Sample records for engerix-b package insert

  1. A randomized, controlled clinical trial to evaluate the immunogenicity of a PreS/S hepatitis B vaccine Sci-B-Vac™, as compared to Engerix B®, among vaccine naïve and vaccine non-responder dialysis patients.

    PubMed

    Elhanan, E; Boaz, M; Schwartz, I; Schwartz, D; Chernin, G; Soetendorp, H; Gal Oz, A; Agbaria, A; Weinstein, T

    2018-02-01

    Dialysis patients have a suboptimal response to hepatitis B (HBV) vaccination. This study aimed to compare the immunogenicity of two vaccines: the third-generation Sci-B-Vac™ vs. the second-generation Engerix B ® . The cohort included two groups of dialysis patients: naïve and previously vaccinated non-responders. Primary endpoints were antibody titers ≥10 IU/L at 3 and 7 month post-vaccination. Secondary objectives were seroprotection rates in vaccine-naïve patients and in previously vaccinated non-responders. Eighty-six patients were assigned to vaccine (Sci-B-Vac™ or Engerix B ® ) using computer-generated randomization, stratified by age, gender, diabetes, and previous HBV vaccination. Sci-B-Vac™ was administered in three doses, 10 μg, at 0, 1, and 6 months in naïve patients; or 20 μg in previously vaccinated non-responders. Engerix B ® included four doses, 40 μg at 0, 1, 2, and 6 months. Each group had 43 patients. Seroconversion was 69.8% with Engerix B ® vs. 73.2% with Sci-B-Vac™. Antibody titers at 7 months were higher with Sci-B-Vac™ (266.4 ± 383.9, median 53.4) than with Engerix ® (193.2 ± 328.9, median 19). However, these differences were not significant, perhaps due to a suboptimal sample size. This study suggests comparable immunogenicity for both vaccines. Thus, we cannot reject the null hypothesis that there is no difference in seroconversion by vaccine type. It is noteworthy that naïve patients were vaccinated with a standard dose of Sci-B-Vac™, while Engerix B ® was administered at a double dose. Similarly, although mean antibody titer levels in the Sci-B-Vac™ group were higher than in the Engerix ® group, this difference did not reach significance. Consequently, a future clinical trial should recruit a larger cohort of patients, using a standard double-dose protocol in both groups.

  2. Randomized comparison of 5 and 10 microgram doses of two recombinant hepatitis B vaccines.

    PubMed

    Bryan, J P; Craig, P G; Reyes, L; Hakre, S; Jaramillo, R; Harlan, H; MacArthy, P; Legters, L J

    1995-08-01

    The high cost of hepatitis B vaccines remains an obstacle to their use. Since the recommended adult dose of Recombivax HB (MSD) is 10 micrograms and that of Engerix B (SKB) is 20 micrograms, we sought to determine if 10 microgram doses of each vaccine are equally immunogenic. Further, since 5 microgram doses of Recombivax are routinely used in those < or = 29 years of age in the US military, we sought to compare this dose with 5 microgram doses of Engerix B. Lower doses of Engerix would result in vaccine cost savings. members of the Belize Defence Force who were > or = 18 years of age (median 24) without detectable anti-HBc were randomly assigned to receive Recombivax, 5 or 10 micrograms, or ENgerix, 5 or 10 micrograms IM at 0, 1, and 6 months. Randomization was weighted toward Engerix. after 3 doses, geometric mean concentrations (GMC) of anti-HBs were highest among those receiving Recombivax 10 micrograms (n=22) or 5 micrograms (n=46) with GMC anti-HBs of 744 and 570 mIU ml-1, respectively. Similar proportions in the two groups developed > or = 10 mIU m-1 anti-HBs (100 and 98%). Among the 91 people who received Engerix 10 micrograms, the GMC anti-HBs was 325 mIU ml-1 and 91% developed > or = 10 mIU ml-1. The 87 people who received Engerix 5 micrograms had the lowest GMC, 177 mIU ml-1 (p < 0.05 compared with either Recombivax group). Only 86% attained > or = 10 mIU ml-1 anti-HBs (p > 0.05 compared with other regimens). The proportion attaining > or = 100 mIU ml-1 was lower in the 5 microgram Engerix group (63%) compared with 80% in the 5 microgram or 95% in the 10 microgram Recombivax groups (p < 0.05). Engerix administered in 5 microgram doses is less immunogenic than 5 or 10 microgram doses of Recombivax. In healthy populations < 30 years of age, regimens of half the recommended adult dose (5 micrograms of Recombivax or 10 micrograms of Engerix) are highly immunogenic and may result in significant vaccine cost savings.

  3. Statistical and Ontological Analysis of Adverse Events Associated with Monovalent and Combination Vaccines against Hepatitis A and B Diseases

    PubMed Central

    Xie, Jiangan; Zhao, Lili; Zhou, Shangbo; He, Yongqun

    2016-01-01

    Vaccinations often induce various adverse events (AEs), and sometimes serious AEs (SAEs). While many vaccines are used in combination, the effects of vaccine-vaccine interactions (VVIs) on vaccine AEs are rarely studied. In this study, AE profiles induced by hepatitis A vaccine (Havrix), hepatitis B vaccine (Engerix-B), and hepatitis A and B combination vaccine (Twinrix) were studied using the VAERS data. From May 2001 to January 2015, VAERS recorded 941, 3,885, and 1,624 AE case reports where patients aged at least 18 years old were vaccinated with only Havrix, Engerix-B, and Twinrix, respectively. Using these data, our statistical analysis identified 46, 69, and 82 AEs significantly associated with Havrix, Engerix-B, and Twinrix, respectively. Based on the Ontology of Adverse Events (OAE) hierarchical classification, these AEs were enriched in the AEs related to behavioral and neurological conditions, immune system, and investigation results. Twenty-nine AEs were classified as SAEs and mainly related to immune conditions. Using a logistic regression model accompanied with MCMC sampling, 13 AEs (e.g., hepatosplenomegaly) were identified to result from VVI synergistic effects. Classifications of these 13 AEs using OAE and MedDRA hierarchies confirmed the advantages of the OAE-based method over MedDRA in AE term hierarchical analysis. PMID:27694888

  4. Antibody persistence and the effect of a booster dose given 5, 10 or 15 years after vaccinating preadolescents with a recombinant hepatitis B vaccine.

    PubMed

    Gilca, Vladimir; De Serres, Gaston; Boulianne, Nicole; Murphy, Donald; De Wals, Philippe; Ouakki, Manale; Trudeau, Gisele; Massé, Richard; Dionne, Marc

    2013-01-07

    The persistence of antibody obtained post-vaccination of preadolescents with three doses of Engerix-B and the effect of a booster administered 5, 10 or 15 years later were monitored in 663 vaccinees. Five, 10 and 15 years post-vaccination >94% of subjects had detectable antibodies and 88.2%, 86.4% and 76.7% had a titre ≥10 IU/L; GMTs were 269 IU/L, 169 IU/L and 51 IU/L, respectively; 99.1-100% vaccinees reached a titre ≥10 IU/l post-booster. GMTs were 118012 IU/L, 32477 IU/L, and 13946 IU/L when the booster was administered 5, 10 or 15 years post-vaccination, respectively. We conclude that vaccination induces immunity in the great majority of vaccinees for at least 15 years. The response to a booster dose suggests persistence of immune memory in almost all vaccinees. Although a booster dose increases substantially anti-HBs titres, the clinical relevance of such an increase remains unknown. These results do not support the need of a booster for at least 15 years when vaccinating preadolescents with Engerix-B. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Hepatitis B vaccine booster dose: low-dose recombinant hepatitis B vaccines as a booster dose.

    PubMed

    Bryan, J P; MacArthy, P; Rudock, A; Fogarty, J P; Dowd, H; Legters, L J; Perine, P L

    1997-06-01

    The timing and best regimen for a booster dose of hepatitis B vaccine have not been determined. Two studies were conducted to determine the response to a booster dose of 5 micrograms recombinant hepatitis B vaccine. In the first study, a 5 micrograms (0.5 ml) dose of Recombivax HB was administered intramuscularly 38 months after the initial dose to 71 volunteers. In a second study, we offered a 5 micrograms dose recombinant hepatitis B vaccine, either Recombivax HB (0.5 ml) or Engerix B (0.25 ml), to students who had previously been immunized with three doses of vaccine. In the first study, among the 44 persons for whom postbooster sera were available, the geometric mean concentration of anti-hepatitis B surface antigens increased from 42 to 2090 mIU/ml after the 5 micrograms (0.5 ml) dose of Recombivax. In the second study, after a 5 micrograms (0.5 ml) dose of Recombivax, the geometric mean concentration increased from 43 to 990 mIU/ml (n = 48), and in the group that received a 5 micrograms (0.25 ml) dose of Engerix B, the concentration increased from 83 to 2337 mIU/ml (n = 45) (p = 0.18 for postdose concentrations). A 5 micrograms dose of recombinant vaccine results in an excellent booster response at a cost one fourth to one half that of a full 1 ml dose of vaccine.

  6. 48 CFR 52.247-65 - F.o.b. Origin, Prepaid Freight-Small Package Shipments.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false F.o.b. Origin, Prepaid... Text of Provisions and Clauses 52.247-65 F.o.b. Origin, Prepaid Freight—Small Package Shipments. As prescribed in 47.303-17(f), insert the following clause: F.o.b. Origin Prepaid Freight—Small Package...

  7. 48 CFR 552.211-75 - Preservation, Packaging and Packing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Preservation, Packaging....211-75 Preservation, Packaging and Packing. As prescribed in 511.204(b)(2), insert the following clause: Preservation, Packaging, and Packing (FEB 1996) Unless otherwise specified, all items shall be...

  8. 48 CFR 852.214-73 - Alternate packaging and packing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Alternate packaging and....214-73 Alternate packaging and packing. As prescribed in 814.201-6(b)(3), insert the following provision: Alternate Packaging and Packing (JAN 2008) The bidder's offer must clearly indicate the quantity...

  9. Low-profile fiber connector for co-packaged optics

    NASA Astrophysics Data System (ADS)

    Brusberg, Lars; DeJong, Michael; Butler, Douglas L.; Clark, Jeffrey S.; Sutton, Clifford G.

    2018-02-01

    We developed a small form factor connector that can be assembled on all four sides of a high-data switch package for fiber connectivity. This paper discusses a novel connector approach that has the potential to meet all co-packaging requirements including solder-reflow-compatibility, de-mateability, low insertion loss and state-of-the art FAU attach. The connector was attached to the PIC for performance evaluation. The average insertion loss across all eight fibers of the assembly was 1.77 dB, including the three optical interfaces: (1) MT-to-MT between connector and receptacle, (2) receptacle-to-PLC and (3) PIC-to-FAU. Also included is the propagation loss of the PIC waveguide. Optical return loss was measured to be -55 dB or lower.

  10. Comparison of four recombinant hepatitis B vaccines applied on an accelerated schedule in healthy adults.

    PubMed

    Hernández-Bernal, Francisco; Aguilar-Betancourt, Arístides; Aljovin, Virginia; Arias, Gloria; Valenzuela, Carmen; de Alejo, Karen Pérez; Hernández, Karina; Oquendo, Orcilia; Figueredo, Niurka; Figueroa, Nelvis; Musacchio, Alexis; Véliz, Gloria; García, Elizeth; Mollineda, Alina D; Juvier, Ana Isabel; Trujillo, Janette; Delahanty, Aurora; Ortega, D; Cinza, Z; González, Verena L Muzio

    2011-10-01

    A post-marketing, double blind, randomised, controlled clinical trial to assess the immunogenicity and safety profiles of four commercially available recombinant hepatitis B vaccines was performed. The vaccines included in this study were Heberbiovac-HB (®) (Heber Biotec S.A., Havana, Cuba), Euvax-B (®) (LG Chemical Ltd., Seoul, Korea), Hepavax-Gene (®)   (Greencross Vaccine Corp., Seoul, Korea), and Engerix-B (®) (GlaxoSmithKline Biologicals, Rixensart, Belgium). Vaccines were administered intramuscularly to healthy adults in three 20mg doses at monthly intervals (0 - 1 -  2 months). Four hundred volunteers aged 18 to 45 years (average age, 35 years) non-reactive for serological markers of hepatitis B virus infection were vaccinated. Volunteers were randomly assigned (ratio 1:1:1:1) to one of the four treatment groups. The antibody response (anti-HBs) was assessed at days 60, 90 and 365 post-vaccination using a commercial kit. The four vaccines showed to be safe and highly immunogenic. Similar seroprotection rates (anti-HBs ≥10 IU/L) about one month after application of the second and third dose were obtained for Engerix-B (®) , Hepavax-Gene (®) , Euvax-B (®) , and Heberbiovac-HB (®) vaccines 96.7%, 96.6%, 100%, 100% and 98.8%, 89.5%, 100%, 100%, respectively.. Heberbiovac-HB (®) vaccine achieved significantly higher geometric mean antibody titers (GMT) and rate of good and  hyper-responders at all time-points post-vaccination. The GMT on day 365 after full vaccination was significantly reduced in all groups compared to day 90, although Heberbiovac-HB (®) showed the highest anti-HBs GMT and good-responders rate. The four vaccines were well tolerated and poorly reactogenic. No serious adverse events were observed. This study confirms an overall good immune response and rapid priming for the  four vaccines in the course of an accelerated schedule, with higher anti-HBs geometric mean concentrations and better responses for Heberbiovac-HB (®) . [WHO primary Registry Number: RPCEC00000075].

  11. 48 CFR 552.211-89 - Non-manufactured wood packaging material for export.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Non-manufactured wood... and Clauses 552.211-89 Non-manufactured wood packaging material for export. As prescribed in 511.204(b)(4), insert the following clause: Non-Manufactured Wood Packaging Material for Export (JAN 2010) (a...

  12. 48 CFR 552.211-89 - Non-manufactured wood packaging material for export.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Non-manufactured wood... and Clauses 552.211-89 Non-manufactured wood packaging material for export. As prescribed in 511.204(b)(4), insert the following clause: Non-Manufactured Wood Packaging Material for Export (JAN 2010) (a...

  13. 48 CFR 552.211-89 - Non-manufactured wood packaging material for export.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Non-manufactured wood... and Clauses 552.211-89 Non-manufactured wood packaging material for export. As prescribed in 511.204(b)(4), insert the following clause: Non-Manufactured Wood Packaging Material for Export (JAN 2010) (a...

  14. 48 CFR 552.211-89 - Non-manufactured wood packaging material for export.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Non-manufactured wood... and Clauses 552.211-89 Non-manufactured wood packaging material for export. As prescribed in 511.204(b)(4), insert the following clause: Non-Manufactured Wood Packaging Material for Export (JAN 2010) (a...

  15. 48 CFR 552.211-89 - Non-manufactured wood packaging material for export.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Non-manufactured wood... and Clauses 552.211-89 Non-manufactured wood packaging material for export. As prescribed in 511.204(b)(4), insert the following clause: Non-Manufactured Wood Packaging Material for Export (JAN 2010) (a...

  16. 21 CFR 310.515 - Patient package inserts for estrogens.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Patient package inserts for estrogens. 310.515... package inserts for estrogens. (a) Requirement for a patient package insert. FDA concludes that the safe... patient package insert containing information concerning the drug's benefits and risks. An estrogen drug...

  17. Packaging of microwave integrated circuits operating beyond 100 GHz

    NASA Technical Reports Server (NTRS)

    Samoska, L.; Daniel, E.; Sokolov, V.; Sommerfeldt, S.; Bublitz, J.; Olson, K.; Gilbert, B.; Chow, D.

    2002-01-01

    Several methods of packaging high speed (75-330 GHz) InP HEMT MMIC devices are discussed. Coplanar wirebonding is presented with measured insertion loss of less than 0.5dB and return loss better than -17 dB from DC to 110 GHz. A motherboard/daughterboard packaging scheme is presented which supports minimum loss chains of MMICs using this coplanar wirebonding method. Split waveguide block packaging approaches are presented in G-band (140-220 GHz) with two types of MMIC-waveguide transitions: E-plane probe andantipodal finline.

  18. [The development and operation of a package inserts service system for electronic medical records].

    PubMed

    Yamada, Hidetoshi; Nishimura, Sachiho; Shimamori, Yoshimitsu; Sato, Seiji; Hayase, Yukitoshi

    2003-03-01

    To promote the appropriate use of pharmaceuticals and to prevent side effects, physicians need package inserts on medicinal drugs as soon as possible. A medicinal drug information service system was established for electronic medical records to speed up and increase the efficiency of package insert communications within a medical institution. Development of this system facilitates access to package inserts by, for example, physicians. The time required to maintain files of package inserts was shortened, and the efficiency of the drug information service increased. As a source of package inserts for this system, package inserts using a standard generalized markup language (SGML) form were used, which are accessible to the public on the homepage of the Organization for Pharmaceutical Safety and Research (OPSR). This study found that a delay occurred in communicating revised package inserts from pharmaceutical companies to the OPSR. Therefore a pharmaceutical department page was set up as part of the homepage of the medical institution for electronic medical records to shorten the delay in the revision of package inserts posted on the medicinal drug information service homepage of the OPSR. The usefulness of this package insert service system for electronic medical records is clear. For more effective use of this system based on the OPSR homepage pharmaceutical companies have been requested to provide quicker updating of package inserts.

  19. Readability assessment of package inserts of biological medicinal products from the European medicines agency website.

    PubMed

    Piñero-López, Ma Ángeles; Modamio, Pilar; Lastra, Cecilia F; Mariño, Eduardo L

    2014-07-01

    Package inserts that accompany medicines are a common source of information aimed at patients and should match patient abilities in terms of readability. Our objective was to determine the degree of readability of the package inserts for biological medicinal products commercially available in 2007 and compare them with the readability of the same package inserts in 2010. A total of 33 package inserts were selected and classified into five groups according to the type of medicine: monoclonal antibody-based products, cytokines, therapeutic enzymes, recombinant blood factors and other blood-related products, and recombinant hormones. The package inserts were downloaded from the European Medicines Agency website in 2007 and 2010. Readability was evaluated for the entire text of five of the six sections of the package inserts and for the 'Annex' when there was one. Three readability formulas were used: SMOG (Simple Measure of Gobbledygook) grade, Flesh-Kincaid grade level, and Szigriszt's perspicuity index. No significant differences were found between the readability results for the 2007 package inserts and those from 2010 according to any of the three readability indices studied (p>0.05). However, there were significant differences (p<0.05) between the readability scores of the sections of the package inserts in both 2007 and 2010. The readability of the package inserts was above the recommended sixth grade reading level (ages 11-12) and may lead to difficulties of understanding for people with limited literacy. All the sections should be easy to read and, therefore, the readability of the medicine package inserts studied should be improved.

  20. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 5 2014-04-01 2014-04-01 false Patient package inserts for oral contraceptives... Patient package inserts for oral contraceptives. (a) Requirement for a patient package insert. The safe and effective use of oral contraceptive drug products requires that patients be fully informed of the...

  1. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 5 2012-04-01 2012-04-01 false Patient package inserts for oral contraceptives... Patient package inserts for oral contraceptives. (a) Requirement for a patient package insert. The safe and effective use of oral contraceptive drug products requires that patients be fully informed of the...

  2. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 5 2013-04-01 2013-04-01 false Patient package inserts for oral contraceptives... Patient package inserts for oral contraceptives. (a) Requirement for a patient package insert. The safe and effective use of oral contraceptive drug products requires that patients be fully informed of the...

  3. [A research of letter color visibility in package insert information using simulator].

    PubMed

    Kamimura, Naoki; Kinoshita, Noriyuki; Onaga, Midori; Watanabe, Yurika; Ijuin, Kazushige; Shikamura, Yoshiaki; Negishi, Kenichi; Kaiho, Fusao; Ohta, Takafumi

    2012-01-01

    Package insert of pharmaceutical drug is one of the most prioritized information for pharmacists to secure safety of patients. However, the color of character, size, font and so on are various company by company product to product from a viewpoint of visibility. It may be cause a serious accident in case visibility is unclear, although it is the most important information. Moreover, package insert with high visibility is required for color vision defectives from a viewpoint of a universal design. Then, the authors selected the package insert which has the boxed warning in the ethical pharmaceutical currently stored mostly in the present health insurance pharmacy and quantified the red color using the color meter. We advocate the state of a suitable package insert from a viewpoint of a universal design, whether the red color is high visible or not for color vision defectives using simulator.

  4. [Research on Insufficient Information for Pharmaceutical Products].

    PubMed

    Tomita, Takashi

    2017-01-01

     Several issues concerning medicines remain unclear, including the availability of known, but not easily recognizable information. This review evaluates the mechanisms of side effects and the various risk indications included in package inserts. The results can be summarized as follows. 1) Short-term exposure to gatifloxacin significantly induced insulin secretion and increased the cytosolic Ca 2+ concentration of islet cells by augmenting extracellular Ca 2+ influx and its release from the endoplasmic reticulum. Alternatively, there was a decline in the cellular insulin level and reactivity to sulfonylurea after prolonged exposure. The insulin depletion was greater than that produced by other fluoroquinolones. 2) The elution of di(2-ethylhexyl)phthalate (DEHP) from the infusion set could be associated with the solubilizers in the injection medicines. The package inserts of several products containing polysorbate or ethanol had no warning about DEHP. Although there was a slight correlation between polysorbate content and descriptions on package inserts, the use of DEHP-containing devices was prohibited for some products, even with limited amounts of polysorbate. Therefore, the package insert statements should be reviewed to reflect appropriately the extent of DEHP elution. 3) Risk management plan consists of strategies to minimize the potential risks of medicines. One approach could be to introduce reminders on package inserts; however, of 268 potential risks associated with 81 products, 56 were not mentioned in package inserts. Because most postmarketing pharmacovigilance plans depend on spontaneous reporting by healthcare personnel, the descriptions on package inserts should be reexamined.

  5. Seal welded cast iron nuclear waste container

    DOEpatents

    Filippi, Arthur M.; Sprecace, Richard P.

    1987-01-01

    This invention identifies methods and articles designed to circumvent metallurgical problems associated with hermetically closing an all cast iron nuclear waste package by welding. It involves welding nickel-carbon alloy inserts which are bonded to the mating plug and main body components of the package. The welding inserts might be bonded in place during casting of the package components. When the waste package closure weld is made, the most severe thermal effects of the process are restricted to the nickel-carbon insert material which is far better able to accommodate them than is cast iron. Use of nickel-carbon weld inserts should eliminate any need for pre-weld and post-weld heat treatments which are a problem to apply to nuclear waste packages. Although the waste package closure weld approach described results in a dissimilar metal combination, the relative surface area of nickel-to-iron, their electrochemical relationship, and the presence of graphite in both materials will act to prevent any galvanic corrosion problem.

  6. The Use of Cigarette Package Inserts to Supplement Pictorial Health Warnings: An Evaluation of the Canadian Policy.

    PubMed

    Thrasher, James F; Osman, Amira; Abad-Vivero, Erika N; Hammond, David; Bansal-Travers, Maansi; Cummings, K Michael; Hardin, James W; Moodie, Crawford

    2015-07-01

    Canada is the first country in the world to require cigarette manufacturers to enclose package inserts to supplement the exterior pictorial health warning label (HWL). In June 2012, Canada implemented new HWL package inserts that include cessation tips accompanied by a pictorial image. This study aims to assess the extent to which adult smokers report reading the newly mandated HWL inserts and to see whether reading them is associated with making a quit attempt. Data were analyzed from an online consumer panel of Canadian adult smokers, aged 18-64 years. Five waves of data were collected between September 2012 and January 2014, separated by 4-months intervals (n = 1,000 at each wave). Logistic generalized estimating equation (GEE) models were estimated to assess correlates of reading inserts and whether doing so is associated with making a quit attempt by the subsequent wave. At each wave, between 26% and 31% of the sample reported having read HWL package inserts at least once in the prior month. Smokers who read them were more likely to be younger, female, have higher income, intend to quit, have recently tried to quit, and thought more frequently about health risks because of warning labels. In models that adjusted for these and other potential confounders, smokers who read the inserts a few times or more in the past month were more likely to make a quit attempt at the subsequent wave compared to smokers who did not read the inserts. HWL package inserts with cessation-related tips and messages appear to increase quit attempts made by smokers. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. A fully wafer-level packaged RF MEMS switch with low actuation voltage using a piezoelectric actuator

    NASA Astrophysics Data System (ADS)

    Park, Jae-Hyoung; Lee, Hee-Chul; Park, Yong-Hee; Kim, Yong-Dae; Ji, Chang-Hyeon; Bu, Jonguk; Nam, Hyo-Jin

    2006-11-01

    In this paper, a fully wafer-level packaged RF MEMS switch has been demonstrated, which has low operation voltage, using a piezoelectric actuator. The piezoelectric actuator was designed to operate at low actuation voltage for application to advanced mobile handsets. The dc contact type RF switch was packaged using the wafer-level bonding process. The CPW transmission lines and piezoelectric actuators have been fabricated on separate wafers and assembled together by the wafer-level eutectic bonding process. A gold and tin composite was used for eutectic bonding at a low temperature of 300 °C. Via holes interconnecting the electrical contact pads through the wafer were filled completely with electroplated copper. The fully wafer-level packaged RF MEMS switch showed an insertion loss of 0.63 dB and an isolation of 26.4 dB at 5 GHz. The actuation voltage of the switch was 5 V. The resonant frequency of the piezoelectric actuator was 38.4 kHz and the spring constant of the actuator was calculated to be 9.6 N m-1. The size of the packaged SPST (single-pole single-through) switch was 1.2 mm × 1.2 mm including the packaging sealing rim. The effect of the proposed package structure on the RF performance was characterized with a device having CPW through lines and vertical feed lines excluding the RF switches. The measured packaging loss was 0.2 dB and the return loss was 33.6 dB at 5 GHz.

  8. Deficiencies of product labeling directions for the preparation of radiopharmaceuticals.

    PubMed

    Hung, Joseph C; Ponto, James A; Gadient, Katie R; Frie, Julia A; Aksamit, Carolyn M; Enquist, Cassandra L; Carrels, Katie E

    2004-01-01

    To identify potential deficiencies in product labeling (package insert) instructions for the preparation of radiopharmaceuticals. Preparation instructions, which include both reconstitution and quality control (QC) directions, as stated in the package inserts were evaluated for all commercially available reconstituted radiopharmaceuticals. Reviews of the package inserts were initially performed by each author, and then all identified deficiencies were compiled and evaluated by all authors. The preparation scenario for each package insert evaluated was based on a centralized nuclear pharmacy operation assuming typical support personnel, standard operating equipment, and workload. The instructions as stated in each package insert for the preparation (including QC) were rated as inadequate if a satisfactory preparation could not be prepared by a nuclear pharmacist or physician when instructions were followed exactly. Identified deficiencies in package insert instructions for the preparation of radiopharmaceuticals fell into the following five categories: (1) absent or incomplete directions (especially with regard to QC procedures); (2) restrictive directions (e.g., specific requirement to use designated needles, chromatography solvents, counting devices), (3) inconsistent directions (e.g., different reconstituted volumes for the same final drug product, unworkable expiration times); (4) impractical directions (e.g., unrealistically low reconstituted activity limits, dangerously high number of radiolabeled particles); and (5) vague directions (e.g., use of the words "should," "may," "recommend"). Manufacturers' directions for the preparation of radiopharmaceuticals often contain deficiencies and should be viewed as standard guidance rather than as requirements. Just as physicians are permitted to use U.S. Food and Drug Administration (FDA)-approved drugs for off-label indications, nuclear pharmacists should be allowed to use alternative methods for preparing radiopharmaceuticals, provided those methods have been validated to be as good as the stated directions and that the nuclear pharmacists do not engage in activities that fall outside the normal practice of pharmacy. Manufacturers, FDA, nuclear pharmacists, and nuclear physicians should work together to address identified deficiencies in package insert directions.

  9. Microbial viability in preparations packaged for single use.

    PubMed

    Obayashi, Akiko; Oie, Shigeharu; Kamiya, Akira

    2003-05-01

    We evaluated microbial viability in preparations packaged for single use only which mandate that residual solution be discarded such as albumin and globulin preparations as blood products, preparations containing albumin (such as urokinase and interferon), fat emulsions, and a preparation containing fat emulsions (propofol). In most preparations, Serratia marcescens and Burkholderia cepacia proliferated rapidly at 30 degrees C. However, in globulin preparations containing 1-2.25% glycine to prevent protein degradation (Gamma-Venin P, Venilon-I, Globulin Injection, and Ahlbulin), no growth of S. marcescens and B. cepacia was detected over 24 h at 30 degrees C. For globulin preparations containing 1-2.25% glycine, the injunction to "Discard residual solution after the package has been used" in the package inserts can be revised to "It is possible to use residual solution within 24 h after the package has been used with storage in a cool place."

  10. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... used in total parenteral nutrition. 201.323 Section 201.323 Food and Drugs FOOD AND DRUG ADMINISTRATION... parenteral nutrition. (a) The aluminum content of large volume parenteral (LVP) drug products used in total parenteral nutrition (TPN) therapy must not exceed 25 micrograms per liter (µg/L). (b) The package insert of...

  11. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... used in total parenteral nutrition. 201.323 Section 201.323 Food and Drugs FOOD AND DRUG ADMINISTRATION... parenteral nutrition. (a) The aluminum content of large volume parenteral (LVP) drug products used in total parenteral nutrition (TPN) therapy must not exceed 25 micrograms per liter (µg/L). (b) The package insert of...

  12. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... used in total parenteral nutrition. 201.323 Section 201.323 Food and Drugs FOOD AND DRUG ADMINISTRATION... parenteral nutrition. (a) The aluminum content of large volume parenteral (LVP) drug products used in total parenteral nutrition (TPN) therapy must not exceed 25 micrograms per liter (µg/L). (b) The package insert of...

  13. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... used in total parenteral nutrition. 201.323 Section 201.323 Food and Drugs FOOD AND DRUG ADMINISTRATION... parenteral nutrition. (a) The aluminum content of large volume parenteral (LVP) drug products used in total parenteral nutrition (TPN) therapy must not exceed 25 micrograms per liter (µg/L). (b) The package insert of...

  14. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... used in total parenteral nutrition. 201.323 Section 201.323 Food and Drugs FOOD AND DRUG ADMINISTRATION... parenteral nutrition. (a) The aluminum content of large volume parenteral (LVP) drug products used in total parenteral nutrition (TPN) therapy must not exceed 25 micrograms per liter (µg/L). (b) The package insert of...

  15. Application of Au-Sn eutectic bonding in hermetic radio-frequency microelectromechanical system wafer level packaging

    NASA Astrophysics Data System (ADS)

    Wang, Qian; Choa, Sung-Hoon; Kim, Woonbae; Hwang, Junsik; Ham, Sukjin; Moon, Changyoul

    2006-03-01

    Development of packaging is one of the critical issues toward realizing commercialization of radio-frequency-microelectromechanical system (RF-MEMS) devices. The RF-MEMS package should be designed to have small size, hermetic protection, good RF performance, and high reliability. In addition, packaging should be conducted at sufficiently low temperature. In this paper, a low-temperature hermetic wafer level packaging scheme for the RF-MEMS devices is presented. For hermetic sealing, Au-Sn eutectic bonding technology at temperatures below 300°C is used. Au-Sn multilayer metallization with a square loop of 70 µm in width is performed. The electrical feed-through is achieved by the vertical through-hole via filling with electroplated Cu. The size of the MEMS package is 1 mm × 1 mm × 700 µm. The shear strength and hermeticity of the package satisfies the requirements of MIL-STD-883F. Any organic gases or contamination are not observed inside the package. The total insertion loss for the packaging is 0.075 dB at 2 GHz. Furthermore, the robustness of the package is demonstrated by observing no performance degradation and physical damage of the package after several reliability tests.

  16. [A comparative analysis of inner wrapping and package inserts for medicines containing Panax ginseng C. A. Meyer].

    PubMed

    Auricchio, Mariangela Tirico; Batistic-Longatto, Mônica Arcon; Nicoletti, Maria Aparecida

    2007-10-01

    The information provided on package inserts and inner wrapping of eight products containing Panax ginseng from different manufacturers was compared internally and checked against data from the scientific literature. The inserts included extensive text, containing abundant information on indications for use, but no scientific evidence in humans. All the inserts lacked information on potential adverse effects and drug interaction. There was no standardization as to dose regimens, particularly in relation to the dried extract and ginsenoside concentration. The eight inserts thus showed no concern over standardization, indication for usage, or possible side effects and drug interactions.

  17. Sensitivity for Diagnosing Group A Streptococcal Pharyngitis from Manufacturers is 10% Higher than Reported in Peer-Reviewed Publications.

    PubMed

    Vachhani, Raj; Patel, Toral; Centor, Robert M; Estrada, Carlos A

    2017-01-01

    Meta-analyses based on peer-reviewed publications report a sensitivity of approximately 85% for rapid antigen streptococcus tests to diagnose group A streptococcal (GAS) pharyngitis. Because these meta-analyses excluded package inserts, we examined the test characteristics of rapid antigen streptococcal tests and molecular methods that manufacturers report in their package inserts. We included tests available in the US market (Food and Drug Administration, period searched 1993-2015) and used package insert data to calculate pooled sensitivity and specificity. To examine quality, we used the Quality Assessment of Diagnostic Accuracy Studies-2. We excluded 26 tests having different trade names but identical methods and data. The study design was prospective in 41.7% (10 of 24). The pooled sensitivity of the most commonly used method, lateral flow/immunochromatographic, was 95% (95% confidence interval [CI] 94-96) and the pooled specificity was 98% (96-98); 7108 patients. The pooled sensitivity of the polymerase chain reaction or molecular methods was 98% (95% CI 96-98) and the pooled specificity was 96% (95% CI 95-97); 5685 patients. Package inserts include sponsored studies that overestimate the sensitivity of rapid tests to diagnose GAS pharyngitis by approximately 10%. Physicians should understand that package inserts overestimate diagnostic test utility; a negative test cannot be used to exclude GAS pharyngitis.

  18. 21 CFR 310.515 - Patient package inserts for estrogens.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Patient package inserts for estrogens. 310.515 Section 310.515 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE NEW DRUGS Requirements for Specific New Drugs or Devices § 310.515 Patient...

  19. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Patient package inserts for oral contraceptives. 310.501 Section 310.501 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the requirements of this section is misbranded under section 502 of the Federal Food, Drug, and...

  20. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Patient package inserts for oral contraceptives. 310.501 Section 310.501 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the requirements of this section is misbranded under section 502 of the Federal Food, Drug, and...

  1. Evaluating Documents: The Case of Patient Package Inserts. Technical Report No. 2.

    ERIC Educational Resources Information Center

    Krug, Robert E.

    To illustrate the types of factors that must be considered in evaluating public documents, this paper analyzes a number of possible outcomes resulting from one type of document, the patient package insert (PPI) designed to provide consumers of prescription drugs with information about the drugs. It first outlines the intended sequence for a PPI:…

  2. High-performance and high-reliability SOT-6 packaged diplexer based on advanced IPD fabrication techniques

    NASA Astrophysics Data System (ADS)

    Qiang, Tian; Wang, Cong; Kim, Nam-Young

    2017-08-01

    A diplexer offering the advantages of compact size, high performance, and high reliability is proposed on the basis of advanced integrated passive device (IPD) fabrication techniques. The proposed diplexer is developed by combining a third-order low-pass filter (LPF) and a third-order high-pass filter (HPF), which are designed on the basis of the elliptic function prototype low-pass filter. Primary components, such as inductors and capacitors, are designed and fabricated with high Q-factor and appropriate values, and they are subsequently used to construct a compact diplexer having a chip area of 900 μm × 1100 μm (0.009 λ0 × 0.011 λ0, where λ0 is the guided wavelength). In addition, a small-outline transistor (SOT-6) packaging method is adopted, and reliability tests (including temperature, humidity, vibration, and pressure) are conducted to guarantee long-term stability and commercial success. The packaged measurement results indicate excellent RF performance with insertion losses of 1.39 dB and 0.75 dB at operation bands of 0.9 GHz and 1.8 GHz, respectively. The return loss is lower than 10 dB from 0.5 GHz to 4.0 GHz, while the isolation is higher than 15 dB from 0.5 GHz to 3.0 GHz. Thus, it can be concluded that the proposed SOT-6 packaged diplexer is a promising candidate for GSM/CDMA applications. Synthetic solution of diplexer design, RF performance optimization, fabrication process, packaging, RF response measurement, and reliability test is particularly explained and analyzed in this work.

  3. Total internal reflection-evanescent coupler for fiber-to-waveguide integration of planar optoelectric devices.

    PubMed

    Lu, Zhaolin; Prather, Dennis W

    2004-08-01

    We present a method for parallel coupling from a single-mode fiber, or fiber ribbon, into a silicon-on-insulator waveguide for integration with silicon optoelectronic circuits. The coupler incorporates the advantages of the vertically tapered waveguides and prism couplers, yet offers the flexibility of planar integration. The coupler can be fabricated by use of either wafer polishing technology or gray-scale photolithography. When optimal coupling is achieved in our experimental setup, the coupler can be packaged by epoxy bonding to form a fiber-waveguide parallel coupler or connector. Two-dimensional electromagnetic calculation predicts a coupling efficiency of 77% (- 1.14-dB insertion loss) for a silicon-to-silicon coupler with a uniform tunnel layer. The coupling efficiency is experimentally achieved to be 46% (-3.4-dB insertion loss), excluding the loss in silicon and the reflections from the input surface and the output facet.

  4. Optical isolators for 2-micron fibre lasers

    NASA Astrophysics Data System (ADS)

    Stevens, Gary; Legg, Thomas H.; Shardlow, Peter

    2015-02-01

    We report on the development and testing of optical isolators for use in 2-micron fiber laser systems. A variety of potential Faraday rotator materials were characterised to identify the most suitable materials for use in the 1700-2100nm wavelength range. Isolators based on the three best performing materials were then developed and packaged as fiber-in, fiber-out and fiber-in, beam-out devices. The isolators were then tested in CW, pulsed and ultrafast laser systems. The three different designs produced different performance characteristics, but all designs demonstrated isolation >25dB and insertion losses of <1.2 dB.

  5. Fiber-optic coupling based on nonimaging expanded-beam optics.

    PubMed

    Moslehi, B; Ng, J; Kasimoff, I; Jannson, T

    1989-12-01

    We have fabricated and experimentally tested low-cost and mass-producible multimode fiber-optic couplers and connectors based on nonimaging beam-expanding optics and Liouville's theorem. Analysis indicates that a pair coupling loss of -0.25 dB can be achieved. Experimentally, we measured insertion losses as low as -0.38 dB. The beam expanders can be mass produced owing to the use of plastic injection-molding fabrication techniques and packaged in standard connector housings. This design is compatible with the fiber geometry and can yield highly stable coupling owing to its high tolerance for misalignments.

  6. Watermarking spot colors in packaging

    NASA Astrophysics Data System (ADS)

    Reed, Alastair; Filler, TomáÅ.¡; Falkenstern, Kristyn; Bai, Yang

    2015-03-01

    In January 2014, Digimarc announced Digimarc® Barcode for the packaging industry to improve the check-out efficiency and customer experience for retailers. Digimarc Barcode is a machine readable code that carries the same information as a traditional Universal Product Code (UPC) and is introduced by adding a robust digital watermark to the package design. It is imperceptible to the human eye but can be read by a modern barcode scanner at the Point of Sale (POS) station. Compared to a traditional linear barcode, Digimarc Barcode covers the whole package with minimal impact on the graphic design. This significantly improves the Items per Minute (IPM) metric, which retailers use to track the checkout efficiency since it closely relates to their profitability. Increasing IPM by a few percent could lead to potential savings of millions of dollars for retailers, giving them a strong incentive to add the Digimarc Barcode to their packages. Testing performed by Digimarc showed increases in IPM of at least 33% using the Digimarc Barcode, compared to using a traditional barcode. A method of watermarking print ready image data used in the commercial packaging industry is described. A significant proportion of packages are printed using spot colors, therefore spot colors needs to be supported by an embedder for Digimarc Barcode. Digimarc Barcode supports the PANTONE spot color system, which is commonly used in the packaging industry. The Digimarc Barcode embedder allows a user to insert the UPC code in an image while minimizing perceptibility to the Human Visual System (HVS). The Digimarc Barcode is inserted in the printing ink domain, using an Adobe Photoshop plug-in as the last step before printing. Since Photoshop is an industry standard widely used by pre-press shops in the packaging industry, a Digimarc Barcode can be easily inserted and proofed.

  7. 48 CFR 1852.211-70 - Packaging, handling, and transportation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... transportation. 1852.211-70 Section 1852.211-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND... and Clauses 1852.211-70 Packaging, handling, and transportation. As prescribed in 1811.404-70, insert the following clause: Packaging, Handling, and Transportation (SEPT 2005) (a) The Contractor shall...

  8. 48 CFR 1852.211-70 - Packaging, handling, and transportation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... transportation. 1852.211-70 Section 1852.211-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND... and Clauses 1852.211-70 Packaging, handling, and transportation. As prescribed in 1811.404-70, insert the following clause: Packaging, Handling, and Transportation (SEP 2005) (a) The Contractor shall...

  9. 48 CFR 1852.211-70 - Packaging, handling, and transportation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... transportation. 1852.211-70 Section 1852.211-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND... and Clauses 1852.211-70 Packaging, handling, and transportation. As prescribed in 1811.404-70, insert the following clause: Packaging, Handling, and Transportation (SEP 2005) (a) The Contractor shall...

  10. 48 CFR 1852.211-70 - Packaging, handling, and transportation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... transportation. 1852.211-70 Section 1852.211-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND... and Clauses 1852.211-70 Packaging, handling, and transportation. As prescribed in 1811.404-70, insert the following clause: Packaging, Handling, and Transportation (SEP 2005) (a) The Contractor shall...

  11. 21 CFR 516.165 - Records and reports.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... within 60 days thereafter. The report must contain data and information for the full reporting period..., include a summary of those changes and the holder's and distributor's current package labeling, including any package inserts. For large-size package labeling or large shipping cartons, submit a...

  12. 21 CFR 516.165 - Records and reports.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... within 60 days thereafter. The report must contain data and information for the full reporting period..., include a summary of those changes and the holder's and distributor's current package labeling, including any package inserts. For large-size package labeling or large shipping cartons, submit a...

  13. The NASA Electronic Parts and Packaging (NEPP) Program: Insertion of New Electronics Technologies

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2007-01-01

    This viewgraph presentation gives an overview of NASA Electronic Parts and Packaging (NEPP) Program's new electronics technology trends. The topics include: 1) The Changing World of Radiation Testing of Memories; 2) Even Application-Specific Tests are Costly!; 3) Hypothetical New Technology Part Qualification Cost; 4) Where we are; 5) Approaching FPGAs as a More Than a "Part" for Reliability; 6) FPGAs Beget Novel Radiation Test Setups; 7) Understanding the Complex Radiation Data; 8) Tracking Packaging Complexity and Reliability for FPGAs; 9) Devices Supporting the FPGA Need to be Considered; 10) Summary of the New Electronic Technologies and Insertion into Flight Programs Workshop; and 11) Highlights of Panel Notes and Comments

  14. ProtSqueeze: simple and effective automated tool for setting up membrane protein simulations.

    PubMed

    Yesylevskyy, Semen O

    2007-01-01

    The major challenge in setting up membrane protein simulations is embedding the protein into the pre-equilibrated lipid bilayer. Several techniques were proposed to achieve optimal packing of the lipid molecules around the protein. However, all of them possess serious disadvantages, which limit their applicability and discourage the users of simulation packages from using them. In the present work, we analyzed existing approaches and proposed a new procedure of protein insertion into the lipid bilayer, which is implemented in the ProtSqueeze software. The advantages of ProtSqueeze are as follows: (1) the insertion algorithm is simple, understandable, and controllable; (2) the software can work with virtually any simulation package on virtually any platform; (3) no modification of the source code of the simulation package is needed; (4) the procedure of insertion is as automated as possible; (5) ProtSqueeze is distributed for free under a general public license. In this work, we present the architecture and the algorithm of ProtSqueeze and demonstrate its usage in case studies.

  15. [Incremental effect and mechanism of cyclosporine on blood concentration of statins and statin package insert information in Japan].

    PubMed

    Hirata-Koizumi, Mutsuko; Saito, Mitsuo; Miyake, Shinji; Hasegawa, Ryuichi

    2005-01-01

    Cyclosporine is an indispensable immunosuppressant used in organ transplant patients, who frequently manifest hyperlipidemia. Statins, which are cholesterol-lowering agents, are often combined with cyclosporine in the treatment of hyperlipidemia of organ transplant patients. Since cyclosporine is a substrate and inhibitor of CYP3A4, researchers suspect that the immunosuppressant inhibits CYP3A4-mediated metabolism of statins, leading to an increase in statin plasma concentration and infrequently resulting in rhabdomyolysis. However, a number of clinical trials have shown cyclosporine to increase the plasma concentration of all developed statins, including those not metabolized by CYP3A4. Furthemore, recent mechanistic studies have shown organic anion transporting peptides (OATP) C to mediate the uptake of some statins and cyclosporine has been shown to inhibit the uptake via OATP-C in cultured cells. Therefore, the inhibition of hepatic uptake of statins is considered to be one of the mechanisms by which cyclosporine incrementally increases statin blood concentration. However, most current Japanese package inserts of statins give no information on change in pharmacokinetic parameters such as AUC and Cmax in the combined medication with cyclosporine. Furthermore, in the Japanese package inserts, it is either stated that cyclosporine inhibits CYP3A4-mediated metabolism or no comment is made on the mechanism. The package insert should properly provide available quantitative information on the change of pharmacokinetic parameters and the probable mechanism of action.

  16. Cigarette package inserts can promote efficacy beliefs and sustained smoking cessation attempts: A longitudinal assessment of an innovative policy in Canada

    PubMed Central

    Thrasher, James F.; Swayampakala, Kamala; Cummings, K. Michael; Hammond, David; Anshari, Dien; Krugman, Dean M.; Hardin, James W.

    2016-01-01

    Background In June 2012, Canada implemented new pictorial warnings on cigarette packages, along with package inserts with messages to promote response efficacy (i.e., perceived quitting benefits) and self-efficacy (i.e., confidence to quit). This study assessed smokers’ attention towards warnings and inserts and its relationship with efficacy beliefs, risk perceptions and cessation at follow-up. Methods Data were analysed in 2015 from a prospective online consumer panel of adult Canadian smokers surveyed every four months between September 2012 and September 2014. Generalized Estimating Equation models assessed associations between reading inserts, reading warnings and efficacy beliefs (self-efficacy, response efficacy), risk perceptions, quit attempts of any length, and sustained quit attempts (i.e., 30 days or more) at follow-up. Models adjusted for socio-demographics, smoking-related variables, and time-in-sample effects. Results Over the study period, reading warnings significantly decreased (p<0.0001) while reading inserts increased (p=0.004). More frequent reading of warnings was associated independently with stronger response efficacy (Boften/very often vs never=0.28, 95% CI: 0.11–0.46) and risk perceptions at follow-up (Boften/very often vs never=0.31, 95% CI: 0.06–0.56). More frequent reading of inserts was associated independently with stronger self-efficacy to quit at follow-up (Btwice or more vs none=0.30, 95% CI: 0.14–0.47), quit attempts (ORtwice or more vs none= 1.68, 95% CI: 1.28–2.19), and quit attempts lasting 30 days or longer (ORtwice or more vs none=1.48, 95% CI: 1.01 – 2.17). Conclusions More frequent reading of inserts was associated with self-efficacy to quit, quit attempts, and sustained quitting at follow-up, suggesting that inserts complement pictorial HWLs. PMID:26970037

  17. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  18. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  19. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  20. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  1. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  2. Conformity of package inserts information to regulatory requirements among selected branded and generic medicinal products circulating on the East African market.

    PubMed

    Sillo, Hiiti B; Masota, Nelson E; Kisoma, Sunday; Rago, Lembit; Mgoyela, Veronica; Kaale, Eliangiringa A

    2018-01-01

    Availability of correct and adequate information about medicines is an important aspect in ensuring rational use of medicines and hence facilitating safety and expected efficacy of medicines during therapy. Package inserts have proven to be a good source of information to the prescribers and patients whereby they have been useful in highlighting important information pertaining proper use and handling of the medicines. The present study was aimed at establishing the extent to which package inserts of medicines circulating on the markets of the East African Community (EAC) Partner States conform to medicines information requirements as established in the harmonized guidelines as well as national guidelines. A total of 99 package inserts from six (6) types of medicines namely Albendazole, Artemether/Lumefantrine (ALu), Ciprofloxacin, Paracetamol, Amoxicillin and Metronidazole were purposefully collected from three EAC Partner States: Kenya, Tanzania and Uganda. The medicines were selected based on their indications as first line treatments, high rates of utilization within the medicines supply system and their positions in treatment of diseases of public importance across EAC Partner States. The inserts were evaluated on the availability of information regarding fifteen (15) parameters as extracted from the EAC harmonized guidelines for registration of medicines. Moreover, comparisons were made between the percentage conformity of the branded versus generic products, markets from which the samples were collected, origin of the manufacturer and type of medicine. Majority (93.9-100%) of the medicines' package inserts highly conformed to the inclusion of the information regarding the description and composition of the medications, indications, dosage and methods of administration, warnings and precautions, contraindications and storage conditions. However, the information on handling and disposal, container package description, excipients used, clinical pharmacology of the medicines, and directions regarding overdose ranked the least in conformance with conformity ranging from 13.1-52.5%. The parameter with the lowest observed percentage conformity among the branded products scored 50% as compared to 10.8% among the generic products. Moreover, there was no significant difference (P<0.05) in the percentage conformity of the package inserts collected from each of the three Partner States as compared to the average from studied medicines. A generally good conformity was observed among medicines manufactured by European based manufacturers as compared to those based in Asia and EAC Partner States. In addition, PIs of Albendazole, Ciprofloxacin, Amoxicillin and Artemether/Lumefantrine did show overall high conformity across most of the product information requirements. Our study revealed the existence of a significant number of medicinal products circulating on the markets of EAC Partner States without necessary compliance with all product information requirements. We therefore recommend that NMRAs ensure thorough pre-market assessment of product information as well as strengthening their post marketing surveillance to ensure that medicines circulating on the market comply to medicines information requirements at all times. Emphasis should also be given to manufacturers on the importance of inclusion of appropriate and adequate product information for the safety of patients, including advocating for inclusion of patient-friendly and easy to understand medicines information.

  3. Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts.

    PubMed

    Gillet, Philippe; Maltha, Jessica; Hermans, Veerle; Ravinetto, Raffaella; Bruggeman, Cathrien; Jacobs, Jan

    2011-02-13

    The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed. Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n=40) and (ii) ambiguous labelling of the reading window (n=6). Buffer vial labels were lacking essential information (n=24) or were of poor quality (n=16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1-12.9) and user-unfriendly typography (median font size 8, range 5-10). Inadequacies included (i) no referral to biosafety (n=18), (ii) critical differences between depicted and real devices (n=8), (iii) figures with unrealistic colours (n=4), (iv) incomplete information about RDT line interpretations (n=31) and no data on test characteristics (n=8). Other problems included (i) kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n=4), (ii) not stating the identity of the pan-species antigen (n=2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups. Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information.

  4. Board-level optical clock signal distribution using Si CMOS-compatible polyimide-based 1- to 48-fanout H-tree

    NASA Astrophysics Data System (ADS)

    Wu, Linghui; Bihari, Bipin; Gan, Jianhua; Chen, Ray T.; Tang, Suning

    1998-08-01

    Si-CMOS compatible polymer-based waveguides for optoelectronic interconnects and packaging have been fabricated and characterized. A 1-to-48 fanout optoelectronic interconnection layer (OIL) structure based on Ultradel 9120/9020 for the high-speed massive clock signal distribution for a Cray T-90 supercomputer board has been constructed. The OIL employs multimode polymeric channel waveguides in conjunction with surface-normal waveguide output coupler and 1-to-2 splitter. A total insertion loss of 7.98 dB at 850 nm was measured experimentally.

  5. Hepatitis B Virus Core Gene Mutations Which Block Nucleocapsid Envelopment

    PubMed Central

    Koschel, Matthias; Oed, Daniela; Gerelsaikhan, Tudevdagwa; Thomssen, Reiner; Bruss, Volker

    2000-01-01

    Recently we generated a panel of hepatitis B virus core gene mutants carrying single insertions or deletions which allowed efficient expression of the core protein in bacteria and self-assembly of capsids. Eleven of these mutations were introduced into a eukaryotic core gene expression vector and characterized by trans complementation of a core-negative HBV genome in cotransfected human hepatoma HuH7 cells. Surprisingly, four mutants (two insertions [EFGA downstream of A11 and LDTASALYR downstream of R39] and two deletions [Y38-R39-E40 and L42]) produced no detectable capsids. The other seven mutants supported capsid formation and pregenome packaging/viral minus- and plus-strand-DNA synthesis but to different levels. Four of these seven mutants (two insertions [GA downstream of A11 and EHCSP downstream of P50] and two deletions [S44 and A80]) allowed virion morphogenesis and secretion. The mutant carrying a deletion of A80 at the tip of the spike protruding from the capsid was hepatitis B virus core antigen negative but wild type with respect to virion formation, indicating that this site might not be crucial for capsid-surface protein interactions during morphogenesis. The other three nucleocapsid-forming mutants (one insertion [LS downstream of S141] and two deletions [T12 and P134]) were strongly blocked in virion formation. The corresponding sites are located in the part of the protein forming the body of the capsid and not in the spike. These mutations may alter sites on the particle which contact surface proteins during envelopment, or they may block the appearance of a signal for the transport or the maturation of the capsid which is linked to viral DNA synthesis and required for envelopment. PMID:10590084

  6. Packaging double-helical DNA into viral capsids.

    PubMed

    LaMarque, Jaclyn C; Le, Thuc-Vy L; Harvey, Stephen C

    2004-02-15

    DNA packaging in bacteriophage P4 has been examined using a molecular mechanics model with a reduced representation containing one pseudoatom per turn of the double helix. The model is a discretized version of an elastic continuum model. The DNA is inserted piecewise into the model capsid, with the structure being reoptimized after each piece is inserted. Various optimization protocols were investigated, and it was found that molecular dynamics at a very low temperature (0.3 K) produces the optimal packaged structure. This structure is a concentric spool, rather than the coaxial spool that has been commonly accepted for so many years. This geometry, which was originally suggested by Hall and Schellman in 1982 (Biopolymers Vol. 21, pp. 2011-2031), produces a lower overall elastic energy than coaxial spooling. Copyright 2003 Wiley Periodicals, Inc.

  7. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment.

    PubMed

    Nornoo, Adwoa O; Jackson, Jonathan; Axtell, Samantha

    2017-03-25

    Objective. To determine whether there is a correlation between pharmacy students' scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking. Methods. The HSRT was administered to first-year pharmacy students during a critical-thinking course in the spring semester. In the same semester, a required package insert assignment was completed in a pharmacokinetics course. To determine whether there was a relationship between HSRT scores and grades on the assignment, a Spearman's rho correlation test was performed. Results. A very weak but significant positive correlation was found between students' grades on the assignment and their overall HSRT score (r=0.19, p <0.05), as well as deduction (a scale score of the HSRT; r=0.26, p <0.01). Conclusion. Based on a very weak but significant correlation to HSRT scores, this study demonstrated the potential of a package insert assignment to be used as one of the components to measure critical-thinking skills in pharmacy students.

  8. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment

    PubMed Central

    Jackson, Jonathan; Axtell, Samantha

    2017-01-01

    Objective. To determine whether there is a correlation between pharmacy students’ scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking. Methods. The HSRT was administered to first-year pharmacy students during a critical-thinking course in the spring semester. In the same semester, a required package insert assignment was completed in a pharmacokinetics course. To determine whether there was a relationship between HSRT scores and grades on the assignment, a Spearman’s rho correlation test was performed. Results. A very weak but significant positive correlation was found between students’ grades on the assignment and their overall HSRT score (r=0.19, p<0.05), as well as deduction (a scale score of the HSRT; r=0.26, p<0.01). Conclusion. Based on a very weak but significant correlation to HSRT scores, this study demonstrated the potential of a package insert assignment to be used as one of the components to measure critical-thinking skills in pharmacy students. PMID:28381884

  9. Pilot Fullerton uses water dispenser kit gun to rehydrate food package

    NASA Image and Video Library

    1982-03-30

    STS003-26-254 (30 March 1982) --- Astronaut Gordon Fullerton, STS-3 pilot, wearing communications kit assembly (ASSY) mini-headset (HDST), inserts the JSC water dispenser kit water gun in rehydratable plastic food (cereal) package to fill it with hot water. Photo credit: NASA

  10. BACCardI--a tool for the validation of genomic assemblies, assisting genome finishing and intergenome comparison.

    PubMed

    Bartels, Daniela; Kespohl, Sebastian; Albaum, Stefan; Drüke, Tanja; Goesmann, Alexander; Herold, Julia; Kaiser, Olaf; Pühler, Alfred; Pfeiffer, Friedhelm; Raddatz, Günter; Stoye, Jens; Meyer, Folker; Schuster, Stephan C

    2005-04-01

    We provide the graphical tool BACCardI for the construction of virtual clone maps from standard assembler output files or BLAST based sequence comparisons. This new tool has been applied to numerous genome projects to solve various problems including (a) validation of whole genome shotgun assemblies, (b) support for contig ordering in the finishing phase of a genome project, and (c) intergenome comparison between related strains when only one of the strains has been sequenced and a large insert library is available for the other. The BACCardI software can seamlessly interact with various sequence assembly packages. Genomic assemblies generated from sequence information need to be validated by independent methods such as physical maps. The time-consuming task of building physical maps can be circumvented by virtual clone maps derived from read pair information of large insert libraries.

  11. Health Instruction Packages: Specific Nursing Skills.

    ERIC Educational Resources Information Center

    Bates, Clarice; And Others

    Text, illustrations, and exercises are utilized in a set of five learning modules designed to instruct nursing students in a variety of clinical skills. The first module, "Down the Tube: Insertion of a Nasogastric Tube" by Clarice Bates, describes materials and procedures used to insert a nasogastric tube through the nose and esophagus…

  12. Dual Use of Packaging on the Moon: Logistics-2-Living

    NASA Technical Reports Server (NTRS)

    Howe, A. Scott; Howard, Robert

    2010-01-01

    This paper describes a modular packaging system for logistics that can be reconfigured into internal outfitting for a lunar outpost, including desks, chairs, partitions, cabinets, and radiation shielding. Logistics include clothes, equipment, food, and other consumables needed to sustain the crew for the duration of the mission. A significant mass penalty is required for the packaging and handling of logistics for re-supply of short to long-term space missions that must be brought out of the gravity well on a launch vehicle. Once the supplies have been exhausted, the packaging material is typically of no further use and is discarded. If a scheme can be developed that reuses the logistics packaging, the mass penalty can be reduced. In this research, a modular packaging system has been devised as a kit-of-parts that can be used for both handling logistics supplies, and then reconfigured into desks, chairs, partitions, cabinets, and radiation shielding. The system is derived from a standard International Space Station (ISS)-type Cargo Transfer Bag (CTB), using soft, unfoldable box-like containers with stiff metal inserts. The empty hydrogen-impregnated CTBs can be used as-is for cabinets, opened up for use as partitions, or draped over the habitat as layers of radiation shielding. Stiff metal inserts can be reconfigured into desks and other useful outfitting.

  13. Challenge with a hepatitis B vaccine in two cohorts of 4-7-year-old children primed with hexavalent vaccines: an open-label, randomised trial in Italy.

    PubMed

    Zanetti, Alessandro; Parlato, Antonino; Romanò, Luisa; Desole, Maria Giuseppina; Ferrera, Giuseppe; Giurdanella, Filippo; Zuliani, Massimo; Richard, Patrick; Thomas, Stéphane; Fiquet, Anne

    2012-08-24

    The anamnestic response to a challenge dose of vaccine can assess immune memory and protection against hepatitis B infection. This study investigated responses to a challenge dose of monovalent hepatitis B vaccine in children immunised with three doses of either Hexavac or Infanrix-Hexa during infancy. This open-label, randomised, controlled, four-arm study enrolled 410 healthy children aged 4-7 years who had received either Hexavac (n=201) or Infanrix-Hexa (n=209) at 3, 5 and 11 months of life. Children received a single intramuscular challenge dose of either hepatitis B vaccine, HBVaxPro (Hexavac, n=34; Infanrix-Hexa, n=28) or Engerix-B (Hexavac, n=167; Infanrix-Hexa, n=181). Hepatitis B surface antibody (anti-HBs) concentrations were measured before and 1 month after the challenge vaccine dose. The analysis was descriptive and no formal hypothesis was tested. One month post-challenge, 91.2% of children in the Hexavac group (95% confidence interval [CI] 86.3, 94.8) and 98.0% (95% CI 94.9, 99.4) in the Infanrix-Hexa group had anti-HBs concentrations ≥10 mIU/ml (primary endpoint). In a post hoc analysis, most children with pre-challenge anti-HBs concentration <10 mIU/ml achieved anti-HBs concentrations ≥10 mIU/ml (Hexavac group, 85.3% [95% CI 77.6, 91.2]; Infanrix-Hexa group, 91.9% [95% CI 78.1, 98.3]). Both challenge vaccines were well tolerated. These data suggest that immune memory persists for long-term (5 years) after a primary vaccination in infancy with a hexavalent vaccine (Hexavac or Infanrix-Hexa). Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program

    NASA Astrophysics Data System (ADS)

    Fayette, Daniel F.; Speicher, Patricia; Stoklosa, Mark J.; Evans, Jillian V.; Evans, John W.; Gentile, Mike; Pagel, Chuck A.; Hakim, Edward

    1993-08-01

    A joint military-commercial effort to evaluate multichip module (MCM) structures is discussed. The program, Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH), has been designed to identify the failure mechanisms that are possible in MCM structures. The RELTECH test vehicles, technical assessment task, product evaluation plan, reliability modeling task, accelerated and environmental testing, and post-test physical analysis and failure analysis are described. The information obtained through RELTECH can be used to address standardization issues, through development of cost effective qualification and appropriate screening criteria, for inclusion into a commercial specification and the MIL-H-38534 general specification for hybrid microcircuits.

  15. Current oral contraceptive use instructions: an analysis of patient package inserts.

    PubMed

    Williams-Deane, M; Potter, L S

    1992-01-01

    Oral contraceptive use instructions contained in manufacturers' patient package inserts (PPIs) are often inconsistent or conflicting, both among manufacturers and among different brands and regimens from the same manufacturer. Instructions on what to do about missed pills are often incomplete or inadequate, as are instructions on backup contraceptive use when pills are missed. The format of many PPIs is confusing and makes instructions difficult to find and read. Comprehending the PPIs requires the user to read at a 10th-12th-grade level, far higher than the generally accepted 5th-6th grade level considered standard for health education materials.

  16. Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program

    NASA Technical Reports Server (NTRS)

    Fayette, Daniel F.; Speicher, Patricia; Stoklosa, Mark J.; Evans, Jillian V.; Evans, John W.; Gentile, Mike; Pagel, Chuck A.; Hakim, Edward

    1993-01-01

    A joint military-commercial effort to evaluate multichip module (MCM) structures is discussed. The program, Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH), has been designed to identify the failure mechanisms that are possible in MCM structures. The RELTECH test vehicles, technical assessment task, product evaluation plan, reliability modeling task, accelerated and environmental testing, and post-test physical analysis and failure analysis are described. The information obtained through RELTECH can be used to address standardization issues, through development of cost effective qualification and appropriate screening criteria, for inclusion into a commercial specification and the MIL-H-38534 general specification for hybrid microcircuits.

  17. Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts

    PubMed Central

    2011-01-01

    Background The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. Methods Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed. Results Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n = 40) and (ii) ambiguous labelling of the reading window (n = 6). Buffer vial labels were lacking essential information (n = 24) or were of poor quality (n = 16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1 - 12.9) and user-unfriendly typography (median font size 8, range 5 - 10). Inadequacies included (i) no referral to biosafety (n = 18), (ii) critical differences between depicted and real devices (n = 8), (iii) figures with unrealistic colours (n = 4), (iv) incomplete information about RDT line interpretations (n = 31) and no data on test characteristics (n = 8). Other problems included (i) kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n = 4), (ii) not stating the identity of the pan-species antigen (n = 2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups. Conclusion Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information. PMID:21314992

  18. An easy packaging hybrid optical element in grating based WDM application

    NASA Astrophysics Data System (ADS)

    Lan, Hsiao-Chin; Cheng, Chao-Chia; Wang, Chih-Ming; Chang, Jenq-Yang

    2005-08-01

    We developed a new optical element which integrates an off-axis diffractive grating and an on-axis refractive lens surface in a prism. With this optical element, the alignment tolerance can be improved by manufacturing technology of the grating based WDM device and is practicable for mass production. An 100-GHz 16-channel DWDM device which includes this optical element has been designed. Ray tracing and beam propagation method (BPM) simulations showed good performance on the insertion loss of 2.91+/-0.53dB and the adjacent cross talk of 58.02dB. The tolerance discussion for this DWDM device shows that this optical element could be practically achieved by either injection molding or the hot embossing method.

  19. Advanced large scale GaAs monolithic IF switch matrix subsystem

    NASA Technical Reports Server (NTRS)

    Ch'en, D. R.; Petersen, W. C.; Kiba, W. M.

    1992-01-01

    Attention is given to a novel chip design and packaging technique to overcome the limitations due to the high signal isolation requirements of advanced communications systems. A hermetically sealed 6 x 6 monolithic GaAs switch matrix subsystem with integral control electronics based on this technique is presented. An 0-dB insertion loss and 60-dB crosspoint isolation over a 3.5-to-6-GHz band were achieved. The internal controller portion of the switching subsystem provides crosspoint control via a standard RS-232 computer interface and can be synchronized with an external systems control computer. The measured performance of this advanced switching subsystem is fully compatible with relatively static 'switchboard' as well as dynamic TDMA modes of operation.

  20. Method of fabricating a microelectronic device package with an integral window

    DOEpatents

    Peterson, Kenneth A.; Watson, Robert D.

    2003-01-01

    A method of fabricating a microelectronic device package with an integral window for providing optical access through an aperture in the package. The package is made of a multilayered insulating material, e.g., a low-temperature cofired ceramic (LTCC) or high-temperature cofired ceramic (HTCC). The window is inserted in-between personalized layers of ceramic green tape during stackup and registration. Then, during baking and firing, the integral window is simultaneously bonded to the sintered ceramic layers of the densified package. Next, the microelectronic device is flip-chip bonded to cofired thick-film metallized traces on the package, where the light-sensitive side is optically accessible through the window. Finally, a cover lid is attached to the opposite side of the package. The result is a compact, low-profile package, flip-chip bonded, hermetically-sealed package having an integral window.

  1. Reliability enhancement of Ohmic RF MEMS switches

    NASA Astrophysics Data System (ADS)

    Kurth, Steffen; Leidich, Stefan; Bertz, Andreas; Nowack, Markus; Frömel, Jörg; Kaufmann, Christian; Faust, Wolfgang; Gessner, Thomas; Akiba, Akira; Ikeda, Koichi

    2011-02-01

    This contribution deals with capacitively actuated Ohmic switches in series single pole single throw (SPST) configuration for DC up to 4 GHz signal frequency (<0.5 dB insertion loss, 35 dB isolation) and in shunt switch SPST configuration for a frequency range from DC up to 80 GHz (<1.2 dB insertion loss, 18 dB isolation at 60 GHz). A novel high aspect ratio MEMS fabrication sequence in combination with wafer level packaging is applied for fabrication of the samples and allows for a relatively large actuation electrode area, and for high actuation force resulting in fast onresponse time of 10 μs and off-response time of 6 μs at less than 5 V actuation voltage. Large actuation electrode area and a particular design feature for electrode over travel and dynamic contact separation lead to high contact force in the closed state and to high force for contact separation to overcome sticking. The switch contacts, which are consisting of noble metal, are made in one of the latest process steps. This minimizes contamination of the contact surfaces by fabrication sequence residuals. A life time of 1 Billion switch cycles has been achieved. This paper covers design for reliability issues and reliability test methods using accelerated life time test. Different test methods are combined to examine electric and mechanical motion parameters as well as RF performance.

  2. Recommendations for the use of medications with continuous enteral nutrition.

    PubMed

    Wohlt, Paul D; Zheng, Lan; Gunderson, Shelly; Balzar, Sarah A; Johnson, Benjamin D; Fish, Jeffrey T

    2009-08-15

    Recommendations for the use of medications with continuous enteral nutrition are provided. A literature review was conducted to identify primary literature reporting medication interactions with continuous enteral nutrition. For medications without supporting literature, manufacturers were contacted for information. Package inserts for specific medications were also investigated for any information to help guide recommendations. If no specific recommendations were made by the pharmaceutical manufacturer or the package insert concerning administration of products with continuous enteral nutrition, a tertiary database was consulted. Recommendations were generated by a consensus of clinicians for those medications that lacked specific recommendations in the primary literature or from the pharmaceutical manufacturer. Documentation of medication interactions with continuous enteral nutrition and food was then collated along with specific recommendations on how to administer the medication with regard to continuous enteral nutrition. Recommendations were classified as strong (grade 1) or weak (grade 2). The quality of evidence was classified as high (grade A), moderate (grade B), or low (grade C). Forty-six medications commonly given to hospitalized patients were evaluated. Twenty-four medications had recommendations based on available data, and the remaining 22 medications had recommendations based on a consensus of clinicians. There was a lack of published data regarding drug-nutrient interactions for a majority of the drugs commonly administered to patients receiving continuous enteral nutrition. Clinicians should recognize potential drug-nutrient interactions and use available evidence to optimize patients' drug therapy.

  3. Testing Cessation Messages for Cigarette Package Inserts: Findings from a Best/Worst Discrete Choice Experiment

    PubMed Central

    Thrasher, James F.; Davis, Rachel E.; Popova, Lucy; Cho, Yoo Jin; Salloum, Ramzi G.; Louviere, Jordan; Hammond, David

    2018-01-01

    This study assessed smokers’ responses to different smoking cessation topics and imagery for cigarette package inserts. Adult smokers from Canada (n = 1000) participated in three discrete choice experiments (DCEs): DCE 1 assessed five cessation benefit topics and five imagery types; DCE 2 assessed five messages with tips to improve cessation success and five imagery types; DCE 3 assessed four reproductive health benefits of cessation topics and four imagery types. In each DCE, participants evaluated four or five sets of four inserts, selecting the most and least motivating (DCEs 1 & 3) or helpful (DCE 2) for quitting. Linear mixed models regressed choices on insert and smoker characteristics. For DCE 1, the most motivating messages involved novel disease topics and imagery of younger women. For DCE 2, topics of social support, stress reduction and nicotine replacement therapy were selected as most helpful, with no differences by imagery type. For DCE 3, imagery influenced choices more than topic, with imagery of a family or a mom and baby selected as most motivating. Statistically significant interactions for all three experiments indicated that the influence of imagery type on choices depended on the message topic. Messages to promote smoking cessation through cigarette pack inserts should consider specific combinations of message topic and imagery. PMID:29415523

  4. A Review of Patents for the Smart Packaging of Meat and Muscle-based Food Products.

    PubMed

    Holman, Benjamin; Kerry, Joseph P; Hopkins, David L

    2017-10-31

    Meat packaging once acted primarily as an inert barrier to protect its contents against contamination and this function has shifted. Packaging now includes complementary functions that improve product quality, longevity and customer/retail appeal. The devices and methods applied to achieve these functions may be categorised as smart packaging, which includes intelligent packaging, devised to monitor and communicate packaged content status, and active packaging, to provide passive adjustment of in-pack conditions from its interactions with the packaged meat. Smart packaging examples already available from recent patents include antimicrobial and antioxidant packaging coatings and inserts; sensors or indicators that identify spoilage and freshness; functional engineering customisations; improvements to packaging integrity; leak or tamper detectors; and, environmentally sustainable options. Together, these inventions respond to industry and customer demands for meat packaging and are therefore the focus of this review, in which we discuss their applications and limitations in meat packaging. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    "rsed" is an R package that contains tools for stream editing: manipulating text files by making insertions, replacements, deletions, substitutions, or commenting. It hails from the powerful Unix command, "sed". While the "rsed" package is not nearly as powerful as "see", it is much simpler to use. R programmers often write scripts that may require simple manipulation of text files. "rsed" addresses that need.

  6. Microstructure-Evolution and Reliability Assessment Tool for Lead-Free Component Insertion in Army Electronics

    DTIC Science & Technology

    2008-10-01

    provide adequate means for thermal heat dissipation and cooling. Thus electronic packaging has four main functions [1]: • Signal distribution which... dissipation , involving structural and materials consideration. • Mechanical, chemical and electromagnetic protection of components and... nature when compared to phenomenological models. Microelectronic packaging industry spends typically several months building and reliability

  7. Do package inserts reflect symptoms experienced in practice?: assessment using an automated phone pharmacovigilance system with varenicline and zolpidem in a primary care setting.

    PubMed

    Haas, Jennifer S; Amato, Mary; Marinacci, Lucas; Orav, E John; Schiff, Gordon D; Bates, David W

    2012-08-01

    While the US FDA maintains a voluntary reporting system, postmarketing adverse drug events (ADEs) are underreported, and this case report-based system does not allow accurate determination of incidence. The aim of the study was to assess the usefulness of an automated phone pharmacovigilance system for ambulatory patients by comparing systematically collected, patient-reported symptoms to reflect possible ADEs with those reported on the package inserts of two drugs with postmarketing safety concerns, varenicline and zolpidem. English-speaking adults who received a prescription for zolpidem (n = 370) or varenicline (n = 107) from a primary care physician at one of 11 participating clinics, and who participated in the pharmacovigilance system during 2008-2010, were included in the study. Patients were called approximately 4 weeks following their visit and asked to complete a standard script that asked about adherence and pre-specified symptoms. The main outcome measures were elicited rates of pre-specified symptoms or possible ADEs. Compared with the package insert, patients taking zolpidem were significantly (p < 0.001) more likely to report fatigue (9.0% vs 1.0%), itching (4.5% vs 1.0%) and muscle aches (5.6% vs 1.0%). Elicited rates of depression and hallucination were similar to those reported in the package insert. Patients taking varenicline were significantly more likely to report confusion (1.7% vs 0.1%), depression (3.4% vs 0.1%), fatigue (6.0% vs 1.0%), hallucinations (1.7% vs 0.1%), muscle aches (6.0% vs 1.0%) and sexual dysfunction (4.3% vs 0.1%). Automated phone pharmacovigilance can provide estimates of possible ADEs in clinical practice. In the case of varenicline, these data support some of the safety concerns that have come to light postmarketing, while others such as depression and hallucination related to zolpidem were not detected. These data highlight the potential value of, and innovative ways of collecting, information about possible ADEs directly from patients.

  8. Technical Note: Computer-Manufactured Inserts for Prosthetic Sockets

    PubMed Central

    Sanders, Joan E.; McLean, Jake B.; Cagle, John C.; Gardner, David W.; Allyn, Katheryn J.

    2016-01-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant’s test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11 mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03 mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. PMID:27212209

  9. Reading about over-the-counter medications.

    PubMed

    Nabors, Laura A; Lehmkuhl, Heather D; Parkins, Irina S; Drury, Anna M

    2004-01-01

    Many adolescents and young adults purchase and use over-the-counter (OTC) medications, and some may take these medications without reading about how to use them. Most do read package inserts and labels to learn about the medication, but studies examining what influences label reading for youth are needed. This study assessed factors related to label reading for young people, including demographic variables (gender, health status) and the types of information they were seeking about the medication. Eight hundred and seventy-six high school and college students participated, and most reported reading labels or package inserts to learn about medications. Participants experiencing pain were more likely to read labels, except for those experiencing headaches who reported being less likely to read labels. When reading labels, participants were interested in information about side effects, ingredients, dosage instructions, and symptoms treated by the medication. Future research should examine whether youth take medications as directed and what factors make labels and inserts easier to read and understand.

  10. Jig Aligns Shadow Mask On CCD

    NASA Technical Reports Server (NTRS)

    Matus, Carlos V.

    1989-01-01

    Alignment viewed through microscope. Alignment jig positions shadow mask on charge-coupled device (CCD) so metal film deposited on it precisely. Allows CCD package to be inserted and removed without disturbing alignment of mask. Holds CCD packages securely and isolates it electrostatically while providing electrical contact to each of its pins. When alignment jig assembled with CCD, used to move mask under micrometer control.

  11. Serologic response to hepatitis B vaccination among lung transplantation candidates.

    PubMed

    Galar, Alicia; Engelson, Brian A; Kubiak, David W; Licona, Jose H; Boukedes, Steve; Goldberg, Hilary J; Baden, Lindsey R; Marty, Francisco M; Issa, Nicolas C

    2014-09-27

    Optimal hepatitis B (HBV) vaccination strategies for lung transplantation (LT) candidates are not well established. LT candidates with negative anti-HBs and anti-HBc antibody titers at baseline who received standard-dose HBV vaccination (Recombivax-HB 10 mcg/mL or Engerix-B 20 mcg/mL) administered at months 0, 1, and 6 or an accelerated vaccination schedule on days 0, 7 to 14, and 21 to 28 between June 1988 and October 2012 were studied. Patients who were more likely to undergo LT within 6 months of evaluation received the accelerated vaccination schedule starting in August 2009. Ninety-six HBV-seronegative patients who completed the vaccination series and had postvaccination anti-HBs titers available were identified. Median age was 60 years; 55.2% were female, and 92.7% were white. Underlying lung diseases included COPD (44.8%), idiopathic pulmonary fibrosis (22.9%), interstitial lung disease (15.6%), and cystic fibrosis (8.3%). The overall anti-HBs response rate was 54.2%. There was no significant difference in vaccine responses between accelerated and standard vaccination schedules (54.2% vs. 54.1%; P=1.0). Patients who received steroids or other immunosuppressants before transplantation had lower response rates compared with those who did not (38.9% vs. 63.3%; P=0.03). Better vaccination strategies to improve response rate are needed in this population. The accelerated HBV vaccination schedule elicited similar anti-HBs responses as the standard schedule and could be advantageous in this population, given current organ allocation practices, and it could allow repeat vaccination series for initial nonresponders before transplantation.

  12. Using PATIMDB to Create Bacterial Transposon Insertion Mutant Libraries

    PubMed Central

    Urbach, Jonathan M.; Wei, Tao; Liberati, Nicole; Grenfell-Lee, Daniel; Villanueva, Jacinto; Wu, Gang; Ausubel, Frederick M.

    2015-01-01

    PATIMDB is a software package for facilitating the generation of transposon mutant insertion libraries. The software has two main functions: process tracking and automated sequence analysis. The process tracking function specifically includes recording the status and fates of multiwell plates and samples in various stages of library construction. Automated sequence analysis refers specifically to the pipeline of sequence analysis starting with ABI files from a sequencing facility and ending with insertion location identifications. The protocols in this unit describe installation and use of PATIMDB software. PMID:19343706

  13. A Pre- and Post-Evaluation of Integrating Sustainability Curriculum by Inserting Okala Modules into an Interior Design Materials and Methods Course

    ERIC Educational Resources Information Center

    Schneiderman, Deborah; Freihoefer, Kara

    2012-01-01

    Purpose: The purpose of this paper is to examine the integration of Okala curriculum into Interior Design coursework. Okala, as a teaching package, is utilized extensively in industrial design education. However, this study examines the expansion and insertion of Okala modules in an existing interior design curriculum. The Okala modules included…

  14. Micromachined High Frequency PMN-PT/Epoxy 1-3 Composite Ultrasonic Annular Array

    PubMed Central

    Liu, Changgeng; Djuth, Frank; Li, Xiang; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk

    2013-01-01

    This paper reports the design, fabrication, and performance of miniature micromachined high frequency PMN-PT/epoxy 1-3 composite ultrasonic annular arrays. The PMN-PT single crystal 1-3 composites were made with micromachining techniques. The area of a single crystal pillar was 9 μm × 9 μm. The width of the kerf among pillars was ~ 5 μm and the kerfs were filled with a polymer. The composite thickness was 25 μm. A six-element annular transducer of equal element area of 0.2 mm2 with 16 μm kerf widths between annuli was produced. The aperture size the array transducer is about 1.5 mm in diameter. A novel electrical interconnection strategy for high density array elements was implemented. After the transducer was attached to the electric connection board and packaged, the array transducer was tested in a pulse/echo arrangement, whereby the center frequency, bandwidth, two-way insertion loss (IL), and cross talk between adjacent elements were measured for each annulus. The center frequency was 50 MHz and -6 dB bandwidth was 90%. The average insertion loss was 19.5 dB at 50 MHz and the crosstalk between adjacent elements was about -35 dB. The micromachining techniques described in this paper are promising for the fabrication of other types of high frequency transducers e.g. 1D and 2D arrays. PMID:22119324

  15. Mental models in risk assessment: informing people about drugs.

    PubMed

    Jungermann, H; Schütz, H; Thüring, M

    1988-03-01

    One way to communicate about the risks of drugs is through the use of package inserts. The problems associated with this medium of informing patients have been investigated by several researchers who found that people require information about drugs they are using, including extensive risk information, and that they are willing to take this information into account in their usage of drugs. But empirical results also show that people easily misinterpret the information given. A conceptual framework is proposed that might be used for better understanding the cognitive processes involved in such a type of risk assessment and communication. It is based on the idea that people develop, through experience, a mental model of how a drug works, which effects it might produce, that contraindications have to be considered, etc. This mental model is "run" when a specific package insert has been read and a specific question arises such as, for example, whether certain symptoms can be explained as normal or whether they require special attention and action. We argue that the mental model approach offers a useful perspective for examining how people understand package inserts, and consequently for improving their content and design. The approach promises to be equally useful for other aspects of risk analysis that are dependent upon human judgment and decision making, e.g., threat diagnosis and human reliability analysis.

  16. Technical note: Computer-manufactured inserts for prosthetic sockets.

    PubMed

    Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J

    2016-08-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. A Ka-Band Wide-Bandgap Solid-State Power Amplifier: Architecture Performance Estimates

    NASA Technical Reports Server (NTRS)

    Epp, L.; Khan, P.; Silva, A.

    2005-01-01

    Motivated by recent advances in wide-bandgap (WBG) gallium nitride (GaN) semiconductor technology, there is considerable interest in developing efficient solidstate power amplifiers (SSPAs) as an alternative to the traveling-wave tube amplifier (TWTA) for space applications. This article documents the results of a study to investigate power-combining technology and SSPA architectures that can enable a 120-W, 40 percent power-added efficiency (PAE) SSPA. Results of the study indicate that architectures based on at least three power combiner designs are likely to enable the target SSPA. The proposed architectures can power combine 16 to 32 individual monolithic microwave integrated circuits (MMICs) with >80 percent combining efficiency. This corresponds to MMIC requirements of 5- to 10-W output power and >48 percent PAE. For the three proposed architectures [1], detailed analysis and design of the power combiner are presented. The first architecture studied is based on a 16-way septum combiner that offers low loss and high isolation over the design band of 31 to 36 GHz. Analysis of a 2-way prototype septum combiner had an input match >25 dB, output match >30 dB, insertion loss <0.02 dB, and isolation >30 dB over the design band. A 16-way design, based on cascading this combiner in a binary fashion, is documented. The second architecture is based on a 24-way waveguide radial combiner. A prototype 24-way radial base was analyzed to have an input match >30 dB (under equal excitation of all input ports). The match of the mode transducer that forms the output of a radial combiner was found to be >27 dB. The functional bandwidth of the radial base and mode transducer, which together will form a radial combiner/divider, exceeded the design band. The third architecture employs a 32-way, parallel-plate radial combiner. Simulation results indicated an input match >24 dB, output match >22 dB, insertion loss <0.23 dB, and adjacent port isolation >20 dB over the design band. All three architectures utilize a low-loss MMIC amplifier module based on commercial MMIC packaging and a custom microstrip-to-rectangular-waveguide transition. The insertion loss of the module is expected to be 0.45 dB over the design band.

  18. Young adult smokers' perceptions of plain packs, numbered packs and pack inserts in Turkey: a focus group study.

    PubMed

    Mucan, Burcu; Moodie, Crawford

    2017-11-09

    The Turkish Government's 'National Tobacco Control Program 2015-2018' included plans to introduce plain packaging and also a ban on brand names on cigarette packs, allowing only assigned numbers on packs. We explored perceptions of these proposed measures, and also pack inserts with cessation messages, another novel way of using the packaging to communicate with consumers. Eight focus groups were conducted with 47 young adult smokers in Manisa and Kutahya (Turkey) in December 2016. Participants were shown three straight-edged plain cigarette packs, as required in Australia, and then three bevelled-edged plain packs, as permitted in the UK. They were then shown plain packs with numbers rather than brand names, and finally three pack inserts with messages encouraging quitting or offering tips on how to do so. Participants were asked about their perceptions of each. Plain packs were considered unappealing and off-putting, although the bevelled-edged packs were viewed more favourably than the straight-edged packs. Numbered packs were thought by some to diminish the appeal created by the brand name and potentially decrease interest among never smokers and newer smokers. Pack inserts were thought to have less of an impact than the on-pack warnings, but could potentially help discourage initiation and encourage cessation. That bevelled-edged plain packs were perceived more positively than straight-edged plain packs is relevant to countries planning to introduce plain packaging. The study provides a first insight into smokers' perceptions of a ban on brand names, which was perceived to reduce appeal among young people. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Evaluation of strategies to communicate harmful and potentially harmful constituent (HPHC) information through cigarette package inserts: a discrete choice experiment.

    PubMed

    Salloum, Ramzi G; Louviere, Jordan J; Getz, Kayla R; Islam, Farahnaz; Anshari, Dien; Cho, Yoojin; O'Connor, Richard J; Hammond, David; Thrasher, James F

    2017-07-13

    The US Food and Drug Administration (FDA) has regulatory authority to use inserts to communicate with consumers about harmful and potentially harmful constituents (HPHCs) in tobacco products; however, little is known about the most effective manner for presenting HPHC information. In a discrete choice experiment, participants evaluated eight choice sets, each of which showed two cigarette packages from four different brands and tar levels (high vs low), accompanied by an insert that included between-subject manipulations (ie, listing of HPHCs vs grouping by disease outcome and numeric values ascribed to HPHCs vs no numbers) and within-subject manipulations (ie, 1 of 4 warning topics; statement linking an HPHC with disease vs statement with no HPHC link). For each choice set, participants were asked: (1) which package is more harmful and (2) which motivates them to not smoke; each with a 'no difference' option. Alternative-specific logit models regressed choice on attribute levels. 1212 participants were recruited from an online consumer panel (725 18-29-year-old smokers and susceptible non-smokers and 487 30-64-year-old smokers). Participants were more likely to endorse high-tar products as more harmful than low-tar products, with a greater effect when numeric HPHC information was present. Compared with a simple warning statement, the statement linking HPHCs with disease encouraged quit motivation. Numeric HPHC information on inserts appears to produce misunderstandings that some cigarettes are less harmful than others. Furthermore, brief narratives that link HPHCs to smoking-related disease may promote cessation versus communications that do not explicitly link HPHCs to disease. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Polymer waveguide based hybrid opto-electric integration technology

    NASA Astrophysics Data System (ADS)

    Mao, Jinbin; Deng, Lingling; Jiang, Xiyan; Ren, Rong; Zhai, Yumeng; Wang, Jin

    2014-10-01

    While monolithic integration especially based on InP appears to be quite an expensive solution for optical devices, hybrid integration solutions using cheaper material platforms are considered powerful competitors because of the high freedom of design, yield optimization and relative cost-efficiency. Among them, the polymer planar-lightwave circuit (PLC) technology is regarded attractive as polymer offers the potential of fairly simple and low-cost fabrication, and of low-cost packaging. In our work, polymer PLC was fabricated by using the standard reactive ion etching (RIE) technique, while other active and passive devices can be integrated on the polymer PLC platform. Exemplary polymer waveguide devices was a 13-channel arrayed waveguide grating (AWG) chip, where the central channel cross-talk was below -30dB and the polarization dependent frequency shift was mitigated by inserting a half wave plate. An optical 900 hybrid was also realized with one 2×4 multi-mode interferometer (MMI). The excess insertion losses are below 4dB for the C-band, while the transmission imbalance is below 1.2dB. When such an optical hybrid was integrated vertically with mesa-type photodiodes, the responsivity of the individual PD was around 0.06 A/W, while the 3 dB bandwidth reaches 24 ~ 27 GHz, which is sufficient for 100Gbit/s receivers. Another example of the hybrid integration was to couple the polymer waveguides to fiber by applying fiber grooves, whose typical loss value was 0.2 dB per-facet over a broad spectral range from 1200-1600 nm.

  1. Developing targets for radiation transport experiments at the Omega laser facility

    DOE PAGES

    Capelli, Deanna; Charsley-Groffman, C. A.; Randolph, Randall Blaine; ...

    2017-07-13

    Targets have been developed to measure supersonic radiation transport in aerogel foams using absorption spectroscopy. The target consists of an aerogel foam uniformly doped with either titanium or scandium inserted into an undoped aerogel foam package. This creates a localized doped foam region to provide spatial resolution for the measurement. Development and characterization of the foams is a key challenge in addition to machining and assembling the two foams so they mate without gaps. The foam package is inserted into a beryllium sleeve and mounted on a gold hohlraum. The target is mounted to a holder created using additive manufacturingmore » and mounted on a stalk. As a result, the manufacturing of the components, along with assembly and metrology of the target are described here.« less

  2. Developing targets for radiation transport experiments at the Omega laser facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capelli, Deanna; Charsley-Groffman, C. A.; Randolph, Randall Blaine

    Targets have been developed to measure supersonic radiation transport in aerogel foams using absorption spectroscopy. The target consists of an aerogel foam uniformly doped with either titanium or scandium inserted into an undoped aerogel foam package. This creates a localized doped foam region to provide spatial resolution for the measurement. Development and characterization of the foams is a key challenge in addition to machining and assembling the two foams so they mate without gaps. The foam package is inserted into a beryllium sleeve and mounted on a gold hohlraum. The target is mounted to a holder created using additive manufacturingmore » and mounted on a stalk. As a result, the manufacturing of the components, along with assembly and metrology of the target are described here.« less

  3. Preliminary design report, Large Space Telescope OTA/SI Phase B study: High speed area photometer. [systems analysis

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A photometer is examined which combines several features from separate instruments into a single package. The design presented has both point and area photometry capability with provision for inserting filters to provide spectral discrimination. The electronics provide for photon counting mode for the point detectors and both photon counting and analog modes for the area detector. The area detector also serves as a target locating device for the point detectors. Topics discussed include: (1) electronic equipment requirements, (2) optical properties, (3) structural housing for the instrument, (4) motors and other mechanical components, (5) ground support equipment, and (6) environment control for the instrument. Engineering drawings and block diagrams are shown.

  4. Pilot Fullerton prepares meal on middeck

    NASA Image and Video Library

    1982-03-30

    STS003-26-253 (30 March 1982) --- Astronaut Gordon Fullerton, STS-3 pilot, wearing communications kit assembly (assy) mini-headset (HDST), prepares meal on middeck. Fullerton clips corner of rehydratable food (cereal) package with scissors. The opening will allow Fullerton to insert JSC water dispenser kit water gun in order to heat contents with hot water. Meal tray assembly is secured to forward middeck locker and holds additional food packages and beverage containers. Photo credit: NASA

  5. High-efficiency W-band hybrid integrated photoreceiver module using UTC-PD and pHEMT amplifier

    NASA Astrophysics Data System (ADS)

    Umezawa, T.; Katshima, K.; Kanno, A.; Akahane, K.; Matsumoto, A.; Yamamoto, N.; Kawanishi, T.

    2016-02-01

    A 100-GHz narrowband photoreceiver module integrated with a zero-bias operational uni-traveling-carrier photodiode (UTC-PD) and a GaAs-based pseudomorphic high-electron-mobility transistor (pHEMT) amplifier was fabricated and characterized. Both devices exhibited flat frequency response and outstanding overall performance. The UTC-PD showed a 3-dB bandwidth beyond 110 GHz while the pHEMT amplifier featured low power consumption and a gain of 24 dB over the 85-100 GHz range. A butterfly metal package equipped with a 1.0 mm (W) coaxial connector and a microstrip-coplanar waveguide conversion substrate was designed for low insertion loss and low return loss. The fabricated photoreceiver module demonstrated high conversion gain, a maximum output power of +9.5 dBm at 96 GHz, and DC-power consumption of 0.21 W.

  6. Ultra-compact 32 × 32 strictly-non-blocking Si-wire optical switch with fan-out LGA interposer.

    PubMed

    Tanizawa, Ken; Suzuki, Keijiro; Toyama, Munehiro; Ohtsuka, Minoru; Yokoyama, Nobuyuki; Matsumaro, Kazuyuki; Seki, Miyoshi; Koshino, Keiji; Sugaya, Toshio; Suda, Satoshi; Cong, Guangwei; Kimura, Toshio; Ikeda, Kazuhiro; Namiki, Shu; Kawashima, Hitoshi

    2015-06-29

    We demonstrate a 32 × 32 path-independent-insertion-loss optical path switch that integrates 1024 thermooptic Mach-Zehnder switches and 961 intersections on a small, 11 × 25 mm2 die. The switch is fabricated on a 300-mm-diameter silicon-on-insulator wafer by a complementary metal-oxide semiconductor-compatible process with advanced ArF immersion lithography. For reliable electrical packaging, the switch chip is flip-chip bonded to a ceramic interposer that arranges the electrodes in a 0.5-mm pitch land grid array. The on-chip loss is measured to be 15.8 ± 1.0 dB, and successful switching is demonstrated for digital-coherent 43-Gb/s QPSK signals. The total crosstalk of the switch is estimated to be less than -20 dB at the center wavelength of 1545 nm. The bandwidth narrowing caused by dimensional errors that arise during fabrication is discussed.

  7. A noise control package for vibrating screens1),2)

    PubMed Central

    Lowe, M. Jenae; Yantek, David S.; Yang, Junyi; Schuster, Kevin C.; Mechling, Jessie J.

    2015-01-01

    Hearing loss was the second-most common illness reported to the Mine Safety and Health Administration (MSHA) in 2009. Furthermore, between 2000 and 2010, 30% of all noise-related injury complaints reported to MSHA were for coal preparation plant employees. Previous National Institute for Occupational Safety and Health (NIOSH) studies have shown that vibrating screens are key noise sources to address in order to reduce coal preparation plant noise. In response, NIOSH researchers have developed a suite of noise controls for vibrating screens consisting of constrained layer damping (CLD) treatments, a tuned mechanism suspension, an acoustic enclosure, and spring inserts. Laboratory testing demonstrates that this noise control suite reduces the A-weighted sound power level of the vibrating screen by 6 dB. To provide a comparison to laboratory results and prove durability, field testing of two noise controls was performed on a vibrating screen in a working coal preparation plant. The spring inserts and CLD treatments were selected due to their ease of installation and practicability. Field testing of these controls yielded reductions that were comparable to laboratory results. PMID:26257468

  8. Development of Multifunctional Active Film and Its Application in Modified Atmosphere Packaging of Shiitake Mushrooms.

    PubMed

    Wang, Hong Jiang; An, Duck Soon; Lee, Dong Sun

    2016-09-01

    Agar-based films with multiple functions (CO 2 absorption, water vapor absorption, and antimicrobial activity) were developed, tested for their properties, and then applied to the packaging of fresh shiitake mushrooms as an insert label. The films were cast from an agar-based aqueous solution containing a dissolving plasticizer (glycerol), a CO 2 absorbent (sodium carbonate [SC] alone or a combination of SC and sodium glycinate [SC-SG]), and a volatile antimicrobial agent (carvacrol [CRV]). The agar of the film matrix is designed to serve as a water vapor absorbent. The multifunctional films tended to have poor mechanical properties, with a hard texture and an opaque and yellowish color. The CO 2 absorbent, either SC alone or SC-SG, affected CRV retention and release along with the CO 2 and water vapor absorption behavior. Both films (SC-CRV and SC-SG-CRV films) showed good inhibitory effects against Pseudomonas fluorescens and Saccharomyces cerevisiae . SC-CRV film had a higher and faster CO 2 absorption property, higher retention and extended release of CRV, and lower and slower water vapor absorption and was assessed to be better suited for use in shiitake mushroom packaging. The packaging in which the SC-CRV film with an appropriate amount of CRV was used as an insert label was able to generate the desired atmosphere and less moisture condensation inside the package, producing the best preservation of quality in terms of mushroom color, firmness, flavor score, and microbial counts after 6 days of storage at 10°C. A tailored modified atmosphere packaging system using multifunctional film would be useful in the preservation of CO 2 -sensitive fresh commodities.

  9. Do laboratories follow heart failure recommendations and guidelines and did we improve? The CARdiac MArker Guideline Uptake in Europe (CARMAGUE).

    PubMed

    Hammerer-Lercher, Angelika; Collinson, Paul; van Dieijen-Visser, Marja P; Pulkki, Kari; Suvisaari, Janne; Ravkilde, Jan; Stavljenic-Rukavina, Ana; Baum, Hannsjörg; Laitinen, Päivi

    2013-06-01

    Natriuretic peptides (NP) are well-established markers of heart failure (HF). During the past 5 years, analytical and clinical recommendations for measurement of these biomarkers have been published in guidelines. The aim of this follow-up survey was to investigate how well these guidelines for measurement of NP have been implemented in laboratory practice in Europe. Member societies of the European Federation of Clinical Chemistry and Laboratory Medicine were invited in 2009 to participate in a web-based audit questionnaire. The questionnaire requested information on type of tests performed, decision limits for HF, turn-around time and frequency of testing. There was a moderate increase (12%) of laboratories measuring NP compared to the initial survey in 2006. The most frequently used HF decision limits for B-type NP (BNP) and N-terminal BNP (NT-proBNP) were, respectively, 100 ng/L and 125 ng/L, derived from the package inserts in 55%. Fifty laboratories used a second decision limit. Age or gender dependent decision limits were applied in 10% (8.5% in 2006). The vast majority of laboratories (80%) did not have any criteria regarding frequency of testing, compared to 33% in 2006. The implementation of NP measurement for HF management was a slow process between 2006 and 2009 at a time when guidelines had just been established. The decision limits were derived from package insert information and literature. There was great uncertainty concerning frequency of testing which may reflect the debate about the biological variability which was not published for most of the assays in 2009.

  10. PDB file parser and structure class implemented in Python.

    PubMed

    Hamelryck, Thomas; Manderick, Bernard

    2003-11-22

    The biopython project provides a set of bioinformatics tools implemented in Python. Recently, biopython was extended with a set of modules that deal with macromolecular structure. Biopython now contains a parser for PDB files that makes the atomic information available in an easy-to-use but powerful data structure. The parser and data structure deal with features that are often left out or handled inadequately by other packages, e.g. atom and residue disorder (if point mutants are present in the crystal), anisotropic B factors, multiple models and insertion codes. In addition, the parser performs some sanity checking to detect obvious errors. The Biopython distribution (including source code and documentation) is freely available (under the Biopython license) from http://www.biopython.org

  11. 9 CFR 381.123 - Official inspection mark; official establishment number.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... label of a canned product, or on other packaging or labeling in the container, e.g., on aluminum pans... insert label placed under a transparent covering if clearly visible and legible and accompanied by the...

  12. 9 CFR 381.123 - Official inspection mark; official establishment number.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... label of a canned product, or on other packaging or labeling in the container, e.g., on aluminum pans... insert label placed under a transparent covering if clearly visible and legible and accompanied by the...

  13. 49 CFR 173.24b - Additional general requirements for bulk packagings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... packagings. 173.24b Section 173.24b Transportation Other Regulations Relating to Transportation PIPELINE AND... SHIPPERS-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Preparation of Hazardous Materials for Transportation § 173.24b Additional general requirements for bulk packagings. (a) Outage and filling limits. (1...

  14. Method of forming a package for MEMS-based fuel cell

    DOEpatents

    Morse, Jeffrey D; Jankowski, Alan F

    2013-05-21

    A MEMS-based fuel cell package and method thereof is disclosed. The fuel cell package comprises seven layers: (1) a sub-package fuel reservoir interface layer, (2) an anode manifold support layer, (3) a fuel/anode manifold and resistive heater layer, (4) a Thick Film Microporous Flow Host Structure layer containing a fuel cell, (5) an air manifold layer, (6) a cathode manifold support structure layer, and (7) a cap. Fuel cell packages with more than one fuel cell are formed by positioning stacks of these layers in series and/or parallel. The fuel cell package materials such as a molded plastic or a ceramic green tape material can be patterned, aligned and stacked to form three dimensional microfluidic channels that provide electrical feedthroughs from various layers which are bonded together and mechanically support a MEMS-based miniature fuel cell. The package incorporates resistive heating elements to control the temperature of the fuel cell stack. The package is fired to form a bond between the layers and one or more microporous flow host structures containing fuel cells are inserted within the Thick Film Microporous Flow Host Structure layer of the package.

  15. Method of forming a package for mems-based fuel cell

    DOEpatents

    Morse, Jeffrey D.; Jankowski, Alan F.

    2004-11-23

    A MEMS-based fuel cell package and method thereof is disclosed. The fuel cell package comprises seven layers: (1) a sub-package fuel reservoir interface layer, (2) an anode manifold support layer, (3) a fuel/anode manifold and resistive heater layer, (4) a Thick Film Microporous Flow Host Structure layer containing a fuel cell, (5) an air manifold layer, (6) a cathode manifold support structure layer, and (7) a cap. Fuel cell packages with more than one fuel cell are formed by positioning stacks of these layers in series and/or parallel. The fuel cell package materials such as a molded plastic or a ceramic green tape material can be patterned, aligned and stacked to form three dimensional microfluidic channels that provide electrical feedthroughs from various layers which are bonded together and mechanically support a MEMOS-based miniature fuel cell. The package incorporates resistive heating elements to control the temperature of the fuel cell stack. The package is fired to form a bond between the layers and one or more microporous flow host structures containing fuel cells are inserted within the Thick Film Microporous Flow Host Structure layer of the package.

  16. 49 CFR Appendix B to Part 173 - Procedure for Testing Chemical Compatibility and Rate of Permeation in Plastic Packaging and...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other... Plastic Packaging and Receptacles 1. The purpose of this procedure is to determine the chemical compatibility and permeability of liquid hazardous materials packaged in plastic packaging and receptacles...

  17. 49 CFR Appendix B to Part 173 - Procedure for Testing Chemical Compatibility and Rate of Permeation in Plastic Packaging and...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other... Plastic Packaging and Receptacles 1. The purpose of this procedure is to determine the chemical compatibility and permeability of liquid hazardous materials packaged in plastic packaging and receptacles...

  18. 49 CFR Appendix B to Part 173 - Procedure for Testing Chemical Compatibility and Rate of Permeation in Plastic Packaging and...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other... Plastic Packaging and Receptacles 1. The purpose of this procedure is to determine the chemical compatibility and permeability of liquid hazardous materials packaged in plastic packaging and receptacles...

  19. 49 CFR Appendix B to Part 173 - Procedure for Testing Chemical Compatibility and Rate of Permeation in Plastic Packaging and...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other... Plastic Packaging and Receptacles 1. The purpose of this procedure is to determine the chemical compatibility and permeability of liquid hazardous materials packaged in plastic packaging and receptacles...

  20. [Comparison of two different vaccination schemes against Hepatitis A and B in Mexican children and adolescents].

    PubMed

    González-Huezo, Ma Saraí; Sánchez-Avila, Francisco; García Mayol, Marcelino; Castro Narro, Graciela; Sixtos, Sara; Lisker-Melman, Mauricio; Kershenobich, David

    2003-01-01

    Development of multiple antigens in combined vaccines offers the advantages of reducing costs, increasing compliance and provides dual protection. Hepatitis A is an endemic disease in Mexico and hepatitis B, notwithstanding low prevalence, confers risk of progression to cirrhosis, hepatocellular carcinoma, and high medical costs in consequence. Determine immunogenicity and reactogenicity of a combined vaccine when compared with use of conventional vaccines simultaneously. The present study was a prospective, open, and randomized trial; 73 healthy children and adolescents were included, all with negative serologic markers. They were assigned to one of the following groups: Group 1, combined vaccine (n = 49) Twinrix (HAV 720 UE/HBV 20 micrograms), and group 2, separate vaccines (n = 24) Engerix B 20 micrograms/Havrix 720 UE. Both groups were given two-dose series at months 0 and 6. Geometric titles of antibody production (GMT) anti-HAV and anti-HBV were determined in months 1, 2, 6 and 7. Adverse reactions were registered during the study. No difference was observed between the two groups in age or gender. Immunogenicity anti-HAV: 100% of vaccines in both groups reached seroprotective levels (> or = 33 mUI/mL). Antibody titles in group 1 were three times higher than those in group 2 (9,696 mIU/mL vs. 3,940 mIU/mL [p = 0.003]) at the end of the study. Immunogenicity anti-HBV: All subjects in both groups reached seroprotective levels (> or = 10 mIU/mL) with similar antibody titles at the end of the study (group 1: 5,603 mIU/mL vs. group 2: 5,201 mIU/mL [p = 0.55 NS]). Reactogenicity: No serious adverse reactions were observed; main were local, and frequency and characteristics were similar in both groups. Seroprotective levels and reactogenicity obtained from use of a combined vaccine against hepatitis A/B are acceptable when compared with use of conventional vaccines administered separately.

  1. Functional Fluorescent Protein Insertions in Herpes Simplex Virus gB Report on gB Conformation before and after Execution of Membrane Fusion

    PubMed Central

    Gallagher, John R.; Atanasiu, Doina; Saw, Wan Ting; Paradisgarten, Matthew J.; Whitbeck, J. Charles; Eisenberg, Roselyn J.; Cohen, Gary H.

    2014-01-01

    Entry of herpes simplex virus (HSV) into a target cell requires complex interactions and conformational changes by viral glycoproteins gD, gH/gL, and gB. During viral entry, gB transitions from a prefusion to a postfusion conformation, driving fusion of the viral envelope with the host cell membrane. While the structure of postfusion gB is known, the prefusion conformation of gB remains elusive. As the prefusion conformation of gB is a critical target for neutralizing antibodies, we set out to describe its structure by making genetic insertions of fluorescent proteins (FP) throughout the gB ectodomain. We created gB constructs with FP insertions in each of the three globular domains of gB. Among 21 FP insertion constructs, we found 8 that allowed gB to remain membrane fusion competent. Due to the size of an FP, regions in gB that tolerate FP insertion must be solvent exposed. Two FP insertion mutants were cell-surface expressed but non-functional, while FP insertions located in the crown were not surface expressed. This is the first report of placing a fluorescent protein insertion within a structural domain of a functional viral fusion protein, and our results are consistent with a model of prefusion HSV gB constructed from the prefusion VSV G crystal structure. Additionally, we found that functional FP insertions from two different structural domains could be combined to create a functional form of gB labeled with both CFP and YFP. FRET was measured with this construct, and we found that when co-expressed with gH/gL, the FRET signal from gB was significantly different from the construct containing CFP alone, as well as gB found in syncytia, indicating that this construct and others of similar design are likely to be powerful tools to monitor the conformation of gB in any model system accessible to light microscopy. PMID:25233449

  2. 7 CFR Exhibit B to Subpart B of... - Housing Application Packaging Grant (HAPG) Fee Processing

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Processing B Exhibit B to Subpart B of Part 1944 Agriculture Regulations of the Department of Agriculture... Application Packaging Grants Pt. 1944, Subpt. B, Exh. B Exhibit B to Subpart B of Part 1944—Housing...) and (B) of this exhibit. Funds for all loan and/or grant application packages will be paid as follows...

  3. 7 CFR Exhibit B to Subpart B of... - Housing Application Packaging Grant (HAPG) Fee Processing

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Processing B Exhibit B to Subpart B of Part 1944 Agriculture Regulations of the Department of Agriculture... Application Packaging Grants Pt. 1944, Subpt. B, Exh. B Exhibit B to Subpart B of Part 1944—Housing...) and (B) of this exhibit. Funds for all loan and/or grant application packages will be paid as follows...

  4. 7 CFR Exhibit B to Subpart B of... - Housing Application Packaging Grant (HAPG) Fee Processing

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Processing B Exhibit B to Subpart B of Part 1944 Agriculture Regulations of the Department of Agriculture... Application Packaging Grants Pt. 1944, Subpt. B, Exh. B Exhibit B to Subpart B of Part 1944—Housing...) and (B) of this exhibit. Funds for all loan and/or grant application packages will be paid as follows...

  5. 7 CFR Exhibit B to Subpart B of... - Housing Application Packaging Grant (HAPG) Fee Processing

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Processing B Exhibit B to Subpart B of Part 1944 Agriculture Regulations of the Department of Agriculture... Application Packaging Grants Pt. 1944, Subpt. B, Exh. B Exhibit B to Subpart B of Part 1944—Housing...) and (B) of this exhibit. Funds for all loan and/or grant application packages will be paid as follows...

  6. 7 CFR Exhibit B to Subpart B of... - Housing Application Packaging Grant (HAPG) Fee Processing

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Processing B Exhibit B to Subpart B of Part 1944 Agriculture Regulations of the Department of Agriculture... Application Packaging Grants Pt. 1944, Subpt. B, Exh. B Exhibit B to Subpart B of Part 1944—Housing...) and (B) of this exhibit. Funds for all loan and/or grant application packages will be paid as follows...

  7. Ka-Band MMIC Subarray Technology Program (Ka-Mist)

    NASA Technical Reports Server (NTRS)

    Pottinger, W.

    1995-01-01

    Ka-band monolithic microwave integrated circuit (MMIC) arrays have been considered as having high potential for increasing the capability of space, aircraft, and land mobile communication systems in terms of scan performance, data rate, link margin, and flexibility while offering a significant reduction in size, weight, and power consumption. Insertion of MMIC technology into antenna systems, particularly at millimeter wave frequencies using low power and low noise amplifiers in closed proximity to the radiating elements, offers a significant improvement in the array transmit efficiency, receive system noise figure, and overall array reliability. Application of active array technology also leads to the use of advanced beamforming techniques that can improve beam agility, diversity, and adaptivity to complex signal environments. The objective of this program was to demonstrate the technical feasibility of the 'tile' array packaging architecture at EHF via the insertion of 1990 MMIC technology into a functional tile array or subarray module. The means test of this objective was to demonstrate and deliver to NASA a minimum of two 4 x 4 (16 radiating element) subarray modules operating in a transmit mode at 29.6 GHz. Available (1990) MMIC technology was chosen to focus the program effort on the novel interconnect schemes and packaging requirements rather than focusing on MMIC development. Major technical achievements of this program include the successful integration of two 4 x 4 subarray modules into a single antenna array. This 32 element array demonstrates a transmit EIRP of over 300 watts yielding an effective directive power gain in excess of 55 dB at 29.63 GHz. The array has been actively used as the transmit link in airborne/terrestrial mobile communication experiments accomplished via the ACTS satellite launched in August 1993.

  8. Effects Of Environmental And Operational Stresses On RF MEMS Switch Technologies For Space Applications

    NASA Technical Reports Server (NTRS)

    Jah, Muzar; Simon, Eric; Sharma, Ashok

    2003-01-01

    Micro Electro Mechanical Systems (MEMS) have been heralded for their ability to provide tremendous advantages in electronic systems through increased electrical performance, reduced power consumption, and higher levels of device integration with a reduction of board real estate. RF MEMS switch technology offers advantages such as low insertion loss (0.1- 0.5 dB), wide bandwidth (1 GHz-100 GHz), and compatibility with many different process technologies (quartz, high resistivity Si, GaAs) which can replace the use of traditional electronic switches, such as GaAs FETS and PIN Diodes, in microwave systems for low signal power (x < 500 mW) applications. Although the electrical characteristics of RF MEMS switches far surpass any existing technologies, the unknown reliability, due to the lack of information concerning failure modes and mechanisms inherent to MEMS devices, create an obstacle to insertion of MEMS technology into high reliability applications. All MEMS devices are sensitive to moisture and contaminants, issues easily resolved by hermetic or near-hermetic packaging. Two well-known failure modes of RF MEMS switches are charging in the dielectric layer of capacitive membrane switches and contact interface stiction of metal-metal switches. Determining the integrity of MEMS devices when subjected to the shock, vibration, temperature extremes, and radiation of the space environment is necessary to facilitate integration into space systems. This paper will explore the effects of different environmental stresses, operational life cycling, temperature, mechanical shock, and vibration on the first commercially available RF MEMS switches to identify relevant failure modes and mechanisms inherent to these device and packaging schemes for space applications. This paper will also describe RF MEMS Switch technology under development at NASA GSFC.

  9. Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/bottom Termination Components (QFN/BTC) Package Trends and Reliability

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2014-01-01

    Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

  10. Antimicrobial, antioxidant and sensory features of eugenol, carvacrol and trans-anethole in active packaging for organic ready-to-eat iceberg lettuce.

    PubMed

    Wieczyńska, Justyna; Cavoski, Ivana

    2018-09-01

    In this study, bio-based emitting sachets containing eugenol (EUG), carvacrol (CAR) and trans-anethole (ANT) were inserted into cellulose (CE) and polypropylene (PP) pillow packages of organic ready-to-eat (RTE) iceberg lettuce to investigate their functional features. EUG, CAR and ANT sachets in CE; and CAR in PP packages showed antimicrobial activities against coliforms (Δlog CFU g -1 of -1.38, -0.91, -0.93 and -0.93, respectively). EUG and ANT sachets in both packages reduced discoloration (ΔE of 9.5, 1.8, 9.4 and 5.6, respectively). ANT in both, and EUG only in PP packages induced biosynthesis of caffeoyl derivatives (C a T A , D i C a T A , D i C a Q A ), total phenolics and antioxidant activity (FRAP). Also, ANT and EUG in both packages improved overall freshness and odor. Principal component analysis separated ANT and EUG from CAR in both packages. The Pearson correlation confirmed that overall quality improvements were more pronounced by ANT inside the packages in comparison to EUG and CAR. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/Bottom Termination Components (QFN/BTC) Package Trends and Reliability

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2014-01-01

    Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

  12. Fuzzy based attitude controller for flexible spacecraft with on/off thrusters

    NASA Astrophysics Data System (ADS)

    Knapp, Roger G.; Adams, Neil J.

    A fuzzy-based attitude controller is designed for attitude control of a generic spacecraft with on/off thrusters. The controller is comprised of packages of rules dedicated to addressing different objectives (e.g., disturbance rejection, low fuel consumption, avoiding the excitation of flexible appendages, etc.). These rule packages can be inserted or removed depending on the requirements of the particular spacecraft and are parameterized based on vehicle parameters such as inertia or operational parameters such as the maneuvering rate. Individual rule packages can be 'weighted' relative to each other to emphasize the importance of one objective relative to another. Finally, the fuzzy controller and rule packages are demonstrated using the high-fidelity Space Shuttle Interactive On-Orbit Simulator (IOS) while performing typical on-orbit operations and are subsequently compared with the existing shuttle flight control system performance.

  13. Fuzzy based attitude controller for flexible spacecraft with on/off thrusters

    NASA Astrophysics Data System (ADS)

    Knapp, Roger Glenn

    1993-05-01

    A fuzzy-based attitude controller is designed for attitude control of a generic spacecraft with on/off thrusters. The controller is comprised of packages of rules dedicated to addressing different objectives (e.g., disturbance rejection, low fuel consumption, avoiding the excitation of flexible appendages, etc.). These rule packages can be inserted or removed depending on the requirements of the particular spacecraft and are parameterized based on vehicle parameters such as inertia or operational parameters such as the maneuvering rate. Individual rule packages can be 'weighted' relative to each other to emphasize the importance of one objective relative to another. Finally, the fuzzy controller and rule packages are demonstrated using the high-fidelity Space Shuttle Interactive On-Orbit Simulator (IOS) while performing typical on-orbit operations and are subsequently compared with the existing shuttle flight control system performance.

  14. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  15. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  16. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  17. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  18. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  19. A Tale of Two Citizens: A State Attorney General and a Hematologist Facilitate Translation of Research Into US Food and Drug Administration Actions—A SONAR Report

    PubMed Central

    Chen, Brian; Restaino, John; Norris, LeAnn; Xirasagar, Sudha; Qureshi, Zaina P.; McKoy, June M.; Lopez, Isaac S.; Trenery, Alyssa; Murday, Alanna; Kahn, Adam; Mattison, Donald R.; Ray, Paul; Sartor, Oliver; Bennett, Charles L.

    2012-01-01

    Purpose: Pharmaceutical safety is a public health issue. In 2005, the Connecticut Attorney General (AG) raised concerns over adverse drug reactions in off-label settings, noting that thalidomide was approved to treat a rare illness, but more than 90% of its use was off label. A hematologist had reported thalidomide with doxorubicin or dexamethasone was associated with venous thromboembolism (VTE) rates of 25%. We review US Food and Drug Administration (FDA) and manufacturer responses to a citizen petition filed to address these thalidomide safety issues. Methods: Case study. Results: The AG petitioned the FDA requesting thalidomide-related safety actions. Coincidentally, the manufacturer submitted a supplemental New Drug Approval (sNDA), requesting approval to treat multiple myeloma with thalidomide-dexamethasone. FDA safety officers reviewed the petition and the literature and noted that VTE risks with thalidomide were not appropriately addressed in the existing package insert. In the sNDA application, the manufacturer reported thalidomide-associated toxicities for multiple myeloma were primarily somnolence and neurotoxicity, and a proposed package insert did not focus on VTE risks. In October, the FDA informed the Oncology Drug Division that VTE risks with thalidomide were poorly addressed in the existing label. After reviewing this memorandum, an Oncology Drug Division reviewer informed the manufacturer that approval of the sNDA would be delayed until several thalidomide-associated VTE safety actions, including revisions of the package insert, were implemented. The manufacturer and FDA agreed on these actions, and the sNDA was approved. Conclusion: New approaches addressing off-label safety are needed. The conditions that facilitated the successful response to this citizen petition are uncommon. PMID:23598851

  20. A tale of two citizens: a State Attorney General and a hematologist facilitate translation of research into US Food and Drug Administration actions--a SONAR report.

    PubMed

    Chen, Brian; Restaino, John; Norris, LeAnn; Xirasagar, Sudha; Qureshi, Zaina P; McKoy, June M; Lopez, Isaac S; Trenery, Alyssa; Murday, Alanna; Kahn, Adam; Mattison, Donald R; Ray, Paul; Sartor, Oliver; Bennett, Charles L

    2012-11-01

    Pharmaceutical safety is a public health issue. In 2005, the Connecticut Attorney General (AG) raised concerns over adverse drug reactions in off-label settings, noting that thalidomide was approved to treat a rare illness, but more than 90% of its use was off label. A hematologist had reported thalidomide with doxorubicin or dexamethasone was associated with venous thromboembolism (VTE) rates of 25%. We review US Food and Drug Administration (FDA) and manufacturer responses to a citizen petition filed to address these thalidomide safety issues. Case study. The AG petitioned the FDA requesting thalidomide-related safety actions. Coincidentally, the manufacturer submitted a supplemental New Drug Approval (sNDA), requesting approval to treat multiple myeloma with thalidomide-dexamethasone. FDA safety officers reviewed the petition and the literature and noted that VTE risks with thalidomide were not appropriately addressed in the existing package insert. In the sNDA application, the manufacturer reported thalidomide-associated toxicities for multiple myeloma were primarily somnolence and neurotoxicity, and a proposed package insert did not focus on VTE risks. In October, the FDA informed the Oncology Drug Division that VTE risks with thalidomide were poorly addressed in the existing label. After reviewing this memorandum, an Oncology Drug Division reviewer informed the manufacturer that approval of the sNDA would be delayed until several thalidomide-associated VTE safety actions, including revisions of the package insert, were implemented. The manufacturer and FDA agreed on these actions, and the sNDA was approved. New approaches addressing off-label safety are needed. The conditions that facilitated the successful response to this citizen petition are uncommon.

  1. A Web-based searchable system to confirm magnetic resonance compatibility of implantable medical devices in Japan: a preliminary study.

    PubMed

    Fujiwara, Yasuhiro; Fujioka, Hitoshi; Watanabe, Tomoko; Sekiguchi, Maiko; Murakami, Ryuji

    2017-09-01

    Confirmation of the magnetic resonance (MR) compatibility of implanted medical devices (IMDs) is mandatory before conducting magnetic resonance imaging (MRI) examinations. In Japan, few such confirmation methods are in use, and they are time-consuming. This study aimed to develop a Web-based searchable MR safety information system to confirm IMD compatibility and to evaluate the usefulness of the system. First, MR safety information for intravascular stents and stent grafts sold in Japan was gathered by interviewing 20 manufacturers. These IMDs were categorized based on the descriptions available on medical package inserts as: "MR Safe," "MR Conditional," "MR Unsafe," "Unknown," and "No Medical Package Insert Available". An MR safety information database for implants was created based on previously proposed item lists. Finally, a Web-based searchable system was developed using this database. A questionnaire was given to health-care personnel in Japan to evaluate the usefulness of this system. Seventy-nine datasets were collected using information provided by 12 manufacturers and by investigating the medical packaging of the IMDs. Although the datasets must be updated by collecting data from other manufacturers, this system facilitates the easy and rapid acquisition of MR safety information for IMDs, thereby improving the safety of MRI examinations.

  2. Women's preferences for vaginal antimicrobial contraceptives. III. Choice of a formulation, applicator, and packaging.

    PubMed

    Hardy, E; Jiménez, A L; de Pádua, K S; Zaneveld, L J

    1998-10-01

    Novel vaginal formulations are under development to combat the increasing incidence of sexually transmitted diseases, including AIDS, and also unplanned pregnancies. A study was performed to determine women's preferences for different dosage forms (gel, cream, ovule/suppository, film, foam, tablet), width, length, and color of an applicator, and various types of packages. The study was conducted in Campinas, Brazil. A total of 635 women were interviewed, including both adolescents and adults and low and middle-high socioeconomic groups. The large majority of the women preferred a gel over a cream; both were preferred over the other methods. When asked which method they would not use, the film was most frequently identified, followed by the tablet and ovule. The primary reasons for selecting a particular dosage form were ease of use, absence of odor or the presence of a pleasant one, absence of color, and insertion with an applicator. The major reasons for not using a method were discomfort, "plastic" appearance, distrust of effectiveness, difficulty with insertion, messiness, and rigidity/hardness. The majority of the women liked the applicator shown. The prefilled single dose applicator was by far the preferred packaging. This information should aid in the development of consumer-friendly, vaginal formulations.

  3. Public judgments of information in a diazepam patient package insert.

    PubMed

    Fisher, S; Mansbridge, B; Lankford, D A

    1982-06-01

    As part of a larger study of the effects of giving patients written take-home information with prescription medications, a "patient package insert" (PPI) for diazepam was prepared based on content determined by "experts." This report compares the experts' judgments of what information should be included with judgments obtained from the public. Information judged to be most important for inclusion in a PPI was identified by having subjects sort cards containing facts about diazepam. Subjects who had previously used diazepam were no different in their judgments than inexperienced subjects. In general, there was a high degree of concordance between public and expert judgments and also a remarkably strong consensus across very different demographic samples. In those few instances of disagreement, the public attached even greater importance to warnings and "bad news" about diazepam than to information providing reassurances, benign general education, and "good news." To what extent patients would effectively use this information--whether conveyed by PPIs or alternative educational routes--must await empirical evaluation.

  4. Device-packaging method and apparatus for optoelectronic circuits

    DOEpatents

    Zortman, William A.; Henry, Michael David; Jarecki, Jr., Robert L.

    2017-04-25

    An optoelectronic device package and a method for its fabrication are provided. The device package includes a lid die and an active die that is sealed or sealable to the lid die and in which one or more optical waveguides are integrally defined. The active die includes one or more active device regions, i.e. integral optoelectronic devices or etched cavities for placement of discrete optoelectronic devices. Optical waveguides terminate at active device regions so that they can be coupled to them. Slots are defined in peripheral parts of the active dies. At least some of the slots are aligned with the ends of integral optical waveguides so that optical fibers or optoelectronic devices inserted in the slots can optically couple to the waveguides.

  5. Fuzzy based attitude controller for flexible spacecraft with on/off thrusters. M.S. Thesis - M.I.T., 1993

    NASA Technical Reports Server (NTRS)

    Knapp, Roger Glenn

    1993-01-01

    A fuzzy-based attitude controller is designed for attitude control of a generic spacecraft with on/off thrusters. The controller is comprised of packages of rules dedicated to addressing different objectives (e.g., disturbance rejection, low fuel consumption, avoiding the excitation of flexible appendages, etc.). These rule packages can be inserted or removed depending on the requirements of the particular spacecraft and are parameterized based on vehicle parameters such as inertia or operational parameters such as the maneuvering rate. Individual rule packages can be 'weighted' relative to each other to emphasize the importance of one objective relative to another. Finally, the fuzzy controller and rule packages are demonstrated using the high-fidelity Space Shuttle Interactive On-Orbit Simulator (IOS) while performing typical on-orbit operations and are subsequently compared with the existing shuttle flight control system performance.

  6. Establishment of MicroRNA delivery system by PP7 bacteriophage-like particles carrying cell-penetrating peptide.

    PubMed

    Sun, Yanli; Sun, Yanhua; Zhao, Ronglan

    2017-08-01

    MicroRNAs have great therapeutic potential in cancer and other diseases. However, their instability and low in vivo delivery efficiency limits their application. Recombinant PP7 bacteriophage-based virus-like particles (VLPs) could protect microRNAs against rapid degradation by RNase by packaging specific exogenous pre-microRNAs using the pac site. Insertion of a cell-penetrating peptide (CPP) into the AB-loop of VLPs could significantly improve the delivery efficiency of microRNAs into mammalian cells. Unlike other microRNA delivery methods (viral or non-viral vectors), recombinant PP7 VLPs carrying a CPP and microRNA could be efficiently expressed in Escherichia coli using the one-plasmid double expression system. Here we showed that PP7 VLPs carrying a CPP penetrated hepatoma SK-HEP-1 cells and delivered the pre-microRNA-23b, which was processed into a mature product within 24 h; a concentration of 10 nM was sufficient for the inhibition of hepatoma cell migration via the downregulation of liver-intestine cadherin expression. Furthermore, PP7 VLPs carrying a CPP and a pre-microRNA were not infectious, replicative, or cytotoxic. Therefore, recombinant PP7 VLPs can be used for simultaneous and targeted delivery of both microRNAs and peptides because of their ability to package specific exogenous RNA using the pac site and to display peptides. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  7. Intracellular Distribution of Capsid-Associated pUL77 of Human Cytomegalovirus and Interactions with Packaging Proteins and pUL93.

    PubMed

    Köppen-Rung, Pánja; Dittmer, Alexandra; Bogner, Elke

    2016-07-01

    DNA packaging into procapsids is a common multistep process during viral maturation in herpesviruses. In human cytomegalovirus (HCMV), the proteins involved in this process are terminase subunits pUL56 and pUL89, which are responsible for site-specific cleavage and insertion of the DNA into the procapsid via portal protein pUL104. However, additional viral proteins are required for the DNA packaging process. We have shown previously that the plasmid that encodes capsid-associated pUL77 encodes another potential player during capsid maturation. Pulse-chase experiments revealed that pUL77 is stably expressed during HCMV infection. Time course analysis demonstrated that pUL77 is expressed in the early late part of the infectious cycle. The sequence of pUL77 was analyzed to find nuclear localization sequences (NLSs), revealing monopartite NLSm at the N terminus and bipartite NLSb in the middle of pUL77. The potential NLSs were inserted into plasmid pHM829, which encodes a chimeric protein with β-galactosidase and green fluorescent protein. In contrast to pUL56, neither NLSm nor NLSb was sufficient for nuclear import. Furthermore, we investigated by coimmunoprecipitation whether packaging proteins, as well as pUL93, the homologue protein of herpes simplex virus 1 pUL17, are interaction partners of pUL77. The interactions between pUL77 and packaging proteins, as well as pUL93, were verified. We showed that the capsid-associated pUL77 is another potential player during capsid maturation of HCMV. Protein UL77 (pUL77) is a conserved core protein of HCMV. This study demonstrates for the first time that pUL77 has early-late expression kinetics during the infectious cycle and an intrinsic potential for nuclear translocation. According to its proposed functions in stabilization of the capsid and anchoring of the encapsidated DNA during packaging, interaction with further DNA packaging proteins is required. We identified physical interactions with terminase subunits pUL56 and pUL89 and another postulated packaging protein, pUL93, in infected, as well as transfected, cells. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  8. 22 CFR 125.6 - Certification requirements for exemptions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... LICENSES FOR THE EXPORT OF TECHNICAL DATA AND CLASSIFIED DEFENSE ARTICLES § 125.6 Certification requirements for exemptions. (a) To claim an exemption for the export of technical data under the provisions of.... Certifications consist of clearly marking the package or letter containing the technical data “22 CFR [insert...

  9. 22 CFR 125.6 - Certification requirements for exemptions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... Certifications consist of clearly marking the package or letter containing the technical data “22 CFR [insert... LICENSES FOR THE EXPORT OF TECHNICAL DATA AND CLASSIFIED DEFENSE ARTICLES § 125.6 Certification requirements for exemptions. (a) To claim an exemption for the export of technical data under the provisions of...

  10. 22 CFR 125.6 - Certification requirements for exemptions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... Certifications consist of clearly marking the package or letter containing the technical data “22 CFR [insert... LICENSES FOR THE EXPORT OF TECHNICAL DATA AND CLASSIFIED DEFENSE ARTICLES § 125.6 Certification requirements for exemptions. (a) To claim an exemption for the export of technical data under the provisions of...

  11. 22 CFR 125.6 - Certification requirements for exemptions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... Certifications consist of clearly marking the package or letter containing the technical data “22 CFR [insert... LICENSES FOR THE EXPORT OF TECHNICAL DATA AND CLASSIFIED DEFENSE ARTICLES § 125.6 Certification requirements for exemptions. (a) To claim an exemption for the export of technical data under the provisions of...

  12. 22 CFR 125.6 - Certification requirements for exemptions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... Certifications consist of clearly marking the package or letter containing the technical data “22 CFR [insert... LICENSES FOR THE EXPORT OF TECHNICAL DATA AND CLASSIFIED DEFENSE ARTICLES § 125.6 Certification requirements for exemptions. (a) To claim an exemption for the export of technical data under the provisions of...

  13. An Assessment of the Influence of the Industry Distribution Chain on the Oxygen Levels in Commercial Modified Atmosphere Packaged Cheddar Cheese Using Non-Destructive Oxygen Sensor Technology.

    PubMed

    O' Callaghan, Karen A M; Papkovsky, Dmitri B; Kerry, Joseph P

    2016-06-20

    The establishment and control of oxygen levels in packs of oxygen-sensitive food products such as cheese is imperative in order to maintain product quality over a determined shelf life. Oxygen sensors quantify oxygen concentrations within packaging using a reversible optical measurement process, and this non-destructive nature ensures the entire supply chain can be monitored and can assist in pinpointing negative issues pertaining to product packaging. This study was carried out in a commercial cheese packaging plant and involved the insertion of 768 sensors into 384 flow-wrapped cheese packs (two sensors per pack) that were flushed with 100% carbon dioxide prior to sealing. The cheese blocks were randomly assigned to two different storage groups to assess the effects of package quality, packaging process efficiency, and handling and distribution on package containment. Results demonstrated that oxygen levels increased in both experimental groups examined over the 30-day assessment period. The group subjected to a simulated industrial distribution route and handling procedures of commercial retailed cheese exhibited the highest level of oxygen detected on every day examined and experienced the highest rate of package failure. The study concluded that fluctuating storage conditions, product movement associated with distribution activities, and the possible presence of cheese-derived contaminants such as calcium lactate crystals were chief contributors to package failure.

  14. An Assessment of the Influence of the Industry Distribution Chain on the Oxygen Levels in Commercial Modified Atmosphere Packaged Cheddar Cheese Using Non-Destructive Oxygen Sensor Technology

    PubMed Central

    O’ Callaghan, Karen A.M.; Papkovsky, Dmitri B.; Kerry, Joseph P.

    2016-01-01

    The establishment and control of oxygen levels in packs of oxygen-sensitive food products such as cheese is imperative in order to maintain product quality over a determined shelf life. Oxygen sensors quantify oxygen concentrations within packaging using a reversible optical measurement process, and this non-destructive nature ensures the entire supply chain can be monitored and can assist in pinpointing negative issues pertaining to product packaging. This study was carried out in a commercial cheese packaging plant and involved the insertion of 768 sensors into 384 flow-wrapped cheese packs (two sensors per pack) that were flushed with 100% carbon dioxide prior to sealing. The cheese blocks were randomly assigned to two different storage groups to assess the effects of package quality, packaging process efficiency, and handling and distribution on package containment. Results demonstrated that oxygen levels increased in both experimental groups examined over the 30-day assessment period. The group subjected to a simulated industrial distribution route and handling procedures of commercial retailed cheese exhibited the highest level of oxygen detected on every day examined and experienced the highest rate of package failure. The study concluded that fluctuating storage conditions, product movement associated with distribution activities, and the possible presence of cheese-derived contaminants such as calcium lactate crystals were chief contributors to package failure. PMID:27331815

  15. Unexpected formal insertion of CO 2 into the C-Si bonds of a zinc compound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kemp, Richard A.; McGrew, Genette I.; Khatri, Pathik A.

    Reaction of [κ 2-PR 2C(SiMe 3)Py] 2Zn (R = Ph, 2a; iPr, 2b) with CO 2 affords the products of formal insertion at the C–Si bond, [κ 2-PR 2CC(O)O(SiMe 3)Py] 2Zn (R = Ph, 3a; iPr, 3b). Insertion product 3b was structurally characterized. As a result, the reaction appears to be a stepwise insertion and rearrangement of CO 2 based on kinetic data.

  16. Unexpected formal insertion of CO 2 into the C-Si bonds of a zinc compound

    DOE PAGES

    Kemp, Richard A.; McGrew, Genette I.; Khatri, Pathik A.; ...

    2015-09-08

    Reaction of [κ 2-PR 2C(SiMe 3)Py] 2Zn (R = Ph, 2a; iPr, 2b) with CO 2 affords the products of formal insertion at the C–Si bond, [κ 2-PR 2CC(O)O(SiMe 3)Py] 2Zn (R = Ph, 3a; iPr, 3b). Insertion product 3b was structurally characterized. As a result, the reaction appears to be a stepwise insertion and rearrangement of CO 2 based on kinetic data.

  17. 7 CFR Exhibit C to Subpart B of... - Requirements for Housing Application Packages

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 13 2011-01-01 2009-01-01 true Requirements for Housing Application Packages C Exhibit C to Subpart B of Part 1944 Agriculture Regulations of the Department of Agriculture (Continued... Packaging Grants Pt. 1944, Subpt. B, Exh. C Exhibit C to Subpart B of Part 1944—Requirements for Housing...

  18. 7 CFR Exhibit C to Subpart B of... - Requirements for Housing Application Packages

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 13 2012-01-01 2012-01-01 false Requirements for Housing Application Packages C Exhibit C to Subpart B of Part 1944 Agriculture Regulations of the Department of Agriculture (Continued... Packaging Grants Pt. 1944, Subpt. B, Exh. C Exhibit C to Subpart B of Part 1944—Requirements for Housing...

  19. Sealing Mustard Jars with Plastic Linerless Closures

    DTIC Science & Technology

    1985-10-01

    Recommendations 15 Literature cited 16 Appendices: A . Levels of Packaging 19 B. Value Engineering Correspondence 2 3 V ILLUSTRATIVE DATA Page...Analytical Progress Total Dietary Fiber Another Look, 1984, Vol 2,■No. 1, Minneapolis, MN 16 APPENDIXES A : Levels of Packaging B: Value...Engineering Correspondence 17 APPENDIX A : Levels of Packaging 19 APPENDIX A : Levels of Packaging Excerpt from: AR 700-15/NAVSUPINST 4030.28B/AFR 71~6

  20. 7 CFR Exhibit D to Subpart B of... - Designated Counties for Housing Application Packaging Grants

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 13 2010-01-01 2009-01-01 true Designated Counties for Housing Application Packaging... Application Packaging Grants Pt. 1944, Subpt. B, Exh. D Exhibit D to Subpart B of Part 1944—Designated Counties for Housing Application Packaging Grants ER25my05.036 ER25my05.037 ER25my05.038 ER25my05.039 [70...

  1. High-Tc superconductor coplanar waveguide filter

    NASA Technical Reports Server (NTRS)

    Chew, Wilbert; Bajuk, Louis J.; Cooley, Thomas W.; Foote, Marc C.; Hunt, Brian D.; Rascoe, Daniel L.; Riley, A. L.

    1991-01-01

    Coplanar waveguide (CPW) low-pass filters made of YBa2Cu3O(7-delta) (YBCO) on LaAlO3 substrates, with dimensions suited for integrated circuits, were fabricated and packaged. A complete filter gives a true idea of the advantages and difficulties in replacing thin-film metal with a high-temperature superconductor in a practical circuit. Measured insertion losses in liquid nitrogen were superior to the loss of a similar thin-film copper filter throughout the 0- to 9.5-GHz passband. These results demonstrate the performance of fully patterned YBCO in a practical CPW structure after sealing in a hermetic package.

  2. Apparatus and Method for Packaging and Integrating Microphotonic Devices

    NASA Technical Reports Server (NTRS)

    Nguyen, Hung (Inventor)

    2008-01-01

    An apparatus is disclosed that includes a carrier structure and an optical coupling arrangement. The carrier structure is made of a silicon material and allows for the packaging and integrating of microphotonic devices onto a single chip. The optical coupling mechanism enables laser light to be coupled into and out of a microphotonic resonant disk integrated on the carrier. The carrier provides first, second and third cavities that are dimensioned so as to accommodate the insertion and snug fitting of the microphotonic resonant disk and first and second prisms that are implemented by the optical coupling arrangement to accommodate the laser coupling.

  3. Agony of the ecstasy: report of five cases of MDMA smuggling.

    PubMed

    Low, V H S; Dillon, E K

    2005-10-01

    The international smuggling of illicit drugs by the ingestion or rectal insertion of drug-filled packages is recognized in the trafficking of heroin and cocaine. Customs authorities, with suspicion of such activities, presented five subjects. The legally allowed radiological examination comprising one supine abdominal radiograph was performed. Radiographic findings demonstrated the presence of multiple enteric oval, capsule-shaped packages of soft tissue density. This was confirmed following supervised evacuation of bowel contents induced by the administration of laxatives. Analysis of the concealed material identified ecstasy (methylenedioxymethamphetamine (MDMA)), a substance not previously reported as transported by this route.

  4. 10 CFR 71.91 - Records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... licensed material in each package, and the total quantity of each shipment; (5) For each item of irradiated... the shipment; (7) For fissile packages and for Type B packages, any special controls exercised; (8... determinations required by § 71.87 and by the conditions of the package approval. (b) Each certificate holder...

  5. 10 CFR 71.91 - Records.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... licensed material in each package, and the total quantity of each shipment; (5) For each item of irradiated... the shipment; (7) For fissile packages and for Type B packages, any special controls exercised; (8... determinations required by § 71.87 and by the conditions of the package approval. (b) Each certificate holder...

  6. 10 CFR 71.91 - Records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... licensed material in each package, and the total quantity of each shipment; (5) For each item of irradiated... the shipment; (7) For fissile packages and for Type B packages, any special controls exercised; (8... determinations required by § 71.87 and by the conditions of the package approval. (b) Each certificate holder...

  7. 10 CFR 71.91 - Records.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... licensed material in each package, and the total quantity of each shipment; (5) For each item of irradiated... the shipment; (7) For fissile packages and for Type B packages, any special controls exercised; (8... determinations required by § 71.87 and by the conditions of the package approval. (b) Each certificate holder...

  8. 21 CFR 520.1720b - Phenylbutazone granules.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... phenylbutazone per package or 1 gram of phenylbutazone per package. (b) Sponsor. See 000061 in § 510.600(c) for 8-gram package, see 059320 for 1-gram package. (c) NAS/NRC status. The conditions of use have been NAS... include effectiveness data specified by § 514.111 of this chapter, but may require bioequivalency and...

  9. 21 CFR 520.1720b - Phenylbutazone granules.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... phenylbutazone per package or 1 gram of phenylbutazone per package. (b) Sponsor. See 000061 in § 510.600(c) for 8-gram package, see 059320 for 1-gram package. (c) NAS/NRC status. The conditions of use have been NAS... include effectiveness data specified by § 514.111 of this chapter, but may require bioequivalency and...

  10. 21 CFR 520.1720b - Phenylbutazone granules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... phenylbutazone per package or 1 gram of phenylbutazone per package. (b) Sponsor. See 000061 in § 510.600(c) for 8-gram package, see 059320 for 1-gram package. (c) NAS/NRC status. The conditions of use have been NAS... include effectiveness data specified by § 514.111 of this chapter, but may require bioequivalency and...

  11. 21 CFR 520.1720b - Phenylbutazone granules.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... phenylbutazone per package or 1 gram of phenylbutazone per package. (b) Sponsor. See 000061 in § 510.600(c) for 8-gram package, see 059320 for 1-gram package. (c) NAS/NRC status. The conditions of use have been NAS... include effectiveness data specified by § 514.111 of this chapter, but may require bioequivalency and...

  12. 21 CFR 520.1720b - Phenylbutazone granules.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... phenylbutazone per package or 1 gram of phenylbutazone per package. (b) Sponsor. See 000061 in § 510.600(c) for 8-gram package, see 059320 for 1-gram package. (c) NAS/NRC status. The conditions of use have been NAS... include effectiveness data specified by § 514.111 of this chapter, but may require bioequivalency and...

  13. MODEL 9977 B(M)F-96 SAFETY ANALYSIS REPORT FOR PACKAGING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abramczyk, G; Paul Blanton, P; Kurt Eberl, K

    2006-05-18

    This Safety Analysis Report for Packaging (SARP) documents the analysis and testing performed on and for the 9977 Shipping Package, referred to as the General Purpose Fissile Package (GPFP). The performance evaluation presented in this SARP documents the compliance of the 9977 package with the regulatory safety requirements for Type B packages. Per 10 CFR 71.59, for the 9977 packages evaluated in this SARP, the value of ''N'' is 50, and the Transport Index based on nuclear criticality control is 1.0. The 9977 package is designed with a high degree of single containment. The 9977 complies with 10 CFR 71more » (2002), Department of Energy (DOE) Order 460.1B, DOE Order 460.2, and 10 CFR 20 (2003) for As Low As Reasonably Achievable (ALARA) principles. The 9977 also satisfies the requirements of the Regulations for the Safe Transport of Radioactive Material--1996 Edition (Revised)--Requirements. IAEA Safety Standards, Safety Series No. TS-R-1 (ST-1, Rev.), International Atomic Energy Agency, Vienna, Austria (2000). The 9977 package is designed, analyzed and fabricated in accordance with Section III of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code, 1992 edition.« less

  14. 21 CFR 357.152 - Package inserts for anthelmintic drug products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... discussion of the symptoms suggestive of pinworm infestation, including a statement that pinworms must be... the pinworm. (c) A commentary on the life cycle of the pinworm. (d) A commentary on the ways in which pinworms may be spread from person to person and hygienic procedures to follow to avoid such spreading. (e...

  15. 21 CFR 357.152 - Package inserts for anthelmintic drug products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... discussion of the symptoms suggestive of pinworm infestation, including a statement that pinworms must be... the pinworm. (c) A commentary on the life cycle of the pinworm. (d) A commentary on the ways in which pinworms may be spread from person to person and hygienic procedures to follow to avoid such spreading. (e...

  16. 21 CFR 357.152 - Package inserts for anthelmintic drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... discussion of the symptoms suggestive of pinworm infestation, including a statement that pinworms must be... the pinworm. (c) A commentary on the life cycle of the pinworm. (d) A commentary on the ways in which pinworms may be spread from person to person and hygienic procedures to follow to avoid such spreading. (e...

  17. 21 CFR 357.152 - Package inserts for anthelmintic drug products.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... discussion of the symptoms suggestive of pinworm infestation, including a statement that pinworms must be... the pinworm. (c) A commentary on the life cycle of the pinworm. (d) A commentary on the ways in which pinworms may be spread from person to person and hygienic procedures to follow to avoid such spreading. (e...

  18. 21 CFR 357.152 - Package inserts for anthelmintic drug products.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... discussion of the symptoms suggestive of pinworm infestation, including a statement that pinworms must be... the pinworm. (c) A commentary on the life cycle of the pinworm. (d) A commentary on the ways in which pinworms may be spread from person to person and hygienic procedures to follow to avoid such spreading. (e...

  19. Isolating USB connections in medical equipment.

    PubMed

    Broeders, Jan-Hein

    2009-01-01

    Although offering several benefits, the universal serial bus (USB) port has not been rapidly adopted for connecting medical equipment. This is because it could affect safety procedures, with equipment not operating isolated from the mains. To overcome this, a single package isolation device has been developed that can be inserted directly into the USB signal path.

  20. Standard Hardware Acquisition and Reliability Program's (SHARP's) efforts in incorporating fiber optic interconnects into standard electronic module (SEM) connectors

    NASA Astrophysics Data System (ADS)

    Riggs, William R.

    1994-05-01

    SHARP is a Navy wide logistics technology development effort aimed at reducing the acquisition costs, support costs, and risks of military electronic weapon systems while increasing the performance capability, reliability, maintainability, and readiness of these systems. Lower life cycle costs for electronic hardware are achieved through technology transition, standardization, and reliability enhancement to improve system affordability and availability as well as enhancing fleet modernization. Advanced technology is transferred into the fleet through hardware specifications for weapon system building blocks of standard electronic modules, standard power systems, and standard electronic systems. The product lines are all defined with respect to their size, weight, I/O, environmental performance, and operational performance. This method of defining the standard is very conducive to inserting new technologies into systems using the standard hardware. This is the approach taken thus far in inserting photonic technologies into SHARP hardware. All of the efforts have been related to module packaging; i.e. interconnects, component packaging, and module developments. Fiber optic interconnects are discussed in this paper.

  1. [Safety profile of heterologous serum produced by the Butantan Institute, in São Paulo-SP, Brazil, from 2012 to 2015].

    PubMed

    Gattás, Vera Lúcia; Braga, Patrícia Emília; Koike, Marcelo Eiji; Lucchesi, Maria Beatriz; Precioso, Alexander Roberto

    2017-01-01

    to describe the safety profile of the heterologous serum produced by the Butantan Institute (BI) of São Paulo-SP, Brazil. a descriptive study of adverse events (AEs) post-exposure to serum produced by the BI, encoded in the medical terminology of the Medical Dictionary for Regulatory Activities (MedDRA), and spontaneously reported to BI from 2012 to 2015. 52 individuals reported AEs, mainly related to Bothrops antivenom (n=11), diphtheria antitoxin (n=9) and unspecified snakebite serum (n=9); a mean of 3.2 AEs per individual was observed; among the total of 173 AEs, 63.0% were expected considering that they were described in the package insert; most of them were classified as skin and subcutaneous tissue disorders (30.6%); there were six deaths temporally related to the use of serum, but this association was discarded. in the studied period, the serum produced by the BI had no changes in their safety profiles, considering that the AEs were expected, according to the information previously described in the package insert.

  2. Cochlear Implant Electrode Array From Partial to Full Insertion in Non-Human Primate Model.

    PubMed

    Manrique-Huarte, Raquel; Calavia, Diego; Gallego, Maria Antonia; Manrique, Manuel

    2018-04-01

    To determine the feasibility of progressive insertion (two sequential surgeries: partial to full insertion) of an electrode array and to compare functional outcomes. 8 normal-hearing animals (Macaca fascicularis (MF)) were included. A 14 contact electrode array, which is suitably sized for the MF cochlea was partially inserted (PI) in 16 ears. After 3 months of follow-up revision surgery the electrode was advanced to a full insertion (FI) in 8 ears. Radiological examination and auditory testing was performed monthly for 6 months. In order to compare the values a two way repeated measures ANOVA was used. A p-value below 0.05 was considered as statistically significant. IBM SPSS Statistics V20 was used. Surgical procedure was completed in all cases with no complications. Mean auditory threshold shift (ABR click tones) after 6 months follow-up is 19 dB and 27 dB for PI and FI group. For frequencies 4, 6, 8, 12, and 16 kHz in the FI group, tone burst auditory thresholds increased after the revision surgery showing no recovery thereafter. Mean threshold shift at 6 months of follow- up is 19.8 dB ranging from 2 to 36dB for PI group and 33.14dB ranging from 8 to 48dB for FI group. Statistical analysis yields no significant differences between groups. It is feasible to perform a partial insertion of an electrode array and progress on a second surgical time to a full insertion (up to 270º). Hearing preservation is feasible for both procedures. Note that a minimal threshold deterioration is depicted among full insertion group, especially among high frequencies, with no statistical differences.

  3. Determination of Surface-Exposed, Functional Domains of Gonococcal Transferrin-Binding Protein A

    PubMed Central

    Yost-Daljev, Mary Kate; Cornelissen, Cynthia Nau

    2004-01-01

    The gonococcal transferrin receptor is composed of two distinct proteins, TbpA and TbpB. TbpA is a member of the TonB-dependent family of integral outer membrane transporters, while TbpB is lipid modified and thought to be peripherally surface exposed. We previously proposed a hypothetical topology model for gonococcal TbpA that was based upon computer predictions and similarity with other TonB-dependent transporters for which crystal structures have been determined. In the present study, the hemagglutinin epitope was inserted into TbpA to probe the surface topology of this protein and secondarily to test the functional impacts of site-specific mutagenesis. Twelve epitope insertion mutants were constructed, five of which allowed us to confirm the surface exposure of loops 2, 3, 5, 7, and 10. In contrast to the predictions set forth by the hypothetical model, insertion into the plug region resulted in an epitope that was surface accessible, while epitope insertions into two putative loops (9 and 11) were not surface accessible. Insertions into putative loop 3 and β strand 9 abolished transferrin binding and utilization, and the plug insertion mutant exhibited decreased transferrin-binding affinity concomitant with an inability to utilize it. Insertion into putative β strand 16 generated a mutant that was able to bind transferrin normally but that was unable to mediate utilization. Mutants with insertions into putative loops 2, 9, and 11 maintained wild-type binding affinity but could utilize only transferrin in the presence of TbpB. This is the first demonstration of the ability of TbpB to compensate for a mutation in TbpA. PMID:14977987

  4. Predicting Pharmacokinetic Stability by Multiple Oral Administration of Atypical Antipsychotics

    PubMed Central

    Aoki, Kazuo; Sakiyama, Yojiro; Ohnishi, Takashi; Sugita, Makoto

    2013-01-01

    Lower fluctuation, i.e., lower peak-to-trough plasma-concentration variation at steady-state pharmacokinetics, has several advantages for the treatment of schizophrenia with antipsychotics. The reduction of peak concentration can decrease the risk of dose-dependent side effects, such as extrapyramidal symptom and somnolence, and by contrast the increase in trough concentration can decrease the incidence of lack of efficacy due to subtherapeutic drug concentration. Using a one-compartment simulation technique with pharmacokinetic parameters of each atypical antipsychotic collected from package inserts, the fluctuation index was calculated. Among the antipsychotics, the indices varied from 0.018 to 1.9, depending on dosing regimens, formulations and several pharmacokinetic properties. The order of simulated fluctuation index is active-moiety aripiprazole (b.i.d.)

  5. Blood leak alarm interference by hydoxocobalamin is hemodialysis machine dependent.

    PubMed

    Sutter, M E; Clarke, M E; Cobb, J; Daubert, G P; Rathore, V S; Aston, L S; Poppenga, R H; Ford, J B; Owen, K P; Albertson, T E

    2012-12-01

    Hydroxocobalamin has been reported to interfere with the blood leak alarm on hemodialysis machines making it difficult to use this treatment modality after hydroxocobalamin infusion. The objective was to determine if this interference with hydroxocobalamin occurs across hemodialysis machines by different manufacturers. Additionally, we aimed to see if this represented a colorimetric interference alone or if it is the optical properties of hydroxocobalamin. Hydroxocobalamin was reconstituted per package insert. Food coloring was added to 0.9% saline to create the colors of the visual spectrum. Optical properties of absorbance and transmittance were measured. Hydroxocobalamin and the saline solutions were infused into the Fresenius 2008K™ and the Gambro Phoenix X36™ machines. Times were recorded from the start of the machine until the solution finished or the alarm triggered. When evaluating the Gambro Phoenix X36™ machine and dialysis circuit; the alarm did not trigger. In contrast, the blood leak alarm on the Fresenius 2008K™ machine was tripped by both the red solution and hydoxocobalamin infused per the package insert. The alarm stopped the machine between 128 and 132 seconds for the red solution and between 30 and 35 seconds with the hydroxocobalamin. Membranes of the circuits where the alarm tripped were examined and remained intact without blood. Results were validated on different machines with new circuits. Hydroxocobalamin infusion per package insert and the red saline solution prepared with Red Dye 40 both triggered the blood leak alarm and stopped the Fresenius 2008K™ machine. However, this was not true for the Gambro Phoenix X36™ machine as the alarm never triggered. The interference with the Fresenius 2008K™ appears colorimetric due to normal saline with Red Dye 40 triggering the alarm. We alert physicians to become familiar with the properties of individual dialysis machines prior to use of hydroxocobalamin. When facing difficulties with hemodialysis after the administration of hydroxocobalamin, consider attempting with a different manufactures machine or model if available or contact the manufacturer directly.

  6. 77 FR 67678 - Content Specifications and Shielding Evaluations for Type B Transportation Packages

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-13

    ...The U.S. Nuclear Regulatory Commission (NRC or the Commission) is issuing for public comment Draft Regulatory Issue Summary (RIS) 2012-XX, ``Content Specifications and Shielding Evaluations for Type B Transportation Packages.'' This RIS clarifies the NRC's use of staff guidance in NUREG-1609, ``Standard Review Plan for Transport Packages for Radioactive Material,'' for the review of content specifications and shielding evaluations included in the Certificates of Compliance (CoC) and safety analysis reports (SARs) for Type B transportation packages.

  7. 7 CFR Exhibit B-1 to Subpart I of... - Instructions for Preparation of Evaluation Report of Self-Help Technical Assistance Grants

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... Insert the number of equivalent units (EU) completed the first/second/third month of the quarter using steps 1, 2, and 3 of exhibit B-3. 8. Insert the number of EU's completed the second month of the quarter by using steps 1, 2, and 3 of exhibit B-3. 9. Insert the number of EU's completed the third month of...

  8. 7 CFR Exhibit B-1 to Subpart I of... - Instructions for Preparation of Evaluation Report of Self-Help Technical Assistance Grants

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... Insert the number of equivalent units (EU) completed the first/second/third month of the quarter using steps 1, 2, and 3 of exhibit B-3. 8. Insert the number of EU's completed the second month of the quarter by using steps 1, 2, and 3 of exhibit B-3. 9. Insert the number of EU's completed the third month of...

  9. Facile insertion of a cyclic alkyl(amino) carbene carbon into the B-B bond of diboron(4) reagents.

    PubMed

    Eichhorn, Antonius F; Kuehn, Laura; Marder, Todd B; Radius, Udo

    2017-10-24

    We report herein the room temperature insertion of the carbene carbon atom of the cyclic (alkyl)(amino) carbene cAAC Me into the B-B single bonds of the diboron(4) compounds B 2 pin 2 , B 2 cat 2 , B 2 neop 2 , and B 2 eg 2 (pin = pinacolato, cat = catecholato, neop = neopentylglycolato, eg = ethyleneglycolato).

  10. High performance millimeter-wave microstrip circulators and isolators

    NASA Technical Reports Server (NTRS)

    Shih, Ming; Pan, J. J.

    1990-01-01

    Millimeter wave systems, phased array antennas, and high performance components all require wideband circulators (and isolators) to perform diplexing and switching, to improve isolation and Voltage Standing Wave Ratio (VSWR), and to construct IMPATT diode reflection amplifiers. Presently, most of the millimeter-wave circulators and isolators are available in the configurations of waveguide or stripline, both of which suffer from the shortcomings of bulky size/weight, narrow bandwidth, and poor compatibility with monolithic millimeter-wave integrated circuits (MMIC). MMW microstrip circulators/isolators can eliminate or improve these shortcomings. Stub-tuned microstrip circulator configuration were developed utilizing the electromagnetic fields perturbation technique, the adhesion problems of microstrip metallization on new ferrite substrate were overcome, the fabrication, assembly, packaging techniques were improved, and then successfully designed, fabricated a Ka band circulator which has isolation and return loss of greater than 16dB, insertion loss less than 0.7dB. To assess the steady and reliable performance of the circulator, a temperature cycling test was done over the range of -20 to +50 C for 3 continuous cycles and found no significant impact or variation of circulator performance.

  11. [Chromosomal large fragment deletion induced by CRISPR/Cas9 gene editing system].

    PubMed

    Cheng, L H; Liu, Y; Niu, T

    2017-05-14

    Objective: Using CRISPR-Cas9 gene editing technology to achieve a number of genes co-deletion on the same chromosome. Methods: CRISPR-Cas9 lentiviral plasmid that could induce deletion of Aloxe3-Alox12b-Alox8 cluster genes located on mouse 11B3 chromosome was constructed via molecular clone. HEK293T cells were transfected to package lentivirus of CRISPR or Cas9 cDNA, then mouse NIH3T3 cells were infected by lentivirus and genomic DNA of these cells was extracted. The deleted fragment was amplified by PCR, TA clone, Sanger sequencing and other techniques were used to confirm the deletion of Aloxe3-Alox12b-Alox8 cluster genes. Results: The CRISPR-Cas9 lentiviral plasmid, which could induce deletion of Aloxe3-Alox12b-Alox8 cluster genes, was successfully constructed. Deletion of target chromosome fragment (Aloxe3-Alox12b-Alox8 cluster genes) was verified by PCR. The deletion of Aloxe3-Alox12b-Alox8 cluster genes was affirmed by TA clone, Sanger sequencing, and the breakpoint junctions of the CRISPR-Cas9 system mediate cutting events were accurately recombined, insertion mutation did not occur between two cleavage sites at all. Conclusion: Large fragment deletion of Aloxe3-Alox12b-Alox8 cluster genes located on mouse chromosome 11B3 was successfully induced by CRISPR-Cas9 gene editing system.

  12. Engineering multi-functional bacterial outer membrane vesicles as modular nanodevices for biosensing and bioimaging.

    PubMed

    Chen, Qi; Rozovsky, Sharon; Chen, Wilfred

    2017-07-04

    Outer membrane vesicles (OMVs) are proteoliposomes derived from the outer membrane and periplasmic space of many Gram-negative bacteria including E. coli as part of their natural growth cycle. Inspired by the natural ability of E. coli to sort proteins to both the exterior and interior of OMVs, we reported here a one-pot synthesis approach to engineer multi-functionalized OMV-based sensors for both antigen binding and signal generation. SlyB, a native lipoprotein, was used a fusion partner to package nanoluciferase (Nluc) within OMVs, while a previously developed INP-Scaf3 surface scaffold was fused to the Z-domain for antibody recruiting. The multi-functionalized OMVs were used for thrombin detection with a detection limit of 0.5 nM, comparable to other detection methods. Using the cohesin domains inserted between the Z-domain and INP, these engineered OMVs were further functionalized with a dockerin-tagged GFP for cancer cell imaging.

  13. Immune response to the hepatitis B antigen in the RTS,S/AS01 malaria vaccine, and co-administration with pneumococcal conjugate and rotavirus vaccines in African children: A randomized controlled trial.

    PubMed

    Valéa, Innocent; Adjei, Samuel; Usuf, Effua; Traore, Ousmane; Ansong, Daniel; Tinto, Halidou; Owusu Boateng, Harry; Leach, Amanda; Mwinessobaonfou Some, Athanase; Buabeng, Patrick; Vekemans, Johan; Nana, Louis Arnaud; Kotey, Amos; Vandoolaeghe, Pascale; Ouedraogo, Florence; Sambian, David; Lievens, Marc; Tahita, Marc Christian; Rettig, Theresa; Jongert, Erik; Lompo, Palpouguini; Idriss, Ali; Borys, Dorota; Ouedraogo, Sayouba; Prempeh, Frank; Habib, Md Ahsan; Schuerman, Lode; Sorgho, Hermann; Agbenyega, Tsiri

    2018-04-09

    The RTS,S/AS01 malaria vaccine (Mosquirix) reduces the incidence of Plasmodium falciparum malaria and is intended for routine administration to infants in Sub-Saharan Africa. We evaluated the immunogenicity and safety of 10-valent pneumococcal non-typeable Haemophilus influenzae protein D conjugate vaccine (PHiD-CV; Synflorix) and human rotavirus vaccine (HRV; Rotarix) when co-administered with RTS,S/AS01 ( www.clinicaltrials.gov NCT01345240) in African infants. 705 healthy infants aged 8-12 weeks were randomized to receive three doses of either RTS,S/AS01 or licensed hepatitis B (HBV; Engerix B) vaccine (control) co-administered with diphtheria-tetanus-acellular pertussis-Haemophilus influenzae type-b-conjugate vaccine (DTaP/Hib) and trivalent oral poliovirus vaccine at 8-12-16 weeks of age, because DTaP/Hib was not indicated before 8 weeks of age. The vaccination schedule can still be considered broadly applicable because it was within the age range recommended for EPI vaccination. PHiD-CV or HRV were either administered together with the study vaccines, or after a 2-week interval. Booster doses of PHiD-CV and DTaP/Hib were administered at age 18 months. Non-inferiority of anti-HBV surface antigen antibody seroprotection rates following co-administration with RTS,S/AS01 was demonstrated compared to the control group (primary objective). Pre-specified non-inferiority criteria were reached for PHiD-CV (for 9/10 vaccine serotypes), HRV, and aP antigens co-administered with RTS,S/AS01 as compared to HBV co-administration (secondary objectives). RTS,S/AS01 induced a response to circumsporozoite protein in all groups. Pain and low grade fever were reported more frequently in the PHiD-CV group co-administered with RTS,S/AS01 than PHiD-CV co-administered with HBV. No serious adverse events were considered to be vaccine-related. RTS,S/AS01 co-administered with pediatric vaccines had an acceptable safety profile. Immune responses to RTS,S/AS01 and to co-administered PHiD-CV, pertussis antigens and HRV were satisfactory.

  14. Influenza A and B Virus Intertypic Reassortment through Compatible Viral Packaging Signals

    PubMed Central

    Baker, Steven F.; Nogales, Aitor; Finch, Courtney; Tuffy, Kevin M.; Domm, William; Perez, Daniel R.; Topham, David J.

    2014-01-01

    ABSTRACT Influenza A and B viruses cocirculate in humans and together cause disease and seasonal epidemics. These two types of influenza viruses are evolutionarily divergent, and exchange of genetic segments inside coinfected cells occurs frequently within types but never between influenza A and B viruses. Possible mechanisms inhibiting the intertypic reassortment of genetic segments could be due to incompatible protein functions of segment homologs, a lack of processing of heterotypic segments by influenza virus RNA-dependent RNA polymerase, an inhibitory effect of viral proteins on heterotypic virus function, or an inability to specifically incorporate heterotypic segments into budding virions. Here, we demonstrate that the full-length hemagglutinin (HA) of prototype influenza B viruses can complement the function of multiple influenza A viruses. We show that viral noncoding regions were sufficient to drive gene expression for either type A or B influenza virus with its cognate or heterotypic polymerase. The native influenza B virus HA segment could not be incorporated into influenza A virus virions. However, by adding the influenza A virus packaging signals to full-length influenza B virus glycoproteins, we rescued influenza A viruses that possessed HA, NA, or both HA and NA of influenza B virus. Furthermore, we show that, similar to single-cycle infectious influenza A virus, influenza B virus cannot incorporate heterotypic transgenes due to packaging signal incompatibilities. Altogether, these results demonstrate that the lack of influenza A and B virus reassortants can be attributed at least in part to incompatibilities in the virus-specific packaging signals required for effective segment incorporation into nascent virions. IMPORTANCE Reassortment of influenza A or B viruses provides an evolutionary strategy leading to unique genotypes, which can spawn influenza A viruses with pandemic potential. However, the mechanism preventing intertypic reassortment or gene exchange between influenza A and B viruses is not well understood. Nucleotides comprising the coding termini of each influenza A virus gene segment are required for specific segment incorporation during budding. Whether influenza B virus shares a similar selective packaging strategy or if packaging signals prevent intertypic reassortment remains unknown. Here, we provide evidence suggesting a similar mechanism of influenza B virus genome packaging. Furthermore, by appending influenza A virus packaging signals onto influenza B virus segments, we rescued recombinant influenza A/B viruses that could reassort in vitro with another influenza A virus. These findings suggest that the divergent evolution of packaging signals aids with the speciation of influenza A and B viruses and is in part responsible for the lack of intertypic viral reassortment. PMID:25008914

  15. Consistency of VDJ Rearrangement and Substitution Parameters Enables Accurate B Cell Receptor Sequence Annotation.

    PubMed

    Ralph, Duncan K; Matsen, Frederick A

    2016-01-01

    VDJ rearrangement and somatic hypermutation work together to produce antibody-coding B cell receptor (BCR) sequences for a remarkable diversity of antigens. It is now possible to sequence these BCRs in high throughput; analysis of these sequences is bringing new insight into how antibodies develop, in particular for broadly-neutralizing antibodies against HIV and influenza. A fundamental step in such sequence analysis is to annotate each base as coming from a specific one of the V, D, or J genes, or from an N-addition (a.k.a. non-templated insertion). Previous work has used simple parametric distributions to model transitions from state to state in a hidden Markov model (HMM) of VDJ recombination, and assumed that mutations occur via the same process across sites. However, codon frame and other effects have been observed to violate these parametric assumptions for such coding sequences, suggesting that a non-parametric approach to modeling the recombination process could be useful. In our paper, we find that indeed large modern data sets suggest a model using parameter-rich per-allele categorical distributions for HMM transition probabilities and per-allele-per-position mutation probabilities, and that using such a model for inference leads to significantly improved results. We present an accurate and efficient BCR sequence annotation software package using a novel HMM "factorization" strategy. This package, called partis (https://github.com/psathyrella/partis/), is built on a new general-purpose HMM compiler that can perform efficient inference given a simple text description of an HMM.

  16. Design, Fabrication, and Packaging of Mach-Zehnder Interferometers for Biological Sensing Applications

    NASA Astrophysics Data System (ADS)

    Novak, Joseph

    Optical biological sensors are widely used in the fields of medical testing, water treatment and safety, gene identification, and many others due to advances in nanofabrication technology. This work focuses on the design of fiber-coupled Mach-Zehnder Interferometer (MZI) based biosensors fabricated on silicon-on-insulator (SOI) wafer. Silicon waveguide sensors are designed with multimode and single-mode dimensions. Input coupling efficiency is investigated by design of various taper structures. Integration processing and packaging is performed for fiber attachment and enhancement of input coupling efficiency. Optical guided-wave sensors rely on single-mode operation to extract an induced phase-shift from the output signal. A silicon waveguide MZI sensor designed and fabricated for both multimode and single-mode dimensions. Sensitivity of the sensors is analyzed for waveguide dimensions and materials. An s-bend structure is designed for the multimode waveguide to eliminate higher-order mode power as an alternative to single-mode confinement. Single-mode confinement is experimentally demonstrated through near field imaging of waveguide output. Y-junctions are designed for 3dB power splitting to the MZI arms and for power recombination after sensing to utilize the interferometric function of the MZI. Ultra-short 10microm taper structures with curved geometries are designed to improve insertion loss from fiber-to-chip without significantly increasing device area and show potential for applications requiring misalignment tolerance. An novel v-groove process is developed for self-aligned integration of fiber grooves for attachment to sensor chips. Thermal oxidation at temperatures from 1050-1150°C during groove processing creates an SiO2 layer on the waveguide end facet to protect the waveguide facet during integration etch processing without additional e-beam lithography processing. Experimental results show improvement of insertion loss compared to dicing preparation and Focused Ion Beam methods using the thermal oxidation process.

  17. Mitochondrial DNA transfer to the nucleus generates extensive insertion site variation in maize.

    PubMed

    Lough, Ashley N; Roark, Leah M; Kato, Akio; Ream, Thomas S; Lamb, Jonathan C; Birchler, James A; Newton, Kathleen J

    2008-01-01

    Mitochondrial DNA (mtDNA) insertions into nuclear chromosomes have been documented in a number of eukaryotes. We used fluorescence in situ hybridization (FISH) to examine the variation of mtDNA insertions in maize. Twenty overlapping cosmids, representing the 570-kb maize mitochondrial genome, were individually labeled and hybridized to root tip metaphase chromosomes from the B73 inbred line. A minimum of 15 mtDNA insertion sites on nine chromosomes were detectable using this method. One site near the centromere on chromosome arm 9L was identified by a majority of the cosmids. To examine variation in nuclear mitochondrial DNA sequences (NUMTs), a mixture of labeled cosmids was applied to chromosome spreads of ten diverse inbred lines: A188, A632, B37, B73, BMS, KYS, Mo17, Oh43, W22, and W23. The number of detectable NUMTs varied dramatically among the lines. None of the tested inbred lines other than B73 showed the strong hybridization signal on 9L, suggesting that there is a recent mtDNA insertion at this site in B73. Different sources of B73 and W23 were examined for NUMT variation within inbred lines. Differences were detectable, suggesting either that mtDNA is being incorporated or lost from the maize nuclear genome continuously. The results indicate that mtDNA insertions represent a major source of nuclear chromosomal variation.

  18. Alternative method for predicting optimal insertion depth of the laryngeal tube in children.

    PubMed

    Kim, J T; Jeon, S Y; Kim, C S; Kim, S D; Kim, H S

    2007-11-01

    Little information is available about the accuracy of the teeth mark on the laryngeal tube (LT) as a guide to correct placement in children. The aim of this crossover study was to evaluate three methods for optimal insertion depth of the size (#) 2 tube in children weighing 12-25 kg. In 24 children, the LT #2 was consecutively inserted by three different methods: (A) until the thick teeth mark on the tube was aligned with the upper incisors, (B) until resistance was felt, and (C) by inserting to a depth, previously measured, of the curved distance between the cricoid cartilage and the upper incisor. In each case, the depth of insertion, the degree of effective ventilation, the presence of leakage, and the fibreoptic view were assessed. Insertion based on the teeth mark led to a shorter insertion depth and a greater incidence of inadequate ventilation compared with the other two methods. There was no difference in the adequacy of ventilation between methods B and C. The vocal cords were more easily identified with methods B (62.5%) and C (75%) than with method A (12.5%). Insertion of the LT #2 aligned with the teeth mark can result in a shallow insertion depth and inadequate ventilation. The measured distance from the cricoid cartilage to the upper incisor offers alternative guidance for correct LT insertion.

  19. Virus-Like Particles Derived from HIV-1 for Delivery of Nuclear Proteins: Improvement of Production and Activity by Protein Engineering.

    PubMed

    Robert, Marc-André; Lytvyn, Viktoria; Deforet, Francis; Gilbert, Rénald; Gaillet, Bruno

    2017-01-01

    Virus-like particles (VLPs) derived from retroviruses and lentiviruses can be used to deliver recombinant proteins without the fear of causing insertional mutagenesis to the host cell genome. In this study we evaluate the potential of an inducible lentiviral vector packaging cell line for VLP production. The Gag gene from HIV-1 was fused to a gene encoding a selected protein and it was transfected into the packaging cells. Three proteins served as model: the green fluorescent protein and two transcription factors-the cumate transactivator (cTA) of the inducible CR5 promoter and the human Krüppel-like factor 4 (KLF4). The sizes of the VLPs were 120-150 nm in diameter and they were resistant to freeze/thaw cycles. Protein delivery by the VLPs reached up to 100% efficacy in human cells and was well tolerated. Gag-cTA triggered up to 1100-fold gene activation of the reporter gene in comparison to the negative control. Protein engineering was required to detect Gag-KLF4 activity. Thus, insertion of the VP16 transactivation domain increased the activity of the VLPs by eightfold. An additional 2.4-fold enhancement was obtained by inserting nuclear export signal. In conclusion, our platform produced VLPs capable of efficient protein transfer, and it was shown that protein engineering can be used to improve the activity of the delivered proteins as well as VLP production.

  20. Prospective clinical evaluation of the Polyperf® Safe, a safety Huber needle, in cancer patients.

    PubMed

    Goossens, Godelieve A; Moons, Philip; Jérôme, Martine; Stas, Marguerite

    2011-01-01

    Evaluation of the Polyperf® Safe (PPS) needle on safety and user-friendliness, as experienced by first-time and non-first-time users of the device. A prospective, descriptive study was carried out at the University Hospitals Leuven, Belgium. Five hundred PPS needles were individually evaluated in cancer patients. Different aspects of the PPS were assessed: packaging, needle insertion, and needle removal. Nurses were asked whether they had previously inserted or removed this type of needle. We compared the PPS needle with the standard Gripper® needle in terms of safety, ease of use, and ease of training. Three hundred sixty-six evaluation forms were available for analysis (73.2%). Packaging and access evaluations were scored positively, except for two aspects: (1) needle stability, and (2) ease of dressing. Ease of removal was scored unsatisfactory in up to 22.4% of the registrations. Pain at insertion was reported in about 20% registrations, and blood contact was reported by 2.5% of non-first-time users. Safety was scored as good, although ease of use and ease in training scored 25.4% and 43.8%, respectively, lower than the Gripper®. In general, nurses evaluated the PPS positively, with the exception of needle stability, ease of dressing, and ease of removal. No needlestick accidents were recorded. Aspects of ease of use and ease of training for PPS needles scored less than those for the Gripper® needles in up to one-third of the registrations.

  1. Linked Tumor-Selective Virus Replication and Transgene Expression from E3-Containing Oncolytic Adenoviruses†

    PubMed Central

    Zhu, Mingzhu; Bristol, J. Andrew; Xie, Yuefeng; Mina, Mervat; Ji, Hong; Forry-Schaudies, Suzanne; Ennist, David L.

    2005-01-01

    Historically, the adenoviral E3 region was found to be nonessential for viral replication in vitro. In addition, adenoviruses whose genome was more than approximately 105% the size of the native genome were inefficiently packaged. These profound observations were used experimentally to insert transgenes into the adenoviral backbone. More recently, however, the reintroduction of the E3 region into oncolytic adenoviruses has been found to positively influence antitumor efficacy in preclinical models and clinical trials. In the studies reported here, the granulocyte-macrophage colony-stimulating factor (GM-CSF) cDNA sequence has been substituted for the E3-gp19 gene in oncolytic adenoviruses that otherwise retained the E3 region. Five viruses that differed slightly in the method of transgene insertion were generated and compared to Ar6pAE2fGmF (E2F/GM/ΔE3), a previously described E3-deleted oncolytic adenovirus encoding GM-CSF. In all of the viruses, the human E2F-1 promoter regulated E1A expression and GM-CSF expression was under the control of the adenoviral E3 promoter and the packaging signal was relocated immediately upstream from the right terminal repeat. The E3-gp19-deleted viruses had similar cytolytic properties, as measured in vitro by cytotoxicity assays, but differed markedly in their capacity to express and secrete GM-CSF. Ar15pAE2fGmF (E2F/GM/E3b), the virus that produced the highest levels of GM-CSF and retained the native GM-CSF leader sequence, was selected for further analysis. The E2F/GM/E3b and E2F/GM/ΔE3 viruses exhibited similar cytotoxic activity and GM-CSF production in several tumor cell lines in vitro. However, when compared in vivo in nude mouse xenograft tumor models, E2F/GM/E3b spread through tumors to a greater extent, resulted in higher peak GM-CSF and total exposure levels in both tumor and serum, and was more efficacious than the E3-deleted virus. Using the matched WI-38 (parental) and WI-38-VA13 (simian virus 40 large T antigen transformed) cell pair, GM-CSF was shown to be selectively produced in cells expressing high levels of E2F, indicating that the tumor-selective E2F promoter controlled E1A and GM-CSF expression. PMID:15827160

  2. 49 CFR 172.514 - Bulk packagings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... § 172.302(b)(2) in place of the UN number on an orange panel, placard or white square-on-point; and (5..., shall affix the placards specified for the material in §§ 172.504 and 172.505. (b) Each bulk packaging... § 173.29(b)(1) of this subchapter. (c) Exceptions. The following packagings may be placarded on only two...

  3. 49 CFR 172.514 - Bulk packagings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... § 172.302(b)(2) in place of the UN number on an orange panel, placard or white square-on-point; and (5..., shall affix the placards specified for the material in §§ 172.504 and 172.505. (b) Each bulk packaging... § 173.29(b)(1) of this subchapter. (c) Exceptions. The following packagings may be placarded on only two...

  4. 78 FR 63226 - GlaxoSmithKline LLC; Withdrawal of Approval of the Indication for Treatment of Patients With...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-23

    ... have not received prior rituximab, for BEXXAR (tositumomab and iodine I 131 tositumomab) Injection held... withdraw the rituximab-na[iuml]ve indication for BEXXAR (tositumomab and iodine I 131 tositumomab... indication for BEXXAR (tositumomab and iodine I 131 tositumomab) Injection from the package insert. In the...

  5. 78 FR 26090 - Content Specifications and Shielding Evaluations for Type B Transportation Packages

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-03

    ...The U.S. Nuclear Regulatory Commission (NRC) is issuing Regulatory Issue Summary (RIS) 2013-04, ``Content Specifications and Shielding Evaluations for Type B Transportation Packages.'' This RIS clarifies the NRC's use of staff guidance in NUREG-1609, ``Standard Review Plan for Transport Packages for Radioactive Material,'' for the review of content specifications and shielding evaluations included in the Certificates of Compliance (CoC) and safety analysis reports (SARs) for Type B transportation packages. The RIS does not impose any additional regulatory requirements on NRC licensees.

  6. GSFC Cutting Edge Avionics Technologies for Spacecraft

    NASA Technical Reports Server (NTRS)

    Luers, Philip J.; Culver, Harry L.; Plante, Jeannette

    1998-01-01

    With the launch of NASA's first fiber optic bus on SAMPEX in 1992, GSFC has ushered in an era of new technology development and insertion into flight programs. Predating such programs the Lewis and Clark missions and the New Millenium Program, GSFC has spearheaded the drive to use cutting edge technologies on spacecraft for three reasons: to enable next generation Space and Earth Science, to shorten spacecraft development schedules, and to reduce the cost of NASA missions. The technologies developed have addressed three focus areas: standard interface components, high performance processing, and high-density packaging techniques enabling lower cost systems. To realize the benefits of standard interface components GSFC has developed and utilized radiation hardened/tolerant devices such as PCI target ASICs, Parallel Fiber Optic Data Bus terminals, MIL-STD-1773 and AS1773 transceivers, and Essential Services Node. High performance processing has been the focus of the Mongoose I and Mongoose V rad-hard 32-bit processor programs as well as the SMEX-Lite Computation Hub. High-density packaging techniques have resulted in 3-D stack DRAM packages and Chip-On-Board processes. Lower cost systems have been demonstrated by judiciously using all of our technology developments to enable "plug and play" scalable architectures. The paper will present a survey of development and insertion experiences for the above technologies, as well as future plans to enable more "better, faster, cheaper" spacecraft. Details of ongoing GSFC programs such as Ultra-Low Power electronics, Rad-Hard FPGAs, PCI master ASICs, and Next Generation Mongoose processors.

  7. Minor displacements in the insertion site provoke major differences in the induction of antibody responses by chimeric parvovirus-like particles.

    PubMed

    Rueda, P; Hurtado, A; del Barrio, M; Martínez-Torrecuadrada, J L; Kamstrup, S; Leclerc, C; Casal, J I

    1999-10-10

    An antigen-delivery system based on hybrid virus-like particles (VLPs) formed by the self-assembly of the capsid VP2 protein of canine parvovirus (CPV) and expressing foreign peptides was investigated. In this report, we have studied the effects of inserting the poliovirus C3:B epitope in the four loops and the C terminus of the CPV VP2 on the particle structure and immunogenicity. Epitope insertions in the four loops allowed the recovery of capsids in all of the mutants. However, only insertions of the C3:B epitope in VP2 residue 225 of the loop 2 were able to elicit a significant anti-peptide antibody response, but not poliovirus-neutralizing antibodies, probably because residue 225 is located in an small depression of the surface. To fine modulate the insertion site in loop 2, a cassette-mutagenesis was carried out to insert the epitope in adjacent positions 226, 227, and 228. The epitope C3:B inserted into these positions was well recognized by the specific monoclonal antibody C3 by immunoelectron microscopy. BALB/c mice immunized with these chimeric C3:B CPV:VLPs were able to elicit an strong neutralizing antibody response (>3 log(10) units) against poliovirus type 1 (Mahoney strain). Therefore, minor displacements in the insertion place cause dramatic changes in the accessibility of the epitope and the induction of antibody responses. Copyright 1999 Academic Press.

  8. MEMS Direct Chip Attach Packaging Methodologies and Apparatuses for Harsh Environments

    NASA Technical Reports Server (NTRS)

    Okojie, Robert S. (Inventor)

    2009-01-01

    Methods of bulk manufacturing high temperature sensor subassembly packages are disclosed and claimed. Sensors are sandwiched between a top cover and a bottom cover so as to enable the peripheries of the top covers, sensors and bottom covers to be sealed and bound securely together are disclosed and claimed. Sensors are placed on the bottom covers leaving the periphery of the bottom cover exposed. Likewise, top covers are placed on the sensors leaving the periphery of the sensor exposed. Individual sensor sub-assemblies are inserted into final packaging elements which are also disclosed and claimed. Methods of directly attaching wires or pins to contact pads on the sensors are disclosed and claimed. Sensors, such as pressure sensors and accelerometers, and headers made out of silicon carbide and aluminum nitride are disclosed and claimed. Reference cavities are formed in some embodiments disclosed and claimed herein where top covers are not employed.

  9. MEMS Direct Chip Attach Packaging Methodologies and Apparatuses for Harsh Environments

    NASA Technical Reports Server (NTRS)

    Okojie, Robert S. (Inventor)

    2005-01-01

    Methods of bulk manufacturing high temperature sensor sub-assembly packages are disclosed and claimed. Sensors are sandwiched between a top cover and a bottom cover so as to enable the peripheries of the top covers, sensors and bottom covers to be sealed and bound securely together are disclosed and claimed. Sensors are placed on the bottom covers leaving the periphery of the bottom cover exposed. Likewise, top covers are placed on the sensors leaving the periphery of the sensor exposed. Individual sensor sub- assemblies are inserted into final packaging elements which are also disclosed and claimed. Methods of directly attach- ing wires or pins to contact pads on the sensors are disclosed and claimed. Sensors, such as pressure sensors and accelerometers, and headers made out of silicon carbide and aluminum nitride are disclosed and claimed. Reference cavities are formed in some embodiments disclosed and claimed herein where top covers are not employed.

  10. MR Performance Comparison of a PET/MR System Before and After SiPM-Based Time-of-Flight PET Detector Insertion

    NASA Astrophysics Data System (ADS)

    Khalighi, Mohammad Mehdi; Delso, Gaspar; Maramraju, Sri Harsha; Deller, Timothy W.; Levin, Craig S.; Glover, Gary H.

    2016-10-01

    A silicon photomultiplier (SiPM)-based time-of-flight capable PET detector has been integrated with a 70 cm wide-bore 3T MR scanner for simultaneous whole-body imaging (MR750w, GE Healthcare, Waukesha, WI). After insertion of the PET detector, the final PET/MR bore is 60 cm wide (SIGNA PET/MR, GE Healthcare, Waukesha, WI). The MR performance was compared before and after the PET ring insertion. B0 homogeneity, B1+ uniformity of the body coil along with peak B1+, coherent noise, and FBIRN (Function Biomedical Informatics Research Network) tests are used to compare the MR performance. It is shown that B0 homogeneity and coherent noise have not changed according to the system specifications. Peak B1+ is increased by 33% and B1+ inhomogeneity is increased by 4% after PET ring insertion due to a smaller diameter body coil design. The FBIRN test shows similar temporal stability before and after PET ring insertion. Due to a smaller body coil on the PET/MR system, the signal fluctuation to noise ratio (SFNR) and SNR for body receive coil, are improved by 40% and 160% for Echo Planar Imaging (EPI) and spiral sequences respectively. Comparison using RF- and gradient-intensive clinical sequences shows inserting the PET detectors into the wide-bore MRI has not compromised the MR image quality according to these tests.

  11. Influence of inserted Mo layer on the thermal stability of perpendicularly magnetized Ta/Mo/Co{sub 20}Fe{sub 60}B{sub 20}/MgO/Ta films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Minghua, E-mail: mhli@ustb.edu.cn; Department of Electrical Engineering, University of California, Los Angeles, California 90095; Lu, Jinhui

    2016-04-15

    We studied the thermal stability of perpendicular magnetic anisotropy (PMA) in Ta/Mo/CoFeB/MgO/Ta films with and without inserted Mo layers. In the absence of a Mo layer, the films show PMA at annealing temperatures below 300 °C. On the other hand, the insertion of a Mo layer preserves PMA at annealing temperatures of up to 500 °C; however, a higher annealing temperature leads to the collapse of PMA. X-ray photoelectron spectroscopy (XPS) and high-resolution transmission electron microscopy (HRTEM) were used to study the microstructure of the films to understand the deterioration of PMA. The XPS results show that the segregation ofmore » Ta is partly suppressed by inserting a Mo layer. Once inserted, Mo does not remain at the interface of Ta and CoFeB but migrates to the surface of the films. The HRTEM results show that the crystallization of the MgO (001) texture is improved owing to the higher annealing temperature of the Mo inserted sample. A smooth and clear CoFeB/MgO interface is evident. The inserted Mo layer not only helps to obtain sharper and smoother interfaces but also contributes to the crystallization after the higher annealing temperature of films.« less

  12. Effect of Polishing on the Friction Behaviors and Cutting Performance of Boron-Doped Diamond Films on WC-Co Inserts

    NASA Astrophysics Data System (ADS)

    Wang, Liang; Shen, Bin; Sun, Fanghong; Zhang, Zhiming

    2014-04-01

    Boron doped (B-doped) diamond films are deposited onto WC-Co inserts by HFCVD with the mixture of acetone, trimethyl borate (C3H9BO3) and H2. The as-deposited B-doped diamond films are characterized with scanning electron microscope (SEM), X-ray diffraction (XRD) spectroscopy, Raman spectroscopy, 3D surface topography based on white-light interferometry and Rockwell hardness tester. The effects of mechanical polishing on the friction behavior and cutting performance of B-doped diamond are evaluated by ball-on-plate type reciprocating tribometer and turning of aluminum alloy 7075 materials, respectively. For comparison, the same tests are also conducted for the bare WC-Co inserts with smooth surface. Friction tests suggest that the unpolished and polished B-doped diamond films possess relatively low fluctuation of friction coefficient than as-received bare WC-Co samples. The average stable friction coefficient for B-doped diamond films decreases apparently after mechanical polishing. The values for WC-Co sample, unpolished and polished B-doped diamond films are approximately 0.38, 0.25 and 0.11, respectively. The cutting results demonstrate that the low friction coefficient and high adhesive strength of B-doped diamond films play an essential role in the cutting performance enhancement of the WC-Co inserts. However, the mechanical polishing process may lower the adhesive strength of B-doped diamond films. Consequently, the polished B-doped diamond coated inserts show premature wear in the machining of adhesive aluminum alloy materials.

  13. High-energy metal air batteries

    DOEpatents

    Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

    2014-07-01

    Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

  14. High-energy metal air batteries

    DOEpatents

    Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

    2013-07-09

    Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

  15. Validation of a commercial TPS based on the VMC(++) Monte Carlo code for electron beams: commissioning and dosimetric comparison with EGSnrc in homogeneous and heterogeneous phantoms.

    PubMed

    Ferretti, A; Martignano, A; Simonato, F; Paiusco, M

    2014-02-01

    The aim of the present work was the validation of the VMC(++) Monte Carlo (MC) engine implemented in the Oncentra Masterplan (OMTPS) and used to calculate the dose distribution produced by the electron beams (energy 5-12 MeV) generated by the linear accelerator (linac) Primus (Siemens), shaped by a digital variable applicator (DEVA). The BEAMnrc/DOSXYZnrc (EGSnrc package) MC model of the linac head was used as a benchmark. Commissioning results for both MC codes were evaluated by means of 1D Gamma Analysis (2%, 2 mm), calculated with a home-made Matlab (The MathWorks) program, comparing the calculations with the measured profiles. The results of the commissioning of OMTPS were good [average gamma index (γ) > 97%]; some mismatches were found with large beams (size ≥ 15 cm). The optimization of the BEAMnrc model required to increase the beam exit window to match the calculated and measured profiles (final average γ > 98%). Then OMTPS dose distribution maps were compared with DOSXYZnrc with a 2D Gamma Analysis (3%, 3 mm), in 3 virtual water phantoms: (a) with an air step, (b) with an air insert, and (c) with a bone insert. The OMTPD and EGSnrc dose distributions with the air-water step phantom were in very high agreement (γ ∼ 99%), while for heterogeneous phantoms there were differences of about 9% in the air insert and of about 10-15% in the bone region. This is due to the Masterplan implementation of VMC(++) which reports the dose as "dose to water", instead of "dose to medium". Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  16. [Isolation and function of genes regulating aphB expression in Vibrio cholerae].

    PubMed

    Chen, Haili; Zhu, Zhaoqin; Zhong, Zengtao; Zhu, Jun; Kan, Biao

    2012-02-04

    We identified genes that regulate the expression of aphB, the gene encoding a key virulence regulator in Vibrio cholerae O1 E1 Tor C6706(-). We constructed a transposon library in V. cholerae C6706 strain containing a P(aphB)-luxCDABE and P(aphB)-lacZ transcriptional reporter plasmids. Using a chemiluminescence imager system, we rapidly detected aphB promoter expression level at a large scale. We then sequenced the transposon insertion sites by arbitrary PCR and sequencing analysis. We obtained two candidate mutants T1 and T2 which displayed reduced aphB expression from approximately 40,000 transposon insertion mutants. Sequencing analysis shows that Tn inserted in vc1585 reading frame in the T1 mutant and Tn inserted in the end of coding sequence of vc1602 in the T2 mutant. By using a genetic screen, we identified two potential genes that may involve in regulation of the expression of the key virulence regulator AphB. This study sheds light on our further investigation to fully understand V. cholerae virulence gene regulatory cascades.

  17. 49 CFR 173.24a - Additional general requirements for non-bulk packagings and packages.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... subchapter. (b) Non-bulk packaging filling limits. (1) A single or composite non-bulk packaging may be filled... gross mass marked on the packaging. (3) A single or composite non-bulk packaging which is tested and... marked on the packaging, or 1.2 if not marked. In addition: (i) A single or composite non-bulk packaging...

  18. 49 CFR 173.24a - Additional general requirements for non-bulk packagings and packages.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... subchapter. (b) Non-bulk packaging filling limits. (1) A single or composite non-bulk packaging may be filled... gross mass marked on the packaging. (3) A single or composite non-bulk packaging which is tested and... marked on the packaging, or 1.2 if not marked. In addition: (i) A single or composite non-bulk packaging...

  19. 49 CFR 173.24a - Additional general requirements for non-bulk packagings and packages.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... subchapter. (b) Non-bulk packaging filling limits. (1) A single or composite non-bulk packaging may be filled... gross mass marked on the packaging. (3) A single or composite non-bulk packaging which is tested and... marked on the packaging, or 1.2 if not marked. In addition: (i) A single or composite non-bulk packaging...

  20. MEMS Reliability Assurance Guidelines for Space Applications

    NASA Technical Reports Server (NTRS)

    Stark, Brian (Editor)

    1999-01-01

    This guide is a reference for understanding the various aspects of microelectromechanical systems, or MEMS, with an emphasis on device reliability. Material properties, failure mechanisms, processing techniques, device structures, and packaging techniques common to MEMS are addressed in detail. Design and qualification methodologies provide the reader with the means to develop suitable qualification plans for the insertion of MEMS into the space environment.

  1. Rationale for patient package inserts.

    PubMed

    Morris, L A

    1978-02-01

    The need for patient package inserts (PPIs) is discussed in terms of the "consumers' right-to-know" and "patient health education" themes, as well as the premise that verbal means of communication are often inadequate. Some of the reasons for the frequent failure of verbal messages are reviewed by detailing the five stages through which any communication must be processed in order to be effective. Verbal information may be inadequate because: (1) patients are not exposed to necessary material, (2) they may not pay attention to the information, (3) they may not understand it, (4) the information may not be accepted as valid, and (5) patients may not remember the material. Written communication which must be processed through the same five stages also may be frequently inadequate. Therefore, PPIs must be viewed as reinforcing and augmenting verbal consultation, and both written and verbal forms are necessary. Consumer surveys and demonstration projects have shown that written communications are a desired and effective means for conveying additional prescription drug information to patients. The wide implementation of PPIs is apt to cause many problems for the pharmacists; however, it may also serve as a means to enhance the pharmacist's clinical role.

  2. Graphical content of medicinal package inserts: an exploratory study to evaluate potential legibility issues.

    PubMed

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2016-06-01

    The graphical content of the Medicines Package Inserts (MPIs), such as illustrations and typographic features should be legible and appropriate, as required by international pharmaceutical regulations. To study: (1) the frequency and type of MPIs' key graphic elements, (2) their compliance with regulations and (3) how educated people understand them. Descriptive study: characterisation of the graphical content of 651 MPIs. Usability study: illustrations and tables (purposively selected) were evaluated with questionnaires in three groups of humanities undergraduates (illustrations only, illustrations plus text and text only). Descriptive study: illustrations and tables were respectively identified in 6.3% and 11.8% of the MPIs. The illustrations were mainly related to how to take/use the medicine. Non-recommended graphical representations were found (e.g. italic or underline). Usability test: legibility issues were identified, especially for the group of isolated illustrations. The scarce use of illustrations and tables possibly affected the legibility of the MPIs. Compulsory legibility tests are needed to guarantee the MPIs' proper use, thus contributing to a safe use of medicines. Overall, this study highlighted the need to carefully revise/assess the MPIs' design and probably increase health information experts' awareness on this issue. © 2015 Health Libraries Group.

  3. The P gene of bovine parainfluenza virus 3 expresses all three reading frames from a single mRNA editing site.

    PubMed Central

    Pelet, T; Curran, J; Kolakofsky, D

    1991-01-01

    The P gene of bovine parainfluenza virus 3 (bPIV3) contains two downstream overlapping ORFs, called V and D. By comparison with the mRNA editing sites of other paramyxoviruses, two editing sites were predicted for bPIV3; site a to express the D protein, and site b to express the V protein. Examination of the bPIV3 mRNAs, however, indicates that site b is non-functional whereas site a operates frequently. Insertions at site a give rise to both V and D protein mRNAs, because a very broad distribution of Gs is added when insertions occur. This broad distribution is very different from the editing sites of Sendai virus or SV5, where predominantly one form of edited mRNA containing either a one or two G insertion respectively is created, to access the single overlapping ORF of these viruses. A model is proposed to explain how paramyxoviruses control the range of G insertions on that fraction of the mRNAs where insertions occur. The bPIV3 P gene is unique as far as we know, in that a sizeable portion of the gene expresses all 3 reading frames as protein. bPIV3 apparently does this from a single editing site by removing the constraints which control the number of slippage rounds which take place. Images PMID:1846805

  4. Nonradiative inter- and intramolecular energy transfer from the aromatic donor anisole to a synthesized photoswitchable acceptor system.

    PubMed

    Bardhan, Munmun; Bhattacharya, Sudeshna; Misra, Tapas; Mukhopadhyay, Rupa; De, Asish; Chowdhury, Joydeep; Ganguly, Tapan

    2010-02-01

    We report steady state and time resolved fluorescence measurements on acetonitrile (ACN) solutions of the model compounds, energy donor anisole (A) and a photoswitchable acceptor N,N'-1,2-phenylene di-p-tosylamide (B) and the multichromophore (M) where A and B are connected by a spacer containing both rigid triple (acetylenic) and flexible methylene bonds. Both steady state and time correlated single photon counting measurements demonstrate that though intermolecular energy transfer, of Forster type, between the donor and acceptor moieties occurs with rate 10(8)s(-1) but when these two reacting components are linked by a spacer (multichromophore, M) the observed transfer rate ( approximately 10(11)s(-1)) enhances. This seemingly indicates that the imposition of the spacer by inserting a triple bond may facilitate in the propagation of electronic excitation energy through bond. The time resolved fluorescence measurements along with the theoretical predictions using Configuration interaction singles (CIS) method by using 6-31G (d,p) basis set, implemented in the Gaussian package indicate the formations of the two excited conformers of B. The experimental findings made from the steady state and time resolved fluorescence measurements demonstrate that, though two different isomeric species of the acceptor B are formed in the excited singlet states, the prevailing singlet-singlet nonradiative energy transfer route was found from the donor A to the relatively longer-lived isomeric species of B. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  5. Design of Multi-core Fiber Patch Panel for Space Division Multiplexing Implementations

    NASA Astrophysics Data System (ADS)

    González, Luz E.; Morales, Alvaro; Rommel, Simon; Jørgensen, Bo F.; Porras-Montenegro, N.; Tafur Monroy, Idelfonso

    2018-03-01

    A multi-core fiber (MCF) patch panel was designed, allowing easy coupling of individual signals to and from a 7-core MCF. The device was characterized, measuring insertion loss and cross talk, finding highest insertion loss and lowest crosstalk at 1300 nm with values of 9.7 dB and -36.5 dB respectively, while at 1600 nm insertion loss drops to 4.8 dB and crosstalk increases to -24.1 dB. Two MCF splices between the fan-in module, the MCF, and the fan-out module are included in the characterization, and splicing parameters are discussed.

  6. Response Changes During Insertion of a Cochlear Implant Using Extracochlear Electrocochleography.

    PubMed

    Giardina, Christopher K; Khan, Tatyana E; Pulver, Stephen H; Adunka, Oliver F; Buchman, Craig A; Brown, Kevin D; Pillsbury, Harold C; Fitzpatrick, Douglas C

    2018-03-16

    Electrocochleography is increasingly being utilized as an intraoperative monitor of cochlear function during cochlear implantation (CI). Intracochlear recordings from the advancing electrode can be obtained through the device by on-board capabilities. However, such recordings may not be ideal as a monitor because the recording electrode moves in relation to the neural and hair cell generators producing the responses. The purposes of this study were to compare two extracochlear recording locations in terms of signal strength and feasibility as intraoperative monitoring sites and to characterize changes in cochlear physiology during CI insertion. In 83 human subjects, responses to 90 dB nHL tone bursts were recorded both at the round window (RW) and then at an extracochlear position-either adjacent to the stapes or on the promontory just superior to the RW. Recording from the fixed, extracochlear position continued during insertion of the CI in 63 cases. Before CI insertion, responses to low-frequency tones at the RW were roughly 6 dB larger than when recording at either extracochlear site, but the two extracochlear sites did not differ from one another. During CI insertion, response losses from the promontory or adjacent to the stapes stayed within 5 dB in ≈61% (38/63) of cases, presumably indicating atraumatic insertions. Among responses which dropped more than 5 dB at any time during CI insertion, 12 subjects showed no response recovery, while in 13, the drop was followed by partial or complete response recovery by the end of CI insertion. In cases with recovery, the drop in response occurred relatively early (<15 mm insertion) compared to those where there was no recovery. Changes in response phase during the insertion occurred in some cases; these may indicate a change in the distributions of generators contributing to the response. Monitoring the electrocochleography during CI insertion from an extracochlear site reveals insertions that are potentially atraumatic show interaction with cochlear structures followed by response recovery or show interactions such that response losses persist to the end of recording.

  7. Primary structure and mapping of the hupA gene of Salmonella typhimurium.

    PubMed Central

    Higgins, N P; Hillyard, D

    1988-01-01

    In bacteria, the complex nucleoid structure is folded and maintained by negative superhelical tension and a set of type II DNA-binding proteins, also called histonelike proteins. The most abundant type II DNA-binding protein is HU. Southern blot analysis showed that Salmonella typhimurium contained two HU genes that corresponded to Escherichia coli genes hupA (encoding HU-2 protein) and hupB (encoding HU-1). Salmonella hupA was cloned, and the nucleotide sequence of the gene was determined. Comparison of hupA of E. coli and S. typhimurium revealed that the HU-2 proteins were identical and that there was high conservation of nucleotide sequences outside the coding frames of the genes. A 300-member genomic library of S. typhimurium was constructed by using random transposition of MudP, a specialized chimeric P22-Mu phage that packages chromosomal DNA unidirectionally from its insertion point. Oligonucleotide hybridization against the library identified one MudP insertion that lies within 28 kilobases of hupA; the MudP was 12% linked to purH at 90.5 min on the standard map. Plasmids expressing HU-2 had a surprising phenotype; they caused growth arrest when they were introduced into E. coli strains bearing a himA or hip mutation. These results suggest that IHF and HU have interactive roles in bacteria. Images PMID:3056912

  8. 21 CFR 801.40 - Form of a unique device identifier.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Automatic identification and data capture (AIDC) technology. (b) The UDI must include a device identifier... evident upon visual examination of the label or device package, the label or device package must disclose... label and device packages is deemed to meet all requirements of subpart B of this part. The UPC will...

  9. Examination of Insert Ear Interaural Attenuation (IA)Values in Audiological Evaluations.

    PubMed

    Gumus, Nebi M; Gumus, Merve; Unsal, Selim; Yuksel, Mustafa; Gunduz, Mehmet

    2016-12-01

    The purpose of this study was to evaluate Interaural Attenuation (IA) in frequency base in the insert earphones that are used in audiological assessments. Thirty healthy subjects between 18-65 years of age (14 female and 16 male) participated in our study. Otoscopic examination was performed on all participants. Audiological evaluations were performed using the Interacoustics AC40 clinical audiometer and ER-3A insert earphones. IA value was calculated by subtracting good ear bone conduction hearing thresholds of the worst airway hearing threshold. In our measuring for 0.125-8.0 kHz frequency were performed in our audiometry device separately for each frequency. IA amount in the results we found in 1000 Hz and below frequencies about 75-110 dB range avarage is 89±5dB, in above 1000 Hz frequencies in 50-95 dB range and avarage it is changed to 69±5dB. According to the obtained findings the quantity of melting in the transition between the ears are increasing with the insert earphones. The insert earphone should be beside supraaural earphone that is routinely used in clinics. Difficult masking applications due to the increase in the value of IA can be easily done with insert earphones.

  10. 40 CFR 503.27 - Recordkeeping.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... requirements is met) and the vector attraction reduction requirement in (insert one of the vector attraction... met. (iv) A description of how one of the vector attraction reduction requirements in § 503.33 (b)(1... attraction reduction requirement in (insert one of the requirements in § 503.33(b)(9) through § 503.33(b)(11...

  11. A small and efficient dimerization/packaging signal of rat VL30 RNA and its use in murine leukemia virus-VL30-derived vectors for gene transfer.

    PubMed

    Torrent, C; Gabus, C; Darlix, J L

    1994-02-01

    Retroviral genomes consist of two identical RNA molecules associated at their 5' ends by the dimer linkage structure located in the packaging element (Psi or E) necessary for RNA dimerization in vitro and packaging in vivo. In murine leukemia virus (MLV)-derived vectors designed for gene transfer, the Psi + sequence of 600 nucleotides directs the packaging of recombinant RNAs into MLV virions produced by helper cells. By using in vitro RNA dimerization as a screening system, a sequence of rat VL30 RNA located next to the 5' end of the Harvey mouse sarcoma virus genome and as small as 67 nucleotides was found to form stable dimeric RNA. In addition, a purine-rich sequence located at the 5' end of this VL30 RNA seems to be critical for RNA dimerization. When this VL30 element was extended by 107 nucleotides at its 3' end and inserted into an MLV-derived vector lacking MLV Psi +, it directed the efficient encapsidation of recombinant RNAs into MLV virions. Because this VL30 packaging signal is smaller and more efficient in packaging recombinant RNAs than the MLV Psi + and does not contain gag or glyco-gag coding sequences, its use in MLV-derived vectors should render even more unlikely recombinations which could generate replication-competent viruses. Therefore, utilization of the rat VL30 packaging sequence should improve the biological safety of MLV vectors for human gene transfer.

  12. 26 CFR 1.263(a)-4 - Amounts paid to acquire or create intangibles.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the meaning of this paragraph (b)(3). (v) Creation of package design. Amounts paid to develop a package design are treated as amounts that do not create a separate and distinct intangible asset within the meaning of this paragraph (b)(3). For purposes of this section, the term package design means the...

  13. 26 CFR 1.263(a)-4 - Amounts paid to acquire or create intangibles.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the meaning of this paragraph (b)(3). (v) Creation of package design. Amounts paid to develop a package design are treated as amounts that do not create a separate and distinct intangible asset within the meaning of this paragraph (b)(3). For purposes of this section, the term package design means the...

  14. 26 CFR 1.263(a)-4 - Amounts paid to acquire or create intangibles.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the meaning of this paragraph (b)(3). (v) Creation of package design. Amounts paid to develop a package design are treated as amounts that do not create a separate and distinct intangible asset within the meaning of this paragraph (b)(3). For purposes of this section, the term package design means the...

  15. An EAV-HP Insertion in 5′ Flanking Region of SLCO1B3 Causes Blue Eggshell in the Chicken

    PubMed Central

    Yang, Xiaolin; Li, Guangqi; Zhang, Yuanyuan; Li, Junying; Wang, Xiaotong; Bai, Jirong; Xu, Guiyun; Deng, Xuemei; Yang, Ning; Wu, Changxin

    2013-01-01

    The genetic determination of eggshell coloration has not been determined in birds. Here we report that the blue eggshell is caused by an EAV-HP insertion that promotes the expression of SLCO1B3 gene in the uterus (shell gland) of the oviduct in chicken. In this study, the genetic map location of the blue eggshell gene was refined by linkage analysis in an F2 chicken population, and four candidate genes within the refined interval were subsequently tested for their expression levels in the shell gland of the uterus from blue-shelled and non-blue-shelled hens. SLCO1B3 gene was found to be the only one expressed in the uterus of blue-shelled hens but not in that of non-blue-shelled hens. Results from a pyrosequencing analysis showed that only the allele of SLCO1B3 from blue-shelled chickens was expressed in the uterus of heterozygous hens (O*LC/O*N). SLCO1B3 gene belongs to the organic anion transporting polypeptide (OATP) family; and the OATPs, functioning as membrane transporters, have been reported for the transportation of amphipathic organic compounds, including bile salt in mammals. We subsequently resequenced the whole genomic region of SLCO1B3 and discovered an EAV-HP insertion in the 5′ flanking region of SLCO1B3. The EAV-HP insertion was found closely associated with blue eggshell phenotype following complete Mendelian segregation. In situ hybridization also demonstrated that the blue eggshell is associated with ectopic expression of SLCO1B3 in shell glands of uterus. Our finding strongly suggests that the EAV-HP insertion is the causative mutation for the blue eggshell phenotype. The insertion was also found in another Chinese blue-shelled breed and an American blue-shelled breed. In addition, we found that the insertion site in the blue-shelled chickens from Araucana is different from that in Chinese breeds, which implied independent integration events in the blue-shelled chickens from the two continents, providing a parallel evolutionary example at the molecular level. PMID:23359636

  16. Differences in the Language and Design of Four PPIs for Valium. Technical Assistance Report No. 1.

    ERIC Educational Resources Information Center

    Redish, Janice C.

    As part of the evaluation of four different versions of a patient package insert (PPI) for diazepam (Valium) created by the Food and Drug Administration (FDA), the content, organization, language, and design of the PPIs were compared. One PPI was a short prose piece with clear organization that did not particularly highlight warnings or, indeed,…

  17. 49 CFR 173.4b - De minimis exceptions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... “Scientific research specimens, 49 CFR 173.4b applies.” (6) Documentation. (i) For transportation by highway... “Scientific research specimens, 49 CFR 173.4b applies” and the number of packages indicated. (iii) For... the statement “Scientific research specimens, 49 CFR 173.4b applies” and the number of packages...

  18. 26 CFR 1.381(b)-1 - Operating rules applicable to carryovers in certain corporate acquisitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... for the purpose of winding up its affairs, paying its debts, and distributing any remaining balance of... DISTRIBUTION OR TRANSFER PURSUANT TO § 1.381(b)-1(b)(2),” and must include: [INSERT NAME AND EMPLOYER IDENTIFICATION NUMBER (IF ANY) OF DISTRIBUTOR OR TRANSFEROR CORPORATION] AND [INSERT NAME AND EMPLOYER...

  19. Similarities of Water-soluble Vitamin Components among Non-prescription Pharmaceutical Vitamin Products Generally Available on the Domestic Market.

    PubMed

    Suzuki, Keiichiro; Kojina, Moeko; Aiba, Tetsuya

    2017-01-01

    Similarities among non-prescription pharmaceutical vitamin products generally available in community pharmacies were examined based on their vitamin components, and a chart was constructed to differentiate products to assist in appropriate product choice. In the analysis of the similarities, two hundred and seventy-six data entries on vitamin products were extracted from the database on the package inserts of the pharmaceutical products provided by the Pharmaceuticals and Medical Devices Agency, and they were reviewed for the amounts of vitamins they contained, in which the B vitamins, or vitamin B 1 , B 2 , B 6 , B 12 , and niacin, were considered as well as vitamins C and E. Pantothenic acid and L-Cysteine that are frequently used in combination with those vitamins are also taken into consideration. The data entries were then processed by classical multi-dimensional scaling to evaluate the inter-product similarities. As a result, it was shown that the products categorized as pharmaceutical nutrients and tonics containing vitamins (NTcV) are similar to one another, reflecting the fact that they are less characteristic regarding their vitamin components. As for the products in other categories, they were generally found to be featured for their unique content of vitamin components, and thereby, each category includes products with a wide range of variation. It was also indicated that some products categorized as vitamin B 1 , B 2 , and C products are less distinguishable from those categorized as NTcV. These findings will assist pharmacists to decide on an appropriate product for a customer following consultation.

  20. Influence of the Thermal Conductivity of Thermally Conductive Plastics on the Thermal Distribution of an Light-Emitting Diode Headlight for Vehicles.

    PubMed

    Lee, Dong Kyu; Lee, Jae Min; Cho, Moon Uk; Park, Hyun Jung; Cha, Yu-Jung; Kim, Hyeong Jin; Kwak, Joon Seop

    2018-09-01

    This paper investigates the thermal distribution of an LED headlight for vehicles based on the thermal conductivity of thermally conductive plastics (TCP). In general, heat dissipation structures used for LED headlights are made from metallic materials. However, headlight structures made from TCP have not been investigated. The headlights made from TCP having a various thermal conductivity were fabricated by injection molding with and without a metal plate insert. The temperature characteristics were compared and analyzed using thermal simulations and measurement. The inserted metal in TCP greatly reduced the temperature at solder point, indicating that the fast heat dissipation from the high power LED package to TCP though the inserted metal is essential. The measured temperature at solder points decreased as the thermal conductivity of TCP increased, which is well matched to the simulation results. The measured temperature at the solder point was lower than 150 °C when the thermal conductivity of the TCP was 10 W/mK.

  1. Definition of Small Gram Quantity Contents for Type B Radioactive Material Transportation Packages: Activity-Based Content Limitations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sitaraman, S; Kim, S; Biswas, D

    2010-10-27

    Since the 1960's, the Department of Transportation Specification (DOT Spec) 6M packages have been used extensively for transportation of Type B quantities of radioactive materials between Department of Energy (DOE) facilities, laboratories, and productions sites. However, due to the advancement of packaging technology, the aging of the 6M packages, and variability in the quality of the packages, the DOT implemented a phased elimination of the 6M specification packages (and other DOT Spec packages) in favor of packages certified to meet federal performance requirements. DOT issued the final rule in the Federal Register on October 1, 2004 requiring that use ofmore » the DOT Specification 6M be discontinued as of October 1, 2008. A main driver for the change was the fact that the 6M specification packagings were not supported by a Safety Analysis Report for Packaging (SARP) that was compliant with Title 10 of the Code of Federal Regulations part 71 (10 CFR 71). Therefore, materials that would have historically been shipped in 6M packages are being identified as contents in Type B (and sometimes Type A fissile) package applications and addenda that are to be certified under the requirements of 10 CFR 71. The requirements in 10 CFR 71 include that the Safety Analysis Report for Packaging (SARP) must identify the maximum radioactivity of radioactive constituents and maximum quantities of fissile constituents (10 CFR 71.33(b)(1) and 10 CFR 71.33(b)(2)), and that the application (i.e., SARP submittal or SARP addendum) demonstrates that the external dose rate (due to the maximum radioactivity of radioactive constituents and maximum quantities of fissile constituents) on the surface of the packaging (i.e., package and contents) not exceed 200 mrem/hr (10 CFR 71.35(a), 10 CFR 71.47(a)). It has been proposed that a 'Small Gram Quantity' of radioactive material be defined, such that, when loaded in a transportation package, the dose rates at external points of an unshielded packaging not exceed the regulatory limits prescribed by 10 CFR 71 for non-exclusive shipments. The mass of each radioisotope presented in this paper is limited by the radiation dose rate on the external surface of the package, which per the regulatory limit should not exceed 200 mrem/hr. The results presented are a compendium of allowable masses of a variety of different isotopes (with varying impurity levels of beryllium in some of the actinide isotopes) that, when loaded in an unshielded packaging, do not result in an external dose rate on the surface of the package that exceeds 190 mrem/hr (190 mrem/hr was chosen to provide 5% conservatism relative to the regulatory limit). These mass limits define the term 'Small Gram Quantity' (SGQ) contents in the context of radioactive material transportation packages. The term SGQ is isotope-specific and pertains to contents in radioactive material transportation packages that do not require shielding and still satisfy the external dose rate requirements. Since these calculated mass limits are for contents without shielding, they are conservative for packaging materials that provide some limited shielding or if the contents are placed into a shielded package. The isotopes presented in this paper were chosen as the isotopes that Department of Energy (DOE) sites most likely need to ship. Other more rarely shipped isotopes, along with industrial and medical isotopes, are planned to be included in subsequent extensions of this work.« less

  2. Crush Testing at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feldman, Matthew R

    2011-01-01

    The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type packagemore » designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.« less

  3. An alphavirus temperature-sensitive capsid mutant reveals stages of nucleocapsid assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Yan, E-mail: yzheng15@students.kgi.edu; Kielian, Margaret, E-mail: margaret.kielian@einstein.yu.edu

    2015-10-15

    Alphaviruses have a nucleocapsid core composed of the RNA genome surrounded by an icosahedral lattice of capsid protein. An insertion after position 186 in the capsid protein produced a strongly temperature-sensitive growth phenotype. Even when the structural proteins were synthesized at the permissive temperature (28 °C), subsequent incubation of the cells at the non-permissive temperature (37 °C) dramatically decreased mutant capsid protein stability and particle assembly. Electron microscopy confirmed the presence of cytoplasmic nucleocapsids in mutant-infected cells cultured at the permissive temperature, but these nucleocapsids were not stable to sucrose gradient separation. In contrast, nucleocapsids isolated from mutant virus particlesmore » had similar stability to that of wildtype virus. Our data support a model in which cytoplasmic nucleocapsids go through a maturation step during packaging into virus particles. The insertion site lies in the interface between capsid proteins in the assembled nucleocapsid, suggesting the region where such a stabilizing transition occurs. - Highlights: • We characterize an alphavirus capsid insertion mutation. • These capsid mutants are highly temperature sensitive for growth. • The insertion affects nucleocapsid stability. • Results suggest that the nucleocapsid is stabilized during virus budding.« less

  4. A Novel Retrotransposon Inserted in the Dominant Vrn-B1 Allele Confers Spring Growth Habit in Tetraploid Wheat (Triticum turgidum L.).

    PubMed

    Chu, C-G; Tan, C T; Yu, G-T; Zhong, S; Xu, S S; Yan, L

    2011-12-01

    Vernalization genes determine winter/spring growth habit in temperate cereals and play important roles in plant development and environmental adaptation. In wheat (Triticum L. sp.), it was previously shown that allelic variation in the vernalization gene VRN1 was due to deletions or insertions either in the promoter or in the first intron. Here, we report a novel Vrn-B1 allele that has a retrotransposon in its promoter conferring spring growth habit. The VRN-B1 gene was mapped in a doubled haploid population that segregated for winter-spring growth habit but was derived from two spring tetraploid wheat genotypes, the durum wheat (T. turgidum subsp. durum) variety 'Lebsock' and T. turgidum subsp. carthlicum accession PI 94749. Genetic analysis revealed that Lebsock carried the dominant Vrn-A1 and recessive vrn-B1 alleles, whereas PI 94749 had the recessive vrn-A1 and dominant Vrn-B1 alleles. The Vrn-A1 allele in Lebsock was the same as the Vrn-A1c allele previously reported in hexaploid wheat. No differences existed between the vrn-B1 and Vrn-B1 alleles, except that a 5463-bp insertion was detected in the 5'-UTR region of the Vrn-B1 allele. This insertion was a novel retrotransposon (designated as retrotrans_VRN), which was flanked by a 5-bp target site duplication and contained primer binding site and polypurine tract motifs, a 325-bp long terminal repeat, and an open reading frame encoding 1231 amino acids. The insertion of retrotrans_VRN resulted in expression of Vrn-B1 without vernalization. Retrotrans_VRN is prevalent among T. turgidum subsp. carthlicum accessions, less prevalent among T. turgidum subsp. dicoccum accessions, and rarely found in other tetraploid wheat subspecies.

  5. 49 CFR 178.935 - Standards for wooden Large Packagings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Packagings. (i) Natural wood used in the construction of Large Packagings must be well-seasoned, commercially...) Reconstituted wood used in the construction of Large Packagings must be water resistant reconstituted wood such... Packaging types are designated: (1) 50C natural wood. (2) 50D plywood. (3) 50F reconstituted wood. (b...

  6. A powerful enhancement to the DMAP alter capability

    NASA Technical Reports Server (NTRS)

    Pamidi, P. R.

    1989-01-01

    A powerful enhancement to the DMAP alter capability was developed and is available on all RPK-supported versions of COSMIC/NASTRAN. This enhancement involves the addition of two alter control cards, called INSERT and DELETE, to the Executive Control Deck. These cards allow for DMAP alters to be made by referencing DMAP statements by their module names rather than by their statement numbers in the rigid format DMAP sequence. This allows for increased user convenience and flexibility and makes alters more meaningful to the user. In addition, DMAP alter packages employing the alter control cards will be much less susceptible to future changes in rigid format DMAPs than alter packages employing the standard ALTER control cards. The usage of the cards is illustrated by examples.

  7. 10 CFR 71.33 - Package description.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Classification as Type B(U), Type B(M), or fissile material packaging; (2) Gross weight; (3) Model number; (4... absorbers or moderators, and the atomic ratio of moderator to fissile constituents; (5) Maximum normal...

  8. Assembling an ignimbrite: Compositionally defined eruptive packages in the 1912 Valley of Ten Thousand Smokes ignimbrite, Alaska

    USGS Publications Warehouse

    Fierstein, J.; Wilson, C.J.N.

    2005-01-01

    The 1912 Valley of Ten Thousand Smokes (VTTS) ignimbrite was constructed from 9 compositionally distinct, sequentially emplaced packages, each with distinct proportions of rhyolite (R), dacite (D), and andesite (A) pumices that permit us to map package boundaries and flow paths from vent to distal extents. Changing pumice proportions and interbedding relationships link ignimbrite formation to coeval fall deposition during the first ???16 h (Episode I) of the eruption. Pumice compositional proportions in the ignimbrite were estimated by counts on ???100 lapilli at multiple levels in vertical sections wherever accessible and more widely over most of the ignimbrite surface in the VTTS. The initial, 100% rhyolite ignimbrite package (equivalent to regional fall Layer A and occupying ???3.5 h) was followed by packages with increasing proportions of andesite, then dacite, emplaced over ???12.5 h and equivalent to regional fall Layers B1-B3. Coeval fall deposits are locally intercalated with the ignimbrite and show parallel changes in R:D (rhyolite:dacite) proportions, but lack significant amounts of andesite. Andesite was thus dominantly a low-fountaining component in the eruption column and is preferentially represented in packages filling the VTTS north of the vent. The most extensive packages (3 and 4) occur in B1 and early B2 times where flow mobility and volume were optimized; earlier all-rhyolite flows (Package 1) were highly energetic but less voluminous, while later packages (5-9) were both less voluminous and emplaced at lower velocities. Package boundaries are expressed as one or more of the following: sharp color changes corresponding to compositional variations; persistent finer-grained basal parts of flow units; compaction swales filled by later packages; erosional channels cut by the flows that fill them; lobate accumulations of one package; and (mostly south of the vent) intercalated fall deposit layers. Clear flow-unit boundaries are best developed between ignimbrite of non-successive packages, indicating time breaks of tens of minutes to hours. Less well-defined stratification may represent rapidly emplaced successive flow units but often changes over short distances and indicates variations in localized depositional conditions. ?? 2005 Geological Society of America.

  9. A novel motif in the yeast mitochondrial dynamin Dnm1 is essential for adaptor binding and membrane recruitment

    PubMed Central

    Bui, Huyen T.; Karren, Mary A.; Bhar, Debjani

    2012-01-01

    To initiate mitochondrial fission, dynamin-related proteins (DRPs) must bind specific adaptors on the outer mitochondrial membrane. The structural features underlying this interaction are poorly understood. Using yeast as a model, we show that the Insert B domain of the Dnm1 guanosine triphosphatase (a DRP) contains a novel motif required for association with the mitochondrial adaptor Mdv1. Mutation of this conserved motif specifically disrupted Dnm1–Mdv1 interactions, blocking Dnm1 recruitment and mitochondrial fission. Suppressor mutations in Mdv1 that restored Dnm1–Mdv1 interactions and fission identified potential protein-binding interfaces on the Mdv1 β-propeller domain. These results define the first known function for Insert B in DRP–adaptor interactions. Based on the variability of Insert B sequences and adaptor proteins, we propose that Insert B domains and mitochondrial adaptors have coevolved to meet the unique requirements for mitochondrial fission of different organisms. PMID:23148233

  10. 7 CFR Exhibit B to Subpart A of... - Notice of Change in Interest Rate

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 14 2010-01-01 2009-01-01 true Notice of Change in Interest Rate B Exhibit B to... Interest Rate (insert date) Notice of Change in Interest Rate (insert borrower's address) Re: □ □ Fund code... ___, for the original amount of ___ dollars ($___) provides for a change in interest rate for a limited...

  11. Molecular analysis of a chromosome-carried erm(B) gene and its flanking insertion points in Lactobacillus johnsonii G41.

    PubMed

    Flórez, Ana Belén; Ammor, Mohammed Salim; Delgado, Susana; Mayo, Baltasar

    2006-12-01

    An erm(B) gene carried on the Lactobacillus johnsonii G41 chromosome and the upstream and downstream regions were fully sequenced. Apparently, a 1,495-bp segment of pRE25 from Enterococcus faecalis carrying the erm(B) gene became inserted, by an unknown mechanism, into the L. johnsonii chromosome.

  12. The use of transient evoked otoacoustic emissions as a hearing screen following grommet insertion.

    PubMed

    Dale, O T; McCann, L J; Thio, D; Wells, S C; Drysdale, A J

    2011-07-01

    This study aimed to evaluate the sensitivity of transient evoked otoacoustic emission testing as a screening tool for hearing loss in children, after grommet insertion. A prospective study was conducted of 48 children (91 ears) aged three to 16 years who had undergone grommet insertion for glue ear. At post-operative review, pure tone audiometry was performed followed by transient evoked otoacoustic emission testing. Outcomes for both tests, in each ear, were compared. The pure tone audiometry threshold was ≤ 20 dB in 85 ears (93.4 per cent), 25 dB in two ears (2.2 per cent) and ≥ 30 dB in four ears (4.4 per cent). Transient evoked otoacoustic emissions were detected in 69 ears (75.8 per cent). The sensitivity of transient evoked otoacoustic emission testing for detecting hearing loss was 100 per cent for ≥ 30 dB loss but only 66.7 per cent for ≥ 25 dB loss. Transient evoked otoacoustic emission testing offers a sensitive means of detecting hearing loss of ≥ 30 dB following grommet insertion in children. However, the use of such testing as a screening tool may miss some cases of mild hearing loss.

  13. 9977 TYPE B PACKAGING INTERNAL DATA COLLECTION FEASIBILITY TESTING - MAGNETIC FIELD COMMUNICATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shull, D.

    2012-06-18

    The objective of this report is to document the findings from proof-of-concept testing performed by the Savannah River National Laboratory (SRNL) R&D Engineering and Visible Assets, Inc. for the DOE Packaging Certification Program (PCP) to determine if RuBee (IEEE 1902.1) tags and readers could be used to provide a communication link from within a drum-style DOE certified Type B radioactive materials packaging. A Model 9977 Type B Packaging was used to test the read/write capability and range performance of a RuBee tag and reader. Testing was performed with the RuBee tags placed in various locations inside the packaging including insidemore » the drum on the outside of the lid of the containment vessel and also inside of the containment vessel. This report documents the test methods and results. A path forward will also be recommended.« less

  14. Sequence variations of the partially dominant DELLA gene Rht-B1c in wheat and their functional impacts

    PubMed Central

    Ma, Zhengqiang

    2013-01-01

    Rht-B1c, allelic to the DELLA protein-encoding gene Rht-B1a, is a natural mutation documented in common wheat (Triticum aestivum). It confers variation to a number of traits related to cell and plant morphology, seed dormancy, and photosynthesis. The present study was conducted to examine the sequence variations of Rht-B1c and their functional impacts. The results showed that Rht-B1c was partially dominant or co-dominant for plant height, and exhibited an increased dwarfing effect. At the sequence level, Rht-B1c differed from Rht-B1a by one 2kb Veju retrotransposon insertion, three coding region single nucleotide polymorphisms (SNPs), one 197bp insertion, and four SNPs in the 1kb upstream sequence. Haplotype investigations, association analyses, transient expression assays, and expression profiling showed that the Veju insertion was primarily responsible for the extreme dwarfing effect. It was found that the Veju insertion changed processing of the Rht-B1c transcripts and resulted in DELLA motif primary structure disruption. Expression assays showed that Rht-B1c caused reduction of total Rht-1 transcript levels, and up-regulation of GATA-like transcription factors and genes positively regulated by these factors, suggesting that one way in which Rht-1 proteins affect plant growth and development is through GATA-like transcription factor regulation. PMID:23918966

  15. A MEMS disk resonator-based band pass filter electrical equivalent circuit simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sundaram, G. M.; Angira, Mahesh; Gupta, Navneet

    In this paper, coupled beam bandpass Disk filter is designed for 1 MHz bandwidth. Filter electrical equivalent circuit simulation is performed using circuit simulators. Important filter parameters such as insertion loss, shape factor and Q factor aresetimated using coventorware simulation. Disk resonator based radial contour mode filter provides 1.5 MHz bandwidth and unloaded quality factor of resonator and filter as 233480, 21797 respectively. From the simulation result it’s found that insertion loss minimum is 151.49 dB, insertion loss maximum is 213.94 dB, and 40 dB shape factor is 4.17.

  16. Demonstration of Compact and Low-Loss Athermal Arrayed-Waveguide Grating Module Based on 2.5%-Δ Silica-Based Waveguides

    NASA Astrophysics Data System (ADS)

    Maru, Koichi; Abe, Yukio; Uetsuka, Hisato

    2008-10-01

    We demonstrated a compact and low-loss athermal arrayed-waveguide grating (AWG) module utilizing silica-based planar lightwave circuit (PLC) technology. Spot-size converters based on a vertical ridge-waveguide taper were integrated with a 2.5%-Δ athermal AWG to reduce the loss at chip-to-fiber interface. Spot-size converters based on a segmented core were formed around resin-filled trenches for athermalization formed in the slab to reduce the diffraction loss at the trenches. A 16-channel athermal AWG module with 100-GHz channel spacing was fabricated. The use of a 2.5%-Δ athermal chip with a single-side fiber array enabled a compact package of the size of 41.6×16.6×4.5 mm3. Athermal characteristics and a small insertion loss of 3.5-3.8 dB were obtained by virtue of low fiber-to-chip coupling loss and athermalization with low excess loss.

  17. Unlocking Short Read Sequencing for Metagenomics

    DOE PAGES

    Rodrigue, Sébastien; Materna, Arne C.; Timberlake, Sonia C.; ...

    2010-07-28

    We describe an experimental and computational pipeline yielding millions of reads that can exceed 200 bp with quality scores approaching that of traditional Sanger sequencing. The method combines an automatable gel-less library construction step with paired-end sequencing on a short-read instrument. With appropriately sized library inserts, mate-pair sequences can overlap, and we describe the SHERA software package that joins them to form a longer composite read.

  18. Consumer and health literacy: The need to better design tobacco-cessation product packaging, labels, and inserts.

    PubMed

    Weiss, Stephanie M; Smith-Simone, Stephanie Y

    2010-03-01

    Tobacco-cessation product packaging and instruction materials may not be appropriate for some smokers and may contribute to the underuse and misuse of evidence-based treatments. The dual goals of this project are to analyze literacy levels of Food and Drug Administration (FDA)-approved and non-approved tobacco-cessation product packaging, directions, and claims, and to identify and categorize claims found on product packaging. The Campaign for Tobacco Free Kids (CTFK) maintains the Quitting and Reducing Tobacco Use Inventory of Products (QuiTIP) database, which catalogs products marketed and sold to consumers to reduce or quit use of tobacco products. It also includes all medications approved by the FDA for tobacco cessation as well as a sample of non-approved products such as homeopathic, herbal, nutritional, or dietary supplements commonly marketed as either cessation aids or alternative tobacco/nicotine products. This paper assesses the reading levels required to understand product packaging, labeling, and instructions using the Simple Measure of Gobbledygook (SMOG) and identifies claims on the product package labels using standard qualitative methods. Key findings show that the average reading levels needed to understand instructions for both FDA-approved and non-approved cessation products are above the reading levels recommended to ensure maximum comprehension. Improving the packaging and directions of evidence-based tobacco-cessation products so that they are preferably at or below a fifth-grade reading level, along with using consumer-based design principles to develop packaging, may help smokers take advantage of and correctly use products that will greatly increase their chances of successful quitting. 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  19. Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

    NASA Technical Reports Server (NTRS)

    Ghaffaroam. Reza

    2014-01-01

    Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

  20. Variation in Prescribing Patterns and Therapeutic Drug Monitoring of Intravenous Busulfan in Pediatric Hematopoietic Cell Transplant Recipients

    PubMed Central

    McCune, Jeannine S.; Baker, K. Scott; Blough, David K.; Gamis, Alan; Bemer, Meagan J.; Kelton-Rehkopf, Megan C.; Winter, Laura; Barrett, Jeffrey S.

    2016-01-01

    Personalizing intravenous (IV) busulfan doses in children using therapeutic drug monitoring (TDM) is an integral component of hematopoietic cell transplant. The authors sought to characterize initial dosing and TDM of IV busulfan, along with factors associated with busulfan clearance, in 729 children who underwent busulfan TDM from December 2005 to December 2008. The initial IV busulfan dose in children weighing ≤12 kg ranged 4.8-fold, with only 19% prescribed the package insert dose of 1.1 mg/kg. In those children weighing >12 kg, the initial dose ranged 5.4-fold, and 79% were prescribed the package insert dose. The initial busulfan dose achieved the target exposure in only 24.3% of children. A wide range of busulfan exposures were targeted for children with the same disease (eg, 39 target busulfan exposures for the 264 children diagnosed with acute myeloid leukemia). Considerable heterogeneity exists regarding when TDM is conducted and the number of pharmacokinetic samples obtained. Busulfan clearance varied by age and dosing frequency but not by underlying disease. The authors’ group is currently evaluating how using population pharmacokinetics to optimize initial busulfan dose and TDM (eg, limited sampling schedule in conjunction with maximum a posteriori Bayesian estimation) may affect clinical outcomes in children. PMID:23444282

  1. 49 CFR Appendix B to Part 173 - Procedure for Testing Chemical Compatibility and Rate of Permeation in Plastic Packaging and...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other..., App. B Appendix B to Part 173—Procedure for Testing Chemical Compatibility and Rate of Permeation in... °C. (64 °F.) b. Test Method 2: 28 days at a temperature no lower than 50 °C. (122 °F.) c. Test Method...

  2. A small and efficient dimerization/packaging signal of rat VL30 RNA and its use in murine leukemia virus-VL30-derived vectors for gene transfer.

    PubMed Central

    Torrent, C; Gabus, C; Darlix, J L

    1994-01-01

    Retroviral genomes consist of two identical RNA molecules associated at their 5' ends by the dimer linkage structure located in the packaging element (Psi or E) necessary for RNA dimerization in vitro and packaging in vivo. In murine leukemia virus (MLV)-derived vectors designed for gene transfer, the Psi + sequence of 600 nucleotides directs the packaging of recombinant RNAs into MLV virions produced by helper cells. By using in vitro RNA dimerization as a screening system, a sequence of rat VL30 RNA located next to the 5' end of the Harvey mouse sarcoma virus genome and as small as 67 nucleotides was found to form stable dimeric RNA. In addition, a purine-rich sequence located at the 5' end of this VL30 RNA seems to be critical for RNA dimerization. When this VL30 element was extended by 107 nucleotides at its 3' end and inserted into an MLV-derived vector lacking MLV Psi +, it directed the efficient encapsidation of recombinant RNAs into MLV virions. Because this VL30 packaging signal is smaller and more efficient in packaging recombinant RNAs than the MLV Psi + and does not contain gag or glyco-gag coding sequences, its use in MLV-derived vectors should render even more unlikely recombinations which could generate replication-competent viruses. Therefore, utilization of the rat VL30 packaging sequence should improve the biological safety of MLV vectors for human gene transfer. Images PMID:8289369

  3. 49 CFR 176.156 - Defective packages.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... packages. (a) No leaking, broken, or otherwise defective package containing Class 1 (explosive) materials.... (b) No Class 1 (explosive) material, which for any reason has deteriorated or undergone a change of...

  4. Development of a reliable method to assess footwear comfort during running.

    PubMed

    Mündermann, Anne; Nigg, Benno M; Stefanyshyn, Darren J; Humble, R Neil

    2002-08-01

    The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used. Copyright 2002 Elsevier Science B.V.

  5. 29 CFR 99.320 - Report submission.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... completed and the data collection form and reporting package shall be submitted within the earlier of 30... the data elements prescribed by OMB. (c) Reporting package. The reporting package shall include the... data collection form described in paragraph (b) of this section and one copy of the reporting package...

  6. 29 CFR 99.320 - Report submission.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... completed and the data collection form and reporting package shall be submitted within the earlier of 30... the data elements prescribed by OMB. (c) Reporting package. The reporting package shall include the... data collection form described in paragraph (b) of this section and one copy of the reporting package...

  7. Surface acoustic wave resonators

    NASA Astrophysics Data System (ADS)

    Avitabile, Gianfranco; Roselli, Luca; Atzeni, Carlo; Manes, Gianfranco

    1991-10-01

    The development of surface acoustic wave (SAW) resonators is reviewed with attention given to the design of a simulation package for CAD-assisted SAW resonator design. Basic design configurations and operation parameters are set forth for the SAW resonators including the phase of the reflection factor, evaluation of the stopband center frequency, stopband width, and the free propagation speed. The use of synchronous designs is shown to reduce device sensitivity to variations in the technological process but generate higher insertion losses. The existence of transverse modes and propagation losses is shown to affect the rejection of spurious modes and the achievement of low insertion losses. Several SAW resonators are designed and fabricated with the CAD process, and the resonators in the VHF-UHF bands perform in a manner predicted by simulated results.

  8. 49 CFR 172.310 - Class 7 (radioactive) materials.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... States company or agency is the symbol “USA.” (d) Each package which conforms to a Type B(U) or Type B(M... “USA” in conjunction with the specification marking, or other package certificate identification. (See...

  9. 49 CFR 172.310 - Class 7 (radioactive) materials.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... States company or agency is the symbol “USA.” (d) Each package which conforms to a Type B(U) or Type B(M... “USA” in conjunction with the specification marking, or other package certificate identification. (See...

  10. 49 CFR 172.310 - Class 7 (radioactive) materials.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... States company or agency is the symbol “USA.” (d) Each package which conforms to a Type B(U) or Type B(M... “USA” in conjunction with the specification marking, or other package certificate identification. (See...

  11. [Analysis of optimal plan of multiple acupuncture manipulations for shoulder pain after stroke at different stages].

    PubMed

    Chen, Dachun; Gao, Jianyu; Chen, Lu; Hao, Zhuanzhuan; Fan, Gangqi

    2015-12-01

    To observe the effects between acupuncture combined with rehabilitation and simple rehabilitation for shoulder pain after stroke, and to select the best plan of acupuncture manipulations at different stages by orthogonal design. Ninety patients were treated with comprehensive rehabilitation, and nine cases without acupuncture were arranged into a control group. Eighty-one patients of orthogonal design were applied by acupuncture with the same acupoints and course. The VAS score and its weighted value were regarded as the observation indices,and the effects between the acupuncture group and the control group were compared. The optimal plans of acupuncture manipulations of the early stage and the later stage were chosen after the first course treatment and the third course treatment separately. The acupuncture depth (factor A:A: shallow depth less than 25 mm, A(II): modest depth 25-40 mm, A(III): deep depth 40-50 mm), the acupuncture angle (factor B:B(I): perpendicular insertion, B(II): horizontal insertion, B(III): oblique insertion), needle manipulated frequency (factor C: C(I): zero time, C(II): one time, C(III): three times) and needle retained time(factor D:D(I):20 min, D(II): 30 min, D(III): 60 min) were studied. The differences among all factors and the diversity among major factors at different stages were analyzed. (1) Acupuncture combined with rehabilitation at the early and the later stage acquired better improvement than simple rehabilitation (all P < 0.01). (2) The optimal acupuncture manipulation plan at the early stage was A(III) B(III) C(I) D(I), which was deep acupuncture and oblique insertion for 20 min with zero-time manipulation; the optimal acupuncture manipulation plan at the later stage was A(III) B(III) C(III) D(I), which was deep acupuncture and oblique insertion for 20 min with three-time manipulation. (3) There was significance for acupuncture depth and angle at the early stage (both P < 0.01) and there was significance for insertion depth, acupuncture angle and manipulating frequency at the later stage (all P < 0.05). (4) At the early stage, the insertion depth was statistically significant between A(I) and A(II), A(I) and A(III), A(II) and A(III) (P < 0.05, P < 0.01), and the statistical significance was existed between B(I) and B(III) (P < 0.01). At the later stage, the insertion depth was statistically significant between A(I) and A(III), A(III) and A(II), A(I) and A(II) (P < 0.05, P < 0.01), and the statistical significance was existed between C(I) and C(III), C(II) and C(III) (P < 0.05). Acupuncture combined with rehabilitation acquire apparent effect for shoulder pain after stroke. At the early stage,the optimal plan is deep and oblique insertion for 20 min with zero-time manipulation. At the later stage, the best plan is deep and oblique insertion for 20 min with 3-time manipulation.

  12. 48 CFR 816.504 - Indefinite-quantity contracts.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... issue a solicitation for estimated quantities, the contracting officer shall insert the clause at 852.216-70, Estimated quantities. (b) The contracting officer shall insert the Alternate I clause at 852.216-70 in solicitations for bulk coal. (c) The contracting officer shall insert the Alternate II...

  13. Non-blocking four-port optical router based on thermooptic silicon microrings

    NASA Astrophysics Data System (ADS)

    Dang, Pei-pei; Li, Cui-ting; Zheng, Wen-xue; Zheng, Chuan-tao; Wang, Yi-ding

    2016-07-01

    By using silicon-on-insulator (SOI) platform, 12 channel waveguides, and four parallel-coupling one-microring resonator routing elements, a non-blocking four-port optical router is proposed. Structure design and optimization are performed on the routing elements at 1 550 nm. At drop state with a power consumption of 0 mW, the insertion loss of the drop port is less than 1.12 dB, and the crosstalk between the two output ports is less than -28 dB; at through state with a power consumption of 22 mW, the insertion loss of the through port is less than 0.45 dB, and the crosstalk between the two output ports is below -21 dB. Routing topology and function are demonstrated for the four-port optical router. The router can work at nine non-blocking routing states using the thermo-optic (TO) effect of silicon for tuning the resonance of each switching element. Detailed characterizations are presented, including output spectrum, insertion loss, and crosstalk. According to the analysis on all the data links of the router, the insertion loss is within the range of 0.13—3.36 dB, and the crosstalk is less than -19.46 dB. The router can meet the need of large-scale optical network-on-chip (ONoC).

  14. Rapid immunization effects of a new type of 60 μg hepatitis B vaccine compared with traditional 20 μg hepatitis B vaccines in adults.

    PubMed

    Wang, Huai; Cai, Binyu; Rao, Delong; Liu, Min; Li, Yabin; Liang, Xiaofeng; Cui, Fuqiang; Zhang, Guomin; Wang, Fuzhen; Pang, Xinghuo; Nie, Li; Qiu, Qian; Wu, Jiang; Li, Liqiu; Huang, Fang; Zhang, Wei

    2016-11-01

    The widely recommended standard schedule of hepatitis B vaccine for adults is months 0, 1 and 6, which takes 6 months to complete. Rapid completion of one vaccination schedule is important to adults because of its low compliance with follow-up doses. A new type of 60 μg Hepatitis B vaccine, made by Shenzhen Kangtai Biological Products Co., LTD., is originally recommended for low or non-responders. The objective of this clinical trial was to test whether this 60 μg hepatitis B vaccine could be used in primary immune population and what is its level of immunogenicity and safety compared with other hepatitis B vaccines. This is a 2-center randomized controlled study. A total of 1169 healthy adults aged between 25 and 55 who tested negative for HBsAg, anti-HBs, and anti-HBc were eligible for the study and were enrolled from relatively fixed and stable sites, such as villages, schools and large enterprises et al in Xuanhua county in Hebei province and Huaibei county in Anhui province. They were randomized to group A (20 μg Engerix-B® with 0, 1, 6 month intervals), group B (20 μg Kangtai hepatitis B vaccine with 0, 1, 6 month intervals), group C (60 μg Kangtai hepatitis B vaccine with 0, 2 month intervals) and group D (20 μg Huabei hepatitis B vaccine made by recombinant DNA techniques in CHO cell with 0, 1, 6 month intervals). In group A, B and D, every study object's blood sample was collected in the second month after their final injection to test the anti-HBs levels; while in group C, the blood sample was collected in the second month after the first and the second injection to test the anti-HBs levels. Adverse events were collected after each dose to assess the vaccines' safety. The seroprotection rates were 93.17%, 97.23%, 93.54% and 98.98% respectively and the geometric mean titers (GMTs) were 1033.38 mIU/ml, 600.75 mIU/ml, 265.69 mIU/ml and 1627.05 mIU/ml in group A,B,C and D respectively. The difference of seroprotection rate among the 4 groups was statistically significant (χ 2 = 17.26, P<0.05). The difference of titers of anti-HBs among the 4 groups was statistically significant (H = 162.42, P<0.05). BMI, age (older than 40) and smoking were the influence factors of anti-HBs levels on 60 μg hepatitis B vaccine. 60 μg hepatitis B vaccine has a satisfactory safety and seroprotection rate in adult, It could be used in rapid adult hepatitis B immunization.

  15. 76 FR 60013 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-28

    ... per 35.17(b): Amendment--docket number inserted 09192011 to be effective 10/11/2011. Filed Date: 09/19... Northeast LLC submits tariff filing per 35.17(b): Amendment--docket number inserted 09192011 to be effective... Commission's eLibrary system by clicking on the links or querying the docket number. Any person desiring to...

  16. Investigation of AWG demultiplexer based SOI for CWDM application

    NASA Astrophysics Data System (ADS)

    Juhari, Nurjuliana; Susthitha Menon, P.; Shaari, Sahbudin; Annuar Ehsan, Abang

    2017-11-01

    9-channel Arrayed Waveguide Grating (AWG) demultiplexer for conventional and tapered structure were simulated using beam propagation method (BPM) with channel spacing of 20 nm. The AWG demultiplexer was design using high refractive index (n 3.47) material namely silicon-on-insulator (SOI) with rib waveguide structure. The characteristics of insertion loss, adjacent crosstalk and output spectrum response at central wavelength of 1.55 μm for both designs were compared and analyzed. The conventional AWG produced a minimum insertion loss of 6.64 dB whereas the tapered AWG design reduced the insertion loss by 2.66 dB. The lowest adjacent crosstalk value of -16.96 dB was obtained in the conventional AWG design and this was much smaller compared to the tapered AWG design where the lowest crosstalk value is -17.23 dB. Hence, a tapered AWG design significantly reduces the insertion loss but has a slightly higher adjacent crosstalk compared to the conventional AWG design. On the other hand, the output spectrum responses that are obtained from both designs were close to the Coarse Wavelength Division Multiplexing (CWDM) wavelength grid.

  17. Study of low insertion loss and miniaturization wavelet transform and inverse transform processor using SAW devices.

    PubMed

    Jiang, Hua; Lu, Wenke; Zhang, Guoan

    2013-07-01

    In this paper, we propose a low insertion loss and miniaturization wavelet transform and inverse transform processor using surface acoustic wave (SAW) devices. The new SAW wavelet transform devices (WTDs) use the structure with two electrode-widths-controlled (EWC) single phase unidirectional transducers (SPUDT-SPUDT). This structure consists of the input withdrawal weighting interdigital transducer (IDT) and the output overlap weighting IDT. Three experimental devices for different scales 2(-1), 2(-2), and 2(-3) are designed and measured. The minimum insertion loss of the three devices reaches 5.49dB, 4.81dB, and 5.38dB respectively which are lower than the early results. Both the electrode width and the number of electrode pairs are reduced, thus making the three devices much smaller than the early devices. Therefore, the method described in this paper is suitable for implementing an arbitrary multi-scale low insertion loss and miniaturization wavelet transform and inverse transform processor using SAW devices. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. KSC-97PC1277

    NASA Image and Video Library

    1997-08-22

    In the Payload Hazardous Servicing Facility (PHSF), Dan Maynard, a Jet Propulsion Laboratory technician, inserts the Digital Video Disk (DVD) into a shallow cavity between two pieces of aluminum that will protect it from micrometeoroid impacts. The package will be mounted to the side of the two-story-tall spacecraft beneath a pallet carrying cameras and other space instruments that will be used to study the Saturnian system. A specially designed, multicolored patch of thermal blanket material will be installed over the disk package. Along with the spacecraft, the disk will reside in Saturn's orbit centuries after the primary mission is completed in July 2008. The Cassini mission is managed for NASA's Office of Space Science, Washington, D.C., by the Jet Propulsion Laboratory, a division of the California Institute of Technology

  19. Keeping waived tests simple.

    PubMed

    2004-01-01

    Laboratories performing waived testing must follow the manufacturer's instructions as well as good laboratory practices to ensure that test results are reliable. Four things to concentrate on to maximize the performance and reliability of waived tests are to: 1. Read and follow the information found in the package inserts. 2. Follow the manufacturer's recommendations for running quality control. 3. Train staff members to perform tests correctly. 4. Follow established policies and procedures for patient testing in the practice.

  20. Field Level Computer Exploitation Package

    DTIC Science & Technology

    2007-03-01

    to take advantage of the data retrieved from the computer. Major Barge explained that if a tool could be designed that nearly anyone could use...the study of network forensics. This has become a necessity because of the constantly growing eCommerce industry and the stiff competition between...Security. One big advantage that Insert has is the fact that it is quite small compared to most bootable CDs. At only 60 megabytes it can be burned

  1. Technical Review Report for the Mound 1KW Package Safety Analysis Report for Packaging Waiver for the Use of Modified Primary Containment Vessel (PCV)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, M; Hafner, R

    2008-05-05

    This Technical Review Report (TRR) documents the review, performed by the Lawrence Livermore National Laboratory (LLNL) staff, at the request of the U.S. Department of Energy (DOE), on the Waiver for the Use of Modified Primary Containment Vessels (PCV). The waiver is to be used to support a limited number of shipments of fuel for the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) Project in support of the National Aeronautics and Space Administration's (NASA's) Mars Science Laboratory (MSL) mission. Under the waiver, an inventory of existing national security PCVs will be converted to standard PCVs. Both types of PCVs are currently approvedmore » for use by the Office of Nuclear Energy. LLNL has previously reviewed the national security PCVs under Mound 1KW Package Safety Analysis Report for Packaging, Addendum No. 1, Revision c, dated June 2007 (Addendum 1). The safety analysis of the package is documented in the Safety Analysis Report for Packaging (SARP) for the Mound 1KW Package (i.e., the Mound 1KW SARP, or the SARP) where the standard PCVs have been reviewed by LLNL. The Mound 1KW Package is certified by DOE Certificate of Compliance (CoC) number USA/9516/B(U)F-85 for the transportation of Type B quantities of plutonium heat source material. The waiver requests an exemption, claiming safety equivalent to the requirements specified in 10 CFR 71.12, Specific Exemptions, and will lead to a letter amendment to the CoC. Under the waiver, the Office of Radioisotope Power Systems, NE-34, is seeking an exemption from 10 CFR 71.19(d)(1), Previously Approved Package,[5] which states: '(d) NRC will approve modifications to the design and authorized contents of a Type B package, or a fissile material package, previously approved by NRC, provided--(1) The modifications of a Type B package are not significant with respect to the design, operating characteristics, or safe performance of the containment system, when the package is subjected to the tests specified in {section}71.71 and 71.73.' The LLNL staff had previously reviewed a request from Idaho National Laboratory (INL) to reconfigure national security PCVs to standard PCVs. With a nominal 50% reduction in both the height and the volume, the LLNL staff initially deemed the modifications to be significant, which would not be allowed under the provisions of 10 CFR 71.19(d)(1)--see above. As a follow-up, the DOE requested additional clarification from the Nuclear Regulatory Commission (NRC). The NRC concluded that the reconfiguration would be a new fabrication, and that an exemption to the regulations would be required to allow its use, as per the requirements specified in 10 CFR 71.19(c)(1), Previously Approved Package: '(c) A Type B(U) package, a Type B(M) package, or a fissile material package previously approved by the NRC with the designation '-85' in the identification number of the NRC CoC, may be used under the general license of {section}71.17 with the following additional conditions: (1) Fabrication of the package must be satisfactorily completed by December 31, 2006, as demonstrated by application of its model number in accordance with 71.85(c).' Although the preferred approach toward the resolution of this issue would be for the applicant to submit an updated SARP, the applicant has stated that the process of updating the Model Mound 1KW Package SARP is a work that is in progress, but that the updated SARP is not yet ready for submittal. The applicant has to provide a submittal, proving that the package meets the '-96' requirements of International Atomic Energy Agency (IAEA) Safety Standards Series No. TS-R-1, in order to fabricate approved packagings after December 31, 2006. The applicant has further stated that all other packaging features, as described in the currently approved Model Mound 1KW Package SARP, remain unchanged. This report documents the LLNL review of the waiver request. The specific review for each SARP Chapter is documented.« less

  2. The effects of atmospheric pressure cold plasma treatment on microbiological, physical-chemical and sensory characteristics of vacuum packaged beef loin.

    PubMed

    Bauer, A; Ni, Y; Bauer, S; Paulsen, P; Modic, M; Walsh, J L; Smulders, F J M

    2017-06-01

    Effects on vacuum packaged and non-packaged beef longissimus samples exposed to atmospheric cold plasma (ACP) generated at different powers were studied over a 10day period of vacuum-, and a subsequent 3day period of aerobic storage. Exposure of non-covered beef samples under high power ACP conditions resulted in increased a*, b*, Chroma and Hue values, but ACP treatment of packaged loins did not impact colour (L*, a*, b*, Chroma, Hue), lipid peroxidation, sarcoplasmic protein denaturation, nitrate/nitrite uptake, or myoglobin isoform distribution. Colour values measured after 3days of aerobic storage following unpackaging (i.e. 20days post-mortem) were similar and all compliant with consumer acceptability standards. Exposure to ACP of the polyamide-polyethylene packaging film inoculated with Staphylococcus aureus, Listeria monocytogenes and two Escherichia coli strains resulted in >2 log reduction without affecting the integrity of the packaging matrix. Results indicate that ACP can reduce microbial numbers on surfaces of beef packages without affecting characteristics of the packaged beef. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. The use of a newspaper insertion to promote DIY testing of vision in India.

    PubMed

    Murthy, G V; Gupta, S K; Dada, V K; Pant, T D; Savita, C; Sanga, L; Neena, J

    2001-08-01

    The mass media have the potential to motivate people to participate in self appraisal of their own health status. An innovative communication package was designed to help people to examine vision at home. The impact of publishing the "do it yourself" (DIY) kit in Indian newspapers was evaluated. A pretested bilingual vision testing kit was published in three newspapers. The kit comprised four tumbling Es corresponding to 6/12 line of Snellen's optotypes. Directions on using the kit were enclosed. 3 -7 days after publication of the kit, a telephone survey of newspaper readers was undertaken to evaluate the impact and cost effectiveness. 603 people were contacted over the telephone. 125 (20.73%) subscribed to the newspaper carrying the DIY insertion. 43.2% (54) noticed the insertion of which 88.89% (48) read the enclosed instructions carefully. 58.33% respondents felt sufficiently motivated to contact an ophthalmologist. Graduates had a 3.83 times higher probability of reading the communication insertion compared with others. Differences in relation to other demographic variables were not statistically significant. Newspapers are an excellent medium for communicating self appraisal kits for vision testing. The medium is cost effective and has significant reach in the urban agglomerates of India.

  4. The use of a newspaper insertion to promote DIY testing of vision in India

    PubMed Central

    Murthy, G; Gupta, S. K.; Dada, V. K.; Pant, T. D.; Savita, C.; Sanga, L.; Neena, J.

    2001-01-01

    BACKGROUND—The mass media have the potential to motivate people to participate in self appraisal of their own health status. An innovative communication package was designed to help people to examine vision at home. The impact of publishing the "do it yourself" (DIY) kit in Indian newspapers was evaluated.
METHODS—A pretested bilingual vision testing kit was published in three newspapers. The kit comprised four tumbling Es corresponding to 6/12 line of Snellen's optotypes. Directions on using the kit were enclosed. 3 -7 days after publication of the kit, a telephone survey of newspaper readers was undertaken to evaluate the impact and cost effectiveness.
RESULTS—603 people were contacted over the telephone. 125 (20.73%) subscribed to the newspaper carrying the DIY insertion. 43.2% (54) noticed the insertion of which 88.89% (48) read the enclosed instructions carefully. 58.33% respondents felt sufficiently motivated to contact an ophthalmologist. Graduates had a 3.83 times higher probability of reading the communication insertion compared with others. Differences in relation to other demographic variables were not statistically significant.
CONCLUSIONS—Newspapers are an excellent medium for communicating self appraisal kits for vision testing. The medium is cost effective and has significant reach in the urban agglomerates of India.

 PMID:11466254

  5. 40 CFR 157.32 - Standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... REQUIREMENTS FOR PESTICIDES AND DEVICES Child-Resistant Packaging § 157.32 Standards. (a) Effectiveness standard. The child-resistant packaging, when tested by the protocol specified in 16 CFR 1700.20, shall meet the effectiveness specifications in 16 CFR 1700.15(b). (b) Compatibility standard. The child...

  6. Protein Interactions and Localization of the Escherichia coli Accessory Protein HypA during Nickel Insertion to [NiFe] Hydrogenase*

    PubMed Central

    Chan Chung, Kim C.; Zamble, Deborah B.

    2011-01-01

    Nickel delivery during maturation of Escherichia coli [NiFe] hydrogenase 3 includes the accessory proteins HypA, HypB, and SlyD. Although the isolated proteins have been characterized, little is known about how they interact with each other and the hydrogenase 3 large subunit, HycE. In this study the complexes of HypA and HycE were investigated after modification with the Strep-tag II. Multiprotein complexes containing HypA, HypB, SlyD, and HycE were observed, consistent with the assembly of a single nickel insertion cluster. An interaction between HypA and HycE did not require the other nickel insertion proteins, but HypB was not found with the large subunit in the absence of HypA. The HypA-HycE complex was not detected in the absence of the HypC or HypD proteins, involved in the preceding iron insertion step, and this interaction is enhanced by nickel brought into the cell by the NikABCDE membrane transporter. Furthermore, without the hydrogenase 1, 2, and 3 large subunits, complexes between HypA, HypB, and SlyD were observed. These results support the hypothesis that HypA acts as a scaffold for assembly of the nickel insertion proteins with the hydrogenase precursor protein after delivery of the iron center. At different stages of the hydrogenase maturation process, HypA was observed at or near the cell membrane by using fluorescence confocal microscopy, as was HycE, suggesting membrane localization of the nickel insertion event. PMID:22016389

  7. The Transposable Element Mariner Mediates Germline Transformation in Drosophila Melanogaster

    PubMed Central

    Lidholm, D. A.; Lohe, A. R.; Hartl, D. L.

    1993-01-01

    A vector for germline transformation in Drosophila melanogaster was constructed using the transposable element mariner. The vector, denoted pMlwB, contains a mariner element disrupted by an insertion containing the wild-type white gene from D. melanogaster, the β-galactosidase gene from Escherichia coli and sequences that enable plasmid replication and selection in E. coli. The white gene is controlled by the promoter of the D. melanogaster gene for heat-shock protein 70, and the β-galactosidase gene is flanked upstream by the promoter of the transposable element P as well as that of mariner. The MlwB element was introduced into the germline of D. melanogaster by co-injection into embryos with an active mariner element, Mos1, which codes for a functional transposase and serves as a helper. Two independent germline insertions were isolated and characterized. The results show that the MlwB element inserted into the genome in a mariner-dependent manner with the termini of the inverted repeats inserted at a TA dinucleotide. Both insertions exhibit an unexpected degree of germline and somatic stability, even in the presence of an active mariner element in the genetic background. These results demonstrate that the mariner transposable element, which is small (1286 bp) and relatively homogeneous in size among different copies, is nevertheless capable of promoting the insertion of the large (13.2 kb) MlwB element. Because of the widespread phylogenetic distribution of mariner among insects, these results suggest that mariner might provide a wide hostrange transformation vector for insects. PMID:8394264

  8. Readability of medicinal package leaflets: a systematic review.

    PubMed

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2015-01-01

    OBJECTIVE To review studies on the readability of package leaflets of medicinal products for human use. METHODS We conducted a systematic literature review between 2008 and 2013 using the keywords "Readability and Package Leaflet" and "Readability and Package Insert" in the academic search engine Biblioteca do Conhecimento Online, comprising different bibliographic resources/databases. The preferred reporting items for systematic reviews and meta-analyses criteria were applied to prepare the draft of the report. Quantitative and qualitative original studies were included. Opinion or review studies not written in English, Portuguese, Italian, French, or Spanish were excluded. RESULTS We identified 202 studies, of which 180 were excluded and 22 were enrolled [two enrolling healthcare professionals, 10 enrolling other type of participants (including patients), three focused on adverse reactions, and 7 descriptive studies]. The package leaflets presented various readability problems, such as complex and difficult to understand texts, small font size, or few illustrations. The main methods to assess the readability of the package leaflet were usability tests or legibility formulae. Limitations with these methods included reduced number of participants; lack of readability formulas specifically validated for specific languages (e.g., Portuguese); and absence of an assessment on patients literacy, health knowledge, cognitive skills, levels of satisfaction, and opinions. CONCLUSIONS Overall, the package leaflets presented various readability problems. In this review, some methodological limitations were identified, including the participation of a limited number of patients and healthcare professionals, the absence of prior assessments of participant literacy, humor or sense of satisfaction, or the predominance of studies not based on role-plays about the use of medicines. These limitations should be avoided in future studies and be considered when interpreting the results.

  9. Humidity data for 9975 shipping packages with cane fiberboard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daugherty, W. L.

    The 9975 surveillance program is developing a technical basis to support extending the storage period of 9975 packages in K-Area Complex beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Direct measurements of humidity and fiberboard moisture content have been made on two test packages with cane fiberboard and varying internal heat levels from 0 up to 19W. With an internalmore » heat load, a temperature gradient in the fiberboard assembly leads to varying relative humidity in the air around the fiberboard. However, the absolute humidity tends to remain approximately constant throughout the package. The moisture content of fiberboard varies under the influence of several phenomena. Changes in local fiberboard temperature (from an internal heat load) can cause fiberboard moisture changes through absorption or evaporation. Fiberboard degradation at elevated temperature will produce water as a byproduct. And the moisture level within the package is constantly seeking equilibrium with that of the surrounding room air, which varies on a daily and seasonal basis. One indicator of the moisture condition within a 9975 package might be obtained by measuring the relative humidity in the upper air space, by inserting a humidity probe through a caplug hole. However, the data indicate that for the higher internal heat loads (15 and 19 watts), a large variation in internal moisture conditions produces little or no variation in the air space relative humidity. Therefore, this approach does not appear to be sensitive to fiberboard moisture variations at the higher heat loads which are of most interest to maintaining fiberboard integrity.« less

  10. APPARATUS AND TECHNIC FOR THE ADMINISTRATION OF INTRACAVITARY RADIOACTIVE ISOTOPES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michaud, N.J.; Liegner, L.M.

    1961-08-01

    The method of administration of radioactive isotopes in the treatment of pleural effusions and ascites associated with cancer will vary according to the therapeutic technic. A procedure with a suitable apparatus that utilizes an economical and sterile disposable package is described. The radioactive isotope, whether colloidal chromic phosphate (P/sup 32/) or colloidal gold (Au/sup 198/), can be obtained in th e exact amount prescribed. The entire apparatus is assembled within a few minutes under sterile conditions. Before the hypodermic needles are inserted into the radioactive isotope vial, the air is removed from the tubing by the flow of saline inmore » each segment. Each section is then clamped. The shielded radioactive isotope is then placed on a table or stand and the rubber seal of the vial is swabbed with alcohol or iodine. The inflow needle is inserted just through the rubber stopper and the outflow needle is inserted to the bottom of the vial. This procedure is carried out without removing the vial from the lead container. (auth)« less

  11. Strategies to improve electrode positioning and safety in cochlear implants.

    PubMed

    Rebscher, S J; Heilmann, M; Bruszewski, W; Talbot, N H; Snyder, R L; Merzenich, M M

    1999-03-01

    An injection-molded internal supporting rib has been produced to control the flexibility of silicone rubber encapsulated electrodes designed to electrically stimulate the auditory nerve in human subjects with severe to profound hearing loss. The rib molding dies, and molds for silicone rubber encapsulation of the electrode, were designed and machined using AutoCad and MasterCam software packages in a PC environment. After molding, the prototype plastic ribs were iteratively modified based on observations of the performance of the rib/silicone composite insert in a clear plastic model of the human scala tympani cavity. The rib-based electrodes were reliably inserted farther into these models, required less insertion force and were positioned closer to the target auditory neural elements than currently available cochlear implant electrodes. With further design improvements the injection-molded rib may also function to accurately support metal stimulating contacts and wire leads during assembly to significantly increase the manufacturing efficiency of these devices. This method to reliably control the mechanical properties of miniature implantable devices with multiple electrical leads may be valuable in other areas of biomedical device design.

  12. Safety analysis report for packaging (onsite) steel drum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCormick, W.A.

    This Safety Analysis Report for Packaging (SARP) provides the analyses and evaluations necessary to demonstrate that the steel drum packaging system meets the transportation safety requirements of HNF-PRO-154, Responsibilities and Procedures for all Hazardous Material Shipments, for an onsite packaging containing Type B quantities of solid and liquid radioactive materials. The basic component of the steel drum packaging system is the 208 L (55-gal) steel drum.

  13. 49 CFR 173.12 - Exceptions for shipment of waste materials.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (IBC) or a UN 11HH2 composite IBC, fitted with a polyethylene liner at least 6 mils (0.24 inches) thick... accordance paragraph (b) of this section or in single packagings authorized for the acid in Column (8B) of... this section or in single packagings authorized for the material in Column (8B) of the § 172.101...

  14. 49 CFR 173.12 - Exceptions for shipment of waste materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (IBC) or a UN 11HH2 composite IBC, fitted with a polyethylene liner at least 6 mils (0.24 inches) thick... accordance paragraph (b) of this section or in single packagings authorized for the acid in Column (8B) of... this section or in single packagings authorized for the material in Column (8B) of the § 172.101...

  15. Starch-based Antimicrobial Films Incorporated with Lauric Acid and Chitosan

    NASA Astrophysics Data System (ADS)

    Salleh, E.; Muhamad, I. I.

    2010-03-01

    Antimicrobial (AM) packaging is one of the most promising active packaging systems. Starch-based film is considered an economical material for antimicrobial packaging. This study aimed at the development of food packaging based on wheat starch incorporated with lauric acid and chitosan as antimicrobial agents. The purpose is to restrain or inhibit the growth of spoilage and/or pathogenic microorganisms that are contaminating foods. The antimicrobial effect was tested on B. substilis and E. coli. Inhibition of bacterial growth was examined using two methods, i.e. zone of inhibition test on solid media and liquid culture test (optical density measurements). The control and AM films (incorporated with chitosan and lauric acid) were produced by casting method. From the observations, AM films exhibited inhibitory zones. Interestingly, a wide clear zone on solid media was observed for B. substilis growth inhibition whereas inhibition for E. coli was not as effective as B. substilis. From the liquid culture test, the AM films clearly demonstrated a better inhibition against B. substilis than E. coli.

  16. Preparation and screening of an arrayed human genomic library generated with the P1 cloning system.

    PubMed Central

    Shepherd, N S; Pfrogner, B D; Coulby, J N; Ackerman, S L; Vaidyanathan, G; Sauer, R H; Balkenhol, T C; Sternberg, N

    1994-01-01

    We describe here the construction and initial characterization of a 3-fold coverage genomic library of the human haploid genome that was prepared using the bacteriophage P1 cloning system. The cloned DNA inserts were produced by size fractionation of a Sau3AI partial digest of high molecular weight genomic DNA isolated from primary cells of human foreskin fibroblasts. The inserts were cloned into the pAd10sacBII vector and packaged in vitro into P1 phage. These were used to generate recombinant bacterial clones, each of which was picked robotically from an agar plate into a well of a 96-well microtiter dish, grown overnight, and stored at -70 degrees C. The resulting library, designated DMPC-HFF#1 series A, consists of approximately 130,000-140,000 recombinant clones that were stored in 1500 microtiter dishes. To screen the library, clones were combined in a pooling strategy and specific loci were identified by PCR analysis. On average, the library contains two or three different clones for each locus screened. To date we have identified a total of 17 clones containing the hypoxanthine-guanine phosphoribosyltransferase, human serum albumin-human alpha-fetoprotein, p53, cyclooxygenase I, human apurinic endonuclease, beta-polymerase, and DNA ligase I genes. The cloned inserts average 80 kb in size and range from 70 to 95 kb, with one 49-kb insert and one 62-kb insert. Images PMID:8146166

  17. GE781: a Monte Carlo package for fixed target experiments

    NASA Astrophysics Data System (ADS)

    Davidenko, G.; Funk, M. A.; Kim, V.; Kuropatkin, N.; Kurshetsov, V.; Molchanov, V.; Rud, S.; Stutte, L.; Verebryusov, V.; Zukanovich Funchal, R.

    The Monte Carlo package for the fixed target experiment B781 at Fermilab, a third generation charmed baryon experiment, is described. This package is based on GEANT 3.21, ADAMO database and DAFT input/output routines.

  18. Efficient and simpler method to construct normalized cDNA libraries with improved representations of full-length cDNAs

    DOEpatents

    Soares, Marcelo Bento; Bonaldo, Maria de Fatima

    1998-01-01

    This invention provides a method to normalize a cDNA library comprising: (a) constructing a directionally cloned library containing cDNA inserts wherein the insert is capable of being amplified by polymerase chain reaction; (b) converting a double-stranded cDNA library into single-stranded DNA circles; (c) generating single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) by polymerase chain reaction with appropriate primers; (d) hybridizing the single-stranded DNA circles converted in step (b) with the complementary single-stranded nucleic acid molecules generated in step (c) to produce partial duplexes to an appropriate Cot; and (e) separating the unhybridized single-stranded DNA circles from the hybridized DNA circles, thereby generating a normalized cDNA library. This invention also provides a method to normalize a cDNA library wherein the generating of single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) is by excising cDNA inserts from the double-stranded cDNA library; purifying the cDNA inserts from cloning vectors; and digesting the cDNA inserts with an exonuclease. This invention further provides a method to construct a subtractive cDNA library following the steps described above. This invention further provides normalized and/or subtractive cDNA libraries generated by the above methods.

  19. Efficient and simpler method to construct normalized cDNA libraries with improved representations of full-length cDNAs

    DOEpatents

    Soares, M.B.; Fatima Bonaldo, M. de

    1998-12-08

    This invention provides a method to normalize a cDNA library comprising: (a) constructing a directionally cloned library containing cDNA inserts wherein the insert is capable of being amplified by polymerase chain reaction; (b) converting a double-stranded cDNA library into single-stranded DNA circles; (c) generating single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) by polymerase chain reaction with appropriate primers; (d) hybridizing the single-stranded DNA circles converted in step (b) with the complementary single-stranded nucleic acid molecules generated in step (c) to produce partial duplexes to an appropriate Cot; and (e) separating the unhybridized single-stranded DNA circles from the hybridized DNA circles, thereby generating a normalized cDNA library. This invention also provides a method to normalize a cDNA library wherein the generating of single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) is by excising cDNA inserts from the double-stranded cDNA library; purifying the cDNA inserts from cloning vectors; and digesting the cDNA inserts with an exonuclease. This invention further provides a method to construct a subtractive cDNA library following the steps described above. This invention further provides normalized and/or subtractive cDNA libraries generated by the above methods. 25 figs.

  20. The Ontology of Vaccine Adverse Events (OVAE) and its usage in representing and analyzing adverse events associated with US-licensed human vaccines.

    PubMed

    Marcos, Erica; Zhao, Bin; He, Yongqun

    2013-11-26

    Licensed human vaccines can induce various adverse events (AE) in vaccinated patients. Due to the involvement of the whole immune system and complex immunological reactions after vaccination, it is difficult to identify the relations among vaccines, adverse events, and human populations in different age groups. Many known vaccine adverse events (VAEs) have been recorded in the package inserts of US-licensed commercial vaccine products. To better represent and analyze VAEs, we developed the Ontology of Vaccine Adverse Events (OVAE) as an extension of the Ontology of Adverse Events (OAE) and the Vaccine Ontology (VO). Like OAE and VO, OVAE is aligned with the Basic Formal Ontology (BFO). The commercial vaccines and adverse events in OVAE are imported from VO and OAE, respectively. A new population term 'human vaccinee population' is generated and used to define VAE occurrence. An OVAE design pattern is developed to link vaccine, adverse event, vaccinee population, age range, and VAE occurrence. OVAE has been used to represent and classify the adverse events recorded in package insert documents of commercial vaccines licensed by the USA Food and Drug Administration (FDA). OVAE currently includes over 1,300 terms, including 87 distinct types of VAEs associated with 63 human vaccines licensed in the USA. For each vaccine, occurrence rates for every VAE in different age groups have been logically represented in OVAE. SPARQL scripts were developed to query and analyze the OVAE knowledge base data. To demonstrate the usage of OVAE, the top 10 vaccines accompanying with the highest numbers of VAEs and the top 10 VAEs most frequently observed among vaccines were identified and analyzed. Asserted and inferred ontology hierarchies classify VAEs in different levels of AE groups. Different VAE occurrences in different age groups were also analyzed. The ontology-based data representation and integration using the FDA-approved information from the vaccine package insert documents enables the identification of adverse events from vaccination in relation to predefined parts of the population (age groups) and certain groups of vaccines. The resulting ontology-based VAE knowledge base classifies vaccine-specific VAEs and supports better VAE understanding and future rational AE prevention and treatment.

  1. 78 FR 211 - Paper and Paper-Based Packaging Promotion, Research and Information Order; Referendum Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-02

    ... Service 7 CFR Part 1222 Paper and Paper-Based Packaging Promotion, Research and Information Order... [Document Number AMS-FV-11-0069 PR-B] RIN 0581-AD21 Paper and Paper-Based Packaging Promotion, Research and... referendum to determine whether issuance of a proposed Paper and Paper-Based Packaging Promotion, Research...

  2. 16 CFR 1700.4 - Effective date of standards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... a regulation establishing a child protection packaging standard shall indicate the standard's... 1700.4 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION POISON PREVENTION PACKAGING ACT OF 1970... shall apply. (b) Upon becoming effective, a child protection packaging standard shall apply only to...

  3. Detection of drugs in the urine of body-packers.

    PubMed

    Gherardi, R K; Baud, F J; Leporc, P; Marc, B; Dupeyron, J P; Diamant-Berger, O

    1988-05-14

    The presence of opiates and benzoylecgonine, the major metabolite of cocaine, in the urine was detected by means of enzyme immunoassay in a series of 120 smugglers who had either ingested or inserted into their rectum cocaine or heroin packaged for transportation. There was a striking relation between the presence of drugs in the urine and swallowing of drug-filled bundles (cocaine 49 of 50 cases, heroin 9 of 10). The proportion of positive results was also high in cases of rectal insertion (cocaine 2 of 2, heroin 35 of 58). In 30 cases of cocaine-packet ingestion, serial measurements showed that the accuracy of the test progressively decreased with respect to the detection of residual packets in the body. Drug detection in the urine of suspected body-packers seems to be a useful test, positive results justifying subsequent radiological investigations.

  4. Public antibodies to malaria antigens generated by two LAIR1 insertion modalities.

    PubMed

    Pieper, Kathrin; Tan, Joshua; Piccoli, Luca; Foglierini, Mathilde; Barbieri, Sonia; Chen, Yiwei; Silacci-Fregni, Chiara; Wolf, Tobias; Jarrossay, David; Anderle, Marica; Abdi, Abdirahman; Ndungu, Francis M; Doumbo, Ogobara K; Traore, Boubacar; Tran, Tuan M; Jongo, Said; Zenklusen, Isabelle; Crompton, Peter D; Daubenberger, Claudia; Bull, Peter C; Sallusto, Federica; Lanzavecchia, Antonio

    2017-08-31

    In two previously described donors, the extracellular domain of LAIR1, a collagen-binding inhibitory receptor encoded on chromosome 19 (ref. 1), was inserted between the V and DJ segments of an antibody. This insertion generated, through somatic mutations, broadly reactive antibodies against RIFINs, a type of variant antigen expressed on the surface of Plasmodium falciparum-infected erythrocytes. To investigate how frequently such antibodies are produced in response to malaria infection, we screened plasma from two large cohorts of individuals living in malaria-endemic regions. Here we report that 5-10% of malaria-exposed individuals, but none of the European blood donors tested, have high levels of LAIR1-containing antibodies that dominate the response to infected erythrocytes without conferring enhanced protection against febrile malaria. By analysing the antibody-producing B cell clones at the protein, cDNA and gDNA levels, we characterized additional LAIR1 insertions between the V and DJ segments and discovered a second insertion modality whereby the LAIR1 exon encoding the extracellular domain and flanking intronic sequences are inserted into the switch region. By exon shuffling, this mechanism leads to the production of bispecific antibodies in which the LAIR1 domain is precisely positioned at the elbow between the VH and CH1 domains. Additionally, in one donor the genomic DNA encoding the VH and CH1 domains was deleted, leading to the production of a camel-like LAIR1-containing antibody. Sequencing of the switch regions of memory B cells from European blood donors revealed frequent templated inserts originating from transcribed genes that, in rare cases, comprised exons with orientations and frames compatible with expression. These results reveal different modalities of LAIR1 insertion that lead to public and dominant antibodies against infected erythrocytes and suggest that insertion of templated DNA represents an additional mechanism of antibody diversification that can be selected in the immune response against pathogens and exploited for B cell engineering.

  5. The prevalence and some metabolic traits of Brochothrix thermosphacta in meat and meat products packaged in different ways.

    PubMed

    Nowak, Agnieszka; Rygala, Anna; Oltuszak-Walczak, Elzbieta; Walczak, Piotr

    2012-04-01

    The effect of Brochothrix thermosphacta on the quality of meat and meat products is of vital importance in connection with Regulation EC/178/2002 extending the definition of unsafe foodstuffs to encompass all those which are unfit for human consumption. This study aimed to determine the prevalence of B. thermosphacta in meat and meat products packaged under different conditions and to estimate the effect of B. thermosphacta strains on product quality based on their protein and lipid degradation activity. B. thermosphacta was absent in only two of 132 samples. All other samples were contaminated with this bacterium (10(1) to 10(9) cfu g(-1) meat and 10(2) to 10(8) cfu g(-1) meat product). In products stored under high-oxygen atmosphere Brochothrix cells accounted for almost 100% total mesophilic count (TMC) and below 50% TMC in oxygen-free atmosphere. While the tested B. thermosphacta strains did not show any proteolytic activity, most of them displayed lipolytic activity at 25 °C and some even at 4 °C. B. thermosphacta is commonly present in meat and meat products packaged in different ways. This bacterium can display lipolytic activity also at refrigeration temperature. Its over-proliferation can be inhibited through vacuum packaging or packaging under a modified atmosphere with reduced oxygen content. Copyright © 2011 Society of Chemical Industry.

  6. Type B drum packages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCoy, J.C.

    1994-08-01

    The Type B drum packages (TBD) are conceptualized as a family of containers in which a single 208 L or 114 L (55 gal or 30 gal) drum containing Type B quantities of radioactive material (RAM) can be packaged for shipment. The TBD containers are being developed to fill a void in the packaging and transportation capabilities of the U.S. Department of Energy as no container packaging single drums of Type B RAM exists offering double containment. Several multiple-drum containers currently exist, as well as a number of shielded casks, but the size and weight of these containers present manymore » operational challenges for single-drum shipments. As an alternative, the TBD containers will offer up to three shielded versions (light, medium, and heavy) and one unshielded version, each offering single or optional double containment for a single drum. To reduce operational complexity, all versions will share similar design and operational features where possible. The primary users of the TBD containers are envisioned to be any organization desiring to ship single drums of Type B RAM, such as laboratories, waste retrieval activities, emergency response teams, etc. Currently, the TBD conceptual design is being developed with the final design and analysis to be completed in 1995 to 1996. Testing and certification of the unshielded version are planned to be completed in 1996 to 1997 with production to begin in 1997 to 1998.« less

  7. Construction and production of oncotropic vectors, derived from MVM(p), that share reduced sequence homology with helper plasmids.

    PubMed

    Clément, Nathalie; Velu, Thierry; Brandenburger, Annick

    2002-09-01

    The production of currently available vectors derived from autonomous parvoviruses requires the expression of capsid proteins in trans, from helper sequences. Cotransfection of a helper plasmid always generates significant amounts of replication-competent virus (RCV) that can be reduced by the integration of helper sequences into a packaging cell line. Although stocks of minute virus of mice (MVM)-based vectors with no detectable RCV could be produced by transfection into packaging cells; the latter appear after one or two rounds of replication, precluding further amplification of the vector stock. Indeed, once RCVs become detectable, they are efficiently amplified and rapidly take over the culture. Theoretically RCV-free vector stocks could be produced if all homology between vector and helper DNA is eliminated, thus preventing homologous recombination. We constructed new vectors based on the structure of spontaneously occurring defective particles of MVM. Based on published observations related to the size of vectors and the sequence of the viral origin of replication, these vectors were modified by the insertion of foreign DNA sequences downstream of the transgene and by the introduction of a consensus NS-1 nick site near the origin of replication to optimize their production. In one of the vectors the inserted fragment of mouse genomic DNA had a synergistic effect with the modified origin of replication in increasing vector production.

  8. Evaluation of package inserts of Ayurveda drug formulations from Mumbai city.

    PubMed

    Shirolkar, Sudatta; Tripathi, Raakhi K; Potey, Anirudha V

    2015-01-01

    Package insert (PI) is a vital document accompanying a prescribed medication to provide information to the prescriber and end-user at a glance. Studies regarding PIs of Ayurvedic medicines in accordance with standard guidelines are lacking. Present study was undertaken to evaluate PI of Ayurveda drugs. PIs of Ayurveda drugs were obtained from five randomly selected Ayurveda medical shops located in three main zones of Mumbai. From each medical shop, a range of 15-20 PI was planned to be collected for different formulations. It was decided to collect a minimum fifty PIs/group for equitable distribution of various formulations in period of January-June2013. Checklist was prepared, and content validity was achieved. Final validated checklist contained a total of 13 items, and the presence or absence of information pertaining to these items on the PI was evaluated. Any other additional information present on PI was also noted. Each item was analyzed and expressed as percentages. The information on 258 PIs included: Name of ingredients (67%), quantity of ingredients (47.27%), route of administration (86.8%), dosage form (86.8%), indications (18%), dose (18%), contraindications (18%), side effects (9%), shelf life (5.81%), storage conditions (11%), and manufacturers name with contact details (34%). PIs accompanying Ayurveda medicinal products in India are deficient in information required to be furnished by them.

  9. Magnetic thermometry in the aseptic processing of foods containing particulates (abstract)

    NASA Astrophysics Data System (ADS)

    Ghiron, Kenneth; Litchfield, Bruce

    1997-04-01

    Aseptic processing of foods has many advantages over canning, including higher efficiency, lighter packaging, better taste, and higher nutritional value. Aseptic processing is different from canning where the food and container are sterilized together. Instead, a thin stream of food is heated and the packaging is independently sterilized before the food is placed in the package. However, no aseptic processes have been successfully filed with the FDA for foods containing sizable solid particles because of uncertainties in the thermal sterilization of the particles (e.g., soup). We have demonstrated that by inserting small paramagnetic particles in the interior of the simulated and real food particles, the local temperature can be measured. With this information, any questions about the adequate sterilization of the particles can be resolved. The measurements were done by directing the food stream through a magnetic field and sensing the voltages induced in a pickup coil by the motion of the magnetized particles. Details of the equipment design and data analysis will be discussed along with an introduction to the aseptic processing of foods.

  10. 49 CFR 172.310 - Class 7 (radioactive) materials.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... packaging, in letters at least 13 mm (0.5 in) high, with the words “TYPE IP-1,” “TYPE IP-2,” “TYPE IP-3,” “TYPE A,” “TYPE B(U)” or “TYPE B(M),” as appropriate. A package which does not conform to Type IP-1, Type IP-2, Type IP-3, Type A, Type B(U) or Type B(M) requirements may not be so marked. (c) Each...

  11. 49 CFR 172.310 - Class 7 (radioactive) materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... packaging, in letters at least 13 mm (0.5 in) high, with the words “TYPE IP-1,” “TYPE IP-2,” “TYPE IP-3,” “TYPE A,” “TYPE B(U)” or “TYPE B(M),” as appropriate. A package which does not conform to Type IP-1, Type IP-2, Type IP-3, Type A, Type B(U) or Type B(M) requirements may not be so marked. (c) Each...

  12. 9978 AND 9975 TYPE B PACKAGING INTERNAL DATA COLLECTION FEASIBILITY TESTING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fogle, R.

    The objective of this report is to document the findings from a series of proof-of-concept tests performed by Savannah River National Laboratory (SRNL) R and D Engineering, for the DOE Packaging Certification Program to determine if a viable radio link could be established from within the stainless steel confines of several drum-style DOE certified Type B radioactive materials packagings. Two in-hand, off-the-shelf radio systems were tested. The first system was a Wi-Fi Librestream Onsight{trademark} camera with a Fortress ES820 Access Point and the second was the On-Ramp Wireless Ultra-Link Processing{trademark} (ULP) radio system. These radio systems were tested within themore » Model 9975 and 9978 Type B packagings at the SRNL. This report documents the test methods and results. A path forward will also be recommended.« less

  13. 2 CFR 200.512 - Report submission.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the reporting package do not include protected personally identifiable information. (b) Data... packages and the data collection form. All Federal agencies, pass-through entities and others interested in a reporting package and data collection form must obtain it by accessing the FAC. (1) The auditee...

  14. Metabolism and gene polymorphisms of the folate pathway in Brazilian women with history of recurrent abortion.

    PubMed

    Boas, Wendell Vilas; Gonçalves, Rozana Oliveira; Costa, Olívia Lúcia Nunes; Goncalves, Marilda Souza

    2015-02-01

    To investigate the association between polymorphisms in genes that encode enzymes involved in folate- and vitamin B12-dependent homocysteine metabolism and recurrent spontaneous abortion (RSA). We investigated the C677T and A1298C polymorphisms of the methylenetetrahydrofalate reductase gene (MTHFR), the A2756G polymorphism of the methionine synthase gene (MS) and the 844ins68 insertion of the cystathionine beta synthetase gene (CBS). The PCR technique followed by RFLP was used to assess the polymorphisms; the serum levels of homocysteine, vitamin B12 and folate were investigated by chemiluminescence. The EPI Info Software version 6.04 was used for statistical analysis. Parametric variables were compared by Student's t-test and nonparametric variables by the Wilcoxon rank sum test. The frequencies of gene polymorphisms in 89 women with a history of idiopathic recurrent miscarriage and 150 controls were 19.1 and 19.6% for the C677T, insertion, 20.8 and 26% for the A1298C insertion, 14.2 and 21.9% for the A2756G insertion, and 16.4 and 18% for the 844ins68 insertion, respectively. There were no significant differences between case and control groups in any of the gene polymorphisms investigated. However, the frequency of the 844ins68 insertion in the CBS gene was higher among women with a history of loss during the third trimester of pregnancy (p=0.003). Serum homocysteine, vitamin B12 and folate levels id not differ between the polymorphisms studied in the case and control groups. However, linear regression analysis showed a dependence of serum folate levels on the maintenance of tHcy levels. The investigated gene polymorphisms and serum homocysteine, vitamin B12 and folate levels were not associated with idiopathic recurrent miscarriage in the present study. Further investigations are needed in order to confirm the role of the CBS 844ins68 insertion in recurrent miscarriage.

  15. Is antibiotic prophylaxis mandatory after the insertion of levonorgestrel-releasing intrauterine systemin order to decrease the risk of pelvic inflammatory disease?

    PubMed

    Munteanu, O; Radulescu, L; Bodean, O; Cirstoiu, C; Secara, D; Cirstoiu, M

    2013-01-01

    This study was undertaken in order to determine if antibiotic prophylaxis is mandatory, after the insertion of levonorgestrel-releasing intrauterine system in order to decrease the risk of pelvic inflammatory disease. We prospectively evaluated 44 patients, admitted in the Bucharest Emergency Hospital between the 1ⁱ of February 2012 and the 1ⁱ of October 2012, in whom the levonorgestrel-releasing intrauterine system was inserted. The patients enrolled were divided into two groups. In group A, a number of 22 patients, received, after the insertion of levonorgestrel-releasing intrauterine system, 875mg Amoxicillin Trihydrate + 125 mg Potassium Clavulanate, a dose every 12 hours for 5 days. Group B was represented by the other 22 patients who did not receive antibiotic prophylaxis. All patients were reevaluated at 4 and 12 weeks after the insertion of levonorgestrel-releasing intrauterine system. During the first 4 weeks after the insertion of levonorgestrel-releasing intrauterine system only two patients, one from group A and one from group B were diagnosed with pelvic inflammatory disease. At a second follow up visit - 12 weeks after the insertion of levonorgestrel-releasing intrauterine system, no other patient was diagnosed with pelvic inflammatory disease. Antibiotic prophylaxis is not mandatory, after the insertion of levonorgestrel-releasing intrauterine system in order to decrease the risk of pelvic inflammatory disease.

  16. Determining Permissible Oxygen and Water Vapor Transmission Rate for Non-Retort Military Ration Packaging

    DTIC Science & Technology

    2011-11-01

    OXYGEN AND WATER VAPOR TRANSMISSION RATE FOR NON- RETORT MILITARY RATION PACKAGING by Danielle Froio Alan Wright Nicole Favreau and Sarah...ANSI Std. Z39.18 RETORT STORAGE SHELF LIFE RETORT POUCHES SENSORY ANALYSIS OXYGEN CRACKERS PACKAGING SENSORY... Packaging for MRE. (a) MRE Retort Pouch Quad-Laminate Structure; (b) MRE Non- retort Pouch Tri-Laminate Structure

  17. 49 CFR 175.703 - Other special requirements for the acceptance and carriage of packages containing Class 7 materials.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... transport, by air— (1) Vented Type B(M) packages, packages which require external cooling by an ancillary cooling system or packages subject to operational controls during transport; or (2) Liquid pyrophoric... transport index in excess of the limits specified in § 173.441(a) of this subchapter may not be transported...

  18. 21 CFR 501.3 - Identity labeling of animal food in package form.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Identity labeling of animal food in package form... § 501.3 Identity labeling of animal food in package form. (a) The principal display panel of a food in package form shall bear as one of its principal features a statement of the identity of the commodity. (b...

  19. 21 CFR 501.3 - Identity labeling of animal food in package form.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Identity labeling of animal food in package form... § 501.3 Identity labeling of animal food in package form. (a) The principal display panel of a food in package form shall bear as one of its principal features a statement of the identity of the commodity. (b...

  20. 21 CFR 501.3 - Identity labeling of animal food in package form.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Identity labeling of animal food in package form... § 501.3 Identity labeling of animal food in package form. (a) The principal display panel of a food in package form shall bear as one of its principal features a statement of the identity of the commodity. (b...

  1. GEMINI-TITAN (GT)-XI - MISC. EXPERIMENTS - MSC

    NASA Image and Video Library

    1966-03-22

    S66-05515 (2 June 1966) --- Gemini-11 Experiment S-9 Nuclear Emulsion. This experiment will be used to study the cosmic radiation incident on Earth's atmosphere, to obtain detailed chemical composition of the heavy primary nuclei and to search for rare particles. Equipment is a rectangular package eight and a half by six by three inches weighing 15 pounds and including the nuclear emulsion film stack, motor to advance the emulsion and a timer to regulate the motor. The package is mounted atop the spacecraft retro adapter section prior to launch, is activated at insertion, and is retrieved by the EVA pilot. The experiment is conducted with the spacecraft in plus or minus 15 degrees of Earth's average magnetic field vector. Sponsors are NASA's Office of Space Science and Applications and the U.S. Naval Research Laboratories. Photo credit: NASA

  2. Autonomous microexplosives subsurface tracing system final report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engler, Bruce Phillip; Nogan, John; Melof, Brian Matthew

    The objective of the autonomous micro-explosive subsurface tracing system is to image the location and geometry of hydraulically induced fractures in subsurface petroleum reservoirs. This system is based on the insertion of a swarm of autonomous micro-explosive packages during the fracturing process, with subsequent triggering of the energetic material to create an array of micro-seismic sources that can be detected and analyzed using existing seismic receiver arrays and analysis software. The project included investigations of energetic mixtures, triggering systems, package size and shape, and seismic output. Given the current absence of any technology capable of such high resolution mapping ofmore » subsurface structures, this technology has the potential for major impact on petroleum industry, which spends approximately $1 billion dollar per year on hydraulic fracturing operations in the United States alone.« less

  3. Quality of Meat (Longissimus dorsi) from Male Fallow Deer (Dama dama) Packaged and Stored under Vacuum and Modified Atmosphere Conditions

    PubMed Central

    Piaskowska, N.; Daszkiewicz, T.; Kubiak, D.; Zapotoczny, P.

    2016-01-01

    This study evaluated the effect of vacuum and modified atmosphere (40% CO2+60% N2, MA) packaging on the chemical composition, physicochemical properties and sensory attributes of chill-stored meat from 10 fallow deer (Dama dama) bucks at 17 to 18 months of age. The animals were hunter-harvested in the forests of north-eastern Poland. During carcass dressing (48 to 54 h post mortem), both musculus longissimus muscles were cut out. Each muscle was divided into seven sections which were allocated to three groups: 0, A, and B. Samples 0 were immediately subjected to laboratory analyses. Samples A were vacuum-packaged, and samples B were packaged in MA. Packaged samples were stored for 7, 14, and 21 days at 2°C. The results of the present study showed that the evaluated packaging systems had no significant effect on the quality of fallow deer meat during chilled storage. However, vacuum-packaged meat samples were characterised by greater drip loss. Vacuum and MA packaging contributed to preserving the desired physicochemical properties and sensory attributes of meat during 21 days of storage. Regardless of the packaging method used, undesirable changes in the colour, water-holding capacity and juiciness of meat, accompanied by tenderness improvement, were observed during chilled storage. PMID:27165026

  4. RH Packaging Program Guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Washington TRU Solutions LLC

    The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package (also known as the "RH-TRU 72-B cask") and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: "...each package must be prepared for shipmentmore » and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." It further states: "...each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M&O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8, "Deliberate Misconduct." Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.In accordance with 10 CFR Part 71, "Packaging and Transportation of Radioactive Material," certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, "Reporting of Defects and Noncompliance," regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are conducted. This document details the instructions to be followed to operate, maintain, and test the RH-TRU 72-B packaging. This Program Guidance standardizes instructions for all users. Users shall follow these instructions or equivalent approved instructions. Following these instructions assures that operations meet the requirements of the SARP.« less

  5. Theoretical investigation on the potential energy surface for the reactions of B, Al and Ga with NO

    NASA Astrophysics Data System (ADS)

    Zhang, Luning; Zhou, Mingfei

    2000-06-01

    The structures, binding energies and vibrational frequencies of various MNO structural isomers (M=B, Al and Ga) in their ground triplet states have been determined using the density functional (B3LYP, BP86 and B3PW91) and MP2 methods. The potential energy surfaces of the M+NO reactions have been developed at the B3LYP/6-311+G(d) level of theory, and transition states on the isomerization potential energy surfaces have been characterized. Our calculation results show that four BNO isomers, namely, nitrosyl BNO, isonitrosyl BON, side-bonded B- η2-NO and the inserted NBO molecules are stationary points, while for Al and Ga, only the MNO (nitrosyl), MON (isonitrosyl) and the OMN (insertion) molecules are local minimum. The B+NO reaction products are more strongly bonded compared to the Al and Ga+NO systems due to strong covalent bonding. The interactions of B, Al and Ga atoms with NO to generate nitrosyl and isonitrosyl addition molecules are barrierless, but subsequent isomerization reactions to form the side-bonded molecules and the inserted products require activation energy.

  6. Effect of skin disinfection with octenidine dihydrochloride on insertion site colonization of intravascular catheters.

    PubMed

    Dettenkofer, M; Jonas, D; Wiechmann, C; Rossner, R; Frank, U; Zentner, J; Daschner, F D

    2002-10-01

    We investigated the efficacy of two commercially available, alcohol-based antiseptic solutions in decontaminating the insertion site of central lines. One solution contained the bispyridine octenidine dihydrochloride. Inpatients receiving either a central venous catheter (CVC) or a peripherally inserted central catheter (PICC) were alternately assigned to different skin disinfection regimens at the insertion site: (A) 0.1% octendine dihydrochloride with 30% 1-propanol and 45% 2-propanol, (B) 74% ethanol with 10% 2-propanol. Quantitative skin cultures were obtained from the insertion site at predetermined intervals. A total of 60 patients received 12 CVCs and 47 PICCs (no significant difference with respect to gender, age and catheter type). In total, 90 cultures were assessed in each group. The median colony-forming unit (cfu) counts per 24 cm(2) (group A vs B) were 2,270 vs 2,950 before, 20 vs 40 following and 860 vs 1,210 24 h after catheter insertion, respectively. A statistically significant difference in the efficacy of skin decontamination was seen between groups in culture set (3) and in the difference between culture sets (2) and (3) (Wilcoxon rank sum test). Octenidine/propanol appears to be more effective than alcohol (ethanol/propanol) alone in reducing microflora of the skin at the PICC/CVC insertion site over a 24-h period.

  7. 38 CFR 41.320 - Report submission.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... is limited to the data elements prescribed by OMB. (c) Reporting package. The reporting package shall... not submitted the required data collection forms and reporting packages. (i) Clearinghouse address...) General. The audit shall be completed and the data collection form described in paragraph (b) of this...

  8. 38 CFR 41.320 - Report submission.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... is limited to the data elements prescribed by OMB. (c) Reporting package. The reporting package shall... not submitted the required data collection forms and reporting packages. (i) Clearinghouse address...) General. The audit shall be completed and the data collection form described in paragraph (b) of this...

  9. 38 CFR 41.320 - Report submission.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... is limited to the data elements prescribed by OMB. (c) Reporting package. The reporting package shall... not submitted the required data collection forms and reporting packages. (i) Clearinghouse address...) General. The audit shall be completed and the data collection form described in paragraph (b) of this...

  10. 38 CFR 41.320 - Report submission.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... is limited to the data elements prescribed by OMB. (c) Reporting package. The reporting package shall... not submitted the required data collection forms and reporting packages. (i) Clearinghouse address...) General. The audit shall be completed and the data collection form described in paragraph (b) of this...

  11. 38 CFR 41.320 - Report submission.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... is limited to the data elements prescribed by OMB. (c) Reporting package. The reporting package shall... not submitted the required data collection forms and reporting packages. (i) Clearinghouse address...) General. The audit shall be completed and the data collection form described in paragraph (b) of this...

  12. [Accumulation of the bvg- Bordetella pertussis a virulent mutants in the process of experimental whooping cough in mice].

    PubMed

    Medkova, A Iu; Siniashina, L N; Rumiantseva, Iu P; Voronina, O L; Kunda, M S; Karataev, G I

    2013-01-01

    The duration of the persistence and dynamics of accumulation of insertion bvg- Bordetella pertussis mutants were studied in lungs of laboratory mice after intranasal and intravenous challenge by virulent bacteria of the causative agent of whooping cough. The capability of the virulent B. pertussis bacteria to long-term persistence in the body of mice was tested. Using the real-time PCR approximately hundred genome equivalents of the B. pertussis DNA were detected in lungs of mice in two months after infection regardless of the way of challenge. Using the bacterial test bacteria were identified during only four weeks after challenge. Bvg- B. pertussis avirulent mutants were accumulated for the infection time. The percentage of the avirulent bacteria in the B. pertussis population reached 50% in 7-9 weeks after challenge. The obtained results show that the laboratory mice can be used for study of the B. pertussis insertion mutant formation dynamics in vivo and confirm the hypothesis about insertional bvg- B. pertussis virulent mutants accumulation during development of pertussis infection in human.

  13. Practical Thermal Evaluation Methods For HAC Fire Analysis In Type B Radiaoactive Material (RAM) Packages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abramczyk, Glenn; Hensel, Stephen J; Gupta, Narendra K.

    Title 10 of the United States Code of Federal Regulations Part 71 for the Nuclear Regulatory Commission (10 CFR Part 71.73) requires that Type B radioactive material (RAM) packages satisfy certain Hypothetical Accident Conditions (HAC) thermal design requirements to ensure package safety during accidental fire conditions. Compliance with thermal design requirements can be met by prototype tests, analyses only or a combination of tests and analyses. Normally, it is impractical to meet all the HAC using tests only and the analytical methods are too complex due to the multi-physics non-linear nature of the fire event. Therefore, a combination of testsmore » and thermal analyses methods using commercial heat transfer software are used to meet the necessary design requirements. The authors, along with his other colleagues at Savannah River National Laboratory in Aiken, SC, USA, have successfully used this 'tests and analyses' approach in the design and certification of several United States' DOE/NNSA certified packages, e.g. 9975, 9977, 9978, 9979, H1700, and Bulk Tritium Shipping Package (BTSP). This paper will describe these methods and it is hoped that the RAM Type B package designers and analysts can use them for their applications.« less

  14. Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy.

    PubMed

    Austein, Friederike; Riedel, Christian; Kerby, Tina; Meyne, Johannes; Binder, Andreas; Lindner, Thomas; Huhndorf, Monika; Wodarg, Fritz; Jansen, Olav

    2016-09-01

    Computed tomographic perfusion represents an interesting physiological imaging modality to select patients for reperfusion therapy in acute ischemic stroke. The purpose of our study was to determine the accuracy of different commercial perfusion CT software packages (Philips (A), Siemens (B), and RAPID (C)) to predict the final infarct volume (FIV) after mechanical thrombectomy. Single-institutional computed tomographic perfusion data from 147 mechanically recanalized acute ischemic stroke patients were postprocessed. Ischemic core and FIV were compared about thrombolysis in cerebral infarction (TICI) score and time interval to reperfusion. FIV was measured at follow-up imaging between days 1 and 8 after stroke. In 118 successfully recanalized patients (TICI 2b/3), a moderately to strongly positive correlation was observed between ischemic core and FIV. The highest accuracy and best correlation are shown in early and fully recanalized patients (Pearson r for A=0.42, B=0.64, and C=0.83; P<0.001). Bland-Altman plots and boxplots demonstrate smaller ranges in package C than in A and B. Significant differences were found between the packages about over- and underestimation of the ischemic core. Package A, compared with B and C, estimated more than twice as many patients with a malignant stroke profile (P<0.001). Package C best predicted hypoperfusion volume in nonsuccessfully recanalized patients. Our study demonstrates best accuracy and approximation between the results of a fully automated software (RAPID) and FIV, especially in early and fully recanalized patients. Furthermore, this software package overestimated the FIV to a significantly lower degree and estimated a malignant mismatch profile less often than other software. © 2016 American Heart Association, Inc.

  15. The Product of the Herpes Simplex Virus Type 1 UL25 Gene Is Required for Encapsidation but Not for Cleavage of Replicated Viral DNA

    PubMed Central

    McNab, Alistair R.; Desai, Prashant; Person, Stan; Roof, Lori L.; Thomsen, Darrell R.; Newcomb, William W.; Brown, Jay C.; Homa, Fred L.

    1998-01-01

    The herpes simplex virus type 1 (HSV-1) UL25 gene contains a 580-amino-acid open reading frame that codes for an essential protein. Previous studies have shown that the UL25 gene product is a virion component (M. A. Ali et al., Virology 216:278–283, 1996) involved in virus penetration and capsid assembly (C. Addison et al., Virology 138:246–259, 1984). In this study, we describe the isolation of a UL25 mutant (KUL25NS) that was constructed by insertion of an in-frame stop codon in the UL25 open reading frame and propagated on a complementing cell line. Although the mutant was capable of synthesis of viral DNA, it did not form plaques or produce infectious virus in noncomplementing cells. Antibodies specific for the UL25 protein were used to demonstrate that KUL25NS-infected Vero cells did not express the UL25 protein. Western immunoblotting showed that the UL25 protein was associated with purified, wild-type HSV A, B, and C capsids. Transmission electron microscopy indicated that the nucleus of Vero cells infected with KUL25NS contained large numbers of both A and B capsids but no C capsids. Analysis of infected cells by sucrose gradient sedimentation analysis confirmed that the ratio of A to B capsids was elevated in KUL25NS-infected Vero cells. Following restriction enzyme digestion, specific terminal fragments were observed in DNA isolated from KUL25NS-infected Vero cells, indicating that the UL25 gene was not required for cleavage of replicated viral DNA. The latter result was confirmed by pulsed-field gel electrophoresis (PFGE), which showed the presence of genome-size viral DNA in KUL25NS-infected Vero cells. DNase I treatment prior to PFGE demonstrated that monomeric HSV DNA was not packaged in the absence of the UL25 protein. Our results indicate that the product of the UL25 gene is required for packaging but not cleavage of replicated viral DNA. PMID:9445000

  16. Topology of the membrane protein LamB by epitope tagging and a comparison with the X-ray model.

    PubMed

    Newton, S M; Klebba, P E; Michel, V; Hofnung, M; Charbit, A

    1996-06-01

    We previously developed a genetic approach to study, with a single antibody, the topology of the outer membrane protein LamB, an Escherichia coli porin with specificity towards maltodextrins and a receptor for bacteriophage lambda. Our initial procedure consisted of inserting at random the same reporter epitope (the C3 neutralization epitope from poliovirus) into permissive sites of LamB (i.e., sites which tolerate insertions without deleterious effects on the protein activities or the cell). A specific monoclonal antibody was then used to examine the position of the inserted epitope with respect to the protein and the membrane. In the present work, we set up a site-directed procedure to insert the C3 epitope at new sites in order to distinguish between two-dimensional folding models. This allowed us to identify two new surface loops of LamB and to predict another periplasmic exposed region. The results obtained by random and directed epitope tagging are analyzed in light of the recently published X-ray structure of the LamB protein. Study of 23 hybrid LamB-C3 proteins led to the direct identification of five of the nine external loops (L4, L5, L6, L7, and L9) and led to the prediction of four periplasmic loops (I1, I4, I5, and I8) of LamB. Nine of the hybrid proteins did not lead to topological conclusions, and none led to the wrong predictions or conclusions. The comparison indicates that parts of models based on secondary structure predictions alone are not reliable and points to the importance of experimental data in the establishment of outer membrane protein topological models. The advantages and limitations of genetic foreign epitope insertion for the study of integral membrane proteins are discussed.

  17. Corneal epithelial cell biocompatibility to silicone hydrogel and conventional hydrogel contact lens packaging solutions

    PubMed Central

    Tanti, N.C.; Jones, L.; Sheardown, H.

    2010-01-01

    Purpose Although all contact lenses (CLs) are applied initially to the eye directly from a packaging solution, little is known about the effects of these solutions on human corneal epithelial cells (HCECs). Due to the porous nature of CL materials, they have the potential to sorb components of the packaging solution during storage, which could then be subsequently released upon insertion of the CL on the eye. The purpose of this study was to investigate the effect of various packaging solutions on HCECs, using an in vitro model. Methods An in vitro assay was developed whereby various silicone hydrogels and conventional, poly-2-hydroxyethylmethacrylate  (polyHEMA)-based lens materials were removed directly from their packaging and then incubated for up to 24 h with HCECs. The effect of the retained and released packaging solution components on HCECs was assessed by measuring cell viability, adhesion phenotype, and apoptosis. Results Incubation of HCECs with CLs stored in borate-buffered packaging solutions resulted in a significant reduction in cell viability. Adherent cells incubated with these CLs also exhibited reduced levels of β1 and α3 integrin. Soaking borate-buffered packaged CLs in PBS before cell incubation resolved viability and integrin expression in all cases, with the exception of galyfilcon A and balafilcon A, from which a 20% reduction in cell viability was still observed. In comparison, CLs stored in phosphate-buffered packaging solutions had cellular viability and expression of integrins similar to control cells (cells incubated in the absence of a lens). When incubated with cells at a 10% concentration in serum-free medium, borate-buffered packaging solutions and borate-containing saline (Unisol 4) significantly reduced cell viability and integrin expression. Neither caspase activation nor annexin V binding was observed on cells following exposure to borate buffer solution. However, a significant decrease in reactive oxygen species was observed at 24 h. These latter results suggest that in vitro exposure to low concentration of borate/boric acid results in cell dysfunction, leading to necrosis rather than apoptosis. Conclusions Borate-buffered packaging solutions were shown to adversely affect the viability and integrin expression of HCECs in vitro. When used in ophthalmic packaging solutions, the antimicrobial properties of borate buffer may be outweighed by its relatively cytotoxic effects on cells. PMID:20169012

  18. Corneal epithelial cell biocompatibility to silicone hydrogel and conventional hydrogel contact lens packaging solutions.

    PubMed

    Gorbet, M B; Tanti, N C; Jones, L; Sheardown, H

    2010-02-19

    Although all contact lenses (CLs) are applied initially to the eye directly from a packaging solution, little is known about the effects of these solutions on human corneal epithelial cells (HCECs). Due to the porous nature of CL materials, they have the potential to sorb components of the packaging solution during storage, which could then be subsequently released upon insertion of the CL on the eye. The purpose of this study was to investigate the effect of various packaging solutions on HCECs, using an in vitro model. An in vitro assay was developed whereby various silicone hydrogels and conventional, poly-2-hydroxyethylmethacrylate (polyHEMA)-based lens materials were removed directly from their packaging and then incubated for up to 24 h with HCECs. The effect of the retained and released packaging solution components on HCECs was assessed by measuring cell viability, adhesion phenotype, and apoptosis. Incubation of HCECs with CLs stored in borate-buffered packaging solutions resulted in a significant reduction in cell viability. Adherent cells incubated with these CLs also exhibited reduced levels of beta(1) and alpha(3) integrin. Soaking borate-buffered packaged CLs in PBS before cell incubation resolved viability and integrin expression in all cases, with the exception of galyfilcon A and balafilcon A, from which a 20% reduction in cell viability was still observed. In comparison, CLs stored in phosphate-buffered packaging solutions had cellular viability and expression of integrins similar to control cells (cells incubated in the absence of a lens). When incubated with cells at a 10% concentration in serum-free medium, borate-buffered packaging solutions and borate-containing saline (Unisol 4) significantly reduced cell viability and integrin expression. Neither caspase activation nor annexin V binding was observed on cells following exposure to borate buffer solution. However, a significant decrease in reactive oxygen species was observed at 24 h. These latter results suggest that in vitro exposure to low concentration of borate/boric acid results in cell dysfunction, leading to necrosis rather than apoptosis. Borate-buffered packaging solutions were shown to adversely affect the viability and integrin expression of HCECs in vitro. When used in ophthalmic packaging solutions, the antimicrobial properties of borate buffer may be outweighed by its relatively cytotoxic effects on cells.

  19. Image Steganography In Securing Sound File Using Arithmetic Coding Algorithm, Triple Data Encryption Standard (3DES) and Modified Least Significant Bit (MLSB)

    NASA Astrophysics Data System (ADS)

    Nasution, A. B.; Efendi, S.; Suwilo, S.

    2018-04-01

    The amount of data inserted in the form of audio samples that use 8 bits with LSB algorithm, affect the value of PSNR which resulted in changes in image quality of the insertion (fidelity). So in this research will be inserted audio samples using 5 bits with MLSB algorithm to reduce the number of data insertion where previously the audio sample will be compressed with Arithmetic Coding algorithm to reduce file size. In this research will also be encryption using Triple DES algorithm to better secure audio samples. The result of this research is the value of PSNR more than 50dB so it can be concluded that the image quality is still good because the value of PSNR has exceeded 40dB.

  20. Packaging Concerns and Techniques for Large Devices: Challenges for Complex Electronics

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2010-01-01

    NASA is going to have to accept the use of non-hermetic packages for complex devices. There are a large number of packaging options available. Space application subjects the packages to stresses that they were probably not designed for (vacuum for instance). NASA has to find a way of having assurance in the integrity of the packages. There are manufacturers interested in qualifying non-hermetic packages to MIL-PRF-38535 Class V. Government space users are agreed that Class V should be for hermetic packages only. NASA is working on a new Class for non-hermetic packages for M38535 Appendix B, "Class Y". Testing for package integrity will be required but can be package specific as described by a Package Integrity Test Plan. The plan is developed by the manufacturer and approved by DSCC and government space.

  1. 76 FR 27958 - Airworthiness Directives; Bell Helicopter Textron Canada (Bell) Model 206A, 206B, and 206B3...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    ... hover, with litter doorpost removed is prohibited.'' This revision may be made by pen and ink changes... revision may be made by pen and ink changes, inserting a copy of this AD into the RFM, or inserting a copy... (817) 222-5961, for information about previously approved alternative methods of compliance. (c) The...

  2. Degradation Behavior and Accelerated Weathering of Composite Boards Produced from Waste Tetra Pak® Packaging Materials

    Treesearch

    Nural Yilgor; Coskun Kose; Evren Terzi; Aysel Kanturk Figen; Rebecca Ibach; S. Nami Kartal; Sabriye Piskin

    2014-01-01

    Manufacturing panels from Tetra Pak® (TP) packaging material might be an alternative to conventional wood-based panels. This study evaluated some chemical and physical properties as well as biological, weathering, and fire performance of panels with and without zinc borate (ZnB) by using shredded TP packaging cartons. Such packaging material, a worldwide well-known...

  3. 49 CFR 173.4a - Excepted quantities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of withstanding without leakage the pressure differential specified in § 173.27(c) of this part. (b... ice), and lithium batteries and cells. (c) Inner packaging limits. The maximum quantity of hazardous..., rigid outer packaging. (5) Placement of the material in the package or packing different materials in...

  4. 49 CFR 178.608 - Vibration standard.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...

  5. 49 CFR 178.608 - Vibration standard.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...

  6. 49 CFR 178.608 - Vibration standard.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...

  7. 49 CFR 178.608 - Vibration standard.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...

  8. Software management tools: Lessons learned from use

    NASA Technical Reports Server (NTRS)

    Reifer, D. J.; Valett, J.; Knight, J.; Wenneson, G.

    1985-01-01

    Experience in inserting software project planning tools into more than 100 projects producing mission critical software are discussed. The problems the software project manager faces are listed along with methods and tools available to handle them. Experience is reported with the Project Manager's Workstation (PMW) and the SoftCost-R cost estimating package. Finally, the results of a survey, which looked at what could be done in the future to overcome the problems experienced and build a set of truly useful tools, are presented.

  9. Retroviral insertions in the VISION database identify molecular pathways in mouse lymphoid leukemia and lymphoma

    PubMed Central

    Weiser, Keith C.; Liu, Bin; Hansen, Gwenn M.; Skapura, Darlene; Hentges, Kathryn E.; Yarlagadda, Sujatha; Morse III, Herbert C.

    2007-01-01

    AKXD recombinant inbred (RI) strains develop a variety of leukemias and lymphomas due to somatically acquired insertions of retroviral DNA into the genome of hematopoetic cells that can mutate cellular proto-oncogenes and tumor suppressor genes. We generated a new set of tumors from nine AKXD RI strains selected for their propensity to develop B-cell tumors, the most common type of human hematopoietic cancers. We employed a PCR technique called viral insertion site amplification (VISA) to rapidly isolate genomic sequence at the site of provirus insertion. Here we describe 550 VISA sequence tags (VSTs) that identify 74 common insertion sites (CISs), of which 21 have not been identified previously. Several suspected proto-oncogenes and tumor suppressor genes lie near CISs, providing supportive evidence for their roles in cancer. Furthermore, numerous previously uncharacterized genes lie near CISs, providing a pool of candidate disease genes for future research. Pathway analysis of candidate genes identified several signaling pathways as common and powerful routes to blood cancer, including Notch, E-protein, NFκB, and Ras signaling. Misregulation of several Notch signaling genes was confirmed by quantitative RT-PCR. Our data suggest that analyses of insertional mutagenesis on a single genetic background are biased toward the identification of cooperating mutations. This tumor collection represents the most comprehensive study of the genetics of B-cell leukemia and lymphoma development in mice. We have deposited the VST sequences, CISs in a genome viewer, histopathology, and molecular tumor typing data in a public web database called VISION (Viral Insertion Sites Identifying Oncogenes), which is located at http://www.mouse-genome.bcm.tmc.edu/vision. PMID:17926094

  10. Retroviral insertions in the VISION database identify molecular pathways in mouse lymphoid leukemia and lymphoma.

    PubMed

    Weiser, Keith C; Liu, Bin; Hansen, Gwenn M; Skapura, Darlene; Hentges, Kathryn E; Yarlagadda, Sujatha; Morse Iii, Herbert C; Justice, Monica J

    2007-10-01

    AKXD recombinant inbred (RI) strains develop a variety of leukemias and lymphomas due to somatically acquired insertions of retroviral DNA into the genome of hematopoetic cells that can mutate cellular proto-oncogenes and tumor suppressor genes. We generated a new set of tumors from nine AKXD RI strains selected for their propensity to develop B-cell tumors, the most common type of human hematopoietic cancers. We employed a PCR technique called viral insertion site amplification (VISA) to rapidly isolate genomic sequence at the site of provirus insertion. Here we describe 550 VISA sequence tags (VSTs) that identify 74 common insertion sites (CISs), of which 21 have not been identified previously. Several suspected proto-oncogenes and tumor suppressor genes lie near CISs, providing supportive evidence for their roles in cancer. Furthermore, numerous previously uncharacterized genes lie near CISs, providing a pool of candidate disease genes for future research. Pathway analysis of candidate genes identified several signaling pathways as common and powerful routes to blood cancer, including Notch, E-protein, NFkappaB, and Ras signaling. Misregulation of several Notch signaling genes was confirmed by quantitative RT-PCR. Our data suggest that analyses of insertional mutagenesis on a single genetic background are biased toward the identification of cooperating mutations. This tumor collection represents the most comprehensive study of the genetics of B-cell leukemia and lymphoma development in mice. We have deposited the VST sequences, CISs in a genome viewer, histopathology, and molecular tumor typing data in a public web database called VISION (Viral Insertion Sites Identifying Oncogenes), which is located at http://www.mouse-genome.bcm.tmc.edu/vision .

  11. National Biocontainment Training Center

    DTIC Science & Technology

    2014-06-01

    of novel antimicrobial compounds with antibacterial activity against TB (Vijayakumar, et al., Dec. 2013, Tuberculosis). She has also developed...Nanoluc. (a) insert the Nanoluc after the signal peptide , (b) insert the Nanoluc before the RSKR site, (c) insert the Nanoluc before the RRLL site...biological safe techniques. This training took place in Dallas, Texas. Trainers: Vickie Jones and Jason Hardcastle. Food and Drug Administration (FDA

  12. Optical clock distribution in supercomputers using polyimide-based waveguides

    NASA Astrophysics Data System (ADS)

    Bihari, Bipin; Gan, Jianhua; Wu, Linghui; Liu, Yujie; Tang, Suning; Chen, Ray T.

    1999-04-01

    Guided-wave optics is a promising way to deliver high-speed clock-signal in supercomputer with minimized clock-skew. Si- CMOS compatible polymer-based waveguides for optoelectronic interconnects and packaging have been fabricated and characterized. A 1-to-48 fanout optoelectronic interconnection layer (OIL) structure based on Ultradel 9120/9020 for the high-speed massive clock signal distribution for a Cray T-90 supercomputer board has been constructed. The OIL employs multimode polymeric channel waveguides in conjunction with surface-normal waveguide output coupler and 1-to-2 splitters. Surface-normal couplers can couple the optical clock signals into and out from the H-tree polyimide waveguides surface-normally, which facilitates the integration of photodetectors to convert optical-signal to electrical-signal. A 45-degree surface- normal couplers has been integrated at each output end. The measured output coupling efficiency is nearly 100 percent. The output profile from 45-degree surface-normal coupler were calculated using Fresnel approximation. the theoretical result is in good agreement with experimental result. A total insertion loss of 7.98 dB at 850 nm was measured experimentally.

  13. Numerical investigation of heat transfer and friction factor characteristics in a circular tube fitted with V-cut twisted tape inserts.

    PubMed

    Salman, Sami D; Kadhum, Abdul Amir H; Takriff, Mohd S; Mohamad, Abu Bakar

    2013-01-01

    Numerical investigation of the heat transfer and friction factor characteristics of a circular fitted with V-cut twisted tape (VCT) insert with twist ratio (y = 2.93) and different cut depths (w = 0.5, 1, and 1.5 cm) were studied for laminar flow using CFD package (FLUENT-6.3.26). The data obtained from plain tube were verified with the literature correlation to ensure the validation of simulation results. Classical twisted tape (CTT) with different twist ratios (y = 2.93, 3.91, 4.89) were also studied for comparison. The results show that the enhancement of heat transfer rate induced by the classical and V-cut twisted tape inserts increases with the Reynolds number and decreases with twist ratio. The results also revealed that the V-cut twisted tape with twist ratio y = 2.93 and cut depth w = 0.5 cm offered higher heat transfer rate with significant increases in friction factor than other tapes. In addition the results of V-cut twist tape compared with experimental and simulated data of right-left helical tape inserts (RLT), it is found that the V-cut twist tape offered better thermal contact between the surface and the fluid which ultimately leads to a high heat transfer coefficient. Consequently, 107% of maximum heat transfer was obtained by using this configuration.

  14. Numerical Investigation of Heat Transfer and Friction Factor Characteristics in a Circular Tube Fitted with V-Cut Twisted Tape Inserts

    PubMed Central

    Salman, Sami D.; Kadhum, Abdul Amir H.; Takriff, Mohd S.; Mohamad, Abu Bakar

    2013-01-01

    Numerical investigation of the heat transfer and friction factor characteristics of a circular fitted with V-cut twisted tape (VCT) insert with twist ratio (y = 2.93) and different cut depths (w = 0.5, 1, and 1.5 cm) were studied for laminar flow using CFD package (FLUENT-6.3.26). The data obtained from plain tube were verified with the literature correlation to ensure the validation of simulation results. Classical twisted tape (CTT) with different twist ratios (y = 2.93, 3.91, 4.89) were also studied for comparison. The results show that the enhancement of heat transfer rate induced by the classical and V-cut twisted tape inserts increases with the Reynolds number and decreases with twist ratio. The results also revealed that the V-cut twisted tape with twist ratio y = 2.93 and cut depth w = 0.5 cm offered higher heat transfer rate with significant increases in friction factor than other tapes. In addition the results of V-cut twist tape compared with experimental and simulated data of right-left helical tape inserts (RLT), it is found that the V-cut twist tape offered better thermal contact between the surface and the fluid which ultimately leads to a high heat transfer coefficient. Consequently, 107% of maximum heat transfer was obtained by using this configuration. PMID:24078795

  15. Take Care of Your Feet for a Lifetime

    MedlinePlus

    ... footwear: You may need special shoes or shoe inserts to support your feet. Medicare Part B insurance ... some of the cost of special shoes or inserts. Ask your doctor if your insurance plan will ...

  16. SHIPMENT OF TWO DOE-STD-3013 CONTAINERS IN A 9977 TYPE B PACKAGE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abramczyk, G.; Bellamy, S.; Loftin, B.

    2011-06-06

    The 9977 is a certified Type B Packaging authorized to ship uranium and plutonium in metal and oxide forms. Historically, the standard container for these materials has been the DOE-STD-3013 which was specifically designed for the long term storage of plutonium bearing materials. The Department of Energy has used the 9975 Packaging containing a single 3013 container for the transportation and storage of these materials. In order to reduce container, shipping, and storage costs, the 9977 Packaging is being certified for transportation and storage of two 3013 containers. The challenges and risks of this content and the 9977s ability tomore » meet the Code of Federal Regulations for the transport of these materials are presented.« less

  17. On the accurate analysis of vibroacoustics in head insert gradient coils.

    PubMed

    Winkler, Simone A; Alejski, Andrew; Wade, Trevor; McKenzie, Charles A; Rutt, Brian K

    2017-10-01

    To accurately analyze vibroacoustics in MR head gradient coils. A detailed theoretical model for gradient coil vibroacoustics, including the first description and modeling of Lorentz damping, is introduced and implemented in a multiphysics software package. Numerical finite-element method simulations were used to establish a highly accurate vibroacoustic model in head gradient coils in detail, including the newly introduced Lorentz damping effect. Vibroacoustic coupling was examined through an additional modal analysis. Thorough experimental studies were used to validate simulations. Average experimental sound pressure levels (SPLs) and accelerations over the 0-3000 Hz frequency range were 97.6 dB, 98.7 dB, and 95.4 dB, as well as 20.6 g, 8.7 g, and 15.6 g for the X-, Y-, and Z-gradients, respectively. A reasonable agreement between simulations and measurements was achieved. Vibroacoustic coupling showed a coupled resonance at 2300 Hz for the Z-gradient that is responsible for a sharp peak and the highest SPL value in the acoustic spectrum. We have developed and used more realistic multiphysics simulation methods to gain novel insights into the underlying concepts for vibroacoustics in head gradient coils, which will permit improved analyses of existing gradient coils and novel SPL reduction strategies for future gradient coil designs. Magn Reson Med 78:1635-1645, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. 21 CFR 355.20 - Packaging conditions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Packaging conditions. 355.20 Section 355.20 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR... accord with § 355.60. (b) Tight container packaging. To minimize moisture contamination, all fluoride...

  19. 49 CFR 173.453 - Fissile materials-exceptions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... noted. (a) An individual package containing 2 grams or less of fissile material. (b) An individual or bulk packaging containing 15 grams or less of fissile material provided the package has at least 200 grams of solid nonfissile material for every gram of fissile material. Lead, beryllium, graphite, and...

  20. 49 CFR 173.453 - Fissile materials-exceptions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... noted. (a) An individual package containing 2 grams or less of fissile material. (b) An individual or bulk packaging containing 15 grams or less of fissile material provided the package has at least 200 grams of solid nonfissile material for every gram of fissile material. Lead, beryllium, graphite, and...

  1. 49 CFR 173.453 - Fissile materials-exceptions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... noted. (a) An individual package containing 2 grams or less of fissile material. (b) An individual or bulk packaging containing 15 grams or less of fissile material provided the package has at least 200 grams of solid nonfissile material for every gram of fissile material. Lead, beryllium, graphite, and...

  2. 49 CFR 173.453 - Fissile materials-exceptions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... noted. (a) An individual package containing 2 grams or less of fissile material. (b) An individual or bulk packaging containing 15 grams or less of fissile material provided the package has at least 200 grams of solid nonfissile material for every gram of fissile material. Lead, beryllium, graphite, and...

  3. 49 CFR 173.453 - Fissile materials-exceptions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... noted. (a) An individual package containing 2 grams or less of fissile material. (b) An individual or bulk packaging containing 15 grams or less of fissile material provided the package has at least 200 grams of solid nonfissile material for every gram of fissile material. Lead, beryllium, graphite, and...

  4. 49 CFR 178.606 - Stacking test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Stacking test. 178.606 Section 178.606... Packagings and Packages § 178.606 Stacking test. (a) General. All packaging design types other than bags must be subjected to a stacking test. (b) Number of test samples. Three test samples are required for each...

  5. 49 CFR 178.985 - Vibration test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Vibration test. 178.985 Section 178.985... Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A sample Large...

  6. 49 CFR 173.340 - Tear gas devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Tear gas devices. 173.340 Section 173.340... SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.340 Tear gas devices. (a) Packagings for tear gas devices must be approved prior to initial transportation by the Associate Administrator. (b...

  7. 49 CFR 178.985 - Vibration test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Vibration test. 178.985 Section 178.985... Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A sample Large...

  8. 49 CFR 178.985 - Vibration test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Vibration test. 178.985 Section 178.985... Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A sample Large...

  9. 49 CFR 178.985 - Vibration test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Vibration test. 178.985 Section 178.985... Testing of Large Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A...

  10. 49 CFR 178.985 - Vibration test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Vibration test. 178.985 Section 178.985... Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A sample Large...

  11. Mass Spec Studio for Integrative Structural Biology

    PubMed Central

    Rey, Martial; Sarpe, Vladimir; Burns, Kyle; Buse, Joshua; Baker, Charles A.H.; van Dijk, Marc; Wordeman, Linda; Bonvin, Alexandre M.J.J.; Schriemer, David C.

    2015-01-01

    SUMMARY The integration of biophysical data from multiple sources is critical for developing accurate structural models of large multiprotein systems and their regulators. Mass spectrometry (MS) can be used to measure the insertion location for a wide range of topographically sensitive chemical probes, and such insertion data provide a rich, but disparate set of modeling restraints. We have developed a software platform that integrates the analysis of label-based MS data with protein modeling activities (Mass Spec Studio). Analysis packages can mine any labeling data from any mass spectrometer in a proteomics-grade manner, and link labeling methods with data-directed protein interaction modeling using HADDOCK. Support is provided for hydrogen/ deuterium exchange (HX) and covalent labeling chemistries, including novel acquisition strategies such as targeted HX-tandem MS (MS2) and data-independent HX-MS2. The latter permits the modeling of highly complex systems, which we demonstrate by the analysis of microtubule interactions. PMID:25242457

  12. A new FPGA architecture suitable for DSP applications

    NASA Astrophysics Data System (ADS)

    Liyun, Wang; Jinmei, Lai; Jiarong, Tong; Pushan, Tang; Xing, Chen; Xueyan, Duan; Liguang, Chen; Jian, Wang; Yuan, Wang

    2011-05-01

    A new FPGA architecture suitable for digital signal processing applications is presented. DSP modules can be inserted into FPGA conveniently with the proposed architecture, which is much faster when used in the field of digital signal processing compared with traditional FPGAs. An advanced 2-level MUX (multiplexer) is also proposed. With the added SLEEP MODE PASS to traditional 2-level MUX, static leakage is reduced. Furthermore, buffers are inserted at early returns of long lines. With this kind of buffer, the delay of the long line is improved by 9.8% while the area increases by 4.37%. The layout of this architecture has been taped out in standard 0.13 μm CMOS technology successfully. The die size is 6.3 × 4.5 mm2 with the QFP208 package. Test results show that performances of presented classical DSP cases are improved by 28.6%-302% compared with traditional FPGAs.

  13. Drugs dispensed at the Division of Neonatology at University Hospital in Río Cuarto, Córdoba, Argentina.

    PubMed

    Fungo, Marta Stella Maris; Vega, Elena María

    2013-04-01

    The objective was to analyze the number of drugs dispensed by the Pharmacy Department to the Neonatology Division, to find out if the use of these drugs is described on the package insert approved by the Administración Nacional de Medicamentos, Alimentos y Tecnología, ANMAT (Drug, Food and Technology Administration of Argentina) and to compare such information with that provided by Medical Associations and Commissions. Analytical, observational and retrospective study in which drugs were analyzed based on dosage units, costs and relevance in the 2011 annual budget. We analyzed the information found in ANMAT-approved label inserts, in the Neonatal Pharmacopeia of the Sociedad Argentina de Pediatría and in the Formularies of the Confederación Médica Argentina and the Comisión Nacional del Medicamento (National Medication Commission). A total of 102 drugs (91 drug substances) were dispensed throughout 2011. Drugs most commonly supplied were: antiinfective agents for systemic use (24.51%), agents for the blood and blood forming organs, cardiovascular system, and nervous system (12.72% each). The total expenditure was ARS 263,285.52. Only 21 drugs accounted for 90.73% of the cost. Out of the 14 drugs in this group, only 1 had information related to its use in neonatology in all its labels (package inserts), only 4 in some of their product information and there was no information at all in any of the remaining 9 drugs. The Neonatal Pharmacopeia reported on 12 of the 14 drugs, while the Formularies made a reference to 9 of the 14 drugs. The most widely used drugs were antiinfectives for systemic use. A total of 21 drugs accounted for 90.73% of the annual cost in drugs. Out of 14, only 1 had information of its use in neonatology in all its labels and 9 corresponded to off-label use.

  14. System for Packaging Planetary Samples for Return to Earth

    NASA Technical Reports Server (NTRS)

    Badescu, Mircea; Bar-Cohen, Yoseph; Backes, paul G.; Sherrit, Stewart; Bao, Xiaoqi; Scott, James S.

    2010-01-01

    A system is proposed for packaging material samples on a remote planet (especially Mars) in sealed sample tubes in preparation for later return to Earth. The sample tubes (Figure 1) would comprise (1) tubes initially having open tops and closed bottoms; (2) small, bellows-like collapsible bodies inside the tubes at their bottoms; and (3) plugs to be eventually used to close the tops of the tubes. The top inner surface of each tube would be coated with solder. The side of each plug, which would fit snugly into a tube, would feature a solder-filled ring groove. The system would include equipment for storing, manipulating, filling, and sealing the tubes. The containerization system (see Figure 2) will be organized in stations and will include: the storage station, the loading station, and the heating station. These stations can be structured in circular or linear pattern to minimize the manipulator complexity, allowing for compact design and mass efficiency. The manipulation of the sample tube between stations is done by a simple manipulator arm. The storage station contains the unloaded sample tubes and the plugs before sealing as well as the sealed sample tubes with samples after loading and sealing. The chambers at the storage station also allow for plug insertion into the sample tube. At the loading station the sample is poured or inserted into the sample tube and then the tube is topped off. At the heating station the plug is heated so the solder ring melts and seals the plug to the sample tube. The process is performed as follows: Each tube is filled or slightly overfilled with sample material and the excess sample material is wiped off the top. Then, the plug is inserted into the top section of the tube packing the sample material against the collapsible bellowslike body allowing the accommodation of the sample volume. The plug and the top of the tube are heated momentarily to melt the solder in order to seal the tube.

  15. Is antibiotic prophylaxis mandatory after the insertion of levonorgestrel-releasing intrauterine systemin order to decrease the risk of pelvic inflammatory disease?

    PubMed Central

    Munteanu, O; Radulescu, L; Bodean, O; Cirstoiu, C; Secara, D; Cirstoiu, M

    2013-01-01

    Abstract Objective: This study was undertaken in order to determine if antibiotic prophylaxis is mandatory, after the insertion of levonorgestrel-releasing intrauterine system in order to decrease the risk of pelvic inflammatory disease. Materials and methods: We prospectively evaluated 44 patients, admitted in the Bucharest Emergency Hospital between the 1ⁱ of February 2012 and the 1ⁱ of October 2012, in whom the levonorgestrel-releasing intrauterine system was inserted. The patients enrolled were divided into two groups. In group A, a number of 22 patients, received, after the insertion of levonorgestrel-releasing intrauterine system, 875mg Amoxicillin Trihydrate + 125 mg Potassium Clavulanate, a dose every 12 hours for 5 days. Group B was represented by the other 22 patients who did not receive antibiotic prophylaxis. All patients were reevaluated at 4 and 12 weeks after the insertion of levonorgestrel-releasing intrauterine system. Results: During the first 4 weeks after the insertion of levonorgestrel-releasing intrauterine system only two patients, one from group A and one from group B were diagnosed with pelvic inflammatory disease. At a second follow up visit – 12 weeks after the insertion of levonorgestrel-releasing intrauterine system, no other patient was diagnosed with pelvic inflammatory disease. Conclusion: Antibiotic prophylaxis is not mandatory, after the insertion of levonorgestrel-releasing intrauterine system in order to decrease the risk of pelvic inflammatory disease. PMID:24868262

  16. Influence of carbon monoxide on the colour stability of defrosted yellowfin tuna (Thunnus albacares) muscle stored under aerobic and anaerobic conditions.

    PubMed

    Neethling, Nikki E; Hoffman, Louwrens C; Britz, Trevor J; O'Neill, Bernadette

    2015-06-01

    The use of carbon monoxide (CO) and various packaging types has been suggested to improve/stabilise the colour and oxidative processes of red meats, thereby improving the retail value and revenue. The main aim of this study was to investigate the influence of packaging type and CO treatment on the colour and oxidative stability of tuna. The addition of CO significantly increased the redness (a(*) ) of the tuna steaks but the redness was not equally stable for all treatments. The aerobically packaged steaks showed a temporal decrease in redness while the redness of anaerobically packaged steaks remained relatively stable. The addition of CO did not significantly affect (P >0.05) the brownness (b(*) ) (with one exception) and lightness (L(*) ) of the steaks. The anaerobically packaged steaks showed a significant difference (P <0.05) in the b(*) values. No significant differences (P >0.05) in lipid or protein oxidation were observed between treatments. The aerobically packaged steaks had a significant temporal increase (P <0.05) in lipid oxidation while no such trend was apparent in the anaerobically packaged steaks. Protein oxidation remained relatively stable over time for both aerobically and anaerobically packaged steaks. Storing CO treated tuna steaks in anaerobic packaging can improve the oxidative and colour stability of tuna. Such treatment can reduce spoilage and wastage thereby potentially increasing revenue. © 2014 Society of Chemical Industry.

  17. [Mutants of bacterium Azospirillum brasilense Sp245 with Omegon insertion in mmsB or fabG genes of lipid metabolism are defective in motility and flagellation].

    PubMed

    Kovtunov, E A; Shelud'ko, A V; Chernyshova, M P; Petrova, L P; Katsy, E I

    2013-11-01

    Bacteria Azospirillum brasilense have mixed flagellation: in addition to the polar flagellum, numerous lateral flagella are formed in their cells on medium with increased density. Flagella determine the active swimming and swarming capacities of azospirilla. Using A. brasilense Sp245 as an example, we showed that the Omegon-Km artificial transposon insertion into the chromosomal gene for 3-hydroxyisobutyrate dehydrogenase (mmsB) was concurrent with the appearance of significant defects in the formation of polar flagella and with the paralysis of lateral flagella. The Sp245 mutant with the Omegon insertion into the plasmid AZOBR_p1-borne gene for 3-oxoacyl-[acyl-carrier protein]-reductase (fabG) showed the complete loss of flagella and the swarming capacity, as well as significant defects in polar flagellar assembly (though some cells are still motile in liquid medium). The viability of the A. brasilense Sp245 mutants with the Omegon insertion into the mmsB or fabG gene was not reduced. No considerable differences in the fatty acid composition of whole cell lipid extracts were found for the A. brasilense Sp245 strain and its mmsB and fabG mutants.

  18. 49 CFR 173.467 - Tests for demonstrating the ability of Type B and fissile materials packagings to withstand...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Tests for demonstrating the ability of Type B and fissile materials packagings to withstand accident conditions in transportation. 173.467 Section 173.467 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  19. 49 CFR 173.467 - Tests for demonstrating the ability of Type B and fissile materials packagings to withstand...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Tests for demonstrating the ability of Type B and fissile materials packagings to withstand accident conditions in transportation. 173.467 Section 173.467 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  20. 21 CFR 1310.06 - Content of records and reports.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... exempted from §§ 1300.02(b)(28)(i)(D) or 1300.02(b)(28)(i)(E) during the preceding calendar year. (6) Data shall identify the specific isomer, salt or ester when applicable but quantitative data shall be....). (9) Number of dosage units (if drug product) (100 doses per package). (10) Package type (if drug...

  1. Constructing and Modifying Sequence Statistics for relevent Using informR in 𝖱

    PubMed Central

    Marcum, Christopher Steven; Butts, Carter T.

    2015-01-01

    The informR package greatly simplifies the analysis of complex event histories in 𝖱 by providing user friendly tools to build sufficient statistics for the relevent package. Historically, building sufficient statistics to model event sequences (of the form a→b) using the egocentric generalization of Butts’ (2008) relational event framework for modeling social action has been cumbersome. The informR package simplifies the construction of the complex list of arrays needed by the rem() model fitting for a variety of cases involving egocentric event data, multiple event types, and/or support constraints. This paper introduces these tools using examples from real data extracted from the American Time Use Survey. PMID:26185488

  2. Dry-film polymer waveguide for silicon photonics chip packaging.

    PubMed

    Hsu, Hsiang-Han; Nakagawa, Shigeru

    2014-09-22

    Polymer waveguide made by dry film process is demonstrated for silicon photonics chip packaging. With 8 μm × 11.5 μm core waveguide, little penalty is observed up to 25 Gbps before or after the light propagate through a 10-km long single-mode fiber (SMF). Coupling loss to SMF is 0.24 dB and 1.31 dB at the polymer waveguide input and output ends, respectively. Alignment tolerance for 0.5 dB loss increase is +/- 1.0 μm along both vertical and horizontal directions for the coupling from the polymer waveguide to SMF. The dry-film polymer waveguide demonstrates promising performance for silicon photonics chip packaging used in next generation optical multi-chip module.

  3. DNA Packaging Specificity of Bacteriophage N15 with an Excursion into the Genetics of a Cohesive End Mismatch

    PubMed Central

    Feiss, Michael; Young Min, Jea; Sultana, Sawsan; Patel, Priyal; Sippy, Jean

    2015-01-01

    During DNA replication by the λ-like bacteriophages, immature concatemeric DNA is produced by rolling circle replication. The concatemers are processed into mature chromosomes with cohesive ends, and packaged into prohead shells, during virion assembly. Cohesive ends are generated by the viral enzyme terminase, which introduces staggered nicks at cos, an approx. 200 bp-long sequence containing subsites cosQ, cosN and cosB. Interactions of cos subsites of immature concatemeric DNA with terminase orchestrate DNA processing and packaging. To initiate DNA packaging, terminase interacts with cosB and nicks cosN. The cohesive ends of N15 DNA differ from those of λ at 2/12 positions. Genetic experiments show that phages with chromosomes containing mismatched cohesive ends are functional. In at least some infections, the cohesive end mismatch persists through cyclization and replication, so that progeny phages of both allelic types are produced in the infected cell. N15 possesses an asymmetric packaging specificity: N15 DNA is not packaged by phages λ or 21, but surprisingly, N15-specific terminase packages λ DNA. Implications for genetic interactions among λ-like bacteriophages are discussed. PMID:26633301

  4. PIMMS (Pragmatic Insertional Mutation Mapping System) Laboratory Methodology a Readily Accessible Tool for Identification of Essential Genes in Streptococcus

    PubMed Central

    Blanchard, Adam M.; Egan, Sharon A.; Emes, Richard D.; Warry, Andrew; Leigh, James A.

    2016-01-01

    The Pragmatic Insertional Mutation Mapping (PIMMS) laboratory protocol was developed alongside various bioinformatics packages (Blanchard et al., 2015) to enable detection of essential and conditionally essential genes in Streptococcus and related bacteria. This extended the methodology commonly used to locate insertional mutations in individual mutants to the analysis of mutations in populations of bacteria. In Streptococcus uberis, a pyogenic Streptococcus associated with intramammary infection and mastitis in ruminants, the mutagen pGhost9:ISS1 was shown to integrate across the entire genome. Analysis of >80,000 mutations revealed 196 coding sequences, which were not be mutated and a further 67 where mutation only occurred beyond the 90th percentile of the coding sequence. These sequences showed good concordance with sequences within the database of essential genes and typically matched sequences known to be associated with basic cellular functions. Due to the broad utility of this mutagen and the simplicity of the methodology it is anticipated that PIMMS will be of value to a wide range of laboratories in functional genomic analysis of a wide range of Gram positive bacteria (Streptococcus, Enterococcus, and Lactococcus) of medical, veterinary, and industrial significance. PMID:27826289

  5. Development of an 83.2 MHz, 3.2 kW solid-state RF amplifier using Wilkinson power divider and combiner for a 10 MeV cyclotron

    NASA Astrophysics Data System (ADS)

    Song, Ho Seung; Ghergherehchi, Mitra; Oh, Seyoung; Chai, Jong Seo

    2017-03-01

    We design a stripline-type Wilkinson power divider and combiner for a 3.2 kW solid-state radio frequency (RF) amplifier module and optimize this setup. A Teflon-based printed circuit board is used in the power combiner to transmit high RF power efficiently in the limited space. The reflection coefficient (S11) and insertion loss (S21) related to impedance matching are characterized to determine the optimization process. The resulting two-way divider reflection coefficient and insertion loss were -48.00 dB and -3.22 dB, respectively. The two-way power combiner reflection coefficient and insertion loss were -20 dB and -3.3 dB, respectively. Moreover, the 3.2 kW solid-state RF power test results demonstrate that the proposed power divider and combiner exhibit a maximum efficiency value of 71.3% (combiner loss 5%) at 48 V supply voltage.

  6. W-band integrated circuit PIN switches

    NASA Astrophysics Data System (ADS)

    Tahim, R. S.; Pham, T.; Chang, K.

    1986-12-01

    Both single-pole single-throw (SPST) and single-pole double-throw (SPDT) PIN switches have been developed at W band using microstrip integrated circuits. In SPST configurations, these switches have less than 1 dB of insertion loss under forward-voltage conditions from 90 to 108 GHz. Isolation greater than 20 dB over 3 GHz and greater than 10 dB over 7 GHz has been achieved. In SPDT configurations, insertion loss of less than 2 dB and isolation of more than 15 dB over 10 GHz (90 to 110 GHz) have been achieved. Beam-lead PIN diodes were used. Major features included mechanical ruggedness, light weight, small size and low-cost manufacturing.

  7. An investigation of nonuniform dose deposition from an electron beam

    NASA Astrophysics Data System (ADS)

    Lilley, William; Luu, Kieu X.

    1994-08-01

    In a search for an explanation of nonuniform electron-beam dose deposition, the integrated tiger series (ITS) of coupled electron/photon Monte Carlo transport codes was used to calculate energy deposition in the package materials of an application-specific integrated circuit (ASIC) while the thicknesses of some of the materials were varied. The thicknesses of three materials that were in the path of an electron-beam pulse were varied independently so that analysis could determine how the radiation dose measurements using thermoluminescent dosimeters (TLD's) would be affected. The three materials were chosen because they could vary during insertion of the die into the package or during the process of taking dose measurements. The materials were aluminum, HIPEC (a plastic), and silver epoxy. The calculations showed that with very small variations in thickness, the silver epoxy had a large effect on the dose uniformity over the area of the die.

  8. [The Russian gene pool: gene geography of Alu-insertions (ACE, APOA1, B65, PV92 TPA25)].

    PubMed

    Solov'eva, D S; Balanovskaia, E V; Kuznetsova, M A; Vasinskaia, O A; Frolova, S A; Pocheshkhova, E A; Evseeva, I V; Boldyreva, M N; Balanovskiĭ, O P

    2010-01-01

    The analysis of five Alu insertion loci (ACE, AP4OA1, B65, PV92, TPA25) has been carried out for the first time in 10 Russian populations (1088 individuals), covered all parts of historical area of the Russian ethnos. Depending on locus, Russian populations exhibit similarity with their western (European populations) or with the eastern (populations of the Ural region) neighbors. Considering frequencies of the studied Alu-insertions, Russian gene pool exhibits low variation: average difference between populations is d = 0.007, whereas on classical markers, mtDNA and Y chromosome heterogeneity of Russian gene pool is essentially higher (0.013, 0.033 and 0.142 respectively). Therefore, this set of five Alu insertions has lower variability on the intra-ethnic level. However in inter-ethnic comparisons the clear pattern was obtained: 13 Eastern European ethnic groups formed three clusters, according with their historical and geographical position--East Slavic, Caucasian and South Ural clusters. The obtained data confirms efficiency of using Alu insertions for studying genetic differentiation and history of a gene pool of the Eastern European populations.

  9. TM-pass polarizer based on multilayer graphene polymer waveguide

    NASA Astrophysics Data System (ADS)

    Cai, Ke-su; Li, Yue-e.; Wei, Wen-jing; Mu, Xi-jiao; Ma, A.-ning; Wang, Zhong; Song, Dan-ming

    2018-05-01

    A TM-pass polarizer based on multilayer graphene polymer waveguide is proposed and theoretically analyzed. The mode properties, the extinction ratio, the insertion loss and the bandwidth are also discussed. The results show that a TM-pass polarizer, which only guides the TM mode, can be achieved by multilayer graphene polymer waveguide. With length of 150 μm, the proposed polarizer can achieve extinction ratio of 33 dB and insertion loss of 0.5 dB at optical wavelength of 1.55 μm. This device has an excellent performance, including large extinction ratio and low insertion loss within the spectral range from 1.45 μm to 1.6 μm.

  10. 10 CFR 71.15 - Exemption from classification as fissile material.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... subject to all other requirements of this part, except as noted. (a) Individual package containing 2 grams or less fissile material. (b) Individual or bulk packaging containing 15 grams or less of fissile material provided the package has at least 200 grams of solid nonfissile material for every gram of fissile...

  11. 10 CFR 71.15 - Exemption from classification as fissile material.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... subject to all other requirements of this part, except as noted. (a) Individual package containing 2 grams or less fissile material. (b) Individual or bulk packaging containing 15 grams or less of fissile material provided the package has at least 200 grams of solid nonfissile material for every gram of fissile...

  12. 10 CFR 71.15 - Exemption from classification as fissile material.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... subject to all other requirements of this part, except as noted. (a) Individual package containing 2 grams or less fissile material. (b) Individual or bulk packaging containing 15 grams or less of fissile material provided the package has at least 200 grams of solid nonfissile material for every gram of fissile...

  13. 10 CFR 71.15 - Exemption from classification as fissile material.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... subject to all other requirements of this part, except as noted. (a) Individual package containing 2 grams or less fissile material. (b) Individual or bulk packaging containing 15 grams or less of fissile material provided the package has at least 200 grams of solid nonfissile material for every gram of fissile...

  14. 10 CFR 71.15 - Exemption from classification as fissile material.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... subject to all other requirements of this part, except as noted. (a) Individual package containing 2 grams or less fissile material. (b) Individual or bulk packaging containing 15 grams or less of fissile material provided the package has at least 200 grams of solid nonfissile material for every gram of fissile...

  15. 49 CFR 178.3 - Marking of packagings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... packagings. (a) Each packaging represented as manufactured to a DOT specification or a UN standard must be... identifying the standards or specification (e.g. UN 1A1, DOT 4B240ET, etc.). (2) Unless otherwise specified in... authorized, the symbol of the approval agency certifying compliance with a UN standard. Symbols, if used...

  16. 49 CFR 178.3 - Marking of packagings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... packagings. (a) Each packaging represented as manufactured to a DOT specification or a UN standard must be... identifying the standards or specification (e.g. UN 1A1, DOT 4B240ET, etc.). (2) Unless otherwise specified in... compliance with a UN standard. Symbols, if used, must be registered with the Associate Administrator. Unless...

  17. 49 CFR 178.3 - Marking of packagings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... packagings. (a) Each packaging represented as manufactured to a DOT specification or a UN standard must be... identifying the standards or specification (e.g. UN 1A1, DOT 4B240ET, etc.). (2) Unless otherwise specified in... authorized, the symbol of the approval agency certifying compliance with a UN standard. Symbols, if used...

  18. 49 CFR 178.3 - Marking of packagings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... packagings. (a) Each packaging represented as manufactured to a DOT specification or a UN standard must be... identifying the standards or specification (e.g. UN 1A1, DOT 4B240ET, etc.). (2) Unless otherwise specified in... compliance with a UN standard. Symbols, if used, must be registered with the Associate Administrator. Unless...

  19. 10 CFR 835.405 - Receipt of packages containing radioactive material.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Receipt of packages containing radioactive material. 835.405 Section 835.405 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Monitoring of...) Measurements of the radiation levels, if the package contains a Type B quantity (as defined at 10 CFR 71.4) of...

  20. 10 CFR 835.405 - Receipt of packages containing radioactive material.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Receipt of packages containing radioactive material. 835.405 Section 835.405 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Monitoring of...) Measurements of the radiation levels, if the package contains a Type B quantity (as defined at 10 CFR 71.4) of...

  1. 10 CFR 835.405 - Receipt of packages containing radioactive material.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Receipt of packages containing radioactive material. 835.405 Section 835.405 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Monitoring of...) Measurements of the radiation levels, if the package contains a Type B quantity (as defined at 10 CFR 71.4) of...

  2. 10 CFR 835.405 - Receipt of packages containing radioactive material.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Receipt of packages containing radioactive material. 835.405 Section 835.405 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Monitoring of...) Measurements of the radiation levels, if the package contains a Type B quantity (as defined at 10 CFR 71.4) of...

  3. 10 CFR 835.405 - Receipt of packages containing radioactive material.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Receipt of packages containing radioactive material. 835.405 Section 835.405 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Monitoring of...) Measurements of the radiation levels, if the package contains a Type B quantity (as defined at 10 CFR 71.4) of...

  4. 78 FR 56817 - Paper and Paper-Based Packaging Promotion, Research and Information Order; Referendum Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-16

    ...-11-0069; FR-B] RIN 0581-AD21 Paper and Paper-Based Packaging Promotion, Research and Information... issuance of a proposed Paper and Paper-Based Packaging Promotion, Research and Information Order (Order) is... FURTHER INFORMATION CONTACT: Kimberly Coy, Marketing Specialist, Promotion and Economics Division, Fruit...

  5. Active packaging from chitosan-titanium dioxide nanocomposite film for prolonging storage life of tomato fruit.

    PubMed

    Kaewklin, Patinya; Siripatrawan, Ubonrat; Suwanagul, Anawat; Lee, Youn Suk

    2018-06-01

    The feasibility of active packaging from chitosan (CS) and chitosan containing nanosized titanium dioxide (CT) to maintain quality and extend storage life of climacteric fruit was investigated. The CT nanocomposite film and CS film were fabricated using a solution casting method and used as active packaging to delay ripening process of cherry tomatoes. Changes in firmness, weight loss, a*/b* color, lycopene content, total soluble solid, ascorbic acid, and concentration of ethylene and carbon dioxide of the tomatoes packaged in CT film, CS film, and control (without CT or CS films) were monitored during storage at 20°C. Classification of fruit quality as a function of different packaging treatments was visualized using linear discriminant analysis. Tomatoes packaged in the CT film evolved lower quality changes than those in the CS film and control. The results suggested that the CT film exhibited ethylene photodegradation activity when exposed to UV light and consequently delayed the ripening process and changes in the quality of the tomatoes. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. A linear 180 nm SOI CMOS antenna switch module using integrated passive device filters for cellular applications

    NASA Astrophysics Data System (ADS)

    Jie, Cui; Lei, Chen; Peng, Zhao; Xu, Niu; Yi, Liu

    2014-06-01

    A broadband monolithic linear single pole, eight throw (SP8T) switch has been fabricated in 180 nm thin film silicon-on-insulator (SOI) CMOS technology with a quad-band GSM harmonic filter in integrated passive devices (IPD) technology, which is developed for cellular applications. The antenna switch module (ASM) features 1.2 dB insertion loss with filter on 2G bands and 0.4 dB insertion loss in 3G bands, less than -45 dB isolation and maximum -103 dB intermodulation distortion for mobile front ends by applying distributed architecture and adaptive supply voltage generator.

  7. Gluten content of medications.

    PubMed

    Cruz, Joseph E; Cocchio, Craig; Lai, Pak Tsun; Hermes-DeSantis, Evelyn

    2015-01-01

    The establishment of a database for the identification of the presence of gluten in excipients of prescription medications is described. While resources are available to ascertain the gluten content of a given medication, these resources are incomplete and often do not contain a source and date of contact. The drug information service (DIS) at Robert Wood Johnson University Hospital (RWJUH) determined that directly contacting the manufacturer of a product is the best method to determine the gluten content of medications. The DIS sought to establish a resource for use within the institution and create directions for obtaining this information from manufacturers to ensure uniformity of the data collected. To determine the gluten content of a medication, the DIS analyzed the manufacturer's package insert to identify any statement indicating that the product contained gluten or inactive ingredients from known sources of gluten. If there was any question about the source of an inactive ingredient or if no information about gluten content appeared in the package insert, the manufacturer of the particular formulation of the queried medication was contacted to provide clarification. Manufacturers' responses were collected, and medications were categorized as "gluten free," "contains gluten," or "possibly contains gluten." To date, the DIS at RWJUH has received queries about 84 medications and has cataloged their gluten content. The DIS at RWJUH developed a database that categorizes the gluten status of medications, allowing clinicians to easily identify drugs that are safe for patients with celiac disease. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  8. Evaluation of preferable insertion routes for esophagogastroduodenoscopy using ultrathin endoscopes

    PubMed Central

    Ono, Satoshi; Niimi, Keiko; Fujishiro, Mitsuhiro; Takahashi, Yu; Sakaguchi, Yoshiki; Nakayama, Chiemi; Minatsuki, Chihiro; Matsuda, Rie; Hirayama-Asada, Itsuko; Tsuji, Yosuke; Mochizuki, Satoshi; Kodashima, Shinya; Yamamichi, Nobutake; Ozeki, Atsuko; Matsumoto, Lumine; Ohike, Yumiko; Yamazaki, Tsutomu; Koike, Kazuhiko

    2014-01-01

    AIM: To evaluate the discomfort associated with esophagogastroduodenoscopy (EGD) using an ultrathin endoscope through different insertion routes. METHODS: This study (January 2012-March 2013) included 1971 consecutive patients [male/female (M/F), 1158/813, 57.5 ± 11.9 years] who visited a single institute for annual health checkups. Transnasal EGD was performed in 1394 patients and transoral EGD in 577. EGD-associated discomfort was assessed using a visual analog scale score (VAS score: 0-10). RESULTS: Multivariate analysis revealed gender (M vs F: 4.02 ± 2.15 vs 5.06 ± 2.43) as the only independent predictor of the VAS score in 180 patients who underwent EGD for the first time; whereas it revealed gender (M vs F 3.60 ± 2.20 vs 4.84 ± 2.37), operator, age group (A: < 39 years; B: 40-49 years; C: 50-59 years; D: 60-69 years; E: > 70 years; A/B/C/D/E: 4.99 ± 2.32/4.34 ± 2.49/4.19 ± 2.31/3.99 ± 2.27/3.63 ± 2.31), and type of insertion as independent predictors in the remaining patients. Subanalysis for gender, age group, and insertion route revealed that the VAS score decreased with age regardless of gender and insertion route, was high in female patients regardless of age and insertion route, and was low in males aged over 60 years who underwent transoral insertion. CONCLUSION: Although comprehensive analysis revealed that the insertion route may not be an independent predictor of the VAS score, transoral insertion may reduce EGD-associated discomfort in elderly patients. PMID:24803817

  9. Gene leopard nuclei (len P103) participating in control of disjunction and coiling of chromosomes in Drosophila

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omel`yanchuk, L.V.

    1995-12-01

    A lethal insertion of an element P[lArB], which caused nondisjunction and structural abnormalities in chromosomes in the neuroblasts of homozygous larvae, was found. The insertion was mapped to region 57B1-12 of the polytene map of chromosome 2 of Drosophila. The expression of the corresponding gene was found in testes, ovaries, and neural ganglia. 8 refs., 6 figs.

  10. Maturation of nitrogenase cofactor—the role of a class E radical SAM methyltransferase NifB

    PubMed Central

    Hu, Yilin; Ribbe, Markus W.

    2016-01-01

    Nitrogenase catalyzes the important reactions of N2-, CO- and CO2-reduction at its active cofactor site. Designated the M-cluster, this complex metallocofactor is assembled through the generation of a characteristic 8Fe-core prior to the insertion of Mo and homocitrate that completes the stoichiometry of the M-cluster. NifB catalyzes the critical step of radical SAM-dependent carbide insertion that occurs concomitant with the insertion a “9th” sulfur and the rearrangement/coupling of two 4Fe-clusters into a complete 8Fe-core of the M-cluster. Further categorization of a family of NifB proteins as a new class of radical SAM methyltransferases suggests a general function of these proteins in complex metallocofactor assembly and provides a new platform for unveiling unprecedented chemical reactions catalyzed by biological systems. PMID:26969410

  11. A Mutation in UL15 of Herpes Simplex Virus 1 That Reduces Packaging of Cleaved Genomes▿

    PubMed Central

    Yang, Kui; Wills, Elizabeth G.; Baines, Joel D.

    2011-01-01

    Herpesvirus genomic DNA is cleaved from concatemers that accumulate in infected cell nuclei. Genomic DNA is inserted into preassembled capsids through a unique portal vertex. Extensive analyses of viral mutants have indicated that intact capsids, the portal vertex, and all components of a tripartite terminase enzyme are required to both cleave and package viral DNA, suggesting that DNA cleavage and packaging are inextricably linked. Because the processes have not been functionally separable, it has been difficult to parse the roles of individual proteins in the DNA cleavage/packaging reaction. In the present study, a virus bearing the deletion of codons 400 to 420 of UL15, encoding a terminase component, was analyzed. This virus, designated vJB27, failed to replicate on noncomplementing cells but cleaved concatemeric DNA to ca. 35 to 98% of wild-type levels. No DNA cleavage was detected in cells infected with a UL15-null virus or a virus lacking UL15 codons 383 to 385, comprising a motif proposed to couple ATP hydrolysis to DNA translocation. The amount of vJB27 DNA protected from DNase I digestion was reduced compared to the wild-type virus by 6.5- to 200-fold, depending on the DNA fragment analyzed, thus indicating a profound defect in DNA packaging. Capsids containing viral DNA were not detected in vJB27-infected cells, as determined by electron microscopy. These data suggest that pUL15 plays an essential role in DNA translocation into the capsid and indicate that this function is separable from its role in DNA cleavage. PMID:21880766

  12. Negative regulatory loci coupling flagellin synthesis to flagellar assembly in Salmonella typhimurium.

    PubMed Central

    Gillen, K L; Hughes, K T

    1991-01-01

    The complex regulation of flagellin gene expression in Salmonella typhimurium was characterized in vivo by using lac transcriptional fusions to the two flagellin structural genes (fliC [H1] and fljB [H2]). Phase variation was measured as the rate of switching of flagellin gene expression. Switching frequencies varied from 1/500 per cell per generation to 1/10,000 per cell per generation depending on the particular insertion and the direction of switching. There is a 4- to 20-fold bias in favor of switching from the fljB(On) to the fljB(Off) orientation. Random Tn10dTc insertions were isolated which failed to express flagellin. While most of these insertions mapped to loci known to be required for flagellin expression, several new loci were identified. The presence of functional copies of all of the genes responsible for complete flagellar assembly, except the hook-associated proteins (flgK, flgL, and fliD gene products), were required for expression of the fliC or fljB flagellin genes. Two novel loci involved in negative regulation of fliC and fljB in fla mutant backgrounds were identified. One of these loci, designated the flgR locus, mapped to the flg operon at 23 min on the Salmonella linkage map. An flgR insertion mutation resulted in relief of repression of the fliC and fljB genes in all fla mutant backgrounds except for mutants in the positive regulatory loci (flhC, flhD, and fliA genes). PMID:1848842

  13. Integrated Nuclear and Conventional Theater Warfare Simulation (INWARS) Documentation. Part IV. User’s Manual Component. Volume III. EAD C2I Inputs.

    DTIC Science & Technology

    1980-02-08

    hours 0 Input Format: Integer b. Creatina Rescource Allocation Blocks The creation of a specific resource allocation block as a directive component is...is directed. 0 Range: N/A . Input Format: INT/NUC/CHM b. Creatina Employment Packages An employment package block has the structure portrayed in Figure

  14. 49 CFR 173.12 - Exceptions for shipment of waste materials.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (IBC) or a UN 11HH2 composite IBC, fitted with a polyethylene liner at least 6 mils (0.006 inches... section or in single packagings authorized for the acid in Column (8B) of the § 172.101 Hazardous... packagings authorized for the material in Column (8B) of the § 172.101 Hazardous Materials Table of this...

  15. 49 CFR 173.12 - Exceptions for shipment of waste materials.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (IBC) or a UN 11HH2 composite IBC, fitted with a polyethylene liner at least 6 mils (0.006 inches... section or in single packagings authorized for the acid in Column (8B) of the § 172.101 Hazardous... packagings authorized for the material in Column (8B) of the § 172.101 Hazardous Materials Table of this...

  16. Membrane Insertion Profiles of Peptides Probed by Molecular Dynamics Simulations

    DTIC Science & Technology

    2008-07-17

    Membrane insertion profiles of peptides probed by molecular dynamics simulations In-Chul Yeh,* Mark A. Olson,# Michael S. Lee,*#§ and Anders...a methodology based on molecular dynamics simulation techniques to probe the insertion profiles of small peptides across the membrane interface. The...profiles of peptides probed by molecular dynamics simulations 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d

  17. Gift from statistical learning: Visual statistical learning enhances memory for sequence elements and impairs memory for items that disrupt regularities.

    PubMed

    Otsuka, Sachio; Saiki, Jun

    2016-02-01

    Prior studies have shown that visual statistical learning (VSL) enhances familiarity (a type of memory) of sequences. How do statistical regularities influence the processing of each triplet element and inserted distractors that disrupt the regularity? Given that increased attention to triplets induced by VSL and inhibition of unattended triplets, we predicted that VSL would promote memory for each triplet constituent, and degrade memory for inserted stimuli. Across the first two experiments, we found that objects from structured sequences were more likely to be remembered than objects from random sequences, and that letters (Experiment 1) or objects (Experiment 2) inserted into structured sequences were less likely to be remembered than those inserted into random sequences. In the subsequent two experiments, we examined an alternative account for our results, whereby the difference in memory for inserted items between structured and random conditions is due to individuation of items within random sequences. Our findings replicated even when control letters (Experiment 3A) or objects (Experiment 3B) were presented before or after, rather than inserted into, random sequences. Our findings suggest that statistical learning enhances memory for each item in a regular set and impairs memory for items that disrupt the regularity. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. OptoZIF Drive: a 3D printed implant and assembly tool package for neural recording and optical stimulation in freely moving mice

    NASA Astrophysics Data System (ADS)

    Freedman, David S.; Schroeder, Joseph B.; Telian, Gregory I.; Zhang, Zhengyang; Sunil, Smrithi; Ritt, Jason T.

    2016-12-01

    Objective. Behavioral neuroscience studies in freely moving rodents require small, light-weight implants to facilitate neural recording and stimulation. Our goal was to develop an integrated package of 3D printed parts and assembly aids for labs to rapidly fabricate, with minimal training, an implant that combines individually positionable microelectrodes, an optical fiber, zero insertion force (ZIF-clip) headstage connection, and secondary recording electrodes, e.g. for electromyography (EMG). Approach. Starting from previous implant designs that position recording electrodes using a control screw, we developed an implant where the main drive body, protective shell, and non-metal components of the microdrives are 3D printed in parallel. We compared alternative shapes and orientations of circuit boards for electrode connection to the headstage, in terms of their size, weight, and ease of wire insertion. We iteratively refined assembly methods, and integrated additional assembly aids into the 3D printed casing. Main results. We demonstrate the effectiveness of the OptoZIF Drive by performing real time optogenetic feedback in behaving mice. A novel feature of the OptoZIF Drive is its vertical circuit board, which facilities direct ZIF-clip connection. This feature requires angled insertion of an optical fiber that still can exit the drive from the center of a ring of recording electrodes. We designed an innovative 2-part protective shell that can be installed during the implant surgery to facilitate making additional connections to the circuit board. We use this feature to show that facial EMG in mice can be used as a control signal to lock stimulation to the animal’s motion, with stable EMG signal over several months. To decrease assembly time, reduce assembly errors, and improve repeatability, we fabricate assembly aids including a drive holder, a drill guide, an implant fixture for microelectode ‘pinning’, and a gold plating fixture. Significance. The expanding capability of optogenetic tools motivates continuing development of small optoelectric devices for stimulation and recording in freely moving mice. The OptoZIF Drive is the first to natively support ZIF-clip connection to recording hardware, which further supports a decrease in implant cross-section. The integrated 3D printed package of drive components and assembly tools facilities implant construction. The easy interfacing and installation of auxiliary electrodes makes the OptoZIF Drive especially attractive for real time feedback stimulation experiments.

  19. Hearing Preservation Outcomes After Cochlear Implantation Depending on the Angle of Insertion: Indication for Electric or Electric-Acoustic Stimulation.

    PubMed

    Helbig, Silke; Adel, Youssef; Leinung, Martin; Stöver, Timo; Baumann, Uwe; Weissgerber, Tobias

    2018-06-15

    This study reviewed outcomes of hearing preservation (HP) surgery depending on the angle of insertion (AOI) in a cochlear implant (CI) patient population who used electric stimulation (ES) or combined electric-acoustic stimulation (EAS). Retrospective case review. Tertiary referral university hospital. Ninety-one patients with different degrees of preoperative low-frequency residual hearing who underwent HP surgery with a free-fitting lateral-wall electrode array (MED-EL Flex) with lengths ranging from 20.0 to 31.5 mm. Cochlear implantation using HP surgery technique and subsequent fitting with CI speech processor for ES, or combined CI and hearing aid speech processor for EAS. Individual AOI were estimated using modified Stenvers' projection. Freiburg monosyllable test in quiet (free-field presentation at 65 dB SPL) and pure-tone averages for low frequencies (125, 250, and 500 Hz; PTAlow) were evaluated during a follow-up period of 12 months after implantation. Estimated AOIs showed bimodal distribution: shallow insertion (SI) with mean AOI of 377 degrees and deep insertion (DI) with mean AOI of 608 degrees. Speech test scores after 12 months were comparable between AOI groups, however, they were significantly different between stimulation types with better scores for EAS. Only ES showed a positive correlation (r = 0.293) between speech test score and AOI. When HP was possible, both SI and DI showed significant postoperative PTAlow shifts with mean of 17.8 and 21.6 dB, respectively. These were comparable between AOI groups and no significant shifts were observed in follow-up intervals. Audiometric indication for HP and subsequent EAS is proposed up to 65 dB HL at 500 Hz, and up to 87 dB HL for HP. CI candidates can benefit from HP surgery with deep insertion when only using ES due to insufficient residual hearing. Conversely, candidates with preoperative threshold up to 65 dB HL at 500 Hz could perform significantly better with EAS which requires shallow insertion.

  20. Differences in crestal bone-to-implant contact following an under-drilling compared to an over-drilling protocol. A study in the rabbit tibia.

    PubMed

    Cohen, Omer; Ormianer, Zeev; Tal, Haim; Rothamel, Daniel; Weinreb, Miron; Moses, Ofer

    2016-12-01

    The objective of this study is to compare bone-to-implant contact (BIC) between implants inserted at high torque due to under-drilling of the crestal bone to those inserted at low torque due to over-drilling of the crestal bone. Forty implants with diameters of 3.75 mm (group A) or 3.55 mm (group B) were inserted in the proximal tibiae of NZW rabbits in two separate surgeries on day 0 or 21. Osteotomy of the crestal bone was finalized with a 3.65-mm drill. In group A, implants were inserted at torque ≥35 Ncm (under-drilling) and in group B with torque <10 Ncm (over-drilling). Implants and their surrounding bone were retrieved on day 42, thus creating 3- and 6-week observation periods, processed for non-decalcified histology and stained with toluidine blue. Crestal BIC (c-BIC) and total BIC (t-BIC) were measured. Wilcoxon test was used to evaluate differences between groups. Three weeks post-surgery, the mean c-BIC in group A was 16.3 ± 3.3 vs 31.5 ± 3.4 % in group B (P < 0.05). At 6 weeks, a similar trend was observed (group A: 28.7 ± 3.6 %; group B: 38.4 ± 4.9 %) (P > 0.05). No differences in t-BIC were noted at 3 weeks and at 6 weeks between the groups. Insertion of implants with an over-drilling protocol of the crestal aspect of the osteotomy resulted in increased short-term crestal bone-to-implant contact. Insertion of implants with a high torque following an under-drilling protocol, commonly used for immediate loading, may reduce crestal bone-to-implant contact at early healing stages.

  1. Is liver perfusion CT reproducible? A study on intra- and interobserver agreement of normal hepatic haemodynamic parameters obtained with two different software packages.

    PubMed

    Bretas, Elisa Almeida Sathler; Torres, Ulysses S; Torres, Lucas Rios; Bekhor, Daniel; Saito Filho, Celso Fernando; Racy, Douglas Jorge; Faggioni, Lorenzo; D'Ippolito, Giuseppe

    2017-10-01

    To evaluate the agreement between the measurements of perfusion CT parameters in normal livers by using two different software packages. This retrospective study was based on 78 liver perfusion CT examinations acquired for detecting suspected liver metastasis. Patients with any morphological or functional hepatic abnormalities were excluded. The final analysis included 37 patients (59.7 ± 14.9 y). Two readers (1 and 2) independently measured perfusion parameters using different software packages from two major manufacturers (A and B). Arterial perfusion (AP) and portal perfusion (PP) were determined using the dual-input vascular one-compartmental model. Inter-reader agreement for each package and intrareader agreement between both packages were assessed with intraclass correlation coefficients (ICC) and Bland-Altman statistics. Inter-reader agreement was substantial for AP using software A (ICC = 0.82) and B (ICC = 0.85-0.86), fair for PP using software A (ICC = 0.44) and fair to moderate for PP using software B (ICC = 0.56-0.77). Intrareader agreement between software A and B ranged from slight to moderate (ICC = 0.32-0.62) for readers 1 and 2 considering the AP parameters, and from fair to moderate (ICC = 0.40-0.69) for readers 1 and 2 considering the PP parameters. At best there was only moderate agreement between both software packages, resulting in some uncertainty and suboptimal reproducibility. Advances in knowledge: Software-dependent factors may contribute to variance in perfusion measurements, demanding further technical improvements. AP measurements seem to be the most reproducible parameter to be adopted when evaluating liver perfusion CT.

  2. Knock-in/Knock-out (KIKO) vectors for rapid integration of large DNA sequences, including whole metabolic pathways, onto the Escherichia coli chromosome at well-characterised loci.

    PubMed

    Sabri, Suriana; Steen, Jennifer A; Bongers, Mareike; Nielsen, Lars K; Vickers, Claudia E

    2013-06-24

    Metabolic engineering projects often require integration of multiple genes in order to control the desired phenotype. However, this often requires iterative rounds of engineering because many current insertion approaches are limited by the size of the DNA that can be transferred onto the chromosome. Consequently, construction of highly engineered strains is very time-consuming. A lack of well-characterised insertion loci is also problematic. A series of knock-in/knock-out (KIKO) vectors was constructed for integration of large DNA sequences onto the E. coli chromosome at well-defined loci. The KIKO plasmids target three nonessential genes/operons as insertion sites: arsB (an arsenite transporter); lacZ (β-galactosidase); and rbsA-rbsR (a ribose metabolism operon). Two homologous 'arms' target each insertion locus; insertion is mediated by λ Red recombinase through these arms. Between the arms is a multiple cloning site for the introduction of exogenous sequences and an antibiotic resistance marker (either chloramphenicol or kanamycin) for selection of positive recombinants. The resistance marker can subsequently be removed by flippase-mediated recombination. The insertion cassette is flanked by hairpin loops to isolate it from the effects of external transcription at the integration locus. To characterize each target locus, a xylanase reporter gene (xynA) was integrated onto the chromosomes of E. coli strains W and K-12 using the KIKO vectors. Expression levels varied between loci, with the arsB locus consistently showing the highest level of expression. To demonstrate the simultaneous use of all three loci in one strain, xynA, green fluorescent protein (gfp) and a sucrose catabolic operon (cscAKB) were introduced into lacZ, arsB and rbsAR respectively, and shown to be functional. The KIKO plasmids are a useful tool for efficient integration of large DNA fragments (including multiple genes and pathways) into E. coli. Chromosomal insertion provides stable expression without the need for continuous antibiotic selection. Three non-essential loci have been characterised as insertion loci; combinatorial insertion at all three loci can be performed in one strain. The largest insertion at a single site described here was 5.4 kb; we have used this method in other studies to insert a total of 7.3 kb at one locus and 11.3 kb across two loci. These vectors are particularly useful for integration of multigene cassettes for metabolic engineering applications.

  3. The Application of Coconut Fiber as Dissipative Silencer

    NASA Astrophysics Data System (ADS)

    Madlan, M. A.; Ghazali, M. I.; Zaman, I.; Kasron, M. Z.; Ying, T. C.

    2017-01-01

    Heat ventilation air conditioning system (HVAC) is one of the ducting systems that broadly applied in the building. There are HVAC silencers in the market, however the sound absorptive material commonly used is mineral wool. In this research study, a sound absorptive material made of coconut fiber was tested to identify its performance as a potential replacement of green material for ducting silencer. The experiment was carried out in a testing apparatus that follows the BS EN ISO 11691:2009 standard. Different configurations of sound absorptive material and contents of coconut fiber were investigated in the study. The trend of insertion loss at 1/3 octave frequency was identified where at frequency below 3000Hz, the insertion loss of dissipative silencer is observed high at certain frequency with a very narrow range. At 3000Hz, the insertion loss of 4dB to 6dB is constant until 4000Hz and drops until 5000Hz before it increases again steadily up to 13dB at 10000Hz. A similar trend was observed for different configuration of sound absorptive material. Despite the configuration different, the outcome shows that the insertion loss is increasing with higher content of coconut fiber.

  4. [Effects of packaging forms on the stability of vitamin B1 and vitamin C in TPN admixtures].

    PubMed

    Hashimoto, Daisuke; Iwahara, Ryosei; Sato, Hideki

    2010-12-01

    In order to reduce a microbial contamination and needle stick injuries that are associated with a mixing procedure in home parentera nutrition(HPN), nutrition(TPN)solution bags pre-mixed with trace elements may be provided in a form of outer packaging. On the other hand, a packaging form used to enclose the TPN bag after admixture may significantly affect the stability of vitamins. With a focus on possible decrease in vitamin B1 and C content, we investigated the effects of the packaging form. As a result, the TPN bag, which is packed in a light-resistant outer wrap of oxygen-barrier film with an oxygen absorbent under reduced pressure, suppressed a decrease in vitamin content most. However, the decrease in vitamin C content was observed when there was a long time-lag between a preparation and a packaging. We thought it was desirable to pack the TPN bag promptly after the preparation.

  5. 40 CFR 63.822 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... § 63.827(c). A material safety data sheet (MSDS) may serve as a CPDS provided the MSDS meets the data requirements of § 63.827(b) and (c). The purpose of the CPDS is to assist the owner or operator in... packaging means any package or part of a package the shape of which can be readily changed. Flexible...

  6. 49 CFR 173.472 - Requirements for exporting DOT Specification Type B and fissile packages.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... or (202) 366-3650, or by electronic mail (e-mail) to “[email protected]” Each request is considered in... the package identification marking indicated in the U.S. Competent Authority Certificate. (e) Before... into or through which the package will be transported, unless the offeror has documentary evidence that...

  7. The B2 Alternatively Spliced Isoform of Nonmuscle Myosin II-B Lacks Actin-activated MgATPase Activity and In Vitro Motility

    PubMed Central

    Kim, Kye-Young; Kawamoto, Sachiyo; Bao, Jianjun; Sellers, James R.; Adelstein, Robert S.

    2008-01-01

    We report the initial biochemical characterization of an alternatively spliced isoform of nonmuscle heavy meromyosin (HMM) II-B2 and compare it with HMM II-B0, the non-spliced isoform. HMM II-B2 is the HMM derivative of an alternatively spliced isoform of endogenous nonmuscle myosin (NM) II-B, which has 21-amino acids inserted into loop 2, near the actin-binding region. NM II-B2 is expressed in the Purkinje cells of the cerebellum as well as in other neuronal cells (Ma et al., Mol. Biol. Cell 15 (2006) 2138-2149). In contrast to any of the previously described isoforms of NM II (II-A, II-B0, II-B1, II-C0 and II-C1) or to smooth muscle myosin, the actin-activated MgATPase activity of HMM II-B2 is not significantly increased from a low, basal level by phosphorylation of the 20 kDa myosin light chain (MLC-20). Moreover, although HMM II-B2 can bind to actin in the absence of ATP and is released in its presence, it cannot propel actin in the sliding actin filament assay following MLC-20 phosphorylation. Unlike HMM II-B2, the actin-activated MgATPase activity of a chimeric HMM with the 21-amino acids II-B2 sequence inserted into the homologous location in the heavy chain of HMM II-C is increased following MLC-20 phosphorylation. This indicates that the effect of the II-B2 insert is myosin heavy chain specific. PMID:18060863

  8. Retrotransposons of the Tnt1B family are mobile in Nicotiana plumbaginifolia and can induce alternative splicing of the host gene upon insertion.

    PubMed

    Leprinc, A S; Grandbastien, M A; Christian, M

    2001-11-01

    Active retrotransposons have been identified in Nicotiana plumbaginifolia by their ability to disrupt the nitrate reductase gene in chlorate-resistant mutants selected from protoplast-derived cultures. In mutants E23 and F97, two independent insertions of Tnp2, a new retrotransposon closely related to the tobacco Tnt1 elements, were detected in the nitrate reductase gene. These two Tnp2 elements are members of the Tnt1B subfamily which shows that Tnt1B elements can be active and mutagenic in the N. plumbaginifolia genome. Furthermore, these results suggest that Tnt1B is the most active family of Tntl elements in N. plumbaginifolia, whereas in tobacco only members of the Tnt1A subfamily were found inserted in the nitrate reductase gene. The transcriptional regulations of Tnp2 and Tnt1A elements are most probably different due to non-conserved U3 regions. Our results thus support the hypothesis that different Nicotiana species contain different active Tntl subfamilies and that only one active Tntl subfamily might be maintained in each of these species. The Tnp2 insertion found in the F97 mutant was found to be spliced out of the nitrate reductase mRNA by activation of cryptic donor and acceptor sites in the nitrate reductase and the Tnp2 sequences respectively.

  9. Experimental investigation of the noise reduction of supersonic exhaust jets with fluidic inserts

    NASA Astrophysics Data System (ADS)

    Powers, Russell William Walter

    The noise produced by the supersonic, high temperature jets that exhaust from military aircraft is becoming a hazard to naval personnel and a disturbance to communities near military bases. Methods to reduce the noise produced from these jets in a practical full-scale environment are difficult. The development and analysis of distributed nozzle blowing for the reduction of radiated noise from supersonic jets is described. Model scale experiments of jets that simulate the exhaust jets from typical low-bypass ratio military jet aircraft engines during takeoff are performed. Fluidic inserts are created that use distributed blowing in the divergent section of the nozzle to simulate mechanical, hardwall corrugations, while having the advantage of being an active control method. This research focuses on model scale experiments to better understand the fluidic insert noise reduction method. Distributed blowing within the divergent section of the military-style convergent divergent nozzle alters the shock structure of the jet in addition to creating streamwise vorticity for the reduction of mixing noise. Enhancements to the fluidic insert design have been performed along with experiments over a large number of injection parameters and core jet conditions. Primarily military-style round nozzles have been used, with preliminary measurements of hardwall corrugations and fluidic inserts in rectangular nozzle geometries also performed. It has been shown that the noise reduction of the fluidic inserts is most heavily dependent upon the momentum flux ratio between the injector and core jet. Maximum reductions of approximately 5.5 dB OASPL have been observed with practical mass flow rates and injection pressures. The first measurements with fluidic inserts in the presence of a forward flight stream have been performed. Optimal noise reduction occurs at similar injector parameters in the presence of forward flight. Fluidic inserts in the presence of a forward flight stream were observed to reduce the peak mixing noise below the already reduced levels by nearly 4 dB OASP and the broadband shock-associated noise by nearly 3 dB OASP. Unsteady velocity measurements are used to complement acoustic results of jets with fluidic inserts. Measured axial turbulence intensities and mean axial velocity are examined to illuminate the differences in the flow field from jets with fluidic inserts. Comparisons of laser Doppler measurements with RANS CFD simulations are shown with good agreement. Analysis of the effect of spatial turbulence on the measured quantities is performed. Experimental model scale measurements of jets with and without fluidic inserts over a simulated carrier deck are presented. The model carrier environment consists of a ground plane of adjustable distance below the jet, and a simulated jet blast deflector similar to those found in practice. Measurements are performed with far-field microphones, near-field microphones, and unsteady pressure sensors. The constructive and destructive interference that results from the interaction of the direct and reflected sound waves is observed and compared with results from free jets. The noise reduction of fluidic inserts in a realistic carrier deck environment with steering of the "quiet planes" is examined. The overall sound pressure level in heat-simulated jets is reduced by 3-5 dB depending on the specific angle and ground plane height. Jets impinging upon a modeled jet blast deflector are tested in addition to jets solely in the presence of the carrier deck. Observed modifications to the acoustic field from the presence of the jet blast deflector include downstream acoustic shielding and low frequency augmentation. The region of maximum noise radiation for heat-simulated jets from nozzles with fluidic inserts impinging on the jet blast deflector is reduced in overall sound pressure level by 4-7 dB. This region includes areas where aircraft carrier personnel are located. iv.

  10. Doping test results dependent on genotype of uridine diphospho-glucuronosyl transferase 2B17, the major enzyme for testosterone glucuronidation.

    PubMed

    Schulze, Jenny Jakobsson; Lundmark, Jonas; Garle, Mats; Skilving, Ilona; Ekström, Lena; Rane, Anders

    2008-07-01

    Testosterone abuse is conventionally assessed by the urinary testosterone/epitestosterone (T/E) ratio, levels above 4.0 being considered suspicious. The large variation in testosterone glucuronide (TG) excretion and its strong association with a deletion polymorphism in the uridine diphospho-glucuronosyl transferase (UGT) 2B17 gene challenge the accuracy of the T/E ratio test. Our objective was to investigate whether genotype-based cutoff values will improve the sensitivity and specificity of the test. This was an open three-armed comparative study. A total of 55 healthy male volunteers with either two, one, or no allele [insertion/insertion, insertion/deletion, or deletion/deletion (del/del)] of the UGT2B17 gene was included in the study. A single im dose of 500 mg testosterone enanthate was administered. Urinary excretion of TG after dose and the T/E ratio during 15 d were calculated. The degree and rate of increase in the TG excretion rate were highly dependent on the UGT2B17 genotype with a 20-fold higher average maximum increase in the insertion/insertion group compared with the del/del group. Of the del/del subjects, 40% never reached the T/E ratio of 4.0 on any of the 15 d after the dose. When differentiated cutoff levels for the del/del (1.0) and the other genotypes (6.0) were applied, the sensitivity increased substantially for the del/del group, and false positives in the other genotypes were eliminated. Consideration of the genetic variation in disposition of androgens will improve the sensitivity and specificity of the testosterone doping test. This is of interest not only for combating androgen doping in sports, but also for detecting and preventing androgen abuse in society.

  11. Progress in performance enhancement methods for capacitive silicon resonators

    NASA Astrophysics Data System (ADS)

    Van Toan, Nguyen; Ono, Takahito

    2017-11-01

    In this paper, we review the progress in recent studies on the performance enhancement methods for capacitive silicon resonators. We provide information on various fabrication technologies and design considerations that can be employed to improve the performance of capacitive silicon resonators, including low motional resistance, small insertion loss, and high quality factor (Q). This paper contains an overview of device structures and working principles, fabrication technologies consisting of hermetic packaging, deep reactive-ion etching and neutral beam etching, and design considerations including mechanically coupled, movable electrode structures and piezoresistive heat engines.

  12. Apollo 17

    NASA Technical Reports Server (NTRS)

    Garrett, David

    1972-01-01

    This is the Press Kit that was given to the various media outlets that were interested in covering the Apollo 17 mission. It includes information about the moon, lunar science, concentrating on the planned mission. The kit includes information about the flight, and the trajectory, planned orbit insertion maneuvers, the extravehicular mission events, a comparison with the Apollo 16, a map of the lunar surface, and the surface activity, information about the Taurus-Littrow landing site, the planned science experiments, the power source for the experiment package and diagrams of some of the instrumentation that was used to perform the experiments.

  13. Superlattice structure modeling and simulation of High Electron Mobility Transistor for improved performance

    NASA Astrophysics Data System (ADS)

    Munusami, Ravindiran; Yakkala, Bhaskar Rao; Prabhakar, Shankar

    2013-12-01

    Magnetic tunnel junction were made by inserting the magnetic materials between the source, channel and the drain of the High Electron Mobility Transistor (HEMT) to enhance the performance. Material studio software package was used to design the superlattice layers. Different cases were analyzed to optimize the performance of the device by placing the magnetic material at different positions of the device. Simulation results based on conductivity reveals that the device has a very good electron transport due to the magnetic materials and will amplify very low frequency signals.

  14. The Myosin IXb Motor Activity Targets the Myosin IXb RhoGAP Domain as Cargo to Sites of Actin Polymerization

    PubMed Central

    van den Boom, Frank; Düssmann, Heiko; Uhlenbrock, Katharina; Abouhamed, Marouan

    2007-01-01

    Myosin IXb (Myo9b) is a single-headed processive myosin that exhibits Rho GTPase-activating protein (RhoGAP) activity in its tail region. Using live cell imaging, we determined that Myo9b is recruited to extending lamellipodia, ruffles, and filopodia, the regions of active actin polymerization. A functional motor domain was both necessary and sufficient for targeting Myo9b to these regions. The head domains of class IX myosins comprise a large insertion in loop2. Deletion of the large Myo9b head loop 2 insertion abrogated the enrichment in extending lamellipodia and ruffles, but enhanced significantly the enrichment at the tips of filopodia and retraction fibers. The enrichment in the tips of filopodia and retraction fibers depended on four lysine residues C-terminal to the loop 2 insertion and the tail region. Fluorescence recovery after photobleaching and photoactivation experiments in lamellipodia revealed that the dynamics of Myo9b was comparable to that of actin. The exchange rates depended on the Myo9b motor region and motor activity, and they were also dependent on the turnover of F-actin. These results demonstrate that Myo9b functions as a motorized RhoGAP molecule in regions of actin polymerization and identify Myo9b head sequences important for in vivo motor properties. PMID:17314409

  15. Cooperative heteroassembly of the adenoviral L4-22K and IVa2 proteins onto the viral packaging sequence DNA.

    PubMed

    Yang, Teng-Chieh; Maluf, Nasib Karl

    2012-02-21

    Human adenovirus (Ad) is an icosahedral, double-stranded DNA virus. Viral DNA packaging refers to the process whereby the viral genome becomes encapsulated by the viral particle. In Ad, activation of the DNA packaging reaction requires at least three viral components: the IVa2 and L4-22K proteins and a section of DNA within the viral genome, called the packaging sequence. Previous studies have shown that the IVa2 and L4-22K proteins specifically bind to conserved elements within the packaging sequence and that these interactions are absolutely required for the observation of DNA packaging. However, the equilibrium mechanism for assembly of IVa2 and L4-22K onto the packaging sequence has not been determined. Here we characterize the assembly of the IVa2 and L4-22K proteins onto truncated packaging sequence DNA by analytical sedimentation velocity and equilibrium methods. At limiting concentrations of L4-22K, we observe a species with two IVa2 monomers and one L4-22K monomer bound to the DNA. In this species, the L4-22K monomer is promoting positive cooperative interactions between the two bound IVa2 monomers. As L4-22K levels are increased, we observe a species with one IVa2 monomer and three L4-22K monomers bound to the DNA. To explain this result, we propose a model in which L4-22K self-assembly on the DNA competes with IVa2 for positive heterocooperative interactions, destabilizing binding of the second IVa2 monomer. Thus, we propose that L4-22K levels control the extent of cooperativity observed between adjacently bound IVa2 monomers. We have also determined the hydrodynamic properties of all observed stoichiometric species; we observe that species with three L4-22K monomers bound have more extended conformations than species with a single L4-22K bound. We suggest this might reflect a molecular switch that controls insertion of the viral DNA into the capsid.

  16. Safety analysis report for packaging (onsite) multicanister overpack cask

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, W.S.

    1997-07-14

    This safety analysis report for packaging (SARP) documents the safety of shipments of irradiated fuel elements in the MUlticanister Overpack (MCO) and MCO Cask for a highway route controlled quantity, Type B fissile package. This SARP evaluates the package during transfers of (1) water-filled MCOs from the K Basins to the Cold Vacuum Drying Facility (CVDF) and (2) sealed and cold vacuum dried MCOs from the CVDF in the 100 K Area to the Canister Storage Building in the 200 East Area.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrell, P.C.

    This SARP describes the RTG Transportation System Package, a Type B(U) packaging system that is used to transport an RTG or similar payload. The payload, which is included in this SARP, is a generic, enveloping payload that specifically encompasses the General Purpose Heat Source (GPHS) RTG payload. The package consists of two independent containment systems mounted on a shock isolation transport skid and transported within an exclusive-use trailer.

  18. Skills Analysis. Workshop Package on Skills Analysis, Skills Audit and Training Needs Analysis.

    ERIC Educational Resources Information Center

    Hayton, Geoff; And Others

    This four-part package is designed to assist Australian workshop leaders running 2-day workshops on skills analysis, skills audit, and training needs analysis. Part A contains information on how to use the package and a list of workshop aims. Parts B, C, and D consist, respectively, of the workshop leader's guide; overhead transparency sheets and…

  19. 49 CFR 172.202 - Description of hazardous material on shipping papers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Bulk packages, provided some indication of the total quantity is shown, for example, “1 cargo tank” or... cylinders.” (C) Packages containing only residue. (6) For transportation by aircraft, the total net mass per package, must be shown unless a gross mass is indicated in Columns (9A) or (9B) of the § 172.101 table in...

  20. 49 CFR 172.202 - Description of hazardous material on shipping papers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Bulk packages, provided some indication of the total quantity is shown, for example, “1 cargo tank” or... cylinders.” (C) Packages containing only residue. (6) For transportation by aircraft, the total net mass per package, must be shown unless a gross mass is indicated in Columns (9A) or (9B) of the § 172.101 table in...

  1. 49 CFR 172.202 - Description of hazardous material on shipping papers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Bulk packages, provided some indication of the total quantity is shown, for example, “1 cargo tank” or... cylinders.” (C) Packages containing only residue. (6) For transportation by aircraft, the total net mass per package, must be shown unless a gross mass is indicated in Columns (9A) or (9B) of the § 172.101 table in...

  2. 48 CFR 2011.104-70 - NRC Clauses.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Technical Reports, when deliverables include a technical report. (b) The contracting officer shall insert the clause at 2052.211-71 Technical Progress Report, in all solicitations and contracts except— (1...) The contracting officer shall insert the clause at 2052.211-72 Financial Status Report, in applicable...

  3. 48 CFR 2011.104-70 - NRC Clauses.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Technical Reports, when deliverables include a technical report. (b) The contracting officer shall insert the clause at 2052.211-71 Technical Progress Report, in all solicitations and contracts except— (1...) The contracting officer shall insert the clause at 2052.211-72 Financial Status Report, in applicable...

  4. 48 CFR 2011.104-70 - NRC Clauses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Technical Reports, when deliverables include a technical report. (b) The contracting officer shall insert the clause at 2052.211-71 Technical Progress Report, in all solicitations and contracts except— (1...) The contracting officer shall insert the clause at 2052.211-72 Financial Status Report, in applicable...

  5. 48 CFR 2011.104-70 - NRC Clauses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Technical Reports, when deliverables include a technical report. (b) The contracting officer shall insert the clause at 2052.211-71 Technical Progress Report, in all solicitations and contracts except— (1...) The contracting officer shall insert the clause at 2052.211-72 Financial Status Report, in applicable...

  6. 48 CFR 2011.104-70 - NRC Clauses.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Technical Reports, when deliverables include a technical report. (b) The contracting officer shall insert the clause at 2052.211-71 Technical Progress Report, in all solicitations and contracts except— (1...) The contracting officer shall insert the clause at 2052.211-72 Financial Status Report, in applicable...

  7. Photonic lantern with multimode fibers embedded

    NASA Astrophysics Data System (ADS)

    Yu, Hai-Jiao; Yan, Qi; Huang, Zong-Jun; Tian, He; Jiang, Yu; Liu, Yong-Jun; Zhang, Jian-Zhong; Sun, Wei-Min

    2014-08-01

    A photonic lantern is studied which is formed by seven multimode fibers inserted into a pure silica capillary tube. The core of the tapered end has a uniform refractive index because the polymer claddings are removed before the fibers are inserted. Consequently, the light distribution is also uniform. Two theories describing a slowly varying waveguide and multimode coupling are used to analyze the photonic lantern. The transmission loss decreases as the length of the tapered part increases. For a device with a taper length of 3.4 cm, the loss is about 1.06 dB on average for light propagating through the taper from an inserted fiber to the tapered end and 0.99 dB in the reverse direction. For a device with a taper length of 0.7 cm, the two loss values are 2.63 dB and 2.53 dB, respectively. The results show that it is possible to achieve a uniform light distribution with the tapered end and a low-loss transmission in the device if parameters related to the lantern are reasonably defined.

  8. Highly Compact Circulators in Square-Lattice Photonic Crystal Waveguides

    PubMed Central

    Jin, Xin; Ouyang, Zhengbiao; Wang, Qiong; Lin, Mi; Wen, Guohua; Wang, Jingjing

    2014-01-01

    We propose, demonstrate and investigate highly compact circulators with ultra-low insertion loss in square-lattice- square-rod-photonic-crystal waveguides. Only a single magneto- optical square rod is required to be inserted into the cross center of waveguides, making the structure very compact and ultra efficient. The square rods around the center defect rod are replaced by several right-angled-triangle rods, reducing the insertion loss further and promoting the isolations as well. By choosing a linear-dispersion region and considering the mode patterns in the square magneto-optical rod, the operating mechanism of the circulator is analyzed. By applying the finite-element method together with the Nelder-Mead optimization method, an extremely low insertion loss of 0.02 dB for the transmitted wave and ultra high isolation of 46 dB∼48 dB for the isolated port are obtained. The idea presented can be applied to build circulators in different wavebands, e.g., microwave or Tera-Hertz. PMID:25415417

  9. Highly compact circulators in square-lattice photonic crystal waveguides.

    PubMed

    Jin, Xin; Ouyang, Zhengbiao; Wang, Qiong; Lin, Mi; Wen, Guohua; Wang, Jingjing

    2014-01-01

    We propose, demonstrate and investigate highly compact circulators with ultra-low insertion loss in square-lattice- square-rod-photonic-crystal waveguides. Only a single magneto- optical square rod is required to be inserted into the cross center of waveguides, making the structure very compact and ultra efficient. The square rods around the center defect rod are replaced by several right-angled-triangle rods, reducing the insertion loss further and promoting the isolations as well. By choosing a linear-dispersion region and considering the mode patterns in the square magneto-optical rod, the operating mechanism of the circulator is analyzed. By applying the finite-element method together with the Nelder-Mead optimization method, an extremely low insertion loss of 0.02 dB for the transmitted wave and ultra high isolation of 46 dB∼48 dB for the isolated port are obtained. The idea presented can be applied to build circulators in different wavebands, e.g., microwave or Tera-Hertz.

  10. Results for diffusion-weighted imaging with a fourth-channel gradient insert.

    PubMed

    Feldman, Rebecca E; Scholl, Timothy J; Alford, Jamu K; Handler, William B; Harris, Chad T; Chronik, Blaine A

    2011-12-01

    Diffusion-weighted imaging suffers from motion artifacts and relatively low signal quality due to the long echo times required to permit the diffusion encoding. We investigated the inclusion of a noncylindrical fourth gradient coil, dedicated entirely to diffusion encoding, into the imaging system. Standard three-axis whole body gradients were used during image acquisition, but we designed and constructed an insert coil to perform diffusion encodings. We imaged three phantoms on a 3-T system with a range of diffusion coefficients. Using the insert gradient, we were able to encode b values of greater than 1300 s/mm(2) with an echo time of just 83 ms. Images obtained using the insert gradient had higher signal to noise ratios than those obtained using the whole body gradient: at 500 s/mm(2) there was a 18% improvement in signal to noise ratio, at 1000 s/mm(2) there was a 39% improvement in signal to noise ratio, and at 1350 s/mm(2) there was a 56% improvement in signal to noise ratio. Using the insert gradient, we were capable of doing diffusion encoding at high b values by using relatively short echo times. Copyright © 2011 Wiley Periodicals, Inc.

  11. RH Packaging Program Guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Washington TRU Solutions LLC

    The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: "...each package must be prepared for shipment and operated in accordance with the proceduresmore » described in Chapter 7.0, Operating Procedures, of the application." It further states: "...each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M&O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with 10 Code of Federal Regulations (CFR) §71.8, "Deliberate Misconduct." Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, "Packaging and Transportation of Radioactive Material," certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, "Reporting of Defects and Noncompliance," regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are conducted. This document details the instructions to be followed to operate, maintain, and test the RH-TRU 72-B packaging. This Program Guidance standardizes instructions for all users. Users shall follow these instructions or equivalent approved instructions. Following these instructions assures that operations meet the requirements of the SARP.« less

  12. Altered Viral Replication and Cell Responses by Inserting MicroRNA Recognition Element into PB1 in Pandemic Influenza A Virus (H1N1) 2009

    PubMed Central

    Shen, Xiaoyue; Sun, Wenkui; Shi, Yi; Xing, Zheng; Su, Xin

    2015-01-01

    Objective. MicroRNAs (miRNAs) are endogenous noncoding RNAs that spatiotemporally modulate mRNAs in a posttranscriptional manner. Engineering mutant viruses by inserting cell-specific miRNA recognition element (MRE) into viral genome may alter viral infectivity and host responses in vital tissues and organs infected with pandemic influenza A virus (H1N1) 2009 (H1N1pdm). Methods. In this study, we employed reverse genetics approach to generate a recombinant H1N1pdm with a cell-specific miRNA target sequence inserted into its PB1 genomic segment to investigate whether miRNAs are able to suppress H1N1pdm replication. We inserted an MRE of microRNA-let-7b (miR-let-7b) into the open reading frame of PB1 to test the feasibility of creating a cell-restricted H1N1pdm virus since let-7b is abundant in human bronchial epithelial cells. Results. miR-let-7b is rich in human bronchial epithelial cells (HBE). Incorporation of the miR-let-7b-MRE confers upon the recombinant H1N1pdm virus susceptibility to miR-let-7b targeting, suggesting that the H1N1pdm and influenza A viruses can be engineered to exert the desired replication restrictive effect and decrease infectivity in vital tissues and organs. Conclusions. This approach provides an additional layer of biosafety and thus has great potential for the application in the rational development of safer and more effective influenza viral vaccines. PMID:25788763

  13. Rare Examples of Fe(IV) Alkyl-Imide Migratory Insertions: Impact of Fe-C Covalency in (Me2IPr)Fe(═NAd)R2 (R = neoPe, 1-nor).

    PubMed

    Jacobs, Brian P; Wolczanski, Peter T; Jiang, Quan; Cundari, Thomas R; MacMillan, Samantha N

    2017-09-06

    The iron(IV) imide complexes, (Me 2 IPr)-R 2 Fe=NAd (R = neo Pe (3a), 1-nor (3b)) undergo migratory insertion to iron(II) amides (Me 2 IPr)RFe{NR(Ad)} (R = neo Pe (4a), 1-nor (4b)) without evidence of imidyl or free nitrene character. By increasing the field strength about iron, odd-electron reactivity was circumvented via increased covalency.

  14. Finite Ground Coplanar Waveguide Shunt MEMS Switches for Switched Line Phase Shifters

    NASA Technical Reports Server (NTRS)

    Ponchak, George E.; Simons, Rainee N.; Scardelletti, Maximillian; Varaljay, Nicholas C.

    2000-01-01

    Switches with low insertion loss and high isolation are required for switched line phase shifters and the transmit/receive switch at the front end of communication systems. A Finite Ground Coplanar (FGC) waveguide capacitive, shunt MEMS switch has been implemented on high resistivity Si. The switch has demonstrated an insertion loss of less than 0.3 dB and a return loss greater than 15 dB from 10 to 20, GHz. The switch design, fabrication, and characteristics are presented.

  15. Mini-Tn7 Insertion in Bacteria With Multiple glmS-Linked attTn7 Sites: Example Burkholderia Mallei ATCC 23344

    DTIC Science & Technology

    2006-06-27

    INTRODUCTION Burkholderia mallei is the etiological agent of glanders and a highly evolved obligate zoonotic mammalian pathogen that naturally affects horses...mini-Tn7 insertion in bacteria with multiple glmS-linked attTn7 sites: example Burkholderia mallei ATCC 23344 Kyoung-Hee Choi1, David DeShazer2... glanders is a rare disease, B. mallei has received renewed attention because of its listing as a category B agent by the Centers for Disease Control

  16. Performance oriented packaging testing of nine Mk 3 Mod 0 signal containers in PPP-B-621 wood box for packing group II solid hazardous materials. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libbert, K.J.

    1992-10-01

    A PPP-B-621 wood box containing nine Mk 3 Mod 0 Signal containers was tested for conformance to Performance Oriented Packaging criteria established by Code of Federal Regulations Title 49 CFR. The container was tested with a gross weight of 123.3 pounds (56 kilograms) and met all requirements.

  17. Nicotinamide dependence of uropathogenic Escherichia coli UTI89 and application of nadB as a neutral insertion site.

    PubMed

    Li, Zhaoli; Bouckaert, Julie; Deboeck, Francine; De Greve, Henri; Hernalsteens, Jean-Pierre

    2012-03-01

    NAD and NADP are ubiquitous in the metabolism of Escherichia coli K-12. NAD auxotrophy can be rendered by mutation in any of the three genes nadB, nadA and nadC. The nadB and nadA genes were defined as antivirulence loci in Shigella spp., as a mutation (mainly in nadB) disrupting the synthesis of quinolinate is required for virulence. Uropathogenic E. coli (UPEC) isolates from acute cystitis patients, exhibiting nicotinamide auxotrophy, were of serotype O18 : K1 : H7. E. coli UTI89, the model uropathogenic and O18 : K1 : H7 strain, requires nicotinamide or quinolinate for growth. A mutation in the nadB gene, encoding L-aspartate oxidase, was shown to be responsible for the nicotinamide requirement of UTI89. This was further confirmed by complementation of UTI89 with a recombinant plasmid harbouring the nadB gene of E. coli K-12. An Ala28Val point mutant of the recombinant plasmid failed to support the growth of UTI89 in minimal medium. This proves that the Ala28Val mutation in the NadB gene of UTI89 completely impedes de novo synthesis of nicotinamide. In spontaneous prototrophic revertants of UTI89, the nadB gene has a Val28Ala mutation. Both analyses implicate that the nicotinamide auxotrophy of UTI89 is caused by a single Ala28Val mutation in NadB. We showed that the same mutation is also present in other NAD auxotrophic E. coli O18 strains. No significant differences were observed between the virulence of isogenic NAD auxotrophic and prototrophic strains in the murine ascending urinary tract infection model. Considering these data, we applied the nadB locus as a neutral site for DNA insertions in the bacterial chromosome. We successfully restored the parental phenotype of a fimH mutant by inserting fimH, with a synthetic em7 promoter, into the nadB gene. This neutral insertion site is of significance for further research on the pathogenicity of UPEC.

  18. LED backlight system with fiber-optic red, green, blue to white color combiner

    NASA Astrophysics Data System (ADS)

    Kim, Hye R.; Jeong, Yunsong; Lee, Jhang-Woo; Oh, Kyunghwan

    2006-09-01

    As an application in the backlight system of small LCD display, we realized a pure white light source by mixing red, green, blue (RGB) lights using a 3 X 3 Hard Plastic Cladding Fiber (HPCF) coupler. We also proposed the 0.44 inch LED backlight system with these fiber-optic pure white sources and characterized its illumination characteristics. Using optimized fusion-tapering technique, we fabricated HPCF coupler which combines three input lights over the circularly formed waist. HPCF has the core diameter of 200 μm and clad diameter of 230 μm. The fabricated 3 X 3 HPCF coupler has the perfect uniformity of about 0.3 dB, low insertion loss of 5.5 dB, and low excess loss of 0.8 dB, which shows excellent uniform power splitting ratio. In order to improve the transmission performance, The RGB chip LEDs were butt-coupled directly to the ferruled input ports of the coupler and packaged by TO46-can type. In the produced white color by HPCF coupler, the photometric brightness at the circular endface of outputs of HPCF coupler was in a rage of 10062 ~ 10094 cd/m2. The fiber optic white color combiner provides tunable white sources excluding heat source and having thickness of 200 μm. We also proposed a 0.44 inch LED backlight system with these fiber-optic pure white sources. With the proposed device, we obtain the improved uniformity in luminance distribution and wide color gamut by using the white light mixing red, green and blue lights.

  19. 48 CFR 2452.216-74 - Distribution of award fee.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: Evaluation Period: [insert time period] Available Award Fee: [insert dollar amount] (b) In the event of...-rata distribution associated with evaluation period activities or events as determined by the Fee... 2416.406(e)(3), add paragraph (c): (c) The contract clauses required for cost-reimbursement contracts...

  20. 48 CFR 2452.216-74 - Distribution of award fee.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: Evaluation Period: [insert time period] Available Award Fee: [insert dollar amount] (b) In the event of...-rata distribution associated with evaluation period activities or events as determined by the Fee... 2416.406(e)(3), add paragraph (c): (c) The contract clauses required for cost-reimbursement contracts...

  1. 48 CFR 2452.216-74 - Distribution of award fee.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: Evaluation Period: [insert time period] Available Award Fee: [insert dollar amount] (b) In the event of...-rata distribution associated with evaluation period activities or events as determined by the Fee... 2416.406(e)(3), add paragraph (c): (c) The contract clauses required for cost-reimbursement contracts...

  2. 48 CFR 2452.216-74 - Distribution of award fee.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: Evaluation Period: [insert time period] Available Award Fee: [insert dollar amount] (b) In the event of...-rata distribution associated with evaluation period activities or events as determined by the Fee... 2416.406(e)(3), add paragraph (c): (c) The contract clauses required for cost-reimbursement contracts...

  3. 48 CFR 2452.216-74 - Distribution of award fee.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: Evaluation Period: [insert time period] Available Award Fee: [insert dollar amount] (b) In the event of...-rata distribution associated with evaluation period activities or events as determined by the Fee... 2416.406(e)(3), add paragraph (c): (c) The contract clauses required for cost-reimbursement contracts...

  4. 49 CFR 178.915 - General Large Packaging standards.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... intended for solid hazardous materials must be sift-proof and water-resistant. (b) All service equipment... times. (e) Large Packaging design types must be constructed in such a way as to be bottom-lifted or top...

  5. 49 CFR 178.915 - General Large Packaging standards.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... intended for solid hazardous materials must be sift-proof and water-resistant. (b) All service equipment... times. (e) Large Packaging design types must be constructed in such a way as to be bottom-lifted or top...

  6. 49 CFR 178.915 - General Large Packaging standards.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... intended for solid hazardous materials must be sift-proof and water-resistant. (b) All service equipment... times. (e) Large Packaging design types must be constructed in such a way as to be bottom-lifted or top...

  7. Effect of Footprint Preparation on Tendon-to-Bone Healing: A Histologic and Biomechanical Study in a Rat Rotator Cuff Repair Model.

    PubMed

    Nakagawa, Haruhiko; Morihara, Toru; Fujiwara, Hiroyoshi; Kabuto, Yukichi; Sukenari, Tsuyoshi; Kida, Yoshikazu; Furukawa, Ryuhei; Arai, Yuji; Matsuda, Ken-Ichi; Kawata, Mitsuhiro; Tanaka, Masaki; Kubo, Toshikazu

    2017-08-01

    To compare the histologic and biomechanical effects of 3 different footprint preparations for repair of tendon-to-bone insertions and to assess the behavior of bone marrow-derived cells in each method of insertion repair. We randomized 81 male Sprague-Dawley rats and green fluorescent protein-bone marrow chimeric rats into 3 groups. In group A, we performed rotator cuff repair after separating the supraspinatus tendon from the greater tuberosity and removing the residual tendon tissue. In group B, we also drilled 3 holes into the footprint. The native fibrocartilage was preserved in groups A and B. In group C, we excavated the footprint until the cancellous bone was exposed. Histologic repair of the tendon-to-bone insertion, behavior of the bone marrow-derived cells, and ultimate force to failure were examined postoperatively. The areas of metachromasia in groups A, B, and C were 0.033 ± 0.019, 0.089 ± 0.022, and 0.002 ± 0.001 mm 2 /mm 2 , respectively, at 4 weeks and 0.029 ± 0.022, 0.090 ± 0.039, and 0.003 ± 0.001 mm 2 /mm 2 , respectively, at 8 weeks. At 4 and 8 weeks postoperatively, significantly higher cartilage matrix production was observed in group B than in group C (4 weeks, P = .002; 8 weeks, P < .001). In green fluorescent protein-bone marrow chimeric rats in group B, bone marrow-derived chondrogenic cells infiltrated the fibrocartilage layer. Ultimate force to failure was significantly higher in group B (19.7 ± 3.4 N) than in group C (16.7 ± 2.0 N) at 8 weeks (P = .031). Drilling into the footprint and preserving the fibrocartilage improved the quality of repair tissue and biomechanical strength at the tendon-to-bone insertion after rotator cuff repair in an animal model. Drilling into the footprint and preserving the fibrocartilage can enhance repair of tendon-to-bone insertions. This method may be clinically useful in rotator cuff repair. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Structural testing of the Los Alamos National Laboratory Heat Source/Radioisotopic Thermoelectric Generator shipping container

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bronowski, D.R.; Madsen, M.M.

    The Heat Source/Radioisotopic Thermoelectric Generator shipping container is a Type B packaging design currently under development by Los Alamos National Laboratory. Type B packaging for transporting radioactive material is required to maintain containment and shielding after being exposed to the normal and hypothetical accident environments defined in Title 10 Code of Federal Regulations Part 71. A combination of testing and analysis is used to verify the adequacy of this package design. This report documents the test program portion of the design verification, using several prototype packages. Four types of testing were performed: 30-foot hypothetical accident condition drop tests in threemore » orientations, 40-inch hypothetical accident condition puncture tests in five orientations, a 21 psi external overpressure test, and a normal conditions of transport test consisting of a water spray and a 4 foot drop test. 18 refs., 104 figs., 13 tabs.« less

  9. RD2-MolPack-Chim3, a packaging cell line for stable production of lentiviral vectors for anti-HIV gene therapy.

    PubMed

    Stornaiuolo, Anna; Piovani, Bianca Maria; Bossi, Sergio; Zucchelli, Eleonora; Corna, Stefano; Salvatori, Francesca; Mavilio, Fulvio; Bordignon, Claudio; Rizzardi, Gian Paolo; Bovolenta, Chiara

    2013-08-01

    Over the last two decades, several attempts to generate packaging cells for lentiviral vectors (LV) have been made. Despite different technologies, no packaging clone is currently employed in clinical trials. We developed a new strategy for LV stable production based on the HEK-293T progenitor cells; the sequential insertion of the viral genes by integrating vectors; the constitutive expression of the viral components; and the RD114-TR envelope pseudotyping. We generated the intermediate clone PK-7 expressing constitutively gag/pol and rev genes and, by adding tat and rd114-tr genes, the stable packaging cell line RD2-MolPack, which can produce LV carrying any transfer vector (TV). Finally, we obtained the RD2-MolPack-Chim3 producer clone by transducing RD2-MolPack cells with the TV expressing the anti-HIV transgene Chim3. Remarkably, RD114-TR pseudovirions have much higher potency when produced by stable compared with transient technology. Most importantly, comparable transduction efficiency in hematopoietic stem cells (HSC) is obtained with 2-logs less physical particles respect to VSV-G pseudovirions produced by transient transfection. Altogether, RD2-MolPack technology should be considered a valid option for large-scale production of LV to be used in gene therapy protocols employing HSC, resulting in the possibility of downsizing the manufacturing scale by about 10-fold in respect to transient technology.

  10. Re-engineering adenovirus vector systems to enable high-throughput analyses of gene function.

    PubMed

    Stanton, Richard J; McSharry, Brian P; Armstrong, Melanie; Tomasec, Peter; Wilkinson, Gavin W G

    2008-12-01

    With the enhanced capacity of bioinformatics to interrogate extensive banks of sequence data, more efficient technologies are needed to test gene function predictions. Replication-deficient recombinant adenovirus (Ad) vectors are widely used in expression analysis since they provide for extremely efficient expression of transgenes in a wide range of cell types. To facilitate rapid, high-throughput generation of recombinant viruses, we have re-engineered an adenovirus vector (designated AdZ) to allow single-step, directional gene insertion using recombineering technology. Recombineering allows for direct insertion into the Ad vector of PCR products, synthesized sequences, or oligonucleotides encoding shRNAs without requirement for a transfer vector Vectors were optimized for high-throughput applications by making them "self-excising" through incorporating the I-SceI homing endonuclease into the vector removing the need to linearize vectors prior to transfection into packaging cells. AdZ vectors allow genes to be expressed in their native form or with strep, V5, or GFP tags. Insertion of tetracycline operators downstream of the human cytomegalovirus major immediate early (HCMV MIE) promoter permits silencing of transgenes in helper cells expressing the tet repressor thus making the vector compatible with the cloning of toxic gene products. The AdZ vector system is robust, straightforward, and suited to both sporadic and high-throughput applications.

  11. Life cycle assessment of EPS and CPB inserts: design considerations and end of life scenarios.

    PubMed

    Tan, Reginald B H; Khoo, Hsien H

    2005-02-01

    Expanded polystyrene (EPS) and corrugated paperboard (CPB) are used in many industrial applications, such as containers, shock absorbers or simply as inserts. Both materials pose two different types of environmental problems. The first is the pollution and resource consumption that occur during the production of these materials; the second is the growing landfills that arise out of the excessive disposal of these packaging materials. Life cycle assessment or LCA will be introduced in this paper as a useful tool to compare the environmental performance of both EPS and CPB throughout their life cycle stages. This paper is divided into two main parts. The first part investigates the environmental impacts of the production of EPS and CPB from 'cradle-to-gate', comparing two inserts--both the original and proposed new designs. In the second part, LCA is applied to investigate various end-of-life cases for the same materials. The study will evaluate the environmental impacts of the present waste management practices in Singapore. Several 'what-if' cases are also discussed, including various percentages of landfilling and incineration. The SimaPro LCA Version 5.0 software's Eco-indicator 99 method is used to investigate the following five environmental impact categories: climate change, acidification/eutrophication, ecotoxicity, fossil fuels and respiratory inorganics.

  12. The R package 'icosa' for coarse resolution global triangular and penta-hexagonal gridding

    NASA Astrophysics Data System (ADS)

    Kocsis, Adam T.

    2017-04-01

    With the development of the internet and the computational power of personal computers, open source programming environments have become indispensable for science in the past decade. This includes the increase of the GIS capacity of the free R environment, which was originally developed for statistical analyses. The flexibility of R made it a preferred programming tool in a multitude of disciplines from the area of the biological and geological sciences. Many of these subdisciplines operate with incidence (occurrence) data that are in a large number of cases to be grained before further analyses can be conducted. This graining is executed mostly by gridding data to cells of a Gaussian grid of various resolutions to increase the density of data in a single unit of the analyses. This method has obvious shortcomings despite the ease of its application: well-known systematic biases are induced to cell sizes and shapes that can interfere with the results of statistical procedures, especially if the number of incidence points influences the metrics in question. The 'icosa' package employs a common method to overcome this obstacle by implementing grids with roughly equal cell sizes and shapes that are based on tessellated icosahedra. These grid objects are essentially polyhedra with xyz Cartesian vertex data that are linked to tables of faces and edges. At its current developmental stage, the package uses a single method of tessellation which balances grid cell size and shape distortions, but its structure allows the implementation of various other types of tessellation algorithms. The resolution of the grids can be set by the number of breakpoints inserted into a segment forming an edge of the original icosahedron. Both the triangular and their inverted penta-hexagonal grids are available for creation with the package. The package also incorporates functions to look up coordinates in the grid very effectively and data containers to link data to the grid structure. The classes defined in the package are communicating with classes of the 'sp' and 'raster' packages and functions are supplied that allow resolution change and type conversions. Three-dimensional rendering is made available with the 'rgl' package and two-dimensional projections can be calculated using 'sp' and 'rgdal'. The package was developed as part of a project funded by the Deutsche Forschungsgemeinschaft (KO - 5382/1-1).

  13. Optimized Determination of Deployable Consumable Spares Packages

    DTIC Science & Technology

    2007-06-01

    also called deployable bench stock) • CRSP = Consumable Readiness Spares Package • COLT = Customer -Oriented Leveling Technique • ASM = Aircraft...changed please list both.) Original title on 712 A/B: Optimized Determination of Deployable Consumable Spares Packages If the title was revised...number. 1. REPORT DATE 01 JUN 2007 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Optimized Determination of Deployable Consumable

  14. Group B streptococci in women fitted with intrauterine devices.

    PubMed Central

    Mitchell, R G; Guillebaud, J; Day, D G

    1977-01-01

    A survey was made of group B streptococcal carriage at various sites in 100 women attending a clinic for the insertion of an intrauterine contraceptive device (IUD). Twenty-three women carried streptococci at one or more sites at the preinsertion visit, the vaginal carriage rate being 16%. Six months after insertion changes in carrier status were noted and there was evidence of a change of strain in four patients. Twenty-nine women were carriers at one or more sites at some stage of the study. There was no evidence that symptoms attributable to infection in patients fitted with an IUD were caused by group B streptococci. PMID:338639

  15. Mutational scanning reveals the determinants of protein insertion and association energetics in the plasma membrane.

    PubMed

    Elazar, Assaf; Weinstein, Jonathan; Biran, Ido; Fridman, Yearit; Bibi, Eitan; Fleishman, Sarel Jacob

    2016-01-29

    Insertion of helix-forming segments into the membrane and their association determines the structure, function, and expression levels of all plasma membrane proteins. However, systematic and reliable quantification of membrane-protein energetics has been challenging. We developed a deep mutational scanning method to monitor the effects of hundreds of point mutations on helix insertion and self-association within the bacterial inner membrane. The assay quantifies insertion energetics for all natural amino acids at 27 positions across the membrane, revealing that the hydrophobicity of biological membranes is significantly higher than appreciated. We further quantitate the contributions to membrane-protein insertion from positively charged residues at the cytoplasm-membrane interface and reveal large and unanticipated differences among these residues. Finally, we derive comprehensive mutational landscapes in the membrane domains of Glycophorin A and the ErbB2 oncogene, and find that insertion and self-association are strongly coupled in receptor homodimers.

  16. Terahertz MMICs and Antenna-in-Package Technology at 300 GHz for KIOSK Download System

    NASA Astrophysics Data System (ADS)

    Tajima, Takuro; Kosugi, Toshihiko; Song, Ho-Jin; Hamada, Hiroshi; El Moutaouakil, Amine; Sugiyama, Hiroki; Matsuzaki, Hideaki; Yaita, Makoto; Kagami, Osamu

    2016-12-01

    Toward the realization of ultra-fast wireless communications systems, the inherent broad bandwidth of the terahertz (THz) band is attracting attention, especially for short-range instant download applications. In this paper, we present our recent progress on InP-based THz MMICs and packaging techniques based on low-temperature co-fibered ceramic (LTCC) technology. The transmitter MMICs are based on 80-nm InP-based high electron mobility transistors (HEMTs). Using the transmitter packaged in an E-plane split-block waveguide and compact lens receiver packaged in LTCC multilayered substrates, we tested wireless data transmission up to 27 Gbps with the simple amplitude key shifting (ASK) modulation scheme. We also present several THz antenna-in-packaging solutions based on substrate integrated waveguide (SIW) technology. A vertical hollow (VH) SIW was applied to a compact medium-gain SIW antenna and low-loss interconnection integrated in LTCC multi-layer substrates. The size of the LTCC antennas with 15-dBi gain is less than 0.1 cm3. For feeding the antenna, we investigated an LTCC-integrated transition and polyimide transition to LTCC VH SIWs. These transitions exhibit around 1-dB estimated loss at 300 GHz and more than 35 GHz bandwidth with 10-dB return loss. The proposed package solutions make antennas and interconnections easy to integrate in a compact LTCC package with an MMIC chip for practical applications.

  17. Evaluation of Risk Versus Benefit Information in Direct-To-Consumer (DTC) Prescription Drug Television Advertisements.

    PubMed

    Fahim, Germin; Toscani, Michael; Barone, Joseph A; Wang, Chris; Gandhi, Shivani

    2018-01-01

    The FDA's Presenting Risk Information draft guidance from May 2009 states that the time of risk versus benefit is a factor taken into consideration when evaluating audio and video direct-to-consumer (DTC) broadcasts. The objective of the study is to evaluate the proportion of risk narration on television (TV) advertisements in comparison to the actual proportion of serious adverse effects findings across select therapeutic areas. The study reviews prescription drug TV advertisements between the years 2010 and 2015 separated by therapeutic class. Indicators to assess risk versus benefit are as follows: total benefit time, total risk time, total ad time, percentage proportion of risk, and number of serious adverse effects (SAEs) listed in the package insert. The objective is establishing proportion of risk-to-benefit narration across therapeutic areas and the proportion of risk narration compared to the number of SAEs in the package insert. These outcomes will reflect whether TV advertisements abide by the "fair balance" rule and if the time spent on risk narrations is proportional to the number of SAEs across therapeutic areas. An analysis of risk versus benefit showed that there was a vast range of percentage differences in risk versus benefit narration across the products selected. The majority of the products narrated showed a 40% to 60% risk-to-benefit ratio. Six out of the 10 products evaluated communicated applicable black box warnings. There was variability among the SAE percentages presented between products. Lack of consistency exists between risks versus benefit proportions among different drug products.

  18. The increase in prescriptions of bisphosphonates and the incidence proportion of osteonecrosis of the jaw after risk communication activities in Japan: a hospital-based cohort study†

    PubMed Central

    Sumi, Eriko; Yamazaki, Toru; Tanaka, Shiro; Yamamoto, Keiichi; Nakayama, Takeo; Bessho, Kazuhisa; Yokode, Masayuki

    2014-01-01

    Purpose The purpose of this study was to investigate the impact of risk communication about bisphosphonate (BP)-related osteonecrosis of the jaw (ONJ) on the number of reported cases to the Drug Adverse Reactions Reporting System and on the incidence proportion of ONJ in a hospital-based cohort study in Japan. Method We conducted a survey of the safety information on BP-related ONJ available from regulatory authorities, pharmaceutical manufacturers and academic associations. We also performed a trend analysis of a dataset from the Drug Adverse Reactions Reporting System and a sub-analysis, using previously constructed data from a retrospective cohort study. Results Risk communication from pharmaceutical manufacturers and academic associations began within 1 year after revisions were made to the package inserts, in October 2006. Twenty times more cases of ONJ have been reported to regulatory authority since 2007, compared with the period before 2007. In our cohort, the incidence proportion of ONJ during and after 2009 was four times greater than before 2009. During this period, BPs were frequently prescribed, whereas there was no increase in the use of alternative agents, such as selective estrogen receptor modulators. Conclusion ONJ was increasingly diagnosed after risk communication efforts, but the impact of the communications was not clear. Safety notifications were diligently disseminated after the package insert was revised. However, there was no surveillance for ONJ before the revision. © 2014 The Authors. Pharmacoepidemiology and Drug Safety published by John Wiley & Sons, Ltd. PMID:24399628

  19. Factors influencing subjects' comprehension of a set of medicine package inserts.

    PubMed

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2016-08-01

    Background Package inserts (PIs) should promote the safe and effective use of medicines. The comprehension of PIs is related to socio-demographic features, such as education. Objectives To evaluate the participants' comprehension of a sample of PIs and to build an explanatory model of subjects' understanding of the content of these documents. Setting The data were collected from municipalities, city halls, firefighters, the military, schools and charities from two Portuguese regions. Methods Cross-sectional descriptive survey: 503 participants, homogeneously distributed by education and gender. The self-administered tool comprised questions on socio-demographic data, literacy tasks and comprehension evaluation of 12 purposively selected PIs. A logistic regression analysis was used. Main outcome measures Scores of numeracy tasks and comprehension. Results The average comprehension score for the PIs was 63 % (±32 %), with 48 % (n = 239) of the participants scoring <75 %. The most important predictors in explaining a comprehension score ≥75 % were having >12 years of education and correctly performing a numeracy task [respectively, OR 49.6 (CI 95 %: 22.8-108) and OR 2.48 (CI 95 %: 1.5-4.2)]. Conclusion An explanatory model of subjects' knowledge about the content of the tested PIs was built. Given that a high level of education and literacy were found to be the most relevant predictors for acceptable comprehension rates, PIs should be clearly written to assure that they are understood by all potential users, including the less educated. The evaluated PIs may thus need to be simplified.

  20. Medication Safety During Pregnancy: Improving Evidence-Based Practice.

    PubMed

    Sinclair, Susan M; Miller, Richard K; Chambers, Christina; Cooper, Elizabeth M

    2016-01-01

    Nearly 90% of women in the United States have taken medications during pregnancy. Medication exposures during pregnancy can result in adverse pregnancy and neonatal outcomes including birth defects, fetal loss, intrauterine growth restriction, prematurity, and longer-term neurodevelopmental outcomes. Advising pregnant women about the safety of medication use during pregnancy is complicated by a lack of data necessary to engage the woman in an informed discussion. Routinely, health care providers turn to the package insert, yet this information can be incomplete and can be based entirely on animal studies. Often, adequate safety data are not available. In a busy clinical setting, health care providers need to be able to quickly locate the most up-to-date information in order to counsel pregnant women concerned about medication exposure. Deciding where to locate the best available information is difficult, particularly when the needed information does not exist. Pregnancy registries are initiated to obtain more data about the safety of specific medication exposures during pregnancy; however, these studies are slow to produce meaningful information, and when they do, the information may not be readily available in a published form. Health care providers have valuable data in their everyday practice that can expand the knowledge base about medication safety during pregnancy. This review aims to discuss the limitations of the package insert regarding medication safety during pregnancy, highlight additional resources available to health care providers to inform practice, and communicate the importance of pregnancy registries for expanding knowledge about medication safety during pregnancy. © 2016 by the American College of Nurse-Midwives.

  1. Unsuccessfully Treated Hypertension: A Major Public Health Problem With a Potential Solution.

    PubMed

    Furberg, Curt D; Sealey, Jean E; Blumenfeld, Jon D

    2017-09-01

    About one-half of all hypertensive adults do not have their blood pressure controlled. They are often prescribed medications that conform to national guidelines but they continue to have elevated blood pressure. This public health problem might be improved by applying plasma renin guided therapy. A contributor to the public health problem of unsuccessfully treated hypertension is that the circulating renin-angiotensin system (RAS) is not recognized in treatment guidelines as clinically relevant for the treatment of hypertension or as important as the body salt status for determining blood pressure levels. Another contributor to the problem is the lack of specificity in the package inserts for antihypertensive drugs. They do not specifically state under the heading "Indications" that RAS blockers are primarily most effective in hypertensive subjects with medium and high plasma renin levels; by contrast, natriuretic drugs are most effective in those with low plasma renin levels. Literature review. To address the problem of unsuccessfully treated hypertension, we recommend that the "Indications" section of package inserts for antihypertensive drugs be more specific. The primary indication for RAS blockers ought to be hypertension with medium and high plasma renin levels, and natriuretic agents for those with low plasma renin levels. Similar language ought to be added to treatment guidelines. Additionally, 3 other reasons for lack of blood pressure control also need to be addressed-failure to prescribe antihypertensive drugs to hypertensive subjects, failure of patients to fill prescriptions, and low drug adherence. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  2. An evaluation of the completeness of drug-drug interaction-related information in package inserts.

    PubMed

    Ng, Giok Qin; Sklar, Grant Edward; Chng, Hui Ting

    2017-02-01

    The project aimed to evaluate the completeness of drug-drug interaction (DDI)-related information in package inserts (PIs) and develop a systematic approach to conduct the evaluation. DDI-related information in the branded PIs of statins, macrolides, protease inhibitors and selected drugs of narrow therapeutic index (DNTI) were evaluated against the criteria distilled from the Food and Drug Administration (FDA) labelling recommendation guidance document. Decision trees were crafted and employed in the evaluation process. Scores were computed to give each PI an overall completeness score and individual criterion completeness score. The Kruskal-Wallis test and Dunn's multiple comparison test were used to assess the differences in the completeness scores. The mean overall completeness score of the 21 PIs was 35.7 ± 13.4 % (range 12.2-62 %). Eight out of the 11 individual evaluation criterion had a mean completeness score below 50 %. A subclass analysis conducted revealed that PIs from the different drug classes differed in the type of DDI-related information, such that they are more complete or less complete. The completeness score of DDI-related information in the PIs varied extensively amongst and within drug classes. A consensus between the authorities and drug companies on the type and quality of DDI-related information to be included could improve their completeness in PIs and make PIs a valuable source of DDI reference. Decision trees, albeit not validated yet, lay the groundwork for a valuable tool to evaluate DDI-related or other drug information.

  3. An L-section DC electric field switchable bulk acoustic wave solidly mounted resonator filter based on Ba0.5Sr0.5TiO3.

    PubMed

    Saddik, George N; York, Robert A

    2012-09-01

    This paper reports on the modeling, fabrication, and experimental results of a voltage switchable barium strontium titanate solidly mounted resonator filter at 6 GHz. The filter insertion loss was measured to be -4.26 dB and the return loss to be -13.5 dB. The 3-dB bandwidth was measured to be 72 MHz and the quality factor was calculated to be 83. The data were collected at a dc bias voltage of 10 V. Temperature data were also collected, and the filter demonstrated a 0.71-dB increase in insertion loss and a 7-MHz decrease in center frequency with increase in temperature.

  4. 48 CFR 552.217-71 - Notice Regarding Option(s).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Notice Regarding Option(s... Notice Regarding Option(s). As prescribed in 517.208(b), insert the following provision: Notice Regarding Option(s) (NOV 1992) The General Services Administration (GSA) has included an option to [Insert...

  5. 48 CFR 239.7306 - Solicitation provision and contract clause.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TECHNOLOGY Requirements for Information Relating to Supply Chain Risk 239.7306 Solicitation provision and contract clause. (a) Insert the provision at 252.239-7017, Notice of Supply Chain Risk, in all... as a supply. (b) Insert the clause at 252.239-7018, Supply Chain Risk, in all solicitations and...

  6. 42 CFR 414.108 - IOLs inserted in a physician's office.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 3 2014-10-01 2014-10-01 false IOLs inserted in a physician's office. 414.108 Section 414.108 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Fee...

  7. 49 CFR Appendix E to Part 227 - Use of Insert Earphones for Audiometric Testing

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION OCCUPATIONAL NOISE EXPOSURE Pt. 227, App. E Appendix.... B. Technicians who conduct audiometric tests must be trained to insert the earphones correctly into... audiometer. IV. Background Noise Levels Testing shall be conducted in a room where the background ambient...

  8. 7 CFR 201.39 - General procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... hand into the bulk and withdrawing representative portions. The hand is inserted in an open position and the fingers are held closely together while the hand is being inserted and the portion withdrawn... bag, the handfuls shall be taken from well-separated points. (b) For free-flowing seed in bags or bulk...

  9. 7 CFR 201.39 - General procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... hand into the bulk and withdrawing representative portions. The hand is inserted in an open position and the fingers are held closely together while the hand is being inserted and the portion withdrawn... bag, the handfuls shall be taken from well-separated points. (b) For free-flowing seed in bags or bulk...

  10. A manpower scheduling heuristic for aircraft maintenance application

    NASA Astrophysics Data System (ADS)

    Sze, San-Nah; Sze, Jeeu-Fong; Chiew, Kang-Leng

    2012-09-01

    This research studies a manpower scheduling for aircraft maintenance, focusing on in-flight food loading operation. A group of loading teams with flexible shifts is required to deliver and upload packaged meals from the ground kitchen to aircrafts in multiple trips. All aircrafts must be served within predefined time windows. The scheduling process takes into account of various constraints such as meal break allocation, multi-trip traveling and food exposure time limit. Considering the aircrafts movement and predefined maximum working hours for each loading team, the main objective of this study is to form an efficient roster by assigning a minimum number of loading teams to the aircrafts. We proposed an insertion based heuristic to generate the solutions in a short period of time for large instances. This proposed algorithm is implemented in various stages for constructing trips due to the presence of numerous constraints. The robustness and efficiency of the algorithm is demonstrated in computational results. The results show that the insertion heuristic more efficiently outperforms the company's current practice.

  11. Materials and structures technology insertion into spacecraft systems: Successes and challenges

    NASA Astrophysics Data System (ADS)

    Rawal, Suraj

    2018-05-01

    Over the last 30 years, significant advancements have led to the use of multifunctional materials and structures technologies in spacecraft systems. This includes the integration of adaptive structures, advanced composites, nanotechnology, and additive manufacturing technologies. Development of multifunctional structures has been directly influenced by the implementation of processes and tools for adaptive structures pioneered by Prof. Paolo Santini. Multifunctional materials and structures incorporating non-structural engineering functions such as thermal, electrical, radiation shielding, power, and sensors have been investigated. The result has been an integrated structure that offers reduced mass, packaging volume, and ease of integration for spacecraft systems. Current technology development efforts are being conducted to develop innovative multifunctional materials and structures designs incorporating advanced composites, nanotechnology, and additive manufacturing. However, these efforts offer significant challenges in the qualification and acceptance into spacecraft systems. This paper presents a brief overview of the technology development and successful insertion of advanced material technologies into spacecraft structures. Finally, opportunities and challenges to develop and mature next generation advanced materials and structures are presented.

  12. SU-8 microprobe with microelectrodes for monitoring electrical impedance in living tissues.

    PubMed

    Tijero, M; Gabriel, G; Caro, J; Altuna, A; Hernández, R; Villa, R; Berganzo, J; Blanco, F J; Salido, R; Fernández, L J

    2009-04-15

    This paper presents a minimally invasive needle-shaped probe capable of monitoring the electrical impedance of living tissues. This microprobe consists of a 160 microm thick SU-8 substrate containing four planar platinum (Pt) microelectrodes. We design the probe to minimize damage to the surrounding tissue and to be stiff enough to be inserted in living tissues. The proposed batch fabrication process is low cost and low time consuming. The microelectrodes obtained with this process are strongly adhered to the SU-8 substrate and their impedance does not depend on frequency variation. In vitro experiments are compared with previously developed Si and SiC based microprobes and results suggest that it is preferable to use the SU-8 based microprobes due to their flexibility and low cost. The microprobe is assembled on a flexible printed circuit FPC with a conductive glue, packaged with epoxy and wired to the external instrumentation. This flexible probe is inserted into a rat kidney without fracturing and succeeds in demonstrating the ischemia monitoring.

  13. Gamma inert sterilization: a solution to polyethylene oxidation?

    PubMed

    Medel, Francisco J; Kurtz, Steven M; Hozack, William J; Parvizi, Javad; Purtill, James J; Sharkey, Peter F; MacDonald, Daniel; Kraay, Matthew J; Goldberg, Victor; Rimnac, Clare M

    2009-04-01

    In the 1990s, oxidation was found to occur in ultra-high molecular weight polyethylene total joint replacement components following gamma irradiation and prolonged shelf aging in air. Orthopaedic manufacturers developed barrier packaging to reduce oxidation during and after radiation sterilization. The present study explores the hypothesis that polyethylene components sterilized in a low-oxygen environment undergo similar in vivo oxidative mechanisms as inserts sterilized in air. In addition, the potential influence of the different sterilization processes on the wear performance of the polyethylene components was examined. An analysis of oxidation, wear, and surface damage was performed for forty-eight acetabular liners and 123 tibial inserts. The mean implantation time was 12.3+/-3.7 years for thirty-one acetabular liners that had been gamma sterilized in air and 4.0+/-2.5 years for the seventeen acetabular liners that had been gamma sterilized in inert gas. The mean implantation time was 11.0+/-3.2 years for the twenty-six tibial inserts that had been sterilized in air and 2.8+/-2.2 years for the ninety-seven tibial inserts that had been gamma sterilized in inert gas. Oxidation and hydroperoxide levels were characterized in loaded and unloaded regions of the inserts. Measurable oxidation and oxidation potential were observed in all cohorts. The oxidation and hydroperoxide levels were regional. Surfaces with access to body fluids were more heavily oxidized than protected bearing surfaces were. This variation appeared to be greater in historical (gamma-in-air-sterilized) components. Regarding wear performance, historical and conventional acetabular liners showed similar wear penetration rates, whereas a low incidence of delamination was confirmed for the conventional tibial inserts in the first decade of implantation. The present study explores the impact of industry-wide changes in sterilization practices for polyethylene. We found lower oxidation and oxidation potential in the conventional acetabular liners and tibial inserts that had been gamma sterilized in inert gas as compared with the historical components that had been gamma sterilized in air. However, we also found strong evidence that conventional components undergo mechanisms of in vivo oxidation similar to those observed following gamma irradiation in air. In addition, gamma sterilization in inert gas did not provide polyethylene with a significant improvement in terms of wear resistance as compared with gamma sterilization in air, except for a lower incidence of delamination in the first decade of implantation for tibial inserts.

  14. Expression of human argininosuccinate synthetase after retroviral-mediated gene transfer.

    PubMed

    Wood, P A; Partridge, C A; O'Brien, W E; Beaudet, A L

    1986-09-01

    The cDNA sequence for human argininosuccinate synthetase (AS) was introduced into plasmid expression vectors with an SV40 promoter or Rous sarcoma virus promoter to construct pSV2-AS and pRSV-AS, respectively, and human enzyme was synthesized after gene transfer into Chinese hamster cells. The functional cDNA was inserted into the retroviral vectors pZIP-NeoSV(X) and pZIP-NeoSV(B). Ecotropic AS retrovirus was produced after calcium-phosphate-mediated gene transfer of these constructions into the packaging cell line psi-2, and viral titers up to 10(5) CFU/ml were obtained. Recombinant AS retrovirus was evaluated by detecting G-418-resistant colonies after infection of the rodent cells, XC, NRK, and 3T3. Colonies were also obtained when infected XC cells were selected in citrulline medium for expression of AS activity. Southern blot analysis of infected cells demonstrated that the recombinant retroviral genome was not altered grossly after infecting some rodent cells, while other cells showed evidence of rearrangement. A rapid assay for detecting AS retrovirus was developed based on the incorporation of [14C]citrulline into protein by intact 3T3 cells or XC cells.

  15. Investigating Block-Copolymer Micelle Dynamics for Tunable Cargo Delivery

    NASA Astrophysics Data System (ADS)

    Li, Xiuli; Kidd, Bryce; Cooksey, Tyler; Robertson, Megan; Madsen, Louis

    Block-copolymer micelles (BCPMs) can carry molecular cargo in a nanoscopic package that is tunable using polymer structure in combination with cargo properties, as well as with external stimuli such as temperature or pH. For example, BCPMs can be used in targeted anticancer drug delivery due to their biocompatibility, in vivo degradability and prolonged circulation time. We are using NMR spectroscopy and diffusometry as well as SANS to investigate BCPMs. Here we study a diblock poly(ethylene oxide)-b-(caprolactone) (PEO-PCL) that forms spherical micelles at 1% (w/v) in the mixed solvent D2O/THF-d8. We quantify the populations and diffusion coefficients of coexisting micelles and free unimers over a range of temperatures and solvent compositions. We use temperature as a stimulus to enhance unimer exchange and hence trigger cargo release, in some cases at a few degrees above body temperature. We present evidence for dominance of the insertion-expulsion mechanism of unimer exchange in these systems, and we map phase diagrams versus temperature and solvent composition. This study sheds light on how intermolecular interactions fundamentally affect cargo release, unimer exchange, and overall micelle tunability.

  16. Simulation of guided-wave ultrasound propagation in composite laminates: Benchmark comparisons of numerical codes and experiment.

    PubMed

    Leckey, Cara A C; Wheeler, Kevin R; Hafiychuk, Vasyl N; Hafiychuk, Halyna; Timuçin, Doğan A

    2018-03-01

    Ultrasonic wave methods constitute the leading physical mechanism for nondestructive evaluation (NDE) and structural health monitoring (SHM) of solid composite materials, such as carbon fiber reinforced polymer (CFRP) laminates. Computational models of ultrasonic wave excitation, propagation, and scattering in CFRP composites can be extremely valuable in designing practicable NDE and SHM hardware, software, and methodologies that accomplish the desired accuracy, reliability, efficiency, and coverage. The development and application of ultrasonic simulation approaches for composite materials is an active area of research in the field of NDE. This paper presents comparisons of guided wave simulations for CFRP composites implemented using four different simulation codes: the commercial finite element modeling (FEM) packages ABAQUS, ANSYS, and COMSOL, and a custom code executing the Elastodynamic Finite Integration Technique (EFIT). Benchmark comparisons are made between the simulation tools and both experimental laser Doppler vibrometry data and theoretical dispersion curves. A pristine and a delamination type case (Teflon insert in the experimental specimen) is studied. A summary is given of the accuracy of simulation results and the respective computational performance of the four different simulation tools. Published by Elsevier B.V.

  17. A single-channel implantable microstimulator for functional neuromuscular stimulation.

    PubMed

    Ziaie, B; Nardin, M D; Coghlan, A R; Najafi, K

    1997-10-01

    This paper describes a single-channel implantable microstimulator for functional neuromuscular stimulation. This device measures 2 x 2 x 10 mm3 and can be inserted into paralyzed muscle groups by expulsion from a hypodermic needle. Power and data to the device are supplied from outside by RF telemetry using an amplitude-modulated 2-MHz RF carrier generated using a high-efficiency class-E transmitter. The transmitted signal carries a 5-b address which selects one of the 32 possible microstimulators. The selected device then delivers up to 2 microC of charge store in a tantalum chip capacitor for up to 200 microseconds (10 mA) into loads of < 800 omega through a high-current thin-film iridium-oxide (IrOx) electrode (approximately 0.3 mm2 in area). A bi-CMOS receiver circuitry is used to: generate two regulated voltage supplies (4.5 and 9 V), recover a 2-MHz clock from the carrier, demodulate the address code, and activate the output current delivery circuitry upon the reception of an external command. The overall power dissipation of the receiver circuitry is 45-55 mW. The implant is hermetically packaged using a custom-made glass capsule.

  18. NDAS Hardware Translation Layer Development

    NASA Technical Reports Server (NTRS)

    Nazaretian, Ryan N.; Holladay, Wendy T.

    2011-01-01

    The NASA Data Acquisition System (NDAS) project is aimed to replace all DAS software for NASA s Rocket Testing Facilities. There must be a software-hardware translation layer so the software can properly talk to the hardware. Since the hardware from each test stand varies, drivers for each stand have to be made. These drivers will act more like plugins for the software. If the software is being used in E3, then the software should point to the E3 driver package. If the software is being used at B2, then the software should point to the B2 driver package. The driver packages should also be filled with hardware drivers that are universal to the DAS system. For example, since A1, A2, and B2 all use the Preston 8300AU signal conditioners, then the driver for those three stands should be the same and updated collectively.

  19. In Escherichia coli, MreB and FtsZ direct the synthesis of lateral cell wall via independent pathways that require PBP 2.

    PubMed

    Varma, Archana; Young, Kevin D

    2009-06-01

    In Escherichia coli, the cytoplasmic proteins MreB and FtsZ play crucial roles in ensuring that new muropeptide subunits are inserted into the cell wall in a spatially correct way during elongation and division. In particular, to retain a constant diameter and overall shape, new material must be inserted into the wall uniformly around the cell's perimeter. Current thinking is that MreB accomplishes this feat through intermediary proteins that tether peptidoglycan synthases to the outer face of the inner membrane. We tested this idea in E. coli by using a DD-carboxypeptidase mutant that accumulates pentapeptides in its peptidoglycan, allowing us to visualize new muropeptide incorporation. Surprisingly, inhibiting MreB with the antibiotic A22 did not result in uneven insertion of new wall, although the cells bulged and lost their rod shapes. Instead, uneven (clustered) incorporation occurred only if MreB and FtsZ were inactivated simultaneously, providing the first evidence in E. coli that FtsZ can direct murein incorporation into the lateral cell wall independently of MreB. Inhibiting penicillin binding protein 2 (PBP 2) alone produced the same clustered phenotype, implying that MreB and FtsZ tether peptidoglycan synthases via a common mechanism that includes PBP 2. However, cell shape was determined only by the presence or absence of MreB and not by the even distribution of new wall material as directed by FtsZ.

  20. Identifying transposon insertions and their effects from RNA-sequencing data.

    PubMed

    de Ruiter, Julian R; Kas, Sjors M; Schut, Eva; Adams, David J; Koudijs, Marco J; Wessels, Lodewyk F A; Jonkers, Jos

    2017-07-07

    Insertional mutagenesis using engineered transposons is a potent forward genetic screening technique used to identify cancer genes in mouse model systems. In the analysis of these screens, transposon insertion sites are typically identified by targeted DNA-sequencing and subsequently assigned to predicted target genes using heuristics. As such, these approaches provide no direct evidence that insertions actually affect their predicted targets or how transcripts of these genes are affected. To address this, we developed IM-Fusion, an approach that identifies insertion sites from gene-transposon fusions in standard single- and paired-end RNA-sequencing data. We demonstrate IM-Fusion on two separate transposon screens of 123 mammary tumors and 20 B-cell acute lymphoblastic leukemias, respectively. We show that IM-Fusion accurately identifies transposon insertions and their true target genes. Furthermore, by combining the identified insertion sites with expression quantification, we show that we can determine the effect of a transposon insertion on its target gene(s) and prioritize insertions that have a significant effect on expression. We expect that IM-Fusion will significantly enhance the accuracy of cancer gene discovery in forward genetic screens and provide initial insight into the biological effects of insertions on candidate cancer genes. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

Top