, Natasha; Ribeiro-Barros, Ana I F; António, Carla
2017-01-01
Miombo and Mopane are ecological and economic important woodlands from Africa, highly affected by a combination of climate change factors, and anthropogenic fires. Although most species of these ecosystems are fire tolerant, the mechanisms that lead to adaptive responses (metabolic reconfiguration) are unknown. In this context, the aim of this study was to characterize the primary metabolite composition of typical legume trees from these ecosystems, namely, Brachystegia boehmii (Miombo) and Colophospermum mopane (Mopane) subjected to different fire regimes. Fresh leaves from each species were collected in management units and landscapes across varied fire frequencies in the Niassa National Reserve (NNR) and Limpopo National Park (LNP) in Mozambique. Primary metabolites were extracted and analyzed with a well-established gas chromatography time-of-flight mass spectrometry metabolomics platform (GC-TOF-MS). In B. boehmii , 39 primary metabolites were identified from which seven amino acids, two organic acids and two sugars increased significantly, whereas in C. mopane , 41 primary metabolites were identified from which eight amino acids, one sugar and two organic acids significantly increased with increasing fire frequency. The observed changes in the pool of metabolites of C. mopane might be related to high glycolytic and tricarboxylic acid (TCA) rate, which provided increased levels of amino acids and energy yield. In B. boehmii , the high levels of amino acids might be due to inhibition of protein biosynthesis. The osmoprotectant and reactive oxygen species (ROS) scavenging properties of accumulated metabolites in parallel with a high-energy yield might support plants survival under fire stress.
Urban fire risk control: House design, upgrading and replanning
Mbuya, Elinorata Celestine
2018-01-01
Urbanisation leads to house densification, a phenomenon experienced in both planned and unplanned settlements in cities in developing countries. Such densification limits fire brigade access into settlements, thereby aggravating fire disaster risks. In this article, we assess the fire exposure and risks in residences in informal areas of Mchikichini ward, in Dar es Salaam City, Tanzania. We rely on interviews of residents and government officials to obtain background on the occurrence and causes of fire accidents, policy provisions and regulations, and experiences with fire outbreaks and coping strategies, as well as on observations and measurements of house transformations, spatial quality and indoor real life. Our findings suggest that fire risks arise from both inappropriate structural characteristics and unsound behavioural practices. This includes unsafe electric practices by residents, poor capacity of residents to fight fires once started, limited access to structures by firefighting equipment because of flouting of planning regulations and inadequate awareness of local government leaders of the magnitude of fire risks. Potential changes to reduce fire risks in the settlement include the installation of firefighting systems, restriction of cooking to designated spaces, use of safer cooking energy sources and lighting means, improvements of vehicle access routes to neighbourhoods, capacity building at the grass root level and the establishment of community-based fire risk management.
Synchronization in neural nets
NASA Technical Reports Server (NTRS)
Vidal, Jacques J.; Haggerty, John
1988-01-01
The paper presents an artificial neural network concept (the Synchronizable Oscillator Networks) where the instants of individual firings in the form of point processes constitute the only form of information transmitted between joining neurons. In the model, neurons fire spontaneously and regularly in the absence of perturbation. When interaction is present, the scheduled firings are advanced or delayed by the firing of neighboring neurons. Networks of such neurons become global oscillators which exhibit multiple synchronizing attractors. From arbitrary initial states, energy minimization learning procedures can make the network converge to oscillatory modes that satisfy multi-dimensional constraints. Such networks can directly represent routing and scheduling problems that consist of ordering sequences of events.
A combustion model of vegetation burning in "Tiger" fire propagation tool
NASA Astrophysics Data System (ADS)
Giannino, F.; Ascoli, D.; Sirignano, M.; Mazzoleni, S.; Russo, L.; Rego, F.
2017-11-01
In this paper, we propose a semi-physical model for the burning of vegetation in a wildland fire. The main physical-chemical processes involved in fire spreading are modelled through a set of ordinary differential equations, which describe the combustion process as linearly related to the consumption of fuel. The water evaporation process from leaves and wood is also considered. Mass and energy balance equations are written for fuel (leaves and wood) assuming that combustion process is homogeneous in space. The model is developed with the final aim of simulating large-scale wildland fires which spread on heterogeneous landscape while keeping the computation cost very low.
NASA Technical Reports Server (NTRS)
Chatfield, Robert B.; Andreae, Meinrat O.
2016-01-01
Previous studies of emission factors from biomass burning are prone to large errors since they ignore the interplay of mixing and varying pre-fire background CO2 levels. Such complications severely affected our studies of 446 forest fire plume samples measured in the Western US by the science teams of NASA's SEAC4RS and ARCTAS airborne missions. Consequently we propose a Mixed Effects Regression Emission Technique (MERET) to check techniques like the Normalized Emission Ratio Method (NERM), where use of sequential observations cannot disentangle emissions and mixing. We also evaluate a simpler "consensus" technique. All techniques relate emissions to fuel burned using C(burn) = delta C(tot) added to the fire plume, where C(tot) approximately equals (CO2 = CO). Mixed-effects regression can estimate pre-fire background values of C(tot) (indexed by observation j) simultaneously with emissions factors indexed by individual species i, delta, epsilon lambda tau alpha-x(sub I)/C(sub burn))I,j. MERET and "consensus" require more than emissions indicators. Our studies excluded samples where exogenous CO or CH4 might have been fed into a fire plume, mimicking emission. We sought to let the data on 13 gases and particulate properties suggest clusters of variables and plume types, using non-negative matrix factorization (NMF). While samples were mixtures, the NMF unmixing suggested purer burn types. Particulate properties (b scant, b abs, SSA, AAE) and gas-phase emissions were interrelated. Finally, we sought a simple categorization useful for modeling ozone production in plumes. Two kinds of fires produced high ozone: those with large fuel nitrogen as evidenced by remnant CH3CN in the plumes, and also those from very intense large burns. Fire types with optimal ratios of delta-NOy/delta- HCHO associate with the highest additional ozone per unit Cburn, Perhaps these plumes exhibit limited NOx binding to reactive organics. Perhaps these plumes exhibit limited NOx binding to reactive organics
NASA Technical Reports Server (NTRS)
Chatfield, Robert B.; Andreae, Meinrat O.
2015-01-01
Previous studies of emission factors from biomass burning are prone to large errors since they ignore the interplay of mixing and varying pre-fire background CO2 levels. Such complications severely affected our studies of 446 forest fire plume samples measured in the Western US by the science teams of NASA's SEAC4RS and ARCTAS airborne missions. Consequently we propose a Mixed Effects Regression Emission Technique (MERET) to check techniques like the Normalized Emission Ratio Method (NERM), where use of sequential observations cannot disentangle emissions and mixing. We also evaluate a simpler "consensus" technique. All techniques relate emissions to fuel burned using C(sub burn) = delta C(sub tot) added to the fire plume, where C(sub tot) approximately equals (CO2 + CO). Mixed-effects regression can estimate pre-fire background values of Ctot (indexed by observation j) simultaneously with emissions factors indexed by individual species i, delta epsilon lambda tau alpha-x(sub i)/(C(sub burn))i,j., MERET and "consensus" require more than two emissions indicators. Our studies excluded samples where exogenous CO or CH4 might have been fed into a fire plume, mimicking emission. We sought to let the data on 13 gases and particulate properties suggest clusters of variables and plume types, using non-negative matrix factorization (NMF). While samples were mixtures, the NMF unmixing suggested purer burn types. Particulate properties (bscat, babs, SSA, AAE) and gas-phase emissions were interrelated. Finally, we sought a simple categorization useful for modeling ozone production in plumes. Two kinds of fires produced high ozone: those with large fuel nitrogen as evidenced by remnant CH3CN in the plumes, and also those from very intense large burns. Fire types with optimal ratios of delta-NOy/delta- HCHO associate with the highest additional ozone per unit Cburn, Perhaps these plumes exhibit limited NOx binding to reactive organics. Perhaps these plumes exhibit limited NOx binding to reactive organics.
Experiments with the Skylab fire detectors in zero gravity
NASA Technical Reports Server (NTRS)
Linford, R. M. F.
1972-01-01
The Skylab fire detector was evaluated in a zero gravity environment. To conduct the test, small samples of spacecraft materials were ignited in a 5 psi oxygen-rich atmosphere inside a combustion chamber. The chamber free-floated in the cabin of a C-135 aircraft, as the aircraft executed a Keplerian parabola. Up to 10 seconds of zero-gravity combustion were achieved. The Skylab fire-detector tubes viewed the flames from a simulated distance of 3m, and color movies were taken to record the nature of the fire. The experiments established the unique form of zero-gravity fires for a wide range of materials. From the tube-output data, the alarm threshold and detector time constant were verified for the Skylab Fire Detection System.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Fang; Lawrence, David M.; Bond-Lamberty, Ben
Fire is a global phenomenon and tightly interacts with the biosphere and climate. This study provides the first quantitative assessment of fire’s influence on the global land air temperature during the 20th century through its impact on terrestrial ecosystems. We quantify the impact of fire by comparing 20th century fire-on and fire-off simulations with the Community Earth System Model (CESM) as the model platform. Here, results show that fire-induced changes in terrestrial ecosystems increased global land surface air temperature by 0.04 °C. Such changes significantly warmed the tropical savannas and southern Asia mainly by reducing latent heat flux, but cooledmore » Southeast China by enhancing the East Asian winter monsoon. 20% of the early 20th century global land warming can be attributed to fire-induced changes in terrestrial ecosystems, providing a new mechanism for explaining the poorly-understood climate change.« less
NASA Astrophysics Data System (ADS)
Sparks, A. M.; Smith, A. M.; Kolden, C.; Apostol, K. G.; Boschetti, L.
2014-12-01
Fire is a common disturbance in forested ecosystems in the western U.S. and can be responsible for long-term impacts on vegetation and soil. An improved understanding of how ecosystems recover after fire is necessary so that land managers can plan for and mitigate the effects of these disturbances. Although several studies have attempted to link fire intensity with severity, direct links between spectral indices of severity and key physiological changes in vegetation are not well understood. We conducted an assessment of how two western conifer species respond to four fire radiative energy treatments, with spectra acquired pre- and up to a month post-burn. After transforming the spectral data into Landsat 8 equivalent reflectance, burn severity indices commonly used in the remote sensing community were compared to concurrent physiological measurements including gas exchange and photosynthetic rate. Preliminary results indicate significant relationships between several fire severity indices and physiological responses measured in the conifer seedlings.
Li, Fang; Lawrence, David M.; Bond-Lamberty, Ben
2017-04-03
Fire is a global phenomenon and tightly interacts with the biosphere and climate. This study provides the first quantitative assessment of fire’s influence on the global land air temperature during the 20th century through its impact on terrestrial ecosystems. We quantify the impact of fire by comparing 20th century fire-on and fire-off simulations with the Community Earth System Model (CESM) as the model platform. Here, results show that fire-induced changes in terrestrial ecosystems increased global land surface air temperature by 0.04 °C. Such changes significantly warmed the tropical savannas and southern Asia mainly by reducing latent heat flux, but cooledmore » Southeast China by enhancing the East Asian winter monsoon. 20% of the early 20th century global land warming can be attributed to fire-induced changes in terrestrial ecosystems, providing a new mechanism for explaining the poorly-understood climate change.« less
Future CO2 emissions and electricity generation from proposed coal-fired power plants in India
NASA Astrophysics Data System (ADS)
Fofrich, R.; Shearer, C.; Davis, S. J.
2017-12-01
India represents a critical unknown in global projections of future CO2 emissions due to its growing population, industrializing economy, and large coal reserves. In this study, we assess existing and proposed construction of coal-fired power plants in India and evaluate their implications for future energy production and emissions in the country. In 2016, India had 369 coal-fired power plants under development totaling 243 gigawatts (GW) of generating capacity. These coal-fired power plants would increase India's coal-fired generating capacity by 123% and would exceed India's projected electricity demand. Therefore, India's current proposals for new coal-fired power plants would be forced to retire early or operate at very low capacity factors and/or would prevent India from meeting its goal of producing at least 40% of its power from renewable sources by 2030. In addition, future emissions from proposed coal-fired power plants would exceed India's climate commitment to reduce its 2005 emissions intensity 33% - 35% by 2030.
Environmental Perturbations Caused by the Impacts of Comets and Asteroids on Earth
NASA Technical Reports Server (NTRS)
Toon, Owen B.; Lawless, James G. (Technical Monitor)
1994-01-01
The extinction mechanisms proposed at the Cretaceous-Tertiary geological boundary are reviewed and related to the impact of asteroids or comets in general. For impact energies below 10(exp 4) Megatons (less than 6 x 10(exp 4) years; asteroid diameter less than 650 m), blast, earthquake, and fire may destroy local areas up to 10(exp 5) square m. Tidal waves could flood a kilometer inland over entire ocean basins. The energy range from 105 to 106 Megatons (less than 2 x 10(exp 6) years; asteroid diameter less than 3 km) is transitional. Dust lifted, sulfur released from within impacting asteroids, and soot from fires started by comets can produce climatologically significant optical depths of 10. At energies beyond 10(exp 7) Megatons, blast and earthquake damage is regional (10(exp 6) square cm). Tsunami cresting to 100 m and flooding 20 km inland will sweep the coastal zones of the world's oceans. Fires will be set globally. Light levels may drop so low from the smoke, dust and sulfate that vision is not possible. At energies approaching 10(exp 9) Megatons the ocean surface waters may be acidified by sulfur. The combination of these effects would be devastating.
NASA Astrophysics Data System (ADS)
Jiang, Y.; Rastetter, E.; Shaver, G. R.; Rocha, A. V.
2012-12-01
In Alaska, fire disturbance is a major component influencing the soil water and energy balance in both tundra and boreal forest ecosystems. Fire-caused changes in soil environment further affect both above- and below-ground carbon cycles depending on different fire severities. Understanding the effects of fire disturbance on soil thermal change requires implicit modeling work on the post-fire soil thawing and freezing processes. In this study, we model the soil temperature profiles in multiple burned and non-burned sites using a well-developed soil thermal model which fully couples soil water and heat transport. The subsequent change in carbon dynamics is analyzed based on site level observations and simulations from the Multiple Element Limitation (MEL) model. With comparison between burned and non-burned sites, we compare and contrast fire effects on soil thermal and carbon dynamics in continuous permafrost (Anaktuvik fire in north slope), discontinuous permafrost (Erickson Creek fire at Hess Creek) and non-permafrost zone (Delta Junction fire in interior Alaska). Then we check the post-fire recovery of soil temperature profiles at sites with different fire severities in both tundra and boreal forest fire areas. We further project the future changes in soil thermal and carbon dynamics using projected climate data from Scenarios Network for Alaska & Arctic Planning (SNAP). This study provides information to improve the understanding of fire disturbance on soil thermal and carbon dynamics and the consequent response under a warming climate.
The effects of fire temperatures on water soluble heavy metals.
NASA Astrophysics Data System (ADS)
Pereira, P.; Ubeda, X.; Martin, D. A.
2009-04-01
Fire ash are majority composed by base cations, however the mineralized organic matter, led also available to transport a higher quantity of heavy metals that potentially could increase a toxicity in soil and water resources. The amount availability of these elements depend on the environment were the fire took place, burning temperature and combusted tree specie. The soil and water contamination from fire ash has been neglected, because the majority of studies are focused on base cations dynamic. Our research, beside contemplate major elements, is focused in to study the behavior of heavy metals released from ash slurries created at several temperatures under laboratory environment, prescribed fires and wildland fires. The results presented in these communication are preliminary and study the presence of Aluminium (Al3+), Manganese (Mn2+), Iron (Fe2+) and Zinc (Zn2+) of ash slurries generated in laboratory environment at several temperatures (150°, 200°, 250°, 300°, 350°, 400°,450°, 500°, 550°C) from Quercus suber, Quercus robur, Pinus pinea and Pinus pinaster and from a low medium temperature prescribed fire in a forest dominated Quercus suber trees. We observed that ash produced at lower and medium temperatures (<300-400°C) released in water higher contents of Al3+ than unburned sample, especially in Quercus species and Mn2+ in Pinus ashes. Fe2+ and Zn2+ showed a reduced concentration in test solution in relation to unburned sample at all temperatures of exposition. In the results obtained from prescribed fire, we identify a higher release of Al3+ and a decrease of the remain elements. The solubilization of these elements are related with pH levels and ash calcite content, because their ability to capture ions in solution. Moreover, the amount and the type of ions released in relation to unburned sample vary in each specie. In this study Al3+ release is related with Quercus species and Mn2+ with Pinus species. Fire ashes can be an environmental problem, because at long term can increase soil acidity. After all base cations have being leached, pH values decrease, and the heavy metals remaining in the ash are easily transported with unknown impacts on soil and water resources. Research is needed in the study at long term of the effects of fire in metals accumulation in soil resources, and all these aspects will be discussed. Keywords: Fire ash, heavy metals, Quercus suber, Quercus robur, Pinus pinea, Pinus pinaster, prescribed fire, pH, Calcite
NASA Technical Reports Server (NTRS)
Williams, J. R.
1974-01-01
The conversion of fossil-fired power plants now burning oil or gas to burn coal is discussed along with the relaxation of air quality standards and the development of coal gasification processes to insure a continued supply of gas from coal. The location of oil fields, refining areas, natural gas fields, and pipelines in the U.S. is shown. The technologies of modern fossil-fired boilers and gas turbines are defined along with the new technologies of fluid-bed boilers and MHD generators.
Investigation of UF/sub 6/ behavior in a fire
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, W.R.
Reactions between UF/sub 6/ and combustible gases and the potential for UF/sub 6/-filled cylinders to rupture when exposed to fire are addressed. Although the absence of kinetic data prevents specific identification and quantification of the chemical species formed, potential reaction products resulting from the release of UF/sub 6/ into a fire include UF/sub 4/, UO/sub 2/F/sub 2/, HF, C, CF/sub 4/,COF/sub 2/, and short chain, fluorinated or partially fluorinated hydrocarbons. Such a release adds energy to a fire relative to normal combustion reactions. Time intervals to an assumed point of rupture for UF/sub 6/-filled cylinders exposed to fire are estimatedmore » conservatively. Several related studies are also summarized, including a test series in which small UF/sub 6/-filled cylinders were immersed in fire resulting in valve failures and explosive ruptures. It is concluded that all sizes of UF/sub 6/ cylinders currently in use may rupture within 30 minutes when totally immersed in a fire. For cylinders adjacent to fires, rupture of the larger cylinders appears much less likely.« less
Neural Energy Supply-Consumption Properties Based on Hodgkin-Huxley Model
2017-01-01
Electrical activity is the foundation of the neural system. Coding theories that describe neural electrical activity by the roles of action potential timing or frequency have been thoroughly studied. However, an alternative method to study coding questions is the energy method, which is more global and economical. In this study, we clearly defined and calculated neural energy supply and consumption based on the Hodgkin-Huxley model, during firing action potentials and subthreshold activities using ion-counting and power-integral model. Furthermore, we analyzed energy properties of each ion channel and found that, under the two circumstances, power synchronization of ion channels and energy utilization ratio have significant differences. This is particularly true of the energy utilization ratio, which can rise to above 100% during subthreshold activity, revealing an overdraft property of energy use. These findings demonstrate the distinct status of the energy properties during neuronal firings and subthreshold activities. Meanwhile, after introducing a synapse energy model, this research can be generalized to energy calculation of a neural network. This is potentially important for understanding the relationship between dynamical network activities and cognitive behaviors. PMID:28316842
NASA Astrophysics Data System (ADS)
Pastor, E.; Tarragó, D.; Planas, E.
2012-04-01
Wildfire theoretical modeling endeavors predicting fire behavior characteristics, such as the rate of spread, the flames geometry and the energy released by the fire front by applying the physics and the chemistry laws that govern fire phenomena. Its ultimate aim is to help fire managers to improve fire prevention and suppression and hence reducing damage to population and protecting ecosystems. WFDS is a 3D computational fluid dynamics (CFD) model of a fire-driven flow. It is particularly appropriate for predicting the fire behaviour burning through the wildland-urban interface, since it is able to predict the fire behaviour in the intermix of vegetative and structural fuels that comprise the wildland urban interface. This model is not suitable for operational fire management yet due to computational costs constrains, but given the fact that it is open-source and that it has a detailed description of the fuels and of the combustion and heat transfer mechanisms it is currently a suitable system for research purposes. In this paper we present the most important characteristics of the WFDS simulation tool in terms of the models implemented, the input information required and the outputs that the simulator gives useful for understanding fire phenomena. We briefly discuss its advantages and opportunities through some simulation exercises of Mediterranean ecosystems.
Condition of live fire-scarred ponderosa pine eleven years after removing partial cross-sections
Emily K. Heyerdahl; Steven J. McKay
2008-01-01
Our objective is to report mortality rates for ponderosa pine trees in Oregon ten to eleven years after removing a fire-scarred partial cross-section from them, and five years after an initial survey of post-sampling mortality. We surveyed 138 live trees from which we removed fire-scarred partial crosssections in 1994/95 and 387 similarly sized, unsampled neighbor...
Multicentury fire and forest histories at 19 sites in Utah and eastern Nevada
Emily K. Heyerdahl; Peter M. Brown; Stanley G. Kitchen; Marc H. Weber
2011-01-01
Our objective is to provide site-specific fire and forest histories from Utah and eastern Nevada that can be used for land management or additional research. We systematically sampled fire scars and tree-recruitment dates across broad gradients in elevation and forest type at 13 sites in Utah and 1 in eastern Nevada to characterize spatial and temporal variation in...
Predicting rate of fire spread (ROS) in Arizona oak chaparral: Field workbook
James R. Davis; John H. Dieterich
1976-01-01
To facilitate field use of the rate of fire spread equation used in Arizona oak chaparral, step-by-step instructions are presented in workbook form. Input data can be either measured or estimated from the tables and figures included; a sample computation form may be duplicated for field use. Solving the equation gives the land manager the guidelines for planning fire...
Kenneth L. Clark; Nicholas Skowronski; John Hom; Matthew Duveneck; Yude Pan; Stephen Van Tuyl; Jason Cole; Matthew Patterson; Stephen Maurer
2009-01-01
Our goal is to assist the New Jersey Forest Fire Service and federal wildland fire managers in the New Jersey Pine Barrens evaluate where and when to conduct hazardous fuel reduction treatments. We used remotely sensed LIDAR (Light Detection and Ranging System) data and field sampling to estimate fuel loads and consumption during prescribed fire treatments. This...
Hossack, B.R.; Corn, P.S.; Fagre, D.B.
2006-01-01
Wildfire is a potential threat to many species with narrow environmental tolerances like the Rocky Mountain tailed frog (Ascaphus montanus Mittleman and Myers, 1949), which inhabits a region where the frequency and intensity of wildfires are expected to increase. We compared pre- and post-fire counts of tadpoles in eight streams in northwestern Montana to determine the effects of wildfire on A. montanus. All streams were initially sampled in 2001, 2 years before four of them burned in a large wildfire, and were resampled during the 2 years following the fire. Counts of tadpoles were similar in the two groups of streams before the fire. After the fire, tadpoles were almost twice as abundant in unburned streams than in burned streams. The fire seemed to have the greatest negative effect on abundance of age-1 tadpoles, which was reflected in the greater variation in same-stream age-class structure compared with those in unburned streams. Despite the apparent effect on tadpoles, we do not expect the wildfire to be an extirpation threat to populations in the streams that we sampled. Studies spanning a chronosequence of fires, as well as in other areas, are needed to assess the effects of fires on streams with A. montanus and to determine the severity and persistence of these effects.
Alcañiz, M; Outeiro, L; Francos, M; Farguell, J; Úbeda, X
2016-12-01
This study examines the effects of a prescribed fire on soil chemical properties in the Montgrí Massif (Girona, Spain). The prescribed forest fire was conducted in 2006 to reduce understory vegetation and so prevent potential severe wildfires. Soil was sampled at a depth of 0-5cm at 42 sampling points on four separate occasions: prior to the event, immediately after, one year after and nine years after. The parameters studied were pH, electrical conductivity (EC), total carbon (C), total nitrogen (N), available phosphorus (P), potassium (K + ), calcium (Ca 2+ ) and magnesium (Mg 2+ ). All parameters (except pH) increased significantly immediately after the fire. One year after burning, some chemical parameters - namely, EC, available P and K + - had returned to their initial, or even lower, values; while others - pH and total C - continued to rise. Total N, Ca 2+ and Mg 2+ levels had fallen one year after the fire, but levels were still higher than those prior to the event. Nine years after the fire, pH, total C, total N and available P are significantly lower than pre-fire values and nutrients concentrations are now higher than at the outset but without statistical significance. The soil system, therefore, is still far from being recovered nine years later. Copyright © 2016 Elsevier B.V. All rights reserved.
Fire Signatures of Materials Used in Spacecraft Construction
NASA Technical Reports Server (NTRS)
Taylor, Christina
2003-01-01
The focus of my work this summer was fire safety, specifically determining fire signatures from the combustion of materials commonly found in the construction of spacecraft. This project was undertaken with the aim of addressing concerns for health and safety onboard spacecraft. Under certain conditions, burning electronics produce surprisingly large amounts of acrid smoke, release fine airborne particles and expel condensable aerosols. Similarly, some wire insulation and packing material evolves smoke when in contact with a hot surface. In the limited, enclosed space available on spacecraft, these combustion products may pose a nuisance at the very least - at worst, a hazard to health or equipment. There is also a concern for fire safety in early detection on spacecraft. Our goal for the summer was to determine the most effective methods to test the materials, develop a protocol for sampling, and generate samples for analysis. We restricted our testing to electronic components, packaging and insulation materials, and wire insulation materials.
Identifying persistent and characteristic features in firearm tool marks on cartridge cases
NASA Astrophysics Data System (ADS)
Ott, Daniel; Soons, Johannes; Thompson, Robert; Song, John
2017-12-01
Recent concerns about subjectivity in forensic firearm identification have motivated the development of algorithms to compare firearm tool marks that are imparted on ammunition and to generate quantitative measures of similarity. In this paper, we describe an algorithm that identifies impressed tool marks on a cartridge case that are both consistent between firings and contribute strongly to a surface similarity metric. The result is a representation of the tool mark topography that emphasizes both significant and persistent features across firings. This characteristic surface map is useful for understanding the variability and persistence of the tool marks created by a firearm and can provide improved discrimination between the comparison scores of samples fired from the same firearm and the scores of samples fired from different firearms. The algorithm also provides a convenient method for visualizing areas of similarity that may be useful in providing quantitative support for visual comparisons by trained examiners.
Adaptive reference voltage generator for firing angle control of line-commutated inverters
NASA Technical Reports Server (NTRS)
Dolland, C. R. (Inventor)
1983-01-01
A control system for a permanent-magnet motor driven by a multiphase line-commulated inverter is described. It is provided with integrators for integrating the back EMF of each phase of the motor for use in generating system control signals for an inverter gate logic using a sync and firing angle control generator connected to the outputs of the integrators. The firing angle control signals are produced by the control generator by means for combining 120 deg segments of the integrated back EMF signals symmetrical about their maxima into composite positive and negative waveforms, and means for sampling the maxima of each waveform every 120 deg. These samples are then used as positive and negative firing angle control signals. Whereby any change in amplitude of the integrated back EMF signals will not affect a change in the operating power factor of the motor and inverter.
Yang, Hang; Zhang, Yongxin; Zheng, Chenghang; Wu, Xuecheng; Chen, Linghong; Gao, Xiang; Fu, Joshua S
2018-05-10
The pollutant abatement systems are widely applied in the coal-fired power sector and the energy consumption was considered an important part of the auxiliary power. An energy consumption analysis and assessment model of pollutant abatement systems in a power unit was developed based on the dynamic parameters and technology. The energy consumption of pollutant abatement systems in a 1000 MW coal-fired power unit which meet the ultra-low emission limits and the factors of operating parameters including unit load and inlet concentration of pollutants on the operating power were analyzed. The results show that the total power consumption of the pollutant abatement systems accounted for 1.27% of the gross power generation during the monitoring period. The WFGD system consumed 67% of the rate while the SCR and ESP systems consumed 8.9% and 24.1%. The power consumption rate of pollutant abatement systems decreased with the increase of unit load and increased with the increase of the inlet concentration of pollutants. The operation adjustment was also an effective method to increase the energy efficiency. For example, the operation adjustment of slurry circulation pumps could promote the energy-saving operation of WFGD system. Implication Statement The application of pollutant abatement technologies increases the internal energy consumption of the power plant, which will lead to an increase of power generation costs. The real-time energy consumption of the different pollutant abatement systems in a typical power unit is analyzed based on the dynamic operating data. Further, the influence of different operating parameters on the operating power of the system and the possible energy-saving potential are analyzed.
Heat transfer mechanisms in poplar wood undergoing torrefaction
NASA Astrophysics Data System (ADS)
Sule, Idris O.; Mahmud, Shohel; Dutta, Animesh; Tasnim, Syeda Humaira
2016-03-01
Torrefaction, a thermal treatment process of biomass, has been proved to improve biomass combustible properties. Torrefaction is defined as a thermochemical process in reduced oxygen condition and at temperature range from 200 to 300 °C for shorter residence time whereby energy yield is maximized, can be a bridging technology that can lead the conventional system (e.g. coal-fired plants) towards a sustainable energy system. In efforts to develop a commercial operable torrefaction reactor, the present study examines the minimum input condition at which biomass is torrefied and explores the heat transfer mechanisms during torrefaction in poplar wood samples. The heat transfer through the wood sample is numerically modeled and analyzed. Each poplar wood is torrefied at temperature of 250, 270, and 300 °C. The experimental study shows that the 270 °C-treatment can be deduced as the optimal input condition for torrefaction of poplar wood. A good understanding of heat transfer mechanisms can facilitate the upscaling and downscaling of torrefaction process equipment to fit the feedstock input criteria and can help to develop treatment input specifications that can maximize process efficiency.
1986-01-01
by sensors in the test cell and sampled, digitized, averaged, and calibrated by the facility computer system. The data included flowrates calculated ...before the next test could be started. This required about 2 minutes. 6.4 Combat Damage Testing Appendix C contains calculations and analysis...were comparable (Figure 7-5). Agent quantities required per MIL-E-22285 were again calculated using the equations noted in paragraph 7.1.1. The
Fire and vegetation history of the Jemez Mountains
Allen, Craig D.; Johnson, Peggy S.
2001-01-01
Historic patterns of fire occurrence and vegetation change in the Jemez Mountains of northern New Mexico have been described in detail by using multiple lines of evidence. Data sources include old aerial and ground-based photographs, historic records, charcoal deposits from bogs, fire-scarred trees (Figure 1), tree-ring reconstructions of precipitation, and field sampling of vegetation and soils. The forests and woodlands that cloak the Southwestern uplands provide the most extensive and detailed regional-scale network of fire history data available in the world (Swetnam and Baisan 1996, Swetnam et al. 1999, Allen 2002).
Emissions from simulated deep-seated fires in domestic waste.
Lönnermark, Anders; Blomqvist, Per; Marklund, Stellan
2008-01-01
The emissions from deep-seated fires in domestic waste have been investigated. The gas phase yields of PAH, PCDD/F, PCB, HCB, particles, and metals associated to the particulate matter were analysed during a series of simulated deep-seated fires. The method of extinguishment was varied and in cases where water was used for extinguishment, the runoff water was analysed for PAH, PCDD/F, PCB, hexachlorobenzene, and metals. In total six tests were performed. In four of the tests, samples of the fire residue were analysed for PCDD/F, PCBs, and chlorobenzenes.
NASA Astrophysics Data System (ADS)
Hanan, E. J.; Schimel, J.; Tague, C.
2012-12-01
Fire is a major restructuring force in Mediterranean-type ecosystems, inducing nutrient redistribution that is frequently invoked as a driver of ecosystem recovery. Fire regimes are expected to change with climate warming and associated droughts. To study watershed responses to high severity landscape fire, we combined ground-based sampling of soil nitrogen dynamics with modeling in two burned, chaparral-dominated watersheds. These two watersheds, Mission Canyon and Rattlesnake Canyon, span the foothills of the Santa Ynez Mountains in Santa Barbara County, California, and large portions of both watersheds burned in November 2008 and/or May 2009. We established fifteen burned and three unburned plots in November 2009 and monitored them on a monthly basis through June 2011 for a variety of ecosystem properties including water content, soil and foliar carbon and nitrogen, soil pH, exchangeable inorganic nitrogen, and microbial biomass. We then used the GIS-based hydro-biogeochemical model, Regional Hydro-Ecologic Simulation System (RHESSys) to to evaluate the effects of fire season, climate and hydrology on biogeochemical fluxes across the fire-scarred watersheds. Fires were imposed at the beginning and end of the growing season under various climates. Soil samples collected prior to the onset of rain were relatively enriched in ammonium, presumably due to ash residue deposition. Storm events then stimulated nitrification and pulses of mineralization. Ephemeral herbs established quickly following the first post-fire rain events, thereby maintaining ecosystem nutrient capital as shrubs gradually returned. Nitrate production was significantly enhanced in burned chaparral perhaps because fires elevated soil pH, which can both raise the solubility of soil organic matter, and stimulate nitrification, or perhaps because fires released nitrifying bacteria from competition with vegetation for ammonium. Overall however, nitrogen retention and export varied among plots, highlighting the complexity of ecosystem response to fire. Modeling results suggest that chaparral nutrients pools recover more slowly when fires occur at the end of the growing season, prior to the hot, dry summer. Thus climate impacts on the timing of fire are likely to alter trajectories of ecosystem recovery.
40 CFR 63.7575 - What definitions apply to this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... controlled flame combustion and having the primary purpose of recovering thermal energy in the form of steam... on its floor. Electric utility steam generating unit means a fossil fuel-fired combustion unit of more than 25 megawatts that serves a generator that produces electricity for sale. A fossil fuel-fired...
40 CFR 63.7575 - What definitions apply to this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... controlled flame combustion and having the primary purpose of recovering thermal energy in the form of steam... on its floor. Electric utility steam generating unit means a fossil fuel-fired combustion unit of more than 25 megawatts that serves a generator that produces electricity for sale. A fossil fuel-fired...
Albert J. Simard; Donald A. Haines; Richard W. Blank; John S. Frost
1983-01-01
Describes the Mack Lake Fire near Mio, Michigan. Few documented wildfires have exceeded its average spread rate (2 mi/h) and energy release rate (8,800 Btu/ft/sec). The extreme behavior resulted from high winds, low humidity, low fuel moisture and jack pine fuels. Horizontal roll vortices may have contributed to the death of one firefighter.
Impact of prescribed fire on understory and forest floor nutrients
Walter A. Hough
1981-01-01
The impact of low-intensity prescribed fires on slash pine/saw-palmetto/gallberry understory and forest floor nutrients was estimated from measurements before and after burning. Highly significant correlations existed between weight loss of these fuel components and the weight loss of several elements. Energy loss was also highly correlated with forestfloor and...
A Review of Water Mist Technology for Fire Suppression
1994-09-30
Smith, D.P., and Ball, D.N. (1993), "New Applications of Aqueous Agents for Fire Suppression," Halen Alternatives Technical Working Conference...Flows," Prog. Energy, Combust. ScL, 14, 1988, pp. 171-194. Dabros, T., and Van de Ven, T.G.M. (1992), "Hydrodynamic Interactions between Two Spheres Near
Greene, Michael A
2012-06-01
Comparison of characteristics of fire with non-fire households to determine factors differentially associated with fire households (fire risk factors). National household telephone survey in 2004-2005 by the US Consumer Product Safety Commission with 916 fire households and a comparison sample of 2161 non-fire households. There were an estimated 7.4 million fires (96.6% not reported to fire departments) with 130,000 injuries. Bivariate analysis and multivariate logistic regression analyses to assess differences in household characteristics. Significant factors associated with fire households were renting vs. owning (OR 1.988 p<0.0001); household members under 18 year of age (OR 1.277 p<0.0001); lack of residents over 64 years old (OR 0.552 p=0.0007); and college or higher education (some college OR 1.444 p=0.0360, college graduate OR 1.873, p<0.0001, postgraduate OR 2.156 p<0.0001). Not significant were age of house; race; ethnicity; and income. Number of smokers was borderline significant (OR 1.132 p=0.1019) but was significant in the subset of fire households with non-cooking fires (OR 1.383 p=0.0011). Single family houses were associated with non-fire households in the bivariate analysis but not in the multivariate analyses. Renting, household members under 18 years old and smokers are risk factors for unattended fires, similar to the literature for fatal and injury fires. Differences included household members over 65 years old (associated with non-fire households), college/postgraduate education (associated with fire households) and lack of significance of income. Preventing cooking fires (64% of survey incidents), smoking prevention efforts and fire prevention education for families with young children have the potential for reducing unattended fires and injuries.
Genualdi, Susan A.; Killin, Robert K.; Woods, Jim; Wilson, Glenn; Schmedding, David; Massey Simonich, Staci L.
2014-01-01
The trans-Pacific and regional North American atmospheric transport of polycyclic aromatic hydrocarbons (PAHs) and pesticides in biomass burning emissions was measured in air masses from April to September 2003 at two remote sites in western North America. Mary’s Peak Observatory (MPO) is located in Oregon’s Coast Range and Cheeka Peak Observatory (CPO) is located on the tip of the Olympic Peninsula in Washington State. During this time period, both remote sites were influenced by PAH and pesticide emissions from forest fires in Siberia and regional fires in Oregon and Washington State. Concurrent samples were taken at both sites on June 2 and August 4, 2003. On these dates, CPO had elevated gas phase PAH, alpha-hexachlorocyclohexane and retene concentrations (p<0.05) and MPO had elevated retene, particulate phase PAH and levoglucosan concentrations due to trans-Pacific transport of emissions from fires in Siberia. In addition, during the April to September 2003 sampling period, CPO and MPO were influenced by emissions from regional fires that resulted in elevated levoglucosan, dacthal, endosulfan and gas phase PAH concentrations. Burned and unburned forest soil samples collected from the regional forest fire area showed that 34 to 100% of the pesticide mass was lost from soil due to burning. These data suggest that the transPacific and regional atmospheric transport of biomass burning emissions results in elevated PAH and pesticide concentrations in western North America. The elevated pesticide concentrations are likely due to re-emission of historically deposited pesticides from the soil and vegetation during the fire event. PMID:19320158
Post-mortem detection of gasoline residues in lung tissue and heart blood of fire victims.
Pahor, Kevin; Olson, Greg; Forbes, Shari L
2013-09-01
The purpose of this study was to determine whether gasoline residues could be detected post-mortem in lung tissue and heart blood of fire victims. The lungs and heart blood were investigated to determine whether they were suitable samples for collection and could be collected without contamination during an autopsy. Three sets of test subjects (pig carcasses) were investigated under two different fire scenarios. Test subjects 1 were anaesthetized following animal ethics approval, inhaled gasoline vapours for a short period and then euthanized. The carcasses were clothed and placed in a house where additional gasoline was poured onto the carcass post-mortem in one fire, but not in the other. Test subjects 2 did not inhale gasoline, were clothed and placed in the house and had gasoline poured onto them in both fires. Test subjects 3 were clothed but had no exposure to gasoline either ante- or post-mortem. Following controlled burns and suppression with water, the carcasses were collected, and their lungs and heart blood were excised at a necropsy. The headspace from the samples was analysed using thermal desorption-gas chromatography-mass spectroscopy. Gasoline was identified in the lungs and heart blood from the subjects that were exposed to gasoline vapours prior to death (test subjects 1). All other samples were negative for gasoline residues. These results suggest that it is useful to analyse for volatile ignitable liquids in lung tissue and blood as it may help to determine whether a victim was alive and inhaling gases at the time of a fire.
Studies of the physical aspects of intumescence using advance diagnostics methods
NASA Astrophysics Data System (ADS)
Saeed, Hussain; Huang, Hua Wei; Zhang, Yang
2014-04-01
The use of intumescent paints as an active fire protection method has gained immense interest in recent years. A significant aspect of research has focused on studying the chemical aspects of the system to improve performance. The dynamics and physical aspects of intumescence in real time fire conditions are still unclear. The present research uses an experimental approach where diagnostics techniques such as thermal imaging camera was used to study intumescent characteristics that have been not been reported in great detail. T-panels are a substitute to the most commonly used part in construction, the I-beam. Studies were conducted using a cone calorimeter that provided a uniform heat flux through radiation on steel T-panel samples. The complex nature of char movement was recorded and a novel algorithm was used to track the growing char laye07r. The samples are designed to cater to different fire conditions. Therefore, the degree of intumescence was observed to be very different in the samples. The samples designed for low temperature cellulosic fires focus on high degree of intumesce. Whereas, mechanical strength is the focus for samples used in high temperature turbulent hydrocarbon fire conditions. The variation in the internal structure of the sample is presented. Furthermore, the phenomenon is phase shift is discussed. The phase shift is an essential part of the process of intumescence when the majority of intumescence occurs. It was observed to be different in all the samples. The movement of the samples is a property of great interest. This is because if any part of the substrate is exposed then the formulation does not meet strict commercialisation criterion. The movement was diagonal in nature as compared to flat panels where it is perpendicular. This is due tot the heating pattern of the plate that results in the web part of the panel to influence the growth of char on the flange part of the panel. A special case of char cracking is also highlighted and using image processing algorithm on the thermal imaging data. A quantitative method of analsysis is presented to an otherwise commonly qualitative nature of experimental study in this field.
NASA Astrophysics Data System (ADS)
Ward, Tony J.
A yearlong sampling program for PM2.5, Semi- Volatile Organic Compounds (SVOCs), and Volatile Organic Compounds (VOCs) was conducted in 2000/2001. The data were used in a Chemical Mass Balance (CMB) Source Apportionment Model (Version 8.0) to apportion the sources of PM2.5 in the Missoula Valley. Results showed that wood combustion contributed an average of 41% to the fine fraction throughout the year. The second largest source of PM 2.5 was diesel (19%), followed by ammonium nitrate (17%), the kraft recovery boilers from Smurfit-Stone Container (14%), other hog fuel boilers (6%), and street sand (5%). Results also showed that PM2.5 levels and contributions from sources were consistent on both sides of the Missoula Valley, but VOCs were twice as high in Missoula compared to Frenchtown. Another aspect of this program was to investigate the organic fraction of the Missoula Valley PM2.5 by evaluating a modified Federal Reference Method (FRM) PM2.5 sampler. A method comparison was also made between sampling for SVOCs using the modified PM2.5 sampler and in using a Hi-volume Polyurethane Foam (PUF) sampler. Results showed that the PM 2.5 PUF measured more of the lighter SVOCs compared to the Hi-vol PUF sampler. This is most likely the result of the higher flows through the Hi-vol PUF which ``strip'' the lighter organics from the surface of the filter. The wildland fires of summer 2000 comprised one of the most severe fire seasons is U.S. history, and had a direct impact on the city of Missoula. Sampling in Missoula was already in progress when the fires began and smoke started rolling into the Missoula Valley. Samples were collected before, during, and after the 2000 fire season, and a detailed characterization of particulate and gaseous emissions from extensive wildland fires was obtained. The 2000/2001 CMB Sampling Program data collected during the 2000 fire season suggest that the main health impacts to downwind populations reside in the fine particulate exposures, with an average of 81% of the Missoula Valley PM2.5 resulting from forest fires.
Aerostat-based sampling of emissions from open burning and open detonation of military ordnance.
Aurell, Johanna; Gullett, Brian K; Tabor, Dennis; Williams, Ryan K; Mitchell, William; Kemme, Michael R
2015-03-02
Emissions from open detonation (OD), open burning (OB), and static firing (SF) of obsolete military munitions were collected using an aerostat-lofted sampling instrument maneuvered into the plumes with remotely controlled tether winches. PM2.5, PM10, metals, volatile organic compounds (VOCs), energetics, and polyaromatic hydrocarbons (PAHs) were characterized from 121 trials of three different munitions (Composition B (hereafter, "Comp B"), V453, V548), 152 trials of five different propellants (M31A1E1, M26, SPCF, Arc 451, 452A), and 12 trials with static firing of ammonium perchlorate-containing Sparrow rocket motors. Sampling was conducted with operational charge sizes and under open area conditions to determine emission levels representative of actual disposal practices. The successful application of the tethered aerostat and sampling instruments demonstrated the ability to sample for and determine the first ever emission factors for static firing of rocket motors and buried and metal-cased OD, as well as the first measurements of PM2.5 for OB and for surface OD. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Middlebrook, A. M.; Adler, G. A.; Coggon, M.; De Gouw, J. A.; Franchin, A.; Gilman, J.; Koss, A.; Krechmer, J. E.; Lamb, K.; Manfred, K.; Roberts, J. M.; Schwarz, J. P.; Sekimoto, K.; Selimovic, V.; Stockwell, C.; Wagner, N.; Warneke, C.; Washenfelder, R. A.; Womack, C.; Yokelson, R. J.; Yuan, B.
2017-12-01
During the 2016 NOAA FIREX project at the Missoula Fire Sciences Laboratory, small fires of known fuel type and properties were ignited to characterize their direct emissions with a large variety of new sampling methods. Two types of experiments were employed: sampling smoke directly from the exhaust stack throughout the lifecycle of the fires (stack burns) or sampling when the exhaust vent was closed to fill the room with smoke (room burns). For both types of burns, photo-oxidation chambers were at times used to mimic aging in the atmosphere. During all these experiments, we measured the non-refractory components of the smoke particles using an Aerodyne compact time-of-flight aerosol mass spectrometer (AMS) with a light scattering module and diluted the sample line as little as possible (usually by a factor of 10) without overwhelming our instrument. For the stack burns, our AMS was placed near the top of the exhaust stack to capture the composition and size distribution during the rapidly changing stages of the fires. We found that the chemical composition of the aerosols varied with fuel type and combustion conditions on time scales of a few minutes as the fuels went through different stages of heating and combustion. For the room burns, we obtained additional measurements with the light-scattering module aimed at understanding how well smoke particles are measured with the AMS, along with characterization of their physical properties. We will present a summary of our results, with connections to their relevance for constraining model treatments of fire emissions on the atmosphere.
Political and technical issues of coal fire extinction in the Kyoto framework
NASA Astrophysics Data System (ADS)
Meyer, U.; Chen-Brauchler, D.; Rüter, H.; Fischer, C.; Bing, K.
2009-04-01
It is a highly desirable effort to extinguish as much coal fires as possible in short time to prevent large losses of energy resources and to minimise CO2 and other exhaust gas releases from such sources. Unfortunately, extinguishing coal fires needs massive financial investments, skilled man power, suited technology and a long time. Even mid to small scale coal fires need several months of extinguishing measures and of monitoring time after extinction resulting in expenditures of a minimum of several hundred thousand Euros. Large companies might be willing to spend money for coal fire extinction measures but smaller holdings or regional governments might not have the monetary resources for it. Since there is no law in China that demands coal fire extinction, measures under the Kyoto framework may be applied to sell CO2 certificates for prevented emissions from extinguished coal fires and thus used as a financial stimulus for coal fire extinction activities. The set-up for methodologies and project designs is especially complex for coal fire extinction measures and thus for necessary exploration, evaluation and monitoring using geophysical and remote sensing methods. A brief overview of most important formal and technical aspects is given to outline the conditions for a potentially successful CDM application on coal fires based on geophysical observations and numerical modelling.