Hansen, Cristi V.; Whisnant, Joshua A.; Lanning-Rush, Jennifer L.
2014-01-01
There was a larger percentage storage-volume increase since 1993 in the central part of the study area than in either the basin storage area or the entire study area. Storage-volume in the central part of the study area during winter 2012, summer 2013, winter 2013, and winter 2014 recovered about 46,300 acre-feet or more compared to the storage volume in 1993. In summer 2012 and winter 2013, the storage-volume increase since 1993 was larger in the central part of the study area than in the entire study area, indicating the storage-volume increases in the central part of the study area offset decreases in storage volume in the rest of the study area. The larger increase in storage volume in the central part of the study area than in the rest of the study area probably was because of the Integrated Local Water Supply Program strategy that reduced city pumpage from the Equus Beds aquifer by about 40 percent. The current (winter 2014) storage volumes in the entire study area and the central part of the study area are about 94 and 96 percent of their respective predevelopment storage volumes or about 3,067,000 and 962,000 acre-feet, respectively.
THE ROLE OF VISUALS IN VERBAL LEARNING--STUDIES IN TELEVISED INSTRUCTION, REPORT 3, SUMMARY REPORT.
ERIC Educational Resources Information Center
GROPPER, GEORGE L.
THE INTEGRATION OF WORDS AND PICTURES IN THE TWO STUDIES REPORTED IN THIS VOLUME WAS ACCOMPLISHED UNCONVENTIONALLY. IN ONE STUDY, AN ENTIRE TOPIC, ARCHIMEDES' LAW, WAS COVERED IN A SELF-CONTAINED, ENTIRELY PICTORIAL LESSON AND ALSO IN A SELF-CONTAINED, ENTIRELY VERBAL LESSON. STUDENTS ACQUIRED ALL THE CONCEPTS AND PRINCIPLES MAKING UP ARCHIMEDES'…
Renewable Electricity Futures Study - Volume One
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hand, Maureen; Mai, Treui; Baldwin, Sam
Renewable Electricity Futures Study - Volume One. This is part of a series of four volumes describing exploring a high-penetration renewable electricity future for the United States of America. This data set is provides data for the entire volume one document and includes all data for the charts and graphs included in the document.
Volume, Conservation and Instruction: A Classroom Based Solomon Four Group Study of Conflict.
ERIC Educational Resources Information Center
Rowell, J. A.; Dawson, C. J.
1981-01-01
Summarizes a study to widen the applicability of Piagetian theory-based conflict methodology from individual situations to entire classes. A Solomon four group design was used to study effects of conflict instruction on students' (N=127) ability to conserve volume of noncompressible matter and to apply that knowledge to gas volume. (Author/JN)
Estimating aspen volume and weight for individual trees, diameter classes, or entire stands.
Bryce E. Schlaegel
1975-01-01
Presents allometric volume and weight equations for Minnesota quaking aspen. Volume, green weight, and dry weight estimates can be made for wood, bark, and limbs on the basis of individual trees, diameter classes, or entire stands.
DOT National Transportation Integrated Search
2001-06-01
Volume 1 is a summary report which chronicles the research highlights of the entire study of microdamage healing in asphalt concrete. The primary objectives of the study were to: (1) Demonstrate that microdamage healing occurs and that it can be meas...
NASA Technical Reports Server (NTRS)
Amar, Adam J.; Blackwell, Ben F.; Edwards, Jack R.
2007-01-01
The development and verification of a one-dimensional material thermal response code with ablation is presented. The implicit time integrator, control volume finite element spatial discretization, and Newton's method for nonlinear iteration on the entire system of residual equations have been implemented and verified for the thermochemical ablation of internally decomposing materials. This study is a continuation of the work presented in "One-Dimensional Ablation with Pyrolysis Gas Flow Using a Full Newton's Method and Finite Control Volume Procedure" (AIAA-2006-2910), which described the derivation, implementation, and verification of the constant density solid energy equation terms and boundary conditions. The present study extends the model to decomposing materials including decomposition kinetics, pyrolysis gas flow through the porous char layer, and a mixture (solid and gas) energy equation. Verification results are presented for the thermochemical ablation of a carbon-phenolic ablator which involves the solution of the entire system of governing equations.
Hörnig, Marie K.; Haug, Joachim T.; Noever, Christoph; Høeg, Jens T.; Glenner, Henrik
2017-01-01
Rhizocephala, a group of parasitic castrators of other crustaceans, shows remarkable morphological adaptations to their lifestyle. The adult female parasite consists of a body that can be differentiated into two distinct regions: a sac-like structure containing the reproductive organs (the externa), and a trophic, root like system situated inside the hosts body (the interna). Parasitism results in the castration of their hosts, achieved by absorbing the entire reproductive energy of the host. Thus, the ratio of the host and parasite sizes is crucial for the understanding of the parasite’s energetic cost. Using advanced imaging methods (micro-CT in conjunction with 3D modeling), we measured the volume of parasitic structures (externa, interna, egg mass, egg number, visceral mass) and the volume of the entire host. Our results show positive correlations between the volume of (1) entire rhizocephalan (externa + interna) and host body, (2) rhizocephalan externa and host body, (3) rhizocephalan visceral mass and rhizocephalan body, (4) egg mass and rhizocephalan externa, (5) rhizocephalan egg mass and their egg number. Comparing the rhizocephalan Sylon hippolytes, a parasite of caridean shrimps, and representatives of Peltogaster, parasites of hermit crabs, we could match their different traits on a reconstructed relationship. With this study we add new and significant information to our global understanding of the evolution of parasitic castrators, of interactions between a parasitic castrator and its host and of different parasitic strategies within parasitic castrators exemplified by rhizocephalans. PMID:28678878
DOT National Transportation Integrated Search
1981-03-01
This report (Volume 4 of four volumes) provides the scripts for all audiovisuals employed in the PEDSAFE Program. Volume 1 of this report describes the conduct and results of the evaluation of the entire PEDSAFE Program and provides recommendations c...
DOT National Transportation Integrated Search
1981-03-30
This report (Volume 2 of four volumes) serves as a users guide for elementary schools implementing the PEDSAFE Program. Volume 1 of this report describes the conduct and results of the evaluation of the entire PEDSAFE Program and provides recommendat...
Identification of wood energy resources in central Michigan
NASA Technical Reports Server (NTRS)
Hudson, W. D.; Kittleson, K.
1978-01-01
Existing biomass studies were compiled for determining their applicability in measuring forest biomass in an entirely new way. Over sixty tree-weight tables were prepared from existing tables or formulas. An estimate of forest biomass was made on a defined area by using Landsat Satellite data analysis, existing forest cover type maps and actual weighting of the entire biomass. Control plots were cruised for normal volume data and weight data, harvested and weighed to determine actual tonnage yields.
Method and apparatus for probing relative volume fractions
Jandrasits, Walter G.; Kikta, Thomas J.
1998-01-01
A relative volume fraction probe particularly for use in a multiphase fluid system includes two parallel conductive paths defining therebetween a sample zone within the system. A generating unit generates time varying electrical signals which are inserted into one of the two parallel conductive paths. A time domain reflectometer receives the time varying electrical signals returned by the second of the two parallel conductive paths and, responsive thereto, outputs a curve of impedance versus distance. An analysis unit then calculates the area under the curve, subtracts the calculated area from an area produced when the sample zone consists entirely of material of a first fluid phase, and divides this calculated difference by the difference between an area produced when the sample zone consists entirely of material of the first fluid phase and an area produced when the sample zone consists entirely of material of a second fluid phase. The result is the volume fraction.
Method and apparatus for probing relative volume fractions
Jandrasits, W.G.; Kikta, T.J.
1998-03-17
A relative volume fraction probe particularly for use in a multiphase fluid system includes two parallel conductive paths defining therebetween a sample zone within the system. A generating unit generates time varying electrical signals which are inserted into one of the two parallel conductive paths. A time domain reflectometer receives the time varying electrical signals returned by the second of the two parallel conductive paths and, responsive thereto, outputs a curve of impedance versus distance. An analysis unit then calculates the area under the curve, subtracts the calculated area from an area produced when the sample zone consists entirely of material of a first fluid phase, and divides this calculated difference by the difference between an area produced when the sample zone consists entirely of material of the first fluid phase and an area produced when the sample zone consists entirely of material of a second fluid phase. The result is the volume fraction. 9 figs.
DOT National Transportation Integrated Search
1981-03-30
This report (Volume 3 of four volumes) provides detailed descriptions of all printed program materials employed in the Junior/Senior High School PEDSAFE Program. Volume 1 of this report describes the conduct and sults of the evaluation of the entire ...
Revert Ventura, A J; Sanz Requena, R; Martí-Bonmatí, L; Pallardó, Y; Jornet, J; Gaspar, C
2014-01-01
To study whether the histograms of quantitative parameters of perfusion in MRI obtained from tumor volume and peritumor volume make it possible to grade astrocytomas in vivo. We included 61 patients with histological diagnoses of grade II, III, or IV astrocytomas who underwent T2*-weighted perfusion MRI after intravenous contrast agent injection. We manually selected the tumor volume and peritumor volume and quantified the following perfusion parameters on a voxel-by-voxel basis: blood volume (BV), blood flow (BF), mean transit time (TTM), transfer constant (K(trans)), washout coefficient, interstitial volume, and vascular volume. For each volume, we obtained the corresponding histogram with its mean, standard deviation, and kurtosis (using the standard deviation and kurtosis as measures of heterogeneity) and we compared the differences in each parameter between different grades of tumor. We also calculated the mean and standard deviation of the highest 10% of values. Finally, we performed a multiparametric discriminant analysis to improve the classification. For tumor volume, we found statistically significant differences among the three grades of tumor for the means and standard deviations of BV, BF, and K(trans), both for the entire distribution and for the highest 10% of values. For the peritumor volume, we found no significant differences for any parameters. The discriminant analysis improved the classification slightly. The quantification of the volume parameters of the entire region of the tumor with BV, BF, and K(trans) is useful for grading astrocytomas. The heterogeneity represented by the standard deviation of BF is the most reliable diagnostic parameter for distinguishing between low grade and high grade lesions. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
NASA Technical Reports Server (NTRS)
Mueller, J. L. (Editor); Fargion, Giuletta S. (Editor); McClain, Charles R. (Editor); Pegau, Scott; Zaneveld, J. Ronald V.; Mitchell, B. Gregg; Kahru, Mati; Wieland, John; Stramska, Malgorzat
2003-01-01
This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.
NASA Technical Reports Server (NTRS)
Mueller, J. L. (Editor); Fargion, Giulietta S. (Editor); McClain, Charles R. (Editor)
2003-01-01
This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.
Computed tomographic evaluation of abdominal fat in minipigs.
Chang, Jinhwa; Jung, Joohyun; Lee, Hyeyeon; Chang, Dongwoo; Yoon, Junghee; Choi, Mincheol
2011-03-01
Computed tomography (CT) exams were conducted to determine the distribution of abdominal fat identified based on the CT number measured in Hounsfield Units (HU) and to measure the volume of the abdominal visceral and subcutaneous fat in minipigs. The relationship between the CT-based fat volumes of several vertebral levels and the entire abdomen and anthropometric data including the sagittal abdominal diameter and waist circumference were evaluated. Moreover, the total fat volumes at the T11, T13, L3, and L5 levels were compared with the total fat volume of the entire abdomen to define the landmark of abdominal fat distribution. Using a single-detector CT, six 6-month-old male minipigs were scanned under general anesthesia. Three radiologists then assessed the HU value of visceral and subcutaneous abdominal fat by drawing the region of interest manually at the T11, T13, L1, L3, and L5 levels. The CT number and abdominal fat determined in this way by the three radiologists was found to be correlated (intra-class coefficient = 0.9). The overall HU ranges for the visceral and subcutaneous fat depots were -147.47 to -83.46 and -131.62 to -90.97, respectively. The total fat volume of the entire abdomen was highly correlated with the volume of abdominal fat at the T13 level (r = 0.97, p < 0.0001). These findings demonstrate that the volume of abdominal adipose tissue measured at the T13 level using CT is a strong and reliable predictor of total abdominal adipose volume.
NASA Astrophysics Data System (ADS)
Ali, Anwar; Ansari, Sana; Uzair, Sahar; Tasneem, Shadma; Nabi, Firdosa
2015-11-01
Densities ρ and ultrasonic speeds u for pure diethylene glycol, 1-butanol, 2-butanol, and 1,4-butanediol and for their binary mixtures over the entire composition range were measured at 298.15 K, 303.15 K, 308.15 K, and 313.15 K. Using these data, the excess molar volumes, VE_m, deviations in isentropic compressibilities, {\\varDelta }ks, apparent molar volumes, V_{φi} , partial molar volumes, overline{V}_{m,i} , and excess partial molar volumes, overline{V}_{m,i}^E , have been calculated over the entire composition range, and also the excess partial molar volumes of the components at infinite dilution, overline{V}_{m,i}^{E,infty } have been calculated. The excess functions have been correlated using the Redlich-Kister equation at different temperatures. The variations of these derived parameters with composition and temperature are presented graphically.
ERIC Educational Resources Information Center
Lee, Arthur M.
This is the first part of a two-part fifth volume in a series of annual reports on the status of vocational education in the United States. It primarily reports the developments that have taken place each year in the numbers and characteristics of students enrolled, programs, costs, and results. (The entire study, initiated by Congress in 1971, is…
NASA Technical Reports Server (NTRS)
Mueller, J. L.; Fargion, G. S.; McClain, C. R. (Editor); Pegau, S.; Zanefeld, J. R. V.; Mitchell, B. G.; Kahru, M.; Wieland, J.; Stramska, M.
2003-01-01
This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.
Zhang, Yujuan; Chen, Jun; Liu, Song; Shi, Hua; Guan, Wenxian; Ji, Changfeng; Guo, Tingting; Zheng, Huanhuan; Guan, Yue; Ge, Yun; He, Jian; Zhou, Zhengyang; Yang, Xiaofeng; Liu, Tian
2017-02-01
To investigate the efficacy of histogram analysis of the entire tumor volume in apparent diffusion coefficient (ADC) maps for differentiating between histological grades in gastric cancer. Seventy-eight patients with gastric cancer were enrolled in a retrospective 3.0T magnetic resonance imaging (MRI) study. ADC maps were obtained at two different b values (0 and 1000 sec/mm 2 ) for each patient. Tumors were delineated on each slice of the ADC maps, and a histogram for the entire tumor volume was subsequently generated. A series of histogram parameters (eg, skew and kurtosis) were calculated and correlated with the histological grade of the surgical specimen. The diagnostic performance of each parameter for distinguishing poorly from moderately well-differentiated gastric cancers was assessed by using the area under the receiver operating characteristic curve (AUC). There were significant differences in the 5 th , 10 th , 25 th , and 50 th percentiles, skew, and kurtosis between poorly and well-differentiated gastric cancers (P < 0.05). There were correlations between the degrees of differentiation and histogram parameters, including the 10 th percentile, skew, kurtosis, and max frequency; the correlation coefficients were 0.273, -0.361, -0.339, and -0.370, respectively. Among all the histogram parameters, the max frequency had the largest AUC value, which was 0.675. Histogram analysis of the ADC maps on the basis of the entire tumor volume can be useful in differentiating between histological grades for gastric cancer. 4 J. Magn. Reson. Imaging 2017;45:440-449. © 2016 International Society for Magnetic Resonance in Medicine.
Ghanayem, A J; Wilber, J H; Lieberman, J M; Motta, A O
1995-03-01
Determine if laparotomy further destabilizes an unstable pelvic injury and increases pelvic volume, and if reduction and stabilization restores pelvic volume and prevents volume changes secondary to laparotomy. Cadaveric pelvic fracture model. Unilateral open-book pelvic ring injuries were created in five fresh cadaveric specimens by directly disrupting the pubic symphysis, left sacroliac joint, and sacrospinous and sacrotuberous ligaments. Pelvic volume was determined using computerized axial tomography for the intact pelvis, disrupted pelvis with both a laparotomy incision opened and closed, and disrupted pelvis stabilized and reduced using an external fixator with the laparotomy incision opened. The average volume increase in the entire pelvis (from the top of the iliac crests to the bottom of the ischial tuberosities) between a nonstabilized injury with the abdomen closed and then subsequently opened was 15 +/- 5% (423 cc). The average increase in entire pelvic volume between a stabilized and reduced pelvis and nonstabilized pelvis, both with the abdomen open, was 26 +/- 5% (692 cc). The public diastasis increased from 3.9 to 9.3 cm in a nonstabilized pelvis with the abdomen closed and then subsequently opened. Application of a single-pin anterior-frame external fixator reduced the pubic diastasis anatomically and reduced the average entire and true (from the pelvic brim to the ischeal tuberosities) pelvic volumes to within 3 +/- 4 and 8 +/- 6% of the initial volume, respectively. We believe that the abdominal wall provides stability to an unstable pelvic ring injury via a tension band effect on the iliac wings. Our results demonstrate that a laparotomy further destabilized an open-book pelvic injury and subsequently increased pelvic volume and pubic diastasis. This could potentially increase blood loss from the pelvic injury and delay the tamponade effect of reduction and stabilization. A single-pin external fixator prevents the destabilizing effect of the laparotomy and effectively reduces pelvic volume. These data support reduction and temporary stabilization of unstable pelvic injuries before or concomitantly with laparotomy.
Studies in Environment--Volume IV: Consumption Differentials and the Environment.
ERIC Educational Resources Information Center
Olsen, Mary Beth; And Others
In this study, a mathematical model is used to tie both direct and indirect industrial pollution generated by fluctuations of the entire economy to behavioral patterns of the consuming public. The model studies consumer behavior patterns from three viewpoints: income of family, age of head of family, and regional location of family within the…
Kecik, Dariusz; Makowiec-Tabernacka, Marta; Golebiewska, Joanna; Moneta-Wielgos, Joanna; Kasprzak, Jan
2009-01-01
To evaluate changes in the macular thickness and volume using optical coherence tomography in patients after phacoemulsification and intracapsular implantation of a foldable intraocular lens. The study included 82 patients (37 males and 45 females) after phacoemulsification and intracapsular implantaion of the same type of a foldable intraocular lens, without any other eye disease. Phacoemulsification was performed with an INFINITI machine. In all patients, macular thickness and volume were measured with an optical coherence tomograph (Stratus OCT) using the Fast Macular Thickness Map. The OCT evaluation was performed on days 1, 7, 30 and 90 postoperatively. In 58 patients (71%), it was additionally performed at 12 months after surgery and in 52 patients (63%) the macular parameters in the healthy and operated eyes were compared. A statistically significant increase in the minimal retinal thickness was observed on days 30 (p<0.0005) and 90 (p<0.005) postoperatively compared to post-operative day 1. A statistically significant increase in the foveal volume was seen on days 30 (p<0.00005) and 90 (p<0.0005). A statistically significant increase in the volume of the entire macula was found on days 7, 30 and 90 (p<0.00005). Uncomplicated cataract phacoemulsification is followed by increases in the central retinal thickness, foveal volume and volume of the entire macula on days 30 and 90 and at 12 months postoperatively. Further observation of patients is required to confirm whether the macular parameters will return to their values on day 1 postoperatively and if so, when this will occur.
Zhang, Qun; Lin, Shi-Rong; He, Fang; Kang, De-Hua; Chen, Guo-Zhang; Luo, Wei
2011-11-01
Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volumes and normal tissues in postoperative intensity-modulated radiotherapy (IMRT) after placing a water-filled balloon into the resection cavity. Three postoperative patients with advanced maxillary sinus carcinoma were selected in this trial. Water-filled balloons and supporting dental stents were fabricated according to the size of the maxillary resection cavity. Simulation CT scans were performed with or without water-filled balloons, IMRT treatment plans were established, and dose distribution to target volumes and organs at risk were evaluated. Compared to those in the treatment plan without balloons, the dose (D98) delivered to 98% of the gross tumor volume (GTV) increased by 2.1 Gy (P = 0.009), homogeneity index (HI) improved by 2.3% (P = 0.001), and target volume conformity index (TCI) of 68 Gy increased by 18.5% (P = 0.011) in the plan with balloons. Dosimetry endpoints of normal tissues around target regions in both plans were not significantly different (P > 0.05) except for the optic chiasm. In the plan without balloons, 68 Gy high-dose regions did not entirely cover target volumes in the ethmoid sinus, posteromedial wall of the maxillary sinus, or surgical margin of the hard palate. In contrast, 68 Gy high-dose regions entirely covered the GTV in the plan with balloons. These results suggest that placing a water-filled balloon in the resection cavity for postoperative IMRT of maxillary sinus carcinoma can reduce low-dose regions and markedly and simultaneously increase dose homogeneity and conformity of target volumes.
A global CT to US registration of the lumbar spine
NASA Astrophysics Data System (ADS)
Nagpal, Simrin; Hacihaliloglu, Ilker; Ungi, Tamas; Rasoulian, Abtin; Osborn, Jill; Lessoway, Victoria A.; Rohling, Robert N.; Borschneck, Daniel P.; Abolmaesumi, Purang; Mousavi, Parvin
2014-03-01
During percutaneous lumbar spine needle interventions, alignment of the preoperative computed tomography (CT) with intraoperative ultrasound (US) can augment anatomical visualization for the clinician. We propose an approach to rigidly align CT and US data of the lumbar spine. The approach involves an intensity-based volume registration step, followed by a surface segmentation and a point-based registration of the entire lumbar spine volume. A clinical feasibility study resulted in mean registration error of approximately 3 mm between CT and US data.
Post-traumatic changes in, and effect of colloid osmotic pressure on the distribution of body water.
Böck, J C; Barker, B C; Clinton, A G; Wilson, M B; Lewis, F R
1989-09-01
The aim of this study was to define the post-traumatic changes in body fluid compartments and to evaluate the effect of plasma colloid osmotic pressure (COP) on the partitioning of body fluid between these compartments. Forty-two measurements of plasma volume (green dye), extracellular volume (bromine), and total body water (deuterium) were done in ten traumatized patients (mean Injury Severity Score, ISS, = 34) and 23 similar control studies were done in eight healthy volunteers who were in stable fluid balance. Interstitial volume, intracellular volume, and blood volume were calculated from measured fluid spaces and hematocrit; COP was directly measured. Studies in volunteers on consecutive days indicated good reproducibility, with coefficients of variation equal to 3.5% for COP, 6.3% for plasma volume, 4.5% for extracellular volume, and 4.9% for total body water. COP values extended over the entire range seen clinically, from 10 to 30 mmHg. Interstitial volume was increased by 55% in patients, but intracellular volume was decreased by 10%. We conclude (1) that posttraumatic peripheral edema resulting from hemodilution is located in the interstitial compartment, with no intracellular space expansion; and (2) that interstitial volume, but not intracellular volume, is closely related to plasma COP.
NASA Technical Reports Server (NTRS)
Serafini, T. T.; Vanucci, R. D.; Cavano, P. J.; Winters, W. E.
1980-01-01
Components made of composite materials are heated in autoclaves by employing electrical resistance heating blankets, thus avoiding need to heat entire autoclave volume. Method provides not only significant energy savings compared to heating entire pressure vessel but offers time savings in accelerated heat-up and cool-down cycles.
40 CFR 1037.150 - Interim provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... earlier model years for electric vehicles) to the greenhouse gas standards of this part. (1) This... for any vehicles other than electric vehicles, you must certify your entire U.S.-directed production... electric vehicles, you must certify your entire U.S.-directed production volume within the regulatory sub...
40 CFR 1037.150 - Interim provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... earlier model years for electric vehicles) to the greenhouse gas standards of this part. (1) This... for any vehicles other than electric vehicles, you must certify your entire U.S.-directed production... electric vehicles, you must certify your entire U.S.-directed production volume within the regulatory sub...
JOSE, Jupiter orbiting spacecraft: A systems study, volume 1
NASA Technical Reports Server (NTRS)
1971-01-01
A brief summary of the mechanical properties of Jupiter is presented along with an organizational outline of the entire JOSE program. Other aspects of the program described include: spacecraft design, mission trajectories, altitude control, propulsion subsystem, on-board power supply, spacecraft structures and environmental design considerations, and telemetry.
Mazonakis, Michalis; Sahin, Bunyamin; Pagonidis, Konstantin; Damilakis, John
2011-06-01
The aim of this study was to combine the stereological technique with magnetic resonance (MR) imaging data for the volumetric and functional analysis of the left ventricle (LV). Cardiac MR examinations were performed in 13 consecutive subjects with known or suspected coronary artery disease. The end-diastolic volume (EDV), end-systolic volume, ejection fraction (EF), and mass were estimated by stereology using the entire slice set depicting LV and systematic sampling intensities of 1/2 and 1/3 that provided samples with every second and third slice, respectively. The repeatability of stereology was evaluated. Stereological assessments were compared with the reference values derived by manually tracing the endocardial and epicardial contours on MR images. Stereological EDV and EF estimations obtained by the 1/3 systematic sampling scheme were significantly different from those by manual delineation (P < .05). No difference was observed between the reference values and the LV parameters estimated by the entire slice set or a sampling intensity of 1/2 (P > .05). For these stereological approaches, a high correlation (r(2) = 0.80-0.93) and clinically acceptable limits of agreement were found with the reference method. Stereological estimations obtained by both sample sizes presented comparable coefficient of variation values of 2.9-5.8%. The mean time for stereological measurements on the entire slice set was 3.4 ± 0.6 minutes and it was reduced to 2.5 ± 0.5 minutes with the 1/2 systematic sampling scheme. Stereological analysis on systematic samples of MR slices generated by the 1/2 sampling intensity provided efficient and quick assessment of LV volumes, function, and mass. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
Towards a unified analysis of brain maturation and aging across the entire lifespan: A MRI analysis.
Coupé, Pierrick; Catheline, Gwenaelle; Lanuza, Enrique; Manjón, José Vicente
2017-11-01
There is no consensus in literature about lifespan brain maturation and senescence, mainly because previous lifespan studies have been performed on restricted age periods and/or with a limited number of scans, making results instable and their comparison very difficult. Moreover, the use of nonharmonized tools and different volumetric measurements lead to a great discrepancy in reported results. Thanks to the new paradigm of BigData sharing in neuroimaging and the last advances in image processing enabling to process baby as well as elderly scans with the same tool, new insights on brain maturation and aging can be obtained. This study presents brain volume trajectory over the entire lifespan using the largest age range to date (from few months of life to elderly) and one of the largest number of subjects (N = 2,944). First, we found that white matter trajectory based on absolute and normalized volumes follows an inverted U-shape with a maturation peak around middle life. Second, we found that from 1 to 8-10 y there is an absolute gray matter (GM) increase related to body growth followed by a GM decrease. However, when normalized volumes were considered, GM continuously decreases all along the life. Finally, we found that this observation holds for almost all the considered subcortical structures except for amygdala which is rather stable and hippocampus which exhibits an inverted U-shape with a longer maturation period. By revealing the entire brain trajectory picture, a consensus can be drawn since most of the previously discussed discrepancies can be explained. Hum Brain Mapp 38:5501-5518, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Clegg, S L; Wexler, A S
2011-04-21
A Pitzer ion interaction model has been applied to the systems H(2)SO(4)-H(2)O (0-3 mol kg(-1), 0-55 °C) and H(2)SO(4)-(NH(4))(2)SO(4)-H(2)O (0-6 mol kg(-1), 25 °C) for the calculation of apparent molar volume and density. The dissociation reaction HSO(4)(-)((aq)) ↔ H(+)((aq)) + SO(4)(2-)((aq)) is treated explicitly. Apparent molar volumes of the SO(4)(2-) ion at infinite dilution were obtained from part 1 of this work, (1) and the value for the bisulfate ion was determined in this study from 0 to 55 °C. In dilute solutions of both systems, the change in the degree of dissociation of the HSO(4)(-) ion with concentration results in much larger variations of the apparent molar volumes of the solutes than for conventional strong (fully dissociated) electrolytes. Densities and apparent molar volumes are tabulated. Apparent molar volumes calculated using the model are combined with other data for the solutes NH(4)HSO(4) and (NH(4))(3)H(SO(4))(2) at 25 °C to obtain apparent molar volumes and densities over the entire concentration range (including solutions supersaturated with respect to the salts).
Kälin, Pascal S; Crawford, Rebecca J; Marcon, Magda; Manoliu, Andrei; Bouaicha, Samy; Fischer, Michael A; Ulbrich, Erika J
2018-04-23
We aimed to provide mean values for fat-fraction and volume for full-length bilateral rotator cuff and deltoid muscles in asymptomatic adults selected on the basis of their good musculoskeletal and systemic health, and to understand the influence of gender, age, and arm dominance. Seventy-six volunteers aged 20 to 60 years who were screened for normal BMI and high general health were included in the study. MRI was performed at 3 Tesla using three-point DIXON sequences. Volume and fat-signal fraction of the rotator cuff muscles and the deltoid muscle were determined with semi-automated segmentation of entire muscle lengths. Differences according to age, gender, and handedness per muscle were evaluated. Fat-signal fractions were comparable between genders (mean ± 2 SD, 95% CI, women 7.0 ± 3.0; 6.8-7.2%, men 6.8 ± 2.7; 6.7-7.0%) but did not show convincing changes with age. Higher shoulder muscle volume and lower fat-signal fraction in the dominant arm were shown for teres minor and deltoid (p < 0.01) with similar trends shown for the other rotator cuff muscles. Bilateral fat-signal fractions and volumes based on entire length shoulder muscles in asymptomatic 20-60 year old adults may provide reference for clinicians. Differences shown according to arm dominance should be considered and may rationalize the need for bilateral imaging in determining appropriate management.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The final report for the project is presented in five volumes. This volume, Detailed Methodology Review, presents a discussion of the methods considered and used to estimate the impacts of Outer Continental Shelf (OCS) oil and gas development on coastal recreation in California. The purpose is to provide the Minerals Management Service with data and methods to improve their ability to analyze the socio-economic impacts of OCS development. Chapter II provides a review of previous attempts to evaluate the effects of OCS development and of oil spills on coastal recreation. The review also discusses the strengths and weaknesses of differentmore » approaches and presents the rationale for the methodology selection made. Chapter III presents a detailed discussion of the methods actually used in the study. The volume contains the bibliography for the entire study.« less
ERIC Educational Resources Information Center
Melaragno, Ralph J.; And Others
Intended to provide a comprehensive view of parental involvement in school districts receiving federal education funds, this study collected data on four federal programs in 57 projects across the country. Titles I and VII of the Elementary Secondary Education Act, the Emergency School Aid Act, and Follow Through were examined. The entire study is…
Timber Volume in Eastern South Dakota, 1980
Ronald L. Hackett
1982-01-01
Eastern South Dakota's 113,600 acres of commercial forest land supported 51.9 million cubic feet of growing stock in 1981. This is a decrease in timber volume of 24 percent since the last inventory in 1965. the decrease was entirely in hardwood species. Cottonwood is the most abundant tree species -- it accounts for 33 percent of the growing-stock volume and...
The report gives results of a study that identifies new and innovative air pollution prevention and/or control technologies, of selected industrialized countries, that are not currently used extensively in the U.S. The technologies may be entirely new to the U.S., or they may be ...
The report gives results of a study that identifies new and innovative air pollution prevention and/or control technologies, of selected industrialized countries, that are not currently used extensively in the U.S. The technologies may be entirely new to the U.S., or they may be ...
NASA Astrophysics Data System (ADS)
Ramanaiah, S.; Rao, C. Narasimha; Nagaraja, P.; Venkateswarlu, P.
2015-11-01
Exces volumes, VE, and excess isentropic compressibilities, κSE, have been reported as a function of composition for binary liquid mixtures of trichloroethylene with ethyl acetate, n-propyl acetate, and n-butyl acetate at 303.15 K. Isentropic compressibilities are calculated using measured sound speeds and density data for pure components and for binary mixtures. Excess volumes and excess isentropic compressibilities are found to be negative for the three systems studied over the entire composition range at 303.15 K, whereas these values become more negative with an increase of carbon chain length. The results are discussed in terms of intermolecular interactions between unlike molecules.
DOT National Transportation Integrated Search
1972-12-01
The purpose of the diagrammatic signing research project was to develop warrants and standards for the use of diagrammatic guide signs on controlled access highways. Volume 1 summarizes the entire diagrammatic signing research program objectives spon...
Dielectric and physiochemical study of binary mixture of nitrobenzene with toluene
NASA Astrophysics Data System (ADS)
Mohod, Ajay G.; Deshmukh, S. D.; Pattebahadur, K. L.; Undre, P. B.; Patil, S. S.; Khirade, P. W.
2018-05-01
This paper presents the study of binary mixture of Nitrobenzene (NB) with Toluene (TOL) for eleven different concentrations at room temperature. The determined Dielectric Constant (ɛ0) Density (ρ) and Refractive index (nD) values of binary mixture are used to calculate the excess properties i.e. Excess Dielectric Constant (ɛ0E), Excess Molar Volume (VmE), Excess Refractive Index (nDE) and Excess Molar Refraction (RmE) of mixture over the entire composition range and fitted to the Redlich-Kister equation. The Kirkwood Correlation Factor (geff) and other parameters were used to discuss the information about the orientation of dipoles and the solute-solvent interaction of binary mixture at molecular level over the entire range of concentration.
Thermo-acoustical molecular interaction study in binary mixtures of glycerol and ethylene glycol
NASA Astrophysics Data System (ADS)
Kaur, Kirandeep; Juglan, K. C.; Kumar, Harsh
2017-07-01
Ultrasonic velocity, density and viscosity are measured over the entire composition range for binary liquid mixtures of glycerol (CH2OH-CHOH-CH2OH) and ethylene glycol (HOCH2CH2OH) at different temperatures and constant frequency of 2MHz using ultrasonic interferometer, specific gravity bottle and viscometer respectively. Measured experimental values are used to obtained various acoustical parameters such as adiabatic compressibility, acoustic impedance, intermolecular free length, relaxation time, ultrasonic attenuation, effective molar weight, free volume, available volume, molar volume, Wada's constant, Rao's constant, Vander Waal's constant, internal pressure, Gibb's free energy and enthalpy. The variation in acoustical parameters are interpreted in terms of molecular interactions between the components of molecules of binary liquid mixtures.
NASA Astrophysics Data System (ADS)
Wang, Shutao; Raju, Balasundar I.; Leyvi, Evgeniy; Weinstein, David A.; Seip, Ralf
2012-10-01
Glycogen storage disease type Ia (GSDIa) is caused by an inherited single-gene defect resulting in an impaired glycogen to glucose conversion pathway. Targeted ultrasound mediated delivery (USMD) of plasmid DNA (pDNA) to liver in conjunction with microbubbles may provide a potential treatment for GSDIa patients. As the success of USMD treatments is largely dependent on the accessibility of the targeted tissue by the focused ultrasound beam, this study presents a quantitative approach to determine the acoustically accessible liver volume in GSDIa patients. Models of focused ultrasound beam profiles for transducers of varying aperture and focal lengths were applied to abdomen models reconstructed from suitable CT and MRI images. Transducer manipulations (simulating USMD treatment procedures) were implemented via transducer translations and rotations with the intent of targeting and exposing the entire liver to ultrasound. Results indicate that acoustically accessible liver volumes can be as large as 50% of the entire liver volume for GSDIa patients and on average 3 times larger compared to a healthy adult group due to GSDIa patients' increased liver size. Detailed descriptions of the evaluation algorithm, transducer-and abdomen models are presented, together with implications for USMD treatments of GSDIa patients and transducer designs for USMD applications.
Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols.
Forst, Darren; Nijjar, Simrit; Flores-Mir, Carlos; Carey, Jason; Secanell, Marc; Lagravere, Manuel
2014-12-23
The objective of this study is to analyze a set of previously developed and proposed image segmentation protocols for precision in both intra- and inter-rater reliability for in vivo tooth volume measurements using cone-beam computed tomography (CBCT) images. Six 3D volume segmentation procedures were proposed and tested for intra- and inter-rater reliability to quantify maxillary first molar volumes. Ten randomly selected maxillary first molars were measured in vivo in random order three times with 10 days separation between measurements. Intra- and inter-rater agreement for all segmentation procedures was attained using intra-class correlation coefficient (ICC). The highest precision was for automated thresholding with manual refinements. A tooth volume measurement protocol for CBCT images employing automated segmentation with manual human refinement on a 2D slice-by-slice basis in all three planes of space possessed excellent intra- and inter-rater reliability. Three-dimensional volume measurements of the entire tooth structure are more precise than 3D volume measurements of only the dental roots apical to the cemento-enamel junction (CEJ).
Volume, value and floristic diversity of Gabon׳s medicinal plant markets.
Towns, Alexandra M; Quiroz, Diana; Guinee, Lieke; de Boer, Hugo; van Andel, Tinde
2014-09-11
African medicinal plant markets offer insight into commercially important species, salient health concerns in the region, and possible conservation priorities. Still, little quantitative data is available on the trade in herbal medicine in Central Africa. The aim of this study was to identify the species, volume, and value of medicinal plant products sold on the major domestic markets in Gabon, Central Africa. We surveyed 21 herbal market stalls across 14 of the major herbal medicine markets in Gabon, collected vouchers of medicinal plants and documented uses, vernacular names, prices, weight, vendor information and weekly sales. From these quantitative data, we extrapolated volumes and values for the entire herbal medicine market. We encountered 263 medicinal plant products corresponding with at least 217 species. Thirteen species were encountered on one-third of the surveyed stalls and 18 species made up almost 50% of the total volume of products available daily, including the fruits of Tetrapleura tetraptera and seeds of Monodora myristica. Although bark comprised the majority of the floristic diversity (22%) and the highest percentage of daily stock (30%), the resin of IUCN red-listed species Aucoumea klaineana represented 20% of the estimated daily volume of the entire herbal market. Plants sold at the market were mainly used for ritual purposes (32%), followed by women׳s health (13%), and childcare (10%). The presence of migrant herbal vendors selling imported species, especially from Benin, was a prominent feature of the Gabonese markets. An estimated volume of 27 t of medicinal plant products worth US$ 1.5 million is sold annually on the main Gabonese markets. Aucoumea klaineana and Garcinia kola are highlighted as frequently sold species with conservation priorities. The herbal market in Gabon is slightly higher in species diversity but lower in volume and value than recently surveyed sub-Saharan African markets. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Dose masking feature for BNCT radiotherapy planning
Cook, Jeremy L.; Wessol, Daniel E.; Wheeler, Floyd J.
2000-01-01
A system for displaying an accurate model of isodoses to be used in radiotherapy so that appropriate planning can be performed prior to actual treatment on a patient. The nature of the simulation of the radiotherapy planning for BNCT and Fast Neutron Therapy, etc., requires that the doses be computed in the entire volume. The "entire volume" includes the patient and beam geometries as well as the air spaces in between. Isodoses derived from the computed doses will therefore extend into the air regions between the patient and beam geometries and thus depict the unrealistic possibility that radiation deposition occurs in regions containing no physical media. This problem is solved by computing the doses for the entire geometry and then masking the physical and air regions along with the isodose contours superimposed over the patient image at the corresponding plane. The user is thus able to mask out (remove) the contour lines from the unwanted areas of the image by selecting the appropriate contour masking region from the raster image.
Age estimation from canine volumes.
De Angelis, Danilo; Gaudio, Daniel; Guercini, Nicola; Cipriani, Filippo; Gibelli, Daniele; Caputi, Sergio; Cattaneo, Cristina
2015-08-01
Techniques for estimation of biological age are constantly evolving and are finding daily application in the forensic radiology field in cases concerning the estimation of the chronological age of a corpse in order to reconstruct the biological profile, or of a living subject, for example in cases of immigration of people without identity papers from a civil registry. The deposition of teeth secondary dentine and consequent decrease of pulp chamber in size are well known as aging phenomena, and they have been applied to the forensic context by the development of age estimation procedures, such as Kvaal-Solheim and Cameriere methods. The present study takes into consideration canines pulp chamber volume related to the entire teeth volume, with the aim of proposing new regression formulae for age estimation using 91 cone beam computerized scans and a freeware open-source software, in order to permit affordable reproducibility of volumes calculation.
Free Volume Structure of Acrylic-Type Dental Nanocomposites Tested with Annihilating Positrons.
Shpotyuk, Olha; Ingram, Adam; Shpotyuk, Oleh
2016-12-01
Positron annihilation spectroscopy in lifetime measuring mode exploring conventional fast-fast coincidence ORTEC system is employed to characterize free volume structure of commercially available acrylic-type dental restorative composite Charisma® (Heraeus Kulzer GmbH, Germany). The measured lifetime spectra for uncured and light-cured composites are reconstructed from unconstrained x3-term fitting and semi-empirical model exploring x3-x2-coupling decomposition algorithm. The governing channel of positron annihilation in the composites studied is ascribed to mixed positron-Ps trapping, where Ps decaying in the third component is caused entirely by input from free-volume holes in polymer matrix, while the second component is defined by free positron trapping in interfacial free-volume holes between filler nanoparticles and surrounded polymer matrix. Microstructure scenario of the photopolymerization shrinkage includes cross-linking of structural chains in polymer matrix followed by conversion of bound positron-electron (positronium) traps in positron-trapping interfacial free-volume voids in a vicinity of agglomerated filler nanoparticles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayo, Charles, E-mail: charles.mayo@umassmemorial.or; Yorke, Ellen; Merchant, Thomas E.
Publications relating brainstem radiation toxicity to quantitative dose and dose-volume measures derived from three-dimensional treatment planning were reviewed. Despite the clinical importance of brainstem toxicity, most studies reporting brainstem effects after irradiation have fewer than 100 patients. There is limited evidence relating toxicity to small volumes receiving doses above 60-64 Gy using conventional fractionation and no definitive criteria regarding more subtle dose-volume effects or effects after hypofractionated treatment. On the basis of the available data, the entire brainstem may be treated to 54 Gy using conventional fractionation using photons with limited risk of severe or permanent neurological effects. Smaller volumesmore » of the brainstem (1-10 mL) may be irradiated to maximum doses of 59 Gy for dose fractions <=2 Gy; however, the risk appears to increase markedly at doses >64 Gy.« less
Progressive Atelectasis Secondary to GSW to Airway
2009-05-01
compression, cicatrization , adhesion and Progressive Atelectasis Secondary to GSW Military Medicine Radiology Corner, Volume 174 May 2009...in retraction or entire collapse of lung lobes. The next main cause of atelectasis, cicatrization , is also produced by the interaction of...mechanical forces. In cicatrization atelectasis, pulmonary fibrosis stiffens the alveoli, causing a decrease in compliance and alveolar volume
NASA Technical Reports Server (NTRS)
McCurry, J.
1995-01-01
The purpose of the TA-2 contract was to provide advanced launch vehicle concept definition and analysis to assist NASA in the identification of future launch vehicle requirements. Contracted analysis activities included vehicle sizing and performance analysis, subsystem concept definition, propulsion subsystem definition (foreign and domestic), ground operations and facilities analysis, and life cycle cost estimation. This document is part of the final report for the TA-2 contract. The final report consists of three volumes: Volume 1 is the Executive Summary, Volume 2 is Technical Results, and Volume 3 is Program Cost Estimates. The document-at-hand, Volume 1, provides a summary description of the technical activities that were performed over the entire contract duration, covering three distinct launch vehicle definition activities: heavy-lift (300,000 pounds injected mass to low Earth orbit) launch vehicles for the First Lunar Outpost (FLO), medium-lift (50,000-80,000 pounds injected mass to low Earth orbit) launch vehicles, and single-stage-to-orbit (SSTO) launch vehicles (25,000 pounds injected mass to a Space Station orbit).
Radial Internal Material Handling System (RIMS) for Circular Habitat Volumes
NASA Technical Reports Server (NTRS)
Howe, Alan S.; Haselschwardt, Sally; Bogatko, Alex; Humphrey, Brian; Patel, Amit
2013-01-01
On planetary surfaces, pressurized human habitable volumes will require a means to carry equipment around within the volume of the habitat, regardless of the partial gravity (Earth, Moon, Mars, etc.). On the NASA Habitat Demonstration Unit (HDU), a vertical cylindrical volume, it was determined that a variety of heavy items would need to be carried back and forth from deployed locations to the General Maintenance Work Station (GMWS) when in need of repair, and other equipment may need to be carried inside for repairs, such as rover parts and other external equipment. The vertical cylindrical volume of the HDU lent itself to a circular overhead track and hoist system that allows lifting of heavy objects from anywhere in the habitat to any other point in the habitat interior. In addition, the system is able to hand-off lifted items to other material handling systems through the side hatches, such as through an airlock. The overhead system consists of two concentric circle tracks that have a movable beam between them. The beam has a hoist carriage that can move back and forth on the beam. Therefore, the entire system acts like a bridge crane curved around to meet itself in a circle. The novelty of the system is in its configuration, and how it interfaces with the volume of the HDU habitat. Similar to how a bridge crane allows coverage for an entire rectangular volume, the RIMS system covers a circular volume. The RIMS system is the first generation of what may be applied to future planetary surface vertical cylinder habitats on the Moon or on Mars.
1977-04-01
extreme is the viewpoint that such analyses are modern types of witchcraft , or numerology, practiced by a priestly cast. Results and con- clusions...simplistic approach is often respon- sible for imparting a bad reputation to an entire field of analysis - and deserves the label of witchcraft or
Preface to the special volume on the second Sandia Fracture Challenge
Kramer, Sharlotte Lorraine Bolyard; Boyce, Brad
2016-01-01
In this study, ductile failure of structural metals is a pervasive issue for applications such as automotive manufacturing, transportation infrastructures, munitions and armor, and energy generation. Experimental investigation of all relevant failure scenarios is intractable, requiring reliance on computation models. Our confidence in model predictions rests on unbiased assessments of the entire predictive capability, including the mathematical formulation, numerical implementation, calibration, and execution.
Method and apparatus for probing relative volume fractions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jandrasits, W.G.; Kikta, T.J.
1996-12-31
A relative volume fraction probe particularly for use in a multiphase fluid system includes two parallel conductive paths defining there between a sample zone within the system. A generating unit generates time varying electrical signals which are inserted into one of the two parallel conductive paths. A time domain reflectometer receives the time varying electrical signals returned by the second of the two parallel conductive paths and, responsive thereto, outputs a curve of impedance versus distance. An analysis unit then calculates the area under the curve, subtracts the calculated area from an area produced when the sample zone consists entirelymore » of material of a first fluid phase, and divides this calculated difference by the difference between an area produced when the sample zone consists entirely of material of the first fluid phase and an area produced when the sample zone consists entirely of material of a second fluid phase. The result is the volume fraction.« less
RIGHT AND LEFT VENTRICULAR DIASTOLIC PRESSURE–VOLUME RELATIONS: A COMPREHENSIVE REVIEW
Pasipoularides, Ares
2012-01-01
Ventricular compliance alterations can affect cardiac performance and adaptations. Moreover, diastolic mechanics are important in assessing both diastolic and systolic function, since any filling impairment can compromise systolic function. A sigmoidal passive filling pressure-volume relationship, developed using chronically instrumented, awake-animal disease models, is clinically adaptable to evaluating diastolic dynamics using subject-specific micromanometric and volumetric data from the entire filling period of any heartbeat(s). This innovative relationship is the global, integrated expression of chamber geometry, wall thickness, and passive myocardial wall properties. Chamber and myocardial compliance curves of both ventricles can be computed by the sigmoidal methodology over the entire filling period and plotted over appropriate filling pressure ranges. Important characteristics of the compliance curves can be examined and compared between the right and the left ventricle, and for different physiological and pathological conditions. The sigmoidal paradigm is more accurate and, therefore, a better alternative to the conventional exponential pressure-volume approximation. PMID:23179133
NLT and extrapolated DLT:3-D cinematography alternatives for enlarging the volume of calibration.
Hinrichs, R N; McLean, S P
1995-10-01
This study investigated the accuracy of the direct linear transformation (DLT) and non-linear transformation (NLT) methods of 3-D cinematography/videography. A comparison of standard DLT, extrapolated DLT, and NLT calibrations showed the standard (non-extrapolated) DLT to be the most accurate, especially when a large number of control points (40-60) were used. The NLT was more accurate than the extrapolated DLT when the level of extrapolation exceeded 100%. The results indicated that when possible one should use the DLT with a control object, sufficiently large as to encompass the entire activity being studied. However, in situations where the activity volume exceeds the size of one's DLT control object, the NLT method should be considered.
Depping, Malte S; Wolf, Nadine D; Vasic, Nenad; Sambataro, Fabio; Thomann, Philipp A; Christian Wolf, R
2015-03-15
Abnormal brain volume has been frequently demonstrated in major depressive disorder (MDD). It is unclear if these findings are specific for MDD since aberrant brain structure is also present in disorders with depressive comorbidity and affective dysregulation, such as borderline personality disorder (BPD). In this transdiagnostic study, we aimed to investigate if regional brain volume loss differentiates between MDD and BPD. Further, we tested for associations between brain volume and clinical variables within and between diagnostic groups. 22 Females with a DSM-IV diagnosis of MDD, 17 females with a DSM-IV diagnosis of BPD and without comorbid posttraumatic stress disorder, and 22 age-matched female healthy controls (HC) were investigated using magnetic resonance imaging. High-resolution structural data were analyzed using voxel-based morphometry. A significant (p<0.05, cluster-corrected) volume decrease of the anterior cingulate cortex (ACC) was found in MDD compared to HC, as opposed to volume decreases of the amygdala in BPD compared to both HC and MDD. Sensitivity and specificity of regional gray matter volume for a diagnosis of MDD were modest to fair. Amygdala volume was related to depressive symptoms across the entire patient sample. Potential limitations of this study include the modest sample size and the heterogeneous psychotropic drug treatment. ACC volume reduction is more pronounced in MDD with an intermediate degree of volume loss in BPD compared to HC. In contrast, amygdala volume loss is more pronounced in BPD compared to MDD, yet amygdala volume is associated with affective symptom expression in both disorders. Copyright © 2014 Elsevier B.V. All rights reserved.
Post-stratified estimation of forest area and growing stock volume using lidar-based stratifications
Ronald E. McRoberts; Terje Gobakken; Erik Næsset
2012-01-01
National forest inventories report estimates of parameters related to forest area and growing stock volume for geographic areas ranging in size from municipalities to entire countries. Landsat imagery has been shown to be a source of auxiliary information that can be used with stratified estimation to increase the precision of estimates, although the increase is...
Navy Coalescence Test on Petroleum F-76 Fuel with FAME Additive at 1%
2012-06-20
sponsored studies have shown that in many countries there is an undesirable concentration of Fatty Acid Methyl - Ester ( FAME ) present in the F-76. This...have shown that in many countries there may be an undesirable concentration of Fatty Acid Methyl - Ester ( FAME ) present in the F-76. This study was...Acid Methyl - Ester DEFINITIONS Turnover ..................amount of time it takes to flow the entire volume of fluid in a container, also
Bhattarai, Ajaya; Chatterjee, Sujeet Kumar; Niraula, Tulasi Prasad
2013-01-01
The accurate measurements on density of the binary mixtures of cetyltrimethylammonium bromide and sodium dodecyl sulphate in pure water and in methanol(1) + water (2) mixed solvent media containing (0.10, 0.20, and 0.30) volume fractions of methanol at 308.15, 318.15, and 323.15 K are reported. The concentrations are varied from (0.03 to 0.12) mol.l(-1) of sodium dodecyl sulphate in presence of ~ 5.0×10(-4) mol.l(-1) cetyltrimethylammonium bromide. The results showed almost increase in the densities with increasing surfactant mixture concentration, also the densities are found to decrease with increasing temperature over the entire concentration range, investigated in a given mixed solvent medium and these values are found to decrease with increasing methanol content in the solvent composition. The concentration dependence of the apparent molar volumes appear to be negligible over the entire concentration range, investigated in a given mixed solvent medium and the apparent molar volumes increase with increasing temperature and are found to decrease with increasing methanol content in the solvent composition.
Kerbler, Georg M.; Nedelska, Zuzana; Fripp, Jurgen; Laczó, Jan; Vyhnalek, Martin; Lisý, Jiří; Hamlin, Adam S.; Rose, Stephen; Hort, Jakub; Coulson, Elizabeth J.
2015-01-01
The basal forebrain degenerates in Alzheimer’s disease (AD) and this process is believed to contribute to the cognitive decline observed in AD patients. Impairment in spatial navigation is an early feature of the disease but whether basal forebrain dysfunction in AD is responsible for the impaired navigation skills of AD patients is not known. Our objective was to investigate the relationship between basal forebrain volume and performance in real space as well as computer-based navigation paradigms in an elderly cohort comprising cognitively normal controls, subjects with amnestic mild cognitive impairment and those with AD. We also tested whether basal forebrain volume could predict the participants’ ability to perform allocentric- vs. egocentric-based navigation tasks. The basal forebrain volume was calculated from 1.5 T magnetic resonance imaging (MRI) scans, and navigation skills were assessed using the human analog of the Morris water maze employing allocentric, egocentric, and mixed allo/egocentric real space as well as computerized tests. When considering the entire sample, we found that basal forebrain volume correlated with spatial accuracy in allocentric (cued) and mixed allo/egocentric navigation tasks but not the egocentric (uncued) task, demonstrating an important role of the basal forebrain in mediating cue-based spatial navigation capacity. Regression analysis revealed that, although hippocampal volume reflected navigation performance across the entire sample, basal forebrain volume contributed to mixed allo/egocentric navigation performance in the AD group, whereas hippocampal volume did not. This suggests that atrophy of the basal forebrain contributes to aspects of navigation impairment in AD that are independent of hippocampal atrophy. PMID:26441643
Optimized volume models of earthquake-triggered landslides
Xu, Chong; Xu, Xiwei; Shen, Lingling; Yao, Qi; Tan, Xibin; Kang, Wenjun; Ma, Siyuan; Wu, Xiyan; Cai, Juntao; Gao, Mingxing; Li, Kang
2016-01-01
In this study, we proposed three optimized models for calculating the total volume of landslides triggered by the 2008 Wenchuan, China Mw 7.9 earthquake. First, we calculated the volume of each deposit of 1,415 landslides triggered by the quake based on pre- and post-quake DEMs in 20 m resolution. The samples were used to fit the conventional landslide “volume-area” power law relationship and the 3 optimized models we proposed, respectively. Two data fitting methods, i.e. log-transformed-based linear and original data-based nonlinear least square, were employed to the 4 models. Results show that original data-based nonlinear least square combining with an optimized model considering length, width, height, lithology, slope, peak ground acceleration, and slope aspect shows the best performance. This model was subsequently applied to the database of landslides triggered by the quake except for two largest ones with known volumes. It indicates that the total volume of the 196,007 landslides is about 1.2 × 1010 m3 in deposit materials and 1 × 1010 m3 in source areas, respectively. The result from the relationship of quake magnitude and entire landslide volume related to individual earthquake is much less than that from this study, which reminds us the necessity to update the power-law relationship. PMID:27404212
Optimized volume models of earthquake-triggered landslides.
Xu, Chong; Xu, Xiwei; Shen, Lingling; Yao, Qi; Tan, Xibin; Kang, Wenjun; Ma, Siyuan; Wu, Xiyan; Cai, Juntao; Gao, Mingxing; Li, Kang
2016-07-12
In this study, we proposed three optimized models for calculating the total volume of landslides triggered by the 2008 Wenchuan, China Mw 7.9 earthquake. First, we calculated the volume of each deposit of 1,415 landslides triggered by the quake based on pre- and post-quake DEMs in 20 m resolution. The samples were used to fit the conventional landslide "volume-area" power law relationship and the 3 optimized models we proposed, respectively. Two data fitting methods, i.e. log-transformed-based linear and original data-based nonlinear least square, were employed to the 4 models. Results show that original data-based nonlinear least square combining with an optimized model considering length, width, height, lithology, slope, peak ground acceleration, and slope aspect shows the best performance. This model was subsequently applied to the database of landslides triggered by the quake except for two largest ones with known volumes. It indicates that the total volume of the 196,007 landslides is about 1.2 × 10(10) m(3) in deposit materials and 1 × 10(10) m(3) in source areas, respectively. The result from the relationship of quake magnitude and entire landslide volume related to individual earthquake is much less than that from this study, which reminds us the necessity to update the power-law relationship.
Estimating the volume of glaciers in the Himalayan-Karakoram region using different methods
NASA Astrophysics Data System (ADS)
Frey, H.; Machguth, H.; Huss, M.; Huggel, C.; Bajracharya, S.; Bolch, T.; Kulkarni, A.; Linsbauer, A.; Salzmann, N.; Stoffel, M.
2014-12-01
Ice volume estimates are crucial for assessing water reserves stored in glaciers. Due to its large glacier coverage, such estimates are of particular interest for the Himalayan-Karakoram (HK) region. In this study, different existing methodologies are used to estimate the ice reserves: three area-volume relations, one slope-dependent volume estimation method, and two ice-thickness distribution models are applied to a recent, detailed, and complete glacier inventory of the HK region, spanning over the period 2000-2010 and revealing an ice coverage of 40 775 km2. An uncertainty and sensitivity assessment is performed to investigate the influence of the observed glacier area and important model parameters on the resulting total ice volume. Results of the two ice-thickness distribution models are validated with local ice-thickness measurements at six glaciers. The resulting ice volumes for the entire HK region range from 2955 to 4737 km3, depending on the approach. This range is lower than most previous estimates. Results from the ice thickness distribution models and the slope-dependent thickness estimations agree well with measured local ice thicknesses. However, total volume estimates from area-related relations are larger than those from other approaches. The study provides evidence on the significant effect of the selected method on results and underlines the importance of a careful and critical evaluation.
Raphael, David T; McIntee, Diane; Tsuruda, Jay S; Colletti, Patrick; Tatevossian, Ray
2005-12-01
Magnetic resonance neurography (MRN) is an imaging method by which nerves can be selectively highlighted. Using commercial software, the authors explored a variety of approaches to develop a three-dimensional volume-rendered MRN image of the entire brachial plexus and used it to evaluate the accuracy of infraclavicular block approaches. With institutional review board approval, MRN of the brachial plexus was performed in 10 volunteer subjects. MRN imaging was performed on a GE 1.5-tesla magnetic resonance scanner (General Electric Healthcare Technologies, Waukesha, WI) using a phased array torso coil. Coronal STIR and T1 oblique sagittal sequences of the brachial plexus were obtained. Multiple software programs were explored for enhanced display and manipulation of the composite magnetic resonance images. The authors developed a frontal slab composite approach that allows single-frame reconstruction of a three-dimensional volume-rendered image of the entire brachial plexus. Automatic segmentation was supplemented by manual segmentation in nearly all cases. For each of three infraclavicular approaches (posteriorly directed needle below midclavicle, infracoracoid, or caudomedial to coracoid), the targeting error was measured as the distance from the MRN plexus midpoint to the approach-targeted site. Composite frontal slabs (coronal views), which are single-frame three-dimensional volume renderings from image-enhanced two-dimensional frontal view projections of the underlying coronal slices, were created. The targeting errors (mean +/- SD) for the approaches-midclavicle, infracoracoid, caudomedial to coracoid-were 0.43 +/- 0.67, 0.99 +/- 1.22, and 0.65 +/- 1.14 cm, respectively. Image-processed three-dimensional volume-rendered MNR scans, which allow visualization of the entire brachial plexus within a single composite image, have educational value in illustrating the complexity and individual variation of the plexus. Suggestions for improved guidance during infraclavicular block procedures are presented.
NASA Technical Reports Server (NTRS)
Jasperson, W. H.; Nastron, G. D.; Davis, R. E.; Holdeman, J. D.
1984-01-01
Summary studies are presented for the entire cloud observation archive from the NASA Global Atmospheric Sampling Program (GASP). Studies are also presented for GASP particle-concentration data gathered concurrently with the cloud observations. Cloud encounters are shown on about 15 percent of the data samples overall, but the probability of cloud encounter is shown to vary significantly with altitude, latitude, and distance from the tropopause. Several meteorological circulation features are apparent in the latitudinal distribution of cloud cover, and the cloud-encounter statistics are shown to be consistent with the classical mid-latitude cyclone model. Observations of clouds spaced more closely than 90 minutes are shown to be statistically dependent. The statistics for cloud and particle encounter are utilized to estimate the frequency of cloud encounter on long-range airline routes, and to assess the probability and extent of laminaar flow loss due to cloud or particle encounter by aircraft utilizing laminar flow control (LFC). It is shown that the probability of extended cloud encounter is too low, of itself, to make LFC impractical. This report is presented in two volumes. Volume I contains the narrative, analysis, and conclusions. Volume II contains five supporting appendixes.
High tidal volume ventilation in infant mice.
Cannizzaro, Vincenzo; Zosky, Graeme R; Hantos, Zoltán; Turner, Debra J; Sly, Peter D
2008-06-30
Infant mice were ventilated with either high tidal volume (V(T)) with zero end-expiratory pressure (HVZ), high V(T) with positive end-expiratory pressure (PEEP) (HVP), or low V(T) with PEEP. Thoracic gas volume (TGV) was determined plethysmographically and low-frequency forced oscillations were used to measure the input impedance of the respiratory system. Inflammatory cells, total protein, and cytokines in bronchoalveolar lavage fluid (BALF) and interleukin-6 (IL-6) in serum were measured as markers of pulmonary and systemic inflammatory response, respectively. Coefficients of tissue damping and tissue elastance increased in all ventilated mice, with the largest rise seen in the HVZ group where TGV rapidly decreased. BALF protein levels increased in the HVP group, whereas serum IL-6 rose in the HVZ group. PEEP keeps the lungs open, but provides high volumes to the entire lungs and induces lung injury. Compared to studies in adult and non-neonatal rodents, infant mice demonstrate a different response to similar ventilation strategies underscoring the need for age-specific animal models.
Using an ultrasound elasticity microscope to map three-dimensional strain in a porcine cornea.
Hollman, Kyle W; Shtein, Roni M; Tripathy, Sakya; Kim, Kang
2013-08-01
An ultrasound elasticity microscope was used to map 3-D strain volume in an ex vivo porcine cornea to illustrate its ability to measure the mechanical properties of this tissue. Mechanical properties of the cornea play an important role in its function and, therefore, also in ophthalmic diseases such as kerataconus and corneal ectasia. The ultrasound elasticity microscope combines a tightly focused high-frequency transducer with confocal scanning to produce high-quality speckle over the entire volume of tissue. This system and the analysis were able to generate volume maps of compressional strain in all three directions for porcine corneal tissue, more information than any previous study has reported. Strain volume maps indicated features of the cornea and mechanical behavior as expected. These results constitute a step toward better understanding of corneal mechanics and better treatment of corneal diseases. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Morphological phenotyping of mouse hearts using optical coherence tomography
NASA Astrophysics Data System (ADS)
Cua, Michelle; Lin, Eric; Lee, Ling; Sheng, Xiaoye; Wong, Kevin S. K.; Tibbits, Glen F.; Beg, Mirza Faisal; Sarunic, Marinko V.
2014-11-01
Transgenic mouse models have been instrumental in the elucidation of the molecular mechanisms behind many genetically based cardiovascular diseases such as Marfan syndrome (MFS). However, the characterization of their cardiac morphology has been hampered by the small size of the mouse heart. In this report, we adapted optical coherence tomography (OCT) for imaging fixed adult mouse hearts, and applied tools from computational anatomy to perform morphometric analyses. The hearts were first optically cleared and imaged from multiple perspectives. The acquired volumes were then corrected for refractive distortions, and registered and stitched together to form a single, high-resolution OCT volume of the whole heart. From this volume, various structures such as the valves and myofibril bundles were visualized. The volumetric nature of our dataset also allowed parameters such as wall thickness, ventricular wall masses, and luminal volumes to be extracted. Finally, we applied the entire acquisition and processing pipeline in a preliminary study comparing the cardiac morphology of wild-type mice and a transgenic mouse model of MFS.
NASA Technical Reports Server (NTRS)
1984-01-01
The two manufacturing concepts developed represent innovative, technologically advanced manufacturing schemes. The concepts were selected to facilitate an in depth analysis of manufacturing automation requirements in the form of process mechanization, teleoperation and robotics, and artificial intelligence. While the cost effectiveness of these facilities has not been analyzed as part of this study, both appear entirely feasible for the year 2000 timeframe. The growing demand for high quality gallium arsenide microelectronics may warrant the ventures.
Systems cost/performance analysis; study 2.3. Volume 3: Programmer's manual and user's guide
NASA Technical Reports Server (NTRS)
1975-01-01
The implementation of the entire systems cost/performance model as a digital computer program was studied. A discussion of the operating environment in which the program was written and checked, the program specifications such as discussions of logic and computational flow, the different subsystem models involved in the design of the spacecraft, and routines involved in the nondesign area such as costing and scheduling of the design were covered. Preliminary results for the DSCS-2 design are also included.
Snyder, Noah P.; Rubin, David M.; Alpers, Charles N.; Childs, Jonathan R.; Curtis, Jennifer A.; Flint, Lorraine E.; Wright, Scott A.
2004-01-01
Studies of reservoir sedimentation are vital to understanding scientific and management issues related to watershed sediment budgets, depositional processes, reservoir operations, and dam decommissioning. Here we quantify the mass, organic content, and grain-size distribution of a reservoir deposit in northern California by two methods of extrapolating measurements of sediment physical properties from cores to the entire volume of impounded material. Englebright Dam, completed in 1940, is located on the Yuba River in the Sierra Nevada foothills. A research program is underway to assess the feasibility of introducing wild anadromous fish species to the river upstream of the dam. Possible management scenarios include removing or lowering the dam, which could cause downstream transport of stored sediment. In 2001 the volume of sediments deposited behind Englebright Dam occupied 25.5% of the original reservoir capacity. The physical properties of this deposit were calculated using data from a coring campaign that sampled the entire reservoir sediment thickness (6–32 m) at six locations in the downstream ∼3/4 of the reservoir. As a result, the sediment in the downstream part of the reservoir is well characterized, but in the coarse, upstream part of the reservoir, only surficial sediments were sampled, so calculations there are more uncertain. Extrapolation from one-dimensional vertical sections of sediment sampled in cores to entire three-dimensional volumes of the reservoir deposit is accomplished via two methods, using assumptions of variable and constant layer thickness. Overall, the two extrapolation methods yield nearly identical estimates of the mass of the reservoir deposit of ∼26 × 106 metric tons (t) of material, of which 64.7–68.5% is sand and gravel. Over the 61 year reservoir history this corresponds to a maximum basin-wide sediment yield of ∼340 t/km2/yr, assuming no contribution from upstream parts of the watershed impounded by other dams. The uncertainties and limitations of the estimates of overall sediment quantities are discussed. Implications for watershed management and future reservoir sedimentation studies are also presented.
NASA Astrophysics Data System (ADS)
Shin, Yongjin; Jung, Woo-Sang; Lee, Young-Su
2016-11-01
In this study, we use the quasi-harmonic Debye model to predict the coefficient of thermal expansion of Ni- X binary alloys. The method bridges between the macroscopic elastic behavior and thermodynamic properties of materials without an expensive calculation of the volume dependence of the phonon density of states. Furthermore, the Grüneisen parameter is derived from the volume dependence of the Debye temperature, which is calculated from the first-principles elastic stiffness constants. The experimental coefficient of thermal expansion (CTE) of pure nickel is well reproduced, especially in the low temperature region. Among the few alloying elements tested, Al is predicted to slightly decrease the CTE whereas Mo and W are more effective in reducing the CTE. For the cases of Ni-X binary alloy systems, where the variation in the CTE is relatively small, the method used here appears to perform better than certain other formulations that rely entirely on the energy vs. volume relationship.
Fernández, Rafael; Altaba, Susana; Cabre, Lluis; Lacueva, Victoria; Santos, Antonio; Solsona, Jose-Felipe; Añon, Jose-Manuel; Catalan, Rosa-Maria; Gutierrez, Maria-Jose; Fernandez-Cid, Ramon; Gomez-Tello, Vicente; Curiel, Emilio; Fernandez-Mondejar, Enrique; Oliva, Joan-Carles; Tizon, Ana Isabel; Gonzalez, Javier; Monedero, Pablo; Sanchez, Manuela Garcia; de la Torre, M Victoria; Ibañez, Pedro; Frutos, Fernando; Del Nogal, Frutos; Gomez, M Jesus; Marcos, Alfredo; Vera, Paula; Serrano, Jose Manuel; Umaran, Isabel; Carrillo, Andres; Lopez-Pueyo, M-Jose; Rascado, Pedro; Balerdi, Begoña; Suberviola, Borja; Hernandez, Gonzalo
2013-10-01
Recent studies have found an association between increased volume and increased intensive care unit (ICU) survival; however, this association might not hold true in ICUs with permanent intensivist coverage. Our objective was to determine whether ICU volume correlates with survival in the Spanish healthcare system. Post hoc analysis of a prospective study of all patients admitted to 29 ICUs during 3 months. At ICU discharge, the authors recorded demographic variables, severity score, and specific ICU treatments. Follow-up variables included ICU readmission and hospital mortality. Statistics include logistic multivariate analyses for hospital mortality according to quartiles of volume of patients. The authors studied 4,001 patients with a mean predicted risk of death of 23% (range at hospital level: 14-46%). Observed hospital mortality was 19% (range at hospital level: 11-35%), resulting in a standardized mortality ratio of 0.81 (range: 0.5-1.3). Among the 1,923 patients needing mechanical ventilation, the predicted risk of death was 32% (14-60%) and observed hospital mortality was 30% (12-61%), resulting in a standardized mortality ratio of 0.96 (0.5-1.7). The authors found no correlation between standardized mortality ratio and ICU volume in the entire population or in mechanically ventilated patients. Only mechanically ventilated patients in very low-volume ICUs had slightly worse outcome. In the currently studied healthcare system characterized by 24/7 intensivist coverage, the authors found wide variability in outcome among ICUs even after adjusting for severity of illness but no relationship between ICU volume and outcome. Only mechanically ventilated patients in very low-volume centers had slightly worse outcomes.
Earth-like sand fluxes on Mars.
Bridges, N T; Ayoub, F; Avouac, J-P; Leprince, S; Lucas, A; Mattson, S
2012-05-09
Strong and sustained winds on Mars have been considered rare, on the basis of surface meteorology measurements and global circulation models, raising the question of whether the abundant dunes and evidence for wind erosion seen on the planet are a current process. Recent studies showed sand activity, but could not determine whether entire dunes were moving--implying large sand fluxes--or whether more localized and surficial changes had occurred. Here we present measurements of the migration rate of sand ripples and dune lee fronts at the Nili Patera dune field. We show that the dunes are near steady state, with their entire volumes composed of mobile sand. The dunes have unexpectedly high sand fluxes, similar, for example, to those in Victoria Valley, Antarctica, implying that rates of landscape modification on Mars and Earth are similar.
Mechanisms of boron fiber strengthening by thermal treatment
NASA Technical Reports Server (NTRS)
Dicarlo, J. A.
1979-01-01
The fracture strain for boron on tungsten fibers was studied for improvement by heat treatment under vacuum or argon environments. The mechanical basis for this improvement is thermally-induced axial contraction of the entire fiber, whereby strength-controlling core flaws are compressed and fiber fracture strain increased by the value of the contraction strain. By highly sensitive measurements of fiber density and volume, the physical mechanism responsible for contraction under both environments was identified as boron atom diffusion out of the fiber sheath. The fiber contracts because the average volume of the resulting microvoid was determined to be only 0.26 plus or minus 0.09 the average atomic volume of the removed atom. The basic and practical implications of these results are discussed with particular emphasis on the theory, use, and limitations of heat-induced contraction as a simple cost-effective secondary processing method.
ERIC Educational Resources Information Center
Glenwick, David S., Ed.; Jason, Leonard A., Ed.
In the last decade, there has been increased attention paid to the scope of mental and physical health problems that affect individuals at different points over the entire life span. This volume presents many problem areas and the range of their impact on individuals, families, and society at large. The impact of intervention programs is described…
NASA Technical Reports Server (NTRS)
Bhandari, Pradeep; Dudik, Brenda; Birur, Gajanana; Karlmann, Paul; Bame, David; Mastropietro, A. J.
2012-01-01
For single phase mechanically pumped fluid loops used for thermal control of spacecraft, a gas charged accumulator is typically used to modulate pressures within the loop. This is needed to accommodate changes in the working fluid volume due to changes in the operating temperatures as the spacecraft encounters varying thermal environments during its mission. Overall, the three key requirements on the accumulator to maintain an appropriate pressure range throughout the mission are: accommodation of the volume change of the fluid due to temperature changes, avoidance of pump cavitation and prevention of boiling in the liquid. The sizing and design of such an accumulator requires very careful and accurate accounting of temperature distribution within each element of the working fluid for the entire range of conditions expected, accurate knowledge of volume of each fluid element, assessment of corresponding pressures needed to avoid boiling in the liquid, as well as the pressures needed to avoid cavitation in the pump. The appropriate liquid and accumulator strokes required to accommodate the liquid volume change, as well as the appropriate gas volumes, require proper sizing to ensure that the correct pressure range is maintained during the mission. Additionally, a very careful assessment of the process for charging both the gas side and the liquid side of the accumulator is required to properly position the bellows and pressurize the system to a level commensurate with requirements. To achieve the accurate sizing of the accumulator and the charging of the system, sophisticated EXCEL based spreadsheets were developed to rapidly come up with an accumulator design and the corresponding charging parameters. These spreadsheets have proven to be computationally fast and accurate tools for this purpose. This paper will describe the entire process of designing and charging the system, using a case study of the Mars Science Laboratory (MSL) fluid loops, which is en route to Mars for an August 2012 landing.
SU-E-J-242: Volume-Dependence of Quantitative Imaging Features From CT and CE-CT Images of NSCLC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fave, X; Fried, D; UT Health Science Center Graduate School of Biomedical Sciences, Houston, TX
Purpose: To determine whether tumor volume plays a significant role in the values obtained for texture features when they are extracted from computed tomography (CT) images of non-small cell lung cancer (NSCLC). We also sought to identify whether features can be reliably measured at all volumes or if a minimum volume threshold should be recommended. Methods: Eleven features were measured on 40 CT and 32 contrast-enhanced CT (CECT) patient images for this study. Features were selected for their prognostic/diagnostic value in previous publications. Direct correlations between these textures and volume were evaluated using the Spearman correlation coefficient. Any texture thatmore » the Wilcoxon rank-sum test was used to compare the variation above and below a volume cutoff. Four different volume thresholds (5, 10, 15, and 20 cm{sup 3}) were tested. Results: Four textures were found to be significantly correlated with volume in both the CT and CE-CT images. These were busyness, coarseness, gray-level nonuniformity, and run-length nonuniformity with correlation coefficients of 0.92, −0.96, 0.94, and 0.98 for the CT images and 0.95, −0.97, 0.98, and 0.98 for the CE-CT images. After volume normalization, the correlation coefficients decreased substantially. For the data obtained from the CT images, the results of the Wilcoxon rank-sum test were significant when volume thresholds of 5–15 cm3 were used. No volume threshold was shown to be significant for the CE-CT data. Conclusion: Equations for four features that have been used in several published studies were found to be volume-dependent. Future studies should consider implementing normalization factors or removing these features entirely to prevent this potential source of redundancy or bias. This work was supported in part by National Cancer Institute grant R03CA178495-01. Xenia Fave is a recipient of the American Association of Physicists in Medicine Graduate Fellowship.« less
Meteorite Material Model for Structural Properties
NASA Astrophysics Data System (ADS)
Agrawal, P.; Carlozzi, A. A.; Karajeh, Z. S.; Bryson, K. L.
2017-07-01
In order to prepare material models for the entire family of asteroids, meteorite units are developed for ordinary chondrites. The meteorite unit is a representative volume that accounts for diverse minerals, porosity, cracks and matrix composition.
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3MW MOD-5A wind turbine generator is documented. The report is divided into four volumes: Volume 1 summarizes the entire MOD-5A program, Volume 2 discusses the conceptual and preliminary design phases, Volume 3 describes the final design of the MOD-5A, and Volume 4 contains the drawings and specifications developed for the final design. Volume 3, book 2 describes the performance and characteristics of the MOD-5A wind turbine generator in its final configuration. The subsystem for power generation, control, and instrumentation subsystems is described in detail. The manufacturing and construction plans, and the preparation of a potential site on Oahu, Hawaii, are documented. The quality assurance and safety plan, and analyses of failure modes and effects, and reliability, availability and maintainability are presented.
Civil Engineering Corrosion Control. Volume 3. Cathodic Protection Design
1975-02-01
coatings, test stations bonds, and insulation. It is certainly not a "cure-all Its economics and feasibility mus’ always be carefully studied .. An in...General Description of Cathodic Protection. Cath- odic protection, as the name signifies, is the process by which an entire surface is transformed into a...The National Asaoeiation of Corrosion Enguler "I i ,.I-11 Standard RP-Ol-69, "Recommended Practice Por ront.ol ol." Ex - ternal Corrosion on
Space Tug Docking Study. Volume 1: Executive Summary
NASA Technical Reports Server (NTRS)
1976-01-01
Results of a detailed systems analysis of the entire rendezvous and docking operation to be performed by the all-up space tug are presented. Specific areas investigated include: generating of operational requirements and a data base of candidate operational techniques and subsystem mechanizations; selection and ranking of integrated system designs capable of meeting the requirements generated; and definition of this simulation/demonstration program required to select and prove the most effective manual, autonomous, and hybrid rendezvous and docking systems.
Lattice distortion in hcp rare gas solids
NASA Astrophysics Data System (ADS)
Grechnev, A.; Tretyak, S. M.; Freiman, Yu. A.
2010-04-01
The lattice distortion parameter δ ≡c/a-√8/3 has been calculated as a function of molar volume for the hcp phases of He, Ar, Kr, and Xe. Results from both semi-empirical potentials and density functional theory are presented. Our study shows that δ is negative for helium in the entire pressure range. For Ar, Kr, and Xe δ changes sign from negative to positive as the pressure increases, growing rapidly in magnitude at higher pressures.
An integrated study of earth resources in the state of California using remote sensing techniques
NASA Technical Reports Server (NTRS)
Colwell, R. N. (Principal Investigator)
1977-01-01
The author has identified the following significant results. The effects on estimates of monthly volume runoff were determined separately for each of the following parameters: precipitation, evapotranspiration, lower zone and upper zone tension water capacity, imperviousness of the watershed, and percent of the watershed occupied by riparian vegetation, streams, and lakes. The most sensitive and critical parameters were found to be precipitation during the entire year and springtime evapotranspiration.
MOD-5A wind turbine generator program design report: Volume 1: Executive Summary
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator covering work performed between July 1980 and June 1984 is discussed. The report is divided into four volumes: Volume 1 summarizes the entire MOD-5A program, Volume 2 discusses the conceptual and preliminary design phases, Volume 3 describes the final design of the MOD-5A, and Volume 4 contains the drawings and specifications developed for the final design. Volume 1, the Executive Summary, summarizes all phases of the MOD-5A program. The performance and cost of energy generated by the MOD-5A are presented. Each subsystem - the rotor, drivetrain, nacelle, tower and foundation, power generation, and control and instrumentation subsystems - is described briefly. The early phases of the MOD-5A program, during which the design was analyzed and optimized, and new technologies and materials were developed, are discussed. Manufacturing, quality assurance, and safety plans are presented. The volume concludes with an index of volumes 2 and 3.
The relationship between brain volumes and intelligence in bipolar disorder.
Vreeker, Annabel; Abramovic, Lucija; Boks, Marco P M; Verkooijen, Sanne; van Bergen, Annet H; Ophoff, Roel A; Kahn, René S; van Haren, Neeltje E M
2017-12-01
Bipolar disorder type-I (BD-I) patients show a lower Intelligence Quotient (IQ) and smaller brain volumes as compared with healthy controls. Considering that in healthy individuals lower IQ is related to smaller total brain volume, it is of interest to investigate whether IQ deficits in BD-I patients are related to smaller brain volumes and to what extent smaller brain volumes can explain differences between premorbid IQ estimates and IQ after a diagnosis of BD-I. Magnetic resonance imaging brain scans, IQ and premorbid IQ scores were obtained from 195 BDI patients and 160 controls. We studied the relationship of (global, cortical and subcortical) brain volumes with IQ and IQ change. Additionally, we investigated the relationship between childhood trauma, lithium- and antipsychotic use and IQ. Total brain volume and IQ were positively correlated in the entire sample. This correlation did not differ between patients and controls. Although brain volumes mediated the relationship between BD-I and IQ in part, the direct relationship between the diagnosis and IQ remained significant. Childhood trauma and use of lithium and antipsychotic medication did not affect the relationship between brain volumes and IQ. However, current lithium use was related to lower IQ in patients. Our data suggest a similar relationship between brain volume and IQ in BD-I patients and controls. Smaller brain volumes only partially explain IQ deficits in patients. Therefore, our findings indicate that in addition to brain volumes and lithium use other disease factors play a role in IQ deficits in BD-I patients. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
N'Djin, W. Apoutou; Mougenot, Charles; Kobelevskiy, Ilya; Ramsay, Elizabeth; Bronskill, Michael; Chopra, Rajiv
2012-11-01
Ultrasound thermal therapy of localized prostate cancer offers a minimally-invasive non-ionizing alternative [1-3] to surgery and radiotherapy. MRI-controlled transurethral ultrasound prostate therapy [4-6] has previously been investigated in a pilot human feasibility study [7], by treating a small sub-volume of prostate tissue. In this study, the feasibility of transurethral dual-frequency ultrasound focal therapy has been investigated in gel phantom. A database of pelvic anatomical models of human prostate cancer patients have been created using MR clinical images. The largest prostate boundary (47 cm3) was used to fabricate an anatomical gel phantom which included various MR characteristics to mimic prostate tissues, 4 localized tumors and surrounding prostate tissues. A 9-element transurethral ultrasound applicator working in dual-frequency mode (f = 4.6/14.5 MHz) was evaluated to heat: (i) the entire prostate volume (Full prostate treatment strategy), (ii) a prostate region restricted to tumors (Focal therapy). Acoustic power of each element and rotation rate of the device were adjusted in realtime based on MR-thermometry feedback control (nine thermal slices updated every 6.2s). Experiments have been performed using dual-frequency ultrasound exposures (surface Pmax: 20W.cm-2). (i) For full prostate heating, 7 elements of the device were used to cover the entire prostate length. The heating process was completed within 35 min. Ultrasound exposures at the fundamental frequency allowed full heating of the largest prostate radii (>18 mm), while exposures at the 3rd harmonic ensured homogeneous treatment of the smallest radii. Undertreated and overtreated regions represented respectively 2% and 17% of the prostate volume. (ii) For focal therapy, the target region was optimized to maintain safe regions in the prostate and to cover all tumor-mimics. Only 5 ultrasound elements were used to treat successfully all tumor-mimics within 26 min. Undertreated and overtreated regions each represented 7% of the prostate volume. MRI-guided transurethral ultrasound procedure enables full treatment and focal therapy in human prostate geometry. Prostate volume heating was fast compared to standard HIFU prostate treatments. Dual-frequency ultrasound exposures allowed optimal heat deposition in all prostate regions. The focal therapy strategy is promising as regard to safety and could contribute to enhance the post-treatment autonomy of the patient.
Non-invasive thermal IR detection of breast tumor development in vivo
NASA Astrophysics Data System (ADS)
Case, Jason R.; Young, Madison A.; Dréau, D.; Trammell, Susan R.
2015-03-01
Lumpectomy coupled with radiation therapy and/or chemotherapy comprises the treatment of breast cancer for many patients. We are developing an enhanced thermal IR imaging technique that can be used in real-time to guide tissue excision during a lumpectomy. This novel enhanced thermal imaging method is a combination of IR imaging (8- 10 μm) and selective heating of blood (~0.5 °C) relative to surrounding water-rich tissue using LED sources at low powers. Post-acquisition processing of these images highlights temporal changes in temperature and is sensitive to the presence of vascular structures. In this study, fluorescent and enhanced thermal imaging modalities were used to estimate breast cancer tumor volumes as a function of time in 19 murine subjects over a 30-day study period. Tumor volumes calculated from fluorescent imaging follow an exponential growth curve for the first 22 days of the study. Cell necrosis affected the tumor volume estimates based on the fluorescent images after Day 22. The tumor volumes estimated from enhanced thermal imaging show exponential growth over the entire study period. A strong correlation was found between tumor volumes estimated using fluorescent imaging and the enhanced IR images, indicating that enhanced thermal imaging is capable monitoring tumor growth. Further, the enhanced IR images reveal a corona of bright emission along the edges of the tumor masses. This novel IR technique could be used to estimate tumor margins in real-time during surgical procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westerhout, R.W.J.; Balk, R.H.P.; Meijer, R.
1997-08-01
A screen heater with a gas sweep was developed and applied to study the pyrolysis kinetics of low density polyethene (LDPE) and polypropene (PP) at temperatures ranging from 450 to 530 C. The aim of this study was to examine the applicability of screen heaters to measure these kinetics. On-line measurement of the rate of volatiles formation using a hydrocarbon analyzer was applied to enable the determination of the conversion rate over the entire conversion range on the basis of a single experiment. Another important feature of the screen heater used in this study is the possibility to measure pyrolysismore » kinetics under nearly isothermal conditions. The kinetic constants for LDPE and PP pyrolysis were determined, using a first order model to describe the conversion rate in the 70--90% conversion range and the random chain dissociation model for the entire conversion range. In addition to the experimental work two single particle models have been developed which both incorporate a mass and a (coupled) enthalpy balance, which were used to assess the influence of internal and external heat transfer processes on the pyrolysis process. The first model assumes a variable density and constant volume during the pyrolysis process, whereas the second model assumes a constant density and a variable volume. An important feature of these models is that they can accommodate kinetic models for which no analytical representation of the pyrolysis kinetics is available.« less
Warnakulasuriya, Samantha R; Davies, Simon J; Wilson, R Jonathan T; Yates, David R A
2016-11-01
This study aims to investigate if there is equivalence in volumes of fluid administered when intravenous fluid therapy is guided by Pleth Variability Index (PVI) compared to the established technology of esophageal Doppler in low-risk patients undergoing major colorectal surgery. Randomized controlled trial. Operating room. Forty low-risk patients undergoing elective colorectal surgery. Patients were monitored by esophageal Doppler and PVI probes and were randomized to have fluid therapy directed by using one of these technologies, with 250 mL boluses of colloid to maintain a maximal stroke volume, or a PVI of less than 14%. Absolute volumes of fluid volumes given intraoperatively were measured as were 24 hours fluid volumes. Perioperative measurements of lactate and base excess were recorded as were postoperative complications. There was no significant difference between PVI and esophageal Doppler groups in mean total fluid administered (1286 vs 1520 mL, P=.300) or mean intraoperative fluid balance (+839 v+1145 mL, P=.150). PVI offers an entirely non-invasive alternative for goal-directed fluid therapy in this group of patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Cognitive correlates of white matter lesion load and brain atrophy
Dong, Chuanhui; Nabizadeh, Nooshin; Caunca, Michelle; Cheung, Ying Kuen; Rundek, Tatjana; Elkind, Mitchell S.V.; DeCarli, Charles; Sacco, Ralph L.; Stern, Yaakov
2015-01-01
Objective: We investigated white matter lesion load and global and regional brain volumes in relation to domain-specific cognitive performance in the stroke-free Northern Manhattan Study (NOMAS) population. Methods: We quantified white matter hyperintensity volume (WMHV), total cerebral volume (TCV), and total lateral ventricular (TLV) volume, as well as hippocampal and cortical gray matter (GM) lobar volumes in a subgroup. We used general linear models to examine MRI markers in relation to domain-specific cognitive performance, adjusting for key covariates. Results: MRI and cognitive data were available for 1,163 participants (mean age 70 ± 9 years; 60% women; 66% Hispanic, 17% black, 15% white). Across the entire sample, those with greater WMHV had worse processing speed. Those with larger TLV volume did worse on episodic memory, processing speed, and semantic memory tasks, and TCV did not explain domain-specific variability in cognitive performance independent of other measures. Age was an effect modifier, and stratified analysis showed that TCV and WMHV explained variability in some domains above age 70. Smaller hippocampal volume was associated with worse performance across domains, even after adjusting for APOE ε4 and vascular risk factors, whereas smaller frontal lobe volumes were only associated with worse executive function. Conclusions: In this racially/ethnically diverse, community-based sample, white matter lesion load was inversely associated with cognitive performance, independent of brain atrophy. Lateral ventricular, hippocampal, and lobar GM volumes explained domain-specific variability in cognitive performance. PMID:26156514
2014-01-01
Aims Presenting a new method for direct, quantitative analysis of enamel surface. Measurement of adhesive remnants and enamel loss resulting from debonding molar tubes. Material and methods Buccal surfaces of fifteen extracted human molars were directly scanned with an optic blue-light 3D scanner to the nearest 2 μm. After 20 s etching molar tubes were bonded and after 24 h storing in 0.9% saline - debonded. Then 3D scanning was repeated. Superimposition and comparison were proceeded and shape alterations of the entire objects were analyzed using specialized computer software. Residual adhesive heights as well as enamel loss depths have been obtained for the entire buccal surfaces. Residual adhesive volume and enamel loss volume have been calculated for every tooth. Results The maximum height of adhesive remaining on enamel surface was 0.76 mm and the volume on particular teeth ranged from 0.047 mm3 to 4.16 mm3. The median adhesive remnant volume was 0.988 mm3. Mean depths of enamel loss for particular teeth ranged from 0.0076 mm to 0.0416 mm. Highest maximum depth of enamel loss was 0.207 mm. Median volume of enamel loss was 0.104 mm3 and maximum volume was 1.484 mm3. Conclusions Blue-light 3D scanning is able to provide direct precise scans of the enamel surface, which can be superimposed in order to calculate shape alterations. Debonding molar tubes leaves a certain amount of adhesive remnants on the enamel, however the interface fracture pattern varies for particular teeth and areas of enamel loss are present as well. PMID:25208969
Janiszewska-Olszowska, Joanna; Tandecka, Katarzyna; Szatkiewicz, Tomasz; Sporniak-Tutak, Katarzyna; Grocholewicz, Katarzyna
2014-09-10
Presenting a new method for direct, quantitative analysis of enamel surface. Measurement of adhesive remnants and enamel loss resulting from debonding molar tubes. Buccal surfaces of fifteen extracted human molars were directly scanned with an optic blue-light 3D scanner to the nearest 2 μm. After 20 s etching molar tubes were bonded and after 24 h storing in 0.9% saline - debonded. Then 3D scanning was repeated. Superimposition and comparison were proceeded and shape alterations of the entire objects were analyzed using specialized computer software. Residual adhesive heights as well as enamel loss depths have been obtained for the entire buccal surfaces. Residual adhesive volume and enamel loss volume have been calculated for every tooth. The maximum height of adhesive remaining on enamel surface was 0.76 mm and the volume on particular teeth ranged from 0.047 mm3 to 4.16 mm3. The median adhesive remnant volume was 0.988 mm3. Mean depths of enamel loss for particular teeth ranged from 0.0076 mm to 0.0416 mm. Highest maximum depth of enamel loss was 0.207 mm. Median volume of enamel loss was 0.104 mm3 and maximum volume was 1.484 mm3. Blue-light 3D scanning is able to provide direct precise scans of the enamel surface, which can be superimposed in order to calculate shape alterations. Debonding molar tubes leaves a certain amount of adhesive remnants on the enamel, however the interface fracture pattern varies for particular teeth and areas of enamel loss are present as well.
Millimeter-wave automotive radars: the markets, technologies, and production costs
NASA Astrophysics Data System (ADS)
Raffaelli, Lamberto; Stewart, Earle
1995-01-01
This paper examines markets, competing technologies, and required production costs of 77 GHz automotive radars. These products will be offered to the market a few years from now and represent the largest opportunity ever offered to the millimeter-wave (MMW) industry. To succeed in this business, an entire industry, primarily focused in the past on expensive small volume military applications, has to be re-engineered to successfully design and manufacture low cost, large volume parts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1980-06-01
These proceedings document the presentations given at the Second Environmental Control Symposium. Symposium presentations highlighted environmental control activities which span the entire DOE. Volume I contains papers relating to coal preparation, oil shales, coal combustion, advanced coal utilization (fluidized bed combustion, MHD generators, OCGT, fuel cells), coal gasification, coal liquefaction, and fossil resource extraction (enhanced recovery). Separate abstracts for individual papers are prepared for inclusion in the Energy Data Base. (DMC)
Constructal vascularized structures
NASA Astrophysics Data System (ADS)
Cetkin, Erdal
2015-06-01
Smart features such as self-healing and selfcooling require bathing the entire volume with a coolant or/and healing agent. Bathing the entire volume is an example of point to area (or volume) flows. Point to area flows cover all the distributing and collecting kinds of flows, i.e. inhaling and exhaling, mining, river deltas, energy distribution, distribution of products on the landscape and so on. The flow resistances of a point to area flow can be decreased by changing the design with the guidance of the constructal law, which is the law of the design evolution in time. In this paper, how the flow resistances (heat, fluid and stress) can be decreased by using the constructal law is shown with examples. First, the validity of two assumptions is surveyed: using temperature independent Hess-Murray rule and using constant diameter ducts where the duct discharges fluid along its edge. Then, point to area types of flows are explained by illustrating the results of two examples: fluid networks and heating an area. Last, how the structures should be vascularized for cooling and mechanical strength is documented. This paper shows that flow resistances can be decreased by morphing the shape freely without any restrictions or generic algorithms.
3D Convolutional Neural Network for Automatic Detection of Lung Nodules in Chest CT.
Hamidian, Sardar; Sahiner, Berkman; Petrick, Nicholas; Pezeshk, Aria
2017-01-01
Deep convolutional neural networks (CNNs) form the backbone of many state-of-the-art computer vision systems for classification and segmentation of 2D images. The same principles and architectures can be extended to three dimensions to obtain 3D CNNs that are suitable for volumetric data such as CT scans. In this work, we train a 3D CNN for automatic detection of pulmonary nodules in chest CT images using volumes of interest extracted from the LIDC dataset. We then convert the 3D CNN which has a fixed field of view to a 3D fully convolutional network (FCN) which can generate the score map for the entire volume efficiently in a single pass. Compared to the sliding window approach for applying a CNN across the entire input volume, the FCN leads to a nearly 800-fold speed-up, and thereby fast generation of output scores for a single case. This screening FCN is used to generate difficult negative examples that are used to train a new discriminant CNN. The overall system consists of the screening FCN for fast generation of candidate regions of interest, followed by the discrimination CNN.
3D convolutional neural network for automatic detection of lung nodules in chest CT
NASA Astrophysics Data System (ADS)
Hamidian, Sardar; Sahiner, Berkman; Petrick, Nicholas; Pezeshk, Aria
2017-03-01
Deep convolutional neural networks (CNNs) form the backbone of many state-of-the-art computer vision systems for classification and segmentation of 2D images. The same principles and architectures can be extended to three dimensions to obtain 3D CNNs that are suitable for volumetric data such as CT scans. In this work, we train a 3D CNN for automatic detection of pulmonary nodules in chest CT images using volumes of interest extracted from the LIDC dataset. We then convert the 3D CNN which has a fixed field of view to a 3D fully convolutional network (FCN) which can generate the score map for the entire volume efficiently in a single pass. Compared to the sliding window approach for applying a CNN across the entire input volume, the FCN leads to a nearly 800-fold speed-up, and thereby fast generation of output scores for a single case. This screening FCN is used to generate difficult negative examples that are used to train a new discriminant CNN. The overall system consists of the screening FCN for fast generation of candidate regions of interest, followed by the discrimination CNN.
A PDE approach for quantifying and visualizing tumor progression and regression
NASA Astrophysics Data System (ADS)
Sintay, Benjamin J.; Bourland, J. Daniel
2009-02-01
Quantification of changes in tumor shape and size allows physicians the ability to determine the effectiveness of various treatment options, adapt treatment, predict outcome, and map potential problem sites. Conventional methods are often based on metrics such as volume, diameter, or maximum cross sectional area. This work seeks to improve the visualization and analysis of tumor changes by simultaneously analyzing changes in the entire tumor volume. This method utilizes an elliptic partial differential equation (PDE) to provide a roadmap of boundary displacement that does not suffer from the discontinuities associated with other measures such as Euclidean distance. Streamline pathways defined by Laplace's equation (a commonly used PDE) are used to track tumor progression and regression at the tumor boundary. Laplace's equation is particularly useful because it provides a smooth, continuous solution that can be evaluated with sub-pixel precision on variable grid sizes. Several metrics are demonstrated including maximum, average, and total regression and progression. This method provides many advantages over conventional means of quantifying change in tumor shape because it is observer independent, stable for highly unusual geometries, and provides an analysis of the entire three-dimensional tumor volume.
A coarse-to-fine approach for pericardial effusion localization and segmentation in chest CT scans
NASA Astrophysics Data System (ADS)
Liu, Jiamin; Chellamuthu, Karthik; Lu, Le; Bagheri, Mohammadhadi; Summers, Ronald M.
2018-02-01
Pericardial effusion on CT scans demonstrates very high shape and volume variability and very low contrast to adjacent structures. This inhibits traditional automated segmentation methods from achieving high accuracies. Deep neural networks have been widely used for image segmentation in CT scans. In this work, we present a two-stage method for pericardial effusion localization and segmentation. For the first step, we localize the pericardial area from the entire CT volume, providing a reliable bounding box for the more refined segmentation step. A coarse-scaled holistically-nested convolutional networks (HNN) model is trained on entire CT volume. The resulting HNN per-pixel probability maps are then threshold to produce a bounding box covering the pericardial area. For the second step, a fine-scaled HNN model is trained only on the bounding box region for effusion segmentation to reduce the background distraction. Quantitative evaluation is performed on a dataset of 25 CT scans of patient (1206 images) with pericardial effusion. The segmentation accuracy of our two-stage method, measured by Dice Similarity Coefficient (DSC), is 75.59+/-12.04%, which is significantly better than the segmentation accuracy (62.74+/-15.20%) of only using the coarse-scaled HNN model.
The colour of an avifauna: A quantitative analysis of the colour of Australian birds
Delhey, Kaspar
2015-01-01
Animal coloration is a poorly-understood aspect of phenotypic variability. Here I expand initial studies of the colour gamut of birds by providing the first quantitative description of the colour variation of an entire avifauna: Australian landbirds (555 species). The colour of Australian birds occupies a small fraction (19%) of the entire possible colour space and colour variation is extremely uneven. Most colours are unsaturated, concentrated in the centre of colour space and based on the deposition of melanins. Other mechanisms of colour production are less common but account for larger portions of colour space and for most saturated colours. Male colours occupy 45–25% more colour space than female colours, indicating that sexual dichromatism translates into a broader range of male colours. Male-exclusive colours are often saturated, at the edge of chromatic space, and have most likely evolved for signalling. While most clades of birds occupy expected or lower-than-expected colour volumes, parrots and cockatoos (Order Psittaciformes) occupy a much larger volume than expected. This uneven distribution of colour variation across mechanisms of colour production, sexes and clades is probably shared by avifaunas in other parts of the world, but this remains to be tested with comparable data. PMID:26679370
Atrophied Brain Lesion Volume: A New Imaging Biomarker in Multiple Sclerosis.
Dwyer, Michael G; Bergsland, Niels; Ramasamy, Deepa P; Jakimovski, Dejan; Weinstock-Guttman, Bianca; Zivadinov, Robert
2018-06-01
Lesion accrual in multiple sclerosis (MS) is an important and clinically relevant measure, used extensively as an imaging trial endpoint. However, lesions may also shrink or disappear entirely due to atrophy. Although generally ignored or treated as a nuisance, this phenomenon may actually be an important stand-alone imaging biomarker. Therefore, we investigated the rate of brain lesion loss due to atrophy (atrophied lesion volume) in MS subtypes compared to baseline lesion volume and to new and enlarging lesion volumes, and evaluated the independent predictive value of this phenomenon for clinical disability. A total of 192 patients (18 clinically isolated syndrome, 126 relapsing-remitting MS, and 48 progressive) received 3T magnetic resonance imaging at baseline and 5 years. Lesions were quantified at baseline, and new/enlarging lesion volumes were calculated over the study interval. Atrophied lesion volume was calculated by combining baseline lesion masks with follow-up SIENAX-derived cerebrospinal fluid partial volume maps. Measures were compared between disease subgroups, and correlations with disability change (Expanded Disability Status Scale [EDSS]) were evaluated. Hierarchical regression was employed to determine the unique additive value of atrophied lesion volume. Atrophied lesion volume was different between MS subtypes (P = .02), and exceeded new lesion volume accumulation in progressive MS (298.1 vs. 75.5 mm 3 ). Atrophied lesion volume was the only significant correlate of EDSS change (r = .192 relapsing, r = .317 progressive, P < .05), and explained significant additional variance when controlling for brain atrophy and new/enlarging lesion volume (R 2 .092 vs. .045, P = .003). Atrophied lesion volume is a unique and clinically relevant imaging marker in MS, with particular promise in progressive MS. Copyright © 2018 by the American Society of Neuroimaging.
Chalian, Hamid; Seyal, Adeel Rahim; Rezai, Pedram; Töre, Hüseyin Gürkan; Miller, Frank H; Bentrem, David J; Yaghmai, Vahid
2014-01-10
The accuracy for determining pancreatic cyst volume with commonly used spherical and ellipsoid methods is unknown. The role of CT volumetry in volumetric assessment of pancreatic cysts needs to be explored. To compare volumes of the pancreatic cysts by CT volumetry, spherical and ellipsoid methods and determine their accuracy by correlating with actual volume as determined by EUS-guided aspiration. Setting This is a retrospective analysis performed at a tertiary care center. Patients Seventy-eight pathologically proven pancreatic cysts evaluated with CT and endoscopic ultrasound (EUS) were included. Design The volume of fourteen cysts that had been fully aspirated by EUS was compared to CT volumetry and the routinely used methods (ellipsoid and spherical volume). Two independent observers measured all cysts using commercially available software to evaluate inter-observer reproducibility for CT volumetry. The volume of pancreatic cysts as determined by various methods was compared using repeated measures analysis of variance. Bland-Altman plot and intraclass correlation coefficient were used to determine mean difference and correlation between observers and methods. The error was calculated as the percentage of the difference between the CT estimated volumes and the aspirated volume divided by the aspirated one. CT volumetry was comparable to aspirated volume (P=0.396) with very high intraclass correlation (r=0.891, P<0.001) and small mean difference (0.22 mL) and error (8.1%). Mean difference with aspirated volume and error were larger for ellipsoid (0.89 mL, 30.4%; P=0.024) and spherical (1.73 mL, 55.5%; P=0.004) volumes than CT volumetry. There was excellent inter-observer correlation in volumetry of the entire cohort (r=0.997, P<0.001). CT volumetry is accurate and reproducible. Ellipsoid and spherical volume overestimate the true volume of pancreatic cysts.
Commencement Bay Study. Volume VII. Sediments, Noise, Climate, and Air Quality, Aesthetics, Birds.
1981-12-31
Island (Carpenter et al. 1978). While the arsenic found in sediments near the smelter is almost entirely contained in slag (bulk and particles) and is...indicates slag in a freshwater, low pH environment does leach both arsenic and other selected heavy metals. See the EIS documents for the proposed ASARCO...flood protection to the industrial section of Tacoma through the channelization of the river, and the construction of levees and revetments (U.S. Army
Feasibility study for a numerical aerodynamic simulation facility. Volume 1
NASA Technical Reports Server (NTRS)
Lincoln, N. R.; Bergman, R. O.; Bonstrom, D. B.; Brinkman, T. W.; Chiu, S. H. J.; Green, S. S.; Hansen, S. D.; Klein, D. L.; Krohn, H. E.; Prow, R. P.
1979-01-01
A Numerical Aerodynamic Simulation Facility (NASF) was designed for the simulation of fluid flow around three-dimensional bodies, both in wind tunnel environments and in free space. The application of numerical simulation to this field of endeavor promised to yield economies in aerodynamic and aircraft body designs. A model for a NASF/FMP (Flow Model Processor) ensemble using a possible approach to meeting NASF goals is presented. The computer hardware and software are presented, along with the entire design and performance analysis and evaluation.
1976-12-01
System * 4. Fringe Benefits 5. Government Incurred Costs 6. Military Compensatioh Item 7. Military Equivalent Salary 114. Military Salary System 9. Non ...compensation whereby the military equivalent salary is paid entirely in cash and is fully taxable. 9. Non -Compensation Benefit a. An advantage to a service...other circumstances, the rate is 50 p daily. o Disturbance Allowance. The Disturbance Alowance is a non -taxable allowance designed to help pay for the
The treatment of extensive scalp lesions combining electrons with intensity-modulated photons.
Chan, Maria F; Song, Yulin; Burman, Chandra; Chui, Chen S; Schupak, Karen
2006-01-01
This study was to investigate the feasibility and potential benefits of combining electrons with intensity modulated photons (IMRT+e) for patients with extensive scalp lesions. A case of a patient with an extensive scalp lesion, in which the target volume covered the entire front half of the scalp, is presented. This approach incorporated the electron dose into the inverse treatment planning optimization. The resulting doses to the planning target volume (PTV) and relevant critical structures were compared. Thermoluminescent dosimeters (TLD), diodes, and GAFCHROMIC EBT films were used to verify the accuracy of the techniques. The IMRT+e plan produced a superior dose distribution to the patient as compared to the IMRT plan in terms of reduction of the dose to the brain with the same dose conformity and homogeneity in the target volumes. This study showed that IMRT+e is a viable treatment modality for extensive scalp lesions patients. It provides a feasible alternative to existing treatment techniques, resulting in improved homogeneity of dose to the PTV compared to conventional electron techniques and a decrease in dose to the brain compared to photon IMRT alone.
The Regionalization of Lumbar Spine Procedures in New York State: A 10-Year Analysis.
Jancuska, Jeffrey; Adrados, Murillo; Hutzler, Lorraine; Bosco, Joseph
2016-01-01
A retrospective review of an administrative database. The purpose of this study is to determine the current extent of regionalization by mapping lumbar spine procedures according to hospital and patient zip code, as well as examine the rate of growth of lumbar spine procedures performed at high-, medium-, and low-volume institutions in New York State. The association between hospital and spine surgeon volume and improved patient outcomes is well established. There is no study investigating the actual process of patient migration to high-volume hospitals. New York Statewide Planning and Research Cooperative System (SPARCS) administrative data were used to identify 228,695 lumbar spine surgery patients from 2005 to 2014. The data included the patients' zip code, hospital of operation, and year of discharge. The volume of lumbar spine surgery in New York State was mapped according to patient and hospital 3-digit zip code. New York State hospitals were categorized as low, medium, and high volume and descriptive statistics were used to determine trends in changes in hospital volume. Lumbar spine surgery recipients are widely distributed throughout the state. Procedures are regionalized on a select few metropolitan centers. The total number of procedures grew 2.5% over the entire 10-year-period. High-volume hospital caseload increased 50%, from 7253 procedures in 2005 to 10,915 procedures in 2014. The number of procedures at medium and low-volume hospitals decreased 30% and 13%, respectively. Despite any concerted effort aimed at moving orthopedic patients to high-volume hospitals, migration to high-volume centers occurred. Public interest in quality outcomes and cost, as well as financial incentives among medical centers to increase market share, potentially influence the migration of patients to high-volume centers. Further regionalization has the potential to exacerbate the current level of disparities among patient populations at low and high-volume hospitals. 3.
A Comparative Study of Pituitary Volume Variations in MRI in Acute Onset of Psychiatric Conditions.
Soni, Brijesh Kumar; Joish, Upendra Kumar; Sahni, Hirdesh; George, Raju A; Sivasankar, Rajeev; Aggarwal, Rohit
2017-02-01
The growing belief that endocrine abnormalities may underlie many mental conditions has led to increased use of imaging and hormonal assays in patients attending to psychiatric OPDs. People who are in an acute phase of a psychiatric disorder show Hypothalamic Pituitary Adrenal (HPA) axis hyperactivity, but the precise underlying central mechanisms are unclear. To assess the pituitary gland volume variations in patients presenting with new onset acute psychiatric illness in comparison with age and gender matched controls by using MRI. The study included 50 patients, with symptoms of acute psychiatric illness presenting within one month of onset of illness and 50 age and gender matched healthy controls. Both patients and controls were made to undergo MRI of the Brain. A 0.9 mm slices of entire brain were obtained by 3 dimensional T1 weighted sequence. Pituitary gland was traced in all sagittal slices. Anterior pituitary and posterior pituitary bright spot were measured separately in each slice. Volume of the pituitary (in cubic centimetre- cm 3 ) was calculated by summing areas. Significance of variations in pituitary gland volumes was compared between the cases and controls using Analysis of Covariance (ANOVA). There were significantly larger pituitary gland volumes in the cases than the controls, irrespective of psychiatric diagnosis (ANOVA, f=15.56; p=0.0002). Pituitary volumes in cases were 15.36% (0.73 cm 3 ) higher than in controls. There is a strong likelihood of HPA axis overactivity during initial phase of all mental disorders along with increased pituitary gland volumes. Further studies including hormonal assays and correlation with imaging are likely to provide further insight into neuroanatomical and pathological basis of psychiatric disorders.
Effects of air vessel on water hammer in high-head pumping station
NASA Astrophysics Data System (ADS)
Wang, L.; Wang, F. J.; Zou, Z. C.; Li, X. N.; Zhang, J. C.
2013-12-01
Effects of air vessel on water hammer process in a pumping station with high-head were analyzed by using the characteristics method. The results show that the air vessel volume is the key parameter that determines the protective effect on water hammer pressure. The maximum pressure in the system declines with increasing air vessel volume. For a fixed volume of air vessel, the shape of air vessel and mounting style, such as horizontal or vertical mounting, have little effect on the water hammer. In order to obtain good protection effects, the position of air vessel should be close to the outlet of the pump. Generally, once the volume of air vessel is guaranteed, the water hammer of a entire pipeline is effectively controlled.
NASA Astrophysics Data System (ADS)
Roy, Mahendra Nath; Das, Rajesh Kumar; Chanda, Riju
2010-03-01
Densities and viscosities were measured for the binary mixtures of cyclohexylamine and cyclohexanone with butyl acetate, butanone, butylamine, tert-butylamine, and 2-butoxyethanol at 298.15 K over the entire composition range. From density data, the values of the excess molar volume ( V E) have been calculated. The experimental viscosity data were correlated by means of the equation of Grunberg-Nissan. The density and viscosity data have been analyzed in terms of some semiempirical viscosity models. The results are discussed in terms of molecular interactions and structural effects. The excess molar volume is found to be either negative or positive depending on the molecular interactions and the nature of the liquid mixtures and is discussed in terms of molecular interactions and structural changes.
Central florida phosphate industry. Volume II. background and alternatives assessment. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1978-11-01
The Central Florida Phosphate District encompasses an area of approximately 2000 square miles in Polk, Hillsborough, Manatee, Hardee, and DeSoto Counties, Florida. There are currently 17 potential new source mines in the district. This EIS assessed areawide and cumulative effects on the entire area and provides the basis for development of site specific EISs. The final EIS establishes a scenario of phosphate development which was determined to be as compatible as practicable with other desired and intended land uses in Central Florida. Volume II describes the Central Florida Phosphate Industry and the Natural and man-made environments of the study area.more » Several scenarios are presented as decision alternatives and primary and secondary effects are assessed and compared.« less
The Manhattan Project: Making the Atomic Bomb. 2010 edition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gosling, F. G.
This historical document is part of a planned 3-volume series. This volume, volume 1, provides a short history of the origins and development of the American atomic bomb program during World War II. Beginning with the scientific developments of the pre-war years, the monograph details the role of the United States government in conducting a secret, nationwide enterprise that took science from the laboratory and into combat with an entirely new type of weapon. The monograph concludes with a discussion of the immediate postwar period, the debate over the Atomic Energy Act of 1946, and the founding of the Atomicmore » Energy Commission.« less
Design, simulation, and optimization of an RGB polarization independent transmission volume hologram
NASA Astrophysics Data System (ADS)
Mahamat, Adoum Hassan
Volume phase holographic (VPH) gratings have been designed for use in many areas of science and technology such as optical communication, medical imaging, spectroscopy and astronomy. The goal of this dissertation is to design a volume phase holographic grating that provides diffraction efficiencies of at least 70% for the entire visible wavelengths and higher than 90% for red, green, and blue light when the incident light is unpolarized. First, the complete design, simulation and optimization of the volume hologram are presented. The optimization is done using a Monte Carlo analysis to solve for the index modulation needed to provide higher diffraction efficiencies. The solutions are determined by solving the diffraction efficiency equations determined by Kogelnik's two wave coupled-wave theory. The hologram is further optimized using the rigorous coupled-wave analysis to correct for effects of absorption omitted by Kogelnik's method. Second, the fabrication or recording process of the volume hologram is described in detail. The active region of the volume hologram is created by interference of two coherent beams within the thin film. Third, the experimental set up and measurement of some properties including the diffraction efficiencies of the volume hologram, and the thickness of the active region are conducted. Fourth, the polarimetric response of the volume hologram is investigated. The polarization study is developed to provide insight into the effect of the refractive index modulation onto the polarization state and diffraction efficiency of incident light.
Gerritsen, L; Kalpouzos, G; Westman, E; Simmons, A; Wahlund, L O; Bäckman, L; Fratiglioni, L; Wang, H X
2015-04-01
Psychosocial stress has been related to changes in the nervous system, with both adaptive and maladaptive consequences. The aim of this study was to examine the relationship of negative events experienced throughout the entire lifespan and hippocampal and amygdala volumes in older adults. In 466 non-demented old adults (age range 60-96 years, 58% female), hippocampal and amygdala volumes were segmented using Freesurfer. Negative life events and the age at which these events occurred were assessed by means of a structured questionnaire. Using generalized linear models, hippocampal and amygdala volumes were estimated with life events as independent variables. The statistical analyses were adjusted for age, gender, intracranial volume, lifestyle factors, cardiovascular risk factors, depressive symptoms, and cognitive functioning. Total number of negative life events and of late-life events, but not of early-life, early-adulthood, or middle-adulthood events, was related to larger amygdala volume. There were interactions of early-life events with age and gender. Participants who reported two or more early-life events had significantly smaller amygdala and hippocampal volumes with increasing age. Furthermore, smaller hippocampal volume was found in men who reported two or more early-life events, but not in women. These results suggest that the effect of negative life events on the brain depends on the time when the events occurred, with the strongest effects observed during the critical time periods of early and late life.
Chang, W-K; Chao, Y-C; Mcclave, S-A; Yeh, M-K
2005-10-01
Gastric residual volumes are widely used to evaluate gastric emptying for patients receiving enteral feeding, but controversy exists about what constitutes gastric residual volume. We have developed a method by using refractometer and derived mathematical equations to calculate the formula concentration, total residual volume (TRV), and formula volume. In this study, we like to validate these mathematical equations before they can be implemented for clinical patient care. Four dietary formulas were evaluated in two consecutive validation experiments. Firstly, dietary formula volume of 50, 100, 200, and 400 ml were diluted with 50 ml water, and then the Brix value (BV) was measured by the refractometer. Secondly, 50 ml of water, then 100 ml of dietary formula were infused into a beaker, and followed by the BV measurement. After this, 50 ml of water was infused and followed by the second BV measurement. The entire procedure of infusing of dietary formula (100 ml) and waster (50 ml) was repeated twice and followed by the BV measurement. The formula contents (formula concentration, TRV, and formula volume) were calculated by mathematical equations. The calculated formula concentrations, TRVs, and formula volumes measured from mathematic equations were strongly close to the true values in the first and second validation experiments (R2>0.98, P<0.001). Refractometer and the derived mathematical equations may be used to accurately measure the formula concentration, TRV, and formula volume and served as a tool to monitor gastric emptying for patients receiving enteral feeding.
3D Imaging of Nanoparticle Distribution in Biological Tissue by Laser-Induced Breakdown Spectroscopy
NASA Astrophysics Data System (ADS)
Gimenez, Y.; Busser, B.; Trichard, F.; Kulesza, A.; Laurent, J. M.; Zaun, V.; Lux, F.; Benoit, J. M.; Panczer, G.; Dugourd, P.; Tillement, O.; Pelascini, F.; Sancey, L.; Motto-Ros, V.
2016-07-01
Nanomaterials represent a rapidly expanding area of research with huge potential for future medical applications. Nanotechnology indeed promises to revolutionize diagnostics, drug delivery, gene therapy, and many other areas of research. For any biological investigation involving nanomaterials, it is crucial to study the behavior of such nano-objects within tissues to evaluate both their efficacy and their toxicity. Here, we provide the first account of 3D label-free nanoparticle imaging at the entire-organ scale. The technology used is known as laser-induced breakdown spectroscopy (LIBS) and possesses several advantages such as speed of operation, ease of use and full compatibility with optical microscopy. We then used two different but complementary approaches to achieve 3D elemental imaging with LIBS: a volume reconstruction of a sliced organ and in-depth analysis. This proof-of-concept study demonstrates the quantitative imaging of both endogenous and exogenous elements within entire organs and paves the way for innumerable applications.
Gimenez, Y; Busser, B; Trichard, F; Kulesza, A; Laurent, J M; Zaun, V; Lux, F; Benoit, J M; Panczer, G; Dugourd, P; Tillement, O; Pelascini, F; Sancey, L; Motto-Ros, V
2016-07-20
Nanomaterials represent a rapidly expanding area of research with huge potential for future medical applications. Nanotechnology indeed promises to revolutionize diagnostics, drug delivery, gene therapy, and many other areas of research. For any biological investigation involving nanomaterials, it is crucial to study the behavior of such nano-objects within tissues to evaluate both their efficacy and their toxicity. Here, we provide the first account of 3D label-free nanoparticle imaging at the entire-organ scale. The technology used is known as laser-induced breakdown spectroscopy (LIBS) and possesses several advantages such as speed of operation, ease of use and full compatibility with optical microscopy. We then used two different but complementary approaches to achieve 3D elemental imaging with LIBS: a volume reconstruction of a sliced organ and in-depth analysis. This proof-of-concept study demonstrates the quantitative imaging of both endogenous and exogenous elements within entire organs and paves the way for innumerable applications.
3D Imaging of Nanoparticle Distribution in Biological Tissue by Laser-Induced Breakdown Spectroscopy
Gimenez, Y.; Busser, B.; Trichard, F.; Kulesza, A.; Laurent, J. M.; Zaun, V.; Lux, F.; Benoit, J. M.; Panczer, G.; Dugourd, P.; Tillement, O.; Pelascini, F.; Sancey, L.; Motto-Ros, V.
2016-01-01
Nanomaterials represent a rapidly expanding area of research with huge potential for future medical applications. Nanotechnology indeed promises to revolutionize diagnostics, drug delivery, gene therapy, and many other areas of research. For any biological investigation involving nanomaterials, it is crucial to study the behavior of such nano-objects within tissues to evaluate both their efficacy and their toxicity. Here, we provide the first account of 3D label-free nanoparticle imaging at the entire-organ scale. The technology used is known as laser-induced breakdown spectroscopy (LIBS) and possesses several advantages such as speed of operation, ease of use and full compatibility with optical microscopy. We then used two different but complementary approaches to achieve 3D elemental imaging with LIBS: a volume reconstruction of a sliced organ and in-depth analysis. This proof-of-concept study demonstrates the quantitative imaging of both endogenous and exogenous elements within entire organs and paves the way for innumerable applications. PMID:27435424
NASA Technical Reports Server (NTRS)
Sitges, Marta; Jones, Michael; Shiota, Takahiro; Qin, Jian Xin; Tsujino, Hiroyuki; Bauer, Fabrice; Kim, Yong Jin; Agler, Deborah A.; Cardon, Lisa A.; Zetts, Arthur D.;
2003-01-01
BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.
Dalwani, Manish S; McMahon, Mary Agnes; Mikulich-Gilbertson, Susan K; Young, Susan E; Regner, Michael F; Raymond, Kristen M; McWilliams, Shannon K; Banich, Marie T; Tanabe, Jody L; Crowley, Thomas J; Sakai, Joseph T
2015-01-01
Structural neuroimaging studies have demonstrated lower regional gray matter volume in adolescents with severe substance and conduct problems. These research studies, including ours, have generally focused on male-only or mixed-sex samples of adolescents with conduct and/or substance problems. Here we compare gray matter volume between female adolescents with severe substance and conduct problems and female healthy controls of similar ages. Female adolescents with severe substance and conduct problems will show significantly less gray matter volume in frontal regions critical to inhibition (i.e. dorsolateral prefrontal cortex and ventrolateral prefrontal cortex), conflict processing (i.e., anterior cingulate), valuation of expected outcomes (i.e., medial orbitofrontal cortex) and the dopamine reward system (i.e. striatum). We conducted whole-brain voxel-based morphometric comparison of structural MR images of 22 patients (14-18 years) with severe substance and conduct problems and 21 controls of similar age using statistical parametric mapping (SPM) and voxel-based morphometric (VBM8) toolbox. We tested group differences in regional gray matter volume with analyses of covariance, adjusting for age and IQ at p<0.05, corrected for multiple comparisons at whole-brain cluster-level threshold. Female adolescents with severe substance and conduct problems compared to controls showed significantly less gray matter volume in right dorsolateral prefrontal cortex, left ventrolateral prefrontal cortex, medial orbitofrontal cortex, anterior cingulate, bilateral somatosensory cortex, left supramarginal gyrus, and bilateral angular gyrus. Considering the entire brain, patients had 9.5% less overall gray matter volume compared to controls. Female adolescents with severe substance and conduct problems in comparison to similarly aged female healthy controls showed substantially lower gray matter volume in brain regions involved in inhibition, conflict processing, valuation of outcomes, decision-making, reward, risk-taking, and rule-breaking antisocial behavior.
Henningsson, Per; Michaelis, Dirk; Nakata, Toshiyuki; Schanz, Daniel; Geisler, Reinhard; Schröder, Andreas; Bomphrey, Richard J.
2015-01-01
Particle image velocimetry has been the preferred experimental technique with which to study the aerodynamics of animal flight for over a decade. In that time, hardware has become more accessible and the software has progressed from the acquisition of planes through the flow field to the reconstruction of small volumetric measurements. Until now, it has not been possible to capture large volumes that incorporate the full wavelength of the aerodynamic track left behind during a complete wingbeat cycle. Here, we use a unique apparatus to acquire the first instantaneous wake volume of a flying animal's entire wingbeat. We confirm the presence of wake deformation behind desert locusts and quantify the effect of that deformation on estimates of aerodynamic force and the efficiency of lift generation. We present previously undescribed vortex wake phenomena, including entrainment around the wing-tip vortices of a set of secondary vortices borne of Kelvin–Helmholtz instability in the shear layer behind the flapping wings. PMID:26040598
Fenstermacher, Charles A.; Boyer, Keith
1986-01-01
A method and apparatus for obtaining uniform, high-energy, large-volume electrical discharges in the lasing medium of a gas laser whereby a high-energy electron beam is used as an external ionization source to ionize substantially the entire volume of the lasing medium which is then readily pumped by means of an applied potential less than the breakdown voltage of the medium. The method and apparatus are particularly useful in CO.sub.2 laser systems.
1951-01-01
by lowered cost, complexity, and flxed weight of the engine . An evaluation of the effect of throttling on specific impulse, as well as the way in... combustion chamber development. The throttling arrangement and the method of pump control are both closely with the design of the entire engine . As...the use of the rocket engine . For a complete coverage of these subjects, it is recommended that all volumes of this series be consulted
The Effects of Twitter Sentiment on Stock Price Returns.
Ranco, Gabriele; Aleksovski, Darko; Caldarelli, Guido; Grčar, Miha; Mozetič, Igor
2015-01-01
Social media are increasingly reflecting and influencing behavior of other complex systems. In this paper we investigate the relations between a well-known micro-blogging platform Twitter and financial markets. In particular, we consider, in a period of 15 months, the Twitter volume and sentiment about the 30 stock companies that form the Dow Jones Industrial Average (DJIA) index. We find a relatively low Pearson correlation and Granger causality between the corresponding time series over the entire time period. However, we find a significant dependence between the Twitter sentiment and abnormal returns during the peaks of Twitter volume. This is valid not only for the expected Twitter volume peaks (e.g., quarterly announcements), but also for peaks corresponding to less obvious events. We formalize the procedure by adapting the well-known "event study" from economics and finance to the analysis of Twitter data. The procedure allows to automatically identify events as Twitter volume peaks, to compute the prevailing sentiment (positive or negative) expressed in tweets at these peaks, and finally to apply the "event study" methodology to relate them to stock returns. We show that sentiment polarity of Twitter peaks implies the direction of cumulative abnormal returns. The amount of cumulative abnormal returns is relatively low (about 1-2%), but the dependence is statistically significant for several days after the events.
Konwar, Priyanka; Tiwari, S P; Gohain, M; Kumari, Kiran
2015-11-01
The aim of the present study was to assess the effect of dietary supplementation with different levels of protein on fecal egg counts and hematological parameters in goat kids with subclinical nematodosis under semi-intensive condition. 20 goat kids (3-5 months old with an average body weight of 8.90 kg) were randomly allocated to four groups: T1, served as a negative control, without receiving concentrate feed, and T2, T3, and T4 that received concentrate feed containing 16, 20, and 24% digestible crude protein, respectively. The experiment was carried out for 60 days. In this study, protein supplementation had a significant (p<0.05) effect on fecal egg counts even after 15 days; hemoglobin (Hb) (g/dl) after 45 days; total leukocyte count (10(3)/mm(3)) and total erythrocyte count (10(6)/mm(3)) after 30 days; packed cell volume (%), lymphocyte (%), and eosinophil (%) after 15 days of supplementation, whereas monocyte (%) and neutrophil (%) values were not significantly influenced by protein supplementation effect during the entire experiment. The values of mean corpuscular volume (fl) were affected significantly (p<0.05, p<0.01) due to protein supplementation after 30 days, mean corpuscular Hb (MCH) (pg) after 45 days, but MCH concentration (g/dl) was not significantly different among the experimental groups during the entire experiment. The dietary supplementation with different levels of protein significantly improved the hematological profiles and inhibited the nematodosis infection in the experimental goat kids.
Social brain volume is associated with in-degree social network size among older adults
2018-01-01
The social brain hypothesis proposes that large neocortex size evolved to support cognitively demanding social interactions. Accordingly, previous studies have observed that larger orbitofrontal and amygdala structures predict the size of an individual's social network. However, it remains uncertain how an individual's social connectedness reported by other people is associated with the social brain volume. In this study, we found that a greater in-degree network size, a measure of social ties identified by a subject's social connections rather than by the subject, significantly correlated with a larger regional volume of the orbitofrontal cortex, dorsomedial prefrontal cortex and lingual gyrus. By contrast, out-degree size, which is based on an individual's self-perceived connectedness, showed no associations. Meta-analytic reverse inference further revealed that regional volume pattern of in-degree size was specifically involved in social inference ability. These findings were possible because our dataset contained the social networks of an entire village, i.e. a global network. The results suggest that the in-degree aspect of social network size not only confirms the previously reported brain correlates of the social network but also shows an association in brain regions involved in the ability to infer other people's minds. This study provides insight into understanding how the social brain is uniquely associated with sociocentric measures derived from a global network. PMID:29367402
30 CFR 203.44 - What administrative steps must I take to use the royalty suspension volume?
Code of Federal Regulations, 2010 CFR
2010-07-01
... ultra-deep well on a lease that is located entirely in water more than 200 meters and less than 400 meters deep. (e) The MMS Regional Supervisor for Production and Development may extend the deadline for...
Reliability of psychophysiological responses across multiple motion sickness stimulation tests
NASA Technical Reports Server (NTRS)
Stout, C. S.; Toscano, W. B.; Cowings, P. S.
1995-01-01
Although there is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation, very little evidence exists that examines the reproducibility of autonomic responses within subjects during motion sickness stimulation. Our objectives were to examine the reliability of autonomic responses and symptom levels across five testing occasions using the (1) final minute of testing, (2) change in autonomic response and the change in symptom level, and (3) strength of the relationship between the change in symptom level and the change in autonomic responses across the entire motion sickness test. The results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and symptoms throughout the test duration are less stable across the tests. Finally, autonomic responses and symptom levels are significantly related across the entire motion sickness test.
Holographic rugate structures for x-ray optics applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jannson, T.; Savant, Gajendra.; Qiao, Yong.
1988-07-01
XUV Bragg Holographic Optical Elements (HOEs), based on a single-step volume holographic recording, have been proposed by Physical Optic Corporation (POC), as an entirely new approach to x-ray optics. Their theory, as well as the first experimental proof-of-concept, have been demonstrated in Phase 1 of the DOE program. During the first year (exactly, 8-month duration) of the on-going Phase 2, the high-efficiency XUV Lippmann holographic mirrors have been fabricated and their optical, physical, and material properties have been investigated over the entire XUV region (1--100nm). The XUV Bragg HOEs, based on dichromated gelatin (DCG) and on DCG/polymer grafts, have beenmore » recorded in the visible region (using an Innova Argo laser) and reconstructed using twelve XUV wavelengths. In addition, these phase high-resolution holographic materials have been shown to be suitable to direct x-ray laser holographic recording (using Princeton's x-ray laser). The volume x-ray holographic recording will be realized within the second year of the program effort.« less
He, Guoxi; Liang, Yongtu; Li, Yansong; Wu, Mengyu; Sun, Liying; Xie, Cheng; Li, Feng
2017-06-15
The accidental leakage of long-distance pressurized oil pipelines is a major area of risk, capable of causing extensive damage to human health and environment. However, the complexity of the leaking process, with its complex boundary conditions, leads to difficulty in calculating the leakage volume. In this study, the leaking process is divided into 4 stages based on the strength of transient pressure. 3 models are established to calculate the leaking flowrate and volume. First, a negative pressure wave propagation attenuation model is applied to calculate the sizes of orifices. Second, a transient oil leaking model, consisting of continuity, momentum conservation, energy conservation and orifice flow equations, is built to calculate the leakage volume. Third, a steady-state oil leaking model is employed to calculate the leakage after valves and pumps shut down. Moreover, sensitive factors that affect the leak coefficient of orifices and volume are analyzed respectively to determine the most influential one. To validate the numerical simulation, two types of leakage test with different sizes of leakage holes were conducted from Sinopec product pipelines. More validations were carried out by applying commercial software to supplement the experimental insufficiency. Thus, the leaking process under different leaking conditions are described and analyzed. Copyright © 2017 Elsevier B.V. All rights reserved.
Queiroz, Polyane Mazucatto; Rovaris, Karla; Santaella, Gustavo Machado; Haiter-Neto, Francisco; Freitas, Deborah Queiroz
2017-01-01
To calculate root canal volume and surface area in microCT images, an image segmentation by selecting threshold values is required, which can be determined by visual or automatic methods. Visual determination is influenced by the operator's visual acuity, while the automatic method is done entirely by computer algorithms. To compare between visual and automatic segmentation, and to determine the influence of the operator's visual acuity on the reproducibility of root canal volume and area measurements. Images from 31 extracted human anterior teeth were scanned with a μCT scanner. Three experienced examiners performed visual image segmentation, and threshold values were recorded. Automatic segmentation was done using the "Automatic Threshold Tool" available in the dedicated software provided by the scanner's manufacturer. Volume and area measurements were performed using the threshold values determined both visually and automatically. The paired Student's t-test showed no significant difference between visual and automatic segmentation methods regarding root canal volume measurements (p=0.93) and root canal surface (p=0.79). Although visual and automatic segmentation methods can be used to determine the threshold and calculate root canal volume and surface, the automatic method may be the most suitable for ensuring the reproducibility of threshold determination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massager, Nicolas; Nissim, Ouzi; Delbrouck, Carine
2006-04-01
Purpose: To analyze the relationship between hearing preservation after gamma knife radiosurgery (GKR) for vestibular schwannoma (VS) and some volumetric and dosimetric parameters of the intracanalicular components of VS. Methods and Materials: This study included 82 patients with a VS treated by GKR; all patients had no NF2 disease, a Gardner-Robertson hearing class 1-4 before treatment, a marginal dose of 12 Gy, and a radiologic and audiologic follow-up {>=}1 year post-GKR. The volume of both the entire tumor and the intracanalicular part of the tumor and the mean and integrated dose of these two volumes were correlated to the auditorymore » outcomes of patients. Results: At last hearing follow-up, 52 patients had no hearing worsening, and 30 patients had an increase of {>=}1 class on Gardner-Robertson classification. We found that hearing preservation after GKR is significantly correlated with the intracanalicular tumor volume, as well as with the integrated dose delivered to the intracanalicular tumor volume. Conclusions: Some volumetric and dosimetric parameters of the intracanalicular part of the tumor influence hearing preservation after GKR of VS. Consequently, we advise the direct treatment of patients with preserved functional hearing and a VS including a small intracanalicular volume.« less
Morimoto, Naoki; Wani, Ryoji; Naglik, Carole; Klug, Christian
2015-01-01
Nautilus remains of great interest to palaeontologists after a long history of actualistic comparisons and speculations on aspects of the palaeoecology of fossil cephalopods, which are otherwise impossible to assess. Although a large amount of work has been dedicated to Nautilus ecology, conch geometry and volumes of shell parts and chambers have been studied less frequently. In addition, although the focus on volumetric analyses for ammonites has been increasing recently with the development of computed tomographic technology, the intraspecific variation of volumetric parameters has never been examined. To investigate the intraspecific variation of the phragmocone chamber volumes throughout ontogeny, 30 specimens of Recent Nautilus pompilius and two Middle Jurassic ammonites (Normannites mitis) were reconstructed using computed tomography and grinding tomography, respectively. Both of the ontogenetic growth trajectories from the two Normannites demonstrate logistic increase. However, a considerable difference in Normannites has been observed between their entire phragmocone volumes (cumulative chamber volumes), in spite of their similar morphology and size. Ontogenetic growth trajectories from Nautilus also show a high variation. Sexual dimorphism appears to contribute significantly to this variation. Finally, covariation between chamber widths and volumes was examined. The results illustrate the strategic difference in chamber construction between Nautilus and Normannites. The former genus persists to construct a certain conch shape, whereas the conch of the latter genus can change its shape flexibly under some constraints. PMID:26500816
Estimation of liquid volume fraction using ultrasound transit time spectroscopy
NASA Astrophysics Data System (ADS)
Al-Qahtani, Saeed M.; Langton, Christian M.
2016-12-01
It has recently been proposed that the propagation of an ultrasound wave through complex structures, consisting of two-materials of differing ultrasound velocity, may be considered as an array of parallel ‘sonic rays’, the transit time of each determined by their relative proportion; being a minimum (t min) in entire higher velocity material, and a maximum (t max) in entire lower velocity material. An ultrasound transit time spectrum (UTTS) describes the proportion of sonic rays at an individual transit time. It has previously been demonstrated that the solid volume fraction of a solid:liquid composite, specifically acrylic step-wedges immersed in water, may be reliably estimated from the UTTS. The aim of this research was to investigate the hypothesis that the volume fraction of a two-component liquid mixture, of unequal ultrasound velocity, may also be estimated by UTTS. A through-transmission technique incorporating two 1 MHz ultrasound transducers within a horizontally-aligned cylindrical tube-housing was utilised, the proportion of silicone oil to water being varied from 0% to 100%. The liquid volume fraction was estimated from the UTTS at each composition, the coefficient of determination (R 2%) being 98.9 ± 0.7%. The analysis incorporated a novel signal amplitude normalisation technique to compensate for absorption within the silicone oil. It is therefore envisaged that the parallel sonic ray concept and the derived UTTS may be further applied to the quantification of liquid mixture composition assessment.
NASA Astrophysics Data System (ADS)
Wang, Cuihuan; Kim, Leonard; Barnard, Nicola; Khan, Atif; Pierce, Mark C.
2016-02-01
Our long term goal is to develop a high-resolution imaging method for comprehensive assessment of tissue removed during lumpectomy procedures. By identifying regions of high-grade disease within the excised specimen, we aim to develop patient-specific post-operative radiation treatment regimens. We have assembled a benchtop spectral-domain optical coherence tomography (SD-OCT) system with 1320 nm center wavelength. Automated beam scanning enables "sub-volumes" spanning 5 mm x 5 mm x 2 mm (500 A-lines x 500 B-scans x 2 mm in depth) to be collected in under 15 seconds. A motorized sample positioning stage enables multiple sub-volumes to be acquired across an entire tissue specimen. Sub-volumes are rendered from individual B-scans in 3D Slicer software and en face (XY) images are extracted at specific depths. These images are then tiled together using MosaicJ software to produce a large area en face view (up to 40 mm x 25 mm). After OCT imaging, specimens were sectioned and stained with HE, allowing comparison between OCT image features and disease markers on histopathology. This manuscript describes the technical aspects of image acquisition and reconstruction, and reports initial qualitative comparison between large area en face OCT images and HE stained tissue sections. Future goals include developing image reconstruction algorithms for mapping an entire sample, and registering OCT image volumes with clinical CT and MRI images for post-operative treatment planning.
NASA Technical Reports Server (NTRS)
Anderson, J. E. (Principal Investigator)
1979-01-01
The net board foot volume (Scribner log rule) of the standing Ponderosa pine timber on the Defiance Unit of the Navajo Nation's forested land was estimated using a multistage forest volume inventory scheme with variable sample selection probabilities. The inventory designed to accomplish this task required that both LANDSAT MSS digital data and aircraft acquired data be used to locate one acre ground splits, which were subsequently visited by ground teams conducting detailed tree measurements using an optical dendrometer. The dendrometer measurements were then punched on computer input cards and were entered in a computer program developed by the U.S. Forest Service. The resulting individual tree volume estimates were then expanded through the use of a statistically defined equation to produce the volume estimate for the entire area which includes 192,026 acres and is approximately a 44% the total forested area of the Navajo Nation.
Montes, Luis Guillermo Almeida; Ricardo-Garcell, Josefina; De La Torre, Lázaro Barajas; Alcántara, Hugo Prado; García, Reyna Beatriz Martínez; Fernández-Bouzas, Antonio; Acosta, David Ávila
2010-01-01
Background Magnetic resonance imaging (MRI) studies have shown decreased caudate volumes in individuals with attention deficit hyperactivity disorder (ADHD). However, most of these studies have been carried out in male children. Very little research has been done in adults, and the results obtained in children are difficult to extrapolate to adults. We sought to compare the volume of the caudate of adults with ADHD with that of healthy controls; we also compared these volumes between men and women. Methods We performed an MRI scan on 20 adults with ADHD (10 men and 10 women) aged 25–35 years and 20 healthy controls matched by age and sex. We used voxel-based morphometry with the DARTEL algorithm for image analyses. We used the specifically designed Friederichsen, Almeida, Serrano, Cortes Test (FASCT) to measure the severity of ADHD; both the self-reported (FASCT-SR) and the observer (FASCT-O) versions were used. Results The statistical parametric map showed a smaller region with low grey matter volume and a smaller concentration of grey matter in this region of the right caudate in ADHD patients than in health controls, both in the entire sample and within each sex. There was a significant correlation between the volume of this region of the caudate with the number of DSM IV-TR criteria, as well as with the total scores and most of the factors of the FASCT-SR and FASCT-O scales. A separate correlation analysis by sex gave similar results. Limitations The study design was cross-sectional. Conclusion The region of the right caudate with low grey matter volume was smaller in adults with ADHD in both sexes and was correlated with ADHD severity. PMID:20569650
Furlanis, Giovanni; Ajčević, Miloš; Stragapede, Lara; Lugnan, Carlo; Ridolfi, Mariana; Caruso, Paola; Naccarato, Marcello; Ukmar, Maja; Manganotti, Paolo
2018-04-30
The National Institutes of Health Stroke Scale (NIHSS) is the most adopted stroke patients' evaluation tool in emergency settings to assess the severity of stroke and to determine the patients' eligibility for specific treatments. Computed tomography perfusion (CTP) is crucial to identify salvageable tissue that can benefit from the reperfusion treatment. The aim of this study is to identify the relation between the NIHSS scores and the hypoperfused volumes evaluated by CTP in patients with hyperacute ischemic stroke. This retrospective study was conducted on 105 patients with ischemic stroke who underwent NIHSS assessment and CTP in the hyperacute phase. Hypoperfused volume was evaluated by CTP maps processed with semi-automatic algorithm. An analysis was conducted to determine the degree of correlation between the NIHSS scores and the ischemic lesion volumes and to investigate the relation between the anterior and the posterior circulation strokes, as well as between the right and the left hemispheric strokes. A significant correlation was found between ischemic volume and NIHSS score at baseline (r = .82; P < .0001) in the entire cohort. A high NIHSS-volume correlation was identified in the anterior circulation stroke (r = .76; P < .0001); whereas, it was nonsignificant in the posterior circulation stroke. NIHSS score and volume correlated for the left and the right hemispheric strokes (r = .83 and .81; P < .0001), showing a slightly higher slope in the left. This study showed a strong correlation between the baseline NIHSS score and the ischemic volume estimated by CTP. We confirmed that NIHSS is a reliable predictor of perfusion deficits in acute ischemic stroke. CTP allows fast imaging assessment in the hyperacute phase. The results highlight the importance of these diagnostic tools in the assessment of stroke severity and in acute decision-making. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Mastalerz, Maria; Drobniak, A.; Strapoc, D.; Solano-Acosta, W.; Rupp, J.
2008-01-01
The Seelyville Coal Member of the Linton Formation (Pennsylvanian) in Indiana was studied to: 1) understand variations in pore characteristics within a coal seam at a single location and compare these variations with changes occurring between the same coal at different locations, 2) elaborate on the influence of mineral-matter and maceral composition on mesopore and micropore characteristics, and 3) discuss implications of these variations for coal bed gas content. The coal is high volatile bituminous rank with R0 ranging from 0.57% to 0.60%. BET specific surface areas (determined by nitrogen adsorption) of the coals samples studied range from 1.8 to 22.9??m2/g, BJH adsorption mesopore volumes from 0.0041 to 0.0339??cm3/g, and micropore volumes (determined by carbon dioxide adsorption) from 0.0315 to 0.0540??cm3/g. The coals that had the largest specific surface areas and largest mesopore volumes occur at the shallowest depths, whereas the smallest values for these two parameters occur in the deepest coals. Micropore volumes, in contrast, are not depth-dependent. In the coal samples examined for this study, mineral-matter content influenced both specific surface area as well as mesopore and micropore volumes. It is especially clear in the case of micropores, where an increase in mineral-matter content parallels the decrease of micropore volume of the coal. No obvious relationships were observed between the total vitrinite content and pore characteristics but, after splitting vitrinite into individual macerals, we see that collotelinite influences both meso- and micropore volume positively, whereas collodetrinite contributes to the reduction of mesopore and micropore volumes. There are large variations in gas content within a single coal at a single location. Because of this variability, the entire thickness of the coal must be desorbed in order to determine gas content reliably and to accurately calculate the level of gas saturation. ?? 2008 Elsevier B.V. All rights reserved.
Histogram analysis of T2*-based pharmacokinetic imaging in cerebral glioma grading.
Liu, Hua-Shan; Chiang, Shih-Wei; Chung, Hsiao-Wen; Tsai, Ping-Huei; Hsu, Fei-Ting; Cho, Nai-Yu; Wang, Chao-Ying; Chou, Ming-Chung; Chen, Cheng-Yu
2018-03-01
To investigate the feasibility of histogram analysis of the T2*-based permeability parameter volume transfer constant (K trans ) for glioma grading and to explore the diagnostic performance of the histogram analysis of K trans and blood plasma volume (v p ). We recruited 31 and 11 patients with high- and low-grade gliomas, respectively. The histogram parameters of K trans and v p , derived from the first-pass pharmacokinetic modeling based on the T2* dynamic susceptibility-weighted contrast-enhanced perfusion-weighted magnetic resonance imaging (T2* DSC-PW-MRI) from the entire tumor volume, were evaluated for differentiating glioma grades. Histogram parameters of K trans and v p showed significant differences between high- and low-grade gliomas and exhibited significant correlations with tumor grades. The mean K trans derived from the T2* DSC-PW-MRI had the highest sensitivity and specificity for differentiating high-grade gliomas from low-grade gliomas compared with other histogram parameters of K trans and v p . Histogram analysis of T2*-based pharmacokinetic imaging is useful for cerebral glioma grading. The histogram parameters of the entire tumor K trans measurement can provide increased accuracy with additional information regarding microvascular permeability changes for identifying high-grade brain tumors. Copyright © 2017 Elsevier B.V. All rights reserved.
Lava effusion rate definition and measurement: a review
Calvari, Sonia; Dehn, Jonathan; Harris, A.
2007-01-01
Measurement of effusion rate is a primary objective for studies that model lava flow and magma system dynamics, as well as for monitoring efforts during on-going eruptions. However, its exact definition remains a source of confusion, and problems occur when comparing volume flux values that are averaged over different time periods or spatial scales, or measured using different approaches. Thus our aims are to: (1) define effusion rate terminology; and (2) assess the various measurement methods and their results. We first distinguish between instantaneous effusion rate, and time-averaged discharge rate. Eruption rate is next defined as the total volume of lava emplaced since the beginning of the eruption divided by the time since the eruption began. The ultimate extension of this is mean output rate, this being the final volume of erupted lava divided by total eruption duration. Whether these values are total values, i.e. the flux feeding all flow units across the entire flow field, or local, i.e. the flux feeding a single active unit within a flow field across which many units are active, also needs to be specified. No approach is without its problems, and all can have large error (up to ∼50%). However, good agreement between diverse approaches shows that reliable estimates can be made if each approach is applied carefully and takes into account the caveats we detail here. There are three important factors to consider and state when measuring, giving or using an effusion rate. First, the time-period over which the value was averaged; second, whether the measurement applies to the entire active flow field, or a single lava flow within that field; and third, the measurement technique and its accompanying assumptions.
The Whole-Brain N-Acetylaspartate Correlates with Education in Normal Adults
Glodzik, Lidia; Wu, William E.; Babb, James S.; Achtnichts, Lutz; Amann, Michael; Sollberger, Marc; Monsch, Andreas U.; Gass, Achim; Gonen, Oded
2012-01-01
N-acetylaspartate (NAA) is an index of neuronal integrity. We hypothesized that in healthy subjects its whole brain concentration (WBNAA) may be related to formal educational attainment, a common proxy for cognitive reserve. To test this hypothesis 97 middle aged to elderly subjects (51–89 years old, 38% women) underwent brain MRI and non-localizing proton spectroscopy. Their WBNAA was obtained by dividing their whole-head NAA amount with the brain volume. Intracranial volume and fractional brain volume, a metric of brain atrophy, were also determined. Each subject’s educational attainment was the sum of their years of formal education. In the entire group higher education was associated with larger intracranial volume. The relationship between WBNAA and education was observed only in younger (51–70 years old) participants. In this group education explained 21% variance in WBNAA. More WBNAA was related to more years of formal education in adults and younger elders. Prospective studies can determine whether this relationship reflects a true advantage from years of training versus innate characteristic predisposing to higher achievements later in life. We offer that late life WBNAA may be more affected by other like factors acting at midlife and later. PMID:23177924
Kansa, Edward J.; Anderson, Brian L.; Wijesinghe, Ananda M.; Viani, Brian E.
1999-01-01
This invention provides a process to tremendously reduce the bulk volume of contaminants obtained from an effluent stream produced subsurface remediation. The chemicals used for the subsurface remediation are reclaimed for recycling to the remediation process. Additional reductions in contaminant bulk volume are achieved by the ultra-violet light destruction of halogenated hydrocarbons, and the complete oxidation of hydrophobic fuel hydrocarbons and hydrophilic hydrocarbons. The contaminated bulk volume will arise primarily from the disposal of the toxic metal ions. The entire process is modular, so if there are any technological breakthroughs in one or more of the component process modules, such modules can be readily replaced.
Vozarova, B; Weyer, C; Bogardus, C; Ravussin, E; Tataranni, P A
2002-06-01
Body temperature is a function of heat production and heat dissipation. Substantial interindividual variability has been reported in healthy humans. We hypothesized that Pima Indians, a population with a high prevalence of abdominal obesity, may have a lower surface area relative to volume, that is, lower radiating area, and therefore a higher body temperature compared to Caucasians. Body composition, including volume (hydrodensitometry), and oral temperature were assessed in 69 nondiabetic Caucasian [age, 30 +/- 7 years; body fat, 21 +/- 8% (mean +/- SD)] and 115 Pima Indian males [age, 27 +/- 6 years; body fat, 28 +/- 6%]. Surface area was estimated from height, weight, and waist circumference (Bouchard's equation). In 47 Pima Indians, measures of insulin sensitivity (M, hyperinsulinemic euglycemic clamp) were available. Compared to Caucasians, Pima Indians had a higher oral temperature [36.4 +/- 0.3 degrees C vs. 36.3 +/- 0.3 degrees C (mean +/- SD), p < 0.04] and lower surface area relative to volume (2.19 +/- 0.05 vs. 2.23 +/- 0.26 m(2), p < 0.0001). Surface area relative to volume was negatively correlated with oral temperature (r = -0.14, p < 0.05), but in a multiple linear regression model it did not entirely explain the ethnic difference in oral temperature. Oral temperature was inversely correlated with M (r = -0.28, p < 0.05). Conclusions-Pima Indians have higher oral temperature and lower surface area relative to volume than Caucasians. The ethnic difference in temperature does not seem to be entirely explained by differences in body composition and body shape. Interestingly, higher oral temperature was associated with insulin resistance, a risk factor for type 2 diabetes.
LACIE: Wheat yield models for the United States, revision A
NASA Technical Reports Server (NTRS)
1977-01-01
For abstract, see volume 1 N77-30577. The enclosed maps indicate the areal coverage of the various models for spring (durum and other spring) and winter wheat. The given regions are the combination of several climatic divisions and many times comprise an entire state.
40 CFR 62.14351 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... volume design capacity of the landfill by either horizontal or vertical expansion based on its permitted... construction on the horizontal or vertical expansion. Municipal solid waste landfill or MSW landfill means an entire disposal facility in a contiguous geographical space where household waste is placed in or on land...
40 CFR 62.14351 - Definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... volume design capacity of the landfill by either horizontal or vertical expansion based on its permitted... construction on the horizontal or vertical expansion. Municipal solid waste landfill or MSW landfill means an entire disposal facility in a contiguous geographical space where household waste is placed in or on land...
DOT National Transportation Integrated Search
2016-06-30
This research developed advanced type 2 safety performance functions (SPF) for roadway segments, intersections and ramps on the entire Caltrans network. The advanced type 2 SPFs included geometrics, traffic volume and hierarchical random effects, whi...
Overcoming the Practical Barriers to Spinal Cord Cell Transplantation for ALS
2014-10-01
should not be neglected. Moreover, escalating numbers and volumes of injections seem to be associated with lack of accuracy and reflux . At the same...investigations of intraspinal stem cell therapies are underway for a range of neurological diseases . Originally considered entirely immuno-privileged, the
Hydrologic modeling of two glaciated watersheds in Northeast Pennsylvania
Srinivasan, M.S.; Hamlett, J.M.; Day, R.L.; Sams, J.I.; Petersen, G.W.
1998-01-01
A hydrologic modeling study, using the Hydrologic Simulation Program - FORTRAN (HSPF), was conducted in two glaciated watersheds, Purdy Creek and Ariel Creek in northeastern Pennsylvania. Both watersheds have wetlands and poorly drained soils due to low hydraulic conductivity and presence of fragipans. The HSPF model was calibrated in the Purdy Creek watershed and verified in the Ariel Creek watershed for June 1992 to December 1993 period. In Purdy Creek, the total volume of observed streamflow during the entire simulation period was 13.36 x 106 m3 and the simulated streamflow volume was 13.82 x 106 m3 (5 percent difference). For the verification simulation in Ariel Creek, the difference between the total observed and simulated flow volumes was 17 percent. Simulated peak flow discharges were within two hours of the observed for 30 of 46 peak flow events (discharge greater than 0.1 m3/sec) in Purdy Creek and 27 of 53 events in Ariel Creek. For 22 of the 46 events in Purdy Creek and 24 of 53 in Ariel Creek, the differences between the observed and simulated peak discharge rates were less than 30 percent. These 22 events accounted for 63 percent of total volume of streamflow observed during the selected 46 peak flow events in Purdy Creek. In Ariel Creek, these 24 peak flow events accounted for 62 percent of the total flow observed during all peak flow events. Differences in observed and simulated peak flow rates and volumes (on a percent basis) were greater during the snowmelt runoff events and summer periods than for other times.A hydrologic modeling study, using the Hydrologic Simulation Program - FORTRAN (HSPF), was conducted in two glaciated watersheds, Purdy Creek and Ariel Creek in northeastern Pennsylvania. Both watersheds have wetlands and poorly drained soils due to low hydraulic conductivity and presence of fragipans. The HSPF model was calibrated in the Purdy Creek watershed and verified in the Ariel Creek watershed for June 1992 to December 1993 period. In Purdy Creek, the total volume of observed streamflow during the entire simulation period was 13.36??106 m3 and the simulated streamflow volume was 13.82??106 m3 (5 percent difference). For the verification simulation in Ariel Creek, the difference between the total observed and simulated flow volumes was 17 percent. Simulated peak flow discharges were within two hours of the observed for 30 of 46 peak flow events (discharge greater than 0.1 m3/sec) in Purdy Creek and 27 of 53 events in Ariel Creek. For 22 of the 46 events in Purdy Creek and 24 of 53 in Ariel Creek, the differences between the observed and simulated peak discharge rates were less than 30 percent. These 22 events accounted for 63 percent of total volume of streamflow observed during the selected 46 peak flow events in Purdy Creek. In Ariel Creek, these 24 peak flow events accounted for 62 percent of the total flow observed during all peak flow events. Differences in observed and simulated peak flow rates and volumes (on a percent basis) were greater during the snowmelt runoff events and summer periods than for other times.
Nam, Sunghyun; Condon, Brian D.; Delhom, Christopher D.; Fontenot, Krystal R.
2016-01-01
The interactions of nanoparticles with polymer hosts have important implications for directing the macroscopic properties of composite fibers, yet little is known about such interactions with hierarchically ordered natural polymers due to the difficulty of achieving uniform dispersion of nanoparticles within semi-crystalline natural fiber. In this study we have homogeneously dispersed silver nanoparticles throughout an entire volume of cotton fiber. The resulting electrostatic interaction and distinct supramolecular structure of the cotton fiber provided a favorable environment for the controlled formation of nanoparticles (12 ± 3 nm in diameter). With a high surface-to-volume ratio, the extensive interfacial contacts of the nanoparticles efficiently “glued” the structural elements of microfibrils together, producing a unique inorganic-organic hybrid substructure that reinforced the multilayered architecture of the cotton fiber. PMID:27849038
NASA Technical Reports Server (NTRS)
Qin, J. X.; Shiota, T.; Thomas, J. D.
2000-01-01
Reconstructed three-dimensional (3-D) echocardiography is an accurate and reproducible method of assessing left ventricular (LV) functions. However, it has limitations for clinical study due to the requirement of complex computer and echocardiographic analysis systems, electrocardiographic/respiratory gating, and prolonged imaging times. Real-time 3-D echocardiography has a major advantage of conveniently visualizing the entire cardiac anatomy in three dimensions and of potentially accurately quantifying LV volumes, ejection fractions, and myocardial mass in patients even in the presence of an LV aneurysm. Although the image quality of the current real-time 3-D echocardiographic methods is not optimal, its widespread clinical application is possible because of the convenient and fast image acquisition. We review real-time 3-D echocardiographic image acquisition and quantitative analysis for the evaluation of LV function and LV mass.
Qin, J X; Shiota, T; Thomas, J D
2000-11-01
Reconstructed three-dimensional (3-D) echocardiography is an accurate and reproducible method of assessing left ventricular (LV) functions. However, it has limitations for clinical study due to the requirement of complex computer and echocardiographic analysis systems, electrocardiographic/respiratory gating, and prolonged imaging times. Real-time 3-D echocardiography has a major advantage of conveniently visualizing the entire cardiac anatomy in three dimensions and of potentially accurately quantifying LV volumes, ejection fractions, and myocardial mass in patients even in the presence of an LV aneurysm. Although the image quality of the current real-time 3-D echocardiographic methods is not optimal, its widespread clinical application is possible because of the convenient and fast image acquisition. We review real-time 3-D echocardiographic image acquisition and quantitative analysis for the evaluation of LV function and LV mass.
NASA Astrophysics Data System (ADS)
Suthar, Shyam Sunder; Purohit, Suresh
2018-05-01
Properties of diesel and biodiesel (produced from corn oil) are used. Densities and viscosities of binary mixture of diesel with biodiesel (produced from corn oil) have been computed by using liquid binary mixture law over the entire range of compositions at T=298.15K and atmospheric pressure. From the computed values of density and viscosities, viscosity deviation (Δη), the excess molar volume (VE) and excess Gibbs energy of activation of viscous flow (ΔG#E) have been calculated. The results of excess volume, excess Gibbs energy of activation of viscous flow and viscosity deviation have been fitted to Redlich -Kister models to estimate the binary coefficients. The results are communicated in terms of the molecular interactions and the best suited composition has been found.
Rune, B; Selvik, G; Kreiborg, S; Sarnäs, K V; Kågström, E
1979-04-01
Craniectomy was performed on a boy with Crouzon's disease at 22 months of age. Metallic implants (tantalum balls, 0.5 mm in diameter) were inserted in the calvaria during surgery, and the child was examined postoperatively by roentgen stereometry at intervals of about 100 days (total observation time, 309 days). The thyroid radiation dose was 250 muGy for one examination. The effect of craniectomy was recorded with a high degree of accuracy in terms of motion of bones and volume changes in the calvaria. Expansion occurred almost entirely through motion of free bone flaps in the frontal region, while a linear craniectomy in the region of the sagittal suture caused small changes. The rate of expansion decreased rapidly and stabilization was recorded about 250 days after surgery.
1956-11-05
fighting des - perately, ever since Gen. Komatsubara and his 500 survivors had per- sonally plunged into the fray on the night of 28 August. Officers of...all ranks were falling on every side, and entire units were de - stroyed to the last man. North of the Holsten River, the Provision- al Heavy...Division CP. The same or- der was also wired In the clear, since the code books had been de - stroyed* Shortly before midnight on 30 August, the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohatt, D; Malhotra, H
Purpose: Conventional treatment plans for lung radiotherapy are created using either the free breathing (FB) scheme which represents the tumor at an arbitrary breathing phase of the patient’s respiratory cycle, or the average computed tomography (ACT) intensity projection over 10-binned phases. Neither method is entirely accurate because of the absence of time dependence of tumor movement. In the present “Hybrid” method, the HU of tumor in 3D space is determined by relative weighting of the HU of the tumor and lung in proportion to the time they spend at that location during the entire breathing cycle. Methods: A Quasar respiratorymore » motion phantom was employed to simulate lung tumor movement. Utilizing 4DCT image scans, volumetric modulated arc therapy (VMAT) plans were generated for three treatment planning scenarios which included conventional FB and ACT schemes, along with a third alternative Hybrid approach. Our internal target volume (ITV) hybrid structure was created using Boolean operation in Eclipse (ver. 11) treatment planning system, where independent sub-regions created by the gross tumor volume (GTV) overlap from the 10 motion phases were each assigned a time weighted CT value. The dose-volume-histograms (DVH) for each scheme were compared and analyzed. Results: Using our hybrid technique, we have demonstrated a reduction of 1.9% – 3.4% in total monitor units with respect to conventional treatment planning strategies, along with a 6 fold improvement in high dose spillage over the FB plan. The higher density ACT and Hybrid schemes also produced a slight enhancement in target conformity and reduction in low dose spillage. Conclusion: All treatment plans created in this study exceeded RTOG protocol criteria. Our results determine the free breathing approach yields an inaccurate account of the target treatment density. A significant decrease in unnecessary lung irradiation can be achieved by implementing Hybrid HU method with ACT method second best.« less
Cima, Robert R; Brown, Michael J; Hebl, James R; Moore, Robin; Rogers, James C; Kollengode, Anantha; Amstutz, Gwendolyn J; Weisbrod, Cheryl A; Narr, Bradly J; Deschamps, Claude
2011-07-01
Operating rooms (ORs) are resource-intense and costly hospital units. Maximizing OR efficiency is essential to maintaining an economically viable institution. OR efficiency projects often focus on a limited number of ORs or cases. Efforts across an entire OR suite have not been reported. Lean and Six Sigma methodologies were developed in the manufacturing industry to increase efficiency by eliminating non-value-added steps. We applied Lean and Six Sigma methodologies across an entire surgical suite to improve efficiency. A multidisciplinary surgical process improvement team constructed a value stream map of the entire surgical process from the decision for surgery to discharge. Each process step was analyzed in 3 domains, ie, personnel, information processed, and time. Multidisciplinary teams addressed 5 work streams to increase value at each step: minimizing volume variation; streamlining the preoperative process; reducing nonoperative time; eliminating redundant information; and promoting employee engagement. Process improvements were implemented sequentially in surgical specialties. Key performance metrics were collected before and after implementation. Across 3 surgical specialties, process redesign resulted in substantial improvements in on-time starts and reduction in number of cases past 5 pm. Substantial gains were achieved in nonoperative time, staff overtime, and ORs saved. These changes resulted in substantial increases in margin/OR/day. Use of Lean and Six Sigma methodologies increased OR efficiency and financial performance across an entire operating suite. Process mapping, leadership support, staff engagement, and sharing performance metrics are keys to enhancing OR efficiency. The performance gains were substantial, sustainable, positive financially, and transferrable to other specialties. Copyright © 2011 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Transverse Aeolian Ridges on Mars: Sediment sources, volumes, and ages.
NASA Astrophysics Data System (ADS)
Berman, D. C.; Balme, M. R.
2014-12-01
Transverse Aeolian Ridges (TARs) are aeolian bedforms that are morphologically and dimensionally distinct from Large Dark Dune (LDD) fields, being generally brighter than, or of similar albedo to, the surrounding terrain. These features are significantly smaller than the LDDs, appear to form normal to local winds, and tend to have simple, transverse, ripple-like morphologies. Whether these small martian bedforms represent large granule ripples, small transverse dunes, or something else entirely is currently under debate. The spatial distribution of TARs provides important information about where on Mars aeolian sediments are concentrated, and determining their volume can help us constrain the sediment transport regime on Mars. Also, if we can determine if TARs were active only in the past, or whether TARs are mobile under today's wind conditions, then we can begin to assess when and where TARs are/were active over Mars' recent geological history. Thus TARs have the potential for being indicators/records of climate change on Mars. In this work we build on previous work [1,2] and focus on the local/regional scale. We have identified six regional study areas, each 5° by 5°, to investigate the behavior of TARs in detail; one in the northern hemisphere, three in the equatorial band, and two in the southern hemisphere. We have systematically mapped TAR and LDD deposits in each study area to constrain sediment transport pathways and identify sediment sources. In general, TAR sediments appear to be tied to local sources such as LDDs or layered terrains. HiRISE DTMs were utilized to measure TAR heights, widths, wavelengths, and lengths to calculate sediment volumes and estimate volumes over entire study areas based on mapping. Crater count analyses on contiguous TAR fields in the equatorial regions, where the bedforms appear more lithified, reveal ages of several million years. Mid-latitude TAR fields do not show any superposed craters, suggesting much younger deposits. References: [1] Balme, M.R., D.C. Berman, M.C. Bourke, and J.R. Zimbelman, Transverse Aeolian Ridges (TARs) on Mars, Geomorphology, 101, 703-720, 2008. [2] Berman, D.C., M.R. Balme, S. Rafkin, and J.R. Zimbelman, Transverse Aeolian Ridges (TARs) on Mars II: Distributions, orientations, and ages, Icarus 213, 116-130, 2011
High day-to-day reliability in lower leg volume measured by water displacement.
Pasley, Jeffrey D; O'Connor, Patrick J
2008-07-01
The day-to-day reliability of lower leg volume is poorly documented. This investigation determined the day-to-day reliability of lower leg volume (soleus and gastrocnemius) measured using water displacement. Thirty young adults (15 men and 15 women) had their right lower leg volume measured by water displacement on five separate occasions. The participants performed normal activities of daily living and were measured at the same time of day after being seated for 30 min. The results revealed a high day-to-day reliability for lower leg volume. The mean percentage change in lower leg volume across days compared to day 1 ranged between 0 and 0.37%. The mean within subjects coefficient of variation in lower leg volume was 0.72% and the coefficient of variation for the entire sample across days ranged from 5.66 to 6.32%. A two way mixed model intraclass correlation (30 subjects x 5 days) showed that the lower leg volume measurement was highly reliable (ICC = 0.972). Foot and total lower leg volumes showed similarly high reliability. Water displacement offers a cost effective and reliable solution for the measurement of lower leg edema across days.
The short-term effects of fertilization on loblolly pine photosynthesis and biomass
Nathan King; John Seiler; Thomas R. Fox; Kurt Johnsen
2006-01-01
The physiological processes in loblolly pine leading to enhanced growth in response to fertilization have not been clearly established. We tracked net photosynthesis (Pn), height, basal diameter, and volume changes in loblolly pine seedlings in response to fertilization during the entire 2004 growing season. Pn measurements...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This volume contains the entire proceedings of the solar update. All papers presented by DOE officials, DOE contractors, and demonstration site representatives are presented, as well as summaries of all workshops, comments from questionnaires, and a listing of all participants. Twenty-eight papers are included. Two were abstracted previously for EDB. Separate abstracts were prepared for twenty-six. (MHR)
ERIC Educational Resources Information Center
Cuicchi, Paul M.; Winter, Joshua B.; Hamil, Burnette
2003-01-01
Presents an activity to teach buoyancy. The lab determines what mass of sand can be added to the open end of hollow plastic containers of various shapes so that objects just float at the surface, without sinking, with their entire volume submerged. Discusses Archimedes' principle and aligns with current national science education standards.…
The EDUTECH Report, 2002-2003.
ERIC Educational Resources Information Center
Warger, Thomas, Ed.
2003-01-01
This document consists of 12 issues, an entire volume year, of "The EDUTECH Report." The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, and a question and answer column. Most issues also contain brief quotations on education…
A multiresolution approach to iterative reconstruction algorithms in X-ray computed tomography.
De Witte, Yoni; Vlassenbroeck, Jelle; Van Hoorebeke, Luc
2010-09-01
In computed tomography, the application of iterative reconstruction methods in practical situations is impeded by their high computational demands. Especially in high resolution X-ray computed tomography, where reconstruction volumes contain a high number of volume elements (several giga voxels), this computational burden prevents their actual breakthrough. Besides the large amount of calculations, iterative algorithms require the entire volume to be kept in memory during reconstruction, which quickly becomes cumbersome for large data sets. To overcome this obstacle, we present a novel multiresolution reconstruction, which greatly reduces the required amount of memory without significantly affecting the reconstructed image quality. It is shown that, combined with an efficient implementation on a graphical processing unit, the multiresolution approach enables the application of iterative algorithms in the reconstruction of large volumes at an acceptable speed using only limited resources.
Volume-of-Change Cone-Beam CT for Image-Guided Surgery
Lee, Junghoon; Stayman, J. Webster; Otake, Yoshito; Schafer, Sebastian; Zbijewski, Wojciech; Khanna, A. Jay; Prince, Jerry L.; Siewerdsen, Jeffrey H.
2012-01-01
C-arm cone-beam CT (CBCT) can provide intraoperative 3D imaging capability for surgical guidance, but workflow and radiation dose are the significant barriers to broad utilization. One main reason is that each 3D image acquisition requires a complete scan with a full radiation dose to present a completely new 3D image every time. In this paper, we propose to utilize patient-specific CT or CBCT as prior knowledge to accurately reconstruct the aspects of the region that have changed by the surgical procedure from only a sparse set of x-rays. The proposed methods consist of a 3D-2D registration between the prior volume and a sparse set of intraoperative x-rays, creating digitally reconstructed radiographs (DRR) from the registered prior volume, computing difference images by subtracting DRRs from the intraoperative x-rays, a penalized likelihood reconstruction of the volume of change (VOC) from the difference images, and finally a fusion of VOC reconstruction with the prior volume to visualize the entire surgical field. When the surgical changes are local and relatively small, the VOC reconstruction involves only a small volume size and a small number of projections, allowing less computation and lower radiation dose than is needed to reconstruct the entire surgical field. We applied this approach to sacroplasty phantom data obtained from a CBCT test bench and vertebroplasty data with a fresh cadaver acquired from a C-arm CBCT system with a flat-panel detector (FPD). The VOCs were reconstructed from varying number of images (10–66 images) and compared to the CBCT ground truth using four different metrics (mean squared error, correlation coefficient, structural similarity index, and perceptual difference model). The results show promising reconstruction quality with structural similarity to the ground truth close to 1 even when only 15–20 images were used, allowing dose reduction by the factor of 10–20. PMID:22801026
Volume-of-change cone-beam CT for image-guided surgery
NASA Astrophysics Data System (ADS)
Lee, Junghoon; Webster Stayman, J.; Otake, Yoshito; Schafer, Sebastian; Zbijewski, Wojciech; Khanna, A. Jay; Prince, Jerry L.; Siewerdsen, Jeffrey H.
2012-08-01
C-arm cone-beam CT (CBCT) can provide intraoperative 3D imaging capability for surgical guidance, but workflow and radiation dose are the significant barriers to broad utilization. One main reason is that each 3D image acquisition requires a complete scan with a full radiation dose to present a completely new 3D image every time. In this paper, we propose to utilize patient-specific CT or CBCT as prior knowledge to accurately reconstruct the aspects of the region that have changed by the surgical procedure from only a sparse set of x-rays. The proposed methods consist of a 3D-2D registration between the prior volume and a sparse set of intraoperative x-rays, creating digitally reconstructed radiographs (DRRs) from the registered prior volume, computing difference images by subtracting DRRs from the intraoperative x-rays, a penalized likelihood reconstruction of the volume of change (VOC) from the difference images, and finally a fusion of VOC reconstruction with the prior volume to visualize the entire surgical field. When the surgical changes are local and relatively small, the VOC reconstruction involves only a small volume size and a small number of projections, allowing less computation and lower radiation dose than is needed to reconstruct the entire surgical field. We applied this approach to sacroplasty phantom data obtained from a CBCT test bench and vertebroplasty data with a fresh cadaver acquired from a C-arm CBCT system with a flat-panel detector. The VOCs were reconstructed from a varying number of images (10-66 images) and compared to the CBCT ground truth using four different metrics (mean squared error, correlation coefficient, structural similarity index and perceptual difference model). The results show promising reconstruction quality with structural similarity to the ground truth close to 1 even when only 15-20 images were used, allowing dose reduction by the factor of 10-20.
A modified ATI technique for nowcasting convective rain volumes over areas. [area-time integrals
NASA Technical Reports Server (NTRS)
Makarau, Amos; Johnson, L. Ronald; Doneaud, Andre A.
1988-01-01
This paper explores the applicability of the area-time-integral (ATI) technique for the estimation of the growth portion only of a convective storm (while the rain volume is computed using the entire life history of the event) and for nowcasting the total rain volume of a convective system at the stage of its maximum development. For these purposes, the ATIs were computed from the digital radar data (for 1981-1982) from the North Dakota Cloud Modification Project, using the maximum echo area (ATIA) no less than 25 dBz, the maximum reflectivity, and the maximum echo height as the end of the growth portion of the convective event. Linear regression analysis demonstrated that correlations between total rain volume or the maximum rain volume versus ATIA were the strongest. The uncertainties obtained were comparable to the uncertainties which typically occur in rain volume estimates obtained from radar data employing Z-R conversion followed by space and time integration. This demonstrates that the total rain volume of a storm can be nowcasted at its maximum stage of development.
Noninvasive enhanced mid-IR imaging of breast cancer development in vivo
NASA Astrophysics Data System (ADS)
Case, Jason R.; Young, Madison A.; Dréau, D.; Trammell, Susan R.
2015-11-01
Lumpectomy coupled with radiation therapy and/or chemotherapy is commonly used to treat breast cancer patients. We are developing an enhanced thermal IR imaging technique that has the potential to provide real-time imaging to guide tissue excision during a lumpectomy by delineating tumor margins. This enhanced thermal imaging method is a combination of IR imaging (8 to 10 μm) and selective heating of blood (˜0.5°C) relative to surrounding water-rich tissue using LED sources at low powers. Postacquisition processing of these images highlights temporal changes in temperature and the presence of vascular structures. In this study, fluorescent, standard thermal, and enhanced thermal imaging modalities, as well as physical caliper measurements, were used to monitor breast cancer tumor volumes over a 30-day study period in 19 mice implanted with 4T1-RFP tumor cells. Tumor volumes calculated from fluorescent imaging follow an exponential growth curve for the first 22 days of the study. Cell necrosis affected the tumor volume estimates based on the fluorescent images after day 22. The tumor volumes estimated from enhanced thermal imaging, standard thermal imaging, and caliper measurements all show exponential growth over the entire study period. A strong correlation was found between tumor volumes estimated using fluorescent imaging, standard IR imaging, and caliper measurements with enhanced thermal imaging, indicating that enhanced thermal imaging monitors tumor growth. Further, the enhanced IR images reveal a corona of bright emission along the edges of the tumor masses associated with the tumor margin. In the future, this IR technique might be used to estimate tumor margins in real time during surgical procedures.
The Concentration of Opioid Prescriptions by Providers and Patients in the Oregon Medicaid Program
Kim, Hyunjee; Hartung, Daniel; Jacob, Lorie; McCarty, Dennis; McConnell, K. John
2016-01-01
Objective This study seeks to understand the distribution of opioid prescribing across providers and patients, and examines how this concentration predicts opioid misuse. Methods Using 2013 Oregon Medicaid claims and National Provider ID registry, this study identified patients who filled at least one opioid prescription and providers who prescribed opioids for those patients (N=61,477 Medicaid patients). This study examined the distribution of opioid prescriptions by provider and patient, the extent to which high-volume opioid use was associated with potential opioid misuse, and how this association changes when patients received opioids from providers in the top decile of morphine equivalents (MEQ) prescribed in 2013. This study used four indicators of opioid misuse: doctor and pharmacy shopping for opioid prescriptions, opioid prescription overlap, and opioid and benzodiazepine prescription overlap. Results Opioid use and prescriptions were heavily concentrated among the top 10% opioid users and prescribers. Those high-volume opioid users and prescribers accounted for 83.2% and 80.8% in MEQ of entire opioids prescribed. Patients’ increasing use of MEQ was associated with most measures of opioid misuse. Patients receiving opioids from high-volume prescribers had a higher probability of opioid prescription overlap and opioid and benzodiazepine prescription overlap, but the increase was significant only among patients who received high doses of opioids and the size of the increase was modest. Conclusions Whereas current policies emphasize reducing opioid prescriptions across all patients and providers, study results suggest potential for policies that focus on high-volume opioid users and prescribers. PMID:26766755
Kim, Hyunjee; Hartung, Daniel M; Jacob, Reside L; McCarty, Dennis; McConnell, K John
2016-04-01
This study examined the distribution of opioid prescribing across providers and patients and the extent to which concentrated distribution predicts opioid misuse. Using 2013 Oregon Medicaid claims and the National Provider Identifier Registry, this study identified patients who filled at least one opioid prescription and providers who prescribed opioids for those patients (N=61,477 Medicaid beneficiaries). This study examined the distribution of opioid prescriptions by provider and patient, the extent to which high-volume opioid use was associated with potential opioid misuse, and how this association changed when patients received opioids from providers in the top decile of morphine-equivalent doses (MEQ) prescribed in 2013. This study used four indicators of opioid misuse: doctor and pharmacy shopping for opioid prescriptions, opioid prescription overlap, and opioid and benzodiazepine prescription overlap. Opioid use and prescriptions were heavily concentrated among the top 10% of opioid users and prescribers. Those high-volume opioid users and prescribers accounted for, respectively, 83.2% and 80.8% in MEQ of entire opioids prescribed. Patients' increasing use of opioids (by MEQ) was associated with most measures of opioid misuse. Patients receiving opioids from high-volume prescribers had a higher probability of opioid prescription overlap and opioid and benzodiazepine prescription overlap compared with other patients, but the difference was significant only among patients who received high doses of opioids, and the size of the difference was modest. Whereas current policies emphasize reducing opioid prescriptions across all patients and providers, study results suggest that focusing policies on high-volume opioid users and prescribers may be more beneficial.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Engberg, L; KTH Royal Institute of Technology, Stockholm; Eriksson, K
Purpose: To formulate objective functions of a multicriteria fluence map optimization model that correlate well with plan quality metrics, and to solve this multicriteria model by convex approximation. Methods: In this study, objectives of a multicriteria model are formulated to explicitly either minimize or maximize a dose-at-volume measure. Given the widespread agreement that dose-at-volume levels play important roles in plan quality assessment, these objectives correlate well with plan quality metrics. This is in contrast to the conventional objectives, which are to maximize clinical goal achievement by relating to deviations from given dose-at-volume thresholds: while balancing the new objectives means explicitlymore » balancing dose-at-volume levels, balancing the conventional objectives effectively means balancing deviations. Constituted by the inherently non-convex dose-at-volume measure, the new objectives are approximated by the convex mean-tail-dose measure (CVaR measure), yielding a convex approximation of the multicriteria model. Results: Advantages of using the convex approximation are investigated through juxtaposition with the conventional objectives in a computational study of two patient cases. Clinical goals of each case respectively point out three ROI dose-at-volume measures to be considered for plan quality assessment. This is translated in the convex approximation into minimizing three mean-tail-dose measures. Evaluations of the three ROI dose-at-volume measures on Pareto optimal plans are used to represent plan quality of the Pareto sets. Besides providing increased accuracy in terms of feasibility of solutions, the convex approximation generates Pareto sets with overall improved plan quality. In one case, the Pareto set generated by the convex approximation entirely dominates that generated with the conventional objectives. Conclusion: The initial computational study indicates that the convex approximation outperforms the conventional objectives in aspects of accuracy and plan quality.« less
Liem, Franziskus; Mérillat, Susan; Bezzola, Ladina; Hirsiger, Sarah; Philipp, Michel; Madhyastha, Tara; Jäncke, Lutz
2015-03-01
FreeSurfer is a tool to quantify cortical and subcortical brain anatomy automatically and noninvasively. Previous studies have reported reliability and statistical power analyses in relatively small samples or only selected one aspect of brain anatomy. Here, we investigated reliability and statistical power of cortical thickness, surface area, volume, and the volume of subcortical structures in a large sample (N=189) of healthy elderly subjects (64+ years). Reliability (intraclass correlation coefficient) of cortical and subcortical parameters is generally high (cortical: ICCs>0.87, subcortical: ICCs>0.95). Surface-based smoothing increases reliability of cortical thickness maps, while it decreases reliability of cortical surface area and volume. Nevertheless, statistical power of all measures benefits from smoothing. When aiming to detect a 10% difference between groups, the number of subjects required to test effects with sufficient power over the entire cortex varies between cortical measures (cortical thickness: N=39, surface area: N=21, volume: N=81; 10mm smoothing, power=0.8, α=0.05). For subcortical regions this number is between 16 and 76 subjects, depending on the region. We also demonstrate the advantage of within-subject designs over between-subject designs. Furthermore, we publicly provide a tool that allows researchers to perform a priori power analysis and sensitivity analysis to help evaluate previously published studies and to design future studies with sufficient statistical power. Copyright © 2014 Elsevier Inc. All rights reserved.
Strength statistics of single crystals and metallic glasses under small stressed volumes
Gao, Yanfei; Bei, Hongbin
2016-05-13
It has been well documented that plastic deformation of crystalline and amorphous metals/alloys shows a general trend of “smaller is stronger”. The majority of the experimental and modeling studies along this line have been focused on finding and reasoning the scaling slope or exponent in the logarithmic plot of strength versus size. In contrast to this view, here we show that the universal picture should be the thermally activated nucleation mechanisms in small stressed volume, the stochastic behavior as to find the weakest links in intermediate sizes of the stressed volume, and the convolution of these two mechanisms with respectmore » to variables such as indenter radius in nanoindentation pop-in, crystallographic orientation, pre-strain level, sample length as in uniaxial tests, and others. Furthermore, experiments that cover the entire spectrum of length scales and a unified model that treats both thermal activation and spatial stochasticity have discovered new perspectives in understanding and correlating the strength statistics in a vast of observations in nanoindentation, micro-pillar compression, and fiber/whisker tension tests of single crystals and metallic glasses.« less
Collected software engineering papers, volume 9
NASA Technical Reports Server (NTRS)
1991-01-01
This document is a collection of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) from November 1990 through October 1991. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. This is the ninth such volume of technical papers produced by the SEL. Although these papers cover several topics related to software engineering, they do not encompass the entire scope of SEL activities and interests. For the convenience of this presentation, the eight papers contained here are grouped into three major categories: (1) software models studies; (2) software measurement studies; and (3) Ada technology studies. The first category presents studies on reuse models, including a software reuse model applied to maintenance and a model for an organization to support software reuse. The second category includes experimental research methods and software measurement techniques. The third category presents object-oriented approaches using Ada and object-oriented features proposed for Ada. The SEL is actively working to understand and improve the software development process at GSFC.
Kansa, E.J.; Anderson, B.L.; Wijesinghe, A.M.; Viani, B.E.
1999-05-25
This invention provides a process to tremendously reduce the bulk volume of contaminants obtained from an effluent stream produced subsurface remediation. The chemicals used for the subsurface remediation are reclaimed for recycling to the remediation process. Additional reductions in contaminant bulk volume are achieved by the ultra-violet light destruction of halogenated hydrocarbons, and the complete oxidation of hydrophobic fuel hydrocarbons and hydrophilic hydrocarbons. The contaminated bulk volume will arise primarily from the disposal of the toxic metal ions. The entire process is modular, so if there are any technological breakthroughs in one or more of the component process modules, such modules can be readily replaced. 3 figs.
3D Myocardial Elastography In Vivo.
Papadacci, Clement; Bunting, Ethan A; Wan, Elaine Y; Nauleau, Pierre; Konofagou, Elisa E
2017-02-01
Strain evaluation is of major interest in clinical cardiology as it can quantify the cardiac function. Myocardial elastography, a radio-frequency (RF)-based cross-correlation method, has been developed to evaluate the local strain distribution in the heart in vivo. However, inhomogeneities such as RF ablation lesions or infarction require a three-dimensional approach to be measured accurately. In addition, acquisitions at high volume rate are essential to evaluate the cardiac strain in three dimensions. Conventional focused transmit schemes using 2D matrix arrays, trade off sufficient volume rate for beam density or sector size to image rapid moving structure such as the heart, which lowers accuracy and precision in the strain estimation. In this study, we developed 3D myocardial elastography at high volume rates using diverging wave transmits to evaluate the local axial strain distribution in three dimensions in three open-chest canines before and after radio-frequency ablation. Acquisitions were performed with a 2.5 MHz 2D matrix array fully programmable used to emit 2000 diverging waves at 2000 volumes/s. Incremental displacements and strains enabled the visualization of rapid events during the QRS complex along with the different phases of the cardiac cycle in entire volumes. Cumulative displacement and strain volumes depict high contrast between non-ablated and ablated myocardium at the lesion location, mapping the tissue coagulation. 3D myocardial strain elastography could thus become an important technique to measure the regional strain distribution in three dimensions in humans.
Estimating Highway Volumes Using Vehicle Probe Data - Proof of Concept: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hou, Yi; Young, Stanley E; Sadabadi, Kaveh
This paper examines the feasibility of using sampled commercial probe data in combination with validated continuous counter data to accurately estimate vehicle volume across the entire roadway network, for any hour during the year. Currently either real time or archived volume data for roadways at specific times are extremely sparse. Most volume data are average annual daily traffic (AADT) measures derived from the Highway Performance Monitoring System (HPMS). Although methods to factor the AADT to hourly averages for typical day of week exist, actual volume data is limited to a sparse collection of locations in which volumes are continuously recorded.more » This paper explores the use of commercial probe data to generate accurate volume measures that span the highway network providing ubiquitous coverage in space, and specific point-in-time measures for a specific date and time. The paper examines the need for the data, fundamental accuracy limitations based on a basic statistical model that take into account the sampling nature of probe data, and early results from a proof of concept exercise revealing the potential of probe type data calibrated with public continuous count data to meet end user expectations in terms of accuracy of volume estimates.« less
Left ventricular endocardial surface detection based on real-time 3D echocardiographic data
NASA Technical Reports Server (NTRS)
Corsi, C.; Borsari, M.; Consegnati, F.; Sarti, A.; Lamberti, C.; Travaglini, A.; Shiota, T.; Thomas, J. D.
2001-01-01
OBJECTIVE: A new computerized semi-automatic method for left ventricular (LV) chamber segmentation is presented. METHODS: The LV is imaged by real-time three-dimensional echocardiography (RT3DE). The surface detection model, based on level set techniques, is applied to RT3DE data for image analysis. The modified level set partial differential equation we use is solved by applying numerical methods for conservation laws. The initial conditions are manually established on some slices of the entire volume. The solution obtained for each slice is a contour line corresponding with the boundary between LV cavity and LV endocardium. RESULTS: The mathematical model has been applied to sequences of frames of human hearts (volume range: 34-109 ml) imaged by 2D and reconstructed off-line and RT3DE data. Volume estimation obtained by this new semi-automatic method shows an excellent correlation with those obtained by manual tracing (r = 0.992). Dynamic change of LV volume during the cardiac cycle is also obtained. CONCLUSION: The volume estimation method is accurate; edge based segmentation, image completion and volume reconstruction can be accomplished. The visualization technique also allows to navigate into the reconstructed volume and to display any section of the volume.
Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions
Zhang, Jie; Patterson, Robert
2014-01-01
This study is aimed at investigating the variability in resistivity changes in the lung region as a function of air volume, electrode plane and body position. Six normal subjects (33.8 ± 4.7 years, range from 26 to 37 years) were studied using the Sheffield Electrical Impedance Tomography (EIT) portable system. Three transverse planes at the level of second intercostal space, the level of the xiphisternal joint, and midway between upper and lower locations were chosen for measurements. For each plane, sixteen electrodes were uniformly positioned around the thorax. Data were collected with the breath held at end expiration and after inspiring 0.5, 1.0, or 1.5 liters of air from end expiration, with the subject in both the supine and sitting position. The average resistivity change in five regions, two 8x8 pixel local regions in the right lung, entire right, entire left and total lung regions, were calculated. The results show the resistivity change averaged over electrode positions and subject positions was 7-9% per liter of air, with a slightly larger resistivity change of 10 % per liter air in the lower electrode plane. There was no significant difference (p>0.05) between supine and sitting. The two 8x8 regions show a larger inter individual variability (coefficient of variation, CV, is from 30% to 382%) compared to the entire left, entire right and total lung (CV is from 11% to 51%). The results for the global regions are more consistent. The large inter individual variability appears to be a problem for clinical applications of EIT, such as regional ventilation. The variability may be mitigated by choosing appropriate electrode plane, body position and region of interest for the analysis. PMID:25110529
Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions.
Zhang, Jie; Patterson, Robert
2014-01-01
This study is aimed at investigating the variability in resistivity changes in the lung region as a function of air volume, electrode plane and body position. Six normal subjects (33.8 ± 4.7 years, range from 26 to 37 years) were studied using the Sheffield Electrical Impedance Tomography (EIT) portable system. Three transverse planes at the level of second intercostal space, the level of the xiphisternal joint, and midway between upper and lower locations were chosen for measurements. For each plane, sixteen electrodes were uniformly positioned around the thorax. Data were collected with the breath held at end expiration and after inspiring 0.5, 1.0, or 1.5 liters of air from end expiration, with the subject in both the supine and sitting position. The average resistivity change in five regions, two 8x8 pixel local regions in the right lung, entire right, entire left and total lung regions, were calculated. The results show the resistivity change averaged over electrode positions and subject positions was 7-9% per liter of air, with a slightly larger resistivity change of 10 % per liter air in the lower electrode plane. There was no significant difference (p>0.05) between supine and sitting. The two 8x8 regions show a larger inter individual variability (coefficient of variation, CV, is from 30% to 382%) compared to the entire left, entire right and total lung (CV is from 11% to 51%). The results for the global regions are more consistent. The large inter individual variability appears to be a problem for clinical applications of EIT, such as regional ventilation. The variability may be mitigated by choosing appropriate electrode plane, body position and region of interest for the analysis.
Gas Flow in the Capillary of the Atmosphere-to-Vacuum Interface of Mass Spectrometers
NASA Astrophysics Data System (ADS)
Skoblin, Michael; Chudinov, Alexey; Soulimenkov, Ilia; Brusov, Vladimir; Kozlovskiy, Viacheslav
2017-10-01
Numerical simulations of a gas flow through a capillary being a part of mass spectrometer atmospheric interface were performed using a detailed laminar flow model. The simulated interface consisted of atmospheric and forevacuum volumes connected via a thin capillary. The pressure in the forevacuum volume where the gas was expanding after passing through the capillary was varied in the wide range from 10 to 900 mbar in order to study the volume flow rate as well as the other flow parameters as functions of the pressure drop between the atmospheric and forevacuum volumes. The capillary wall temperature was varied in the range from 24 to 150 °C. Numerical integration of the complete system of Navier-Stokes equations for a viscous compressible gas taking into account the heat transfer was performed using the standard gas dynamic simulation software package ANSYS CFX. The simulation results were compared with experimental measurements of gas flow parameters both performed using our experimental setup and taken from the literature. The simulated volume flow rates through the capillary differed no more than by 10% from the measured ones over the entire pressure and temperatures ranges. A conclusion was drawn that the detailed digital laminar model is able to quantitatively describe the measured gas flow rates through the capillaries under conditions considered. [Figure not available: see fulltext.
Gas Flow in the Capillary of the Atmosphere-to-Vacuum Interface of Mass Spectrometers.
Skoblin, Michael; Chudinov, Alexey; Soulimenkov, Ilia; Brusov, Vladimir; Kozlovskiy, Viacheslav
2017-10-01
Numerical simulations of a gas flow through a capillary being a part of mass spectrometer atmospheric interface were performed using a detailed laminar flow model. The simulated interface consisted of atmospheric and forevacuum volumes connected via a thin capillary. The pressure in the forevacuum volume where the gas was expanding after passing through the capillary was varied in the wide range from 10 to 900 mbar in order to study the volume flow rate as well as the other flow parameters as functions of the pressure drop between the atmospheric and forevacuum volumes. The capillary wall temperature was varied in the range from 24 to 150 °C. Numerical integration of the complete system of Navier-Stokes equations for a viscous compressible gas taking into account the heat transfer was performed using the standard gas dynamic simulation software package ANSYS CFX. The simulation results were compared with experimental measurements of gas flow parameters both performed using our experimental setup and taken from the literature. The simulated volume flow rates through the capillary differed no more than by 10% from the measured ones over the entire pressure and temperatures ranges. A conclusion was drawn that the detailed digital laminar model is able to quantitatively describe the measured gas flow rates through the capillaries under conditions considered. Graphical Abstract ᅟ.
Genetic and environmental influences on mean diffusivity and volume in subcortical brain regions.
Gillespie, Nathan A; Neale, Michael C; Hagler, Donald J; Eyler, Lisa T; Fennema-Notestine, Christine; Franz, Carol E; Lyons, Michael J; McEvoy, Linda K; Dale, Anders M; Panizzon, Matthew S; Kremen, William S
2017-05-01
Increased mean diffusivity (MD) is hypothesized to reflect tissue degeneration and may provide subtle indicators of neuropathology as well as age-related brain changes in the absence of volumetric differences. Our aim was to determine the degree to which genetic and environmental variation in subcortical MD is distinct from variation in subcortical volume. Data were derived from a sample of 387 male twins (83 MZ twin pairs, 55 DZ twin pairs, and 111 incomplete twin pairs) who were MRI scanned as part of the Vietnam Era Twin Study of Aging. Quantitative estimates of MD and volume for 7 subcortical regions were obtained: thalamus, caudate nucleus, putamen, pallidum, hippocampus, amygdala, and nucleus accumbens. After adjusting for covariates, bivariate twin models were fitted to estimate the size and significance of phenotypic, genotypic, and environmental correlations between MD and volume at each subcortical region. With the exception of the amygdala, familial aggregation in MD was entirely explained by additive genetic factors across all subcortical regions with estimates ranging from 46 to 84%. Based on bivariate twin modeling, variation in subcortical MD appears to be both genetically and environmentally unrelated to individual differences in subcortical volume. Therefore, subcortical MD may be an alternative biomarker of brain morphology for complex traits worthy of future investigation. Hum Brain Mapp 38:2589-2598, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Bone mineral density across a range of physical activity volumes: NHANES 2007-2010.
Whitfield, Geoffrey P; Kohrt, Wendy M; Pettee Gabriel, Kelley K; Rahbar, Mohammad H; Kohl, Harold W
2015-02-01
The association between aerobic physical activity volume and bone mineral density (BMD) is not completely understood. The purpose of this study was to clarify the association between BMD and aerobic activity across a broad range of activity volumes, particularly volumes between those recommended in the 2008 Physical Activity Guidelines for Americans and those of trained endurance athletes. Data from the 2007-2010 National Health and Nutrition Examination Survey were used to quantify the association between reported physical activity and BMD at the lumbar spine and proximal femur across the entire range of activity volumes reported by US adults. Participants were categorized into multiples of the minimum guideline-recommended volume based on reported moderate- and vigorous-intensity leisure activity. Lumbar and proximal femur BMD were assessed with dual-energy x-ray absorptiometry. Among women, multivariable-adjusted linear regression analyses revealed no significant differences in lumbar BMD across activity categories, whereas proximal femur BMD was significantly higher among those who exceeded the guidelines by 2-4 times than those who reported no activity. Among men, multivariable-adjusted BMD at both sites neared its highest values among those who exceeded the guidelines by at least 4 times and was not progressively higher with additional activity. Logistic regression estimating the odds of low BMD generally echoed the linear regression results. The association between physical activity volume and BMD is complex. Among women, exceeding guidelines by 2-4 times may be important for maximizing BMD at the proximal femur, whereas among men, exceeding guidelines by ≥4 times may be beneficial for lumbar and proximal femur BMD.
Chvetsov, Alexei V; Dong, Lei; Palta, Jantinder R; Amdur, Robert J
2009-10-01
To develop a fast computational radiobiologic model for quantitative analysis of tumor volume during fractionated radiotherapy. The tumor-volume model can be useful for optimizing image-guidance protocols and four-dimensional treatment simulations in proton therapy that is highly sensitive to physiologic changes. The analysis is performed using two approximations: (1) tumor volume is a linear function of total cell number and (2) tumor-cell population is separated into four subpopulations: oxygenated viable cells, oxygenated lethally damaged cells, hypoxic viable cells, and hypoxic lethally damaged cells. An exponential decay model is used for disintegration and removal of oxygenated lethally damaged cells from the tumor. We tested our model on daily volumetric imaging data available for 14 head-and-neck cancer patients treated with an integrated computed tomography/linear accelerator system. A simulation based on the averaged values of radiobiologic parameters was able to describe eight cases during the entire treatment and four cases partially (50% of treatment time) with a maximum 20% error. The largest discrepancies between the model and clinical data were obtained for small tumors, which may be explained by larger errors in the manual tumor volume delineation procedure. Our results indicate that the change in gross tumor volume for head-and-neck cancer can be adequately described by a relatively simple radiobiologic model. In future research, we propose to study the variation of model parameters by fitting to clinical data for a cohort of patients with head-and-neck cancer and other tumors. The potential impact of other processes, like concurrent chemotherapy, on tumor volume should be evaluated.
Pore architecture of nanoporous gold and titania by hydrogen thermoporometry
Johnston, L. T.; Biener, M. M.; Ye, J. C.; ...
2015-07-10
Nanoporous gold (NPG) and materials derived from it by templating have complex pore architecture that determines their technologically relevant physical properties. Here, we apply high-resolution hydrogen thermoporometry to study the pore structure of NPG and NPG-derived titania nanofoam (TNF). Results reveal complex multimodal pore size distributions for NPG and TNF. The freezing–melting hysteresis is pronounced, with freezing and melting scans having entirely different shapes. Experiments involving partial freeze–melt cycles reveal the lack of direct correlation between individual freezing and melting peaks, pointing to phenomena that are beyond the Gibbs-Thomson formalism. The depression of the average freezing temperature scales linearly withmore » the ratio of the internal surface area (measured by gas sorption) and the total pore volume derived from the density of monoliths. In conclusion, thermoporometry yields total pore volumes in good agreement with those derived from monolith densities for both NPG and TNF.« less
Convective rain rates and their evolution during storms in a semiarid climate
NASA Technical Reports Server (NTRS)
Doneaud, A. A.; Miller, J. R., Jr.; Ionescu-Niscov, S.
1984-01-01
The semiarid climate of the U.S. northern High Plains region has been studied with respect to rain rates and their evolution during summertime convective storms, using radar data from a total of 750 radar echo clusters. Analysis of this data suggests that the average rain rate R among storms is in a first approximation independent of the total rain volume, if the entire storm duration is considered in the averaging process. R primarily depends on the reflectivity threshold considered in calculating the area coverage integrated over the lifetime of the storm. R evolution during storms is analyzed by dividing each storm lifetime into 10 min, 1, 2, and 4 hours, as well as growing and decaying periods. The value of R remained independent of the total rain volume when the growing or decaying periods of storms were considered separately.
Pore architecture of nanoporous gold and titania by hydrogen thermoporometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnston, L. T.; Biener, M. M.; Ye, J. C.
Nanoporous gold (NPG) and materials derived from it by templating have complex pore architecture that determines their technologically relevant physical properties. Here, we apply high-resolution hydrogen thermoporometry to study the pore structure of NPG and NPG-derived titania nanofoam (TNF). Results reveal complex multimodal pore size distributions for NPG and TNF. The freezing–melting hysteresis is pronounced, with freezing and melting scans having entirely different shapes. Experiments involving partial freeze–melt cycles reveal the lack of direct correlation between individual freezing and melting peaks, pointing to phenomena that are beyond the Gibbs-Thomson formalism. The depression of the average freezing temperature scales linearly withmore » the ratio of the internal surface area (measured by gas sorption) and the total pore volume derived from the density of monoliths. In conclusion, thermoporometry yields total pore volumes in good agreement with those derived from monolith densities for both NPG and TNF.« less
Boito, S M E; Struijk, P C; Pop, G A M; Visser, W; Steegers, E A P; Wladimiroff, J W
2004-04-01
To establish the effects of plasma volume expansion (PVE) followed by intravenous dihydralazine (DH) administration on maternal whole blood viscosity (WBV) and hematocrit, uteroplacental and fetoplacental downstream impedance and umbilical venous (UV) volume flow in pre-eclampsia. In 13 pre-eclamptic women maternal and fetal hemodynamics were established by means of combined measurement of maternal arterial blood pressure (BP), WBV, hematocrit and uterine artery (UtA) resistance index (RI) in addition to umbilical artery (UA) pulsatility index (PI) and UV volume flow obtained from UV vessel area and UV time-averaged flow velocity. In each woman all parameters were measured four times at baseline, after PVE, after DH and 24 h after the start of treatment. Maternal diastolic BP, hematocrit and WBV display a significant reduction after PVE. In the fetus UA PI decreases significantly whereas a significant increase in UV cross-sectional area was detected. After maternal DH administration, arterial systolic and diastolic BP and UA PI show a significant decrease compared with the measurements following PVE. At 24 h, only maternal systolic and diastolic BP display a significant further decrease. No significant changes were established for the UtA RI, UV time-averaged velocity and UV volume flow during the entire study period. During pre-eclampsia, maternal PVE followed by DH administration results in a significant reduction in maternal diastolic BP, maternal hematocrit and WBV. Maternal PVE is associated with a significant increase in UV cross-sectional area and a non-significant rise of 11% in UV volume flow. Maternal DH administration does not result in any change in UV cross-sectional area. However, UA PI decreases significantly after both PVE and DH treatment. Copyright 2004 ISUOG.
Brolly, Matthew; Woodhouse, Iain H.; Niklas, Karl J.; Hammond, Sean T.
2012-01-01
Individual trees have been shown to exhibit strong relationships between DBH, height and volume. Often such studies are cited as justification for forest volume or standing biomass estimation through remote sensing. With resolution of common satellite remote sensing systems generally too low to resolve individuals, and a need for larger coverage, these systems rely on descriptive heights, which account for tree collections in forests. For remote sensing and allometric applications, this height is not entirely understood in terms of its location. Here, a forest growth model (SERA) analyzes forest canopy height relationships with forest wood volume. Maximum height, mean, H100, and Lorey's height are examined for variability under plant number density, resource and species. Our findings, shown to be allometrically consistent with empirical measurements for forested communities world-wide, are analyzed for implications to forest remote sensing techniques such as LiDAR and RADAR. Traditional forestry measures of maximum height, and to a lesser extent H100 and Lorey's, exhibit little consistent correlation with forest volume across modeled conditions. The implication is that using forest height to infer volume or biomass from remote sensing requires species and community behavioral information to infer accurate estimates using height alone. SERA predicts mean height to provide the most consistent relationship with volume of the height classifications studied and overall across forest variations. This prediction agrees with empirical data collected from conifer and angiosperm forests with plant densities ranging between 102–106 plants/hectare and heights 6–49 m. Height classifications investigated are potentially linked to radar scattering centers with implications for allometry. These findings may be used to advance forest biomass estimation accuracy through remote sensing. Furthermore, Lorey's height with its specific relationship to remote sensing physics is recommended as a more universal indicator of volume when using remote sensing than achieved using either maximum height or H100. PMID:22457800
Brolly, Matthew; Woodhouse, Iain H; Niklas, Karl J; Hammond, Sean T
2012-01-01
Individual trees have been shown to exhibit strong relationships between DBH, height and volume. Often such studies are cited as justification for forest volume or standing biomass estimation through remote sensing. With resolution of common satellite remote sensing systems generally too low to resolve individuals, and a need for larger coverage, these systems rely on descriptive heights, which account for tree collections in forests. For remote sensing and allometric applications, this height is not entirely understood in terms of its location. Here, a forest growth model (SERA) analyzes forest canopy height relationships with forest wood volume. Maximum height, mean, H₁₀₀, and Lorey's height are examined for variability under plant number density, resource and species. Our findings, shown to be allometrically consistent with empirical measurements for forested communities world-wide, are analyzed for implications to forest remote sensing techniques such as LiDAR and RADAR. Traditional forestry measures of maximum height, and to a lesser extent H₁₀₀ and Lorey's, exhibit little consistent correlation with forest volume across modeled conditions. The implication is that using forest height to infer volume or biomass from remote sensing requires species and community behavioral information to infer accurate estimates using height alone. SERA predicts mean height to provide the most consistent relationship with volume of the height classifications studied and overall across forest variations. This prediction agrees with empirical data collected from conifer and angiosperm forests with plant densities ranging between 10²-10⁶ plants/hectare and heights 6-49 m. Height classifications investigated are potentially linked to radar scattering centers with implications for allometry. These findings may be used to advance forest biomass estimation accuracy through remote sensing. Furthermore, Lorey's height with its specific relationship to remote sensing physics is recommended as a more universal indicator of volume when using remote sensing than achieved using either maximum height or H₁₀₀.
24 CFR 203.18b - Increased mortgage amount.
Code of Federal Regulations, 2010 CFR
2010-04-01
... include a listing of actual sales prices in the area for all or nearly all new and existing 1-family homes and condominiums, over a period of time varies with sales volume, as follows: (i) For 500 or more... (a) of this section must consist of sufficient housing sales price data for the entire geographic...
Alternative Fuels Data Center: State Alternative Fuel and Advanced Vehicle
2016, the number of new state-level legislative, executive, private, and utility activities related to , new utility and private incentives focused almost entirely on electricity. In previous years, natural gas was also a strong focus area for states. In 2016, however, the volume of new state incentives
Evaluation Methodology. The Evaluation Exchange. Volume 11, Number 2, Summer 2005
ERIC Educational Resources Information Center
Coffman, Julia, Ed.
2005-01-01
This is the third issue of "The Evaluation Exchange" devoted entirely to the theme of methodology, though every issue tries to identify new methodological choices, the instructive ways in which people have applied or combined different methods, and emerging methodological trends. For example, lately "theories of change" have gained almost…
Teaching English Language Learners: Literacy Strategies and Resources for K-6
ERIC Educational Resources Information Center
Xu, Shelley Hong
2010-01-01
Grounded in research and practical expertise, this volume helps K-6 teachers skillfully support all of their English language learners (ELLs)--from a single student to an entire classroom. Ideas for teaching ELLs across different grade and proficiency levels include ways to link instruction to students' lived experiences, use a variety of…
ERIC Educational Resources Information Center
Sanford, Gerlinde Ulm
This document provides a computer-based concordance of the vocabulary used in Friedrich von Schiller's "Aesthetic and Philosophical Writings" as they appear in Volumes 20 and 21 of Schiller's "Werke," 1967 edition, edited by Benno von Wiese. The first section includes the entire text, each sentence numbered for research…
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Half-kernel. 51.1441 Section 51.1441 Agriculture... Standards for Grades of Shelled Pecans Definitions § 51.1441 Half-kernel. Half-kernel means one of the separated halves of an entire pecan kernel with not more than one-eighth of its original volume missing...
ERIC Educational Resources Information Center
EDUTECH Report, 1996
1996-01-01
This document consists of 12 issues, an entire volume year, of the EDUTECH Report published between April 1995 and March 1996. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue typically contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a…
The EDUTECH Report, 2000-2001.
ERIC Educational Resources Information Center
Warger, Thomas, Ed.
2001-01-01
This document consists of 12 issues, an entire volume year, of the EDUTECH Report. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also contain brief…
The EDUTECH Report, 1998-1999.
ERIC Educational Resources Information Center
EDUTECH Report, 1999
1999-01-01
This document consists of 12 issues, an entire volume year, of the EDUTECH Report. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also contain brief…
ERIC Educational Resources Information Center
EDUTECH Report, 1996
1996-01-01
This document consists of 12 issues, an entire volume year, of the EDUTECH Report published between April 1996 and March 1997. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue typically contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a…
The EDUTECH Report, 1999-2000.
ERIC Educational Resources Information Center
EDUTECH Report, 2000
2000-01-01
This document consists of the 12 issues, an entire volume year, of the 1999-2000 EDUTECH Report. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two or three articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also…
Science, Volume 184 Number 4134. Energy.
ERIC Educational Resources Information Center
Abelson, Philip H., Ed.
1974-01-01
This entire issue of the "Science" journal is devoted to the topic of energy and issues relating to the energy crisis. Its content was chosen to present material relevant to important public decisions of the next few years. Twenty-six articles cover a wide range of topics, including the impact of the energy crisis on people and…
40 CFR 1036.150 - Interim provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 17, 2013, § 1036.150 was amended by revising paragraphs (d), (g)(2), and (g)(3), effective Aug. 16... certify your entire U.S.-directed production volume within that averaging set to these standards. This...'s CO2 emissions relative to its 2012 baseline level and certify it to an FCL below the applicable...
Mount Baker lahars and debris flows, ancient, modern, and future
Tucker, David S; Scott, Kevin M.; Grossman, Eric E.; Linneman, Scott
2014-01-01
Holocene lahars and large debris flows (>106 m3) have left recognizable deposits in the Middle Fork Nooksack valley. A debris flow in 2013 resulting from a landslide in a Little Ice Age moraine had an estimated volume of 100,000 m3, yet affected turbidity for the entire length of the river, and produced a slug of sediment that is currently being reworked and remobilized in the river system. Deposits of smaller-volume debris flows, deposited as terraces in the upper valley, may be entirely eroded within a few years. Consequently, the geologic record of small debris flows such as those that occurred in 2013 is probably very fragmentary. Small debris flows may still have significant impacts on hydrology, biology, and human uses of rivers downstream. Impacts include the addition of waves of fine sediment to stream loads, scouring or burying salmon-spawning gravels, forcing unplanned and sudden closure of municipal water intakes, damaging or destroying trail crossings, extending river deltas into estuaries, and adding to silting of harbors near river mouths.
Kinetic energy budgets in areas of convection
NASA Technical Reports Server (NTRS)
Fuelberg, H. E.
1979-01-01
Synoptic scale budgets of kinetic energy are computed using 3 and 6 h data from three of NASA's Atmospheric Variability Experiments (AVE's). Numerous areas of intense convection occurred during the three experiments. Large kinetic energy variability, with periods as short as 6 h, is observed in budgets computed over each entire experiment area and over limited volumes that barely enclose the convection and move with it. Kinetic energy generation and transport processes in the smaller volumes are often a maximum when the enclosed storms are near peak intensity, but the nature of the various energy processes differs between storm cases and seems closely related to the synoptic conditions. A commonly observed energy budget for peak storm intensity indicates that generation of kinetic energy by cross-contour flow is the major energy source while dissipation to subgrid scales is the major sink. Synoptic scale vertical motion transports kinetic energy from lower to upper levels of the atmosphere while low-level horizontal flux convergence and upper-level horizontal divergence also occur. Spatial fields of the energy budget terms show that the storm environment is a major center of energy activity for the entire area.
Subsystems component definitions summary program
NASA Technical Reports Server (NTRS)
Scott, A. Don; Thomas, Carolyn C.; Simonsen, Lisa C.; Hall, John B., Jr.
1991-01-01
A computer program, the Subsystems Component Definitions Summary (SUBCOMDEF), was developed to provide a quick and efficient means of summarizing large quantities of subsystems component data in terms of weight, volume, resupply, and power. The program was validated using Space Station Freedom Program Definition Requirements Document data for the internal and external thermal control subsystem. Once all component descriptions, unit weights and volumes, resupply, and power data are input, the user may obtain a summary report of user-specified portions of the subsystem or of the entire subsystem as a whole. Any combination or all of the parameters of wet and dry weight, wet and dry volume, resupply weight and volume, and power may be displayed. The user may vary the resupply period according to individual mission requirements, as well as the number of hours per day power consuming components operate. Uses of this program are not limited only to subsystem component summaries. Any applications that require quick, efficient, and accurate weight, volume, resupply, or power summaries would be well suited to take advantage of SUBCOMDEF's capabilities.
Fusing literature and full network data improves disease similarity computation.
Li, Ping; Nie, Yaling; Yu, Jingkai
2016-08-30
Identifying relatedness among diseases could help deepen understanding for the underlying pathogenic mechanisms of diseases, and facilitate drug repositioning projects. A number of methods for computing disease similarity had been developed; however, none of them were designed to utilize information of the entire protein interaction network, using instead only those interactions involving disease causing genes. Most of previously published methods required gene-disease association data, unfortunately, many diseases still have very few or no associated genes, which impeded broad adoption of those methods. In this study, we propose a new method (MedNetSim) for computing disease similarity by integrating medical literature and protein interaction network. MedNetSim consists of a network-based method (NetSim), which employs the entire protein interaction network, and a MEDLINE-based method (MedSim), which computes disease similarity by mining the biomedical literature. Among function-based methods, NetSim achieved the best performance. Its average AUC (area under the receiver operating characteristic curve) reached 95.2 %. MedSim, whose performance was even comparable to some function-based methods, acquired the highest average AUC in all semantic-based methods. Integration of MedSim and NetSim (MedNetSim) further improved the average AUC to 96.4 %. We further studied the effectiveness of different data sources. It was found that quality of protein interaction data was more important than its volume. On the contrary, higher volume of gene-disease association data was more beneficial, even with a lower reliability. Utilizing higher volume of disease-related gene data further improved the average AUC of MedNetSim and NetSim to 97.5 % and 96.7 %, respectively. Integrating biomedical literature and protein interaction network can be an effective way to compute disease similarity. Lacking sufficient disease-related gene data, literature-based methods such as MedSim can be a great addition to function-based algorithms. It may be beneficial to steer more resources torward studying gene-disease associations and improving the quality of protein interaction data. Disease similarities can be computed using the proposed methods at http:// www.digintelli.com:8000/ .
Modelling lidar volume-averaging and its significance to wind turbine wake measurements
NASA Astrophysics Data System (ADS)
Meyer Forsting, A. R.; Troldborg, N.; Borraccino, A.
2017-05-01
Lidar velocity measurements need to be interpreted differently than conventional in-situ readings. A commonly ignored factor is “volume-averaging”, which refers to lidars not sampling in a single, distinct point but along its entire beam length. However, especially in regions with large velocity gradients, like the rotor wake, can it be detrimental. Hence, an efficient algorithm mimicking lidar flow sampling is presented, which considers both pulsed and continous-wave lidar weighting functions. The flow-field around a 2.3 MW turbine is simulated using Detached Eddy Simulation in combination with an actuator line to test the algorithm and investigate the potential impact of volume-averaging. Even with very few points discretising the lidar beam is volume-averaging captured accurately. The difference in a lidar compared to a point measurement is greatest at the wake edges and increases from 30% one rotor diameter (D) downstream of the rotor to 60% at 3D.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merchant, Thomas E.; Kun, Larry E.; Krasin, Matthew J.
2008-03-01
Purpose: Limiting the neurocognitive sequelae of radiotherapy (RT) has been an objective in the treatment of medulloblastoma. Conformal RT to less than the entire posterior fossa (PF) after craniospinal irradiation might reduce neurocognitive sequelae and requires evaluation. Methods and Materials: Between October 1996 and August 2003, 86 patients, 3-21 years of age, with newly diagnosed, average-risk medulloblastoma were treated in a prospective, institutional review board-approved, multi-institution trial of risk-adapted RT and dose-intensive chemotherapy. RT began within 28 days of definitive surgery and consisted of craniospinal irradiation (23.4 Gy), conformal PF RT (36.0 Gy), and primary site RT (55.8 Gy). Themore » planning target volume for the primary site included the postoperative tumor bed surrounded by an anatomically confined margin of 2 cm that was then expanded with a geometric margin of 0.3-0.5 cm. Chemotherapy was initiated 6 weeks after RT and included four cycles of high-dose cyclophosphamide, cisplatin, and vincristine. Results: At a median follow-up of 61.2 months (range, 5.2-115.0 months), the estimated 5-year event-free survival and cumulative incidence of PF failure rate was 83.0% {+-} 5.3% and 4.9% {+-} 2.4% ({+-} standard error), respectively. The targeting guidelines used in this study resulted in a mean reduction of 13% in the volume of the PF receiving doses >55 Gy compared with conventionally planned RT. The reductions in the dose to the temporal lobes, cochleae, and hypothalamus were statistically significant. Conclusion: This prospective trial has demonstrated that irradiation of less than the entire PF after 23.4 Gy craniospinal irradiation for average-risk medulloblastoma results in disease control comparable to that after treatment of the entire PF.« less
Storsve, Andreas B; Fjell, Anders M; Tamnes, Christian K; Westlye, Lars T; Overbye, Knut; Aasland, Hilde W; Walhovd, Kristine B
2014-06-18
Human cortical thickness and surface area are genetically independent, emerge through different neurobiological events during development, and are sensitive to different clinical conditions. However, the relationship between changes in the two over time is unknown. Additionally, longitudinal studies have almost invariably been restricted to older adults, precluding the delineation of adult life span trajectories of change in cortical structure. In this longitudinal study, we investigated changes in cortical thickness, surface area, and volume after an average interval of 3.6 years in 207 well screened healthy adults aged 23-87 years. We hypothesized that the relationships among metrics are dynamic across the life span, that the primary contributor to cortical volume reductions in aging is cortical thinning, and that magnitude of change varies with age and region. Changes over time were seen in cortical area (mean annual percentage change [APC], -0.19), thickness (APC, -0.35), and volume (APC, -0.51) in most regions. Volume changes were primarily explained by changes in thickness rather than area. A negative relationship between change in thickness and surface area was found across several regions, where more thinning was associated with less decrease in area, and vice versa. Accelerating changes with increasing age was seen in temporal and occipital cortices. In contrast, decelerating changes were seen in prefrontal and anterior cingulate cortices. In conclusion, a dynamic relationship between cortical thickness and surface area changes exists throughout the adult life span. The mixture of accelerating and decelerating changes further demonstrates the importance of studying these metrics across the entire adult life span. Copyright © 2014 the authors 0270-6474/14/348488-11$15.00/0.
Schrader, I; Wilk, D; Jansen, O; Riedel, C
2013-09-01
To evaluate how accurately final infarct volume in acute ischemic stroke can be predicted with perfusion CT (PCT) using a 64-MDCT unit and the toggling table technique. Retrospective analysis of 89 patients with acute ischemic stroke who underwent CCT, CT angiography (CTA) and PCT using the "toggling table" technique within the first three hours after symptom onset. In patients with successful thrombolytic therapy (n = 48) and in those without effective thrombolytic therapy (n = 41), the infarct volume and the volume of the penumbra on PCT were compared to the infarct size on follow-up images (CT or MRI) performed within 8 days. The feasibility of complete infarct volume prediction by 8 cm cranio-caudal coverage was evaluated. The correlation between the volume of hypoperfusion on PCT defined by cerebral blood volume reduction and final infarct volume was strongest in patients with successful thrombolytic therapy with underestimation of the definite infarct volume by 8.5 ml on average. The CBV map had the greatest prognostic value. In patients without successful thrombolytic therapy, the final infarct volume was overestimated by 12.1 ml compared to the MTT map on PCT. All infarcts were detected completely. There were no false-positive or false-negative results. Using PCT and the "toggling table" technique in acute stroke patients is helpful for the rapid and accurate quantification of the minimal final infarct and is therefore a prognostic parameter which has to be evaluated in further studies to assess its impact on therapeutic decision. ▶ Using PCT and the “toggling table technique” allows accurate quantification of the infarct core and penumbra. ▶ It is possible to record dynamic perfusion parameters quickly and easily of almost the entire supratentorial brain volume on a 64-slice MDCT unit. ▶ The technique allows identification of those patients who could profit from thrombolytic therapy outside the established time intervals. © Georg Thieme Verlag KG Stuttgart · New York.
Geometric optimization of thermal systems
NASA Astrophysics Data System (ADS)
Alebrahim, Asad Mansour
2000-10-01
The work in chapter 1 extends to three dimensions and to convective heat transfer the constructal method of minimizing the thermal resistance between a volume and one point. In the first part, the heat flow mechanism is conduction, and the heat generating volume is occupied by low conductivity material (k 0) and high conductivity inserts (kp) that are shaped as constant-thickness disks mounted on a common stem of kp material. In the second part the interstitial spaces once occupied by k0 material are bathed by forced convection. The internal and external geometric aspect ratios of the elemental volume and the first assembly are optimized numerically subject to volume constraints. Chapter 2 presents the constrained thermodynamic optimization of a cross-flow heat exchanger with ram air on the cold side, which is used in the environmental control systems of aircraft. Optimized geometric features such as the ratio of channel spacings and flow lengths are reported. It is found that the optimized features are relatively insensitive to changes in other physical parameters of the installation and relatively insensitive to the additional irreversibility due to discharging the ram-air stream into the atmosphere, emphasizing the robustness of the thermodynamic optimum. In chapter 3 the problem of maximizing exergy extraction from a hot stream by distributing streams over a heat transfer surface is studied. In the first part, the cold stream is compressed in an isothermal compressor, expanded in an adiabatic turbine, and discharged into the ambient. In the second part, the cold stream is compressed in an adiabatic compressor. Both designs are optimized with respect to the capacity-rate imbalance of the counter-flow and the pressure ratio maintained by the compressor. This study shows the tradeoff between simplicity and increased performance, and outlines the path for further conceptual work on the extraction of exergy from a hot stream that is being cooled gradually. The aim of chapter 4 was to optimize the performance of a boot-strap air cycle of an environmental control system (ECS) for aircraft. New in the present study was that the optimization refers to the performance of the entire ECS system, not to the performance of an individual component. Also, there were two heat exchangers, not one, and their relative positions and sizes were not specified in advance. This study showed that geometric optimization can be identified when the optimization procedure refers to the performance of the entire ECS system, not to the performance of an individual component. This optimized features were robust relative to some physical parameters. This robustness may be used to simplify future optimization of similar systems.
Water storage capacity of natural wetland depressions in the Devils Lake basin of North Dakota
Ludden, A.P.; Frink, D.L.; Johnson, D.H.
1983-01-01
Photogrammetric mapping techniques were used to derive the water storage capacities of natural wetland depressions other than lakes in the Devils Lake Basin of North Dakota. Results from sample quarter-section areas were expanded to the entire basin. Depressions in the Devils Lake Basin have a maximum storage capacity of nearly 811,000 cubic dekameters (657,000 acre-feet). The depressions store about 72 percent of the total runoff volume from a 2-year-frequency runoff and about 41 percent of the total runoff volume from a 100-year-frequency runoff.
MRI-based treatment planning with pseudo CT generated through atlas registration.
Uh, Jinsoo; Merchant, Thomas E; Li, Yimei; Li, Xingyu; Hua, Chiaho
2014-05-01
To evaluate the feasibility and accuracy of magnetic resonance imaging (MRI)-based treatment planning using pseudo CTs generated through atlas registration. A pseudo CT, providing electron density information for dose calculation, was generated by deforming atlas CT images previously acquired on other patients. The authors tested 4 schemes of synthesizing a pseudo CT from single or multiple deformed atlas images: use of a single arbitrarily selected atlas, arithmetic mean process using 6 atlases, and pattern recognition with Gaussian process (PRGP) using 6 or 12 atlases. The required deformation for atlas CT images was derived from a nonlinear registration of conjugated atlas MR images to that of the patient of interest. The contrasts of atlas MR images were adjusted by histogram matching to reduce the effect of different sets of acquisition parameters. For comparison, the authors also tested a simple scheme assigning the Hounsfield unit of water to the entire patient volume. All pseudo CT generating schemes were applied to 14 patients with common pediatric brain tumors. The image similarity of real patient-specific CT and pseudo CTs constructed by different schemes was compared. Differences in computation times were also calculated. The real CT in the treatment planning system was replaced with the pseudo CT, and the dose distribution was recalculated to determine the difference. The atlas approach generally performed better than assigning a bulk CT number to the entire patient volume. Comparing atlas-based schemes, those using multiple atlases outperformed the single atlas scheme. For multiple atlas schemes, the pseudo CTs were similar to the real CTs (correlation coefficient, 0.787-0.819). The calculated dose distribution was in close agreement with the original dose. Nearly the entire patient volume (98.3%-98.7%) satisfied the criteria of chi-evaluation (<2% maximum dose and 2 mm range). The dose to 95% of the volume and the percentage of volume receiving at least 95% of the prescription dose in the planning target volume differed from the original values by less than 2% of the prescription dose (root-mean-square, RMS < 1%). The PRGP scheme did not perform better than the arithmetic mean process with the same number of atlases. Increasing the number of atlases from 6 to 12 often resulted in improvements, but statistical significance was not always found. MRI-based treatment planning with pseudo CTs generated through atlas registration is feasible for pediatric brain tumor patients. The doses calculated from pseudo CTs agreed well with those from real CTs, showing dosimetric accuracy within 2% for the PTV when multiple atlases were used. The arithmetic mean process may be a reasonable choice over PRGP for the synthesis scheme considering performance and computational costs.
MRI-based treatment planning with pseudo CT generated through atlas registration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uh, Jinsoo, E-mail: jinsoo.uh@stjude.org; Merchant, Thomas E.; Hua, Chiaho
2014-05-15
Purpose: To evaluate the feasibility and accuracy of magnetic resonance imaging (MRI)-based treatment planning using pseudo CTs generated through atlas registration. Methods: A pseudo CT, providing electron density information for dose calculation, was generated by deforming atlas CT images previously acquired on other patients. The authors tested 4 schemes of synthesizing a pseudo CT from single or multiple deformed atlas images: use of a single arbitrarily selected atlas, arithmetic mean process using 6 atlases, and pattern recognition with Gaussian process (PRGP) using 6 or 12 atlases. The required deformation for atlas CT images was derived from a nonlinear registration ofmore » conjugated atlas MR images to that of the patient of interest. The contrasts of atlas MR images were adjusted by histogram matching to reduce the effect of different sets of acquisition parameters. For comparison, the authors also tested a simple scheme assigning the Hounsfield unit of water to the entire patient volume. All pseudo CT generating schemes were applied to 14 patients with common pediatric brain tumors. The image similarity of real patient-specific CT and pseudo CTs constructed by different schemes was compared. Differences in computation times were also calculated. The real CT in the treatment planning system was replaced with the pseudo CT, and the dose distribution was recalculated to determine the difference. Results: The atlas approach generally performed better than assigning a bulk CT number to the entire patient volume. Comparing atlas-based schemes, those using multiple atlases outperformed the single atlas scheme. For multiple atlas schemes, the pseudo CTs were similar to the real CTs (correlation coefficient, 0.787–0.819). The calculated dose distribution was in close agreement with the original dose. Nearly the entire patient volume (98.3%–98.7%) satisfied the criteria of chi-evaluation (<2% maximum dose and 2 mm range). The dose to 95% of the volume and the percentage of volume receiving at least 95% of the prescription dose in the planning target volume differed from the original values by less than 2% of the prescription dose (root-mean-square, RMS < 1%). The PRGP scheme did not perform better than the arithmetic mean process with the same number of atlases. Increasing the number of atlases from 6 to 12 often resulted in improvements, but statistical significance was not always found. Conclusions: MRI-based treatment planning with pseudo CTs generated through atlas registration is feasible for pediatric brain tumor patients. The doses calculated from pseudo CTs agreed well with those from real CTs, showing dosimetric accuracy within 2% for the PTV when multiple atlases were used. The arithmetic mean process may be a reasonable choice over PRGP for the synthesis scheme considering performance and computational costs.« less
MRI-based treatment planning with pseudo CT generated through atlas registration
Uh, Jinsoo; Merchant, Thomas E.; Li, Yimei; Li, Xingyu; Hua, Chiaho
2014-01-01
Purpose: To evaluate the feasibility and accuracy of magnetic resonance imaging (MRI)-based treatment planning using pseudo CTs generated through atlas registration. Methods: A pseudo CT, providing electron density information for dose calculation, was generated by deforming atlas CT images previously acquired on other patients. The authors tested 4 schemes of synthesizing a pseudo CT from single or multiple deformed atlas images: use of a single arbitrarily selected atlas, arithmetic mean process using 6 atlases, and pattern recognition with Gaussian process (PRGP) using 6 or 12 atlases. The required deformation for atlas CT images was derived from a nonlinear registration of conjugated atlas MR images to that of the patient of interest. The contrasts of atlas MR images were adjusted by histogram matching to reduce the effect of different sets of acquisition parameters. For comparison, the authors also tested a simple scheme assigning the Hounsfield unit of water to the entire patient volume. All pseudo CT generating schemes were applied to 14 patients with common pediatric brain tumors. The image similarity of real patient-specific CT and pseudo CTs constructed by different schemes was compared. Differences in computation times were also calculated. The real CT in the treatment planning system was replaced with the pseudo CT, and the dose distribution was recalculated to determine the difference. Results: The atlas approach generally performed better than assigning a bulk CT number to the entire patient volume. Comparing atlas-based schemes, those using multiple atlases outperformed the single atlas scheme. For multiple atlas schemes, the pseudo CTs were similar to the real CTs (correlation coefficient, 0.787–0.819). The calculated dose distribution was in close agreement with the original dose. Nearly the entire patient volume (98.3%–98.7%) satisfied the criteria of chi-evaluation (<2% maximum dose and 2 mm range). The dose to 95% of the volume and the percentage of volume receiving at least 95% of the prescription dose in the planning target volume differed from the original values by less than 2% of the prescription dose (root-mean-square, RMS < 1%). The PRGP scheme did not perform better than the arithmetic mean process with the same number of atlases. Increasing the number of atlases from 6 to 12 often resulted in improvements, but statistical significance was not always found. Conclusions: MRI-based treatment planning with pseudo CTs generated through atlas registration is feasible for pediatric brain tumor patients. The doses calculated from pseudo CTs agreed well with those from real CTs, showing dosimetric accuracy within 2% for the PTV when multiple atlases were used. The arithmetic mean process may be a reasonable choice over PRGP for the synthesis scheme considering performance and computational costs. PMID:24784377
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akimoto, Tetsuo; Katoh, Hiroyuki; Kitamoto, Yoshizumi
2006-06-01
Purpose: To evaluate the incidence of Grade 2 or worse rectal bleeding after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiotherapy (EBRT), with special emphasis on the relationship between the incidence of rectal bleeding and the rectal dose from HDR brachytherapy. Methods and Materials: The records of 100 patients who were treated by HDR brachytherapy combined with EBRT for {>=}12 months were analyzed. The fractionation schema for HDR brachytherapy was prospectively changed, and the total radiation dose for EBRT was fixed at 51 Gy. The distribution of the fractionation schema used in the patients was as follows: 5 Gy xmore » 5 in 13 patients; 7 Gy x 3 in 19 patients; and 9 Gy x 2 in 68 patients. Results: Ten patients (10%) developed Grade 2 or worse rectal bleeding. Regarding the correlation with dosimetric factors, no significant differences were found in the average percentage of the entire rectal volume receiving 30%, 50%, 80%, and 90% of the prescribed radiation dose from EBRT between those with bleeding and those without. The average percentage of the entire rectal volume receiving 10%, 30%, 50%, 80%, and 90% of the prescribed radiation dose from HDR brachytherapy in those who developed rectal bleeding was 77.9%, 28.6%, 9.0%, 1.5%, and 0.3%, respectively, and was 69.2%, 22.2%, 6.6%, 0.9%, and 0.4%, respectively, in those without bleeding. The differences in the percentages of the entire rectal volume receiving 10%, 30%, and 50% between those with and without bleeding were statistically significant. Conclusions: The rectal dose from HDR brachytherapy for patients with prostate cancer may have a significant impact on the incidence of Grade 2 or worse rectal bleeding.« less
The whole-brain N-acetylaspartate correlates with education in normal adults.
Glodzik, Lidia; Wu, William E; Babb, James S; Achtnichts, Lutz; Amann, Michael; Sollberger, Marc; Monsch, Andreas U; Gass, Achim; Gonen, Oded
2012-10-30
N-acetylaspartate (NAA) is an index of neuronal integrity. We hypothesized that in healthy subjects its whole brain concentration (WBNAA) may be related to formal educational attainment, a common proxy for cognitive reserve. To test this hypothesis, 97 middle aged to elderly subjects (51-89 years old, 38% women) underwent brain magnetic resonance imaging and non-localizing proton spectroscopy. Their WBNAA was obtained by dividing their whole-head NAA amount by the brain volume. Intracranial volume and fractional brain volume, a metric of brain atrophy, were also determined. Each subject's educational attainment was the sum of his/her years of formal education. In the entire group higher education was associated with larger intracranial volume. The relationship between WBNAA and education was observed only in younger (51-70 years old) participants. In this group, education explained 21% of the variance in WBNAA. More WBNAA was related to more years of formal education in adults and younger elders. Prospective studies can determine whether this relationship reflects a true advantage from years of training versus innate characteristics predisposing a subject to higher achievements later in life. We propose that late-life WBNAA may be more affected by other factors acting at midlife and later. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Emission characteristics of plasma based on xenon-rubidium bromide mixture
NASA Astrophysics Data System (ADS)
Heneral, A. A.; Avtaeva, S. V.
2017-10-01
Luminescence spectra of a longitudinal pulse-periodic discharge in xenon mixture with rubidium bromide vapors (Xe-RbBr) are studied experimentally at low pressures. The conditions leading to the appearance of intense bands of ultraviolet radiation of exciplex XeBr* molecules in the spectral interval between 200 and 400 nm are found. The highest yield of UV radiation of XeBr* molecules is achieved when the temperature of discharge-tube walls is equal to 750°C. A maximum power of UV radiation from the entire plasma volume as high as 4.8 W is obtained.
NASA Technical Reports Server (NTRS)
1984-01-01
Automation reuirements were developed for two manufacturing concepts: (1) Gallium Arsenide Electroepitaxial Crystal Production and Wafer Manufacturing Facility, and (2) Gallium Arsenide VLSI Microelectronics Chip Processing Facility. A functional overview of the ultimate design concept incoporating the two manufacturing facilities on the space station are provided. The concepts were selected to facilitate an in-depth analysis of manufacturing automation requirements in the form of process mechanization, teleoperation and robotics, sensors, and artificial intelligence. While the cost-effectiveness of these facilities was not analyzed, both appear entirely feasible for the year 2000 timeframe.
Data on the mixing of non-Newtonian fluids by a Rushton turbine in a cylindrical tank.
Khapre, Akhilesh; Munshi, Basudeb
2016-09-01
The paper focuses on the data collected from the mixing of shear thinning non-Newtonian fluids in a cylindrical tank by a Rushton turbine. The data presented are obtained by using Computational Fluid Dynamics (CFD) simulation of fluid flow field in the entire tank volume. The CFD validation data for this study is reported in the research article 'Numerical investigation of hydrodynamic behavior of shear thinning fluids in stirred tank' (Khapre and Munshi, 2015) [1]. The tracer injection method is used for the prediction of mixing time and mixing efficiency of a Rushton turbine impeller.
Chang, Sung-A; Lee, Sang-Chol; Kim, Eun-Young; Hahm, Seung-Hee; Jang, Shin Yi; Park, Sung-Ji; Choi, Jin-Oh; Park, Seung Woo; Choe, Yeon Hyeon; Oh, Jae K
2011-08-01
With recent developments in echocardiographic technology, a new system using real-time three-dimensional echocardiography (RT3DE) that allows single-beat acquisition of the entire volume of the left ventricle and incorporates algorithms for automated border detection has been introduced. Provided that these techniques are acceptably reliable, three-dimensional echocardiography may be much more useful for clinical practice. The aim of this study was to evaluate the feasibility and accuracy of left ventricular (LV) volume measurements by RT3DE using the single-beat full-volume capture technique. One hundred nine consecutive patients scheduled for cardiac magnetic resonance imaging and RT3DE using the single-beat full-volume capture technique on the same day were recruited. LV end-systolic volume, end-diastolic volume, and ejection fraction were measured using an auto-contouring algorithm from data acquired on RT3DE. The data were compared with the same measurements obtained using cardiac magnetic resonance imaging. Volume measurements on RT3DE with single-beat full-volume capture were feasible in 84% of patients. Both interobserver and intraobserver variability of three-dimensional measurements of end-systolic and end-diastolic volumes showed excellent agreement. Pearson's correlation analysis showed a close correlation of end-systolic and end-diastolic volumes between RT3DE and cardiac magnetic resonance imaging (r = 0.94 and r = 0.91, respectively, P < .0001 for both). Bland-Altman analysis showed reasonable limits of agreement. After application of the auto-contouring algorithm, the rate of successful auto-contouring (cases requiring minimal manual corrections) was <50%. RT3DE using single-beat full-volume capture is an easy and reliable technique to assess LV volume and systolic function in clinical practice. However, the image quality and low frame rate still limit its application for dilated left ventricles, and the automated volume analysis program needs more development to make it clinically efficacious. Copyright © 2011 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
3D geometric split-merge segmentation of brain MRI datasets.
Marras, Ioannis; Nikolaidis, Nikolaos; Pitas, Ioannis
2014-05-01
In this paper, a novel method for MRI volume segmentation based on region adaptive splitting and merging is proposed. The method, called Adaptive Geometric Split Merge (AGSM) segmentation, aims at finding complex geometrical shapes that consist of homogeneous geometrical 3D regions. In each volume splitting step, several splitting strategies are examined and the most appropriate is activated. A way to find the maximal homogeneity axis of the volume is also introduced. Along this axis, the volume splitting technique divides the entire volume in a number of large homogeneous 3D regions, while at the same time, it defines more clearly small homogeneous regions within the volume in such a way that they have greater probabilities of survival at the subsequent merging step. Region merging criteria are proposed to this end. The presented segmentation method has been applied to brain MRI medical datasets to provide segmentation results when each voxel is composed of one tissue type (hard segmentation). The volume splitting procedure does not require training data, while it demonstrates improved segmentation performance in noisy brain MRI datasets, when compared to the state of the art methods. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Thibodeau, Eric; Gheribi, Aimen E.; Jung, In-Ho
2016-04-01
A structural molar volume model was developed to accurately reproduce the molar volume of molten oxides. As the non-linearity of molar volume is related to the change in structure of molten oxides, the silicate tetrahedral Q-species, calculated from the modified quasichemical model with an optimized thermodynamic database, were used as basic structural units in the present model. Experimental molar volume data for unary and binary melts in the Li2O-Na2O-K2O-MgO-CaO-MnO-PbO-Al2O3-SiO2 system were critically evaluated. The molar volumes of unary oxide components and binary Q-species, which are model parameters of the present structural model, were determined to accurately reproduce the experimental data across the entire binary composition in a wide range of temperatures. The non-linear behavior of molar volume and thermal expansivity of binary melt depending on SiO2 content are well reproduced by the present model.
Volumetric Spectroscopic Imaging of Glioblastoma Multiforme Radiation Treatment Volumes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parra, N. Andres; Maudsley, Andrew A.; Gupta, Rakesh K.
Purpose: Magnetic resonance (MR) imaging and computed tomography (CT) are used almost exclusively in radiation therapy planning of glioblastoma multiforme (GBM), despite their well-recognized limitations. MR spectroscopic imaging (MRSI) can identify biochemical patterns associated with normal brain and tumor, predominantly by observation of choline (Cho) and N-acetylaspartate (NAA) distributions. In this study, volumetric 3-dimensional MRSI was used to map these compounds over a wide region of the brain and to evaluate metabolite-defined treatment targets (metabolic tumor volumes [MTV]). Methods and Materials: Volumetric MRSI with effective voxel size of ∼1.0 mL and standard clinical MR images were obtained from 19 GBM patients.more » Gross tumor volumes and edema were manually outlined, and clinical target volumes (CTVs) receiving 46 and 60 Gy were defined (CTV{sub 46} and CTV{sub 60}, respectively). MTV{sub Cho} and MTV{sub NAA} were constructed based on volumes with high Cho and low NAA relative to values estimated from normal-appearing tissue. Results: The MRSI coverage of the brain was between 70% and 76%. The MTV{sub NAA} were almost entirely contained within the edema, and the correlation between the 2 volumes was significant (r=0.68, P=.001). In contrast, a considerable fraction of MTV{sub Cho} was outside of the edema (median, 33%) and for some patients it was also outside of the CTV{sub 46} and CTV{sub 60}. These untreated volumes were greater than 10% for 7 patients (37%) in the study, and on average more than one-third (34.3%) of the MTV{sub Cho} for these patients were outside of CTV{sub 60}. Conclusions: This study demonstrates the potential usefulness of whole-brain MRSI for radiation therapy planning of GBM and revealed that areas of metabolically active tumor are not covered by standard RT volumes. The described integration of MTV into the RT system will pave the way to future clinical trials investigating outcomes in patients treated based on metabolic information.« less
Ng, Manwa L; Yan, Nan; Chan, Venus; Chen, Yang; Lam, Paul K Y
2018-06-28
Previous studies of the laryngectomized vocal tract using formant frequencies reported contradictory findings. Imagining studies of the vocal tract in alaryngeal speakers are limited due to the possible radiation effect as well as the cost and time associated with the studies. The present study examined the vocal tract configuration of laryngectomized individuals using acoustic reflection technology. Thirty alaryngeal and 30 laryngeal male speakers of Cantonese participated in the study. A pharyngometer was used to obtain volumetric information of the vocal tract. All speakers were instructed to imitate the production of /a/ when the length and volume information of the oral cavity, pharyngeal cavity, and the entire vocal tract were obtained. The data of alaryngeal and laryngeal speakers were compared. Pharyngometric measurements revealed no significant difference in the vocal tract dimensions between laryngeal and alaryngeal speakers. Despite the removal of the larynx and a possible alteration in the pharyngeal cavity during total laryngectomy, the vocal tract configuration (length and volume) in laryngectomized individuals was not significantly different from laryngeal speakers. It is suggested that other factors might have affected formant measures in previous studies. © 2018 S. Karger AG, Basel.
Endovascular Management of Delayed Complete Graft Thrombosis After Endovascular Aneurysm Repair
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thurley, Peter D., E-mail: pthurley@doctors.org.u; Glasby, Michael J.; Pollock, John G.
2010-08-15
Graft thrombosis rates after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms vary widely in published series. When thrombosis does occur, it usually involves a single limb and occurs within 3 months of stent-graft insertion. If the entire endoprosthesis is thrombosed, treatment may be challenging because femoro-femoral crossover graft insertion is not an option and a greater volume of thrombus is present, thus making thrombolysis more difficult. We present two cases of delayed thrombosis after EVAR involving the entire stent-graft. These were successfully treated by a combined surgical and endovascular technique, and patency has been maintained in both cases tomore » date.« less
Clare, Bevin A; Conroy, Richard S; Spelman, Kevin
2009-08-01
Taraxacum officinale (L.) Weber (Asteraceae) has been extensively employed as a diuretic in traditional folk medicine and in modern phytotherapy in Europe, Asia, and the Americas without prior clinical trial substantiation. In this pilot study, a high-quality fresh leaf hydroethanolic extract of the medicinal plant T. officinale (dandelion) was ingested by volunteers to investigate whether an increased urinary frequency and volume would result. Volume of urinary output and fluid intake were recorded by subjects. Baseline values for urinary frequency and excretion ratio (urination volume:fluid intake) were established 2 days prior to dandelion dosing (8 mL TID) and monitored throughout a 1-day dosing period and 24 hours postdosing. For the entire population (n = 17) there was a significant (p < 0.05) increase in the frequency of urination in the 5-hour period after the first dose. There was also a significant (p < 0.001) increase in the excretion ratio in the 5-hour period after the second dose of extract. The third dose failed to change any of the measured parameters. Based on these first human data, T. officinale ethanolic extract shows promise as a diuretic in humans. Further studies are needed to establish the value of this herb for induction of diuresis in human subjects.
1994-06-01
Defense Systems Management requirements for program executive College (DSMC). However. the sec- officers ( PEas ), program managers ond and third sets have...and presenting in- predictable outcomes in terms of cul- formation would change the entire tural change. t4 of culture. Once, carrier pigeons took days
Point-Sampling and Line-Sampling Probability Theory, Geometric Implications, Synthesis
L.R. Grosenbaugh
1958-01-01
Foresters concerned with measuring tree populations on definite areas have long employed two well-known methods of representative sampling. In list or enumerative sampling the entire tree population is tallied with a known proportion being randomly selected and measured for volume or other variables. In area sampling all trees on randomly located plots or strips...
1988-08-01
primitive model would be unthinkable. Similarly, while human operators once made plugboard connections to complete telephone circuits for long-distance...calls, the current volume of U.S. long-distance telephone traffic could not be serviced if the entire U.S. population sat before telephone plugboards
Update: Applications of Research in Music Education Yearbook. Volume 24
ERIC Educational Resources Information Center
Rowman & Littlefield Education, 2006
2006-01-01
Readers of the online journal "Update: Applications of Research in Music Education" who prefer a printed copy of articles most relevant to their work will find them in the new 2005-2006 "Update Yearbook." Now available to everyone interested in the latest music education trends, the Yearbook contains in print the entire online issues for…
Forest resources of the eastern Ozark Region in Missouri
The Forest Survey Organization Central States Forest Experiment Station
1948-01-01
This Survey Release presents the more significant statistics on forest area and timber volume in 14 counties in the Eastern Ozark region of Missouri. As soon as statistical tabulations have been completed other releases will be issued giving similar information for the other important subdivisions of the State. Later an analytical report for the entire State will be...
Forest resources of the Riverborder region in Missouri
The Forest Survey Organization Central States Forest Experiment Station
1948-01-01
This Survey Release presents the more significant statistics on forest area and timber volume in the Riverborder region of eastern Missouri. Similar releases have been issued for the other forest regions of the State. A summary release giving similar data for the entire State will be published shortly. Later an analytical report for the State will be published, which...
Federal Juvenile Delinquency Programs: First Analysis and Evaluation. Volumes One and Two.
ERIC Educational Resources Information Center
National Inst. for Juvenile Justice and Delinquency Prevention (Dept. of Justice/LEAA), Washington, DC.
This publication outlines the activities of the Office of Juvenile Justice since its creation. It also reports on the entire Federal effort in delinquency prevention and juvenile justice. An introductory section describes the history and purpose of the Juvenile Justice and Delinquency Prevention Act of 1974 (Public Law 93-415). Other sections…
Scholarly Publishing: Books, Journals, Publishers, and Libraries in the Twentieth Century.
ERIC Educational Resources Information Center
Abel, Richard E., Ed.; Newlin, Lyman W., Ed.
2002-01-01
In this volume, publishers, booksellers, journal dealers, and librarians share their views on libraries and publishing. While the information/knowledge transfer process in the entire span of the twentieth century was to be addressed by the contributors, the principal focus of every author was to be the last five decades in which the most profound,…
Textos y gramatica del Pima Bajo (Texts and Grammar of the Lower Pima).
ERIC Educational Resources Information Center
Escalante, Roberto H.; Fernandez, Zarina Estrada
This volume, entirely in Spanish and Pima, presents extensive descriptive information about the language spoken by the Pima of Mexico. An introductory chapter reviews the history of research on the language. The second and third chapters explain its phonology and morphology. In the fourth chapter, a number of oral histories and ethnographic texts…
Study of intermolecular interactions in binary mixtures of ethanol in methanol
NASA Astrophysics Data System (ADS)
Maharolkar, Aruna P.; Khirade, P. W.; Murugkar, A. G.
2016-05-01
Present paper deals with study of physicochemical properties like viscosity, density and refractive index for the binary mixtures of ethanol and methanol over the entire concentration range were measured at 298.15 K. The experimental data further used to determine the excess properties viz. excess molar volume, excess viscosity, excess molar refraction. The values of excess properties further fitted with Redlich-Kister (R-K Fit) equation to calculate the binary coefficients and standard deviation. The resulting excess parameters are used to indicate the presence of intermolecular interactions and strength of intermolecular interactions between the molecules in the binary mixtures. Excess parameters indicate structure making factor in the mixture predominates in the system.
Initial parametric study of the flammability of plume releases in Hanford waste tanks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antoniak, Z.I.; Recknagle, K.P.
This study comprised systematic analyses of waste tank headspace flammability following a plume-type of gas release from the waste. First, critical parameters affecting plume flammability were selected, evaluated, and refined. As part of the evaluation the effect of ventilation (breathing) air inflow on the convective flow field inside the tank headspace was assessed, and the magnitude of the so-called {open_quotes}numerical diffusion{close_quotes} on numerical simulation accuracy was investigated. Both issues were concluded to be negligible influences on predicted flammable gas concentrations in the tank headspace. Previous validation of the TEMPEST code against experimental data is also discussed, with calculated results inmore » good agreements with experimental data. Twelve plume release simulations were then run, using release volumes and flow rates that were thought to cover the range of actual release volumes and rates. The results indicate that most plume-type releases remain flammable only during the actual release ends. Only for very large releases representing a significant fraction of the volume necessary to make the entire mixed headspace flammable (many thousands of cubic feet) can flammable concentrations persist for several hours after the release ends. However, as in the smaller plumes, only a fraction of the total release volume is flammable at any one time. The transient evolution of several plume sizes is illustrated in a number of color contour plots that provide insight into plume mixing behavior.« less
Developing a stochastic traffic volume prediction model for public-private partnership projects
NASA Astrophysics Data System (ADS)
Phong, Nguyen Thanh; Likhitruangsilp, Veerasak; Onishi, Masamitsu
2017-11-01
Transportation projects require an enormous amount of capital investment resulting from their tremendous size, complexity, and risk. Due to the limitation of public finances, the private sector is invited to participate in transportation project development. The private sector can entirely or partially invest in transportation projects in the form of Public-Private Partnership (PPP) scheme, which has been an attractive option for several developing countries, including Vietnam. There are many factors affecting the success of PPP projects. The accurate prediction of traffic volume is considered one of the key success factors of PPP transportation projects. However, only few research works investigated how to predict traffic volume over a long period of time. Moreover, conventional traffic volume forecasting methods are usually based on deterministic models which predict a single value of traffic volume but do not consider risk and uncertainty. This knowledge gap makes it difficult for concessionaires to estimate PPP transportation project revenues accurately. The objective of this paper is to develop a probabilistic traffic volume prediction model. First, traffic volumes were estimated following the Geometric Brownian Motion (GBM) process. Monte Carlo technique is then applied to simulate different scenarios. The results show that this stochastic approach can systematically analyze variations in the traffic volume and yield more reliable estimates for PPP projects.
Thorne, M; Salt, A N; DeMott, J E; Henson, M M; Henson, O W; Gewalt, S L
1999-10-01
To establish the dimensions and volumes of the cochlear fluid spaces. Fluid space volumes, lengths, and cross-sectional areas were derived for the cochleas from six species: human, guinea pig, bat, rat, mouse, and gerbil. Three-dimensional reconstructions of the fluid spaces were made from magnetic resonance microscopy (MRM) images. Consecutive serial slices composed of isotropic voxels (25 microm3) representing the entire volume of fixed, isolated cochleas were obtained. The boundaries delineating the fluid spaces, including Reissner's membrane, were resolved for all specimens, except for the human, in which Reissner's membrane was not consistently resolved. Three-dimensional reconstructions of the endolymphatic and perilymphatic fluid spaces were generated. Fluid space length and variation of cross-sectional area with distance were derived by an algorithm that followed the midpoint of the space along the length of the spiral. The total volume of each fluid space was derived from a voxel count for each specimen. Length, volume, and cross-sectional areas are provided for six species. In all cases, the length of the endolymphatic fluid space was consistently longer than that of either perilymphatic scala, primarily as a result of a greater radius of curvature. For guinea pig specimens, the measured volumes of the fluid spaces were considerably lower than those suggested by previous reports based on histological data. The quantification of cochlear fluid spaces provided by this study will enable the more accurate calculation of drug and other solute movements in fluids of the inner ear during experimental or clinical manipulations.
Impact of gastric filling on radiation dose delivered to gastroesophageal junction tumors.
Bouchard, Myriam; McAleer, Mary Frances; Starkschall, George
2010-05-01
This study examined the impact of gastric filling variation on target coverage of gastroesophageal junction (GEJ) tumors in three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), or IMRT with simultaneous integrated boost (IMRT-SIB) plans. Eight patients previously receiving radiation therapy for esophageal cancer had computed tomography (CT) datasets acquired with full stomach (FS) and empty stomach (ES). We generated treatment plans for 3DCRT, IMRT, or IMRT-SIB for each patient on the ES-CT and on the FS-CT datasets. The 3DCRT and IMRT plans were planned to 50.4 Gy to the clinical target volume (CTV), and the same for IMRT-SIB plus 63.0 Gy to the gross tumor volume (GTV). Target coverage was evaluated using dose-volume histogram data for patient treatments simulated with ES-CT sets, assuming treatment on an FS for the entire course, and vice versa. FS volumes were a mean of 3.3 (range, 1.7-7.5) times greater than ES volumes. The volume of the GTV receiving >or=50.4 Gy (V(50.4Gy)) was 100% in all situations. The planning GTV V(63Gy) became suboptimal when gastric filling varied, regardless of whether simulation was done on the ES-CT or the FS-CT set. Stomach filling has a negligible impact on prescribed dose delivered to the GEJ GTV, using either 3DCRT or IMRT planning. Thus, local relapses are not likely to be related to variations in gastric filling. Dose escalation for GEJ tumors with IMRT-SIB may require gastric filling monitoring.
Bone Mineral Density across a Range of Physical Activity Volumes: NHANES 2007–2010
Whitfield, Geoffrey P.; Kohrt, Wendy M.; Pettee Gabriel, Kelley K.; Rahbar, Mohammad H.; Kohl, Harold W.
2014-01-01
Introduction The association between aerobic physical activity volume and bone mineral density (BMD) is not completely understood. The purpose of this study was to clarify the association between BMD and aerobic activity across a broad range of activity volumes, in particular volumes between those recommended in the 2008 Physical Activity Guidelines for Americans and those of trained endurance athletes. Methods Data from the 2007–2010 National Health and Nutrition Examination Survey were used to quantify the association between reported physical activity and BMD at the lumbar spine and proximal femur across the entire range of activity volumes reported by US adults. Participants were categorized into multiples of the minimum guideline-recommended volume based on reported moderate and vigorous intensity leisure activity. Lumbar and proximal femur BMD was assessed with dual-energy x-ray absorptiometry. Results Among women, multivariable-adjusted linear regression analyses revealed no significant differences in lumbar BMD across activity categories, while proximal femur BMD was significantly higher among those who exceeded guidelines by 2–4 times than those who reported no activity. Among men, multivariable-adjusted BMD at both sites neared its highest values among those who exceeded guidelines by at least 4 times and was not progressively higher with additional activity. Logistic regression estimating the odds of low BMD generally echoed the linear regression results. Conclusion The association between physical activity volume and BMD is complex. Among women, exceeding guidelines by 2–4 times may be important for maximizing BMD at the proximal femur, while among men, exceeding guidelines by 4+ times may be beneficial for lumbar and proximal femur BMD. PMID:24870584
4D planning over the full course of fractionation: assessment of the benefit of tumor trailing
NASA Astrophysics Data System (ADS)
McQuaid, D.; Bortfeld, T.
2011-11-01
Tumor trailing techniques have been proposed as a method of reducing the problem of intrafraction motion in radiotherapy. However the dosimetric assessment of trailing strategies is complicated by the requirement to study dose deposition over a full fraction delivery. Common 4D planning strategies allowing assessment of dosimetric motion effects study a single cycle acquired with 4DCT. In this paper, a methodology to assess dose deposited over an entire treatment course is advanced and used to assess the potential benefit of tumor trailing strategies for lung cancer patients. Two digital phantoms mimicking patient anatomy were each programmed to follow the tumor respiratory trajectory observed from 33 lung cancer patients. The two phantoms were designed to represent the cases of a small (volume = 13.6 cm3) and large (volume = 181.7 cm3) lung lesion. Motion margins required to obtain CTV coverage by 95% of the prescription dose to 90% of the available cases were computed for a standard treatment strategy and a trailing treatment strategy. The trailing strategy facilitated a margin reduction of over 30% relative to the conventional delivery. When the dose was computed across the entire delivery for the 33 cases, the trailing strategy was found to significantly reduce the underdosage to the outlier cases and the reduced trailing margin facilitated a 15% (small lesion) and 4% (large lesion) reduction for the mean lung dose and 7% (small lesion) and 10% (large lesion) for the mean esophagus dose. Finally, for comparison an ideal continuous tracking strategy was assessed and found to further reduce the mean lung and esophagus dose. However, this improvement comes at the price of increased delivery complexity and increased reliance on tumor localization accuracy.
Modelling compressible dense and dilute two-phase flows
NASA Astrophysics Data System (ADS)
Saurel, Richard; Chinnayya, Ashwin; Carmouze, Quentin
2017-06-01
Many two-phase flow situations, from engineering science to astrophysics, deal with transition from dense (high concentration of the condensed phase) to dilute concentration (low concentration of the same phase), covering the entire range of volume fractions. Some models are now well accepted at the two limits, but none are able to cover accurately the entire range, in particular regarding waves propagation. In the present work, an alternative to the Baer and Nunziato (BN) model [Baer, M. R. and Nunziato, J. W., "A two-phase mixture theory for the deflagration-to-detonation transition (DDT) in reactive granular materials," Int. J. Multiphase Flow 12(6), 861 (1986)], initially designed for dense flows, is built. The corresponding model is hyperbolic and thermodynamically consistent. Contrarily to the BN model that involves 6 wave speeds, the new formulation involves 4 waves only, in agreement with the Marble model [Marble, F. E., "Dynamics of a gas containing small solid particles," Combustion and Propulsion (5th AGARD Colloquium) (Pergamon Press, 1963), Vol. 175] based on pressureless Euler equations for the dispersed phase, a well-accepted model for low particle volume concentrations. In the new model, the presence of pressure in the momentum equation of the particles and consideration of volume fractions in the two phases render the model valid for large particle concentrations. A symmetric version of the new model is derived as well for liquids containing gas bubbles. This model version involves 4 characteristic wave speeds as well, but with different velocities. Last, the two sub-models with 4 waves are combined in a unique formulation, valid for the full range of volume fractions. It involves the same 6 wave speeds as the BN model, but at a given point of space, 4 waves only emerge, depending on the local volume fractions. The non-linear pressure waves propagate only in the phase with dominant volume fraction. The new model is tested numerically on various test problems ranging from separated phases in a shock tube to shock-particle cloud interaction. Its predictions are compared to BN and Marble models as well as against experimental data showing clear improvements.
Haegelen, Claire; Perucca, Piero; Châtillon, Claude-Edouard; Andrade-Valença, Luciana; Zelmann, Rina; Jacobs, Julia; Collins, D. Louis; Dubeau, François; Olivier, André; Gotman, Jean
2013-01-01
Summary Purpose Removal of areas generating high-frequency oscillations (HFOs) recorded from the intracerebral electroencephalography (iEEG) of patients with medically intractable epilepsy has been found to be correlated with improved surgical outcome. However, whether differences exist according to the type of epilepsy is largely unknown. We performed a comparative assessment of the impact of removing HFO-generating tissue on surgical outcome between temporal lobe epilepsy (TLE) and extratemporal lobe epilepsy (ETLE). We also assessed the relationship between the extent of surgical resection and surgical outcome. Methods We studied 30 patients with drug-resistant focal epilepsy, 21 with TLE and 9 with ETLE. Two thirds of the patients were included in a previous report and for these, clinical and imaging data were updated and follow-up was extended. All patients underwent iEEG investigations (500 Hz high-pass filter and 2,000 Hz sampling rate), surgical resection, and postoperative magnetic resonance imaging (MRI). HFOs (ripples, 80–250 Hz; fast ripples, >250 Hz) were identified visually on a 5–10 min interictal iEEG sample. HFO rates inside versus outside the seizure-onset zone (SOZ), in resected versus nonresected tissue, and their association with surgical outcome (ILAE classification) were assessed in the entire cohort, and in the TLE and ETLE subgroups. We also tested the correlation of resected brain hippocampal and amygdala volumes (as measured on postoperative MRIs) with surgical outcome. Key Findings HFO rates were significantly higher inside the SOZ than outside in the entire cohort and TLE subgroup, but not in the ETLE subgroup. In all groups, HFO rates did not differ significantly between resected and nonresected tissue. Surgical outcome was better when higher HFO rates were included in the surgical resection in the entire cohort and TLE subgroup, but not in the ETLE subgroup. Resected brain hippocampal and amygdala volumes were not correlated with surgical outcome. Significance In TLE, removal of HFO-generating areas may lead to improved surgical outcome. Less consistent findings emerge from ETLE, but these may be related to sample size limitations of this study. Size of resection, a factor that was ignored and that could have affected results of earlier studies did not influence results. PMID:23294353
Influence of Bisphenol A on Thyroid Volume and Structure Independent of Iodine in School Children
Wang, Na; Zhou, Ying; Fu, Chaowei; Wang, Hexing; Huang, Peixin; Wang, Bin; Su, Meifang; Jiang, Feng; Fang, Hong; Zhao, Qi; Chen, Yue; Jiang, Qingwu
2015-01-01
Background Although several studies have evaluated the relationship between bisphenol A (BPA) and thyroid functions, their results are not entirely consistent. Little is known about BPA in relation to thyroid volume and structure. Methods We examined the association of BPA with thyroid volume and thyroid nodules using data from 718 Chinese children living in the East Coast of China in 2012. First morning urine samples were collected for the determination of urinary BPA, creatinine, and urinary iodine concentrations (UIC). Thyroid volume (TV) and nodules were assessed by thyroid ultrasonography. Results The median of TV was 3.14ml. 459(63.9%) children took iodized salt at home and the median of UIC was 159μg/l. BPA was detected in 99.9% of the urine samples and the medians for boys and girls were 2.64 and 2.35μg/g creatinine, respectively. Of all participants 14.0% had thyroid nodules. Urinary BPA concentration was inversely associated with thyroid volume (β = -0.033, 95% CI: -0.053, -0.013) and the risk for multiple nodules (OR = 0.78; 95% CI: 0.63, 0.97). The associations above were similar for children who consumed iodized salt and those consumed non-iodized salt. Conclusions The data suggest that BPA may be one of the influencing factors for TV and thyroid nodules and its effects are independent of iodine nutrition status in children. PMID:26496713
NASA Technical Reports Server (NTRS)
Shiota, T.; McCarthy, P. M.; White, R. D.; Qin, J. X.; Greenberg, N. L.; Flamm, S. D.; Wong, J.; Thomas, J. D.
1999-01-01
The geometry of the left ventricle in patients with cardiomyopathy is often sub-optimal for 2-dimensional ultrasound when assessing left ventricular (LV) function and localized abnormalities such as a ventricular aneurysm. The aim of this study was to report the initial experience of real-time 3-D echocardiography for evaluating patients with cardiomyopathy. A total of 34 patients were evaluated with the real-time 3D method in the operating room (n = 15) and in the echocardiographic laboratory (n = 19). Thirteen of 28 patients with cardiomyopathy and 6 other subjects with normal LV function were evaluated by both real-time 3-D echocardiography and magnetic resonance imaging (MRI) for obtaining LV volumes and ejection fractions for comparison. There were close relations and agreements for LV volumes (r = 0.98, p <0.0001, mean difference = -15 +/- 81 ml) and ejection fractions (r = 0.97, p <0.0001, mean difference = 0.001 +/- 0.04) between the real-time 3D method and MRI when 3 cardiomyopathy cases with marked LV dilatation (LV end-diastolic volume >450 ml by MRI) were excluded. In these 3 patients, 3D echocardiography significantly underestimated the LV volumes due to difficulties with imaging the entire LV in a 60 degrees x 60 degrees pyramidal volume. The new real-time 3D echocardiography is feasible in patients with cardiomyopathy and may provide a faster and lower cost alternative to MRI for evaluating cardiac function in patients.
Horstmann, Heinz; Körber, Christoph; Sätzler, Kurt; Aydin, Daniel; Kuner, Thomas
2012-01-01
High resolution, three-dimensional (3D) representations of cellular ultrastructure are essential for structure function studies in all areas of cell biology. While limited subcellular volumes have been routinely examined using serial section transmission electron microscopy (ssTEM), complete ultrastructural reconstructions of large volumes, entire cells or even tissue are difficult to achieve using ssTEM. Here, we introduce a novel approach combining serial sectioning of tissue with scanning electron microscopy (SEM) using a conductive silicon wafer as a support. Ribbons containing hundreds of 35 nm thick sections can be generated and imaged on the wafer at a lateral pixel resolution of 3.7 nm by recording the backscattered electrons with the in-lens detector of the SEM. The resulting electron micrographs are qualitatively comparable to those obtained by conventional TEM. S3EM images of the same region of interest in consecutive sections can be used for 3D reconstructions of large structures. We demonstrate the potential of this approach by reconstructing a 31.7 µm3 volume of a calyx of Held presynaptic terminal. The approach introduced here, Serial Section SEM (S3EM), for the first time provides the possibility to obtain 3D ultrastructure of large volumes with high resolution and to selectively and repetitively home in on structures of interest. S3EM accelerates process duration, is amenable to full automation and can be implemented with standard instrumentation. PMID:22523574
Horstmann, Heinz; Körber, Christoph; Sätzler, Kurt; Aydin, Daniel; Kuner, Thomas
2012-01-01
High resolution, three-dimensional (3D) representations of cellular ultrastructure are essential for structure function studies in all areas of cell biology. While limited subcellular volumes have been routinely examined using serial section transmission electron microscopy (ssTEM), complete ultrastructural reconstructions of large volumes, entire cells or even tissue are difficult to achieve using ssTEM. Here, we introduce a novel approach combining serial sectioning of tissue with scanning electron microscopy (SEM) using a conductive silicon wafer as a support. Ribbons containing hundreds of 35 nm thick sections can be generated and imaged on the wafer at a lateral pixel resolution of 3.7 nm by recording the backscattered electrons with the in-lens detector of the SEM. The resulting electron micrographs are qualitatively comparable to those obtained by conventional TEM. S(3)EM images of the same region of interest in consecutive sections can be used for 3D reconstructions of large structures. We demonstrate the potential of this approach by reconstructing a 31.7 µm(3) volume of a calyx of Held presynaptic terminal. The approach introduced here, Serial Section SEM (S(3)EM), for the first time provides the possibility to obtain 3D ultrastructure of large volumes with high resolution and to selectively and repetitively home in on structures of interest. S(3)EM accelerates process duration, is amenable to full automation and can be implemented with standard instrumentation.
Koehler, Peter J.; Stahnisch, Frank W.
2013-01-01
The emergence of neurology as a separate specialty from internal medicine and psychiatry took several decades, starting at the end of the nineteenth century. This can be adequately reconstructed by focusing on the establishment of specialized journals, societies, university chairs, the invention and application of specific instruments, medical practices, and certainly also the publication of pivotal textbooks in the field. Particularly around 1900, the German-speaking countries played an integral role in this process. In this article, one aspect is extensively explored, notably the publication (in the twentieth century) of three comprehensive and influential multivolume and multiauthor handbooks entirely devoted to neurology. All available volumes of Max Lewandowsky's Handbuch der Neurologie (1910–1914) and the Handbuch der Neurologie (1935–1937) of Oswald Bumke and Otfrid Foerster were analyzed. The handbooks were then compared with Pierre Vinken's and George Bruyn's Handbook of Clinical Neurology (1968–2002). Over the span of nearly a century these publications became ever more comprehensive and developed into a global, encompassing project as is reflected in the increasing number of foreign authors. Whereas the first two handbooks were published mainly in German, “Vinken & Bruyn” was eventually published entirely in English, indicating the general changes in the scientific language of neurology after World War II. Distinctions include the uniformity of the series, manner of editorial involvement, thematic comprehensiveness, inclusion of volume editors in “Vinken & Bruyn,” and the provision of index volumes. The increasing use of authorities in various neurological subspecialties is an important factor by which these handbooks contrast with many compact neurological textbooks that were available at the time. For historiographical purposes, the three neurological handbooks considered here were important sources for the general study of the history of medicine and science and the history of neurology in particular. Moreover, they served as important catalyzers of the emergence of neurology as a new clinical specialty during the first decades of the twentieth century. PMID:24083680
Collected software engineering papers, volume 12
NASA Technical Reports Server (NTRS)
1994-01-01
This document is a collection of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) from November 1993 through October 1994. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. This is the 12th such volume of technical papers produced by the SEL. Although these papers cover several topics related to software engineering, they do not encompass the entire scope of SEL activities and interests. Additional information about the SEL and its research efforts may be obtained from the sources listed in the bibliography at the end of this document.
Collected software engineering papers, volume 11
NASA Technical Reports Server (NTRS)
1993-01-01
This document is a collection of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) from November 1992 through November 1993. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. This is the 11th such volume of technical papers produced by the SEL. Although these papers cover several topics related to software engineering, they do not encompass the entire scope of SEL activities and interests. Additional information about the SEL and its research efforts may be obtained from the sources listed in the bibliography at the end of this document.
Taylor bubbles at high viscosity ratios: experiments and numerical simulations
NASA Astrophysics Data System (ADS)
Hewakandamby, Buddhika; Hasan, Abbas; Azzopardi, Barry; Xie, Zhihua; Pain, Chris; Matar, Omar
2015-11-01
The Taylor bubble is a single long bubble which nearly fills the entire cross section of a liquid-filled circular tube, often occurring in gas-liquid slug flows in many industrial applications, particularly oil and gas production. The objective of this study is to investigate the fluid dynamics of three-dimensional Taylor bubble rising in highly viscous silicone oil in a vertical pipe. An adaptive unstructured mesh modelling framework is adopted here which can modify and adapt anisotropic unstructured meshes to better represent the underlying physics of bubble rising and reduce computational effort without sacrificing accuracy. The numerical framework consists of a mixed control volume and finite element formulation, a `volume of fluid'-type method for the interface-capturing based on a compressive control volume advection method, and a force-balanced algorithm for the surface tension implementation. Experimental results for the Taylor bubble shape and rise velocity are presented, together with numerical results for the dynamics of the bubbles. A comparison of the simulation predictions with experimental data available in the literature is also presented to demonstrate the capabilities of our numerical method. EPSRC Programme Grant, MEMPHIS, EP/K0039761/1.
Frozen waterfall (or ice cascade) growth and decay: a thermodynamic approach
NASA Astrophysics Data System (ADS)
Gauthier, Francis; Montagnat, Maurine; Weiss, Jérôme; Allard, Michel; Hétu, Bernard
2013-04-01
The ice volume evolution of an ice cascade was studied using a thermodynamic model. The model was developed from meteorological data collected in the vicinity of the waterfall and validated from ice volume measurements estimated from terrestrial LiDAR images. The ice cascade forms over a 45 m high rockwall located in northern Gaspésie, Québec, Canada. Two stages of formation were identified. During the first stage, the growth is mainly controlled by air convection around the flowing and freefalling water. The ice cascade growth rate increases with the decreasing air temperature below 0°C and when the water flow reaches its lowest level. During the second stage, the ice cascade covers the entire rockwall surface, water flow is isolated from the outside environment and ice volume increases asymptotically. Heat is evacuated from the water flow through the ice cover by conduction. The growth is mainly controlled by the radiation energy balance but more specifically by the longwave radiation emitted at the ice surface during the night. In spring, melting of the ice cascade is clearly dependant on the sensible heat carried by the increasing water flow and the diffuse solar radiation received at the ice surface during the day.
The last interglaciation at Owens Lake, California; Core OL-92
Bischoff, James L.
1998-01-01
Owens Lake, located at the eastern base of the central Sierra Nevada (Fig. 1), was the terminus of the Owens River prior to the lake's complete desiccation shortly after 1913 due to river diversion by the City of Los Angeles. During earlier wetter cycles, the lake overflowed to fill a series of downstream basins including China Lake Basin, Searles Valley, Panamint Valley, and ultimately, Death Valley (Smith and Street-Perrott, 1983). In 1992 the U.S. Geological Survey drilled a 323-m-deep core (OL-92) into Owens Lake sediments near the depocenter of the basin to obtain a continuous record of silty-clay sediment spanning the last 800,000 yrs. A multi-parameter reconnaissance study of the entire core (ca 7000-yr resolution), was reported in a 13-chapter summary volume (Smith and Bischoff, 1997). A document containing the numerical and other detailed forms of raw data collected by that volume's authors was prepared earlier (Smith and Bischoff, 1993). The reconnaissance study provided an approximate time-depth model for the entire core, based on radiocarbon dates from the top 31m, the Bishop Ash (759,000 yrs) at 304 m, ten within-Brunhes paleomagnetic excursions, and a compaction-corrected mass-accumulation rate of 51.4 g/cm/l000yr (Bischoff et al., 1997a). Application of this model to observed sediment parameters indicates that Owens Lake was saline, alkaline, and biologically productive at times of decreased water-flow, and was generally hydrologically flushed and relatively unproductive during times of increased water-flow. Grain size, abundance of CaCO3, organic carbon, clay mineralogy, cation-exchange capacity of the clay fraction, fossil pollen, fish, ostracodes, and diatoms (see summary by Smith et al., 1997) all show cyclic variation down the core. CaCO3 abundance, in particular, strongly reflects an approximately 100 ka dominant cycle, characteristic of global ice-volume indicated by the MIS δ18O record. Four of the last five marine isotope terminations are clearly shown in the OL-92 record.
van Noort, Kim; Schuurmann, Richte Cl; Wermelink, Bryan; Slump, Cornelis H; Kuijpers, Karel C; de Vries, Jean-Paul Pm
2017-10-01
Objectives The results after aneurysm repair with an endovascular aneurysm sealing (EVAS) system are dependent on the stability of the aneurysm sac and particularly the intraluminal abdominal aortic thrombus (ILT). The postprocedural ILT volume is decreased compared with preprocedural ILT volume in aortic aneurysm patients treated with EVAS. We hypothesize that ILT is not stable in all patients and pressurization of the ILT may result in displacement of fluids from the ILT, no differently than serum is displaced from whole blood when it settles. To date, the mechanism and quantification of fluid displacement from ILT are unknown. Methods The study included 21 patients who underwent elective open abdominal aortic aneurysm repair. The ILT was harvested as a routine procedure during the operation. After excision of a histologic sample of the ILT specimen in four patients, ILT volume was measured and the ILT was compressed in a dedicated compression setup designed to apply uniform compression of 200 mmHg for 5 min. After compression, the volumes of the remaining thrombus and the displaced fluid were measured. Results The median (interquartile-range) of ILT volume before compression was 60 (66) mL, and a median of 5.7 (8.4) mL of fluid was displaced from the ILT after compression, resulting in a median thrombus volume decrease of 11% (10%). Fluid components can be up to 31% of the entire ILT volume. Histologic examination of four ILT specimens showed a reduction of the medial layer of the ILT after compression, which was the result of compression of fluid-containing canaliculi. Conclusions Applying pressure of 200 mmHg to abdominal aortic aneurysm ILT resulted in the displacement of fluid, with a large variation among patients. Fluid displacement may result in decrease of ILT volume during and after EVAS, which might have implications on pre-EVAS volume planning and on stability of the endobags during follow-up which may lead to migration, endoleak or both.
Anatomical study of the pelvis in patients with adolescent idiopathic scoliosis
Qiu, Xu-Sheng; Zhang, Jun-Jie; Yang, Shang-Wen; Lv, Feng; Wang, Zhi-Wei; Chiew, Jonathan; Ma, Wei-Wei; Qiu, Yong
2012-01-01
Standing posterior–anterior (PA) radiographs from our clinical practice show that the concave and convex ilia are not always symmetrical in patients with adolescent idiopathic scoliosis (AIS). Transverse pelvic rotation may explain this observation, or pelvic asymmetry may be responsible. The present study investigated pelvic symmetry by examining the volume and linear measurements of the two hipbones in patients with AIS. Forty-two female patients with AIS were recruited for the study. Standing PA radiographs (covering the thoracic and lumbar spinal regions and the entire pelvis), CT scans and 3D reconstructions of the pelvis were obtained for all subjects. The concave/convex ratio of the inferior ilium at the sacroiliac joint medially (SI) and the anterior superior iliac spine laterally (ASIS) were measured on PA radiographs. Hipbone volumes and several distortion and abduction parameters were measured by post-processing software. The concave/convex ratio of SI–ASIS on PA radiographs was 0.97, which was significantly < 1 (P < 0.001). The concave and convex hipbone volumes were comparable in patients with AIS. The hipbone volumes were 257.3 ± 43.5 cm3 and 256.9 ± 42.6 cm3 at the concave and convex sides, respectively (P > 0.05). Furthermore, all distortion and abduction parameters were comparable between the convex and concave sides. Therefore, the present study showed that there was no pelvic asymmetry in patients with AIS, although the concave/convex ratio of SI–ASIS on PA radiographs was significantly < 1. The clinical phenomenon of asymmetrical concave and convex ilia in patients with AIS in preoperative standing PA radiographs may be caused by transverse pelvic rotation, but it is not due to developmental asymmetry or distortion of the pelvis. PMID:22133294
Anatomical study of the pelvis in patients with adolescent idiopathic scoliosis.
Qiu, Xu-Sheng; Zhang, Jun-Jie; Yang, Shang-Wen; Lv, Feng; Wang, Zhi-Wei; Chiew, Jonathan; Ma, Wei-Wei; Qiu, Yong
2012-02-01
Standing posterior-anterior (PA) radiographs from our clinical practice show that the concave and convex ilia are not always symmetrical in patients with adolescent idiopathic scoliosis (AIS). Transverse pelvic rotation may explain this observation, or pelvic asymmetry may be responsible. The present study investigated pelvic symmetry by examining the volume and linear measurements of the two hipbones in patients with AIS. Forty-two female patients with AIS were recruited for the study. Standing PA radiographs (covering the thoracic and lumbar spinal regions and the entire pelvis), CT scans and 3D reconstructions of the pelvis were obtained for all subjects. The concave/convex ratio of the inferior ilium at the sacroiliac joint medially (SI) and the anterior superior iliac spine laterally (ASIS) were measured on PA radiographs. Hipbone volumes and several distortion and abduction parameters were measured by post-processing software. The concave/convex ratio of SI-ASIS on PA radiographs was 0.97, which was significantly < 1 (P < 0.001). The concave and convex hipbone volumes were comparable in patients with AIS. The hipbone volumes were 257.3 ± 43.5 cm(3) and 256.9 ± 42.6 cm(3) at the concave and convex sides, respectively (P > 0.05). Furthermore, all distortion and abduction parameters were comparable between the convex and concave sides. Therefore, the present study showed that there was no pelvic asymmetry in patients with AIS, although the concave/convex ratio of SI-ASIS on PA radiographs was significantly < 1. The clinical phenomenon of asymmetrical concave and convex ilia in patients with AIS in preoperative standing PA radiographs may be caused by transverse pelvic rotation, but it is not due to developmental asymmetry or distortion of the pelvis. © 2011 The Authors. Journal of Anatomy © 2011 Anatomical Society.
Shek, Yuen Lai; Chalikian, Tigran V
2013-01-29
We report the first application of volume and compressibility measurements to characterization of interactions between cosolvents (osmolytes) and globular proteins. Specifically, we measure the partial molar volumes and adiabatic compressibilities of cytochrome c, ribonuclease A, lysozyme, and ovalbumin in aqueous solutions of the stabilizing osmolyte glycine betaine (GB) at concentrations between 0 and 4 M. The fact that globular proteins do not undergo any conformational transitions in the presence of GB provides an opportunity to study the interactions of GB with proteins in their native states within the entire range of experimentally accessible GB concentrations. We analyze our resulting volumetric data within the framework of a statistical thermodynamic model in which each instance of GB interaction with a protein is viewed as a binding reaction that is accompanied by release of four water molecules. From this analysis, we calculate the association constants, k, as well as changes in volume, ΔV(0), and adiabatic compressibility, ΔK(S0), accompanying each GB-protein association event in an ideal solution. By comparing these parameters with similar characteristics determined for low-molecular weight analogues of proteins, we conclude that there are no significant cooperative effects involved in interactions of GB with any of the proteins studied in this work. We also evaluate the free energies of direct GB-protein interactions. The energetic properties of GB-protein association appear to scale with the size of the protein. For all proteins, the highly favorable change in free energy associated with direct protein-cosolvent interactions is nearly compensated by an unfavorable free energy of cavity formation (excluded volume effect), yielding a modestly unfavorable free energy for the transfer of a protein from water to a GB/water mixture.
Perez, David L; Matin, Nassim; Barsky, Arthur; Costumero-Ramos, Victor; Makaretz, Sara J; Young, Sigrid S; Sepulcre, Jorge; LaFrance, W Curt; Keshavan, Matcheri S; Dickerson, Bradford C
2017-06-01
Adverse early-life events are predisposing factors for functional neurological disorder (FND) and post-traumatic stress disorder (PTSD). Cingulo-insular regions are implicated in the biology of both conditions and are sites of stress-mediated neuroplasticity. We hypothesised that functional neurological symptoms and the magnitude of childhood abuse would be associated with overlapping anterior cingulate cortex (ACC) and insular volumetric reductions, and that FND and PTSD symptoms would map onto distinct cingulo-insular areas. This within-group voxel-based morphometry study probes volumetric associations with self-report measures of functional neurological symptoms, adverse life events and PTSD symptoms in 23 mixed-gender FND patients. Separate secondary analyses were also performed in the subset of 18 women with FND to account for gender-specific effects. Across the entire cohort, there were no statistically significant volumetric associations with self-report measures of functional neurological symptom severity or childhood abuse. In women with FND, however, parallel inverse associations were observed between left anterior insular volume and functional neurological symptoms as measured by the Patient Health Questionnaire-15 and the Screening for Somatoform Symptoms Conversion Disorder subscale. Similar inverse relationships were also appreciated between childhood abuse burden and left anterior insular volume. Across all subjects, PTSD symptom severity was inversely associated with dorsal ACC volume, and the magnitude of lifetime adverse events was inversely associated with left hippocampal volume. This study reveals distinct cingulo-insular alterations for FND and PTSD symptoms and may advance our understanding of FND. Potential biological convergence between stress-related neuroplasticity, functional neurological symptoms and reduced insular volume was identified. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
A method for quantitative mapping of thick oil spills using imaging spectroscopy
Clark, Roger N.; Swayze, Gregg A.; Leifer, Ira; Livo, K. Eric; Kokaly, Raymond F.; Hoefen, Todd; Lundeen, Sarah; Eastwood, Michael; Green, Robert O.; Pearson, Neil; Sarture, Charles; McCubbin, Ian; Roberts, Dar; Bradley, Eliza; Steele, Denis; Ryan, Thomas; Dominguez, Roseanne; ,
2010-01-01
In response to the Deepwater Horizon oil spill in the Gulf of Mexico, a method of near-infrared imaging spectroscopic analysis was developed to map the locations of thick oil floating on water. Specifically, this method can be used to derive, in each image pixel, the oil-to-water ratio in oil emulsions, the sub-pixel areal fraction, and its thicknesses and volume within the limits of light penetration into the oil (up to a few millimeters). The method uses the shape of near-infrared (NIR) absorption features and the variations in the spectral continuum due to organic compounds found in oil to identify different oil chemistries, including its weathering state and thickness. The method is insensitive to complicating conditions such as moderate aerosol scattering and reflectance level changes from other conditions, including moderate sun glint. Data for this analysis were collected by the NASA Airborne Visual Infrared Imaging Spectrometer (AVIRIS) instrument, which was flown over the oil spill on May 17, 2010. Because of the large extent of the spill, AVIRIS flight lines could cover only a portion of the spill on this relatively calm, nearly cloud-free day. Derived lower limits for oil volumes within the top few millimeters of the ocean surface directly probed with the near-infrared light detected in the AVIRIS scenes were 19,000 (conservative assumptions) to 34,000 (aggressive assumptions) barrels of oil. AVIRIS covered about 30 percent of the core spill area, which consisted of emulsion plumes and oil sheens. Areas of oil sheen but lacking oil emulsion plumes outside of the core spill were not evaluated for oil volume in this study. If the core spill areas not covered by flight lines contained similar amounts of oil and oil-water emulsions, then extrapolation to the entire core spill area defined by a MODIS (Terra) image collected on the same day indicates a minimum of 66,000 to 120,000 barrels of oil was floating on the surface. These estimates are preliminary and subject to revision pending further analysis. Based on laboratory measurements, near-infrared (NIR) photons penetrate only a few millimeters into oil-water emulsions. As such, the oil volumes derived with this method are lower limits. Further, the detection is only of thick surface oil and does not include sheens, underwater oil, or oil that had already washed onto beaches and wetlands, oil that had been burned or evaporated as of May 17. Because NIR light penetration within emulsions is limited, and having made field observations that oil emulsions sometimes exceeded 20 millimeters in thickness, we estimate that the volume of oil, including oil thicker than can be probed in the AVIRIS imagery, is possibly as high as 150,000 barrels in the AVIRIS scenes. When this value is projected to the entire spill, it gives a volume of about 500,000 barrels for thick oil remaining on the sea surface as of May 17. AVIRIS data cannot be used to confirm this higher volume, and additional field work including more in-situ measurements of oil thickness would be required to confirm this higher oil volume. Both the directly detected minimum range of oil volume, and the higher possible volume projection for oil thicker than can be probed with NIR spectroscopy imply a significantly higher total volume of oil relative to that implied by the early NOAA (National Oceanic and Atmospheric Administration) estimate of 5,000 barrels per day reported on their Web site.
Challenges in Accommodating Volume Change of Si Anodes for Li-Ion Batteries
Ko, Minseong; Chae, Sujong; Cho, Jaephil
2015-01-01
Si has been considered as a promising alternative anode for next-generation Li-ion batteries (LIBs) because of its high theoretical energy density, relatively low working potential, and abundance in nature. However, Si anodes exhibit rapid capacity decay and an increase in the internal resistance, which are caused by the large volume changes upon Li insertion and extraction. This unfortunately limits their practical applications. Therefore, managing the total volume change remains a critical challenge for effectively alleviating the mechanical fractures and instability of solid-electrolyte-interphase products. In this regard, we review the recent progress in volume-change-accommodating Si electrodes and investigate their ingenious structures with significant improvements in the battery performance, including size-controlled materials, patterned thin films, porous structures, shape-preserving shell designs, and graphene composites. These representative approaches potentially overcome the large morphologic changes in the volume of Si anodes by securing the strain relaxation and structural integrity in the entire electrode. Finally, we propose perspectives and future challenges to realize the practical application of Si anodes in LIB systems. PMID:27525208
Three-dimensional laser velocimeter simultaneity detector
NASA Technical Reports Server (NTRS)
Brown, James L. (Inventor)
1990-01-01
A three-dimensional laser Doppler velocimeter has laser optics for a first channel positioned to create a probe volume in space, and laser optics and for second and third channels, respectively, positioned to create entirely overlapping probe volumes in space. The probe volumes and overlap partially in space. The photodetector is positioned to receive light scattered by a particle present in the probe volume, while photodetectors and are positioned to receive light scattered by a particle present in the probe volume. The photodetector for the first channel is directly connected to provide a first channel analog signal to frequency measuring circuits. The first channel is therefore a primary channel for the system. Photodetectors and are respectively connected through a second channel analog signal attenuator to frequency measuring circuits and through a third channel analog signal attenuator to frequency measuring circuits. The second and third channels are secondary channels, with the second and third channels analog signal attenuators and controlled by the first channel measurement burst signal on line. The second and third channels analog signal attenuators and attenuate the second and third channels analog signals only when the measurement burst signal is false.
Monitoring landscape change for LANDFIRE using multi-temporal satellite imagery and ancillary data
James E. Vogelmann; Jay R. Kost; Brian Tolk; Stephen Howard; Karen Short; Xuexia Chen; Chengquan Huang; Kari Pabst; Matthew G. Rollins
2011-01-01
LANDFIRE is a large interagency project designed to provide nationwide spatial data for fire management applications. As part of the effort, many 2000 vintage Landsat Thematic Mapper and Enhanced Thematic Mapper plus data sets were used in conjunction with a large volume of field information to generate detailed vegetation type and structure data sets for the entire...
Probing the inner space of resorcinarene molecular capsules with nitroxide guests.
Mileo, Elisabetta; Yi, Song; Bhattacharya, Papri; Kaifer, Angel E
2009-01-01
In quarantine: Nitroxide spin probes are encapsulated by hexameric resorcinarene molecular capsules in dichloromethane solutions (see picture). A substantial reduction in the tumbling rates occurs upon encapsulation of two cationic probes and one neutral probe. As the molecular volume of the probe increases, the tumbling rate of the probe reflects the overall tumbling rate of the entire supramolecular assembly.
Army Communicator. Volume 36, Number 4, Winter 2011
2011-01-01
Association for Home Builders . Prior to becoming the command sergeant major of the Army Communications- Electronics Life Cycle Management...development of future senior civilian IT leaders. He headed the Army’s functional civilian personnel system for IT for his entire senior...pride in Functional Area 53 – Information Systems Management, I have to respectfully disagree with his characterization of Functional Area 57
Roaming Days: Warrior Stories. Blackfeet Heritage Program.
ERIC Educational Resources Information Center
Comes At Night, George
The history and culture of the Blackfeet people are reflected in the 10 tales that comprise this volume. Because George Comes At Night already has had considerable experience as a writer, little editing was needed for the book and the stories are almost entirely in the words of the 61-year old author. He states that he has written the stories as…
Naval War College Review. Volume 64, Number 2, Spring 2011
2011-01-01
to revolutionize the African maritime sector holistically, across its entire spectrum—improving safety and security, gover - nance, and industrial...strategy for a maritime economy that includes the enabling elements of gover - nance, infrastructure, trade, safety, and security and plainly tells global...transport in its core function); tourism ; energy; infrastructure (ports); cooperation on safety, security, and environmental protection; tariff harmonization
Sampling and mapping forest volume and biomass using airborne LIDARs
Erik Naesset; Terje Gobakken; Ross Nelson
2009-01-01
Since around 1995, extensive research efforts have been made in Scandinavia to develop airborne Light Detection and Ranging (LIDAR) as an operational tool for wall-to-wall mapping of forest stands for planning purposes. Scanning LIDAR has the ability to capture the entire three-dimensional structure of forest canopies and has therefore proved to be a very efficient...
ERIC Educational Resources Information Center
Basch, Charles E.; Gracy, Delaney; Johnson, Dennis; Fabian, Anupa
2015-01-01
Education is a critical pathway by which children can rise out of the cycle of poverty. Billions of dollars are invested annually in America's public schools and considerable improvement has been made in academic achievement and educational attainment. However, certain school-aged cohorts--entire communities of youth--have been left behind. An…
Tracking the Time-Dependent Role of the Hippocampus in Memory Recall Using DREADDs.
Varela, Carmen; Weiss, Sarah; Meyer, Retsina; Halassa, Michael; Biedenkapp, Joseph; Wilson, Matthew A; Goosens, Ki Ann; Bendor, Daniel
2016-01-01
The hippocampus is critical for the storage of new autobiographical experiences as memories. Following an initial encoding stage in the hippocampus, memories undergo a process of systems-level consolidation, which leads to greater stability through time and an increased reliance on neocortical areas for retrieval. The extent to which the retrieval of these consolidated memories still requires the hippocampus is unclear, as both spared and severely degraded remote memory recall have been reported following post-training hippocampal lesions. One difficulty in definitively addressing the role of the hippocampus in remote memory retrieval is the precision with which the entire volume of the hippocampal region can be inactivated. To address this issue, we used Designer Receptors Exclusively Activated by Designer Drugs (DREADDs), a chemical-genetic tool capable of highly specific neuronal manipulation over large volumes of brain tissue. We find that remote (>7 weeks after acquisition), but not recent (1-2 days after acquisition) contextual fear memories can be recalled after injection of the DREADD agonist (CNO) in animals expressing the inhibitory DREADD in the entire hippocampus. Our data demonstrate a time-dependent role of the hippocampus in memory retrieval, supporting the standard model of systems consolidation.
Tracking the Time-Dependent Role of the Hippocampus in Memory Recall Using DREADDs
Varela, Carmen; Weiss, Sarah; Meyer, Retsina; Halassa, Michael; Biedenkapp, Joseph; Wilson, Matthew A.; Goosens, Ki Ann
2016-01-01
The hippocampus is critical for the storage of new autobiographical experiences as memories. Following an initial encoding stage in the hippocampus, memories undergo a process of systems-level consolidation, which leads to greater stability through time and an increased reliance on neocortical areas for retrieval. The extent to which the retrieval of these consolidated memories still requires the hippocampus is unclear, as both spared and severely degraded remote memory recall have been reported following post-training hippocampal lesions. One difficulty in definitively addressing the role of the hippocampus in remote memory retrieval is the precision with which the entire volume of the hippocampal region can be inactivated. To address this issue, we used Designer Receptors Exclusively Activated by Designer Drugs (DREADDs), a chemical-genetic tool capable of highly specific neuronal manipulation over large volumes of brain tissue. We find that remote (>7 weeks after acquisition), but not recent (1–2 days after acquisition) contextual fear memories can be recalled after injection of the DREADD agonist (CNO) in animals expressing the inhibitory DREADD in the entire hippocampus. Our data demonstrate a time-dependent role of the hippocampus in memory retrieval, supporting the standard model of systems consolidation. PMID:27145133
Mechanisms of boron fiber strengthening by thermal treatment
NASA Technical Reports Server (NTRS)
Dicarlo, J. A.
1979-01-01
The fracture strain for boron on tungsten fibers can be improved by heat treatment under vacuum or argon environments. The mechanical basis for this improvement is thermally-induced axial contraction of the entire fiber, whereby strength-controlling core flaws are compressed and fiber fracture strain increased by the value of the contraction strain. By highly sensitive measurements of fiber density and volume, the physical mechanisms responsible for contraction under both environments was identified as boron atom diffusion out of the fiber sheath. The fiber contracts because the average volume of the resulting microvoid was determined to be only 0.26 + or - 0.09 the average atomic volume of the removed atom. The basic and practical implications of these results are discussed with particular emphasis on the theory, use, and limitations of heat-induced contraction as a simple cost-effective secondary processing method.
Method and apparatus for reflection mode imaging
NASA Technical Reports Server (NTRS)
Heyser, Richard C. (Inventor); Rooney, James A. (Inventor)
1989-01-01
A volume is scanned with a raster scan about a center of rotation using a transmitter/receiver at a selected range while gating a range window on the receiver with a selected range differential. The received signals are then demodulated to obtain signals representative of a property within the volume being scanned such as the density of a tumor. The range is varied until the entire volume has been scanned at all ranges to be displayed. An imaging display is synchronously scanned together with the raster scan to display variations of the property on the display. A second transmitter/receiver with associated equipment may be offset from the first and variations displayed from each of the transmitter/receivers on its separate display. The displays may then be combined stereoscopically to provide a three-dimensional image representative of variations of the property.
Collected Software Engineering Papers, Volume 10
NASA Technical Reports Server (NTRS)
1992-01-01
This document is a collection of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) from Oct. 1991 - Nov. 1992. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. Although these papers cover several topics related to software engineering, they do not encompass the entire scope of SEL activities and interests. Additional information about the SEL and its research efforts may be obtained from the sources listed in the bibliography at the end of this document. For the convenience of this presentation, the 11 papers contained here are grouped into 5 major sections: (1) the Software Engineering Laboratory; (2) software tools studies; (3) software models studies; (4) software measurement studies; and (5) Ada technology studies.
Oliver, J.
1991-01-01
When I was a graduate student around 1950 I used to read the entire Bulletin of the Seismological Society of America. it was a pwoerful and inspiring educational experience, with an effect quite different from that of the more usual process of looking up a few articles in the chain of references in a subject of current interest. Reading the entire journal reveals how ideas, techniques, and seismologists appear and evolve. It is likely the best substitute for a firsthand personal experience with the early development of the field. And in spite of, or perhaps because of, the missteps, the wasted effort, and the lack of sophistication that those first volumes reveal, the reader can sense the opportunity and be inspired by the vibrancy of the young subject.
Determination of Urea Permeability in Red Cells by Minimum Method
Sha'afi, R. I.; Rich, G. T.; Mikulecky, D. C.; Solomon, A. K.
1970-01-01
A new method has been developed for measuring the permeability coefficient, ω, of small nonelectrolytes. The method depends upon a mathematical analysis of the time course of cell volume changes in the neighborhood of the minimum volume following addition of a permeating solute to an isosmolal buffer. Coefficients determined by the minimum volume method agree with those obtained using radioactive tracers. ω for urea in human red cells was found to decrease as the volume flow, Jv, into the cell increased. Such behavior is entirely unexpected for a single uniform rate-limiting barrier on the basis of the linear phenomenological equations derived from irreversible thermodynamics. However, the present findings are consonant with a complex membrane system consisting of a tight barrier on the outer face of the human red cell membrane and a somewhat less restrictive barrier behind it closer to the inner membrane face. A theoretical analysis of such a series model has been made which makes predictions consistent with the experimental findings. PMID:5435779
Sexual differentiation of the adolescent rat brain: A longitudinal voxel-based morphometry study.
Sumiyoshi, Akira; Nonaka, Hiroi; Kawashima, Ryuta
2017-03-06
The sexual differentiation of the rat brain during the adolescent period has been well documented in post-mortem histological studies. However, to further understand the morphological changes occurring in the entire brain, a noninvasive neuroimaging method allowing an unbiased, comprehensive, and longitudinal investigation of brain morphology should be used. In this study, we investigated the sexual differentiation of the rat brain during the adolescent period using longitudinal voxel-based morphometry (VBM) analysis. Male and female Wistar rats (n=12 of each) were scanned in a 7.0-T MRI scanner at five time points from 6 to 10 weeks of age. The T2-weighted MRI images were segmented using the rat brain tissue priors that have been published by our laboratory. At the global level, the results of the VBM analysis showed greater increases in total gray matter volume in the males during the adolescent period, although we did not find significant differences in total white matter volume. At the voxel level, we found significant increases in the regional gray matter volume of the occipital cortex, amygdala, hippocampal formation, and cerebellum. At the regional level, only the occipital cortex in the females exhibited decreases during the adolescent period. These results were, at least in part, consistent with those of previous longitudinal VBM studies in humans, thus providing translational evidence of the sexual differentiation of the developing brain between rodents and humans. Copyright © 2017 Elsevier B.V. All rights reserved.
Effect of dehydration on erythropoiesis in mice - Relevance to the 'anemia' of space flight
NASA Technical Reports Server (NTRS)
Dunn, C. D. R.
1978-01-01
Mice deprived of water for 24 h showed an increase in hematocrit and loss of body weight comparable to that seen in men during space flight. The increase in hematocrit was entirely due to a decrease in plasma volume and was associated with suppression of erythropoiesis, but with no significant change in the serum titer of a presumptive humoral regulator of erythropoiesis, Erythroid Stimulating Activity (ESA). Mice deprived of water for 24 h may be a useful model for the study of the early hematological effects of space flight. The suppression of erythropoiesis due to a relative erythrocytosis appears to be independent of ESA.
Invariance in the recurrence of large returns and the validation of models of price dynamics
NASA Astrophysics Data System (ADS)
Chang, Lo-Bin; Geman, Stuart; Hsieh, Fushing; Hwang, Chii-Ruey
2013-08-01
Starting from a robust, nonparametric definition of large returns (“excursions”), we study the statistics of their occurrences, focusing on the recurrence process. The empirical waiting-time distribution between excursions is remarkably invariant to year, stock, and scale (return interval). This invariance is related to self-similarity of the marginal distributions of returns, but the excursion waiting-time distribution is a function of the entire return process and not just its univariate probabilities. Generalized autoregressive conditional heteroskedasticity (GARCH) models, market-time transformations based on volume or trades, and generalized (Lévy) random-walk models all fail to fit the statistical structure of excursions.
High-Intensity Intermittent Exercise and Autonomic Modulation: Effects of Different Volume Sessions.
Castrillón, Carlos Iván Mesa; Miranda, Rodolfo Augusto Travagin; Cabral-Santos, Carolina; Vanzella, Lais Manata; Rodrigues, Bruno; Vanderlei, Luiz Carlos Marques; Lira, Fábio Santos; Campos, Eduardo Zapaterra
2017-06-01
The aim of this study was to compare heart rate variability (HRV) recovery after 2 sessions of high-intensity intermittent exercise at different volumes (1.25 km [HIIE 1.25 ] and 2.5 km [HIIE 2.5 ]). 13 participants determined their maximal aerobic speed (MAS) and completed 2 HIIE (1:1 at 100% MAS) trials. The heart rate was recorded before and after each session. HRV indicators were calculated according to time (RMSSD and SDNN) and frequency (LF, HF and LF/HF ratio) domains. SDNN and RMSSD presented effect of test (F=20.97; p<0.01 and F=21.00; p<0.01, respectively) and moment (F=6.76; p<0.01 and F=12.30; p<0.01, respectively), without interaction. Even though we did not find an interaction effect for any HRV variables, the HIIE 2.5 presented a delay of only 5 min in HRV recovery, when compared to HIIE 1.25 . However, the effects of the test (SDNN, RMSSD, LF-log, and HF-log) indicate higher autonomic stress during the entire recovery period. These findings may indicate that exercise volume interferes with HRV recovery. If so, physically active subjects may choose a lower volume exercise (i. e., HIIE 1.25 ) in order to promote similar physical fitness adaptations with lower loading on autonomic modulation. © Georg Thieme Verlag KG Stuttgart · New York.
Longitudinal Regional Brain Development and Clinical Risk Factors in Extremely Preterm Infants.
Kersbergen, Karina J; Makropoulos, Antonios; Aljabar, Paul; Groenendaal, Floris; de Vries, Linda S; Counsell, Serena J; Benders, Manon J N L
2016-11-01
To investigate third-trimester extrauterine brain growth and correlate this with clinical risk factors in the neonatal period, using serially acquired brain tissue volumes in a large, unselected cohort of extremely preterm born infants. Preterm infants (gestational age <28 weeks) underwent brain magnetic resonance imaging (MRI) at around 30 weeks postmenstrual age and again around term equivalent age. MRIs were segmented in 50 different regions covering the entire brain. Multivariable regression analysis was used to determine the influence of clinical variables on volumes at both scans, as well as on volumetric growth. MRIs at term equivalent age were available for 210 infants and serial data were available for 131 infants. Growth over these 10 weeks was greatest for the cerebellum, with an increase of 258%. Sex, birth weight z-score, and prolonged mechanical ventilation showed global effects on brain volumes on both scans. The effect of brain injury on ventricular size was already visible at 30 weeks, whereas growth data and volumes at term-equivalent age revealed the effect of brain injury on the cerebellum. This study provides data about third-trimester extrauterine volumetric brain growth in preterm infants. Both global and local effects of several common clinical risk factors were found to influence serial volumetric measurements, highlighting the vulnerability of the human brain, especially in the presence of brain injury, during this period. Copyright © 2016 Elsevier Inc. All rights reserved.
Automated 3D Ultrasound Image Segmentation to Aid Breast Cancer Image Interpretation
Gu, Peng; Lee, Won-Mean; Roubidoux, Marilyn A.; Yuan, Jie; Wang, Xueding; Carson, Paul L.
2015-01-01
Segmentation of an ultrasound image into functional tissues is of great importance to clinical diagnosis of breast cancer. However, many studies are found to segment only the mass of interest and not all major tissues. Differences and inconsistencies in ultrasound interpretation call for an automated segmentation method to make results operator-independent. Furthermore, manual segmentation of entire three-dimensional (3D) ultrasound volumes is time-consuming, resource-intensive, and clinically impractical. Here, we propose an automated algorithm to segment 3D ultrasound volumes into three major tissue types: cyst/mass, fatty tissue, and fibro-glandular tissue. To test its efficacy and consistency, the proposed automated method was employed on a database of 21 cases of whole breast ultrasound. Experimental results show that our proposed method not only distinguishes fat and non-fat tissues correctly, but performs well in classifying cyst/mass. Comparison of density assessment between the automated method and manual segmentation demonstrates good consistency with an accuracy of 85.7%. Quantitative comparison of corresponding tissue volumes, which uses overlap ratio, gives an average similarity of 74.54%, consistent with values seen in MRI brain segmentations. Thus, our proposed method exhibits great potential as an automated approach to segment 3D whole breast ultrasound volumes into functionally distinct tissues that may help to correct ultrasound speed of sound aberrations and assist in density based prognosis of breast cancer. PMID:26547117
Automated 3D ultrasound image segmentation for assistant diagnosis of breast cancer
NASA Astrophysics Data System (ADS)
Wang, Yuxin; Gu, Peng; Lee, Won-Mean; Roubidoux, Marilyn A.; Du, Sidan; Yuan, Jie; Wang, Xueding; Carson, Paul L.
2016-04-01
Segmentation of an ultrasound image into functional tissues is of great importance to clinical diagnosis of breast cancer. However, many studies are found to segment only the mass of interest and not all major tissues. Differences and inconsistencies in ultrasound interpretation call for an automated segmentation method to make results operator-independent. Furthermore, manual segmentation of entire three-dimensional (3D) ultrasound volumes is time-consuming, resource-intensive, and clinically impractical. Here, we propose an automated algorithm to segment 3D ultrasound volumes into three major tissue types: cyst/mass, fatty tissue, and fibro-glandular tissue. To test its efficacy and consistency, the proposed automated method was employed on a database of 21 cases of whole breast ultrasound. Experimental results show that our proposed method not only distinguishes fat and non-fat tissues correctly, but performs well in classifying cyst/mass. Comparison of density assessment between the automated method and manual segmentation demonstrates good consistency with an accuracy of 85.7%. Quantitative comparison of corresponding tissue volumes, which uses overlap ratio, gives an average similarity of 74.54%, consistent with values seen in MRI brain segmentations. Thus, our proposed method exhibits great potential as an automated approach to segment 3D whole breast ultrasound volumes into functionally distinct tissues that may help to correct ultrasound speed of sound aberrations and assist in density based prognosis of breast cancer.
Ventilatory responses to exercise training in obese adolescents.
Mendelson, Monique; Michallet, Anne-Sophie; Estève, François; Perrin, Claudine; Levy, Patrick; Wuyam, Bernard; Flore, Patrice
2012-10-15
The aim of this study was to examine ventilatory responses to training in obese adolescents. We assessed body composition, pulmonary function and ventilatory responses (among which expiratory flow limitation and operational lung volumes) during progressive cycling exercise in 16 obese adolescents (OB) before and after 12 weeks of exercise training and in 16 normal-weight volunteers. As expected, obese adolescents' resting expiratory reserve volume was lower and inversely correlated with thoraco-abdominal fat mass (r = -0.74, p<0.0001). OB presented lower end expiratory (EELV) and end inspiratory lung volumes (EILV) at rest and during submaximal exercise, and modest expiratory flow limitation. After training, OB increased maximal aerobic performance (+19%) and maximal inspiratory pressure (93.7±31.4 vs. 81.9±28.2 cm H2O, +14%) despite lack of decrease in trunk fat and body weight. Furthermore, EELV and EILV were greater during submaximal exercise (+11% and +9% in EELV and EILV, respectively), expiratory flow limitation delayed but was not accompanied by increased V(T). However, submaximal exertional symptoms (dyspnea and leg discomfort) were significantly decreased (-71.3% and -70.7%, respectively). Our results suggest that exercise training can improve pulmonary function at rest (static inspiratory muscle strength) and exercise (greater operating lung volumes and delayed expiratory flow limitation) but these modifications did not entirely account for improved dyspnea and exercise performance in obese adolescents. Copyright © 2012 Elsevier B.V. All rights reserved.
Clinical laboratory: bigger is not always better.
Plebani, Mario
2018-06-27
Laboratory services around the world are undergoing substantial consolidation and changes through mechanisms ranging from mergers, acquisitions and outsourcing, primarily based on expectations to improve efficiency, increasing volumes and reducing the cost per test. However, the relationship between volume and costs is not linear and numerous variables influence the end cost per test. In particular, the relationship between volumes and costs does not span the entire platter of clinical laboratories: high costs are associated with low volumes up to a threshold of 1 million test per year. Over this threshold, there is no linear association between volumes and costs, as laboratory organization rather than test volume more significantly affects the final costs. Currently, data on laboratory errors and associated diagnostic errors and risk for patient harm emphasize the need for a paradigmatic shift: from a focus on volumes and efficiency to a patient-centered vision restoring the nature of laboratory services as an integral part of the diagnostic and therapy process. Process and outcome quality indicators are effective tools to measure and improve laboratory services, by stimulating a competition based on intra- and extra-analytical performance specifications, intermediate outcomes and customer satisfaction. Rather than competing with economic value, clinical laboratories should adopt a strategy based on a set of harmonized quality indicators and performance specifications, active laboratory stewardship, and improved patient safety.
Viani, Gustavo Arruda; Godoi da Silva, Lucas Bernardes; Viana, Bruno Silveira; Rossi, Bruno Tiago; Suguikawa, Elton; Zuliani, Gisele
2016-01-01
The intention of this study is to compare whole brain radiotherapy and stereotactic radiosurgery (WBRT + SRS) with WBRT in patients with 1-4 brain metastases to find a subgroup of patients that have a great benefit with aggressive treatment. Between December 2002 and December 2013, 60 patients with 1-4 brain metastases were treated by WBRT + SRS. In this period, 60 patients treated with WBRT were matched with patients treated with WBRT + SRS. The median survival for the entire cohort was 8.3 months. In the univariate analysis, WBRT + SRS (0.031), the presence of extracranial disease (P = 0.02), Karnofsky performance score <70 (P = 0.0001), and age >65 (P = 0.001) years were significant factors for survival. In the entire cohort, the median survival for recursive partitioning analysis (RPA) classes I, II, and III was 11, 7, and 3 months, respectively (P = 0.0001). In a stratified analysis, only RPA class I achieved statistical significance for 1-year survival between the groups (WBRT + SRS = 51% and WBRT = 23%, P = 0.03). Cox regression analysis revealed WBRT + SRS, age >65 years, and extracranial disease as independent prognostic factors. In the univariate analysis, lesion volume ≤5 cm 3 (P = 0.002) and WBRT + SRS (P = 0.003) were the significant factors associated with better brain control. WBRT plus SRS was an independent prognostic factor for survival. However, the combined treatment appears to be justified only in patients with RPA I and lesion volume ≤5 cm 3, independently of the number of lesions.
Ionic requirements of proximal tubular sodium transport. I. Bicarbonate and chloride.
Green, R; Giebisch, G
1975-11-01
Simultaneous perfusion of peritubular capillaries and proximal convoluted tubules was used to study the effect of varying transepithelial ionic gradients on ionic fluxes. Results show that net sodium influx and volume flux was one-third of normal when bicarbonate was absent, no chloride gradient existed, and glucose and amino acids were absent. Addition of bicarbonate to the luminal fluid did not restore the flux to normal, but peritubular bicarbonate did restore it. A chloride gradient imposed when no bicarbonate was present could only increase the fluxes slightly, but his flux was significant even after cyanide had poisoned transport. Reversing the chloride concentration gradient decreased the net sodium and volume fluxes whether bicarbonate was present or not. Glucose had no effect on fluxes, but substitution of Na by choline abolished them entirely. It is concluded that sodium is actively transported, that a chloride concentration gradient from lumen to plasma could account for up to 20% of net transport, and that peritubular bicarbonate is necessary for normal rates of sodium and fluid absorption.
A study for the installation of the TEXT heavy-ion beam probe on DIII-D
NASA Astrophysics Data System (ADS)
Edmonds, P. H.; Solano, E. R.; Bravenec, R. V.; Wootton, A. J.; Schoch, P. M.; Crowley, T. P.; Hickok, R. L.; West, W. P.; Leuer, J.; Anderson, P.
1997-01-01
An assessment of the feasibility of installing the TEXT 2 MeV heavy-ion beam probe on the DIII-D tokamak has been completed. Detailed drawings of the machine cross section were imported into the CAD application AutoCAD. A set of programs written in AutoLisp were used to generate trajectories. Displays of the accessible cross section of the plasma, scan lines for the entire range of primary beam energy and injection angle ranges, and sample-volume dimensions can be rapidly generated. Because of the large deflection between the primary input beam and the emergent secondary beam, either the analyzer needs to be tracked over a ±20° angle or secondary poloidal deflector plates need to be installed at the exit port. Toroidal deflector plates will be installed at both the injection and exit ports to compensate for toroidal displacements and deflections. The sample volumes generated by this procedure are within a few centimeters of the locations derived from a full three-dimensional calculation.
The plug-based nanovolume Microcapillary Protein Crystallization System (MPCS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerdts, Cory J.; Elliott, Mark; Lovell, Scott
2012-02-08
The Microcapillary Protein Crystallization System (MPCS) embodies a new semi-automated plug-based crystallization technology which enables nanolitre-volume screening of crystallization conditions in a plasticware format that allows crystals to be easily removed for traditional cryoprotection and X-ray diffraction data collection. Protein crystals grown in these plastic devices can be directly subjected to in situ X-ray diffraction studies. The MPCS integrates the formulation of crystallization cocktails with the preparation of the crystallization experiments. Within microfluidic Teflon tubing or the microfluidic circuitry of a plastic CrystalCard, {approx}10-20 nl volume droplets are generated, each representing a microbatch-style crystallization experiment with a different chemical composition.more » The entire protein sample is utilized in crystallization experiments. Sparse-matrix screening and chemical gradient screening can be combined in one comprehensive 'hybrid' crystallization trial. The technology lends itself well to optimization by high-granularity gradient screening using optimization reagents such as precipitation agents, ligands or cryoprotectants.« less
Lohmander, Stefan; Frobell, Richard B.
2017-01-01
Context: After an anterior cruciate ligament (ACL) injury, a majority of patients have a traumatic bone marrow lesion (BML, or bone bruise). The clinical relevance of posttraumatic lesions remains unclear. Objective: To explore the cross-sectional associations between traumatic BML volume and self-reported knee pain and symptoms among individuals within 4 weeks of ACL injury. Design: Cross-sectional exploratory analysis of a randomized clinical trial. Setting: Orthopaedic departments at 2 hospitals in Sweden. Patients or Other Participants: As part of a randomized trial (knee anterior cruciate ligament nonoperative versus operative treatment [KANON] study), 121 young active adults (74% men, age = 26 ± 5 years, height = 1.8 ± 0.1 m, weight = 76 ± 13 kg) with an ACL tear were studied. Main Outcome Measure(s): The BML volume in the proximal tibia and distal femur was segmented using magnetic resonance images obtained within 4 weeks of injury. A radiologist evaluated the presence of depression fractures on the images. Pain and symptoms of the injured knee (Knee Injury and Osteoarthritis Outcome Score [KOOS] pain and symptoms subscales) were obtained the same day as imaging. We used linear regression models to assess the associations. Results: Most knees had at least 1 BML (96%), and the majority (57%) had a depression fracture. Whole-knee BML volume was not related to knee pain for the entire cohort (β = −0.09, P = .25). Among those without a depression fracture, larger whole-knee BML volume was associated with increased knee pain (β = –0.46, P = .02), whereas no association was found for those with a depression fracture (β = 0.0, P = .96). Larger medial (β = –0.48, P = .02) but not lateral (β = –0.03, P = .77) tibiofemoral BML volume was associated with greater pain. We found no association between BML volume and knee symptoms. Conclusions: We confirmed the absence of relationships between whole-knee BML volume and pain and symptoms within 4 weeks of ACL injury. Our findings extend previous reports in identifying weak associations between larger BML volume in the medial compartment and greater pain and between BML volume and greater pain among those without a depression fracture. PMID:28653872
NASA Technical Reports Server (NTRS)
Bradley, E. S.; Little, B. H.; Warnock, W.; Jenness, C. M.; Wilson, J. M.; Powell, C. W.; Shoaf, L.
1982-01-01
The establishment of propfan technology readiness was determined and candidate drive systems for propfan application were identified. Candidate testbed aircraft were investigated for testbed aircraft suitability and four aircraft selected as possible propfan testbed vehicles. An evaluation of the four candidates was performed and the Boeing KC-135A and the Gulfstream American Gulfstream II recommended as the most suitable aircraft for test application. Conceptual designs of the two recommended aircraft were performed and cost and schedule data for the entire testbed program were generated. The program total cost was estimated and a wind tunnel program cost and schedule is generated in support of the testbed program.
Microwave dielectric study of polar liquids at 298 K
NASA Astrophysics Data System (ADS)
Maharolkar, Aruna P.; Murugkar, A.; Khirade, P. W.
2018-05-01
Present paper deals with study of microwave dielectric properties like dielectric constant, viscosity, density and refractive index for the binary mixtures of Dimethylsulphoxide (DMSO) and Methanol over the entire concentration range were measured at 298K. The experimental data further used to determine the excess properties viz. excess static dielectric constant, excess molar volume, excess viscosity& derived properties viz. molar refraction&Bruggman factor. The values of excess properties further fitted with Redlich-Kister (R-K Fit) equation to calculate the binary coefficients and standard deviation. The resulting excess parameters are used to indicate the presence of intermolecular interactions and strength of intermolecular interactions between the molecules in the binary mixtures. Excess parameters indicate structure breaking factor in the mixture predominates in the system.
Kim, Soo-Yeon; Han, Kyung Hwa; Moon, Hee Jung; Kwak, Jin Young; Chung, Woong Youn; Kim, Eun-Kyung
2014-04-01
To investigate the natural history of thyroid nodules found to be benign at initial fine-needle aspiration biopsy (FNAB) to determine the percentage of nodules that increased in volume by more than 50% as being an indicator of malignancy. This retrospective observational cohort study was approved by the institutional review board, and the need to obtain informed consent was waived. The study included 854 FNAB-confirmed benign thyroid nodules. Suspicious ultrasonographic (US) features included marked hypoechogenicity, irregular or microlobulated margin, microcalcification, and taller-than-wide shape. Univariate and multivariate generalized linear mixed models were used to assess the association with nodule growth greater than 50% in volume. For the 854 nodules, the initial mean diameter was 19.92 mm (range, 3.10-60.00 mm), and the initial mean volume was 3.19 cm(3) (range, 0.01-4.64 cm(3)). The majority (682 [79.9%] of 854) of thyroid nodules with benign cytologic results at initial FNAB did not grow more than 50% in volume during 4 years of mean follow-up (range, 7-101 months). More than 4 years of follow-up time versus less than 2 years, younger age, a cystic component of less than 25%, and nodule size 1 cm or larger versus less than 1 cm were independently associated with growth. There was only one malignant nodule (0.6%) among 172 thyroid nodules with a volume increase of 50% or greater during the entire follow-up time. Ten malignant nodules (overall malignancy rate: 1.2%) were detected among the 854 total nodules, and eight of these 10 nodules showed suspicious features at US. Repeat FNAB for nodules showing more than 50% growth in volume is unlikely to result in a diagnosis of malignancy. A positive FNAB result for malignancy is significantly more likely in the presence of suspicious US features. RSNA, 2014
Xu, Z N
2014-12-01
In this study, an error analysis is performed to study real water drop images and the corresponding numerically generated water drop profiles for three widely used static contact angle algorithms: the circle- and ellipse-fitting algorithms and the axisymmetric drop shape analysis-profile (ADSA-P) algorithm. The results demonstrate the accuracy of the numerically generated drop profiles based on the Laplace equation. A significant number of water drop profiles with different volumes, contact angles, and noise levels are generated, and the influences of the three factors on the accuracies of the three algorithms are systematically investigated. The results reveal that the above-mentioned three algorithms are complementary. In fact, the circle- and ellipse-fitting algorithms show low errors and are highly resistant to noise for water drops with small/medium volumes and contact angles, while for water drop with large volumes and contact angles just the ADSA-P algorithm can meet accuracy requirement. However, this algorithm introduces significant errors in the case of small volumes and contact angles because of its high sensitivity to noise. The critical water drop volumes of the circle- and ellipse-fitting algorithms corresponding to a certain contact angle error are obtained through a significant amount of computation. To improve the precision of the static contact angle measurement, a more accurate algorithm based on a combination of the three algorithms is proposed. Following a systematic investigation, the algorithm selection rule is described in detail, while maintaining the advantages of the three algorithms and overcoming their deficiencies. In general, static contact angles over the entire hydrophobicity range can be accurately evaluated using the proposed algorithm. The ease of erroneous judgment in static contact angle measurements is avoided. The proposed algorithm is validated by a static contact angle evaluation of real and numerically generated water drop images with different hydrophobicity values and volumes.
NASA Astrophysics Data System (ADS)
Rusu, Mirabela; Wang, Haibo; Golden, Thea; Gow, Andrew; Madabhushi, Anant
2013-03-01
Mouse lung models facilitate the investigation of conditions such as chronic inflammation which are associated with common lung diseases. The multi-scale manifestation of lung inflammation prompted us to use multi-scale imaging - both in vivo, ex vivo MRI along with ex vivo histology, for its study in a new quantitative way. Some imaging modalities, such as MRI, are non-invasive and capture macroscopic features of the pathology, while others, e.g. ex vivo histology, depict detailed structures. Registering such multi-modal data to the same spatial coordinates will allow the construction of a comprehensive 3D model to enable the multi-scale study of diseases. Moreover, it may facilitate the identification and definition of quantitative of in vivo imaging signatures for diseases and pathologic processes. We introduce a quantitative, image analytic framework to integrate in vivo MR images of the entire mouse with ex vivo histology of the lung alone, using lung ex vivo MRI as conduit to facilitate their co-registration. In our framework, we first align the MR images by registering the in vivo and ex vivo MRI of the lung using an interactive rigid registration approach. Then we reconstruct the 3D volume of the ex vivo histological specimen by efficient group wise registration of the 2D slices. The resulting 3D histologic volume is subsequently registered to the MRI volumes by interactive rigid registration, directly to the ex vivo MRI, and implicitly to in vivo MRI. Qualitative evaluation of the registration framework was performed by comparing airway tree structures in ex vivo MRI and ex vivo histology where airways are visible and may be annotated. We present a use case for evaluation of our co-registration framework in the context of studying chronic inammation in a diseased mouse.
Förste, Alexander; Pfirrmann, Marco; Sachs, Johannes; Gröger, Roland; Walheim, Stefan; Brinkmann, Falko; Hirtz, Michael; Fuchs, Harald; Schimmel, Thomas
2015-05-01
There are only few quantitative studies commenting on the writing process in dip-pen nanolithography with lipids. Lipids are important carrier ink molecules for the delivery of bio-functional patters in bio-nanotechnology. In order to better understand and control the writing process, more information on the transfer of lipid material from the tip to the substrate is needed. The dependence of the transferred ink volume on the dwell time of the tip on the substrate was investigated by topography measurements with an atomic force microscope (AFM) that is characterized by an ultra-large scan range of 800 × 800 μm(2). For this purpose arrays of dots of the phospholipid1,2-dioleoyl-sn-glycero-3-phosphocholine were written onto planar glass substrates and the resulting pattern was imaged by large scan area AFM. Two writing regimes were identified, characterized of either a steady decline or a constant ink volume transfer per dot feature. For the steady state ink transfer, a linear relationship between the dwell time and the dot volume was determined, which is characterized by a flow rate of about 16 femtoliters per second. A dependence of the ink transport from the length of pauses before and in between writing the structures was observed and should be taken into account during pattern design when aiming at best writing homogeneity. The ultra-large scan range of the utilized AFM allowed for a simultaneous study of the entire preparation area of almost 1 mm(2), yielding good statistic results.
NASA Astrophysics Data System (ADS)
Förste, Alexander; Pfirrmann, Marco; Sachs, Johannes; Gröger, Roland; Walheim, Stefan; Brinkmann, Falko; Hirtz, Michael; Fuchs, Harald; Schimmel, Thomas
2015-05-01
There are only few quantitative studies commenting on the writing process in dip-pen nanolithography with lipids. Lipids are important carrier ink molecules for the delivery of bio-functional patters in bio-nanotechnology. In order to better understand and control the writing process, more information on the transfer of lipid material from the tip to the substrate is needed. The dependence of the transferred ink volume on the dwell time of the tip on the substrate was investigated by topography measurements with an atomic force microscope (AFM) that is characterized by an ultra-large scan range of 800 × 800 μm2. For this purpose arrays of dots of the phospholipid1,2-dioleoyl-sn-glycero-3-phosphocholine were written onto planar glass substrates and the resulting pattern was imaged by large scan area AFM. Two writing regimes were identified, characterized of either a steady decline or a constant ink volume transfer per dot feature. For the steady state ink transfer, a linear relationship between the dwell time and the dot volume was determined, which is characterized by a flow rate of about 16 femtoliters per second. A dependence of the ink transport from the length of pauses before and in between writing the structures was observed and should be taken into account during pattern design when aiming at best writing homogeneity. The ultra-large scan range of the utilized AFM allowed for a simultaneous study of the entire preparation area of almost 1 mm2, yielding good statistic results.
NASA Technical Reports Server (NTRS)
1974-01-01
It is shown in this report that comprehensive in-situ study of all aspects of the entire zone disturbance caused by a body in a flowing plasma resulted in a large number if requirements on the shuttle-PPEPL facility. A large amount of necessary in-situ observation can be obtained by adopting appropriate modes of performing the experiments. Requirements are indicated for worthwhile studies, of some aspects of the problems, which can be carried out effectively while imposing relatively few constraints on the early missions. Considerations for the desired growth and improvement of the PPEPL to facilitate more complete studies in later missions are also discussed. For Vol. 2, see N74-28170; for Vol# 3, see N74-28171.
Total marrow irradiation using Helical TomoTherapy
NASA Astrophysics Data System (ADS)
Garcia-Fernandez, Lourdes Maria
Clinical dose response data of human tumours are limited or restricted to a radiation dose range determined by the level of toxicity to the normal tissues. This is the case for the most common disseminated plasma cell neoplasm, multiple myeloma, where the maximum dose deliverable to the entire bony skeleton using a standard total body irradiation (TBI) technique is limited to about 12 Gy. This study is part of scientific background of a phase I/II dose escalation clinical trial for multiple myeloma using image-guided intensity modulated radiotherapy (IG-IMRT) to deliver high dose to the entire volume of bone marrow with Helical TomoTherapy (HT). This relatively new technology can deliver highly conformal dose distributions to complex target shapes while reducing the dose to critical normal tissues. In this study tools for comparing and predicting the effectiveness of different approaches to total marrow irradiation (TMI) using HT were provided. The expected dose response for plasma cell neoplasms was computed and a radiobiological evaluation of different treatment cohorts in a dose escalating study was performed. Normal tissue complication probability (NTCP) and tumour control probability (TCP) models were applied to an actual TMI treatment plan for a patient and the implications of using different longitudinal field widths were assessed. The optimum dose was ˜39 Gy for which a predicted tumour control of 95% (+/-3%) was obtained, with a predicted 3% (0, 8%) occurrence of radiation pneumonitis. Tissue sparing was seen by using smaller field widths only in the organs of the head. This suggests it would be beneficial to use the small fields in the head only since using small fields for the whole treatment would lead to long treatment times. In TMI it may be necessary to junction two longitudinally adjacent treatment volumes to form a contiguous planning target volume PTV. For instance, this is the case when a different SUP-INF spatial resolution is required or when the PTV length exceeds the bed travel distance. In this work, the dosimetric challenges associated with junctioning longitudinally adjacent PTVs with HT were analyzed and the feasibility of PTV junctioning was demonstrated. The benefits of spatially dividing or splitting the treatment into a few sub-treatments along the longitudinal direction were also investigated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christensen, Gary E.; Song, Joo Hyun; Lu, Wei
2007-06-15
Breathing motion is one of the major limiting factors for reducing dose and irradiation of normal tissue for conventional conformal radiotherapy. This paper describes a relationship between tracking lung motion using spirometry data and image registration of consecutive CT image volumes collected from a multislice CT scanner over multiple breathing periods. Temporal CT sequences from 5 individuals were analyzed in this study. The couch was moved from 11 to 14 different positions to image the entire lung. At each couch position, 15 image volumes were collected over approximately 3 breathing periods. It is assumed that the expansion and contraction ofmore » lung tissue can be modeled as an elastic material. Furthermore, it is assumed that the deformation of the lung is small over one-fifth of a breathing period and therefore the motion of the lung can be adequately modeled using a small deformation linear elastic model. The small deformation inverse consistent linear elastic image registration algorithm is therefore well suited for this problem and was used to register consecutive image scans. The pointwise expansion and compression of lung tissue was measured by computing the Jacobian of the transformations used to register the images. The logarithm of the Jacobian was computed so that expansion and compression of the lung were scaled equally. The log-Jacobian was computed at each voxel in the volume to produce a map of the local expansion and compression of the lung during the breathing period. These log-Jacobian images demonstrate that the lung does not expand uniformly during the breathing period, but rather expands and contracts locally at different rates during inhalation and exhalation. The log-Jacobian numbers were averaged over a cross section of the lung to produce an estimate of the average expansion or compression from one time point to the next and compared to the air flow rate measured by spirometry. In four out of five individuals, the average log-Jacobian value and the air flow rate correlated well (R{sup 2}=0.858 on average for the entire lung). The correlation for the fifth individual was not as good (R{sup 2}=0.377 on average for the entire lung) and can be explained by the small variation in tidal volume for this individual. The correlation of the average log-Jacobian value and the air flow rate for images near the diaphragm correlated well in all five individuals (R{sup 2}=0.943 on average). These preliminary results indicate a strong correlation between the expansion/compression of the lung measured by image registration and the air flow rate measured by spirometry. Predicting the location, motion, and compression/expansion of the tumor and normal tissue using image registration and spirometry could have many important benefits for radiotherapy treatment. These benefits include reducing radiation dose to normal tissue, maximizing dose to the tumor, improving patient care, reducing treatment cost, and increasing patient throughput.« less
Christensen, Gary E; Song, Joo Hyun; Lu, Wei; El Naqa, Issam; Low, Daniel A
2007-06-01
Breathing motion is one of the major limiting factors for reducing dose and irradiation of normal tissue for conventional conformal radiotherapy. This paper describes a relationship between tracking lung motion using spirometry data and image registration of consecutive CT image volumes collected from a multislice CT scanner over multiple breathing periods. Temporal CT sequences from 5 individuals were analyzed in this study. The couch was moved from 11 to 14 different positions to image the entire lung. At each couch position, 15 image volumes were collected over approximately 3 breathing periods. It is assumed that the expansion and contraction of lung tissue can be modeled as an elastic material. Furthermore, it is assumed that the deformation of the lung is small over one-fifth of a breathing period and therefore the motion of the lung can be adequately modeled using a small deformation linear elastic model. The small deformation inverse consistent linear elastic image registration algorithm is therefore well suited for this problem and was used to register consecutive image scans. The pointwise expansion and compression of lung tissue was measured by computing the Jacobian of the transformations used to register the images. The logarithm of the Jacobian was computed so that expansion and compression of the lung were scaled equally. The log-Jacobian was computed at each voxel in the volume to produce a map of the local expansion and compression of the lung during the breathing period. These log-Jacobian images demonstrate that the lung does not expand uniformly during the breathing period, but rather expands and contracts locally at different rates during inhalation and exhalation. The log-Jacobian numbers were averaged over a cross section of the lung to produce an estimate of the average expansion or compression from one time point to the next and compared to the air flow rate measured by spirometry. In four out of five individuals, the average log-Jacobian value and the air flow rate correlated well (R2 = 0.858 on average for the entire lung). The correlation for the fifth individual was not as good (R2 = 0.377 on average for the entire lung) and can be explained by the small variation in tidal volume for this individual. The correlation of the average log-Jacobian value and the air flow rate for images near the diaphragm correlated well in all five individuals (R2 = 0.943 on average). These preliminary results indicate a strong correlation between the expansion/compression of the lung measured by image registration and the air flow rate measured by spirometry. Predicting the location, motion, and compression/expansion of the tumor and normal tissue using image registration and spirometry could have many important benefits for radiotherapy treatment. These benefits include reducing radiation dose to normal tissue, maximizing dose to the tumor, improving patient care, reducing treatment cost, and increasing patient throughput.
The Diuretic Effect in Human Subjects of an Extract of Taraxacum officinale Folium over a Single Day
Clare, Bevin A.; Conroy, Richard S.
2009-01-01
Abstract Background Taraxacum officinale (L.) Weber (Asteraceae) has been extensively employed as a diuretic in traditional folk medicine and in modern phytotherapy in Europe, Asia, and the Americas without prior clinical trial substantiation. Objectives In this pilot study, a high-quality fresh leaf hydroethanolic extract of the medicinal plant T. officinale (dandelion) was ingested by volunteers to investigate whether an increased urinary frequency and volume would result. Design Volume of urinary output and fluid intake were recorded by subjects. Baseline values for urinary frequency and excretion ratio (urination volume:fluid intake) were established 2 days prior to dandelion dosing (8 mL TID) and monitored throughout a 1-day dosing period and 24 hours postdosing. Results For the entire population (n = 17) there was a significant (p < 0.05) increase in the frequency of urination in the 5-hour period after the first dose. There was also a significant (p < 0.001) increase in the excretion ratio in the 5-hour period after the second dose of extract. The third dose failed to change any of the measured parameters. Conclusions Based on these first human data, T. officinale ethanolic extract shows promise as a diuretic in humans. Further studies are needed to establish the value of this herb for induction of diuresis in human subjects. PMID:19678785
ERIC Educational Resources Information Center
US Department of Commerce, 2004
2004-01-01
A census of governments is taken at 5-year intervals as required by law under title 13, United States Codes, Section 161. This 2002 census, similar to those taken since 1957, covers three major subject fields: government organization; public employment; and government finances. This document contains six parts that cover the entire range of state…
Recognition & Response: Developing and Evaluating a Model of RTI for Pre-K
ERIC Educational Resources Information Center
Buysse, Virginia; Peisner-Feinberg, Ellen; Burchinal, Margaret
2012-01-01
The Recognition & Response (R&R) model was developed and is being validated by a research team at the FPG Child Development Institute at the University of North Carolina at Chapel Hill. R&R has generated widespread attention in the early childhood field as a promising RTI model for pre-k (see entire issue of NHSA Dialog, Volume 12[3],…
Fabrication of dual porosity electrode structure
Smith, James L.; Kucera, Eugenia H.
1991-01-01
A substantially entirely fibrous ceramic which may have dual porosity of both micro and macro pores. Total porosity may be 60-75% by volume. A method of spraying a slurry perpendicularly to an ambient stream of air is disclosed along with a method of removing binders without altering the fiber morphology. Adding fine ceramic particulates to the green ceramic fibers enhances the sintering characteristics of the fibers.
Tapping the full potential of geodetic glacier change assessment with air and space borne sensors
NASA Astrophysics Data System (ADS)
Zemp, M.; Paul, F.; Machguth, H.; Fischer, M.
2016-12-01
Glacier changes are recognized as independent and high-confidence natural indicators of climate change. Past, current, and future glacier changes impact on global sea level, the regional water cycle, and local hazard situations. In the 5th Assessment Report of the IPCC, glacier mass budgets were reconciled by combining traditional observations (i.e. results from glaciological and geodetic measurements) with satellite altimetry and gravimetry to fill regional gaps and obtain global coverage. However, this approach is challenged by the relatively small number and inhomogeneous distribution of in-situ measurement series and their often unknown representativeness for the respective mountain range as well as by scale issues of current satellite altimetry (only point data) and gravimetry (coarse resolution) missions. In this presentation, we highlight the potential of air and space borne sensors for (i) validation and calibration of direct measurements using the glaciological method, (ii) assessing glacier volume changes over entire mountain ranges, and for (iii) determination of the representativeness of the field measurements for respective mountain ranges. Whereas long-term in-situ measurements provide the temporal variability of glacier mass changes with annual or seasonal resolution, differencing of high-resolution digital elevation models, such as from airborne (national) surveys or TanDEM-X, bear the potential to assess thickness and volume changes for thousands of individual glaciers over entire mountain ranges on a decadal time scale. In combination, the calibrated field measurements can be used to determine volume and mass changes over entire mountain ranges at high confidence. The spatial-temporal extrapolation can be supported using dense temporal series of snow cover evolution derived from optical satellite data such as Sentinel 2. Finally, these results can be used to reconcile satellite altimetry and gravimetry products. Provided that resources for corresponding glacier monitoring activities are made available (within or outside the scientific funding system), the combination of in-situ with air and space borne measurements will boost the scientific capacity to address the grand challenges from climate-induced glacier changes and related societal impacts.
Radiation Dose-Volume Effects in the Stomach and Small Bowel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kavanagh, Brian D., E-mail: Brian.Kavanagh@ucdenver.ed; Pan, Charlie C.; Dawson, Laura A.
2010-03-01
Published data suggest that the risk of moderately severe (>=Grade 3) radiation-induced acute small-bowel toxicity can be predicted with a threshold model whereby for a given dose level, D, if the volume receiving that dose or greater (VD) exceeds a threshold quantity, the risk of toxicity escalates. Estimates of VD depend on the means of structure segmenting (e.g., V15 = 120 cc if individual bowel loops are outlined or V45 = 195 cc if entire peritoneal potential space of bowel is outlined). A similar predictive model of acute toxicity is not available for stomach. Late small-bowel/stomach toxicity is likely relatedmore » to maximum dose and/or volume threshold parameters qualitatively similar to those related to acute toxicity risk. Concurrent chemotherapy has been associated with a higher risk of acute toxicity, and a history of abdominal surgery has been associated with a higher risk of late toxicity.« less
Carlisle, John A.; Auciello, Orlando; Birrell, James
2006-10-31
An ultrananocrystalline diamond (UNCD) having an average grain size between 3 and 5 nanometers (nm) with not more than about 8% by volume diamond having an average grain size larger than 10 nm. A method of manufacturing UNCD film is also disclosed in which a vapor of acetylene and hydrogen in an inert gas other than He wherein the volume ratio of acetylene to hydrogen is greater than 0.35 and less than 0.85, with the balance being an inert gas, is subjected to a suitable amount of energy to fragment at least some of the acetylene to form a UNCD film having an average grain size of 3 to 5 nm with not more than about 8% by volume diamond having an average grain size larger than 10 nm.
Kanarska, Yuliya; Walton, Otis
2015-11-30
Fluid-granular flows are common phenomena in nature and industry. Here, an efficient computational technique based on the distributed Lagrange multiplier method is utilized to simulate complex fluid-granular flows. Each particle is explicitly resolved on an Eulerian grid as a separate domain, using solid volume fractions. The fluid equations are solved through the entire computational domain, however, Lagrange multiplier constrains are applied inside the particle domain such that the fluid within any volume associated with a solid particle moves as an incompressible rigid body. The particle–particle interactions are implemented using explicit force-displacement interactions for frictional inelastic particles similar to the DEMmore » method with some modifications using the volume of an overlapping region as an input to the contact forces. Here, a parallel implementation of the method is based on the SAMRAI (Structured Adaptive Mesh Refinement Application Infrastructure) library.« less
The dosimetric effects of photon energy on the quality of prostate volumetric modulated arc therapy.
Mattes, Malcolm D; Tai, Cyril; Lee, Alvin; Ashamalla, Hani; Ikoro, N C
2014-01-01
Studies comparing the dosimetric effects of high- and low-energy photons to treat prostate cancer using 3-dimensional conformal and intensity modulated radiation therapy have yielded mixed results. With the advent of newer radiation delivery systems like volumetric modulated arc therapy (VMAT), the impact of changing photon energy is readdressed. Sixty-five patients treated for prostate cancer at our institution from 2011 to 2012 underwent CT simulation. A target volume encompassing the prostate and entire seminal vesicles was treated to 50.4 Gy, followed by a boost to the prostate and proximal seminal vesicles to a total dose of 81 Gy. The VMAT plans were generated for 6-MV and 10-MV photons under identical optimization conditions using the Eclipse system version 8.6 (Varian Medical Systems, Palo Alto, CA). The analytical anisotropic algorithm was used for all dose calculations. Plans were normalized such that 98% of the planning target volume (PTV) received 100% of the prescribed dose. Dose-volumetric data from the treatment planning system was recorded for both 6-MV and 10-MV plans, which were compared for both the entire cohort and subsets of patients stratified according to the anterior-posterior separation. Plans using 10-MV photons had statistically significantly lower relative integral dose (4.1%), gradient measure (4.1%), skin Dmax (16.9%), monitor units (13.0%), and bladder V(30) (3.1%) than plans using 6-MV photons (P < .05). There was no difference in rectal dose, high-dose-region bladder dose, PTV coverage, or conformity index. The benefit of 10-MV photons was more pronounced for thicker patients (anterior-posterior separation >21 cm) for most parameters, with statistically significant differences in bladder V(30), bladder V(65), integral dose, conformity index, and monitor units. The main dosimetric benefits of 10-MV as compared with 6-MV photons are seen in thicker patients, though for the entire cohort 10-MV plans resulted in a lower integral dose, gradient measure, skin Dmax, monitor units, and bladder V(30), possibly at the expense of higher rectum V(81). Copyright © 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wixson, Steve E.
1990-07-01
Transparent Volume Imaging began with the stereo xray in 1895 and ended for most investigators when radiation safety concerns eliminated the second view. Today, similiar images can be generated by the computer without safety hazards providing improved perception and new means of image quantification. A volumetric workstation is under development based on an operational prototype. The workstation consists of multiple symbolic and numeric processors, binocular stereo color display generator with large image memory and liquid crystal shutter, voice input and output, a 3D pointer that uses projection lenses so that structures in 3 space can be touched directly, 3D hard copy using vectograph and lenticular printing, and presentation facilities using stereo 35mm slide and stereo video tape projection. Volumetric software includes a volume window manager, Mayo Clinic's Analyze program and our Digital Stereo Microscope (DSM) algorithms. The DSM uses stereo xray-like projections, rapidly oscillating motion and focal depth cues such that detail can be studied in the spatial context of the entire set of data. Focal depth cues are generated with a lens and apeture algorithm that generates a plane of sharp focus, and multiple stereo pairs each with a different plane of sharp focus are generated and stored in the large memory for interactive selection using a physical or symbolic depth selector. More recent work is studying non-linear focussing. Psychophysical studies are underway to understand how people perce ive images on a volumetric display and how accurately 3 dimensional structures can be quantitated from these displays.
Wang, G J; Wang, Y; Ye, Y; Chen, F; Lu, Y T; Li, S L
2017-11-07
Objective: To investigate the features of apparent diffusion coefficient (ADC) histogram parameters based on entire tumor volume data in high resolution diffusion weighted imaging of nasopharyngeal carcinoma (NPC) and to evaluate its correlations with cancer stages. Methods: This retrospective study included 154 cases of NPC patients[102 males and 52 females, mean age (48±11) years]who had received readout segmentation of long variable echo trains of MRI scan before radiation therapy. The area of tumor was delineated on each section of axial ADC maps to generate ADC histogram by using Image J. ADC histogram of entire tumor along with the histogram parameters-the tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness and kurtosis were obtained by merging all sections with SPSS 22.0 software. Intra-observer repeatability was assessed by using intra-class correlation coefficients (ICC). The patients were subdivided into two groups according to cancer volume: small cancer group (<305 voxels, about 2 cm(3)) and large cancer group (≥2 cm(3)). The correlation between ADC histogram parameters and cancer stages was evaluated with Spearman test. Results: The ICC of measuring ADC histogram parameters of tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness, kurtosis was 0.938, 0.861, 0.885, 0.838, 0.836, 0.358 and 0.456, respectively. The tumor voxels was positively correlated with T staging ( r =0.368, P <0.05). There were significant differences in tumor voxels among patients with different T stages ( K =22.306, P <0.05). There were significant differences in the ADC(mean), ADC(25%), ADC(50%) among patients with different T stages in the small cancer group( K =8.409, 8.187, 8.699, all P <0.05), and the up-mentioned three indices were positively correlated with T staging ( r =0.221, 0.209, 0.235, all P <0.05). Skewness and kurtosis differed significantly between the groups with different cancer volume( t =-2.987, Z =-3.770, both P <0.05). Conclusion: The tumor volume, tissue uniformity of NPC are important factors affecting ADC and cancer stages, parameters of ADC histogram (ADC(mean), ADC(25%), ADC(50%)) increases with T staging in NPC smaller than 2 cm(3).
Increase in mean platelet volume in patients with myocardial bridge.
Bilen, Emine; Tanboga, Ibrahim Halil; Kurt, Mustafa; Kocak, Umran; Ayhan, Huseyin; Keles, Telat; Bozkurt, Engin
2013-01-01
Myocardial bridge is associated with atherosclerosis altered in shear stress and endothelial dysfunction. Mean platelet volume (MPV), a determinant of platelet activation, is shown to be related with atherosclerosis and endothelial dysfunction. In this study, we aimed to evaluate platelet function assessed by MPV in patients with myocardial bridge. Forty-two patients with myocardial bridge in the left anterior descending artery (LAD) and 43 age- and gender-matched healthy participants were included in the study. Myocardial bridging was defined as an intramyocardial systolic compression or milking of a segment of an epicardial coronary artery on angiography. For the entire study population, MPV was measured using an automatic blood counter. The study population consisted of 42 patients with myocardial bridge (52.7 ± 10.2, 76.2% male) and 43 age- and sex-matched healthy control participants (52.1 ± 10.4, 74.4% male). Compared to the control group, MPV value was significantly higher in patients with myocardial bridge (8.9 ± 1.24 vs 8.3 ± 0.78; P = .01). Further, there were no significant differences between groups regarding hemoglobin level, platelet count, fasting blood glucose, and creatinine levels. Our study findings indicated that myocardial bridge is associated with elevated MPV values. Our results might partly explain the increased cardiovascular events in patients with myocardial bridge.
NASA Astrophysics Data System (ADS)
Saris, Anne E. C. M.; Nillesen, Maartje M.; Lopata, Richard G. P.; de Korte, Chris L.
2013-03-01
Automated segmentation of 3D echocardiographic images in patients with congenital heart disease is challenging, because the boundary between blood and cardiac tissue is poorly defined in some regions. Cardiologists mentally incorporate movement of the heart, using temporal coherence of structures to resolve ambiguities. Therefore, we investigated the merit of temporal cross-correlation for automated segmentation over the entire cardiac cycle. Optimal settings for maximum cross-correlation (MCC) calculation, based on a 3D cross-correlation based displacement estimation algorithm, were determined to obtain the best contrast between blood and myocardial tissue over the entire cardiac cycle. Resulting envelope-based as well as RF-based MCC values were used as additional external force in a deformable model approach, to segment the left-ventricular cavity in entire systolic phase. MCC values were tested against, and combined with, adaptive filtered, demodulated RF-data. Segmentation results were compared with manually segmented volumes using a 3D Dice Similarity Index (3DSI). Results in 3D pediatric echocardiographic images sequences (n = 4) demonstrate that incorporation of temporal information improves segmentation. The use of MCC values, either alone or in combination with adaptive filtered, demodulated RF-data, resulted in an increase of the 3DSI in 75% of the cases (average 3DSI increase: 0.71 to 0.82). Results might be further improved by optimizing MCC-contrast locally, in regions with low blood-tissue contrast. Reducing underestimation of the endocardial volume due to MCC processing scheme (choice of window size) and consequential border-misalignment, could also lead to more accurate segmentations. Furthermore, increasing the frame rate will also increase MCC-contrast and thus improve segmentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, D; Kishan, A; Santhanam, A
Purpose: To evaluate the effect of inter- and intra-fractional tumor motion on the error in four-dimensional computed tomography (4DCT) maximal intensity projection (MIP)–based lung tumor internal target volumes (ITV), using deformable image registration of real-time 2D-sagital cine-mode MRI acquired during lung SBRT treatments. Methods: Five lung tumor patients underwent free breathing SBRT treatment on the ViewRay, with dose prescribed to PTV (4DCT MIP-based ITV+3–6mm margin). Sagittal slice cine-MR images (3.5×3.5mm pixels) were acquired through the center of the tumor at 4 frames per second throughout the treatments (3–4 fractions of 21–32 minutes duration). Tumor GTVs were contoured on the firstmore » frame of the cine and tracked throughout the treatment using off-line optical-flow based deformable registration implemented on a GPU cluster. Pseudo-4DCT MIP-based ITVs were generated from MIPs of the deformed GTV contours limited to short segments of image data. All possible pseudo-4DCT MIP-based ITV volumes were generated with 1s resolution and compared to the ITV volume of the entire treatment course. Varying pseudo-4DCT durations from 10-50s were analyzed. Results: Tumors were covered in their entirety by PTV in the patients analysed here. However, pseudo-4DCT based ITV volumes were observed that were as small as 29% of the entire treatment-ITV, depending on breathing irregularity and the duration of pseudo-4DCT. With an increase in duration of pseudo-4DCT from 10–50s the minimum volume acquired from 95% of all pseudo-4DCTs increased from 62%–81% of the treatment ITV. Conclusion: A 4DCT MIP-based ITV offers a ‘snap-shot’ of breathing motion for the brief period of time the tumor is imaged on a specific day. Real time MRI over prolonged periods of time and over multiple treatment fractions shows that the accuracy of this snap-shot varies according to inter- and intra-fractional tumor motion. Further work is required to investigate the dosimetric effect of these results.« less
Sloth Møller, Ditte; Knap, Marianne Marquard; Nyeng, Tine Bisballe; Khalil, Azza Ahmed; Holt, Marianne Ingerslev; Kandi, Maria; Hoffmann, Lone
2017-11-01
Minimizing the planning target volume (PTV) while ensuring sufficient target coverage during the entire respiratory cycle is essential for free-breathing radiotherapy of lung cancer. Different methods are used to incorporate the respiratory motion into the PTV. Fifteen patients were analyzed. Respiration can be included in the target delineation process creating a respiratory GTV, denoted iGTV. Alternatively, the respiratory amplitude (A) can be measured based on the 4D-CT and A can be incorporated in the margin expansion. The GTV expanded by A yielded GTV + resp, which was compared to iGTV in terms of overlap. Three methods for PTV generation were compared. PTV del (delineated iGTV expanded to CTV plus PTV margin), PTV σ (GTV expanded to CTV and A was included as a random uncertainty in the CTV to PTV margin) and PTV ∑ (GTV expanded to CTV, succeeded by CTV linear expansion by A to CTV + resp, which was finally expanded to PTV ∑ ). Deformation of tumor and lymph nodes during respiration resulted in volume changes between the respiratory phases. The overlap between iGTV and GTV + resp showed that on average 7% of iGTV was outside the GTV + resp implying that GTV + resp did not capture the tumor during the full deformable respiration cycle. A comparison of the PTV volumes showed that PTV σ was smallest and PTV Σ largest for all patients. PTV σ was in mean 14% (31 cm 3 ) smaller than PTV del , while PTV del was 7% (20 cm 3 ) smaller than PTV Σ . PTV σ yields the smallest volumes but does not ensure coverage of tumor during the full respiratory motion due to tumor deformation. Incorporating the respiratory motion in the delineation (PTV del ) takes into account the entire respiratory cycle including deformation, but at the cost, however, of larger treatment volumes. PTV Σ should not be used, since it incorporates the disadvantages of both PTV del and PTV σ .
Schulz, Wolfgang; Weiss, Stefan C; Weber, Walter H; Winzenbacher, Rudi
2017-10-13
In effect-directed analysis (EDA) with high-performance thin-layer chromatography (HPTLC), the effect is often detected using images. Thus, an approach to create inhibition chromatograms from these images was developed using the example of the HPTLC- bioluminescence inhibition test. A comparison between the cuvette test and the HPTLC test shows that the test on the plate is significantly more sensitive. To describe the strength of the effect, the EC 50 value is determined from the dose-response relationship. However, the inhibiting compounds are generally unknown and thus their concentrations are also unknown. Therefore, instead of the concentration, the known application volumes are used. This enables the calculation of the application volume necessary to achieve 50% inhibition. Since the volume is inversely proportional to the concentration, the reciprocal value of the calculated volume is indicated and is referred to as the reciprocal iso-inhibition volume (RIV). Using this RIV-concept, it is now possible to compare inhibition bands within and between plates. The entire evaluation is described by the means of two samples from a contaminated site using the bioluminescence inhibition. Copyright © 2017 Elsevier B.V. All rights reserved.
Contemporary bloodletting in cardiac surgical care.
Koch, Colleen G; Reineks, Edmunds Z; Tang, Anne S; Hixson, Eric D; Phillips, Shannon; Sabik, Joseph F; Henderson, J Michael; Blackstone, Eugene H
2015-03-01
Health care providers are seldom aware of the frequency and volume of phlebotomy for laboratory testing, bloodletting that often leads to hospital-acquired anemia. Our objectives were to examine the frequency of laboratory testing in patients undergoing cardiac surgery, calculate cumulative phlebotomy volume from time of initial surgical consultation to hospital discharge, and propose strategies to reduce phlebotomy volume. From January 1, 2012 to June 30, 2012, 1,894 patients underwent cardiac surgery at Cleveland Clinic; 1,867 had 1 hospitalization and 27 had 2. Each laboratory test was associated with a test name and blood volume. Phlebotomy volume was estimated separately for the intensive care unit (ICU), hospital floors, and cumulatively. A total of 221,498 laboratory tests were performed, averaging 115 tests per patient. The most frequently performed tests were 88,068 blood gas analyses, 39,535 coagulation tests, 30,421 complete blood counts, and 29,374 metabolic panels. Phlebotomy volume differed between ICU and hospital floors, with median volumes of 332 mL and 118 mL, respectively. Cumulative median volume for the entire hospital stay was 454 mL. More complex procedures were associated with higher overall phlebotomy volume than isolated procedures; eg, combined coronary artery bypass grafting (CABG) and valve procedure median volume was 653 mL (25th/75th percentiles, 428 of 1,065 mL) versus 448 mL (284 of 658 mL) for isolated CABG and 338 mL (237 of 619) for isolated valve procedures. We were astonished by the extent of bloodletting, with total phlebotomy volumes approaching amounts equivalent to 1 to 2 red blood cell units. Implementation of process improvement initiatives can potentially reduce phlebotomy volumes and resource utilization. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
A CFD Analysis of Hydrogen Leakage During On-Pad Purge in the ORION/ARES I Shared Volume
NASA Technical Reports Server (NTRS)
Ajmani, Kumud; Edwards, Daryl A.
2011-01-01
A common open volume is created by the stacking of the Orion vehicle onto the Ares I Upper Stage. Called the Shared Volume, both vehicles contribute to its gas, fluid, and thermal environment. One of these environments is related to hazardous hydrogen gas. While both vehicles use inert purge gas to mitigate any hazardous gas buildup, there are concerns that hydrogen gas may still accumulate and that the Ares I Hazardous Gas Detection System will not be sufficient for monitoring the integrated volume. This Computational Fluid Dynamics (CFD) analysis has been performed to examine these topics. Results of the analysis conclude that the Ares I Hazardous Gas Detection System will be able to sample the vent effluent containing the highest hydrogen concentrations. A second conclusion is that hydrogen does not accumulate under the Orion Service Module (SM) avionics ring as diffusion and purge flow mixing sufficiently dilute the hydrogen to safe concentrations. Finally the hydrogen concentrations within the Orion SM engine nozzle may slightly exceed the 1 percent volume fraction when the entire worse case maximum full leak is directed vertically into the engine nozzle.
Multiphasic Health Testing in the Clinic Setting
LaDou, Joseph
1971-01-01
The economy of automated multiphasic health testing (amht) activities patterned after the high-volume Kaiser program can be realized in low-volume settings. amht units have been operated at daily volumes of 20 patients in three separate clinical environments. These programs have displayed economics entirely compatible with cost figures published by the established high-volume centers. This experience, plus the expanding capability of small, general purpose, digital computers (minicomputers) indicates that a group of six or more physicians generating 20 laboratory appraisals per day can economically justify a completely automated multiphasic health testing facility. This system would reside in the clinic or hospital where it is used and can be configured to do analyses such as electrocardiography and generate laboratory reports, and communicate with large computer systems in university medical centers. Experience indicates that the most effective means of implementing these benefits of automation is to make them directly available to the medical community with the physician playing the central role. Economic justification of a dedicated computer through low-volume health testing then allows, as a side benefit, automation of administrative as well as other diagnostic activities—for example, patient billing, computer-aided diagnosis, and computer-aided therapeutics. PMID:4935771
Nonlinear lymphangion pressure-volume relationship minimizes edema
Venugopal, Arun M.; Stewart, Randolph H.; Laine, Glen A.
2010-01-01
Lymphangions, the segments of lymphatic vessel between two valves, contract cyclically and actively pump, analogous to cardiac ventricles. Besides having a discernable systole and diastole, lymphangions have a relatively linear end-systolic pressure-volume relationship (with slope Emax) and a nonlinear end-diastolic pressure-volume relationship (with slope Emin). To counter increased microvascular filtration (causing increased lymphatic inlet pressure), lymphangions must respond to modest increases in transmural pressure by increasing pumping. To counter venous hypertension (causing increased lymphatic inlet and outlet pressures), lymphangions must respond to potentially large increases in transmural pressure by maintaining lymph flow. We therefore hypothesized that the nonlinear lymphangion pressure-volume relationship allows transition from a transmural pressure-dependent stroke volume to a transmural pressure-independent stroke volume as transmural pressure increases. To test this hypothesis, we applied a mathematical model based on the time-varying elastance concept typically applied to ventricles (the ratio of pressure to volume cycles periodically from a minimum, Emin, to a maximum, Emax). This model predicted that lymphangions increase stroke volume and stroke work with transmural pressure if Emin < Emax at low transmural pressures, but maintain stroke volume and stroke work if Emin= Emax at higher transmural pressures. Furthermore, at higher transmural pressures, stroke work is evenly distributed among a chain of lymphangions. Model predictions were tested by comparison to previously reported data. Model predictions were consistent with reported lymphangion properties and pressure-flow relationships of entire lymphatic systems. The nonlinear lymphangion pressure-volume relationship therefore minimizes edema resulting from both increased microvascular filtration and venous hypertension. PMID:20601461
Plug-in nanoliter pneumatic liquid dispenser with nozzle design flexibility
Choi, In Ho; Kim, Hojin; Lee, Sanghyun; Baek, Seungbum; Kim, Joonwon
2015-01-01
This paper presents a novel plug-in nanoliter liquid dispensing system with a plug-and-play interface for simple and reversible, yet robust integration of the dispenser. A plug-in type dispenser was developed to facilitate assembly and disassembly with an actuating part through efficient modularization. The entire process for assembly and operation of the plug-in dispenser is performed via the plug-and-play interface in less than a minute without loss of dispensing quality. The minimum volume of droplets pneumatically dispensed using the plug-in dispenser was 124 nl with a coefficient of variation of 1.6%. The dispensed volume increased linearly with the nozzle size. Utilizing this linear relationship, two types of multinozzle dispensers consisting of six parallel channels (emerging from an inlet) and six nozzles were developed to demonstrate a novel strategy for volume gradient dispensing at a single operating condition. The droplet volume dispensed from each nozzle also increased linearly with nozzle size, demonstrating that nozzle size is a dominant factor on dispensed volume, even for multinozzle dispensing. Therefore, the proposed plug-in dispenser enables flexible design of nozzles and reversible integration to dispense droplets with different volumes, depending on the application. Furthermore, to demonstrate the practicality of the proposed dispensing system, we developed a pencil-type dispensing system as an alternative to a conventional pipette for rapid and reliable dispensing of minute volume droplets. PMID:26594263
Plug-in nanoliter pneumatic liquid dispenser with nozzle design flexibility.
Choi, In Ho; Kim, Hojin; Lee, Sanghyun; Baek, Seungbum; Kim, Joonwon
2015-11-01
This paper presents a novel plug-in nanoliter liquid dispensing system with a plug-and-play interface for simple and reversible, yet robust integration of the dispenser. A plug-in type dispenser was developed to facilitate assembly and disassembly with an actuating part through efficient modularization. The entire process for assembly and operation of the plug-in dispenser is performed via the plug-and-play interface in less than a minute without loss of dispensing quality. The minimum volume of droplets pneumatically dispensed using the plug-in dispenser was 124 nl with a coefficient of variation of 1.6%. The dispensed volume increased linearly with the nozzle size. Utilizing this linear relationship, two types of multinozzle dispensers consisting of six parallel channels (emerging from an inlet) and six nozzles were developed to demonstrate a novel strategy for volume gradient dispensing at a single operating condition. The droplet volume dispensed from each nozzle also increased linearly with nozzle size, demonstrating that nozzle size is a dominant factor on dispensed volume, even for multinozzle dispensing. Therefore, the proposed plug-in dispenser enables flexible design of nozzles and reversible integration to dispense droplets with different volumes, depending on the application. Furthermore, to demonstrate the practicality of the proposed dispensing system, we developed a pencil-type dispensing system as an alternative to a conventional pipette for rapid and reliable dispensing of minute volume droplets.
The Proell Effect: A Macroscopic Maxwell's Demon
NASA Astrophysics Data System (ADS)
Rauen, Kenneth M.
2011-12-01
Maxwell's Demon is a legitimate challenge to the Second Law of Thermodynamics when the "demon" is executed via the Proell effect. Thermal energy transfer according to the Kinetic Theory of Heat and Statistical Mechanics that takes place over distances greater than the mean free path of a gas circumvents the microscopic randomness that leads to macroscopic irreversibility. No information is required to sort the particles as no sorting occurs; the entire volume of gas undergoes the same transition. The Proell effect achieves quasi-spontaneous thermal separation without sorting by the perturbation of a heterogeneous constant volume system with displacement and regeneration. The classical analysis of the constant volume process, such as found in the Stirling Cycle, is incomplete and therefore incorrect. There are extra energy flows that classical thermo does not recognize. When a working fluid is displaced across a regenerator with a temperature gradient in a constant volume system, complimentary compression and expansion work takes place that transfers energy between the regenerator and the bulk gas volumes of the hot and cold sides of the constant volume system. Heat capacity at constant pressure applies instead of heat capacity at constant volume. The resultant increase in calculated, recyclable energy allows the Carnot Limit to be exceeded in certain cycles. Super-Carnot heat engines and heat pumps have been designed and a US patent has been awarded.
Cuttino, Laurie W; Arthur, Douglas W; Vicini, Frank; Todor, Dorin; Julian, Thomas; Mukhopadhyay, Nitai
2014-12-01
To describe the long-term outcomes from a completed, multi-institutional phase 4 registry trial using the Contura multilumen balloon (CMLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer. Three hundred forty-two evaluable patients were enrolled by 23 institutions between January 2008 and February 2011. All patients received 34 Gy in 10 fractions, delivered twice daily. Rigorous target coverage and normal tissue dose constraints were observed. The median follow-up time was 36 months (range, 1-54 months). For the entire patient cohort of 342 patients, 10 patients experienced an ipsilateral breast tumor recurrence (IBTR). Eight of these IBTR were classified as true recurrences/marginal miss (TRMM), and 2 were elsewhere failures (EF). Local recurrence-free survival was 97.8% at 3 years. For the entire cohort, 88% of patients had good to excellent overall cosmesis. The overall incidence of infection was 8.5%. Symptomatic seroma was reported in only 4.4% of patients. A separate analysis was performed to determine whether improved outcomes would be observed for patients treated at high-volume centers with extensive brachytherapy experience. Three IBTR were observed in this cohort, only 1 of which was classified as a TRMM. Local recurrence-free survival at high-volume centers was 98.1% at 3 years. Overall cosmetic outcome and toxicity were superior in patients treated at high-volume centers. In these patients, 95% had good to excellent overall cosmesis. Infection was observed in only 2.9% of patients, and symptomatic seroma was reported in only 1.9%. Use of the CMLB for APBI delivery is associated with acceptable long-term local control and toxicity. Local recurrence-free survival was 97.8% at 3 years. Significant (grade 3) toxicity was uncommon, and no grade 4 toxicity was observed. Treatment at high-volume centers was associated with decreased late toxicity. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cuttino, Laurie W., E-mail: lcuttino@mcvh-vcu.edu; Arthur, Douglas W.; Vicini, Frank
2014-12-01
Purpose: To describe the long-term outcomes from a completed, multi-institutional phase 4 registry trial using the Contura multilumen balloon (CMLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer. Methods and Materials: Three hundred forty-two evaluable patients were enrolled by 23 institutions between January 2008 and February 2011. All patients received 34 Gy in 10 fractions, delivered twice daily. Rigorous target coverage and normal tissue dose constraints were observed. Results: The median follow-up time was 36 months (range, 1-54 months). For the entire patient cohort of 342 patients, 10 patients experienced an ipsilateral breast tumor recurrencemore » (IBTR). Eight of these IBTR were classified as true recurrences/marginal miss (TRMM), and 2 were elsewhere failures (EF). Local recurrence-free survival was 97.8% at 3 years. For the entire cohort, 88% of patients had good to excellent overall cosmesis. The overall incidence of infection was 8.5%. Symptomatic seroma was reported in only 4.4% of patients. A separate analysis was performed to determine whether improved outcomes would be observed for patients treated at high-volume centers with extensive brachytherapy experience. Three IBTR were observed in this cohort, only 1 of which was classified as a TRMM. Local recurrence-free survival at high-volume centers was 98.1% at 3 years. Overall cosmetic outcome and toxicity were superior in patients treated at high-volume centers. In these patients, 95% had good to excellent overall cosmesis. Infection was observed in only 2.9% of patients, and symptomatic seroma was reported in only 1.9%. Conclusion: Use of the CMLB for APBI delivery is associated with acceptable long-term local control and toxicity. Local recurrence-free survival was 97.8% at 3 years. Significant (grade 3) toxicity was uncommon, and no grade 4 toxicity was observed. Treatment at high-volume centers was associated with decreased late toxicity.« less
Scott, K.M.; Vallance, J.W.; Kerle, N.; Macias, J.L.; Strauch, W.; Devoli, G.
2005-01-01
A catastrophic lahar began on 30 October 1998, as hurricane precipitation triggered a small flank collapse of Casita volcano, a complex and probably dormant stratovolcano. The initial rockslide-debris avalanche evolved on the flank to yield a watery debris flood with a sediment concentration less than 60 per cent by volume at the base of the volcano. Within 2-5 km, however, the watery flow entrained (bulked) enough sediment to transform entirely to a debris flow. The debris flow, 6 km downstream and 1??2 km wide and 3 to 6 m deep, killed 2500 people, nearly the entire populations of the communities of El Porvenir and Rolando Rodriguez. These 'new towns' were developed in a prehistoric lahar pathway: at least three flows of similar size since 8330 14C years BP are documented by stratigraphy in the same 30-degree sector. Travel time between perception of the flow and destruction of the towns was only 2??5-3??0 minutes. The evolution of the flow wave occurred with hydraulic continuity and without pause or any extraordinary addition of water. The precipitation trigger of the Casita lahar emphasizes the nee d, in volcano hazard assessments, for including the potential for non-eruption-related collapse lahars with the more predictable potential of their syneruption analogues. The flow behaviour emphasizes that volcano collapses can yield not only volcanic debris avalanches with restricted runouts, but also mobile lahars that enlarge by bulking as they flow. Volumes and hence inundation areas of collapse-runout lahars can increase greatly beyond their sources: the volume of the Casita lahar bulked to at least 2??6 times the contributing volume of the flank collapse and 4??2 times that of the debris flood. At least 78 per cent of the debris flow matrix (sediment < -1??0??; 2 mm) was entrained during flow. Copyright c 2004 John Wiley & Sons, Ltd.
Quantifying lung morphology with respiratory-gated micro-CT in a murine model of emphysema
NASA Astrophysics Data System (ADS)
Ford, N. L.; Martin, E. L.; Lewis, J. F.; Veldhuizen, R. A. W.; Holdsworth, D. W.; Drangova, M.
2009-04-01
Non-invasive micro-CT imaging techniques have been developed to investigate lung structure in free-breathing rodents. In this study, we investigate the utility of retrospectively respiratory-gated micro-CT imaging in an emphysema model to determine if anatomical changes could be observed in the image-derived quantitative analysis at two respiratory phases. The emphysema model chosen was a well-characterized, genetically altered model (TIMP-3 knockout mice) that exhibits a homogeneous phenotype. Micro-CT scans of the free-breathing, anaesthetized mice were obtained in 50 s and retrospectively respiratory sorted and reconstructed, providing 3D images representing peak inspiration and end expiration with 0.15 mm isotropic voxel spacing. Anatomical measurements included the volume and CT density of the lungs and the volume of the major airways, along with the diameters of the trachea, left bronchus and right bronchus. From these measurements, functional parameters such as functional residual capacity and tidal volume were calculated. Significant differences between the wild-type and TIMP-3 knockout groups were observed for measurements of CT density over the entire lung, indicating increased air content in the lungs of TIMP-3 knockout mice. These results demonstrate retrospective respiratory-gated micro-CT, providing images at multiple respiratory phases that can be analyzed quantitatively to investigate anatomical changes in murine models of emphysema.
NASA Technical Reports Server (NTRS)
Wray, S. T., Jr.
1973-01-01
The DORMAN program was developed to create and modify a data bank containing data decks which serve as input to the DORCA Computer Program. Via a remote terminal a user can access the bank, extract any data deck, modify that deck, output the modified deck to be input to the DORCA program, and save the modified deck in the data bank. This computer program is an assist in the utilization of the DORCA program. The program is dimensionless and operates almost entirely in integer mode. The program was developed on the CDC 6400/7600 complex for implementation on a UNIVAC 1108 computer.
NASA Technical Reports Server (NTRS)
Greco, R. V.; Eaton, L. R.; Wilkinson, H. C.
1974-01-01
The work is summarized which was accomplished from January 1974 to October 1974 for the Zero-Gravity Atmospheric Cloud Physics Laboratory. The definition and development of an atmospheric cloud physics laboratory and the selection and delineation of candidate experiments that require the unique environment of zero gravity or near zero gravity are reported. The experiment program and the laboratory concept for a Spacelab payload to perform cloud microphysics research are defined. This multimission laboratory is planned to be available to the entire scientific community to utilize in furthering the basic understanding of cloud microphysical processes and phenomenon, thereby contributing to improved weather prediction and ultimately to provide beneficial weather control and modification.
NASA Technical Reports Server (NTRS)
1974-01-01
A detailed analysis is presented of each selected equipment item, and suitability and cost analyses were documented by equipment item. Tradeoffs of alternative specification requirements are presented which include possible relaxation of vibration, material control, fungus and corrosion requirements for experiment equipment. An additional tradeoff was performed to determine whether it is cost effective to modify experiment equipment to be compatible with a 28-volt dc power source rather than the conventional 110-volt ac source. Programmatic analysis data are given which were used as the basis for the extension of results from the analyses of specific equipment items to the entire spacelab experiment program.
Hyperspectral light sheet microscopy
NASA Astrophysics Data System (ADS)
Jahr, Wiebke; Schmid, Benjamin; Schmied, Christopher; Fahrbach, Florian O.; Huisken, Jan
2015-09-01
To study the development and interactions of cells and tissues, multiple fluorescent markers need to be imaged efficiently in a single living organism. Instead of acquiring individual colours sequentially with filters, we created a platform based on line-scanning light sheet microscopy to record the entire spectrum for each pixel in a three-dimensional volume. We evaluated data sets with varying spectral sampling and determined the optimal channel width to be around 5 nm. With the help of these data sets, we show that our setup outperforms filter-based approaches with regard to image quality and discrimination of fluorophores. By spectral unmixing we resolved overlapping fluorophores with up to nanometre resolution and removed autofluorescence in zebrafish and fruit fly embryos.
Hyperspectral light sheet microscopy.
Jahr, Wiebke; Schmid, Benjamin; Schmied, Christopher; Fahrbach, Florian O; Huisken, Jan
2015-09-02
To study the development and interactions of cells and tissues, multiple fluorescent markers need to be imaged efficiently in a single living organism. Instead of acquiring individual colours sequentially with filters, we created a platform based on line-scanning light sheet microscopy to record the entire spectrum for each pixel in a three-dimensional volume. We evaluated data sets with varying spectral sampling and determined the optimal channel width to be around 5 nm. With the help of these data sets, we show that our setup outperforms filter-based approaches with regard to image quality and discrimination of fluorophores. By spectral unmixing we resolved overlapping fluorophores with up to nanometre resolution and removed autofluorescence in zebrafish and fruit fly embryos.
The Coast Artillery Journal. Volume 80, Number 4, July-August 1937
1937-08-01
800 Massachusetts and 200 Connecticut infantry commanded by Colore ! Prescott marched from Cambridge to seize and hold the heights above Charlestown... effectof additional rounds to each man of Prescott’s command. their close-rangefire. Furthermore, many rounds had been allocated to rein- Another...been without food throughout the entire day. Despite these various de- moralizing factors, the corps maintained its discipline. The retirement began
Air Force Civil Engineer, Volume 16, Number 1, 2008
2008-01-01
concrete pavements at any U.S. Air...34 OUT-TO-OUT OF CONCRETE 1’-3" TYP #6 REBAR , TYP, OVERLAP 4’ #6 REBAR , SPACED 15" 3" M IN CO VE R DRILL AND EPOXY COAT WITH OIL PRIOR TO CONCRETE ... concrete portion of the job. The entire project was designed with concrete of varying depths, reinforced with #5 rebar on 1-foot centers.
ERIC Educational Resources Information Center
Adrian, Marlene J., Ed.
This volume contains all research consortium abstracts which were accepted for presentation at the Minneapolis, Minnesota Convention of the American Alliance for Health, Physical Education, Recreation and Dance (AAHPERD), April 7-11, 1983. Abstracts represent "state of the art" research encompassing the entire spectrum of AAHPERD disciplines.…
Medical Surveillance Monthly Report (MSMR). Volume 17, Number 12, December 2010
2010-12-01
overall during the 10- year period was almost entirely (over 92%) attributable to large increases in the rates of lumbar and cervical spondylosis ...months before retirement, active component, U.S. Armed Forces, 2003-2009 _______________2 Osteoarthritis and spondylosis , active component, U.S. Armed...VOL. 17 / NO. 12 Osteoarthritis and Spondylosis , Active Component, U.S. Armed Forces, 2000-2009 Table 1. Incidence counts and rates of osteoarthritis
An all-woman crew to Mars: a radical proposal
NASA Technical Reports Server (NTRS)
Landis, G. A.
2000-01-01
It is logical to propose that if a human mission is flown to Mars, it should be composed of an entirely female crew. On the average, women have lower mass and take less volume than males, and use proportionately less consumables. In addition, sociological research indicates that a female crew may have a preferable interpersonal dynamic, and be likely to choose non-confrontational approaches to solve interpersonal problems.
Fabrication of dual porosity electrode structure
Smith, J.L.; Kucera, E.H.
1991-02-12
A substantially entirely fibrous ceramic is described which may have dual porosity of both micro and macro pores. Total porosity may be 60-75% by volume. A method of spraying a slurry perpendicularly to an ambient stream of air is disclosed along with a method of removing binders without altering the fiber morphology. Adding fine ceramic particulates to the green ceramic fibers enhances the sintering characteristics of the fibers. 3 figures.
A numerical model for the whole Wadden Sea: results on the hydrodynamics
NASA Astrophysics Data System (ADS)
Gräwe, Ulf; Duran-Matute, Matias; Gerkema, Theo; Flöser, Götz; Burchard, Hans
2015-04-01
A high-resolution baroclinic three-dimensional numerical model for the entire Wadden Sea of the German Bight in the southern North Sea is first validated against field data for surface elevation, current velocity, temperature and salinity at selected stations and then used to calculate fluxes of volume, heat and salt inside the Wadden Sea and the exchange between the Wadden Sea and the adjacent North Sea through the major tidal inlets. The General Estuarine Transport Model (GETM) is simulating the reference years 2009-2011. The numerical grid has a resolution of 200x200m and 30 adaptive vertical layers. It is the final stage of a multi-nested setup, starting from the North Atlantic. The atmospheric forcing is taken from the operational forecast of the German Weather Service. Additionally, the freshwater discharge of 23 local rivers and creeks are included. For validation, we use observations from a ship of opportunity measuring sea surface properties, tidal gauge stations, high frequency of salinity and volume transport estimates for the Mardiep and Spiekeroog inlet. Finally, the estuarine overturning circulation in three tidal gulleys is quantified. Regional differences between the gullies are assessed and drivers of the estuarine circulation are identified. Moreover, we will give a consistent estimate of the tidal prisms for all tidal inlets in the entire Wadden Sea.
Rathke, Hendrik; Hamm, Bernd; Guettler, Felix; Lohneis, Philipp; Stroux, Andrea; Suttmeyer, Britta; Jonczyk, Martin; Teichgräber, Ulf; de Bucourt, Maximilian
2015-12-01
In a patient, it is usually not macroscopically possible to estimate the non-viable volume induced by radiofrequency ablation (RFA) after the procedure. The purpose of this study was to use an ex vivo bovine liver model to perform magnetic resonance (MR) volumetry of the visible tissue signal change induced by RFA and to correlate the MR measurement with the actual macroscopic volume measured in the dissected specimens. Sixty-four liver specimens cut from 16 bovine livers were ablated under constant simulated, close physiological conditions with target volumes set to 14.14 ml (3-cm lesion) and 65.45 ml (5-cm lesion). Four commercially available radiofrequency (RF) systems were tested (n=16 for each system; n=8 for 3 cm and n=8 for 5 cm). A T1-weighted turbo spin echo (TSE) sequence with inversion recovery and a proton-density (PD)-weighted TSE sequence were acquired in a 1.0-T open magnetic resonance imaging (MRI) system. After manual dissection, actual macroscopic ablation diameters were measured and volumes calculated. MR volumetry was performed using a semiautomatic software tool. To validate the correctness and feasibility of the volume formula in macroscopic measurements, MR multiplanar reformation diameter measurements with subsequent volume calculation and semiautomatic MR volumes were correlated. Semiautomatic MR volumetry yielded smaller volumes than manual measurement after dissection, irrespective of RF system used, target lesion size, and MR sequence. For the 3-cm lesion, only 43.3% (T1) and 41.5% (PD) of the entire necrosis are detectable. For the 5-cm lesion, only 40.8% (T1) and 37.2% (PD) are visualized in MRI directly after intervention. The correlation between semiautomatic MR volumes and calculated MR volumes was 0.888 for the T1-weighted sequence and 0.875 for the PD sequence. After correlation of semiautomatic MR volumes and calculated MR volumes, it seems reasonable to use the respective volume formula for macroscopic volume calculation. Hyperacute MRI after ex vivo intervention may result in the underestimation of the real expansion of the produced necrosis zone. This must be kept in mind when using MRI for validating ablation success directly after RFA. One reason for the discrepancy between macroscopic and MRI appearance immediately after RFA may be that the transitional zone shows no or only partially visible MR signal change.
NASA Astrophysics Data System (ADS)
Negahdar, Mohammadreza; Zacarias, Albert; Milam, Rebecca A.; Dunlap, Neal; Woo, Shiao Y.; Amini, Amir A.
2012-03-01
The treatment plan evaluation for lung cancer patients involves pre-treatment and post-treatment volume CT imaging of the lung. However, treatment of the tumor volume lung results in structural changes to the lung during the course of treatment. In order to register the pre-treatment volume to post-treatment volume, there is a need to find robust and homologous features which are not affected by the radiation treatment along with a smooth deformation field. Since airways are well-distributed in the entire lung, in this paper, we propose use of airway tree bifurcations for registration of the pre-treatment volume to the post-treatment volume. A dedicated and automated algorithm has been developed that finds corresponding airway bifurcations in both images. To derive the 3-D deformation field, a B-spline transformation model guided by mutual information similarity metric was used to guarantee the smoothness of the transformation while combining global information from bifurcation points. Therefore, the approach combines both global statistical intensity information with local image feature information. Since during normal breathing, the lung undergoes large nonlinear deformations, it is expected that the proposed method would also be applicable to large deformation registration between maximum inhale and maximum exhale images in the same subject. The method has been evaluated by registering 3-D CT volumes at maximum exhale data to all the other temporal volumes in the POPI-model data.
Method and apparatus for measuring volatile compounds in an aqueous solution
Gilmore, Tyler J [Pasco, WA; Cantrell, Kirk J [West Richland, WA
2002-07-16
The present invention is an improvement to the method and apparatus for measuring volatile compounds in an aqueous solution. The apparatus is a chamber with sides and two ends, where the first end is closed. The chamber contains a solution volume of the aqueous solution and a gas that is trapped within the first end of the chamber above the solution volume. The gas defines a head space within the chamber above the solution volume. The chamber may also be a cup with the second end. open and facing down and submerged in the aqueous solution so that the gas defines the head space within the cup above the solution volume. The cup can also be entirely submerged in the aqueous solution. The second end of the. chamber may be closed such that the chamber can be used while resting on a flat surface such as a bench. The improvement is a sparger for mixing the gas with the solution volume. The sparger can be a rotating element such as a propeller on a shaft or a cavitating impeller. The sparger can also be a pump and nozzle where the pump is a liquid pump and the nozzle is a liquid spray nozzle open, to the head space for spraying the solution volume into the head space of gas. The pump could also be a gas pump and the nozzle a gas nozzle submerged in the solution volume for spraying the head space gas into the solution volume.
García-Amado, María; Prensa, Lucía
2012-01-01
Cell number alterations in the amygdaloid complex (AC) might coincide with neurological and psychiatric pathologies with anxiety imbalances as well as with changes in brain functionality during aging. This stereological study focused on estimating, in samples from 7 control individuals aged 20 to 75 years old, the number and density of neurons, glia and endothelial cells in the entire AC and in its 5 nuclear groups (including the basolateral (BL), corticomedial and central groups), 5 nuclei and 13 nuclear subdivisions. The volume and total cell number in these territories were determined on Nissl-stained sections with the Cavalieri principle and the optical fractionator. The AC mean volume was 956 mm(3) and mean cell numbers (x10(6)) were: 15.3 neurons, 60 glial cells and 16.8 endothelial cells. The numbers of endothelial cells and neurons were similar in each AC region and were one fourth the number of glial cells. Analysis of the influence of the individuals' age at death on volume, cell number and density in each of these 24 AC regions suggested that aging does not affect regional size or the amount of glial cells, but that neuron and endothelial cell numbers respectively tended to decrease and increase in territories such as AC or BL. These accurate stereological measures of volume and total cell numbers and densities in the AC of control individuals could serve as appropriate reference values to evaluate subtle alterations in this structure in pathological conditions.
Wang, He; Lu, Shi-Chun; He, Lei; Dong, Jia-Hong
2018-02-01
Liver failure remains as the most common complication and cause of death after hepatectomy, and continues to be a challenge for doctors.t test and χ test were used for single factor analysis of data-related variables, then results were introduced into the model to undergo the multiple factors logistic regression analysis. Pearson correlation analysis was performed for related postoperative indexes, and a diagnostic evaluation was performed using the receiver operating characteristic (ROC) of postoperative indexes.Differences in age, body mass index (BMI), portal vein hypertension, bile duct cancer, total bilirubin, alkaline phosphatase (ALP), gamma-glutamyl transpeptidase (GGT), operation time, cumulative portal vein occlusion time, intraoperative blood volume, residual liver volume (RLV)/entire live rvolume, ascites volume at postoperative day (POD)3, supplemental albumin amount at POD3, hospitalization time after operation, and the prothrombin activity (PTA) were statistically significant. Furthermore, there were significant differences in total bilirubin and the supplemental albumin amount at POD3. ROC analysis of the average PTA, albumin amounts, ascites volume at POD3, and their combined diagnosis were performed, which had diagnostic value for postoperative liver failure (area under the curve (AUC): 0.895, AUC: 0.798, AUC: 0.775, and AUC: 0.903).Preoperative total bilirubin level and the supplemental albumin amount at POD3 were independent risk factors. PTA can be used as the index of postoperative liver failure, and the combined diagnosis of the indexes can improve the early prediction of postoperative liver failure.
Trends in radical prostatectomy: centralization, robotics, and access to urologic cancer care.
Stitzenberg, Karyn B; Wong, Yu-Ning; Nielsen, Matthew E; Egleston, Brian L; Uzzo, Robert G
2012-01-01
Robotic surgery has been widely adopted for radical prostatectomy. We hypothesized that this change is rapidly shifting procedures away from hospitals that do not offer robotics and consequently increasing patient travel. A population-based observational study of all prostatectomies for cancer in New York, New Jersey, and Pennsylvania from 2000 to 2009 was performed using hospital discharge data. Hospital procedure volume was defined as the number of prostatectomies performed for cancer in a given year. Straight-line travel distance to the treating hospital was calculated for each case. Hospitals were contacted to determine the year of acquisition of the first robot. From 2000 to 2009, the total number of prostatectomies performed annually increased substantially. The increase occurred almost entirely at the very high-volume centers (≥ 106 prostatectomies/year). The number of hospitals performing prostatectomy fell 37% from 2000 to 2009. By 2009, the 9% (21/244) of hospitals that had very high volume performed 57% of all prostatectomies, and the 35% (86/244) of hospitals with a robot performed 85% of all prostatectomies. The median travel distance increased 54% from 2000 to 2009 (P<.001). The proportion of patients traveling ≥ 15 miles increased from 24% to 40% (P < .001). Over the past decade, the number of radical prostatectomies performed has risen substantially. These procedures have been increasingly centralized at high-volume centers, leading to longer patient travel distances. Few prostatectomies are now performed at hospitals that do not offer robotic surgery. Copyright © 2011 American Cancer Society.
NASA Astrophysics Data System (ADS)
Soloshenko, I. A.; Tsiolko, V. V.; Pogulay, S. S.; Terent'yeva, A. G.; Bazhenov, V. Yu; Shchedrin, A. I.; Ryabtsev, A. V.; Kuzmichev, A. I.
2007-02-01
In this paper the results of theoretical and experimental studies of the component content of active particles formed in a plasma-chemical reactor composed of a multiple-cell generator of active particles, based on volume barrier discharge, and a working chamber are presented. For calculation of the content of uncharged plasma components an approach is proposed which is based on averaging of the power introduced over the entire volume. Advantages of such an approach lie in an absence of fitting parameters, such as the dimensions of microdischarges, their surface density and rate of breakdown. The calculation and the experiment were accomplished with the use of dry air (20% relative humidity) as the plasma generating medium. Concentrations of O3, HNO3, HNO2, N2 O5 and NO3 were measured experimentally in the discharge volume and working chamber for the residence time of particles on a discharge of 0.3 s and more and discharge specific power of 1.5 W cm-3. It has been determined that the best agreement between the calculation and the experiment occurs at calculated gas medium temperatures in the discharge plasma of about 400-425 K, which correspond to the experimentally measured rotational temperature of nitrogen. In most cases the calculated concentrations of O3, HNO3, HNO2, N2O5 and NO3 for the barrier discharge and the working chamber are in fairly good agreement with the respective measured values.
Stereological Analysis of Neuron, Glial and Endothelial Cell Numbers in the Human Amygdaloid Complex
García-Amado, María; Prensa, Lucía
2012-01-01
Cell number alterations in the amygdaloid complex (AC) might coincide with neurological and psychiatric pathologies with anxiety imbalances as well as with changes in brain functionality during aging. This stereological study focused on estimating, in samples from 7 control individuals aged 20 to 75 years old, the number and density of neurons, glia and endothelial cells in the entire AC and in its 5 nuclear groups (including the basolateral (BL), corticomedial and central groups), 5 nuclei and 13 nuclear subdivisions. The volume and total cell number in these territories were determined on Nissl-stained sections with the Cavalieri principle and the optical fractionator. The AC mean volume was 956 mm3 and mean cell numbers (x106) were: 15.3 neurons, 60 glial cells and 16.8 endothelial cells. The numbers of endothelial cells and neurons were similar in each AC region and were one fourth the number of glial cells. Analysis of the influence of the individuals’ age at death on volume, cell number and density in each of these 24 AC regions suggested that aging does not affect regional size or the amount of glial cells, but that neuron and endothelial cell numbers respectively tended to decrease and increase in territories such as AC or BL. These accurate stereological measures of volume and total cell numbers and densities in the AC of control individuals could serve as appropriate reference values to evaluate subtle alterations in this structure in pathological conditions. PMID:22719923
Morin, Dawn E; Nelson, Stephanie V; Reid, Eric D; Nagy, Dusty W; Dahl, Geoffrey E; Constable, Peter D
2010-08-15
To identify cow and management factors associated with colostral IgG concentration in dairy cows. Prospective observational study. 81 multiparous Holstein-Friesian cows from a single herd. Serum was obtained at the start of the nonlactating period, and cows were assigned to 1 of 4 photoperiod groups: natural day length (n = 22 cows), long days (16 h of light/d [21]) or short days (8 h of light/d [20]) for the entire nonlactating period, or natural day length followed by short days for the last 21 days of the nonlactating period (18). Serum and colostrum were collected at the first milking after calving. Regression analysis was used to investigate associations between colostral IgG concentration and the interval between calving and first milking, colostral volume, photoperiod, length of the nonlactating period, and season of calving. Colostral IgG concentration decreased by 3.7% during each subsequent hour after calving because of postparturient secretion by the mammary glands. The interval between calving and first milking and the colostral volume were significantly and negatively associated with colostral IgG concentration, with the former effect predominating. Photoperiod had no effect on colostral IgG concentration or volume. Serum protein concentration at calving correlated poorly with colostral IgG concentration. Dairy producers should harvest colostrum as soon as possible after calving to optimize transfer of passive immunity in neonatal calves. Photoperiod can be manipulated without adversely affecting colostral IgG concentration.
NASA Astrophysics Data System (ADS)
Sztrókay, A.; Diemoz, P. C.; Schlossbauer, T.; Brun, E.; Bamberg, F.; Mayr, D.; Reiser, M. F.; Bravin, A.; Coan, P.
2012-05-01
Previous studies on phase contrast imaging (PCI) mammography have demonstrated an enhancement of breast morphology and cancerous tissue visualization compared to conventional imaging. We show here the first results of the PCI analyser-based imaging (ABI) in computed tomography (CT) mode on whole and large (>12 cm) tumour-bearing breast tissues. We demonstrate in this work the capability of the technique of working at high x-ray energies and producing high-contrast images of large and complex specimens. One entire breast of an 80-year-old woman with invasive ductal cancer was imaged using ABI-CT with monochromatic 70 keV x-rays and an area detector of 92×92 µm2 pixel size. Sagittal slices were reconstructed from the acquired data, and compared to corresponding histological sections. Comparison with conventional absorption-based CT was also performed. Five blinded radiologists quantitatively evaluated the visual aspects of the ABI-CT images with respect to sharpness, soft tissue contrast, tissue boundaries and the discrimination of different structures/tissues. ABI-CT excellently depicted the entire 3D architecture of the breast volume by providing high-resolution and high-contrast images of the normal and cancerous breast tissues. These results are an important step in the evolution of PCI-CT towards its clinical implementation.
Flowmeter and Ground Penetrating Radar: comparison between hydrogeological and geophysical methods
NASA Astrophysics Data System (ADS)
Villa, A.; Basirico', S.; Arato, A.; Crosta, G. B.; Frattini, P.; Godio, A.
2012-04-01
A comparison between saturated hydraulic conductivity calculated with Electromagnetic Borehole Flowmeter (EBF) and water content obtained by Ground Penetrating Radar (GPR) Zero Offset Profile (ZOP) is presented. EBF technique permits to obtain permeability profiles along one borehole in the saturated zone by using the Moltz (1993) method. The analysis of ZOP data provides information about the water content (Topp, 1980) in the section between two adjacent boreholes. Water content profiles in the saturated zone can be related to the porosity of the medium which, together with the permeability from EBF measurements, is fundamental for any hydrogeological characterization. These two methods have been applied to three different test-sites located in the Northern Italy. A first site regards a complex aquifer, characterized by a chaotic sequence of gypsum-marls. The other two sites are characterized by an alternation of sandy and silty-sandy layers. For each site, we adopted the EBF along screened boreholes with 0.25 m spacing, under ambient and stressed conditions. The cross-hole georadar survey was performed within the saturated zone by using 100 Hz borehole antennas with 0.25 m spacing. The results from the analysis of EBF and ZOP profiles show a general positive correlation between permeability and water content and porosity. This is reasonable for granular soils where the permeability is controlled by the pore space available for water flow, i.e., the effective porosity. For this soils, where EBF permeability and ZOP water-content profiles are in good agreement, the volume between the boreholes can be supposed to be homogeneous. On the other hand, a poor correlation suggests the presence of heterogeneity between the boreholes, which can be observed because the two techniques involve different volumes of soil: the EBF permeability refers to a portion of volume just around the borehole while the ZOP investigates the entire volume between the two boreholes. The poor correlation could be enhanced when enlarging the borehole separation, because the difference in the involved volume between the two techniques increases. Finally, the degree of correlation between the EBF permeability profile and the ZOP water content profile can indicate how much the volume investigated by EBF is effectively representative of the entire volume between the boreholes. Molz, F.J. and S.C. Young, 1993. Development and Application of Borehole Flowmeters for Environmental Assessment, The Log Analyst, 13-23. Topp G.C., J.L. Davis and A.P. Annan, 1980. Electromagnetic determination of soil water content: measurements in coaxial transmission lines, Water Resources Research, 16, 574-582.
NASA Astrophysics Data System (ADS)
Li, Xin; Rooney, William D.; Várallyay, Csanád G.; Gahramanov, Seymur; Muldoon, Leslie L.; Goodman, James A.; Tagge, Ian J.; Selzer, Audrey H.; Pike, Martin M.; Neuwelt, Edward A.; Springer, Charles S.
2010-10-01
The accurate mapping of the tumor blood volume (TBV) fraction ( vb) is a highly desired imaging biometric goal. It is commonly thought that achieving this is difficult, if not impossible, when small molecule contrast reagents (CRs) are used for the T1-weighted (Dynamic-Contrast-Enhanced) DCE-MRI technique. This is because angiogenic malignant tumor vessels allow facile CR extravasation. Here, a three-site equilibrium water exchange model is applied to DCE-MRI data from the cerebrally-implanted rat brain U87 glioma, a tumor exhibiting rapid CR extravasation. Analyses of segments of the (and the entire) DCE data time-course with this "shutter-speed" pharmacokinetic model, which admits finite water exchange kinetics, allow TBV estimation from the first-pass segment. Pairwise parameter determinances were tested with grid searches of 2D parametric error surfaces. Tumor blood volume ( vb), as well as ve (the extracellular, extravascular space volume fraction), and Ktrans (a CR extravasation rate measure) parametric maps are presented. The role of the Patlak Plot in DCE-MRI is also considered.
Neonatal hygroscopic condenser humidifier.
Gedeon, A; Mebius, C; Palmer, K
1987-01-01
A hygroscopic condenser humidifier was developed for neonates on mechanical ventilation and was evaluated by laboratory tests and clinically. Humidification provided by the unit was measured in the 10- to 50-ml tidal-volume range at ambient temperatures of 24 degrees C and 38 degrees C. The effect of a leaking patient connection on device performance was investigated. Leakage rates were measured routinely in a neonatal ICU and surgery to determine the clinical significance. In the entire tidal volume and temperature range, the unit provided an inspiratory water content in excess of 30 g/m3 when the leak fraction (volume leaked/volume delivered at Y-piece) was less than 15%. This was found in three out of four cases. In about one out of ten cases, the leak exceeded 30%, which invariably led to corrective action, such as repositioning or changing the endotracheal tube. However, even at a 30% leak, a water content of about 26 g/m3 was still available for humidifying the inspired gas, which corresponds to normal physiologic conditions found in the trachea for nasal breathing of room air.
Evaluation of the effect of localized skin cooling on nasal airway volume by acoustic rhinometry.
Yamagiwa, M; Hilberg, O; Pedersen, O F; Lundqvist, G R
1990-04-01
Ten healthy subjects (four men and six women) were subjected to localized skin cooling by submersion for 5 min of both feet and, in another experiment, one hand and forearm into ice-cold water. Repeated measurements of nasal cavity volumes by a new method, acoustic rhinometry, showed characteristic patterns ranging from marked increases in volumes lasting the entire exposure period to transient monophasic or biphasic responses to no change at all. The pattern in individual subjects was reproducible with the two methods of cooling, and it could be characterized by five types when related to baseline measurements during the preexposure period. Because of large minute-to-minute variations, probably determined by local differences and fluctuations in blood flow in tissues through the nose, evaluation of induced changes in the nasal cavity volume cannot be based on single measurements as has frequently been done in the past by using rhinomanometry as the experimental method. The mechanisms behind the characteristic patterns in immediate human nasal response to local skin cooling challenge remains to be explored.
Three-Dimensional Geometric Analysis of Felid Limb Bone Allometry
Doube, Michael; Conroy, Alexis Wiktorowicz; Christiansen, Per; Hutchinson, John R.; Shefelbine, Sandra
2009-01-01
Background Studies of bone allometry typically use simple measurements taken in a small number of locations per bone; often the midshaft diameter or joint surface area is compared to body mass or bone length. However, bones must fulfil multiple roles simultaneously with minimum cost to the animal while meeting the structural requirements imposed by behaviour and locomotion, and not exceeding its capacity for adaptation and repair. We use entire bone volumes from the forelimbs and hindlimbs of Felidae (cats) to investigate regional complexities in bone allometry. Method/Principal Findings Computed tomographic (CT) images (16435 slices in 116 stacks) were made of 9 limb bones from each of 13 individuals of 9 feline species ranging in size from domestic cat (Felis catus) to tiger (Panthera tigris). Eleven geometric parameters were calculated for every CT slice and scaling exponents calculated at 5% increments along the entire length of each bone. Three-dimensional moments of inertia were calculated for each bone volume, and spherical radii were measured in the glenoid cavity, humeral head and femoral head. Allometry of the midshaft, moments of inertia and joint radii were determined. Allometry was highly variable and related to local bone function, with joint surfaces and muscle attachment sites generally showing stronger positive allometry than the midshaft. Conclusions/Significance Examining whole bones revealed that bone allometry is strongly affected by regional variations in bone function, presumably through mechanical effects on bone modelling. Bone's phenotypic plasticity may be an advantage during rapid evolutionary divergence by allowing exploitation of the full size range that a morphotype can occupy. Felids show bone allometry rather than postural change across their size range, unlike similar-sized animals. PMID:19270749
Space Science for the 21st Century. Strategic Plan for 1995-2000
NASA Technical Reports Server (NTRS)
1994-01-01
This publication is one of three volumes in 'Space Science for the 21st Century', the Office of Space Science Strategic plan for 1995-2000. The other two volumes are the recently released Integrated Technology Strategy and the Education Plan, which is in preparation at this publication date. The Science Plan was developed by the Office of Space Science (OSS) in partnership with the Space Science Advisory Committee. The mission of the OSS is to seek answers to fundamental questions about: the galaxy and the universe; the connection between the Sun, Earth, and Heliosphere; the origin and evolution of planetary systems; and the origin and distribution of life in the universe. The strategy to answer these questions includes completing the means to survey the universe across the entire electromagnetic spectrum; completing the survey of cosmic rays through their highest energies, and of interstellar gas; carrying out a basic new test of the Theory of General Relativity; completing development of the means to understand the mechanisms of solar variability and its effects on Earth; completing the first exploration of the inner and outer frontiers of the heliosphere; determining the plasma environments of the solar system planets and how those environments are affected by solar activity; completing development of the means to finish the reconnaissance of the entire solar system from the Sun to Pluto; beginning the comprehensive search for other planets around other stars; resuming surface exploration of solar system bodies to understand the origin and evolution of the Sun's planetary system; continuing the study of biogenic compounds and their evolution in the universe; and searching for indicators of past and present conditions conducive to life.
NASA Astrophysics Data System (ADS)
Biba, Nikolay; Alimov, Artem; Shitikov, Andrey; Stebunov, Sergei
2018-05-01
The demand for high performance and energy efficient transportation systems have boosted interest in lightweight design solutions. To achieve maximum weight reductions, it is not enough just to replace steel parts by their aluminium analogues, but it is necessary to change the entire concept of vehicle design. In this case we must develop methods for manufacturing a variety of critical parts with unusual and difficult to produce shapes. The mechanical properties of the material in these parts must also be optimised and tightly controlled to provide the best distribution within the part volume. The only way to achieve these goals is to implement technology development methods based on simulation of the entire manufacturing chain from preparing a billet through the forming operations and heat treatment of the product. The paper presents an approach to such technology development. The simulation of the technological chain starts with extruding a round billet. Depending on the extrusion process parameters, the billet can have different levels of material workout and variation of grain size throughout the volume. After extrusion, the billet gets formed into the required shape in a forging process. The main requirements at this stage are to get the near net shape of the product without defects and to provide proper configuration of grain flow that strengthens the product in the most critical direction. Then the product undergoes solution treatment, quenching and ageing. The simulation of all these stages are performed by QForm FEM code that provides thermo-mechanical coupled deformation of the material during extrusion and forging. To provide microstructure and heat treatment simulation, special subroutines has been developed by the authors. The proposed approach is illustrated by an industrial case study.
Collected software engineering papers, volume 8
NASA Technical Reports Server (NTRS)
1990-01-01
A collection of selected technical papers produced by participants in the Software Engineering Laboratory (SEL) during the period November 1989 through October 1990 is presented. The purpose of the document is to make available, in one reference, some results of SEL research that originally appeared in a number of different forums. Although these papers cover several topics related to software engineering, they do not encompass the entire scope of SEL activities and interests. Additional information about the SEL and its research efforts may be obtained from the sources listed in the bibliography. The seven presented papers are grouped into four major categories: (1) experimental research and evaluation of software measurement; (2) studies on models for software reuse; (3) a software tool evaluation; and (4) Ada technology and studies in the areas of reuse and specification.
In vivo light dosimetry for HPPH-mediated pleural PDT
NASA Astrophysics Data System (ADS)
Dimofte, Andreea; Zhu, Timothy C.; Finlay, Jarod C.; Cullighan, Melissa; Edmonds, Christine E.; Friedberg, Joseph S.; Cengel, Keith; Hahn, Stephen M.
2010-02-01
This study examines the light fluence (rate) delivered to patients undergoing pleural PDT as a function of treatment time, treatment volume and surface area. The accuracy of treatment delivery is analyzed as a function of the calibration accuracies of each isotropic detector and the calibration integrating sphere. The patients studied here are enrolled in a Phase I clinical trial of HPPH-mediated PDT for the treatment of non-small cell lung cancer with pleural effusion. Patients are administered 4mg per kg body weight HPPH 24-48 hours before the surgery. Patients undergoing photodynamic therapy (PDT) are treated with light therapy with a fluence of 15-60 J/cm2 at 661nm. Fluence rate (mW/cm2) and cumulative fluence (J/cm2) is monitored at 7 different sites during the entire light treatment delivery. Isotropic detectors are used for in-vivo light dosimetry. The anisotropy of each isotropic detector was found to be within 15%. The mean fluence rate delivery and treatment time are recorded. A correlation between the treatment time and the treatment volume is established. The result can be used as a clinical guideline for future pleural PDT treatment.
Laboratory study of polymer solutions used for mobility control during in situ NAPL recovery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martel, K.E.; Martel, R.; Lefebvre, R.
1998-12-31
The use of surfactant solutions for the in situ recovery of residual NAPL in aquifers is increasingly considered as a viable remediation technique. The injection of a few pore volumes of high-concentration surfactant solutions can mobilize or solubilize most of the residual NAPL contacted by the solutions. However, the washing solutions` physico-chemical properties (low density and high viscosity), combined with the natural porous media heterogeneity, can prevent a good sweep of the entire contaminated volume. The objective of this laboratory study is first to select and characterize polymers that would be suitable for aquifer restoration. Their experiments showed that amongmore » several polymers, xanthan gum is the most suitable for aquifer remediation. An evaluation of xanthan gum solution rheology was made in order to predict shear rates, xanthan gum concentrations, salinity, and temperature effects on solution viscosity. The second set of experiments were made with a sand box which was designed to reproduce a simple heterogeneous media consisting of layers of sand with different permeability. These tests illustrate the xanthan gum solution`s ability to increase surfactant solution`s sweep efficiency and limit viscous fingering.« less
Transceiver-Phased Arrays for Human Brain Studies at 7 T
2013-01-01
The paper describes technological advances in high-field (7 T) transceiver-phased arrays developed for magnetic resonance imaging of the human brain. The first part of this work describes an 8-element inductively decoupled split elliptical transceiver-phased array with selectable geometry, which provides an easy and efficient way of compensating for changes in mutual inductive coupling associated with difference in loading due to variability in head shape and size. The second part of the work describes a double-row 16-element (2 × 8) transceiver array to extend the homogeneous transmit B1 profile in the longitudinal direction. Multiplexing eight transmit channels between the two rows of the array provides homogeneous excitation over the entire volume. The final section describes design and construction of a double-tuned 31P/1H 16-element (8 at each frequency) array. The array improves transmission efficiency and B1 homogeneity at 1H frequency in comparison with 31P/1H quadrature transverse electromagnetic volume coil. For 31P studies, the array also improves transmission efficiency (38%), signal-to-noise ratio (SNR) for central brain locations (20%) and provides substantially greater SNR (up to 400%) for peripheral locations. PMID:23516332
Roder, Constantin; Breitkopf, Martin; Ms; Bisdas, Sotirios; Freitas, Rousinelle da Silva; Dimostheni, Artemisia; Ebinger, Martin; Wolff, Markus; Tatagiba, Marcos; Schuhmann, Martin U
2016-03-01
Intraoperative MRI (iMRI) is assumed to safely improve the extent of resection (EOR) in patients with gliomas. This study focuses on advantages of this imaging technology in elective low-grade glioma (LGG) surgery in pediatric patients. The surgical results of conventional and 1.5-T iMRI-guided elective LGG surgery in pediatric patients were retrospectively compared. Tumor volumes, general clinical data, EOR according to reference radiology assessment, and progression-free survival (PFS) were analyzed. Sixty-five patients were included in the study, of whom 34 had undergone conventional surgery before the iMRI unit opened (pre-iMRI period) and 31 had undergone surgery with iMRI guidance (iMRI period). Perioperative data were comparable between the 2 cohorts, apart from larger preoperative tumor volumes in the pre-iMRI period, a difference without statistical significance, and (as expected) significantly longer surgeries in the iMRI group. According to 3-month postoperative MRI studies, an intended complete resection (CR) was achieved in 41% (12 of 29) of the patients in the pre-iMRI period and in 71% (17 of 24) of those in the iMRI period (p = 0.05). Of those cases in which the surgeon was postoperatively convinced that he had successfully achieved CR, this proved to be true in only 50% of cases in the pre-iMRI period but in 81% of cases in the iMRI period (p = 0.055). Residual tumor volumes on 3-month postoperative MRI were significantly smaller in the iMRI cohort (p < 0.03). By continuing the resection of residual tumor after the intraoperative scan (when the surgeon assumed that he had achieved CR), the rate of CR was increased from 30% at the time of the scan to 85% at the 3-month postoperative MRI. The mean follow-up for the entire study cohort was 36.9 months (3-79 months). Progression-free survival after surgery was noticeably better for the entire iMRI cohort and in iMRI patients with postoperatively assumed CR, but did not quite reach statistical significance. Moreover, PFS was highly significantly better in patients with CRs than in those with incomplete resections (p < 0.001). Significantly better surgical results (CR) and PFS were achieved after using iMRI in patients in whom total resections were intended. Therefore, the use of high-field iMRI is strongly recommended for electively planned LGG resections in pediatric patients.
Towards Identifying and Reducing the Bias of Disease Information Extracted from Search Engine Data
Huang, Da-Cang; Wang, Jin-Feng; Huang, Ji-Xia; Sui, Daniel Z.; Zhang, Hong-Yan; Hu, Mao-Gui; Xu, Cheng-Dong
2016-01-01
The estimation of disease prevalence in online search engine data (e.g., Google Flu Trends (GFT)) has received a considerable amount of scholarly and public attention in recent years. While the utility of search engine data for disease surveillance has been demonstrated, the scientific community still seeks ways to identify and reduce biases that are embedded in search engine data. The primary goal of this study is to explore new ways of improving the accuracy of disease prevalence estimations by combining traditional disease data with search engine data. A novel method, Biased Sentinel Hospital-based Area Disease Estimation (B-SHADE), is introduced to reduce search engine data bias from a geographical perspective. To monitor search trends on Hand, Foot and Mouth Disease (HFMD) in Guangdong Province, China, we tested our approach by selecting 11 keywords from the Baidu index platform, a Chinese big data analyst similar to GFT. The correlation between the number of real cases and the composite index was 0.8. After decomposing the composite index at the city level, we found that only 10 cities presented a correlation of close to 0.8 or higher. These cities were found to be more stable with respect to search volume, and they were selected as sample cities in order to estimate the search volume of the entire province. After the estimation, the correlation improved from 0.8 to 0.864. After fitting the revised search volume with historical cases, the mean absolute error was 11.19% lower than it was when the original search volume and historical cases were combined. To our knowledge, this is the first study to reduce search engine data bias levels through the use of rigorous spatial sampling strategies. PMID:27271698
Towards Identifying and Reducing the Bias of Disease Information Extracted from Search Engine Data.
Huang, Da-Cang; Wang, Jin-Feng; Huang, Ji-Xia; Sui, Daniel Z; Zhang, Hong-Yan; Hu, Mao-Gui; Xu, Cheng-Dong
2016-06-01
The estimation of disease prevalence in online search engine data (e.g., Google Flu Trends (GFT)) has received a considerable amount of scholarly and public attention in recent years. While the utility of search engine data for disease surveillance has been demonstrated, the scientific community still seeks ways to identify and reduce biases that are embedded in search engine data. The primary goal of this study is to explore new ways of improving the accuracy of disease prevalence estimations by combining traditional disease data with search engine data. A novel method, Biased Sentinel Hospital-based Area Disease Estimation (B-SHADE), is introduced to reduce search engine data bias from a geographical perspective. To monitor search trends on Hand, Foot and Mouth Disease (HFMD) in Guangdong Province, China, we tested our approach by selecting 11 keywords from the Baidu index platform, a Chinese big data analyst similar to GFT. The correlation between the number of real cases and the composite index was 0.8. After decomposing the composite index at the city level, we found that only 10 cities presented a correlation of close to 0.8 or higher. These cities were found to be more stable with respect to search volume, and they were selected as sample cities in order to estimate the search volume of the entire province. After the estimation, the correlation improved from 0.8 to 0.864. After fitting the revised search volume with historical cases, the mean absolute error was 11.19% lower than it was when the original search volume and historical cases were combined. To our knowledge, this is the first study to reduce search engine data bias levels through the use of rigorous spatial sampling strategies.
Kim, Yusung; Tomé, Wolfgang A
2008-01-01
Voxel based iso-Tumor Control Probability (TCP) maps and iso-Complication maps are proposed as a plan-review tool especially for functional image-guided intensity-modulated radiotherapy (IMRT) strategies such as selective boosting (dose painting) and conformal avoidance IMRT. The maps employ voxel-based phenomenological biological dose-response models for target volumes and normal organs. Two IMRT strategies for prostate cancer, namely conventional uniform IMRT delivering an EUD = 84 Gy (equivalent uniform dose) to the entire PTV and selective boosting delivering an EUD = 82 Gy to the entire PTV, are investigated, to illustrate the advantages of this approach over iso-dose maps. Conventional uniform IMRT did yield a more uniform isodose map to the entire PTV while selective boosting did result in a nonuniform isodose map. However, when employing voxel based iso-TCP maps selective boosting exhibited a more uniform tumor control probability map compared to what could be achieved using conventional uniform IMRT, which showed TCP cold spots in high-risk tumor subvolumes despite delivering a higher EUD to the entire PTV. Voxel based iso-Complication maps are presented for rectum and bladder, and their utilization for selective avoidance IMRT strategies are discussed. We believe as the need for functional image guided treatment planning grows, voxel based iso-TCP and iso-Complication maps will become an important tool to assess the integrity of such treatment plans.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amini, Arya; Westerly, David C.; Waxweiler, Timothy V.
Targeted focal therapy strategies for treating single-lobe prostate cancer are under investigation. In this planning study, we investigate the feasibility of treating a portion of the prostate to full-dose external beam radiation with reduced dose to the opposite lobe, compared with full-dose radiation delivered to the entire gland using hypofractionated radiation. For 10 consecutive patients with low- to intermediate-risk prostate cancer, 2 hypofractionated, single-arc volumetric-modulated arc therapy (VMAT) plans were designed. The first plan (standard hypofractionation regimen [STD]) included the entire prostate gland, treated to 70 Gy delivered in 28 fractions. The second dose painting plan (DP) encompassed the involvedmore » lobe treated to 70 Gy delivered in 28 fractions, whereas the opposing, uninvolved lobe received 50.4 Gy in 28 fractions. Mean dose to the opposing neurovascular bundle (NVB) was considerably lower for DP vs STD, with a mean dose of 53.9 vs 72.3 Gy (p < 0.001). Mean penile bulb dose was 18.6 Gy for DP vs 19.2 Gy for STD (p = 0.880). Mean rectal dose was 21.0 Gy for DP vs 22.8 Gy for STD (p = 0.356). Rectum V{sub 70} (the volume receiving ≥70 Gy) was 2.01% for DP vs 2.74% for STD (p = 0.328). Bladder V{sub 70} was 1.69% for DP vs 2.78% for STD (p = 0.232). Planning target volume (PTV) maximum dose points were 76.5 and 76.3 Gy for DP and STD, respectively (p = 0.760). This study demonstrates the feasibility of using VMAT for partial-lobe prostate radiation in patients with prostate cancer involving 1 lobe. Partial-lobe prostate plans appeared to spare adjacent critical structures including the opposite NVB.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baldini, Elizabeth H., E-mail: ebaldini@partners.org; Abrams, Ross A.; Bosch, Walter
Purpose: The purpose of this study was to evaluate the variability in target volume and organ at risk (OAR) contour delineation for retroperitoneal sarcoma (RPS) among 12 sarcoma radiation oncologists. Methods and Materials: Radiation planning computed tomography (CT) scans for 2 cases of RPS were distributed among 12 sarcoma radiation oncologists with instructions for contouring gross tumor volume (GTV), clinical target volume (CTV), high-risk CTV (HR CTV: area judged to be at high risk of resulting in positive margins after resection), and OARs: bowel bag, small bowel, colon, stomach, and duodenum. Analysis of contour agreement was performed using the simultaneousmore » truth and performance level estimation (STAPLE) algorithm and kappa statistics. Results: Ten radiation oncologists contoured both RPS cases, 1 contoured only RPS1, and 1 contoured only RPS2 such that each case was contoured by 11 radiation oncologists. The first case (RPS 1) was a patient with a de-differentiated (DD) liposarcoma (LPS) with a predominant well-differentiated (WD) component, and the second case (RPS 2) was a patient with DD LPS made up almost entirely of a DD component. Contouring agreement for GTV and CTV contours was high. However, the agreement for HR CTVs was only moderate. For OARs, agreement for stomach, bowel bag, small bowel, and colon was high, but agreement for duodenum (distorted by tumor in one of these cases) was fair to moderate. Conclusions: For preoperative treatment of RPS, sarcoma radiation oncologists contoured GTV, CTV, and most OARs with a high level of agreement. HR CTV contours were more variable. Further clarification of this volume with the help of sarcoma surgical oncologists is necessary to reach consensus. More attention to delineation of the duodenum is also needed.« less
Baldini, Elizabeth H.; Abrams, Ross A.; Bosch, Walter; Roberge, David; Haas, Rick L.M.; Catton, Charles N.; Indelicato, Daniel J.; Olsen, Jeffrey R.; Deville, Curtiland; Chen, Yen-Lin; Finkelstein, Steven E.; DeLaney, Thomas F.; Wang, Dian
2015-01-01
Purpose The purpose of this study was to evaluate the variability in target volume and organ at risk (OAR) contour delineation for retroperitoneal sarcoma (RPS) among 12 sarcoma radiation oncologists. Methods and Materials Radiation planning computed tomography (CT) scans for 2 cases of RPS were distributed among 12 sarcoma radiation oncologists with instructions for contouring gross tumor volume (GTV), clinical target volume (CTV), high-risk CTV (HR CTV: area judged to be at high risk of resulting in positive margins after resection), and OARs: bowel bag, small bowel, colon, stomach, and duodenum. Analysis of contour agreement was performed using the simultaneous truth and performance level estimation (STAPLE) algorithm and kappa statistics. Results Ten radiation oncologists contoured both RPS cases, 1 contoured only RPS1, and 1 contoured only RPS2 such that each case was contoured by 11 radiation oncologists. The first case (RPS 1) was a patient with a de-differentiated (DD) liposarcoma (LPS) with a predominant well-differentiated (WD) component, and the second case (RPS 2) was a patient with DD LPS made up almost entirely of a DD component. Contouring agreement for GTV and CTV contours was high. However, the agreement for HR CTVs was only moderate. For OARs, agreement for stomach, bowel bag, small bowel, and colon was high, but agreement for duodenum (distorted by tumor in one of these cases) was fair to moderate. Conclusions For preoperative treatment of RPS, sarcoma radiation oncologists contoured GTV, CTV, and most OARs with a high level of agreement. HR CTV contours were more variable. Further clarification of this volume with the help of sarcoma surgical oncologists is necessary to reach consensus. More attention to delineation of the duodenum is also needed. PMID:26194680
Pulmonary NO and C18O2 uptake during pressure-induced lung expansion in rabbits.
Heller, Hartmut; Schuster, Klaus-Dieter
2007-01-01
In artificially ventilated animals we investigated the dependence of the pulmonary diffusing capacities of nitric oxide (NO) and doubly 18O-labeled carbon dioxide (DLNO, DLC18O2) on lung expansion with respect to ventilator-driven increases in intrapulmonary pressure. For this purpose we applied computerized single-breath experiments to 11 anesthetized paralyzed rabbits (weight 2.8-3.8 kg) at various alveolar volumes (45-72 ml) by studying the almost entire inspiratory limb of the respective pressure/volume curves (intrapulmonary pressure: 6-27 cmH2O). The animals were ventilated with room air, employing a computerized ventilatory servo-system that we designed to maintain mechanical ventilation and to execute the particular lung function tests automatically. Each single-breath maneuver was started from residual volume (13.5+/-2 ml, mean+/-SD) by inflating the rabbit lungs with 35-55 ml indicator gas mixture containing 0.05% NO in N2 or 0.9% C18O2 in N2. Alveolar partial pressures of NO and C18O2 were measured by respiratory mass spectrometry. Values of DLNO and DLC18O2 ranged between 1.55 and 2.49 ml/(mmHg min) and 11.7 and 16.6 ml/(mmHg min), respectively. Linear regression analyses yielded a significant increase in DLNO with simultaneous increase in alveolar volume (P<0.005) and intrapulmonary pressure (P<0.023) whereas DLC18O2 was not improved. Our results suggest that the ventilator-driven lung expansion impaired the C18O2 blood uptake conductance, finally compensating for the beneficial effect of the increase in alveolar volume on DLC18O2 values.
Iwasaki, Tomonori; Takemoto, Yoshihiko; Inada, Emi; Sato, Hideo; Saitoh, Issei; Kakuno, Eriko; Kanomi, Ryuzo; Yamasaki, Youichi
2014-12-01
Pharyngeal airway size is increasingly recognized as an important factor in obstructive sleep apnea. However, few studies have examined the changes of pharyngeal airway form after dental procedures for treating obstructive sleep apnea during growth. The purpose of this study was to evaluate the effect of the Herbst appliance on the 3-dimensional form of the pharyngeal airway using cone-beam computed tomography. Twenty-four Class II subjects (ANB, ≥5°; 11 boys; mean age, 11.6 years) who required Herbst therapy with edgewise treatment had cone-beam computed tomography images taken before and after Herbst treatment. Twenty Class I control subjects (9 boys; mean age, 11.5 years) received edgewise treatment only. The volume, depth, and width of the pharyngeal airway were compared between the groups using measurements from 3-dimensional cone-beam computed tomography images of the entire pharyngeal airway. The increase of the oropharyngeal airway volume in the Herbst group (5000.2 mm(3)) was significantly greater than that of the control group (2451.6 mm(3)). Similarly, the increase of the laryngopharyngeal airway volume in the Herbst group (1941.8 mm(3)) was significantly greater than that of the control group (1060.1 mm(3)). The Herbst appliance enlarges the oropharyngeal and laryngopharyngeal airways. These results may provide a useful assessment of obstructive sleep apnea treatment during growth. Copyright © 2014 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Gray matter abnormalities of the dorsal posterior cingulate in sleep walking.
Heidbreder, Anna; Stefani, Ambra; Brandauer, Elisabeth; Steiger, Ruth; Kremser, Christian; Gizewski, Elke R; Young, Peter; Poewe, Werner; Högl, Birgit; Scherfler, Christoph
2017-08-01
This study aimed to determine whether voxel-based analysis of T1 weighted magnetic resonance imaging (MRI) and diffusion tensor imaging is able to detect alterations of gray and white matter morphometry as well as measures of mean diffusivity and fractional anisotropy in patients with non-rapid eye movement parasomnia. 3 Tesla MRI was performed in 14 drug-free, polysomnography-confirmed adult patients with non-rapid eye movement parasomnia (age: 29 ± 4.2 years; disease duration 19.2 ± 7.7 years) and 14 healthy subjects, matched for age and gender. Statistical parametric mapping was applied to objectively identify focal changes of MRI parameters throughout the entire brain volume. Statistical parametric mapping localized significant decreases of gray matter volume in the left dorsal posterior cingulate cortex (BA23) and posterior midcingulate cortex (BA24) in patients with non-rapid eye movement parasomnias compared to the control group (p < 0.001, corrected for multiple comparisons). No significant differences of mean diffusivity and fractional anisotropy measures were found between the non-rapid eye movement parasomnia group and the healthy control group. Recently, the simultaneous co-existence of arousal or wakefulness originating from the motor and cingulate cortices and persistent sleep in associative cortical regions was suggested as a functional framework of somnambulism. Gray matter volume decline in the dorsal posterior and posterior midcingulate cortex reported in this study might represent the neuroanatomical substrate for this condition. Copyright © 2017 Elsevier B.V. All rights reserved.
Hollingworth, M; Harper, A; Hamer, M
2015-01-01
Most population studies on physical activity and health have involved largely inactive men and women, thus making it difficult to infer if health benefits occur at exercise levels above the current minimum guidelines. The aim was to examine associations between cycling volume and classical cardiovascular risk markers, including hypertension and hypercholesterolemia, in a population sample of habitual cyclists. A nationwide sample comprising 6949 men and women (aged 47.6 years on average) completed questions about their cycling levels, demographics and health. Nearly the entire sample (96.3%) achieved the current minimum physical activity recommendation through cycling alone. There was a dose–response association between cycling volume and risk of diagnosed hypertension (P-trend =0.001), with odds ratios of 0.98 (95% confidence interval (CI), 0.80–1.21), 0.86 (0.70, 1.06), 0.67 (95% CI, 0.53–0.83) across categories of 23–40, 40–61 and >61 metabolic equivalent hours/week (MET-h/week) compared with <23 MET-h/week. These associations persisted in models adjusted for age, sex, smoking, alcohol, body mass index (BMI) and other moderatevigorous physical activities. We also observed inverse associations between cycling volume and other risk factors including BMI and hypercholesterolemia. In summary, results from a population sample of cyclists suggest that additional cardiovascular health benefits can be achieved beyond the current minimum physical activity recommendation. PMID:25273856
2010-01-01
throughout the entire 3D volume which made quantification of the different tissues in the breast possible. The p eaks representing glandular and fat in...coefficients. Keywords: tissue quantification , absolute attenuation coefficient, scatter correction, computed tomography, tomography... tissue types. 1-4 Accurate measurements of t he quantification and di fferentiation of numerous t issues can be useful to identify di sease from
JPRS Report, Soviet Union KOMMUNIST No 1, January 1988.
1988-03-24
the live creativity of the masses is the fundamental factor of the new social system which is being developed currently. The entire people, as...average annual volume of meat produc- tion (in slaughtered weight) increased by 13 percent and that of milk by 9 percent compared with the 11th 5 -year...standards for the 5 -year period is their strength and, in the final account, indi- cates the viability of the new
Sollims Sampler Targeting Peace & Stability Operations Lessons & Best Practices. Volume 1, Issue 1
2010-07-01
training, human trafficking, and civil strife, all of which have damaging spillover effects for the entire world. Second, genocide and mass atrocities...deployed to a conflict or post-conflict area. [ Read More ... ] • The military can be part of a whole-of-government response to threats of genocide and...mass atrocities. Although most militaries do not train specifically for counter- genocide operations, they often have the skills and capabilities to
Fort Riley Building Inventory and Evaluation, 1964-1974: Volume 1 of 2
2017-08-07
Clubhouse Sports Pro Shop 5315 1965 Chapel Chapel 5320 1965 Exchange Service Station Exchange Auto Service 7305 1966 Special Weapons Training ...recognition as an important base of advanced military training . The schools offered theory and practical in- struction in drill and firing practice, stable...management, and horse train - ing. Entire units, not individual men, were sent to Fort Riley to take part in the instruction the schools offered
CTC Sentinel. Volume 5, Issue 7
2012-07-01
vital tourism industry has entirely collapsed while the region is concomitantly suffering a food crisis exacerbated by drought conditions.14 In... words of any entity because God is one without partners. All UNESCO’s calls are just polytheism. We are Muslims and we don’t revere any shrines or...still clung to wrists and faces, from mouths to noses.”15 The throats of the five men had also been slashed open after they Mexican Drug Cartel
1985-08-01
Chino Airport 45,682 Ontario International Airport 122,813 TOTAL 607,859 AF Plant #4 2 a 44,248 Lancaster/Fox Field 72,131 Edwards AFB 111,000 Agua ...Tomatoes "o Spinach o Chile (entire family) These crops produce a gross income of $3,000 to $7,000 per acre per year depending upon the exact crops grown
European Science Notes, Volume 40, Number 7.
1986-07-01
for example, University of i.e., the details of protein-protein, Gbttingen--have departments of biochem- protein-nucleic acid , and nucleic acid ...istry but do not award degrees in bio- nucleic acid interactions and their reg- chemistry.) The Institute for Biochem- ulation is still to be resolved. A...tertiary structure acids structure and function; protein/ of the 5S rRNA molecule--the folding of nucleic- acid interactions; molecular the entire molecule of
NOSS altimeter algorithm specifications
NASA Technical Reports Server (NTRS)
Hancock, D. W.; Forsythe, R. G.; Mcmillan, J. D.
1982-01-01
A description of all algorithms required for altimeter processing is given. Each description includes title, description, inputs/outputs, general algebraic sequences and data volume. All required input/output data files are described and the computer resources required for the entire altimeter processing system were estimated. The majority of the data processing requirements for any radar altimeter of the Seasat-1 type are scoped. Additions and deletions could be made for the specific altimeter products required by other projects.
1990-08-30
concrete-soil-concrete and other soil-filled elements as well as earth embankments of different shapes. The design of the shielding external walls...to vent entirely through the doors. This was required because the large amount of earth fill on the roofs, required for radiation shielding , precluded...Safety Window Shield to Protect Against External Explosions ...... ............... ................... 783 R. L. Shope, W. A. Keenan Strenghtening
Reich, H; Moens, Y; Braun, C; Kneissl, S; Noreikat, K; Reske, A
2014-12-01
Quantitative computer tomographic analysis (qCTA) is an accurate but time intensive method used to quantify volume, mass and aeration of the lungs. The aim of this study was to validate a time efficient interpolation technique for application of qCTA in ponies. Forty-one thoracic computer tomographic (CT) scans obtained from eight anaesthetised ponies positioned in dorsal recumbency were included. Total lung volume and mass and their distribution into four compartments (non-aerated, poorly aerated, normally aerated and hyperaerated; defined based on the attenuation in Hounsfield Units) were determined for the entire lung from all 5 mm thick CT-images, 59 (55-66) per animal. An interpolation technique validated for use in humans was then applied to calculate qCTA results for lung volumes and masses from only 10, 12, and 14 selected CT-images per scan. The time required for both procedures was recorded. Results were compared statistically using the Bland-Altman approach. The bias ± 2 SD for total lung volume calculated from interpolation of 10, 12, and 14 CT-images was -1.2 ± 5.8%, 0.1 ± 3.5%, and 0.0 ± 2.5%, respectively. The corresponding results for total lung mass were -1.1 ± 5.9%, 0.0 ± 3.5%, and 0.0 ± 3.0%. The average time for analysis of one thoracic CT-scan using the interpolation method was 1.5-2 h compared to 8 h for analysis of all images of one complete thoracic CT-scan. The calculation of pulmonary qCTA data by interpolation from 12 CT-images was applicable for equine lung CT-scans and reduced the time required for analysis by 75%. Copyright © 2014 Elsevier Ltd. All rights reserved.
Multiresolution Iterative Reconstruction in High-Resolution Extremity Cone-Beam CT
Cao, Qian; Zbijewski, Wojciech; Sisniega, Alejandro; Yorkston, John; Siewerdsen, Jeffrey H; Stayman, J Webster
2016-01-01
Application of model-based iterative reconstruction (MBIR) to high resolution cone-beam CT (CBCT) is computationally challenging because of the very fine discretization (voxel size <100 µm) of the reconstructed volume. Moreover, standard MBIR techniques require that the complete transaxial support for the acquired projections is reconstructed, thus precluding acceleration by restricting the reconstruction to a region-of-interest. To reduce the computational burden of high resolution MBIR, we propose a multiresolution Penalized-Weighted Least Squares (PWLS) algorithm, where the volume is parameterized as a union of fine and coarse voxel grids as well as selective binning of detector pixels. We introduce a penalty function designed to regularize across the boundaries between the two grids. The algorithm was evaluated in simulation studies emulating an extremity CBCT system and in a physical study on a test-bench. Artifacts arising from the mismatched discretization of the fine and coarse sub-volumes were investigated. The fine grid region was parameterized using 0.15 mm voxels and the voxel size in the coarse grid region was varied by changing a downsampling factor. No significant artifacts were found in either of the regions for downsampling factors of up to 4×. For a typical extremities CBCT volume size, this downsampling corresponds to an acceleration of the reconstruction that is more than five times faster than a brute force solution that applies fine voxel parameterization to the entire volume. For certain configurations of the coarse and fine grid regions, in particular when the boundary between the regions does not cross high attenuation gradients, downsampling factors as high as 10× can be used without introducing artifacts, yielding a ~50× speedup in PWLS. The proposed multiresolution algorithm significantly reduces the computational burden of high resolution iterative CBCT reconstruction and can be extended to other applications of MBIR where computationally expensive, high-fidelity forward models are applied only to a sub-region of the field-of-view. PMID:27694701
Vali, Faisal S; Nagda, Suneel; Hall, William; Sinacore, James; Gao, Mingcheng; Lee, Steven H; Hong, Robert; Shoup, Margaret; Emami, Bahman
2010-11-15
To study various standardized uptake value (SUV)-based approaches to ascertain the best strategy for delineating metabolic tumor volumes (MTV). Twenty-two consecutive previously treated esophageal cancer patients with positron emission tomography (PET) imaging and computed tomography (CT)-based radiotherapy plans were studied. At the level of the tumor epicenter, MTVs were delineated at 11 different thresholds: SUV ≥2, ≥2.5, ≥3, ≥3.5 (SUV(n)); ≥40%, ≥45%, and ≥50% of the maximum (SUV(n%)); and mean liver SUV + 1, 2, 3, and 4 standard deviations (SUV(Lnσ)). The volume ratio and conformality index were determined between MTVs, and the corresponding CT/endoscopic ultrasound-based gross tumor volume (GTV) at the epicenter. Means were analyzed by one-way analysis of variance for repeated measures and further compared using a paired t test for repeated measures. The mean conformality indices ranged from 0.33 to 0.48, being significantly (p < 0.05) closest to 1 at SUV(2.5) (0.47 ± 0.03) and SUV(L4σ) (0.48 ± 0.03). The mean volume ratios ranged from 0.39 to 2.82, being significantly closest to 1 at SUV(2.5) (1.18 ± 0.36) and SUV(L4σ) (1.09 ± 0.15). The mean value of the SUVs calculated using the SUV(L4σ) approach was 2.4. Regardless of the SUV thresholding method used (i.e., absolute or relative to liver mean), a threshold of approximately 2.5 yields the highest conformality index and best approximates the CT-based GTV at the epicenter. These findings may ultimately aid radiation oncologists in the delineation of the entire GTV in esophageal cancer patients. Copyright © 2010 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke
2017-08-01
In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH4+ strategy for ethylene and SO2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO2 from fruits. It was satisfied that trace ethylene and SO2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO2 during the entire LVCC sampling process were proved to be < 4.3% and 2.1% respectively. Good recoveries for ethylene and sulfur dioxide from fruit samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS.
Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke
2017-08-05
In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH 4 + strategy for ethylene and SO 2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO 2 from fruits. It was satisfied that trace ethylene and SO 2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO 2 during the entire LVCC sampling process were proved to be <4.3% and 2.1% respectively. Good recoveries for ethylene and sulfur dioxide from fruit samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS. Copyright © 2017 Elsevier B.V. All rights reserved.
Goff, M.G.; Slyfield, C.R.; Kummari, S.R.; Tkachenko, E.V.; Fischer, S. E.; Yi, Y.H.; Jekir, M.; Keaveny, T.M.; Hernandez, C.J.
2012-01-01
The number and size of resorption cavities in cancellous bone are believed to influence rates of bone loss, local tissue stress and strain and potentially whole bone strength. Traditional two-dimensional approaches to measuring resorption cavities in cancellous bone report the percent of the bone surface covered by cavities or osteoclasts, but cannot measure cavity number or size. Here we use three-dimensional imaging (voxel size 0.7 × 0.7 × 5.0 μm) to characterize resorption cavity location, number and size in human vertebral cancellous bone from nine elderly donors (7 male, 2 female, ages 47–80 years). Cavities were 30.10 ± 8.56 μm in maximum depth, 80.60 ± 22.23 *103 μm2 in surface area and 614.16 ± 311.93 *103 μm3 in volume (mean ± SD). The average number of cavities per unit tissue volume (N.Cv/TV) was 1.25 ± 0.77 mm−3. The ratio of maximum cavity depth to local trabecular thickness was 30.46 ± 7.03 % and maximum cavity depth was greater on thicker trabeculae (p < 0.05, r2 = 0.14). Half of the resorption cavities were located entirely on nodes (the intersection of two or more trabeculae) within the trabecular structure. Cavities that were not entirely on nodes were predominately on plate-like trabeculae oriented in the cranial-caudal (longitudinal) direction. Cavities on plate-like trabeculae were larger in maximum cavity depth, cavity surface area and cavity volume than cavities on rod-like trabeculae (p < 0.05). We conclude from these findings that cavity size and location are related to local trabecular microarchitecture. PMID:22507299
Method and Mchievement of Survey and Evaluation of Groundwater Resources of Guangzhou City
NASA Astrophysics Data System (ADS)
Lin, J.
2017-12-01
Based on the documents and achievements relevant to hydrogeological surveying and mapping of 1:100000, hydrogeological drilling, pumping test and dynamic monitoring of groundwater level in Guangzhou, considering the hydrogeological conditions of Guangzhou and combining the advanced technologies such as remote sensing, the survey and evaluation of the volume of the groundwater resources of Guangzhou was carried out in plain and mountain areas separately. The recharge method was used to evaluate the volume of groundwater resources in plain areas, meanwhile, the output volume and the storage change volume of groundwater were calculated and the volume of groundwater resources was corrected by water balance analysis; while the discharge method was used to evaluated the volume of groundwater resources in mountain areas. The result of survey and evaluation indicates that: the volume of the natural groundwater resources in Guangzhou City is 1.83 billion m3 of which the groundwater replenishment quantity in plain areas is 510,045,000 m3, with a total output of 509,729,000 m3, an absolute balance difference of 316,000 m3 and a relative balance difference of 0.062%; the volume of groundwater resources in mountain areas is 1,358,208,000 m3 including the river basic flow is 965,054,000 m3; the repetitive counted volume of groundwater resources in both plain areas and mountain areas is 38,839,000 m3. This work was realized by refined means for the first time to entirely find out the volume of groundwater resources of Guangzhou City and the law of their distribution so as to lay an important foundation for the protection and reasonable development and exploration of the groundwater resources of Guangzhou City.
NASA Astrophysics Data System (ADS)
Heyes, David M.
1988-04-01
This study evaluates the shear viscosity, self-diffusion coefficient, and thermal conductivity of the Lennard-Jones (LJ) fluid over essentially the entire fluid range by molecular-dynamics (MD) computer simulation. The Green-Kubo (GK) method is mainly used. In addition, for shear viscosity, homogeneous shear nonequilibrium MD (NEMD) is also employed and compared with experimental data on argon along isotherms. Reasonable agreement between GK, NEMD, and experiment is found. Hard-sphere MD modified Chapman-Enskog expressions for these transport coefficients are tested with use of a temperature-dependent effective hard-sphere diameter. Excellent agreement is found for shear viscosity. The thermal conductivity and, more so, self-diffusion coefficient is less successful in this respect. This behavior is attributed to the attractive part to the LJ potential and its soft repulsive core. Expressions for the constant-volume and -pressure activation energies for these transport coefficients are derived solely in terms of the thermodynamic properties of the LJ fluid. Also similar expressions for the activation volumes are given, which should have a wider range of applications than just for the LJ system.
Arias, Ana; Paqué, Frank; Shyn, Stephanie; Murphy, Sarah; Peters, Ove A
2018-04-01
The purpose of this study was to assess the geometry of non-round root canals after preparation with TRUShape (a novel instrument with s-shaped longitudinal design) in comparison to conventional rotary instrumentation using micro-computed tomography. Twenty distal root canals of mandibular molars were randomly distributed in two groups to be shaped with either TRUShape or Vortex rotaries. Percentages of unprepared surface and volume of dentin removal for the entire canal and for the apical 4 mm were calculated. Canal transportation and the structure model index (SMI) were assessed. Data were compared with Student t-tests. Shaping with both techniques resulted in similar prepared surface and volume of dentin removed, as well as the extent of canal transportation. The SMI shape factor was significantly lower for TRUShape preparations (P = 0.04) suggesting less rounding during rotary preparation. Although both instruments were suitable for the preparation of oval canals, TRUShape appeared to better conform to the original ribbon-shaped anatomy. © 2017 Australian Society of Endodontology Inc.
Application and assessment of a robust elastic motion correction algorithm to dynamic MRI.
Herrmann, K-H; Wurdinger, S; Fischer, D R; Krumbein, I; Schmitt, M; Hermosillo, G; Chaudhuri, K; Krishnan, A; Salganicoff, M; Kaiser, W A; Reichenbach, J R
2007-01-01
The purpose of this study was to assess the performance of a new motion correction algorithm. Twenty-five dynamic MR mammography (MRM) data sets and 25 contrast-enhanced three-dimensional peripheral MR angiographic (MRA) data sets which were affected by patient motion of varying severeness were selected retrospectively from routine examinations. Anonymized data were registered by a new experimental elastic motion correction algorithm. The algorithm works by computing a similarity measure for the two volumes that takes into account expected signal changes due to the presence of a contrast agent while penalizing other signal changes caused by patient motion. A conjugate gradient method is used to find the best possible set of motion parameters that maximizes the similarity measures across the entire volume. Images before and after correction were visually evaluated and scored by experienced radiologists with respect to reduction of motion, improvement of image quality, disappearance of existing lesions or creation of artifactual lesions. It was found that the correction improves image quality (76% for MRM and 96% for MRA) and diagnosability (60% for MRM and 96% for MRA).
A study for the installation of the TEXT heavy-ion beam probe on DIII-D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edmonds, P.H.; Solano, E.R.; Bravenec, R.V.
1997-01-01
An assessment of the feasibility of installing the TEXT 2 MeV heavy-ion beam probe on the DIII-D tokamak has been completed. Detailed drawings of the machine cross section were imported into the CAD application AutoCAD. A set of programs written in AutoLisp were used to generate trajectories. Displays of the accessible cross section of the plasma, scan lines for the entire range of primary beam energy and injection angle ranges, and sample{endash}volume dimensions can be rapidly generated. Because of the large deflection between the primary input beam and the emergent secondary beam, either the analyzer needs to be tracked overmore » a {plus_minus}20{degree} angle or secondary poloidal deflector plates need to be installed at the exit port. Toroidal deflector plates will be installed at both the injection and exit ports to compensate for toroidal displacements and deflections. The sample volumes generated by this procedure are within a few centimeters of the locations derived from a full three-dimensional calculation.{copyright} {ital 1997 American Institute of Physics.}« less
Development of a Hydrodynamic Model of Puget Sound and Northwest Straits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Zhaoqing; Khangaonkar, Tarang P.
2007-12-10
The hydrodynamic model used in this study is the Finite Volume Coastal Ocean Model (FVCOM) developed by the University of Massachusetts at Dartmouth. The unstructured grid and finite volume framework, as well as the capability of wetting/drying simulation and baroclinic simulation, makes FVCOM a good fit to the modeling needs for nearshore restoration in Puget Sound. The model domain covers the entire Puget Sound, Strait of Juan de Fuca, San Juan Passages, and Georgia Strait at the United States-Canada Border. The model is driven by tide, freshwater discharge, and surface wind. Preliminary model validation was conducted for tides at variousmore » locations in the straits and Puget Sound using National Oceanic and Atmospheric Administration (NOAA) tide data. The hydrodynamic model was successfully linked to the NOAA oil spill model General NOAA Operational Modeling Environment model (GNOME) to predict particle trajectories at various locations in Puget Sound. Model results demonstrated that the Puget Sound GNOME model is a useful tool to obtain first-hand information for emergency response such as oil spill and fish migration pathways.« less
Alam, Murad; Sadhwani, Divya; Geisler, Amelia; Aslam, Imran; Makin, Inder Raj S; Schlessinger, Daniel I; Disphanurat, Wareeporn; Pongprutthipan, Marisa; Voravutinon, Nataya; Weil, Alexandra; Chen, Brian R; West, Dennis P; Veledar, Emir; Poon, Emily
2018-04-23
Non-invasive fat removal is preferred because of decreased downtime and lower perceived risk. It is important to seek new non-invasive fat removal treatments that are both safe and efficacious. To assess the extent to which carboxytherapy, the insufflation of carbon dioxide gas into subcutaneous fat, results in reduction of fat volume. Randomized, sham-controlled, split-body study. Adults (BMI 22-29) were randomized to receive five weekly infusions of 1000 cc CO 2 to one side of the abdomen, and five sham treatments to the contralateral side. Primary outcome measures were ultrasound measurement of fat layer thickness, as well as total circumference before and after treatment. Sixteen participants completed the study. Ultrasound measurement indicated less fat volume on the sides treated with carboxytherapy one week after the last treatment, (p=0.011), but was not maintained at 28 weeks. Total circumference decreased nominally but not significantly at Week 5 compared to baseline (p=0.0697). Participant body weights did not change over the entire course of the study (p=1.00) LIMITATIONS: Limitations included modest sample size and some sources of error in circumference and fat layer measurements. Carboxytherapy provides a transient decrease in subcutaneous fat that may not persist. Treatment is well-tolerated. Copyright © 2018. Published by Elsevier Inc.
Novel spirometry based on optical surface imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Guang, E-mail: lig2@mskcc.org; Huang, Hailiang; Li, Diana G.
2015-04-15
Purpose: To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. Methods: We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and threemore » healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4–5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house MATLAB program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔV{sub torso} = ΔV{sub thorax} + ΔV{sub abdomen}) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BP{sub v} = ΔV{sub thorax}/ΔV{sub torso}) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another MATLAB program was implemented to control the conventional spirometer that was used as the standard. Results: The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range −1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume differences measured using OSI imaging and CT imaging were 1.2% ± 2.1% (range −0.5% to 3.6%), with a linear regression fitting (slope = 1.02 and R{sup 2} = 0.999). In volunteers, the relative error in OSI tidal volume measurement was −2.2% ± 4.9% (range −9.2% to 4.8%) and a correlation of r = 0.98 was found with spirometric measurement. The breathing pattern values of the three volunteers were substantially different from each other (BP{sub v} = 0.15, 0.45, and 0.32). Conclusions: This study demonstrates the feasibility of using OSI to measure breathing tidal volumes and breathing patterns with adequate accuracy. This is the first time that dynamic breathing tidal volume as well as breathing patterns is measured using optical surface imaging. The OSI-observed movement of the entire torso could serve as a new respiratory surrogate in the treatment room during radiation therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gloudemans, J.R.
1991-08-01
The multiloop integral system test (MIST) was part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock Wilcox-designed plants. MIST was sponsored by the US Nuclear Regulatory Commission, the Babcock Wilcox Owners Group, the Electric Power Research Institute, and Babcock Wilcox. The unique features of the Babcock Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral system facilities to addresss the thermal-hydraulic SBLOCA questions. MIST was specifically designed and constructed for this program, and an existing facility -- the once-through integralmore » system (OTIS) -- was also used. Data from MIST and OTIS are used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The MIST program is reported in eleven volumes; Volumes 2 through 8 pertain to groups of Phase 3 tests by type, Volume 9 presents inter-group comparisons. Volume 10 provides comparisons between the RELAP5 MOD2 calculations and MIST observations, and Volume 11 (with addendum) presents the later, Phase 4 tests. This is Volume 1 of the MIST final report, a summary of the entire MIST program. Major topics include: test advisory grop (TAG) issues; facility scaling and design; test matrix; observations; comparisons of RELAP5 calculations to MIST observations; and MIST versus the TAG issues. 11 refs., 29 figs., 9 tabs.« less
Transrectal real-time elastography of the prostate: Normal patterns
Goddi, A.; Sacchi, A.; Magistretti, G.; Almolla, J.
2011-01-01
Introduction Given the growing importance in clinical practice of transrectal real-time sonoelastography of the prostate, it is important to define normal patterns correlated to volume growth and reconsider the technical problems. Materials and methods We selected a sample of 100 men aged 30 to 87 with prostate volumes ranging from 20 to 100 cc. Strain images were obtained using an end-fire convex probe. The elasticity patterns of the various anatomical zones of the prostate were compared with the volume. Results The peripheral zone showed intermediate elasticity in 100% of cases regardless of the volume. We found some rare small areas of more limited elasticity in 23% of cases, among patients over 40. The posterior side of the central zone exhibited intermediate elasticity, and relative inelasticity was observed on the lateral side and at the base in 79% of cases. The entire central zone appeared compliant in 15% of cases and inelastic in 6%. The transition zone findings were stratified according to gland volume. When the volume was less than 45 cc, the transition zone was elastic in 67% of cases, inhomogeneously inelastic in 22%, and uniformly inelastic in 11%. In glands larger than 45 cc, the appearance was mainly elastic in 31% of cases, inhomogeneously inelastic in 57%, and uniformly inelastic in 12%. Conclusions Real-time elastography can distinguish the elastic properties of the prostate and define the normal patterns associated with increases in gland volume. PMID:23396618
González-Badillo, Juan José; Izquierdo, Mikel; Gorostiaga, Esteban M
2006-02-01
The purpose of this study was to examine the effect of 3 volumes of heavy resistance, average relative training intensity (expressed as a percentage of 1 repetition maximum that represented the absolute kilograms lifted divided by the number of repetitions performed) programs on maximal strength (1RM) in Snatch (Sn), Clean & Jerk (C&J), and Squat (Sq). Twenty-nine experienced (>3 years), trained junior weightlifters were randomly assigned into 1 of 3 groups: low-intensity group (LIG; n = 12), moderate-intensity group (MIG; n = 9), and high-intensity group (HIG; n = 8). All subjects trained for 10 weeks, 4-5 days a week, in a periodized routine using the same exercises and training volume (expressed as total number of repetitions performed at intensities equal to or greater than 60% of 1RM), but different programmed total repetitions at intensities of >90-100% of 1RM for the entire 10-week period: LIG (46 repetitions), MIG (93 repetitions), and HIG (184 repetitions). During the training period, MIG and LIG showed a significant increase (p < 0.01-0.05) for C&J (10.5% and 3% for MIG and LIG, respectively) and Sq (9.5% and 5.3% for MIG and LIG, respectively), whereas in HIG the increase took place only in Sq (6.9%, p < 0.05). A calculation of effect sizes revealed greater strength gains in the MIG than in HIG or LIG. There were no significant differences between LIG and HIG training volume-induced strength gains. All the subjects in HIG were unable to fully accomplish the repetitions programmed at relative intensities greater than 90% of 1RM. The present results indicate that short-term resistance training using moderate volumes of high relative intensity tended to produce higher enhancements in weightlifting performance compared with low and high volumes of high relative training intensities of equal total volume in experienced, trained young weightlifters. Therefore, for the present population of weightlifters, it may be beneficial to use the MIG training protocol to improve the weightlifting program at least in a short-term (10 weeks) cycle of training.
Powell, Nathaniel J; Jang, Albert; Park, Jang-Yeon; Valette, Julien; Garwood, Michael; Marjańska, Małgorzata
2015-01-01
To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing the entire outer volume. Theoretical and k-space descriptions of GROOVE are provided. The properties of GROOVE were investigated with simulations, phantom, and human experiments performed using a 4T horizontal bore magnet equipped with a TEM coil. Similar suppression performance was obtained in phantom and human brain using GROOVE with circular and elliptical shapes. Simulations indicate that GROOVE requires less SAR and time than traditional OVS schemes, but traditional schemes provide a sharper transition zone and less residual signal. GROOVE represents a new way of performing OVS in which spins are excited temporally in space on a trajectory that can be tailored to fit the shape of the suppression region. In addition, GROOVE is capable of suppressing tailored regions of space with more flexibility and in a shorter period of time than conventional methods. GROOVE provides a fast, low SAR alternative to conventional OVS methods in some applications (e.g., scalp suppression). © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Georgiadis, A.; Berg, S.; Makurat, A.; Maitland, G.; Ott, H.
2013-09-01
We investigated the cluster-size distribution of the residual nonwetting phase in a sintered glass-bead porous medium at two-phase flow conditions, by means of micro-computed-tomography (μCT) imaging with pore-scale resolution. Cluster-size distribution functions and cluster volumes were obtained by image analysis for a range of injected pore volumes under both imbibition and drainage conditions; the field of view was larger than the porosity-based representative elementary volume (REV). We did not attempt to make a definition for a two-phase REV but used the nonwetting-phase cluster-size distribution as an indicator. Most of the nonwetting-phase total volume was found to be contained in clusters that were one to two orders of magnitude larger than the porosity-based REV. The largest observed clusters in fact ranged in volume from 65% to 99% of the entire nonwetting phase in the field of view. As a consequence, the largest clusters observed were statistically not represented and were found to be smaller than the estimated maximum cluster length. The results indicate that the two-phase REV is larger than the field of view attainable by μCT scanning, at a resolution which allows for the accurate determination of cluster connectivity.
A Structural Molar Volume Model for Oxide Melts Part III: Fe Oxide-Containing Melts
NASA Astrophysics Data System (ADS)
Thibodeau, Eric; Gheribi, Aimen E.; Jung, In-Ho
2016-04-01
As part III of this series, the model is extended to iron oxide-containing melts. All available experimental data in the FeO-Fe2O3-Na2O-K2O-MgO-CaO-MnO-Al2O3-SiO2 system were critically evaluated based on the experimental condition. The variations of FeO and Fe2O3 in the melts were taken into account by using FactSage to calculate the Fe2+/Fe3+ distribution. The molar volume model with unary and binary model parameters can be used to predict the molar volume of the molten oxide of the Li2O-Na2O-K2O-MgO-CaO-MnO-PbO-FeO-Fe2O3-Al2O3-SiO2 system in the entire range of compositions, temperatures, and oxygen partial pressures from Fe saturation to 1 atm pressure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1978-05-01
The Transient Reactor Analysis Code (TRAC) is being developed at the Los Alamos Scientific Laboratory (LASL) to provide an advanced ''best estimate'' predictive capability for the analysis of postulated accidents in light water reactors (LWRs). TRAC-Pl provides this analysis capability for pressurized water reactors (PWRs) and for a wide variety of thermal-hydraulic experimental facilities. It features a three-dimensional treatment of the pressure vessel and associated internals; two-phase nonequilibrium hydrodynamics models; flow-regime-dependent constitutive equation treatment; reflood tracking capability for both bottom flood and falling film quench fronts; and consistent treatment of entire accident sequences including the generation of consistent initial conditions.more » The TRAC-Pl User's Manual is composed of two separate volumes. Volume I gives a description of the thermal-hydraulic models and numerical solution methods used in the code. Detailed programming and user information is also provided. Volume II presents the results of the developmental verification calculations.« less
Interdisciplinary Social Science: An Example of Vertical and Horizontal Integrative Strategies
NASA Astrophysics Data System (ADS)
Durlabhji, Subhash
2005-03-01
A "Concept-Centered" strategy for Integrative Studies was proposed and implemented in the creation of the book Power in Focus: Perspectives from Multiple Disciplines. Essays on the ubiquitous concept of Power were solicited internationally and a final cut of ten essays from ten different disciplines, written specifically for this project, were included. This provides an example of what might be called Horizontal Integration, as it cut across multiple disciplines. One of the essays in the volume provides an example of Vertical Integration, as it applies a psychodynamic hypothesis concerning the development of Power relations among humans across hierarchical levels, from the child to the family to other groups and institutions in society, including finally entire nations and regions of the world.
Nelson, D A; Curlee, J S; Curran, A R; Ziriax, J M; Mason, P A
2005-12-01
The localized thermal insulation value expresses a garment's thermal resistance over the region which is covered by the garment, rather than over the entire surface of a subject or manikin. The determination of localized garment insulation values is critical to the development of high-resolution models of sensible heat exchange. A method is presented for determining and validating localized garment insulation values, based on whole-body insulation values (clo units) and using computer-aided design and thermal analysis software. Localized insulation values are presented for a catalog consisting of 106 garments and verified using computer-generated models. The values presented are suitable for use on volume element-based or surface element-based models of heat transfer involving clothed subjects.
Polymer-Fourier quantization of the scalar field revisited
NASA Astrophysics Data System (ADS)
Garcia-Chung, Angel; Vergara, J. David
2016-10-01
The polymer quantization of the Fourier modes of the real scalar field is studied within algebraic scheme. We replace the positive linear functional of the standard Poincaré invariant quantization by a singular one. This singular positive linear functional is constructed as mimicking the singular limit of the complex structure of the Poincaré invariant Fock quantization. The resulting symmetry group of such polymer quantization is the subgroup SDiff(ℝ4) which is a subgroup of Diff(ℝ4) formed by spatial volume preserving diffeomorphisms. In consequence, this yields an entirely different irreducible representation of the canonical commutation relations, nonunitary equivalent to the standard Fock representation. We also compared the Poincaré invariant Fock vacuum with the polymer Fourier vacuum.
Sensitivity analysis of physiological factors in space habitat design
NASA Technical Reports Server (NTRS)
Billingham, J.
1982-01-01
The costs incurred by design conservatism in space habitat design are discussed from a structural standpoint, and areas of physiological research into less than earth-normal conditions that offer the greatest potential decrease in habitat construction and operating costs are studied. The established range of human tolerance limits is defined for those physiological conditions which directly affect habitat structural design. These entire ranges or portions thereof are set as habitat design constraints as a function of habitat population and degree of ecological closure. Calculations are performed to determine the structural weight and cost associated with each discrete population size and its selected environmental conditions, on the basis of habitable volume equivalence for four basic habitat configurations: sphere, cylinder with hemispherical ends, torus, and crystal palace.
Valente, João; Vieira, Pedro M; Couto, Carlos; Lima, Carlos S
2018-02-01
Poor brain extraction in Magnetic Resonance Imaging (MRI) has negative consequences in several types of brain post-extraction such as tissue segmentation and related statistical measures or pattern recognition algorithms. Current state of the art algorithms for brain extraction work on weighted T1 and T2, being not adequate for non-whole brain images such as the case of T2*FLASH@7T partial volumes. This paper proposes two new methods that work directly in T2*FLASH@7T partial volumes. The first is an improvement of the semi-automatic threshold-with-morphology approach adapted to incomplete volumes. The second method uses an improved version of a current implementation of the fuzzy c-means algorithm with bias correction for brain segmentation. Under high inhomogeneity conditions the performance of the first method degrades, requiring user intervention which is unacceptable. The second method performed well for all volumes, being entirely automatic. State of the art algorithms for brain extraction are mainly semi-automatic, requiring a correct initialization by the user and knowledge of the software. These methods can't deal with partial volumes and/or need information from atlas which is not available in T2*FLASH@7T. Also, combined volumes suffer from manipulations such as re-sampling which deteriorates significantly voxel intensity structures making segmentation tasks difficult. The proposed method can overcome all these difficulties, reaching good results for brain extraction using only T2*FLASH@7T volumes. The development of this work will lead to an improvement of automatic brain lesions segmentation in T2*FLASH@7T volumes, becoming more important when lesions such as cortical Multiple-Sclerosis need to be detected. Copyright © 2017 Elsevier B.V. All rights reserved.
2015-10-01
cancer is through imaging techniques including ultrasound , computed tomography (CT), and magnetic resonance imaging (MRI) with or without the help...performed at least 8 weeks after transrectal ultrasound -guided sextant biopsy. The entire protocol was ap- proved by the Institutional Review Board...volume of interest (VOI) was localized using three slice-selective radiofrequency (RF) pulses (90°–180°–180°) (Fig. 1). The total time for the
The Coast Artillery Journal. Volume 78, Number 6, November-December 1935
1935-12-01
Byrne, Brig. Gen. John J 157 Campbell, Captain James T 386, 443 Case , Captain Homer 345, 459 CaygiII, Major Harry W 262, 358 Chaffin, Colonel A . D 124...Campbell. Seven Years A -Scorlng .........................•..... By Captain Homer Case . Military English .........•........................... 463 By...to the entire Corps, both officers and enlisted men, my best wishes for a :fllltrrp ~brit)tmat) anb a ~appp ~tb.1 !Jear HARRY LEE STEF.l.F., Major
Air and Space Power Journal. Volume 25, Number 2, Summer 2011
2011-01-01
their entire life cycles. The EIO- LCA results give Air Force leaders a basis for evaluating alternative ways of implementing the ser- vice’s energy...strategy. Background Before presenting and discussing the EIO- LCA results , the article addresses envi- ronmental concerns associated with burning fuel...to the EIO- LCA model results , the GWP for the CBTL fuel was 14 percent less than that for the JP-8 fuel, not considering car- bon capture. In other
European Scientific Notes. Volume 35, Number 7,
1981-07-31
simulated the entire processor down cores, semiconductor PROMs, etc. pack- to gate level on a PDP-11/45 computer, aged on FUROCARDS can be interfaced...approaching retirement were used to generate internal heat age , but DERMO will undoubtedly con- when irradiated. It was found that tinue to be France’s leading...import- parameters , such a doublet will focus ance. it plays an important role not a bundle of rays incident parallel only in mapping and defining the
NASA Technical Reports Server (NTRS)
Martin, T. V.; Mullins, N. E.
1972-01-01
The operating and set-up procedures for the multi-satellite, multi-arc GEODYN- Orbit Determination program are described. All system output is analyzed. The GEODYN Program is the nucleus of the entire GEODYN system. It is a definitive orbit and geodetic parameter estimation program capable of simultaneously processing observations from multiple arcs of multiple satellites. GEODYN has two modes of operation: (1) the data reduction mode and (2) the orbit generation mode.
Parameters, Journal of the US Army War College, Volume 15, Number 4, Winter 1985.
1985-01-01
devices, has built consist entirely of a staff-no legions, just palace its own close-support air force-hundreds of courtesans. armed helicopters...newscasters who announce how many ON BUCKINGHAM Americans are involved in an international crisis AND MILITARY ETHICS because they know you will be...moral outrage when MG Buckingham was very simple and self-evident concept explains why on active duty? Is it ethical to wait until his many of the
1983-07-01
the decomposition reaction (Leider, 1981; Kageyama, 1973; Wolfrom, 1956), 2) Hydrolysis of linkages between glucose units (Urbanski, 1964), 3... dehydration ), 2) Acceleration period (to 50 percent decomposition ), 3) First order reaction rate period. The products of thermal decomposition of...simple mechanism to clean an entire building at once. o Depending on the contaminant, thermal decomposition and or hydrolysis may occur. o May be
The Coast Artillery Journal. Volume 59, Number 2, August 1923
1923-08-01
writers and artists have used it as a device for Joan of Arc. Heraldically the phoenix is always represented as an eagle rising from flames, and in...181) THE BULLETI~ BOARD 185 graphs of two artistic pieces in sterling silver which have just been completed by the Bailey Banks and Biddle Company...the supper hour the gatheriIU! again assembled on the parade ground to "itness a demonstration of cornbin~ gymnastics and calisthenics by the entire
Unstructured 3D Delaunay mesh generation applied to planes, trains and automobiles
NASA Technical Reports Server (NTRS)
Blake, Kenneth R.; Spragle, Gregory S.
1993-01-01
Technical issues associated with domain-tessellation production, including initial boundary node triangulation and volume mesh refinement, are presented for the 'TGrid' 3D Delaunay unstructured grid generation program. The approach employed is noted to be capable of preserving predefined triangular surface facets in the final tessellation. The capabilities of the approach are demonstrated by generating grids about an entire fighter aircraft configuration, a train, and a wind tunnel model of an automobile.
Papers from the Fifth Regional Meeting of the Chicago Linguistic Society, April 18-19, 1969.
ERIC Educational Resources Information Center
Binnick, Robert I., Ed.; And Others
The topics covered in this volume range over the entire field of linguistics. The authors are: A.L. Becker and D.G. Arms, W.R. Cantrall, G. Cohen, D.J. Darden, A. Davison, D. Elliott and others, J.E. Emonds, B. Fraser, G.M. Green, J.T. Heringer, L.R. Horn, L. Kartunnen, G. Lakoff, R. Lakoff, J.M. Lindholm, V.B. Makkai, J.L. Morgan, Y.C. Morin and…
International Standard Payload Rack volume
NASA Technical Reports Server (NTRS)
2001-01-01
Outer dimensions of the International Standard Payload Rack (ISPR) that will be used on the International Space Station (ISS) sets the envelope for scientists designing hardware for experiments in biological and physical sciences aboard ISS. The ISPR includes attachments to ISS utilities (electrical power, heating and cooling, data, fluids, vacuum, etc.) through standoffs that hold the racks in place in the lab modules. Usage will range from facilities that take entire racks to specialized drawers occupying a portion of a rack.
NASA Astrophysics Data System (ADS)
Williams, Kathryn R.
1999-08-01
Since The Journal's inception in 1924, almost every issue has contained at least one article relating to the history of chemistry. But JCE should not be overlooked as a source for social and political history. At no time did the Journal better serve as a mirror of society than during the World War II era. This month's look at the past focusses on volume 19 (1942), which illustrates the response of the entire nation, especially colleges and universities, to the attack on Pearl Harbor.
High throughput on-chip analysis of high-energy charged particle tracks using lensfree imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Wei; Shabbir, Faizan; Gong, Chao
2015-04-13
We demonstrate a high-throughput charged particle analysis platform, which is based on lensfree on-chip microscopy for rapid ion track analysis using allyl diglycol carbonate, i.e., CR-39 plastic polymer as the sensing medium. By adopting a wide-area opto-electronic image sensor together with a source-shifting based pixel super-resolution technique, a large CR-39 sample volume (i.e., 4 cm × 4 cm × 0.1 cm) can be imaged in less than 1 min using a compact lensfree on-chip microscope, which detects partially coherent in-line holograms of the ion tracks recorded within the CR-39 detector. After the image capture, using highly parallelized reconstruction and ion track analysis algorithms running on graphics processingmore » units, we reconstruct and analyze the entire volume of a CR-39 detector within ∼1.5 min. This significant reduction in the entire imaging and ion track analysis time not only increases our throughput but also allows us to perform time-resolved analysis of the etching process to monitor and optimize the growth of ion tracks during etching. This computational lensfree imaging platform can provide a much higher throughput and more cost-effective alternative to traditional lens-based scanning optical microscopes for ion track analysis using CR-39 and other passive high energy particle detectors.« less
Global Scale Solar Disturbances
NASA Astrophysics Data System (ADS)
Title, A. M.; Schrijver, C. J.; DeRosa, M. L.
2013-12-01
The combination of the STEREO and SDO missions have allowed for the first time imagery of the entire Sun. This coupled with the high cadence, broad thermal coverage, and the large dynamic range of the Atmospheric Imaging Assembly on SDO has allowed discovery of impulsive solar disturbances that can significantly affect a hemisphere or more of the solar volume. Such events are often, but not always, associated with M and X class flares. GOES C and even B class flares are also associated with these large scale disturbances. Key to the recognition of the large scale disturbances was the creation of log difference movies. By taking the log of images before differencing events in the corona become much more evident. Because such events cover such a large portion of the solar volume their passage can effect the dynamics of the entire corona as it adjusts to and recovers from their passage. In some cases this may lead to a another flare or filament ejection, but in general direct causal evidence of 'sympathetic' behavior is lacking. However, evidence is accumulating these large scale events create an environment that encourages other solar instabilities to occur. Understanding the source of these events and how the energy that drives them is built up, stored, and suddenly released is critical to understanding the origins of space weather. Example events and comments of their relevance will be presented.
Quantification of the thorax-to-abdomen breathing ratio for breathing motion modeling.
White, Benjamin M; Zhao, Tianyu; Lamb, James; Bradley, Jeffrey D; Low, Daniel A
2013-06-01
The purpose of this study was to develop a methodology to quantitatively measure the thorax-to-abdomen breathing ratio from a 4DCT dataset for breathing motion modeling and breathing motion studies. The thorax-to-abdomen breathing ratio was quantified by measuring the rate of cross-sectional volume increase throughout the thorax and abdomen as a function of tidal volume. Twenty-six 16-slice 4DCT patient datasets were acquired during quiet respiration using a protocol that acquired 25 ciné scans at each couch position. Fifteen datasets included data from the neck through the pelvis. Tidal volume, measured using a spirometer and abdominal pneumatic bellows, was used as breathing-cycle surrogates. The cross-sectional volume encompassed by the skin contour when compared for each CT slice against the tidal volume exhibited a nearly linear relationship. A robust iteratively reweighted least squares regression analysis was used to determine η(i), defined as the amount of cross-sectional volume expansion at each slice i per unit tidal volume. The sum Ση(i) throughout all slices was predicted to be the ratio of the geometric expansion of the lung and the tidal volume; 1.11. The Xiphoid process was selected as the boundary between the thorax and abdomen. The Xiphoid process slice was identified in a scan acquired at mid-inhalation. The imaging protocol had not originally been designed for purposes of measuring the thorax-to-abdomen breathing ratio so the scans did not extend to the anatomy with η(i) = 0. Extrapolation of η(i)-η(i) = 0 was used to include the entire breathing volume. The thorax and abdomen regions were individually analyzed to determine the thorax-to-abdomen breathing ratios. There were 11 image datasets that had been scanned only through the thorax. For these cases, the abdomen breathing component was equal to 1.11 - Ση(i) where the sum was taken throughout the thorax. The average Ση(i) for thorax and abdomen image datasets was found to be 1.20 ± 0.17, close to the expected value of 1.11. The thorax-to-abdomen breathing ratio was 0.32 ± 0.24. The average Ση(i) was 0.26 ± 0.14 in the thorax and 0.93 ± 0.22 in the abdomen. In the scan datasets that encompassed only the thorax, the average Ση(i) was 0.21 ± 0.11. A method to quantify the relationship between abdomen and thoracic breathing was developed and characterized.
Karthick, N K; Kumbharkhane, A C; Joshi, Y S; Mahendraprabu, A; Shanmugam, R; Elangovan, A; Arivazhagan, G
2017-05-05
Dielectric studies using Time Domain Reflectometry method has been carried out on the binary solution of Ethyl acetate (EA) with Chlorobenzene (CBZ) over the entire composition range. Spectroscopic (FTIR and 13 C NMR) signatures of neat EA, CBZ and their equimolar binary solution have also been recorded. The results of the spectroscopic studies favour the presence of (CBZ) CH⋯OC (EA), (EA) methylene CH⋯π electrons (CBZ) and (EA) methyl CH⋯Cl (CBZ) contacts which have been validated using quantum chemical calculations. Dimerization of CBZ has been identified. Presence of β-clusters has been identified in all the solutions. Although EA and CBZ molecules have nearly equal molar volumes, CBZ molecules experience larger hindrance for the rotation than EA molecules. Very small excess dielectric constant (ε E ) values may be correlated with weak heteromolecular forces and/or closed heteromolecular association. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Karthick, N. K.; Kumbharkhane, A. C.; Joshi, Y. S.; Mahendraprabu, A.; Shanmugam, R.; Elangovan, A.; Arivazhagan, G.
2017-05-01
Dielectric studies using Time Domain Reflectometry method has been carried out on the binary solution of Ethyl acetate (EA) with Chlorobenzene (CBZ) over the entire composition range. Spectroscopic (FTIR and 13C NMR) signatures of neat EA, CBZ and their equimolar binary solution have also been recorded. The results of the spectroscopic studies favour the presence of (CBZ) Csbnd H ⋯ Odbnd C (EA), (EA) methylene Csbnd H ⋯ π electrons (CBZ) and (EA) methyl Csbnd H ⋯ Cl (CBZ) contacts which have been validated using quantum chemical calculations. Dimerization of CBZ has been identified. Presence of β-clusters has been identified in all the solutions. Although EA and CBZ molecules have nearly equal molar volumes, CBZ molecules experience larger hindrance for the rotation than EA molecules. Very small excess dielectric constant (εE) values may be correlated with weak heteromolecular forces and/or closed heteromolecular association.
NASA Technical Reports Server (NTRS)
1973-01-01
The traffic analyses and system requirements data generated in the study resulted in the development of two traffic models; the baseline traffic model and the new traffic model. The baseline traffic model provides traceability between the numbers and types of geosynchronous missions considered in the study and the entire spectrum of missions foreseen in the total national space program. The information presented pertaining to the baseline traffic model includes: (1) definition of the baseline traffic model, including identification of specific geosynchronous missions and their payload delivery schedules through 1990; (2) Satellite location criteria, including the resulting distribution of the satellite population; (3) Geosynchronous orbit saturation analyses, including the effects of satellite physical proximity and potential electromagnetic interference; and (4) Platform system requirements analyses, including satellite and mission equipment descriptions, the options and limitations in grouping satellites, and on-orbit servicing criteria (both remotely controlled and man-attended).
NASA Astrophysics Data System (ADS)
Kianpour, E.; Nor Azwadi, C. S.; Golshokouh, I.
2013-12-01
We studied the effects of cylindrical and row trenched cooling holes with alignment angle of 0° at BR=3.18 on the film cooling performance near the endwall surface of a combustor simulator. In this research, a three-dimensional presentation of gas turbine engine was simulated and analyzed with a commercial finite volume package FLUENT 6.2.26 to gain fundamental data. The current study has been performed with Reynolds-averaged Navier-Stokes turbulence model (RANS) on internal cooling passages. This combustor simulator combined the interaction of two rows of dilution jets, which were staggered in the stream wise direction and aligned in the span wise direction. The entire findings of the study declared that with using the row trenched holes near the enwall surface; film cooling effectiveness is doubled compared to the cooling performance of baseline case.
O’Dwyer, Laurence; Tanner, Colby; van Dongen, Eelco V.; Greven, Corina U.; Bralten, Janita; Zwiers, Marcel P.; Franke, Barbara; Heslenfeld, Dirk; Oosterlaan, Jaap; Hoekstra, Pieter J.; Hartman, Catharina A.; Groen, Wouter; Rommelse, Nanda; Buitelaar, Jan K.
2016-01-01
Autism spectrum disorder (ASD) symptoms frequently occur in individuals with attention-deficit/hyperactivity disorder (ADHD). While there is evidence that both ADHD and ASD have differential structural brain correlates, knowledge of the structural brain profile of individuals with ADHD with raised ASD symptoms is limited. The presence of ASD-like symptoms was measured by the Children's Social Behavior Questionnaire (CSBQ) in a sample of typically developing controls (n = 154), participants with ADHD (n = 239), and their unaffected siblings (n = 144) between the ages of 8 and 29. Structural magnetic resonance imaging (MRI) correlates of ASD ratings were analysed by studying the relationship between ASD ratings and grey matter volumes using mixed effects models which controlled for ADHD symptom count and total brain volume. ASD ratings were significantly elevated in participants with ADHD relative to controls and unaffected siblings. For the entire group (participants with ADHD, unaffected siblings and TD controls), mixed effect models revealed that the left caudate nucleus volume was negatively correlated with ASD ratings (t = 2.83; P = 0.005). The current findings are consistent with the role of the caudate nucleus in executive function, including the selection of goals based on the evaluation of action outcomes and the use of social reward to update reward representations. There is a specific volumetric profile associated with subclinical ASD-like symptoms in participants with ADHD, unaffected siblings and controls with the caudate nucleus and globus pallidus being of critical importance in predicting the level of ASD-like symptoms in all three groups. PMID:27806078
Gilliam, Mary; Forbes, Erika E; Gianaros, Peter J; Erickson, Kirk I; Brennan, Lauretta M; Shaw, Daniel S
2015-10-01
There is abundant evidence that offspring of depressed mothers are at increased risk for persistent behavior problems related to emotion regulation, but the mechanisms by which offspring incur this risk are not entirely clear. Early adverse caregiving experiences have been associated with structural alterations in the amygdala and hippocampus, which parallel findings of cortical regions altered in adults with behavior problems related to emotion regulation. This study examined whether exposure to maternal depression during childhood might predict increased aggression and/or depression in early adulthood, and whether offspring amygdala:hippocampal volume ratio might mediate this relationship. Participants were 258 mothers and sons at socioeconomic risk for behavior problems. Sons' trajectories of exposure to maternal depression were generated from eight reports collected prospectively from offspring ages 18 months to 10 years. Offspring brain structure, aggression, and depression were assessed at age 20 (n = 170). Persistent, moderately high trajectories of maternal depression during childhood predicted increased aggression in adult offspring. In contrast, stable and very elevated trajectories of maternal depression during childhood predicted depression in adult offspring. Increased amygdala: hippocampal volume ratios at age 20 were significantly associated with concurrently increased aggression, but not depression, in adult offspring. Offspring amygdala: hippocampal volume ratio mediated the relationship found between trajectories of moderately elevated maternal depression during childhood and aggression in adult offspring. Alterations in the relative size of brain structures implicated in emotion regulation may be one mechanism by which offspring of depressed mothers incur increased risk for the development of aggression. © 2014 Association for Child and Adolescent Mental Health.
Chest wall mechanics in sustained microgravity
NASA Technical Reports Server (NTRS)
Wantier, M.; Estenne, M.; Verbanck, S.; Prisk, G. K.; Paiva, M.; West, J. B. (Principal Investigator)
1998-01-01
We assessed the effects of sustained weightlessness on chest wall mechanics in five astronauts who were studied before, during, and after the 10-day Spacelab D-2 mission (n = 3) and the 180-day Euromir-95 mission (n = 2). We measured flow and pressure at the mouth and rib cage and abdominal volumes during resting breathing and during a relaxation maneuver from midinspiratory capacity to functional residual capacity. Microgravity produced marked and consistent changes (Delta) in the contribution of the abdomen to tidal volume [DeltaVab/(DeltaVab + DeltaVrc), where Vab is abdominal volume and Vrc is rib cage volume], which increased from 30.7 +/- 3. 5 (SE)% at 1 G head-to-foot acceleration to 58.3 +/- 5.7% at 0 G head-to-foot acceleration (P < 0.005). Values of DeltaVab/(DeltaVab + DeltaVrc) did not change significantly during the 180 days of the Euromir mission, but in the two subjects DeltaVab/(DeltaVab + DeltaVrc) was greater on postflight day 1 than on subsequent postflight days or preflight. In the two subjects who produced satisfactory relaxation maneuvers, the slope of the Konno-Mead plot decreased in microgravity; this decrease was entirely accounted for by an increase in abdominal compliance because rib cage compliance did not change. These alterations are similar to those previously reported during short periods of weightlessness inside aircrafts flying parabolic trajectories. They are also qualitatively similar to those observed on going from upright to supine posture; however, in contrast to microgravity, such postural change reduces rib cage compliance.
Preliminary Testing of a Compact, Bone-Attached Robot for Otologic Surgery
Dillon, Neal P.; Balachandran, Ramya; dit Falisse, Antoine Motte; Wanna, George B.; Labadie, Robert F.; Withrow, Thomas J.; Fitzpatrick, J. Michael; Webster, Robert J.
2014-01-01
Otologic surgery often involves a mastoidectomy procedure, in which part of the temporal bone is milled away in order to visualize critical structures embedded in the bone and safely access the middle and inner ear. We propose to automate this portion of the surgery using a compact, bone-attached milling robot. A high level of accuracy is required to avoid damage to vital anatomy along the surgical path, most notably the facial nerve, making this procedure well-suited for robotic intervention. In this study, several of the design considerations are discussed and a robot design and prototype are presented. The prototype is a 4 degrees-of-freedom robot similar to a four-axis milling machine that mounts to the patient’s skull. A positioning frame, containing fiducial markers and attachment points for the robot, is rigidly attached to the skull of the patient, and a CT scan is acquired. The target bone volume is manually segmented in the CT by the surgeon and automatically converted to a milling path and robot trajectory. The robot is then attached to the positioning frame and is used to drill the desired volume. The accuracy of the entire system (image processing, planning, robot) was evaluated at several critical locations within or near the target bone volume with a mean free space accuracy result of 0.50 mm or less at all points. A milling test in a phantom material was then performed to evaluate the surgical workflow. The resulting milled volume did not violate any critical structures. PMID:25477726
Trends in Radical Prostatectomy: Centralization, Robotics, and Access to Urologic Cancer Care
Stitzenberg, Karyn B.; Wong, Yu-Ning; Nielsen, Matthew E.; Egleston, Brian L.; Uzzo, Robert G.
2011-01-01
Background Robotic surgery has been widely adopted for radical prostatectomy. We hypothesize that this change is rapidly shifting procedures away from hospitals that do not offer robotics and consequently increasing patient travel. Methods A population-based observational study of all prostatectomies for cancer in NY, NJ, and PA from 2000–2009 was performed using hospital discharge data. Hospital procedure volume was defined as the number of prostatectomies performed for cancer in a given year. Straight-line travel distance to treating hospital was calculated for each case. Hospitals were contacted to determine year of acquisition of first robot. Results From 2000–2009, the total number of prostatectomies performed annually increased substantially. The increase occurred almost entirely at the very high volume centers (≥106 prostatectomies/year). The number of hospitals performing prostatectomy fell 37% from 2000–2009. By 2009, the 9% (21/244) of hospitals that had very high volume performed 57% of all prostatectomies, and the 35% (86/244) of hospitals with a robot performed 85% of all prostatectomies. Median travel increased 54% from 2000–2009, p<0.001. The proportion of patients traveling ≥15 miles increased from 24% to 40%, p<0.001. Conclusions Over the past decade, the number of radical prostatectomies performed has risen substantially. These procedures have been increasingly centralized at high volume centers, leading to longer patient travel distances. Few prostatectomies are now performed at hospitals that do not offer robotic surgery. Future work should focus on the impact of these trends on cancer control, functional outcomes, access to care and cost. PMID:21717436
O'Dwyer, Laurence; Tanner, Colby; van Dongen, Eelco V; Greven, Corina U; Bralten, Janita; Zwiers, Marcel P; Franke, Barbara; Heslenfeld, Dirk; Oosterlaan, Jaap; Hoekstra, Pieter J; Hartman, Catharina A; Groen, Wouter; Rommelse, Nanda; Buitelaar, Jan K
2016-01-01
Autism spectrum disorder (ASD) symptoms frequently occur in individuals with attention-deficit/hyperactivity disorder (ADHD). While there is evidence that both ADHD and ASD have differential structural brain correlates, knowledge of the structural brain profile of individuals with ADHD with raised ASD symptoms is limited. The presence of ASD-like symptoms was measured by the Children's Social Behavior Questionnaire (CSBQ) in a sample of typically developing controls (n = 154), participants with ADHD (n = 239), and their unaffected siblings (n = 144) between the ages of 8 and 29. Structural magnetic resonance imaging (MRI) correlates of ASD ratings were analysed by studying the relationship between ASD ratings and grey matter volumes using mixed effects models which controlled for ADHD symptom count and total brain volume. ASD ratings were significantly elevated in participants with ADHD relative to controls and unaffected siblings. For the entire group (participants with ADHD, unaffected siblings and TD controls), mixed effect models revealed that the left caudate nucleus volume was negatively correlated with ASD ratings (t = 2.83; P = 0.005). The current findings are consistent with the role of the caudate nucleus in executive function, including the selection of goals based on the evaluation of action outcomes and the use of social reward to update reward representations. There is a specific volumetric profile associated with subclinical ASD-like symptoms in participants with ADHD, unaffected siblings and controls with the caudate nucleus and globus pallidus being of critical importance in predicting the level of ASD-like symptoms in all three groups.
A weighted belief-propagation algorithm for estimating volume-related properties of random polytopes
NASA Astrophysics Data System (ADS)
Font-Clos, Francesc; Massucci, Francesco Alessandro; Pérez Castillo, Isaac
2012-11-01
In this work we introduce a novel weighted message-passing algorithm based on the cavity method for estimating volume-related properties of random polytopes, properties which are relevant in various research fields ranging from metabolic networks, to neural networks, to compressed sensing. We propose, as opposed to adopting the usual approach consisting in approximating the real-valued cavity marginal distributions by a few parameters, using an algorithm to faithfully represent the entire marginal distribution. We explain various alternatives for implementing the algorithm and benchmarking the theoretical findings by showing concrete applications to random polytopes. The results obtained with our approach are found to be in very good agreement with the estimates produced by the Hit-and-Run algorithm, known to produce uniform sampling.
Suh, J Y; Shim, Woo H; Cho, Gyunggoo; Fan, Xiang; Kwon, Seon J; Kim, Jeong K; Dai, George; Wang, Xiaoying; Kim, Young R
2015-01-01
Vasoreactivity to hypercapnia has been used for assessing cerebrovascular tone and control altered by ischemic stroke. Despite the high prognostic potential, traits of hypercapnia-induced hemodynamic changes have not been fully characterized in relation with baseline vascular states and brain tissue damage. To monitor cerebrovascular responses, T2- and T2*-weighted magnetic resonance imaging (MRI) images were acquired alternatively using spin- and gradient-echo echo plannar imaging (GESE EPI) sequence with 5% CO2 gas inhalation in normal (n=5) and acute stroke rats (n=10). Dynamic relative changes in cerebrovascular volume (CBV), microvascular volume (MVV), and vascular size index (VSI) were assessed from regions of interest (ROIs) delineated by the percent decrease of apparent diffusion coefficient (ADC). The baseline CBV was not affected by middle cerebral artery occlusion (MCAO) whereas the baseline MVV in ischemic areas was significantly lower than that in the rest of the brain and correlated with ADC. Vasoreactivity to hypercapnic challenge was considerably attenuated in the entire ipsilesional hemisphere including normal ADC regions, in which unsolicited, spreading depression-associated increases of CBV and MVV were observed. The lesion-dependent inhomogeneity in baseline MVV indicates the effective perfusion reserve for accurately delineating the true ischemic damage while the cascade of neuronal depolarization is probably responsible for the hemispherically lateralized changes in overall neurovascular physiology. PMID:25690471
Dynamic Bioreactor Culture of High Volume Engineered Bone Tissue
Nguyen, Bao-Ngoc B.; Ko, Henry; Moriarty, Rebecca A.; Etheridge, Julie M.
2016-01-01
Within the field of tissue engineering and regenerative medicine, the fabrication of tissue grafts of any significant size—much less a whole organ or tissue—remains a major challenge. Currently, tissue-engineered constructs cultured in vitro have been restrained in size primarily due to the diffusion limit of oxygen and nutrients to the center of these grafts. Previously, we developed a novel tubular perfusion system (TPS) bioreactor, which allows the dynamic culture of bead-encapsulated cells and increases the supply of nutrients to the entire cell population. More interestingly, the versatility of TPS bioreactor allows a large range of engineered tissue volumes to be cultured, including large bone grafts. In this study, we utilized alginate-encapsulated human mesenchymal stem cells for the culture of a tissue-engineered bone construct in the size and shape of the superior half of an adult human femur (∼200 cm3), a 20-fold increase over previously reported volumes of in vitro engineered bone grafts. Dynamic culture in TPS bioreactor not only resulted in high cell viability throughout the femur graft, but also showed early signs of stem cell differentiation through increased expression of osteogenic genes and proteins, consistent with our previous models of smaller bone constructs. This first foray into full-scale bone engineering provides the foundation for future clinical applications of bioengineered bone grafts. PMID:26653703
NASA Technical Reports Server (NTRS)
Bauer, F. H.; Moreau, M. C.; Dahle-Melsaether, M. E.; Petrofski, W. P.; Stanton, B. J.; Thomason, S.; Harris, G. A.; Sena, R. P.; Temple, L. Parker, III
2006-01-01
Prior to the advent of artificial satellites, the concept of navigating in space and the desire to understand and validate the laws of planetary and satellite motion dates back centuries. At the initiation of orbital flight in 1957, space navigation was dominated by inertial and groundbased tracking methods, underpinned by the laws of planetary motion. It was early in the 1980s that GPS was first explored as a system useful for refining the position, velocity, and timing (PVT) of other spacecraft equipped with GPS receivers. As a result, an entirely new GPS utility was developed beyond its original purpose of providing PVT services for land, maritime, and air applications. Spacecraft both above and below the GPS constellation now receive the GPS signals, including the signals that spill over the limb of the Earth. The use of radionavigation satellite services for space navigation in High Earth Orbits is in fact a capability unique to GPS. Support to GPS space applications is being studied and planned as an important improvement to GPS. This paper discusses the formalization of PVT services in space as part of an overall GPS improvement effort. It describes the GPS Space Service Volume (SSV) and compares it to the Terrestrial Service Volume (TSV). It also discusses SSV coverage with the current GPS constellation, coverage characteristics as a function of altitude, expected power levels, and coverage figures of merit.
Effect of initial conditions on combustion generated loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tieszen, S.R.
1991-01-01
This analytical study examines the effect of initial thermodynamic conditions on the loads generated by the combustion of homogeneous hydrogen-air-steam mixtures. The effect of initial temperature, pressure, hydrogen concentration, and steam concentration is evaluated for two cases, (1) constant volume and (2) constant initial pressure. For each case, the Adiabatic, Isochoric, Complete Combustion (AICC), Chapman-Jouguet (CJ), and normally reflected CJ pressures are calculated for a range of hydrogen and steam concentrations representative of the entire flammable regime. For detonation loads, pressure profiles and time-histories are also evaluated in one-dimensional Cartesian geometry. The results show that to a first approximation, themore » AICC and CJ pressures are directly proportional to the initial density. Increasing the hydrogen concentration up to stoichiometric concentrations significantly increases the AICC, CJ, and reflected CJ pressures. For the constant volume case, the AICC, CJ, and reflected CJ pressures increase with increasing hydrogen concentration on the rich side of stoichiometric concentrations. For the constant initial pressure case, the AICC, CJ and reflected CJ pressures decrease with increasing hydrogen concentration on the rich side of stoichiometric values. The addition of steam decreases the AICC, CJ and reflected CJ pressures for the constant initial pressure case, but increases them for the constant volume case. For detonations, the pressure time-histories can be normalized with the AICC pressure and the reverberation time for Cartesian geometry. 35 refs., 16 figs.« less
Suh, J Y; Shim, Woo H; Cho, Gyunggoo; Fan, Xiang; Kwon, Seon J; Kim, Jeong K; Dai, George; Wang, Xiaoying; Kim, Young R
2015-06-01
Vasoreactivity to hypercapnia has been used for assessing cerebrovascular tone and control altered by ischemic stroke. Despite the high prognostic potential, traits of hypercapnia-induced hemodynamic changes have not been fully characterized in relation with baseline vascular states and brain tissue damage. To monitor cerebrovascular responses, T2- and T2*-weighted magnetic resonance imaging (MRI) images were acquired alternatively using spin- and gradient-echo echo plannar imaging (GESE EPI) sequence with 5% CO2 gas inhalation in normal (n=5) and acute stroke rats (n=10). Dynamic relative changes in cerebrovascular volume (CBV), microvascular volume (MVV), and vascular size index (VSI) were assessed from regions of interest (ROIs) delineated by the percent decrease of apparent diffusion coefficient (ADC). The baseline CBV was not affected by middle cerebral artery occlusion (MCAO) whereas the baseline MVV in ischemic areas was significantly lower than that in the rest of the brain and correlated with ADC. Vasoreactivity to hypercapnic challenge was considerably attenuated in the entire ipsilesional hemisphere including normal ADC regions, in which unsolicited, spreading depression-associated increases of CBV and MVV were observed. The lesion-dependent inhomogeneity in baseline MVV indicates the effective perfusion reserve for accurately delineating the true ischemic damage while the cascade of neuronal depolarization is probably responsible for the hemispherically lateralized changes in overall neurovascular physiology.
Multiple-stripe lithiation mechanism of individual SnO2 nanowires in a flooding geometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong, Li; Liu, Xiao H.; Wang, G. F.
2011-06-17
The atomic scale lithiation mechanism of individual SnO2 nanowires in a flooding geometry with the entire wires being immersed in the electrolyte was revealed by in-situ transmission electron microscopy. The lithiation initiated multiple stripes with width of a few nanometer parallel to {020} planes transversing the entire wires, serving as multiple reaction fronts for late stage of lithiation. Inside the stripes, we identified high density of dislocations and enlarged inter-planar spacing, which provide effective path for lithium ion transport. The density of the stripes increased with further lithiation, and eventually they merged with one another, causing a large enlongation andmore » volume expansion and the crystalline to amorphous phase transformation. This multiple stripes and multiple reaction fronts lithiation mechanism is unexpected and differs completely from the expected core-shell lithiation mechanism.« less
Honeywell's Compact, Wide-angle Uv-visible Imaging Sensor
NASA Technical Reports Server (NTRS)
Pledger, D.; Billing-Ross, J.
1993-01-01
Honeywell is currently developing the Earth Reference Attitude Determination System (ERADS). ERADS determines attitude by imaging the entire Earth's limb and a ring of the adjacent star field in the 2800-3000 A band of the ultraviolet. This is achieved through the use of a highly nonconventional optical system, an intensifier tube, and a mega-element CCD array. The optics image a 30 degree region in the center of the field, and an outer region typically from 128 to 148 degrees, which can be adjusted up to 180 degrees. Because of the design employed, the illumination at the outer edge of the field is only some 15 percent below that at the center, in contrast to the drastic rolloffs encountered in conventional wide-angle sensors. The outer diameter of the sensor is only 3 in; the volume and weight of the entire system, including processor, are 1000 cc and 6 kg, respectively.
Micro-patterning of resin-bonded NdFeB magnet for a fully integrated electromagnetic actuator
NASA Astrophysics Data System (ADS)
Tao, Kai; Wu, Jin; Kottapalli, Ajay Giri Prakash; Chen, Di; Yang, Zhuoqing; Ding, Guifu; Lye, Sun Woh; Miao, Jianmin
2017-12-01
This paper reports a fully-integrated, batch-fabricated electromagnetic actuator which features micro-patterned NdFeB magnets. The entire actuator is fabricated through MEMS-compatible laminated surface micromachining technology, eliminating the requirement for further component assembly processes. The fabrication strategy allowed the entire volume of the actuator to be reduced to a small size of 2.5 × 2.5 × 2 mm3, which is one of the smallest NdFeB-based electromagnetic actuators demonstrated to date. The magnetic properties of NdFeB thin films are further investigated and optimized using different types of lithographically-defined micromolds. By altering the direction of the input current, actuating displacements of approximately ±10 μm are achieved during both the attraction and the repulsion operations. This work demonstrates the viability and compatibility of using polymer-bonded magnets for magnetic MEMS applications.
Neutron Characterization of Encapsulated ATF-1/LANL-1 Mockup Fuel Capsules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vogel, Sven C.; Borges, Nicholas Paul; Losko, Adrian Simon
Twenty pellets of mock-up accident tolerant fuels UN-U3Si5 were produced at LANL and loaded in two rodlet/capsule assemblies. Tomographic imaging and diffraction measurements were performed to characterize these samples at the Flight-Path 5 and HIPPO beam lines at LANSCE/LANL between November 2016 and January 2017 as well as in August 2017. The entire ~10 cm long, ~1 cm diameter fuel volume could be characterized, however due to time constraints only 2 mm slices in 4mm increments were characterized with neutron diffraction and a 28mm subset of the entire sample was characterized with energy-resolved neutron imaging. The double encapsulation of themore » fuel into two steel containers does not pose a problem for the neutron analysis and the methods could be applied to enriched as well irradiated fuels.« less
Integrated fluorescence analysis system
Buican, Tudor N.; Yoshida, Thomas M.
1992-01-01
An integrated fluorescence analysis system enables a component part of a sample to be virtually sorted within a sample volume after a spectrum of the component part has been identified from a fluorescence spectrum of the entire sample in a flow cytometer. Birefringent optics enables the entire spectrum to be resolved into a set of numbers representing the intensity of spectral components of the spectrum. One or more spectral components are selected to program a scanning laser microscope, preferably a confocal microscope, whereby the spectrum from individual pixels or voxels in the sample can be compared. Individual pixels or voxels containing the selected spectral components are identified and an image may be formed to show the morphology of the sample with respect to only those components having the selected spectral components. There is no need for any physical sorting of the sample components to obtain the morphological information.
Lamiman, Kelly; Wong, Kenneth K; Tamrazi, Benita; Nosrati, Jason D; Olch, Arthur; Chang, Eric L; Kiehna, Erin N
2016-12-01
OBJECTIVE When complete resection of craniopharyngioma is not achievable or the sequelae are prohibitive, limited surgery and radiation therapy have demonstrated excellent local disease control while minimizing treatment-related sequelae. When residual tissue exists, there is a propensity for further cyst development and expansion during and after radiation therapy. This can result in obstructive hydrocephalus, visual changes, and/or clinical decline. The authors present a quantitative analysis of cyst expansion during and after radiotherapy and examine how it affected subsequent management. METHODS The authors performed an institutional review board-approved retrospective study of patients with histologically confirmed craniopharyngioma treated between 2000 and 2015 with surgery and intensity-modulated radiation therapy (IMRT) at a single institution. Volumetric measurements of cyst contours were generated by radiation oncology treatment planning software postoperatively, during IMRT, and up to 12 months after IMRT. Patient, tumor, and treatment-related variables were collected until the last known follow-up and were analyzed. RESULTS Twenty-seven patients underwent surgery and IMRT. The median total radiation dose was 54 Gy. Of the 27 patients, 11 patients (40.7%) demonstrated cyst expansions within 1 year of IMRT. Of note, all tumors with cyst expansion were radiographically Puget Grade 2. Maximal cyst expansion peaked at 4.27 months following radiation therapy, with a median volume growth of 4.1 cm 3 (mean 9.61 cm 3 ) above the postoperative cyst volume. Eight patients experienced spontaneous cyst regression without therapeutic intervention. Three patients experienced MRI-confirmed cyst enlargement during IMRT, all of whom required adaptive planning to ensure adequate coverage of the entire tumor volume. Two of these 3 patients required ventriculoperitoneal shunt placement and additional intervention. One underwent additional resection, and the other had placement of an intracystic catheter for aspiration and delivery of intracystic interferon within 12 months of completing IMRT. All 3 patients now have stable disease. CONCLUSIONS Craniopharyngioma cyst expansion occurred in approximately 40% of the patients during or after radiotherapy. In the majority of patients, cyst expansion was a self-limiting process and did not confer a worse outcome. During radiotherapy, cyst expansion may be apparent on image-guided radiation therapy. Adaptive IMRT planning may be required to ensure that the intended IMRT dose covers the entire tumor and cyst volume. The sequelae of cyst expansion include progressive hydrocephalus, which may be treated with a shunt. For patients with solitary cyst expansion, cyst aspiration and/or intracystic interferon may result in disease control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fave, Xenia, E-mail: xjfave@mdanderson.org; Fried, David; Mackin, Dennis
Purpose: Increasing evidence suggests radiomics features extracted from computed tomography (CT) images may be useful in prognostic models for patients with nonsmall cell lung cancer (NSCLC). This study was designed to determine whether such features can be reproducibly obtained from cone-beam CT (CBCT) images taken using medical Linac onboard-imaging systems in order to track them through treatment. Methods: Test-retest CBCT images of ten patients previously enrolled in a clinical trial were retrospectively obtained and used to determine the concordance correlation coefficient (CCC) for 68 different texture features. The volume dependence of each feature was also measured using the Spearman rankmore » correlation coefficient. Features with a high reproducibility (CCC > 0.9) that were not due to volume dependence in the patient test-retest set were further examined for their sensitivity to differences in imaging protocol, level of scatter, and amount of motion by using two phantoms. The first phantom was a texture phantom composed of rectangular cartridges to represent different textures. Features were measured from two cartridges, shredded rubber and dense cork, in this study. The texture phantom was scanned with 19 different CBCT imagers to establish the features’ interscanner variability. The effect of scatter on these features was studied by surrounding the same texture phantom with scattering material (rice and solid water). The effect of respiratory motion on these features was studied using a dynamic-motion thoracic phantom and a specially designed tumor texture insert of the shredded rubber material. The differences between scans acquired with different Linacs and protocols, varying amounts of scatter, and with different levels of motion were compared to the mean intrapatient difference from the test-retest image set. Results: Of the original 68 features, 37 had a CCC >0.9 that was not due to volume dependence. When the Linac manufacturer and imaging protocol were kept consistent, 4–13 of these 37 features passed our criteria for reproducibility more than 50% of the time, depending on the manufacturer-protocol combination. Almost all of the features changed substantially when scatter material was added around the phantom. For the dense cork, 23 features passed in the thoracic scans and 11 features passed in the head scans when the differences between one and two layers of scatter were compared. Using the same test for the shredded rubber, five features passed the thoracic scans and eight features passed the head scans. Motion substantially impacted the reproducibility of the features. With 4 mm of motion, 12 features from the entire volume and 14 features from the center slice measurements were reproducible. With 6–8 mm of motion, three features (Laplacian of Gaussian filtered kurtosis, gray-level nonuniformity, and entropy), from the entire volume and seven features (coarseness, high gray-level run emphasis, gray-level nonuniformity, sum-average, information measure correlation, scaled mean, and entropy) from the center-slice measurements were considered reproducible. Conclusions: Some radiomics features are robust to the noise and poor image quality of CBCT images when the imaging protocol is consistent, relative changes in the features are used, and patients are limited to those with less than 1 cm of motion.« less
Miyazaki, Yuta; Song, Jae W.; Takahashi, Emi
2016-01-01
The radial and tangential neural migration pathways are two major neuronal migration streams in humans that are critical during corticogenesis. Corticogenesis is a complex process of neuronal proliferation that is followed by neuronal migration and the formation of axonal connections. Existing histological assessments of these two neuronal migration pathways have limitations inherent to microscopic studies and are confined to small anatomic regions of interest (ROIs). Thus, little evidence is available about their three-dimensional (3-D) fiber pathways and development throughout the entire brain. In this study, we imaged and analyzed radial and tangential migration pathways in the whole human brain using high-angular resolution diffusion MR imaging (HARDI) tractography. We imaged ten fixed, postmortem fetal (17 gestational weeks (GW), 18 GW, 19 GW, three 20 GW, three 21 GW and 22 GW) and eight in vivo newborn (two 30 GW, 34 GW, 35 GW and four 40 GW) brains with no neurological/pathological conditions. We statistically compared the volume of the left and right radial and tangential migration pathways, and the volume of the radial migration pathways of the anterior and posterior regions of the brain. In specimens 22 GW or younger, the volume of radial migration pathways of the left hemisphere was significantly larger than that of the right hemisphere. The volume of posterior radial migration pathways was also larger when compared to the anterior pathways in specimens 22 GW or younger. In contrast, no significant differences were observed in the radial migration pathways of brains older than 22 GW. Moreover, our study did not identify any significant differences in volumetric laterality in the tangential migration pathways. These results suggest that these two neuronal migration pathways develop and regress differently, and radial neuronal migration varies regionally based on hemispheric and anterior-posterior laterality, potentially explaining regional differences in the amount of excitatory neurons that migrate along the radial scaffold. PMID:26834572
Fokker-Planck description for the queue dynamics of large tick stocks.
Garèche, A; Disdier, G; Kockelkoren, J; Bouchaud, J-P
2013-09-01
Motivated by empirical data, we develop a statistical description of the queue dynamics for large tick assets based on a two-dimensional Fokker-Planck (diffusion) equation. Our description explicitly includes state dependence, i.e., the fact that the drift and diffusion depend on the volume present on both sides of the spread. "Jump" events, corresponding to sudden changes of the best limit price, must also be included as birth-death terms in the Fokker-Planck equation. All quantities involved in the equation can be calibrated using high-frequency data on the best quotes. One of our central findings is that the dynamical process is approximately scale invariant, i.e., the only relevant variable is the ratio of the current volume in the queue to its average value. While the latter shows intraday seasonalities and strong variability across stocks and time periods, the dynamics of the rescaled volumes is universal. In terms of rescaled volumes, we found that the drift has a complex two-dimensional structure, which is a sum of a gradient contribution and a rotational contribution, both stable across stocks and time. This drift term is entirely responsible for the dynamical correlations between the ask queue and the bid queue.
Fokker-Planck description for the queue dynamics of large tick stocks
NASA Astrophysics Data System (ADS)
Garèche, A.; Disdier, G.; Kockelkoren, J.; Bouchaud, J.-P.
2013-09-01
Motivated by empirical data, we develop a statistical description of the queue dynamics for large tick assets based on a two-dimensional Fokker-Planck (diffusion) equation. Our description explicitly includes state dependence, i.e., the fact that the drift and diffusion depend on the volume present on both sides of the spread. “Jump” events, corresponding to sudden changes of the best limit price, must also be included as birth-death terms in the Fokker-Planck equation. All quantities involved in the equation can be calibrated using high-frequency data on the best quotes. One of our central findings is that the dynamical process is approximately scale invariant, i.e., the only relevant variable is the ratio of the current volume in the queue to its average value. While the latter shows intraday seasonalities and strong variability across stocks and time periods, the dynamics of the rescaled volumes is universal. In terms of rescaled volumes, we found that the drift has a complex two-dimensional structure, which is a sum of a gradient contribution and a rotational contribution, both stable across stocks and time. This drift term is entirely responsible for the dynamical correlations between the ask queue and the bid queue.
High Performance GPU-Based Fourier Volume Rendering.
Abdellah, Marwan; Eldeib, Ayman; Sharawi, Amr
2015-01-01
Fourier volume rendering (FVR) is a significant visualization technique that has been used widely in digital radiography. As a result of its (N (2)logN) time complexity, it provides a faster alternative to spatial domain volume rendering algorithms that are (N (3)) computationally complex. Relying on the Fourier projection-slice theorem, this technique operates on the spectral representation of a 3D volume instead of processing its spatial representation to generate attenuation-only projections that look like X-ray radiographs. Due to the rapid evolution of its underlying architecture, the graphics processing unit (GPU) became an attractive competent platform that can deliver giant computational raw power compared to the central processing unit (CPU) on a per-dollar-basis. The introduction of the compute unified device architecture (CUDA) technology enables embarrassingly-parallel algorithms to run efficiently on CUDA-capable GPU architectures. In this work, a high performance GPU-accelerated implementation of the FVR pipeline on CUDA-enabled GPUs is presented. This proposed implementation can achieve a speed-up of 117x compared to a single-threaded hybrid implementation that uses the CPU and GPU together by taking advantage of executing the rendering pipeline entirely on recent GPU architectures.
A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol.
Carnes, Greg; Gaede, Stewart; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim
2009-04-07
Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy chaining' all couch positions using the selected images until an entire 3D volume was produced. The algorithm produced 16 phase volumes to complete a 4D-CT dataset. Additional 4D-CT datasets were also produced using external marker amplitude and phase angle sorting methods. The image quality of the volumes produced by the different methods was quantified by calculating the mean difference of the sorted overlapping slices from adjacent couch positions. The NCC sorted images showed a significant decrease in the mean difference (p < 0.01) for the five patients.
Glocker, Ben; Paragios, Nikos; Komodakis, Nikos; Tziritas, Georgios; Navab, Nassir
2007-01-01
In this paper we propose a novel non-rigid volume registration based on discrete labeling and linear programming. The proposed framework reformulates registration as a minimal path extraction in a weighted graph. The space of solutions is represented using a set of a labels which are assigned to predefined displacements. The graph topology corresponds to a superimposed regular grid onto the volume. Links between neighborhood control points introduce smoothness, while links between the graph nodes and the labels (end-nodes) measure the cost induced to the objective function through the selection of a particular deformation for a given control point once projected to the entire volume domain, Higher order polynomials are used to express the volume deformation from the ones of the control points. Efficient linear programming that can guarantee the optimal solution up to (a user-defined) bound is considered to recover the optimal registration parameters. Therefore, the method is gradient free, can encode various similarity metrics (simple changes on the graph construction), can guarantee a globally sub-optimal solution and is computational tractable. Experimental validation using simulated data with known deformation, as well as manually segmented data demonstrate the extreme potentials of our approach.
Postmortem structural studies of the thalamus in schizophrenia
Dorph-Petersen, Karl-Anton; Lewis, David A.
2017-01-01
In this review, we seek to answer the following question: Do findings in the current literature support the idea that thalamo-cortical dysfunction in schizophrenia is due to structural abnormalities in the thalamus? We base our review on the existing literature of design-unbiased stereological studies of the postmortem thalamus from subjects with schizophrenia. Thus, all reported results are based upon the use of unbiased principles of sampling to determine volume and/or total cell numbers of thalamus or its constituent nuclei. We found 28 such papers covering 26 studies. In a series of tables we list all positive and negative findings from the total thalamus, the mediodorsal, pulvinar and anterior nuclei, as well as less frequently studied thalamic regions. Only four studies examined the entire thalamus and the results were inconsistent. We found largely consistent evidence for structural changes (reduced volume and cell numbers) in the pulvinar located in the posterior thalamus. In contrast, findings in the mediodorsal thalamic nucleus are inconsistent, with the largest and most recent studies generally failing to support earlier reports of a lower number of neurons in schizophrenia. Thus, the current findings of stereological studies of the thalamus in schizophrenia support the idea that thalamo-cortical dysfunction in schizophrenia might be attributable, at least in part, to structural alterations in the pulvinar that could impair thalamic inputs to higher order cortical association areas in the frontal and parietal lobes. However, more studies are needed before robust conclusions can be drawn. PMID:27567291
Geologic studies in Alaska by the U.S. Geological Survey, 1990
Bradley, Dwight C.; Ford, Arthur B.
1992-01-01
This collection of papers continues the annual series of U.S. Geological Survey (USGS) reports on geologic investigations in Alaska. From 1975 through 1988, the series was published as USGS circulars. The first of these appeared under the title "The United States Geological Survey in Alaska: Accomplishments during 1975," and the series continued to the last annual circular entitled "Geologic studies in Alaska by the U.S. Geological Survey during 1987," which reflects a title change made in 1986. This 1990 volume continues the bulletin format started in 1988. As in 1989, this volume separates shorter contributions as Geologic Notes from more extensive Articles.This 1990 volume of 18 Articles and 4 Geologic Notes represents the broad range of USGS research activities carried out in Alaska over the past few years. These studies include topics on mineral and other resources such as gold (Y eend), platinum-group elements (Cathrall and Antweiler), coal (Roberts, Stricker, and Affolter), and petroleum (Howell, Bird, and others). Many other investigations provide background geochemical (Kilburn, Box, and others) and geologic data needed for resource evaluation as well as for determining the general geologic framework of Alaska, as in stratigraphic, sedimentologic, and paleontologic and radiometric age studies (Blodgett, Clough, and others; Box and Elder; Dickinson and Skipp; Marincovich and Moriya; McLean and Stanley; Stanley, Flores, and Wiley; Roeske, Pavlis, and others); geophysics (Sampson, Labson, and Long); structure and tectonic evaluations (Bradley and Kosky; Clendenen, Sliter, and Byrne; Karl; Csejtey; Howell, Johnsson, and others); and geomorphic and late Quaternary studies (Carter and Hillhouse; Galloway, Huebner, and others; McGimsey, Richter, and others; Nelson and Carter). These studies span nearly the entire State from the North Slope and Brooks Range to interior, southwestern, and south-central Alaska (fig. 1).Two bibliographies (White) at the end of the volume list (1) reports about Alaska in USGS publications released in 1990 and (2) reports about Alaska by USGS authors in publications outside the USGS in 1990. A bibliography and index of papers in past USGS circulars that are devoted to geologic research and accomplishments in Alaska (1975 to 1986) is published as USGS Open-File Report 87-420.
Kim, Yusung; Tomé, Wolfgang A.
2010-01-01
Summary Voxel based iso-Tumor Control Probability (TCP) maps and iso-Complication maps are proposed as a plan-review tool especially for functional image-guided intensity-modulated radiotherapy (IMRT) strategies such as selective boosting (dose painting) and conformal avoidance IMRT. The maps employ voxel-based phenomenological biological dose-response models for target volumes and normal organs. Two IMRT strategies for prostate cancer, namely conventional uniform IMRT delivering an EUD = 84 Gy (equivalent uniform dose) to the entire PTV and selective boosting delivering an EUD = 82 Gy to the entire PTV, are investigated, to illustrate the advantages of this approach over iso-dose maps. Conventional uniform IMRT did yield a more uniform isodose map to the entire PTV while selective boosting did result in a nonuniform isodose map. However, when employing voxel based iso-TCP maps selective boosting exhibited a more uniform tumor control probability map compared to what could be achieved using conventional uniform IMRT, which showed TCP cold spots in high-risk tumor subvolumes despite delivering a higher EUD to the entire PTV. Voxel based iso-Complication maps are presented for rectum and bladder, and their utilization for selective avoidance IMRT strategies are discussed. We believe as the need for functional image guided treatment planning grows, voxel based iso-TCP and iso-Complication maps will become an important tool to assess the integrity of such treatment plans. PMID:21151734
Dort, Jonathan; Trickey, Amber; Paige, John; Schwarz, Erin; Cecil, Tom; Coleman, Mark; Dunkin, Brian
2018-05-01
Continuing professional development (CPD) for the surgeon has been challenging because of a lack of standardized approaches of hands-on courses, resulting in poor post-course outcomes. To remedy this situation, SAGES has introduced the ADOPT program, implementing a standardized, long-term mentoring program as part of its hernia hands-on course. Previous work evaluating the pilot program showed increased adoption of learned procedures as well as increased confidence of the mentored surgeons. This manuscript describes the impact of such a program when it is instituted across an entire hands-on course. Following collection of pre-course benchmark data, all participants in the 2016 SAGES hands-on hernia course underwent structured, learner-focused instruction during the cadaveric lab. All faculty had completed a standardized teaching course in the Lapco TT format. Subsequently, course participants were enrolled in a year-long program involving longitudinal mentorship, webinars, conference calls, and coaching. Information about participant demographics, training, experience, self-reported case volumes, and confidence levels related to procedures were collected via survey 3 months prior to 9 months after the course. Twenty surgeons participated in the SAGES ADOPT 2016 hands-on hernia program. Of these, seventeen completed pre-course questionnaires (85%), ten completed the 3-month questionnaire (50%), and four completed the 9-month questionnaire (20%). Nine of ten respondents of the 3-month survey (90%) reported changes in their practice. In the 9-month survey, significant increases in the annualized procedural volumes were reported for open primary ventral hernia repair, open components separation, and mesh insertion for ventral hernia repair (p < 0.001). The expansion of the ADOPT program to an entire hands-on hernia course is both feasible and beneficial, with evidence of Kirkpatrick Levels 1-4a training effectiveness. This expanded success suggests that it is a useful blueprint for the CPD of surgeons wishing to learn new techniques and procedures for their patients.
NASA Astrophysics Data System (ADS)
Di Muro, A.; Metrich, N.; Daniele, V.; Rosi, M.; Armienti, P.; Fougeroux, T.; Deloule, E.; Arienzo, I.; Civetta, L.
2013-12-01
The 2007 eruption represents a major event in the recent history of Piton de la Fournaise volcano because it produced: i) the most voluminous lava field (at least 0.21 km3), ii) the most intense lava fountaining activity (>200 m high), iii) the largest SO2 plume (>230 kt), iv) the largest summit collapse (1 km wide x 0.34 km deep) and v) the main flank slip event (up to 1.4 m eastwards) ever documented at PdF. The bulk magma volume extruded during the 2007 eruptive sequence is similar to that emitted during the entire 1998-2006 period. As a whole, the volume of magma emitted during the whole 1998-2007 activity cycle is remarkably close to that estimated (~0.35 km3) for the shallow plumbing system of Piton de la Fournaise. The 2007 eruptive sequence consisted of three successive phases (February, March and April). The main caldera forming phase of April ended a 9 years long period (1998-2007) of continuous edifice inflation and frequent eruptive activity (3 eruptions per year on average). On the contrary, post-2007 activity punctuates a trend of continuous deflation and consists of small-volume summit eruptions of moderate/low MgO magmas and frequent shallow magma intrusions. The 2007 lavas and pyroclasts cover the complete range of textures and crystal content an composition typically found in PdF products. The broad range of textures and the large volumes of pyroclasts, lava and gas emitted in 2007 provide an unique and exceptional record of the time-integrated evolution of PdF magma, and represent an unique opportunity to image the volcano plumbing system and bring new constraints on the processes controlling its magmatic and volatile budget. We here address these issues by using an unprecedented geochemical dataset (major, volatile and trace elements, Sr-Nd isotopes) on bulk rocks, minerals, glass inclusions and glass matrices from a very detailed sample set, representative of the time evolution of extruded magma during the entire 2007 eruptive sequence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schild, Michael H.; Schild, Steven E., E-mail: sschild@mayo.edu; Wong, William W.
Purpose: This report describes the long-term outcomes of a prospective trial of intensity modulated radiation therapy (IMRT), integrating a {sup 111}In capromab pendetide (ProstaScint) scan-directed simultaneous integrated boost (SIB) for localized prostate cancer. Methods and Materials: Seventy-one patients with T1N0M0 to T4N0M0 prostate cancer were enrolled, and their ProstaScint and pelvic computed tomography scans were coregistered for treatment planning. The entire prostate received 75.6 Gy in 42 fractions with IMRT, whereas regions of increased uptake on ProstaScint scans received 82 Gy as an SIB. Patients with intermediate- and high-risk disease also received 6 months and 12 months of adjuvant hormonal therapy, respectively. Results: The studymore » enrolled 31 low-, 30 intermediate-, and 10 high-risk patients. The median follow-up was 120 months (range, 24-150 months). The 10-year biochemical control rates were 85% for the entire cohort and 84%, 84%, and 90% for patients with low-, intermediate-, and high-risk disease, respectively. The 10-year survival rate of the entire cohort was 69%. Pretreatment prostate-specific antigen level >10 ng/mL and boost volume of >10% of the prostate volume were significantly associated with poorer biochemical control and survival. The outcomes were compared with those of a cohort of 302 patients treated similarly but without the SIB and followed up for a median of 91 months (range, 6-138 months). The 5- and 10-year biochemical control rates were 86% and 61%, respectively, in patients without the SIB compared with 94% and 85%, respectively, in patients in this trial who received the SIB (P=.02). The cohort that received an SIB did not have increased toxicity. Conclusions: The described IMRT strategy, integrating multiple imaging modalities to administer 75.6 Gy to the entire prostate with a boost dose of 82 Gy, was feasible. The addition of the SIB was associated with greater biochemical control but not toxicity. Modern imaging technology can be used to locally intensify the dose to tumors and spare normal tissues, producing very favorable long-term biochemical disease control.« less
NASA Astrophysics Data System (ADS)
Hiramatsu, Yuya; Muramatsu, Chisako; Kobayashi, Hironobu; Hara, Takeshi; Fujita, Hiroshi
2017-03-01
Breast cancer screening with mammography and ultrasonography is expected to improve sensitivity compared with mammography alone, especially for women with dense breast. An automated breast volume scanner (ABVS) provides the operator-independent whole breast data which facilitate double reading and comparison with past exams, contralateral breast, and multimodality images. However, large volumetric data in screening practice increase radiologists' workload. Therefore, our goal is to develop a computer-aided detection scheme of breast masses in ABVS data for assisting radiologists' diagnosis and comparison with mammographic findings. In this study, false positive (FP) reduction scheme using deep convolutional neural network (DCNN) was investigated. For training DCNN, true positive and FP samples were obtained from the result of our initial mass detection scheme using the vector convergence filter. Regions of interest including the detected regions were extracted from the multiplanar reconstraction slices. We investigated methods to select effective FP samples for training the DCNN. Based on the free response receiver operating characteristic analysis, simple random sampling from the entire candidates was most effective in this study. Using DCNN, the number of FPs could be reduced by 60%, while retaining 90% of true masses. The result indicates the potential usefulness of DCNN for FP reduction in automated mass detection on ABVS images.
Belotti, Francesco; Doglietto, Francesco; Schreiber, Alberto; Ravanelli, Marco; Ferrari, Marco; Lancini, Davide; Rampinelli, Vittorio; Hirtler, Lena; Buffoli, Barbara; Bolzoni Villaret, Andrea; Maroldi, Roberto; Rodella, Luigi Fabrizio; Nicolai, Piero; Fontanella, Marco Maria
2018-01-01
Endoscopic visualization does not necessarily correspond to an adequate working space. The need for balancing invasiveness and adequacy of sellar tumor exposure has recently led to the description of multiple endoscopic endonasal transsphenoidal approaches. Comparative anatomic data on these variants are lacking. We sought to quantitatively compare endoscopic endonasal transsphenoidal approaches to the sella and parasellar region, using the concept of "surgical pyramid." Four endoscopic transsphenoidal approaches were performed in 10 injected specimens: 1) hemisphenoidotomy; 2) transrostral; 3) extended transrostral (with superior turbinectomy); and 4) extended transrostral with posterior ethmoidectomy. ApproachViewer software (part of GTx-Eyes II, University Health Network, Toronto, Canada) with a dedicated navigation system was used to quantify the surgical pyramid volume, as well as exposure of sellar and parasellar areas. Statistical analyses were performed with Friedman's tests and Nemenyi's procedure. Hemisphenoidotomy provided limited exposure of the sellar area and a small working volume. A transrostral approach was necessary to expose the entire sella. Exposure of lateral parasellar areas required superior turbinectomy or posterior ethmoidectomy. The differences between each of the modules was statistically significant. The present study validates, from an anatomic point of view, a modular classification of endoscopic endonasal transsphenoidal approaches to the sellar region. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Pawar, N. R.; Chimankar, O. P.; Bhandakkar, V. D.; Padole, N. N.
2012-12-01
The ultrasonic velocity (u), absorption (α), density (ρ), and viscosity (η) has been measured at different frequencies (1MHz to 10MHz) in the binary mixtures of cyclohexane with acrylonitriile over the entire range of composition at temperature 303K. Vander Waal's constant (b), adiabatic compressibility (βa), acoustic impedance (Z), molar volume (V), free length (Lf), free volume, internal pressure, intermolecular radius and relative association have been also calculated. A special application for acrylonitrile is in the manufacture of carbon fibers. These are produced by paralysis of oriented poly acrylonitrile fibers and are used to reinforce composites for high-performance applications in the aircraft, defense and aerospace industries. Other applications of acrylonitrile are in the production of fatty amines, ion exchange resins and fatty amine amides used in cosmetics, adhesives, corrosion inhibitors and water-treatment resins. Cyclohexane derivatives can be used for the synthesis of pharmaceuticals, dyes, herbicides, plant growth regulator, plasticizers, rubber chemicals, nylon, cyclamens and other organic compounds. In the view of these extensive applications of acrylonitrile and cyclohexane in the engineering process, textile and pharmaceutical industries present study provides qualitative information regarding the nature and strength of interaction in the liquid mixtures through derive parameters from ultrasonic velocity and absorption measurement.
NASA Technical Reports Server (NTRS)
Srivastava, Deepak; Meyyappan, Meyya; Yan, Jerry (Technical Monitor)
2000-01-01
Advanced miniaturization, a key thrust area to enable new science and exploration missions, provides ultrasmall sensors, power sources, communication, navigation, and propulsion systems with very low mass, volume, and power consumption. Revolutions in electronics and computing will allow reconfigurable, autonomous, 'thinking' spacecraft. Nanotechnology presents a whole new spectrum of opportunities to build device components and systems for entirely new space architectures: (1) networks of ultrasmall probes on planetary surfaces; (2) micro-rovers that drive, hop, fly, and burrow; and (3) collections of microspacecraft making a variety of measurements.
The Coast Artillery Journal. Volume 77, Number 5, September-October 1934
1934-10-01
company, was never refused. Cochrane de- plain covered with alternate patches of jungle and cogon cided the question the only way it could have been de... grass and occasionally it dipped to cross and recross a small 1934 JUNliLn WARFARE 345 stream that flowed in a rocky bed between banks entirely...riRemenuntil that moment completely hidden m the grass at the side of the trail. As the sheet of smoke and flame burst forth into the faces of the leading
SeaFrame. From Research to Reality Supporting the Fleet. Volume 4, Issue 3, 2008
2008-01-01
propeller’s inflow in the towing tank with Pitot tubes and later by Laser Doppler Velocimetry Provided insight into viscous effects on propeller...group. Comparing new to old is shocking . For example, if A and B turbine generators are carrying the entire ship’s load and an operator wanted to bring...page, containing many PLC diagnostics . The PLC’s web page can be accessed from any PC on the network and displays current PLC configuration and
Army Sustainment. Volume 43, Issue 4, July-August 2011
2011-08-01
ManageMent coMMand. he holdS a B.a. degree in criMinal juStice froM con- cordia college in Michigan and iS level ii certified in PrograM ManageMent and...got there. Think about the entire process, from raw-materials extraction to transformation at a plant or mill, movement of these materials to a manu...facturing plant , assembly of the product’s various components, packaging and further movement to a warehouse or distribution center, delivery to the
Collected Works of Mao Tse-Tung (1917-1949). Volumes 5-6
1978-11-16
general mobilization of the army, navy, and air force and the people of all of China for a sacred anti-Japanese national revolutionary war , in order to...Japan Red Army of China have continuously appealed to the people of the entire nation to unite and wage war against Japan. They sent the main force of...organize, wage a national revolutionary war , and oust Japanese imperial- ism and the Chinese warlords from the territory of Inner Mongolia, no one will
1980-02-01
migration of the chemical mass in the fluid volume according to two entirely different means, yet governed by the same form of the equation: molecular ...pressure or temperature gradients, gravitational or other body forces, or bulk fluid motion, is observed as molecular diffusion. In general, the...need be made at this stage as to whether the diffusion of a released mass in the fluid is molecular or turbulent in nature. The general form of the one
NASA Astrophysics Data System (ADS)
Phillips, Carolyn L.; Anderson, Joshua A.; Huber, Greg; Glotzer, Sharon C.
2012-05-01
We present filling as a type of spatial subdivision problem similar to covering and packing. Filling addresses the optimal placement of overlapping objects lying entirely inside an arbitrary shape so as to cover the most interior volume. In n-dimensional space, if the objects are polydisperse n-balls, we show that solutions correspond to sets of maximal n-balls. For polygons, we provide a heuristic for finding solutions of maximal disks. We consider the properties of ideal distributions of N disks as N→∞. We note an analogy with energy landscapes.
Short rise time intense electron beam generator
Olson, Craig L.
1987-01-01
A generator for producing an intense relativistic electron beam having a subnanosecond current rise time includes a conventional generator of intense relativistic electrons feeding into a short electrically conductive drift tube including a cavity containing a working gas at a low enough pressure to prevent the input beam from significantly ionizing the working gas. Ionizing means such as a laser simultaneously ionize the entire volume of working gas in the cavity to generate an output beam having a rise time less than one nanosecond.
The Coast Artillery Journal. Volume 82, Number 4 July-August 1939
1939-08-01
instruction of those examinees requiring it. 8. They save time and money , especially in National Guard organizations where boards generally call for extra...renCIes. Neutral countries were willing to lend money part of them, and it is also quite certain that the total of and .grant credit because in years of...And anyhow, where was the money coming from? The central govern- ment had few sources of income; it was entirely depend- ent upon the fiercely
Turbofan forced mixer-nozzle internal flowfield. Volume 2: Computational fluid dynamic predictions
NASA Technical Reports Server (NTRS)
Werle, M. J.; Vasta, V. N.
1982-01-01
A general program was conducted to develop and assess a computational method for predicting the flow properties in a turbofan forced mixed duct. The detail assessment of the resulting computer code is presented. It was found that the code provided excellent predictions of the kinematics of the mixing process throughout the entire length of the mixer nozzle. The thermal mixing process between the hot core and cold fan flows was found to be well represented in the low speed portion of the flowfield.
Nuclear Safety. Technical progress journal, April--June 1996: Volume 37, No. 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muhlheim, M D
1996-01-01
This journal covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities.
Nuclear Safety. Technical progress journal, January--March 1994: Volume 35, No. 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silver, E G
1994-01-01
This is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities.
ERIC Educational Resources Information Center
Kozaczka, Stanley J.
This essay outlines the development, present condition, and future direction of the 20,000-volume Polish research collection at Alliance College, located in Cambridge Springs, Pennsylvania. Alliance College was founded in 1912 by the Polish National Alliance (PNA), a life insurance fraternal organization. In 1931 its entire library collection was…
Parameters, U.S. Army War College Quarterly. Volume 18, Number 3, September 1988
1988-09-01
century policy of opposing the hegemony of any single power in East Asia , embarked on quasi- hegemonic policies of its own. As of now, dangers to the...so often made against US policies in Asia . True, the entire apparatus collapsed in January 1947 when the Marshall mission was ter- minated as...affairs for East Asia . Since 1975 he has been a lecturer at the Naval War College. September /988 97 This threat was primarily naval and air , although
Short rise time intense electron beam generator
Olson, C.L.
1984-03-16
A generator for producing an intense relativisitc electron beam having a subnanosecond current rise time includes a conventional generator of intense relativistic electrons feeding into a short electrically conductive drift tube including a cavity containing a working gas at a low enough pressure to prevent the input beam from significantly ionizing the working gas. Ionizing means such as a laser simultaneously ionize the entire volume of working gas in the cavity to generate an output beam having a rise time less than one nanosecond.
The Coast Artillery Journal. Volume 82, Number 1, January-February 1939
1939-02-01
commerce has been created , assisted and jealously guarded by a powerful fleet, and history shows that England has alw~vs resorted to war whenever her...p3rt in modern warfare. Creating 3n inrerest in w3rning nets and blackouts directed the public mind roward the entire subject of passive defense...causes of currem events in Palestine, which h,l\\’e created a condition that borders on anarch\\’ and h.ls forced the introduction of martial law, lie in
2012-07-01
Composites 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Larry R. Holmes, Jr., James P. Wolbert, and Jared M...greater than 10 kPa (1.5 psi) pressure change in the vacuum bag. A redundant second vacuum bag was applied over the entire layup to further protect...In order to maintain the increased fvf and decrease the processing time, a second experimental process was conducted using a compacted and pre
Ultraviolet Spectra of Normal Spiral Galaxies
NASA Technical Reports Server (NTRS)
Kinney, Anne
1997-01-01
The data related to this grant on the Ultraviolet Spectra of Normal Spiral Galaxies have been entirely reduced and analyzed. It is incorporated into templates of Spiral galaxies used in the calculation of K corrections towards the understanding of high redshift galaxies. The main paper was published in the Astrophysical Journal, August 1996, Volume 467, page 38. The data was also used in another publication, The Spectral Energy Distribution of Normal Starburst and Active Galaxies, June 1997, preprint series No. 1158. Copies of both have been attached.
1998-04-01
Valley (Kroeber & Heizer 1970). In 1972, the Bureau of Indian Affairs listed only 11 individuals claiming Patwin ancestry in the entire territory...facility from the dredge disposal area to the upland open space scenic resource area would render this facility visible from viewpoints with . high...take. The COE probably would not issue a permit unless the USFWS rendered a "non-jeopardy" Biological Opinion, which would incorporate mitigations for
Method of determining forest production from remotely sensed forest parameters
Corey, J.C.; Mackey, H.E. Jr.
1987-08-31
A method of determining forest production entirely from remotely sensed data in which remotely sensed multispectral scanner (MSS) data on forest 5 composition is combined with remotely sensed radar imaging data on forest stand biophysical parameters to provide a measure of forest production. A high correlation has been found to exist between the remotely sensed radar imaging data and on site measurements of biophysical 10 parameters such as stand height, diameter at breast height, total tree height, mean area per tree, and timber stand volume.
Press On! Selected Works of General Donn A. Starry. Volume 1
2009-01-01
long years in the National Guard. At age four, something of a mascot to his father’s outfit, Starry was made a brevet first lieutenant in the Kansas... rejuvenation of the entire Army through many other avenues as well.” Starry seldom gave a speech in which he did not include historical references...1929, and I was four years and some months of age when Gov. Clyde M. Reed assigned me to my father for quarters, rations, discipline, and for such
Air & Space Power Journal. Volume 22, Number 1, Spring 2008
2008-01-01
Braganca, USAF Naval Air Station Patuxent River, Maryland Dr. Kendall K. Brown NASA Marshall Space Flight Center Col Steven D. Carey, USAF...bunch of ‘Bs’ I’ve ever heard of.” At first there was no reaction to my remarks, but then the entire room erupted in shouts and cheers! All I had...present itself. Being in Our Profession Is All about Service to Others I am reminded of the photograph of the chief master sergeant stationed in Iraq
Command History. 1967. Volume 1. Sanitized
1967-01-01
the Politburo of the Lao Dong Party. This top political control center included Le Duan, General Vo Nguyen Glap, Truong Chinh , Le Duc Tho, and until...the support area Naval Support Activity (NSA) Da Nang’s vital intra- coastal trans -shipment route from the deep water port at Da Nang northward to...under the energetic guidance of MG Nguyen Duc Thang, reviewed PAGE 6 OF 1340 PAGES I% the entire process of RD and set to the task of revitalizing the
European Scientific Notes. Volume 35, Number 4,
1981-04-30
Physics in 1.915. Sir Lawrence used have utilized a laser excitation source X-ray analysis to obtain the first struc- consisting of a CW rhodamine 6G dye...imported. In case of a war or 44% of the samples that were tested in other crisis, it is entirely possilble summer positively determined the pros- that...that sibility that it would be the innocent this is due to the fact that there is victim of a war in lhich it was neutral, more sunshine in summer than
WSTIAC: Weapon Systems Technology Information Analysis Center. Volume 6, Number 1
2005-01-01
official documentation. 2 WS"IAE Newslelter Winter 2005 Lobster Robo [s (Continued from page 1) When compared to terrestrial arthropods, underwater...were partially offset by a net during the S&T phase, could help ease the transition to the decrease of planned quantities to be purchased (-$24.4...environment to archive the ly always involves the use of a Test and Evaluation Master development of an entire system, on paper qnd/or elec- Plan (TEMP). Test
1977-01-01
groups who used this ratio should be considered. them to process wild seeds and other vegeta material. The trough metate has been considered a specialized...transition and as an indi- was composed entirely of jar formswith wide oriface. cation of the importance assumed by wild vegetal ma- not as difficult to...For example. Ovis/Capra meat is con- faunal resource utilization from the excavated site loca- sidered most edible when the animal is young. Meat
Yu, Kevin K.; Cheung, Charlton; Chua, Siew E.; McAlonan, Gráinne M.
2011-01-01
Background The question of whether Asperger syndrome can be distinguished from autism has attracted much debate and may even incur delay in diagnosis and intervention. Accordingly, there has been a proposal for Asperger syndrome to be subsumed under autism in the forthcoming Diagnostic and Statistical Manual of Mental Disorders, fifth edition, in 2013. One approach to resolve this question has been to adopt the criterion of absence of clinically significant language or cognitive delay — essentially, the “absence of language delay.” To our knowledge, this is the first meta-analysis of magnetic resonance imaging (MRI) studies of people with autism to compare absence with presence of language delay. It capitalizes on the voxel-based morphometry (VBM) approach to systematically explore the whole brain for anatomic correlates of delay and no delay in language acquisition in people with autism spectrum disorders. Methods We conducted a systematic search for VBM MRI studies of grey matter volume in people with autism. Studies with a majority (at least 70%) of participants with autism diagnoses and a history of language delay were assigned to the autism group (n = 151, control n = 190). Those with a majority (at least 70%) of individuals with autism diagnoses and no language delay were assigned to the Asperger syndrome group (n = 149, control n = 214). We entered study coordinates into anatomic likelihood estimation meta-analysis software with sampling size weighting to compare grey matter summary maps driven by Asperger syndrome or autism. Results The summary autism grey matter map showed lower volumes in the cerebellum, right uncus, dorsal hippocampus and middle temporal gyrus compared with controls; grey matter volumes were greater in the bilateral caudate, prefrontal lobe and ventral temporal lobe. The summary Asperger syndrome map indicated lower grey matter volumes in the bilateral amygdala/hippocampal gyrus and prefrontal lobe, left occipital gyrus, right cerebellum, putamen and precuneus compared with controls; grey matter volumes were greater in more limited regions, including the bilateral inferior parietal lobule and the left fusiform gyrus. Both Asperger syndrome and autism studies reported volume increase in clusters in the ventral temporal lobe of the left hemisphere. Limitations We assigned studies to autism and Asperger syndrome groups for separate analyses of the data and did not carry out a direct statistical group comparison. In addition, studies available for analysis did not capture the entire spectrum, therefore we cannot be certain that our findings apply to a wider population than that sampled. Conclusion Whereas grey matter differences in people with Asperger syndrome compared with controls are sparser than those reported in studies of people with autism, the distribution and direction of differences in each category are distinctive. PMID:21406158
Yu, Kevin K; Cheung, Charlton; Chua, Siew E; McAlonan, Gráinne M
2011-11-01
The question of whether Asperger syndrome can be distinguished from autism has attracted much debate and may even incur delay in diagnosis and intervention. Accordingly, there has been a proposal for Asperger syndrome to be subsumed under autism in the forthcoming Diagnostic and Statistical Manual of Mental Disorders, fifth edition, in 2013. One approach to resolve this question has been to adopt the criterion of absence of clinically significant language or cognitive delay--essentially, the "absence of language delay." To our knowledge, this is the first meta-analysis of magnetic resonance imaging (MRI) studies of people with autism to compare absence with presence of language delay. It capitalizes on the voxel-based morphometry (VBM) approach to systematically explore the whole brain for anatomic correlates of delay and no delay in language acquisition in people with autism spectrum disorders. We conducted a systematic search for VBM MRI studies of grey matter volume in people with autism. Studies with a majority (at least 70%) of participants with autism diagnoses and a history of language delay were assigned to the autism group (n = 151, control n = 190). Those with a majority (at least 70%) of individuals with autism diagnoses and no language delay were assigned to the Asperger syndrome group (n = 149, control n = 214). We entered study coordinates into anatomic likelihood estimation meta-analysis software with sampling size weighting to compare grey matter summary maps driven by Asperger syndrome or autism. The summary autism grey matter map showed lower volumes in the cerebellum, right uncus, dorsal hippocampus and middle temporal gyrus compared with controls; grey matter volumes were greater in the bilateral caudate, prefrontal lobe and ventral temporal lobe. The summary Asperger syndrome map indicated lower grey matter volumes in the bilateral amygdala/hippocampal gyrus and prefrontal lobe, left occipital gyrus, right cerebellum, putamen and precuneus compared with controls; grey matter volumes were greater in more limited regions, including the bilateral inferior parietal lobule and the left fusiform gyrus. Both Asperger syndrome and autism studies reported volume increase in clusters in the ventral temporal lobe of the left hemisphere. We assigned studies to autism and Asperger syndrome groups for separate analyses of the data and did not carry out a direct statistical group comparison. In addition, studies available for analysis did not capture the entire spectrum, therefore we cannot be certain that our findings apply to a wider population than that sampled. Whereas grey matter differences in people with Asperger syndrome compared with controls are sparser than those reported in studies of people with autism, the distribution and direction of differences in each category are distinctive. © 2011 Canadian Medical Association
Compressibilities and Volume Fluctuations of Archaeal Tetraether Liposomes
Chong, Parkson Lee-Gau; Sulc, Michael; Winter, Roland
2010-01-01
Bipolar tetraether lipids (BTLs) are abundant in crenarchaeota, which thrive in both thermophilic and nonthermophilic environments, with wide-ranging growth temperatures (4–108°C). BTL liposomes can serve as membrane models to explore the role of BTLs in the thermal stability of the plasma membrane of crenarchaeota. In this study, we focus on the liposomes made of the polar lipid fraction E (PLFE). PLFE is one of the main BTLs isolated from the thermoacidophilic crenarchaeon Sulfolobus acidocaldarius. Using molecular acoustics (ultrasound velocimetry and densimetry), pressure perturbation calorimetry, and differential scanning calorimetry, we have determined partial specific adiabatic and isothermal compressibility, their respective compressibility coefficients, partial specific volume, and relative volume fluctuations of PLFE large unilamellar vesicles (LUVs) over a wide range of temperatures (20–85°C). The results are compared with those obtained from liposomes made of dipalmitoyl-L-α-phosphatidylcholine (DPPC), a conventional monopolar diester lipid. We found that, in the entire temperature range examined, compressibilities of PLFE LUVs are low, comparable to those found in gel state of DPPC. Relative volume fluctuations of PLFE LUVs at any given temperature examined are 1.6–2.2 times more damped than those found in DPPC LUVs. Both compressibilities and relative volume fluctuations in PLFE LUVs are much less temperature-sensitive than those in DPPC liposomes. The isothermal compressibility coefficient (βTlipid) of PLFE LUVs changes from 3.59 × 10−10 Pa−1 at 25°C to 4.08 × 10−10 Pa−1 at 78°C. Volume fluctuations of PLFE LUVs change only 0.25% from 30°C to 80°C. The highly damped volume fluctuations and their low temperature sensitivity, echo that PLFE liposomes are rigid and tightly packed. To our knowledge, the data provide a deeper understanding of lipid packing in PLFE liposomes than has been previously reported, as well as a molecular explanation for the low solute permeation and limited membrane lateral motion. The obtained results may help to establish new strategies for rational design of stable BTL-based liposomes for drug/vaccine delivery. PMID:21081080
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-01
Before disposing of transuranic radioactive waste in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments (PAs) of the WIPP for the DOE to provide interim guidance while preparing for a final compliance evaluation. This volume of the 1992 PA contains results of uncertainty and sensitivity analyses with respect to migration of gas and brine from the undisturbed repository. Additional information about the 1992 PA is provided in other volumes. Volume 1 containsmore » an overview of WIPP PA and results of a preliminary comparison with 40 CFR 191, Subpart B. Volume 2 describes the technical basis for the performance assessment, including descriptions of the linked computational models used in the Monte Carlo analyses. Volume 3 contains the reference data base and values for input parameters used in consequence and probability modeling. Volume 4 contains uncertainty and sensitivity analyses with respect to the EPA`s Environmental Standards for the Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B). Finally, guidance derived from the entire 1992 PA is presented in Volume 6. Results of the 1992 uncertainty and sensitivity analyses indicate that, conditional on the modeling assumptions and the assigned parameter-value distributions, the most important parameters for which uncertainty has the potential to affect gas and brine migration from the undisturbed repository are: initial liquid saturation in the waste, anhydrite permeability, biodegradation-reaction stoichiometry, gas-generation rates for both corrosion and biodegradation under inundated conditions, and the permeability of the long-term shaft seal.« less