36th International Symposium on Combustion (ISOC2016)
2016-12-01
GREENHOUSE GASES / IC ENGINE COMBUSTION I GAS TURBINE COMBUSTION I NOVEL COMBUSTION CONCEPTS, TECHNOLOGIES AND SYSTEMS 15. SUBJECT TERMS Reaction...pollutants and greenhouse gases; IC engine combustion; Gas turbine combustion; Novel combustion concepts, technologies and systems 16. SECURITY...PLENARY LECTURE TRANSFER (15 min) am Turbulent Flames IC Engines Laminar Flames Reaction Kinetics Gas Turbines Soot Solid Fuels/Pollutants
On the thermodynamics of waste heat recovery from internal combustion engine exhaust gas
NASA Astrophysics Data System (ADS)
Meisner, G. P.
2013-03-01
The ideal internal combustion (IC) engine (Otto Cycle) efficiency ηIC = 1-(1/r)(γ - 1) is only a function of engine compression ratio r =Vmax/Vmin and exhaust gas specific heat ratio γ = cP/cV. Typically r = 8, γ = 1.4, and ηIC = 56%. Unlike the Carnot Cycle where ηCarnot = 1-(TC/TH) for a heat engine operating between hot and cold heat reservoirs at TH and TC, respectively, ηIC is not a function of the exhaust gas temperature. Instead, the exhaust gas temperature depends only on the intake gas temperature (ambient), r, γ, cV, and the combustion energy. The ejected exhaust gas heat is thermally decoupled from the IC engine and conveyed via the exhaust system (manifold, pipe, muffler, etc.) to ambient, and the exhaust system is simply a heat engine that does no useful work. The maximum fraction of fuel energy that can be extracted from the exhaust gas stream as useful work is (1-ηIC) × ηCarnot = 32% for TH = 850 K (exhaust) and TC = 370 K (coolant). This waste heat can be recovered using a heat engine such as a thermoelectric generator (TEG) with ηTEG> 0 in the exhaust system. A combined IC engine and TEG system can generate net useful work from the exhaust gas waste heat with efficiency ηWH = (1-ηIC) × ηCarnot ×ηTEG , and this will increase the overall fuel efficiency of the total system. Recent improvements in TEGs yield ηTEG values approaching 15% giving a potential total waste heat conversion efficiency of ηWH = 4.6%, which translates into a fuel economy improvement approaching 5%. This work is supported by the US DOE under DE-EE0005432.
Automotive Stirling engine development program
NASA Technical Reports Server (NTRS)
Ernst, W.; Richey, A.; Farrell, R.; Riecke, G.; Smith, G.; Howarth, R.; Cronin, M.; Simetkosky, M.; Meacher, J.
1986-01-01
The major accomplishments were the completion of the Basic Stirling Engine (BSE) and the Stirling Engine System (SES) designs on schedule, the approval and acceptance of those designs by NASA, and the initiation of manufacture of BSE components. The performance predictions indicate the Mod II engine design will meet or exceed the original program goals of 30% improvement in fuel economy over a conventional Internal Combustion (IC) powered vehicle, while providing acceptable emissions. This was accomplished while simultaneously reducing Mod II engine weight to a level comparable with IC engine power density, and packaging the Mod II in a 1985 Celebrity with no external sheet metal changes. The projected mileage of the Mod II Celebrity for the combined urban and highway CVS cycle is 40.9 mpg which is a 32% improvement over the IC Celebrity. If additional potential improvements are verified and incorporated in the Mod II, the mileage could increase to 42.7 mpg.
NASA Technical Reports Server (NTRS)
Bose, Bimal K.; Kim, Min-Huei
1995-01-01
The report essentially summarizes the work performed in order to satisfy the above project objective. In the beginning, different energy storage devices, such as battery, flywheel and ultra capacitor are reviewed and compared, establishing the superiority of the battery. Then, the possible power sources, such as IC engine, diesel engine, gas turbine and fuel cell are reviewed and compared, and the superiority of IC engine has been established. Different types of machines for drive motor/engine generator, such as induction machine, PM synchronous machine and switched reluctance machine are compared, and the induction machine is established as the superior candidate. Similar discussion was made for power converters and devices. The Insulated Gate Bipolar Transistor (IGBT) appears to be the most superior device although Mercury Cadmium Telluride (MCT) shows future promise. Different types of candidate distribution systems with the possible combinations of power and energy sources have been discussed and the most viable system consisting of battery, IC engine and induction machine has been identified. Then, HFAC system has been compared with the DC system establishing the superiority of the former. The detailed component sizing calculations of HFAC and DC systems reinforce the superiority of the former. A preliminary control strategy has been developed for the candidate HFAC system. Finally, modeling and simulation study have been made to validate the system performance. The study in the report demonstrates the superiority of HFAC distribution system for next generation electric/hybrid vehicle.
Time Resolved Digital PIV Measurements of Flow Field Cyclic Variation in an Optical IC Engine
NASA Astrophysics Data System (ADS)
Jarvis, S.; Justham, T.; Clarke, A.; Garner, C. P.; Hargrave, G. K.; Halliwell, N. A.
2006-07-01
Time resolved digital particle image velocimetry (DPIV) experimental data is presented for the in-cylinder flow field development of a motored four stroke spark ignition (SI) optical internal combustion (IC) engine. A high speed DPIV system was employed to quantify the velocity field development during the intake and compression stroke at an engine speed of 1500 rpm. The results map the spatial and temporal development of the in-cylinder flow field structure allowing comparison between traditional ensemble average and cycle average flow field structures. Conclusions are drawn with respect to engine flow field cyclic variations.
Chemistry and the Internal Combustion Engine II: Pollution Problems.
ERIC Educational Resources Information Center
Hunt, C. B.
1979-01-01
Discusses pollution problems which arise from the use of internal combustion (IC) engines in the United Kingdom (UK). The IC engine exhaust emissions, controlling IC engine pollution in the UK, and some future developments are also included. (HM)
A design procedure for fan inflow control structures
NASA Technical Reports Server (NTRS)
Gedge, M. R.
1980-01-01
Significant differences exist in the noise generated by engine in flight and engines operating on the test stand. It was observed that these differences can be reduced by use of an inflow control structure (ICS) in the static test configuration. The results of the second phase of a three phase program are described and the results of a test program conducted to assess and modify various theoretical models, leading to the development of an ICS design system is summarized.
Floor Plans Engine Removal Platform, Hold Down Arm Platform, ...
Floor Plans - Engine Removal Platform, Hold Down Arm Platform, Hydraulic Equipment Platforms, Isometric Cutaway of Engine Removal Platform, Isometric Cutaway of Hold Down Arm Platform, Isometric Cutaway of Hydraulic Platforms and Engine Support System Access - Marshall Space Flight Center, Saturn V S-IC Static Test Facility, West Test Area, Huntsville, Madison County, AL
Droplet-Wall/Film Impact in IC Engine Applications
2017-08-14
Report: Droplet-Wall/Film Impact in IC Engine Applications (ARO Topic 1.4.1 under ARO’s Dr. Ralph A. Anthenien) The views, opinions and/or findings...in IC Engine Applications (ARO Topic 1.4.1 under ARO’s Dr. Ralph A. Anthenien) Report Term: 0-Other Email: cklaw@princeton.edu Distribution Statement...associated with spraying in internal combustion engines (ICEs). Fuels sprayed inside engines can impact with the internal surfaces and thus not only
V&V Plan for FPGA-based ESF-CCS Using System Engineering Approach.
NASA Astrophysics Data System (ADS)
Maerani, Restu; Mayaka, Joyce; El Akrat, Mohamed; Cheon, Jung Jae
2018-02-01
Instrumentation and Control (I&C) systems play an important role in maintaining the safety of Nuclear Power Plant (NPP) operation. However, most current I&C safety systems are based on Programmable Logic Controller (PLC) hardware, which is difficult to verify and validate, and is susceptible to software common cause failure. Therefore, a plan for the replacement of the PLC-based safety systems, such as the Engineered Safety Feature - Component Control System (ESF-CCS), with Field Programmable Gate Arrays (FPGA) is needed. By using a systems engineering approach, which ensures traceability in every phase of the life cycle, from system requirements, design implementation to verification and validation, the system development is guaranteed to be in line with the regulatory requirements. The Verification process will ensure that the customer and stakeholder’s needs are satisfied in a high quality, trustworthy, cost efficient and schedule compliant manner throughout a system’s entire life cycle. The benefit of the V&V plan is to ensure that the FPGA based ESF-CCS is correctly built, and to ensure that the measurement of performance indicators has positive feedback that “do we do the right thing” during the re-engineering process of the FPGA based ESF-CCS.
Interband Cascade Photovoltaic Cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Rui Q.; Santos, Michael B.; Johnson, Matthew B.
2014-09-24
In this project, we are performing basic and applied research to systematically investigate our newly proposed interband cascade (IC) photovoltaic (PV) cells [1]. These cells follow from the great success of infrared IC lasers [2-3] that pioneered the use of quantum-engineered IC structures. This quantum-engineered approach will enable PV cells to efficiently convert infrared radiation from the sun or other heat source, to electricity. Such cells will have important applications for more efficient use of solar energy, waste-heat recovery, and power beaming in combination with mid-infrared lasers. The objectives of our investigations are to: achieve extensive understanding of the fundamentalmore » aspects of the proposed PV structures, develop the necessary knowledge for making such IC PV cells, and demonstrate prototype working PV cells. This research will focus on IC PV structures and their segments for utilizing infrared radiation with wavelengths from 2 to 5 μm, a range well suited for emission by heat sources (1,000-2,000 K) that are widely available from combustion systems. The long-term goal of this project is to push PV technology to longer wavelengths, allowing for relatively low-temperature thermal sources. Our investigations address material quality, electrical and optical properties, and their interplay for the different regions of an IC PV structure. The tasks involve: design, modeling and optimization of IC PV structures, molecular beam epitaxial growth of PV structures and relevant segments, material characterization, prototype device fabrication and testing. At the end of this program, we expect to generate new cutting-edge knowledge in the design and understanding of quantum-engineered semiconductor structures, and demonstrate the concepts for IC PV devices with high conversion efficiencies.« less
A linear acoustic model for intake wave dynamics in IC engines
NASA Astrophysics Data System (ADS)
Harrison, M. F.; Stanev, P. T.
2004-01-01
In this paper, a linear acoustic model is described that has proven useful in obtaining a better understanding of the nature of acoustic wave dynamics in the intake system of an internal combustion (IC) engine. The model described has been developed alongside a set of measurements made on a Ricardo E6 single cylinder research engine. The simplified linear acoustic model reported here produces a calculation of the pressure time-history in the port of an IC engine that agrees fairly well with measured data obtained on the engine fitted with a simple intake system. The model has proved useful in identifying the role of pipe resonance in the intake process and has led to the development of a simple hypothesis to explain the structure of the intake pressure time history: the early stages of the intake process are governed by the instantaneous values of the piston velocity and the open area under the valve. Thereafter, resonant wave action dominates the process. The depth of the early depression caused by the moving piston governs the intensity of the wave action that follows. A pressure ratio across the valve that is favourable to inflow is maintained and maximized when the open period of the valve is such to allow at least, but no more than, one complete oscillation of the pressure at its resonant frequency to occur while the valve is open.
2009-02-01
management, available at <http://www.iso.org/ iso /en/CatalogueDetailPage.CatalogueDetail?CSNUMBER=39612&ICS1=35&ICS2=40 &ICS3=>. ISO /IEC 27001 . Information...Management of the Systems Engineering Process. [ ISO /IEC 27001 ] ISO /IEC 27001 :2005. Information technology -- Security techniques -- Information security...software life cycles [ ISO /IEC 15026]. Software assurance is a key element of national security and homeland security. It is critical because dramatic
NASA Astrophysics Data System (ADS)
Colins, Karen; Li, Liqian; Liu, Yu
2017-05-01
Mass production of widely used semiconductor digital integrated circuits (ICs) has lowered unit costs to the level of ordinary daily consumables of a few dollars. It is therefore reasonable to contemplate the idea of an engineered system that consumes unshielded low-cost ICs for the purpose of measuring gamma radiation dose. Underlying the idea is the premise of a measurable correlation between an observable property of ICs and radiation dose. Accumulation of radiation-damage-induced state changes or error events is such a property. If correct, the premise could make possible low-cost wide-area radiation dose measurement systems, instantiated as wireless sensor networks (WSNs) with unshielded consumable ICs as nodes, communicating error events to a remote base station. The premise has been investigated quantitatively for the first time in laboratory experiments and related analyses performed at the Canadian Nuclear Laboratories. State changes or error events were recorded in real time during irradiation of samples of ICs of different types in a 60Co gamma cell. From the error-event sequences, empirical distribution functions of dose were generated. The distribution functions were inverted and probabilities scaled by total error events, to yield plots of the relationship between dose and error tallies. Positive correlation was observed, and discrete functional dependence of dose quantiles on error tallies was measured, demonstrating the correctness of the premise. The idea of an engineered system that consumes unshielded low-cost ICs in a WSN, for the purpose of measuring gamma radiation dose over wide areas, is therefore tenable.
Nonlinear system analysis in bipolar integrated circuits
NASA Astrophysics Data System (ADS)
Fang, T. F.; Whalen, J. J.
1980-01-01
Since analog bipolar integrated circuits (IC's) have become important components in modern communication systems, the study of the Radio Frequency Interference (RFI) effects in bipolar IC amplifiers is an important subject for electromagnetic compatibility (EMC) engineering. The investigation has focused on using the nonlinear circuit analysis program (NCAP) to predict RF demodulation effects in broadband bipolar IC amplifiers. The audio frequency (AF) voltage at the IC amplifier output terminal caused by an amplitude modulated (AM) RF signal at the IC amplifier input terminal was calculated and compared to measured values. Two broadband IC amplifiers were investigated: (1) a cascode circuit using a CA3026 dual differential pair; (2) a unity gain voltage follower circuit using a micro A741 operational amplifier (op amp). Before using NCAP for RFI analysis, the model parameters for each bipolar junction transistor (BJT) in the integrated circuit were determined. Probe measurement techniques, manufacturer's data, and other researcher's data were used to obtain the required NCAP BJT model parameter values. An important contribution included in this effort is a complete set of NCAP BJT model parameters for most of the transistor types used in linear IC's.
Electrophoretic display technologies for e-book readers: system integration aspects
NASA Astrophysics Data System (ADS)
Gentric, Philippe
2011-03-01
Emerging screen technologies, such as Electrophoretic Displays (EPD) used in E-book Readers, are changing product power requirements due to their advantageous properties such as bi-stability (effective "zero power" static display) and reflective mode of operation (no backlight). We will first review the emerging screen technologies under the angle of system and IC design impact. We will explain power management consequences for IC design, with a focus on Application Engine SOCs for the wireless/portable markets.
NASA Technical Reports Server (NTRS)
Richard, Jacques C.
1995-01-01
This paper presents a dynamic model of an internal combustion engine coupled to a variable pitch propeller. The low-order, nonlinear time-dependent model is useful for simulating the propulsion system of general aviation single-engine light aircraft. This model is suitable for investigating engine diagnostics and monitoring and for control design and development. Furthermore, the model may be extended to provide a tool for the study of engine emissions, fuel economy, component effects, alternative fuels, alternative engine cycles, flight simulators, sensors, and actuators. Results show that the model provides a reasonable representation of the propulsion system dynamics from zero to 10 Hertz.
1965-03-01
The S-IC-T stage was hoisted into the S-IC static test stand at the Marshall Space Flight Center. The S-IC-T stage was a static test vehicle not intended for flight. It was ground tested repeatedly over a period of many months to prove the vehicle's propulsion system. The 280,000-pound stage, 138 feet long and 33 feet in diameter, housed the fuel and liquid oxygen tanks that held a total of 4,400,000 pounds of liquid oxygen and kerosene. The two tanks are cornected by a 26-foot-long intertank section. Other parts of the booster included the forward skirt and the thrust structure, on which the engines were to be mounted. Five F-1 engines, each weighing 10 tons, gave the booster a total thrust of 7,500,000 pounds, roughly equivalent to 160 million horsepower.
1965-03-01
The S-IC-T stage is hoisted into the S-IC static test stand at the Marshall Space Flight Center. The S-IC-T stage is a static test vehicle not intended for flight. It was ground tested repeatedly over a period of many months proving the vehicle's propulsion system. The 280,000-pound stage, 138 feet long and 33 feet in diameter, houses the fuel and liquid oxygen tanks that hold a total of 4,400,000 pounds of liquid oxygen and kerosene. The two tanks are cornected by a 26-foot-long intertank section. Other parts of the booster included the forward skirt and the thrust structure, on which the engines were to be mounted. Five F-1 engines, each weighing 10 tons, gave the booster a total thrust of 7,500,000 pounds, roughly equivalent to 160 million horsepower.
1965-03-01
The S-IC-T stage was hoisted into the S-IC Static Test Stand at the Marshall Space Flight Center. The S-IC-T stage was a static test vehicle, not intended for flight. It was ground tested repeatedly over a period of many months to prove the vehicle's propulsion system. The 280,000-pound stage, 138 feet long and 33 feet in diameter, housed the fuel and liquid oxygen tanks that held a total of 4,400,000 pounds of liquid oxygen and kerosene. The two tanks were cornected by a 26-foot intertank section. Other parts of the booster included the forward skirt and the thrust structure, on which the engines were to be mounted. Five F-1 engines, each weighing 10 tons, gave the booster a total thrust of 7,500,000 pounds, roughly equivalent to 160 million horsepower.
NASA Astrophysics Data System (ADS)
Gladwin, D.; Stewart, P.; Stewart, J.
2011-02-01
This article addresses the problem of maintaining a stable rectified DC output from the three-phase AC generator in a series-hybrid vehicle powertrain. The series-hybrid prime power source generally comprises an internal combustion (IC) engine driving a three-phase permanent magnet generator whose output is rectified to DC. A recent development has been to control the engine/generator combination by an electronically actuated throttle. This system can be represented as a nonlinear system with significant time delay. Previously, voltage control of the generator output has been achieved by model predictive methods such as the Smith Predictor. These methods rely on the incorporation of an accurate system model and time delay into the control algorithm, with a consequent increase in computational complexity in the real-time controller, and as a necessity relies to some extent on the accuracy of the models. Two complementary performance objectives exist for the control system. Firstly, to maintain the IC engine at its optimal operating point, and secondly, to supply a stable DC supply to the traction drive inverters. Achievement of these goals minimises the transient energy storage requirements at the DC link, with a consequent reduction in both weight and cost. These objectives imply constant velocity operation of the IC engine under external load disturbances and changes in both operating conditions and vehicle speed set-points. In order to achieve these objectives, and reduce the complexity of implementation, in this article a controller is designed by the use of Genetic Programming methods in the Simulink modelling environment, with the aim of obtaining a relatively simple controller for the time-delay system which does not rely on the implementation of real time system models or time delay approximations in the controller. A methodology is presented to utilise the miriad of existing control blocks in the Simulink libraries to automatically evolve optimal control structures.
NASA Technical Reports Server (NTRS)
2004-01-01
This cutaway illustration shows the Saturn V S-IC (first) stage with detailed callouts of the components. The S-IC Stage is 138 feet long and 33 feet in diameter, producing 7,500,000 pounds of thrust through five F-1 engines that are powered by liquid oxygen and kerosene. Four of the engines are mounted on an outer ring and gimbal for control purposes. The fifth engine is rigidly mounted in the center. When ignited, the roar produced by the five engines equals the sound of 8,000,000 hi-fi sets.
NASA Astrophysics Data System (ADS)
Bauke, Stephan; Golibrzuch, Kai; Wackerbarth, Hainer; Fendt, Peter; Zigan, Lars; Seefeldt, Stefan; Thiele, Olaf; Berg, Thomas
2018-05-01
Lowering greenhouse gas emissions is one of the most challenging demands of today's society. Especially, the automotive industry struggles with the development of more efficient internal combustion (IC) engines. As an alternative to conventional fuels, methane has the potential for a significant emission reduction. In methane fuelled engines, the process of mixture formation, which determines the properties of combustion after ignition, differs significantly from gasoline and diesel engines and needs to be understood and controlled in order to develop engines with high efficiency. This work demonstrates the development of a gas sensing system that can serve as a diagnostic tool for measuring crank-angle resolved relative air-fuel ratios in methane-fuelled near-production IC engines. By application of non-dispersive infrared absorption spectroscopy at two distinct spectral regions in the ν3 absorption band of methane around 3.3 μm, the system is able to determine fuel density and temperature simultaneously. A modified spark plug probe allows for straightforward application at engine test stations. Here, the application of the detection system in a rapid compression machine is presented, which enables validation and characterization of the system on well-defined gas mixtures under engine-like dynamic conditions. In extension to a recent proof-of-principle study, a refined data analysis procedure is introduced that allows the correction of artefacts originating from mechanical distortions of the sensor probe. In addition, the measured temperatures are compared to data obtained with a commercially available system based on the spectrally resolved detection of water absorption in the near infrared.
ICS logging solution for network-based attacks using Gumistix technology
NASA Astrophysics Data System (ADS)
Otis, Jeremy R.; Berman, Dustin; Butts, Jonathan; Lopez, Juan
2013-05-01
Industrial Control Systems (ICS) monitor and control operations associated with the national critical infrastructure (e.g., electric power grid, oil and gas pipelines and water treatment facilities). These systems rely on technologies and architectures that were designed for system reliability and availability. Security associated with ICS was never an inherent concern, primarily due to the protections afforded by network isolation. However, a trend in ICS operations is to migrate to commercial networks via TCP/IP in order to leverage commodity benefits and cost savings. As a result, system vulnerabilities are now exposed to the online community. Indeed, recent research has demonstrated that many exposed ICS devices are being discovered using readily available applications (e.g., ShodanHQ search engine and Google-esque queries). Due to the lack of security and logging capabilities for ICS, most knowledge about attacks are derived from real world incidents after an attack has already been carried out and the damage has been done. This research provides a method for introducing sensors into the ICS environment that collect information about network-based attacks. The sensors are developed using an inexpensive Gumstix platform that can be deployed and incorporated with production systems. Data obtained from the sensors provide insight into attack tactics (e.g., port scans, Nessus scans, Metasploit modules, and zero-day exploits) and characteristics (e.g., attack origin, frequency, and level of persistence). Findings enable security professionals to draw an accurate, real-time awareness of the threats against ICS devices and help shift the security posture from reactionary to preventative.
ERIC Educational Resources Information Center
Bernstein, Bianca L.; Bekki, Jennifer M.; Wilkins, Kerrie G.; Harrison, Caroline J.
2016-01-01
Strong interpersonal communication skills (ICS) are critical for educational and career success, but effective and widely accessible training systems are not available. This paper describes a 2 × 2 × 2 experimental study of an online, educational simulation for practice with the ICS of active listening. The simulation was customized for women…
NASA Astrophysics Data System (ADS)
Justham, T.; Jarvis, S.; Clarke, A.; Garner, C. P.; Hargrave, G. K.; Halliwell, N. A.
2006-07-01
Simultaneous intake and in-cylinder digital particle image velocimetry (DPIV) experimental data is presented for a motored spark ignition (SI) optical internal combustion (IC) engine. Two individual DPIV systems were employed to study the inter-relationship between the intake and in-cylinder flow fields at an engine speed of 1500 rpm. Results for the intake runner velocity field at the time of maximum intake valve lift are compared to incylinder velocity fields later in the same engine cycle. Relationships between flow structures within the runner and cylinder were seen to be strong during the intake stroke but less significant during compression. Cyclic variations within the intake runner were seen to affect the large scale bulk flow motion. The subsequent decay of the large scale motions into smaller scale turbulent structures during the compression stroke appear to reduce the relationship with the intake flow variations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Hara, J.M.; W. Gunther, G. Martinez-Guridi
New and advanced reactors will use integrated digital instrumentation and control (I&C) systems to support operators in their monitoring and control functions. Even though digital systems are typically highly reliable, their potential for degradation or failure could significantly affect operator performance and, consequently, impact plant safety. The U.S. Nuclear Regulatory Commission (NRC) supported this research project to investigate the effects of degraded I&C systems on human performance and plant operations. The objective was to develop human factors engineering (HFE) review guidance addressing the detection and management of degraded digital I&C conditions by plant operators. We reviewed pertinent standards and guidelines,more » empirical studies, and plant operating experience. In addition, we conducted an evaluation of the potential effects of selected failure modes of the digital feedwater system on human-system interfaces (HSIs) and operator performance. The results indicated that I&C degradations are prevalent in plants employing digital systems and the overall effects on plant behavior can be significant, such as causing a reactor trip or causing equipment to operate unexpectedly. I&C degradations can impact the HSIs used by operators to monitor and control the plant. For example, sensor degradations can make displays difficult to interpret and can sometimes mislead operators by making it appear that a process disturbance has occurred. We used the information obtained as the technical basis upon which to develop HFE review guidance. The guidance addresses the treatment of degraded I&C conditions as part of the design process and the HSI features and functions that support operators to monitor I&C performance and manage I&C degradations when they occur. In addition, we identified topics for future research.« less
Industry-Oriented Laboratory Development for Mixed-Signal IC Test Education
ERIC Educational Resources Information Center
Hu, J.; Haffner, M.; Yoder, S.; Scott, M.; Reehal, G.; Ismail, M.
2010-01-01
The semiconductor industry is lacking qualified integrated circuit (IC) test engineers to serve in the field of mixed-signal electronics. The absence of mixed-signal IC test education at the collegiate level is cited as one of the main sources for this problem. In response to this situation, the Department of Electrical and Computer Engineering at…
The Nutating Engine-Prototype Engine Progress Report and Test Results
NASA Technical Reports Server (NTRS)
Meitner, Peter L.; Boruta, Mike
2006-01-01
A prototype of a new, internal combustion (IC) engine concept has been completed. The Nutating Engine features an internal disk nutating (wobbling) on a Z-shaped power shaft. The engine is exceedingly compact, and several times more power dense than any conventional (reciprocating or rotary) IC engine. This paper discusses lessons learned during the prototype engine's development and provides details of its construction. In addition, results of the initial performance tests of the various components, as well as the complete engine, are summarized.
NASA Astrophysics Data System (ADS)
Haghgoo, Esmail; Zamani, Mohammad; Sharbati, Ali
2017-02-01
The point of this article is introducing the usage of electronic power steering (ESP) system in IKCO SAMAND vehicle and investigating on it's benefit's. Also the operation of electronic steering system and it's performance in IKCO SAMAND vehicle have been described. The optimization of IC engine efficiency and it's fuel consumption have been simulated via ADVISOR software used in MATLAB software. Usually, mechanical steering systems and hydraulic steering systems are producing inside IRAN that the mechanical types have not accepted because of it's too many disadvantages. The hydraulic steering systems, that have been replaced with mechanical types, indeed have the same features with mechanical types but with a difference which they have a hydraulic booster to facilitate the rotation of steering wheel. Beside advantages in hydraulic systems, they are some disadvantages in this system that one of the most important of them is reducing the output power of engine. To restore this power dissipated, we use ESP systems. In this article output diagrams given by software, are showing that IKCO SAMAND vehicle which equipped with ESP system, exerts less torque and power on steering wheel. This improves the safety of driver and also performance of the vehicle at high speeds and reduces fuel consumption beside increasing the efficiency of IC engine.
The EPA GHG Center collaborated with the New York State Energy Research and Development Authority (NYSERDA) to evaluate the performance of the Climate Energy freewatt Micro-Combined Heat and Power System. The system is a reciprocating internal combustion (IC) engine distributed e...
The scaling of performance and losses in miniature internal combustion engines
NASA Astrophysics Data System (ADS)
Menon, Shyam Kumar
Miniature glow ignition internal combustion (IC) piston engines are an off--the--shelf technology that could dramatically increase the endurance of miniature electric power supplies and the range and endurance of small unmanned air vehicles provided their overall thermodynamic efficiencies can be increased to 15% or better. This thesis presents the first comprehensive analysis of small (<500 g) piston engine performance. A unique dynamometer system is developed that is capable of making reliable measurements of engine performance and losses in these small engines. Methodologies are also developed for measuring volumetric, heat transfer, exhaust, mechanical, and combustion losses. These instruments and techniques are used to investigate the performance of seven single-cylinder, two-stroke, glow fueled engines ranging in size from 15 to 450 g (0.16 to 7.5 cm3 displacement). Scaling rules for power output, overall efficiency, and normalized power are developed from the data. These will be useful to developers of micro-air vehicles and miniature power systems. The data show that the minimum length scale of a thermodynamically viable piston engine based on present technology is approximately 3 mm. Incomplete combustion is the most important challenge as it accounts for 60-70% of total energy losses. Combustion losses are followed in order of importance by heat transfer, sensible enthalpy, and friction. A net heat release analysis based on in-cylinder pressure measurements suggest that a two--stage combustion process occurs at low engine speeds and equivalence ratios close to 1. Different theories based on burning mode and reaction kinetics are proposed to explain the observed results. High speed imaging of the combustion chamber suggests that a turbulent premixed flame with its origin in the vicinity of the glow plug is the primary driver of combustion. Placing miniature IC engines on a turbulent combustion regime diagram shows that they operate in the 'flamelet in eddy' regime whereas conventional--scale engines operate mostly in the 'wrinkled laminar flame sheet' regime. Taken together, the results show that the combustion process is the key obstacle to realizing the potential of small IC engines. Overcoming this obstacle will require new diagnostic techniques, measurements, combustion models, and high temperature materials.
Lidar In-space Technology Experiment (LITE) Electronics Overview
NASA Technical Reports Server (NTRS)
Blythe, Michael P.; Couch, Richard H.; Rowland, Carroll W.; Kitchen, Wayne L.; Regan, Curtis P.; Koch, Michael R.; Antill, Charles W.; Stevens, William T.; Rollins, Courtney H.; Kist, Edward H.
1992-01-01
The LITE electronics system consists of the following seven subsystems: Laser Transmitter Module (LTM), Boresight Assembly (BA), Aft-Optics Electronics (AOE), Digital Data Handling Unit (DDHU), Engineering Data System (EDS), Instrument Controller (IC), and the Ground Support Equipment (GSE). Each of these subsystems is discussed.
1980-01-01
ting Oils 6. PERFORMING 04G. REPORT NUMBER -7 AUTHOR(s) 8 . CONTRACT OR GRANT NUMBER(s) O /Thomna-s F. Wynn, Jr: Capt, USAF 9. PERFORMING ORGANIZATION...EXCITED FURNACE ATOMIC FLUORESCENCE SYSTEM FOR THE DETERMINATION OF WEAR METALS IN JET ENGINE LUBRICATING OILS \\Ac ces-.ic’flr For DDC TL3 Unp-nnounced...DETERMINATION OF WEAR METALS IN JET ENGINE LUBRICATING OILS By Thomas F. Wynn, Jr. March, 1980 Chairman: James D. Winefordner Major Department: Chemistry A
A GRB and Broad-lined Type Ic Supernova from a Single Central Engine
NASA Astrophysics Data System (ADS)
Barnes, Jennifer; Duffell, Paul C.; Liu, Yuqian; Modjaz, Maryam; Bianco, Federica B.; Kasen, Daniel; MacFadyen, Andrew I.
2018-06-01
Unusually high velocities (≳0.1c) and correspondingly high kinetic energies have been observed in a subset of Type Ic supernovae (so-called “broad-lined Ic” supernovae; SNe Ic-BL), prompting a search for a central engine model capable of generating such energetic explosions. A clue to the explosion mechanism may lie in the fact that all supernovae that accompany long-duration gamma-ray bursts (GRBs) belong to the SN Ic-BL class. Using a combination of two-dimensional relativistic hydrodynamics and radiation transport calculations, we demonstrate that the central engine responsible for long GRBs can also trigger an SN Ic-BL. We find that a reasonable GRB engine injected into a stripped Wolf–Rayet progenitor produces a relativistic jet with energy ∼1051 erg, as well as an SN whose synthetic light curves and spectra are fully consistent with observed SNe Ic-BL during the photospheric phase. As a result of the jet’s asymmetric energy injection, the SN spectra and light curves depend on viewing angle. The impact of viewing angle on the spectrum is particularly pronounced at early times, while the viewing-angle dependence for the light curves (∼10% variation in bolometric luminosity) persists throughout the photospheric phase.
1964-12-01
At the Marshall Space Flight Center (MSFC), the fuel tank assembly for the Saturn V S-IC-T (static test stage) fuel tank assembly is mated to the liquid oxygen (LOX) tank in building 4705. This stage underwent numerous static firings at the newly-built S-IC Static Test Stand at the MSFC west test area. The S-IC (first) stage used five F-1 engines that produced a total thrust of 7,500,000 pounds as each engine produced 1,500,000 pounds of thrust. The S-IC stage lifted the Saturn V vehicle and Apollo spacecraft from the launch pad.
Comparative Study of the MTFA, ICS, and SQRI Image Quality Metrics for Visual Display Systems
1991-09-01
reasonable image quality predictions across select display and viewing condition parameters. 101 6.0 REFERENCES American National Standard for Human Factors Engineering of ’ Visual Display Terminal Workstations . ANSI
A Way to End the IC Designer Shortage.
ERIC Educational Resources Information Center
Robinson, Arthur L.
1980-01-01
Discusses the problem of the shortage of engineers capable of designing advanced integrated circuits (IC) and presents some suggestions for increasing the number of IC designers in universities and semiconductor companies. (HM)
Overcoming Present-Day Powerplant Limitations Via Unconventional Engine Configurations
NASA Technical Reports Server (NTRS)
Meitner, Peter L.
2006-01-01
The Army Research Laboratory s Vehicle Technology Directorate is sponsoring the prototype development of three unconventional engine concepts - two intermittent combustion (IC) engines and one turbine engine (via SBIR (Small Business Innovative Research) contracts). The IC concepts are the Nutating Engine and the Bonner Engine, and the turbine concept is the POWER Engine. Each of the three engines offers unique and greatly improved capabilities (which cannot be achieved by present-day powerplants), while offering significant reductions in size and weight. This paper presents brief descriptions of the physical characteristics of the three engines, and discusses their performance potentials, as well as their development status.
Holographic aids for internal combustion engine flow studies
NASA Technical Reports Server (NTRS)
Regan, C.
1984-01-01
Worldwide interest in improving the fuel efficiency of internal combustion (I.C.) engines has sparked research efforts designed to learn more about the flow processes of these engines. The flow fields must be understood prior to fuel injection in order to design efficient valves, piston geometries, and fuel injectors. Knowledge of the flow field is also necessary to determine the heat transfer to combustion chamber surfaces. Computational codes can predict velocity and turbulence patterns, but experimental verification is mandatory to justify their basic assumptions. Due to their nonintrusive nature, optical methods are ideally suited to provide the necessary velocity verification data. Optical sytems such as Schlieren photography, laser velocimetry, and illuminated particle visualization are used in I.C. engines, and now their versatility is improved by employing holography. These holographically enhanced optical techniques are described with emphasis on their applications in I.C. engines.
NASA Astrophysics Data System (ADS)
Rahman, Ataur; Sharif, Sazzad; Mohiuddin, AKM; Faris Ismail, Ahmed; Izan, Sany Ihsan
2017-03-01
Continuously variable transmission (CVT) system transmits the engine /battery power to the car driving wheel smoothly and efficiently. Cars with CVT produces some noise and slow acceleration to meet the car power demand on initial start-ups and slow speed. The car noise is produced as a result of CVT adjustment the engine speed with the hydraulic pressure. The current CVT problems incurred due to the slow response of hydraulic pressure and CVT fluid viscosity due to the development of heat.The aim of this study is to develop electromagnetic actuated CVT (EMA-CVT) with intelligent switching controlling system (ICS). The experimental results of ¼ scale EMA shows that it make the acceleration time of the car in 3.5-5 sec which is 40% less than the hydraulic CVT in the market. The EMA develops the electromagnetic force in the ranged of 350 -1200 N for the supply current in the range of 10-15 amp. This study introduced fuzzy intelligent system (FIS) to predict the EMA system dynamic behaviour in order to identify the current control for the EMA actuation during operation of the CVT. It is expecting that the up scale EMA-CVT would reduce the 75% of vehicle power transmission loss by accelerating vehicle in 5 sec and save the IC engine power consumption about 20% which will makes the vehicle energy efficient (EEV) and reduction of green house gas reduction.
NASA Astrophysics Data System (ADS)
Kurchatkin, I. V.; Gorshkalev, A. A.; Blagin, E. V.
2017-01-01
This article deals with developed methods of the working processes modelling in the combustion chamber of an internal combustion engine (ICE). Methods includes description of the preparation of a combustion chamber 3-d model, setting of the finite-element mesh, boundary condition setting and solution customization. Aircraft radial engine M-14 was selected for modelling. The cycle of cold blowdown in the ANSYS IC Engine software was carried out. The obtained data were compared to results of known calculation methods. A method of engine’s induction port improvement was suggested.
1968-01-01
This is a cutaway view of the Saturn V first stage, known as the S-IC, detailing the five F-1 engines and fuel cells. The S-IC stage is 138 feet long and 33 feet in diameter, producing more than 7,500,000 pounds of thrust through the five F-1 engines that are powered by liquid oxygen and kerosene. Four of the engines are mounted on an outer ring and gimbal for control purposes. The fifth engine is rigidly mounted in the center. When ignited, the roar produced by the five engines equals the sound of 8,000,000 hi-fi sets.
2004-04-15
This cutaway illustration shows the Saturn V S-IC (first) stage with detailed callouts of the components. The S-IC Stage is 138 feet long and 33 feet in diameter, producing 7,500,000 pounds of thrust through five F-1 engines that are powered by liquid oxygen and kerosene. Four of the engines are mounted on an outer ring and gimbal for control purposes. The fifth engine is rigidly mounted in the center. When ignited, the roar produced by the five engines equals the sound of 8,000,000 hi-fi sets.
1967-01-01
This illustration shows a cutaway drawing with callouts of the major components for the S-IC (first) stage of the Saturn V launch vehicle. The S-IC stage is 138 feet long and 33 feet in diameter, producing more than 7,500,000 pounds of thrust through five F-1 engines powered by liquid oxygen and kerosene. Four of the engines are mounted on an outer ring and gimball for control purposes. The fifth engine is rigidly mounted in the center. When ignited, the roar produced by the five engines equals the sound of 8,000,000 hi-fi sets.
2016-01-01
development requires wind tunnels and ranges that do not currently exist. Furthermore, continued technology matura- tion is needed for thermal management...designed with conceptual design engine model (at existing technology level), or existing propul- sion system, or modified propulsion system (e.g...internal cameras reading gauges and dials and switch positions , directly tapping into current or future avion- ics service buses and integrating
Ultra-precision engineering in lithographic exposure equipment for the semiconductor industry.
Schmidt, Robert-H Munnig
2012-08-28
The developments in lithographic tools for the production of an integrated circuit (IC) are ruled by 'Moore's Law': the density of components on an IC doubles in about every two years. The corresponding size reduction of the smallest detail in an IC entails several technological breakthroughs. The wafer scanner, the exposure system that defines those details, is the determining factor in these developments. This review deals with those aspects of the positioning systems inside these wafer scanners that enable the extension of Moore's Law into the future. The design of these systems is increasingly difficult because of the accuracy levels in the sub-nanometre range coupled with motion velocities of several metres per second. In addition to the use of feedback control for the reduction of errors, high-precision model-based feed-forward control is required with an almost ideally reproducible motion-system behaviour and a strict limitation of random disturbing events. The full mastering of this behaviour even includes material drift on an atomic scale and is decisive for the future success of these machines.
Solving the 56Ni Puzzle of Magnetar-powered Broad-lined Type IC Supernovae
NASA Astrophysics Data System (ADS)
Wang, Ling-Jun; Han, Yan-Hui; Xu, Dong; Wang, Shan-Qin; Dai, Zi-Gao; Wu, Xue-Feng; Wei, Jian-Yan
2016-11-01
Broad-lined Type Ic supernovae (SNe Ic-BL) are of great importance because their association with long-duration gamma-ray bursts (LGRBs) holds the key to deciphering the central engine of LGRBs, which refrains from being unveiled despite decades of investigation. Among the two popularly hypothesized types of central engine, I.e., black holes and strongly magnetized neutron stars (magnetars), there is mounting evidence that the central engine of GRB-associated SNe (GRB-SNe) is rapidly rotating magnetars. Theoretical analysis also suggests that magnetars could be the central engine of SNe Ic-BL. What puzzled the researchers is the fact that light-curve modeling indicates that as much as 0.2{--}0.5 {M}⊙ of 56Ni was synthesized during the explosion of the SNe Ic-BL, which is unfortunately in direct conflict with current state-of-the-art understanding of magnetar-powered 56Ni synthesis. Here we propose a dynamic model of magnetar-powered SNe to take into account the acceleration of the ejecta by the magnetar, as well as the thermalization of the injected energy. Assuming that the SN kinetic energy comes exclusively from the magnetar acceleration, we find that although a major fraction of the rotational energy of the magnetar is to accelerate the SN ejecta, a tiny fraction of this energy deposited as thermal energy of the ejecta is enough to reduce the needed 56Ni to 0.06 M ⊙ for both SN 1997ef and SN 2007ru. We therefore suggest that magnetars could power SNe Ic-BL in aspects both of energetics and of 56Ni synthesis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Blarigan, P.
A hydrogen fueled engine is being developed specifically for the auxiliary power unit (APU) in a series type hybrid vehicle. Hydrogen is different from other internal combustion (IC) engine fuels, and hybrid vehicle IC engine requirements are different from those of other IC vehicle engines. Together these differences will allow a new engine design based on first principles that will maximize thermal efficiency while minimizing principal emissions. The experimental program is proceeding in four steps: (1) Demonstration of the emissions and the indicated thermal efficiency capability of a standard CLR research engine modified for higher compression ratios and hydrogen fueledmore » operation. (2) Design and test a new combustion chamber geometry for an existing single cylinder research engine, in an attempt to improve on the baseline indicated thermal efficiency of the CLR engine. (3) Design and build, in conjunction with an industrial collaborator, a new full scale research engine designed to maximize brake thermal efficiency. Include a full complement of combustion diagnostics. (4) Incorporate all of the knowledge thus obtained in the design and fabrication, by an industrial collaborator, of the hydrogen fueled engine for the hybrid vehicle power train illustrator. Results of the CLR baseline engine testing are presented, as well as preliminary data from the new combustion chamber engine. The CLR data confirm the low NOx produced by lean operation. The preliminary indicated thermal efficiency data from the new combustion chamber design engine show an improvement relative to the CLR engine. Comparison with previous high compression engine results shows reasonable agreement.« less
A CWT-based methodology for piston slap experimental characterization
NASA Astrophysics Data System (ADS)
Buzzoni, M.; Mucchi, E.; Dalpiaz, G.
2017-03-01
Noise and vibration control in mechanical systems has become ever more significant for automotive industry where the comfort of the passenger compartment represents a challenging issue for car manufacturers. The reduction of piston slap noise is pivotal for a good design of IC engines. In this scenario, a methodology has been developed for the vibro-acoustic assessment of IC diesel engines by means of design changes in piston to cylinder bore clearance. Vibration signals have been analysed by means of advanced signal processing techniques taking advantage of cyclostationarity theory. The procedure departs from the analysis of the Continuous Wavelet Transform (CWT) in order to identify a representative frequency band of piston slap phenomenon. Such a frequency band has been exploited as the input data in the further signal processing analysis that involves the envelope analysis of the second order cyclostationary component of the signal. The second order harmonic component has been used as the benchmark parameter of piston slap noise. An experimental procedure of vibrational benchmarking is proposed and verified at different operational conditions in real IC engines actually equipped on cars. This study clearly underlines the crucial role of the transducer positioning when differences among real piston-to-cylinder clearances are considered. In particular, the proposed methodology is effective for the sensors placed on the outer cylinder wall in all the tested conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovesdi, C.; Joe, J.; Boring, R.
The primary objective of the United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program is to sustain operation of the existing commercial nuclear power plants (NPPs) through a multi-pathway approach in conducting research and development (R&D). The Advanced Instrumentation, Information, and Control (II&C) System Technologies pathway conducts targeted R&D to address aging and reliability concerns with legacy instrumentation and control (I&C) and other information systems in existing U.S. NPPs. Control room modernization is an important part following this pathway, and human factors experts at Idaho National Laboratory (INL) have been involved in conducting R&D to supportmore » migration of new digital main control room (MCR) technologies from legacy analog and legacy digital I&C. This paper describes a human factors engineering (HFE) process that supports human-system interface (HSI) design in MCR modernization activities, particularly with migration of old digital to new digital I&C. The process described in this work is an expansion from the LWRS Report INL/EXT-16-38576, and is a requirements-driven approach that aligns with NUREG-0711 requirements. The work described builds upon the existing literature by adding more detail around key tasks and decisions to make when transitioning from HSI Design into Verification and Validation (V&V). The overall objective of this process is to inform HSI design and elicit specific, measurable, and achievable human factors criteria for new digital technologies. Upon following this process, utilities should have greater confidence with transitioning from HSI design into V&V.« less
1967-03-01
The Saturn V configuration is shown in inches and meters as illustrated by the Boeing Company. The Saturn V vehicle consisted of three stages: the S-IC (first) stage powered by five F-1 engines, the S-II (second) stage powered by five J-2 engines, the S-IVB (third) stage powered by one J-2 engine. A top for the first three stages was designed to contain the instrument unit, the guidance system, the Apollo spacecraft, and the escape system. The Apollo spacecraft consisted of the lunar module, the service module, and the command module. The Saturn V was designed perform lunar and planetary missions and it was capable of placing 280,000 pounds into Earth orbit.
2012-12-10
combustion (IC) engine , Type 907, and its dat file was modified to match the expected fuel consumption and performance of the ...temperature output by the AS desorber. Depending on this DB set temperature, fuel would be burned to raise the temperature of the engine exhaust stream...in the simulations, it was based upon experimental data provided for this project indicating the performance of a 3 kW diesel
Finding a roadmap to achieve large neuromorphic hardware systems
Hasler, Jennifer; Marr, Bo
2013-01-01
Neuromorphic systems are gaining increasing importance in an era where CMOS digital computing techniques are reaching physical limits. These silicon systems mimic extremely energy efficient neural computing structures, potentially both for solving engineering applications as well as understanding neural computation. Toward this end, the authors provide a glimpse at what the technology evolution roadmap looks like for these systems so that Neuromorphic engineers may gain the same benefit of anticipation and foresight that IC designers gained from Moore's law many years ago. Scaling of energy efficiency, performance, and size will be discussed as well as how the implementation and application space of Neuromorphic systems are expected to evolve over time. PMID:24058330
NASA Technical Reports Server (NTRS)
Olson, E. M.
1986-01-01
Presently, there are many difficulties associated with implementing application specific custom or semi-custom (standard cell based) integrated circuits (ICs) into JPL flight projects. One of the primary difficulties is developing prototype semi-custom integrated circuits for use and evaluation in engineering prototype flight hardware. The prototype semi-custom ICs must be extremely cost-effective and yet still representative of flight qualifiable versions of the design. A second difficulty is encountered in the transport of the design from engineering prototype quality to flight quality. Normally, flight quality integrated circuits have stringent quality standards, must be radiation resistant and should consume minimal power. It is often not necessary or cost effective, however, to impose such stringent quality standards on engineering models developed for systems analysis in controlled lab environments. This article presents work originally initiated for ground based applications that also addresses these two problems. Furthermore, this article suggests a method that has been shown successful in prototyping flight quality semi-custom ICs through the Metal Oxide Semiconductor Implementation Service (MOSIS) program run by the University of Southern California's Information Sciences Institute. The method has been used successfully to design and fabricate through the MOSIS three different semi-custom prototype CMOS p-well chips. The three designs make use of the work presented and were designed consistent with design techniques and structures that are flight qualifiable, allowing one hour transfer of the design from engineering model status to flight qualifiable foundry-ready status through methods outlined in this article.
Study of Periodical Flow Heat Transfer in an Internal Combustion Engine
NASA Astrophysics Data System (ADS)
Luo, Xi
In-cylinder heat transfer is one of the most critical physical behaviors which has a direct influence on engine out emission and thermal efficiency for IC engine. In-cylinder wall temperature has to be precisely controlled to achieve high efficiency and low emission. However, this cannot be done without knowing gas-to-wall heat flux. This study reports on the development of a technique suitable for engine in-cylinder surface temperature measurement, as the traditional method is "hard to reach." A laser induced phosphorescence technique was used to study in-cylinder wall temperature effects on engine out unburned hydrocarbons during the engine transitional period (warm up). A linear correlation was found between the cylinder wall surface temperature and the unburned hydrocarbons at mediate and high charge densities. At low charge density, no clear correlation was observed because of miss-fire events. A new auto background correction infrared (IR) diagnostic was developed to measure the instantaneous in-cylinder surface temperature at 0.1 CAD resolution. A numerical mechanism was designed to suppress relatively low-frequency background noise and provide an accurate in-cylinder surface temperature measurements with an error of less than 1.4% inside the IC engine. In addition, a proposed optical coating reduced time delay errors by 50% compared to more conventional thermocouple techniques. A new cycle-averaged Res number was developed for an IC engine to capture the characteristics of engine flow. Comparison and scaling between different engine flow parameters are available by matching the averaged Res number. From experimental results, the engine flow motion was classified as intermittently turbulent, and it is different from the original fully developed turbulent assumption, which has previously been used in almost all engine simulations. The intermittent turbulence could have a great impact on engine heat transfer because of the transitional turbulence effect. Engine 3D CFD model further proves the existence of transitional turbulence flow. A new multi zone heat transfer model is proposed for IC engines only. The model includes pressure work effects and improved heat transfer prediction compared to the standard Law of the wall model.
NASA Technical Reports Server (NTRS)
Al Hassan, Mohammad; Britton, Paul; Hatfield, Glen Spencer; Novack, Steven D.
2017-01-01
Field Programmable Gate Arrays (FPGAs) integrated circuits (IC) are one of the key electronic components in today's sophisticated launch and space vehicle complex avionic systems, largely due to their superb reprogrammable and reconfigurable capabilities combined with relatively low non-recurring engineering costs (NRE) and short design cycle. Consequently, FPGAs are prevalent ICs in communication protocols and control signal commands. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.
Yoo, Jihyung; Prikhodko, Vitaly; Parks, James E; Perfetto, Anthony; Geckler, Sam; Partridge, William P
2016-04-01
The need for more environmentally friendly and efficient energy conversion is of paramount importance in developing and designing next-generation internal combustion (IC) engines for transportation applications. One effective solution to reducing emissions of mono-nitrogen oxides (NOx) is exhaust gas recirculation (EGR), which has been widely implemented in modern vehicles. However, cylinder-to-cylinder and cycle-to-cycle variations in the charge-gas uniformity can be a major barrier to optimum EGR implementation on multi-cylinder engines, and can limit performance, stability, and efficiency. Precise knowledge and fine control over the EGR system is therefore crucial, particularly for optimizing advanced engine concepts such as reactivity controlled compression ignition (RCCI). An absorption-based laser diagnostic was developed to study spatiotemporal charge-gas distributions in an IC engine intake manifold in real-time. The laser was tuned to an absorption band of carbon dioxide (CO2), a standard exhaust-gas marker, near 2.7 µm. The sensor was capable of probing four separate measurement locations simultaneously, and independently analyzing EGR fraction at speeds of 5 kHz (1.2 crank-angle degree (CAD) at 1 k RPM) or faster with high accuracy. The probes were used to study spatiotemporal EGR non-uniformities in the intake manifold and ultimately promote the development of more efficient and higher performance engines. © The Author(s) 2016.
1964-11-01
This image shows the Saturn V S-IC-T stage (S-IC static test article) fuel tank being attached to the thrust structure in the vehicle assembly building at the Marshall Space Flight Center (MSFC). The S-IC stage utilized five F-1 engines that used liquid oxygen and kerosene as propellant and provided a combined thrust of 7,500,000 pounds.
1964-12-01
The fuel tank assembly of the Saturn V S-IC (first) stage is readied to be mated to the liquid oxygen tank at the Marshall Space Flight Center. The fuel tank carried kerosene as its fuel. The S-IC stage utilized five F-1 engines that used kerosene and liquid oxygen as propellant. Each engine provided 1,500,000 pounds of thrust. This stage lifted the entire vehicle and Apollo spacecraft from the launch pad.
1964-12-01
The fuel tank assembly for the Saturn V S-IC (first) stage arrived at the Marshall Space Flight Center, building 4707, for mating to the liquid oxygen tank. The fuel tank carried kerosene as its fuel. The S-IC stage used five F-1 engines, that used kerosene and liquid oxygen as propellant and each engine provided 1,500,000 pounds of thrust. This stage lifted the entire vehicle and Apollo spacecraft from the launch pad.
Golibrzuch, Kai; Digulla, Finn-Erik; Bauke, Stephan; Wackerbarth, Hainer; Thiele, Olaf; Berg, Thomas
2017-08-01
We present the development and the first application of an optical sensor system that allows single-cycle determination of methane (CH 4 ) concentration inside internal combustion (IC) engines. We use non-dispersive infrared absorption spectroscopy to detect the CH 4 density with a time resolution up to 33 μs at acquisition rates of 30 kHz. The measurement scheme takes advantage of the strong temperature dependence of the absorption band applying two detection channels for CH 4 that detect different spectral regions of the ν 3 anti-symmetric C-H-stretch absorption. The strategy allows the simultaneous determination of fuel concentration as well as gas temperature. We show the proof-of-concept by validation of the measurement strategy in static pressure cell experiments as well as its application to a methane-fueled IC engine using a modified spark plug probe. Our results clearly demonstrate that it is crucial to determine the CH 4 temperature in the probe volume. Due to thermal influences of the sensor probe, the temperature needed to calculate the desired quantities (fuel density, fuel concentration) significantly differs from the gas phase temperature in the rest of the combustion chamber and estimations from standard thermodynamic models, e.g., polytropic compression, will fail.
Analysis of the Space Shuttle main engine simulation
NASA Technical Reports Server (NTRS)
Deabreu-Garcia, J. Alex; Welch, John T.
1993-01-01
This is a final report on an analysis of the Space Shuttle Main Engine Program, a digital simulator code written in Fortran. The research was undertaken in ultimate support of future design studies of a shuttle life-extending Intelligent Control System (ICS). These studies are to be conducted by NASA Lewis Space Research Center. The primary purpose of the analysis was to define the means to achieve a faster running simulation, and to determine if additional hardware would be necessary for speeding up simulations for the ICS project. In particular, the analysis was to consider the use of custom integrators based on the Matrix Stability Region Placement (MSRP) method. In addition to speed of execution, other qualities of the software were to be examined. Among these are the accuracy of computations, the useability of the simulation system, and the maintainability of the program and data files. Accuracy involves control of truncation error of the methods, and roundoff error induced by floating point operations. It also involves the requirement that the user be fully aware of the model that the simulator is implementing.
Model Identification and Control System Design for the Lambda Unmanned Research Vehicle
1991-09-01
AD-A241 859 D T IC_ _ _ _ _ __ OCT 21921MODEL IDENTIFICATION AND CONTROL SYSTEM DESIGN FOR THE LAMBDA UNMANNED RESEARCH VEHICLE: THESIS Gerald A...23 191K MODEL IDENTIFICATION AND CONTROL SYSTEM DESIGN FOR THE LAMBDA UNMANNED RESEARCH VEHICLE THESIS Gerald A. Swift, First Lieutenant, USAF AFIT...UNMANNED RESEARCH VEHICLE THESIS Presented to the Faculty of the School of Engineering of the Air Force Institute of Technology Air University in Partial
Instrument control software development process for the multi-star AO system ARGOS
NASA Astrophysics Data System (ADS)
Kulas, M.; Barl, L.; Borelli, J. L.; Gässler, W.; Rabien, S.
2012-09-01
The ARGOS project (Advanced Rayleigh guided Ground layer adaptive Optics System) will upgrade the Large Binocular Telescope (LBT) with an AO System consisting of six Rayleigh laser guide stars. This adaptive optics system integrates several control loops and many different components like lasers, calibration swing arms and slope computers that are dispersed throughout the telescope. The purpose of the instrument control software (ICS) is running this AO system and providing convenient client interfaces to the instruments and the control loops. The challenges for the ARGOS ICS are the development of a distributed and safety-critical software system with no defects in a short time, the creation of huge and complex software programs with a maintainable code base, the delivery of software components with the desired functionality and the support of geographically distributed project partners. To tackle these difficult tasks, the ARGOS software engineers reuse existing software like the novel middleware from LINC-NIRVANA, an instrument for the LBT, provide many tests at different functional levels like unit tests and regression tests, agree about code and architecture style and deliver software incrementally while closely collaborating with the project partners. Many ARGOS ICS components are already successfully in use in the laboratories for testing ARGOS control loops.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anheier, Norman C.; Suter, Jonathan D.; Qiao, Hong
2013-08-06
This report intends to support Department of Energy’s Office of Nuclear Energy (DOE-NE) Nuclear Energy Research and Development Roadmap and industry stakeholders by evaluating optical-based instrumentation and control (I&C) concepts for advanced small modular reactor (AdvSMR) applications. These advanced designs will require innovative thinking in terms of engineering approaches, materials integration, and I&C concepts to realize their eventual viability and deployability. The primary goals of this report include: 1. Establish preliminary I&C needs, performance requirements, and possible gaps for AdvSMR designs based on best available published design data. 2. Document commercial off-the-shelf (COTS) optical sensors, components, and materials in termsmore » of their technical readiness to support essential AdvSMR in-vessel I&C systems. 3. Identify technology gaps by comparing the in-vessel monitoring requirements and environmental constraints to COTS optical sensor and materials performance specifications. 4. Outline a future research, development, and demonstration (RD&D) program plan that addresses these gaps and develops optical-based I&C systems that enhance the viability of future AdvSMR designs. The development of clean, affordable, safe, and proliferation-resistant nuclear power is a key goal that is documented in the Nuclear Energy Research and Development Roadmap. This roadmap outlines RD&D activities intended to overcome technical, economic, and other barriers, which currently limit advances in nuclear energy. These activities will ensure that nuclear energy remains a viable component to this nation’s energy security.« less
1962-10-26
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC test stand, related facilities were built during this time. Built to the north of the massive S-IC test stand, was the F-1 Engine test stand. The F-1 test stand, a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken October 26, 1962, depicts the excavation process of the single engine F-1 stand.
1962-11-15
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC test stand, related facilities were built during this time. Built to the north of the massive S-IC test stand, was the F-1 Engine test stand. The F-1 test stand, a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken November 15, 1962, depicts the excavation process of the single engine F-1 stand site.
1965-04-16
This photograph depicts a dramatic view of the first test firing of all five F-1 engines for the Saturn V S-IC stage at the Marshall Space Flight Center. The testing lasted a full duration of 6.5 seconds. It also marked the first test performed in the new S-IC static test stand and the first test using the new control blockhouse. The S-IC stage is the first stage, or booster, of a 364-foot long rocket that ultimately took astronauts to the Moon. Operating at maximum power, all five of the engines produced 7,500,000 pounds of thrust. Required to hold down the brute force of a 7,500,000-pound thrust, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and cement, planted down to bedrock 40 feet below ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the up position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. When the Saturn V S-IC first stage was placed upright in the stand , the five F-1 engine nozzles pointed downward on a 1,900 ton, water-cooled deflector. To prevent melting damage, water was sprayed through small holes in the deflector at the rate 320,000 gallons per minute.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xiaodong; Hossain, Faisal; Leung, L. Ruby
In this study a numerical modeling framework for simulating extreme storm events was established using the Weather Research and Forecasting (WRF) model. Such a framework is necessary for the derivation of engineering parameters such as probable maximum precipitation that are the cornerstone of large water management infrastructure design. Here this framework was built based on a heavy storm that occurred in Nashville (USA) in 2010, and verified using two other extreme storms. To achieve the optimal setup, several combinations of model resolutions, initial/boundary conditions (IC/BC), cloud microphysics and cumulus parameterization schemes were evaluated using multiple metrics of precipitation characteristics. Themore » evaluation suggests that WRF is most sensitive to IC/BC option. Simulation generally benefits from finer resolutions up to 5 km. At the 15km level, NCEP2 IC/BC produces better results, while NAM IC/BC performs best at the 5km level. Recommended model configuration from this study is: NAM or NCEP2 IC/BC (depending on data availability), 15km or 15km-5km nested grids, Morrison microphysics and Kain-Fritsch cumulus schemes. Validation of the optimal framework suggests that these options are good starting choices for modeling extreme events similar to the test cases. This optimal framework is proposed in response to emerging engineering demands of extreme storm events forecasting and analyses for design, operations and risk assessment of large water infrastructures.« less
A Novel Electro Conductive Graphene/Silicon-Dioxide Thermo-Electric Generator
NASA Astrophysics Data System (ADS)
Rahman, Ataur; Abdi, Yusuf
2017-03-01
Thermoelectric generators are all solid-state devices that convert heat energy into electrical energy. The total energy (fuel) supplied to the engine, approximately 30 to 40% is converted into useful mechanical work; whereas the remaining is expelled to the environment as heat through exhaust gases and cooling systems, resulting in serious green house gas (GHG) emission. By converting waste energy into electrical energy is the aim of this manuscript. The technologies reported on waste heat recovery from exhaust gas of internal combustion engines (ICE) are thermo electric generators (TEG) with finned type, Rankine cycle (RC) and Turbocharger. This paper has presented an electro-conductive graphene oxide/silicon-dioxide (GO-SiO2) composite sandwiched by phosphorus (P) and boron (B) doped silicon (Si) TEG to generate electricity from the IC engine exhaust heat. Air-cooling and liquid cooling techniques adopted conventional TEG module has been tested individually for the electricity generation from IC engine exhausts heat at engine speed of 1000-3000rpm. For the engine speed of 7000 rpm, the maximum voltage was recorded as 1.12V and 4.00V for the air-cooling and liquid cooling respectively. The GO-SiO2 simulated result shows that it’s electrical energy generation is about 80% more than conventional TEG for the exhaust temperature of 500°C. The GO-SiO2 composite TEG develops 524W to 1600W at engine speed 1000 to 5000 rpm, which could contribute to reduce the 10-12% of engine total fuel consumption and improve emission level by 20%.
Instantaneous flywheel torque of IC engine grey-box identification
NASA Astrophysics Data System (ADS)
Milašinović, A.; Knežević, D.; Milovanović, Z.; Škundrić, J.
2018-01-01
In this paper a mathematical model developed for the identification of excitation torque acting on the IC engine flywheel is presented. The excitation torque gained through internal combustion of the fuel in the IC engine is transmitted from the flywheel to the transmission. The torque is not constant but variable and is a function of the crank angle. The verification of the mathematical model was done on a 4-cylinder 4-stroke diesel engine for which the in-cylinder pressure was measured in one cylinder and the instantaneous angular speed of the crankshaft at its free end. The research was conducted on a hydraulic engine brake. Inertial forces of all rotational parts, from flywheel to the turbine wheel of the engine brake, are acting on the flywheel due to the nonuniform motion of the flywheel. It is known from the theory of turbomachinery that the torque on the hydraulic brake is a quadratic function of angular speed. Due to that and the variable angular speed of the turbine wheel of the engine brake, the torque during one engine cycle is also variable. The motivation for this research was the idea (intention) to determine the instantaneous torque acting on the flywheel as a function of the crank angle with a mathematical model without any measuring and based on this to determine the quality of work of specific cylinders of the multi-cylinder engine. The crankshaft was considered elastic and also its torsional vibrations were taken into account.
NASA Space Engineering Research Center for VLSI System Design
NASA Technical Reports Server (NTRS)
1993-01-01
This annual report outlines the activities of the past year at the NASA SERC on VLSI Design. Highlights for this year include the following: a significant breakthrough was achieved in utilizing commercial IC foundries for producing flight electronics; the first two flight qualified chips were designed, fabricated, and tested and are now being delivered into NASA flight systems; and a new technology transfer mechanism has been established to transfer VLSI advances into NASA and commercial systems.
Ni3Al-based alloys for die and tool application
Liu, Chain T.; Bloom, Everett E.
2001-01-01
A novel Ni.sub.3 Al-based alloy exhibits strengths and hardness in excess of the standard base alloy IC-221M at temperatures of up to about 1000.degree. C. The alloy is useful in tool and die applications requiring such temperatures, and for structural elements in engineering systems exposed to such temperatures.
CARMENES. IV: instrument control software
NASA Astrophysics Data System (ADS)
Guàrdia, Josep; Colomé, Josep; Ribas, Ignasi; Hagen, Hans-Jürgen; Morales, Rafael; Abril, Miguel; Galadí-Enríquez, David; Seifert, Walter; Sánchez Carrasco, Miguel A.; Quirrenbach, Andreas; Amado, Pedro J.; Caballero, Jose A.; Mandel, Holger
2012-09-01
The overall purpose of the CARMENES instrument is to perform high-precision measurements of radial velocities of late-type stars with long-term stability. CARMENES will be installed in 2014 at the 3.5 m telescope in the German- Spanish Astronomical Center at Calar Alto observatory (CAHA, Spain) and will be equipped with two spectrographs in the near-infrared and visible windows. The technology involved in such instrument represents a challenge at all levels. The instrument coordination and management is handled by the Instrument Control System (ICS), which is responsible of carrying out the operations of the different subsystems and providing a tool to operate the instrument from low to high user interaction level. The main goal of the ICS and the CARMENES control layer architecture is to maximize the instrument efficiency by reducing time overheads and by operating it in an integrated manner. The ICS implements the CARMENES operational design. A description of the ICS architecture and the application programming interfaces for low- and high-level communication is given. Internet Communications Engine is the technology selected to implement most of the interface protocols.
1964-12-01
This photograph shows the fuel tank assembly for the Saturn V S-IC (first) stage being transported to the Marshall Space Flight Center, building 4705 for mating to the liquid oxygen (LOX) tank. The fuel tank carried kerosene (RP-1) as its fuel. The S-IC stage used five F-1 engines, that used kerosene and liquid oxygen as propellant and each engine provided 1,500,000 pounds of thrust. This stage lifted the entire vehicle and Apollo spacecraft from the launch pad.
1967-07-28
This photograph depicts a view of the test firing of all five F-1 engines for the Saturn V S-IC test stage at the Marshall Space Flight Center. The S-IC stage is the first stage, or booster, of a 364-foot long rocket that ultimately took astronauts to the Moon. Operating at maximum power, all five of the engines produced 7,500,000 pounds of thrust. The S-IC Static Test Stand was designed and constructed with the strength of hundreds of tons of steel and cement, planted down to bedrock 40 feet below ground level, and was required to hold down the brute force of the 7,500,000-pound thrust. The structure was topped by a crane with a 135-foot boom. With the boom in the up position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. When the Saturn V S-IC first stage was placed upright in the stand , the five F-1 engine nozzles pointed downward on a 1,900-ton, water-cooled deflector. To prevent melting damage, water was sprayed through small holes in the deflector at the rate 320,000 gallons per minutes
1965-05-01
This photograph depicts a view of the test firing of all five F-1 engines for the Saturn V S-IC test stage at the Marshall Space Flight Center. The S-IC stage is the first stage, or booster, of a 364-foot long rocket that ultimately took astronauts to the Moon. Operating at maximum power, all five of the engines produced 7,500,000 pounds of thrust. The S-IC Static Test Stand was designed and constructed with the strength of hundreds of tons of steel and cement, planted down to bedrock 40 feet below ground level, and was required to hold down the brute force of the 7,500,000-pound thrust. The structure was topped by a crane with a 135-foot boom. With the boom in the up position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. When the Saturn V S-IC first stage was placed upright in the stand , the five F-1 engine nozzles pointed downward on a 1,900-ton, water-cooled deflector. To prevent melting damage, water was sprayed through small holes in the deflector at the rate 320,000 gallons per minutes.
Jatana, Gurneesh; Geckler, Sam; Koeberlein, David; ...
2016-09-01
We designed and developed a 4-probe multiplexed multi-species absorption spectroscopy sensor system for gas property measurements on the intake side of commercial multi-cylinder internal-combustion (I.C.) engines; the resulting cycle- and cylinder-resolved concentration, temperature and pressure measurements are applicable for assessing spatial and temporal variations in the recirculated exhaust gas (EGR) distribution at various locations along the intake gas path, which in turn is relevant to assessing cylinder charge uniformity, control strategies, and CFD models. Furthermore, the diagnostic is based on absorption spectroscopy and includes an H 2O absorption system (utilizing a 1.39 m distributed feedback (DFB) diode laser) for measuringmore » gas temperature, pressure, and H 2O concentration, and a CO 2 absorption system (utilizing a 2.7 m DFB laser) for measuring CO 2 concentration. The various lasers, optical components and detectors were housed in an instrument box, and the 1.39- m and 2.7- m lasers were guided to and from the engine-mounted probes via optical fibers and hollow waveguides, respectively. The 5kHz measurement bandwidth allows for near-crank angle resolved measurements, with a resolution of 1.2 crank angle degrees at 1000 RPM. Our use of compact stainless steel measurement probes enables simultaneous multi-point measurements at various locations on the engine with minimal changes to the base engine hardware; in addition to resolving large-scale spatial variations via simultaneous multi-probe measurements, local spatial gradients can be resolved by translating individual probes. Along with details of various sensor design features and performance, we also demonstrate validation of the spectral parameters of the associated CO 2 absorption transitions using both a multi-pass heated cell and the sensor probes.« less
Four Pillars of Service-Oriented Architecture
2007-09-01
ic A lig n m e n t Figure 1: Pillars of SOA-Based Systems Development Service -Oriented Architectures 12 CROSSTALK The Journal of Defense Software ...et al. “On the Business Value and Technical Challenges of Adopting Web Services .” Journal of Software Maintenance and Evolution 16 (2004): 16, 31-50...10 CROSSTALK The Journal of Defense Software Engineering September 2007 Acornerstone of DoD policy forfuture software and systems policy is the
1966-01-01
Engineers and technicians at the Marshall Space Flight Center placed a Saturn V ground test booster (S-IC-D) into the dynamic test stand. The stand was constructed to test the integrity of the vehicle. Forces were applied to the tail of the vehicle to simulate the engines thrusting, and various other flight factors were fed to the vehicle to test reactions. The Saturn V launch vehicle, with the Apollo spacecraft, was subjected to more than 450 hours of shaking. The photograph shows the 300,000 pound S-IC stage being lifted from its transporter into place inside the 360-foot tall test stand. This dynamic test booster has one dummy F-1 engine and weight simulators are used at the other four engine positions.
1964-12-01
The fuel tank assembly of the Saturn V S-IC (first) stage supported with the aid of a C frame on the transporter was readied to be transported to the Marshall Space Flight Center, building 4705. The fuel tank carried kerosene (RP-1) as its fuel. The S-IC stage utilized five F-1 engines that used kerosene and liquid oxygen as propellant and each engine provided 1,500,000 pounds of thrust. This stage lifted the entire vehicle and Apollo spacecraft from the launch pad.
1964-12-01
This photograph shows how the fuel tank assembly and the liquid oxygen tank for the Saturn V S-IC (first) stage are placed side by side prior to commencement of the mating of the two stages in the Marshall Space Flight Center, building 4705. The fuel tank carried kerosene as its fuel. The S-IC stage used five F-1 engines, that used kerosene and liquid oxygen as propellant and each engine provided 1,500,000 pounds of thrust. This stage lifted the entire vehicle and Apollo spacecraft from the launch pad.
Real-time diagnostics for a reusable rocket engine
NASA Technical Reports Server (NTRS)
Guo, T. H.; Merrill, W.; Duyar, A.
1992-01-01
A hierarchical, decentralized diagnostic system is proposed for the Real-Time Diagnostic System component of the Intelligent Control System (ICS) for reusable rocket engines. The proposed diagnostic system has three layers of information processing: condition monitoring, fault mode detection, and expert system diagnostics. The condition monitoring layer is the first level of signal processing. Here, important features of the sensor data are extracted. These processed data are then used by the higher level fault mode detection layer to do preliminary diagnosis on potential faults at the component level. Because of the closely coupled nature of the rocket engine propulsion system components, it is expected that a given engine condition may trigger more than one fault mode detector. Expert knowledge is needed to resolve the conflicting reports from the various failure mode detectors. This is the function of the diagnostic expert layer. Here, the heuristic nature of this decision process makes it desirable to use an expert system approach. Implementation of the real-time diagnostic system described above requires a wide spectrum of information processing capability. Generally, in the condition monitoring layer, fast data processing is often needed for feature extraction and signal conditioning. This is usually followed by some detection logic to determine the selected faults on the component level. Three different techniques are used to attack different fault detection problems in the NASA LeRC ICS testbed simulation. The first technique employed is the neural network application for real-time sensor validation which includes failure detection, isolation, and accommodation. The second approach demonstrated is the model-based fault diagnosis system using on-line parameter identification. Besides these model based diagnostic schemes, there are still many failure modes which need to be diagnosed by the heuristic expert knowledge. The heuristic expert knowledge is implemented using a real-time expert system tool called G2 by Gensym Corp. Finally, the distributed diagnostic system requires another level of intelligence to oversee the fault mode reports generated by component fault detectors. The decision making at this level can best be done using a rule-based expert system. This level of expert knowledge is also implemented using G2.
1964-01-01
This close-up view of the F-1 engine for the Saturn V S-IC (first) stage shows the engine's complexity, and also its large size as it dwarfs the technician. Developed by Rocketdyne, under the direction of the Marshall Space Flight Center, the F-1 engine was utilized in a cluster of five engines to propel the Saturn V's first stage, the S-IC. Liquid oxygen and kerosene were used as its propellant. Initially rated at 1,500,000 pounds of thrust, the engine was later uprated to 1,522,000 pounds of thrust after the third Saturn V launch (Apollo 8, the first marned Saturn V mission) in December 1968. The cluster of five F-1 engines burned over 15 tons of propellant per second, during its two and one-half minutes of operation, to take the vehicle to a height of about 36 miles and to a speed of about 6,000 miles per hour.
1963-01-01
A close-up view of the F-1 Engine for the Saturn V S-IC (first) stage depicts the complexity of the engine. Developed by Rocketdyne under the direction of the Marshall Space Flight Center, the F-1 engine was utilized in a cluster of five engines to propel the Saturn V's first stage, the S-IC. Liquid oxygen and kerosene were used as its propellant. Initially rated at 1,500,000 pounds of thrust, the engine was later uprated to 1,522,000 pounds of thrust after the third Saturn V launch (Apollo 8, the first marned Saturn V mission) in December 1968. The cluster of five F-1 engines burned over 15 tons of propellant per second, during its two and one-half minutes of operation, to take the vehicle to a height of about 36 miles and to a speed of about 6,000 miles per hour.
A System Architecture to Support a Verifiably Secure Multilevel Security System.
1980-06-01
4] Newmann, P.G., R. Fabry, K. Levitt, L. Robin - provide a tradeoff between cost and system secur- son, J. Wensley , "On the Design of a Provably ity...ICS-80/05 NL 112. 11W1 --1.25 1111 6 Mli,’O~ll Rl OIIION W AII .q3 0 School of Information and Computer Science S =GEORGIA INSTITUTE OF TECHNOLOGY 808...Multilevel Security Systemt (Extended Abstract) George I. Davida Department of Electical Engineering and Computer Science University of Wisconsin
The application of S-transformation and M-2DPCA in I.C. Engine fault diagnosis
NASA Astrophysics Data System (ADS)
Zhang, Shixiong; Cai, Yanping; Mu, Weijie
2017-04-01
According to the problem of parameter selection and feature extraction for vibration diagnosis of traditional internal combustion engine is discussed. The method based on S-transformation and Module Two Dimensional Principal Components Analysis (M-2DPCA) is proposed to carry out fault diagnosis of I.C. Engine valve mechanism. First of all, the method transfers cylinder surface vibration signals of I.C. into images through S-transform. The second, extracting the optimized projection vectors from the general distribution matrix G which is obtained by all sample sub-images, so that vibration spectrum images can be modularized using M-2DPCA. The last, these features matrix obtained from images project will served as the enters of nearest neighbor classifier, it is used to achieve fault types' division. The method is applied to the diagnosis example of the vibration signal of the valve mechanism eight operating modes, recognition rate up to 94.17 percent; the effectiveness of the proposed method is proved.
I.C. Engine emission reduction by copper oxide catalytic converter
NASA Astrophysics Data System (ADS)
Venkatesan, S. P.; Shubham Uday, Desai; Karan Hemant, Borana; Rajarshi Kushwanth Goud, Kagita; Lakshmana Kumar, G.; Pavan Kumar, K.
2017-05-01
The toxic gases emitted from diesel engines are more than petrol engines. Predicting the use of diesel engines, even more in future, this system is developed and can be used to minimize the harmful gases. Toxic gases include NOX, CO, HC and Smoke which are harmful to the atmosphere as well as to the human beings. The main aim of this work is to fabricate system, where the level of intensity of toxic gases is controlled through chemical reaction to more agreeable level. This system acts itself as an exhaust system; hence there is no needs to fit separate the silencer. The whole assembly is fitted in the exhaust pipe from engine. In this work, catalytic converter with copper oxide as a catalyst, by replacing noble catalysts such as platinum, palladium and rhodium is fabricated and fitted in the engine exhaust. With and without catalytic converter, the experimentations are carried out at different loads such as 0%, 25%, 50%, 75%, and 100% of maximum rated load. From the experimental results it is found that the maximum reduction is 32%, 61% and 21% for HC, NOx and CO respectively at 100% of maximum rated load when compared to that of without catalytic converter. This catalytic converter system is cash effective and more economical than the existing catalytic converter.
Intelligent controller of novel design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou Qi Jian; Bai Jian Kuo
1983-01-01
This paper presents the authors attempt to combine the control engineering principle with human intelligence to form a new control algorithm. The hybrid system thus formed is both analogous and logical in actions and is called the intelligent controller (IC). With the help of cybernetics princple, the operator's intelligent action of control is programmed into the controller and the system is thus taught to act like an intelligent being within the prescribed range. Remarkable results were obtained from experiments conducted on an electronic model simulating the above mentioned system. Stability studies and system analysis are presented. 12 references.
Dr. von Braun Standing by Five F-1 Engines
NASA Technical Reports Server (NTRS)
2004-01-01
A pioneer of America's space program, Dr. von Braun stands by the five F-1 engines of the Saturn V launch vehicle. This Saturn V vehicle is an actual test vehicle which has been displayed at the U.S. Space Rocket Center in Huntsville, Alabama. Designed and developed by Rocketdyne under the direction of the Marshall Space Flight Center, a cluster of five F-1 engines was mounted on the Saturn V S-IC (first) stage. The engines measured 19-feet tall by 12.5-feet at the nozzle exit and burned 15 tons of liquid oxygen and kerosene each second to produce 7,500,000 pounds of thrust. The S-IC stage is the first stage, or booster, of a 364-foot long rocket that ultimately took astronauts to the Moon.
A generalized sizing method for revolutionary concepts under probabilistic design constraints
NASA Astrophysics Data System (ADS)
Nam, Taewoo
Internal combustion (IC) engines that consume hydrocarbon fuels have dominated the propulsion systems of air-vehicles for the first century of aviation. In recent years, however, growing concern over rapid climate changes and national energy security has galvanized the aerospace community into delving into new alternatives that could challenge the dominance of the IC engine. Nevertheless, traditional aircraft sizing methods have significant shortcomings for the design of such unconventionally powered aircraft. First, the methods are specialized for aircraft powered by IC engines, and thus are not flexible enough to assess revolutionary propulsion concepts that produce propulsive thrust through a completely different energy conversion process. Another deficiency associated with the traditional methods is that a user of these methods must rely heavily on experts' experience and advice for determining appropriate design margins. However, the introduction of revolutionary propulsion systems and energy sources is very likely to entail an unconventional aircraft configuration, which inexorably disqualifies the conjecture of such "connoisseurs" as a means of risk management. Motivated by such deficiencies, this dissertation aims at advancing two aspects of aircraft sizing: (1) to develop a generalized aircraft sizing formulation applicable to a wide range of unconventionally powered aircraft concepts and (2) to formulate a probabilistic optimization technique that is able to quantify appropriate design margins that are tailored towards the level of risk deemed acceptable to a decision maker. A more generalized aircraft sizing formulation, named the Architecture Independent Aircraft Sizing Method (AIASM), was developed for sizing revolutionary aircraft powered by alternative energy sources by modifying several assumptions of the traditional aircraft sizing method. Along with advances in deterministic aircraft sizing, a non-deterministic sizing technique, named the Probabilistic Aircraft Sizing Method (PASM), was developed. The method allows one to quantify adequate design margins to account for the various sources of uncertainty via the application of the chance-constrained programming (CCP) strategy to AIASM. In this way, PASM can also provide insights into a good compromise between cost and safety.
First imaging Fourier-transform spectral measurements of detonation in an internal combustion engine
NASA Astrophysics Data System (ADS)
Gross, Kevin C.; Borel, Chris; White, Allen; Sakai, Stephen; DeVasher, Rebecca; Perram, Glen P.
2010-08-01
The Telops Hyper-Cam midwave (InSb 1.5-5.5μm) imaging Fourier-transformspectrometer (IFTS) observed repeated detonations in an ethanol-powered internal combustion (IC) engine. The IC engine is aMegatech Corporation MEG 150 with a 1in. bore, 4in. stroke, and a compression ratio of 3 : 1. The IC combustion cylinder is made from sapphire permitting observation in the visible and infrared. From a distance of 3m, the IFTS imaged the combustion cylinder on a 64×32 pixel array with each pixel covering a 0.1×0.1cm2 area. More than 14,000 interferograms were collected at a rate of 16Hz. The maximum optical path difference of the interferograms was 0.017cm corresponding to an unapodized spectral resolution of 36cm-1. Engine speed was varied between 600-1200RPM to de-correlate the observation time scale from the occurrence of detonations. A method is devised to process the ensemble of interferograms which takes advantage of the DC component so that the time history of the combustion spectrum can be recovered at each pixel location. Preliminary results of this analysis will be presented.
An overview of NASA intermittent combustion engine research
NASA Technical Reports Server (NTRS)
Willis, E. A.; Wintucky, W. T.
1984-01-01
This paper overviews the current program, whose objective is to establish the generic technology base for advanced aircraft I.C. engines of the early 1990's and beyond. The major emphasis of this paper is on development of the past two years. Past studies and ongoing confirmatory experimental efforts are reviewed, which show unexpectedly high potential when modern aerospace technologies are applied to inherently compact and balanced I.C. engine configurations. Currently, the program is focussed on two engine concepts, the stratified-charge, multi-fuel rotary and the lightweight two-stroke diesel. A review is given of contracted and planned high performance one-rotor and one-cylinder test engine work addressing several levels of technology. Also reviewed are basic supporting efforts, e.g., the development and experimental validation of computerized airflow and combustion process models, being performed in-house at Lewis Research Center and by university grants. Previously announced in STAR as N84-24583
An overview of NASA intermittent combustion engine research
NASA Technical Reports Server (NTRS)
Willis, E. A.; Wintucky, W. T.
1984-01-01
This paper overviews the current program, whose objective is to establish the generic technology base for advanced aircraft I.C. engines of the early 1990's and beyond. The major emphasis of this paper is on development of the past two years. Past studies and ongoing confirmatory experimental efforts are reviewed, which show unexpectly high potential when modern aerospace technologies are applied to inherently compact and balanced I.C. engine configurations. Currently, the program is focussed on two engine concepts the stratified-charge, multi-fuel rotary, and the lightweight two-stroke diesel. A review is given of contracted and planned high performance one-rotor and one-cylinder test engine work addressing several levels of technology. Also reviewed are basic supporting efforts, e.g., the development and experimental validation of computerized airflow and combustion process models, being performed in-house at Lewis Research Center and by university grants.
Defense Small Business Innovation Research Program (SBIR). Abstracts of Phase 2 Awards 1992
1992-01-01
tV:iiisatuir packace. and 12 MNI IC itiphefilInciaiiti itl o threebitdpstier lAP RI .Sl:ARCI I INC I-opte#.1ý" M 1 )25 II0& X144RI Ali! 27()3 (U lAIR ...achieve high gain in a refraction - or nonuniformity -compensated, twin-target system, and construct a portable x-ray laser engineering prototype. This
2014-09-01
biometrics technologies. 14. SUBJECT TERMS Facial recognition, systems engineering, live video streaming, security cameras, national security ...national security by sharing biometric facial recognition data in real-time utilizing infrastructures currently in place. It should be noted that the...9/11),law enforcement (LE) and Intelligence community (IC)authorities responsible for protecting citizens from threats against national security
Initiative in Concurrent Engineering (DICE). Phase 1.
1990-02-09
and power of commercial and military electronics systems. The continual evolution of HDE technology offers far greater flexibility in circuit design... powerful magnetic field of the permanent magnets in the sawyer motors. This makes it possible to have multiple robots in the workcell and to have them...Controller. The Adept IC was chosen because of its extensive processing power , integrated grayscale vision, standard 28 industrial I/O control
NASA Astrophysics Data System (ADS)
Kulas, M.; Borelli, Jose Luis; Gässler, Wolfgang; Peter, Diethard; Rabien, Sebastian; Orban de Xivry, Gilles; Busoni, Lorenzo; Bonaglia, Marco; Mazzoni, Tommaso; Rahmer, Gustavo
2014-07-01
Commissioning time for an instrument at an observatory is precious, especially the night time. Whenever astronomers come up with a software feature request or point out a software defect, the software engineers have the task to find a solution and implement it as fast as possible. In this project phase, the software engineers work under time pressure and stress to deliver a functional instrument control software (ICS). The shortness of development time during commissioning is a constraint for software engineering teams and applies to the ARGOS project as well. The goal of the ARGOS (Advanced Rayleigh guided Ground layer adaptive Optics System) project is the upgrade of the Large Binocular Telescope (LBT) with an adaptive optics (AO) system consisting of six Rayleigh laser guide stars and wavefront sensors. For developing the ICS, we used the technique Test- Driven Development (TDD) whose main rule demands that the programmer writes test code before production code. Thereby, TDD can yield a software system, that grows without defects and eases maintenance. Having applied TDD in a calm and relaxed environment like office and laboratory, the ARGOS team has profited from the benefits of TDD. Before the commissioning, we were worried that the time pressure in that tough project phase would force us to drop TDD because we would spend more time writing test code than it would be worth. Despite this concern at the beginning, we could keep TDD most of the time also in this project phase This report describes the practical application and performance of TDD including its benefits, limitations and problems during the ARGOS commissioning. Furthermore, it covers our experience with pair programming and continuous integration at the telescope.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korsah, K.
This document (1) summarizes the most significant findings of the ''Qualification of Advanced Instrumentation and Control (I&C) Systems'' program initiated by the Nuclear Regulatory Commission (NRC); (2) documents a comparative analysis of U.S. and European qualification standards; and (3) provides recommendations for enhancing regulatory guidance for environmental qualification of microprocessor-based safety-related systems. Safety-related I&C system upgrades of present-day nuclear power plants, as well as I&C systems of Advanced Light-Water Reactors (ALWRs), are expected to make increasing use of microprocessor-based technology. The Nuclear Regulatory Commission (NRC) recognized that the use of such technology may pose environmental qualification challenges different from current,more » analog-based I&C systems. Hence, it initiated the ''Qualification of Advanced Instrumentation and Control Systems'' program. The objectives of this confirmatory research project are to (1) identify any unique environmental-stress-related failure modes posed by digital technologies and their potential impact on the safety systems and (2) develop the technical basis for regulatory guidance using these findings. Previous findings from this study have been documented in several technical reports. This final report in the series documents a comparative analysis of two environmental qualification standards--Institute of Electrical and Electronics Engineers (IEEE) Std 323-1983 and International Electrotechnical Commission (IEC) 60780 (1998)--and provides recommendations for environmental qualification of microprocessor-based systems based on this analysis as well as on the findings documented in the previous reports. The two standards were chosen for this analysis because IEEE 323 is the standard used in the U.S. for the qualification of safety-related equipment in nuclear power plants, and IEC 60780 is its European counterpart. In addition, the IEC document was published in 1998, and should reflect any new qualification concerns, from the European perspective, with regard to the use of microprocessor-based safety systems in power plants.« less
DOT National Transportation Integrated Search
2009-02-01
The main objective of this project was to develop instructional engineering projects that utilize the newly-offered PACE software GT-POWER for engine simulations in combustion-related courses at the Missouri University of Science and Technology. Stud...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Satogata, Todd
2013-04-22
The integrated control system (ICS) is responsible for the whole ESS machine and facility: accelerator, target, neutron scattering instruments and conventional facilities. This unified approach keeps the costs of development, maintenance and support relatively low. ESS has selected a standardised, field-proven controls framework, the Experimental Physics and Industrial Control System (EPICS), which was originally developed jointly by Argonne and Los Alamos National Laboratories. Complementing this selection are best practices and experience from similar facilities regarding platform standardisation, control system development and device integration and commissioning. The components of ICS include the control system core, the control boxes, the BLED databasemore » management system, and the human machine interface. The control system core is a set of systems and tools that make it possible for the control system to provide required data, information and services to engineers, operators, physicists and the facility itself. The core components are the timing system that makes possible clock synchronisation across the facility, the machine protection system (MPS) and the personnel protection system (PPS) that prevent damage to the machine and personnel, and a set of control system services. Control boxes are servers that control a collection of equipment (for example a radio frequency cavity). The integrated control system will include many control boxes that can be assigned to one supplier, such as an internal team, a collaborating institute or a commercial vendor. This approach facilitates a clear division of responsibilities and makes integration much easier. A control box is composed of a standardised hardware platform, components, development tools and services. On the top level, it interfaces with the core control system components (timing, MPS, PPS) and with the human-machine interface. At the bottom, it interfaces with the equipment and parts of the facility through a set of analog and digital signals, real-time control loops and other communication buses. The ICS central data management system is named BLED (beam line element databases). BLED is a set of databases, tools and services that is used to store, manage and access data. It holds vital control system configuration and physics-related (lattice) information about the accelerator, target and instruments. It facilitates control system configuration by bringing together direct input-output controller (IOC) con guration and real-time data from proton and neutron beam line models. BLED also simplifies development and speeds up the code-test-debug cycle. The set of tools that access BLED will be tailored to the needs of different categories of users, such as ESS staff physicists, engineers, and operators; external partner laboratories; and visiting experimental instrument users. The human-machine interface is vital to providing a high-quality experience to ICS users. It encompasses a wide array of devices and software tools, from control room screens to engineer terminal windows; from beam physics data tools to post-mortem data analysis tools. It serves users with a wide range of skills from widely varied backgrounds. The Controls Group is developing a set of user profiles to accommodate this diverse range of use-cases and users.« less
Cyber Security Testing and Training Programs for Industrial Control Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel Noyes
2012-03-01
Service providers rely on industrial control systems (ICS) to manage the flow of water at dams, open breakers on power grids, control ventilation and cooling in nuclear power plants, and more. In today's interconnected environment, this can present a serious cyber security challenge. To combat this growing challenge, government, private industry, and academia are working together to reduce cyber risks. The Idaho National Laboratory (INL) is a key contributor to the Department of Energy National SCADA Test Bed (NSTB) and the Department of Homeland Security (DHS) Control Systems Security Program (CSSP), both of which focus on improving the overall securitymore » posture of ICS in the national critical infrastructure. In support of the NSTB, INL hosts a dedicated SCADA testing facility which consists of multiple control systems supplied by leading national and international manufacturers. Within the test bed, INL researchers systematically examine control system components and work to identify vulnerabilities. In support of the CSSP, INL develops and conducts training courses which are designed to increase awareness and defensive capabilities for IT/Control System professionals. These trainings vary from web-based cyber security trainings for control systems engineers to more advanced hands-on training that culminates with a Red Team/ Blue Team exercise that is conducted within an actual control systems environment. INL also provides staffing and operational support to the DHS Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) Security Operations Center which responds to and analyzes control systems cyber incidents across the 18 US critical infrastructure sectors.« less
Detecting Payload Attacks on Programmable Logic Controllers (PLCs)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Huan
Programmable logic controllers (PLCs) play critical roles in industrial control systems (ICS). Providing hardware peripherals and firmware support for control programs (i.e., a PLC’s “payload”) written in languages such as ladder logic, PLCs directly receive sensor readings and control ICS physical processes. An attacker with access to PLC development software (e.g., by compromising an engineering workstation) can modify the payload program and cause severe physical damages to the ICS. To protect critical ICS infrastructure, we propose to model runtime behaviors of legitimate PLC payload program and use runtime behavior monitoring in PLC firmware to detect payload attacks. By monitoring themore » I/O access patterns, network access patterns, as well as payload program timing characteristics, our proposed firmware-level detection mechanism can detect abnormal runtime behaviors of malicious PLC payload. Using our proof-of-concept implementation, we evaluate the memory and execution time overhead of implementing our proposed method and find that it is feasible to incorporate our method into existing PLC firmware. In addition, our evaluation results show that a wide variety of payload attacks can be effectively detected by our proposed approach. The proposed firmware-level payload attack detection scheme complements existing bumpin- the-wire solutions (e.g., external temporal-logic-based model checkers) in that it can detect payload attacks that violate realtime requirements of ICS operations and does not require any additional apparatus.« less
Unveiling the AGN in IC 883: discovery of a parsec-scale radio jet
NASA Astrophysics Data System (ADS)
Romero-Cañizales, C.; Alberdi, A.; Ricci, C.; Arévalo, P.; Pérez-Torres, M. Á.; Conway, J. E.; Beswick, R. J.; Bondi, M.; Muxlow, T. W. B.; Argo, M. K.; Bauer, F. E.; Efstathiou, A.; Herrero-Illana, R.; Mattila, S.; Ryder, S. D.
2017-05-01
IC 883 is a luminous infrared galaxy (LIRG) classified as a starburst-active galactic nucleus (AGN) composite. In a previous study, we detected a low-luminosity AGN (LLAGN) radio candidate. Here, we report on our radio follow-up at three frequencies that provides direct and unequivocal evidence of the AGN activity in IC 883. Our analysis of archival X-ray data, together with the detection of a transient radio source with luminosity typical of bright supernovae, gives further evidence of the ongoing star formation activity, which dominates the energetics of the system. At sub-parsec scales, the radio nucleus has a core-jet morphology with the jet being a newly ejected component showing a subluminal proper motion of 0.6-1 c. The AGN contributes less than 2 per cent of the total IR luminosity of the system. The corresponding Eddington factor is ˜10-3, suggesting this is a low-accretion rate engine, as often found in LLAGNs. However, its high bolometric luminosity (˜1044 erg s-1) agrees better with a normal AGN. This apparent discrepancy may just be an indication of the transition nature of the nucleus from a system dominated by star formation, to an AGN-dominated system. The nucleus has a strongly inverted spectrum and a turnover at ˜4.4 GHz, thus qualifying as a candidate for the least luminous (L5.0 GHz ˜ 6.3 × 1028 erg s-1 Hz-1) and one of the youngest (˜3 × 103 yr) gigahertz-peaked spectrum (GPS) sources. If the GPS origin for the IC 883 nucleus is confirmed, then advanced mergers in the LIRG category are potentially key environments to unveil the evolution of GPS sources into more powerful radio galaxies.
2004-04-15
A pioneer of America's space program, Dr. von Braun stands by the five F-1 engines of the Saturn V launch vehicle. This Saturn V vehicle is an actual test vehicle which has been displayed at the U.S. Space Rocket Center in Huntsville, Alabama. Designed and developed by Rocketdyne under the direction of the Marshall Space Flight Center, a cluster of five F-1 engines was mounted on the Saturn V S-IC (first) stage. The engines measured 19-feet tall by 12.5-feet at the nozzle exit and burned 15 tons of liquid oxygen and kerosene each second to produce 7,500,000 pounds of thrust. The S-IC stage is the first stage, or booster, of a 364-foot long rocket that ultimately took astronauts to the Moon.
Software Engineering Laboratory (SEL) cleanroom process model
NASA Technical Reports Server (NTRS)
Green, Scott; Basili, Victor; Godfrey, Sally; Mcgarry, Frank; Pajerski, Rose; Waligora, Sharon
1991-01-01
The Software Engineering Laboratory (SEL) cleanroom process model is described. The term 'cleanroom' originates in the integrated circuit (IC) production process, where IC's are assembled in dust free 'clean rooms' to prevent the destructive effects of dust. When applying the clean room methodology to the development of software systems, the primary focus is on software defect prevention rather than defect removal. The model is based on data and analysis from previous cleanroom efforts within the SEL and is tailored to serve as a guideline in applying the methodology to future production software efforts. The phases that are part of the process model life cycle from the delivery of requirements to the start of acceptance testing are described. For each defined phase, a set of specific activities is discussed, and the appropriate data flow is described. Pertinent managerial issues, key similarities and differences between the SEL's cleanroom process model and the standard development approach used on SEL projects, and significant lessons learned from prior cleanroom projects are presented. It is intended that the process model described here will be further tailored as additional SEL cleanroom projects are analyzed.
Application Of Holography In The Distribution Measurement Of Fuel Spraying Field In Diesel Engines
NASA Astrophysics Data System (ADS)
Xiang, He Wan; Xiong, Li Zhi
1988-01-01
The distribution of fuel spraying field in the combustion chamber is an important factor which influences the performance of diesel engines. Precise data for those major parameters of the spraying field distribution are difficult to obtain using conventional ways of measurement, so its effects on the combustion process cannot be controlled. The laser holographic measurement is used and many researches have been made on the injecting nozzles used in diesel engines Series 95, 100 and 130. These researches show that clear spraying field hologram can be taken with an "IC Engine Laser Holography System". By rendition and data processing, droplet size, amount and their space distribution in the spraying; the spraying range, cone angle and other dependable data can be obtained. Therefore, the spraying quality of an injecting nozzle can be precisely determined, which provides reliable basis for the improvement of diesel engines' functions.
NASA Technical Reports Server (NTRS)
Korsmeyer, David; Schreiner, John
2002-01-01
This technology evaluation report documents the findings and recommendations of the Engineering for Complex Systems Program (formerly Design for Safety) PRACA Enhancement Pilot Study of the Space Shuttle Program's (SSP's) Problem Reporting and Corrective Action (PRACA) System. A team at NASA Ames Research Center (ARC) performed this Study. This Study was initiated as a follow-on to the NASA chartered Shuttle Independent Assessment Team (SIAT) review (performed in the Fall of 1999) which identified deficiencies in the current PRACA implementation. The Pilot Study was launched with an initial qualitative assessment and technical review performed during January 2000 with the quantitative formal Study (the subject of this report) started in March 2000. The goal of the PRACA Enhancement Pilot Study is to evaluate and quantify the technical aspects of the SSP PRACA systems and recommend enhancements to address deficiencies and in preparation for future system upgrades.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DiSalvo, Rick; Surovchak, Scott; Spreng, Carl
2013-07-01
Cleanup and closure of DOE's Rocky Flats Site in Colorado, which was placed on the CERCLA National Priority List in 1989, was accomplished under CERCLA, RCRA, and the Colorado Hazardous Waste Act (CHWA). The physical cleanup work was completed in late 2005 and all buildings and other structures that composed the Rocky Flats industrial complex were removed from the surface, but remnants remain in the subsurface. Other remaining features include two landfills closed in place with covers, four groundwater treatment systems, and surface water and groundwater monitoring systems. Under the 2006 Corrective Action Decision/Record of Decision for Rocky Flats Plantmore » (US DOE) Peripheral Operable Unit and the Central Operable Unit (CAD/ROD), the response actions selected for the Central Operable Unit (OU) are institutional controls (ICs), physical controls, and continued monitoring and maintenance. The objectives of these ICs were to prevent unacceptable exposure to remaining subsurface contamination and to prevent contaminants from mobilizing to surface water and to prevent interfering with the proper functioning of the engineered components of the remedy. An amendment in 2011 of the 2006 CAD/ROD clarified the ICs to prevent misinterpretation that would prohibit work to manage and maintain the Central OU property. The 2011 amendment incorporated a protocol for a Soil Disturbance Review Plan for work subject to ICs that requires approval from the State and public notification by DOE prior to conducting approved soil-disturbing work. (authors)« less
Construction Progress of the S-IC Test Stand Complex Bunker House
NASA Technical Reports Server (NTRS)
1963-01-01
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC stand, additional related facilities were built during this time frame. Built to the east of the S-IC stand, the block house served as the control room. To the south of the blockhouse was a newly constructed pump house used for delivering water to the S-IC stand during testing. North of the massive test stand, the F-1 Engine test stand was built for testing a single F-1 engine. Just southeast of the S-IC stand a concrete bunker house was constructed. The bunker housed an emergency crew clad in fire proof gear, who were close at hand should any emergencies arise during testing. This photo of the completed bunker house was taken on May 7, 1963.
1963-01-14
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC test stand, related facilities were constructed during this time frame. Built just north of the massive S-IC test stand was the F-1 Engine test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken January 14, 1963 depicts the F-1 test stand site with hoses pumping excess water from the site.
1965-03-01
This photograph shows F-1 engines being stored in the F-1 Engine Preparation Shop, building 4666, at the Marshall Space Flight Center. Each F-1 engine produced a thrust of 1,500,000 pounds. A cluster of five engines was mounted on the thrust structure of the S-IC stage of a 364-foot long Saturn V launch vehicle that ultimately took astronauts to the Moon.
1963-11-20
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo shows the progress of the F-1 Test Stand as of November 20, 1963.
1962-07-03
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of July 3, 1963. All four of its tower legs are well underway.
1963-04-04
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken April 4, 1963 depicts the construction of the F-1 test stand foundation walls.
1963-04-17
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken April 17, 1963 depicts the construction of the F-1 test stand foundation walls.
1963-09-05
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of September 5, 1963.
1963-09-30
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of September 30, 1963.
1963-06-24
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of June 24, 1963. Two if its four tower legs are underway.
1963-10-22
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Northeast of the massive S-IC test stand, the F-1 Engine test stand was built. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the fuel tanks that housed kerosene and just beyond those is the F-1 test stand.
Engineering study of the rotary-vee engine concept
NASA Technical Reports Server (NTRS)
Willis, Edward A.; Bartrand, Timothy A.; Beard, John E.
1989-01-01
The applicable thermodynamic cycle and performance considerations when the rotary-vee mechanism is used as an internal combustion (I.C.) heat engine are reviewed. Included is a simplified kinematic analysis and studies of the effects of design parameters on the critical pressures, torques and parasitic losses. A discussion of the principal findings is presented.
ERIC Educational Resources Information Center
Byrd, Daniel; Shorette, Rob
2016-01-01
California is at a crossroads in terms of STEM and health workforce development. On the one hand, California has more available entry-level STEM jobs than any other state in the country and a steadily growing health workforce, giving large segments of its population access to stable careers. On the other hand, California's public colleges and…
Insect cells as factories for biomanufacturing.
Drugmand, Jean-Christophe; Schneider, Yves-Jacques; Agathos, Spiros N
2012-01-01
Insect cells (IC) and particularly lepidopteran cells are an attractive alternative to mammalian cells for biomanufacturing. Insect cell culture, coupled with the lytic expression capacity of baculovirus expression vector systems (BEVS), constitutes a powerful platform, IC-BEVS, for the abundant and versatile formation of heterologous gene products, including proteins, vaccines and vectors for gene therapy. Such products can be manufactured on a large scale thanks to the development of efficient and scaleable production processes involving the integration of a cell growth stage and a stage of cell infection with the recombinant baculovirus vector. Insect cells can produce multimeric proteins functionally equivalent to the natural ones and engineered vectors can be used for efficient expression. Insect cells can be cultivated easily in serum- and protein-free media. A growing number of companies are currently developing an interest in producing therapeutics using IC-BEVS, and many products are today in clinical trials and on the market for veterinary and human applications. This review summarizes current knowledge on insect cell metabolism, culture conditions and applications. Copyright © 2011 Elsevier Inc. All rights reserved.
Engineering information on an Analog Signal to Discrete Time Interval Converter (ASDT-IC)
NASA Technical Reports Server (NTRS)
Schwarz, F. C.
1974-01-01
An electronic control system for nondissipative dc power converters is presented which improves (1) the routinely attainable static output voltage accuracy to the order of + or - 1% for ambient temperatures from -55 to 100 C and (2) the dynamic stability by utilizing approximately one tenth of the feedback gain needed otherwise. Performance is due to a functional philosophy of deterministic pulse modulation based on pulse area control and to an autocompensated signal processing principle. The system can be implemented with commercially available unselected components.
Summary of Research, Academic Departments, 1983-1984.
1984-10-01
miagnetoelast ic strain gauiges. hydraulic (ollrols svsteiiis, robotics, aiiol gas tul-ili( engine (lilic(’. Th’lis wear, e’Ii phasis has beent placed...gatige, the( gifligV id~ itsSsigiifI Co(lifltioflihlg. High Level Real-Time Software for Hydraulic Control Systems in Deep Submergence Vehicles h~iSiAt...Simulation of a Hydraulic Control System At )VISUMt: ASSOCIATII PiiOtISSOt1 IAIU IIB V. I I)L SKA\\ Theo Jriluialrv pourpose of’ this l’C51’drch is to) wxIihi
1965-01-01
The Saturn V first stages were test fired at the Mississippi Test Facility and at the Marshall Space Flight Center (MSFC). Five F-1 engines powered the first stage, each developing 1.5 million pounds of thrust. The first stage, known as the S-IC stage, burned over 15 tons of propellant per second during its 2.5 minutes of operation to take the vehicle to a height of about 36 miles and to a speed of about 6,000 miles per hour. The stage was 138 feet long and 33 feet in diameter. This photograph shows the test firing of an F-1 engine at the MSFC's S-IC Static Test Firing Facility.
Laboratory experiments in integrated circuit fabrication
NASA Technical Reports Server (NTRS)
Jenkins, Thomas J.; Kolesar, Edward S.
1993-01-01
The objectives of the experiment are fourfold: to provide practical experience implementing the fundamental processes and technology associated with the science and art of integrated circuit (IC) fabrication; to afford the opportunity for the student to apply the theory associated with IC fabrication and semiconductor device operation; to motivate the student to exercise engineering decisions associated with fabricating integrated circuits; and to complement the theory of n-channel MOS and diffused devices that are presented in the classroom by actually fabricating and testing them. Therefore, a balance between theory and practice can be realized in the education of young engineers, whose education is often criticized as lacking sufficient design and practical content.
Supramolecular Systems Behavior at the Air-Water Interface. Molecular Dynamic Simulation Study.
NASA Astrophysics Data System (ADS)
Sandoval, C.; Saavedra, M.; Gargallo, L.; Radić, D.
2008-08-01
Atomistic molecular dynamics simulation (MDS) was development to investigate the structural and dynamic properties of a monolayer of supramolecular systems. The simulations were performed at room temperature, on inclusion complexes (ICs) of α-cyclodextrin (CD) with poly(ethylene-oxide)(PEO), poly(ɛ-caprolactone)(PEC) and poly(tetrahydrofuran)(PTHF). The simulations were carried out for a surface area of 30Å. The trajectories of the MDS show that the system more stable was IC-PEC, being the less stable IC-PEO. The disordered monolayer for the systems was proved by the orientation correlation function and the radial distribution function between the polar groups of ICs and the water molecules. We found that the system IC-PEC was more stable that the systems IC-PTHF and IC-PEO.
Engineering study on the rotary-vee engine concept
NASA Technical Reports Server (NTRS)
Willis, Edward A.; Bartland, Timothy A.; Beard, John E.
1989-01-01
This paper provides a review of the applicable thermodynamic cycle and performance considerations when the rotary-vee mechanism is used as an internal combustion (IC) heat engine. Included is a simplified kinematic analysis and studies of the effects of design parameters on the critical pressures, torques and parasitic losses. A discussion of the principal findings is presented.
1963-01-15
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. The F-1 Engine test stand was built north of the massive S-IC test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This aerial photograph, taken January 15, 1963, gives a close overall view of the newly developed test complex. Depicted in the forefront center is the S-IC test stand with towers prominent, the Block House is seen in the center just above the S-IC test stand, and the large hole to the left, located midway between the two is the F-1 test stand site.
1963-01-15
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. The F-1 Engine test stand was built north of the massive S-IC test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This aerial photograph, taken January 15, 1963 gives an overall view of the construction progress of the newly developed test complex. The large white building located in the center is the Block House. Just below and to the right of it is the S-IC test stand. The large hole to the left of the S-IC stand is the F-1 test stand site.
NASA Astrophysics Data System (ADS)
Zhong, Donglai; Zhao, Chenyi; Liu, Lijun; Zhang, Zhiyong; Peng, Lian-Mao
2018-04-01
In this letter, we report a gate engineering method to adjust threshold voltage of carbon nanotube (CNT) based field-effect transistors (FETs) continuously in a wide range, which makes the application of CNT FETs especially in digital integrated circuits (ICs) easier. Top-gated FETs are fabricated using solution-processed CNT network films with stacking Pd and Sc films as gate electrodes. By decreasing the thickness of the lower layer metal (Pd) from 20 nm to zero, the effective work function of the gate decreases, thus tuning the threshold voltage (Vt) of CNT FETs from -1.0 V to 0.2 V. The continuous adjustment of threshold voltage through gate engineering lays a solid foundation for multi-threshold technology in CNT based ICs, which then can simultaneously provide high performance and low power circuit modules on one chip.
Tuan, Chia-Chi; James, Nathan Pataki; Lin, Ziyin; Chen, Yun; Liu, Yan; Moon, Kyoung-Sik; Li, Zhuo; Wong, C P
2017-03-15
As microelectronics are trending toward smaller packages and integrated circuit (IC) stacks nowadays, underfill, the polymer composite filled in between the IC chip and the substrate, becomes increasingly important for interconnection reliability. However, traditional underfills cannot meet the requirements for low-profile and fine pitch in high density IC stacking packages. Post-applied underfills have difficulties in flowing into the small gaps between the chip and the substrate, while pre-applied underfills face filler entrapment at bond pads. In this report, we present a self-patterning underfilling technology that uses selective wetting of underfill on Cu bond pads and Si 3 N 4 passivation via surface energy engineering. This novel process, fully compatible with the conventional underfilling process, eliminates the issue of filler entrapment in typical pre-applied underfilling process, enabling high density and fine pitch IC die bonding.
Fakih, Mohamad G; Skierczynski, Boguslow; Bufalino, Angelo; Groves, Clariecia; Roberts, Phillip; Heavens, Michelle; Hendrich, Ann; Haydar, Ziad
2016-12-01
The standardized infection ratio (SIR) evaluates individual publicly reported health care-associated infections, but it may not assess overall performance. We piloted an infection composite score (ICS) in 82 hospitals of a single health system. The ICS is a combined score for central line-associated bloodstream infections, catheter-associated urinary tract infections, colon and abdominal hysterectomy surgical site infections, and hospital-onset methicillin-resistant Staphylococcus aureus bacteremia and Clostridium difficile infections. Individual facility ICSs were calculated by normalizing each of the 6 SIR events to the system SIR for baseline and performance periods (ICS ib and ICS ip , respectively). A hospital ICS ib reflected its baseline performance compared with system baseline, whereas a ICS ip provided information of its outcome changes compared with system baseline. Both the ICS ib (baseline 2013) and ICS ip (performance 2014) were calculated for 63 hospitals (reporting at least 4 of the 6 event types). The ICS ip improved in 36 of 63 (57.1%) hospitals in 2014 when compared with the ICS ib in 2013. The ICS ib 2013 median was 0.96 (range, 0.13-2.94) versus the 2014 ICS ip median of 0.92 (range, 0-6.55). Variation was more evident in hospitals with ≤100 beds. The system performance score (ICS sp ) in 2014 was 0.95, a 5% improvement compared with 2013. The proposed ICS may help large health systems and state hospital associations better evaluate key infectious outcomes, comparing them with historic and concurrent performance of peers. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
1963-01-15
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. The F-1 Engine test stand was built north of the massive S-IC test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. Looking North, this aerial taken January 15, 1963, gives a closer view of the deep hole for the F-1 test stand site in the forefront. The S-IC test stand with towers prominent is to the right of center, and the Block House is seen left of center.
A Versatile Glass Processor for High-Performance Photonic Platforms
2015-12-08
St . Louis, MO 63130 -4862 ABSTRACT Number of Papers published in peer...Skinner Professor, Electrical and Systems Engineering Department, Washington University, St . Louis, MO 63130 1. Introduction With...al iz ed re so na nc e w av el en gt h sh ift (W G M re so na nc e) a nd no rm al iz ed e la st ic m od ul us c ha ng e (rh eo lo gy ) 0
A PEMFC hybrid electric vehicle real time control system
NASA Astrophysics Data System (ADS)
Sun, Hongqiao
In recent years, environmental friendly technologies and alternative energy solutions have drawn a lot of public attentions due to global energy crisis and pollution issues. Fuel cell (FC), a technology invented almost at the same time as the internal combustion (IC) engine, is now the focus of the automotive industry again. The fuel cell vehicle (FCV) has zero emission and its efficiency is significantly higher than the conventional IC engine power vehicles. Among a variety of FCV technologies, proton exchange membrane (PEM) FC vehicle appears to be far more attractive and mature. The prototype PEMFC vehicle has been developed and demonstrated to the public by nearly all the major automotive manufacturers in recent years. However, to the interest of the public research, publications and documentations on the PEMFC vehicle technology are rarely available due to its proprietary nature, which essentially makes it a secured technology. This dissertation demonstrates a real world application of a PEMFC hybrid electric vehicle. Through presenting the vehicle design concept, developing the real time control system and generating generic operation principles, this dissertation targets at establishing the public knowledge base on this new technology. A complete PEMFC hybrid electric vehicle design, including vehicle components layout, process flow diagram, real time control system architecture, subsystem structures and control algorithms, is presented in order to help understand the whole vehicle system. The design concept is validated through the vehicle demonstration. Generic operating principles are established along with the validation process, which helps populate this emerging technology. Thereafter, further improvements and future research directions are discussed.
NASA Astrophysics Data System (ADS)
Naguib, Hussein; Bol, Igor I.; Lora, J.; Chowdhry, R.
1994-09-01
This paper presents a case study on the implementation of ABC to calculate the cost per wafer and to drive cost reduction efforts for a new IC product line. The cost reduction activities were conducted through the efforts of 11 cross-functional teams which included members of the finance, purchasing, technology development, process engineering, equipment engineering, production control, and facility groups. The activities of these cross functional teams were coordinated by a cost council. It will be shown that these activities have resulted in a 57% reduction in the wafer manufacturing cost of the new product line. Factors contributed to successful implementation of an ABC management system are discussed.
1960-01-01
This image illustrates the basic differences between the three Saturn launch vehicles developed by the Marshall Space Flight Center. The Saturn I, consisted of two stages, the S-I (eight H-1 engines) and the S-IV (six RL-10 engines). The Saturn IB (center) also consisted of two stages, the S-IB (eight H-1 engines) and the S-IVB (one J-2 engine). The Saturn V consisted of three stages, the S-IC (five F-1 engines), the S-II (five J-2 engines), and the S-IVB (one J-2 engine).
Men Working on Mock-Up of S-IC Thrust Structure
NASA Technical Reports Server (NTRS)
1963-01-01
This photograph depicts Marshall Space Flight Center employees, James Reagin, machinist (top); Floyd McGinnis, machinist; and Ernest Davis, experimental test mechanic (foreground), working on a mock up of the S-IC thrust structure. The S-IC stage is the first stage, or booster, of the 364-foot long Saturn V rocket that ultimately took astronauts to the Moon. The S-IC stage, burned over 15 tons of propellant per second during its 2.5 minutes of operation to take the vehicle to a height of about 36 miles and to a speed of about 6,000 miles per hour. The stage was 138 feet long and 33 feet in diameter. Operating at maximum power, all five of the engines produced 7,500,000 pounds of thrust.
Gas Engine-Driven Heat Pump with Desiccant Dehumidification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Bo; Abu-Heiba, Ahmad
About 40% of total U.S. energy consumption was consumed in residential and commercial buildings. Improved air-conditioning technology has by far the greatest potential impact on the electric industry compared to any other technology that uses electricity. This paper describes the development of an innovative natural gas, propane, LNG or bio-gas IC engine-driven heat pump (GHP) with desiccant dehumidification (GHP/DD). This integrated system has higher overall efficiencies than conventional equipment for space cooling, addresses both new and existing commercial buildings, and more effectively controls humidity in humid areas. Waste heat is recovered from the GHP to provide energy for regenerating themore » desiccant wheel and to augment heating capacity and efficiency. By combining the two technologies, an overall source COP of greater that 1.5 (hot, humid case) can be achieved by utilizing waste heat from the engine to reduce the overall energy required to regenerate the desiccant. Moreover, system modeling results show that the sensible heat ratio (SHR- sensible heat ratio) can be lowered to less 60% in a dedicated outdoor air system application with hot, humid cases.« less
1963-08-13
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of August 13, 1963. All four of its tower legs are well underway into the skyline.
PROGRESS IN DESIGN OF THE INSTRUMENTATION AND CONTROL OF THE TOKAMAK COOLING WATER SYSTEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korsah, Kofi; DeVan, Bill; Ashburn, David
This paper discusses progress in the design of the control, interlock and safety systems of the Tokamak Cooling Water System (TCWS) for the ITER fusion reactor. The TCWS instrumentation and control (I&C) is one of approximately 200 separate plant I&C systems (e.g., vacuum system I&C, magnets system I&C) that interface to a common central I&C system through standardized networks. Several aspects of the I&C are similar to the I&C of fission-based power plants. However, some of the unique features of the ITER fusion reactor and the TCWS (e.g., high quasi-static magnetic field, need for baking and drying as well asmore » cooling operations), also demand some unique safety and qualification considerations. The paper compares the design strategy/guidelines of the TCWS I&C and the I&C of conventional nuclear power plants. Issues such as safety classifications, independence between control and safety systems, sensor sharing, redundancy, voting schemes, and qualification methodologies are discussed. It is concluded that independence and separation requirements are similar in both designs. However, the voting schemes for safety systems in nuclear power plants typically use 2oo4 (i.e., 4 divisions of safety I&C, any 2 of which is sufficient to trigger a safety action), while 2oo3 voting logic - within each of 2 independent trains - is used in the TCWS I&C. It is also noted that 2oo3 voting is also acceptable in nuclear power plants if adequate risk assessment and reliability is demonstrated. Finally, while qualification requirements provide similar guidance [e.g., both IEC 60780 (invoked in ITER-space), and IEEE 323 (invoked in fission power plant space) provide similar guidance], an important qualification consideration is the susceptibility of I&C to the magnetic fields of ITER. Also, the radiation environments are different. In the case of magnetic fields the paper discusses some options that are being considered.« less
Boiler Control Systems Oxygen Trim Systems Manual.
1983-02-01
F/ G 5/9 N EhhhhhhhmonsoI smhhhEmhhhhhh smhhhhhhhhhhh Ehh0h0010I-E1E FEmhhhhEmmhhhhhhI LL+4 -.Lm(m~mkl~~d - - ." " - , -, - - ’ - °. ,,_ ". . . b...PAGIES Ik NNITrG A9NC ORS7 Ir- e, 0) 1 SECURITY CLASS. (of K4* MPMf) Office, g &, Washington, DC 20360 Unclassified Naval Facilities Engineering Coand...1NPLJT SoNAI . S141NAL. f* FIR4GIb[CTIQNAL SCkEMIATC DICIAN A’ RLfL FOSITIOWINC- SY<STEM1 (FUUMArIC) PRESSURE PROC.ESS PIIN42 ATI 6 C~rEMASTERO F13UE
Turusbekova, N; Popa, C; Dragos, M; van der Werf, M J; Dinca, I
2016-02-01
In 2012, the tuberculosis (TB) notification rate among Romanian TB facility doctors and nurses was 7.2 times higher than in the general population. This indicates that transmission is ongoing inside TB facilities and that TB infection control measures are insufficient. To help prevent nosocomial TB transmission a project was implemented that aimed at providing nationwide tailor-made technical assistance in TB infection control (TB-IC) in TB treatment facilities, including the development of TB infection control plans. The objective of the present article is to describe the implementation of the project and to discuss successes and challenges. The project was an implementation study using two methods of evaluation: (1) a cross sectional questionnaire study; and (2) collection of information, during the training, on challenges related to infection control and to the project implementation. The project team developed a TB facility infection control (TB-IC) plan template, together with the Romanian experts. The template was discussed and agreed upon with the experts at a meeting and thereafter distributed by email to all TB facilities. Afterwards, a training of trainers (TOT) seminar was organized which included the provision of information about different training methods, as well as information about TB-IC. The TOT was followed by training for key TB-IC providers. Information about use of the TB-IC template was gathered through a self-administered questionnaire sent to all participants of the expert meeting and the training (42 people). Additionally, non-systematized discussions were held on broader challenges in TB-IC implementation during the training. Within the project 42 key TB-IC service providers were trained in TB-IC, including 9 who were trained at a TOT seminar. The trainees were specialists working at the national level, such as country TB coordinators, or at the TB facility level: TB doctors, epidemiologists, laboratory specialists and maintenance engineers. Out of 42 key TB-IC service providers who were trained, only eighteen responded to the questionnaire (no reminders were sent). Out of these, 14 had used the TB-IC plan template after the project team disseminated it to them by email. The remaining four TB-IC service providers indicated that they were planning to use the template to develop or update their facility TB-IC plans. Related to the use of TB-IC plan template, the following broader challenges in TB-IC were identified: a lack of authority of the individuals responsible for TB-IC to implement the TB-IC measures, lack of training among facility epidemiologists on TB, underdeveloped system for reporting TB in healthcare workers, difficulties with triage of the TB suspects, and poor facility infrastructure hampering implementation of TB-IC measures. Implementing TB-IC plans in Romanian health care facilities proved to be challenging, mainly due to the fact that the national infection control plan for TB was not yet adopted at the time of project implementation, and therefore there was neither a regulatory framework to support TB facility-IC planning nor any related budget allocations for the implementation of the facilities' TB-IC plans. Nonetheless, most respondents who answered the questionnaire (18 of 42 responded) indicated that they had started using the TB-IC plan template, which represents a full package of infection control measures that, when implemented effectively and in its entirety, may be expected to reduce nosocomial transmission. The study's limitations are: very low survey response rate, thus there is a likelihood of responder bias. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kisner, R.; Melin, A.; Burress, T.
The objective of this project is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant (NPP) components and systems. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration platform. I&C is intimately part of the basic millisecond-by-millisecond functioning of the system; treating I&C as an integral part of the system design is innovative and will allow significant improvement in capabilities and performance. As systems become more complex and greater performance is required, traditional I&C design techniques become inadequate andmore » more advanced I&C needs to be applied. New I&C techniques enable optimal and reliable performance and tolerance of noise and uncertainties in the system rather than merely monitoring quasistable performance. Traditionally, I&C has been incorporated in NPP components after the design is nearly complete; adequate performance was obtained through over-design. By incorporating I&C at the beginning of the design phase, the control system can provide superior performance and reliability and enable designs that are otherwise impossible. This report describes the progress and status of the project and provides a conceptual design overview for the platform to demonstrate the performance and reliability improvements enabled by advanced embedded I&C.« less
The instrument control software package for the Habitable-Zone Planet Finder spectrometer
NASA Astrophysics Data System (ADS)
Bender, Chad F.; Robertson, Paul; Stefansson, Gudmundur Kari; Monson, Andrew; Anderson, Tyler; Halverson, Samuel; Hearty, Frederick; Levi, Eric; Mahadevan, Suvrath; Nelson, Matthew; Ramsey, Larry; Roy, Arpita; Schwab, Christian; Shetrone, Matthew; Terrien, Ryan
2016-08-01
We describe the Instrument Control Software (ICS) package that we have built for The Habitable-Zone Planet Finder (HPF) spectrometer. The ICS controls and monitors instrument subsystems, facilitates communication with the Hobby-Eberly Telescope facility, and provides user interfaces for observers and telescope operators. The backend is built around the asynchronous network software stack provided by the Python Twisted engine, and is linked to a suite of custom hardware communication protocols. This backend is accessed through Python-based command-line and PyQt graphical frontends. In this paper we describe several of the customized subsystem communication protocols that provide access to and help maintain the hardware systems that comprise HPF, and show how asynchronous communication benefits the numerous hardware components. We also discuss our Detector Control Subsystem, built as a set of custom Python wrappers around a C-library that provides native Linux access to the SIDECAR ASIC and Hawaii-2RG detector system used by HPF. HPF will be one of the first astronomical instruments on sky to utilize this native Linux capability through the SIDECAR Acquisition Module (SAM) electronics. The ICS we have created is very flexible, and we are adapting it for NEID, NASA's Extreme Precision Doppler Spectrometer for the WIYN telescope; we will describe this adaptation, and describe the potential for use in other astronomical instruments.
NASA Astrophysics Data System (ADS)
Rangaswamy, T.; Vidhyashankar, S.; Madhusudan, M.; Bharath Shekar, H. R.
2015-04-01
The current trends of engineering follow the basic rule of innovation in mechanical engineering aspects. For the engineers to be efficient, problem solving aspects need to be viewed in a multidimensional perspective. One such methodology implemented is the fusion of technologies from other disciplines in order to solve the problems. This paper mainly deals with the application of Neural Networks in order to analyze the performance parameters of an XD3P Peugeot engine (used in Ministry of Defence). The basic propaganda of the work is divided into two main working stages. In the former stage, experimentation of an IC engine is carried out in order to obtain the primary data. In the latter stage the primary database formed is used to design and implement a predictive neural network in order to analyze the output parameters variation with respect to each other. A mathematical governing equation for the neural network is obtained. The obtained polynomial equation describes the characteristic behavior of the built neural network system. Finally, a comparative study of the results is carried out.
NASA Technical Reports Server (NTRS)
Willis, E. A.
1982-01-01
An update on general aviation (g/a) and commuter aircraft propulsion research effort is reviewed. The following topics are discussed: on several advanced intermittent combustion engines emphasizing lightweight diesels and rotary stratified charge engines. The current state-of-the-art is evaluated for lightweight, aircraft suitable versions of each engine. This information is used to project the engine characteristics that can be expected on near-term and long-term time horizons. The key enabling technology requirements are identified for each engine on the long-term time horizon.
1962-06-07
This photograph depicts the Rocketdyne static firing of the F-1 engine at the towering 76-meter Test Stand 1-C in Area 1-125 of the Edwards Air Force Base in California. The Saturn V S-IC (first) stage utilized five F-1 engines for its thrust. Each engine provided 1,500,000 pounds, for a combined thrust of 7,500,000 pounds with liquid oxygen and kerosene as its propellants.
Non-Catalytic Reforming with Applications to Portable Power
2013-10-01
and J.J. Beaman, Jr., “Freeform Fabrication of Non-Metallic Objects by Selective Laser Sintering and Infiltration”, Materials Science Forum, 561-565...for syngas production from jet fuel using various methods including catalysts [4, 47-54] and plasmas [55]. Investigations of noncatalytic reforming...Combustion of n-butanol in a spark -ignition IC engine. Fuel. 89(7): p. 1573-1582. 32. Behrens, D.A., I.C. Lee, and C.M. Waits, Catalytic combustion of
Study on a Real-Time BEAM System for Diagnosis Assistance Based on a System on Chips Design
Sung, Wen-Tsai; Chen, Jui-Ho; Chang, Kung-Wei
2013-01-01
As an innovative as well as an interdisciplinary research project, this study performed an analysis of brain signals so as to establish BrainIC as an auxiliary tool for physician diagnosis. Cognition behavior sciences, embedded technology, system on chips (SOC) design and physiological signal processing are integrated in this work. Moreover, a chip is built for real-time electroencephalography (EEG) processing purposes and a Brain Electrical Activity Mapping (BEAM) system, and a knowledge database is constructed to diagnose psychosis and body challenges in learning various behaviors and signals antithesis by a fuzzy inference engine. This work is completed with a medical support system developed for the mentally disabled or the elderly abled. PMID:23681095
Development of Intake Swirl Generators for Turbo Jet Engine Testing
1987-03-01
As a test object a Larxac 04 turbofan engine was chosen which is used as propulsion in the Alpha Jet aircraft . This twospool engine features a two...a__ OPI: !’fIC-TID N .18.1 DEVELOPMENT OF NAR 8WZRL GENERATORS FOR TURBO JET ENGINE TU TING by H.P. Gensmlor*, W. Meyer**, L. Fottner*** Dipl.-Ing...at the Universitit der Bundeswehr MUnchen. The test facility is designed for turbo jet engines up to an maximum thrust of 30kN and a maximum mass
Stable Electrical Operation of 6H-SiC JFETs and ICs for Thousands of Hours at 500 C
NASA Technical Reports Server (NTRS)
Neudeck, Philip G.; Spry, David J.; Chen, Liang-Yu; Beheim, Glenn M.; Okojie, Robert S.; Chang, Carl W.; Meredith, Roger D.; Ferrier, Terry L.; Evans, Laura J.; Krasowski, Michael J.;
2008-01-01
The fabrication and testing of the first semiconductor transistors and small-scale integrated circuits (ICs) to achieve up to 3000 h of stable electrical operation at 500 C in air ambient is reported. These devices are based on an epitaxial 6H-SiC junction field-effect transistor process that successfully integrated high temperature ohmic contacts, dielectric passivation, and ceramic packaging. Important device and circuit parameters exhibited less than 10% of change over the course of the 500 C operational testing. These results establish a new technology foundation for realizing durable 500 C ICs for combustion-engine sensing and control, deep-well drilling, and other harsh-environment applications.
Aleiferis, Pavlos; Charalambides, Alexandros; Hardalupas, Yannis; Soulopoulos, Nikolaos; Taylor, A M K P; Urata, Yunichi
2015-05-10
Schlieren [Schlieren and Shadowgraphy Techniques (McGraw-Hill, 2001); Optics of Flames (Butterworths, 1963)] is a non-intrusive technique that can be used to detect density variations in a medium, and thus, under constant pressure and mixture concentration conditions, measure whole-field temperature distributions. The objective of the current work was to design a schlieren system to measure line-of-sight (LOS)-averaged temperature distribution with the final aim to determine the temperature distribution inside the cylinder of internal combustion (IC) engines. In a preliminary step, we assess theoretically the errors arising from the data reduction used to determine temperature from a schlieren measurement and find that the total error, random and systematic, is less than 3% for typical conditions encountered in the present experiments. A Z-type, curved-mirror schlieren system was used to measure the temperature distribution from a hot air jet in an open air environment in order to evaluate the method. Using the Abel transform, the radial distribution of the temperature was reconstructed from the LOS measurements. There was good agreement in the peak temperature between the reconstructed schlieren and thermocouple measurements. Experiments were then conducted in a four-stroke, single-cylinder, optical spark ignition engine with a four-valve, pentroof-type cylinder head to measure the temperature distribution of the reaction zone of an iso-octane-air mixture. The engine optical windows were designed to produce parallel rays and allow accurate application of the technique. The feasibility of the method to measure temperature distributions in IC engines was evaluated with simulations of the deflection angle combined with equilibrium chemistry calculations that estimated the temperature of the reaction zone at the position of maximum ray deflection as recorded in a schlieren image. Further simulations showed that the effects of exhaust gas recirculation and air-to-fuel ratio on the schlieren images were minimal under engine conditions compared to the temperature effect. At 20 crank angle degrees before top dead center (i.e., 20 crank angle degrees after ignition timing), the measured temperature of the flame front was in agreement with the simulations (730-1320 K depending on the shape of the flame front). Furthermore, the schlieren images identified the presence of hot gases ahead of the reaction zone due to diffusion and showed that there were no hot spots in the unburned mixture.
Present, future of automotive hybrid IC applications discussed
NASA Astrophysics Data System (ADS)
Matsuda, Nobuyoshi; Fukuoka, Atuhisa
1987-09-01
Hybrid ICs are presently utilized in various fields such as commercial televisions, VTRs, and audio devices, industrial usage of communication equipment, computers, terminals, and automobiles. Its applications and environments are various and diverse. The functions required for hybrid ICs vary from simple high density mounting for a system to the realization of high mechanisms with the application of function timing. The functions are properly used depending upon the system with its hybrid ICs and its circuit composition. Considering structure and reliability requirements for automotive hybrid ICs, an application example for hybrid ICs which use the package (COMPACT), will be discussed.
Natural gas applications for hybrid vehicles. Final report, October 1992-July 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bentley, J.M.
1993-08-01
Hybrid vehicle technology holds the potential for improved efficiency and emissions compared with internal combustion (IC) engines and improved range and refueling convenience over electric vehicles. This study evaluated the potential for using natural gas as a hybrid vehicle fuel. Potential regulatory and market drivers were evaluated for hybrids generally and natural gas hybrids in specific. Heat engine options and other configuration issues were investigated to determine efficiency, emissions or other benefits of light- and heavy-duty hybrids. Several hybrid vehicle configurations were evaluated to determine the specific packaging attributes of natural gas in a hybrid configuration. Generally, conventional IC enginesmore » appear adequate for most emissions-sensitive hybrid applications with no great advantage being gained from using turbines or other more advanced heat engines. The largest technology barrier to a near-term hybrid is the weight of available or near-term batteries. Smaller, light-duty hybrid vehicles will be more sensitive to this weight handicap than larger vehicles such as the urban transit bus.« less
Methanol decomposition bottoming cycle for IC engines
NASA Technical Reports Server (NTRS)
Purohit, G.; Houseman, J.
1979-01-01
This paper presents the concept of methanol decomposition using engine exhaust heat, and examines its potential for use in the operation of passenger cars, diesel trucks, and diesel-electric locomotives. Energy economy improvements of 10-20% are calculated over the representative driving cycles without a net loss in power. Some reductions in exhaust emissions are also projected.
Regional interoperability: making systems connect in complex disasters.
Briggs, Susan Miller
2009-08-01
Effective use of the Incident Command System (ICS) is the key to regional interoperability. Many different organizations with different command structures and missions respond to a disaster. The ICS allows different kinds of agencies (fire, police, and medical) to work together effectively in response to a disaster. Functional requirements, not titles, determine the organizational hierarchy of the ICS structure. The ICS is a modular/adaptable system for all disasters regardless of etiology and for all organizations regardless of size.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-20
... NUCLEAR REGULATORY COMMISSION Advisory Committee on Reactor Safeguards (ACRS); Meeting of the ACRS Subcommittee on Digital I&C Systems The ACRS Subcommittee on Digital Instrumentation and Controls (I&C) Systems...: Wednesday, September 8, 2010--8:30 a.m. until 12 p.m. The Subcommittee will review Digital I&C Interim Staff...
6H-SiC Transistor Integrated Circuits Demonstrating Prolonged Operation at 500 C
NASA Technical Reports Server (NTRS)
Neudeck, Philip G.; Spry, David J.; Chen, Liang-Yu; Chang, Carl W.; Beheim, Glenn M.; Okojie, Robert S.; Evans, Laura J.; Meredith, Roger; Ferrier, Terry; Krasowski, Michael J.;
2008-01-01
The NASA Glenn Research Center is developing very high temperature semiconductor integrated circuits (ICs) for use in the hot sections of aircraft engines and for Venus exploration where ambient temperatures are well above the approximately 300 degrees Centigrade effective limit of silicon-on-insulator IC technology. In order for beneficial technology insertion to occur, such transistor ICs must be capable of prolonged operation in such harsh environments. This paper reports on the fabrication and long-term 500 degrees Centigrade operation of 6H-SiC integrated circuits based on epitaxial 6H-SiC junction field effect transistors (JFETs). Simple analog amplifier and digital logic gate ICs have now demonstrated thousands of hours of continuous 500 degrees Centigrade operation in oxidizing air atmosphere with minimal changes in relevant electrical parameters. Electrical characterization and modeling of transistors and circuits at temperatures from 24 degrees Centigrade to 500 degrees Centigrade is also described. Desired analog and digital IC functionality spanning this temperature range was demonstrated without changing the input signals or power supply voltages.
SPROC: A multiple-processor DSP IC
NASA Technical Reports Server (NTRS)
Davis, R.
1991-01-01
A large, single-chip, multiple-processor, digital signal processing (DSP) integrated circuit (IC) fabricated in HP-Cmos34 is presented. The innovative architecture is best suited for analog and real-time systems characterized by both parallel signal data flows and concurrent logic processing. The IC is supported by a powerful development system that transforms graphical signal flow graphs into production-ready systems in minutes. Automatic compiler partitioning of tasks among four on-chip processors gives the IC the signal processing power of several conventional DSP chips.
1963-03-24
This photograph depicts Marshall Space Flight Center employees, James Reagin, machinist (top); Floyd McGinnis, machinist; and Ernest Davis, experimental test mechanic (foreground), working on a mock up of the S-IC thrust structure. The S-IC stage is the first stage, or booster, of the 364-foot long Saturn V rocket that ultimately took astronauts to the Moon. The S-IC stage, burned over 15 tons of propellant per second during its 2.5 minutes of operation to take the vehicle to a height of about 36 miles and to a speed of about 6,000 miles per hour. The stage was 138 feet long and 33 feet in diameter. Operating at maximum power, all five of the engines produced 7,500,000 pounds of thrust.
Chen, Qian; Abercrombie, Robert K; Sheldon, Frederick T.
2015-09-23
Industrial Control Systems (ICS) are commonly used in industries such as oil and natural gas, transportation, electric, water and wastewater, chemical, pharmaceutical, pulp and paper, food and beverage, as well as discrete manufacturing (e.g., automotive, aerospace, and durable goods.) SCADA systems are generally used to control dispersed assets using centralized data acquisition and supervisory control.Originally, ICS implementations were susceptible primarily to local threats because most of their components were located in physically secure areas (i.e., ICS components were not connected to IT networks or systems). The trend toward integrating ICS systems with IT networks (e.g., efficiency and the Internet ofmore » Things) provides significantly less isolation for ICS from the outside world thus creating greater risk due to external threats. Albeit, the availability of ICS/SCADA systems is critical to assuring safety, security and profitability. Such systems form the backbone of our national cyber-physical infrastructure.Herein, we extend the concept of mean failure cost (MFC) to address quantifying availability to harmonize well with ICS security risk assessment. This new measure is based on the classic formulation of Availability combined with Mean Failure Cost (MFC). Finally, the metric offers a computational basis to estimate the availability of a system in terms of the loss that each stakeholder stands to sustain as a result of security violations or breakdowns (e.g., deliberate malicious failures).« less
1968-01-01
A complete F-1 engine assembly is shown in this photograph. Designed and developed by Rocketdye under the direction of the Marshall Space Flight Center, the engine measured 19-feet tall by 12.5 feet at the nozzle exit, and each engine produced a 1,500,000-pound thrust using liquid oxygen and kerosene as the propellant. A cluster of five F-1 engines was mounted on the Saturn V S-IC (first) stage and burned 15 tons of liquid oxygen and kerosene each second to produce 7,500,000 pounds of thrust.
Controlled delivery of icariin on small intestine submucosa for bone tissue engineering.
Li, Mei; Gu, Qiaoqiao; Chen, Mengjie; Zhang, Chi; Chen, Songdi; Zhao, Jiyuan
2017-02-01
Small intestine submucosa (SIS) has been reported as an excellent biomaterial for tissue engineering because of its naturally occurring collagenous extracellular matrix property with growth factors. However, SIS from submucosal layer of intestine provides different microenvironment from bone tissue, which limits its application to bone regeneration. The object of this study was to improve osteoinductivity of SIS by controlled local delivery of icariin (Ic), a potent osteogenic compound. Sustained release of icariin from SIS scaffold was achieved for >30days and the loading of icariin on SIS scaffold was uniform as scanned by SEM. In vitro experiments revealed that expression of osteogenic differentiation markers (Alp, Bsp and Ocn) was increased after treatment of Ic-SIS scaffold, without significant cytotoxicity. In an in vivo mouse calvarial defect model, bone regeneration was enhanced by SIS implantation at 8weeks, compared to control defect. New bone formation was further improved by implantation with Ic-SIS (low and high) at both 4 and 8weeks. The results of this study suggest that SIS scaffold has the potential as an icariin delivery carrier for enhancement of bone regeneration. Copyright © 2016 Elsevier B.V. All rights reserved.
Mod 1 ICS TI Report: ICS Conversion of a 140% HPGe Detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bounds, John Alan
This report evaluates the Mod 1 ICS, an electrically cooled 140% HPGe detector. It is a custom version of the ORTEC Integrated Cooling System (ICS) modified to make it more practical for us to use in the field. Performance and operating characteristics of the Mod 1 ICS are documented, noting both pros and cons. The Mod 1 ICS is deemed a success. Recommendations for a Mod 2 ICS, a true field prototype, are provided.
1963-01-01
Marshall Space Flight Center successfully conducted hydrostatic testing on the Saturn V S-IC (first) stage fuel tank. The first stage was powered by five F-1 engines, that used liquid oxygen and kerosene as its propellant.
Multipurpose Educational Modules to Teach Hydraulic Hybrid Vehicle Technologies
DOT National Transportation Integrated Search
2007-09-01
The goal of the overall project is to develop a software simulation for a hydraulic hybrid vehicle. The simulation will enable students to compare various hybrid configurations with conventional IC engine performance.
Detecting Cyber Attacks On Nuclear Power Plants
NASA Astrophysics Data System (ADS)
Rrushi, Julian; Campbell, Roy
This paper proposes an unconventional anomaly detection approach that provides digital instrumentation and control (I&C) systems in a nuclear power plant (NPP) with the capability to probabilistically discern between legitimate protocol frames and attack frames. The stochastic activity network (SAN) formalism is used to model the fusion of protocol activity in each digital I&C system and the operation of physical components of an NPP. SAN models are employed to analyze links between protocol frames as streams of bytes, their semantics in terms of NPP operations, control data as stored in the memory of I&C systems, the operations of I&C systems on NPP components, and NPP processes. Reward rates and impulse rewards are defined in the SAN models based on the activity-marking reward structure to estimate NPP operation profiles. These profiles are then used to probabilistically estimate the legitimacy of the semantics and payloads of protocol frames received by I&C systems.
Self-Adaptive System based on Field Programmable Gate Array for Extreme Temperature Electronics
NASA Technical Reports Server (NTRS)
Keymeulen, Didier; Zebulum, Ricardo; Rajeshuni, Ramesham; Stoica, Adrian; Katkoori, Srinivas; Graves, Sharon; Novak, Frank; Antill, Charles
2006-01-01
In this work, we report the implementation of a self-adaptive system using a field programmable gate array (FPGA) and data converters. The self-adaptive system can autonomously recover the lost functionality of a reconfigurable analog array (RAA) integrated circuit (IC) [3]. Both the RAA IC and the self-adaptive system are operating in extreme temperatures (from 120 C down to -180 C). The RAA IC consists of reconfigurable analog blocks interconnected by several switches and programmable by bias voltages. It implements filters/amplifiers with bandwidth up to 20 MHz. The self-adaptive system controls the RAA IC and is realized on Commercial-Off-The-Shelf (COTS) parts. It implements a basic compensation algorithm that corrects a RAA IC in less than a few milliseconds. Experimental results for the cold temperature environment (down to -180 C) demonstrate the feasibility of this approach.
PREFACE: The Second Conference on Microelectronics, Microsystems and Nanotechnology
NASA Astrophysics Data System (ADS)
Nassiopoulou, Androula G.; Papanikolaou, Nikos; Tsamis, Christos
2005-01-01
The Second Conference on Microelectronics, Microsystems and Nanotechnology took place at the National Centre for Scientific Research `Demokritos', in Athens, Greece, between 14 and 17 November 2004. The conference was organized by the Institute of Microelectronics (IMEL) with the aim to bring together scientists and engineers working in the above exciting fields in an interactive forum. The conference included 45 oral presentations with 9 invited papers and was attended by 146 participants from 16 countries. The topics covered were nanotechnologies, quantum devices, sensors, micro- and nano-systems, semiconductor devices, C-MOS fabrication and characterization techniques, new materials, and IC design. Quantum devices and nanostructured materials attracted considerable attention. Both theoretical and experimental studies of metallic and semiconducting quantum systems were presented, with emphasis on their applications in electronics, optoelectronics, and nanocrystal memory devices. Another exciting topic was the recent developments in biocompatible lithographic processes for applications in biosensors. In particular novel processes for bio-friendly lithography, together with innovations in Si sensors for applications in medicine and food industry were presented. Recent developments and perspectives in CMOS technology towards the ultimate limit were also discussed. The conference covered issues and concepts of IC design with two invited talks on RF design and cryptography.The conference included presentations from several companies active in the field of microelectronics and systems in Greece.
System and method for floating-substrate passive voltage contrast
Jenkins, Mark W [Albuquerque, NM; Cole, Jr., Edward I.; Tangyunyong, Paiboon [Albuquerque, NM; Soden, Jerry M [Placitas, NM; Walraven, Jeremy A [Albuquerque, NM; Pimentel, Alejandro A [Albuquerque, NM
2009-04-28
A passive voltage contrast (PVC) system and method are disclosed for analyzing ICs to locate defects and failure mechanisms. During analysis a device side of a semiconductor die containing the IC is maintained in an electrically-floating condition without any ground electrical connection while a charged particle beam is scanned over the device side. Secondary particle emission from the device side of the IC is detected to form an image of device features, including electrical vias connected to transistor gates or to other structures in the IC. A difference in image contrast allows the defects or failure mechanisms be pinpointed. Varying the scan rate can, in some instances, produce an image reversal to facilitate precisely locating the defects or failure mechanisms in the IC. The system and method are useful for failure analysis of ICs formed on substrates (e.g. bulk semiconductor substrates and SOI substrates) and other types of structures.
1986-01-01
switching the PMIGG into the high pressure/high flow mode was changed from a fuel system pressure sensor to a product gas flow sensor , in-line with the...cycle madu.w 0 IC Aw a De *Vatwue aid coitfh 3 M0aMSadO~t310 h* Pra dwatz and pkswacip 170130 9 P"mw *a as PDMW 170 11e1 otl71261 TOWs 7V 9^ W~~W1004...and glycol from de -icing. The following is a list of potential substances: Substance Engine Lube Oil Hydraulic Oil1 Cleaning Fluids Glycol The
2006-10-26
tte r M r. D ea n C ar ic o TR AC K 1 Sy st em s En gi ne er in g Ef fe ct iv en es s M r. Al B ro...FS S) T oo ls - PG M M Ca se S tu dy M r. D ou gl as S to rs ve d Pa tte rn L ib ra ry fo r Us e in W ea po ns S ys te m E ng in ee...Sensors Sensors Sensors Sensors Air, Land or Sea Undersea or from the Sea (C3) (C2)( ) Sensors Sensors
VR/LE engine with a variable R/L during a single cycle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rychter, T.J.; Teodorczyk, A.
1985-01-01
A new concept of an engine, called a Variable R/L Engine (VR/LE) is presented. The main feature of the engine is the continuous change of the crank-radius to connecting-rod-length ratio (R/L) during the single engine cycle. The variations of the phase angle result in changes of all the engine stroke lengths and also-they are causing the changes of the thermodynamic cycle of the engine. Therefore the phase angle variations make it possible to regulate continuously the compression ratio and the displacement volume of the engine within the range which depends on the engine mechanism geometry. The presented concept can bemore » applied to all the types of the IC piston engines, independently of their size and operation principle.« less
Roos, Leslie E.; Knight, Erik L.; Beauchamp, Kathryn G.; Berkman, Elliot T.; Faraday, Kelsie; Hyslop, Katie; Fisher, Philip A.
2017-01-01
Identifying environmental influences on inhibitory control (IC) may help promote positive behavioral and social adjustment. Although chronic stress is known to predict lower IC, the immediate effects of acute stress are unknown. The parasympathetic nervous system (PNS) may be a mechanism of the stress-IC link, given its psychophysiological regulatory role and connections to prefrontal brain regions critical to IC. We used a focused assessment of IC (the stop-signal task) to test whether an acute social stressor (the Trier Social Stress Test) affected participants’ pre- to post-IC performance (n = 58), compared to a control manipulation (n = 31). High frequency heart-rate variability was used as an index of PNS activity in response to the manipulation. Results indicated that stress impaired IC performance, blocking the practice effects observed in control participants. We also investigated the associations between PNS activity and IC; higher resting PNS activity predicted better pre-manipulation IC, and greater PNS stressor reactivity protected against the negative effects of stress on IC. Together, these results are the first to document the immediate effects of acute stress on IC and a phenotypic marker (PNS reactivity to stressors) of susceptibility to stress-induced IC impairment. This study suggests a new way to identify situations in which individuals are likely to exhibit IC vulnerability and related consequences such as impulsivity and risk taking behavior. Targeting PNS regulation may represent a novel target for IC-focused interventions. PMID:28268165
Processing and Characterization of Thousand-Hour 500 C Durable 4H-SiC JFET Integrated Circuits
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Chen, Liangyu; Lukco, Dorothy; Chang, Carl W.; Beheim, Glenn M.; Krasowski, Michael J.; Prokop, Norman F.
2016-01-01
This work reports fabrication and testing of integrated circuits (ICs) with two levels of interconnect that consistently achieve greater than 1000 hours of stable electrical operation at 500 C in air ambient. These ICs are based on 4H-SiC junction field effect transistor (JFET) technology that integrates hafnium ohmic contacts with TaSi2 interconnects and SiO2 and Si3N4 dielectric layers over 1-m scale vertical topology. Following initial burn-in, important circuit parameters remain stable for more than 1000 hours of 500 C operational testing. These results advance the technology foundation for realizing long-term durable 500 C ICs with increased functional capability for sensing and control combustion engine, planetary, deep-well drilling, and other harsh-environment applications.
Processing and Characterization of Thousand-Hour 500 C Durable 4H-SiC JFET Integrated Circuits
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Chen, Liang-Yu; Lukco, Dorothy; Chang, Carl W.; Beheim, Glenn M.; Krasowski, Michael J.; Prokop, Norman F.
2016-01-01
This work reports fabrication and testing of integrated circuits (ICs) with two levels of interconnect that consistently achieve greater than 1000 hours of stable electrical operation at 500 C in air ambient. These ICs are based on 4H-SiC junction field effect transistor (JFET) technology that integrates hafnium ohmic contacts with TaSi2 interconnects and SiO2 and Si3N4 dielectric layers over approximately 1-micrometer scale vertical topology. Following initial burn-in, important circuit parameters remain stable for more than 1000 hours of 500 C operational testing. These results advance the technology foundation for realizing long-term durable 500 C ICs with increased functional capability for sensing and control combustion engine, planetary, deep-well drilling, and other harsh-environment applications.
Institutional computing (IC) information session
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koch, Kenneth R; Lally, Bryan R
2011-01-19
The LANL Institutional Computing Program (IC) will host an information session about the current state of unclassified Institutional Computing at Los Alamos, exciting plans for the future, and the current call for proposals for science and engineering projects requiring computing. Program representatives will give short presentations and field questions about the call for proposals and future planned machines, and discuss technical support available to existing and future projects. Los Alamos has started making a serious institutional investment in open computing available to our science projects, and that investment is expected to increase even more.
Using Honeynets and the Diamond Model for ICS Threat Analysis
2016-05-11
TR-006 | SOFTWARE ENGINEERING INSTITUTE | CARNEGIE MELLON UNIVERSITY Distribution Statement A: Approved for Public Release; Distribution is...Unlimited Copyright 2016 Carnegie Mellon University This material is based upon work funded and supported by Department of Homeland Security under Contract...No. FA8721-05-C-0003 with Carnegie Mellon University for the operation of the Software Engineering Institute, a federally funded research and
Productivity improvement through industrial engineering in the semiconductor industry
NASA Astrophysics Data System (ADS)
Meyersdorf, Doron
1996-09-01
Industrial Engineering is fairly new to the semiconductor industry, though the awareness to its importance has increased in recent years. The US semiconductor industry in particular has come to the realization that in order to remain competitive in the global market it must take the lead not only in product development but also in manufacturing. Industrial engineering techniques offer one ofthe most effective strategies for achieving manufacturing excellence. Industrial engineers play an important role in the success of the manufacturing facility. This paper defines the Industrial engineers role in the IC facility, set the visions of excellence in semiconductor manufacturing and highlights 10 roadblocks on the journey towards manufacturing excellence.
F-1 Engine for Saturn V Undergoing a Static Test
NASA Technical Reports Server (NTRS)
1964-01-01
The flame and exhaust from the test firing of an F-1 engine blast out from the Saturn S-IB Static Test Stand in the east test area of the Marshall Space Flight Center. A Cluster of five F-1 engines, located in the S-IC (first) stage of the Saturn V vehicle, provided over 7,500,000 pounds of thrust to launch the giant rocket. The towering 363-foot Saturn V was a multistage, multiengine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. Cunningham and J. Shank
2004-11-01
To continue meeting safety and reliability requirements while controlling costs, operators of nuclear power plants must be able to replace and upgrade equipment in a cost-effective manner. One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I&C) systems in recent years is electromagnetic compatibility (EMC). The EMC issue usually involves testing to show that critical equipment will not be adversely affected by electromagnetic interference (EMI) in the plant environment. This guide will help nuclear plant engineers address EMC issues and qualification testing in a consistent, comprehensive manner.
Migration of Older to New Digital Control Systems in Nuclear Power Plant Main Control Rooms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovesdi, Casey Robert; Joe, Jeffrey Clark
The United States (U.S.) Department of Energy (DOE) Office of Nuclear Energy (NE) has the primary mission to advance nuclear power by resolving socio-technical issues through research and development (R&D). One DOE-NE activity supporting this mission is the Light Water Reactor Sustainability (LWRS) program. LWRS has the overall objective to sustain the operation of existing commercial nuclear power plants (NPPs) through conducting R&D across multiple “pathways,” or R&D focus areas. The Advanced Instrumentation, Information, and Control (II&C) Systems Technologies pathway conducts targeted R&D to address aging and reliability concerns with the legacy instrumentation and control (I&C) and related information systemsmore » in operating U.S. NPPs. This work involves (1) ensuring that legacy analog II&C systems are not life-limiting issues for the LWR fleet, and (2) implementing digital II&C technology in a manner that enables broad innovation and business improvement in the NPP operating model. Under the LWRS Advanced II&C pathway, Human Factors experts at Idaho National Laboratory (INL) have been conducting R&D in support of NPP main control room (MCR) modernization activities. Work in prior years has focused on migrating analog I&C systems to new digital I&C systems (). In fiscal year 2016 (FY16), one new focus area for this research is migrating older digital I&C systems to new and advanced digital I&C systems. This report summarizes a plan for conducting a digital-to-digital migration of a legacy digital I&C system to a new digital I&C system in support of control room modernization activities.« less
Magnetar-powered Supernovae in Two Dimensions. II. Broad-line Supernovae Ic
NASA Astrophysics Data System (ADS)
Chen, Ke-Jung; Moriya, Takashi J.; Woosley, Stan; Sukhbold, Tuguldur; Whalen, Daniel J.; Suwa, Yudai; Bromm, Volker
2017-04-01
Nascent neutron stars (NSs) with millisecond periods and magnetic fields in excess of 1016 Gauss can drive highly energetic and asymmetric explosions known as magnetar-powered supernovae. These exotic explosions are one theoretical interpretation for supernovae Ic-BL, which are sometimes associated with long gamma-ray bursts. Twisted magnetic field lines extract the rotational energy of the NS and release it as a disk wind or a jet with energies greater than 1052 erg over ˜20 s. What fraction of the energy of the central engine go into the wind and the jet remain unclear. We have performed two-dimensional hydrodynamical simulations of magnetar-powered supernovae (SNe) driven by disk winds and jets with the CASTRO code to investigate the effect of the central engine on nucleosynthetic yields, mixing, and light curves. We find that these explosions synthesize less than 0.05 {M}⊙ of {}56{Ni} and that this mass is not very sensitive to central engine type. The morphology of the explosion can provide a powerful diagnostic of the properties of the central engine. In the absence of a circumstellar medium, these events are not very luminous, with peak bolometric magnitudes of {M}b˜ -16.5 due to low {}56{Ni} production.
Carbon Monoxide Exposure in Youth Ice Hockey.
Macnow, Theodore; Mannix, Rebekah; Meehan, William P
2017-11-01
To examine the effect of ice resurfacer type on carboxyhemoglobin levels in youth hockey players. We hypothesized that players in arenas with electric resurfacers would have normal, stable carboxyhemoglobin levels during games, whereas those in arenas with internal combustion engine (IC) resurfacers would have an increase in carboxyhemoglobin levels. Prospective cohort study. Enclosed ice arenas in the northeastern United States. Convenience sample of players aged 8 to 18 years old in 16 games at different arenas. Eight arenas (37 players) used an IC ice resurfacer and 8 arenas (36 players) an electric resurfacer. Carboxyhemoglobin levels (SpCO) were measured using a pulse CO-oximeter before and after the game. Arena air was tested for carbon monoxide (CO) using a metered gas detector. Players completed symptom questionnaires. The change in SpCO from pregame to postgame was compared between players at arenas with electric versus IC resurfacers. Carbon monoxide was present at 6 of 8 arenas using IC resurfacers, levels ranged from 4 to 42 parts per million. Carbon monoxide was not found at arenas with electric resurfacers. Players at arenas with IC resurfacers had higher median pregame SpCO levels compared with those at electric arenas (4.3% vs 1%, P < 0.01). Players in the IC group also had a significant increase in their SpCO level during a hockey game compared with those in the electric group (2.8% vs 1%, P = 0.01). There were no significant differences in symptom scores. Players at arenas operating IC resurfacers had significantly higher SpCO levels. Youth hockey players in arenas with IC resurfacers have an increase in carboxyhemoglobin during games and have elevated baseline carboxyhemoglobin levels compared with players at arenas with electric resurfacers. Electric resurfacers decrease the risk of CO exposure.
Durability Testing of Tank Track Rubber Compounds under Cyclic Loading
1987-10-15
depiction of time-to-failure vs applied ( engineering ) stress for 15TP-14AX rubber compounds in creep experiments at 23"C. (After McKenna (1...behavior of the 15TP-14AX rubber was carried out at 23, 75, 125 and 175 OC. The logarithm of the time to failure vs. the applied ( engineering ) stress is...4 3I. I I 5 10 15 a/MPa Figure 3-7 Semilogarith±ic depiction of time-to--failure vs applied ( engineering ) stress for 15TP-14AX rubber compounds in
1964-03-01
The flame and exhaust from the test firing of an F-1 engine blast out from the Saturn S-IB Static Test Stand in the east test area of the Marshall Space Flight Center. A Cluster of five F-1 engines, located in the S-IC (first) stage of the Saturn V vehicle, provided over 7,500,000 pounds of thrust to launch the giant rocket. The towering 363-foot Saturn V was a multistage, multiengine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.
2012-04-01
ER D C/ G SL T R -1 2 -1 5 Pavement -Transportation Computer Assisted Structural Engineering (PCASE) Implementation of the Modified...Berggren (ModBerg) Equation for Computing the Frost Penetration Depth within Pavement Structures G eo te ch n ic al a n d S tr u ct u re s La b or at...April 2012 Pavement -Transportation Computer Assisted Structural Engineering (PCASE) Implementation of the Modified Berggren (ModBerg) Equation for
NASA Astrophysics Data System (ADS)
Jarboe, N.; Minnett, R.; Koppers, A.; Constable, C.; Tauxe, L.; Jonestrask, L.
2017-12-01
The Magnetics Information Consortium (MagIC) supports an online database for the paleo, geo, and rock magnetic communities ( https://earthref.org/MagIC ). Researchers can upload data into the archive and download data as selected with a sophisticated search system. MagIC has completed the transition from an Oracle backed, Perl based, server oriented website to an ElasticSearch backed, Meteor based thick client website technology stack. Using JavaScript on both the sever and the client enables increased code reuse and allows easy offloading many computational operations to the client for faster response. On-the-fly data validation, column header suggestion, and spreadsheet online editing are some new features available with the new system. The 3.0 data model, method codes, and vocabulary lists can be browsed via the MagIC website and more easily updated. Source code for MagIC is publicly available on GitHub ( https://github.com/earthref/MagIC ). The MagIC file format is natively compatible with the PmagPy ( https://github.com/PmagPy/PmagPy) paleomagnetic analysis software. MagIC files can now be downloaded from the database and viewed and interpreted in the PmagPy GUI based tool, pmag_gui. Changes or interpretations of the data can then be saved by pmag_gui in the MagIC 3.0 data format and easily uploaded to the MagIC database. The rate of new contributions to the database has been increasing with many labs contributing measurement level data for the first time in the last year. Over a dozen file format conversion scripts are available for translating non-MagIC measurement data files into the MagIC format for easy uploading. We will continue to work with more labs until the whole community has a manageable workflow for contributing their measurement level data. MagIC will continue to provide a global repository for archiving and retrieving paleomagnetic and rock magnetic data and, with the new system in place, be able to more quickly respond to the community's requests for changes and improvements.
ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.
Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu
2015-02-01
IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.
Productivity improvement through industrial engineering in the semiconductor industry
NASA Astrophysics Data System (ADS)
Meyersdorf, Doron
1996-09-01
Industrial engineering is fairly new to the semiconductor industry, though the awareness to its importance has increased in recent years. The U.S. semiconductor industry in particular has come to the realization that in order to remain competitive in the global market it must take the lead not only in product development but also in manufacturing. Industrial engineering techniques offer one of the most effective strategies for achieving manufacturing excellence. Industrial engineers play an important role in the success of the manufacturing facility. This paper defines the industrial engineers role in the IC facility, sets the visions of excellence in semiconductor manufacturing and highlights 10 roadblocks on the journey towards manufacturing excellence.
1963-12-05
The test laboratory of the Marshall Space Flight Center (MSFC) tested the F-1 engine, the most powerful rocket engine ever fired at MSFC. The engine was tested on the newly modified Saturn IB Static Test Stand which had been used for three years to test the Saturn I eight-engine booster, S-I (first) stage. In 1961 the test stand was modified to permit static firing of the S-I/S-IB stage and the name of the stand was then changed to the S-IB Static Test Stand. Producing a combined thrust of 7,500,000 pounds, five F-1 engines powered the S-IC (first) stage of the Saturn V vehicle for the marned lunar mission.
1963-12-01
The test laboratory of the Marshall Space Flight Center (MSFC) tested the F-1 engine, the most powerful rocket engine ever fired at MSFC. The engine was tested on the newly modified Saturn IB static test stand that had been used for three years to test the Saturn I eight-engine booster, S-I (first) stage. In 1961, the test stand was modified to permit static firing of the S-I/S-IB stage and the name of the stand was then changed to the S-IB Static Test Stand. Producing a combined thrust of 7,500,000 pounds, five F-1 engines powered the S-IC (first) stage of the Saturn V vehicle for the marned lunar mission.
International Space Agency CIO Forum Industrial Control System (ICS) and Cyber
NASA Technical Reports Server (NTRS)
Powell, Robert
2017-01-01
This briefing covers Industrial Control System (ICS) best practices for enhancing cyber protection. The briefing provides a very high-level overview of best practices currently being pursued by NASA as well as by other US government agencies such as NIST and DHS ICS-CERT. All information presented in this slide deck is publicly available and no sensitive information is provided in these slides. These slides will be used to generate discussion around best practices within the international community in the area of ICS cyber protections.
JANNAF Lessons Learned Panel Discussion
NASA Technical Reports Server (NTRS)
Richards, Steve
2010-01-01
The difference between the AS-510 observed and predicted separation distance is attributed to a greater F-1 engine "tail off" impulse than that used in the separation distance prediction. . The F-1 thrust decay was normal and not appreciably different from previous (AS-505 through 509) flights. . Analysis indicates that with an S-IC stage having only four retro motors, failure of one retro motor to ignite would result in marginal separation distances and, in the 3-sigma case, re-contact of the two stages. . S-IC-11 and subsequent flight stages were equipped with eight retro motors rather than the planned four.
A Simple Data Logging System for Ballistic Applications
2006-07-01
6. AUTHOR(S) Thomas Kottke 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Army Research Laboratory ATTN...AMSRD-ARL-WM-TE Aberdeen Proving Ground, MD 21005-5066 8. PERFORMING ORGANIZATION REPORT NUMBER ARL-TR-3853 10. SPONSOR/MONITOR’S ACRONYM(S...IC2 PIC18F458-I/L-ND $185.50/25 IC SOCKET PLCC 44POS SMT for IC2 ED80010-ND $15.05/10 IC SRAM 512KX8 LP WIDE 32- SOIC IC1 and IC4 428-1075-ND $118.00
The Chiasmus of Design: Paradoxical Outcomes in the e-Government Reform of UK Children's Services
NASA Astrophysics Data System (ADS)
Wastell, David; White, Sue; Broadhurst, Karen
This paper describes a detailed ethnographic study of the design problems of a major national IT system in the UK- The Integrated Children’s System (ICS). The implementation of the ICS has disrupted social work practice and engendered growing professional resistance, prompting a fundamental review of its design. Marshall McLuhan’s concept of chiasmus is a central feature of our analysis of the vicissitudes of ICS. Chiasmus refers to the tendency of any system, when pushed too far, to produce unintended contradictory effects, and is an intrinsic feature of the behaviour of complex, socio-technical systems. The dysfunctions of the ICS provide a pertinent, large-scale example. The ICS constitutes an attempt, via technological means, to re-organize child welfare services in the UK. Whilst aimed at improving child safety, the ICS has had the opposite effect of increasing the potential for error. This chiasmus has been exposed through the multi-site ethnography reported here, which shows how rigidly designed processes, enforced by IT systems, force social work professionals into unsafe investigative and recording practices which increase the risk of errors. The paper ends by proposing an alternative approach to design, based on socio-technical precepts, emphasizing the principles of minimum critical specification, user-centeredness and local autonomy.
Characterization of indigenous chicken production systems in Rwanda.
Mahoro, J; Muasya, T K; Mbuza, F; Habimana, R; Kahi, A K
2017-12-01
Characterization of indigenous chicken (IC) production systems in Rwanda was conducted from November 2015 to January 2016 with the aim of understanding socio-economic characteristics, management of IC, production parameters, feed resources, and constraints faced by farmers rearing IC. A survey involving 206 households was carried out in 5 districts with the highest populations of IC using structured questionnaires. Data were analyzed using SAS software. The results showed that the majority of respondents (62.4%) were males and 37.6% were females. The majority of respondents (83.6%) had formal education. All family members were involved in the chicken husbandry practices. However, women (78%) were highly responsible for IC management activities. The family size averaged 5 persons (ranging 2 to 13) per household. Land was privately owned by farmers (84%) with a mean holding of 0.87 ha per household. The production system was mainly extensive with minimum provision of supplementary feeds. Chickens were being housed in separate houses at night and mating was uncontrolled. Breeding and replacement stocks were mainly sourced from the hatching of eggs using broody hens (60.68% of respondents). There were no vaccination programs, and ecto- and endo-parasites control was done when need arose. Egg production, income generation, meat production, and production of breeding stock were the main reasons of keeping IC. The first 3 main challenges facing IC production were diseases outbreaks, lack of investment capital, and predators. Others challenges, such as feed shortage, thieves, fluctuation of market price, lack of information on poultry rearing, and lack of chicken houses, also were mentioned. The IC production constraints mentioned need urgent mitigation measures to sustain utilization of IC against the changing climatic and economic conditions. Therefore, individual, public institution, and non-governmental organization efforts are required to develop sustainable breeding objectives directed to functions of IC and production challenges faced in the systems. © 2017 Poultry Science Association Inc.
Bentz, Joe; O’Connor, Michael P.; Bednarczyk, Dallas; Coleman, JoAnn; Lee, Caroline; Palm, Johan; Pak, Y. Anne; Perloff, Elke S.; Reyner, Eric; Balimane, Praveen; Brännström, Marie; Chu, Xiaoyan; Funk, Christoph; Guo, Ailan; Hanna, Imad; Herédi-Szabó, Krisztina; Hillgren, Kate; Li, Libin; Hollnack-Pusch, Evelyn; Jamei, Masoud; Lin, Xuena; Mason, Andrew K.; Neuhoff, Sibylle; Patel, Aarti; Podila, Lalitha; Plise, Emile; Rajaraman, Ganesh; Salphati, Laurent; Sands, Eric; Taub, Mitchell E.; Taur, Jan-Shiang; Weitz, Dietmar; Wortelboer, Heleen M.; Xia, Cindy Q.; Xiao, Guangqing; Yabut, Jocelyn; Yamagata, Tetsuo; Zhang, Lei
2013-01-01
A P-glycoprotein (P-gp) IC50 working group was established with 23 participating pharmaceutical and contract research laboratories and one academic institution to assess interlaboratory variability in P-gp IC50 determinations. Each laboratory followed its in-house protocol to determine in vitro IC50 values for 16 inhibitors using four different test systems: human colon adenocarcinoma cells (Caco-2; eleven laboratories), Madin-Darby canine kidney cells transfected with MDR1 cDNA (MDCKII-MDR1; six laboratories), and Lilly Laboratories Cells—Porcine Kidney Nr. 1 cells transfected with MDR1 cDNA (LLC-PK1-MDR1; four laboratories), and membrane vesicles containing human P-glycoprotein (P-gp; five laboratories). For cell models, various equations to calculate remaining transport activity (e.g., efflux ratio, unidirectional flux, net-secretory-flux) were also evaluated. The difference in IC50 values for each of the inhibitors across all test systems and equations ranged from a minimum of 20- and 24-fold between lowest and highest IC50 values for sertraline and isradipine, to a maximum of 407- and 796-fold for telmisartan and verapamil, respectively. For telmisartan and verapamil, variability was greatly influenced by data from one laboratory in each case. Excluding these two data sets brings the range in IC50 values for telmisartan and verapamil down to 69- and 159-fold. The efflux ratio-based equation generally resulted in severalfold lower IC50 values compared with unidirectional or net-secretory-flux equations. Statistical analysis indicated that variability in IC50 values was mainly due to interlaboratory variability, rather than an implicit systematic difference between test systems. Potential reasons for variability are discussed and the simplest, most robust experimental design for P-gp IC50 determination proposed. The impact of these findings on drug-drug interaction risk assessment is discussed in the companion article (Ellens et al., 2013) and recommendations are provided. PMID:23620485
Hardening Logic Encryption against Key Extraction Attacks with Circuit Camouflage
2017-03-01
camouflage; obfuscation; SAT; key extraction; reverse engineering; security; trusted electronics Introduction Integrated Circuit (IC) designs are...Encryption Algorithms”, Hardware Oriented Security and Trust , 2015. 3. Rajendran J., Pino, Y., Sinanoglu, O., Karri, R., “Security Analysis of Logic
1967-09-09
This photograph depicts the F-1 engine firing in the Marshall Space Flight Center’s F-1 Engine Static Test Stand. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. It is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. The foundation of the stand is keyed into the bedrock approximately 40 feet below grade.
Nieto-Torres, Jose L.; DeDiego, Marta L.; Verdiá-Báguena, Carmina; Jimenez-Guardeño, Jose M.; Regla-Nava, Jose A.; Fernandez-Delgado, Raul; Castaño-Rodriguez, Carlos; Alcaraz, Antonio; Torres, Jaume; Aguilella, Vicente M.; Enjuanes, Luis
2014-01-01
Deletion of Severe Acute Respiratory Syndrome Coronavirus (SARS-CoV) envelope (E) gene attenuates the virus. E gene encodes a small multifunctional protein that possesses ion channel (IC) activity, an important function in virus-host interaction. To test the contribution of E protein IC activity in virus pathogenesis, two recombinant mouse-adapted SARS-CoVs, each containing one single amino acid mutation that suppressed ion conductivity, were engineered. After serial infections, mutant viruses, in general, incorporated compensatory mutations within E gene that rendered active ion channels. Furthermore, IC activity conferred better fitness in competition assays, suggesting that ion conductivity represents an advantage for the virus. Interestingly, mice infected with viruses displaying E protein IC activity, either with the wild-type E protein sequence or with the revertants that restored ion transport, rapidly lost weight and died. In contrast, mice infected with mutants lacking IC activity, which did not incorporate mutations within E gene during the experiment, recovered from disease and most survived. Knocking down E protein IC activity did not significantly affect virus growth in infected mice but decreased edema accumulation, the major determinant of acute respiratory distress syndrome (ARDS) leading to death. Reduced edema correlated with lung epithelia integrity and proper localization of Na+/K+ ATPase, which participates in edema resolution. Levels of inflammasome-activated IL-1β were reduced in the lung airways of the animals infected with viruses lacking E protein IC activity, indicating that E protein IC function is required for inflammasome activation. Reduction of IL-1β was accompanied by diminished amounts of TNF and IL-6 in the absence of E protein ion conductivity. All these key cytokines promote the progression of lung damage and ARDS pathology. In conclusion, E protein IC activity represents a new determinant for SARS-CoV virulence. PMID:24788150
Kido, Jun-Ichi; Murakami, Shinya; Kitamura, Masahiro; Yanagita, Manabu; Tabeta, Koichi; Yamazaki, Kazuhisa; Yoshie, Hiromasa; Watanabe, Hisashi; Izumi, Yuichi; Suda, Reiko; Yamamoto, Matsuo; Shiba, Hideki; Fujita, Tsuyoshi; Kurihara, Hidemi; Mizuno, Mitsuharu; Mishima, Akihiro; Kawahara, Nobumasa; Hashimoto, Kazuhiro; Naruishi, Koji; Nagata, Toshihiko
2017-09-06
Calprotectin, an inflammation-related protein, is present in gingival crevicular fluid (GCF) and the determination of calprotectin is useful for diagnosing periodontal diseases. We have recently developed a novel immunochromatographic (IC) chip system (SI-101402) to determine calprotectin levels in GCF. In the present study, the usefulness of this diagnostic system was investigated in patients with periodontal diseases. Thirty-six patients with periodontal diseases participated in this clinical test at multiple centers. Periodontitis sites (n=118) and non-periodontitis (healthy) sites (n=120) were selected after periodontal examination. GCF collection and periodontal examination were performed at baseline, after supragingival and subgingival scaling and root planing. Calprotectin amount in GCF was determined using a novel IC chip system and evaluated as a visual score and an IC reader value. The correlation between GCF calprotectin levels, clinical indicators and changes in calprotectin levels by periodontal treatments were investigated. Receiver operating characteristic (ROC) analysis of IC reader value for GCF calprotectin was performed to predict periodontal diseases. The visual score of GCF calprotectin was highly correlated the IC reader value. IC reader values of GCF calprotectin in periodontitis group were higher than those of healthy group at three dental examination stages and they significantly decreased with periodontal treatments. Visual scores and IC reader values of GCF calprotectin were correlated to the levels of clinical indicators. ROC analysis for GCF calprotectin showed an optimal cutoff value to predict periodontal diseases. Determination of GCF calprotectin using a novel IC chip system is useful for diagnosis of periodontal diseases.
Intratumoral immunocytokine treatment results in enhanced antitumor effects.
Johnson, Erik E; Lum, Hillary D; Rakhmilevich, Alexander L; Schmidt, Brian E; Furlong, Meghan; Buhtoiarov, Ilia N; Hank, Jacquelyn A; Raubitschek, Andrew; Colcher, David; Reisfeld, Ralph A; Gillies, Stephen D; Sondel, Paul M
2008-12-01
Immunocytokines (IC), consisting of tumor-specific monoclonal antibodies fused to the immunostimulatory cytokine interleukin 2 (IL2), exert significant antitumor effects in several murine tumor models. We investigated whether intratumoral (IT) administration of IC provided enhanced antitumor effects against subcutaneous tumors. Three unique ICs (huKS-IL2, hu14.18-IL2, and GcT84.66-IL2) were administered systemically or IT to evaluate their antitumor effects against tumors expressing the appropriate IC-targeted tumor antigens. The effect of IT injection of the primary tumor on a distant tumor was also evaluated. Here, we show that IT injection of IC resulted in enhanced antitumor effects against B16-KSA melanoma, NXS2 neuroblastoma, and human M21 melanoma xenografts when compared to intravenous (IV) IC injection. Resolution of both primary and distant subcutaneous tumors and a tumor-specific memory response were demonstrated following IT treatment in immunocompetent mice bearing NXS2 tumors. The IT effect of huKS-IL2 IC was antigen-specific, enhanced compared to IL2 alone, and dose-dependent. Hu14.18-IL2 also showed greater IT effects than IL2 alone. The antitumor effect of IT IC did not always require T cells since IT IC induced antitumor effects against tumors in both SCID and nude mice. Localization studies using radiolabeled (111)In-GcT84.66-IL2 IC confirmed that IT injection resulted in a higher concentration of IC at the tumor site than IV administration. In conclusion, we suggest that IT IC is more effective than IV administration against palpable tumors. Further testing is required to determine how to potentially incorporate IT administration of IC into an antitumor regimen that optimizes local and systemic anticancer therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, Kedar G.; Pannu, Satinderpall S.
An integrated circuit system having an integrated circuit (IC) component which is able to have its functionality destroyed upon receiving a command signal. The system may involve a substrate with the IC component being supported on the substrate. A module may be disposed in proximity to the IC component. The module may have a cavity and a dissolving compound in a solid form disposed in the cavity. A heater component may be configured to heat the dissolving compound to a point of sublimation where the dissolving compound changes from a solid to a gaseous dissolving compound. A triggering mechanism maymore » be used for initiating a dissolution process whereby the gaseous dissolving compound is allowed to attack the IC component and destroy a functionality of the IC component.« less
Modularized construction of general integrated circuits on individual carbon nanotubes.
Pei, Tian; Zhang, Panpan; Zhang, Zhiyong; Qiu, Chenguang; Liang, Shibo; Yang, Yingjun; Wang, Sheng; Peng, Lian-Mao
2014-06-11
While constructing general integrated circuits (ICs) with field-effect transistors (FETs) built on individual CNTs is among few viable ways to build ICs with small dimension and high performance that can be compared with that of state-of-the-art Si based ICs, this has not been demonstrated owing to the absence of valid and well-tolerant fabrication method. Here we demonstrate a modularized method for constructing general ICs on individual CNTs with different electric properties. A pass-transistor-logic style 8-transistor (8-T) unit is built, demonstrated as a multifunctional function generator with good tolerance to inhomogeneity in the CNTs used and used as a building block for constructing general ICs. As an example, an 8-bits BUS system that is widely used to transfer data between different systems in a computer is constructed. This is the most complicated IC fabricated on individual CNTs to date, containing 46 FETs built on six individual semiconducting CNTs. The 8-T unit provides a good basis for constructing complex ICs to explore the potential and limits of CNT ICs given the current imperfection in available CNT materials and may also be developed into a universal and efficient way for constructing general ICs on ideal CNT materials in the future.
Rationally engineered polymeric cisplatin nanoparticle for improved antitumor efficacy
Paraskar, Abhimanyu; Soni, Shivani; Basu, Sudipta; Chitra, J; Amarasiriwardena; Lupoli, Nicola; Srivats, Shyam; Roy, Rituparna Sinha; Sengupta, Shiladitya
2011-01-01
The use of cisplatin, a first line chemotherapy for most cancers, is dose-limited due to nephrotoxicity. While, this toxicity can be addressed through nanotechnology, previous attempts at engineering cisplatin nanoparticles have been limited by the impact on the potency of cisplatin. Here we report the rational engineering of a novel cisplatin nanoparticle by harnessing a novel polyethylene glycol-functionalized poly-isobutylene-maleic acid (PEG-PIMA) co-polymer, which can complex with cis-platinum (II) through a monocarboxylato and a coordinate bond. We show that this complex self-assembles into a nanoparticle, and exhibit an IC50 = 0.77 ± 0.11μM comparable to that of free cisplatin (IC50 = 0.44 ± 0.09 μM). The nanoparticles are internalized into the endolysosomal compartment of cancer cells, and releases cisplatin in a pH-dependent manner. Furthermore, the nanoparticles exhibited significantly improved antitumor efficacy in a 4T1 breast cancer model in vivo with limited nephrotoxicity, which can be explained by preferential biodistribution in the tumor with reduced kidney concentrations. Our results suggest that the PEG-PIMA-cisplatin nanoparticle can emerge as an attractive solution to the challenges in cisplatin chemotherapy. PMID:21576779
1987-05-01
Federal Aviati6n Regulation (FAR) Part 36. PSIL Preferred Speech Interference Level as specified in AFR 161-35. dB Decibel, Base 10 logarithmic ratio...I IP 1 0 I 1- *P N p 0 - 5V S 4 S r. V 0 l- N N N & N i% OW ta b, in i in n ivWvP1*1v vv A m Am ANN N KNN #ai I I I6 I I " Ic OSI-IS 0 9A N I, fu a t
Dynamical Competition of IC-Industry Clustering from Taiwan to China
NASA Astrophysics Data System (ADS)
Tsai, Bi-Huei; Tsai, Kuo-Hui
2009-08-01
Most studies employ qualitative approach to explore the industrial clusters; however, few research has objectively quantified the evolutions of industry clustering. The purpose of this paper is to quantitatively analyze clustering among IC design, IC manufacturing as well as IC packaging and testing industries by using the foreign direct investment (FDI) data. The Lotka-Volterra system equations are first adopted here to capture the competition or cooperation among such three industries, thus explaining their clustering inclinations. The results indicate that the evolution of FDI into China for IC design industry significantly inspire the subsequent FDI of IC manufacturing as well as IC packaging and testing industries. Since IC design industry lie in the upstream stage of IC production, the middle-stream IC manufacturing and downstream IC packing and testing enterprises tend to cluster together with IC design firms, in order to sustain a steady business. Finally, Taiwan IC industry's FDI amount into China is predicted to cumulatively increase, which supports the industrial clustering tendency for Taiwan IC industry. Particularly, the FDI prediction of Lotka-Volterra model performs superior to that of the conventional Bass model after the forecast accuracy of these two models are compared. The prediction ability is dramatically improved as the industrial mutualism among each IC production stage is taken into account.
Ham, Dong Yeub; Choi, Woo Suk; Song, Sang Hoon; Ahn, Young-Joon; Park, Hyoung Keun; Kim, Hyeong Gon
2016-01-01
Purpose The aim of this study was to evaluate the efficacy of a multimedia informed consent (IC) presentation on the understanding and satisfaction of patients who were scheduled to receive 120-W green-light high-performance system photoselective vaporization of the prostate (HPS-PVP). Materials and Methods A multimedia IC (M-IC) presentation for HPS-PVP was developed. Forty men with benign prostatic hyperplasia who were scheduled to undergo HPS-PVP were prospectively randomized to a conventional written IC group (W-IC group, n=20) or the M-IC group (n=20). The allocated IC was obtained by one certified urologist, followed by a 15-question test (maximum score, 15) to evaluate objective understanding, and questionnaires on subjective understanding (range, 0~10) and satisfaction (range, 0~10) using a visual analogue scale. Results Demographic characteristics, including age and the highest level of education, did not significantly differ between the two groups. No significant differences were found in scores reflecting the objective understanding of HPS-PVP (9.9±2.3 vs. 10.6±2.8, p=0.332) or in subjective understanding scores (7.5±2.1 vs. 8.6±1.7, p=0.122); however, the M-IC group showed higher satisfaction scores than the W-IC group (7.4±1.7 vs. 8.4±1.5, p=0.033). After adjusting for age and educational level, the M-IC group still had significantly higher satisfaction scores. Conclusions M-IC did not enhance the objective knowledge of patients regarding this surgical procedure. However, it improved the satisfaction of patients with the IC process itself. PMID:27169129
Missile Defense Information Technology Small Business Conference
2009-09-01
NetOps Survivability 4 • Supported User Base • Number of Workstations • Number of Servers • Number of Special Circuits • Number of Sites • Number...Contracts, MDIOC • Ground Test (DTC) • MDSEC (SS) • Infrastructure (IC) • BMDS Support (BCT) • JTAAS – SETA • Mod & Sim ( DES ) • Analysis (GML) • Tenants...AUG 09) 4 MDA DOCE Engineering Functions • Design Engineers – Develop detailed design artifacts based on architectural specifications – Coordinate
2016-06-01
engineering and environmental challenges. ERDC develops innovative solutions in civil and military engineering, geospatial sciences, water resources, and... tte rn o f p ea ks , i nd ic at in g th e we t p or tio n of ea ch y ea r, fo llo we d by a s ha rp d ec lin e in to th e dr y s ea so
Brandariz-Nuñez, Alberto; Otero-Romero, Iria; Benavente, Javier; Martinez-Costas, Jose M
2011-09-20
We have recently developed a versatile tagging system (IC-tagging) that causes relocation of the tagged proteins to ARV muNS-derived intracellular globular inclusions. In the present study we demonstrate (i) that the IC-tag can be successfully fused either to the amino or carboxyl terminus of the protein to be tagged and (ii) that IC-tagged proteins are able to interact between them and perform complex reactions that require such interactions while integrated into muNS inclusions, increasing the versatility of the IC-tagging system. Also, our studies with the DsRed protein add some light on the structure/function relationship of the evolution of DsRed chromophore. Copyright © 2011 Elsevier B.V. All rights reserved.
40 CFR 51.119 - Intermittent control systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., 1970, and was operated as specified by the operating system of the ICS before December 31, 1970. (3... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Intermittent control systems. 51.119... Intermittent control systems. (a) The use of an intermittent control system (ICS) may be taken into account in...
40 CFR 51.119 - Intermittent control systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., 1970, and was operated as specified by the operating system of the ICS before December 31, 1970. (3... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Intermittent control systems. 51.119... Intermittent control systems. (a) The use of an intermittent control system (ICS) may be taken into account in...
40 CFR 51.119 - Intermittent control systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., 1970, and was operated as specified by the operating system of the ICS before December 31, 1970. (3... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Intermittent control systems. 51.119... Intermittent control systems. (a) The use of an intermittent control system (ICS) may be taken into account in...
40 CFR 51.119 - Intermittent control systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., 1970, and was operated as specified by the operating system of the ICS before December 31, 1970. (3... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Intermittent control systems. 51.119... Intermittent control systems. (a) The use of an intermittent control system (ICS) may be taken into account in...
40 CFR 51.119 - Intermittent control systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., 1970, and was operated as specified by the operating system of the ICS before December 31, 1970. (3... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Intermittent control systems. 51.119... Intermittent control systems. (a) The use of an intermittent control system (ICS) may be taken into account in...
Reynolds, Penny S; Michael, Mary J; Spiess, Bruce D
2017-02-09
Clinical trial success depends on appropriate management, but practical guidance to trial organisation and planning is lacking. The Incident Command System (ICS) is the 'gold standard' management system developed for managing diverse operations in major incident and public health arenas. It enables effective and flexible management through integration of personnel, procedures, resources, and communications within a common hierarchical organisational structure. Conventional ICS organisation consists of five function modules: Command, Planning, Operations, Logistics, and Finance/Administration. Large clinical trials will require a separate Regulatory Administrative arm, and an Information arm, consisting of dedicated data management and information technology staff. We applied ICS principles to organisation and management of the Prehospital Use of Plasma in Traumatic Haemorrhage (PUPTH) trial. This trial was a multidepartmental, multiagency, randomised clinical trial investigating prehospital administration of thawed plasma on mortality and coagulation response in severely injured trauma patients. We describe the ICS system as it would apply to large clinical trials in general, and the benefits, barriers, and lessons learned in utilising ICS principles to reorganise and coordinate the PUPTH trial. Without a formal trial management structure, early stages of the trial were characterised by inertia and organisational confusion. Implementing ICS improved organisation, coordination, and communication between multiple agencies and service groups, and greatly streamlined regulatory compliance administration. However, unfamiliarity of clinicians with ICS culture, conflicting resource allocation priorities, and communication bottlenecks were significant barriers. ICS is a flexible and powerful organisational tool for managing large complex clinical trials. However, for successful implementation the cultural, psychological, and social environment of trial participants must be accounted for, and personnel need to be educated in the basics of ICS. ClinicalTrials.gov, NCT02303964 . Registered on 28 November 2014.
NASA Astrophysics Data System (ADS)
Ma, Hongjun; Liu, Huajun; Liu, Fang; Zhang, Huahui; Ci, Lu; Shi, Yi; Lei, Lei
2018-01-01
High-Temperature Superconductors (HTS) are potential materials for high-field magnets, low-loss transmission cables, and Superconducting Magnetic Energy Storage (SMES) due to their high upper critical magnetic field (Hc2) and critical temperature (Tc). The critical current (Ic) of HTS, which is one of the most important parameters for superconductor application, depends strongly on the magnetic fields and temperatures. A new Ic measurement system that can carry out accurate Ic measurement for HTS short samples with various temperatures (4.2-80 K), magnetic fields (0-14 T), and angles of the magnetic field (0°-90°) has been developed. The Ic measurement system mainly consists of a measurement holder, temperature-control system, background magnet, test cryostat, data acquisition system, and DC power supply. The accuracy of temperature control is better than ±0.1 K over the 20-80 K range and ±0.05 K when measured below 20 K. The maximum current is over 1000 A with a measurement uncertainty of 1%. The system had been successfully used for YBa2Cu3O7-x(YBCO) tapes Ic determination with different temperatures and magnetic fields.
NASA Astrophysics Data System (ADS)
Sano, Kimikazu; Nagatani, Munehiko; Mutoh, Miwa; Murata, Koichi
This paper is a report on a high ESD breakdown-voltage InP HBT transimpedance amplifier IC for optical video distribution systems. To make ESD breakdown-voltage higher, we designed ESD protection circuits integrated in the TIA IC using base-collector/base-emitter diodes of InP HBTs and resistors. These components for ESD protection circuits have already existed in the employed InP HBT IC process, so no process modifications were needed. Furthermore, to meet requirements for use in optical video distribution systems, we studied circuit design techniques to obtain a good input-output linearity and a low-noise characteristic. Fabricated InP HBT TIA IC exhibited high human-body-model ESD breakdown voltages (±1000V for power supply terminals, ±200V for high-speed input/output terminals), good input-output linearity (less than 2.9-% duty-cycle-distortion), and low noise characteristic (10.7pA/√Hz averaged input-referred noise current density) with a -3-dB-down higher frequency of 6.9GHz. To the best of our knowledge, this paper is the first literature describing InP ICs with high ESD-breakdown voltages.
System and method for interfacing large-area electronics with integrated circuit devices
Verma, Naveen; Glisic, Branko; Sturm, James; Wagner, Sigurd
2016-07-12
A system and method for interfacing large-area electronics with integrated circuit devices is provided. The system may be implemented in an electronic device including a large area electronic (LAE) device disposed on a substrate. An integrated circuit IC is disposed on the substrate. A non-contact interface is disposed on the substrate and coupled between the LAE device and the IC. The non-contact interface is configured to provide at least one of a data acquisition path or control path between the LAE device and the IC.
The quest for solvable multistate Landau-Zener models
Sinitsyn, Nikolai A.; Chernyak, Vladimir Y.
2017-05-24
Recently, integrability conditions (ICs) in mutistate Landau-Zener (MLZ) theory were proposed. They describe common properties of all known solved systems with linearly time-dependent Hamiltonians. Here we show that ICs enable efficient computer assisted search for new solvable MLZ models that span complexity range from several interacting states to mesoscopic systems with many-body dynamics and combinatorially large phase space. This diversity suggests that nontrivial solvable MLZ models are numerous. Additionally, we refine the formulation of ICs and extend the class of solvable systems to models with points of multiple diabatic level crossing.
Methods of instruction of the incident command system and related topics at US veterinary schools.
Smith, Joe S; Kuldau, Gretchen A
2014-12-01
The Incident Command System (ICS) is an adaptable construct designed to streamline response efforts to a disaster or other incident. We aimed to examine the methods used to teach the ICS at US veterinary schools and to explore alternative and novel methods for instruction of this material. A total of 29 US accredited veterinary schools (as of February 2012) were surveyed, and 18 of the 29 schools responded. The ICS and related topics were taught by both classroom methods and online instruction by most of the surveyed schools. Several of the schools used readily available Federal Emergency Management Agency and US Department of Agriculture resources to aid in instruction. Most schools used one course to teach the ICS, and some schools also used unique methods such as field exercises, drills, side-by-side training with disaster response teams, elective courses, extracurricular clubs, and externships to reinforce the ICS and related topics. Some of the surveyed institutions also utilized fourth-year clinical rotations and field deployments during actual disasters as a component of their ICS and emergency response curriculum. The ICS is being taught at some form at a significant number of US veterinary schools. Additional research is needed to evaluate the efficacy of the teaching methods of the ICS in US veterinary schools.
Langut, Yael; Talhami, Alaa; Mamidi, Samarasimhareddy; Shir, Alexei; Zigler, Maya; Joubran, Salim; Sagalov, Anna; Flashner-Abramson, Efrat; Edinger, Nufar; Klein, Shoshana; Levitzki, Alexander
2017-12-26
There is an urgent need for an effective treatment for metastatic prostate cancer (PC). Prostate tumors invariably overexpress prostate surface membrane antigen (PSMA). We designed a nonviral vector, PEI-PEG-DUPA (PPD), comprising polyethylenimine-polyethyleneglycol (PEI-PEG) tethered to the PSMA ligand, 2-[3-(1, 3-dicarboxy propyl)ureido] pentanedioic acid (DUPA), to treat PC. The purpose of PEI is to bind polyinosinic/polycytosinic acid (polyIC) and allow endosomal release, while DUPA targets PC cells. PolyIC activates multiple pathways that lead to tumor cell death and to the activation of bystander effects that harness the immune system against the tumor, attacking nontargeted neighboring tumor cells and reducing the probability of acquired resistance and disease recurrence. Targeting polyIC directly to tumor cells avoids the toxicity associated with systemic delivery. PPD selectively delivered polyIC into PSMA-overexpressing PC cells, inducing apoptosis, cytokine secretion, and the recruitment of human peripheral blood mononuclear cells (PBMCs). PSMA-overexpressing tumors in nonobese diabetic/severe combined immunodeficiency (NOD/SCID) mice with partially reconstituted immune systems were significantly shrunken following PPD/polyIC treatment, in all cases. Half of the tumors showed complete regression. PPD/polyIC invokes antitumor immunity, but unlike many immunotherapies does not need to be personalized for each patient. The potent antitumor effects of PPD/polyIC should spur its development for clinical use.
Langut, Yael; Talhami, Alaa; Mamidi, Samarasimhareddy; Shir, Alexei; Zigler, Maya; Joubran, Salim; Sagalov, Anna; Flashner-Abramson, Efrat; Edinger, Nufar; Klein, Shoshana; Levitzki, Alexander
2017-01-01
There is an urgent need for an effective treatment for metastatic prostate cancer (PC). Prostate tumors invariably overexpress prostate surface membrane antigen (PSMA). We designed a nonviral vector, PEI-PEG-DUPA (PPD), comprising polyethylenimine–polyethyleneglycol (PEI–PEG) tethered to the PSMA ligand, 2-[3-(1, 3-dicarboxy propyl)ureido] pentanedioic acid (DUPA), to treat PC. The purpose of PEI is to bind polyinosinic/polycytosinic acid (polyIC) and allow endosomal release, while DUPA targets PC cells. PolyIC activates multiple pathways that lead to tumor cell death and to the activation of bystander effects that harness the immune system against the tumor, attacking nontargeted neighboring tumor cells and reducing the probability of acquired resistance and disease recurrence. Targeting polyIC directly to tumor cells avoids the toxicity associated with systemic delivery. PPD selectively delivered polyIC into PSMA-overexpressing PC cells, inducing apoptosis, cytokine secretion, and the recruitment of human peripheral blood mononuclear cells (PBMCs). PSMA-overexpressing tumors in nonobese diabetic/severe combined immunodeficiency (NOD/SCID) mice with partially reconstituted immune systems were significantly shrunken following PPD/polyIC treatment, in all cases. Half of the tumors showed complete regression. PPD/polyIC invokes antitumor immunity, but unlike many immunotherapies does not need to be personalized for each patient. The potent antitumor effects of PPD/polyIC should spur its development for clinical use. PMID:29229829
Simultaneous detection of three lily viruses using Triplex IC-RT-PCR.
Zhang, Yubao; Wang, Yajun; Xie, Zhongkui; Yang, Guo; Guo, Zhihong; Wang, Le
2017-11-01
Viruses commonly infecting lily (Lilium spp.) include: Lily symptomless virus (LSV), Cucumber mosaic virus (CMV) and Lily mottle virus (LMoV). These viruses usually co-infect lilies causing severe economic losses in terms of quantity and quality of flower and bulb production around the world. Reliable and precise detection systems need to be developed for virus identification. We describe the development of a triplex immunocapture (IC) reverse transcription (RT) polymerase chain reaction (PCR) assay for the simultaneous detection of LSV, CMV and LMoV. The triplex IC-RT-PCR was compared with a quadruplex RT-PCR assay. Relative to the quadruplex RT-PCR, the specificity of the triplex IC-RT-PCR system for LSV, CMV and LMoV was 100% for field samples. The sensitivity of the triplex IC-RT-PCR system was 99.4%, 81.4% and 98.7% for LSV, CMV and LMoV, respectively. Agreement (κ) between the results obtained from the two tests was 0.968, 0.844 and 0.984 for LSV, CMV and LMoV, respectively. This is the first report of the simultaneous detection of LSV, CMV and LMoV in a triplex IC-RT-PCR assay. In particular we believe this convenient and reliable triplex IC-RT-PCR method could be used routinely for large-scale field surveys or crop health monitoring of lily. Copyright © 2017. Published by Elsevier B.V.
DOT National Transportation Integrated Search
1997-11-01
The Advanced Technology Transit Bus (ATTB), developed under primary funding from : the U.S. DOT/Federal Transit Administration (FTA), currently uses a power plant : based on a natural gas burning IC engine-generator set. FTA is interested in : demons...
BCH codes for large IC random-access memory systems
NASA Technical Reports Server (NTRS)
Lin, S.; Costello, D. J., Jr.
1983-01-01
In this report some shortened BCH codes for possible applications to large IC random-access memory systems are presented. These codes are given by their parity-check matrices. Encoding and decoding of these codes are discussed.
DOT National Transportation Integrated Search
2013-07-29
The John A. Volpe National Transportation Systems Center was asked by the Office of Security of the Maritime Administration to examine the issue of industrial control systems (ICS) security in the Maritime Transportation System (MTS), and to develop ...
Jackson Bar Training Structure Study
2015-05-01
comparison of the one-dimensional bridge hydraulic routines from: HEC - RAS , HEC -2, and WSPRO. Davis, CA: U.S. Army Corps of Engineers, Hydrologic Engineering...ER D C/ CH L TR -1 5- 4 Jackson Bar Training Structure Study Co as ta l a nd H yd ra ul ic s La bo ra to ry Jeremy A. Sharp and...The hydrodynamic model was validated with gage data from the U.S. Geological Survey 02470050 Tombigbee River at Steamplant near Leroy, AL, gage
F-1 engines of Apollo/Saturn V first stage leave trail of flame after liftoff
1968-04-04
S68-27366 (4 April 1968) --- The five F-1 engines of the huge Apollo/Saturn V space vehicle's first (S-IC) stage leave a gigantic trail of flame in the sky above the Kennedy Space Center seconds after liftoff. The launch of the Apollo 6 (Spacecraft 020/Saturn 502) unmanned space mission occurred at 07:00:01.5 (EST), April 4, 1968. This view of the Apollo 6 launch was taken from a chase plane.
F-1 engines of Apollo/Saturn V first stage leave trail of flame after liftoff
1968-04-04
S68-27365 (4 April 1968) --- The five F-1 engines of the huge Apollo/Saturn V space vehicle's first (S-IC) stage leave a gigantic trail of flame in the sky above the Kennedy Space Center seconds after liftoff. The launch of the Apollo 6 (Spacecraft 020/Saturn 502) unmanned space mission occurred at 07:00:01.5 (EST), April 4, 1968. This view of the Apollo 6 launch was taken from a chase plane.
1967-11-01
This image depicts a Boeing worker installing an F-1 engine on the Saturn V S-IC flight stage at the Michoud Assembly Facility (MAF). The Saturn IB and Saturn V first stages were manufactured at the MAF, located 24 kilometers (approximately 15 miles) east of downtown New Orleans, Louisiana. The prime contractors, Chrysler and Boeing, jointly occupied the MAF. The basic manufacturing building boasted 43 acres under one roof. By 1964, NASA added a separate engineering and office building, vertical assembly building, and test stage building.
Micro-cogen AMTEC systems for residential and transportation opportunities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mital, R.; Rasmussen, J.R.; Hunt, T.
1998-07-01
This paper describes the design and anticipated performance of high efficiency AMTEC systems suitable for natural gas fired micro-cogeneration for residential and transportation applications. AMTEC systems have a relatively flat efficiency curve from a few tens of watts to several kilowatts. This unique quality of AMTEC makes it well suited for micro-cogen as opposed to other technologies, such as internal combustion (IC) engines, which lose efficiency at low power levels. AMTEC also offers additional advantages of high efficiency, high reliability, low noise and low emissions. Combustion heated AMTEC cogeneration systems can also be used in trucks and trailers to keepmore » the diesel engines and cabs warm, provide electrical power for charging the battery and maintain power to the electrical systems during stand down periods. A market study indicates that residential micro-cogen units should have a design generating capacity between 0.5--2 kW. AMTEC systems producing 500 W net electric power have been designed and are presently being built. A 350 W prototype unit is being manufactured for a European firm as a trial unit for central heat and power from a home furnace. Modular one kilowatt units are also being designed that will allow combination into multi-kilowatt systems. The results of feasibility studies focused on price/Watt, efficiency, noise, emission, vibrations, expected lifetime and maintenance cost are also presented in this paper.« less
2016-08-10
enable JCS managers to detect advanced cyber attacks, mitigate the effects of those attacks, and recover their networks following an attack. It also... managers of ICS networks to Detect, Mitigate, and Recover from nation-state-level cyber attacks (strategic, deliberate, well-trained, and funded...Successful Detection of cyber anomalies is best achieved when IT and ICS managers remain in close coordination. The Integrity Checks Table
Superstorm Sandy: Implications For Designing A PostCyber Attack Power Restoration System
2016-03-31
for such progress. Phillip Allison, “ Cloak and Secure Your Critical Infrastructure, ICS and SCADA Systems: Building Security into Your Industrial...TechSvcs/Multi-stateFleetResponseWorkshopReport-02-21-13.pdf. Allison, Phillip. “ Cloak and Secure Your Critical Infrastructure, ICS and SCADA Systems
1960-01-01
This chart provides the vital statistics for the F-1 rocket engine. Developed by Rocketdyne, under the direction of the Marshall Space Flight Center, the F-1 engine was utilized in a cluster of five engines to propel the Saturn V's first stage, the S-IC. Liquid oxygen and kerosene were used as its propellant. Initially rated at 1,500,000 pounds of thrust, the engine was later uprated to 1,522,000 pounds of thrust after the third Saturn V launch (Apollo 8, the first marned Saturn V mission) in December 1968. The cluster of five F-1 engines burned over 15 tons of propellant per second, during its two and one-half minutes of operation, to take the vehicle to a height of about 36 miles and to a speed of about 6,000 miles per hour.
IC [Interior Communications] Electrician 3 and 2: Rate Training Manual. Revised.
ERIC Educational Resources Information Center
Naval Education and Training Command, Pensacola, FL.
The rate training manual provides information related to the tasks assigned to the Interior Communications (IC) Electricians Third and Second Class who operate and maintain the interior communications systems and associated equipment. Chapter one discusses career challenges for the IC Electrician in terms of responsibilities, advancement…
The Incident Command System: a literature review.
Jensen, Jessica; Thompson, Steven
2016-01-01
Given the foundational and the fundamental role that the Incident Command System (ICS) is intended to play in on-scene response efforts across the United States, it is important to determine what is known about the system and how this is known. Accordingly, this study addresses the following research question: 'How has research explored the ICS?'. To probe this question, a methodological review of the scant, but widening, pool of research literature directly related to the ICS was conducted. This paper reports on the findings of the analysis related to the focus, theoretical frameworks, population and sampling, methods, results, and conclusions of the existing research literature. While undertaken using different methodological approaches, the ICS research suggests that the system may be limited in its usefulness. In addition, the paper discusses the implications of the research for the state of knowledge of the system and for the direction of future research. © 2016 The Author(s). Disasters © Overseas Development Institute, 2016.
Multi-Phase Combustion and Transport Processes Under the Influence of Acoustic Excitation
2014-01-01
membrane and fibre - type regime. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 1.9 A convective shear layer diagrammed in the...Experimental and Theoretical Resonant Frequencies . . . . . . . . . . . . 73 2.2 Fuel Properties ...the presence of acoustic forcing as their usage is increasingly diversified. Although the IC engine, the most popular biofuels application, features
Removal of DNT from Wastewaters at Radford Army Ammunition Plant
1991-03-31
appi~cable) U.S. Armty Corps of EngineersI ITEnvronenta Prgras, ic. ____________Toxic an’d Hazardous Material-, zec 6ý.. ADDPLSS (Crty, State. and... Peter Hartmann is RAAP’s Technical Analytical laboratory supervisor and is responsible for tracking analytical progress and ensuring timely completion
Adoption and supply of a distributed energy technology
NASA Astrophysics Data System (ADS)
Strachan, Neil Douglas
2000-12-01
Technical and economic developments in distributed generation (DG) represent an opportunity for a radically different energy market paradigm, and potentially significant cuts in global carbon emissions. This thesis investigates DG along two interrelated themes: (1) Early adoption and supply of the DG technology of internal combustion (IC) engine cogeneration. (2) Private and social cost implications of DG for private investors and within an energy system. IC engine cogeneration of both power and heat has been a remarkable success in the Netherlands with over 5,000 installations and 1,500MWe of installed capacity by 1997. However, the technology has struggled in the UK with an installed capacity of 110Mwe, fulfilling only 10% of its large estimated potential. An investment simulation model of DG investments in the UK and Netherlands was used, together with analysis of site level data on all DG adoptions from 1985 through 1997. In the UK over 60% of the early installations were sized too small (<140kWe) to be economically attractive (suppliers made their money with maintenance contracts). In the Netherlands, most facilities were sized well above the economic size threshold of 100kWe (lower due to reduced operating and grid connection costs). Institutional players were key in improved sizing of DG. Aided by energy market and CO2 reduction regulatory policy, Dutch distributions utilities played a proactive role in DG. This involved joint ventures with engine cogen suppliers and users, offering improved electricity buy-back tariffs and lower connection costs. This has allowed flexible operation of distributed generation, especially in electricity sales to the grid. Larger units can be sized for on-site heat requirements with electricity export providing revenue and aiding in management of energy networks. A comparison of internal and external costs of three distributed and three centralized generation technologies over a range of heat to power ratios (HPR) was made. Micro-turbines were found to be the lowest cost technology, especially at higher heat loads. Engines are also very competitive providing their NOx and CO emissions are controlled. A cost optimization program was used to develop an optimal green-field supply mix for Florida and New York. (Abstract shortened by UMI.)
Installation of C-6533(XE-2)/ARC ICS in UH-1H helicopter
NASA Astrophysics Data System (ADS)
Hnat, J. A.
1980-07-01
This report documents the results of the installation of the C-6533(XE-2)/ARC ICS in UH-1H helicopter. Installation was performed at the AEL, Inc., Monmouth County Airport facility. Design of each installation was coordinated and approved by the Government. The mechanical and electrical installation drawings for the helicopter are attached as Appendix A of this report. The new ICS system consisted of new cabling, new intercoms and helmets rewired with new microphones. All four crew stations of the helicopter were reconfigured with the new system. Existing cabling for the standard ICS system remained in the aircraft but was securely stowed for later restoration of the aircraft. The helmets (4) were rewired using separate jacks for headphones and microphone lines. Transmit and receive cables were installed in the aircraft with a minimum separation of one inch between cables. A junction box was fabricated and installed on the aft end of the console to house the fan-out terminal strips. Transmit and receive lines' separation was maintained in the junction box. During the test phase the onboard radios were used with the new ICS system.
Quantum-engineered interband cascade photovoltaic devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Razeghi, Manijeh; Tournié, Eric; Brown, Gail J.
2013-12-18
Quantum-engineered multiple stage photovoltaic (PV) devices are explored based on InAs/GaSb/AlSb interband cascade (IC) structures. These ICPV devices employ multiple discrete absorbers that are connected in series by widebandgap unipolar barriers using type-II heterostructure interfaces for facilitating carrier transport between cascade stages similar to IC lasers. The discrete architecture is beneficial for improving the collection efficiency and for spectral splitting by utilizing absorbers with different bandgaps. As such, the photo-voltages from each individual cascade stage in an ICPV device add together, creating a high overall open-circuit voltage, similar to conventional multi-junction tandem solar cells. Furthermore, photo-generated carriers can be collectedmore » with nearly 100% efficiency in each stage. This is because the carriers travel over only a single cascade stage, designed to be shorter than a typical diffusion length. The approach is of significant importance for operation at high temperatures where the diffusion length is reduced. Here, we will present our recent progress in the study of ICPV devices, which includes the demonstration of ICPV devices at room temperature and above with narrow bandgaps (e.g. 0.23 eV) and high open-circuit voltages. © (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.« less
Study on Mine Emergency Mechanism based on TARP and ICS
NASA Astrophysics Data System (ADS)
Xi, Jian; Wu, Zongzhi
2018-01-01
By analyzing the experiences and practices of mine emergency in China and abroad, especially the United States and Australia, normative principle, risk management principle and adaptability principle of constructing mine emergency mechanism based on Trigger Action Response Plans (TARP) and Incident Command System (ICS) are summarized. Classification method, framework, flow and subject of TARP and ICS which are suitable for the actual situation of domestic mine emergency are proposed. The system dynamics model of TARP and ICS is established. The parameters such as evacuation ratio, response rate, per capita emergency capability and entry rate of rescuers are set up. By simulating the operation process of TARP and ICS, the impact of these parameters on the emergency process are analyzed, which could provide a reference and basis for building emergency capacity, formulating emergency plans and setting up action plans in the emergency process.
Strength and fatigue of NT551 silicon nitride and NT551 diesel exhaust valves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andrews, M.J.; Werezczak, A.A.; Kirkland, T.P.
2000-02-01
The content of this report is excerpted from Mark Andrew's Ph.D. Thesis (Andrews, 1999), which was funded by a DOE/OTT High Temperature Materials Laboratory Graduate Fellowship. It involves the characterization of NT551 and valves fabricated with it. The motivations behind using silicon nitride (Si{sub 3}N{sub 4}) as an exhaust valve for a diesel engine are presented in this section. There are several economic factors that have encouraged the design and implementation of ceramic components for internal combustion (IC) engines. The reasons for selecting the diesel engine valve for this are also presented.
1994-04-01
1 lfm ýA a I - @0 38Ud U 0 E loll I0 F4J O 3Uv ~:~3 Igaas .1c % jWC (9 Um IDP. 0 di d0 1.00 00 .d .d d V d d~ di dI C-14 rM D0209- II dUmW o iNc cl...5C15-1 (In River) I FIGURE E-6. MEASUREMENT POINT AT TRANSMISSION UNE; 5C15-1. E-9 IITRI D06209-1 I I 0CS I C .00o tD I I- U, I S IcEoE 0 E0 a-0
1970-01-22
This Saturn V S-II (second) stage is being lifted into position for a test at the Vehicle Assembly Building at the Kennedy Space Center. When the Saturn V booster stage (S-IC) burned out and dropped away, power for the Saturn was provided by the 82-foot-long and 33-foot-diameter S-II stage. Developed by the Space Division of North American Aviation under the direction of the Marshall Space Flight Center, the stage utilized five J-2 engines, each producing 200,000 pounds of thrust. The engines used liquid oxygen and liquid hydrogen as propellants. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.
Tuberculosis diagnostic delay and therapy outcomes of non-national migrants in Tel Aviv, 1998-2008.
Mor, Z; Kolb, H; Lidji, M; Migliori, Gb; Leventhal, A
2013-03-21
Non-national migrants have limited access to medical therapy. This study compares diagnostic delay and treatment outcomes of non-insured non-national migrants (NINNM) with insured Israeli citizens (IC) in the Tel Aviv tuberculosis (TB) clinic between 1998 and 2008. Patient delay was the time from symptoms onset to doctor's visit, while system delay was measured from doctor visit to anti-TB therapy administration. We randomly sampled 222 NINNM and 265 IC. NINNM were younger than IC, had lower male to female ratio and fewer smoked. They had less drug/alcohol abuse, more cavitations on chest radiography, longer patient and shorter system delay. Mean patient and system delays of all patients were 25 ± 14 and 79 ± 42 days, respectively. In multivariate analysis, being NINNM, asymptomatic or smoking predicted longer patient delay, while being asymptomatic or having additional co-morbidity predicted longer system delay. Treatment success in sputum smear-positive pulmonary TB NINNM was 81% and 95.7% in IC (p=0.01). Treatment success was not associated with patient or system delay. In multivariate analysis, work security and treatment adherence predicted treatment success. NINNM had longer patient delay and worse therapy outcome, while IC had longer system delay. Both delays should be reduced. NINNM should be informed that TB therapy is free and unlinked with deportation.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-28
... Subcommittee On Digital I&C Systems The ACRS Subcommittee on Digital Instrumentation and Control (DI&C) Systems... the area of Digital Instrumentation and Control (DI&C) Probabilistic Risk Assessment (PRA). Topics... software reliability methods (QSRMs), NUREG/CR--6997, ``Modeling a Digital Feedwater Control System Using...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rades, Dirk, E-mail: Rades.Dirk@gmx.net; Dziggel, Liesa; Haatanen, Tiina
2011-07-15
Purpose: To create and validate scoring systems for intracerebral control (IC) and overall survival (OS) of patients irradiated for brain metastases. Methods and Materials: In this study, 1,797 patients were randomly assigned to the test (n = 1,198) or the validation group (n = 599). Two scoring systems were developed, one for IC and another for OS. The scores included prognostic factors found significant on multivariate analyses. Age, performance status, extracerebral metastases, interval tumor diagnosis to RT, and number of brain metastases were associated with OS. Tumor type, performance status, interval, and number of brain metastases were associated with IC.more » The score for each factor was determined by dividing the 6-month IC or OS rate (given in percent) by 10. The total score represented the sum of the scores for each factor. The score groups of the test group were compared with the corresponding score groups of the validation group. Results: In the test group, 6-month IC rates were 17% for 14-18 points, 49% for 19-23 points, and 77% for 24-27 points (p < 0.0001). IC rates in the validation group were 19%, 52%, and 77%, respectively (p < 0.0001). In the test group, 6-month OS rates were 9% for 15-19 points, 41% for 20-25 points, and 78% for 26-30 points (p < 0.0001). OS rates in the validation group were 7%, 39%, and 79%, respectively (p < 0.0001). Conclusions: Patients irradiated for brain metastases can be given scores to estimate OS and IC. IC and OS rates of the validation group were similar to the test group demonstrating the validity and reproducibility of both scores.« less
α-Intercalated cells defend the urinary system from bacterial infection.
Paragas, Neal; Kulkarni, Ritwij; Werth, Max; Schmidt-Ott, Kai M; Forster, Catherine; Deng, Rong; Zhang, Qingyin; Singer, Eugenia; Klose, Alexander D; Shen, Tian Huai; Francis, Kevin P; Ray, Sunetra; Vijayakumar, Soundarapandian; Seward, Samuel; Bovino, Mary E; Xu, Katherine; Takabe, Yared; Amaral, Fábio E; Mohan, Sumit; Wax, Rebecca; Corbin, Kaitlyn; Sanna-Cherchi, Simone; Mori, Kiyoshi; Johnson, Lynne; Nickolas, Thomas; D'Agati, Vivette; Lin, Chyuan-Sheng; Qiu, Andong; Al-Awqati, Qais; Ratner, Adam J; Barasch, Jonathan
2014-07-01
α-Intercalated cells (A-ICs) within the collecting duct of the kidney are critical for acid-base homeostasis. Here, we have shown that A-ICs also serve as both sentinels and effectors in the defense against urinary infections. In a murine urinary tract infection model, A-ICs bound uropathogenic E. coli and responded by acidifying the urine and secreting the bacteriostatic protein lipocalin 2 (LCN2; also known as NGAL). A-IC-dependent LCN2 secretion required TLR4, as mice expressing an LPS-insensitive form of TLR4 expressed reduced levels of LCN2. The presence of LCN2 in urine was both necessary and sufficient to control the urinary tract infection through iron sequestration, even in the harsh condition of urine acidification. In mice lacking A-ICs, both urinary LCN2 and urinary acidification were reduced, and consequently bacterial clearance was limited. Together these results indicate that A-ICs, which are known to regulate acid-base metabolism, are also critical for urinary defense against pathogenic bacteria. They respond to both cystitis and pyelonephritis by delivering bacteriostatic chemical agents to the lower urinary system.
Cano, Isaac; Alonso, Albert; Hernandez, Carme; Burgos, Felip; Barberan-Garcia, Anael; Roldan, Jim; Roca, Josep
2015-06-01
Extensive deployment and sustainability of integrated care services (ICS) constitute an unmet need to reduce the burden of chronic conditions. The European Union project NEXES (2008-2013) assessed the deployment of four ICS encompassing the spectrum of severity of chronic patients. The current study aims to (i) describe the open source Adaptive Case Management (ACM) system (Linkcare®) developed to support the deployment of ICS at the level of healthcare district; (ii) to evaluate its performance; and, (iii) to identify key challenges for regional deployment of ICS. We first defined a conceptual model for ICS management and execution composed of five main stages. We then specified an associated logical model considering the dynamic runtime of ACM. Finally, we implemented the four ICS as a physical model with an ICS editor to allow professionals (case managers) to play active roles in adapting the system to their needs. Instances of ICS were then run in Linkcare®. Four ICS provided a framework for evaluating the system: Wellness and Rehabilitation (W&R) (number of patients enrolled in the study (n)=173); Enhanced Care (EC) in frail chronic patients to prevent hospital admissions, (n=848); Home Hospitalization and Early Discharge (HH/ED) (n=2314); and, Support to remote diagnosis (Support) (n=7793). The method for assessment of telemedicine applications (MAST) was used for iterative evaluation. Linkcare® supports ACM with shared-care plans across healthcare tiers and offers integration with provider-specific electronic health records. Linkcare® successfully contributed to the deployment of the four ICS: W&R facilitated long-term sustainability of training effects (p<0.01) and active life style (p<0.03); EC showed significant positive outcomes (p<0.05); HH/ED reduced on average 5 in-hospital days per patient with a 30-d re-admission rate of 10%; and, Support, enhanced community-based quality forced spirometry testing (p<0.01). Key challenges for regional deployment of personalized care were identified. Linkcare® provided the required functionalities to support integrated care adopting an ACM model, and it showed adaptive potential for its implementation in different health scenarios. The research generated strategies that contributed to face the challenges of the transition toward personalized medicine for chronic patients. Copyright © 2015 Elsevier Inc. All rights reserved.
Gray, Aaron D; Willis, Brad W; Skubic, Marjorie; Huo, Zhiyu; Razu, Swithin; Sherman, Seth L; Guess, Trent M; Jahandar, Amirhossein; Gulbrandsen, Trevor R; Miller, Scott; Siesener, Nathan J
Noncontact anterior cruciate ligament (ACL) injury in adolescent female athletes is an increasing problem. The knee-ankle separation ratio (KASR), calculated at initial contact (IC) and peak flexion (PF) during the drop vertical jump (DVJ), is a measure of dynamic knee valgus. The Microsoft Kinect V2 has shown promise as a reliable and valid marker-less motion capture device. The Kinect V2 will demonstrate good to excellent correlation between KASR results at IC and PF during the DVJ, as compared with a "gold standard" Vicon motion analysis system. Descriptive laboratory study. Level 2. Thirty-eight healthy volunteer subjects (20 male, 18 female) performed 5 DVJ trials, simultaneously measured by a Vicon MX-T40S system, 2 AMTI force platforms, and a Kinect V2 with customized software. A total of 190 jumps were completed. The KASR was calculated at IC and PF during the DVJ. The intraclass correlation coefficient (ICC) assessed the degree of KASR agreement between the Kinect and Vicon systems. The ICCs of the Kinect V2 and Vicon KASR at IC and PF were 0.84 and 0.95, respectively, showing excellent agreement between the 2 measures. The Kinect V2 successfully identified the KASR at PF and IC frames in 182 of 190 trials, demonstrating 95.8% reliability. The Kinect V2 demonstrated excellent ICC of the KASR at IC and PF during the DVJ when compared with the Vicon system. A customized Kinect V2 software program demonstrated good reliability in identifying the KASR at IC and PF during the DVJ. Reliable, valid, inexpensive, and efficient screening tools may improve the accessibility of motion analysis assessment of adolescent female athletes.
Sensitivity recovery for the AX-PET prototype using inter-crystal scattering events
NASA Astrophysics Data System (ADS)
Gillam, John E.; Solevi, Paola; Oliver, Josep F.; Casella, Chiara; Heller, Matthieu; Joram, Christian; Rafecas, Magdalena
2014-08-01
The development of novel detection devices and systems such as the AX-positron emission tomography (PET) demonstrator often introduce or increase the measurement of atypical coincidence events such as inter-crystal scattering (ICS). In more standard systems, ICS events often go undetected and the small measured fraction may be ignored. As the measured quantity of such events in the data increases, so too does the importance of considering them during image reconstruction. Generally, treatment of ICS events will attempt to determine which of the possible candidate lines of response (LoRs) correctly determine the annihilation photon trajectory. However, methods of assessment often have low success rates or are computationally demanding. In this investigation alternative approaches are considered. Experimental data was taken using the AX-PET prototype and a NEMA phantom. Three methods of ICS treatment were assessed—each of which considered all possible candidate LoRs during image reconstruction. Maximum likelihood expectation maximization was used in conjunction with both standard (line-like) and novel (V-like in this investigation) detection responses modeled within the system matrix. The investigation assumed that no information other than interaction locations was available to distinguish between candidates, yet the methods assessed all provided means by which such information could be included. In all cases it was shown that the signal to noise ratio is increased using ICS events. However, only one method, which used full modeling of the ICS response in the system matrix—the V-like model—provided enhancement in all figures of merit assessed in this investigation. Finally, the optimal method of ICS incorporation was demonstrated using data from two small animals measured using the AX-PET demonstrator.
Development of voice navigation system for the visually impaired by using IC tags.
Takatori, Norihiko; Nojima, Kengo; Matsumoto, Masashi; Yanashima, Kenji; Magatani, Kazushige
2006-01-01
There are about 300,000 visually impaired persons in Japan. Most of them are old persons and, cannot become skillful in using a white cane, even if they make effort to learn how to use a white cane. Therefore, some guiding system that supports the independent activities of the visually impaired are required. In this paper, we will describe about a developed white cane system that supports the independent walking of the visually impaired in the indoor space. This system is composed of colored navigation lines that include IC tags and an intelligent white cane that has a navigation computer. In our system colored navigation lines that are put on the floor of the target space from the start point to the destination and IC tags that are set at the landmark point are used for indication of the route to the destination. The white cane has a color sensor, an IC tag transceiver and a computer system that includes a voice processor. This white cane senses the navigation line that has target color by a color sensor. When a color sensor finds the target color, the white cane informs a white cane user that he/she is on the navigation line by vibration. So, only following this vibration, the user can reach the destination. However, at some landmark points, guidance is necessary. At these points, an IC tag is set under the navigation line. The cane makes communication with the tag and informs the user about the land mark pint by pre recorded voice. Ten normal subjects who were blindfolded were tested with our developed system. All of them could walk along navigation line. And the IC tag information system worked well. Therefore, we have concluded that our system will be a very valuable one to support activities of the visually impaired.
Sirc-cvs cytotoxicity test: an alternative for predicting rodent acute systemic toxicity.
Kitagaki, Masato; Wakuri, Shinobu; Hirota, Morihiko; Tanaka, Noriho; Itagaki, Hiroshi
2006-10-01
An in vitro crystal violet staining method using the rabbit cornea-derived cell line (SIRC-CVS) has been developed as an alternative to predict acute systemic toxicity in rodents. Seventy-nine chemicals, the in vitro cytotoxicity of which was already reported by the Multicenter Evaluation of In vitro Toxicity (MEIC) and ICCVAM/ECVAM, were selected as test compounds. The cells were incubated with the chemicals for 72 hrs and the IC(50) and IC(35) values (microg/mL) were obtained. The results were compared to the in vivo (rat or mouse) "most toxic" oral, intraperitoneal, subcutaneous and intravenous LD(50) values (mg/kg) taken from the RTECS database for each of the chemicals by using Pearson's correlation statistics. The following parameters were calculated: accuracy, sensitivity, specificity, prevalence, positive predictability, and negative predictability. Good linear correlations (Pearson's coefficient; r>0.6) were observed between either the IC(50) or the IC(35) values and all the LD(50) values. Among them, a statistically significant high correlation (r=0.8102, p<0.001) required for acute systemic toxicity prediction was obtained between the IC(50) values and the oral LD(50) values. By using the cut-off concentrations of 2,000 mg/kg (LD(50)) and 4,225 microg/mL (IC(50)), no false negatives were observed, and the accuracy was 84.8%. From this, it is concluded that this method could be used to predict the acute systemic toxicity potential of chemicals in rodents.
Studies of new media radiation induced laser
NASA Technical Reports Server (NTRS)
Han, K. S.; Shiu, Y. J.; Raju, S. R.; Hwang, I. H.; Tabibi, B.
1984-01-01
Various lasants were investigated especially, 2-iodohepafluoropropane (i-C3F7I) for the direct solar pumped lasers. Optical pumping of iodine laser was achieved using a small flashlamp. Using i-C3F7I as a laser gain medium, threshold inversion density, small signal gain, and laser performance at the elevated temperature were measured. The experimental results and analysis are presented. The iodine laser kinetics of the C3F7I and IBr system were numerically simulated. The concept of a direct solar-pumped laser amplifier using (i-C3F7I) as the laser material was evaluated and several kinetic coefficients for i-C3F7I laser system were reexamined. The results are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kisner, Roger A; Melin, Alexander M; Burress, Timothy A
The overall project objective is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant components. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration vehicle. The project s focus is not primarily on pump design, but instead is on methods to deeply embed I&C within a pump system. However, because the I&C is intimately part of the basic millisecond-by-millisecond functioning of the pump, the I&C design cannot proceed in isolation from the other aspects of the pump. The pumpmore » will not function if the characteristics of the I&C are not embedded within the design because the I&C enables performance of the basic function rather than merely monitoring quasi-stable performance. Traditionally, I&C has been incorporated in nuclear power plant (NPP) components after their design is nearly complete; adequate performance was obtained through over-design. This report describes the progress and status of the project and provides a conceptual design overview for the embedded I&C pump.« less
Plasticity of serotonergic innervation of the inferior colliculus in mice following acoustic trauma
Papesh, Melissa A.; Hurley, Laura M.
2012-01-01
Acoustic trauma often results in permanent damage to the cochlea, triggering changes in processing within central auditory structures such as the inferior colliculus (IC). The serotonergic neuromodulatory system, present in the IC, is responsive to chronic changes in the activity of sensory systems. The current study investigated whether the density of serotonergic innervation in the IC is changed following acoustic trauma. The trauma stimulus consisted of an 8 kHz pure tone presented at a level of 113 dB SPL for six consecutive hours to anesthetized CBA/J mice. Following a minimum recovery period of three weeks, serotonergic fibers were visualized via histochemical techniques targeting the serotonin reuptake transporter (SERT) and quantified using stereologic probes. SERT-positive fiber densities were then compared between the traumatized and protected hemispheres of unilaterally traumatized subjects and those of controls. A significant effect of acoustic trauma was found between the hemispheres of unilaterally traumatized subjects such that the IC contralateral to the ear of exposure contained a lower density of SERT-positive fibers than the IC ipsilateral to acoustic trauma. No significant difference in density was found between the hemispheres of control subjects. Additional dimensions of variability in serotonergic fibers were seen among subdivisions of the IC and with age. The central IC had a slightly but significantly lowered density of serotonergic fibers than other subdivisions of the IC, and serotonergic fibers also declined with age. Overall, the results indicate that acoustic trauma is capable of producing modest but significant decreases in the density of serotonergic fibers innervating the IC. PMID:22101024
Wygant, Ira O; Jamal, Nafis S; Lee, Hyunjoo J; Nikoozadeh, Amin; Oralkan, Omer; Karaman, Mustafa; Khuri-Yakub, Butrus T
2009-10-01
State-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array with integrated circuitry eliminates bulky cables connecting the elements of the transducer array to a separate system of electronics. Furthermore, preamplifiers located close to the array can lead to improved receive sensitivity. A combined IC and transducer array can lead to a portable, high-performance, and inexpensive 3-D ultrasound imaging system. This paper presents an IC flip-chip bonded to a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array for 3-D ultrasound imaging. The IC includes a transmit beamformer that generates 25-V unipolar pulses with programmable focusing delays to 224 of the 256 transducer elements. One-shot circuits allow adjustment of the pulse widths for different ultrasound transducer center frequencies. For receiving reflected ultrasound signals, the IC uses the 32-elements along the array diagonals. The IC provides each receiving element with a low-noise 25-MHz-bandwidth transimpedance amplifier. Using a field-programmable gate array (FPGA) clocked at 100 MHz to operate the IC, the IC generated properly timed transmit pulses with 5-ns accuracy. With the IC flip-chip bonded to a CMUT array, we show that the IC can produce steered and focused ultrasound beams. We present 2-D and 3-D images of a wire phantom and 2-D orthogonal cross-sectional images (Bscans) of a latex heart phantom.
Giuliano, Ryan J; Roos, Leslie E; Farrar, Jessica D; Skowron, Elizabeth A
2018-04-01
A child's cumulative risk for early exposure to stress has been linked to alterations of self-regulation outcomes, including neurobiological correlates of inhibitory control (IC). We examined whether children's ability to engage the parasympathetic nervous system impacts how risk affects IC. Children ages 3-5 years completed two laboratory measures of IC while respiratory sinus arrhythmia (RSA) was measured, indexing parasympathetic activity. Children with greater risk demonstrated lower IC; risk also moderated associations between RSA reactivity and IC. For children with less risk, greater RSA withdrawal during IC tasks was associated with better IC. In contrast, greater risk was associated with poor IC, regardless of RSA withdrawal. Effects of risk were more pronounced for cumulative than individual measures. Results suggest that cumulative risk exposure disrupts connectivity between physiological and behavioral components of self-regulation in early childhood. Parasympathetic withdrawal to cognitive tasks may be less relevant for performance in developmental samples experiencing greater life stress. © 2018 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-01-01
This paper, presented at the IEEE Green Technologies Conference 2013, describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1 (TM). The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to testmore » the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-01-01
This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
A packet switched communications system for GRO
NASA Astrophysics Data System (ADS)
Husain, Shabu; Yang, Wen-Hsing; Vadlamudi, Rani; Valenti, Joseph
1993-11-01
This paper describes the packet switched Instrumenters Communication System (ICS) that was developed for the Command Management Facility at GSFC to support the Gamma Ray Observatory (GRO) spacecraft. The GRO ICS serves as a vital science data acquisition link to the GRO scientists to initiate commands for their spacecraft instruments. The system is ready to send and receive messages at any time, 24 hours a day and seven days a week. The system is based on X.25 and the International Standard Organization's (ISO) 7-layer Open Systems Interconnection (OSI) protocol model and has client and server components. The components of the GRO ICS are discussed along with how the Communications Subsystem for Interconnection (CSFI) and Network Control Program Packet Switching Interface (NPSI) software are used in the system.
Aytac, Zeynep; Yildiz, Zehra Irem; Kayaci-Senirmak, Fatma; San Keskin, Nalan Oya; Kusku, Semran Ipek; Durgun, Engin; Tekinay, Turgay; Uyar, Tamer
2016-10-05
We have proposed a new strategy for preparing free-standing nanofibrous webs from an inclusion complex (IC) of a well-known flavor/fragrance compound (limonene) with three modified cyclodextrins (HPβCD, MβCD, and HPγCD) via electrospinning (CD/limonene-IC-NFs) without using a polymeric matrix. The experimental and computational modeling studies proved that the stoichiometry of the complexes was 1:1 for CD/limonene systems. MβCD/limonene-IC-NF released much more limonene at 37, 50, and 75 °C than HPβCD/limonene-IC-NF and HPγCD/limonene-IC-NF because of the greater amount of preserved limonene. Moreover, MβCD/limonene-IC-NF has released only 25% (w/w) of its limonene, whereas HPβCD/limonene-IC-NF and HPγCD/limonene-IC-NF released 51 and 88% (w/w) of their limonene in 100 days, respectively. CD/limonene-IC-NFs exhibited high antibacterial activity against E. coli and S. aureus. The water solubility of limonene increased significantly and CD/limonene-IC-NFs were dissolved in water in a few seconds. In brief, CD/limonene-IC-NFs with fast-dissolving character enhanced the thermal stability and prolonged the shelf life along with antibacterial properties could be quite applicable in food and oral care applications.
Blasier, Kiev R.; Humsi, Michael K.; Ha, Junghoon; Ross, Mitchell W.; Smiley, W. Russell; Inamdar, Nirja A.; Mitchell, David J.; Lo, Kevin W.-H.; Pfister, K. Kevin
2014-01-01
Cytoplasmic dynein is a multi-subunit motor protein responsible for intracellular cargo transport toward microtubule minus ends. There are multiple isoforms of the dynein intermediate chain (DYNC1I, IC) which is encoded by two genes. One way to regulate cytoplasmic dynein is by IC phosphorylation. The IC-2C isoform is expressed in all cells and the functional significance of phosphorylation on IC-2C serine 84 was investigated using live cell imaging of fluorescent protein-tagged wild type IC-2C (WT) and phospho- and dephospho-mimic mutant isoforms in axonal transport model systems. Both mutations modulated dynein functional properties. The dephospho-mimic mutant IC-2C S84A had greater co-localization with mitochondria than IC-2C wild-type (WT) or the phospho-mimic mutant IC-2C S84D. The dephospho-mimic mutant IC-2C S84A was also more likely to be motile than the phospho-mimic mutant IC-2C S84D or IC-2C WT. In contrast, the phospho-mimic mutant IC-2C S84D mutant was more likely to move in the retrograde direction than was the IC-2C S84A mutant. The phospho-mimic IC-2C S84D was also as likely as IC-2C WT to co-localize with mitochondria. Both the S84D phospho- and S84A, dephospho-mimic mutants were found to be capable of microtubule minus end directed (retrograde) movement in axons. They were also observed to be passively transported in the anterograde direction. These data suggest that the IC-2C S84 has a role in modulating dynein properties. PMID:24798412
30 CFR 57.22210 - In-line filters (I-C mines).
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false In-line filters (I-C mines). 57.22210 Section... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22210 In-line filters (I-C mines). Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of...
30 CFR 57.22210 - In-line filters (I-C mines).
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false In-line filters (I-C mines). 57.22210 Section... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22210 In-line filters (I-C mines). Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of...
30 CFR 57.22210 - In-line filters (I-C mines).
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false In-line filters (I-C mines). 57.22210 Section... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22210 In-line filters (I-C mines). Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of...
30 CFR 57.22210 - In-line filters (I-C mines).
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false In-line filters (I-C mines). 57.22210 Section... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22210 In-line filters (I-C mines). Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of...
30 CFR 57.22210 - In-line filters (I-C mines).
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false In-line filters (I-C mines). 57.22210 Section... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22210 In-line filters (I-C mines). Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of...
In the natural gas industry, transmission pipeline operators use internal combustion (IC) gas-fired engines to provide the mechanical energy needed to drive pipeline gas compressors. As such, owners and operators of compressor stations are interested in the performance of these e...
GENERAL VIEW LOOKING NORTHWEST AT THE SATURN V STATIC TEST ...
GENERAL VIEW LOOKING NORTHWEST AT THE SATURN V STATIC TEST FACILITY. THIS TEST FACILITY WAS DESIGNED TO RESIST THE 12 MILLION POUNDES OF THRUST GENERATED BY THE THE SATURN V FIRST STAGE ENGINE CLUSTER. - Marshall Space Flight Center, Saturn V S-IC Static Test Facility, West Test Area, Huntsville, Madison County, AL
CFD and Thermo Mechanical Analysis on Effect of Curved vs Step Surface in IC Engine Cylinder Head
NASA Astrophysics Data System (ADS)
Balaji, S.; Ganesh, N.; Kumarasamy, A.
2017-05-01
Current research in IC engines mainly focus on various methods to achieve higher efficiency and high specific power. As a single design parameter, combustion chamber peak spring pressure has increased more than before. Apart from the structural aspects of withstanding these loads, designer faces challenges of resolving thermal aspects of cylinder head. Methods to enhance the heat transfer without compromising load withstanding capability are being constantly explored. Conventional cylinder heads have got sat inner surface. In this paper we have suggested a modification in inner surface to enhance the heat transfer capability. To increase the heat transfer rate, inner same deck surface is configured as a curved and stepped surface instead of sat. We have reported the effectiveness of extend of curvature in the inner same deck surface in a different technical paper. Here, we are making a direct comparison between stepped and curved surface only. From this analysis it has been observed that curved surface reduces the ame deck temperature considerably without compromising the structural strength factors compared to step and sat surface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jatana, Gurneesh; Geckler, Sam; Koeberlein, David
We designed and developed a 4-probe multiplexed multi-species absorption spectroscopy sensor system for gas property measurements on the intake side of commercial multi-cylinder internal-combustion (I.C.) engines; the resulting cycle- and cylinder-resolved concentration, temperature and pressure measurements are applicable for assessing spatial and temporal variations in the recirculated exhaust gas (EGR) distribution at various locations along the intake gas path, which in turn is relevant to assessing cylinder charge uniformity, control strategies, and CFD models. Furthermore, the diagnostic is based on absorption spectroscopy and includes an H 2O absorption system (utilizing a 1.39 m distributed feedback (DFB) diode laser) for measuringmore » gas temperature, pressure, and H 2O concentration, and a CO 2 absorption system (utilizing a 2.7 m DFB laser) for measuring CO 2 concentration. The various lasers, optical components and detectors were housed in an instrument box, and the 1.39- m and 2.7- m lasers were guided to and from the engine-mounted probes via optical fibers and hollow waveguides, respectively. The 5kHz measurement bandwidth allows for near-crank angle resolved measurements, with a resolution of 1.2 crank angle degrees at 1000 RPM. Our use of compact stainless steel measurement probes enables simultaneous multi-point measurements at various locations on the engine with minimal changes to the base engine hardware; in addition to resolving large-scale spatial variations via simultaneous multi-probe measurements, local spatial gradients can be resolved by translating individual probes. Along with details of various sensor design features and performance, we also demonstrate validation of the spectral parameters of the associated CO 2 absorption transitions using both a multi-pass heated cell and the sensor probes.« less
A Physics-Based Approach for Power Integrity in Multi-Layered PCBs
NASA Astrophysics Data System (ADS)
Zhao, Biyao
Developing a power distribution network (PDN) for ASICs and ICs to achieve the low-voltage ripple specifications for current digital designs is challenging with the high-speed and low-voltage ICs. Present methods are typically guided by best engineering practices for low impedance looking into the PDN from the IC. A pre-layout design methodology for power integrity in multi-layered PCB PDN geometry is proposed in the thesis. The PCB PDN geometry is segmented into four parts and every part is modelled using different methods based on the geometry details of the part. Physics-based circuit models are built for every part and the four parts are re-assembled into one model. The influence of geometry details is clearly revealed in this methodology. Based on the physics-based circuit mode, the procedures of using the pre-layout design methodology as a guideline during the PDN design is illustrated. Some common used geometries are used to build design space, and the design curves with the geometry details are provided to be a look up library for engineering use. The pre-layout methodology is based on the resonant cavity model of parallel planes for the cavity structures, and parallel-plane PEEC (PPP) for the irregular shaped plane inductance, and PEEC for the decoupling capacitor connection above the top most or bottom most power-return planes. PCB PDN is analyzed based on the input impedance looking into the PCB from the IC. The pre-layout design methodology can be used to obtain the best possible PCB PDN design. With the switching current profile, the target impedance can be selected to evaluate the PDN performance, and the frequency domain PDN input impedance can be used to obtain the voltage ripple in the time domain to give intuitive insight of the geometry impact on the voltage ripple.
Characterization of indigenous chicken production systems in Kenya.
Okeno, Tobias O; Kahi, Alexander K; Peters, Kurt J
2012-03-01
Indigenous chicken (IC) and their production systems were characterized to understand how the whole system operates for purposes of identifying threats and opportunities for holistic improvement. A survey involving 594 households was conducted in six counties with the highest population of IC in Kenya using structured questionnaires. Data on IC farmers' management practices were collected and analysed and inbreeding levels calculated based on the effective population size. Indigenous chicken were ranked highest as a source of livestock income by households in medium- to high-potential agricultural areas, but trailed goats in arid and semi-arid areas. The production system practised was mainly low-input and small-scale free range, with mean flock size of 22.40 chickens per household. The mean effective population size was 16.02, translating to high levels of inbreeding (3.12%). Provision for food and cash income were the main reasons for raising IC, whilst high mortality due to diseases, poor nutrition, housing and marketing channels were the major constraints faced by farmers. Management strategies targeting improved healthcare, nutrition and housing require urgent mitigation measures, whilst rural access road network needs to be developed for ease of market accessibility. Sustainable genetic improvement programmes that account for farmers' multiple objectives, market requirements and the production circumstances should be developed for a full realization of IC productivity.
Section 107 Detailed Project Report. Fort Gaines Channel (Government Cut) at Dauphin Island, Alabama
1990-03-01
Engineer District, Mobile AREA &WORK UNIT NUMBERS Plan Dev. Sec., Planning Div., (CESAM-PD-FP)- P. 0. Box 2-288, Mobi,L.3.a6628-OO.....,__ 11I...C’ONTAOLLING OFFICE NAME AND ADDRESS M 2 REPORT DATE US. Army Engineer District, Mobile March 1990 Pian Development Sec., Plan. Div., (CESAM-PD-FP) 13 NUMBER...OF PAGES P- 0. Box 2288, Mobile , AL 36628-0001 162 t4. MONITORING AGENCY NAME & ADORESS(11 different from Controlling Office) 15. SECURITY CLASS. (ol
Shin, Jung-Youn; Jeong, Jee-Heon; Han, Jin; Bhang, Suk Ho; Jeong, Gun-Jae; Haque, Muhammad R.; Al-Hilal, Taslim A.; Noh, Myungkyung
2015-01-01
Although islet transplantation has been suggested as an alternative therapy for type 1 diabetes, there are efficiency concerns that are attributed to poor engraftment of transplanted islets. Hypoxic condition and delayed vasculogenesis induce necrosis and apoptosis of the transplanted islets. To overcome these limitations in islet transplantation, heterospheroids (HSs), which consist of rat islet cells (ICs) and human bone marrow-derived mesenchymal stem cells (hMSCs), were transplanted to the kidney and liver. The HSs cultured under the hypoxic condition system exhibited a significant increase in antiapoptotic gene expression in ICs. hMSCs in the HSs secreted angiogenic and antiapoptotic proteins. With the HS system, ICs and hMSCs were successfully located in the same area of the liver after transplantation of HSs through the portal vein, whereas the transplantation of islets and the dissociated hMSCs did not result in localization of transplanted ICs and hMSCs in the same area. HS transplantation resulted in an increase in angiogenesis at the transplantation area and a decrease in the apoptosis of transplanted ICs after transplantation into the kidney subcapsule compared with transplantation of islet cell clusters (ICCs). Insulin production levels of ICs were higher in the HS transplantation group compared with the ICC transplantation group. The HS system may be a more efficient transplantation method than the conventional methods for the treatment of type 1 diabetes. PMID:25344077
Cloutier, Nathalie; Allaeys, Isabelle; Marcoux, Genevieve; Machlus, Kellie R; Mailhot, Benoit; Zufferey, Anne; Levesque, Tania; Becker, Yann; Tessandier, Nicolas; Melki, Imene; Zhi, Huiying; Poirier, Guy; Rondina, Matthew T; Italiano, Joseph E; Flamand, Louis; McKenzie, Steven E; Cote, Francine; Nieswandt, Bernhard; Khan, Waliul I; Flick, Matthew J; Newman, Peter J; Lacroix, Steve; Fortin, Paul R; Boilard, Eric
2018-02-13
There is a growing appreciation for the contribution of platelets to immunity; however, our knowledge mostly relies on platelet functions associated with vascular injury and the prevention of bleeding. Circulating immune complexes (ICs) contribute to both chronic and acute inflammation in a multitude of clinical conditions. Herein, we scrutinized platelet responses to systemic ICs in the absence of tissue and endothelial wall injury. Platelet activation by circulating ICs through a mechanism requiring expression of platelet Fcγ receptor IIA resulted in the induction of systemic shock. IC-driven shock was dependent on release of serotonin from platelet-dense granules secondary to platelet outside-in signaling by αIIbβ3 and its ligand fibrinogen. While activated platelets sequestered in the lungs and leaky vasculature of the blood-brain barrier, platelets also sequestered in the absence of shock in mice lacking peripheral serotonin. Unexpectedly, platelets returned to the blood circulation with emptied granules and were thereby ineffective at promoting subsequent systemic shock, although they still underwent sequestration. We propose that in response to circulating ICs, platelets are a crucial mediator of the inflammatory response highly relevant to sepsis, viremia, and anaphylaxis. In addition, platelets recirculate after degranulation and sequestration, demonstrating that in adaptive immunity implicating antibody responses, activated platelets are longer lived than anticipated and may explain platelet count fluctuations in IC-driven diseases.
Development of high-performance printed organic field-effect transistors and integrated circuits.
Xu, Yong; Liu, Chuan; Khim, Dongyoon; Noh, Yong-Young
2015-10-28
Organic electronics is regarded as an important branch of future microelectronics especially suited for large-area, flexible, transparent, and green devices, with their low cost being a key benefit. Organic field-effect transistors (OFETs), the primary building blocks of numerous expected applications, have been intensively studied, and considerable progress has recently been made. However, there are still a number of challenges to the realization of high-performance OFETs and integrated circuits (ICs) using printing technologies. Therefore, in this perspective article, we investigate the main issues concerning developing high-performance printed OFETs and ICs and seek strategies for further improvement. Unlike many other studies in the literature that deal with organic semiconductors (OSCs), printing technology, and device physics, our study commences with a detailed examination of OFET performance parameters (e.g., carrier mobility, threshold voltage, and contact resistance) by which the related challenges and potential solutions to performance development are inspected. While keeping this complete understanding of device performance in mind, we check the printed OFETs' components one by one and explore the possibility of performance improvement regarding device physics, material engineering, processing procedure, and printing technology. Finally, we analyze the performance of various organic ICs and discuss ways to optimize OFET characteristics and thus develop high-performance printed ICs for broad practical applications.
Kimura, Richard H; Cheng, Zhen; Gambhir, Sanjiv Sam; Cochran, Jennifer R
2009-01-01
There is a critical need for molecular imaging agents to detect cell surface integrin receptors that are present in human cancers. Previously, we used directed evolution to engineer knottin peptides that bind with low nM affinity to integrin receptors that are overexpressed on the surface of tumor cells and the tumor neovasculature. To evaluate these peptides as molecular imaging agents, we site-specifically conjugated Cy5.5 or 64Cu-DOTA to their N-termini, and used optical and positron emission tomography (PET) imaging to measure their uptake and biodistribution in U87MG glioblastoma murine xenograft models. Near-infrared fluorescence and microPET imaging both demonstrated that integrin binding affinity plays a strong role in the tumor uptake of knottin peptides. Tumor uptake at 1 h post injection for two high affinity (IC50 ∼20 nM) 64Cu-DOTA-conjugated knottin peptides was 4.47 ± 1.21 and 4.56 ± 0.64 % injected dose/gram (%ID/g), compared to a low affinity knottin peptide (IC50 ∼0.4 μM; 1.48 ± 0.53 %ID/g) and c(RGDyK) (IC50 ∼1 μM; 2.32 ± 0.55 %ID/g), a low affinity cyclic pentapeptide under clinical development. Furthermore, 64Cu-DOTA-conjugated knottin peptides generated lower levels of non-specific liver uptake (∼2 %ID/g) compared to c(RGDyK) (∼4 %ID/g) 1 h post injection. MicroPET imaging results were confirmed by in vivo biodistribution studies. 64Cu-DOTA-conjugated knottin peptides were stable in mouse serum, and in vivo metabolite analysis showed minimal degradation in the blood or tumor upon injection. Thus, engineered integrin-binding knottin peptides show great potential as clinical diagnostics for a variety of cancers. PMID:19276378
Duzel, Antonija; Vlainic, Josipa; Antunovic, Marko; Malekinusic, Dominik; Vrdoljak, Borna; Samara, Mariam; Gojkovic, Slaven; Krezic, Ivan; Vidovic, Tinka; Bilic, Zdenko; Knezevic, Mario; Sever, Marko; Lojo, Nermin; Kokot, Antonio; Kolovrat, Marijan; Drmic, Domagoj; Vukojevic, Jaksa; Kralj, Tamara; Kasnik, Katarina; Siroglavic, Marko; Seiwerth, Sven; Sikiric, Predrag
2017-12-28
To provide new insights in treatment of colitis and ischemia and reperfusion in rats using stable gastric pentadecapeptide BPC 157. Medication [BPC 157, L-NAME, L-arginine (alone/combined), saline] was bath at the blood deprived colon segment. During reperfusion, medication was BPC 157 or saline. We recorded (USB microscope camera) vessel presentation through next 15 min of ischemic colitis (IC-rats) or reperfusion (removed ligations) (IC + RL-rats); oxidative stress as MDA (increased (IC- and IC + RL-rats)) and NO levels (decreased (IC-rats); increased (IC + RL-rats)) in colon tissue. IC + OB-rats [IC-rats had additional colon obstruction (OB)] for 3 d (IC + OB-rats), then received BPC 157 bath. Commonly, in colon segment (25 mm, 2 ligations on left colic artery and vein, 3 arcade vessels within ligated segment), in IC-, IC + RL-, IC + OB-rats, BPC 157 (10 μg/kg) bath (1 mL/rat) increased vessel presentation, inside/outside arcade interconnections quickly reappeared, mucosal folds were preserved and the pale areas were small and markedly reduced. BPC 157 counteracted worsening effects induced by L-NAME (5 mg) and L-arginine (100 mg). MDA- and NO-levels were normal in BPC 157 treated IC-rats and IC + RL-rats. In addition, on day 10, BPC 157-treated IC + OB-rats presented almost completely spared mucosa with very small pale areas and no gross mucosal defects; the treated colon segment was of normal diameter, and only small adhesions were present. BPC 157 is a fundamental treatment that quickly restores blood supply to the ischemically injured area and rapidly activates collaterals. This effect involves the NO system.
Duzel, Antonija; Vlainic, Josipa; Antunovic, Marko; Malekinusic, Dominik; Vrdoljak, Borna; Samara, Mariam; Gojkovic, Slaven; Krezic, Ivan; Vidovic, Tinka; Bilic, Zdenko; Knezevic, Mario; Sever, Marko; Lojo, Nermin; Kokot, Antonio; Kolovrat, Marijan; Drmic, Domagoj; Vukojevic, Jaksa; Kralj, Tamara; Kasnik, Katarina; Siroglavic, Marko; Seiwerth, Sven; Sikiric, Predrag
2017-01-01
AIM To provide new insights in treatment of colitis and ischemia and reperfusion in rats using stable gastric pentadecapeptide BPC 157. METHODS Medication [BPC 157, L-NAME, L-arginine (alone/combined), saline] was bath at the blood deprived colon segment. During reperfusion, medication was BPC 157 or saline. We recorded (USB microscope camera) vessel presentation through next 15 min of ischemic colitis (IC-rats) or reperfusion (removed ligations) (IC + RL-rats); oxidative stress as MDA (increased (IC- and IC + RL-rats)) and NO levels (decreased (IC-rats); increased (IC + RL-rats)) in colon tissue. IC + OB-rats [IC-rats had additional colon obstruction (OB)] for 3 d (IC + OB-rats), then received BPC 157 bath. RESULTS Commonly, in colon segment (25 mm, 2 ligations on left colic artery and vein, 3 arcade vessels within ligated segment), in IC-, IC + RL-, IC + OB-rats, BPC 157 (10 μg/kg) bath (1 mL/rat) increased vessel presentation, inside/outside arcade interconnections quickly reappeared, mucosal folds were preserved and the pale areas were small and markedly reduced. BPC 157 counteracted worsening effects induced by L-NAME (5 mg) and L-arginine (100 mg). MDA- and NO-levels were normal in BPC 157 treated IC-rats and IC + RL-rats. In addition, on day 10, BPC 157-treated IC + OB-rats presented almost completely spared mucosa with very small pale areas and no gross mucosal defects; the treated colon segment was of normal diameter, and only small adhesions were present. CONCLUSION BPC 157 is a fundamental treatment that quickly restores blood supply to the ischemically injured area and rapidly activates collaterals. This effect involves the NO system. PMID:29358856
Kamauu, Aaron W C; DuVall, Scott L; Robison, Reid J; Liimatta, Andrew P; Wiggins, Richard H; Avrin, David E
2006-01-01
Although digital teaching files are important to radiology education, there are no current satisfactory solutions for export of Digital Imaging and Communications in Medicine (DICOM) images from picture archiving and communication systems (PACS) in desktop publishing format. A vendor-neutral digital teaching file, the Radiology Interesting Case Server (RadICS), offers an efficient tool for harvesting interesting cases from PACS without requiring modifications of the PACS configurations. Radiologists push imaging studies from PACS to RadICS via the standard DICOM Send process, and the RadICS server automatically converts the DICOM images into the Joint Photographic Experts Group format, a common desktop publishing format. They can then select key images and create an interesting case series at the PACS workstation. RadICS was tested successfully against multiple unmodified commercial PACS. Using RadICS, radiologists are able to harvest and author interesting cases at the point of clinical interpretation with minimal disruption in clinical work flow. RSNA, 2006
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-17
... Corporation Including Express Employment Professionals. 74,111 Alstom Transportation, Hornell, NY May 14, 2009... Serv., Server Systems, IC1, Storage, Backup. 74,316A International Business Cambridge, MA......... June 10, 2009. Machines (IBM), Global Tech Serv., Server Systems, IC1, Storage, Backup. 74,316B...
DOT National Transportation Integrated Search
2017-06-13
In recent years, there has been an increased focus on Traffic Incident Management (TIM) and : incorporation of the Incident Command System (ICS) to reduce traffic congestion on the nation's : Interstates. In fact, studies show that for every minute a...
Studies of new media radiation induced laser. Final Report, 1 February 1979-30 April 1984
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, K.S.; Shiu, Y.J.; Raju, S.R.
Various lasants were investigated especially, 2-iodohepafluoropropane (i-C3F7I) for the direct solar pumped lasers. Optical pumping of iodine laser was achieved using a small flashlamp. Using i-C3F7I as a laser gain medium, threshold inversion density, small signal gain, and laser performance at the elevated temperature were measured. The experimental results and analysis are presented. The iodine laser kinetics of the C3F7I and IBr system were numerically simulated. The concept of a direct solar-pumped laser amplifier using (i-C3F7I) as the laser material was evaluated and several kinetic coefficients for i-C3F7I laser system were reexamined. The results are discussed.
Fog-computing concept usage as means to enhance information and control system reliability
NASA Astrophysics Data System (ADS)
Melnik, E. V.; Klimenko, A. B.; Ivanov, D. Ya
2018-05-01
This paper focuses on the reliability issue of information and control systems (ICS). The authors propose using the elements of the fog-computing concept to enhance the reliability function. The key idea of fog-computing is to shift computations to the fog-layer of the network, and thus to decrease the workload of the communication environment and data processing components. As for ICS, workload also can be distributed among sensors, actuators and network infrastructure facilities near the sources of data. The authors simulated typical workload distribution situations for the “traditional” ICS architecture and for the one with fogcomputing concept elements usage. The paper contains some models, selected simulation results and conclusion about the prospects of the fog-computing as a means to enhance ICS reliability.
The Second Stage of a Saturn V Ready For Test
NASA Technical Reports Server (NTRS)
1970-01-01
This Saturn V S-II (second) stage is being lifted into position for a test at the Vehicle Assembly Building at the Kennedy Space Center. When the Saturn V booster stage (S-IC) burned out and dropped away, power for the Saturn was provided by the 82-foot-long and 33-foot-diameter S-II stage. Developed by the Space Division of North American Aviation under the direction of the Marshall Space Flight Center, the stage utilized five J-2 engines, each producing 200,000 pounds of thrust. The engines used liquid oxygen and liquid hydrogen as propellants. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.
Accelerating functional verification of an integrated circuit
Deindl, Michael; Ruedinger, Jeffrey Joseph; Zoellin, Christian G.
2015-10-27
Illustrative embodiments include a method, system, and computer program product for accelerating functional verification in simulation testing of an integrated circuit (IC). Using a processor and a memory, a serial operation is replaced with a direct register access operation, wherein the serial operation is configured to perform bit shifting operation using a register in a simulation of the IC. The serial operation is blocked from manipulating the register in the simulation of the IC. Using the register in the simulation of the IC, the direct register access operation is performed in place of the serial operation.
NASA Astrophysics Data System (ADS)
Xu, Shengzhi; Chu, Ian; Zhao, Gengshen; Wang, Qingzhang
2008-03-01
When proceed photovoltaic power system design, engineer needs prepared model of PV cells to evaluate system response, capability performance, and stability, the DC model is not enough, but an accuracy AC model plays a big role. This paper talks first about the AC model of PV cells, and DC model is also introduced in simple. There is a PV controller example explaining the steps to do system simulation in this paper. Two equivalent circuit models are implemented with mixed-signal language verilog-a, one hardware language easy to use and having good speed and high accuracy. Both of two models include solar cell arrays, one buck switched mode DC-DC converter, and the maximum power point tracking algorithm. The difference between them is that Solar cell in one of two models is with ac small signal parameter, another is without. The simulation result is given in comparison. This paper's work shows that ac parameter plays large role in switch-mode PV power system, especially when the switch frequency is higher than 100kHz.
Investigation of turbocharger compressor surge inception by means of an acoustic two-port model
NASA Astrophysics Data System (ADS)
Kabral, R.; Åbom, M.
2018-01-01
The use of centrifugal compressors have increased tremendously in the last decade being implemented in the modern IC engine design as a key component. However, an efficient implementation is restricted by the compression system surge phenomenon. The focus in the investigation of surge inception have mainly been on the aerodynamic field while neglecting the acoustic field. In the present work a new method based on the full acoustic 2-port model is proposed for investigation of centrifugal compressor stall and surge inception. Essentially, the compressor is acoustically decoupled from the compression system, hence enabling the determination of sound generation and the quantification of internal aero-acoustic coupling effects, both independently of the connected pipe system. These frequency dependent quantities are indicating if the compressor is prone to self-sustained oscillations in case of positive feedback when installed in a system. The method is demonstrated on experimentally determined 2-port data of an automotive turbocharger centrifugal compressor under a variety of realistic operating conditions.
Trees Containing Built-In Pulping Catalysts - Final Report - 08/18/1997 - 08/18/2000
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pullman, G.; Dimmel, D.; Peter, G.
2000-08-18
Several hardwood and softwood trees were analyzed for the presence of anthraquinone-type molecules. Low levels of anthraquinone (AQ) and anthrone components were detected using gas chromatography-mass spectroscopy and sensitive selected-ion monitoring techniques. Ten out of seventeen hardwood samples examined contained AQ-type components; however, the levels were typically below {approximately}6 ppm. No AQs were observed in the few softwood samples that were examined. The AQs were more concentrated in the heartwood of teak than in the sapwood. The delignification of pine was enhanced by the addition of teak chips ({approximately}0.7% AQ-equivalence content) to the cook, suggesting that endogenous AQs can bemore » released from wood during pulping and can catalyze delignification reactions. Eastern cottonwood contained AQ, methyl AQ, and dimethyl AQ, all useful for wood pulping. This is the first time unsubstituted AQ has been observed in wood extracts. Due to the presence of these pulping catalysts, rapid growth rates in plantation settings, and the ease of genetic transformation, eastern cottonwood is a suitable candidate for genetic engineering studies to enhance AQ content. To achieve effective catalytic pulping activity, poplar and cottonwood, respectively, require {approximately}100 and 1000 times more for pulping catalysts. A strategy to increase AQ concentration in natural wood was developed and is currently being tested. This strategy involves ''turning up'' isochorismate synthase (ICS) through genetic engineering. Isochorismate synthase is the first enzyme in the AQ pathway branching from the shikimic acid pathway. In general, the level of enzyme activity at the first branch point or committed step controls the flux through a biosynthetic pathway. To test if the level of ICS regulates AQ biosynthesis in plant tissues, we proposed to over-express this synthase in plant cells. A partial cDNA encoding a putative ICS was available from the random cDNA sequencing project carried out with Arabidopsis thaliana. We used this putative plant ICS gene fragment to isolate and sequence a full-length ICS cDNA from Arabidopsis thaliana. The putative full-length cDNA encodes for a 569 amino acid protein of {approximately}62kDa. This sequence represents the first full-length ICS cDNA isolated from a plant. When inserted into E. coli, our isolated cDNA over-expressed ICS protein in the insoluble inclusion bodies. A plant expression vector containing the ICS cDNA, NP II for selection on the antibiotic kanamycin, and duplicated 35S-cauliflower mosaic virus promoter were inserted into Agrobacterium tumefaciens strain GV3101. Transformation experiments for insertion of these foreign genes into Populus deltoides 'C175' resulted in eight lines able to regenerate shoots and grow roots in the presence of kanamycin. Plants from these eight lines have acclimated to growth in sterile soil and will be moved to a greenhouse environment in spring 2001. Non rooted shoots from each line are currently being multiplied by shoot culture. When enough shoot tissue and/or greenhouse plant stem tissue is available, AQ analysis will be done and compared with non transformed control tissue.« less
1964-10-01
The components of the Saturn V booster (S-IC stage) fuel tank are shown in this photograph. The liquid oxygen tank bulkhead on the left and both halves of the fuel tank were in the Marshall Space Flight Center (MSFC) Manufacturing Engineering Laboratory, building 4707. These components were used at MSFC in structural testing to prove that they could withstand the forces to which they were subjected in flight. Each S-IC stage has two tanks, one for kerosene and one for liquid oxygen, made from such components as these. Thirty-three feet in diameter, they hold a total of 4,400,000 pounds of fuel. Although this tankage was assembled at MSFC, the elements were made by the Boeing Company at Wichita and the Michoud Operations at New Orleans.
Seemayer, N H; Hadnagy, W; Tomingas, R
1987-03-01
Extract of particulate matter (EPM) of gasoline engine exhaust induced only a slight loss of cell viability of mouse macrophages (line IC-21) in vitro, while a strong dose-dependent reduction of plating efficiency of human cell line A-549 and of Syrian hamster line 14-1b occurred. Cytological investigations of exposed macrophages of line IC-21 revealed an increase in the mitotic index from 1.5% of control values up to 14.6% at the highest tested concentration of EPM. Mitotic arrest is based almost exclusively on C-type mitoses occurring dose-dependently in the presence of EPM. Results indicate disturbances of the spindle apparatus in the presence of EPM.
1963-08-12
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built to the east was a newly constructed Pump House. Its function was to provide water to the stand to prevent melting damage during testing. The water was sprayed through small holes in the stand’s 1900 ton flame deflector at the rate of 320,000 gallons per minute. In this photo, taken August 12, 1963, the S-IC stand has received some of its internal components. Directly in the center is the framework that houses the flame deflector. The F-1 test stand, designed and built to test a single F-1 engine, can be seen on the left side of the photo.
40 CFR 52.1070 - Identification of plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Burning Equipment 11/11/02 8/6/03, 68 FR 46487 (c)(181). 26.11.06.06 Volatile Organic Compounds 9/22/97 5... a State effective date of 5/8/95 [(c)(182)(i)(C)]. 26.11.06.10 Refuse Burning Prohibited in Certain....11.09Control of Fuel Burning Equipment, Stationary Internal Combustion Engines, and Certain Fuel...
Pasma, Jantsje H.; Assländer, Lorenz; van Kordelaar, Joost; de Kam, Digna; Mergner, Thomas; Schouten, Alfred C.
2018-01-01
The Independent Channel (IC) model is a commonly used linear balance control model in the frequency domain to analyze human balance control using system identification and parameter estimation. The IC model is a rudimentary and noise-free description of balance behavior in the frequency domain, where a stable model representation is not guaranteed. In this study, we conducted firstly time-domain simulations with added noise, and secondly robot experiments by implementing the IC model in a real-world robot (PostuRob II) to test the validity and stability of the model in the time domain and for real world situations. Balance behavior of seven healthy participants was measured during upright stance by applying pseudorandom continuous support surface rotations. System identification and parameter estimation were used to describe the balance behavior with the IC model in the frequency domain. The IC model with the estimated parameters from human experiments was implemented in Simulink for computer simulations including noise in the time domain and robot experiments using the humanoid robot PostuRob II. Again, system identification and parameter estimation were used to describe the simulated balance behavior. Time series, Frequency Response Functions, and estimated parameters from human experiments, computer simulations, and robot experiments were compared with each other. The computer simulations showed similar balance behavior and estimated control parameters compared to the human experiments, in the time and frequency domain. Also, the IC model was able to control the humanoid robot by keeping it upright, but showed small differences compared to the human experiments in the time and frequency domain, especially at high frequencies. We conclude that the IC model, a descriptive model in the frequency domain, can imitate human balance behavior also in the time domain, both in computer simulations with added noise and real world situations with a humanoid robot. This provides further evidence that the IC model is a valid description of human balance control. PMID:29615886
Pasma, Jantsje H; Assländer, Lorenz; van Kordelaar, Joost; de Kam, Digna; Mergner, Thomas; Schouten, Alfred C
2018-01-01
The Independent Channel (IC) model is a commonly used linear balance control model in the frequency domain to analyze human balance control using system identification and parameter estimation. The IC model is a rudimentary and noise-free description of balance behavior in the frequency domain, where a stable model representation is not guaranteed. In this study, we conducted firstly time-domain simulations with added noise, and secondly robot experiments by implementing the IC model in a real-world robot (PostuRob II) to test the validity and stability of the model in the time domain and for real world situations. Balance behavior of seven healthy participants was measured during upright stance by applying pseudorandom continuous support surface rotations. System identification and parameter estimation were used to describe the balance behavior with the IC model in the frequency domain. The IC model with the estimated parameters from human experiments was implemented in Simulink for computer simulations including noise in the time domain and robot experiments using the humanoid robot PostuRob II. Again, system identification and parameter estimation were used to describe the simulated balance behavior. Time series, Frequency Response Functions, and estimated parameters from human experiments, computer simulations, and robot experiments were compared with each other. The computer simulations showed similar balance behavior and estimated control parameters compared to the human experiments, in the time and frequency domain. Also, the IC model was able to control the humanoid robot by keeping it upright, but showed small differences compared to the human experiments in the time and frequency domain, especially at high frequencies. We conclude that the IC model, a descriptive model in the frequency domain, can imitate human balance behavior also in the time domain, both in computer simulations with added noise and real world situations with a humanoid robot. This provides further evidence that the IC model is a valid description of human balance control.
Araya, Romina E.; Jury, Jennifer; Bondar, Constanza
2014-01-01
Systemic administration of polyinosinic:polycytidylic acid (poly I:C), mimics virally-induced activation of TLR3 signalling causing acute small intestine damage, but whether and how mucosal administration of poly I:C causes enteropathy is less clear. Our aim was to investigate the inflammatory pathways elicited after intraluminal administration of poly I:C and determine acute and delayed consequences of this locally induced immune activation. Intraluminal poly I:C induced rapid mucosal immune activation in C57BL/6 mice involving IFNβ and the CXCL10/CXCR3 axis, that may drive inflammation towards a Th1 profile. Intraluminal poly I:C also caused enteropathy and gut dysfunction in gliadin-sensitive NOD-DQ8 mice, and this was prolonged by concomitant oral administration of gliadin. Our results indicate that small intestine pathology can be induced in mice by intraluminal administration of poly I:C and that this is exacerbated by subsequent oral delivery of a relevant dietary antigen. PMID:24915573
Araya, Romina E; Jury, Jennifer; Bondar, Constanza; Verdu, Elena F; Chirdo, Fernando G
2014-01-01
Systemic administration of polyinosinic:polycytidylic acid (poly I:C), mimics virally-induced activation of TLR3 signalling causing acute small intestine damage, but whether and how mucosal administration of poly I:C causes enteropathy is less clear. Our aim was to investigate the inflammatory pathways elicited after intraluminal administration of poly I:C and determine acute and delayed consequences of this locally induced immune activation. Intraluminal poly I:C induced rapid mucosal immune activation in C57BL/6 mice involving IFNβ and the CXCL10/CXCR3 axis, that may drive inflammation towards a Th1 profile. Intraluminal poly I:C also caused enteropathy and gut dysfunction in gliadin-sensitive NOD-DQ8 mice, and this was prolonged by concomitant oral administration of gliadin. Our results indicate that small intestine pathology can be induced in mice by intraluminal administration of poly I:C and that this is exacerbated by subsequent oral delivery of a relevant dietary antigen.
Fan, Haitao; Zhang, Ian; Chen, Xuebo; Zhang, Leying; Wang, Huaqing; Fonseca, Anna Da; Manuel, Edwin R.; Diamond, Don J.; Raubitschek, Andrew; Badie, Behnam
2012-01-01
Purpose Recently, we showed that intratumoral delivery of low-dose, immunostimulatory CpG oligodeoxynucleotides conjugated with carbon nanotubes (CNT-CpG) was more effective than free CpG and not only eradicated intracranial (i.c.) gliomas, but also induced antitumor immunity that protected mice from subsequent i.c. or systemic tumor rechallenge. Here, we examined if the same “intracerebral immunotherapy” strategy could be applied to the treatment of metastatic brain tumors. Experimental Design Mice with both i.c. and subcutaneous (s.c.) melanomas were injected intratumorally with CNT-CpG into either location. Antitumor responses were assessed by flow cytometry, bioluminescent imaging, and animal survival. Results When given s.c., CNT-CpG response was mostly local, and it only modestly inhibited the growth of i.c. melanomas. However, i.c. CNT-CpG abrogated the growth of not only brain, but also s.c. tumors. Furthermore, compared to s.c. injections, i.c. CNT-CpG elicited a stronger inflammatory response that resulted in more potent antitumor cytotoxicity and improved in vivo trafficking of effector cells into both i.c. and s.c. tumors. To investigate factors that accounted for these observations, CNT-CpG biodistribution and cellular inflammatory responses were examined in both tumor locations. Intracranial melanomas retained the CNT-CpG particles longer and were infiltrated by TLR-9-positive microglia. In contrast, myeloid-derived suppressive cells were more abundant in s.c. tumors. Although depletion of these cells prior to s.c. CNT-CpG therapy enhanced its cytotoxic responses, antitumor responses to brain melanomas were unchanged. Conclusions These findings suggest that intracerebral CNT-CpG immunotherapy is more effective than systemic therapy in generating antitumor responses that target both brain and systemic melanomas. PMID:22904105
Fan, Haitao; Zhang, Ian; Chen, Xuebo; Zhang, Leying; Wang, Huaqing; Da Fonseca, Anna; Manuel, Edwin R; Diamond, Don J; Raubitschek, Andrew; Badie, Behnam
2012-10-15
Recently, we showed that intratumoral delivery of low-dose, immunostimulatory CpG oligodeoxynucleotides conjugated with carbon nanotubes (CNT-CpG) was more effective than free CpG and not only eradicated intracranial (i.c.) gliomas but also induced antitumor immunity that protected mice from subsequent i.c. or systemic tumor rechallenge. Here, we examined whether the same "intracerebral immunotherapy" strategy could be applied to the treatment of metastatic brain tumors. Mice with both i.c. and s.c. melanomas were injected intratumorally with CNT-CpG into either location. Antitumor responses were assessed by flow cytometry, bioluminescent imaging, and animal survival. When given s.c., CNT-CpG response was mostly local, and it only modestly inhibited the growth of i.c. melanomas. However, i.c. CNT-CpG abrogated the growth of not only brain but also s.c. tumors. Furthermore, compared with s.c. injections, i.c. CNT-CpG elicited a stronger inflammatory response that resulted in more potent antitumor cytotoxicity and improved in vivo trafficking of effector cells into both i.c. and s.c. tumors. To investigate factors that accounted for these observations, CNT-CpG biodistribution and cellular inflammatory responses were examined in both tumor locations. Intracranial melanomas retained the CNT-CpG particles longer and were infiltrated by Toll-like receptor (TLR-9)-positive microglia. In contrast, myeloid-derived suppressive cells were more abundant in s.c. tumors. Although depletion of these cells before s.c. CNT-CpG therapy enhanced its cytotoxic responses, antitumor responses to brain melanomas were unchanged. These findings suggest that intracerebral CNT-CpG immunotherapy is more effective than systemic therapy in generating antitumor responses that target both brain and systemic melanomas. ©2012 AACR
Chae, Sung-Wook; Kim, Young-Sung; Lee, Yong-Moo; Kim, Won-Kyung; Lee, Young-Kyoo; Kim, Su-Hwan
2015-02-01
This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (P<0.001). Within the limitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.
Bertram, Timothy A; Johnson, Peter C; Tawil, Bill J; Van Dyke, Mark; Hellman, Kiki B
2015-10-01
TERMIS-AM Industry Committee (TERMIS-AM/IC), in collaboration with the TERMIS-Europe (EU)/IC, conducted a symposium involving the European Medicines Agency and the U.S. Food and Drug Administration (FDA) toward building an understanding of the rational basis for regulatory decision-making and providing a framework for decisions made during the evaluation of safety and efficacy of TE/RM technologies. This symposium was held in August 2012 during the TERMIS-WC in Vienna, Austria. Emerging from this international initiative by the European Union and the United States, representatives from the respective agencies demonstrated that there are ongoing interagency efforts for developing common national practices toward harmonization of regulatory requirements for the TE/RM products. To extend a broad-based understanding of the role of science in regulatory decision-making, TERMIS-AM/IC, in cooperation with the FDA, organized a symposium at the 2014 TERMIS-AM Annual Meeting, which was held in Washington, DC. This event provided insights from leaders in the FDA and TERMIS on the current status of regulatory approaches for the approved TE/RM products, the use of science in making regulatory decisions, and TE/RM technologies that are in the development pipeline to address unmet medical needs. A far-ranging discussion with FDA representatives, industrialists, physicians, regenerative medicine biologists, and tissue engineers considered the gaps in today's scientific and regulatory understanding of TE/RM technologies. The identified gaps represent significant opportunities to advance TE/RM technologies toward commercialization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-02-01
This poster describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1TM. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
Host-pathogen-interaction reconstituted in 3-dimensional cocultures of mucosa and C. albicans.
Buchs, Romina; Lehner, Bruno; Meuwly, Phillippe; Schnyder, Bruno
2018-06-14
C. albicans frequently causes recurrent intimal infectious disease (ID). This demands the treatment of multiple phases of the infection. The objective of this study was to uncover the host-pathogen-interaction using 2D epithelium cell-barrier and 3D subepithelium tissue cells of human mucosa. The 2D cell cultures assessed C. albicans adhesion. Addition of the anti-fungal drug Fluconazol did not inhibit the adhesion, despite its pathogen growth inhibition (MIC value 0.08μg/mL). A 3D tissue was engineered in multi-transwells by placing human fibroblast cultures on a thick porous scaffold. This contained the yeast placed in the top compartment and prevented passive penetration. After 28h the pathogen transmigrated the barrier and was collected in the bottom compartment. A change in pathogen morphology was observed where hypha formed and grew to be 231μm long after 28h. The hypha was thus long enough to cross the 200μm thick 3D tissue. The 3D infection was inhibited by addition of Fluconazol (0.08μg/mL), confirming that penetration is dependent on pathogen growth. In conclusion, ID was reconstituted step-by-step on 2D epithelium surface and in 3D connective tissue of human mucosa. Fluconazol growth-inhibition of the pathogen C. albicans was confirmed in the 3D tissue. We thus propose that this ID in vitro test is suitable for the identification and characterization of new treatments against C. albicans..
Si light-emitting device in integrated photonic CMOS ICs
NASA Astrophysics Data System (ADS)
Xu, Kaikai; Snyman, Lukas W.; Aharoni, Herzl
2017-07-01
The motivation for integrated Si optoelectronics is the creation of low-cost photonics for mass-market applications. Especially, the growing demand for sensitive biochemical sensors in the environmental control or medicine leads to the development of integrated high resolution sensors. Here CMOS-compatible Si light-emitting device structures are presented for investigating the effect of various depletion layer profiles and defect engineering on the photonic transition in the 1.4-2.8 eV. A novel Si device is proposed to realize both a two-terminal Si-diode light-emitting device and a three-terminal Si gate-controlled diode light-emitting device in the same device structure. In addition to the spectral analysis, differences between two-terminal and three-terminal devices are discussed, showing the light emission efficiency change. The proposed Si optical source may find potential applications in micro-photonic systems and micro-optoelectro-mechanical systems (MOEMS) in CMOS integrated circuitry.
Technical Basis for Evaluating Software-Related Common-Cause Failures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muhlheim, Michael David; Wood, Richard
2016-04-01
The instrumentation and control (I&C) system architecture at a nuclear power plant (NPP) incorporates protections against common-cause failures (CCFs) through the use of diversity and defense-in-depth. Even for well-established analog-based I&C system designs, the potential for CCFs of multiple systems (or redundancies within a system) constitutes a credible threat to defeating the defense-in-depth provisions within the I&C system architectures. The integration of digital technologies into the I&C systems provides many advantages compared to the aging analog systems with respect to reliability, maintenance, operability, and cost effectiveness. However, maintaining the diversity and defense-in-depth for both the hardware and software within themore » digital system is challenging. In fact, the introduction of digital technologies may actually increase the potential for CCF vulnerabilities because of the introduction of undetected systematic faults. These systematic faults are defined as a “design fault located in a software component” and at a high level, are predominately the result of (1) errors in the requirement specification, (2) inadequate provisions to account for design limits (e.g., environmental stress), or (3) technical faults incorporated in the internal system (or architectural) design or implementation. Other technology-neutral CCF concerns include hardware design errors, equipment qualification deficiencies, installation or maintenance errors, instrument loop scaling and setpoint mistakes.« less
Fast time- and frequency-domain finite-element methods for electromagnetic analysis
NASA Astrophysics Data System (ADS)
Lee, Woochan
Fast electromagnetic analysis in time and frequency domain is of critical importance to the design of integrated circuits (IC) and other advanced engineering products and systems. Many IC structures constitute a very large scale problem in modeling and simulation, the size of which also continuously grows with the advancement of the processing technology. This results in numerical problems beyond the reach of existing most powerful computational resources. Different from many other engineering problems, the structure of most ICs is special in the sense that its geometry is of Manhattan type and its dielectrics are layered. Hence, it is important to develop structure-aware algorithms that take advantage of the structure specialties to speed up the computation. In addition, among existing time-domain methods, explicit methods can avoid solving a matrix equation. However, their time step is traditionally restricted by the space step for ensuring the stability of a time-domain simulation. Therefore, making explicit time-domain methods unconditionally stable is important to accelerate the computation. In addition to time-domain methods, frequency-domain methods have suffered from an indefinite system that makes an iterative solution difficult to converge fast. The first contribution of this work is a fast time-domain finite-element algorithm for the analysis and design of very large-scale on-chip circuits. The structure specialty of on-chip circuits such as Manhattan geometry and layered permittivity is preserved in the proposed algorithm. As a result, the large-scale matrix solution encountered in the 3-D circuit analysis is turned into a simple scaling of the solution of a small 1-D matrix, which can be obtained in linear (optimal) complexity with negligible cost. Furthermore, the time step size is not sacrificed, and the total number of time steps to be simulated is also significantly reduced, thus achieving a total cost reduction in CPU time. The second contribution is a new method for making an explicit time-domain finite-element method (TDFEM) unconditionally stable for general electromagnetic analysis. In this method, for a given time step, we find the unstable modes that are the root cause of instability, and deduct them directly from the system matrix resulting from a TDFEM based analysis. As a result, an explicit TDFEM simulation is made stable for an arbitrarily large time step irrespective of the space step. The third contribution is a new method for full-wave applications from low to very high frequencies in a TDFEM based on matrix exponential. In this method, we directly deduct the eigenmodes having large eigenvalues from the system matrix, thus achieving a significantly increased time step in the matrix exponential based TDFEM. The fourth contribution is a new method for transforming the indefinite system matrix of a frequency-domain FEM to a symmetric positive definite one. We deduct non-positive definite component directly from the system matrix resulting from a frequency-domain FEM-based analysis. The resulting new representation of the finite-element operator ensures an iterative solution to converge in a small number of iterations. We then add back the non-positive definite component to synthesize the original solution with negligible cost.
Assessment of Durable SiC JFET Technology for +600 C to -125 C Integrated Circuit Operation
NASA Technical Reports Server (NTRS)
Neudeck, P. G.; Krasowski, M. J.; Prokop, N. F.
2011-01-01
Electrical characteristics and circuit design considerations for prototype 6H-SiC JFET integrated circuits (ICs) operating over the broad temperature range of -125 C to +600 C are described. Strategic implementation of circuits with transistors and resistors in the same 6H-SiC n-channel layer enabled ICs with nearly temperature-independent functionality to be achieved. The frequency performance of the circuits declined at temperatures increasingly below or above room temperature, roughly corresponding to the change in 6H-SiC n-channel resistance arising from incomplete carrier ionization at low temperature and decreased electron mobility at high temperature. In addition to very broad temperature functionality, these simple digital and analog demonstration integrated circuits successfully operated with little change in functional characteristics over the course of thousands of hours at 500 C before experiencing interconnect-related failures. With appropriate further development, these initial results establish a new technology foundation for realizing durable 500 C ICs for combustion engine sensing and control, deep-well drilling, and other harsh-environment applications.
Baker-Genaw, Kimberly; Kokas, Maria S; Ahsan, Syed F; Darnley-Fisch, Deborah; Drake, Sean; Goyal, Nikhil; Inamdar, Kedar; Moutzouros, Vasilios; Prabhakar, Deepak; Rolland, Laurie; Sangha, Roopina; Shreve, Maria; Woodward, Ann
2016-07-01
Little is known about residents' performance on the milestones at the institutional level. Our institution formed a work group to explore this using an institutional-level curriculum and residents' evaluation of the milestones. We assessed whether beginner-level milestones for interpersonal and communication skills (ICS) related to observable behaviors in ICS-focused objective structured clinical examinations (OSCEs) for postgraduate year (PGY) 1 residents across specialties. The work group compared ICS subcompetencies across 12 programs to identify common beginner-level physician-patient communication milestones. The selected ICS milestone sets were compared for common language with the ICS-OSCE assessment tool-the Kalamazoo Essential Elements of Communication Checklist-Adapted (KEECC-A). To assess whether OSCE scores related to ICS milestone scores, all PGY-1 residents from programs that were part of Next Accreditation System Phase 1 were identified; their OSCE scores from July 2013 to June 2014 and ICS subcompetency scores from December 2014 were compared. The milestones for 10 specialties and the transitional year had at least 1 ICS subcompetency that related to physician-patient communication. The language of the ICS beginner-level milestones appears similar to behaviors outlined in the KEECC-A. All 60 residents with complete data received at least a beginner-level ICS subcompetency score and at least a satisfactory score on all 3 OSCEs. The ICS-OSCE scores for PGY-1 residents appear to relate to beginner-level milestones for physician-patient communication across multiple specialties.
A proposed holistic approach to on-chip, off-chip, test, and package interconnections
NASA Astrophysics Data System (ADS)
Bartelink, Dirk J.
1998-11-01
The term interconnection has traditionally implied a `robust' connection from a transistor or a group of transistors in an IC to the outside world, usually a PC board. Optimum system utilization is done from outside the IC. As an alternative, this paper addresses `unimpeded' transistor-to-transistor interconnection aimed at reaching the high circuit densities and computational capabilities of neighboring IC's. In this view, interconnections are not made to some human-centric place outside the IC world requiring robustness—except for system input and output connections. This unimpeded interconnect style is currently available only through intra-chip signal traces in `system-on-a-chip' implementations, as exemplified by embedded DRAMs. Because the traditional off-chip penalty in performance and wiring density is so large, a merging of complex process technologies is the only option today. It is suggested that, for system integration to move forward, the traditional robustness requirement inherited from conventional packaging interconnect and IC manufacturing test must be discarded. Traditional system assembly from vendor parts requires robustness under shipping, inspection and assembly. The trend toward systems on a chip signifies willingness by semiconductor companies to design and fabricate whole systems in house, so that `in-house' chip-to-chip assembly is not beyond reach. In this scenario, bare chips never leave the controlled environment of the IC fabricator while the two major contributors to off-chip signal penalty, ESD protection and the need to source a 50-ohm test head, are avoided. With in-house assembly, ESD protection can be eliminated with the precautions already familiar in plasma etching. Test interconnection impacts the fundamentals of IC manufacturing, particularly with clock speeds approaching 1GHz, and cannot be an afterthought. It should be an integral part of the chip-to-chip interconnection bandwidth optimization, because—as we must recognize—test is also performed using IC's. A system interconnection is proposed using multiple chips fabricated with conventional silicon processes, including MEMS technology. The system resembles an MCM that can be joined without committing to final assembly to perform at-speed testing. 50-Ohm test probes never load the circuit; only intended neighboring chips are ever connected. A `back-plane' chip provides the connection layers for both inter- and intra-chip signals and also serves as the probe card, in analogy with membrane probes now used for single-chip testing. Intra-chip connections, which require complicated connections during test that exactly match the product, are then properly made and all waveforms and loading conditions under test will be identical to those of the product. The major benefit is that all front-end chip technologies can be merged—logic, memory, RF, even passives. ESD protection is required only on external system connections. Manufacturing test information will accurately characterize process faults and thus avoid the Known-Good-Die problem that has slowed the arrival of conventional MCM's.
Knapp, Caprice; Madden, Vanessa; Sloyer, Phyllis; Shenkman, Elizabeth
2012-04-01
To assess the effects of an Integrated Care System (ICS) on parent-reported quality of care and satisfaction for Children with Special Health Care Needs (CSHCN). In 2006 Florida reformed its Medicaid program in Broward and Duval counties. Children's Medical Services Network (CMSN) chose to participate in the reform and developed an ICS for CSHCN. The ICS ushered in several changes such as more prior approval requirements and closing of the provider network. Telephone surveys were conducted with CMSN parents whose children reside in the reform counties and parents whose children reside outside of the reform counties in 2006 and 2007 (n = 1,727). Results from multivariate quasi-experimental models show that one component of parent-report quality of care, customer service, increased. Following implementation of the ICS, customer service increased by 0.22 points. After implementation of the ICS, parent-reported quality and satisfaction were generally unaffected. Although significant increases were not seen in the majority of the quality and satisfaction domains, it is nonetheless encouraging that parents did not report negative experiences with the ICS. It is important to present these interim findings so that progress can be monitored and decision-makers can begin to consider if the program should be expanded statewide.
Toxicity evaluation and prediction of toxic chemicals on activated sludge system.
Cai, Bijing; Xie, Li; Yang, Dianhai; Arcangeli, Jean-Pierre
2010-05-15
The gaps of data for evaluating toxicity of new or overloaded organic chemicals on activated sludge system resulted in the requirements for methodology of toxicity estimation. In this study, 24 aromatic chemicals typically existed in the industrial wastewater were selected and classified into three groups of benzenes, phenols and anilines. Their toxicity on activated sludge was then investigated. Two indexes of IC(50-M) and IC(50-S) were determined respectively from the respiration rates of activated sludge with different toxicant concentration at mid-term (24h) and short-term (30min) time intervals. Experimental results showed that the group of benzenes was the most toxic, followed by the groups of phenols and anilines. The values of IC(50-M) of the tested chemicals were higher than those of IC(50-S). In addition, quantitative structure-activity relationships (QSARs) models developed from IC(50-M) were more stable and accurate than those of IC(50-S). The multiple linear models based on molecular descriptors and K(ow) presented better reliability than single linear models based on K(ow). Among these molecular descriptors, E(lumo) was the most important impact factor for evaluation of mid-term toxicity. Copyright (c) 2009 Elsevier B.V. All rights reserved.
Rojko, Jennifer L; Evans, Mark G; Price, Shari A; Han, Bora; Waine, Gary; DeWitte, Mark; Haynes, Jill; Freimark, Bruce; Martin, Pauline; Raymond, James T; Evering, Winston; Rebelatto, Marlon C; Schenck, Emanuel; Horvath, Christopher
2014-06-01
Vascular inflammation, infusion reactions, glomerulopathies, and other potentially adverse effects may be observed in laboratory animals, including monkeys, on toxicity studies of therapeutic monoclonal antibodies and recombinant human protein drugs. Histopathologic and immunohistochemical (IHC) evaluation suggests these effects may be mediated by deposition of immune complexes (ICs) containing the drug, endogenous immunoglobulin, and/or complement components in the affected tissues. ICs may be observed in glomerulus, blood vessels, synovium, lung, liver, skin, eye, choroid plexus, or other tissues or bound to neutrophils, monocytes/macrophages, or platelets. IC deposition may activate complement, kinin, and/or coagulation/fibrinolytic pathways and result in a systemic proinflammatory response. IC clearance is biphasic in humans and monkeys (first from plasma to liver and/or spleen, second from liver or spleen). IC deposition/clearance is affected by IC composition, immunomodulation, and/or complement activation. Case studies are presented from toxicity study monkeys or rats and indicate IHC-IC deposition patterns similar to those predicted by experimental studies of IC-mediated reactions to heterologous protein administration to monkeys and other species. The IHC-staining patterns are consistent with findings associated with generalized and localized IC-associated pathology in humans. However, manifestations of immunogenicity in preclinical species are generally not considered predictive to humans. © 2014 by The Author(s).
Interpretive computer simulator for the NASA Standard Spacecraft Computer-2 (NSSC-2)
NASA Technical Reports Server (NTRS)
Smith, R. S.; Noland, M. S.
1979-01-01
An Interpretive Computer Simulator (ICS) for the NASA Standard Spacecraft Computer-II (NSSC-II) was developed as a code verification and testing tool for the Annular Suspension and Pointing System (ASPS) project. The simulator is written in the higher level language PASCAL and implented on the CDC CYBER series computer system. It is supported by a metal assembler, a linkage loader for the NSSC-II, and a utility library to meet the application requirements. The architectural design of the NSSC-II is that of an IBM System/360 (S/360) and supports all but four instructions of the S/360 standard instruction set. The structural design of the ICS is described with emphasis on the design differences between it and the NSSC-II hardware. The program flow is diagrammed, with the function of each procedure being defined; the instruction implementation is discussed in broad terms; and the instruction timings used in the ICS are listed. An example of the steps required to process an assembly level language program on the ICS is included. The example illustrates the control cards necessary to assemble, load, and execute assembly language code; the sample program to to be executed; the executable load module produced by the loader; and the resulting output produced by the ICS.
α–Intercalated cells defend the urinary system from bacterial infection
Paragas, Neal; Kulkarni, Ritwij; Werth, Max; Schmidt-Ott, Kai M.; Forster, Catherine; Deng, Rong; Zhang, Qingyin; Singer, Eugenia; Klose, Alexander D.; Shen, Tian Huai; Francis, Kevin P.; Ray, Sunetra; Vijayakumar, Soundarapandian; Seward, Samuel; Bovino, Mary E.; Xu, Katherine; Takabe, Yared; Amaral, Fábio E.; Mohan, Sumit; Wax, Rebecca; Corbin, Kaitlyn; Sanna-Cherchi, Simone; Mori, Kiyoshi; Johnson, Lynne; Nickolas, Thomas; D’Agati, Vivette; Lin, Chyuan-Sheng; Qiu, Andong; Al-Awqati, Qais; Ratner, Adam J.; Barasch, Jonathan
2014-01-01
α–Intercalated cells (A-ICs) within the collecting duct of the kidney are critical for acid-base homeostasis. Here, we have shown that A-ICs also serve as both sentinels and effectors in the defense against urinary infections. In a murine urinary tract infection model, A-ICs bound uropathogenic E. coli and responded by acidifying the urine and secreting the bacteriostatic protein lipocalin 2 (LCN2; also known as NGAL). A-IC–dependent LCN2 secretion required TLR4, as mice expressing an LPS-insensitive form of TLR4 expressed reduced levels of LCN2. The presence of LCN2 in urine was both necessary and sufficient to control the urinary tract infection through iron sequestration, even in the harsh condition of urine acidification. In mice lacking A-ICs, both urinary LCN2 and urinary acidification were reduced, and consequently bacterial clearance was limited. Together these results indicate that A-ICs, which are known to regulate acid-base metabolism, are also critical for urinary defense against pathogenic bacteria. They respond to both cystitis and pyelonephritis by delivering bacteriostatic chemical agents to the lower urinary system. PMID:24937428
Selection of NIR H2O absorption transitions for in-cylinder measurement of temperature in IC engines
NASA Astrophysics Data System (ADS)
Zhou, Xin; Liu, Xiang; Jeffries, Jay B.; Hanson, Ronald K.
2005-12-01
The water vapour spectrum in the 1.25-1.65 µm region is systematically analysed to find the best absorption transitions for sensitive measurement of in-cylinder gas temperature over short paths in an internal combustion engine. The strategy to select the optimum wavelength regions and absorption line combinations is developed for the time-varying pressures and temperatures expected during the compression portion of an engine cycle. We have identified 14 transitions of water vapour in this spectral region as promising for this application. From these transitions, 16 potential line pairs were considered for a wavelength-modulated absorption sensor for in-cylinder gas temperature during the compression stroke. Expected performance is modelled for the intake portion of two engine cycles that produce extreme temperature and pressure variations during compression.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-11
... NUCLEAR REGULATORY COMMISSION Advisory Committee on Reactor Safeguards (ACRS); Meeting of the ACRS Subcommittee on Digital I&C Systems The ACRS Subcommittee on Digital Instrumentation & Control (DI&C) Systems will hold a meeting on February 23, 2011, Room T-2B3, 11545 Rockville Pike, Rockville, Maryland. The...
An RFID-based on-lens sensor system for long-term IOP monitoring.
Hsu, Shun-Hsi; Chiou, Jin-Chern; Liao, Yu-Te; Yang, Tzu-Sen; Kuei, Cheng-Kai; Wu, Tsung-Wei; Huang, Yu-Chieh
2015-01-01
In this paper, an RFID-based on-lens sensor system is proposed for noninvasive long-term intraocular pressure monitoring. The proposed sensor IC, fabricated in a 0.18um CMOS process, consists of capacitive sensor readout circuitry, RFID communication circuits, and digital processing units. The sensor IC is integrated with electroplating capacitive sensors and a receiving antenna on the contact lens. The sensor IC can be wirelessly powered, communicate with RFID compatible equipment, and perform IOP measurement using on-lens capacitive sensor continuously from a 2cm distance while the incident power from an RFID reader is 20 dBm. The proposed system is compatible to Gen2 RFID protocol, extending the flexibility and reducing the self-developed firmware efforts.
Low-power analog integrated circuits for wireless ECG acquisition systems.
Tsai, Tsung-Heng; Hong, Jia-Hua; Wang, Liang-Hung; Lee, Shuenn-Yuh
2012-09-01
This paper presents low-power analog ICs for wireless ECG acquisition systems. Considering the power-efficient communication in the body sensor network, the required low-power analog ICs are developed for a healthcare system through miniaturization and system integration. To acquire the ECG signal, a low-power analog front-end system, including an ECG signal acquisition board, an on-chip low-pass filter, and an on-chip successive-approximation analog-to-digital converter for portable ECG detection devices is presented. A quadrature CMOS voltage-controlled oscillator and a 2.4 GHz direct-conversion transmitter with a power amplifier and upconversion mixer are also developed to transmit the ECG signal through wireless communication. In the receiver, a 2.4 GHz fully integrated CMOS RF front end with a low-noise amplifier, differential power splitter, and quadrature mixer based on current-reused folded architecture is proposed. The circuits have been implemented to meet the specifications of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the wireless ECG acquisition systems have been fabricated using a 0.18 μm Taiwan Semiconductor Manufacturing Company (TSMC) CMOS standard process. The measured results on the human body reveal that ECG signals can be acquired effectively by the proposed low-power analog front-end ICs.
Millisecond Magnetars as the Central Engine of Gamma-ray Bursts
NASA Astrophysics Data System (ADS)
Wang, L. J.
2017-05-01
The durations of GRBs (gamma-ray bursts) have a bimodal distribution with short-duration GRBs (SGRBs) lasting for less than ˜ 2 s and long-duration GRBs (LGRBs) greater than ˜ 2 s. A large number of observations indicate that LGRBs originate from the collapses of massive stars and are therefore associated with supernovae (SNe). SGRBs, on the other hand, are believed to be the results of binary compact object mergers. Now the study of GRBs has progressed to the stage of identifing the nature of central engines, i.e., black holes or millisecond magnetars. We elaborate the progress in Chapter 1. Numerical simulations support the idea of black holes as the central engine of GRBs since the simulations find the formation of jets by black holes. Some observational features, however, cannot be easily integrated into the black hole model, for example, the X-ray plateau lasting for 100-104 s, the extended emission of SGRBs, X-ray flares, etc. The most concise interpretation for these features is that they are powered by rapidly rotating magnetars. If the central engine is a magnetar, it will dissipate its rotational energy by injecting Poynting flux to the ejecta. Such energy injection will enable an observer outside the jet angle of the SGRB to detect the electromagnetic signals. In Chapter 2, we assume that the Poynting flux from the magnetar will quickly transform into the wind dominated by the ultrarelativistic electron-positron, and then a reverse shock will develop when the wind encounters the ejecta. We find that the recently discovered optical transient PTF11agg can be interpreted as synchrotron emission of reverse shock powered by a millisecond magnetar. In Chapter 3, we consider the absorption of reverse shock emission by the ejecta which is ignored when we study PTF11agg. We also adopt a more realistic dynamics of the blast wave than that adopted in Chapter 2. The ejecta is believed to be pure r-process material which is difficult to study in laboratory. We therefore explore the feasibility to study it by observing the X-ray, UV (ultraviolet), and optical emission obscured by the ejecta. It is found that at early time of the reverse shock emission, the opacity in X-ray band is dominated by elastic scattering of free electrons, the opacity in optical band is dominated by bound-bound transitions, and the opacity in UV band is very likely dominated by bound-free transitions. As a result, the ionization breakout is expected in UV wavelength. In Chapter 4, we consider the effect of inverse Compton (IC) scattering on the electron cooling that was not taken into account in previous 2 chapters. Because the electrons in reverse shock are ultrarelativistic, it is expected that the IC emission is prominent. The effect of IC on synchrotron emission is to reduce its cooling frequency. To utilize the high-energy telescope to probe the birth of millisecond magnetars, we calculate the IC flux from 1 GeV to 100 GeV. It is found that Fermi/LAT (Large Area Telescope) and CTA (Cherenkov Telescope Array) can detect the IC emission powered by a typical magnetar up to ˜ 1 Gpc. In Chapter 5, we discuss some topics that are on hot debate and the perspective for upcoming years.
Visible, Durable, Enforceable Institutional Controls: Weldon Spring Site - A 10-Year Journey - 13190
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uhlmeyer, Terri; Thompson, Randy; Starr, Ken
2013-07-01
The DOE Office of Legacy Management's (LM's) mission is to manage the DOE's post-closure responsibilities and ensure the future protection of human health and the environment. LM has control and custody of legacy land, structures, and facilities and is responsible for maintaining them at levels suitable for their long-term use. This includes all engineered and institutional controls (ICs) designed as another level of assurance to prevent exposure to residual contamination and waste. The development and management of ICs has been, and continues to be, a critical component to the success of LM surveillance and maintenance activities. Many major federal laws,more » Executive Orders, regulations, and various other drivers influence the establishment and use of ICs at LM sites. LM uses a wide range of ICs to appropriately limit access to, or uses of, land, facilities, and other real and personal properties; protect the environment; maintain the physical safety and security of DOE facilities; and prevent or limit inadvertent human and environmental exposure to residual contaminants and other hazards. The ICs at the Weldon Spring, Missouri, Site were developed in close coordination with federal and state regulators. An Explanation of Significant Differences (ESD) was issued in February 2005, which clarified the use restrictions necessary for the remedial actions specified in the Records of Decision for the separate operable units to remain protective over the long-term. The operable units included the Chemical Plant Operable Unit, the Chemical Plant Groundwater Operable Unit, and the Quarry Residuals Operable Unit. The ESD clarified specific requirements for each site area that needed use restrictions and established how DOE would implement, maintain, and monitor the specific requirements. DOE developed the Long-Term Surveillance and Maintenance Plan for the U.S. Department of Energy Weldon Spring, Missouri, Site (LTS and M Plan) that addressed the full scope of the site management activities necessary to ensure that the Weldon Spring Site remains protective over the long-term. The LTS and M Plan is revised periodically to ensure its applicability to changing site, regulatory, or procedural conditions. In addition to addressing such activities as long-term groundwater monitoring and disposal cell maintenance, the LTS and M Plan was developed and issued to ensure that the use restrictions identified in the ESD were properly imposed and maintained. The LTS and M Plan included a detailed IC Implementation Plan, which includes a process for evaluating and identifying specific IC mechanisms that best accomplish the objectives set out in the ESD. Consistent with EPA guidance on selecting ICs, various IC mechanisms were evaluated, including government controls, proprietary controls, enforcement tools, and informational devices. Where appropriate, redundant mechanisms were employed to increase the effectiveness of the ICs. Information in the IC Implementation Plan includes: (1) a discussion of current site conditions (reflecting post-remedial action conditions for the Chemical Plant and Quarry Areas and the risk-basis for why use restrictions are needed); (2) the objectives of, or performance expectations for, the use restrictions; (3) specific ICs already in place and additional mechanisms identified for implementation; (4) a schedule for implementing additional ICs; (5) procedures for maintaining the ICs and for conducting periodic inspections; and (6) general provisions for the implementing ICs for the site. The actual agreements and documentation of the various ICs are included in an appendix of the LTS and M Plan. These documents are also available via the internet from the authorizing agencies (County, Missouri Department of Natural Resources, EPA, etc.) The Weldon Spring Site personnel have been successful in finalizing each of the ICs that were established for the site. The planning, establishment, and implementation of the ICs was a long and detailed process with several lessons-learned that were identified along the way. (authors)« less
A low-power RFID integrated circuits for intelligent healthcare systems.
Lee, Shuenn-Yuh; Wang, Liang-Hung; Fang, Qiang
2010-11-01
This paper presents low-power radio-frequency identification (RFID) technology for intelligent healthcare systems. With attention to power-efficient communication in the body sensor network, RF power transfer was estimated and the required low-power ICs, which are important in the development of a healthcare system with miniaturization and system integration, are discussed based on the RFID platform. To analyze the power transformation, this paper adopts a 915-MHz industrial, scientific, and medical RF with a radiation power of 70 mW to estimate the power loss under the 1-m communication distance between an RFID reader (bioinformation node) and a transponder (biosignal acquisition nodes). The low-power ICs of the transponder will be implemented in the TSMC 0.18-μm CMOS process. The simulation result reveals that the transponder's IC can fit in with the link budget of the UHF RFID system.
Training Extract, AFSC 113X0B, Flight Engineer, Helicopter Qualified.
1982-12-01
TRAINING .................................................................. 1I0 SE. GENERAL rLIGHT RULES A 9 C t | 7. PeRFORM INSPECIIOIS 12 7A... TRAINING .................................................................. lIC 6E. GENERAL FLIGHT RULES A a C...ME"BERS PERFORMING I-A I PROGRAM GENERATED VECTOR IMEMBERS/ NO TYPE VECTOR MEAN - SC DESCRIPTION I TN. SEP J.6 2.J TRAINING EMPHASIS RATINSS I IIOS
Vectors for Treatment of Metastatic Breast Cancer
2005-08-01
from human carcinomas of the breast, ovary and mouse breast cancer. In this study, in vitro cytotoxicity tests were carried out with the replication...injection of dendritic cells engineered to secrete interleukin-12 by recombinant adenovirus in patients with metastatic gastrointestinal carcinomas . J...see Figure IC) in carcinomas of the breast, lung, prostate, ovary, cervix, endometrium, esophagous, stomach and colon is associated with metastasis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vladimir Gorokhovsky
2008-03-31
This report describes significant results from an on-going, collaborative effort to enable the use of inexpensive metallic alloys as interconnects in planar solid oxide fuel cells (SOFCs) through the use of advanced coating technologies. Arcomac Surface Engineering, LLC, under the leadership of Dr. Vladimir Gorokhovsky, is investigating filtered-arc and filtered-arc plasma-assisted hybrid coating deposition technologies to promote oxidation resistance, eliminate Cr volatility, and stabilize the electrical conductivity of both standard and specialty steel alloys of interest for SOFC metallic interconnect (IC) applications. Arcomac has successfully developed technologies and processes to deposit coatings with excellent adhesion, which have demonstrated a substantialmore » increase in high temperature oxidation resistance, stabilization of low Area Specific Resistance values and significantly decrease Cr volatility. An extensive matrix of deposition processes, coating compositions and architectures was evaluated. Technical performance of coated and uncoated sample coupons during exposures to SOFC interconnect-relevant conditions is discussed, and promising future directions are considered. Cost analyses have been prepared based on assessment of plasma processing parameters, which demonstrate the feasibility of the proposed surface engineering process for SOFC metallic IC applications.« less
Coppedê, Abílio Ricciardi; Bersani, Edmilson; de Mattos, Maria da Gloria Chiarello; Rodrigues, Renata Cristina Silveira; Sartori, Ivete Aparecida de Mattias; Ribeiro, Ricardo Faria
2009-01-01
The objective of this study was to verify if differences in the design of internal hex (IH) and internal conical (IC) connection implant systems influence fracture resistance under oblique compressive forces. Twenty implant-abutment assemblies were utilized: 10 with IH connections and 10 with IC connections. Maximum deformation force for IC implants (90.58 +/- 6.72 kgf) was statistically higher than that for IH implants (83.73 +/- 4.94 kgf) (P = .0182). Fracture force for the IH implants was 79.86 +/- 4.77 kgf. None of the IC implants fractured. The friction-locking mechanics and the solid design of the IC abutments provided greater resistance to deformation and fracture under oblique compressive loading when compared to the IH abutments.
Variational data assimilation system "INM RAS - Black Sea"
NASA Astrophysics Data System (ADS)
Parmuzin, Eugene; Agoshkov, Valery; Assovskiy, Maksim; Giniatulin, Sergey; Zakharova, Natalia; Kuimov, Grigory; Fomin, Vladimir
2013-04-01
Development of Informational-Computational Systems (ICS) for Data Assimilation Procedures is one of multidisciplinary problems. To study and solve these problems one needs to apply modern results from different disciplines and recent developments in: mathematical modeling; theory of adjoint equations and optimal control; inverse problems; numerical methods theory; numerical algebra and scientific computing. The problems discussed above are studied in the Institute of Numerical Mathematics of the Russian Academy of Science (INM RAS) in ICS for Personal Computers (PC). Special problems and questions arise while effective ICS versions for PC are being developed. These problems and questions can be solved with applying modern methods of numerical mathematics and by solving "parallelism problem" using OpenMP technology and special linear algebra packages. In this work the results on the ICS development for PC-ICS "INM RAS - Black Sea" are presented. In the work the following problems and questions are discussed: practical problems that can be studied by ICS; parallelism problems and their solutions with applying of OpenMP technology and the linear algebra packages used in ICS "INM - Black Sea"; Interface of ICS. The results of ICS "INM RAS - Black Sea" testing are presented. Efficiency of technologies and methods applied are discussed. The work was supported by RFBR, grants No. 13-01-00753, 13-05-00715 and by The Ministry of education and science of Russian Federation, project 8291, project 11.519.11.1005 References: [1] V.I. Agoshkov, M.V. Assovskii, S.A. Lebedev, Numerical simulation of Black Sea hydrothermodynamics taking into account tide-forming forces. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, 5-31 [2] E.I. Parmuzin, V.I. Agoshkov, Numerical solution of the variational assimilation problem for sea surface temperature in the model of the Black Sea dynamics. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, 69-94 [3] V.B. Zalesny, N.A. Diansky, V.V. Fomin, S.N. Moshonkin, S.G. Demyshev, Numerical model of the circulation of Black Sea and Sea of Azov. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, 95-111 [4] V.I. Agoshkov, S.V. Giniatulin, G.V. Kuimov. OpenMP technology and linear algebra packages in the variation data assimilation systems. - Abstracts of the 1-st China-Russia Conference on Numerical Algebra with Applications in Radiactive Hydrodynamics, Beijing, China, October 16-18, 2012. [5] Zakharova N.B., Agoshkov V.I., Parmuzin E.I., The new method of ARGO buoys system observation data interpolation. Russian Journal of Numerical Analysis and Mathematical Modelling. Vol. 28, Issue 1, 2013.
Chronic ethanol increases systemic TLR3 agonist-induced neuroinflammation and neurodegeneration
2012-01-01
Background Increasing evidence links systemic inflammation to neuroinflammation and neurodegeneration. We previously found that systemic endotoxin, a TLR4 agonist or TNFα, increased blood TNFα that entered the brain activating microglia and persistent neuroinflammation. Further, we found that models of ethanol binge drinking sensitized blood and brain proinflammatory responses. We hypothesized that blood cytokines contribute to the magnitude of neuroinflammation and that ethanol primes proinflammatory responses. Here, we investigate the effects of chronic ethanol on neuroinflammation and neurodegeneration triggered by toll-like receptor 3 (TLR3) agonist poly I:C. Methods Polyinosine-polycytidylic acid (poly I:C) was used to induce inflammatory responses when sensitized with D-galactosamine (D-GalN). Male C57BL/6 mice were treated with water or ethanol (5 g/kg/day, i.g., 10 days) or poly I:C (250 μg/kg, i.p.) alone or sequentially 24 hours after ethanol exposure. Cytokines, chemokines, microglial morphology, NADPH oxidase (NOX), reactive oxygen species (ROS), high-mobility group box 1 (HMGB1), TLR3 and cell death markers were examined using real-time PCR, ELISA, immunohistochemistry and hydroethidine histochemistry. Results Poly I:C increased blood and brain TNFα that peaked at three hours. Blood levels returned within one day, whereas brain levels remained elevated for at least three days. Escalating blood and brain proinflammatory responses were found with ethanol, poly I:C, and ethanol-poly I:C treatment. Ethanol pretreatment potentiated poly I:C-induced brain TNFα (345%), IL-1β (331%), IL-6 (255%), and MCP-1(190%). Increased levels of brain cytokines coincided with increased microglial activation, NOX gp91phox, superoxide and markers of neurodegeneration (activated caspase-3 and Fluoro-Jade B). Ethanol potentiation of poly I:C was associated with ethanol-increased expression of TLR3 and endogenous agonist HMGB1 in the brain. Minocycline and naltrexone blocked microglial activation and neurodegeneration. Conclusions Chronic ethanol potentiates poly I:C blood and brain proinflammatory responses. Poly I:C neuroinflammation persists after systemic responses subside. Increases in blood TNFα, IL-1β, IL-6, and MCP-1 parallel brain responses consistent with blood cytokines contributing to the magnitude of neuroinflammation. Ethanol potentiation of TLR3 agonist responses is consistent with priming microglia-monocytes and increased NOX, ROS, HMGB1-TLR3 and markers of neurodegeneration. These studies indicate that TLR3 agonists increase blood cytokines that contribute to neurodegeneration and that ethanol binge drinking potentiates these responses. PMID:22709825
Okeno, Tobias O; Magothe, Thomas M; Kahi, Alexander K; Peters, Kurt J
2013-01-01
A bio-economic model was developed to evaluate the utilisation of indigenous chickens (IC) under different production systems accounting for the risk attitude of the farmers. The model classified the production systems into three categories based on the level of management: free-range system (FRS), where chickens were left to scavenge for feed resources with no supplementation and healthcare; intensive system (IS), where the chickens were permanently confined and supplied with rationed feed and healthcare; and semi-intensive system (SIS), a hybrid of FRS and IS, where the chickens were partially confined, supplemented with rationed feeds, provided with healthcare and allowed to scavenge within the homestead or in runs. The model allows prediction of the live weights and feed intake at different stages in the life cycle of the IC and can compute the profitability of each production system using both traditional and risk-rated profit models. The input parameters used in the model represent a typical IC production system in developing countries but are flexible and therefore can be modified to suit specific situations and simulate profitability and costs of other poultry species production systems. The model has the capability to derive the economic values as changes in the genetic merit of the biological parameter results in marginal changes in profitability and costs of the production systems. The results suggested that utilisation of IC in their current genetic merit and production environment is more profitable under FRS and SIS but not economically viable under IS.
Simultaneous control of multiple instruments at the Advanced Technology Solar Telescope
NASA Astrophysics Data System (ADS)
Johansson, Erik M.; Goodrich, Bret
2012-09-01
The Advanced Technology Solar Telescope (ATST) is a 4-meter solar observatory under construction at Haleakala, Hawaii. The simultaneous use of multiple instruments is one of the unique capabilities that makes the ATST a premier ground based solar observatory. Control of the instrument suite is accomplished by the Instrument Control System (ICS), a layer of software between the Observatory Control System (OCS) and the instruments. The ICS presents a single narrow interface to the OCS and provides a standard interface for the instruments to be controlled. It is built upon the ATST Common Services Framework (CSF), an infrastructure for the implementation of a distributed control system. The ICS responds to OCS commands and events, coordinating and distributing them to the various instruments while monitoring their progress and reporting the status back to the OCS. The ICS requires no specific knowledge about the instruments. All information about the instruments used in an experiment is passed by the OCS to the ICS, which extracts and forwards the parameters to the appropriate instrument controllers. The instruments participating in an experiment define the active instrument set. A subset of those instruments must complete their observing activities in order for the experiment to be considered complete and are referred to as the must-complete instrument set. In addition, instruments may participate in eavesdrop mode, outside of the control of the ICS. All instrument controllers use the same standard narrow interface, which allows new instruments to be added without having to modify the interface or any existing instrument controllers.
Fuel Cell System Contaminants Material Screening Data: Text Version |
explore the results of fuel cell system contaminants studies. Total Anions [IC] and Total Concentration of Elements [ICP] in Leachate Solutions Material Class Manufacturer Trade Name and Use Grade ICP Total (ppm ) IC Total (ppm) Total Organic Carbon (ppm) Solution Conductivity (µS/cm) Adhesives LORD 2-part
A Survey of Security Tools for the Industrial Control System Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurd, Carl M.; McCarty, Michael V.
This report details the results of a survey conducted by Idaho National Laboratory (INL) to identify existing tools which could be used to prevent, detect, mitigate, or investigate a cyber-attack in an industrial control system (ICS) environment. This report compiles a list of potentially applicable tools and shows the coverage of the tools in an ICS architecture.
Expanding Combat Power Through Military Cyberpower Theory
2015-04-02
systems (ICS) and supervisory control and data acquisition systems ( SCADA ) are public-facing, providing more avenues of approach for an adversary. ICS...and SCADA are the two primary means for cyber adversaries to achieve direct physical effects through cyberspace. Strategic Attribution. From a...REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to
Balashov, A M; Selishchev, S V
2004-01-01
An integral chip (IC) was designed for controlling the step-down pulse voltage converter, which is based on the multiphase pulse-duration modulation, for use in biomedical microprocessor systems. The CMOS technology was an optimal basis for the IC designing. An additional feedback circuit diminishes the output voltage dispersion at dynamically changing loads.
Protecting ICS Systems Within the Energy Sector from Cyber Attacks
NASA Astrophysics Data System (ADS)
Barnes, Shaquille
Advance persistent threat (APT) groups are continuing to attack the energy sector through cyberspace, which poses a risk to our society, national security, and economy. Industrial control systems (ICSs) are not designed to handle cyber-attacks, which is why asset owners need to implement the correct proactive and reactive measures to mitigate the risk to their ICS environments. The Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) responded to 290 incidents for fiscal year 2016, where 59 of those incidents came from the Energy Sector. APT groups know how vulnerable energy sector ICS systems are and the destruction they can cause when they go offline such as loss of production, loss of life, and economic impact. Defending against APT groups requires more than just passive controls such as firewalls and antivirus solutions. Asset owners should implement a combination of best practices and active defense in their environment to defend against APT groups. Cyber-attacks against critical infrastructure will become more complex and harder to detect and respond to with traditional security controls. The purpose of this paper was to provide asset owners with the correct security controls and methodologies to help defend against APT groups.
NASA Astrophysics Data System (ADS)
Minnett, R.; Koppers, A.; Jarboe, N.; Tauxe, L.; Constable, C.; Jonestrask, L.
2017-12-01
Challenges are faced by both new and experienced users interested in contributing their data to community repositories, in data discovery, or engaged in potentially transformative science. The Magnetics Information Consortium (https://earthref.org/MagIC) has recently simplified its data model and developed a new containerized web application to reduce the friction in contributing, exploring, and combining valuable and complex datasets for the paleo-, geo-, and rock magnetic scientific community. The new data model more closely reflects the hierarchical workflow in paleomagnetic experiments to enable adequate annotation of scientific results and ensure reproducibility. The new open-source (https://github.com/earthref/MagIC) application includes an upload tool that is integrated with the data model to provide early data validation feedback and ease the friction of contributing and updating datasets. The search interface provides a powerful full text search of contributions indexed by ElasticSearch and a wide array of filters, including specific geographic and geological timescale filtering, to support both novice users exploring the database and experts interested in compiling new datasets with specific criteria across thousands of studies and millions of measurements. The datasets are not large, but they are complex, with many results from evolving experimental and analytical approaches. These data are also extremely valuable due to the cost in collecting or creating physical samples and the, often, destructive nature of the experiments. MagIC is heavily invested in encouraging young scientists as well as established labs to cultivate workflows that facilitate contributing their data in a consistent format. This eLightning presentation includes a live demonstration of the MagIC web application, developed as a configurable container hosting an isomorphic Meteor JavaScript application, MongoDB database, and ElasticSearch search engine. Visitors can explore the MagIC Database through maps and image or plot galleries or search and filter the raw measurements and their derived hierarchy of analytical interpretations.
A Development of Automatic Audit System for Written Informed Consent using Machine Learning.
Yamada, Hitomi; Takemura, Tadamasa; Asai, Takahiro; Okamoto, Kazuya; Kuroda, Tomohiro; Kuwata, Shigeki
2015-01-01
In Japan, most of all the university and advanced hospitals have implemented both electronic order entry systems and electronic charting. In addition, all medical records are subjected to inspector audit for quality assurance. The record of informed consent (IC) is very important as this provides evidence of consent from the patient or patient's family and health care provider. Therefore, we developed an automatic audit system for a hospital information system (HIS) that is able to evaluate IC automatically using machine learning.
Helguera, P R; Taborda, R; Docampo, D M; Ducasse, D A
2001-06-01
A detection system based on nested PCR after IC-RT-PCR (IC-RT-PCR-Nested PCR) was developed to improve indexing of Prunus necrotic ringspot virus in peach trees. Inhibitory effects and inconsistencies of the standard IC-RT-PCR were overcome by this approach. IC-RT-PCR-Nested PCR improved detection by three orders of magnitude compared with DAS-ELISA for the detection of PNRSV in leaves. Several different tissues were evaluated and equally consistent results were observed. The main advantages of the method are its consistency, high sensitivity and easy application in quarantine programs.
Liu, Yihang; Zhang, Wei; Zhu, Yujie; Luo, Yanting; Xu, Yunhua; Brown, Adam; Culver, James N; Lundgren, Cynthia A; Xu, Kang; Wang, Yuan; Wang, Chunsheng
2013-01-09
This work enables an elegant bottom-up solution to engineer 3D microbattery arrays as integral power sources for microelectronics. Thus, multilayers of functional materials were hierarchically architectured over tobacco mosaic virus (TMV) templates that were genetically modified to self-assemble in a vertical manner on current-collectors, so that optimum power and energy densities accompanied with excellent cycle-life could be achieved on a minimum footprint. The resultant microbattery based on self-aligned LiFePO(4) nanoforests of shell-core-shell structure, with precise arrangement of various auxiliary material layers including a central nanometric metal core as direct electronic pathway to current collector, delivers excellent energy density and stable cycling stability only rivaled by the best Li-ion batteries of conventional configurations, while providing rate performance per foot-print and on-site manufacturability unavailable from the latter. This approach could open a new avenue for microelectromechanical systems (MEMS) applications, which would significantly benefit from the concept that electrochemically active components be directly engineered and fabricated as an integral part of the integrated circuit (IC).
Consequence-driven cyber-informed engineering (CCE)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freeman, Sarah G.; St Michel, Curtis; Smith, Robert
The Idaho National Lab (INL) is leading a high-impact, national security-level initiative to reprioritize the way the nation looks at high-consequence risk within the industrial control systems (ICS) environment of the country’s most critical infrastructure and other national assets. The Consequence-driven Cyber-informed Engineering (CCE) effort provides both private and public organizations with the steps required to examine their own environments for high-impact events/risks; identify implementation of key devices and components that facilitate that risk; illuminate specific, plausible cyber attack paths to manipulate these devices; and develop concrete mitigations, protections, and tripwires to address the high-consequence risk. The ultimate goal ofmore » the CCE effort is to help organizations take the steps necessary to thwart cyber attacks from even top-tier, highly resourced adversaries that would result in a catastrophic physical effect. CCE participants are encouraged to work collaboratively with each other and with key U.S. Government (USG) contributors to establish a coalition, maximizing the positive effect of lessons-learned and further contributing to the protection of critical infrastructure and other national assets.« less
Gao, Zhouzheng; Zhang, Hongping; Ge, Maorong; Niu, Xiaoji; Shen, Wenbin; Wickert, Jens; Schuh, Harald
2015-03-10
The continuity and reliability of precise GNSS positioning can be seriously limited by severe user observation environments. The Inertial Navigation System (INS) can overcome such drawbacks, but its performance is clearly restricted by INS sensor errors over time. Accordingly, the tightly coupled integration of GPS and INS can overcome the disadvantages of each individual system and together form a new navigation system with a higher accuracy, reliability and availability. Recently, ionosphere-constrained (IC) precise point positioning (PPP) utilizing raw GPS observations was proven able to improve both the convergence and positioning accuracy of the conventional PPP using ionosphere-free combined observations (LC-PPP). In this paper, a new mode of tightly coupled integration, in which the IC-PPP instead of LC-PPP is employed, is implemented to further improve the performance of the coupled system. We present the detailed mathematical model and the related algorithm of the new integration of IC-PPP and INS. To evaluate the performance of the new tightly coupled integration, data of both airborne and vehicle experiments with a geodetic GPS receiver and tactical grade inertial measurement unit are processed and the results are analyzed. The statistics show that the new approach can further improve the positioning accuracy compared with both IC-PPP and the tightly coupled integration of the conventional PPP and INS.
Cheng, H W; Jeng, B M; Chen, C Y; Huang, H Y; Chiou, J C; Luo, C H
2013-01-01
This paper proposed a wireless power harvesting system with micro-electro-mechanical-systems (MEMS) fabrication for noninvasive intraocular pressure (IOP) measurement on soft contact lens substructure. The power harvesting IC consists of a loop antenna, an impedance matching network and a rectifier. The proposed IC has been designed and fabricated by CMOS 0.18 um process that operates at the ISM band of 5.8 GHz. The antenna and the power harvesting IC would be bonded together by using flip chip bonding technologies without extra wire interference. The circuit utilized an impedance transformation circuit to boost the input RF signal that improves the circuit performance. The proposed design achieves an RF-to-DC conversion efficiency of 35% at 5.8 GHz.
De Vleesschauwer, David; Chernin, Leonid; Höfte, Monica M
2009-01-01
Background Induced resistance is a state of enhanced defensive capacity developed by a plant reacting to specific biotic or chemical stimuli. Over the years, several forms of induced resistance have been characterized, including systemic acquired resistance, which is induced upon localized infection by an avirulent necrotizing pathogen, and induced systemic resistance (ISR), which is elicited by selected strains of nonpathogenic rhizobacteria. However, contrary to the relative wealth of information on inducible defense responses in dicotyledoneous plants, our understanding of the molecular mechanisms underlying induced resistance phenomena in cereal crops is still in its infancy. Using a combined cytomolecular and pharmacological approach, we analyzed the host defense mechanisms associated with the establishment of ISR in rice by the rhizobacterium Serratia plymuthica IC1270. Results In a standardized soil-based assay, root treatment with IC1270 rendered foliar tissues more resistant to the hemibiotrophic pathogen Magnaporthe oryzae, causal agent of the devastating rice blast disease. Analysis of the cytological and biochemical alterations associated with restriction of fungal growth in IC1270-induced plants revealed that IC1270 primes rice for enhanced attacker-induced accumulation of reactive oxygen species (ROS) and autofluorescent phenolic compounds in and near epidermal cells displaying dense cytoplasmic granulation. Similar, yet more abundant, phenotypes of hypersensitively dying cells in the vicinity of fungal hyphae were evident in a gene-for-gene interaction with an avirulent M. oryzae strain, suggesting that IC1270-inducible ISR and R protein conditioned effector-triggered immunity (ETI) target similar defense mechanisms. Yet, this IC1270-inducible ISR response seems to act as a double-edged sword within the rice defense network as induced plants displayed an increased vulnerability to the necrotrophic pathogens Rhizoctonia solani and Cochliobolus miyabeanus. Artificial enhancement of ROS levels in inoculated leaves faithfully mimicked the opposite effects of IC1270 bacteria on aforementioned pathogens, suggesting a central role for oxidative events in the IC1270-induced resistance mechanism. Conclusion Besides identifying ROS as modulators of antagonistic defense mechanisms in rice, this work reveals the mechanistic similarities between S. plymuthica-mediated ISR and R protein-dictated ETI and underscores the importance of using appropriate innate defense mechanisms when breeding for broad-spectrum rice disease resistance. PMID:19161601
De Vleesschauwer, David; Chernin, Leonid; Höfte, Monica M
2009-01-22
Induced resistance is a state of enhanced defensive capacity developed by a plant reacting to specific biotic or chemical stimuli. Over the years, several forms of induced resistance have been characterized, including systemic acquired resistance, which is induced upon localized infection by an avirulent necrotizing pathogen, and induced systemic resistance (ISR), which is elicited by selected strains of nonpathogenic rhizobacteria. However, contrary to the relative wealth of information on inducible defense responses in dicotyledoneous plants, our understanding of the molecular mechanisms underlying induced resistance phenomena in cereal crops is still in its infancy. Using a combined cytomolecular and pharmacological approach, we analyzed the host defense mechanisms associated with the establishment of ISR in rice by the rhizobacterium Serratia plymuthica IC1270. In a standardized soil-based assay, root treatment with IC1270 rendered foliar tissues more resistant to the hemibiotrophic pathogen Magnaporthe oryzae, causal agent of the devastating rice blast disease. Analysis of the cytological and biochemical alterations associated with restriction of fungal growth in IC1270-induced plants revealed that IC1270 primes rice for enhanced attacker-induced accumulation of reactive oxygen species (ROS) and autofluorescent phenolic compounds in and near epidermal cells displaying dense cytoplasmic granulation. Similar, yet more abundant, phenotypes of hypersensitively dying cells in the vicinity of fungal hyphae were evident in a gene-for-gene interaction with an avirulent M. oryzae strain, suggesting that IC1270-inducible ISR and R protein conditioned effector-triggered immunity (ETI) target similar defense mechanisms. Yet, this IC1270-inducible ISR response seems to act as a double-edged sword within the rice defense network as induced plants displayed an increased vulnerability to the necrotrophic pathogens Rhizoctonia solani and Cochliobolus miyabeanus. Artificial enhancement of ROS levels in inoculated leaves faithfully mimicked the opposite effects of IC1270 bacteria on aforementioned pathogens, suggesting a central role for oxidative events in the IC1270-induced resistance mechanism. Besides identifying ROS as modulators of antagonistic defense mechanisms in rice, this work reveals the mechanistic similarities between S. plymuthica-mediated ISR and R protein-dictated ETI and underscores the importance of using appropriate innate defense mechanisms when breeding for broad-spectrum rice disease resistance.
Byun, Youngjae; Rodriguez, Katia; Han, Jung H; Kim, Young Teck
2015-11-01
The effects of the incorporation of PLA-β-cyclodextrin-inclusion complex (IC) and β-cyclodextrin (β-CD) on biopolyester PLA films were investigated. Thermal stability, surface morphology, barrier, and mechanical properties of the films were measured at varying IC (1, 3, 5, and 7%) and β-CD (1 and 5%) concentrations. The PLA-IC-composite films (IC-PLA-CFs) showed uniform morphological structure, while samples containing β-CD (β-CD-PLA-CFs) showed high agglomeration of β-CD due to poor interfacial interaction between β-CD and PLA moieties. According to the thermal property analysis, the 5% IC-PLA-CFs showed 6.6 times lower dimensional changes (6.5%) at the temperature range of 20-80°C than that of pure PLA film (43.0%). The increase of IC or β-CD content in the PLA-composite films shifted the glass transition and crystallization temperature to higher temperature regions. The crystallinity of both composite films improved by increasing IC or β-CD content. Both composite films had higher oxygen and water vapor permeability as IC or β-CD content increased in comparison to pure PLA film. All the composite films had less flexibility and lower tensile strength than the pure PLA film. In conclusion, this study shows that the IC technique is valuable to improve the thermal expansion stability of PLA-based films. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Kumar, Parveen; Wani, M. F.
2017-11-01
Researchers reported that the IC engine components (piston, cylinder liner etc) fail due to the friction losses (~45%) and wear losses (~25-40%). So the demand of light weight, low friction and wear resistance alloys increases day by day, which reduces the emission and increases the efficiency of the IC engine. In this connection, tribological tests on hypereutectic Al-25Si alloy were performed using a ball-on-disk configuration under dry and lubricated sliding conditions. Hypereutectic Al-25Si alloy was prepared by rapid solidification process with T6 condition. T6 condition improves the friction, wear and mechanical properties of the alloy. Friction coefficient and wear rate of the alloy was measured under high loads ranging from 100 to 300 N. It was found that the friction coefficient (COF) and wear rate of hypereutectic Al-25Si alloy/steel tribo pair increased with increase in load. Significant reduction in COF and wear rate was accomplished with SAE20W50 engine oil and Si particles act as solid lubricant. Optical microscope, 3D surface profilometer and scanning electron microscope (SEM) coupled with an energy dispersive spectrometer (EDS) were used for characterization the worn surface morphologies. The morphology, size and distribution of high Si particles due to its fabrication process caused the improvements in COF and wear rate under lubricated conditions. Adhesive wear, abrasive wear and plastic deformation acted as the dominant wear mechanism for hypereutectic Al-25Si alloy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blaser, Richard
1980-11-01
This compilation, a draft training manual containing technical background information on internal combustion engines and alcohol motor fuel technologies, is presented in 3 parts. The first is a compilation of facts from the state of the art on internal combustion engine fuels and their characteristics and requisites and provides an overview of fuel sources, fuels technology and future projections for availability and alternatives. Part two compiles facts about alcohol chemistry, alcohol identification, production, and use, examines ethanol as spirit and as fuel, and provides an overview of modern evaluation of alcohols as motor fuels and of the characteristics of alcoholmore » fuels. The final section compiles cross references on the handling and combustion of fuels for I.C. engines, presents basic evaluations of events leading to the use of alcohols as motor fuels, reviews current applications of alcohols as motor fuels, describes the formulation of alcohol fuels for engines and engine and fuel handling hardware modifications for using alcohol fuels, and introduces the multifuel engines concept. (LCL)« less
NASA Technical Reports Server (NTRS)
Wells, James; Scherrer, John; Van Noord, Jonathan; Law, Richard
2015-01-01
In response to the recommendations made in the National Research Council' s Ear th Science and Applications 2007 Decadal Sur vey, NASA has initiated the Ear th Venture line of mission oppor tunities. The fir st orbital mission chosen for this competitively selected, cost and schedule constrained, Pr incipal Investigator -led oppor tunity is the CYclone Global Navigation Satellite System (CYGNSS). The goal of CYGNSS is to understand the coupling between ocean sur face proper ties, moist atmospher ic thermodynamics, radiation, and convective dynamics in the inner core of a tropical cyclone. The CYGNSS mission is compr ised of eight Low Ear th Obser ving (LEO) micr osatellites that use GPS bi-static scatterometry to measure ocean sur face winds.
Truman, C C; Strickland, T C; Potter, T L; Franklin, D H; Bosch, D D; Bednarz, C W
2007-01-01
The low-carbon, intensively cropped Coastal Plain soils of Georgia are susceptible to runoff, soil loss, and drought. Reduced tillage systems offer the best management tool for sustained row crop production. Understanding runoff, sediment, and chemical losses from conventional and reduced tillage systems is expected to improve if the effect of a variable rainfall intensity storm was quantified. Our objective was to quantify and compare effects of a constant (Ic) intensity pattern and a more realistic, observed, variable (Iv) rainfall intensity pattern on runoff (R), sediment (E), and carbon losses (C) from a Tifton loamy sand cropped to conventional-till (CT) and strip-till (ST) cotton (Gossypium hirsutum L.). Four treatments were evaluated: CT-Ic, CT-Iv, ST-Ic, and ST-Iv, each replicated three times. Field plots (n=12), each 2 by 3 m, were established on each treatment. Each 6-m2 field plot received simulated rainfall at a constant (57 mm h(-1)) or variable rainfall intensity pattern for 70 min (12-run ave.=1402 mL; CV=3%). The Iv pattern represented the most frequent occurring intensity pattern for spring storms in the region. Compared with CT, ST decreased R by 2.5-fold, E by 3.5-fold, and C by 7-fold. Maximum runoff values for Iv events were 1.6-fold higher than those for Ic events and occurred 38 min earlier. Values for Etot and Ctot for Iv events were 19-36% and 1.5-fold higher than corresponding values for Ic events. Values for Emax and Cmax for Iv events were 3-fold and 4-fold higher than corresponding values for Ic events. Carbon enrichment ratios (CER) were
Ohyama, Kaname; Yoshimi, Haruka; Aibara, Nozomi; Nakamura, Yoichi; Miyata, Yasuyoshi; Sakai, Hideki; Fujita, Fumihiko; Imaizumi, Yoshitaka; Chauhan, Anil K; Kishikawa, Naoya; Kuroda, Naotaka
2017-01-15
Cancer immunotherapies such as antibodies targeting T cell checkpoints, or adaptive tumor-infiltrating lymphocyte (TIL) transfer, have been developed to boost the endogenous immune response against human malignancies. However, activation of T cells by such antibodies can lead to the risk of autoimmune diseases. Also, the selection of tumor-reactive T cells for TIL relies on information regarding mutated antigens in tumors and does not reflect other factors involved in protein antigenicity. It is therefore essential to engineer therapeutic interventions by which T cell reactivity against tumor cells is selectively enhanced (i.e., "focused cancer immunotherapy") based on tumor antigens that are specifically expressed in the tumor of a certain cancer and in many patients with this cancer. Immune complexes (ICs) are the direct and stable products of immunological recognition by humoral immunity. Here, we searched for tumor-specific IC antigens in each of five cancers (lung (n = 28), colon (n = 20), bladder (n = 20), renal cell (n = 15) and malignant lymphoma (n = 9)), by using immune complexome analysis that comprehensively identifies and profiles the constituent antigens in ICs. This analysis indicated that gelsolin and inter-alpha-trypsin inhibitor heavy chains were specifically and frequently detected (at a frequency higher than 80%), and that phosphoproteins (VENTX, VCIP135) were also specifically present in the ICs of lung cancer patients. Immune complexome analysis successfully identified several tumor-specific IC antigens with high detection frequency in lung cancer patients. These specific antigens are required to validate the clinical benefit by further analysis using a large number of patients. © 2016 UICC.
1963-04-17
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph taken April 17, 1963, gives a look at the four tower legs of the S-IC test stand at their completed height.
1963-11-20
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the progress of the S-IC test stand as of November 20, 1963.
1963-02-25
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph taken February 25, 1963, gives a close up look at two of the ever-growing four towers of the S-IC Test Stand.
1963-05-07
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph, taken from ground level on May 7, 1963, gives a close look at one of the four towers legs of the S-IC test stand nearing its completed height.
1963-05-07
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph, taken May 7, 1963, gives a close look at the four concrete tower legs of the S-IC test stand at their completed height.
1963-09-18
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. This photograph taken September 18, 1963 shows a spherical hydrogen tank being constructed next to the S-IC test stand.
1963-10-10
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the progress of the S-IC test stand as of October 10, 1963. Kerosene storage tanks can be seen to the left.
1961-09-07
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the construction progress of the S-IC test stand as of September 7, 1961.
Construction Progress of the S-IC Test Stand-Steel Reinforcements
NASA Technical Reports Server (NTRS)
1961-01-01
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, taken September 15, 1961, shows the installation of the reinforcing steel prior to the pouring of the concrete foundation walls.
1961-07-10
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this photo, taken July 10, 1961, actual ground breaking has occurred for the S-IC test stand site.
Cost optimization in low volume VLSI circuits
NASA Technical Reports Server (NTRS)
Cook, K. B., Jr.; Kerns, D. V., Jr.
1982-01-01
The relationship of integrated circuit (IC) cost to electronic system cost is developed using models for integrated circuit cost which are based on design/fabrication approach. Emphasis is on understanding the relationship between cost and volume for custom circuits suitable for NASA applications. In this report, reliability is a major consideration in the models developed. Results are given for several typical IC designs using off the shelf, full custom, and semicustom IC's with single and double level metallization.
Implementing New Non-Chromate Coatings Systems (Briefing Charts)
2011-02-09
Initiate Cr6+ authorization process for continued Cr6+ use using the form, Authorization to Use Hexavalent Chromium. YES NO • Approval of...Aluminum and magnesium anodizing • Hard Chrome Plating • Type II conversion coating on aluminum alloys under chromated primer • Type II conversion coating...Elimination of Hexavalent Chromium 80% 5% 14% 1% Type II Type III Type IC Type IC Fatigue Critical 50% 50% Type II Type IC FRC-SE (JAX) Fully Integrated FRC
Herpes simplex virus vector-mediated gene delivery for the treatment of lower urinary tract pain
Goins, WF; Goss, JR; Chancellor, MB; de Groat, WC; Glorioso, JC; Yoshimura, N
2009-01-01
Interstitial cystitis (IC)/painful bladder syndrome (PBS) is a painful debilitating chronic visceral pain disorder of unknown etiology that affects an estimated 1 million people in the, United States alone. It is characterized by inflammation of the bladder that results in chronic pelvic pain associated with bladder symptoms of urinary frequency and urgency. Regardless of the etiology, IC/PBS involves either increased and/or abnormal activity in afferent nociceptive sensory neurons. Pain-related symptoms in patients with IC/PBS are often very difficult to treat. Both medical and surgical therapies have had limited clinical utility in this debilitating disease and numerous drug treatments, such as heparin, dimethylsulfoxide and amitriptyline, have proven to be palliative at best, and in some IC/PBS patients provide no relief whatsoever. Although opiate narcotics have been employed to help alleviate IC/PBS pain, this strategy is fraught with problems as systemic narcotic administration causes multiple unwanted side effects including mental status change and constipation. Moreover, chronic systemic narcotic use leads to dependency and need for dose escalation due to tolerance: therefore, new therapies are desperately needed to treat refractory IC/PBS. This has led our group to develop a gene therapy strategy that could potentially alleviate chronic pelvic pain using the herpes simplex virus-directed delivery of analgesic proteins to the bladder. PMID:19242523
Quinn, Emma; Johnstone, Travers; Najjar, Zeina; Cains, Toni; Tan, Geoff; Huhtinen, Essi; Nilsson, Sven; Burgess, Stuart; Dunn, Matthew; Gupta, Leena
2017-09-05
The incident command system (ICS) provides a common structure to control and coordinate an emergency response, regardless of scale or predicted impact. The lessons learned from the application of an ICS for large infectious disease outbreaks are documented. However, there is scant evidence on the application of an ICS to manage a local multiagency response to a disease cluster with environmental health risks. The Sydney Local Health District Public Health Unit (PHU) in New South Wales, Australia, was notified of 5 cases of Legionnaires' disease during 2 weeks in May 2016. This unusual incident triggered a multiagency investigation involving an ICS with staff from the PHU, 3 local councils, and the state health department to help prevent any further public health risk. The early and judicious use of ICS enabled a timely and effective response by supporting clear communication lines between the incident controller and field staff. The field team was key in preventing any ongoing public health risk through inspection, sampling, testing, and management of water systems identified to be at-risk for transmission of legionella. Good working relationships between partner agencies and trust in the technical proficiency of environmental health staff aided in the effective management of the response. (Disaster Med Public Health Preparedness. 2017;page 1 of 4).
The next generation in optical transport semiconductors: IC solutions at the system level
NASA Astrophysics Data System (ADS)
Gomatam, Badri N.
2005-02-01
In this tutorial overview, we survey some of the challenging problems facing Optical Transport and their solutions using new semiconductor-based technologies. Advances in 0.13um CMOS, SiGe/HBT and InP/HBT IC process technologies and mixed-signal design strategies are the fundamental breakthroughs that have made these solutions possible. In combination with innovative packaging and transponder/transceiver architectures IC approaches have clearly demonstrated enhanced optical link budgets with simultaneously lower (perhaps the lowest to date) cost and manufacturability tradeoffs. This paper will describe: *Electronic Dispersion Compensation broadly viewed as the overcoming of dispersion based limits to OC-192 links and extending link budgets, *Error Control/Coding also known as Forward Error Correction (FEC), *Adaptive Receivers for signal quality monitoring for real-time estimation of Q/OSNR, eye-pattern, signal BER and related temporal statistics (such as jitter). We will discuss the theoretical underpinnings of these receiver and transmitter architectures, provide examples of system performance and conclude with general market trends. These Physical layer IC solutions represent a fundamental new toolbox of options for equipment designers in addressing systems level problems. With unmatched cost and yield/performance tradeoffs, it is expected that IC approaches will provide significant flexibility in turn, for carriers and service providers who must ultimately manage the network and assure acceptable quality of service under stringent cost constraints.
Numerical simulation of the flow field and fuel sprays in an IC engine
NASA Technical Reports Server (NTRS)
Nguyen, H. L.; Schock, H. J.; Ramos, J. I.; Carpenter, M. H.; Stegeman, J. D.
1987-01-01
A two-dimensional model for axisymmetric piston-cylinder configurations is developed to study the flow field in two-stroke direct-injection Diesel engines under motored conditions. The model accounts for turbulence by a two-equation model for the turbulence kinetic energy and its rate of dissipation. A discrete droplet model is used to simulate the fuel spray, and the effects of the gas phase turbulence on the droplets is considered. It is shown that a fluctuating velocity can be added to the mean droplet velocity every time step if the step is small enough. Good agreement with experimental data is found for a range of ambient pressures in Diesel engine-type microenvironments. The effects of the intake swirl angle in the spray penetration, vaporization, and mixing in a uniflow-scavenged two-stroke Diesel engine are analyzed. It is found that the swirl increases the gas phase turbulence levels and the rates of vaporization.
SU-E-T-547: Rotating Shield Brachytherapy (RSBT) for Cervical Cancer.
Yang, W; Kim, Y; Liu, Y; Wu, X; Flynn, R
2012-06-01
To assess rotating shield brachytherapy (RSBT) delivered with the electronic brachytherapy (eBT) source comparing to intracavitary (IC) and intracavitary plus supplemental interstitial brachytherapy (IC+IS BT) delivered with conventional isotope radiation source. IC, IC+IS and RSBT plan was simulated for 5 patients with advanced cervical cancer (>40cc). One BT plan for each patient (fraction 1) guided by magnetic resonance imaging (MRI) was used in our treatment planning system (TPS). A bio- and MRI-compatible polycarbonate (Makrolon Rx3158) intrauterine applicator was simulated for IC and RSBT, and the vienna applicator was simulated for IC+IS BT. 192Ir was used as the radiation source of IC and IC+IS BT; Xoft AxxentTM eBT source was used for RSBT. A 0.5 mm thick tungsten shield was used for RS-BT with different azimuthal and zenith angles. The total dose for each plan was escalated as the external beam radiation therapy (EBRT) plus BT times fraction number (5 in our case). RSBT and IC+IS BT had higher dose conformity in terms of D90 than IC BT for all the patients. The advantage of RSBT over IC+IS BT was dependent on the shield emission angle, tumor shape and tandem applicator location. The delivery time of RSBT was increased as finer emission angle was selected. RSBT is a less-invasive potential alternative to conventional IC and IC+IS BT for treating bulky (>40cc) cervical cancer. RSBT can provide better treatment outcome with clinically acceptable increased delivery time if proper emission angle is selected based on the tumor shape and tandem applicator location. supported in part by NSF grants CCF-0830402 and CCF-0844765; and the NIH grant K25-CA123112, and American Cancer Society seed grant (IRG-77-004-31). © 2012 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Lee, Kihyung; Reitz, Rolf D.
2004-03-01
Homogeneous charge compression ignition (HCCI) combustion provides extremely low levels of pollutant emissions, and thus is an attractive alternative for future IC engines. In order to achieve a uniform mixture distribution within the engine cylinder, the characteristics of the fuel spray play an important role in the HCCI engine concept. It is well known that high-pressure common rail injection systems, mainly used in diesel engines, achieve poor mixture formation because of the possibility of direct fuel impingement on the combustion chamber surfaces. This paper describes spray characteristics of a low-pressure common rail injector which is intended for use in an HCCI engine. Optical diagnostics including laser diffraction and phase Doppler methods, and high-speed camera photography, were applied to measure the spray drop diameter and to investigate the spray development process. The drop sizing results of the laser diffraction method were compared with those of a phase Doppler particle analyser (PDPA) to validate the accuracy of the experiments. In addition, the effect of fuel properties on the spray characteristics was investigated using n-heptane, Stoddard solvent (gasoline surrogate) and diesel fuel because HCCI combustion is sensitive to the fuel composition. The results show that the injector forms a hollow-cone sheet spray rather than a liquid jet, and the atomization efficiency is high (small droplets are produced). The droplet SMD ranged from 15 to 30 µm. The spray break-up characteristics were found to depend on the fuel properties. The break-up time for n-heptane is shorter and the drop SMD is smaller than that of Stoddard solvent and diesel fuel.
Modular integration of electronics and microfluidic systems using flexible printed circuit boards.
Wu, Amy; Wang, Lisen; Jensen, Erik; Mathies, Richard; Boser, Bernhard
2010-02-21
Microfluidic systems offer an attractive alternative to conventional wet chemical methods with benefits including reduced sample and reagent volumes, shorter reaction times, high-throughput, automation, and low cost. However, most present microfluidic systems rely on external means to analyze reaction products. This substantially adds to the size, complexity, and cost of the overall system. Electronic detection based on sub-millimetre size integrated circuits (ICs) has been demonstrated for a wide range of targets including nucleic and amino acids, but deployment of this technology to date has been limited due to the lack of a flexible process to integrate these chips within microfluidic devices. This paper presents a modular and inexpensive process to integrate ICs with microfluidic systems based on standard printed circuit board (PCB) technology to assemble the independently designed microfluidic and electronic components. The integrated system can accommodate multiple chips of different sizes bonded to glass or PDMS microfluidic systems. Since IC chips and flex PCB manufacturing and assembly are industry standards with low cost, the integrated system is economical for both laboratory and point-of-care settings.
1980-08-01
4 985 G DEPARTMENT OF THE ARMY [ NEW ENGLAND DIVISION, CORPS OF ENGINEERS WALTHAM, MASS. 02154 * DI~~~~h~ U~M ~qE M W A " AUGUST 1_App buomr w...AODREO9(if diffemen IC l mMA OfUice) IS. SECURITY CLASS. (of ShJi r.90,) UNCLASSIFIED IS. DC-ASSI FIC ATION/DOWNGRADIN G SCN DULE I6. DISTRIBUTION... g . Purpose of Dam 2 h. Design and Construction History 3 i. Normal Operational Procedure 3 1.3 Pertinent Data 3 2. ENGINEERING DATA 2.1 Design
A Portable Parallel Implementation of the U.S. Navy Layered Ocean Model
1995-01-01
Wallcraft, PhD (I.C. 1981) Planning Systems Inc. & P. R. Moore, PhD (Camb. 1971) IC Dept. Math. DR Moore 1° Encontro de Metodos Numericos...Kendall Square, Hypercube, D R Moore 1 ° Encontro de Metodos Numericos para Equacöes de Derivadas Parciais A. J. Wallcraft IC Mathematics...chips: Chips Machine DEC Alpha CrayT3D/E SUN Sparc Fujitsu AP1000 Intel 860 Paragon D R Moore 1° Encontro de Metodos Numericos para Equacöes
Optimizing a synchrotron based x-ray lithography system for IC manufacturing
NASA Astrophysics Data System (ADS)
Kovacs, Stephen; Speiser, Kenneth; Thaw, Winston; Heese, Richard N.
1990-05-01
The electron storage ring is a realistic solution as a radiation source for production grade, industrial X-ray lithography system. Today several large scale plans are in motion to design and implement synchrotron storage rings of different types for this purpose in the USA and abroad. Most of the scientific and technological problems related to the physics, design and manufacturing engineering, and commissioning of these systems for microlithography have been resolved or are under extensive study. However, investigation on issues connected to application of Synchrotron Orbit Radiation (SOR ) in chip production environment has been somewhat neglected. In this paper we have filled this gap pointing out direct effects of some basic synchrotron design parameters and associated subsystems (injector, X-ray beam line) on the operation and cost of lithography in production. The following factors were considered: synchrotron configuration, injection energy, beam intensity variability, number of beam lines and wafer exposure concept. A cost model has been worked out and applied to three different X-ray Lithography Source (XLS) systems. The results of these applications are compared and conclusions drawn.
Technology CAD for integrated circuit fabrication technology development and technology transfer
NASA Astrophysics Data System (ADS)
Saha, Samar
2003-07-01
In this paper systematic simulation-based methodologies for integrated circuit (IC) manufacturing technology development and technology transfer are presented. In technology development, technology computer-aided design (TCAD) tools are used to optimize the device and process parameters to develop a new generation of IC manufacturing technology by reverse engineering from the target product specifications. While in technology transfer to manufacturing co-location, TCAD is used for process centering with respect to high-volume manufacturing equipment of the target manufacturing equipment of the target manufacturing facility. A quantitative model is developed to demonstrate the potential benefits of the simulation-based methodology in reducing the cycle time and cost of typical technology development and technology transfer projects over the traditional practices. The strategy for predictive simulation to improve the effectiveness of a TCAD-based project, is also discussed.
NASA Astrophysics Data System (ADS)
Lavrov, V. V.; Spirin, N. A.
2016-09-01
Advances in modern science and technology are inherently connected with the development, implementation, and widespread use of computer systems based on mathematical modeling. Algorithms and computer systems are gaining practical significance solving a range of process tasks in metallurgy of MES-level (Manufacturing Execution Systems - systems controlling industrial process) of modern automated information systems at the largest iron and steel enterprises in Russia. This fact determines the necessity to develop information-modeling systems based on mathematical models that will take into account the physics of the process, the basics of heat and mass exchange, the laws of energy conservation, and also the peculiarities of the impact of technological and standard characteristics of raw materials on the manufacturing process data. Special attention in this set of operations for metallurgic production is devoted to blast-furnace production, as it consumes the greatest amount of energy, up to 50% of the fuel used in ferrous metallurgy. The paper deals with the requirements, structure and architecture of BF Process Engineer's Automated Workstation (AWS), a computer decision support system of MES Level implemented in the ICS of the Blast Furnace Plant at Magnitogorsk Iron and Steel Works. It presents a brief description of main model subsystems as well as assumptions made in the process of mathematical modelling. Application of the developed system allows the engineering and process staff to analyze online production situations in the blast furnace plant, to solve a number of process tasks related to control of heat, gas dynamics and slag conditions of blast-furnace smelting as well as to calculate the optimal composition of blast-furnace slag, which eventually results in increasing technical and economic performance of blast-furnace production.
Identification of Modeling Approaches To Support Common-Cause Failure Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korsah, Kofi; Wood, Richard Thomas
2015-06-01
Experience with applying current guidance and practices for common-cause failure (CCF) mitigation to digital instrumentation and control (I&C) systems has proven problematic, and the regulatory environment has been unpredictable. The impact of CCF vulnerability is to inhibit I&C modernization and, thereby, challenge the long-term sustainability of existing plants. For new plants and advanced reactor concepts, the issue of CCF vulnerability for highly integrated digital I&C systems imposes a design burden resulting in higher costs and increased complexity. The regulatory uncertainty regarding which mitigation strategies are acceptable (e.g., what diversity is needed and how much is sufficient) drives designers to adoptmore » complicated, costly solutions devised for existing plants. The conditions that constrain the transition to digital I&C technology by the U.S. nuclear industry require crosscutting research to resolve uncertainty, demonstrate necessary characteristics, and establish an objective basis for qualification of digital technology for usage in Nuclear Power Plant (NPP) I&C applications. To fulfill this research need, Oak Ridge National Laboratory is conducting an investigation into mitigation of CCF vulnerability for nuclear-qualified applications. The outcome of this research is expected to contribute to a fundamentally sound, comprehensive technical basis for establishing the qualification of digital technology for nuclear power applications. This report documents the investigation of modeling approaches for representing failure of I&C systems. Failure models are used when there is a need to analyze how the probability of success (or failure) of a system depends on the success (or failure) of individual elements. If these failure models are extensible to represent CCF, then they can be employed to support analysis of CCF vulnerabilities and mitigation strategies. Specifically, the research findings documented in this report identify modeling approaches that can be adapted to contribute to the basis for developing systematic methods, quantifiable measures, and objective criteria for evaluating CCF vulnerabilities and mitigation strategies.« less
Taxonomy for Common-Cause Failure Vulnerability and Mitigation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, Richard Thomas; Korsah, Kofi; Mullens, James Allen
2015-09-01
Applying current guidance and practices for common-cause failure (CCF) mitigation to digital instrumentation and control (I&C) systems has proven problematic, and the regulatory environment has been unpredictable. The potential for CCF vulnerability inhibits I&C modernization, thereby challenging the long-term sustainability of existing plants. For new plants and advanced reactor concepts, concern about CCF vulnerability in highly integrated digital I&C systems imposes a design burden that results in higher costs and increased complexity. The regulatory uncertainty in determining which mitigation strategies will be acceptable (e.g., what diversity is needed and how much is sufficient) drives designers to adopt complicated, costly solutionsmore » devised for existing plants. To address the conditions that constrain the transition to digital I&C technology by the US nuclear industry, crosscutting research is needed to resolve uncertainty, demonstrate necessary characteristics, and establish an objective basis for qualification of digital technology for nuclear power plant (NPP) I&C applications. To fulfill this research need, Oak Ridge National Laboratory is investigating mitigation of CCF vulnerability for nuclear-qualified applications. The outcome of this research is expected to contribute to a fundamentally sound, comprehensive basis to qualify digital technology for nuclear power applications. This report documents the development of a CCF taxonomy. The basis for the CCF taxonomy was generated by determining consistent terminology and establishing a classification approach. The terminology is based on definitions from standards, guides, and relevant nuclear power industry technical reports. The classification approach is derived from identified classification schemes focused on I&C systems and key characteristics, including failure modes. The CCF taxonomy provides the basis for a systematic organization of key systems aspects relevant to analyzing the potential for CCF vulnerability and the suitability of mitigation techniques. Development of an effective CCF taxonomy will help to provide a framework for establishing the objective analysis and assessment capabilities desired to facilitate rigorous identification of fault types and triggers that are the fundamental elements of CCF.« less
Imbe, H; Kimura, A; Donishi, T; Kaneoke, Y
2014-02-14
Stress affects brain activity and promotes long-term changes in multiple neural systems. Exposure to stressors causes substantial effects on the perception and response to pain. In several animal models, chronic stress produces lasting hyperalgesia. The insular (IC) and anterior cingulate cortices (ACC) are the regions exhibiting most reliable pain-related activity. And the IC and ACC play an important role in pain modulation via the descending pain modulatory system. In the present study we examined the expression of phospho-cAMP response element-binding protein (pCREB) and c-Fos in the IC and ACC after forced swim stress (FS) and complete Freund's adjuvant (CFA) injection to clarify changes in the cerebral cortices that affect the activity of the descending pain modulatory system in the rats with stress-induced hyperalgesia. FS (day 1, 10min; days 2-3, 20min) induced an increase in the expression of pCREB and c-Fos in the anterior IC (AIC). CFA injection into the hindpaw after the FS shows significantly enhanced thermal hyperalgesia and induced a decrease in the expression of c-Fos in the AIC and the posterior IC (PIC). Quantitative image analysis showed that the numbers of c-Fos-immunoreactive neurons in the left AIC and PIC were significantly lower in the FS+CFA group (L AIC, 95.9±6.8; L PIC, 181.9±23.1) than those in the naive group (L AIC, 151.1±19.3, p<0.05; L PIC, 274.2±37.3, p<0.05). These findings suggest a neuroplastic change in the IC after FS, which may be involved in the enhancement of CFA-induced thermal hyperalgesia through dysfunction of the descending pain modulatory system. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.
Post-test analysis of PIPER-ONE PO-IC-2 experiment by RELAP5/MOD3 codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bovalini, R.; D`Auria, F.; Galassi, G.M.
1996-11-01
RELAP5/MOD3.1 was applied to the PO-IC-2 experiment performed in PIPER-ONE facility, which has been modified to reproduce typical isolation condenser thermal-hydraulic conditions. RELAP5 is a well known code widely used at the University of Pisa during the past seven years. RELAP5/MOD3.1 was the latest version of the code made available by the Idaho National Engineering Laboratory at the time of the reported study. PIPER-ONE is an experimental facility simulating a General Electric BWR-6 with volume and height scaling ratios of 1/2,200 and 1./1, respectively. In the frame of the present activity a once-through heat exchanger immersed in a pool ofmore » ambient temperature water, installed approximately 10 m above the core, was utilized to reproduce qualitatively the phenomenologies expected for the Isolation Condenser in the simplified BWR (SBWR). The PO-IC-2 experiment is the flood up of the PO-SD-8 and has been designed to solve some of the problems encountered in the analysis of the PO-SD-8 experiment. A very wide analysis is presented hereafter including the use of different code versions.« less
Purification, characterization, and biological activities of broccolini lectin.
Xu, Pingping; Zhang, Ting; Guo, Xiaolei; Ma, Chungwah; Zhang, Xuewu
2015-01-01
Plant lectins have displayed a variety of biological activities. In this study, for the first time, a 27 kDa arabinose- and mannose-specific lectin from Broccolini (Brassica oleracea Italica × Alboglabra), named as BL (Broccolini lectin), was purified by an activity-driven protocol. Mass spectrometry analysis and database search indicated that no matches with any plant lectin were found, but BL contained some peptide fragments (QQQGQQGQQLQQVISR, QQGQQQGQQGQQLQQVISR and VCNIPQVSVCPF QK). BL exhibited hemagglutinating activity against chicken erythrocytes at 4 µg/mL. BL retained full hemagglutinating activity at pH 7-8 and temperature 30-40°C, and had an optimal activity in Ca(2+) solution. Bioactivity assay revealed that BL exhibited dose-dependent inhibition activity on 5 bacterial species with IC50 values of 143.95-486.33 μg/mL, and on 3 cancer cells with IC50 values of 178.82-350.93 μg/mL. Notably, 5-fold reduction in IC50 values was observed on normal L-O2 vs cancerous HepG-2 cells (924.35 vs. 178.82 μg/mL). This suggests that BL should be promising in food and medicine. © 2015 American Institute of Chemical Engineers.
Embedded I&C for Extreme Environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kisner, Roger A.
2016-04-01
This project uses embedded instrumentation and control (I&C) technologies to demonstrate potential performance gains of nuclear power plant components in extreme environments. Extreme environments include high temperature, radiation, high pressure, high vibration, and high EMI conditions. For extreme environments, performance gains arise from moment-to-moment sensing of local variables and immediate application of local feedback control. Planning for embedding I&C during early system design phases contrasts with the traditional, serial design approach that incorporates minimal I&C after mechanical and electrical design is complete. The demonstration application involves the development and control of a novel, proof-of-concept motor/pump design. The motor and pumpmore » combination operate within the fluid environment, eliminating the need for rotating seals. Actively controlled magnetic bearings also replace failure-prone mechanical contact bearings that typically suspend rotating components. Such as design has the potential to significantly enhance the reliability and life of the pumping system and would not be possible without embedded I&C.« less
Liu, Yu; Leng, Shuai; Michalak, Gregory J; Vrieze, Thomas J; Duan, Xinhui; Qu, Mingliang; Shiung, Maria M; McCollough, Cynthia H; Fletcher, Joel G
2014-01-01
To investigate whether the integrated circuit (IC) detector results in reduced noise in computed tomography (CT) colonography (CTC). Three hundred sixty-six consecutive patients underwent clinically indicated CTC using the same CT scanner system, except for a difference in CT detectors (IC or conventional). Image noise, patient size, and scanner radiation output (volume CT dose index) were quantitatively compared between patient cohorts using each detector system, with separate comparisons for the abdomen and pelvis. For the abdomen and pelvis, despite significantly larger patient sizes in the IC detector cohort (both P < 0.001), image noise was significantly lower (both P < 0.001), whereas volume CT dose index was unchanged (both P > 0.18). Based on the observed image noise reduction, radiation dose could alternatively be reduced by approximately 20% to result in similar levels of image noise. Computed tomography colonography images acquired using the IC detector had significantly lower noise than images acquired using the conventional detector. This noise reduction can permit further radiation dose reduction in CTC.
Graham, Anthony H D; Robbins, Jon; Bowen, Chris R; Taylor, John
2011-01-01
The adaptation of standard integrated circuit (IC) technology as a transducer in cell-based biosensors in drug discovery pharmacology, neural interface systems and electrophysiology requires electrodes that are electrochemically stable, biocompatible and affordable. Unfortunately, the ubiquitous Complementary Metal Oxide Semiconductor (CMOS) IC technology does not meet the first of these requirements. For devices intended only for research, modification of CMOS by post-processing using cleanroom facilities has been achieved. However, to enable adoption of CMOS as a basis for commercial biosensors, the economies of scale of CMOS fabrication must be maintained by using only low-cost post-processing techniques. This review highlights the methodologies employed in cell-based biosensor design where CMOS-based integrated circuits (ICs) form an integral part of the transducer system. Particular emphasis will be placed on the application of multi-electrode arrays for in vitro neuroscience applications. Identifying suitable IC packaging methods presents further significant challenges when considering specific applications. The various challenges and difficulties are reviewed and some potential solutions are presented.
The optical design of 3D ICs for smartphone and optro-electronics sensing module
NASA Astrophysics Data System (ADS)
Huang, Jiun-Woei
2018-03-01
Smartphone require limit space for image system, current lens, used in smartphones are refractive type, the effective focal length is limited the thickness of phone physical size. Other, such as optro-electronics sensing chips, proximity optical sensors, and UV indexer chips are integrated into smart phone with limit space. Due to the requirement of multiple lens in smartphone, proximity optical sensors, UV indexer and other optro-electronics sensing chips in a limited space of CPU board in future smart phone, optro-electronics 3D IC's integrated with optical lens or components may be a key technology for 3 C products. A design for reflective lens is fitted to CMOS, proximity optical sensors, UV indexer and other optro-electronics sensing chips based on 3-D IC. The reflective lens can be threes times of effective focal lens, and be able to resolve small object. The system will be assembled and integrated in one 3-D IC more easily.
Flexible packaging of solid-state integrated circuit chips with elastomeric microfluidics
Zhang, Bowei; Dong, Quan; Korman, Can E.; Li, Zhenyu; Zaghloul, Mona E.
2013-01-01
A flexible technology is proposed to integrate smart electronics and microfluidics all embedded in an elastomer package. The microfluidic channels are used to deliver both liquid samples and liquid metals to the integrated circuits (ICs). The liquid metals are used to realize electrical interconnects to the IC chip. This avoids the traditional IC packaging challenges, such as wire-bonding and flip-chip bonding, which are not compatible with current microfluidic technologies. As a demonstration we integrated a CMOS magnetic sensor chip and associate microfluidic channels on a polydimethylsiloxane (PDMS) substrate that allows precise delivery of small liquid samples to the sensor. Furthermore, the packaged system is fully functional under bending curvature radius of one centimetre and uniaxial strain of 15%. The flexible integration of solid-state ICs with microfluidics enables compact flexible electronic and lab-on-a-chip systems, which hold great potential for wearable health monitoring, point-of-care diagnostics and environmental sensing among many other applications.
Biogas production from anaerobic digestion of food waste and relevant air quality implications.
Kuo, Jeff; Dow, Jason
2017-09-01
Biopower can diversify energy supply and improve energy resiliency. Increases in biopower production from sustainable biomass can provide many economic and environmental benefits. For example, increasing biogas production through anaerobic digestion of food waste would increase the use of renewable fuels throughout California and add to its renewables portfolio. Although a biopower project will produce renewable energy, the process of producing bioenergy should harmonize with the goal of protecting public health. Meeting air emission requirements is paramount to the successful implementation of any biopower project. A case study was conducted by collecting field data from a wastewater treatment plant that employs anaerobic codigestion of fats, oils, and grease (FOG), food waste, and wastewater sludge, and also uses an internal combustion (IC) engine to generate biopower using the biogas. This research project generated scientific information on (a) quality and quantity of biogas from anaerobic codigestion of food waste and municipal wastewater sludge, (b) levels of contaminants in raw biogas that may affect beneficial uses of the biogas, (c) removal of the contaminants by the biogas conditioning systems, (d) emissions of NO x , SO 2 , CO, CO 2 , and methane, and (e) types and levels of air toxics present in the exhausts of the IC engine fueled by the biogas. The information is valuable to those who consider similar operations (i.e., co-digestion of food waste with municipal wastewater sludge and power generation using the produced biogas) and to support rulemaking decisions with regards to air quality issues for such applications. Full-scale operation of anaerobic codigestion of food waste with municipal sludge is viable, but it is still new. There is a lack of readily available scientific information on the quality of raw biogas, as well as on potential emissions from power generation using this biogas. This research developed scientific information with regard to quality and quantity of biogas from anaerobic co-digestion of food waste and municipal wastewater sludge, as well as impacts on air quality from biopower generation using this biogas. The need and performance of conditioning/pretreatment systems for biopower generation were also assessed.
System Modeling and Diagnostics for Liquefying-Fuel Hybrid Rockets
NASA Technical Reports Server (NTRS)
Poll, Scott; Iverson, David; Ou, Jeremy; Sanderfer, Dwight; Patterson-Hine, Ann
2003-01-01
A Hybrid Combustion Facility (HCF) was recently built at NASA Ames Research Center to study the combustion properties of a new fuel formulation that burns approximately three times faster than conventional hybrid fuels. Researchers at Ames working in the area of Integrated Vehicle Health Management recognized a good opportunity to apply IVHM techniques to a candidate technology for next generation launch systems. Five tools were selected to examine various IVHM techniques for the HCF. Three of the tools, TEAMS (Testability Engineering and Maintenance System), L2 (Livingstone2), and RODON, are model-based reasoning (or diagnostic) systems. Two other tools in this study, ICS (Interval Constraint Simulator) and IMS (Inductive Monitoring System) do not attempt to isolate the cause of the failure but may be used for fault detection. Models of varying scope and completeness were created, both qualitative and quantitative. In each of the models, the structure and behavior of the physical system are captured. In the qualitative models, the temporal aspects of the system behavior and the abstraction of sensor data are handled outside of the model and require the development of additional code. In the quantitative model, less extensive processing code is also necessary. Examples of fault diagnoses are given.
Low power, compact charge coupled device signal processing system
NASA Technical Reports Server (NTRS)
Bosshart, P. W.; Buss, D. D.; Eversole, W. L.; Hewes, C. R.; Mayer, D. J.
1980-01-01
A variety of charged coupled devices (CCDs) for performing programmable correlation for preprocessing environmental sensor data preparatory to its transmission to the ground were developed. A total of two separate ICs were developed and a third was evaluated. The first IC was a CCD chirp z transform IC capable of performing a 32 point DFT at frequencies to 1 MHz. All on chip circuitry operated as designed with the exception of the limited dynamic range caused by a fixed pattern noise due to interactions between the digital and analog circuits. The second IC developed was a 64 stage CCD analog/analog correlator for performing time domain correlation. Multiplier errors were found to be less than 1 percent at designed signal levels and less than 0.3 percent at the measured smaller levels. A prototype IC for performing time domain correlation was also evaluated.
Contaminant Mass Transfer During Boiling in Fractured Geologic Media
2011-04-01
on GC-ECD. Bromide was measured on a Dionex AS50 ion chromatography system equipped with a CD25 conductivity detector and a Dionex guard column...EDB Dibromethane EPICS Equilibrium Partitioning In Closed Systems FID Flame Ionized Detector GC Gas Chromatography IC Ion Chromatography ...International). Bromide was measured from filtered samples with a Dionex ion chromatograph (IC) with an AS11/AG11 column. The eluant for bromide
The Stirling engine as a low cost tool to educate mechanical engineers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gros, J.; Munoz, M.; Moreno, F.
1995-12-31
The University of Zaragoza through CIRCE, the New Enterprise foundation, an Opel foundation and the local Government of Aragon have been developed a program to introduce the Stirling Engine as a low cost tool to educate students in mechanical engineering. The promotion of a prize like GNAT Power organized by the magazine Model Engineer in London, has improved the practical education of students in the field of mechanical devices and thermal engines. Two editions of the contest, 1993 and 1994, awarded the greatest power Stirling engine made by only using a little candle of paraffin as a heat source. Fourmore » engines were presented in the first edition, with an average power of about 100 mW, and seven engines in the second one, achieving a power of about 230 mW. Presentations in Technical Schools and the University have been carried out. Also low cost tools have been made for measuring an electronic device to draw the real internal pressure volume diagram using a PC. A very didactic software to design classic kinematic alpha, beta and gamma engines plus Ringbom beta and gamma engines has been created. A book is going to be published (in Spanish) explaining the design of small Stirling engines as a way to start with low cost research in thermal engines, a very difficult target with IC engines.« less
NASA Astrophysics Data System (ADS)
Delvecchio, S.; Bonfiglio, P.; Pompoli, F.
2018-01-01
This paper deals with the state-of-the-art strategies and techniques based on vibro-acoustic signals that can monitor and diagnose malfunctions in Internal Combustion Engines (ICEs) under both test bench and vehicle operating conditions. Over recent years, several authors have summarized what is known in critical reviews mainly focused on reciprocating machines in general or on specific signal processing techniques: no attempts to deal with IC engine condition monitoring have been made. This paper first gives a brief summary of the generation of sound and vibration in ICEs in order to place further discussion on fault vibro-acoustic diagnosis in context. An overview of the monitoring and diagnostic techniques described in literature using both vibration and acoustic signals is also provided. Different faulty conditions are described which affect combustion, mechanics and the aerodynamics of ICEs. The importance of measuring acoustic signals, as opposed to vibration signals, is due since the former seem to be more suitable for implementation on on-board monitoring systems in view of their non-intrusive behaviour, capability in simultaneously capturing signatures from several mechanical components and because of the possibility of detecting faults affecting airborne transmission paths. In view of the recent needs of the industry to (-) optimize component structural durability adopting long-life cycles, (-) verify the engine final status at the end of the assembly line and (-) reduce the maintenance costs monitoring the ICE life during vehicle operations, monitoring and diagnosing system requests are continuously growing up. The present review can be considered a useful guideline for test engineers in understanding which types of fault can be diagnosed by using vibro-acoustic signals in sufficient time in both test bench and operating conditions and which transducer and signal processing technique (of which the essential background theory is here reported) could be considered the most reliable and informative to be implemented for the fault in question.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yanfeng; Gao, Xiaoli; Michael Garavito, R., E-mail: garavito@msu.edu
2011-04-22
Highlights: {yields} Crystal structure of the intracellular domain of (pro)renin receptor (PRR-IC) as MBP fusion protein at 2.0 A (maltose-free) and 2.15 A (maltose-bound). {yields} MBP fusion protein is a dimer in crystals in the presence and absence of maltose. {yields} PRR-IC domain is responsible for the dimerization of the fusion protein. {yields} Residues in the PRR-IC domain, particularly two tyrosines, dominate the intermolecular interactions, suggesting a role for the PRR-IC domain in PRR dimerization. -- Abstract: The (pro)renin receptor (PRR) is an important component of the renin-angiotensin system (RAS), which regulates blood pressure and cardiovascular function. The integral membranemore » protein PRR contains a large extracellular domain ({approx}310 amino acids), a single transmembrane domain ({approx}20 amino acids) and an intracellular domain ({approx}19 amino acids). Although short, the intracellular (IC) domain of the PRR has functionally important roles in a number of signal transduction pathways activated by (pro)renin binding. Meanwhile, together with the transmembrane domain and a small portion of the extracellular domain ({approx}30 amino acids), the IC domain is also involved in assembly of V{sub 0} portion of the vacuolar proton-translocating ATPase (V-ATPase). To better understand structural and multifunctional roles of the PRR-IC, we report the crystal structure of the PRR-IC domain as maltose-binding protein (MBP) fusion proteins at 2.0 A (maltose-free) and 2.15 A (maltose-bound). In the two separate crystal forms having significantly different unit-cell dimensions and molecular packing, MBP-PRR-IC fusion protein was found to be a dimer, which is different with the natural monomer of native MBP. The PRR-IC domain appears as a relatively flexible loop and is responsible for the dimerization of MBP fusion protein. Residues in the PRR-IC domain, particularly two tyrosines, dominate the intermonomer interactions, suggesting a role for the PRR-IC domain in protein oligomerization.« less
Choice of Tuning Parameters on 3D IC Engine Simulations Using G-Equation
Liu, Jinlong; Szybist, James; Dumitrescu, Cosmin
2018-04-03
3D CFD spark-ignition IC engine simulations are extremely complex for the regular user. Truly-predictive CFD simulations for the turbulent flame combustion that solve fully coupled transport/chemistry equations may require large computational capabilities unavailable to regular CFD users. A solution is to use a simpler phenomenological model such as the G-equation that decouples transport/chemistry result. Such simulation can still provide acceptable and faster results at the expense of predictive capabilities. While the G-equation is well understood within the experienced modeling community, the goal of this paper is to document some of them for a novice or less experienced CFD user whomore » may not be aware that phenomenological models of turbulent flame combustion usually require heavy tuning and calibration from the user to mimic experimental observations. This study used ANSYS® Forte, Version 17.2, and the built-in G-equation model, to investigate two tuning constants that influence flame propagation in 3D CFD SI engine simulations: the stretch factor coefficient, Cms and the flame development coefficient, Cm2. After identifying several Cm2-Cms pairs that matched experimental data at one operating conditions, simulation results showed that engine models that used different Cm2-Cms sets predicted similar combustion performance, when the spark timing, engine load, and engine speed were changed from the operating condition used to validate the CFD simulation. A dramatic shift was observed when engine speed was doubled, which suggested that the flame stretch coefficient, Cms, had a much larger influence at higher engine speeds compared to the flame development coefficient, Cm2. Therefore, the Cm2-Cms sets that predicted a higher turbulent flame under higher in-cylinder pressure and temperature increased the peak pressure and efficiency. This suggest that the choice of the Cm2-Cms will affect the G-equation-based simulation accuracy when engine speed increases from the one used to validate the model. As a result, for the less-experienced CFD user and in the absence of enough experimental data that would help retune the tuning parameters at various operating conditions, the purpose of a good G-equation-based 3D engine simulation is to guide and/or complement experimental investigations, not the other way around. Only a truly-predictive simulation that fully couples the turbulence/chemistry equations can help reduce the amount of experimental work.« less
Choice of Tuning Parameters on 3D IC Engine Simulations Using G-Equation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Jinlong; Szybist, James; Dumitrescu, Cosmin
3D CFD spark-ignition IC engine simulations are extremely complex for the regular user. Truly-predictive CFD simulations for the turbulent flame combustion that solve fully coupled transport/chemistry equations may require large computational capabilities unavailable to regular CFD users. A solution is to use a simpler phenomenological model such as the G-equation that decouples transport/chemistry result. Such simulation can still provide acceptable and faster results at the expense of predictive capabilities. While the G-equation is well understood within the experienced modeling community, the goal of this paper is to document some of them for a novice or less experienced CFD user whomore » may not be aware that phenomenological models of turbulent flame combustion usually require heavy tuning and calibration from the user to mimic experimental observations. This study used ANSYS® Forte, Version 17.2, and the built-in G-equation model, to investigate two tuning constants that influence flame propagation in 3D CFD SI engine simulations: the stretch factor coefficient, Cms and the flame development coefficient, Cm2. After identifying several Cm2-Cms pairs that matched experimental data at one operating conditions, simulation results showed that engine models that used different Cm2-Cms sets predicted similar combustion performance, when the spark timing, engine load, and engine speed were changed from the operating condition used to validate the CFD simulation. A dramatic shift was observed when engine speed was doubled, which suggested that the flame stretch coefficient, Cms, had a much larger influence at higher engine speeds compared to the flame development coefficient, Cm2. Therefore, the Cm2-Cms sets that predicted a higher turbulent flame under higher in-cylinder pressure and temperature increased the peak pressure and efficiency. This suggest that the choice of the Cm2-Cms will affect the G-equation-based simulation accuracy when engine speed increases from the one used to validate the model. As a result, for the less-experienced CFD user and in the absence of enough experimental data that would help retune the tuning parameters at various operating conditions, the purpose of a good G-equation-based 3D engine simulation is to guide and/or complement experimental investigations, not the other way around. Only a truly-predictive simulation that fully couples the turbulence/chemistry equations can help reduce the amount of experimental work.« less
A procedure for radiometric recalibration of Landsat 5 TM reflective-band data
Chander, G.; Haque, M.O.; Micijevic, E.; Barsi, J.A.
2010-01-01
From the Landsat program's inception in 1972 to the present, the Earth science user community has been benefiting from a historical record of remotely sensed data. The multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provide the backbone for this extensive archive. Historically, the radiometric calibration procedure for the L5 TM imagery used the detectors' response to the internal calibrator (IC) on a scene-by-scene basis to determine the gain and offset for each detector. The IC system degraded with time, causing radiometric calibration errors up to 20%. In May 2003, the L5 TM data processed and distributed by the U.S. Geological Survey (USGS) Earth Resources Observation and Science Center through the National Landsat Archive Production System (NLAPS) were updated to use a lifetime lookup-table (LUT) gain model to radiometrically calibrate TM data instead of using scene-specific IC gains. Further modification of the gain model was performed in 2007. The L5 TM data processed using IC prior to the calibration update do not benefit from the recent calibration revisions. A procedure has been developed to give users the ability to recalibrate their existing level-1 products. The best recalibration results are obtained if the work-order report that was included in the original standard data product delivery is available. However, if users do not have the original work-order report, the IC trends can be used for recalibration. The IC trends were generated using the radiometric gain trends recorded in the NLAPS database. This paper provides the details of the recalibration procedure for the following: 1) data processed using IC where users have the work-order file; 2) data processed using IC where users do not have the work-order file; 3) data processed using prelaunch calibration parameters; and 4) data processed using the previous version of the LUT (e.g., LUT03) that was released before April 2, 2007.
Gao, Zhouzheng; Zhang, Hongping; Ge, Maorong; Niu, Xiaoji; Shen, Wenbin; Wickert, Jens; Schuh, Harald
2015-01-01
The continuity and reliability of precise GNSS positioning can be seriously limited by severe user observation environments. The Inertial Navigation System (INS) can overcome such drawbacks, but its performance is clearly restricted by INS sensor errors over time. Accordingly, the tightly coupled integration of GPS and INS can overcome the disadvantages of each individual system and together form a new navigation system with a higher accuracy, reliability and availability. Recently, ionosphere-constrained (IC) precise point positioning (PPP) utilizing raw GPS observations was proven able to improve both the convergence and positioning accuracy of the conventional PPP using ionosphere-free combined observations (LC-PPP). In this paper, a new mode of tightly coupled integration, in which the IC-PPP instead of LC-PPP is employed, is implemented to further improve the performance of the coupled system. We present the detailed mathematical model and the related algorithm of the new integration of IC-PPP and INS. To evaluate the performance of the new tightly coupled integration, data of both airborne and vehicle experiments with a geodetic GPS receiver and tactical grade inertial measurement unit are processed and the results are analyzed. The statistics show that the new approach can further improve the positioning accuracy compared with both IC-PPP and the tightly coupled integration of the conventional PPP and INS. PMID:25763647
TDR method for determine IC's parameters
NASA Astrophysics Data System (ADS)
Timoshenkov, V.; Rodionov, D.; Khlybov, A.
2016-12-01
Frequency domain simulation is a widely used approach for determine integrated circuits parameters. This approach can be found in most of software tools used in IC industry. Time domain simulation approach shows intensive usage last years due to some advantages. In particular it applicable for analysis of nonlinear and nonstationary systems where frequency domain is inapplicable. Resolution of time domain systems allow see heterogeneities on distance 1mm, determine it parameters and properties. Authors used approach based on detecting reflected signals from heterogeneities - time domain reflectometry (TDR). Field effect transistor technology scaling up to 30-60nm gate length and 10nm gate dielectric, heterojunction bi-polar transistors with 10-30nm base width allows fabricate digital IC's with 20GHz clock frequency and RF-IC's with tens GHz bandwidth. Such devices and operation speed suppose transit signal by use microwave lines. There are local heterogeneities can be found inside of the signal path due to connections between different parts of signal lines (stripe line-RF-connector pin, stripe line - IC package pin). These heterogeneities distort signals that cause bandwidth decrease for RF-devices. Time domain research methods of transmission and reflected signals give the opportunities to determine heterogeneities, it properties, parameters and built up equivalent circuits. Experimental results are provided and show possibility for inductance and capacitance measurement up to 25GHz. Measurements contains result of signal path research on IC and printed circuit board (PCB) used for 12GHz RF chips. Also dielectric constant versus frequency was measured up to 35GHz.
"Kill" the messenger: Targeting of cell-derived microparticles in lupus nephritis.
Nielsen, Christoffer T; Rasmussen, Niclas S; Heegaard, Niels H H; Jacobsen, Søren
2016-07-01
Immune complex (IC) deposition in the glomerular basement membrane (GBM) is a key early pathogenic event in lupus nephritis (LN). The clarification of the mechanisms behind IC deposition will enable targeted therapy in the future. Circulating cell-derived microparticles (MPs) have been proposed as major sources of extracellular autoantigens and ICs and triggers of autoimmunity in LN. The overabundance of galectin-3-binding protein (G3BP) along with immunoglobulins and a few other proteins specifically distinguish circulating MPs in patients with systemic lupus erythematosus (SLE), and this is most pronounced in patients with active LN. G3BP co-localizes with deposited ICs in renal biopsies from LN patients supporting a significant presence of MPs in the IC deposits. G3BP binds strongly to glomerular basement membrane proteins and integrins. Accordingly, MP surface proteins, especially G3BP, may be essential for the deposition of ICs in kidneys and thus for the ensuing formation of MP-derived electron dense structures in the GBM, and immune activation in LN. This review focuses on the notion of targeting surface molecules on MPs as an entirely novel treatment strategy in LN. By targeting MPs, a double hit may be achieved by attenuating both the autoantigenic fueling of immune complexes and the triggering of the adaptive immune system. Thereby, early pathogenic events may be blocked in contrast to current treatment strategies that primarily target and modulate later events in the cellular and humoral immune response. Copyright © 2016 Elsevier B.V. All rights reserved.
Preclinical evaluation of a novel cyanine dye for tumor imaging with in vivo photoacoustic imaging.
Temma, Takashi; Onoe, Satoru; Kanazaki, Kengo; Ono, Masahiro; Saji, Hideo
2014-09-01
Photoacoustic imaging (PA imaging or PAI) has shown great promise in the detection and monitoring of cancer. Although nanocarrier-based contrast agents have been studied for use in PAI, small molecule contrast agents are required due to their ease of preparation, costeffectiveness, and low toxicity. Here, we evaluated the usefulness of a novel cyanine dye IC7-1-Bu as a PAI contrast agent without conjugated targeting moieties for in vivo tumor imaging in a mice model. Basic PA characteristics of IC7-1-Bu were compared with indocyanine green (ICG), a Food and Drug Administration approved dye, in an aqueous solution. We evaluated the tumor accumulation profile of IC7-1-Bu and ICG by in vivo fluorescence imaging. In vivo PAI was then performed with a photoacoustic tomography system 24 and 48 h after intravenous injection of IC7-1-Bu into tumor bearing mice. IC7-1-Bu showed about a 2.3-fold higher PA signal in aqueous solution compared with that of ICG. Unlike ICG, IC7-1-Bu showed high tumor fluorescence after intravenous injection. In vivo PAI provided a tumor to background PA signal ratio of approximately 2.5 after intravenous injection of IC7-1-Bu. These results indicate that IC7-1-Bu is a promising PAI contrast agent for cancer imaging without conjugation of targeting moieties.
Insertion of GaAs MMICs into EW systems
NASA Astrophysics Data System (ADS)
Schineller, E. R.; Pospishil, A.; Grzyb, J.
1989-09-01
Development activities on a microwave/mm-wave monolithic IC (MIMIC) program are described, as well as the methodology for inserting these GaAs IC chips into several EW systems. The generic EW chip set developed on the MIMIC program consists of 23 broadband chip types, including amplifiers, oscillators, mixers, switches, variable attenuators, power dividers, and power combiners. These chips are being designed for fabrication using the multifunction self-aligned gate process. The benefits from GaAs IC insertion are quantified by a comparison of hardware units fabricated with existing MIC and digital ECL technology and the same units manufactured with monolithic technology. It is found that major improvements in cost, reliability, size, weight, and performance can be realized. Examples illustrating the methodology for technology insertion are presented.
Berntsen, Gro; Høyem, Audhild; Lettrem, Idar; Ruland, Cornelia; Rumpsfeld, Markus; Gammon, Deede
2018-06-20
Person-Centered Integrated Care (PC-IC) is believed to improve outcomes and experience for persons with multiple long-term and complex conditions. No broad consensus exists regarding how to capture the patient-experienced quality of PC-IC. Most PC-IC evaluation tools focus on care events or care in general. Building on others' and our previous work, we outlined a 4-stage goal-oriented PC-IC process ideal: 1) Personalized goal setting 2) Care planning aligned with goals 3) Care delivery according to plan, and 4) Evaluation of goal attainment. We aimed to explore, apply, refine and operationalize this quality of care framework. This paper is a qualitative evaluative review of the individual Patient Pathways (iPP) experiences of 19 strategically chosen persons with multimorbidity in light of ideals for chronic care. The iPP includes all care events, addressing the persons collected health issues, organized by time. We constructed iPPs based on the electronic health record (from general practice, nursing services, and hospital) with patient follow-up interviews. The application of the framework and its refinement were parallel processes. Both were based on analysis of salient themes in the empirical material in light of the PC-IC process ideal and progressively more informed applications of themes and questions. The informants consistently reviewed care quality by how care supported/ threatened their long-term goals. Personal goals were either implicit or identified by "What matters to you?" Informants expected care to address their long-term goals and placed responsibility for care quality and delivery at the system level. The PC-IC process framework exposed system failure in identifying long-term goals, provision of shared long-term multimorbidity care plans, monitoring of care delivery and goal evaluation. The PC-IC framework includes descriptions of ideal care, key questions and literature references for each stage of the PC-IC process. This first version of a PC-IC process framework needs further validation in other settings. Gaps in care that are invisible with event-based quality of care frameworks become apparent when evaluated by a long-term goal-driven PC-IC process framework. The framework appears meaningful to persons with multimorbidity.
2nd International Conference on Rheology and Modeling of Materials (IC-RMM2)
NASA Astrophysics Data System (ADS)
2017-01-01
Understanding the rheological properties of materials and their rheological behaviors during their manufacturing processes and in their applications in many cases can help to increase the efficiency and competitiveness not only of the finished goods and products but the organizations and societies also. The more scientific supported and prepared organizations develop more competitive products with better thermal, mechanical, physical, chemical and biological properties and the leading companies apply more competitive equipment and technology processes. The aims of the 2nd International Conference on Rheology and Modeling of Materials (ic-rmm2) and the parallel organized symposiums of the 1st International Symposium on Powder Injection Molding (is-pim1) and the 1st International Symposium on Rheology and Fracture of Solids (is-rfs1) are the followings: Promote new methods and results of scientific research in the fields of modeling and measurements of rheological properties and behavior of materials under processing and applications; Change information between the theoretical and applied sciences as well as technical and technological implantations. Promote the communication and collaboration between the scientists, researchers and engineers of different disciplines, different nations, countries and continents. The international conference ic-rmm2 and symposiums of is-pim1 and is-rfs1 provide a platform among the leading international scientists, researchers, PhD students and engineers for discussing recent achievements in measurement, modeling and application of rheology in materials technology and materials science of liquids, melts, solids, crystals and amorphous structures. Among thr major fields of interest are the influence of materials structures, mechanical stresses, temperatures, deformation speeds and shear rates on rheological and physical properties, phase transformation of foams, foods, polymers, plastics and other competitive materials like ceramics, nanomaterials, medical- and biomaterials, cosmetics, coatings, light metals, alloys, glasses, films, composites, hetero-modulus, hetero-viscous, hetero-plastic complex materials, petrochemicals and hybrid materials. Multidisciplinary applications of rheology and rheological modeling in material science and technology encountered in sectors like alloys, ceramics, glasses, thin films, polymers, clays, construction materials, energy, aerospace, automotive and marine industry. Rheology in food, chemistry, medicine, biosciences and environmental sciences are of particular interests. In accordance to the program of the conference ic-rmm2 and symposiums is-pim1 and isrfs1 we have received more than 250 inquires and registrations from different organizations. Finally more than 240 abstracts were accepted for presentation. From them 12 were PLENARY lectures and 112 ORAL presentation. Researchers from 41 countries of Asia, Europe, Africa, North and South America arrived to Miskolc-Lillafüred (Hungary) and participated in the events of the conference. Including co-authors, the research work of more than 700 scientists were presented in the SESSIONS and SYMPOSIUMS of ic-rmm2 conference. Prof. Dr. László A. Gömze chair, ic-rmm2
Interdisciplinary collaboration: the role of the clinical nurse leader.
Bender, Miriam; Connelly, Cynthia D; Brown, Caroline
2013-01-01
To explore the feasibility and acceptability of a clinical nurse leader (CNL) role to improve interdisciplinary collaboration (IC) within a fragmented acute-care microsystem. Fragmented patient care is associated with preventable adverse healthcare outcomes. IC decreases fragmentation and improves patient care quality. The CNL role is theorized to provide the necessary leadership and competency skill base to impact IC at the optimal organizational level, the point of care where most healthcare decisions are made. This study used a descriptive non-experimental design. CNL daily workflow was developed to target empirical determinants of IC. Descriptive data were collected from multiple stakeholders using an investigator-developed survey. Findings indicate the integration of the role is feasible and acceptable to the microsystem healthcare team. Preliminary evidence suggests the CNL role may be an effective intervention to facilitate IC. More research is needed to support the CNL role's association with microsystem IC. The CNL role presents an innovative opportunity for clinical and administrative leadership to partner together to redesign a healthcare delivery system and improve patient care quality. © 2012 Blackwell Publishing Ltd.
Selective NOx Recirculation for Stationary Lean-Burn Natural Gas Engines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nigel N. Clark
Nitric oxide (NO) and nitrogen dioxide (NO2) generated by internal combustion (IC) engines are implicated in adverse environmental and health effects. Even though lean-burn natural gas engines have traditionally emitted lower oxides of nitrogen (NOx) emissions compared to their diesel counterparts, natural gas engines are being further challenged to reduce NOx emissions to 0.1 g/bhp-hr. The Selective NOx Recirculation (SNR) approach for NOx reduction involves cooling the engine exhaust gas and then adsorbing the NOx from the exhaust stream, followed by the periodic desorption of NOx. By sending the desorbed NOx back into the intake and through the engine, amore » percentage of the NOx can be decomposed during the combustion process. SNR technology has the support of the Department of Energy (DOE), under the Advanced Reciprocating Engine Systems (ARES) program to reduce NOx emissions to under 0.1 g/bhp-hr from stationary natural gas engines by 2010. The NO decomposition phenomenon was studied using two Cummins L10G natural gas fueled spark-ignited (SI) engines in three experimental campaigns. It was observed that the air/fuel ratio ({lambda}), injected NO quantity, added exhaust gas recirculation (EGR) percentage, and engine operating points affected NOx decomposition rates within the engine. Chemical kinetic model predictions using the software package CHEMKIN were performed to relate the experimental data with established rate and equilibrium models. The model was used to predict NO decomposition during lean-burn, stoichiometric burn, and slightly rich-burn cases with added EGR. NOx decomposition rates were estimated from the model to be from 35 to 42% for the lean-burn cases and from 50 to 70% for the rich-burn cases. The modeling results provided an insight as to how to maximize NOx decomposition rates for the experimental engine. Results from this experiment along with chemical kinetic modeling solutions prompted the investigation of rich-burn operating conditions, with added EGR to prevent preignition. It was observed that the relative air/fuel ratio, injected NO quantity, added EGR fraction, and engine operating points affected the NO decomposition rates. While operating under these modified conditions, the highest NO decomposition rate of 92% was observed. In-cylinder pressure data gathered during the experiments showed minimum deviation from peak pressure as a result of NO injections into the engine. A NOx adsorption system, from Sorbent Technologies, Inc., was integrated with the Cummins engine, comprised a NOx adsorbent chamber, heat exchanger, demister, and a hot air blower. Data were gathered to show the possibility of NOx adsorption from the engine exhaust, and desorption of NOx from the sorbent material. In order to quantify the NOx adsorption/desorption characteristics of the sorbent material, a benchtop adsorption system was constructed. The temperature of this apparatus was controlled while data were gathered on the characteristics of the sorbent material for development of a system model. A simplified linear driving force model was developed to predict NOx adsorption into the sorbent material as cooled exhaust passed over fresh sorbent material. A mass heat transfer analysis was conducted to analyze the possibility of using hot exhaust gas for the desorption process. It was found in the adsorption studies, and through literature review, that NO adsorption was poor when the carrier gas was nitrogen, but that NO in the presence of oxygen was adsorbed at levels exceeding 1% by mass of the sorbent. From the three experimental campaigns, chemical kinetic modeling analysis, and the scaled benchtop NOx adsorption system, an overall SNR system model was developed. An economic analysis was completed, and showed that the system was impractical in cost for small engines, but that economies of scale favored the technology.« less
Abousaad, S; Lassiter, K; Piekarski, A; Chary, P; Striplin, K; Christensen, K; Bielke, L R; Hargis, B M; Dridi, S; Bottje, W G
2017-05-01
Studies were conducted using a commercial InovojectTM system to determine effects of in ovo feeding of dextrin and iodinated casein (IC) on hatch and posthatch growth in broilers. At ∼18.5 d embryonic development, eggs were treated with 0, 240, or 480 μg IC/mL in saline (Cont, IC240, and IC480) or dextrin (Dext, DextIC240 and DextIC480). The Dext solution consisted of 18% maltodextrin and 10% potato starch dextrin; saline was the vehicle used by the company for in ovo vaccination. The volume for all in ovo treatments was 50 μL/injection. Eggs in Experiment 1 were transferred to a commercial hatcher unit whereas eggs in Experiments 2 and 3 were transferred to a research hatcher unit to assess effects of treatments on timing of hatch. At hatch, chicks were randomly selected and placed in floor pens and grown to 6 wk. In Experiment 1, there were no differences in hatch weights, but broilers provided Dext IC240 in ovo were heavier (P < 0.05) at 6 wk compared to other treatments with the exception of the Dext IC240 group. In Experiment 2, hatch weights were heavier (P < 0.05) in chicks receiving IC240 and DexIC480 treatments compared to Controls. At 6 wk, broilers in all treatments were heavier (P < 0.05) than Cont with the exception of IC480. In Experiment 3, hatch was stimulated by IC240 (in saline), but was delayed by Dext IC240. Serum analysis of β-hydroxybutyrate (μM/mL), as an indicator of ketone accumulation from fat metabolism of chicks held in chick boxes for 24 h posthatch (to simulate delay in placement after hatch), indicated that chicks in the IC240 group (that hatched earlier) had higher blood ketones compared to chicks that received Dext or DextIC240 in ovo (that hatched later). We conclude dextrin and iodinated casein (240 μg/mL) provided in ovo (∼18.5 d of embryonic development) has the potential to improve chick quality and posthatch body weight by delaying or narrowing hatch window. © 2016 Poultry Science Association Inc.
NASA Technical Reports Server (NTRS)
2011-01-01
NASA is interested in developing technology that leads to more routine, safe, and affordable access to space. Access to space using airbreathing propulsion systems has potential to meet these objectives based on Airbreathing Access to Space (AAS) system studies. To this end, the NASA Fundamental Aeronautics Program (FAP) Hypersonic Project is conducting fundamental research on a Turbine Based Combined Cycle (TBCC) propulsion system. The TBCC being studied considers a dual flow-path inlet system. One flow-path includes variable geometry to regulate airflow to a turbine engine cycle. The turbine cycle provides propulsion from take-off to supersonic flight. The second flow-path supports a dual-mode scramjet (DMSJ) cycle which would be initiated at supersonic speed to further accelerate the vehicle to hypersonic speed. For a TBCC propulsion system to accelerate a vehicle from supersonic to hypersonic speed, a critical enabling technology is the ability to safely and effectively transition from the turbine to the DMSJ-referred to as mode transition. To experimentally test methods of mode transition, a Combined Cycle Engine (CCE) Large-scale Inlet testbed was designed with two flow paths-a low speed flow-path sized for a turbine cycle and a high speed flow-path designed for a DMSJ. This testbed system is identified as the CCE Large-Scale Inlet for Mode Transition studies (CCE-LIMX). The test plan for the CCE-LIMX in the NASA Glenn Research Center (GRC) 10- by 10-ft Supersonic Wind Tunnel (10x10 SWT) is segmented into multiple phases. The first phase is a matrix of inlet characterization (IC) tests to evaluate the inlet performance and establish the mode transition schedule. The second phase is a matrix of dynamic system identification (SysID) experiments designed to support closed-loop control development at mode transition schedule operating points for the CCE-LIMX. The third phase includes a direct demonstration of controlled mode transition using a closed loop control system developed with the data obtained from the first two phases. Plans for a fourth phase include mode transition experiments with a turbine engine. This paper, focusing on the first two phases of experiments, presents developed operational and analysis tools for streamlined testing and data reduction procedures.
Butt, Taimur S; Koutlakis-Barron, Irene; AlJumaah, Suliman; AlThawadi, Sahar; AlMofada, Saleh
2016-05-01
Transmission of Middle East respiratory syndrome-coronavirus (MERS-CoV) among health care workers (HCWs) and patients has been documented with mortality rate approximating 36%. We propose advanced infection control measures (A-IC) used in conjunction with basic infection control measures (B-IC) help reduce pathogen transmission. B-IC include standard and transmission-based precautions. A-IC are initiatives implemented within our center to enhance effectiveness of B-IC. Study effectiveness of combining B-IC and A-IC to prevent transmission of MERS-CoV to HCWs. A retrospective observational study was undertaken. A-IC measures include administrative support with daily rounds; infection control risk assessment; timely screening, isolation, and specimen analysis; collaboration; epidemic planning; stockpiling; implementation of contingency plans; full personal protective equipment use for advanced airway management; use of a real-time electronic isolation flagging system; infection prevention and control team on-call protocols; pretransfer MERS-CoV testing; and education. A total of 874 real-time polymerase chain reaction MERS-CoV tests were performed during the period beginning July 1, 2013, and ending January 31, 2015. Six hundred ninety-four non-HCWs were tested, of these 16 tested positive for MERS-CoV and their infection was community acquired. Sixty-nine percent of the confirmed MERS-CoV-positive cases were men, with an average age of 56 years (range, 19-84 years). Of the total tested for MERS-CoV, 180 individuals were HCWs with zero positivity. Adhering to a combination of B-IC and A-IC reduces the risk of MERS-CoV transmission to HCWs. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Chung, Shiu-Dong; Liu, Shih-Ping; Li, Hsien-Chang; Lin, Herng-Ching
2014-01-01
This study aims to investigate the differences in the utilization of healthcare services between patients with bladder pain syndrome/interstitial cystitis (BPS/IC) and patients without using a population-based database in Taiwan. This study comprised of 350 patients with BPS/IC and 1,750 age-matched controls. Healthcare resource utilization was evaluated in the one-year follow-up period as follows: number of outpatient visits and inpatient days, and the mean costs of outpatient and inpatient treatment. A multivariate regression analysis was used to evaluate the relationship between BPS/IC and total costs of health care services. For urological services, patients with BPS/IC had a significantly higher number of outpatient visits (2.5 vs. 0.2, p<0.001) as well as significantly higher outpatient costs ($US166 vs. $US6.8, p<0.001) than the controls. For non-urologic services, patients with BPS/IC had a significantly high number of outpatient visits (35.0 vs. 21.3, p<0.001) as well as significantly higher outpatient cots ($US912 vs. $US675, p<0.001) as compared to the controls. Overall, patients with BPS/IC had 174% more outpatient visits and 150% higher total costs than the controls. Multiple-regression-analyses also showed that the patients with BPS/IC had significantly higher total costs for all healthcare services than the controls. This study found that patients with BPS/IC have a significantly higher number of healthcare related visits, and have significantly higher healthcare related costs than age-matched controls. The high level of healthcare services utilization accrued with BPS/IC was not necessarily exclusive for BPS/IC, but may have also been associated with medical co-morbidities.
De Martino, Federico; Gentile, Francesco; Esposito, Fabrizio; Balsi, Marco; Di Salle, Francesco; Goebel, Rainer; Formisano, Elia
2007-01-01
We present a general method for the classification of independent components (ICs) extracted from functional MRI (fMRI) data sets. The method consists of two steps. In the first step, each fMRI-IC is associated with an IC-fingerprint, i.e., a representation of the component in a multidimensional space of parameters. These parameters are post hoc estimates of global properties of the ICs and are largely independent of a specific experimental design and stimulus timing. In the second step a machine learning algorithm automatically separates the IC-fingerprints into six general classes after preliminary training performed on a small subset of expert-labeled components. We illustrate this approach in a multisubject fMRI study employing visual structure-from-motion stimuli encoding faces and control random shapes. We show that: (1) IC-fingerprints are a valuable tool for the inspection, characterization and selection of fMRI-ICs and (2) automatic classifications of fMRI-ICs in new subjects present a high correspondence with those obtained by expert visual inspection of the components. Importantly, our classification procedure highlights several neurophysiologically interesting processes. The most intriguing of which is reflected, with high intra- and inter-subject reproducibility, in one IC exhibiting a transiently task-related activation in the 'face' region of the primary sensorimotor cortex. This suggests that in addition to or as part of the mirror system, somatotopic regions of the sensorimotor cortex are involved in disambiguating the perception of a moving body part. Finally, we show that the same classification algorithm can be successfully applied, without re-training, to fMRI collected using acquisition parameters, stimulation modality and timing considerably different from those used for training.
Beaumont, Eric; Salavatian, Siamak; Southerland, E Marie; Vinet, Alain; Jacquemet, Vincent; Armour, J Andrew; Ardell, Jeffrey L
2013-01-01
The aims of the study were to determine how aggregates of intrinsic cardiac (IC) neurons transduce the cardiovascular milieu versus responding to changes in central neuronal drive and to determine IC network interactions subsequent to induced neural imbalances in the genesis of atrial fibrillation (AF). Activity from multiple IC neurons in the right atrial ganglionated plexus was recorded in eight anaesthetized canines using a 16-channel linear microelectrode array. Induced changes in IC neuronal activity were evaluated in response to: (1) focal cardiac mechanical distortion; (2) electrical activation of cervical vagi or stellate ganglia; (3) occlusion of the inferior vena cava or thoracic aorta; (4) transient ventricular ischaemia, and (5) neurally induced AF. Low level activity (ranging from 0 to 2.7 Hz) generated by 92 neurons was identified in basal states, activities that displayed functional interconnectivity. The majority (56%) of IC neurons so identified received indirect central inputs (vagus alone: 25%; stellate ganglion alone: 27%; both: 48%). Fifty per cent transduced the cardiac milieu responding to multimodal stressors applied to the great vessels or heart. Fifty per cent of IC neurons exhibited cardiac cycle periodicity, with activity occurring primarily in late diastole into isovolumetric contraction. Cardiac-related activity in IC neurons was primarily related to direct cardiac mechano-sensory inputs and indirect autonomic efferent inputs. In response to mediastinal nerve stimulation, most IC neurons became excessively activated; such network behaviour preceded and persisted throughout AF. It was concluded that stochastic interactions occur among IC local circuit neuronal populations in the control of regional cardiac function. Modulation of IC local circuit neuronal recruitment may represent a novel approach for the treatment of cardiac disease, including atrial arrhythmias. PMID:23818689
1964-10-01
This photograph depicts a forward skirt being placed on the liquid oxygen tank for Saturn V S-IC (first) stage in the Manufacturing Engineering Laboratory at the Marshall Space Flight Center. Thirty-three feet in diameter, the fuel tanks hold a total of 4,400,000 pounds of fuel. Although this tankage was assembled at MSFC, the elements were made by the Boeing Company at Wichita and the Michoud Operations at New Orleans.
Sheng, Rong; Xu, Xianxiang; Tang, Qin; Bian, Difei; Li, Ying; Qian, Cheng; He, Xin; Gao, Xinghua; Pan, Rong; Wang, Chong; Luo, Yubin; Xia, Yufeng; Dai, Yue
2011-01-01
Radix Pseudostellariae is used as a tonic drug in traditional Chinese medicine with immunomodulating and anti-fatigue activities, and the polysaccharide is considered as the main active component. The purpose of this study is to examine the effect of the polysaccharide isolated from Radix Pseudostellariae (PRP) on mouse chronic fatigue syndrome (CFS) induced by intraperitoneal injection of polyriboinosinic:polyribocytidylic acid (poly I:C), a double-stranded synthetic RNA. It has shown that the fatigue symptom of mice lasted at least 1 week as evaluated by forced swimming time. PRP (100, 200, 400 mg kg(-1)), orally administered 3 days before poly I:C injection, showed dose-dependent anti-fatigue effects. In addition, poly I:C led to evident alternations in neuroendocrine and immune systems of mice, such as reduced spontaneous activity and learning ability, declined serum level of corticosterone, increased weight indexes and T lymphocyte numbers in thymuses and spleens, and increased CD4(+)/CD8(+) ratio but decreased proliferation ability of T lymphocytes in spleens. PRP alleviated the abnormalities caused by poly I:C, and restored the function of hosts to normal conditions. The findings suggest that PRP is beneficial to CFS, and the underlying mechanisms of action involve neuroendocrine and immune systems.
Analog Techniques in CEBAF's RF Control System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hovater, J.; Fugitt, Jock
1988-01-01
Recent developments in high-speed analog technology have progressed into the areas of traditional RF technology.Diode-related devices are being replaced by analog IC's in the CEBAF RF control system.Complex phase modulators and attenuators have been successfully tested at 70 MHz.They have three advantages over existing technology: lower cost, less temperature sensitivity, and more linearity.RF signal conditioning components and how to implement the new analog IC's will be covered in this paper.
ICT Proficiency and Gender: A Validation on Training and Development
ERIC Educational Resources Information Center
Lin, Shinyi; Shih, Tse-Hua; Lu, Ruiling
2013-01-01
Use of innovative learning/instruction mode, embedded in the Certification Pathway System (CPS) developed by Certiport TM, is geared toward Internet and Computing Benchmark & Mentor specifically for IC[superscript 3] certification. The Internet and Computing Core Certification (IC[superscript 3]), as an industry-based credentialing program,…
Llamas: Large-area microphone arrays and sensing systems
NASA Astrophysics Data System (ADS)
Sanz-Robinson, Josue
Large-area electronics (LAE) provides a platform to build sensing systems, based on distributing large numbers of densely spaced sensors over a physically-expansive space. Due to their flexible, "wallpaper-like" form factor, these systems can be seamlessly deployed in everyday spaces. They go beyond just supplying sensor readings, but rather they aim to transform the wealth of data from these sensors into actionable inferences about our physical environment. This requires vertically integrated systems that span the entirety of the signal processing chain, including transducers and devices, circuits, and signal processing algorithms. To this end we develop hybrid LAE / CMOS systems, which exploit the complementary strengths of LAE, enabling spatially distributed sensors, and CMOS ICs, providing computational capacity for signal processing. To explore the development of hybrid sensing systems, based on vertical integration across the signal processing chain, we focus on two main drivers: (1) thin-film diodes, and (2) microphone arrays for blind source separation: 1) Thin-film diodes are a key building block for many applications, such as RFID tags or power transfer over non-contact inductive links, which require rectifiers for AC-to-DC conversion. We developed hybrid amorphous / nanocrystalline silicon diodes, which are fabricated at low temperatures (<200 °C) to be compatible with processing on plastic, and have high current densities (5 A/cm2 at 1 V) and high frequency operation (cutoff frequency of 110 MHz). 2) We designed a system for separating the voices of multiple simultaneous speakers, which can ultimately be fed to a voice-command recognition engine for controlling electronic systems. On a device level, we developed flexible PVDF microphones, which were used to create a large-area microphone array. On a circuit level we developed localized a-Si TFT amplifiers, and a custom CMOS IC, for system control, sensor readout and digitization. On a signal processing level we developed an algorithm for blind source separation in a real, reverberant room, based on beamforming and binary masking. It requires no knowledge about the location of the speakers or microphones. Instead, it uses cluster analysis techniques to determine the time delays for beamforming; thus, adapting to the unique acoustic environment of the room.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kriikku, E. M.; Hera, K. R.; Marzolf, A. D.
The Nuclear Material Disposition Project group asked the Savannah River National Lab (SRNL) Research and Development Engineering (R&DE) department to help procure, test, and deploy a remote crawler to recover the 2014 Inspection Crawler (IC) that tipped over in the H-Canyon Air Exhaust Tunnel. R&DE wrote a Procurement Specification for a Recovery Crawler (RC) and SRNS Procurement Department awarded the contract to Power Equipment Manufacturing Inc. (PEM). The PEM RC was based on their standard sewer inspection crawler with custom arms and forks added to the front. The arms and forks would be used to upright the 2014 Inspection Crawler.more » PEM delivered the RC and associated cable reel, 2014 Inspection Crawler mockup, and manuals in late April 2015. R&DE and the team tested the crawler in May of 2015 and made modifications based on test results and Savannah River Site (SRS) requirements. R&DE delivered the RC to H-Area at the end of May. The team deployed the RC on June 9, 10, and 11, 2015 in the H-Canyon Air Exhaust Tunnel. The RC struggled with some obstacles in the tunnel, but eventually made it to the IC. The team spent approximately five hours working to upright the IC and eventually got it on its wheels. The IC travelled approximately 20 feet and struggled to drive over debris on the air tunnel floor. Unfortunately the IC tripped over trying to pass this obstacle. The team decided to leave the IC in this location and inspect the tunnel with the RC. The RC passed the IC and inspected the tunnel as it travelled toward H-Canyon. The team turned the RC around when it was about 20 feet from the H-Canyon crossover tunnel. From that point, the team drove the RC past the manway towards the new sand filter and stopped approximately 20 feet from the new sand filter. The team removed the RC from the tunnel, decontaminated the RC, and stored it the manway building, 294-2H. The RC deployment confirmed the IC was not in a condition to perform useful tunnel inspections and would require significant maintenance to become inspection ready. The RC traveled approximately 660 feet in the tunnel and viewed the tunnel and ceiling wall surfaces that were not blocked by existing ducts. This deployment also documented the tunnel obstacles for future inspections. Overall, the RC deployment was a success.« less
NASA Astrophysics Data System (ADS)
Jacobs, J. L.
1993-04-01
Erasable programmable logic devices (EPLD's) were investigated to determine their advantages and/or disadvantages in Test Equipment Engineering applications. It was found that EPLD's performed as well as or better than identical circuits using standard transistor transistor logic (TTL). The chip count in these circuits was reduced, saving printed circuit board space and shortening fabrication and prove-in time. Troubleshooting circuits of EPLD's was also easier with 10 to 100 times fewer wires needed. The reduced number of integrated circuits (IC's) contributed to faster system speeds and an overall lower power consumption. In some cases changes to the circuit became software changes using EPLD's instead of hardware changes for standard logic. Using EPLD's was fairly easy; however, as with any new technology, a learning curve must be overcome before EPLD's can be used efficiently. The many benefits of EPLD's outweighed this initial inconvenience.
Multicolor CCD Photometry of the Open Cluster IC361
2010-01-01
journal Volume 19 Numbers 1/2 2010 Contents V. Straizys, A. Kazlauskas. Young stars in the Camelopardalis dust and molecular clouds. VI. YSOs...Vilnius + I system for 7250 stars down to 1= 19.6 mag has been obtained in the 20’ x 26’ field of the open cluster IC 361 in Camelopardalis . The catalog...1= 19.6 mag has been obtained in the 20’ x 26’ field of the open cluster IC 361 in Camelopardalis . The catalog of 1420 stars down to V ~ 18.5 mag
[Analysis of informed consent readibility in intensive care].
Ramírez-Puerta, M R; Fernández-Fernández, R; Frías-Pareja, J C; Yuste-Ossorio, M E; Narbona-Galdó, S; Peñas-Maldonado, L
2013-11-01
To analyze the readability of informed consent documents (IC) used in an intensive care department and in the Andalusian Healthcare System (AHS). A descriptive study was carried out. The Intensive Care Unit of a tertiary Hospital, and the AHS. A review and analysis was made of the existing 14 IC models in the Intensive Care Unit and of another 14 IC models offered by the AHS, using the following readability scores: Flesch, Sentence complexity, LEGIN, Fernández-Huerta, Szigriszt and INFLESZ. Twenty-four IC (85.7%) failed to satisfy some of the indexes, while three (10.7%) did not satisfy any of them. Four documents (14.3%) satisfied all the indexes analyzed, and therefore are easy to understand. Flesch score: satisfied by one of the ICU IC (7.1%) and by three of the AHS documents (21.4%). Sentence complexity score: satisfied by 11 of the ICU IC (78.6%) and by 13 of the AHS documents (92.8%). Fernández-Huerta score: satisfied by four of the ICU IC (28.6%) and by 13 of the AHS documents (92.8%). Szigriszt score: satisfied by two of the ICU IC (14.3%) and by 11 of the AHS documents (64.3%). INFLESZ score: satisfied by two of the ICU IC (14.3%) and by 10 of the AHS documents (71.4%). The documents analyzed are generally difficult to read and understand by most people, and do not satisfy the basic purpose for which they were drafted. Copyright © 2012 Elsevier España, S.L. and SEMICYUC. All rights reserved.
Bandurska, Ewa; Damps-Konstańska, Iwona; Popowski, Piotr; Jędrzejczyk, Tadeusz; Janowiak, Piotr; Świętnicka, Katarzyna; Zarzeczna-Baran, Marzena; Jassem, Ewa
2017-06-12
BACKGROUND Chronic obstructive pulmonary disease (COPD) is a commonly diagnosed condition in people older than 50 years of age. In advanced stage of this disease, integrated care (IC) is recommended as an optimal approach. IC allows for holistic and patient-focused care carried out at the patient's home. The aim of this study was to analyze the impact of IC on costs of care and on demand for medical services among patients included in IC. MATERIAL AND METHODS The study included 154 patients diagnosed with advanced COPD. Costs of care (general, COPD, and exacerbations-related) were evaluated for 1 year, including 6-months before and after implementing IC. The analysis included assessment of the number of medical procedures of various types before and after entering IC and changes in medical services providers. RESULTS Direct medical costs of standard care in advanced COPD were 886.78 EUR per 6 months. Costs of care of all types decreased after introducing IC. Changes in COPD and exacerbation-related costs were statistically significant (p=0.012492 and p=0.017023, respectively). Patients less frequently used medical services for respiratory system and cardiovascular diseases. Similarly, the number of hospitalizations and visits to emergency medicine departments decreased (by 40.24% and 8.5%, respectively). The number of GP visits increased after introducing IC (by 7.14%). CONCLUSIONS The high costs of care in advanced COPD indicate the need for new forms of effective care. IC caused a decrease in costs and in the number of hospitalization, with a simultaneous increase in the number of GP visits.
Scholze, Stefan; Schiefer, Stefan; Partzsch, Johannes; Hartmann, Stephan; Mayr, Christian Georg; Höppner, Sebastian; Eisenreich, Holger; Henker, Stephan; Vogginger, Bernhard; Schüffny, Rene
2011-01-01
State-of-the-art large-scale neuromorphic systems require sophisticated spike event communication between units of the neural network. We present a high-speed communication infrastructure for a waferscale neuromorphic system, based on application-specific neuromorphic communication ICs in an field programmable gate arrays (FPGA)-maintained environment. The ICs implement configurable axonal delays, as required for certain types of dynamic processing or for emulating spike-based learning among distant cortical areas. Measurements are presented which show the efficacy of these delays in influencing behavior of neuromorphic benchmarks. The specialized, dedicated address-event-representation communication in most current systems requires separate, low-bandwidth configuration channels. In contrast, the configuration of the waferscale neuromorphic system is also handled by the digital packet-based pulse channel, which transmits configuration data at the full bandwidth otherwise used for pulse transmission. The overall so-called pulse communication subgroup (ICs and FPGA) delivers a factor 25–50 more event transmission rate than other current neuromorphic communication infrastructures. PMID:22016720
MEMS-based tunable gratings and their applications
NASA Astrophysics Data System (ADS)
Yu, Yiting; Yuan, Weizheng; Qiao, Dayong
2015-03-01
The marriage of optics and MEMS has resulted in a new category of optical devices and systems that have unprecedented advantages compared with their traditional counterparts. As an important spatial light modulating technology, diffractive optical MEMS obtains a wide variety of successful commercial applications, e.g. projection displays, optical communication and spectral analysis, due to its features of highly compact, low-cost, IC-compatible, excellent performance, and providing possibilities for developing totally new, yet smart devices and systems. Three most successful MEMS diffraction gratings (GLVs, Polychromator and DMDs) are briefly introduced and their potential applications are analyzed. Then, three different MEMS tunable gratings developed by our group, named as micro programmable blazed gratings (μPBGs) and micro pitch-tunable gratings (μPTGs) working in either digital or analog mode, are demonstrated. The strategies to largely enhance the maximum blazed angle and grating period are described. Some preliminary application explorations based on the developed grating devices are also shown. For our ongoing research focus, we will further improve the device performance to meet the engineering application requirements.
Inter-computer communication architecture for a mixed redundancy distributed system
NASA Technical Reports Server (NTRS)
Lala, Jaynarayan H.; Adams, Stuart J.
1987-01-01
The triply redundant intercomputer network for the Advanced Information Processing System (AIPS), an architecture developed to serve as the core avionics system for a broad range of aerospace vehicles, is discussed. The AIPS intercomputer network provides a high-speed, Byzantine-fault-resilient communication service between processing sites, even in the presence of arbitrary failures of simplex and duplex processing sites on the IC network. The IC network contention poll has evolved from the Laning Poll. An analysis of the failure modes and effects and a simulation of the AIPS contention poll, demonstrate the robustness of the system.
Celebioglu, Asli; Kayaci-Senirmak, Fatma; İpek, Semran; Durgun, Engin; Uyar, Tamer
2016-07-13
Vanillin/cyclodextrin inclusion complex nanofibers (vanillin/CD-IC NFs) were successfully obtained from three modified CD types (HPβCD, HPγCD and MβCD) in three different solvent systems (water, DMF and DMAc) via an electrospinning technique without using a carrier polymeric matrix. Vanillin/CD-IC NFs with uniform and bead-free fiber morphology were successfully produced and their free-standing nanofibrous webs were obtained. The polymer-free CD/vanillin-IC-NFs allow us to accomplish a much higher vanillin loading (∼12%, w/w) when compared to electrospun polymeric nanofibers containing CD/vanillin-IC (∼5%, w/w). Vanillin has a volatile nature yet, after electrospinning, a significant amount of vanillin was preserved due to complex formation depending on the CD types. Maximum preservation of vanillin was observed for vanillin/MβCD-IC NFs which is up to ∼85% w/w, besides, a considerable amount of vanillin (∼75% w/w) was also preserved for vanillin/HPβCD-IC NFs and vanillin/HPγCD-IC NFs. Phase solubility studies suggested a 1 : 1 molar complexation tendency between guest vanillin and host CD molecules. Molecular modelling studies and experimental findings revealed that vanillin : CD complexation was strongest for MβCD when compared to HPβCD and HPγCD in vanillin/CD-IC NFs. For vanillin/CD-IC NFs, water solubility and the antioxidant property of vanillin was improved significantly owing to inclusion complexation. In brief, polymer-free vanillin/CD-IC NFs are capable of incorporating a much higher loading of vanillin and effectively preserve volatile vanillin. Hence, encapsulation of volatile active agents such as flavor, fragrance and essential oils in electrospun polymer-free CD-IC NFs may have potential for food related applications by integrating the particularly large surface area of NFs with the non-toxic nature of CD and inclusion complexation benefits, such as high temperature stability, improved water solubility and an enhanced antioxidant property, etc.
Ultrasound-triggered drug delivery using acoustic droplet vaporization
NASA Astrophysics Data System (ADS)
Fabiilli, Mario Leonardo
The goal of targeted drug delivery is the spatial and temporal localization of a therapeutic agent and its associated bioeffects. One method of drug localization is acoustic droplet vaporization (ADV), whereby drug-laden perfluorocarbon (PFC) emulsions are vaporized into gas bubbles using ultrasound, thereby releasing drug locally. Transpulmonary droplets are converted into bubbles that occlude capillaries, sequestering the released drug within an organ or tumor. This research investigates the relationship between the ADV and inertial cavitation (IC) thresholds---relevant for drug delivery due to the bioffects generated by IC---and explores the delivery of lipophilic and hydrophilic compounds using PFC double emulsions. IC can positively and negatively affect ultrasound mediated drug delivery. The ADV and IC thresholds were determined for various bulk fluid, droplet, and acoustic parameters. At 3.5 MHz, the ADV threshold occurred at a lower rarefactional pressure than the IC threshold. The results suggest that ADV is a distinct phenomenon from IC, the ADV nucleus is internal to the droplet, and the IC nucleus is the bubble generated by ADV. The ADV triggered release of a lipophilic chemotherapeutic agent, chlorambucil (CHL), from a PFC-in-oil-in-water emulsion was explored using plated cells. Cells exposed to a CHL-loaded emulsion, without ADV, displayed 44% less growth inhibition than cells exposed to an equal concentration of CHL in solution. Upon ADV of the CHL-loaded emulsion, the growth inhibition increased to the same level as cells exposed to CHL in solution. A triblock copolymer was synthesized which enabled the formulation of stable water-in-PFC-in-water (W1/PFC/W2) emulsions. The encapsulation of fluorescein in the W1 phase significantly decreased the mass flux of fluorescein; ADV was shown to completely release the fluorescein from the emulsions. ADV was also shown to release thrombin, dissolved in the W1 phase, which could be used in vivo to extend synergistically the duration of ADV-generated, microbubble-based embolizations. Overall, the results suggest that PFC double emulsions can be used as an ultrasound-triggered drug delivery system. Compared to traditional drug delivery systems, ADV could be used to increase the therapeutic efficacy and decrease the systemic toxicity of drug therapy.
Characterization of carbohydrate-protein matrices for nutrient delivery.
Zhou, Yankun; Roos, Yrjö H
2011-05-01
Amorphous carbohydrates may show glass transition and crystallization as a result of thermal or water plasticization. Proteins often affect the state transitions of carbohydrates in carbohydrate-protein systems. Water sorption behavior and effects of water on glass transition and crystallization in freeze-dried lactose, trehalose, lactose-casein (3: 1), lactose-soy protein isolate (3:1), trehalose-casein (3:1), and trehalose-soy protein isolate (3:1) systems were studied. Water sorption was determined gravimetrically as a function of time, and Brunauer-Emmett-Teller (BET) and Guggenheim-Anderson-de Boer (GAB) models were fitted to the experimental data. Glass transition temperature (T(g)) and instant crystallization temperature (T(ic)) in anhydrous and water plasticized systems were measured using differential scanning calorimetry (DSC). The Gordon-Taylor equation was used to model water content dependence of the T(g) values. The critical water content and water activity (a(w)) at 24 °C were calculated and crystallization of lactose and trehalose in the systems was followed at and above 0.54 a(w). Carbohydrate-protein systems showed higher amounts of sorbed water and less rapid sugar crystallization than pure sugars. A greater sugar crystallization delay was found in carbohydrate-casein systems than in carbohydrate-soy protein isolate systems. The T(g) and T(ic) values decreased with increasing water content and a(w). However, higher T(ic) values for lactose-protein systems were found than for lactose at the same a(w). Trehalose showed lower T(ic) value than lactose at 0.44 a(w) but no instant crystallization was measured below 0.44 a(w). State diagrams for each system are useful in selecting processing parameters and storage conditions in nutrient delivery applications. © 2011 Institute of Food Technologists®
Network security system for health and medical information using smart IC card
NASA Astrophysics Data System (ADS)
Kanai, Yoichi; Yachida, Masuyoshi; Yoshikawa, Hiroharu; Yamaguchi, Masahiro; Ohyama, Nagaaki
1998-07-01
A new network security protocol that uses smart IC cards has been designed to assure the integrity and privacy of medical information in communication over a non-secure network. Secure communication software has been implemented as a library based on this protocol, which is called the Integrated Secure Communication Layer (ISCL), and has been incorporated into information systems of the National Cancer Center Hospitals and the Health Service Center of the Tokyo Institute of Technology. Both systems have succeeded in communicating digital medical information securely.
NASA Team 2 Sea Ice Concentration Algorithm Retrieval Uncertainty
NASA Technical Reports Server (NTRS)
Brucker, Ludovic; Cavalieri, Donald J.; Markus, Thorsten; Ivanoff, Alvaro
2014-01-01
Satellite microwave radiometers are widely used to estimate sea ice cover properties (concentration, extent, and area) through the use of sea ice concentration (IC) algorithms. Rare are the algorithms providing associated IC uncertainty estimates. Algorithm uncertainty estimates are needed to assess accurately global and regional trends in IC (and thus extent and area), and to improve sea ice predictions on seasonal to interannual timescales using data assimilation approaches. This paper presents a method to provide relative IC uncertainty estimates using the enhanced NASA Team (NT2) IC algorithm. The proposed approach takes advantage of the NT2 calculations and solely relies on the brightness temperatures (TBs) used as input. NT2 IC and its associated relative uncertainty are obtained for both the Northern and Southern Hemispheres using the Advanced Microwave Scanning Radiometer for the Earth Observing System (AMSR-E) TB. NT2 IC relative uncertainties estimated on a footprint-by-footprint swath-by-swath basis were averaged daily over each 12.5-km grid cell of the polar stereographic grid. For both hemispheres and throughout the year, the NT2 relative uncertainty is less than 5%. In the Southern Hemisphere, it is low in the interior ice pack, and it increases in the marginal ice zone up to 5%. In the Northern Hemisphere, areas with high uncertainties are also found in the high IC area of the Central Arctic. Retrieval uncertainties are greater in areas corresponding to NT2 ice types associated with deep snow and new ice. Seasonal variations in uncertainty show larger values in summer as a result of melt conditions and greater atmospheric contributions. Our analysis also includes an evaluation of the NT2 algorithm sensitivity to AMSR-E sensor noise. There is a 60% probability that the IC does not change (to within the computed retrieval precision of 1%) due to sensor noise, and the cumulated probability shows that there is a 90% chance that the IC varies by less than +/-3%. We also examined the daily IC variability, which is dominated by sea ice drift and ice formation/melt. Daily IC variability is the highest, year round, in the MIZ (often up to 20%, locally 30%). The temporal and spatial distributions of the retrieval uncertainties and the daily IC variability is expected to be useful for algorithm intercomparisons, climate trend assessments, and possibly IC assimilation in models.
Construction Progress of the S-IC Test Stand-Pumps
NASA Technical Reports Server (NTRS)
1962-01-01
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, taken April 4, 1961, shows the S-IC test stand dry once again when workers resumed construction after a 6 month delay due to booster size reconfiguration back in September of 1961. The disturbance of a natural spring during the excavation of the site required water to be pumped from the site continuously. The site was completely flooded after the pumps were shut down during the construction delay.
ICS-II USA research design and methodology.
Rana, H; Andersen, R M; Nakazono, T T; Davidson, P L
1997-05-01
The purpose of the WHO-sponsored International Collaborative Study of Oral Health Outcomes (ICS-II) was to provide policy-markers and researchers with detailed, reliable, and valid data on the oral health situation in their countries or regions, together with comparative data from other dental care delivery systems. ICS-II used a cross-sectional design with no explicit control groups or experimental interventions. A standardized methodology was developed and tested for collecting and analyzing epidemiological, sociocultural, economic, and delivery system data. Respondent information was obtained by household interviews, and clinical examinations were conducted by calibrated oral epidemiologists. Discussed are the sampling design characteristics for the USA research locations, response rates, samples size for interview and oral examination data, weighting procedures, and statistical methods. SUDAAN was used to adjust variance calculations, since complex sampling designs were used.
Hsu, Min-Huei; Yeh, Yu-Ting; Chen, Chien-Yuan; Liu, Chien-Hsiang; Liu, Chien-Tsai
2011-03-01
Doctor shopping (or hospital shopping), which means changing doctors (or hospitals) without professional referral for the same or similar illness conditions, is common in Hong Kong, Taiwan and Japan. Due to the lack of infrastructure for sharing health information and medication history among hospitals, doctor-shopping patients are more likely to receive duplicate medications and suffer adverse drug reactions. The Bureau of National Health Insurance (BNHI) adopted smart cards (or NHI-IC cards) as health cards in Taiwan. With their NHI-IC cards, patients can freely access different medical institutions. Because an NHI-IC card carries information about a patient's prescribed medications received from different hospitals nationwide, we used this system to address the problem of duplicate medications for outpatients visiting multiple hospitals. A computerized physician order entry (CPOE) system was enhanced with the capability of accessing NHI-IC cards and providing alerts to physicians when the system detects potential duplicate medications at the time of prescribing. Physician responses to the alerts were also collected to analyze changes in physicians' behavior. Chi-square tests and two-sided z-tests with Bonferroni adjustments for multiple comparisons were used to assess statistical significance of differences in actions taken by physicians over the three months. The enhanced CPOE system for outpatient services was implemented and installed at the Pediatric and Urology Departments of Taipei Medical University Wan-Fang Hospital in March 2007. The "Change Log" that recorded physician behavior was activated during a 3-month study period from April to June 2007. In 67.93% of patient visits, the physicians read patient NHI-IC cards, and in 16.76% of the reads, the NHI-IC card contained at least one prescribed medication that was taken by the patient. Among the prescriptions issued by physicians, on average, there were 2.36% prescriptions containing at least one medication that might be duplicative to the prior prescriptions stored in NHI-IC cards. The rate of potential duplicate medication alerts for the Pediatric Department was higher than that for the Urology Department (2.78% versus 1.67%). However, the rate of revisions to prescriptions was higher in the Urology Department than the Pediatric Department. Overall, the rate of physicians reviewing and revising their prescriptions was 29.25%; the rate of physicians reviewing without revising their prescriptions was 43.62%; the rate of physicians turning off the alert screens right after the screens popped up (overridden) was 27.13%. Thus, physicians accepted alerts to review their prescriptions with patients in most situations (72.87%). Moreover, over the study period, the rate of total revisions made to prescriptions increased and the "overridden" rate decreased. Our approach enhances the capability of CPOE systems using NHI-IC cards as a nationwide infrastructure to provide more complete patient health information and medication history sharing among hospitals in Taiwan. Thus, our system can provide a better prescribing tool to help physicians detect potential duplicate medications for frequent doctor-shopping patients and hence enhance patient safety across hospital boundaries. However, the effectiveness of detecting duplicate medications with our approach is very much dependent on the completeness of NHI-IC cards, which in turn primarily depends on physician use of the cards when prescribing. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Analog/digital pH meter system I.C.
NASA Technical Reports Server (NTRS)
Vincent, Paul; Park, Jea
1992-01-01
The project utilizes design automation software tools to design, simulate, and fabricate a pH meter integrated circuit (IC) system including a successive approximation type seven-bit analog to digital converter circuits using a 1.25 micron N-Well CMOS MOSIS process. The input voltage ranges from 0.5 to 1.0 V derived from a special type pH sensor, and the output is a three-digit decimal number display of pH with one decimal point.
Posner, Karen L; Severson, Julie; Domino, Karen B
2015-09-01
Patient complaints about physicians are strongly associated with malpractice risk. Physicians at high risk for lawsuits tend to have poor communication skills and are more commonly the subject of patient complaints about communication issues. If a malpractice action does not arise, patient complaints nonetheless represent significant prelitigation transaction costs for the healthcare system that have not been previously quantified. Informed consent complaints represent a unique constellation of clinical communication skills clearly tied to malpractice risk. The goal of this study was to measure institutional resource consumption allocated to informed consent (IC) complaints, which are both costly and preventable. We compared IC complaints to other complaints about medical care in a single medical center in the United States, estimating the absolute and relative burden of IC deficiencies within this healthcare system. Resource consumption for the resolution of IC complaints far exceeded their proportional representation of complaints, representing half of all complaints, while disproportionately absorbing two-thirds of staff time devoted to complaint resolution. Complaint resolution represents an unrecognized remediable cost and an underappreciated opportunity for reducing waste in healthcare. We suggest that healthcare systems can reduce costs and elevate their patient-centered care practices by improving patient-provider communication during medical decision making via engagement strategies such as shared decision making. © 2015 American Society for Healthcare Risk Management of the American Hospital Association.
Inhaled corticosteroids for asthma: are they all the same?
Baptist, A P; Reddy, R C
2009-02-01
To assess similarities and differences among currently available inhaled corticosteroids (ICS) for treatment of asthma, with special emphasis on factors that may affect the relative safety of these medications. PubMed was searched for relevant reviews and original articles. Information from these studies was synthesized and critically assessed. Differences in corticosteroid formulations and delivery systems can create variations in therapeutic efficacy. Chemical properties of the various corticosteroids may also affect their relative safety. Ciclesonide and beclomethasone dipropionate are administered as prodrugs activated by enzymes present in the lungs but not the oropharynx. Corticosteroid-specific adverse effects in the oropharynx are thus avoided, although formulation-specific effects may remain. Other adverse effects require systemic availability, either via the gastrointestinal tract or the lung. Once they enter the systemic circulation, all ICS are rapidly metabolized by the liver. Oral bioavailability of ICS such as fluticasone, ciclesonide and mometasone is minimal, as a result of their essentially complete first-pass metabolism in the liver. Ciclesonide also undergoes extrahepatic metabolism that eliminates it even more rapidly. Additionally, ciclesonide and mometasone exhibit very high levels of binding to serum proteins that reduces their ability to stimulate glucocorticoid receptors outside the lung. Despite acting by similar mechanisms, currently available ICS and their delivery systems differ in ways that can potentially affect both safety and therapeutic effectiveness for individual patients.
Shulman, Nick; Bellew, Matthew; Snelling, George; Carter, Donald; Huang, Yunda; Li, Hongli; Self, Steven G.; McElrath, M. Juliana; De Rosa, Stephen C.
2008-01-01
Background Intracellular cytokine staining (ICS) by multiparameter flow cytometry is one of the primary methods for determining T cell immunogenicity in HIV-1 clinical vaccine trials. Data analysis requires considerable expertise and time. The amount of data is quickly increasing as more and larger trials are performed, and thus there is a critical need for high throughput methods of data analysis. Methods A web based flow cytometric analysis system, LabKey Flow, was developed for analyses of data from standardized ICS assays. A gating template was created manually in commercially-available flow cytometric analysis software. Using this template, the system automatically compensated and analyzed all data sets. Quality control queries were designed to identify potentially incorrect sample collections. Results Comparison of the semi-automated analysis performed by LabKey Flow and the manual analysis performed using FlowJo software demonstrated excellent concordance (concordance correlation coefficient >0.990). Manual inspection of the analyses performed by LabKey Flow for 8-color ICS data files from several clinical vaccine trials indicates that template gates can appropriately be used for most data sets. Conclusions The semi-automated LabKey Flow analysis system can analyze accurately large ICS data files. Routine use of the system does not require specialized expertise. This high-throughput analysis will provide great utility for rapid evaluation of complex multiparameter flow cytometric measurements collected from large clinical trials. PMID:18615598
Bladder Pain Syndrome/Interstitial Cystitis Is Associated with Hyperthyroidism
Liu, Shih-Ping; Lin, Ching-Chun; Lin, Herng-Ching
2013-01-01
Background Although the etiology of bladder pain syndrome/interstitial cystitis (BPS/IC) is still unclear, a common theme with BPS/IC patients is comorbid disorders which are related to the autonomic nervous system that connects the nervous system to end-organs. Nevertheless, no study to date has reported the association between hyperthyroidism and BPS/IC. In this study, we examined the association of IC/BPS with having previously been diagnosed with hyperthyroidism in Taiwan. Design Data in this study were retrieved from the Longitudinal Health Insurance Database. Our study consisted of 736 female cases with BPS/IC and 2208 randomly selected female controls. We performed a conditional logistic regression to calculate the odds ratio (OR) for having previously been diagnosed with hyperthyroidism between cases and controls. Results Of the 2944 sampled subjects, there was a significant difference in the prevalence of prior hyperthyroidism between cases and controls (3.3% vs. 1.5%, p<0.001). The conditional logistic regression analysis revealed that compared to controls, the OR for prior hyperthyroidism among cases was 2.16 (95% confidence interval (CI): 1.27∼3.66). Furthermore, the OR for prior hyperthyroidism among cases was 2.01 (95% CI: 1.15∼3.53) compared to controls after adjusting for diabetes, coronary heart disease, obesity, hyperlipidemia, chronic pelvic pain, irritable bowel syndrome, fibromyalgia, chronic fatigue syndrome, depression, panic disorder, migraines, sicca syndrome, allergies, endometriosis, and asthma. Conclusions Our study results indicated an association between hyperthyroidism and BPS/IC. We suggest that clinicians treating female subjects with hyperthyroidism be alert to urinary complaints in this population. PMID:23991081
Euler, A; Heye, T; Kekelidze, M; Bongartz, G; Szucs-Farkas, Z; Sommer, C; Schmidt, B; Schindera, Sebastian T
2015-03-01
To compare image quality and low-contrast detectability of an integrated circuit (IC) detector in abdominal CT of obese patients with conventional detector technology at low tube voltages. A liver phantom with 45 lesions was placed in a water container to mimic an obese patient and examined on two different CT systems at 80, 100 and 120 kVp. The systems were equipped with either the IC or conventional detector. Image noise was measured, and the contrast-to-noise-ratio (CNR) was calculated. Low-contrast detectability was assessed independently by three radiologists. Radiation dose was estimated by the volume CT dose index (CTDIvol). The image noise was significantly lower, and the CNR was significantly higher with the IC detector at 80, 100 and 120 kVp, respectively (P = 0.023). The IC detector resulted in an increased lesion detection rate at 80 kVp (38.1 % vs. 17.2 %) and 100 kVp (57.0 % vs. 41.0 %). There was no difference in the detection rate between the IC detector at 100 kVp and the conventional detector at 120 kVp (57.0 % vs. 62.2 %). The CTDIvol at 80, 100 and 120 kVp measured 4.5-5.2, 7.3-7.9 and 9.8-10.2 mGy, respectively. The IC detector at 100 kVp resulted in similar low-contrast detectability compared to the conventional detector with a 120-kVp protocol at a radiation dose reduction of 37 %.
Bladder pain syndrome/interstitial cystitis is associated with hyperthyroidism.
Chung, Shiu-Dong; Liu, Shih-Ping; Lin, Ching-Chun; Li, Hsien-Chang; Lin, Herng-Ching
2013-01-01
Although the etiology of bladder pain syndrome/interstitial cystitis (BPS/IC) is still unclear, a common theme with BPS/IC patients is comorbid disorders which are related to the autonomic nervous system that connects the nervous system to end-organs. Nevertheless, no study to date has reported the association between hyperthyroidism and BPS/IC. In this study, we examined the association of IC/BPS with having previously been diagnosed with hyperthyroidism in Taiwan. Data in this study were retrieved from the Longitudinal Health Insurance Database. Our study consisted of 736 female cases with BPS/IC and 2208 randomly selected female controls. We performed a conditional logistic regression to calculate the odds ratio (OR) for having previously been diagnosed with hyperthyroidism between cases and controls. Of the 2944 sampled subjects, there was a significant difference in the prevalence of prior hyperthyroidism between cases and controls (3.3% vs. 1.5%, p<0.001). The conditional logistic regression analysis revealed that compared to controls, the OR for prior hyperthyroidism among cases was 2.16 (95% confidence interval (CI): 1.27∼3.66). Furthermore, the OR for prior hyperthyroidism among cases was 2.01 (95% CI: 1.15∼3.53) compared to controls after adjusting for diabetes, coronary heart disease, obesity, hyperlipidemia, chronic pelvic pain, irritable bowel syndrome, fibromyalgia, chronic fatigue syndrome, depression, panic disorder, migraines, sicca syndrome, allergies, endometriosis, and asthma. Our study results indicated an association between hyperthyroidism and BPS/IC. We suggest that clinicians treating female subjects with hyperthyroidism be alert to urinary complaints in this population.
Porous filtering media comparison through wet and dry sampling of fixed bed gasification products
NASA Astrophysics Data System (ADS)
Allesina, G.; Pedrazzi, S.; Montermini, L.; Giorgini, L.; Bortolani, G.; Tartarini, P.
2014-11-01
The syngas produced by fixed bed gasifiers contains high quantities of particulate and tars. This issue, together with its high temperature, avoids its direct exploitation without a proper cleaning and cooling process. In fact, when the syngas produced by gasification is used in an Internal Combustion engine (IC), the higher the content of tars and particulate, the higher the risk to damage the engine is. If these compounds are not properly removed, the engine may fail to run. A way to avoid engine fails is to intensify the maintenance schedule, but these stops will reduce the system profitability. From a clean syngas does not only follow higher performance of the generator, but also less pollutants in the atmosphere. When is not possible to work on the gasification reactions, the filter plays the most important role in the engine safeguard process. This work is aimed at developing and comparing different porous filters for biomass gasifiers power plants. A drum filter was developed and tested filling it with different filtering media available on the market. As a starting point, the filter was implemented in a Power Pallet 10 kW gasifier produced by the California-based company "ALL Power Labs". The original filter was replaced with different porous biomasses, such as woodchips and corn cobs. Finally, a synthetic zeolites medium was tested and compared with the biological media previously used. The Tar Sampling Protocol (TSP) and a modified "dry" method using the Silica Gel material were applied to evaluate the tars, particulate and water amount in the syngas after the filtration process. Advantages and disadvantages of every filtering media chosen were reported and discussed.
An NFC-Enabled CMOS IC for a Wireless Fully Implantable Glucose Sensor.
DeHennis, Andrew; Getzlaff, Stefan; Grice, David; Mailand, Marko
2016-01-01
This paper presents an integrated circuit (IC) that merges integrated optical and temperature transducers, optical interface circuitry, and a near-field communication (NFC)-enabled digital, wireless readout for a fully passive implantable sensor platform to measure glucose in people with diabetes. A flip-chip mounted LED and monolithically integrated photodiodes serve as the transduction front-end to enable fluorescence readout. A wide-range programmable transimpedance amplifier adapts the sensor signals to the input of an 11-bit analog-to-digital converter digitizing the measurements. Measurement readout is enabled by means of wireless backscatter modulation to a remote NFC reader. The system is able to resolve current levels of less than 10 pA with a single fluorescent measurement energy consumption of less than 1 μJ. The wireless IC is fabricated in a 0.6-μm-CMOS process and utilizes a 13.56-MHz-based ISO15693 for passive wireless readout through a NFC interface. The IC is utilized as the core interface to a fluorescent, glucose transducer to enable a fully implantable sensor-based continuous glucose monitoring system.
Graham, Anthony H. D.; Robbins, Jon; Bowen, Chris R.; Taylor, John
2011-01-01
The adaptation of standard integrated circuit (IC) technology as a transducer in cell-based biosensors in drug discovery pharmacology, neural interface systems and electrophysiology requires electrodes that are electrochemically stable, biocompatible and affordable. Unfortunately, the ubiquitous Complementary Metal Oxide Semiconductor (CMOS) IC technology does not meet the first of these requirements. For devices intended only for research, modification of CMOS by post-processing using cleanroom facilities has been achieved. However, to enable adoption of CMOS as a basis for commercial biosensors, the economies of scale of CMOS fabrication must be maintained by using only low-cost post-processing techniques. This review highlights the methodologies employed in cell-based biosensor design where CMOS-based integrated circuits (ICs) form an integral part of the transducer system. Particular emphasis will be placed on the application of multi-electrode arrays for in vitro neuroscience applications. Identifying suitable IC packaging methods presents further significant challenges when considering specific applications. The various challenges and difficulties are reviewed and some potential solutions are presented. PMID:22163884
NASA Astrophysics Data System (ADS)
McQuiddy, David N., Jr.; Sokolov, Vladimir
1990-12-01
The present conference discusses microwave filters, lightwave technology for microwave antennas, planar and quasi-planar guides, mixers and VCOs, cavity filters, discontinuity and coupling effects, control circuits, power dividers and phase shifters, microwave ICs, biological effects and medical applications, CAD and modeling for MMICs, directional couplers, MMIC design trends, microwave packaging and manufacturing, monolithic ICs, and solid-state devices and circuits. Also discussed are microwave and mm-wave superconducting technology, MICs for communication systems, the merging of optical and microwave technologies, microwave power transistors, ferrite devices, network measurements, advanced transmission-line structures, FET devices and circuits, field theory of IC discontinuities, active quasi-optical techniques, phased-array techniques and circuits, nonlinear CAD, sub-mm wave devices, and high power devices.
Charge imbalance and Josephson effects in superconductor-normal metal mesoscopic structures
NASA Astrophysics Data System (ADS)
Volkov, A. F.
2007-11-01
We consider a SBS Josephson junction the superconducting electrodes S of which are in contact with normal metal reservoirs ( B means a barrier). For temperatures near Tc we calculate an effective critical current Ic* and the resistance of the system at the currents I
High duty cycle inverse Compton scattering X-ray source
Ovodenko, A.; Agustsson, R.; Babzien, M.; ...
2016-12-22
Inverse Compton Scattering (ICS) is an emerging compact X-ray source technology, where the small source size and high spectral brightness are of interest for multitude of applications. However, to satisfy the practical flux requirements, a high-repetition-rate ICS system needs to be developed. To this end, this article reports the experimental demonstration of a high peak brightness ICS source operating in a burst mode at 40 MHz. A pulse train interaction has been achieved by recirculating a picosecond CO 2 laser pulse inside an active optical cavity synchronized to the electron beam. The pulse train ICS performance has been characterized atmore » 5- and 15- pulses per train and compared to a single pulse operation under the same operating conditions. Lastly, with the observed near-linear X-ray photon yield gain due to recirculation, as well as noticeably higher operational reliability, the burst-mode ICS offers a great potential for practical scalability towards high duty cycles.« less
History of the KC-10A Aircraft Acquisition
1988-04-01
in other research reports or educational pursuits contingent upon the following stipulations: - Reproduction rights do not extend to any copyrighted...MAC, AFLC, and others) would create data for flight, maintenance, and technical data manuals, and evaluate human engineering factors. This testing...productio); ond deli.erme:; ra.. a fa:st rate and the acquisition program began to phase out.. The, total fleot gjrew to 52 aircraft, and del ivf , ics of th:ý
Microcomputer Software Engineering, Documentation and Evaluation
1981-03-31
local dealer or call for complete specificalons. eAUTOMATIC INC To proceed step by step, we need toUe G T A TOMA IC NC. know where we are going and a...MICROPROCESSOR normal sequence that should be DIRECT MEMORY ACCESS preserved in the documentation. For INTRODUCTION 2.2 DRIVE CONTROLS example, you...with linear, sequential logic (like a computer). It is also the verbal side and controls language. The right side specializes in images, music, pictures
Fluid Dynamic - Structural Interactions of Labyrinth Seals.
1986-08-01
A., "The Leakage of Steam Through Labyrinth Seals ", Trans. ASME, Vol. 57, 1935, pp 115-122. 21. Komotori, K., "A Consideration on the Labyrinth ...October 1980. 17. Vermes, G., "A fluid-Mechanics Approach to the Labyrinth Seal Leakage Problem", Journal of Basic Engineering, Tr. ASME, Series D...INTERACTIONS OF LABYRINTH SEALS Manuel Martinez-Sanchez John Dugundji Gas Turbine and Plasma Dynamics Laboratory D T IC Department of Aeronautics and
Biological Effects of Electromagnetic Radiation. Volume II, Number 4.
1975-12-01
Physics Group and professor of electrical engineering, is investigating the limiting of such lines or im— began the two year study after serving on an...Agric. For., Tokyo, Japan), and disturbances in erection , ejaculation , and/or T. Kobaymshi , 0. Mamiya, H. Tamiya , K. Sasaki , and orgasm ...life and physical sciences. The Current state of ORAL VARIATION OF EXTREMELY LOW FREQUENCY 11 -~ ~~ H Biological Ef f e c ts Electromagnet ic
Modelling of an advanced charging system for electric vehicles
NASA Astrophysics Data System (ADS)
Hassan Jaafar, Abdul; Rahman, Ataur; Mohiuddin, A. K. M.; Rashid, Mahbubur
2017-03-01
Climate Change is recognized as one of the greatest environmental problem facing the World today and it has long been appreciated by governments that reducing the impact of the internal combustion (IC) engine powered motor vehicle has an important part to play in addressing this threat. In Malaysia, IC engine powered motor vehicle accounts almost 90% of the national greenhouse gas (GHG) emissions. The need to reduce the emission is paramount, as Malaysia has pledged to reduce 40% of CO2 intensity by 2020 from 2005 level by 25% of improvement in average fuel consumption. The introduction of electric vehicles (EVs) is one of the initiatives. However in terms of percentage, the electric vehicles have not been commonly used by people nowadays and one of the reasons is lack in charging infrastructure especially when cars are on the road. The aim of this study is to simulate and model an advanced charging system for the charging infrastructure of EVs/HEVs all over the nation with slow charging mode with charging current 25 A, medium charging mode with charging current 50 A and fast charging mode with charging current 100 A. The slow charging mode is proposed for residence, medium charging mode for office parking lots, and fast charging mode is called fast charging track for charging station on road. With three modes charger topology, consumers could choose a suitable mode for their car based on their need. The simulation and experiment of advanced charging system has been conducted on a scale down battery pack of nominal voltage of 3.75 V and capacity of 1020 mAh. Result shows that the battery could be charging less than 1 hour with fast charging mode. However, due to limitation of Tenaga Nasional Berhad (TNB) power grid, the maximum 50 A current is considered to be the optimized passive mode for the EV’s battery charging system. The developed advanced charger prototype performance has been compared with the simulation result and conventional charger performance, the maximum variation has been found 15%, this closed agreement between the advanced charger prototype, simulation model and conventional charger validate the prototype model. Furthermore, based on the result presented in this report, the battery to be charged up to 85% of its rated capacity by constant current mode only rather than continue with constant voltage, which could shorten the battery charging time by 16% and prolong the battery life by 10%.
NASA Astrophysics Data System (ADS)
Chen, Jian; Randall, Robert Bond; Peeters, Bart
2016-06-01
Artificial Neural Networks (ANNs) have the potential to solve the problem of automated diagnostics of piston slap faults, but the critical issue for the successful application of ANN is the training of the network by a large amount of data in various engine conditions (different speed/load conditions in normal condition, and with different locations/levels of faults). On the other hand, the latest simulation technology provides a useful alternative in that the effect of clearance changes may readily be explored without recourse to cutting metal, in order to create enough training data for the ANNs. In this paper, based on some existing simplified models of piston slap, an advanced multi-body dynamic simulation software was used to simulate piston slap faults with different speeds/loads and clearance conditions. Meanwhile, the simulation models were validated and updated by a series of experiments. Three-stage network systems are proposed to diagnose piston faults: fault detection, fault localisation and fault severity identification. Multi Layer Perceptron (MLP) networks were used in the detection stage and severity/prognosis stage and a Probabilistic Neural Network (PNN) was used to identify which cylinder has faults. Finally, it was demonstrated that the networks trained purely on simulated data can efficiently detect piston slap faults in real tests and identify the location and severity of the faults as well.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Havarinasab, S.; Hultman, P.
Inorganic mercury may aggravate murine systemic autoimmune diseases which are either spontaneous (genetically determined) or induced by non-genetic mechanisms. Organic mercury species, the dominating form of mercury exposure in the human population, have not been examined in this respect. Therefore, ethyl mercury in the form of thimerosal, a preservative recently debated as a possible health hazard when present in vaccines, was administered in a dose of 0.156-5 mg/L drinking water to female (NZB x NZW)F1 (ZBWF1) mice. These mice develop an age-dependent spontaneous systemic autoimmune disease with high mortality primarily due to immune-complex (IC) glomerulonephritis. Five mg thimerosal/L drinking watermore » (295 {mu}g Hg/kg body weight (bw)/day) for 7 weeks induced glomerular, mesangial and systemic vessel wall IC deposits and antinuclear antibodies (ANA) which were not present in the untreated controls. After 22-25 weeks, the higher doses of thimerosal had shifted the localization of the spontaneously developing renal glomerular IC deposits from the capillary wall position seen in controls to the mesangium. The altered localization was associated with less severe histological kidney damage, less proteinuria, and reduced mortality. The effect was dose-dependent, lower doses having no effect compared with the untreated controls. A different effect of thimerosal treatment was induction of renal and splenic vessel walls IC deposits. Renal vessel wall deposits occurred at a dose of 0.313-5 mg thimerosal/L (18-295 {mu}g Hg/kg bw/day), while splenic vessel wall deposits developed also in mice given the lowest dose of thimerosal, 0.156 mg/L (9 {mu}g Hg/kg bw/day). The latter dose is 3- and 15-fold lower than the dose of Hg required to induce vessel wall IC deposits in genetically susceptible H-2 {sup s} mice by HgCl{sub 2} and thimerosal, respectively. Further studies on the exact conditions needed for induction of systemic IC deposits by low-dose organic mercurials in autoimmune-prone individuals, as well as the potential effect of these deposits on the vessel walls, are warranted.« less
O'Connor, Michael; Lee, Caroline; Ellens, Harma; Bentz, Joe
2015-02-01
Current USFDA and EMA guidance for drug transporter interactions is dependent on IC50 measurements as these are utilized in determining whether a clinical interaction study is warranted. It is therefore important not only to standardize transport inhibition assay systems but also to develop uniform statistical criteria with associated probability statements for generation of robust IC50 values, which can be easily adopted across the industry. The current work provides a quantitative examination of critical factors affecting the quality of IC50 fits for P-gp inhibition through simulations of perfect data with randomly added error as commonly observed in the large data set collected by the P-gp IC50 initiative. The types of errors simulated were (1) variability in replicate measures of transport activity; (2) transformations of error-contaminated transport activity data prior to IC50 fitting (such as performed when determining an IC50 for inhibition of P-gp based on efflux ratio); and (3) the lack of well defined "no inhibition" and "complete inhibition" plateaus. The effect of the algorithm used in fitting the inhibition curve (e.g., two or three parameter fits) was also investigated. These simulations provide strong quantitative support for the recommendations provided in Bentz et al. (2013) for the determination of IC50 values for P-gp and demonstrate the adverse effect of data transformation prior to fitting. Furthermore, the simulations validate uniform statistical criteria for robust IC50 fits in general, which can be easily implemented across the industry. A calibration of the t-statistic is provided through calculation of confidence intervals associated with the t-statistic.
Bandurska, Ewa; Damps-Konstańska, Iwona; Popowski, Piotr; Jędrzejczyk, Tadeusz; Janowiak, Piotr; Świętnicka, Katarzyna; Zarzeczna-Baran, Marzena; Jassem, Ewa
2017-01-01
Background Chronic obstructive pulmonary disease (COPD) is a commonly diagnosed condition in people older than 50 years of age. In advanced stage of this disease, integrated care (IC) is recommended as an optimal approach. IC allows for holistic and patient-focused care carried out at the patient’s home. The aim of this study was to analyze the impact of IC on costs of care and on demand for medical services among patients included in IC. Material/Methods The study included 154 patients diagnosed with advanced COPD. Costs of care (general, COPD, and exacerbations-related) were evaluated for 1 year, including 6-months before and after implementing IC. The analysis included assessment of the number of medical procedures of various types before and after entering IC and changes in medical services providers. Results Direct medical costs of standard care in advanced COPD were 886.78 EUR per 6 months. Costs of care of all types decreased after introducing IC. Changes in COPD and exacerbation-related costs were statistically significant (p=0.012492 and p=0.017023, respectively). Patients less frequently used medical services for respiratory system and cardiovascular diseases. Similarly, the number of hospitalizations and visits to emergency medicine departments decreased (by 40.24% and 8.5%, respectively). The number of GP visits increased after introducing IC (by 7.14%). Conclusions The high costs of care in advanced COPD indicate the need for new forms of effective care. IC caused a decrease in costs and in the number of hospitalization, with a simultaneous increase in the number of GP visits. PMID:28603270
O'Connor, Michael; Lee, Caroline; Ellens, Harma; Bentz, Joe
2015-01-01
Current USFDA and EMA guidance for drug transporter interactions is dependent on IC50 measurements as these are utilized in determining whether a clinical interaction study is warranted. It is therefore important not only to standardize transport inhibition assay systems but also to develop uniform statistical criteria with associated probability statements for generation of robust IC50 values, which can be easily adopted across the industry. The current work provides a quantitative examination of critical factors affecting the quality of IC50 fits for P-gp inhibition through simulations of perfect data with randomly added error as commonly observed in the large data set collected by the P-gp IC50 initiative. The types of errors simulated were (1) variability in replicate measures of transport activity; (2) transformations of error-contaminated transport activity data prior to IC50 fitting (such as performed when determining an IC50 for inhibition of P-gp based on efflux ratio); and (3) the lack of well defined “no inhibition” and “complete inhibition” plateaus. The effect of the algorithm used in fitting the inhibition curve (e.g., two or three parameter fits) was also investigated. These simulations provide strong quantitative support for the recommendations provided in Bentz et al. (2013) for the determination of IC50 values for P-gp and demonstrate the adverse effect of data transformation prior to fitting. Furthermore, the simulations validate uniform statistical criteria for robust IC50 fits in general, which can be easily implemented across the industry. A calibration of the t-statistic is provided through calculation of confidence intervals associated with the t-statistic. PMID:25692007
Magnetic fields in the torus of AGN and Mid-IR polarimetry of Cygnus A
NASA Astrophysics Data System (ADS)
Lopez-Rodriguez, E.; Packham, C.; Young, S.; Elitzur, M.; Levenson, N. A.; Mason, R. E.; Ramos Almeida, C.; Alonso-Herrero, A.; Jones, T. J.; Perlman, E.
2012-12-01
An optically and geometrically thick torus obscures the central engine of Active Galactic Nuclei (AGN) from some lines of sight. From a magnetohydrodynamical framework, the torus can be considered to be a particular region of clouds surrounding the central engine where the clouds are dusty and optically thick. In this framework, the magnetic field plays an important role in the creation, morphology and evolution of the torus. If the dust grains within the clouds are assumed to be aligned by paramagnetic alignment, then the ratio of the intrinsic polarisation and visual extinction, P(%)/Av, is a function of the magnetic field strength. To estimate the visual extinction through the torus and constrain the polarisation mechanisms in the nucleus of AGN, we developed a polarisation model to fit both the total and polarised flux in a 1.2" (˜ 263 pc) aperture of the type 2 AGN, IC5063. We consider the physical conditions and environment of the gas and dust for the torus of IC5063. Then, through paramagnetic alignment, we estimate a magnetic field strength in the range of 12 - 128 mG in the NIR emitting regions of the torus of IC5063. Alternatively, we estimate the magnetic field strength in the plane of the sky using the Chandrasekhar-Fermi method. The minimum magnetic field strength in the plane of the sky is estimated to be 13 and 41 mG depending of the conditions within the torus of IC5063. These techniques afford the chance to make a survey of AGN, to investigate the effects of magnetic field strength on the torus, accretion, and interaction to the host galaxy. We present Si2 [8.7 um] and Si5 [11.6 um] imaging polarimetry of Cygnus A using CanariCam on the 10.4-m Gran Telescopio de Canarias (GTC). Preliminary polarimetric results show a highly polarized nucleus with 11±3% and 12±3% in a 0.5" (˜500pc) aperture in Si2 and Si5, respectively. The PA of polarization remains constant, 32±8 deg, in both filters. In order to disentangle the origin of the polarized component in the nucleus of Cygnus A, further modeling using several polarizing mechanisms e.g. synchrotron, dichroic absorption/emission and/or scattering will be performed.
Silicon CMOS optical receiver circuits with integrated thin-film compound semiconductor detectors
NASA Astrophysics Data System (ADS)
Brooke, Martin A.; Lee, Myunghee; Jokerst, Nan Marie; Camperi-Ginestet, C.
1995-04-01
While many circuit designers have tackled the problem of CMOS digital communications receiver design, few have considered the problem of circuitry suitable for an all CMOS digital IC fabrication process. Faced with a high speed receiver design the circuit designer will soon conclude that a high speed analog-oriented fabrication process provides superior performance advantages to a digital CMOS process. However, for applications where there are overwhelming reasons to integrate the receivers on the same IC as large amounts of conventional digital circuitry, the low yield and high cost of the exotic analog-oriented fabrication is no longer an option. The issues that result from a requirement to use a digital CMOS IC process cut across all aspects of receiver design, and result in significant differences in circuit design philosophy and topology. Digital ICs are primarily designed to yield small, fast CMOS devices for digital logic gates, thus no effort is put into providing accurate or high speed resistances, or capacitors. This lack of any reliable resistance or capacitance has a significant impact on receiver design. Since resistance optimization is not a prerogative of the digital IC process engineer, the wisest option is thus to not use these elements, opting instead for active circuitry to replace the functions normally ascribed to resistance and capacitance. Depending on the application receiver noise may be a dominant design constraint. The noise performance of CMOS amplifiers is different than bipolar or GaAs MESFET circuits, shot noise is generally insignificant when compared to channel thermal noise. As a result the optimal input stage topology is significantly different for the different technologies. It is found that, at speeds of operation approaching the limits of the digital CMOS process, open loop designs have noise-power-gain-bandwidth tradeoff performance superior to feedback designs. Furthermore, the lack of good resisters and capacitors complicates the use of feedback circuits. Thus feedback is generally not used in the front-end of our digital process CMOS receivers.
Creating a FIESTA (Framework for Integrated Earth Science and Technology Applications) with MagIC
NASA Astrophysics Data System (ADS)
Minnett, R.; Koppers, A. A. P.; Jarboe, N.; Tauxe, L.; Constable, C.
2017-12-01
The Magnetics Information Consortium (https://earthref.org/MagIC) has recently developed a containerized web application to considerably reduce the friction in contributing, exploring and combining valuable and complex datasets for the paleo-, geo- and rock magnetic scientific community. The data produced in this scientific domain are inherently hierarchical and the communities evolving approaches to this scientific workflow, from sampling to taking measurements to multiple levels of interpretations, require a large and flexible data model to adequately annotate the results and ensure reproducibility. Historically, contributing such detail in a consistent format has been prohibitively time consuming and often resulted in only publishing the highly derived interpretations. The new open-source (https://github.com/earthref/MagIC) application provides a flexible upload tool integrated with the data model to easily create a validated contribution and a powerful search interface for discovering datasets and combining them to enable transformative science. MagIC is hosted at EarthRef.org along with several interdisciplinary geoscience databases. A FIESTA (Framework for Integrated Earth Science and Technology Applications) is being created by generalizing MagIC's web application for reuse in other domains. The application relies on a single configuration document that describes the routing, data model, component settings and external services integrations. The container hosts an isomorphic Meteor JavaScript application, MongoDB database and ElasticSearch search engine. Multiple containers can be configured as microservices to serve portions of the application or rely on externally hosted MongoDB, ElasticSearch, or third-party services to efficiently scale computational demands. FIESTA is particularly well suited for many Earth Science disciplines with its flexible data model, mapping, account management, upload tool to private workspaces, reference metadata, image galleries, full text searches and detailed filters. EarthRef's Seamount Catalog of bathymetry and morphology data, EarthRef's Geochemical Earth Reference Model (GERM) databases, and Oregon State University's Marine and Geology Repository (http://osu-mgr.org) will benefit from custom adaptations of FIESTA.
1963-10-22
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the progress of the S-IC test stand as of October 22, 1963. Spherical liquid hydrogen tanks can be seen to the left. Just to the lower front of those are the cylindrical liquid oxygen (LOX) tanks.
1963-09-05
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. In the center portion of this photograph, taken September 5, 1963, the spherical hydrogen storage tanks are being constructed. One of the massive tower legs of the S-IC test stand is visible to the far right.
1961-06-01
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this photo, taken July 13, 1961, progress is being made with the excavation of the S-IC test stand site. During the digging, a natural spring was disturbed which caused a constant flooding problem. Pumps were used to remove the water all through the construction process and the site is still pumped today.
1963-03-29
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In the early stages of excavation, a natural spring was disturbed that caused a water problem which required constant pumping from the site and is even pumped to this day. Behind this reservoir of pumped water is the S-IC test stand boasting its ever-growing four towers as of March 29, 1963.
Late-time spectroscopy of envelope-stripped SNe: Figuring the central engine
NASA Astrophysics Data System (ADS)
Kawabata, Koji
2011-01-01
We propose to perform late-time spectroscopy of envelope-stripped core-collapse supernovae (SNe), i.e., Type Ib/c/IIb SNe. We aim to examine the explosion physics and its dependence on the progenitor mass. The key information is the asphericity and the chemical composition of the inner atmosphere, which can be explored by late-time observations. The difference in [O I] line profiles indicates that GRB-associated energetic SNe Ic (like SN 1998bw) and non-GRB energetic SNe Ic (2003jd) are intrinsically similar aspherical explosions that are differently viewed (pole-on for 1998bw and nearly edge-on for 2003jd). Our continuing study suggests that the asphericity is rather common characteristic even for normal energy SNe without a GRB. However, it is still unclear how the intermediate types of SNe (SNe Ib/IIb) are produced and how they connected with other types of core-collapse SNe. High-quality late-time spectra of SNe Ib/Ic/IIb are still lacking. We propose to obtain a larger number of nebular spectra of envelope-stripped SNe so that we examine the degree of the asphericity as a function of the progenitor's mass, explosion energy, amount of synthesized ^56Ni, and the physical properties of the central remnant.
Late-time spectroscopy of envelope-stripped SNe: Figuring the central engine
NASA Astrophysics Data System (ADS)
Kawabata, Koji
2012-01-01
We propose to perform late-time spectroscopy of envelope-stripped core-collapse supernovae (SNe), i.e., Type Ib/c/IIb SNe. We aim to examine the explosion physics and its dependence on the progenitor mass. The key information is the asphericity and the chemical composition of the inner atmosphere, which can be explored by late-time observations. The difference in [O I] line profiles indicates that GRB-associated energetic SNe Ic (like SN 1998bw) and non-GRB energetic SNe Ic (2003jd) are intrinsically similar aspherical explosions that are differently viewed (pole-on for 1998bw and nearly edge-on for 2003jd). Our continuing study suggests that the asphericity is rather common characteristic even for normal energy SNe without a GRB. However, it is still unclear how the intermediate types of SNe (SNe Ib/IIb) are produced and how they connected with other types of core-collapse SNe. High-quality late-time spectra of SNe Ib/Ic/IIb are still lacking. We propose to obtain a larger number of nebular spectra of envelope-stripped SNe including SNe IIb so that we examine the degree of the asphericity explosion energy, amount of synthesized ^56Ni and the physical properties of the central remnant as a function of the progenitor's mass.
Sikdar, Jyotirmoy; Seal, Paromita; Roy, Amartya; Haldar, Rajen
2017-04-01
Erythrocytes in cigarette smokers are prone to oxidative damage. Here, we sought to elucidate the facts behind modifications and possible defense system developed in erythrocyte of cigarette smokers. We observed significant increase in stomatocytes and spherocytes, and osmotic fragility of erythrocyte, along with reduced level of protein thiol and increased fluorescence anisotropy in isolated membrane. Denaturing gel electrophoresis indicated alterations in band 3, band 4.2 and band 4.5. Among those, Glut 1 (i.e. band 4.5), which transports glucose (insulin independent) and dehydroascorbate (DHA), was selectively chosen for its long history in reducing reactive oxygen species (ROS). The increased Glut 1 level in smokers was confirmed by immunoblotting and immunocytochemistry. Furthermore, smokers showed significantly higher glucose uptake in whole blood. The intracellular (Ic) ROS (as indicated by 2',7'-dichlorofluorescin) was significantly higher in smokers as evidenced by flow cytometric assay. Glucose and DHA alone or together significantly reduced IcROS at higher rate in smokers. However, in presence of Glut 1 specific blocker, phloretin, neither glucose nor DHA could reduce IcROS in both non-smokers and smokers. This confirms that Glut 1 by transporting glucose or DHA attenuates IcROS. Therefore, we conclude that erythrocytes, although altered morphologically, also develop a defense system by upregulating Glut 1 to combat with enhanced Ic oxidative insult in cigarette smokers.
Duell, Daisy; Koolman, Xander; Portrait, France
2017-12-01
Universal access and generous coverage are important goals of the Dutch long-term care (LTC) system. It is a legal requirement that everyone eligible for LTC should be able to receive it. Institutional care (IC) made up for 90% of Dutch LTC spending. To investigate whether access to IC is as equitable as the Dutch government aspires, we explored practice variation in entitlements to IC across Dutch regions. We used a unique dataset that included all individual applications for Dutch LTC in January 2010-December 2013 (N = 3,373,358). This dataset enabled an accurate identification of the need for care. We examined the local variation in the probability of being granted long-term IC and in the intensity of the care granted given that individuals have applied for LTC. We also investigated whether the variation observed was related to differences in the local availability of care facilities. Although our analyses indicated the presence of some practice variation, its magnitude was very small by national and international standards (up to 3%). Only a minor part of the practice variation could be accounted for by local supply differences in care facilities. Overall, we conclude that, unlike many other developed countries, the Dutch system ensured equitable access to long-term IC. © 2017 The Authors. Health Economics Published by John Wiley & Sons Ltd.
Design and performance of clock-recovery GaAs ICs for high-speed optical communication systems
NASA Astrophysics Data System (ADS)
Imai, Yuhki; Sano, Eiichi; Nakamura, Makoto; Ishihara, Noboru; Kikuchi, Hiroyuki; Ono, Takashi
1993-05-01
Design and performance of clock-recovery GaAs ICs are presented. Four kinds of ICs were developed: a limiting amplifier, a tuning amplifier, a rectifier, and a differentiator. The cascaded limiting amplifier together with a tuning amplifier achieved a 58-dB gain and a 10-degree phase deviation with 20-dB input dynamic range at 10 GHz. A clock-recovery circuit successfully extracts a low-jitter 10-GHz clock signal of 1-dBm constant power from 10-Gb/s NRZ pseudorandom bit streams using a pulse pattern generator.
Simultaneous and iterative weighted regression analysis of toxicity tests using a microplate reader.
Galgani, F; Cadiou, Y; Gilbert, F
1992-04-01
A system is described for determination of LC50 or IC50 by an iterative process based on data obtained from a plate reader using a marine unicellular alga as a target species. The esterase activity of Tetraselmis suesica on fluorescein diacetate as a substrate was measured using a fluorescence titerplate. Simultaneous analysis of results was performed using an iterative process adopting the sigmoid function Y = y/1 (dose of toxicant/IC50)slope for dose-response relationships. IC50 (+/- SEM) was estimated (P less than 0.05). An application with phosalone as a toxicant is presented.
Novel Manufacturing Technologies for GHZ/THz Integrated Circuits on Synthetic Diamond Substrates
2010-11-15
silicon form palladium silicide Pd2Si at a temperature of 400 ºС, thus ensuring high reliability of the contacts. All the above metallization layers were...indicate possibility of realization of ICs on diamond substrates. In the course of our studies it was found that the Ti-Pd-Au metallization system...thickness of 2-3 um) can be applied when forming the topology of IC elements on synthetic diamond layers, while the Cr–Cu–Ni–Au metallization system with
Ichesco, Eric; Quintero, Andres; Clauw, Daniel J; Peltier, Scott; Sundgren, Pia M; Gerstner, Geoffrey E; Schmidt-Wilcke, Tobias
2012-03-01
Among the most common chronic pain conditions, yet poorly understood, are temporomandibular disorders (TMDs), with a prevalence estimate of 3-15% for Western populations. Although it is increasingly acknowledged that central nervous system mechanisms contribute to pain amplification and chronicity in TMDs, further research is needed to unravel neural correlates that might abet the development of chronic pain. The insular cortex (IC) and cingulate cortex (CC) are both critically involved in the experience of pain. The current study sought specifically to investigate IC-CC functional connectivity in TMD patients and healthy controls (HCs), both during resting state and during the application of a painful stimulus. Eight patients with TMD, and 8 age- and sex-matched HCs were enrolled in the present study. Functional magnetic resonance imaging data during resting state and during the performance of a pressure pain stimulus to the temple were acquired. Predefined seed regions were placed in the IC (anterior and posterior insular cortices) and the extracted signal was correlated with brain activity throughout the whole brain. Specifically, we were interested whether TMD patients and HCs would show differences in IC-CC connectivity, both during resting state and during the application of a painful stimulus to the face. As a main finding, functional connectivity analyses revealed an increased functional connectivity between the left anterior IC and pregenual anterior cingulate cortex (ACC) in TMD patients, during both resting state and applied pressure pain. Within the patient group, there was a negative correlation between the anterior IC-ACC connectivity and clinical pain intensity as measured by a visual analog scale. Since the pregenual region of the ACC is critically involved in antinociception, we hypothesize that an increase in anterior IC-ACC connectivity is indicative of an adaptation of the pain modulatory system early in the chronification process. © 2011 American Headache Society.
van Hell, Hendrika H; Bossong, Matthijs G; Jager, Gerry; Kahn, René S; Ramsey, Nick F
2011-03-01
Various lines of (pre)clinical research indicate that cannabinoid agents carry the potential for therapeutic application to reduce symptoms in several psychiatric disorders. However, direct testing of the involvement of cannabinoid brain systems in psychiatric syndromes is essential for further development. In the Pharmacological Imaging of the Cannabinoid System (PhICS) study, the involvement of the endocannabinoid system in cognitive brain function is assessed by comparing acute effects of the cannabinoid agonist Δ9-tetrahydrocannabinol (THC) on brain function between healthy controls and groups of psychiatric patients showing cognitive dysfunction. This article describes the objectives and methods of the PhICS study and presents preliminary results of the administration procedure on subjective and neurophysiological parameters. Core elements in the methodology of PhICS are the administration method (THC is administered by inhalation using a vaporizing device) and a comprehensive use of pharmacological magnetic resonance imaging (phMRI) combining several types of MRI scans including functional MRI (fMRI), Arterial Spin Labeling (ASL) to measure brain perfusion, and resting-state fMRI. Additional methods like neuropsychological testing further specify the exact role of the endocannabinoid system in regulating cognition. Preliminary results presented in this paper indicate robust behavioral and subjective effects of THC. In addition, fMRI paradigms demonstrate activation of expected networks of brain regions in the cognitive domains of interest. The presented administration and assessment protocol provides a basis for further research on the involvement of the endocannabionoid systems in behavior and in psychopathology, which in turn may lead to development of therapeutic opportunities of cannabinoid ligands. Copyright © 2011 John Wiley & Sons, Ltd.
Reddel, Helen K; Beckert, Lutz; Moran, Angela; Ingham, Tristram; Ampon, Rosario D; Peters, Matthew J; Sawyer, Susan M
2017-11-01
New Zealand (NZ) and Australia (AU) have similarly high asthma prevalence; both have universal public health systems, but different criteria for subsidized medicines. We explored differences in asthma management and asthma-related outcomes between these countries. A web-based survey was administered in AU (2012) and NZ (2013) to individuals aged ≥16 years with current asthma, drawn randomly from web-based panels, stratified by national population proportions. Symptom control was assessed with the Asthma Control Test (ACT). Healthcare utilization was assessed from reported urgent doctor/hospital visits in the previous year. NZ (n = 537) and Australian (n = 2686) participants had similar age and gender distribution. More NZ than Australian participants used inhaled corticosteroid (ICS)-containing medication (68.8% vs 60.9%; P = 0.006) but ICS/long-acting β 2 -agonist (LABA) constituted 44.4% of NZ and 81.5% of Australian total ICS use (P < 0.0001). Adherence was higher with ICS/LABA than ICS-alone (P < 0.0001), and higher in NZ than in AU (P < 0.0001). ACT scores were similar (P = 0.41), with symptoms well controlled in 58.6% and 54.4% participants, respectively. More NZ participants reported non-urgent asthma reviews (56.6% vs 50.4%; P = 0.009). Similar proportions had urgent asthma visits (27.9% and 28.6%, respectively, P = 0.75). This comparison, which included the first nationally representative data for asthma control in NZ, showed that poorly controlled asthma is common in both NZ and AU, despite subsidized ICS-containing medications. The greater use of ICS-alone in NZ relative to ICS/LABA does not appear to have compromised population-level asthma outcomes, perhaps due to better adherence in NZ. Different ICS/LABA subsidy criteria and different patient copayments may also have contributed to these findings. © 2017 Asian Pacific Society of Respirology.
CONSTITUENCY IN A SYSTEMIC DESCRIPTION OF THE ENGLISH CLAUSE.
ERIC Educational Resources Information Center
HUDSON, R.A.
TWO WAYS OF DESCRIBING CLAUSES IN ENGLISH ARE DISCUSSED IN THIS PAPER. THE FIRST, TERMED THE "FEW-IC'S" APPROACH, IS A SEGMENTATION OF THE CLAUSE INTO A SMALL NUMBER OF IMMEDIATE CONSTITUENTS WHICH REQUIRE A LARGE NUMBER OF FURTHER SEGMENTATIONS BEFORE THE ULTIMATE CONSTITUENTS ARE REACHED. THE SECOND, "MANY-IC'S" APPROACH, IS A SEGMENTATION INTO…
Application of Ion Chromatography to the Investigation of Real-World Samples
ERIC Educational Resources Information Center
Whelan, Rebecca J.; Hannon, Theresa E.; Zare, Richard N.
2004-01-01
The use of ion chromatography (IC) as a means to teach important analytical concepts while giving the students a valuable opportunity to identify and investigate a real-world system of interest to them is described. A single IC apparatus can be tailored for different classes of analyses by the selection of different column-eluent combinations.
Aytac, Zeynep; Uyar, Tamer
2017-02-25
Core-shell nanofibers were designed via electrospinning using inclusion complex (IC) of model hydrophobic drug (curcumin, CUR) with cyclodextrin (CD) in the core and polymer (polylactic acid, PLA) in the shell (cCUR/HPβCD-IC-sPLA-NF). CD-IC of CUR and HPβCD was formed at 1:2 molar ratio. The successful formation of core-shell nanofibers was revealed by TEM and CLSM images. cCUR/HPβCD-IC-sPLA-NF released CUR slowly but much more in total than PLA-CUR-NF at pH 1 and pH 7.4 due to the restriction of CUR in the core of nanofibers and solubility improvement shown in phase solubility diagram, respectively. Improved antioxidant activity of cCUR/HPβCD-IC-sPLA-NF in methanol:water (1:1) is related with the solubility enhancement achieved in water based system. The slow reaction of cCUR/HPβCD-IC-sPLA-NF in methanol is associated with the shell inhibiting the quick release of CUR. On the other hand, cCUR/HPβCD-IC-sPLA-NF exhibited slightly higher rate of antioxidant activity than PLA-CUR-NF in methanol:water (1:1) owing to the enhanced solubility. To conclude, slow release of CUR was achieved by core-shell nanofiber structure and inclusion complexation of CUR with HPβCD provides high solubility. Briefly, electrospinning of core-shell nanofibers with CD-IC core could offer slow release of drugs as well as solubility enhancement for hydrophobic drugs. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, Xiaoyan; Gao, Jiong; Zhu, Zheng; Dong, Xianxin; Wang, Xiaolei; Ren, Guodong; Zhou, Xin; Kuai, Benke
2015-04-01
Salicylic acid (SA) plays an important role in various aspects of plant development and responses to stresses. To elucidate the sophisticated regulatory mechanism of SA synthesis and signaling, we used a yeast one-hybrid system to screen for regulators of isochorismate synthase 1 (ICS1), a gene encoding the key enzyme in SA biosynthesis in Arabidopsis thaliana. A TCP family transcription factor AtTCP8 was initially identified as a candidate regulator of ICS1. The regulation of ICS1 by TCP proteins is supported by the presence of a typical TCP binding site in the ICS1 promoter. The binding of TCP8 to this site was confirmed by in vitro and in vivo assays. Expression patterns of TCP8 and its corresponding gene TCP9 largely overlapped with ICS1 under pathogen attack. A significant reduction in the expression of ICS1 during immune responses was observed in the tcp8 tcp9 double mutant. We also detected strong interactions between TCP8 and SAR deficient 1 (SARD1), WRKY family transcription factor 28 (WRKY28), NAC (NAM/ATAF1,ATAF2/CUC2) family transcription factor 019 (NAC019), as well as among TCP8, TCP9 and TCP20, suggesting a complex coordinated regulatory mechanism underlying ICS1 expression. Our results collectively demonstrate that TCP proteins are involved in the orchestrated regulation of ICS1 expression, with TCP8 and TCP9 being verified as major representatives. © 2015 The Authors The Plant Journal © 2015 John Wiley & Sons Ltd.
Dalbak, Lene G; Rognstad, Sture; Melbye, Hasse; Straand, Jørund
2013-06-01
Inhaled glucocorticosteroids (ICS) are first-line anti-inflammatory treatment in asthma, but not in chronic obstructive pulmonary disease (COPD). To restrict ICS use in COPD to cases of severe disease, new terms for reimbursement of drug costs were introduced in Norway in 2006, requiring a diagnosis of COPD to be verified by spirometry. To describe how GPs' diagnoses and treatment of patients who used ICS before 2006 changed after a reassessment of the patients that included spirometry. From the shared electronic patient record system in one group practice, patients ≥ 50 years prescribed ICS (including in combination with long-acting beta2-agonists) during the previous year were identified and invited to a tailored consultation including spirometry to assure the quality of diagnosis and treatment. GPs' diagnoses and ICS prescribing patterns after this reassessment were recorded, retrospectively. Of 164 patients identified, 112 were included. Post-bronchodilator spirometry showed airflow limitation indicating COPD in 55 patients. Of the 57 remaining patients, five had a positive reversibility test. The number of patients diagnosed with asthma increased (from 25 to 62) after the reassessment. A diagnosis of COPD was also more frequently used, whereas fewer patients had other pulmonary diagnoses. ICS was discontinued in 31 patients; 20 with mild to moderate COPD and 11 with normal spirometry. Altered reimbursement terms for ICS changed GPs' diagnostic practice in a way that made the diagnoses better fit with the treatment given, but over-diagnosis of asthma could not be excluded. Spirometry was useful for identifying ICS overuse.
Who cares for involuntary clients?
Soliman, Soheil; Pollack, Harold A; Alexander, Jeffrey A
2009-01-01
The objectives of this study were to compare characteristics of outpatient substance abuse treatment (OSAT) units that serve high proportions of involuntary clients (ICs) with those that serve a low percentage of such clients. The authors analyze unit-level 1995-2005 data from the National Drug Abuse Treatment System Survey (NDATSS). Approximately 1/6 of OSAT units draw the dominant majority of their clients from involuntary referrals. OSAT units that treat a high proportion of ICs are less likely to be accredited by professional organizations, have fewer treatment staff with advanced degrees, and have shorter average treatment duration than do OSAT units that serve few ICs. OSAT units that serve ICs are more likely to offer legal and domestic violence services but are less likely to offer mental health services or aftercare. OSAT units that serve ICs are less likely to be hospital-affiliated than are other units. Clients at such facilities are more likely to be convicted of driving while intoxicated (DWI), are younger, are less likely to have received prior treatment, are more likely to remain abstinent after treatment, but are more likely to be remanded back to courts. The authors conclude that ICs are an important market niche in OSAT care. DWI is by far the most common offense reported in units that specialize in ICs. Aside from legal and domestic violence services, units with a high proportion of ICs appear to offer somewhat less intensive and professionalized services than do other facilities; however, clients at these units are more likely to be abstinent at the end of treatment and but more likely to be remanded back to the courts.
The Host Galaxies of Fast-Ejecta Core-Collapse Supernovae
NASA Technical Reports Server (NTRS)
Kelly, Patrick L.; Filippenko, Alexei V.; Modjaz, Maryam; Kocevski, Daniel
2014-01-01
Spectra of broad-lined Type Ic supernovae (SN Ic-BL), the only kind of SN observed at the locations of long-duration gamma-ray bursts (LGRBs), exhibit wide features indicative of high ejecta velocities ((is) approximately 0.1c). We study the host galaxies of a sample of 245 low-redshift (z (is) less than 0.2) core-collapse SN, including 17 SN Ic-BL, discovered by galaxy-untargeted searches, and 15 optically luminous and dust-obscured z (is) less than 1.2 LGRBs. We show that, in comparison with SDSS galaxies having similar stellar masses, the hosts of low-redshift SN Ic- BL and z (is) is less than 1.2 LGRBs have high stellar-mass and star-formation-rate densities. Core-collapse SN having typical ejecta velocities, in contrast, show no preference for such galaxies. Moreover, we find that the hosts of SN Ic-BL, unlike those of SN Ib/Ic and SN II, exhibit high gas velocity dispersions for their stellar masses. The patterns likely reflect variations among star-forming environments, and suggest that LGRBs can be used as probes of conditions in high-redshift galaxies. They may be caused by efficient formation of massive binary progenitors systems in densely star-forming regions, or, less probably, a higher fraction of stars created with the initial masses required for a SN Ic-BL or LGRB. Finally, we show that the preference of SN Ic-BL and LGRBs for galaxies with high stellar-mass and star-formation-rate densities cannot be attributed to a preference for low metal abundances but must reflect the influence of a separate environmental factor.
Porous Diblock Copolymer Thin Films in High-Performance Semiconductor Microelectronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Black, C.T.
2011-02-01
The engine fueling more than 40 years of performance improvements in semiconductor integrated circuits (ICs) has been industry's ability to pattern circuit elements at ever-higher resolution and with ever-greater precision. Steady advances in photolithography - the process wherein ultraviolet light chemically changes a photosensitive polymer resist material in order to create a latent image - have resulted in scaling of minimum printed feature sizes from tens of microns during the 1980s to sub-50 nanometer transistor gate lengths in today's state-of-the-art ICs. The history of semiconductor technology scaling as well as future technology requirements is documented in the International Technology Roadmapmore » for Semiconductors (ITRS). The progression of the semiconductor industry to the realm of nanometer-scale sizes has brought enormous challenges to device and circuit fabrication, rendering performance improvements by conventional scaling alone increasingly difficult. Most often this discussion is couched in terms of field effect transistor (FET) feature sizes such as the gate length or gate oxide thickness, however these challenges extend to many other aspects of the IC, including interconnect dimensions and pitch, device packing density, power consumption, and heat dissipation. The ITRS Technology Roadmap forecasts a difficult set of scientific and engineering challenges with no presently-known solutions. The primary focus of this chapter is the research performed at IBM on diblock copolymer films composed of polystyrene (PS) and poly(methyl-methacrylate) (PMMA) (PS-b-PMMA) with total molecular weights M{sub n} in the range of {approx}60K (g/mol) and polydispersities (PD) of {approx}1.1. These materials self assemble to form patterns having feature sizes in the range of 15-20nm. PS-b-PMMA was selected as a self-assembling patterning material due to its compatibility with the semiconductor microelectronics manufacturing infrastructure, as well as the significant body of existing research on understanding its material properties.« less
Asnaashari, Maryam; Farhoosh, Reza; Sharif, Ali
2014-09-15
The anti-DPPH radical effect as well as anti-peroxide activity of gallic acid, methyl gallate, and α-tocopherol in a bulk Kilka fish oil and its oil-in-water emulsion stabilized by soy protein isolate at 55°C were investigated. Gallic acid with the lowest hydrophobicity (log P=-0.28) was found to be the most active antiradical agent (IC50=29.5 μM), followed by methyl gallate (IC50=38.0 μM, log P=-0.23) and α-tocopherol (IC50=105.3 μM, log P=0.70). The anti-peroxide activity in the bulk oil system decreased in the order of methyl gallate>gallic acid>α-tocopherol. In the emulsion system, methyl gallate still behaved better than gallic acid, but the highest activity belonged to α-tocopherol. Based on the calculation of a number of kinetic parameters, the antioxidants, in general, showed better performances in the bulk oil system than in the emulsion system. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ion Chromatography-on-a-chip for Water Quality Analysis
NASA Technical Reports Server (NTRS)
Kidd, R. D.; Noell, A.; Kazarians, G.; Aubrey, A. D.; Scianmarello, N.; Tai, Y.-C.
2015-01-01
We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.
Chander, G.; Haque, Md. O.; Micijevic, E.; Barsi, J.A.
2008-01-01
From the Landsat program's inception in 1972 to the present, the earth science user community has benefited from a historical record of remotely sensed data. The multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provide the backbone for this extensive archive. Historically, the radiometric calibration procedure for this imagery used the instrument's response to the Internal Calibrator (IC) on a scene-by-scene basis to determine the gain and offset for each detector. The IC system degraded with time causing radiometric calibration errors up to 20 percent. In May 2003 the National Landsat Archive Production System (NLAPS) was updated to use a gain model rather than the scene acquisition specific IC gains to calibrate TM data processed in the United States. Further modification of the gain model was performed in 2007. L5 TM data that were processed using IC prior to the calibration update do not benefit from the recent calibration revisions. A procedure has been developed to give users the ability to recalibrate their existing Level-1 products. The best recalibration results are obtained if the work order report that was originally included in the standard data product delivery is available. However, many users may not have the original work order report. In such cases, the IC gain look-up table that was generated using the radiometric gain trends recorded in the NLAPS database can be used for recalibration. This paper discusses the procedure to recalibrate L5 TM data when the work order report originally used in processing is not available. A companion paper discusses the generation of the NLAPS IC gain and bias look-up tables required to perform the recalibration.
Smy, Laura; Shaw, Kaitlyn; Amstutz, Ursula; Staub, Michelle; Chaudhry, Shahnaz; Smith, Anne; Carleton, Bruce; Koren, Gideon
2018-06-01
Inhaled corticosteroids (ICS) are the recommended long-term control therapy for asthma in children. However, concern exists regarding potential adrenal suppression with chronic ICS use. Our pilot study reported that hair cortisol in children was 50% lower during ICS therapy than prior to therapy, suggestive of adrenal suppression. To evaluate hair cortisol concentration (HCC) as a potential biomarker for possible adrenal suppression from ICS use in children with asthma. A retrospective observational study was performed at asthma clinics in Vancouver, Winnipeg, and Toronto, Canada. Children (n = 586) were recruited from July 2012 to December 2014 inclusive of those without asthma, with asthma not using ICS, and with asthma using ICS. The most recent three-month HCC was measured by enzyme immunoassay and compared among the groups. Quantile regression analysis was performed to identify factors potentially affecting HCC. The median HCC was not significantly different among the children: No ICS (n = 47, 6.7 ng/g, interquartile range (IQR) 3.7-9.8 ng/g), ICS Treated (n = 360, 6.5 ng/g, IQR 3.8-14.3 ng/g), and Controls (n = 53, 5.8 ng/g, IQR 4.6-16.7 ng/g). 5.6% of the children using ICS had hair cortisol <2.0 ng/g compared to none in the control groups (P < .05, comparing ICS Treated (20/360) to all Controls combined (0/100)) and only half had been exposed to systemic corticosteroids. Age, sex, BMI, and intranasal corticosteroid use were significantly associated with HCC. Results suggest HCC may be a potential biomarker for adrenal suppression as a population of children using ICS with HCC < 2.0 ng/g was identified compared to none in the control groups. Further research is needed to determine if those children have or are at risk of adrenal suppression or insufficiency. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Theoretical Prediction of Vibrational Circular Dichroism Spectra
1990-01-01
Chabalowski U.S. ARMY BALLISTIC RESEARCH LABORATORY January 1990 DTIC ELECTESMAR 6U99 CHEMICAL COMMAN4D Aberden Proving Ground . MeMand 21010-5423 IDWPM...TASK [WORK UNIT ELEMENT NO. NO.11 46 2 6 2 2 NO. A5531 ACCESSION NO. Aberdeen Proving Ground , MD 21010-5423 IC4648061 D020 1 11. TITLE (Include...Engineering Center ATITN: SDCCR-RSP-C Aberdeen Proving Ground , MD 21010-5423 U.S. Army Ballistic Research Laboratory Aberdeen Proving Ground , MD
1985-12-01
cation impurities from the plating solution and anodes to oxidize trivalent chromium to hexavalent chromium . Hexa- . valent chromium ions remain on the...corrosion, or to improve its engineering properties (harlness, durability, solderability, or frictional characteristics). Chromium ic used principally...facturing consists of machining the worn part or stripping a portion of the old plate, overplating it with a thick layer of chromium (hard chrome plating
1985-06-01
HPFTP Blade Airfoil 1984. Mass VS Frequency of Excitation 5 . R.J. Dominic, "Turbine Blade Damping Study," University of ACHNOWLEDGEMENT Dayton Research ...Damping Practices JUNE 1985 A Publication of TH-E SHOCK ANI) VIBRATION INFORMATION CENTER Naval Research Laboratory, Washington, I).C.- DTIC OCT 1686...Office ofE The Under Secretary of Defense for Research and Engineering Approved for public release; distribution unlimited. 85 10 15 027
1964-09-01
This photograph shows the components for the Saturn V S-IC stage fuel tank assembly in the Manufacturing Engineering Laboratory, building 4707, at the Marshall Space Flight Center (MSFC). Left to right are upper head, lower head, and forward skirt assembly. Thirty-three feet in diameter, they will hold a total of 4,400,000 pounds of fuel. Although this tankage was assembled at MSFC, the elements were made by the Boeing Company at Wichita and the Michould Operations at New Orleans.
Human Engineering Aspects of a Deep Dive Facility.
1977-03-01
Whit" Sectin " DDC Buff S ection r UNANNO¶!’CV D r , JUSTI’ IC .", ,",ON ........ .. . . . . . . . . ............................... DYIlSIRIDtI !fla...would consist mainly of coffee, tea, hot chocolate, or soup and cookies , crackers or other dried food that can be kept without refrigeration. It is...should be used in the Living Chamber. Age..-.. . • :YLi 13 The final recommended decor is based on the use of three basic shades: cream (Munsell 5Y 9/1
Assessing the Performance of Imaging Health Systems in Five Selected Hospitals in Uganda
Kawooya, Michael G.; Pariyo, George; Malwadde, Elsie Kiguli; Byanyima, Rosemary; Kisembo, Harriet
2012-01-01
Objectives: The first objective of the study was to develop an index termed as the ‘Imaging Coverage’ (IC), for measuring the performance of the imaging health systems. This index together with the Hospital-Based Utilization (HBU) would then be calculated for five Ugandan hospitals. Second, was to relate the financial resources and existing health policy to the performance of the imaging systems. Materials and Methods: This was a cross-sectional survey employing the triangulation methodology, conducted in Mulago National Referral Hospital. The qualitative study used cluster sampling, in-depth interviews, focus group discussions, and self-administered questionnaires to explore the non-measurable aspects of the imaging systems’ performances. Results: The IC developed and tested as an index for the imaging system′s performance was 36%. General X-rays had the best IC followed by ultrasound. The Hospital-Based Utilization for the five selected hospitals was 186 per thousand and was the highest for general radiography followed by ultrasound. Conclusion: The IC for the five selected hospitals was 36% and the HBU was 186 per thousand, reflecting low performance levels, largely attributable to inadequate funding. There were shortfalls in imaging requisitions and inefficiencies in the imaging systems, financing, and health policy. Although the proportion of inappropriate imaging was small, reducing this inappropriateness even further would lead to a significant total saving, which could be channeled into investigating more patients. Financial resources stood out as the major limitation in attaining the desired performance and there is a need to increase budget funding so as to improve the performance of the imaging health systems. PMID:22530183
Report to the Institutional Computing Executive Group (ICEG) August 14, 2006
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carnes, B
We have delayed this report from its normal distribution schedule for two reasons. First, due to the coverage provided in the White Paper on Institutional Capability Computing Requirements distributed in August 2005, we felt a separate 2005 ICEG report would not be value added. Second, we wished to provide some specific information about the Peloton procurement and we have just now reached a point in the process where we can make some definitive statements. The Peloton procurement will result in an almost complete replacement of current M&IC systems. We have plans to retire MCR, iLX, and GPS. We will replacemore » them with new parallel and serial capacity systems based on the same node architecture in the new Peloton capability system named ATLAS. We are currently adding the first users to the Green Data Oasis, a large file system on the open network that will provide the institution with external collaboration data sharing. Only Thunder will remain from the current M&IC system list and it will be converted from Capability to Capacity. We are confident that we are entering a challenging yet rewarding new phase for the M&IC program. Institutional computing has been an essential component of our S&T investment strategy and has helped us achieve recognition in many scientific and technical forums. Through consistent institutional investments, M&IC has grown into a powerful unclassified computing resource that is being used across the Lab to push the limits of computing and its application to simulation science. With the addition of Peloton, the Laboratory will significantly increase the broad-based computing resources available to meet the ever-increasing demand for the large scale simulations indispensable to advancing all scientific disciplines. All Lab research efforts are bolstered through the long term development of mission driven scalable applications and platforms. The new systems will soon be fully utilized and will position Livermore to extend the outstanding science and technology breakthroughs the M&IC program has enabled to date.« less
Cortical modulation of auditory processing in the midbrain
Bajo, Victoria M.; King, Andrew J.
2013-01-01
In addition to their ascending pathways that originate at the receptor cells, all sensory systems are characterized by extensive descending projections. Although the size of these connections often outweighs those that carry information in the ascending auditory pathway, we still have a relatively poor understanding of the role they play in sensory processing. In the auditory system one of the main corticofugal projections links layer V pyramidal neurons with the inferior colliculus (IC) in the midbrain. All auditory cortical fields contribute to this projection, with the primary areas providing the largest outputs to the IC. In addition to medium and large pyramidal cells in layer V, a variety of cell types in layer VI make a small contribution to the ipsilateral corticocollicular projection. Cortical neurons innervate the three IC subdivisions bilaterally, although the contralateral projection is relatively small. The dorsal and lateral cortices of the IC are the principal targets of corticocollicular axons, but input to the central nucleus has also been described in some studies and is distinctive in its laminar topographic organization. Focal electrical stimulation and inactivation studies have shown that the auditory cortex can modify almost every aspect of the response properties of IC neurons, including their sensitivity to sound frequency, intensity, and location. Along with other descending pathways in the auditory system, the corticocollicular projection appears to continually modulate the processing of acoustical signals at subcortical levels. In particular, there is growing evidence that these circuits play a critical role in the plasticity of neural processing that underlies the effects of learning and experience on auditory perception by enabling changes in cortical response properties to spread to subcortical nuclei. PMID:23316140
The application of an improved gas and aerosol collector for ambient air pollutants in China
NASA Astrophysics Data System (ADS)
Dong, Huabin; Zeng, Limin; Zhang, Yuanhang; Hu, Min; Wu, Yusheng
2016-04-01
An improved Gas and Aerosol Collector (GAC) equipped with a newly designed aerosol collector and a set of dull-polished wet annular denuder (WAD) was developed by Peking University based on a Steam Jet Aerosol Collector (SJAC) sampler. Combined with Ion Chromatography (IC) the new sampler performed well in laboratory tests with high collection efficiencies for SO2 (above 98 %) and particulate sulfate (as high as 99.5 %). An inter-comparison between the GAC-IC system and the filter-pack method was performed and the results indicated that the GAC-IC system could supply reliable particulate sulfate, nitrate, chloride, and ammonium data in field measurement with a much wider range of ambient concentrations. From 2008 to 2015, dozens of big field campaigns (rural and coastal sites) were executed in different parts of China, the GAC-IC system took the chance having its field measurement performance checked repeatedly and provided high quality data in ambient conditions either under high loadings of pollutants or background area. Its measurements were highly correlated with data by other commercial instruments such as the SO2 analyzer, the HONO analyzer, a filter sampler, Aerosol Mass Spectrometer (AMS), etc. over a wide range of concentrations and proved particularly useful in future intensive campaigns or long-term monitoring stations to study various environmental issues such as secondary aerosol and haze formation. During these years of applications of GAC-IC in those field campaigns, we found some problems of several instruments running under field environment and some interesting results could also be drew from the large amount of data measured in near 20 provinces of China. Detail results will be demonstrated on the poster afterwards.