Wang, Xi-ming; Wu, Le-bin; Zhang, Yun-ting; Li, Zhen-jia; Liu, Chen
2006-11-01
To discuss the value of multi-slice CT dynamic enhancement scan in the diagnosis and treatment of colonic lymphomas. 16 patients with colonic lymphomas underwent multi-slice CT dynamic enhancement scans, images of axial and reconstructive images of VR, MPR and CTVE were analyzed, patients were respectively diagnosed. Appearances of primary colorectal lymphomas were categorized into focal and diffuse lesions. Focal and diffuse lesions were 6 and 10 patients, respectively. The accuracy rate of diagnosis was 87.5%. MSCT dynamic scan has distinctive superiority in diagnosis and treatment of colonic lymphomas.
FDG-Avid Portal Vein Tumor Thrombosis from Hepatocellular Carcinoma in Contrast-Enhanced FDG PET/CT
Nguyen, Xuan Canh; Nguyen, Dinh Song Huy; Ngo, Van Tan; Maurea, Simone
2015-01-01
Objective(s): In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT), complicating hepatocellular carcinoma (HCC) in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), which is a combination of dynamic liver CT scan, multiphase imaging, and whole-body PET scan. PET and CT DICOM images of patients were imported into the PET/CT imaging system for the re-analysis of contrast enhancement and FDG uptake in thrombus, the diameter of the involved portal vein, and characteristics of liver tumors and metastasis. Results: Two patients with previously untreated HCC and 7 cases with previously treated HCC had FDG-avid PVTT in contrast-enhanced FDG PET/CT scan. During the arterial phase of CT scan, portal vein thrombus showed contrast enhancement in 8 out of 9 patients (88.9%). PET scan showed an increased linear FDG uptake along the thrombosed portal vein in all patients. The mean greatest diameter of thrombosed portal veins was 1.8 ± 0.2 cm, which was significantly greater than that observed in normal portal veins (P<0.001). FDG uptake level in portal vein thrombus was significantly higher than that of blood pool in the reference normal portal vein (P=0.001). PVTT was caused by the direct extension of liver tumors. All patients had visible FDG-avid liver tumors in contrast-enhanced images. Five out of 9 patients (55.6%) had no extrahepatic metastasis, 3 cases (33.3%) had metastasis of regional lymph nodes, and 1 case (11.1%) presented with distant metastasis. The median estimated survival time of patients was 5 months. Conclusion: The intraluminal filling defect consistent with thrombous within the portal vein, expansion of the involved portal vein, contrast enhancement, and linear increased FDG uptake of the thrombus extended from liver tumor are findings of FDG-avid PVTT from HCC in contrast-enhanced FDG PET/CT. PMID:27408876
Aziz, Farooq; Bano, Khizra; Siddique, Ahmad Hassan; Bajwa, Sadia Zafar; Nazir, Aalia; Munawar, Anam; Shaheen, Ayesha; Saeed, Madiha; Afzal, Muhammad; Iqbal, M Zubair; Wu, Aiguo; Khan, Waheed S
2018-01-09
We report a novel strategy for the fabrication of lecithin-coated gold nanoflowers (GNFs) via single-step design for CT imaging application. Field-emission electron microscope confirmed flowers like morphology of the as-synthesized nanostructures. Furthermore, these show absorption peak in near-infrared (NIR) region at λ max 690 nm Different concentrations of GNFs are tested as a contrast agent in CT scans at tube voltage 135 kV and tube current 350 mA. These results are compared with same amount of iodine at same CT scan parameters. The results of in vitro CT scan study show that GNFs have good contrast enhancement properties, whereas in vivo study of rabbits CT scan shows that GNFs enhance the CT image clearly at 135 kV as compared to that of iodine. Cytotoxicity was studied and blood profile show minor increase of white blood cells and haemoglobin, whereas decrease of red blood cells and platelets.
Rebière, Marilou; Verburg, Frederik A; Palmowski, Moritz; Krohn, Thomas; Pietsch, Hubertus; Kuhl, Christiane K; Mottaghy, Felix M; Behrendt, Florian F
2012-08-01
To evaluate the influence of multiphase CT scanning and different intravenous contrast media on contrast enhancement, attenuation correction and image quality in combined PET/CT. 140 patients were prospectively enrolled for F-18-FDG-PET/CT including a low-dose unenhanced, arterial and venous contrast enhanced CT. The first (second) 70 patients, received contrast medium with 370 (300) mg iodine/ml. The iodine delivery rate (1.3mg/s) and total iodine load (44.4g) were identical for both groups. Contrast enhancement and maximum and mean standardized FDG uptake values (SUVmax and SUVmean) were determined for the un-enhanced, arterial and venous PET/CT at multiple anatomic sites and PET reconstructions were visually evaluated. Arterial contrast enhancement was significantly higher for the 300mg/ml contrast medium compared to 370mgI/ml at all anatomic sites. Venous enhancement was not different between the two contrast media. SUVmean and SUVmax were significantly higher for the contrast enhanced compared to the non-enhanced PET/CT at all anatomic sites (all P<0.001). Tracer uptake was significantly higher in the arterial than in the venous PET/CT in the arteries using both contrast media (all P<0.001). No differences in tracer uptake were found between the contrast media (all P>0.05). Visual assessment revealed no relevant differences between the different PET reconstructions. There is no relevant qualitative influence on the PET scan from the use of different intravenous contrast media in its various phases in combined multiphase PET/CT. For quantitative analysis of tracer uptake it is required to use an identical PET/CT protocol. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Habets, J; Meijer, T S; Meijer, R C A; Mali, W P Th M; Vonken, E-J P A; Budde, R P J
2012-01-01
Objectives Sutures with polytetrafluorethylene (PTFE) felt pledgets are commonly used in prosthetic heart valve (PHV) implantation. Paravalvular leakage can be difficult to distinguish from PTFE felt pledgets on multislice CT because both present as hyperdense structures. We assessed whether pledgets can be discriminated from contrast-enhanced solutions (blood/saline) on CT images based on attenuation difference in an ex vivo experiment and under in vivo conditions. Methods PTFE felt pledgets were sutured to the suture ring of a mechanical PHV and porcine aortic annulus, and immersed and scanned in four different contrast-enhanced (Ultravist®; 300 mg jopromide ml−1) saline concentrations (10.0, 12.0, 13.6 and 15.0 mg ml−1). Scanning was performed on a 256-slice scanner with eight different scan protocols with various tube voltage (100 kV, 120 kV) and tube current (400 mAs, 600 mAs, 800 mAs, 1000 mAs) settings. Attenuation of the pledgets and surrounding contrast-enhanced saline were measured. Additionally, the attenuation of pledgets and contrast-enhanced blood was measured on electrocardiography (ECG)-gated CTA scans of 19 patients with 22 PHVs. Results Ex vivo CT attenuation differences between the pledgets and contrast-enhanced solutions were larger by using higher tube voltages. CT attenuation values of the pledgets were higher than contrast-enhanced blood in patients: 420±26 Hounsfield units (mean±SD, range 383–494) and 288±41 Hounsfield units (range 202–367), respectively. Conclusions PTFE felt pledgets have consistently higher attenuation than surrounding contrast-enhanced blood. CT attenuation measurements therefore may help to differentiate pledgets from paravalvular leakage, and detect paravalvular leakage in patients with suspected PHV dysfunction. PMID:22919014
Zhang, Ying; Tang, Jian; Xu, Jianrong
2017-01-01
Background To investigate the value of dual energy computed tomography (DECT) parameters (including iodine concentration and monochromatic CT numbers) for predicting pure ground-glass nodules (pGGNs) of invasive adenocarcinoma (IA). Methods A total of 55 resected pGGNs evaluated with both unenhanced thin-section CT (TSCT) and enhanced DECT scans were included. Correlations between histopathology [adenocarcinoma in situ (AIS), minimally IA (MIA), and IA] and CT scan characteristics were examined. CT scan and clinicodemographic data were investigated by univariate and multivariate analysis to identify features that helped distinguish IA from AIS or MIA. Results Both normalized iodine concentration (NIC) of IA and slope of spectral curve [slope(k)] were not significantly different between IA and AIS or MIA. Size, performance of pleural retraction and enhanced monochromatic CT attenuation values of 120–140 keV were significantly higher for IA. In multivariate regression analysis, size and enhanced monochromatic CT number of 140 keV were independent predictors for IA. Using the two parameters together, the diagnostic capacity of IA could be improved from 0.697 or 0.635 to 0.713. Conclusions DECT could help demonstrate blood supply and indicate invasion extent of pGGNs, and monochromatic CT number of higher energy (especially 140 keV) would be better for diagnosing IA than lower energies. Together with size of pGGNs, the diagnostic capacity of IA could be better. PMID:29312701
Conrad, R; Pauleit, D; Layer, G; Kandyba, J; Kohlbecher, R; Hortling, N; Baselides, P; Schild, H
1999-07-01
To determine if scanning in the arterial phase improves detection of squamous cell carcinomas in the pharynx and larynx. In a prospective clinical study 20 patients with a pharyngeal or laryngeal carcinoma were examined with by spiral CT. 80 ml lopromid were intravenously injected as a bolus with a rate of 3 ml/sec. Two consecutive spiral CT scans were performed with start-delay times of 20 and 70 seconds respectively. Delineation and contrast enhancement of tumours, cervical lymph nodes and vessels were evaluated. The radiodensities (HU) of tumors, lymph nodes vessels, pharyngeal wall and muscle were measured. Comparing early and late start delay time scans tumor assessment in the early phase was better in 58%, less in 16% and equal in both scans in 26%. 82% of the pathologic lymph nodes had more peripheral enhancement than surrounding muscle tissue. During the arterial phase the measured radiodensities of the common carotid artery and jugular vein were significantly higher than in the second phase. Contrast-enhanced special CT permits accurate morphologic assessment (size, infiltration) of pharyngeal and supraglottic laryngeal squamous cell carcinoma, while pathologic lymph nodes already have a sufficient contrast enhancement for the detection.
Straatman, Jennifer; Cuesta, Miguel A; Gisbertz, Suzanne S; Van der Peet, Donald L
2014-12-01
Postoperative complications frequently follow major abdominal surgery and are associated with increased morbidity and mortality. Early diagnosis and treatment of complications is associated with improved patient outcome. In this study we assessed the value of a step-up diagnosis plan by C-reactive protein and CT-scan (computed tomography-scan) imaging for detection of postoperative complications following major abdominal surgery.An observational cohort study was conducted of 399 consecutivepatients undergoing major abdominal surgery between January 2009 and January 2011. Indication for operation, type of surgery, postoperative morbidity, complications according to the Clavien-Dindo classification and mortality were recorded. Clinical parameters were recorded until 14 days postoperatively or until discharge. Regular C-reactive protein (CPR) measurements in peripheral blood and on indication -enhanced CT-scans were performed.Eighty-three out of 399 (20.6 %) patients developed a major complication in the postoperative course after a median of seven days (IQR 4-9 days). One hundred and thirty two patients received additional examination consisting of enhanced CT-scan imaging, and treatment by surgical reintervention or intensive care observation. CRP levels were significantly higher in patients with postoperative complications. On the second postoperative dayCRP levels were on average 197.4 mg/L in the uncomplicated group, 220.9 mg/L in patients with a minor complication and 280.1 mg/L in patients with major complications (p < 0,001).CT-scan imaging showed a sensitivity of 91.7 % and specificity of 100 % in diagnosis of major complications. Based on clinical deterioration and the increase of CRP, an additional enhanced CT-scan offered clear discrimination between patients with major abdominal complications and uncomplicated patients. Adequate treatment could then be accomplished.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoven, Andor F. van den, E-mail: a.f.vandenhoven@umcutrecht.nl; Prince, Jip F.; Keizer, Bart de
PurposeTo optimize a C-arm computed tomography (CT) protocol for radioembolization (RE), specifically for extrahepatic shunting and parenchymal enhancement.Materials and MethodsA prospective development study was performed per IDEAL recommendations. A literature-based protocol was applied in patients with unresectable and chemorefractory liver malignancies undergoing an angiography before radioembolization. Contrast and scan settings were adjusted stepwise and repeatedly reviewed in a consensus meeting. Afterwards, two independent raters analyzed all scans. A third rater evaluated the SPECT/CT scans as a reference standard for extrahepatic shunting and lack of target segment perfusion.ResultsFifty scans were obtained in 29 procedures. The first protocol, using a 6 s delaymore » and 10 s scan, showed insufficient parenchymal enhancement. In the second protocol, the delay was determined by timing parenchymal enhancement on DSA power injection (median 8 s, range 4–10 s): enhancement improved, but breathing artifacts increased (from 0 to 27 %). Since the third protocol with a 5 s scan decremented subjective image quality, the second protocol was deemed optimal. Median CNR (range) was 1.7 (0.6–3.2), 2.2 (−1.4–4.0), and 2.1 (−0.3–3.0) for protocol 1, 2, and 3 (p = 0.80). Delineation of perfused segments was possible in 57, 73, and 44 % of scans (p = 0.13). In all C-arm CTs combined, the negative predictive value was 95 % for extrahepatic shunting and 83 % for lack of target segment perfusion.ConclusionAn optimized C-arm CT protocol was developed that can be used to detect extrahepatic shunts and non-perfusion of target segments during RE.« less
Kasai, Takami; Motoori, Ken; Horikoshi, Takuro; Uchiyama, Katsuhiro; Yasufuku, Kazuhiro; Takiguchi, Yuichi; Takahashi, Fumiaki; Kuniyasu, Yoshio; Ito, Hisao
2010-08-01
To evaluate whether dual-time point scanning with integrated fluorine-18 fluorodeoxyglucose ((18)F-FDG) positron emission tomography and computed tomography (PET/CT) is useful for evaluation of mediastinal and hilar lymph nodes in non-small cell lung cancer diagnosed as operable by contrast-enhanced CT. PET/CT data and pathological findings of 560 nodal stations in 129 patients with pathologically proven non-small cell lung cancer diagnosed as operable by contrast-enhanced CT were reviewed retrospectively. Standardized uptake values (SUVs) on early scans (SUVe) 1h, and on delayed scans (SUVd) 2h after FDG injection of each nodal station were measured. Retention index (RI) (%) was calculated by subtracting SUVe from SUVd and dividing by SUVe. Logistic regression analysis was performed with seven kinds of models, consisting of (1) SUVe, (2) SUVd, (3) RI, (4) SUVe and SUVd, (5) SUVe and RI, (6) SUVd and RI, and (7) SUVe, SUVd and RI. The seven derived models were compared by receiver-operating characteristic (ROC) analysis. k-Fold cross-validation was performed with k values of 5 and 10. p<0.05 was considered statistically significant. Model (1) including the term of SUVe showed the largest area under the ROC curve among the seven models. The cut-off probability of metastasis of 3.5% with SUVe of 2.5 revealed a sensitivity of 78% and a specificity of 81% on ROC analysis, and approximately 60% and 80% on k-fold cross-validation. Single scanning of PET/CT is sufficiently useful for evaluating mediastinal and hilar nodes for metastasis. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.
Computed tomography of infantile hepatic hemangioendothelioma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucaya, J.; Enriquez, G.; Amat, L.
1985-04-01
Computed tomography (CT) was performed on five infants with hepatic hemangioendothelioma. Precontrast scans showed solitary or multiple, homogeneous, circumscribed areas with reduced attenuation values. Tiny tumoral calcifications were identified in two patients. Serial scans, after injection of a bolus of contrast material, showed early massive enhancement, which was either diffuse or peripheral. On delayed scans, multinocular tumors became isodense with surrounding liver, while all solitary ones showed varied degrees of centripetal enhancement and persistent central cleftlike unenhanced areas. The authors believe that these CT features are characteristic and obviate arteriographic confirmation.
In vivo differentiation of complementary contrast media at dual-energy CT.
Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F; Gao, Dong-Wei; Yeh, Benjamin M
2012-10-01
To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase-enhanced CT scan simultaneously in a single examination. Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012.
In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT
Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F.; Gao, Dong-Wei
2012-01-01
Purpose: To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Materials and Methods: Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Results: Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase–enhanced CT scan simultaneously in a single examination. Conclusion: Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012 PMID:22778447
Use of gadoxetic acid for computed tomographic cholangiography in healthy dogs.
Chau, Jennifer; Podadera, Juan M; Young, Alex C; Makara, Mariano A
2017-07-01
OBJECTIVE To evaluate the effect of gadoxetic acid (contrast) dose on biliary tract enhancement, determine the optimal time after contrast injection for CT image acquisition, and assess the feasibility of CT cholangiography in sedated dogs. ANIMALS 8 healthy dogs. PROCEDURES The study had 2 parts. In part 1, 4 dogs were anesthetized and underwent CT cholangiography twice. Gadoxetic acid was administered IV at a low dose (0.025 mmol/kg) for the first procedure and high dose (0.3 mmol/kg) for the second procedure. Serial CT scans were obtained at predetermined times after contrast injection. In part 2, 4 dogs were sedated and underwent CT angiography 85 minutes after IV administration of the high contrast dose. Contrast enhancement of the biliary tract on all scans was objectively assessed by measurement of CT attenuation and qualitatively assessed by use of a subjective 4-point scoring system by 3 independent reviewers. All measurements were compared over time and between contrast doses for the dogs of part 1. Subjective measurements were compared between the sedated dogs of part 2 and anesthetized dogs of part 1. RESULTS Enhancement of the biliary tract was positively associated with contrast dose and time after contrast injection. Optimal enhancement was achieved 65 minutes after contrast injection. Subjective visualization of most biliary structures did not differ significantly between sedated and anesthetized dogs. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated CT cholangiography with gadoxetic acid was feasible in sedated dogs. The high contrast dose provided better visualization of biliary structures than the low dose; CT scans should be obtained 65 minutes after contrast injection.
Shimonobo, Toshiaki; Funama, Yoshinori; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, Kazuo
2016-01-01
We used pediatric and adult anthropomorphic phantoms to compare the radiation dose of low- and standard tube voltage chest and abdominal non-contrast-enhanced computed tomography (CT) scans. We also discuss the optimal low tube voltage for non-contrast-enhanced CT. Using a female adult- and three differently-sized pediatric anthropomorphic phantoms we acquired chest and abdominal non-contrast-enhanced scans on a 320-multidetector CT volume scanner. The tube voltage was set at 80-, 100-, and 120 kVp. The tube current was automatically assigned on the CT scanner in response to the set image noise level. On each phantom and at each tube voltage we measured the surface and center dose using high-sensitivity metal-oxide-semiconductor field-effect transistor detectors. The mean surface dose of chest and abdominal CT scans in 5-year olds was 4.4 and 5.3 mGy at 80 kVp, 4.5 and 5.4 mGy at 100 kV, and 4.0 and 5.0 mGy at 120 kVp, respectively. These values were similar in our 3-pediatric phantoms (p > 0.05). The mean surface dose in the adult phantom increased from 14.7 to 19.4 mGy for chest- and from 18.7 to 24.8 mGy for abdominal CT as the tube voltage decreased from 120 to 80 kVp (p < 0.01). Compared to adults, the surface and center dose for pediatric patients is almost the same despite a decrease in the tube voltage and the low tube voltage technique can be used for non-contrast-enhanced chest- and abdominal scanning. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
2014-01-01
Background Contrast-induced acute kidney injury is a common cause of iatrogenic acute kidney injury (AKI). Most of the published estimates of AKI after contrast use originate from the cardiac catheterization literature despite contrast-enhanced computed tomography (CT) scans being the more common setting for contrast use. This systematic review aims to summarize the current evidence about (1)the risk of AKI following intravenous (IV) contrast-enhanced CT scans and(2) the risk of clinical outcomes (i.e. death, hospitalization and need for renal replacement therapy) due to IV contrast-enhanced CT scans. Methods/Design A systematic literature search for published studies will be performed using MEDLINE, EMBASE and The COCHRANE Library databases. Unpublished studies will be identified by searching through grey literature. No language restriction will be applied. The review will consider all studies that have examined the association between IV contrast media and AKI. To be selected, the study should include two arms: one group of exposed patients who received IV contrast material before CT scans and one group of unexposed group who did not receive contrast material before CT scans. Two authors will independently screen titles and abstracts obtained from electronic databases, extract data and will assess the quality of the studies selected using the Cochrane's ‘Risk of Bias’ assessment tool for randomized trials and the Newcastle-Ottawa Scale for observational studies. A random-effects meta-analysis will be performed if there is no remarkable heterogeneity between studies. Discussion This systematic review will provide synthesis of current evidence around the effect of IV contrast material on AKI and other clinical outcomes. Results will be helpful for making evidence-based recommendations and guidelines for clinical and radiologic settings. Systematic review registration PROSPERO CRD42013003799. PMID:25148933
Raju, Prashanth; Sallomi, David; George, Bindu; Patel, Hitesh; Patel, Nikhil; Lloyd, Guy
2012-06-01
To describe the frequency and severity of Aortic valve calcification (AVC) in an unselected cohort of patients undergoing chest CT scanning and to assess the frequency with which AVC was being reported in the radiology reports. Consecutive CT scan images of the chest and the radiological reports (December 2009 to May 2010) were reviewed at the district general hospital (DGH). AVC on CT scan was visually graded on a scale ranging from 0 to IV (0 = no calcification, IV = severe calcification). Total of 416 (232 male; 184 female) CT chest scans [Contrast enhanced 302 (72%), unenhanced 114 (28%)] were reviewed. Mean age was 70.55 ± 11.48 years. AVC in CT scans was identified in 95 of the 416 patients (22.83%). AVC classification was as follows: Grade I: 60 (63.15%), Grade II: 22 (23.15%), Grade III: 9 (9.47%), Grade IV: 4 (4.21%). Only one CT report mentioned AVC. Only 31 of 95 AVC had Transthoracic echocardiogram (TTE). The interval time between CT scan and TTE was variable. Aortic valve calcification in CT chest scans is a common finding and studies have shown that it is strongly related to the presence and severity of aortic valve disease. As CT scans are considered as a valuable additional screening tool for detection of aortic stenosis, AVC should always be commented upon in the radiology reports. Furthermore, patients with at least Grade III and IV AVC should be sent for TTE. © 2012 Blackwell Publishing Ltd.
Martin, C A; Gabrillargues, J; Louvrier, C; Saroul, N; Mom, T; Gilain, L
2014-11-01
This study was designed to analyse the contribution of CT scan to the management of retropharyngeal abscess in children and the place of CT-guided percutaneous aspiration as an alternative to surgical drainage. Retrospective study including 18 children with a mean age of 38 months [range: 5-67 months] presenting with retropharyngeal infection between 2006 and 2011. All cases were initially assessed by contrast-enhanced CT scan of the neck. Clinical, radiological treatment and bacteriological data were collected. Radiological results were correlated with surgical and percutaneous aspiration findings (presence or absence of an abscess). The initial CT scan detected 14 abscesses, 3 cases of non-suppurative lymphadenitis and one case of retropharyngeal oedema. One case of non-suppurative lymphadenitis progressed to abscess after failure of antibiotic therapy and was treated surgically. Surgical drainage revealed a purulent collection in 11 cases and no collection in 3 cases. Four CT-guided percutaneous aspirations were successfully performed. Three cases were treated by antibiotics alone (2 cases of lymphadenitis and 1 case of retropharyngeal oedema). Bacteriological examinations revealed the presence of Streptococcus pyogenes in 78.5% of cases. The positive predictive value of the initial CT scan was 78.8% in our series. Contrast-enhanced neck CT scan confirmed the diagnosis of retropharyngeal abscess and the indication for surgical drainage. It must be performed urgently, on admission. When it is decided to treat the patient with antibiotics alone, follow-up imaging should be performed in the absence of improvement 24 to 48 hours after starting antibiotics. CT-guided percutaneous aspiration is both a diagnostic modality confirming abscess formation of an inflammatory lesion of the retropharyngeal space as well as a therapeutic tool, sometimes avoiding the need for surgical drainage. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Bariatric CT Imaging: Challenges and Solutions.
Fursevich, Dzmitry M; LiMarzi, Gary M; O'Dell, Matthew C; Hernandez, Manuel A; Sensakovic, William F
2016-01-01
The obesity epidemic in the adult and pediatric populations affects all aspects of health care, including diagnostic imaging. With the increasing prevalence of obese and morbidly obese patients, bariatric computed tomographic (CT) imaging is becoming common in day-to-day radiology practice, and a basic understanding of the unique problems that bariatric patients pose to the imaging community is crucial in any setting. Because larger patients may not fit into conventional scanners, having a CT scanner with an adequate table load limit, a large gantry aperture, a large scan field of view, and a high-power generator is a prerequisite for bariatric imaging. Iterative reconstruction methods, high tube current, and high tube voltage can reduce the image noise that is frequently seen in bariatric CT images. Truncation artifacts, cropping artifacts, and ring artifacts frequently complicate the interpretation of CT images of larger patients. If recognized, these artifacts can be easily reduced by using the proper CT equipment, scan acquisition parameters, and postprocessing options. Lastly, because of complex contrast material dynamics, contrast material-enhanced studies of bariatric patients require special attention. Understanding how the rate of injection, the scan timing, and the total mass of iodine affect vascular and parenchymal enhancement will help to optimize contrast-enhanced studies in the bariatric population. This article familiarizes the reader with the challenges that are frequently encountered at CT imaging of bariatric patients, beginning with equipment selection and ending with a review of the most commonly encountered obesity-related artifacts and the technical considerations in the acquisition of contrast-enhanced images. (©)RSNA, 2016.
Malik, Dharmender; Jois, Abhiram; Singh, Harmandeep; Bora, Girdhar S; Basher, Rajender Kumar; Mittal, Bhagwant Rai
2017-09-01
We report a case of 23-year-old man who presented with complaints of progressive abdominal distension for the past 3 months along with the loss of appetite and weight and had a large solid cystic mass in the left half of the abdominal cavity revealed on ultrasonography and contrast-enhanced CT of the abdomen. Subsequent biopsy and histopathology revealed it to be neuroblastoma. Ga-DOTANOC PET/CT scan performed to rule out distant metastasis showed intense radiotracer uptake distributed throughout the skeleton, mimicking a super scan.
Managing vulvovaginal hematoma by arterial embolization as first-line hemostatic therapy.
Takagi, Kenjiro; Akashi, Keiko; Horiuchi, Isao; Nakamura, Eishin; Samejima, Koki; Ushijima, Junko; Okochi, Tomohisa; Hamamoto, Kohei; Tanno, Keisuke
2017-04-01
A puerperal vulvovaginal hematoma may continue to grow after a surgical procedure and may require blood transfusion. Thus, we selected arterial embolization for hemostasis as the first-line management in two cases of large vulvovaginal hematoma. Case 1 was a 32-year-old pregnant woman. After delivery, a 10-cm vulvar hematoma developed. An enhanced computed tomography (CT) scan revealed active bleeding. Arterial embolization was performed and complete hemostasis was obtained. Case 2 was a 34-year-old woman with a recurring hematoma after delivery. An enhanced CT scan revealed extravasation in the hematoma. Gelatin sponges were applied and complete hemostasis was obtained. In both cases, arterial embolization was successful without requiring blood transfusions. We successfully managed two cases of puerperal vulvovaginal hematoma by arterial embolization based on the evaluation of an enhanced CT scan. In conclusion, we suggest arterial embolization to be a viable option for first-line treatment in the management of vulvovaginal hematomas. Copyright © 2017. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Shahzad, Rahil; Bos, Daniel; Budde, Ricardo P. J.; Pellikaan, Karlijn; Niessen, Wiro J.; van der Lugt, Aad; van Walsum, Theo
2017-05-01
Early structural changes to the heart, including the chambers and the coronary arteries, provide important information on pre-clinical heart disease like cardiac failure. Currently, contrast-enhanced cardiac computed tomography angiography (CCTA) is the preferred modality for the visualization of the cardiac chambers and the coronaries. In clinical practice not every patient undergoes a CCTA scan; many patients receive only a non-contrast-enhanced calcium scoring CT scan (CTCS), which has less radiation dose and does not require the administration of contrast agent. Quantifying cardiac structures in such images is challenging, as they lack the contrast present in CCTA scans. Such quantification would however be relevant, as it enables population based studies with only a CTCS scan. The purpose of this work is therefore to investigate the feasibility of automatic segmentation and quantification of cardiac structures viz whole heart, left atrium, left ventricle, right atrium, right ventricle and aortic root from CTCS scans. A fully automatic multi-atlas-based segmentation approach is used to segment the cardiac structures. Results show that the segmentation overlap between the automatic method and that of the reference standard have a Dice similarity coefficient of 0.91 on average for the cardiac chambers. The mean surface-to-surface distance error over all the cardiac structures is 1.4+/- 1.7 mm. The automatically obtained cardiac chamber volumes using the CTCS scans have an excellent correlation when compared to the volumes in corresponding CCTA scans, a Pearson correlation coefficient (R) of 0.95 is obtained. Our fully automatic method enables large-scale assessment of cardiac structures on non-contrast-enhanced CT scans.
Faure, Marguerite E; Swart, Laurens E; Dijkshoorn, Marcel L; Bekkers, Jos A; van Straten, Marcel; Nieman, Koen; Parizel, Paul M; Krestin, Gabriel P; Budde, Ricardo P J
2018-05-01
Multidetector CT (MDCT) is a valuable tool for functional prosthetic heart valve (PHV) assessment. However, radiation exposure remains a concern. We assessed a novel CT-acquisition protocol for comprehensive PHV evaluation at limited dose. Patients with a PHV were scanned using a third-generation dual-source CT scanner (DSCT) and iterative reconstruction technique (IR). Three acquisitions were obtained: a non-enhanced scan; a contrast-enhanced, ECG-triggered, arterial CT angiography (CTA) scan with reconstructions at each 5 % of the R-R interval; and a delayed high-pitch CTA of the entire chest. Image quality was scored on a five-point scale. Radiation dose was obtained from the reported CT dose index (CTDI) and dose length product (DLP). We analysed 43 CT examinations. Mean image quality score was 4.1±1.4, 4.7±0.5 and 4.2±0.6 for the non-contrast-enhanced, arterial and delayed acquisitions, respectively, with a total mean image quality of 4.3±0.7. Mean image quality for leaflet motion was 3.9±1.4. Mean DLP was 28.2±17.1, 457.3±168.6 and 68.5±47.2 mGy.cm for the non-contrast-enhanced (n=40), arterial (n=43) and delayed acquisition (n=43), respectively. The mean total DLP was 569±208 mGy.cm and mean total radiation dose was 8.3±3.0 mSv (n=43). Comprehensive assessment of PHVs is possible using DSCT and IR at moderate radiation dose. • Prosthetic heart valve dysfunction is a potentially life-threatening condition. • Dual-source CT can adequately assess valve leaflet motion and anatomy. • We assessed a comprehensive protocol with three acquisitions for PHV evaluation. • This protocol is associated with good image quality and limited dose.
Bashir, Mustafa R; Weber, Paul W; Husarik, Daniela B; Howle, Laurens E; Nelson, Rendon C
2012-08-01
To assess whether a scan triggering technique based on the slope of the time-attenuation curve combined with table speed optimization may improve arterial enhancement in aortic CT angiography compared to conventional threshold-based triggering techniques. Measurements of arterial enhancement were performed in a physiologic flow phantom over a range of simulated cardiac outputs (2.2-8.1 L/min) using contrast media boluses of 80 and 150 mL injected at 4 mL/s. These measurements were used to construct computer models of aortic attenuation in CT angiography, using cardiac output, aortic diameter, and CT table speed as input parameters. In-plane enhancement was calculated for normal and aneurysmal aortic diameters. Calculated arterial enhancement was poor (<150 HU) along most of the scan length using the threshold-based triggering technique for low cardiac outputs and the aneurysmal aorta model. Implementation of the slope-based triggering technique with table speed optimization improved enhancement in all scenarios and yielded good- (>200 HU; 13/16 scenarios) to excellent-quality (>300 HU; 3/16 scenarios) enhancement in all cases. Slope-based triggering with table speed optimization may improve the technical quality of aortic CT angiography over conventional threshold-based techniques, and may reduce technical failures related to low cardiac output and slow flow through an aneurysmal aorta.
Kumar, Arvind; Jindal, Tarun; Dutta, Roman; Kumar, Rakesh
2009-10-01
To evaluate the role of combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in differentiating bronchial tumors observed in contrast enhanced computed tomography scan of chest. Prospective observational study. Place of study: All India Institute of Medical Sciences, New Delhi, India. 7 patients with bronchial mass detected in computed tomography scan of the chest were included in this study. All patients underwent (18)F-FDG PET-CT scan, (68)Ga DOTA-TOC PET-CT scan and fiberoptic bronchoscope guided biopsy followed by definitive surgical excision. The results of functional imaging studies were analyzed and the results are correlated with the final histopathology of the tumor. Histopathological examination of 7 bronchial masses revealed carcinoid tumors (2 typical, 1 atypical), inflammatory myofibroblastic tumor (1), mucoepidermoid carcinoma (1), hamartoma (1), and synovial cell sarcoma (1). The typical carcinoids had mild (18)F-FDG uptake and high (68)Ga DOTA-TOC uptake. Atypical carcinoid had moderate uptake of (18)F-FDG and high (68)Ga DOTA-TOC uptake. Inflammatory myofibroblastic tumor showed high uptake of (18)F-FDG and no uptake of (68)Ga DOTA-TOC. Mucoepidermoid carcinoma showed mild (18)F-FDG uptake and no (68)Ga DOTA-TOC uptake. Hamartoma showed no uptake on either scans. Synovial cell sarcoma showed moderate (18)F-FDG uptake and mild focal (68)Ga DOTA-TOC uptake. This initial experience with the combined use of (18)F-FDG and (68)Ga DOTA-TOC PET-CT scan reveals different uptake patterns in various bronchial tumors. Bronchoscopic biopsy will continue to be the gold standard; however, the interesting observations made in this study merits further evaluation of the utility of the combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in larger number of patients with bronchial masses.
Woo, Seung Hoon; Choi, Dae-Seob; Kim, Jin-pyeong; Park, Jung Je; Joo, Yeon Hee; Chung, Phil-Sang; Kim, Bo-Young; Ko, Young-Hyeh; Jeong, Han-Sin; Kim, Hyung-Jin
2013-01-01
The objective of this study was to define the radiological characteristics of 2-phase computed tomography (CT) of parotid gland Warthin tumors (WTs) with a pathologic basis for these findings. We prospectively enrolled 116 patients with parotid gland tumor who underwent preoperative 2-phase CT scans(scanning delays of 30 and 120 seconds). The attenuation changes and enhancement patterns were analyzed according to pathology. We also evaluated size-matched samples of WTs and pleomorphic adenoma by staining CD31, vascular endothelial growth factor-receptor 2, collagen IV, and smooth muscle actin. Computed tomography numbers in WTs were significantly higher than those in other tumors in early-phase scans and lower in delayed scans. Pathologically, CD31(+) blood vessel area was significantly higher in WTs than in pleomorphic adenomas. In addition, WTs had an extensive capillary network and many leaky blood vessels. The enhancement pattern of early fill-in and early washout is the typical finding of WTs on 2-phase CT scans, which may be attributed pathologically to abundant blood vessel and extensive capillary network.
2012-01-01
Background Computed tomography (CT) scanning has become essential in the early diagnostic phase of trauma care because of its high diagnostic accuracy. The introduction of multi-slice CT scanners and infrastructural improvements made total-body CT scanning technically feasible and its usage is currently becoming common practice in several trauma centers. However, literature provides limited evidence whether immediate total-body CT leads to better clinical outcome then conventional radiographic imaging supplemented with selective CT scanning in trauma patients. The aim of the REACT-2 trial is to determine the value of immediate total-body CT scanning in trauma patients. Methods/design The REACT-2 trial is an international, multicenter randomized clinical trial. All participating trauma centers have a multi-slice CT scanner located in the trauma room or at the Emergency Department (ED). All adult, non-pregnant, severely injured trauma patients according to predefined criteria will be included. Patients in whom direct scanning will hamper necessary cardiopulmonary resuscitation or who require an immediate operation because of imminent death (both as judged by the trauma team leader) are excluded. Randomization will be computer assisted. The intervention group will receive a contrast-enhanced total-body CT scan (head to pelvis) during the primary survey. The control group will be evaluated according to local conventional trauma imaging protocols (based on ATLS guidelines) supplemented with selective CT scanning. Primary outcome will be in-hospital mortality. Secondary outcomes are differences in mortality and morbidity during the first year post trauma, several trauma work-up time intervals, radiation exposure, general health and quality of life at 6 and 12 months post trauma and cost-effectiveness. Discussion The REACT-2 trial is a multicenter randomized clinical trial that will provide evidence on the value of immediate total-body CT scanning during the primary survey of severely injured trauma patients. If immediate total-body CT scanning is found to be the best imaging strategy in severely injured trauma patients it could replace conventional imaging supplemented with CT in this specific group. Trial Registration ClinicalTrials.gov: (NCT01523626). PMID:22458247
CT manifestations of peritoneal carcinomatosis.
Walkey, M M; Friedman, A C; Sohotra, P; Radecki, P D
1988-05-01
Seventy-three abdominopelvic contrast-enhanced CT scans obtained in 60 patients with peritoneal tumor spread were reviewed retrospectively to determine the CT signs of peritoneal malignancy. Ascites was present in 54 studies (74%) and was the most common CT finding. Loculation of the fluid occurred in 25 (46%) of these. In nine (17%) of the 54, a new finding, absence of cul-de-sac fluid in the presence of generalized ascites, was noted. Parietal peritoneal thickening with contrast enhancement of the peritoneum, making the peritoneum visible as a thin line along the abdominal wall, was present in 45 (62%) of studies. This is believed to represent confluent peritoneal metastases. Small-bowel involvement was present in half of the cases (wall thickening and irregularity with or without obstruction). Tumor involvement of the omentum was visible as soft-tissue permeation of fat, enhancing nodules, and/or an omental cake. Of the 26 patients without a previously known malignancy, identification of the primary tumor in addition to peritoneal carcinomatosis was possible in 13 (50%). Appreciation of the spectrum of CT findings in peritoneal carcinomatosis is essential for accurate evaluation of scans in patients with abdominopelvic malignancies.
Delayed splenic vascular injury after nonoperative management of blunt splenic trauma.
Furlan, Alessandro; Tublin, Mitchell E; Rees, Mitchell A; Nicholas, Dederia H; Sperry, Jason L; Alarcon, Louis H
2017-05-01
Delayed splenic vascular injury (DSVI) is traditionally considered a rare, often clinically occult, harbinger of splenic rupture in patients with splenic trauma that are managed conservatively. The purpose of our study was to assess the incidence of DSVI and associated features in patients admitted with blunt splenic trauma and managed nonoperatively. A retrospective analysis was conducted over a 4-y time. Patients admitted with blunt splenic trauma, managed no-operatively and with a follow-up contrast-enhanced computed tomography (CT) scan study during admission were included. The CT scans were reviewed for American Association for the Surgery of Trauma splenic injury score, amount of hemoperitoneum, and presence of DSVI. Logistic regression models were used to investigate the risk factors associated with DSVI. A total of 100 patients (60 men and 40 women) constituted the study group. Follow-up CT scan demonstrated a 23% incidence of DSVI. Splenic artery angiography validated DSVI in 15% of the total patient population. Most DSVIs were detected only on arterial phase CT scan imaging. The American Association for the Surgery of Trauma splenic injury score (odds ratio = 1.73; P = 0.045) and the amount of hemoperitoneum (odds ratio = 1.90; P = 0.023) on admission CT scan were associated with the development of DSVI on follow-up CT scan. DSVI on follow-up CT scan imaging of patients managed nonoperatively after splenic injury is common and associated with splenic injury score assessed on admission CT scan. Copyright © 2016 Elsevier Inc. All rights reserved.
Advantages and limitations of computed tomography scans for treatment planning of lung cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mira, J.G.; Potter, J.L.; Fullerton, G.D.
1982-09-01
Forty-five Chest computed tomography (CT) scans performed on patients with lung carcinoma (LC) were evaluated in an attempt to understand the pattern of intrathoracic tumor spread and the advantages and limitations this technique offers for treatment planning when compared to planning done by conventional X rays. The following findings can help treatment planning. (1) When regular X rays do not show location (i.e., hemithorax opacification), CT scan will show it in 68% of patients. If regular X rays show a well localized mass, unsuspected tumor extensions were disclosed in 78% of these patients. Hence, CT scans should be done inmore » all LC patients prior to treatment planning; (2) Mediastinal masses frequently spread anteriorly toward the sternum and posteriorly around the vertebral bodies toward the cord and costal pleura. This should be considered for radiotherapy boost techniques; (3) Lung masses spread in one third of cases toward the lateral costal pleura. Thus, the usual 1-2cm of safety margin around the LC are not sufficient in some cases; (4) Tumor size can appear much smaller in regular X rays than in CT scans. Hence, CT scans are necessary for accurate staging and evaluation of tumor response. Some CT scan limitations are: (1) Atelectasis blends with tumor in approximately half of the patients, thus obscuring tumor boundaries; (2) CT numbers and contrast enhancement did not help to differentiate between these two structures; and (3) Limited definition of CT scan prevents investigation of suspected microscopic spread around tumor masses.« less
Hybrid detection of lung nodules on CT scan images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Lin; Tan, Yongqiang; Schwartz, Lawrence H.
Purpose: The diversity of lung nodules poses difficulty for the current computer-aided diagnostic (CAD) schemes for lung nodule detection on computed tomography (CT) scan images, especially in large-scale CT screening studies. We proposed a novel CAD scheme based on a hybrid method to address the challenges of detection in diverse lung nodules. Methods: The hybrid method proposed in this paper integrates several existing and widely used algorithms in the field of nodule detection, including morphological operation, dot-enhancement based on Hessian matrix, fuzzy connectedness segmentation, local density maximum algorithm, geodesic distance map, and regression tree classification. All of the adopted algorithmsmore » were organized into tree structures with multi-nodes. Each node in the tree structure aimed to deal with one type of lung nodule. Results: The method has been evaluated on 294 CT scans from the Lung Image Database Consortium (LIDC) dataset. The CT scans were randomly divided into two independent subsets: a training set (196 scans) and a test set (98 scans). In total, the 294 CT scans contained 631 lung nodules, which were annotated by at least two radiologists participating in the LIDC project. The sensitivity and false positive per scan for the training set were 87% and 2.61%. The sensitivity and false positive per scan for the testing set were 85.2% and 3.13%. Conclusions: The proposed hybrid method yielded high performance on the evaluation dataset and exhibits advantages over existing CAD schemes. We believe that the present method would be useful for a wide variety of CT imaging protocols used in both routine diagnosis and screening studies.« less
Hwang, Eui Jin; Shin, Cheong-Il; Choi, Young Hun; Park, Chang Min
2018-06-06
To evaluate the frequency, outcome, and risk factors of intravenous contrast media (CM) extravasation during contrast-enhanced CT scans in a large population. After institutional review board approval, 142,651 patients (72,976 males and 69,675 females; mean age, 59.9 ± 13.0 years) who underwent contrast-enhanced CT scans with intravenous CM between January 2015 and April 2017 were retrospectively included. The frequency of CM extravasations and their clinical outcomes were investigated. Risk factors of CM extravasation were evaluated using logistic regression with generalized estimating equation analyses. In addition, the frequency and risk factors of large-volume (≥100 ml) CM extravasation were also investigated. CM extravasation occurred in 0.23% (321/142,651) of patients, all of which were of mild degree and resolved without any sequelae through conservative management. Multivariate analysis revealed that female gender [odds ratio (OR) = 1.61; p < 0.001], 60 < age ≤ 70 years (OR = 1.71; p = 0.004) or age > 70 years (OR = 2.49; p < 0.001), patients in general wards (OR = 2.71; p < 0.001) or ICUs (OR = 4.76; p < 0.001), 9.4 < CM viscosity ≤ 10.0 (OR = 1.65; p = 0.015), 10.0 < CM viscosity ≤ 10.6 (OR = 1.60; p = 0.002), and CM viscosity > 16.0 (OR = 2.55, p < 0.001) were independent risk factors for CM extravasation. CM extravasation during contrast-enhanced CT scans was uncommon with no substantial clinical consequences. Several risk factors that may have the potential to reduce the occurrence of CM extravasation were identified. • The observed frequency of contrast media extravasation during contrast-enhanced CT scans was 0.23% (321/142,651). • Significant risk factors for contrast media extravasation were female gender, age older than 60 years, patients in general wards or ICUs, and the viscosity of contrast media greater than 9.4 mPa∙s. • The main preventive action for contrast media extravasation would be to lower the viscosity of contrast media.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Victor Ho Fun, E-mail: vhflee@hku.hk; Ng, Sherry Chor Yi; Kwong, Dora Lai Wan
The aim of this study was to investigate if intravenous contrast injection affected the radiation doses to carotid arteries and thyroid during intensity-modulated radiation therapy (IMRT) planning for nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC underwent plain computed tomography (CT) followed by repeated scanning after contrast injection. Carotid arteries (common, external, internal), thyroid, target volumes, and other organs-at-risk (OARs), as well as IMRT planning, were based on contrast-enhanced CT (CE-CT) images. All these structures and the IMRT plans were then copied and transferred to the non–contrast-enhanced CT (NCE-CT) images, and dose calculation without optimization was performed again. The radiationmore » doses to the carotid arteries and the thyroid based on CE-CT and NCE-CT were then compared. Based on CE-CT, no statistical differences, despite minute numeric decreases, were noted in all dosimetric parameters (minimum, maximum, mean, median, D05, and D01) of the target volumes, the OARs, the carotid arteries, and the thyroid compared with NCE-CT. Our results suggested that compared with NCE-CT planning, CE-CT scanning should be performed during IMRT for better target and OAR delineation, without discernible change in radiation doses.« less
Tang, Hui; Yu, Nan; Jia, Yongjun; Yu, Yong; Duan, Haifeng; Han, Dong; Ma, Guangming; Ren, Chenglong; He, Taiping
2018-01-01
To evaluate the image quality improvement and noise reduction in routine dose, non-enhanced chest CT imaging by using a new generation adaptive statistical iterative reconstruction (ASIR-V) in comparison with ASIR algorithm. 30 patients who underwent routine dose, non-enhanced chest CT using GE Discovery CT750HU (GE Healthcare, Waukesha, WI) were included. The scan parameters included tube voltage of 120 kVp, automatic tube current modulation to obtain a noise index of 14HU, rotation speed of 0.6 s, pitch of 1.375:1 and slice thickness of 5 mm. After scanning, all scans were reconstructed with the recommended level of 40%ASIR for comparison purpose and different percentages of ASIR-V from 10% to 100% in a 10% increment. The CT attenuation values and SD of the subcutaneous fat, back muscle and descending aorta were measured at the level of tracheal carina of all reconstructed images. The signal-to-noise ratio (SNR) was calculated with SD representing image noise. The subjective image quality was independently evaluated by two experienced radiologists. For all ASIR-V images, the objective image noise (SD) of fat, muscle and aorta decreased and SNR increased along with increasing ASIR-V percentage. The SD of 30% ASIR-V to 100% ASIR-V was significantly lower than that of 40% ASIR (p < 0.05). In terms of subjective image evaluation, all ASIR-V reconstructions had good diagnostic acceptability. However, the 50% ASIR-V to 70% ASIR-V series showed significantly superior visibility of small structures when compared with the 40% ASIR and ASIR-V of other percentages (p < 0.05), and 60% ASIR-V was the best series of all ASIR-V images, with a highest subjective image quality. The image sharpness was significantly decreased in images reconstructed by 80% ASIR-V and higher. In routine dose, non-enhanced chest CT, ASIR-V shows greater potential in reducing image noise and artefacts and maintaining image sharpness when compared to the recommended level of 40%ASIR algorithm. Combining both the objective and subjective evaluation of images, non-enhanced chest CT images reconstructed with 60% ASIR-V have the highest image quality. Advances in knowledge: This is the first clinical study to evaluate the clinical value of ASIR-V in the same patients using the same CT scanner in the non-enhanced chest CT scans. It suggests that ASIR-V provides the better image quality and higher diagnostic confidence in comparison with ASIR algorithm.
Liu, Zhimin; Song, Lei; Yu, Tong; Gao, Jun; Zhang, Qifeng; Jiang, Ling; Liu, Yong; Peng, Yun
2016-09-01
The aim of this study was to explore the feasibility of using low dose radiation and low concentration contrast media in enhanced CT examinations in children with congenital heart disease. Ninety patients with congenital heart disease were randomly divided into three groups of 30 patients each who underwent contrast-enhanced cardiac scans on a Discovery CT750 HD scanner. Group A received 270 mg I/mL iodixanol, and group B received 320 mg I/mL iodixanol contrast media and was scanned with prospective ECG triggering mode. Group C received 320 mg I/mL iodixanol and was scanned with conventional retrospective ECG gating mode. The same weight-based contrast injection protocol was used for all three groups. Images were reconstructed using a 30% adaptive statistical iterative reconstruction (ASIR) algorithm and a 50% ASIR in groups A and B and a 30% ASIR in group C. The subjective and objective image quality evaluations, diagnostic accuracies, radiation doses and amounts of contrast media in the three groups were measured and compared. All images in the three groups met the diagnostic requirements, with the same diagnostic accuracy and image quality scores greater than 3 in a 4-point scoring system. However, ventricular enhancement and the objective noise, signal-to-noise ratio, contrast-to-noise ratio and subjective image quality scores in group C were better than those in groups A and B (all P<.001). The effective radiation dose in groups A and B was 84% lower than that in group C (P<.001); group A received the lowest contrast dose (14% lower than that of groups B and C). Enhanced CT scan images with low dose radiation and low concentration contrast media can meet the diagnostic requirements for examining children with congenital heart disease while reducing the potential risk of radiation damage and contrast-induced nephropathy. © 2016 John Wiley & Sons Ltd.
Rupp, Jordan D; Ferre, Robinson M; Boyd, Jeremy S; Dearing, Elizabeth; McNaughton, Candace D; Liu, Dandan; Jarrell, Kelli L; McWade, Conor M; Self, Wesley H
2016-08-01
Ultrasound-guided intravenous catheter (USGIV) insertion is increasingly being used for administration of intravenous (IV) contrast for computed tomography (CT) scans. The goal of this investigation was to evaluate the risk of contrast extravasation among patients receiving contrast through USGIV catheters. A retrospective observational study of adult patients who underwent a contrast-enhanced CT scan at a tertiary care emergency department during a recent 64-month period was conducted. The unadjusted prevalence of contrast extravasation was compared between patients with an USGIV and those with a standard peripheral IV inserted without ultrasound. Then, a two-stage sampling design was used to select a subset of the population for a multivariable logistic regression model evaluating USGIVs as a risk factor for extravasation while adjusting for potential confounders. In total, 40,143 patients underwent a contrasted CT scan, including 364 (0.9%) who had contrast administered through an USGIV. Unadjusted prevalence of extravasation was 3.6% for contrast administration through USGIVs and 0.3% for standard IVs (relative risk = 13.9, 95% confidence interval [CI] = 7.9 to 24.6). After potential confounders were adjusted for, CT contrast administered through USGIVs was associated with extravasation (adjusted odds ratio = 8.6, 95% CI = 4.6 to 16.2). No patients required surgical management for contrast extravasation; one patient in the standard IV group was admitted for observation due to extravasation. Patients who received contrast for a CT scan through an USGIV had a higher risk of extravasation than those who received contrast through a standard peripheral IV. Clinicians should consider this extravasation risk when weighing the risks and benefits of a contrast-enhanced CT scan in a patient with USGIV vascular access. © 2016 by the Society for Academic Emergency Medicine.
Rupp, Jordan D.; Ferre, Robinson M.; Boyd, Jeremy S.; Dearing, Elizabeth; McNaughton, Candace D.; Liu, Dandan; Jarrell, Kelli L.; McWade, Conor M.; Self, Wesley H.
2016-01-01
Objective Ultrasound guided intravenous catheter (USGIV) insertion is increasingly being used for administration of intravenous contrast for computed tomography (CT) scans. The goal of this investigation was to evaluate the risk of contrast extravasation among patients receiving contrast through USGIV catheters. Methods A retrospective observational study of adult patients who underwent a contrast-enhanced CT scan at a tertiary-care emergency department during a recent 64-month period was conducted. The unadjusted prevalence of contrast extravasation was compared between patients with an USGIV and those with a standard peripheral IV inserted without ultrasound. Then, a two-stage sampling design was used to select a subset of the population for a multivariable logistic regression model evaluating USGIVs as a risk factor for extravasation while adjusting for potential confounders. Results In total, 40,143 patients underwent a contrasted CT scan, including 364 (0.9%) who had contrast administered through an USGIV. Unadjusted prevalence of extravasation was 3.6% for contrast administration through USGIVs and 0.3% for standard IVs (relative risk: 13.9, 95% CI: 7.7 to 24.6). After adjustment for potential confounders, CT contrast administered through USGIVs was associated with extravasation (adjusted odds ratio: 8.6; 95% CI: 4.6, 16.2). No patients required surgical management for contrast extravasation; one patient in the standard IV group was admitted for observation due to extravasation. Conclusions Patients who received contrast for a CT scan through an USGIV had a higher risk of extravasation than those who received contrast through a standard peripheral IV. Clinicians should consider this extravasation risk when weighing the risks and benefits of a contrast-enhanced CT scan in a patient with USGIV vascular access. PMID:27151898
Kim, Sang; Kunkel, Scott; Browske, Kristin
2018-01-01
Anomalies of the inferior vena cava (AIVC) are rare but well-recognized anatomic abnormalities that can lead to clinically significant deep vein thrombosis (DVT) in a subset of otherwise healthy patients. This report illustrates an uncommon congenital anomaly that military clinicians should consider when evaluating unprovoked DVT in young patients. Single case report and literature review. We describe a case of a 24-yr-old United States Marine who presented with abdominal pain for 2 wk. After conservative therapy failed, a contrast-enhanced abdominal computed tomography (CT) scan was performed. The CT scan revealed an absent inferior vena cava with evidence of right venous thrombophlebitis. We include four contrast-enhanced helical CT scans that illustrate this phenomenon. Due to the lack of available studies and data, we do not know the relative risk of DVT in patients with AIVC. However, the literature review suggests that there is a pro-thrombogenic effect of this congenital anomaly. Clinicians should include AIVC in their differential when treating young, otherwise healthy patients with unprovoked DVT. This population is much more likely to have an AIVC than the general population. In addition to thrombophilia markers, a contrast-enhanced CT scan should be considered as part of the initial workup. Published by Oxford University Press on behalf of the Association of Military Surgeons of the United States 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Ohno, Yoshiharu; Seki, Shinichiro; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Takenaka, Daisuke; Kassai, Yoshimori; Yui, Masao; Sugimura, Kazuro
2015-08-01
To compare predictive capabilities of non-contrast-enhanced (CE)- and dynamic CE-perfusion MRIs, thin-section multidetector computed tomography (CT) (MDCT), and perfusion scan for postoperative lung function in non-small cell lung cancer (NSCLC) patients. Sixty consecutive pathologically diagnosed NSCLC patients were included and prospectively underwent thin-section MDCT, non-CE-, and dynamic CE-perfusion MRIs and perfusion scan, and had their pre- and postoperative forced expiratory volume in one second (FEV1 ) measured. Postoperative percent FEV1 (po%FEV1 ) was then predicted from the fractional lung volume determined on semiquantitatively assessed non-CE- and dynamic CE-perfusion MRIs, from the functional lung volumes determined on quantitative CT, from the number of segments observed on qualitative CT, and from uptakes detected on perfusion scans within total and resected lungs. Predicted po%FEV1 s were then correlated with actual po%FEV1 s, which were %FEV1 s measured postoperatively. The limits of agreement were also determined. All predicted po%FEV1 s showed significant correlation (0.73 ≤ r ≤ 0.93, P < 0.0001) and limits of agreement with actual po%FEV1 (non-CE-perfusion MRI: 0.3 ± 10.0%, dynamic CE-perfusion MRI: 1.0 ± 10.8%, perfusion scan: 2.2 ± 14.1%, quantitative CT: 1.2 ± 9.0%, qualitative CT: 1.5 ± 10.2%). Non-CE-perfusion MRI may be able to predict postoperative lung function more accurately than qualitatively assessed MDCT and perfusion scan. © 2014 Wiley Periodicals, Inc.
High pitch third generation dual-source CT: Coronary and Cardiac Visualization on Routine Chest CT
Sandfort, Veit; Ahlman, Mark; Jones, Elizabeth; Selwaness, Mariana; Chen, Marcus; Folio, Les; Bluemke, David A.
2016-01-01
Background Chest CT scans are frequently performed in radiology departments but have not previously contained detailed depiction of cardiac structures. Objectives To evaluate myocardial and coronary visualization on high-pitch non-gated CT of the chest using 3rd generation dual-source computed tomography (CT). Methods Cardiac anatomy of patients who had 3rd generation, non-gated high pitch contrast enhanced chest CT and who also had prior conventional (low pitch) chest CT as part of a chest abdomen pelvis exam was evaluated. Cardiac image features were scored by reviewers blinded to diagnosis and pitch. Paired analysis was performed. Results 3862 coronary segments and 2220 cardiac structures were evaluated by two readers in 222 CT scans. Most patients (97.2%) had chest CT for oncologic evaluation. The median pitch was 2.34 (IQR 2.05, 2.65) in high pitch and 0.8 (IQR 0.8, 0.8) in low pitch scans (p<0.001). High pitch CT showed higher image visualization scores for all cardiovascular structures compared with conventional pitch scans (p<0.0001). Coronary arteries were visualized in 9 coronary segments per exam in high pitch scans versus 2 segments for conventional pitch (p<0.0001). Radiation exposure was lower in the high pitch group compared with the conventional pitch group (median CTDIvol 10.83 vs. 12.36 mGy and DLP 790 vs. 827 mGycm respectively, p <0.01 for both) with comparable image noise (p=0.43). Conclusion Myocardial structure and coronary arteries are frequently visualized on non-gated 3rd generation chest CT. These results raise the question of whether the heart and coronary arteries should be routinely interpreted on routine chest CT that is otherwise obtained for non-cardiac indications. PMID:27133589
The promise of dynamic contrast-enhanced imaging in radiation therapy.
Cao, Yue
2011-04-01
Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and computed tomography (CT) scanning are emerging as valuable tools to quantitatively map the spatial distribution of vascular parameters, such as perfusion, vascular permeability, blood volume, and mean transit time in tumors and normal organs. DCE MRI/CT have shown prognostic and predictive value for response of certain cancers to chemotherapy and radiation therapy. DCE MRI/CT offer the promise of early assessment of tumor response to radiation therapy, opening a window for adaptively optimizing radiation therapy based upon functional alterations that occur earlier than morphologic changes. DCE MRI/CT has also shown the potential of mapping dose responses in normal organs and tissue for evaluation of individual sensitivity to radiation, providing additional opportunities to minimize risks of radiation injury. The evidence for potentially applying DCE MRI and CT for selection and delineation of radiation boost targets is growing. The clinical use of DCE MRI and CT scanning as a biomarker or even a surrogate endpoint for radiation therapy assessment of tumor and normal organs must consider technical validation issues, including standardization, reproducibility, accuracy and robustness, and clinical validation of the sensitivity and specificity for each specific problem of interest. Although holding great promise, to date, DCE MRI and CT scanning have not been qualified as a surrogate endpoint for radiation therapy assessment or for treatment modification in any prospective phase III clinical trial for any tumor site. Copyright © 2011 Elsevier Inc. All rights reserved.
Benedetti, Nancy; Aslam, Rizwan; Wang, Zhen J.; Joe, Bonnie N.; Fu, Yanjun; Yee, Judy; Yeh, Benjamin M.
2010-01-01
OBJECTIVE The objective of our study was to determine the prevalence and clinical predictors of delayed contrast enhancement of ascites. MATERIALS AND METHODS In this retrospective study, 132 consecutive patients with ascites who underwent repeated abdominopelvic CT examinations performed within 7 days of each other were identified. These patients included 112 patients who received and 20 who did not receive IV contrast material at the initial CT examination. For each examination, we recorded the CT attenuation of the ascites. For the follow-up scan, the presence of delayed enhancement of ascites was defined as an increase in CT attenuation > 10 HU over baseline. The Fisher’s exact test, unpaired Student’s t test, and logistic regression were used to determine predictors of delayed enhancement of ascites. RESULTS A threshold increase in the attenuation of ascites by > 10 HU or more between the initial and follow-up CT examinations occurred only when IV contrast material was given with the initial examination. The increased attenuation was due to delayed contrast enhancement of ascites and occurred in 15 of the 112 patients (13%). Of the 16 patients scanned less than 1 day apart, 10 (63%) showed delayed enhancement of ascites. Delayed enhancement was not observed 3 or more days after IV contrast material administration. For each 1 mg/dL increase in serum creatinine level, the likelihood of delayed enhancement of ascites increased (odds ratio, 2.02; 95% CI, 1.11–3.69). Multivariate logistic regression showed that a short time interval between examinations (p < 0.001), increased serum creatinine level (p < 0.001), and presence of loculated ascites (p = < 0.01) were independent predictors of the magnitude of delayed enhancement of ascites. CONCLUSION Delayed contrast enhancement of ascites occurs commonly after recent prior IV contrast material administration and should not be mistaken for hemoperitoneum or proteinaceous fluid such as pus. PMID:19696286
Caruso, Riccardo; Pesce, Alessandro; Martines, Valentina
2017-10-01
The patient is a 79-year-old male, suffering from advanced metastatic prostate cancer, who developed a progressively worsening ideomotor slowing and was therefore referred to the emergency department of our institution. A plain axial computed tomography (CT) scan revealed a vast hemispheric subdural fluid collection, apparently a subdural hematoma. On closer inspection, and most of all, in hindsight, a tenuously isohyperdense signal irregularity at the frontal aspect of the fluid collection appears. Because of the declined general medical conditions and the paucity of the neurologic impairment, a high-dose, corticosteroid-based conservative strategy was performed. The total body CT scan for the routine oncologic follow-up of the prostate cancer scan fell at 20 days from the first CT of the emergency department. A second contrast-enhanced axial CT scan demonstrated the presence of 2 subdural metastases, presumably the initial pathogenesis of the subdural fluid collection. Copyright © 2017 Elsevier Inc. All rights reserved.
[Diagnosis of strangulated Spiegel hernia based on CT scan: about a case].
Akpo, Geraud; Deme, Hamidou; Badji, Nfally; Niang, Fallou; Toure, Mohamadou; Niang, Ibrahima; Diouf, Malick; Niang, El Hadj
2016-01-01
We report a case of a 86-year old woman with Spiegel hernia complicated by occlusion whose diagnosis was based on CT scan. She was examined in the Emergency Surgery Department for brutal onset of pain in the right iliac fossa associated with vomiting. On physical examination the patient was febrile (38.2° C). It showed hard, sensitive and mobile mass located in the right iliac fossa, with respect to both planes. Abdominal CT scan showed a hernia sac with the neck measuring 13 mm in the right iliac fossa, in front of the aponeurosis of the external oblique muscle. It contained fat and a small bowel loop (curved arrow) with two zones of transition giving a double beak-like appearance at the level of the neck. CT scan showed a lack of enhancement of the wall of the loop after administration of contrast material. The diagnosis of strangulated spiegel hernia associated with sign of arterial ischemia of the digestive wall was retained. Surgery was perfomed with simple postoperative management.
Conley, David B.; Tan, Bruce; Bendok, Bernard R.; Batjer, H. Hunt; Chandra, Rakesh; Sidle, Douglas; Rahme, Rudy J.; Adel, Joseph G.; Fishman, Andrew J.
2011-01-01
Precise and safe management of complex skull base lesions can be enhanced by intraoperative computed tomography (CT) scanning. Surgery in these areas requires real-time feedback of anatomic landmarks. Several portable CT scanners are currently available. We present a comparison of our clinical experience with three portable scanners in skull base and craniofacial surgery. We present clinical case series and the participants were from the Northwestern Memorial Hospital. Three scanners are studied: one conventional multidetector CT (MDCT), two digital flat panel cone-beam CT (CBCT) devices. Technical considerations, ease of use, image characteristics, and integration with image guidance are presented for each device. All three scanners provide good quality images. Intraoperative scanning can be used to update the image guidance system in real time. The conventional MDCT is unique in its ability to resolve soft tissue. The flat panel CBCT scanners generally emit lower levels of radiation and have less metal artifact effect. In this series, intraoperative CT scanning was technically feasible and deemed useful in surgical decision-making in 75% of patients. Intraoperative portable CT scanning has significant utility in complex skull base surgery. This technology informs the surgeon of the precise extent of dissection and updates intraoperative stereotactic navigation. PMID:22470270
Predicting hollow viscus injury in blunt abdominal trauma with computed tomography.
Bhagvan, Savitha; Turai, Matthew; Holden, Andrew; Ng, Alexander; Civil, Ian
2013-01-01
Evaluation of blunt abdominal trauma is controversial. Computed tomography (CT) of the abdomen is commonly used but has limitations, especially in excluding hollow viscus injury in the presence of solid organ injury. To determine whether CT reports alone could be used to direct operative treatment in abdominal trauma, this study was undertaken. The trauma database at Auckland City Hospital was accessed for patients who had abdominal CT and subsequent laparotomy during a five-year period. The CT scans were reevaluated by a consultant radiologist who was blinded to operative findings. The CT findings were correlated with the operative findings. Between January 2002 and December 2007, 1,250 patients were evaluated for blunt abdominal injury with CT. A subset of 78 patients underwent laparotomy, and this formed the study group. The sensitivity and specificity of CT scan in predicting hollow viscus injury was 55.33 and 92.06 % respectively. The positive and negative predictive values were 61.53 and 89.23 % respectively. Presence of free fluid in CT scan was sensitive in diagnosing hollow viscus injury (90 %). Specific findings for hollow viscus injuries on CT scan were free intraperitoneal air (93 %), retroperitoneal air (100 %), oral contrast extravasation (100 %), bowel wall defect (98 %), patchy bowel enhancement (97 %), and mesenteric abnormality (94 %). CT alone cannot be used as a screening tool for hollow viscus injury. The decision to operate in hollow viscus injury has to be based on mechanism of injury and clinical findings together with radiological evidence.
Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner
NASA Astrophysics Data System (ADS)
Grasruck, M.; Gupta, R.; Reichardt, B.; Suess, Ch.; Schmidt, B.; Stierstorfer, K.; Popescu, S.; Brady, T.; Flohr, T.
2006-03-01
We developed and evaluated a prototype flat-panel detector based Volume CT (fpVCT) scanner. The fpVCT scanner consists of a Varian 4030CB a-Si flat-panel detector mounted in a multi slice CT-gantry (Siemens Medical Solutions). It provides a 25 cm field of view with 18 cm z-coverage at the isocenter. In addition to the standard tomographic scanning, fpVCT allows two new scan modes: (1) fluoroscopic imaging from any arbitrary rotation angle, and (2) continuous, time-resolved tomographic scanning of a dynamically changing viewing volume. Fluoroscopic imaging is feasible by modifying the standard CT gantry so that the imaging chain can be oriented along any user-selected rotation angle. Scanning with a stationary gantry, after it has been oriented, is equivalent to a conventional fluoroscopic examination. This scan mode enables combined use of high-resolution tomography and real-time fluoroscopy with a clinically usable field of view in the z direction. The second scan mode allows continuous observation of a timeevolving process such as perfusion. The gantry can be continuously rotated for up to 80 sec, with the rotation time ranging from 3 to 20 sec, to gather projection images of a dynamic process. The projection data, that provides a temporal log of the viewing volume, is then converted into multiple image stacks that capture the temporal evolution of a dynamic process. Studies using phantoms, ex vivo specimens, and live animals have confirmed that these new scanning modes are clinically usable and offer a unique view of the anatomy and physiology that heretofore has not been feasible using static CT scanning. At the current level of image quality and temporal resolution, several clinical applications such a dynamic angiography, tumor enhancement pattern and vascularity studies, organ perfusion, and interventional applications are in reach.
Emergency medicine summary code for reporting CT scan results: implementation and survey results.
Lam, Joanne; Coughlin, Ryan; Buhl, Luce; Herbst, Meghan; Herbst, Timothy; Martillotti, Jared; Coughlin, Bret
2018-06-01
The purpose of the study was to assess the emergency department (ED) providers' interest and satisfaction with ED CT result reporting before and after the implementation of a standardized summary code for all CT scan reporting. A summary code was provided at the end of all CTs ordered through the ED from August to October of 2016. A retrospective review was completed on all studies performed during this period. A pre- and post-survey was given to both ED and radiology providers. A total of 3980 CT scans excluding CTAs were ordered with 2240 CTs dedicated to the head and neck, 1685 CTs dedicated to the torso, and 55 CTs dedicated to the extremities. Approximately 74% CT scans were contrast enhanced. Of the 3980 ED CT examination ordered, 69% had a summary code assigned to it. Fifteen percent of the coded CTs had a critical or diagnostic positive result. The introduction of an ED CT summary code did not show a definitive improvement in communication. However, the ED providers are in consensus that radiology reports are crucial their patients' management. There is slightly increased satisfaction with the providers with less than 5 years of experience with the ED CT codes compared to more seasoned providers. The implementation of a user-friendly summary code may allow better analysis of results, practice improvement, and quality measurements in the future.
Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun
2017-01-01
Background: Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Methods: Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images <60 keV in Group A. The total radiation dose, total iodine load, contrast injection speed, and maximum injection pressure were compared between the two groups. The 40 keV and 60 keV spectral CT images of Group A were compared with the images of Group B to evaluate overall image quality. Results: The total radiation dose, total iodine load, injection speed, and maximum injection pressure for Group A were decreased by 19%, 15%, 34.4%, and 18.3%, respectively. The optimal energy level in spectral CT for displaying the abdominal vessels was 40 keV. At this level, the CT values in the abdominal aorta and its three branches, the portal vein and its two branches, and the inferior vena cava were all greater than 340 hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and −1.716 for liver, −0.153 and −1.546 for pancreas, and 2.427 and 0.866 for renal cortex, all P > 0.05). Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t = −8.11 for liver, −7.83 for pancreas, and −5.38 for renal cortex, all P < 0.05). However, the subjective scores for the 40 keV (FBP) and 60 keV (40% ASiR) spectral CT images determined by two radiologists were all >3, indicating clinically acceptable image quality. Conclusions: Single-phase, dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality. PMID:28345547
Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun
2017-04-05
Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images <60 keV in Group A. The total radiation dose, total iodine load, contrast injection speed, and maximum injection pressure were compared between the two groups. The 40 keV and 60 keV spectral CT images of Group A were compared with the images of Group B to evaluate overall image quality. The total radiation dose, total iodine load, injection speed, and maximum injection pressure for Group A were decreased by 19%, 15%, 34.4%, and 18.3%, respectively. The optimal energy level in spectral CT for displaying the abdominal vessels was 40 keV. At this level, the CT values in the abdominal aorta and its three branches, the portal vein and its two branches, and the inferior vena cava were all greater than 340 hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and -1.716 for liver, -0.153 and -1.546 for pancreas, and 2.427 and 0.866 for renal cortex, all P> 0.05). Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t = -8.11 for liver, -7.83 for pancreas, and -5.38 for renal cortex, all P< 0.05). However, the subjective scores for the 40 keV (FBP) and 60 keV (40% ASiR) spectral CT images determined by two radiologists were all> 3, indicating clinically acceptable image quality. Single-phase, dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality.
Korporaal, Johannes G; Benz, Matthias R; Schindera, Sebastian T; Flohr, Thomas G; Schmidt, Bernhard
2016-01-01
The aim of this study was to introduce a new theoretical framework describing the relationship between the blood velocity, computed tomography (CT) acquisition velocity, and iodine contrast enhancement in CT images, and give a proof of principle of contrast gradient-based blood velocimetry with CT. The time-averaged blood velocity (v(blood)) inside an artery along the axis of rotation (z axis) is described as the mathematical division of a temporal (Hounsfield unit/second) and spatial (Hounsfield unit/centimeter) iodine contrast gradient. From this new theoretical framework, multiple strategies for calculating the time-averaged blood velocity from existing clinical CT scan protocols are derived, and contrast gradient-based blood velocimetry was introduced as a new method that can calculate v(blood) directly from contrast agent gradients and the changes therein. Exemplarily, the behavior of this new method was simulated for image acquisition with an adaptive 4-dimensional spiral mode consisting of repeated spiral acquisitions with alternating scan direction. In a dynamic flow phantom with flow velocities between 5.1 and 21.2 cm/s, the same acquisition mode was used to validate the simulations and give a proof of principle of contrast gradient-based blood velocimetry in a straight cylinder of 2.5 cm diameter, representing the aorta. In general, scanning with the direction of blood flow results in decreased and scanning against the flow in increased temporal contrast agent gradients. Velocity quantification becomes better for low blood and high acquisition speeds because the deviation of the measured contrast agent gradient from the temporal gradient will increase. In the dynamic flow phantom, a modulation of the enhancement curve, and thus alternation of the contrast agent gradients, can be observed for the adaptive 4-dimensional spiral mode and is in agreement with the simulations. The measured flow velocities in the downslopes of the enhancement curves were in good agreement with the expected values, although the accuracy and precision worsened with increasing flow velocities. The new theoretical framework increases the understanding of the relationship between the blood velocity, CT acquisition velocity, and iodine contrast enhancement in CT images, and it interconnects existing blood velocimetry methods with research on transluminary attenuation gradients. With these new insights, novel strategies for CT blood velocimetry, such as the contrast gradient-based method presented in this article, may be developed.
Winter, T C; Freeny, P C; Nghiem, H V; Mack, L A; Patten, R M; Thomas, C R; Elliott, S
1993-12-01
The purpose of this study was to evaluate the efficacy of superparmagnetic iron oxide (SPIO) in the detection of focal hepatic lesions on MR images. The study included 21 patients with 115 focal hepatic lesions and eight patients without focal hepatic lesions. T1- and T2-weighted MR images were obtained at 1.5 T before and 60 min after the end of injection of an SPIO agent. Contrast-enhanced CT scans were obtained in all patients within 10 days after MR imaging. The effect of SPIO on the signal intensity of the liver and spleen was assessed by using quantitative analysis of the region of interest. Efficacy was evaluated by using multiple criteria and unenhanced and SPIO-enhanced images. Evaluations included subjective assessment of image quality, counting the number of lesions detected, and statistical analysis of quantitative changes in the signal intensity of lesions and of normal liver. By all criteria, SPIO-enhanced T2-weighted MR images were superior to unenhanced T2-weighted images and to contrast-enhanced CT scans. Conversely, by all criteria, SPIO-enhanced T1-weighted MR images were worse than unenhanced T1-weighted images and contrast-enhanced CT scans. The mean lesion-to-liver contrast on T2-weighted images was 317% on unenhanced images and 1745% on SPIO-enhanced images. For T1-weighted, the mean contrast was 26% on unenhanced images and 18% on SPIO-enhanced images. SPIO is an efficacious contrast agent for the detection of focal hepatic lesions when T2-weighted MR images are used.
Jones, Jeryl C; Appt, Susan E; Werre, Stephen R; Tan, Joshua C; Kaplan, Jay R
2010-06-01
The purpose of this study was to validate low radiation dose, contrast-enhanced, multi-detector computed tomography (MDCT) as a non-invasive method for measuring ovarian volume in macaques. Computed tomography scans of four known-volume phantoms and nine mature female cynomolgus macaques were acquired using a previously described, low radiation dose scanning protocol, intravenous contrast enhancement, and a 32-slice MDCT scanner. Immediately following MDCT, ovaries were surgically removed and the ovarian weights were measured. The ovarian volumes were determined using water displacement. A veterinary radiologist who was unaware of actual volumes measured ovarian CT volumes three times, using a laptop computer, pen display tablet, hand-traced regions of interest, and free image analysis software. A statistician selected and performed all tests comparing the actual and CT data. Ovaries were successfully located in all MDCT scans. The iliac arteries and veins, uterus, fallopian tubes, cervix, ureters, urinary bladder, rectum, and colon were also consistently visualized. Large antral follicles were detected in six ovaries. Phantom mean CT volume was 0.702+/-SD 0.504 cc and the mean actual volume was 0.743+/-SD 0.526 cc. Ovary mean CT volume was 0.258+/-SD 0.159 cc and mean water displacement volume was 0.257+/-SD 0.145 cc. For phantoms, the mean coefficient of variation for CT volumes was 2.5%. For ovaries, the least squares mean coefficient of variation for CT volumes was 5.4%. The ovarian CT volume was significantly associated with actual ovarian volume (ICC coefficient 0.79, regression coefficient 0.5, P=0.0006) and the actual ovarian weight (ICC coefficient 0.62, regression coefficient 0.6, P=0.015). There was no association between the CT volume accuracy and mean ovarian CT density (degree of intravenous contrast enhancement), and there was no proportional or fixed bias in the CT volume measurements. Findings from this study indicate that MDCT is a valid non-invasive technique for measuring the ovarian volume in macaques.
Luo, Yaping; Wang, Ling; Pan, Qingqing; Ma, Yanru; Li, Fang
2018-07-01
A 51-year-old woman with a history of hypertension and abdominal pain was found with a retroperitoneal mass. The mass had intense enhancement in contrast-enhanced CT, and it showed a moderate degree of increased FDG uptake in PET/CT. The mass was also positive in somatostatin receptor scintigraphy with Tc-HYNIC-TOC, but it was negative in I-MIBG scan. The histopathological result after surgical resection of the mass confirmed the diagnosis of Castleman's disease, the hyaline vascular variant.
Hoegl, Sandra; Meinel, Felix G; Thieme, Sven F; Johnson, Thorsten R C; Eickelberg, Oliver; Zwissler, Bernhard; Nikolaou, Konstantin
2013-03-01
To evaluate the feasibility and incremental diagnostic value of xenon-enhanced dual-energy CT in mechanically ventilated intensive care patients with worsening respiratory function. The study was performed in 13 mechanically ventilated patients with severe pulmonary conditions (acute respiratory distress syndrome (ARDS), n=5; status post lung transplantation, n=5; other, n=3) and declining respiratory function. CT scans were performed using a dual-source CT scanner at an expiratory xenon concentration of 30%. Both ventilation images (Xe-DECT) and standard CT images were reconstructed from a single CT scan. Findings were recorded for Xe-DECT and standard CT images separately. Ventilation defects on xenon images were matched to morphological findings on standard CT images and incremental diagnostic information of xenon ventilation images was recorded if present. Mean xenon consumption was 2.95 l per patient. No adverse events occurred under xenon inhalation. In the visual CT analysis, the Xe-DECT ventilation defects matched with pathologic changes in lung parenchyma seen in the standard CT images in all patients. Xe-DECT provided additional diagnostic findings in 4/13 patients. These included preserved ventilation despite early pneumonia (n=1), more confident discrimination between a large bulla and pneumothorax (n=1), detection of an airway-to-pneumothorax fistula (n=1) and exclusion of a suspected airway-to-mediastinum fistula (n=1). In all 4 patients, the additional findings had a substantial impact on patients' management. Xenon-enhanced DECT is safely feasible and can add relevant diagnostic information in mechanically ventilated intensive care patients with worsening respiratory function. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Okada, Tadao; Sasaki, Fumiaki; Honda, Shouhei; Naitou, Satsuki; Onodera, Yuya; Todo, Satoru
2008-03-01
Magnetic resonance cholangiopancreatography (MRCP) is not sufficient to detect pancreaticobiliary maljunction (PBM) in young infants because the main pancreatic duct is not visualized and respiratory artifacts occur. To our knowledge, there are no reports highlighting the diagnostic accuracy of evaluation using the axial planes of helical computed tomographic (CT) scanning with contrast medium instead of 3-dimensional (3D) reconstruction. The aim of this study was to describe our experience and the characteristics of 3 children with PBM diagnosed using the axial planes of helical CT with contrast medium, although they showed negative findings of PBM by MRCP, instead of 3D reconstruction. Three patients aged from 1 month to 3 years were diagnosed with PBM using the axial planes of helical CT with contrast medium though MRCP could not show the common channel and/or the entrance of the common channel into the duodenum. In all 3 patients, PBM of the common channel was not revealed by MRCP. On the other hand, axial planes of contrast-enhanced helical CT scans showed PBM clearly. Our experience suggests that axial planes of the contrast-enhanced helical CT scan comprise an accurate tool for the diagnosis of fusiform-type PBM and could replace MRCP in younger children. Further studies are necessary for better assessment of the potential advantages and pitfalls of this modality.
NASA Astrophysics Data System (ADS)
Gong, Changfei; Han, Ce; Gan, Guanghui; Deng, Zhenxiang; Zhou, Yongqiang; Yi, Jinling; Zheng, Xiaomin; Xie, Congying; Jin, Xiance
2017-04-01
Dynamic myocardial perfusion CT (DMP-CT) imaging provides quantitative functional information for diagnosis and risk stratification of coronary artery disease by calculating myocardial perfusion hemodynamic parameter (MPHP) maps. However, the level of radiation delivered by dynamic sequential scan protocol can be potentially high. The purpose of this work is to develop a pre-contrast normal-dose scan induced structure tensor total variation regularization based on the penalized weighted least-squares (PWLS) criteria to improve the image quality of DMP-CT with a low-mAs CT acquisition. For simplicity, the present approach was termed as ‘PWLS-ndiSTV’. Specifically, the ndiSTV regularization takes into account the spatial-temporal structure information of DMP-CT data and further exploits the higher order derivatives of the objective images to enhance denoising performance. Subsequently, an effective optimization algorithm based on the split-Bregman approach was adopted to minimize the associative objective function. Evaluations with modified dynamic XCAT phantom and preclinical porcine datasets have demonstrated that the proposed PWLS-ndiSTV approach can achieve promising gains over other existing approaches in terms of noise-induced artifacts mitigation, edge details preservation, and accurate MPHP maps calculation.
Modelling of aortic aneurysm and aortic dissection through 3D printing.
Ho, Daniel; Squelch, Andrew; Sun, Zhonghua
2017-03-01
The aim of this study was to assess if the complex anatomy of aortic aneurysm and aortic dissection can be accurately reproduced from a contrast-enhanced computed tomography (CT) scan into a three-dimensional (3D) printed model. Contrast-enhanced cardiac CT scans from two patients were post-processed and produced as 3D printed thoracic aorta models of aortic aneurysm and aortic dissection. The transverse diameter was measured at five anatomical landmarks for both models, compared across three stages: the original contrast-enhanced CT images, the stereolithography (STL) format computerised model prepared for 3D printing and the contrast-enhanced CT of the 3D printed model. For the model with aortic dissection, measurements of the true and false lumen were taken and compared at two points on the descending aorta. Three-dimensional printed models were generated with strong and flexible plastic material with successful replication of anatomical details of aortic structures and pathologies. The mean difference in transverse vessel diameter between the contrast-enhanced CT images before and after 3D printing was 1.0 and 1.2 mm, for the first and second models respectively (standard deviation: 1.0 mm and 0.9 mm). Additionally, for the second model, the mean luminal diameter difference between the 3D printed model and CT images was 0.5 mm. Encouraging results were achieved with regards to reproducing 3D models depicting aortic aneurysm and aortic dissection. Variances in vessel diameter measurement outside a standard deviation of 1 mm tolerance indicate further work is required into the assessment and accuracy of 3D model reproduction. © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.
Klenk, Christopher; Gawande, Rakhee; Uslu, Lebriz; Khurana, Aman; Qiu, Deqiang; Quon, Andrew; Donig, Jessica; Rosenberg, Jarrett; Luna-Fineman, Sandra; Moseley, Michael; Daldrup-Link, Heike E
2014-03-01
Imaging tests are essential for staging of children with cancer. However, CT and radiotracer-based imaging procedures are associated with substantial exposure to ionising radiation and risk of secondary cancer development later in life. Our aim was to create a highly effective, clinically feasible, ionising radiation-free staging method based on whole-body diffusion-weighted MRI and the iron supplement ferumoxytol, used off-label as a contrast agent. We compared whole-body diffusion-weighted MRI with standard clinical (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT scans in children and young adults with malignant lymphomas and sarcomas. Whole-body diffusion-weighted magnetic resonance images were generated by coregistration of colour-encoded ferumoxytol-enhanced whole-body diffusion-weighted MRI scans for tumour detection with ferumoxytol-enhanced T1-weighted MRI scans for anatomical orientation, similar to the concept of integrated (18)F-FDG PET/CT scans. Tumour staging results were compared using Cohen's κ statistics. Histopathology and follow-up imaging served as the standard of reference. Data was assessed in the per-protocol population. This study is registered with ClinicalTrials.gov, number NCT01542879. 22 of 23 recruited patients were analysed because one patient discontinued before completion of the whole-body scan. Mean exposure to ionising radiation was 12·5 mSv (SD 4·1) for (18)F-FDG PET/CT compared with zero for whole-body diffusion-weighted MRI. (18)F-FDG PET/CT detected 163 of 174 malignant lesions at 1325 anatomical regions and whole-body diffusion-weighted MRI detected 158. Comparing (18)F-FDG PET/CT to whole-body diffusion-weighted MRI, sensitivities were 93·7% (95% CI 89·0-96·8) versus 90·8% (85·5-94·7); specificities 97·7% (95% CI 96·7-98·5) versus 99·5% (98·9-99·8); and diagnostic accuracies 97·2% (93·6-99·4) versus 98·3% (97·4-99·2). Tumour staging results showed very good agreement between both imaging modalities with a κ of 0·93 (0·81-1·00). No adverse events after administration of ferumoxytol were recorded. Ferumoxytol-enhanced whole-body diffusion-weighted MRI could be an alternative to (18)F-FDG PET/CT for staging of children and young adults with cancer that is free of ionising radiation. This new imaging test might help to prevent long-term side-effects from radiographic staging procedures. Thrasher Research Fund and Clinical Health Research Institute at Stanford University. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chen, Ying; Fu, Yan-Biao; Xu, Xiu-Fang; Pan, Yao; Lu, Chen-Ying; Zhu, Xiu-Liang; Li, Qing-Hai; Yu, Ri-Sheng
2018-01-01
The lymphadenitis associated with cat-scratch disease (CSD) is often confused with neoplasms by a number of radiologists and clinicians, and consequently, unnecessary invasive procedures or surgeries are performed. In the present study, the contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) findings of 10 patients (6 men and 4 women) with clinically and pathologically confirmed lymphadenitis associated with CSD were retrospectively analyzed (CT in 3 patients, MRI in 6 patients, and CT and MRI in 1 patient) at The Second Affiliated Hospital of Zhejiang University School of Medicine (Hangzhou, China) between January 2007 and November 2014. As a result, 17 enlarged lymph nodes were identified in 10 cases. The 5 nodes identified by CT scan exhibited relatively inhomogeneous isodensity to muscle, with patchy low density in the center. All 14 nodes identified by MRI scan exhibited homogeneous or heterogeneous isointensity to muscle or slightly increased intensity compared with that of muscle on T1-weighted images (T1WI), and homogeneous or heterogeneous hyperintensity on fat-suppressed T2WI. Following enhancement, all 17 enlarged lymph nodes associated with CSD demonstrated the following 3 different enhancement patterns: Moderate homogeneous enhancement (n=8), which was associated with histologically identified early disease stage; marked heterogeneous enhancement with no enhancement of the necrotic areas (n=4), and heterogeneous enhancement with progressively 'spoke-wheel-like' (defined as radiating enhancement from the center) enhancement of the patchy low-density area (n=1), which was associated with histologically identified intermediate disease stage; and astral low-density/hypointensity with marked enhancement (n=2) or a 'rose flower' sign (n=2), which was associated with histologically identified late disease stage. We hypothesized that the CT and MRI results of lymphadenitis in CSD may be associated with the pathological features. It may be suggested that the diagnosis of CSD may be formed when considering the characteristic CT and MRI features of astral low-density/hypointensity with marked enhancement or a 'rose flower' sign (defined as marginal petaloid enhancement) in the late disease stage, or the MRI results of homogeneous, moderate enhancement in the early disease stage, or the CT/MRI data of heterogeneous enhancement with non-enhancing area in the center in the intermediate disease stage, in solitary or multiple enlarged lymph nodes associated with general subcutaneous edema in the vicinity of the nodes on CT/MRI and with a history of cat exposure.
Bulla, A; Casoli, C; Farace, F; Mazzarello, V; De Luca, L; Rubino, C; Montella, A
2014-01-01
The aim of the present study is to propose a new contrast agent that can be easily applied both to CT and dissection studies to replace lead oxide based formulas for comparative anatomical analyses of the vascularisation of cadaveric specimens. The infusion material was an epoxy resin, especially modified by the addition of barium sulphate to enhance its radiopacity. The final copolymer was toxicologically safe. To test the properties of the new material, several cadaveric limb injections were performed. The injected specimens were both CT scanned to perform 3D vascular reconstructions and dissected by anatomical planes. There was a perfect correspondence between the image studies and the dissections: even the smallest arteries on CT scan can be identified on the specimen and vice versa. The properties of the epoxy allowed an easy dissection of the vessels. The new imaging techniques available today, such as CT scan, can evaluate the vascular anatomy in high detail and 3D. This new contrast agent may help realising detailed vascular studies comparing CT scan results with anatomical dissections. Moreover, it may be useful for teaching surgical skills in the field of plastic surgery.
Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai Weixing; Zhao Binghui; Conover, David
2012-01-15
Purpose: This research is designed to develop and evaluate a flat-panel detector-based dynamic cone beam CT system for dynamic angiography imaging, which is able to provide both dynamic functional information and dynamic anatomic information from one multirevolution cone beam CT scan. Methods: A dynamic cone beam CT scan acquired projections over four revolutions within a time window of 40 s after contrast agent injection through a femoral vein to cover the entire wash-in and wash-out phases. A dynamic cone beam CT reconstruction algorithm was utilized and a novel recovery method was developed to correct the time-enhancement curve of contrast flow.more » From the same data set, both projection-based subtraction and reconstruction-based subtraction approaches were utilized and compared to remove the background tissues and visualize the 3D vascular structure to provide the dynamic anatomic information. Results: Through computer simulations, the new recovery algorithm for dynamic time-enhancement curves was optimized and showed excellent accuracy to recover the actual contrast flow. Canine model experiments also indicated that the recovered time-enhancement curves from dynamic cone beam CT imaging agreed well with that of an IV-digital subtraction angiography (DSA) study. The dynamic vascular structures reconstructed using both projection-based subtraction and reconstruction-based subtraction were almost identical as the differences between them were comparable to the background noise level. At the enhancement peak, all the major carotid and cerebral arteries and the Circle of Willis could be clearly observed. Conclusions: The proposed dynamic cone beam CT approach can accurately recover the actual contrast flow, and dynamic anatomic imaging can be obtained with high isotropic 3D resolution. This approach is promising for diagnosis and treatment planning of vascular diseases and strokes.« less
Re-modelled CT unit quickly up to speed.
2011-06-01
Medical turnkey pre-installation specialist Canute International Medical Services (CIMS) recently supported provider of managed equipment services Asteral in a project to re-model the Rowan Bentall wing of Surrey's Kingston Hospital. The new CT scanning facility was developed by Asteral via an MES agreement, elements of which included two new CT scanners, major refurbishment of the existing building, and ongoing maintenance and finance. As HEJ editor Jonathan Baillie reports, despite a tight two-month schedule, the project team's expertise, and meticulous co-ordination and planning, enabled the delivery of a significantly enhanced facility on time and on budget with minimal disruption and without a single day's scanning being lost.
Subacute sclerosing panencephalitis. Changes on CT scan during acute relapse.
Modi, G; Campbell, H; Bill, P
1989-01-01
A 19-year-old female patient presented in an acute state of akinetic mutism. Serological analysis of serum and cerebrospinal fluid demonstrated the presence of antibodies to measles virus. CT scan carried out during this acute phase of relapse demonstrated white matter enhancement affecting the cortical white matter of the frontal lobes and corpus callosum. These features indicate that active demyelination occurs during acute relapse in subacute sclerosing panencephalitis (SSPE) and suggest that immunotherapy should be considered during this acute phase.
Dynamic contrast enhanced CT in nodule characterization: How we review and report.
Qureshi, Nagmi R; Shah, Andrew; Eaton, Rosemary J; Miles, Ken; Gilbert, Fiona J
2016-07-18
Incidental indeterminate solitary pulmonary nodules (SPN) that measure less than 3 cm in size are an increasingly common finding on computed tomography (CT) worldwide. Once identified there are a number of imaging strategies that can be performed to help with nodule characterization. These include interval CT, dynamic contrast enhanced computed tomography (DCE-CT), (18)F-fluorodeoxyglucose positron emission tomography-computed tomography ((18)F-FDG-PET-CT). To date the most cost effective and efficient non-invasive test or combination of tests for optimal nodule characterization has yet to be determined.DCE-CT is a functional test that involves the acquisition of a dynamic series of images of a nodule before and following the administration of intravenous iodinated contrast medium. This article provides an overview of the current indications and limitations of DCE- CT in nodule characterization and a systematic approach to how to perform, analyse and interpret a DCE-CT scan.
Han, Dong; Ma, Guangming; Wei, Lequn; Ren, Chenglong; Zhou, Jieli; Shen, Chen
2017-01-01
Objective: To investigate the value of using the quantitative parameters from only the pre-contrast dual-energy spectral CT imaging for distinguishing between parapelvic cyst and hydronephrosis with non-calculous (HNC). Methods: This retrospective study was approved by the institutional review board. 28 patients with parapelvic cyst and 24 patients with HNC who underwent standard pre-contrast and multiphase contrast-enhanced dual-energy spectral CT imaging were retrospectively identified. The parapelvic cyst and HNC were identified using the contrast-enhanced scans, and their CT number in the 70-keV monochromatic images, effective atomic number (Zeff), iodine concentration (IC) and water concentration in the pre-contrast images were measured. The slope of the spectral curve (λ) was calculated. The difference in the measurements between parapelvic cyst and HNC was statistically analyzed using SPSS® v. 19.0 (IBM Corp., New York, NY; formerly SPSS Inc., Chicago, IL) statistical software. Receiver-operating characteristic analysis was performed to assess the diagnostic performance. Results: The CT numbers in the 70-keV images, Zeff and IC values were statistically different between parapelvic cyst and HNC (all p < 0.05). The sensitivity, specificity and accuracy of these parameters for distinguishing between parapelvic cyst and HNC were 89.2%, 73.3% and 82.1%; 86.5%, 43.3% and 67.2%; 91.9%, 40.0% and 68.7%; and 64.9%, 73.3% and 83.6%, respectively, and the combined specificity was 92.9%. There was no statistical difference in λ between the two groups (p > 0.05). Conclusion: The quantitative parameters obtained in the pre-contrast dual-energy spectral CT imaging may be used to differentiate between parapelvic cyst and HNC. Advances in knowledge: The pre-contrast dual-energy spectral CT scans may be used to screen parapelvic cysts for patients who are asymptomatic, thereby avoiding contrast-enhanced CT or CT urography examination for these patients to reduce ionizing radiation dose and contrast dose. PMID:28281789
Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... conditions: Birth (congenital) defect of the head or brain Brain infection Brain tumor Buildup of fluid inside ...
Diagnosis of non-occlusive acute mesenteric ischemia in the intensive care unit.
Bourcier, Simon; Oudjit, Ammar; Goudard, Geoffrey; Charpentier, Julien; Leblanc, Sarah; Coriat, Romain; Gouya, Hervé; Dousset, Bertrand; Mira, Jean-Paul; Pène, Frédéric
2016-12-01
Non-occlusive mesenteric ischemia (NOMI) is a common complication and accounts for a major cause of death in critically ill patients. The diagnosis of NOMI with respect to the eventual indications for surgical treatment is challenging. We addressed the performance of the diagnostic strategy of NOMI in the intensive care unit, with emphasis on contrast-enhanced abdominal CT-scan. This was a retrospective monocenter study. Patients with clinically suspected acute mesenteric ischemia were included if a comprehensive diagnostic workup was carried out including surgical and/or endoscopic digestive explorations. Patients with evidence of occlusive mesenteric ischemia were excluded. A definite diagnosis of NOMI only relied on surgical or endoscopic findings. Abdominal CT-scans were reviewed by two radiologists blinded from the final diagnosis. A diagnosis of NOMI could be definitely confirmed or ruled out through surgical or endoscopic explorations of the digestive tract in 147 patients. With respect to their clinical characteristics, only a history of atrial fibrillation was an independent predictor of NOMI (odds ratio 8.3, 95% confidence interval 2.0-35.2, p = 0.004). Among them, 114 patients (75 with and 39 without NOMI) had previously been subjected to contrast-enhanced abdominal CT-scan. Portal venous gas, pneumatosis intestinalis and, to a lesser extent, abnormal contrast-induced bowel wall enhancement were poorly sensitive, but exhibited good specificities of 95, 85 and 71%, respectively. Nineteen out of 75 patients (25.3%) without any suggestive radiological signs finally exhibited mesenteric ischemia, including ten with intestinal necrosis. The performance of abdominal CT-scan for the diagnosis of NOMI is limited. Radiological signs of advanced-stage ischemia are good predictors of definite mesenteric ischemia, while their absence should not be considered sufficient to rule out the diagnosis.
Strauch, Louise S; Eriksen, Rie Ø; Sandgaard, Michael; Kristensen, Thomas S; Nielsen, Michael B; Lauridsen, Carsten A
2016-07-21
The aim of this study was to provide an overview of the literature available on dynamic contrast-enhanced computed tomography (DCE-CT) as a tool to evaluate treatment response in patients with lung cancer. This systematic review was compiled according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Only original research articles concerning treatment response in patients with lung cancer assessed with DCE-CT were included. To assess the validity of each study we implemented Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). The initial search yielded 651 publications, and 16 articles were included in this study. The articles were divided into groups of treatment. In studies where patients were treated with systemic chemotherapy with or without anti-angiogenic drugs, four out of the seven studies found a significant decrease in permeability after treatment. Four out of five studies that measured blood flow post anti-angiogenic treatments found that blood flow was significantly decreased. DCE-CT may be a useful tool in assessing treatment response in patients with lung cancer. It seems that particularly permeability and blood flow are important perfusion values for predicting treatment outcome. However, the heterogeneity in scan protocols, scan parameters, and time between scans makes it difficult to compare the included studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leng, S; Vrieze, T; Kuhlmann, J
2014-06-15
Purpose: To assess image quality and radiation dose reduction in abdominal CT imaging, physical phantoms having realistic background textures and lesions are highly desirable. The purpose of this work was to construct a liver phantom with realistic background and lesions using patient CT images and a 3D printer. Methods: Patient CT images containing liver lesions were segmented into liver tissue, contrast-enhanced vessels, and liver lesions using commercial software (Mimics, Materialise, Belgium). Stereolithography (STL) files of each segmented object were created and imported to a 3D printer (Object350 Connex, Stratasys, MN). After test scans were performed to map the eight availablemore » printing materials into CT numbers, printing materials were assigned to each object and a physical liver phantom printed. The printed phantom was scanned on a clinical CT scanner and resulting images were compared with the original patient CT images. Results: The eight available materials used to print the liver phantom had CT number ranging from 62 to 117 HU. In scans of the liver phantom, the liver lesions and veins represented in the STL files were all visible. Although the absolute value of the CT number in the background liver material (approx. 85 HU) was higher than in patients (approx. 40 HU), the difference in CT numbers between lesions and background were representative of the low contrast values needed for optimization tasks. Future work will investigate materials with contrast sufficient to emulate contrast-enhanced arteries. Conclusion: Realistic liver phantoms can be constructed from patient CT images using a commercial 3D printer. This technique may provide phantoms able to determine the effect of radiation dose reduction and noise reduction techniques on the ability to detect subtle liver lesions in the context of realistic background textures.« less
Pourmand, Ali; Woodward, Christina; Shokoohi, Hamid; King, Jordan B; Taheri, M Reza; King, Jackson; Lawrence, Christopher
2018-01-01
Context Web-based learning (WBL) modules are effectively used to improve medical education curriculum; however, they have not been evaluated to improve head computed tomography (CT) scan interpretation in an emergency medicine (EM) setting. Objective To evaluate the effectiveness of a WBL module to aid identification of cranial structures on CT and to improve ability to distinguish between normal and abnormal findings. Design Prospective, before-and-after trial in the Emergency Department of an academic center. Baseline head CT knowledge was assessed via a standardized test containing ten head CT scans, including normal scans and those showing hemorrhagic stroke, trauma, and infection (abscess). All trainees then participated in a WBL intervention. Three weeks later, they were given the same ten CT scans to evaluate in a standardized posttest. Main Outcome Measures Improvement in test scores. Results A total of 131 EM clerkship students and 32 EM residents were enrolled. Pretest scores correlated with stage of training, with students and first-year residents demonstrating the lowest scores. Overall, there was a significant improvement in percentage of correctly classified CT images after the training intervention from a mean pretest score of 32% ± 12% to posttest score of 67% ± 13% (mean improvement = 35% ± 13%, p < 0.001). Among subsets by training level, all subgroups except first-year residents demonstrated a statistically significant increase in scores after the training. Conclusion Incorporating asynchronous WBL modules into EM clerkship and residency curriculum provides early radiographic exposure in their clinical training and can enhance diagnostic head CT scan interpretation. PMID:29272248
Knoedler, Margaret; Feibus, Allison H; Lange, Andrew; Maddox, Michael M; Ledet, Elisa; Thomas, Raju; Silberstein, Jonathan L
2015-06-01
To evaluate the effect of 3-dimensionally (3D) printed physical renal models with enhancing masses on medical trainee characterization, localization, and understanding of renal malignancy. Proprietary software was used to import standard computed tomography (CT) cross-sectional imaging into 3D printers to create physical models of renal units with enhancing renal lesions in situ. Six different models were printed from a transparent plastic resin; the normal parenchyma was printed in a clear, translucent plastic, with a red hue delineating the suspicious renal lesion. Medical students, who had completed their first year of training, were given an overview and tasked with completion of RENAL nephrometry scores, separately using CT imaging and 3D models. Trainees were also asked to complete a questionnaire about their experience. Variability between trainees was assessed by intraclass correlation coefficients (ICCs), and kappa statistics were used to compare the trainee to experts. Overall trainee nephrometry score accuracy was significantly improved with the 3D model vs CT scan (P <.01). Furthermore, 3 of the 4 components of the nephrometry score (radius, nearness to collecting system, and location) showed significant improvement (P <.001) using the models. There was also more consistent agreement among trainees when using the 3D models compared with CT scans to assess the nephrometry score (intraclass correlation coefficient, 0.28 for CT scan vs 0.72 for 3D models). Qualitative evaluation with questionnaires filled out by the trainees further confirmed that the 3D models improved their ability to understand and conceptualize the renal mass. Physical 3D models using readily available printing techniques improve trainees' understanding and characterization of individual patients' enhancing renal lesions. Published by Elsevier Inc.
Park, Ji Eun; Choi, Young Hun; Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One; Cho, Hyun Suk; Ryu, Young Jin; Kim, Yu Jin
2017-05-01
Computed tomography (CT) has generated public concern associated with radiation exposure, especially for children. Lowering the tube voltage is one strategy to reduce radiation dose. To assess the image quality and radiation dose of non-enhanced brain CT scans acquired at 80 kilo-voltage peak (kVp) compared to those at 120 kVp in children. Thirty children who had undergone both 80- and 120-kVp non-enhanced brain CT were enrolled. For quantitative analysis, the mean attenuation of white and gray matter, attenuation difference, noise, signal-to-noise ratio, contrast-to-noise ratio and posterior fossa artifact index were measured. For qualitative analysis, noise, gray-white matter differentiation, artifact and overall image quality were scored. Radiation doses were evaluated by CT dose index, dose-length product and effective dose. The mean attenuations of gray and white matter and contrast-to-noise ratio were significantly increased at 80 kVp, while parameters related to image noise, i.e. noise, signal-to-noise ratio and posterior fossa artifact index were higher at 80 kVp than at 120 kVp. In qualitative analysis, 80-kVp images showed improved gray-white differentiation but more artifacts compared to 120-kVp images. Subjective image noise and overall image quality scores were similar between the two scans. Radiation dose parameters were significantly lower at 80 kVp than at 120 kVp. In pediatric non-enhanced brain CT scans, a decrease in tube voltage from 120 kVp to 80 kVp resulted in improved gray-white matter contrast, comparable image quality and decreased radiation dose.
Bae, Kyungsoo; Jeon, Kyung N; Park, Mi J; Lee, Seung J; Kim, Ho C; Cha, Seung I; Byun, Joung H; Kim, Jong W
2017-07-01
Infected paratracheal air cysts as the focus of respiratory symptoms can be overlooked in practice because of nonspecific symptoms and physician's scant knowledge for this entity. We report 2 cases of infected paratracheal air cyst diagnosed at chest computed tomography (CT) and bronchoscopy/endobronchial ultrasound. Two patients visited our hospital with respiratory symptoms, including cough, sputum, and fever. Chest CT showed paratracheal cystic lesions with air-fluid level in the thoracic inlet. In the first patient, endobronchial ultrasound revealed a right paratracheal hypoechoic mass corresponding to the lesion on CT scan. In the second patient, bronchoscopy revealed purulent discharge from a dimpling at posterolateral wall of trachea, which was the opening of communication between the trachea and infected paratracheal air cyst. Both patients received antibiotic treatment. After medical treatment, the patients' symptoms were improved. Follow-up chest CT scans showed air-filled paratracheal air cysts without internal fluid or rim enhancement. A physician should pay attention to paratracheal air cyst in patients with respiratory symptoms when their lungs are clear on CT scan.
Agarwal, Saurabh; Jokerst, Clinton; Siegel, Marilyn J; Hildebolt, Charles
2015-08-01
This article compares the technical factors-in particular, tube current and voltage-and the resultant exposure to radiation associated with CT examinations performed at a children's hospital and at more general community hospital emergency departments (EDs). CT scans obtained at community hospital EDs were retrospectively reviewed and compared with CT scans obtained at a children's hospital, to assess differences in kilovoltage, tube current, and volume CT dose index (CTDIvol) used. The number of scans obtained during the contrast-enhanced phase was also assessed. Parametric and nonparametric statistical analyses were used to test differences. A total of 233 body CT examinations were performed at community hospitals, and 287 were performed at a children's hospital. At both types of hospital, the median patient age was 12 years (p = 0.66). Of the body CT scans obtained at community hospitals that focused on the care of adult patients, 194 of 233 (83%) used a tube voltage of 120 kVp, 29 of 233 (12%) used 100 kVp, and two of 233 (< 1%) used 80 kVp. Of the body CT scans obtained at the children's hospital, 121 of 287 (42%) used a tube voltage of 120 kVp, 129 of 287 (45%) used 100 kVp, and 36 of 287 (13%) used 80 kVp. The median tube current was also lower at the children's hospital (110 vs 125 mA) (p < 0.001). At the community hospitals, 11 of 233 studies were multiphasic, whereas at the children's hospital, there were no multiphasic studies. For all CT types, the median CTDIvol was 4.9 mGy (range, 2.5-8.2 mGy) at the children's hospital and 8.6 mGy (range, 6.0-14.4 mGy) at the community hospitals (p < 0.001). The results of this study suggest that a large proportion of children who undergo CT at community hospitals receive relatively higher radiation doses than children who undergo CT at children's hospitals. This finding is related to the higher tube settings (in particular, kilovoltage) used at community hospitals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, T; Boone, J; Kent, M
Purpose: Pulmonary perfusion imaging has provided significant insights into pulmonary diseases, and can be useful in radiotherapy. The purpose of this study was to prospectively establish proof-of-principle in a canine model for single-energy CT-based perfusion imaging, which has the potential for widespread clinical implementation. Methods: Single-energy CT perfusion imaging is based on: (1) acquisition of inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast medium, (2) deformable image registration (DIR) of the two CT image data sets, and (3) subtraction of the pre-contrast image from post-contrast image, yielding a map of Hounsfield unit (HU) enhancement. These subtractionmore » image data sets hypothetically represent perfused blood volume, a surrogate for perfusion. In an IACUC-approved clinical trial, we acquired pre- and post-contrast CT scans in the prone posture for six anesthetized, mechanically-ventilated dogs. The elastix algorithm was used for DIR. The registration accuracy was quantified using the target registration errors (TREs) for 50 pulmonary landmarks in each dog. The gradient of HU enhancement between gravity-dependent (ventral) and non-dependent (dorsal) regions was evaluated to quantify the known effect of gravity, i.e., greater perfusion in ventral regions. Results: The lung volume difference between the two scans was 4.3±3.5% on average (range 0.3%–10.1%). DIR demonstrated an average TRE of 0.7±1.0 mm. HU enhancement in lung parenchyma was 34±10 HU on average and varied considerably between individual dogs, indicating the need for improvement of the contrast injection protocol. HU enhancement in ventral (gravity-dependent) regions was found to be greater than in dorsal regions. A population average ventral-to-dorsal gradient of HU enhancement was strong (R{sup 2}=0.94) and statistically significant (p<0.01). Conclusion: This canine study demonstrated relatively accurate DIR and a strong ventral-to-dorsal gradient of HU enhancement, providing proof-of-principle for single-energy CT pulmonary perfusion imaging. This ongoing study will enroll more dogs and investigate the physiological significance. This study was supported by a Philips Healthcare/Radiological Society of North America (RSNA) Research Seed Grant (RSD1458)« less
[Suprasellar arachnoid cyst--report of a case (author's transl)].
Takahashi, T; Kawai, S; Kaminoh, T; Hiramatsu, K; Maekawa, M; Yuasa, T; Miyamoto, N; Hattori, Y
1982-04-01
A 4-year-old boy with suprasellar arachnoid cyst was reported. At the age of 30-month-old his aunt was aware of his squint. During the observation by ophthalmologists from the age of 1y. to 3y., enlargement of the head and impairment of the visual acuity were manifested. Cranial CT scan revealed the enlargement of the ventricular system and a round low density area located superior to the sella. Absorption coefficient of the lesion was similar to that of the cerebrospinal fluid. No abnormal contrast enhancement was seen. Examination revealed the head circumference of 53.3 cm larger than doubled standard deviation, the right external strabismus, impaired vision (R:0.03, L:0.3) and optic atrophy but no other neurological signs. Cerebral angiography showed suprasellar mass lesion. After the ventriculography with water-soluble contrast medium, V-P shunt operation was performed and then the patient was transferred to the CT room. CSF enhanced CT scan showed no communication between the ventricles and the cyst. By frontotemporal approach, microsurgical removal of the cystwall was performed and the histological diagnosis was arachnoid membrane. Several days after the operation, bilateral subdural effusion was seen on CT scan and was treated with bilateral S-P shunt and the removal of V-P shunt. Follow up CT scan disclosed the disappearance of the subdural effusion and the suprasellar cyst. The visual acuity was improved well and the endocrinological study was normal. Analysis of the 45 reported cases of suprasellar arachnoid cyst suggested that direct removal of the cyst wall is better than the V-P shunt operation and the cyst shunting is advisable for repeat recurrence of the cyst. Removal of the ventricular shunting system may be effective for the prevention of the subdural effusion as a complication after direct operation.
Linguraru, Marius George; Pura, John A; Chowdhury, Ananda S; Summers, Ronald M
2010-01-01
The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis (CAD) applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D erosion using population historic information of contrast-enhanced liver, spleen, and kidneys was applied to multi-phase data to initialize the 4D graph and adapt to patient specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance and enhancement, and shape and location on organ segmentation.
Bertolo, Riccardo; Fiori, Cristian; Piramide, Federico; Amparore, Daniele; Barrera, Monica; Sardo, Diego; Veltri, Andrea; Porpiglia, Francesco
2018-05-14
To evaluate the correlation between the loss of renal function as assessed by Tc99MAG-3 renal scan and the loss of renal volume as calculated by volumetric assessment on CT-scan in patients who underwent minimally-invasive partial nephrectomy (PN). PN prospectively-maintained database was retrospectively queried for patients who underwent minimally-invasive PN (2012-2017) for renal mass
Triple-phase helical computed tomography in dogs with solid splenic masses
KUTARA, Kenji; SEKI, Mamiko; ISHIGAKI, Kumiko; TESHIMA, Kenji; ISHIKAWA, Chieko; KAGAWA, Yumiko; EDAMURA, Kazuya; NAKAYAMA, Tomohiro; ASANO, Kazushi
2017-01-01
We investigated the utility of triple-phase helical computed tomography (CT) in differentiating between benign and malignant splenic masses in dogs. Forty-two dogs with primary splenic masses underwent triple-phase helical CT scanning (before administration of contrast, and in the arterial phase, portal venous phase, and delayed phase) prior to splenectomy. Tissue specimens were sent for pathological diagnosis; these included hematomas (n=14), nodular hyperplasias (n=12), hemangiosarcomas (n=11), and undifferentiated sarcomas (n=5). The CT findings were compared with the histological findings. Nodular hyperplasia significantly displayed a homogeneous normal enhancement pattern in all phases. Hemangiosarcoma displayed 2 significant contrast-enhancement patterns, including a homogeneous pattern of poor enhancement in all phases, and a heterogeneous remarkable enhancement pattern in the arterial and portal venous phases. Hematoma and undifferentiated sarcoma displayed a heterogeneous normal enhancement pattern in all phases. The contrast-enhanced volumetric ratios of hematoma tended to be greater than those of undifferentiated sarcoma. Our study demonstrated that the characteristic findings on triple-phase helical CT could be useful for the preoperative differentiation of hematoma, nodular hyperplasia, hemangiosarcoma, and undifferentiated sarcoma in dogs. Triple-phase helical CT may be a useful diagnostic tool in dogs with splenic masses. PMID:28993600
Role of multidetector computed tomography in evaluating incidentally detected breast lesions.
Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile
2015-01-01
Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.
Saukko, Annina E A; Honkanen, Juuso T J; Xu, Wujun; Väänänen, Sami P; Jurvelin, Jukka S; Lehto, Vesa-Pekka; Töyräs, Juha
2017-12-01
Cartilage injuries may be detected using contrast-enhanced computed tomography (CECT) by observing variations in distribution of anionic contrast agent within cartilage. Currently, clinical CECT enables detection of injuries and related post-traumatic degeneration based on two subsequent CT scans. The first scan allows segmentation of articular surfaces and lesions while the latter scan allows evaluation of tissue properties. Segmentation of articular surfaces from the latter scan is difficult since the contrast agent diffusion diminishes the image contrast at surfaces. We hypothesize that this can be overcome by mixing anionic contrast agent (ioxaglate) with bismuth oxide nanoparticles (BINPs) too large to diffuse into cartilage, inducing a high contrast at the surfaces. Here, a dual contrast method employing this mixture is evaluated by determining the depth-wise X-ray attenuation profiles in intact, enzymatically degraded, and mechanically injured osteochondral samples (n = 3 × 10) using a microCT immediately and at 45 min after immersion in contrast agent. BiNPs were unable to diffuse into cartilage, producing high contrast at articular surfaces. Ioxaglate enabled the detection of enzymatic and mechanical degeneration. In conclusion, the dual contrast method allowed detection of injuries and degeneration simultaneously with accurate cartilage segmentation using a single scan conducted at 45 min after contrast agent administration.
Solitary pulmonary nodule: A rare presentation of pulmonary mucormycosis in an immunocompetent adult
Sarkar, Supriya; Jash, Debraj; Maji, Arnab; Maikap, Malay Kr
2014-01-01
Pulmonary mucormycosis is a rare opportunistic infection of immunocompromised individuals. Here, we report a case of 70-year-old male, smoker presenting with high-grade fever for 2 weeks and episodes of hemoptysis. Contrast-enhanced computed tomography (CT) thorax revealed a solitary pulmonary nodule measuring 2.3 × 1.6 cm in the right upper lobe. CT guided fine needle aspiration cytology and true cut biopsy showed plenty of typical fungal hyphae consistent with the diagnosis of mucormycosis. Fungal culture confirmed the organism as mucor. Positron emission tomography-CT scan showed a non- 18 fluorodeoxy glucose avid nodule ruling out possibility of malignancy. Investigation did not reveal any evidence of immunosuppression. Patient was treated with intravenous liposomal amphotericin B for 4 weeks. Follow-up chest X-ray and CT scan after 6 weeks were normal. PMID:24669089
Farolfi, Alberto; Carretta, Elisa; Luna, Corradina Della; Ragazzini, Angela; Gentili, Nicola; Casadei, Carla; Barone, Domenico; Minguzzi, Martina; Amadori, Dino; Nanni, Oriana; Gavelli, Giampaolo
2014-10-31
Cancer patients undergo routine computed-tomography (CT) scans and, therefore, iodinated contrast media (ICM) administration. It is not known whether a time-dependent correlation exists between chemotherapy administration, contrast enhanced CT and onset of acute ICM-related adverse reactions (ARs). All consecutive contrast-enhanced CTs performed from 1 January 2010 to 31 December 2012 within 30 days of the last chemotherapy administration were retrospectively reviewed. Episodes of acute ICM-related ARs were reported to the pharmacovigilance officer. We analyzed time to CT evaluation calculated as the time elapsed from the date of the CT performed to the date of the last chemotherapy administration. Patients were classified into 4 groups based on the antineoplastic treatment: platinum-based, taxane-based, platinum plus taxane and other group. Out of 10,472 contrast-enhanced CTs performed, 3,945 carried out on 1,878 patients were considered for the study. Forty acute ICM-related ARs (1.01%; 95% CI, 0.70-1.33) were reported. No differences were seen among immediate (within 10 days of the last chemotherapy administration), early (11-20 days) and delayed (21-30 days) CTs. Median time to CT in patients who experienced an acute ICM-related AR by treatment group was not statistically different: 20 days (range 6-30), 17 days (range 5-22), 13 days (range 8-17), 13 days (range (2-29) for the platinum, taxane, platinum plus taxane and other group, respectively (P =0.251). Our results did not reveal any correlation between time to CT and risk of acute ICM-related ARs in cancer patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noid, G; Chen, G; Tai, A
2014-06-01
Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. For CT in radiation therapy (RT), slightly increasing imaging dose to improve IQ may be justified if it can substantially enhance structure delineation. The purpose of this study is to investigate and to quantify the IQ enhancement as a result of increasing imaging doses and using IR algorithms. Methods: CT images were acquired for phantoms, built to evaluate IQ metrics including spatial resolution, contrast and noise, with a variety of imaging protocols using a CT scanner (Definition ASmore » Open, Siemens) installed inside a Linac room. Representative patients were scanned once the protocols were optimized. Both phantom and patient scans were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and the Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared. Results: IR techniques are demonstrated to preserve spatial resolution as measured by the point spread function and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is doubled by adopting the highest SAFIRE strength. As expected, increasing imaging dose reduces noise for both SAFIRE and FBP reconstructions. The contrast to noise increases from 3 to 5 by increasing the dose by a factor of 4. Similar IQ improvement was observed on the CTs for selected patients with pancreas and prostrate cancers. Conclusion: The IR techniques produce a measurable enhancement to CT IQ by reducing the noise. Increasing imaging dose further reduces noise independent of the IR techniques. The improved CT enables more accurate delineation of tumors and/or organs at risk during RT planning and delivery guidance.« less
CAT scan - pelvis; Computed axial tomography scan - pelvis; Computed tomography scan - pelvis; CT scan - pelvis ... Risks of CT scans include: Being exposed to radiation Allergic reaction to contrast dye CT scans do expose you to more radiation ...
CAT scan - shoulder; Computed axial tomography scan - shoulder; Computed tomography scan - shoulder; CT scan - shoulder ... Risks of CT scans include: Being exposed to radiation Allergic reaction to contrast dye Birth defect if done during pregnancy CT scans ...
CAT scan - sinus; Computed axial tomography scan - sinus; Computed tomography scan - sinus; CT scan - sinus ... Risks for a CT scan includes: Being exposed to radiation Allergic reaction to contrast dye CT scans expose you to more radiation than regular ...
Toepker, Michael; Moritz, Thomas; Krauss, Bernhard; Weber, Michael; Euller, Gordon; Mang, Thomas; Wolf, Florian; Herold, Christian J; Ringl, Helmut
2012-03-01
To evaluate the reliability of attenuation values in virtual non-contrast images (VNC) reconstructed from contrast-enhanced, dual-energy scans performed on a second-generation dual-energy CT scanner, compared to single-energy, non-contrast images (TNC). Sixteen phantoms containing a mixture of contrast agent and water at different attenuations (0-1400 HU) were investigated on a Definition Flash-CT scanner using a single-energy scan at 120 kV and a DE-CT protocol (100 kV/SN140 kV). For clinical assessment, 86 patients who received a dual-phase CT, containing an unenhanced single-energy scan at 120 kV and a contrast enhanced (110 ml Iomeron 400 mg/ml; 4 ml/s) DE-CT (100 kV/SN140 kV) in an arterial (n=43) or a venous phase, were retrospectively analyzed. Mean attenuation was measured within regions of interest of the phantoms and in different tissue types of the patients within the corresponding VNC and TNC images. Paired t-tests and Pearson correlation were used for statistical analysis. For all phantoms, mean attenuation in VNC was 5.3±18.4 HU, with respect to water. In 86 patients overall, 2637 regions were measured in TNC and VNC images, with a mean difference between TNC and VNC of -3.6±8.3 HU. In 91.5% (n=2412) of all cases, absolute differences between TNC and VNC were under 15HU, and, in 75.3% (n=1986), differences were under 10 HU. Second-generation dual-energy CT based VNC images provide attenuation values close to those of TNC. To avoid possible outliers multiple measurements are recommended especially for measurements in the spleen, the mesenteric fat, and the aorta. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Kazmierczak, Philipp M; Rominger, Axel; Wenter, Vera; Spitzweg, Christine; Auernhammer, Christoph; Angele, Martin K; Rist, Carsten; Cyran, Clemens C
2017-04-01
To quantify the additional value of 68 Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced 68 Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and 68 Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up 68 Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p < 0.001). 68 Ga-DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. • 68 Ga-DOTA-TATE PET augments the sensitivity of contrast-enhanced CT by 50 % • 68 Ga-DOTA-TATE PET augments the accuracy of contrast-enhanced CT by 30 % • Somatostatin receptor-targeted hybrid imaging optimizes primary tumour detection in CUP-NET.
Colonic metastasis from breast carcinoma: a case report.
Tsujimura, Kazuma; Teruya, Tsuyoshi; Kiyuna, Masaya; Higa, Kuniki; Higa, Junko; Iha, Kouji; Chinen, Kiyoshi; Asato, Masaya; Takushi, Yasukatsu; Ota, Morihito; Dakeshita, Eijirou; Nakachi, Atsushi; Gakiya, Akira; Shiroma, Hiroshi
2017-07-05
Colonic metastasis from breast carcinoma is very rare. Here, we report a case of colonic metastasis from breast carcinoma. The patient was a 51-year-old woman. She had upper abdominal pain, vomiting, and diarrhea, repeatedly. We performed abdominal contrast-enhanced computed tomography (CT) to investigate these symptoms. The CT scan revealed a tumor in the ascending colon with contrast enhancement and showed an expanded small intestine. For further investigation of this tumor, we performed whole positron emission tomography-computed tomography (PET-CT). The PET-CT scan revealed fluorodeoxyglucose uptake in the ascending colon, mesentery, left breast, and left axillary region. Analysis of biopsy samples obtained during colonoscopy revealed signet ring cell-like carcinoma. Moreover, biopsy of the breast tumor revealed invasive lobular carcinoma. Therefore, the preoperative diagnosis was colonic metastasis from breast carcinoma. Open ileocecal resection was performed. The final diagnosis was multiple metastatic breast carcinomas, and the TNM classification was T2N1M1 Stage IV. We presented a rare case of colonic metastasis from breast carcinoma. PET-CT may be useful in the diagnosis of metastatic breast cancer. When analysis of biopsy samples obtained during colonoscopy reveals signet ring cell-like carcinoma, the possibility of breast cancer as the primary tumor should be considered.
Image processing based detection of lung cancer on CT scan images
NASA Astrophysics Data System (ADS)
Abdillah, Bariqi; Bustamam, Alhadi; Sarwinda, Devvi
2017-10-01
In this paper, we implement and analyze the image processing method for detection of lung cancer. Image processing techniques are widely used in several medical problems for picture enhancement in the detection phase to support the early medical treatment. In this research we proposed a detection method of lung cancer based on image segmentation. Image segmentation is one of intermediate level in image processing. Marker control watershed and region growing approach are used to segment of CT scan image. Detection phases are followed by image enhancement using Gabor filter, image segmentation, and features extraction. From the experimental results, we found the effectiveness of our approach. The results show that the best approach for main features detection is watershed with masking method which has high accuracy and robust.
Su, Yin-Ping; Niu, Hao-Wei; Chen, Jun-Bo; Fu, Ying-Hua; Xiao, Guo-Bing; Sun, Quan-Fu
2014-03-07
To quantify the radiation dose in the thyroid attributable to different CT scans and to estimate the thyroid cancer risk in pediatric patients. The information about pediatric patients who underwent CT scans was abstracted from the radiology information system in one general hospital between 1 January 2012 and 31 December 2012. The radiation doses were calculated using the ImPACT Patient Dosimetry Calculator and the lifetime attributable risk (LAR) of thyroid cancer incidence was estimated based on the National Academies Biologic Effects of Ionizing Radiation VII model. The subjects comprised 922 children, 68% were males, and received 971 CT scans. The range of typical radiation dose to the thyroid was estimated to be 0.61-0.92 mGy for paranasal sinus CT scans, 1.10-2.45 mGy for head CT scans, and 2.63-5.76 mGy for chest CT scans. The LAR of thyroid cancer were as follows: for head CT, 1.1 per 100,000 for boys and 8.7 per 100,000 for girls; for paranasal sinus CT scans, 0.4 per 100,000 for boys and 2.7 per 100,000 for girls; for chest CT scans, 2.2 per 100,000 for boys and 14.2 per 100,000 for girls. The risk of thyroid cancer was substantially higher for girls than for the boys, and from chest CT scans was higher than that from head or paransal sinus CT scans. Chest CT scans caused higher thyroid dose and the LAR of thyroid cancer incidence, compared with paransal sinus or head CT scans. Therefore, physicians should pay more attention to protect the thyroid when children underwent CT scans, especially chest CT scans.
Joo, Yeon Hee; Kim, Jin Pyeong; Park, Jung Je
2014-01-01
Objectives The goal of this study was to define the radiologic characteristics of two-phase computed tomography (CT) of salivary gland Warthin tumors and to compare them to pleomorphic adenomas. We also aimed to provide a foundation for selecting a surgical method on the basis of radiologic findings. Methods We prospectively enrolled 116 patients with parotid gland tumors, who underwent two-phase CT preoperatively. Early and delayed phase scans were obtained, with scanning delays of 30 and 120 seconds, respectively. The attenuation changes and enhancement patterns were analyzed. In cases when the attenuation changes were decreased, we presumed Warthin tumor preoperatively and performed extracapsular dissection. When the attenuation changes were increased, superficial parotidectomy was performed on the parotid gland tumors. We analyzed the operation times, incision sizes, complications, and recurrence rates. Results Attenuation of Warthin tumors was decreased from early to delayed scans. The ratio of CT numbers in Warthin tumors was also significantly different from other tumors. Warthin tumors were diagnosed with a sensitivity of 96.1% and specificity of 97% using two-phase CT. The mean operation time was 38 minutes and the mean incision size was 36.2 mm for Warthin tumors. However, for the other parotid tumors, the average operation time was 122 minutes and the average incision size was 91.8 mm (P<0.05). Conclusion Salivary Warthin tumor has a distinct pattern of contrast enhancement on two-phase CT, which can guide treatment decisions. The preoperative diagnosis of Warthin tumor made extracapsular dissection possible instead of superficial parotidectomy. PMID:25177439
Joo, Yeon Hee; Kim, Jin Pyeong; Park, Jung Je; Woo, Seung Hoon
2014-09-01
The goal of this study was to define the radiologic characteristics of two-phase computed tomography (CT) of salivary gland Warthin tumors and to compare them to pleomorphic adenomas. We also aimed to provide a foundation for selecting a surgical method on the basis of radiologic findings. We prospectively enrolled 116 patients with parotid gland tumors, who underwent two-phase CT preoperatively. Early and delayed phase scans were obtained, with scanning delays of 30 and 120 seconds, respectively. The attenuation changes and enhancement patterns were analyzed. In cases when the attenuation changes were decreased, we presumed Warthin tumor preoperatively and performed extracapsular dissection. When the attenuation changes were increased, superficial parotidectomy was performed on the parotid gland tumors. We analyzed the operation times, incision sizes, complications, and recurrence rates. Attenuation of Warthin tumors was decreased from early to delayed scans. The ratio of CT numbers in Warthin tumors was also significantly different from other tumors. Warthin tumors were diagnosed with a sensitivity of 96.1% and specificity of 97% using two-phase CT. The mean operation time was 38 minutes and the mean incision size was 36.2 mm for Warthin tumors. However, for the other parotid tumors, the average operation time was 122 minutes and the average incision size was 91.8 mm (P<0.05). Salivary Warthin tumor has a distinct pattern of contrast enhancement on two-phase CT, which can guide treatment decisions. The preoperative diagnosis of Warthin tumor made extracapsular dissection possible instead of superficial parotidectomy.
CT vs. MRCP in choledocholithiasis jaundice.
Petrescu, I; Bratu, A M; Petrescu, S; Popa, B V; Cristian, D; Burcos, T
2015-01-01
Obstructive jaundice can raise problems to diagnostic imaging. The radiologist must choose the most appropriate examination that delivers the most important diagnostic information because the differences between a lithiasic obstruction and a tumoral one are vital. This information helps the surgeon speed up the process of decision-making, because the treatment may be very different in relation to the nature of the obstruction. This study tries to demonstrate the diagnostic accuracy of computed tomography (CT) and magnetic resonance cholangiopancreatography (MRCP) in detecting the obstacle in the common bile duct (CBD) and the possibility of establishing the lithiasic nature of the obstruction. A retrospective analysis was analyzed during an interval of 18 months that included jaundice patients admitted in the General Surgery Department of "Coltea" Clinical Hospital. They were examined by CT scanning and by MRCP, being suspected of choledocholithiasis. 63 patients were included in the study, 34 females and 29 males. 33 CT scans and 30 MRCP exams were performed. CT scan is useful in detecting residual or iterative choledocholithiasis in patients after cholecystectomy, contrast enhanced CT (CECT), being able to differentiate between lithiasic and non-lithiasic obstruction. MRCP delivers important anatomic details of the biliary tree; it is superior to CT in diagnosing the hepatocholedochal lithiasis; MRCP tends to replace endoscopic retrograde cholangiopancreatography (ERCP)--the diagnostic "gold standard" reducing the number of unnecessary invasive diagnostic procedures.
Congenital bronchopulmonary malformation: CT histopathological correlation.
Kyncl, Martin; Koci, Martin; Ptackova, Lea; Hornofova, Ludmila; Ondrej, Fabian; Snajdauf, Jiri; Pychova, Marcela
2016-12-01
This study evaluated the accuracy of postnatal computed tomography (CT) imaging in the identification of congenital bronchopulmonary malformation (BPM) in comparison with histopathological analysis. CT scans of prenatally diagnosed BPMs from 24 patients with available histology were analysed retrospectively. The CT images were reviewed blinded to histological findings by two radiologists. Specific diagnosis was assigned based on predetermined criteria. The accuracy of CT was evaluated. The agreement rate in CT diagnosis between two radiologists was 100%. In 75% the lesions were located in the lower lobes. An overlap of 71% in CT and histopathological diagnoses was reached. The least matching diagnosis was type 2 CPAM. Contrast enhanced chest CT is very accurate in characterizing the BPM spectrum and provides important information on lesion type and structure.
Energy-discriminating X-ray computed tomography system utilizing a cadmium telluride detector
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Abderyim, Purkhet; Enomoto, Toshiyuki; Watanabe, Manabu; Hitomi, Keitaro; Takahasi, Kiyomi; Sato, Shigehiro; Ogawae, Akira; Onagawa, Jun
2010-07-01
An energy-discriminating K-edge X-ray computed tomography (CT) system is useful for increasing contrast resolution of a target region utilizing contrast media and for reducing the absorbed dose for patients. The CT system is of the first-generation type with a cadmium telluride (CdTe) detector, and a projection curve is obtained by translation scanning using the CdTe detector in conjunction with an x-stage. An object is rotated by the rotation step angle using a turntable between the translation scans. Thus, CT is carried out by repeating the translation scanning and the rotation of an object. Penetrating X-ray photons from the object are detected by the CdTe detector, and event signals of X-ray photons are produced using charge-sensitive and shaping amplifiers. Both the photon energy and the energy width are selected by use of a multi-channel analyzer, and the number of photons is counted by a counter card. Demonstration of enhanced iodine K-edge X-ray CT was carried out by selecting photons with energies just beyond the iodine K-edge energy of 33.2 keV.
NASA Astrophysics Data System (ADS)
Yusob, Diana; Zukhi, Jihan; Aziz Tajuddin, Abd; Zainon, Rafidah
2017-05-01
The aim of this study was to evaluate the efficacy of metal artefact reduction using contrasts media in Computed Tomography (CT) imaging. A water-based abdomen phantom of diameter 32 cm (adult body size) was fabricated using polymethyl methacrylate (PMMA) material. Three different contrast agents (iodine, barium and gadolinium) were filled in small PMMA tubes and placed inside a water-based PMMA adult abdomen phantom. The orthopedic metal screw was placed in each small PMMA tube separately. These two types of orthopedic metal screw (stainless steel and titanium alloy) were scanned separately. The orthopedic metal crews were scanned with single-energy CT at 120 kV and dual-energy CT at fast kV-switching between 80 kV and 140 kV. The scan modes were set automatically using the current modulation care4Dose setting and the scans were set at different pitch and slice thickness. The use of the contrast media technique on orthopedic metal screws were optimised by using pitch = 0.60 mm, and slice thickness = 5.0 mm. The use contrast media can reduce the metal streaking artefacts on CT image, enhance the CT images surrounding the implants, and it has potential use in improving diagnostic performance in patients with severe metallic artefacts. These results are valuable for imaging protocol optimisation in clinical applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xue, M; Patel, K; Regine, W
2014-06-01
Purpose: To study the feasibility of individually optimized contrastenhancement (CE) 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. To evaluate the image quality and contrast enhancement of tumor in the CE 4D-CT, compared to the clinical standard of CE 3D-CT and 4D-CT. Methods: In this IRB-approved study, each of the 7 PDA patients enrolled underwent 3 CT scans: a free-breathing 3D-CT with contrast (CE 3D-CT) followed by a 4D-CT without contrast (4D-CT) in the first study session, and a 4D-CT with individually synchronized contrast injection (CE 4D-CT) in the second study session. In CE 4D-CT, the time of full contrastmore » injection was determined based on the time of peak enhancement for the test injection, injection rate, table speed, and longitudinal location and span of the pancreatic region. Physicians contoured both the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (end-of-exhalation for 4D-CT). The contrast between the tumor and normal pancreatic tissue was computed as the difference of the mean enhancement level of three 1 cm3 regions of interests in T and P, respectively. Wilcoxon rank sum test was used to statistically compare the scores and contrasts. Results: In qualitative evaluations, both CE 3D-CT and CE 4D-CT scored significantly better than 4D-CT (4.0 and 3.6 vs. 2.6). There was no significant difference between CE 3D-CT and CE 4D-CT. In quantitative evaluations, the contrasts between the tumor and the normal pancreatic parenchyma were 0.6±23.4, −2.1±8.0, and −19.6±28.8 HU, in CE 3D-CT, 4D-CT, and CE 4D-CT, respectively. Although not statistically significant, CE 4D-CT achieved better contrast enhancement between the tumor and the normal pancreatic parenchyma than both CE 3D-CT and 4DCT. Conclusion: CE 4D-CT achieved equivalent image quality and better contrast enhancement between tumor and normal pancreatic parenchyma than the clinical standard of CE 3D-CT and 4D-CT. This study was supported in part by Philips Healthcare.« less
Xu, Lingyu; Xu, Yuancheng; Coulden, Richard; Sonnex, Emer; Hrybouski, Stanislau; Paterson, Ian; Butler, Craig
2018-05-11
Epicardial adipose tissue (EAT) volume derived from contrast enhanced (CE) computed tomography (CT) scans is not well validated. We aim to establish a reliable threshold to accurately quantify EAT volume from CE datasets. We analyzed EAT volume on paired non-contrast (NC) and CE datasets from 25 patients to derive appropriate Hounsfield (HU) cutpoints to equalize two EAT volume estimates. The gold standard threshold (-190HU, -30HU) was used to assess EAT volume on NC datasets. For CE datasets, EAT volumes were estimated using three previously reported thresholds: (-190HU, -30HU), (-190HU, -15HU), (-175HU, -15HU) and were analyzed by a semi-automated 3D Fat analysis software. Subsequently, we applied a threshold correction to (-190HU, -30HU) based on mean differences in radiodensity between NC and CE images (ΔEATrd = CE radiodensity - NC radiodensity). We then validated our findings on EAT threshold in 21 additional patients with paired CT datasets. EAT volume from CE datasets using previously published thresholds consistently underestimated EAT volume from NC dataset standard by a magnitude of 8.2%-19.1%. Using our corrected threshold (-190HU, -3HU) in CE datasets yielded statistically identical EAT volume to NC EAT volume in the validation cohort (186.1 ± 80.3 vs. 185.5 ± 80.1 cm 3 , Δ = 0.6 cm 3 , 0.3%, p = 0.374). Estimating EAT volume from contrast enhanced CT scans using a corrected threshold of -190HU, -3HU provided excellent agreement with EAT volume from non-contrast CT scans using a standard threshold of -190HU, -30HU. Copyright © 2018. Published by Elsevier B.V.
Focal nodular hyperplasia coexistent with hepatoblastoma in a 36-d-old infant
Gong, Ying; Chen, Lian; Qiao, Zhong-Wei; Ma, Yang-Yang
2015-01-01
Focal nodular hyperplasia (FNH) is a benign hepatic tumor characterized by hepatocyte hyperplasia and a central stellate scar. The association of FNH with other hepatic lesions, such as adenomas, hemangiomas and hepatocellular carcinoma, has been previously reported, but FNH associated with another hepatic tumor is rare in infants. Here we report a case of FNH coexistent with hepatoblastoma in a 36-d-old girl. Computed tomography (CT) imaging showed an ill-delineated, inhomogeneous enhanced mass with a central star-like scar in the right lobe of the liver. The tumor showed early mild enhancement at the arterial phase (from 40HU without contrast to 52HU at the arterial phase), intense enhancement at the portal phase (87.7HU) and 98.1HU in the 3-min delay scan. A central scar in the tumor presented as low density on non-contrast CT and slightly enhanced at delayed contrast-enhanced scanning. This infant underwent surgical resection of the tumor. Histopathology demonstrated typical FNH coexistent with a focal hepatoblastoma, which showed epithelioid tumor cells separated by proliferated fibrous tissue. PMID:25624742
Focal nodular hyperplasia coexistent with hepatoblastoma in a 36-d-old infant.
Gong, Ying; Chen, Lian; Qiao, Zhong-Wei; Ma, Yang-Yang
2015-01-21
Focal nodular hyperplasia (FNH) is a benign hepatic tumor characterized by hepatocyte hyperplasia and a central stellate scar. The association of FNH with other hepatic lesions, such as adenomas, hemangiomas and hepatocellular carcinoma, has been previously reported, but FNH associated with another hepatic tumor is rare in infants. Here we report a case of FNH coexistent with hepatoblastoma in a 36-d-old girl. Computed tomography (CT) imaging showed an ill-delineated, inhomogeneous enhanced mass with a central star-like scar in the right lobe of the liver. The tumor showed early mild enhancement at the arterial phase (from 40HU without contrast to 52HU at the arterial phase), intense enhancement at the portal phase (87.7HU) and 98.1HU in the 3-min delay scan. A central scar in the tumor presented as low density on non-contrast CT and slightly enhanced at delayed contrast-enhanced scanning. This infant underwent surgical resection of the tumor. Histopathology demonstrated typical FNH coexistent with a focal hepatoblastoma, which showed epithelioid tumor cells separated by proliferated fibrous tissue.
Nellensteijn, David R; Greuter, Marcel J; El Moumni, Moustafa; Hulscher, Jan B
2016-08-01
We set out to determine the diagnostic value of computed tomographic (CT) scans in relation to the radiation dose, tumor incidence, and tumor mortality by radiation for hemodynamically stable pediatric patients with blunt abdominal injury. We focused on the changes in management because of new information obtained by CT. CT scans for suspected pediatric abdominal injury performed in our accident and emergency department were retrieved from the radiology registry and analyzed for: injury and hemodynamic parameters, changes in therapy, and radiological interventions. The dose length product (DLP) was used to calculate the effective dose (ED) and with the BEIR VII report we calculated the estimated induced lifetime tumor and mortality risk. Seventy-two patients underwent abdominal CT scanning for suspicion of abdominal injury and eight patients were excluded for hemodynamic instability, leaving 64 hemodynamically stable patients. Four patients died (6%). On the remaining 60 patients, only one laparotomy was performed for suspicion of duodenal perforation. Only in three out of the 64 hemodynamically stable cases (5%), a CT scan brought forward an indication for intervention or change in management. One patient was suspected of a duodenal perforation and underwent a laparotomy. A grade II hepatic laceration, but no duodenal, injury was found. Two patients underwent embolization of the splenic artery. One for an arterial blush caused by splenic laceration as was observed on the contrast enhanced-CT. Patient remained stable and during the angiogram the blush had disappeared. The second patient underwent (prophylactic) selective arterial embolization for having sustained a grade V splenic injury. The median radiation dosage was 11.43 mSv (range 1.19-23.76 mSv) in our patients. The use of the BEIR VII methodology results in an estimated increase in the lifetime tumor incidence of 0.17% (range, 0.05-0.67%) and an estimated increase in lifetime tumor incidence of 0.08% (0.02-0.28%). The results of our data suggest that the use of CT scans can largely be avoided in hemodynamically stable children with blunt abdominal injury. Georg Thieme Verlag KG Stuttgart · New York.
Jain, Avani S.; Shelley, Simon; Muthukrishnan, Indirani; Kalal, Shilpa; Amalachandran, Jaykanth; Chandran, Sureshkumar
2016-01-01
Aims and Objectives: To assess the diagnostic utility of contrast-enhanced 18F-fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET-ceCT) in localization of tumors in patients with clinical diagnosis of tumor-induced osteomalacia (TIO), in correlation with histopathological results. Materials and Methods: Eight patients (five male and three female) aged 24–60 (mean 42) years with a clinical diagnosis of TIO were included in this prospective study. They underwent whole body (head to toe) FDG PET-ceCT following a standard protocol on Philips GEMINI TF PET-CT scanner. The FDG PET-ceCT results were correlated with postoperative histology findings and clinical follow-up. Results: All the patients had an abnormal PET-ceCT study. The sensitivity of PET-ceCT was 87.5%, and positive predictive value was 100%. The tumor was located in the craniofacial region in 6/8 patients and in bone in 2/8 patients. Hemangiopericytoma was the most common reported histology. All patients underwent surgery, following which they demonstrated clinical improvement. However, one patient with atypical findings on histology did not show any clinical improvement, hence, underwent 68Gallium-DOTANOC PET-ceCT scan for relocalization of the site of the tumor. Conclusion: The tumors causing TIO are small in size and usually located in obscure sites in the body. Hence, head to toe protocol should be followed for FDG PET-ceCT scans with the inclusion of upper limbs. Once the tumor is localized, regional magnetic resonance imaging can be performed for better characterization of soft tissue lesion. Imaging with FDG PET-ceCT plays an important role in detecting the site of the tumor and thereby facilitating timely management. PMID:26917888
Jain, Avani S; Shelley, Simon; Muthukrishnan, Indirani; Kalal, Shilpa; Amalachandran, Jaykanth; Chandran, Sureshkumar
2016-01-01
To assess the diagnostic utility of contrast-enhanced (18)F-fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET-ceCT) in localization of tumors in patients with clinical diagnosis of tumor-induced osteomalacia (TIO), in correlation with histopathological results. Eight patients (five male and three female) aged 24-60 (mean 42) years with a clinical diagnosis of TIO were included in this prospective study. They underwent whole body (head to toe) FDG PET-ceCT following a standard protocol on Philips GEMINI TF PET-CT scanner. The FDG PET-ceCT results were correlated with postoperative histology findings and clinical follow-up. All the patients had an abnormal PET-ceCT study. The sensitivity of PET-ceCT was 87.5%, and positive predictive value was 100%. The tumor was located in the craniofacial region in 6/8 patients and in bone in 2/8 patients. Hemangiopericytoma was the most common reported histology. All patients underwent surgery, following which they demonstrated clinical improvement. However, one patient with atypical findings on histology did not show any clinical improvement, hence, underwent (68)Gallium-DOTANOC PET-ceCT scan for relocalization of the site of the tumor. The tumors causing TIO are small in size and usually located in obscure sites in the body. Hence, head to toe protocol should be followed for FDG PET-ceCT scans with the inclusion of upper limbs. Once the tumor is localized, regional magnetic resonance imaging can be performed for better characterization of soft tissue lesion. Imaging with FDG PET-ceCT plays an important role in detecting the site of the tumor and thereby facilitating timely management.
Su, Yin-Ping; Niu, Hao-Wei; Chen, Jun-Bo; Fu, Ying-Hua; Xiao, Guo-Bing; Sun, Quan-Fu
2014-01-01
Objective: To quantify the radiation dose in the thyroid attributable to different CT scans and to estimate the thyroid cancer risk in pediatric patients. Methods: The information about pediatric patients who underwent CT scans was abstracted from the radiology information system in one general hospital between 1 January 2012 and 31 December 2012. The radiation doses were calculated using the ImPACT Patient Dosimetry Calculator and the lifetime attributable risk (LAR) of thyroid cancer incidence was estimated based on the National Academies Biologic Effects of Ionizing Radiation VII model. Results: The subjects comprised 922 children, 68% were males, and received 971 CT scans. The range of typical radiation dose to the thyroid was estimated to be 0.61–0.92 mGy for paranasal sinus CT scans, 1.10–2.45 mGy for head CT scans, and 2.63–5.76 mGy for chest CT scans. The LAR of thyroid cancer were as follows: for head CT, 1.1 per 100,000 for boys and 8.7 per 100,000 for girls; for paranasal sinus CT scans, 0.4 per 100,000 for boys and 2.7 per 100,000 for girls; for chest CT scans, 2.1 per 100,000 for boys and 14.1 per 100,000 for girls. The risk of thyroid cancer was substantially higher for girls than for the boys, and from chest CT scans was higher than that from head or paransal sinus CT scans. Conclusions: Chest CT scans caused higher thyroid dose and the LAR of thyroid cancer incidence, compared with paransal sinus or head CT scans. Therefore, physicians should pay more attention to protect the thyroid when children underwent CT scans, especially chest CT scans. PMID:24608902
Perisinakis, Kostas; Seimenis, Ioannis; Tzedakis, Antonis; Pagonidis, Kostas; Papadakis, Antonios E; Damilakis, John
2013-10-15
This study provides data on the cumulative life attributable risk (LAR) of radiation-induced cancer from the combination of coronary CT angiography (CCTA), dynamic CT perfusion (CTP) and delayed enhancement (DE) CT scans, required for reliable risk-benefit analysis of the one-stop-shop CCTA + CTP + DECT cardiac examination. Monte Carlo simulation of the dynamic CTP and DECT exposures on 62 adult individuals was employed to determine radiation absorbed dose to exposed radiosensitive organs. Corresponding data for CCTA were derived using patient chest circumference and previously published data. Individual-specific LARs of cancer were estimated using organ/tissue-specific radiogenic cancer risk factors. Total LAR from CCTA + CTP + DECT scans' sequence were estimated and compared to nominal intrinsic risk of cancer. The main contribution, up to 80%, to cumulative radiation burden from CCTA + CTP + DECT scan-sequence was found to originate from the CTP scan. The total LAR from CCTA + CTP + DECT for females was found 4-6 times higher, compared to males. The mean cumulative risk of radiogenic cancer associated with the complete CCTA + CTP + DECT scan sequence was found to marginally increase the intrinsic risk for cancer induction by less than 0.6% and 0.1% for females and males, respectively. The radiation risk from the 256-slice CCTA + CTP + DECT scan sequence may be considered low and should not constitute an obstacle for the clinical endorsement of the one-stop-shop cardiac CT examination, given that its clinical value has been well verified. Nevertheless, every effort should be made towards optimization of the dynamic CTP component which is the main contributor to patient radiation burden. © 2013.
Rennert, J; Georgieva, M; Schreyer, A G; Jung, W; Ross, C; Stroszczynski, C; Jung, E M
2011-01-01
To evaluate, whether image fusion of contrast enhanced ultrasound (CEUS) with CT or MRI affects the diagnosis and characterization of liver lesions or the therapeutic strategy of surgical or interventional procedures compared to the preliminary diagnosis. In a retrospective study the image fusion scans of CEUS with contrast enhanced CT or MRI of 100 patients (71 male, mean age 59 years, 0.3-85 years) with benign or malignant liver lesions were evaluated. Fundamental B-scan, color Doppler imaging and CEUS were performed in all patients by an experienced examiner using a multifrequency convex transducer (1-5 MHz, LOGIQ 9/GE) and volume navigation (Vnav). After a bolus injections of up to 2.4 ml SonoVue® (BRACCO, Italy) digital raw data was stored as cine-loops up to 5 min. In 74 patients, CEUS was fused with a pre-existing ceCT, in 26 patients a ceMRI was used. In all 100 patients (100%) the image quality in all modalities (ceCT, ceMRI and CEUS) was excellent or with only minor diagnostic limitations. Regarding the number of lesions revealed in image fusion of CEUS/ceCT/ceMRI and the preceding diagnostic method, concordant results were found in 84 patients. In 12 patients, additional lesions were found using fusion imaging causing subsequently a change of the therapeutical strategy. In 15 out of 21 patients with either concordant or discordant results regarding the number of lesions, image fusion allowed a definite diagnosis due to a continuous documentation of the microcirculation of the tumor and its contrast enhancement. A significant coherency (p < 0.05) among image fusion with either ceCT or ceMRI and CEUS and a subsequent change of therapeutic strategy was found. Image fusion with volume navigation (VNav) of CEUS with ceCT or ceMRI frequently allows a definite localization and diagnosis of hepatic lesions in patients with primary hepatic carcinoma or metastatic diseases. This might cause a change of the therapeutic strategy in many patients with hepatic lesions.
Rahaghi, Farbod N; Vegas-Sanchez-Ferrero, Gonzalo; Minhas, Jasleen K; Come, Carolyn E; De La Bruere, Isaac; Wells, James M; González, Germán; Bhatt, Surya P; Fenster, Brett E; Diaz, Alejandro A; Kohli, Puja; Ross, James C; Lynch, David A; Dransfield, Mark T; Bowler, Russel P; Ledesma-Carbayo, Maria J; San José Estépar, Raúl; Washko, George R
2017-05-01
Imaging-based assessment of cardiovascular structure and function provides clinically relevant information in smokers. Non-cardiac-gated thoracic computed tomographic (CT) scanning is increasingly leveraged for clinical care and lung cancer screening. We sought to determine if more comprehensive measures of ventricular geometry could be obtained from CT using an atlas-based surface model of the heart. Subcohorts of 24 subjects with cardiac magnetic resonance imaging (MRI) and 262 subjects with echocardiography were identified from COPDGene, a longitudinal observational study of smokers. A surface model of the heart was manually initialized, and then automatically optimized to fit the epicardium for each CT. Estimates of right and left ventricular (RV and LV) volume and free-wall curvature were then calculated and compared to structural and functional metrics obtained from MRI and echocardiograms. CT measures of RV dimension and curvature correlated with similar measures obtained using MRI. RV and LV volume obtained from CT inversely correlated with echocardiogram-based estimates of RV systolic pressure using tricuspid regurgitation jet velocity and LV ejection fraction respectively. Patients with evidence of RV or LV dysfunction on echocardiogram had larger RV and LV dimensions on CT. Logistic regression models based on demographics and ventricular measures from CT had an area under the curve of >0.7 for the prediction of elevated right ventricular systolic pressure and ventricular failure. These data suggest that non-cardiac-gated, non-contrast-enhanced thoracic CT scanning may provide insight into cardiac structure and function in smokers. Copyright © 2017. Published by Elsevier Inc.
Xue, Ming; Lane, Barton F.; Kang, Min Kyu; Patel, Kruti; Regine, William F.; Klahr, Paul; Wang, Jiahui; Chen, Shifeng; D’Souza, Warren; Lu, Wei
2016-01-01
Purpose: To develop an individually optimized contrast-enhanced (CE) 4D-computed tomography (CT) for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). Methods: Ten PDA patients were enrolled. Each underwent three CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT using test injection. Three physicians contoured the tumor and pancreatic tissues. Image quality scores, tumor volume, motion, tumor-to-pancreas contrast, and contrast-to-noise ratio (CNR) were compared in the three CTs. Interobserver variations were also evaluated in contouring the tumor using simultaneous truth and performance level estimation. Results: Average image quality scores for CE 3D-CT and CE 4D-CT were comparable (4.0 and 3.8, respectively; P = 0.082), and both were significantly better than that for 4D-CT (2.6, P < 0.001). Tumor-to-pancreas contrast results were comparable in CE 3D-CT and CE 4D-CT (15.5 and 16.7 Hounsfield units (HU), respectively; P = 0.21), and the latter was significantly higher than in 4D-CT (9.2 HU, P = 0.001). Image noise in CE 3D-CT (12.5 HU) was significantly lower than in CE 4D-CT (22.1 HU, P = 0.013) and 4D-CT (19.4 HU, P = 0.009). CNRs were comparable in CE 3D-CT and CE 4D-CT (1.4 and 0.8, respectively; P = 0.42), and both were significantly better in 4D-CT (0.6, P = 0.008 and 0.014). Mean tumor volumes were significantly smaller in CE 3D-CT (29.8 cm3, P = 0.03) and CE 4D-CT (22.8 cm3, P = 0.01) than in 4D-CT (42.0 cm3). Mean tumor motion was comparable in 4D-CT and CE 4D-CT (7.2 and 6.2 mm, P = 0.17). Interobserver variations were comparable in CE 3D-CT and CE 4D-CT (Jaccard index 66.0% and 61.9%, respectively) and were worse for 4D-CT (55.6%) than CE 3D-CT. Conclusions: CE 4D-CT demonstrated characteristics comparable to CE 3D-CT, with high potential for simultaneously delineating the tumor and quantifying tumor motion with a single scan. PMID:27782710
Septic Arthritis of the Temporomandibular Joint--Unusual Presentations.
Lohiya, Sapna; Dillon, Jasjit
2016-01-01
This report describes 2 patients whose septic arthritis of the temporomandibular joint (SATMJ) presented atypically, resulting in treatment delay and complications. A 49-year-old man developed left-side facial allodynia, which was first treated unsuccessfully as trigeminal neuralgia. On day 21, the patient sustained facial trauma from a fall and presented to the emergency department (ED). Maxillofacial contrast-enhanced computed tomographic (CT) scan was suggestive of parotiditis, SATMJ, or hemarthrosis. His condition did not improve with empiric antibiotic treatment. On day 30, contrast-enhanced magnetic resonance imaging (MRI) confirmed SATMJ. Incision and drainage yielded 6 mL of pus and produced clinical improvement. Cultures grew methicillin-resistant Staphylococcus aureus, which was treated with amoxicillin plus clavulanate and sulfamethoxazole plus trimethoprim for 30 days. On day 59, the patient still had slight preauricular pain and CT-proved TMJ osteoarthritic changes. A 56-year-old woman developed right-side facial pain after a crown procedure on her right mandibular second molar. Oral prednisone (and clindamycin) produced partial relief. Her primary physician suspected temporal arteritis, but its biopsy result on day 11 was normal. Gradually, the patient developed trismus and malocclusion refractory to various medicines. On day 49, she presented to the ED. A contrast-enhanced maxillofacial CT scan suggested SATMJ. Incision and drainage yielded 30 mL of pus and produced clinical improvement. During days 50 to 57, the patient received intravenous ampicillin plus sulbactam and metronidazole. However, preauricular tenderness and drainage from the surgical incision persisted. On day 55, CT scan showed a residual abscess. Secondary debridement yielded 5 mL of pus. Culture grew coagulase-negative S aureus. On day 141, the patient still had slight preauricular pain and TMJ osteoarthritic changes on MRI. In these cases, the SATMJ diagnosis was delayed owing to the mildness of local and systemic manifestations, the possibility of confounding conditions, and the rarity of SATMJ. Contrast-enhanced CT and MRI facilitated the diagnosis. Abscess drainage alleviated the symptoms. Postinfectious osteoarthritis developed possibly from treatment delay. SATMJ should be considered in all patients with enigmatic preauricular pain, trismus, or malocclusion. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Ma, Guolin; Bai, Rongjie; Jiang, Huijie; Hao, Xuejia; Ling, Zaisheng; Li, Kefeng
2013-01-01
To develop an optimal scanning protocol for multislice spiral CT perfusion (CTP) imaging to evaluate hemodynamic changes in liver cirrhosis with diethylnitrosamine- (DEN-) induced precancerous lesions. Male Wistar rats were randomly divided into the control group (n = 80) and the precancerous liver cirrhosis group (n = 40). The control group received saline injection and the liver cirrhosis group received 50 mg/kg DEN i.p. twice a week for 12 weeks. All animals underwent plain CT scanning, CTP, and contrast-enhanced CT scanning. Scanning parameters were optimized by adjusting the diatrizoate concentration, the flow rate, and the delivery time. The hemodynamics of both groups was further compared using optimized multislice spiral CTP imaging. High-quality CTP images were obtained with following parameters: 150 kV; 150 mAs; 5 mm thickness, 5 mm interval; pitch, 1; matrix, 512 × 512; and FOV, 9.6 cm. Compared to the control group, the liver cirrhosis group had a significantly increased value of the hepatic arterial fraction and the hepatic artery perfusion (P < 0.05) but significantly decreased hepatic portal perfusion and mean transit time (P < 0.05). Multislice spiral CTP imaging can be used to evaluate the hemodynamic changes in the rat model of liver cirrhosis with precancerous lesions.
Jain, Tarun Kumar; Karunanithi, Sellam; Sharma, Punit; Vijay, Maneesh Kumar; Ballal, Sanjana; Bal, Chandrasekhar
2014-11-01
Isolated asymptomatic brain metastasis in papillary carcinoma thyroid (PCT) is extremely rare. We here present such a case of a 48-year-old woman with PCT. SPECT/CT localized the 131I radiotracer concentration seen on whole-body scan in this patient to the right posterior parietal cortex, suggesting brain metastasis. Contrast-enhanced MRI and 18F-FDG PET/CT confirmed the diagnosis and the patient was taken for gamma-knife radiosurgery. 131I SPECT/CT in this case accurately restaged the patient by detecting asymptomatic isolated brain metastasis and correctly directed the management strategy.
Computed tomography scan - abdomen; CT scan - abdomen; CT abdomen and pelvis ... An abdominal CT scan makes detailed pictures of the structures inside your belly very quickly. This test may be used to look ...
... cervical spine; Computed tomography scan of cervical spine; CT scan of cervical spine; Neck CT scan ... table that slides into the center of the CT scanner. Once you are inside the scanner, the ...
Atean, I; Pointreau, Y; Ouldamer, L; Monghal, C; Bougnoux, A; Bera, G; Barillot, I
2013-02-01
The available contouring guidelines for the supraclavicular and infraclavicular lymph nodes appeared to be inadequate for their delineation on non-enhanced computed tomography (CT) scans. For this purpose, we developed delineation guidelines for the clinical target volumes (CTV) of these lymph nodes on non-enhanced CT-slices performed in the treatment position of breast cancer. A fresh female cadaver study as well as delineation and an anatomical descriptions review were performed to propose a simplified definition of the supra- and infraclavicular lymph nodes using readily identifiable anatomical structures. This definition was developed jointly by breast radiologists, breast surgeons, and radiation oncologists. To validate these guidelines, the primary investigator and seven radiation oncologists (observers) independently delineated 10 different nodal CTVs. The primary investigator contours were considered to be the gold standard contours. Contour accuracy and concordance were evaluated. Written guidelines for the delineation of supra- and infraclavicular lymph nodes CTVs were developed. Consistent contours with minimal variability existed between the delineated volumes; the mean kappa index was 0.83. The mean common contoured and additional contoured volumes were 84.6% and 18.5%, respectively. The mean overlap volume ratio was 0.71. Simplified CT-based atlas for delineation of the supra- and infraclavicular lymph nodes for locoregional irradiation of the breast on non-enhanced CT-scan, have been developed in this study. This atlas provides a consistent set of guidelines for delineating these volumes. Copyright © 2012 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
Total transverse rupture of the duodenum after blunt abdominal trauma.
Pirozzi, Cesare; Di Marco, Carluccio; Loponte, Margherita; Savino, Grazia
2014-05-11
Complete transverse rupture of the duodenum as an isolated lesion in blunt trauma can be considered as exceptional. The aim of this report is to discuss diagnostic procedures and surgical options in such an infrequent presentation. We report on a 37 year old man who had a total transverse rupture of the duodenum after blunt abdominal trauma. Diagnosis was suspected after contrast enhanced CT scan and confirmed at laparotomy; duodenal rupture was repaired by an end to end duodenal-duodenal anastomosis, after Kocher maneuver. The patient had fast and complete recovery. A high index of suspicion is necessary for timely diagnosis. Multi detector contrast enhanced CT scan is the gold standard for that aim. Surgical management must be tailored on an individual basis, since many techniques are available for both reconstruction and duodenum decompression. Kocher maneuver is essential for complete inspection of the pancreatic duodenal block and for appropriate reconstruction. Management of isolated duodenal rupture can be difficult. Contrast enhanced TC scans is essential for timely diagnosis. Primary repair can be achieved by an end to end duodenum anastomosis after Kocher maneuver, although alternative techniques are available for tailored solutions. Complex duodenum decompression techniques are not mandatory.
CAT scan - leg; Computed axial tomography scan - leg; Computed tomography scan - leg; CT scan - leg ... CT scan makes detailed pictures of the body very quickly. The test may help look for: An abscess ...
CAT scan - arm; Computed axial tomography scan - arm; Computed tomography scan - arm; CT scan - arm ... Healing problems or scar tissue following surgery A CT scan may also be used to guide a surgeon ...
Loffroy, Romaric; Lin, MingDe; Yenokyan, Gayane; Rao, Pramod P.; Bhagat, Nikhil; Noordhoek, Niels; Radaelli, Alessandro; Blijd, Järl; Liapi, Eleni
2013-01-01
Purpose: To investigate whether C-arm dual-phase cone-beam computed tomography (CT) performed during transcatheter arterial chemoembolization (TACE) with doxorubicin-eluting beads can help predict tumor response at 1-month follow-up in patients with hepatocellular carcinoma (HCC). Materials and Methods: This prospective study was compliant with HIPAA and approved by the institutional review board and animal care and use committee. Analysis was performed retrospectively on 50 targeted HCC lesions in 29 patients (16 men, 13 women; mean age, 61.9 years ± 10.7) treated with TACE with drug-eluting beads. Magnetic resonance (MR) imaging was performed at baseline and 1 month after TACE. Dual-phase cone-beam CT was performed before and after TACE. Tumor enhancement at dual-phase cone-beam CT in early arterial and delayed venous phases was assessed retrospectively with blinding to MR findings. Tumor response at MR imaging was assessed according to European Association for the Study of the Liver (EASL) guidelines. Two patients were excluded from analysis because dual-phase cone-beam CT scans were not interpretable. Logistic regression models for correlated data were used to compare changes in tumor enhancement between modalities. The radiation dose with dual-phase cone-beam CT was measured in one pig. Results: At 1-month MR imaging follow-up, complete and/or partial tumor response was seen in 74% and 76% of lesions in the arterial and venous phases, respectively. Paired t tests used to compare images obtained before and after TACE showed a significant reduction in tumor enhancement with both modalities (P < .0001). The decrease in tumor enhancement seen with dual-phase cone-beam CT after TACE showed a linear correlation with MR findings. Estimated correlation coefficients were excellent for first (R = 0.89) and second (R = 0.82) phases. A significant relationship between tumor enhancement at cone-beam CT after TACE and complete and/or partial tumor response at MR imaging was found for arterial (odds ratio, 0.95; 95% confidence interval [CI]: 0.91, 0.99; P = .023) and venous (odds ratio, 0.96; 95% CI: 0.93, 0.99; P = .035) phases with the multivariate logistic regression model. Radiation dose for two dual-phase cone-beam CT scans was 3.08 mSv. Conclusion: Intraprocedural C-arm dual-phase cone-beam CT can be used immediately after TACE with doxorubicin-eluting beads to predict HCC tumor response at 1-month MR imaging follow-up. © RSNA, 2012 PMID:23143027
Are facilities following best practices of pediatric abdominal CT scans?
Nosek, Amy E; Hartin, Charles W; Bass, Kathryn D; Glick, Philip L; Caty, Michael G; Dayton, Merril T; Ozgediz, Doruk E
2013-05-01
Established guidelines for pediatric abdominal CT scans include reduced radiation dosage to minimize cancer risk and the use of intravenous (IV) contrast to obtain the highest-quality diagnostic images. We wish to determine if these practices are being used at nonpediatric facilities that transfer children to a pediatric facility. Children transferred to a tertiary pediatric facility over a 16-mo period with abdominal CT scans performed for evaluation of possible appendicitis were retrospectively reviewed for demographics, diagnosis, radiation dosage, CT contrast use, and scan quality. If CT scans were repeated, the radiation dosage between facilities was compared using Student t-test. Ninety-one consecutive children transferred from 29 different facilities had retrievable CT scan images and clinical information. Half of CT scans from transferring institutions used IV contrast. Due to poor quality or inconclusive CT scans, 19 patients required a change in management. Children received significantly less radiation at our institution compared to the referring adult facility for the same body area scanned on the same child (9.7 mSv versus 19.9 mSv, P = 0.0079). Pediatric facilities may be using less radiation per CT scan due to a heightened awareness of radiation risks and specific pediatric CT scanning protocols. The benefits of IV contrast for the diagnostic yield of pediatric CT scans should be considered to obtain the best possible image and to prevent additional imaging. Every facility performing pediatric CT scans should minimize radiation exposure, and pediatric facilities should provide feedback and education to other facilities scanning children. Copyright © 2013 Elsevier Inc. All rights reserved.
Even, Aniek J G; Reymen, Bart; La Fontaine, Matthew D; Das, Marco; Jochems, Arthur; Mottaghy, Felix M; Belderbos, José S A; De Ruysscher, Dirk; Lambin, Philippe; van Elmpt, Wouter
2017-11-01
Most solid tumors contain inadequately oxygenated (i.e., hypoxic) regions, which tend to be more aggressive and treatment resistant. Hypoxia PET allows visualization of hypoxia and may enable treatment adaptation. However, hypoxia PET imaging is expensive, time-consuming and not widely available. We aimed to predict hypoxia levels in non-small cell lung cancer (NSCLC) using more easily available imaging modalities: FDG-PET/CT and dynamic contrast-enhanced CT (DCE-CT). For 34 NSCLC patients, included in two clinical trials, hypoxia HX4-PET/CT, planning FDG-PET/CT and DCE-CT scans were acquired before radiotherapy. Scans were non-rigidly registered to the planning CT. Tumor blood flow (BF) and blood volume (BV) were calculated by kinetic analysis of DCE-CT images. Within the gross tumor volume, independent clusters, i.e., supervoxels, were created based on FDG-PET/CT. For each supervoxel, tumor-to-background ratios (TBR) were calculated (median SUV/aorta SUV mean ) for HX4-PET/CT and supervoxel features (median, SD, entropy) for the other modalities. Two random forest models (cross-validated: 10 folds, five repeats) were trained to predict the hypoxia TBR; one based on CT, FDG, BF and BV, and one with only CT and FDG features. Patients were split in a training (trial NCT01024829) and independent test set (trial NCT01210378). For each patient, predicted, and observed hypoxic volumes (HV) (TBR > 1.2) were compared. Fifteen patients (3291 supervoxels) were used for training and 19 patients (1502 supervoxels) for testing. The model with all features (RMSE training: 0.19 ± 0.01, test: 0.27) outperformed the model with only CT and FDG-PET features (RMSE training: 0.20 ± 0.01, test: 0.29). All tumors of the test set were correctly classified as normoxic or hypoxic (HV > 1 cm 3 ) by the best performing model. We created a data-driven methodology to predict hypoxia levels and hypoxia spatial patterns using CT, FDG-PET and DCE-CT features in NSCLC. The model correctly classifies all tumors, and could therefore, aid tumor hypoxia classification and patient stratification.
Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.
Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P
2005-12-01
Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.
Teh, V; Sim, K S; Wong, E K
2016-11-01
According to the statistic from World Health Organization (WHO), stroke is one of the major causes of death globally. Computed tomography (CT) scan is one of the main medical diagnosis system used for diagnosis of ischemic stroke. CT scan provides brain images in Digital Imaging and Communication in Medicine (DICOM) format. The presentation of CT brain images is mainly relied on the window setting (window center and window width), which converts an image from DICOM format into normal grayscale format. Nevertheless, the ordinary window parameter could not deliver a proper contrast on CT brain images for ischemic stroke detection. In this paper, a new proposed method namely gamma correction extreme-level eliminating with weighting distribution (GCELEWD) is implemented to improve the contrast on CT brain images. GCELEWD is capable of highlighting the hypodense region for diagnosis of ischemic stroke. The performance of this new proposed technique, GCELEWD, is compared with four of the existing contrast enhancement technique such as brightness preserving bi-histogram equalization (BBHE), dualistic sub-image histogram equalization (DSIHE), extreme-level eliminating histogram equalization (ELEHE), and adaptive gamma correction with weighting distribution (AGCWD). GCELEWD shows better visualization for ischemic stroke detection and higher values with image quality assessment (IQA) module. SCANNING 38:842-856, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wahi-Anwar, M; Young, S; Lo, P
Purpose: A method to discriminate different types of renal cell carcinoma (RCC) was developed using attenuation values observed in multiphasic contrast-enhanced CT. This work evaluates the sensitivity of this RCC discrimination task at different CT radiation dose levels. Methods: We selected 5 cases of kidney lesion patients who had undergone four-phase CT scans covering the abdomen to the lilac crest. Through an IRB-approved study, the scans were conducted on 64-slice CT scanners (Definition AS/Definition Flash, Siemens Healthcare) using automatic tube-current modulation (TCM). The protocol included an initial baseline unenhanced scan, followed by three post-contrast injection phases. CTDIvol (32 cm phantom)more » measured between 9 to 35 mGy for any given phase. As a preliminary study, we limited the scope to the cortico-medullary phase—shown previously to be the most discriminative phase. A previously validated method was used to simulate a reduced dose acquisition via adding noise to raw CT sinogram data, emulating corresponding images at simulated doses of 50%, 25%, and 10%. To discriminate the lesion subtype, ROIs were placed in the most enhancing region of the lesion. The mean HU value of an ROI was extracted and used to discriminate to the worst-case RCC subtype, ranked in the order of clear cell, papillary, chromophobe and the benign oncocytoma. Results: Two patients exhibited a change of worst case RCC subtype between original and simulated scans, at 25% and 10% doses. In one case, the worst-case RCC subtype changed from oncocytoma to chromophobe at 10% and 25% doses, while the other case changed from oncocytoma to clear cell at 10% dose. Conclusion: Based on preliminary results from an initial cohort of 5 patients, worst-case RCC subtypes remained constant at all simulated dose levels except for 2 patients. Further study conducted on more patients will be needed to confirm our findings. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH Grant Support from: U01 CA181156.« less
So, Aaron; Imai, Yasuhiro; Nett, Brian; Jackson, John; Nett, Liz; Hsieh, Jiang; Wisenberg, Gerald; Teefy, Patrick; Yadegari, Andrew; Islam, Ali; Lee, Ting-Yim
2016-08-01
The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated from the dynamic contrast-enhanced (DCE) heart images taken at baseline and three weeks after the ischemic insult. Their results showed that the phantom and animal images acquired with the CT platform were minimally affected by image noise and artifacts. For the beam-hardening phantom study, changes in water HU in the wall surrounding the heart chambers greatly reduced from >±30 to ≤ ± 5 HU at all kVp settings except one region at 100 kVp (7 HU). For the cone-beam phantom study, differences in mean water HU from the central slice were less than 5 HU at two peripheral slices with each 4 cm away from the central slice. These findings were reproducible in the pig DCE images at two peripheral slices that were 6 cm away from the central slice. For the partial-scan phantom study, standard deviations of the mean water HU in 10 successive partial scans were less than 5 HU at the central slice. Similar observations were made in the pig DCE images at two peripheral slices with each 6 cm away from the central slice. For the image noise phantom study, CNRs in the ASiR-V images were statistically higher (p < 0.05) than the non-ASiR-V images at all kVp settings. MP maps generated from the porcine DCE images were in excellent quality, with the ischemia in the LAD territory clearly seen in the three orthogonal views. The study demonstrates that this CT system can provide accurate and reproducible CT numbers during cardiac gated acquisitions across a wide axial field of view. This CT number fidelity will enable this imaging tool to assess contrast enhancement, potentially providing valuable added information beyond anatomic evaluation of coronary stenoses. Furthermore, their results collectively suggested that the 100 kVp/25 mAs protocol run on this CT system provides sufficient image accuracy at a low radiation dose (<3 mSv) for whole-heart quantitative CT MP imaging.
Grover, Steven P; Saha, Prakash; Jenkins, Julia; Mukkavilli, Arun; Lyons, Oliver T; Patel, Ashish S; Sunassee, Kavitha; Modarai, Bijan; Smith, Alberto
2015-12-01
The assessment of thrombus size following treatments directed at preventing thrombosis or enhancing its resolution has generally relied on physical or histological methods. This cross-sectional design imposes the need for increased numbers of animals for experiments. Micro-computed tomography (microCT) has been used to detect the presence of venous thrombus in experimental models but has yet to be used in a quantitative manner. In this study, we investigate the use of contrast-enhanced microCT for the longitudinal assessment of experimental venous thrombus resolution. Thrombi induced by stenosis of the inferior vena cava in mice were imaged by contrast-enhanced microCT at 1, 7 and 14 days post-induction (n=18). Thrombus volumes were determined longitudinally by segmentation and 3D volume reconstruction of microCT scans and by standard end-point histological analysis at day 14. An additional group of thrombi were analysed solely by histology at 1, 7 and 14 days post-induction (n=15). IVC resident thrombus was readily detectable by contrast-enhanced microCT. MicroCT-derived measurements of thrombus volume correlated well with time-matched histological analyses (ICC=0.75, P<0.01). Thrombus volumes measured by microCT were significantly greater than those derived from histological analysis (P<0.001). Intra- and inter-observer analyses were highly correlated (ICC=0.99 and 0.91 respectively, P<0.0001). Further histological analysis revealed noticeable levels of contrast agent extravasation into the thrombus that was associated with the presence of neovascular channels, macrophages and intracellular iron deposits. Contrast-enhanced microCT represents a reliable and reproducible method for the longitudinal assessment of venous thrombus resolution providing powerful paired data. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Accuracy of limited four-slice CT-scan in diagnosis of chronic rhinosinusitis.
Zojaji, R; Nekooei, S; Naghibi, S; Mazloum Farsi Baf, M; Jalilian, R; Masoomi, M
2015-12-01
Chronic rhinosinusitis (CRS) is a common chronic health condition worldwide. Standard CT-scan is the method of choice for diagnosis of CRS but its high price and considerable radiation exposure have limited its application. The main goal of this study was to evaluate the accuracy of limited four-slice coronal CT-scan in the diagnosis of CRS. This cross-sectional study was conducted on 46 patients with CRS, for one year, based on American Society of Head and Neck Surgery criteria. All patients received the preoperative standard and four-slice CT-scans, after which endoscopic sinus surgery was performed. Findings of four-slice CT-scans were compared with those of conventional CT-scan and the sensitivity and specificity of four-slice CT-scan and its agreement with conventional CT-scan was calculated. In this study, 46 patients including 32 males (69.6%) and 14 females (30.46%) with a mean age of 33 and standard deviation of 9 years, were evaluated. Sensitivity and specificity of four-slice CT-scan were 97.5% and 100%, respectively. Also, positive predictive value (PPV) and negative predictive value (NPV) of four-slice CT was 100% and 85.71%, respectively. There was a strong agreement between four-slice CT and conventional CT findings. Considering the high sensitivity and specificity of four-slice CT-scan and strong agreement with conventional CT-scan in the diagnosis of CRS and the lower radiation exposure and cost, application of this method is suggested for both diagnosis and treatment follow-up in CRS. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
... Resources Professions Site Index A-Z Computed Tomography (CT) - Body Computed tomography (CT) of the body uses ... of CT Scanning of the Body? What is CT Scanning of the Body? Computed tomography, more commonly ...
Hanna, G G; Van Sörnsen De Koste, J R; Carson, K J; O'Sullivan, J M; Hounsell, A R; Senan, S
2011-10-01
Positron emission tomography (PET)/CT scans can improve target definition in radiotherapy for non-small cell lung cancer (NSCLC). As staging PET/CT scans are increasingly available, we evaluated different methods for co-registration of staging PET/CT data to radiotherapy simulation (RTP) scans. 10 patients underwent staging PET/CT followed by RTP PET/CT. On both scans, gross tumour volumes (GTVs) were delineated using CT (GTV(CT)) and PET display settings. Four PET-based contours (manual delineation, two threshold methods and a source-to-background ratio method) were delineated. The CT component of the staging scan was co-registered using both rigid and deformable techniques to the CT component of RTP PET/CT. Subsequently rigid registration and deformation warps were used to transfer PET and CT contours from the staging scan to the RTP scan. Dice's similarity coefficient (DSC) was used to assess the registration accuracy of staging-based GTVs following both registration methods with the GTVs delineated on the RTP PET/CT scan. When the GTV(CT) delineated on the staging scan after both rigid registration and deformation was compared with the GTV(CT)on the RTP scan, a significant improvement in overlap (registration) using deformation was observed (mean DSC 0.66 for rigid registration and 0.82 for deformable registration, p = 0.008). A similar comparison for PET contours revealed no significant improvement in overlap with the use of deformable registration. No consistent improvements in similarity measures were observed when deformable registration was used for transferring PET-based contours from a staging PET/CT. This suggests that currently the use of rigid registration remains the most appropriate method for RTP in NSCLC.
Morton, Ryan P; Reynolds, Renee M; Ramakrishna, Rohan; Levitt, Michael R; Hopper, Richard A; Lee, Amy; Browd, Samuel R
2013-10-01
In this study, the authors describe their experience with a low-dose head CT protocol for a preselected neurosurgical population at a dedicated pediatric hospital (Seattle Children's Hospital), the largest number of patients with this protocol reported to date. All low-dose head CT scans between October 2011 and November 2012 were reviewed. Two different low-dose radiation dosages were used, at one-half or one-quarter the dose of a standard head CT scan, based on patient characteristics agreed upon by the neurosurgery and radiology departments. Patient information was also recorded, including diagnosis and indication for CT scan. Six hundred twenty-four low-dose head CT procedures were performed within the 12-month study period. Although indications for the CT scans varied, the most common reason was to evaluate the ventricles and catheter placement in hydrocephalic patients with shunts (70%), followed by postoperative craniosynostosis imaging (12%). These scans provided adequate diagnostic imaging, and no patient required a follow-up full-dose CT scan as a result of poor image quality on a low-dose CT scan. Overall physician comfort and satisfaction with interpretation of the images was high. An additional 2150 full-dose head CT scans were performed during the same 12-month time period, making the total number of CT scans 2774. This value compares to 3730 full-dose head CT scans obtained during the year prior to the study when low-dose CT and rapid-sequence MRI was not a reliable option at Seattle Children's Hospital. Thus, over a 1-year period, 22% of the total CT scans were able to be converted to low-dose scans, and full-dose CT scans were able to be reduced by 42%. The implementation of a low-dose head CT protocol substantially reduced the amount of ionizing radiation exposure in a preselected population of pediatric neurosurgical patients. Image quality and diagnostic utility were not significantly compromised.
Novel medical image enhancement algorithms
NASA Astrophysics Data System (ADS)
Agaian, Sos; McClendon, Stephen A.
2010-01-01
In this paper, we present two novel medical image enhancement algorithms. The first, a global image enhancement algorithm, utilizes an alpha-trimmed mean filter as its backbone to sharpen images. The second algorithm uses a cascaded unsharp masking technique to separate the high frequency components of an image in order for them to be enhanced using a modified adaptive contrast enhancement algorithm. Experimental results from enhancing electron microscopy, radiological, CT scan and MRI scan images, using the MATLAB environment, are then compared to the original images as well as other enhancement methods, such as histogram equalization and two forms of adaptive contrast enhancement. An image processing scheme for electron microscopy images of Purkinje cells will also be implemented and utilized as a comparison tool to evaluate the performance of our algorithm.
Brokinkel, Benjamin; Ewelt, Christian; Holling, Markus; Hesselmann, Volker; Heindel, Walter Leonard; Stummer, Walter; Fischer, Bernhard Robert
2013-01-01
To evaluate timing of scheduled CT-scans after burr hole trepanation for chronic subdural hematoma (cSDH). 131 patients with primary cSDH were included. Scheduled CT-scans were performed after burr hole trepanation and placement of a subdural drain. The influence of CT-scanning with or without indwelling drain was analysed regarding subsequent surgery and CT-scans, duration of hospitalization, short- and middle-term follow up by single factor analyses. Subgroup analyses were performed for patients receiving anticoagulant drugs. Median age was 74 years. Routine CT-scans with indwelling drainage were not shown to be beneficial regarding subsequent burr hole trepanations (p=0.243), craniotomies (p=1.000) and outcome at discharge (p=0.297). Mean duration of hospitalization (11 vs. 8 days, p=0.013) was significantly longer and number of subsequent CT-scans was higher when CT scan was performed with indwelling drain (2.3 vs. 1.4, p=0.001). In middle-term follow-up, beneficial effects of CT-scanning with inlaying drainage could neither be shown. Moreover, advantageous effects of CT-scans with indwelling drains could neither be shown for patients receiving anticoagulant drugs. Scheduled postoperative cranial imaging with indwelling drains was not shown to be beneficial and misses information of intracranial damage inflicted by removal of drains. We thus recommend CT-scanning after drainage removal.
An open library of CT patient projection data
NASA Astrophysics Data System (ADS)
Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Holmes, David; Fletcher, Joel; McCollough, Cynthia
2016-03-01
Lack of access to projection data from patient CT scans is a major limitation for development and validation of new reconstruction algorithms. To meet this critical need, we are building a library of CT patient projection data in an open and vendor-neutral format, DICOM-CT-PD, which is an extended DICOM format that contains sinogram data, acquisition geometry, patient information, and pathology identification. The library consists of scans of various types, including head scans, chest scans, abdomen scans, electrocardiogram (ECG)-gated scans, and dual-energy scans. For each scan, three types of data are provided, including DICOM-CT-PD projection data at various dose levels, reconstructed CT images, and a free-form text file. Several instructional documents are provided to help the users extract information from DICOM-CT-PD files, including a dictionary file for the DICOM-CT-PD format, a DICOM-CT-PD reader, and a user manual. Radiologist detection performance based on the reconstructed CT images is also provided. So far 328 head cases, 228 chest cases, and 228 abdomen cases have been collected for potential inclusion. The final library will include a selection of 50 head, chest, and abdomen scans each from at least two different manufacturers, and a few ECG-gated scans and dual-source, dual-energy scans. It will be freely available to academic researchers, and is expected to greatly facilitate the development and validation of CT reconstruction algorithms.
Mohammed, Noorullah Naqvi; Pandey, Pankaj; Khan, Nayaab S; Elokely, Khaled M; Liu, Haining; Doerksen, Robert J; Repka, Michael A
2016-08-01
Clotrimazole (CT) is a poorly soluble antifungal drug that is most commonly employed as a topical treatment in the management of vaginal candidiasis. The present work focuses on a formulation approach to enhance the solubility of CT using cyclodextrin (CD) complexation. A CT-CD complex was prepared by a co-precipitation method. Various characterization techniques such as differential scanning calorimetry, infrared (IR) and X-ray spectroscopy, scanning electron microscopy and nuclear magnetic resonance (NMR) spectroscopy were performed to evaluate the complex formation and to understand the interactions between CT and CD. Computational molecular modeling was performed using the Schrödinger suite and Gaussian 09 program to understand structural conformations of the complex. The phase solubility curve followed an AL-type curve, indicating formation of a 1:1 complex. Molecular docking studies supported the data obtained through NMR and IR studies. Enthalpy changes confirmed that complexation was an exothermic and enthalpically favorable phenomenon. The CT-CD complexes were formulated in a gel and evaluated for release and antifungal activity. The in vitro release studies performed using gels demonstrated a sustained release of CT from the CT-CD complex with the complex exhibiting improved release relative to the un-complexed CT. Complexed CT-CD exhibited better fungistatic activity toward different Candida species than un-complexed CT.
Öğrenci, Ahmet; Koban, Orkun; Ekşi, Murat; Yaman, Onur; Dalbayrak, Sedat
2017-01-01
AIM: This study aimed to make a retrospective analysis of pediatric patients with head traumas that were admitted to one hospital setting and to make an analysis of the patients for whom follow-up CT scans were obtained. METHODS: Pediatric head trauma cases were retrospectively retrieved from the hospital’s electronic database. Patients’ charts, CT scans and surgical notes were evaluated by one of the authors. Repeat CT scans for operated patients were excluded from the total number of repeat CT scans. RESULTS: One thousand one hundred and thirty-eight pediatric patients were admitted to the clinic due to head traumas. Brain CT scan was requested in 863 patients (76%) in the cohort. Follow-up brain CT scans were obtained in 102 patients. Additional abnormal finding requiring surgical intervention was observed in only one patient (isolated 4th ventricle hematoma) on the control CTs (1% of repeat CT scans), who developed obstructive hydrocephalus. None of the patients with no more than 1 cm epidural hematoma in its widest dimension and repeat CT scans obtained 1.5 hours after the trauma necessitated surgery. CONCLUSION: Follow-up CT scans changed clinical approach in only one patient in the present series. When ordering CT scan in the follow-up of pediatric traumas, benefits and harms should be weighted based upon time interval from trauma onset to initial CT scan and underlying pathology. PMID:29104682
2017-01-01
A large number of studies support the increasingly relevant prognostic value of the presence and extent of delayed enhancement (DE), a surrogate marker of fibrosis, in diverse etiologies. Gadolinium and iodinated based contrast agents share similar kinetics, thus leading to comparable myocardial characterization with cardiac magnetic resonance (CMR) and cardiac computed tomography (CT) at both first-pass perfusion and DE imaging. We review the available evidence of DE imaging for the assessment of myocardial infarction (MI) using cardiac CT (CTDE), from animal to clinical studies, and from 16-slice CT to dual-energy CT systems (DECT). Although both CMR and gadolinium agents have been originally deemed innocuous, a number of concerns (though inconclusive and very rare) have been recently issued regarding safety issues, including DNA double-strand breaks related to CMR, and gadolinium-associated nephrogenic systemic fibrosis and deposition in the skin and certain brain structures. These concerns have to be considered in the context of non-negligible rates of claustrophobia, increasing rates of patients with implantable cardiac devices, and a number of logistic drawbacks compared with CTDE, such as higher costs, longer scanning times, and difficulties to scan patients with impaired breath-holding capabilities. Overall, these issues might encourage the role of CTDE as an alternative for DE-CMR in selected populations. PMID:28540211
Wolthaus, J W H; Sonke, J J; van Herk, M; Damen, E M F
2008-09-01
lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods < 0.5 mm for all directions) for the tumor region. From visual assessment, the registration was good for the clearly visible features (e.g., tumor and diaphragm). The shape of the tumor, with respect to that of the BH CT scan, was better represented by the MidP reconstructions than any of the 4D CT frames (including MidV; reduction of "shape differences" was 66%). The MidP scans contained about one-third the noise of individual 4D CT scan frames. We implemented an accurate method to estimate the motion of structures in a 4D CT scan. Subsequently, a novel method to create a midposition CT scan (time-weighted average of the anatomy) for treatment planning with reduced noise and artifacts was introduced. Tumor shape and position in the MidP CT scan represents that of the BH CT scan better than MidV CT scan and, therefore, was found to be appropriate for treatment planning.
Utility of CT-compatible EEG electrodes in critically ill children.
Abend, Nicholas S; Dlugos, Dennis J; Zhu, Xiaowei; Schwartz, Erin S
2015-04-01
Electroencephalographic monitoring is being used with increasing frequency in critically ill children who may require frequent and sometimes urgent brain CT scans. Standard metallic disk EEG electrodes commonly produce substantial imaging artifact, and they must be removed and later reapplied when CT scans are indicated. To determine whether conductive plastic electrodes caused artifact that limited CT interpretation. We describe a retrospective cohort of 13 consecutive critically ill children who underwent 17 CT scans with conductive plastic electrodes during 1 year. CT images were evaluated by a pediatric neuroradiologist for artifact presence, type and severity. All CT scans had excellent quality images without artifact that impaired CT interpretation except for one scan in which improper wire placement resulted in artifact. Conductive plastic electrodes do not cause artifact limiting CT scan interpretation and may be used in critically ill children to permit concurrent electroencephalographic monitoring and CT imaging.
CAT scan - lumbar spine; Computed axial tomography scan - lumbar spine; Computed tomography scan - lumbar spine; CT - lower back ... CT scans rapidly makes detailed pictures of the lower back. The test may be used to look for: ...
NASA Astrophysics Data System (ADS)
Cho, Hyo Sung; Woo, Tae Ho; Park, Chul Kyu
2016-10-01
Using the metal artifact property, it is analyzed for the X-ray computed tomography (CT) in the aspect of the security on the examined places like airport and surveillance areas. Since the importance of terror prevention strategy has been increased, the security application of X-ray CT has the significant remark. One shot X-ray image has the limitation to find out the exact shape to property in the closed box, which could be solved by the CT scanning without the tearing off the box in this work. Cleaner images can be obtained by the advanced technology if the CT scanning is utilized in the security purposes on the secured areas. A metal sample is treated by the metal artifact removal (MAR) method for the enhanced image. The mimicked explosive is experimented for the imaging processing application where the cleaner one is obtained. The procedure is explained and the further study is discussed.
Lung imaging of laboratory rodents in vivo
NASA Astrophysics Data System (ADS)
Cody, Dianna D.; Cavanaugh, Dawn; Price, Roger E.; Rivera, Belinda; Gladish, Gregory; Travis, Elizabeth
2004-10-01
We have been acquiring respiratory-gated micro-CT images of live mice and rats for over a year with our General Electric (formerly Enhanced Vision Systems) hybrid scanner. This technique is especially well suited for the lung due to the inherent high tissue contrast. Our current studies focus on the assessment of lung tumors and their response to experimental agents, and the assessment of lung damage due to chemotherapy agents. We have recently installed a custom-built dual flat-panel cone-beam CT scanner with the ability to scan laboratory animals that vary in size from mice to large dogs. A breath-hold technique is used in place of respiratory gating on this scanner. The objective of this pilot study was to converge on scan acquisition parameters and optimize the visualization of lung damage in a mouse model of fibrosis. Example images from both the micro-CT scanner and the flat-panel CT scanner will be presented, as well as preliminary data describing spatial resolution, low contrast resolution, and radiation dose parameters.
Rhoades, Glendon W; Belev, George S; Chapman, L Dean; Wiebe, Sheldon P; Cooper, David M; Wong, Adelaine TF; Rosenberg, Alan M
2015-01-01
The objective of this project was to develop and test a new technology for imaging growing joints by means of diffraction-enhanced imaging (DEI) combined with CT and using a synchrotron radiation source. DEI–CT images of an explanted 4-wk-old piglet stifle joint were acquired by using a 40-keV beam. The series of scanned slices was later ‘stitched’ together, forming a 3D dataset. High-resolution DEI-CT images demonstrated fine detail within all joint structures and tissues. Striking detail of vasculature traversing between bone and cartilage, a characteristic of growing but not mature joints, was demonstrated. This report documents for the first time that DEI combined with CT and a synchrotron radiation source can generate more detailed images of intact, growing joints than can currently available conventional imaging modalities. PMID:26310464
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Sun Mo, E-mail: Sunmo.Kim@rmp.uhn.on.ca; Haider, Masoom A.; Jaffray, David A.
Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarselymore » sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.« less
Arterial wall perfusion measured with photon counting spectral x-ray CT
NASA Astrophysics Data System (ADS)
Jorgensen, Steven M.; Korinek, Mark J.; Vercnocke, Andrew J.; Anderson, Jill L.; Halaweish, Ahmed; Leng, Shuai; McCollough, Cynthia H.; Ritman, Erik L.
2016-10-01
Early atherosclerosis changes perfusion of the arterial wall due to localized proliferation of the vasa vasorum. When contrast agent passes through the artery, some enters the vasa vasorum and increases radiopacity of the arterial wall. Technical challenges to detecting changes in vasa vasorum density include the thin arterial wall, partial volume averaging at the arterial lumen/wall interface and calcification within the wall. We used a photon-counting spectral CT scanner to study carotid arteries of anesthetized pigs and micro-CT of these arteries to quantify vasa vasorum density. The left carotid artery wall was injected with autologous blood to stimulate vasa vasorum angiogenesis. The scans were performed at 25-120 keV; the tube-current-time product was 550 mAs. A 60 mL bolus of iodine contrast agent was injected into the femoral vein at 5mL/s. Two seconds post injection, an axial scan was acquired at every 3 s over 60 s (i.e., 20 time points). Each time point acquired 28 contiguous transaxial slices with reconstructed voxels 0.16 x 0.16 x 1 mm3. Regions-of-interest in the outer 2/3 of the arterial wall and in the middle 2/3 of the lumen were drawn and their enhancements plotted versus time. Lumenal CT values peaked several seconds after injection and then returned towards baseline. Arterial wall CT values peaked concurrent to the lumen. The peak arterial wall enhancement in the left carotid arterial wall correlated with increased vasa vasorum density observed in micro-CT images of the isolated arteries.
Arterial Wall Perfusion Measured with Photon Counting Spectral X-ray CT.
Jorgensen, Steven M; Korinek, Mark J; Vercnocke, Andrew J; Anderson, Jill L; Halaweish, Ahmed; Leng, Shuai; McCollough, Cynthia H; Ritman, Erik L
2016-08-28
Early atherosclerosis changes perfusion of the arterial wall due to localized proliferation of the vasa vasorum. When contrast agent passes through the artery, some enters the vasa vasorum and increases radiopacity of the arterial wall. Technical challenges to detecting changes in vasa vasorum density include the thin arterial wall, partial volume averaging at the arterial lumen/wall interface and calcification within the wall. We used a photon-counting spectral CT scanner to study carotid arteries of anesthetized pigs and micro-CT of these arteries to quantify vasa vasorum density. The left carotid artery wall was injected with autologous blood to stimulate vasa vasorum angiogenesis. The scans were performed at 25-120 keV; the tube-current-time product was 550 mAs. A 60 mL bolus of iodine contrast agent was injected into the femoral vein at 5mL/s. Two seconds post injection, an axial scan was acquired at every 3 s over 60 s (i.e., 20 time points). Each time point acquired 28 contiguous transaxial slices with reconstructed voxels 0.16 × 0.16 × 1 mm 3 . Regions-of-interest in the outer 2/3 of the arterial wall and in the middle 2/3 of the lumen were drawn and their enhancements plotted versus time. Lumenal CT values peaked several seconds after injection and then returned towards baseline. Arterial wall CT values peaked concurrent to the lumen. The peak arterial wall enhancement in the left carotid arterial wall correlated with increased vasa vasorum density observed in micro-CT images of the isolated arteries.
Wu, Guofeng; Shen, Zhengkui; Wang, Likun; Sun, Shujie; Luo, Jinbiao; Mao, Yuanhong
2017-07-06
Intracranial post-operative re-haemorrhage is an important complication in patients with hypertensive intracerebral haemorrhage (ICH). The purpose of the present study was to determine the value of the computed tomography (CT) blend sign in predicting post-operative re-haemorrhage in patients with ICH. A total of 126 patients with ICH were included in the present study. All the patients underwent standard stereotactic minimally invasive surgery(MIS) to remove the ICH within 24 h following admission. There were 41 patients with a blend sign on initial CT and 85 patients without a blend sign on the initial CT. Multivariable logistic regression analyses were performed to assess the relationship between the presence of the blend sign on the non-enhanced admission CT scan and post-operative re-haemorrhage. Post-operative re-haemorrhage occurred in 24 of the 41 patients with the blend sign, and in 9 of the 85 patients without the blend sign. The incidence of re-haemorrhage was significantly different between the groups. The multivariate logistic regression analysis demonstrated that the initial Glasgow coma scale score (p = 0.002) and blend sign (P < 0.00) on the initial CT scan are independent predictors of post-operative re-haemorrhage. The sensitivity, specificity, and positive and negative predictive values of the blend sign for predicting post-operative re-haemorrhage were 72.7, 81.7, 58.5 and 89.4%, respectively. The presence of the blend sign on the initial CT scan is closely associated with post-operative re-haemorrhage in patients with ICH who undergo stereotactic MIS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, W; Xue, M; Lane, B
Purpose: To develop an individually optimized contrast-enhanced (CE) 4D-CT for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). Methods: Ten PDA patients were enrolled. Each underwent 3 CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT using test injection. Three physicians contoured the tumor and pancreatic tissues. We compared image quality scores, tumor volume, motion, tumor-to-pancreas contrast, and contrast-to-noise ratio (CNR) in the 3 CTs. We also evaluated interobserver variations in contouring the tumor using simultaneous truth and performance level estimation (STAPLE). Results: Average image quality scores for CE 3DCT and CE 4D-CT were comparablemore » (4.0 and 3.8, respectively; P=0.47), and both were significantly better than that for 4D-CT (2.6, P<0.001). Tumor-to-pancreas contrast results were comparable in CE 3D-CT and CE 4D-CT (15.5 and 16.7 HU, respectively; P=0.71), and the latter was significantly higher than in 4D-CT (9.2 HU, P=0.03). Image noise in CE 3D-CT (12.5 HU) was significantly lower than in CE 4D-CT (22.1 HU, P<0.001) and 4D-CT (19.4 HU, P=0.005). CNRs were comparable in CE 3D-CT and CE 4DCT (1.4 and 0.8, respectively; P=0.23), and the former was significantly better than in 4D-CT (0.6, P = 0.04). Mean tumor volumes were smaller in CE 3D-CT (29.8 cm{sup 3}) and CE 4D-CT (22.8 cm{sup 3}) than in 4D-CT (42.0 cm{sup 3}), although these differences were not statistically significant. Mean tumor motion was comparable in 4D-CT and CE 4D-CT (7.2 and 6.2 mm, P=0.23). Interobserver variations were comparable in CE 3D-CT and CE 4D-CT (Jaccard index 66.0% and 61.9%, respectively) and were worse for 4D-CT (55.6%) than CE 3D-CT. Conclusion: CE 4D-CT demonstrated characteristics comparable to CE 3D-CT, with high potential for simultaneously delineating the tumor and quantifying tumor motion with a single scan. Supported in part by Philips Healthcare.« less
Hamami, Monia E; Poeppel, Thorsten D; Müller, Stephan; Heusner, Till; Bockisch, Andreas; Hilgard, Philipp; Antoch, Gerald
2009-05-01
Radioembolization with (90)Y microspheres is a novel treatment for hepatic tumors. Generally, hepatic arteriography and (99m)Tc-macroaggregated albumin (MAA) scanning are performed before selective internal radiation therapy to detect extrahepatic shunting to the lung or the gastrointestinal tract. Whereas previous studies have used only planar or SPECT scans, the present study used (99m)Tc-MAA SPECT/CT scintigraphy (SPECT with integrated low-dose CT) to evaluate whether SPECT/CT and additional diagnostic contrast-enhanced CT before radioembolization with (90)Y microspheres are superior to SPECT or planar imaging alone for detection of gastrointestinal shunting. In a prospective study, we enrolled 58 patients (mean age, 66 y; SD, 12 y; 10 women and 48 men) with hepatocellular carcinoma who underwent hepatic arteriography and scintigraphy with (99m)Tc-MAA using planar imaging, SPECT, and SPECT with integrated low-dose CT of the upper abdomen (acquired with a hybrid SPECT/CT camera). The ability of the different imaging modalities to detect extrahepatic MAA shunting was compared. Patient follow-up of a mean of 180 d served as the standard of reference. Gastrointestinal shunting was revealed by planar imaging in 4, by SPECT in 9, and by SPECT/CT in 16 of the 68 examinations. For planar imaging, the sensitivity for detection of gastrointestinal shunting was 25%, the specificity 87%, and the accuracy 72%. For SPECT without CT, the sensitivity was 56%, the specificity 87%, and the accuracy 79%. SPECT with CT fusion had a sensitivity of 100%, a specificity of 94%, and an accuracy of 96%. In 3 patients, MAA deposits in the portal vein could accurately be attributed to tumor thrombus only with additional information from contrast-enhanced CT. The follow-up did not show any gastrointestinal complications. SPECT with integrated low-dose CT using (99m)Tc-MAA is beneficial in radioembolization with (90)Y microspheres because it increases the sensitivity and specificity of (99m)Tc-MAA SPECT when detecting extrahepatic arterial shunting. The overall low risk of gastrointestinal complications in radioembolization may therefore be further reduced by SPECT/CT.
Sun, Z; Al Ghamdi, KS; Baroum, IH
2012-01-01
Purpose: To investigate whether the multislice CT scanning protocols of head, chest and abdomen are adjusted according to patient’s age in paediatric patients. Materials and Methods: Multislice CT examination records of paediatric patients undergoing head, chest and abdomen scans from three public hospitals during a one-year period were retrospectively reviewed. Patients were categorised into the following age groups: under 4 years, 5–8 years, 9–12 years and 13–16 years, while the tube current was classified into the following ranges: < 49 mA, 50–99 mA, 100–149 mA, 150–199 mA, > 200 mA and unknown. Results: A total of 4998 patient records, comprising a combination of head, chest and abdomen CT scans, were assessed, with head CT scans representing nearly half of the total scans. Age-based adjusted CT protocols were observed in most of the scans with higher tube current setting being used with increasing age. However, a high tube current (150–199 mA) was still used in younger patients (0–8 years) undergoing head CT scans. In one hospital, CT protocols remained constant across all age groups, indicating potential overexposure to the patients. Conclusion: This analysis shows that paediatric CT scans are adjusted according to the patient’s age in most of the routine CT examinations. This indicates increased awareness regarding radiation risks associated with CT. However, high tube current settings are still used in younger patient groups, thus, optimisation of paediatric CT protocols and implementation of current guidelines, such as age-and weight-based scanning, should be recommended in daily practice. PMID:22970059
Tomizawa, Minoru; Shinozaki, Fuminobu; Tanaka, Satomi; Sunaoshi, Takafumi; Kano, Daisuke; Sugiyama, Eriko; Shite, Misaki; Haga, Ryouta; Fukamizu, Yoshiya; Fujita, Toshiyuki; Kagayama, Satoshi; Hasegawa, Rumiko; Shirai, Yoshinori; Motoyoshi, Yasufumi; Sugiyama, Takao; Yamamoto, Shigenori; Ishige, Naoki
2017-07-01
In a clinical setting, it is important to diagnose complications of acute cholecystitis accurately. Diffusion-weighted whole body imaging with background body signal suppression/T2-weighted image fusion (DWIBS/T2) provides high signal intensity with a strong contrast against surrounding tissues in anatomical settings. In the present study, patients who were being treated for acute cholecystitis and underwent DWIBS/T2 in the National Hospital Organization Shimoshizu Hospital between December 2012 and August 2015 were enrolled. A total of 10 men and 4 women underwent DWIBS/T2. Records, including DWIBS/T2 and computed tomography (CT) imaging, were retrospectively analyzed for patients with acute cholecystitis. CT images revealed thickened gallbladder walls in patients with acute cholecystitis, and high signal intensity was observed in DWIBS/T2 images for the thickened gallbladder wall. Inflammation of the pericholecystic space and the liver resulted in high intensity signals with DWIBS/T2 imaging, whereas CT imaging revealed a low-density area in the cholecystic space. Plain CT scanning identified a low-density area in the liver, which became more obvious with contrast-enhanced CT. DWIBS/T2 imaging showed the inflammation of the liver and pericholesyctic space as an area of high signal intensity. Detectability of inflammation of the pericholecystic space and the liver was the same for DWIBS/T2 and CT, which suggests that DWIBS/T2 has the same sensitivity as CT scanning for the diagnosis of complicated acute cholecystitis. However, the strong contrast shown by DWIBS/T2 allows for easier evaluation of acute cholecystitis than CT scanning.
Low Yield of Paired Head and Cervical Spine Computed Tomography in Blunt Trauma Evaluation.
Graterol, Joseph; Beylin, Maria; Whetstone, William D; Matzoll, Ashleigh; Burke, Rennie; Talbott, Jason; Rodriguez, Robert M
2018-06-01
With increased computed tomography (CT) utilization, clinicians may simultaneously order head and neck CT scans, even when injury is suspected only in one region. We sought to determine: 1) the frequency of simultaneous ordering of a head CT scan when a neck CT scan is ordered; 2) the yields of simultaneously ordered head and neck CT scans for clinically significant injury (CSI); and 3) whether injury in one region is associated with a higher rate of injury in the other. This was a retrospective study of all adult patients who received neck CT scans (and simultaneously ordered head CT scans) as part of their blunt trauma evaluation at an urban level 1 trauma center in 2013. An expert panel determined CSI of head and neck injuries. We defined yield as number of patients with injury/number of patients who had a CT scan. Of 3223 patients who met inclusion criteria, 2888 (89.6%) had simultaneously ordered head and neck CT scans. CT yield for CSI in both the head and neck was 0.5% (95% confidence interval [CI] 0.3-0.8%), and the yield for any injury in both the head and neck was 1.4% (95% CI 1.0-1.8%). The yield for CSI in one region was higher when CSI was seen in the other region. The yield of CT for CSI in both the head and neck concomitantly is very low. When injury is seen in one region, there is higher likelihood of injury in the other. These findings argue against paired ordering of head and neck CT scans and suggest that CT scans should be ordered individually or when injury is detected in one region. Copyright © 2018 Elsevier Inc. All rights reserved.
CT contrast predicts pancreatic cancer treatment response to verteporfin-based photodynamic therapy
NASA Astrophysics Data System (ADS)
Jermyn, Michael; Davis, Scott C.; Dehghani, Hamid; Huggett, Matthew T.; Hasan, Tayyaba; Pereira, Stephen P.; Bown, Stephen G.; Pogue, Brian W.
2014-04-01
The goal of this study was to determine dominant factors affecting treatment response in pancreatic cancer photodynamic therapy (PDT), based on clinically available information in the VERTPAC-01 trial. This trial investigated the safety and efficacy of verteporfin PDT in 15 patients with locally advanced pancreatic adenocarcinoma. CT scans before and after contrast enhancement from the 15 patients in the VERTPAC-01 trial were used to determine venous-phase blood contrast enhancement and this was correlated with necrotic volume determined from post-treatment CT scans, along with estimation of optical absorption in the pancreas for use in light modeling of the PDT treatment. Energy threshold contours yielded estimates for necrotic volume based on this light modeling. Both contrast-derived venous blood content and necrotic volume from light modeling yielded strong correlations with observed necrotic volume (R2 = 0.85 and 0.91, respectively). These correlations were much stronger than those obtained by correlating energy delivered versus necrotic volume in the VERTPAC-01 study and in retrospective analysis from a prior clinical study. This demonstrates that contrast CT can provide key surrogate dosimetry information to assess treatment response. It also implies that light attenuation is likely the dominant factor in the VERTPAC treatment response, as opposed to other factors such as drug distribution. This study is the first to show that contrast CT provides needed surrogate dosimetry information to predict treatment response in a manner which uses standard-of-care clinical images, rather than invasive dosimetry methods.
Khattab, Mona; Walker, Dale M; Albertini, Richard J; Nicklas, Janice A; Lundblad, Lennart K A; Vacek, Pamela M; Walker, Vernon E
2017-08-01
The use of computed tomography (CT scans) has increased dramatically in recent decades, raising questions about the long-term safety of CT-emitted x-rays especially in infants who are more sensitive to radiation-induced effects. Cancer risk estimates for CT scans typically are extrapolated from models; therefore, new approaches measuring actual DNA damage are needed for improved estimations. Hence, changes in a dosimeter of DNA double-strand breaks, micronucleated reticulocytes (MN-RETs) measured by flow cytometry, were investigated in mice and infants exposed to CT scans. In male C57BL/6N mice (6-8 weeks-of-age), there was a dose-related increase in MN-RETs in blood samples collected 48h after CT scans delivering targeted exposures of 1-130 cGy x-rays (n=5-10/group, r=0.994, p=0.01), with significant increases occurring at exposure levels as low as 0.83 cGy x-rays compared to control mice (p=0.002). In paired blood specimens from infants with no history of a prior CT scan, there was no difference in MN-RET frequencies found 2h before (mean, 0.10±0.07%) versus 48h after (mean, 0.11±0.05%) a scheduled CT scan/cardiac catheterization. However, in infants having prior CT scan(s), MN-RET frequencies measured at 48h after a scheduled CT scan (mean=0.22±0.12%) were significantly higher than paired baseline values (mean, 0.17±0.07%; p=0.032). Increases in baseline (r=0.722, p<0.001) and 48-h post exposure (r=0.682, p<0.001) levels of MN-RETs in infants with a history of prior CT scans were significantly correlated with the number of previous CT scans. These preliminary findings suggest that prior CT scans increase the cellular responses to subsequent CT exposures. Thus, further investigation is needed to characterize the potential cancer risk from single versus repeated CT scans or cardiac catheterizations in infants. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Matsukiyo, Hiroshi; Sato, Eiichi; Hagiwara, Osahiko; Abudurexiti, Abulajiang; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Nagao, Jiro; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2011-03-01
A linear cadmium telluride (CdTe) detector is useful for carrying out energy-discrimination X-ray imaging, including computed tomography (CT). To perform enhanced gadolinium K-edge CT, we used an oscillation-type linear CdTe detector with an energy resolution of 1.2 keV. CT is performed by repeating the linear scan and the rotation of an object. Penetrating X-ray photons from the object are detected by the CdTe detector, and event signals of X-ray photons are produced using charge-sensitive and shaping amplifiers. Both the photon energy and the energy width are selected using a multichannel analyzer, and the number of photons is counted by a counter card. In energy-discrimination CT, tube voltage and current were 80 kV and 20 μA, respectively, and X-ray intensity was 1.55 μGy/s at 1.0 m from the source at a tube voltage of 80 kV. Demonstration of enhanced gadolinium K-edge X-ray CT was carried out by selecting photons with energies just beyond gadolinium K-edge energy of 50.3 keV.
Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Fukuyama, Naoki; Yokoi, Takahiro; Kido, Tomoyuki; Uetani, Teruyoshi; Vembar, Mani; Dhanantwari, Amar; Tokuyasu, Shinichi; Yamashita, Natsumi; Mochizuki, Teruhito
2017-10-01
We evaluated the image quality and diagnostic performance of late iodine enhancement computed tomography (LIE-CT) with knowledge-based iterative model reconstruction (IMR) for the detection of myocardial infarction (MI) in comparison with late gadolinium enhancement magnetic resonance imaging (LGE-MRI). The study investigated 35 patients who underwent a comprehensive cardiac CT protocol and LGE-MRI for the assessment of coronary artery disease. The CT protocol consisted of stress dynamic myocardial CT perfusion, coronary CT angiography (CTA) and LIE-CT using 256-slice CT. LIE-CT scans were acquired 5 min after CTA without additional contrast medium and reconstructed with filtered back projection (FBP), a hybrid iterative reconstruction (HIR), and IMR. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed. Sensitivity and specificity of LIE-CT for detecting MI were assessed according to the 16-segment model. Image quality scores, and diagnostic performance were compared among LIE-CT with FBP, HIR and IMR. Among the 35 patients, 139 of 560 segments showed MI in LGE-MRI. On LIE-CT with FBP, HIR, and IMR, the median SNRs were 2.1, 2.9, and 6.1; and the median CNRs were 1.7, 2.2, and 4.7, respectively. Sensitivity and specificity were 56 and 93% for FBP, 62 and 91% for HIR, and 80 and 91% for IMR. LIE-CT with IMR showed the highest image quality and sensitivity (p < 0.05). The use of IMR enables significant improvement of image quality and diagnostic performance of LIE-CT for detecting MI in comparison with FBP and HIR.
He, Hongying; Cai, Chunyan; Charnsangavej, Chusilp; Theriault, Richard L; Green, Marjorie; Quraishi, Mohammad A; Yang, Wei T
2015-11-01
To evaluate change in size vs computed tomography (CT) density of hepatic metastases in breast cancer patients before and after cytotoxic chemotherapy or targeted therapy. A database search in a single institution identified 48 breast cancer patients who had hepatic metastases treated with either cytotoxic chemotherapy alone or targeted therapy alone, and who had contrast-enhanced CT (CECT) scans of the abdomen at baseline and within 4 months of initiation of therapy in the past 10 years. Two radiologists retrospectively evaluated CT scans and identified up to 2 index lesions in each patient. The size (centimeters) of each lesion was measured according to Response Evaluation Criteria in Solid Tumors (RECIST) criteria, and CT density (Hounsfield units) was measured by drawing a region of interest around the margin of the entire lesion. The percent change in sum of lesion size and mean CT density on pre- and post-treatment scans was computed for each patient; results were compared within each treatment group. Thirty-nine patients with 68 lesions received cytotoxic chemotherapy only; 9 patients with 15 lesions received targeted therapy only. The mean percent changes in sum of lesion size and mean CT density were statistically significant within the cytotoxic chemotherapy group before and after treatment, but not significant in the targeted therapy group. The patients in the targeted therapy group tend to have better 2-year survival. The patients who survived at 2 years tend to have more decrease in tumour size in the cytotoxic chemotherapy group. Cytotoxic chemotherapy produced significant mean percent decrease in tumour size and mean CT density of hepatic metastases from breast cancer before and after treatment, whereas targeted therapy did not. Nonetheless, there is a trend that the patients in the targeted therapy group had better 2-year survival rate. This suggests that RECIST is potentially inadequate in evaluating tumour response in breast cancer liver metastases treated with targeted therapy alone, calling for an alternative marker for response evaluation in this subset of patients. Copyright © 2015 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Schwartz, A; Gospodarowicz, M K; Khalili, K; Pintilie, M; Goddard, S; Keller, A; Tsang, R W
2006-02-01
The purpose of this study was to assist with resource planning by examining the pattern of physician utilization of imaging procedures for lymphoma patients in a dedicated oncology hospital. The proportion of imaging tests ordered for routine follow up with no specific clinical indication was quantified, with specific attention to CT scans. A 3-month audit was performed. The reasons for ordering all imaging procedures (X-rays, CT scans, ultrasound, nuclear scan and MRI) were determined through a retrospective chart review. 411 lymphoma patients had 686 assessments (sets of imaging tests) and 981 procedures (individual imaging tests). Most procedures were CT scans (52%) and chest radiographs (30%). The most common reasons for ordering imaging were assessing response (23%), and investigating new symptoms (19%). Routine follow up constituted 21% of the assessments (142/686), and of these, 82% were chest radiographs (116/142), while 24% (34/142) were CT scans. With analysis restricted to CT scans (296 assessments in 248 patients), the most common reason for ordering CT scans were response evaluation (40%), and suspicion of recurrence and/or new symptom (23%). Follow-up CT scans done with no clinical indication comprised 8% (25/296) of all CT assessments. Staging CT scans were under-represented at 6% of all assessments. Imaging with CT scans for follow up of asymptomatic patients is infrequent. However, scans done for staging new lymphoma patients were unexpectedly low in frequency, due to scans done elsewhere prior to referral. This analysis uncovered utilization patterns, helped resource planning and provided data to reduce unnecessary imaging procedures.
The Stranded Stone: Relationship Between Acute Appendicitis and Appendicolith
Aljefri, Ahmad; Al-Nakshabandi, Nizar
2009-01-01
Background/Aim: To examine the relationship between acute appendicitis and the presence of an appendicolith in abdominal CT scans of patients attending emergency services. Materials and Methods: Abdominal CT scan reports were retrospectively reviewed for 267 patients through the PACS database. A 16-slices MDCT GE Light Speed scanner (Milwaukee WI) was used with a scanning protocol of 5 mm axial collimation and a pitch of 1.0, along with oral contrast material (Gastrografin 3.7% diatrizoate meglumine) and 140 mL of intravenous (IV) nonionic contrast material (Omnipaque). Particular attention was given to the study protocol, patients' age, and gender. Statistical Analysis: We used MS-EXCEL and SPSS version 12.0 to perform chi-square and Fisher's exact tests. Bookends and Papers, components in Mac OS X software, were used for literature reviews and the organization of results. Results: Two hundred and sixty-seven abdominal CT scan reports were examined along side their respective images on a GE Centricity workstation. Thirty-four (12.7%) were labeled as acute appendicitis cases based on the CT findings and the rest were assigned other diagnoses. Twenty-six of the 267 CT scan reports were plain studies and 241 were contrast-enhanced scans. Less than half of the patients (123, 46.1%) were males and 144 (53.9%) were females. Thirteen males (48.1%) and 14 (51.9%) females were found to have an appendicolith. Only 3% in the ≤ 11 years' age group, in contrast to 40% in the 11-20 years' age group, was diagnosed with appendicitis. The incidence in other age groups was as follows: 19% in the 21-30, 14% in the 31-40, 2.5% in the 41-50, 8% each in the 51-60 and 61-70, and none in the ≥71 years' age groups. Conclusions: We conclude that the presence of an appendicolith i) has no particular predilection for gender or age, and ii) is not associated with a diagnosis of appendicitis. PMID:19794272
Cistaro, A; Pazè, F; Durando, S; Cogoni, M; Faletti, R; Vesco, S; Vallero, S; Quartuccio, N; Treglia, G; Ramenghi, U
2014-01-01
A young patient with undefined autoimmune lymphoproliferative syndrome (ALPS-U) and low back pain underwent a CT and MRI study that showed enhancing vertebral lesions, some pulmonary nodules and diffuse latero-cervical lymphadenopathy. A (18)F-FDG-PET/CT scan showed many areas of intense (18)F-FDG uptake in multiple vertebrae, in some ribs, in the sacrum, in the liver, in both lungs, in multiple lymph nodes spread in the cervical, thoracic and abdominal chains. A bone marrow biopsy showed a "lymphomatoid granulomatosis", a rare variant of B-cell non-Hodgkin lymphoma (NHL). After the treatment, the (18)F-FDG-PET/CT scan showed a complete metabolic response. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.
McGrew, Patrick R; Chestovich, Paul J; Fisher, Jay D; Kuhls, Deborah A; Fraser, Douglas R; Patel, Purvi P; Katona, Chad W; Saquib, Syed; Fildes, John J
2018-05-04
Computed Tomography (CT) scans are useful in the evaluation of trauma patients, but are costly and pose risks from ionizing radiation in children. Recent literature has demonstrated the utility of CT scan guidelines in the management of pediatric trauma. This study objective is to review our treatment of pediatric blunt trauma patients and evaluate CT utilization before and after CT-guideline implementation. Our Pediatric Level 2 Trauma Center (TC) implemented a CT scan practice guideline for pediatric trauma patients in March 2014. The guideline recommended for or against CT of the head and abdomen/pelvis utilizing published criteria from the Pediatric Emergency Care and Research Network (PECARN). There was no chest CT guideline. We reviewed all pediatric trauma patients for CT scans obtained during initial evaluation before and after guideline implementation, excluding inpatient scans. The Trauma Registry Database was queried to include all pediatric (age<15) trauma patients seen in our TC from 2010-2016, excluding penetrating mechanism and deaths in the TC. Scans were considered positive if organ injury was detected. Primary outcome was the proportion of patients undergoing CT and percent positive CTs. Secondary outcomes were hospital length of stay (LOS), readmissions, and mortality. Categorical and continuous variables were analyzed with Chi-square and Wilcoxon rank-sum tests, respectively. P<0.05 was considered significant. We identified 1934 patients: 1106 pre- and 828 post-guideline. Absolute reductions in head, chest, and abdomen/pelvis CT scans were 17.7%, 11.5%, and 18.8% respectively (p<0.001). Percent positive head CTs were equivalent, but percent positive chest and abdomen CT increased after implementation. Secondary outcomes were unchanged. Implementation of a pediatric CT guideline significantly decreases CT utilization, reducing the radiation exposure without a difference in outcome. Trauma centers treating pediatric patients should adopt similar guidelines to decrease unnecessary CT scans in children. Level IV, Therapeutic Study.
Tan, Yan; Xiao, En-hua
2012-10-01
To evaluate the dynamic CT, MRI, ultrasonography, and pathologic features of hepatic perivascular epithelioid cell tumor (PEComa), improving the understanding and diagnosis of the tumor. A retrospective analysis of CT, MRI, ultrasonography, and pathologic features of 7 hepatic PEComas diagnosed by pathology during 1st January 2005 to 1st September 2011 in our hospital. The performance of dynamic CT, MRI, and ultrasonography revealed that lesions were regular masses with well-defined borders, the maximum diameters were 2.5-8.5 cm (mean = 4 cm), density was homogeneous, contrast-enhanced CT and MRI showed the lesions were significantly and heterogeneously enhanced on arterial phase, less enhanced on portal venous phase, and slightly hypodense on delayed phase. One patient had multiple hepatic lesions and had delayed enhancement. There were no backgrounds of hepatitis and cirrhosis, enlarged lymph nodes, or distant metastases. Pathology showed the gross appearance of the tumor was smooth. Tumor cells were round or polygonal, with clear boundaries and clear membranes, and had abundant translucent cytoplasm. Nuclei were round, with medium size. Tumor cells were epithelial-like cells and arranged in dense sheets. Immunohistochemistry showed that most of them were positive in HMB45 and MelanA, S-100, SMA, while negative in CgA, Syn, CK, CD117, CD10, and CD34. Dynamic CT, MRI, ultrasonography, and pathology of PEComa had some characteristics of benign tumor's performance. Enhanced scan showed PEComa quickly enhanced on arterial phase and enhanced less on portal venous phase. Knowing these characteristics could help to improve the understanding and diagnosis of hepatic PEComa.
Hanna, Gerard G; McAleese, Jonathan; Carson, Kathryn J; Stewart, David P; Cosgrove, Vivian P; Eakin, Ruth L; Zatari, Ashraf; Lynch, Tom; Jarritt, Peter H; Young, V A Linda; O'Sullivan, Joe M; Hounsell, Alan R
2010-05-01
Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV(CT) to GTV(FUSED) was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.
Is the routine CT head scan justified for psychiatric patients? A prospective study.
Ananth, J; Gamal, R; Miller, M; Wohl, M; Vandewater, S
1993-01-01
Thirty-four psychiatric patients, assessed for a physical illness that was missed during diagnosis, underwent a CT scan. After investigation, the diagnosis of 14 patients changed from a functional to an organic illness. In nine patients, the CT scan was reported to be abnormal, and yet only two were diagnosed as having an organic syndrome. In seven patients, the CT scan was normal but the patients had an undisputed organic brain syndrome. These findings indicate that the use of CT scans should be restricted to cases in which the diagnosis is seriously in question. The clinical findings should dictate the use of CT scans either to clarify or to complement them. PMID:8461285
Rowe, Steven P; Deville, Curtiland; Paller, Channing; Cho, Steve Y; Fishman, Elliot K; Pomper, Martin G; Ross, Ashley E; Gorin, Michael A
2015-12-01
Prostate-specific membrane antigen (PSMA)-targeted PET imaging is an emerging technique for evaluating patients with prostate cancer (PCa) in a variety of clinical contexts. As with any new imaging modality, there are interpretive pitfalls that are beginning to be recognized. In this image report, we describe the findings in a 63-year-old male with biochemically recurrent PCa after radical prostatectomy who was imaged with 18 F-DCFPyL, a small molecule inhibitor of PSMA. Diffuse radiotracer uptake was noted throughout the sacrum, corresponding to imaging findings on contrast-enhanced CT, bone scan, and pelvic MRI consistent with Paget's disease of bone. The uptake of 18 F-DCFPyL in Paget's disease is most likely due to hyperemia and increased radiotracer delivery. In light of the overlap in patients affected by PCa and Paget's, it is important for nuclear medicine physicians and radiologists interpreting PSMA PET/CT scans to be aware of the potential for this diagnostic pitfall. Correlation to findings on conventional imaging such as diagnostic CT and bone scan can help confirm the diagnosis.
CT scans for pulmonary surveillance may be overused in lower-grade sarcoma.
Miller, Benjamin J; Carmody Soni, Emily E; Reith, John D; Gibbs, C Parker; Scarborough, Mark T
2012-01-01
Chest CT scans are often used to monitor patients after excision of a sarcoma. Although sensitive, CT scans are more expensive than chest radiographs and are associated with possible health risks from a higher radiation dose. We hypothesized that a program based upon limited CT scans in lower-grade sarcoma could be efficacious and less expensive. We retrospectively assigned patients to a high-risk or low-risk hypothetical protocol. Eighty-three low- or intermediate-grade soft tissue sarcomas met our inclusion criteria. Eight patients had pulmonary metastasis. A protocol based on selective CT scans for high-risk patients would have identified seven out of eight lesions. The incremental cost-effectiveness ratio for routine CT scans was $731,400. A program based upon selective CT scans for higher-risk patients is accurate, spares unnecessary radiation to many patients, and is less expensive.
... and intestine using x-rays or computed tomography (CAT scan, CT scan; a type of body scan that uses a ... be clearly seen by x-ray examination or CT scan. ... more times before an x-ray examination or CT scan.If you are using a barium sulfate enema, ...
Näsvall, P; Wikner, F; Gunnarsson, U; Rutegård, J; Strigård, K
2014-10-01
Since there are no reliable investigative tools for imaging parastomal hernia, new techniques are needed. The aim of this study was to assess the validity of intrastomal three-dimensional ultrasonography (3D) as an alternative to CT scanning for the assessment of stomal complaints. Twenty patients with stomal complaints, indicating surgery, were examined preoperatively with a CT scan in the supine position and 3D intrastomal ultrasonography in the supine and erect positions. Comparison with findings at surgery, considered to be the true state, was made. Both imaging methods, 3D ultrasonography and CT scanning, showed high sensitivity (ultrasound 15/18, CT scan 15/18) and specificity (ultrasound 2/2, CT scan 1/2) when judged by a dedicated radiologist. Corresponding values for interpretation of CT scans in routine clinical practice was for sensitivity 17/18 and for specificity 1/2. 3D ultrasonography has a high validity and is a promising alternative to CT scanning in the supine position to distinguish a bulge from a parastomal hernia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Weili; Kim, Joshua P.; Kadbi, Mo
2015-11-01
Purpose: To incorporate a novel imaging sequence for robust air and tissue segmentation using ultrashort echo time (UTE) phase images and to implement an innovative synthetic CT (synCT) solution as a first step toward MR-only radiation therapy treatment planning for brain cancer. Methods and Materials: Ten brain cancer patients were scanned with a UTE/Dixon sequence and other clinical sequences on a 1.0 T open magnet with simulation capabilities. Bone-enhanced images were generated from a weighted combination of water/fat maps derived from Dixon images and inverted UTE images. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessedmore » by calculating segmentation errors (true-positive rate, false-positive rate, and Dice similarity indices using CT simulation (CT-SIM) as ground truth. The synCTs were generated using a voxel-based, weighted summation method incorporating T2, fluid attenuated inversion recovery (FLAIR), UTE1, and bone-enhanced images. Mean absolute error (MAE) characterized Hounsfield unit (HU) differences between synCT and CT-SIM. A dosimetry study was conducted, and differences were quantified using γ-analysis and dose-volume histogram analysis. Results: On average, true-positive rate and false-positive rate for the CT and MR-derived air masks were 80.8% ± 5.5% and 25.7% ± 6.9%, respectively. Dice similarity indices values were 0.78 ± 0.04 (range, 0.70-0.83). Full field of view MAE between synCT and CT-SIM was 147.5 ± 8.3 HU (range, 138.3-166.2 HU), with the largest errors occurring at bone–air interfaces (MAE 422.5 ± 33.4 HU for bone and 294.53 ± 90.56 HU for air). Gamma analysis revealed pass rates of 99.4% ± 0.04%, with acceptable treatment plan quality for the cohort. Conclusions: A hybrid MRI phase/magnitude UTE image processing technique was introduced that significantly improved bone and air contrast in MRI. Segmented air masks and bone-enhanced images were integrated into our synCT pipeline for brain, and results agreed well with clinical CTs, thereby supporting MR-only radiation therapy treatment planning in the brain.« less
Zheng, Weili; Kim, Joshua P; Kadbi, Mo; Movsas, Benjamin; Chetty, Indrin J; Glide-Hurst, Carri K
2015-11-01
To incorporate a novel imaging sequence for robust air and tissue segmentation using ultrashort echo time (UTE) phase images and to implement an innovative synthetic CT (synCT) solution as a first step toward MR-only radiation therapy treatment planning for brain cancer. Ten brain cancer patients were scanned with a UTE/Dixon sequence and other clinical sequences on a 1.0 T open magnet with simulation capabilities. Bone-enhanced images were generated from a weighted combination of water/fat maps derived from Dixon images and inverted UTE images. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating segmentation errors (true-positive rate, false-positive rate, and Dice similarity indices using CT simulation (CT-SIM) as ground truth. The synCTs were generated using a voxel-based, weighted summation method incorporating T2, fluid attenuated inversion recovery (FLAIR), UTE1, and bone-enhanced images. Mean absolute error (MAE) characterized Hounsfield unit (HU) differences between synCT and CT-SIM. A dosimetry study was conducted, and differences were quantified using γ-analysis and dose-volume histogram analysis. On average, true-positive rate and false-positive rate for the CT and MR-derived air masks were 80.8% ± 5.5% and 25.7% ± 6.9%, respectively. Dice similarity indices values were 0.78 ± 0.04 (range, 0.70-0.83). Full field of view MAE between synCT and CT-SIM was 147.5 ± 8.3 HU (range, 138.3-166.2 HU), with the largest errors occurring at bone-air interfaces (MAE 422.5 ± 33.4 HU for bone and 294.53 ± 90.56 HU for air). Gamma analysis revealed pass rates of 99.4% ± 0.04%, with acceptable treatment plan quality for the cohort. A hybrid MRI phase/magnitude UTE image processing technique was introduced that significantly improved bone and air contrast in MRI. Segmented air masks and bone-enhanced images were integrated into our synCT pipeline for brain, and results agreed well with clinical CTs, thereby supporting MR-only radiation therapy treatment planning in the brain. Copyright © 2015 Elsevier Inc. All rights reserved.
Kornmann, Verena N N; Treskes, Nikki; Hoonhout, Lilian H F; Bollen, Thomas L; van Ramshorst, Bert; Boerma, Djamila
2013-04-01
Timely diagnosis of anastomotic leakage after colorectal surgery and adequate treatment is important to reduce morbidity and mortality. Abdominal computed tomography (CT) scanning is the diagnostic tool of preference, but its value may be questionable in the early postoperative period. The accuracy of CT scanning for the detection of anastomotic leakage and its role in timing of intervention was evaluated. A systematic literature search was performed. Relevant publications were identified from four electronic databases between 1990 and 2011. Inclusion criteria were human studies, studies published in English or Dutch, colorectal surgery with primary anastomosis, and abdominal CT scan with reported outcome for the detection of anastomotic leakage. Exclusion criteria were cohort of fewer than five patients, other gastrointestinal surgery, no anastomosis, and radiological imaging other than CT. Eight studies, including 221 abdominal CT scans, fulfilled the inclusion criteria. Overall, the methodological quality of the studies was poor. The overall sensitivity of CT scanning to diagnose leakage was 0.68 (95 % confidence interval 0.59-0.75) for colonic resection. Data on the sequelae of false-negative CT scanning was not available. There is limited good-quality evidence to determine the value of CT scans in the detection of anastomotic leakage. To prevent delay in diagnosis and appropriate treatment of anastomotic leakage, the relatively low sensitivity of CT scanning must be taken into account.
Effect of staff training on radiation dose in pediatric CT.
Hojreh, Azadeh; Weber, Michael; Homolka, Peter
2015-08-01
To evaluate the efficacy of staff training on radiation doses applied in pediatric CT scans. Pediatric patient doses from five CT scanners before (1426 scans) and after staff training (2566 scans) were compared statistically. Examinations included cranial CT (CCT), thoracic, abdomen-pelvis, and trunk scans. Dose length products (DLPs) per series were extracted from CT dose reports archived in the PACS. A pooled analysis of non-traumatic scans revealed a statistically significant reduction in the dose for cranial, thoracic, and abdomen/pelvis scans (p<0.01). This trend could be demonstrated also for trunk scans, however, significance could not be established due to low patient frequencies (p>0.05). The percentage of scans performed with DLPs exceeding the German DRLs was reduced from 41% to 7% (CCT), 19% to 5% (thorax-CT), from 9% to zero (abdominal-pelvis CT), and 26% to zero (trunk; DRL taken as summed DRLs for thorax plus abdomen-pelvis, reduced by 20% accounting for overlap). Comparison with Austrian DRLs - available only for CCT and thorax CT - showed a reduction from 21% to 3% (CCT), and 15 to 2% (thorax CT). Staff training together with application of DRLs provide an efficient approach for optimizing radiation dose in pediatric CT practice. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Thurley, Pete; Crookdake, Jonathan; Norwood, Mark; Sturrock, Nigel; Fogarty, Andrew W
2018-02-01
Avoiding unnecessary radiation exposure is a clinical priority in children and young adults. We aimed to explore demand for CT scans in a busy general hospital with particular interest in the period of transition from paediatric to adult medical care. We used an observational epidemiological study based in a teaching hospital. Data were obtained on numbers and rates of CT scans from 2009 to 2015. The main outcome was age-stratified rates of receiving a CT scan. There were a total of 262,221 CT scans. There was a large step change in the rate of CT scans over the period of transition from paediatric to adult medical care. Individuals aged 10-15 years experienced 6.7 CT scans per 1000 clinical episodes, while those aged 19-24 years experienced 19.8 CT scans per 1000 clinical episodes (p < 0.001). This difference remained significant for all sensitivity analyses. There is almost a threefold increase in rates of CT scans in the two populations before and after the period of transition from paediatric to adult medical care. While we were unable to adjust for case mix or quantify radiation exposure, paediatricians' diagnostic strategies to minimize radiation exposure may have clinical relevance for adult physicians, and hence enable reductions in ionizing radiation to patients. Advances in knowledge: A large increase in rates of CT scans occurs during adolescence, and considering paediatricians' strategies to minimize radiation exposure may enable reductions to all patients.
Xue, Hua-dan; Liu, Wei; Sun, Hao; Wang, Xuan; Chen, Yu; Su, Bai-yan; Sun, Zhao-yong; Chen, Fang; Jin, Zheng-yu
2010-12-01
To analyze the clinical value of multiple sequences derived from dual-source computed tomography (DSCT) dual-energy scan mode in detecting pancreatic adenocarcinoma. Totally 23 patients with clinically or pathologically diagnosed pancreatic cancer were enrolled in this retrospective study. DSCT (Definition Flash) was used and dual-energy scan mode was used in their pancreatic parenchyma phase scan (100kVp/230mAs and Sn140kVp/178mAs) . Mono-energetic 60kev, mono-energetic 80kev, mono-energetic 100kev, mono-energetic 120kev, linear blend image, non-linear blend image, and iodine map were acquired. pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were calculated. One-way ANOVA was used for the comparison of diagnostic values of the above eight different dual-energy derived sequences for pancreatic cancer. The pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were significantly different among eight sequences (P<0.05) . Mono-energetic 60kev image showed the largest parenchyma-tumor CT value [ (77.53 ± 23.42) HU] , and iodine map showed the lowest tumor/parenchyma enhancement ratio (0.39?0.12) and the largest contrast to noise ratio (4.08 ± 1.46) . Multiple sequences can be derived from dual-energy scan mode with DSCT via multiple post-processing methods. Integration of these sequences may further improve the sensitivity of the multislice spiral CT in the diagnosis of pancreatic cancer.
Gated CT imaging using a free-breathing respiration signal from flow-volume spirometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Souza, Warren D.; Kwok, Young; Deyoung, Chad
2005-12-15
Respiration-induced tumor motion is known to cause artifacts on free-breathing spiral CT images used in treatment planning. This leads to inaccurate delineation of target volumes on planning CT images. Flow-volume spirometry has been used previously for breath-holds during CT scans and radiation treatments using the active breathing control (ABC) system. We have developed a prototype by extending the flow-volume spirometer device to obtain gated CT scans using a PQ 5000 single-slice CT scanner. To test our prototype, we designed motion phantoms to compare image quality obtained with and without gated CT scan acquisition. Spiral and axial (nongated and gated) CTmore » scans were obtained of phantoms with motion periods of 3-5 s and amplitudes of 0.5-2 cm. Errors observed in the volume estimate of these structures were as much as 30% with moving phantoms during CT simulation. Application of motion-gated CT with active breathing control reduced these errors to within 5%. Motion-gated CT was then implemented in patients and the results are presented for two clinical cases: lung and abdomen. In each case, gated scans were acquired at end-inhalation, end-exhalation in addition to a conventional free-breathing (nongated) scan. The gated CT scans revealed reduced artifacts compared with the conventional free-breathing scan. Differences of up to 20% in the volume of the structures were observed between gated and free-breathing scans. A comparison of the overlap of structures between the gated and free-breathing scans revealed misalignment of the structures. These results demonstrate the ability of flow-volume spirometry to reduce errors in target volumes via gating during CT imaging.« less
Shim, Eun Jung; Ahn, Sung Eun; Lee, Dong Ho; Park, Seong Jin; Kim, Youn Wha
2017-01-01
Inflammatory fibroid polyp (IFP) is a rare benign lesion of the gastrointestinal tract. We report a case of computed tomography (CT) imaging finding of a gastric IFP with massive fibrosis. CT scans showed thickening of submucosal layer with overlying mucosal hyperenhancement in the gastric antrum. The submucosal layer showed increased enhancement on delayed phase imaging. An antrectomy with gastroduodenostomy was performed because gastric cancer was suspected, particularly signet ring cell carcinoma. The histopathological diagnosis was an IFP with massive fibrosis. The authors suggest that when the submucosal layer of the gastric wall is markedly thickened with delayed enhancement and preservation of the mucosal layer, an IFP with massive fibrosis should be considered in the differential diagnosis. PMID:28373777
Triphasic contrast enhanced CT simulation with bolus tracking for pancreas SBRT target delineation.
Godfrey, Devon J; Patel, Bhavik N; Adamson, Justus D; Subashi, Ergys; Salama, Joseph K; Palta, Manisha
Bolus-tracked multiphasic contrast computed tomography (CT) is often used in diagnostic radiology to enhance the visibility of pancreas tumors, but is uncommon in radiation therapy pancreas CT simulation, and its impact on gross tumor volume (GTV) delineation is unknown. This study evaluates the lesion conspicuity and consistency of pancreas stereotactic body radiation therapy (SBRT) GTVs contoured in the different contrast phases of triphasic CT simulation scans. Triphasic, bolus-tracked planning CT simulation scans of 10 consecutive pancreas SBRT patients were acquired, yielding images of the pancreas during the late arterial (LA), portal venous (PV), and either the early arterial or delayed phase. GTVs were contoured on each phase by a gastrointestinal-specialized radiation oncologist and reviewed by a fellowship-trained abdominal radiologist who specializes in pancreatic imaging. The volumes of the registered GTVs, their overlap ratio, and the 3-dimensional margin expansions necessary for each GTV to fully encompass GTVs from the other phases were calculated. The contrast difference between tumor and normal pancreas was measured, and 2 radiation oncologists rank-ordered the phases according to their value for the lesion-contouring task. Tumor-to-pancreas enhancement was on average much larger for the LA and PV than the delayed phase or early arterial phases; the LA and PV phases were also consistently preferred by the radiation oncologists. Enhancement differences among the phases resulted in highly variable GTV volumes with no observed trends. Overlap ratios ranged from 18% to 75% across all 3 phases, improving to 43% to 91% when considering only the preferred LA and PV phases. GTV expansions necessary to encompass all GTVs ranged from 0.3 to 1.8 cm for all 3 phases, improving slightly to 0.1 to 1.4 cm when considering just the LA and PV phases. For pancreas SBRT, we recommend combining the GTVs from a multiphasic CT simulation with bolus-tracking, including, at a minimum, a Boolean "OR" of the LA and PV phases. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
New prospective 4D-CT for mitigating the effects of irregular respiratory motion
NASA Astrophysics Data System (ADS)
Pan, Tinsu; Martin, Rachael M.; Luo, Dershan
2017-08-01
Artifact caused by irregular respiration is a major source of error in 4D-CT imaging. We propose a new prospective 4D-CT to mitigate this source of error without new hardware, software or off-line data-processing on the GE CT scanner. We utilize the cine CT scan in the design of the new prospective 4D-CT. The cine CT scan at each position can be stopped by the operator when an irregular respiration occurs, and resumed when the respiration becomes regular. This process can be repeated at one or multiple scan positions. After the scan, a retrospective reconstruction is initiated on the CT console to reconstruct only the images corresponding to the regular respiratory cycles. The end result is a 4D-CT free of irregular respiration. To prove feasibility, we conducted a phantom and six patient studies. The artifacts associated with the irregular respiratory cycles could be removed from both the phantom and patient studies. A new prospective 4D-CT scanning and processing technique to mitigate the impact of irregular respiration in 4D-CT has been demonstrated. This technique can save radiation dose because the repeat scans are only at the scan positions where an irregular respiration occurs. Current practice is to repeat the scans at all positions. There is no cost to apply this technique because it is applicable on the GE CT scanner without new hardware, software or off-line data-processing.
McAllister, E; Perez, M; Albrink, M H; Olsen, S M; Rosemurgy, A S
1994-09-01
We devised a protocol to prospectively manage stab wounds to the back with the hypothesis that the triple contrast computed tomographic (CT) scan is an effective means of detecting occult injury in these patients. All wounds to the back in hemodynamically stable adults were locally explored. All patients with muscular fascial penetration underwent triple contrast CT scanning utilizing oral, rectal, and IV contrast. Patients did not undergo surgical exploration if their CT scan was interpreted as negative or if the CT scan demonstrated injuries not requiring surgical intervention. Fifty-three patients were entered into the protocol. The time to complete the triple contrast CT scan ranged from 3 to 6 hours at a cost of $1050 for each scan. In 51 patients (96%), the CT scan either had negative findings (n = 31) or showed injuries not requiring exploration (n = 20). These patients did well with nonsurgical management. Two CT scans documented significant injury and led to surgical exploration and therapeutic celiotomies. Although triple contrast CT scanning was able to detect occult injury in patients with stab wounds to the back it did so at considerable cost and the results rarely altered clinical care. Therefore, its routine use in these patients is not recommended.
Optimising μCT imaging of the middle and inner cat ear.
Seifert, H; Röher, U; Staszyk, C; Angrisani, N; Dziuba, D; Meyer-Lindenberg, A
2012-04-01
This study's aim was to determine the optimal scan parameters for imaging the middle and inner ear of the cat with micro-computertomography (μCT). Besides, the study set out to assess whether adequate image quality can be obtained to use μCT in diagnostics and research on cat ears. For optimisation, μCT imaging of two cat skull preparations was performed using 36 different scanning protocols. The μCT-scans were evaluated by four experienced experts with regard to the image quality and detail detectability. By compiling a ranking of the results, the best possible scan parameters could be determined. From a third cat's skull, a μCT-scan, using these optimised scan parameters, and a comparative clinical CT-scan were acquired. Afterwards, histological specimens of the ears were produced which were compared to the μCT-images. The comparison shows that the osseous structures are depicted in detail. Although soft tissues cannot be differentiated, the osseous structures serve as valuable spatial orientation of relevant nerves and muscles. Clinical CT can depict many anatomical structures which can also be seen on μCT-images, but these appear a lot less sharp and also less detailed than with μCT. © 2011 Blackwell Verlag GmbH.
Radiation exposure from Chest CT: Issues and Strategies
Maher, Michael M.; Rizzo, Stefania; Kanarek, David; Shephard, Jo-Anne O.
2004-01-01
Concerns have been raised over alleged overuse of CT scanning and inappropriate selection of scanning methods, all of which expose patients to unnecessary radiation. Thus, it is important to identify clinical situations in which techniques with lower radiation dose such as plain radiography or no radiation such as MRI and occasionally ultrasonography can be chosen over CT scanning. This article proposes the arguments for radiation dose reduction in CT scanning of the chest and discusses recommended practices and studies that address means of reducing radiation exposure associated with CT scanning of the chest. PMID:15082885
Kinner, Sonja; Pickhardt, Perry J; Riedesel, Erica L; Gill, Kara G; Robbins, Jessica B; Kitchin, Douglas R; Ziemlewicz, Timothy J; Harringa, John B; Reeder, Scott B; Repplinger, Michael D
2017-10-01
Appendicitis is frequently diagnosed in the emergency department, most commonly using CT. The purpose of this study was to compare the diagnostic accuracy of contrast-enhanced MRI with that of contrast-enhanced CT for the diagnosis of appendicitis in adolescents when interpreted by abdominal radiologists and pediatric radiologists. Our study included a prospectively enrolled cohort of 48 patients (12-20 years old) with nontraumatic abdominal pain who underwent CT and MRI. Fellowship-trained abdominal and pediatric radiologists reviewed all CT and MRI studies in randomized order, blinded to patient outcome. Likelihood for appendicitis was rated on a 5-point scale (1, definitely not appendicitis; 5, definitely appendicitis) for CT, the unenhanced portion of the MRI, and the entire contrast-enhanced MRI study. ROC curves were generated and AUC compared for each scan type for all six readers and then stratified by radiologist type. Image test characteristics, interrater reliability, and reading times were compared. Sensitivity and specificity were 85.9% (95% CI, 76.2-92.7%) and 93.8% (95% CI, 89.7-96.7%) for unenhanced MRI, 93.6% (95% CI, 85.6-97.9%) and 94.3% (95% CI, 90.2-97%) for contrast-enhanced MRI, and 93.6% (95% CI, 85.6-97.9%) and 94.3% (95% CI, 90.2-97%) for CT. No difference was found in the diagnostic accuracy or interpretation time when comparing abdominal radiologists to pediatric radiologists (CT, 3.0 min vs 2.8 min; contrast-enhanced MRI, 2.4 min vs 1.8 min; unenhanced MRI, 1.5 min vs 2.3 min). Substantial agreement between abdominal and pediatric radiologists was seen for all methods (κ = 0.72-0.83). The diagnostic accuracy of MRI to diagnose appendicitis was very similar to CT. No statistically significant difference in accuracy was observed between imaging modality or radiologist subspecialty.
DOE Office of Scientific and Technical Information (OSTI.GOV)
So, Aaron, E-mail: aso@robarts.ca
Purpose: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Methods: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisitionmore » protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated from the dynamic contrast-enhanced (DCE) heart images taken at baseline and three weeks after the ischemic insult. Results: Their results showed that the phantom and animal images acquired with the CT platform were minimally affected by image noise and artifacts. For the beam-hardening phantom study, changes in water HU in the wall surrounding the heart chambers greatly reduced from >±30 to ≤ ± 5 HU at all kVp settings except one region at 100 kVp (7 HU). For the cone-beam phantom study, differences in mean water HU from the central slice were less than 5 HU at two peripheral slices with each 4 cm away from the central slice. These findings were reproducible in the pig DCE images at two peripheral slices that were 6 cm away from the central slice. For the partial-scan phantom study, standard deviations of the mean water HU in 10 successive partial scans were less than 5 HU at the central slice. Similar observations were made in the pig DCE images at two peripheral slices with each 6 cm away from the central slice. For the image noise phantom study, CNRs in the ASiR-V images were statistically higher (p < 0.05) than the non-ASiR-V images at all kVp settings. MP maps generated from the porcine DCE images were in excellent quality, with the ischemia in the LAD territory clearly seen in the three orthogonal views. Conclusions: The study demonstrates that this CT system can provide accurate and reproducible CT numbers during cardiac gated acquisitions across a wide axial field of view. This CT number fidelity will enable this imaging tool to assess contrast enhancement, potentially providing valuable added information beyond anatomic evaluation of coronary stenoses. Furthermore, their results collectively suggested that the 100 kVp/25 mAs protocol run on this CT system provides sufficient image accuracy at a low radiation dose (<3 mSv) for whole-heart quantitative CT MP imaging.« less
Konda, Sanjit R; Davidovitch, Roy I; Egol, Kenneth A
2013-09-01
To report our experience with computed tomography (CT) scans to detect traumatic arthrotomies of the knee (TAK) joint based on the presence of intra-articular air. Retrospective review. Level I trauma center. Sixty-two consecutive patients (63 knees) underwent a CT scan of the knee in the emergency department and had a minimum of 14 days follow-up. Cohort of 37 patients (37 knees) from the original 62 patients who underwent a saline load test (SLT). CT scan and SLT. Positive traumatic arthrotomy of the knee (+TAK) was defined as operating room (OR) confirmation of an arthrotomy or no intra-articular air on CT scan (-iaCT) (and -SLT if performed) with follow-up revealing a septic knee. Periarticular wound equivalent to no traumatic arthrotomy (pw = (-TAK)) was defined as OR evaluation revealing no arthrotomy or -iaCT (and -SLT if performed) with follow-up revealing no septic knee. All 32 knees with intra-articular air on CT scan (+iaCT) had OR confirmation of a TAK and none of these patients had a knee infection at a mean follow-up of 140.0 ± 279.6 days. None of the 31 patients with -iaCT had a knee infection at a mean follow-up of 291.0 ± 548.1 days. Based on these results, the sensitivity and specificity of the CT scan to detect +TAK and pw = (-TAK) was 100%. In a subgroup of 37 patients that received both a CT scan and the conventional SLT, the sensitivity and specificity of the CT scan was 100% compared with 92% for the SLT (P < 0.001). CT scan performs better than the conventional SLT to detect traumatic knee arthrotomies and identify periarticular knee wounds that do not require surgical intervention and should be considered a valid diagnostic test in the appropriate clinical setting. Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Black Hole Sign Predicts Poor Outcome in Patients with Intracerebral Hemorrhage.
Li, Qi; Yang, Wen-Song; Chen, Sheng-Li; Lv, Fu-Rong; Lv, Fa-Jin; Hu, Xi; Zhu, Dan; Cao, Du; Wang, Xing-Chen; Li, Rui; Yuan, Liang; Qin, Xin-Yue; Xie, Peng
2018-01-01
In spontaneous intracerebral hemorrhage (ICH), black hole sign has been proposed as a promising imaging marker that predicts hematoma expansion in patients with ICH. The aim of our study was to investigate whether admission CT black hole sign predicts hematoma growth in patients with ICH. From July 2011 till February 2016, patients with spontaneous ICH who underwent baseline CT scan within 6 h of symptoms onset and follow-up CT scan were recruited into the study. The presence of black hole sign on admission non-enhanced CT was independently assessed by 2 readers. The functional outcome was assessed using the modified Rankin Scale (mRS) at 90 days. Univariate and multivariable logistic regression analyses were performed to assess the association between the presence of the black hole sign and functional outcome. A total of 225 patients (67.6% male, mean age 60.3 years) were included in our study. Black hole sign was identified in 32 of 225 (14.2%) patients on admission CT scan. The multivariate logistic regression analysis demonstrated that age, intraventricular hemorrhage, baseline ICH volume, admission Glasgow Coma Scale score, and presence of black hole sign on baseline CT independently predict poor functional outcome at 90 days. There are significantly more patients with a poor functional outcome (defined as mRS ≥4) among patients with black hole sign than those without (84.4 vs. 32.1%, p < 0.001; OR 8.19, p = 0.001). The CT black hole sign independently predicts poor outcome in patients with ICH. Early identification of black hole sign is useful in prognostic stratification and may serve as a potential therapeutic target for anti-expansion clinical trials. © 2018 S. Karger AG, Basel.
Yamashiro, Tsuneo; Miyara, Tetsuhiro; Honda, Osamu; Kamiya, Ayano; Tanaka, Yuko; Murayama, Sadayuki
2014-01-01
The aim of this study was to compare density heterogeneity on wide volume (WV) scans with that on helical CT scans. 22 subjects underwent chest CT using 320-WV and 64-helical modes. Density heterogeneity of the descending aorta was evaluated quantitatively and qualitatively. At qualitative assessment, the heterogeneity was judged to be smaller on WV scans than on helical scans (p<0.0001). Mean changes in aortic density between two contiguous slices were 1.64 HU (3.40%) on WV scans and 2.29 HU (5.19%) on helical scans (p<0.0001). CT density of thoracic organs is more homogeneous and reliable on WV scans than on helical scans. Copyright © 2013 Elsevier Ltd. All rights reserved.
Todd, A W; Anderson, E M
2009-05-01
National audit data allow crude comparison between centres and indicate that most Scottish hospitals fail to meet current guidelines for CT scanning of the brain in stroke patients. This study identifies some of the reasons for delay in performing CT scans in a largely rural population. This audit study assesses the delays from onset of symptoms, time of admission and request received to CT scan in stroke patients for three different in-patient groups as well as those managed in the community. The reasons for delay in CT scanning varied between different patient groups but for one group of in-patients, changes in booking procedure and introduction of a second CT scanner increased the proportion scanned within 48 hours of request from 65% to 96%. Further developments including the introduction of Saturday and Sunday routine CT scanning, radiologist reporting from home and additional CT scanners placed in remote hospitals may be expected to improve these figures further. Target times of three hours from onset of symptoms to scan to allow thrombolysis may however be impossible to meet for all stroke patients in rural areas.
Bosch de Basea, Magda; Salotti, Jane A; Pearce, Mark S; Muchart, Jordi; Riera, Luis; Barber, Ignasi; Pedraza, Salvador; Pardina, Marina; Capdevila, Antoni; Espinosa, Ana; Cardis, Elisabeth
2016-01-01
Although there are undeniable diagnostic benefits of CT scanning, its increasing use in paediatric radiology has become a topic of concern regarding patient radioprotection. To assess the rate of CT scanning in Catalonia, Spain, among patients younger than 21 years old at the scan time. This is a sub-study of a larger international cohort study (EPI-CT, the International pediatric CT scan study). Data were retrieved from the radiological information systems (RIS) of eight hospitals in Catalonia since the implementation of digital registration (between 1991 and 2010) until 2013. The absolute number of CT scans annually increased 4.5% between 1991 and 2013, which was less accentuated when RIS was implemented in most hospitals. Because the population attending the hospitals also increased, however, the rate of scanned patients changed little (8.3 to 9.4 per 1,000 population). The proportions of patients with more than one CT and more than three CTs showed a 1.51- and 2.7-fold increase, respectively, over the 23 years. Gradual increases in numbers of examinations and scanned patients were observed in Catalonia, potentially explained by new CT scanning indications and increases in the availability of scanners, the number of scans per patient and the size of the attended population.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fried, D; Zhang, L; Fave, X
Purpose: Determine the impact of morphologic characteristics (e.g. necrosis, vascular enhancement, and cavitation) on radiomic features from contrast enhanced CT (CE-CT) in primary lung tumors. Methods: We developed an auto-segmentation algorithm to separate lung tumors on contrast-enhanced CT into cavitation (air), necrosis, tissue, and enhancing vessels using a combination of thresholding and region-growing. An auto-segmentation algorithm was also designed to identify necrosis on FDG-PET scans. Wilcoxon rank-sum tests were used to determine if significant differences existed in radiomics features (histogram-uniformity and Laplacian-of-Gaussian average) from 249 patients, found to prognostic in previous work, based on the presence/absence of morphologic features. Featuremore » values were also compared between the original tumor contours and contours excluding a specific morphologic feature. Comparison of necrosis segmentation on CE-CT versus FDG-PET was performed in 78 patients to assess for agreement using the concordance correlation coefficient (CCC). Results: Tumors with cavitation and enhancing vasculature had lower uniformity values (p = 0.001 and p = 0.03, respectively). Tumors with enhancing vasculature and necrosis had higher Laplacian-of-Gaussian average values (measure of “edges” within the tumor) (p < 0.001). Removing these tissue types from regions-of-interest did not drastically alter either radiomic feature value (all scenarios had R{sup 2} > 0.8). This suggests there may be interactions between morphologic characteristics and the radiomic feature value of tumor tissue. Comparison of necrosis volume and percent necrosis volume of tumor were found to have CCC values of 0.85 and 0.76, respectively between CE-CT and FDG-PET segmentation methods. Conclusions: Tumors with enhancing vasculature, necrosis, and cavitation have higher radiomic feature values that are associated with poor prognosis than tumors without these features. Removing these tissue types from quantitative assessment did not drastically impact radiomic feature values. High reproducibility of CE-CT segmented necrosis compared to FDG-PET segmented necrosis provides a reasonable validation of segmentation accuracy on CE-CT.« less
... this page: //medlineplus.gov/ency/article/003330.htm CT scan To use the sharing features on this page, please enable JavaScript. A computed tomography (CT) scan is an imaging method that uses x- ...
Computed Tomography (CT) - Spine
... Resources Professions Site Index A-Z Computed Tomography (CT) - Spine Computed tomography (CT) of the spine is ... of CT Scanning of the Spine? What is CT Scanning of the Spine? Computed tomography, more commonly ...
Scope for energy improvement for hospital imaging services in the USA.
Esmaeili, Amin; Twomey, Janet M; Overcash, Michael R; Soltani, Seyed A; McGuire, Charles; Ali, Kamran
2015-04-01
To aid radiologists by measuring the carbon footprint of CT scans by quantifying in-hospital and out-of-hospital energy use and to assess public health impacts. The study followed a standard life cycle assessment protocol to measure energy from a CT scan then expanding to all hospital electrical energy related to CT usage. In addition, all the fuel energy used to generate electricity and to manufacture the CT consumables was measured. The study was conducted at two hospitals. The entire life cycle energy for a CT scan was 24-34 kWh of natural resource energy per scan. The actual active patient scan energy that produces the images is only about 1.6% of this total life cycle energy. This large multiplier to get total CT energy is a previously undocumented environmental response to the direct radiology order for a patient CT scan. The CT in-hospital energy related to idle periods, where the machine is on but no patients are being scanned and is 14-30-fold higher than the energy used for the CT image. The in-hospital electrical energy of a CT scan makes up only about 25% of the total energy footprint. The rest is generated outside the hospital: 54-62% for generation and transmission of the electricity, while 13-22% is for all the energy to make the consumables. Different CT scanners have some influences on the results and could help guide purchase of CT equipment. The transparent, detailed life cycle approach allows the data from this study to be used by radiologists to examine details of both direct and of unseen energy impacts of CT scans. The public health (outside-the-hospital) impact (including the patients receiving a CT) needs to be measured and included. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
... Computed tomography scan - heart; Calcium scoring; Multi-detector CT scan - heart; Electron beam computed tomography - heart; Agatston ... table that slides into the center of the CT scanner. You will lie on your back with ...
Fischer, Georg; Liu, Cong; Audisio, Tracy L.; Alpert, Gary D.; Fisher, Brian L.; Economo, Evan P.
2017-01-01
We explore the potential of x-ray micro computed tomography (μCT) for the field of ant taxonomy by using it to enhance the descriptions of two remarkable new species of the ant genus Terataner: T. balrog sp. n. and T. nymeria sp. n.. We provide an illustrated worker-based species identification key for all species found on Madagascar, as well as detailed taxonomic descriptions, which include diagnoses, discussions, measurements, natural history data, high-quality montage images and distribution maps for both new species. In addition to conventional morphological examination, we have used virtual reconstructions based on volumetric μCT scanning data for the species descriptions. We also include 3D PDFs, still images of virtual reconstructions, and 3D rotation videos for both holotype workers and one paratype queen. The complete μCT datasets have been made available online (Dryad, https://datadryad.org) and represent the first cybertypes in ants (and insects). We discuss the potential of μCT scanning and critically assess the usefulness of cybertypes for ant taxonomy. PMID:28328931
The Caudate Lobe: The Blind Spot in Radioembolization or an Overlooked Opportunity?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braat, Manon N. G. J. A., E-mail: M.N.G.Braat-3@umcutrecht.nl; Hoven, Andor F. van den, E-mail: a.f.vandenhoven@umcutrecht.nl; Doormaal, Pieter J. van, E-mail: P.J.vanDoormaal-4@umcutrecht.nl
2016-06-15
PurposeThe caudate lobe (CL) is impartial to the functional left and right hemi-liver and has outspoken inter-individual differences in arterial vascularization. Unfortunately, this complexity is not specifically taken into account during radioembolization treatment (RE), potentially resulting in under- or overtreatment of the CL. The objective of this study was to evaluate the CL coverage in RE and determine the detection rate of the CL arteries on CT angiography during work-up.MethodsIn all consecutive patients who underwent RE treatment between May 2012–January 2015, {sup 99m}Tc-MAA SPECT/CT and posttreatment scans ({sup 90}Y-bremsstrahlung SPECT/CT, {sup 90}Y-PET/CT, or {sup 166}Ho-SPECT/CT) were reviewed for activity inmore » the CL. Pretreatment CT angiographies were reviewed for the visibility of the CL arteries.ResultsEighty-two patients were treated. In 32/82 (39 %) the CL was involved. In 6/32 (19 %) patients, no activity was seen on the posttreatment scan in the CL, whereas in 40/50 (80 %) patients without CL tumor involvement, the CL was treated. {sup 99m}Tc-MAA SPECT/CT and final posttreatment scans were discordant in 16/78 (21 %). {sup 99m}Tc-MAA SPECT/CT had a positive and negative predictive value of 94 % and 46 %, respectively, for activity in the CL after RE. In untreated CLs, significant hypertrophy was observed with a median volume increase of 33 % (p = 0.02). CL arteries were seldom visible on the pretreatment CT; the identification rate was 12–17 %.ConclusionCurrently in RE treatments, targeting or sparing of the CL is highly erratic and independent of tumor involvement. Intentional treatment or bypassing of the CL seems worthwhile to either improve tumor coverage or enhance the functional liver remnant.« less
Lee, D W; Byeon, H K; Chung, H P; Choi, E C; Kim, S-H; Park, Y M
2013-07-01
The findings of intraparotid facial nerve schwannoma (FNS) using preoperative diagnostic tools, including ultrasonography (US)-guided fine needle aspiration biopsy, computed tomography (CT) scan, and magnetic resonance imaging (MRI), were analyzed to determine if there are any useful findings that might suggest the presence of a lesion. Treatment guidelines are suggested. The medical records of 15 patients who were diagnosed with an intraparotid FNS were retrospectively analyzed. US and CT scans provide clinicians with only limited information; gadolinium enhanced T1-weighted images from MRI provide more specific findings. Tumors could be removed successfully with surgical exploration, preserving facial nerve function at the same time. Gadolinium-enhanced T1-weighted MRI showed more characteristic findings for the diagnosis of intraparotid FNS. Intraparotid FNS without facial palsy can be diagnosed with MRI preoperatively, and surgical exploration is a suitable treatment modality which can remove the tumor and preserve facial nerve function. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Eze, K C; Mazeli, F O
2011-01-01
The outcome of head trauma as a result of road accident rests with increased use of CT scan and other radiological imaging modalities for prompt diagnosis is important. To find out the time of presentation for CT scan, symptoms for referral for CT scan and pattern of injuries in patients with cranial CT scan following road traffic accidents. Retrospective analysis of cranial computed tomography (CT) films, request cards, duplicate copy of radiology reports, soft copy CT images and case notes of 61 patients who underwent cranial CT scan on account of road traffic accidents. The study CT scans were performed at the radiology department of University Teaching Hospital between 1st January 2002 and 31st December 2004. 51 patients (83.6%) were male while 10 (16.4%) were female with male to female ratio of 5:1. Thirty - eight (62.3%) patients were aged 20-39 years. Forty two patients (68.9%) presented after one week of injury. No patient presented within the first six hours of injury. The symptoms needing referral for CT scan included head injury 30 (49.2%), seizures 10 16.4%), skull fractures 8 (13.1%) and persistent headache 6 (5.6%). A total of 113 lesions were seen as some patients presented with more than one lesion. The findings on CT scan included 10 patients with normal findings , 21 (34.4%) skull fractures , 21 (34.4%) intra-cerebral haemorrhage , 19 (31.2%) brain contusion , 18 (29.5%) paranasal sinus collection,11 (18.0%) cerebral oedema, 10 (16.4%) subdural haematoma and 5 (8.2%) epidural haematoma. Over 80% of the subdural and epidural haematomas were associated with skull fractures. The yield from plain radiography was poor being positive in only 8 (13.1%) while CT scan was positive in 51 (83.61%). Also 75 (about 66%) of the 113 lesions seen on CT scan were treatable surgically. CT scan is an effective imaging modality of patient with road traffic accident and should be promptly requested in symptomatic patients who sustain trauma to the head toward identification of lesions that are amenable to surgical treatment.
... cross-sectional pictures of your body. Doctors use CT scans to look for Broken bones Cancers Blood clots Signs of heart disease Internal bleeding During a CT scan, you lie still on a table. The table ...
Validating automatic semantic annotation of anatomy in DICOM CT images
NASA Astrophysics Data System (ADS)
Pathak, Sayan D.; Criminisi, Antonio; Shotton, Jamie; White, Steve; Robertson, Duncan; Sparks, Bobbi; Munasinghe, Indeera; Siddiqui, Khan
2011-03-01
In the current health-care environment, the time available for physicians to browse patients' scans is shrinking due to the rapid increase in the sheer number of images. This is further aggravated by mounting pressure to become more productive in the face of decreasing reimbursement. Hence, there is an urgent need to deliver technology which enables faster and effortless navigation through sub-volume image visualizations. Annotating image regions with semantic labels such as those derived from the RADLEX ontology can vastly enhance image navigation and sub-volume visualization. This paper uses random regression forests for efficient, automatic detection and localization of anatomical structures within DICOM 3D CT scans. A regression forest is a collection of decision trees which are trained to achieve direct mapping from voxels to organ location and size in a single pass. This paper focuses on comparing automated labeling with expert-annotated ground-truth results on a database of 50 highly variable CT scans. Initial investigations show that regression forest derived localization errors are smaller and more robust than those achieved by state-of-the-art global registration approaches. The simplicity of the algorithm's context-rich visual features yield typical runtimes of less than 10 seconds for a 5123 voxel DICOM CT series on a single-threaded, single-core machine running multiple trees; each tree taking less than a second. Furthermore, qualitative evaluation demonstrates that using the detected organs' locations as index into the image volume improves the efficiency of the navigational workflow in all the CT studies.
NASA Astrophysics Data System (ADS)
Wormanns, Dag; Klotz, Ernst; Dregger, Uwe; Beyer, Florian; Heindel, Walter
2004-05-01
Lack of angiogenesis virtually excludes malignancy of a pulmonary nodule; assessment with quantitative contrast-enhanced CT (QECT) requires a reliable enhancement measurement technique. Diagnostic performance of different measurement methods in the distinction between malignant and benign nodules was evaluated. QECT (unenhanced scan and 4 post-contrast scans) was performed in 48 pulmonary nodules (12 malignant, 12 benign, 24 indeterminate). Nodule enhancement was the difference between the highest nodule density at any post-contrast scan and the unenhanced scan. Enhancement was determined with: A) the standard 2D method; B) a 3D method consisting of segmentation, removal of peripheral structures and density averaging. Enhancement curves were evaluated for their plausibility using a predefined set of criteria. Sensitivity and specificity were 100% and 33% for the 2D method resp. 92% and 55% for the 3D method using a threshold of 20 HU. One malignant nodule did not show significant enhancement with method B due to adjacent atelectasis which disappeared within the few minutes of the QECT examination. Better discrimination between benign and malignant lesions was achieved with a slightly higher threshold than proposed in the literature. Application of plausibility criteria to the enhancement curves rendered less plausibility faults with the 3D method. A new 3D method for analysis of QECT scans yielded less artefacts and better specificity in the discrimination between benign and malignant pulmonary nodules when using an appropriate enhancement threshold. Nevertheless, QECT results must be interpreted with care.
[Preoperative CT Scan in middle ear cholesteatoma].
Sethom, Anissa; Akkari, Khemaies; Dridi, Inès; Tmimi, S; Mardassi, Ali; Benzarti, Sonia; Miled, Imed; Chebbi, Mohamed Kamel
2011-03-01
To compare preoperative CT scan finding and per-operative lesions in patients operated for middle ear cholesteatoma, A retrospective study including 60 patients with cholesteatoma otitis diagnosed and treated within a period of 5 years, from 2001 to 2005, at ENT department of Military Hospital of Tunis. All patients had computed tomography of the middle and inner ear. High resolution CT scan imaging was performed using millimetric incidences (3 to 5 millimetres). All patients had surgical removal of their cholesteatoma using down wall technic. We evaluated sensitivity, specificity and predictive value of CT-scan comparing otitic damages and CT finding, in order to examine the real contribution of computed tomography in cholesteatoma otitis. CT scan analysis of middle ear bone structures shows satisfaction (with 83% of sensibility). The rate of sensibility decrease (63%) for the tympanic raff. Predictive value of CT scan for the diagnosis of cholesteatoma was low. However, we have noticed an excellent sensibility in the analysis of ossicular damages (90%). Comparative frontal incidence seems to be less sensible for the detection of facial nerve lesions (42%). But when evident on CT scan findings, lesions of facial nerve were usually observed preoperatively (spécificity 78%). Predictive value of computed tomography for the diagnosis of perilymphatic fistulae (FL) was low. In fact, CT scan imaging have showed FL only for four patients among eight. Best results can be obtained if using inframillimetric incidences with performed high resolution computed tomography. Preoperative computed tomography is necessary for the diagnosis and the evaluation of chronic middle ear cholesteatoma in order to show extending lesion and to detect complications. This CT analysis and surgical correlation have showed that sensibility, specificity and predictive value of CT-scan depend on the anatomic structure implicated in cholesteatoma damages.
Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka
In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guidemore » provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.« less
Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute
NASA Astrophysics Data System (ADS)
Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús
2014-11-01
In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.
Biola, Holly; Best, Randall M; Lahlou, Rita M; Burke, Lauren M; Dewar, Charles; Jackson, Carlos T; Broder, Joshua; Grey, Linda; Semelka, Richard C; Dobson, Allen
2014-01-01
Patients are being exposed to increasing levels of ionizing radiation, much of it from computed tomography (CT) scans. Adults without a cancer diagnosis who received 10 or more CT scans in 2010 were identified from North Carolina Medicaid claims data and were sent a letter in July 2011 informing them of their radiation exposure; those who had undergone 20 or more CT scans in 2010 were also telephoned. The CT scan exposure of these high-exposure patients during the 12 months following these interventions was compared with that of adult Medicaid patients without cancer who had at least 1 CT scan but were not in the intervention population. The average number of CT scans per month for the high-exposure population decreased over time, but most of that reduction occurred 6-9 months before our interventions took place. At about the same time, the number of CT scans per month also decreased in adult Medicaid patients without cancer who had at least 1 CT scan but were not in the intervention population. Our data do not include information about CT scans that may have been performed during times when patients were not covered by Medicaid. Some of our letters may not have been received or understood. Some high-exposure patients were unintentionally excluded from our study because organization of data on Medicaid claims varies by setting of care. Our patient education intervention was not temporally associated with significant decreases in subsequent CT exposure. Effecting behavior change to reduce exposure to ionizing radiation requires more than an educational letter or telephone call.
NASA Astrophysics Data System (ADS)
Liu, Junting; Tian, Jie; Liang, Jimin; Li, Xiangsi; Yang, Xiang; Chen, Xiaofeng; Chen, Yi; Zhou, Yuanfang; Wang, Xiaorui
2011-03-01
Immunocytochemical and immunofluorescence staining are used for identifying the characteristics of metastasis in traditional ways. Micro-computed tomography (micro-CT) is a useful tool for monitoring and longitudinal imaging of tumor in small animal in vivo. In present study, we evaluated the feasibility of the detection for metastasis of gastric carcinoma by high-resolution micro-CT system with omnipaque accumulative enhancement method in the organs. Firstly, a high-resolution micro-CT ZKKS-MCT-sharp micro-CT was developed by our research group and Guangzhou Zhongke Kaisheng Medical Technology Co., Ltd. Secondly, several gastric carcinoma models were established through inoculating 2x106 BGC-823 gastric carcinoma cells subcutaneously. Thirdly, micro-CT scanning was performed after accumulative enhancement method of intraperitoneal injection of omnipaque contrast agent containing 360 mg iodine with a concentration of 350 mg I/ml. Finally, we obtained high-resolution anatomical information of the metastasis in vivo in a BALB/c NuNu nude mouse, the 3D tumor architecture is revealed in exquisite detail at about 35 μm spatial resolution. In addition, the accurate shape and volume of the micrometastasis as small as 0.78 mm3 can be calculated with our software. Overall, our data suggest that this imaging approach and system could be used to enhance the understanding of tumor proliferation, metastasis and could be the basis for evaluating anti-tumor therapies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noid, G; Tai, A; Liu, Y
Purpose: It is desirable to increase CT soft-tissue contrast to improve delineation of tumor target and/or surrounding organs at risk (OAR) in RT planning and delivery guidance. The purpose of this work is to investigate the use of monoenergetic decompositions obtained from dual energy (DE) CT to improve soft-tissue contrast. Methods: CT data were acquired for 5 prostate and 5 pancreas patients and a phantom with a CT Scanner (Definition AS Open, Siemens) using both sequential DE protocols and standard protocols. For the DE protocols, the scanner rapidly performs two acquisitions at 80 kVp and 140 kVp. The CT numbersmore » of soft tissue inserts in the phantom (CTED/Gammex) were measured across the spectrum of available monoenergetic decompositions (40 to 140 keV) and compared to the standard protocol (120 kVp, 0.6 pitch, 18 mGy CTDIvol). Contrast, defined as the difference in the average CT number between target and OAR, was measured for all subjects and compared between the DE and standard protocols. Results: Mono-energetic decompositions of the phantom demonstrate an enhancement of soft-tissue contrast as the energy is decreased. For instance, relative to the 120 kVp scans the Liver ED insert increased in CT number by 25 HU while the adipose ED insert decreased by 50 HU. The lowest energy decompositions featured the highest contrast between target and OAR. For every patient, the contrast increased by decomposing at 40 keV. The average increase in contrast relative to a 120 kVp scan for prostate patients at 40 keV was 25.05±17.28 HU while for pancreas patients it was 19.21±17.39 HU. Conclusion: Low energy monoenergetic decompositions from dual-energy CT substantially increase soft-tissue contrast. At the lowest achievable monoenergetic decompositions the maximum soft-tissue contrast is achieved and the delineation of target and OAR is improved. Thus it is beneficial to use DECT in radiation oncology. Supported by Siemens.« less
Value of repeat CT scans in low back pain and radiculopathy.
Schroeder, Josh E; Barzilay, Yair; Kaplan, Leon; Itshayek, Eyal; Hiller, Nurith
2016-02-01
We assessed the clinical value of repeat spine CT scan in 108 patients aged 18-60 years who underwent repeat lumbar spine CT scan for low back pain or radiculopathy from January 2008 to December 2010. Patients with a neoplasm or symptoms suggesting underlying disease were excluded from the study. Clinical data was retrospectively reviewed. Index examinations and repeat CT scan performed at a mean of 24.3 ± 11.3 months later were compared by a senior musculoskeletal radiologist. Disc abnormalities (herniation, sequestration, bulge), spinal stenosis, disc space narrowing, and bony changes (osteophytes, fractures, other changes) were documented. Indications for CT scan were low back pain (60 patients, 55%), radiculopathy (46 patients, 43%), or nonspecific back pain (two patients, 2%). A total of 292 spine pathologies were identified in 98 patients (90.7%); in 10 patients (9.3%) no spine pathology was seen on index or repeat CT scan. At repeat CT scan, 269/292 pathologies were unchanged (92.1%); 10/292 improved (3.4%), 8/292 worsened (2.8%, disc herniation or spinal stenosis), and five new pathologies were identified. No substantial therapeutic change was required in patients with worsened or new pathology. Added diagnostic value from repeat CT scan performed within 2-3 years was rare in patients suffering chronic or recurrent low back pain or radiculopathy, suggesting that repeat CT scan should be considered only in patients with progressive neurologic deficits, new neurologic complaints, or signs implying serious underlying conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.
Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT.
Pan, Tinsu
2005-02-01
We proposed a data sufficiency condition (DSC) for four-dimensional-CT (4D-CT) imaging on a multislice CT scanner, designed a pitch factor for a helical 4D-CT, and compared the acquisition time, slice sensitivity profile (SSP), effective dose, ability to cope with an irregular breathing cycle, and gating technique (retrospective or prospective) of the helical 4D-CT and the cine 4D-CT on the General Electric (GE) LightSpeed RT (4-slice), Plus (4-slice), Ultra (8-slice) and 16 (16-slice) multislice CT scanners. To satisfy the DSC, a helical or cine 4D-CT acquisition has to collect data at each location for the duration of a breathing cycle plus the duration of data acquisition for an image reconstruction. The conditions for the comparison were 20 cm coverage in the cranial-caudal direction, a 4 s breathing cycle, and half-scan reconstruction. We found that the helical 4D-CT has the advantage of a shorter scan time that is 10% shorter than that of the cine 4D-CT, and the disadvantages of 1.8 times broadening of SSP and requires an additional breathing cycle of scanning to ensure an adequate sampling at the start and end locations. The cine 4D-CT has the advantages of maintaining the same SSP as slice collimation (e.g., 8 x 2.5 mm slice collimation generates 2.5 mm SSP in the cine 4D-CT as opposed to 4.5 mm in the helical 4D-CT) and a lower dose by 4% on the 8- and 16-slice systems, and 8% on the 4-slice system. The advantage of faster scanning in the helical 4D-CT will diminish if a repeat scan at the location of a breathing irregularity becomes necessary. The cine 4D-CT performs better than the helical 4D-CT in the repeat scan because it can scan faster and is more dose efficient.
Reduction in radiation doses from paediatric CT scans in Great Britain.
Lee, Choonsik; Pearce, Mark S; Salotti, Jane A; Harbron, Richard W; Little, Mark P; McHugh, Kieran; Chapple, Claire-Louise; Berrington de Gonzalez, Amy
2016-01-01
Although CT scans provide great medical benefits, concerns have been raised about the magnitude of possible associated cancer risk, particularly in children who are more sensitive to radiation than adults. Unnecessary high doses during CT examinations can also be delivered to children, if the scan parameters are not adjusted for patient age and size. We conducted the first survey to directly assess the trends in CT scan parameters and doses for paediatric CT scans performed in Great Britain between 1978 and 2008. We retrieved 1073 CT film sets from 36 hospitals. The patients were 0-19 years old, and CT scans were conducted between 1978 and 2008. We extracted scan parameters from each film including tube current-time product [milliampere seconds (mAs)], tube potential [peak kilovoltage (kVp)] and manufacturer and model of the CT scanner. We estimated the mean mAs for head and trunk (chest and abdomen/pelvis) scans, according to patient age (0-4, 5-9, 10-14 and 15-19 years) and scan year (<1990, 1990-1994, 1995-1999 and ≥2000), and then derived the volumetric CT dose index and estimated organ doses. For head CT scans, mean mAs decreased by about 47% on average from before 1990 to after 2000, with the decrease starting around 1990. The mean mAs for head CTs did not vary with age before 1990, whereas slightly lower mAs values were used for younger patients after 1990. Similar declines in mAs were observed for trunk CTs: a 46% decline on an average from before 1990 to after 2000. Although mean mAs for trunk CTs did not vary with age before 1990, the value varied markedly by age, from 63 mAs for age 0-4 years compared with 315 mAs for those aged >15 years after 2000. No material changes in kVp were found. Estimated brain-absorbed dose from head CT scans decreased from 62 mGy before 1990 to approximately 30 mGy after 2000. For chest CT scans, the lung dose to children aged 0-4 years decreased from 28 mGy before 1990 to 4 mGy after 2000. We found that mAs for head and trunk CTs was approximately halved starting around 1990, and age-specific mAs was generally used for paediatric scans after this date. These changes will have substantially reduced the radiation exposure to children from CT scans in Great Britain. The study shows that mAs and major organ doses for paediatric CT scans in Great Britain began to decrease around 1990.
Reduction in radiation doses from paediatric CT scans in Great Britain
Pearce, Mark S; Salotti, Jane A; Harbron, Richard W; Little, Mark P; McHugh, Kieran; Chapple, Claire-Louise; Berrington de Gonzalez, Amy
2016-01-01
Objective: Although CT scans provide great medical benefits, concerns have been raised about the magnitude of possible associated cancer risk, particularly in children who are more sensitive to radiation than adults. Unnecessary high doses during CT examinations can also be delivered to children, if the scan parameters are not adjusted for patient age and size. We conducted the first survey to directly assess the trends in CT scan parameters and doses for paediatric CT scans performed in Great Britain between 1978 and 2008. Methods: We retrieved 1073 CT film sets from 36 hospitals. The patients were 0–19 years old, and CT scans were conducted between 1978 and 2008. We extracted scan parameters from each film including tube current–time product [milliampere seconds (mAs)], tube potential [peak kilovoltage (kVp)] and manufacturer and model of the CT scanner. We estimated the mean mAs for head and trunk (chest and abdomen/pelvis) scans, according to patient age (0–4, 5–9, 10–14 and 15–19 years) and scan year (<1990, 1990–1994, 1995–1999 and ≥2000), and then derived the volumetric CT dose index and estimated organ doses. Results: For head CT scans, mean mAs decreased by about 47% on average from before 1990 to after 2000, with the decrease starting around 1990. The mean mAs for head CTs did not vary with age before 1990, whereas slightly lower mAs values were used for younger patients after 1990. Similar declines in mAs were observed for trunk CTs: a 46% decline on an average from before 1990 to after 2000. Although mean mAs for trunk CTs did not vary with age before 1990, the value varied markedly by age, from 63 mAs for age 0–4 years compared with 315 mAs for those aged >15 years after 2000. No material changes in kVp were found. Estimated brain-absorbed dose from head CT scans decreased from 62 mGy before 1990 to approximately 30 mGy after 2000. For chest CT scans, the lung dose to children aged 0–4 years decreased from 28 mGy before 1990 to 4 mGy after 2000. Conclusion: We found that mAs for head and trunk CTs was approximately halved starting around 1990, and age-specific mAs was generally used for paediatric scans after this date. These changes will have substantially reduced the radiation exposure to children from CT scans in Great Britain. Advances in knowledge: The study shows that mAs and major organ doses for paediatric CT scans in Great Britain began to decrease around 1990. PMID:26864156
Short- and long-term effects of clinical audits on compliance with procedures in CT scanning.
Oliveri, Antonio; Howarth, Nigel; Gevenois, Pierre Alain; Tack, Denis
2016-08-01
To test the hypothesis that quality clinical audits improve compliance with the procedures in computed tomography (CT) scanning. This retrospective study was conducted in two hospitals, based on 6950 examinations and four procedures, focusing on the acquisition length in lumbar spine CT, the default tube current applied in abdominal un-enhanced CT, the tube potential selection for portal phase abdominal CT and the use of a specific "paediatric brain CT" procedure. The first clinical audit reported compliance with these procedures. After presenting the results to the stakeholders, a second audit was conducted to measure the impact of this information on compliance and was repeated the next year. Comparisons of proportions were performed using the Chi-square Pearson test. Depending on the procedure, the compliance rate ranged from 27 to 88 % during the first audit. After presentation of the audit results to the stakeholders, the compliance rate ranged from 68 to 93 % and was significantly improved for all procedures (P ranging from <0.001 to 0.031) in both hospitals and remained unchanged during the third audit (P ranging from 0.114 to 0.999). Quality improvement through repeated compliance audits with CT procedures durably improves this compliance. • Compliance with CT procedures is operator-dependent and not perfect. • Compliance differs between procedures and hospitals, even within a unified department. • Compliance is improved through audits followed by communication to the stakeholders. • This improvement is sustainable over a one-year period.
Full-Body CT Scans - What You Need to Know
... Medical Imaging Medical X-ray Imaging Full-Body CT Scans - What You Need to Know Share Tweet ... new service for health-conscious people: "Whole-body CT screening." This typically involves scanning the body from ...
Characteristic CT and MR imaging findings of cerebral paragonimiasis.
Xia, Yong; Chen, Jing; Ju, Yan; You, Chao
2016-06-01
The early diagnosis of cerebral paragonimiasis (CP) is essential for a good prognosis. We seek to provide references for early diagnosis by analyzing the imaging characteristics of cerebral paragonimiasis. Images of 27 patients with CP (22 males and 5 females; median age 20.3 years; range: 4 to 47 years) were retrospectively evaluated. All patients underwent head computed tomography (CT) scans; 22 patients underwent conventional magnetic resonance imaging (MRI) sequences, including contrast-enhanced MRI for 20 patients and diffusion-weighted-imaging (DWI) for 1 patient. The diagnosis was confirmed based on a positive antibody test using enzyme-linked immunosorbent assay (ELISA) for paragonimiasis in the serum. The most common imaging findings of CP were isodense or hypodense lesions combined with extensive hypodense areas of perilesional edema on CT scans and a large mass composed of multiple ring-shaped lesions with surrounding edema on MRI images. The conglomeration of multiple ring-shaped lesions (n=11 patients), "tunnel signs" (n=12 patients) and worm-eaten signs (n=5 patients) were characteristic of most CP images. In 14 patients, contrast-enhanced MRI showed varying degrees of contrast enhancement combined with adjacent meningeal enhancement (n=10). A large mass comprising multiple ring-shaped lesions of different sizes, "tunnel signs" and worm-eaten signs with surrounding edema are the most characteristic features of CP. Extensive invasions of the adjacent meninges and ventricular wall (19 patients), multiple intracerebral lesions, bilateral hemispheric involvement, and lesion migration are other noteworthy imaging characteristics. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Pollard, R E; Fuller, M C; Steffey, M A
2017-06-01
In this prospective study, we hypothesized that computed tomography (CT) would identify more normal and abnormal iliosacral lymph nodes (LNs) than abdominal ultrasound in dogs with anal sac gland carcinoma (ASGC). Twelve client-owned dogs with ASGC but without distant metastasis were enrolled. Abdominal ultrasound and contrast-enhanced CT scans of the abdomen were obtained. Iliosacral LNs were counted and assessed for location, laterality and size. Significantly (P < 0.00001) more iliosacral LNs were identified with CT (61) than ultrasound (30), including significantly (P = 0.00012) more medial iliac LNs with CT (33) than ultrasound (19). There was no difference in number of internal iliac LNs identified with CT versus ultrasound. Significantly (P = 0.000061) more sacral LNs were identified with CT (15) than ultrasound (0). Ultrasound identified slightly more (7) abnormal iliosacral LNs than CT (5). Contrast CT was able to identify more normal but not more abnormal LNs than ultrasound. © 2015 John Wiley & Sons Ltd.
Sensitivity and daily quality control of a mobile PET/CT scanner operating in 3-dimensional mode.
Belakhlef, Abdelfatihe; Church, Clifford; Fraser, Ron; Lakhanpal, Suresh
2007-12-01
This study investigated the stability of the sensitivity of a mobile PET/CT scanner and tested a phantom experiment to improve on the daily quality control recommendations of the manufacturer. Unlike in-house scanners, mobile PET/CT devices are subjected to a harsher, continuously changing environment that can alter their performance. The parameter of sensitivity was investigated because it reflects directly on standardized uptake value, a key factor in cancer evaluation. A (68)Ge phantom of known activity concentration was scanned 6 times a month for 11 consecutive months using a mobile PET/CT scanner that operates in 3-dimensional mode only. The scans were acquired as 2 contiguous bed positions, with raw data obtained and reconstructed using parameters identical to those used for oncology patients, including CT-extracted attenuation coefficients and decay, scatter, geometry, and randoms corrections. After visual inspection of all reconstructed images, identical regions of interest were drawn on each image to obtain the activity concentration of individual slices. The original activity concentration was then decay-corrected to the scanning day, and the percentage sensitivity of the slice was calculated and graphed. The daily average sensitivity of the scanner, over 11 consecutive months, was also obtained and used to evaluate the stability of sensitivity. Our particular scanner showed a daily average sensitivity ranging from -8.6% to 6.5% except for one instance, when the sensitivity dropped by an unacceptable degree, 34.8%. Our 11-mo follow-up of a mobile PET/CT scanner demonstrated that its sensitivity remained within acceptable clinical limits except for one instance, when the scanner had to be serviced before patients could be imaged. To enhance our confidence in the uniformity of sensitivity across slices, we added a phantom scan to the daily quality control recommendations of the manufacturer.
2014-01-01
Background and purpose It is difficult to evaluate glenoid component periprosthetic radiolucencies in total shoulder arthroplasties (TSAs) using plain radiographs. This study was performed to evaluate whether computed tomography (CT) using a specific patient position in the CT scanner provides a better method for assessing radiolucencies in TSA. Methods Following TSA, 11 patients were CT scanned in a lateral decubitus position with maximum forward flexion, which aligns the glenoid orientation with the axis of the CT scanner. Follow-up CT scanning is part of our routine patient care. Glenoid component periprosthetic lucency was assessed according to the Molé score and it was compared to routine plain radiographs by 5 observers. Results The protocol almost completely eliminated metal artifacts in the CT images and allowed accurate assessment of periprosthetic lucency of the glenoid fixation. Positioning of the patient within the CT scanner as described was possible for all 11 patients. A radiolucent line was identified in 54 of the 55 observed CT scans and osteolysis was identified in 25 observations. The average radiolucent line Molé score was 3.4 (SD 2.7) points with plain radiographs and 9.5 (SD 0.8) points with CT scans (p = 0.001). The mean intra-observer variance was lower in the CT scan group than in the plain radiograph group (p = 0.001). Interpretation The CT scan protocol we used is of clinical value in routine assessment of glenoid periprosthetic lucency after TSA. The technique improves the ability to detect and monitor radiolucent lines and, therefore, possibly implant loosening also. PMID:24286563
Aziz, Farooq; Ihsan, Ayesha; Nazir, Aalia; Ahmad, Ishaq; Bajwa, Sadia Zafar; Rehman, Asma; Diallo, Abdoulaye; Khan, Waheed S
2017-01-01
Gold nanoparticles (GNPs) with dimension in the range of 1-100 nm have a prominent role in a number of biomedical applications like imaging, drug delivery, and cancer therapy owing to their unique optical features and biocompatibility. In this work, we report a novel technique for the synthesis of two types of GNPs namely porous gold nanoparticles (PGNPs) and solid gold nanoparticles (SGNPs). PGNPs of size 35 nm were fabricated by reduction of gold (III) solution with lecithin followed by addition of L-ascorbic acid and tri-sodium citrate, whereas SGNPs with a dimension of 28 nm were prepared by reflux method using lecithin as a single reducing agent. Comparative studies using PGNPs (λ max 560 nm) and SGNPs (λ max 548 nm) were conducted for evaluating their use as a contrast agent. These studies reveled that in direct computed tomography scan, PGNPs exhibited brighter contrast (45 HU) than SGNPs (26 HU). To investigate the effect of PGNPs and SGNPs on the liver and kidney profile, male rabbits were intravenously injected with an equal dose of 1 mg/kg weight of PGNPs and SGNPs. The effect on biochemical parameters was evaluated 72 hours after intravenous (IV) injection including liver function profile, renal (kidney) function biomarker, random blood glucose value, and cholesterol level. During one comparison of contrast in CT scan, PGNPs showed significantly enhanced contrast in whole-rabbit and organ CT scan as compared to SGNPs 6 hours after injection. Our findings suggested that the novel PGNPs enhance CT scan image with higher efficacy as compared to SGNPs. The results showed that IV administration of synthesized PGNPs increases the levels of aspartate aminotransferase (AST), alkaline phosphate (ALP), serum creatinine, and blood glucose, whereas that of SGNPs increases the levels of AST, ALP, and blood glucose.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, W; Xue, M; Patel, K
2015-06-15
Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) andmore » the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.« less
Comparative analysis of semantic localization accuracies between adult and pediatric DICOM CT images
NASA Astrophysics Data System (ADS)
Robertson, Duncan; Pathak, Sayan D.; Criminisi, Antonio; White, Steve; Haynor, David; Chen, Oliver; Siddiqui, Khan
2012-02-01
Existing literature describes a variety of techniques for semantic annotation of DICOM CT images, i.e. the automatic detection and localization of anatomical structures. Semantic annotation facilitates enhanced image navigation, linkage of DICOM image content and non-image clinical data, content-based image retrieval, and image registration. A key challenge for semantic annotation algorithms is inter-patient variability. However, while the algorithms described in published literature have been shown to cope adequately with the variability in test sets comprising adult CT scans, the problem presented by the even greater variability in pediatric anatomy has received very little attention. Most existing semantic annotation algorithms can only be extended to work on scans of both adult and pediatric patients by adapting parameters heuristically in light of patient size. In contrast, our approach, which uses random regression forests ('RRF'), learns an implicit model of scale variation automatically using training data. In consequence, anatomical structures can be localized accurately in both adult and pediatric CT studies without the need for parameter adaptation or additional information about patient scale. We show how the RRF algorithm is able to learn scale invariance from a combined training set containing a mixture of pediatric and adult scans. Resulting localization accuracy for both adult and pediatric data remains comparable with that obtained using RRFs trained and tested using only adult data.
Chest CT in children: anesthesia and atelectasis.
Newman, Beverley; Krane, Elliot J; Gawande, Rakhee; Holmes, Tyson H; Robinson, Terry E
2014-02-01
There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain reliable and reproducible high-quality, motion-free chest CT images in children.
Window classification of brain CT images in biomedical articles.
Xue, Zhiyun; Antani, Sameer; Long, L Rodney; Demner-Fushman, Dina; Thoma, George R
2012-01-01
Effective capability to search biomedical articles based on visual properties of article images may significantly augment information retrieval in the future. In this paper, we present a new method to classify the window setting types of brain CT images. Windowing is a technique frequently used in the evaluation of CT scans, and is used to enhance contrast for the particular tissue or abnormality type being evaluated. In particular, it provides radiologists with an enhanced view of certain types of cranial abnormalities, such as the skull lesions and bone dysplasia which are usually examined using the " bone window" setting and illustrated in biomedical articles using "bone window images". Due to the inherent large variations of images among articles, it is important that the proposed method is robust. Our algorithm attained 90% accuracy in classifying images as bone window or non-bone window in a 210 image data set.
Niu, Zhong-Xi; Zhang, Hang; Chen, Long-Qi; Shi, Hui; Peng, Jun; Su, Li-Wei; Li, Wei; Xiao, Bo; He, Shu; Yue, Hong-Xu
2017-01-01
The non-recurrent laryngeal nerve (NRLN) is a rare but potentially serious anomaly that is commonly associated with the aberrant right subclavian artery (ARSA). It is easy to damage during surgical resection of esophageal cancer, leading to severe complications. Preoperative enhanced thoracic computed tomography (CT) scans of 2697 patients with esophageal carcinoma treated in our hospital between January 2010 and December 2013 were examined. We classified the positional relationship between the right subclavian artery and the membranous wall of the trachea into two types and used this method to predicate NRLN by identifying ARSA. Twenty-six patients (0.96%) were identified with ARSA, all of which were cases of NRLN by CT. NRLN was identified during surgery in the 26 patients, and a normal right recurrent laryngeal nerve was observed in 2671 patients. The ARSA was detected on the dorsal side of the membranous wall of the trachea in all 26 NRLN cases, while it was detected on the ventral side in all 2671 recurrent laryngeal nerve cases. Enhanced CT scanning is a reliable method for predicting NRLN by identifying ARSA. Preoperative recognition of this nerve anomaly allows surgeons to avoid damaging the nerve and abnormal vessels during esophagectomy. © 2016 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.
Leen, Edward; Ceccotti, Piercarlo; Moug, Susan J; Glen, Paul; MacQuarrie, John; Angerson, Wilson J; Albrecht, Thomas; Hohmann, Joachim; Oldenburg, Anja; Ritz, Jorg Peter; Horgan, Paul G
2006-02-01
The aim of the study was to assess the clinical value of contrast-enhanced intraoperative ultrasound (CE-IOUS) as a novel tool in the hepatic staging of patients undergoing liver resection. Sixty patients scheduled to undergo liver resection for metastatic disease were studied. Preoperative staging with contrast-enhanced CT and/or MR scans was performed within 2 to 6 weeks of operation. Following exploration, intraoperative ultrasound (IOUS) was performed using an HDI-5000 scanner (Philips) and a finger-probe with pulse inversion harmonic (PIH) capability. CE-IOUS in the PIH mode was performed in a standardized protocol (low MI: 0.02-0.04) after intravenous injection of 3-4 mL of SonoVue (Bracco spa, Milan); all detected lesions on precontrast and postcontrast scans were counted and mapped. Any alteration in surgical management was documented following CE-IOUS compared with IOUS. Three patients were excluded due to disseminated disease on exploration. CE-IOUS was significantly more sensitive than CT/MR and IOUS in detecting liver metastases (96.1% versus 76.7% and 81.5%, respectively) (P<0.05); it altered surgical management in 29.8% (17 of 57) of cases, due to 1) additional metastases in 19.3% (11 of 57), 2) less metastases in 3.5% (2 of 57), 3) benign lesions wrongly diagnosed as metastasis on IOUS/CT in 5.3% (3 of 57), and 4) vascular proximity in 1.8% (1 of 57). Management was unchanged in 70.2% (40 of 57) despite additional lesions detected in 3.5% (2 of 57) and benign lesion wrongly diagnosed on IOUS and CT as metastasis in 1.8% (1 of 57). CE-IOUS altered combined IOUS/CT/MR staging in 35.1%. These preliminary results suggest CE-IOUS is an essential tool prior to liver resection for metastases.
Imaging and Clinicopathologic Features of Esophageal Gastrointestinal Stromal Tumors
Winant, Abbey J.; Gollub, Marc J.; Shia, Jinru; Antonescu, Christina; Bains, Manjit S.; Levine, Marc S.
2016-01-01
OBJECTIVE The purpose of this article is to describe the imaging and clinicopathologic characteristics of esophageal gastrointestinal stromal tumors (GISTs) and to emphasize the features that differentiate esophageal GISTs from esophageal leiomyomas. MATERIALS AND METHODS A pathology database search identified all surgically resected or biopsied esophageal GISTs, esophageal leiomyomas, and esophageal leiomyosarcomas from 1994 to 2012. Esophageal GISTs were included only if imaging studies (including CT, fluoroscopic, or 18F-FDG PET/CT scans) and clinical data were available. RESULTS Nineteen esophageal mesenchymal tumors were identified, including eight esophageal GISTs (42%), 10 esophageal leiomyomas (53%), and one esophageal leiomyosarcoma (5%). Four patients (50%) with esophageal GIST had symptoms, including dysphagia in three (38%), cough in one (13%), and chest pain in one (13%). One esophageal GIST appeared on barium study as a smooth submucosal mass. All esophageal GISTs appeared on CT as well-marginated predominantly distal lesions, isoattenuating to muscle, that moderately enhanced after IV contrast agent administration. Compared with esophageal leiomyomas, esophageal GISTs tended to be more distal, larger, and more heterogeneous and showed greater IV enhancement on CT. All esophageal GISTs showed marked avidity (mean maximum standardized uptake value, 16) on PET scans. All esophageal GISTs were positive for c-KIT (a cell-surface transmembrane tyrosine kinase also known as CD117) and CD34. On histopathology, six esophageal GISTs (75%) were of the spindle pattern and two (25%) were of a mixed spindle and epithelioid pattern. Five esophageal GISTs had exon 11 mutations (with imatinib sensitivity). Clinical outcome correlated with treatment strategy (resection plus adjuvant therapy or resection alone) rather than risk stratification. CONCLUSION Esophageal GISTs are unusual but clinically important mesenchymal neoplasms. Although esophageal GISTs and esophageal leiomyomas had overlapping imaging features, esophageal GISTs tended to be more distal, larger, more heterogeneous, and more enhancing on CT and were markedly FDG avid on PET. Given their malignant potential, esophageal GISTs should be included in the differential diagnosis of intramural esophageal neoplasms. PMID:25055264
Cotter, Meghan M.; Whyms, Brian J.; Kelly, Michael P.; Doherty, Benjamin M.; Gentry, Lindell R.; Bersu, Edward T.; Vorperian, Houri K.
2015-01-01
The hyoid bone anchors and supports the vocal tract. Its complex shape is best studied in three dimensions, but it is difficult to capture on computed tomography (CT) images and three-dimensional volume renderings. The goal of this study was to determine the optimal CT scanning and rendering parameters to accurately measure the growth and developmental anatomy of the hyoid and to determine whether it is feasible and necessary to use these parameters in the measurement of hyoids from in vivo CT scans. Direct linear and volumetric measurements of skeletonized hyoid bone specimens were compared to corresponding CT images to determine the most accurate scanning parameters and three-dimensional rendering techniques. A pilot study was undertaken using in vivo scans from a retrospective CT database to determine feasibility of quantifying hyoid growth. Scanning parameters and rendering technique affected accuracy of measurements. Most linear CT measurements were within 10% of direct measurements; however, volume was overestimated when CT scans were acquired with a slice thickness greater than 1.25 mm. Slice-by-slice thresholding of hyoid images decreased volume overestimation. The pilot study revealed that the linear measurements tested correlate with age. A fine-tuned rendering approach applied to small slice thickness CT scans produces the most accurate measurements of hyoid bones. However, linear measurements can be accurately assessed from in vivo CT scans at a larger slice thickness. Such findings imply that investigation into the growth and development of the hyoid bone, and the vocal tract as a whole, can now be performed using these techniques. PMID:25810349
Cotter, Meghan M; Whyms, Brian J; Kelly, Michael P; Doherty, Benjamin M; Gentry, Lindell R; Bersu, Edward T; Vorperian, Houri K
2015-08-01
The hyoid bone anchors and supports the vocal tract. Its complex shape is best studied in three dimensions, but it is difficult to capture on computed tomography (CT) images and three-dimensional volume renderings. The goal of this study was to determine the optimal CT scanning and rendering parameters to accurately measure the growth and developmental anatomy of the hyoid and to determine whether it is feasible and necessary to use these parameters in the measurement of hyoids from in vivo CT scans. Direct linear and volumetric measurements of skeletonized hyoid bone specimens were compared with corresponding CT images to determine the most accurate scanning parameters and three-dimensional rendering techniques. A pilot study was undertaken using in vivo scans from a retrospective CT database to determine feasibility of quantifying hyoid growth. Scanning parameters and rendering technique affected accuracy of measurements. Most linear CT measurements were within 10% of direct measurements; however, volume was overestimated when CT scans were acquired with a slice thickness greater than 1.25 mm. Slice-by-slice thresholding of hyoid images decreased volume overestimation. The pilot study revealed that the linear measurements tested correlate with age. A fine-tuned rendering approach applied to small slice thickness CT scans produces the most accurate measurements of hyoid bones. However, linear measurements can be accurately assessed from in vivo CT scans at a larger slice thickness. Such findings imply that investigation into the growth and development of the hyoid bone, and the vocal tract as a whole, can now be performed using these techniques. © 2015 Wiley Periodicals, Inc.
Ozyer, Umut
2017-01-01
Spontaneous hematoma refractory to conservative management is a potentially serious condition that requires prompt diagnosis and intervention. The purpose of this study was to evaluate the performance of computed tomography (CT) in the treatment planning and to report the effectiveness of transcatheter embolization with N-butyl-2-cyanoacrylate (NBCA). Forty-one interventions in 38 patients within a 12-year period were evaluated. CT and angiograms were reviewed for the location of the hematoma, the presence of extravasation, and the correlation of CT and angiography findings. Arterial extravasation was present on 34/39 CT scans. Angiograms confirmed the CT scans in 29 cases. Angiograms revealed extravasation in four cases which CT showed venous bleeding (n = 2) or no bleeding (n = 2). Five patients with arterial and 1 patient with venous extravasation on CT images had no extravasation on angiograms. Embolization was performed to all arteries with extravasation on angiograms. Empiric embolization of the corresponding artery on the CT was performed when there was no extravasation on angiograms. Embolization procedures were performed with 15 % NBCA diluted with iodized oil. Technical success was achieved in 40/41 (97.6 %) interventions. Clinical success was achieved in 35 patients with a single, in 1 patient with 2, and in 1 patient with 3 interventions. No complications related to embolization procedure occurred. None of the patients died due to a progression of the hematoma. NBCA is an effective and safe embolic agent to treat hematoma refractory to conservative management. Contrast-enhanced CT may provide faster and more effective intervention. Retrospective.
Multi-detector row computed tomography angiography of peripheral arterial disease
Dijkshoorn, Marcel L.; Pattynama, Peter M. T.; Myriam Hunink, M. G.
2007-01-01
With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. PMID:17882427
Liver metastases: imaging considerations for protocol development with Multislice CT (MSCT)
Silverman, Paul M
2006-01-01
Conventional, single-slice helical computed tomography (SSCT) allowed for scanning the majority of the liver during the critical portal venous phase. This was often referred to as the ‘optimal temporal window’. The introduction of current day multislice CT (MSCT) now allows us to acquire images in a much shorter time and more precisely than ever before. This yields increased conspicuity between low attenuation lesions and the enhanced normal liver parenchyma and optimal imaging for the vast majority of hepatic hypovascular metastases. Most importantly, these scanners, when compared to conventional non-helical scanners, avoid impinging upon the ‘equilibrium’ phase when tumors can become isodense/invisible. MSCT also allows for true multiphase scanning during the arterial and late arterial phases for detection of hypervascular metastases. The MSCT imaging speed has increased significantly over the past years with the introduction of 32- and 64-detector systems and will continue to increase in the future volumetric CT. This provides a number of important gains that are discussed in detail. PMID:17098650
How Is Testicular Cancer Diagnosed?
... patients with non-seminoma. Many centers have special machines that can do both a PET and CT scan at the same time (PET/CT scan). This lets the doctor compare areas of higher radioactivity on the PET with the more detailed images of the CT. Bone scan A bone scan can help show if a ... Information, ...
Assessment of the effects of CT dose in averaged x-ray CT images of a dose-sensitive polymer gel
NASA Astrophysics Data System (ADS)
Kairn, T.; Kakakhel, M. B.; Johnston, H.; Jirasek, A.; Trapp, J. V.
2015-01-01
The signal-to-noise ratio achievable in x-ray computed tomography (CT) images of polymer gels can be increased by averaging over multiple scans of each sample. However, repeated scanning delivers a small additional dose to the gel which may compromise the accuracy of the dose measurement. In this study, a NIPAM-based polymer gel was irradiated and then CT scanned 25 times, with the resulting data used to derive an averaged image and a "zero-scan" image of the gel. Comparison between these two results and the first scan of the gel showed that the averaged and zero-scan images provided better contrast, higher contrast-to- noise and higher signal-to-noise than the initial scan. The pixel values (Hounsfield units, HU) in the averaged image were not noticeably elevated, compared to the zero-scan result and the gradients used in the linear extrapolation of the zero-scan images were small and symmetrically distributed around zero. These results indicate that the averaged image was not artificially lightened by the small, additional dose delivered during CT scanning. This work demonstrates the broader usefulness of the zero-scan method as a means to verify the dosimetric accuracy of gel images derived from averaged x-ray CT data.
Colloid Adenocarcinoma of the Lung: CT and PET/CT Findings in Seven Patients.
Kim, Han Kyul; Han, Joungho; Franks, Teri J; Lee, Kyung Soo; Kim, Tae Jung; Choi, Joon Young; Zo, Jaeil
2018-05-24
We aimed to assess CT and 18 F-FDG PET/CT findings of colloid adenocarcinoma of the lung in seven patients. From 2010 to 2017, seven patients with surgically proven colloid adenocarcinoma of the lung were identified. CT (both enhanced and unenhanced) and PET/CT findings were analyzed, and the imaging features were compared with histopathologic reports. Clinical and demographic features were also analyzed. In all cases except one, tumors showed low attenuation on unenhanced CT scans, ranging in attenuation from -16.5 to 20.7 HU (median, 9.2 HU). After contrast medium injection, enhancement was scant, so net enhancement ranged from 0.4 to 29.0 HU (median, 4.1 HU). All tumors had a lobulated contour. Stippled calcifications within the tumor were seen in one patient. The maximum standardized uptake value of tumors on PET/CT ranged from 1.5 to 4.5 (median, 3.5). In six of seven patients, FDG accumulation was seen in the tumor walls (n = 3, curvilinear uptake) or in both the tumor walls and tumor septa (n = 3, crisscross uptake). Six patients were alive without recurrence after a median follow-up period of 2.3 years (range, 2 months to 5 years). In one patient, who was alive at follow-up 4 years after imaging and had received adjuvant concurrent chemoradiation therapy after lobectomy, recurrent disease was detected 6 months after completion of the therapy. On CT, pulmonary colloid adenocarcinomas present as lobulated homogeneously low-attenuation tumors. At PET, curvilinear or crisscross FDG uptake is seen within the tumor where tumor cells are lining the walls or septal structures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noid, G; Tai, A; Li, X
2016-06-15
Purpose: Advanced image post-processing techniques which enhance soft-tissue contrast in CT have not been widely employed for RT planning or delivery guidance. The purpose of this work is to assess the soft-tissue contrast enhancement from non-linear contrast enhancing filters and its impact in RT. The contrast enhancement reduces patient alignment uncertainties. Methods: Non-linear contrast enhancing methods, such as Best Contrast (Siemens), amplify small differences in X-ray attenuation between two adjacent structure without significantly increasing noise. Best Contrast (BC) separates a CT into two frequency bands. The low frequency band is modified by a non-linear scaling function before recombination with themore » high frequency band. CT data collected using a CT-on-rails (Definition AS Open, Siemens) during daily CT-guided RT for 6 prostate cancer patients and an image quality phantom (The Phantom Laboratory) were analyzed. Images acquired with a standard protocol (120 kVp, 0.6 pitch, 18 mGy CTDIvol) were processed before comparison to the unaltered images. Contrast and noise were measured in the the phantom. Inter-observer variation was assessed by placing prostate contours on the 12 CT study sets, 6 enhanced and 6 unaltered, in a blinded study involving 8 observers. Results: The phantom data demonstrate that BC increased the contrast between the 1.0% supra-slice element and the background substrate by 46.5 HU while noise increased by only 2.3 HU. Thus the contrast to noise ratio increased from 1.28 to 6.71. Furthermore, the variation in centroid position of the prostate contours was decreased from 1.3±0.4 mm to 0.8±0.3 mm. Thus the CTV-to-PTV margin was reduced by 1.1 mm. The uncertainty in delineation of the prostate/rectum edge decreased by 0.5 mm. Conclusion: As demonstrated in phantom and patient scans the BC filter accentuates soft-tissue contrast. This enhancement leads to reduced inter-observer variation, which should improve RT planning and delivery. Supported by Siemens.« less
Statistical atlas based extrapolation of CT data
NASA Astrophysics Data System (ADS)
Chintalapani, Gouthami; Murphy, Ryan; Armiger, Robert S.; Lepisto, Jyri; Otake, Yoshito; Sugano, Nobuhiko; Taylor, Russell H.; Armand, Mehran
2010-02-01
We present a framework to estimate the missing anatomical details from a partial CT scan with the help of statistical shape models. The motivating application is periacetabular osteotomy (PAO), a technique for treating developmental hip dysplasia, an abnormal condition of the hip socket that, if untreated, may lead to osteoarthritis. The common goals of PAO are to reduce pain, joint subluxation and improve contact pressure distribution by increasing the coverage of the femoral head by the hip socket. While current diagnosis and planning is based on radiological measurements, because of significant structural variations in dysplastic hips, a computer-assisted geometrical and biomechanical planning based on CT data is desirable to help the surgeon achieve optimal joint realignments. Most of the patients undergoing PAO are young females, hence it is usually desirable to minimize the radiation dose by scanning only the joint portion of the hip anatomy. These partial scans, however, do not provide enough information for biomechanical analysis due to missing iliac region. A statistical shape model of full pelvis anatomy is constructed from a database of CT scans. The partial volume is first aligned with the statistical atlas using an iterative affine registration, followed by a deformable registration step and the missing information is inferred from the atlas. The atlas inferences are further enhanced by the use of X-ray images of the patient, which are very common in an osteotomy procedure. The proposed method is validated with a leave-one-out analysis method. Osteotomy cuts are simulated and the effect of atlas predicted models on the actual procedure is evaluated.
SU-F-I-32: Organ Doses from Pediatric Head CT Scan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, H; Liu, Q; Qiu, J
Purpose: To evaluate the organ doses of pediatric patients who undergoing head CT scan using Monte Carlo (MC) simulation and compare it with measurements in anthropomorphic child phantom.. Methods: A ten years old children voxel phantom was developed from CT images, the voxel size of the phantom was 2mm*2mm*2mm. Organ doses from head CT scan were simulated using MCNPX software, 180 detectors were placed in the voxel phantom to tally the doses of the represented tissues or organs. When performing the simulation, 120 kVp and 88 mA were selected as the scan parameters. The scan range covered from the topmore » of the head to the end of the chain, this protocol was used at CT simulator for radiotherapy. To validate the simulated results, organ doses were measured with radiophotoluminescence (RPL) detectors, placed in the 28 organs of the 10 years old CIRS ATOM phantom. Results: The organ doses results matched well between MC simulation and phantom measurements. The eyes dose was showed to be as expected the highest organ dose: 28.11 mGy by simulation and 27.34 mGy by measurement respectively. Doses for organs not included in the scan volume were much lower than those included in the scan volume, thymus doses were observed more than 10 mGy due the CT protocol for radiotherapy covered more body part than routine head CT scan. Conclusion: As the eyes are superficial organs, they may receive the highest radiation dose during the CT scan. Considering the relatively high radio sensitivity, using shielding material or organ based tube current modulation technique should be encouraged to reduce the eye radiation risks. Scan range was one of the most important factors that affects the organ doses during the CT scan. Use as short as reasonably possible scan range should be helpful to reduce the patient radiation dose. This work was supported by the National Natural Science Foundation of China(11475047)« less
[Performance evaluation of CT automatic exposure control on fast dual spiral scan].
Niwa, Shinji; Hara, Takanori; Kato, Hideki; Wada, Yoichi
2014-11-01
The performance of individual computed tomography automatic exposure control (CT-AEC) is very important for radiation dose reduction and image quality equalization in CT examinations. The purpose of this study was to evaluate the performance of CT-AEC in conventional pitch mode (Normal spiral) and fast dual spiral scan (Flash spiral) in a 128-slice dual-source CT scanner. To evaluate the response properties of CT-AEC in the 128-slice DSCT scanner, a chest phantom was placed on the patient table and was fixed at the center of the field of view (FOV). The phantom scan was performed using Normal spiral and Flash spiral scanning. We measured the effective tube current time product (Eff. mAs) of simulated organs in the chest phantom along the longitudinal (z) direction, and the dose dependence (distribution) of in-plane locations for the respective scan modes was also evaluated by using a 100-mm-long pencil-type ionization chamber. The dose length product (DLP) was evaluated using the value displayed on the console after scanning. It was revealed that the response properties of CT-AEC in Normal spiral scanning depend on the respective pitches and Flash spiral scanning is independent of the respective pitches. In-plane radiation dose of Flash spiral was lower than that of Normal spiral. The DLP values showed a difference of approximately 1.7 times at the maximum. The results of our experiments provide information for adjustments for appropriate scanning parameters using CT-AEC in a 128-slice DSCT scanner.
Automated lung volumetry from routine thoracic CT scans: how reliable is the result?
Haas, Matthias; Hamm, Bernd; Niehues, Stefan M
2014-05-01
Today, lung volumes can be easily calculated from chest computed tomography (CT) scans. Modern postprocessing workstations allow automated volume measurement of data sets acquired. However, there are challenges in the use of lung volume as an indicator of pulmonary disease when it is obtained from routine CT. Intra-individual variation and methodologic aspects have to be considered. Our goal was to assess the reliability of volumetric measurements in routine CT lung scans. Forty adult cancer patients whose lungs were unaffected by the disease underwent routine chest CT scans in 3-month intervals, resulting in a total number of 302 chest CT scans. Lung volume was calculated by automatic volumetry software. On average of 7.2 CT scans were successfully evaluable per patient (range 2-15). Intra-individual changes were assessed. In the set of patients investigated, lung volume was approximately normally distributed, with a mean of 5283 cm(3) (standard deviation = 947 cm(3), skewness = -0.34, and curtosis = 0.16). Between different scans in one and the same patient the median intra-individual standard deviation in lung volume was 853 cm(3) (16% of the mean lung volume). Automatic lung segmentation of routine chest CT scans allows a technically stable estimation of lung volume. However, substantial intra-individual variations have to be considered. A median intra-individual deviation of 16% in lung volume between different routine scans was found. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Maxfield, Mark W; Schuster, Kevin M; McGillicuddy, Edward A; Young, Calvin J; Ghita, Monica; Bokhari, S A Jamal; Oliva, Isabel B; Brink, James A; Davis, Kimberly A
2012-12-01
A recent study showed that computed tomographic (CT) scans contributed 93% of radiation exposure of 177 patients admitted to our Level I trauma center. Adaptive statistical iterative reconstruction (ASIR) is an algorithm that reduces the noise level in reconstructed images and therefore allows the use of less ionizing radiation during CT scans without significantly affecting image quality. ASIR was instituted on all CT scans performed on trauma patients in June 2009. Our objective was to determine if implementation of ASIR reduced radiation dose without compromising patient outcomes. We identified 300 patients activating the trauma system before and after the implementation of ASIR imaging. After applying inclusion criteria, 245 charts were reviewed. Baseline demographics, presenting characteristics, number of delayed diagnoses, and missed injuries were recorded. The postexamination volume CT dose index (CTDIvol) and dose-length product (DLP) reported by the scanner for CT scans of the chest, abdomen, and pelvis and CT scans of the brain and cervical spine were recorded. Subjective image quality was compared between the two groups. For CT scans of the chest, abdomen, and pelvis, the mean CTDIvol (17.1 mGy vs. 14.2 mGy; p < 0.001) and DLP (1,165 mGy·cm vs. 1,004 mGy·cm; p < 0.001) was lower for studies performed with ASIR. For CT scans of the brain and cervical spine, the mean CTDIvol (61.7 mGy vs. 49.6 mGy; p < 0.001) and DLP (1,327 mGy·cm vs. 1,067 mGy·cm; p < 0.001) was lower for studies performed with ASIR. There was no subjective difference in image quality between ASIR and non-ASIR scans. All CT scans were deemed of good or excellent image quality. There were no delayed diagnoses or missed injuries related to CT scanning identified in either group. Implementation of ASIR imaging for CT scans performed on trauma patients led to a nearly 20% reduction in ionizing radiation without compromising outcomes or image quality. Therapeutic study, level IV.
Maxfield, Mark W.; Schuster, Kevin M.; McGillicuddy, Edward A.; Young, Calvin J.; Ghita, Monica; Bokhari, S.A. Jamal; Oliva, Isabel B.; Brink, James A.; Davis, Kimberly A.
2013-01-01
BACKGROUND A recent study showed that computed tomographic (CT) scans contributed 93% of radiation exposure of 177 patients admitted to our Level I trauma center. Adaptive statistical iterative reconstruction (ASIR) is an algorithm that reduces the noise level in reconstructed images and therefore allows the use of less ionizing radiation during CT scans without significantly affecting image quality. ASIR was instituted on all CT scans performed on trauma patients in June 2009. Our objective was to determine if implementation of ASIR reduced radiation dose without compromising patient outcomes. METHODS We identified 300 patients activating the trauma system before and after the implementation of ASIR imaging. After applying inclusion criteria, 245 charts were reviewed. Baseline demographics, presenting characteristics, number of delayed diagnoses, and missed injuries were recorded. The postexamination volume CT dose index (CTDIvol) and dose-length product (DLP)reported by the scanner for CT scans of the chest, abdomen, and pelvis and CT scans of the brain and cervical spine were recorded. Subjective image quality was compared between the two groups. RESULTS For CT scans of the chest, abdomen, and pelvis, the mean CTDIvol(17.1 mGy vs. 14.2 mGy; p < 0.001) and DLP (1,165 mGy·cm vs. 1,004 mGy·cm; p < 0.001) was lower for studies performed with ASIR. For CT scans of the brain and cervical spine, the mean CTDIvol(61.7 mGy vs. 49.6 mGy; p < 0.001) and DLP (1,327 mGy·cm vs. 1,067 mGy·cm; p < 0.001) was lower for studies performed with ASIR. There was no subjective difference in image quality between ASIR and non-ASIR scans. All CT scans were deemed of good or excellent image quality. There were no delayed diagnoses or missed injuries related to CT scanning identified in either group. CONCLUSION Implementation of ASIR imaging for CT scans performed on trauma patients led to a nearly 20% reduction in ionizing radiation without compromising outcomes or image quality. PMID:23147183
Sato, Haruka; Okada, Fumito; Matsumoto, Shunro; Mori, Hiromu; Kashiwagi, Junji; Komatsu, Eiji; Maeda, Toru; Nishida, Haruto; Daa, Tsutomu; Ohtani, Satoshi; Umeki, Kenji; Ando, Masaru; Kadota, Junichi
2018-05-03
The aim of this study was to assess the CT findings that characterise haemoptysis in patients with chronic pulmonary aspergillosis (CPA). We retrospectively identified 120 consecutive patients with CPA (84 men and 36 women, 17-89 years of age, mean age 68.4 years) who had undergone a total of 829 CT examinations between January 2007 and February 2017. In the 11 patients who underwent surgical resection, CT images were compared with the pathological results. The scab-like sign was seen on 142 of the 829 CT scans, specifically, in 87 of the 90 CT scans for haemoptysis and in 55 of the 739 CT scans obtained during therapy evaluation. In 48 of those 55 patients, haemoptysis occurred within 55 days (mean 12.0 days) after the CT scan. In the 687 CT scans with no scab-like sign, there were only three instances of subsequent haemoptysis in the respective patients over the following 6 months. Patients with and without scab-like sign differed significantly in the frequency of haemoptysis occurring after a CT scan (p<0.0001). Pathologically, the scab-like sign corresponded to a fibrinopurulent mass or blood crust. The scab-like sign should be considered as a CT finding indicative of haemoptysis. • Haemoptysis is commonly found in patients with CPA. • A CT finding indicative of haemoptysis in CPA patients is described. • Scab-like sign may identify CPA patients at higher risk of haemoptysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bergin, C.J.; Bell, D.Y.; Coblentz, C.L.
1989-06-01
The appearances of the lungs on radiographs and computed tomographic (CT) scans were correlated with degree of uptake on gallium scans and results of pulmonary function tests (PFTs) in 27 patients with sarcoidosis. CT scans were evaluated both qualitatively and quantitatively. Patients were divided into five categories on the basis of the pattern of abnormality at CT: 1 = normal (n = 4); 2 = segmental air-space disease (n = 4); 3 = spherical (alveolar) masslike opacities (n = 4); 4 = multiple, discrete, small nodules (n = 6); and 5 = distortion of parenchymal structures (fibrotic end-stage sarcoidosis) (nmore » = 9). The percentage of the volume judged to be abnormal (CT grade) was correlated with PFT results for each CT and radiographic category. CT grades were also correlated with gallium scanning results and percentage of lymphocytes recovered from bronchoalveolar lavage (BAL). Patients in CT categories 1 and 2 had normal lung function, those in category 3 had mild functional impairment, and those in categories 4 and 5 showed moderate to severe dysfunction. The overall CT grade correlated well with PFT results expressed as a percentage of the predicted value. In five patients, CT scans showed extensive parenchymal disease not seen on radiographs. CT grades did not correlate with the results of gallium scanning or BAL lymphocytes. The authors conclude that patterns of parenchymal sarcoidosis seen at CT correlate with the PFT results and can be used to indicate respiratory impairment.« less
Optimization of dose and image quality in adult and pediatric computed tomography scans
NASA Astrophysics Data System (ADS)
Chang, Kwo-Ping; Hsu, Tzu-Kun; Lin, Wei-Ting; Hsu, Wen-Lin
2017-11-01
Exploration to maximize CT image and reduce radiation dose was conducted while controlling for multiple factors. The kVp, mAs, and iteration reconstruction (IR), affect the CT image quality and radiation dose absorbed. The optimal protocols (kVp, mAs, IR) are derived by figure of merit (FOM) based on CT image quality (CNR) and CT dose index (CTDIvol). CT image quality metrics such as CT number accuracy, SNR, low contrast materials' CNR and line pair resolution were also analyzed as auxiliary assessments. CT protocols were carried out with an ACR accreditation phantom and a five-year-old pediatric head phantom. The threshold values of the adult CT scan parameters, 100 kVp and 150 mAs, were determined from the CT number test and line pairs in ACR phantom module 1and module 4 respectively. The findings of this study suggest that the optimal scanning parameters for adults be set at 100 kVp and 150-250 mAs. However, for improved low- contrast resolution, 120 kVp and 150-250 mAs are optimal. Optimal settings for pediatric head CT scan were 80 kVp/50 mAs, for maxillary sinus and brain stem, while 80 kVp /300 mAs for temporal bone. SNR is not reliable as the independent image parameter nor the metric for determining optimal CT scan parameters. The iteration reconstruction (IR) approach is strongly recommended for both adult and pediatric CT scanning as it markedly improves image quality without affecting radiation dose.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yadava, G; Imai, Y; Hsieh, J
2014-06-15
Purpose: Quantitative accuracy of Iodine Hounsfield Unit (HU) in conventional single-kVp scanning is susceptible to beam-hardening effect. Dual-energy CT has unique capabilities of quantification using monochromatic CT images, but this scanning mode requires the availability of the state-of-the-art CT scanner and, therefore, is limited in routine clinical practice. Purpose of this work was to develop a beam-hardening-correction (BHC) for single-kVp CT that can linearize Iodine projections at any nominal energy, apply this approach to study Iodine response with respect to keV, and compare with dual-energy based monochromatic images obtained from material-decomposition using 80kVp and 140kVp. Methods: Tissue characterization phantoms (Gammexmore » Inc.), containing solid-Iodine inserts of different concentrations, were scanned using GE multi-slice CT scanner at 80, 100, 120, and 140 kVp. A model-based BHC algorithm was developed where Iodine was estimated using re-projection of image volume and corrected through an iterative process. In the correction, the re-projected Iodine was linearized using a polynomial mapping between monochromatic path-lengths at various nominal energies (40 to 140 keV) and physically modeled polychromatic path-lengths. The beam-hardening-corrected 80kVp and 140kVp images (linearized approximately at effective energy of the beam) were used for dual-energy material-decomposition in Water-Iodine basis-pair followed by generation of monochromatic images. Characterization of Iodine HU and noise in the images obtained from singlekVp with BHC at various nominal keV, and corresponding dual-energy monochromatic images, was carried out. Results: Iodine HU vs. keV response from single-kVp with BHC and dual-energy monochromatic images were found to be very similar, indicating that single-kVp data may be used to create material specific monochromatic equivalent using modelbased projection linearization. Conclusion: This approach may enable quantification of Iodine contrast enhancement and potential reduction in injected contrast without using dual-energy scanning. However, in general, dual-energy scanning has unique value in material characterization and quantification, and its value cannot be discounted. GE Healthcare Employee.« less
Henninger, B.; Putzer, D.; Kendler, D.; Uprimny, C.; Virgolini, I.; Gunsilius, E.; Bale, R.
2012-01-01
Aim. The purpose of this study was to evaluate the accuracy of 2-deoxy-2-[fluorine-18]fluoro-D-glucose (FDG) positron emission tomography (PET), computed tomography (CT), and software-based image fusion of both modalities in the imaging of non-Hodgkin's lymphoma (NHL) and Hodgkin's disease (HD). Methods. 77 patients with NHL (n = 58) or HD (n = 19) underwent a FDG PET scan, a contrast-enhanced CT, and a subsequent digital image fusion during initial staging or followup. 109 examinations of each modality were evaluated and compared to each other. Conventional staging procedures, other imaging techniques, laboratory screening, and follow-up data constituted the reference standard for comparison with image fusion. Sensitivity and specificity were calculated for CT and PET separately. Results. Sensitivity and specificity for detecting malignant lymphoma were 90% and 76% for CT and 94% and 91% for PET, respectively. A lymph node region-based analysis (comprising 14 defined anatomical regions) revealed a sensitivity of 81% and a specificity of 97% for CT and 96% and 99% for FDG PET, respectively. Only three of 109 image fusion findings needed further evaluation (false positive). Conclusion. Digital fusion of PET and CT improves the accuracy of staging, restaging, and therapy monitoring in patients with malignant lymphoma and may reduce the need for invasive diagnostic procedures. PMID:22654631
Shaffiq Said Rahmat, Said Mohd; Md Saad, Wan Mazlina
2013-01-01
The study aimed to investigate the effects of different tube potentials and concentrations of iodinated contrast media (CM) on the image enhancement, contrast-to-noise ratio (CNR) and noise in micro-computed tomography (µCT) images. A phantom containing of five polyethylene tube was filled with 2 mL of deionized water and iodinated CM (Omnipaque 300 mgI/mL) at four different concentrations: 5, 10, 15, and 20 mol/L, respectively. The phantom was scanned with a µCT machine (SkyScan 1176) using various tube potentials: 40, 50, 60, 70, 80, and 90 kVp, a fixed tube current; 100 µA, and filtration of 0.2 mm aluminum (Al). The percentage difference of image enhancement, CNR and noise of all images, acquired at different kVps and concentrations, were calculated. The image enhancement, CNR and noise curves with respect to tube potential and concentration were plotted and analysed. The highest image enhancement was found at the lowest tube potential of 40 kVp. At this kVp setting, the percentage difference of image enhancement [Hounsfield Unit (HU) of 20 mol/L iodine concentration over HU of deionized water] was 43%. By increasing the tube potential, it resulted with the reduction of HU, where only 17.5% different were noticed for 90 kVp. Across all iodine concentrations (5-20 M), CNR peaked at 80 kVp and then these values showed a slight decreasing pattern, which might be due insufficient tube current compensation. The percentage difference of image noise obtained at 40 and 90 kVp was 72.4%. Lower tube potential setting results in higher image enhancement (HU) in conjunction with increasing concentration of iodinated CM. Overall, the tube potential increment will substantially improve CNR and reduce image noise. PMID:24273743
Kim, Sangroh; Yoshizumi, Terry T; Yin, Fang-Fang; Chetty, Indrin J
2013-04-21
Currently, the BEAMnrc/EGSnrc Monte Carlo (MC) system does not provide a spiral CT source model for the simulation of spiral CT scanning. We developed and validated a spiral CT phase-space source model in the BEAMnrc/EGSnrc system. The spiral phase-space source model was implemented in the DOSXYZnrc user code of the BEAMnrc/EGSnrc system by analyzing the geometry of spiral CT scan-scan range, initial angle, rotational direction, pitch, slice thickness, etc. Table movement was simulated by changing the coordinates of the isocenter as a function of beam angles. Some parameters such as pitch, slice thickness and translation per rotation were also incorporated into the model to make the new phase-space source model, designed specifically for spiral CT scan simulations. The source model was hard-coded by modifying the 'ISource = 8: Phase-Space Source Incident from Multiple Directions' in the srcxyznrc.mortran and dosxyznrc.mortran files in the DOSXYZnrc user code. In order to verify the implementation, spiral CT scans were simulated in a CT dose index phantom using the validated x-ray tube model of a commercial CT simulator for both the original multi-direction source (ISOURCE = 8) and the new phase-space source model in the DOSXYZnrc system. Then the acquired 2D and 3D dose distributions were analyzed with respect to the input parameters for various pitch values. In addition, surface-dose profiles were also measured for a patient CT scan protocol using radiochromic film and were compared with the MC simulations. The new phase-space source model was found to simulate the spiral CT scanning in a single simulation run accurately. It also produced the equivalent dose distribution of the ISOURCE = 8 model for the same CT scan parameters. The MC-simulated surface profiles were well matched to the film measurement overall within 10%. The new spiral CT phase-space source model was implemented in the BEAMnrc/EGSnrc system. This work will be beneficial in estimating the spiral CT scan dose in the BEAMnrc/EGSnrc system.
Hidaka, Dai; Koshizuka, Hiroaki; Hiyama, Junichiro; Nakatsubo, Seita; Ikeda, Koutarou; Hayashi, Akihiro; Fujii, Akiko; Sawamoto, Ryouko; Misumi, Yukihiro; Miyagawa, Yousuke
2009-03-01
A 57-year-old man complaining of right shoulder pain was admitted. Chest enhanced CT scanning showed a mass shadow in the right upper lobe with chest wall invasion. The laboratory data on admission showed marked leukocytosis. A CT-guided lung biopsy was performed, and a histological examination of the biopsy specimen showed a spindle cell type pleomorphic carcinoma. Immunohistochemistry staining using an anti-granulocyte colony-stimulating factor (G-CSF) monoclonal antibody demonstrated many tumor cells containing G-CSF as well as an increased level of serum G-CSF. The diagnosis was determined to be lung cancer producing G-CSF. FDG-PET scanning showed a significantly high uptake in the right upper field and the bones throughout the body. After chemoradiation therapy, the patient underwent a right upper lobectomy with a chest wall resection. Since then, the leukocytosis and the high level of serum G-CSF normalized and the high uptake in the bones disappeared in the FDG-PET scan.
Metintas, Muzaffer; Ak, Guntulu; Dundar, Emine; Yildirim, Huseyin; Ozkan, Ragip; Kurt, Emel; Erginel, Sinan; Alatas, Fusun; Metintas, Selma
2010-06-01
In cases of pleural effusion, tissue samples can be obtained through Abrams needle pleural biopsy (ANPB), thoracoscopy, or cutting-needle pleural biopsy under the guidance of CT scan (CT-CNPB) for histopathologic analysis. This study aimed to compare the diagnostic efficiency and reliability of ANPB under CT scan guidance (CT-ANPB) with that of medical thoracoscopy in patients with pleural effusion. Between January 2006 and January 2008, 124 patients with exudative pleural effusion that could not be diagnosed by cytologic analysis were included in the study. All patients were randomized after the CT scan was performed. Patients either underwent CT-ANPB or thoracoscopy. The two groups were compared in terms of diagnostic sensitivity and complications associated with the methods used. Of the 124 patients, malignant mesothelioma was diagnosed in 33, metastatic pleural disease in 47, benign pleural disease in 42, and two were of indeterminate origin. In the CT-ANPB group, the diagnostic sensitivity was 87.5%, as compared with 94.1% in the thoracoscopy group; the difference was not statistically significant (P = .252). No difference was identified between the sensitivities of the two methods based on the cause, the CT scan findings, and the degree of pleural thickening. Complication rates were low and acceptable. We recommend the use of CT-ANPB as the primary method of diagnosis in patients with pleural thickening or lesions observed by CT scan. In patients with only pleural fluid appearance on CT scan and in those who may have benign pleural pathologies other than TB, the primary method of diagnosis should be medical thoracoscopy. clinicaltrials.gov; Identifier: NCT00720954.
Uchida, Masafumi
2014-04-01
A few years ago it could take several hours to complete a 3D image using a 3D workstation. Thanks to advances in computer science, obtaining results of interest now requires only a few minutes. Many recent 3D workstations or multimedia computers are equipped with onboard 3D virtual patient modeling software, which enables patient-specific preoperative assessment and virtual planning, navigation, and tool positioning. Although medical 3D imaging can now be conducted using various modalities, including computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), and ultrasonography (US) among others, the highest quality images are obtained using CT data, and CT images are now the most commonly used source of data for 3D simulation and navigation image. If the 2D source image is bad, no amount of 3D image manipulation in software will provide a quality 3D image. In this exhibition, the recent advances in CT imaging technique and 3D visualization of the hepatobiliary and pancreatic abnormalities are featured, including scan and image reconstruction technique, contrast-enhanced techniques, new application of advanced CT scan techniques, and new virtual reality simulation and navigation imaging. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
Strauss, Keith J
2014-10-01
The management of image quality and radiation dose during pediatric CT scanning is dependent on how well one manages the radiographic techniques as a function of the type of exam, type of CT scanner, and patient size. The CT scanner's display of expected CT dose index volume (CTDIvol) after the projection scan provides the operator with a powerful tool prior to the patient scan to identify and manage appropriate CT techniques, provided the department has established appropriate diagnostic reference levels (DRLs). This paper provides a step-by-step process that allows the development of DRLs as a function of type of exam, of actual patient size and of the individual radiation output of each CT scanner in a department. Abdomen, pelvis, thorax and head scans are addressed. Patient sizes from newborns to large adults are discussed. The method addresses every CT scanner regardless of vendor, model or vintage. We cover adjustments to techniques to manage the impact of iterative reconstruction and provide a method to handle all available voltages other than 120 kV. This level of management of CT techniques is necessary to properly monitor radiation dose and image quality during pediatric CT scans.
Avanesov, Maxim; Weinrich, Julius M; Kraus, Thomas; Derlin, Thorsten; Adam, Gerhard; Yamamura, Jin; Karul, Murat
2016-11-01
The purpose of the retrospective study was to evaluate the additional value of dual-phase multidetector computed tomography (MDCT) protocols over a single-phase protocol on initial MDCT in patients with acute pancreatitis using three CT-based pancreatitis severity scores with regard to radiation dose. In this retrospective, IRB approved study MDCT was performed in 102 consecutive patients (73 males; 55years, IQR48-64) with acute pancreatitis. Inclusion criteria were CT findings of interstitial edematous pancreatitis (IP) or necrotizing pancreatitis (NP) and a contrast-enhanced dual-phase (arterial phase and portal-venous phase) abdominal CT performed at ≥72h after onset of symptoms. The severity of pancreatic and extrapancreatic changes was independently assessed by 2 observers using 3 validated CT-based scoring systems (CTSI, mCTSI, EPIC). All scores were applied to arterial phase and portal venous phase scans and compared to score results of portal venous phase scans, assessed ≥14days after initial evaluation. For effective dose estimation, volume CT dose index (CTDIvol) and dose length product (DLP) were recorded in all examinations. In neither of the CT severity scores a significant difference was observed after application of a dual-phase protocol compared with a single-phase protocol (IP: CTSI: 2.7 vs. 2.5, p=0.25; mCTSI: 4.0 vs. 4.0, p=0.10; EPIC: 2.0 vs. 2.0, p=0.41; NP: CTSI: 8.0 vs. 7.0, p=0.64; mCTSI: 8.0 vs. 8.0, p=0.10; EPIC: 3.0 vs. 3.0, p=0.06). The application of a single-phase CT protocol was associated with a median effective dose reduction of 36% (mean dose reduction 31%) compared to a dual-phase CT scan. An initial dual-phase abdominal CT after ≥72h after onset of symptoms of acute pancreatitis was not superior to a single-phase protocol for evaluation of the severity of pancreatic and extrapancreatic changes. However, the effective radiation dose may be reduced by 36% using a single-phase protocol. Copyright © 2016. Published by Elsevier Ireland Ltd.
Arab, Ala Faisal; Ahmed, Anwar E; Hussein, Mohamed Ahmed; Khankan, Azzam A; Alokaili, Riyadh Nasser
2015-01-01
Background Investigation of unjustified computed tomography (CT) scan in patients with minor head injury is lacking in Saudi Arabia. The purpose of the study was to evaluate the compliance and effectiveness of the Canadian computed tomography head rule (CCHR) in our emergency department (ED) and trauma centre and also to reduce the number of unjustified CT studies of the head in the centre. Methods A retrospective study of 368 ED patients with minor head injury was conducted. Patients who underwent CT scan between July 2010 and June 2011were selected from the ED head trauma registry by systematic randomisation. The CCHR was retrospectively applied on the patients’ charts to calculate the prevalence of unjustified head CT scans. A separate survey was conducted to evaluate three emergency physicians’ level of awareness about the CCHR and their ability to determine the necessity of CT scans with various clinical scenarios of head injury. Results The prevalence of unjustified CT scans as per the CCHR was 61.8% (95% confidence interval (CI) 56.5–66.9%). Approximately 5% of the sample had positive CT findings with 95% CI 2.9–7.6%. The CCHR correctly identified 12 cases with positive CT findings with 66.67% sensitivity. Only 24 (6.7%) had Glasgow coma scale scores less than 15 (13/14). The Glasgow coma scale correctly identified only two cases with positive CT findings with 11.11% sensitivity. The percentage of skull fracture (0.9% vs 5%, P = 0.030) was significantly lower in patients with unjustified CT scans than in patients with clinically justified CT scans. There was fair to substantial agreement between the ED physicians and the CCHR (κ = 35–61%). Two ED physicians identified all cases of justified CT scan with 100% sensitivity (95% CI 71.51–100%). Conclusion The level of education regarding the CCHR was found to be optimal among emergency physicians using a case-based scenario survey. The CCHR was found to have a poor compliance potential in the busy ED of our trauma centre and the prevalence of unjustified cranial CT scans remained high. PMID:26471399
NASA Astrophysics Data System (ADS)
Chen, Buxin; Zhang, Zheng; Sidky, Emil Y.; Xia, Dan; Pan, Xiaochuan
2017-11-01
Optimization-based algorithms for image reconstruction in multispectral (or photon-counting) computed tomography (MCT) remains a topic of active research. The challenge of optimization-based image reconstruction in MCT stems from the inherently non-linear data model that can lead to a non-convex optimization program for which no mathematically exact solver seems to exist for achieving globally optimal solutions. In this work, based upon a non-linear data model, we design a non-convex optimization program, derive its first-order-optimality conditions, and propose an algorithm to solve the program for image reconstruction in MCT. In addition to consideration of image reconstruction for the standard scan configuration, the emphasis is on investigating the algorithm’s potential for enabling non-standard scan configurations with no or minimum hardware modification to existing CT systems, which has potential practical implications for lowered hardware cost, enhanced scanning flexibility, and reduced imaging dose/time in MCT. Numerical studies are carried out for verification of the algorithm and its implementation, and for a preliminary demonstration and characterization of the algorithm in reconstructing images and in enabling non-standard configurations with varying scanning angular range and/or x-ray illumination coverage in MCT.
Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience
Pourmorteza, Amir; Symons, Rolf; Sandfort, Veit; Mallek, Marissa; Fuld, Matthew K.; Henderson, Gregory; Jones, Elizabeth C.; Malayeri, Ashkan A.; Folio, Les R.
2016-01-01
Purpose To evaluate the performance of a prototype photon-counting detector (PCD) computed tomography (CT) system for abdominal CT in humans and to compare the results with a conventional energy-integrating detector (EID). Materials and Methods The study was HIPAA-compliant and institutional review board–approved with informed consent. Fifteen asymptomatic volunteers (seven men; mean age, 58.2 years ± 9.8 [standard deviation]) were prospectively enrolled between September 2 and November 13, 2015. Radiation dose–matched delayed contrast agent–enhanced spiral and axial abdominal EID and PCD scans were acquired. Spiral images were scored for image quality (Wilcoxon signed-rank test) in five regions of interest by three radiologists blinded to the detector system, and the axial scans were used to assess Hounsfield unit accuracy in seven regions of interest (paired t test). Intraclass correlation coefficient (ICC) was used to assess reproducibility. PCD images were also used to calculate iodine concentration maps. Spatial resolution, noise-power spectrum, and Hounsfield unit accuracy of the systems were estimated by using a CT phantom. Results In both systems, scores were similar for image quality (median score, 4; P = .19), noise (median score, 3; P = .30), and artifact (median score, 1; P = .17), with good interrater agreement (image quality, noise, and artifact ICC: 0.84, 0.88, and 0.74, respectively). Hounsfield unit values, spatial resolution, and noise-power spectrum were also similar with the exception of mean Hounsfield unit value in the spinal canal, which was lower in the PCD than the EID images because of beam hardening (20 HU vs 36.5 HU; P < .001). Contrast-to-noise ratio of enhanced kidney tissue was improved with PCD iodine mapping compared with EID (5.2 ± 1.3 vs 4.0 ± 1.3; P < .001). Conclusion The performance of PCD showed no statistically significant difference compared with EID when the abdomen was evaluated in a conventional scan mode. PCD provides spectral information, which may be used for material decomposition. © RSNA, 2016 PMID:26840654
Uosyte, Raimonda; Shaw, Darren J; Gunn-Moore, Danielle A; Fraga-Manteiga, Eduardo; Schwarz, Tobias
2015-01-01
Turbinate destruction is an important diagnostic criterion in canine and feline nasal computed tomography (CT). However decreased turbinate visibility may also be caused by technical CT settings and nasal fluid. The purpose of this experimental, crossover study was to determine whether fluid reduces conspicuity of canine and feline nasal turbinates in CT and if so, whether CT settings can maximize conspicuity. Three canine and three feline cadaver heads were used. Nasal slabs were CT-scanned before and after submerging them in a water bath; using sequential, helical, and ultrahigh resolution modes; with images in low, medium, and high frequency image reconstruction kernels; and with application of additional posterior fossa optimization and high contrast enhancing filters. Visible turbinate length was measured by a single observer using manual tracing. Nasal density heterogeneity was measured using the standard deviation (SD) of mean nasal density from a region of interest in each nasal cavity. Linear mixed-effect models using the R package ‘nlme’, multivariable models and standard post hoc Tukey pair-wise comparisons were performed to investigate the effect of several variables (nasal content, scanning mode, image reconstruction kernel, application of post reconstruction filters) on measured visible total turbinate length and SD of mean nasal density. All canine and feline water-filled nasal slabs showed significantly decreased visibility of nasal turbinates (P < 0.001). High frequency kernels provided the best turbinate visibility and highest SD of aerated nasal slabs, whereas medium frequency kernels were optimal for water-filled nasal slabs. Scanning mode and filter application had no effect on turbinate visibility. PMID:25867935
Novotny, Vojtech; Nacu, Aliona; Kvistad, Christopher E; Fromm, Annette; Neckelmann, Gesche F; Khanevski, Andrej N; Tobro, Haakon; Waje-Andreassen, Ulrike; Naess, Halvor; Thomassen, Lars; Logallo, Nicola
2017-11-08
Contrast-enhanced sonothrombolysis (CEST) seems to be a safe and promising treatment in acute ischemic stroke. It remains unknown if temporal bone features may influence the efficacy of CEST. We investigated the association between different temporal bone features on admission computed tomography (CT) scan and the outcome in acute ischemic stroke patients included in the randomized Norwegian Sonothrombolysis in Acute Stroke Study (NOR-SASS). Patients diagnosed as stroke mimics and those with infratentorial stroke or with incorrect insonation were excluded. We retrospectively assessed temporal bone heterogeneity (presence of diploë), diploë ratio, thickness, and density on admission CT scans. National institute of Health Stroke Scale (NIHSS) at 24 h and modified Rankin Scale (mRS) at 3 months were correlated with CT findings both in CEST and sham CEST patients. A total of 99 patients were included of which 52 were assigned to CEST and 47 to sham CEST. Approximately 20% patients had a heterogeneous temporal bone in both the CEST and sham CEST group. All temporal bone CT features studied were associated with female sex. In the CEST group, temporal bone heterogeneity (p = 0.006) and higher temporal bone diploë ratio (p = 0.002) were associated with higher NIHSS at 24 h. There was no association between temporal bone features and mRS at 3 months. Approximately 20% of acute ischemic stroke patients have heterogeneous temporal bone and may be resistant to standard 2-MHz transcranial Doppler ultrasound treatment. Sonothrombolysis resistance may easily be predicted by admission CT for better selection.
Strauss, Christiane; Mal, Frederic; Perniceni, Thierry; Bouzar, Nadia; Lenoir, Stephane; Gayet, Brice; Palau, Robert
2010-04-01
Water-soluble contrast swallow (CS) is usually performed before refeeding for anastomosis assessment after esophagectomy with intrathoracic anastomosis but the sensitivity of CS is low. Another diagnostic approach is based on analysis of computed tomography (CT) scan with oral contrast and of CT mediastinal air images. We undertook to compare them prospectively. Ninety-seven patients with an esophageal carcinoma operated by intrathoracic anastomosis were included prospectively in a study based on a CT scan at postoperative day 3 (without oral and intravenous contrast) and CT scan and CS at day 7. CT scan analysis consisted of assessing contrast and air leakage. In case of doubt, an endoscopy was done. A diagnosis of anastomotic leak was made in 13 patients (13.4%), in 2 cases before day 7 and in 3 beyond day 7. At day 3, 94 CT scans were performed, but the diagnostic value was poor. In 95 patients with both CS and CT scan at day 7, CS disclosed a leak in 5 of 11, and CT scan was abnormal in 8 of 11. Leakage of contrast and/or presence of mediastinal gas had the best negative predictive value (95.8%). Endoscopy was done in 16 patients with only mediastinal gas at day 7 CT scan. It disclosed a normal anastomosis in 11, fibrin deposits in 4, and a leak in 1. In comparison with CS only, CT at day 7 improves the sensitivity and negative predictive value for diagnosing an anastomotic leak. In case of doubt endoscopy is advisable. This approach provides an accurate assessment of the anastomosis before refeeding.
Montes, Carlos; Tamayo, Pilar; Hernandez, Jorge; Gomez-Caminero, Felipe; García, Sofia; Martín, Carlos; Rosero, Angela
2013-08-01
Hybrid imaging, such as SPECT/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose.
Dewailly, Marion; Rémy-Jardin, Martine; Duhamel, Alain; Faivre, Jean-Baptiste; Pontana, François; Deken, Valérie; Bakai, Anne-Marie; Remy, Jacques
2010-01-01
To evaluate the performance of a computer-aided detection (CAD) system for diagnosing peripheral acute pulmonary embolism (PE) with a 64-slice multi-detector row computed tomography (CT). Two radiologists investigated the accuracy of a software aimed at detecting peripheral clots (PECAD prototype, version 7; Siemens Medical Systems, Forchheim, Germany) by applying this tool for the analysis of the pulmonary arterial bed of 74 CT angiograms obtained with 64-slice dual-source CT (Definition; Siemens Medical Systems). These cases were retrospectively selected from a database of CT studies performed on the same CT unit, with a similar collimation (64 x 0.6 mm) and similar injection protocols. Patient selection was based on a variety of (1) scanning conditions, namely, nongated (n = 30), electrocardiography-gated (n = 30), and dual-energy CT angiograms (n = 14), and (2) image quality (IQ), namely, scans of excellent IQ (n = 53) and lower IQ due to lower levels of arterial enhancement and/or presence of noise (n = 21). The standard of truth was based on the 2 radiologists' consensus reading and the results of CAD. The software detected 80 of 93 peripheral clots present in the 21 patients (42 segmental and 38 subsegmental clots). The overall sensitivity (95% confidence interval) of the CAD tool was 86% (77%-92%) for detecting peripheral clots, 78% (64.5%-88%) at the segmental level and 97% (85.5%-99.9%) at the subsegmental level. Assuming normal vascular anatomy with 20 segmental and 40 subsegmental arteries, overall specificity and positive and negative predictive values (95% confidence interval) of the software were 91.8% (91%-92.6%), 18.4% (15%-22.4%), and 99.7% (99.5%-99.8%), respectively. A mean of 5.4 false positives was found per patient (total, 354 false positives), mainly linked to the presence of perivascular connective tissue (n = 119; 34%) and perivascular airspace consolidation (n = 97; 27%). The sensitivities (95% confidence interval) for the CAD tool were 91% (69.8%-99.3%) for dual-energy, 87% (59.3%-93.2%) for electrocardiography-gated, and 87% (73.5%-95.3%) for nongated scans (P > 0.05). No significant difference was found in the sensitivity of the CAD software when comparing the scans according to the scanning conditions and image quality. The evaluated CAD software has a good sensitivity in detecting peripheral PE, which is not influenced by the scanning conditions or the overall image quality.
Enhanced yield of chromosome aberrations after CT examinations in paediatric patients.
Stephan, G; Schneider, K; Panzer, W; Walsh, L; Oestreicher, U
2007-05-01
To determine whether computed tomography (CT) could enhance the chromosome aberration yields in paediatric patients. Blood samples were taken before and after CT scans from 10 children for whom the medical justifications for CT examinations were accidental injuries and not diseases as investigated in earlier studies. Chromosome analysis was carried out in lymphocytes by fluorescence plus Giemsa (FPG) staining exclusively in metaphases of the first cell cycle in vitro. The mean blood dose of the 10 children was about 12.9 mGy which was determined by a newly developed dose estimation. Based on more than 20,000 analyzed cells it was found that after CT examination the frequencies of dicentrics (dic) and excess acentric fragments (ace) in lymphocytes were significantly increased. By subdividing the children into two age groups, those with an age from 0.4 years to 9 years and from 10 - 15 years, it became obvious that the observed increase in chromosome aberrations was mainly contributed by the younger age group. In this group the frequency of dicentrics was significantly increased whereas in the older group the observed increase was not significant. Our results demonstrate that CT examinations enhance the dicentrics yields in peripheral lymphocytes of children aged up to 15 years. Since in particular significantly increased dicentric yields could be observed in children with an age from 0.4 - 9 years, it can be assumed that children younger than 10 years may be more radiation sensitive than older subjects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veiga, Catarina; Janssens, Guillaume; Teng, Ching-Ling
2016-05-01
Purpose: An adaptive proton therapy workflow using cone beam computed tomography (CBCT) is proposed. It consists of an online evaluation of a fast range-corrected dose distribution based on a virtual CT (vCT) scan. This can be followed by more accurate offline dose recalculation on the vCT scan, which can trigger a rescan CT (rCT) for replanning. Methods and Materials: The workflow was tested retrospectively for 20 consecutive lung cancer patients. A diffeomorphic Morphon algorithm was used to generate the lung vCT by deforming the average planning CT onto the CBCT scan. An additional correction step was applied to account formore » anatomic modifications that cannot be modeled by deformation alone. A set of clinical indicators for replanning were generated according to the water equivalent thickness (WET) and dose statistics and compared with those obtained on the rCT scan. The fast dose approximation consisted of warping the initial planned dose onto the vCT scan according to the changes in WET. The potential under- and over-ranges were assessed as a variation in WET at the target's distal surface. Results: The range-corrected dose from the vCT scan reproduced clinical indicators similar to those of the rCT scan. The workflow performed well under different clinical scenarios, including atelectasis, lung reinflation, and different types of tumor response. Between the vCT and rCT scans, we found a difference in the measured 95% percentile of the over-range distribution of 3.4 ± 2.7 mm. The limitations of the technique consisted of inherent uncertainties in deformable registration and the drawbacks of CBCT imaging. The correction step was adequate when gross errors occurred but could not recover subtle anatomic or density changes in tumors with complex topology. Conclusions: A proton therapy workflow based on CBCT provided clinical indicators similar to those using rCT for patients with lung cancer with considerable anatomic changes.« less
CT liver volumetry using geodesic active contour segmentation with a level-set algorithm
NASA Astrophysics Data System (ADS)
Suzuki, Kenji; Epstein, Mark L.; Kohlbrenner, Ryan; Obajuluwa, Ademola; Xu, Jianwu; Hori, Masatoshi; Baron, Richard
2010-03-01
Automatic liver segmentation on CT images is challenging because the liver often abuts other organs of a similar density. Our purpose was to develop an accurate automated liver segmentation scheme for measuring liver volumes. We developed an automated volumetry scheme for the liver in CT based on a 5 step schema. First, an anisotropic smoothing filter was applied to portal-venous phase CT images to remove noise while preserving the liver structure, followed by an edge enhancer to enhance the liver boundary. By using the boundary-enhanced image as a speed function, a fastmarching algorithm generated an initial surface that roughly estimated the liver shape. A geodesic-active-contour segmentation algorithm coupled with level-set contour-evolution refined the initial surface so as to more precisely fit the liver boundary. The liver volume was calculated based on the refined liver surface. Hepatic CT scans of eighteen prospective liver donors were obtained under a liver transplant protocol with a multi-detector CT system. Automated liver volumes obtained were compared with those manually traced by a radiologist, used as "gold standard." The mean liver volume obtained with our scheme was 1,520 cc, whereas the mean manual volume was 1,486 cc, with the mean absolute difference of 104 cc (7.0%). CT liver volumetrics based on an automated scheme agreed excellently with "goldstandard" manual volumetrics (intra-class correlation coefficient was 0.95) with no statistically significant difference (p(F<=f)=0.32), and required substantially less completion time. Our automated scheme provides an efficient and accurate way of measuring liver volumes.
Pulmonary Mucinous Cystadenocarcinoma: Report a Case and Review of CT Findings
Choi, Youn Ah; Han, Joungho; Choi, Joon Young; Kim, Jhingook; Kwon, O Jung; Lee, Kyung Soo
2013-01-01
A pulmonary mucinous cystadenocarcinoma is an extremely rare tumor that is considered to be a cystic variant of mucin-producing lung adenocarcinoma. We present a case of pulmonary mucinous cystadenocarcinoma in a 54-year-old woman. Chest CT scans showed a 4.3-cm-sized, lobulated, well-defined, and homogeneous mass in the right middle lobe with peripheral stippled calcifications that demonstrated low-attenuation with no enhancement after contrast administration; 18F-fluorodeoxyglucose (FDG) PET/CT demonstrated mild heterogeneous FDG uptake. The mass was diagnosed as adenocarcinoma with mucin production by transbronchial lung biopsy. Right middle lobectomy was performed, and the pathologic examination disclosed a pulmonary mucinous cystadenocarcinoma. PMID:23483761
Das, Anupam; Yadav, C S; Gamanagatti, Shivanand; Pandey, R M; Mittal, Ravi
2018-06-13
The outcome of single-bundle anterior cruciate ligament (ACL) reconstruction depends largely on the anatomic placement of bone tunnel. The lateral intercondylar ridge (LIR) and bifurcate ridge (BR) are useful bony landmarks for femoral tunnel placement. The purpose of our study was to compare the bony landmarks of ACL footprint on femur by three-dimensional computed tomography (3D CT) scan and arthroscopy in chronic ACL-deficient knees. Fifty patients above 18 years of age who were diagnosed of having ACL tear were selected for the study. All the cases were more than 6 months old since the injury. Preoperative 3D CT scan of the affected knee was obtained for each of them. They underwent single-bundle anatomic ACL reconstruction. Measurements were done on the preoperative 3D CT and arthroscopy to quantify the position of the LIR and BR. The proximodistal distance of lateral femoral condyle was 21.41+/-2.5 mm on CT scan and 22.02+/-2.02 mm on arthroscopy. On preoperative 3D CT scan, the midpoint of the LIR was found to be located at a mean distance of 11.17±2.11 mm from the proximal margin of the lateral femoral condyle. On arthroscopy, it was at 10.18+/-1.52 mm from the proximal margin the lateral femoral condyle. The "bifurcate ridge"(BR) was not visible in any of the cases during arthroscopy or CT scan. We concluded that LIR is an easily identifiable bony landmark on arthroscopy in all cases. It can also be identified on CT scans. BR is not identified both on arthroscopy and CT scans in chronic ACL tears. The arthroscopic measurements of bony landmarks are quite close to those of CT scan. Midpoint of LIR is at 52.185% of the proximodistal distance on CT scan evaluation and it is at 46.21% on arthroscopic evaluation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Tokihiro, E-mail: toyamamoto@ucdavis.edu
Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those twomore » CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t-test. Results: The mean TRE (and standard deviation) was 0.6 ± 0.7 mm (smaller than the voxel dimension) for DIR between pre contrast and postcontrast end-inspiratory CT image data sets. No singularities were observed in the displacement vector fields. The mean HU enhancement (and standard deviation) was 37.3 ± 10.5 HU for normal lung subjects and 30.7 ± 13.5 HU for diseased lung subjects. Spatial heterogeneity of regional perfusion was found to be higher for diseased lung subjects than for normal lung subjects, i.e., a mean coefficient of variation of 2.06 vs 1.59 (p = 0.07). The average gravitationally directed gradient was strong and significant (R{sup 2} = 0.99, p < 0.01) for normal lung dogs, whereas it was moderate and nonsignificant (R{sup 2} = 0.61, p = 0.12) for diseased lung dogs. Conclusions: This canine study demonstrated the accuracy of DIR with subvoxel TREs on average, higher spatial heterogeneity of regional perfusion for diseased lung subjects than for normal lung subjects, and a strong gravitationally directed gradient for normal lung subjects, providing proof-of-principle for single-energy CT pulmonary perfusion imaging. Further studies such as comparison with other perfusion imaging modalities will be necessary to validate the physiological significance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lakshmanan, M; Symons, R; Cork, T
Purpose: To demonstrate the feasibility of in vivo three-material decomposition techniques using photon-counting CT (PCCT) with possible advantage of resolving arterial and venous flow of an organ simultaneously. Methods: Abdominal PCCT scans were acquired using a prototype whole-body PCCT with four energy thresholds (25/50/75/90keV) in a canine. Bismuth subsalicylate (60 mg) was administered orally one day prior to scanning. Immediately prior to CT scan, gadoteric acid (60 ml, Dotarem, Guerbet) was intravenously injected, followed in ten minutes by a 20mL injection of iodinated contrast (iopamidol 370 mg/mL, Bracco). Scans were acquired every ∼20 seconds, starting from the time of iodinemore » injection. Linear material decomposition was performed using the least mean squares method to create concentration maps of iodine, gadolinium, and bismuth. The method was calibrated to vials with known concentrations of materials placed next to the animal. The accuracy of this method was tested on vials with known concentrations. Results: The material decomposition algorithm’s accuracy was confirmed to be within ±4mM in the test vials. In the animal, we could estimate the concentration of gadolinium in delayed-enhanced phase (10 minutes post-injection) in the abdomen. We could follow the wash-in and wash-out of iodine in arterial, venous, and excretory flow of the kidneys (20s, 80s, and 120s post-iodine injection) while gadolinium was present in the delayed-enhanced phase. Bismuth, which was used as a contrast agent for the gastro-intestinal tract, was easily differentiable from the other two contrast agents in the small intestine. Conclusion: This study shows the feasibility of using photon-counting CT with four energy thresholds to differentiate three k-edge contrast agents in vivo. This can potentially reduce radiation dose to patients by combining arterial and venous phases into a single acquisition.« less
Patel, Trishan; Elphick, Amy; Jackson, James E; Shovlin, Claire L
2016-11-01
To evaluate if injection of intravenous particles may provoke migraines in subjects with right-to-left shunts due to pulmonary arteriovenous malformations (AVMs). Migraine headaches commonly affect people with hereditary hemorrhagic telangiectasia (HHT), especially those with pulmonary AVMs that provide right-to-left shunts. In our clinical practice, patients occasionally reported acute precipitation of migraine headaches following injection of technetium-labeled albumin macroaggregates for nuclear medicine scans. Self-reported migraine features and exacerbations were examined in HHT subjects with and without pulmonary AVMs, for a series of noninvasive and invasive investigations, using an unbiased online survey. One hundred and sixty-six subjects were classified as having both HHT and migraines. HHT subjects with migraines were more likely to have pulmonary AVMs (P < .0001). HHT subjects with pulmonary AVMs were more likely to report photophobia (P = .010), "flashes of light" (P = .011), or transient visual loss (P = .040). Pulse oximetry, x-rays, ultrasound, and computerized tomography (CT) scans without intravenous contrast medium rarely, if ever, provoked migraines, but unenhanced magnetic resonance imaging (MRI) was reported to exacerbate migraines by 14/124 (11.2%) subjects. One hundred and fourteen subjects had both enhanced and unenhanced CT examinations: studies with contrast media were more commonly reported to start (9/114 [7.8%]), and/or worsen migraines (18/114 [15.7%]), compared to those undertaken without contrast medium (P < .01), or after simple blood tests (P < .05). Additionally, migraine exacerbation was reported by 9/90 (10%) after contrast echocardiography, 2/44 (4.5%) after nuclear medicine scans, and 10/154 (6.5%) after blood tests. HHT subjects frequently report migraine exacerbation following blood tests, contrast echocardiograms, MRI imaging, and CT studies performed with intravenous contrast medium. Since air emboli are recognized to complicate intravenous injections, particularly those given by a pressurized pump during contrast enhanced CT, future studies should re-evaluate whether particulate emboli provoke migraines. © 2016 The Authors Headache published by Wiley Periodicals, Inc. on behalf of American Headache Society.
Patel, Trishan; Elphick, Amy; Jackson, James E.
2016-01-01
Objective To evaluate if injection of intravenous particles may provoke migraines in subjects with right‐to‐left shunts due to pulmonary arteriovenous malformations (AVMs). Background Migraine headaches commonly affect people with hereditary hemorrhagic telangiectasia (HHT), especially those with pulmonary AVMs that provide right‐to‐left shunts. In our clinical practice, patients occasionally reported acute precipitation of migraine headaches following injection of technetium‐labeled albumin macroaggregates for nuclear medicine scans. Methods Self‐reported migraine features and exacerbations were examined in HHT subjects with and without pulmonary AVMs, for a series of noninvasive and invasive investigations, using an unbiased online survey. Results One hundred and sixty‐six subjects were classified as having both HHT and migraines. HHT subjects with migraines were more likely to have pulmonary AVMs (P < .0001). HHT subjects with pulmonary AVMs were more likely to report photophobia (P = .010), “flashes of light” (P = .011), or transient visual loss (P = .040). Pulse oximetry, x‐rays, ultrasound, and computerized tomography (CT) scans without intravenous contrast medium rarely, if ever, provoked migraines, but unenhanced magnetic resonance imaging (MRI) was reported to exacerbate migraines by 14/124 (11.2%) subjects. One hundred and fourteen subjects had both enhanced and unenhanced CT examinations: studies with contrast media were more commonly reported to start (9/114 [7.8%]), and/or worsen migraines (18/114 [15.7%]), compared to those undertaken without contrast medium (P < .01), or after simple blood tests (P < .05). Additionally, migraine exacerbation was reported by 9/90 (10%) after contrast echocardiography, 2/44 (4.5%) after nuclear medicine scans, and 10/154 (6.5%) after blood tests. Conclusions HHT subjects frequently report migraine exacerbation following blood tests, contrast echocardiograms, MRI imaging, and CT studies performed with intravenous contrast medium. Since air emboli are recognized to complicate intravenous injections, particularly those given by a pressurized pump during contrast enhanced CT, future studies should re‐evaluate whether particulate emboli provoke migraines. PMID:27727478
3D GGO candidate extraction in lung CT images using multilevel thresholding on supervoxels
NASA Astrophysics Data System (ADS)
Huang, Shan; Liu, Xiabi; Han, Guanghui; Zhao, Xinming; Zhao, Yanfeng; Zhou, Chunwu
2018-02-01
The earlier detection of ground glass opacity (GGO) is of great importance since GGOs are more likely to be malignant than solid nodules. However, the detection of GGO is a difficult task in lung cancer screening. This paper proposes a novel GGO candidate extraction method, which performs multilevel thresholding on supervoxels in 3D lung CT images. Firstly, we segment the lung parenchyma based on Otsu algorithm. Secondly, the voxels which are adjacent in 3D discrete space and sharing similar grayscale are clustered into supervoxels. This procedure is used to enhance GGOs and reduce computational complexity. Thirdly, Hessian matrix is used to emphasize focal GGO candidates. Lastly, an improved adaptive multilevel thresholding method is applied on segmented clusters to extract GGO candidates. The proposed method was evaluated on a set of 19 lung CT scans containing 166 GGO lesions from the Lung CT Imaging Signs (LISS) database. The experimental results show that our proposed GGO candidate extraction method is effective, with a sensitivity of 100% and 26.3 of false positives per scan (665 GGO candidates, 499 non-GGO regions and 166 GGO regions). It can handle both focal GGOs and diffuse GGOs.
Naghibi, Saeed; Seifirad, Sirous; Adami Dehkordi, Mahboobeh; Einolghozati, Sasan; Ghaffarian Eidgahi Moghadam, Nafiseh; Akhavan Rezayat, Amir; Seifirad, Soroush
2016-01-01
Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. This study was performed to compare the findings of three-dimensional reconstructed spiral and conventional CT scan of ossicular chain study in patients with COM. Fifty patients enrolled in the study underwent plane and three dimensional CT scan (PHILIPS-MX 8000). Ossicles changes, mastoid cavity, tympanic cavity, and presence of cholesteatoma were evaluated. Results of the two methods were then compared and interpreted by a radiologist, recorded in questionnaires, and analyzed. Logistic regression test and Kappa coefficient of agreement were used for statistical analyses. Sixty two ears with COM were found in physical examination. A significant difference was observed between the findings of the two methods in ossicle erosion (11.3% in conventional CT vs. 37.1% in spiral CT, P = 0.0001), decrease of mastoid air cells (82.3% in conventional CT vs. 93.5% in spiral CT, P = 0.001), and tympanic cavity opacity (12.9% in conventional CT vs. 40.3% in spiral CT, P=0.0001). No significant difference was observed between the findings of the two methods in ossicle destruction (6.5% conventional CT vs. 56.4% in spiral CT, P = 0.125), and presence of cholesteatoma (3.2% in conventional CT vs. 42% in spiral CT, P = 0.172). In this study, spiral CT scan demonstrated ossicle dislocation in 9.6%, decrease of mastoid air cells in 4.8%, and decrease of volume in the tympanic cavity in 1.6%; whereas, none of these findings were reported in the patients' conventional CT scans. Spiral-CT scan is superior to conventional CT in the diagnosis of lesions in COM before operation. It can be used for detailed evaluation of ossicular chain in such patients.
Interpretation of Brain CT Scans in the Field by Critical Care Physicians in a Mobile Stroke Unit
Zakariassen, Erik; Lindner, Thomas; Nome, Terje; Bache, Kristi G.; Røislien, Jo; Gleditsch, Jostein; Solyga, Volker; Russell, David; Lund, Christian G.
2017-01-01
ABSTRACT BACKGROUND AND PURPOSE In acute stroke, thromboembolism or spontaneous hemorrhage abruptly reduces blood flow to a part of the brain. To limit necrosis, rapid radiological identification of the pathological mechanism must be conducted to allow the initiation of targeted treatment. The aim of the Norwegian Acute Stroke Prehospital Project is to determine if anesthesiologists, trained in prehospital critical care, may accurately assess cerebral computed tomography (CT) scans in a mobile stroke unit (MSU). METHODS In this pilot study, 13 anesthesiologists assessed unselected acute stroke patients with a cerebral CT scan in an MSU. The scans were simultaneously available by teleradiology at the receiving hospital and the on‐call radiologist. CT scan interpretation was focused on the radiological diagnosis of acute stroke and contraindications for thrombolysis. The aim of this study was to find inter‐rater agreement between the pre‐ and in‐hospital radiological assessments. A neuroradiologist evaluated all CT scans retrospectively. Statistical analysis of inter‐rater agreement was analyzed with Cohen's kappa. RESULTS Fifty‐one cerebral CT scans from the MSU were included. Inter‐rater agreement between prehospital anesthesiologists and the in‐hospital on‐call radiologists was excellent in finding radiological selection for thrombolysis (kappa .87). Prehospital CT scans were conducted in median 10 minutes (7 and 14 minutes) in the MSU, and median 39 minutes (31 and 48 minutes) before arrival at the receiving hospital. CONCLUSION This pilot study shows that anesthesiologists trained in prehospital critical care may effectively assess cerebral CT scans in an MSU, and determine if there are radiological contraindications for thrombolysis. PMID:28766306
Meulepas, Johanna M; Ronckers, Cécile M; Smets, Anne M J B; Nievelstein, Rutger A J; Jahnen, Andreas; Lee, Choonsik; Kieft, Mariëtte; Laméris, Johan S; van Herk, Marcel; Greuter, Marcel J W; Jeukens, Cécile R L P N; van Straten, Marcel; Visser, Otto; van Leeuwen, Flora E; Hauptmann, Michael
2014-04-01
Computed tomography (CT) scans are indispensable in modern medicine; however, the spectacular rise in global use coupled with relatively high doses of ionizing radiation per examination have raised radiation protection concerns. Children are of particular concern because they are more sensitive to radiation-induced cancer compared with adults and have a long lifespan to express harmful effects which may offset clinical benefits of performing a scan. This paper describes the design and methodology of a nationwide study, the Dutch Pediatric CT Study, regarding risk of leukemia and brain tumors in children after radiation exposure from CT scans. It is a retrospective record-linkage cohort study with an expected number of 100,000 children who received at least one electronically archived CT scan covering the calendar period since the introduction of digital archiving until 2012. Information on all archived CT scans of these children will be obtained, including date of examination, scanned body part and radiologist's report, as well as the machine settings required for organ dose estimation. We will obtain cancer incidence by record linkage with external databases. In this article, we describe several approaches to the collection of data on archived CT scans, the estimation of radiation doses and the assessment of confounding. The proposed approaches provide useful strategies for data collection and confounder assessment for general retrospective record-linkage studies, particular those using hospital databases on radiological procedures for the assessment of exposure to ionizing or non-ionizing radiation.
Choi, Ji-Hoon; Yun, Jung-Won; Kim, Yong-Sung; Lee, Eun-A; Hwang, Sang-Tae; Cho, Yong-Kyun; Kim, Hong-Joo; Park, Jung-Ho; Park, Dong-Il; Sohn, Chong-Il; Jeon, Woo-Kyu; Kim, Byung-Ik; Kim, Hyoung-Ook; Shin, Jun-Ho
2008-01-01
AIM: To determine the clinical data that might be useful for differentiating benign from malignant gallbladder (GB) polyps by comparing radiological methods, including abdominal ultrasonography (US) and computed tomography (CT) scanning, with postoperative pathology findings. METHODS: Fifty-nine patients underwent laparoscopic cholecystectomy for a GB polyp of around 10 mm. They were divided into two groups, one with cholesterol polyps and the other with non-cholesterol polyps. Clinical features such as gender, age, symptoms, size and number of polyps, the presence of a GB stone, the radiologically measured maximum diameter of the polyp by US and CT scanning, and the measurements of diameter from postoperative pathology were recorded for comparative analysis. RESULTS: Fifteen of the 41 cases with cholesterol polyps (36.6%) were detected with US but not CT scanning, whereas all 18 non-cholesterol polyps were observed using both methods. In the cholesterol polyp group, the maximum measured diameter of the polyp was smaller by CT scan than by US. Consequently, the discrepancy between those two scanning measurements was greater than for the non-cholesterol polyp group. CONCLUSION: The clinical signs indicative of a cholesterol polyp include: (1) a polyp observed by US but not observable by CT scanning, (2) a smaller diameter on the CT scan compared to US, and (3) a discrepancy in its maximum diameter between US and CT measurements. In addition, US and the CT scan had low accuracy in predicting the polyp diameter compared to that determined by postoperative pathology. PMID:19058309
Choi, Ji-Hoon; Yun, Jung-Won; Kim, Yong-Sung; Lee, Eun-A; Hwang, Sang-Tae; Cho, Yong-Kyun; Kim, Hong-Joo; Park, Jung-Ho; Park, Dong-Il; Sohn, Chong-Il; Jeon, Woo-Kyu; Kim, Byung-Ik; Kim, Hyoung-Ook; Shin, Jun-Ho
2008-11-28
To determine the clinical data that might be useful for differentiating benign from malignant gallbladder (GB) polyps by comparing radiological methods, including abdominal ultrasonography (US) and computed tomography (CT) scanning, with postoperative pathology findings. Fifty-nine patients underwent laparoscopic cholecystectomy for a GB polyp of around 10 mm. They were divided into two groups, one with cholesterol polyps and the other with non-cholesterol polyps. Clinical features such as gender, age, symptoms, size and number of polyps, the presence of a GB stone, the radiologically measured maximum diameter of the polyp by US and CT scanning, and the measurements of diameter from postoperative pathology were recorded for comparative analysis. Fifteen of the 41 cases with cholesterol polyps (36.6%) were detected with US but not CT scanning, whereas all 18 non-cholesterol polyps were observed using both methods. In the cholesterol polyp group, the maximum measured diameter of the polyp was smaller by CT scan than by US. Consequently, the discrepancy between those two scanning measurements was greater than for the non-cholesterol polyp group. The clinical signs indicative of a cholesterol polyp include: (1) a polyp observed by US but not observable by CT scanning, (2) a smaller diameter on the CT scan compared to US, and (3) a discrepancy in its maximum diameter between US and CT measurements. In addition, US and the CT scan had low accuracy in predicting the polyp diameter compared to that determined by postoperative pathology.
Cardona Arboniés, J; Rodríguez Alfonso, B; Mucientes Rasilla, J; Martínez Ballesteros, C; Zapata Paz, I; Prieto Soriano, A; Carballido Rodriguez, J; Mitjavila Casanovas, M
To evaluate the role of the 18 F-Choline PET/CT in prostate cancer management when detecting distant disease in planning radiotherapy and staging and to evaluate the therapy changes guided by PET/TC results. A retrospective evaluation was performed on 18 F-Choline PET/CT scans of patients with prostate cancer. Staging and planning radiotherapy scans were selected in patients with at least 9 months follow up. There was a total of 56 studies, 33 (58.93%) for staging, and 23 (41.07%) for planning radiotherapy. All scans were obtained using a hybrid PET/CT scanner. The PET/CT acquisition protocol consisted of a dual-phase procedure after the administration of an intravenous injection of 296-370MBq of 18 F-Choline. There were 43 out of 56 (76.8%) scans considered as positive, and 13 (23.2%) were negative. The TNM staging was changed in 13 (23.2%) scans. The PET/CT findings ruled out distant disease in 4 out of 13 scans, and unknown distant disease was detected in 9 (69.3%) scans. 18 F-Choline PET/CT is a useful technique for detecting unknown distant disease in prostate cancer when staging and planning radiotherapy. The inclusion of 18 F-choline PET/CT should be considered in prostate cancer management protocols. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
A comparison of sequential and spiral scanning techniques in brain CT.
Pace, Ivana; Zarb, Francis
2015-01-01
To evaluate and compare image quality and radiation dose of sequential computed tomography (CT) examinations of the brain and spiral CT examinations of the brain imaged on a GE HiSpeed NX/I Dual Slice 2CT scanner. A random sample of 40 patients referred for CT examination of the brain was selected and divided into 2 groups. Half of the patients were scanned using the sequential technique; the other half were scanned using the spiral technique. Radiation dose data—both the computed tomography dose index (CTDI) and the dose length product (DLP)—were recorded on a checklist at the end of each examination. Using the European Guidelines on Quality Criteria for Computed Tomography, 4 radiologists conducted a visual grading analysis and rated the level of visibility of 6 anatomical structures considered necessary to produce images of high quality. The mean CTDI(vol) and DLP values were statistically significantly higher (P <.05) with the sequential scans (CTDI(vol): 22.06 mGy; DLP: 304.60 mGy • cm) than with the spiral scans (CTDI(vol): 14.94 mGy; DLP: 229.10 mGy • cm). The mean image quality rating scores for all criteria of the sequential scanning technique were statistically significantly higher (P <.05) in the visual grading analysis than those of the spiral scanning technique. In this local study, the sequential technique was preferred over the spiral technique for both overall image quality and differentiation between gray and white matter in brain CT scans. Other similar studies counter this finding. The radiation dose seen with the sequential CT scanning technique was significantly higher than that seen with the spiral CT scanning technique. However, image quality with the sequential technique was statistically significantly superior (P <.05).
Jacobson, Stanley; Epstein, Scott K; Albright, Susan; Ochieng, Joseph; Griffiths, Jeffrey; Coppersmith, Veronica; Polak, Joseph F
2009-08-01
The goal of this study was to determine whether computerized tomographic (CT) images of cadavers could be used in addition to images from patients to develop virtual patients (VPs) to enhance integrated learning of basic and clinical science. We imaged 13 cadavers on a Siemens CT system. The DICOM images from the CT were noted to be of high quality by a radiologist who systematically identified all abnormal and pathological findings. The pathological findings from the CT images and the cause of death were used to develop plausible clinical cases and study questions. Each case was designed to highlight and explain the abnormal anatomic findings encountered during the cadaveric dissection. A 3D reconstruction was produced using OsiriX and then formatted into a QuickTime movie which was then stored on the Tufts University Sciences Knowledgebase (TUSK) as a VP. We conclude that CT scanning of cadavers produces high-quality images that can be used to develop VPs. Although the use of the VPs was optional and fewer than half of the students had an imaged cadaver for dissection, 59 of the 172 (34%) students accessed and reviewed the cases and images positively and were very encouraging for us to continue.
Bosch de Basea, Magda; Espinosa, Ana; Gil, Mariona; Figuerola, Jordi; Pardina, Marina; Vilar, José; Cardis, Elisabeth
2018-01-01
Recent publications reported that children in disadvantaged areas undergo more CT scanning than others. The present study is aimed to assess the potential differences in CT imaging by socioeconomic status (SES) in Spanish young scanned subjects and if such differences vary with different indicators or different time point SES measurements. The associations between CT scanning and SES, and between the CT scan rate per patient and SES were investigated in the Spanish EPI-CT subcohort. Various SES indicators were studied to determine whether particular SES dimensions were more closely related to the probability of undergoing one or multiple CTs. Comparisons were made with indices based on 2001 and 2011 censuses. We found evidence of socio-economic variation among young people, mainly related to autonomous communities of residence. A slightly higher rate of scans per patient of multiple body parts in the less affluent categories was observed, possibly reflecting a higher rate of accidents and violence in these groups. The number of CT scans per patient was higher both in the most affluent and the most deprived categories and somewhat lower in the intermediate groups. This relation varied with the SES indicator used, with lower CT scans per patients in categories of high unemployment and temporary work, but not depending on categories of unskilled work or illiteracy. The relationship between these indicators and number of CTs in 2011 was different than that seen with the 2001 census, with the number of CTs increasing with higher unemployment. Overall we observed some differences in the SES distribution of scanned patients by Autonomous Community in Spain. There was, however, no major differences in the frequency of CT scans per patient by SES overall, based on the 2001 census. The use of different indicators and of SES data collected at different time points led to different relations between SES and frequency of CT scans, outlining the difficulty of adequately capturing the social and economic dimensions which may affect health and health service utilisation.
Espinosa, Ana; Gil, Mariona; Figuerola, Jordi; Pardina, Marina; Vilar, José; Cardis, Elisabeth
2018-01-01
Recent publications reported that children in disadvantaged areas undergo more CT scanning than others. The present study is aimed to assess the potential differences in CT imaging by socioeconomic status (SES) in Spanish young scanned subjects and if such differences vary with different indicators or different time point SES measurements. The associations between CT scanning and SES, and between the CT scan rate per patient and SES were investigated in the Spanish EPI-CT subcohort. Various SES indicators were studied to determine whether particular SES dimensions were more closely related to the probability of undergoing one or multiple CTs. Comparisons were made with indices based on 2001 and 2011 censuses. We found evidence of socio-economic variation among young people, mainly related to autonomous communities of residence. A slightly higher rate of scans per patient of multiple body parts in the less affluent categories was observed, possibly reflecting a higher rate of accidents and violence in these groups. The number of CT scans per patient was higher both in the most affluent and the most deprived categories and somewhat lower in the intermediate groups. This relation varied with the SES indicator used, with lower CT scans per patients in categories of high unemployment and temporary work, but not depending on categories of unskilled work or illiteracy. The relationship between these indicators and number of CTs in 2011 was different than that seen with the 2001 census, with the number of CTs increasing with higher unemployment. Overall we observed some differences in the SES distribution of scanned patients by Autonomous Community in Spain. There was, however, no major differences in the frequency of CT scans per patient by SES overall, based on the 2001 census. The use of different indicators and of SES data collected at different time points led to different relations between SES and frequency of CT scans, outlining the difficulty of adequately capturing the social and economic dimensions which may affect health and health service utilisation. PMID:29723272
An electron beam linear scanning mode for industrial limited-angle nano-computed tomography.
Wang, Chengxiang; Zeng, Li; Yu, Wei; Zhang, Lingli; Guo, Yumeng; Gong, Changcheng
2018-01-01
Nano-computed tomography (nano-CT), which utilizes X-rays to research the inner structure of some small objects and has been widely utilized in biomedical research, electronic technology, geology, material sciences, etc., is a high spatial resolution and non-destructive research technique. A traditional nano-CT scanning model with a very high mechanical precision and stability of object manipulator, which is difficult to reach when the scanned object is continuously rotated, is required for high resolution imaging. To reduce the scanning time and attain a stable and high resolution imaging in industrial non-destructive testing, we study an electron beam linear scanning mode of nano-CT system that can avoid mechanical vibration and object movement caused by the continuously rotated object. Furthermore, to further save the scanning time and study how small the scanning range could be considered with acceptable spatial resolution, an alternating iterative algorithm based on ℓ 0 minimization is utilized to limited-angle nano-CT reconstruction problem with the electron beam linear scanning mode. The experimental results confirm the feasibility of the electron beam linear scanning mode of nano-CT system.
An electron beam linear scanning mode for industrial limited-angle nano-computed tomography
NASA Astrophysics Data System (ADS)
Wang, Chengxiang; Zeng, Li; Yu, Wei; Zhang, Lingli; Guo, Yumeng; Gong, Changcheng
2018-01-01
Nano-computed tomography (nano-CT), which utilizes X-rays to research the inner structure of some small objects and has been widely utilized in biomedical research, electronic technology, geology, material sciences, etc., is a high spatial resolution and non-destructive research technique. A traditional nano-CT scanning model with a very high mechanical precision and stability of object manipulator, which is difficult to reach when the scanned object is continuously rotated, is required for high resolution imaging. To reduce the scanning time and attain a stable and high resolution imaging in industrial non-destructive testing, we study an electron beam linear scanning mode of nano-CT system that can avoid mechanical vibration and object movement caused by the continuously rotated object. Furthermore, to further save the scanning time and study how small the scanning range could be considered with acceptable spatial resolution, an alternating iterative algorithm based on ℓ0 minimization is utilized to limited-angle nano-CT reconstruction problem with the electron beam linear scanning mode. The experimental results confirm the feasibility of the electron beam linear scanning mode of nano-CT system.
NASA Astrophysics Data System (ADS)
Wang, Shiyang; Lu, Zhengfeng; Fan, Xiaobing; Medved, Milica; Jiang, Xia; Sammet, Steffen; Yousuf, Ambereen; Pineda, Federico; Oto, Aytekin; Karczmar, Gregory S.
2018-02-01
The purpose of this study was to evaluate the accuracy of arterial input functions (AIFs) measured from dynamic contrast enhanced (DCE) MRI following a low dose of contrast media injection. The AIFs measured from DCE computed tomography (CT) were used as ‘gold standard’. A total of twenty patients received CT and MRI scans on the same day. Patients received 120 ml Iohexol in DCE-CT and a low dose of (0.015 mM kg-1) of gadobenate dimeglumine in DCE-MRI. The AIFs were measured in the iliac artery and normalized to the CT and MRI contrast agent doses. To correct for different temporal resolution and sampling periods of CT and MRI, an empirical mathematical model (EMM) was used to fit the AIFs first. Then numerical AIFs (AIFCT and AIFMRI) were calculated based on fitting parameters. The AIFMRI was convolved with a ‘contrast agent injection’ function (AIFMRICON ) to correct for the difference between MRI and CT contrast agent injection times (~1.5 s versus 30 s). The results show that the EMMs accurately fitted AIFs measured from CT and MRI. There was no significant difference (p > 0.05) between the maximum peak amplitude of AIFs from CT (22.1 ± 4.1 mM/dose) and MRI after convolution (22.3 ± 5.2 mM/dose). The shapes of the AIFCT and AIFMRICON were very similar. Our results demonstrated that AIFs can be accurately measured by MRI following low dose contrast agent injection.
Nedd, K; Sfakianakis, G; Ganz, W; Uricchio, B; Vernberg, D; Villanueva, P; Jabir, A M; Bartlett, J; Keena, J
1993-01-01
Single photon emission computed tomography (SPECT) with Technetium-99m hexamethyl propylenamine oxime (Tc-99m-HMPAO) was used in 20 patients with mild to moderate traumatic brain injury (TBI) to evaluate the effects of brain trauma on regional cerebral blood flow (rCBF). SPECT scan was compared with CT scan in 16 patients. SPECT showed intraparenchymal differences in rCBF more often than lesions diagnosed with CT scans (87.5% vs. 37.5%). In five of six patients with lesions in both modalities, the area of involvement was relatively larger on SPECT scans than on CT scans. Contrecoup changes were seen in five patients on SPECT alone, two patients with CT alone and one patient had contrecoup lesions on CT and SPECT. Of the eight patients (50%) with skull fractures, seven (43.7%) had rCBF findings on SPECT scan and five (31.3%) demonstrated decrease in rCBF in brain underlying the fracture. All these patients with fractures had normal brain on CT scans. Conversely, extra-axial lesions and fractures evident on CT did not visualize on SPECT, but SPECT demonstrated associated changes in rCBF. Although there is still lack of clinical and pathological correlation, SPECT appears to be a promising method for a more sensitive evaluation of axial lesions in patients with mild to moderate TBI.
Dual energy micro CT SkyScan 1173 for the characterization of urinary stone
NASA Astrophysics Data System (ADS)
Fitri, L. A.; Asyana, V.; Ridwan, T.; Anwary, F.; Soekersi, H.; Latief, F. D. E.; Haryanto, F.
2016-03-01
Knowledge of the composition of urinary stones is an essential part to determine suitable treatments for patients. The aim of this research is to characterize the urinary stones by using dual energy micro CT SkyScan 11173. This technique combines high-energy and low- energy scanning during a single acquisition. Six human urinary stones were scanned in vitro using 80 kV and 120 kV micro CT SkyScan 1173. Projected images were produced by micro CT SkyScan 1173 and then reconstructed using NRecon (in-house software from SkyScan) to obtain a complete 3D image. The urinary stone images were analysed using CT analyser to obtain information of internal structure and Hounsfield Unit (HU) values to determine the information regarding the composition of the urinary stones, respectively. HU values obtained from some regions of interest in the same slice are compared to a reference HU. The analysis shows information of the composition of the six scanned stones obtained. The six stones consist of stone number 1 (calcium+cystine), number 2 (calcium+struvite), number 3 (calcium+cystine+struvite), number 4 (calcium), number 5 (calcium+cystine+struvite), and number 6 (calcium+uric acid). This shows that dual energy micro CT SkyScan 1173 was able to characterize the composition of the urinary stone.
Quantitative myocardial perfusion from static cardiac and dynamic arterial CT
NASA Astrophysics Data System (ADS)
Bindschadler, Michael; Branch, Kelley R.; Alessio, Adam M.
2018-05-01
Quantitative myocardial blood flow (MBF) estimation by dynamic contrast enhanced cardiac computed tomography (CT) requires multi-frame acquisition of contrast transit through the blood pool and myocardium to inform the arterial input and tissue response functions. Both the input and the tissue response functions for the entire myocardium are sampled with each acquisition. However, the long breath holds and frequent sampling can result in significant motion artifacts and relatively high radiation dose. To address these limitations, we propose and evaluate a new static cardiac and dynamic arterial (SCDA) quantitative MBF approach where (1) the input function is well sampled using either prediction from pre-scan timing bolus data or measured from dynamic thin slice ‘bolus tracking’ acquisitions, and (2) the whole-heart tissue response data is limited to one contrast enhanced CT acquisition. A perfusion model uses the dynamic arterial input function to generate a family of possible myocardial contrast enhancement curves corresponding to a range of MBF values. Combined with the timing of the single whole-heart acquisition, these curves generate a lookup table relating myocardial contrast enhancement to quantitative MBF. We tested the SCDA approach in 28 patients that underwent a full dynamic CT protocol both at rest and vasodilator stress conditions. Using measured input function plus single (enhanced CT only) or plus double (enhanced and contrast free baseline CT’s) myocardial acquisitions yielded MBF estimates with root mean square (RMS) error of 1.2 ml/min/g and 0.35 ml/min/g, and radiation dose reductions of 90% and 83%, respectively. The prediction of the input function based on timing bolus data and the static acquisition had an RMS error compared to the measured input function of 26.0% which led to MBF estimation errors greater than threefold higher than using the measured input function. SCDA presents a new, simplified approach for quantitative perfusion imaging with an acquisition strategy offering substantial radiation dose and computational complexity savings over dynamic CT.
SU-F-T-403: Impact of Dose Reduction for Simulation CT On Radiation Therapy Treatment Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Q; Shah, P; Li, S
Purpose: To investigate the feasibility of applying ALARA principles to current treatment planning CT scans. The study aims to quantitatively verify lower dose scans does not alter treatment planning. Method: Gammex 467 tissue characterization phantom with inserts of 14 different materials was scanned at seven different mA levels (30∼300 mA). CT numbers of different inserts were measured. Auto contouring for bone and lung in treatment planning system (Pinnacle) was used to evaluate the effect of CT number accuracy from treatment planning aspect, on the 30 and 300 mA-scanned images. A head CT scan intended for a 3D whole brain radiationmore » treatment was evaluated. Dose calculations were performed on normal scanned images using clinical protocol (120 kVP, Smart mA, maximum 291 mA), and the images with added simulating noise mimicking a 70 mA scan. Plan parameters including isocenter, beam arrangements, block shapes, dose grid size and resolution, and prescriptions were kept the same for these two plans. The calculated monitor units (MUs) for these two plans were compared. Results: No significant degradation of CT number accuracy was found at lower dose levels from both the phantom scans, and the patient images with added noise. The CT numbers kept consistent when mA is higher than 60 mA. The auto contoured volumes for lung and cortical bone show 0.3% and 0.12% of differences between 30 mA and 300 mA respectively. The two forward plans created on regular and low dose images gave the same calculated MU, and 98.3% of points having <1% of dose difference. Conclusion: Both phantom and patient studies quantitatively verified low dose CT provides similar quality for treatment planning at 20–25% of regular scan dose. Therefore, there is the potential to optimize simulation CT scan protocol to fulfil the ALARA principle and limit unnecessary radiation exposure to non-targeted tissues.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Chuong, M; Choi, W
Purpose: To identify PET/CT based imaging predictors of anal cancer recurrence and evaluate baseline vs. mid-treatment vs. post-treatment PET/CT scans in the tumor recurrence prediction. Methods: FDG-PET/CT scans were obtained at baseline, during chemoradiotherapy (CRT, midtreatment), and after CRT (post-treatment) in 17 patients of anal cancer. Four patients had tumor recurrence. For each patient, the mid-treatment and post-treatment scans were respectively aligned to the baseline scan by a rigid registration followed by a deformable registration. PET/CT image features were computed within the manually delineated tumor volume of each scan to characterize the intensity histogram, spatial patterns (texture), and shape ofmore » the tumors, as well as the changes of these features resulting from CRT. A total of 335 image features were extracted. An Exact Logistic Regression model was employed to analyze these PET/CT image features in order to identify potential predictors for tumor recurrence. Results: Eleven potential predictors of cancer recurrence were identified with p < 0.10, including five shape features, five statistical texture features, and one CT intensity histogram feature. Six features were indentified from posttreatment scans, 3 from mid-treatment scans, and 2 from baseline scans. These features indicated that there were differences in shape, intensity, and spatial pattern between tumors with and without recurrence. Recurrent tumors tended to have more compact shape (higher roundness and lower elongation) and larger intensity difference between baseline and follow-up scans, compared to non-recurrent tumors. Conclusion: PET/CT based anal cancer recurrence predictors were identified. The post-CRT PET/CT is the most important scan for the prediction of cancer recurrence. The baseline and mid-CRT PET/CT also showed value in the prediction and would be more useful for the predication of tumor recurrence in early stage of CRT. This work was supported in part by the National Cancer Institute Grant R01CA172638.« less
USDA-ARS?s Scientific Manuscript database
Relatively few studies have examined the effects of formula feeding relative to breast-feeding on bone in the neonate. Using peripheral quantitative CT scan and histomorphometric analysis, we demonstrated that neonatal piglets fed with soy-based formula (SF) and cow milk-based formula (MF) for 21 or...
NASA Astrophysics Data System (ADS)
Kim, Sangroh; Yoshizumi, Terry T.; Yin, Fang-Fang; Chetty, Indrin J.
2013-04-01
Currently, the BEAMnrc/EGSnrc Monte Carlo (MC) system does not provide a spiral CT source model for the simulation of spiral CT scanning. We developed and validated a spiral CT phase-space source model in the BEAMnrc/EGSnrc system. The spiral phase-space source model was implemented in the DOSXYZnrc user code of the BEAMnrc/EGSnrc system by analyzing the geometry of spiral CT scan—scan range, initial angle, rotational direction, pitch, slice thickness, etc. Table movement was simulated by changing the coordinates of the isocenter as a function of beam angles. Some parameters such as pitch, slice thickness and translation per rotation were also incorporated into the model to make the new phase-space source model, designed specifically for spiral CT scan simulations. The source model was hard-coded by modifying the ‘ISource = 8: Phase-Space Source Incident from Multiple Directions’ in the srcxyznrc.mortran and dosxyznrc.mortran files in the DOSXYZnrc user code. In order to verify the implementation, spiral CT scans were simulated in a CT dose index phantom using the validated x-ray tube model of a commercial CT simulator for both the original multi-direction source (ISOURCE = 8) and the new phase-space source model in the DOSXYZnrc system. Then the acquired 2D and 3D dose distributions were analyzed with respect to the input parameters for various pitch values. In addition, surface-dose profiles were also measured for a patient CT scan protocol using radiochromic film and were compared with the MC simulations. The new phase-space source model was found to simulate the spiral CT scanning in a single simulation run accurately. It also produced the equivalent dose distribution of the ISOURCE = 8 model for the same CT scan parameters. The MC-simulated surface profiles were well matched to the film measurement overall within 10%. The new spiral CT phase-space source model was implemented in the BEAMnrc/EGSnrc system. This work will be beneficial in estimating the spiral CT scan dose in the BEAMnrc/EGSnrc system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miao, J; Fan, J; Gopinatha Pillai, A
Purpose: To further reduce CT dose, a practical sparse-view acquisition scheme is proposed to provide the same attenuation estimation as higher dose for PET imaging in the extended scan field-of-view. Methods: CT scans are often used for PET attenuation correction and can be acquired at very low CT radiation dose. Low dose techniques often employ low tube voltage/current accompanied with a smooth filter before backprojection to reduce CT image noise. These techniques can introduce bias in the conversion from HU to attenuation values, especially in the extended CT scan field-of-view (FOV). In this work, we propose an ultra-low dose CTmore » technique for PET attenuation correction based on sparse-view acquisition. That is, instead of an acquisition of full amount of views, only a fraction of views are acquired. We tested this technique on a 64-slice GE CT scanner using multiple phantoms. CT scan FOV truncation completion was performed based on the published water-cylinder extrapolation algorithm. A number of continuous views per rotation: 984 (full), 246, 123, 82 and 62 have been tested, corresponding to a CT dose reduction of none, 4x, 8x, 12x and 16x. We also simulated sparse-view acquisition by skipping views from the fully-acquired view data. Results: FBP reconstruction with Q. AC filter on reduced views in the full extended scan field-of-view possesses similar image quality to the reconstruction on acquired full view data. The results showed a further potential for dose reduction compared to the full acquisition, without sacrificing any significant attenuation support to the PET. Conclusion: With the proposed sparse-view method, one can potential achieve at least 2x more CT dose reduction compared to the current Ultra-Low Dose (ULD) PET/CT protocol. A pre-scan based dose modulation scheme can be combined with the above sparse-view approaches, which can even further reduce the CT scan dose during a PET/CT exam.« less
Use of PET/CT scanning in cancer patients: technical and practical considerations
2005-01-01
This overview of the oncologic applications of positron emission tomography (PET) focuses on the technical aspects and clinical applications of a newer technique: the combination of a PET scanner and a computed tomography (CT) scanner in a single (PET/CT) device. Examples illustrate how PET/CT contributes to patient care and improves upon the previous state-of-the-art method of comparing a PET scan with a separate CT scan. Finally, the author presents some of the results from studies of PET/CT imaging that are beginning to appear in the literature. PMID:16252023
Shuryak, Igor; Lubin, Jay H; Brenner, David J
2014-06-01
Recent epidemiological studies have suggested that radiation exposure from pediatric CT scanning is associated with small excess cancer risks. However, the majority of CT scans are performed on adults, and most radiation-induced cancers appear during middle or old age, in the same age range as background cancers. Consequently, a logical next step is to investigate the effects of CT scanning in adulthood on lifetime cancer risks by conducting adult-based, appropriately designed epidemiological studies. Here we estimate the sample size required for such studies to detect CT-associated risks. This was achieved by incorporating different age-, sex-, time- and cancer type-dependent models of radiation carcinogenesis into an in silico simulation of a population-based cohort study. This approach simulated individual histories of chest and abdominal CT exposures, deaths and cancer diagnoses. The resultant sample sizes suggest that epidemiological studies of realistically sized cohorts can detect excess lifetime cancer risks from adult CT exposures. For example, retrospective analysis of CT exposure and cancer incidence data from a population-based cohort of 0.4 to 1.3 million (depending on the carcinogenic model) CT-exposed UK adults, aged 25-65 in 1980 and followed until 2015, provides 80% power for detecting cancer risks from chest and abdominal CT scans.
Post-traumatic hepatic arterial pseudoaneurysm and arterioportal shunt.
Maes, J; D'Archambeau, O; Snoeckx, A; Op de Beeck, B; Voormolen, M; Parizel, P M
2010-01-01
The authors report the case of a 21-year-old man who suffered from a blunt abdominal trauma. Initial imaging revealed a liver laceration at the right lobe, a perirenal hematoma of the right kidney and a hematoma of the right adrenal gland. Follow-up MDCT-scan on day 10 after admission showed at the arterial-phase contrast-enhanced study perfusion alterations and two hepatic pseudoaneurysms. The diagnosis of pseudoaneurysm was confirmed and treated angiographically with superselective coil embolization. A follow-up CT-scan on day 17 showed at a nontreated area an arterioportal shunt and a wedge-shaped transient hepatic parenchymal enhancement. This was confirmed angiographically and subsequently treated with coil embolization.
The Beatles, the Nobel Prize, and CT scanning of the chest.
Goodman, Lawrence R
2010-01-01
From its first test scan on a mouse, in 1967, to current medical practice, the CT scanner has become a core imaging tool in thoracic diagnosis. Initially financed by money from Beatles' record sales, the first patient scan was performed in 1971. Only 8 years later, a Nobel Prize in Physics and Medicine was awarded to Hounsfield and Cormack for their discovery. This article traces the history of CT scanner development and how each technical advance expanded chest diagnostic frontiers. Chest imaging now accounts for 30% of all CT scanning.
Trends and patterns of computed tomography scan use among children in The Netherlands: 1990-2012.
Meulepas, Johanna M; Smets, Anne M J B; Nievelstein, Rutger A J; Gradowska, Patrycja; Verbeke, Jonathan; Holscher, Herma C; Rutten, Matthieu J C M; Kieft, Mariëtte; Ronckers, Cécile M; Hauptmann, Michael
2017-06-01
To evaluate trends and patterns in CT usage among children (aged 0-17 years) in The Netherlands during the period 1990-2012. Lists of electronically archived paediatric CT scans were requested from the Radiology Information Systems (RIS) of Dutch hospitals which reported >10 paediatric CT scans annually in a survey conducted in 2010. Data included patient identification, birth date, gender, scan date and body part scanned. For non-participating hospitals and for years prior to electronic archiving in some participating hospitals, data were imputed by calendar year and hospital type (academic, general with <500 beds, general with ≥ 500 beds). Based on 236,066 CT scans among 146,368 patients performed between 1990 and 2012, estimated annual numbers of paediatric CT scans in The Netherlands increased from 7,731 in 1990 to 26,023 in 2012. More than 70 % of all scans were of the head and neck. During the last decade, substantial increases of more than 5 % per year were observed in general hospitals with fewer than 500 beds and among children aged 10 years or older. The estimated number of paediatric CT scans has more than tripled in The Netherlands during the last two decades. • Paediatric CT in The Netherlands has tripled during the last two decades. • The number of paediatric CTs increased through 2012 in general hospitals. • Paediatric CTs continued to increase among children aged 10 years or older.
Benedict, Leo Andrew; Paulus, Jessica K; Rideout, Leslie; Chwals, Walter J
2014-01-01
To assess whether pediatric trauma patients initially evaluated at referring institutions met Massachusetts statewide trauma field triage criteria for stabilization and immediate transfer to a Pediatric Trauma Center (PTC) without pre-transfer CT imaging. A 3-year retrospective cohort study was completed at our level 1 PTC. Patients with CT imaging at referring institutions were classified according to a triage scheme based on Massachusetts statewide trauma field triage criteria. Demographic data and injury profile characteristics were abstracted from patient medical records and our pediatric trauma registry. A total of 262 patients with 413 CT scans were reviewed from 2008 to 2011. 172 patients scanned (66%, 95% CI: 60%, 71%) met criteria for immediate transfer to a pediatric trauma center. Notably, 110 scans (27% of the total performed at referring institutions) were duplicated within four hours upon arrival to our PTC. GCS score <14 (45%) was the most common requirement for transfer, and CT scan of the head was the most frequent scan obtained (53%). The majority of pediatric trauma patients were subjected to CT scans at referring institutions despite meeting Massachusetts trauma triage guidelines that call for stabilization and immediate transfer to a pediatric trauma center without any CT imaging. © 2014.
Zhang, Bin; Dong, Yuhao; Liang, Long; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Chen, Wenbo; Li, Xinyu; Liang, Changhong; Zhang, Shuixing
2016-03-01
Some epidemiologic surveillance studies have recorded adverse drug reactions to radiocontrast agents. We aimed to investigate the incidence and management of acute adverse reactions (AARs) to Ultravist-370 and Isovue-370 in patients who underwent contrast-enhanced computed tomography (CT) scanning.Data from 137,473 patients were analyzed. They had undergone enhanced CT scanning with intravenous injection of Ultravist-370 or Isovue-370 during the period of January 1, 2006 to December 31, 2012 in our hospital. We investigated and classified AARs according to the American College of Radiology and the Chinese Society of Radiology (CSR) guidelines for iodinated contrast media. We analyzed risk factors for AARs and compared the AARs induced by Ultravist-370 and Isovue-370.Four hundred and twenty-eight (0.31%) patients experienced AARs, which included 330 (0.24%) patients with mild AARs, 82 (0.06%) patients with moderate AARs, and 16 (0.01%) patients with severe AARs (including 3 cases of cardiac arrest and one case of death). The incidence of AARs was higher with Ultravist-370 than with Isovue-370 (0.38% vs 0.24%, P < 0.001), but only for mild AARs (0.32% vs 0.16%, P < 0.001). Analyses on risk factors indicated that female patients (n = 221, 0.43%, P < 0.001), emergency patients (n = 11, 0.51%, P < 0.001), elderly patients aged 50 to 60 years (n = 135, 0.43%, P < 0.001), and patients who underwent coronary computed tomography angiography (CTA) (n = 55, 0.51%, P < 0.001) had a higher risk of AARs. Cutaneous manifestations (50.52%)-especially rash (59.74%)-were the most frequent mild AARs. Cardiovascular manifestations accounted for most moderate and severe AARs (62.91% and 48.28%, respectively). After proper management, the symptoms and signs of 96.5% of the AARs resolved within 24 hours without sequelae.Ultravist-370 and Isovue-370 are safe for patients undergoing enhanced CT scanning. The incidence of AARs is higher with Ultravist-370 than with Isovue-370, but this difference is limited only to the mild AARs. The incidence of AARs could be affected by multiple factors.
Zhang, Bin; Dong, Yuhao; Liang, Long; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Chen, Wenbo; Li, Xinyu; Liang, Changhong; Zhang, Shuixing
2016-01-01
Abstract Some epidemiologic surveillance studies have recorded adverse drug reactions to radiocontrast agents. We aimed to investigate the incidence and management of acute adverse reactions (AARs) to Ultravist-370 and Isovue-370 in patients who underwent contrast-enhanced computed tomography (CT) scanning. Data from 137,473 patients were analyzed. They had undergone enhanced CT scanning with intravenous injection of Ultravist-370 or Isovue-370 during the period of January 1, 2006 to December 31, 2012 in our hospital. We investigated and classified AARs according to the American College of Radiology and the Chinese Society of Radiology (CSR) guidelines for iodinated contrast media. We analyzed risk factors for AARs and compared the AARs induced by Ultravist-370 and Isovue-370. Four hundred and twenty-eight (0.31%) patients experienced AARs, which included 330 (0.24%) patients with mild AARs, 82 (0.06%) patients with moderate AARs, and 16 (0.01%) patients with severe AARs (including 3 cases of cardiac arrest and one case of death). The incidence of AARs was higher with Ultravist-370 than with Isovue-370 (0.38% vs 0.24%, P < 0.001), but only for mild AARs (0.32% vs 0.16%, P < 0.001). Analyses on risk factors indicated that female patients (n = 221, 0.43%, P < 0.001), emergency patients (n = 11, 0.51%, P < 0.001), elderly patients aged 50 to 60 years (n = 135, 0.43%, P < 0.001), and patients who underwent coronary computed tomography angiography (CTA) (n = 55, 0.51%, P < 0.001) had a higher risk of AARs. Cutaneous manifestations (50.52%)—especially rash (59.74%)—were the most frequent mild AARs. Cardiovascular manifestations accounted for most moderate and severe AARs (62.91% and 48.28%, respectively). After proper management, the symptoms and signs of 96.5% of the AARs resolved within 24 hours without sequelae. Ultravist-370 and Isovue-370 are safe for patients undergoing enhanced CT scanning. The incidence of AARs is higher with Ultravist-370 than with Isovue-370, but this difference is limited only to the mild AARs. The incidence of AARs could be affected by multiple factors. PMID:27015204
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozyer, Umut, E-mail: umutozyer@gmail.com
IntroductionSpontaneous hematoma refractory to conservative management is a potentially serious condition that requires prompt diagnosis and intervention. The purpose of this study was to evaluate the performance of computed tomography (CT) in the treatment planning and to report the effectiveness of transcatheter embolization with N-butyl-2-cyanoacrylate (NBCA).Materials and MethodsForty-one interventions in 38 patients within a 12-year period were evaluated. CT and angiograms were reviewed for the location of the hematoma, the presence of extravasation, and the correlation of CT and angiography findings.ResultsArterial extravasation was present on 34/39 CT scans. Angiograms confirmed the CT scans in 29 cases. Angiograms revealed extravasation inmore » four cases which CT showed venous bleeding (n = 2) or no bleeding (n = 2). Five patients with arterial and 1 patient with venous extravasation on CT images had no extravasation on angiograms. Embolization was performed to all arteries with extravasation on angiograms. Empiric embolization of the corresponding artery on the CT was performed when there was no extravasation on angiograms. Embolization procedures were performed with 15 % NBCA diluted with iodized oil. Technical success was achieved in 40/41 (97.6 %) interventions. Clinical success was achieved in 35 patients with a single, in 1 patient with 2, and in 1 patient with 3 interventions. No complications related to embolization procedure occurred. None of the patients died due to a progression of the hematoma.ConclusionNBCA is an effective and safe embolic agent to treat hematoma refractory to conservative management. Contrast-enhanced CT may provide faster and more effective intervention.Level of Evidence IIIRetrospective.« less
Gignac, Paul M; Kley, Nathan J; Clarke, Julia A; Colbert, Matthew W; Morhardt, Ashley C; Cerio, Donald; Cost, Ian N; Cox, Philip G; Daza, Juan D; Early, Catherine M; Echols, M Scott; Henkelman, R Mark; Herdina, A Nele; Holliday, Casey M; Li, Zhiheng; Mahlow, Kristin; Merchant, Samer; Müller, Johannes; Orsbon, Courtney P; Paluh, Daniel J; Thies, Monte L; Tsai, Henry P; Witmer, Lawrence M
2016-06-01
Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward. © 2016 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.
2018-01-01
Objective To determine whether the body size-adapted volume computed tomography (CT) dose index (CTDvol) in pediatric cardiothoracic CT with tube current modulation is better to be entered before or after scan range adjustment for radiation dose optimization. Materials and Methods In 83 patients, cardiothoracic CT with tube current modulation was performed with the body size-adapted CTDIvol entered after (group 1, n = 42) or before (group 2, n = 41) scan range adjustment. Patient-related, radiation dose, and image quality parameters were compared and correlated between the two groups. Results The CTDIvol after the CT scan in group 1 was significantly higher than that in group 2 (1.7 ± 0.1 mGy vs. 1.4 ± 0.3 mGy; p < 0.0001). Image noise (4.6 ± 0.5 Hounsfield units [HU] vs. 4.5 ± 0.7 HU) and image quality (1.5 ± 0.6 vs. 1.5 ± 0.6) showed no significant differences between the two (p > 0.05). In both groups, all patient-related parameters, except body density, showed positive correlations (r = 0.49–0.94; p < 0.01) with the CTDIvol before and after the CT scan. The CTDIvol after CT scan showed modest positive correlation (r = 0.49; p ≤ 0.001) with image noise in group 1 but no significant correlation (p > 0.05) in group 2. Conclusion In pediatric cardiothoracic CT with tube current modulation, the CTDIvol entered before scan range adjustment provides a significant dose reduction (18%) with comparable image quality compared with that entered after scan range adjustment.
Is there a trend in CT scanning scaphoid nonunions for deformity assessment?-A systematic review.
Ten Berg, Paul W L; de Roo, Marieke G A; Maas, Mario; Strackee, Simon D
2017-06-01
The effect of scaphoid nonunion deformity on wrist function is uncertain due to the lack of reliable imaging tools. Advanced three-dimensional (3-D) computed tomography (CT)-based imaging techniques may improve deformity assessment by using a mirrored image of the contralateral intact wrist as anatomic reference. The implementation of such techniques depends on the extent to which conventional CT is currently used in standard practice. The purpose of this systematic review of medical literature was to analyze the trend in CT scanning scaphoid nonunions, either unilaterally or bilaterally. Using Medline and Embase databases, two independent reviewers searched for original full-length clinical articles describing series with at least five patients focusing on reconstructive surgery of scaphoid nonunions with bone grafting and/or fixation, from the years 2000-2015. We excluded reports focusing on only nonunions suspected for avascular necrosis and/or treated with vascularized bone grafting, as their workup often includes magnetic resonance imaging. For data analysis, we evaluated the use of CT scans and distinguished between uni- and bilateral, and pre- and postoperative scans. Seventy-seven articles were included of which 16 were published between 2000 and 2005, 19 between 2006 and 2010, and 42 between 2011 and 2015. For these consecutive intervals, the rates of articles describing the use of pre- and postoperative CT scans increased from 13%, to 16%, to 31%, and from 25%, to 32%, to 52%, respectively. Hereof, only two (3%) articles described the use of bilateral CT scans. There is an evident trend in performing unilateral CT scans before and after reconstructive surgery of a scaphoid nonunion. To improve assessment of scaphoid nonunion deformity using 3-D CT-based imaging techniques, we recommend scanning the contralateral wrist as well. Copyright © 2017 Elsevier B.V. All rights reserved.
Hall, David O; Hooper, Clare E; Searle, Julie; Darby, Michael; White, Paul; Harvey, John E; Braybrooke, Jeremy P; Maskell, Nick A; Masani, Vidan; Lyburn, Iain D
2018-02-01
The purpose of this study was to compare the use of fluorine-18-fluorodeoxyglucose (F-FDG) PET with computed tomography (CT) and dynamic contrast-enhanced (DCE) MRI to predict prognosis and monitor treatment in malignant pleural mesothelioma. F-FDG PET/CT and DCE-MRI studies carried out as part of the South West Area Mesothelioma Pemetrexed trial were used. F-FDG PET/CT and DCE-MRI studies were carried out before treatment, and after two cycles of chemotherapy, on patients treated with pemetrexed and cisplatin. A total of 73 patients were recruited, of whom 65 had PET/CT and DCE-MRI scans. Baseline measurements from F-FDG PET/CT (maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis) and DCE-MRI (integrated area under the first 90s of the curve and washout slope) were compared with overall survival (OS) using Kaplan-Meier and Cox regression analyses, and changes in imaging measurements were compared with disease progression. PET/CT and DCE-MRI measurements were not correlated with each other. Maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis were significantly related to OS with Cox regression analysis and Kaplan-Meir analysis, and DCE-MRI washout curve shape was significantly related to OS. DCE-MRI curve shape can be combined with F-FDG PET/CT to give additional prognostic information. Changes in measurements were not related to progression-free survival. F-FDG PET/CT and DCE-MRI give prognostic information in malignant pleural mesothelioma. Neither PET/CT nor DCE-MRI is useful for monitoring disease progression.
Eidel, Oliver; Burth, Sina; Neumann, Jan-Oliver; Kieslich, Pascal J; Sahm, Felix; Jungk, Christine; Kickingereder, Philipp; Bickelhaupt, Sebastian; Mundiyanapurath, Sibu; Bäumer, Philipp; Wick, Wolfgang; Schlemmer, Heinz-Peter; Kiening, Karl; Unterberg, Andreas; Bendszus, Martin; Radbruch, Alexander
2017-01-01
To correlate histopathologic findings from biopsy specimens with their corresponding location within enhancing areas, non-enhancing areas and necrotic areas on contrast enhanced T1-weighted MRI scans (cT1). In 37 patients with newly diagnosed glioblastoma who underwent stereotactic biopsy, we obtained a correlation of 561 1mm3 biopsy specimens with their corresponding position on the intraoperative cT1 image at 1.5 Tesla. Biopsy points were categorized as enhancing (CE), non-enhancing (NE) or necrotic (NEC) on cT1 and tissue samples were categorized as "viable tumor cells", "blood" or "necrotic tissue (with or without cellular component)". Cell counting was done semi-automatically. NE had the highest content of tissue categorized as viable tumor cells (89% vs. 60% in CE and 30% NEC, respectively). Besides, the average cell density for NE (3764 ± 2893 cells/mm2) was comparable to CE (3506 ± 3116 cells/mm2), while NEC had a lower cell density with 2713 ± 3239 cells/mm2. If necrotic parts and bleeds were excluded, cell density in biopsies categorized as "viable tumor tissue" decreased from the center of the tumor (NEC, 5804 ± 3480 cells/mm2) to CE (4495 ± 3209 cells/mm2) and NE (4130 ± 2817 cells/mm2). The appearance of a glioblastoma on a cT1 image (circular enhancement, central necrosis, peritumoral edema) does not correspond to its diffuse histopathological composition. Cell density is elevated in both CE and NE parts. Hence, our study suggests that NE contains considerable amounts of infiltrative tumor with a high cellularity which might be considered in resection planning.
The Effect of the Presence of EEG Leads on Image Quality in Cerebral Perfusion SPECT and FDG PET/CT.
Zhang, Lulu; Yen, Stephanie P; Seltzer, Marc A; Thomas, George P; Willis, Kristen; Siegel, Alan
2018-06-08
Rationale: Cerebral perfusion SPECT and 18 F-FDG PET/CT are commonly performed diagnostic procedures for patients suffering from epilepsy. Individuals receiving these tests are often in-patients undergoing examinations with EEG leads. We have routinely removed these leads before these tests due to concerns that they would lead to imaging artifacts. The leads would then be replaced at the conclusion of the scan. The goal of our study was to determine if the EEG leads actually do cause artifacts that could lead to erroneous scan interpretation or make the scan uninterpretable. Methods: PET/CT with 18 F-FDG and SPECT with technetium-99m ECD were performed on a two dimensional brain phantom. The phantom was scanned with standard leads, CT/MR compatible leads and with no leads. The scans were interpreted by three experienced nuclear medicine physicians who were asked to rank the images by quality and then to determine if they could differentiate each of the scans from a scan in which it was indicated that no leads were present. Results: No differences could be detected between SPECT or PET scans performed without leads or with either set of leads. The standard EEG leads did create an artifact in the CT portion of the PET/CT while the CT/MR compatible leads did not. Conclusion: This phantom study suggest that EEG leads, standard or CT/MR compatible do not need to be removed for SPECT or for PET. Further study evaluating the effect on patients scan would be of value to support this conclusion. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Radiation Dose Reduction by Indication-Directed Focused z-Direction Coverage for Neck CT.
Parikh, A K; Shah, C C
2016-06-01
The American College of Radiology-American Society of Neuroradiology-Society for Pediatric Radiology Practice Parameter for a neck CT suggests that coverage should be from the sella to the aortic arch. It also recommends using CT scans judiciously to achieve the clinical objective. Our purpose was to analyze the potential dose reduction by decreasing the scan length of a neck CT and to assess for any clinically relevant information that might be missed from this modified approach. This retrospective study included 126 children who underwent a neck CT between August 1, 2013, and September 30, 2014. Alteration of the scan length for the modified CT was suggested on the topographic image on the basis of the indication of the study, with the reader blinded to the images and the report. The CT dose index volume of the original scan was multiplied by the new scan length to calculate the dose-length product of the modified study. The effective dose was calculated for the original and modified studies by using age-based conversion factors from the American Association of Physicists in Medicine Report No. 96. Decreasing the scan length resulted in an average estimated dose reduction of 47%. The average reduction in scan length was 10.4 cm, decreasing the overall coverage by 48%. The change in scan length did not result in any missed findings that altered management. Of the 27 abscesses in this study, none extended to the mediastinum. All of the lesions in question were completely covered. Decreasing the scan length of a neck CT according to the indication provides a significant savings in radiation dose, while not altering diagnostic ability or management. © 2016 by American Journal of Neuroradiology.
Calibration free beam hardening correction for cardiac CT perfusion imaging
NASA Astrophysics Data System (ADS)
Levi, Jacob; Fahmi, Rachid; Eck, Brendan L.; Fares, Anas; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.
2016-03-01
Myocardial perfusion imaging using CT (MPI-CT) and coronary CTA have the potential to make CT an ideal noninvasive gate-keeper for invasive coronary angiography. However, beam hardening artifacts (BHA) prevent accurate blood flow calculation in MPI-CT. BH Correction (BHC) methods require either energy-sensitive CT, not widely available, or typically a calibration-based method. We developed a calibration-free, automatic BHC (ABHC) method suitable for MPI-CT. The algorithm works with any BHC method and iteratively determines model parameters using proposed BHA-specific cost function. In this work, we use the polynomial BHC extended to three materials. The image is segmented into soft tissue, bone, and iodine images, based on mean HU and temporal enhancement. Forward projections of bone and iodine images are obtained, and in each iteration polynomial correction is applied. Corrections are then back projected and combined to obtain the current iteration's BHC image. This process is iterated until cost is minimized. We evaluate the algorithm on simulated and physical phantom images and on preclinical MPI-CT data. The scans were obtained on a prototype spectral detector CT (SDCT) scanner (Philips Healthcare). Mono-energetic reconstructed images were used as the reference. In the simulated phantom, BH streak artifacts were reduced from 12+/-2HU to 1+/-1HU and cupping was reduced by 81%. Similarly, in physical phantom, BH streak artifacts were reduced from 48+/-6HU to 1+/-5HU and cupping was reduced by 86%. In preclinical MPI-CT images, BHA was reduced from 28+/-6 HU to less than 4+/-4HU at peak enhancement. Results suggest that the algorithm can be used to reduce BHA in conventional CT and improve MPI-CT accuracy.
SU-F-I-40: Impact of Scan Length On Patient Dose in Abdomen/pelvis CT Diagnosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, I; Song, J; Kim, K
Purpose: To analysis the impact of scan length on patient doses in abdomen/pelvis CT diagnosis of each hospital. Methods: Scan length of 7 hospitals from abdomen/pelvis CT diagnosis was surveyed in Korea. Surveyed scan lengths were additional distance above diaphragm and distance below pubic symphysis except for standard scan range between diaphragm and pubic symphysis. Patient dose was estimated for adult male and female according to scan length of each hospital. CT-Expo was used to estimate the patient dose under identical equipment settings (120 kVp, 100 mAs, 10 mm collimation width, etc.) except scan length. Effective dose was calculated bymore » using tissue weighting factor of ICRP 103 recommendation. Increase rate of effective dose was calculated comparing with effective dose of standard scan range Results: Scan lengths of abdomen/pelvis CT diagnosis of each hospital were different. Also effective dose was increased with increasing the scan length. Generally increasing the distance above diaphragm caused increase of effective dose of male and female, but increasing the distance below pubic symphysis caused increase of effective dose of male. Conclusion: We estimated the patient dose according to scan length of each hospital in abdomen/pelvis CT diagnosis. Effective dose was increased by increasing the scan length because dose of organs with high tissue weighting factor such as lung, breast, testis were increased. Scan length is important factor on patient dose in CT diagnosis. If radiologic technologist interested in patient dose, decreasing the unnecessary scan length will decrease the risk of patients from radiation. This research was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: HI13C0004).« less
Three-dimensional surface reconstruction for industrial computed tomography
NASA Technical Reports Server (NTRS)
Vannier, M. W.; Knapp, R. H.; Gayou, D. E.; Sammon, N. P.; Butterfield, R. L.; Larson, J. W.
1985-01-01
Modern high resolution medical computed tomography (CT) scanners can produce geometrically accurate sectional images of many types of industrial objects. Computer software has been developed to convert serial CT scans into a three-dimensional surface form, suitable for display on the scanner itself. This software, originally developed for imaging the skull, has been adapted for application to industrial CT scanning, where serial CT scans thrrough an object of interest may be reconstructed to demonstrate spatial relationships in three dimensions that cannot be easily understood using the original slices. The methods of three-dimensional reconstruction and solid modeling are reviewed, and reconstruction in three dimensions from CT scans through familiar objects is demonstrated.
Shin, Hee Jeong; Kim, Song Soo; Lee, Jae-Hwan; Park, Jae-Hyeong; Jeong, Jin-Ok; Jin, Seon Ah; Shin, Byung Seok; Shin, Kyung-Sook; Ahn, Moonsang
2016-06-01
To evaluate the feasibility of low-concentration contrast medium (CM) for vascular enhancement, image quality, and radiation dose on computed tomography aortography (CTA) using a combined low-tube-voltage and iterative reconstruction (IR) technique. Ninety subjects underwent dual-source CT (DSCT) operating in dual-source, high-pitch mode. DSCT scans were performed using both high-concentration CM (Group A, n = 50; Iomeprol 400) and low-concentration CM (Group B, n = 40; Iodixanol 270). Group A was scanned using a reference tube potential of 120 kVp and 120 reference mAs under automatic exposure control with IR. Group B was scanned using low-tube-voltage (80 or 100 kVp if body mass index ≥25 kg/m(2)) at a fixed current of 150 mAs, along with IR. Images of the two groups were compared regarding attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), iodine load, and radiation dose in various locations of the CTA. In comparison between Group A and Group B, the average mean attenuation (454.73 ± 86.66 vs. 515.96 ± 101.55 HU), SNR (25.28 ± 4.34 vs. 31.29 ± 4.58), and CNR (21.83 ± 4.20 vs. 27.55 ± 4.81) on CTA in Group B showed significantly greater values and significantly lower image noise values (18.76 ± 2.19 vs. 17.48 ± 3.34) than those in Group A (all Ps < 0.05). Homogeneous contrast enhancement from the ascending thoracic aorta to the infrarenal abdominal aorta was significantly superior in Group B (P < 0.05). Low-concentration CM and a low-tube-voltage combination technique using IR is a feasible method, showing sufficient contrast enhancement and image quality.
CT stands for computerized tomography. In this procedure, a thin X-ray beam is rotated around the ... D image of a section through the body. CT scans are very detailed and provide excellent information ...
Li, Qi; Zhang, Gang; Huang, Yuan-Jun; Dong, Mei-Xue; Lv, Fa-Jin; Wei, Xiao; Chen, Jian-Jun; Zhang, Li-Juan; Qin, Xin-Yue; Xie, Peng
2015-08-01
Early hematoma growth is not uncommon in patients with intracerebral hemorrhage and is an independent predictor of poor functional outcome. The purpose of our study was to report and validate the use of our newly identified computed tomographic (CT) blend sign in predicting early hematoma growth. Patients with intracerebral hemorrhage who underwent baseline CT scan within 6 hours after onset of symptoms were included. The follow-up CT scan was performed within 24 hours after the baseline CT scan. Significant hematoma growth was defined as an increase in hematoma volume of >33% or an absolute increase of hematoma volume of >12.5 mL. The blend sign on admission nonenhanced CT was defined as blending of hypoattenuating area and hyperattenuating region with a well-defined margin. Univariate and multivariable logistic regression analyses were performed to assess the relationship between the presence of the blend sign on nonenhanced admission CT and early hematoma growth. A total of 172 patients were included in our study. Blend sign was observed in 29 of 172 (16.9%) patients with intracerebral hemorrhage on baseline nonenhanced CT scan. Of the 61 patients with hematoma growth, 24 (39.3%) had blend sign on admission CT scan. Interobserver agreement for identifying blend sign was excellent between the 2 readers (κ=0.957). The multivariate logistic regression analysis demonstrated that the time to baseline CT scan, initial hematoma volume, and presence of blend sign on baseline CT scan to be independent predictors of early hematoma growth. The sensitivity, specificity, positive and negative predictive values of blend sign for predicting hematoma growth were 39.3%, 95.5%, 82.7%, and 74.1%, respectively. The CT blend sign could be easily identified on regular nonenhanced CT and is highly specific for predicting hematoma growth. © 2015 American Heart Association, Inc.
2009-01-01
Background Computed Tomography (CT) has become a widely used supplement to medico legal autopsies at several forensic institutes. Amongst other things, it has proven to be very valuable in visualising fractures of the cranium. Also CT scan data are being used to create head models for biomechanical trauma analysis by Finite Element Analysis. If CT scan data are to be used for creating individual head models for retrograde trauma analysis in the future we need to ascertain how well cranial fractures are captured by CT scan. The purpose of this study was to compare the diagnostic agreement between CT and autopsy regarding cranial fractures and especially the precision with which cranial fractures are recorded. Methods The autopsy fracture diagnosis was compared to the diagnosis of two CT readings (reconstructed with Multiplanar and Maximum Intensity Projection reconstructions) by registering the fractures on schematic drawings. The extent of the fractures was quantified by merging 3-dimensional datasets from both the autopsy as input by 3D digitizer tracing and CT scan. Results The results showed a good diagnostic agreement regarding fractures localised in the posterior fossa, while the fracture diagnosis in the medial and anterior fossa was difficult at the first CT scan reading. The fracture diagnosis improved during the second CT scan reading. Thus using two different CT reconstructions improved diagnosis in the medial fossa and at the impact points in the cranial vault. However, fracture diagnosis in the anterior and medial fossa and of hairline fractures in general still remained difficult. Conclusion The study showed that the forensically important fracture systems to a large extent were diagnosed on CT images using Multiplanar and Maximum Intensity Projection reconstructions. Difficulties remained in the minute diagnosis of hairline fractures. These inconsistencies need to be resolved in order to use CT scan data of victims for individual head modelling and trauma analysis. PMID:19835570
Cooper, Jennifer N; Lodwick, Daniel L; Adler, Brent; Lee, Choonsik; Minneci, Peter C; Deans, Katherine J
2017-06-01
Computed tomography (CT) is a widely used diagnostic tool in pediatric medicine. However, due to concerns regarding radiation exposure, it is essential to identify patient characteristics associated with higher radiation burden from CT imaging, in order to more effectively target efforts towards dose reduction. Our objective was to identify the effects of various demographic and clinical patient characteristics on radiation exposure from single abdomen/pelvis CT scans in children. CT scans performed at our institution between January 2013 and August 2015 in patients under 16 years of age were processed using a software tool that estimates patient-specific organ and effective doses and merges these estimates with data from the electronic health record and billing record. Quantile regression models at the 50th, 75th, and 90th percentiles were used to estimate the effects of patients' demographic and clinical characteristics on effective dose. 2390 abdomen/pelvis CT scans (median effective dose 1.52mSv) were included. Of all characteristics examined, only older age, female gender, higher BMI, and whether the scan was a multiphase exam or an exam that required repeating for movement were significant predictors of higher effective dose at each quantile examined (all p<0.05). The effects of obesity and multiphase or repeat scanning on effective dose were magnified in higher dose scans. Older age, female gender, obesity, and multiphase or repeat scanning are all associated with increased effective dose from abdomen/pelvis CT. Targeted efforts to reduce dose from abdominal CT in these groups should be undertaken. Copyright © 2017 Elsevier Ltd. All rights reserved.
Assessing stapes piston position using computed tomography: a cadaveric study.
Hahn, Yoav; Diaz, Rodney; Hartman, Jonathan; Bobinski, Matthew; Brodie, Hilary
2009-02-01
Temporal bone computed tomographic (CT) scanning in the postoperative stapedotomy patient is inaccurate in assessing stapes piston position within the vestibule. Poststapedotomy patients that have persistent vertigo may undergo CT scanning to assess the position of the stapes piston within the vestibule to rule out overly deep insertion. Vertigo is a recognized complication of the deep piston, and CT evaluation is often recommended. The accuracy of CT scan in this setting is unestablished. Stapedotomy was performed on 12 cadaver ears, and stainless steel McGee pistons were placed. The cadaver heads were then scanned using a fine-cut temporal bone protocol. Temporal bone dissection was performed with microscopic measurement of the piston depth in the vestibule. These values were compared with depth of intravestibular penetration measured on CT scan by 4 independent measurements. The intravestibular penetration as assessed by computed tomography was consistently greater than the value found on cadaveric anatomic dissection. The radiographic bias was greater when piston location within the vestibule was shallower. The axial CT scan measurement was 0.53 mm greater, on average, than the anatomic measurement. On average, the coronal CT measurement was 0.68 mm greater than the anatomic measurement. The degree of overestimation of penetration, however, was highly inconsistent. Standard temporal bone CT scan is neither an accurate nor precise examination of stapes piston depth within the vestibule. We found that CT measurement consistently overstated intravestibular piston depth. Computed tomography is not a useful study in the evaluation of piston depth for poststapedectomy vertigo and is of limited value in this setting.
Neural network and its application to CT imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nikravesh, M.; Kovscek, A.R.; Patzek, T.W.
We present an integrated approach to imaging the progress of air displacement by spontaneous imbibition of oil into sandstone. We combine Computerized Tomography (CT) scanning and neural network image processing. The main aspects of our approach are (I) visualization of the distribution of oil and air saturation by CT, (II) interpretation of CT scans using neural networks, and (III) reconstruction of 3-D images of oil saturation from the CT scans with a neural network model. Excellent agreement between the actual images and the neural network predictions is found.
Evaluation of a semiautomated lung mass calculation technique for internal dosimetry applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Busse, Nathan; Erwin, William; Pan, Tinsu
2013-12-15
Purpose: The authors sought to evaluate a simple, semiautomated lung mass estimation method using computed tomography (CT) scans obtained using a variety of acquisition techniques and reconstruction parameters for mass correction of medical internal radiation dose-based internal radionuclide radiation absorbed dose estimates.Methods: CT scans of 27 patients with lung cancer undergoing stereotactic body radiation therapy treatment planning with PET/CT were analyzed retrospectively. For each patient, free-breathing (FB) and respiratory-gated 4DCT scans were acquired. The 4DCT scans were sorted into ten respiratory phases, representing one complete respiratory cycle. An average CT reconstruction was derived from the ten-phase reconstructions. Mid expiration breath-holdmore » CT scans were acquired in the same session for many patients. Deep inspiration breath-hold diagnostic CT scans of many of the patients were obtained from different scanning sessions at similar time points to evaluate the effect of contrast administration and maximum inspiration breath-hold. Lung mass estimates were obtained using all CT scan types, and intercomparisons made to assess lung mass variation according to scan type. Lung mass estimates using the FB CT scans from PET/CT examinations of another group of ten male and ten female patients who were 21–30 years old and did not have lung disease were calculated and compared with reference lung mass values. To evaluate the effect of varying CT acquisition and reconstruction parameters on lung mass estimation, an anthropomorphic chest phantom was scanned and reconstructed with different CT parameters. CT images of the lungs were segmented using the OsiriX MD software program with a seed point of about −850 HU and an interval of 1000. Lung volume, and mean lung, tissue, and air HUs were recorded for each scan. Lung mass was calculated by assuming each voxel was a linear combination of only air and tissue. The specific gravity of lung volume was calculated using the formula (lung HU − air HU)/(tissue HU − air HU), and mass = specific gravity × total volume × 1.04 g/cm{sup 3}.Results: The range of calculated lung masses was 0.51–1.29 kg. The average male and female lung masses during FB CT were 0.80 and 0.71 kg, respectively. The calculated lung mass varied across the respiratory cycle but changed to a lesser degree than did lung volume measurements (7.3% versus 15.4%). Lung masses calculated using deep inspiration breath-hold and average CT were significantly larger (p < 0.05) than were some masses calculated using respiratory-phase and FB CT. Increased voxel size and smooth reconstruction kernels led to high lung mass estimates owing to partial volume effects.Conclusions: Organ mass correction is an important component of patient-specific internal radionuclide dosimetry. Lung mass calculation necessitates scan-based density correction to account for volume changes owing to respiration. The range of lung masses in the authors’ patient population represents lung doses for the same absorbed energy differing from 25% below to 64% above the dose found using reference phantom organ masses. With proper management of acquisition parameters and selection of FB or midexpiration breath hold scans, lung mass estimates with about 10% population precision may be achieved.« less
... PET - chest; PET - lung; PET - tumor imaging; PET/CT - lung; Solitary pulmonary nodule - PET ... minutes. PET scans are performed along with a CT scan. This is because the combined information from ...
Rationale and Application of Tangential Scanning to Industrial Inspection of Hardwood Logs
Nand K. Gupta; Daniel L. Schmoldt; Bruce Isaacson
1998-01-01
Industrial computed tomography (CT) inspection of hardwood logs has some unique requirements not found in other CT applications. Sawmill operations demand that large volumes of wood be scanned quickly at high spatial resolution for extended duty cycles. Current CT scanning geometries and commercial systems have both technical and economic [imitations. Tangential...
Automatic segmentation of thoracic aorta segments in low-dose chest CT
NASA Astrophysics Data System (ADS)
Noothout, Julia M. H.; de Vos, Bob D.; Wolterink, Jelmer M.; Išgum, Ivana
2018-03-01
Morphological analysis and identification of pathologies in the aorta are important for cardiovascular diagnosis and risk assessment in patients. Manual annotation is time-consuming and cumbersome in CT scans acquired without contrast enhancement and with low radiation dose. Hence, we propose an automatic method to segment the ascending aorta, the aortic arch and the thoracic descending aorta in low-dose chest CT without contrast enhancement. Segmentation was performed using a dilated convolutional neural network (CNN), with a receptive field of 131 × 131 voxels, that classified voxels in axial, coronal and sagittal image slices. To obtain a final segmentation, the obtained probabilities of the three planes were averaged per class, and voxels were subsequently assigned to the class with the highest class probability. Two-fold cross-validation experiments were performed where ten scans were used to train the network and another ten to evaluate the performance. Dice coefficients of 0.83 +/- 0.07, 0.86 +/- 0.06 and 0.88 +/- 0.05, and Average Symmetrical Surface Distances (ASSDs) of 2.44 +/- 1.28, 1.56 +/- 0.68 and 1.87 +/- 1.30 mm were obtained for the ascending aorta, the aortic arch and the descending aorta, respectively. The results indicate that the proposed method could be used in large-scale studies analyzing the anatomical location of pathology and morphology of the thoracic aorta.
Rifaximin suppresses background intestinal 18F-FDG uptake on PET/CT scans.
Franquet, Elisa; Palmer, Mathew R; Gifford, Anne E; Selen, Daryl J; Chen, Yih-Chieh S; Sedora-Roman, Neda; Joyce, Robin M; Kolodny, Gerald M; Moss, Alan C
2014-10-01
Identification of cancer or inflammatory bowel disease in the intestinal tract by PET/computed tomography (CT) imaging can be hampered by physiological uptake of F-fluorodeoxyglucose (F-FDG) in the normal colon. Previous work has localized this F-FDG uptake to the intestinal lumen, predominantly occupied by bacteria. We sought to determine whether pretreatment with an antibiotic could reduce F-FDG uptake in the healthy colon. Thirty patients undergoing restaging PET/CT for nongastrointestinal lymphoma were randomly selected to receive rifaximin 550 mg twice daily for 2 days before their scan (post-rifaximin). Their PET/CT images were compared with those from their prior study (pre-rifaximin). Cecal maximum standard uptake value (SUVmax) and overall colonic F-FDG uptake were compared between scans. All PET/CT images were blindly scored by a radiologist. The same comparison of sequential scans was also undertaken in 30 patients who did not receive antibiotics. Thirty post-rifaximin scans were compared with 30 pre-rifaximin scans in the same patients. SUVmax in the cecum was significantly lower in the patient's post-rifaximin scans than in their pre-rifaximin scans (P=0.002). The percentage of scans with greater than grade 1 colonic F-FDG uptake was significantly lower in the post-rifaximin scans than in the pre-rifaximin scans (P<0.05). In contrast, there was no significant difference in the paired sequential scans from control patients, nor a reduction in the percentage of scans with greater than grade 1 colonic F-FDG uptake. This pilot study shows that treatment with rifaximin for 2 days before PET/CT scanning can significantly reduce physiological F-FDG uptake in the normal colonic lumen.
Sharp, Nicole E; Raghavan, Maneesha U; Svetanoff, Wendy J; Thomas, Priscilla T; Sharp, Susan W; Brown, James C; Rivard, Douglas C; St Peter, Shawn D; Holcomb, George W
2014-06-01
We compare the amount of radiation children receive from CT scans performed at non-dedicated pediatric facilities (OH) versus those at a dedicated children's hospital (CH). Using a retrospective chart review, all children undergoing CT scanning for appendicitis at an OH were compared to children undergoing CT imaging for appendicitis at a CH between January 2011 and November 2012. One hundred sixty-three children underwent CT scans at 42 different OH. Body mass index was similar between the two groups (21.00±6.49kg/m(2), 19.58±5.18kg/m(2), P=0.07). Dose length product (DLP) was 620±540.3 at OH and 253.78±211.08 at CH (P < 0.001). OH CT scans accurately diagnosed appendicitis in 81%, while CT scans at CH were accurate in 95% (P=0.026). CTDIvol was recorded in 65 patients with subset analysis showing CTDIvol of 16.98±15.58 and 4.89±2.64, a DLP of 586.25±521.59 and 143.54±41.19, and size-specific dose estimate (SSDE) of 26.71±23.1 and 3.81±2.02 at OH and CH, respectively (P<0.001). Using SSDE as a marker for radiation exposure, children received 86% less radiation and had improved diagnostic accuracy when CT scans are performed at a CH. Copyright © 2014 Elsevier Inc. All rights reserved.
Dutta, Pinaki R; Riaz, Nadeem; McBride, Sean; Morris, Luc G; Patel, Snehal; Ganly, Ian; Wong, Richard J; Palmer, Frank; Schöder, Heiko; Lee, Nancy
2016-04-01
The purpose of this study was for us to present our evaluation of the effectiveness of positron emission tomography (PET)/CT imaging in postoperative patients with oral cavity squamous cell carcinoma (SCC) before initiating adjuvant radiation therapy. Treatment planning PET/CT scans were obtained in 44 patients with oral cavity SCC receiving adjuvant radiation. We identified target areas harboring macroscopic disease requiring higher radiation doses or additional surgery. Fourteen PET/CT scans were abnormal. Thirteen patients underwent surgery and/or biopsy, increased radiation dose, and/or addition of chemotherapy. Eleven patients received higher radiation doses. Patients undergoing imaging >8 weeks were more likely to have abnormal results (p = .01). One-year distant metastases-free survival was significantly worse in patients with positive PET/CT scans (61.5% vs 92.7%; p = .01). The estimated positive predictive value (PPV) was 38% for postoperative PET/CT scanning. We demonstrated that 32% of patients have abnormal PET/CT scans resulting in management changes. Patients may benefit from postoperative PET/CT imaging to optimize adjuvant radiation treatment planning. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1285-E1293, 2016. © 2015 Wiley Periodicals, Inc.
den Harder, A M; Bangert, F; van Hamersvelt, R W; Leiner, T; Milles, Julien; Schilham, A M R; Willemink, M J; de Jong, P A
2017-12-01
To assess the effect of iodine attenuation on pulmonary nodule volumetry using virtual non-contrast (VNC) and mono-energetic reconstructions. A consecutive series of patients who underwent a contrast-enhanced chest CT scan were included. Images were acquired on a novel dual-layer spectral CT system. Conventional reconstructions as well as VNC and mono-energetic images at different keV levels were used for nodule volumetry. Twenty-four patients with a total of 63 nodules were included. Conventional reconstructions showed a median (interquartile range) volume and diameter of 174 (87 - 253) mm 3 and 6.9 (5.4 - 9.9) mm, respectively. VNC reconstructions resulted in a significant volume reduction of 5.5% (2.6 - 11.2%; p<0.001). Mono-energetic reconstructions showed a correlation between nodule attenuation and nodule volume (Spearman correlation 0.77, (0.49 - 0.94)). Lowering the keV resulted in increased volumes while higher keV levels resulted in decreased pulmonary nodule volumes compared to conventional CT. Novel dual-layer spectral CT offers the possibility to reconstruct VNC and mono-energetic images. Those reconstructions show that higher pulmonary nodule attenuation results in larger nodule volumes. This may explain the reported underestimation in nodule volume on non-contrast enhanced compared to contrast-enhanced acquisitions. • Pulmonary nodule volumes were measured on virtual non-contrast and mono-energetic reconstructions • Mono-energetic reconstructions showed that higher attenuation results in larger volumes • This may explain the reported nodule volume underestimation on non-contrast enhanced CT • Mostly metastatic pulmonary nodules were evaluated, results might differ for benign nodules.
SU-E-I-13: Evaluation of Metal Artifact Reduction (MAR) Software On Computed Tomography (CT) Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, V; Kohli, K
2015-06-15
Purpose: A new commercially available metal artifact reduction (MAR) software in computed tomography (CT) imaging was evaluated with phantoms in the presence of metals. The goal was to assess the ability of the software to restore the CT number in the vicinity of the metals without impacting the image quality. Methods: A Catphan 504 was scanned with a GE Optima RT 580 CT scanner (GE Healthcare, Milwaukee, WI) and the images were reconstructed with and without the MAR software. Both datasets were analyzed with Image Owl QA software (Image Owl Inc, Greenwich, NY). CT number sensitometry, MTF, low contrast, uniformity,more » noise and spatial accuracy were compared for scans with and without MAR software. In addition, an in-house made phantom was scanned with and without a stainless steel insert at three different locations. The accuracy of the CT number and metal insert dimension were investigated as well. Results: Comparisons between scans with and without MAR algorithm on the Catphan phantom demonstrate similar results for image quality. However, noise was slightly higher for the MAR algorithm. Evaluation of the CT number at various locations of the in-house made phantom was also performed. The baseline HU, obtained from the scan without metal insert, was compared to scans with the stainless steel insert at 3 different locations. The HU difference between the baseline scan versus metal scan was improved when the MAR algorithm was applied. In addition, the physical diameter of the stainless steel rod was over-estimated by the MAR algorithm by 0.9 mm. Conclusion: This work indicates with the presence of metal in CT scans, the MAR algorithm is capable of providing a more accurate CT number without compromising the overall image quality. Future work will include the dosimetric impact on the MAR algorithm.« less
Menditto, Vincenzo G; Lucci, Moira; Polonara, Stefano; Pomponio, Giovanni; Gabrielli, Armando
2012-06-01
Patients receiving warfarin who experience minor head injury are at risk of intracranial hemorrhage, and optimal management after a single head computed tomography (CT) scan is unclear. We evaluate a protocol of 24-hour observation followed by a second head CT scan. In this prospective case series, we enrolled consecutive patients receiving warfarin and showing no intracranial lesions on a first CT scan after minor head injury treated at a Level II trauma center. We implemented a structured clinical pathway, including 24-hour observation and a CT scan performed before discharge. We then evaluated the frequency of death, admission, neurosurgery, and delayed intracranial hemorrhage. We enrolled and observed 97 consecutive patients. Ten refused the second CT scan and were well during 30-day follow-up. Repeated CT scanning in the remaining 87 patients revealed a new hemorrhage lesion in 5 (6%), with 3 subsequently hospitalized and 1 receiving craniotomy. Two patients discharged after completing the study protocol with 2 negative CT scan results were admitted 2 and 8 days later with symptomatic subdural hematomas; neither received surgery. Two of the 5 patients with delayed bleeding at 24 hours had an initial international normalized ratio greater than 3.0, as did both patients with delayed bleeding beyond 24 hours. The relative risk of delayed hemorrhage with an initial international normalized ratio greater than 3.0 was 14 (95% confidence interval 4 to 49). For patients receiving warfarin who experience minor head injury and have a negative initial head CT scan result, a protocol of 24-hour observation followed by a second CT scan will identify most occurrences of delayed bleeding. An initial international normalized ratio greater than 3 suggests higher risk. Copyright © 2011 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Prieto-Peña, Diana; Martínez-Rodríguez, Isabel; Loricera, Javier; Banzo, Ignacio; Calderón-Goercke, Mónica; Calvo-Río, Vanesa; González-Vela, Carmen; Corrales, Alfonso; Castañeda, Santos; Blanco, Ricardo; Hernández, José L; González-Gay, Miguel Á
2018-05-18
Polymyalgia rheumatica (PMR) is often the presenting manifestation of giant cell arteritis (GCA). Fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) scan often discloses the presence of large vessel vasculitis (LVV) in PMR patients. We aimed to identify predictive factors of a positive PET/CT scan for LVV in patients classified as having isolated PMR according to well-established criteria. A set of consecutive patients with PMR from a single hospital were assessed. All of them underwent PET/CT scan between January 2010 and February 2018 based on clinical considerations. Patients with PMR associated to other diseases, including those with cranial features of GCA, were excluded. The remaining patients were categorized in classic PMR (if fulfilled the 2012 EULAR/ACR classification criteria at disease diagnosis; n = 84) or atypical PMR (who did not fulfill these criteria; n = 16). Only information on patients with classic PMR was assessed. The mean age of the 84 patients (51 women) with classic PMR was 71.4 ± 9.2 years. A PET/CT scan was positive in 51 (60.7%). Persistence of classic PMR symptoms was the most common reason to perform a PET/CT scan. Nevertheless, patients with positive PET/CT scan often had unusual symptoms. The best set of predictors of a positive PET/CT scan were bilateral diffuse lower limb pain (OR = 8.8, 95% CI: 1.7-46.3; p = 0.01), pelvic girdle pain (OR = 4.9, 95% CI: 1.50-16.53; p = 0.01) and inflammatory low back pain (OR = 4.7, 95% CI: 1.03-21.5; p = 0.04). Inflammatory low back pain, pelvic girdle and diffuse lower limb pain are predictors of positive PET/CT scan for LVV in PMR. Copyright © 2018 Elsevier Inc. All rights reserved.
WE-EF-207-09: Single-Scan Dual-Energy CT Using Primary Modulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrongolo, M; Zhu, L
Purpose: Compared with conventional CT, dual energy CT (DECT) provides better material differentiation but requires projection data with two different effective x-ray spectra. Current DECT scanners use either a two-scan setting or costly imaging components, which are not feasible or available on open-gantry cone-beam CT systems. We propose a hardware-based method which utilizes primary modulation to enable single-scan DECT on a conventional CT scanner. The CT imaging geometry of primary modulation is identical to that used in our previous method for scatter removal, making it possible for future combination with effective scatter correction on the same CT scanner. Methods: Wemore » insert an attenuation sheet with a spatially-varying pattern - primary modulator-between the x-ray source and the imaged object. During the CT scan, the modulator selectively hardens the x-ray beam at specific detector locations. Thus, the proposed method simultaneously acquires high and low energy data. High and low energy CT images are then reconstructed from projections with missing data via an iterative CT reconstruction algorithm with gradient weighting. Proof-of-concept studies are performed using a copper modulator on a cone-beam CT system. Results: Our preliminary results on the Catphan(c) 600 phantom indicate that the proposed method for single-scan DECT is able to successfully generate high-quality high and low energy CT images and distinguish different materials through basis material decomposition. By applying correction algorithms and using all of the acquired projection data, we can reconstruct a single CT image of comparable image quality to conventional CT images, i.e., without primary modulation. Conclusion: This work shows great promise in using a primary modulator to perform high-quality single-scan DECT imaging. Future studies will test method performance on anthropomorphic phantoms and perform quantitative analyses on image qualities and DECT decomposition accuracy. We will use simulations to optimize the modulator material and geometry parameters.« less
Estimating the lifetime risk of cancer associated with multiple CT scans.
Ivanov, V K; Kashcheev, V V; Chekin, S Yu; Menyaylo, A N; Pryakhin, E A; Tsyb, A F; Mettler, F A
2014-12-01
Multiple CT scans are often done on the same patient resulting in an increased risk of cancer. Prior publications have estimated risks on a population basis and often using an effective dose. Simply adding up the risks from single scans does not correctly account for the survival function. A methodology for estimating personal radiation risks attributed to multiple CT imaging using organ doses is presented in this article. The estimated magnitude of the attributable risk fraction for the possible development of radiation-induced cancer indicates the necessity for strong clinical justification when ordering multiple CT scans.
[Non-operation management of 12 cases with brain abscess demonstrated by CT scan].
Long, J
1990-12-01
This paper reported 12 cases with brain abscess demonstrated by CT scan. Using antibiotic management without surgical intervention, in 10 cases the curative effects were satisfactory. The paper indicated that CT scan was very useful in prompt and correct diagnosis of brain abscess and with sequential CT scan medical therapy was feasible. It is significant in treatment of brain abscess especially for the patients who have a poor general condition, have the brain abscess located in important functional area or have multiple abscesses so that the operation is difficult for them.
Vomiting--is this a good indication for CT head scans in patients with minor head injury?
Bainbridge, J; Khirwadkar, H; Hourihan, M D
2012-02-01
The National Institute for Health and Clinical Excellence head injury guidelines advise CT imaging within 1 h if there is more than one episode of vomiting post-head injury in adults and three or more episodes in children. Since the guideline publication, studies have found that, following head injury, vomiting alone is associated with an abnormal CT head scan in 13-45% of cases. CT head scan requests referred from the emergency department between 1 May 2009 and 30 April 2010 were retrospectively reviewed. Patients with vomiting as the sole indication for an "immediate" CT head scan performed within 1 h were included in the study. Reports produced by experienced neuroradiologists were reviewed and the detection of significant head injury was noted. There were 1264 CT head scans performed during our study period. 151 (124 adults, 27 children) were indicated owing to vomiting following head injury. 5 of the 124 adult scans and 1 of the 27 paediatric scans showed an abnormal finding, giving positive predictive values (PPV) of 4% and 3.7%, respectively. None of these patients required either acute or delayed neurosurgical intervention. In our experience, vomiting alone has a PPV of 4% for significant head injury in adults. However, none of these injuries were serious enough to warrant acute or delayed intervention. Given these findings, vomiting following head injury is a reasonable indication for a CT head scan; however, as none of the patients required acute intervention, we suggest that these scans do not usually need to be performed within 1 h of request.
Hubbard, Logan; Lipinski, Jerry; Ziemer, Benjamin; Malkasian, Shant; Sadeghi, Bahman; Javan, Hanna; Groves, Elliott M; Dertli, Brian; Molloi, Sabee
2018-01-01
Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (P FPA and P MSM ) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (P MICRO ), as follows: P FPA_COMBINED = 1.02 P MICRO_COMBINED + 0.11 (r = 0.96) and P MSM_COMBINED = 0.28 P MICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.
Abudurexiti, Abulajiang; Kameda, Masashi; Sato, Eiichi; Abderyim, Purkhet; Enomoto, Toshiyuki; Watanabe, Manabu; Hitomi, Keitaro; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Takahashi, Kiyomi; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2010-07-01
An energy-discrimination K-edge X-ray computed tomography (CT) system is useful for increasing the contrast resolution of a target region by utilizing contrast media. The CT system has a cadmium telluride (CdTe) detector, and a projection curve is obtained by linear scanning with use of the CdTe detector in conjunction with an X-stage. An object is rotated by a rotation step angle with use of a turntable between the linear scans. Thus, CT is carried out by repetition of the linear scanning and the rotation of an object. Penetrating X-ray photons from the object are detected by the CdTe detector, and event signals of X-ray photons are produced with use of charge-sensitive and shaping amplifiers. Both the photon energy and the energy width are selected by use of a multi-channel analyzer, and the number of photons is counted by a counter card. For performing energy discrimination, a low-dose-rate X-ray generator for photon counting was developed; the maximum tube voltage and the minimum tube current were 110 kV and 1.0 microA, respectively. In energy-discrimination CT, the tube voltage and the current were 60 kV and 20.0 microA, respectively, and the X-ray intensity was 0.735 microGy/s at 1.0 m from the source and with a tube voltage of 60 kV. Demonstration of enhanced iodine K-edge X-ray CT was carried out by selection of photons with energies just beyond the iodine K-edge energy of 33.2 keV.
Ma, C; Wang, X; Shao, M; Zhao, L; Jiawei, X; Wu, Z; Wang, H
2015-06-01
Aim of the present study was to investigate the usefulness of 18F-FDG SPECT/CT in differentiated thyroid cancer (DTC) with elevated serum thyroglobulin (Tg) but negative iodine-131 scan. This retrospective review of patients with DTC recurrence who had 18F-FDG SPECT/CT and 18F-FDG PET/CT for elevated serum Tg but negative iodine-131 scan (March 2007-October 2012). After total thyroidectomy followed by radioiodine ablation, 86 consecutive patients with elevated Tg levels underwent 18F-FDG SPECT/CT or 18F-FDG PET/CT. Of these, 45 patients had 18F-FDG SPECT/CT, the other 41 patients had 18F-FDG PET/CT 3-4weeks after thyroid hormone withdrawal. The results of 18F-FDG PET/CT and SPECT/CT were correlated with patient follow-up information, which included the results from subsequent imaging modalities such as neck ultrasound, MRI and CT, Tg levels, and histologic examination of surgical specimens. The diagnostic accuracy of the two imaging modalities was evaluated. In 18F-FDG SPECT/CT scans, 24 (24/45) patients had positive findings, 22 true positive in 24 patients, false positive in 2 patients, true-negative and false-negative in 6, 15 patients, respectively. The overall sensitivity, specificity, and accuracy of 18F-FDG SPECT/CT were 59.5%, 75% and 62.2%, respectively. Twenty six patients had positive findings on 18F-FDG PET/CT scans, 23 true positive in 26 (26/41) patients, false positive in 3 patients, true-negative and false-negative in 9, 6 patients, respectively. The overall sensitivity, specificity, and accuracy of 18F-FDG PET/CT were 79.3%, 81.8% and 78.1%, respectively. Clinical management changed for 13 (29%) of 45 patients by 18F-FDG SPECT/CT, 14 (34%) of 41 patients by 18F-FDG PET/CT including surgery, radiation therapy, or multikinase inhibitor. Based on the retrospective analysis of 86 patients, 18F-FDG SPECT/CT has lower sensitivity in the diagnosis of DTC recurrence with elevated Tg and negative iodine-131scan to 18F-FDG PET/CT. The clinical application of FDG SPECT/CT is then limited and cannot replace PET/CT.
Sethi, A; Rusu, I; Surucu, M; Halama, J
2012-06-01
Evaluate accuracy of multi-modality image registration in radiotherapy planning process. A water-filled anthropomorphic head phantom containing eight 'donut-shaped' fiducial markers (3 internal + 5 external) was selected for this study. Seven image sets (3CTs, 3MRs and PET) of phantom were acquired and fused in a commercial treatment planning system. First, a narrow slice (0.75mm) baseline CT scan was acquired (CT1). Subsequently, the phantom was re-scanned with a coarse slice width = 1.5mm (CT2) and after subjecting phantom to rotation/displacement (CT3). Next, the phantom was scanned in a 1.5 Tesla MR scanner and three MR image sets (axial T1, axial T2, coronal T1) were acquired at 2mm slice width. Finally, the phantom and center of fiducials were doped with 18F and a PET scan was performed with 2mm cubic voxels. All image scans (CT/MR/PET) were fused to the baseline (CT1) data using automated mutual-information based fusion algorithm. Difference between centroids of fiducial markers in various image modalities was used to assess image registration accuracy. CT/CT image registration was superior to CT/MR and CT/PET: average CT/CT fusion error was found to be 0.64 ± 0.14 mm. Corresponding values for CT/MR and CT/PET fusion were 1.33 ± 0.71mm and 1.11 ± 0.37mm. Internal markers near the center of phantom fused better than external markers placed on the phantom surface. This was particularly true for the CT/MR and CT/PET. The inferior quality of external marker fusion indicates possible distortion effects toward the edges of MR image. Peripheral targets in the PET scan may be subject to parallax error caused by depth of interaction of photons in detectors. Current widespread use of multimodality imaging in radiotherapy planning calls for periodic quality assurance of image registration process. Such studies may help improve safety and accuracy in treatment planning. © 2012 American Association of Physicists in Medicine.
Target Volume Delineation in Oropharyngeal Cancer: Impact of PET, MRI, and Physical Examination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thiagarajan, Anuradha, E-mail: anu_thiagarajan@hotmail.com; Caria, Nicola; Schoeder, Heiko
2012-05-01
Introduction: Sole utilization of computed tomography (CT) scans in gross tumor volume (GTV) delineation for head-and-neck cancers is subject to inaccuracies. This study aims to evaluate contributions of magnetic resonance imaging (MRI), positron emission tomography (PET), and physical examination (PE) to GTV delineation in oropharyngeal cancer (OPC). Methods: Forty-one patients with OPC were studied. All underwent contrast-enhanced CT simulation scans (CECTs) that were registered with pretreatment PETs and MRIs. For each patient, three sets of primary and nodal GTV were contoured. First, reference GTVs (GTVref) were contoured by the treating radiation oncologist (RO) using CT, MRI, PET, and PE findings.more » Additional GTVs were created using fused CT/PET scans (GTVctpet) and CT/MRI scans (GTVctmr) by two other ROs blinded to GTVref. To compare GTVs, concordance indices (CI) were calculated by dividing the respective overlap volumes by overall volumes. To evaluate the contribution of PE, composite GTVs derived from CT, MRI, and PET (GTVctpetmr) were compared with GTVref. Results: For primary tumors, GTVref was significantly larger than GTVctpet and GTVctmr (p < 0.001). Although no significant difference in size was noted between GTVctpet and GTVctmr (p = 0.39), there was poor concordance between them (CI = 0.62). In addition, although CI (ctpetmr vs. ref) was low, it was significantly higher than CI (ctpet vs. ref) and CI (ctmr vs. ref) (p < 0.001), suggesting that neither modality should be used alone. Qualitative analyses to explain the low CI (ctpetmr vs. ref) revealed underestimation of mucosal disease when GTV was contoured without knowledge of PE findings. Similar trends were observed for nodal GTVs. However, CI (ctpet vs. ref), CI (ctmr vs. ref), and CI (ctpetmr vs. ref) were high (>0.75), indicating that although the modalities were complementary, the added benefit was small in the context of CECTs. In addition, PE did not aid greatly in nodal GTV delineation. Conclusion: PET and MRI are complementary and combined use is ideal. However, the low CI (ctpetmr vs. ref) particularly for primary tumors underscores the limitations of defining GTVs using imaging alone. PE is invaluable and must be incorporated.« less
Effect of emergency department CT on neuroimaging case volume and positive scan rates.
Oguz, Kader Karli; Yousem, David M; Deluca, Tom; Herskovits, Edward H; Beauchamp, Norman J
2002-09-01
The authors performed this study to determine the effect a computed tomographic (CT) scanner in the emergency department (ED) has on neuroimaging case volume and positive scan rates. The total numbers of ED visits and neuroradiology CT scans requested from the ED were recorded for 1998 and 2000, the years before and after the installation of a CT unit in the ED. For each examination type (brain, face, cervical spine), studies were graded for major findings (those that affected patient care), minor findings, and normal findings. The CT utilization rates and positive study rates were compared for each type of study performed for both years. There was a statistically significant increase in the utilization rate after installation of the CT unit (P < .001). The fractions of studies with major findings, minor findings, and normal findings changed significantly after installation of the CT unit for facial examinations (P = .002) but not for brain (P = .12) or cervical spine (P = .24) examinations. In all types of studies, the percentage of normal examinations increased. In toto, there was a significant decrease in the positive scan rate after installation of the CT scanner (P = .004). After installation of a CT scanner in the ED, there was increased utilization and a decreased rate of positive neuroradiologic examinations, the latter primarily due to lower positive rates for facial CT scans.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, D; Neylon, J; Dou, T
Purpose: A recently proposed 4D-CT protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artifacts, which arise when tissue motion is greater than scan speed. This work identifies the minimum scanner parameters required to successfully generate free-breathing fast-helical scans without doubling-artifacts. Methods: 10 patients were imaged under free breathing conditions 25 times in alternating directions with a 64-slice CT scanner using a low dose fast helical protocol. A high temporal resolution (0.1s) 4D-CT was generated using a patient specific motionmore » model and patient breathing waveforms, and used as the input for a scanner simulation. Forward projections were calculated using helical cone-beam geometry (800 projections per rotation) and a GPU accelerated reconstruction algorithm was implemented. Various CT scanner detector widths and rotation times were simulated, and verified using a motion phantom. Doubling-artifacts were quantified in patient images using structural similarity maps to determine the similarity between axial slices. Results: Increasing amounts of doubling-artifacts were observed with increasing rotation times > 0.2s for 16×1mm slice scan geometry. No significant increase in doubling artifacts was observed for 64×1mm slice scan geometry up to 1.0s rotation time although blurring artifacts were observed >0.6s. Using a 16×1mm slice scan geometry, a rotation time of less than 0.3s (53mm/s scan speed) would be required to produce images of similar quality to a 64×1mm slice scan geometry. Conclusion: The current generation of 16 slice CT scanners, which are present in most Radiation Oncology departments, are not capable of generating free-breathing sorting-artifact-free images in the majority of patients. The next generation of CT scanners should be capable of at least 53mm/s scan speed in order to use a fast-helical 4D-CT protocol to generate a motion-artifact free 4D-CT. NIH R01CA096679.« less
The utility of computed tomography in the management of fever and neutropenia in pediatric oncology.
Rao, Avani D; Sugar, Elizabeth A; Barrett, Neil; Mahesh, Mahadevappa; Arceci, Robert J
2015-10-01
Despite the frequent use and radiation exposure of computed tomography (CT) scans, there is little information on patterns of CT use and their utility in the management of pediatric patients with fever and neutropenia (FN). We examined the contribution of either the commonly employed pan-CT (multiple anatomical locations) or targeted CT (single location) scanning to identify possible infectious etiologies in this challenging clinical scenario. Procedure Pediatric patients with an underlying malignancy admitted for fever (temperature ≥ 38.3 °C) and an absolute neutrophil count <500 cells/μL from 2003-2009 were included. Risk factors associated with utilization, results, and effects on clinical management of CT scans were identified. Results Charts for 635 admissions for FN from 263 patients were reviewed. Overall, 139 (22%) admissions (93 individuals) had at least one scan. Of 188 scans, 103 (55%) were pan-scans. Changes in management were most strongly associated with the identification of evidence consistent with infection (OR = 12.64, 95% CI: 5.05-31.60, P < 0.001). Seventy-eight (41%) of all CT scans led to a change in clinical management, most commonly relating to use of antibiotic (N = 41, 53%) or antifungal/antiviral medications (N = 33, 42%). The odds of a change in clinical management did not differ for those receiving a pan-scan compared to those receiving a targeted scan (OR = 1.23; 95% CI, 0.61-2.46; P = 0.57). Conclusions When CT is clinically indicated, it is important for clinicians to strongly consider utilizing a targeted scan to reduce radiation exposure to patients as well as to decrease costs without compromising care. © 2015 Wiley Periodicals, Inc.
Teymouri, Jessica; Hullar, Timothy E; Holden, Timothy A; Chole, Richard A
2011-08-01
To determine the efficacy of clinical computed tomographic (CT) imaging to verify postoperative electrode array placement in cochlear implant (CI) patients. Nine fresh cadaver heads underwent clinical CT scanning, followed by bilateral CI insertion and postoperative clinical CT scanning. Temporal bones were removed, trimmed, and scanned using micro-CT. Specimens were then dehydrated, embedded in either methyl methacrylate or LR White resin, and sectioned with a diamond wafering saw. Histology sections were examined by 3 blinded observers to determine the position of individual electrodes relative to soft tissue structures within the cochlea. Electrodes were judged to be within the scala tympani, scala vestibuli, or in an intermediate position between scalae. The position of the array could be estimated accurately from clinical CT scans in all specimens using micro-CT and histology as a criterion standard. Verification using micro-CT yielded 97% agreement, and histologic analysis revealed 95% agreement with clinical CT results. A composite, 3-dimensional image derived from a patient's preoperative and postoperative CT images using a clinical scanner accurately estimates the position of the electrode array as determined by micro-CT imaging and histologic analyses. Information obtained using the CT method provides valuable insight into numerous variables of interest to patient performance such as surgical technique, array design, and processor programming and troubleshooting.
Dynamic helical computed tomography of the pituitary gland in healthy dogs.
Van der Vlugt-Meijer, Roselinda H; Meij, Björn P; Voorhout, George
2007-01-01
Dynamic helical computed tomography (CT) of the pituitary gland can be used to image the three-dimensional shape and dimensions of abnormalities within the pituitary gland. The aim of this study was to develop a protocol for dynamic helical CT of the pituitary gland in healthy dogs as a future reference study for patients with pituitary disease. Dynamic helical series of nine scans of the pituitary gland during and following contrast medium injection were performed in six healthy dogs using the following protocols: a series with 1 mm collimation and a table feed per X-ray tube rotation of 2 mm (pitch of 2) in six dogs, a series with 2 mm collimation and pitch of 2 in three dogs, and a series with 1 mm collimation and pitch of 1 in three other dogs. Multiplanar reconstructions of the images were made using a reconstruction index of 0.5. Images of all series were assessed visually for enhancement of the arteries, the neurohypophysis, and the adenohypophysis. The enhancement pattern of the neurohypophysis was distinguished adequately from that of the adenohypophysis in five dogs that were scanned with 1 mm collimation and pitch of 2, but the difference was less discernable when the other protocols were used. The carotid artery, its trifurcation, and the arterial cerebral circle were best visualized in dorsal reconstructions. Dynamic helical CT of the pituitary gland in healthy dogs can be performed with 1 mm collimation and pitch of 2, and a scan length that includes the entire pituitary region. Using this protocol, with the specific scanner used, the neurohypophysis, the adenohypophysis, and the surrounding vascular structures are adequately visualized.
Reducing Head CT Use for Children With Head Injuries in a Community Emergency Department.
Jennings, Rebecca M; Burtner, Jennifer J; Pellicer, Joseph F; Nair, Deepthi K; Bradford, Miranda C; Shaffer, Michele; Uspal, Neil G; Tieder, Joel S
2017-04-01
Clinical decision rules have reduced use of computed tomography (CT) to evaluate minor pediatric head injury in pediatric emergency departments (EDs). CT use remains high in community EDs, where the majority of children seek medical care. We sought to reduce the rate of CT scans used to evaluate pediatric head injury from 29% to 20% in a community ED. We evaluated a quality improvement (QI) project in a community ED aimed at decreasing the use of head CT scans in children by implementing a validated head trauma prediction rule for traumatic brain injury. A multidisciplinary team identified key drivers of CT use and implemented decision aids to improve the use of prediction rules. The team identified and mitigated barriers. An affiliated children's hospital offered Maintenance of Certification credit and QI coaching to participants. We used statistical process control charts to evaluate the effect of the intervention on monthly CT scan rates and performed a Wald test of equivalence to compare preintervention and postintervention CT scan proportions. The baseline period (February 2013-July 2014) included 695 patients with a CT scan rate of 29.2% (95% confidence interval, 25.8%-32.6%). The postintervention period (August 2014-October 2015) included 651 patients with a CT scan rate of 17.4% (95% confidence interval, 14.5%-20.2%, P < .01). Barriers included targeting providers with variable pediatric experience and parental imaging expectations. We demonstrate that a Maintenance of Certification QI project sponsored by a children's hospital can facilitate evidence-based pediatric care and decrease the rate of unnecessary CT use in a community setting. Copyright © 2017 by the American Academy of Pediatrics.
18 F-FDG PET/CT for planning external beam radiotherapy alters therapy in 11% of 581 patients.
Birk Christensen, Charlotte; Loft-Jakobsen, Annika; Munck Af Rosenschöld, Per; Højgaard, Liselotte; Roed, Henrik; Berthelsen, Anne K
2018-03-01
18 F-FDG PET/CT (FDG PET/CT) used in radiotherapy planning for extra-cerebral malignancy may reveal metastases to distant sites that may affect the choice of therapy. To investigate the role of FDG PET/CT on treatment strategy changes induced by the use of PET/CT as part of the radiotherapy planning. 'A major change of treatment strategy' was defined as either including more lesions in the gross tumour volume (GTV) distant from the primary tumour or a change in treatment modalities. The study includes 581 consecutive patients who underwent an FDG PET/CT scan for radiotherapy planning in our institution in the year 2008. All PET/CT scans were performed with the patient in treatment position with the use of immobilization devices according to the intended radiotherapy treatment. All scans were evaluated by a nuclear medicine physician together with a radiologist to delineate PET-positive GTV (GTV-PET). For 63 of the patients (11%), the PET/CT simulation scans resulted in a major change in treatment strategy because of the additional diagnostic information. Changes were most frequently observed in patients with lung cancer (20%) or upper gastrointestinal cancer (12%). In 65% of the patients for whom the PET/CT simulation scan revealed unexpected dissemination, radiotherapy was given - changed (n = 38) or unchanged (n = 13) according to the findings on the FDG PET/CT. Unexpected dissemination on the FDG PET/CT scanning performed for radiotherapy planning caused a change in treatment strategy in 11% of 581 patients. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Yoshikawa, Hiroto; Roback, Donald M; Larue, Susan M; Nolan, Michael W
2015-01-01
Potential benefits of planning radiation therapy on a contrast-enhanced computed tomography scan (ceCT) should be weighed against the possibility that this practice may be associated with an inadvertent risk of overdosing nearby normal tissues. This study investigated the influence of ceCT on intensity-modulated stereotactic body radiotherapy (IM-SBRT) planning. Dogs with head and neck, pelvic, or appendicular tumors were included in this retrospective cross-sectional study. All IM-SBRT plans were constructed on a pre- or ceCT. Contours for tumor and organs at risk (OAR) were manually constructed and copied onto both CT's; IM-SBRT plans were calculated on each CT in a manner that resulted in equal radiation fluence. The maximum and mean doses for OAR, and minimum, maximum, and mean doses for targets were compared. Data were collected from 40 dogs per anatomic site (head and neck, pelvis, and limbs). The average dose difference between minimum, maximum, and mean doses as calculated on pre- and ceCT plans for the gross tumor volume was less than 1% for all anatomic sites. Similarly, the differences between mean and maximum doses for OAR were less than 1%. The difference in dose distribution between plans made on CTs with and without contrast enhancement was tolerable at all treatment sites. Therefore, although caution would be recommended when planning IM-SBRT for tumors near "reservoirs" for contrast media (such as the heart and urinary bladder), findings supported the use of ceCT with this dose calculation algorithm for both target delineation and IM-SBRT treatment planning. © 2015 American College of Veterinary Radiology.
Caroff, J; Mihalea, C; Neki, H; Ruijters, D; Ikka, L; Benachour, N; Moret, J; Spelle, L
2014-07-01
The WEB aneurysm embolization system is still under evaluation but seems to be a promising technique to treat wide-neck bifurcation aneurysms. However, this device is barely visible using conventional DSA; thus, high-resolution contrast-enhanced flat panel detector CT (VasoCT) may be useful before detachment to assess the sizing and positioning of the WEB. The purpose of this study was to evaluate the interest of VasoCT during WEB procedures. From March 2012 to July 2013, twelve patients (10 women and 2 men; age range, 44-55 years) were treated for 13 intracranial aneurysms with the WEB device. DSA and VasoCT were used and compared to depict any protrusion of the device in parent arteries before detachment. Two neuroradiologists reviewed each VasoCT scan, and the quality was graded on a subjective quality scale. The mesh of the WEB was very well-depicted in all cases, allowing a very good assessment of its deployment. Device protrusion was clearly detected with VasoCT in 5 cases, leading to WEB repositioning or size substitution. During follow-up, VasoCT also allows good assessment of eventual residual blood flow inside the aneurysm or the WEB device. Unlike DSA, VasoCT is an excellent tool to assess WEB deployment and positioning. In our experience, it allowed a precise evaluation of the WEB sizing and its relation to the parent vessel. Such information very likely enhances the ability to safely use this device, avoiding potential thromboembolic events in cases of protrusion in the parent arteries. © 2014 by American Journal of Neuroradiology.
Spanier, A B; Caplan, N; Sosna, J; Acar, B; Joskowicz, L
2018-01-01
The goal of medical content-based image retrieval (M-CBIR) is to assist radiologists in the decision-making process by retrieving medical cases similar to a given image. One of the key interests of radiologists is lesions and their annotations, since the patient treatment depends on the lesion diagnosis. Therefore, a key feature of M-CBIR systems is the retrieval of scans with the most similar lesion annotations. To be of value, M-CBIR systems should be fully automatic to handle large case databases. We present a fully automatic end-to-end method for the retrieval of CT scans with similar liver lesion annotations. The input is a database of abdominal CT scans labeled with liver lesions, a query CT scan, and optionally one radiologist-specified lesion annotation of interest. The output is an ordered list of the database CT scans with the most similar liver lesion annotations. The method starts by automatically segmenting the liver in the scan. It then extracts a histogram-based features vector from the segmented region, learns the features' relative importance, and ranks the database scans according to the relative importance measure. The main advantages of our method are that it fully automates the end-to-end querying process, that it uses simple and efficient techniques that are scalable to large datasets, and that it produces quality retrieval results using an unannotated CT scan. Our experimental results on 9 CT queries on a dataset of 41 volumetric CT scans from the 2014 Image CLEF Liver Annotation Task yield an average retrieval accuracy (Normalized Discounted Cumulative Gain index) of 0.77 and 0.84 without/with annotation, respectively. Fully automatic end-to-end retrieval of similar cases based on image information alone, rather that on disease diagnosis, may help radiologists to better diagnose liver lesions.
NASA Astrophysics Data System (ADS)
Bostaph, Ekaterina
This research aimed to study the potential for breaking through object size limitations of current X-ray computed tomography (CT) systems by implementing a limited angle scanning technique. CT stands out among other industrial nondestructive inspection (NDI) methods due to its unique ability to perform 3D volumetric inspection, unmatched micro-focus resolution, and objectivity that allows for automated result interpretation. This work attempts to advance NDI technique to enable microstructural material characterization and structural diagnostics of composite structures, where object sizes often prohibit the application of full 360° CT. Even in situations where the objects can be accommodated within existing micro-CT configuration, achieving sufficient magnification along with full rotation may not be viable. An effort was therefore made to achieve high-resolution scans from projection datasets with limited angular coverage (less than 180°) by developing effective reconstruction algorithms in conjunction with robust scan acquisition procedures. Internal features of inspected objects barely distinguishable in a 2D X-ray radiograph can be enhanced by additional projections that are reconstructed to a stack of slices, dramatically improving depth perception, a technique referred to as digital tomosynthesis. Building on the success of state-of-the-art medical tomosynthesis systems, this work sought to explore the feasibility of this technique for composite structures in aerospace applications. The challenge lies in the fact that the slices generated in medical tomosynthesis are too thick for relevant industrial applications. In order to adapt this concept to composite structures, reconstruction algorithms were expanded by implementation of optimized iterative stochastic methods (capable of reducing noise and refining scan quality) which resulted in better depth perception. The optimal scan acquisition procedure paired with the improved reconstruction algorithm facilitated higher in-plane and depth resolution compared to the clinical application. The developed limited angle tomography technique was demonstrated to be able to detect practically significant manufacturing defects (voids) and structural damage (delaminations) critical to structural integrity of composite parts. Keeping in mind the intended real-world aerospace applications where objects often have virtually unlimited in-plane dimensions, the developed technique of partial scanning could potentially extend the versatility of CT-based inspection and enable game changing NDI systems.
Lee, Eunsol; Goo, Hyun Woo; Lee, Jae-Yeong
2015-08-01
It is necessary to develop a mechanism to estimate and analyze cumulative radiation risks from multiple CT exams in various clinical scenarios in children. To identify major contributors to high cumulative CT dose estimates using actual dose-length product values collected for 5 years in children. Between August 2006 and July 2011 we reviewed 26,937 CT exams in 13,803 children. Among them, we included 931 children (median age 3.5 years, age range 0 days-15 years; M:F = 533:398) who had 5,339 CT exams. Each child underwent at least three CT scans and had accessible radiation dose reports. Dose-length product values were automatically extracted from DICOM files and we used recently updated conversion factors for age, gender, anatomical region and tube voltage to estimate CT radiation dose. We tracked the calculated CT dose estimates to obtain a 5-year cumulative value for each child. The study population was divided into three groups according to the cumulative CT dose estimates: high, ≥30 mSv; moderate, 10-30 mSv; and low, <10 mSv. We reviewed clinical data and CT protocols to identify major contributors to high and moderate cumulative CT dose estimates. Median cumulative CT dose estimate was 5.4 mSv (range 0.5-71.1 mSv), and median number of CT scans was 4 (range 3-36). High cumulative CT dose estimates were most common in children with malignant tumors (57.9%, 11/19). High frequency of CT scans was attributed to high cumulative CT dose estimates in children with ventriculoperitoneal shunt (35 in 1 child) and malignant tumors (range 18-49). Moreover, high-dose CT protocols, such as multiphase abdomen CT (median 4.7 mSv) contributed to high cumulative CT dose estimates even in children with a low number of CT scans. Disease group, number of CT scans, and high-dose CT protocols are major contributors to higher cumulative CT dose estimates in children.
Journy, N; Rehel, J-L; Ducou Le Pointe, H; Lee, C; Brisse, H; Chateil, J-F; Caer-Lorho, S; Laurier, D; Bernier, M-O
2015-01-06
Recent epidemiological results suggested an increase of cancer risk after receiving computed tomography (CT) scans in childhood or adolescence. Their interpretation is questioned due to the lack of information about the reasons for examination. Our objective was to estimate the cancer risk related to childhood CT scans, and examine how cancer-predisposing factors (PFs) affect assessment of the radiation-related risk. The cohort included 67,274 children who had a first scan before the age of 10 years from 2000 to 2010 in 23 French departments. Cumulative X-rays doses were estimated from radiology protocols. Cancer incidence was retrieved through the national registry of childhood cancers; PF from discharge diagnoses. During a mean follow-up of 4 years, 27 cases of tumours of the central nervous system, 25 of leukaemia and 21 of lymphoma were diagnosed; 32% of them among children with PF. Specific patterns of CT exposures were observed according to PFs. Adjustment for PF reduced the excess risk estimates related to cumulative doses from CT scans. No significant excess risk was observed in relation to CT exposures. This study suggests that the indication for examinations, whether suspected cancer or PF management, should be considered to avoid overestimation of the cancer risks associated with CT scans.
Unit Cost Analysis of PET-CT at an Apex Public Sector Health Care Institute in India.
Gajuryal, S H; Daga, A; Siddharth, V; Bal, C S; Satpathy, S
2017-01-01
PET/CT scan service is one of the capital intensive and revenue-generating centres of a tertiary care hospital. The cost associated with the provisioning of PET services is dependent upon the unit costs of the resources consumed. The study aims to determine the cost of providing PET/CT Scan services in a hospital. This descriptive and observational study was conducted in the Department of Nuclear Medicine at a tertiary apex teaching hospital in New Delhi, India in the year 2014-15. Traditional costing methodology was used for calculating the unit cost of PET/CT scan service. The cost was calculated under two heads that is capital and operating cost. Annualized cost of capital assets was calculated using methodology prescribed by WHO and operating costs was taken on an actual basis. Average number of PET/CT scan performed in a day is 30. The annual cost of providing PET/CT scan services was calculated to be 65,311,719 Indian Rupees (INR) (US$ 1,020,496), while the unit cost of PET scan was calculated to be 9625.92 INR (US$ 150). 3/4th cost was spent on machinery and equipment (75.3%) followed by healthcare personnel (11.37%), electricity (5%), consumables and supplies (4%) engineering maintenance (3.24%), building, furniture and HVAC capital cost (0.76%), and manifold cost (0.05%). Of the total cost, 76% was capital cost while the remaining was operating cost. Total cost for establishing PET/CT scan facility with cyclotron and chemistry module and PET/CT scan without cyclotron and chemistry module was calculated to be INR 610,873,517 (US$9944899) and 226,745,158 (US$3542893), respectively. (US$ 1=INR 64).
Livingston, Michael H; Igric, Ana; Vogt, Kelly; Parry, Neil; Merritt, Neil H
2014-01-01
The purpose of this study was to determine the effective dose of radiation due to computed tomography (CT) scans in paediatric trauma patients at a level 1 Canadian paediatric trauma centre. We also explored the indications and actions taken as a result of these scans. We performed a retrospective review of paediatric trauma patients presenting to our centre from January 1, 2007 to December 31, 2008. All CT scans performed during the initial trauma resuscitation, hospital stay, and 6 months afterwards were included. Effective dose was calculated using the reported dose length product for each scan and conversion factors specific for body region and age of the patient. 157 paediatric trauma patients were identified during the 2-year study period. Mean Injury Severity Score was 22.5 (range 12-75). 133 patients received at least one CT scan. The mean number of scans per patient was 2.6 (range 0-16). Most scans resulted in no further action (56%) or additional imaging (32%). A decision to perform a procedure (2%), surgery (8%), or withdrawal of life support (2%) was less common. The average dose per patient was 13.5mSv, which is 4.5 times the background radiation compared to the general population. CT head was the most commonly performed type of scan and was most likely to be repeated. CT body, defined as a scan of the chest, abdomen, and/or pelvis, was associated with the highest effective dose. CT is a significant source of radiation in paediatric trauma patients. Clinicians should carefully consider the indications for each scan, especially when performing non-resuscitation scans. There is a need for evidence-based treatment algorithms to assist clinicians in selecting appropriate imaging for patients with severe multisystem trauma. Copyright © 2013 Elsevier Ltd. All rights reserved.
Skoura, Evangelia; Datseris, Ioannis E; Exarhos, Dimitrios; Chatziioannou, Sophia; Oikonomopoulos, Georgios; Samartzis, Alexandros; Giannopoulou, Chariklia; Syrigos, Konstantinos N
2013-05-01
[ 18 F]fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) has been reported to have a low sensitivity in the initial diagnosis of bronchoalveolar carcinoma (BAC) due to BAC's low metabolic activity. The aim of this study was to assess the value of [ 18 F]FDG-PET/CT in the detection of BAC recurrence. Between February 2007 and September 2011, the [ 18 F]FDG-PET/CT scans that were performed on patients with known, histologically proven BAC were studied. A total of 24 [ 18 F]FDG-PET/CT scans were performed in 22 patients, including 16 males and 6 females, with a mean age of 65±9 years. Among the scans, 15 were performed to assess for possible recurrence with equivocal findings in conventional imaging methods and 9 for restaging post-therapy. In all cases conventional imaging studies (CT and MRI) were performed 5-30 days prior to PET/CT. Among the 24 [ 18 F]FDG-PET/CT scans, 18 were positive and 6 negative. Among the 15 [ 18 F]FDG-PET/CT scans performed for suspected recurrence, 34 lesions were detected and the mean maximum standardized uptake value (SUVmax) was 6.8±3.26. In nine scans, upstaging was observed, while two were in agreement with the findings of the conventional modalities. A greater number of lesions were detected in two scans and fewer lesions were detected in one, with no change in staging. Only one scan was negative. By contrast, in patients examined for restaging, there were only five lesions with a mean SUVmax of 4.86±3.18. Agreement between the findings of [ 18 F]FDG-PET/CT and the conventional modalities was observed in 8 out of 9 cases. Although [ 18 F]FDG-PET/CT has been reported to have a low sensitivity in the initial diagnosis of BAC, the present results indicate that when there is recurrence, the lesions become [ 18 F]FDG avid. [ 18 F]FDG-PET/CT may provide further information in patients evaluated for recurrence and thus improve patient management.
NASA Astrophysics Data System (ADS)
Stantz, Keith M.; Liu, Bo; Cao, Minsong; Reinecke, Dan; Dzemidzic, Mario; Liang, Yun; Kruger, Robert
2006-03-01
Purpose: To evaluate photoacoustic CT spectroscopy (PCT-S) and dynamic contrast-enhanced CT (DCE-CT) ability to measure parameters - oxygen saturation and vascular physiology - associated with the intra-tumor oxygenation status. Material and Methods: Breast (VEGF165 enhance MCF-7) and ovarian (SKOV3x) cancer cells were implanted into the fat pads and flanks of immune deficient mice and allowed to grow to a diameter of 8-15 mm. CT was used to determine physiological parameters by acquiring a sequence of scans over a 10 minute period after an i.v. injection of a radio-opaque contrast agent (Isovue). These time-dependent contrast-enhanced curves were fit to a two-compartmental model determining tumor perfusion, fractional plasma volume, permeability-surface area produce, and fractional interstitial volume on a voxel-by-voxel basis. After which, the tumors were imaged using photoacoustic CT (Optosonics, Inc., Indianapolis, IN 46202). The near infrared spectra (700-910 nm) within the vasculature was fit to linear combination of measured oxy- and deoxy-hemoglobin blood samples to obtain oxygen saturation levels (SaO II). Results: The PCT-S scanner was first calibrated using different samples of oxygenated blood, from which a statistical error ranging from 2.5-6.5% was measured and a plot of the hemoglobin dissociation curve was consistent with empirical formula. In vivo determination of tumor vasculature SaO II levels were measurably tracked, and spatially correlated to the periphery of the tumor. Tumor depend variations in SaO II - 0.32 (ovarian) and 0.60 (breast) - and in vascular physiology - perfusion, 1.03 and 0.063 mL/min/mL, and fractional plasma volume, 0.20 and 0.07 - were observed. Conclusion: Combined, PCT-S and CED-CT has the potential to measure intra-tumor levels of tumor oxygen saturation and vascular physiology, key parameters associated with hypoxia.
Sierink, Joanne C; Treskes, Kaij; Edwards, Michael J R; Beuker, Benn J A; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G W; Luitse, Jan S K; Beenen, Ludo F M; Hollmann, Markus W; Goslings, J Carel
2016-08-13
Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in patients with trauma. We undertook an international, multicentre, randomised controlled trial at four hospitals in the Netherlands and one in Switzerland. Patients aged 18 years or older with trauma with compromised vital parameters, clinical suspicion of life-threatening injuries, or severe injury were randomly assigned (1:1) by ALEA randomisation to immediate total-body CT scanning or to a standard work-up with conventional imaging supplemented with selective CT scanning. Neither doctors nor patients were masked to treatment allocation. The primary endpoint was in-hospital mortality, analysed in the intention-to-treat population and in subgroups of patients with polytrauma and those with traumatic brain injury. The χ(2) test was used to assess differences in mortality. This trial is registered with ClinicalTrials.gov, number NCT01523626. Between April 22, 2011, and Jan 1, 2014, 5475 patients were assessed for eligibility, 1403 of whom were randomly assigned: 702 to immediate total-body CT scanning and 701 to the standard work-up. 541 patients in the immediate total-body CT scanning group and 542 in the standard work-up group were included in the primary analysis. In-hospital mortality did not differ between groups (total-body CT 86 [16%] of 541 vs standard work-up 85 [16%] of 542; p=0.92). In-hospital mortality also did not differ between groups in subgroup analyses in patients with polytrauma (total-body CT 81 [22%] of 362 vs standard work-up 82 [25%] of 331; p=0.46) and traumatic brain injury (68 [38%] of 178 vs 66 [44%] of 151; p=0.31). Three serious adverse events were reported in patients in the total-body CT group (1%), one in the standard work-up group (<1%), and one in a patient who was excluded after random allocation. All five patients died. Diagnosing patients with an immediate total-body CT scan does not reduce in-hospital mortality compared with the standard radiological work-up. Because of the increased radiation dose, future research should focus on the selection of patients who will benefit from immediate total-body CT. ZonMw, the Netherlands Organisation for Health Research and Development. Copyright © 2016 Elsevier Ltd. All rights reserved.
Investigating different computed tomography techniques for internal target volume definition.
Yoganathan, S A; Maria Das, K J; Subramanian, V Siva; Raj, D Gowtham; Agarwal, Arpita; Kumar, Shaleen
2017-01-01
The aim of this work was to evaluate the various computed tomography (CT) techniques such as fast CT, slow CT, breath-hold (BH) CT, full-fan cone beam CT (FF-CBCT), half-fan CBCT (HF-CBCT), and average CT for delineation of internal target volume (ITV). In addition, these ITVs were compared against four-dimensional CT (4DCT) ITVs. Three-dimensional target motion was simulated using dynamic thorax phantom with target insert of diameter 3 cm for ten respiration data. CT images were acquired using a commercially available multislice CT scanner, and the CBCT images were acquired using On-Board-Imager. Average CT was generated by averaging 10 phases of 4DCT. ITVs were delineated for each CT by contouring the volume of the target ball; 4DCT ITVs were generated by merging all 10 phases target volumes. Incase of BH-CT, ITV was derived by boolean of CT phases 0%, 50%, and fast CT target volumes. ITVs determined by all CT and CBCT scans were significantly smaller (P < 0.05) than the 4DCT ITV, whereas there was no significant difference between average CT and 4DCT ITVs (P = 0.17). Fast CT had the maximum deviation (-46.1% ± 20.9%) followed by slow CT (-34.3% ± 11.0%) and FF-CBCT scans (-26.3% ± 8.7%). However, HF-CBCT scans (-12.9% ± 4.4%) and BH-CT scans (-11.1% ± 8.5%) resulted in almost similar deviation. On the contrary, average CT had the least deviation (-4.7% ± 9.8%). When comparing with 4DCT, all the CT techniques underestimated ITV. In the absence of 4DCT, the HF-CBCT target volumes with appropriate margin may be a reasonable approach for defining the ITV.
Ghaghada, Ketan B; Sato, Amy F; Starosolski, Zbigniew A; Berg, John; Vail, David M
2016-01-01
Companion dogs with naturally occurring cancer serve as an important large animal model in translational research because they share strong similarities with human cancers. In this study, we investigated a long circulating liposomal-iodine contrast agent (Liposomal-I) for computed tomography (CT) imaging of solid tumors in companion dogs with naturally occurring cancer. The institutional animal ethics committees approved the study and written informed consent was obtained from all owners. Thirteen dogs (mean age 10.1 years) with a variety of masses including primary and metastatic liver tumors, sarcomas, mammary carcinoma and lung tumors, were enrolled in the study. CT imaging was performed pre-contrast and at 15 minutes and 24 hours after intravenous administration of Liposomal-I (275 mg/kg iodine dose). Conventional contrast-enhanced CT imaging was performed in a subset of dogs, 90 minutes prior to administration of Liposomal-I. Histologic or cytologic diagnosis was obtained for each dog prior to admission into the study. Liposomal-I resulted in significant (p < 0.05) enhancement and uniform opacification of the vascular compartment. Non-renal, reticulo-endothelial systemic clearance of the contrast agent was demonstrated. Liposomal-I enabled visualization of primary and metastatic liver tumors. Sub-cm sized liver lesions grossly appeared as hypo-enhanced compared to the surrounding normal parenchyma with improved lesion conspicuity in the post-24 hour scan. Large liver tumors (> 1 cm) demonstrated a heterogeneous pattern of intra-tumoral signal with visibly higher signal enhancement at the post-24 hour time point. Extra-hepatic, extra-splenic tumors, including histiocytic sarcoma, anaplastic sarcoma, mammary carcinoma and lung tumors, were visualized with a heterogeneous enhancement pattern in the post-24 hour scan. The long circulating liposomal-iodine contrast agent enabled prolonged visualization of small and large tumors in companion dogs with naturally occurring cancer. The study warrants future work to assess the sensitivity and specificity of the Liposomal-I agent in various types of naturally occurring canine tumors.
Human identification based on cranial computed tomography scan — a case report
Silva, RF; Botelho, TL; Prado, FB; Kawagushi, JT; Daruge Júnior, E; Bérzin, F
2011-01-01
Today, there is increasing use of CT scanning on a clinical basis, aiding in the diagnosis of diseases or injuries. This exam also provides important information that allows identification of individuals. This paper reports the use of a CT scan on the skull, taken when the victim was alive, for the positive identification of a victim of a traffic accident in which the fingerprint analysis was impossible. The authors emphasize that the CT scan is a tool primarily used in clinical diagnosis and may contribute significantly to forensic purpose, allowing the exploration of virtual corpses before the classic autopsy. The use of CT scans might increase the quantity and quality of information involved in the death of the person examined. PMID:21493883
CT scans in young people in Northern England: trends and patterns 1993–2002
Pearce, Mark S.; Salotti, Jane A.; McHugh, Kieran; Metcalf, Wenhua; Kim, Kwang P.; Craft, Alan W.; Parker, Louise; Ron, Elaine
2014-01-01
Background Although CT can be greatly beneficial, its relatively high radiation doses have caused public health concerns. Objective To assess patterns in CT usage among patients aged less than 22 years in Northern England during the period 1993–2002. Materials and methods Electronic data were obtained from radiology information systems of all nine National Health Service trusts in the region. Results A total of 38,681 scans had been performed in 20,483 patients aged less than 22 years. The number of CT examinations rose, with the steepest increase between 1997 and 2000. The number of patients scanned per year increased less dramatically, with 2.24/1,000 population aged less than 22 years having one scan or more in 1993 compared to 3.54/1,000 in 2002. This reflects an increase in the median number of scans per patient, which rose from 1 in 1993 to 2 by 1999. More than 70% of CT examinations were of the head, with the number of head examinations varying with time and patient age. Conclusion The frequency of CT scans in this population more than doubled during the study period. This is partly, but not wholly, explained by an increase in the number of scans per patient. PMID:21594548
Wang, Zhen J.; Chen, Katherine S.; Gould, Robert; Coakley, Fergus V.; Fu, Yanjun; Yeh, Benjamin M.
2014-01-01
Objective To assess the effect of positive enteric contrast administration on automatic exposure control (AEC) CT radiation exposure in 1) a CT phantom, and 2) a retrospective review of patients. Materials and Methods We scanned a CT phantom containing simulated bowel that was sequentially filled with water and positive enteric contrast, and recorded the mean volume CT dose index (CTDIvol). We also identified 17 patients who had undergone 2 technically comparable CT scans of the abdomen and pelvis, one with positive enteric contrast and the other with oral water. Paired student t-tests were used to compare the mean CTDIvol between scans performed with and without positive enteric contrast. Both the phantom and patient CT scans were performed using AEC with a fixed noise index. Results The mean CTDIvol for the phantom with simulated bowel containing water and positive enteric contrast were 8.2 ± 0.2 mGy, and 8.7 ± 0.1 mGy (6.1% higher than water, p=0.02), respectively. The mean CTDIvol for patients scanned with oral water and with positive enteric contrast were 11.8mGy and 13.1mGy, respectively (p=0.003). This corresponded to a mean CTDIvol which was 11.0% higher (range: 0.0–20.7% higher) in scans with positive enteric contrast than those with oral water in patients. Conclusions When automatic exposure control is utilized for abdominopelvic CT, the radiation exposure, as measured by CTDIvol, is higher for scans performed with positive enteric contrast than those with oral water. PMID:21493028
Is appendiceal CT scan overused for evaluating patients with right lower quadrant pain?
Safran, D B; Pilati, D; Folz, E; Oller, D
2001-05-01
Reports citing excellent sensitivity, specificity, and predictive accuracy of focused appendiceal computed tomography (CT) and showing an overall reduction in resource use and nontherapeutic laparotomies have led to increasing use of that imaging modality. Diagnostic algorithms have begun to incorporate appendiceal CT for patients presenting to the emergency department with right lower quadrant pain. We present a series of 4 cases in which use of appendiceal CT ultimately led to increased cost, resource use, and complexity in patient care. The results of these cases support an argument against unbridled use of appendiceal CT scanning and reinforce the need for clinical evaluation by the operating surgeon before routine performance of appendiceal CT scan.
Effect of topogram-tube angle combination on CT radiation dose reduction
NASA Astrophysics Data System (ADS)
Shim, J.; Yoon, M.
2017-09-01
This study assessed the ability of various types of topograms, when used with an automatic tube current modulation (ATCM) technique, to reduce radiation dose from computed tomography (CT) scans. Three types of topograms were used with the ATCM technique: (i) anteroposterior (AP) topograms alone, (ii) AP topograms followed by lateral topograms, and (iii) lateral topograms followed by AP topograms. Various regions (chest, abdomen and whole-body) of a humanoid phantom were scanned at several tube voltages (80, 100 and 120 kVp) with the selected topograms. Although the CT dose depended on the order of topograms, the CT dose with respect to patient positioning depended on the number of topograms performed. The magnitude of the difference in CT dose between number and order of topograms was greater for the scans of the abdomen than the chest. These results suggest that, for the Siemens SOMATOM Definition AS CT scanner, choosing the right combination of CT scan conditions with the ATCM technique can minimize radiation dose to a patient.
Mathews, John D; Forsythe, Anna V; Brady, Zoe; Butler, Martin W; Goergen, Stacy K; Byrnes, Graham B; Giles, Graham G; Wallace, Anthony B; Anderson, Philip R; Guiver, Tenniel A; McGale, Paul; Cain, Timothy M; Dowty, James G; Bickerstaffe, Adrian C; Darby, Sarah C
2013-05-21
To assess the cancer risk in children and adolescents following exposure to low dose ionising radiation from diagnostic computed tomography (CT) scans. Population based, cohort, data linkage study in Australia. COHORT MEMBERS: 10.9 million people identified from Australian Medicare records, aged 0-19 years on 1 January 1985 or born between 1 January 1985 and 31 December 2005; all exposures to CT scans funded by Medicare during 1985-2005 were identified for this cohort. Cancers diagnosed in cohort members up to 31 December 2007 were obtained through linkage to national cancer records. Cancer incidence rates in individuals exposed to a CT scan more than one year before any cancer diagnosis, compared with cancer incidence rates in unexposed individuals. 60,674 cancers were recorded, including 3150 in 680,211 people exposed to a CT scan at least one year before any cancer diagnosis. The mean duration of follow-up after exposure was 9.5 years. Overall cancer incidence was 24% greater for exposed than for unexposed people, after accounting for age, sex, and year of birth (incidence rate ratio (IRR) 1.24 (95% confidence interval 1.20 to 1.29); P<0.001). We saw a dose-response relation, and the IRR increased by 0.16 (0.13 to 0.19) for each additional CT scan. The IRR was greater after exposure at younger ages (P<0.001 for trend). At 1-4, 5-9, 10-14, and 15 or more years since first exposure, IRRs were 1.35 (1.25 to 1.45), 1.25 (1.17 to 1.34), 1.14 (1.06 to 1.22), and 1.24 (1.14 to 1.34), respectively. The IRR increased significantly for many types of solid cancer (digestive organs, melanoma, soft tissue, female genital, urinary tract, brain, and thyroid); leukaemia, myelodysplasia, and some other lymphoid cancers. There was an excess of 608 cancers in people exposed to CT scans (147 brain, 356 other solid, 48 leukaemia or myelodysplasia, and 57 other lymphoid). The absolute excess incidence rate for all cancers combined was 9.38 per 100,000 person years at risk, as of 31 December 2007. The average effective radiation dose per scan was estimated as 4.5 mSv. The increased incidence of cancer after CT scan exposure in this cohort was mostly due to irradiation. Because the cancer excess was still continuing at the end of follow-up, the eventual lifetime risk from CT scans cannot yet be determined. Radiation doses from contemporary CT scans are likely to be lower than those in 1985-2005, but some increase in cancer risk is still likely from current scans. Future CT scans should be limited to situations where there is a definite clinical indication, with every scan optimised to provide a diagnostic CT image at the lowest possible radiation dose.
Lange, Jeffrey; Karellas, Andrew; Street, John; Eck, Jason C; Lapinsky, Anthony; Connolly, Patrick J; Dipaola, Christian P
2013-03-01
Observational. To estimate the radiation dose imparted to patients during typical thoracolumbar spinal surgical scenarios. Minimally invasive techniques continue to become more common in spine surgery. Computer-assisted navigation systems coupled with intraoperative cone-beam computed tomography (CT) represent one such method used to aid in instrumented spinal procedures. Some studies indicate that cone-beam CT technology delivers a relatively low dose of radiation to patients compared with other x-ray-based imaging modalities. The goal of this study was to estimate the radiation exposure to the patient imparted during typical posterior thoracolumbar instrumented spinal procedures, using intraoperative cone-beam CT and to place these values in the context of standard CT doses. Cone-beam CT scans were obtained using Medtronic O-arm (Medtronic, Minneapolis, MN). Thermoluminescence dosimeters were placed in a linear array on a foam-plastic thoracolumbar spine model centered above the radiation source for O-arm presets of lumbar scans for small or large patients. In-air dosimeter measurements were converted to skin surface measurements, using published conversion factors. Dose-length product was calculated from these values. Effective dose was estimated using published effective dose to dose-length product conversion factors. Calculated dosages for many full-length procedures using the small-patient setting fell within the range of published effective doses of abdominal CT scans (1-31 mSv). Calculated dosages for many full-length procedures using the large-patient setting fell within the range of published effective doses of abdominal CT scans when the number of scans did not exceed 3. We have demonstrated that single cone-beam CT scans and most full-length posterior instrumented spinal procedures using O-arm in standard mode would likely impart a radiation dose within the range of those imparted by a single standard CT scan of the abdomen. Radiation dose increases with patient size, and the radiation dose received by larger patients as a result of more than 3 O-arm scans in standard mode may exceed the dose received during standard CT of the abdomen. Understanding radiation imparted to patients by cone-beam CT is important for assessing risks and benefits of this technology, especially when spinal surgical procedures require multiple intraoperative scans.
Zhang, Dongxia; Gan, Yangzhou; Xiong, Jing; Xia, Zeyang
2017-02-01
Complete three-dimensional(3D) tooth model provides essential information to assist orthodontists for diagnosis and treatment planning. Currently, 3D tooth model is mainly obtained by segmentation and reconstruction from dental computed tomography(CT) images. However, the accuracy of 3D tooth model reconstructed from dental CT images is low and not applicable for invisalign design. And another serious problem also occurs, i.e. frequentative dental CT scan during different intervals of orthodontic treatment often leads to radiation to the patients. Hence, this paper proposed a method to reconstruct tooth model based on fusion of dental CT images and laser-scanned images. A complete3 D tooth model was reconstructed with the registration and fusion between the root reconstructed from dental CT images and the crown reconstructed from laser-scanned images. The crown of the complete 3D tooth model reconstructed with the proposed method has higher accuracy. Moreover, in order to reconstruct complete 3D tooth model of each orthodontic treatment interval, only one pre-treatment CT scan is needed and in the orthodontic treatment process only the laser-scan is required. Therefore, radiation to the patients can be reduced significantly.
Single energy micro CT SkyScan 1173 for the characterization of urinary stone
NASA Astrophysics Data System (ADS)
Fitri, L. A.; Asyana, V.; Ridwan, T.; Anwary, F.; Soekersi, H.; Latief, F. D. E.; Haryanto, F.
2016-08-01
A urinary stone is a solid piece of material produced from crystallization of excreted substances in the urine. Knowledge of the composition of urinary stones is essential to determine the suitable treatment for the patient. The aim of this research was to characterize urinary stones using single energy micro CT SkyScan 1173. Six human urinary stones were scanned in vitro using 80 kV in micro CT SkyScan 1173. The produced projection, images, were reconstructed using NRecon (in-house software from SkyScan). The images of urinary stones were analyzed using CT Analyser (CT An) to obtain information of the internal structure and the Hounsfield Unit (HU) value to determine the information regarding the composition of the urinary stones, respectively. The average HU values from certain region of interests in the same slice were compared with spectral curves of known materials from National Institute of Standards and Technology (NIST). From the analysis, the composition of the six scanned stones were obtained. Two stones are composed of cystine, two are composed of struvite, two other stones are composed of struvite+cystine. In conclusion, the single energy micro CT with 80 kV can be used identifying cystine and struvite urinary stone.
Spindle epithelial tumor with thymus-like differentiation of the thyroid in a 70-year-old man.
Lee, Sunhye; Kim, Yon Seon; Lee, Jeong Hyeon; Hwang, Sung Ho; Oh, Yu-Hwan; Ko, Byung Kyun; Ham, Soo-Youn
2018-06-01
Spindle epithelial tumor with thymus-like differentiation (SETTLE) is a very rare tumor of the thyroid gland mostly occurring in young patients. The imaging findings of SETTLE tumors are yet to be defined. However, they are usually described as well-defined heterogeneously enhanced masses on CT scan. The current case has the potential growth as compared with a 2009 chest radiography. We took into account the possibility of SETTLE in the case of a bulky mass in patients over 70 years old, particularly in the lower neck. Herein, we report a case of the oldest patient so far. The patient underwent a right lobectomy of the thyroid and mass excision. Follow-up CT scans after 6 months revealed no local recurrence. Surgery is the gold standard treatment for SETTLE. Chemotherapy and radiotherapy could be another possible option for patients with advanced stage SETTLE.
Gandhi, Rohit; Lewis, Evan Cole; Evans, Jeanette W; Sell, Erick
2015-03-01
Headaches are a common problem in the pediatric population. In 2002, the American Academy of Neurology (AAN) developed guidelines on neuroimaging for patients presenting with headache. Our objective was to determine the frequency of computed tomographic (CT) scanning ordered by a range of medical practitioners for pediatric patients presenting with primary headache. A retrospective chart review was conducted at the Children's Hospital of Eastern Ontario (CHEO), a tertiary care centre in Ontario. One hundred fifty-one records of patients referred to the outpatient neurology clinic at CHEO with ''headache'' or ''migraine'' as the primary complaint from 2004 to 2009 were randomly selected. Ninety-nine patients with normal neurologic examinations were ultimately included. Thirty-four patients (34%; 95% CI 25-45) had undergone CT scanning. None of the 34 CT scans (0%; 95% CI 0-10) showed significant findings, and none changed the headache diagnosis or management. Eleven (32%) of the CT scans were ordered by CHEO neurologists, 15 (44%) by community physicians, and 8 (24%) by CHEO emergency physicians. A high proportion of children presenting with primary headaches and a normal neurologic examination undergo CT scanning, despite well-established AAN guidelines regarding neuroimaging. Most of these CT scans do not appear to alter diagnosis and management. A variety of non-evidencebased factors may be encouraging physicians to overinvestigate this population and, as a result, increasing the risk of adverse events due to radiation exposure. Implementing initiatives at a site-based level that promote the use of established guidelines before performing CT scanning in this population may be beneficial.
Rapalino, O; Kamalian, Shervin; Kamalian, Shahmir; Payabvash, S; Souza, L C S; Zhang, D; Mukta, J; Sahani, D V; Lev, M H; Pomerantz, S R
2012-04-01
To safeguard patient health, there is great interest in CT radiation-dose reduction. The purpose of this study was to evaluate the impact of an iterative-reconstruction algorithm, ASIR, on image-quality measures in reduced-dose head CT scans for adult patients. Using a 64-section scanner, we analyzed 100 reduced-dose adult head CT scans at 6 predefined levels of ASIR blended with FBP reconstruction. These scans were compared with 50 CT scans previously obtained at a higher routine dose without ASIR reconstruction. SNR and CNR were computed from Hounsfield unit measurements of normal GM and WM of brain parenchyma. A blinded qualitative analysis was performed in 10 lower-dose CT datasets compared with higher-dose ones without ASIR. Phantom data analysis was also performed. Lower-dose scans without ASIR had significantly lower mean GM and WM SNR (P = .003) and similar GM-WM CNR values compared with higher routine-dose scans. However, at ASIR levels of 20%-40%, there was no statistically significant difference in SNR, and at ASIR levels of ≥60%, the SNR values of the reduced-dose scans were significantly higher (P < .01). CNR values were also significantly higher at ASIR levels of ≥40% (P < .01). Blinded qualitative review demonstrated significant improvements in perceived image noise, artifacts, and GM-WM differentiation at ASIR levels ≥60% (P < .01). These results demonstrate that the use of ASIR in adult head CT scans reduces image noise and increases low-contrast resolution, while allowing lower radiation doses without affecting spatial resolution.
Impact of low-energy CT imaging on selection of positive oral contrast media concentration.
Patino, Manuel; Murcia, Diana J; Iamurri, Andrea Prochowski; Kambadakone, Avinash R; Hahn, Peter F; Sahani, Dushyant V
2017-05-01
To determine to what extent low-energy CT imaging affects attenuation of gastrointestinal tract (GIT) opacified with positive oral contrast media (OCM). Second, to establish optimal OCM concentrations for low-energy diagnostic CT exams. One hundred patients (38 men and 62 women; age 62 ± 11 years; BMI 26 ± 5) with positive OCM-enhanced 120-kVp single-energy CT (SECT), and follow-up 100-kVp acquisitions (group A; n = 50), or 40-70-keV reconstructions from rapid kV switching-single-source dual-energy CT (ssDECT) (group B; n = 50) were included. Luminal attenuation from different GIT segments was compared between exams. Standard dose of three OCM and diluted solutions (75%, 50%, and 25% concentrations) were introduced serially in a gastrointestinal phantom and scanned using SECT (120, 100, and 80 kVp) and DECT (80/140 kVp) acquisitions on a ssDECT scanner. Luminal attenuation was obtained on SECT and DECT images (40-70 keV), and compared to 120-kVp scans with standard OCM concentrations. Luminal attenuation was higher on 100-kVp (328 HU) and on 40-60-keV images (410-924 HU) in comparison to 120-kVp scans (298 HU) in groups A and B (p < 0.05). Phantom: There was an inverse correlation between luminal attenuation and X-ray energy, increasing up to 527 HU on low-kVp and 999 HU on low-keV images (p < 0.05). 25% and 50% diluted OCM solutions provided similar or higher attenuation than 120 kVp, at low kVp and keV, respectively. Low-energy CT imaging increases the attenuation of GIT opacified with positive OCM, permitting reduction of 25%-75% OCM concentration.
TU-F-18A-06: Dual Energy CT Using One Full Scan and a Second Scan with Very Few Projections
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, T; Zhu, L
Purpose: The conventional dual energy CT (DECT) requires two full CT scans at different energy levels, resulting in dose increase as well as imaging errors from patient motion between the two scans. To shorten the scan time of DECT and thus overcome these drawbacks, we propose a new DECT algorithm using one full scan and a second scan with very few projections by preserving structural information. Methods: We first reconstruct a CT image on the full scan using a standard filtered-backprojection (FBP) algorithm. We then use a compressed sensing (CS) based iterative algorithm on the second scan for reconstruction frommore » very few projections. The edges extracted from the first scan are used as weights in the Objectives: function of the CS-based reconstruction to substantially improve the image quality of CT reconstruction. The basis material images are then obtained by an iterative image-domain decomposition method and an electron density map is finally calculated. The proposed method is evaluated on phantoms. Results: On the Catphan 600 phantom, the CT reconstruction mean error using the proposed method on 20 and 5 projections are 4.76% and 5.02%, respectively. Compared with conventional iterative reconstruction, the proposed edge weighting preserves object structures and achieves a better spatial resolution. With basis materials of Iodine and Teflon, our method on 20 projections obtains similar quality of decomposed material images compared with FBP on a full scan and the mean error of electron density in the selected regions of interest is 0.29%. Conclusion: We propose an effective method for reducing projections and therefore scan time in DECT. We show that a full scan plus a 20-projection scan are sufficient to provide DECT images and electron density with similar quality compared with two full scans. Our future work includes more phantom studies to validate the performance of our method.« less
Kobe, Isaac O; Qureshi, Mahmoud M; Hassan, Saidi; Oluoch-Olunya, David L
2017-12-01
The decision to order head CT scans to rule out clinically significant traumatic brain injury in mild head injury in children is made on the basis of clinical decision rules of which the Paediatric Emergency Care Applied Research Network (PECARN) CT head rules have been found to be most sensitive. The purpose of this study is to determine the proportion of head CT scans done for children with mild head injury and to determine disposition of patients from casualty after the introduction of PECARN head CT rules compared to the period before. The research question is "will introduction of the PECARN CT head rules reduce the proportion of head CT scans requested for children under 18 years with mild head injury at the AKUHN?" A before and after quasi experimental study with a study population including all children under 18 years presenting to the AKUHN with mild head injury and a Glasgow coma scale of 14 and above on presentation. Sample size was 85. A total of 42 patients files were analysed in the before study while 43 patients were selected for the after study. The median age was 5 years. The proportion of head CT scans reduced from 56% in the before group to 33% in the after group with no missed clinically significant traumatic brain injury. More patients were discharged home after evaluation in the after group (81%) than in the before group (58%). The number of head CT scans ordered reduced without missing any clinically significant traumatic brain injury.
[Exposure to CT scans in childhood and long-term cancer risk: A review of epidemiological studies].
Baysson, Hélène; Journy, Neige; Roué, Tristan; Ducou-Lepointe, Hubert; Etard, Cécile; Bernier, Marie-Odile
2016-02-01
Amongst medical exams requiring ionizing radiation, computed tomography (CT) scans are used more frequently, including in children. These CT examinations are associated with absorbed doses that are much higher than those associated with conventional radiology. In comparison to adults, children have a greater sensitivity to radiation and a longer life span with more years at cancer risks. Five epidemiological studies on cancer risks after CT scan exposure during childhood were published between 2012 and 2015. The results of these studies are consistent and show an increase of cancer risks in children who have been exposed to several CT scans. However, methodological limits due to indication bias, retrospective assessment of radiation exposure from CT scans and lack of statistical power are to be taken into consideration. International projects such as EPI-CT (Epidemiological study to quantify risks for pediatric computerized tomography and to optimize dose), with a focus on dosimetric reconstruction and minimization of bias will provide more precise results. In the meantime, available results reinforce the necessity of justification and optimization of doses. Copyright © 2015 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.
Liu, Yiyan
Focal lung uptake without corresponding lesions or abnormalities on computed tomography (CT) scan poses a dilemma in the interpretation of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). A limited number of case reports have previously suggested an artifactual or iatrogenic nature of the uptake. In the present study, 8 relevant cases were included within a retrospective search of the database. Medical records were reviewed for follow-up radiological and pathologic information. In 7 of 8 cases with focal increased FDG uptake but no corresponding lesions or abnormalities on CT scan, the lung hot spots were artifactual or iatrogenic upon follow-up diagnostic chest CT or repeated PET/CT or both the scans. Microemboli were most likely a potential cause of the pulmonary uptake, with or without partial paravenous injection. One case in the series had a real pulmonary lesion demonstrated on follow-up PET/CT scans and on surgical pathology, although the initial integrated CT and follow-up diagnostic chest CT scans revealed negative findings to demonstrate pulmonary abnormalities corresponding to the hot spot on the PET scan. In conclusion, the finding of a lung hot spot in the absence of anatomical abnormality on FDG PET/CT was most likely artifactual or iatrogenic, but it might also represent a real pulmonary lesion. Nonvisualization of anatomical abnormality could be because of its small size and position directly overlying a segmental vessel. Further image follow-up is necessary and important to clarify the nature of the uptake. Copyright © 2017 Elsevier Inc. All rights reserved.
Journal Club: Head CT scans in the emergency department for syncope and dizziness.
Mitsunaga, Myles M; Yoon, Hyo-Chun
2015-01-01
The purpose of this study was to determine the yield of acutely abnormal findings on head CT scans in patients presenting to the emergency department with dizziness, near-syncope, or syncope and to determine the clinical factors that potentially predicted acutely abnormal head CT findings and hospital admission. We retrospectively reviewed the electronic medical records of all patients presenting to an HMO emergency department between July 1, 2012, and December 31, 2012, who underwent head CT for a primary complaint of dizziness, syncope, or near-syncope. The primary outcomes were head CT scans with acutely abnormal findings and hospital admission. Binary logistic regression was used to assess the association between clinical variables and acute head CT findings and between clinical variables and hospital admission. Of the 253 patients who presented with dizziness, 7.1% had head CT scans with acutely abnormal findings, and 18.6% were admitted. Of the 236 patients who presented with syncope or near-syncope, 6.4% had head CT scans with acutely abnormal findings, and 39.8% were admitted. The following three clinical factors were found to be significantly correlated with acutely abnormal head CT findings: a focal neurologic deficit (p = 0.003), age greater than 60 years (p = 0.011), and acute head trauma (p = 0.026). Our results suggest that most patients presenting with syncope or dizziness to the emergency department may not benefit from head CT unless they are older, have a focal neurologic deficit, or have a history of recent head trauma.
Chen, Alexander; Pastis, Nicholas; Furukawa, Brian; Silvestri, Gerard A
2015-05-01
Electromagnetic navigation has improved the diagnostic yield of peripheral bronchoscopy for pulmonary nodules. For these procedures, a thin-slice chest CT scan is performed prior to bronchoscopy at full inspiration and is used to create virtual airway reconstructions that are used as a map during bronchoscopy. Movement of the lung occurs with respiratory variation during bronchoscopy, and the location of pulmonary nodules during procedures may differ significantly from their location on the initial planning full-inspiratory chest CT scan. This study was performed to quantify pulmonary nodule movement from full inspiration to end-exhalation during tidal volume breathing in patients undergoing electromagnetic navigation procedures. A retrospective review of electromagnetic navigation procedures was performed for which two preprocedure CT scans were performed prior to bronchoscopy. One CT scan was performed at full inspiration, and a second CT scan was performed at end-exhalation during tidal volume breathing. Pulmonary lesions were identified on both CT scans, and distances between positions were recorded. Eighty-five pulmonary lesions were identified in 46 patients. Average motion of all pulmonary lesions was 17.6 mm. Pulmonary lesions located in the lower lobes moved significantly more than upper lobe nodules. Size and distance from the pleura did not significantly impact movement. Significant movement of pulmonary lesions occurs between full inspiration and end-exhalation during tidal volume breathing. This movement from full inspiration on planning chest CT scan to tidal volume breathing during bronchoscopy may significantly affect the diagnostic yield of electromagnetic navigation bronchoscopy procedures.
Firoozabadi, Razieh Dehghani; Karimi Zarchi, Mojgan; Mansurian, Hamid Reza; Moghadam, Bita Rafiei; Teimoori, Soraya; Naseri, Ali
2011-01-01
Because benign and malignant cervical and ovarian masses occur with different percentages in different age groups, the importance of primary diagnosis and selection of a suitable surgical procedure is underlined. Diagnosis of pelvic masses is carried out using ultrasound, physical examination, CT scan and MRI. The objective of this study is to evaluate the diagnostic value of CT scan in pelvic masses in comparison with physical examination-ultrasound based on pathology of the lesion in patients undergoing laparotomic surgery. This analytic-descriptive study focused on age, sonographic findings, physical examinations, CT scan and pathological findings in 139 patients with pelvic mass, gathered with questionnaires and statistically analayzed using the SPSS software programme. Of 139 patients with pelvic mass (patients aged from 17 to 75 years old), 62 (44%) cases were diagnosed as benign and 77 (55.4%) as malignant; among them malignant tratoma serocyst adenocarsinoma with 33 (23.7%) cases and benign myoma with 21 (15.2%) cases comprised the most frequent cases. The sensitivity and specificity of sonography-physical examination were 51.9% and 87.9% respectively and the sensitivity and specificity of CT scan images were 79.2% and 91.6% respectively. It was shown that CT scan images were more consistant with pathological findings in predicting appropriate surgical procedures than do sonography-physical examinations. The sensitivity of CT scan is far higher than that of sonography-physical examination in the diagnosis of pelvic mass malignancy.
Asha, Stephen Edward; Cooke, Andrew
2015-09-01
Suspected body packers may be brought to emergency departments (EDs) close to international airports for abdominal computed tomography (CT) scanning. Senior emergency clinicians may be asked to interpret these CT scans. Missing concealed drug packages have important clinical and forensic implications. The accuracy of emergency clinician interpretation of abdominal CT scans for concealed drugs is not known. Limited evidence suggests that accuracy for identification of concealed packages can be increased by viewing CT images on "lung window" settings. To determine the accuracy of senior emergency clinicians in interpreting abdominal CT scans for concealed drugs, and to determine if this accuracy was improved by viewing scans on both abdominal and lung window settings. Emergency clinicians blinded to all patient identifiers and the radiology report interpreted CT scans of suspected body packers using standard abdominal window settings and then with the addition of lung window settings. The reference standard was the radiologist's report. Fifty-five emergency clinicians reported 235 CT scans. The sensitivity, specificity, and accuracy of interpretation using abdominal windows was 89.9% (95% confidence interval [CI] 83.0-94.7), 81.9% (95% CI 73.7-88.4), and 86.0% (95% CI 81.5-90.4), respectively, and with both window settings was 94.1% (95% CI 88.3-97.6), 76.7% (95% CI 68.0-84.1), 85.5% (95% CI 81.0-90.0), respectively. Diagnostic accuracy was similar regardless of the clinician's experience. Interrater reliability was moderate (kappa 0.46). The accuracy of interpretation of abdominal CT scans performed for the purpose of detecting concealed drug packages by emergency clinicians is not high enough to safely discharge these patients from the ED. The use of lung windows improved sensitivity, but at the expense of specificity. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.
Tan, Ker-Kan; Liu, Jody Zhiyang; Go, Tsung-Shyen; Vijayan, Appasamy; Chiu, Ming-Terk
2010-05-01
Computed tomographic (CT) scans have become invaluable in the management of patients with blunt abdominal trauma. No clear consensus exists on its role in hollow viscus injuries (HVI) and mesenteric injuries (MI). The aim of this study was to correlate operative findings of HVI and MI to findings on pre-operative CT. All patients treated for blunt abdominal trauma at Tan Tock Seng Hospital from January 2003 to January 2008 were reviewed. CT scans were only performed if the patients were haemodynamically stable and indicated. All scans were performed with intravenous contrast using a 4-slice CT scanner from 2003 to December 2004 and a 64-slice CT scanner from January 2005 onwards. All cases with documented HVI/MI that underwent both CT scans and exploratory laparotomy were analysed. Thirty-one patients formed the study group, with median age of 40 (range, 22-65) years and a significant male (83.9%) predominance. Vehicular-related incidents accounted for 67.7% of the injuries and the median Injury Severity Score (ISS) was 13 (4-50). The 2 commonest findings on CT scans were extra-luminal gas (35.5%) and free fluid without significant solid organ injuries (93.5%). During exploratory laparotomy, perforation of hollow viscus (51.6%) occurred more frequently than suspected from the initial CT findings of extra-luminal gas. Other notable findings included haemoperitoneum (64.5%), and mesenteric tears (67.7%). None of our patients with HVI and MI had a normal pre-operative CT scan. Our study suggests that patients with surgically confirmed HVI and MI found at laparotomy were very likely to have an abnormal pre-operative CT scan. Unexplained free fluid was a very common finding in blunt HVI/MI and is one major indication to consider exploratory laparotomy. (c) 2009 Elsevier Ltd. All rights reserved.
[Mobile CT: technical aspects of prehospital stroke imaging before intravenous thrombolysis].
Gierhake, D; Weber, J E; Villringer, K; Ebinger, M; Audebert, H J; Fiebach, J B
2013-01-01
To reduce the time from symptom onset to treatment with tissue plasminogen activator (tPA) in ischemic stroke, an ambulance was equipped with a CT scanner. We analyzed process and image quality of CT scanning during the pilot study regarding image quality and safety issues. The pilot study of a stroke emergency mobile unit (STEMO) ran over a period of 12 weeks on 5 weekdays from 7a.m. to 6:30 p.m. A teleradiological service for the justifying indication and reporting was established. The radiographer was responsible for the performance of the CT scan on the ambulance. 64 cranial CT scans and 1 intracranial CT angiography were performed. We compared times from ambulance alarm to treatment decision (time of last brain scan) with a cohort of 50 consecutive tPA treatments before implementation of STEMO. 62 (95%) of the 65 scans performed had sufficient quality for reading. Technical quality was not optimal in 45 cases (69%) mainly caused by suboptimal positioning of patient or eye lens protection. Motion artefacts were observed in 8 exams (12%). No safety issues occurred for team or patients. 23 patients were treated with thrombolysis. Time from alarm to last CT scan was 18 minutes shorter than in the tPA cohort before STEMO implementation. A teleradiological support for primary stroke imaging by CT on-site is feasible, quality-wise of diagnostic value and has not raised safety issues. © Georg Thieme Verlag KG Stuttgart · New York.
Selecting a CT scanner for cardiac imaging: the heart of the matter.
Lewis, Maria A; Pascoal, Ana; Keevil, Stephen F; Lewis, Cornelius A
2016-09-01
Coronary angiography to assess the presence and degree of arterial stenosis is an examination now routinely performed on CT scanners. Although developments in CT technology over recent years have made great strides in improving the diagnostic accuracy of this technique, patients with certain characteristics can still be "difficult to image". The various groups will benefit from different technological enhancements depending on the type of challenge they present. Good temporal and spatial resolution, wide longitudinal (z-axis) detector coverage and high X-ray output are the key requirements of a successful CT coronary angiography (CTCA) scan. The requirement for optimal patient dose is a given. The different scanner models recommended for CTCA all excel in different aspects. The specification data presented here for these scanners and the explanation of the impact of the different features should help in making a more informed decision when selecting a scanner for CTCA.
CT biliary cystoscopy of gallbladder polyps
Lou, Ming-Wu; Hu, Wei-Dong; Fan, Yi; Chen, Jin-Hua; E, Zhan-Sen; Yang, Guang-Fu
2004-01-01
AIM: CT virtual endoscopy has been used in the study of various organs of body including the biliary tract, however, CT virtual endoseopy in diagnosis of gallbladder polyps has not yet been reported. This study was to evaluate the diagnostic value of CT virtual endoscopy in polyps of the gallbladder. METHODS: Thirty-two cases of gallbladder polyps were examined by CT virtual endoscopy, ultrasound, CT scan with oral biliary contrast separately and confirmed by operation and pathology. CT biliary cystoscopic findings were analyzed and compared with those of ultrasound and CT scan with oral biliary contrast, and evaluated in comparison with operative and pathologic findings in all cases. RESULTS: The detection rate of gallbladder polyps was 93.8%(90/96), 96.9%(93/96) and 79.2%(76/96) for CT cystoscopy, ultrasound and CT scan with oral contrast, respectively. CT biliary cystoscopy corresponded well with ultrasound as well as pathology in demonstrating the location, size and configuration of polyps. CT endoscopy was superior to ultrasound in viewing the polyps in a more precise way, 3 dimensionally from any angle in space, and showing the surface in details. CT biliary cystoscopy was also superior to CT scan with oral biliary contrast in terms of observation of the base of polyps for the presence of a pedicle, detection rates as well as image quality. The smallest polyp detected by CT biliary cystoscopy was measured 1.5 mm×2.2 mm×2.5 mm. CONCLUSION: CT biliary cystoscopy is a non-invasive and accurate technique for diagnosis and management of gallbladder polyps. PMID:15069726
Kuo, Ling-Wei; Yang, Shang-Ju; Fu, Chih-Yuan; Liao, Chien-Hung; Wang, Shang-Yu; Wu, Shih-Chi
2016-01-01
In the evaluation of haemorrhage in trauma patients with pelvic fractures, contrast extravasation (CE) on computed tomography (CT) scan often implies active arterial bleeding. However, the absence of CE on CT scan does not always exclude the need for transcatheter arterial embolisation (TAE) to achieve haemostasis. In the current study, we evaluated the factors associated with the need for TAE in patients without CE on CT scan. These factors may be evaluated as adjuncts to CT scanning in the management of patients with pelvic fractures. We retrospectively reviewed our trauma registry and medical records of patients with pelvic fractures. When CE was observed, indicating active haemorrhage, the patients underwent TAE to achieve haemostasis. In contrast, patients without CE were held for observation and treatment of their injuries, and if their condition deteriorated after a delayed interval, they were then also referred for TAE if no other focus of haemorrhage was found. Patients without CE on CT scan but with retroperitoneal haemorrhage requiring TAE were investigated. Their demographic characteristics, associated injuries, fracture patterns, and changes in systolic blood pressure were described and analysed. In total, 201 patients with pelvic fracture underwent CT scan examination; 47 (23.4%) had CE by CT scan, whereas the other 154 (76.6%) did not. Of the 154 patients who did not show CE by CT scan, 124 (80.5%) patients never underwent TAE; however, 30 (19.5%) of these patients did eventually undergo TAE. In comparing the patients who underwent TAE to those who did not undergo TAE among patients without CE on CT scan, the systolic blood pressure (SBP) on arrival (median: 100.0 mmHg vs 136.0 mmHg, p<0.01) and the lowest SBP recorded in the ED (median: 68.0 mmHg vs 129.0 mmHg, p<0.01) were significantly lower in the patients who underwent TAE. The ROC curve analysis revealed that the most appropriate cutoff value of decrement of SBP (SBP on arrival minus the lowest SBP in the ED) was 30 mmHg (AUC=0.89). In the management of pelvic fracture patients, greater attention should be directed toward patients with relative hypotension. The higher likelihood of haemodynamic deterioration and the need for TAE for haemorrhage control should remain under consideration in such cases, despite the absence of CE by CT scan. Copyright © 2015 Elsevier Ltd. All rights reserved.
Near-Infrared Spectroscopy: A Promising Prehospital Tool for Management of Traumatic Brain Injury.
Peters, Joost; Van Wageningen, Bas; Hoogerwerf, Nico; Tan, Edward
2017-08-01
Introduction Early identification of traumatic brain injury (TBI) is essential. Near-infrared spectroscopy (NIRS) can be used in prehospital settings for non-invasive monitoring and the diagnosis of patients who may require surgical intervention. The handheld NIRS Infrascanner (InfraScan Inc.; Philadelphia, Pennsylvania USA) uses eight symmetrical scan points to detect intracranial bleeding. A scanner was tested in a physician-staffed helicopter Emergency Medical Service (HEMS). The results were compared with those obtained using in-hospital computed tomography (CT) scans. Scan time, ease-of-use, and change in treatment were scored. A total of 25 patients were included. Complete scans were performed in 60% of patients. In 15 patients, the scan was abnormal, and in one patient, the scan resulted in a treatment change. Compared with the results of CT scanning, the Infrascanner obtained a sensitivity of 93.3% and a specificity of 78.6%. Most patients had severe TBI with indication for transport to a trauma center prior to scanning. In one patient, the scan resulted in a treatment change. Evaluation of patients with less severe TBI is needed to support the usefulness of the Infrascanner as a prehospital triage tool. Promising results were obtained using the InfraScan NIRS device in prehospital screening for intracranial hematomas in TBI patients. High sensitivity and good specificity were found. Further research is necessary to determine the beneficial effects of enhanced prehospital screening on triage, survival, and quality of life in TBI patients. Peters J , Van Wageningen B , Hoogerwerf N , Tan E . Near-infrared spectroscopy: a promising prehospital tool for management of traumatic brain injury. Prehosp Disaster Med. 2017;32(4):414-418.
Giovanella, Luca; Trimboli, Pierpaolo; Verburg, Frederik A; Treglia, Giorgio; Piccardo, Arnoldo; Foppiani, Luca; Ceriani, Luca
2013-06-01
To assess the relationship between serum thyroglobulin (Tg) levels, Tg doubling time (Tg-DT) and the diagnostic performance of (18)F-FDG PET/CT in detecting recurrences of (131)I-negative differentiated thyroid carcinoma (DTC). Included in the present study were 102 patients with DTC. All patients were treated by thyroid ablation (e.g. thyroidectomy and (131)I), and underwent (18)F-FDG PET/CT due to detectable Tg levels and negative conventional imaging. Consecutive serum Tg measurements performed before the (18)F-FDG PET/CT examination were used for Tg-DT calculation. The (18)F-FDG PET/CT results were assessed as true or false after histological and/or clinical follow-up. Serum Tg levels were higher in patients with a positive (18)F-FDG PET/CT scan (median 6.7 ng/mL, range 0.7-73.6 ng/mL) than in patients with a negative scan (median 1.8 ng/mL, range 0.5-4.9 ng/mL; P < 0.001). In 43 (88 %) of 49 patients with a true-positive (18)F-FDG PET/CT scan, the Tg levels were >5.5 ng/mL, and in 31 (74 %) of 42 patients with a true-negative (18)F-FDG PET/CT scan, the Tg levels were ≤5.5 ng/mL. A Tg-DT of <1 year was found in 46 of 49 patients (94 %) with a true-positive (18)F-FDG PET/CT scan, and 40 of 42 patients (95 %) with a true-negative scan had a stable or increased Tg-DT. Moreover, combining Tg levels and Tg-DT as selection criteria correctly distinguished between patients with a positive and a negative scan (P<0.0001). The accuracy of (18)F-FDG PET/CT significantly improves when the serum Tg level is above 5.5 ng/mL during levothyroxine treatment or when the Tg-DT is less than 1 year, independent of the absolute value.
Wong, Andrew C; Kowalenko, Terry; Roahen-Harrison, Stephanie; Smith, Barbara; Maio, Ronald F; Stanley, Rachel M
2011-03-01
The objective of the study was to determine whether fear of malpractice is associated with emergency physicians' decision to order head computed tomography (CT) in 3 age-specific scenarios of pediatric minor head trauma. We hypothesized that physicians with higher fear of malpractice scores will be more likely to order head CT scans. Board-eligible/board-certified members of the Michigan College of Emergency Physicians were sent a 2-part survey consisting of case scenarios and demographic questions. Effect of fear of malpractice on the decision to order a CT scan was evaluated using a cumulative logit model. Two hundred forty-six members (36.5%) completed the surveys. In scenario 1 (infant), being a male and working in a university setting were associated with reduced odds of ordering a CT scan (odds ratio [OR], 0.40; 95% confidence interval [CI], 0.18-0.88; and OR, 0.35; 95% CI, 0.13-0.96, respectively). In scenario 2 (toddler), working for 15 years or more, at multiple hospitals, and for a private group were associated with reduced odds of ordering a CT scan (OR, 0.46; 95% CI, 0.26-0.79; OR, 0.36; 95% CI, 0.16-0.80; and OR, 0.51; 95% CI, 0.27-0.94, respectively). No demographic variables were significantly associated with ordering a CT scan in scenario 3 (teen). Overall, the fear of malpractice was not significantly associated with ordering a CT scan (OR, 1.28; 95% CI, 0.73-2.26; and OR, 1.70; 95% CI, 0.97-3.0). Only in scenario 2 was high fear significantly associated with increased odds of ordering a CT scan (OR, 2.09; 95% CI, 1.08-4.05). Members of Michigan College of Emergency Physicians with a higher fear of malpractice score tended to order more head CT scans in pediatric minor head trauma. However, this trend was shown to be statistically significant only in 1 case and not overall.
Journy, N; Rehel, J-L; Ducou Le Pointe, H; Lee, C; Brisse, H; Chateil, J-F; Caer-Lorho, S; Laurier, D; Bernier, M-O
2015-01-01
Background: Recent epidemiological results suggested an increase of cancer risk after receiving computed tomography (CT) scans in childhood or adolescence. Their interpretation is questioned due to the lack of information about the reasons for examination. Our objective was to estimate the cancer risk related to childhood CT scans, and examine how cancer-predisposing factors (PFs) affect assessment of the radiation-related risk. Methods: The cohort included 67 274 children who had a first scan before the age of 10 years from 2000 to 2010 in 23 French departments. Cumulative X-rays doses were estimated from radiology protocols. Cancer incidence was retrieved through the national registry of childhood cancers; PF from discharge diagnoses. Results: During a mean follow-up of 4 years, 27 cases of tumours of the central nervous system, 25 of leukaemia and 21 of lymphoma were diagnosed; 32% of them among children with PF. Specific patterns of CT exposures were observed according to PFs. Adjustment for PF reduced the excess risk estimates related to cumulative doses from CT scans. No significant excess risk was observed in relation to CT exposures. Conclusions: This study suggests that the indication for examinations, whether suspected cancer or PF management, should be considered to avoid overestimation of the cancer risks associated with CT scans. PMID:25314057
The presurgical workup before third molar surgery: how much is enough?
Better, Hadar; Abramovitz, Itzhak; Shlomi, Biniamin; Kahn, Adrian; Levy, Yaakov; Shaham, Amit; Chaushu, Gavriel
2004-06-01
We sought to assess the indications for patient referral for computed tomography (CT) scan before third molar extraction. The influence of the data obtained from the CT scans on the surgical outcome and morbidity was also evaluated. There were 189 patients in the study (120 females and 69 males). Sixty-five patients were referred to receive CT and formed the study group. The remaining patients were included in the control group. There were no statistically significant differences between the groups with regard to demographic data and tooth and root angulations. Indications for tooth extraction such as pain, swelling, pericoronitis, caries, endodontic problems, pathology, and prosthetic considerations were similar. The proximity of the tooth root to the inferior alveolar canal was the only statistically significant difference between the 2 groups (P <.001). The treatment plan outcomes for extraction, surgical extraction, and follow-up were comparable. The surgeon changed the initial decision from "surgical extraction" to "follow-up" in only 1 case after CT scan. Within the limits of the present study, it can be concluded that the main reason for CT scan referral is the proximity of the third molar root to the inferior alveolar canal (<1 mm). The data obtained from the CT scan had minimal effect on the final surgical outcome. The routine use of CT scan in cases of third molar extractions cannot be recommended.
Sigler, Eric J; Randolph, John C
2013-09-19
To compare macular choroidal thickness between patients older than 65 years with early atrophic age-related macular degeneration (AMD) and normals. This was a consecutive, cross-sectional observational study. Enhanced depth imaging spectral-domain optical coherence tomography using horizontal raster scanning at 12 locations throughout the macula was performed in one eye of consecutive patients presenting with large soft drusen alone, drusen with additional features of early AMD, or a normal fundus. Choroidal thickness was measured at 7 points for each raster scan in the central 3 mm of the macula (total 84 points per eye). In addition, a single subfoveolar measurement was obtained for each eye. One hundred fifty eyes of 150 patients were included. There was no significant difference between mean refractive error for each diagnosis category via one-way ANOVA (P = 0.451). Mean macular choroidal thickness (CT) was 235 ± 49 μm (range, 125-334 μm; median 222 μm) for normals, 161 ± 39 μm (range, 89-260 μm; median = 158 μm) for the drusen group, and 115 ± 40 μm (range, 22-256 μm; median = 112 μm) for patients with AMD. Mean macular CT was significantly different via one-way ANOVA among all diagnosis categories (P < 0.001). The presence of features of early AMD without geographic atrophy and/or soft drusen alone is associated with decreased mean macular CT in vivo compared to that in patients with no chorioretinal pathology. Using enhanced depth imaging, measurement of a single subfoveolar choroidal thickness is highly correlated to mean central macular CT.
Das, K; Biswas, S; Roughley, S; Bhojak, M; Niven, S
2014-03-01
To describe a cerebral computed tomography angiography (CTA) technique using a 320-detector CT machine and a small contrast medium volume (35 ml, 15 ml for test bolus). Also, to compare the quality of these images with that of the images acquired using a larger contrast medium volume (90 or 120 ml) and a fixed time delay (FTD) of 18 s using a 16-detector CT machine. Cerebral CTA images were acquired using a 320-detector machine by synchronizing the scanning time with the time of peak enhancement as determined from the time-density curve (TDC) using a test bolus dose. The quality of CTA images acquired using this technique was compared with that obtained using a FTD of 18 s (by 16-detector CT), retrospectively. Average densities in four different intracranial arteries, overall opacification of arteries, and the degree of venous contamination were graded and compared. Thirty-eight patients were scanned using the TDC technique and 40 patients using the FTD technique. The arterial densities achieved by the TDC technique were higher (significant for supraclinoid and basilar arteries, p < 0.05). The proportion of images deemed as having "good" arterial opacification was 95% for TDC and 90% for FTD. The degree of venous contamination was significantly higher in images produced by the FTD technique (p < 0.001%). Good diagnostic quality CTA images with significant reduction of venous contamination can be achieved with a low contrast medium dose using a 320-detector machine by coupling the time of data acquisition with the time of peak enhancement. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Mild brain injury and anticoagulants: Less is enough.
Campiglio, Laura; Bianchi, Francesca; Cattalini, Claudio; Belvedere, Daniela; Rosci, Chiara Emilia; Casellato, Chiara Livia; Secchi, Manuela; Saetti, Maria Cristina; Baratelli, Elena; Innocenti, Alessandro; Cova, Ilaria; Gambini, Chiara; Romano, Luca; Oggioni, Gaia; Pagani, Rossella; Gardinali, Marco; Priori, Alberto
2017-08-01
Despite the higher theoretical risk of traumatic intracranial hemorrhage (ICH) in anticoagulated patients with mild head injury, the value of sequential head CT scans to identify bleeding remains controversial. This study evaluated the utility of 2 sequential CT scans at a 48-hour interval (CT1 and CT2) in patients with mild head trauma (Glasgow Coma Scale 13-15) taking oral anticoagulants. We retrospectively evaluated the clinical records of all patients on chronic anticoagulation treatment admitted to the emergency department for mild head injury. A total of 344 patients were included, and 337 (97.9%) had a negative CT1. CT2 was performed on 284 of the 337 patients with a negative CT1 and was positive in 4 patients (1.4%), but none of the patients developed concomitant neurologic worsening or required neurosurgery. Systematic routine use of a second CT scan in mild head trauma in patients taking anticoagulants is expensive and clinically unnecessary.
Childhood CT scans linked to leukemia and brain cancer later in life
Children and young adults scanned multiple times by computed tomography (CT), a commonly used diagnostic tool, have a small increased risk of leukemia and brain tumors in the decade following their first scan.
Tek Chand, Kalawat; Chennu, Krishna Kishore; Amancharla Yadagiri, Lakshmi; Manthri Gupta, Ranadheer; Rapur, Ram; Vishnubotla, Siva Kumar
2017-04-01
Studies on fever of unknown origin (FUO) in patients of chronic kidney disease and end stage renal disease patients on dialysis were not many. In this study, we used 18 F-FDG PET/CT scan whole body survey for detection of hidden infection, in patients on dialysis, labelled as FUO. In this retrospective study, 20 patients of end stage renal disease on dialysis were investigated for the cause of FUO using 18F-FDG PET/CT scan. All these patients satisfied the definition of FUO as defined by Petersdorf and Beeson. Any focal abnormal site of increased FDG concentration detected by PET/CT, either a solitary or multiple lesions was documented and at least one of the detected abnormal sites of radio tracer concentration was further examined for histopathology. All patients were on renal replacement therapy. Of these, 18 were on hemodialysis and two were on peritoneal dialysis. 18F-FDG PET/CT scan showed metabolically active lesions in 15 patients and metabolically quiescent in five patients. After 18F-FDG PET/CT scan all, but one patient had a change in treatment for fever. Anti-tuberculous treatment was given in 15 patients, antibiotics in four patients and anti-malaria treatment in one patient. The present study is first study of 18F-FDG PET/CT scan in patients of end stage renal disease on dialysis with FUO. The study showed that the 18 F FDG PET/CT scan may present an opportunity to attain the diagnosis in end stage renal disease patients on dialysis with FUO. © 2016 International Society for Hemodialysis.
Avoiding CT scans in children with single-suture craniosynostosis.
Schweitzer, T; Böhm, H; Meyer-Marcotty, P; Collmann, H; Ernestus, R-I; Krauß, J
2012-07-01
During the last decades, computed tomography (CT) has become the predominant imaging technique in the diagnosis of craniosynostosis. In most craniofacial centers, at least one three-dimensional (3D) computed tomographic scan is obtained in every case of suspected craniosynostosis. However, with regard to the risk of radiation exposure particularly in young infants, CT scanning and even plain radiography should be indicated extremely carefully. Our current diagnostic protocol in the management of single-suture craniosynostosis is mainly based on careful clinical examination with regard to severity and degree of the abnormality and on ophthalmoscopic surveillance. Imaging techniques consist of ultrasound examination in young infants while routine plain radiographs are usually postponed to the date of surgery or the end of the first year. CT and magnetic resonance imaging (MRI) are confined to special diagnostic problems rarely encountered in isolated craniosynostosis. The results of this approach were evaluated retrospectively in 137 infants who were referred to our outpatient clinic for evaluation and/or treatment of suspected single suture craniosynostosis or positional deformity during a 2-year period (2008-2009). In 133 (97.1%) of the 137 infants, the diagnosis of single-suture craniosynostosis (n = 110) or positional plagiocephaly (n = 27) was achieved through clinical analysis only. Two further cases were classified by ultrasound, while the remaining two cases needed additional digital radiographs. In no case was CT scanning retrospectively considered necessary for establishing the diagnosis. Yet in 17.6% of cases, a cranial CT scan had already been performed elsewhere (n = 16) or had been definitely scheduled (n = 8). CT scanning is rarely necessary for evaluation of single-suture craniosynostosis. Taking into account that there is a quantifiable risk of developing cancer in further lifetime, every single CT scan should be carefully indicated.
Nishiyama, Yuichi; Kanayama, Hidekazu; Mori, Hiroshi; Tada, Keiji; Yamamoto, Yasushi; Katsube, Takashi; Takeshita, Haruo; Kawakami, Kazunori; Kitagaki, Hajime
2017-06-01
This study examined the usefulness of statistical parametric mapping (SPM) for investigating postmortem changes on brain computed tomography (CT). This retrospective study included 128 patients (23 - 100 years old) without cerebral abnormalities who underwent unenhanced brain CT before and after death. The antemortem CT (AMCT) scans and postmortem CT (PMCT) scans were spatially normalized using our original brain CT template, and postmortem changes of CT values (in Hounsfield units; HU) were analysed by the SPM technique. Compared with AMCT scans, 58.6 % and 98.4 % of PMCT scans showed loss of the cerebral sulci and an unclear grey matter (GM)-white matter (WM) interface, respectively. SPM analysis revealed a significant decrease in cortical GM density within 70 min after death on PMCT scans, suggesting cytotoxic brain oedema. Furthermore, there was a significant increase in the density of the WM, lenticular nucleus and thalamus more than 120 min after death. The SPM technique demonstrated typical postmortem changes on brain CT scans, and revealed that the unclear GM-WM interface on early PMCT scans is caused by a rapid decrease in cortical GM density combined with a delayed increase in WM density. SPM may be useful for assessment of whole brain postmortem changes. • The original brain CT template achieved successful normalization of brain morphology. • Postmortem changes in the brain were independent of sex. • Cortical GM density decreased rapidly after death. • WM and deep GM densities increased following cortical GM density change. • SPM could be useful for assessment of whole brain postmortem changes.
Paediatric blunt abdominal trauma - are we doing too many computed tomography scans?
Arnold, M; Moore, S W
2013-02-14
Blunt abdominal trauma in childhood contributes significantly to both morbidity and mortality. Selective non-operative management of blunt abdominal trauma in children depends on both diagnostic and clinical factors. Computed tomography (CT) scanning is widely used to facilitate better management. Increased availability of CT may, however, result in its overuse in the management of blunt abdominal trauma in children, which carries significant radiation exposure risks. To evaluate the use and value of CT scanning in the overall management and outcome of blunt abdominal trauma in children in the Tygerberg Academic Hospital trauma unit, Parow, Cape Town, South Africa, before and after improved access to CT as a result of installation of a new rapid CT scanner in the trauma management area (previously the scanner had been 4 floors away). Patients aged 0 - 13 years who were referred with blunt abdominal trauma due to vehicle-related accidents before the introduction of the new CT scanner (group 1, n=66, November 2003 - March 2009) were compared with those seen in the 1-year period after the scanner was installed (group 2, n=37, April 2009 - April 2010). Details of clinical presentation, imaging results and their influence on management were retrospectively reviewed. A follow-up group was evaluated after stricter criteria for abdominal CT scanning (viz. prior evaluation by paediatric surgical personnel) were introduced (group 3, n=14, November 2011 - May 2012) to evaluate the impact of this clinical screening on the rate of negative scans. There were 66 patients in group 1 and 37 in group 2. An apparent increase in CT use with increased availability was accompanied by a marked increase in negative CT scans (38.9% compared with 6.2%; p<0.006). Despite a slightly higher prevalence of associated injuries in group 2, as well as a slightly longer length of hospital stay, there was a similar prevalence of intra-abdominal injuries detected in positive scans in the two groups. In addition, rates of small-bowel perforation in the two groups were similar. The rate of negative scans in group 3 was 46.2% (6/13), but all except one of these patients had a severe brain injury preventing adequate clinical evaluation of intra-abdominal injury. CT scanning for blunt abdominal trauma in children is essential in the presence of appropriate clinical indications. Ease of access probably increases availability, but the rate of negative scans may increase. Management guidelines should be in place to direct CT scanning to cases in which clinical examination and/or other modalities indicate a likelihood of intra-abdominal injury. The principle of 'as low (radiation) dose as reasonably achievable' (ALARA) should be adhered to because of the increased radiation exposure risks in children.
Hybrid SPECT-CT and PET-CT imaging of differentiated thyroid carcinoma.
Wong, K K; Zarzhevsky, N; Cahill, J M; Frey, K A; Avram, A M
2009-10-01
Hybrid imaging modalities such as radioiodine single photon emission CT with integrated CT ((131)I SPECT-CT) and 2-(fluorine-18)-fluoro-2-deoxy-D-glucose positron emission tomography with integrated CT (FDG PET-CT) allow the rapid and efficient fusion of functional and anatomic images, and provide diagnostic information that may influence management decisions in patients with differentiated thyroid carcinoma (DTC). Diagnostic localisation and therapy of these tumours are dependent upon their capacity to concentrate radioiodine ((131)I) via uptake through the sodium-iodide symporter and retention within the tumour. The prognosis for most patients with DTC is favourable, although controversy exists regarding the role of post-operative (131)I therapy in patients at low-risk for disease. Accurate identification of functional thyroid tissue (benign or malignant) using diagnostic (131)I planar scintigraphy complemented by SPECT-CT imaging enables the completion of post-operative staging and patient risk stratification prior to (131)I therapy administration. In patients with non-iodine-avid tumours (negative (131)I scan but elevated thyroglobulin indicative of persistent or recurrent disease), FDG PET-CT is used to identify tumours with enhanced glucose metabolism and to localise the source of thyroglobulin production. The CT component of this hybrid technology provides anatomic localisation of activity and allows CT-based attenuation correction of PET images. Images from 15 patients illustrate the applications of (131)I SPECT-CT and FDG PET-CT.
Han, Sung-Mi; Chikawa, Jun-Ichi; Jeon, Jae-Kun; Hwang, Min-Young; Lim, Jun; Jeong, Young-Ju; Park, Sung-Hwan; Kim, Hong-Tae; Jheon, Sanghoon; Kim, Jong-Ki
2016-01-01
Nanoscopic synchrotron X-ray imaging was performed on scalp hair samples of patients with breast cancer and healthy individuals to investigate any structural differences as diagnostic tool. Hair strands were divided into 2-3 segments along the strands from root to tip, followed by imaging either in projection or in CT scanning with a monochromatic 6.78-keV X-ray using zone-plate optics with a resolving power of 60 nm. All the examined cancer hairs exhibited medulla loss with cancer stage-dependent pattern; complete loss, discontinuous or trace along the strands. In contrast, medullas were well retained without complete loss in the healthy hair. In the CT-scanned axial images, the cortical spindle compartments had no contrast in the healthy hair, but appeared hypointense in contrast to the surrounding hyperintense cortical membrane complex in the cancer hair. In conclusion, observation of medulla loss and cortical membrane enhancements in the hair strands of breast cancer patients demonstrated structural variations in the cancer hair, providing a new platform for further synchrotron X-ray imaging study of screening breast cancer patients. © 2015 Wiley Periodicals, Inc.
Algorithm-enabled partial-angular-scan configurations for dual-energy CT.
Chen, Buxin; Zhang, Zheng; Xia, Dan; Sidky, Emil Y; Pan, Xiaochuan
2018-05-01
We seek to investigate an optimization-based one-step method for image reconstruction that explicitly compensates for nonlinear spectral response (i.e., the beam-hardening effect) in dual-energy CT, to investigate the feasibility of the one-step method for enabling two dual-energy partial-angular-scan configurations, referred to as the short- and half-scan configurations, on standard CT scanners without involving additional hardware, and to investigate the potential of the short- and half-scan configurations in reducing imaging dose and scan time in a single-kVp-switch full-scan configuration in which two full rotations are made for collection of dual-energy data. We use the one-step method to reconstruct images directly from dual-energy data through solving a nonconvex optimization program that specifies the images to be reconstructed in dual-energy CT. Dual-energy full-scan data are generated from numerical phantoms and collected from physical phantoms with the standard single-kVp-switch full-scan configuration, whereas dual-energy short- and half-scan data are extracted from the corresponding full-scan data. Besides visual inspection and profile-plot comparison, the reconstructed images are analyzed also in quantitative studies based upon tasks of linear-attenuation-coefficient and material-concentration estimation and of material differentiation. Following the performance of a computer-simulation study to verify that the one-step method can reconstruct numerically accurately basis and monochromatic images of numerical phantoms, we reconstruct basis and monochromatic images by using the one-step method from real data of physical phantoms collected with the full-, short-, and half-scan configurations. Subjective inspection based upon visualization and profile-plot comparison reveals that monochromatic images, which are used often in practical applications, reconstructed from the full-, short-, and half-scan data are largely visually comparable except for some differences in texture details. Moreover, quantitative studies based upon tasks of linear-attenuation-coefficient and material-concentration estimation and of material differentiation indicate that the short- and half-scan configurations yield results in close agreement with the ground-truth information and that of the full-scan configuration. The one-step method considered can compensate effectively for the nonlinear spectral response in full- and partial-angular-scan dual-energy CT. It can be exploited for enabling partial-angular-scan configurations on standard CT scanner without involving additional hardware. Visual inspection and quantitative studies reveal that, with the one-step method, partial-angular-scan configurations considered can perform at a level comparable to that of the full-scan configuration, thus suggesting the potential of the two partial-angular-scan configurations in reducing imaging dose and scan time in the standard single-kVp-switch full-scan CT in which two full rotations are performed. The work also yields insights into the investigation and design of other nonstandard scan configurations of potential practical significance in dual-energy CT. © 2018 American Association of Physicists in Medicine.
Incidental findings in children with blunt head trauma evaluated with cranial CT scans.
Rogers, Alexander J; Maher, Cormac O; Schunk, Jeff E; Quayle, Kimberly; Jacobs, Elizabeth; Lichenstein, Richard; Powell, Elizabeth; Miskin, Michelle; Dayan, Peter; Holmes, James F; Kuppermann, Nathan
2013-08-01
Cranial computed tomography (CT) scans are frequently obtained in the evaluation of blunt head trauma in children. These scans may detect unexpected incidental findings. The objectives of this study were to determine the prevalence and significance of incidental findings on cranial CT scans in children evaluated for blunt head trauma. This was a secondary analysis of a multicenter study of pediatric blunt head trauma. Patients <18 years of age with blunt head trauma were eligible, with those undergoing cranial CT scan included in this substudy. Patients with coagulopathies, ventricular shunts, known previous brain surgery or abnormalities were excluded. We abstracted radiology reports for nontraumatic findings. We reviewed and categorized findings by their clinical urgency. Of the 43,904 head-injured children enrolled in the parent study, 15,831 underwent CT scans, and these latter patients serve as the study cohort. On 670 of these scans, nontraumatic findings were identified, with 16 excluded due to previously known abnormalities or surgeries. The remaining 654 represent a 4% prevalence of incidental findings. Of these, 195 (30%), representing 1% of the overall sample, warranted immediate intervention or outpatient follow-up. A small but important number of children evaluated with CT scans after blunt head trauma had incidental findings. Physicians who order cranial CTs must be prepared to interpret incidental findings, communicate with families, and ensure appropriate follow-up. There are ethical implications and potential health impacts of informing patients about incidental findings.
Jeon, Sun Kyung; Choi, Young Hun; Cheon, Jung-Eun; Kim, Woo Sun; Cho, Yeon Jin; Ha, Ji Young; Lee, Seung Hyun; Hyun, Hyejin; Kim, In-One
2018-04-01
The 320-row multidetector computed tomography (CT) scanner has multiple scan modes, including volumetric modes. To compare the image quality and radiation dose of 320-row CT in three acquisition modes - helical, one-shot volume, and wide-volume scan - at pediatric brain imaging. Fifty-seven children underwent unenhanced brain CT using one of three scan modes (helical scan, n=21; one-shot volume scan, n=17; wide-volume scan, n=19). For qualitative analysis, two reviewers evaluated overall image quality and image noise using a 5-point grading system. For quantitative analysis, signal-to-noise ratio, image noise and posterior fossa artifact index were calculated. To measure the radiation dose, adjusted CT dose index per unit volume (CTDI adj ) and dose length product (DLP) were compared. Qualitatively, the wide-volume scan showed significantly less image noise than the helical scan (P=0.009), and less streak artifact than the one-shot volume scan (P=0.001). The helical mode showed significantly lower signal-to-noise ratio, with a higher image noise level compared with the one-shot volume and wide-volume modes (all P<0.05). The CTDI adj and DLP were significantly lower in the one-shot volume and wide-volume modes compared with those in the helical scan mode (all P<0.05). For pediatric unenhanced brain CT, both the wide-volume and one-shot volume scans reduced radiation dose compared to the helical scan mode, while the wide-volume scan mode showed fewer streak artifacts in the skull vertex and posterior fossa than the one-shot volume scan.
Kim, Andrew J.; Francis, Richard; Liu, Xiaoqin; Devine, William A.; Ramirez, Ricardo; Anderton, Shane J.; Wong, Li Yin; Faruque, Fahim; Gabriel, George C.; Leatherbury, Linda; Tobita, Kimimasa; Lo, Cecilia W.
2013-01-01
Background Mice are well suited for modeling human congenital heart defects (CHD), given their four-chamber cardiac anatomy. However, mice with CHD invariably die prenatally/neonatally, causing CHD phenotypes to be missed. Therefore, we investigated the efficacy of noninvasive micro-computed tomography (micro-CT) to screen for CHD in stillborn/fetal mice. These studies were carried out using chemically mutagenized mice expected to be enriched for birth defects including CHD. Methods and Results Stillborn/fetal mice obtained from the breeding of N-ethyl-N-nitrosourea (ENU) mutagenized mice were formalin-fixed and stained with iodine, then micro-CT scanned. Those diagnosed with CHD and some CHD-negative pups were necropsied. A subset of these were further analyzed by histopathology to confirm the CHD/no-CHD diagnosis. Micro-CT scanning of 2105 fetal/newborn mice revealed an abundance of ventricular septal defects (VSD) (n=307). Overall, we observed an accuracy of 89.8% for VSD diagnosis. Outflow tract anomalies identified by micro-CT included double outlet right ventricle (n=36), transposition of the great arteries (n=14), and persistent truncus arteriosus (n=3). These were diagnosed with a 97.4% accuracy. Aortic arch anomalies also were readily detected with an overall 99.6% accuracy. This included right aortic arch (n=28) and coarctation/interrupted aortic arch (n=12). Also detected by micro-CT were atrioventricular septal defects (n=22), tricuspid hypoplasia/atresia (n=13), and coronary artery fistulas (n=16). They yielded accuracies of 98.9%, 100%, and 97.8% respectively. Conclusions Contrast enhanced micro-CT imaging in neonatal/fetal mice can reliably detect a wide spectrum of CHD. We conclude micro-CT imaging can be used for routine rapid assessments of structural heart defects in fetal/newborn mice. PMID:23759365
Murphy, Robert; Doerger, Kirk M; Nathan, Mark A; Lowe, Val J
2009-01-01
Physiologic uptake of 2-[(18)F]-fluoro-2-deoxy-D: -glucose (FDG) by bowel can confound positron emission tomography/computed tomography (PET/CT) assessment for abdominal pathology, particularly within the bowel itself. We wished to determine if oral administration of the antimotility agent, Lomotil (5 mg diphenoxylate hydrochloride/0.05 mg atropine sulfate; G.D. Searle and Company, a division of Pfizer), prior to PET/CT scanning would reduce physiologic uptake of FDG by the small bowel and colon (lower gastrointestinal [GI] tract). Patients undergoing PET/CT scans for lymphoma were enrolled in a prospective, randomized, double-blinded study and received either 10 mL water (control group) or 10 mL Lomotil (experimental group) orally 30-60 min prior to scanning. Scans were reviewed independently by two blinded experienced readers and scored for the degree of FDG activity in the lower GI tract relative to liver activity. The administration of Lomotil prior to PET/CT scanning did not reduce physiologic FDG activity in the small bowel and colon. In contrast, increased radiotracer uptake by the lower GI tract was observed in the Lomotil group compared to the control group. Pretreatment with Lomotil prior to PET/CT scanning confers no benefit toward the reduction of physiologic FDG uptake by the small bowel and colon.
Kim, K. P.; Berrington de González, A.; Pearce, M. S.; Salotti, J. A.; Parker, L.; McHugh, K.; Craft, A. W.; Lee, C.
2012-01-01
Despite great potential benefits, there are concerns about the possible harm from medical imaging including the risk of radiation-related cancer. There are particular concerns about computed tomography (CT) scans in children because both radiation dose and sensitivity to radiation for children are typically higher than for adults undergoing equivalent procedures. As direct empirical data on the cancer risks from CT scans are lacking, the authors are conducting a retrospective cohort study of over 240 000 children in the UK who underwent CT scans. The main objective of the study is to quantify the magnitude of the cancer risk in relation to the radiation dose from CT scans. In this paper, the methods used to estimate typical organ-specific doses delivered by CT scans to children are described. An organ dose database from Monte Carlo radiation transport-based computer simulations using a series of computational human phantoms from newborn to adults for both male and female was established. Organ doses vary with patient size and sex, examination types and CT technical settings. Therefore, information on patient age, sex and examination type from electronic radiology information systems and technical settings obtained from two national surveys in the UK were used to estimate radiation dose. Absorbed doses to the brain, thyroid, breast and red bone marrow were calculated for reference male and female individuals with the ages of newborns, 1, 5, 10, 15 and 20 y for a total of 17 different scan types in the pre- and post-2001 time periods. In general, estimated organ doses were slightly higher for females than males which might be attributed to the smaller body size of the females. The younger children received higher doses in pre-2001 period when adult CT settings were typically used for children. Paediatric-specific adjustments were assumed to be used more frequently after 2001, since then radiation doses to children have often been smaller than those to adults. The database here is the first detailed organ-specific paediatric CT scan database for the UK. As well as forming the basis for the UK study, the results and description of the methods will also serve as a key resource for paediatric CT scan studies currently underway in other countries. PMID:22228685
Kim, K P; Berrington de González, A; Pearce, M S; Salotti, J A; Parker, L; McHugh, K; Craft, A W; Lee, C
2012-07-01
Despite great potential benefits, there are concerns about the possible harm from medical imaging including the risk of radiation-related cancer. There are particular concerns about computed tomography (CT) scans in children because both radiation dose and sensitivity to radiation for children are typically higher than for adults undergoing equivalent procedures. As direct empirical data on the cancer risks from CT scans are lacking, the authors are conducting a retrospective cohort study of over 240,000 children in the UK who underwent CT scans. The main objective of the study is to quantify the magnitude of the cancer risk in relation to the radiation dose from CT scans. In this paper, the methods used to estimate typical organ-specific doses delivered by CT scans to children are described. An organ dose database from Monte Carlo radiation transport-based computer simulations using a series of computational human phantoms from newborn to adults for both male and female was established. Organ doses vary with patient size and sex, examination types and CT technical settings. Therefore, information on patient age, sex and examination type from electronic radiology information systems and technical settings obtained from two national surveys in the UK were used to estimate radiation dose. Absorbed doses to the brain, thyroid, breast and red bone marrow were calculated for reference male and female individuals with the ages of newborns, 1, 5, 10, 15 and 20 y for a total of 17 different scan types in the pre- and post-2001 time periods. In general, estimated organ doses were slightly higher for females than males which might be attributed to the smaller body size of the females. The younger children received higher doses in pre-2001 period when adult CT settings were typically used for children. Paediatric-specific adjustments were assumed to be used more frequently after 2001, since then radiation doses to children have often been smaller than those to adults. The database here is the first detailed organ-specific paediatric CT scan database for the UK. As well as forming the basis for the UK study, the results and description of the methods will also serve as a key resource for paediatric CT scan studies currently underway in other countries.
... Tomography) Scan - العربية (Arabic) Bilingual PDF Health Information Translations Chinese, Simplified (Mandarin dialect) (简体中文) Expand Section CT ( ... Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chinese, Traditional (Cantonese dialect) (繁體中文) Expand Section CT ( ...
Zhu, Zheng; Zhao, Xin-ming; Zhao, Yan-feng; Wang, Xiao-yi; Zhou, Chun-wu
2015-01-01
To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values. 26 patients (weight > 65kg and BMI ≥ 22) underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A). Another 21 patients (weight ≤ 65kg and BMI ≥ 22) were scanned with a conventional 120 kVp tube voltage for noise index (NI) of 11 with 450mgI/kg contrast material as control group (group B). GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD), signal-noise-ratio (SNR), contrast-noise-ratio (CNR) of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis. As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684). CT dose index (CTDI) values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000), respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B. The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.
Gross, Daniel J; Golijanin, Petar; Dumont, Guillaume D; Parada, Stephen A; Vopat, Bryan G; Reinert, Steven E; Romeo, Anthony A; Provencher, C D R Matthew T
2016-01-01
Computed tomography (CT) scans of the shoulder are often not well aligned to the axis of the scapula and glenoid. The purpose of this paper was to determine the effect of sagittal rotation of the glenoid on axial measurements of anterior-posterior (AP) glenoid width and glenoid version attained by standard CT scan. In addition, we sought to define the angle of rotation required to correct the CT scan to optimal positioning. A total of 30 CT scans of the shoulder were reformatted using OsiriX software multiplanar reconstruction. The uncorrected (UNCORR) and corrected (CORR) CT scans were compared for measurements of both (1) axial AP glenoid width and (2) glenoid version at 5 standardized axial cuts. The mean difference in glenoid version was 2.6% (2° ± 0.1°; P = .0222) and the mean difference in AP glenoid width was 5.2% (1.2 ± 0.42 mm; P = .0026) in comparing the CORR and UNCORR scans. The mean angle of correction required to align the sagittal plane was 20.1° of rotation (range, 9°-39°; standard error of mean, 1.2°). These findings demonstrate that UNCORR CT scans of the glenohumeral joint do not correct for the sagittal rotation of the glenoid, and this affects the characteristics of the axial images. Failure to align the sagittal image to the 12-o'clock to 6-o'clock axis results in measurement error in both glenoid version and AP glenoid width. Use of UNCORR CT images may have notable implications for decision-making and surgical treatment. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Phillip, Veit; Zahel, Tina; Danninger, Assiye; Erkan, Mert; Dobritz, Martin; Steiner, Jörg M; Kleeff, Jörg; Schmid, Roland M; Algül, Hana
2015-01-01
Regeneration of the pancreas has been well characterized in animal models. However, there are conflicting data on the regenerative capacity of the human pancreas. The aim of the present study was to assess the regenerative capacity of the human pancreas. In a retrospective study, data from patients undergoing left partial pancreatic resection at a single center were eligible for inclusion (n = 185). Volumetry was performed based on 5 mm CT-scans acquired through a 256-slice CT-scanner using a semi-automated software. Data from 24 patients (15 males/9 females) were included. Mean ± SD age was 68 ± 11 years (range, 40-85 years). Median time between surgery and the 1st postoperative CT was 9 days (range, 0-27 days; IQR, 7-13), 55 days (range, 21-141 days; IQR, 34-105) until the 2nd CT, and 191 days (range, 62-1902; IQR, 156-347) until the 3rd CT. The pancreatic volumes differed significantly between the first and the second postoperative CT scans (median volume 25.6 mL and 30.6 mL, respectively; p = 0.008) and had significantly increased further by the 3rd CT scan (median volume 37.9 mL; p = 0.001 for comparison with 1st CT scan and p = 0.003 for comparison with 2nd CT scan). The human pancreas shows a measurable and considerable potential of volumetric gain after partial resection. Multidetector-CT based semi-automated volume analysis is a feasible method for follow-up of the volume of the remaining pancreatic parenchyma after partial pancreatectomy. Effects on exocrine and endocrine pancreatic function have to be evaluated in a prospective manner. Copyright © 2015 IAP and EPC. Published by Elsevier B.V. All rights reserved.
Kornerup, Josefine S; Brodin, Patrik; Birk Christensen, Charlotte; Björk-Eriksson, Thomas; Kiil-Berthelsen, Anne; Borgwardt, Lise; Munck Af Rosenschöld, Per
2015-04-01
PET/CT may be more helpful than CT alone for radiation therapy planning, but the added risk due to higher doses of ionizing radiation is unknown. To estimate the risk of cancer induction and mortality attributable to the [F-18]2-fluoro-2-deoxyglucose (FDG) PET and CT scans used for radiation therapy planning in children with cancer, and compare to the risks attributable to the cancer treatment. Organ doses and effective doses were estimated for 40 children (2-18 years old) who had been scanned using PET/CT as part of radiation therapy planning. The risk of inducing secondary cancer was estimated using the models in BEIR VII. The prognosis of an induced cancer was taken into account and the reduction in life expectancy, in terms of life years lost, was estimated for the diagnostics and compared to the life years lost attributable to the therapy. Multivariate linear regression was performed to find predictors for a high contribution to life years lost from the radiation therapy planning diagnostics. The mean contribution from PET to the effective dose from one PET/CT scan was 24% (range: 7-64%). The average proportion of life years lost attributable to the nuclear medicine dose component from one PET/CT scan was 15% (range: 3-41%). The ratio of life years lost from the radiation therapy planning PET/CT scans and that of the cancer treatment was on average 0.02 (range: 0.01-0.09). Female gender was associated with increased life years lost from the scans (P < 0.001). Using FDG-PET/CT instead of CT only when defining the target volumes for radiation therapy of children with cancer does not notably increase the number of life years lost attributable to diagnostic examinations.
Variations in the intensive use of head CT for elderly patients with hemorrhagic stroke.
Bekelis, Kimon; Fisher, Elliott S; Labropoulos, Nicos; Zhou, Weiping; Skinner, Jonathan
2015-04-01
To investigate the variability in head computed tomographic (CT) scanning in patients with hemorrhagic stroke in U.S. hospitals, its association with mortality, and the number of different physicians consulted. The study was approved by the Committee for the Protection of Human Subjects at Dartmouth College. A retrospective analysis of the Medicare fee-for-service claims data was performed for elderly patients admitted for hemorrhagic stroke in 2008-2009, with 1-year follow-up through 2010. Risk-adjusted primary outcome measures were mean number of head CT scans performed and high-intensity use of head CT (six or more head CT scans performed in the year after admission). We examined the association of high-intensity use of head CT with the number of different physicians consulted and mortality. A total of 53 272 patients (mean age, 79.6 years; 31 377 women [58.9%]) with hemorrhagic stroke were identified in the study period. The mean number of head CT scans conducted in the year after admission for stroke was 3.4; 8737 patients (16.4%) underwent six or more scans. Among the hospitals with the highest case volume (more than 50 patients with hemorrhagic stroke), risk-adjusted rates ranged from 8.0% to 48.1%. The correlation coefficient between number of physicians consulted and rates of high-intensity use of head CT was 0.522 (P < .01) for all hospitals and 0.50 (P < .01) for the highest-volume hospitals. No improvement in 1-year mortality was found for patients undergoing six or more head CT scans (odds ratio, 0.84; 95% confidence interval: 0.69, 1.02). High rates of head CT use for patients with hemorrhagic stroke are frequently observed, without an association with decreased mortality. A higher number of physicians consulted was associated with high-intensity use of head CT. © RSNA, 2014 Online supplemental material is available for this article.
Use of the initial trauma CT scan to aid in diagnosis of open pelvic fractures.
Scolaro, John A; Wilson, David J; Routt, Milton Lee Chip; Firoozabadi, Reza
2015-10-01
Open pelvic disruptions represent high-energy injuries. The prompt identification and management of these injuries decreases their associated morbidity and mortality. Computed tomography (CT) scans are routinely obtained in the initial evaluation of patients with pelvic injuries. The purpose of this study is to identify the incidence and source of air densities noted on computed tomography (CT) scans of the abdominal and pelvic region in patients with pelvic fractures and evaluate the use of initial CT imaging as an adjunctive diagnostic tool to identify open injuries. A retrospective review of a prospectively collected database was performed at a single institution. Seven hundred and twenty-two consecutive patients with a pelvic disruption over a two-year period were included. Review of initial injury CT scans was performed using bone and lung viewing algorithms to identify the presence of extra-luminal air. The primary outcome was the presence, location and source of air identified on pre-operative CT scans. Secondary measurements were identification of air by plain radiograph and correlation between identified air densities on CT and clinically diagnosed open pelvic fractures. Ninety-eight patients were identified as having extra-luminal air densities on CT scans. Eighty-one patients were included in the final analysis following application of inclusion and exclusion criteria. Air was noted by the radiologist in forty-five (55.6%) instances. Six patients (7.4%) were clinically diagnosed with an open pelvic ring disruption; in two patients (2.4%) this diagnosis was delayed. In all patients, the CT was able to track air from its origin. In patients with pelvic disruptions, the injury CT should also be evaluated for the presence and source of extra-luminal air. In some patients, this finding may represent an open pelvic ring disruption. A complete physical exam and CT evaluation should be used to decrease the missed or delayed diagnosis of an open pelvic ring injury. Copyright © 2015 Elsevier Ltd. All rights reserved.
Malignant external otitis: the role of computed tomography and radionuclides in evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendelson, D.S.; Som, P.M.; Mendelson, M.H.
1983-12-01
Nine patients with malignant external otitis (MEO) were evaluated with Tc-99m bone scans, Ga-67 citrate scans, pluridirectional tomography, and computed tomographic (CT) scans in order to assess the role of each in the diagnosis and management of MEO. The Tc-99m and Ga-67 citrate scans were the most accurate studies in the initial identification of disease activity, while the return to normal or improvement of the Ga-67 citrate scan has been shown to correlate best with clinical resolution of MEO. CT demonstrated soft-tissue disease and central skull base osteomyelitis better than pluridirectional tomography. CT is excellent for localizing and following themore » progression of bone disease; however, because reossification of the skull base is a very slow process, CT cannot be used to follow accurately regression or inactivity of MEO affecting this area. CT is the best modality for following soft-tissue extension of MEO.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plets, C.; Baert, A.L.; Nijs, G.L.
1986-01-01
It is of the greatest importance to the radiologist, the neurologist and the neurosurgeon to be able to localize topographically a pathological brain process on the CT scan as precisely as possible. For that purpose, the identification of as many anatomical structures as possible on the CT scan image are necessary and indispensable. In this atlas a great number of detailed anatomical data on frontal horizontal CT scan sections, each being only 2 mm thick, are indicated, e.g. the cortical gyri, the basal ganglia, details of the white matter, extracranial muscles and blood vessels, parts of the base and themore » vault of the skull, etc. The very precise topographical description of the numerous CT scan images was realized by the author by confrontation of these images with the corresponding anatomical sections of the same brain specimen, performed by an original technique.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yin, Zhye, E-mail: yin@ge.com; De Man, Bruno; Yao, Yangyang
Purpose: Traditionally, 2D radiographic preparatory scan images (scout scans) are used to plan diagnostic CT scans. However, a 3D CT volume with a full 3D organ segmentation map could provide superior information for customized scan planning and other purposes. A practical challenge is to design the volumetric scout acquisition and processing steps to provide good image quality (at least good enough to enable 3D organ segmentation) while delivering a radiation dose similar to that of the conventional 2D scout. Methods: The authors explored various acquisition methods, scan parameters, postprocessing methods, and reconstruction methods through simulation and cadaver data studies tomore » achieve an ultralow dose 3D scout while simultaneously reducing the noise and maintaining the edge strength around the target organ. Results: In a simulation study, the 3D scout with the proposed acquisition, preprocessing, and reconstruction strategy provided a similar level of organ segmentation capability as a traditional 240 mAs diagnostic scan, based on noise and normalized edge strength metrics. At the same time, the proposed approach delivers only 1.25% of the dose of a traditional scan. In a cadaver study, the authors’ pictorial-structures based organ localization algorithm successfully located the major abdominal-thoracic organs from the ultralow dose 3D scout obtained with the proposed strategy. Conclusions: The authors demonstrated that images with a similar degree of segmentation capability (interpretability) as conventional dose CT scans can be achieved with an ultralow dose 3D scout acquisition and suitable postprocessing. Furthermore, the authors applied these techniques to real cadaver CT scans with a CTDI dose level of less than 0.1 mGy and successfully generated a 3D organ localization map.« less
NASA Astrophysics Data System (ADS)
Ramakrishnan, Sowmya; Alvino, Christopher; Grady, Leo; Kiraly, Atilla
2011-03-01
We present a complete automatic system to extract 3D centerlines of ribs from thoracic CT scans. Our rib centerline system determines the positional information for the rib cage consisting of extracted rib centerlines, spinal canal centerline, pairing and labeling of ribs. We show an application of this output to produce an enhanced visualization of the rib cage by the method of Kiraly et al., in which the ribs are digitally unfolded along their centerlines. The centerline extraction consists of three stages: (a) pre-trace processing for rib localization, (b) rib centerline tracing, and (c) post-trace processing to merge the rib traces. Then we classify ribs from non-ribs and determine anatomical rib labeling. Our novel centerline tracing technique uses the Random Walker algorithm to segment the structural boundary of the rib in successive 2D cross sections orthogonal to the longitudinal direction of the ribs. Then the rib centerline is progressively traced along the rib using a 3D Kalman filter. The rib centerline extraction framework was evaluated on 149 CT datasets with varying slice spacing, dose, and under a variety of reconstruction kernels. The results of the evaluation are presented. The extraction takes approximately 20 seconds on a modern radiology workstation and performs robustly even in the presence of partial volume effects or rib pathologies such as bone metastases or fractures, making the system suitable for assisting clinicians in expediting routine rib reading for oncology and trauma applications.
Direct microCT imaging of non-mineralized connective tissues at high resolution.
Naveh, Gili R S; Brumfeld, Vlad; Dean, Mason; Shahar, Ron; Weiner, Steve
2014-01-01
The 3D imaging of soft tissues in their native state is challenging, especially when high resolution is required. An X-ray-based microCT is, to date, the best choice for high resolution 3D imaging of soft tissues. However, since X-ray attenuation of soft tissues is very low, contrasting enhancement using different staining materials is needed. The staining procedure, which also usually involves tissue fixation, causes unwanted and to some extent unknown tissue alterations. Here, we demonstrate that a method that enables 3D imaging of soft tissues without fixing and staining using an X-ray-based bench-top microCT can be applied to a variety of different tissues. With the sample mounted in a custom-made loading device inside a humidity chamber, we obtained soft tissue contrast and generated 3D images of fresh, soft tissues with a resolution of 1 micron voxel size. We identified three critical conditions which make it possible to image soft tissues: humidified environment, mechanical stabilization of the sample and phase enhancement. We demonstrate the capability of the technique using different specimens: an intervertebral disc, the non-mineralized growth plate, stingray tessellated radials (calcified cartilage) and the collagenous network of the periodontal ligament. Since the scanned specimen is fresh an interesting advantage of this technique is the ability to scan a specimen under load and track the changes of the different structures. This method offers a unique opportunity for obtaining valuable insights into 3D structure-function relationships of soft tissues.
Forsythe, Anna V; Brady, Zoe; Butler, Martin W; Goergen, Stacy K; Byrnes, Graham B; Giles, Graham G; Wallace, Anthony B; Anderson, Philip R; Guiver, Tenniel A; McGale, Paul; Cain, Timothy M; Dowty, James G; Bickerstaffe, Adrian C; Darby, Sarah C
2013-01-01
Objective To assess the cancer risk in children and adolescents following exposure to low dose ionising radiation from diagnostic computed tomography (CT) scans. Design Population based, cohort, data linkage study in Australia. Cohort members 10.9 million people identified from Australian Medicare records, aged 0-19 years on 1 January 1985 or born between 1 January 1985 and 31 December 2005; all exposures to CT scans funded by Medicare during 1985-2005 were identified for this cohort. Cancers diagnosed in cohort members up to 31 December 2007 were obtained through linkage to national cancer records. Main outcome Cancer incidence rates in individuals exposed to a CT scan more than one year before any cancer diagnosis, compared with cancer incidence rates in unexposed individuals. Results 60 674 cancers were recorded, including 3150 in 680 211 people exposed to a CT scan at least one year before any cancer diagnosis. The mean duration of follow-up after exposure was 9.5 years. Overall cancer incidence was 24% greater for exposed than for unexposed people, after accounting for age, sex, and year of birth (incidence rate ratio (IRR) 1.24 (95% confidence interval 1.20 to 1.29); P<0.001). We saw a dose-response relation, and the IRR increased by 0.16 (0.13 to 0.19) for each additional CT scan. The IRR was greater after exposure at younger ages (P<0.001 for trend). At 1-4, 5-9, 10-14, and 15 or more years since first exposure, IRRs were 1.35 (1.25 to 1.45), 1.25 (1.17 to 1.34), 1.14 (1.06 to 1.22), and 1.24 (1.14 to 1.34), respectively. The IRR increased significantly for many types of solid cancer (digestive organs, melanoma, soft tissue, female genital, urinary tract, brain, and thyroid); leukaemia, myelodysplasia, and some other lymphoid cancers. There was an excess of 608 cancers in people exposed to CT scans (147 brain, 356 other solid, 48 leukaemia or myelodysplasia, and 57 other lymphoid). The absolute excess incidence rate for all cancers combined was 9.38 per 100 000 person years at risk, as of 31 December 2007. The average effective radiation dose per scan was estimated as 4.5 mSv. Conclusions The increased incidence of cancer after CT scan exposure in this cohort was mostly due to irradiation. Because the cancer excess was still continuing at the end of follow-up, the eventual lifetime risk from CT scans cannot yet be determined. Radiation doses from contemporary CT scans are likely to be lower than those in 1985-2005, but some increase in cancer risk is still likely from current scans. Future CT scans should be limited to situations where there is a definite clinical indication, with every scan optimised to provide a diagnostic CT image at the lowest possible radiation dose. PMID:23694687
Bush, Lisa; Brookshire, Robert; Roche, Breanna; Johnson, Amelia; Cole, Frederic; Karmy-Jones, Riyad; Long, William; Martin, Matthew J
2016-09-01
Current trauma guidelines dictate that the cervical spine should not be cleared in intoxicated patients, resulting in prolonged immobilization or additional imaging. Modern computed tomography (CT) technology may obviate this and allow for immediate clearance. To analyze cervical spine clearance practices and the utility of CT scans of the cervical spine in intoxicated patients with blunt trauma. We performed a prospective observational study of 1668 patients with blunt trauma aged 18 years and older who underwent cervical spine CT scans from March 2014 to March 2015 at an American College of Surgeons-verified Level I trauma center. Intoxication was determined by serum alcohol levels and urine drug screens. Physical examination and CT scan findings were evaluated for cervical spine injuries (CSI) and the incidence of missed injuries. Clinically relevant CSIs requiring cervical stabilization. The hypotheses formed prior to data collection were that cervical CT scans are sensitive and specific enough to diagnose CSIs that require stabilization and that normal CT scans are sufficient to clear CSIs in intoxicated patients. Of 1668 patients, 1103 (66.1%) were male, with a mean (SD) age of 49 (20) years and a mean (SD) Injury Severity Score of 10 (9). Vehicular (734 [44.0%]) and falls (579 [34.7%]) were the most common mechanisms for hospitalization. Intoxication was identified in 632 of 1429 of patients tested (44.2%; 425 [29.7%] by serum alcohol levels and 350 [24.5%] by urine drug screens). Half (316 [50.0%]) were admitted with cervical spine immobilization, and 38 (12%) of these were solely owing to the presence of intoxication. There were 65 abnormal CT scans (10.3%) in the intoxicated group. Among 567 normal CT scans, 4 (0.7%) had central cord syndrome found on initial physical examination, and 1 (0.2%) had a symptomatic unstable ligament injury that was misread as normal on CT scan but was abnormal on magnetic resonance imaging. The 316 patients kept in a cervical collar for intoxication had no missed CSIs but were kept immobilized for a mean (SD) of 12 (19) hours. Computed tomographic scans had an overall negative predictive value of 99.2% for patients with CSIs and a negative predictive value of 99.8% for ruling out CSIs that required immobilization or stabilization. In this study, alcohol or drug intoxication was common and resulted in significant delays to cervical spine clearance. Computed tomographic scans were highly reliable for identifying all clinically significant CSIs. Spine clearance based on a normal CT scan among intoxicated patients with no gross motor deficits appears to be safe and avoids prolonged and unnecessary immobilization.
Hepatic perivascular epithelioid cell tumor: five case reports and literature review.
Liu, Zhen; Qi, Yafei; Wang, Chuanzhuo; Zhang, Xiaobo; Wang, Baosheng
2015-01-01
Perivascular epithelioid cell tumor (PEComa) is a rare tumor. Here, we present data regarding clinical presentations, diagnoses, management, and prognosis of five cases of hepatic PEComa between January 2002 and December 2008. Ultrasonography showed hyperechoic masses in all patients. Precontrast computed tomography (CT) showed that all lesions scanned were heterogeneous in density and were heterogeneously enhanced in arterial phase images. In two cases, magnetic resonance imaging showed hypointensity on T1-weighted images and hyperintensity on T2-weighted images. In enhanced scanning, lesions showed asymmetrical enhancement during arterial phase imaging. All tumors were composed of varying proportions of smooth muscle, adipose tissue, and thick-walled blood vessels, and showed positive immunohistochemical staining for Human Melanoma Black-45. All patients underwent hepatectomy, and there was no evidence of recurrence or metastasis during the follow-up period. Copyright © 2012. Published by Elsevier Taiwan.
Relationship between Hounsfield unit in CT scan and gray scale in CBCT
NASA Astrophysics Data System (ADS)
Kamaruddin, Noorshaida; Rajion, Zainul Ahmad; Yusof, Asilah; Aziz, Mohd Ezane
2016-12-01
Cone-beam computed tomography (CBCT) is an imaging system which has advantages over computed tomography (CT). Recently, CBCT has become widely used for oral and maxillofacial imaging. In CT scan, Hounsfield Unit (HU) is proportional to the degree of x-ray attenuation by the tissue. In CBCT, the degree of x-ray attenuation is shown by gray scale (voxel value). The aim of the present (in vitro) study was to investigate the relationship between gray scale in CBCT and HU in CT scan. In this descriptive study, the anthropomorphic head phantom was scanned with CBCT and CT scanner. Gray scales and HUs were detected on images at the crown of the teeth, trabecular and cortical bone of mandible. The images were analyzed to obtain the gray scale value and HU value. The obtained value then used to investigate the relationship between CBCT gray scales and HUs. For the statistical analysis, t-test, Pearson's correlation and regression analysis were used. The differences between the gray scale of CBCT and HU of CT were statistically not significant, whereas the Pearson's correlation coefficients demonstrated a statistically significant correlation between gray scale of CBCT and HU of CT values. Considering the fact that gray scale in CBCT is important in pre assessment evaluation of bone density before implant treatments, it is recommended because of the lower dose and cost compared to CT scan.
Dual scan CT image recovery from truncated projections
NASA Astrophysics Data System (ADS)
Sarkar, Shubhabrata; Wahi, Pankaj; Munshi, Prabhat
2017-12-01
There are computerized tomography (CT) scanners available commercially for imaging small objects and they are often categorized as mini-CT X-ray machines. One major limitation of these machines is their inability to scan large objects with good image quality because of the truncation of projection data. An algorithm is proposed in this work which enables such machines to scan large objects while maintaining the quality of the recovered image.
Quantification of pleural effusion on CT by simple measurement.
Hazlinger, Martin; Ctvrtlik, Filip; Langova, Katerina; Herman, Miroslav
2014-01-01
To find the simplest method for quantifying pleural effusion volume from CT scans. Seventy pleural effusions found on chest CT examination in 50 consecutive adult patients with the presence of free pleural effusion were included. The volume of pleural effusion was calculated from a three-dimensional reconstruction of CT scans. Planar measurements were made on CT scans and their two-dimensional reconstructions in the sagittal plane and at three levels on transversal scans. Individual planar measurements were statistically compared with the detected volume of pleural effusion. Regression equations, averaged absolute difference between observed and predicted values and determination coefficients were found for all measurements and their combinations. A tabular expression of the best single planar measurement was created. The most accurate correlation between the volume and a single planar measurement was found in the dimension measured perpendicular to the parietal pleura on transversal scan with the greatest depth of effusion. Conversion of this measurement to the appropriate volume is possible by regression equation: Volume = 0.365 × b(3) - 4.529 × b(2) + 159.723 × b - 88.377. We devised a simple method of conversion of a single planar measurement on CT scan to the volume of pleural effusion. The tabular expression of our equation can be easily and effectively used in routine practice.
Pelvic artery calcification detection on CT scans using convolutional neural networks
NASA Astrophysics Data System (ADS)
Liu, Jiamin; Lu, Le; Yao, Jianhua; Bagheri, Mohammadhadi; Summers, Ronald M.
2017-03-01
Artery calcification is observed commonly in elderly patients, especially in patients with chronic kidney disease, and may affect coronary, carotid and peripheral arteries. Vascular calcification has been associated with many clinical outcomes. Manual identification of calcification in CT scans requires substantial expert interaction, which makes it time-consuming and infeasible for large-scale studies. Many works have been proposed for coronary artery calcification detection in cardiac CT scans. In these works, coronary artery extraction is commonly required for calcification detection. However, there are few works about abdominal or pelvic artery calcification detection. In this work, we present a method for automatic pelvic artery calcification detection on CT scan. This method uses the recent advanced faster region-based convolutional neural network (R-CNN) to directly identify artery calcification without a need for artery extraction since pelvic artery extraction itself is challenging. Our method first generates category-independent region proposals for each slice of the input CT scan using region proposal networks (RPN). Then, each region proposal is jointly classified and refined by softmax classifier and bounding box regressor. We applied the detection method to 500 images from 20 CT scans of patients for evaluation. The detection system achieved a 77.4% average precision and a 85% sensitivity at 1 false positive per image.
What is the best imaging strategy for acute stroke?
Wardlaw, J M; Keir, S L; Seymour, J; Lewis, S; Sandercock, P A G; Dennis, M S; Cairns, J
2004-01-01
To determine the cost-effectiveness of computed tomographic (CT) scanning after acute stroke. To assess the contribution of brain imaging to the diagnosis and management of stroke, and to estimate the costs, benefits and risks of different imaging strategies in order to provide data to inform national and local policy on the use of brain imaging in stroke. A decision-analysis model was developed to represent the pathway of care in acute stroke using 'scan all patients within 48 hours' as the comparator against which to cost 12 alternative scan strategies. Hospitals in Scotland. Subjects were patients admitted to hospital with a first stroke and those managed as outpatients. The effect on functional outcome after ischaemic or haemorrhagic stroke, tumours or infections, of correctly administered antithrombotic or other treatment; of time to scan and stroke severity on diagnosis by CT or MRI; on management, including length of stay, functional outcome, and quality-adjusted life years (QALYs), of the diagnostic information provided by CT scanning; the cost-effectiveness (cost versus QALYs) of different strategies for use of CT after acute stroke. Death and functional outcome at long-term follow-up; accuracy of CT and MRI; cost of CT scanning by time of day and week; effect of CT diagnosis on change in health outcome, length of stay in hospital and QALYs; cost-effectiveness of various scanning strategies. CT is very sensitive and specific for haemorrhage within the first 8 days of stroke only. Suboptimal scanning used in epidemiology studies suggests that the frequency of primary intracerebral haemorrhage (PICH) has been underestimated. Aspirin increases the risk of PICH. There were no reliable data on functional outcome or on the effect of antithrombotic treatment given long term after PICH. In 60% of patients with recurrent stroke after PICH, the cause is another PICH and mortality is high among PICH patients. A specific MR sequence (gradient echo) is required to identify prior PICH reliably. CT scanners were distributed unevenly in Scotland, 65% provided CT scanning within 48 hours of stroke, and 100% within 7 days for hospital-admitted patients, but access out of hours was very variable, and for outpatients was poor. The average cost of a CT brain scan for stroke was pounds 30.23 to pounds 89.56 in normal working hours and pounds 55.05 to pounds 173.46 out of hours. Average length of stay was greatest for severe strokes and those who survived in a dependent state. For a cohort of 1000 patients aged 70-74 years, the policy 'scan all strokes within 48 hours', cost pounds 10,279,728 and achieved 1982.3 QALYS. The most cost-effective strategy was 'scan all immediately' (pounds 9,993,676 and 1982.4 QALYS). The least cost-effective was to 'scan patients on anticoagulants, in a life-threatening condition immediately and the rest within 14 days'. In general, strategies in which most patients were scanned immediately cost least and achieved the most QALYs, as the cost of providing CT (even out of hours) was less than the cost of inpatient care. Increasing independent survival by even a small proportion through early use of aspirin in the majority with ischaemic stroke, avoiding aspirin in those with haemorrhagic stroke, and appropriate early management of those who have not had a stroke, reduced costs and increased QALYs.
Berrington de Gonzalez, Amy; Journy, Neige; Lee, Choonsik; Morton, Lindsay M; Harbron, Richard W; Stewart, Douglas R; Parker, Louise; Craft, Alan W; McHugh, Kieran; Little, Mark P; Pearce, Mark S
2017-05-01
Background: We examined the relationship between estimated radiation dose from CT scans and subsequent Hodgkin lymphoma in the UK pediatric CT scans cohort. Methods: A retrospective, record linkage cohort included patients ages 0 to 21 years who underwent CT scans between 1980 and 2002 and were followed up for cancer or death until 2008. Poisson regression analysis was used to evaluate the relationship between estimated radiation dose (lagged by 2 years) and incident Hodgkin lymphoma diagnosed at least 2 years after the first CT scan. Results: There were 65 incident cases of Hodgkin lymphoma in the cohort of 178,601 patients. Neither estimated red bone marrow dose nor mean lymphocyte dose from CT scans was clearly associated with an increased risk of Hodgkin lymphoma (RR for 20+ mGy vs. <5 mGy = 0.92 (0.38-2.22) P trend > 0.5 and 1.44 (0.60-3.48) P trend > 0.5), respectively. Conclusions: Radiation exposure from pediatric CT scans 2 or more years before diagnosis was not associated with Hodgkin lymphoma in this large UK cohort. Impact: These findings are consistent with the majority of previous studies, which do not support a link between ionizing radiation and Hodgkin lymphoma. The results contrast our previous positive findings in this cohort for brain tumors and leukemia, both of which are known to be strongly linked to radiation exposure during childhood. Cancer Epidemiol Biomarkers Prev; 26(5); 804-6. ©2017 AACR . ©2017 American Association for Cancer Research.
Blumfield, Einat; Zember, Jonathan; Guelfguat, Mark; Blumfield, Amit; Goldman, Harold
2015-12-01
We would like to share our experience of reducing pediatric radiation exposure. Much of the recent literature regarding successes of reducing radiation exposure has come from dedicated children's hospitals. Nonetheless, over the past two decades, there has been a considerable increase in CT imaging of children in the USA, predominantly in non-pediatric-focused facilities where the majority of children are treated. In our institution, two general hospitals with limited pediatric services, a dedicated initiative intended to reduce children's exposure to CT radiation was started by pediatric radiologists in 2005. The initiative addressed multiple issues including eliminating multiphase studies, decreasing inappropriate scans, educating referring providers, training residents and technologists, replacing CT with ultrasound or MRI, and ensuring availability of pediatric radiologists for consultation. During the study period, the total number of CT scans decreased by 24 %. When accounting for the number of scans per visit to the emergency department (ED), the numbers of abdominal and head CT scans decreased by 37.2 and 35.2 %, respectively. For abdominal scans, the average number of phases per scan decreased from 1.70 to 1.04. Upon surveying the pediatric ED staff, it was revealed that the most influential factors on ordering of scans were daily communication with pediatric radiologists, followed by journal articles and lectures by pediatric radiologists. We concluded that a non-pediatric-focused facility can achieve dramatic reduction in CT radiation exposure to children; however, this is most effectively achieved through a dedicated, multidisciplinary process led by pediatric radiologists.
Image quality of conventional images of dual-layer SPECTRAL CT: A phantom study.
van Ommen, Fasco; Bennink, Edwin; Vlassenbroek, Alain; Dankbaar, Jan Willem; Schilham, Arnold M R; Viergever, Max A; de Jong, Hugo W A M
2018-05-10
Spectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips Healthcare) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips Healthcare), by means of phantom experiments. For both CT scanners, conventional CT images were acquired using four adult scanning protocols: (a) body helical, (b) body axial, (c) head helical, and (d) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. The resolution levels at 50%, 10%, and 5% MTF of the iCT and IQon showed small, but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with differences up to 0.51. Spatial resolution did not change with phantom size, but noise levels increased significantly. For head scans, IQon had a noise level that was significantly lower than the iCT, on the other hand IQon showed noise levels significantly higher than the iCT for body scans. Still, these differences were well within the specified range of performance of iCT scanners. At equivalent dose levels, this study showed similar quality of conventional images acquired on iCT and IQon for medium-sized phantoms and slightly degraded image quality for (very) large phantoms at lower tube voltages on the IQon. Accordingly, it may be concluded that the introduction of a dual-layer detector neither compromises image quality of conventional images nor increases radiation dose for normal-sized patients, and slightly degrades dose efficiency for large patients at 120 kVp and lower tube voltages. © 2018 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis
Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M
2017-01-01
The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a “routine” PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures. PMID:29348980
The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis.
Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M
2017-01-01
The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a "routine" PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures.
Estimation of skull table thickness with clinical CT and validation with microCT.
Lillie, Elizabeth M; Urban, Jillian E; Weaver, Ashley A; Powers, Alexander K; Stitzel, Joel D
2015-01-01
Brain injuries resulting from motor vehicle crashes (MVC) are extremely common yet the details of the mechanism of injury remain to be well characterized. Skull deformation is believed to be a contributing factor to some types of traumatic brain injury (TBI). Understanding biomechanical contributors to skull deformation would provide further insight into the mechanism of head injury resulting from blunt trauma. In particular, skull thickness is thought be a very important factor governing deformation of the skull and its propensity for fracture. Current computed tomography (CT) technology is limited in its ability to accurately measure cortical thickness using standard techniques. A method to evaluate cortical thickness using cortical density measured from CT data has been developed previously. This effort validates this technique for measurement of skull table thickness in clinical head CT scans using two postmortem human specimens. Bone samples were harvested from the skulls of two cadavers and scanned with microCT to evaluate the accuracy of the estimated cortical thickness measured from clinical CT. Clinical scans were collected at 0.488 and 0.625 mm in plane resolution with 0.625 mm thickness. The overall cortical thickness error was determined to be 0.078 ± 0.58 mm for cortical samples thinner than 4 mm. It was determined that 91.3% of these differences fell within the scanner resolution. Color maps of clinical CT thickness estimations are comparable to color maps of microCT thickness measurements, indicating good quantitative agreement. These data confirm that the cortical density algorithm successfully estimates skull table thickness from clinical CT scans. The application of this technique to clinical CT scans enables evaluation of cortical thickness in population-based studies. © 2014 Anatomical Society.
Hubbard, Patricia; Callahan, Jason; Cramb, Jim; Budd, Ray; Kron, Tomas
2015-06-01
To review the dose delivered to patients in time-resolved computed tomography (4D CT) used for radiotherapy treatment planning. 4D CT is used at Peter MacCallum Cancer Centre since July 2007 for radiotherapy treatment planning using a Philips Brilliance Wide Bore CT scanner (16 slice, helical 4D CT acquisition). All scans are performed at 140 kVp and reconstructed in 10 datasets for different phases of the breathing cycle. Dose records were analysed retrospectively for 387 patients who underwent 4D CT procedures between 2007 and 2013. A total of 444 4D CT scans were acquired with the majority of them (342) being for lung cancer radiotherapy. Volume CT dose index (CTDIvol) as recorded over this period was fairly constant at approximately 20 mGy for adults. The CTDI for 4D CT for lung cancers of 19.6 ± 9.3 mGy (n = 168, mean ± 1SD) was found to be 63% higher than CTDIs for conventional CT scans for lung patients that were acquired in the same period (CTDIvol 12 ± 4 mGy, sample of n = 25). CTDI and dose length product (DLP) increased with increasing field of view; however, no significant difference between DLPs for different indications (breast, kidney, liver and lung) could be found. Breathing parameters such as breathing rate or pattern did not affect dose. 4D CT scans can be acquired for radiotherapy treatment planning with a dose less than twice the one required for conventional CT scanning. © 2015 The Royal Australian and New Zealand College of Radiologists.
The Value of 18F-FDG PET/CT in Diagnosis and During Follow-up in 273 Patients with Chronic Q Fever.
Kouijzer, Ilse J E; Kampschreur, Linda M; Wever, Peter C; Hoekstra, Corneline; van Kasteren, Marjo E E; de Jager-Leclercq, Monique G L; Nabuurs-Franssen, Marrigje H; Wegdam-Blans, Marjolijn C A; Ammerlaan, Heidi S M; Buijs, Jacqueline; Geus-Oei, Lioe-Fee de; Oyen, Wim J G; Bleeker-Rovers, Chantal P
2018-01-01
In 1%-5% of all acute Q fever infections, chronic Q fever develops, mostly manifesting as endocarditis, infected aneurysms, or infected vascular prostheses. In this study, we investigated the diagnostic value of 18 F-FDG PET/CT in chronic Q fever at diagnosis and during follow-up. Methods: All adult Dutch patients suspected of chronic Q fever who were diagnosed since 2007 were retrospectively included until March 2015, when at least one 18 F-FDG PET/CT scan was obtained. Clinical data and results from 18 F-FDG PET/CT at diagnosis and during follow-up were collected. 18 F-FDG PET/CT scans were prospectively reevaluated by 3 nuclear medicine physicians using a structured scoring system. Results: In total, 273 patients with possible, probable, or proven chronic Q fever were included. Of all 18 F-FDG PET/CT scans performed at diagnosis, 13.5% led to a change in diagnosis. Q fever-related mortality rate in patients with and without vascular infection based on 18 F-FDG PET/CT was 23.8% and 2.1%, respectively ( P = 0.001). When 18 F-FDG PET/CT was added as a major criterion to the modified Duke criteria, 17 patients (1.9-fold increase) had definite endocarditis. At diagnosis, 19.6% of 18 F-FDG PET/CT scans led to treatment modification. During follow-up, 57.3% of 18 F-FDG PET/CT scans resulted in treatment modification. Conclusion: 18 F-FDG PET/CT is a valuable technique in diagnosis of chronic Q fever and during follow-up, often leading to a change in diagnosis or treatment modification and providing important prognostic information on patient survival. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.
New scoring system for intra-abdominal injury diagnosis after blunt trauma.
Shojaee, Majid; Faridaalaee, Gholamreza; Yousefifard, Mahmoud; Yaseri, Mehdi; Arhami Dolatabadi, Ali; Sabzghabaei, Anita; Malekirastekenari, Ali
2014-01-01
An accurate scoring system for intra-abdominal injury (IAI) based on clinical manifestation and examination may decrease unnecessary CT scans, save time, and reduce healthcare cost. This study is designed to provide a new scoring system for a better diagnosis of IAI after blunt trauma. This prospective observational study was performed from April 2011 to October 2012 on patients aged above 18 years and suspected with blunt abdominal trauma (BAT) admitted to the emergency department (ED) of Imam Hussein Hospital and Shohadaye Hafte Tir Hospital. All patients were assessed and treated based on Advanced Trauma Life Support and ED protocol. Diagnosis was done according to CT scan findings, which was considered as the gold standard. Data were gathered based on patient's history, physical exam, ultrasound and CT scan findings by a general practitioner who was not blind to this study. Chi-square test and logistic regression were done. Factors with significant relationship with CT scan were imported in multivariate regression models, where a coefficient (β) was given based on the contribution of each of them. Scoring system was developed based on the obtained total β of each factor. Altogether 261 patients (80.1% male) were enrolled (48 cases of IAI). A 24-point blunt abdominal trauma scoring system (BATSS) was developed. Patients were divided into three groups including low (score<8), moderate (8≤score<12) and high risk (score≥12). In high risk group immediate laparotomy should be done, moderate group needs further assessments, and low risk group should be kept under observation. Low risk patients did not show positive CT-scans (specificity 100%). Conversely, all high risk patients had positive CT-scan findings (sensitivity 100%). The receiver operating characteristic curve indicated a close relationship between the results of CT scan and BATSS (sensitivity=99.3%). The present scoring system furnishes a high precision and reproducible diagnostic tool for BAT detection and has the potential to reduce unnecessary CT scan and cut unnecessary costs.
Hu, Zhi-Jun; He, Jian; Zhao, Feng-Dong; Fang, Xiang-Qian; Zhou, Li-Na; Fan, Shun-Wu
2011-06-01
A reliability study was conducted. To estimate the intra- and intermeasurement errors in the measurements of functional cross-sectional area (FCSA), density, and T2 signal intensity of paraspinal muscles using computed tomography (CT) scan and magnetic resonance imaging (MRI). CT scan and MRI had been used widely to measure the cross-sectional area and degeneration of the back muscles in spine and muscle research. But there is still no systemic study to analyze the reliability of these measurements. This study measured the FCSA and fatty infiltration (density on CT scan and T2 signal intensity on MRI) of the paraspinal muscles at L3-L4, L4-L5, and L5-S1 in 29 patients with chronic low back pain. Two experienced musculoskeletal radiologists and one superior spine surgeon traced the region of interest twice within 3 weeks for measurement of the intra- and interobserver reliability. The intraclass correlation coefficients (ICCs) of the intra-reliability ranged from fair to excellent for FCSA, and good to excellent for fatty infiltration. The ICCs of the inter-reliability ranged from fair to excellent for FCSA, and good to excellent for fatty infiltration. There were no significant differences between CT scan and MRI in reliability results, except in the relative standard error of fatty infiltration measurement. The ICCs of the FCSA measurement between CT scan and MRI ranged from poor to good. The reliabilities of the CT scan and MRI for measuring the FCSA and fatty infiltration of the atrophied lumbar paraspinal muscles were acceptable. It was reliable for using uniform one image method for a single paraspinal muscle evaluation study. And the authors preferred to advise the MRI other than CT scan for paraspinal muscles measurements of FCSA and fatty infiltration.
Eye lens radiation exposure and repeated head CT scans: A problem to keep in mind.
Michel, Morgane; Jacob, Sophie; Roger, Gilles; Pelosse, Béatrice; Laurier, Dominique; Le Pointe, Hubert Ducou; Bernier, Marie-Odile
2012-08-01
The deterministic character of radiation-induced cataract is being called into question, raising the possibility of a risk in patients, especially children, exposed to ionizing radiation in case of repeated head CT-scans. This study aims to estimate the eye lens doses of a pediatric population exposed to repeated head CTs and to assess the feasibility of an epidemiological study. Children treated for a cholesteatoma, who had had at least one CT-scan of the middle ear before their tenth birthday, were included. Radiation exposure has been assessed from medical records and telephone interviews. Out of the 39 subjects contacted, 32 accepted to participate. A total of 76 CT-scans were retrieved from medical records. At the time of the interview (mean age: 16 years), the mean number of CT per child was 3. Cumulative mean effective and eye lens doses were 1.7mSv and 168mGy, respectively. A relatively high lens radiation dose was observed in children exposed to repeated CT-scans. Due to that exposure and despite the difficulties met when trying to reach patients' families, a large scale epidemiological study should be performed in order to assess the risk of radiation-induced cataracts associated with repeated head CT. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Meulepas, Johanna M; Ronckers, Cécile M; Merks, Johannes; Weijerman, Michel E; Lubin, Jay H; Hauptmann, Michael
2016-12-01
Recent studies linking radiation exposure from pediatric computed tomography (CT) to increased risks of leukemia and brain tumors lacked data to control for cancer susceptibility syndromes (CSS). These syndromes might be confounders because they are associated with an increased cancer risk and may increase the likelihood of pediatric CT scans. We identify CSS predisposing to leukemia and brain tumors through a systematic literature search and summarize prevalence and risk. Since empirical evidence is lacking in published literature on patterns of CT use for most types of CSS, we estimate confounding bias of relative risks (RR) for categories of radiation exposure based on expert opinion about patterns of CT scans among CSS patients. We estimate that radiation-related RRs for leukemia are not meaningfully confounded by Down syndrome, Noonan syndrome and other CSS. Moreover, tuberous sclerosis complex, von Hippel-Lindau disease, neurofibromatosis type 1 and other CSS do not meaningfully confound RRs for brain tumors. Empirical data on the use of CT scans among CSS patients is urgently needed. Our assessment indicates that associations with radiation exposure from pediatric CT scans and leukemia or brain tumors reported in previous studies are unlikely to be substantially confounded by unmeasured CSS.
Kohler, Steven W; Chen, Richard; Kagan, Alex; Helvey, Dustin W; Buccigrossi, David
2013-06-01
In order to determine the effects of implementation of an electronic medical record on rates of repeat computed tomography (CT) scanning in the emergency department (ED) setting, we analyzed the utilization of CT of the kidneys, ureters, and bladder (CT KUB) for the detection of urinary tract calculi for periods before and after the implementation of a hospital-wide electronic medical record system. Rates of repeat CT scanning within a 6-month period of previous scan were determined pre- and post-implementation and compared. Prior to implementation, there was a 6-month repeat rate of 6.2 % compared with the post-implementation period, which was associated with a 6-month repeat rate of 4.1 %. Statistical analysis using a two-sample, one-tailed t test for difference of means was associated with a p value of 0.00007. This indicates that the implementation of the electronic medical record system was associated with a 34 % decrease in 6-month repeat CT KUB scans. We conclude that the use of an electronic medical record can be associated with a decrease in utilization of unnecessary repeat CT imaging, leading to decreased cumulative lifetime risk for cancer in these patients and more efficient utilization of ED and radiologic resources.
18F-FDG uptake and its clinical relevance in primary gastric lymphoma.
Yi, Jun Ho; Kim, Seok Jin; Choi, Joon Young; Ko, Young Hyeh; Kim, Byung-Tae; Kim, Won Seog
2010-06-01
We studied the clinical relevance of (18)F-fluorodeoxyglucose ((18)F-FDG) uptake in patients with primary gastric lymphoma underwent positron emission tomography (PET)/ computed tomography (CT) scan. Forty-two patients with primary gastric lymphoma were analysed: 32 diffuse large B-cell lymphomas (DLBCL) and 10 extranodal marginal zone B-cell lymphomas of mucosa-associated lymphoid tissue (MALT lymphomas). The PET/CT scans were compared with clinical and pathologic features, and the results of CT and endoscopy. Nine patients were up-staged based on the results of their PET/CT scan compared to CT (seven DLBCLs, two MALT lymphomas) while six patients were down-staged by the PET/CT scan. The standard uptake value (SUV) was used as an indicator of a lesion with a high metabolic rate. The high SUVmax group, defined as an SUVmax >or= median value, was significantly associated with an advanced Lugano stage (p < 0.001). Three patients with DLBCL, who showed an initially high SUVmax, died of disease progression. Among 24 patients for whom follow-up PET/CT scan with endoscopy was performed, 11 patients with ulcerative or mucosal lesions showed residual (18)F-FDG uptake. All of these gastric lesions were grossly and pathologically benign lesions without evidence of lymphoma cells. In conclusion, PET/CT scan can be used in staging patients with primary gastric lymphoma; however, the residual (18)F-FDG uptake observed during follow-up should be interpreted cautiously and should be combined with endoscopy and multiple biopsies of the stomach. (c) 2009 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, M; Rosica, D; Agarwal, V
Purpose: Two separate low-dose CT scans are usually performed for attenuation correction of rest and stress N-13 ammonia PET/CT myocardial perfusion imaging (PET/CT). We utilize an automatic exposure control (AEC) technique to reduce CT radiation dose while maintaining perfusion image quality. Our goal is to assess the reproducibility of displayed CT dose index (CTDI) on same-day repeat CT scans (CT1 and CT2). Methods: Retrospectively, we reviewed CT images of PET/CT studies performed on the same day. Low-dose CT utilized AEC technique based on tube current modulation called Smart-mA. The scan parameters were 64 × 0.625mm collimation, 5mm slice thickness, 0.984more » pitch, 1-sec rotation time, 120 kVp, and noise index 50 with a range of 10–200 mA. The scan length matched with PET field of view (FOV) with the heart near the middle of axial FOV. We identified the reference slice number (RS) for an anatomical landmark (carina) and used it to estimate axial shift between two CTs. For patient size, we measured an effective diameter on the reference slice. The effect of patient positioning to CTDI was evaluated using the table height. We calculated the absolute percent difference of the CTDI (%diff) for estimation of the reproducibility. Results: The study included 168 adults with an average body-mass index of 31.72 ± 9.10 (kg/m{sup 2}) and effective diameter was 32.72 ± 4.60 cm. The average CTDI was 1.95 ± 1.40 mGy for CT1 and 1.97 ± 1.42mGy for CT2. The mean %diff was 7.8 ± 6.8%. Linear regression analysis showed a significant correlation between the table height and %diff CTDI. (r=0.82, p<0.001) Conclusion: We have shown for the first time in human subjects, using two same-day CT images, that the AEC technique in low-dose CT is reproducible within 10% and significantly depends on the patient centering.« less
Clinical Utility of Preoperative Computed Tomography in Patients With Endometrial Cancer.
Bogani, Giorgio; Gostout, Bobbie S; Dowdy, Sean C; Multinu, Francesco; Casarin, Jvan; Cliby, William A; Frigerio, Luigi; Kim, Bohyun; Weaver, Amy L; Glaser, Gretchen E; Mariani, Andrea
2017-10-01
The aim of this study was to determine the clinical utility of routine preoperative pelvic and abdominal computed tomography (CT) examinations in patients with endometrial cancer (EC). We retrospectively reviewed records from patients with EC who underwent a preoperative endometrial biopsy and had surgery at our institution from January 1999 through December 2008. In the subset with an abdominal CT scan obtained within 3 months before surgery, we evaluated the clinical utility of the CT scan. Overall, 224 patients (18%) had a preoperative endometrial biopsy and an available CT scan. Gross intra-abdominal disease was observed in 10% and 20% of patients with preoperative diagnosis of endometrioid G3 and type II EC, respectively, whereas less than 5% of patients had a preoperative diagnosis of hyperplasia or low-grade EC. When examining retroperitoneal findings, we observed that a negative CT scan of the pelvis did not exclude the presence of pelvic node metastasis. Alternately, a negative CT scan in the para-aortic area generally reduced the probability of finding para-aortic dissemination but with an overall low sensitivity (42%). However, the sensitivity for para-aortic dissemination was as high as 67% in patients with G3 endometrioid cancer. In the case of negative para-aortic nodes in the CT scan, the risk of para-aortic node metastases decreased from 18.8% to 7.5% in patients with endometrioid G3 EC. Up to 15% of patients with endometrioid G3 cancer had clinically relevant incidental findings that necessitated medical or surgical intervention. In patients with endometrioid G3 and type II EC diagnosed by the preoperative biopsy, CT scans may help guide the operative plan by facilitating preoperative identification of gross intra-abdominal disease and enlarged positive para-aortic nodes that are not detectable during physical examinations. In addition, CT may reveal other clinically relevant incidental findings.
Estimating local noise power spectrum from a few FBP-reconstructed CT scans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeng, Rongping, E-mail: rongping.zeng@fda.hhs.gov; Gavrielides, Marios A.; Petrick, Nicholas
Purpose: Traditional ways to estimate 2D CT noise power spectrum (NPS) involve an ensemble average of the power spectrums of many noisy scans. When only a few scans are available, regions of interest are often extracted from different locations to obtain sufficient samples to estimate the NPS. Using image samples from different locations ignores the nonstationarity of CT noise and thus cannot accurately characterize its local properties. The purpose of this work is to develop a method to estimate local NPS using only a few fan-beam CT scans. Methods: As a result of FBP reconstruction, the CT NPS has themore » same radial profile shape for all projection angles, with the magnitude varying with the noise level in the raw data measurement. This allows a 2D CT NPS to be factored into products of a 1D angular and a 1D radial function in polar coordinates. The polar separability of CT NPS greatly reduces the data requirement for estimating the NPS. The authors use this property and derive a radial NPS estimation method: in brief, the radial profile shape is estimated from a traditional NPS based on image samples extracted at multiple locations. The amplitudes are estimated by fitting the traditional local NPS to the estimated radial profile shape. The estimated radial profile shape and amplitudes are then combined to form a final estimate of the local NPS. We evaluate the accuracy of the radial NPS method and compared it to traditional NPS methods in terms of normalized mean squared error (NMSE) and signal detectability index. Results: For both simulated and real CT data sets, the local NPS estimated with no more than six scans using the radial NPS method was very close to the reference NPS, according to the metrics of NMSE and detectability index. Even with only two scans, the radial NPS method was able to achieve a fairly good accuracy. Compared to those estimated using traditional NPS methods, the accuracy improvement was substantial when a few scans were available. Conclusions: The radial NPS method was shown to be accurate and efficient in estimating the local NPS of FBP-reconstructed 2D CT images. It presents strong advantages over traditional NPS methods when the number of scans is limited and can be extended to estimate the in-plane NPS of cone-beam CT and multislice helical CT scans.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fried, David V.; Graduate School of Biomedical Sciences, The University of Texas Health Science Center at Houston, Houston, Texas; Tucker, Susan L.
2014-11-15
Purpose: To determine whether pretreatment CT texture features can improve patient risk stratification beyond conventional prognostic factors (CPFs) in stage III non-small cell lung cancer (NSCLC). Methods and Materials: We retrospectively reviewed 91 cases with stage III NSCLC treated with definitive chemoradiation therapy. All patients underwent pretreatment diagnostic contrast enhanced computed tomography (CE-CT) followed by 4-dimensional CT (4D-CT) for treatment simulation. We used the average-CT and expiratory (T50-CT) images from the 4D-CT along with the CE-CT for texture extraction. Histogram, gradient, co-occurrence, gray tone difference, and filtration-based techniques were used for texture feature extraction. Penalized Cox regression implementing cross-validation wasmore » used for covariate selection and modeling. Models incorporating texture features from the 33 image types and CPFs were compared to those with models incorporating CPFs alone for overall survival (OS), local-regional control (LRC), and freedom from distant metastases (FFDM). Predictive Kaplan-Meier curves were generated using leave-one-out cross-validation. Patients were stratified based on whether their predicted outcome was above or below the median. Reproducibility of texture features was evaluated using test-retest scans from independent patients and quantified using concordance correlation coefficients (CCC). We compared models incorporating the reproducibility seen on test-retest scans to our original models and determined the classification reproducibility. Results: Models incorporating both texture features and CPFs demonstrated a significant improvement in risk stratification compared to models using CPFs alone for OS (P=.046), LRC (P=.01), and FFDM (P=.005). The average CCCs were 0.89, 0.91, and 0.67 for texture features extracted from the average-CT, T50-CT, and CE-CT, respectively. Incorporating reproducibility within our models yielded 80.4% (±3.7% SD), 78.3% (±4.0% SD), and 78.8% (±3.9% SD) classification reproducibility in terms of OS, LRC, and FFDM, respectively. Conclusions: Pretreatment tumor texture may provide prognostic information beyond that obtained from CPFs. Models incorporating feature reproducibility achieved classification rates of ∼80%. External validation would be required to establish texture as a prognostic factor.« less
Micro computed tomography (CT) scanned anatomical gateway to insect pest bioinformatics
USDA-ARS?s Scientific Manuscript database
An international collaboration to establish an interactive Digital Video Library for a Systems Biology Approach to study the Asian citrus Psyllid and psyllid genomics/proteomics interactions is demonstrated. Advances in micro-CT, digital computed tomography (CT) scan uses X-rays to make detailed pic...
Different methods for anatomical targeting.
Iacopino, D G; Conti, A; Angileri, F F; Tomasello, F
2003-03-01
Several procedures are used in the different neurosurgical centers in order to perform stereotactic surgery for movement disorders. At the moment no procedure can really be considered superior to the other. We contribute with our experience of targeting method. Ten patients were selected, in accordance to the guidelines for the treatment of Parkinson disease, and operated by several methods including pallidotomy, bilateral insertion of chronic deep brain electrodes within the internal pallidum and in the subthalamic nucleus (18 procedures). in each patient an MR scan was performed the day before surgery. Scans were performed axially parallel to the intercommissural line. The operating day a contrast CT scan was performed under stereotactic conditions. after digitalization of the MRI images, it was possible to visualize the surgical target and to relate it to parenchimal and vascular anatomic structures readable at the CT examination. The CT scan obtained was confronted with the MR previously performed, the geometrical relation between the different parenchimal and vascular structures and the selected targets were obtained. Stereotactic coordinates were obtained on the CT examination. It was possible to calculate the position of the subthalamic nucleus and of the internal pallidum on the CT scan, not only relating to the intercommissural line, but considering also the neurovascular structures displayed both on the MRI and the CT scans. The technique that our group presents consist in an integration between information derived from the CT and the MR techniques, so that we can benefit from the advantages of both methods and overcome the disadvantages.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dowling, Jason A., E-mail: jason.dowling@csiro.au; University of Newcastle, Callaghan, New South Wales; Sun, Jidi
Purpose: To validate automatic substitute computed tomography CT (sCT) scans generated from standard T2-weighted (T2w) magnetic resonance (MR) pelvic scans for MR-Sim prostate treatment planning. Patients and Methods: A Siemens Skyra 3T MR imaging (MRI) scanner with laser bridge, flat couch, and pelvic coil mounts was used to scan 39 patients scheduled for external beam radiation therapy for localized prostate cancer. For sCT generation a whole-pelvis MRI scan (1.6 mm 3-dimensional isotropic T2w SPACE [Sampling Perfection with Application optimized Contrasts using different flip angle Evolution] sequence) was acquired. Three additional small field of view scans were acquired: T2w, T2*w, and T1wmore » flip angle 80° for gold fiducials. Patients received a routine planning CT scan. Manual contouring of the prostate, rectum, bladder, and bones was performed independently on the CT and MR scans. Three experienced observers contoured each organ on MRI, allowing interobserver quantification. To generate a training database, each patient CT scan was coregistered to their whole-pelvis T2w using symmetric rigid registration and structure-guided deformable registration. A new multi-atlas local weighted voting method was used to generate automatic contours and sCT results. Results: The mean error in Hounsfield units between the sCT and corresponding patient CT (within the body contour) was 0.6 ± 14.7 (mean ± 1 SD), with a mean absolute error of 40.5 ± 8.2 Hounsfield units. Automatic contouring results were very close to the expert interobserver level (Dice similarity coefficient): prostate 0.80 ± 0.08, bladder 0.86 ± 0.12, rectum 0.84 ± 0.06, bones 0.91 ± 0.03, and body 1.00 ± 0.003. The change in monitor units between the sCT-based plans relative to the gold standard CT plan for the same dose prescription was found to be 0.3% ± 0.8%. The 3-dimensional γ pass rate was 1.00 ± 0.00 (2 mm/2%). Conclusions: The MR-Sim setup and automatic sCT generation methods using standard MR sequences generates realistic contours and electron densities for prostate cancer radiation therapy dose planning and digitally reconstructed radiograph generation.« less
Ultrafast CT scanning of an oak log for internal defects
Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder
1989-01-01
Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...
Braunschweig, Carol A; Sheean, Patricia M; Peterson, Sarah J; Gomez Perez, Sandra; Freels, Sally; Troy, Karen L; Ajanaku, Folabomi C; Patel, Ankur; Sclamberg, Joy S; Wang, Zebin
2014-09-01
Assessment of nutritional status in intensive care unit (ICU) patients is limited. Computed tomography (CT) scans that include the first to fifth lumbar region completed for diagnostic purposes measures fat and lean body mass (LBM) depots and are frequently done in ICU populations and can be used to quantify fat and LBM depots. The purpose of this study was to assess if these scans could measure change in skeletal muscle (SKT), visceral adipose (VAT), and intermuscular adipose (IMAT) tissue and to examine the association between the amount of energy and protein received and changes in these depots. Cross-sectional area of SKT, VAT, and IMAT from CT scans at the third lumbar region was quantified at 2 time points (CT1 and CT2). Change scores between CT1 and CT2 for each of these depots and the percentage of estimated energy/protein needs received were determined in 33 adults that with acute respiratory failure. Descriptive statistics and multiple regression was used to evaluate the influence of baseline characteristics and the percentage energy/protein needs received between CT1 and CT2 on percentage change/day between CT1 and CT2 on SKM, IMAT, and VAT. Participants were on average (SD) 59.7 (16) years old, received 41% of energy and 57% of protein needs. The average time between CT1 and CT2 was 10 (5) days. SKM declined 0.49%/day (men P = .07, women P = .09) and percentage of energy needs received reduced loss (β = 0.024, P = .03). No change in VAT or IMAT occurred. CT scans can be exploited to assess change in body composition in ICU patients and may assist in detecting the causal link between nutritional support and outcomes in future clinical trials. © 2013 American Society for Parenteral and Enteral Nutrition.
CT dose reduction in children.
Vock, Peter
2005-11-01
World wide, the number of CT studies in children and the radiation exposure by CT increases. The same energy dose has a greater biological impact in children than in adults, and scan parameters have to be adapted to the smaller diameter of the juvenile body. Based on seven rules, a practical approach to paediatric CT is shown: Justification and patient preparation are important steps before scanning, and they differ from the preparation of adult patients. The subsequent choice of scan parameters aims at obtaining the minimal signal-to-noise ratio and volume coverage needed in a specific medical situation; exposure can be divided in two aspects: the CT dose index determining energy deposition per rotation and the dose-length product (DLP) determining the volume dose. DLP closely parallels the effective dose, the best parameter of the biological impact. Modern scanners offer dose modulation to locally minimise exposure while maintaining image quality. Beyond the selection of the physical parameters, the dose can be kept low by scanning the minimal length of the body and by avoiding any non-qualified repeated scanning of parts of the body. Following these rules, paediatric CT examinations of good quality can be obtained at a reasonable cost of radiation exposure.
A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol.
Carnes, Greg; Gaede, Stewart; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim
2009-04-07
Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy chaining' all couch positions using the selected images until an entire 3D volume was produced. The algorithm produced 16 phase volumes to complete a 4D-CT dataset. Additional 4D-CT datasets were also produced using external marker amplitude and phase angle sorting methods. The image quality of the volumes produced by the different methods was quantified by calculating the mean difference of the sorted overlapping slices from adjacent couch positions. The NCC sorted images showed a significant decrease in the mean difference (p < 0.01) for the five patients.
Dosimetry in MARS spectral CT: TOPAS Monte Carlo simulations and ion chamber measurements.
Lu, Gray; Marsh, Steven; Damet, Jerome; Carbonez, Pierre; Laban, John; Bateman, Christopher; Butler, Anthony; Butler, Phil
2017-06-01
Spectral computed tomography (CT) is an up and coming imaging modality which shows great promise in revealing unique diagnostic information. Because this imaging modality is based on X-ray CT, it is of utmost importance to study the radiation dose aspects of its use. This study reports on the implementation and evaluation of a Monte Carlo simulation tool using TOPAS for estimating dose in a pre-clinical spectral CT scanner known as the MARS scanner. Simulated estimates were compared with measurements from an ionization chamber. For a typical MARS scan, TOPAS estimated for a 30 mm diameter cylindrical phantom a CT dose index (CTDI) of 29.7 mGy; CTDI was measured by ion chamber to within 3% of TOPAS estimates. Although further development is required, our investigation of TOPAS for estimating MARS scan dosimetry has shown its potential for further study of spectral scanning protocols and dose to scanned objects.
A rare adult renal neuroblastoma better imaged by 18F-FDG than by 68Ga-dotanoc in the PET/CT scan.
Jain, Tarun Kumar; Singh, Sharwan Kumar; Sood, Ashwani; Ashwathanarayama, Abhiram Gj; Basher, Rajender Kumar; Shukla, Jaya; Mittal, Bhagwant Rai
2017-01-01
Primary renal neuroblastoma is an uncommon tumor in children and extremely rare in adults. We present a case of a middle aged female having a large retroperitoneal mass involving the right kidney with features of neuroblastoma on pre-operative histopathology. Whole-body fluorine-18-fluoro-deoxyglucose positron emission tomography ( 18 F-FDG PET/CT) and 68 Ga-dotanoc PET/CT scans performed for staging and therapeutic potential revealed a tracer avid mass replacing the right kidney and also pelvic lymph nodes. The 18 F-FDG PET/CT scan showed better both the primary lesion and the metastases in the pelvic lymph nodes than the 68 Ga-dotanoc scan supporting diagnosis and treatment planning.
Pore-scale Simulation and Imaging of Multi-phase Flow and Transport in Porous Media (Invited)
NASA Astrophysics Data System (ADS)
Crawshaw, J.; Welch, N.; Daher, I.; Yang, J.; Shah, S.; Grey, F.; Boek, E.
2013-12-01
We combine multi-scale imaging and computer simulation of multi-phase flow and reactive transport in rock samples to enhance our fundamental understanding of long term CO2 storage in rock formations. The imaging techniques include Confocal Laser Scanning Microscopy (CLSM), micro-CT and medical CT scanning, with spatial resolutions ranging from sub-micron to mm respectively. First, we report a new sample preparation technique to study micro-porosity in carbonates using CLSM in 3 dimensions. Second, we use micro-CT scanning to generate high resolution 3D pore space images of carbonate and cap rock samples. In addition, we employ micro-CT to image the processes of evaporation in fractures and cap rock degradation due to exposure to CO2 flow. Third, we use medical CT scanning to image spontaneous imbibition in carbonate rock samples. Our imaging studies are complemented by computer simulations of multi-phase flow and transport, using the 3D pore space images obtained from the scanning experiments. We have developed a massively parallel lattice-Boltzmann (LB) code to calculate the single phase flow field in these pore space images. The resulting flow fields are then used to calculate hydrodynamic dispersion using a novel scheme to predict probability distributions for molecular displacements using the LB method and a streamline algorithm, modified for optimal solid boundary conditions. We calculate solute transport on pore-space images of rock cores with increasing degree of heterogeneity: a bead pack, Bentheimer sandstone and Portland carbonate. We observe that for homogeneous rock samples, such as bead packs, the displacement distribution remains Gaussian with time increasing. In the more heterogeneous rocks, on the other hand, the displacement distribution develops a stagnant part. We observe that the fraction of trapped solute increases from the beadpack (0 %) to Bentheimer sandstone (1.5 %) to Portland carbonate (8.1 %), in excellent agreement with PFG-NMR experiments. We then use our preferred multi-phase model to directly calculate flow in pore space images of two different sandstones and observe excellent agreement with experimental relative permeabilities. Also we calculate cluster size distributions in good agreement with experimental studies. Our analysis shows that the simulations are able to predict both multi-phase flow and transport properties directly on large 3D pore space images of real rocks. Pore space images, left and velocity distributions, right (Yang and Boek, 2013)
Santos, Priscila L; Brito, Renan G; Oliveira, Marlange A; Quintans, Jullyana S S; Guimarães, Adriana G; Santos, Márcio R V; Menezes, Paula P; Serafini, Mairim R; Menezes, Irwin R A; Coutinho, Henrique D M; Araújo, Adriano A S; Quintans-Júnior, Lucindo J
2016-08-15
Citronellal (CT) is a monoterpene with antinociceptive acute effect. β-Cyclodextrin (βCD) has enhanced the analgesic effect of various substances. To evaluate the effect of CT both complexed in β-cyclodextrin (CT-βCD) and non-complexed, in a chronic muscle pain model (CMP) in mice. The complex containing CT in βCD was obtained and characterized in the laboratory. The anti-hyperalgesic effect of CT and CT-βCD was evaluated in a pre-clinical in vivo study in a murine CMP. The complex was characterized through differential scanning calorimetry, derivative thermogravimetry, moisture determination, infrared spectroscopy and scanning electron microscopy. Male Swiss mice were pre-treated with CT (50mg/kg, po), CT-βCD (50mg/kg, po), vehicle (isotonic saline, po) or standard drug (tramadol4 mg/kg, ip). 60 min after the treatment and then each 1h, the mechanic hyperalgesia was evaluated to obtain the time effect. In addition, the muscle strength using grip strength meter and hyperalgesia were also performed daily, for 7 days. We assessed by immunofluorescence for Fos protein on brains and spinal cords of mice. The involvement of the CT with the glutamatergic system was studied with molecular docking. All characterization methods showed the CT-βCD complexation. CT-induced anti-hyperalgesic effect lasted until 6h (p <0.001) while CT-βCD lasted until 8h (p <0.001vs vehicle and p <0.001vs CT from the 6th h). CT-βCD reduced mechanical hyperalgesia on all days of treatment (p <0.05), without changing muscle strength. Periaqueductal gray (p <0.01) and rostroventromedular area (p <0.05) showed significant increase in the Fos protein expression while in the spinal cord, there was a reduction (p <0.001). CT showed favorable energy binding (-5.6 and -6.1) to GluR2-S1S2J protein based in the docking score function. We can suggest that βCD improved the anti-hyperalgesic effect of CT, and that effect seems to involve the descending pain-inhibitory mechanisms, with a possible interaction of the glutamate receptors, which are considered as promising molecules for the management of chronic pain such as CMP. Copyright © 2016 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Tonghe; Zhu, Lei
2016-09-01
Conventional dual-energy CT (DECT) reconstruction requires two full-size projection datasets with two different energy spectra. In this study, we propose an iterative algorithm to enable a new data acquisition scheme which requires one full scan and a second sparse-view scan for potential reduction in imaging dose and engineering cost of DECT. A bilateral filter is calculated as a similarity matrix from the first full-scan CT image to quantify the similarity between any two pixels, which is assumed unchanged on a second CT image since DECT scans are performed on the same object. The second CT image from reduced projections is reconstructed by an iterative algorithm which updates the image by minimizing the total variation of the difference between the image and its filtered image by the similarity matrix under data fidelity constraint. As the redundant structural information of the two CT images is contained in the similarity matrix for CT reconstruction, we refer to the algorithm as structure preserving iterative reconstruction (SPIR). The proposed method is evaluated on both digital and physical phantoms, and is compared with the filtered-backprojection (FBP) method, the conventional total-variation-regularization-based algorithm (TVR) and prior-image-constrained-compressed-sensing (PICCS). SPIR with a second 10-view scan reduces the image noise STD by a factor of one order of magnitude with same spatial resolution as full-view FBP image. SPIR substantially improves over TVR on the reconstruction accuracy of a 10-view scan by decreasing the reconstruction error from 6.18% to 1.33%, and outperforms TVR at 50 and 20-view scans on spatial resolution with a higher frequency at the modulation transfer function value of 10% by an average factor of 4. Compared with the 20-view scan PICCS result, the SPIR image has 7 times lower noise STD with similar spatial resolution. The electron density map obtained from the SPIR-based DECT images with a second 10-view scan has an average error of less than 1%.
Pitfalls of CT for deep neck abscess imaging assessment: a retrospective review of 162 cases.
Chuang, S Y; Lin, H T; Wen, Y S; Hsu, F J
2013-01-01
To investigate the diagnostic value of contrast-enhanced computed tomography (CT) for the prediction of deep neck abscesses in different deep neck spaces and to evaluate the false-positive results. We retrospectively analysed the clinical charts, CT examinations, surgical findings, bacteriology, pathological examinations and complications of hospitalised patients with a diagnosis of deep neck abscess from 2004 to 2010. The positive predictive values (PPV) for the prediction of abscesses by CT scan in different deep neck spaces were calculated individually on the basis of surgical findings. A total of 162 patients were included in this study. All patients received both intravenous antibiotics and surgical drainage. The parapharyngeal space was the most commonly involved space. The overall PPV for the prediction of deep neck abscess with contrast-enhanced CT was 79.6%. The PPV was 91.3% when more than one deep neck space was involved but only 50.0% in patients with isolated retropharyngeal abscesses. In the false-positive group, cellulitis was the most common final result, followed by cystic degeneration of cervical metastases. Five specimens taken intra-operatively revealed malignancy and four of these were not infected. There are some limitations affecting the differentiation of abscesses and cellulitis, particularly in the retropharyngeal space. A central necrotic cervical metastatic lymph node may sometimes also mimic a simple pyogenic deep neck abscess on both clinical pictures and CT images. Routine biopsy of the tissue must be performed during surgical drainage.
Sarma, Debanga; Barua, Sasanka K; Rajeev, T P; Baruah, Saumar J
2012-10-01
Nuclear renal scan is currently the gold standard imaging study to determine differential renal function. We propose helical CT as single modality for both the anatomical and functional evaluation of kidney with impaired function. In the present study renal parenchymal volume is measured and percent total renal volume is used as a surrogate marker for differential renal function. The objective of this study is to correlate between differential renal function estimation using CT-based renal parenchymal volume measurement with differential renal function estimation using (99m)TC - DTPA renal scan. Twenty-one patients with unilateral obstructive uropathy were enrolled in this prospective comparative study. They were subjected to (99m)Tc - DTPA renal scan and 64 slice helical CT scan which estimates the renal volume depending on the reconstruction of arterial phase images followed by volume rendering and percent renal volume was calculated. Percent renal volume was correlated with percent renal function, as determined by nuclear renal scan using Pearson coefficient. RESULTS AND OBSERVATION: A strong correlation is observed between percent renal volume and percent renal function in obstructed units (r = 0.828, P < 0.001) as well as in nonobstructed units (r = 0.827, P < 0.001). There is a strong correlation between percent renal volume determined by CT scan and percent renal function determined by (99m)TC - DTPA renal scan both in obstructed and in normal units. CT-based percent renal volume can be used as a single radiological tests for both functional and anatomical assessment of impaired renal units.
Selected PET radiomic features remain the same.
Tsujikawa, Tetsuya; Tsuyoshi, Hideaki; Kanno, Masafumi; Yamada, Shizuka; Kobayashi, Masato; Narita, Norihiko; Kimura, Hirohiko; Fujieda, Shigeharu; Yoshida, Yoshio; Okazawa, Hidehiko
2018-04-17
We investigated whether PET radiomic features are affected by differences in the scanner, scan protocol, and lesion location using 18 F-FDG PET/CT and PET/MR scans. SUV, TMR, skewness, kurtosis, entropy, and homogeneity strongly correlated between PET/CT and PET/MR images. SUVs were significantly higher on PET/MR 0-2 min and PET/MR 0-10 min than on PET/CT in gynecological cancer ( p = 0.008 and 0.008, respectively), whereas no significant difference was observed between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images in oral cavity/oropharyngeal cancer. TMRs on PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min increased in this order in gynecological cancer and oral cavity/oropharyngeal cancer. In contrast to conventional and histogram indices, 4 textural features (entropy, homogeneity, SRE, and LRE) were not significantly different between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images. 18 F-FDG PET radiomic features strongly correlated between PET/CT and PET/MR images. Dixon-based attenuation correction on PET/MR images underestimated tumor tracer uptake more significantly in oral cavity/oropharyngeal cancer than in gynecological cancer. 18 F-FDG PET textural features were affected less by differences in the scanner and scan protocol than conventional and histogram features, possibly due to the resampling process using a medium bin width. Eight patients with gynecological cancer and 7 with oral cavity/oropharyngeal cancer underwent a whole-body 18 F-FDG PET/CT scan and regional PET/MR scan in one day. PET/MR scans were performed for 10 minutes in the list mode, and PET/CT and 0-2 min and 0-10 min PET/MR images were reconstructed. The standardized uptake value (SUV), tumor-to-muscle SUV ratio (TMR), skewness, kurtosis, entropy, homogeneity, short-run emphasis (SRE), and long-run emphasis (LRE) were compared between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images.
Pan, Yuxi; Qiu, Rui; Gao, Linfeng; Ge, Chaoyong; Zheng, Junzheng; Xie, Wenzhang; Li, Junli
2014-09-21
With the rapidly growing number of CT examinations, the consequential radiation risk has aroused more and more attention. The average dose in each organ during CT scans can only be obtained by using Monte Carlo simulation with computational phantoms. Since children tend to have higher radiation sensitivity than adults, the radiation dose of pediatric CT examinations requires special attention and needs to be assessed accurately. So far, studies on organ doses from CT exposures for pediatric patients are still limited. In this work, a 1-year-old computational phantom was constructed. The body contour was obtained from the CT images of a 1-year-old physical phantom and the internal organs were deformed from an existing Chinese reference adult phantom. To ensure the organ locations in the 1-year-old computational phantom were consistent with those of the physical phantom, the organ locations in 1-year-old computational phantom were manually adjusted one by one, and the organ masses were adjusted to the corresponding Chinese reference values. Moreover, a CT scanner model was developed using the Monte Carlo technique and the 1-year-old computational phantom was applied to estimate organ doses derived from simulated CT exposures. As a result, a database including doses to 36 organs and tissues from 47 single axial scans was built. It has been verified by calculation that doses of axial scans are close to those of helical scans; therefore, this database could be applied to helical scans as well. Organ doses were calculated using the database and compared with those obtained from the measurements made in the physical phantom for helical scans. The differences between simulation and measurement were less than 25% for all organs. The result shows that the 1-year-old phantom developed in this work can be used to calculate organ doses in CT exposures, and the dose database provides a method for the estimation of 1-year-old patient doses in a variety of CT examinations.
NASA Astrophysics Data System (ADS)
Pan, Yuxi; Qiu, Rui; Gao, Linfeng; Ge, Chaoyong; Zheng, Junzheng; Xie, Wenzhang; Li, Junli
2014-09-01
With the rapidly growing number of CT examinations, the consequential radiation risk has aroused more and more attention. The average dose in each organ during CT scans can only be obtained by using Monte Carlo simulation with computational phantoms. Since children tend to have higher radiation sensitivity than adults, the radiation dose of pediatric CT examinations requires special attention and needs to be assessed accurately. So far, studies on organ doses from CT exposures for pediatric patients are still limited. In this work, a 1-year-old computational phantom was constructed. The body contour was obtained from the CT images of a 1-year-old physical phantom and the internal organs were deformed from an existing Chinese reference adult phantom. To ensure the organ locations in the 1-year-old computational phantom were consistent with those of the physical phantom, the organ locations in 1-year-old computational phantom were manually adjusted one by one, and the organ masses were adjusted to the corresponding Chinese reference values. Moreover, a CT scanner model was developed using the Monte Carlo technique and the 1-year-old computational phantom was applied to estimate organ doses derived from simulated CT exposures. As a result, a database including doses to 36 organs and tissues from 47 single axial scans was built. It has been verified by calculation that doses of axial scans are close to those of helical scans; therefore, this database could be applied to helical scans as well. Organ doses were calculated using the database and compared with those obtained from the measurements made in the physical phantom for helical scans. The differences between simulation and measurement were less than 25% for all organs. The result shows that the 1-year-old phantom developed in this work can be used to calculate organ doses in CT exposures, and the dose database provides a method for the estimation of 1-year-old patient doses in a variety of CT examinations.
Toelly, Andrea; Bardach, Constanze; Weber, Michael; Gong, Rui; Lai, Yanbo; Wang, Pei; Guo, Yulin; Kirschke, Jan; Baum, Thomas; Gruber, Michael
2017-06-01
Aim To evaluate the differences in phantom-less bone mineral density (BMD) measurements in contrast-enhanced routine MDCT scans at different contrast phases, and to develop an algorithm for calculating a reliable BMD value. Materials and Methods 112 postmenopausal women from the age of 40 to 77 years (mean age: 57.31 years; SD 9.61) who underwent a clinically indicated MDCT scan, consisting of an unenhanced, an arterial, and a venous phase, were included. A retrospective analysis of the BMD values of the Th12 to L4 vertebrae in each phase was performed using a commercially available phantom-less measurement tool. Results The mean BMD value in the unenhanced MDCT scans was 79.76 mg/cm³ (SD 31.20), in the arterial phase it was 85.09 mg/cm³ (SD 31.61), and in the venous phase it was 86.18 mg/cm³ (SD 31.30). A significant difference (p < 0.001) was found between BMD values on unenhanced and contrast-enhanced MDCT scans. There was no significant difference between BMD values in the arterial and venous phases (p = 0.228). The following conversion formulas were calculated using linear regression: unenhanced BMD = -2.287 + 0.964 * [arterial BMD value] and -4.517 + 0.978 * [venous BMD value]. The intrarater agreement of BMD measurements was calculated with an intraclass correlation (ICC) of 0.984 and the interobserver reliability was calculated with an ICC of 0.991. Conclusion Phantom-less BMD measurements in contrast-enhanced MDCT scans result in increased mean BMD values, but, with the formulas applied in our study, a reliable BMD value can be calculated. However, the mean BMD values did not differ significantly between the arterial and venous phases. Key points · BMD can be assessed on routine CT scans using a phantom-less tool.. · i. v. contrast agent significantly elevates BMD values measured on routine CT scans.. · BMD values measured in the arterial and venous phase did not differ significantly.. · Conversion formulas were defined for the calculation of a reliable BMD.. · The phantom-less tool showed good reliability and is a promising method.. Citation Format · Toelly A, Bardach C, Weber M et al. Influence of Contrast Media on Bone Mineral Density (BMD) Measurements from Routine Contrast-Enhanced MDCT Datasets using a Phantom-less BMD Measurement Tool. Fortschr Röntgenstr 2017; 189: 537 - 543. © Georg Thieme Verlag KG Stuttgart · New York.
Holder, Jourdan T; Kessler, David M; Noble, Jack H; Gifford, René H; Labadie, Robert F
2018-06-01
To quantify and compare the number of cochlear implant (CI) electrodes found to be extracochlear on postoperative computerized tomography (CT) scans, the number of basal electrodes deactivated during standard CI mapping (without knowledge of the postoperative CT scan), and the extent of electrode insertion noted by the surgeon. Retrospective. Academic Medical Center. Two hundred sixty-two patients underwent standard cochlear implantation and postoperative temporal bone CT scanning. Scans were analyzed to determine the number of extracochlear electrodes. Standard CI programming had been completed without knowledge of the extracochlear electrodes identified on the CT. These standard CI maps were reviewed to record the number of deactivated basal electrodes. Lastly, each operative report was reviewed to record the extent of reported electrode insertion. 13.4% (n = 35) of CIs were found to have at least one electrode outside of the cochlea on the CT scan. Review of CI mapping indicated that audiologists had deactivated extracochlear electrodes in 60% (21) of these cases. Review of operative reports revealed that surgeons correctly indicated the number of extracochlear electrodes in 6% (2) of these cases. Extracochlear electrodes were correctly identified audiologically in 60% of cases and in surgical reports in 6% of cases; however, it is possible that at least a portion of these cases involved postoperative electrode migration. Given these findings, postoperative CT scans can provide information regarding basal electrode location, which could help improve programming accuracy, associated frequency allocation, and audibility with appropriate deactivation of extracochlear electrodes.
Spotting L3 slice in CT scans using deep convolutional network and transfer learning.
Belharbi, Soufiane; Chatelain, Clément; Hérault, Romain; Adam, Sébastien; Thureau, Sébastien; Chastan, Mathieu; Modzelewski, Romain
2017-08-01
In this article, we present a complete automated system for spotting a particular slice in a complete 3D Computed Tomography exam (CT scan). Our approach does not require any assumptions on which part of the patient's body is covered by the scan. It relies on an original machine learning regression approach. Our models are learned using the transfer learning trick by exploiting deep architectures that have been pre-trained on imageNet database, and therefore it requires very little annotation for its training. The whole pipeline consists of three steps: i) conversion of the CT scans into Maximum Intensity Projection (MIP) images, ii) prediction from a Convolutional Neural Network (CNN) applied in a sliding window fashion over the MIP image, and iii) robust analysis of the prediction sequence to predict the height of the desired slice within the whole CT scan. Our approach is applied to the detection of the third lumbar vertebra (L3) slice that has been found to be representative to the whole body composition. Our system is evaluated on a database collected in our clinical center, containing 642 CT scans from different patients. We obtained an average localization error of 1.91±2.69 slices (less than 5 mm) in an average time of less than 2.5 s/CT scan, allowing integration of the proposed system into daily clinical routines. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pearce, Mark S; Salotti, Jane A; Little, Mark P; McHugh, Kieran; Lee, Choonsik; Kim, Kwang Pyo; Howe, Nicola L; Ronckers, Cecile M; Rajaraman, Preetha; Craft, Alan W; Parker, Louise; de González, Amy Berrington
2012-01-01
Summary Background Although CT scans are very useful clinically, potential cancer risks exist from associated ionising radiation, in particular for children who are more radiosensitive than adults. We aimed to assess the excess risk of leukaemia and brain tumours after CT scans in a cohort of children and young adults. Methods In our retrospective cohort study, we included patients without previous cancer diagnoses who were first examined with CT in National Health Service (NHS) centres in England, Wales, or Scotland (Great Britain) between 1985 and 2002, when they were younger than 22 years of age. We obtained data for cancer incidence, mortality, and loss to follow-up from the NHS Central Registry from Jan 1, 1985, to Dec 31, 2008. We estimated absorbed brain and red bone marrow doses per CT scan in mGy and assessed excess incidence of leukaemia and brain tumours cancer with Poisson relative risk models. To avoid inclusion of CT scans related to cancer diagnosis, follow-up for leukaemia began 2 years after the first CT and for brain tumours 5 years after the first CT. Findings During follow-up, 74 of 178 604 patients were diagnosed with leukaemia and 135 of 176 587 patients were diagnosed with brain tumours. We noted a positive association between radiation dose from CT scans and leukaemia (excess relative risk [ERR] per mGy 0·036, 95% CI 0·005–0·120; p=0·0097) and brain tumours (0·023, 0·010–0·049; p<0·0001). Compared with patients who received a dose of less than 5 mGy, the relative risk of leukaemia for patients who received a cumulative dose of at least 30 mGy (mean dose 51·13 mGy) was 3·18 (95% CI 1·46–6·94) and the relative risk of brain cancer for patients who received a cumulative dose of 50–74 mGy (mean dose 60·42 mGy) was 2·82 (1·33–6·03). Interpretation Use of CT scans in children to deliver cumulative doses of about 50 mGy might almost triple the risk of leukaemia and doses of about 60 mGy might triple the risk of brain cancer. Because these cancers are relatively rare, the cumulative absolute risks are small: in the 10 years after the first scan for patients younger than 10 years, one excess case of leukaemia and one excess case of brain tumour per 10 000 head CT scans is estimated to occur. Nevertheless, although clinical benefits should outweigh the small absolute risks, radiation doses from CT scans ought to be kept as low as possible and alternative procedures, which do not involve ionising radiation, should be considered if appropriate. Funding US National Cancer Institute and UK Department of Health. PMID:22681860
Pearce, Mark S; Salotti, Jane A; Little, Mark P; McHugh, Kieran; Lee, Choonsik; Kim, Kwang Pyo; Howe, Nicola L; Ronckers, Cecile M; Rajaraman, Preetha; Sir Craft, Alan W; Parker, Louise; Berrington de González, Amy
2012-08-04
Although CT scans are very useful clinically, potential cancer risks exist from associated ionising radiation, in particular for children who are more radiosensitive than adults. We aimed to assess the excess risk of leukaemia and brain tumours after CT scans in a cohort of children and young adults. In our retrospective cohort study, we included patients without previous cancer diagnoses who were first examined with CT in National Health Service (NHS) centres in England, Wales, or Scotland (Great Britain) between 1985 and 2002, when they were younger than 22 years of age. We obtained data for cancer incidence, mortality, and loss to follow-up from the NHS Central Registry from Jan 1, 1985, to Dec 31, 2008. We estimated absorbed brain and red bone marrow doses per CT scan in mGy and assessed excess incidence of leukaemia and brain tumours cancer with Poisson relative risk models. To avoid inclusion of CT scans related to cancer diagnosis, follow-up for leukaemia began 2 years after the first CT and for brain tumours 5 years after the first CT. During follow-up, 74 of 178,604 patients were diagnosed with leukaemia and 135 of 176,587 patients were diagnosed with brain tumours. We noted a positive association between radiation dose from CT scans and leukaemia (excess relative risk [ERR] per mGy 0·036, 95% CI 0·005-0·120; p=0·0097) and brain tumours (0·023, 0·010-0·049; p<0·0001). Compared with patients who received a dose of less than 5 mGy, the relative risk of leukaemia for patients who received a cumulative dose of at least 30 mGy (mean dose 51·13 mGy) was 3·18 (95% CI 1·46-6·94) and the relative risk of brain cancer for patients who received a cumulative dose of 50-74 mGy (mean dose 60·42 mGy) was 2·82 (1·33-6·03). Use of CT scans in children to deliver cumulative doses of about 50 mGy might almost triple the risk of leukaemia and doses of about 60 mGy might triple the risk of brain cancer. Because these cancers are relatively rare, the cumulative absolute risks are small: in the 10 years after the first scan for patients younger than 10 years, one excess case of leukaemia and one excess case of brain tumour per 10,000 head CT scans is estimated to occur. Nevertheless, although clinical benefits should outweigh the small absolute risks, radiation doses from CT scans ought to be kept as low as possible and alternative procedures, which do not involve ionising radiation, should be considered if appropriate. US National Cancer Institute and UK Department of Health. Copyright © 2012 Elsevier Ltd. All rights reserved.
Are CT Scans Safe? Is It True That CT Scans May Increase My Risk of Cancer?
... products: Computed tomography (CT). U.S. Food and Drug Administration. http://www.fda.gov/Radiation-EmittingProducts/RadiationEmittingProductsandProcedures/MedicalImaging/MedicalX-Rays/ucm115317.htm. Accessed Jan. 19, 2018. Lee C, et al. Radiation-related risks of ...
Scout-view Assisted Interior Micro-CT
Sen Sharma, Kriti; Holzner, Christian; Vasilescu, Dragoş M.; Jin, Xin; Narayanan, Shree; Agah, Masoud; Hoffman, Eric A.; Yu, Hengyong; Wang, Ge
2013-01-01
Micro computed tomography (micro-CT) is a widely-used imaging technique. A challenge of micro-CT is to quantitatively reconstruct a sample larger than the field-of-view (FOV) of the detector. This scenario is characterized by truncated projections and associated image artifacts. However, for such truncated scans, a low resolution scout scan with an increased FOV is frequently acquired so as to position the sample properly. This study shows that the otherwise discarded scout scans can provide sufficient additional information to uniquely and stably reconstruct the interior region of interest. Two interior reconstruction methods are designed to utilize the multi-resolution data without a significant computational overhead. While most previous studies used numerically truncated global projections as interior data, this study uses truly hybrid scans where global and interior scans were carried out at different resolutions. Additionally, owing to the lack of standard interior micro-CT phantoms, we designed and fabricated novel interior micro-CT phantoms for this study to provide means of validation for our algorithms. Finally, two characteristic samples from separate studies were scanned to show the effect of our reconstructions. The presented methods show significant improvements over existing reconstruction algorithms. PMID:23732478
Influence of anatomical location on CT numbers in cone beam computed tomography.
Oliveira, Matheus L; Tosoni, Guilherme M; Lindsey, David H; Mendoza, Kristopher; Tetradis, Sotirios; Mallya, Sanjay M
2013-04-01
To assess the influence of anatomical location on computed tomography (CT) numbers in mid- and full field of view (FOV) cone beam computed tomography (CBCT) scans. Polypropylene tubes with varying concentrations of dipotassium hydrogen phosphate (K₂HPO₄) solutions (50-1200 mg/mL) were imaged within the incisor, premolar, and molar dental sockets of a human skull phantom. CBCT scans were acquired using the NewTom 3G and NewTom 5G units. The CT numbers of the K₂HPO₄ phantoms were measured, and the relationship between CT numbers and K₂HPO₄ concentration was examined. The measured CT numbers of the K₂HPO₄ phantoms were compared between anatomical sites. At all six anatomical locations, there was a strong linear relationship between CT numbers and K₂HPO₄ concentration (R(2)>0.93). However, the absolute CT numbers varied considerably with the anatomical location. The relationship between CT numbers and object density is not uniform through the dental arch on CBCT scans. Copyright © 2013 Elsevier Inc. All rights reserved.
Pulmonary Artery Aneurysm/Pseudoaneurysm, a Delayed Complication of Lung Abscess: A Case Report.
Oguma, Tsuyoshi; Morise, Masahiro; Harada, Kazuki; Tanaka, Jun; Sato, Masako; Horio, Yukihiro; Takiguchi, Hiroto; Tomomatsu, Hiromi; Tomomatsu, Katsuyoshi; Takihara, Takahisa; Niimi, Kyoko; Hayama, Naoki; Aoki, Takuya; Urano, Tetsuya; Ito, Chihiro; Koizumi, Jun; Asano, Koichiro
2015-09-20
Massive hemoptysis mostly arises from the bronchial arteries; however, bleeding can also occur from a lesion in injured pulmonary arteries, such as pulmonary artery aneurysm/pseudoaneurysm (PAA/PAP), during pulmonary infection. A 66-year-old man was admitted with a diagnosis of lung abscess in the right lower lobe that was complicated with pyothorax. Intravenous administration of antibiotics and thoracic drainage successfully controlled the infection and inflammation until day 16, when the patient began to exhibit hemoptysis and bloody pleural effusion. Enhanced computed tomography (CT) with multi-planer reconstruction (MPR) images showed a highly enhanced mass inside the abscess fed by the pulmonary artery, suggesting PAA/PAP. Pulmonary angiography confirmed PAA/PAP, and embolization with coils successfully stopped both the bleeding into the sputum and pleural effusion, with a collapsed aneurysm visible on chest CT scan. Clinicians should consider the possibility of PAA/PAP in the differential diagnosis of hemoptysis during the treatment of patients with lung abscess. MPR CT is helpful for the diagnosis of PAA/PAP and its feeding vessels.
Blokhuis, Gijsbert J; Bleeker-Rovers, Chantal P; Diender, Marije G; Oyen, Wim J G; Draaisma, Jos M Th; de Geus-Oei, Lioe-Fee
2014-10-01
Fever of unknown origin (FUO) and unexplained fever during immune suppression in children are challenging medical problems. The aim of this study is to investigate the diagnostic value of fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and FDG-PET combined with computed tomography (FDG-PET/CT) in children with FUO and in children with unexplained fever during immune suppression. All FDG-PET/(CT) scans performed in the Radboud university medical center for the evaluation of FUO or unexplained fever during immune suppression in the last 10 years were reviewed. Results were compared with the final clinical diagnosis. FDG-PET/(CT) scans were performed in 31 children with FUO. A final diagnosis was established in 16 cases (52 %). Of the total number of scans, 32 % were clinically helpful. The sensitivity and specificity of FDG-PET/CT in these patients was 80 % and 78 %, respectively. FDG-PET/(CT) scans were performed in 12 children with unexplained fever during immune suppression. A final diagnosis was established in nine patients (75 %). Of the total number of these scans, 58 % were clinically helpful. The sensitivity and specificity of FDG-PET/CT in children with unexplained fever during immune suppression was 78 % and 67 %, respectively. FDG-PET/CT appears a valuable imaging technique in the evaluation of children with FUO and in the diagnostic process of children with unexplained fever during immune suppression. Prospective studies of FDG-PET/CT as part of a structured diagnostic protocol are warranted to assess the additional diagnostic value.
Koo, Henry; Leveridge, Mike; Thompson, Charles; Zdero, Rad; Bhandari, Mohit; Kreder, Hans J; Stephen, David; McKee, Michael D; Schemitsch, Emil H
2008-07-01
The purpose of this study was to measure interobserver reliability of 2 classification systems of pelvic ring fractures and to determine whether computed tomography (CT) improves reliability. The reliability of several radiographic findings was also tested. Thirty patients taken from a database at a Level I trauma facility were reviewed. For each patient, 3 radiographs (AP pelvis, inlet, and outlet) and CT scans were available. Six different reviewers (pelvic and acetabular specialist, orthopaedic traumatologist, or orthopaedic trainee) classified the injury according to Young-Burgess and Tile classification systems after reviewing plain radiographs and then after CT scans. The Kappa coefficient was used to determine interobserver reliability of these classification systems before and after CT scan. For plain radiographs, overall Kappa values for the Young-Burgess and Tile classification systems were 0.72 and 0.30, respectively. For CT scan and plain radiographs, the overall Kappa values for the Young-Burgess and Tile classification systems were 0.63 and 0.33, respectively. The pelvis/acetabular surgeons demonstrated the highest level of agreement using both classification systems. For individual questions, the addition of CT did significantly improve reviewer interpretation of fracture stability. The pre-CT and post-CT Kappa values for fracture stability were 0.59 and 0.93, respectively. The CT scan can improve the reliability of assessment of pelvic stability because of its ability to identify anatomical features of injury. The Young-Burgess system may be optimal for the learning surgeon. The Tile classification system is more beneficial for specialists in pelvic and acetabular surgery.
Diagnostic and prognostic value of 18F-FDG PET/CT in recurrent germinal tumor carcinoma.
Alongi, Pierpaolo; Evangelista, Laura; Caobelli, Federico; Spallino, Marianna; Gianolli, Luigi; Midiri, Massimo; Picchio, Maria
2018-01-01
The aim of this bicentric retrospective study was to assess the diagnostic performance, the prognostic value, the incremental prognostic value and the impact on therapeutic management of 18 F-FDG PET/CT in patients with suspected recurrent germinal cell testicular carcinoma (GCT). From the databases of two centers including 31,500 18 F-FDG PET/CT oncological studies, 114 patients affected by GCT were evaluated in a retrospective study. All 114 patients underwent 18 F-FDG PET/CT for suspected recurrent disease. Diagnostic performance of visually interpreted 18 F-FDG PET/CT and potential impact on the treatment decision were assessed using histology (17 patients), other diagnostic imaging modalities (i.e., contrast enhanced CT in 89 patients and MRI in 15) and clinical follow-up (114 patients) as reference. Progression-free survival (PFS) and overall survival (OS) rates were computed by means of Kaplan-Meier survival analysis. The progression rate (Hazard Ratio-HR) was determined using univariate Cox regression analysis by considering various clinical variables. Recurrent GCT was confirmed in 47 of 52 patients with pathological 18 F-FDG PET/CT findings, by means of histology in 18 patients and by other diagnostic imaging modalities/follow-up in 29. Sensitivity, specificity, accuracy, positive and negative likelihood ratio (LR+ and LR-, respectively), pre-test Odds-ratio and post-test Odds-ratio of 18 FDG PET/CT were 86.8%, 90.2%, 88.4%, 8.85, 0.14, 0.85, 8.85, respectively. 18 F-FDG PET/CT impacted significantly on therapeutic management in 26/114 (23%) cases (from palliative to curative in 12 patients, from "wait and watch" to new chemotherapy in six patients and the "wait-and-watch" approach in eight patients with unremarkable findings). At 2 and 5-year follow-up, PFS was significantly longer in patients with a negative than a pathological 18 F-FDG PET/CT scan (98% and 95% vs 48% and 38%, respectively; p = 0.02). An unremarkable scan was associated also with a longer OS (98% after 2 years and 95% after 5 years, p = 0.02). At univariate Cox regression analysis, a pathological 18 F-FDG PET/CT scan was associated with an increased risk of disease progression (HR = 24.3, CI 95% 14.1-40.6; p = 0.03) and lower OS (HR = 17.3 CI 95% 4,9-77; p < 0.001). Its prognostic value was confirmed also if tested against advanced disease at diagnosis and rising Human Chorionic Gonadotropin Beta (HCGB) or Alpha-Fetoprotein (AFP) (HR = 7.3 for STAGE III-PET+, p = 0.03; HR = 14.3 elevated HCGB-PET+, p = 0.02; HR 10.7 elevated AFP-PET+, p = 0.01) At multivariate analysis, only a pathological 18 F-FDG PET/CT scan and advanced disease in terms of TNM staging were predictors of disease progression and OS. 18 F-FDG PET/CT showed incremental value over other variables both in predicting PFS (chi-square from 24 to 40, p < 0.001) and OS (chi-square from 32 to 38, p = 0.003). 18 F-FDG PET/CT has a very good diagnostic performance in patients with suspected recurrent GCT and has an important prognostic value in assessing the rate of PFS and OS. Furthermore, 18 F-FDG PET/CT impacted the therapeutic regimen in 23% of patients, thus providing a significant impact in the restaging process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Min, Jonghwan; Pua, Rizza; Cho, Seungryong, E-mail: scho@kaist.ac.kr
Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in amore » circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the proposed scanning method and image reconstruction algorithm can effectively estimate the scatter in cone-beam projections and produce tomographic images of nearly scatter-free quality. The authors believe that the proposed method would provide a fast and efficient CBCT scanning option to various applications particularly including head-and-neck scan.« less
Upchurch, Cameron P; Grijalva, Carlos G; Wunderink, Richard G; Williams, Derek J; Waterer, Grant W; Anderson, Evan J; Zhu, Yuwei; Hart, Eric M; Carroll, Frank; Bramley, Anna M; Jain, Seema; Edwards, Kathryn M; Self, Wesley H
2018-03-01
The clinical significance of pneumonia visualized on CT scan in the setting of a normal chest radiograph is uncertain. In a multicenter prospective surveillance study of adults hospitalized with community-acquired pneumonia (CAP), we compared the presenting clinical features, pathogens present, and outcomes of patients with pneumonia visualized on a CT scan but not on a concurrent chest radiograph (CT-only pneumonia) and those with pneumonia visualized on a chest radiograph. All patients underwent chest radiography; the decision to obtain CT imaging was determined by the treating clinicians. Chest radiographs and CT images were interpreted by study-dedicated thoracic radiologists blinded to the clinical data. The study population included 2,251 adults with CAP; 2,185 patients (97%) had pneumonia visualized on chest radiography, whereas 66 patients (3%) had pneumonia visualized on CT scan but not on concurrent chest radiography. Overall, these patients with CT-only pneumonia had a clinical profile similar to those with pneumonia visualized on chest radiography, including comorbidities, vital signs, hospital length of stay, prevalence of viral (30% vs 26%) and bacterial (12% vs 14%) pathogens, ICU admission (23% vs 21%), use of mechanical ventilation (6% vs 5%), septic shock (5% vs 4%), and inhospital mortality (0 vs 2%). Adults hospitalized with CAP who had radiological evidence of pneumonia on CT scan but not on concurrent chest radiograph had pathogens, disease severity, and outcomes similar to patients who had signs of pneumonia on chest radiography. These findings support using the same management principles for patients with CT-only pneumonia and those with pneumonia seen on chest radiography. Copyright © 2017 American College of Chest Physicians. All rights reserved.
NASA Astrophysics Data System (ADS)
Dabin, Jérémie; Mencarelli, Alessandra; McMillan, Dayton; Romanyukha, Anna; Struelens, Lara; Lee, Choonsik
2016-06-01
Many organ dose calculation tools for computed tomography (CT) scans rely on the assumptions: (1) organ doses estimated for one CT scanner can be converted into organ doses for another CT scanner using the ratio of the Computed Tomography Dose Index (CTDI) between two CT scanners; and (2) helical scans can be approximated as the summation of axial slices covering the same scan range. The current study aims to validate experimentally these two assumptions. We performed organ dose measurements in a 5 year-old physical anthropomorphic phantom for five different CT scanners from four manufacturers. Absorbed doses to 22 organs were measured using thermoluminescent dosimeters for head-to-torso scans. We then compared the measured organ doses with the values calculated from the National Cancer Institute dosimetry system for CT (NCICT) computer program, developed at the National Cancer Institute. Whereas the measured organ doses showed significant variability (coefficient of variation (CoV) up to 53% at 80 kV) across different scanner models, the CoV of organ doses normalised to CTDIvol substantially decreased (12% CoV on average at 80 kV). For most organs, the difference between measured and simulated organ doses was within ±20% except for the bone marrow, breasts and ovaries. The discrepancies were further explained by additional Monte Carlo calculations of organ doses using a voxel phantom developed from CT images of the physical phantom. The results demonstrate that organ doses calculated for one CT scanner can be used to assess organ doses from other CT scanners with 20% uncertainty (k = 1), for the scan settings considered in the study.
Majidi, Shahram; Rahim, Basit; Gilani, Sarwat I; Gilani, Waqas I; Adil, Malik M; Qureshi, Adnan I
2016-05-01
The evolution of intracerebral hematoma and perihematoma edema in the ultra-early period on computed tomographic (CT) scans in patients with intracerebral hemorrhage (ICH) is not well understood. We aimed to investigate hematoma and perihematoma changes in "neutral brain" models of ICH. One human and five goat cadaveric heads were used as "neutral brains" to provide physical properties of brain without any biological activity or new bleeding. ICH was induced by slow injection of 4 ml of fresh human blood into the right basal ganglia of the goat brains. Similarly, 20 ml of fresh blood was injected deep into the white matter of the human cadaver head in each hemisphere. Serial CT scans of the heads were obtained immediately after hematoma induction and then 1, 3, and 5 hours afterward. Analyze software (AnalyzeDirect, Overland Park, KS, USA) was used to measure hematoma and perihematoma hypodensity volumes in the baseline and follow-up CT scans. The initial hematoma volumes of 11.6 ml and 10.5 ml in the right and left hemispheres of the cadaver brains gradually decreased to 6.6 ml and 5.4 ml at 5 hours, showing 43% and 48% retraction of hematoma, respectively. The volume of the perihematoma hypodensity in the right and left hemisphere increased from 2.6 ml and 2.2 ml in the 1-hour follow-up CT scans to 4.9 ml and 4.4 ml in the 5-hour CT scan, respectively. Hematoma retraction was also observed in all five goat brains ICH models with the mean ICH volume decreasing from 1.49 ml at baseline scan to 1.01 ml at the 5-hour follow-up CT scan (29.6% hematoma retraction). Perihematoma hypodensity was visualized in 70% of ICH in goat brains, with an increasing mean hypodensity volume of 0.4 ml in the baseline CT scan to 0.8 ml in the 5-hour follow-up CT scan. Our study demonstrated that substantial hematoma retraction and perihematoma hypodensity occurs in ICH in the absence of any new bleeding or biological activity of surrounding brain. Such observations suggest that active bleeding is underestimated in patients with no or small hematoma expansion and our understanding of perihematoma hypodensity needs to be reconsidered. Copyright © 2015 by the American Society of Neuroimaging.
Socio-economic variation in CT scanning in Northern England, 1990-2002
2012-01-01
Background Socio-economic status is known to influence health throughout life. In childhood, studies have shown increased injury rates in more deprived settings. Socio-economic status may therefore be related to rates of certain medical procedures, such as computed tomography (CT) scans. This study aimed to assess socio-economic variation among young people having CT scans in Northern England between 1990 and 2002 inclusive. Methods Electronic data were obtained from Radiology Information Systems of all nine National Health Service hospital Trusts in the region. CT scan data, including sex, date of scan, age at scan, number and type of scans were assessed in relation to quintiles of Townsend deprivation scores, obtained from linkage of postcodes with census data, using χ2 tests and Spearman rank correlations. Results During the study period, 39,676 scans were recorded on 21,089 patients, with 38,007 scans and 19,485 patients (11344 male and 8132 female) linkable to Townsend scores. The overall distributions of both scans and patients by quintile of Townsend deprivation scores were significantly different to the distributions of Townsend scores from the census wards included in the study (p < 0.0001). There was a significant association between type of scan and deprivation quintile (p < 0.0001), primarily due to the higher proportions of head scans in the three most deprived quintiles, and slightly higher proportions of chest scans and abdomen and pelvis scans in the least deprived groups. There was also a significant association (p < 0.0001) between the patient's age at the time of the CT scan and Townsend deprivation quintiles, with slightly increasing proportions of younger children with increasing deprivation. A similar association with age (p < 0.0001) was seen when restricting the data to include only the first scan of each patient. The number of scans per patient was also associated with Townsend deprivation quintiles (p = 0.014). Conclusions Social inequalities exist in the numbers of young people undergoing CT scans with those from deprived areas more likely to do so. This may reflect the rates of injuries in these individuals and implies that certain groups within the population may receive higher radiation doses than others due to medical procedures. PMID:22283843
Dynamic CT for Parathyroid Adenoma Detection: How Does Radiation Dose Compare With Nuclear Medicine?
Czarnecki, Caroline A; Einsiedel, Paul F; Phal, Pramit M; Miller, Julie A; Lichtenstein, Meir; Stella, Damien L
2018-05-01
Dynamic CT is increasingly used for preoperative localization of parathyroid adenomas, but concerns remain about the radiation effective dose of CT compared with that of 99m Tc-sestamibi scintigraphy. The purpose of this study was to compare the radiation dose delivered by three-phase dynamic CT with that delivered by 99m Tc-sestamibi SPECT/CT performed in accordance with our current protocols and to assess the possible reduction in effective dose achieved by decreasing the scan length (i.e., z-axis) of two phases of the dynamic CT protocol. The effective dose of a 99m Tc-sestamibi nuclear medicine parathyroid study performed with and without coregistration CT was calculated and compared with the effective dose of our current three-phase dynamic CT protocol as well as a proposed protocol involving CT with reduced scan length. The median effective dose for a 99m Tc-sestamibi nuclear medicine study was 5.6 mSv. This increased to 12.4 mSv with the addition of coregistration CT, which is higher than the median effective dose of 9.3 mSv associated with the dynamic CT protocol. Reducing the scan length of two phases in the dynamic CT protocol could reduce the median effective dose to 6.1 mSv, which would be similar to that of the dose from the 99m Tc-sestamibi study alone. Dynamic CT used for the detection of parathyroid adenoma can deliver a lower radiation dose than 99m Tc-sestamibi SPECT/CT. It may be possible to reduce the dose further by decreasing the scan length of two of the phases, although whether this has an impact on accuracy of the localization needs further investigation.
Three-Dimensions Segmentation of Pulmonary Vascular Trees for Low Dose CT Scans
NASA Astrophysics Data System (ADS)
Lai, Jun; Huang, Ying; Wang, Ying; Wang, Jun
2016-12-01
Due to the low contrast and the partial volume effects, providing an accurate and in vivo analysis for pulmonary vascular trees from low dose CT scans is a challenging task. This paper proposes an automatic integration segmentation approach for the vascular trees in low dose CT scans. It consists of the following steps: firstly, lung volumes are acquired by the knowledge based method from the CT scans, and then the data are smoothed by the 3D Gaussian filter; secondly, two or three seeds are gotten by the adaptive 2D segmentation and the maximum area selecting from different position scans; thirdly, each seed as the start voxel is inputted for a quick multi-seeds 3D region growing to get vascular trees; finally, the trees are refined by the smooth filter. Through skeleton analyzing for the vascular trees, the results show that the proposed method can provide much better and lower level vascular branches.
Spine oncology: Daedalus, Theseus, and the Minotaur.
Donthineni, Rakesh; Ofluoglu, Onder
2009-01-01
Over the past three decades, progress has been dramatic in the management of spine tumors. For example, advanced imaging technologies made available at manageable costs have lowered the threshold for scanning. CT, MRI, and PET imaging modalities have greatly enhanced the ability of the surgeon to accurately delineate the extension of the lesion within the bone, the soft tissue, and the spinal canal. Such enhancements have led to great leaps forward in preoperative planning and postoperative evaluation, including improved reconstruction options are resulting in improved outcomes. This article introduces the theme of this volume.
NASA Astrophysics Data System (ADS)
Takahashi, Noriyuki; Kinoshita, Toshibumi; Ohmura, Tomomi; Matsuyama, Eri; Toyoshima, Hideto
2018-02-01
The rapid increase in the incidence of Alzheimer's disease (AD) has become a critical issue in low and middle income countries. In general, MR imaging has become sufficiently suitable in clinical situations, while CT scan might be uncommonly used in the diagnosis of AD due to its low contrast between brain tissues. However, in those countries, CT scan, which is less costly and readily available, will be desired to become useful for the diagnosis of AD. For CT scan, the enlargement of the temporal horn of the lateral ventricle (THLV) is one of few findings for the diagnosis of AD. In this paper, we present an automated volumetry of THLV with segmentation based on Bayes' rule on CT images. In our method, first, all CT data sets are normalized into an atlas by using linear affine transformation and non-linear wrapping techniques. Next, a probability map of THLV is constructed in the normalized data. Then, THLV regions are extracted based on Bayes' rule. Finally, the volume of the THLV is evaluated. This scheme was applied to CT scans from 20 AD patients and 20 controls to evaluate the performance of the method for detecting AD. The estimated THLV volume was markedly increased in the AD group compared with the controls (P < .0001), and the area under the receiver operating characteristic curve (AUC) was 0.921. Therefore, this computerized method may have the potential to accurately detect AD on CT images.
CT radiation profile width measurement using CR imaging plate raw data
Yang, Chang‐Ying Joseph
2015-01-01
This technical note demonstrates computed tomography (CT) radiation profile measurement using computed radiography (CR) imaging plate raw data showing it is possible to perform the CT collimation width measurement using a single scan without saturating the imaging plate. Previously described methods require careful adjustments to the CR reader settings in order to avoid signal clipping in the CR processed image. CT radiation profile measurements were taken as part of routine quality control on 14 CT scanners from four vendors. CR cassettes were placed on the CT scanner bed, raised to isocenter, and leveled. Axial scans were taken at all available collimations, advancing the cassette for each scan. The CR plates were processed and raw CR data were analyzed using MATLAB scripts to measure collimation widths. The raw data approach was compared with previously established methodology. The quality control analysis scripts are released as open source using creative commons licensing. A log‐linear relationship was found between raw pixel value and air kerma, and raw data collimation width measurements were in agreement with CR‐processed, bit‐reduced data, using previously described methodology. The raw data approach, with intrinsically wider dynamic range, allows improved measurement flexibility and precision. As a result, we demonstrate a methodology for CT collimation width measurements using a single CT scan and without the need for CR scanning parameter adjustments which is more convenient for routine quality control work. PACS numbers: 87.57.Q‐, 87.59.bd, 87.57.uq PMID:26699559
SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X; Yang, K; Liu, B
Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length wasmore » used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.« less
Fachinger, Patrick; Tini, Gabrielo Mauro; Grobholz, Rainer; Gambazzi, Franco; Fankhauser, Hans; Irani, Sarosh
2015-03-26
Pulmonary tularaemia is a very rare disease with only a small number of cases described in the literature. So far, to our knowledge, there exists no case report of pulmonary tularaemia where PET-CT scans and follow up CT scans are available. We present four consecutive cases of pulmonary tularaemia. All patients suffered from non-specific symptoms. All patients were referred to our institution with strong suspicions of malignancy, particularly lung cancer. Diagnosis of tularaemia was made by typical findings in the aspirate of EBUS guided fine needle aspiration (necrosis, epithelioid cell aggregation) and surgical biopsy respectively, and a positive serology. In three of the four cases, the diagnosis was confirmed by positive PCR results of the tissue. PET-CT scans obtained in all four cases were indistinguishable from lesions typically seen in patients suffering from lung cancer. One of the four patients suffered from recurrence of the disease after antibiotic treatment; also this patient finally recovered after initiation of a second antibiotic regimen. One case became asymptomatic spontaneously, but this patient still received an antibiotic treatment. In one case, a follow up CT scan was unchanged compared to the initial PET-CT scan; in all other cases, the lesions disappeared almost completely. Symptoms of patients suffering from pulmonary tularaemia are non-specific and can be of prolonged character. PET-CT scans in these cases are indistinguishable from lung cancer. The diagnosis can be established when typical findings in EBUS guided fine needle aspirates or surgical biopsies are found in combination with a positive serology. In most cases the lesions disappear in follow up CT scans after clinically successful treatment.
TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Chan, F; Newman, B
2014-06-15
Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze themore » scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.« less
Pries-Heje, Mia M; Hasselbalch, Rasmus B; Raaschou, Henriette; Rezanavaz-Gheshlagh, Bijan; Heebøll, Hanne; Rehman, Shazia; Kristensen, Mariana; Andersen, Erik Henning; Ravn, Lisbet; Nèmery, Michel C; Lind, Morten N; Boel, Thomas; Ulriksen, Peter Sommer; Iversen, Kasper K
2018-02-17
Several large trials have evaluated the effect of CT screening based on specific symptoms, with varying outcomes. Screening of patients with CT based on their prognosis alone has not been examined before. For moderate-to-high risk patients presenting in the emergency department (ED), the potential gain from a CT scan might outweigh the risk of radiation exposure. We hypothesized that an accelerated "multiple rule out" CT screening of moderate-to-high risk patients will detect many clinically unrecognized diagnoses that affect change in treatment. Patients ≥ 40 years, triaged as high-risk or moderate-to-high risk according to vital signs, were eligible for inclusion. Patients were scanned with a combined ECG-gated and dual energy CT scan of cerebrum, thorax, and abdomen. The impact of the CT scan on patient diagnosis and treatment was examined prospectively by an expert panel. A total of 100 patients were included in the study, (53% female, mean age 73 years [age range, 43-93]). The scan lead to change in treatment or additional examinations in 37 (37%) patients, of which 24 (24%) were diagnostically significant, change in acute treatment in 11 (11%) cases and previously unrecognized malignant tumors in 10 (10%) cases. The mean size specific radiation dose was 15.9 mSv (± 3.1 mSv). Screening with a multi-rule out CT scan of high-risk patients in an ED is feasible and result in discovery of clinically unrecognized diagnoses and malignant tumors, but at the cost of radiation exposure and downstream examinations. The clinical impact of these findings should be evaluated in a larger randomized cohort.
Staging and follow-up of lacrimal gland carcinomas by 18F-FDG PET/CT imaging.
Tafti, Bashir Akhavan; Shaba, Wisam; Li, Yuxin; Yevdayev, Ella; Berenji, Gholam Reza
2012-10-01
A 74-year-old man with right eye proptosis, diplopia, and orbital discomfort for 3 to 4 months underwent biopsy, the specimen of which showed transitional cell carcinoma of the lacrimal gland. 18F-FDG PET/CT was also performed for staging purposes. Six months after orbital exenteration, a follow-up CT scan demonstrated soft tissue thickening along the nasal bridge but could not differentiate between postsurgical changes and cancer recurrence. A concurrent PET/CT scan did not show any evidence of abnormal metabolic activity, further emphasizing the higher accuracy of PET/CT in staging and restaging of head and neck cancers. An annual follow-up scan was still negative for active disease.
Fan-beam scanning laser optical computed tomography for large volume dosimetry
NASA Astrophysics Data System (ADS)
Dekker, K. H.; Battista, J. J.; Jordan, K. J.
2017-05-01
A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations.
Quantifying Three-Dimensional Morphology and RNA from Individual Embryos
Green, Rebecca M.; Leach, Courtney L.; Hoehn, Natasha; Marcucio, Ralph S.; Hallgrímsson, Benedikt
2017-01-01
Quantitative analysis of morphogenesis aids our understanding of developmental processes by providing a method to link changes in shape with cellular and molecular processes. Over the last decade many methods have been developed for 3D imaging of embryos using microCT scanning to quantify the shape of embryos during development. These methods generally involve a powerful, cross-linking fixative such as paraformaldehyde to limit shrinkage during the CT scan. However, the extended time frames that these embryos are incubated in such fixatives prevent use of the tissues for molecular analysis after microCT scanning. This is a significant problem because it limits the ability to correlate variation in molecular data with morphology at the level of individual embryos. Here, we outline a novel method that allows RNA, DNA or protein isolation following CT scan while also allowing imaging of different tissue layers within the developing embryo. We show shape differences early in craniofacial development (E11.5) between common mouse genetic backgrounds, and demonstrate that we are able to generate RNA from these embryos after CT scanning that is suitable for downstream RT-PCR and RNAseq analyses. PMID:28152580
Minor head injury in children.
Klig, Jean E; Kaplan, Carl P
2010-06-01
This review will examine mild closed head injury (CHI) and the current evidence on head computed tomography (CT) imaging risks in children, prediction rules to guide decisions on CT scan use, and issues of concussion after initial evaluation. The current literature offers preliminary evidence on the risks of radiation exposure from CT scans in children. A recent study introduces a validated prediction rule for use in mild CHI, to limit the number of CT scans performed. Concurrent with this progress, fast (or short sequence) MRI represents an emerging technology that may prove to be a viable alternative to CT scan use in certain cases of mild CHI where imaging is desired. The initial emergency department evaluation for mild CHI is the start point for a sequence of follow-up to assure that postconcussive symptoms fully resolve. The literature on sports-related concussion offers some information that may be used for patients with non-sports-related concussion. It is clear that CT scan use should be as safe and limited in scope as possible for children. Common decisions on the use of CT imaging for mild head injury can now be guided by a prediction rule for clinically important traumatic brain injury. Parameters for the follow-up care of patients with mild CHI after emergency department discharge are needed in the future to assure that postconcussive symptoms are adequately screened for full resolution.
Multi-energy spectral CT: adding value in emergency body imaging.
Punjabi, Gopal V
2018-04-01
Most vendors offer scanners capable of dual- or multi-energy computed tomography (CT) imaging. Advantages of multi-energy CT scanning include superior tissue characterization, detection of subtle iodine uptake differences, and opportunities to reduce contrast dose. However, utilization of this technology in the emergency department (ED) remains low. The purpose of this pictorial essay is to illustrate the value of multi-energy CT scanning in emergency body imaging.
The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, Daniel J.; Lee, Choonsik; Tien, Christopher
2013-01-15
Purpose: To validate the accuracy of a Monte Carlo source model of the Siemens SOMATOM Sensation 16 CT scanner using organ doses measured in physical anthropomorphic phantoms. Methods: The x-ray output of the Siemens SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code, MCNPX version 2.6. The resulting source model was able to perform various simulated axial and helical computed tomographic (CT) scans of varying scan parameters, including beam energy, filtration, pitch, and beam collimation. Two custom-built anthropomorphic phantoms were used to take dose measurements on the CT scanner: an adult male and amore » 9-month-old. The adult male is a physical replica of University of Florida reference adult male hybrid computational phantom, while the 9-month-old is a replica of University of Florida Series B 9-month-old voxel computational phantom. Each phantom underwent a series of axial and helical CT scans, during which organ doses were measured using fiber-optic coupled plastic scintillator dosimeters developed at University of Florida. The physical setup was reproduced and simulated in MCNPX using the CT source model and the computational phantoms upon which the anthropomorphic phantoms were constructed. Average organ doses were then calculated based upon these MCNPX results. Results: For all CT scans, good agreement was seen between measured and simulated organ doses. For the adult male, the percent differences were within 16% for axial scans, and within 18% for helical scans. For the 9-month-old, the percent differences were all within 15% for both the axial and helical scans. These results are comparable to previously published validation studies using GE scanners and commercially available anthropomorphic phantoms. Conclusions: Overall results of this study show that the Monte Carlo source model can be used to accurately and reliably calculate organ doses for patients undergoing a variety of axial or helical CT examinations on the Siemens SOMATOM Sensation 16 scanner.« less
Meintjes, Marguerite; Endozo, Raymond; Dickson, John; Erlandsson, Kjel; Hussain, Khalid; Townsend, Caroline; Menezes, Leon; Bomanji, Jamshed
2013-06-01
Congenital hyperinsulinism (CHI) is the most common cause of persistent hypoglycaemia in infants and children. Histologically, there are two subgroups, diffuse and focal. The aim of this study was to evaluate the accuracy of (18)F-fluoro-L-dihydroxyphenylalanine ((18)F-DOPA) PET/computed tomography (CT) and contrast-enhanced CT in distinguishing between focal and diffuse lesions in infants with CHI who are unresponsive to medical therapy. In addition, this paper describes the detailed protocol used for imaging and analysis of (18)F-DOPA PET/CT images in our clinical practice. Twenty-two (18)F-DOPA PET/CT and contrast-enhanced CT imaging studies were carried out on 18 consecutive patients (nine boys and nine girls) with CHI (median age, 2 years and 1 month; range, 1-84 months) who had positive dominant ABCC8 mutation genetic results or negative ABCC8/t results but did not respond to first-line medical therapy with high-dose diazoxide. (18)F-DOPA was produced by the cyclotron unit of Woolfson Molecular Imaging Centre, Manchester, and transported to our centre in central London after synthesis and implementation of quality control measures. (18)F-DOPA was administered intravenously at a dose of 4 MBq/kg, and iodine contrast medium was injected intravenously at a dose of 1.5 ml/kg. Single bed position PET/CT images of the pancreas were acquired under light sedation with oral chloral hydrate. Four PET dynamic data acquisition scans were taken 20, 40, 50 and 60 min after injection for a duration of 10 min each. The results were assessed by visual interpretation and quantitative measurements of standardized uptake values (SUVs) in the head, body, and tail of the pancreas. Of the 18 patients, 13 showed diffuse and five showed focal (18)F-DOPA PET pancreatic uptake. Three regions of interest were drawn over the head, body and tail of the pancreas to calculate the SUV(max). Using the formula - highest SUV(max)/next highest SUV(max) - a ratio was calculated. Five patients had an accumulation of F-DOPA in the pancreas and an SUV ratio greater than 1.5, indicating focal disease with an SUV(max) more than 50% higher than that of the unaffected areas of the pancreas. The remaining 13 patients had diffuse accumulation of (18)F-DOPA in the pancreas (SUV ratio<1.3). Using this ratio, a focal lesion can be distinguished from diffuse uptake and normal pancreatic uptake. The sizes of these regions of interest varied according to the age of the child. All patients diagnosed with focal lesions underwent surgery and were cured eventually. Lesions were accurately localized by PET/CT and confirmed by histological results after surgery. Three of these patients had to undergo second (18)F-DOPA scans and second surgeries after unsuccessful excision during their first surgery. Three patients with diffuse disease underwent a partial pancreatectomy, and histological results confirmed diffuse disease. One patient was cured and two remain on high-dose diazoxide therapy because of persistent hypoglycaemia. (18)F-DOPA PET/CT offers excellent differentiation of focal from diffuse CHI, and the contrast-enhanced CT technique permits precise preoperative localization of the lesion and anatomical landmarks.
Graziani, Tiziano; Ceci, Francesco; Castellucci, Paolo; Polverari, Giulia; Lima, Giacomo Maria; Lodi, Filippo; Morganti, Alessio Giuseppe; Ardizzoni, Andrea; Schiavina, Riccardo; Fanti, Stefano
2016-10-01
To evaluate (11)C-choline PET/CT as a diagnostic tool for restaging prostate cancer (PCa), in a large, homogeneous and clinically relevant population of patients with biochemical recurrence (BCR) of PCa after primary therapy. The secondary aim was to assess the best timing for performing (11)C-choline PET/CT during BCR. We retrospectively analysed 9,632 (11)C-choline PET/CT scans performed in our institution for restaging PCa from January 2007 to June 2015. The inclusion criteria were: (1) proven PCa radically treated with radical prostatectomy (RP) or with primary external beam radiotherapy (EBRT); (2) PSA serum values available; (3) proven BCR (PSA >0.2 ng/mL after RP or PSA >2 ng/mL above the nadir after primary EBRT with rising PSA levels). Finally, 3,203 patients with recurrent PCa matching all the inclusion criteria were retrospectively enrolled and 4,426 scans were analysed. Overall, 52.8 % of the (11)C-choline PET/CT scans (2,337/4,426) and 54.8 % of the patients (1,755/3,203) were positive. In 29.4 % of the scans, at least one distant finding was observed. The mean and median PSA values were, respectively, 4.9 and 2.1 ng/mL at the time of the scan (range 0.2 - 50 ng/mL). In our series, 995 scans were performed in patients with PSA levels between 1 and 2 ng/mL. In this subpopulation the positivity rate in the 995 scans was 44.7 %, with an incidence of distant findings of 19.2 % and an incidence of oligometastatic disease (one to three lesions) of 37.7 %. The absolute PSA value at the time of the scan and ongoing androgen deprivation therapy were associated with an increased probability of a positive (11)C-choline PET/CT scan (p < 0.0001). In the ROC analysis, a PSA value of 1.16 ng/mL was the optimal cut-off value. In patients with a PSA value <1.16 ng/mL, 26.8 % of 1,426 (11)C-choline PET/CT scans were positive, with oligometastatic disease in 84.7 % of positive scans. In a large cohort of patients, the feasibility of (11)C-choline PET/CT for detecting the sites of metastatic disease in PCa patients with BCR was confirmed. The PSA level was the main predictor of a positive scan with 1.16 ng/mL as the optimal cut-off value. In the majority of positive scans oligometastatic disease, potentially treatable with salvage therapies, was observed.
Ischemic stroke enhancement in computed tomography scans using a computational approach
NASA Astrophysics Data System (ADS)
Alves, Allan F. F.; Pavan, Ana L. M.; Jennane, Rachid; Miranda, José R. A.; Freitas, Carlos C. M.; Abdala, Nitamar; Pina, Diana R.
2018-03-01
In this work, a novel approach was proposed to enhance the visual perception of ischemic stroke in computed tomography scans. Through different image processing techniques, we enabled less experienced physicians, to reliably detect early signs of stroke. A set of 40 retrospective CT scans of patients were used, divided into two groups: 25 cases of acute ischemic stroke and 15 normal cases used as control group. All cases were obtained within 4 hours of symptoms onset. Our approach was based on the variational decomposition model and three different segmentation methods. A test determined observers' performance to correctly diagnose stroke cases. The Expectation Maximization method provided the best results among all observers. The overall sensitivity of the observer's analysis was 64% and increased to 79%. The overall specificity was 67% and increased to 78%. These results show the importance of a computational tool to assist neuroradiology decisions, especially in critical situations such as the diagnosis of ischemic stroke.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, B; He, W; Cvetkovic, D
Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with themore » CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
La Fontaine, M; Bradshaw, T; Kubicek, L
2014-06-15
Purpose: Regions of poor perfusion within tumors may be associated with higher hypoxic levels. This study aimed to test this hypothesis by comparing measurements of hypoxia from Cu-ATSM PET to vasculature kinetic parameters from DCE-CT kinetic analysis. Methods: Ten canine patients with sinonasal tumors received one Cu-ATSM PET/CT scan and three DCE-CT scans prior to treatment. Cu-ATSM PET/CT and DCE-CT scans were registered and resampled to matching voxel dimensions. Kinetic analysis was performed on DCE-CT scans and for each patient, the resulting kinetic parameter values from the three DCE-CT scans were averaged together. Cu-ATSM SUVs were spatially correlated (r{sub spatial})more » on a voxel-to-voxel basis against the following DCE-CT kinetic parameters: transit time (t{sub 1}), blood flow (F), vasculature fraction (v{sub 1}), and permeability (PS). In addition, whole-tumor comparisons were performed by correlating (r{sub ROI}) the mean Cu-ATSM SUV (SUV{sub mean}) with median kinetic parameter values. Results: The spatial correlations (r{sub spatial}) were poor and ranged from -0.04 to 0.21 for all kinetic parameters. These low spatial correlations may be due to high variability in the DCE-CT kinetic parameter voxel values between scans. In our hypothesis, t{sub 1} was expected to have a positive correlation, while F was expected to have a negative correlation to hypoxia. However, in wholetumor analysis the opposite was found for both t{sub 1} (r{sub ROI} = -0.25) and F (r{sub ROI} = 0.56). PS and v{sub 1} may depict angiogenic responses to hypoxia and found positive correlations to Cu-ATSM SUV for PS (r{sub ROI} = 0.41), and v{sub 1} (r{sub ROI} = 0.57). Conclusion: Low spatial correlations were found between Cu-ATSM uptake and DCE-CT vasculature parameters, implying that poor perfusion is not associated with higher hypoxic regions. Across patients, the most hypoxic tumors tended to have higher blood flow values, which is contrary to our initial hypothesis. Funding: R01 CA136927.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanchon, L; INSERM U1101, Brest; Apte, A
2015-06-15
Purpose: PET/CT guidance is used for biopsies of metabolically active lesions, which are not well seen on CT alone or to target the metabolically active tissue in tumor ablations. It has also been shown that PET/CT guided biopsies provide an opportunity to verify the location of the lesion border at the place of needle insertion. However the error in needle placement with respect to the metabolically active region may be affected by motion between the PET/CT scan performed at the start of the procedure and the CT scan performed with the needle in place and this error has not beenmore » previously quantified. Methods: Specimens from 31 PET/CT guided biopsies were investigated and correlated to the intraoperative PET scan under an IRB approved HIPAA compliant protocol. For 4 of the cases in which larger motion was suspected a second PET scan was obtained with the needle in place. The CT and the PET images obtained before and after the needle insertion were used to calculate the displacement of the voxels along the needle path. CTpost was registered to CTpre using a free form deformable registration and then fused with PETpre. The shifts between the PET image contours (42% of SUVmax) for PETpre and PETpost were obtained at the needle position. Results: For these extreme cases the displacement of the CT voxels along the needle path ranged from 2.9 to 8 mm with a mean of 5 mm. The shift of the PET image segmentation contours (42% of SUVmax) at the needle position ranged from 2.3 to 7 mm between the two scans. Conclusion: Evaluation of the mis-registration between the CT with the needle in place and the pre-biopsy PET can be obtained using deformable registration of the respective CT scans and can be used to indicate the need of a second PET in real-time. This work is supported in part by a grant from Biospace Lab, S.A.« less
FDG-PET/CT in autosomal dominant polycystic kidney disease patients with suspected cyst infection.
Pijl, Jordy Pieter; Glaudemans, Andor W J M; Slart, Riemer H J A; Kwee, Thomas Christian
2018-04-13
Purpose: To determine the value of 18 F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/computed tomography (CT) for diagnosing renal or hepatic cyst infection in patients with autosomal dominant polycystic kidney disease (ADPKD). Methods: This retrospective single-center study included all patients with ADPKD who underwent FDG-PET/CT because of suspected cyst infection between 2010 and 2017. Results: Thirty FDG-PET/CT scans of thirty individual patients were included, of which 19 were positive for cyst infection. According to a previously established clinical and biochemical reference standard, FDG-PET/CT achieved sensitivity of 88.9%, specificity of 75.0%, positive predictive value of 84.2%, and negative predictive value of 81.8% for the diagnosis of cyst infection. In 5 cases, FDG-PET/CT suggested a different pathologic process that explained the symptoms, including pneumonia ( n = 1), generalized peritonitis ( n = 1), pancreatitis ( n = 1), colitis ( n = 1), and cholangitis ( n = 1). Total duration of hospital stay and duration between FDG-PET/CT scan and hospital discharge of patients with an FDG-PET/CT scan positive for cyst infection were significantly longer than those with a negative scan ( P = 0.005 and P = 0.009, respectively). Creatinine levels were significantly higher in patients with an FDG-PET/CT scan positive for cyst infection than in patients with a negative scan ( P = 0.015). Other comparisons of clinical parameters (age, gender, presence of fever (>38.5°C) for more than 3 days, abdominal pain, history of solid organ transplantation and nephrectomy, immune status), laboratory values (C-reactive protein level (CRP), leukocyte count, estimated glomerular filtration rate), and microbiologic results (blood and urine cultures) were not significantly different ( P = 0.13-1.00) between FDG-PET/CT-positive and -negative patients. Conclusion: FDG-PET/CT is a useful and recommendable (upfront) imaging modality for the evaluation of patients with ADPKD and suspected cyst infection. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.