Energy savings potential from improved building controls for the US commercial building sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernandez, Nick; Katipamula, Srinivas; Wang, Weimin
The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sectormore » energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29%; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.« less
Calendar Year 2007 Program Benefits for U.S. EPA Energy Star Labeled Products: Expanded Methodology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanchez, Marla; Homan, Gregory; Lai, Judy
2009-09-24
This report provides a top-level summary of national savings achieved by the Energy Star voluntary product labeling program. To best quantify and analyze savings for all products, we developed a bottom-up product-based model. Each Energy Star product type is characterized by product-specific inputs that result in a product savings estimate. Our results show that through 2007, U.S. EPA Energy Star labeled products saved 5.5 Quads of primary energy and avoided 100 MtC of emissions. Although Energy Star-labeled products encompass over forty product types, only five of those product types accounted for 65percent of all Energy Star carbon reductions achieved tomore » date, including (listed in order of savings magnitude)monitors, printers, residential light fixtures, televisions, and furnaces. The forecast shows that U.S. EPA?s program is expected to save 12.2 Quads of primary energy and avoid 215 MtC of emissions over the period of 2008?2015.« less
Shared Savings Financing for College and University Energy Efficiency Investments.
ERIC Educational Resources Information Center
Business Officer, 1984
1984-01-01
Shared savings arrangements for campus energy efficient investments are discussed. Shared savings is a term for an agreement in which a private company offers to implement an energy efficiency program, including capital improvements, in exchange for a portion of the energy cost savings. Attention is directed to: types of shared savings…
Energy Savings Measure Packages. Existing Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casey, Sean; Booten, Chuck
2011-11-01
This document presents the most cost effective Energy Savings Measure Packages (ESMP) for existing mixed-fuel and all electric homes to achieve 15% and 30% savings for each BetterBuildings grantee location across the United States. These packages are optimized for minimum cost to homeowners for source energy savings given the local climate and prevalent building characteristics (i.e. foundation types). Maximum cost savings are typically found between 30% and 50% energy savings over the reference home; this typically amounts to $300 - $700/year.
Simulation-based model to explore the benefits of monitoring and control to energy saving opportunities in residential homes; an adaptive algorithm to predict the type of electrical loads; a prototype user friendly interface monitoring and control device to save energy; a p...
Development of Design Guidance for K-12 Schools: From 30% to 50% Energy Savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pless, S.; Torcellini, P.; Long, N.
2008-01-01
This paper describes the development of energy efficiency recommendations for achieving 30% whole-building energy savings in K-12 Schools over levels achieved by following the ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings (1999 and 2004 versions). Exhaustive simulations were run to create packages of energy design solutions available over a wide range of K-12 schools and climates. These design recommendations look at building envelope, fenestration, lighting systems (including electrical lights and daylighting), HVAC systems, building automation and controls, outside air treatment, and service water heating. We document and discuss the energy modeling performed to demonstrate that themore » recommendations will result in at least 30% energy savings over ASHRAE 90.1-1999 and ASHRAE 90.1-2004. Recommendations are evaluated based on the availability of daylighting for the school and by the type of HVAC system. Compared to the ASHRAE 90.1-1999 baseline, the recommendations result in more than 30% savings in all climate zones for both daylit and nondaylit elementary, middle, and high schools with a range of HVAC system types. These recommendations have been included in the Advanced Energy Design Guide for K-12 School Buildings. Compared to the more stringent ASHRAE 90.1-2004 baseline, the recommendations result in more than 30% savings in all climate zones, for only the daylit elementary, middle, and high schools, with a range of HVAC system types. To inform the future development of recommendations for higher level of energy savings, we analyzed a subset of recommendations to understand which energy efficiency technologies would be needed to achieve 50% energy savings.« less
NASA Astrophysics Data System (ADS)
Kwon, Hyuk Ju; Yeon, Sang Hun; Lee, Keum Ho; Lee, Kwang Ho
2018-02-01
As various studies focusing on building energy saving have been continuously conducted, studies utilizing renewable energy sources, instead of fossil fuel, are needed. In particular, studies regarding solar energy are being carried out in the field of building science; in order to utilize such solar energy effectively, solar radiation being brought into the indoors should be acquired and blocked properly. Blinds are a typical solar radiation control device that is capable of controlling indoor thermal and light environments. However, slat-type blinds are manually controlled, giving a negative effect on building energy saving. In this regard, studies regarding the automatic control of slat-type blinds have been carried out for the last couple of decades. Therefore, this study aims to provide preliminary data for optimal control research through the controlling of slat angle in slat-type blinds by comprehensively considering various input variables. The window area ratio and orientation were selected as input variables. It was found that an optimal control algorithm was different among each window-to-wall ratio and window orientation. In addition, through comparing and analyzing the building energy saving performance for each condition by applying the developed algorithms to simulations, up to 20.7 % energy saving was shown in the cooling period and up to 12.3 % energy saving was shown in the heating period. In addition, building energy saving effect was greater as the window area ratio increased given the same orientation, and the effects of window-to-wall ratio in the cooling period were higher than those of window-to-wall ratio in the heating period.
A multifunctional energy-saving magnetic field generator.
Xiong, Hui; Sun, Wanpeng; Liu, Jinzhen; Shi, Jinhua
2018-03-01
To improve the energy utilization of magnetic field generators for biological applications, a multifunctional energy-saving magnetic field generator (ESMFG) is presented. It is capable of producing both an alternating magnetic field (AMF) and a bipolar pulse magnetic field (BPMF) with high energy-saving and energy-reuse rates. Based on a theoretical analysis of an RLC second-order circuit, the energy-saving and energy-reuse rates of both types of magnetic fields can be calculated and are found to have acceptable values. The results of an experimental study using the proposed generator show that for the BPMF, the peak current reaches 130 A and the intensity reaches 70.3 mT. For the AMF, the intensity is 11.0 mT and the RMS current is 20 A. The energy-saving and energy-reuse rates for the AMF generator are 61.3% and 63.5%, respectively, while for the BPMF generator, the energy-saving rate is 33.6%. Thus, the proposed ESMFG has excellent potential for use in biomedical applications.
A multifunctional energy-saving magnetic field generator
NASA Astrophysics Data System (ADS)
Xiong, Hui; Sun, Wanpeng; Liu, Jinzhen; Shi, Jinhua
2018-03-01
To improve the energy utilization of magnetic field generators for biological applications, a multifunctional energy-saving magnetic field generator (ESMFG) is presented. It is capable of producing both an alternating magnetic field (AMF) and a bipolar pulse magnetic field (BPMF) with high energy-saving and energy-reuse rates. Based on a theoretical analysis of an RLC second-order circuit, the energy-saving and energy-reuse rates of both types of magnetic fields can be calculated and are found to have acceptable values. The results of an experimental study using the proposed generator show that for the BPMF, the peak current reaches 130 A and the intensity reaches 70.3 mT. For the AMF, the intensity is 11.0 mT and the RMS current is 20 A. The energy-saving and energy-reuse rates for the AMF generator are 61.3% and 63.5%, respectively, while for the BPMF generator, the energy-saving rate is 33.6%. Thus, the proposed ESMFG has excellent potential for use in biomedical applications.
Energy efficiency in California laboratory-type facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mills, E.; Bell, G.; Sartor, D.
The central aim of this project is to provide knowledge and tools for increasing the energy efficiency and performance of new and existing laboratory-type facilities in California. We approach the task along three avenues: (1) identification of current energy use and savings potential, (2) development of a {ital Design guide for energy- Efficient Research Laboratories}, and (3) development of a research agenda for focused technology development and improving out understanding of the market. Laboratory-type facilities use a considerable amount of energy resources. They are also important to the local and state economy, and energy costs are a factor in themore » overall competitiveness of industries utilizing laboratory-type facilities. Although the potential for energy savings is considerable, improving energy efficiency in laboratory-type facilities is no easy task, and there are many formidable barriers to improving energy efficiency in these specialized facilities. Insufficient motivation for individual stake holders to invest in improving energy efficiency using existing technologies as well as conducting related R&D is indicative of the ``public goods`` nature of the opportunity to achieve energy savings in this sector. Due to demanding environmental control requirements and specialized processes, laboratory-type facilities epitomize the important intersection between energy demands in the buildings sector and the industrial sector. Moreover, given the high importance and value of the activities conducted in laboratory-type facilities, they represent one of the most powerful contexts in which energy efficiency improvements stand to yield abundant non-energy benefits if properly applied.« less
Incorporating Non-energy Benefits into Energy Savings Performance Contracts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larsen, Peter; Goldman, Charles; Gilligan, Donald
2012-06-01
This paper evaluates the issue of non-energy benefits within the context of the U.S. energy services company (ESCO) industry?a growing industry comprised of companies that provide energy savings and other benefits to customers through the use of performance-based contracting. Recent analysis has found that ESCO projects in the public/institutional sector, especially at K-12 schools, are using performance-based contracting, at the behest of the customers, to partially -- but not fully -- offset substantial accumulated deferred maintenance needs (e.g., asbestos removal, wiring) and measures that have very long paybacks (roof replacement). This trend is affecting the traditional economic measures policymakers usemore » to evaluate success on a benefit to cost basis. Moreover, the value of non-energy benefits which can offset some or all of the cost of the non-energy measures -- including operations and maintenance (O&M) savings, avoided capital costs, and tradable pollution emissions allowances-- are not always incorporated into a formal cost-effectiveness analysis of ESCO projects. Nonenergy benefits are clearly important to customers, but state and federal laws that govern the acceptance of these types of benefits for ESCO projects vary widely (i.e., 0-100percent of allowable savings can come from one or more non-energy categories). Clear and consistent guidance on what types of savings are recognized in Energy Savings agreements under performance contracts is necessary, particularly where customers are searching for deep energy efficiency gains in the building sector.« less
Strategies to improve energy efficiency in sewage treatment plants
NASA Astrophysics Data System (ADS)
Au, Mau Teng; Pasupuleti, Jagadeesh; Chua, Kok Hua
2013-06-01
This paper discusses on strategies to improve energy efficiency in Sewage Treatment Plant (STP). Four types of STP; conventional activated sludge, extended aeration, oxidation ditch, and sequence batch reactor are presented and strategized to reduce energy consumption based on their influent flow. Strategies to reduce energy consumption include the use of energy saving devices, energy efficient motors, automation/control and modification of processes. It is envisaged that 20-30% of energy could be saved from these initiatives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mort, Dan
Estimated energy savings are calculated as the difference between the energy use during the baseline period and the energy use during the post installation period of the EEM. This chapter describes the physical properties measured in the process of evaluating EEMs and the specific metering methods for several types of measurements. Skill-level requirements and other operating considerations are discussed, including where, when, and how often measurements should be made. The subsequent section identifies metering equipment types and their respective measurement accuracies. This is followed by sections containing suggestions regarding proper data handling procedures and the categorization and definition of severalmore » load types.« less
The present study is aimed at seeking a better understanding of the thermodynamics involved with the air distribution strategies associated with UFAD systems and its impact on the energy saving dynamics.
Thus objectives are:
Shi, Xiao-Qing; Li, Xiao-Nuo; Yang, Jian-Xin
2013-01-01
Transportation is the key industry of urban energy consumption and carbon emissions. The transformation of conventional gasoline vehicles to new energy vehicles is an important initiative to realize the goal of developing low-carbon city through energy saving and emissions reduction, while electric vehicles (EV) will play an important role in this transition due to their advantage in energy saving and lower carbon emissions. After reviewing the existing researches on energy saving and emissions reduction of electric vehicles, this paper analyzed the factors affecting carbon emissions reduction. Combining with electric vehicles promotion program in Beijing, the paper analyzed carbon emissions and reduction potential of electric vehicles in six scenarios using the optimized energy consumption related carbon emissions model from the perspective of fuel life cycle. The scenarios included power energy structure, fuel type (energy consumption per 100 km), car type (CO2 emission factor of fuel), urban traffic conditions (speed), coal-power technologies and battery type (weight, energy efficiency). The results showed that the optimized model was able to estimate carbon emissions caused by fuel consumption more reasonably; electric vehicles had an obvious restrictive carbon reduction potential with the fluctuation of 57%-81.2% in the analysis of six influencing factors, while power energy structure and coal-power technologies play decisive roles in life-cycle carbon emissions of electric vehicles with the reduction potential of 78.1% and 81.2%, respectively. Finally, some optimized measures were proposed to reduce transport energy consumption and carbon emissions during electric vehicles promotion including improving energy structure and coal technology, popularizing energy saving technologies and electric vehicles, accelerating the battery R&D and so on. The research provides scientific basis and methods for the policy development for the transition of new energy vehicles in low-carbon transport.
50% Advanced Energy Design Guides: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonnema, E.; Leach, M.; Pless, S.
2012-07-01
This paper presents the process, methodology, and assumptions for the development of the 50% Energy Savings Advanced Energy Design Guides (AEDGs), a design guidance document that provides specific recommendations for achieving 50% energy savings above the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004 in four building types: (1) Small to medium office buildings, (2) K-12 school buildings, (3) Medium to big box retail buildings, (4) Large hospital buildings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffman, Ian M.
With rising interest in lowering energy costs for low- and moderate-income households, the U.S. Department of Energy (DOE) asked Lawrence Berkeley National Laboratory (LBNL) to assess the implications of pursuing energy efficiency neighborhood-by-neighborhood where those households are most prevalent. DOE provided certain scenarios for qualifying geographic areas as “low- and moderate-income communities,” and LBNL used data on demographics, housing types and recent savings from low-income retrofits or weatherization to provide rough electricity savings estimates under those scenarios.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todd, A.; Perry, M.; Smith, B.
2014-12-01
In this report, we use smart meter data to analyze specific actions, behaviors, and characteristics that drive energy savings in a BB program. Specifically, we examine a Home Energy Report (HER) program. These programs typically obtain 1% to 3% annual savings, and recent studies have shown hourly savings of between 0.5% and 3%.1 But what is driving these savings? What types of households tend to be “high-savers,” and what behaviors are they adopting? There are several possibilities: one-time behaviors (e.g., changing thermostat settings), reoccurring habitual behaviors (e.g., turning off lights), and equipment purchase behaviors (e.g., energy efficient appliances); these maymore » vary across households, regions, and over time.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todd, Annika; Perry, Michael; Smith, Brian
2014-12-01
In this report, we use smart meter data to analyze specific actions, behaviors, and characteristics that drive energy savings in a behavior-based (BB) program. Specifically, we examine a Home Energy Report (HER) program. These programs typically obtain 1% to 3% annual savings, and recent studies have shown hourly savings of between 0.5% and 3%. But what is driving these savings? What types of households tend to be “high-savers”, and what behaviors are they adopting? There are several possibilities: one-time behaviors (e.g., changing thermostat settings); reoccurring habitual behaviors (e.g., turning off lights); and equipment purchase behaviors (e.g., energy efficient appliances), andmore » these may vary across households, regions, and over time.« less
Sun, Kaiyu; Hong, Tianzhen
2017-04-27
To improve energy efficiency—during new buildings design or during a building retrofit—evaluating the energy savings potential of energy conservation measures (ECMs) is a critical task. In building retrofits, occupant behavior significantly impacts building energy use and is a leading factor in uncertainty when determining the effectiveness of retrofit ECMs. Current simulation-based assessment methods simplify the representation of occupant behavior by using a standard or representative set of static and homogeneous assumptions ignoring the dynamics, stochastics, and diversity of occupant's energy-related behavior in buildings. The simplification contributes to significant gaps between the simulated and measured actual energy performance of buildings. Thismore » paper presents a framework for quantifying the impact of occupant behaviors on ECM energy savings using building performance simulation. During the first step of the study, three occupant behavior styles (austerity, normal, and wasteful) were defined to represent different levels of energy consciousness of occupants regarding their interactions with building energy systems (HVAC, windows, lights and plug-in equipment). Next, a simulation workflow was introduced to determine a range of the ECM energy savings. Then, guidance was provided to interpret the range of ECM savings to support ECM decision making. Finally, a pilot study was performed in a real building to demonstrate the application of the framework. Simulation results show that the impact of occupant behaviors on ECM savings vary with the type of ECM. Occupant behavior minimally affects energy savings for ECMs that are technology-driven (the relative savings differ by less than 2%) and have little interaction with the occupants; for ECMs with strong occupant interaction, such as the use of zonal control variable refrigerant flow system and natural ventilation, energy savings are significantly affected by occupant behavior (the relative savings differ by up to 20%). Finally, the study framework provides a novel, holistic approach to assessing the uncertainty of ECM energy savings related to occupant behavior, enabling stakeholders to understand and assess the risk of adopting energy efficiency technologies for new and existing buildings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Kaiyu; Hong, Tianzhen
To improve energy efficiency—during new buildings design or during a building retrofit—evaluating the energy savings potential of energy conservation measures (ECMs) is a critical task. In building retrofits, occupant behavior significantly impacts building energy use and is a leading factor in uncertainty when determining the effectiveness of retrofit ECMs. Current simulation-based assessment methods simplify the representation of occupant behavior by using a standard or representative set of static and homogeneous assumptions ignoring the dynamics, stochastics, and diversity of occupant's energy-related behavior in buildings. The simplification contributes to significant gaps between the simulated and measured actual energy performance of buildings. Thismore » paper presents a framework for quantifying the impact of occupant behaviors on ECM energy savings using building performance simulation. During the first step of the study, three occupant behavior styles (austerity, normal, and wasteful) were defined to represent different levels of energy consciousness of occupants regarding their interactions with building energy systems (HVAC, windows, lights and plug-in equipment). Next, a simulation workflow was introduced to determine a range of the ECM energy savings. Then, guidance was provided to interpret the range of ECM savings to support ECM decision making. Finally, a pilot study was performed in a real building to demonstrate the application of the framework. Simulation results show that the impact of occupant behaviors on ECM savings vary with the type of ECM. Occupant behavior minimally affects energy savings for ECMs that are technology-driven (the relative savings differ by less than 2%) and have little interaction with the occupants; for ECMs with strong occupant interaction, such as the use of zonal control variable refrigerant flow system and natural ventilation, energy savings are significantly affected by occupant behavior (the relative savings differ by up to 20%). Finally, the study framework provides a novel, holistic approach to assessing the uncertainty of ECM energy savings related to occupant behavior, enabling stakeholders to understand and assess the risk of adopting energy efficiency technologies for new and existing buildings.« less
Window Insulation: How to Sort Through the Options.
ERIC Educational Resources Information Center
Miller, Barbara
This two-part report explores the efforts of businesses and individuals to improve the thermal performance of windows. Part I discusses the basics of what makes a window product insulate or save energy. Topic areas addressed include saving energy lost through windows, key components of window insulation, three basic types of window insulation,…
Measured energy savings and performance of power-managed personal computers and monitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nordman, B.; Piette, M.A.; Kinney, K.
1996-08-01
Personal computers and monitors are estimated to use 14 billion kWh/year of electricity, with power management potentially saving $600 million/year by the year 2000. The effort to capture these savings is lead by the US Environmental Protection Agency`s Energy Star program, which specifies a 30W maximum demand for the computer and for the monitor when in a {open_quote}sleep{close_quote} or idle mode. In this paper the authors discuss measured energy use and estimated savings for power-managed (Energy Star compliant) PCs and monitors. They collected electricity use measurements of six power-managed PCs and monitors in their office and five from two othermore » research projects. The devices are diverse in machine type, use patterns, and context. The analysis method estimates the time spent in each system operating mode (off, low-, and full-power) and combines these with real power measurements to derive hours of use per mode, energy use, and energy savings. Three schedules are explored in the {open_quotes}As-operated,{close_quotes} {open_quotes}Standardized,{close_quotes} and `Maximum` savings estimates. Energy savings are established by comparing the measurements to a baseline with power management disabled. As-operated energy savings for the eleven PCs and monitors ranged from zero to 75 kWh/year. Under the standard operating schedule (on 20% of nights and weekends), the savings are about 200 kWh/year. An audit of power management features and configurations for several dozen Energy Star machines found only 11% of CPU`s fully enabled and about two thirds of monitors were successfully power managed. The highest priority for greater power management savings is to enable monitors, as opposed to CPU`s, since they are generally easier to configure, less likely to interfere with system operation, and have greater savings. The difficulties in properly configuring PCs and monitors is the largest current barrier to achieving the savings potential from power management.« less
Sun, K; Hong, T
2017-07-01
© 2017 Elsevier B.V. To improve energy efficiency—during new buildings design or during a building retrofit—evaluating the energy savings potential of energy conservation measures (ECMs) is a critical task. In building retrofits, occupant behavior significantly impacts building energy use and is a leading factor in uncertainty when determining the effectiveness of retrofit ECMs. Current simulation-based assessment methods simplify the representation of occupant behavior by using a standard or representative set of static and homogeneous assumptions ignoring the dynamics, stochastics, and diversity of occupant's energy-related behavior in buildings. The simplification contributes to significant gaps between the simulated and measured actual energymore » performance of buildings. This study presents a framework for quantifying the impact of occupant behaviors on ECM energy savings using building performance simulation. During the first step of the study, three occupant behavior styles (austerity, normal, and wasteful) were defined to represent different levels of energy consciousness of occupants regarding their interactions with building energy systems (HVAC, windows, lights and plug-in equipment). Next, a simulation workflow was introduced to determine a range of the ECM energy savings. Then, guidance was provided to interpret the range of ECM savings to support ECM decision making. Finally, a pilot study was performed in a real building to demonstrate the application of the framework. Simulation results show that the impact of occupant behaviors on ECM savings vary with the type of ECM. Occupant behavior minimally affects energy savings for ECMs that are technology-driven (the relative savings differ by less than 2%) and have little interaction with the occupants; for ECMs with strong occupant interaction, such as the use of zonal control variable refrigerant flow system and natural ventilation, energy savings are significantly affected by occupant behavior (the relative savings differ by up to 20%). The study framework provides a novel, holistic approach to assessing the uncertainty of ECM energy savings related to occupant behavior, enabling stakeholders to understand and assess the risk of adopting energy efficiency technologies for new and existing buildings.« less
Potential reduction of energy consumption in public university library
NASA Astrophysics Data System (ADS)
Noranai, Z.; Azman, ADF
2017-09-01
Efficient electrical energy usage has been recognized as one of the important factor to reduce cost of electrical energy consumption. Various parties have been emphasized about the importance of using electrical energy efficiently. Inefficient usage of electrical energy usage lead to biggest factor increasing of administration cost in Universiti Tun Hussein Onn Malaysia. With this in view, a project the investigate potential reduction electrical energy consumption in Universiti Tun Hussein Onn Malaysia was carried out. In this project, a case study involving electrical energy consumption of Perpustakaan Tunku Tun Aminah was conducted. The scopes of this project are to identify energy consumption in selected building and to find the factors that contributing to wastage of electrical energy. The MS1525:2001, Malaysian Standard - Code of practice on energy efficiency and use of renewable energy for non-residential buildings was used as reference. From the result, 4 saving measure had been proposed which is change type of the lamp, install sensor, decrease the number of lamp and improve shading coefficient on glass. This saving measure is suggested to improve the efficiency of electrical energy consumption. Improve of human behaviour toward saving energy measure can reduce 10% from the total of saving cost while on building technical measure can reduce 90% from total saving cost.
A regression-based approach to estimating retrofit savings using the Building Performance Database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walter, Travis; Sohn, Michael D.
Retrofitting building systems is known to provide cost-effective energy savings. This article addresses how the Building Performance Database is used to help identify potential savings. Currently, prioritizing retrofits and computing their expected energy savings and cost/benefits can be a complicated, costly, and an uncertain effort. Prioritizing retrofits for a portfolio of buildings can be even more difficult if the owner must determine different investment strategies for each of the buildings. Meanwhile, we are seeing greater availability of data on building energy use, characteristics, and equipment. These data provide opportunities for the development of algorithms that link building characteristics and retrofitsmore » empirically. In this paper we explore the potential of using such data for predicting the expected energy savings from equipment retrofits for a large number of buildings. We show that building data with statistical algorithms can provide savings estimates when detailed energy audits and physics-based simulations are not cost- or time-feasible. We develop a multivariate linear regression model with numerical predictors (e.g., operating hours, occupant density) and categorical indicator variables (e.g., climate zone, heating system type) to predict energy use intensity. The model quantifies the contribution of building characteristics and systems to energy use, and we use it to infer the expected savings when modifying particular equipment. We verify the model using residual analysis and cross-validation. We demonstrate the retrofit analysis by providing a probabilistic estimate of energy savings for several hypothetical building retrofits. We discuss the ways understanding the risk associated with retrofit investments can inform decision making. The contributions of this work are the development of a statistical model for estimating energy savings, its application to a large empirical building dataset, and a discussion of its use in informing building retrofit decisions.« less
Exploring efficacy of residential energy efficiency programs in Florida
NASA Astrophysics Data System (ADS)
Taylor, Nicholas Wade
Electric utilities, government agencies, and private interests in the U.S. have committed and continue to invest substantial resources in the pursuit of energy efficiency and conservation through demand-side management (DSM) programs. Program investments, and the demand for impact evaluations that accompany them, are projected to grow in coming years due to increased pressure from state-level energy regulation, costs and challenges of building additional production capacity, fuel costs and potential carbon or renewable energy regulation. This dissertation provides detailed analyses of ex-post energy savings from energy efficiency programs in three key sectors of residential buildings: new, single-family, detached homes; retrofits to existing single-family, detached homes; and retrofits to existing multifamily housing units. Each of the energy efficiency programs analyzed resulted in statistically significant energy savings at the full program group level, yet savings for individual participants and participant subgroups were highly variable. Even though savings estimates were statistically greater than zero, those energy savings did not always meet expectations. Results also show that high variability in energy savings among participant groups or subgroups can negatively impact overall program performance and can undermine marketing efforts for future participation. Design, implementation, and continued support of conservation programs based solely on deemed or projected savings is inherently counter to the pursuit of meaningful energy conservation and reductions in greenhouse gas emissions. To fully understand and optimize program impacts, consistent and robust measurement and verification protocols must be instituted in the design phase and maintained over time. Furthermore, marketing for program participation must target those who have the greatest opportunity for savings. In most utility territories it is not possible to gain access to the type of large scale datasets that would facilitate robust program analysis. Along with measuring and optimizing energy conservation programs, utilities should provide public access to historical consumption data. Open access to data, program optimization, consistent measurement and verification and transparency in reported savings are essential to reducing energy use and its associated environmental impacts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Yunzhi; Gowri, Krishnan
2011-02-28
This report summarizes code requirements and energy savings of commercial buildings in Climate Zone 2B built to the 2009 IECC and ASHRAE Standard 90.1-2007 when compared to the 2003 IECC and the 2006 IECC. In general, the 2009 IECC and ASHRAE Standard 90.1-2007 have higher insulation requirements for exterior walls, roof, and windows and have higher efficiency requirements for HVAC equipment. HVAC equipment efficiency requirements are governed by National Appliance Conversion Act of 1987 (NAECA), and are applicable irrespective of the IECC version adopted. The energy analysis results show that commercial buildings meeting the 2009 IECC requirements save 4.4% tomore » 9.5% site energy and 4.1% to 9.9% energy cost when compared to the 2006 IECC; and save 10.6% to 29.4% site energy and 10.3% to 29.3% energy cost when compared to the 2003 IECC. Similar analysis comparing ASHRAE Standard 90.1-2007 requirements to the 2006 IECC shows that the energy savings are in the 4.0% to 10.7% for multi-family and retail buildings, but less than 2% for office buildings. Further comparison of ASHRAE Standard 90.1-2007 requirements to the 2003 IECC show site energy savings in the range of 7.7% to 30.6% and energy cost savings range from 7.9% to 30.3%. Both the 2009 IECC and ASHRAE Standard 90.1-2007 have the potential to save energy by comparable levels for most building types.« less
Hester, Nathan; Li, Ke; Schramski, John R; Crittenden, John
2012-04-30
Globally, residential energy consumption continues to rise due to a variety of trends such as increasing access to modern appliances, overall population growth, and the overall increase of electricity distribution. Currently, residential energy consumption accounts for approximately one-fifth of total U.S. energy consumption. This research analyzes the effectiveness of a range of energy-saving measures for residential houses in semi-arid climates. These energy-saving measures include: structural insulated panels (SIP) for exterior wall construction, daylight control, increased window area, efficient window glass suitable for the local weather, and several combinations of these. Our model determined that energy consumption is reduced by up to 6.1% when multiple energy savings technologies are combined. In addition, pre-construction technologies (structural insulated panels (SIPs), daylight control, and increased window area) provide roughly 4 times the energy savings when compared to post-construction technologies (window blinds and efficient window glass). The model also illuminated the importance variations in local climate and building configuration; highlighting the site-specific nature of this type of energy consumption quantification for policy and building code considerations. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Cory, Bradley S.
The reEnergize Program conducted 957 energy upgrades in Omaha Nebraska from July 2010 to September 30th 2013, through a government grant within the Better Buildings Neighborhood Program. Projected program savings were provided upon program completion but it was unknown how effective the program was at actually reducing energy consumption in the homes that were upgraded. The following research report uses a PRISM analysis to remove the effect of weather and compare the actual pre and post utility usage rates to determine the actual effectiveness of the program. The housing characteristics, and individual energy upgrades were analyzed to see if any patterns or trends could be identified between consumption savings and housing type and specific upgrade measure. The results of the study showed that the program did induce savings but by much less than the engineering estimates predicted. It is likely that housing characteristics and upgrade measures play a role in inducing consumption savings but homeowner behavior is a stronger factor that influences savings.
Practical Considerations of Waste Heat Reuse for a Mars Mission Advanced Life Support System
NASA Technical Reports Server (NTRS)
Levri, Julie; Finn, Cory; Luna, Bernadette (Technical Monitor)
2000-01-01
Energy conservation is a key issue in design optimization of Advanced Life Support Systems (ALSS) for long-term space missions. By considering designs for conservation at the system level, energy saving opportunities arise that would otherwise go unnoticed. This paper builds on a steady-state investigation of system-level waste heat reuse in an ALSS with a low degree of crop growth for a Mars mission. In past studies, such a system has been defined in terms of technology types, hot and cold stream identification and stream energy content. The maximum steady-state potential for power and cooling savings within the system was computed via the Pinch Method. In this paper, several practical issues are considered for achieving a pragmatic estimate of total system savings in terms of equivalent system mass (ESM), rather than savings solely in terms of power and cooling. In this paper, more realistic ESM savings are computed by considering heat transfer inefficiencies during material transfer. An estimate of the steady-state mass, volume and crewtime requirements associated with heat exchange equipment is made by considering heat exchange equipment material type and configuration, stream flow characteristics and associated energy losses during the heat exchange process. Also, previously estimated power and cooling savings are adjusted to reflect the impact of such energy losses. This paper goes one step further than the traditional Pinch Method of considering waste heat reuse in heat exchangers to include ESM savings that occur with direct reuse of a stream. For example, rather than exchanging heat between crop growth lamp cooling air and air going to a clothes dryer, air used to cool crop lamps might be reused directly for clothes drying purposes. When thermodynamically feasible, such an approach may increase ESM savings by minimizing the mass, volume and crewtime requirements associated with stream routing equipment.
Kim, Y; Kim, H; Hong, Y-C
2016-04-01
Concerns of a growing obesity epidemic have increased since the association between obesity in parents and that in offspring was reported. However, the evidence regarding whether the energy-saving efficiency of obese parents is conveyed to their offspring and the duration of the expression of such transmitted efficiency is limited. We included 7647 matching sets of parent-offspring trios from South Korea. Multiple linear regression models were performed to estimate the energy-saving efficiency, as assessed by the associations between energy intake and obesity-related indices (waist-to-height ratio, waist circumference and body mass index z-score), and to compare the energy-saving efficiency of offspring of obese and non-obese parents. All analyses were based on a complex sample design and were stratified by gender and age. We identified a parental influence on obesity, that is, the more obese the parent, the higher the obesity-related indices of their offspring, in both genders and all age groups. The energy-saving efficiency of child offspring was highest when both parents were obese and lowest when both were non-obese; this difference was significant (P<0.05) with regard to the energy-saving efficiency of all types of intake studied, except fat. However, the energy-saving efficiency of obese and non-obese parents did not differ when their offspring were adolescents and adults. The critical window for transmission of energy-saving efficiency is limited to childhood. These findings suggest that children of obese parents should be more emphatically advised to maintain a balanced diet and to engage in regular physical activity.
Phase 1 of the near term hybrid passenger vehicle development program
NASA Technical Reports Server (NTRS)
Montalenti, P.; Piccolo, R.
1979-01-01
In order to meet project requirements and be competitive in the 1985 market, the proposed six-passenger vehicle incorporates a high power type Ni-Zn battery, which by making electric-only traction possible, permits the achievement of an optimized control strategy based on electric-only traction to a set battery depth of discharge, followed by hybrid operation with thermal primary energy. This results in a highly efficient hybrid propulsion subsystem. Technical solutions are available to contain energy waste by reducing vehicle weight, rolling resistance, and drag coefficient. Reproaching new 1985 full size vehicles of the conventional type with hybrids of the proposed type would result in a U.S. average gasoline saving per vehicle of 1,261 liters/year and an average energy saving per vehicle of 27,133 MJ/year.
Mission aware energy saving strategies for Army ground vehicles
NASA Astrophysics Data System (ADS)
Dattathreya, Macam S.
Fuel energy is a basic necessity for this planet and the modern technology to perform many activities on earth. On the other hand, quadrupled automotive vehicle usage by the commercial industry and military has increased fuel consumption. Military readiness of Army ground vehicles is very important for a country to protect its people and resources. Fuel energy is a major requirement for Army ground vehicles. According to a report, a department of defense has spent nearly $13.6 billion on fuel and electricity to conduct ground missions. On the contrary, energy availability on this plant is slowly decreasing. Therefore, saving energy in Army ground vehicles is very important. Army ground vehicles are embedded with numerous electronic systems to conduct missions such as silent and normal stationary surveillance missions. Increasing electrical energy consumption of these systems is influencing higher fuel consumption of the vehicle. To save energy, the vehicles can use any of the existing techniques, but they require complex, expensive, and time consuming implementations. Therefore, cheaper and simpler approaches are required. In addition, the solutions have to save energy according to mission needs and also overcome size and weight constraints of the vehicle. Existing research in the current literature do not have any mission aware approaches to save energy. This dissertation research proposes mission aware online energy saving strategies for stationary Army ground vehicles to save energy as well as to meet the electrical needs of the vehicle during surveillance missions. The research also proposes theoretical models of surveillance missions, fuzzy logic models of engine and alternator efficiency data, and fuzzy logic algorithms. Based on these models, two energy saving strategies are proposed for silent and normal surveillance type of missions. During silent mission, the engine is on and batteries power the systems. During normal surveillance mission, the engine is on, gear is on neutral position, the vehicle is stationary, and the alternator powers the systems. The proposed energy saving strategy for silent surveillance mission minimizes unnecessary battery discharges by controlling the power states of systems according to the mission needs and available battery capacity. Initial experiments show that the proposed approach saves 3% energy when compared with the baseline strategy for one scenario and 1.8% for the second scenario. The proposed energy saving strategy for normal surveillance mission operates the engine at fuel-efficient speeds to meet vehicle demand and to save fuel. The experiment and simulation uses a computerized vehicle model and a test bench to validate the approach. In comparison to vehicles with fixed high-idle engine speed increments, experiments show that the proposed strategy saves fuel energy in the range of 0-4.9% for the tested power demand range of 44-69 kW. It is hoped to implement the proposed strategies on a real Army ground vehicle to start realizing the energy savings.
Evaluation of an LED Retrofit Project at Princeton University’s Carl Icahn Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Robert G.; Murphy, Arthur L.; Perrin, Tess E.
The LED lighting retrofit at the Carl Icahn Laboratory of the Lewis-Sigler Institute for Integrative Genomics was the first building-wide interior LED project at Princeton University, following the University’s experiences from several years of exterior and small-scale interior LED implementation projects. The project addressed three luminaire types – recessed 2x2 troffers, cove and other luminaires using linear T8 fluorescent lamps, and CFL downlights - which combined accounted for over 564,000 kWh of annual energy, over 90% of the lighting energy used in the facility. The Princeton Facilities Engineering staff used a thorough process of evaluating product alternatives before selecting anmore » acceptable LED retrofit solution for each luminaire type. Overall, 815 2x2 luminaires, 550 linear fluorescent luminaires, and 240 downlights were converted to LED as part of this project. Based solely on the reductions in wattage in converting from the incumbent fluorescent lamps to LED retrofit kits, the annual energy savings from the project was over 190,000 kWh, a savings of 37%. An additional 125,000 kWh of energy savings is expected from the implementation of occupancy and task-tuning control solutions, which will bring the total savings for the project to 62%.« less
NASA Astrophysics Data System (ADS)
Fedorczak-Cisak, Malgorzata; Kwasnowski, Pawel; Furtak, Marcin; Hayduk, Grzegorz
2017-10-01
Experimental buildings for “in situ” research are a very important tool for collecting data on energy efficiency of the energy-saving technologies. One of the most advanced building of this type in Poland is the Maloposkie Laboratory of Energy-saving Buildings at Cracow University of Technology. The building itself is used by scientists as a research object and research tool to test energy-saving technologies. It is equipped with a specialized measuring system consisting of approx. 3 000 different sensors distributed in technical installations and structural elements of the building (walls, ceilings, cornices) and the ground. The authors of the paper will present the innovative design and technology of this specialized instrumentation. They will discuss issues arising during the implementation and use of the building.
Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Bing; Zhang, Jian; Chen, Yan
This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort,more » PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York. Section 2 of this report describes the analysis methodology, including the building types and construction area weights update for this analysis, the baseline, and the method to conduct the energy saving analysis. Section 3 provides detailed specifications of the EEMs and bundles. Section 4 summarizes the results of individual EEMs and EEM bundles by building type, energy end-use and climate zone. Appendix A documents detailed descriptions of the selected prototype buildings. Appendix B provides energy end-use breakdown results by building type for both the baseline code and stretch code in all climate zones.« less
Development of energy saving automatic air conditioner
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okada, T.; Iijima, T.; Kakinuma, A.
1986-01-01
This paper discusses an automatic air conditioner which adopts a new energy saving control method for controlling heat exchange at the heater and the cooler instead of the conventional reheat air-mix one. In this new air conditioner, the cooler does not work when the passenger room is heated and similarly the heater does not work when the passenger room is cooled, minimizing the use rate of the cooler which accounts for the most of the air conditioner's power consumption. Nonetheless, the heat released from the air conditioner to the room can be adjusted smoothly from maximum cooling to maximum heatingmore » just the same as in the conventional type. The results of on-vehicle comparison tests of the above two methods have shown that the energy saving control method saves nearly half of the energy which is consumed in a year with the conventional one, with the room being kept around 25/sup 0/C (77/sup 0/F).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.
The US Department of Energy’s most recent commercial energy code compliance evaluation efforts focused on determining a percent compliance rating for states to help them meet requirements under the American Recovery and Reinvestment Act (ARRA) of 2009. That approach included a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. With its binary approach to compliance determination, the previous methodology failed to answer some important questions. In particular, how much energy cost could be saved by better compliance with the commercial energymore » code and what are the relative priorities of code requirements from an energy cost savings perspective? This paper explores an analytical approach and pilot study using a single building type and climate zone to answer those questions.« less
Comparison of Software Models for Energy Savings from Cool Roofs
DOE Office of Scientific and Technical Information (OSTI.GOV)
New, Joshua Ryan; Miller, William A; Huang, Yu
2014-01-01
A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs modern web technologies, usability design, and national average defaults as an interface to annual simulations of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim in order to provide estimated annual energy and cost savings. In addition to cool reflective roofs, RSC simulates multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roofmore » surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. A base case and energy-efficient alternative can be compared side-by-side to estimate monthly energy. RSC was benchmarked against field data from demonstration homes in Ft. Irwin, California; while cooling savings were similar, heating penalty varied significantly across different simulation engines. RSC results reduce cool roofing cost-effectiveness thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC s projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus, and presents preliminary analyses. RSC s algorithms for capturing radiant heat transfer and duct interaction in the attic assembly are considered major contributing factors to increased cooling savings and heating penalties. Comparison to previous simulation-based studies, analysis on the force multiplier of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model are included.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westervelt, E.T.; Northup, G.R.; Lawrie, L.K.
1990-09-01
This report describes the data analysis and recommendations of a project demonstrating the energy performance of theoretically based retrofit packages on existing standard Army building at Fort Carson, CO. Four standard designs were investigated: a motor vehicle repair shop, the Type 64 (L-shaped) barracks, an enlisted personnel mess hall, and a two-company, rolling-pin-shaped barracks for enlisted personnel. The tested conservation measures included envelope and system modifications. Energy data were gathered and analyzed from 14 buildings. Based on measured savings and current costs of fuel and construction, none of the four original packages are life-cycle cost-effective at present, but two maymore » become effective in the near future. Of higher priority for energy and cost savings is the improvement of building operations, in particular heat production and distribution systems, which lack efficiency and control. Followup work at the L-shaped barracks yielded substantial savings, with a saving-to-investment ration of 5 to 1. Cost scenarios, energy models, and building were developed for the original retrofits to assess applicability elsewhere and in the future.« less
NASA Astrophysics Data System (ADS)
Guo, Fei
The buildings sector is the largest energy-consuming sector in the world. Residential buildings consume about three-quarters of the final energy in the buildings sector. Promoting residential energy savings is in consequence critical for addressing many energy-use-related environmental challenges, such as climate change and air pollution. Given China's robust economic growth and fast urbanization, it is now a critical time to develop policy interventions on residential energy use in the nation. With this as a background, this dissertation explores effective policy intervention opportunities in southern China through analyzing the residential energy-saving potential, using the city of Xiamen as a case study. Four types of residential energy-saving potential are analyzed: technical potential, economic potential, maximum achievable potential (MAP), and possible achievable potential (PAP). Of these, the first two types are characterized as static theoretical evaluation, while the last two represent dynamic evaluation within a certain time horizon. The achievable potential analyses are rarely seen in existing literature. The analytical results reveal that there exists a significant technical potential for residential energy savings of about 20.9-24.9% in the city of Xiamen. Of the technical potential, about two-thirds to four-fifths are cost-effective from the government or society perspective. The cost-effectiveness is evaluated by comparing the "Levelized Cost of Conserved Energy (LCOCE)" of available advanced technical measures with the "Actual Cost" of conserved energy. The "Actual Cost" of energy is defined by adding the environmental externalities costs and hidden government subsidies over the retail prices of energy. The achievable potential analyses are particularly based on two key realistic factors: 1) the gradual ramping-up adoption process of advanced technical measures; and 2) individuals' adoption-decision making on them. For implementing the achievable potential analyses in Xiamen, a residential energy consumption (REC) projection model specifically tailored for southern China is developed. This computational model builds on the Kastovich (1982) adoption-decision theory and the general logic used in the U.S. EIA's (2003) National Energy Modeling System (NEMS). Base on this projection model, Xiamen's REC from the base year 2011 to 2020 is projected. This model can be used as a policy analysis tool to quantitatively evaluate the real-world impact of diverse policy incentives on residential energy use in southern China. The projection results show that the MAP of residential energy savings in Xiamen will be about only 8.3-8.4% in 2020 from a business-as-usual projection. Ten current appropriate and feasible policy interventions are evaluated for analyzing the PAP in Xiamen, which reveals that only about one-fourth to one-half of Xiamen's MAP will possibly be achieved in 2020. Based on the potential analysis for the Xiamen case, a discussion on promoting energy-saving incentive policies for the residential buildings in southern China is given. It suggests that more new, innovative and market-based policies need to be introduced in China in order to realize larger achievable potential for residential energy savings.
Central Plant Optimization for Waste Energy Reduction (CPOWER). ESTCP Cost and Performance Report
2016-12-01
in the regression models. The solar radiation data did not appear reliable in the weather dataset for the location, and hence it was not used. The...and additional factors (e.g., solar insolation) may be needed to obtain a better model. 2. Inputs to optimizer: During several periods of...Location: North Carolina Energy Consumption Cost Savings $ 443,698.00 Analysis Type: FEMP PV of total savings 215,698.00$ Base Date: April 1
NASA Astrophysics Data System (ADS)
Vakulenko, Ihor; Myroshnychenko, Iuliia
2015-12-01
The research is devoted to the problem of the assessment of the integrated projects investment efficiency, energy saving and energy efficiency measures for social and municipal buildings within the course aimed at the reduction of the natural gas consumption and its replacement by alternative fuel types, that is important for a number of European countries, and Ukraine in particular. The objectives of the research are as follows: comparative assessment of the quality of integrated and element-by-element approaches to energy saving encompassing investment, environmental, social and organizational aspects; the formulation of practical recommendations to improve the efficiency of development and implementation of integrated programs in the field of energy saving and energy efficiency. It is proposed to use the methodology of system analysis with the elements of deduction that is practical and that allows to set key factors that influence the processes of energy replacement and energy efficiency increase, as well as factors that constrain them.
Lighting in Commercial Buildings
2009-01-01
Lighting is a major consumer of electricity in commercial buildings and a target for energy savings through use of energy-efficient light sources along with other advanced lighting technologies. The Commercial Buildings Energy Consumption Survey (CBECS) collects information on types of lighting equipment, the amount of floorspace that is lit, and the percentage of floorspace lit by each type. In addition, CBECS data are used to model end-use consumption, including energy consumed for lighting in commercial buildings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konopacki, S.; Akbari, H.
2000-03-01
In 1997, the US Environmental Protection Agency (EPA) established the ''Heat Island Reduction Initiative'', to quantify the potential benefits of Heat Island Reduction (HIR) strategies (i.e., shade trees, reflective roofs, reflective pavements and urban vegetation) to reduce cooling energy use in buildings, lower the ambient air temperature and improve urban air quality in cities, and reduce CO2 emissions from power plants. Under this initiative, the Urban Heat Island Pilot Project (UHIPP) was created with the objective to investigate the potential of HIR strategies in residential and commercial buildings in three initial UHIPP cities: Baton Rouge, Sacramento and Salt Lake City.more » This paper summarizes our efforts to calculate the annual energy savings, peak power avoidance and annual C02 reduction of HIR strategies in the three initial cities. In this analysis, we focused on three building types that offer most savings potential: single-family residence, office and retail store. Each building type was characterized in detail by old or new construction and with a gas furnace or an electric heat pump. We defined prototypical building characteristics for each building type and simulated the impact of HIR strategies on building cooling and heating energy use and peak power demand using the DOE-2.IE model. Our simulations included the impact of (1) strategically-placed shade trees near buildings [direct effect], (2) use of high-albedo roofing material on building [direct effect], (3) combined strategies I and 2 [direct effect], (4) urban reforestation with high-albedo pavements and building surfaces [indirect effect] and (5) combined strategies 1, 2 and 4 [direct and indirect effects]. We then estimated the total roof area of air-conditioned buildings in each city using readily obtainable data to calculate the metropolitan-wide impact of HIR strategies. The results show, that in Baton Rouge, potential annual energy savings of $15M could be realized by rate-payers from the combined direct and indirect effects of HIR strategies. Additionally, peak power avoidance is estimated at 133 MW and the reduction in annual carbon emissions at 41 kt. In Sacramento, the potential annual energy savings is estimated at $26M, with an avoidance of 486 MW in peak power and a reduction in annual carbon of 92 kt. In Salt Lake City, the potential annual energy savings is estimated at $4M, with an avoidance of 85 MW in peak power and a reduction in annual carbon of 20 kt.« less
Research Advances on Fabricated Shear Wall System
NASA Astrophysics Data System (ADS)
Liu, Xudong; Wang, Donghui; Wang, Sheng; Zhai, Yu
2018-03-01
With the rapid development of the construction industry, building energy consumption has been increasing, has become a problem that can not be ignored. It is imperative to develop energy-saving buildings. A new type of prefabricated shear wall is assembled and partially assembled by prefabricated parts, and some concrete is spliced together. The new structure has good integrity, seismic resistance and excellent energy saving and environmental protection performance. It reduces building energy consumption to a great extent. Therefore, the design method, manufacturing process, site assembly process and key technical problems of the system are discussed. For the construction industry gradually entered the energy conservation, environmental protection, safety and durability of sustainable development laid the foundation.
The impact of translucent fabric shades and control strategies on energy savings and visual quality
NASA Astrophysics Data System (ADS)
Wankanapon, Pimonmart
Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric shade colors. The results clearly show the benefit of automatic shade control strategies with integrated lighting control over a condition when shades are closed all day. The main contributor to the total energy savings is from lighting energy savings, followed by cooling energy savings. Shades provide greater benefit in a hot climate and in a moderate climate than in a cold climate. Different control strategies provide savings in the range of 7-35% for annual total space energy with higher savings with light colored shades. Control strategies of shades should be selected and optimized based on climate, orientation, window area, and window/shade properties. High performance glazings, when equipped with shades, show lower energy savings when compared to standard glazings. High transmittance/reflectance shades, such as white shades, perform better than dark shades in most of the cases due to higher lighting energy savings obtained with the automatic electric lighting control and the resulting cooling energy savings from rejection of some solar energy and a reduction in the heat from lights. A South orientation showed the least benefit of automatic control of shades when compare to other orientations due to the large fraction of time shades are required to provide visual comfort. Under automatic shade control, energy savings are higher the more often the shades can be raised. The different automatic control strategies present tradeoffs between energy savings and comfort. With regard to visual quality, daylight quality assessments on view, glare, luminance ratios, and UDI can be used to assess shade control strategies. Automatic shade control can increase the number of view hours while controlling sunlight penetration. With automatic shade control, more daylight hours can be provided within the beneficial range of 100-2000 lux compared to shades that are closed all day. For a person facing the window, discomfort glare is likely to increase the more often the shades are raised. Keeping the shades down ensures an acceptable glare condition, but limits energy savings. Luminance ratios are another metric that can be used to assess shade performance. With white shades, the luminance ratios between the task and proximate surfaces are improved. Dark shades help improve the luminance ratios between the task and distant surfaces. When the shades are left open, even with no direct sunlight in the space, task to window luminance ratios will often exceed 1:10.
Comparison of software models for energy savings from cool roofs
New, Joshua; Miller, William A.; Huang, Yu; ...
2015-06-07
For this study, a web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. RSC simulates multiple roof and attic technologies for side-by-side comparison including reflective roofs, different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. Annual simulations of hour-by-hour, whole-building performance are used to provide estimated annual energy and cost savings from reduced HVAC use. While RSC reported similar cooling savingsmore » to other simulation engines, heating penalty varied significantly. RSC results show reduced cool roofing cost-effectiveness, thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC's projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus. Also included are comparisons to previous simulation-based studies, analysis of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model. Finally, radiant heat transfer and duct interaction not previously modeled is considered a major contributor to heating penalties.« less
Energy Saving in DC Electric Railways by Battery Substation
NASA Astrophysics Data System (ADS)
Sugimoto, Takeshi
New rolling vehicles used in dc electric railways are of the regenerative type. At less busy time a part of regenerative power is not used for powering vehicles, and canceled by changed air brake. Recently, significant attention has been paid to the development of secondary batteries for hybrid and electric motorcars. The use of this battery enables reduction in electric power consumption. Because we can charge excess regenerative power and use for powering vehicles after. Before the fact we compared the actual and simulated effective coefficient of regenerative energy, we confirmed the suitability of the simulation model. In this simulation, we studied the energy-saving effect of the battery substations and determined the battery capacity at which maximum power saving is achieved. We found that the power consumption could be reduced remarkably by using a 15-20kWh battery substation.
Designing effective incentives for energy conservation in the public sector
NASA Astrophysics Data System (ADS)
Drezner, Jeffrey Alan
Understanding why government officials behave in certain ways under particular circumstances is an important theme in political science. This research explores the design of policies and incentives targeted at public sector officials, in particular the use of market based policy tools in a non-market environment, and the influence of that organizational environment on the effectiveness of the policy. The research examines the case of Department of Defense (DoD) facility energy management. DoD energy policy includes a provision for the retention of savings generated by conservation activities: two-thirds of the savings is retained at the installation generating the savings, half to used for further investment in energy conservation, and half to be used for general morale, welfare, and recreation activities. This policy creates a financial incentive for installation energy managers to establish higher quality and more active conservation programs. A formal written survey of installation energy managers within DoD was conducted, providing data to test hypotheses regarding policy effectiveness and factors affecting policy implementation. Additionally, two detailed implementation case studies were conducted in order to gain further insights. Results suggest that policy design needs to account for the environment within which the policy will be implemented, particularly organizational culture and standard operating procedures. The retention of savings policy failed to achieve its intended outcome---retention of savings for re-investment in energy conservation---because the role required of the financial management community was outside its normal mode of operation and interests and the budget process for allocating resources did not include a mechanism for retention of savings. The policy design did not adequately address these start-up barriers to implementation. This analysis has shown that in order for retention of savings, or similar policies based on market-type mechanisms, to be effective in the public sector context, the required cultural changes and appropriate implementing mechanisms must be provided for in the policy design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konopacki, S.; Akbari, H.
2002-02-28
In 1997, the U.S. Environmental Protection Agency (EPA) established the ''Heat Island Reduction Initiative'' to quantify the potential benefits of Heat-Island Reduction (HIR) strategies (i.e., shade trees, reflective roofs, reflective pavements and urban vegetation) to reduce cooling-energy use in buildings, lower the ambient air temperature and improve urban air quality in cities, and reduce CO2 emissions from power plants. Under this initiative, the Urban Heat Island Pilot Project (UHIPP) was created with the objective of investigating the potential of HIR strategies in residential and commercial buildings in three initial UHIPP cities: Baton Rouge, LA; Sacramento, CA; and Salt Lake City,more » UT. Later two other cities, Chicago, IL and Houston, TX were added to the UHIPP. In an earlier report we summarized our efforts to calculate the annual energy savings, peak power avoidance, and annual CO2 reduction obtainable from the introduction of HIR strategies in the initial three cities. This report summarizes the results of our study for Chicago and Houston. In this analysis, we focused on three building types that offer the highest potential savings: single-family residence, office and retail store. Each building type was characterized in detail by vintage and system type (i.e., old and new building constructions, and gas and electric heat). We used the prototypical building characteristics developed earlier for each building type and simulated the impact of HIR strategies on building cooling- and heating-energy use and peak power demand using the DOE-2.1E model. Our simulations included the impact of (1) strategically-placed shade trees near buildings [direct effect], (2) use of high-albedo roofing material on the building [direct effect], (3) urban reforestation with high-albedo pavements and building surfaces [indirect effect] and (4) combined strategies 1, 2, and 3 [direct and indirect effects]. We then estimated the total roof area of air-conditioned buildings in each city using readily obtainable data to calculate the metropolitan-wide impact of HIR strategies. The results show that in Chicago, potential annual energy savings of $30M could be realized by ratepayers from the combined direct and indirect effects of HIR strategies. Additionally, peak power avoidance is estimated at 400 MW and the reduction in annual carbon emissions at 58 ktC. In Houston, the potential annual energy savings are estimated at $82M, with an avoidance of 730 MW in peak power and a reduction in annual carbon emissions of 170 ktC.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2011-09-01
This report covers an assessment of 182 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, description of technical maturity, description of non-energy benefits, description of current barriers for market adoption, and description of the technology’s applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.
New Manufacturing Method for Paper Filler and Fiber Material
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doelle, Klaus
2013-08-25
The use of fillers in printing and writing papers has become a prerequisite for competing in a global market to reduce the cost of materials. Use of calcium carbonates (ranging from 18% to 30%) as filler is a common practice in the paper industry but the choices of fillers for each type of papers vary widely according to its use. The market for uncoated digital printing paper is one that continues to introduce exciting growth projections. and it is important to understand the effect that new manufacturing methods of calcium carbonates have on the energy efficiency and paper production. Research conducted under this award showed that the new fiber filler composite material has the potential to increase the paper filler content by up to 5% without losing mechanical properties. Benefits of the technology can be summarized as follows for a 1% filler increase per metric ton of paper produced: (i) production cost savings overmore » $$12, (ii) Energy savings of 100,900 btu, (iii) CO{sub 2} emission savings of 33 lbs, and additional savings for wood preparation, pulping, recovery of 203593 btu with a 46lbs of CO{sub 2} emission savings per 1% filler increase. In addition the technology has the potential to save: (i) additional $$3 per ton of bleached pulp produced, (ii) bleaching energy savings of 170,000 btu, (iii) bleaching CO{sub 2} emission savings of 39 lbs, and (iv) additional savings for replacing conventional bleaching chemicals with a sustainable bleaching chemical is estimated to be 900,000 btu with a 205 lbs of CO{sub 2} emission savings per ton of bleached pulp produced. All the above translates to a estimated annual savings for a 12% filler increase of 296 trillion buts or 51 million barrel of oil equivalent (BOE) or 13.7% of the industries energy demand. This can lead to a increase of renewable energy usage from 56% to close to 70% for the industry sector. CO{sub 2} emission of the industry at a 12% filler increase could be lowered by over 39 million tons annually. If the new technology could be implemented for bleaching process a total annual estimated energy savings potential of 64 trillion buts or 11 million barrel of oil equivalent (BOE) equal to 3% of the paper industries energy demand could be realized. This could lead to a increase of renewable energy usage from 56% to close to 60% for the industry. CO{sub 2} emissions could be lowered by over 7.4 million tons annually. It is estimated that an installed system could also yield a 75 to 100% return of investment (ROI) rate for the capital equipment that need to be installed for the fiber filler composite manufacturing process.« less
Industrial demand side management: A status report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hopkins, M.F.; Conger, R.L.; Foley, T.J.
This report provides an overview of and rationale for industrial demand side management (DSM) programs. Benefits and barriers are described, and data from the Manufacturing Energy Consumption Survey are used to estimate potential energy savings in kilowatt hours. The report presents types and examples of programs and explores elements of successful programs. Two in-depth case studies (from Boise Cascade and Eli Lilly and Company) illustrate two types of effective DSM programs. Interviews with staff from state public utility commissions indicate the current thinking about the status and future of industrial DSM programs. A comprehensive bibliography is included, technical assistance programsmore » are listed and described, and a methodology for evaluating potential or actual savings from projects is delineated.« less
Moonlight project promotes energy-saving technology
NASA Astrophysics Data System (ADS)
Ishihara, A.
1986-01-01
In promoting energy saving, development of energy conservation technologies aimed at raising energy efficiency in the fields of energy conversion, its transportation, its storage, and its consumption is considered, along with enactment of legal actions urging rational use of energies and implementation of an enlightenment campaign for energy conservation to play a crucial role. Under the Moonlight Project, technical development is at present being centered around the following six pillars: (1) large scale energy saving technology; (2) pioneering and fundamental energy saving technology; (3) international cooperative research project; (4) research and survey of energy saving technology; (5) energy saving technology development by private industry; and (6) promotion of energy saving through standardization. Heat pumps, magnetohydrodynamic generators and fuel cells are discussed.
Chinese hotel general managers' perspectives on energy-saving practices
NASA Astrophysics Data System (ADS)
Zhu, Yidan
As hotels' concern about sustainability and budget-control is growing steadily, energy-saving issues have become one of the important management concerns hospitality industry face. By executing proper energy-saving practices, previous scholars believed that hotel operation costs can decrease dramatically. Moreover, they believed that conducting energy-saving practices may eventually help the hotel to gain other benefits such as an improved reputation and stronger competitive advantage. The energy-saving issue also has become a critical management problem for the hotel industry in China. Previous research has not investigated energy-saving in China's hotel segment. To achieve a better understanding of the importance of energy-saving, this document attempts to present some insights into China's energy-saving practices in the tourist accommodations sector. Results of the study show the Chinese general managers' attitudes toward energy-saving issues and the differences among the diverse hotel managers who responded to the study. Study results indicate that in China, most of the hotels' energy bills decrease due to the implementation of energy-saving equipments. General managers of hotels in operation for a shorter period of time are typically responsible for making decisions about energy-saving issues; older hotels are used to choosing corporate level concerning to this issue. Larger Chinese hotels generally have official energy-saving usage training sessions for employees, but smaller Chinese hotels sometimes overlook the importance of employee training. The study also found that for the Chinese hospitality industry, energy-saving practices related to electricity are the most efficient and common way to save energy, but older hotels also should pay attention to other ways of saving energy such as water conservation or heating/cooling system.
Energy saving and consumption reducing evaluation of thermal power plant
NASA Astrophysics Data System (ADS)
Tan, Xiu; Han, Miaomiao
2018-03-01
At present, energy saving and consumption reduction require energy saving and consumption reduction measures for thermal power plant, establishing an evaluation system for energy conservation and consumption reduction is instructive for the whole energy saving work of thermal power plant. By analysing the existing evaluation system of energy conservation and consumption reduction, this paper points out that in addition to the technical indicators of power plant, market activities should also be introduced in the evaluation of energy saving and consumption reduction in power plant. Ttherefore, a new evaluation index of energy saving and consumption reduction is set up and the example power plant is calculated in this paper. Rresults show that after introducing the new evaluation index of energy saving and consumption reduction, the energy saving effect of the power plant can be judged more comprehensively, so as to better guide the work of energy saving and consumption reduction in power plant.
NASA Astrophysics Data System (ADS)
Polosin, A. N.; Chistyakova, T. B.
2018-05-01
In this article, the authors describe mathematical modeling of polymer processing in extruders of various types used in extrusion and calender productions of film materials. The method consists of the synthesis of a static model for calculating throughput, energy consumption of the extruder, extrudate quality indices, as well as a dynamic model for evaluating polymer residence time in the extruder, on which the quality indices depend. Models are adjusted according to the extruder type (single-screw, reciprocating, twin-screw), its screw and head configuration, extruder’s work temperature conditions, and the processed polymer type. Models enable creating extruder screw configurations and determining extruder controlling action values that provide the extrudate of required quality while satisfying extruder throughput and energy consumption requirements. Model adequacy has been verified using polyolefins’ and polyvinylchloride processing data in different extruders. The program complex, based on mathematical models, has been developed in order to control extruders of various types in order to ensure resource and energy saving in multi-assortment productions of polymeric films. Using the program complex in the control system for the extrusion stage of the polymeric film productions enables improving film quality, reducing spoilage, lessening the time required for production line change-over to other throughput and film type assignment.
Reported Energy and Cost Savings from the DOE ESPC Program: FY 2014
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slattery, Bob S.
2015-03-01
The objective of this work was to determine the realization rate of energy and cost savings from the Department of Energy’s Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 156 Measurement and Verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year. Because the quality of the reports varied, it was not possible to determine all of these parameters for each project. For all 156 projects, theremore » was sufficient information to compare estimated, reported, and guaranteed cost savings. For this group, the total estimated cost savings for the reporting periods addressed were $210.6 million, total reported cost savings were $215.1 million, and total guaranteed cost savings were $204.5 million. This means that on average: ESPC contractors guaranteed 97% of the estimated cost savings; projects reported achieving 102% of the estimated cost savings; and projects reported achieving 105% of the guaranteed cost savings. For 155 of the projects examined, there was sufficient information to compare estimated and reported energy savings. On the basis of site energy, estimated savings for those projects for the previous year totaled 11.938 million MMBtu, and reported savings were 12.138 million MMBtu, 101.7% of the estimated energy savings. On the basis of source energy, total estimated energy savings for the 155 projects were 19.052 million MMBtu, and reported saving were 19.516 million MMBtu, 102.4% of the estimated energy savings.« less
Strategies to Save 50% Site Energy in Grocery and General Merchandise Stores
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirsch, A.; Hale, E.; Leach, M.
2011-03-01
This paper summarizes the methodology and main results of two recently published Technical Support Documents. These reports explore the feasibility of designing general merchandise and grocery stores that use half the energy of a minimally code-compliant building, as measured on a whole-building basis. We used an optimization algorithm to trace out a minimum cost curve and identify designs that satisfy the 50% energy savings goal. We started from baseline building energy use and progressed to more energy-efficient designs by sequentially adding energy design measures (EDMs). Certain EDMs figured prominently in reaching the 50% energy savings goal for both building types:more » (1) reduced lighting power density; (2) optimized area fraction and construction of view glass or skylights, or both, as part of a daylighting system tuned to 46.5 fc (500 lux); (3) reduced infiltration with a main entrance vestibule or an envelope air barrier, or both; and (4) energy recovery ventilators, especially in humid and cold climates. In grocery stores, the most effective EDM, which was chosen for all climates, was replacing baseline medium-temperature refrigerated cases with high-efficiency models that have doors.« less
DEEP: Database of Energy Efficiency Performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Tianzhen; Piette, Mary; Lee, Sang Hoon
A database of energy efficiency performance (DEEP) is a presimulated database to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 10 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER [sic] prototype buildings. The prototype buildings represent seven building types across six vintages of constructions and 16 California climate zones.more » DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air conditioning, plug loads, and domestic hot war. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center (NERSC) of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of the CEC PIER project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users' decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct costly building energy audit.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabine Brueske, Caroline Kramer, Aaron Fisher
2015-06-01
Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. pulp and paper manufacturing. The study relies on multiple sources to estimate the energy used in six individual process areas, representing 52% of sector-wide energy consumption. Energy savings opportunities for individual processes are based on technologies currently in use or under development; the potential savings are then extrapolated to estimate sector-wide energy savings opportunity
Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Petroleum Refining
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabine Brueske, Caroline Kramer, Aaron Fisher
2015-06-01
Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. petroleum refining. The study relies on multiple sources to estimate the energy used in nine individual process areas, representing 68% of sector-wide energy consumption. Energy savings opportunities for individual processes are based on technologies currently in use or under development; these potential savings are then extrapolated to estimate sector-wide energy savings opportunity.
Field Test of Boiler Primary Loop Temperature Controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glanville, P.; Rowley, P.; Schroeder, D.
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belzer, D.; Mosey, G.; Dagher, L.
2008-01-01
Home Performance with ENERGY STAR (HPwES) is a jointly managed program of the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA). This program focuses on improving energy efficiency in existing homes via a whole-house approach to assessing and improving a home's energy performance, and helping to protect the environment. As a local sponsor for HPwES, Austin Energy's HPwES program offers a complete home energy assessment and a list of recommendations for efficiency improvements, along with cost estimates. The owner can choose to implement only one or the complete set of energy conservation measures. Austin Energy facilitatesmore » the process by providing economic incentives to the homeowner through its HPwES Loan program and its HPwES Rebate program. In 2005, the total number of participants in both programs was approximately 1,400. Both programs are only available for improvements made by a participating HPwES contractor. The individual household billing data - encompassing more than 7,000 households - provided by Austin Energy provides a rich data set to estimate the impacts of its HPwES program. The length of the billing histories is sufficient to develop PRISM-type models of electricity use based on several years of monthly bills before and after the installation of the conservation measures. Individual household savings were estimated from a restricted version of a PRISM-type regression model where the reference temperature to define cooling (or heating degree days) was estimated along with other parameters. Because the statistical quality of the regression models varies across individual households, three separate samples were used to measure the aggregate results. The samples were distinguished on the basis of the statistical significance of the estimated (normalized) cooling consumption. A normalized measure of cooling consumption was based on average temperatures observed over the most recent nine-year period ending in 2006. This study provided a statistically rigorous approach to incorporating the variability of expected savings across the households in the sample together with the uncertainty inherent in the regression models used to estimate those savings. While the impact of the regression errors was found to be relatively small in these particular samples, this approach may be useful in future studies using individual household billing data. The median percentage savings for the largest sample of 6,000 households in the analysis was 32%, while the mean savings was 28%. Because the number of households in the sample is very large, the standard error associated with the mean percentage savings are very small, less than 1%. A conservative statement of the average savings is that is falls in the range of 25% to 30% with a high level of certainty. This preliminary analysis provides robust estimates of average program savings, but offers no insight into how savings may vary by type of conservation measure or whether savings vary by the amount of cooling electricity used prior to undertaking the measure. Follow-up researchers may want to analyze the impacts of specific ECMs. Households that use electricity for heating might also be separately analyzed. In potential future work several methodological improvements could also be explored. As mentioned in Section 2, there was no formal attempt to clean the data set of outliers and other abnormal patterns of billing data prior to the statistical analysis. The restriction of a constant reference temperature might also be relaxed. This approach may provide evidence as to whether any 'take-back' efforts are present, whereby thermostat settings are lowered during the summer months after the measures are undertaken (reflected in lower reference temperatures in the post-ECM period). A more extended analysis may also justify the investment in and use of the PRISM software package, which may provide more diagnostic measures with respect to the reference temperature. PRISM also appears to contain some built-in capability to detect outliers and other anomalous data points.« less
A Pottery Electric Kiln Using Decompression
NASA Astrophysics Data System (ADS)
Naoe, Nobuyuki; Yamada, Hirofumi; Nakayama, Tetsuo; Nakayama, Minoru; Minamide, Akiyuki; Takemata, Kazuya
This paper presents a novel type electric kiln which fires the pottery using the decompression. The electric kiln is suitable for the environment and the energy saving as the pottery furnace. This paper described the baking principle and the baking characteristic of the novel type electric kiln.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabine Brueske, Caroline Kramer, Aaron Fisher
Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. chemical manufacturing. The study relies on multiple sources to estimate the energy used in the production of 74 individual chemicals, representing 57% of sector-wide energy consumption. Energy savings opportunities for individual chemicals and for 15 subsectors of chemicals manufacturing are based on technologies currently in use or under development; these potential savings are then extrapolated to estimate sector-wide energy savings opportunity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trumpy, T.
1995-12-01
More efficient use of energy resources can be promoted by various regulatory means, i.e., taxation, subsidies, and pricing. Various incentives can be provided by income and revenue tax breaks-deductible energy audit fees, energy saving investment credits, breaks for energy saving entrepreneurs, and energy savings accounts run through utility accounts. Value added and excise taxes can also be adjusted to reward energy saving investments and energy saving entrepreneurial activity. Incentives can be provided in the form of cash refunds, including trade-in-and-scrap programs and reimbursements or subsidies on audit costs and liability insurance. Pricing incentives include lower rates for less energy use,more » prepayment of deposit related to peak load use, electronically dispatched multiple tariffs, savings credits based on prior peak use, and subsidized {open_quotes}leasing{close_quotes} of more efficient appliances and lights. Credits, with an emphasis on pooling small loans, and 5-year energy savings contracts are also discussed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pelloux-Prayer, D.; Rottenberg, J.; Ours, A.
1982-01-01
Studies have shown that the dry type of condensation boiler offers substantial energy savings in residential space heating. For collective heating, laboratory efficiencies of 85-95% were confirmed in the field by a condensation boiler operating in a 75-unit apartment house. Compared with conventional boilers, the condensation type uses 15-21% less energy. Retrofitting existing boilers involves routing the flue gas through a heat exchanger placed in the return-water system and providing drainage for the condensates.
Consumer behaviours: Teaching children to save energy
NASA Astrophysics Data System (ADS)
Grønhøj, Alice
2016-08-01
Energy-saving programmes are increasingly targeted at children to encourage household energy conservation. A study involving the assignment of energy-saving interventions to Girl Scouts shows that a child-focused intervention can improve energy-saving behaviours among children and their parents.
Energy Savings Lifetimes and Persistence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffman, Ian M.; Schiller, Steven R.; Todd, Annika
2016-02-01
This technical brief explains the concepts of energy savings lifetimes and savings persistence and discusses how program administrators use these factors to calculate savings for efficiency measures, programs and portfolios. Savings lifetime is the length of time that one or more energy efficiency measures or activities save energy, and savings persistence is the change in savings throughout the functional life of a given efficiency measure or activity. Savings lifetimes are essential for assessing the lifecycle benefits and cost effectiveness of efficiency activities and for forecasting loads in resource planning. The brief also provides estimates of savings lifetimes derived from amore » national collection of costs and savings for electric efficiency programs and portfolios.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Charles; Green, Andrew S.; Dahle, Douglas
2013-08-01
The findings of this study indicate that potential exists in non-building applications to save energy and costs. This potential could save billions of federal dollars, reduce reliance on fossil fuels, increase energy independence and security, and reduce greenhouse gas emissions. The Federal Government has nearly twenty years of experience with achieving similar energy cost reductions, and letting the energy costs savings pay for themselves, by applying energy savings performance contracts (ESPC) inits buildings. Currently, the application of ESPCs is limited by statute to federal buildings. This study indicates that ESPCs can be a compatible and effective contracting tool for achievingmore » savings in non-building applications.« less
FY 17 Q1 Commercial integrated heat pump with thermal storage milestone report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abu-Heiba, Ahmad; Baxter, Van D.; Shen, Bo
2017-01-01
The commercial integrated heat pump with thermal storage (AS-IHP) offers significant energy saving over a baseline heat pump with electric water heater. The saving potential is maximized when the AS-IHP serves coincident high water heating and high space cooling demands. A previous energy performance analysis showed that the AS-IHP provides the highest benefit in the hot-humid and hot-dry/mixed dry climate regions. Analysis of technical potential energy savings for these climate zones based on the BTO Market calculator indicated that the following commercial building market segments had the highest water heating loads relative to space cooling and heating loads education, foodmore » service, health care, lodging, and mercantile/service. In this study, we focused on these building types to conservatively estimate the market potential of the AS-IHP. Our analysis estimates maximum annual shipments of ~522,000 units assuming 100% of the total market is captured. An early replacement market based on replacement of systems in target buildings between 15 and 35 years old was estimated at ~136,000 units. Technical potential energy savings are estimated at ~0.27 quad based on the maximum market estimate, equivalent to ~13.9 MM Ton CO2 emissions reduction.« less
NASA Technical Reports Server (NTRS)
Moretti, V. C.; Davis, H. S.; Slonski, M. L.
1978-01-01
In a study sponsored by the State of California Energy Resources Conservation and Development Commission, 12 industrial plants in five utility districts were surveyed to assess the potential applications of the cogeneration of heat and electricity in California industry. Thermodynamic calculations were made for each plant in determining the energy required to meet the existing electrical and steam demands. The present systems were then compared to conceptual cogeneration systems specified for each plant. Overall energy savings were determined for the cogeneration applications. Steam and gas turbine topping cycle systems were considered as well as bottoming cycle systems. Types of industries studied were: pulp and paper, timber, cement, petroleum refining, enhanced oil recovery, foods processing, steel and glass
Grant management procedure for energy saving TDM-PONs
NASA Astrophysics Data System (ADS)
Alaelddin, Fuad Yousif Mohammed; Newaz, S. H. Shah; AL-Hazemi, Fawaz; Choi, Jun Kyun
2018-01-01
In order to minimize energy consumption in Time Division Multiplexing-Passive Optical Network (TDM-PON), IEEE and ITU-T have mandated sleep mode mechanism for Optical Network Units (ONUs) in the latest TDM-PON standards (e.g. IEEE P1904.1 SIEPON, ITU-T G.sup45). The sleep mode mechanism is a promising mean for maximizing energy saving in an ONU. An ONU in sleep mode flips between sleep and active state depending on the presence or absent of upstream and downstream frames. To ensure Quality of Service (QoS) of upstream frames, the recent TDM-PON standards introduced an early wake-up mechanism, in which an ONU is forced to leave the sleep state on upstream frame arrival. When the Optical Line Terminal (OLT) of a TDM-PON allows early wake-up of its connected ONUs, it allocates gratuitous grants for the sleeping ONUs along with allocating upstream grants for the ONUs in active state. Note that, the gratuitous grants control message sent periodically by the OLT on Inter-Gratuitous grant Interval (IGI) time. After leaving sleep state due to the arrival of upstream frame, the ONU uses its allocated gratuitous grant to send a control message mentioning the amount of upstream bandwidth (upstream grant) required in order to forward the remaining frames in its buffer. However, the existing early wake-up process of ONU can lead to increase the energy consumption of an ONU. It is because of the ONU wakes-up immediately from the sleep state on arrival of the upstream frame, but even so, it needs to wait for forwarding the frame until its allocated gratuitous grant period, resulting in spending energy unnecessarily. In addition, current energy saving solution for TDM-PONs do not provide a clear solution on how to manage different types of grants (e.g. listening grant, upstream transmission grant) within a Dynamic Bandwidth Allocation (DBA) polling cycle. To address this problem, we propose a state-of-art Grant Management Procedure (GMP) in order to maximize energy saving in a TDM-PON with sleep mode enabled ONUs. GMP contributes in defining the location of the different types of grants during a DBA polling cycle. Furthermore, GMP devises a mechanism so as to allow an ONU to predict its assigned gratuitous grant control message arrival time, thereby allowing an ONU to remain its transceiver unit powered off until the arrival period of the next gratuitous grant control message, increasing the energy saving of the ONU. Results show that, with the increment of IGI, the energy saving performance of an ONU with GMP increases noticeably in compare to a conventional ONU (an ONU that does not use GMP) without imposing any additional upstream frame delay.
A CLS-based survivable and energy-saving WDM-PON architecture
NASA Astrophysics Data System (ADS)
Zhu, Min; Zhong, Wen-De; Zhang, Zhenrong; Luan, Feng
2013-11-01
We propose and demonstrate an improved survivable and energy-saving WDM-PON with colorless ONUs. It incorporates both energy-saving and self-healing operations. A simple effective energy-saving scheme is proposed by including an energy-saving control unit in the OLT and a control unit at each ONU. The energy-saving scheme realizes both dozing and sleep (offline) modes, which greatly improves the energy-saving efficiency for WDM-PONs. An intelligent protection switching scheme is designed in the OLT, which can distinguish if an ONU is in dozing/sleep (offline) state or a fiber is faulty. Moreover, by monitoring the optical power of each channel on both working and protection paths, the OLT can know the connection status of every fiber path, thus facilitating an effective protection switching and a faster failure recovery. The improved WDM-PON architecture not only significantly reduces energy consumption, but also performs self-healing operation in practical operation scenarios. The scheme feasibility is experimentally verified with 10 Gbit/s downstream and 1.25 Gbit/s upstream transmissions. We also examine the energy-saving efficiency of our proposed energy-saving scheme by simulation, which reveals that energy saving mainly arises from the dozing mode, not from the sleep mode when the ONU is in the online state.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoon Lee, Sang; Hong, Tianzhen; Sawaya, Geof
The paper presents a method and process to establish a database of energy efficiency performance (DEEP) to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 35 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER prototype buildings. The prototype buildings represent seven building types across six vintages of constructions andmore » 16 California climate zones. DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and domestic hot water. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of an on-going project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users’ decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct costly building energy audit. DEEP will be migrated into the DEnCity - DOE’s Energy City, which integrates large-scale energy data for multi-purpose, open, and dynamic database leveraging diverse source of existing simulation data.« less
OpenStudio: A Platform for Ex Ante Incentive Programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, Amir; Brackney, Larry; Parker, Andrew
Many utilities operate programs that provide ex ante (up front) incentives for building energy conservation measures (ECMs). A typical incentive program covers two kinds of ECMs. ECMs that deliver similar savings in different contexts are associated with pre-calculated 'deemed' savings values. ECMs that deliver different savings in different contexts are evaluated on a 'custom' per-project basis. Incentive programs often operate at less than peak efficiency because both deemed ECMs and custom projects have lengthy and effort-intensive review processes--deemed ECMs to gain confidence that they are sufficiently context insensitive, custom projects to ensure that savings are claimed appropriately. DOE's OpenStudio platformmore » can be used to automate ex ante processes and help utilities operate programs more efficiently, consistently, and transparently, resulting in greater project throughput and energy savings. A key concept of the platform is the OpenStudio Measure, a script that queries and transforms building energy models. Measures can be simple or surgical, e.g., applying different transformations based on space-type, orientation, etc. Measures represent ECMs explicitly and are easier to review than ECMs that are represented implicitly as the difference between a with-ECM and without-ECM models. Measures can be automatically applied to large numbers of prototype models--and instantiated from uncertainty distributions--facilitating the large scale analysis required to develop deemed savings values. For custom projects, Measures can also be used to calibrate existing building models, to automatically create code baseline models, and to perform quality assurance screening.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
PARR
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.« less
Biomechanical pulping of aspen chips; Energy savings resulting from different fungal treatments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leatham, G.F.; Myers, G.C.; Wegner, T.H.
1990-05-01
Besides increasing paper strength, fungal treatments can also reduce the electrical energy needed for fiberizing chips during mechanical pulping. Fungal species, chip movement, and treatment duration affected the extent of energy savings. This paper reports that four-week-long treatment with white-rot fungi, including Phlebia species or Pholiota mutabilis, in a stationary wire tray bioreactor resulted in at least 35% energy savings for pulping chips to 100 mL CSF in a 300-mm-diameter disc refiner. With Phanerochaete chrysosporium in a rotating-drum bioreactor, the optimal treatment duration was four weeks. Treatment with a brown-rot fungus also resulted in energy savings. Over the range ofmore » fungi and conditions tested, neither chip weight loss nor lignin loss correlated with energy savings. Some treatments giving the least chip weight loss ({lt}5%) saved the most energy. Wood modifications responsible for energy savings differed from those that increased strength. Treatments that saved the most energy did not necessarily give the highest strength properties.« less
Retrofitting solutions for two different occupancy levels of educational buildings in tropics
NASA Astrophysics Data System (ADS)
Yang, Junjing; Pantazaras, Alexandros; Lee, Siew Eang; Santamouris, Mattheos
2018-01-01
Within the multi-functionality of educational buildings, the energy conservation potential can be very different. In addition, among different retrofitting solutions investigated involving interventions on the building envelope, ventilation strategies, artificial lighting systems as well as equipment upgrading, different saving potential would come from different aspects. The opportunities for energy saving potential from the overall point of view and from the detailed aspect view of different retrofitting solutions would be very useful and important for building renovation decision making. This study presents a detailed retrofitting study of two different educational buildings. One represents a building with average occupancy variation and containing mainly offices and labs. The other one represents a building with high occupancy variation and containing mainly lecture rooms and studios. This comparison of the results gives an idea of the different energy saving potential for different types of educational buildings. Principal component analysis is also adopted to investigate the detailed performance of one of the buildings which is influenced stronger by these retrofitting solutions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerke, Brian F; McNeil, Michael A; Tu, Thomas
A major barrier to effective appliance efficiency program design and evaluation is a lack of data for determination of market baselines and cost-effective energy savings potential. The data gap is particularly acute in developing countries, which may have the greatest savings potential per unit GDP. To address this need, we are developing the International Database of Efficient Appliances (IDEA), which automatically compiles data from a wide variety of online sources to create a unified repository of information on efficiency, price, and features for a wide range of energy-consuming products across global markets. This paper summarizes the database framework and demonstratesmore » the power of IDEA as a resource for appliance efficiency research and policy development. Using IDEA data for refrigerators in China and India, we develop robust cost-effectiveness indicators that allow rapid determination of savings potential within each market, as well as comparison of that potential across markets and appliance types. We discuss implications for future energy efficiency policy development.« less
Expanding Energy Performance Contracting in china: policy solutions and market mechanisms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Bo; Price, Lynn; Liu, Xu
Energy performance contracting is an important market mechanism that uses energy savings to pay over time for the upfront costs of energy efficiency retrofits in buildings, industries, and other types of facilities. Through energy performance contracts (EPCs), Energy Service Companies (ESCOs) play an important role in implementing energy efficiency retrofits. Both China and the United States have large markets for EPCs and significant opportunities for growth. The Chinese government has made great efforts in promoting the country’s ESCO business and expanding its EPC markets. This paper makes a series of recommendations for China to adopt more ambitious policy measures tomore » encourage deep energy savings projects via EPCs. These recommendations are built on initial insights from a white paper developed by researchers at the Pacific Northwest National Laboratory and the Lawrence Berkeley National Laboratory with the assistance from the ESCO Committee of China’s Energy Conservation Association (EMCA). Key recommendations are listed below.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Booth, S.; Doris, E.; Knutson, D.
2011-05-01
Numerous pre-existing and newly emerging state- and locally-managed revolving loan funds (RLFs) are being used in conjunction with energy savings performance contracts (ESPCs) as an option for financing of energy efficiency projects. This document presents an overview of ESPCs and how they fit within the RLF framework. There are a variety of options available to state and local governments to catalyze the disbursement of available capital from RLFs and increase the number of ESPC projects within their jurisdictions. To demonstrate the implementation of this type of financing program in action, this report concludes with four program case studies of state-sponsoredmore » RLFs where ESPCs are an allowed use of funds.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tonn, Bruce Edward; Carroll, David; Rose, Erin M.
2015-10-01
This report presents a summary of the American Recovery and Reinvestment Act of 2009 (ARRA) evaluation of the U.S. Department of Energy s low-income Weatherization Program. This evaluation focused on the WAP Program Year 2010. The ARRA evaluation produced fourteen separate reports, including this summary. Three separate reports address the energy savings, energy cost savings, and cost effectiveness of WAP across four housing types: single family, mobile home, and large multifamily. Other reports address the environmental emissions benefits attributable to WAP, and characterize the program. Special studies were conducted to: estimate the impacts of weatherization and healthy homes interventions onmore » asthma-related Medicaid claims in a small cohort in Washington State; assess how weatherization recipients communicate their weatherization experiences to those in their social network, and assess processes implemented to defer homes for weatherization. Small studies addressed energy use in refrigerators, WAP as implemented in the U.S. territories for the first time, and weatherization s impacts on air conditioning energy savings. The national occupant survey was mined for additional insights on the impacts of weatherization on household budgets and energy behaviors post-weatherization. Lastly, the results of a survey of weatherization training centers are summarized.« less
An Energy Saving System for a Beam Pumping Unit
Lv, Hongqiang; Liu, Jun; Han, Jiuqiang; Jiang, An
2016-01-01
Beam pumping units are widely used in the oil production industry, but the energy efficiency of this artificial lift machinery is generally low, especially for the low-production well and high-production well in the later stage. There are a number of ways for energy savings in pumping units, with the periodic adjustment of stroke speed and rectification of balance deviation being two important methods. In the paper, an energy saving system for a beam pumping unit (ESS-BPU) based on the Internet of Things (IoT) was proposed. A total of four types of sensors, including load sensor, angle sensor, voltage sensor, and current sensor, were used to detect the operating conditions of the pumping unit. Data from these sensors was fed into a controller installed in an oilfield to adjust the stroke speed automatically and estimate the degree of balance in real-time. Additionally, remote supervision could be fulfilled using a browser on a computer or smartphone. Furthermore, the data from a practical application was recorded and analyzed, and it can be seen that ESS-BPU is helpful in reducing energy loss caused by unnecessarily high stroke speed and a poor degree of balance. PMID:27187402
DOE Office of Scientific and Technical Information (OSTI.GOV)
Billingsley, Megan A.; Hoffman, Ian M.; Stuart, Elizabeth
End-use energy efficiency is increasingly being relied upon as a resource for meeting electricity and natural gas utility system needs within the United States. There is a direct connection between the maturation of energy efficiency as a resource and the need for consistent, high-quality data and reporting of efficiency program costs and impacts. To support this effort, LBNL initiated the Cost of Saved Energy Project (CSE Project) and created a Demand-Side Management (DSM) Program Impacts Database to provide a resource for policy makers, regulators, and the efficiency industry as a whole. This study is the first technical report of themore » LBNL CSE Project and provides an overview of the project scope, approach, and initial findings, including: • Providing a proof of concept that the program-level cost and savings data can be collected, organized, and analyzed in a systematic fashion; • Presenting initial program, sector, and portfolio level results for the program administrator CSE for a recent time period (2009-2011); and • Encouraging state and regional entities to establish common reporting definitions and formats that would make the collection and comparison of CSE data more reliable. The LBNL DSM Program Impacts Database includes the program results reported to state regulators by more than 100 program administrators in 31 states, primarily for the years 2009–2011. In total, we have compiled cost and energy savings data on more than 1,700 programs over one or more program-years for a total of more than 4,000 program-years’ worth of data, providing a rich dataset for analyses. We use the information to report costs-per-unit of electricity and natural gas savings for utility customer-funded, end-use energy efficiency programs. The program administrator CSE values are presented at national, state, and regional levels by market sector (e.g., commercial, industrial, residential) and by program type (e.g., residential whole home programs, commercial new construction, commercial/industrial custom rebate programs). In this report, the focus is on gross energy savings and the costs borne by the program administrator—including administration, payments to implementation contractors, marketing, incentives to program participants (end users) and both midstream and upstream trade allies, and evaluation costs. We collected data on net savings and costs incurred by program participants. However, there were insufficient data on participant cost contributions, and uncertainty and variability in the ways in which net savings were reported and defined across states (and program administrators).« less
Energy-Saving Opportunities for Manufacturing Enterprises (International English Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This fact sheet provides information about the Industrial Technologies Program Save Energy Now energy audit process, software tools, training, energy management standards, and energy efficient technologies to help U.S. companies identify energy cost savings.
48 CFR 23.205 - Energy-savings performance contracts.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Energy-savings performance... SOCIOECONOMIC PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Energy and Water Efficiency and Renewable Energy 23.205 Energy-savings...
48 CFR 23.205 - Energy-savings performance contracts.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Energy-savings performance... SOCIOECONOMIC PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Energy and Water Efficiency and Renewable Energy 23.205 Energy-savings...
48 CFR 23.205 - Energy-savings performance contracts.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Energy-savings performance... SOCIOECONOMIC PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Energy and Water Efficiency and Renewable Energy 23.205 Energy-savings...
48 CFR 23.205 - Energy-savings performance contracts.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Energy-savings performance... SOCIOECONOMIC PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Energy and Water Efficiency and Renewable Energy 23.205 Energy-savings...
48 CFR 23.205 - Energy-savings performance contracts.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Energy-savings performance... SOCIOECONOMIC PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Energy and Water Efficiency and Renewable Energy 23.205 Energy-savings...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W; Stern, Frank; Spencer, Justin
Savings from electric energy efficiency measures and programs are often expressed in terms of annual energy and presented as kilowatt-hours per year (kWh/year). However, for a full assessment of the value of these savings, it is usually necessary to consider the measure or program's impact on peak demand as well as time-differentiated energy savings. This cross-cutting protocol describes methods for estimating the peak demand and time-differentiated energy impacts of measures implemented through energy efficiency programs.
EnergySavers: Tips on Saving Money & Energy at Home (Brochure)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The U.S. Department of Energy's consumer guide to saving money and energy at home and on the road. It consists of the following articles: (1) Save Money and Energy Today - Get started with things you can do now, and use the whole-house approach to ensure that your investments are wisely made to save you money and energy; (2) Your Home's Energy Use - Find out how your home uses energy, and where it's losing the most energy so you can develop a plan to save in the short and long term; (3) Air Leaks and Insulation - Seal airmore » leaks and insulate your home properly so your energy dollars don't seep through the cracks; (4) Heating and Cooling - Use efficient systems to heat and cool your home, and save money and increase comfort by properly maintaining and upgrading equipment; (5) Water Heating - Use the right water heater for your home, insulate it and lower its temperature, and use less water to avoid paying too much; (6) Windows - Enjoy light and views while saving money by installing energy-efficient windows, and use strategies to keep your current windows from losing energy; (7) Lighting - Choose today's energy-efficient lighting for some of the easiest and cheapest ways to reduce your electric bill; (8) Appliances - Use efficient appliances through-out your home, and get greater performance with lower energy bills; (9) Home Office and Electronics - Find out how much energy your electronics use, reduce their out-put when you're not using them, and choose efficient electronics to save money; (10) Renewable Energy - Use renewable energy at home such as solar and wind to save energy dollars while reducing environmental impact; (11) Transportation - Choose efficient transportation options and drive more efficiently to save at the gas pump; and (12) References - Use our reference list to learn more about energy efficiency and renewable energy.« less
Baker-Barry Tunnel Lighting: Evaluation of a Potential GATEWAY Demonstrations Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tuenge, Jason R.
2011-06-28
The U.S. Department of Energy is evaluating the Baker-Barry Tunnel as a potential GATEWAY Demonstrations project for deployment of solid-state lighting (SSL) technology. The National Park Service views this project as a possible proving ground and template for implementation of light-emitting diode (LED) luminaires in other tunnels, thereby expanding the estimated 40% energy savings from 132 MWh/yr to a much larger figure nationally. Most of the energy savings in this application is attributable to the instant-restrike capability of LED products and to their high tolerance for frequent on/off switching, used here to separately control either end of the tunnel duringmore » daytime hours. Some LED luminaires rival or outperform their high-intensity discharge (HID) counterparts in terms of efficacy, but options are limited, and smaller lumen packages preclude true one-for-one equivalence. However, LED products continue to improve in efficacy and affordability at a rate unmatched by other light source technologies; the estimated simple payback period of eight years (excluding installation costs and maintenance savings) can be expected to improve with time. The proposed revisions to the existing high-pressure sodium (HPS) lighting system would require slightly increased controls complexity and significantly increased luminaire types and quantities. In exchange, substantial annual savings (from reduced maintenance and energy use) would be complemented by improved quantity and quality of illumination. Although advanced lighting controls could offer additional savings, it is unclear whether such a system would prove cost-effective; this topic may be explored in future work.« less
A SIEPON based transmitter sleep mode energy-efficient mechanism in EPON
NASA Astrophysics Data System (ADS)
Nikoukar, AliAkbar; Hwang, I.-Shyan; Wang, Chien-Jung; Ab-Rahman, Mohammad Syuhaimi; Liem, Andrew Tanny
2015-06-01
The main energy consumption in computer networks is the access networks. The passive optical network (PON) has the least energy consumption among access network technologies. In addition, the time division multiplexing (TDM) Ethernet PON (EPON) is one of the best candidates to improve energy consumption by time utilization. The optical network unit (ONU) can utilize the time and save the energy in the EPON by turning off its transmitter/receiver when there is no upstream/downstream traffic. The ITU-T and IEEE organizations are published standards for energy-saving in the TDM-PON. Although their standards provide the framework to accomplish the energy-saving, the algorithms/criteria to generate events to accommodate various operational policies, time to wake up, parameter values for timers are out of scope of the standards. Many studies have proposed schemes for energy-saving in TDM-PON to achieve maximum energy saving. Even so, these schemes increase the mean packet delay and consequently, reduce the quality of service (QoS). In this paper, first we take a look to the state of the art for PON energy-saving. Additionally, a mechanism based on SIEPON standard in EPON with new components in the ONUs and optical line terminal (OLT) is proposed to save the transmitter energy and guarantee QoS. The proposed mechanism follows the SIEPON standard, considers the QoS first, and then saves the energy as far as possible. The ONU sleep controller unit (OSC) and green dynamic bandwidth allocation (GDBA) are used to calculate the ONU transmitter sleep (Tx) duration and grant the proper time to the ONUs. Simulation results show that the proposed energy-saving mechanism not only promises the QoS performance in terms of mean packet delay, packet loss, throughput, and jitter, but also saves energy in different maximum cycle times.
ACHP | Sustainability and Historic Preservation Links
Energy) Realizing the Energy Efficiency Potential of Small Buildings: Saving Energy, Money and Jobs Improving the Energy Efficiency of Historic Buildings (National Park Service) Saving Windows, Saving Money
ResStock - Targeting Energy and Cost Savings for U.S. Homes | NREL
ResStock - Targeting Energy and Cost Savings for U.S. Homes Science and Technology Highlights Highlights in Research & Development ResStock - Targeting Energy and Cost Savings for U.S. Homes Key discovered $49 billion in potential annual utility bill savings through cost-effective energy efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schipper, L.; Darmstadter, J.
1978-01-01
Energy conservation is seen as a complex mix of economic and moral considerations, which should be applied to specific strategies for changing waste handling, lifestyle, growth, etc., after meaningful payoffs have been researched and identified. The author recommends measuring energy conservation in terms of primary energy resources saved, and evaluating changes in consumption patterns on the basis of indirect as well as direct energy use. He feels consideration should be given to the intensity of energy use as well as to before-and-after comparisons. Human factors and wellbeing need to be included in shifts from energy-intensive to labor-intensive equipment. Curtailment ofmore » energy supplies as a conservation technique is seen as less effective than substitution, changes in habit and attitude, and changes in the types of goods and services demanded. While add-on investments have short-term value, new capital-equipment investments offer greater energy and economic savings in the long run. The author cautions against using strict rules to determine energy efficiency by relating energy to gross national product. Conservation is seen as an economic stimulus when compared to the costs of not conserving. 14 references. (DCK)« less
An energy saving mechanism of EPON networks for real time video transmission
NASA Astrophysics Data System (ADS)
Liu, Chien-Ping; Wu, Ho-Ting; Chiang, Yun-Ting; Chien, Shieh-Chieh; Ke, Kai-Wei
2015-07-01
Modern access networks are constructed widely by passive optical networks (PONs) to meet the growing bandwidth demand. However, higher bandwidth means more energy consumption. To save energy, a few research works propose the dual-mode energy saving mechanism that allows the ONU to operate between active and sleep modes periodically. However, such dual-mode energy saving design may induce unnecessary power consumption or packet delay increase in the case where only downstream data exist for most of the time. In this paper, we propose a new tri-mode energy saving scheme for Ethernet PON (EPON). The new tri-mode energy saving design, combining the dual-mode saving mechanism with the doze mode, allows the ONU to switch among these three modes alternatively. In the doze mode, the ONU may receive downstream data while keeping its transmitter close. Such scenario is often observed for real time video downstream transmission. Furthermore, the low packet delay of high priority upstream data can be attained through the use of early wake-up mechanism employed in both energy saving modes. The energy saving and system efficiency can thus be achieved jointly while maintaining the differentiated QoS for data with various priorities. Performance results via simulation have demonstrated the effectiveness of such mechanism.
ERIC Educational Resources Information Center
American School and University, 1981
1981-01-01
Schools in Wilton (Connecticut) cut electric consumption 39 percent by replacing existing lamps with new types of energy saving lamps. Fuel oil consumption dropped 53 percent largely through attention paid to the operation of boilers and oil burners. (Author/MLF)
Exploring Demand Charge Savings from Commercial Solar
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darghouth, Naim; Barbose, Galen; Mills, Andrew
Commercial retail electricity rates commonly include a demand charge component, based on some measure of the customer’s peak demand. Customer-sited solar PV can potentially reduce demand charges, but the magnitude of these savings can be difficult to predict, given variations in demand charge designs, customer loads, and PV generation profiles. Moreover, depending on the circumstances, demand charges from solar may or may not align well with associated utility cost savings. Lawrence Berkeley National Laboratory (Berkeley Lab) and the National Renewable Energy Laboratory (NREL) are collaborating in a series of studies to understand how solar PV can reduce demand charge levelsmore » for a variety of customer types and demand charges designs. Previous work focused on residential customs with solar. This study, instead, focuses on commercial customers and seeks to understand the extent and conditions under which rooftop can solar reduce commercial demand charges. To answer these questions, we simulate demand charge savings for a broad range of commercial customer types, demand charge designs, locations, and PV system characteristics. This particular analysis does not include storage, but a subsequent analysis in this series will evaluate demand charge savings for commercial customers with solar and storage.« less
NASA Astrophysics Data System (ADS)
Jiang, Yingni
2018-03-01
Due to the high energy consumption of communication, energy saving of data centers must be enforced. But the lack of evaluation mechanisms has restrained the process on energy saving construction of data centers. In this paper, energy saving evaluation index system of data centers was constructed on the basis of clarifying the influence factors. Based on the evaluation index system, analytical hierarchy process was used to determine the weights of the evaluation indexes. Subsequently, a three-grade fuzzy comprehensive evaluation model was constructed to evaluate the energy saving system of data centers.
Insights from Smart Meters: The Potential for Peak-Hour Savings from Behavior-Based Programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todd, Annika; Perry, Michael; Smith, Brian
The rollout of smart meters in the last several years has opened up new forms of previously unavailable energy data. Many utilities are now able in real-time to capture granular, household level interval usage data at very high-frequency levels for a large proportion of their residential and small commercial customer population. This can be linked to other time and locationspecific information, providing vast, constantly growing streams of rich data (sometimes referred to by the recently popular buzz word, “big data”). Within the energy industry there is increasing interest in tapping into the opportunities that these data can provide. What canmore » we do with all of these data? The richness and granularity of these data enable many types of creative and cutting-edge analytics. Technically sophisticated and rigorous statistical techniques can be used to pull interesting insights out of this highfrequency, human-focused data. We at LBNL are calling this “behavior analytics”. This kind of analytics has the potential to provide tremendous value to a wide range of energy programs. For example, highly disaggregated and heterogeneous information about actual energy use would allow energy efficiency (EE) and/or demand response (DR) program implementers to target specific programs to specific households; would enable evaluation, measurement and verification (EM&V) of energy efficiency programs to be performed on a much shorter time horizon than was previously possible; and would provide better insights in to the energy and peak hour savings associated with specifics types of EE and DR programs (e.g., behavior-based (BB) programs). In this series, “Insights from Smart Meters”, we will present concrete, illustrative examples of the type of value that insights from behavior analytics of these data can provide (as well as pointing out its limitations). We will supply several types of key findings, including: • Novel results, which answer questions the industry previously was unable to answer; • Proof-of-concept analytics tools that can be adapted and used by others; and • Guidelines and protocols that summarize analytical best practices. This report focuses on one example of the kind of value that analysis of this data can provide: insights into whether behavior-based (BB) efficiency programs have the potential to provide peak-hour energy savings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This case study describes how the Shaw Industries plant #20 in Dalton, Georgia, achieved annual savings of $872,000 and 93,000 MMBtu after receiving a DOE Save Energy Now energy assessment and implementing recommendations to improve the efficiency of its steam system.
Technical Resources for Energy Savings Plus Health
The Energy Savings Plus Health Guide equips school districts to integrate indoor air quality protections into school energy efficiency retrofits and other building upgrade projects. This page lists additional resources related to Energy Savings Plus Health
Gordon M. Heisler
1991-01-01
Saving energy has recently acquired new importance because of increased concern for dwindling fossil fuel supplies and for the problem of carbon dioxide contributions to global climate change. Many studies have indicated that windbreaks have the ability to save energy for heating buildings. Suggested savings have ranged up 40 percent; though more commonly savings of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W; Violette, Daniel M.; Rathbun, Pamela
This chapter focuses on the methods used to estimate net energy savings in evaluation, measurement, and verification (EM and V) studies for energy efficiency (EE) programs. The chapter provides a definition of net savings, which remains an unsettled topic both within the EE evaluation community and across the broader public policy evaluation community, particularly in the context of attribution of savings to a program. The chapter differs from the measure-specific Uniform Methods Project (UMP) chapters in both its approach and work product. Unlike other UMP resources that provide recommended protocols for determining gross energy savings, this chapter describes and comparesmore » the current industry practices for determining net energy savings but does not prescribe methods.« less
Energy Saver: Tips on Saving Energy and Money in Your Home
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casey, Allison L
This guide shows you how easy it is to reduce your energy use at home and on the road. You'll find quick tips you can use to start saving today, as well as information on larger projects that will help save you money over the long term. Find even more information about saving money and energy at home by visiting our website, EnergySaver.gov.
Saving Money Through Energy Conservation.
ERIC Educational Resources Information Center
Presley, Michael H.; And Others
This publication is an introduction to personal energy conservation. The first chapter presents a rationale for conserving energy and points out that private citizens control about one third of this country's energy consumption. Chapters two and three show how to save money by saving energy. Chapter two discusses energy conservation methods in the…
Energy Cost Impact of Non-Residential Energy Code Requirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jian; Hart, Philip R.; Rosenberg, Michael I.
2016-08-22
The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of themore » probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.« less
Quantifying Behavior Driven Energy Savings for Hotels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Bing; Wang, Na; Hooks, Edward
2016-08-12
Hotel facilities present abundant opportunities for energy savings. In the United States, there are around 25,000 hotels that spend on an average of $2,196 on energy costs per room each year. This amounts to about 6% of the total annual hotel operating cost. However, unlike offices, there are limited studies on establishing appropriate baselines and quantifying hotel energy savings given the variety of services and amenities, unpredictable customer behaviors, and the around-the-clock operation hours. In this study, we investigate behavior driven energy savings for three medium-size (around 90,000 sf2) hotels that offer similar services in different climate zones. We firstmore » used Department of Energy Asset Scoring Tool to establish baseline models. We then conducted energy saving analysis in EnergyPlus based on a behavior model that defines the upper bound and lower bound of customer and hotel staff behavior. Lastly, we presented a probabilistic energy savings outlook for each hotel. The analysis shows behavior driven energy savings up to 25%. We believe this is the first study to incorporate behavioral factors into energy analysis for hotels. It also demonstrates a procedure to quickly create tailored baselines and identify improvement opportunities for hotels.« less
Reducing Operating Costs and Energy Consumption at Water Utilities
Due to their unique combination of high energy usage and potential for significant savings, utilities are turning to energy-efficient technologies to help save money. Learn about cost and energy saving technologies from this brochure.
Eco-efficiency evaluation of a smart window prototype.
Syrrakou, E; Papaefthimiou, S; Yianoulis, P
2006-04-15
An eco-efficiency analysis was conducted using indicators suitably defined to evaluate the performance of an electrochromic window acting as an energy saving component in buildings. Combining the indicators for various parameters (control scenario, expected lifetime, climatic type, purchase cost) significant conclusions are drawn for the development and the potential applications of the device compared to other commercial fenestration products. The reduction of the purchase cost (to 200 euros/m2) and the increase of the lifetime (above 15 years) are the two main targets for achieving both cost and environmental efficiency. An electrochromic device, implemented in cooling dominated areas and operated with an optimum control strategy for the maximum expected lifetime (25 years), can reduce the building energy requirements by 52%. Furthermore, the total energy savings provided will be 33 times more than the energy required for its production while the emission of 615 kg CO2 equivalent per electrochromic glazing unit can be avoided.
NASA Astrophysics Data System (ADS)
Shevelev, L. N.
2017-12-01
Estimates were given of economical and energy efficiency of breakthrough energy-saving technologies, which increase competitive advantages and provide energy efficiency of production while reducing negative impact on the environment through reduction of emissions of harmful substances and greenhouse gases in the atmosphere. Among these technologies, preference is given to the following: pulverized coal fuel, blast-furnace gas recycling, gasification of non-coking coal in bubble-type gas-generators, iron-ore concentrate briquetting with steam coal with further use of ore-coal briquettes in electric furnace steel making. Implementation of these technologies at iron and steel works will significantly reduce the energy intensity of production through reduction of expensive coking coal consumption by means of their substitution by less expensive non-coking (steam) coal, and natural gas substitution by own secondary energy resource, which is the reducing gas. As the result, plants will get an opportunity to become self-sufficient in energy-resources and free themselves entirely from expensive purchased energy resources (natural gas, electric power, and partially coking coals), and cross over to low-carbon development.
White Nail Radio Transmitter: Billion Dollar Savings through Energy Efficiency
2011-05-10
increase efficiency and reduce overall energy consumption ashore by 50 percent CNO, Navy Energy Vision, P 10 White Nail Vision Your Cell Phone Cell...Estimated Total Number of transmitters 3,000,000 Estimated total power saved Watt 1,250,000,000 Cell Phone Transmitter Efficiency 1.25 Gigawatts saved...Greenhouse Gas Power 4 1 Energy Navy Use 7.3 Billion kWh White Nail Cell Phone Savings 11 Billion kWh One and a half times!!! Saves the output of four of
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coughlin, J.; Kandt, A.
This report focuses on financial options developed specifically for renewable energy and energy efficiency projects in three California public school districts. Solar energy systems installed on public schools have a number of benefits that include utility bill savings, reductions in greenhouse gas emissions (GHGs) and other toxic air contaminants, job creation, demonstrating environmental leadership, and creating learning opportunities for students. In the 2011 economic environment, the ability to generate general-fund savings as a result of reducing utility bills has become a primary motivator for school districts trying to cut costs. To achieve meaningful savings, the size of the photovoltaic (PV)more » systems installed (both individually on any one school and collectively across a district) becomes much more important; larger systems are required to have a material impact on savings. Larger PV systems require a significant financial commitment and financing therefore becomes a critical element in the transaction. In simple terms, school districts can use two primary types of ownership models to obtain solar installations and cost savings across a school district. The PV installations can be financed and owned directly by the districts themselves. Alternatively, there are financing structures whereby another entity, such as a solar developer or its investors, actually own and operate the PV systems on behalf of the school district. This is commonly referred to as the 'third-party ownership model.' Both methods have advantages and disadvantages that should be weighed carefully.« less
A Framework to Improve Energy Efficient Behaviour at Home through Activity and Context Monitoring
García, Óscar; Alonso, Ricardo S.; Corchado, Juan M.
2017-01-01
Real-time Localization Systems have been postulated as one of the most appropriated technologies for the development of applications that provide customized services. These systems provide us with the ability to locate and trace users and, among other features, they help identify behavioural patterns and habits. Moreover, the implementation of policies that will foster energy saving in homes is a complex task that involves the use of this type of systems. Although there are multiple proposals in this area, the implementation of frameworks that combine technologies and use Social Computing to influence user behaviour have not yet reached any significant savings in terms of energy. In this work, the CAFCLA framework (Context-Aware Framework for Collaborative Learning Applications) is used to develop a recommendation system for home users. The proposed system integrates a Real-Time Localization System and Wireless Sensor Networks, making it possible to develop applications that work under the umbrella of Social Computing. The implementation of an experimental use case aided efficient energy use, achieving savings of 17%. Moreover, the conducted case study pointed to the possibility of attaining good energy consumption habits in the long term. This can be done thanks to the system’s real time and historical localization, tracking and contextual data, based on which customized recommendations are generated. PMID:28758987
Basic Steps to Using the Energy Savings Plus Health Guidelines
he Energy Savings Plus Health Guide equips school districts to integrate indoor air quality protections into school energy efficiency retrofits and other building upgrade projects. This document describes steps to using the Energy Savings Plus Health guide
Saving Energy. Managing School Facilities, Guide 3.
ERIC Educational Resources Information Center
Department for Education and Employment, London (England). Architects and Building Branch.
This guide offers information on how schools can implement an energy saving action plan to reduce their energy costs. Various low-cost energy-saving measures are recommended covering heating levels and heating systems, electricity demand reduction and lighting, ventilation, hot water usage, and swimming pool energy management. Additional…
Reported Energy and Cost Savings from the DOE ESPC Program: FY 2015
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slattery, Bob S.
2017-01-01
The objective of this work was to determine the realization rate of energy and cost savings from the Department of Energy’s Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 151 Measurement and Verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year. Because the quality of the reports varied, it was not possible to determine all of these parameters for each project.
EPA ENERGY STAR: Tackling Growth in Home Electronics and Small Appliances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanchez, Marla Christine; Brown, Richard; Homan, Gregory
2008-11-17
Over a decade ago, the electricity consumption associated with home electronics and other small appliances emerged onto the global energy policy landscape as one of the fastest growing residential end uses with the opportunity to deliver significant energy savings. As our knowledge of this end use matures, it is essential to step back and evaluate the degree to which energy efficiency programs have successfully realized energy savings and where savings opportunities have been missed.For the past fifteen years, we have quantified energy, utility bill, and carbon savings for US EPA?s ENERGY STAR voluntary product labeling program. In this paper, wemore » present a unique look into the US residential program savings claimed to date for EPA?s ENERGY STAR office equipment, consumer electronics, and other small household appliances as well as EPA?s projected program savings over the next five years. We present a top-level discussion identifying program areas where EPA?s ENERGY STAR efforts have succeeded and program areas where ENERGY STAR efforts did not successfully address underlying market factors, technology issues and/or consumer behavior. We end by presenting the magnitude of ?overlooked? savings.« less
NREL and Army Validate Energy Savings for Net Zero Energy Installations |
News | NREL and Army Validate Energy Savings for Net Zero Energy Installations News Release : NREL and Army Validate Energy Savings for Net Zero Energy Installations October 27, 2014 The U.S. Army (Army) has partnered with the Energy Department's National Renewable Energy Laboratory (NREL) to
Ahorre Energia: Consejos sobre el ahorro de dinero y energia en el hogar (Book)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Learn how to save money with Energy Saver: Tips on Saving Money & Energy at Home, from the U.S. Department of Energy. The Energy Saver guide will help you reduce your monthly energy costs and live more efficiently. This guide takes you through the systems and appliances that consume the most energy in your home, and provides solutions to cut costs for you while saving the environment. The Energy Saver guide also includes transportation tips to help you save money at the pump.
Methods for assessing the energy-saving efficiency of industrial symbiosis in industrial parks.
Li, Wenfeng; Cui, Zhaojie; Han, Feng
2015-01-01
The available energy resources are being depleted worldwide. Industrial symbiosis (IS) provides a promising approach for increasing the efficiency of energy utilization, with numerous studies reporting the superiority of this technology. However, studies quantifying the energy-saving efficiency of IS remain insufficient. This paper proposes an index system for the quantitative evaluation of the energy-saving efficiency of IS. Both energy-saving and financial indexes were selected, the former include the IS energy-saving index, the contribution rate of energy saved through IS, fractional energy savings, and cut rate of energy consumption per total output value; and the latter include the IS investment payback period, IS input-output ratio, net present value (NPV), and internal rate of return (IRR) of IS. The proposed methods were applied to a case study on the XF Industrial Park (XF IP), in the city of Liaocheng in Shandong Province of China. Three energy-saving channels using IS were found in the XF IP: (a) utilizing the energy of high-temperature materials among industrial processes, (b) recovering waste heat and steam between different processes, and (c) saving energy by sharing infrastructures. The results showed that the energy efficiency index of IS was 0.326, accounting for 34.6% of the comprehensive energy-saving index in 2011, and the fractional energy-savings were 12.42%. The index of energy consumption per total industrial output value varied from 90.9 tce/MRMB to 51.6 tce/MRMB. Thus, the cut rate of energy consumption per total industrial output value was 43.42%. The average values of the IS input-output ratio was 406.2 RMB/tce, 57.2% lower than the price of standard coal. Static investment payback period in the XF IP was 8.5 months, indicating that the XF IP began to earn profit 8.5 months after the construction of all IS modes. The NVP and IRR of each IS mode in the XF IP were greater than zero, with average values equal to 1,789.96 MRMB and 140.96%, respectively. The computation result for each indicator revealed that IS could lead to the use of energy with high efficiency and lighten the financial burden of enterprises in the XF IP. And the proposed index system may help IPs and EIPs to make strategic decisions when designing IS modes.
ERIC Educational Resources Information Center
Harrigan, Merrilee
1999-01-01
The nonprofit Alliance to Save Energy has been helping schools reduce energy consumption through a combination of retrofits, classroom instruction, and behavior. Lists eight small steps to big energy savings, among them: involve the whole school, stop leaks, turn off computers, and recycle. (MLF)
Innovative Phase Change Approach for Significant Energy Savings
2016-09-01
September 2016 Innovative Phase Change Approach For Significant Energy Savings September 2016 8 After conducting a market survey...FINAL REPORT Innovative Phase Change Approach for Significant Energy Savings ESTCP Project EW-201138 SEPTEMBER 2016 Dr. Aly H Shaaban Applied...5a. CONTRACT NUMBER W912HQ-11-C-0011 Innovative Phase Change Approach for Significant Energy Savings 5b. GRANT NUMBER 5c. PROGRAM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Satchwell, Andrew; Cappers, Peter; Goldman, Charles
2011-03-22
Energy efficiency resource standards (EERS) are a prominent strategy to potentially achieve rapid and aggressive energy savings goals in the U.S. As of December 2010, twenty-six U.S. states had some form of an EERS with savings goals applicable to energy efficiency (EE) programs paid for by utility customers. The European Union has initiated a similar type of savings goal, the Energy End-use Efficiency and Energy Services Directive, where it is being implemented in some countries through direct partnership with regulated electric utilities. U.S. utilities face significant financial disincentives under traditional regulation which affects the interest of shareholders and managers inmore » aggressively pursuing cost-effective energy efficiency. Regulators are considering some combination of mandated goals ('sticks') and alternative utility business model components ('carrots' such as performance incentives) to align the utility's business and financial interests with state and federal energy efficiency public policy goals. European countries that have directed their utilities to administer EE programs have generally relied on non-binding mandates and targets; in the U.S., most state regulators have increasingly viewed 'carrots' as a necessary condition for successful achievement of energy efficiency goals and targets. In this paper, we analyze the financial impacts of an EERS on a large electric utility in the State of Arizona using a pro-forma utility financial model, including impacts on utility earnings, customer bills and rates. We demonstrate how a viable business model can be designed to improve the business case while retaining sizable ratepayer benefits. Quantifying these concerns and identifying ways they can be addressed are crucial steps in gaining the support of major stakeholder groups - lessons that can apply to other countries looking to significantly increase savings targets that can be achieved from their own utility-administered EE programs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cimpan, Ciprian, E-mail: cic@kbm.sdu.dk; Wenzel, Henrik
2013-07-15
Highlights: • Compared systems achieve primary energy savings between 34 and 140 MJ{sub primary}/100 MJ{sub input} {sub waste.} • Savings magnitude is foremost determined by chosen primary energy and materials production. • Energy consumption and process losses can be upset by increased technology efficiency. • Material recovery accounts for significant shares of primary energy savings. • Direct waste-to-energy is highly efficient if cogeneration (CHP) is possible. - Abstract: Primary energy savings potential is used to compare five residual municipal solid waste treatment systems, including configurations with mechanical (MT) and mechanical–biological (MBT) pre-treatment, which produce waste-derived fuels (RDF and SRF), biogasmore » and/or recover additional materials for recycling, alongside a system based on conventional mass burn waste-to-energy and ash treatment. To examine the magnitude of potential savings we consider two energy efficiency levels (state-of-the-art and best available technology), the inclusion/exclusion of heat recovery (CHP vs. PP) and three different background end-use energy production systems (coal condensing electricity and natural gas heat, Nordic electricity mix and natural gas heat, and coal CHP energy quality allocation). The systems achieved net primary energy savings in a range between 34 and 140 MJ{sub primary}/100 MJ{sub input} {sub waste}, in the different scenario settings. The energy footprint of transportation needs, pre-treatment and reprocessing of recyclable materials was 3–9.5%, 1–18% and 1–8% respectively, relative to total energy savings. Mass combustion WtE achieved the highest savings in scenarios with CHP production, nonetheless, MBT-based systems had similarly high performance if SRF streams were co-combusted with coal. When RDF and SRF was only used in dedicated WtE plants, MBT-based systems totalled lower savings due to inherent system losses and additional energy costs. In scenarios without heat recovery, the biodrying MBS-based system achieved the highest savings, on the condition of SRF co-combustion. As a sensitivity scenario, alternative utilisation of SRF in cement kilns was modelled. It supported similar or higher net savings for all pre-treatment systems compared to mass combustion WtE, except when WtE CHP was possible in the first two background energy scenarios. Recovery of plastics for recycling before energy recovery increased net energy savings in most scenario variations, over those of full stream combustion. Sensitivity to assumptions regarding virgin plastic substitution was tested and was found to mostly favour plastic recovery.« less
Schwartz, Daniel; Bruine de Bruin, Wändi; Fischhoff, Baruch; Lave, Lester
2015-06-01
Many consumers have monetary or environmental motivations for saving energy. Indeed, saving energy produces both monetary benefits, by reducing energy bills, and environmental benefits, by reducing carbon footprints. We examined how consumers' willingness and reasons to enroll in energy-savings programs are affected by whether advertisements emphasize monetary benefits, environmental benefits, or both. From a normative perspective, having 2 noteworthy kinds of benefit should not decrease a program's attractiveness. In contrast, psychological research suggests that adding external incentives to an intrinsically motivating task may backfire. To date, however, it remains unclear whether this is the case when both extrinsic and intrinsic motivations are inherent to the task, as with energy savings, and whether removing explicit mention of extrinsic motivation will reduce its importance. We found that emphasizing a program's monetary benefits reduced participants' willingness to enroll. In addition, participants' explanations about enrollment revealed less attention to environmental concerns when programs emphasized monetary savings, even when environmental savings were also emphasized. We found equal attention to monetary motivations in all conditions, revealing an asymmetric attention to monetary and environmental motives. These results also provide practical guidance regarding the positioning of energy-saving programs: emphasize intrinsic benefits; the extrinsic ones may speak for themselves. (c) 2015 APA, all rights reserved).
The environmental impacts of foamed concrete production and exploitation
NASA Astrophysics Data System (ADS)
Namsone, E.; Korjakins, A.; Sahmenko, G.; Sinka, M.
2017-10-01
This paper presents a study focusing on the environmental impacts of foamed concrete production and exploitation. CO2 emissions are very important factor for describing durability and sustainability of any building material and its life cycle. The building sector is one of the largest energy-consuming sectors in the world. In this study CO2 emissions are evaluated with regard to three types of energy resources (gas, coal and eco-friendly fuel). The related savings on raw materials are up to 120 t of water per 1000 t of traditionally mixed foamed concrete and up to 350 t of sand per 1000 t of foamed concrete produced with intensive mixing technology. In addition, total reduction of CO2 emissions (up to 60 t per 1000 m3 of material) and total energy saving from introduction of foamed concrete production (depending on the type of fuel) were calculated. In order to analyze the conditions of exploitation, both thermal conductivity and thickness of wall was determined. All obtained and calculated results were compared to those of the commercially produced autoclaved aerated concrete.
Energy performance and savings potentials with skylights
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arasteh, D.; Johnson, R.; Selkowitz, S.
1984-12-01
This study systematically explores the energy effects of skylight systems in a prototypical office building module and examines the savings from daylighting. For specific climates, roof/skylight characteristics are identified that minimize total energy or peak electrical demand. Simplified techniques for energy performance calculation are also presented based on a multiple regression analysis of our data base so that one may easily evaluate daylighting's effects on total and component energy loads and electrical peaks. This provides additional insights into the influence of skylight parameters on energy consumption and electrical peaks. We use the DOE-2.1B energy analysis program with newly incorporated daylightingmore » algorithms to determine hourly, monthly, and annual impacts of daylighting strategies on electrical lighting consumption, cooling, heating, fan power, peak electrical demands, and total energy use. A data base of more than 2000 parametric simulations for 14 US climates has been generated. Parameters varied include skylight-to-roof ratio, shading coefficient, visible transmittance, skylight well light loss, electric lighting power density, roof heat transfer coefficient, and electric lighting control type. 14 references, 13 figures, 4 tables.« less
Energy Efficiency Potential in the U.S. Single-Family Housing Stock
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, Eric J.; Christensen, Craig B.; Horowitz, Scott G.
Typical approaches for assessing energy efficiency potential in buildings use a limited number of prototypes, and therefore suffer from inadequate resolution when pass-fail cost-effectiveness tests are applied, which can significantly underestimate or overestimate the economic potential of energy efficiency technologies. This analysis applies a new approach to large-scale residential energy analysis, combining the use of large public and private data sources, statistical sampling, detailed building simulations, and high-performance computing to achieve unprecedented granularity - and therefore accuracy - in modeling the diversity of the single-family housing stock. The result is a comprehensive set of maps, tables, and figures showing themore » technical and economic potential of 50 plus residential energy efficiency upgrades and packages for each state. Policymakers, program designers, and manufacturers can use these results to identify upgrades with the highest potential for cost-effective savings in a particular state or region, as well as help identify customer segments for targeted marketing and deployment. The primary finding of this analysis is that there is significant technical and economic potential to save electricity and on-site fuel use in the single-family housing stock. However, the economic potential is very sensitive to the cost-effectiveness criteria used for analysis. Additionally, the savings of particular energy efficiency upgrades is situation-specific within the housing stock (depending on climate, building vintage, heating fuel type, building physical characteristics, etc.).« less
Design and Implementation of Green Construction Scheme for a High-rise Residential Building Project
NASA Astrophysics Data System (ADS)
Zhou, Yong; Huang, You Zhen
2018-06-01
This paper mainly studies the green construction scheme of a high-rise residential building project. From "four sections one environmental protection", saving material, water saving, energy saving, economical use of land and environmental protection conduct analysis and research. Adopting scientific, advanced, reasonable and economical construction technology measures, implementing green construction method. Promoting energy-saving technologies in buildings, ensuring the sustainable use of resources, Maximum savings of resources and energy, increase energy efficiency, to reduce pollution, reducing the adverse environmental impact of construction activities, ensure construction safety, build sustainable buildings.
Policy options for the split incentive: Increasing energy efficiency for low-income renters.
Bird, Stephen; Hernández, Diana
2012-09-01
The split incentive problem concerns the lack of appropriate incentives to implement energy efficiency measures. In particular, low income tenants face a phenomenon of energy poverty in which they allocate significantly more of their household income to energy expenditures than other renters. This problem is substantial, affecting 1.89% of all United States' energy use. If effectively addressed, it would create a range of savings between 4 and 11 billion dollars per year for many of the nation's poorest residents. We argue that a carefully designed program of incentives for participants (including landlords) in conjunction with a unique type of utility-managed on-bill financing mechanism has significant potential to solve many of the complications. We focus on three kinds of split incentives, five concerns inherent to addressing split incentive problems (scale, endurance, incentives, savings, political disfavor), and provide a detailed policy proposal designed to surpass those problems, with a particular focus on low-income tenants in a U.S.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-01-01
This environmental assessment (EA) evaluates the environmental impacts resulting from new or amended energy-efficiency standards for dishwashers, clothes washers and clothes dryers as mandated by the National Appliance Energy Conservation Act of 1987. A complete description of the Engineering and Economic Analysis of the proposed standards may be found elsewhere in the Technical Support Document (TSD). All eleven of the scenarios for product design changes described in the Engineering Analysis of the TSD are analyzed in the environmental assessment in the form of levels of pollutant reduction. Level 1 represents the least amount of pollutant reduction, while higher numbered levelsmore » represent increasingly more stringent standards, with correspondingly greater reductions in pollutants. Values for energy savings that result from product design changes are taken from the TSD. These energy savings are based on recent data on actual usage rather than DOE test procedures. 12 refs., 1 fig., 12 tabs.« less
Policy options for the split incentive: Increasing energy efficiency for low-income renters
Bird, Stephen; Hernández, Diana
2016-01-01
The split incentive problem concerns the lack of appropriate incentives to implement energy efficiency measures. In particular, low income tenants face a phenomenon of energy poverty in which they allocate significantly more of their household income to energy expenditures than other renters. This problem is substantial, affecting 1.89% of all United States' energy use. If effectively addressed, it would create a range of savings between 4 and 11 billion dollars per year for many of the nation's poorest residents. We argue that a carefully designed program of incentives for participants (including landlords) in conjunction with a unique type of utility-managed on-bill financing mechanism has significant potential to solve many of the complications. We focus on three kinds of split incentives, five concerns inherent to addressing split incentive problems (scale, endurance, incentives, savings, political disfavor), and provide a detailed policy proposal designed to surpass those problems, with a particular focus on low-income tenants in a U.S. context. PMID:27053828
The Energy Savings Plus Health Guide equips school districts to integrate indoor air quality protections into school energy efficiency retrofits and other building upgrade projects. This page describes the business case for energy savings in schools.
A Novel Sensor Platform Matching the Improved Version of IPMVP Option C for Measuring Energy Savings
Tseng, Yen-Chieh; Lee, Da-Sheng; Lin, Cheng-Fang; Chang, Ching-Yuan
2013-01-01
It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP) was proposed by the Efficiency Valuation Organization (EVO) to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information) and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC) global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS). A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V) processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the carbon footprint of a building. PMID:23698273
NASA Technical Reports Server (NTRS)
1979-01-01
One of the most comprehensive and most effective programs is NECAP, an acronym for NASA Energy Cost Analysis Program. Developed by Langley Research Center, NECAP operates according to heating/cooling calculation procedures formulated by the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE). The program enables examination of a multitude of influences on heat flow into and out of buildings. For example, NECAP considers traditional weather patterns for a given locale and predicts the effects on a particular building design of sun, rain, wind, even shadows from other buildings. It takes into account the mass of structural materials, insulating values, the type of equipment the building will house, equipment operating schedules, heat by people and machinery, heat loss or gain through windows and other openings and a variety of additional details. NECAP ascertains how much energy the building should require ideally, aids selection of the most economical and most efficient energy systems and suggests design and operational measures for reducing the building's energy needs. Most importantly, NECAP determines cost effectiveness- whether an energy-saving measure will pay back its installation cost through monetary savings in energy bills. thrown off
Behaviour: The net effect of green lifestyles
NASA Astrophysics Data System (ADS)
Hubacek, Klaus; Guan, Dabo
2011-08-01
It is often argued that saving energy helps the environment and saves money. An analysis of three energy-saving measures shows that decisions on how the saved money is spent affect the size of the environmental benefit.
Energy Control Systems: Energy Savings.
ERIC Educational Resources Information Center
School Business Affairs, 1980
1980-01-01
The installation of proper control systems is estimated as saving up to 25 percent of the energy used in schools. Other potential energy-saving areas are transmission (heat loss or gain through walls, especially ceilings); internal load (heat from students, lights, and machinery); ventilation; and equipment maintenance. (Author/MLF)
NASA Astrophysics Data System (ADS)
Vasilev, V. Ya; Nikiforova, S. A.
2018-03-01
Experimental studies of thermo-aerodynamic characteristics of non-circular ducts with discrete turbulators on walls and interrupted channels have confirmed the rational enhancement of convective heat transfer, in which the growth of heat transfer outstrips or equals the growth of aerodynamic losses. Determining the regularities of rational (energy-saving) enhancement of heat transfer and the proposed method for comparing the characteristics of smooth-channel (without enhancement) heat exchangers with effective analogs provide new results, confirming the high efficiency of vortex enhancement of convective heat transfer in non-circular ducts of plate-finned heat exchange surfaces. This allows creating heat exchangers with much smaller mass and volume for operation in energy-saving modes.
HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant
2016-09-01
material was applied. Annual energy and cost savings were predicted based on a typical weather year for each site. The installation of the duct...Balance reports; Visible dust streaks on duct work, ceilings near supply diffusers, or electrical boxes; Comfort complaints Specific Leakage...energy consumption , depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is
ERIC Educational Resources Information Center
California Univ., Berkeley. Lawrence Berkeley Lab.
Presented are ways in which consumers can improve the energy efficiency of their homes and conserve water. Organized by types of energy use, the guide points out what to look for and what changes to consider as homeowners inspect heating and air conditioning systems, the hot water system, kitchen appliances, lighting, and water use. Conservation…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyers, Stephen; Williams, Alison; Chan, Peter
This paper presents estimates of the key impacts of the energy and water conservation standards that have been adopted from 1987 through 2010. The standards covered include those set by legislation as well as standards adopted by DOE through rulemaking. We estimate that energy efficiency standards for consumer products and certain commercial and industrial equipment that have been adopted from 1987 through 2010 saved 3.0 quads in 2010, have had a cumulative energy savings of 25.9 quads through 2010 and will achieve cumulative energy savings of 158 quads over the period 1990-2070. Thus, the majority of the savings are stillmore » to come as products subject to standards enter the stock. Furthermore, the standards will have a cumulative net present value (NPV) of consumer benefit of between $851 billion and $1,103 billion, using 7 percent and 3 percent discount rates, respectively. In addition, we estimate the water conservation standards, together with those energy conservation standards that also save water, saved residential consumers 1.5 trillion gallons of water in 2010, have had cumulative water savings of 11.7 trillion gallons through 2010, and will achieve cumulative water savings by 2040 of 51.4 trillion gallons.« less
ERIC Educational Resources Information Center
Aktamis, Hilal
2011-01-01
The aim of this study was to determine energy saving behavior and energy awareness of secondary school students and the effects of socio-demographic characteristics (gender, residential area and grade level) on energy saving and energy awareness. The research is a survey model with an approach that aims to describe the current status. A total of…
Supermarket refrigeration assessment for the Commonwealth Electric Company
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsaros, T.L.; Walker, D.H.
The Commonwealth Electric Company (COM/Electric) has initiated an incentive program to promote electric energy conservation within its service territory. The Electric Power Research Institute (EPRI) has assisted COM/Electric in assessing the impact on the utility and its customers of implementing energy efficient supermarket refrigeration in retrofit applications. The primary task of this assessment was to contact the supermarket chains and refrigeration contractors and suppliers in the COM/Electric service territory to determine the type of refrigeration employed and standard or novel retrofit equipment implemented in supermarkets. With this information, estimates were made of the potential energy savings that COM/Electric and themore » supermarkets could realize if supermarkets were retrofitted with energy efficient refrigeration equipment. It was determined that the refrigerated display case features offering the greatest potential for savings through retrofit installations include doors for medium temperature multideck cases, high-efficiency fan motors, anti-sweat heater controls, and vinyl strip curtains for walk-in coolers. The retrofit components associated with the compressor machine room that offer the greatest potential for savings include the use of low heat pressure control, hot gas defrost, and external liquid-suction heat exchangers and remote evaporative subcoolers for low temperature refrigeration. 6 refs., 14 figs., 26 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tonn, Bruce Edward; Carroll, David; Pigg, Scott
This report presents a summary of the studies and analyses that compose the retrospective evaluation of the U.S. Department of Energy s low-income Weatherization Assistance Program (WAP). WAP provides grants to Grantees (i.e., states) that then provide grants to Subgrantees (i.e., local weatherization agencies) to weatherize low-income homes. This evaluation focused on the WAP Program Year 2008. The retrospective evaluation produced twenty separate reports, including this summary. Four separate reports address the energy savings, energy cost savings, and cost effectiveness of WAP across four housing types: single family, mobile home, small multifamily, and large multifamily. Other reports address the environmentalmore » emissions, macroeconomic, and health and household-related benefits attributable to WAP, and characterize the program, its recipients, and those eligible for the program. Major field studies are also summarized, including a major indoor air quality study and a follow-up ventilation study, an in-depth in-field assessment of weatherization work and quality, and a study that assesses reasons for variations in energy savings across homes. Results of surveys of weatherization staff, occupants, occupants satisfaction with weatherization services provided, and weatherization trainees are summarized. Lastly, this report summarizes a set of fifteen case studies of high-performing and unique local weatherization agencies.« less
NASA Astrophysics Data System (ADS)
Arida, Maya Ahmad
In 1972 sustainable development concept existed and during The years it became one of the most important solution to save natural resources and energy, but now with rising energy costs and increasing awareness of the effect of global warming, the development of building energy saving methods and models become apparently more necessary for sustainable future. According to U.S. Energy Information Administration EIA (EIA), today buildings in the U.S. consume 72 percent of electricity produced, and use 55 percent of U.S. natural gas. Buildings account for about 40 percent of the energy consumed in the United States, more than industry and transportation. Of this energy, heating and cooling systems use about 55 percent. If energy-use trends continue, buildings will become the largest consumer of global energy by 2025. This thesis proposes procedures and analysis techniques for building energy system and optimization methods using time series auto regression artificial neural networks. The model predicts whole building energy consumptions as a function of four input variables, dry bulb and wet bulb outdoor air temperatures, hour of day and type of day. The proposed model and the optimization process are tested using data collected from an existing building located in Greensboro, NC. The testing results show that the model can capture very well the system performance, and The optimization method was also developed to automate the process of finding the best model structure that can produce the best accurate prediction against the actual data. The results show that the developed model can provide results sufficiently accurate for its use in various energy efficiency and saving estimation applications.
76 FR 56408 - Notice of Proposed Information Collection Requests
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-13
... Communications and Outreach Type of Review: NEW. Title of Collection: Green Ribbon Schools Application Package. OMB Control Number: Pending. Agency Form Number(s): N/A. Frequency of Responses: Annually. Affected... private elementary, middle and high schools that save energy, reduce costs, protect health, foster...
Save Energy Now Assessments Results 2008 Summary Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, Anthony L; Martin, Michaela A; Nimbalkar, Sachin U
In October 2005, U.S. Department of Energy Secretary Bodman launched his Easy Ways to Save Energy campaign with a promise to provide energy assessments to 200 of the largest U.S. manufacturing plants. DOE's Industrial Technologies Program (ITP) responded to the Secretary's campaign with its Save Energy Now initiative, featuring a new and highly cost-effective form of energy savings assessment. The approach for these assessments drew heavily on the existing resources of ITP's technology delivery component. Over the years, ITP Technology Delivery has worked with industry partners to assemble a suite of respected software tools, proven assessment protocols, training curricula, certified energy experts, and strong partnerships for deployment. The Save Energy Now assessments conducted in calendar year 2006 focused on natural gas savings and targeted many of the nation's largest manufacturing plants - those that consume at least 1 TBtu of energy annually. The 2006 Save Energy Now assessments focused primarily on assessments of steam and process heating systems, which account for an estimated 74% of all natural gas use by U.S. manufacturing plants. Because of the success of the Save Energy Now assessments conducted in 2006 and 2007, the program was expanded and enhanced in two major ways in 2008: (1) a new goal was set to perform at least 260 assessments; and (2) the assessment focus was expanded to include pumping, compressed air, and fan systems in addition to steam and process heating. DOE ITP also has developed software tools to assess energy efficiency improvement opportunities in pumping, compressed air, and fan systems. The Save Energy Now assessments integrate a strong training component designed to teach industrial plant personnel how to use DOE's opportunity assessment software tools. This approach has the advantages of promoting strong buy-in of plant personnel for the assessment and its outcomes and preparing them better to independently replicate the assessment process at the company's other facilities. Another important element of the Save Energy Now assessment process is the follow-up process used to identify how many of the recommended savings opportunities from individual assessments have been implemented in the industrial plants. Plant personnel involved with the Save Energy Now assessments are contacted 6 months, 12 months, and 24 months after individual assessments are completed to determine implementation results. A total of 260 Save Energy Now assessments were successfully completed in calendar year 2008. This means that a total of 718 assessments were completed in 2006, 2007, and 2008. As of July 2009, we have received a total of 239 summary reports from the ESAs that were conducted in year 2008. Hence, at the time that this report was prepared, 680 final assessment reports were completed (200 from year 2006, 241 from year 2007, and 239 from year 2008). The total identified potential cost savings from these 680 assessments ismore » $$1.1 billion per year, including natural gas savings of about 98 TBtu per year. These results, if fully implemented, could reduce CO{sub 2} emissions by about 8.9 million metric tons annually. When this report was prepared, data on implementation of recommended energy and cost savings measures from 488 Save Energy Now assessments were available. For these 488 plants, measures saving a total of $$147 million per year have been implemented, measures that will save $169 million per year are in the process of being implemented, and plants are planning implementation of measures that will save another $239 million per year. The implemented recommendations are already achieving total CO{sub 2} reductions of about 1.8 million metric tons per year. This report provides a summary of the key results for the Save Energy Now assessments completed in 2008; details of the 6-month, 12-month, and 24-month implementation results obtained to date; and an evaluation of these implementation results. This report also summarizes key accomplishments, findings, and lessons learned from all the Save Energy Now assessments completed to date. A separate report (Wright et al. 2010) provides more detailed information on key results for all of the 2008 assessments of steam, process heating, pumping, compressed air, and fan systems. Two prior reports (Wright et al. 2007 and Wright et al. 2009) detail the results from the 2006 and 2007 assessments and discuss the major components of the assessment process and improvements in the process made in 2007.« less
Save Energy Now Assessments Results 2008 Detailed Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, Anthony L; Martin, Michaela A; Nimbalkar, Sachin U
In October 2005, U.S. Department of Energy Secretary Bodman launched his Easy Ways to Save Energy campaign with a promise to provide energy assessments to 200 of the largest U.S. manufacturing plants. DOE's Industrial Technologies Program (ITP) responded to the Secretary's campaign with its Save Energy Now initiative, featuring a new and highly cost-effective form of energy savings assessment. The approach for these assessments drew heavily on the existing resources of ITP's technology delivery component. Over the years, ITP Technology Delivery has worked with industry partners to assemble a suite of respected software tools, proven assessment protocols, training curricula, certified energy experts, and strong partnerships for deployment. The Save Energy Now assessments conducted in calendar year 2006 focused on natural gas savings and targeted many of the nation's largest manufacturing plants - those that consume at least 1 TBtu of energy annually. The 2006 Save Energy Now assessments focused primarily on assessments of steam and process heating systems, which account for an estimated 74% of all natural gas use by U.S. manufacturing plants. Because of the success of the Save Energy Now assessments conducted in 2006 and 2007, the program was expanded and enhanced in two major ways in 2008: (1) a new goal was set to perform at least 260 assessments; and (2) the assessment focus was expanded to include pumping, compressed air, and fan systems in addition to steam and process heating. DOE ITP also has developed software tools to assess energy efficiency improvement opportunities in pumping, compressed air, and fan systems. The Save Energy Now assessments integrate a strong training component designed to teach industrial plant personnel how to use DOE's opportunity assessment software tools. This approach has the advantages of promoting strong buy-in of plant personnel for the assessment and its outcomes and preparing them better to independently replicate the assessment process at the company's other facilities. Another important element of the Save Energy Now assessment process is the follow-up process used to identify how many of the recommended savings opportunities from individual assessments have been implemented in the industrial plants. Plant personnel involved with the Save Energy Now assessments are contacted 6 months, 12 months, and 24 months after individual assessments are completed to determine implementation results. A total of 260 Save Energy Now assessments were successfully completed in calendar year 2008. This means that a total of 718 assessments were completed in 2006, 2007, and 2008. As of July 2009, we have received a total of 239 summary reports from the ESAs that were conducted in year 2008. Hence, at the time that this report was prepared, 680 final assessment reports were completed (200 from year 2006, 241 from year 2007, and 239 from year 2008). The total identified potential cost savings from these 680 assessments ismore » $$1.1 billion per year, including natural gas savings of about 98 TBtu per year. These results, if fully implemented, could reduce CO{sub 2} emissions by about 8.9 million metric tons annually. When this report was prepared, data on implementation of recommended energy and cost savings measures from 488 Save Energy Now assessments were available. For these 488 plants, measures saving a total of $$147 million per year have been implemented, measures that will save $169 million per year are in the process of being implemented, and plants are planning implementation of measures that will save another $239 million per year. The implemented recommendations are already achieving total CO{sub 2} reductions of about 1.8 million metric tons per year. This report provides a summary of the key results for the Save Energy Now assessments completed in 2008; details of the 6-month, 12-month, and 24-month implementation results obtained to date; and an evaluation of these implementation results. This report also summarizes key accomplishments, findings, and lessons learned from all the Save Energy Now assessments completed to date. A separate report (Wright et al. 2010) provides more detailed information on key results for all of the 2008 assessments of steam, process heating, pumping, compressed air, and fan systems. Two prior reports (Wright et al. 2007 and Wright et al. 2009) detail the results from the 2006 and 2007 assessments and discuss the major components of the assessment process and improvements in the process made in 2007.« less
Public perceptions of energy consumption and savings
Attari, Shahzeen Z.; DeKay, Michael L.; Davidson, Cliff I.; Bruine de Bruin, Wändi
2010-01-01
In a national online survey, 505 participants reported their perceptions of energy consumption and savings for a variety of household, transportation, and recycling activities. When asked for the most effective strategy they could implement to conserve energy, most participants mentioned curtailment (e.g., turning off lights, driving less) rather than efficiency improvements (e.g., installing more efficient light bulbs and appliances), in contrast to experts’ recommendations. For a sample of 15 activities, participants underestimated energy use and savings by a factor of 2.8 on average, with small overestimates for low-energy activities and large underestimates for high-energy activities. Additional estimation and ranking tasks also yielded relatively flat functions for perceived energy use and savings. Across several tasks, participants with higher numeracy scores and stronger proenvironmental attitudes had more accurate perceptions. The serious deficiencies highlighted by these results suggest that well-designed efforts to improve the public's understanding of energy use and savings could pay large dividends. PMID:20713724
Existing Whole-House Solutions Case Study: Cascade Apartments - Deep Energy Multifamily Retrofit
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-02-01
In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington, which resulted in annual energy cost savings of 22%, improved comfort and air quality for residents, and increased durability of the units. This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary Building America research questions: 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings comparemore » with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio of the retrofit package after considering utility window incentives and KCHA capital improvement funding.« less
Energy conservation through sealing technology
NASA Technical Reports Server (NTRS)
Stair, W. K.; Ludwig, L. P.
1978-01-01
Improvements in fluid film sealing resulting from a proposed research program could lead to an annual energy saving, on a national basis, equivalent to about 37 million bbl of oil or 0.3% of the total U.S. energy consumption. Further, the application of known sealing technology can result in an annual saving of an additional 10 million bbl of oil. The energy saving would be accomplished by reduction in process heat energy loss, reduction of frictional energy generated, and minimization of energy required to operate ancillary equipment associated with the seal system. In addition to energy saving, cost effectiveness is further enhanced by reduction in maintenance and in minimization of equipment for collecting leakage and for meeting environmental pollution standards.
Center for the Built Environment: Setpoint Energy Savings Calculator
. Arens, and H. Zhang, 2014. Extending air temperature setpoints: Simulated energy savings and design Near-ZNE Buildings Setpoint Energy Savings Calculator UFAD Case Studies UFAD Cooling Design Tool UFAD Cost Analysis UFAD Design Guide UFAD East End UFAD Energy Modeling UFAD Plenum Performance UFAD
Municipal Complex Solar Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sher, Jono; Toth, Andrew
2015-02-12
This project is a great benefit to the City of Perth Amboy by saving energy and savings costs. The project serves as a great example to city residents about the importance of renewable energy, energy conservation and other environmental topics. An electronic display in the City Hall shows how much energy was generated on that day, how much energy is saved, and environmental benefits. The project serves to educate people of environmental concerns and may spark the interest of individuals in other environmental topics. Hopefully, other residents will be encouraged to use solar energy. The project is also saving moneymore » for the City and its taxpayers. Anywhere we can save money means that residents can pay less in taxes and/or the City can provide improved services.« less
[Measures to reduce lighting-related energy use and costs at hospital nursing stations].
Su, Chiu-Ching; Chen, Chen-Hui; Chen, Shu-Hwa; Ping, Tsui-Chu
2011-06-01
Hospitals have long been expected to deliver medical services in an environment that is comfortable and bright. This expectation keeps hospital energy demand stubbornly high and energy costs spiraling due to escalating utility fees. Hospitals must identify appropriate strategies to control electricity usage in order to control operating costs effectively. This paper proposes several electricity saving measures that both support government policies aimed at reducing global warming and help reduce energy consumption at the authors' hospital. The authors held educational seminars, established a website teaching energy saving methods, maximized facility and equipment use effectiveness (e.g., adjusting lamp placements, power switch and computer saving modes), posted signs promoting electricity saving, and established a regularized energy saving review mechanism. After implementation, average nursing staff energy saving knowledge had risen from 71.8% to 100% and total nursing station electricity costs fell from NT$16,456 to NT$10,208 per month, representing an effective monthly savings of 37.9% (NT$6,248). This project demonstrated the ability of a program designed to slightly modify nursing staff behavior to achieve effective and meaningful results in reducing overall electricity use.
Voltage-dependent K+ channels improve the energy efficiency of signalling in blowfly photoreceptors
2017-01-01
Voltage-dependent conductances in many spiking neurons are tuned to reduce action potential energy consumption, so improving the energy efficiency of spike coding. However, the contribution of voltage-dependent conductances to the energy efficiency of analogue coding, by graded potentials in dendrites and non-spiking neurons, remains unclear. We investigate the contribution of voltage-dependent conductances to the energy efficiency of analogue coding by modelling blowfly R1-6 photoreceptor membrane. Two voltage-dependent delayed rectifier K+ conductances (DRs) shape the membrane's voltage response and contribute to light adaptation. They make two types of energy saving. By reducing membrane resistance upon depolarization they convert the cheap, low bandwidth membrane needed in dim light to the expensive high bandwidth membrane needed in bright light. This investment of energy in bandwidth according to functional requirements can halve daily energy consumption. Second, DRs produce negative feedback that reduces membrane impedance and increases bandwidth. This negative feedback allows an active membrane with DRs to consume at least 30% less energy than a passive membrane with the same capacitance and bandwidth. Voltage-dependent conductances in other non-spiking neurons, and in dendrites, might be organized to make similar savings. PMID:28381642
Voltage-dependent K+ channels improve the energy efficiency of signalling in blowfly photoreceptors.
Heras, Francisco J H; Anderson, John; Laughlin, Simon B; Niven, Jeremy E
2017-04-01
Voltage-dependent conductances in many spiking neurons are tuned to reduce action potential energy consumption, so improving the energy efficiency of spike coding. However, the contribution of voltage-dependent conductances to the energy efficiency of analogue coding, by graded potentials in dendrites and non-spiking neurons, remains unclear. We investigate the contribution of voltage-dependent conductances to the energy efficiency of analogue coding by modelling blowfly R1-6 photoreceptor membrane. Two voltage-dependent delayed rectifier K + conductances (DRs) shape the membrane's voltage response and contribute to light adaptation. They make two types of energy saving. By reducing membrane resistance upon depolarization they convert the cheap, low bandwidth membrane needed in dim light to the expensive high bandwidth membrane needed in bright light. This investment of energy in bandwidth according to functional requirements can halve daily energy consumption. Second, DRs produce negative feedback that reduces membrane impedance and increases bandwidth. This negative feedback allows an active membrane with DRs to consume at least 30% less energy than a passive membrane with the same capacitance and bandwidth. Voltage-dependent conductances in other non-spiking neurons, and in dendrites, might be organized to make similar savings. © 2017 The Author(s).
Data in support of energy performance of double-glazed windows.
Shakouri, Mahmoud; Banihashemi, Saeed
2016-06-01
This paper provides the data used in a research project to propose a new simplified windows rating system based on saved annual energy ("Developing an empirical predictive energy-rating model for windows by using Artificial Neural Network" (Shakouri Hassanabadi and Banihashemi Namini, 2012) [1], "Climatic, parametric and non-parametric analysis of energy performance of double-glazed windows in different climates" (Banihashemi et al., 2015) [2]). A full factorial simulation study was conducted to evaluate the performance of 26 different types of windows in a four-story residential building. In order to generalize the results, the selected windows were tested in four climates of cold, tropical, temperate, and hot and arid; and four different main orientations of North, West, South and East. The accompanied datasets include the annual saved cooling and heating energy in different climates and orientations by using the selected windows. Moreover, a complete dataset is provided that includes the specifications of 26 windows, climate data, month, and orientation of the window. This dataset can be used to make predictive models for energy efficiency assessment of double glazed windows.
Impact of Extended Daylight Saving Time on National Energy Consumption Report to Congress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belzer, D. B.; Hadley, S. W.; Chin, S-M.
2008-10-01
The Energy Policy Act of 2005 (Pub. L. No. 109-58; EPAct 2005) amended the Uniform Time Act of 1966 (Pub. L. No. 89-387) to increase the portion of the year that is subject to Daylight Saving Time. (15 U.S.C. 260a note) EPAct 2005 extended the duration of Daylight Saving Time in the spring by changing its start date from the first Sunday in April to the second Sunday in March, and in the fall by changing its end date from the last Sunday in October to the first Sunday in November. (15 U.S.C. 260a note) EPAct 2005 also called formore » the Department of Energy to evaluate the impact of Extended Daylight Saving Time on energy consumption in the United States and to submit a report to Congress. (15 U.S.C. 260a note) This report presents the results of impacts of Extended Daylight Saving Time on the national energy consumption in the United States. The key findings are: (1) The total electricity savings of Extended Daylight Saving Time were about 1.3 Tera Watt-hour (TWh). This corresponds to 0.5 percent per each day of Extended Daylight Saving Time, or 0.03 percent of electricity consumption over the year. In reference, the total 2007 electricity consumption in the United States was 3,900 TWh. (2) In terms of national primary energy consumption, the electricity savings translate to a reduction of 17 Trillion Btu (TBtu) over the spring and fall Extended Daylight Saving Time periods, or roughly 0.02 percent of total U.S. energy consumption during 2007 of 101,000 TBtu. (3) During Extended Daylight Saving Time, electricity savings generally occurred over a three- to five-hour period in the evening with small increases in usage during the early-morning hours. On a daily percentage basis, electricity savings were slightly greater during the March (spring) extension of Extended Daylight Saving Time than the November (fall) extension. On a regional basis, some southern portions of the United States exhibited slightly smaller impacts of Extended Daylight Saving Time on energy savings compared to the northern regions, a result possibly due to a small, offsetting increase in household air conditioning usage. (4) Changes in national traffic volume and motor gasoline consumption for passenger vehicles in 2007 were determined to be statistically insignificant and therefore, could not be attributed to Extended Daylight Saving Time.« less
DSM Electricity Savings Potential in the Buildings Sector in APP Countries
DOE Office of Scientific and Technical Information (OSTI.GOV)
McNeil, MIchael; Letschert, Virginie; Shen, Bo
2011-01-12
The global economy has grown rapidly over the past decade with a commensurate growth in the demand for electricity services that has increased a country's vulnerability to energy supply disruptions. Increasing need of reliable and affordable electricity supply is a challenge which is before every Asia Pacific Partnership (APP) country. Collaboration between APP members has been extremely fruitful in identifying potential efficiency upgrades and implementing clean technology in the supply side of the power sector as well established the beginnings of collaboration. However, significantly more effort needs to be focused on demand side potential in each country. Demand side managementmore » or DSM in this case is a policy measure that promotes energy efficiency as an alternative to increasing electricity supply. It uses financial or other incentives to slow demand growth on condition that the incremental cost needed is less than the cost of increasing supply. Such DSM measures provide an alternative to building power supply capacity The type of financial incentives comprise of rebates (subsidies), tax exemptions, reduced interest loans, etc. Other approaches include the utilization of a cap and trade scheme to foster energy efficiency projects by creating a market where savings are valued. Under this scheme, greenhouse gas (GHG) emissions associated with the production of electricity are capped and electricity retailers are required to meet the target partially or entirely through energy efficiency activities. Implementation of DSM projects is very much in the early stages in several of the APP countries or localized to a regional part of the country. The purpose of this project is to review the different types of DSM programs experienced by APP countries and to estimate the overall future potential for cost-effective demand-side efficiency improvements in buildings sectors in the 7 APP countries through the year 2030. Overall, the savings potential is estimated to be 1.7 thousand TWh or 21percent of the 2030 projected base case electricity demand. Electricity savings potential ranges from a high of 38percent in India to a low of 9percent in Korea for the two sectors. Lighting, fans, and TV sets and lighting and refrigeration are the largest contributors to residential and commercial electricity savings respectively. This work presents a first estimates of the savings potential of DSM programs in APP countries. While the resulting estimates are based on detailed end-use data, it is worth keeping in mind that more work is needed to overcome limitation in data at this time of the project.« less
Commercial GSHPs: Benefits Belie Lack of Popularity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cooperman, Alissa; Dieckmann, John; Brodrick, James
2012-05-31
This article discusses ground source heat pumps (GSHPs) for commercial building application as an alternative to conventional HVAC systems. A technology overview is presented as there are several types of GSHP and each has features making them better suited for certain building and lot types in addition to location climate. The article concludes with potential energy and cost savings offered by GSHPs and a brief market overview.
Aerodynamic Drag and Drag Reduction: Energy and Energy Savings (Invited)
NASA Technical Reports Server (NTRS)
Wood, Richard M.
2003-01-01
An assessment of the role of fluid dynamic resistance and/or aerodynamic drag and the relationship to energy use in the United States is presented. Existing data indicates that up to 25% of the total energy consumed in the United States is used to overcome aerodynamic drag, 27% of the total energy used in the United States is consumed by transportation systems, and 60% of the transportation energy or 16% of the total energy consumed in the United States is used to overcome aerodynamic drag in transportation systems. Drag reduction goals of 50% are proposed and discussed which if realized would produce a 7.85% total energy savings. This energy savings correlates to a yearly cost savings in the $30Billion dollar range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Wei; Gowri, Krishnan; Thornton, Brian A.
2010-06-30
This paper presents the process, methodology, and assumptions for development of the 50% Energy Savings Design Technology Packages for Highway Lodging Buildings, a design guidance document that provides specific recommendations for achieving 50% energy savings in roadside motels (highway lodging) above the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004. This 50% solution represents a further step toward realization of the U.S. Department of Energy’s net-zero energy building goal, and go beyond the 30% savings in the Advanced Energy Design Guide series (upon which this work was built). This work can serve as the technical feasibility study for the development of a 50%more » saving Advanced Energy Design Guide for highway lodging, and thus should greatly expedite the development process. The purpose of this design package is to provide user-friendly design assistance to designers, developers, and owners of highway lodging properties. It is intended to encourage energy-efficient design by providing prescriptive energy-efficiency recommendations for each climate zone that attains the 50% the energy savings target. This paper describes the steps that were taken to demonstrate the technical feasibility of achieving a 50% reduction in whole-building energy use with practical and commercially available technologies. The energy analysis results are presented, indicating the recommended energy-efficient measures achieved a national-weighted average energy savings of 55%, relative to Standard 90.1-2004. The cost-effectiveness of the recommended technology package is evaluated and the result shows an average simple payback of 11.3 years.« less
Quantifying the benefits of a building retrofit using an integrated system approach: A case study
Regnier, Cynthia; Sun, Kaiyu; Hong, Tianzhen; ...
2017-11-11
Building retrofits provide a large opportunity to significantly reduce energy consumption in the buildings sector. Traditional building retrofits focus on equipment upgrades, often at the end of equipment life or failure, and result in replacement with marginally improved similar technology and limited energy savings. The Integrated System (IS) retrofit approach enables much greater energy savings by leveraging interactive effects between end use systems, enabling downsized or lower energy technologies. This work presents a case study in Hawaii quantifying the benefits of an IS retrofit approach compared to two traditional retrofit approaches: a Standard Practice of upgrading equipment to meet minimummore » code requirements, and an Improved Practice of upgrading equipment to a higher efficiency. The IS approach showed an energy savings of 84% over existing building energy use, much higher than the traditional approaches of 13% and 33%. The IS retrofit also demonstrated the greatest energy cost savings potential. While the degree of savings realized from the IS approach will vary by building and climate, these findings indicate that savings on the order of 50% and greater are not possible without an IS approach. It is therefore recommended that the IS approach be universally adopted to achieve deep energy savings.« less
Quantifying the benefits of a building retrofit using an integrated system approach: A case study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Regnier, Cynthia; Sun, Kaiyu; Hong, Tianzhen
Building retrofits provide a large opportunity to significantly reduce energy consumption in the buildings sector. Traditional building retrofits focus on equipment upgrades, often at the end of equipment life or failure, and result in replacement with marginally improved similar technology and limited energy savings. The Integrated System (IS) retrofit approach enables much greater energy savings by leveraging interactive effects between end use systems, enabling downsized or lower energy technologies. This work presents a case study in Hawaii quantifying the benefits of an IS retrofit approach compared to two traditional retrofit approaches: a Standard Practice of upgrading equipment to meet minimummore » code requirements, and an Improved Practice of upgrading equipment to a higher efficiency. The IS approach showed an energy savings of 84% over existing building energy use, much higher than the traditional approaches of 13% and 33%. The IS retrofit also demonstrated the greatest energy cost savings potential. While the degree of savings realized from the IS approach will vary by building and climate, these findings indicate that savings on the order of 50% and greater are not possible without an IS approach. It is therefore recommended that the IS approach be universally adopted to achieve deep energy savings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Stewart, James; Todd, Annika
Residential behavior-based (BB) programs use strategies grounded in the behavioral and social sciences to influence household energy use. These may include providing households with real-time or delayed feedback about their energy use; supplying energy efficiency education and tips; rewarding households for reducing their energy use; comparing households to their peers; and establishing games, tournaments, and competitions. BB programs often target multiple energy end uses and encourage energy savings, demand savings, or both. Savings from BB programs are usually a small percentage of energy use, typically less than 5 percent. Utilities will continue to implement residential BB programs as large-scale, randomizedmore » control trials (RCTs); however, some are now experimenting with alternative program designs that are smaller scale; involve new communication channels such as the web, social media, and text messaging; or that employ novel strategies for encouraging behavior change (for example, Facebook competitions). These programs will create new evaluation challenges and may require different evaluation methods than those currently employed to verify any savings they generate. Quasi-experimental methods, however, require stronger assumptions to yield valid savings estimates and may not measure savings with the same degree of validity and accuracy as randomized experiments.« less
Energy Savers: Tips on Saving Money & Energy at Home
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.
Energy Saver: Tips on Saving Money & Energy at Home
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.
Pan Am gets big savings at no cost
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanz, D.
Pan American World Airways' contract with an energy management control systems distributor enabled the company's terminal and maintenance facilities at JFK airport in New York to shift from housekeeping to major savings without additional cost. Energy savings from a pneumatic control system were split almost equally between Pan Am and Thomas S. Brown Associates (TSBA) Inc., and further savings are expected from a planned computer-controlled system. A full-time energy manager, able to give top priority to energy-consumption problems, was considered crucial to the program's success. Early efforts in light-level reduction and equipment scheduling required extensive persuasion and policing, but successfulmore » energy savings allowed the manager to progress to the more-extensive plants with TSBA.« less
Starostina, Vlada; Damgaard, Anders; Eriksen, Marie K; Christensen, Thomas H
2018-04-01
The current waste management system, handling around 500,000 t of household, commercial, and institutional waste annually in the Irkutsk region, Siberia, is based on landfilling in an old landfill with no controls of leachate and gas. Life-cycle assessment modelling of the current system shows that it is a major load on the environment, while the simulation of seven alternative systems results in large savings in many impact categories. With respect to climate change, it is estimated that a saving of about 1200 kg CO 2 equivalents is possible per year, per inhabitant, which is a significant reduction in greenhouse gas emissions. The best alternatives involve efficient energy recovery from waste and recycling by source separation for commercial and institutional waste, the major waste type in the Irkutsk region. Recycling of household waste seems less attractive, and it is therefore recommended only to consider this option after experience has been gained with the commercial and institutional waste. Sensitivity analysis shows that recovery of energy - in particular electricity, heat, and steam - from waste is crucial to the environmental performance of the waste management system. This relates to the efficiencies of energy recovery as well as what the recovered energy substitutes, that is, the 'dirtier' the off-set energy, the higher the environmental savings for the waste management system. Since recovered energy may be utilised by only a few energy grids or industrial users, it is recommended to perform additional local assessments of the integration of the waste energy into existing systems and facilities.
Saving Millions without Spending a Dime.
ERIC Educational Resources Information Center
Raman, Elizabeth
2003-01-01
Describes how the University of Hawaii at Hilo is using the $2.7 million it saved on utility bills during the past 5 years to repay campus energy improvements financed, installed, and maintained by an energy services company; the method is called energy savings performance contracting. (EV)
Improving Sustainability of Ion Implant Modules
NASA Astrophysics Data System (ADS)
Mayer, Jim
2011-01-01
Semiconductor fabs have long been pressured to manage capital costs, reduce energy consumption and increasingly improve efforts to recycle and recover resources. Ion implant tools have been high-profile offenders on all three fronts. They draw such large volumes of air for heat dissipation and risk reduction that historically, they are the largest consumer of cleanroom air of any process tool—and develop energy usage and resource profiles to match. This paper presents a documented approach to reduce their energy consumption and dramatically downsize on-site facilities support for cleanroom air manufacture and abatement. The combination produces significant capital expenditure savings. The case entails applying SAGS Type 1 (sub-atmospheric gas systems) toxic gas packaging to enable engineering adaptations that deliver the energy savings and cost benefits without any reduction in environmental health and safety. The paper also summarizes benefits as they relate to reducing a fabs carbon emission footprint (and longer range advantages relative to potential cap and trade programs) with existing technology.
Achieving Deeper Energy Savings in Federal Energy Performance Contracts
Shonder, John A.; Nasseri, Cyrus
2015-01-01
Legislation requires each agency of the US federal government to reduce the aggregate energy use index of its buildings by 30% by 2015, with respect to a 2003 baseline. The declining availability of appropriated funding means that energy performance contracting will be key to achieving this goal. Historically however, energy performance contracts have been able to reduce energy use by only about 20% over baseline. Achieving 30% energy reductions using performance contracting will require new approaches and a specific focus on achieving higher energy savings, both by ESCOs and by agencies. This paper describes some of the ways federal agenciesmore » are meeting this challenge, and presents results from the efforts of one agency the US General Services Administration -- to achieve deeper energy savings in conventional energy savings performance contracts.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2008-07-01
This case study describes how the Kaiser Aluminum plant in Sherman, Texas, achieved annual savings of $360,000 and 45,000 MMBtu, and improved furnace energy intensity by 11.1% after receiving a DOE Save Energy Now energy assessment and implementing recommendations to improve the efficiency of its process heating system.
Parade of Homes Display Features Energy-Saving Ideas
Parade of Homes Display Features Energy-Saving Ideas For more information contact: George Douglas Energy's (DOE) National Renewable Energy Laboratory will showcase energy efficient and solar energy ideas
Inclusion of cool roofs in nonresidential Title 24 prescriptive requirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levinson, Ronnen; Akbari, Hashem; Konopacki, Steve
2002-12-15
Roofs that have high solar reflectance (high ability to reflect sunlight) and high thermal emittance (high ability to radiate heat) tend to stay cool in the sun. The same is true of low-emittance roofs with exceptionally high solar reflectance. Substituting a cool roof for a noncool roof tends to decrease cooling electricity use, cooling power demand, and cooling-equipment capacity requirements, while slightly increasing heating energy consumption. Cool roofs can also lower the ambient air temperature in summer, slowing ozone formation and increasing human comfort. DOE-2.1E building energy simulations indicate that use of a cool roofing material on a prototypical Californiamore » nonresidential building with a low-sloped roof yields average annual cooling energy savings of approximately 300 kWh/1000 ft2 [3.2 kWh/m2], average annual natural gas deficits of 4.9 therm/1000 ft2 [5.6 MJ/m2], average source energy savings of 2.6 MBTU/1000 ft2 [30 MJ/m2], and average peak power demand savings of 0. 19 kW/1000 ft2 [2.1 W/m2]. The 15-year net present value (NPV) of energy savings averages $450/1000 ft2 [$4.90/m2] with time dependent valuation (TDV), and $370/1000 ft2 [$4.00/m2] without TDV. When cost savings from downsizing cooling equipment are included, the average total savings (15-year NPV + equipment savings) rises to $550/1000 ft2 [$5.90/m2] with TDV, and to $470/1000 ft2 [$5.00/m2] without TDV. Total savings range from 0.18 to 0.77 $/ft2 [1.90 to 8.30 $/m2] with TDV, and from 0.16 to 0.66 $/ft2 [1.70 to 7.10 $/m2] without TDV, across California's 16 climate zones. The typical cost premium for a cool roof is 0.00 to 0.20 $/ft2 [0.00 to 2.20 $/m2]. Cool roofs with premiums up to $0.20/ft2 [$2.20/m2] are expected to be cost effective in climate zones 2 through 16; those with premiums not exceeding $0.18/ft2 [$1.90/m2] are expected to be also cost effective in climate zone 1. Hence, this study recommends that the year-2005 California building energy efficiency code (Title 24, Pa rt 6 of the California Code of Regulations) for nonresidential buildings with low-sloped roofs include a cool-roof prescriptive requirement in all California climate zones. Buildings with roofs that do not meet prescriptive requirements may comply with the code via an ''overall-envelope'' approach (non-metal roofs only), or via a performance approach (all roof types).« less
10 CFR 810.16 - Effective date and savings clause.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Effective date and savings clause. 810.16 Section 810.16 Energy DEPARTMENT OF ENERGY ASSISTANCE TO FOREIGN ATOMIC ENERGY ACTIVITIES § 810.16 Effective date and savings clause. Except for actions that may be taken by DOE pursuant to § 810.11, the regulations in this...
10 CFR 810.16 - Effective date and savings clause.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Effective date and savings clause. 810.16 Section 810.16 Energy DEPARTMENT OF ENERGY ASSISTANCE TO FOREIGN ATOMIC ENERGY ACTIVITIES § 810.16 Effective date and savings clause. Except for actions that may be taken by DOE pursuant to § 810.11, the regulations in this...
10 CFR 810.16 - Effective date and savings clause.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Effective date and savings clause. 810.16 Section 810.16 Energy DEPARTMENT OF ENERGY ASSISTANCE TO FOREIGN ATOMIC ENERGY ACTIVITIES § 810.16 Effective date and savings clause. Except for actions that may be taken by DOE pursuant to § 810.11, the regulations in this...
10 CFR 810.16 - Effective date and savings clause.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Effective date and savings clause. 810.16 Section 810.16 Energy DEPARTMENT OF ENERGY ASSISTANCE TO FOREIGN ATOMIC ENERGY ACTIVITIES § 810.16 Effective date and savings clause. Except for actions that may be taken by DOE pursuant to § 810.11, the regulations in this...
10 CFR 810.16 - Effective date and savings clause.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Effective date and savings clause. 810.16 Section 810.16 Energy DEPARTMENT OF ENERGY ASSISTANCE TO FOREIGN ATOMIC ENERGY ACTIVITIES § 810.16 Effective date and savings clause. Except for actions that may be taken by DOE pursuant to § 810.11, the regulations in this...
Army Reserve Expands Net Zero Energy, Water, Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solana, Amy E.
In 2012, the Army initiated a Net Zero (NZ) program to establish NZ energy, water, and/or waste goals at installations across the U.S. In 2013, the U.S. Army Reserve expanded this program to cover all three categories at different types of Reserve Centers (RCs) across 5 regions. Projects identified at 10 pilot sites resulted in an average savings potential from recommended measures of 90% for energy, 60% for water, and 83% for waste. This article provides results of these efforts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shonder, John A; Hughes, Patrick
2006-01-01
Energy savings performance contracts (ESPCs) are a method of financing energy conservation projects using the energy cost savings generated by the conservation measures themselves. Ideally, reduced energy costs are visible as reduced utility bills, but in fact this is not always the case. On large military bases, for example, a single electric meter typically covers hundreds of individual buildings. Savings from an ESPC involving only a small number of these buildings will have little effect on the overall utility bill. In fact, changes in mission, occupancy, and energy prices could cause substantial increases in utility bills. For this reason, other,more » more practical, methods have been developed to measure and verify savings in ESPC projects. Nevertheless, increasing utility bills--when ESPCs are expected to be reducing them--are problematic and can lead some observers to question whether savings are actually being achieved. In this paper, the authors use utility bill analysis to determine energy, demand, and cost savings from an ESPC project that installed geothermal heat pumps in the family housing areas of the military base at Fort Polk, Louisiana. The savings estimates for the first year after the retrofits were found to be in substantial agreement with previous estimates that were based on submetered data. However, the utility bills also show that electrical use tended to increase as time went on. Since other data show that the energy use in family housing has remained about the same over the period, the authors conclude that the savings from the ESPC have persisted, and increases in electrical use must be due to loads unassociated with family housing. This shows that under certain circumstances, and with the proper analysis, utility bills can be used to estimate savings from ESPC projects. However, these circumstances are rare and over time the comparison may be invalidated by increases in energy use in areas unaffected by the ESPC.« less
Energy Savings Analysis of the Proposed Revision of the Washington D.C. Non-Residential Energy Code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, Michael I.; Athalye, Rahul A.; Hart, Philip R.
This report presents the results of an assessment of savings for the proposed Washington D.C. energy code relative to ASHRAE Standard 90.1-2010. It includes annual and life cycle savings for site energy, source energy, energy cost, and carbon dioxide emissions that would result from adoption and enforcement of the proposed code for newly constructed buildings in Washington D.C. over a five year period.
Teaching the Fundamentals of Energy Efficiency
NASA Astrophysics Data System (ADS)
Meier, Alan
2010-02-01
A course on energy efficiency is a surprisingly valuable complement to a student's education in physics and many other disciplines. The Univ. of California, Davis, offers a 1-quarter course on ``understanding the other side of the meter.'' Lectures begin by giving students a demand-side perspective on how, where, and why energy is used. Students measure energy use of appliances in their homes and then report results. This gives students a practical sense of the difference between energy and power and learn how appliances transform energy into useful services. Lectures introduce the types of direct conservation measures--reducing demand, reducing fixed consumptions, and increasing efficiency. Practical examples draw upon simple concepts in heat transfer, thermodynamics, and mechanics. Graphical techniques, strengthened through problem sets, explain the interdependence of conservation measures. Lectures then examine indirect energy savings from measures and consider questions like ``where can one achieve the greatest fuel savings in a car by removing one gram of mass?'' Finally, students learn about conservation measures that circumvent physical limits by adopting new processes. By the end of the course, students have a gained a new perspective on energy consumption and the opportunities to reduce it. )
Status and Opportunities for Improving the Consistency of Technical Reference Manuals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jayaweera, Tina; Velonis, Aquila; Haeri, Hossein
Across the United States, energy-efficiency program administrators rely on Technical Reference Manuals (TRMs) as sources for calculations and deemed savings values for specific, well-defined efficiency measures. TRMs play an important part in energy efficiency program planning by providing a common and consistent source for calculation of ex ante and often ex post savings. They thus help reduce energy-efficiency resource acquisition costs by obviating the need for extensive measurement and verification and lower performance risk for program administrators and implementation contractors. This paper considers the benefits of establishing region-wide or national TRMs and considers the challenges of such undertaking due tomore » the difficulties in comparing energy savings across jurisdictions. We argue that greater consistency across TRMs in the approaches used to determine deemed savings values, with more transparency about assumptions, would allow better comparisons in savings estimates across jurisdictions as well as improve confidence in reported efficiency measure savings. To support this thesis, we review approaches for the calculation of savings for select measures in TRMs currently in use in 17 jurisdictions. The review reveals differences in the saving methodologies, technical assumptions, and input variables used for estimating deemed savings values. These differences are described and their implications are summarized, using four, common energy-efficiency measures as examples. Recommendations are then offered for establishing a uniform approach for determining deemed savings values.« less
Longest-Serving Active Paper Mill in the Western United States Uncovers New Ways to Save Energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2008-03-01
This case study describes how West Linn Paper Company's coated paper mill in West Linn, Oregon, saves nearly 58,200 MMBtu and $379,000 annually after receiving a DOE Save Energy Now energy assessment and implementing those recommendations.
The public health benefits of insulation retrofits in existing housing in the United States
Levy, Jonathan I; Nishioka, Yurika; Spengler, John D
2003-01-01
Background Methodological limitations make it difficult to quantify the public health benefits of energy efficiency programs. To address this issue, we developed a risk-based model to estimate the health benefits associated with marginal energy usage reductions and applied the model to a hypothetical case study of insulation retrofits in single-family homes in the United States. Methods We modeled energy savings with a regression model that extrapolated findings from an energy simulation program. Reductions of fine particulate matter (PM2.5) emissions and particle precursors (SO2 and NOx) were quantified using fuel-specific emission factors and marginal electricity analyses. Estimates of population exposure per unit emissions, varying by location and source type, were extrapolated from past dispersion model runs. Concentration-response functions for morbidity and mortality from PM2.5 were derived from the epidemiological literature, and economic values were assigned to health outcomes based on willingness to pay studies. Results In total, the insulation retrofits would save 800 TBTU (8 × 1014 British Thermal Units) per year across 46 million homes, resulting in 3,100 fewer tons of PM2.5, 100,000 fewer tons of NOx, and 190,000 fewer tons of SO2 per year. These emission reductions are associated with outcomes including 240 fewer deaths, 6,500 fewer asthma attacks, and 110,000 fewer restricted activity days per year. At a state level, the health benefits per unit energy savings vary by an order of magnitude, illustrating that multiple factors (including population patterns and energy sources) influence health benefit estimates. The health benefits correspond to $1.3 billion per year in externalities averted, compared with $5.9 billion per year in economic savings. Conclusion In spite of significant uncertainties related to the interpretation of PM2.5 health effects and other dimensions of the model, our analysis demonstrates that a risk-based methodology is viable for national-level energy efficiency programs. PMID:12740041
Cimpan, Ciprian; Wenzel, Henrik
2013-07-01
Primary energy savings potential is used to compare five residual municipal solid waste treatment systems, including configurations with mechanical (MT) and mechanical-biological (MBT) pre-treatment, which produce waste-derived fuels (RDF and SRF), biogas and/or recover additional materials for recycling, alongside a system based on conventional mass burn waste-to-energy and ash treatment. To examine the magnitude of potential savings we consider two energy efficiency levels (state-of-the-art and best available technology), the inclusion/exclusion of heat recovery (CHP vs. PP) and three different background end-use energy production systems (coal condensing electricity and natural gas heat, Nordic electricity mix and natural gas heat, and coal CHP energy quality allocation). The systems achieved net primary energy savings in a range between 34 and 140 MJprimary/100 MJinput waste, in the different scenario settings. The energy footprint of transportation needs, pre-treatment and reprocessing of recyclable materials was 3-9.5%, 1-18% and 1-8% respectively, relative to total energy savings. Mass combustion WtE achieved the highest savings in scenarios with CHP production, nonetheless, MBT-based systems had similarly high performance if SRF streams were co-combusted with coal. When RDF and SRF was only used in dedicated WtE plants, MBT-based systems totalled lower savings due to inherent system losses and additional energy costs. In scenarios without heat recovery, the biodrying MBS-based system achieved the highest savings, on the condition of SRF co-combustion. As a sensitivity scenario, alternative utilisation of SRF in cement kilns was modelled. It supported similar or higher net savings for all pre-treatment systems compared to mass combustion WtE, except when WtE CHP was possible in the first two background energy scenarios. Recovery of plastics for recycling before energy recovery increased net energy savings in most scenario variations, over those of full stream combustion. Sensitivity to assumptions regarding virgin plastic substitution was tested and was found to mostly favour plastic recovery. Copyright © 2013 Elsevier Ltd. All rights reserved.
Evaluation and Selection of Renewable Energy Technologies for Highway Maintenance Facilities
NASA Astrophysics Data System (ADS)
Andrews, Taylor
The interest in renewable energy has been increasing in recent years as attempts to reduce energy costs as well the consumption of fossil fuels are becoming more common. Companies and organizations are recognizing the increasing reliance on limited fossil fuels' resources, and as competition and costs for these resources grow, alternative solutions are becoming more appealing. Many federally run buildings and associations also have the added pressure of meeting the mandates of federal energy policies that dictate specific savings or reductions. Federal highway maintenance facilities run by the Department of Transportation fall into this category. To help meet energy saving goals, an investigation into potential renewable energy technologies was completed for the Ohio Department of Transportation. This research examined several types of renewable energy technologies and the major factors that affect their performance and evaluated their potential for implementation at highway maintenance facilities. Facilities energy usage data were provided, and a facility survey and site visits were completed to enhance the evaluation of technologies and the suitability for specific projects. Findings and technology recommendations were presented in the form of selection matrices, which were designed to help make selections in future projects. The benefits of utilization of other tools such as analysis software and life cycle assessments were also highlighted. These selection tools were designed to be helpful guides when beginning the pursuit of a renewable energy technology for highway maintenance facilities, and can be applied to other similar building types and projects. This document further discusses the research strategies and findings as well as the recommendations that were made to the personnel overseeing Ohio's highway maintenance facilities.
Schmidt, Markus H; Swang, Theodore W; Hamilton, Ian M; Best, Janet A
2017-01-01
Metabolic rate reduction has been considered the mechanism by which sleep conserves energy, similar to torpor or hibernation. This mechanism of energy savings is in conflict with the known upregulation (compared to wake) of diverse functions during sleep and neglects a potential role in energy conservation for partitioning of biological operations by behavioral state. Indeed, energy savings as derived from state-dependent resource allocations have yet to be examined. A mathematical model is presented based on relative rates of energy deployment for biological processes upregulated during either wake or sleep. Using this model, energy savings from sleep-wake cycling over constant wakefulness is computed by comparing stable limit cycles for systems of differential equations. A primary objective is to compare potential energy savings derived from state-dependent metabolic partitioning versus metabolic rate reduction. Additionally, energy conservation from sleep quota and the circadian system are also quantified in relation to a continuous wake condition. As a function of metabolic partitioning, our calculations show that coupling of metabolic operations with behavioral state may provide comparatively greater energy savings than the measured decrease in metabolic rate, suggesting that actual energy savings derived from sleep may be more than 4-fold greater than previous estimates. A combination of state-dependent metabolic partitioning and modest metabolic rate reduction during sleep may enhance energy savings beyond what is achievable through metabolic partitioning alone; however, the relative contribution from metabolic partitioning diminishes as metabolic rate is decreased during the rest phase. Sleep quota and the circadian system further augment energy savings in the model. Finally, we propose that state-dependent resource allocation underpins both sleep homeostasis and the optimization of daily energy conservation across species. This new paradigm identifies an evolutionary selective advantage for the upregulation of central and peripheral biological processes during sleep, presenting a unifying construct to understand sleep function.
78 FR 20097 - Energy Savings Performance Contracts
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-03
... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy Energy Savings Performance Contracts AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of request for information (RFI). SUMMARY: The U.S. Department of Energy (DOE) seeks comments and information...
Energy Efficiency Resources to Support State Energy Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Office of Strategic Programs, Strategic Priorities and Impact Analysis Team
An early step for most energy efficiency planning is to identify and quantify energy savings opportunities, and then to understand how to access this potential. The U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy offers resources that can help with both of these steps. This fact sheet presents those resources. The resources are also available on the DOE State and Local Solution Center on the "Energy Efficiency: Savings Opportunities and Benefits" page: https://energy.gov/eere/slsc/energy-efficiency-savings-opportunities-and-benefits.
Energy-Saving Control of a Novel Hydraulic Drive System for Field Walking Robot
NASA Astrophysics Data System (ADS)
Fang, Delei; Shang, Jianzhong; Xue, Yong; Yang, Junhong; Wang, Zhuo
2018-01-01
To improve the efficiency of the hydraulic drive system in field walking robot, this paper proposed a novel hydraulic system based on two-stage pressure source. Based on the analysis of low efficiency of robot single-stage hydraulic system, the paper firstly introduces the concept and design of two-stage pressure source drive system. Then, the new hydraulic system energy-saving control is planned according to the characteristics of walking robot. The feasibility of the new hydraulic system is proved by the simulation of the walking robot squatting. Finally, the efficiencies of two types hydraulic system are calculated, indicating that the novel hydraulic system can increase the efficiency by 41.5%, which can contribute to enhance knowledge about hydraulic drive system for field walking robot.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Wei; Gowri, Krishnan; Lane, Michael D.
2009-09-28
This Technical Support Document (TSD) describes the process, methodology and assumptions for development of the 50% Energy Savings Design Technology Packages for Highway Lodging Buildings, a design guidance document intended to provide recommendations for achieving 50% energy savings in highway lodging properties over the energy-efficiency levels contained in ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings.
Investigating energy-saving potentials in the cloud.
Lee, Da-Sheng
2014-02-20
Collecting webpage messages can serve as a sensor for investigating the energy-saving potential of buildings. Focusing on stores, a cloud sensor system is developed to collect data and determine their energy-saving potential. The owner of a store under investigation must register online, report the store address, area, and the customer ID number on the electric meter. The cloud sensor system automatically surveys the energy usage records by connecting to the power company website and calculating the energy use index (EUI) of the store. Other data includes the chain store check, company capital, location price, and the influence of weather conditions on the store; even the exposure frequency of store under investigation may impact the energy usage collected online. After collecting data from numerous stores, a multi-dimensional data array is constructed to determine energy-saving potential by identifying stores with similarity conditions. Similarity conditions refer to analyzed results that indicate that two stores have similar capital, business scale, weather conditions, and exposure frequency on web. Calculating the EUI difference or pure technical efficiency of stores, the energy-saving potential is determined. In this study, a real case study is performed. An 8-dimensional (8D) data array is constructed by surveying web data related to 67 stores. Then, this study investigated the savings potential of the 33 stores, using a site visit, and employed the cloud sensor system to determine the saving potential. The case study results show good agreement between the data obtained by the site visit and the cloud investigation, with errors within 4.17%. Among 33 the samples, eight stores have low saving potentials of less than 5%. The developed sensor on the cloud successfully identifies them as having low saving potential and avoids wasting money on the site visit.
Investigating Energy-Saving Potentials in the Cloud
Lee, Da-Sheng
2014-01-01
Collecting webpage messages can serve as a sensor for investigating the energy-saving potential of buildings. Focusing on stores, a cloud sensor system is developed to collect data and determine their energy-saving potential. The owner of a store under investigation must register online, report the store address, area, and the customer ID number on the electric meter. The cloud sensor system automatically surveys the energy usage records by connecting to the power company website and calculating the energy use index (EUI) of the store. Other data includes the chain store check, company capital, location price, and the influence of weather conditions on the store; even the exposure frequency of store under investigation may impact the energy usage collected online. After collecting data from numerous stores, a multi-dimensional data array is constructed to determine energy-saving potential by identifying stores with similarity conditions. Similarity conditions refer to analyzed results that indicate that two stores have similar capital, business scale, weather conditions, and exposure frequency on web. Calculating the EUI difference or pure technical efficiency of stores, the energy-saving potential is determined. In this study, a real case study is performed. An 8-dimensional (8D) data array is constructed by surveying web data related to 67 stores. Then, this study investigated the savings potential of the 33 stores, using a site visit, and employed the cloud sensor system to determine the saving potential. The case study results show good agreement between the data obtained by the site visit and the cloud investigation, with errors within 4.17%. Among 33 the samples, eight stores have low saving potentials of less than 5%. The developed sensor on the cloud successfully identifies them as having low saving potential and avoids wasting money on the site visit. PMID:24561405
FLASTAR: Florida Alliance for Saving Taxes and Energy Resources. Final Report.
ERIC Educational Resources Information Center
Sherwin, John R.; Parker, Danny S.
A study of the Florida Public Building Loan Concept pilot program determined its effectiveness in helping to upgrade building energy systems. The pilot program, termed FLASTAR (Florida Alliance for Saving Taxes and Resources), involved the comprehensive metering of an elementary school to demonstrate energy savings potential after retrofitting…
Review of the Application of Green Building and Energy Saving Technology
NASA Astrophysics Data System (ADS)
Tong, Zhineng
2017-12-01
The use of energy-saving technologies in green buildings should run through the entire process of building design, construction and use, enabling green energy-saving technologies to maximize their effectiveness in construction. Realize the sustainable development of green building, reduce energy consumption, reduce people’s interference with the natural environment, suitable for people living in “green” building.
Is Passive or Active House Needed In Face of Global Warming?
NASA Astrophysics Data System (ADS)
Tamosaitis, Romualdas
2017-10-01
The article aims to determine how effective the stricter current requirements for the building envelope insolation are from the economic energy savings perspective. The article deals with a mathematical method for economic assessment of optimal building thermal insulation. The mathematical methods used in this article are based on evaluating the break-even point between the construction expenditures and the economic profit. Recent research shows that energy savings achieved solely through stricter standards applied to the building envelopes are limited in their ability to achieve maximum results. As the ratio of building volume to building envelope increases, further energy saving measures applied to the building envelope produce lower energy saving effects. Energy savings achieved using renewable energy resources, recuperation systems are much more effective. Research shows that much greater effect can be achieved by combining optimal building envelope energy efficiency measures with new requirements related to renewable energy sources and recuperating systems, such as solar batteries, wind turbines or heat pumps.
NASA Astrophysics Data System (ADS)
Gosman, Nathaniel
For energy utilities faced with expanded jurisdictional energy efficiency requirements and pursuing demand-side management (DSM) incentive programs in the large industrial sector, performance incentive programs can be an effective means to maximize the reliability of planned energy savings. Performance incentive programs balance the objectives of high participation rates with persistent energy savings by: (1) providing financial incentives and resources to minimize constraints to investment in energy efficiency, and (2) requiring that incentive payments be dependent on measured energy savings over time. As BC Hydro increases its DSM initiatives to meet the Clean Energy Act objective to reduce at least 66 per cent of new electricity demand with DSM by 2020, the utility is faced with a higher level of DSM risk, or uncertainties that impact the costeffective acquisition of planned energy savings. For industrial DSM incentive programs, DSM risk can be broken down into project development and project performance risks. Development risk represents the project ramp-up phase and is the risk that planned energy savings do not materialize due to low customer response to program incentives. Performance risk represents the operational phase and is the risk that planned energy savings do not persist over the effective measure life. DSM project development and performance risks are, in turn, a result of industrial economic, technological and organizational conditions, or DSM risk factors. In the BC large industrial sector, and characteristic of large industrial sectors in general, these DSM risk factors include: (1) capital constraints to investment in energy efficiency, (2) commodity price volatility, (3) limited internal staffing resources to deploy towards energy efficiency, (4) variable load, process-based energy saving potential, and (5) a lack of organizational awareness of an operation's energy efficiency over time (energy performance). This research assessed the capacity of alternative performance incentive program models to manage DSM risk in BC. Three performance incentive program models were assessed and compared to BC Hydro's current large industrial DSM incentive program, Power Smart Partners -- Transmission Project Incentives, itself a performance incentive-based program. Together, the selected program models represent a continuum of program design and implementation in terms of the schedule and level of incentives provided, the duration and rigour of measurement and verification (M&V), energy efficiency measures targeted and involvement of the private sector. A multi criteria assessment framework was developed to rank the capacity of each program model to manage BC large industrial DSM risk factors. DSM risk management rankings were then compared to program costeffectiveness, targeted energy savings potential in BC and survey results from BC industrial firms on the program models. The findings indicate that the reliability of DSM energy savings in the BC large industrial sector can be maximized through performance incentive program models that: (1) offer incentives jointly for capital and low-cost operations and maintenance (O&M) measures, (2) allow flexible lead times for project development, (3) utilize rigorous M&V methods capable of measuring variable load, process-based energy savings, (4) use moderate contract lengths that align with effective measure life, and (5) integrate energy management software tools capable of providing energy performance feedback to customers to maximize the persistence of energy savings. While this study focuses exclusively on the BC large industrial sector, the findings of this research have applicability to all energy utilities serving large, energy intensive industrial sectors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The report contains documentation in support of claims that the Toshiba Microwave Oven can cook any and all types of food satisfactorily with a 75% savings in energy usage and cost, regardless of the size of a household. (Portions of this document are not fully legible)
Schools + GHPs = Savings and Efficiency.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC.
The geothermal heat pump (GHP) is winning praise for its ability to help schools reduce energy costs while providing a clean, comfortable, quiet, and aesthetically pleasing heating and cooling capability. This pamphlet examines the benefits of installing a GHP system in new and existing school facilities, suggests the type of planning and…
David Grant Medical Center energy use baseline and integrated resource assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richman, E.E.; Hoshide, R.K.; Dittmer, A.L.
1993-04-01
The US Air Mobility Command (AMC) has tasked Pacific Northwest Laboratory (PNL) with supporting the US Department of Energy (DOE) Federal Energy Management Program`s (FEMP) mission to identify, evaluate, and assist in acquiring all cost-effective energy resource opportunities (EROs) at the David Grant Medical Center (DGMC). This report describes the methodology used to identify and evaluate the EROs at DGMC, provides a life-cycle cost (LCC) analysis for each ERO, and prioritizes any life-cycle cost-effective EROs based on their net present value (NPV), value index (VI), and savings to investment ratio (SIR or ROI). Analysis results are presented for 17 EROsmore » that involve energy use in the areas of lighting, fan and pump motors, boiler operation, infiltration, electric load peak reduction and cogeneration, electric rate structures, and natural gas supply. Typical current energy consumption is approximately 22,900 MWh of electricity (78,300 MBtu), 87,600 kcf of natural gas (90,300 MBtu), and 8,300 gal of fuel oil (1,200 MBtu). A summary of the savings potential by energy-use category of all independent cost-effective EROs is shown in a table. This table includes the first cost, yearly energy consumption savings, and NPV for each energy-use category. The net dollar savings and NPV values as derived by the life-cycle cost analysis are based on the 1992 federal discount rate of 4.6%. The implementation of all EROs could result in a yearly electricity savings of more than 6,000 MWh or 26% of current yearly electricity consumption. More than 15 MW of billable load (total billed by the utility for a 12-month period) or more than 34% of current billed demand could also be saved. Corresponding natural gas savings would be 1,050 kcf (just over 1% of current consumption). Total yearly net energy cost savings for all options would be greater than $343,340. This value does not include any operations and maintenance (O&M) savings.« less
David Grant Medical Center energy use baseline and integrated resource assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richman, E.E.; Hoshide, R.K.; Dittmer, A.L.
1993-04-01
The US Air Mobility Command (AMC) has tasked Pacific Northwest Laboratory (PNL) with supporting the US Department of Energy (DOE) Federal Energy Management Program's (FEMP) mission to identify, evaluate, and assist in acquiring all cost-effective energy resource opportunities (EROs) at the David Grant Medical Center (DGMC). This report describes the methodology used to identify and evaluate the EROs at DGMC, provides a life-cycle cost (LCC) analysis for each ERO, and prioritizes any life-cycle cost-effective EROs based on their net present value (NPV), value index (VI), and savings to investment ratio (SIR or ROI). Analysis results are presented for 17 EROsmore » that involve energy use in the areas of lighting, fan and pump motors, boiler operation, infiltration, electric load peak reduction and cogeneration, electric rate structures, and natural gas supply. Typical current energy consumption is approximately 22,900 MWh of electricity (78,300 MBtu), 87,600 kcf of natural gas (90,300 MBtu), and 8,300 gal of fuel oil (1,200 MBtu). A summary of the savings potential by energy-use category of all independent cost-effective EROs is shown in a table. This table includes the first cost, yearly energy consumption savings, and NPV for each energy-use category. The net dollar savings and NPV values as derived by the life-cycle cost analysis are based on the 1992 federal discount rate of 4.6%. The implementation of all EROs could result in a yearly electricity savings of more than 6,000 MWh or 26% of current yearly electricity consumption. More than 15 MW of billable load (total billed by the utility for a 12-month period) or more than 34% of current billed demand could also be saved. Corresponding natural gas savings would be 1,050 kcf (just over 1% of current consumption). Total yearly net energy cost savings for all options would be greater than $343,340. This value does not include any operations and maintenance (O M) savings.« less
NASA Astrophysics Data System (ADS)
Boudet, Hilary; Ardoin, Nicole M.; Flora, June; Armel, K. Carrie; Desai, Manisha; Robinson, Thomas N.
2016-08-01
Energy education programmes for children are hypothesized to have great potential to save energy. Such interventions are often assumed to impact child and family behaviours. Here, using a cluster-randomized controlled trial with 30 Girl Scout troops in Northern California, we assess the efficacy of two social cognitive theory-based interventions focused on residential and food-and-transportation energy-related behaviours of Girl Scouts and their families. We show that Girl Scouts and parents in troops randomly assigned to the residential energy intervention significantly increased their self-reported residential energy-saving behaviours immediately following the intervention and after more than seven months of follow-up, compared with controls. Girl Scouts in troops randomly assigned to the food-and-transportation energy intervention significantly increased their self-reported food-and-transportation energy-saving behaviours immediately following the intervention, compared with controls, but not at follow-up. The results demonstrate that theory-based, child-focused energy interventions have the potential to increase energy-saving behaviours among both children and their parents.
NASA Astrophysics Data System (ADS)
Alaelddin, Fuad Yousif Mohammed; Newaz, S. H. Shah; Lee, Joohyung; Uddin, Mohammad Rakib; Lee, Gyu Myoung; Choi, Jun Kyun
2015-12-01
The majority of the traffic over the Internet is TCP based, which is very sensitive to packet loss and delay. Existing research efforts in TDM-Passive Optical Networks (TDM-PONs) mostly evaluate energy saving and traffic delay performances under different energy saving solutions. However, to the best of our knowledge, how energy saving mechanisms could affect TCP traffic performance in TDM-PONs has hardly been studied. In this paper, by means of our state-of-art OPNET Modular based TDM-PON simulator, we evaluate TCP traffic delay, throughput, and Optical Network Unit (ONU) energy consumption performances in a TDM-PON where energy saving mechanisms are employed in ONUs. Here, we study the performances under commonly used energy saving mechanisms defined in standards for TDM-PONs: cyclic sleep and doze mode. In cyclic sleep mode, we evaluate the performances under two well-known sleep interval length deciding algorithms (i.e. fixed sleep interval (FSI) and exponential sleep interval deciding (ESID)) that an OLT uses to decide sleep interval lengths for an ONU. Findings in this paper put forward the strong relationship among TCP traffic delay, throughput and ONU energy consumption under different sleep interval lengths. Moreover, we reveal that under high TCP traffic, both FSI and ESID will end up showing similar delay, energy and throughput performance. Our findings also show that doze mode can offer better TCP throughput and delay performance at the price of consuming more energy than cyclic sleep mode. In addition, our results provide a glimpse on understanding at what point doze mode becomes futile in improving energy saving of an ONU under TCP traffic. Furthermore, in this paper, we highlight important research issues that should be studied in future research to maximize energy saving in TDM-PONs while meeting traffic Quality of Service requirements.
NASA Astrophysics Data System (ADS)
Li, Jin; Qiu, Zhiling; Hu, Leilei
2018-04-01
The inverter-based regenerative braking power utilization devices can re-utilize the regenerative energy, thus reduce the energy consumption of urban rail transit. In this paper the power absorption principle of the inverter-based device is introduced, then the key influencing factors of energy saving performance are analyzed based on the absorption model. The field operation data verified that the control DC voltage plays an important role and lower control DC voltage yields more energy saving. Also, the one year energy saving performance data of an inverter-based re-utilization device located in NanJing S8 line is provided, and more than 1.2 million kWh energy is recovered in the one year operation.
Chen, Xiding; Huang, Qinghua; Huang, Weilun; Li, Xue
2018-02-08
We investigated the impact of a sustainable development technology on the macroeconomic variables in a small economy utilizing a case study with a stochastically improving energy saving technology and a stochastically increasing energy price. The results show the technological displacement effects of energy saving technology are stronger, but there are more ambiguous instantaneous returns to physical capital. However, the energy saving technology's displacement effects might not affect the conditions under which the Harberger-Laursen-Metzler (HLM) effect holds. The effects of rising energy prices on bonds are stronger, and there are more ambiguous instantaneous returns, but the conditions under which the HLM effect holds are different.
Cascade Apartments: Deep Energy Multifamily Retrofit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, A.; Mattheis, L.; Kunkle, R.
2014-02-01
In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions : 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofitmore » package after considering utility window incentives and KCHA capitol improvement funding.« less
Cascade Apartments - Deep Energy Multifamily Retrofit , Kent, Washington (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2014-02-01
In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions : 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofitmore » package after considering utility window incentives and KCHA capitol improvement funding.« less
Cascade Apartments: Deep Energy Multifamily Retrofit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, A.; Mattheis, L.; Kunkle, R.
2014-02-01
In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions: 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit packagemore » after considering utility window incentives and KCHA capitol improvement funding.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucas, Robert G.; Taylor, Zachary T.; Mendon, Vrushali V.
2012-07-03
The 2012 International Energy Conservation Code (IECC) yields positive benefits for Michigan homeowners. Moving to the 2012 IECC from the Michigan Uniform Energy Code is cost-effective over a 30-year life cycle. On average, Michigan homeowners will save $10,081 with the 2012 IECC. Each year, the reduction to energy bills will significantly exceed increased mortgage costs. After accounting for up-front costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $604 for the 2012 IECC.
Huang, Qinghua; Huang, Weilun; Li, Xue
2018-01-01
We investigated the impact of a sustainable development technology on the macroeconomic variables in a small economy utilizing a case study with a stochastically improving energy saving technology and a stochastically increasing energy price. The results show the technological displacement effects of energy saving technology are stronger, but there are more ambiguous instantaneous returns to physical capital. However, the energy saving technology’s displacement effects might not affect the conditions under which the Harberger-Laursen-Metzler (HLM) effect holds. The effects of rising energy prices on bonds are stronger, and there are more ambiguous instantaneous returns, but the conditions under which the HLM effect holds are different. PMID:29419788
NASA Astrophysics Data System (ADS)
Mottaeva, Angela
2017-10-01
Article is devoted to the consideration of the existing approaches to energy saving. According to the author’s opinion,the system approach is not enough for the achievement of the goal of the increase in energy efficiency and economy of energy, which is quite relevant for the world scientific community today, when the mankind has reached the certain power and ecological threshold. The author reasons the need of programme-and-target approach to energy saving and the increase in energy efficiency of buildings. The problems of the energy saving in current conditions are revealed. The provisional algorithm of the programme-and-target approach to energy efficiency. The expected results from introduction of the programme-and-target approach are presented in the article.
Estimating customer electricity savings from projects installed by the U.S. ESCO industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carvallo, Juan Pablo; Larsen, Peter H.; Goldman, Charles A.
The U.S. energy service company (ESCO) industry has a well-established track record of delivering substantial energy and dollar savings in the public and institutional facilities sector, typically through the use of energy savings performance contracts (ESPC) (Larsen et al. 2012; Goldman et al. 2005; Hopper et al. 2005, Stuart et al. 2013). This ~$6.4 billion industry, which is expected to grow significantly over the next five years, may play an important role in achieving demand-side energy efficiency under local/state/federal environmental policy goals. To date, there has been little or no research in the public domain to estimate electricity savings formore » the entire U.S. ESCO industry. Estimating these savings levels is a foundational step in order to determine total avoided greenhouse gas (GHG) emissions from demand-side energy efficiency measures installed by U.S. ESCOs. We introduce a method to estimate the total amount of electricity saved by projects implemented by the U.S. ESCO industry using the Lawrence Berkeley National Laboratory (LBNL) /National Association of Energy Service Companies (NAESCO) database of projects and LBNL’s biennial industry survey. We report two metrics: incremental electricity savings and savings from ESCO projects that are active in a given year (e.g., 2012). Overall, we estimate that in 2012 active U.S. ESCO industry projects generated about 34 TWh of electricity savings—15 TWh of these electricity savings were for MUSH market customers who did not rely on utility customer-funded energy efficiency programs (see Figure 1). This analysis shows that almost two-thirds of 2012 electricity savings in municipal, local and state government facilities, universities/colleges, K-12 schools, and healthcare facilities (i.e., the so-called “MUSH” market) were not supported by a utility customer-funded energy efficiency program.« less
Building energy information systems: Synthesis of costs, savings, and best-practice uses
Granderson, Jessica; Lin, Guanjing
2016-02-19
Building energy information systems (EIS) are a powerful customer-facing monitoring and analytical technology that can enable up to 20% site energy savings for buildings. Few technologies are as heavily marketed, but in spite of their potential, EIS remain an under-adopted emerging technology. One reason is the lack of information on purchase costs and associated energy savings. While insightful, the growing body of individual case studies has not provided industry the information needed to establish the business case for investment. Vastly different energy and economic metrics prevent generalizable conclusions. This paper addresses three common questions concerning EIS use: what are themore » costs, what have users saved, and which best practices drive deeper savings? We present a large-scale assessment of the value proposition for EIS use based on data from over two-dozen organizations. Participants achieved year-over-year median site and portfolio savings of 17% and 8%, respectively; they reported that this performance would not have been possible without the EIS. The median five-year cost of EIS software ownership (up-front and ongoing costs) was calculated to be $1,800 per monitoring point (kilowatt meter points were most common), with a median portfolio-wide implementation size of approximately 200 points. In this paper, we present an analysis of the relationship between key implementation factors and achieved energy reductions. Extent of efficiency projects, building energy performance prior to EIS installation, depth of metering, and duration of EIS were strongly correlated with greater savings. As a result, we also identify the best practices use of EIS associated with greater energy savings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyers, Stephen; Williams, Alison; Chan, Peter
This paper presents estimates of the key impacts of Federal energy and water conservation standards adopted from 1987 through 2015. The standards for consumer products and commercial and industrial equipment include those set by legislation as well as standards adopted by DOE through rulemaking. In 2015, the standards saved an estimated 4.49 quads of primary energy, which is equivalent to 5% of total U.S. energy consumption. The savings in operating costs for households and businesses totaled $63.4 billion. The average household saved $320 in operating costs as a result of residential appliance standards. The estimated reduction in CO2 emissions associatedmore » with the standards in 2015 was 238 million metric tons, which is equivalent to 4.3% of total U.S. CO2 emissions. The estimated cumulative energy savings over the period 1990-2090 amount to 216.9 quads. Accounting for the increased upfront costs of more-efficient products and the operating cost (energy and water) savings over the products’ lifetime, the standards have a cumulative net present value (NPV) of consumer benefit of between $1,627 billion and $1,887 billion, using 7 percent and 3 percent discount rates, respectively. The water conservation standards, together with energy conservation standards that also save water, reduced water use by 1.9 trillion gallons in 2015 and estimated cumulative water savings by 2090 amount to 55 trillion gallons. The estimated consumer savings in 2015 from reduced water use amounted to $12 billon.« less
Building energy information systems: Synthesis of costs, savings, and best-practice uses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Granderson, Jessica; Lin, Guanjing
Building energy information systems (EIS) are a powerful customer-facing monitoring and analytical technology that can enable up to 20% site energy savings for buildings. Few technologies are as heavily marketed, but in spite of their potential, EIS remain an under-adopted emerging technology. One reason is the lack of information on purchase costs and associated energy savings. While insightful, the growing body of individual case studies has not provided industry the information needed to establish the business case for investment. Vastly different energy and economic metrics prevent generalizable conclusions. This paper addresses three common questions concerning EIS use: what are themore » costs, what have users saved, and which best practices drive deeper savings? We present a large-scale assessment of the value proposition for EIS use based on data from over two-dozen organizations. Participants achieved year-over-year median site and portfolio savings of 17% and 8%, respectively; they reported that this performance would not have been possible without the EIS. The median five-year cost of EIS software ownership (up-front and ongoing costs) was calculated to be $1,800 per monitoring point (kilowatt meter points were most common), with a median portfolio-wide implementation size of approximately 200 points. In this paper, we present an analysis of the relationship between key implementation factors and achieved energy reductions. Extent of efficiency projects, building energy performance prior to EIS installation, depth of metering, and duration of EIS were strongly correlated with greater savings. As a result, we also identify the best practices use of EIS associated with greater energy savings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyers, Stephen; Williams, Alison; Chan, Peter
This paper presents estimates of the key impacts of Federal energy and water conservation standards adopted from 1987 through 2013. The standards for consumer products and commercial and industrial equipment include those set by legislation as well as standards adopted by DOE through rulemaking. In 2013, the standards saved an estimated 4.05 quads of primary energy, which is equivalent to 4% of total U.S. energy consumption. The savings in operating costs for households and businesses totaledmore » $56 billion. The average household saved $$361 in operating costs as a result of residential and plumbing product standards. The estimated reduction in CO{sub 2} emissions associated with the standards in 2013 was 218 million metric tons, which is equivalent to 4% of total U.S. CO{sub 2} emissions. The estimated cumulative energy savings over the period 1990-2090 amount to 181 quads. Accounting for the increased upfront costs of more-efficient products and the operating cost (energy and water) savings over the products’ lifetime, the standards have a past and projected cumulative net present value (NPV) of consumer benefit of between $$1,271 billion and $1,487 billion, using 7 percent and 3 percent discount rates, respectively. The water conservation standards, together with energy conservation standards that also save water, reduced water use by 1.9 trillion gallons in 2013, and will achieve cumulative water savings by 2090 of 55 trillion gallons. The estimated consumer savings in 2013 from reduced water use amounted to $16 billon.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyers, Stephen; Williams, Alison; Chan, Peter
This paper presents estimates of the key impacts of Federal energy and water conservation standards adopted from 1987 through 2012. The standards for consumer products and commercial and industrial equipment include those set by legislation as well as standards adopted by DOE through rulemaking. In 2012, the standards saved an estimated 3.6 quads of primary energy, which is equivalent to 3% of total U.S. energy consumption. The savings in operating costs for households and businesses totaled $51.4 billion. The average household saved $347 in operating costs as a result of residential and plumbing product standards. The estimated reduction in CO2more » emissions associated with the standards in 2012 was 198 million metric tons, which is equivalent to 3% of total U.S. CO2 emissions. The estimated cumulative energy savings over the period 1990-2070 amount to 179 quads. Accounting for the increased upfront costs of more-efficient products and the operating cost (energy and water) savings over the products’ lifetime, the standards have a past and projected cumulative net present value (NPV) of consumer benefit of between $1,104 billion and $1,390 billion, using 7 percent and 3 percent discount rates, respectively. The water conservation standards, together with energy conservation standards that also save water, reduced water use by 1.8 trillion gallons in 2012, and will achieve cumulative water savings by 2040 of 54 trillion gallons. The estimated consumer savings in 2012 from reduced water use amounted to $13 billon.« less
After-hours power status of office equipment and energy use of miscellaneous plug-load equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.
2004-05-27
This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of miscellaneous plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers.more » For most types of miscellaneous equipment, we also estimated typical unit energy consumption in order to estimate total energy consumption of the miscellaneous devices within our sample. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from sixteen commercial buildings in California, Georgia, and Pennsylvania: four education buildings, two medical buildings, two large offices (> 500 employees each), three medium offices (50-500 employees each), and five small business offices (< 50 employees each). Two buildings are in the San Francisco Bay are a of California, nine (including the five small businesses) are in Pittsburgh, Pennsylvania, and five are in Atlanta, Georgia.« less
Computing with a single qubit faster than the computation quantum speed limit
NASA Astrophysics Data System (ADS)
Sinitsyn, Nikolai A.
2018-02-01
The possibility to save and process information in fundamentally indistinguishable states is the quantum mechanical resource that is not encountered in classical computing. I demonstrate that, if energy constraints are imposed, this resource can be used to accelerate information-processing without relying on entanglement or any other type of quantum correlations. In fact, there are computational problems that can be solved much faster, in comparison to currently used classical schemes, by saving intermediate information in nonorthogonal states of just a single qubit. There are also error correction strategies that protect such computations.
ERIC Educational Resources Information Center
Eccli, Eugene; And Others
This publication is a collection of inexpensive energy saving tips and home improvements for home owners, particularly in low-income areas or in older homes. Section titles are: (1) Keeping Warm; (2) Getting Heat Where You Need It; (3) Using the Sun; (4) Furnaces, Stoves, and Fireplaces; (5) Insulation and Other Energy Needs; (6) Do-It-Yourself…
Energy Savings Forecast of SSL in General Illumination Report Summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2016-09-30
Summary of the DOE report Energy Savings Forecast of Solid-State Lighting in General Illumination Applications, a biannual report that models the adoption of LEDs in the U.S. general-lighting market, along with associated energy savings, based on the full potential DOE has determined to be technically feasible over time.
ERIC Educational Resources Information Center
Fazio, James R., Ed.
1991-01-01
This document might easily have been called "How To Use Trees To Save Energy". It presents the energy saving advantages of landscaping the home and community with trees. The discussion includes: (1) landscaping advice to obtain the benefits of tree shade; (2) the heat island phenomenon in cities; (3) how and where to properly plant trees for…
Longest-Serving Active Paper Mill in the Western United States Uncovers New Ways to Save Energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2008-03-01
This case study describes how West Linn Paper Company's coated paper mill in West Linn, Oregon, saves nearly 58,200 MMBtu and $379,000 annually after receiving a DOE Save Energy Now energy assessment and implementing recommendations to improve the efficiency of its steam system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucas, Robert G.; Taylor, Zachary T.; Mendon, Vrushali V.
2012-04-01
The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Minnesota homeowners. Moving to either the 2009 or 2012 IECC from the current Minnesota Residential Energy Code is cost effective over a 30-year life cycle. On average, Minnesota homeowners will save $1,277 over 30 years under the 2009 IECC, with savings still higher at $9,873 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceed cumulative cash outlays) in 3 years for the 2009 IECC and 1 year for themore » 2012 IECC. Average annual energy savings are $122 for the 2009 IECC and $669 for the 2012 IECC.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKane, Aimee; Scheihing, Paul; Williams, Robert
2007-07-01
More than fifteen years after the launch of programs in theU.K. and U.S., industry still offers one of the largest opportunities forenergy savings worldwide. The International Energy Agency (IEA) estimatesthe savings potential from cost-optimization of industrial motor-drivensystems alone at 7 percent of global electricity use. The U.S. Departmentof Energy (USDOE) Industrial Technologies Program estimates 7 percentsavings potential in total US industrial energy use through theapplication of proven best practice. Simple paybacks for these types ofprojects are frequently two years or less. The technology required toachieve these savings is widely available; the technical skills requiredto identify energy saving opportunities are knownmore » and transferable.Although programs like USDOE's Best Practices have been highlysuccessful, most plants, as supported by 2002 MECS data, remain eitherunaware or unmotivated to improve their energy efficiency--as evidencedby the 98 percent of US industrial facilities reporting to MECS say thatthey lack a full-time energy manager. With the renewed interest in energyefficiency worldwide and the emergence of carbon trading and newfinancial instruments such as white certificates1, there is a need tointroduce greater transparency into the way that industrial facilitiesidentify, develop, and document energy efficiency projects. Historically,industrial energy efficiency projects have been developed by plantengineers, frequently with assistance from consultants and/or supplierswith highly specialized technical skills. Under this scenario,implementation of energy efficiency improvements is dependent onindividuals. These individuals typically include "champions" within anindustrial facility or corporation, working in cooperation withconsultants or suppliers who have substantial knowledge based on years ofexperience. This approach is not easily understood by others without thisspecialized technical knowledge, penetrates the market fairly slowly, andhas no assurance of persistence, since champions may leave the company orbe reassigned after project completion.This paper presents an alternatescenario that builds on the body of expert knowledge concerning energymanagement best practices and the experience of industrial champions toengage industry in continuous energy efficiency improvement at thefacility rather than the individual level. Under this scenario,standardized methodologies for applying and validating energy managementbest practices in industrial facilities will be developed through aconsensus process involving both plant personnel and specializedconsultants and suppliers. The resulting protocols will describe aprocess or framework for conducting an energy savings assessment andverifying the results that will be transparent to policymakers, managers,and the financial community, and validated by a third-party organization.Additionally, a global dialogue is being initiated by the United NationsIndustrial Development Organization (UNIDO) concerning the development ofan international industrial energy management standard that would be ISOcompatible. The proposed scenario will combine the resulting standardwith the best practice protocols for specific energy systems (i.e.,steam, process heating, compressed air, pumping systems, etc.) to formthe foundation of a third party, performance-based certification programfor the overall industrial facility that is compatible with existingmanagement systems, including ISO 9001:2000, 14001:2004 and 6 Sigma. Thelong term goal of this voluntary, industry designed certification programis to develop a transparent, globally accepted system for validatingenergy efficiency projects and management practices. This system wouldcreate a verified record of energy savings with potential market valuethat could be recognized among sectors and countries.« less
A Summary of Research on Energy Saving and Emission Reduction of Transportation
NASA Astrophysics Data System (ADS)
Cheng, Dongxiang; Wu, Lufen
2017-12-01
Road transport is an important part of transportation, and road in the field of energy-saving emission reduction is a very important industry. According to the existing problems of road energy saving and emission reduction, this paper elaborates the domestic and international research on energy saving and emission reduction from three aspects: road network optimization, pavement material and pavement maintenance. Road network optimization may be overlooked, and the research content is still relatively preliminary; pavement materials mainly from the asphalt pavement temperature mixed asphalt technology research; pavement maintenance technology development is relatively comprehensive.
NASA Astrophysics Data System (ADS)
Wiryadinata, Steven
Service life modeling was performed to gage the viability of unitary 3.5 kWt, ground-source terminal heat pumps (GTHP) employing horizontal directionally drilled geothermal heat exchangers (GHX) over air-source terminal heat pumps (PTHP) in hotels and motels and residential apartment building sectors in California's coastal and inland climates. Results suggest the GTHP can reduce hourly peak demand for the utility by 7%-25% compared to PTHP, depending on the climate and building type. The annual energy savings, which range from -1% to 5%, are highly dependent on the GTHP pump energy use relative to the energy savings attributed to the difference in ground and air temperatures (DeltaT). In mild climates with small ?T, the pump energy use may overcome any advantage to utilizing a GHX. The majority of total levelized cost savings - ranging from 0.18/ft2 to 0.3/ft 2 - are due to reduced maintenance and lifetime capital cost normally associated with geothermal heat pump systems. Without these reductions (not validated for the GTHP system studied), the GTHP technology does not appear to offer significant advantages over PTHP in the climate zones studied here. The GTHP levelized cost was most sensitive to variations in installed cost and in some cases, energy use (influenced by climate zone choice), which together highlights the importance of climate selection for installation, and the need for larger market penetration of ground-source systems in order to bring down installed costs as the technology matures.
A Compendium of Energy Conservation: Success Stories 90
DOE R&D Accomplishments Database
1990-12-01
The Department of Energy's (DOE) Office of Conservation and Renewable Energy proudly presents this summary of some its most successful projects and activities. The projects included in this document have made significant contributions to improving energy efficiency and fuel flexibility in the United States. The energy savings that can be realized from these projects are considerable. Americans have shown an impressive ability to reduce energy consumption since 1973. Studies show that 34 quadrillion Btus (quads) of energy were saved in 1988 alone as a result of energy conservation and other factors. These savings, worth approximately $180 billion, represent more energy than the United States obtains from any other single source. The availability of new, energy-efficient technologies has been an important ingredient in achieving these savings. Federal efforts to develop and commercialize energy-saving technologies and processes are a part of the reason for this progress. Over the past 10 years, DOE has carefully invested more than $2 billion in hundreds of research and development (R&D) projects to ensure the availability of advanced technology in the marketplace. These energy-efficient projects are carried out through DOE's Office of Conservation and Renewable Energy and reflect opportunities in the three energy-consuming, end-use sectors of the economy: buildings, transportation, and industry.
R and D of energy saving and new energy utilization in Japanese marine engineering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isshiki, N.; Murayama, Y.; Tamaki, H.
1982-08-01
As well known, Japanese shipbuilding and marine engineering industry has been one of the biggest in the world, and a lot of efforts have been made on energy saving and new energy development for the last several years, resulting in production of quite economical and energy saving ships and marine engines using all kinds of possible engineering methods. Also much promising research utilizing oceanic energy is under way for the ships of post-oil future. In this paper, first, the remarkable developments of energy saving in conventional marine engines and ship hulls, especially in diesel ships, in Japan are shown. Then,more » some studies on future marine engine systems and utilization of oceanic energy represented by ''Shin Aitoku Maru'' and other research on future windmill ships are described.« less
10 CFR 436.21 - Savings-to-investment ratio.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Savings-to-investment ratio. 436.21 Section 436.21 Energy... Procedures for Life Cycle Cost Analyses § 436.21 Savings-to-investment ratio. The savings-to-investment ratio... conservation measure. The denominator of the ratio is the present value of the net increase in investment and...
10 CFR 436.21 - Savings-to-investment ratio.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Savings-to-investment ratio. 436.21 Section 436.21 Energy... Procedures for Life Cycle Cost Analyses § 436.21 Savings-to-investment ratio. The savings-to-investment ratio... conservation measure. The denominator of the ratio is the present value of the net increase in investment and...
Time-varying value of electric energy efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mims, Natalie A.; Eckman, Tom; Goldman, Charles
Electric energy efficiency resources save energy and may reduce peak demand. Historically, quantification of energy efficiency benefits has largely focused on the economic value of energy savings during the first year and lifetime of the installed measures. Due in part to the lack of publicly available research on end-use load shapes (i.e., the hourly or seasonal timing of electricity savings) and energy savings shapes, consideration of the impact of energy efficiency on peak demand reduction (i.e., capacity savings) has been more limited. End-use load research and the hourly valuation of efficiency savings are used for a variety of electricity planningmore » functions, including load forecasting, demand-side management and evaluation, capacity and demand response planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service. This study reviews existing literature on the time-varying value of energy efficiency savings, provides examples in four geographically diverse locations of how consideration of the time-varying value of efficiency savings impacts the calculation of power system benefits, and identifies future research needs to enhance the consideration of the time-varying value of energy efficiency in cost-effectiveness screening analysis. Findings from this study include: -The time-varying value of individual energy efficiency measures varies across the locations studied because of the physical and operational characteristics of the individual utility system (e.g., summer or winter peaking, load factor, reserve margin) as well as the time periods during which savings from measures occur. -Across the four locations studied, some of the largest capacity benefits from energy efficiency are derived from the deferral of transmission and distribution system infrastructure upgrades. However, the deferred cost of such upgrades also exhibited the greatest range in value of all the components of avoided costs across the locations studied. -Of the five energy efficiency measures studied, those targeting residential air conditioning in summer-peaking electric systems have the most significant added value when the total time-varying value is considered. -The increased use of rooftop solar systems, storage, and demand response, and the addition of electric vehicles and other major new electricity-consuming end uses are anticipated to significantly alter the load shape of many utility systems in the future. Data used to estimate the impact of energy efficiency measures on electric system peak demands will need to be updated periodically to accurately reflect the value of savings as system load shapes change. -Publicly available components of electric system costs avoided through energy efficiency are not uniform across states and utilities. Inclusion or exclusion of these components and differences in their value affect estimates of the time-varying value of energy efficiency. -Publicly available data on end-use load and energy savings shapes are limited, are concentrated regionally, and should be expanded.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1987-10-22
This Energy Savings Opportunity Survey (ESOS) was performed for sixteen (16) buildings at Walter Reed Army Medical Center (WPAMC) in Washington, D.C. This survey was intended to reevaluate and update projects from a previous Energy Engineering Analysis Program (EEAP) survey performed at WRAMC. However, the previous EEAP survey was determined by the contracting officer to be incomplete and not worthy of further consideration. Therefore, this survey involved the complete reevaluation of the buildings to determine their potential energy cost savings. Six (6) projects and nine (9) low cost/no cost energy conservation opportunities (ECO`s) are recommended for implementation in the buildings.more » These projects and ECO`s are projected to annually save $448,263 at an implementation cost of $891,659. The simple payback (i.e., implementation cost divided by cost savings) for the recommendations in the survey is 1.99 years. The two (2) projects with the greatest cost savings are a stack heat recovery system (Project Number 5) and HVAC modifications (Project Number 1). These two (2) projects will provide 67% of the projected total savings for the survey. The sixteen (16) buildings in this survey represent only 22% of the total floor area of the Walter Reed Army Medical Center complex. It is believed that significant potential energy cost savings amounting to two (2) million dollars may be achieved in the remaining buildings in the complex not included in this survey. Specifically it is believed the main hospital building contains many opportunities for substantial cost savings.« less
Low-Emissivity, Energy-Control, Retrofit Window Film: Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winckler, Lisa
Solutia Performance Films, utilizing funding from the U.S. Department of Energy's Buildings Technologies Program, completed research to develop, validate, and commercialize a range of cost-effective, low-emissivity energy-control retrofit window films with significantly improved emissivity over current technology. These films, sold under the EnerLogic® trade name, offer the energy-saving properties of modern low-e windows, with several advantages over replacement windows, such as: lower initial installation cost, a significantly lower product carbon footprint, and an ability to provide a much faster return on investment. EnerLogic® window films also offer significantly greater energy savings than previously available with window films with similar visiblemore » light transmissions. EnerLogic® window films offer these energy-saving advantages over other window films due to its ability to offer both summer cooling and winter heating savings. Unlike most window films, that produce savings only during the cooling season, EnerLogic® window film is an all-season, low-emissivity (low-e) film that produces both cooling and heating season savings. This paper will present technical information on the development hurdles as well as details regarding the following claims being made about EnerLogic® window film, which can be found at www.EnerLogicfilm.com: 1. Other window film technologies save energy. EnerLogic® window film's patent-pending coating delivers excellent energy efficiency in every season, so no other film can match its annual dollar or energy consumption savings. 2. EnerLogic® window film is a low-cost, high-return technology that compares favorably to other popular energy-saving measures both in terms of energy efficiency and cost savings. In fact, EnerLogic® window film typically outperforms most of the alternatives in terms of simple payback. 3. EnerLogic® window film provides unparalleled glass insulating capabilities for window film products. With its patent-pending low-e technology, EnerLogic® window film has the best insulating performance of any film product available. The insulating power of EnerLogic® window film gives single-pane windows the annual insulating performance of double-pane windows - and gives double-pane windows the annual insulating performance of triple-pane windows.« less
Residential Building Energy Code Field Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. Bartlett, M. Halverson, V. Mendon, J. Hathaway, Y. Xie
This document presents a methodology for assessing baseline energy efficiency in new single-family residential buildings and quantifying related savings potential. The approach was developed by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) Building Energy Codes Program with the objective of assisting states as they assess energy efficiency in residential buildings and implementation of their building energy codes, as well as to target areas for improvement through energy codes and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data setmore » to represent baseline construction practices across U.S. states.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mims, Natalie; Schiller, Steven R.; Stuart, Elizabeth
In the last decade, a new policy area has emerged to boost energy efficiency in buildings that focuses on the simple action of measuring energy use as compared to buildings of similar type and size, and making that data publicly available. These efforts, referred to as benchmarking and transparency (B&T) policies, seek to unlock new energy efficiency opportunities in the country’s existing buildings by promoting data-driven decision-making and creating stronger market signals. This report focuses on the 24 state and local jurisdictions that (as of December 31, 2016) require owners of privately owned commercial buildings, multifamily buildings, or both tomore » comply with a B&T policy. The report provides a summary of U.S. B&T policy design and implementation characteristics, reports results and impacts for jurisdictions with B&T policies, and discusses opportunities for increasing the efficacy of B&T policies, as well as suggested areas for further research. Among the findings, all but one of the B&T policy evaluation studies reviewed indicate some reduction (from 1.6% to 14%) in energy use, energy costs, or energy intensity over the two- to four-year period of the analyses. More specifically, most of the studies reviewed indicate 3% to 8% reductions in gross energy consumption or energy use intensity over a two- to four-year period of B&T policy implementation. Two additional evaluation studies indicate that there is a causal relationship between B&T policies and energy savings or energy cost savings. These documented impacts should be reviewed with some caution. While consistently showing energy savings benefits associated with B&T policies, these savings estimates should be considered preliminary because of the limited period of analyses and inconsistencies in analysis methods for the various studies. A nationally standardized method for data collection, reporting, and evaluation of B&T policies—developed with an advisory group of state and local jurisdictions, energy efficiency and evaluation experts, building owner and real estate associations, and other stakeholders—could improve the consistency and quality of B&T impact studies, providing policymakers and others with a more complete understanding of the present and future impacts of these policies.« less
Monforti-Ferrario, Fabio; Kona, Albana; Peduzzi, Emanuela; Pernigotti, Denise; Pisoni, Enrico
2018-06-08
This study is a first attempt to evaluate how the major efforts made by several European cities in the frame of the Covenant of Mayors (CoM) initiative can impact the air pollution levels in the participating cities. CoM is by no mean one of the major cities initiatives aimed at mitigating climate change, supporting local authorities in the implementation of their climate action plans. Energy savings measures reported in the CoM cities' action plans have been analysed from the air quality perspective in order to find quantitative relations in the way local authorities deal with mitigation and how these practices are expected to have consequences on the air quality at urban level and finally positively impacting the citizens' health. In the paper, the air quality 2713 energy saving measures proposed by 146 cities located in 23 countries in the frame of the CoM are selected and their co-benefits for air quality and public health estimated by means of SHERPA, a fast modelling tool that mimics the behaviour of a full physically-based Chemical Transport Model. Besides evaluating the overall benefits of this subset of mitigation measures for the air quality, the study also investigates the relevance of some factors such as the implementation sector, the city size and the pollution levels in achieving the highest possible co-benefits. The results presented refer to the special field covered by the study, i.e. energy saving measures and are not automatically referable to other types of measures. Nevertheless, they clearly show how climate mitigation and air quality policies are deeply interconnected at the urban level. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Compressed Air System Optimization: Case Study Food Industry in Indonesia
NASA Astrophysics Data System (ADS)
Widayati, Endang; Nuzahar, Hasril
2016-01-01
Compressors and compressed air systems was one of the most important utilities in industries or factories. Approximately 10% of the cost of electricity in the industry was used to produce compressed air. Therefore the potential for energy savings in the compressors and compressed air systems had a big challenge. This field was conducted especially in Indonesia food industry or factory. Compressed air system optimization was a technique approach to determine the optimal conditions for the operation of compressors and compressed air systems that included evaluation of the energy needs, supply adjustment, eliminating or reconfiguring the use and operation of inefficient, changing and complementing some equipment and improving operating efficiencies. This technique gave the significant impact for energy saving and costs. The potential savings based on this study through measurement and optimization e.g. system that lowers the pressure of 7.5 barg to 6.8 barg would reduce energy consumption and running costs approximately 4.2%, switch off the compressor GA110 and GA75 was obtained annual savings of USD 52,947 ≈ 455 714 kWh, running GA75 light load or unloaded then obtained annual savings of USD 31,841≈ 270,685 kWh, install new compressor 2x132 kW and 1x 132 kW VSD obtained annual savings of USD 108,325≈ 928,500 kWh. Furthermore it was needed to conduct study of technical aspect of energy saving potential (Investment Grade Audit) and performed Cost Benefit Analysis. This study was one of best practice solutions how to save energy and improve energy performance in compressors and compressed air system.
Health, Energy Efficiency and Climate Change
Climate change is becoming a driving force for improving energy efficiency because saving energy can help reduce the greenhouse gas emissions that contribute to climate change. However, it is important to balance energy saving measures with ventilation...
Energy 101: Energy Efficient Commercial Buildings
None
2018-06-06
Learn how commercial buildings can incorporate whole-building design to save energy and money while enhancing performance and comfort. This video highlights several energy-saving features of the Research Support Facility at the Energy Department's National Renewable Energy Laboratory-a model for high-performance office building design.
Advanced Commercial Buildings Initiative Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, Sydney G.
The Southface Advanced Commercial Buildings Initiative has developed solutions to overcome market barriers to energy reductions in small commercial buildings by building on the success of four local and Southeast regional energy efficiency deployment programs. These programs address a variety of small commercial building types, efficiency levels, owners, facility manager skills and needs for financing. The deployment programs also reach critical private sector, utility, nonprofit and government submarkets, and have strong potential to be replicated at scale. During the grant period, 200 small commercial buildings participated in Southface-sponsored energy upgrade programs, saving 166,736,703 kBtu of source energy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This guide provides federal facility managers with an overview of the energy savings potential of wireless lighting occupancy sensors for various room types, cost considerations, key steps to successful installation of wireless sensors, pros and cons of various technology options, light source considerations, and codes and standards.
NASA Astrophysics Data System (ADS)
Orekhova, T. N.; Nosov, O. A.; Prokopenko, V. S.; Kachaev, A. E.
2018-03-01
The improvement of the design of the pneumatic mixers aimed at the possibility of obtaining homogeneous disperse systems, while the resource and energy saving issues play an important role in the conditions of enterprises that use this type of equipment in their technological chain, is described in the article.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Confer, L.; Kramer, K.L.
A condensing type heat exchanger operating at Henkel Corporation's plant in Kankakee, IL, has enabled the plant to save $400,000 in energy costs within the first 22 months of operation, recouping the initial capital investment for the unit within that time frame. The heat exchanger enables the plant to accomplish what historically was considered taboo - to cool boiler stack gas down to 130/sup 0/F, below the dew point, and thus recover both sensible and latent heat from the gas. Traditionally, moisture could not be squeezed out of stack gas below the recommended temperature of 250/sup 0/F because the stackmore » gas close to the heat exchanger tubes would approach the dew point, condense and attack metal surfaces. The condensing type heat exchanger can withstand corrosive conditions, however, because all wetted surfaces on the flue side of the shell and copper-nickel tube design are protected with an extruded Teflon fluorocarbon resin covering (not coating). The waste heat recovery system was installed over a two-month period in 1985. Performance has been above expectations with greater energy savings than originally projected. The amount of operator attention required is minimal.« less
Annual Energy Usage Reduction and Cost Savings of a School: End-Use Energy Analysis
Alghoul, M. A.; Bakhtyar, B.; Asim, Nilofar; Sopian, K.
2014-01-01
Buildings are among the largest consumers of energy. Part of the energy is wasted due to the habits of users and equipment conditions. A solution to this problem is efficient energy usage. To this end, an energy audit can be conducted to assess the energy efficiency. This study aims to analyze the energy usage of a primary school and identify the potential energy reductions and cost savings. A preliminary audit was conducted, and several energy conservation measures were proposed. The energy conservation measures, with reference to the MS1525:2007 standard, were modelled to identify the potential energy reduction and cost savings. It was found that the school's usage of electricity exceeded its need, incurring an excess expenditure of RM 2947.42. From the lighting system alone, it was found that there is a potential energy reduction of 5489.06 kWh, which gives a cost saving of RM 2282.52 via the improvement of lighting system design and its operating hours. Overall, it was found that there is a potential energy reduction and cost saving of 20.7% when the energy conservation measures are earnestly implemented. The previous energy intensity of the school was found to be 50.6 kWh/m2/year, but can theoretically be reduced to 40.19 kWh/mm2/year. PMID:25485294
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pless, S.; Torcellini, P.; Long, N.
2007-09-01
This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for K-12 School Buildings (K-12 AEDG), a design guidance document intended to provide recommendations for achieving 30% energy savings in K-12 Schools over levels contained in ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings. The 30% energy savings target is the first step toward achieving net-zero energy schools; schools that, on an annual basis, draw from outside sources less or equal energy than they generate on site from renewable energy sources.
Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2013-10-01
This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilation strategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7. Median energy use for the development is 11,000 kWh; annual energy costsmore » are $780, with a fair amount of variation dependent on size of home. Preliminary analysis of savings between Salishan 7 and previous phases (4 through 6) suggest savings of between 20 and 30 percent. A more comprehensive comparison between Salishan 7 and previous phases will take place in year two of this project.« less
Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, A.; Lubliner, M.; Howard, L.
2013-10-01
This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilationstrategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7. Median energy use for the development is 11,000 kWh; annual energy costs aremore » $780, with a fair amount of variation dependent on size of home. Preliminary analysis of savings betweenSalishan 7 and previous phases (4 through 6) suggest savings of between 20 and 30 percent. A more comprehensive comparison between Salishan 7 and previous phases will take place in year two of this project.« less
Green Energy in New Construction: Maximize Energy Savings and Minimize Cost
ERIC Educational Resources Information Center
Ventresca, Joseph
2010-01-01
People often use the term "green energy" to refer to alternative energy technologies. But green energy doesn't guarantee maximum energy savings at a minimum cost--a common misconception. For school business officials, green energy means getting the lowest energy bills for the lowest construction cost, which translates into maximizing green energy…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desroches, Louis-Benoit; Garbesi, Karina
It is well established that energy efficiency is most often the lowest cost approach to reducing national energy use and minimizing carbon emissions. National investments in energy efficiency to date have been highly cost-effective. The cumulative impacts (out to 2050) of residential energy efficiency standards are expected to have a benefit-to-cost ratio of 2.71:1. This project examined energy end-uses in the residential, commercial, and in some cases the industrial sectors. The scope is limited to appliances and equipment, and does not include building materials, building envelopes, and system designs. This scope is consistent with the scope of DOE's appliance standardsmore » program, although many products considered here are not currently subject to energy efficiency standards. How much energy could the United States save if the most efficient design options currently feasible were adopted universally? What design features could produce those savings? How would the savings from various technologies compare? With an eye toward identifying promising candidates and strategies for potential energy efficiency standards, the Max Tech and Beyond project aims to answer these questions. The analysis attempts to consolidate, in one document, the energy savings potential and design characteristics of best-on-market products, best-engineered products (i.e., hypothetical products produced using best-on-market components and technologies), and emerging technologies in research & development. As defined here, emerging technologies are fundamentally new and are as yet unproven in the market, although laboratory studies and/or emerging niche applications offer persuasive evidence of major energy-savings potential. The term 'max tech' is used to describe both best-engineered and emerging technologies (whichever appears to offer larger savings). Few best-on-market products currently qualify as max tech, since few apply all available best practices and components. The three primary analyses presented in this report are: Nevertheless, it is important to analyze best-on-market products, since data on truly max tech technologies are limited. (1) an analysis of the cross-cutting strategies most promising for reducing appliance and equipment energy use in the U.S.; (2) a macro-analysis of the U.S. energy-saving potential inherent in promising ultra-efficient appliance technologies; and (3) a product-level analysis of the energy-saving potential.« less
12 New England Organizations Honored for Outstanding Achievements in Energy Efficiency
EPA and the U.S. Department of Energy (DOE) are honoring 12 New England businesses and organizations for their commitment to saving energy, saving money, and protecting the environment through superior energy efficiency achievements.
Energy Savings Performance Contract Energy Sales Agreement Toolkit
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
FEMP developed the Energy Savings Performance Contracting Energy Sales Agreement (ESPC ESA) Toolkit to provide federal agency contracting officers and other acquisition team members with information that will facilitate the timely execution of ESPC ESA projects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blasnik, Michael; Dalhoff, Greg; Carroll, David
This report estimates energy savings, energy cost savings, and cost effectiveness attributable to weatherizing large multifamily buildings under the auspices of the Department of Energy's Weatherization Assistance Program during Program Year 2008.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blasnik, Michael; Dalhoff, Greg; Carroll, David
2014-09-01
This report estimates energy savings, energy cost savings, and cost effectiveness attributable to weatherizing small multifamily buildings under the auspices of the Department of Energy's Weatherization Assistance Program during Program Year 2008.
Vehicle lightweighting energy use impacts in U.S. light-duty vehicle fleet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Das, Sujit; Graziano, Diane; Upadhyayula, Venkata K. K.
In this article, we estimate the potential energy benefits of lightweighting the light-duty vehicle fleet from both vehicle manufacturing and use perspectives using plausible lightweight vehicle designs involving several alternative lightweight materials, low- and high-end estimates of vehicle manufacturing energy, conventional and alternative powertrains, and two different market penetration scenarios for alternative powertrain light-duty vehicles at the fleet level. Cumulative life cycle energy savings (through 2050) across the nine material scenarios based on the conventional powertrain in the U.S. vehicle fleet range from -29 to 94 billion GJ, with the greatest savings achieved by multi-material vehicles that select different lightweightmore » materials to meet specific design purposes. Lightweighting alternative-powertrain vehicles could produce significant energy savings in the U.S. vehicle fleet, although their improved powertrain efficiencies lessen the energy savings opportunities for lightweighting. A maximum level of cumulative energy savings of lightweighting the U.S. light-duty vehicle through 2050 is estimated to be 66.1billion GJ under the conventional-vehicle dominated business-as-usual penetration scenario.« less
Energy Efficient Operation of Ammonia Refrigeration Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohammed, Abdul Qayyum; Wenning, Thomas J; Sever, Franc
Ammonia refrigeration systems typically offer many energy efficiency opportunities because of their size and complexity. This paper develops a model for simulating single-stage ammonia refrigeration systems, describes common energy saving opportunities, and uses the model to quantify those opportunities. The simulation model uses data that are typically available during site visits to ammonia refrigeration plants and can be calibrated to actual consumption and performance data if available. Annual electricity consumption for a base-case ammonia refrigeration system is simulated. The model is then used to quantify energy savings for six specific energy efficiency opportunities; reduce refrigeration load, increase suction pressure, employmore » dual suction, decrease minimum head pressure set-point, increase evaporative condenser capacity, and reclaim heat. Methods and considerations for achieving each saving opportunity are discussed. The model captures synergistic effects that result when more than one component or parameter is changed. This methodology represents an effective method to model and quantify common energy saving opportunities in ammonia refrigeration systems. The results indicate the range of savings that might be expected from common energy efficiency opportunities.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mittal, Sparsh; Zhang, Zhao; Vetter, Jeffrey S
Recent trends of CMOS scaling and use of large last level caches (LLCs) have led to significant increase in the leakage energy consumption of LLCs and hence, managing their energy consumption has become extremely important in modern processor design. The conventional cache energy saving techniques require offline profiling or provide only coarse granularity of cache allocation. We present FlexiWay, a cache energy saving technique which uses dynamic cache reconfiguration. FlexiWay logically divides the cache sets into multiple (e.g. 16) modules and dynamically turns off suitable and possibly different number of cache ways in each module. FlexiWay has very small implementationmore » overhead and it provides fine-grain cache allocation even with caches of typical associativity, e.g. an 8-way cache. Microarchitectural simulations have been performed using an x86-64 simulator and workloads from SPEC2006 suite. Also, FlexiWay has been compared with two conventional energy saving techniques. The results show that FlexiWay provides largest energy saving and incurs only small loss in performance. For single, dual and quad core systems, the average energy saving using FlexiWay are 26.2%, 25.7% and 22.4%, respectively.« less
The Analysis for Energy Consumption of Marine Air Conditioning System Based on VAV and VWV
NASA Astrophysics Data System (ADS)
Xu, Sai Feng; Yang, Xing Lin; Le, Zou Ying
2018-06-01
For ocean-going vessels sailing in different areas on the sea, the change of external environment factors will cause frequent changes in load, traditional ship air-conditioning system is usually designed with a fixed cooling capacity, this design method causes serious waste of resources. A new type of sea-based air conditioning system is proposed in this paper, which uses the sea-based source heat pump system, combined with variable air volume, variable water technology. The multifunctional cabins' dynamic loads for a ship navigating in a typical Eurasian route were calculated based on Simulink. The model can predict changes in full voyage load. Based on the simulation model, the effects of variable air volume and variable water volume on the energy consumption of the air-conditioning system are analyzed. The results show that: When the VAV is coupled with the VWV, the energy saving rate is 23.2%. Therefore, the application of variable air volume and variable water technology to marine air conditioning systems can achieve economical and energy saving advantages.
Energy efficiency public service advertising campaign
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gibson-Grant, Amanda
The Advertising Council (“the Ad Council”) and The United States Department of Energy (DOE) created and launched a national public service advertising campaign designed to promote energy efficiency. The objective of the Energy Efficiency campaign was to redefine how consumers approach energy efficiency by showing that saving energy can save homeowners money.
VO2 thermochromic smart window for energy savings and generation
Zhou, Jiadong; Gao, Yanfeng; Zhang, Zongtao; Luo, Hongjie; Cao, Chuanxiang; Chen, Zhang; Dai, Lei; Liu, Xinling
2013-01-01
The ability to achieve energy saving in architectures and optimal solar energy utilisation affects the sustainable development of the human race. Traditional smart windows and solar cells cannot be combined into one device for energy saving and electricity generation. A VO2 film can respond to the environmental temperature to intelligently regulate infrared transmittance while maintaining visible transparency, and can be applied as a thermochromic smart window. Herein, we report for the first time a novel VO2-based smart window that partially utilises light scattering to solar cells around the glass panel for electricity generation. This smart window combines energy-saving and generation in one device, and offers potential to intelligently regulate and utilise solar radiation in an efficient manner. PMID:24157625
VO₂ thermochromic smart window for energy savings and generation.
Zhou, Jiadong; Gao, Yanfeng; Zhang, Zongtao; Luo, Hongjie; Cao, Chuanxiang; Chen, Zhang; Dai, Lei; Liu, Xinling
2013-10-24
The ability to achieve energy saving in architectures and optimal solar energy utilisation affects the sustainable development of the human race. Traditional smart windows and solar cells cannot be combined into one device for energy saving and electricity generation. A VO2 film can respond to the environmental temperature to intelligently regulate infrared transmittance while maintaining visible transparency, and can be applied as a thermochromic smart window. Herein, we report for the first time a novel VO2-based smart window that partially utilises light scattering to solar cells around the glass panel for electricity generation. This smart window combines energy-saving and generation in one device, and offers potential to intelligently regulate and utilise solar radiation in an efficient manner.
Energy Savings in Cellular Networks Based on Space-Time Structure of Traffic Loads
NASA Astrophysics Data System (ADS)
Sun, Jingbo; Wang, Yue; Yuan, Jian; Shan, Xiuming
Since most of energy consumed by the telecommunication infrastructure is due to the Base Transceiver Station (BTS), switching off BTSs when traffic load is low has been recognized as an effective way of saving energy. In this letter, an energy saving scheme is proposed to minimize the number of active BTSs based on the space-time structure of traffic loads as determined by principal component analysis. Compared to existing methods, our approach models traffic loads more accurately, and has a much smaller input size. As it is implemented in an off-line manner, our scheme also avoids excessive communications and computing overheads. Simulation results show that the proposed method has a comparable performance in energy savings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coleman, Philip; Earni, Shankar; Williams, Charles
2014-08-11
Claims that savings realization is greater in energy savings performance contracts (ESPCs) are rampant at least among energy service company representatives and other ESPC cheerleaders. But hard supporting evidence for these claims has been virtually non-existent. The Department of Energy's Federal Energy Management Program uses its Compliance Tracking System (CTS) database to document the performance of federal buildings and projects towards meeting various federal energy-saving goals. This paper focuses on preliminary analysis from CTS to understand and compare the performance of federal ESPCs with projects that have been implemented with more conventional government appropriations funding. The authors have found preliminarymore » evidence using CTS that shows markedly higher savings realization rates among ESPC projects than appropriations-funded ones. There are numerous caveats to the data comparison that clamor for further study, but the difference is still intriguing. If borne out, this finding will provide concrete support to the idea that ESPCs guarantees and measurement and verification, long touted by energy service companies (ESCOs) as offering savings assurance, may truly yield substantial benefits. If ESPCs actually do perform better (i.e., have higher realization rates and savings persistence) than conventional bid-to-spec projects, the perceived premium for conducting them may look like a very good deal after all.« less
Consumer Products Advertised to Save Energy--Let the Buyer Beware.
1981-07-24
AD-AL06 653 GENERAL ACCOUNTING OFFICE WASHINGTON DC HUMAN RESOUR--ETC F/G 5/3 CONSUMER PRODUCTS ADVERTISED TO SAVE ENERGY--LET THE BUYER BEWA-ETC...COMPTROLLER GENERAL’S CONSUMER PRODUCTS ADVERTISED REPORT TO THE CONGRESS TO SAVE ENERGY- - LET THE BUYER BEWARE D IG E ST In efforts to reduce energy costs...Federal and State efforts to protect consumers from inaccurate or misleading claims. GAO noted hundreds of advertisements having ques- tionable
Application of automated measurement and verification to utility energy efficiency program data
Granderson, Jessica; Touzani, Samir; Fernandes, Samuel; ...
2017-02-17
Trustworthy savings calculations are critical to convincing regulators of both the cost-effectiveness of energy efficiency program investments and their ability to defer supply-side capital investments. Today’s methods for measurement and verification (M&V) of energy savings constitute a significant portion of the total costs of energy efficiency programs. They also require time-consuming data acquisition. A spectrum of savings calculation approaches is used, with some relying more heavily on measured data and others relying more heavily on estimated, modeled, or stipulated data. The increasing availability of “smart” meters and devices that report near-real time data, combined with new analytical approaches to quantifymore » savings, offers the potential to conduct M&V more quickly and at lower cost, with comparable or improved accuracy. Commercial energy management and information systems (EMIS) technologies are beginning to offer these ‘M&V 2.0’ capabilities, and program administrators want to understand how they might assist programs in quickly and accurately measuring energy savings. This paper presents the results of recent testing of the ability to use automation to streamline the M&V process. In this paper, we apply an automated whole-building M&V tool to historic data sets from energy efficiency programs to begin to explore the accuracy, cost, and time trade-offs between more traditional M&V, and these emerging streamlined methods that use high-resolution energy data and automated computational intelligence. For the data sets studied we evaluate the fraction of buildings that are well suited to automated baseline characterization, the uncertainty in gross savings that is due to M&V 2.0 tools’ model error, and indications of labor time savings, and how the automated savings results compare to prior, traditionally determined savings results. The results show that 70% of the buildings were well suited to the automated approach. In a majority of the cases (80%) savings and uncertainties for each individual building were quantified to levels above the criteria in ASHRAE Guideline 14. In addition the findings suggest that M&V 2.0 methods may also offer time-savings relative to traditional approaches. Lastly, we discuss the implications of these findings relative to the potential evolution of M&V, and pilots currently being launched to test how M&V automation can be integrated into ratepayer-funded programs and professional implementation and evaluation practice.« less
Application of automated measurement and verification to utility energy efficiency program data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Granderson, Jessica; Touzani, Samir; Fernandes, Samuel
Trustworthy savings calculations are critical to convincing regulators of both the cost-effectiveness of energy efficiency program investments and their ability to defer supply-side capital investments. Today’s methods for measurement and verification (M&V) of energy savings constitute a significant portion of the total costs of energy efficiency programs. They also require time-consuming data acquisition. A spectrum of savings calculation approaches is used, with some relying more heavily on measured data and others relying more heavily on estimated, modeled, or stipulated data. The increasing availability of “smart” meters and devices that report near-real time data, combined with new analytical approaches to quantifymore » savings, offers the potential to conduct M&V more quickly and at lower cost, with comparable or improved accuracy. Commercial energy management and information systems (EMIS) technologies are beginning to offer these ‘M&V 2.0’ capabilities, and program administrators want to understand how they might assist programs in quickly and accurately measuring energy savings. This paper presents the results of recent testing of the ability to use automation to streamline the M&V process. In this paper, we apply an automated whole-building M&V tool to historic data sets from energy efficiency programs to begin to explore the accuracy, cost, and time trade-offs between more traditional M&V, and these emerging streamlined methods that use high-resolution energy data and automated computational intelligence. For the data sets studied we evaluate the fraction of buildings that are well suited to automated baseline characterization, the uncertainty in gross savings that is due to M&V 2.0 tools’ model error, and indications of labor time savings, and how the automated savings results compare to prior, traditionally determined savings results. The results show that 70% of the buildings were well suited to the automated approach. In a majority of the cases (80%) savings and uncertainties for each individual building were quantified to levels above the criteria in ASHRAE Guideline 14. In addition the findings suggest that M&V 2.0 methods may also offer time-savings relative to traditional approaches. Lastly, we discuss the implications of these findings relative to the potential evolution of M&V, and pilots currently being launched to test how M&V automation can be integrated into ratepayer-funded programs and professional implementation and evaluation practice.« less
The High Cost of Saving Energy Dollars.
ERIC Educational Resources Information Center
Rose, Patricia
1985-01-01
In alternative financing a private company provides the capital and expertise for improving school energy efficiency. Savings are split between the school system and the company. Options for municipal leasing, cost sharing, and shared savings are explained along with financial, procedural, and legal considerations. (MLF)
Creative Energy Management Can Save Money.
ERIC Educational Resources Information Center
Rose, Patricia
1984-01-01
Schools can launch energy conservation programs with simple money-saving measures like improving boiler maintenance, recalibrating utility meters, and obtaining preferred utility rates. Becoming more assertive in the marketplace and using "creative financing" when needed, they can then reinvest their savings in more extensive projects. (MCG)
Energy-Saving Opportunities for Manufacturing Companies, (English/Russian Fact Sheet) (Revised)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This English/Russian brochure describes the Industrial Technologies Program Save Energy Now model and provides information on tools and resources to help manufacturing facilities reduce industrial energy intensity.
Energy-Saving Opportunities for Manufacturing Companies, International Fact Sheet (Spanish)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This English/Spanish fact sheet describes the Industrial Technologies Program Save Energy Now model and provides information on tools and resources to help manufacturing facilities reduce industrial energy intensity.
Energy saving effects of wireless sensor networks: a case study of convenience stores in Taiwan.
Chen, Chih-Sheng; Lee, Da-Sheng
2011-01-01
Wireless sensor network (WSN) technology has been successfully applied to energy saving applications in many places, and plays a significant role in achieving power conservation. However, previous studies do not discuss WSN costs and cost-recovery. The application of WSNs is currently limited to research and laboratory experiments, and not mass industrial production, largely because business owners are unfamiliar with the possible favorable return and cost-recovery on WSN investments. Therefore, this paper focuses on the cost-recovery of WSNs and how to reduce air conditioning energy consumption in convenience stores. The WSN used in this study provides feedback to the gateway and adopts the predicted mean vote (PMV) and computational fluid dynamics (CFD) methods to allow customers to shop in a comfortable yet energy-saving environment. Four convenience stores in Taipei have used the proposed WSN since 2008. In 2008, the experiment was initially designed to optimize air-conditioning for energy saving, but additions to the set-up continued beyond 2008, adding the thermal comfort and crowds peak, off-peak features in 2009 to achieve human-friendly energy savings. Comparison with 2007 data, under the same comfort conditions, shows that the power savings increased by 40% (2008) and 53% (2009), respectively. The cost of the WSN equipment was 500 US dollars. Experimental results, including three years of analysis and calculations, show that the marginal energy conservation benefit of the four convenience stores achieved energy savings of up to 53%, recovering all costs in approximately 5 months. The convenience store group participating in this study was satisfied with the efficiency of energy conservation because of the short cost-recovery period.
Energy Saving Effects of Wireless Sensor Networks: A Case Study of Convenience Stores in Taiwan
Chen, Chih-Sheng; Lee, Da-Sheng
2011-01-01
Wireless sensor network (WSN) technology has been successfully applied to energy saving applications in many places, and plays a significant role in achieving power conservation. However, previous studies do not discuss WSN costs and cost-recovery. The application of WSNs is currently limited to research and laboratory experiments, and not mass industrial production, largely because business owners are unfamiliar with the possible favorable return and cost-recovery on WSN investments. Therefore, this paper focuses on the cost-recovery of WSNs and how to reduce air conditioning energy consumption in convenience stores. The WSN used in this study provides feedback to the gateway and adopts the predicted mean vote (PMV) and computational fluid dynamics (CFD) methods to allow customers to shop in a comfortable yet energy-saving environment. Four convenience stores in Taipei have used the proposed WSN since 2008. In 2008, the experiment was initially designed to optimize air-conditioning for energy saving, but additions to the set-up continued beyond 2008, adding the thermal comfort and crowds peak, off-peak features in 2009 to achieve human-friendly energy savings. Comparison with 2007 data, under the same comfort conditions, shows that the power savings increased by 40% (2008) and 53% (2009), respectively. The cost of the WSN equipment was 500 US dollars. Experimental results, including three years of analysis and calculations, show that the marginal energy conservation benefit of the four convenience stores achieved energy savings of up to 53%, recovering all costs in approximately 5 months. The convenience store group participating in this study was satisfied with the efficiency of energy conservation because of the short cost-recovery period. PMID:22319396
ERIC Educational Resources Information Center
BRI Systems, Inc., Phoenix, AZ.
This publication is a guide for school districts to reduce pupil transportation costs and save energy. The information presented is based upon: (1) energy saving programs implemented by school districts; (2) government and industry research efforts in fuel economy; (3) the successful experiences of commercial trucking fleets to save fuel; and (4)…
ERIC Educational Resources Information Center
Lee, Lung-Sheng; Lin, Kuen-Yi; Guu, Yunn-Horng; Chang, Liang-Te; Lai, Chih-Chien
2013-01-01
Energy saving and carbon-emissions reduction (ESCER) are widely regarded as important issues for progress towards ensuring sustainable forms of economic development. This Taiwanese study focuses on the effects of a series of educational activities about ESCER on students' knowledge, attitudes and behavior. Sixty fifth-grade students from two…
Impacts of Model Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Athalye, Rahul A.; Sivaraman, Deepak; Elliott, Douglas B.
The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program; this study looked more broadly at overall code impacts. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions atmore » the state level and at aggregated levels. This analysis does not represent all potential savings from energy codes in the U.S. because it excludes several states which have codes which are fundamentally different from the national model energy codes or which do not have state-wide codes. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when buildings comply with the code. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. Delayed adoption of a model code and incomplete compliance with the code’s requirements erode potential savings. The contributions of all three phases are crucial to the overall impact of codes, and are considered in this assessment.« less
Maximizing Residential Energy Savings: Net Zero Energy House (ZEH) Technology Pathways
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, R.; Roberts, D.
To meet current U.S. Department of Energy zero-energy home performance goals, new technologies and solutions must increase whole-house efficiency savings by an additional 40% relative to those provided by best available components and systems.
Frequently Asked Questions about Energy Savings Plus Health
The Energy Savings Plus Health Guide equips school districts to integrate indoor air quality protections into school energy efficiency retrofits and other building upgrade projects. This page asks and answers Frequently-Asked Questions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This English/Portuguese brochure describes the Industrial Technologies Program Save Energy Now model and provides information on tools and resources to help manufacturing facilities reduce industrial energy intensity.
After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-load Equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.
2004-01-22
This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of ''miscellaneous'' plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers.more » This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from twelve commercial buildings in California, Georgia, and Pennsylvania: two health care buildings, two large offices (> 500 employees each), three medium offices (50-500 employees), four education buildings, and one ''small office'' that is actually an aggregate of five small businesses. Two buildings are in the San Francisco Bay area of California, five are in Pittsburgh, Pennsylvania, and five are in Atlanta, Georgia.« less
City-scale analysis of water-related energy identifies more cost-effective solutions.
Lam, Ka Leung; Kenway, Steven J; Lant, Paul A
2017-02-01
Energy and greenhouse gas management in urban water systems typically focus on optimising within the direct system boundary of water utilities that covers the centralised water supply and wastewater treatment systems, despite a greater energy influence by the water end use. This work develops a cost curve of water-related energy management options from a city perspective for a hypothetical Australian city. It is compared with that from the water utility perspective. The curves are based on 18 water-related energy management options that have been implemented or evaluated in Australia. In the studied scenario, the cost-effective energy saving potential from a city perspective (292 GWh/year) is far more significant than that from a utility perspective (65 GWh/year). In some cases, for similar capital cost, if regional water planners invested in end use options instead of utility options, a greater energy saving potential at a greater cost-effectiveness could be achieved in urban water systems. For example, upgrading a wastewater treatment plant for biogas recovery at a capital cost of $27.2 million would save 31 GWh/year with a marginal cost saving of $63/MWh, while solar hot water system rebates at a cost of $28.6 million would save 67 GWh/year with a marginal cost saving of $111/MWh. Options related to hot water use such as water-efficient shower heads, water-efficient clothes washers and solar hot water system rebates are among the most cost-effective city-scale opportunities. This study demonstrates the use of cost curves to compare both utility and end use options in a consistent framework. It also illustrates that focusing solely on managing the energy use within the utility would miss substantial non-utility water-related energy saving opportunities. There is a need to broaden the conventional scope of cost curve analysis to include water-related energy and greenhouse gas at the water end use, and to value their management from a city perspective. This would create opportunities where the same capital investment could achieve far greater energy savings and greenhouse gas emissions abatement. Copyright © 2016 Elsevier Ltd. All rights reserved.
Monitoring and Characterization of Miscellaneous Electrical Loads in a Large Retail Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gentile-Polese, L.; Frank, S.; Sheppy, M.
2014-02-01
Buildings account for 40% of primary energy consumption in the United States (residential 22%; commercial 18%). Most (70% residential and 79% commercial) is used as electricity. Thus, almost 30% of U.S. primary energy is used to provide electricity to buildings. Plug loads play an increasingly critical role in reducing energy use in new buildings (because of their increased efficiency requirements), and in existing buildings (as a significant energy savings opportunity). If all installed commercial building miscellaneous electrical loads (CMELs) were replaced with energy-efficient equipment, a potential annual energy saving of 175 TWh, or 35% of the 504 TWh annual energymore » use devoted to MELs, could be achieved. This energy saving is equivalent to the annual energy production of 14 average-sized nuclear power plants. To meet DOE's long-term goals of reducing commercial building energy use and carbon emissions, the energy efficiency community must better understand the components and drivers of CMEL energy use, and develop effective reduction strategies. These goals can be facilitated through improved data collection and monitoring methodologies, and evaluation of CMELs energy-saving techniques.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucas, Robert G.; Taylor, Zachary T.; Mendon, Vrushali V.
2012-07-03
The 2012 International Energy Conservation Code (IECC) yields positive benefits for Ohio homeowners. Moving to the 2012 IECC from the 2009 IECC is cost-effective over a 30-year life cycle. On average, Ohio homeowners will save $5,151 with the 2012 IECC. Each year, the reduction to energy bills will significantly exceed increased mortgage costs. After accounting for up-front costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $330 for the 2012 IECC.
Characteristics of MSW and heat energy recovery between residential and commercial areas in Seoul.
Yi, Sora; Yoo, Kee-Young; Hanaki, Keisuke
2011-03-01
This paper analyzes the amount and characteristics of municipal solid waste (MSW) according to the inhabitant density of population and the business concentration in 25 districts in Seoul. Further, the heat energy recovery and avoided CO(2) emissions of four incineration plants located in residential and commercial areas in Seoul are examined. The amount of residential waste per capita tended to increase as the density of inhabitants decreased. The amount of commercial waste per capita tended to increase as the business concentration increased. The examination of the heat energy recovery characteristics indicated that the four incineration plants produced heat energy that depended on residential or commercial areas based on population and business. The most important result regarding avoided CO(2) emissions was that commercial areas with many office-type businesses had the most effective CO(2) emission savings by combusting 1 kg of waste. Assuming the full-scale operation of the four incineration plants, the amount of saved CO(2) emissions per year was 444 Gg CO(2) and 57,006 households in Seoul can be provided with heat energy equivalent to 542,711 Nm(3) of LNG. Copyright © 2010 Elsevier Ltd. All rights reserved.
Compressive behavior of energy-saving fired facing brick composite wall
NASA Astrophysics Data System (ADS)
Guo, Kai; Wu, Cai
2018-03-01
The energy-saving fired facing brick composite wall has a broad development prospects due to its merits of thermal insulation, energy conservation, beautiful, and natural. The construction and characteristics of this wall are introduced and analyzed in this paper. Experimental studies of samples are also conducted to investigate its compressive performance. The results show that the energy-saving fired facing brick composite wall has high compressive capacity. It has considerable application prospect, the study in this paper provides foundation to further studies.
10 CFR 436.21 - Savings-to-investment ratio.
Code of Federal Regulations, 2013 CFR
2013-01-01
... conservation measure. The numerator of the ratio is the present value of net savings in energy or water and non... replacement costs less salvage value attributable to the proposed energy or water conservation measure. [61 FR... DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Methodology and...
10 CFR 436.21 - Savings-to-investment ratio.
Code of Federal Regulations, 2012 CFR
2012-01-01
... conservation measure. The numerator of the ratio is the present value of net savings in energy or water and non... replacement costs less salvage value attributable to the proposed energy or water conservation measure. [61 FR... DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Methodology and...
10 CFR 436.21 - Savings-to-investment ratio.
Code of Federal Regulations, 2014 CFR
2014-01-01
... conservation measure. The numerator of the ratio is the present value of net savings in energy or water and non... replacement costs less salvage value attributable to the proposed energy or water conservation measure. [61 FR... DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Methodology and...
Saving Schoolhouse Energy. Final Report.
ERIC Educational Resources Information Center
Rudy, John; And Others
The objective of the Saving Schoolhouse Energy Program was to generate information that school administrators and federal energy/education decision makers could use to identify ways of implementing specific, economical remedies to reduce energy waste in schools. This program was designed to have five phases: (1) Conduct an energy audit of ten…
Rightsizing HVAC Systems to Reduce Capital Costs and Save Energy
ERIC Educational Resources Information Center
Sebesta, James
2010-01-01
Nearly every institution is faced with the situation of having to reduce the cost of a construction project from time to time through a process generally referred to as "value engineering." Just the mention of those words, however, gives rise to all types of connotations, thoughts, and memories (usually negative) for those in the…
Strategy on energy saving reconstruction of distribution networks based on life cycle cost
NASA Astrophysics Data System (ADS)
Chen, Xiaofei; Qiu, Zejing; Xu, Zhaoyang; Xiao, Chupeng
2017-08-01
Because the actual distribution network reconstruction project funds are often limited, the cost-benefit model and the decision-making method are crucial for distribution network energy saving reconstruction project. From the perspective of life cycle cost (LCC), firstly the research life cycle is determined for the energy saving reconstruction of distribution networks with multi-devices. Then, a new life cycle cost-benefit model for energy-saving reconstruction of distribution network is developed, in which the modification schemes include distribution transformers replacement, lines replacement and reactive power compensation. In the operation loss cost and maintenance cost area, the operation cost model considering the influence of load season characteristics and the maintenance cost segmental model of transformers are proposed. Finally, aiming at the highest energy saving profit per LCC, a decision-making method is developed while considering financial and technical constraints as well. The model and method are applied to a real distribution network reconstruction, and the results prove that the model and method are effective.
SBIR Phase II Final Report - Multi-Protocol Energy Management Gateway for Home-Area Networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanna, Jason
Significant amounts of electricity, natural gas, and heating oil are wasted by homeowners due to inefficient operation and inadequate maintenance of heating, ventilation, and air conditioning (HVAC) equipment. Coincident’s work under this award reduces energy waste, saves consumers money, and reduces carbon emissions. It does so in three ways: First, Coincident’s approach replaces the traditional thermostat with a wireless network of sensors and controllers that measure temperature, humidity and occupancy in multiple rooms in the house. The “Internet of Things” is a technology trend holding the promise of ubiquitous inexpensive sensors. The reality, however, is that energy and HVAC monitoringmore » and management is a patchwork of incompatible protocols and expensive proprietary technologies. Coincident’s multi-protocol architecture, developed in part under this award tackles this problem and brings low cost interoperable sensor and control devices to market. Second, the Coincident system eliminates hard-to-program and rigid thermostat schedules and instead provides automatic operation of heating and cooling by combining individual temperature and comfort preferences with energy-saving targets, real-time utility use information, weather data, and room utilization patterns. Energy efficiency technology must be appealing to consumers otherwise it will not be used. The Coincident user interface has engaging features such as remote control from any smart phone or web browser and per-room performance breakdowns. Expected energy savings resulting from more efficient operation of heating and air conditioning equipment are in the range of 10-20%. Third, the Coincident system provides heating and air-conditioning contractors with fine-grained performance data for every residence they support (subject to customer privacy controls). This data is integrated from diverse networks within the residence and includes HVAC performance and fuel use data. This information allows the partner to validate energy savings and identify potential system faults (whether from installation problems or maintenance issues). When combined with professional installation as part of high-efficiency HVAC upgrade, energy savings levels of 20-30% can be achieved. Economic feasibility of energy efficiency technology is one of the key challenges addressed in this award. The Coincident system is engineered to be delivered at a disruptive price point, making the system financially feasible for new and retrofit homes of all types and sizes. The Coincident system is intended to be sold through the HVAC professional—the industry most capable of improving HVAC efficiency. Providing HVAC contractors with detailed home performance data motivates them to sell the product, provides them with maintenance and upgrade revenue opportunities, and therefore delivers customer savings and environmental benefits. Having demonstrated technical and financial feasibility, Coincident has won additional grants and awards, participated in pilot projects, started partnership discussions with several HVAC equipment vendors, and has lined up several large channel partners ready to participate in large pilot rollouts.« less
Climate Change, Indoor Environment and Health
Climate change is becoming a driving force for improving energy efficiency because saving energy can help reduce the greenhouse gas emissions that contribute to climate change. However, it is important to balance energy saving measures with ventilation...
NASA Astrophysics Data System (ADS)
Xu, Xiaoqi
Reducing the energy consumed in the built environment is a key objective in many sustainability initiatives. Existing energy saving methods have consisted of physical interventions to buildings and/or behavioral modifications of occupants. However, such methods may not only suffer from their own disadvantages, e.g. high cost and transient effect, but also lose aggregate energy saving potential due to the oftentimes-associated single-building-focused view and an isolated examination of occupant behaviors. This dissertation attempts to overcome the limitations of traditional energy saving research and practical approaches, and enhance residential building energy efficiency and sustainability by proposing innovative energy strategies from a holistic perspective of the aggregate human-environment systems. This holistic perspective features: (1) viewing buildings as mutual influences in the built environment, (2) leveraging both the individual and contextualized social aspects of occupant behaviors, and (3) incorporating interactions between the built environment and human behaviors. First, I integrate three interlinked components: buildings, residents, and the surrounding neighborhood, and quantify the potential energy savings to be gained from renovating buildings at the inter-building level and leveraging neighborhood-contextualized occupant social networks. Following the confirmation of both the inter-building effect among buildings and occupants' interpersonal influence on energy conservation, I extend the research further by examining the synergy that may exist at the intersection between these "engineered" building networks and "social" peer networks, focusing specifically on the additional energy saving potential that could result from interactions between the two components. Finally, I seek to reach an alignment of the human and building environment subsystems by matching the thermostat preferences of each household with the thermal conditions within their apartment, and develop the Energy Saving Alignment Strategy to be considered in public housing assignment policy. This strategy and the inter-building level energy management strategies developed in my preceding research possess large-scale cost-effectiveness and may engender long-lasting influence compared with existing energy saving approaches. Building from the holistic framework of coupled human-environment systems, the findings of this research will advance knowledge of energy efficiency in the built environment and lead to the development of novel strategies to conserve energy in residential buildings.
Need for Systematic Retrofit Analysis in Multifamily Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malhotra, Mini; Im, Piljae
2014-01-01
Multifamily housing offers high potential for energy savings through retrofits. A comprehensive energy audit with systematic evaluation of alternative energy measures is one of the key steps to realizing the full energy savings potential. However, this potential often remains unrealized when the selection of measures is (1) based on a one-size-fits-all approach originating from accustomed practices, (2) intended merely to meet code-compliance requirements, and/or (3) influenced by owner renter split incentive. In such cases, the benefits of comprehensive energy auditing are disregarded in view of the apparent difficulty in diagnosing multifamily buildings, evaluating alternative measures, and installing customized sets ofmore » measures. This paper highlights some of the barriers encountered in a multifamily housing retrofit project in Georgia and demonstrates the merits of systematic retrofit analysis by identifying opportunities for higher energy savings and improved comfort and indoor air quality that were missed in this project. The study uses a whole-building energy analysis conducted for a 10-unit, low-rise, multifamily building of a 110-unit apartment complex. The analysis projected a 24% energy savings from the measures installed in the building with a payback period of 10 years. Further analysis with a systematic evaluation of alternative measures showed that without compromising on the objectives of durability, livability, and appearance of the building, energy savings of up to 34% were achievable with a payback period of 7 years. The paper concludes by outlining recommendations that may benefit future retrofit projects by improving the audit process, streamlining tasks, and achieving higher energy savings.« less
Energy Extra: Energy Savings vs. Comfort - and the Effect of Humidity.
ERIC Educational Resources Information Center
CEFP Journal, 1979
1979-01-01
Proper humidity will, in a large number of cases, save money for the user. This saving could show up directly because of reduced infiltration and lower thermostat settings. It could show up indirectly in reduced costs for maintenance and preservation and in increased productivity and decreased absenteeism. (Author)
The Three R's of Utility Savings: Rate Reduction, Rebates and Retrofit.
ERIC Educational Resources Information Center
Petiunas, Raymond V.
1993-01-01
An effective way to increase electricity energy savings for school districts is to integrate rate case participation (rate reduction) with conservation and load-management efforts (rebates) and retrofit operations, to obtain a total energy cost reduction package. Describes how a Pennsylvania consortium of school districts saved its member…
How to Save Money by Saving Energy.
ERIC Educational Resources Information Center
Department of Energy, Washington, DC.
This pamphlet presents energy conservation tips to help consumers save money. Conservation measures suggested here cover topics such as: (1) insulation; (2) space heating and cooling; (3) hot water heating; (4) cooking; (5) laundry; (6) lighting; (7) electrical appliances; (8) buying or building a home; and (9) buying, maintaining and driving a…
A Save-Energy, Save-Money Program That Pays Off
ERIC Educational Resources Information Center
Embersits, John F.
1976-01-01
Suggested guidelines for energy saving on campus include a 3-phase plan: (1) Quick Fix--effective management of what you already have; (2) Refitting--modification of existing systems and installation of simple controls; (3) Systems Convert--installation of computerized controls, waste-heat recovery, solid-waste recovery utilization and other…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucas, Robert G.; Taylor, Zachary T.; Mendon, Vrushali V.
2012-06-15
The 2012 International Energy Conservation Code (IECC) yields positive benefits for Iowa homeowners. Moving to the 2012 IECC from the 2009 IECC is cost effective over a 30-year life cycle. On average, Iowa homeowners will save $7,573 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $454 for the 2012 IECC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucas, Robert G.; Taylor, Zachary T.; Mendon, Vrushali V.
2012-06-15
The 2012 International Energy Conservation Code (IECC) yields positive benefits for Texas homeowners. Moving to the 2012 IECC from the 2009 IECC is cost effective over a 30-year life cycle. On average, Texas homeowners will save $3,456 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for the 2012 IECC. Average annual energy savings are $259 for the 2012 IECC.
Han, Jeongyun; Lee, Eunjung; Cho, Hyunghun; Yoon, Yoonjin; Lee, Hyoseop; Rhee, Wonjong
2018-05-17
In this paper, we provide findings from an energy saving experiment in a university building, where an IoT platform with 1 Hz sampling sensors was deployed to collect electric power consumption data. The experiment was a reward setup with daily feedback delivered by an energy delegate for one week, and energy saving of 25.4% was achieved during the experiment. Post-experiment sustainability, defined as 10% or more of energy saving, was also accomplished for 44 days without any further intervention efforts. The saving was possible mainly because of the data-driven intervention designs with high-resolution data in terms of sampling frequency and number of sensors, and the high-resolution data turned out to be pivotal for an effective waste behavior investigation. While the quantitative result was encouraging, we also noticed many uncontrollable factors, such as exams, papers due, office allocation shuffling, graduation, and new-comers, that affected the result in the campus environment. To confirm that the quantitative result was due to behavior changes, rather than uncontrollable factors, we developed several data-driven behavior detection measures. With these measures, it was possible to analyze behavioral changes, as opposed to simply analyzing quantitative fluctuations. Overall, we conclude that the space-time resolution of data can be crucial for energy saving, and potentially for many other data-driven energy applications.
Remote multi-function fire alarm system based on internet of things
NASA Astrophysics Data System (ADS)
Wang, Lihui; Zhao, Shuai; Huang, Jianqing; Ji, Jianyu
2018-05-01
This project uses MCU STC15W408AS (stable, energy saving, high speed), temperature sensor DS18B20 (cheap, high efficiency, stable), MQ2 resistance type semiconductor smog sensor (high stability, fast response and economy) and NRF24L01 wireless transmitting and receiving module (energy saving, small volume, reliable) as the main body to achieve concentration temperature data presentation, intelligent voice alarming and short distance wireless transmission. The whole system is safe, reliable, cheap, quick reaction and good performance. This project uses the MCU STM32F103RCT6 as the main control chip, and use WIFI module ESP8266, wireless module NRF24L01 to make the gateway. Users can remotely check and control the related devices in real-time on smartphones or computers. We can also realize the functions of intelligent fire monitoring, remote fire extinguishing, cloud data storage through the third party server Big IOT.
Overview of waste heat utilization systems
NASA Technical Reports Server (NTRS)
Bailey, M. M.
1984-01-01
The heavy truck diesel engine rejects a significant fraction of its fuel energy in the form of waste heat. Historically, the Department of Energy has supported technology efforts for utilization of the diesel exhaust heat. Specifically, the Turbocompound and the Organic Rankine Cycle System (ORCS) have demonstrated that meaningful improvements in highway fuel economy can be realized through waste heat utilization. For heat recovery from the high temperature exhaust of future adiabatic diesel engines, the DOE/NASA are investigating a variety of alternatives based on the Rankine, Brayton, and Stirling power cycles. Initial screening results indicate that systems of this type offer a fuel savings advantage over the turbocompound system. Capital and maintenance cost projections, however, indicate that the alternative power cycles are not competitive on an economic payback basis. Plans call for continued analysis in an attempt to identify a cost effective configuration with adequate fuel savings potential.
Experimental research on the application of HTAC in small-size heating furnace
NASA Astrophysics Data System (ADS)
Zhou, Yu; Qin, Chaokui; Yang, Jun; Chen, Zhiguang
2018-03-01
High temperature air combustion (HTAC) technology, which is also known as regenerative combustion technology, has realized energy saving, CO2 and NOx emissions reduction and low-noise combustion. It has been widely applied in various types of heating furnace and has achieved good energy-saving effect. However, there is little application of this technology in small-size furnace. In this paper, a small-size regenerative heating furnace was built in the laboratory and experiments were carried out on it. The result shows that, if the transport frequency was set to a group per min, the center temperature of processed workpiece at the rated conditions (i.e. burner power is 300 kW and switching time is 60s) reached 1133°C. And the efficiency of the heating furnace was 36.8%. Then the derived comprehensive heat transfer coefficient was 168 W/(m2˙°C).
Assessment of Energy Efficiency Improvement in the United States Petroleum Refining Industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrow, William R.; Marano, John; Sathaye, Jayant
2013-02-01
Adoption of efficient process technologies is an important approach to reducing CO 2 emissions, in particular those associated with combustion. In many cases, implementing energy efficiency measures is among the most cost-effective approaches that any refiner can take, improving productivity while reducing emissions. Therefore, careful analysis of the options and costs associated with efficiency measures is required to establish sound carbon policies addressing global climate change, and is the primary focus of LBNL’s current petroleum refining sector analysis for the U.S. Environmental Protection Agency. The analysis is aimed at identifying energy efficiency-related measures and developing energy abatement supply curves andmore » CO 2 emissions reduction potential for the U.S. refining industry. A refinery model has been developed for this purpose that is a notional aggregation of the U.S. petroleum refining sector. It consists of twelve processing units and account s for the additional energy requirements from steam generation, hydrogen production and water utilities required by each of the twelve processing units. The model is carbon and energy balanced such that crud e oil inputs and major refinery sector outputs (fuels) are benchmarked to 2010 data. Estimates of the current penetration for the identified energy efficiency measures benchmark the energy requirements to those reported in U.S. DOE 2010 data. The remaining energy efficiency potential for each of the measures is estimated and compared to U.S. DOE fuel prices resulting in estimates of cost- effective energy efficiency opportunities for each of the twelve major processes. A combined cost of conserved energy supply curve is also presented along with the CO 2 emissions abatement opportunities that exist in the U.S. petroleum refinery sector. Roughly 1,200 PJ per year of primary fuels savings and close to 500 GWh per y ear of electricity savings are potentially cost-effective given U.S. DOE fuel price forecasts. This represents roughly 70 million metric tonnes of CO 2 emission reductions assuming 2010 emissions factor for grid electricity. Energy efficiency measures resulting in an additional 400 PJ per year of primary fuels savings and close to 1,700 GWh per year of electricity savings, and an associated 24 million metric tonnes of CO 2 emission reductions are not cost-effective given the same assumption with respect to fuel prices and electricity emissions factors. Compared to the modeled energy requirements for the U.S. petroleum refining sector, the cost effective potential represents a 40% reduction in fuel consumption and a 2% reduction in electricity consumption. The non-cost-effective potential represents an additional 13% reduction in fuel consumption and an additional 7% reduction in electricity consumption. The relative energy reduction potentials are mu ch higher for fuel consumption than electricity consumption largely in part because fuel is the primary energy consumption type in the refineries. Moreover, many cost effective fuel savings measures would increase electricity consumption. The model also has the potential to be used to examine the costs and benefits of the other CO 2 mitigation options, such as combined heat and power (CHP), carbon capture, and the potential introduction of biomass feedstocks. However, these options are not addressed in this report as this report is focused on developing the modeling methodology and assessing fuels savings measures. These opportunities to further reduce refinery sector CO 2 emissions and are recommended for further research and analysis.« less
Wastewater recycling and heat reclamation project: Red Lion Central Laundry, Portland, Oregon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garlick, T.F.; Halverson, M.A.; Ledbetter, M.R.
1997-06-01
This report discusses water, energy, and cost savings that can be achieved in a commercial laundry through the use of a wastewater recycling and heat recovery system. Cost savings are achieved through reductions in water use, reduction in sewage charges (typically based on water use), reductions in water heating energy, and potential reductions in water treatment chemicals because the recycled water has already been treated with soaps and conditioners. A recovery system saves water by recycling wash water that would normally be dumped into the city sewage system. Recycling the wash water produces considerable energy savings because the recycled watermore » has a higher temperature than fresh water. As a result, a hot water heater consumes less energy to heat the recycled water. The demonstration project discussed in this report was based in a large commercial laundry in Portland, Oregon. The laundry serves a large hotel/motel chain and processes an average of 25,000 pounds of laundry per day. A wastewater recovery system using a membrane microfiltration unit (MFU) was installed in the laundry in September 1995. Time series data of the water and energy consumption of the laundry were taken before and after installation of the MFU. Energy savings were measured by performing a thermal energy balance around the washing machines. Water savings were calculated by metering volumetric flow rates. After a period of approximately five months, the MFU has achieved final results of 52 percent savings in water consumption and 44 percent savings in energy to heat water. This five-month period represents a learning curve during which several small technical improvements were made to the MFU and laundry staff adjusted laundry operations to maximize the benefits of the MFU. An economic analysis discusses the impact of capital investment, daily consumption, and local utility rates on the payback period.« less
An actuarial approach to retrofit savings in buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Subbarao, Krishnappa; Etingov, Pavel V.; Reddy, T. A.
An actuarial method has been developed for determining energy savings from retrofits from energy use data for a number of buildings. This method should be contrasted with the traditional method of using pre- and post-retrofit data on the same building. This method supports the U.S. Department of Energy Building Performance Database of real building performance data and related tools that enable engineering and financial practitioners to evaluate retrofits. The actuarial approach derives, from the database, probability density functions (PDFs) for energy savings from retrofits by creating peer groups for the user’s pre post buildings. From the energy use distribution ofmore » the two groups, the savings PDF is derived. This provides the basis for engineering analysis as well as financial risk analysis leading to investment decisions. Several technical issues are addressed: The savings PDF is obtained from the pre- and post-PDF through a convolution. Smoothing using kernel density estimation is applied to make the PDF more realistic. The low data density problem can be mitigated through a neighborhood methodology. Correlations between pre and post buildings are addressed to improve the savings PDF. Sample size effects are addressed through the Kolmogorov--Smirnov tests and quantile-quantile plots.« less
ORNL takes energy-efficient housing to a new level
None
2017-12-09
Oak Ridge National Laboratory, TVA and the Department of Energy are taking energy-saving research into a West Knox County neighborhood. In the Campbell Creek subdivision, ORNL researchers have helped builders to construct three homes with three different levels of energy-saving features.
The Energy Cost of Automobiles
ERIC Educational Resources Information Center
Berry, R. Stephen; Fels, Margaret F.
1973-01-01
Presents two respective comparisons between ideal and real energy cost for the manufacture of a new automobile and between free energy savings from processing the old automobile into low and high grade scraps. Suggests the wasted thermodynamic potential should be considered in making decisions about energy savings. (CC)
Nonprice incentives and energy conservation
Asensio, Omar I.; Delmas, Magali A.
2015-01-01
In the electricity sector, energy conservation through technological and behavioral change is estimated to have a savings potential of 123 million metric tons of carbon per year, which represents 20% of US household direct emissions in the United States. In this article, we investigate the effectiveness of nonprice information strategies to motivate conservation behavior. We introduce environment and health-based messaging as a behavioral strategy to reduce energy use in the home and promote energy conservation. In a randomized controlled trial with real-time appliance-level energy metering, we find that environment and health-based information strategies, which communicate the environmental and public health externalities of electricity production, such as pounds of pollutants, childhood asthma, and cancer, outperform monetary savings information to drive behavioral change in the home. Environment and health-based information treatments motivated 8% energy savings versus control and were particularly effective on families with children, who achieved up to 19% energy savings. Our results are based on a panel of 3.4 million hourly appliance-level kilowatt–hour observations for 118 residences over 8 mo. We discuss the relative impacts of both cost-savings information and environmental health messaging strategies with residential consumers. PMID:25583494
Nonprice incentives and energy conservation.
Asensio, Omar I; Delmas, Magali A
2015-02-10
In the electricity sector, energy conservation through technological and behavioral change is estimated to have a savings potential of 123 million metric tons of carbon per year, which represents 20% of US household direct emissions in the United States. In this article, we investigate the effectiveness of nonprice information strategies to motivate conservation behavior. We introduce environment and health-based messaging as a behavioral strategy to reduce energy use in the home and promote energy conservation. In a randomized controlled trial with real-time appliance-level energy metering, we find that environment and health-based information strategies, which communicate the environmental and public health externalities of electricity production, such as pounds of pollutants, childhood asthma, and cancer, outperform monetary savings information to drive behavioral change in the home. Environment and health-based information treatments motivated 8% energy savings versus control and were particularly effective on families with children, who achieved up to 19% energy savings. Our results are based on a panel of 3.4 million hourly appliance-level kilowatt-hour observations for 118 residences over 8 mo. We discuss the relative impacts of both cost-savings information and environmental health messaging strategies with residential consumers.
An energy-aware routing protocol for query-based applications in wireless sensor networks.
Ahvar, Ehsan; Ahvar, Shohreh; Lee, Gyu Myoung; Crespi, Noel
2014-01-01
Wireless sensor network (WSN) typically has energy consumption restriction. Designing energy-aware routing protocol can significantly reduce energy consumption in WSNs. Energy-aware routing protocols can be classified into two categories, energy savers and energy balancers. Energy saving protocols are used to minimize the overall energy consumed by a WSN, while energy balancing protocols attempt to efficiently distribute the consumption of energy throughout the network. In general terms, energy saving protocols are not necessarily good at balancing energy consumption and energy balancing protocols are not always good at reducing energy consumption. In this paper, we propose an energy-aware routing protocol (ERP) for query-based applications in WSNs, which offers a good trade-off between traditional energy balancing and energy saving objectives and supports a soft real time packet delivery. This is achieved by means of fuzzy sets and learning automata techniques along with zonal broadcasting to decrease total energy consumption.
An Energy-Aware Routing Protocol for Query-Based Applications in Wireless Sensor Networks
Crespi, Noel
2014-01-01
Wireless sensor network (WSN) typically has energy consumption restriction. Designing energy-aware routing protocol can significantly reduce energy consumption in WSNs. Energy-aware routing protocols can be classified into two categories, energy savers and energy balancers. Energy saving protocols are used to minimize the overall energy consumed by a WSN, while energy balancing protocols attempt to efficiently distribute the consumption of energy throughout the network. In general terms, energy saving protocols are not necessarily good at balancing energy consumption and energy balancing protocols are not always good at reducing energy consumption. In this paper, we propose an energy-aware routing protocol (ERP) for query-based applications in WSNs, which offers a good trade-off between traditional energy balancing and energy saving objectives and supports a soft real time packet delivery. This is achieved by means of fuzzy sets and learning automata techniques along with zonal broadcasting to decrease total energy consumption. PMID:24696640
76 FR 6653 - Public Housing Capital Fund Program
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-07
...; heating system replacements; wall insulation; site-based generation; advanced energy savings technologies...; wall insulation; site-based generation; advanced energy savings technologies, including renewable...
Army Reserve 63d RSC Achieves 85% Savings in Parking Lot Lighting
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Case study describes how the Army Reserve 63d Regional Support Command (RSC) achieved 85% energy savings and $4,000 per year in cost savings by replacing 12 old light fixtures with light-emitting diode fixtures in the military equipment parking area. This project was part of a camp-wide parking lighting retrofit which, on average, delivered 78% energy savings and a simple payback of 4.4 years.
NASA Technical Reports Server (NTRS)
Plankey, B.
1981-01-01
A computer program called ECPVER (Energy Consumption Program - Verification) was developed to simulate all energy loads for any number of buildings. The program computes simulated daily, monthly, and yearly energy consumption which can be compared with actual meter readings for the same time period. Such comparison can lead to validation of the model under a variety of conditions, which allows it to be used to predict future energy saving due to energy conservation measures. Predicted energy saving can then be compared with actual saving to verify the effectiveness of those energy conservation changes. This verification procedure is planned to be an important advancement in the Deep Space Network Energy Project, which seeks to reduce energy cost and consumption at all DSN Deep Space Stations.
Kim, Dongsu; Cox, Sam J.; Cho, Heejin; ...
2017-05-22
Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assessmore » the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Dongsu; Cox, Sam J.; Cho, Heejin
Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assessmore » the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.« less
Data Center Energy Practitioner (DCEP) Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Traber, Kim; Salim, Munther; Sartor, Dale A.
2016-02-02
The main objective for the DCEP program is to raise the standards of those involved in energy assessments of data centers to accelerate energy savings. The program is driven by the fact that significant knowledge, training, and skills are required to perform accurate energy assessments. The program will raise the confidence level in energy assessments in data centers. For those who pass the exam, the program will recognize them as Data Center Energy Practitioners (DCEPs) by issuing a certificate. Hardware req.: PC, MAC; Software Req.: Windows; Related/Auxiliary software--MS Office; Type of files: executable modules, user guide; Documentation: e-user manual; Documentation:more » http://www.1.eere.energy.gov/industry/datacenters/ 12/10/15-New Documentation URL: https://datacenters.lbl.gov/dcep« less
Identification of cost effective energy conservation measures
NASA Technical Reports Server (NTRS)
Bierenbaum, H. S.; Boggs, W. H.
1978-01-01
In addition to a successful program of readily implemented conservation actions for reducing building energy consumption at Kennedy Space Center, recent detailed analyses have identified further substantial savings for buildings representative of technical facilities designed when energy costs were low. The techniques employed for determination of these energy savings consisted of facility configuration analysis, power and lighting measurements, detailed computer simulations and simulation verifications. Use of these methods resulted in identification of projected energy savings as large as $330,000 a year (approximately two year break-even period) in a single building. Application of these techniques to other commercial buildings is discussed
Creating Jobs through Energy Efficiency Using Wisconsin's Successful Focus on Energy Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akhtar, Masood; Corrigan, Edward; Reitter, Thomas
2012-03-30
The purpose of this project was to provide administrative and technical support for the completion of energy efficiency projects that reduce energy intensity and create or save Wisconsin industrial jobs. All projects have been completed. Details in the attached reports include project management, job development, and energy savings for each project.
Asetek's Warm-Water Liquid Cooling System Yields Energy Cost Savings at
NREL | Energy Systems Integration Facility | NREL Asetek Asetek's Warm-Water Liquid Cooling System Yields Energy Cost Savings at NREL Asetek's RackCDU liquid cooling system was installed and tested at the Energy Systems Integration Facility's (ESIF's) ultra-energy-efficient high-performance
Energy Saving Homes and Buildings - Continuum Magazine | NREL
Spring 2014 / Issue 6 Continuum. Clean Energy Innovation at NREL Energy Saving Homes and Buildings Continuum showcases NREL's unique research capabilities and most impactful clean energy innovations. Dan Says From our director Dan says NREL Provides a Foundation for Home Energy Performance 01 NREL Provides
Inclusion of cool roofs in nonresidential Title 24 prescriptiverequirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levinson, Ronnen; Akbari, Hashem; Konopacki, Steve
2003-07-01
Roofs that have high solar reflectance (high ability toreflect sunlight) and high thermal emittance (high ability to radiateheat) tend to stay cool in the sun. The same is true of low-emittanceroofs with exceptionally high solar reflectance. Substituting a cool rooffor a non-cool roof tends to decrease cooling electricity use, coolingpower demand, and cooling-equipment capacity requirements, while slightlyincreasing heating energy consumption. Cool roofs can also lower citywideambient air temperature in summer, slowing ozone formation and increasinghuman comfort.DOE-2.1E building energy simulations indicate that use of acool roofing material on a prototypical California nonresidential (NR)building with a low-sloped roof yields average annual coolingmore » energysavings of approximately 3.2 kW h/m2 (300 kW h/1000 ft2), average annualnatural gas deficits of 5.6 MJ/m2 (4.9 therm/1000 ft2), average annualsource energy savings of 30 MJ/m2 (2.6 MBTU/1000 ft2), and average peakpower demand savings of 2.1 W/m2 (0.19 kW/1000 ft2). The 15-year netpresent value (NPV) of energy savings averages $4.90/m2 ($450/1000 ft2)with time-dependent valuation (TDV), and $4.00/m2 ($370/1000 ft2) withoutTDV. When cost savings from downsizing cooling equipment are included,the average total savings (15-year NPV+equipment savings) rises to$5.90/m2 ($550/1000 ft2) with TDV, and to $5.00/m2 ($470/1000 ft2)without TDV.Total savings range from 1.90 to 8.30 $/m2 (0.18 0.77 $/ft2)with TDV, and from 1.70 to 7.10 $/m2 (0.16 0.66 $/ft2) without TDV,across California's 16 climate zones. The typical cost premium for a coolroof is 0.00 2.20 $/m2 (0.00 0.20 $/ft2). Cool roofs with premiums up to$2.20/m2 ($0.20/ft2) are expected to be cost effective in climate zones 216; those with premiums not exceeding $1.90/m2 ($0.18/ft2) are expectedto be also cost effective in climate zone 1. Hence, this study recommendsthat the year-2005 California building energy efficiency code (Title 24,Part 6 of the California Code of Regulations) for NR buildings withlow-sloped roofs include a cool-roof prescriptive requirement in allCalifornia climate zones. Buildings with roofs that do not meetprescriptive requirements may comply with the code via an"overall-envelope" approach (non-metal roofs only), or via a performanceapproach (all roof types).« less
State Policy Initiatives for Financing Energy Efficiency in Public Buildings.
ERIC Educational Resources Information Center
Business Officer, 1984
1984-01-01
Alternative financing methods (other than state financing) for developing cost-effective energy efficiency projects are discussed. It is suggested that by properly financing energy efficiency investments, state campuses can generate immediate positive cash savings. The following eight initiatives for maximizing energy savings potential are…
Stretching Energy Dollars for Healthy Schools
ERIC Educational Resources Information Center
Angerame, Timothy
2011-01-01
When financial savings are critical to every institution, facility managers demand even more from their energy systems while looking to spend less. One way to achieve significant energy savings and healthy schools without making a substantial capital investment is through energy monitoring and chiller plant optimization. The greatest energy…
Performance Contracting: Taking School Technology Green
ERIC Educational Resources Information Center
Taival, Dane
2009-01-01
Energy efficiency makes fiscal and environmental sense, and so does energy savings performance contracting. Because an energy savings performance contract can create a self-funding package of products and services that reduce energy and operating costs, over time, school districts' sometimes-large initial investment in emerging technologies saves…
Carbon and energy saving markets in compressed air
NASA Astrophysics Data System (ADS)
Cipollone, R.
2015-08-01
CO2 reduction and fossil fuel saving represent two of the cornerstones of the environmental commitments of all the countries of the world. The first engagement is of a medium to long term type, and unequivocally calls for a new energetic era. The second delays in time the fossil fuel technologies to favour an energetic transition. In order to sustain the two efforts, new immaterial markets have been established in almost all the countries of the world, whose exchanges (purchases and sales) concern CO2 emissions and equivalent fossil fuels that have not been emitted or burned. This paper goes deep inside two aspects not yet exploited: specific CO2 emissions and equivalent fossil fuel burned, as a function of compressed air produced. Reference is made to the current compressor technology, carefully analysing CAGI's (Compressed Air Gas Institute) data and integrating it with the PNUEROP (European Association of manufacturers of compressors, vacuum pumps, pneumatic tools and allied equipment) contribution on the compressor European market. On the base of energy saving estimates that could be put in place, this article also estimates the financial value of the CO2 emissions and fossil fuels avoided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, S.; Sartor, D.
2005-08-15
Federal agencies often ask if Energy Savings PerformanceContracts (ESPCs) result in the energy and cost savings projected duringthe project development phase. After investing in ESPCs, federal agenciesexpect a reduction in the total energy use and energy cost at the agencylevel. Such questions about the program are common when implementing anESPC project. But is this a fair or accurate perception? Moreimportantly, should the federal agencies evaluate the success or failureof ESPCs by comparing the utility costs before and after projectimplementation?In fact, ESPC contracts employ measurement andverification (M&V) protocols to measure and ensure kilowatt-hour orBTU savings at the project level. In mostmore » cases, the translation toenergy cost savings is not based on actual utility rate structure, but acontracted utility rate that takes the existing utility rate at the timethe contract is signed with a clause to escalate the utility rate by afixed percentage for the duration of the contract. Reporting mechanisms,which advertise these savings in dollars, may imply an impact to budgetsat a much higher level depending on actual utility rate structure. FEMPhas prepared the following analysis to explain why the utility billreduction may not materialize, demonstrate its larger implication onagency s energy reduction goals, and advocate setting the rightexpectations at the outset to preempt the often asked question why I amnot seeing the savings in my utility bill?« less
Nuclear and Solar Energy: Implications for Homeland Security
2008-12-01
of New Nuclear Plants?" Nuclear Engineering International, March 31, 2004, 14. 10 Gwyneth Cravens, Power to Save the World: The Truth about...Pueblo West, CO: Vales Lake Pub, 2004), 98. 12 Cravens, Power to Save the World: The Truth about Nuclear Energy, 249. 13 Jerry Taylor, "Powering...Cravens, Power to Save the World: The Truth about Nuclear Energy, 152. 30 William Langewiesche, The Atomic Bazaar: Dispatches from the Underground World
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heaney, M.; Polly, B.
2015-04-30
This report presents an analysis of data for residential single-family projects reported by 37 organizations that were awarded federal financial assistance (cooperative agreements or grants) by the U.S. Department of Energy’s Better Buildings Neighborhood Program.1 The report characterizes the energy-efficiency measures installed for single-family residential projects and analyzes energy savings and savings prediction accuracy for measures installed in a subset of those projects.
Field testing energy-saving hermetic compressors in residential refrigerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauber, R.S.; Middleton, M.G.
The design of an energy-saving compressor for low back pressure applications is reviewed. Calorimeter performance results are stated for two sizes of the efficient design and compared with performance test results for a standard compressor. Power consumption of a refrigerator-freezer is given with a standard compressor and with the energy-saving compressor. The preparation of the refrigerators used in the field test is discussed, along with the criteria used in selecting the instrumentation for the project. Results of the energy-saving compressor in the field test, along with a comparison to a standard production compressor, are presented. Some conclusions are drawn, basedmore » on the data, in relation to important factors in residential refrigerator power consumption.« less
Field testing energy-saving hermetic compressors in residential refrigerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauber, R.S.; Middleton, M.G.
The design of an energy saving compressor for low back pressure applications is reviewed. Calorimeter performance results are stated for two sizes of the efficient design and compared with performance test results for a standard compressor. Power consumption of a refrigerator-freezer is given with a standard compressor and with the energy saving compressor. The preparation of the refrigerators used in the field test are discussed along with the criteria used in selecting the instrumentation for the project. Results of the energy saving compressor in the field test along with a comparison to a standard production compressor are presented. Some conclusionsmore » are drawn, based on the data, in relation to important factors in residential refrigerator power consumption.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Nan; Romankiewicz, John; Vine, Edward
2012-12-15
In recent years, the number of energy efficiency policies implemented has grown very rapidly as energy security and climate change have become top policy issues for many governments around the world. Within the sphere of energy efficiency policy, governments (federal and local), electric utilities, and other types of businesses and institutions are implementing a wide variety of programs to spread energy efficiency practices in industry, buildings, transport, and electricity. As programs proliferate, there is an administrative and business imperative to evaluate the savings and processes of these programs to ensure that program funds spent are indeed leading to a moremore » energy-efficient economy.« less
Programming models for energy-aware systems
NASA Astrophysics Data System (ADS)
Zhu, Haitao
Energy efficiency is an important goal of modern computing, with direct impact on system operational cost, reliability, usability and environmental sustainability. This dissertation describes the design and implementation of two innovative programming languages for constructing energy-aware systems. First, it introduces ET, a strongly typed programming language to promote and facilitate energy-aware programming, with a novel type system design called Energy Types. Energy Types is built upon a key insight into today's energy-efficient systems and applications: despite the popular perception that energy and power can only be described in joules and watts, real-world energy management is often based on discrete phases and modes, which in turn can be reasoned about by type systems very effectively. A phase characterizes a distinct pattern of program workload, and a mode represents an energy state the program is expected to execute in. Energy Types is designed to reason about energy phases and energy modes, bringing programmers into the optimization of energy management. Second, the dissertation develops Eco, an energy-aware programming language centering around sustainability. A sustainable program built from Eco is able to adaptively adjusts its own behaviors to stay on a given energy budget, avoiding both deficit that would lead to battery drain or CPU overheating, and surplus that could have been used to improve the quality of the program output. Sustainability is viewed as a form of supply and demand matching, and a sustainable program consistently maintains the equilibrium between supply and demand. ET is implemented as a prototyped compiler for smartphone programming on Android, and Eco is implemented as a minimal extension to Java. Programming practices and benchmarking experiments in these two new languages showed that ET can lead to significant energy savings for Android Apps and Eco can efficiently promote battery awareness and temperature awareness in real-world Java programs.
Rapid calculation method for Frenkel-type two-exciton states in one to three dimensions
NASA Astrophysics Data System (ADS)
Ajiki, Hiroshi
2014-07-01
Biexciton and two-exciton dissociated states of Frenkel-type excitons are well described by a tight-binding model with a nearest-neighbor approximation. Such two-exciton states in a finite-size lattice are usually calculated by numerical diagonalization of the Hamiltonian, which requires an increasing amount of computational time and memory as the lattice size increases. I develop here a rapid, memory-saving method to calculate the energies and wave functions of two-exciton states by employing a bisection method. In addition, an attractive interaction between two excitons in the tight-binding model can be obtained directly so that the biexciton energy agrees with the observed energy, without the need for the trial-and-error procedure implemented in the numerical diagonalization method.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-27
... facilitate electronic service, persons with Internet access who will eFile a document and/or be listed as a... Technology Savings LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Energy Technology Savings LLC's application for market-based rate authority, with an accompanying rate...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This case study was prepared for the Industrial Technologies Program of the U.S. Department of Energy (DOE); it describes the energy and costs savings resulting from improving the compressed air system of a large Sara Lee bakery in Sacramento, California. The compressed air system supports many operations of the bread-making machines, and it had been performing poorly. A specialist from Draw Professional Services, a DOE Allied Partner, evaluated the system, and his suggestions included repairing a controller, fixing leaks, and replacing a compressor with a new one fitted with an energy-saving variable-speed drive. As a result, the bakery has reducedmore » its energy use by 471,000 kilowatt-hours annually and is saving $50,000 per year in operating and maintenance costs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Littleton, Harry; Griffin, John
2011-07-31
This project was a subtask of Energy Saving Melting and Revert Reduction Technology (Energy SMARRT) Program. Through this project, technologies, such as computer modeling, pattern quality control, casting quality control and marketing tools, were developed to advance the Lost Foam Casting process application and provide greater energy savings. These technologies have improved (1) production efficiency, (2) mechanical properties, and (3) marketability of lost foam castings. All three reduce energy consumption in the metals casting industry. This report summarizes the work done on all tasks in the period of January 1, 2004 through June 30, 2011. Current (2011) annual energy savingmore » estimates based on commercial introduction in 2011 and a market penetration of 97% by 2020 is 5.02 trillion BTU's/year and 6.46 trillion BTU's/year with 100% market penetration by 2023. Along with these energy savings, reduction of scrap and improvement in casting yield will result in a reduction of the environmental emissions associated with the melting and pouring of the metal which will be saved as a result of this technology. The average annual estimate of CO2 reduction per year through 2020 is 0.03 Million Metric Tons of Carbon Equivalent (MM TCE).« less
Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, A.; Lubliner, M.; Howard, L.
2013-10-01
This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilation strategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7.
A Novel Energy Saving Algorithm with Frame Response Delay Constraint in IEEE 802.16e
NASA Astrophysics Data System (ADS)
Nga, Dinh Thi Thuy; Kim, Mingon; Kang, Minho
Sleep-mode operation of a Mobile Subscriber Station (MSS) in IEEE 802.16e effectively saves energy consumption; however, it induces frame response delay. In this letter, we propose an algorithm to quickly find the optimal value of the final sleep interval in sleep-mode in order to minimize energy consumption with respect to a given frame response delay constraint. The validations of our proposed algorithm through analytical results and simulation results suggest that our algorithm provide a potential guidance to energy saving.
78 FR 24736 - Energy Savings Performance Contracts: Extension of Comment Period
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... legislated and executive-ordered energy, greenhouse gas, and water goals. These are delivered through project..., obtaining, and implementing project funding for energy projects through the use of ESPCs. ESPCs allow Federal agencies to accomplish energy savings projects without up-front capital costs. In an ESPC, a...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This two-page performance spotlight describes how, in 2004, Austin Energy (the electric utility for the city of Austin, Texas) began saving about $1.2 million in energy and maintenance costs annually as a direct result of a pumping system efficiency proj
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This two-page performance spotlight describes how, in 2004, Austin Energy (the electric utility for the city of Austin, Texas) began saving about $1.2 million in energy and maintenance costs annually as a direct result of a pumping system efficiency project.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
This paper is designed for companies looking to cut costs through energy savings, ratepayer-funded program administrators interested in increasing large industrial company participation in energy efficiency program offerings, and state utility commissions.
10 CFR 436.32 - Qualified contractors lists.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Qualified contractors lists. 436.32 Section 436.32 Energy... Procedures for Energy Savings Performance Contracting § 436.32 Qualified contractors lists. (a) DOE shall... energy savings performance contracts. (c) DOE may remove a firm from DOE's list of qualified contractors...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucas, Robert G.; Taylor, Zachary T.; Mendon, Vrushali V.
2012-06-15
The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Alabama homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Alabama homeowners will save $2,117 over 30 years under the 2009 IECC, with savings still higher at $6,182 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for both the 2009 and 2012 IECC. Average annual energy savings aremore » $168 for the 2009 IECC and $462 for the 2012 IECC.« less
Concerted drive to cut carbon footprint.
2015-04-01
In 2013 Peter Sellars, head of Profession for Estates & Facilities Policy at the Department of Health, successfully bid for £50 million from the Treasury to help finance a range of 'spend-to-save' energy efficiency initiatives across the NHS in England. In all 117 energy efficiency projects were initiated across 48 English NHS organisations--funded through a dedicated NHS Energy Efficiency Fund. An independent analysis for the DH, NHS Energy Efficiency Fund Final Report, Summary 2014, by Professor Alan Short of Cambridge University's Department of Architecture, says the projects are already on track to save 100.6 million kg of CO2 annually, and some 2.4% of the entire 2012 NHS building energy-related carbon footprint, delivering annual energy savings of 160.5 million kWh (equivalent to boiling 3.34 billion cups of tea a year.) The Report--reproduced in large part here--summarises the schemes' preliminary outcomes, and makes recommendations for policy-makers implementing similar energy-saving funding schemes in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ian Metzger, Jesse Dean
2010-12-31
This software requires inputs of simple water fixture inventory information and calculates the water/energy and cost benefits of various retrofit opportunities. This tool includes water conservation measures for: Low-flow Toilets, Low-flow Urinals, Low-flow Faucets, and Low-flow Showheads. This tool calculates water savings, energy savings, demand reduction, cost savings, and building life cycle costs including: simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mittal, Sparsh; Zhang, Zhao
With each CMOS technology generation, leakage energy consumption has been dramatically increasing and hence, managing leakage power consumption of large last-level caches (LLCs) has become a critical issue in modern processor design. In this paper, we present EnCache, a novel software-based technique which uses dynamic profiling-based cache reconfiguration for saving cache leakage energy. EnCache uses a simple hardware component called profiling cache, which dynamically predicts energy efficiency of an application for 32 possible cache configurations. Using these estimates, system software reconfigures the cache to the most energy efficient configuration. EnCache uses dynamic cache reconfiguration and hence, it does not requiremore » offline profiling or tuning the parameter for each application. Furthermore, EnCache optimizes directly for the overall memory subsystem (LLC and main memory) energy efficiency instead of the LLC energy efficiency alone. The experiments performed with an x86-64 simulator and workloads from SPEC2006 suite confirm that EnCache provides larger energy saving than a conventional energy saving scheme. For single core and dual-core system configurations, the average savings in memory subsystem energy over a shared baseline configuration are 30.0% and 27.3%, respectively.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2003-07-01
Rohm and Haas conducted a plant-wide energy assessment at its Knoxville, Tennessee, chemicals manufacturing facility. The assessment identified potential annual energy savings of nearly 47,000 MMBtu in steam and fuel and 11,000 MWh in electricity. Annual cost savings were estimated at almost$1.5 million. After the assessment was replicated in California and Kentucky plants, the companys additional estimated cost savings were$500,000 annually. Additional annual energy savings were about 23,000 MMBtu and 6,000 MWh. The assessments also indicated the plants would reduce nitrous oxide emissions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2003-05-01
Rohm and Haas conducted a plant-wide energy assessment at its Knoxville, Tennessee, chemicals manufacturing facility. The assessment identified potential annual energy savings of nearly 47,000 MMBtu in steam and fuel and 11,000 MWh in electricity. Annual cost savings were estimated at almost $1.5 million. After the assessment was replicated in California and Kentucky plants, the company's additional estimated cost savings were $500,000 annually. Additional annual energy savings were about 23,000 MMBtu and 6,000 MWh. The assessments also indicated the plants would reduce nitrous oxide emissions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2003-07-01
The plant-wide energy-efficiency assessment performed in 2001 at the Alcoa World Alumina Arkansas Operations in Bauxite, Arkansas, identified seven opportunities to save energy and reduce costs. By implementing five of these improvements, the facility can save 15,100 million British thermal units per year in natural gas and 8.76 million kilowatt-hours per year in electricity. This translates into approximate annual savings of$925,300 in direct energy costs and non-fuel operating and maintenance costs. The required capital investment is estimated at$271,200. The average payback period for all five projects would be approximately 8 months.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2003-07-01
The plant-wide energy-efficiency assessment performed in 2001 at the Alcoa World Alumina Arkansas Operations in Bauxite, Arkansas, identified seven opportunities to save energy and reduce costs. By implementing five of these improvements, the facility can save 15,100 million British thermal units per year in natural gas and 8.76 million kilowatt-hours per year in electricity. This translates into approximate annual savings of $925,300 in direct energy costs and non-fuel operating and maintenance costs. The required capital investment is estimated at $271,200. The average payback period for all five projects would be approximately 8 months.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W; Gowans, Dakers; Telarico, Chad
The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, David M.; Belzer, David B.; Livingston, Olga V.
Pacific Northwest National Laboratory (PNNL) modeled the employment impacts of a major national initiative to accelerate energy efficiency trends at one of two levels: • 15 percent savings by 2030. In this scenario, efficiency activities save about 15 percent of the Annual Energy Outlook (AEO) Reference Case electricity consumption by 2030. It is assumed that additional energy savings in both the residential and commercial sectors begin in 2015 at zero, and then increase in an S-shaped market penetration curve, with the level of savings equal to about 7.0 percent of the AEO 2014 U.S. national residential and commercial electricity consumptionmore » saved by 2020, 14.8 percent by 2025, and 15 percent by 2030. • 10 percent savings by 2030. In this scenario, additional savings begin at zero in 2015, increase to 3.8 percent in 2020, 9.8 percent by 2025, and 10 percent of the AEO reference case value by 2030. The analysis of the 15 percent case indicates that by 2030 more than 300,000 new jobs would likely result from such policies, including an annual average of more than 60,000 jobs directly supporting the installation and maintenance of energy efficiency measures and practices. These are new jobs resulting initially from the investment associated with the construction of more energy-efficient new buildings or the retrofit of existing buildings and would be sustained for as long as the investment continues. Based on what is known about the current level of building-sector energy efficiency jobs, this would represent an increase of more than 10 percent from the current estimated level of over 450,000 such jobs. The more significant and longer-lasting effect comes from the redirection of energy bill savings toward the purchase of other goods and services in the general economy, with its attendant influence on increasing the total number of jobs. This example analysis utilized PNNL’s ImSET model, a modeling framework that PNNL has used over the past two decades to assess the economic impacts of the U.S. Department of Energy’s (DOE’s) energy efficiency programs in the buildings sector.« less
NASA Astrophysics Data System (ADS)
Aziz, Mohammad Abdul; Al-khulaidi, Rami Ali; Rashid, MM; Islam, M. R.; Rashid, MAN
2017-03-01
In this research, a development and performance test of a fixed-bed batch type pyrolysis reactor for pilot scale pyrolysis oil production was successfully completed. The characteristics of the pyrolysis oil were compared to other experimental results. A solid horizontal condenser, a burner for furnace heating and a reactor shield were designed. Due to the pilot scale pyrolytic oil production encountered numerous problems during the plant’s operation. This fixed-bed batch type pyrolysis reactor method will demonstrate the energy saving concept of solid waste tire by creating energy stability. From this experiment, product yields (wt. %) for liquid or pyrolytic oil were 49%, char 38.3 % and pyrolytic gas 12.7% with an operation running time of 185 minutes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Carlson, Stephen
This Commercial and Industrial Lighting Controls Evaluation Protocol (the protocol) describes methods to account for energy savings resulting from programmatic installation of lighting control equipment in large populations of commercial, industrial, government, institutional, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. When lighting controls are installed in conjunction with a lighting retrofit project, the lighting control savings must be calculated parametrically with the lighting retrofit project so savings are not double counted.
Potential energy savings in buildings by an urban tree planting programme in California
E.G. McPherson; J.R. Simpson
2003-01-01
Tree canopy cover data from aerial photographs and building energy simulations were applied to estimate energy savings from existing trees and new plantings in California. There are approximately 177.3 million energy-conserving trees in California communities and 241.6 million empty planting sites. Existing trees are projected to reduce annual air conditioning energy...
Quantifying Adoption Rates and Energy Savings Over Time for Advanced Manufacturing Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanes, Rebecca; Carpenter Petri, Alberta C; Riddle, Matt
Energy-efficient manufacturing technologies can reduce energy consumption and lower operating costs for an individual manufacturing facility, but increased process complexity and the resulting risk of disruption means that manufacturers may be reluctant to adopt such technologies. In order to quantify potential energy savings at scales larger than a single facility, it is necessary to account for how quickly and how widely the technology will be adopted by manufacturers. This work develops a methodology for estimating energy-efficient manufacturing technology adoption rates using quantitative, objectively measurable technology characteristics, including energetic, economic and technical criteria. Twelve technology characteristics are considered, and each characteristicmore » is assigned an importance weight that reflects its impact on the overall technology adoption rate. Technology characteristic data and importance weights are used to calculate the adoption score, a number between 0 and 1 that represents how quickly the technology is likely to be adopted. The adoption score is then used to estimate parameters for the Bass diffusion curve, which quantifies the change in the number of new technology adopters in a population over time. Finally, energy savings at the sector level are calculated over time by multiplying the number of new technology adopters at each time step with the technology's facility-level energy savings. The proposed methodology will be applied to five state-of-the-art energy-efficient technologies in the carbon fiber composites sector, with technology data obtained from the Department of Energy's 2016 bandwidth study. Because the importance weights used in estimating the Bass curve parameters are subjective, a sensitivity analysis will be performed on the weights to obtain a range of parameters for each technology. The potential energy savings for each technology and the rate at which each technology is adopted in the sector are quantified and used to identify the technologies which offer the greatest cumulative sector-level energy savings over a period of 20 years. Preliminary analysis indicates that relatively simple technologies, such as efficient furnaces, will be adopted more quickly and result in greater cumulative energy savings compared to more complex technologies that require process retrofitting, such as advanced control systems.« less
Keys to the House: Unlocking Residential Savings With Program Models for Home Energy Upgrades
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grevatt, Jim; Hoffman, Ian; Hoffmeyer, Dale
After more than 40 years of effort, energy efficiency program administrators and associated contractors still find it challenging to penetrate the home retrofit market, especially at levels commensurate with state and federal goals for energy savings and emissions reductions. Residential retrofit programs further have not coalesced around a reliably successful model. They still vary in design, implementation and performance, and they remain among the more difficult and costly options for acquiring savings in the residential sector. If programs are to contribute fully to meeting resource and policy objectives, administrators need to understand what program elements are key to acquiring residentialmore » savings as cost effectively as possible. To that end, the U.S. Department of Energy (DOE) sponsored a comprehensive review and analysis of home energy upgrade programs with proven track records, focusing on those with robustly verified savings and constituting good examples for replication. The study team reviewed evaluations for the period 2010 to 2014 for 134 programs that are funded by customers of investor-owned utilities. All are programs that promote multi-measure retrofits or major system upgrades. We paid particular attention to useful design and implementation features, costs, and savings for nearly 30 programs with rigorous evaluations of performance. This meta-analysis describes program models and implementation strategies for (1) direct install retrofits; (2) heating, ventilating and air-conditioning (HVAC) replacement and early retirement; and (3) comprehensive, whole-home retrofits. We analyze costs and impacts of these program models, in terms of both energy savings and emissions avoided. These program models can be useful guides as states consider expanding their strategies for acquiring energy savings as a resource and for emissions reductions. We also discuss the challenges of using evaluations to create program models that can be confidently applied in multiple jurisdictions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, James
Strategic energy management (SEM) focuses on achieving energy-efficiency improvements through systematic and planned changes in facility operations, maintenance, and behaviors (OM&B) and capital equipment upgrades in large energy-using facilities, including industrial buildings, commercial buildings, and multi-facility organizations such as campuses or communities. Facilities can institute a spectrum of SEM actions, ranging from a simple process for regularly identifying energy-savings actions, to establishing a formal, third-party recognized or certified SEM framework for continuous improvement of energy performance. In general, SEM programs that would be considered part of a utility program will contain a set of energy-reducing goals, principles, and practices emphasizingmore » continuous improvements in energy performance or savings through energy management and an energy management system (EnMS).« less
Potential Energy Cost Savings from Increased Commercial Energy Code Compliance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.
2016-08-22
An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed officemore » buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, Anthony L; Martin, Michaela A; Gemmer, Bob
In the wake of Hurricane Katrina and other severe storms in 2005, natural gas supplies were restricted, prices rose, and industry sought ways to reduce its natural gas use and costs. In October 2005, U.S. Department of Energy (DOE) Energy Secretary Bodman launched his Easy Ways to Save Energy campaign with a promise to provide energy assessments to 200 of the largest U.S. manufacturing plants. A major thrust of the campaign was to ensure that the nation's natural gas supplies would be adequate for all Americans, especially during home heating seasons. In a presentation to the National Press Club onmore » October 3, 2005, Secretary Bodman said: 'America's businesses, factories, and manufacturing facilities use massive amounts of energy. To help them during this period of tightening supply and rising costs, our Department is sending teams of qualified efficiency experts to 200 of the nation's most energy-intensive factories. Our Energy Saving Teams will work with on-site managers on ways to conserve energy and use it more efficiently.' DOE's Industrial Technologies Program (ITP) responded to the Secretary's campaign with its Save Energy Now initiative, featuring a new and highly cost-effective form of energy assessments. The approach for these assessments drew heavily on the existing resources of ITP's Technology Delivery component. Over the years, ITP-Technology Delivery had worked with industry partners to assemble a suite of respected software decision tools, proven assessment protocols, training curricula, certified experts, and strong partnerships for deployment. Because of the program's earlier activities and the resources that had been developed, ITP was prepared to respond swiftly and effectively to the sudden need to promote improved industrial energy efficiency. Because of anticipated supply issues in the natural gas sector, the Save Energy Now initiative strategically focused on natural gas savings and targeted the nation's largest manufacturing plants--those that consume a total of 1 trillion British thermal units (Btu) or more annually. The approximately 6800 U.S. facilities that fall into this category collectively account for about 53% of all energy consumed by industry in the United States. The 2006 Save Energy Now energy assessments departed from earlier DOE plant assessments by concentrating solely on steam and process heating systems, which are estimated to account for approximately 74% of all natural gas use for manufacturing. The assessments also integrated a strong training component designed to teach industrial plant personnel how to use DOE's steam or process heating opportunity assessment software tools. This approach had the advantages of promoting strong buy-in of plant personnel for the assessment and its outcomes and preparing them better to independently replicate the assessment process at the company's other facilities. The Save Energy Now initiative also included provisions to help plants that applied for but did not qualify for assessments (based on the 1 trillion Btu criterion). Services offered to these plants included (1) an assessment by one of DOE's 26 university-based Industrial Assessment Centers (IACs), (2) a telephone consultation with a systems expert at the DOE's Energy Efficiency and Renewable Energy Information Center, or (3) other technical materials and services available through ITP (e.g., the Save Energy Now CD). By the end of 2006, DOE had completed all 200 of the promised assessments, identifying potential natural gas savings of more than 50 trillion Btu and energy cost savings of about $500 million. These savings, if fully implemented, could reduce CO2 emissions by 4.04 million metric tons annually. These results, along with the fact that a large percentage of U.S. energy is used by a relatively small number of very large plants, clearly suggest that assessments are an expedient and cost-effective way to significantly affect large amounts of energy use. Building on the success of the 2006 initiative, ITP has expanded the effort in 2007 with the goal of conducting 250 more assessments in large U.S. industrial plants. The 2007 assessments are addressing not only steam and process heating, but also pumping, compressed air, and fan systems. The full report reviews the tools and resources developed by the DOE ITP program before 2006, which are the foundation and catalyst for the Save Energy Now assessment efforts. The report describes the process by which industrial plants applied to obtain assessments in 2006 and the overall process and philosophy of conducting assessments. A comprehensive review of the results from the 2006 assessments is presented, along with a summary of key accomplishments and findings.« less
Macias, Elsa; Suarez, Alvaro; Lloret, Jaime
2013-01-01
Rich-sensor smart phones have made possible the recent birth of the mobile sensing research area as part of ubiquitous sensing which integrates other areas such as wireless sensor networks and web sensing. There are several types of mobile sensing: individual, participatory, opportunistic, crowd, social, etc. The object of sensing can be people-centered or environment-centered. The sensing domain can be home, urban, vehicular… Currently there are barriers that limit the social acceptance of mobile sensing systems. Examples of social barriers are privacy concerns, restrictive laws in some countries and the absence of economic incentives that might encourage people to participate in a sensing campaign. Several technical barriers are phone energy savings and the variety of sensors and software for their management. Some existing surveys partially tackle the topic of mobile sensing systems. Published papers theoretically or partially solve the above barriers. We complete the above surveys with new works, review the barriers of mobile sensing systems and propose some ideas for efficiently implementing sensing, fusion, learning, security, privacy and energy saving for any type of mobile sensing system, and propose several realistic research challenges. The main objective is to reduce the learning curve in mobile sensing systems where the complexity is very high. PMID:24351637
Macias, Elsa; Suarez, Alvaro; Lloret, Jaime
2013-12-16
Rich-sensor smart phones have made possible the recent birth of the mobile sensing research area as part of ubiquitous sensing which integrates other areas such as wireless sensor networks and web sensing. There are several types of mobile sensing: individual, participatory, opportunistic, crowd, social, etc. The object of sensing can be people-centered or environment-centered. The sensing domain can be home, urban, vehicular… Currently there are barriers that limit the social acceptance of mobile sensing systems. Examples of social barriers are privacy concerns, restrictive laws in some countries and the absence of economic incentives that might encourage people to participate in a sensing campaign. Several technical barriers are phone energy savings and the variety of sensors and software for their management. Some existing surveys partially tackle the topic of mobile sensing systems. Published papers theoretically or partially solve the above barriers. We complete the above surveys with new works, review the barriers of mobile sensing systems and propose some ideas for efficiently implementing sensing, fusion, learning, security, privacy and energy saving for any type of mobile sensing system, and propose several realistic research challenges. The main objective is to reduce the learning curve in mobile sensing systems where the complexity is very high.
NASA Astrophysics Data System (ADS)
Rosado, Pablo Javier
Summer urban heat island (UHI) refers to the phenomenon of having higher urban temperatures compared to the those in surrounding suburban and rural areas. Higher urban air temperatures lead to increased cooling demand, accelerates the formation of smog, and contributes to the generation of greenhouse gas emissions. Dark-colored impervious surfaces cover a significant fraction of an urban fabric, and as hot and dry surfaces, are a major contributor to the UHI effect. Adopting solar-reflective ("cool") roofs and cool pavements, and increasing the urban vegetation, are strategies proven to mitigate urban heat islands. These strategies often have an "indirect" effect (ambient cooling) and "direct" effect (change in solar energy flux entering the conditioned space) on the energy use of buildings. This work investigates some elements of the UHI mitigation strategies, specifically the annual direct effect of a cool roof, and the direct and indirect effects of cool pavements. The first topic researched in this paper consists in an experimental assessment of the direct effects from replacing a conventional dark roof with a highly energy-efficient cool roof. The study measures and calculates the annual benefits of the cool roof on the cooling and heating energy uses, and the associated emission reductions. The energy savings attributed to the cool roof are validated by measuring the difference between the homes in the heat loads that entered the conditioned space through the ceiling and HVAC ducts. Fractional annual cooling energy savings (26%) were 2.6 times the 10% daily cooling energy savings measured in a previous study that used a white coating to increase the albedo of an asphalt shingle roof by the same amount (0.44). The improved cooling energy savings (26% vs. 10%) may be attributed to the cool tile's above-sheathing ventilation, rather than to its high thermal mass. The roof also provided energy savings during the heating season, yielding fractional annual gas heating savings of 4% and electric heating savings of 3%. The slightly positive fractional annual heating energy savings likely resulted from the tile roof's high thermal capacitance, which increased the overnight temperature of the attic air. Thus cool tile roofs should be perceived as a technology that provides energy and environmental benefits during the cooling season as well as the heating season. The second topic investigates the direct and indirect effects of cool pavements on the energy use of California's building stock. First, a simple urban canyon model was developed to calculate the canyon albedo after the user provides the solar position, canyon orientation, and dimensions of the canyon walls, road, and setbacks. Next, a method is presented to correct the values of temperature changes obtained from previous urban climate models to values that would be obtained from canyon geometries that distinguish between road and setbacks (e.g. sidewalk, front yard). The new canyon model is used to scale the temperature changes obtained from a recent urban climate model that simulated the climatological impact of cool pavements on various California cities. The adjusted temperature changes are then combined with building energy simulations to investigate the effect of cool pavements on the cooling, heating, and lighting energy uses of buildings as well as the environmental impact related to these energy uses. Net (direct + indirect) conditioning (cooling + heating) energy savings and environmental savings from cool pavements were smaller in residential buildings than in commercial buildings. Additionally, residential buildings strongly dominate the building stock in all of the evaluated cities. Therefore, even though most cities yielded conditioning energy and environmental savings, they were small due to the minuscule savings from the residential buildings. When increasing the albedo by 0.20 of all public pavements in different California cities, Los Angeles was the city with the largest savings, yielding only 0.60% in Primary Energy Demand and 0.30% in Global Warming Potential (GWP). Some of the cities experienced even a small net penalty in GWP of up to 0.20%.
Odland, D; Davis, C
1982-08-01
Plain muffins, yellow cake, baked custard, apple pie, tuna casserole, frozen tuna casserole, cheese soufflé, and meat loaf were baked in preheated and non-preheated standard gas, continuous-clean gas, standard electric, and self-cleaning electric ovens. Products generally required 5 min. or less extra baking time when cooked in non-preheated rather than in preheated ovens. The variability in baking times often was less between preheated and non-preheated ovens than among oven types. Calculated energy consumption values showed that usually less energy was required to bake products in non-preheated than in preheated ovens; savings averaged about 10 percent. Few significant differences were found in physical measurements or eating quality either between preheated and non-preheated ovens or among oven types. Overall, for the products tested, findings confirmed that preheating the oven is not essential for good product quality and, therefore, is an unnecessary use of energy.
International Experience in Standards and Labeling Programs for Rice Cookers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Nan; Zheng, Nina
China has had an active program on energy efficiency standards for household appliances since the mid-1990s. Rice cooker is among the first to be subject to such mandatory regulation, since it is one of the most prevalent electric appliances in Chinese households. Since first introduced in 1989, the minimum energy efficiency standard for rice cookers has not been revised. Therefore, the potential for energy saving is considerable. Initial analysis from CNIS indicates that potential carbon savings is likely to reach 7.6 million tons of CO2 by the 10th year of the standard implementation. Since September 2007, CNIS has been workingmore » with various groups to develop the new standard for rice cookers. With The Energy Foundation's support, LBNL has assisted CNIS in the revision of the minimum energy efficiency standard for rice cookers that is expected to be effective in 2009. Specifically, work has been in the following areas: assistance in developing consumer survey on usage pattern of rice cookers, review of international standards, review of international test procedures, comparison of the international standards and test procedures, and assessment of technical options of reducing energy use. This report particularly summarizes the findings of reviewing international standards and technical options of reducing energy consumption. The report consists of an overview of rice cooker standards and labeling programs and testing procedures in Hong Kong, South Korea, Japan and Thailand, and Japan's case study in developing energy efficiency rice cooker technologies and rice cooker efficiency programs. The results from the analysis can be summarized as the follows: Hong Kong has a Voluntary Energy Efficiency Labeling scheme for electric rice cookers initiated in 2001, with revision implemented in 2007; South Korea has both MEPS and Mandatory Energy Efficiency Label targeting the same category of rice cookers as Hong Kong; Thailand's voluntary endorsement labeling program is similar to Hong Kong in program design but has 5 efficiency grades; Japan's program is distinct in its adoption of the 'Top Runner' approach, in which, the future efficiency standards is set based on the efficiency levels of the most efficient product in the current domestic market. Although the standards are voluntary, penalties can still be evoked if the average efficiency target is not met. Both Hong Kong and South Korea's tests involve pouring water into the inner pot equal to 80% of its rated volume; however, white rice is used as a load for its tests in Hong Kong whereas no rice is used for tests in South Korea. In Japan's case, water level specified by the manufactures is used and milled rice is used as a load only partially in the tests. Moreover, Japan does not conduct heat efficiency test but its energy consumption measurements tests are much more complex, with 4 different tests are conducted to determine the annual average energy consumption. Hong Kong and Thailand both set Minimum Allowable Heat Efficiency for different rated wattages. The energy efficiency requirements are identical except that the minimum heat efficiency in Thailand is 1 percentage point higher for all rated power categories. In South Korea, MEPS and label's energy efficiency grades are determined by the rice cooker's Rated Energy Efficiency for induction, non-induction, pressure, nonpressure rice cookers. Japan's target standard values are set for electromagnetic induction heating products and non-electromagnetic induction heating products by different size of rice cookers. Specific formulas are used by type and size depending on the mass of water evaporation of the rice cookers. Japan has been the leading country in technology development of various types of rice cookers, and developed concrete energy efficiency standards for rice cookers. However, as consumers in Japan emphasize the deliciousness of cooked rice over other factors, many types of models were developed to improve the taste of cooked rice. Nonetheless, the efficiency of electromagnetic induction heating (IH) rice cookers in warm mode has improved approximately 12 percent from 1993 to 2004 due to the 'low temperature warming method' developed by manufacturers. The Energy Conservation Center of Japan (IEEJ) releases energy saving products database on the web regularly, on which the energy saving performance of each product is listed and ranked. Energy saving in rice cookers mostly rest with insulation of the pot. Technology developed to improve the energy efficiency of the rice cookers includes providing vacuum layers on both side of the pot, using copper-plated materials, and double stainless layer lid that can be heated and steam can run in between the two layers to speed the heating process.« less
NASA Glenn Research Center Experience Using DOE Midwest Region Super ESPC
NASA Technical Reports Server (NTRS)
Zala, Laszlo F.
2000-01-01
The energy crisis of 1973 prompted the Federal Government and private industry to look into alternative methods to save energy. At the same time the constant reduction of operations and maintenance funds during the last 5 years forced Glenn Research Center (GRC) to look for alternative funding sources to meet the mandate to reduce energy consumption. The Super Energy Savings Performance Contract (ESPC) was chosen as a viable source of facility improvement funding that can create larger project scope and help replace aging, inefficient equipment. This paper describes Glenn's participation in the Department of Energy (DOE) Super ESPC program. This program provided Glenn cost savings in the performance of energy audits, preparation of documents, evaluation of proposals, and selection of energy service company (ESCO).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hale, E. T.; Macumber, D. L.; Long, N. L.
2008-09-01
This report provides recommendations that architects, designers, contractors, developers, owners, and lessees of grocery store buildings can use to achieve whole-building energy savings of at least 50% over ASHRAE Standard 90.1-2004.
ERIC Educational Resources Information Center
Kennedy, Mike
2000-01-01
Discusses how schools and universities can save energy and money by evaluating lighting systems and changing behaviors. Retrofitting older buildings with better lighting technology and use of natural light are examined. An example of an energy conservation education program to reduce energy waste is highlighted. (GR)
Energy Management: Money in the Bank.
ERIC Educational Resources Information Center
Have, Pete van der
2001-01-01
Discusses how the University of Utah developed a new chiller plant that could handle the existing and future loads of energy requirements while being totally financed via the implementation of energy saving retrofits, but not benefitting from the operations savings generated by their implementation. (GR)
The Energy Implications of Air-Side Fouling in Constant Air Volume HVAC Systems
NASA Astrophysics Data System (ADS)
Wilson, Eric J. H.
2011-12-01
This thesis examines the effect of air-side fouling on the energy consumption of constant air volume (CAV) heating, ventilating, and air conditioning (HVAC) systems in residential and small commercial buildings. There is a particular focus on evaluating the potential energy savings that may result from the remediation of such fouling from coils, filters, and other air system components. A computer model was constructed to simulate the behavior of a building and its duct system under various levels of fouling. The model was verified through laboratory and field testing and then used to run parametric simulations to examine the range of energy impacts for various climates and duct system characteristics. A sensitivity analysis was conducted to determine the impact of parameters like duct insulation, duct leakage, duct location, and duct design on savings potential. Duct system pressures, temperatures, and energy consumption for two houses were monitored for one month. The houses' duct systems, which were both in conditioned space, were given a full cleaning, and were then monitored for another month. The flow rates at the houses improved by 10% and 6%. The improvements were primarily due to installing a new filter, as both houses had only light coil fouling. The results indicate that there was negligible change in heating energy efficiency due to the system cleaning. The parametric simulation results are in agreement with the field experiment: for systems in all eight climates, with flowrates degraded by 20% or less, if ducts are located within the thermal zone, HVAC source energy savings from cleaning are negligible or even slightly negative. However, if ducts are outside the thermal zone, savings are in the 1 to 5% range. For systems with flowrates degraded by 40%, if ducts are within the thermal zone, savings from cleaning occurs only for air conditioning energy, up to 8% in climates like Miami, FL. If ducts are outside the thermal zone, savings occurs with both heating and cooling energy, and ranges from 7% in Los Angeles, CA to 13% in Fairbanks, AK. These results assume a leaky and uninsulated duct system. The potential for savings from cleaning decreases if duct insulation is in place or sealing has been performed. The potential for energy savings is directly related to the distribution system's thermal efficiency, with air conditioner performance also playing a minor role. Results for small commercial buildings with constant air volume HVAC systems and leaky and uninsulated duct systems span a wider range: from -12% in Miami, FL to 30% in Minneapolis, MN. However, for improved ducts or ducts in the conditioned space, small commercial HVAC source energy savings is always negative (down to -17%) for flowrates degradation in the 0--40% range. The sensitivity of these results to duct characteristics (location, leakage, and insulation) and the after-cleaning flowrate, as it varies from an ideal flowrate, was also evaluated. Energy savings can reach up to 80% for some scenarios where clean airflow is severely restricted down to 20% of ideal by poor duct layout or other obstructions not removable by cleaning. In addition, a simplified spreadsheet tool was developed for technicians to use in the field to estimate potential savings resulting from a system cleaning. Measuring the temperature rise across the furnace was found to give less uncertainty than measuring the pressure rise and assuming a fan curve. Despite the uncertainty, the tool can give a general idea of the range of savings possible under various conditions.
Development of new methodologies for evaluating the energy performance of new commercial buildings
NASA Astrophysics Data System (ADS)
Song, Suwon
The concept of Measurement and Verification (M&V) of a new building continues to become more important because efficient design alone is often not sufficient to deliver an efficient building. Simulation models that are calibrated to measured data can be used to evaluate the energy performance of new buildings if they are compared to energy baselines such as similar buildings, energy codes, and design standards. Unfortunately, there is a lack of detailed M&V methods and analysis methods to measure energy savings from new buildings that would have hypothetical energy baselines. Therefore, this study developed and demonstrated several new methodologies for evaluating the energy performance of new commercial buildings using a case-study building in Austin, Texas. First, three new M&V methods were developed to enhance the previous generic M&V framework for new buildings, including: (1) The development of a method to synthesize weather-normalized cooling energy use from a correlation of Motor Control Center (MCC) electricity use when chilled water use is unavailable, (2) The development of an improved method to analyze measured solar transmittance against incidence angle for sample glazing using different solar sensor types, including Eppley PSP and Li-Cor sensors, and (3) The development of an improved method to analyze chiller efficiency and operation at part-load conditions. Second, three new calibration methods were developed and analyzed, including: (1) A new percentile analysis added to the previous signature method for use with a DOE-2 calibration, (2) A new analysis to account for undocumented exhaust air in DOE-2 calibration, and (3) An analysis of the impact of synthesized direct normal solar radiation using the Erbs correlation on DOE-2 simulation. Third, an analysis of the actual energy savings compared to three different energy baselines was performed, including: (1) Energy Use Index (EUI) comparisons with sub-metered data, (2) New comparisons against Standards 90.1-1989 and 90.1-2001, and (3) A new evaluation of the performance of selected Energy Conservation Design Measures (ECDMs). Finally, potential energy savings were also simulated from selected improvements, including: minimum supply air flow, undocumented exhaust air, and daylighting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, Van D.; Munk, Jeffrey D.; Gehl, Anthony C.
The field study is planned to continue through the 2016 cooling season with the draft final project report due by September 30, 2016. This report provides a description of both installations and preliminary 2015 cooling and fall season performance results for the Knoxville site. For the August 18 through December 14 period, the Knoxville site GS-IHP provided 53.6% total source energy savings compared to a baseline electric RTU/heat pump and electric WH. Peak demand savings ranged from 33% to 59% per month. Energy cost savings of 53.1% have been achieved to date with more than half of that coming frommore » reduced demand charges. Data on installation and maintenance costs are being collected and will be combined with total test period energy savings data for a payback analysis to be included in the project final report. The GS-IHP also saved a significant amount of carbon emissions. The total emission savings for the Knoxville site for the August-December 2015 period were ~0.8 metric tons. If trading for carbon credits ever becomes a reality, additional cost savings would be realized.« less
Guide to Financing EnergySmart Schools
ERIC Educational Resources Information Center
US Department of Energy, 2010
2010-01-01
By making a commitment to high-performance schools, many school districts are discovering that smart energy choices can have lasting benefits for their students, their communities, and the environment. An energy-efficient school district with 4,000 students could save as much as $160,000 a year in energy costs. Over 10 years, those savings can…
Maximizing Energy Savings for Small Business Text Version | Buildings |
owners have a big opportunity to save money and energy, while cutting greenhouse gas emissions. Drawing have the money, nor time, to pursue something like that. Drawing of computer screen, showing NREL's energy and non-energy related benefits. Drawing of money, buildings, machinery, and furniture. Narrator
Portable+: A Ubiquitous And Smart Way Towards Comfortable Energy Savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, Milan; Singh, Amarjeet; Chandan, Vikas
An air conditioner (AC) consumes a significant proportion of the total household power consumption. Primarily used in developing countries, decentralised AC has an inbuilt thermostat to cool the room to a temperature, manually set by the users. However, residents are incapable of specifying their goal through these thermostats - maximise their comfort or save AC energy. State-of-the-art portable thermostats emulate AC remotes and assist occupants in remotely changing the thermostat temperature, through their smartphones. We propose extending such thermostats to portable+ by adding a Comfort-Energy Trade-off (CET) knob, realised through an optimisation framework to allow users to balance their comfortmore » and the savings without worrying about the right set temperature. Analysis based on real data, collected from a controlled experiment (across two rooms for two weeks) and an in-situ deployment (across five rooms for three months), indicates that portable+ thermostats can reduce residents’ discomfort by 23% (CET selection for maximal comfort) and save 26% energy when CET is set for maximising savings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strategic Priorities and Impact Analysis Team, Office of Strategic Programs
This fact sheet "New Haven, Connecticut: Targeting Low-Income Household Energy Savings" explains how the City of New Haven used data from the U.S. Department of Energy's Cities Leading through Energy Analysis and Planning (Cities-LEAP) and the State and Local Energy Data (SLED) programs to inform its city energy planning. It is one of ten fact sheets in the "City Energy: From Data to Decisions" series.
77 FR 23373 - Small Business Investment Companies-Energy Saving Qualified Investments
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-19
... Debenture usage, number of Small Businesses financed, resulting breakthroughs in technology, comparative studies quantifying energy savings, and performance of Small Businesses financed. While SBA is concerned...
Reducing EnergyPlus Run Time For Code Compliance Tools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Athalye, Rahul A.; Gowri, Krishnan; Schultz, Robert W.
2014-09-12
Integration of the EnergyPlus ™ simulation engine into performance-based code compliance software raises a concern about simulation run time, which impacts timely feedback of compliance results to the user. EnergyPlus annual simulations for proposed and code baseline building models, and mechanical equipment sizing result in simulation run times beyond acceptable limits. This paper presents a study that compares the results of a shortened simulation time period using 4 weeks of hourly weather data (one per quarter), to an annual simulation using full 52 weeks of hourly weather data. Three representative building types based on DOE Prototype Building Models and threemore » climate zones were used for determining the validity of using a shortened simulation run period. Further sensitivity analysis and run time comparisons were made to evaluate the robustness and run time savings of using this approach. The results of this analysis show that the shortened simulation run period provides compliance index calculations within 1% of those predicted using annual simulation results, and typically saves about 75% of simulation run time.« less
Liu, Huacai; Yin, Xiuli; Wu, Chuangzhi
2014-01-01
There has been a rapid growth in using agricultural residues as an energy source to generate electricity in China. Biomass power generation (BPG) systems may vary significantly in technology, scale, and feedstock and consequently in their performances. A comparative evaluation of five typical BPG systems has been conducted in this study through a hybrid life cycle inventory (LCI) approach. Results show that requirements of fossil energy savings, and greenhouse gas (GHG) emission reductions, as well as emission reductions of SO2 and NOx, can be best met by the BPG systems. The cofiring systems were found to behave better than the biomass-only fired system and the biomass gasification systems in terms of energy savings and GHG emission reductions. Comparing with results of conventional process-base LCI, an important aspect to note is the significant contribution of infrastructure, equipment, and maintenance of the plant, which require the input of various types of materials, fuels, services, and the consequent GHG emissions. The results demonstrate characteristics and differences of BPG systems and help identify critical opportunities for biomass power development in China. PMID:25383383
Liu, Huacai; Yin, Xiuli; Wu, Chuangzhi
2014-01-01
There has been a rapid growth in using agricultural residues as an energy source to generate electricity in China. Biomass power generation (BPG) systems may vary significantly in technology, scale, and feedstock and consequently in their performances. A comparative evaluation of five typical BPG systems has been conducted in this study through a hybrid life cycle inventory (LCI) approach. Results show that requirements of fossil energy savings, and greenhouse gas (GHG) emission reductions, as well as emission reductions of SO2 and NOx, can be best met by the BPG systems. The cofiring systems were found to behave better than the biomass-only fired system and the biomass gasification systems in terms of energy savings and GHG emission reductions. Comparing with results of conventional process-base LCI, an important aspect to note is the significant contribution of infrastructure, equipment, and maintenance of the plant, which require the input of various types of materials, fuels, services, and the consequent GHG emissions. The results demonstrate characteristics and differences of BPG systems and help identify critical opportunities for biomass power development in China.
Approach to the Lighting Energy Savings in Japan for Global Climate Change Prevention
NASA Astrophysics Data System (ADS)
Hanada, Teizo
This report was presented as an invited speech at “the First Lighting Symposium of China, Japan and Korea” held in Beijing on October 24, 2008. The reporter has introduced JELMA's proposal for energy saving in lighting, and explained purpose of their activities. Latest activities for replacing incandescent lamps to CFLi and its recent results are also reported. Japanese next big target for lighting energy saving is to replace the conventional fluorescent lamps to Hf-FLs.
Design of electric vehicle charging station based on wind and solar complementary power supply
NASA Astrophysics Data System (ADS)
Wang, Li
2018-05-01
Electric vehicles have become a major trend in the development of the automobile industry. Green energy saving is an important feature of their development. At the same time, the related charging facilities construction is also critical. If we improve the charging measures to adapt to its green energy-saving features, it will be to a greater extent to promote its further development. This article will propose a highly efficient green energy-saving charging station designed for the electric vehicles.
A simple tool for estimating city-wide annual electrical energy savings from cooler surfaces
Pomerantz, Melvin; Rosado, Pablo J.; Levinson, Ronnen
2015-07-26
We present a simple method to estimate the maximum possible energy saving that might be achieved by increasing the albedo of surfaces in a large city. We restrict this to the "indirect effect", the cooling of outside air that lessens the demand for air conditioning (AC). Given the power demand of the electric utilities and data about the city, we can use a single linear equation to estimate the maximum saving. For example, the result for an albedo change of 0.2 of pavements in a typical warm city in California, such as Sacramento, is that the saving is less thanmore » about 2 kWh per m 2 per year. This may help decision makers choose which heat island mitigation techniques are economical from an energy-saving perspective.« less
Sensor Suitcase: Portable System for Increasing Building Energy Efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
PNNL's Sensor Suitcase does an energy assessment of small buildings, enabling building owners to see which low-cost, energy-saving modifications would give them the best payoff. Implementing the recommended changes typically means 10% energy cost savings per small building. No other product provides such easy-to-use, expert-guided capabilities, and at half the cost of a typical energy assessment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindberg, James
The America Saves! Energizing Main Street Small Businesses project engaged the 1,200-member National Main Street Center (NMSC) network of downtown organizations and other local, regional, and national partners to test a methodology for sharing customized energy efficiency information with owners of commercial buildings smaller than 50,000 square feet. Led by the National Trust for Historic Preservation’s Preservation Green Lab, the project marshalled local staff and volunteers to gather voluntarily-disclosed energy use information from participating businesses. This information was analyzed using a remote auditing tool (validated by the National Renewable Energy Lab) to assess energy savings opportunities and design retrofit strategiesmore » targeting seven building types (food service and sales, attached mixed-use, strip mall, retail, office, lodging, and schools). The original project design contemplated extensive leveraging of the Green Button protocol for sharing annualized utility data at a district scale. Due the lack of adoption of Green Button, the project partners developed customized approaches to data collection in each of twelve pilot communities. The project team encountered considerable challenges in gathering standardized annual utility data from local partners. After overcoming these issues, the data was uploaded to a data storehouse. Over 450 properties were benchmarked and the remote auditing tool was tested using full building profiles and utility records for more than 100 commercial properties in three of the pilot communities. The audit tool demonstrated potential for quickly capturing, analyzing, and communicating energy efficiency opportunities in small commercial buildings. However, the project team found that the unique physical characteristics and use patterns (partial vacancy, periodic intensive uses) of small commercial buildings required more trouble-shooting and data correction than was anticipated. In addition, the project revealed that remote technology alone (such as audits) is not sufficient to convince most owners of commercial buildings or businesses to invest in energy efficiency. Additional, one-on-one personal communication is critical. A combination of technology and well-planned direct contact is likely to produce the highest rate of energy efficiency implementation in the small commercial building market sector. Note that only two of the three planned phases of this project were completed. As a result, research and testing were not fully implemented and thus all results and conclusions from the America Saves! Energizing Main Street Small Businesses project should be considered preliminary. In addition to the National Main Street Center, local organizations, and regional utilities, the America Saves! project partners included the National Renewable Energy Laboratory, Energy Center of Wisconsin (Seventh Wave), Lend Lease, Building Energy, and Energy RM.« less
Vacuum Pump System Optimization Saves Energy at a Dairy Farm
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
In 1998, S&S Dairy optimized the vacuum pumping system at their dairy farm in Modesto, California. In an effort to reduce energy costs, S&S Dairy evaluated their vacuum pumping system to determine if efficiency gains and energy savings were possible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2011-02-01
Researchers at the National Renewable Energy Laboratory (NREL) have developed two technical reports that provide recommendations to help designers and operators of large office buildings and hospitals achieve at least a 50% energy savings using existing technology.
Energy and Cost Savings of Retro-Commissioning and Retrofit Measures for Large Office Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Weimin; Zhang, Jian; Moser, Dave
2012-08-03
This paper evaluates the energy and cost savings of seven retro-commissioning measures and 29 retrofit measures applicable to most large office buildings. The baseline model is for a hypothetical building with characteristics of large office buildings constructed before 1980. Each retro-commissioning measure is evaluated against the original baseline in terms of its potential of energy and cost savings while each retrofit measure is evaluated against the commissioned building. All measures are evaluated in five locations (Miami, Las Vegas, Seattle, Chicago and Duluth) to understand the impact of weather conditions on energy and cost savings. The results show that implementation ofmore » the seven operation and maintenance measures as part of a retro-commissioning process can yield an average of about 22% of energy use reduction and 14% of energy cost reduction. Widening zone temperature deadband, lowering VAV terminal minimum air flow set points and lighting upgrades are effective retrofit measures to be considered.« less
A novel energy recovery system for parallel hybrid hydraulic excavator.
Li, Wei; Cao, Baoyu; Zhu, Zhencai; Chen, Guoan
2014-01-01
Hydraulic excavator energy saving is important to relieve source shortage and protect environment. This paper mainly discusses the energy saving for the hybrid hydraulic excavator. By analyzing the excess energy of three hydraulic cylinders in the conventional hydraulic excavator, a new boom potential energy recovery system is proposed. The mathematical models of the main components including boom cylinder, hydraulic motor, and hydraulic accumulator are built. The natural frequency of the proposed energy recovery system is calculated based on the mathematical models. Meanwhile, the simulation models of the proposed system and a conventional energy recovery system are built by AMESim software. The results show that the proposed system is more effective than the conventional energy saving system. At last, the main components of the proposed energy recovery system including accumulator and hydraulic motor are analyzed for improving the energy recovery efficiency. The measures to improve the energy recovery efficiency of the proposed system are presented.
A Novel Energy Recovery System for Parallel Hybrid Hydraulic Excavator
Li, Wei; Cao, Baoyu; Zhu, Zhencai; Chen, Guoan
2014-01-01
Hydraulic excavator energy saving is important to relieve source shortage and protect environment. This paper mainly discusses the energy saving for the hybrid hydraulic excavator. By analyzing the excess energy of three hydraulic cylinders in the conventional hydraulic excavator, a new boom potential energy recovery system is proposed. The mathematical models of the main components including boom cylinder, hydraulic motor, and hydraulic accumulator are built. The natural frequency of the proposed energy recovery system is calculated based on the mathematical models. Meanwhile, the simulation models of the proposed system and a conventional energy recovery system are built by AMESim software. The results show that the proposed system is more effective than the conventional energy saving system. At last, the main components of the proposed energy recovery system including accumulator and hydraulic motor are analyzed for improving the energy recovery efficiency. The measures to improve the energy recovery efficiency of the proposed system are presented. PMID:25405215
Up Close and Personal: The Value of Feedback in Implementing an Individual Energy-Saving Adaptation
ERIC Educational Resources Information Center
Pollard, Carol Elaine
2016-01-01
Purpose: The purpose of this research is to explore the drivers of computer-related sustainability behavior at a medium-sized US university and the extent to which an inexpensive energy-saving device installed on 146 administrator, faculty and general staff workstations achieved significant savings in kWh, CO[subscript 2] kg and dollars.…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dagle, J.E.
1992-09-01
The Pacific Northwest Laboratory identified energy savings potential of automatic equipment-room lighting controls, which was demonstrated by the field experiment described in this report. Occupancy sensor applications have gained popularity in recent years due to improved technology that enhances reliability and reduces cost. Automatic lighting control using occupancy sensors has been accepted as an energy-conservation measure because it reduces wasted lighting. This study focused on lighting control for equipment rooms, which have inherent conditions ideal for automatic lighting control, i.e., an area which is seldom occupied, multiple users of the area who would not know if others are in themore » room when they leave, and high lighting energy intensity in the area. Two rooms were selected for this study: a small equipment room in the basement of the 337 Building, and a large equipment area in the upper level of the 329 Building. The rooms were selected to demonstrate the various degrees of complexity which may be encountered in equipment rooms throughout the Hanford Site. The 337 Building equipment-room test case demonstrated a 97% reduction in lighting energy consumption, with an annual energy savings of $184. Including lamp-replacement savings, a total savings of $306 per year is offset by an initial installation cost of $1,100. The installation demonstrates a positive net present value of $2,858 when the lamp-replacement costs are included in a life-cycle analysis. This also corresponds to a 4.0-year payback period. The 329 Building equipment-room installation resulted in a 92% reduction in lighting energy consumption. This corresponds to annual energy savings of $1,372, and a total annual savings of $2,104 per year including lamp-replacement savings. The life-cycle cost analysis shows a net present value of $15,855, with a 5.8-year payback period.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Office of Strategic Programs, Strategic Priorities and Impact Analysis Team
This fact sheet "Columbia, Missouri: Using Energy Data to Reduce Emissions and Achieve Low-Income Household Energy Savings" explains how the City of Columbia used data from the U.S. Department of Energy's Cities Leading through Energy Analysis and Planning (Cities-LEAP) and the State and Local Energy Data (SLED) programs to inform its city energy planning. It is one of ten fact sheets in the "City Energy: From Data to Decisions" series.
Modernization of Electric Grid, Save Money On June 7, 2013, President Obama issued a Presidential Memorandum (PM reliable, save consumers money on their energy bills, and support homegrown American clean energy jobs and
Window performance and building energy use: Some technical options for increasing energy efficiency
NASA Astrophysics Data System (ADS)
Selkowitz, Stephen
1985-11-01
Window system design and operation has a major impact on energy use in buildings as well as on occupants' thermal and visual comfort. Window performance will be a function of optical and thermal properties, window management strategies, climate and orientation, and building type and occupancy. In residences, heat loss control is a primary concern, followed by sun control in more southerly climates. In commercial buildings, the daylight provided by windows may be the major energy benefits but solar gain must be controlled so that increased cooling loads do not exceed daylighting savings. Reductions in peak electrical demand and HVAC system size may also be possible in well-designed daylighted buildings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1984-04-18
The purpose of this study is to determine the amount of energy being used, the cost of this energy, and to recommend projects that will reduce energy consumption for Buildings 101, 104, 107, 114, 116, 118, 119, 120, 122, 125 and 138, located in the Forest Glen Complex, which is part of the Walter Reed Army Medical Center (WRAMC). Executive Order No. 12003, 20 July 1977, established energy conservation goals for existing Federal facilities requiring a reduction of 20% in the average energy use in FY 85 from the average annual energy requirements in FY 75. The Energy Conservation Investmentmore » Program (ECIP) is a Military Construction funded program for retrofitting existing DOD facilities to make them more energy efficient and thus providing substantial savings in utility costs. Each project is assessed in terms of source energy saved, the value of the energy and the capital and operating costs of the changes. The ECIP guidance provides two criteria for evaluating energy saving opportunities. These are an energy/cost ratio (E/C) and a benefit/cost ratio (B/C). For FY 84 the E/C ratio must be 13 or more with a B/C greater than one. Beginning with FY 85, ECIP projects will be prioritized on the basis of the greatest life cycle payback as determined by the savings to investment ratio (SIR). Overall projects and discrete portions of projects must be life cycle cost effective (SIR equal to or greater than 1). All energy savings projected in FY 85 shall be based on full occupancy of the buildings in the study.« less
Building an Energy-efficient Uplink and Downlink Delay Aware TDM-PON System
NASA Astrophysics Data System (ADS)
Newaz, S. H. Shah; Jang, Min Seok; Alaelddin, Fuad Yousif Mohammed; Lee, Gyu Myoung; Choi, Jun Kyun
2016-05-01
With the increasing concern over the energy expenditure due to rapid ICT expansion and growth of Internet traffic volume, there is a growing trend towards developing energy-efficient ICT solutions. Passive Optical Network (PON), which is regarded as a key enabler to facilitate high speed broadband connection to individual subscribers, is considered as one of the energy-efficient access network technologies. However, an immense amount of research effort can be noticed in academia and industries to make PON more energy-efficient. In this paper, we aim at improving energy saving performance of Time Division Multiplexing (TDM)-PON, which is the most widely deployed PON technology throughout the world. A commonly used approach to make TDM-PON energy-efficient is to use sleep mode in Optical Network Units (ONUs), which are the customer premises equipment of a TDM-PON system. However, there is a strong trade-off relationship between traffic delay performance of an ONU and its energy saving (the longer the sleep interval length of an ONU, the lower its energy consumption, but the higher the traffic delay, and vice versa). In this paper, we propose an Energy-efficient Uplink and Downlink Delay Aware (EUDDA) scheme for TDM-PON system. The prime object of EUDDA is to meet both downlink and uplink traffic delay requirement while maximizing energy saving performance of ONUs as much as possible. In EUDDA, traffic delay requirement is given more priority over energy saving. Even so, it still can improve energy saving of ONUs noticeably. We evaluate performance of EUDDA in front of two existing solutions in terms of traffic delay, jitter, and ONU energy consumption. The performance results show that EUDDA significantly outperforms the other existing solutions.
Greening the Bottom Line, 2012
ERIC Educational Resources Information Center
Flynn, Emily
2012-01-01
With buildings consuming almost half (49 percent) of all energy used in the United States, and three quarters of all electricity, there is a compelling need for investment in energy efficiency upgrades. These energy saving improvements "represent a significant opportunity to save money, reduce climate impact and generate jobs," according…
Electronic Dimmable Ballasts for High-Intensity Discharge Sodium Vapor and Metal Halide Lamps
NASA Technical Reports Server (NTRS)
Boulanger, Richard
2002-01-01
Two types of high-intensity discharge lamps were tested using dimmable ballasts. The main purpose for evaluating this lighting system was to determine its efficacy for saving power. Whereas previous variable level lighting systems for HID lamps in Advanced Life Support applications were adjustable in two or three steps using capacitive switching, this system allows for continuously adjustable lamp output. This type of lighting system when used as part of an Advanced Life Support biomass production system would provide only the amount of light energy a crop needed at any particular point in its growth cycle. Since most of the equivalent system mass in an ALS system is from the light energy required to grow the crops, controlling that light energy dynamically over a continuous range of operation would dramatically reduce the power consumption and reduce system mass.
Window Treatment Phase I and Other Energy II Conservation Measures.
ERIC Educational Resources Information Center
Donohue, Philip E.
Six different energy-saving treatments for large window areas were tested by Tompkins-Cortland Community College (TCCC) to coordinate energy saving with building design. The TCCC building has an open space design with 33,000 square feet of external glass and other features causing heating problems and high energy costs. Phase I of the…
Energy Efficiency Team Helping Delaware Towns Find Savings
The wastewater treatment plant in Selbyville, Delaware, is benefitting from an EPA-Delaware partnership designed to help water and wastewater facilities save energy and money while cutting pollution that contributes to climate change.
Development of an automated energy audit protocol for office buildings
NASA Astrophysics Data System (ADS)
Deb, Chirag
This study aims to enhance the building energy audit process, and bring about reduction in time and cost requirements in the conduction of a full physical audit. For this, a total of 5 Energy Service Companies in Singapore have collaborated and provided energy audit reports for 62 office buildings. Several statistical techniques are adopted to analyse these reports. These techniques comprise cluster analysis and development of prediction models to predict energy savings for buildings. The cluster analysis shows that there are 3 clusters of buildings experiencing different levels of energy savings. To understand the effect of building variables on the change in EUI, a robust iterative process for selecting the appropriate variables is developed. The results show that the 4 variables of GFA, non-air-conditioning energy consumption, average chiller plant efficiency and installed capacity of chillers should be taken for clustering. This analysis is extended to the development of prediction models using linear regression and artificial neural networks (ANN). An exhaustive variable selection algorithm is developed to select the input variables for the two energy saving prediction models. The results show that the ANN prediction model can predict the energy saving potential of a given building with an accuracy of +/-14.8%.
Impacts of Commercial Building Controls on Energy Savings and Peak Load Reduction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernandez, Nicholas E.P.; Katipamula, Srinivas; Wang, Weimin
Commercial buildings in the United States use about 18 Quadrillion British thermal units (Quads) of primary energy annually . Studies have shown that as much as 30% of building energy consumption can be avoided by using more accurate sensing, using existing controls better, and deploying advanced controls; hence, the motivation for the work described in this report. Studies also have shown that 10% to 20% of the commercial building peak load can be temporarily managed/curtailed to provide grid services. Although many studies have indicated significant potential for reducing the energy consumption in commercial buildings, very few have documented the actualmore » savings. The studies that did so only provided savings at the whole building level, which makes it difficult to assess the savings potential of each individual measure deployed.« less
Skylight energy performance and design optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arasteh, D.; Johnson, R.; Selkowitz, S.
1984-02-01
Proper skylight utilization can significantly lower energy requirements and peak electrical loads for space conditioning and lighting in commercial buildings. In this study we systematically explore the energy effects of skylight systems in a prototypical office building and examine the savings from daylighting. The DOE-2.1B energy analysis computer program with its newly incorporated daylighting algorithms was used to generate more than 2000 parametric simulations for seven US climates. The parameters varied include skylight-to-roof ratio, shading coefficient, visible transmittance, skylight well light loss, electric lighting power density, roof heat transfer coefficient, and type of electric lighting control. For specific climates wemore » identify roof/skylight characteristics that minimize total energy or peak electrical load requirements.« less
Energy performance standards for new buildings: Economic analysis
NASA Astrophysics Data System (ADS)
1980-01-01
The major economic impacts of the implementations of the standards on affected groups were assessed and the effectiveness of the standards as an investment in energy conservation was evaluated. The methodology used to evaluate the standards for the various building types and perspectives is described. The net economic effect of changes in building cost and energy use are discussed for three categories of buildings: single family residential, commercial and multifamily residential, and mobile homes. Forecasts of energy savings and national costs and benefits both with and without implementation of the standards are presented. The effects of changes in energy consumption and construction of new buildings on the national economy, including such factors as national income, investment, employment, and balance of trade are assessed.
Analysis of optimal design of low temperature economizer
NASA Astrophysics Data System (ADS)
Song, J. H.; Wang, S.
2017-11-01
This paper has studied the Off-design characteristic of low temperature economizer system based on thermodynamics analysis. Based on the data from one 1000 MW coal-fired unit, two modes of operation are contrasted and analyzed. One is to fix exhaust gas temperature and the other one is to take into account both of the average temperature difference and the exhaust gas temperature. Meanwhile, the cause of energy saving effect change is explored. Result shows that: in mode 1, the amount of decrease in coal consumption reduces from 1.11 g/kWh (under full load) to 0.54 g/kWh (under half load), and in mode 2, when the load decreases from 90% to 50%, the decrease in coal consumption reduces from 1.29 g/kWh to 0.84 g/kWh. From the result, under high load, the energy saving effect is superior, and under lower work load, energy saving effect declines rapidly when load is reduced. When load changes, the temperature difference of heat transfer, gas flow, the flue gas heat rejection and the waste heat recovery change. The energy saving effect corresponding changes result in that the energy saving effect under high load is superior and more stable. However, rational adjustment to the temperature of outlet gas can alleviate the decline of the energy saving effect under low load. The result provides theoretical analysis data for the optimal design and operation of low temperature economizer system of power plant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, Yasin; Khare, Vaibhav Rai; Mathur, Jyotirmay
The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building usingmore » a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. Lastly, the energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.« less
The Conservation Nexus: Valuing Interdependent Water and Energy Savings in Phoenix, Arizona
NASA Astrophysics Data System (ADS)
Chester, M.; Bartos, M.
2013-12-01
Energy and water resources are intrinsically linked, yet they are managed separately--even in the water-scarce American southwest. This study develops a spatially-explicit model of water-energy interdependencies in Arizona, and assesses the potential for co-beneficial conservation programs. Arizona consumes 2.8% of its water demand for thermoelectric power and 8% of its electricity demand for water infrastructure--roughly twice the national average. The interdependent benefits of investments in 7 conservation strategies are assessed. Deployment of irrigation retrofits and new reclaimed water facilities dominate potential water savings, while residential and commercial HVAC improvements dominate energy savings. Water conservation policies have the potential to reduce statewide electricity demand by 1.0-2.9%, satisfying 5-14% of mandated energy-efficiency goals. Likewise, adoption of energy-efficiency measures and renewable generation portfolios can reduce non-agricultural water demand by 2.0-2.6%. These co-benefits of conservation investments are typically not included in conservation plans or benefit-cost analyses. Residential water conservation measures produce significant water and energy savings, but are generally not cost-effective at current water prices. An evaluation of the true cost of water in Arizona would allow future water and energy savings to be compared objectively, and would help policymakers allocate scarce resources to the highest-value conservation measures. Water Transfers between Water Cycle Components in Arizona in 2008 Cumulative embedded energy in water cycle components in Arizona in 2008
Data on European non-residential buildings.
D'Agostino, Delia; Cuniberti, Barbara; Bertoldi, Paolo
2017-10-01
This data article relates to the research paper Energy consumption and efficiency technology measures in European non-residential buildings (D'Agostino et al., 2017) [1]. The reported data have been collected in the framework of the Green Building Programme that ran from 2006 to 2014. The project has encouraged the adoption of efficiency measures to boost energy savings in European non-residential buildings. Data focus on the one-thousand buildings that joined the Programme allowing to save around 985 GWh/year. The main requirement to join the Programme was the reduction of at least 25% primary energy consumption in a new or retrofitted building. Energy consumption before and after the renovation are provided for retrofitted buildings while, in new constructions, a building had to be designed using at least 25% less energy than requested by the country's building codes. The following data are linked within this article: energy consumption, absolute and relative savings related to primary energy, saving percentages, implemented efficiency measures and renewables. Further information is given about each building in relation to geometry, envelope, materials, lighting and systems.
Energy-saving framework for passive optical networks with ONU sleep/doze mode.
Van, Dung Pham; Valcarenghi, Luca; Dias, Maluge Pubuduni Imali; Kondepu, Koteswararao; Castoldi, Piero; Wong, Elaine
2015-02-09
This paper proposes an energy-saving passive optical network framework (ESPON) that aims to incorporate optical network unit (ONU) sleep/doze mode into dynamic bandwidth allocation (DBA) algorithms to reduce ONU energy consumption. In the ESPON, the optical line terminal (OLT) schedules both downstream (DS) and upstream (US) transmissions in the same slot in an online and dynamic fashion whereas the ONU enters sleep mode outside the slot. The ONU sleep time is maximized based on both DS and US traffic. Moreover, during the slot, the ONU might enter doze mode when only its transmitter is idle to further improve energy efficiency. The scheduling order of data transmission, control message exchange, sleep period, and doze period defines an energy-efficient scheme under the ESPON. Three schemes are designed and evaluated in an extensive FPGA-based evaluation. Results show that whilst all the schemes significantly save ONU energy for different evaluation scenarios, the scheduling order has great impact on their performance. In addition, the ESPON allows for a scheduling order that saves ONU energy independently of the network reach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konopacki, S.; Akbari, H.; Gartland, L.
The U.S. Environmental Protection Agency (EPA) sponsored this project to estimate potential energy and monetary savings resulting from the implementation of light-colored roofs on residential and commercial buildings in major U.S. metropolitan areas. Light-colored roofs reflect more sunlight than dark roofs, so they keep buildings cooler and reduce air-conditioning demand. Typically, rooftops in the United States are dark, and thus there is a potential for saving energy and money by changing to reflective roofs. Naturally, the expected savings are higher in southern, sunny, and cloudless climates. In this study, we make quantitative estimates of reduction in peak power demand andmore » annual cooling electricity use that would result from increasing the reflectivity of the roofs. Since light-colored roofs also reflect heat in the winter, the estimates of annual electricity savings are a net value corrected for the increased wintertime energy use. Savings estimates only include direct reduction in building energy use and do not account for the indirect benefit that would also occur from the reduction in ambient temperature, i.e. a reduction in the heat island effect. This analysis is based on simulations of building energy use, using the DOE-2 building energy simulation program. Our methodology starts with specifying 11 prototypical buildings: single-family residential (old and new), office (old and new), retail store (old and new), school (primary and secondary), health (hospital and nursing home), and grocery store. Most prototypes are simulated with two heating systems: gas furnace and heat pumps. We then perform DOE-2 simulations of the prototypical buildings, with light and dark roofs, in a variety of climates and obtain estimates of the energy use for air conditioning and heating.« less
Aggressive Strategies for Residential Energy and Carbon Savings by 2025
NASA Astrophysics Data System (ADS)
Ling, F. H.; Kammen, D. M.
2004-12-01
Energy efficiency technologies and practices have long been recognized as a low-cost, often least cost, option that can be deployed widely throughout the economy (Steve Nadel, 2002; Donald A. Hanson and John A. Laitner, 2003). We are engaged in a review of technology-based energy savings options throughout the U. S. economy with a joint focus on both immediate savings opportunities and long-term strategies for accelerating the innovation process and pipeline. For the near term, we developed scenarios based on available 'off the shelf' technologies and practices for achieving minimum energy consumption in lighting, standby power in electronics, and miscellaneous end-uses in the U.S. residential sector. In the business-as-usual (BAU) case, energy consumption continues to grow despite innovations at a current rate of 1.7 percent/year (Laitner, 2004). Nevertheless, the need for developing new energy supplies can be mitigated through the use of 'best current technologies' as the industry norm in 2025. Figure 1 (see URL below) shows this reduction in energy consumption and greenhouse gas emissions. The BAU model corresponds to the current rate of 'decarbonization' in the overall U.S. economy (Energy Information Administration, 2004). Over a twenty-year period, about 2 billion metric tons of carbon dioxide and 30 quads of primary fuel could be saved through the introduction of "best current technology" with the greatest reductions in the area of lighting technologies. In 2025, 1.5 quads of primary energy is saved with the breakdown in end-use electricity saved as follows: 113 TWh (0.39 quads), 70.8 TWh (0.24 quads), and 62 TWh (0.21 quads) for residential lighting, appliance standards, and standby power respectively. In addition, there is empirical evidence from specific technology sectors, from statewide programs in California, as well as on theoretical grounds (Laitner, 2004) that innovation and decarbonization rates of 3 to 5 percent/year have at times been, and could again be achieved. While such high rates of innovation do not usually sustain themselves for more than a few years, innovation rates higher than the current 1.7 percent/year are also explored in this study. Acknowledgement: Alliance to Save Energy (ASE) and Energy Foundation References: Energy Information Administration. "Annual Energy Outlook 2004." Washington, DC: U.S. Department of Energy, 2004. Hanson, Donald A. and Laitner, John A. "Skip". "An Integrated Analysis of Policies That Increase Investments in Advanced Energy-Efficient/Low-Carbon Technologies." Energy Economics, 2003. Laitner, J. A. "How far energy efficiency." 2004. Nadel, Steve. "Appliance and Equipment Efficiency Standards." Annual Reviews, 2002.
Tendon elasticity and muscle function.
Alexander, R McNeill
2002-12-01
Vertebrate animals exploit the elastic properties of their tendons in several different ways. Firstly, metabolic energy can be saved in locomotion if tendons stretch and then recoil, storing and returning elastic strain energy, as the animal loses and regains kinetic energy. Leg tendons save energy in this way when birds and mammals run, and an aponeurosis in the back is also important in galloping mammals. Tendons may have similar energy-saving roles in other modes of locomotion, for example in cetacean swimming. Secondly, tendons can recoil elastically much faster than muscles can shorten, enabling animals to jump further than they otherwise could. Thirdly, tendon elasticity affects the control of muscles, enhancing force control at the expense of position control.
Simulation of Trolleybus Traction Induction Drive With Supercapacitor Energy Storage System
NASA Astrophysics Data System (ADS)
Brazis, V.; Latkovskis, L.; Grigans, L.
2010-01-01
The article considers the possibilities of saving the regenerative braking energy in Škoda 24Tr type trolleybuses by installing the onboard supercapacitor energy storage system (ESS) and improving its performance with automated switching to the autonomous traction mode. Proposed is an ESS control system with constant DC bus voltage in the supercapacitor charging mode and supercapacitor current proportional to the AC drive current in the discharging mode. The authors investigate stability of the trolleybus ESS control system operating together with AC traction drive in various overhead voltage failure modes. The co-simulation of ESS operation was done by Matlab/Simulink AC drive and PSIM ESS continuous models.
Energy monitoring system based on human activity in the workplace
NASA Astrophysics Data System (ADS)
Mustafa, Nur Hanim; Husain, Mohd Nor; Aziz, Mohamad Zoinol Abidin Abdul; Othman, Mohd Azlishah; Malek, Fareq
2015-05-01
Human behaviors always related to day routine activities in a smart house directly give the significant factor to manage energy usage in human life. An Addition that, the factor will contribute to the best efficiency of the system. This paper will focus on the monitoring efficiency based on duration time in office hours around 8am until 5pm which depend on human behavior at working place. Besides that, the correlation coefficient method is used to show the relation between energy consumption and energy saving based on the total hours of time energy spent. In future, the percentages of energy monitoring system usage will be increase to manage energy saving based on human behaviors. This scenario will help to see the human activity in the workplace in order to get the energy saving and support world green environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akbari, Hashem; Xu, Tengfang; Taha, Haider
Cool roofs, cool pavements, and urban vegetation reduce energy use in buildings, lower local air pollutant concentrations, and decrease greenhouse gas emissions from urban areas. This report summarizes the results of a detailed monitoring project in India and related simulations of meteorology and air quality in three developing countries. The field results quantified direct energy savings from installation of cool roofs on individual commercial buildings. The measured annual energy savings potential from roof-whitening of previously black roofs ranged from 20-22 kWh/m2 of roof area, corresponding to an air-conditioning energy use reduction of 14-26% in commercial buildings. The study estimated thatmore » typical annual savings of 13-14 kWh/m2 of roof area could be achieved by applying white coating to uncoated concrete roofs on commercial buildings in the Metropolitan Hyderabad region, corresponding to cooling energy savings of 10-19%. With the assumption of an annual increase of 100,000 square meters of new roof construction for the next 10 years in the Metropolitan Hyderabad region, the annual cooling energy savings due to whitening concrete roof would be 13-14 GWh of electricity in year ten alone, with cumulative 10-year cooling energy savings of 73-79 GWh for the region. The estimated savings for the entire country would be at least 10 times the savings in Hyderabad, i.e., more than 730-790 GWh. We estimated that annual direct CO2 reduction associated with reduced energy use would be 11-12 kg CO2/m2 of flat concrete roof area whitened, and the cumulative 10-year CO2 reduction would be approximately 0.60-0.65 million tons in India. With the price of electricity estimated at seven Rupees per kWh, the annual electricity savings on air-conditioning would be approximately 93-101 Rupees per m2 of roof. This would translate into annual national savings of approximately one billion Rupees in year ten, and cumulative 10-year savings of over five billion Rupees for cooling energy in India. Meteorological simulations in this study indicated that a reduction of 2C in air temperature in the Hyderabad area would be likely if a combination of increased surface albedo and vegetative cover are used as urban heat-island control strategies. In addition, air-temperature reductions on the order of 2.5-3.5C could be achieved if moderate and aggressive heat-island mitigation measures are adopted, respectively. A large-scale deployment of mitigation measures can bring additional indirect benefit to the urban area. For example, cooling outside air can improve the efficiency of cooling systems, reduce smog and greenhouse gas (GHG) emissions, and indirectly reduce pollution from power plants - all improving environmental health quality. This study has demonstrated the effectiveness of cool-roof technology as one of the urban heat-island control strategies for the Indian industrial and scientific communities and has provided an estimate of the national energy savings potential of cool roofs in India. These outcomes can be used for developing cool-roof building standards and related policies in India. Additional field studies, built upon the successes and lessons learned from this project, may be helpful to further confirm the scale of potential energy savings from the application of cooler roofs in various regions of India. In the future, a more rigorous meteorological simulation using urbanized (meso-urban) meteorological models should be conducted, which may produce a more accurate estimate of the air-temperature reductions for the entire urban area.« less
ERIC Educational Resources Information Center
Wilkinson, Ron
2010-01-01
When construction slows and campus operating expenses are under the microscope, it is more important than ever to save energy dollars with the equipment and staff on hand. For the facilities manager who thinks out of the box, significant savings can be found on most school and college campuses. This article provides energy-conservation tips that…
ESCOs: Helping Schools Save Money and Energy.
ERIC Educational Resources Information Center
School Planning & Management, 2000
2000-01-01
Discusses the use of energy savings performance contracts to help reduce costs and improve school infrastructure and the educational environment. Further discussed are how indoor air quality reduces health, productivity, and costs; and examples are provided of how other schools have achieved better school environments and reduced energy costs. (GR)
The conservation nexus: valuing interdependent water and energy savings in Arizona.
Bartos, Matthew D; Chester, Mikhail V
2014-02-18
Water and energy resources are intrinsically linked, yet they are managed separately--even in the water-scarce American southwest. This study develops a spatially explicit model of water-energy interdependencies in Arizona and assesses the potential for cobeneficial conservation programs. The interdependent benefits of investments in eight conservation strategies are assessed within the context of legislated renewable energy portfolio and energy efficiency standards. The cobenefits of conservation are found to be significant. Water conservation policies have the potential to reduce statewide electricity demand by 0.82-3.1%, satisfying 4.1-16% of the state's mandated energy-efficiency standard. Adoption of energy-efficiency measures and renewable generation portfolios can reduce nonagricultural water demand by 1.9-15%. These conservation cobenefits are typically not included in conservation plans or benefit-cost analyses. Many cobenefits offer negative costs of saved water and energy, indicating that these measures provide water and energy savings at no net cost. Because ranges of costs and savings for water-energy conservation measures are somewhat uncertain, future studies should investigate the cobenefits of individual conservation strategies in detail. Although this study focuses on Arizona, the analysis can be extended elsewhere as renewable portfolio and energy efficiency standards become more common nationally and internationally.
Dampers, reclaimers and pumps - oh my!
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, D.; Wyatt, E.
1997-07-01
Residential energy retrofitters often hear much hype about new products designed to increased the efficiency of domestic water heating. This article examines how much energy these devices really save and how they save it. Topics covered include the following: nonelectronic flue dampers; recovering heat from wastewater; water that`s neither hear not there, the demand pump which improves continuous recirculation of water; cost savings. 1 fig.
2011 Naval Energy Forum. Volume 2
2011-10-14
APPLIED RESEARCH ASSOCIATES • CHASE SUPPLY, INC. • ESPEY MGF. & ELECTRONICS • FREE FLOW POWER • LIVEFUELS • MILSPRAY MILITARY TECHNOLOGIES • PETRA ... Martin Luther King experts reality check? 5 “Heavier-than-air flying machines are impossible” - Lord Kelvin, President, Royal Society, 1895 6 “The...1. Win-Win: Mutual Benefit & Value Proposition – DOD: Save Energy, Save Money, Save Lives (General Martin Dempsey) – DOE: Accelerate technology
Residential Capabilities | Buildings | NREL
components, develop whole-house strategies, and predict performance at various levels of energy savings. This packages at levels of whole-house energy savings. This photo shows a man in front of two computer screens
When energy saving advice leads to more, rather than less, consumption
NASA Astrophysics Data System (ADS)
Revell, Kirsten M. A.; Stanton, Neville A.
2017-01-01
Energy saving technology that relies on behaviour change fails to deliver on its promise. Energy saving advice also has limited effect. This paper examines and reveals how technology and energy saving advice interacts with householders' thought processes to influence energy consumption. A case study of three households that held a 'Feedback' mental model of the home heating thermostat, as defined by Kempton [1986. 'Two Theories of Home Heat Control'. Cognitive Science 10 (1): 75-90], was undertaken to understand the driver behind differences in their home heating strategies, and the effect on energy consumption. Analysis was undertaken from five different data sources comprising: (1) boiler on durations, (2) thermostat set point adjustments, (3) self-reported strategies with home heating controls, (4) user mental model descriptions of the home heating system, and (5) Interview transcripts. The authors found that differences in user mental models of home heating at the system level explained differences in the strategies chosen at the control device level. Differences in boiler on periods were found to relate to limitations of the 'Feedback' mental model; that is, the model fails to consider the effect of the movement of warm air within the home and the impact of internal/external temperature differentials on heat loss rates. The authors argue that technology and advice should be tailored to the thought processes adopted by householders in order to promote behaviour that would realise intended energy savings.
Automatic Energy Schemes for High Performance Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sundriyal, Vaibhav
Although high-performance computing traditionally focuses on the efficient execution of large-scale applications, both energy and power have become critical concerns when approaching exascale. Drastic increases in the power consumption of supercomputers affect significantly their operating costs and failure rates. In modern microprocessor architectures, equipped with dynamic voltage and frequency scaling (DVFS) and CPU clock modulation (throttling), the power consumption may be controlled in software. Additionally, network interconnect, such as Infiniband, may be exploited to maximize energy savings while the application performance loss and frequency switching overheads must be carefully balanced. This work first studies two important collective communication operations, all-to-allmore » and allgather and proposes energy saving strategies on the per-call basis. Next, it targets point-to-point communications to group them into phases and apply frequency scaling to them to save energy by exploiting the architectural and communication stalls. Finally, it proposes an automatic runtime system which combines both collective and point-to-point communications into phases, and applies throttling to them apart from DVFS to maximize energy savings. The experimental results are presented for NAS parallel benchmark problems as well as for the realistic parallel electronic structure calculations performed by the widely used quantum chemistry package GAMESS. Close to the maximum energy savings were obtained with a substantially low performance loss on the given platform.« less
ERIC Educational Resources Information Center
Esteves, Richard M.
1984-01-01
This article analyzes cooperative programs that reduce the risks of financing energy conservation equipment. Savings guarantees, cash flow leasing, shared savings, and cooperative savings programs are described and sources of further information noted. (MJL)
Electric energy savings from new technologies. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrer, B.J.; Kellogg, M.A.; Lyke, A.J.
1986-09-01
Purpose of the report is to provide information about the electricity-saving potential of new technologies to OCEP that it can use in developing alternative long-term projections of US electricity consumption. Low-, base-, and high-case scenarios of the electricity savings for 10 technologies were prepared. The total projected annual savings for the year 2000 for all 10 technologies were 137 billion kilowatt hours (BkWh), 279 BkWh, and 470 BkWh, respectively, for the three cases. The magnitude of these savings projections can be gauged by comparing them to the Department's reference case projection for the 1985 National Energy Policy Plan. In themore » Department's reference case, total consumption in 2000 is projected to be 3319 BkWh. Because approximately 75% of the base-case estimate of savings are already incorporated into the reference projection, only 25% of the savings estimated here should be subtracted from the reference projection for analysis purposes.« less
Energy Savings Forecast of Solid-State Lighting in General Illumination Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Penning, Julie; Stober, Kelsey; Taylor, Victor
2016-09-01
The DOE report, Energy Savings Forecast of Solid-State Lighting in General Illumination Applications, is a biannual report which models the adoption of LEDs in the U.S. general-lighting market, along with associated energy savings, based on the full potential DOE has determined to be technically feasible over time. This version of the report uses an updated 2016 U.S. lighting-market model that is more finely calibrated and granular than previous models, and extends the forecast period to 2035 from the 2030 limit that was used in previous editions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W; Khawaja, M. Sami; Rushton, Josh
Evaluating an energy efficiency program requires assessing the total energy and demand saved through all of the energy efficiency measures provided by the program. For large programs, the direct assessment of savings for each participant would be cost-prohibitive. Even if a program is small enough that a full census could be managed, such an undertaking would almost always be an inefficient use of evaluation resources. The bulk of this chapter describes methods for minimizing and quantifying sampling error. Measurement error and regression error are discussed in various contexts in other chapters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Tiessen, Alex
Retrocommissioning (RCx) is a systematic process for optimizing energy performance in existing buildings. It specifically focuses on improving the control of energy-using equipment (e.g., heating, ventilation, and air conditioning [HVAC] equipment and lighting) and typically does not involve equipment replacement. Field results have shown proper RCx can achieve energy savings ranging from 5 percent to 20 percent, with a typical payback of two years or less (Thorne 2003). The method presented in this protocol provides direction regarding: (1) how to account for each measure's specific characteristics and (2) how to choose the most appropriate savings verification approach.
Feasibility study on an energy-saving desiccant wheel system with CO2 heat pump
NASA Astrophysics Data System (ADS)
Liu, Yefeng; Meng, Deren; Chen, Shen
2018-02-01
In traditional desiccant wheel, air regeneration process occurs inside an open loop, and lots of energy is consumed. In this paper, an energy-saving desiccant wheel system with CO2 heat pump and closed loop air regeneration is proposed. The general theory and features of the desiccant wheel are analysed. The main feature of the proposed system is that the air regeneration process occurs inside a closed loop, and a CO2 heat pump is utilized inside this loop for the air regeneration process as well as supplying cooling for the process air. The simulation results show that the proposed system can save significant energy.
Vapor compression distiller and membrane technology for water revitalization
NASA Technical Reports Server (NTRS)
Ashida, A.; Mitani, K.; Ebara, K.; Kurokawa, H.; Sawada, I.; Kashiwagi, H.; Tsuji, T.; Hayashi, S.; Otsubo, K.; Nitta, K.
1987-01-01
Water revitalization for a space station can consist of membrane filtration processes and a distillation process. Water recycling equipment using membrane filtration processes was manufactured for ground testing. It was assembled using commercially available components. Two systems for the distillation are studied: one is absorption type thermopervaporation cell and the other is a vapor compression distiller. Absorption type thermopervaporation, able to easily produce condensed water under zero gravity, was investigated experimentally and through simulated calculation. The vapor compression distiller was studied experimentally and it offers significant energy savings for evaporation of water.
Vapor compression distiller and membrane technology for water revitalization.
Ashida, A; Mitani, K; Ebara, K; Kurokawa, H; Sawada, I; Kashiwagi, H; Tsuji, T; Hayashi, S; Otsubo, K; Nitta, K
1987-01-01
Water revitalization for a space station can consist of membrane filtration processes and a distillation process. Water recycling equipment using membrane filtration processes was manufactured for ground testing. It was assembled using commercially available components. Two systems for the distillation are studied; one is an absorption type thermopervaporation cell and the other is a vapor compression distiller. Absorption type thermopervaporation able to easily produce condensed water under zero gravity was investigated experimentally and through simulated calculation. The vapor compression distiller was studied experimentally and it offers significant energy savings for evaporation of water.
JPRS Report, Science & Technology, China: Energy.
1988-02-10
bedrock growth anticlines, buried hill fault blocks, rolling anticlines, compression anticlines, draped anticlines, volcanic diapers and others. The...development and utilization of solar , wind, geothermal and other energy resources, the energy conservation capacity and newly-added energy resources were...equivalent to 20 million tons of standard coal. The firewood-saving capacity in wood and coal-saving stoves, biogas pits and solar cookers alone was
Impact of Sustainable Cool Roof Technology on Building Energy Consumption
NASA Astrophysics Data System (ADS)
Vuppuluri, Prem Kiran
Highly reflective roofing systems have been analyzed over several decades to evaluate their ability to meet sustainability goals, including reducing building energy consumption and mitigating the urban heat island. Studies have isolated and evaluated the effects of climate, surface reflectivity, and roof insulation on energy savings, thermal load mitigation and also ameliorating the urban heat island. Other sustainable roofing systems, like green-roofs and solar panels have been similarly evaluated. The motivation for the present study is twofold: the first goal is to present a method for simultaneous evaluation and inter-comparison of multiple roofing systems, and the second goal is to quantitatively evaluate the realized heating and cooling energy savings associated with a white roof system compared to the reduction in roof-top heat flux. To address the first research goal a field experiment was conducted at the International Harvester Building located in Portland, OR. Thermal data was collected for a white roof, vegetated roof, and a solar panel shaded vegetated roof, and the heat flux through these roofing systems was compared against a control patch of conventional dark roof membrane. The second research goal was accomplished using a building energy simulation program to determine the impact of roof area and roof insulation on the savings from a white roof, in both Portland and Phoenix. The ratio of cooling energy savings to roof heat flux reduction from replacing a dark roof with a white roof was 1:4 for the month of July, and 1:5 annually in Portland. The COP of the associated chillers ranges from 2.8-4.2, indicating that the ratio of cooling energy savings to heat flux reduction is not accounted for solely by the COP of the chillers. The results of the building simulation indicate that based on energy savings alone, white roofs are not an optimal choice for Portland. The benefits associated with cooling energy savings relative to a black roof are offset by the winter-time penalty, and the net benefit from adopting white roof technology in Portland is small. That said, there are other potential benefits of white roofing such as impact on urban heat islands and roof life that must also be considered.
Javitt, J C; Aiello, L P; Chiang, Y; Ferris, F L; Canner, J K; Greenfield, S
1994-08-01
Diabetic retinopathy, which leads to macular edema and retinal neovascularization, is the leading cause of blindness among working-age Americans. Previous research has demonstrated significant cost savings associated with detection of eye disease in Americans with type I diabetes. However, detection and treatment of eye disease among those with type II diabetes was previously thought not to be cost-saving. Our purpose was to estimate the current and potential federal savings resulting from the screening and treatment of retinopathy in patients with type II diabetes, based on recently available data concerning efficacy of treating both macular edema and neovascularization along with new data on federal budgetary costs of blindness. We used computer modeling, incorporating data from population-based epidemiological studies and multicenter clinical trials. Monte Carlo simulation was used, combined with sensitivity analysis and present value analysis of cost savings. Screening and treatment for eye disease in patients with type II diabetes generates annual savings of $247.9 million to the federal budget and 53,986 person-years of sight, even at current suboptimal (60%) levels of care. If all patients with type II diabetes receive recommended care, the predicted net savings (discounted at 5%) exceeds $472.1 million and 94,304 person-years of sight. Nearly all savings are associated with detection and treatment of diabetic macular edema. Enrolling each additional person with type II diabetes into currently recommended ophthalmological care results in an average net savings of $975/person, even if all costs of care are borne by the federal government. Our analysis indicates that prevention programs aimed at improving eye care for patients with diabetes not only reduce needless vision loss but also will provide a financial return on the investment of public funds.
Analysis of NREL Cold-Drink Vending Machines for Energy Savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deru, M.; Torcellini, P.; Bottom, K.
NREL Staff, as part of Sustainable NREL, an initiative to improve the overall energy and environmental performance of the lab, decided to control how its vending machines used energy. The cold-drink vending machines across the lab were analyzed for potential energy savings opportunities. This report gives the monitoring and the analysis of two energy conservation measures applied to the cold-drink vending machines at NREL.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Bo; Baxter, Van D.; Rice, C. Keith
For this study, we authored a new air source integrated heat pump (AS-IHP) model in EnergyPlus, and conducted building energy simulations to demonstrate greater than 50% average energy savings, in comparison to a baseline heat pump with electric water heater, over 10 US cities, based on the EnergyPlus quick-service restaurant template building. We also assessed water heating energy saving potentials using ASIHP versus gas heating, and pointed out climate zones where AS-IHPs are promising.
High-Performance Schools: Affordable Green Design for K-12 Schools; Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plympton, P.; Brown, J.; Stevens, K.
2004-08-01
Schools in the United States spend $7.8 billion on energy each year-more than the cost of computers and textbooks combined, according to a 2003 report from the National Center for Education Statistics. The U.S. Department of Energy (DOE) estimates that these high utility bills could be reduced as much as 25% if schools adopt readily available high performance design principles and technologies. Accordingly, hundreds of K-12 schools across the country have made a commitment to improve the learning and teaching environment of schools while saving money and energy and protecting the environment. DOE and its public- and private-sector partners havemore » developed Energy Design Guidelines for High Performance Schools, customized for nine climate zones in U.S. states and territories. These design guidelines provide information for school decision makers and design professionals on the advantages of energy efficiency and renewable energy designs and technologies. With such features as natural day lighting, efficient electric lights, water conservation, and renewable energy, schools in all types of climates are proving that school buildings, and the students and teachers who occupy them, are indeed high performers. This paper describes high performance schools from each of the nine climate zones associated with the Energy Design Guidelines. The nine case studies focus on the high performance design strategies implemented in each school, as well as the cost savings and benefits realized by students, faculty, the community, and the environment.« less
Wang, Li; Xi, Feng Ming; Li, Jin Xin; Liu, Li Li
2016-09-01
Taking 39 industries as independent decision-making units in Liaoning Province from 2003 to 2012 and considering the benefits of energy, economy and environment, we combined direction distance function and radial DEA method to estimate and decompose the energy conservation and carbon emissions reduction efficiency of the industries. Carbon emission of each industry was calculated and defined as an undesirable output into the model of energy saving and carbon emission reduction efficiency. The results showed that energy saving and carbon emission reduction efficiency of industries had obvious heterogeneity in Liaoning Province. The whole energy conservation and carbon emissions reduction efficiency in each industry of Liaoning Province was not high, but it presented a rising trend. Improvements of pure technical efficiency and scale efficiency were the main measures to enhance energy saving and carbon emission reduction efficiency, especially scale efficiency improvement. In order to improve the energy saving and carbon emission reduction efficiency of each industry in Liaoning Province, we put forward that Liaoning Province should adjust industry structure, encourage the development of low carbon high benefit industries, improve scientific and technological level and adjust the industry scale reasonably, meanwhile, optimize energy structure, and develop renewable and clean energy.
No Cost – Low Cost Compressed Air System Optimization in Industry
NASA Astrophysics Data System (ADS)
Dharma, A.; Budiarsa, N.; Watiniasih, N.; Antara, N. G.
2018-04-01
Energy conservation is a systematic, integrated of effort, in order to preserve energy sources and improve energy utilization efficiency. Utilization of energy in efficient manner without reducing the energy usage it must. Energy conservation efforts are applied at all stages of utilization, from utilization of energy resources to final, using efficient technology, and cultivating an energy-efficient lifestyle. The most common way is to promote energy efficiency in the industry on end use and overcome barriers to achieve such efficiency by using system energy optimization programs. The facts show that energy saving efforts in the process usually only focus on replacing tools and not an overall system improvement effort. In this research, a framework of sustainable energy reduction work in companies that have or have not implemented energy management system (EnMS) will be conducted a systematic technical approach in evaluating accurately a compressed-air system and potential optimization through observation, measurement and verification environmental conditions and processes, then processing the physical quantities of systems such as air flow, pressure and electrical power energy at any given time measured using comparative analysis methods in this industry, to provide the potential savings of energy saving is greater than the component approach, with no cost to the lowest cost (no cost - low cost). The process of evaluating energy utilization and energy saving opportunities will provide recommendations for increasing efficiency in the industry and reducing CO2 emissions and improving environmental quality.
Energy Efficiency Strategies for Municipal Wastewater Treatment Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daw, J.; Hallett, K.; DeWolfe, J.
2012-01-01
Water and wastewater systems are significant energy consumers with an estimated 3%-4% of total U.S. electricity consumption used for the movement and treatment of water and wastewater. Water-energy issues are of growing importance in the context of water shortages, higher energy and material costs, and a changing climate. In this economic environment, it is in the best interest for utilities to find efficiencies, both in water and energy use. Performing energy audits at water and wastewater treatment facilities is one way community energy managers can identify opportunities to save money, energy, and water. In this paper the importance of energymore » use in wastewater facilities is illustrated by a case study of a process energy audit performed for Crested Butte, Colorado's wastewater treatment plant. The energy audit identified opportunities for significant energy savings by looking at power intensive unit processes such as influent pumping, aeration, ultraviolet disinfection, and solids handling. This case study presents best practices that can be readily adopted by facility managers in their pursuit of energy and financial savings in water and wastewater treatment. This paper is intended to improve community energy managers understanding of the role that the water and wastewater sector plays in a community's total energy consumption. The energy efficiency strategies described provide information on energy savings opportunities, which can be used as a basis for discussing energy management goals with water and wastewater treatment facility managers.« less
NASA Astrophysics Data System (ADS)
Kordana, Sabina; Słys, Daniel
2017-11-01
The paper analyses the profitability of the use of Drain Water Heat Recovery units. An original simulation model was used for this purpose, and a detached residential building located in Poland was selected as the test facility. The conducted analysis proved that the type of the hot water heater has decisive influence on the profitability level of such an investment. Application of the abovementioned technology is particularly profitable, when water is heated with the use of an electrical device. When the energy source in the system is a gas water heater, the obtained calculation results are not as favourable, and the period of investment return in many cases exceeds the expected service life of these devices. Moreover, the analysis demonstrated that the potential energy savings, and thus also the financial savings, may be in both cases increased as a result of simultaneous intake of water from various water taps.
Zheng, Shaokui; Cui, Cancan; Quan, Ying; Sun, Jian
2013-07-01
This study experimentally examined the microaerobic dissolved oxygen (DO)-induced microbial mechanisms that are responsible for enormous energy savings in the upflow microaerobic sludge blanket reactor (UMSB) for domestic wastewater treatment. Phylogenetic and kinetic analyses (as determined by clone library analyses and sludge oxygen affinity analyses) showed that the microaerobic conditions in the UMSB led to the proliferation and dominance of microaerophilic bacteria that have higher oxygen affinities (i.e., lower sludge oxygen half-saturation constant values), which assured efficient COD and NH3-N removals and sludge granulation in the UMSB similar as those achieved in the aerobic control. However, the microaerobic DO level in the UMSB achieved significant short-cut nitrification, a 50-90% reduction in air supply, and an 18-28% reduction in alkali consumption. Furthermore, the disappearance of sludge bulking in the UMSB when it was dominated by "bulking-induced" filamentous bacteria should be attributed to its upflow column-type configuration. Copyright © 2013 Elsevier Ltd. All rights reserved.
Verify by Genability - Providing Solar Customers with Accurate Reports of Utility Bill Cost Savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
The National Renewable Energy Laboratory (NREL), partnering with Genability and supported by the U.S. Department of Energy's SunShot Incubator program, independently verified the accuracy of Genability's monthly cost savings.
Environmental benefit analysis of strategies for potable water savings in residential buildings.
Marinoski, Ana Kelly; Rupp, Ricardo Forgiarini; Ghisi, Enedir
2018-01-15
The objective of this study is to assess the environmental benefit of using rainwater, greywater, water-efficient appliances and their combinations in low-income houses. The study was conducted surveying twenty households located in southern Brazil, which resulted in water end-uses estimation. Then, embodied energy, potential for potable water savings and sewage reduction when using the different strategies were estimated. The environmental benefit analysis of these strategies was performed using an indicator that includes embodied energy, potable water savings, reduction of sewage and energy consumption in the water utility, and sewage production during the life cycle of the system. The results indicated that the strategy with the greatest environmental benefit is the use of water-efficient appliances, which resulted in substantial water savings and reduction of sewage, causing low environmental impact due to lower embodied energy over the life cycle. Copyright © 2017 Elsevier Ltd. All rights reserved.
Application of Waste Heat Recovery Energy Saving Technology in Reform of UHP-EAF
NASA Astrophysics Data System (ADS)
Zhao, J. H.; Zhang, S. X.; Yang, W.; Yu, T.
2017-08-01
The furnace waste heat of a company’s existing 4 × 100t ultra-high-power electric arc furnaces is not used and discharged directly of the situation has been unable to meet the national energy-saving emission reduction requirements, and also affected their own competitiveness and sustainable development. In order to make full use of the waste heat of the electric arc furnace, this paper presents an the energy-saving transformation program of using the new heat pipe boiler on the existing ultra-high-power electric arc furnaces for recovering the waste heat of flue gas. The results show that after the implementation of the project can save energy equivalent to 42,349 tons of standard coal. The flue gas waste heat is fully utilized and dust emission concentration is accorded with the standard of Chinese invironmental protection, which have achieved good results.
Building Energy Model Development for Retrofit Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chasar, David; McIlvaine, Janet; Blanchard, Jeremy
2012-09-30
Based on previous research conducted by Pacific Northwest National Laboratory and Florida Solar Energy Center providing technical assistance to implement 22 deep energy retrofits across the nation, 6 homes were selected in Florida and Texas for detailed post-retrofit energy modeling to assess realized energy savings (Chandra et al, 2012). However, assessing realized savings can be difficult for some homes where pre-retrofit occupancy and energy performance are unknown. Initially, savings had been estimated using a HERS Index comparison for these homes. However, this does not account for confounding factors such as occupancy and weather. This research addresses a method to moremore » reliably assess energy savings achieved in deep energy retrofits for which pre-retrofit utility bills or occupancy information in not available. A metered home, Riverdale, was selected as a test case for development of a modeling procedure to account occupancy and weather factors, potentially creating more accurate estimates of energy savings. This “true up” procedure was developed using Energy Gauge USA software and post-retrofit homeowner information and utility bills. The 12 step process adjusts the post-retrofit modeling results to correlate with post-retrofit utility bills and known occupancy information. The “trued” post retrofit model is then used to estimate pre-retrofit energy consumption by changing the building efficiency characteristics to reflect the pre-retrofit condition, but keeping all weather and occupancy-related factors the same. This creates a pre-retrofit model that is more comparable to the post-retrofit energy use profile and can improve energy savings estimates. For this test case, a home for which pre- and post- retrofit utility bills were available was selected for comparison and assessment of the accuracy of the “true up” procedure. Based on the current method, this procedure is quite time intensive. However, streamlined processing spreadsheets or incorporation into existing software tools would improve the efficiency of the process. Retrofit activity appears to be gaining market share, and this would be a potentially valuable capability with relevance to marketing, program management, and retrofit success metrics.« less
Energy savings in Polish buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Markel, L.C.; Gula, A.; Reeves, G.
1995-12-31
A demonstration of low-cost insulation and weatherization techniques was a part of phase 1 of the Krakow Clean Fossil Fuels and Energy Efficient Project. The objectives were to identify a cost-effective set of measures to reduce energy used for space heating, determine how much energy could be saved, and foster widespread implementation of those measures. The demonstration project focused on 4 11-story buildings in a Krakow housing cooperative. Energy savings of over 20% were obtained. Most important, the procedures and materials implemented in the demonstration project have been adapted to Polish conditions and applied to other housing cooperatives, schools, andmore » hospitals. Additional projects are being planned, in Krakow and other cities, under the direction of FEWE-Krakow, the Polish Energie Cities Network, and Biuro Rozwoju Krakowa.« less
Assessment of the Impacts of Standards and Labeling Programs inMexico (four products).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanchez, Itha; Pulido, Henry; McNeil, Michael A.
2007-06-12
This study analyzes impacts from energy efficiency standards and labeling in Mexico from 1994 through 2005 for four major products: household refrigerators, room air conditioners, three-phase (squirrel cage) induction motors, and clothes washers. It is a retrospective analysis, seeking to assess verified impacts on product efficiency in the Mexican market in the first ten years after standards were implemented. Such an analysis allows the Mexican government to compare actual to originally forecast program benefits. In addition, it provides an extremely valuable benchmark for other countries considering standards, and to the energy policy community as a whole. The methodology for evaluationmore » begins with historical test data taken for a large number of models of each product type between 1994 and 2005. The pre-standard efficiency of models in 1994 is taken as a baseline throughout the analysis. Model efficiency data were provided by an independent certification laboratory (ANCE), which tested products as part of the certification and enforcement mechanism defined by the standards program. Using this data, together with economic and market data provided by both government and private sector sources, the analysis considers several types of national level program impacts. These include: Energy savings; Environmental (emissions) impacts, and Net financial impacts to consumers, manufacturers and utilities. Energy savings impacts are calculated using the same methodology as the original projections, allowing a comparison. Other impacts are calculated using a robust and sophisticated methodology developed by the Instituto de Investigaciones Electricas (IIE) and Lawrence Berkeley National Laboratory (LBNL), in a collaboration supported by the Collaborative Labeling and Standards Program (CLASP).« less
Recent Advances and Research Status in Energy Conservation of Iron Ore Sintering in China
NASA Astrophysics Data System (ADS)
Wang, Yao-Zu; Zhang, Jian-Liang; Liu, Zheng-Jian; Du, Cheng-Bo
2017-11-01
For the ferrous burden of blast furnaces in China, sinter generally accounts for more than 70% and the sintering process accounts for approximately 6-10% of the total energy consumption of the iron and steel enterprise. Therefore, saving energy during the sintering process is important to reduce the energy consumption in the iron and steel industry. This paper aims to illustrate recent advances and the research status of energy conservation of iron ore sintering in China. It focuses on the development and application of energy-saving technologies such as the composite agglomeration process, sintering with high-proportion flue gas recirculation sintering, recovery of sensible heat from the sinter cooling process, homogeneous deep-bed sintering technology, and comprehensive treatment technology of leakage of sintering. Moreover, some suggestions for the future development of energy-saving technologies are put forward.
Energy use and conservation trends, 1972--1986
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klan, M.S.; Belzer, D.B.; Marsh, S.J.
1989-02-01
US trends in energy use and conservation since 1972 are analyzed in this report. That year represents the last year prior to significant energy price shocks. In 1986, an estimated 31.8 quads has been saved in the US compared with what consumption would have been if the energy use per dollar of GNP had continued on the same trend after 1972 as in the period 1960--1972. Actual US energy consumption in 1986 was 74.3 quads. It is clear that energy conservation is persistent and conservation investments continue to pay off even after initial energy price shocks have subsided. Separate analysesmore » have been conducted for the major end-use sectors (residential, commercial, industrial, and transportation). Savings have been estimated in each sector, and the factors contributing to sectoral savings identified. 19 refs., 23 figs., 26 tabs.« less
ResStock Analysis Tool | Buildings | NREL
Energy and Cost Savings for U.S. Homes Contact Eric Wilson to learn how ResStock can benefit your approach to large-scale residential energy analysis by combining: Large public and private data sources uncovered $49 billion in potential annual utility bill savings through cost-effective energy efficiency
Tool to Prioritize Energy Efficiency Investments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farese, P.; Gelman, R.; Hendron, R.
2012-08-01
To provide analytic support of the U.S. Department of Energy's Office of the Building Technology Program (BTP), NREL developed a Microsoft Excel-based tool to provide an open and objective comparison of the hundreds of investment opportunities available to BTP. This tool uses established methodologies to evaluate the energy savings and cost of those savings.
NASA Astrophysics Data System (ADS)
Onogaki, Hitoshi; Yokoyama, Shuichi
The temperature control of the environmental examination device has loss of the energy consumption to cool it while warming it. This paper proposed a tempareture control system method with energy saving for the enviromental examination device without using cooling in consideration of temperature characteristics.
The Energy Smart Guide to Campus Cost Savings.
ERIC Educational Resources Information Center
Department of Energy, Washington, DC. Office of Energy Efficiency and Renewable Energy.
Rebuild America is a program of the U.S. Department of Energy that focuses on energy-savings solutions as community solutions. It works with K-12 schools, colleges and universities, state and local governments, public and multifamily housing, and commercial buildings. This guide focuses on colleges and universities. Each chapter spells out options…
Thermal Energy Briefing with FPL
2017-02-17
Ismael H. Otero, NASA Kennedy Space Center's project manager on the thermal energy program, addresses the news media and NASA Social about the new Thermal Energy Storage (TES) tank Feb. 17. The TES tank works like a giant battery and is saving the center utility cost. These savings will be applied to new sustainable projects at Kennedy.
Development of the Advanced Energy Design Guide for K-12 Schools -- 50% Energy Savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonnema, E.; Leach, M.; Pless, S.
2013-02-01
This Technical Support Document (TSD) describes the process and methodology for the development of the Advanced Energy Design Guide for K-12 School Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-K12) (ASHRAE et al. 2011a). The AEDG-K12 provides recommendations for achieving 50% whole-building energy savings in K-12 schools over levels achieved by following ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-K12 was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of Northmore » America (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy (DOE).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonnema, E.; Leach, M.; Pless, S.
2013-06-01
This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-MBBR) ASHRAE et al. (2011b). The AEDG-MBBR is intended to provide recommendations for achieving 50% whole-building energy savings in retail stores over levels achieved by following ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-MBBR was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), themore » Illuminating Engineering Society of North America (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonnema, Eric; Leach, Matt; Pless, Shanti
2013-06-05
This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-MBBR) ASHRAE et al. (2011b). The AEDG-MBBR is intended to provide recommendations for achieving 50% whole-building energy savings in retail stores over levels achieved by following ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-MBBR was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), themore » Illuminating Engineering Society of North America (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy.« less
Evaluation of the "Lose Your Excuse" public service advertising campaign for tweens to save energy.
Bertrand, Jane T; Goldman, Patty; Zhivan, Natalia; Agyeman, Yaw; Barber, Erin
2011-10-01
This study evaluates the 2008-2009 "Lose your Excuse" public service advertising (PSA) campaign on energy efficiency targeting 8- to 12-year-olds, intended to increase knowledge, foster proactive attitudes, and change energy usage behaviors. Baseline and two follow-up surveys were conducted with online samples representative of the national population of households with kids with online access. Almost half (47%) of the tweens recognized at least one ad from the campaign. Ad recognition was positively associated with knowledge, proactive attitudes, and energy-saving behavior. Propensity score analysis confirmed a small but measurable and statistically significant effect on energy-saving behavior. The discussion section compares these results to public health campaigns in terms of ghost awareness, reach, and effect size.
Khan, Yasin; Khare, Vaibhav Rai; Mathur, Jyotirmay; ...
2015-03-26
The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building usingmore » a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. Lastly, the energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.« less
Wastewater treatment process impact on energy savings and greenhouse gas emissions.
Mamais, D; Noutsopoulos, C; Dimopoulou, A; Stasinakis, A; Lekkas, T D
2015-01-01
The objective of this research was to assess the energy consumption of wastewater treatment plants (WWTPs), to apply a mathematical model to evaluate their carbon footprint, and to propose energy saving strategies that can be implemented to reduce both energy consumption and greenhouse gas (GHG) emissions in Greece. The survey was focused on 10 WWTPs in Greece with a treatment capacity ranging from 10,000 to 4,000,000 population equivalents (PE). Based on the results, annual specific energy consumption ranged from 15 to 86 kWh/PE. The highest energy consumer in all the WWTPs was aeration, accounting for 40-75% of total energy requirements. The annual GHG emissions varied significantly according to the treatment schemes employed and ranged between 61 and 161 kgCO₂e/PE. The highest values of CO₂emissions were obtained in extended aeration systems and the lowest in conventional activated sludge systems. Key strategies that the wastewater industry could adopt to mitigate GHG emissions are identified and discussed. A case study is presented to demonstrate potential strategies for energy savings and GHG emission reduction. Given the results, it is postulated that the reduction of dissolved oxygen (DO) set points and sludge retention time can provide significant energy savings and decrease GHG emissions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, Yasin; Singh, Gaurav; Mathur, Jyotirmay
The Radiant cooling system integrated with Dedicated Outdoor Air System (DOAS) is a viable substitution for conventional all air system in order to reduce primary energy consumption, as it decouples the cooling and ventilation task. In DOAS major portion of energy is consumed in cooling coil where it dehumidifies the process supply air. This study describes an alternate solution for dehumidification, with the substitution of the desiccant wheel with solar regeneration in place of a chilled water coil based dehumidifier. In this paper, simulations were carried out using EnergyPlus on a reference medium office building to investigate the contribution ofmore » solar energy towards the total energy consumption of desiccant assisted DOAS with radiant cooling system. To evaluate the system performance and energy saving potential, desiccant based DOAS is compared with cooling coil assisted DOAS integrated with Radiant cooling system. Simulations were carried out for different solar collector area to evaluate primary energy savings. Results indicate that from 7.4 % to 28.6 % energy saving (according to different collector area) can be achieved due to the solar regeneration in desiccant assisted DOAS, the impact of different solar collector area on potential of energy savings is also described.« less
Khan, Yasin; Singh, Gaurav; Mathur, Jyotirmay; ...
2017-06-13
The Radiant cooling system integrated with Dedicated Outdoor Air System (DOAS) is a viable substitution for conventional all air system in order to reduce primary energy consumption, as it decouples the cooling and ventilation task. In DOAS major portion of energy is consumed in cooling coil where it dehumidifies the process supply air. This study describes an alternate solution for dehumidification, with the substitution of the desiccant wheel with solar regeneration in place of a chilled water coil based dehumidifier. In this paper, simulations were carried out using EnergyPlus on a reference medium office building to investigate the contribution ofmore » solar energy towards the total energy consumption of desiccant assisted DOAS with radiant cooling system. To evaluate the system performance and energy saving potential, desiccant based DOAS is compared with cooling coil assisted DOAS integrated with Radiant cooling system. Simulations were carried out for different solar collector area to evaluate primary energy savings. Results indicate that from 7.4 % to 28.6 % energy saving (according to different collector area) can be achieved due to the solar regeneration in desiccant assisted DOAS, the impact of different solar collector area on potential of energy savings is also described.« less
Solar water-heating performance evaluation-San Diego, California
NASA Technical Reports Server (NTRS)
1981-01-01
Report describes energy saved by replacing domestic, conventional natural gas heater with solar-energy subsystem in single-family residence near San Diego, California. Energy savings for 6 month test period averaged 1.089 million Btu. Collector array covered 65 square feet and supplied hot water to both 66-gallon solar storage tank and 40-gallon tank for domestic use. Natural gas supplied house's auxiliary energy.
Solar energy system performance evaluation. Seasonal report for Wormser, Columbia, South Carolina
NASA Technical Reports Server (NTRS)
1980-01-01
The Wormser Solar Energy System's operational performance from April 1979 through March 1980 was evaluated. The space heating subsystem met 42 percent of the measured space heating load and the hot water subsystem met 23 percent of the measured hot water demand. Net electrical energy savings were 4.36 million Btu's or 1277 kwh. Fossil energy savings will increase considerably if the uncontrolled solar energy input to the building is considered.
Energy management system saves $250,000 + fuel -with 4-mo payback
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massey, C.L.; Robe, K.
1980-09-01
Innovations made at Hershey Chocolate Company's Oakdale, California plant eliminated simultaneous cool-reheat-cycles by incorporating dead band controls into existing HVAC systems. Calculated savings of the project are about 90% of former heating and cooling energy usage for HVAC operation. Electric power savings amount to about $75,000/y, and natural gas savings about $185,000/y, using 1980 fuel costs, with an approximate 4-month payback. Because of the reduced demand for chilled water, a smaller water chiller carries full plant load for 4 to 5 months of the year without operating two existing 500-ton units.
SMART Scale An Innovative Program Accelerating the Energy Efficiency Market
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, Colin; Aldridge, Mahlon; Higgins, Cathy
Small business is a major component of the American economy. More than half of all private sector workers in this country are employed by small businesses and nearly two-thirds of the new jobs generated in the last ten years were created in this sector. Studies have shown that buildings of less than 50,000 square feet represent 94% of the commercial sector and half of all non-residential floor space in the United States. The future of the American economy relies on a vibrant, robust, and profitable small business community. Small and mid-sized businesses (SMB) can increase their profitability by reducing theirmore » operating costs through energy efficiency. The SMART Scale program delivers deep retrofits that maximize energy and cost savings for the SMB market and can be adapted throughout the country in markets of all sizes. For the past 14 years, Ecology Action has been perfecting a Direct Install (DI) program for the SMB market that offers this sector the type of sophisticated, comprehensive energy saving opportunities that were previously available only to large commercial and industrial customers. The DI 2.0 model that Ecology Action has administered for several public and investor-owned California utilities, and most recently for the Sacramento Municipal Utilities District (SMUD), provides the template for a successful retrofit program that can address the unique barriers faced by the SMB sector and achieve a greater impact than traditional DI programs. The impressive results produced by the DI 2.0 program prompted the US Department of Energy to award Ecology Action a $2 million grant in 2013 to create, demonstrate and roll out a replicable model for delivering deep retrofits to small commercial buildings. The grant enabled Ecology Action to build on the success of DI 2.0 by incorporating improvements into the model, market-testing it and designing a costeffective method of achieving significant energy savings for small businesses across the country.« less
NASA Astrophysics Data System (ADS)
Howard, R. G.
The active solar energy system for a recreation hall for senior citizens in Wisconsin, is equipped with 1290 square feet of evacuated tube collectors, 3000 gallons of water in a tank, and a natural gas fired furnace for auxiliary space heating and a natural gas fired domestic water heater. The solar fraction, solar savings ratio, conventional fuel savings, system performance factor, and solar system coefficient of performance are given as well as performance data for the collector, storage, domestic hot water, and space heating subsystems, operating energy, energy savings, and weather conditions. Predicted performance data are also given for comparison with the measured data.
Energy savings potential in air conditioners and chiller systems
Kaya, Durmus; Alidrisi, Hisham
2014-01-22
In the current paper we quantified and evaluated the energy saving potential in air conditioners and chiller systems. Here, we also showed how to reduce the cost of air conditioners and chiller systems in existing facilities on the basis of payback periods. Among the measures investigated were: (1) installing higher efficiency air conditioners, (2) installing higher efficiency chillers, (3) duty cycling air conditioning units, and (4) utilizing existing economizers on air conditioning units. For each method, examples were provided from Arizona, USA. In these examples, the amount of saved energy, the financial evaluation of this energy, and the investment costmore » and pay back periods were calculated.« less
NASA Technical Reports Server (NTRS)
1975-01-01
The role played by individual citizens as consumers of energy was examined, with emphasis on studying ways in which their action could result in energy conservation. It was shown that there are ways that energy can be conserved in this way, with citizens acting either individually or in groups. The potential savings are significant, but the actual savings may be quite small. The citizens need to be motivated to save and to believe in a conservation ethic; developing such an ethic is difficult, and perhaps not responsive to the shotgun approach now being attempted. The true course of action may be to synthesize new societal structures that provide the maximum evolution of culture within the limitation of scarce energy resources.
Consumers’ perceptions of energy use and energy savings: A literature review
NASA Astrophysics Data System (ADS)
Lesic, Vedran; Bruine de Bruin, Wändi; Davis, Matthew C.; Krishnamurti, Tamar; Azevedo, Inês M. L.
2018-03-01
Background. Policy makers and program managers need to better understand consumers’ perceptions of their energy use and savings to design effective strategies for promoting energy savings. Methods. We reviewed 14 studies from the emerging interdisciplinary literature examining consumers’ perceptions electricity use by specific appliances, and potential savings. Results. We find that: (1) electricity use is often overestimated for low-energy consuming appliances, and underestimated for high-energy consuming appliances; (2) curtailment strategies are typically preferred over energy efficiency strategies; (3) consumers lack information about how much electricity can be saved through specific strategies; (4) consumers use heuristics for assessing the electricity use of specific appliances, with some indication that more accurate judgments are made among consumers with higher numeracy and stronger pro-environmental attitudes. However, design differences between studies, such as variations in reference points, reporting units and assessed time periods, may affect consumers’ reported perceptions. Moreover, studies differ with regard to whether accuracy of perceptions was evaluated through comparisons with general estimates of actual use, self-reported use, household-level meter readings, or real-time smart meter readings. Conclusion. Although emerging findings are promising, systematic variations in the measurement of perceived and actual electricity use are potential cause for concern. We propose avenues for future research, so as to better understand, and possibly inform, consumers’ perceptions of their electricity use. Ultimately, this literature will have implications for the design of effective electricity feedback for consumers, and related policies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Stoughton, Kate M; Figueroa, Jorge
This measurement and verification (M&V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with outdoor irrigation efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M&V plan, and details the procedures to use to determine water savings.
NASA Astrophysics Data System (ADS)
Gilmanshin, I. R.; Gilmanshina, S. I.
2017-09-01
The urgency of the formation of competence in the field of energy saving in the process of studying engineering and technical disciplines at the university is substantiated. The author’s definition of the competence in the field of energy saving is given, allowing to consider the necessity of its formation among students - future engineers as a way to create technologies of a new generation. The essence of this competence is revealed. The system of work, pedagogical conditions and technologies of its formation in the conditions of the federal university is substantiated.
Peng, Yong-zhen; Guo, Jian-hua; Wang, Shu-ying; Chen, Ying
2008-12-01
How to prevent and control filamentous bulking sludge has being a research focus and attracted much attention. To date despite the extensive research that has been done on bulking sludge, filamentous bulking still occurs world-wide and a comprehensive solution does not seem to be available. Particularly, there are few studies about making use of the characteristics of filamentous bacteria and achieving energy saving by filamentous bulking. Limited filamentous bulking, a novel method for energy saving while equal or better treatment performance by allowing slight and controlled filamentous bulking sludge at low dissolved oxygen (DO), was proposed based on full-scale field observations. The practical operation showed that limited filamentous bulking resulted from a decline in DO concentration. COD, SS and TP removal could be enhanced and energy saving could be achieved by limited filamentous bulking at low DO. The derivation of limited filamentous bulking is introduced firstly, and then the theoretical fundamentals of the technique of limited filamentous bulking are presented and analyzed, including the occurrence of limited filamentous bulking caused by low DO, the enhanced effect of filamentous bacteria on pollutants removal and the energy saving mechanism by using limited filamentous bulking. Besides, the paper provides some new perspectives about the application and research direction of limited filamentous bulking in future.
Aerosol corrosion prevention and energy-saving strategies in the design of green data centers.
Ferrero, Luca; Sangiorgi, Giorgia; Ferrini, Barbara S; Perrone, Maria G; Moscatelli, Marco; D'Angelo, Luca; Rovelli, Grazia; Ariatta, Alberto; Truccolo, Redy; Bolzacchini, Ezio
2013-04-16
The energy demands of data centers (DCs) worldwide are rapidly increasing, as are their environmental and economic costs. This paper presents a study conducted at Sannazzaro de' Burgondi (Po Valley), Italy, specifically aimed at optimizing the operating conditions of a DC designed for the Italian Oil and Gas Company (Eni) (5200 m(2) of Information Technology installed, 30 MW) and based on a direct free cooling (DFC) system. The aim of the study was to save the largest possible quantity of energy, while at the same time preventing aerosol corrosion. The aerosol properties (number size distribution, chemical composition, deliquescence relative humidity (DRH), acidity) and meteorological parameters were monitored and utilized to determine the potential levels of aerosol entering the DC (equivalent ISO class), together with its DRH. These data enabled us both to select the DC's filtering system (MERV13 filters) and to optimize the cooling cycle through calculation of the most reliable humidity cycle (60% of maximum allowed RH) applicable to the DFC. A potential energy saving of 81%, compared to a traditional air conditioning cooling system, was estimated: in one year, for 1 kW of installed information technology, the estimated energy saving is 7.4 MWh, resulting in 2.7 fewer tons of CO2 being emitted, and a financial saving of € 1100.
Office-like Test Chambers to Measure Cool Roof Energy Savings in Four Indian Climates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arumugam, Rathish; B, Sasank; T, Rajappa
Selecting a high albedo (solar reflectance) waterproofing layer on the top of a roof helps lower the roof’s surface temperature and reduce the air conditioning energy consumption in the top floor of a building. The annual energy savings depend on factors including weather, internal loads, and building operation schedule. To demonstrate the energy saving potential of high albedo roofs, an apparatus consisting of two nearly identical test chambers (A and B) has been built in four Indian climates: Chennai (hot & humid), Bangalore (temperate), Jhagadia (Hot & dry) and Delhi (composite). Each chamber has well-insulated walls to mimic the coremore » of an office building. Both chambers have the same construction, equipment, and operating schedule, differing only in roof surface. The reinforced cement concrete roof of Chamber A is surfaced with a low-albedo cement layer, while that of Chamber B is surfaced with a high-albedo water proof membrane (change in solar reflectance of 0.28). The experiment will be carried out for one year to explore seasonal variations in energy savings. Initial results in the month of July (post summer) shows that savings from high albedo roof ranges from 0.04 kWh/m2/day in temperate climates, to 0.08 kWh/m2/day in hot & dry climate.« less
Qualified Tuition Savings Programs: The Impact on Household Saving.
ERIC Educational Resources Information Center
Coronado, Julia Lynn; McIntosh, Susan Hume
This study analyzed the impact tuition savings plans are likely to have on household savings. State-sponsored college savings programs rely mainly on tax incentives to motivate parents to save for their children's education in earmarked accounts. The first such programs were prepaid tuition plans, and other types of qualified tuition savings…
The Power of Flexibility: Autonomous Agents That Conserve Energy in Commercial Buildings
NASA Astrophysics Data System (ADS)
Kwak, Jun-young
Agent-based systems for energy conservation are now a growing area of research in multiagent systems, with applications ranging from energy management and control on the smart grid, to energy conservation in residential buildings, to energy generation and dynamic negotiations in distributed rural communities. Contributing to this area, my thesis presents new agent-based models and algorithms aiming to conserve energy in commercial buildings. More specifically, my thesis provides three sets of algorithmic contributions. First, I provide online predictive scheduling algorithms to handle massive numbers of meeting/event scheduling requests considering flexibility , which is a novel concept for capturing generic user constraints while optimizing the desired objective. Second, I present a novel BM-MDP ( Bounded-parameter Multi-objective Markov Decision Problem) model and robust algorithms for multi-objective optimization under uncertainty both at the planning and execution time. The BM-MDP model and its robust algorithms are useful in (re)scheduling events to achieve energy efficiency in the presence of uncertainty over user's preferences. Third, when multiple users contribute to energy savings, fair division of credit for such savings to incentivize users for their energy saving activities arises as an important question. I appeal to cooperative game theory and specifically to the concept of Shapley value for this fair division. Unfortunately, scaling up this Shapley value computation is a major hindrance in practice. Therefore, I present novel approximation algorithms to efficiently compute the Shapley value based on sampling and partitions and to speed up the characteristic function computation. These new models have not only advanced the state of the art in multiagent algorithms, but have actually been successfully integrated within agents dedicated to energy efficiency: SAVES, TESLA and THINC. SAVES focuses on the day-to-day energy consumption of individuals and groups in commercial buildings by reactively suggesting energy conserving alternatives. TESLA takes a long-range planning perspective and optimizes overall energy consumption of a large number of group events or meetings together. THINC provides an end-to-end integration within a single agent of energy efficient scheduling, rescheduling and credit allocation. While SAVES, TESLA and THINC thus differ in their scope and applicability, they demonstrate the utility of agent-based systems in actually reducing energy consumption in commercial buildings. I evaluate my algorithms and agents using extensive analysis on data from over 110,000 real meetings/events at multiple educational buildings including the main libraries at the University of Southern California. I also provide results on simulations and real-world experiments, clearly demonstrating the power of agent technology to assist human users in saving energy in commercial buildings.
2006-12-01
T T Thrust V V Speed (Velocity) in general VA VA Speed of Advance of propeller wQ WQ Taylor Wake Fraction (torque identity) wl- WT Taylor Wake...Wasp, LHD 1 6 $45 M Tarawa, LHA 1 5 $18 M Whidbey Island / Harpers Ferry, 12 $ 24 M LSD 41 /LSD 49 (C) Fleet Auxiliary Force Henry J Kaiser, TAO 187 16...savings are associated with the TAO 187 class. Table 2 shows some general characteristics of these selected U.S. Navy ship classes. The type of prime
Dry-running gas seals save $200,000/yr in retrofit hydrogen recycle compressor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pennacchi, R.P.; Germain, A.
1987-10-01
Texaco Chemical Company was using three drums of oil per day in the seal oil system of a hydrogen recycle compressor, resulting in maintenance and operational expenses of more than $160,000 per year. Running 24 hours/day, 365 days/yr, the 26-yr-old compressor is the heart of the benzene manufacturing process unit at the Port Arthur, Texas plant. In the event of an unscheduled shutdown, the important aromatics unit process would halt and cause production losses of thousands of dollars per day. In addition, the close monitoring and minimization of leakage are essential since the gas consists of over 75% hydrogen, withmore » methane, ethane, propane, isobutane, N-butane and pentanes. Texaco Chemical Company decided that retrofit of the hydrogen recycle compressor should be undertaken if the system could be developed to sharply reduce operations and maintenance costs, and increase efficiencies. Texaco engineers selected a dry running-type gas sealing system developed for pipeline compressors in the United States, Canada, and overseas. A tandem-type sealing system was designed to meet specific needs of a hydrogen recycle compressor. The retrofit was scheduled for August 1986 to coincide with the plant's preventative maintenance program. The seal system installation required five days. The retrofit progressed according to schedule, with no problems experienced at the first and several startups since the initial installation. Oil consumption has been eliminated, along with seal support and parasitic energy requirements. With the savings in seal oil, energy, operations and maintenance, payback period for the retrofit sealing system was just over six months. Savings are expected to continue at an annual rate of over $200,000.« less
Energy Efficiency: An Experiential-Based Energy Unit for Youth Ages 13-18
ERIC Educational Resources Information Center
Poorman, Myken D.; Webster, Nicole
2010-01-01
Not all 16 year olds can buy hybrid cars to help save gas emissions, but they can learn new, easy ways to save energy. Youth are more likely to develop a greater sense of positive impact on the environment if they learn easy and creative ways to use energy more efficiently at a young age. Through the use of practical applications, youth can begin…
Enhanced Thermal Performance of Mosques in Qatar
NASA Astrophysics Data System (ADS)
Touma, A. Al; Ouahrani, D.
2017-12-01
Qatar has an abundance of mosques that significantly contribute to the increasing energy consumption in the country. Little attention has been given to providing mitigation methods that limit the energy demands of mosques without violating the worshippers’ thermal comfort. Most of these researches dealt with enhancing the mosque envelope through the addition of insulation layers. Since most mosque walls in Qatar are mostly already insulated, this study proposes the installation of shading on the mosque roof that is anticipated to yield similar energy savings in comparison with insulated roofs. An actual mosque in Qatar, which is a combination of six different spaces consisting of men and women’s prayer rooms, ablutions and toilets, was simulated and yielded a total annual energy demand of 619.55 kWh/m2. The mosque, whose walls are already insulated, yielded 9.1% energy savings when an insulation layer was added to its roof whereas it produced 6.2% energy savings when a shading layer was added above this roof. As the reconstruction of the roof envelope is practically unrealistic in existing mosques, the addition of shading to the roof was found to produce comparable energy savings. Lastly, it was found that new mosques with thin-roof insulation and shading tend to be more energy-efficient than those with thick-roof insulation.
ERIC Educational Resources Information Center
Comptroller General of the U.S., Washington, DC.
Presented is a study and assessment of the United States Department of Energy State Energy Conservation Program (SECP). The goal of the SECP is to reduce energy consumption in each state by 5% by 1980. However, it is unlikely that this goal will be attained or that the savings reported for 1978 are a valid measure of the program's impact on energy…
NASA Astrophysics Data System (ADS)
Liu, Yefeng; Meng, Deren; Chen, Shen
2018-02-01
In food processing, there are significant simultaneous demands of cooling, warm water and hot water. Most of the heated water is used only once rather than recycled. Current heating and cooling systems consume much energy and emit lots of greenhouse gases. In order to reduce energy consumption and greenhouse gases emission, a transcritical CO2 heat pump system is proposed that can supply not only cooling, but also warm water and hot water simultaneously to meet the thermal demands of food processing. Because the inlet water temperature from environment varies through a year, the energy-saving performance for different seasons is simulated. The results showed that the potential primary energy saving rate of the proposed CO2 heat pump is 50% to 60% during a year.
Data and Analytics to Inform Energy Retrofit of High Performance Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Tianzhen; Yang, Le; Hill, David
Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energymore » audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.« less