A traceability procedure has been established which allows specialty gas producers to prepare gaseous pollutant Certified Reference Materials (CRMs). The accuracy, stability and homogeneity of the CRMs approach those of NBS Standard Reference Materials (SRMs). Part of this proced...
A traceability procedure has been established which allows specialty gas producers to prepare gaseous pollutant Certified Reference Materials (CRM's). The accuracy, stability and homogeneity of the CRM's approach those of NBS Standard Reference Materials (SRM's). As of October 19...
Wise, Stephen A; Poster, Dianne L; Kucklick, John R; Keller, Jennifer M; Vanderpol, Stacy S; Sander, Lane C; Schantz, Michele M
2006-10-01
For the past 25 years the National Institute of Standards and Technology (NIST) has developed certified reference materials (CRMs), known as standard reference materials (SRMs), for determination of organic contaminants in environmental matrices. Assignment of certified concentrations has usually been based on combining results from two or more independent analytical methods. The first-generation environmental-matrix SRMs were issued with certified concentrations for a limited number (5 to 10) of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Improvements in the analytical certification approach significantly expanded the number and classes of contaminants determined. Environmental-matrix SRMs currently available include air and diesel particulate matter, coal tar, marine and river sediment, mussel tissue, fish oil and tissue, and human serum, with concentrations typically assigned for 50 to 90 organic contaminants, for example PAHs, nitro-substituted PAHs, PCBs, chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs).
Quevauviller, P; Bennink, D; Bøwadt, S
2001-05-01
It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.
Schantz, Michele M; Benner, Bruce A; Heckert, N Alan; Sander, Lane C; Sharpless, Katherine E; Vander Pol, Stacy S; Vasquez, Y; Villegas, M; Wise, Stephen A; Alwis, K Udeni; Blount, Benjamin C; Calafat, Antonia M; Li, Zheng; Silva, Manori J; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G; Sjödin, Andreas
2015-04-01
Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers' Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants.
Schantz, Michele M.; Benner, Bruce A.; Heckert, N. Alan; Sander, Lane C.; Sharpless, Katherine E.; Vander Pol, Stacy S.; Vasquez, Y.; Villegas, M.; Wise, Stephen A.; Alwis, K. Udeni; Blount, Benjamin C.; Calafat, Antonia M.; Li, Zheng; Silva, Manori J.; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G.; Sjödin, Andreas
2016-01-01
Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers’ Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers’ Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants. PMID:25651899
Field joint environmental protection system vibration/pressurization qualification
NASA Technical Reports Server (NTRS)
Cook, M.
1989-01-01
The procedures used and results obtained from vibration testing the redesigned solid rocket motor (RSRM) field joint environmental protection system (FJEPS), hereafter referred to as the joint protection system (JPS) are documented. The major purposes were to certify that the flight-designed JPS will withstand the dynamic environmental conditions of the redesigned solid rocket booster, and to certify that the cartridge check valve (vent valve) will relieve pressure build-up under the JPS during the initial 120 sec of flight. Also, an evaluation of the extruded cork insulation bonding was performed after the vibration testing.
Certified reference materials and reference methods for nuclear safeguards and security.
Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y
2013-11-01
Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and have therefore reached high level of attention for safeguards authorities. Furthermore, IRMM initiated and coordinated the development of a Modified Total Evaporation (MTE) technique for accurate abundance ratio measurements of the "minor" isotope-amount ratios of uranium and plutonium in nuclear material and, in combination with a multi-dynamic measurement technique and filament carburization, in environmental samples. Currently IRMM is engaged in a study on the development of plutonium reference materials for "age dating", i.e. determination of the time elapsed since the last separation of plutonium from its daughter nuclides. The decay of a radioactive parent isotope and the build-up of a corresponding amount of daughter nuclide serve as chronometer to calculate the age of a nuclear material. There are no such certified reference materials available yet. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalavapudi, M.; Iyengar, V.
Increased industrial activities in developing countries have degraded the environment, and the impact on the environment is further magnified because of an ever-increasing population, the prime receptors. Independent of the geographical location, it is possible to adopt effective strategies to solve environmental problems. In the United States, waste characterization and remediation practices are commonly used for quantifying toxic contaminants in air, water, and soil. Previously, such procedures were extraneous, ineffective, and cost-intensive. Reconciliation between the government and stakeholders, reinforced by valid data analysis and environmental exposure assessments, has allowed the {open_quotes}Brownfields{close_quotes} to be a successful approach. Certified reference materials andmore » standard reference materials from the National Institute of Standards (NIST) are indispensable tools for solving environmental problems and help to validate data quality and the demands of legal metrology. Certified reference materials are commonly available, essential tools for developing good quality secondary and in-house reference materials that also enhance analytical quality. This paper cites examples of environmental conditions in developing countries, i.e., industrial pollution problems in India, polluted beaches in Brazil, and deteriorating air quality in countries, such as Korea, China, and Japan. The paper also highlights practical and effective approaches for remediating these problems. 23 refs., 7 figs., 1 tab.« less
Cao, X; Xu, X; Cui, W; Xi, Z
2001-08-01
The development and certification of a coal fly ash certified reference material (CRM) for polycyclic aromatic hydrocarbons (PAH) is described; this is the first natural matrix CRM for organic environmental analysis in China. The homogeneity and stability of this material have been tested by HPLC. The concentrations of several PAH were determined by use of two independent, different methods--solvent extraction-HPLC analysis with UV detection coupled with fluorescence detection (FLD) and solvent extraction, isolation with a silica column, and GC analysis with flame ionization detection (FID). Five certified values were determined: phenanthrene 7.1 +/- 2.6 microg g(-1), anthracene 2.0 +/- 0.8 microg g(-1), fluoranthene 7.4 +/- 1.9 microg g(-1), pyrene 7 +/- 2 microg g(-1), and benzo[a]pyrene 1.3 +/- 0.3 microg g(-1). Reference values for several other PAH are also suggested.
Fassett, J D; MacDonald, B S
2001-08-01
The National Institute of Standards and Technology (NIST) has had a major quality-assurance role in the federal effort to reduce lead poisoning of children in the United States through its mission of ensuring the accuracy of chemical measurements. NIST certifies reference materials (standard reference materials--SRMs) that are used to benchmark measurements by secondary and field methods of analysis--to ensure that decisions of great health and economic impact are soundly based on good measurement science. Over the past 10 years, in cooperation with the US Environmental Protection Agency (EPA), US Department of Housing and Urban Development (HUD), and the United States Geological Survey (USGS), NIST has prepared and certified SRMs for lead content in soil, indoor dust, and paint. The role of these materials in meeting regulatory and abatement needs is described and their certified values are summarized.
Tolosa, Imma; Cassi, Roberto; Huertas, David
2018-04-11
A new marine sediment certified reference material (IAEA 459) with very low concentrations (μg kg -1 ) for a variety of persistent organic contaminants (POPs) listed by the Stockholm Convention, as well as other POPs and priority substances (PSs) listed in many environmental monitoring programs was developed by the IAEA. The sediment material was collected from the Ham River estuary in South Korea, and the assigned final values were derived from robust statistics on the results provided by selected laboratories which demonstrated technical and quality competence, following the guidance given in ISO Guide 35. The robust mean of the laboratory means was assigned as certified values, for those compounds where the assigned value was derived from at least five datasets and its relative expanded uncertainty was less than 40% of the assigned value (most of the values ranging from 8 to 20%). All the datasets were derived from at least two different analytical techniques which have allowed the assignment of certified concentrations for 22 polychlorinated biphenyl (PCB) congeners, 6 organochlorinated (OC) pesticides, 5 polybrominated diphenyl ethers (PBDEs), and 18 polycyclic aromatic hydrocarbon (PAHs). Mass fractions of compounds that did not fulfill the criteria of certification are considered information values, which include 29 PAHs, 11 PCBs, 16 OC pesticides, and 5 PBDEs. The extensive characterization and associated uncertainties at concentration levels close to the marine sediment quality guidelines will make CRM 459 a valuable matrix reference material for use in marine environmental monitoring programs.
Enantiomer fractions of polychlorinated biphenyls in three selected Standard Reference Materials.
Morrissey, Joshua A; Bleackley, Derek S; Warner, Nicholas A; Wong, Charles S
2007-01-01
The enantiomer composition of six chiral polychlorinated biphenyls (PCBs) were measured in three different certified Standard Reference Materials (SRMs) from the US National Institute of Standards and Technology (NIST): SRM 1946 (Lake Superior fish tissue), SRM 1939a (PCB Congeners in Hudson River Sediment), and SRM 2978 (organic contaminants in mussel tissue--Raritan Bay, New Jersey) to aid in quality assurance/quality control methodologies in the study of chiral pollutants in sediments and biota. Enantiomer fractions (EFs) of PCBs 91, 95, 136, 149, 174, and 183 were measured using a suite of chiral columns by gas chromatography/mass spectrometry. Concentrations of target analytes were in agreement with certified values. Target analyte EFs in reference materials were measured precisely (<2% relative standard deviation), indicating the utility of SRM in quality assurance/control methodologies for analyses of chiral compounds in environmental samples. Measured EFs were also in agreement with previously published analyses of similar samples, indicating that similar enantioselective processes were taking place in these environmental matrices.
Neves, Laura A; Almeida, Renato R R; Rego, Eliane P; Rodrigues, Janaína Marques; de Carvalho, Lucas Junqueira; de M Goulart, Ana Letícia
2015-04-01
The Brazilian Metrology Institute (National Institute of Metrology, Quality, and Technology, Inmetro) has been developing a certified reference material (CRM) of the volatile organic compounds benzene; toluene; ethylbenzene; and ortho, meta, and para-xylenes (BTEX) in methanol, to ensure quality control for environmental-analysis measurements. The objective of this paper is to present the results of certification studies: uncertainty estimates related to characterization, a homogeneity study, and a stability study on a single lot of CRM composed of BTEX in methanol. The method used analysis of variance (ANOVA), a statistical tool, to evaluate the homogeneity and stability of the BTEX CRM, which complies with ISO Guide 30 series. The homogeneity and stability of the BTEX CRM was confirmed for all analytes and their respective properties. All the procedures used in this study complied with ISO GUIDE 34, ISO GUIDE 35, and the guide to the expression of uncertainty of measurement (GUM).
Nuclear reference materials to meet the changing needs of the global nuclear community
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, H.R.; Gradle, C.G.; Narayanan, U.I.
New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less
Gates, Kevin; Chang, Ning; Dilek, Isil; Jian, Huahua; Pogue, Sherri; Sreenivasan, Uma
2009-10-01
Certified solution standards are widely used in forensic toxicological, clinical/diagnostic, and environmental testing. Typically, these standards are purchased as ampouled solutions with a certified concentration. Vendors present concentration and uncertainty differently on their Certificates of Analysis. Understanding the factors that impact uncertainty and which factors have been considered in the vendor's assignment of uncertainty are critical to understanding the accuracy of the standard and the impact on testing results. Understanding these variables is also important for laboratories seeking to comply with ISO/IEC 17025 requirements and for those preparing reference solutions from neat materials at the bench. The impact of uncertainty associated with the neat material purity (including residual water, residual solvent, and inorganic content), mass measurement (weighing techniques), and solvent addition (solution density) on the overall uncertainty of the certified concentration is described along with uncertainty calculations.
Recent developments in the field of environmental reference materials at the JRC Ispra.
Muntau, H
2001-06-01
The production of reference materials for environmental analysis started in the Joint Research Centre at Ispra/Italy in 1972 with the objective of later certification by the BCR, but for obvious budget reasons only a fraction of the total production achieved at Ispra ever reached certification level, although all materials were produced according to the severe quality requirements requested for certified reference materials. Therefore, the materials not destinated to certification are in growing demand as inter-laboratory test materials and as laboratory reference materials, for internal quality control, e.g., by control charts. The history of reference material production within the Joint Research Centre is briefly reviewed and the latest additions described. New developments such as micro-scale reference materials intended for analytical methods requiring sample intakes at milligram or sub-milligram level and therefor not finding supply on the reference material market, and "wet" environmental reference materials, which meet more precisely the "real-world" environmental analysis conditions, are presented and the state-of-the-art discussed.
Certification of reference materials for the determination of alkylphenols.
Hanari, Nobuyasu; Ishikawa, Keiichiro; Shimizu, Yoshitaka; Otsuka, Satoko; Iwasawa, Ryoko; Fujiki, Naomi; Numata, Masahiko; Yarita, Takashi; Kato, Kenji
2015-04-01
Certified reference materials (CRMs) are playing an increasingly important role in national and international standardizing activities. In Japan, primary standard solutions for analyses of endocrine disrupters are supplied under the national standards dissemination system named the Japan Calibration Service System (JCSS). For the traceability on reference materials used for preparation of the primary standard solutions based on the JCSS, the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed and certified high-purity reference materials of alkylphenols as NMIJ CRMs, such as 4-n-nonylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-tert-butylphenol, and 2,4-dichlorophenol. Thereafter, it is essential to determine the alkylphenols by using these solutions based on the JCSS for environmental monitoring and risk assessments because analytical values obtained by using the solutions can ensure the reliability and traceability of the chemical analyses.
Bercaru, Ofelia; Gawlik, Bernd Manfred; Ulberth, Franz; Vandecasteele, Carlo
2003-08-01
During recent years, the awareness of quality assurance and quality control in environmental analyses has constantly increased, especially due to the implementation of new guidelines and regulations at both the national and international level. Achieving comparable results by using certified reference materials is one of the primary concerns of the scientific community. As a result, there is a growing demand for certified reference materials to cover different matrices and pollutants. Moreover, these CRMs should be in close relationship to the determinants and target concentrations required by environmental bodies and European Directives as well. Supplementary information to this paper presents an inventory of reference materials available on the market from different suppliers against the priority pollutants listed in the Water Framework Directive. These CRMs cover matrices such as water, sediment and biota. The use of CRMs in relationship to appropriate analytical methods and relevant determinants is discussed and the need for matrix-CRMs, particularly for organic pollutants is emphasised. The use of proficiency testing schemes as an alternative for the lack of appropriate CRMs and future trends in the production of CRMs within the BCR framework are also discussed.
[Development of the certified reference material of mercury in lyophilized human urine].
Zhao, Wei; Zhang, Fu-gang; DU, Hui-fang; Pan, Ya-juan; Yan, Hui-fang
2011-02-01
To develop the certified reference material of mercury in lyophilized human urine. Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L. The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.
Nuclear reference materials to meet the changing needs of the global nuclear community
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, H.R.; Gradle, C.G.; Narayanan, U.I.
New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less
Turk, G C; Yu, L L; Salit, M L; Guthrie, W F
2001-06-01
Multielement analyses of environmental reference materials have been performed using existing certified reference materials (CRMs) as calibration standards for inductively coupled plasma-mass spectrometry. The analyses have been performed using a high-performance methodology that results in comparison measurement uncertainties that are significantly less than the uncertainties of the certified values of the calibration CRM. Consequently, the determined values have uncertainties that are very nearly equivalent to the uncertainties of the calibration CRM. Several uses of this calibration transfer are proposed, including, re-certification measurements of replacement CRMs, establishing traceability of one CRM to another, and demonstrating the equivalence of two CRMs. RM 8704, a river sediment, was analyzed using SRM 2704, Buffalo River Sediment, as the calibration standard. SRM 1632c, Trace Elements in Bituminous Coal, which is a replacement for SRM 1632b, was analyzed using SRM 1632b as the standard. SRM 1635, Trace Elements in Subbituminous Coal, was also analyzed using SRM 1632b as the standard.
Scharf, Holger; Bremser, Wolfram
2015-04-01
Cyanides are among the most important inorganic pollutants to be tested and monitored in environmental compartments. They can be distinguished and determined as free cyanide, weak acid dissociable cyanide or as total cyanide. However, in any case obtained, measurement results are operationally defined referring to the applied analytical method. In 2011, the International Standard ISO 11262 has been published which specifies a normative analytical method for the determination of total cyanide in soil. The objective of the project described in this paper was to provide the first soil reference material (CRM) certified for its mass fraction of total cyanide on the basis of this standard. A total of 12 German laboratories with proven experience in the determination of cyanides in environmental samples participated in the certification study. Measurement results were evaluated in full compliance with the requirements of ISO Guide 35. Taking into account the results of the inter-laboratory comparison as well as the outcome of the homogeneity and stability studies, a certified mass fraction of total cyanide of 21.1 mg/kg and an expanded uncertainty (k = 2) of 1.3 mg/kg were assigned to the material. The reference material has been issued as CRM BAM-U114.
Characterization of NIES CRM No. 23 Tea Leaves II for the determination of multielements.
Mori, Ikuko; Ukachi, Miyuki; Nagano, Kimiyo; Ito, Hiroyasu; Yoshinaga, Jun; Nishikawa, Masataka
2010-05-01
A candidate environmental certified reference material (CRM) for the determination of multielements in tea leaves and materials of similar matrix, NIES CRM No. 23 Tea Leaves II, has been developed and characterized by the National Institute for Environmental Studies (NIES), Japan. The origin of the material was tea leaves, which were ground, sieved through a 106-microm mesh, homogenized, and then subdivided into amber glass bottles. The results of homogeneity and stability tests indicated that the material was sufficiently homogeneous and stable for use as a reference material. The property values of the material were statistically determined based on chemical analyses by a network of laboratories using a wide range of methods. Sixteen laboratories participated in the characterization, and nine certified values and five reference values were obtained. These property values of the candidate CRM, which are expressed as mass fractions, were close to the median and/or mean values of the mass fractions of elements in various tea products. The candidate CRM is appropriate for use in analytical quality control and in the evaluation of methods used in the analysis of tea and materials of similar matrix.
NASA Astrophysics Data System (ADS)
Valotto, Gabrio; Cattaruzza, Elti; Bardelli, Fabrizio
2017-02-01
The appropriate selection of representative pure compounds to be used as reference is a crucial step for successful analysis of X-ray absorption near edge spectroscopy (XANES) data, and it is often not a trivial task. This is particularly true when complex environmental matrices are investigated, being their elemental speciation a priori unknown. In this paper, an investigation on the speciation of Cu, Zn, and Sb based on the use of conventional (stoichiometric compounds) and non-conventional (environmental samples or relevant certified materials) references is explored. This method can be useful in when the effectiveness of XANES analysis is limited because of the difficulty in obtaining a set of references sufficiently representative of the investigated samples. Road dust samples collected along the bridge connecting Venice to the mainland were used to show the potentialities and the limits of this approach.
NASA Astrophysics Data System (ADS)
Murphy, James; Jones, Phil; Hill, Steve J.
1996-12-01
A simple and accurate method has been developed for the determination of total mercury in environmental and biological samples. The method utilises an off-line microwave digestion stage followed by analysis using a flow injection system with detection by cold vapour atomic absorption spectrometry. The method has been validated using two certified reference materials (DORM-1 dogfish and MESS-2 estuarine sediment) and the results agreed well with the certified values. A detection limit of 0.2 ng g -1 Hg was obtained and no significant interference was observed. The method was finally applied to the determination of mercury in river sediments and canned tuna fish, and gave results in the range 0.1-3.0 mg kg -1.
A study of compliance with environmental regulations of ISO 14001 certified companies in Korea.
Kwon, Dong-Myung; Seo, Min-Seok; Seo, Yong-Chil
2002-08-01
This article investigates the impact of ISO 14001 certification on the compliance with environmental regulations by Korean companies. The impact of ISO 14001 certification on the industry was studied through a questionnaire survey and the compliance of environmental regulations were investigated using government-released data. The motivation for an environment management system was a result of the current international situation and the need to maintain fair competition. ISO 14001 certification has been recognized as an essential strategy for industrial competition and to improve company/product recognition. The certified and non-certified companies' environmental regulation violation (ERV) rates were 3.5% and 11.6%, respectively, in 1997. In 1998, the ERV rate had an eight-time difference with 1.0% and 8.5% for certified and non-certified companies, respectively. Annual regulation violation rates were reduced from 3.5% in 1997 to 1.0% in 1998 with certified companies and from 11.6% in 1997 to 8.5% in 1998 with their non-certified counterparts, respectively. ISO 14001 certified companies showed more improvement than non-certified companies in regards to environmental performance.
Valotto, Gabrio; Cattaruzza, Elti; Bardelli, Fabrizio
2017-02-15
The appropriate selection of representative pure compounds to be used as reference is a crucial step for successful analysis of X-ray absorption near edge spectroscopy (XANES) data, and it is often not a trivial task. This is particularly true when complex environmental matrices are investigated, being their elemental speciation a priori unknown. In this paper, an investigation on the speciation of Cu, Zn, and Sb based on the use of conventional (stoichiometric compounds) and non-conventional (environmental samples or relevant certified materials) references is explored. This method can be useful in when the effectiveness of XANES analysis is limited because of the difficulty in obtaining a set of references sufficiently representative of the investigated samples. Road dust samples collected along the bridge connecting Venice to the mainland were used to show the potentialities and the limits of this approach. Copyright © 2016 Elsevier B.V. All rights reserved.
Quality assurance for health and environmental chemistry: 1990
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gautier, M.A.; Gladney, E.S.; Koski, N.L.
1991-10-01
This report documents the continuing quality assurance efforts of the Health and Environmental Chemistry Group (HSE-9) at the Los Alamos National Laboratory. The philosophy, methodology, computing resources, and laboratory information management system used by the quality assurance program to encompass the diversity of analytical chemistry practiced in the group are described. Included in the report are all quality assurance reference materials used, along with their certified or consensus concentrations, and all analytical chemistry quality assurance measurements made by HSE-9 during 1990.
NASA Astrophysics Data System (ADS)
Morales-Muñoz, S.; Luque-García, J. L.; Luque de Castro, M. D.
2003-01-01
Acidified and pressurized hot water is proposed for the continuous leaching of Cd and Pb from plants prior to determination by electrothermal atomic absorption spectrometry. Beech leaves (a certified reference material—CRM 100—where the analytes were not certified) were used for optimizing the method by a multivariate approach. The samples (0.5 g) were subjected to dynamic extraction with water modified with 1% v/v HNO 3 at 250 °C as leachant. A kinetics study was performed in order to know the pattern of the extraction process. The method was validated with a CRM (olive leaves, 062 from the BCR) where the analytes had been certified. The agreement between the certified values and those found using the proposed method demonstrates its usefulness. The repeatability and within-laboratory reproducibility were 3.7 and 2.3% for Cd and 1.04% and 6.3% for Pb, respectively. The precision of the method, together with its efficiency, rapidity, and environmental acceptability, makes it a good alternative for the determination of trace metals in plant material.
Persson, Josefin; Wang, Thanh; Hagberg, Jessika
2018-07-01
The construction of extremely airtight and energy efficient low-energy buildings is achieved by using functional building materials, such as age-resistant plastics, insulation, adhesives, and sealants. Additives such as organophosphate flame retardants (OPFRs) can be added to some of these building materials as flame retardants and plasticizers. Some OPFRs are considered persistent, bioaccumulative and toxic. Therefore, in this pilot study, the occurrence and distribution of nine OPFRs were determined for dust, air, and window wipe samples collected in newly built low-energy preschools with and without environmental certifications. Tris(1,3-dichloroisopropyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP) were detected in all indoor dust samples at concentrations ranging from 0.014 to 10μg/g and 0.0069 to 79μg/g, respectively. Only six OPFRs (predominantly chlorinated OPFRs) were detected in the indoor air. All nine OPFRs were found on the window surfaces and the highest concentrations, which occurred in the reference preschool, were measured for 2-ethylhexyl diphenyl phosphate (EHDPP) (maximum concentration: 1500ng/m 2 ). Interestingly, the OPFR levels in the environmental certified low-energy preschools were lower than those in the reference preschool and the non-certified low-energy preschool, probably attributed to the usage of environmental friendly and low-emitting building materials, interior decorations, and consumer products. Copyright © 2018 Elsevier B.V. All rights reserved.
Bulska, Ewa; Krata, Agnieszka; Kałabun, Mateusz; Wojciechowski, Marcin
2017-03-01
This work focused on the development and validation of methodologies for the accurate determination of mercury in environmental samples and its further application for the preparation and certification of new reference materials (RMs). Two certified RMs ERM-CC580 (inorganic matrix) and ERM-CE464 (organic matrix) were used for the evaluation of digestion conditions assuring the quantitative recovery of mercury. These conditions were then used for the digestion of new candidates for the environmental RMs: bottom sediment (M_2 BotSed), herring tissue (M_3 HerTis), cormorant tissue (M_4 CormTis), and codfish muscle (M_5 CodTis). Cold vapor atomic absorption spectrometry (CV AAS) and inductively coupled plasma mass spectrometry (ICP MS) were used for the measurement of mercury concentration in all RMs. In order to validate and assure the accuracy of results, isotope dilution mass spectrometry (IDMS) was applied as a primary method of measurement, assuring the traceability of obtained values to the SI units: the mole, the kilogram, and the second. Results obtained by IDMS using n( 200 Hg)/n( 202 Hg) ratio, with estimated combined uncertainty, were as follows: (916 ± 41)/[4.5 %] ng g -1 (M_2 BotSed), (236 ± 14)/[5.9 %] ng g -1 (M_3 HerTis), (2252 ± 54)/[2.4 %] ng g -1 (M_4 CormTis), and (303 ± 15)/[4.9 %] ng g -1 (M_CodTis), respectively. Different types of detection techniques and quantification (external calibration, standard addition, isotope dilution) were applied in order to improve the quality of the analytical results. The good agreement (within less than 2.5 %) between obtained results and those derived from the Inter-laboratory Comparison, executed by the Institute of Nuclear Chemistry and Technology (Warsaw, Poland) on the same sample matrices, further validated the analytical procedures developed in this study, as well as the concentration of mercury in all four new RMs. Although the developed protocol enabling the metrological certification of the reference value was exemplified by the determination of mercury in environmental samples, it could be considered as valid for any certification procedure required whenever new certified RMs are introduced.
[The water content reference material of water saturated octanol].
Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Zhanyuan
2011-03-01
The national standards of biofuels specify the technique specification and analytical methods. A water content certified reference material based on the water saturated octanol was developed in order to satisfy the needs of the instrument calibration and the methods validation, assure the accuracy and consistency of results in water content measurements of biofuels. Three analytical methods based on different theories were employed to certify the water content of the reference material, including Karl Fischer coulometric titration, Karl Fischer volumetric titration and quantitative nuclear magnetic resonance. The consistency of coulometric and volumetric titration was achieved through the improvement of methods. The accuracy of the certified result was improved by the introduction of the new method of quantitative nuclear magnetic resonance. Finally, the certified value of reference material is 4.76% with an expanded uncertainty of 0.09%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poster, D.L.; Schantz, M.M.; Parris, R.M.
1995-12-31
Standard reference materials (SRMs) are certified reference materials issued by the National Institute of Standards and Technology (NIST). Natural matrix environmental sample SRMs have been developed the Analytical Chemistry Division to assist in validating measurements for organic contaminants in the environment. Many of these are well characterized for contaminants such as polychlorinated biphenyls (PCBs), chlorinated pesticides, and polycyclic aromatic hydrocarbons (PAHs). SRM 1649, Organics in Urban Dust, is currently available with certified concentrations for 5 PAHs but because of the widespread use of this material in air pollution monitoring programs and to expand the usefulness of this material, the authorsmore » are further characterizing the material for a larger number of PAHs as well as PCBs and chlorinated pesticides. They will also soon issue a diesel particulate extract (SRM 1975) that is well characterized for PAHS, including many nitrogen substituted compounds. In addition to natural matrix materials, solutions useful for calibrating chromatographic detector response factors and retention times, and spiking sample blanks for determination of analyte recoveries, are also available. Solution SRMs currently available contain PCS congeners, chlorinated pesticides, and PAHs. New solution SRMs in preparation will contain additional chlorinated pesticides, PCB congeners (e.g., non-ortho substituted chlorobiphenyls), and perdeuterated PAHs. Recent SRM work will be presented with particular attention on the methods used for determining organic contaminant concentrations in the urban dust material and in the diesel particulate extract.« less
Social and Environmental Impacts of Forest Management Certification in Indonesia
Miteva, Daniela A.; Loucks, Colby J.; Pattanayak, Subhrendu K.
2015-01-01
In response to unsustainable timber production in tropical forest concessions, voluntary forest management certification programs such as the Forest Stewardship Council (FSC) have been introduced to improve environmental, social, and economic performance over existing management practices. However, despite the proliferation of forest certification over the past two decades, few studies have evaluated its effectiveness. Using temporally and spatially explicit village-level data on environmental and socio-economic indicators in Kalimantan (Indonesia), we evaluate the performance of the FSC-certified timber concessions compared to non-certified logging concessions. Employing triple difference matching estimators, we find that between 2000 and 2008 FSC reduced aggregate deforestation by 5 percentage points and the incidence of air pollution by 31%. It had no statistically significant impacts on fire incidence or core areas, but increased forest perforation by 4 km2 on average. In addition, we find that FSC reduced firewood dependence (by 33%), respiratory infections (by 32%) and malnutrition (by 1 person) on average. By conducting a rigorous statistical evaluation of FSC certification in a biodiversity hotspot such as Indonesia, we provide a reference point and offer methodological and data lessons that could aid the design of ongoing and future evaluations of a potentially critical conservation policy. PMID:26132491
40 CFR 158.350 - Certified limits.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Certified limits. 158.350 Section 158.350 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.350 Certified limits. The applicant must propose certified...
40 CFR 158.350 - Certified limits.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Certified limits. 158.350 Section 158.350 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.350 Certified limits. The applicant must propose certified...
40 CFR 158.350 - Certified limits.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Certified limits. 158.350 Section 158.350 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.350 Certified limits. The applicant must propose certified...
40 CFR 158.350 - Certified limits.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Certified limits. 158.350 Section 158.350 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.350 Certified limits. The applicant must propose certified...
40 CFR 158.350 - Certified limits.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Certified limits. 158.350 Section 158.350 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.350 Certified limits. The applicant must propose certified...
Rolison, John M.; Treinen, Kerri C.; McHugh, Kelly C.; ...
2017-11-06
Uranium certified reference materials (CRM) issued by New Brunswick Laboratory were subjected to dating using four independent uranium-series radiochronometers. In all cases, there was acceptable agreement between the model ages calculated using the 231Pa– 235U, 230Th– 234U, 227Ac– 235U or 226Ra– 234U radiochronometers and either the certified 230Th– 234U model date (CRM 125-A and CRM U630), or the known purification date (CRM U050 and CRM U100). Finally, the agreement between the four independent radiochronometers establishes these uranium certified reference materials as ideal informal standards for validating dating techniques utilized in nuclear forensic investigations in the absence of standards with certifiedmore » model ages for multiple radiochronometers.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rolison, John M.; Treinen, Kerri C.; McHugh, Kelly C.
Uranium certified reference materials (CRM) issued by New Brunswick Laboratory were subjected to dating using four independent uranium-series radiochronometers. In all cases, there was acceptable agreement between the model ages calculated using the 231Pa– 235U, 230Th– 234U, 227Ac– 235U or 226Ra– 234U radiochronometers and either the certified 230Th– 234U model date (CRM 125-A and CRM U630), or the known purification date (CRM U050 and CRM U100). Finally, the agreement between the four independent radiochronometers establishes these uranium certified reference materials as ideal informal standards for validating dating techniques utilized in nuclear forensic investigations in the absence of standards with certifiedmore » model ages for multiple radiochronometers.« less
Development of benzene, toluene, ethylbenzene and xylenes certified gaseous reference materials
NASA Astrophysics Data System (ADS)
Brum, M. C.; Sobrinho, D. C. G.; Fagundes, F. A.; Oudwater, R. J.; Augusto, C. R.
2016-07-01
The work describes the production of certified gaseous reference materials of benzene, toluene, ethylbenzene and xylenes (BTEX) in nitrogen from the gravimetric production up to the long term stability tests followed by the certifying step. The uncertainty in the amount fractions of the compounds in these mixtures was approximately 4% (relative) for the range studied from 2 to 16 µmol/mol. Also the adsorption of the BTEX on the cylinder surface and the tubing were investigated as potential uncertainty source.
Kim, Sang-Bog; Roche, Jennifer
2013-08-01
Organically bound tritium (OBT) is an important tritium species that can be measured in most environmental samples, but has only recently been recognized as a species of tritium in these samples. Currently, OBT is not routinely measured by environmental monitoring laboratories around the world. There are no certified reference materials (CRMs) for environmental samples. Thus, quality assurance (QA), or verification of the accuracy of the OBT measurement, is not possible. Alternatively, quality control (QC), or verification of the precision of the OBT measurement, can be achieved. In the past, there have been differences in OBT analysis results between environmental laboratories. A possible reason for the discrepancies may be differences in analytical methods. Therefore, inter-laboratory OBT comparisons among the environmental laboratories are important and would provide a good opportunity for adopting a reference OBT analytical procedure. Due to the analytical issues, only limited information is available on OBT measurement. Previously conducted OBT inter-laboratory practices are reviewed and the findings are described. Based on our experiences, a few considerations were suggested for the international OBT inter-laboratory comparison exercise to be completed in the near future. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
This procedure includes the specifications and requirements that must be followed by gas manufacturers during the preparation of compressed cylinder gas Certified Reference Materials (CRM). A CRM is a certified gas standard prepared at a concentration that does not exceed + or - ...
Chiu, C H; Turle, R; Poole, G; Thibert, B; Brubaker, W W; Schantz, M M; Wise, S A
2001-02-01
Due to the limited number of environmental matrix certified reference materials (CRMs) with assigned values for natural levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), an interlaboratory study was undertaken by the National Institute of Standards and Technology (NIST) and Environment Canada to establish reference concentration values for selected PCDD/Fs in two well-characterized NIST Standard Reference Materials (SRMs): SRM 1649a (Urban Dust) and SRM 1944 (New York/New Jersey Waterway Sediment). Results from 14 laboratories were used to provide reference values for the seventeen 2, 3, 7, 8-substituted PCDD/F congeners, the totals for individual tetra- through hepta-substituted PCDD/F homologues, and the total amount of tetra- through hepta-substituted PCDD/Fs. The mass fractions for the individual 2, 3, 7, 8-substituted congeners range from approximately 0.01 microg/kg to 7 microg/kg dry mass.
Tutschku, S; Schantz, M M; Horvat, M; Logar, M; Akagi, H; Emons, H; Levenson, M; Wise, S A
2001-02-01
The methylmercury content in two new marine bivalve mollusk tissue Standard Reference Materials (SRMs) has been certified using results of analyses from the National Institute of Standards and Technology (NIST) and two other laboratories. The certified concentrations of methylmercury were established based on the results from four and six different (independent) analytical methods, respectively, for SRM 1566b Oyster Tissue (13.2 +/- 0.7 microg/kg) and SRM 2977 Mussel Tissue (organic contaminants and trace elements) (36.2 +/- 1.7 microg/kg). The certified concentration of methylmercury in SRM 1566b is among the lowest in any certified reference material (CRM).
Energy Consumption Evaluation of United States Navy Leed Certified Building For Fiscal Year 2009
2010-01-01
administration functions, classroom training, laboratory functions, personnel detention, and a fully functioning dog kennel on the exterior of the...Leadership in Energy and Environmental Design (LEED) Silver certified by the United States Green Building Council (USGBC). The goal of this effort is in...and Environmental Design (LEED) Silver certified by the United States Green Building Council (USGBC). The goal of this effort is in compliance with
Duan, Jiankuan; Hu, Bin; He, Man
2012-10-01
In this paper, a new method of nanometer-sized alumina packed microcolumn SPE combined with field-amplified sample stacking (FASS)-CE-UV detection was developed for the speciation analysis of inorganic selenium in environmental water samples. Self-synthesized nanometer-sized alumina was packed in a microcolumn as the SPE adsorbent to retain Se(IV) and Se(VI) simultaneously at pH 6 and the retained inorganic selenium was eluted by concentrated ammonia. The eluent was used for FASS-CE-UV analysis after NH₃ evaporation. The factors affecting the preconcentration of both Se(IV) and Se(VI) by SPE and FASS were studied and the optimal CE separation conditions for Se(IV) and Se(VI) were obtained. Under the optimal conditions, the LODs of 57 ng L⁻¹ (Se(IV)) and 71 ng L⁻¹ (Se(VI)) were obtained, respectively. The developed method was validated by the analysis of a certified reference material of GBW(E)080395 environmental water and the determined value was in a good agreement with the certified value. It was also successfully applied to the speciation analysis of inorganic selenium in environmental water samples, including Yangtze River water, spring water, and tap water. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Virginia Finley; Sheneman, Robert S.; Levine, Jerry D.
Contained in the following report are data for radioactivity in the environment collected and analyzed by Princeton Plasma Physics Laboratory’s Princeton Environmental, Analytical, and Radiological Laboratory (PEARL). The PEARL is located on-site and is certified for analyzing radiological and non-radiological parameters through the New Jersey Department of Environmental Protection’s Laboratory Certification Program, Certification Number 12471. Non-radiological surface and ground water samples are analyzed by NJDEP certified subcontractor laboratories – QC, Inc. and Accutest Laboratory. To the best of our knowledge, these data, as contained in the “Annual Site Environmental Report for 2011,” are documented and certified to be correct.
40 CFR 141.28 - Certified laboratories.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 141.28 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Monitoring and Analytical Requirements § 141.28 Certified... certified by the State except that measurements of alkalinity, calcium, conductivity, disinfectant residual...
40 CFR 141.28 - Certified laboratories.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 141.28 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Monitoring and Analytical Requirements § 141.28 Certified... certified by the State except that measurements of alkalinity, calcium, conductivity, disinfectant residual...
Selliah, S S; Cussion, S; MacPherson, K A; Reiner, E J; Toner, D
2001-06-01
Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.
24 CFR 58.13 - Responsibilities of the certifying officer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Responsibilities of the certifying officer. 58.13 Section 58.13 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development ENVIRONMENTAL REVIEW PROCEDURES FOR ENTITIES ASSUMING HUD ENVIRONMENTAL...
Development of certified environmental management in hospital and outpatient haemodialysis units.
García Vicente, Sergio; Morales Suárez-Varela, María; Martí Monrós, Anna; Llopis González, Agustín
2015-01-01
The environmental impact of haemodialysis is very high. Institutional activity in this sense is important, even in the production of references. Voluntary environmental management systems (EMS), environmental management and auditing systems (EMAS) and the International Organization for Standardization standards (ISO 14001) are important tools for environmental protection, together with legislation, taxation and tax benefits. To determine the degree of implementation of EMS in hospital units and outpatient haemodialysis in the Spanish National Health System to provide a group of reference centres in environmental management in this healthcare activity. Development of a list by autonomous communities showing hospital and outpatient dialysis units using an EMAS and/or ISO 14001 in 2012-2013. The sources of information were the Spanish National Catalogue of Hospitals, Spanish Registry of Healthcare Certification and Accreditation, European and regional EMAS records, world ISO registrations, dialysis centre lists from scientific societies and patients, responses from accredited entities in Spain for environmental certification and the institutional website of each haemodialysis centre identified. Of the 210 hospitals with a dialysis unit, 53 (25%) have the ISO 14001 and 15 of these also have an EMAS). This constitutes 30% of all hospital dialysis chairs in Spain: 1,291 (of 4,298). Only 11 outpatient clinics are recorded, all with the ISO 14001. There is no official documentation of the implementation of EMS in dialysis units. Making this list provides an approach to the situation, with special reference to haemodialysis because of its significant environmental impact. Copyright © 2015 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.
Rigger, Romana; Rück, Alexander; Hellriegel, Christine; Sauermoser, Robert; Morf, Fabienne; Breitruck, KathrinBreitruck; Obkircher, Markus
2017-09-01
In recent years, quantitative NMR (qNMR) spectroscopy has become one of the most important tools for content determination of organic substances and quantitative evaluation of impurities. Using Certified Reference Materials (CRMs) as internal or external standards, the extensively used qNMR method can be applied for purity determination, including unbroken traceability to the International System of Units (SI). The implementation of qNMR toward new application fields, e.g., metabolomics, environmental analysis, and physiological pathway studies, brings along more complex molecules and systems, thus making use of 1H qNMR challenging. A smart workaround is possible by the use of other NMR active nuclei, namely 31P and 19F. This article presents the development of three classes of qNMR CRMs based on different NMR active nuclei (1H, 31P, and 19F), and the corresponding approaches to establish traceability to the SI through primary CRMs from the National Institute of Standards and Technology and the National Metrology Institute of Japan. These TraceCERT® qNMR CRMs are produced under ISO/IEC 17025 and ISO Guide 34 using high-performance qNMR.
Chew, Gina; Sim, Lay Peng; Ng, Sin Yee; Ding, Yi; Shin, Richard Y C; Lee, Tong Kooi
2016-01-01
Isotope dilution mass spectrometry and standard addition techniques were developed for the analysis of four elements (Ca, As, Cd and Pb) in a mushroom powder material. Results from the validated methods were compared to those of other national metrology institutes in the CCQM-K89 intercomparisons and the results were in excellent agreement with the reference values. The same methods were then used for the assignment of reference values to a mushroom powder Certified Reference Material (CRM). The certified values obtained for Ca, As, Cd and Pb were 1.444 ± 0.099 mg/g, 5.61 ± 0.59 mg/kg, 1.191 ± 0.079 mg/kg and 5.23 ± 0.94 mg/kg, respectively. The expanded measurement uncertainties were obtained by combining the uncertainty contributions from characterization (uchar) and between-bottle homogeneity (ubb). Copyright © 2015 Elsevier Ltd. All rights reserved.
40 CFR 124.53 - State certification.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., or waived its right to certify; and (3) A statement that the State will be deemed to have waived its right to certify unless that right is exercised within a specified reasonable time not to exceed 60 days... each more stringent condition, the certifying State agency shall cite the CWA or State law references...
Development of a Certified Reference Material (NMIJ CRM 7203-a) for Elemental Analysis of Tap Water.
Zhu, Yanbei; Narukawa, Tomohiro; Inagaki, Kazumi; Miyashita, Shin-Ichi; Kuroiwa, Takayoshi; Ariga, Tomoko; Kudo, Izumi; Koguchi, Masae; Heo, Sung Woo; Suh, Jung Ki; Lee, Kyoung-Seok; Yim, Yong-Hyeon; Lim, Youngran
2017-01-01
A certified reference material (CRM), NMIJ CRM 7203-a, was developed for the elemental analysis of tap water. At least two independent analytical methods were applied to characterize the certified value of each element. The elements certified in the present CRM were as follows: Al, As, B, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Rb, Sb, Se, Sr, and Zn. The certified value for each element was given as the (property value ± expanded uncertainty), with a coverage factor of 2 for the expanded uncertainty. The expanded uncertainties were estimated while considering the contribution of the analytical methods, the method-to-method variance, the sample homogeneity, the long-term stability, and the concentrations of the standard solutions for calibration. The concentration of Hg (0.39 μg kg -1 ) was given as the information value, since loss of Hg was observed when the sample was stored at room temperature and exposed to light. The certified values of selected elements were confirmed by a co-analysis carried out independently by the NMIJ (Japan) and the KRISS (Korea).
Boulyga, Sergei F; Heumann, Klaus G
2005-10-01
Laser ablation inductively coupled plasma isotope dilution mass spectrometry (LA-ICP-IDMS) was applied to the direct and simultaneous determination of the platinum group elements (PGEs) Pt, Pd, Ru, and Ir in geological and environmental samples. A special laser ablation system with high ablation rates was used, along with sector field ICP-MS. Special attention was paid to deriving the distributions of PGEs in the pulverized samples. IDMS could not be applied to the (mono-isotopic) Rh, but the similar ablation behavior of Ru and Rh allowed Rh to be simultaneously determined via relative sensitivity coefficients. The laser ablation process produces hardly any oxide ions (which usually cause interference in PGE analysis with liquid sample injection), so the ICP-MS can be run in its low mass resolution but high-sensitivity mode. The detection limits obtained for the geological samples were 0.16 ng g(-1), 0.14 ng g(-1), 0.08 ng g(-1), 0.01 ng g(-1) and 0.06 ng g(-1) for Ru, Rh, Pd, Ir and Pt, respectively. LA-ICP-IDMS was applied to different geological reference materials (TDB-1, WGB-1, UMT-1, WMG-1, SARM-7) and the road dust reference material BCR-723, which are only certified for some of the PGEs. Comparisons with certified values as well as with indicative values from the literature demonstrated the validity of the LA-ICP-IDMS method. The PGE concentrations in subsamples of the road dust reference material correspond to a normal distribution, whereas the distributions in the geological reference materials TDB-1, WGB-1, UMT-1, WMG-1, and SARM-7 are more complex. For example, in the case of Ru, a logarithmic normal distribution best fits the analyzed concentrations in TDB-1 subsamples, whereas a pronounced nugget effect was found for Pt in most geological samples.
Certified reference materials (GBW09170 and 09171) of creatinine in human serum.
Dai, Xinhua; Fang, Xiang; Shao, Mingwu; Li, Ming; Huang, Zejian; Li, Hongmei; Jiang, You; Song, Dewei; He, Yajuan
2011-02-15
Creatinine is the most widely used clinical marker for assessing renal function. Concentrations of creatinine in human serum need to be carefully checked in order to ensure accurate diagnosis of renal function. Therefore, development of certified reference materials (CRMs) of creatinine in serum is of increasing importance. In this study, two new CRMs (Nos. GBW09170 and 09171) for creatinine in human serum have been developed. They were prepared with mixtures of several dozens of healthy people's and kidney disease patient's serum, respectively. The certified values of 8.10, 34.1 mg/kg for these two CRMs have been assigned by liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) method which was validated by using standard reference material (SRM) of SRM909b (a reference material obtained from National Institute of Standards and Technology, NIST). The expanded uncertainties of certified values for low and high concentrations were estimated to be 1.2 and 1.1%, respectively. The certified values were further confirmed by an international intercomparison for the determination of creatinine in human serum (Consultative Committee for Amount of Substance, CCQM) of K80 (CCQM-K80). These new CRMs of creatinine in human serum pool are totally native without additional creatinine spiked for enrichment. These new CRMs are capable of validating routine clinical methods for ensuring accuracy, reliability and comparability of analytical results from different clinical laboratories. They can also be used for instrument validation, development of secondary reference materials, and evaluating the accuracy of high order clinical methods for the determination of creatinine in human serum. Copyright © 2011 Elsevier B.V. All rights reserved.
40 CFR 80.1611 - Standards and requirements for certified ethanol denaturant.
Code of Federal Regulations, 2014 CFR
2014-07-01
... certified ethanol denaturant. 80.1611 Section 80.1611 Protection of Environment ENVIRONMENTAL PROTECTION....1611 Standards and requirements for certified ethanol denaturant. Producers and importers of ethanol denaturant that is suitable for the manufacture of denatured fuel ethanol (DFE) meeting federal quality...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olson, John; Adamic, Mary; Snyder, Darin
Iodine environmental measurements have consistently been backed up in the literature by standard materials like IAEA-375, Chernobyl Soil. There are not many other sources of a certified reference material for 129I content for mass spectrometry measurements. Some that have been found in the literature include NIST-4354 and NIST-4357. They are still available at the time of this writing. They don’t have certified content or isotopic values. There has been some work in the literature to show that iodine is present, but there hasn’t been enough to establish a consensus value. These materials have been analyzed at INL through two separatemore » mass spectrometry techniques. They involve a combustion method of the starting material in oxygen, followed by TIMS analysis and a leaching preparation analyzed by accelerator mass spectrometry. Combustion/TIMS preparation of NIST SRM-4354 resulted in a 129I/127I ratio of 1.92 x 10-6 which agrees with AMS measurements which measured the 129I/127I ratio to be 1.93 x 10-6.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hult, Erin L.; Willem, Henry; Price, Phillip N.
2014-10-01
Measurements were taken in new US residences to assess the extent to which ventilation and source control can mitigate formaldehyde exposure. Increasing ventilation consistently lowered indoor formaldehyde concentrations. However, at a reference air exchange rate of 0.35 h -1, increasing ventilation was up to 60% less effective than would be predicted if the emission rate were constant. This is consistent with formaldehyde emission rates decreasing as air concentrations increase, as observed in chamber studies. In contrast, measurements suggest acetaldehyde emission was independent of ventilation rate. To evaluate the effectiveness of source control, formaldehyde concentrations were measured in Leadership in Energymore » and Environmental Design (LEED) certified/Indoor airPLUS homes constructed with materials certified to have low emission rates of volatile organic compounds (VOC). At a reference air exchange rate of 0.35 h -1, and adjusting for home age, temperature and relative humidity, formaldehyde concentrations in homes built with low-VOC materials were 42% lower on average than in reference new homes with conventional building materials. Without adjustment, concentrations were 27% lower in the low-VOC homes. The mean and standard deviation of formaldehyde concentration were 33 μg m-3 and 22 μg m -3 for low-VOC homes and 45 μg m -3 and 30 μg m -3 for conventional.« less
Nhu, Trang T; Schaubroeck, Thomas; Henriksson, Patrik J G; Bosma, Roel; Sorgeloos, Patrick; Dewulf, Jo
2016-12-01
Pangasius production in Vietnam is widely known as a success story in aquaculture, the fastest growing global food system because of its tremendous expansion by volume, value and the number of international markets to which Pangasius has been exported in recent years. While certification schemes are becoming significant features of international fish trade and marketing, an increasing number of Pangasius producers have followed at least one of the certification schemes recognised by international markets to incorporate environmental and social sustainability practices in aquaculture, typically the Pangasius Aquaculture Dialogue (PAD) scheme certified by the Aquaculture Stewardship Council (ASC). An assessment of the environmental benefit of applying certification schemes on Pangasius production, however, is still needed. This article compared the environmental impact of ASC-certified versus non-ASC certified intensive Pangasius aquaculture, using a statistically supported LCA. We focused on both resource-related (water, land and total resources) and emissions-related (global warming, acidification, freshwater and marine eutrophication) categories. The ASC certification scheme was shown to be a good approach for determining adequate environmental sustainability, especially concerning emissions-related categories, in Pangasius production. However, the non-ASC certified farms, due to the large spread, the impact (e.g., water resources and freshwater eutrophication) was possibly lower for a certain farm. However, this result was not generally prominent. Further improvements in intensive Pangasius production to inspire certification schemes are proposed, e.g., making the implementation of certification schemes more affordable, well-oriented and facilitated; reducing consumed feed amounts and of the incorporated share in fishmeal, especially domestic fishmeal, etc. However, their implementation should be vetted with key stakeholders to assess their feasibility. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhao, Bingshan; He, Man; Chen, Beibei; Hu, Bin
2015-05-01
Determination of trace Cd in environmental, biological and food samples is of great significance to toxicological research and environmental pollution monitoring. While the direct determination of Cd in real-world samples is difficult due to its low concentration and the complex matrix. Herein, a novel Cd(II)-ion imprinted magnetic mesoporous silica (Cd(II)-II-MMS) was prepared and was employed as a selective magnetic solid-phase extraction (MSPE) material for extraction of trace Cd in real-world samples followed by graphite furnace atomic absorption spectrometry (GFAAS) detection. Under the optimized conditions, the detection limit of the proposed method was 6.1 ng L- 1 for Cd with the relative standard deviation (RSD) of 4.0% (c = 50 ng L- 1, n = 7), and the enrichment factor was 50-fold. To validate the proposed method, Certified Reference Materials of GSBZ 50009-88 environmental water, ZK018-1 lyophilized human urine and NIES10-b rice flour were analyzed and the determined values were in a good agreement with the certified values. The proposed method exhibited a robust anti-interference ability due to the good selectivity of Cd(II)-II-MMS toward Cd(II). It was successfully employed for the determination of trace Cd(II) in environmental water, human urine and rice samples with recoveries of 89.3-116%, demonstrating that the proposed method has good application potential in real world samples with complex matrix.
10 CFR 504.9 - Environmental requirements for certifying powerplants.
Code of Federal Regulations, 2011 CFR
2011-01-01
....9 Section 504.9 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS EXISTING POWERPLANTS § 504.9... use of natural gas or petroleum, or both, as a primary energy source in any certifying powerplant... fuel as a primary energy source in a certifying powerplant. (a) NEPA compliance. Except as provided in...
10 CFR 504.9 - Environmental requirements for certifying powerplants.
Code of Federal Regulations, 2013 CFR
2013-01-01
....9 Section 504.9 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS EXISTING POWERPLANTS § 504.9... use of natural gas or petroleum, or both, as a primary energy source in any certifying powerplant... fuel as a primary energy source in a certifying powerplant. (a) NEPA compliance. Except as provided in...
10 CFR 504.9 - Environmental requirements for certifying powerplants.
Code of Federal Regulations, 2014 CFR
2014-01-01
....9 Section 504.9 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS EXISTING POWERPLANTS § 504.9... use of natural gas or petroleum, or both, as a primary energy source in any certifying powerplant... fuel as a primary energy source in a certifying powerplant. (a) NEPA compliance. Except as provided in...
10 CFR 504.9 - Environmental requirements for certifying powerplants.
Code of Federal Regulations, 2012 CFR
2012-01-01
....9 Section 504.9 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS EXISTING POWERPLANTS § 504.9... use of natural gas or petroleum, or both, as a primary energy source in any certifying powerplant... fuel as a primary energy source in a certifying powerplant. (a) NEPA compliance. Except as provided in...
Yang, Dezhi; Wang, Fengfeng; Zhang, Li; Gong, Ningbo; Lv, Yang
2015-05-01
This study compares the results of three certified methods, namely differential scanning calorimetry (DSC), the mass balance (MB) method and coulometric titrimetry (CT), in the purity assessment of ferulic acid certified reference material (CRM). Purity and expanded uncertainty as determined by the three methods were respectively 99.81%, 0.16%; 99.79%, 0.16%; and 99.81%, 0.26% with, in all cases, a coverage factor (k) of 2 (P=95%). The purity results are consistent indicating that the combination of DSC, the MB method and CT provides a confident assessment of the purity of suitable CRMs like ferulic acid.
ALT-114 and ALT-118 Alternative Approaches to NIST ...
In 2016, US EPA approved two separate alternatives (ALT 114 and ALT 118) for the preparation and certification of Hydrogen Chloride (HCl) and Mercury (Hg) cylinder reference gas standards that can serve as EPA Protocol gases where EPA Protocol are required, but unavailable. The alternatives were necessary due to the unavailability of NIST reference materials (SRM, NTRM, CRM or RGM) or VSL reference materials (VSL PRM or VSL CRM), reference materials identified in EPA’s Green Book as necessary to establish the traceability of EPA protocol gases. ALT 114 and ALT 118 provides a pathway for gas vendors to prepare and certify traceable gas cylinder standards for use in certifying Hg and HCl CEMS. In this presentation, EPA will describe the mechanics and requirements of the performance-based approach, provide an update on the availability of these gas standards and also discuss the potential for producing and certifying gas standards for other compounds using this approach. This presentation discusses the importance of NIST-traceable reference gases relative to regulatory source compliance emissions monitoring. Specifically this presentation discusses 2 new approaches for making necessary reference gases available in the absence of NIST reference materials. Moreover, these approaches provide an alternative approach to rapidly make available new reference gases for additional HAPS regulatory compliance emissions measurement and monitoring.
Murphy, K E; Beary, E S; Rearick, M S; Vocke, R D
2000-10-01
Lead (Pb) and cadmium (Cd) have been determined in six new environmental standard reference materials (SRMs) using isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS). The SRMs are the following: SRM 1944, New York-New Jersey Waterway Sediment, SRMs 2583 and 2584, Trace Elements in Indoor Dust, Nominal 90 mg/kg and 10,000 mg/kg Lead, respectively, SRMs 2586 and 2587, Trace Elements in Soil Containing Lead from Paint, Nominal 500 mg/kg and 3,000 mg/kg Lead, respectively, and SRM 2782, Industrial Sludge. The capabilities of ID ICP-MS for the certification of Pb and Cd in these materials are assessed. Sample preparation and ratio measurement uncertainties have been evaluated. Reproducibility and accuracy of the established procedures are demonstrated by determination of gravimetrically prepared primary standard solutions and by comparison with isotope dilution thermal ionization mass spectrometry (ID TIMS). Material heterogeneity was readily demonstrated to be the dominant source of uncertainty in the certified values.
40 CFR 1048.140 - What are the provisions for certifying Blue Sky Series engines?
Code of Federal Regulations, 2012 CFR
2012-07-01
... Blue Sky Series engines? 1048.140 Section 1048.140 Protection of Environment ENVIRONMENTAL PROTECTION... ENGINES Emission Standards and Related Requirements § 1048.140 What are the provisions for certifying Blue... emission control for engines designated as “Blue Sky Series” engines. If you certify an engine family under...
40 CFR 1048.140 - What are the provisions for certifying Blue Sky Series engines?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Blue Sky Series engines? 1048.140 Section 1048.140 Protection of Environment ENVIRONMENTAL PROTECTION... ENGINES Emission Standards and Related Requirements § 1048.140 What are the provisions for certifying Blue... emission control for engines designated as “Blue Sky Series” engines. If you certify an engine family under...
40 CFR 1048.140 - What are the provisions for certifying Blue Sky Series engines?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Blue Sky Series engines? 1048.140 Section 1048.140 Protection of Environment ENVIRONMENTAL PROTECTION... ENGINES Emission Standards and Related Requirements § 1048.140 What are the provisions for certifying Blue... emission control for engines designated as “Blue Sky Series” engines. If you certify an engine family under...
40 CFR 1048.140 - What are the provisions for certifying Blue Sky Series engines?
Code of Federal Regulations, 2013 CFR
2013-07-01
... Blue Sky Series engines? 1048.140 Section 1048.140 Protection of Environment ENVIRONMENTAL PROTECTION... ENGINES Emission Standards and Related Requirements § 1048.140 What are the provisions for certifying Blue... emission control for engines designated as “Blue Sky Series” engines. If you certify an engine family under...
40 CFR 1048.140 - What are the provisions for certifying Blue Sky Series engines?
Code of Federal Regulations, 2014 CFR
2014-07-01
... Blue Sky Series engines? 1048.140 Section 1048.140 Protection of Environment ENVIRONMENTAL PROTECTION... ENGINES Emission Standards and Related Requirements § 1048.140 What are the provisions for certifying Blue... emission control for engines designated as “Blue Sky Series” engines. If you certify an engine family under...
Poster, Dianne L; Kucklick, John R; Schantz, Michele M; Porter, Barbara J; Leigh, Stefan D; Wise, Stephen A
2003-01-01
The concentrations of a wide range of polychlorinated biphenyl congeners (PCBs) and chlorinated pesticides in a fish tissue Standard Reference Material (SRM) have been determined using multiple methods of analysis. This material, SRM 1946, Lake Superior Fish Tissue, was recently issued by the National Institute of Standards and Technology (NIST) and complements a suite of marine environmental natural-matrix SRMs that are currently available from NIST for the determination of organic contaminants such as aliphatic hydrocarbons, polycyclic aromatic hydrocarbons (PAHs), PCBs, and chlorinated pesticides. SRM 1946 is a fresh tissue homogenate (frozen) prepared from filleted adult lake trout (Salvelinus namaycush namaycush) collected from the Apostle Islands region of Lake Superior. SRM 1946 has certified and reference concentrations for PCB congeners, including the three non- ortho PCB congeners, and chlorinated pesticides. Certified concentrations are available for 30 PCB congeners and 15 chlorinated pesticides. Reference concentrations are available for 12 PCB congeners and 2 chlorinated pesticides. In addition, SRM 1946 is characterized for additional chemical constituents and properties: fatty acids, extractable fat, methylmercury, total mercury, selected trace elements, proximates, and caloric content. The characterization of chlorinated compounds is described in this paper with an emphasis on the approach used for the certification of the concentrations of PCB congeners and chlorinated pesticides. The PCB congener and chlorinated pesticide data are also compared to concentrations in other marine natural-matrix reference materials available from NIST (fish oil, mussel tissue, whale blubber, and a second fresh frozen fish tissue homogenate prepared from filleted adult lake trout collected from Lake Michigan) and from other organizations such as the National Research Council Canada (ground whole carp), the International Atomic Energy Agency (fish homogenate), and the European Commission Joint Research Centre [fish oils (cod and mackerel) and mussel tissue].
Green Power Equivalency Calculator - Calculations and References
Green power products eligible to be certified by an independent third party against national standards. As a matter of best practice and consumer protection, EPA strongly encourages organizations to purchase these types of certified green power products.
Analysis of Data in Accordance with Space Flight Mission Environmental Requirements
NASA Technical Reports Server (NTRS)
Shei, Monica
2011-01-01
The Environmental Assurance Program sets forth standards to ensure that all flight hardware is compatible with the environments that will be encountered during a spacecraft mission. It outlines the design, test and analysis, and risk control standards for the mission and certifies that it will survive in any external or self-induced environments that the spacecraft may experience. The Environmental Requirements Document (ERD) is the most important document in the Environmental Assurance Program, providing the design and test requirements for the project's flight system, subsystems, assemblies, and instruments. This summer's project was to assist Environmental Requirements Engineers (ERE's) in completing the Environmental Assurance Program Summary Report for both the Juno Project and Mars Science Laboratory (MSL) Project. The Summary Report is a document summarizing the environmental tests and analyses of each spacecraft at both the assembly and system level. It compiles a source of all relevant information such as waivers and Problem/Failure Reports (PFRs) into a single report for easy reference of how well the spacecraft met the requirements of the project.
NASA Astrophysics Data System (ADS)
Moreda-Piñeiro, Jorge; Alonso-Rodríguez, Elia; López-Mahía, Purificación; Muniategui-Lorenzo, Soledad; Prada-Rodríguez, Darío; Moreda-Piñeiro, Antonio; Bermejo-Barrera, Adela; Bermejo-Barrera, Pilar
2006-12-01
Rapid leaching procedures by Pressurized Liquid Extraction (PLE) have been developed for As, Cd, Cr, Ni and Pb leaching from environmental matrices (marine sediment and soil samples). The Pressurized Liquid Extraction is completed after 16 min. The released elements by acetic acid Pressurized Liquid Extraction have been evaluated by inductively coupled plasma-optical emission spectrometry. The optimum multi-element leaching conditions when using 5.0 ml stainless steel extraction cells, were: acetic acid concentration 8.0 M, extraction temperature 100 °C, pressure 1500 psi, static time 5 min, flush solvent 60%, two extraction steps and 0.50 g of diatomaceous earth as dispersing agent (diatomaceous earth mass/sample mass ratio of 2). Results have showed that high acetic acid concentrations and high extraction temperatures increase the metal leaching efficiency. Limits of detection (between 0.12 and 0.5 μg g - 1 ) and repeatability of the over-all procedure (around 6.0%) were assessed. Finally, accuracy was studied by analyzing PACS-2 (marine sediment), GBW-07409 (soil), IRANT-12-1-07 (cambisol soil) and IRANT-12-1-08 (luvisol soil) certified reference materials (CRMs). These certified reference materials offer certified concentrations ranges between 2.9 and 26.2 μg g - 1 for As, from 0.068 to 2.85 μg g - 1 for Cd, between 26.4 and 90.7 μg g - 1 for Cr, from 9.3 to 40.0 μg g - 1 for Ni and between 16.3 and 183.0 μg g - 1 for Pb. Recoveries after analysis were between 95.7 and 105.1% for As, 96.2% for Cd, 95.2 and 100.6% for Cr, 95.7 and 103% for Ni and 94.2 and 105.5% for Pb.
The New Chapter of the United States-Indonesia Defense Relations: Reengagement through IMET
2013-06-13
thankful to reference librarians at the Combined Arms Research Library for their assistance in locating all the materials used for this thesis. I am...cooperation which refers to the Leahy Amendment.7 In certifying participation in the IMET program, the Leahy Amendment plays an important role, especially...to certify whether the candidate for the IMET program is free from any human rights violation record. In contrast, the role of Indonesia’s House of
40 CFR 1045.660 - How do I certify outboard or personal watercraft engines for use in jet boats?
Code of Federal Regulations, 2010 CFR
2010-07-01
... watercraft engines for use in jet boats? 1045.660 Section 1045.660 Protection of Environment ENVIRONMENTAL... watercraft engines for use in jet boats? (a) This section describes how to certify outboard or personal watercraft engines for use in jet boats. To be certified under this section, the jet boat engines must be...
40 CFR 1045.660 - How do I certify outboard or personal watercraft engines for use in jet boats?
Code of Federal Regulations, 2011 CFR
2011-07-01
... watercraft engines for use in jet boats? 1045.660 Section 1045.660 Protection of Environment ENVIRONMENTAL... watercraft engines for use in jet boats? (a) This section describes how to certify outboard or personal watercraft engines for use in jet boats. To be certified under this section, the jet boat engines must be...
30 CFR 18.80 - Approval of machines assembled with certified or explosion-proof components.
Code of Federal Regulations, 2014 CFR
2014-07-01
... approved machines will be accepted in lieu of certified components. (b) A single layout drawing (see Figure... approval. A design of the approval plate will accompany the notification of approval. (Refer to §§ 18.10...
Cui, Chao; He, Man; Hu, Bin
2011-03-15
A novel alumina hollow fiber was synthesized by sol-gel template method and was characterized by scanning electron microscopy, N(2) adsorption technique and X-ray diffraction. With the use of prepared alumina hollow fiber as extraction membrane, a new method of flow injection (FI)-membrane solid phase microextraction (MSPME) on-line coupled to inductively coupled plasma-optical emission spectrometry (ICP-OES) was developed for simultaneous determination of trace metals (Cu, Mn and Ni) in environmental water samples. The adsorption capacities of the alumina hollow fiber for Cu, Mn and Ni were found to be 6.6, 8.7 and 13.3 mg g(-1), respectively. With a preconcentration factor of 10, the limits of detection (LODs) for Cu, Mn and Ni were found to be 0.88, 0.61 and 0.38 ng mL(-1), respectively, and the relative standard deviations (RSDs) were ranging from 6.2 to 7.9% (n = 7, c = 10 ng mL(-1)). To validate the accuracy, the proposed method was applied to the analysis of certified reference material GSBZ50009-88 environmental water and the determined values are in good agreement with the certified values. The developed method was also employed for the analysis of Yangtze River water and East Lake water, and the recoveries for the spiked samples were in the range of 87.4-110.2%. Copyright © 2011 Elsevier B.V. All rights reserved.
Shehata, A B; Rizk, M S; Rend, E A
2016-10-01
Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.
Statistical Reference Datasets
National Institute of Standards and Technology Data Gateway
Statistical Reference Datasets (Web, free access) The Statistical Reference Datasets is also supported by the Standard Reference Data Program. The purpose of this project is to improve the accuracy of statistical software by providing reference datasets with certified computational results that enable the objective evaluation of statistical software.
40 CFR 161.175 - Certified limits.
Code of Federal Regulations, 2010 CFR
2010-07-01
... how the certified limits were arrived at (e.g., sample analysis, quantitative estimate based on....175 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR REGISTRATION OF ANTIMICROBIAL PESTICIDES Product Chemistry Data Requirements § 161.175...
Wu, Liqing; Takatsu, Akiko; Park, Sang-Ryoul; Yang, Bin; Yang, Huaxin; Kinumi, Tomoya; Wang, Jing; Bi, Jiaming; Wang, Yang
2015-04-01
This article concerns the development and co-validation of a porcine insulin (pINS) certified reference material (CRM) produced by the National Institute of Metrology, People's Republic of China. Each CRM unit contained about 15 mg of purified solid pINS. The moisture content, amount of ignition residue, molecular mass, and purity of the pINS were measured. Both high-performance liquid chromatography-isotope dilution mass spectrometry and a purity deduction method were used to determine the mass fraction of the pINS. Fifteen units were selected to study the between-bottle homogeneity, and no inhomogeneity was observed. A stability study concluded that the CRM was stable for at least 12 months at -20 °C. The certified value of the CRM was (0.892 ± 0.036) g/g. A co-validation of the CRM was performed among Chinese, Japanese, and Korean laboratories under the framework of the Asian Collaboration on Reference Materials. The co-validation results agreed well with the certified value of the CRM. Consequently, the pINS CRM may be used as a calibration material or as a validation standard for pharmaceutical purposes to improve the quality of pharmaceutical products.
25 CFR 543.3 - How do tribal governments comply with this part?
Code of Federal Regulations, 2010 CFR
2010-04-01
... of a criminal enterprise, terrorism, tax evasion or other unlawful activity. The standards should be...) An independent certified public accountant (CPA) must be engaged to perform “Agreed-Upon Procedures... Certified Public Accountants Inc, (AICPA). SSAE No. 10 at Sections 101 and 201 are incorporated by reference...
40 CFR 161.175 - Certified limits.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Certified limits. 161.175 Section 161.175 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR REGISTRATION OF ANTIMICROBIAL PESTICIDES Product Chemistry Data Requirements § 161.175...
40 CFR 161.175 - Certified limits.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Certified limits. 161.175 Section 161.175 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR REGISTRATION OF ANTIMICROBIAL PESTICIDES Product Chemistry Data Requirements § 161.175...
Zhang, Nan; Suleiman, Jibrin Sabo; He, Man; Hu, Bin
2008-04-15
A new chromium(III)-imprinted 3-(2-aminoethylamino) propyltrimethoxysilane (AAPTS)-functionalized silica gel sorbent was synthesized by a surface imprinting technique and was employed as a selective solid-phase extraction material for speciation analysis of chromium in environmental water samples prior to its determination by inductively coupled plasma mass spectrometry (ICP-MS). The prepared Cr(III)-imprinted silica gel shows the selectivity coefficient of more than 700 for Cr(III) in the presence of Mn(II). The static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Cr(III) were 30.5 mg g(-1) and 13.4 mg g(-1). It was also found that Cr(VI) could be adsorbed at low pH by the prepared imprinted silica gel, and this finding makes it feasible to enrich and determine Cr(VI) at low pH without adding reducing reagents. The imprinted silica gel sorbent offered a fast kinetics for the adsorption and desorption of both chromium species. Under the optimized conditions, the detection limits of 4.43 pg mL(-1) and 8.30 pg mL(-1) with the relative standard deviations (R.S.D.s) of 4.44% and 4.41% (C=0.5 ng mL(-1), n=7) for Cr(III) and Cr(VI) were obtained, respectively. The proposed method was successfully applied to the speciation of trace chromium in environmental water samples. To validate the proposed method, two certified reference materials were analyzed and the determined values were in a good agreement with the certified values. The developed method is rapid, selective, sensitive and applicable for the speciation of trace chromium in environmental water samples.
The importance of reference materials in doping-control analysis.
Mackay, Lindsey G; Kazlauskas, Rymantas
2011-08-01
Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.
Peart, D.B.; Antweiler, Ronald C.; Taylor, Howard E.; Roth, D.A.; Brinton, T.I.
1998-01-01
More than 100 US Geological Survey (USGS) Standard Reference Water Samples (SRWSs) were analyzed for numerous trace constituents, including Al, As, B, Ba, Be, Bi, Br, Cd, Cr, Co, Cu, I, Fe, Pb, Li, Mn, Mo, Ni, Rb, Sb, Se, Sr, Te, Tl, U, V, Zn and major elements (Ca, Mg, Na, SiO2, SO4, Cl) by inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry. In addition, 15 USGS SRWSs and National Institute of Standards and Technology (NIST) standard reference material (SRM) 1641b were analyzed for mercury using cold vapor atomic fluorescence spectrometry. Also USGS SRWS Hg-7 was analyzed using isotope dilution-inductively coupled plasma mass spectrometry. The results were compared with the reported certified values of the following standard reference materials: NIST SRM 1643a, 1643b, 1643c and 1643d and National Research Council of Canada Riverine Water Reference Materials for Trace Metals SLRS-1, SLRS-2 and SLRS-3. New concentration values for trace and major elements in the SRWSs, traceable to the certified standards, are reported. Additional concentration values are reported for elements that were neither previously published for the SRWSs nor traceable to the certified reference materials. Robust statistical procedures were used that were insensitive to outliers. These data can be used for quality assurance/quality control purposes in analytical laboratories.
Development of new reference material neohesperidin for quality control of dietary supplements.
Gong, Ningbo; Zhang, Baoxi; Yang, Dezhi; Gao, Zhaolin; Du, Guanhua; Lu, Yang
2015-07-01
Neohesperidin is an important natural flavanone glycoside distributed in several citrus species. This compound is widely used as a raw material for food additives in the food industry. The request for certified reference materials (CRMs) in dietary supplements was stipulated by the National Administrative Committee for CRMs and was underpinned by the need to improve the accuracy and comparability of measurement data and to establish metrological traceability of analytical results. This paper reports the sample preparation methodology, homogeneity and stability studies, value assignment and uncertainty estimation of a new certified reference material of neohesperidin (GBW09522). Differential scanning calorimetry, coulometric titration and mass balance methods proved to be sufficiently reliable and accurate for certification purposes. The certified value of neohesperidin CRM is 994 g kg(-1) with an expanded uncertainty of 4 g kg(-1) (k = 2). The reference material described above was homogeneous and stable for 12 months at a storage temperature of 25 °C. The new CRM of neohesperidin can be used to validate analytical methods and improve the accuracy of measurement data as well as quality control of neohesperidin-related dietary supplements, foods, traditional herbs and pharmaceutical formulations. © 2014 Society of Chemical Industry.
National Athletic Trainers' Association position statement: environmental cold injuries.
Cappaert, Thomas A; Stone, Jennifer A; Castellani, John W; Krause, Bentley Andrew; Smith, Daniel; Stephens, Bradford A
2008-01-01
To present recommendations for the prevention, recognition, and treatment of environmental cold injuries. Individuals engaged in sport-related or work-related physical activity in cold, wet, or windy conditions are at risk for environmental cold injuries. An understanding of the physiology and pathophysiology, risk management, recognition, and immediate care of environmental cold injuries is an essential skill for certified athletic trainers and other health care providers working with individuals at risk. These recommendations are intended to provide certified athletic trainers and others participating in athletic health care with the specific knowledge and problem-solving skills needed to address environmental cold injuries. Each recommendation has been graded (A, B, or C) according to the Strength of Recommendation Taxonomy criterion scale.
National Athletic Trainers' Association Position Statement: Environmental Cold Injuries
Cappaert, Thomas A; Stone, Jennifer A; Castellani, John W; Krause, Bentley Andrew; Smith, Daniel; Stephens, Bradford A
2008-01-01
Objective: To present recommendations for the prevention, recognition, and treatment of environmental cold injuries. Background: Individuals engaged in sport-related or work-related physical activity in cold, wet, or windy conditions are at risk for environmental cold injuries. An understanding of the physiology and pathophysiology, risk management, recognition, and immediate care of environmental cold injuries is an essential skill for certified athletic trainers and other health care providers working with individuals at risk. Recommendations: These recommendations are intended to provide certified athletic trainers and others participating in athletic health care with the specific knowledge and problem-solving skills needed to address environmental cold injuries. Each recommendation has been graded (A, B, or C) according to the Strength of Recommendation Taxonomy criterion scale. PMID:19030143
Zheng, Chengbin; Sturgeon, Ralph E; Brophy, Christine S; He, Shaopan; Hou, Xiandeng
2010-04-01
A novel approach to the generation of volatile iron compounds (likely the pentacarbonyl) with high efficiency is described, wherein solutions containing either Fe(2+) or Fe(3+) and low molecular weight organic acids such as formic, acetic or propionic are exposed to a UV source. An optimum generation efficiency of 60 +/- 2% was achieved in 50% formic acid at pH 2.5 with an irradiation time of 250 s by use of a 17 W low-pressure mercury grid lamp. Compared to conventional solution nebulization, sensitivity and limit of detection were improved 80- and 100-fold, respectively, at the 238.204 nm Fe II emission line. A precision of 0.75% RSD was achieved at a concentration of 100 ng/mL. Photochemical vapor generation sample introduction was used for the determination of trace iron in several environmental Certified Reference Materials, including National Research Council Canada DORM-3 fish muscle tissue, DOLT-3 and DOLT-4 fish liver tissues, and SLRS-5 river water, providing analytical results in excellent agreement with certified values based on a simple external calibration.
Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M
2010-05-01
Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.
Narukawa, Tomohiro; Inagaki, Kazumi; Zhu, Yanbei; Kuroiwa, Takayoshi; Narushima, Izumi; Chiba, Koichi; Hioki, Akiharu
2012-02-01
A certified reference material, NMIJ CRM 7405-a, for the determination of trace elements and As(V) in algae was developed from the edible marine hijiki (Hizikia fusiforme) and certified by the National Metrology Institute of Japan (NMIJ), the National Institute of Advanced Industrial Science and Technology (AIST). Hijiki was collected from the Pacific coast in the Kanto area of Japan, and was washed, dried, powdered, and homogenized. The hijiki powder was placed in 400 bottles (ca. 20 g each). The concentrations of 18 trace elements and As(V) were determined by two to four independent analytical techniques, including (ID)ICP-(HR)MS, ICP-OES, GFAAS, and HPLC-ICP-MS using calibration solutions prepared from the elemental standard solution of Japan calibration service system (JCSS) and the NMIJ CRM As(V) solution, and whose concentrations are certified and SI traceable. The uncertainties of all the measurements and preparation procedures were evaluated. The values of 18 trace elements and As(V) in the CRM were certified with uncertainty (k = 2).
Quan, Can
2014-06-15
This work described the assignment of purity values to six carbohydrate certified reference materials, including glucose, fructose, galactose, lactose, xylose and sucrose, according to the ISO Guides 34 and 35. The CRMs' purity values were assigned based on the weighted average of quantitative nuclear magnetic resonance method and mass balance approach with high resolution liquid chromatography - evaporative light scattering detection. All the six CRMs with following value amount fractions: glucose (GBW10062) at a certified purity P ± U (k=2) of (0.99 ± 0.005)%; fructose (GBW10063) at (0.99 ± 0.005)%; galactose (GBW10064) at (0.99 ± 0.007)%; lactose (GBW10065) at (0.99 ± 0.008)%; xylose (GBW10066) at (0.99 ± 0.007)% and sucrose (GBW10067) at (0.99 ± 0.008)%, respectively were certified. The homogeneity of the CRMs was determined by an in-house validated liquid chromatographic method. Potential degradation during storage was also investigated and a shelf-life based on this value was established. Copyright © 2013 Elsevier Ltd. All rights reserved.
BCR®-701: a review of 10-years of sequential extraction analyses.
Sutherland, Ross A
2010-11-08
A detailed quantitative analysis was performed on data presented in the literature that focused on the sequential extraction of cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), lead (Pb) and zinc (Zn) from the certified reference material BCR-701 (lake sediment) using the three-step harmonized BCR(®) procedure. The accuracy of data reported in the literature, including precision and different measures of trueness, was assessed relative to the certified values for BCR-701. Forty data sets were accepted following extreme outlier removal, and statistically summarized with measures of central tendency, dispersion, and distribution form. In general, literature data were similar in their measurement precision to the expert laboratories used to certify the trace element contents in BCR-701. The overall median precision for literature reported data was 10% (range 6-19%), compared to certifying laboratories of 9% (range 4-33%). One measure of literature data trueness was assessed via a confirmatory approach using a robust bootstrap method. Only 22% of the comparisons indicated significantly different (all were lower) concentrations reported in the literature compared to certified values. The question of whether the differences are practically significant for environmental studies is raised. Bias was computed as a measure of trueness, and literature data were more frequently negatively biased, indicating lower concentrations reported in the literature for the six trace elements for the three-step sequential procedure compared to the certified values. However, 95% confidence intervals about the average bias for the 18 comparisons indicated only four instances when a mean bias of 0 (i.e., measured=certified) was not incorporated-suggesting statistical difference. Finally, Z-scores incorporating a Horwitz-type function were used to assess the general trueness of laboratory data. Of the 468 laboratory Z-score values computed, 92% were considered to be satisfactory, 5% were questionable, and 3% were unsatisfactory. A detailed examination of the methodology sections of the various studies showed that despite claiming adherence to the harmonized BCR sequential extraction protocol, significant deviations were commonly observed; particularly in moisture correction, sample mass, centrifugation specifics, shaking specifics, and incorporation of filtration. It is likely that failure to strictly adhere to the protocol adversely impacted accuracy, by increasing the degree of imprecision and resulting in more discrepant trueness values. Copyright © 2010 Elsevier B.V. All rights reserved.
Determination of cadmium in sediments by diluted HCI extraction and isotope dilution ICP-MS.
Terán-Baamonde, Javier; Soto-Ferreiro, Rosa-María; Carlosena, Alatzne; Andrade, José-Manuel; Prada, Darío
2018-08-15
Isotope dilution ICP-MS is proposed to measure the mass fraction of Cd extracted by diluted HCl in marine sediments, using a fast and simple extraction procedure based on ultrasonic probe agitation. The 111 Cd isotope was added before the extraction to achieve isotope equilibration with native Cd solubilized from the sample. The parameters affecting trueness and precision of isotope ratio measurements were evaluated carefully and subsequently corrected in order to minimize errors; they were: detector dead time, spectral interferences, mass discrimination factor and optimum sample/spike ratio. The mass fraction of Cd extracted was compared with the sum of the certified contents of the three steps of the sequential extraction procedure of the Standards, Measurements and Testing Programme (SM&T) analysing the BCR 701 sediment to validate the method. The certified and measured values agreed, giving a measured / certified mass fraction ratio of 1.05. Further, the extraction procedure itself was studied by adding the enriched isotope after the extraction step, which allowed verifying that analyte losses occurred during this process. Two additional reference sediments with certified total cadmium contents were also analysed. The method provided very good precision (0.9%, RSD) and a low detection limit, 1.8 ng g -1 . The procedural uncertainty budget was estimated following the EURACHEM Guide by means of the 'GUM Workbench' software, obtaining a relative expanded uncertainty of 1.5%. The procedure was applied to determine the bioaccessible mass fraction of Cd in sediments from two environmentally and economically important areas of Galicia (rias of Arousa and Vigo, NW of Spain). Copyright © 2018 Elsevier B.V. All rights reserved.
Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava
2015-01-01
We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.
Forti, Tatiana; Souto, Aline da S S; do Nascimento, Carlos Roberto S; Nishikawa, Marilia M; Hubner, Marise T W; Sabagh, Fernanda P; Temporal, Rosane Maria; Rodrigues, Janaína M; da Silva, Manuela
2016-01-01
Considering the absence of standards for culture collections and more specifically for biological resource centers in the world, in addition to the absence of certified biological material in Brazil, this study aimed to evaluate a Fungal Collection from Fiocruz, as a producer of certified reference material and as Biological Resource Center (BRC). For this evaluation, a checklist based on the requirements of ABNT ISO GUIA34:2012 correlated with the ABNT NBR ISO/IEC17025:2005, was designed and applied. Complementing the implementation of the checklist, an internal audit was performed. An evaluation of this Collection as a BRC was also conducted following the requirements of the NIT-DICLA-061, the Brazilian internal standard from Inmetro, based on ABNT NBR ISO/IEC 17025:2005, ABNT ISO GUIA 34:2012 and OECD Best Practice Guidelines for BRCs. This was the first time that the NIT DICLA-061 was applied in a culture collection during an internal audit. The assessments enabled the proposal for the adequacy of this Collection to assure the implementation of the management system for their future accreditation by Inmetro as a certified reference material producer as well as its future accreditation as a Biological Resource Center according to the NIT-DICLA-061. Copyright © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.
40 CFR 1036.235 - Testing requirements for certification.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... 1036.235 Section 1036.235 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE HEAVY-DUTY HIGHWAY ENGINES Certifying Engine..., subpart N. Engines certified for use in tractors may also be used in vocational vehicles; however, you may...
40 CFR 1036.235 - Testing requirements for certification.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... 1036.235 Section 1036.235 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE HEAVY-DUTY HIGHWAY ENGINES Certifying Engine..., subpart N. Engines certified for use in tractors may also be used in vocational vehicles; however, you may...
40 CFR 1036.235 - Testing requirements for certification.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... 1036.235 Section 1036.235 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE HEAVY-DUTY HIGHWAY ENGINES Certifying Engine..., subpart N. Engines certified for use in tractors may also be used in vocational vehicles; however, you may...
ERIC Educational Resources Information Center
Szymanski, Edna Mora; And Others
1993-01-01
Investigated human resource development needs of certified rehabilitation counselors (n=1,535). Counselors reported development needs in vocational services; medical/psychosocial aspects; case management/services; and social, cultural, and environmental issues. Significant differences in development needs were found across job levels, job…
40 CFR 85.1407 - Notification of intent to certify.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Notification of intent to certify. 85.1407 Section 85.1407 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Urban Bus Rebuild Requirements § 85.1407...
NASA Astrophysics Data System (ADS)
Kestens, Vikram; Roebben, Gert; Herrmann, Jan; Jämting, Åsa; Coleman, Victoria; Minelli, Caterina; Clifford, Charles; De Temmerman, Pieter-Jan; Mast, Jan; Junjie, Liu; Babick, Frank; Cölfen, Helmut; Emons, Hendrik
2016-06-01
A new certified reference material for quality control of nanoparticle size analysis methods has been developed and produced by the Institute for Reference Materials and Measurements of the European Commission's Joint Research Centre. The material, ERM-FD102, consists of an aqueous suspension of a mixture of silica nanoparticle populations of distinct particle size and origin. The characterisation relied on an interlaboratory comparison study in which 30 laboratories of demonstrated competence participated with a variety of techniques for particle size analysis. After scrutinising the received datasets, certified and indicative values for different method-defined equivalent diameters that are specific for dynamic light scattering (DLS), centrifugal liquid sedimentation (CLS), scanning and transmission electron microscopy (SEM and TEM), atomic force microscopy (AFM), particle tracking analysis (PTA) and asymmetrical-flow field-flow fractionation (AF4) were assigned. The value assignment was a particular challenge because metrological concepts were not always interpreted uniformly across all participating laboratories. This paper presents the main elements and results of the ERM-FD102 characterisation study and discusses in particular the key issues of measurand definition and the estimation of measurement uncertainty.
Preparation and certification of arsenate [As(V)] reference material, NMIJ CRM 7912-a.
Narukawa, Tomohiro; Kuroiwa, Takayoshi; Narushima, Izumi; Jimbo, Yasujiro; Suzuki, Toshihiro; Chiba, Koichi
2010-05-01
Arsenate [As(V)] solution reference material, National Metrology Institute of Japan (NMIJ) certified reference material (CRM) 7912-a, for speciation of arsenic species was developed and certified by NMIJ, the National Institute of Advanced Industrial Science and Technology. High-purity As(2)O(3) reagent powder was dissolved in 0.8 M HNO(3) solution and As(III) was oxidized to As(V) with HNO(3) to prepare 100 mg kg(-1) of As(V) candidate CRM solution. The solution was bottled in 400 bottles (50 mL each). The concentration of As(V) was determined by four independent analytical techniques-inductively coupled plasma mass spectrometry, inductively coupled plasma optical emission spectrometry, graphite furnace atomic absorption spectrometry, and liquid chromatography inductively coupled plasma mass spectrometry-according to As(V) calibration solutions, which were prepared from the arsenic standard of the Japan Calibration Service system and whose species was guaranteed to be As(V) by NMIJ. The uncertainties of all the measurements and preparation procedures were evaluated. The certified value of As(V) in the CRM is (99.53 +/- 1.67) mg kg(-1) (k = 2).
NBL CRM 112-A: A new certified isotopic composition
NASA Astrophysics Data System (ADS)
Thomas, R. B.; Essex, R. M.; Mason, P.
2007-12-01
NBL CRM 112-A Uranium Metal Assay Standard is commonly used as a natural uranium isotopic reference material within the earth science mass spectrometry community. The metal is from the same parent material as NBS SRM 960, the uranyl nitrate solution, CRM 145, and the high-purity uranyl nitrate solution CRM 145-B. Because CRM 112-A has not yet been certified for isotopic composition, it has been assumed that this material has a natural 235U/238U (0.0072527), and the δ234U has been determined by measurement (e.g. -37.1‰; Cheng et al., 2000). These values have been widely used to calibrate the concentration of spikes and standards, and to correct measurements for instrument or mass bias. New, preliminary, isotopic measurements on CRM 145 and CRM 112-A performed at New Brunswick Laboratory suggest that these reference materials have a slightly lower 235U/238U and δ234U than have been commonly used. If this is the case, then data using the accepted values may be slightly biased. The significance of this bias will depend on the uncertainty of the measurement, how the CRM 112-A data is used to correct measurement data, the cited values that were used to correct the data, and the final certified values of the CRM. This fall, New Brunswick Laboratory is certifying the isotopic composition of the CRM 112-A metal using high precision thermal ionization mass spectrometry techniques. Upon completion of certification, the new CRM 112- A standard with certified isotopic ratios will provide the earth science community with a well characterized and traceable reference for calibrating and correcting their mass spectrometry measurement systems.
Pham, M K; van Beek, P; Carvalho, F P; Chamizo, E; Degering, D; Engeler, C; Gascó, C; Gurriaran, R; Hanley, O; Harms, A V; Herrmann, J; Hult, M; Ikeuchi, Y; Ilchmann, C; Kanisch, G; Kis-Benedek, G; Kloster, M; Laubenstein, M; Llaurado, M; Mas, J L; Nakano, M; Nielsen, S P; Osvath, I; Povinec, P P; Rieth, U; Schikowski, J; Smedley, P A; Suplinska, M; Sýkora, I; Tarjan, S; Varga, B; Vasileva, E; Zalewska, T; Zhou, W
2016-03-01
The preparation and characterization of certified reference materials (CRMs) for radionuclide content in sediments collected offshore of Bikini Atoll (IAEA-410) and in the open northwest Pacific Ocean (IAEA-412) are described and the results of the certification process are presented. The certified radionuclides include: (40)K, (210)Pb ((210)Po), (226)Ra, (228)Ra, (228)Th, (232)Th, (234)U, (238)U, (239)Pu, (239+240)Pu and (241)Am for IAEA-410 and (40)K, (137)Cs, (210)Pb ((210)Po), (226)Ra, (228)Ra, (228)Th, (232)Th, (235)U, (238)U, (239)Pu, (240)Pu and (239+240)Pu for IAEA-412. The CRMs can be used for quality assurance and quality control purposes in the analysis of radionuclides in sediments, for development and validation of analytical methods and for staff training. Copyright © 2015 Elsevier Ltd. All rights reserved.
Development of a new chlorogenic acid certified reference material for food and drug analysis.
Yang, Dezhi; Jiao, LingTai; Zhang, Baoxi; Du, Guanhua; Lu, Yang
2017-06-05
This paper reports the preparation and characterization of a new chlorogenic acid (CHA) certified reference material (CRM), which is unavailable commercially. CHA is an active ingredient found in many geo-authentic Chinese medicinal materials and developed as an anti-cancer drug. In this work, trace impurities were isolated and identified through various techniques. CHA CRM was quantified with two analytical methods, and their results were in good agreement with each other. The certified value and corresponding expanded uncertainty of CHA CRM reached 99.4%±0.2%, which was calculated by multiplying the combined standard uncertainty by the coverage factor (k=2), at a confidence level of 95%. This CRM can be used to calibrate measurement system, evaluate or validate measurement procedures, assign traceable property values to non-CRMs, and conduct quality control assays. Copyright © 2017 Elsevier B.V. All rights reserved.
40 CFR 91.1013 - Exemption for certified Small SI engines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... engines. 91.1013 Section 91.1013 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Exclusion and Exemption of Marine SI Engines § 91.1013 Exemption for certified Small SI engines. The provisions of 40 CFR 1045.605...
Boston in Top 25 of EPA’s List of Cities with the Most Energy Star Certified Buildings
The U.S. Environmental Protection Agency (EPA) has announced its tenth annual Top Cities list, which ranks the 25 U.S. metropolitan areas with the most Energy Star certified buildings and superior energy performance in the preceding calendar year.
Molecularly uniform poly(ethylene glycol) certified reference material
NASA Astrophysics Data System (ADS)
Takahashi, Kayori; Matsuyama, Shigetomo; Kinugasa, Shinichi; Ehara, Kensei; Sakurai, Hiromu; Horikawa, Yoshiteru; Kitazawa, Hideaki; Bounoshita, Masao
2015-02-01
A certified reference material (CRM) for poly(ethylene glycol) with no distribution in the degree of polymerization was developed. The degree of polymerization of the CRM was accurately determined to be 23. Supercritical fluid chromatography (SFC) was used to separate the molecularly uniform polymer from a standard commercial sample with wide polydispersity in its degree of polymerization. Through the use of a specific fractionation system coupled with SFC, we are able to obtain samples of poly(ethylene glycol) oligomer with exact degrees of polymerization, as required for a CRM produced by the National Metrology Institute of Japan.
The use of reference materials in quality assurance programmes in food microbiology laboratories.
In't Veld, P H
1998-11-24
Nine different reference materials (RMs) for use in food and water microbiology have been developed with the support of the European Commission (EC). The production process of RMs is based on spray drying bacteria suspended in milk. The highly contaminated milk powder (HCMP) obtained is mixed with sterile milk powder to achieve the desired level of contamination and is subsequently filled into gelatine capsules. The HCMP may need to be stabilised by storage for more than a year before a stable RM can be prepared. The HCMP are mixed with sterile milk powder using a pestle and mortar in order to produce homogeneous RMs. For routine use of RMs Shewhart control charts can be produced. Based on log10 transformed counts, control limits are calculated. Rules for the interpretation of results facilitate the detection of out of control situations. Besides RMs there are also CRMs (Certified Reference Materials) that are certified by the EC Community Bureau of Reference (BCR) and are intended for occasional use. Based on the BCR certificate, user tables are produced presenting the 95% confidence limits for the number of capsules likely to be examined in practice. Also power analysis is made to indicate the minimum difference between the certified value and the observed geometric mean value in relation to the number of capsules examined.
Lu, Xianbo; Chen, Jiping; Wang, Shuqiu; Zou, Lili; Tian, Yuzeng; Ni, Yuwen; Su, Fan
2012-09-01
A method for the preparation and certification of the reference material of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized, packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetrically prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.
Quantitative aspects of inductively coupled plasma mass spectrometry
NASA Astrophysics Data System (ADS)
Bulska, Ewa; Wagner, Barbara
2016-10-01
Accurate determination of elements in various kinds of samples is essential for many areas, including environmental science, medicine, as well as industry. Inductively coupled plasma mass spectrometry (ICP-MS) is a powerful tool enabling multi-elemental analysis of numerous matrices with high sensitivity and good precision. Various calibration approaches can be used to perform accurate quantitative measurements by ICP-MS. They include the use of pure standards, matrix-matched standards, or relevant certified reference materials, assuring traceability of the reported results. This review critically evaluates the advantages and limitations of different calibration approaches, which are used in quantitative analyses by ICP-MS. Examples of such analyses are provided. This article is part of the themed issue 'Quantitative mass spectrometry'.
Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi
2014-01-20
Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV <1%. A certified reference material (CRM) of lipids in frozen human serum was used to verify the accuracy of the measurement. The obtained values for both triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation <0.4% from the certified values. The relative expanded uncertainties were also comparable with the uncertainties associated with the certified values of the CRM. The validated procedure was used in an External Quality Assessment (EQA) Program organized by our laboratory to establish the assigned values for triglycerides and total glycerides.
40 CFR 152.170 - Criteria for restriction to use by certified applicators.
Code of Federal Regulations, 2012 CFR
2012-07-01
... certified applicators. 152.170 Section 152.170 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Its labeling, when considered according to the factors in paragraph (e)(2) of this section, is not... effects; and (4) The decrease in risks of the pesticide as a result of restriction would exceed the...
40 CFR 152.170 - Criteria for restriction to use by certified applicators.
Code of Federal Regulations, 2014 CFR
2014-07-01
... certified applicators. 152.170 Section 152.170 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Its labeling, when considered according to the factors in paragraph (e)(2) of this section, is not... effects; and (4) The decrease in risks of the pesticide as a result of restriction would exceed the...
40 CFR 152.170 - Criteria for restriction to use by certified applicators.
Code of Federal Regulations, 2013 CFR
2013-07-01
... certified applicators. 152.170 Section 152.170 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Its labeling, when considered according to the factors in paragraph (e)(2) of this section, is not... effects; and (4) The decrease in risks of the pesticide as a result of restriction would exceed the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... without air filters or other portions of the air intake system that are specifically identified by part... appropriate aftertreatment device and/or air filter, but without completing the assembly with all the... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS GENERAL...
Code of Federal Regulations, 2011 CFR
2011-07-01
... without air filters or other portions of the air intake system that are specifically identified by part... appropriate aftertreatment device and/or air filter, but without completing the assembly with all the... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS GENERAL...
ERIC Educational Resources Information Center
Porter, Marclyn D.
2011-01-01
Many alternatively certified teachers, as was the case in this study, are employed as the teacher of record while simultaneously enrolled in education courses. Therefore, experiencing the collaborative, supportive, peer mentoring environmental elements that are present in many traditional "fieldwork" settings is not an option. By…
Using an Experience Documentation Opportunity to Certify Advanced-Level Health Education Specialists
ERIC Educational Resources Information Center
Wilson, Kelly L.; Dennis, Dixie L.; Gambescia, Stephen F.; Chen, W. William; Lysoby, Linda
2012-01-01
The worldwide burden of diseases, environmental threats, and injuries help establish the global context and need for credentialing in health education and promotion. To ensure effective practice by certified or credentialed individuals, it is critical that the global health education and promotion workforce identify, agree on, and establish core…
10 CFR 504.9 - Environmental requirements for certifying powerplants.
Code of Federal Regulations, 2010 CFR
2010-01-01
....9 Section 504.9 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS EXISTING POWERPLANTS § 504.9... regulations, OFP may prohibit the excessive use of natural gas or petroleum in a mixture with an alternate fuel as a primary energy source in a certifying powerplant. (a) NEPA compliance. Except as provided in...
40 CFR Appendix D to Subpart F of... - Standards for Becoming a Certifying Program for Technicians
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Standards for Becoming a Certifying Program for Technicians D Appendix D to Subpart F of Part 82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Recycling and...
40 CFR Appendix D to Subpart F of... - Standards for Becoming a Certifying Program for Technicians
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Standards for Becoming a Certifying Program for Technicians D Appendix D to Subpart F of Part 82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Recycling and...
40 CFR Appendix D to Subpart F of... - Standards for Becoming a Certifying Program for Technicians
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Standards for Becoming a Certifying Program for Technicians D Appendix D to Subpart F of Part 82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Recycling and...
40 CFR Appendix D to Subpart F of... - Standards for Becoming a Certifying Program for Technicians
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Standards for Becoming a Certifying Program for Technicians D Appendix D to Subpart F of Part 82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Recycling and...
40 CFR Appendix D to Subpart F of... - Standards for Becoming a Certifying Program for Technicians
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 18 2014-07-01 2014-07-01 false Standards for Becoming a Certifying Program for Technicians D Appendix D to Subpart F of Part 82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Recycling and...
Kane, J.S.
1991-01-01
A brief history of programs to develop geochemical reference samples and certified reference samples for use in geochemical analysis is presented. While progress has been made since G-1 and W-1 were issued, many challenges remain. ?? 1991.
USDA-ARS?s Scientific Manuscript database
Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets was issued by the National Institute of Standards and Technology (NIST) in 2009 and has certified and reference mass fraction values for 13 vitamins, 26 elements, and 2 carotenoids. Elements were measured using two or more ana...
Development of certified reference materials for electrolytes in human serum (GBW09124-09126).
Feng, Liuxing; Wang, Jun; Cui, Yanjie; Shi, Naijie; Li, Haifeng; Li, Hongmei
2017-05-01
Three reference materials, at relatively low, middle, and high concentrations, were developed for analysis of the mass fractions of electrolytes (K, Ca, Na, Mg, Cl, and Li) in human serum. The reference materials were prepared by adding high purity chloride salts to normal human serum. The concentration range of the three levels is within ±20% of normal human serum. It was shown that 14 units with duplicate analysis is enough to demonstrate the homogeneity of these candidate reference materials. The statistical results also showed no significant trends in both short-term stability test for 1 week at 40 °C and long-term stability test for 14 months. The certification methods of the six elements include isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS), inductively coupled plasma optical emission spectroscopy (ICP-OES), atomic absorption spectroscopy (AAS), ion chromatography (IC), and ion-selective electrode (ISE). The certification methods were validated by international comparisons among a number of national metrology institutes (NMIs). The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the analytical methods, homogeneity, and stability. The range of the expanded uncertainties of all the elements is from 2.2% to 3.9%. The certified reference materials (CRMs) are primarily intended for use in the calibration and validation of procedures in clinical analysis for the determination of electrolytes in human serum or plasma. Graphical Abstract Certified reference materials for K, Ca, Mg, Na, Cl and Li in human serum (GBW09124-09126).
NASA Astrophysics Data System (ADS)
Zhao, Bingshan; He, Man; Chen, Beibei; Xu, Hongrun; Hu, Bin
2018-05-01
In this study, poly(1-vinylimidazole) functionalized gold ion imprinted polymer coated magnetic nanoparticles (MNPs@PVIM-Au-IIP) were prepared and characterized. The adsorption behaviors of the prepared MNPs@PVIM-Au-IIP toward gold ions (Au(III)) were studied, it was found that MNPs@PVIM-Au-IIP has good selectivity, high adsorption capacity (185.4 mg g-1) and fast adsorption kinetic for Au(III). Based on it, a new method of ion imprinted magnetic solid phase extraction (II-MSPE) coupled with graphite furnace atomic absorption spectrometry (GFAAS) detection was proposed for the analysis of trace Au(III) in real samples with complicated matrix. Factors affecting MSPE including sample pH, desorption reagent, elution concentration and volume, elution time, sample volume and adsorption time were optimized. With high enrichment factor of 100-fold, the detection limit of the proposed method is 7.9 ng L-1 for Au(III) with the relative standard deviation of 7.4% (c = 50 ng L-1, n = 7). In order to validate the accuracy of the proposed method, the Certified Reference Material of GBW07293 geological sample (platinpalladium ore) was analyzed, and the determined value was in good agreement with the certified value. The proposed II-MSPE-GFAAS method is simple, fast, selective, sensitive and has been successfully applied in the determination of trace Au in ore, sediment, environmental water and human urine samples with satisfactory results.
Nelson, Michael A; Bedner, Mary; Lang, Brian E; Toman, Blaza; Lippa, Katrice A
2015-11-01
Given the critical role of pure, organic compound primary reference standards used to characterize and certify chemical Certified Reference Materials (CRMs), it is essential that associated mass purity assessments be fit-for-purpose, represented by an appropriate uncertainty interval, and metrologically sound. The mass fraction purities (% g/g) of 25-hydroxyvitamin D (25(OH)D) reference standards used to produce and certify values for clinical vitamin D metabolite CRMs were investigated by multiple orthogonal quantitative measurement techniques. Quantitative (1)H-nuclear magnetic resonance spectroscopy (qNMR) was performed to establish traceability of these materials to the International System of Units (SI) and to directly assess the principal analyte species. The 25(OH)D standards contained volatile and water impurities, as well as structurally-related impurities that are difficult to observe by chromatographic methods or to distinguish from the principal 25(OH)D species by one-dimensional NMR. These impurities have the potential to introduce significant biases to purity investigations in which a limited number of measurands are quantified. Combining complementary information from multiple analytical methods, using both direct and indirect measurement techniques, enabled mitigation of these biases. Purities of 25(OH)D reference standards and associated uncertainties were determined using frequentist and Bayesian statistical models to combine data acquired via qNMR, liquid chromatography with UV absorbance and atmospheric pressure-chemical ionization mass spectrometric detection (LC-UV, LC-ACPI-MS), thermogravimetric analysis (TGA), and Karl Fischer (KF) titration.
Itoh, Nobuyasu; Sato, Ayako; Yamazaki, Taichi; Numata, Masahiko; Takatsu, Akiko
2013-01-01
The carbon, hydrogen, and nitrogen (CHN) contents of alanine and their uncertainties were estimated using a CHN analyzer and the certified reference material (CRM) L-alanine. The CHN contents and their uncertainties, as measured using the single-point calibration method, were 40.36 ± 0.20% for C, 7.86 ± 0.13% for H, and 15.66 ± 0.09% for N; the results obtained using the bracket calibration method were also comparable. The method described in this study is reasonable, convenient, and meets the general requirement of having uncertainties ≤ 0.4%.
ERIC Educational Resources Information Center
Gonyea, Adrian C.
The instructor's guide provides a review for those preparing to take Part IV of the Certified Professional Secretary (CPS) examination. Course content can also help secretaries update their skills in accounting and business mathematics. Organized into lessons with objectives, content outline, and teaching suggestions and references, the units…
40 CFR 1045.660 - How do I certify outboard or personal watercraft engines for use in jet boats?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false How do I certify outboard or personal watercraft engines for use in jet boats? 1045.660 Section 1045.660 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...
40 CFR 1045.660 - How do I certify outboard or personal watercraft engines for use in jet boats?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false How do I certify outboard or personal watercraft engines for use in jet boats? 1045.660 Section 1045.660 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...
40 CFR 1045.660 - How do I certify outboard or personal watercraft engines for use in jet boats?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false How do I certify outboard or personal watercraft engines for use in jet boats? 1045.660 Section 1045.660 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...
Response and Responsibility: Fabrication of the Eco-Certified Citizen in Swedish Curricula 1962-2011
ERIC Educational Resources Information Center
Hillbur, P.; Ideland, M.; Malmberg, C.
2016-01-01
This article addresses the fabrication of the eco-certified citizen, an ideal--rather than real--citizen constructed through requirements of both needed knowledge and a kind of personhood, with specific qualities. The societal demands of knowledge-response to environmental problems are studied, as well as the student's (future citizen's)…
40 CFR 89.914 - What provisions apply to vehicles certified under the motor-vehicle program?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true What provisions apply to vehicles certified under the motor-vehicle program? 89.914 Section 89.914 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exemption...
40 CFR 89.914 - What provisions apply to vehicles certified under the motor-vehicle program?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false What provisions apply to vehicles certified under the motor-vehicle program? 89.914 Section 89.914 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exemption...
40 CFR 89.914 - What provisions apply to vehicles certified under the motor-vehicle program?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false What provisions apply to vehicles certified under the motor-vehicle program? 89.914 Section 89.914 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exemption...
40 CFR 89.914 - What provisions apply to vehicles certified under the motor-vehicle program?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false What provisions apply to vehicles certified under the motor-vehicle program? 89.914 Section 89.914 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exemption...
40 CFR 89.914 - What provisions apply to vehicles certified under the motor-vehicle program?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false What provisions apply to vehicles certified under the motor-vehicle program? 89.914 Section 89.914 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exemption...
USDA-ARS?s Scientific Manuscript database
Establishment of a metrology-based measurement system requires the solid foundation of traceability of measurements to available, appropriate certified reference materials (CRM). In the early 1970s the first “biological” Reference Material (RM) of Bowens Kale, Orchard Leaves, and Bovine Liver from ...
Kinumi, Tomoya; Goto, Mari; Eyama, Sakae; Kato, Megumi; Kasama, Takeshi; Takatsu, Akiko
2012-07-01
A certified reference material (CRM) is a higher-order calibration material used to enable a traceable analysis. This paper describes the development of a C-peptide CRM (NMIJ CRM 6901-a) by the National Metrology Institute of Japan using two independent methods for amino acid analysis based on isotope-dilution mass spectrometry. C-peptide is a 31-mer peptide that is utilized for the evaluation of β-cell function in the pancreas in clinical testing. This CRM is a lyophilized synthetic peptide having the human C-peptide sequence, and contains deamidated and pyroglutamylated forms of C-peptide. By adding water (1.00 ± 0.01) g into the vial containing the CRM, the C-peptide solution in 10 mM phosphate buffer saline (pH 6.6) is reconstituted. We assigned two certified values that represent the concentrations of total C-peptide (mixture of C-peptide, deamidated C-peptide, and pyroglutamylated C-peptide) and C-peptide. The certified concentration of total C-peptide was determined by two amino acid analyses using pre-column derivatization liquid chromatography-mass spectrometry and hydrophilic chromatography-mass spectrometry following acid hydrolysis. The certified concentration of C-peptide was determined by multiplying the concentration of total C-peptide by the ratio of the relative area of C-peptide to that of the total C-peptide measured by liquid chromatography. The certified value of C-peptide (80.7 ± 5.0) mg/L represents the concentration of the specific entity of C-peptide; on the other hand, the certified value of total C-peptide, (81.7 ± 5.1) mg/L can be used for analyses that does not differentiate deamidated and pyroglutamylated C-peptide from C-peptide itself, such as amino acid analyses and immunochemical assays.
Novel approach in k0-NAA for highly concentrated REE Samples.
Abdollahi Neisiani, M; Latifi, M; Chaouki, J; Chilian, C
2018-04-01
The present paper presents a new approach for k 0 -NAA for accurate quantification with short turnaround analysis times for rare earth elements (REEs) in high content mineral matrices. REE k 0 and Q 0 values, spectral interferences and nuclear interferences were experimentally evaluated and improved with Alfa Aesar Specpure Plasma Standard 1000mgkg -1 mono-rare earth solutions. The new iterative gamma-ray self-attenuation and neutron self-shielding methods were investigated with powder standards prepared from 100mg of 99.9% Alfa Aesar mono rare earth oxide diluted with silica oxide. The overall performance of the new k 0 -NAA method for REEs was validated using a certified reference material (CRM) from Canadian Certified Reference Materials Project (REE-2) with REE content ranging from 7.2mgkg -1 for Yb to 9610mgkg -1 for Ce. The REE concentration was determined with uncertainty below 7% (at 95% confidence level) and proved good consistency with the CRM certified concentrations. Copyright © 2017 Elsevier B.V. All rights reserved.
Certified ion implantation fluence by high accuracy RBS.
Colaux, Julien L; Jeynes, Chris; Heasman, Keith C; Gwilliam, Russell M
2015-05-07
From measurements over the last two years we have demonstrated that the charge collection system based on Faraday cups can robustly give near-1% absolute implantation fluence accuracy for our electrostatically scanned 200 kV Danfysik ion implanter, using four-point-probe mapping with a demonstrated accuracy of 2%, and accurate Rutherford backscattering spectrometry (RBS) of test implants from our quality assurance programme. The RBS is traceable to the certified reference material IRMM-ERM-EG001/BAM-L001, and involves convenient calibrations both of the electronic gain of the spectrometry system (at about 0.1% accuracy) and of the RBS beam energy (at 0.06% accuracy). We demonstrate that accurate RBS is a definitive method to determine quantity of material. It is therefore useful for certifying high quality reference standards, and is also extensible to other kinds of samples such as thin self-supporting films of pure elements. The more powerful technique of Total-IBA may inherit the accuracy of RBS.
Montoro Leal, P; Vereda Alonso, E; López Guerrero, M M; Cordero, M T Siles; Cano Pavón, J M; García de Torres, A
2018-07-01
Arsenic, one of the main environmental pollutants and potent natural poison, is a chemical element that is spread throughout the Earth's crust. It is well known that the toxicity of arsenic is highly dependent on its chemical forms. Generally, the inorganic species are more toxic than its organics forms, and As(III) is 60 times more toxic than As(V). In environmental waters, arsenic exists predominantly in two chemical forms: As(III) and As(V). In view of these facts, fast, sensitive, accurate and simple analytical methods for the speciation of inorganic arsenic in environmental waters are required. In this work, a new magnetic solid phase extraction with a hydride generation system was coupled on line with inductively coupled plasma mass spectrometry (MSPE-HG-ICP-MS). The new system was based on the retention of As(III) and As(V) in two knotted reactors filled with (Fe 3 O 4 ) magnetic nanoparticles functionalized with [1,5-bis (2-pyridyl) 3-sulfophenylmethylene] thiocarbonohydrazide (PSTH-MNPs). As(III) and total inorganic As were sequentially eluted in different reduction conditions. The concentration of As(V) was obtained by subtracting As(III) from total As. The system runs in a fully automated way and the method has proved to have a wide linear range and to be precise, sensitive and fast. The detection limits found were 2.7 and 3.2 ng/L for As(III) and total As, respectively; with relative standard deviations (RSDs) of 2.5% and 2.7% and a sample throughput of 14.4 h -1 . In order to validate the developed method, several certified reference samples of environmental waters including sea water, were analyzed and the determined values were in good agreement with the certified values. The proposed method was successfully applied to the speciation analysis of inorganic arsenic in well-water and sea water. Copyright © 2018 Elsevier B.V. All rights reserved.
Transforming an EPA QA/R-2 quality management plan into an ISO 9002 quality management system.
Kell, R A; Hedin, C M; Kassakhian, G H; Reynolds, E S
2001-01-01
The Environmental Protection Agency's (EPA) Office of Emergency and Remedial Response (OERR) requires environmental data of known quality to support Superfund hazardous waste site projects. The Quality Assurance Technical Support (QATS) Program is operated by Shaw Environmental and Infrastructure, Inc. to provide EPA's Analytical Operations Center (AOC) with performance evaluation samples, reference materials, on-site laboratory auditing capabilities, data audits (including electronic media data audits), methods development, and other support services. The new QATS contract awarded in November 2000 required that the QATS Program become ISO 9000 certified. In a first for an EPA contractor, the QATS staff and management successfully transformed EPA's QA/R-2 type Quality Management Plan into a Quality Management System (QMS) that complies with the requirements of the internationally recognized ISO 9002 standard and achieved certification in the United States, Canada, and throughout Europe. The presentation describes how quality system elements of ISO 9002 were implemented on an already existing quality system. The psychological and organizational challenges of the culture change in QATS' day-to-day operations will be discussed for the benefit of other ISO 9000 aspirants.
Quantitative aspects of inductively coupled plasma mass spectrometry
Wagner, Barbara
2016-01-01
Accurate determination of elements in various kinds of samples is essential for many areas, including environmental science, medicine, as well as industry. Inductively coupled plasma mass spectrometry (ICP-MS) is a powerful tool enabling multi-elemental analysis of numerous matrices with high sensitivity and good precision. Various calibration approaches can be used to perform accurate quantitative measurements by ICP-MS. They include the use of pure standards, matrix-matched standards, or relevant certified reference materials, assuring traceability of the reported results. This review critically evaluates the advantages and limitations of different calibration approaches, which are used in quantitative analyses by ICP-MS. Examples of such analyses are provided. This article is part of the themed issue ‘Quantitative mass spectrometry’. PMID:27644971
Rhoderick, George C
2007-04-01
New US federal low-level automobile emission requirements, for example zero-level-emission vehicle (ZLEV), for hydrocarbons and other species, have resulted in the need by manufacturers for new certified reference materials. The new emission requirement for hydrocarbons requires the use, by automobile manufacturing testing facilities, of a 100 nmol mol(-1) propane in air gas standard. Emission-measurement instruments are required, by federal law, to be calibrated with National Institute of Standards and Technology (NIST) traceable reference materials. Because a NIST standard reference material (SRM) containing 100 nmol mol(-1) propane was not available, the US Environmental Protection Agency (EPA) and the Automobile Industry/Government Emissions Research Consortium (AIGER) requested that NIST develop such an SRM. A cylinder lot of 30 gas mixtures containing 100 nmol mol(-1) propane in air was prepared in 6-L aluminium gas cylinders by a specialty gas company and delivered to the Gas Metrology Group at NIST. Another mixture, contained in a 30-L aluminium cylinder and included in the lot, was used as a lot standard (LS). Using gas chromatography with flame-ionization detection all 30 samples were compared to the LS to obtain the average of six peak-area ratios to the LS for each sample with standard deviations of <0.31%. The average sample-to-LS ratio determinations resulted in a range of 0.9828 to 0.9888, a spread of 0.0060, which corresponds to a relative standard deviation of 0.15% of the average for all 30 samples. NIST developed its first set of five propane in air primary gravimetric standards covering a concentration range 91 to 103 nmol mol(-1) with relative uncertainties of 0.15%. This new suite of propane gravimetric standards was used to analyze and assign a concentration value to the SRM LS. On the basis of these data each SRM sample was individually certified, furnishing the desired relative expanded uncertainty of +/-0.5%. Because automobile companies use total hydrocarbons to make their measurements, it was also vital to assign a methane concentration to the SRM samples. Some of the SRM samples were analyzed and found to contain 1.2 nmol mol(-1) methane. Twenty-five of the samples were certified and released as SRM 2765.
Remotely Piloted Aircraft (RPA) Performing the Air Refueling Mission
2012-06-01
Expeditionary Center librarian , thank you for your year- long continual search for any and all references applicable to this study. To my classmate Major...priorities about which missions will require certified pilots and which do not; whether low-cost, low-tech alternatives exist to do basic reconnaissance...flights in civil airspace! The Federal Aviation Administration (FAA) recognizes that a certifiable “detect, sense, and avoid” solution to the “see
Kawaguchi, Migaku; Takatsu, Akiko
2009-08-01
A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.
Evaluation of critical indicators in the process of acquiring supplies and services LAC-UFPE
NASA Astrophysics Data System (ADS)
Caetano, V. F.; Ferreira, C. V.; dos Santos, M. J.; Honorato, F. A.
2015-01-01
In laboratories linked to public universities and accredited by the NBR ISO/IEC 17025, to meet efficiently item 4.6 (procurement of supplies and services) is a challenge that can be accomplished by programming based on historical purchases and services. In this study, we evaluated the critical procurement items to meet the quality management system of the LAC-UFPE: reagents, certified reference material, of equipment parts, maintenance and calibration of equipment and instruments. It was found that the most critical item is the certified reference material, the purchase or repair of which must be expedited within 125 days prior to the receipt to occur within the desired period.
Determination of Vitamin E in Cereal Products and Biscuits by GC-FID.
Pasias, Ioannis N; Kiriakou, Ioannis K; Papakonstantinou, Lila; Proestos, Charalampos
2018-01-01
A rapid, precise and accurate method for the determination of vitamin E (α-tocopherol) in cereal products and biscuits has been developed. The uncertainty was calculated for the first time, and the methods were performed for different cereal products and biscuits, characterized as "superfoods". The limits of detection and quantification were calculated. The accuracy and precision were estimated using the certified reference material FAPAS T10112QC, and the determined values were in good accordance with the certified values. The health claims according to the daily reference values for vitamin E were calculated, and the results proved that the majority of the samples examined showed a percentage daily value higher than 15%.
Determination of Vitamin E in Cereal Products and Biscuits by GC-FID
Kiriakou, Ioannis K.; Papakonstantinou, Lila
2018-01-01
A rapid, precise and accurate method for the determination of vitamin E (α-tocopherol) in cereal products and biscuits has been developed. The uncertainty was calculated for the first time, and the methods were performed for different cereal products and biscuits, characterized as “superfoods”. The limits of detection and quantification were calculated. The accuracy and precision were estimated using the certified reference material FAPAS T10112QC, and the determined values were in good accordance with the certified values. The health claims according to the daily reference values for vitamin E were calculated, and the results proved that the majority of the samples examined showed a percentage daily value higher than 15%. PMID:29301245
Development of internal forest soil reference samples and testing of digestion methods
J.E. Hislop; J.W. Hornbeck; S.W. Bailey; R.A. Hallett
1998-01-01
Our research requires determinations of total elemental concentrations of forest soils. The lack of certified forest soil reference materials led us to develop internal reference samples. Samples were collected from three soil horizons (Oa, B, and C) at three locations having forested, acidic soils similar to those we commonly analyze. A shatterbox was used to...
An Examination of Forest Certification Status among Logging Companies in Cameroon
Nukpezah, Daniel; Alemagi, Dieudonne; Duguma, Lalisa; Minang, Peter; Mbosso, Charlie; Tchoundjeu, Zac
2014-01-01
This paper assesses the level of interest, awareness, and adoption of ISO 14001 and Forest Stewardship Council (FSC) certification schemes among logging companies in Cameroon. Eleven logging companies located in Douala in the Littoral Region of Cameroon were assessed through a structured interview using an administered questionnaire which was mostly analyzed qualitatively thereafter. The findings indicated that none of the companies was certified for ISO 14001; however 63.64% of them were already FSC-certified. Four companies (36.36%) were neither FSC- nor ISO 14001 EMS-certified. Among the factors found to influence the adoption rate was the level of awareness about ISO 14001 and FSC certification schemes. The main drivers for pursuing FSC certification were easy penetration into international markets, tax holiday benefits, and enhancement of corporate image of the logging companies through corporate social responsibility fulfillments. Poor domestic market for certified products was found to be the major impediment to get certified. To make logging activities more environmentally friendly and socially acceptable, logging companies should be encouraged to get certified through the ISO 14001 EMS scheme which is almost nonexistent so far. This requires awareness creation about the scheme, encouraging domestic markets for certified products and creating policy incentives. PMID:27355041
An Examination of Forest Certification Status among Logging Companies in Cameroon.
Nukpezah, Daniel; Alemagi, Dieudonne; Duguma, Lalisa; Minang, Peter; Mbosso, Charlie; Tchoundjeu, Zac
2014-01-01
This paper assesses the level of interest, awareness, and adoption of ISO 14001 and Forest Stewardship Council (FSC) certification schemes among logging companies in Cameroon. Eleven logging companies located in Douala in the Littoral Region of Cameroon were assessed through a structured interview using an administered questionnaire which was mostly analyzed qualitatively thereafter. The findings indicated that none of the companies was certified for ISO 14001; however 63.64% of them were already FSC-certified. Four companies (36.36%) were neither FSC- nor ISO 14001 EMS-certified. Among the factors found to influence the adoption rate was the level of awareness about ISO 14001 and FSC certification schemes. The main drivers for pursuing FSC certification were easy penetration into international markets, tax holiday benefits, and enhancement of corporate image of the logging companies through corporate social responsibility fulfillments. Poor domestic market for certified products was found to be the major impediment to get certified. To make logging activities more environmentally friendly and socially acceptable, logging companies should be encouraged to get certified through the ISO 14001 EMS scheme which is almost nonexistent so far. This requires awareness creation about the scheme, encouraging domestic markets for certified products and creating policy incentives.
Krachler, M
2001-12-01
Two electronic moisture analyzers were critically evaluated with regard to their suitability for determining moisture in small amounts (< or = 200 mg) of various environmental matrices such as leaves, needles, soil, peat, sediments, and sewage sludge, as well as various biological reference materials. To this end, several homogeneous bulk materials were prepared which were subsequently employed for the development and optimization of all analytical procedures. The key features of the moisture analyzers included a halogen or ceramic heater and an integrated balance with a resolution of 0.1 mg, which is an essential prerequisite for obtaining precise results. Oven drying of the bulk materials in a conventional oven at 105 degrees C until constant mass served as reference method. A heating temperature of 65degrees C was found to provide accurate and precise results for almost all matrices investigated. To further improve the accuracy and precision, other critical parameters such as handling of sample pans, standby temperature, and measurement delay were optimized. Because of its ponderous heating behavior, the performance of the ceramic radiator was inferior to that of the halogen heater, which produced moisture results comparable to those obtained by oven drying. The developed drying procedures were successfully applied to the fast moisture analysis (1.4-6.3 min) of certified biological reference materials of similar provenance to the investigated the bulk materials. Moisture results for 200 mg aliquots ranged from 1.4 to 7.8% and good agreement was obtained between the recommended drying procedure for the reference materials and the electronic moisture analyzers with absolute uncertainties amounting to 0.1% and 0.2-0.3%, respectively.
New NIST sediment SRM for inorganic analysis.
Zeisler, Rolf
2004-03-01
NIST maintains a portfolio of more than 1300 standard reference materials (SRM), more than a third of these relating to measurements in the biological and environmental fields. As part of the continuous renewal and replacement efforts, a set of new marine sediments has been recently developed covering organic and inorganic determinations. This paper describes the steps taken in sample preparation, homogeneity assay, and analytical characterization and certification with specific emphasis on SRM 2702 inorganics in marine sediment. Neutron activation analysis showed the SRM to be highly homogeneous, opening the possibility for use with solid sampling techniques. The certificate provides certified mass fraction values for 25 elements, reference values for eight elements, and information values for 11 elements, covering most of the priority pollutants with small uncertainties of only several percent relative. The values were obtained by combining results from different laboratories and techniques using a Bayesian statistical model. An intercomparison carried out in field laboratories with the material before certification illustrates a high commutability of this SRM.
Development and certification of the new SRM 695 trace elements in multi-nutrient fertilizer
MacKey, E.A.; Cronise, M.P.; Fales, C.N.; Greenberg, R.R.; Leigh, S.D.; Long, S.E.; Marlow, A.F.; Murphy, K.E.; Oflaz, R.; Sieber, J.R.; Rearick, M.S.; Wood, L.J.; Yu, L.L.; Wilson, S.A.; Briggs, P.H.; Brown, Z.A.; Budahn, J.; Kane, P.F.; Hall, W.L.
2007-01-01
During the past seven years, several states within the US have enacted regulations that limit the amounts of selected non-nutritive elements in fertilizers. Internationally, several countries, including Japan, China, and Australia, and the European Union also limit the amount of selected elements in fertilizers. The elements of interest include As, Cd, Co, Cr, Cu, Hg, Mo, Ni, Pb, Se, and Zn. Fertilizer manufacturers and state regulatory authorities, faced with meeting and verifying these limits, need to develop analytical methods for determination of the elements of concern and to validate results obtained using these methods. Until now, there were no certified reference materials available with certified mass fraction values for all elements of interest in a blended, multi-nutrient fertilizer matrix. A new standard reference material (SRM) 695 trace elements in multi-nutrient fertilizer, has been developed to help meet these needs. SRM 695 has recently been issued with certified mass fraction values for seventeen elements, reference values for an additional five elements, and information values for two elements. The certificate of analysis includes an addendum listing percentage recovery for eight of these elements, determined using an acid-extraction inductively-coupled plasma optical-emission spectrometry (ICP-OES) method recently developed and tested by members of the Association of American Plant Food Control Officials. ?? Springer-Verlag 2007.
Kato, Megumi; Yamazaki, Taichi; Kato, Hisashi; Eyama, Sakae; Goto, Mari; Yoshioka, Mariko; Takatsu, Akiko
2015-01-01
To ensure the reliability of amino acid analyses, the National Metrology Institute of Japan of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed high-purity certified reference materials (CRMs) for 17 proteinogenic amino acids. These CRMs are intended for use as primary reference materials to enable the traceable quantification of amino acids. The purity of the present CRMs was determined based on two traceable methods: nonaqueous acidimetric titration and nitrogen determination by the Kjeldahl method. Since neither method could distinguish compounds with similar structures, such as amino acid-related impurities, impurities were thoroughly quantified by combining several HPLC methods, and subtracted from the obtained purity of each method. The property value of each amino acid was calculated as a weighted mean of the corrected purities by the two methods. The uncertainty of the property value was obtained by combining measurement uncertainties of the two methods, a difference between the two methods, the uncertainty from the contribution of impurities, and the uncertainty derived from inhomogeneity. The uncertainty derived from instability was considered to be negligible based on stability monitoring of some CRMs. The certified value of each amino acid, property value with uncertainty, was given for both with or without enantiomeric separation.
Zhou, Tao; Zhao, Motian; Wang, Jun; Lu, Hai
2008-01-01
Two enriched isotopes, 99.94 at.% 56Fe and 99.90 at.% 54Fe, were blended under gravimetric control to prepare ten synthetic isotope samples whose 56Fe isotope abundances ranged from 95% to 20%. For multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements typical polyatomic interferences were removed by using Ar and H2 as collision gas and operating the MC-ICP-MS system in soft mode. Thus high-precision measurements of the Fe isotope abundance ratios were accomplished. Based on the measurement of the synthetic isotope abundance ratios by MC-ICP-MS, the correction factor for mass discrimination was calculated and the results were in agreement with results from IRMM014. The precision of all ten correction factors was 0.044%, indicating a good linearity of the MC-ICP-MS method for different isotope abundance ratio values. An isotopic reference material was certified under the same conditions as the instrument was calibrated. The uncertainties of ten correction factors K were calculated and the final extended uncertainties of the isotopic certified Fe reference material were 5.8363(37) at.% 54Fe, 91.7621(51) at.% 56Fe, 2.1219(23) at.% 57Fe, and 0.2797(32) at.% 58Fe.
Sánchez, Raquel; Snell, James; Held, Andrea; Emons, Hendrik
2015-08-01
A simple, robust and reliable method for mercury determination in seawater matrices based on the combination of cold vapour generation and inductively coupled plasma mass spectrometry (CV-ICP-MS) and its complete in-house validation are described. The method validation covers parameters such as linearity, limit of detection (LOD), limit of quantification (LOQ), trueness, repeatability, intermediate precision and robustness. A calibration curve covering the whole working range was achieved with coefficients of determination typically higher than 0.9992. The repeatability of the method (RSDrep) was 0.5 %, and the intermediate precision was 2.3 % at the target mass fraction of 20 ng/kg. Moreover, the method was robust with respect to the salinity of the seawater. The limit of quantification was 2.7 ng/kg, which corresponds to 13.5 % of the target mass fraction in the future certified reference material (20 ng/kg). An uncertainty budget for the measurement of mercury in seawater has been established. The relative expanded (k = 2) combined uncertainty is 6 %. The performance of the validated method was demonstrated by generating results for process control and a homogeneity study for the production of a candidate certified reference material.
Development of NIST standard reference material 2373: Genomic DNA standards for HER2 measurements.
He, Hua-Jun; Almeida, Jamie L; Lund, Steve P; Steffen, Carolyn R; Choquette, Steve; Cole, Kenneth D
2016-06-01
NIST standard reference material (SRM) 2373 was developed to improve the measurements of the HER2 gene amplification in DNA samples. SRM 2373 consists of genomic DNA extracted from five breast cancer cell lines with different amounts of amplification of the HER2 gene. The five components are derived from the human cell lines SK-BR-3, MDA-MB-231, MDA-MB-361, MDA-MB-453, and BT-474. The certified values are the ratios of the HER2 gene copy numbers to the copy numbers of selected reference genes DCK, EIF5B, RPS27A, and PMM1. The ratios were measured using quantitative polymerase chain reaction and digital PCR, methods that gave similar ratios. The five components of SRM 2373 have certified HER2 amplification ratios that range from 1.3 to 17.7. The stability and homogeneity of the reference materials were shown by repeated measurements over a period of several years. SRM 2373 is a well characterized genomic DNA reference material that can be used to improve the confidence of the measurements of HER2 gene copy number.
Sin, Della Wai-Mei; Wong, Yee-Lok; Cheng, Eddie Chung-Chin; Lo, Man-Fung; Ho, Clare; Mok, Chuen-Shing; Wong, Siu-Kay
2015-04-01
This paper presents the certification of alpha-endosulfan, beta-endosulfan, and endosulfan sulfate in a candidate tea certified reference material (code: GLHK-11-03) according to the requirements of the ISO Guide 30 series. Certification of GLHK-11-03 was based on an analytical method purposely developed for the accurate measurement of the mass fraction of the target analytes in the material. An isotope dilution mass spectrometry (IDMS) method involving determination by (i) gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS) and (ii) gas chromatography-electron ionization-high-resolution mass spectrometry (GC-EI-HRMS) techniques was employed. The performance of the described method was demonstrated through participation in the key comparison CCQM-K95 "Mid-Polarity Analytes in Food Matrix: Mid-Polarity Pesticides in Tea" organized by the Consultative Committee for Amount of Substance-Metrology in Chemistry in 2012, where the study material was the same as the certified reference material (CRM). The values reported by using the developed method were in good agreement with the key comparison reference value (KCRV) assigned for beta-endosulfan (727 ± 14 μg kg(-1)) and endosulfan sulfate (505 ± 11 μg kg(-1)), where the degree of equivalence (DoE) values were 0.41 and 0.40, respectively. The certified values of alpha-endosulfan, beta-endosulfan, and endosulfan sulfate in dry mass fraction in GLHK-11-03 were 350, 730, and 502 μg kg(-1), respectively, and the respective expanded uncertainties, due to sample inhomogeneity, long-term and short-term stability, and variability in the characterization procedure, were 27 μg kg(-1) (7.8 %), 48 μg kg(-1) (6.6 %), and 33 μg kg(-1) (6.6 %).
Contaminant concentration in environmental samples using LIBS and CF-LIBS
NASA Astrophysics Data System (ADS)
Pandhija, S.; Rai, N. K.; Rai, A. K.; Thakur, S. N.
2010-01-01
The present paper deals with the detection and quantification of toxic heavy metals like Cd, Co, Pb, Zn, Cr, etc. in environmental samples by using the technique of laser-induced breakdown spectroscopy (LIBS) and calibration-free LIBS (CF-LIBS). A MATLABTM program has been developed based on the CF-LIBS algorithm given by earlier workers and concentrations of pollutants present in industrial area soil have been determined. LIBS spectra of a number of certified reference soil samples with varying concentrations of toxic elements (Cd, Zn) have been recorded to obtain calibration curves. The concentrations of Cd and Zn in soil samples from the Jajmau area, Kanpur (India) have been determined by using these calibration curves and also by the CF-LIBS approach. Our results clearly demonstrate that the combination of LIBS and CF-LIBS is very useful for the study of pollutants in the environment. Some of the results have also been found to be in good agreement with those of ICP-OES.
Sustainable Architecture that Teaches: Promoting Environmental Education through Service-Learning
ERIC Educational Resources Information Center
Eason, Grace; Berger, Rebecca; Green, Pamela Davis
2010-01-01
The University of Maine at Farmington (UMF) has undertaken a commitment to establish a culture of environmental sustainability. With two new Leadership in Energy and Environmental Design (LEED) certified buildings on site, a green building curriculum has been developed. This multidimensional curriculum involves university faculty, students, K-12…
The production and certification of a plutonium equal-atom reference material: NBL CRM 128
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, D.W.; Gradle, C.G.; Soriano, M.D.
This report describes the design, production, and certification of the New Brunswick Laboratory plutonium equal-atom certified reference material (CRM), NBL CRM 128. The primary use of this CRM is for the determination of bias corrections encountered in the operation of a mass spectrometer. This reference material is available to the US Department of Energy contractor-operated and government-operated laboratories, as well as to the international nuclear safeguards community. The absolute, or unbiased, certified value for the CRM's Pu-242/Pu-239 ratio is 1.00063 {plus minus} 0.00026 (95% confidence interval) as of October 1, 1984. This value was obtained through the quantitative blending ofmore » high-purity, chemically and isotopically characterized separated isotopes, as well as through intercomparisons of CRM samples with calibration mixtures using thermal ionization mass spectrometry. 32 tabs.« less
Aluminium-gold reference material for the k0-standardisation of neutron activation analysis
NASA Astrophysics Data System (ADS)
Ingelbrecht, C.; Peetermans, F.; De Corte, F.; De Wispelaere, A.; Vandecasteele, C.; Courtijn, E.; D'Hondt, P.
1991-05-01
Gold is an excellent comparator material for the k0-standardisation of neutron activation analysis because of its convenient and well defined nuclear properties. The most suitable form for a reference material is a dilute aluminium-gold alloy, for which the self-shielding effect for neutrons is small. Castings of composition Al-0.1 wt.% Au were prepared by crucible-less levitation melting, which gives close control of ingot composition with minimal contamination of the melt. The alloy composition was checked using induction-coupled plasma source emission spectrometry. The homogeneity of the alloy was measured by neutron activation analysis and a relative standard deviation of the gold content of 0.30% was found (10 mg samples). Metallography revealed a homogeneous distribution of AuAl 2 particles. The alloy was certified as Reference Material CBNM-530, with certified gold mass fraction 0.100±0.002 wt.%.
Dombovári, J; Becker, J S; Dietze, H J
2000-07-01
The lowest possible sample weight for performing multielemental trace element analysis on environmental and biological samples by ICP-MS has been investigated. The certified reference materials Bovine Liver NIST SRM 1577b, Human Hair NCS DC 73347 and Oriental Tobacco Leaves CTA-OTL-1 were applied at sample weights (1, 5, 20 and 50 mg aliquots, n = 10) which were significantly lower than those recommended with most recoveries in the range of 95-110%. Samples were digested in a mixture of nitric acid, hydrogen peroxide and hydrogen fluoride by closed-vessel microwave digestion. Multielemental analysis was performed with an optimized ICP-QMS method. Aqueous standard solutions were applied for external calibration with rhodium as the internal standard element. The detection limits varied between 0.02-0.38 microg/g for Li, Na, Cr, Mn, Ni, Cu, Zn, Sr, Cd, Ba and Pb, and up to 1.92 microg/g for Mg, Al, Ca, Fe and Ni. Digested human plasma samples were spiked with multielemental solution (0.5-10 microg/L) to test the analytical method and the recoveries were 95-105% for most analytes. Our results show that in the case of homogeneous SRMs it is possible to use them in very low amounts (1-5 mg) for method development and quality control.
Toussaint, B; Schimmel, H; Klein, C L; Wiergowski, M; Emons, H
2007-07-13
The certification of the purity of CRMs intended for calibration, where no other certified material already exists for comparison, raises principle questions on how to determine the purity of a "first" calibrant in the calibration hierarchy. We developed and certified two calibration CRMs for their purity in thyroid hormones taking into consideration inorganic residues, residual solvents and organic impurities detectable by HPLC-UV and HPLC-MS. IRMM-468 was certified for a thyroxine (T(4)) mass fraction of 98.6+/-0.7% and IRMM-469 was certified for a 3,3',5-triiodothyronine (T(3)) mass fraction of 97.1+/-0.7%. The approach we used aims to determine the purity of these two CRMs to the best of our knowledge and taking all scientific aspects properly into account for the estimation of an uncertainty related to the stated purity.
Ceballos, Melisa Rodas; García-Tenorio, Rafael; Estela, José Manuel; Cerdà, Víctor; Ferrer, Laura
2017-12-01
Leached fractions of U and Th from different environmental solid matrices were evaluated by an automatic system enabling the on-line lixiviation and extraction/pre-concentration of these two elements previous ICP-MS detection. UTEVA resin was used as selective extraction material. Ten leached fraction, using artificial rainwater (pH 5.4) as leaching agent, and a residual fraction were analyzed for each sample, allowing the study of behavior of U and Th in dynamic lixiviation conditions. Multivariate techniques have been employed for the efficient optimization of the independent variables that affect the lixiviation process. The system reached LODs of 0.1 and 0.7ngkg -1 of U and Th, respectively. The method was satisfactorily validated for three solid matrices, by the analysis of a soil reference material (IAEA-375), a certified sediment reference material (BCR- 320R) and a phosphogypsum reference material (MatControl CSN-CIEMAT 2008). Besides, environmental samples were analyzed, showing a similar behavior, i.e. the content of radionuclides decreases with the successive extractions. In all cases, the accumulative leached fraction of U and Th for different solid matrices studied (soil, sediment and phosphogypsum) were extremely low, up to 0.05% and 0.005% of U and Th, respectively. However, a great variability was observed in terms of mass concentration released, e.g. between 44 and 13,967ngUkg -1 . Copyright © 2017 Elsevier B.V. All rights reserved.
Stroh, Christine; Köckerling, F; Lange, V; Wolff, S; Knoll, C; Bruns, C; Manger, Th
2017-02-01
To examine the association between the certification as bariatric surgery center and volume and patient outcome, data collected in the German Bariatric Surgery Registry were evaluated. All data were registered prospectively in cooperation with the Institute of Quality Assurance in Surgery at Otto-von-Guericke University Magdeburg. Data collection began in 2005 for all bariatric procedures in an online database. Participation in the quality assurance study is required for all certified bariatric surgery centers in Germany. Descriptive evaluation and matched pairs analysis were performed. Patients were matched via propensity score taking into account BMI, age, and incidence of comorbidities. During the period from 2005 to 2013, 3083 male and 10,639 female patients were operated on with the RYGB primary approach. In Centers of Competence (77.2 %) and non-accredited hospitals (76.3 %), the proportion of female patients was significantly lower than in Centers of Reference/Excellence (78.7 %; p = 0.002). The mean age in Centers of Reference/Excellence (41.2 years) was significantly lower than in Centers of Competence (43.2 years; p < 0.05). Propensity score analysis was performed to compare matched patients with regard to BMI, age, and incidence of comorbidities. The rate of general and surgical postoperative complications and mortality rate was significantly lower in certified Centers of Reference/Excellence compared to Centers of Competence with 29 and non-certified hospitals. There is evidence of improved patient outcome in certified bariatric surgery centers with higher volume. The study supports the concept of certification. There are different factors which can and cannot be preoperatively modified and influence the perioperative outcome.
Reference Materials for Food and Nutrition Metrology: Past, Present and Future
USDA-ARS?s Scientific Manuscript database
Establishment of a metrology-based measurement system requires the solid foundation of traceability of measurements to available, appropriate certified reference materials (CRM). In the early 1970’s the first “biological” RM of Bowens Kale, as well as Orchard Leaves and Bovine Liver SRMs, from the ...
TWO NEW GAS STANDARDS PROGRAMS AT THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
The EPA/NIST certified reference materials (CRM) program is being terminated and replaced with two new ones: the NIST Traceable Reference Materials (NTRM) and the Research Gas Mixture (RGM) programs. hese new programs are being implemented to provide NIST traceability to a wider ...
Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Jia; Sun, Guohua; Li, Hongmei
2012-10-15
Certified reference materials (CRMs) of water content are widely used in the calibration and validation of Karl Fischer coulometry and volumetry. In this study, the water content of the water saturated 1-octanol (WSO) CRM was certified by Karl Fischer coulometry, volumetry and quantitative nuclear magnetic resonance (Q NMR). The water content recovery by coulometry was 99.76% with a diaphragm-less electrode and Coulomat AG anolyte. The relative bias between the coulometry and volumetry results was 0.06%. In Q NMR, the water content of WSO is traceable to the International System (SI) of units through the purity of internal standard. The relative bias of water content in WSO between Q NMR and volumetry was 0.50%. The consistency of results for these three independent methods improves the accuracy of the certification of the RM. The certified water content of the WSO CRM was 4.76% with an expanded uncertainty of 0.09%. Copyright © 2012 Elsevier Ltd. All rights reserved.
Fernández, Beatriz; Rodríguez-González, Pablo; García Alonso, J Ignacio; Malherbe, Julien; García-Fonseca, Sergio; Pereiro, Rosario; Sanz-Medel, Alfredo
2014-12-03
We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6-21% for pressed pellets and 3-21% for fused solids were obtained from n=3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches. Copyright © 2014 Elsevier B.V. All rights reserved.
Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric
2016-08-01
Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.
HEALTH CARE GUIDE TO POLLUTION PREVENTION IMPLEMENTATION THROUGH ENVIRONMENTAL MANAGEMENT SYSTEMS
The Health Care Guide to Pollution Prevention Implementation through Environmental Management Systems provides example EMS procedures and forms used in four ISO 14001 EMS certified hospitals. The latest revisions include more EMS hospital case studies, more compliance resources, ...
ENVIRONMENTAL TECHNOLOGY VERIFICATION OF BAGHOUSE FILTRATION PRODUCTS
The Environmental Technology Verification Program (ETV) was started by EPA in 1995 to generate independent credible data on the performance of innovative technologies that have potential to improve protection of public health and the environment. ETV does not approve or certify p...
Lyznicki, James M.; Riggs, Joseph A.; Champion, Hunter C.
1999-01-01
Background: In June 1997, the American Academy of Pediatrics introduced a resolution asking the American Medical Association (AMA) to support efforts to place certified athletic trainers in all secondary schools. The AMA Council on Scientific Affairs studied that resolution and presented this report to the AMA House of Delegates in June 1998. Objective: To identify the professional responsibilities, educational requirements, and current use of certified athletic trainers in the prevention and care of high school sports injuries. Data Sources: MEDLINE and HealthSTAR databases were searched for English-language articles published from 1980 to 1998. Additional references were derived from references in pertinent articles, communication with experts, and the Internet sites of athletic training and sports medicine associations. Data Synthesis: One in 5 of approximately 6 million adolescents who participate in high school sports each year sustains a sport-related injury. Most of these injuries are minor and occur during practices rather than competitions. Approximately 1 of every 100000 high school athletes will sustain a catastrophic injury. About 35% of US high schools use the services of a certified athletic trainer, who, under a physician's supervision, is responsible for the prevention and care of athletic injuries and coordination of the school athletic health program. Conclusions/Recommendations: Emphasis should be given to ensuring the health, safety, and well-being of participants in high school sports. Whereas most high school sports injuries are minor, adequately trained personnel should be present on site to ensure that such injuries are recognized early, treated immediately, and allowed to heal properly, thereby reducing the risk of more serious injury or reinjury. For such care, team physicians and coaches should have the assistance of a certified athletic trainer. PMID:16558576
Kato, Megumi; Kinumi, Tomoya; Yoshioka, Mariko; Goto, Mari; Fujii, Shin-Ichiro; Takatsu, Akiko
2015-04-01
To standardize C-reactive protein (CRP) assays, the National Metrology Institute of Japan (NMIJ) has developed a C-reactive protein solution certified reference material, CRM 6201-b, which is intended for use as a primary reference material to enable the SI-traceable measurement of CRP. This study describes the development process of CRM 6201-b. As a candidate material of the CRM, recombinant human CRP solution was selected because of its higher purity and homogeneity than the purified material from human serum. Gel filtration chromatography was used to examine the homogeneity and stability of the present CRM. The total protein concentration of CRP in the present CRM was determined by amino acid analysis coupled to isotope-dilution mass spectrometry (IDMS-AAA). To improve the accuracy of IDMS-AAA, we optimized the hydrolysis process by examining the effect of parameters such as the volume of protein samples taken for hydrolysis, the procedure of sample preparation prior to the hydrolysis, hydrolysis temperature, and hydrolysis time. Under optimized conditions, we conducted two independent approaches in which the following independent hydrolysis and liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) were combined: one was vapor-phase acid hydrolysis (130 °C, 24 h) and hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) method, and the other was microwave-assisted liquid-phase acid hydrolysis (150 °C, 3 h) and pre-column derivatization liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. The quantitative values of the two different amino acid analyses were in agreement within their uncertainties. The certified value was the weighted mean of the results of the two methods. Uncertainties from the value-assignment method, between-method variance, homogeneity, long-term stability, and short-term stability were taken into account in evaluating the uncertainty for a certified value. The certified value and the expanded uncertainty (k = 2) of CRM 6201-b are (40.0 ± 1.6) μmol kg(-1).
USDA-ARS?s Scientific Manuscript database
Establishing standards for meat tenderness based on Warner-Bratzler shear force (WBSF) is complicated by the lack of methods for certifying WBSF testing among texture systems or laboratories. The objective of this study was to determine the suitability of using gelatin gels as a reference material ...
Preparation and certification of Re-Os dating reference materials: Molybdenites HLP and JDC
Du, A.; Wu, S.; Sun, D.; Wang, Shaoming; Qu, W.; Markey, R.; Stain, H.; Morgan, J.; Malinovskiy, D.
2004-01-01
Two Re-Os dating reference material molybdenites were prepared. Molybdenite JDC and molybdenite HLP are from a carbonate vein-type molybdenum-(lead)- uranium deposit in the Jinduicheng-Huanglongpu area of Shaanxi province, China. The samples proved to be homogeneous, based on the coefficient of variation of analytical results and an analysis of variance test. The sampling weight was 0.1 g for JDC and 0.025 g for HLP. An isotope dilution method was used for the determination of Re and Os. Sample decomposition and preconcentration of Re and Os prior to measurement were accomplished using a variety of methods: acid digestion, alkali fusion, ion exchange and solvent extraction. Negative thermal ionisation mass spectrometry and inductively coupled plasma-mass spectrometry were used for the determination of Re and 187Os concentration and isotope ratios. The certified values include the contents of Re and Os and the model ages. For HLP, the Re content was 283.8 ?? 6.2 ??g g-1, 187Os was 659 ?? 14 ng g-1 and the Re-Os model age was 221.4 ?? 5.6 Ma. For JDC, the Re content was 17.39 ?? 0.32 ng g-1, 187Os was 25.46 ?? 0.60 ng g-1 and the Re-Os model age was 139.6 ?? 3.8 Ma. Uncertainties for both certified reference materials are stated at the 95% level of confidence. Three laboratories (from three countries: P.R. China, USA, Sweden) joined in the certification programme. These certified reference materials are primarily useful for Re-Os dating of molybdenite, sulfides, black shale, etc.
... Direct bilirubin - urine Images Male urinary system References Berk PD, Korenblat KM. Approach to the patient with ... Review Date 5/21/2017 Updated by: Laura J. Martin, MD, MPH, ABIM Board Certified in Internal ...
... Renal cell carcinoma Alternative Names Alkaline phosphatase References Berk PD, Korenblat KM. Approach to the patient with ... Review Date 5/21/2017 Updated by: Laura J. Martin, MD, MPH, ABIM Board Certified in Internal ...
... Alkaline phosphatase isoenzyme test Images Blood test References Berk PD, Korenblat KM. Approach to the patient with ... Review Date 5/21/2017 Updated by: Laura J. Martin, MD, MPH, ABIM Board Certified in Internal ...
Gawlik, B M; Lamberty, A; Pauwels, J; Blum, W E H; Mentler, A; Bussian, B; Eklo, O; Fox, K; Kördel, W; Hennecke, D; Maurer, T; Perrin-Ganier, C; Romero-Taboada, E; Szabo, G; Muntau, H
2003-08-01
IRMM-443 re-groups a set of six European Reference Soils (EUROSOILS), which had been certified for their adsorption coefficients for atrazine, 2,4-D and lindane (Certification of the European Reference Soil Set (IRMM-443-EUROSOILS)-Part I. Adsorption coefficients for atrazine, 2,4-D and lindane. Sci Total Environ, in press). The certification of these parameters was complemented by an additional certification of pH in suspension as well by the determination of indicative values for total nitrogen, organic and total carbon content. While Part I explained the principles of the value assignment process and discussed their application to the adsorption coefficients, Part II presents the certified values for pH as well as the indicative values for N(tot), C(tot) and C(org). In addition, the assessment of uncertainty components for stability and homogeneity, which have been included in the final uncertainty budget, is discussed.
Prendergast, Jocelyn L; Sniegoski, Lorna T; Welch, Michael J; Phinney, Karen W
2010-07-01
The definitive method (DM), now known as the reference measurement procedure (RMP), for the analysis of glucose in serum was originally published in 1982 by the National Institute of Standards and Technology (NIST). Over the years the method has been subject to a number of modifications to adapt to newer technologies and simplify sample preparation. We discuss here an adaptation of the method associated with serum glucose measurements using a modified isotope dilution gas chromatography/mass spectrometry (ID-GC/MS) method. NIST has used this modified method to certify the concentrations of glucose in SRM 965b, Glucose in Frozen Human Serum, and SRM 1950, Metabolites in Human Plasma. Comparison of results from the revised method with certified values for existing Standard Reference Materials (SRMs) demonstrated that these modifications have not affected the quality of the measurements, giving both good precision and accuracy, while reducing the sample preparation time by a day and a half.
Takahashi, Kayori; Kishine, Kana; Matsuyama, Shigetomo; Saito, Takeshi; Kato, Haruhisa; Kinugasa, Shinichi
2008-07-01
Poly(ethylene glycol) (PEG) is a useful water-soluble polymer that has attracted considerable interest in medical and biological science applications as well as in polymer physics. Through the use of a well-calibrated evaporative light-scattering detector coupled with high performance supercritical fluid chromatography, we are able to determine exactly not only the average mass but also all of the molecular mass fractions of PEG samples needed for certified reference materials issued by the National Metrology Institute of Japan. In addition, experimental uncertainty was determined in accordance with the Guide to the expression of uncertainty in measurement (GUM). This reference material can be used to calibrate measuring instruments, to control measurement precision, and to confirm the validity of measurement methods when determining molecular mass distributions and average molecular masses. Especially, it is suitable for calibration against both masses and intensities for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
Smallholder Participation and Certification of Organic Farm Products in Mexico
ERIC Educational Resources Information Center
Gonzalez, Alma Amalia; Nigh, Ronald
2005-01-01
Organic and other environmental and social marketing devices seek to connect producers and consumers more directly and reward environmentally and socially superior production systems. Some researchers have observed that these schemes may introduce mechanisms of exclusion, creating an elite group of certified smallholders while putting…
47 CFR 0.131 - Functions of the Bureau.
Code of Federal Regulations, 2012 CFR
2012-10-01
... infrastructure and the integration of wireless communications networks into the public telecommunications network...) Exercises such authority as may be assigned, delegated or referred to it by the Commission. (m) Certifies...
NASA Astrophysics Data System (ADS)
Noojipady, Praveen; Morton, Douglas C.; Schroeder, Wilfrid; Carlson, Kimberly M.; Huang, Chengquan; Gibbs, Holly K.; Burns, David; Walker, Nathalie F.; Prince, Stephen D.
2017-08-01
Indonesia and Malaysia have emerged as leading producers of palm oil in the past several decades, expanding production through the conversion of tropical forests to industrial plantations. Efforts to produce sustainable
palm oil, including certification by the Roundtable on Sustainable Palm Oil (RSPO), include guidelines designed to reduce the environmental impact of palm oil production. Fire-driven deforestation is prohibited by law in both countries and a stipulation of RSPO certification, yet the degree of environmental compliance is unclear, especially during El Niño events when drought conditions increase fire risk. Here, we used time series of satellite data to estimate the spatial and temporal patterns of fire-driven deforestation on and around oil palm plantations. In Indonesia, fire-driven deforestation accounted for one-quarter of total forest losses on both certified and noncertified plantations. After the first plantations in Indonesia received RSPO certification in 2009, forest loss and fire-driven deforestation declined on certified plantations but did not stop altogether. Oil palm expansion in Malaysia rarely involved fire; only 5 % of forest loss on certified plantations had coincident active fire detections. Interannual variability in fire detections was strongly influenced by El Niño and the timing of certification. Fire activity during the 2002, 2004, and 2006 El Niño events was similar among oil palm plantations in Indonesia that would later become certified, noncertified plantations, and surrounding areas. However, total fire activity was 75 % and 66 % lower on certified plantations than noncertified plantations during the 2009 and 2015 El Niño events, respectively. The decline in fire activity on certified plantations, including during drought periods, highlights the potential for RSPO certification to safeguard carbon stocks in peatlands and remaining forests in accordance with legislation banning fires. However, aligning certification standards with satellite monitoring capabilities will be critical to realize sustainable palm oil production and meet industry commitments to zero deforestation.
NASA Technical Reports Server (NTRS)
Noojipady, Praveen; Morton, Douglas C.; Schroeder, Wilfrid; Carlson, Kimberly M.; Huang, Chengquan; Gibbs, Holly K.; Burns, David; Walker, Nathalie F.; Prince, Stephen D.
2017-01-01
Indonesia and Malaysia have emerged as leading producers of palm oil in the past several decades, expanding production through the conversion of tropical forests to industrial plantations. Efforts to produce "sustainable" palm oil, including certification by the Roundtable on Sustainable Palm Oil (RSPO), include guidelines designed to reduce the environmental impact of palm oil production. Fire-driven deforestation is prohibited by law in both countries and a stipulation of RSPO certification, yet the degree of environmental compliance isunclear, especially during El Niño events when drought conditions increase fire risk. Here, we used time series of satellite data to estimate the spatial and temporal patterns of fire-driven deforestation on and around oil palm plantations. In Indonesia, fire-driven deforestation accounted for one-quarter of total forest losses on both certified and noncertified plantations. After the first plantations in Indonesia received RSPO certification in 2009,forest loss and fire-driven deforestation declined on certified plantations but did not stop altogether. Oil palm expansion in Malaysia rarely involved fire; only 5 % of forest loss on certified plantations had coincident activefire detections. Interannual variability in fire detections was strongly influenced by El Nino and the timing of certification. Fire activity during the 2002, 2004, and 2006 El Nino events was similar among oil palm plantations in Indonesia that would later become certified, noncertified plantations, and surrounding areas. However, total fire activity was 75% and 66% lower on certified plantations than noncertified plantations during the 2009 and 2015 El Nino events, respectively. The decline in fire activity on certified plantations, including during drought periods, highlights the potential for RSPO certification to safeguard carbon stocks in peatlands and remaining forests in accordance with legislation banning fires. However, aligning certification standards with satellite monitoring capabilities will be critical to realize sustainable palm oil production and meet industry commitments to zero forestation.
Neves, Laura A; Rodrigues, Janaína M; Daroda, Romeu J; Silva, Paulo R M; Ferreira, Alexandre A; Aranda, Donato A G; Eberlin, Marcos N; Fasciotti, Maíra
2015-11-15
Brazil is the largest producer of sugar cane bioethanol in the world. Isotope ratio mass spectrometry (IRMS) is the technique of choice to certify the origin/raw materials for ethanol production, but the lack of certified reference materials (CRMs) for accurate measurements of δ(13) C values traceable to Vienna Pee Dee Belemnite (VPDB), the international zero point for (13) C/(12) C measurements, certified and compatible with gas chromatography (GC)/IRMS instruments may compromise the accuracy of δ(13) C determinations. We evaluated the influence of methods for the calibration and normalization of raw δ(13) C values of ethanol samples. Samples were analyzed by GC/C/IRMS using two different GC columns. Different substances were used as isotopic standards for the working gas calibration. The δ(13) C values obtained with the three methods of normalization were statistically compared with those obtained with elemental analyzer (EA)/IRMS, since the δ(13) C results obtained using EA are traceable to VPDB via the NBS 22 reference material. It was observed that both the isotopic reference material for CO2 calibration and the GC column have a major effect on the δ(13) C measurements, leading to a bias of almost 2-3 ‰ in the δ(13) C values. All three methods of normalization were equivalent in performance, enabling an improvement in the GC/C/IRMS accuracy, compared with the EA/IRMS reference values for the samples. All the methods of CO2 calibration, chromatography and normalization presented in this work demonstrated several sources of traceability and accuracy loss for the determination of δ(13) C values in ethanol fuel samples by GC/C/IRMS. This work has also shown the importance of using proper CRMs traceable to VPBD that should be compatible and certified using GC/C/IRMS, ideally in a wide range of δ(13) C values. This is important not only for bioethanol fuel samples, but also for many analytes commonly analyzed by IRMS. Copyright © 2015 John Wiley & Sons, Ltd.
75 FR 43801 - Airworthiness Directives; Eurocopter France (ECF) Model EC225LP Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-27
... time. Also, we use inspect rather than check when referring to an action required by a mechanic as... the various levels of government. Therefore, I certify this AD: 1. Is not a ``significant regulatory... compliance time. Also, we use inspect rather than check when referring to an action required by a mechanic as...
ERIC Educational Resources Information Center
Martin, Maria Mathilde
2004-01-01
When a university acquires the library of a national institute and the institute's active and worldwide membership expects continued and uninterrupted access to services from the collection, shockwaves can reverberate throughout the university's main library and among its staff. This was especially true for the Reference Department of the…
Crop Science. Instructor Guide [and] Student Reference. Volume 24, Numbers 5 and 6.
ERIC Educational Resources Information Center
Humphrey, John Kevin
This document consists of two separately published guides for a course on crop science: an instructor's guide and a student's reference manual. Each part contains nine lessons on the following topics: (1) economic importance of crops; (2) crop uses (products and byproducts); (3) plant and seed identification; (4) certified seed and variety…
Stefaniak, Aleksandr B; Hackley, Vincent A; Roebben, Gert; Ehara, Kensei; Hankin, Steve; Postek, Michael T; Lynch, Iseult; Fu, Wei-En; Linsinger, Thomas P J; Thünemann, Andreas F
2013-12-01
The authors critically reviewed published lists of nano-objects and their physico-chemical properties deemed important for risk assessment and discussed metrological challenges associated with the development of nanoscale reference materials (RMs). Five lists were identified that contained 25 (classes of) nano-objects; only four (gold, silicon dioxide, silver, titanium dioxide) appeared on all lists. Twenty-three properties were identified for characterisation; only (specific) surface area appeared on all lists. The key themes that emerged from this review were: 1) various groups have prioritised nano-objects for development as "candidate RMs" with limited consensus; 2) a lack of harmonised terminology hinders accurate description of many nano-object properties; 3) many properties identified for characterisation are ill-defined or qualitative and hence are not metrologically traceable; 4) standardised protocols are critically needed for characterisation of nano-objects as delivered in relevant media and as administered to toxicological models; 5) the measurement processes being used to characterise a nano-object must be understood because instruments may measure a given sample in a different way; 6) appropriate RMs should be used for both accurate instrument calibration and for more general testing purposes (e.g., protocol validation); 7) there is a need to clarify that where RMs are not available, if "(representative) test materials" that lack reference or certified values may be useful for toxicology testing and 8) there is a need for consensus building within the nanotechnology and environmental, health and safety communities to prioritise RM needs and better define the required properties and (physical or chemical) forms of the candidate materials.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-13
...EPA is taking final action to approve the December 10, 2007, submission by the State of Alabama, through the Alabama Department of Environmental Management (ADEM) as demonstrating that the State meets the state implementation plan (SIP) requirements of sections 110(a)(1) and (2) of the Clean Air Act (CAA or the Act) for the 1997 8-hour ozone national ambient air quality standards (NAAQS). Section 110(a) of the CAA requires that each state adopt and submit a SIP for the implementation, maintenance, and enforcement of each NAAQS promulgated by the EPA, which is commonly referred to as an ``infrastructure'' SIP. Alabama certified that the Alabama SIP contains provisions that ensure the 1997 8-hour ozone NAAQS is implemented, enforced, and maintained in Alabama (hereafter referred to as ``infrastructure submission''). Alabama's infrastructure submission, provided to EPA on December 10, 2007, addressed all the required infrastructure elements for the 1997 8-hour ozone NAAQS. Additionally, EPA is responding to adverse comments received on EPA's March 17, 2011, proposed approval of Alabama's December 10, 2007, infrastructure submission.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-13
...EPA is taking final action to approve the December 7, 2007, submission by the State of Mississippi, through the Mississippi Department of Environmental Quality (MDEQ) as demonstrating that the State meets the implementation plan (SIP) requirements of sections 110(a)(1) and (2) of the Clean Air Act (CAA or the Act) for the 1997 8- hour ozone national ambient air quality standards (NAAQS). Section 110(a) of the CAA requires that each state adopt and submit a SIP for the implementation, maintenance, and enforcement of each NAAQS promulgated by the EPA, which is commonly referred to as an ``infrastructure'' SIP. Mississippi certified that the Mississippi SIP contains provisions that ensure the 1997 8-hour ozone NAAQS is implemented, enforced, and maintained in Mississippi (hereafter referred to as ``infrastructure submission''). Mississippi's infrastructure submission, provided to EPA on December 7, 2007, addressed all the required infrastructure elements for the 1997 8-hour ozone NAAQS. Additionally, EPA is responding to adverse comments received on EPA's March 17, 2011, proposed approval of Mississippi's December 7, 2007, infrastructure submission.
Olson, John; Adamic, Mary; Snyder, Darin; Brookhart, Jacob; Hahn, Paula; Watrous, Matthew
2017-08-01
Iodine environmental measurements have consistently been validated in the literature using the standard material IAEA-375, soil collected approximately 160 miles northeast of Chernobyl, which is currently the only soil/sediment material with a certified 129 I activity. IAEA-375 has not been available for purchase since approximately 2010. Two other standard materials that are available (NIST SRM 4354, freshwater lake sediment and NIST SRM 4357, ocean sediment) have certified activities for a variety of radionuclides but not for 129 I. This paper reports a comparison of TIMS and AMS data for all three standards. Copyright © 2017. Published by Elsevier Ltd.
C-TEC: Ohio's First All-Green School
ERIC Educational Resources Information Center
Krall, Angie
2009-01-01
In Ohio's Licking County, the Career and Technology Education Centers (C-TEC) is a leader in the green movement. This eco-friendly school incorporates environmental sustainability in all aspects of its programming and is the first Leadership in Energy and Environmental Design (LEED)-certified public building in the state. While eco-friendly…
2010-08-01
2009; Williams et al.. 2010), and a reference dose (RfD) of 3 IJg/kg-day based on prostatic inflammation in rodents. RDX is also classified as a...cycle (USACHPPM., 2006). A certified pesticide-free rodent chow (Harlan Teklad®, 8728C Certified Rodent Diet ) and drinking quality tap water were...K, CI Analyzer, IDEXX Laboratories, Inc., One IDEXX Drive, Westbrook, ME 04092): albumin (ALB), alkaline phosphatase (ALK P), alanine
Rucandio, M Isabel; Petit-Domínguez, M Dolores
2002-01-01
Cadmium is a representative example of trace elements that are insidious and widespread health hazards. In contemporary environmental analysis, there is a clear trend toward its determination over a wide range of concentrations in complex matrixes. This paper describes a versatile method for the determination of Cd at various levels (0.1-500 microg/g) in several sample types, such as soils, sediments, coals, ashes, sewage sludges, animal tissues, and plants, by graphite furnace atomic absorption spectrometry with Zeeman background correction. The effect of the individual presence of about 50 elements, with an interference/analyte concentration ratio of up to 10(5), was tested; recoveries of Cd ranged from 93 to 106%. The influence of different media, such as HNO3, HCI, HF, H2SO4, HClO4, acetic acid, hydroxylammonium chloride, and ammonium acetate, in several concentrations, was also tested. From these studies it can be concluded that the analytical procedure is scarcely matrix dependent, and the results obtained for a wide diversity of reference materials are in good agreement with the certified values.
... window sills . EPA has two programs for certifying contractors and accrediting training providers Renovation, Repair and Painting ... to for activities in your community. Report Uncertified Contractors and Environmental Violations Popular Topics and Resources Newsroom ...
Thomas, Vernon G; Hanner, Robert H; Borisenko, Alex V
2016-11-01
Managing invasive alien species in Canada requires reliable taxonomic identification as the basis of rapid-response management. This can be challenging, especially when organisms are small and lack morphological diagnostic features. DNA-based techniques, such as DNA barcoding, offer a reliable, rapid, and inexpensive toolkit for taxonomic identification of individual or bulk samples, forensic remains, and even environmental DNA. Well suited for this requirement, they could be more broadly deployed and incorporated into the operating policy and practices of Canadian federal departments and should be authorized under these agencies' articles of law. These include Fisheries and Oceans Canada, Canadian Food Inspection Agency, Transport Canada, Environment Canada, Parks Canada, and Health Canada. These efforts should be harmonized with the appropriate provisions of provincial jurisdictions, for example, the Ontario Invasive Species Act. This approach necessitates that a network of accredited, certified laboratories exists, and that updated DNA reference libraries are readily accessible. Harmonizing this approach is vital among Canadian federal agencies, and between the federal and provincial levels of government. Canadian policy and law must also be harmonized with that of the USA when detecting, and responding to, invasive species in contiguous lands and waters. Creating capacity in legislation for use of DNA-based identifications brings the authority to fund, train, deploy, and certify staff, and to refine further developments in this molecular technology.
2010-01-01
Background The Worldwide Antimalarial Resistance Network (WWARN) is a global collaboration to support the objective that anyone affected by malaria receives effective and safe drug treatment. The Pharmacology module aims to inform optimal anti-malarial drug selection. There is an urgent need to define the drug exposure - effect relationship for most anti-malarial drugs. Few anti-malarials have had their therapeutic blood concentration levels defined. One of the main challenges in assessing safety and efficacy data in relation to drug concentrations is the comparability of data generated from different laboratories. To explain differences in anti-malarial pharmacokinetics in studies with different measurement laboratories it is necessary to confirm the accuracy of the assay methods. This requires the establishment of an external quality assurance process to assure results that can be compared. This paper describes this process. Methods The pharmacology module of WWARN has established a quality assurance/quality control (QA/QC) programme consisting of two separate components: 1. A proficiency testing programme where blank human plasma spiked with certified reference material (CRM) in different concentrations is sent out to participating bioanalytical laboratories. 2. A certified reference standard programme where accurately weighed amounts of certified anti-malarial reference standards, metabolites, and internal standards are sent to participating bioanalytical and in vitro laboratories. Conclusion The proficiency testing programme is designed as a cooperative effort to help participating laboratories assess their ability to carry out drug analysis, resolve any potential problem areas and to improve their results - and, in so doing, to improve the quality of anti-malarial pharmacokinetic data published and shared with WWARN. By utilizing the same source of standards for all laboratories, it is possible to minimize bias arising from poor quality reference standards. By providing anti-malarial drug standards from a central point, it is possible to lower the cost of these standards. PMID:21184684
Poperechna, Nataliya; Heumann, Klaus G
2005-09-01
An accurate and sensitive multi-species species-specific isotope dilution GC-ICP-MS method was developed for the simultaneous determination of trimethyllead (Me3Pb+), monomethylmercury (MeHg+) and the three butyltin species Bu3Sn+, Bu2Sn2+, and BuSn3+ in biological samples. The method was validated by three biological reference materials (CRM 477, mussel tissue certified for butyltins; CRM 463, tuna fish certified for MeHg+; DORM 2, dogfish muscle certified for MeHg+). Under certain conditions, and with minor modifications of the sample pretreatment procedure, this method could also be transferred to environmental samples such as sediments, as demonstrated by analyzing sediment reference material BCR 646 (freshwater sediment, certified for butyltins). The detection limits of the multi-species GC-ICP-IDMS method for biological samples were 1.4 ng g(-1) for MeHg+, 0.06 ng g(-1) for Me3Pb+, 0.3 ng g(-1) for BuSn3+ and Bu3Sn+, and 1.2 ng g(-1) for Bu2Sn2+. Because of the high relevance of these heavy metal alkyl species to the quality assurance of seafood, the method was also applied to corresponding samples purchased from a supermarket. The methylated lead fraction in these samples, correlated to total lead, varied over a broad range (from 0.01% to 7.6%). On the other hand, the MeHg+ fraction was much higher, normally in the range of 80-100%. Considering that we may expect tighter legislative limitations on MeHg+ levels in seafood in the future, we found the highest methylmercury contents (up to 10.6 microg g(-1)) in two shark samples, an animal which is at the end of the marine food chain, whereas MeHg+ contents of less than 0.2 microg g(-1) were found in most other seafood samples; these results correlate with the idea that MeHg+ is usually of biological origin in the marine environment. The concentration of butyltins and the fraction of the total tin content that is from butyltins strongly depend on possible contamination, due to the exclusively anthropogenic character of these compounds. A broad variation in the butylated tin fraction (in the range of <0.3-49%) was therefore observed in different seafood samples. Corresponding isotope-labeled spike compounds (except for trimethyllead) are commercially available for all of these compounds, and since these can be used in the multi-species species-specific GC-ICP-IDMS method developed here, this technique shows great potential for routine analysis in the future.
Zhu, Yanbei; Narukawa, Tomohiro; Miyashita, Shin-ichi; Kuroiwa, Takayoshi; Inagaki, Kazumi; Chiba, Koichi; Hioki, Akiharu
2013-01-01
A certified reference material (CRM), NMIJ CRM 7512-a, was developed for the determination of trace elements in milk powder. At least three independent analytical methods were applied to characterize the certified value of each element; all of these analytical methods were based on microwave acid digestions and carried out using different analytical instruments. The certified value was given on a dry-mass basis, where the dry-mass correction factor was obtained by drying the sample at 65°C for 15 to 25 h. The certified values in the units of mass fractions for 13 elements were as follows: Ca, 8.65 (0.38) g kg(-1); Fe, 0.104 (0.007) g kg(-1); K, 8.41 (0.33) g kg(-1); Mg, 0.819 (0.024) g kg(-1); Na, 1.87 (0.09) g kg(-1); P, 5.62 (0.23) g kg(-1); Ba, 0.449 (0.013) mg kg(-1); Cu, 4.66 (0.23) mg kg(-1); Mn, 0.931 (0.032) mg kg(-1); Mo, 0.223 (0.012) mg kg(-1); Rb, 8.93 (0.31) mg kg(-1); Sr, 5.88 (0.20) mg kg(-1); and Zn, 41.3 (1.4) mg kg(-1), where the numbers in the parentheses are the expanded uncertainties with a coverage factor of 2. The expanded uncertainties were estimated considering the contribution of the analytical methods, the method-to-method variance, the sample homogeneity, the dry-mass correction factor, and the concentrations of the standard solutions for calibration. The concentrations of As (2.1 μg kg(-1)), Cd (0.2 μg kg(-1)), Cr (1.3 μg kg(-1)), Pb (0.3 μg kg(-1)), and Y (64 μg kg(-1)) were given as information values for the present CRM.
Bahlai, Christine A; Xue, Yingen; McCreary, Cara M; Schaafsma, Arthur W; Hallett, Rebecca H
2010-06-22
Selection of pesticides with small ecological footprints is a key factor in developing sustainable agricultural systems. Policy guiding the selection of pesticides often emphasizes natural products and organic-certified pesticides to increase sustainability, because of the prevailing public opinion that natural products are uniformly safer, and thus more environmentally friendly, than synthetic chemicals. We report the results of a study examining the environmental impact of several new synthetic and certified organic insecticides under consideration as reduced-risk insecticides for soybean aphid (Aphis glycines) control, using established and novel methodologies to directly quantify pesticide impact in terms of biocontrol services. We found that in addition to reduced efficacy against aphids compared to novel synthetic insecticides, organic approved insecticides had a similar or even greater negative impact on several natural enemy species in lab studies, were more detrimental to biological control organisms in field experiments, and had higher Environmental Impact Quotients at field use rates. These data bring into caution the widely held assumption that organic pesticides are more environmentally benign than synthetic ones. All pesticides must be evaluated using an empirically-based risk assessment, because generalizations based on chemical origin do not hold true in all cases.
12 CFR 1010.506 - State/Federal filing requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... referring to that section and page of the material which is being amended, and; (ii) A signed state.... No action need be taken by the Director to effect the suspension. (g) A state is certified only with...
12 CFR 1010.506 - State/Federal filing requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... referring to that section and page of the material which is being amended, and; (ii) A signed state.... No action need be taken by the Director to effect the suspension. (g) A state is certified only with...
9 CFR 355.32 - Labeling required.
Code of Federal Regulations, 2014 CFR
2014-01-01
... CERTIFICATION CERTIFIED PRODUCTS FOR DOGS, CATS, AND OTHER CARNIVORA; INSPECTION, CERTIFICATION, AND... such as “dog food,” “cat food,” “dog and cat food,” or “fox food,” accompanied with such references to...
9 CFR 355.32 - Labeling required.
Code of Federal Regulations, 2013 CFR
2013-01-01
... CERTIFICATION CERTIFIED PRODUCTS FOR DOGS, CATS, AND OTHER CARNIVORA; INSPECTION, CERTIFICATION, AND... such as “dog food,” “cat food,” “dog and cat food,” or “fox food,” accompanied with such references to...
9 CFR 355.32 - Labeling required.
Code of Federal Regulations, 2012 CFR
2012-01-01
... CERTIFICATION CERTIFIED PRODUCTS FOR DOGS, CATS, AND OTHER CARNIVORA; INSPECTION, CERTIFICATION, AND... such as “dog food,” “cat food,” “dog and cat food,” or “fox food,” accompanied with such references to...
9 CFR 355.32 - Labeling required.
Code of Federal Regulations, 2011 CFR
2011-01-01
... CERTIFICATION CERTIFIED PRODUCTS FOR DOGS, CATS, AND OTHER CARNIVORA; INSPECTION, CERTIFICATION, AND... such as “dog food,” “cat food,” “dog and cat food,” or “fox food,” accompanied with such references to...
9 CFR 355.32 - Labeling required.
Code of Federal Regulations, 2010 CFR
2010-01-01
... CERTIFICATION CERTIFIED PRODUCTS FOR DOGS, CATS, AND OTHER CARNIVORA; INSPECTION, CERTIFICATION, AND... such as “dog food,” “cat food,” “dog and cat food,” or “fox food,” accompanied with such references to...
Bréas, Olivier; Thomas, Freddy; Zeleny, Reinhard; Calderone, Giovanni; Jamin, Eric; Guillou, Claude
2007-01-01
Tetramethylurea (TMU) with a certified D/H ratio is the internal standard for Site-specific Natural Isotope Fractionation measured by Nuclear Magnetic Resonance (SNIF-NMR) analysis of wine ethanol for detection of possible adulterations (Commission Regulation 2676/90). A new batch of a TMU certified reference material (CRM) is currently being prepared. Whereas SNIF-NMR has been employed up to now, Elemental Analysis/Isotope Ratio Mass Spectrometry ((2)H-EA-IRMS) was envisaged as the method of choice for value assignment of the new CRM, as more precise (better repeatable) data might be obtained, resulting in lower uncertainty of the certified value. In order to evaluate the accuracy and intra- and inter-laboratory reproducibility of (2)H-EA-IRMS methods, a laboratory inter-comparison was carried out by analysing TMU and other organic compounds, as well as some waters. The results revealed that experienced laboratories are capable of generating robust and well comparable data, which highlights the emerging potential of IRMS in food authenticity testing. However, a systematic bias between IRMS and SNIF-NMR reference data was observed for TMU; this lack of data consistency rules out the (2)H-IRMS technique for the characterisation measurement of the new TMU CRM.
Beach, Daniel G; Crain, Sheila; Lewis, Nancy; LeBlanc, Patricia; Hardstaff, William R; Perez, Ruth A; Giddings, Sabrina D; Martinez-Farina, Camilo F; Stefanova, Roumiana; Burton, Ian W; Kilcoyne, Jane; Melanson, Jeremy E; Quilliam, Michael A; McCarron, Pearse
2016-09-01
Okadaic acid (OA) and its analogs dinophysistoxins-1 (DTX1) and -2 (DTX2) are lipophilic polyethers produced by marine dinoflagellates. These toxins accumulate in shellfish and cause diarrhetic shellfish poisoning (DSP) in humans. Regulatory testing of shellfish is essential to safeguard public health and for international trade. Certified reference materials (CRMs) play a key role in analytical monitoring programs. This paper presents an overview of the interdisciplinary work that went into the planning, production, and certification of calibration-solution CRMs for OA, DTX1, and DTX2. OA and DTX1 were isolated from large-scale algal cultures and DTX2 from naturally contaminated mussels. Toxins were isolated by a combination of extraction and chromatographic steps with processes adapted to suit the source and concentration of each toxin. New 19-epi-DSP toxin analogs were identified as minor impurities. Once OA, DTX1, and DTX2 were established to be of suitable purity, solutions were prepared and dispensed into flame-sealed glass ampoules. Certification measurements were carried out using quantitative NMR spectroscopy and LC-tandem MS. Traceability of measurements was established through certified external standards of established purity. Uncertainties were assigned following standards and guidelines from the International Organization for Standardization, with components from the measurement, stability, and homogeneity studies being propagated into final combined uncertainties.
Su, Shaowei; Chen, Beibei; He, Man; Hu, Bin; Xiao, Zuowei
2014-02-01
A novel Fe3O4@SiO2@polyaniline-graphene oxide composite (MPANI-GO) was prepared through a simple noncovalent method and applied to magnetic solid phase extraction (MSPE) of trace rare earth elements (REEs) in tea leaves and environmental water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. The prepared MPANI-GO was characterized by transmission electron microscopy and vibrating sample magnetometer. Various parameters affecting MPANI-GO MSPE of REEs have been investigated. Under the optimized conditions, the limits of detection (LODs, 3σ) for REEs were in the range of 0.04-1.49 ng L(-1) and the relative standard deviations (RSDs, c=20 ng L(-1), n=7) were 1.7-6.5%. The accuracy of the proposed method was validated by analyzing a Certified Reference Material of GBW 07605 tea leaves. The method was also successfully applied for the determination of trace REEs in tea leaves and environmental water samples. The developed MPANI-GO MSPE-ICP-MS method has the advantages of simplicity, rapidity, high sensitivity, high enrichment factor and is suitable for the analysis of trace REEs in samples with complex matrix. © 2013 Elsevier B.V. All rights reserved.
Synthetic musk fragrances in environmental Standard Reference Materials.
Peck, Aaron M; Kucklick, John R; Schantz, Michele M
2007-04-01
Synthetic musk fragrances have been measured in water, air, sediments, sewage sludge, and biota worldwide. As the study of the environmental fate and impacts of these compounds progresses, the need for Standard Reference Materials (SRMs) for these compounds to facilitate analytical method improvement and interlaboratory comparisons becomes increasingly important. The National Institute of Standards and Technology (NIST) issues environmental matrix SRMs with certified concentrations for a variety of persistent organic pollutants including polycyclic aromatic hydrocarbons (PAHs), chlorinated pesticides, and polychlorinated biphenyl congeners (PCBs). Until now synthetic musk fragrance concentrations have not been reported in NIST SRMs. The objective of this study was to provide reference values for several commonly detected synthetic musk fragrances in several NIST natural matrix SRMs. In this study five polycyclic musk fragrances [HHCB (1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethylcyclopenta-gamma-2-benzopyran), AHTN (7-acetyl-1,1,3,4,4,6-hexamethyl-1,2,3,4-tetrahydronaphthalene), ADBI (4-acetyl-1,1-dimethyl-6-tert-butylindane), AHMI (6-acetyl-1,1,2,3,3,5-hexamethylindane), and ATII (5-acetyl-1,1,2,6-tetramethyl-3-isopropylindane] and two nitro musk fragrances [musk xylene (1-tert-butyl-3,5-dimethyl-2,4,6-trinitrobenzene) and musk ketone (4-tert-butyl-3,5-dinitro-2,6-dimethylacetophenone)] were measured in selected environmental SRMs. Gas chromatography-electron impact mass spectrometry (GC/EI-MS) was used for all analyses. HHCB was the most frequently detected synthetic musk fragrance and was detected in SRM 2585 Organic Contaminants in House Dust, SRM 2781 Domestic Sludge, SRM 1974b Organics in Mussel Tissue (Mytilus edulis), and SRM 1947 Lake Michigan Fish Tissue. It was not detected in SRM 1946 Lake Superior Fish Tissue or SRM 1945 Organics in Whale Blubber. Concentrations of HHCB in these SRMs ranged from 1.12 ng/g in SRM 1947 to 92,901 ng/g in SRM 2781. All of the polycyclic musk fragrances were detected in SRM 2781 and all of the target compounds were detected in SRM 2585.
Faucher, Stéphane; Cugnet, Cyril; Authier, Laurent; Lespes, Gaëtane
2014-02-01
The objective of the study is to evaluate modified-carbon screen-printed working electrodes (SPE) combined with square wave anodic stripping voltammetry (SWASV) to determine electrolabile and total copper in soils with the perspective to assess the environmental hazard resulting from copper anthropogenic contamination. The voltammetric method was investigated using a mineralized certified reference soil such that it can be assumed that the copper was totally under electrolabile form in the solution of mineralized soil. In optimal conditions, a copper recovery of 97% and a relative standard deviation (RSD) of 9% were found. The limits of detection and quantification for copper were 0.4 and 1.3 μg L(-1), respectively. Finally, the method was applied on soil leachates, which allowed evaluating the cupric transfer from the soil to the leachates and quantifying the electrolabile copper part in leachates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willie, S.
1997-12-01
A total of thirty-nine participants were included in the exercise, including OAA, USEPA, state, Australian, Canadian, Mexican and Argentinean laboratories. Two samples were sent by NRC to each participant, and contaminated marine sediment from Esquimalt harbor in British Columbia and a freeze-dried oyster tissue. Laboratories were also asked to analyze two certified reference materials (CRMs) MESS-2 and CRM 2976. The elements to be determined were Al, Cr, Fe, Ni, Cu, Zn, As, Se, Ag, Cd, Sn, Hg and Pb for both matrices, plus Be, Si, Mn, Sb and Tl for the sediments. An accepted mean and confidence interval was calculatedmore » for each analyte in the two unknown samples, laboratory biases were identified and an overall rating of superior, good, fair or others were assigned to each laboratory.« less
Role of modifiers for analytical-scale supercritical fluid extraction of environmental samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langenfeld, J.J.; Hawthorne, S.B.; Miller, D.J.
1994-03-15
Supercritical fluid extraction (SFE) using eight different CO[sub 2] + organic modifier mixtures and one ternary mixture (CO[sub 2] + methanol/toluene) at two different concentrations (1 and 10% v/v) was performed on two certified reference materials including polychlorinated biphenyls (PCBs) from river sediment and polycyclic aromatic hydrocarbons (PAHs) from urban air particulate matter. The modifier identity was more important than modifier concentration for increasing extraction efficiencies. Acidic/basic modifiers including methanol, acetic acid, and aniline greatly enhanced the extraction of PCBs. Low molecular weight PAHs were best extracted with modifiers including aniline, acetic acid, acetonitrile, methanol/toluene, hexane, and diethylamine. In contrast,more » modifiers capable of dipole-induced dipole interactions and [pi]-[pi] interactions such as toluene, diethylamine, and methylene chloride were the best modifiers to use for SFE of high molecular weight PAHs from air particulates. 37 refs., 6 tabs.« less
Le, Phuong-Mai; Ding, Jianfu; Leek, Donald M; Mester, Zoltan; Robertson, Gilles; Windust, Anthony; Meija, Juris
2016-10-01
In this study, we report the characterization of three arsenobetaine-certified reference materials by quantitative NMR. We have synthesized an arsenobetaine bromide high-purity standard of natural isotopic composition (ABET-1) and two carbon-13-labeled isotopic standards (BBET-1 and CBET-1). Assignments of the chemical purity and isotopic composition are not trivial in the case of arsenobetaine, and in this study we utilized quantitative(1)H-NMR techniques for the determination of the mass fractions (chemical purity). The isotopic purity of all three standards was also assessed by NMR from the carbon-13 satellite signals. The standards are non-hygroscopic, high-purity (ca. 0.99 g/g), and the carbon-13 enrichment for both isotopic standards is x((13)C)≈0.99. These standards are designed for use as primary calibrators for mass spectrometric determination of arsenobetaine in environmental samples.
Narin, Ibrahim; Surme, Yavuz; Bercin, Erdogan; Soylak, Mustafa
2007-06-25
In the presented work, alpha-benzoin oxime immobilized SP70 chelating resin was synthesized for separation and preconcentration of Pb(II), Cd(II), Co(II) and Cr(III). The optimization procedure for analytical parameters including pH, eluent type, flow rate, etc. was examined in order to gain quantitative recoveries of analyte ions. The effects of foreign ions on the recoveries of studied metal ions were also investigated. The detection limits (3sigma) were found to be 16.0, 4.2, 1.3, 2.4microgL(-1) for Pb, Cd, Co and Cr, respectively. The preconcentration factor was 75 for Pb, 100 for Cd, Co and Cr. The optimized method was validated with certified reference materials and successfully applied to the waters, crops and pharmaceutical samples with good results (recoveries greater than 95%, R.S.D. lower than 10%).
Eco-label conveys reliable information on fish stock health to seafood consumers.
Gutiérrez, Nicolás L; Valencia, Sarah R; Branch, Trevor A; Agnew, David J; Baum, Julia K; Bianchi, Patricia L; Cornejo-Donoso, Jorge; Costello, Christopher; Defeo, Omar; Essington, Timothy E; Hilborn, Ray; Hoggarth, Daniel D; Larsen, Ashley E; Ninnes, Chris; Sainsbury, Keith; Selden, Rebecca L; Sistla, Seeta; Smith, Anthony D M; Stern-Pirlot, Amanda; Teck, Sarah J; Thorson, James T; Williams, Nicholas E
2012-01-01
Concerns over fishing impacts on marine populations and ecosystems have intensified the need to improve ocean management. One increasingly popular market-based instrument for ecological stewardship is the use of certification and eco-labeling programs to highlight sustainable fisheries with low environmental impacts. The Marine Stewardship Council (MSC) is the most prominent of these programs. Despite widespread discussions about the rigor of the MSC standards, no comprehensive analysis of the performance of MSC-certified fish stocks has yet been conducted. We compared status and abundance trends of 45 certified stocks with those of 179 uncertified stocks, finding that 74% of certified fisheries were above biomass levels that would produce maximum sustainable yield, compared with only 44% of uncertified fisheries. On average, the biomass of certified stocks increased by 46% over the past 10 years, whereas uncertified fisheries increased by just 9%. As part of the MSC process, fisheries initially go through a confidential pre-assessment process. When certified fisheries are compared with those that decline to pursue full certification after pre-assessment, certified stocks had much lower mean exploitation rates (67% of the rate producing maximum sustainable yield vs. 92% for those declining to pursue certification), allowing for more sustainable harvesting and in many cases biomass rebuilding. From a consumer's point of view this means that MSC-certified seafood is 3-5 times less likely to be subject to harmful fishing than uncertified seafood. Thus, MSC-certification accurately identifies healthy fish stocks and conveys reliable information on stock status to seafood consumers.
Eco-Label Conveys Reliable Information on Fish Stock Health to Seafood Consumers
Gutiérrez, Nicolás L.; Valencia, Sarah R.; Branch, Trevor A.; Agnew, David J.; Baum, Julia K.; Bianchi, Patricia L.; Cornejo-Donoso, Jorge; Costello, Christopher; Defeo, Omar; Essington, Timothy E.; Hilborn, Ray; Hoggarth, Daniel D.; Larsen, Ashley E.; Ninnes, Chris; Sainsbury, Keith; Selden, Rebecca L.; Sistla, Seeta; Smith, Anthony D. M.; Stern-Pirlot, Amanda; Teck, Sarah J.; Thorson, James T.; Williams, Nicholas E.
2012-01-01
Concerns over fishing impacts on marine populations and ecosystems have intensified the need to improve ocean management. One increasingly popular market-based instrument for ecological stewardship is the use of certification and eco-labeling programs to highlight sustainable fisheries with low environmental impacts. The Marine Stewardship Council (MSC) is the most prominent of these programs. Despite widespread discussions about the rigor of the MSC standards, no comprehensive analysis of the performance of MSC-certified fish stocks has yet been conducted. We compared status and abundance trends of 45 certified stocks with those of 179 uncertified stocks, finding that 74% of certified fisheries were above biomass levels that would produce maximum sustainable yield, compared with only 44% of uncertified fisheries. On average, the biomass of certified stocks increased by 46% over the past 10 years, whereas uncertified fisheries increased by just 9%. As part of the MSC process, fisheries initially go through a confidential pre-assessment process. When certified fisheries are compared with those that decline to pursue full certification after pre-assessment, certified stocks had much lower mean exploitation rates (67% of the rate producing maximum sustainable yield vs. 92% for those declining to pursue certification), allowing for more sustainable harvesting and in many cases biomass rebuilding. From a consumer’s point of view this means that MSC-certified seafood is 3–5 times less likely to be subject to harmful fishing than uncertified seafood. Thus, MSC-certification accurately identifies healthy fish stocks and conveys reliable information on stock status to seafood consumers. PMID:22928029
40 CFR 62.7120 - Identification of plan-negative declaration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the Nevada Division of Environmental Protection submitted March 26, 1997 certifying that there are no... this chapter. [65 FR 33467, May 24, 2000] Emissions From Small Existing Municipal Waste Combustion...
42 CFR 493.913 - Mycobacteriology.
Code of Federal Regulations, 2012 CFR
2012-10-01
... purposes: (1) Those that interpret acid-fast stains and refer specimen to another laboratory appropriately certified in the subspecialty of mycobacteriology; (2) Those that interpret acid-fast stains, perform... of mycobacteriology for identification; (3) Those that interpret acid-fast stains, isolate and...
42 CFR 493.913 - Mycobacteriology.
Code of Federal Regulations, 2014 CFR
2014-10-01
... purposes: (1) Those that interpret acid-fast stains and refer specimen to another laboratory appropriately certified in the subspecialty of mycobacteriology; (2) Those that interpret acid-fast stains, perform... of mycobacteriology for identification; (3) Those that interpret acid-fast stains, isolate and...
42 CFR 493.913 - Mycobacteriology.
Code of Federal Regulations, 2013 CFR
2013-10-01
... purposes: (1) Those that interpret acid-fast stains and refer specimen to another laboratory appropriately certified in the subspecialty of mycobacteriology; (2) Those that interpret acid-fast stains, perform... of mycobacteriology for identification; (3) Those that interpret acid-fast stains, isolate and...
42 CFR 493.913 - Mycobacteriology.
Code of Federal Regulations, 2010 CFR
2010-10-01
... purposes: (1) Those that interpret acid-fast stains and refer specimen to another laboratory appropriately certified in the subspecialty of mycobacteriology; (2) Those that interpret acid-fast stains, perform... of mycobacteriology for identification; (3) Those that interpret acid-fast stains, isolate and...
42 CFR 493.913 - Mycobacteriology.
Code of Federal Regulations, 2011 CFR
2011-10-01
... purposes: (1) Those that interpret acid-fast stains and refer specimen to another laboratory appropriately certified in the subspecialty of mycobacteriology; (2) Those that interpret acid-fast stains, perform... of mycobacteriology for identification; (3) Those that interpret acid-fast stains, isolate and...
40 CFR 62.12110 - Identification of plan-negative declaration.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Letter from the Division of Environmental Protection submitted March 11, 1996 certifying that there are..., subpart Cb, of this chapter. [65 FR 33467, May 24, 2000] Landfill Gas Emissions From Existing Municipal...
40 CFR 62.1960 - Identification of plan-negative declaration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the Department of Natural Resources and Environmental Control submitted March 26, 1996 certifying that... 60, subpart Cb, of this chapter. [65 FR 33466, May 24, 2000] Emissions From Existing Hospital/Medical...
49 CFR 536.5 - Trading infrastructure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the certified and reported CAFE data provided by the Environmental Protection Agency for enforcement of the CAFE program pursuant to 49 U.S.C. 32904(e). Credit values are calculated based on the CAFE...
49 CFR 536.5 - Trading infrastructure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the certified and reported CAFE data provided by the Environmental Protection Agency for enforcement of the CAFE program pursuant to 49 U.S.C. 32904(e). Credit values are calculated based on the CAFE...
Nelson, Bryant C; Sharpless, Katherine E
2003-01-29
Catechins are polyphenolic plant compounds (flavonoids) that may offer significant health benefits to humans. These benefits stem largely from their anticarcinogenic, antioxidant, and antimutagenic properties. Recent epidemiological studies suggest that the consumption of flavonoid-containing foods is associated with reduced risk of cardiovascular disease. Chocolate is a natural cocoa bean-based product that reportedly contains high levels of monomeric, oligomeric, and polymeric catechins. We have applied solid-liquid extraction and liquid chromatography coupled with atmospheric pressure chemical ionization-mass spectrometry to the identification and determination of the predominant monomeric catechins, (+)-catechin and (-)-epicatechin, in a baking chocolate Standard Reference Material (NIST Standard Reference Material 2384). (+)-Catechin and (-)-epicatechin are detected and quantified in chocolate extracts on the basis of selected-ion monitoring of their protonated [M + H](+) molecular ions. Tryptophan methyl ester is used as an internal standard. The developed method has the capacity to accurately quantify as little as 0.1 microg/mL (0.01 mg of catechin/g of chocolate) of either catechin in chocolate extracts, and the method has additionally been used to certify (+)-catechin and (-)-epicatechin levels in the baking chocolate Standard Reference Material. This is the first reported use of liquid chromatography/mass spectrometry for the quantitative determination of monomeric catechins in chocolate and the only report certifying monomeric catechin levels in a food-based Standard Reference Material.
Wang, Huan-qiang; Li, Tao; Qi, Fang; Wu, Rui; Nie, Wu; Yu, Chen
2013-10-01
To investigate the qualifications and current situations of the medical and health institutions and certified doctors for providing occupational disease diagnosis in China and to provide a reference for developing relevant policies. Work reports and questionnaires survey were used to investigate the qualifications of all medical and health institutions and certified doctors for providing occupational disease diagnosis in China and their acceptance and diagnosis of occupational disease cases from 2006 to 2010. The rate for the work reports was 100%, and the response rate for the questionnaires was 71.0%. By the end of 2010, in the 31 provincial-level regions (excluding Hong Kong, Macao, and Taiwan) in China, there had been 503 medical and health institutions which were qualified for providing occupational disease diagnosis, including 207 centers for disease control and prevention, accounting for 41.2%, 145 general hospitals, accounting for 28.8%, 69 enterprise-owned hospitals, accounting for 13.7%, and 64 institutes or centers for occupational disease prevention and control, accounting for 12.7%; 4986 certified doctors got the qualification for providing occupational disease diagnosis, with 9.4 certified doctors on average in each institution, and there was 0.65 certified doctor per 100 000 employees. In addition, 16.5% of the institutions got all the qualifications for diagnosing 9 occupational diseases, and 17.1% of the institutions got the qualification for diagnosing one occupational disease. Each certified doctor accepted diagnosis of 16.8 cases of occupational diseases on average every year. A national occupational disease diagnosis network has been established in China, but the imbalance in regional distribution and specialty programs still exists among the qualified medical and health institutions and certified doctors. It is essential to further strengthen the development of regional qualified medical and health institutions and training of qualified doctors.
NASA Astrophysics Data System (ADS)
Papapostolou, Vasileios; Zhang, Hang; Feenstra, Brandon J.; Polidori, Andrea
2017-12-01
A state-of-the-art integrated chamber system has been developed for evaluating the performance of low-cost air quality sensors. The system contains two professional grade chamber enclosures. A 1.3 m3 stainless-steel outer chamber and a 0.11 m3 Teflon-coated stainless-steel inner chamber are used to create controlled aerosol and gaseous atmospheres, respectively. Both chambers are temperature and relative humidity controlled with capability to generate a wide range of environmental conditions. The system is equipped with an integrated zero-air system, an ozone and two aerosol generation systems, a dynamic dilution calibrator, certified gas cylinders, an array of Federal Reference Method (FRM), Federal Equivalent Method (FEM), and Best Available Technology (BAT) reference instruments and an automated control and sequencing software. Our experiments have demonstrated that the chamber system is capable of generating stable and reproducible aerosol and gas concentrations at low, medium, and high levels. This paper discusses the development of the chamber system along with the methods used to quantitatively evaluate sensor performance. Considering that a significant number of academic and research institutions, government agencies, public and private institutions, and individuals are becoming interested in developing and using low-cost air quality sensors, it is important to standardize the procedures used to evaluate their performance. The information discussed herein provides a roadmap for entities who are interested in characterizing air quality sensors in a rigorous, systematic and reproducible manner.
Takatsu, Akiko
2009-06-01
There is an increasing demand to establish a metrological traceability system for in vitro diagnostics and medical devices. Pure substance-type reference materials are playing key roles in metrological traceability, because they form the basis for many traceability chains in chemistry. The National Metrology Institute of Japan (NMIJ), in the National Institute of Advanced Industrial Science and Technology (AIST), has been developing purity-certified reference materials (CRMs) in this field, such as cholesterol, creatinine, and urea. In the New Energy and Industrial Technology Development Organization (NEDO) project, entitled: "Research and Development to Promote the Creation and Utilization of an Intellectual Infrastructure: Development of Reference Materials for Laboratory Medicine", several pure substance-type CRMs were developed. For a pure protein solution CRM, amino acid analysis and nitrogen determination were chosen as the certification methods. The development and certification processes for the C-reactive protein (CRP) solution CRM were completed, with the recombinant human CRP solution as a candidate material. This CRP solution CRM is now available as NMIJ CRM. For cortisol CRM, a purified candidate material and highly pure primary reference material were prepared. Each impure compound in the materials was identified and quantified. The pure cortisol CRM will be available in 2009. These two CRMs provide a traceability link between routine clinical methods and the SI unit.
Wolf, Dominik; Bocchetta, Martina; Preboske, Gregory M; Boccardi, Marina; Grothe, Michel J
2017-08-01
A harmonized protocol (HarP) for manual hippocampal segmentation on magnetic resonance imaging (MRI) has recently been developed by an international European Alzheimer's Disease Consortium-Alzheimer's Disease Neuroimaging Initiative project. We aimed at providing consensual certified HarP hippocampal labels in Montreal Neurological Institute (MNI) standard space to serve as reference in automated image analyses. Manual HarP tracings on the high-resolution MNI152 standard space template of four expert certified HarP tracers were combined to obtain consensual bilateral hippocampus labels. Utility and validity of these reference labels is demonstrated in a simple atlas-based morphometry approach for automated calculation of HarP-compliant hippocampal volumes within SPM software. Individual tracings showed very high agreement among the four expert tracers (pairwise Jaccard indices 0.82-0.87). Automatically calculated hippocampal volumes were highly correlated (r L/R = 0.89/0.91) with gold standard volumes in the HarP benchmark data set (N = 135 MRIs), with a mean volume difference of 9% (standard deviation 7%). The consensual HarP hippocampus labels in the MNI152 template can serve as a reference standard for automated image analyses involving MNI standard space normalization. Copyright © 2017 the Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
30 CFR 18.80 - Approval of machines assembled with certified or explosion-proof components.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Modifications of Approved Machines, and Permits To Use Experimental Equipment § 18.80 Approval of machines... approval. A design of the approval plate will accompany the notification of approval. (Refer to §§ 18.10...
30 CFR 18.80 - Approval of machines assembled with certified or explosion-proof components.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Modifications of Approved Machines, and Permits To Use Experimental Equipment § 18.80 Approval of machines... approval. A design of the approval plate will accompany the notification of approval. (Refer to §§ 18.10...
30 CFR 18.80 - Approval of machines assembled with certified or explosion-proof components.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Modifications of Approved Machines, and Permits To Use Experimental Equipment § 18.80 Approval of machines... approval. A design of the approval plate will accompany the notification of approval. (Refer to §§ 18.10...
30 CFR 18.80 - Approval of machines assembled with certified or explosion-proof components.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Modifications of Approved Machines, and Permits To Use Experimental Equipment § 18.80 Approval of machines... approval. A design of the approval plate will accompany the notification of approval. (Refer to §§ 18.10...
Cloke, Jonathan; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron; Chen, Yi; Ryser, Elliot; Carter, Mark
2016-01-01
The Thermo Scientific™ SureTect™ Listeria species assay is a new real-time PCR assay for the detection of all species of Listeria in food and environmental samples. The assay was originally certified as Performance Tested Methods(SM) (PTM) 071304 in 2013. This report details the method modification study undertaken to extend the performance claims of the assay for matrixes of raw ground turkey, raw ground pork, bagged lettuce, raw pork sausages, pasteurized 2% fat milk, raw cod, pasteurized brie cheese, and ice cream. The method modification study was conducted using the AOAC Research Institute (RI) PTM program to validate the SureTect PCR assay in comparison to the reference method detailed in ISO 11290-1:1996 including amendment 1:2004. All matrixes were tested by Thermo Fisher Scientific (Basingstoke, United Kingdom). In addition, three matrixes (raw cod, bagged lettuce, and pasteurized brie cheese) were analyzed independently as part of the AOAC RI-controlled independent laboratory study by the University of Guelph, Canada. Using probability of detection statistical analysis, there was no significant difference in the performance between the SureTect assay and the International Organization for Standardization reference method for any of the matrixes analyzed in this study.
76 FR 41111 - Approval and Promulgation of Implementation Plans; South Carolina; 110(a)(1) and (2...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-13
...EPA is taking final action to approve the December 13, 2007, submission submitted by the State of South Carolina, through the South Carolina Department of Health and Environmental Control (SC DHEC) as demonstrating that the State meets the state implementation plan (SIP) requirements of sections 110(a)(1) and (2) of the Clean Air Act (CAA or the Act) for the 1997 8-hour ozone national ambient air quality standards (NAAQS). Section 110(a) of the CAA requires that each state adopt and submit a SIP for the implementation, maintenance, and enforcement of each NAAQS promulgated by the EPA, which is commonly referred to as an ``infrastructure'' SIP. South Carolina certified that the South Carolina SIP contains provisions that ensure the 1997 8-hour ozone NAAQS is implemented, enforced, and maintained in South Carolina (hereafter referred to as ``infrastructure submission''). South Carolina's infrastructure submission, provided to EPA on December 13, 2007, addressed all the required infrastructure elements for the 1997 8-hour ozone NAAQS. Additionally, EPA is correcting an inadvertent error and responding to adverse comments received on EPA's March 17, 2011, proposed approval of South Carolina's December 13, 2007, infrastructure submission.
Dennen, Kristin O.; Johnson, Craig A.; Otter, Marshall L.; Silva, Steven R.; Wandless, Gregory A.
2006-01-01
Samples of United States Geological Survey (USGS) Certified Reference Materials USGS Devonian Ohio Shale (SDO-1), and USGS Eocene Green River Shale (SGR-1), and National Research Council Canada (NRCC) Certified Marine Sediment Reference Material (PACS-2), were sent for analysis to four separate analytical laboratories as blind controls for organic rich sedimentary rock samples being analyzed from the Red Dog mine area in Alaska. The samples were analyzed for stable isotopes of carbon (delta13Cncc) and nitrogen (delta15N), percent non-carbonate carbon (Wt % Cncc) and percent nitrogen (Wt % N). SDO-1, collected from the Huron Member of the Ohio Shale, near Morehead, Kentucky, and SGR-1, collected from the Mahogany zone of the Green River Formation are petroleum source rocks used as reference materials for chemical analyses of sedimentary rocks. PACS-2 is modern marine sediment collected from the Esquimalt, British Columbia harbor. The results presented in this study are, with the exceptions noted below, the first published for these reference materials. There are published information values for the elemental concentrations of 'organic' carbon (Wt % Corg measured range is 8.98 - 10.4) and nitrogen (Wt % Ntot 0.347 with SD 0.043) only for SDO-1. The suggested values presented here should be considered 'information values' as defined by the NRCC Institute for National Measurement Reference Materials and should be useful for the analysis of 13C, 15N, C and N in organic material in sedimentary rocks.
Liu, Ying; He, Man; Chen, Beibei; Hu, Bin
2015-09-01
A new method based on dispersive liquid liquid microextraction (DLLME) combined with electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) was developed for the simultaneous speciation of inorganic arsenic (As), selenium (Se) and tellurium (Te) with sodium diethyldithiocarbamate (DDTC) as both chelating reagent and chemical modifier. As(III), Se(IV) and Te(IV) were transformed into DDTC-chelates at pH 7 and extracted into the fine droplets formed by injecting the binary solution of bromobenzene (extraction solvent) and methanol (dispersive solvent) into the sample solution. After phase separation by centrifugation, As(III), Se(IV) and Te(IV) preconcentrated in the organic phase were determined by ETV-ICP-MS. Total inorganic As, Se and Te were obtained by reducing As(V), Se(VI) and Te(VI) to As(III), Se(IV) and Te(IV) with L-cysteine, which were then subjected to the same DLLME-ETV-ICP-MS process. The concentration of As(V), Se(VI), Te(VI) were calculated by subtracting the concentration of As(III), Se(IV) and Te(IV) from the total inorganic As, Se and Te, respectively. The main factors affecting the microextraction efficiency and the vaporization behavior of target species were investigated in detail. Under the optimal conditions, the limits of detection were 2.5, 8.6 and 0.56 ng L(-1) for As(III), Se(IV) and Te(IV), respectively, with the relative standard deviations (n=7) of 8.5-9.7%. The developed method was applied to the speciation of inorganic As, Se and Te in Certified Reference Materials of GSBZ50004-88, GBW(E)080395 and GBW(E)080548 environmental waters, and the determined values are in good agreement with the certified values. The method was also successfully applied to the simultaneous speciation of inorganic As, Se and Te in different environmental water samples with the recoveries in the range of 86.3-107% for the spiked samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Cheng, Guihong; He, Man; Peng, Hanyong; Hu, Bin
2012-01-15
A fast and simple method for analysis of trace amounts of Cr(III), Cu(II), Pb(II) and Zn(II) in environmental and biological samples was developed by combining magnetic solid phase extraction (MSPE) with inductively coupled plasma-optical emission spectrometry (ICP-OES) detection. Dithizone modified silica-coated magnetic Fe(3)O(4) nanoparticles (H(2)Dz-SCMNPs) were prepared and used for MSPE of trace amounts of Cr(III), Cu(II), Pb(II) and Zn(II). The prepared magnetic nanoparticles were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray powder diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). The factors affecting the extraction of the target metal ions such as pH, sample volume, eluent, and interfering ions had been investigated and the adsorption mechanism of the target metals on the self-prepared H(2)Dz-SCMNPs was investigated by FT-IR and X-ray photo electron spectroscopy (XPS). Under the optimized conditions, the detection limits of the developed method for Cr(III), Cu(II), Pb(II) and Zn(II) were 35, 11, 62, and 8ngL(-1), respectively, with the enrichment factor of 100. The relative standard deviations (RSDs, c=10μgL(-1), n=7) were in the range of 1.7-3.1% and the linear range was 0.1-100μgL(-1). The proposed method had been validated by two certified reference materials (GSBZ50009-88 environmental water and GBW07601 human hair), and the determined values were in good agreement with the certified values. The method was also applied for the determination of trace metals in real water and human hair samples with recoveries in the range of 85-110% for the spiked samples. The developed MSPE-ICP-OES method has the advantages of simplicity, rapidity, selectivity, high extraction efficiency and is suitable for the analysis of samples with large volume and complex matrix. Copyright © 2011 Elsevier B.V. All rights reserved.
Khan, Sumaira; Kazi, Tasneem Gul; Soylak, Mustafa
2014-04-05
A rapid and innovative microextraction technique named as, ionic liquid-based ultrasound-assisted dual magnetic microextraction (IL-UA-DMME) was developed for the preconcentration and extraction of trace cadmium from environmental and biological samples, prior to analyzed by flame atomic absorption spectrometry (FAAS). The proposed method has many obvious advantages, including evading the use of organic solvents and achieved high extraction yields by the combination of dispersive liquid-liquid microextraction (DLLME) and magnetic mediated-solid phase extraction (MM-SPE). In this approach ionic liquid (IL) 1-butyl-3-methylimidazolium hexafluorophosphate [C4mim][PF6] play an important role to extract the cadmium-4-(2-thiazolylazo)-resorcinol (Cd-TAR) complex from acid digested sample solutions and ultrasonic irradiation was applied to assist emulsification. After then, dispersed small amount of Fe3O4 magnetic nanoparticles (MNPs) in sample solutions to salvaged the IL and complete phase separation was attained. Some analytical parameters that influencing the efficiency of proposed (IL-UA-DMME) method, such as pH, volume of IL, ligand concentration, ultra-sonication time, amount of Fe3O4 MNPs, sample volume and matrix effect were optimized. Limit of detection (LOD) and enrichment factor (EF) of the method under optimal experimental conditions were found to be 0.40μgL(-1) and 100, respectively. The relative standard deviation (RSD) of 50μgL(-1) Cd was 4.29%. The validity and accuracy of proposed method, was assessed to analyzed certified reference materials of fortified lake water TMDA-54.4, SPS-WW2 waste water, spinach leaves 1570a and also checked by standard addition method. The obtained values showed good agreement with the certified values and sufficiently high recovery were found in the range of 98.1-101% for Cd. The proposed method was facile, rapid and successfully applied for the determination of Cd in environmental and different biological samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Bahlai, Christine A.; Xue, Yingen; McCreary, Cara M.; Schaafsma, Arthur W.; Hallett, Rebecca H.
2010-01-01
Background Selection of pesticides with small ecological footprints is a key factor in developing sustainable agricultural systems. Policy guiding the selection of pesticides often emphasizes natural products and organic-certified pesticides to increase sustainability, because of the prevailing public opinion that natural products are uniformly safer, and thus more environmentally friendly, than synthetic chemicals. Methodology/Principal Findings We report the results of a study examining the environmental impact of several new synthetic and certified organic insecticides under consideration as reduced-risk insecticides for soybean aphid (Aphis glycines) control, using established and novel methodologies to directly quantify pesticide impact in terms of biocontrol services. We found that in addition to reduced efficacy against aphids compared to novel synthetic insecticides, organic approved insecticides had a similar or even greater negative impact on several natural enemy species in lab studies, were more detrimental to biological control organisms in field experiments, and had higher Environmental Impact Quotients at field use rates. Conclusions/Significance These data bring into caution the widely held assumption that organic pesticides are more environmentally benign than synthetic ones. All pesticides must be evaluated using an empirically-based risk assessment, because generalizations based on chemical origin do not hold true in all cases. PMID:20582315
Educator Preparedness to Teach Environmental Science in Secondary Schools
ERIC Educational Resources Information Center
Guillory, Linus Joseph, Jr.
2012-01-01
This study assesses the environmental proficiency of Texas life science educators certified from 2003 to 2011 by analyzing their TExES 138 8-12 exam results in domains V and VI. The sample consisted of all the individuals that took and passed the TExES 138 life science 8-12 exam. During this period, approximately 41% of the individuals who took…
Muller, Edson I; Souza, Juliana P; Muller, Cristiano C; Muller, Aline L H; Mello, Paola A; Bizzi, Cezar A
2016-08-15
In this work a green digestion method which only used H2O2 as an oxidant and high temperature and pressure in the single reaction chamber system (SRC-UltraWave™) was applied for subsequent elemental determination by inductively coupled plasma-based techniques. Milk powder was chosen to demonstrate the feasibility and advantages of the proposed method. Samples masses up to 500mg were efficiently digested, and the determination of Ca, Fe, K, Mg and Na was performed by inductively coupled plasma optical emission spectrometry (ICP-OES), while trace elements (B, Ba, Cd, Cu, Mn, Mo, Pb, Sr and Zn) were determined by inductively coupled plasma mass spectrometry (ICP-MS). Residual carbon (RC) lower than 918mgL(-1) of C was obtained for digests which contributed to minimizing interferences in determination by ICP-OES and ICP-MS. Accuracy was evaluated using certified reference materials NIST 1549 (non-fat milk powder certified reference material) and NIST 8435 (whole milk powder reference material). The results obtained by the proposed method were in agreement with the certified reference values (t-test, 95% confidence level). In addition, no significant difference was observed between results obtained by the proposed method and conventional wet digestion using concentrated HNO3. As digestion was performed without using any kind of acid, the characteristics of final digests were in agreement with green chemistry principles when compared to digests obtained using conventional wet digestion method with concentrated HNO3. Additionally, H2O2 digests were more suitable for subsequent analysis by ICP-based techniques due to of water being the main product of organic matrix oxidation. The proposed method was suitable for quality control of major components and trace elements present in milk powder in consonance with green sample preparation. Copyright © 2016 Elsevier B.V. All rights reserved.
STANDARD REFERENCE MATERIALS FOR THE POLYMERS INDUSTRY.
McDonough, Walter G; Orski, Sara V; Guttman, Charles M; Migler, Kalman D; Beers, Kathryn L
2016-01-01
The National Institute of Standards and Technology (NIST) provides science, industry, and government with a central source of well-characterized materials certified for chemical composition or for some chemical or physical property. These materials are designated Standard Reference Materials ® (SRMs) and are used to calibrate measuring instruments, to evaluate methods and systems, or to produce scientific data that can be referred readily to a common base. In this paper, we discuss the history of polymer based SRMs, their current status, and challenges and opportunities to develop new standards to address industrial measurement challenges.
Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki
2010-09-15
Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Preparing Nurses for a 21st Century Role in Genomics-Based Health Care.
ERIC Educational Resources Information Center
Lea, Dale Halsey; Monsen, Rita Black
2003-01-01
Suggests new practice roles for nurses resulting from genomic research and outlines the proposed position of genomics nurse care coordinator. Discusses national and international initiatives to certify nurses' genetic knowledge and skills for practice. (Contains 22 references.) (SK)
ERIC Educational Resources Information Center
New York State Education Dept., Albany. Office of the Professions.
A reference guide to laws, rules, and regulations that govern public accountancy practice in New York State is presented. In addition to identifying licensing requirements/procedures for certified public accountants, general provisions of Title VIII of the Education Law are covered, along with state management, professional misconduct, and…
Recovery. precision, limits of detection and quantitation, blank levels, calibration linearity, and agreement with certified reference materials were determined for two classes of organic components of airborne particulate matter, polycyclic aromatic hydrocarbons and hopanes usin...
Heisterkamp, M; Adams, F C
2001-07-01
The application of inductively coupled plasma--time-of-flight mass spectrometry for the speciation analysis of organolead compounds in environmental waters is described. Construction of the transfer line was achieved by means of a relatively simple and rapid coupling procedure. Derivatization of the ionic lead species was achieved by in-situ propylation with sodium tetrapropylborate; simultaneous extraction of the derivatized compounds in hexane was followed by separation and detection by capillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight mass spectrometry. Detection limits for the different organolead species ranged from 10 to 15 fg (as Pb), corresponding to procedural detection limits between 50 and 75 ng L(-1), on the basis of a 50 mL snow sample, extraction with 200 microL hexane, and subsequent injection of 1 microL of the organic extract on to the column. The accuracy of the system was confirmed by additional analysis of the water samples by capillary gas chromatography coupled with microwave-induced plasma-atomic-emission spectrometry and the analysis of a standard reference material CRM 605 (road dust) with a certified content of trimethyllead.
Abdolmohammad-Zadeh, Hossein; Tavarid, Keyvan; Talleb, Zeynab
2012-01-01
Nanostructured nickel-aluminum-zirconium ternary layered double hydroxide was successfully applied as a solid-phase extraction sorbent for the separation and pre-concentration of trace levels of iodate in food, environmental and biological samples. An indirect method was used for monitoring of the extracted iodate ions. The method is based on the reaction of the iodate with iodide in acidic solution to produce iodine, which can be spectrophotometrically monitored at 352 nm. The absorbance is directly proportional to the concentration of iodate in the sample. The effect of several parameters such as pH, sample flow rate, amount of nanosorbent, elution conditions, sample volume, and coexisting ions on the recovery was investigated. In the optimum experimental conditions, the limit of detection (3s) and enrichment factor were 0.12 μg mL−1 and 20, respectively. The calibration graph using the preconcentration system was linear in the range of 0.2–2.8 μg mL−1 with a correlation coefficient of 0.998. In order to validate the presented method, a certified reference material, NIST SRM 1549, was also analyzed. PMID:22619590
Kara, Derya; Fisher, Andrew; Hill, Steve J
2008-03-17
An on-line flow injection spectrofluorimetric method for the direct determination of aluminium in water samples is described. The method is based on the reaction of aluminium with N-o-vanillidine-2-amino-p-cresol (OVAC) in acidic medium at pH 4.0 to form a water-soluble complex. The excitation and emission wavelengths were 423.0 and 553.0nm, respectively, at which the OVAC-Al complex gave the maximum fluorescence intensity at pH 4.0 in a 50% methanol-50% water medium at 50 degrees C. An interference from fluoride ions was minimised by the addition of Be(2+). Other ions were found not to interfere at the concentrations likely to be found in natural waters. The proposed methods were validated in terms of linearity, repeatability, detection limit, accuracy and selectivity. Under these conditions, the calibration was linear up to 1000microgL(-1) (r=0.999). The limit of detection (3sigma) for the determination of Al(III) was 0.057microgL(-1) and the precision for multiple determinations of 3ngmL(-1) Al(III) prepared in ultra-pure water was found to be 0.62% (n=10). The Schiff base ligand could be used to determine ultra-trace aluminium from natural waters. Analysis of environmental certified reference materials showed good agreement with the certified values. The procedure was found to be equally applicable to both freshwater and saline solutions, including seawater.
Certified randomness in quantum physics.
Acín, Antonio; Masanes, Lluis
2016-12-07
The concept of randomness plays an important part in many disciplines. On the one hand, the question of whether random processes exist is fundamental for our understanding of nature. On the other, randomness is a resource for cryptography, algorithms and simulations. Standard methods for generating randomness rely on assumptions about the devices that are often not valid in practice. However, quantum technologies enable new methods for generating certified randomness, based on the violation of Bell inequalities. These methods are referred to as device-independent because they do not rely on any modelling of the devices. Here we review efforts to design device-independent randomness generators and the associated challenges.
Boulyga, Sergei F; Heilmann, Jens; Prohaska, Thomas; Heumann, Klaus G
2007-10-01
A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for (35)Cl+ to more than 6 x 10(5) cps for (238)U+ for 1 microg of trace element per gram of coal sample. Detection limits vary from 450 ng g(-1) for chlorine and 18 ng g(-1) for sulfur to 9.5 pg g(-1) for mercury and 0.3 pg g(-1) for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis.
NASA Astrophysics Data System (ADS)
Ding, Liang; Wang, Shui; Cai, Bingjie; Zhang, Mancheng; Qu, Changsheng
2018-02-01
In this study, portable X-ray fluorescence spectrometry (pXRF) was used to measure the heavy metal contents of As, Cu, Cr, Ni, Pb and Zn in the soils of heavy metal-contaminated sites. The precision, accuracy and system errors of pXRF were evaluated and compared with traditional laboratory methods to examine the suitability of in situ pXRF. The results show that the pXRF analysis achieved satisfactory accuracy and precision in measuring As, Cr, Cu, Ni, Pb, and Zn in soils, and meets the requirements of the relevant detection technology specifications. For the certified reference soil samples, the pXRF results of As, Cr, Cu, Ni, Pb, and Zn show good linear relationships and coefficients of determination with the values measured using the reference analysis methods; with the exception of Ni, all the measured values were within the 95% confidence level. In the soil samples, the coefficients of determination between Cu, Zn, Pb, and Ni concentrations measured laboratory pXRF and the values measured with laboratory analysis all reach 0.9, showing a good linear relationship; however, there were large deviations between methods for Cr and As. This study provides reference data and scientific support for rapid detection of heavy metals in soils using pXRF in site investigation, which can better guide the practical application of pXRF.
Numata, Masahiko; Yarita, Takashi; Aoyagi, Yoshie; Tsuda, Yoko; Yamazaki, Misako; Takatsu, Akiko; Ishikawa, Keiichiro; Chiba, Koichi; Okamaoto, Kensaku
2007-04-01
Two marine sediment certified reference materials, NMIJ CRM 7304-a and 7305-a, have been issued by the National Metrology Institute of Japan in the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) for the determination of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs). The raw materials of the CRMs were collected from a bay near industrial activity in Japan. Characterization of these CRMs was conducted by NMIJ, where the sediments were analyzed using multiple analytical methods such as pressurized liquid extraction (PLE), microwave-assisted extraction (MAE), saponification, Soxhlet extraction, supercritical fluid extraction (SFE), and ultrasonic extraction; the target compounds were determined by one of the primary methods of measurements, isotope dilution-mass spectrometry (ID-MS). Certified values have been provided for 14 PCB congeners (PCB numbers 3, 15, 28, 31, 70, 101, 105, 138, 153, 170, 180, 194, 206, 209) and 4 OCPs (gamma-HCH, 4,4'-DDT, 4,4'-DDE, 4,4'-DDD) in both CRMs. NMIJ CRM 7304-a has concentrations of the contaminants that are a factor of 2-15 greater than in CRM 7305-a. Both CRMs have information values for PCB homolog concentrations determined by collaborative analysis using a Japanese official method for determination of PCBs. The total PCB concentrations in the CRMs are approximately 920 and 86 microg kg(-1) dry mass respectively.
NASA Astrophysics Data System (ADS)
Lehtimäki, Esa; Väisänen, Ari
2017-01-01
The digestion methods for the determination of As, Cd, Cr, Pb, Sb, Sn and Zn concentrations in plastic samples using microwave-assisted digestion (MW-AD) and small-size autoclave digestion was developed. The certified polyethylene, polypropylene, polyvinyl chloride and acrylonitrile butadiene styrene certified reference materials were used in order to find digestion method working properly for several sample matrices. Efficiency of the digestion methods was evaluated by analyzing the residual carbon in digests by TOC analyzer. MW-AD using a mixture of 7 mL of HNO3 and 3 mL of H2O2 as a digestion solution resulted in excellent recoveries for As, Cd, Pb, Sb and Zn, and were in the range of 92-107% for all the analytes except Pb in polyethylene material. Autoclave digestion using 5 mL of concentrated HNO3 as a digestion solution resulted in similar recoveries with the exception of a higher As recovery (98%). Tin recovery resulted in low level after both MW-AD and autoclave digestion. Autoclave digestion was further developed resulting in a partially open two-step digestion process especially for the determination of Sn and Cr. The method resulted in higher recoveries of Sn and Cr (87 and 76%) but with the lower concentration of easily volatile As, Cd and Sb.
NASA Astrophysics Data System (ADS)
Krawczyk-Coda, Magdalena
2017-03-01
In this research, a simple, accurate, and inexpensive preconcentration procedure was developed for the determination of bismuth in water samples, using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS). During the preconcentration step, halloysite nanotubes (HNTs) were used as a solid sorbent in ultrasound-assisted dispersive micro solid-phase extraction (USA DMSPE). The influence of the pH of the sample solution, amount of HNTs, and extraction time, as well as of the main parameters of HR CS GFAAS, on absorbance was investigated. The limit of detection was 0.005 μg L- 1. The preconcentration factor achieved for bismuth was 32. The relative standard deviation (RSD) was 4%. The accuracy of this method was validated by analyses of NIST SRM 1643e (Trace elements in water) and TMDA-54.5 (A high level fortified sample for trace elements) certified reference materials. The measured bismuth contents in these certified reference materials were in satisfactory agreement with the certified values according to the t-test for a 95% confidence level. The proposed method has been successfully applied to the determination of bismuth in five different real water samples (seawater, lake water, river water, stream water and rain water).
The Impact of Working in a Green Certified Building on Cognitive Function and Health.
MacNaughton, Piers; Satish, Usha; Laurent, Jose Guillermo Cedeno; Flanigan, Skye; Vallarino, Jose; Coull, Brent; Spengler, John D; Allen, Joseph G
2017-03-01
Thirty years of public health research have demonstrated that improved indoor environmental quality is associated with better health outcomes. Recent research has demonstrated an impact of the indoor environment on cognitive function. We recruited 109 participants from 10 high-performing buildings (i.e. buildings surpassing the ASHRAE Standard 62.1-2010 ventilation requirement and with low total volatile organic compound concentrations) in five U.S. cities. In each city, buildings were matched by week of assessment, tenant, type of worker and work functions. A key distinction between the matched buildings was whether they had achieved green certification. Workers were administered a cognitive function test of higher order decision-making performance twice during the same week while indoor environmental quality parameters were monitored. Workers in green certified buildings scored 26.4% (95% CI: [12.8%, 39.7%]) higher on cognitive function tests, controlling for annual earnings, job category and level of schooling, and had 30% fewer sick building symptoms than those in non-certified buildings. These outcomes may be partially explained by IEQ factors, including thermal conditions and lighting, but the findings suggest that the benefits of green certification standards go beyond measureable IEQ factors. We describe a holistic "buildingomics" approach for examining the complexity of factors in a building that influence human health.
The Impact of Working in a Green Certified Building on Cognitive Function and Health
MacNaughton, Piers; Satish, Usha; Laurent, Jose Guillermo Cedeno; Flanigan, Skye; Vallarino, Jose; Coull, Brent; Spengler, John D.; Allen, Joseph G.
2017-01-01
Thirty years of public health research have demonstrated that improved indoor environmental quality is associated with better health outcomes. Recent research has demonstrated an impact of the indoor environment on cognitive function. We recruited 109 participants from 10 high-performing buildings (i.e. buildings surpassing the ASHRAE Standard 62.1-2010 ventilation requirement and with low total volatile organic compound concentrations) in five U.S. cities. In each city, buildings were matched by week of assessment, tenant, type of worker and work functions. A key distinction between the matched buildings was whether they had achieved green certification. Workers were administered a cognitive function test of higher order decision-making performance twice during the same week while indoor environmental quality parameters were monitored. Workers in green certified buildings scored 26.4% (95% CI: [12.8%, 39.7%]) higher on cognitive function tests, controlling for annual earnings, job category and level of schooling, and had 30% fewer sick building symptoms than those in non-certified buildings. These outcomes may be partially explained by IEQ factors, including thermal conditions and lighting, but the findings suggest that the benefits of green certification standards go beyond measureable IEQ factors. We describe a holistic “buildingomics” approach for examining the complexity of factors in a building that influence human health. PMID:28785124
National athletic trainers' association position statement: skin diseases.
Zinder, Steven M; Basler, Rodney S W; Foley, Jack; Scarlata, Chris; Vasily, David B
2010-01-01
To present recommendations for the prevention, education, and management of skin infections in athletes. Trauma, environmental factors, and infectious agents act together to continually attack the integrity of the skin. Close quarters combined with general poor hygiene practices make athletes particularly vulnerable to contracting skin diseases. An understanding of basic prophylactic measures, clinical features, and swift management of common skin diseases is essential for certified athletic trainers to aid in preventing the spread of infectious agents. These guidelines are intended to provide relevant information on skin infections and to give specific recommendations for certified athletic trainers and others participating in athletic health care.
Liu, Ning; Tang, Shui-Yan; Zhan, Xueyong; Lo, Carlos Wing-Hung
2018-08-01
This study combines insights from the policy uncertainty literature and neo-institutional theory to examine corporate performance in implementing a government-sponsored voluntary environmental program (VEP) during 2004-2012 in Guangzhou, China. In this regulatory context, characterized by rapid policy changes, corporate performance in VEPs is affected by government surveillance, policy uncertainty, and peer pressures. Specifically, if VEP participants have experienced more government surveillance, they tend to perform better in program implementation. Such positive influence of government surveillance is particularly evident among those joining under high and low, rather than moderate uncertainty. Participants also perform better if they belong to an industry with more certified VEP firms, but worse if they are located in a regulatory jurisdiction with more certified VEP firms. At a moderate level of policy uncertainty, within-industry imitation is most likely to occur but within-jurisdiction imitation is least likely to occur. Copyright © 2018 Elsevier Ltd. All rights reserved.
Zemberyová, Mária; Barteková, Jana; Hagarová, Ingrid
2006-12-15
A modified three-step sequential extraction procedure for the fractionation of heavy metals, proposed by the Commission of the European Communities Bureau of Reference (BCR) has been applied to the Slovak reference materials of soils (soil orthic luvisols, soil rendzina and soil eutric cambisol), which represent pedologically different types of soils in Slovakia. Analyses were carried out by flame or electrothermal atomic absorption spectrometry (FAAS or ETAAS). The fractions extracted were: exchangeable (extraction step 1), reducible-iron/manganese oxides (extraction step 2), oxidizable-organic matter and sulfides (extraction step 3). The sum of the element contents in the three fractions plus aqua-regia extractable content of the residue was compared to the aqua-regia extractable content of the elements in the origin soils. The accuracy obtained by comparing the determined contents of the elements with certified values, using BCR CRM 701, certified for the extractable contents (mass fractions) of Cd, Cr, Cu, Ni, Pb and Zn in sediment following a modified BCR-three step sequential extraction procedure, was found to be satisfactory.
SUstaiNability: a science communication website on environmental research
NASA Astrophysics Data System (ADS)
Gravina, Teresita; Rutigliano, Flora Angela
2015-04-01
Environmental news mainly reach not specialist people by mass media, which generally focuses on fascinating or catastrophic events without reporting scientific data. Otherwise, scientific data on environment are published in peer-reviewed journals with specific language, so they could be not understandable to common people. In the last decade, Internet spread made easier to divulge environmental information. This allows everyone (scientist or not) to publish information without revision. In fact, World Wide Web includes many scientific sites with different levels of confidence. Within Italian scientific websites, there are those of University and Research Centre, but they mainly contain didactic and bureaucratic information, generally lacking in research news, or reporting them in peer-reviewed format. University and Research Centre should have an important role to divulge certified information, but news should be adapted to a general audience without scientific skills, in order to help population to gain knowledge on environmental issues and to develop responsible behavior. Therefore, an attractive website (www.sunability.unina2.it) has been created in order to divulge research products of Environmental, Biological and Pharmaceutical Sciences and Technologies Department (DiSTABiF) of Second University of Naples-SUN (Campania, Southern Italy). This website contains divulgation articles derived from peer-reviewed publications of DiSTABiF researchers and concerning studies on environmental, nutrition, and health issues, closely related topics. Environmental studies mainly referred to Caserta district (Southern Italy), where DiSTABiF is located. Divulgation articles have been shared by main social networks (Facebook: sunability, Twitter: @SUNability) and accesses have been monitored for 28 days in order to obtain demographic and geographic information about users and visualization number of both DiSTABiF website and social network pages. Demographic and geographic analysis showed that social network users mainly were from Campania and they were 18-44 years old. In the observation period, almost 62600 users were reached thanks to social networks; while the number of website visualization was lower (3306). However, social buttons revealed that people appreciated website articles more than Facebook posts and tweets. Data suggest that social networks could be useful to reach many web users interested in environmental topics, but science communication needs more space than that available in social networks. Therefore, an institutional website is more suitable and qualified to refer scientific topics to common audience, including all essential information.
20 CFR 656.24 - Labor certification determinations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... officers in the ETA application processing centers have the authority to certify or deny labor... an ETA application processing center may refer the matter to the Office of Foreign Labor... applications or specific applications be handled in the ETA national office, the Directors of the ETA...
Ma, Shishuai; He, Man; Chen, Beibei; Deng, Wenchao; Zheng, Qi; Hu, Bin
2016-01-01
In this work, γ-mercaptopropyltrimethoxysilane (γ-MPTS) modified Fe3O4@SiO2 magnetic nanoparticles (MNPs) was successfully prepared, and characterized by Fourier transform infrared spectrometer (FT-IR), Transmission electron microscope (TEM) and Vibrating sample magnetometer (VSM). The sorption performance of the prepared Fe3O4@SiO2@γ-MPTS MNPs towards methylmercury (CH3Hg(+)) and inorganic mercury (Hg(2+)) was investigated. It was found that CH3Hg(+) and Hg(2+) could be simultaneously retained on the prepared Fe3O4@SiO2@γ-MPTS MNPs, and the quantitative elution of CH3Hg(+) and total mercury (THg) was achieved by using 1.5 mol L(-1) HCl containing 0.01% and 3% thiourea (m/v), respectively. And the levels of Hg(2+) were obtained by subtracting CH3Hg(+) from THg. Based on the above facts, a method of magnetic solid phase extraction (MSPE) combined with inductively coupled plasma mass spectrometry (ICP-MS) was developed for the speciation of CH3Hg(+) and Hg(2+). Various experimental parameters affecting MSPE of CH3Hg(+) and Hg(2+) such as pH, eluent, sample volume, and co-existing ions have been studied. Under the optimized conditions, the limits of detection (LODs) for CH3Hg(+) and THg were 1.6 and 1.9 ng L(-1), respectively. The accuracy of the proposed method was validated by analysis of a Certified Reference Material NRCC DORM-2 dogfish muscle, and the determined values are in good agreement with the certified values. The proposed method has also been successfully applied for the speciation of CH3Hg(+) and Hg(2+) in environmental water and human hair samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Jiang, Hong-mei; Yang, Ting; Wang, Yan-hong; Lian, Hong-zhen; Hu, Xin
2013-11-15
A new approach of magnetic solid phase extraction (MSPE) coupled with graphite furnace atomic absorption spectrometry (GFAAS) has been developed for the speciation of Cr(III) and Cr(VI) using zincon-immobilized silica-coated magnetic Fe3O4 nanoparticles (Zincon-Si-MNPs) as the MSPE absorbent. Cr(III) was quantitatively reserved on the absorbent at pH 9.1 while total Cr was reserved at pH 6.5. The absorbed Cr species were eluted by using 2 mol/L HCl and detected by GFAAS. The concentration of Cr(VI) could be calculated by subtracting Cr(III) from total Cr. All the parameters affecting the separation and extraction efficiency of Cr species such as pH, extraction time, concentration and volume of eluent, sample volume and influence of co-existing ions were systematically examined and the optimized conditions were established accordingly. The detection limit (LOD) of the method was 0.016 and 0.011 ng mL(-1) for Cr(III) and Cr(VI), respectively, with the enrichment factor of 100 and 150. The precisions of this method (Relative standard deviation, RSD, n=7) for Cr(III) and Cr(VI) at 0.1 ng mL(-1) were 6.0% and 6.2%, respectively. In order to validate the proposed method, a certified reference material of environmental water was analyzed, and the result of Cr speciation was in good agreement with the certified value. This MSPE-GFAAS method has been successfully applied for the speciation of Cr(III) and Cr(VI) in lake and tap waters with the recoveries of 88-109% for the spiked samples. Moreover, the MSPE separation mechanism of Cr(III) and Cr(VI) based on their adsorption-desorption on Zincon-Si-MNPs has been explained through various spectroscopic characterization. © 2013 Elsevier B.V. All rights reserved.
Najafi, Nahid Mashkouri; Tavakoli, Hamed; Alizadeh, Reza; Seidi, Shahram
2010-06-18
A simple and powerful method has been developed for the rapid and selective determination of Te(IV) and Te(VI), employing dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry using palladium as permanent modifier. Under acidic conditions pH 1, only Te(IV) can form a complex with ammonium pyrrolidine dithiocarbamate (APDC) and therefore be extracted into fine droplets of carbon tetrachloride (extraction solvent) which are dispersed with ethanol into the water sample solution. After centrifugation, Te(IV) was determined in the sedimented organic phase while Te(VI) remained in the aqueous phase. Total inorganic tellurium was determined after the reduction of the Te(VI) to Te(IV). Te(VI) was calculated as the difference between the measured total inorganic tellurium and Te(IV) content. The effective parameters for improving the efficiency of microextraction process were investigated by using experimental and central composite designs. Under optimal conditions the enrichment factor was 125 and the calibration graph was linear in the range of 0.015-1 ng mL(-1) with detection limit and characteristic mass of 0.004 ng mL(-1) and 0.033 pg, respectively. The relative standard deviation for 0.5 ng mL(-1) of tellurium measurement was 3.6% (n=6) at ash and atomization temperature, 900 and 2600 degrees C, respectively. The recoveries of spiked Te(IV) and Te(VI) to the environmental water samples were 89.6-101.3% and 96.6-99.1%, respectively. The accuracy is also evaluated by applying the proposed method to certified reference material (NIST SRM 1643e), for which the result was in a good agreement with the certified values reported for this CRM (95% confidence level). 2010 Elsevier B.V. All rights reserved.
Samczyński, Zbigniew; Dybczyński, Rajmund S.; Polkowska-Motrenko, Halina; Chajduk, Ewelina; Pyszynska, Marta; Danko, Bożena; Czerska, Elżbieta; Kulisa, Krzysztof; Doner, Katarzyna; Kalbarczyk, Paweł
2012-01-01
The preparation, certification, and characterization of two new biological certified reference materials for inorganic trace analysis have been presented. They are based on two different varieties of tobacco leaves, namely, Oriental Basma Tobacco Leaves (INCT-OBTL-5), grown in Greece, and Polish Virginia Tobacco Leaves (INCT-PVTL-6), grown in Poland. Certification of the materials was based on the statistical evaluation of results obtained in a worldwide interlaboratory comparison, in which 87 laboratories from 18 countries participated, providing 2568 laboratory averages on nearly 80 elements. It was possible to establish the certified values of concentration for many elements in the new materials, that is, 37 in INCT-OBTL-5 and 36 in INCT-PVTL-6, including several toxic ones like As, Cd, Hg, Pb, and so forth. The share and the role of instrumental analytical techniques used in the process of certification of the new CRMs are discussed. PMID:22536124
Uranium Isotopic Ratio Measurements of U3O8 Reference Materials by Atom Probe Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fahey, Albert J.; Perea, Daniel E.; Bartrand, Jonah AG
2016-01-01
We report results of measurements of isotopic ratios obtained with atom probe tomography on U3O8 reference materials certified for their isotopic abundances of uranium. The results show good agreement with the certified values. High backgrounds due to tails from adjacent peaks complicate the measurement of the integrated peak areas as well as the fact that only oxides of uranium appear in the spectrum, the most intense of which is doubly charged. In addition, lack of knowledge of other instrumental parameters, such as the dead time, may bias the results. Isotopic ratio measurements can be performed at the nanometer-scale with themore » expectation of sensible results. The abundance sensitivity and mass resolving power of the mass spectrometer are not sufficient to compete with magnetic-sector instruments but are not far from measurements made by ToF-SIMS of other isotopic systems. The agreement of the major isotope ratios is more than sufficient to distinguish most anthropogenic compositions from natural.« less
Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka
2015-01-01
To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.
Turk, Gregory C; Sharpless, Katherine E; Cleveland, Danielle; Jongsma, Candice; Mackey, Elizabeth A; Marlow, Anthony F; Oflaz, Rabia; Paul, Rick L; Sieber, John R; Thompson, Robert Q; Wood, Laura J; Yu, Lee L; Zeisler, Rolf; Wise, Stephen A; Yen, James H; Christopher, Steven J; Day, Russell D; Long, Stephen E; Greene, Ella; Harnly, James; Ho, I-Pin; Betz, Joseph M
2013-01-01
Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.
Rastogi, L.; Dash, K.; Arunachalam, J.
2013-01-01
The quantitative analysis of glutathione (GSH) is important in different fields like medicine, biology, and biotechnology. Accurate quantitative measurements of this analyte have been hampered by the lack of well characterized reference standards. The proposed procedure is intended to provide an accurate and definitive method for the quantitation of GSH for reference measurements. Measurement of the stoichiometrically existing sulfur content in purified GSH offers an approach for its quantitation and calibration through an appropriate characterized reference material (CRM) for sulfur would provide a methodology for the certification of GSH quantity, that is traceable to SI (International system of units). The inductively coupled plasma optical emission spectrometry (ICP-OES) approach negates the need for any sample digestion. The sulfur content of the purified GSH is quantitatively converted into sulfate ions by microwave-assisted UV digestion in the presence of hydrogen peroxide prior to ion chromatography (IC) measurements. The measurement of sulfur by ICP-OES and IC (as sulfate) using the “high performance” methodology could be useful for characterizing primary calibration standards and certified reference materials with low uncertainties. The relative expanded uncertainties (% U) expressed at 95% confidence interval for ICP-OES analyses varied from 0.1% to 0.3%, while in the case of IC, they were between 0.2% and 1.2%. The described methods are more suitable for characterizing primary calibration standards and certifying reference materials of GSH, than for routine measurements. PMID:29403814
Development of saw palmetto (Serenoa repens) fruit and extract standard reference materials.
Schantz, Michele M; Bedner, Mary; Long, Stephen E; Molloy, John L; Murphy, Karen E; Porter, Barbara J; Putzbach, Karsten; Rimmer, Catherine A; Sander, Lane C; Sharpless, Katherine E; Thomas, Jeanice B; Wise, Stephen A; Wood, Laura J; Yen, James H; Yarita, Takashi; NguyenPho, Agnes; Sorenson, Wendy R; Betz, Joseph M
2008-10-01
As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM...) For fuel tanks that are certified based on permeability treatments for plastic fuel tanks, you do not...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM...) For fuel tanks that are certified based on permeability treatments for plastic fuel tanks, you do not...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM...) For fuel tanks that are certified based on permeability treatments for plastic fuel tanks, you do not...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM...) For fuel tanks that are certified based on permeability treatments for plastic fuel tanks, you do not...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM...) For fuel tanks that are certified based on permeability treatments for plastic fuel tanks, you do not...
NASA Astrophysics Data System (ADS)
Nour, S.; Karam, L. R.; Inn, K. G. W.
2012-01-01
In 2005, the CCRI decided that a comparison undertaken from 2002 to 2008 by the NIST (under the auspices of the Inter-America Metrology System [SIM]) in the development of a new biota (Ocean Shellfish) standard reference material (SRM) was sufficiently well constructed that it could be converted into a supplementary comparison under CCRI(II), with comparison identifier CCRI(II)-S3. This would enable the comparison to be used to support calibration and measurement capability (CMC) claims for radionuclide measurements in reference materials (specifically, animal-based organic materials). Previous comparisons of radionuclides have been of single or multiple nuclides in non-complex matrices and results of such could not be extended to support capabilities to measure the same nuclides in reference materials. The results of this comparison have been used to determine the certified reference value of the SRM. The key comparison working group (KCWG) of the CCRI(II) has approved this approach as a mechanism to link all the results to certified 'reference values' in lieu of the key comparison reference value (KCRV) of these specified radionuclides in this type of matrix (shellfish) so as to support CMCs of similar materials submitted by the present participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Boshkova, T; Mitev, K
2016-03-01
In this work we present test procedures, approval criteria and results from two metrological inspections of a certified large volume (152)Eu source (drum about 200L) intended for calibration of HPGe gamma assay systems used for activity measurement of radioactive waste drums. The aim of the inspections was to prove the stability of the calibration source during its working life. The large volume source was designed and produced in 2007. It consists of 448 identical sealed radioactive sources (modules) apportioned in 32 transparent plastic tubes which were placed in a wooden matrix which filled the drum. During the inspections the modules were subjected to tests for verification of their certified characteristics. The results show a perfect compliance with the NIST basic guidelines for the properties of a radioactive certified reference material (CRM) and demonstrate the stability of the large volume CRM-drum after 7 years of operation. Copyright © 2015 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Arizona Univ., Tucson. Cooperative Extension Service.
This manual supplies information helpful to individuals wishing to become certified in public health pest control. It is designed as a technical reference for vector control workers and as preparatory material for structural applicators of restricted use pesticides to meet the General Standards of Competency required of commercial applicators. The…
43 CFR 32.4 - Program operation requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for the management of each Corps camp and project, final selection of enrollees, determination of... refer all candidates who self-certify that they meet eligibility requirements to Grantees for selection of those to be enrolled. Self-certification by applicants ages 16 through 18 who have left school...
Metrological traceability of holmium oxide solution
NASA Astrophysics Data System (ADS)
Gonçalves, D. E. F.; Gomes, J. F. S.; Alvarenga, A. P. D.; Borges, P. P.; Araujo, T. O.
2018-03-01
Holmium oxide solution was prepared as a candidate of certified reference material for spectrophotometer wavelength scale calibration. Here is presented the necessary steps for evaluation of the uncertainty and the establishment of metrological traceability for the production of this material. Preliminary results from the first produced batch are shown.
40 CFR 1054.701 - General provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1054.701 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... include engines or equipment certified for California if California has more stringent emission standards for these products or if your products generate or use emission credits under the California program...
40 CFR 1054.701 - General provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 1054.701 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... include engines or equipment certified for California if California has more stringent emission standards for these products or if your products generate or use emission credits under the California program...
40 CFR 1054.701 - General provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 1054.701 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... include engines or equipment certified for California if California has more stringent emission standards for these products or if your products generate or use emission credits under the California program...
40 CFR 1054.701 - General provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 1054.701 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... include engines or equipment certified for California if California has more stringent emission standards for these products or if your products generate or use emission credits under the California program...
40 CFR 1054.701 - General provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 1054.701 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... include engines or equipment certified for California if California has more stringent emission standards for these products or if your products generate or use emission credits under the California program...
40 CFR 62.7450 - Identification of plan-negative declaration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... of New Hampshire Department of Environmental Services submitted letters certifying no Hospital... PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF STATE PLANS FOR DESIGNATED FACILITIES AND POLLUTANTS New Hampshire Air Emissions from Existing Hospital/medical/infectious Waste Incinerators § 62.7450...
40 CFR 62.7851 - Identification of sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Air Pollution Control Division dated November 23, 2004, certifying that there are no existing sulfuric... Section 62.7851 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF STATE PLANS FOR DESIGNATED FACILITIES AND POLLUTANTS New Mexico...
40 CFR 62.7851 - Identification of sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Air Pollution Control Division dated November 23, 2004, certifying that there are no existing sulfuric... Section 62.7851 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF STATE PLANS FOR DESIGNATED FACILITIES AND POLLUTANTS New Mexico...
40 CFR 62.7851 - Identification of sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Air Pollution Control Division dated November 23, 2004, certifying that there are no existing sulfuric... Section 62.7851 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF STATE PLANS FOR DESIGNATED FACILITIES AND POLLUTANTS New Mexico...
13 CFR 400.205 - Application process.
Code of Federal Regulations, 2010 CFR
2010-01-01
... appropriate environmental site assessments, and current personal and corporate financial statements of any... statements of guarantors shall be prepared by independent Certified Public Accountants; (8) Consolidated financial statements of the Borrower for the previous three years that have been audited by an independent...
78 FR 44199 - Semiannual Regulatory Agenda, Spring 2013
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-23
..., interstate movement, and environmental release of certain genetically engineered organisms. This rule will... genetically engineered plants and certain other genetically engineered organisms. Timetable: Action Date FR... Citrus Canker; 0579-AC05 Compensation for Certified Citrus Nursery Stock. 17 Introduction of Organisms...
77 FR 5703 - Approval and Promulgation of Implementation Plans; North Carolina; 110(a)(1) and (2...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-06
... and Promulgation of Implementation Plans; North Carolina; 110(a)(1) and (2) Infrastructure... Carolina, through the Department of Environment and Natural Resources (NC DENR), Division of Air Quality... is commonly referred to as an ``infrastructure'' SIP. North Carolina certified that the North...
20 CFR 416.938 - What we mean by approved institutions or facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... INCOME FOR THE AGED, BLIND, AND DISABLED Determining Disability and Blindness Drug Addiction and... drug addiction or alcoholism in conformity with applicable Federal or State laws and regulations; (b... refer persons for treatment of drug addiction or alcoholism; (c) State licensed or certified care...
20 CFR 416.938 - What we mean by approved institutions or facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... INCOME FOR THE AGED, BLIND, AND DISABLED Determining Disability and Blindness Drug Addiction and... drug addiction or alcoholism in conformity with applicable Federal or State laws and regulations; (b... refer persons for treatment of drug addiction or alcoholism; (c) State licensed or certified care...
20 CFR 416.938 - What we mean by approved institutions or facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... INCOME FOR THE AGED, BLIND, AND DISABLED Determining Disability and Blindness Drug Addiction and... drug addiction or alcoholism in conformity with applicable Federal or State laws and regulations; (b... refer persons for treatment of drug addiction or alcoholism; (c) State licensed or certified care...
20 CFR 416.938 - What we mean by approved institutions or facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... INCOME FOR THE AGED, BLIND, AND DISABLED Determining Disability and Blindness Drug Addiction and... drug addiction or alcoholism in conformity with applicable Federal or State laws and regulations; (b... refer persons for treatment of drug addiction or alcoholism; (c) State licensed or certified care...
75 FR 47504 - Voluntary Education Programs
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-06
... in a material way the economy; a section of the economy; productivity; competition; jobs; the... Reform Act'' It has been certified that 32 CFR part 68 does not contain a Federal mandate that may result... successful job performance and new learning. Also referred to as functional or basic skills. Active Guard and...
34 CFR 668.23 - Compliance audits and audited financial statements.
Code of Federal Regulations, 2011 CFR
2011-07-01
...” refers to an independent certified public accountant or a government auditor. To conduct an audit under... to records, audit work papers, or other documents necessary to review that audit, including the right to obtain copies of those records, work papers, or documents. (2) An institution must give the...
34 CFR 668.23 - Compliance audits and audited financial statements.
Code of Federal Regulations, 2013 CFR
2013-07-01
...” refers to an independent certified public accountant or a government auditor. To conduct an audit under... to records, audit work papers, or other documents necessary to review that audit, including the right to obtain copies of those records, work papers, or documents. (2) An institution must give the...
34 CFR 668.23 - Compliance audits and audited financial statements.
Code of Federal Regulations, 2014 CFR
2014-07-01
...” refers to an independent certified public accountant or a government auditor. To conduct an audit under... to records, audit work papers, or other documents necessary to review that audit, including the right to obtain copies of those records, work papers, or documents. (2) An institution must give the...
34 CFR 668.23 - Compliance audits and audited financial statements.
Code of Federal Regulations, 2012 CFR
2012-07-01
...” refers to an independent certified public accountant or a government auditor. To conduct an audit under... to records, audit work papers, or other documents necessary to review that audit, including the right to obtain copies of those records, work papers, or documents. (2) An institution must give the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-21
... recovery and/or recovery and recycling equipment (hereafter referred to as ``refrigerant handling equipment... systems for the purposes of collecting, validating, and verifying information, processing and maintaining... approved refrigerant reclaimed by owners of refrigerant recycling equipment certified under 40 CFR 82.36(a...
33 CFR 154.2010 - Qualifications for acceptance as a certifying entity.
Code of Federal Regulations, 2014 CFR
2014-07-01
... qualifications: (a) The ability to review and evaluate design drawings and failure analyses for compliance to... incorporated by reference; (c) The ability to monitor and evaluate test procedures and results for compliance with the operational requirements of this subpart; (d) The ability to perform inspections and observe...
National Athletic Trainers' Association Position Statement: Skin Diseases
Zinder, Steven M.; Basler, Rodney S. W.; Foley, Jack; Scarlata, Chris; Vasily, David B.
2010-01-01
Abstract Objective: To present recommendations for the prevention, education, and management of skin infections in athletes. Background: Trauma, environmental factors, and infectious agents act together to continually attack the integrity of the skin. Close quarters combined with general poor hygiene practices make athletes particularly vulnerable to contracting skin diseases. An understanding of basic prophylactic measures, clinical features, and swift management of common skin diseases is essential for certified athletic trainers to aid in preventing the spread of infectious agents. Recommendations: These guidelines are intended to provide relevant information on skin infections and to give specific recommendations for certified athletic trainers and others participating in athletic health care. PMID:20617918
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-13
...Pursuant to the provisions of the Privacy Act of 1974 (5 U.S.C. 552a), the Environmental Protection Agency's (EPA) Office of Pesticide Programs, Field and External Affairs Division, is giving notice that it proposes to amend an existing system of records that contains personally identifiable information (PII) which is collected in the process of certifying individuals to apply restricted use pesticides (RUPs) as private or commercial applicators. This amendment gives notice that the Agency plans to make the name of the applicator and information pertaining to the certification granted by EPA publicly available on an EPA Web site.
Database of natural matrix reference materials (NMRM) for organic constituents.
Iyengar, G V; Bleise, A R
2001-06-01
The International Atomic Energy Agency maintains a database of internationally available certified reference materials (CRM) of natural matrices. This database is periodically updated, and presently documents nearly 25,000 measurands in 1,700 materials. The organic constituents are classified in five major groups of analytes aliphatic and aromatic hydrocarbons (A), chlorinated hydrocarbons (B), pesticides (C), organometallic compounds (D) and other organic constituents (nutrients, etc.) (E). The matrices include natural materials such as body fluids, food products, soils, and sediments, terrestrial (e.g. plants), and anthropogenic products (e.g. dust, fly ash). These five organic groups of analytes encompass more than 2000 measurands for 420 different analytes in 230 materials. Of these measurands, 1,682 (68%) are certified, and 768 (32%) are provided as informational values. Within each major group of analytes, measurands reported as informational values accounted for: A (35%); B (35%); C (26%); D (10%), and E (22%). The high proportion of informational values (i.e. non-certified values) for A, B, and C, compares well with a similar but undesirable situation faced in the nineteen-seventies in the inorganic area when simultaneous multielement techniques became available. In the case of D and E, it appears that mostly targeted analytes are measured, leading to a cohesive certification profile. Although the IAEA database is not equally comprehensive for all groups of analytes cited above, it can still serve as an useful indicator of the status of organic constituents in RMs.
Nakajima, Junichi; Ohno, Masashi; Chikama, Katsumi; Seki, Tatsuya; Oguma, Koichi
2009-09-15
A flow injection analysis (FIA) method using on-line separation and preconcentration with a novel metal scavenger beads, QuadraSil TA, has been developed for the ICP-OES determination of traces of palladium. QuadraSil TA contains diethylenetriamine as a functional group on spherical silica beads and shows the highest selectivity for Pd(II) at pH 1 (0.1 mol l(-1) hydrochloric acid) solution. An aliquot of the sample solution prepared as 0.1 mol l(-1) in hydrochloric acid was passed through the QuadraSil TA column. After washing the column with the carrier solution, the Pd(II) retained on the column was eluted with 0.05 mol l(-1) thiourea solution and the eluate was directly introduced into an ICP-OES. The proposed method was successfully applied to the determination of traces of palladium in JSd-2 stream sediment certified reference material [0.019+/-0.001 microg g(-1) (n=3); provisional value: 0.0212 microg g(-1)] and SRM 2556 used auto catalyst certified reference material [315+/-4 microg g(-1) (n=4); certified value: 326 microg g(-1)]. The detection limit (3 sigma) of 0.28 ng ml(-1) was obtained for 5 ml of sample solution. The sample through puts for 5 ml and 100 microl of the sample solutions were 10 and 15 h(-1), respectively.
NASA Astrophysics Data System (ADS)
Morgans, Courtney L.; Meijaard, Erik; Santika, Truly; Law, Elizabeth; Budiharta, Sugeng; Ancrenaz, Marc; Wilson, Kerrie A.
2018-06-01
Industrial oil palm plantations in South East Asia have caused significant biodiversity losses and perverse social outcomes. To address concerns over plantation practices and in an attempt to improve sustainability through market mechanisms, civil society organisations and industry representatives developed the Roundtable on Sustainable Palm Oil (RSPO) in 2004. The effectiveness of RSPO in improving the sustainability of the palm oil industry is frequently debated and to date, few quantitative analyses have been undertaken to assess how successful RSPO has been in delivering the social, economic and environmental sustainability outcomes it aims to address. With the palm oil industry continuing to expand in South East Asia and significant estates being planted in Africa and South America, this paper evaluates the effectiveness of RSPO plantations compared to non-certified plantations by assessing the relative performance of several key sustainability metrics compared to business as usual practices. Using Indonesian Borneo (Kalimantan) as a case study, a novel dataset of RSPO concessions was developed and causal analysis methodologies employed to evaluate the environmental, social and economic sustainability of the industry. No significant difference was found between certified and non-certified plantations for any of the sustainability metrics investigated, however positive economic trends including greater fresh fruit bunch yields were revealed. To achieve intended outcomes, RSPO principles and criteria are in need of substantial improvement and rigorous enforcement.
40 CFR 1033.255 - EPA decisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false EPA decisions. 1033.255 Section 1033.255 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Certifying Engine Families § 1033.255 EPA decisions. (a) If we...
40 CFR 1033.255 - EPA decisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false EPA decisions. 1033.255 Section 1033.255 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Certifying Engine Families § 1033.255 EPA decisions. (a) If we...
40 CFR 1033.255 - EPA decisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false EPA decisions. 1033.255 Section 1033.255 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Certifying Engine Families § 1033.255 EPA decisions. (a) If we...
40 CFR 1033.255 - EPA decisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false EPA decisions. 1033.255 Section 1033.255 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Certifying Engine Families § 1033.255 EPA decisions. (a) If we...
40 CFR 1033.255 - EPA decisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false EPA decisions. 1033.255 Section 1033.255 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Certifying Engine Families § 1033.255 EPA decisions. (a) If we...
Code of Federal Regulations, 2014 CFR
2014-07-01
... for Activities Conducted Under SAPs, COPs and GAPs § 585.800 How must I conduct my activities to.... (b) You must certify compliance with those terms and conditions identified in your approved SAP, COP...
Code of Federal Regulations, 2013 CFR
2013-07-01
... for Activities Conducted Under SAPs, COPs and GAPs § 585.800 How must I conduct my activities to.... (b) You must certify compliance with those terms and conditions identified in your approved SAP, COP...
Code of Federal Regulations, 2012 CFR
2012-07-01
... for Activities Conducted Under SAPs, COPs and GAPs § 585.800 How must I conduct my activities to.... (b) You must certify compliance with those terms and conditions identified in your approved SAP, COP...
40 CFR 203.7 - Post-certification testing.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Section 203.7 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS LOW-NOISE-EMISSION PRODUCTS § 203.7 Post-certification testing. The Administrator will, from time to time, as he deems appropriate, test the emissions of noise from certified low-noise-emission...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) MARINE... subject to this regulation, marine sanitation devices certified by the U.S. Coast Guard (see 33 CFR part... operated to prevent the overboard discharge of sewage, treated or untreated, or of any waste derived from...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) MARINE... subject to this regulation, marine sanitation devices certified by the U.S. Coast Guard (see 33 CFR part... operated to prevent the overboard discharge of sewage, treated or untreated, or of any waste derived from...
40 CFR 203.7 - Post-certification testing.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 203.7 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS LOW-NOISE-EMISSION PRODUCTS § 203.7 Post-certification testing. The Administrator will, from time to time, as he deems appropriate, test the emissions of noise from certified low-noise-emission...
40 CFR 1042.230 - Engine families.
Code of Federal Regulations, 2010 CFR
2010-07-01
... degree). (19) The type of smoke control system. (d) For Category 3 engines, group engines into engine....230 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Certifying Engine...
40 CFR 1042.230 - Engine families.
Code of Federal Regulations, 2014 CFR
2014-07-01
... degree). (19) The type of smoke control system. (d) For Category 3 engines, group engines into engine....230 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Certifying Engine...
40 CFR 1042.230 - Engine families.
Code of Federal Regulations, 2011 CFR
2011-07-01
... degree). (19) The type of smoke control system. (d) For Category 3 engines, group engines into engine....230 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Certifying Engine...
40 CFR 1042.230 - Engine families.
Code of Federal Regulations, 2012 CFR
2012-07-01
... degree). (19) The type of smoke control system. (d) For Category 3 engines, group engines into engine....230 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Certifying Engine...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Byerly, Benjamin L.; Stanley, Floyd; Spencer, Khal
In our study, a certified plutonium metal reference material (CRM 126) with a known production history is examined using analytical methods that are commonly employed in nuclear forensics for provenancing and attribution. Moreover, the measured plutonium isotopic composition and actinide assay are consistent with values reported on the reference material certificate. Model ages from U/Pu and Am/Pu chronometers agree with the documented production timeline. Finally, these results confirm the utility of these analytical methods and highlight the importance of a holistic approach for forensic study of unknown materials.
Investigation of fluorine content in PM2.5 airborne particles of Istanbul, Turkey.
Ozbek, Nil; Baltaci, Hakki; Baysal, Asli
2016-07-01
Fluorine determination in airborne samples is important due to its spread into the air from both natural and artificial sources. It can travel by wind over large distances before depositing on the Earth's surface. Its concentration in various matrices are limited and controlled by the regulations for causing health risks associated with environmental exposures. In this work, fluorine was determined in PM2.5 airborne samples by high-resolution continuum source electrothermal atomic absorption spectrometry. For these purpose, the PM2.5 airborne particulates were collected on quartz filters using high-volume samplers (500 L/min) in Istanbul (Turkey) for 96 h during January to June in 2 years. Then, instrumental and experimental parameters were optimized for the analyte in airborne samples. The validity of the method for the analyte was tested using standard reference material, and certified values were found in the limits of 95 % confidence level. The fluorine concentrations and meteorological conditions were compared statistically.
Vassileva, E; Baeten, H; Hoenig, M
2001-01-02
A slurry sampling-fast program procedure has been developed for the determination of arsenic in plants, soils and sediments by electrothermal atomic absorption spectrometry. Efficiencies of various single and mixed modifiers for thermal stabilization of arsenic and for a better removal of the matrix during pyrolysis step were compared. The influence of the slurry concentration, amounts of modifier and parameters of the pyrolysis step on the As integrated absorbance signals have been studied and a comparison between fast and conventional furnace programs was also made. The ultrasonic agitation of the slurry followed by a fast electrothermal program using an Ir/Mg modifier provides the most consistent performance in terms of precision and accuracy. The reliability of the whole procedure has been compared with results obtained after application of a wet digestion method with an HF step and validated by analyzing eleven certified reference materials. Arsenic detection and quantitation limits expressed on dry sample matter were about 30 and 100 micrograms kg-1, respectively.
Xu, Hongbo; Wu, Yun; Wang, Jian; Shang, Xuewei; Jiang, Xiaojun
2013-12-01
A new method that utilizes pretreated silica gel as an adsorbent has been developed for simultaneous preconcentration of trace Cd(II) and Pb(II) prior to the measurement by flame atomic absorption spectrometry. The effects of pH, the shaking time, the elution condition and the coexisting ions on the separation/preconcentration conditions of analytes were investigated. Under optimized conditions, the static adsorption capacity of Cd(II) and Pb(II) were 45.5 and 27.1mg/g, the relative standard deviations were 3.2% and 1.7% (for n = 11), and the limits of detection obtained were 4.25 and 0.60 ng/mL, respectively. The method was validated by analyzing the certified reference materials GBW 07304a (stream sediment) and successfully applied to the analysis of various treated wastewater samples with satisfactory results. Copyright © 2013 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.
Xiao, Ge; Saunders, David; Jones, Robert L.; Caldwell, Kathleen L.
2016-01-01
Quantification of 241Am in urine at low levels is important for assessment of individuals’ or populations’ accidental, environmental, or terrorism-related internal contamination, but no convenient, precise method has been established to rapidly determine these low levels. Here we report a new analytical method to measure 241Am as developed and validated at the Centers for Disease Control and Prevention (CDC) by means of the selective retention of Am from urine directly on DGA resin, followed by SF-ICP-MS detection. The method provides rapid results with a Limit of Detection (LOD) of 0.22 pg/L (0.028 Bq/L), which is lower than 1/3 of the C/P CDG for 241Am at 5 days post-exposure. The results obtained by this method closely agree with CDC values as measured by Liquid Scintillation Counting, and with National Institute of Standards Technology (NIST) Certified Reference Materials (CRM) target values. PMID:27375308
Xiao, Ge; Saunders, David; Jones, Robert L; Caldwell, Kathleen L
2016-07-01
Quantification of 241 Am in urine at low levels is important for assessment of individuals' or populations' accidental, environmental, or terrorism-related internal contamination, but no convenient, precise method has been established to rapidly determine these low levels. Here we report a new analytical method to measure 241 Am as developed and validated at the Centers for Disease Control and Prevention (CDC) by means of the selective retention of Am from urine directly on DGA resin, followed by SF-ICP-MS detection. The method provides rapid results with a Limit of Detection (LOD) of 0.22 pg/L (0.028 Bq/L), which is lower than 1/3 of the C/P CDG for 241 Am at 5 days post-exposure. The results obtained by this method closely agree with CDC values as measured by Liquid Scintillation Counting, and with National Institute of Standards Technology (NIST) Certified Reference Materials (CRM) target values.
De Boer, Jan L M; Ritsema, Rob; Piso, Sjoerd; Van Staden, Hans; Van Den Beld, Wilbert
2004-07-01
Two screening methods were developed for rapid analysis of a great number of urine and blood samples within the framework of an exposure check of the population after a firework explosion. A total of 56 elements was measured including major elements. Sample preparation consisted of simple dilution. Extensive quality controls were applied including element addition and the use of certified reference materials. Relevant results at levels similar to those found in the literature were obtained for Co, Ni, Cu, Zn, Sr, Cd, Sn, Sb, Ba, Tl, and Pb in urine and for the same elements except Ni, Sn, Sb, and Ba in blood. However, quadrupole ICP-MS has limitations, mainly related to spectral interferences, for the analysis of urine and blood, and these cause higher detection limits. The general aspects discussed in the paper give it wider applicability than just for analysis of blood and urine-it can for example be used in environmental analysis.
Lopes, Watson da Luz; Santelli, Ricardo Erthal; Oliveira, Eliane Padua; de Carvalho, Maria de Fátima Batista; Bezerra, Marcos Almeida
2009-10-15
A procedure has been developed for the determination of bioavailable concentrations of selenium and arsenic in estuarine sediments employing inductively coupled plasma optical emission spectrometry (ICP OES) using a concomitant metals analyzer device to perform hydride generation. The optimization of hydride generation was done in two steps: using a two-level factorial design for preliminary evaluation of studied factors and a Doehlert design to assess the optimal experimental conditions for analysis. Interferences of transition metallic ions (Cd(2+), Co(2+), Cu(2+), Fe(3+) and Ni(2+)) to selenium and arsenic signals were minimized by using higher hydrochloric acid concentrations. In this way, the procedure allowed the determination of selenium and arsenic in sediments with a detection limit of 25 and 30 microg kg(-1), respectively, assuming a 50-fold sample dilution (0.5 g sample extraction to 25 mL sample final volume). The precision, expressed as a relative standard deviation (% RSD, n=10), was 0.2% for both selenium and arsenic in 200 microg L(-1) solutions, which corresponds to 10 microg g(-1) in sediment samples after acid extraction. Applying the proposed procedure, a linear range of 0.08-10 and 0.10-10 microg g(-1) was obtained for selenium and arsenic, respectively. The developed procedure was validated by the analysis of two certified reference materials: industrial sludge (NIST 2782) and river sediment (NIST 8704). The results were in agreement with the certified values. The developed procedure was applied to evaluate the bioavailability of both elements in four sediment certified reference materials, in which there are not certified values for bioavailable fractions, and also in estuarine sediment samples collected in several sites of Guanabara Bay, an impacted environment in Rio de Janeiro, Brazil.
Zhu, Yanbei; Inagaki, Kazumi; Yarita, Takashi; Chiba, Koichi
2008-07-01
Microwave digestion and isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-SFMS) has been applied to the determination of Pb in rice flour. In order to achieve highly precise determination of low concentrations of Pb, the digestion blank for Pb was reduced to 0.21 ng g(-1) after optimization of the digestion conditions, in which 20 mL analysis solution was obtained after digestion of 0.5 g rice flour. The observed value of Pb in a non-fat milk powder certified reference material (CRM), NIST SRM 1549, was 16.8 +/- 0.8 ng g(-1) (mean +/- expanded uncertainty, k = 2; n = 5), which agreed with the certified value of 19 +/- 3 ng g(-1) and indicated the effectiveness of the method. Analytical results for Pb in three brown rice flour CRMs, NIST SRM 1568a, NIES CRM 10-a, and NIES CRM 10-b, were 7.32 +/- 0.24 ng g(-1) (n = 5), 1010 +/- 10 ng g(-1) (n = 5), and 1250 +/- 20 ng g(-1) (n = 5), respectively. The concentration of Pb in a candidate white rice flour reference material (RM) sample prepared by the National Metrology Institute of Japan (NMIJ) was observed to be 4.36 +/- 0.28 ng g(-1) (n = 10 bottles).
The determination of mercury in mushrooms by CV-AAS and ICP-AES techniques.
Jarzynska, Grazyna; Falandysz, Jerzy
2011-01-01
This research presents an example of an excellent applied study on analytical problems due to hazardous mercury determination in environmental materials and validity of published results on content of this element in wild growing mushrooms. The total mercury content has been analyzed in a several species of wild-grown mushrooms and some herbal origin certified reference materials, using two analytical methods. One method was commonly known and well validated the cold-vapour atomic absorption spectroscopy (CV-AAS) after a direct sample pyrolysis coupled to the gold wool trap, which was a reference method. A second method was a procedure that involved a final mercury measurement using the inductively-coupled plasma atomic emission spectroscopy (ICP-AES) at λ 194.163 nm, which was used by some authors to report on a high mercury content of a large sets of wild-grown mushrooms. We found that the method using the ICP-AES at λ 194.163 nm gave inaccurate and imprecise results. The results of this study imply that because of unsuitability of total mercury determination using the ICP-AES at λ 194.163 nm, the reports on great concentrations of this metal in a large sets of wild-grown mushrooms, when examined using this method, have to be studied with caution, since data are highly biased.
Thomas, Jeanice B; Duewer, David L; Mugenya, Isaac O; Phinney, Karen W; Sander, Lane C; Sharpless, Katherine E; Sniegoski, Lorna T; Tai, Susan S; Welch, Michael J; Yen, James H
2012-01-01
Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.
49 CFR 536.5 - Trading infrastructure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 6 2012-10-01 2012-10-01 false Trading infrastructure. 536.5 Section 536.5... infrastructure. (a) Accounts. NHTSA maintains “accounts” for each credit holder. The account consists of a... the certified and reported CAFE data provided by the Environmental Protection Agency for enforcement...
49 CFR 536.5 - Trading infrastructure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 6 2014-10-01 2014-10-01 false Trading infrastructure. 536.5 Section 536.5... infrastructure. (a) Accounts. NHTSA maintains “accounts” for each credit holder. The account consists of a... the certified and reported CAFE data provided by the Environmental Protection Agency for enforcement...
49 CFR 536.5 - Trading infrastructure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 6 2013-10-01 2013-10-01 false Trading infrastructure. 536.5 Section 536.5... infrastructure. (a) Accounts. NHTSA maintains “accounts” for each credit holder. The account consists of a... the certified and reported CAFE data provided by the Environmental Protection Agency for enforcement...
40 CFR 121.21 - When Administrator certifies.
Code of Federal Regulations, 2011 CFR
2011-07-01
... activity requiring a license or permit will not violate applicable water quality standards will be required... respect to those water quality standards promulgated by him; or (b) Water quality standards have been... Section 121.21 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS STATE...
40 CFR 121.21 - When Administrator certifies.
Code of Federal Regulations, 2010 CFR
2010-07-01
... activity requiring a license or permit will not violate applicable water quality standards will be required... respect to those water quality standards promulgated by him; or (b) Water quality standards have been... Section 121.21 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS STATE...
Environmental testing philosophy for a Sandia National Laboratories small satellite project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cap, J.S.; Rackley, N.G.
1996-03-01
Sandia National Laboratories is the system integrator on a small satellite project. Following the intent of the NASA GEVS document, an integrated test philosophy was formulated to certify the satellite for flight. The purpose of this paper is to present that philosophy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Training. 68.71 Section 68.71 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CHEMICAL... June 21, 1999 an owner or operator may certify in writing that the employee has the required knowledge...
40 CFR 60.273a - Emission monitoring.
Code of Federal Regulations, 2013 CFR
2013-07-01
... following: (1) Inspecting the baghouse for air leaks, torn or broken bags or filter media, or any other....273a Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... by a certified visible emission observer and the owner installs and continuously operates a bag leak...
40 CFR 60.273a - Emission monitoring.
Code of Federal Regulations, 2014 CFR
2014-07-01
... following: (1) Inspecting the baghouse for air leaks, torn or broken bags or filter media, or any other....273a Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... by a certified visible emission observer and the owner installs and continuously operates a bag leak...
40 CFR 60.273a - Emission monitoring.
Code of Federal Regulations, 2012 CFR
2012-07-01
... following: (1) Inspecting the baghouse for air leaks, torn or broken bags or filter media, or any other....273a Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... by a certified visible emission observer and the owner installs and continuously operates a bag leak...
Are green building features safe for preventive maintenance workers? Examining the evidence.
Omar, Mohamed Shamun; Quinn, Margaret M; Buchholz, Bryan; Geiser, Ken
2013-04-01
Many newly constructed green buildings (GB) are certified using the United States Green Building Council (USGBC) Leadership in Energy and Environmental Design (LEED) rating system for new construction and major renovation which focuses on architectural and mechanical design to conserve energy, reduce environmental harm, and enhance indoor quality for occupants. This study evaluated the preventive maintenance (PM) worker occupational safety and health (OSH) risks related to the design of GB. PM job hazard analyses (JHA) were performed on the tasks required to operate and maintain five GB features selected from 13 LEED certified GB. A 22-item JHA and OSH risk scoring system were developed. Potentially serious OSH hazards included: green roofs made of slippery material without fall protection; energy recovery wheels and storm water harvesting systems in confined spaces; skylights without guard rails; and tight geothermal well mechanical rooms constraining safe preventive practices. GB can present PM OSH risks and these should be eliminated in the building design phase. Copyright © 2013 Wiley Periodicals, Inc.
Alothman, Zeid A; Habila, Mohamed; Yilmaz, Erkan; Soylak, Mustafa
2013-01-01
A simple, environmentally friendly, and efficient dispersive liquid-liquid microextraction method combined with microsample injection flame atomic absorption spectrometry was developed for the separation and preconcentration of Cu(II). 2-(5-Bromo-2-pyridylazo)-5-(diethylamino)phenol (5-Br-PADAP) was used to form a hydrophobic complex of Cu(II) ions in the aqueous phase before extraction. To extract the Cu(II)-5-Br-PADAP complex from the aqueous phase to the organic phase, 2.0 mL of acetone as a disperser solvent and 200 microL of chloroform as an extraction solvent were used. The influences of important analytical parameters, such as the pH, types and volumes of the extraction and disperser solvents, amount of chelating agent, sample volume, and matrix effects, on the microextraction procedure were evaluated and optimized. Using the optimal conditions, the LOD, LOQ, preconcentration factor, and RSD were determined to be 1.4 microg/L, 4.7 microg/L, 120, and 6.5%, respectively. The accuracy of the proposed method was investigated using standard addition/recovery tests. The analysis of certified reference materials produced satisfactory analytical results. The developed method was applied for the determination of Cu in real samples.
NASA Astrophysics Data System (ADS)
Huang, Keke; Li, Ming; Li, Hongmei; Li, Mengwan; Jiang, You; Fang, Xiang
2016-01-01
Ambient ionization (AI) techniques have been widely used in chemistry, medicine, material science, environmental science, forensic science. AI takes advantage of direct desorption/ionization of chemicals in raw samples under ambient environmental conditions with minimal or no sample preparation. However, its quantitative accuracy is restricted by matrix effects during the ionization process. To improve the quantitative accuracy of AI, a matrix reference material, which is a particular form of measurement standard, was coupled to an AI technique in this study. Consequently the analyte concentration in a complex matrix can be easily quantified with high accuracy. As a demonstration, this novel method was applied for the accurate quantification of creatinine in serum by using extractive electrospray ionization (EESI) mass spectrometry. Over the concentration range investigated (0.166 ~ 1.617 μg/mL), a calibration curve was obtained with a satisfactory linearity (R2 = 0.994), and acceptable relative standard deviations (RSD) of 4.6 ~ 8.0% (n = 6). Finally, the creatinine concentration value of a serum sample was determined to be 36.18 ± 1.08 μg/mL, which is in excellent agreement with the certified value of 35.16 ± 0.39 μg/mL.
30 CFR 250.1015 - Applications for pipeline right-of-way grants.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... 250.1015 Section 250.1015 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND... accompanied by a certified copy of the articles of association or appropriate reference to a copy of such articles already filed with MMS and a statement as to any subsequent amendments. (3) If the applicant is a...
25 CFR 542.3 - How do I comply with this part?
Code of Federal Regulations, 2014 CFR
2014-04-01
... accountant's audit report to achieve compliance with the requirements of the new tier. (2) The Tribal gaming... Commission pursuant to 25 CFR 522.3(b). (f) CPA testing. (1) An independent certified public accountant (CPA... completed. Work-paper references are suggested for all “no” responses for the results obtained during...
25 CFR 542.3 - How do I comply with this part?
Code of Federal Regulations, 2013 CFR
2013-04-01
... accountant's audit report to achieve compliance with the requirements of the new tier. (2) The Tribal gaming... Commission pursuant to 25 CFR 522.3(b). (f) CPA testing. (1) An independent certified public accountant (CPA... completed. Work-paper references are suggested for all “no” responses for the results obtained during...
29 CFR 1650.206 - Notification to Treasury.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION DEBT COLLECTION Procedures... referring a debt to Treasury, EEOC will certify that the debt meets all of the requirements in § 1650.202..., the amount of the debt, the date on which the debt became past-due, and the designation of EEOC as the...
29 CFR 1650.206 - Notification to Treasury.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION DEBT COLLECTION Procedures... referring a debt to Treasury, EEOC will certify that the debt meets all of the requirements in § 1650.202..., the amount of the debt, the date on which the debt became past-due, and the designation of EEOC as the...
29 CFR 1650.206 - Notification to Treasury.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION DEBT COLLECTION Procedures... referring a debt to Treasury, EEOC will certify that the debt meets all of the requirements in § 1650.202..., the amount of the debt, the date on which the debt became past-due, and the designation of EEOC as the...
29 CFR 1650.206 - Notification to Treasury.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION DEBT COLLECTION Procedures... referring a debt to Treasury, EEOC will certify that the debt meets all of the requirements in § 1650.202..., the amount of the debt, the date on which the debt became past-due, and the designation of EEOC as the...
29 CFR 1650.206 - Notification to Treasury.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION DEBT COLLECTION Procedures... referring a debt to Treasury, EEOC will certify that the debt meets all of the requirements in § 1650.202..., the amount of the debt, the date on which the debt became past-due, and the designation of EEOC as the...
Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook
2010-09-01
Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p < .0001), but clinically relevant discrepancies were found in 13.3% of patients. IRMA-3, which claims to be standardized to CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.
NASA Astrophysics Data System (ADS)
Matos Reyes, M. N.; Cervera, M. L.; Campos, R. C.; de la Guardia, M.
2007-09-01
A fast, sensitive and simple non-chromatographic analytical method was developed for the speciation analysis of toxic arsenic species in cereal samples, namely rice and wheat semolina. An ultrasound-assisted extraction of the toxic arsenic species was performed with 1 mol L - 1 H 3PO 4 and 0.1% (m/v) Triton XT-114. After extraction, As(III), As(V), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) concentrations were determined by hydride generation atomic fluorescence spectrometry using a series of proportional equations corresponding to four different experimental reduction conditions. The detection limits of the method were 1.3, 0.9, 1.5 and 0.6 ng g - 1 for As(III), As(V), DMA and MMA, respectively, expressed in terms of sample dry weight. Recoveries were always greater than 90%, and no species interconversion occurred. The speciation analysis of a rice flour reference material certified for total arsenic led to coherent results, which were also in agreement with other speciation studies made on the same certified reference material.
Ong, E S; Yong, Y L; Woo, S O
1999-01-01
A simple, rapid, and sensitive method with high sample throughput was developed for determining arsenic in traditional Chinese medicine (TCM) in the form of uncoated tablets, sugar-coated tablets, black pills, capsules, powders, and syrups. The method involves microwave digestion with flow injection-inductively coupled plasma mass spectrometry (FI-ICP-MS). Method precision was 2.7-10.1% (relative standard deviation, n = 6) for different concentrations of arsenic in different TCM samples analyzed by different analysts on different days. Method accuracy was checked with a certified reference material (sea lettuce, Ulva lactuca, BCR CRM 279) for external calibration and by spiking arsenic standard into different TCMs. Recoveries of 89-92% were obtained for the certified reference material and higher than 95% for spiked TCMs. Matrix interference was insignificant for samples analyzed by the method of standard addition. Hence, no correction equation was used in the analysis of arsenic in the samples studied. Sample preparation using microwave digestion gave results that were very similar to those obtained by conventional wet acid digestion using nitric acid.
NASA Astrophysics Data System (ADS)
Acharya, R.; Swain, K. K.; Reddy, A. V. R.
2010-10-01
Three synthetic multielement standards (SMELS I, II and III) and two reference materials (RMs), SL-3 and Soil-7 of IAEA were analyzed for validation of the k0-based internal monostandard neutron activation analysis (IM-NAA) method utilizing in-situ relative detection efficiency. The internal monostandards used in SMELS and RMs were Au and Sc, respectively. The samples were irradiated in Apsara and Dhruva reactors, BARC and radioactive assay was carried out using a 40% relative efficiency HPGe detector coupled to an 8 k MCA. Concentrations of 23 elements were determined in both SMELS and RMs. In the case of RMs, concentrations of a few elements, whose certified values are not available, could also be determined. The % deviations for the elements determined in SMELS with respect to the assigned values and RMs with respect to certified values were within ±8%. The Z-score values at 95% confidence level for most of the elements in both the materials were within ±1.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 6 2014-07-01 2014-07-01 false EPA testing. 59.630 Section 59.630 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Emissions From New and In-Use Portable Fuel Containers Certifying Emission Families § 59.630 EPA testing. We...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 6 2013-07-01 2013-07-01 false EPA testing. 59.630 Section 59.630 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Emissions From New and In-Use Portable Fuel Containers Certifying Emission Families § 59.630 EPA testing. We...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 5 2011-07-01 2011-07-01 false EPA testing. 59.630 Section 59.630 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Emissions From New and In-Use Portable Fuel Containers Certifying Emission Families § 59.630 EPA testing. We...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 6 2012-07-01 2012-07-01 false EPA testing. 59.630 Section 59.630 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Emissions From New and In-Use Portable Fuel Containers Certifying Emission Families § 59.630 EPA testing. We...
40 CFR 1045.230 - How do I select engine families?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false How do I select engine families? 1045.230 Section 1045.230 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Certifying...
40 CFR 1045.230 - How do I select engine families?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false How do I select engine families? 1045.230 Section 1045.230 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Certifying...
40 CFR 1045.230 - How do I select engine families?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false How do I select engine families? 1045.230 Section 1045.230 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Certifying...
40 CFR 1045.230 - How do I select engine families?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false How do I select engine families? 1045.230 Section 1045.230 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Certifying...
40 CFR 1045.230 - How do I select engine families?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false How do I select engine families? 1045.230 Section 1045.230 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Certifying...
ERIC Educational Resources Information Center
Clark, Bob
2006-01-01
Green cleaning is gaining momentum. It is a method of cleaning and maintaining facilities that is friendly to the environment and healthful for students and staff. The process uses environmentally friendly and nontoxic cleaning products and practices that must be third-party-certified. Using green cleaning practices and products can result in…
New gasoline regulations require annual attestations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leger, M.W.; Lott, L.H.
1995-03-27
The US Environmental Protection Agency's new reformulated fuels regulations impose a myriad of new record keeping and reporting requirements, in addition to the new quality standards. These requirements include an annual procedures review, or attestation. The attestation is part of EPA's enforcement plan and is required of all refiners, importers, and oxygenate blenders. This annual report is due May 31 of the year following the covered period and must be performed by a certified public accountant or a certified internal auditor. The attestation procedure is too complicated and detailed to be explained fully here, but the main points covered bymore » the attestation are outlined to inform refiners who may be unaware of the requirements.« less
Sikder, Shegufta S; Labrique, Alain B; Ullah, Barkat; Mehra, Sucheta; Rashid, Mahbubur; Ali, Hasmot; Jahan, Nusrat; Shamim, Abu A; West, Keith P; Christian, Parul
2012-08-15
Though non-communicable diseases contribute to an increasing share of the disease burden in South Asia, health systems in most rural communities are ill-equipped to deal with chronic illness. This analysis seeks to describe care-seeking behavior among women of reproductive age who died from fatal non-communicable diseases as recorded in northwest rural Bangladesh between 2001 and 2007. This analysis utilized data from a large population-based cohort trial in northwest rural Bangladesh. To conduct verbal autopsies of women who died while under study surveillance, physicians interviewed family members to elicit the biomedical symptoms that the women experienced as well as a narrative of the events leading to deaths. We performed qualitative textual analysis of verbal autopsy narratives for 250 women of reproductive age who died from non-communicable diseases between 2001 and 2007. The majority of women (94%) sought at least one provider for their illnesses. Approximately 71% of women first visited non-certified providers such as village doctors and traditional healers, while 23% first sought care from medically certified providers. After the first point of care, women appeared to switch to medically certified practitioners when treatment from non-certified providers failed to resolve their illness. This study suggests that treatment seeking patterns for non-communicable diseases are affected by many of the sociocultural factors that influence care seeking for pregnancy-related illnesses. Families in northwest rural Bangladesh typically delayed seeking treatment from medically certified providers for NCDs due to the cost of services, distance to facilities, established relationships with non-certified providers, and lack of recognition of the severity of illnesses. Most women did not realize initially that they were suffering from a chronic illness. Since women typically reached medically certified providers in advanced stages of disease, they were usually told that treatment was not possible or were referred to higher-level facilities that they could not afford to visit. Women suffering from non-communicable disease in these rural communities need feasible and practical treatment options. Further research and investment in adequate, appropriate care seeking and referral is needed for women of reproductive age suffering from fatal non-communicable diseases in resource-poor settings.
NASA Astrophysics Data System (ADS)
Ecker, K. H.; Wätjen, U.; Berger, A.; Persson, L.; Pritzkow, W.; Radtke, M.; Riesemeier, H.
2002-04-01
A layer of Sb atoms, implanted with an energy of 400 keV and a nominal dose of 5×10 16 atoms/cm 2 into a high purity silicon wafer, was certified for its areal density (atoms/cm 2) using Rutherford backscattering spectrometry (RBS), instrumental neutron activation analysis (INAA) and inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) and for its isotope ratio using INAA and ICP-IDMS. Excellent agreement between the results of the different independent methods was found. In the present work, the measurements of the homogeneity of the areal density of Sb, previously determined with RBS in spots having 1 mm diameter, are improved with synchrotron X-ray fluorescence analysis: Higher precision in even smaller sample spots allows to estimate a reduced inhomogeneity of the whole batch of samples of the order of only 0.4%. Thus the uncertainty of the certified value can further be reduced. Down to fractions of a chip with 0.3×0.4 mm 2 area, the areal density is now certified as (4.81±0.06)×10 16 Sb atoms/cm 2, where the expanded uncertainty 0.06 (coverage factor k=2) corresponds to only 1.2%. The relative merits of the different analytical methods are discussed.
Navarro, P; Cortazar, E; Bartolomé, L; Deusto, M; Raposo, J C; Zuloaga, O; Arana, G; Etxebarria, N
2006-09-22
The feasibility of different clean-up procedures was studied for the determination of polycyclic aromatic hydrocarbons (PAHs) in biota samples such as oysters, mussels and fish liver. In this sense, once the samples were extracted--essentially with acetone and in a microwave system--and before they could be analysed by gas chromatography-mass spectrometry (GC-MS), three different approaches were studied for the clean-up step: solid phase extraction (SPE), microwave-assisted saponification (MAS) and gel permeation chromatography (GPC). The main aim of this work was to maximise the recoveries of PAHs and to minimise the presence of interfering compounds in the last extract. In the case of SPE, Florisil cartridges of 1, 2 and 5 g, and silica cartridges of 5 g were studied. In that case, and with oysters and mussels, microwave-assisted extraction and 5 g Florisil cartridges provided good results. In addition, the concentrations obtained for Standard Reference Material (SRM) NIST 2977 (mussel tissue) were in good agreement with the certified values. In the case of microwave-assisted saponification, the extracts were not as clean as those obtained with 5 g Florisil and this fact lead to overestimate the concentration of the heaviest PAHs. Finally, the cleanest extracts were obtained by GPC. The method was successfully applied to mussels, oysters and hake liver, and the results obtained for NIST 2977 (mussel tissue) were within the confidence interval of the certified reference material for most of the certified analytes.
Shang, Xiaohong; Zhao, Yunfeng; Zhang, Lei; Li, Xiaowei; Wu, Yongning
2011-07-01
The improvement method was developed for methylmercury determination using liquid chromatography online coupled with cold vapor atomic fluorescence spectrometry (LC-CV-AFS). Cysteine was used as complexing agent in mobile phase instead of mercaptoethanol. Under the optimized conditions, baseline separation of mercury species could be achieved within 8 min on a C18 column with a mobile phase of 5% (v/v) acetonitrile-1 g/L L-cysteine-50 mmol/L ammonium acetate aqueous solution. The linear range of calibration curve of methylmercury was 1-50 microg/L and the limit of detection (S/N = 3) for methylmercury was 0.3 microg/L. Ultrasonication assisted hydrochloric acid extraction was used to extract methylmercury from seafood samples. The sample extract was cleaned up by a C18 solid phase extraction (SPE) cartridge. For validation of the method, certified reference materials and spiked seafood samples were analyzed. The determined methylmercury contents of certified reference materials NIST1566b, BCR464 and GBW10029 agreed well with the certified values. The determined methylmercury values for Food Analysis Performance Assessment Scheme (FAPAS) sample 07115 were satisfied. The recoveries of methylmercury in seafood samples at three spiked levels (10, 50 and 500 microg/kg) ranged from 89% to 112%, including cooked seafood food. The precision of the method based on relative standard deviation (RSD) was not more than 7%. The present method of LC-CV-AFS is accurate, sensitive, simple, and can meet the demand of methylmercury determination in seafood.
Code of Federal Regulations, 2013 CFR
2013-07-01
... certified to meet U.S. EPA standards for a useful-life period of XXX miles or XXX hours of operation... engine has a primary intended service application as a XXX heavy-duty engine.” (The primary intended... appropriate model year U.S. Environmental Protection Agency regulations which apply to XXX-fueled heavy-duty...
7 CFR 4279.43 - Certified Lender Program.
Code of Federal Regulations, 2011 CFR
2011-01-01
... complete financial statements; and completion by the Agency of the environmental analysis. The Agency may... lender will provide a written certification to this effect along with a statistical analysis of its... 80 percent. (4) If the lender is a bank or savings and loan, it must have a financial strength rating...
7 CFR 4279.43 - Certified Lender Program.
Code of Federal Regulations, 2013 CFR
2013-01-01
... complete financial statements; and completion by the Agency of the environmental analysis. The Agency may... lender will provide a written certification to this effect along with a statistical analysis of its... 80 percent. (4) If the lender is a bank or savings and loan, it must have a financial strength rating...
7 CFR 4279.43 - Certified Lender Program.
Code of Federal Regulations, 2014 CFR
2014-01-01
... complete financial statements; and completion by the Agency of the environmental analysis. The Agency may... lender will provide a written certification to this effect along with a statistical analysis of its... 80 percent. (4) If the lender is a bank or savings and loan, it must have a financial strength rating...
7 CFR 4279.43 - Certified Lender Program.
Code of Federal Regulations, 2012 CFR
2012-01-01
... complete financial statements; and completion by the Agency of the environmental analysis. The Agency may... lender will provide a written certification to this effect along with a statistical analysis of its... 80 percent. (4) If the lender is a bank or savings and loan, it must have a financial strength rating...
40 CFR 1045.205 - What must I include in my application?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false What must I include in my application? 1045.205 Section 1045.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Certifying...
40 CFR 1045.205 - What must I include in my application?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What must I include in my application? 1045.205 Section 1045.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Certifying...
40 CFR 1045.205 - What must I include in my application?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false What must I include in my application? 1045.205 Section 1045.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Certifying...
40 CFR 1045.205 - What must I include in my application?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false What must I include in my application? 1045.205 Section 1045.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Certifying...
24 CFR 58.71 - Request for release of funds and certification.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Certifying Officer. The request shall describe the specific project and activities covered by the request and... entity with all available project and environmental information and refrain from undertaking any physical activities or choice limiting actions until HUD (or the State, if applicable) has approved its request for...
24 CFR 58.71 - Request for release of funds and certification.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Certifying Officer. The request shall describe the specific project and activities covered by the request and... entity with all available project and environmental information and refrain from undertaking any physical activities or choice limiting actions until HUD (or the State, if applicable) has approved its request for...
Socially Responsible Investing: It's Time for Schools to Get on Board
ERIC Educational Resources Information Center
Armoza, Natalia
2011-01-01
Whether it is in their professional development programs, admissions materials, or curricula, independent schools have a lot to say about environmental stewardship, equity, community service, and justice. When they send their students to rebuild post-Katrina New Orleans or construct LEED-certified structures, the schools and their constituents…
Small Changes Won't Assure Sustainability--but Reimagining Might
ERIC Educational Resources Information Center
Holdaway, Xarissa
2008-01-01
Almost every day, the author learns about new green buildings from press releases. One example is that of Arizona State University's new Biodesign Institute, a soaring, "uber"-chic, high-performance, Leadership in Energy and Environmental Design-certified center. However, the author maintains that such buildings are undoubtedly a step up…
40 CFR 94.11 - Requirements for rebuilding certified engines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... person familiar with the design and function of motor vehicle engines would reasonably believe that the... Engine Book of Record Parameters. [64 FR 73331, Dec. 29, 1999, as amended at 68 FR 9784, Feb. 28, 2003] ... engines. 94.11 Section 94.11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...
40 CFR 1054.610 - What is the exemption for delegated final assembly?
Code of Federal Regulations, 2013 CFR
2013-07-01
... final assembly? 1054.610 Section 1054.610 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... EQUIPMENT Special Compliance Provisions § 1054.610 What is the exemption for delegated final assembly? The provisions of 40 CFR 1068.261 related to delegated final assembly do not apply for handheld engines certified...
40 CFR 1054.610 - What is the exemption for delegated final assembly?
Code of Federal Regulations, 2012 CFR
2012-07-01
... final assembly? 1054.610 Section 1054.610 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... EQUIPMENT Special Compliance Provisions § 1054.610 What is the exemption for delegated final assembly? The provisions of 40 CFR 1068.261 related to delegated final assembly do not apply for handheld engines certified...
40 CFR 1054.610 - What is the exemption for delegated final assembly?
Code of Federal Regulations, 2010 CFR
2010-07-01
... final assembly? 1054.610 Section 1054.610 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... EQUIPMENT Special Compliance Provisions § 1054.610 What is the exemption for delegated final assembly? The provisions of 40 CFR 1068.261 related to delegated final assembly do not apply for handheld engines certified...
40 CFR 1054.610 - What is the exemption for delegated final assembly?
Code of Federal Regulations, 2011 CFR
2011-07-01
... final assembly? 1054.610 Section 1054.610 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... EQUIPMENT Special Compliance Provisions § 1054.610 What is the exemption for delegated final assembly? The provisions of 40 CFR 1068.261 related to delegated final assembly do not apply for handheld engines certified...
40 CFR 1054.610 - What is the exemption for delegated final assembly?
Code of Federal Regulations, 2014 CFR
2014-07-01
... final assembly? 1054.610 Section 1054.610 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... EQUIPMENT Special Compliance Provisions § 1054.610 What is the exemption for delegated final assembly? The provisions of 40 CFR 1068.261 related to delegated final assembly do not apply for handheld engines certified...
USDA-ARS?s Scientific Manuscript database
The introduction of drift reduction technology (DRT) guidelines by the U. S. Environmental Protection Agency (EPA) has established testing protocols for nozzles, agrochemicals, application parameters, and combinations thereof for applying agrochemicals by certified individuals in the United States....
76 FR 39998 - Semiannual Regulatory Agenda, Spring 2011
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-07
.... It would change the definition of high-risk animal, which will change the types of animals eligible..., subject to the availability of appropriated funds, receive payments for certified citrus nursery stock... 3271 Environmental Impact Statement. Comment Period End 03/23/04 Notice of Availability of Draft 07/17...
46 CFR 62.20-5 - Self-certification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Self-certification. 62.20-5 Section 62.20-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Plan... certify to the Coast Guard, in writing, that the automation is designed to meet the environmental design...
40 CFR 1045.205 - What must I include in my application?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What must I include in my application? 1045.205 Section 1045.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Certifying...
40 CFR 85.1505 - Final admission of certified vehicles.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... 85.1505 Section 85.1505 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Importation of Motor Vehicles and Motor... vehicle or engine from the previous test (e.g., adjusting the RPM, timing, air-to-fuel ratio, etc.) other...
Serra, H; Nogueira, J M F
2005-11-11
In the present contribution, a new automated on-line hydride generation methodology was developed for dibutyltin and tributyltin speciation at the trace level, using a programmable temperature-vaporizing inlet followed by capillary gas chromatography coupled to mass spectrometry in the selected ion-monitoring mode acquisition (PTV-GC/MS(SIM)). The methodology involves a sequence defined by two running methods, the first one configured for hydride generation with sodium tetrahydroborate as derivatising agent and the second configured for speciation purposes, using a conventional autosampler and data acquisition controlled by the instrument's software. From the method-development experiments, it had been established that injector configuration has a great effect on the speciation of the actual methodology, particularly, the initial inlet temperature (-20 degrees C; He: 150 ml/min), injection volume (2 microl) and solvent characteristics using the solvent venting mode. Under optimized conditions, a remarkable instrumental performance including very good precision (RSD < 4%), excellent linear dynamic range (up to 50 microg/ml) and limits of detection of 0.12 microg/ml and 9 ng/ml, were obtained for dibutyltin and tributyltin, respectively. The feasibility of the present methodology was validated through assays upon in-house spiked water (2 ng/ml) and a certified reference sediment matrix (Community Bureau of Reference, CRM 462, Nr. 330 dibutyltin: 68+/-12 ng/g; tributyltin: 54+/-15 ng/g on dry mass basis), using liquid-liquid extraction (LLE) and solid-phase extraction (SPE) sample enrichment and multiple injections (2 x 5 microl) for sensitivity enhancement. The methodology evidenced high reproducibility, is easy to work-up, sensitive and showed to be a suitable alternative to replace the currently dedicated analytical systems for organotin speciation in environmental matrices at the trace level.
Forensic investigation of plutonium metal: a case study of CRM 126
Byerly, Benjamin L.; Stanley, Floyd; Spencer, Khal; ...
2016-11-01
In our study, a certified plutonium metal reference material (CRM 126) with a known production history is examined using analytical methods that are commonly employed in nuclear forensics for provenancing and attribution. Moreover, the measured plutonium isotopic composition and actinide assay are consistent with values reported on the reference material certificate. Model ages from U/Pu and Am/Pu chronometers agree with the documented production timeline. Finally, these results confirm the utility of these analytical methods and highlight the importance of a holistic approach for forensic study of unknown materials.
Lemes, Pedro Guilherme; Zanuncio, José Cola; Serrão, José Eduardo; Lawson, Simon A
2017-01-01
The Forest Stewardship Council (FSC) was the first non-governmental organization composed of multi-stakeholders to ensure the social, environmental, and economic sustainability of forest resources. FSC prohibits certain chemicals and active ingredients in certified forest plantations. A company seeking certification must discontinue use of products so listed and many face problems to comply with these constraints. The aim of this study was to assess the impacts of certification on pest management from the perspective of Brazilian private forestry sector. Ninety-three percent of Brazilian FSC-certified forest companies rated leaf-cutting ants as "very important" pests. Chemical control was the most important management technique used and considered very important by 82 % of respondents. The main chemical used to control leaf-cutting ants, sulfluramid, is in the derogation process and was classified as very important by 96.5 % of the certified companies. Certified companies were generally satisfied in relation to FSC certification and the integrated management of forest pests, but 27.6 % agreed that the prohibitions of pesticides for leaf-cutting ant and termite control could be considered as a non-tariff barrier on high-productivity Brazilian forest plantations. FSC forest certification has encouraged the implementation of more sustainable techniques and decisions in pest management in forest plantations in Brazil. The prohibition on pesticides like sulfluramid and the use of alternatives without the same efficiency will result in pest mismanagement, production losses, and higher costs. This work has shown that the application of global rules for sustainable forest management needs to adapt to each local reality.
76 FR 59769 - Clarification on the Division 1.1 Fireworks Approvals Policy
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-27
... test laboratory if the firework device is manufactured in accordance with APA Standard 87-1 (IBR, see... certify that the firework device conforms to the APA Standard 87-1 and that the descriptions and technical... issuing the EX approval. While APA Standard 87-1 references two instances where Division 1.1 fireworks may...
Sen. Gillibrand, Kirsten E. [D-NY
2010-03-16
Senate - 03/16/2010 Read twice and referred to the Committee on Agriculture, Nutrition, and Forestry. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Basic Camp Management: An Introduction to Camp Administration. Revised 3rd Edition.
ERIC Educational Resources Information Center
Ball, Armand; Ball, Beverly
This book is the primary text for the Certified Camp Director Program and the Basic Camp Directors Course sponsored by the American Camping Association (Indiana). It provides an orientation for new and prospective camp directors and a quick reference for experienced camp directors. The book covers the following topics: (1) an historical overview…
40 CFR 86.1808-07 - Maintenance instructions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... reference see §§ 86.1 and 86.1808-1. (g) For each new diesel-fueled Tier 2 vehicle (certified using a test fuel with 15 ppm sulfur or less), the manufacturer shall furnish or cause to be furnished to the purchaser a statement that “This vehicle must be operated only with ultra low sulfur diesel fuel (that is...
40 CFR 86.1808-07 - Maintenance instructions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... reference see §§ 86.1 and 86.1808-1. (g) For each new diesel-fueled Tier 2 vehicle (certified using a test fuel with 15 ppm sulfur or less), the manufacturer shall furnish or cause to be furnished to the purchaser a statement that “This vehicle must be operated only with ultra low sulfur diesel fuel (that is...
40 CFR 86.1808-07 - Maintenance instructions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... reference see §§ 86.1 and 86.1808-1. (g) For each new diesel-fueled Tier 2 vehicle (certified using a test fuel with 15 ppm sulfur or less), the manufacturer shall furnish or cause to be furnished to the purchaser a statement that “This vehicle must be operated only with ultra low sulfur diesel fuel (that is...
40 CFR 86.1808-07 - Maintenance instructions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... reference see §§ 86.1 and 86.1808-1. (g) For each new diesel-fueled Tier 2 vehicle (certified using a test fuel with 15 ppm sulfur or less), the manufacturer shall furnish or cause to be furnished to the purchaser a statement that “This vehicle must be operated only with ultra low sulfur diesel fuel (that is...
A Certified Stamp of Approval: How Important Are IT Certifications?
ERIC Educational Resources Information Center
Raths, David
2010-01-01
In the world of campus IT hiring, think of certifications as the equivalent of the SATs. They're just one component of the overall application, along with the interview, past performance, and references. If the candidate is accomplished and well rounded, the SATs--or certifications--can be more of a checklist item. Otherwise, they may make the…
76 FR 46893 - Agency Information Collection Activity Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-03
... manufacturer certifies to a FTA grantee that the bus the grantee is purchasing has been tested at the Center. Also, grantees about to purchase a bus use this report to assist them in making their purchasing decisions. PTI maintains a reference file for all the test reports which are made available to the public...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-02
... Control Specialists would no longer be required to certify they have not been involved in an operational error (OE), operational deviation (OD), or runway incursion in the past 5 years. The proposed change... references to employee identification, training record entries, performance management, and return-to-duty...
Copper Oxide Precipitates in NBS Standard Reference Material 482
Windsor, Eric S.; Carlton, Robert A.; Gillen, Greg; Wight, Scott A.; Bright, David S.
2002-01-01
Copper oxide has been detected in the copper containing alloys of NBS Standard Reference Material (SRM) 482. This occurrence is significant because it represents heterogeneity within a standard reference material that was certified to be homogeneous on a micrometer scale. Oxide occurs as elliptically to spherically shaped precipitates whose size differs with alloy composition. The largest precipitates occur in the Au20-Cu80 alloy and range in size from submicrometer up to 2 μm in diameter. Precipitates are observed using light microscopy, electron microscopy, and secondary ion mass spectrometry (SIMS). SIMS has demonstrated that the precipitates are present within all the SRM 482 wires that contain copper. Only the pure gold wire is precipitate free. Initial results from the analysis of the Au20-Cu80 alloy indicate that the percentage of precipitates is less than 1 % by area. Electron probe microanalysis (EPMA) of large (2 μm) precipitates in this same alloy indicates that precipitates are detectable by EPMA and that their composition differs significantly from the certified alloy composition. The small size and low percentage of these oxide precipitates minimizes the impact that they have upon the intended use of this standard for electron probe microanalysis. Heterogeneity caused by these oxide precipitates may however preclude the use of this standard for automated EPMA analyses and other microanalysis techniques. PMID:27446759
Certification of biological candidates reference materials by neutron activation analysis
NASA Astrophysics Data System (ADS)
Kabanov, Denis V.; Nesterova, Yulia V.; Merkulov, Viktor G.
2018-03-01
The paper gives the results of interlaboratory certification of new biological candidate reference materials by neutron activation analysis recommended by the Institute of Nuclear Chemistry and Technology (Warsaw, Poland). The correctness and accuracy of the applied method was statistically estimated for the determination of trace elements in candidate reference materials. The procedure of irradiation in the reactor thermal fuel assembly without formation of fast neutrons was carried out. It excluded formation of interfering isotopes leading to false results. The concentration of more than 20 elements (e.g., Ba, Br, Ca, Co, Ce, Cr, Cs, Eu, Fe, Hf, La, Lu, Rb, Sb, Sc, Ta, Th, Tb, Yb, U, Zn) in candidate references of tobacco leaves and bottom sediment compared to certified reference materials were determined. It was shown that the average error of the applied method did not exceed 10%.
Lenters-Westra, Erna; English, Emma
2017-08-28
As a reference laboratory for HbA1c, it is essential to have accurate and precise HbA1c methods covering a range of measurement principles. We report an evaluation of the Abbott Enzymatic (Architect c4000), Roche Gen.3 HbA1c (Cobas c513) and Tosoh G11 using different quality targets. The effect of hemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP) reference systems was assessed using certified evaluation protocols. Each of the evaluated HbA1c methods had CVs <3% in SI units and <2% in NGSP units at 46 mmol/mol (6.4%) and 72 mmol/mol (8.7%) and passed the NGSP criteria when compared with six secondary reference measurement procedures (SRMPs). Sigma was 8.6 for Abbott Enzymatic, 3.3 for Roche Cobas c513 and 6.9 for Tosoh G11. No clinically significant interference was detected for the common Hb variants for the three methods. All three methods performed well and are suitable for clinical application in the analysis of HbA1c. Partly based on the result of this study, the Abbott Enzymatic method on the Architect c4000 and the Roche Gen.3 HbA1c on the Cobas c513 are now official, certified IFCC and NGSP SRMPs in the IFCC and NGSP networks. Sigma metrics quality criteria presented in a graph distinguish between good and excellent performance.
Khan, Sumaira; Soylak, Mustafa; Kazi, Tasneem Gul
2013-12-01
The current work develops a new green methodology for the separation/preconcentration of cadmium ions (Cd(2+)) using room temperature ionic liquid-dispersive liquid phase microextraction (RTIL-DLME) prior to analysis by flame atomic absorption spectrometry with microsample introduction system. Room temperature ionic liquids (RTIL) are considered "Green Solvents" for their thermally stable and non-volatile properties, here 1-butyl-3-methylimidazolium hexafluorophosphate [C4mim][PF6] was used as an extractant. The preconcentration of Cd(2+) in different waters and acid digested scalp hair samples were complexed with 1-(2-pyridylazo)-2-naphthol and extracted into the fine drops of RTILs. Some significant factors influencing the extraction efficiency of Cd(2+) and its subsequent determination, including pH, amount of ligand, volume of RTIL, dispersant solvent, sample volume, temperature, and incubation time were investigated in detail. The limit of detection and the enhancement factor under the optimal conditions were 0.05 μg/L and 50, respectively. The relative standard deviation of 100 μg/L Cd(2+) was 4.3 %. The validity of the proposed method was checked by determining Cd(2+) in certified reference material (TM-25.3 fortified water). The sufficient recovery (>98 %) of Cd(2+) with the certified value. The mean concentrations of Cd in lake water 13.2, waste water 15.7 and hair sample 16.8 μg/L, respectively and the developed method was applied satisfactorily to the preconcentration and determination of Cd(2+) in real samples.
Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem
2016-04-01
A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples. Copyright © 2015 Elsevier Inc. All rights reserved.
Tian, Hua; Hu, Zheng; He, Qun; Liu, Xueliang; Zhang, Li; Chang, Xijun
2012-07-01
Two solid-phase adsorbents (phase I and phase II) were synthesized successfully that o-Anisic acid derivatives were evenly functionalized on the surface of activated carbon. It was certified that the two adsorbents were applied to preconcentrate and separate trace levels of Pb(II) and Fe(III) from natural liquid samples with satisfactory results. It can be found that the adsorption capacity of the ions adsorbed on phase I and phase II was 48.3 and 85.7 mg g(-1) for Pb(II), 39.5 and 72.5 mg g(-1) for Fe(III), respectively. The detection limit (3σ) of the method separated on phase I and phase II was 0.12 and 0.09 ng mL(-1) for Pb(II), 0.23 and 0.17 ng mL(-1) for Fe(III), respectively. The relative standard deviation (R.S.D.) of the method was lower than 3.0%. The adsorption and desorption property of two kinds of adsorbents was comparatively studied, respectively. The adsorption selectivity of heavy metal ions at certain pH, the adsorption kinetics, the condition of complete elution, the effect of coexisting ions, the adsorption capacity and adsorption isotherm modes were examined. Based on the experimental datum determined by inductively coupled plasma optical emission spectrometry (ICP-OES), it was certified that the adsorption on the surface of adsorbents was in strict accordance with the monolayer adsorption principle. The structural features of series of multidentate ligand modified on adsorption matrix had been obtained. These conclusions can provide reference for synthesizing an efficient adsorbent which is specific to remove a particular kind of contaminant. Copyright © 2012 Elsevier B.V. All rights reserved.
EPA issues interim final waste minimization guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bergeson, L.L.
1993-08-01
The U.S. Environmental Protection Agency (EPA) has released a new and detailed interim final guidance to assist hazardous waste generators in certifying they have a waste minimization program in place under the Resource Conservation and Recovery Act (RCRA). EPA's guidance identifies the basic elements of a waste minimization program in place that, if present, will allow people to certify they have implemented a program to reduce the volume and toxicity of hazardous waste to the extent economically practical. The guidance is directly applicable to generators of 1000 or more kilograms per month of hazardous waste, or large-quantity generators, and tomore » owners and operators of hazardous waste treatment, storage or disposal facilities who manage their own hazardous waste on site. Small-quantity generators that generate more than 100 kilograms, but less than 1,000 kilograms, per month of hazardous waste are not subject to the same program in place certification requirement. Rather, they must certify on their manifests that they have made a good faith effort to minimize their waste generation.« less
Strategic Behavior in Certifying Green Buildings: An Inquiry of the Non-building Performance Value.
Chiang Hsieh, Lin-Han; Noonan, Douglas
2017-08-01
This study determines the magnitude of the market signaling effect arising from Leadership in Energy and Environmental Design certification for green buildings and explores the mechanisms behind the signaling effect. Previous studies have shown that signaling or marketability plays an important role in the pursuit for Leadership in Energy and Environmental Design and equivalent green-building certification. By analyzing all new construction projects receiving Leadership in Energy and Environmental Design certification from 2000 to 2012 in the US, this study estimates the relative importance of 'green' signaling. This broad perspective using project-level data enables an analysis of some drivers of signaling and the pursuit of marketing benefits. The roles of local competition and market conditions, as well as municipal regulations are examined, especially as they differ between types of building owners (e.g., for-profit firms, governments, nonprofits). The results indicate that the non-building performance value-value captured by Leadership in Energy and Environmental Design signals above and beyond the specific building attributes that Leadership in Energy and Environmental Design certifies-dominates the attainment of Leadership in Energy and Environmental Design scores around certification tier thresholds. Further, strong evidence of spatial clustering of this non-building performance value for some owner types indicates that for-profit owners may be more responsive to local competition than non-profit owners. Local legislative mandates predict greater signaling intensity by government-owned buildings, as expected, but for-profit-owned projects tend to signal less, even after controls for local conditions. The results highlight the importance of local conditions, including peer effects and regulations, in driving non-building performance values across a wide range of green buildings.
14 CFR 158.15 - Project eligibility at PFC levels of $1, $2, or $3.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., ventilation, plumbing, and electrical service), and aircraft fueling facilities next to the gate; (7) A... service airport to low-emission technology certified or verified by the Environmental Protection Agency to... equipment that include low-emission technology or use cleaner burning fuels. (c) An eligible project must be...
EPA is responsible for certifying that DOE’s Waste Isolation Pilot Plant (WIPP) remains in compliance with environmental standards for the disposal of transuranic waste. 40 CFR Part 194 specifies criteria for certification or recertification of WIPP.
76 FR 4612 - Community Trade Adjustment Assistance Program Fiscal Year 2010 Annual Report
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-26
... Pleasant Prairie, Wisconsin to help build the 40,000-square-foot Southeast Wisconsin Innovation Center, which was certified under the U.S. Green Building Council's Leadership in Energy and Environmental... competitiveness; and 6. Grows the ``green economy.'' Description of Each Grant Awarded in FY 2010 The following is...
40 CFR 1068.25 - What information must I give to EPA?
Code of Federal Regulations, 2014 CFR
2014-07-01
...? 1068.25 Section 1068.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... regulations that apply, as authorized by the Clean Air Act. This includes the following things: (a) You must... company to approve and sign any submission of information to us, and to certify that the information is...
40 CFR 1068.25 - What information must I give to EPA?
Code of Federal Regulations, 2012 CFR
2012-07-01
...? 1068.25 Section 1068.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... regulations that apply, as authorized by the Clean Air Act. This includes the following things: (a) You must... company to approve and sign any submission of information to us, and to certify that the information is...
40 CFR 1068.25 - What information must I give to EPA?
Code of Federal Regulations, 2013 CFR
2013-07-01
...? 1068.25 Section 1068.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... regulations that apply, as authorized by the Clean Air Act. This includes the following things: (a) You must... company to approve and sign any submission of information to us, and to certify that the information is...
40 CFR 1048.612 - What is the exemption for delegated final assembly?
Code of Federal Regulations, 2012 CFR
2012-07-01
... final assembly? 1048.612 Section 1048.612 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Compliance Provisions § 1048.612 What is the exemption for delegated final assembly? The provisions of 40 CFR 1068.261 related to delegated final assembly apply for engines certified under this part 1048, with the...
40 CFR 1048.612 - What is the exemption for delegated final assembly?
Code of Federal Regulations, 2010 CFR
2010-07-01
... final assembly? 1048.612 Section 1048.612 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Compliance Provisions § 1048.612 What is the exemption for delegated final assembly? The provisions of 40 CFR 1068.261 related to delegated final assembly apply for engines certified under this part 1048, with the...
40 CFR 1048.612 - What is the exemption for delegated final assembly?
Code of Federal Regulations, 2013 CFR
2013-07-01
... final assembly? 1048.612 Section 1048.612 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Compliance Provisions § 1048.612 What is the exemption for delegated final assembly? The provisions of 40 CFR 1068.261 related to delegated final assembly apply for engines certified under this part 1048, with the...
40 CFR 1048.612 - What is the exemption for delegated final assembly?
Code of Federal Regulations, 2011 CFR
2011-07-01
... final assembly? 1048.612 Section 1048.612 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Compliance Provisions § 1048.612 What is the exemption for delegated final assembly? The provisions of 40 CFR 1068.261 related to delegated final assembly apply for engines certified under this part 1048, with the...
40 CFR 1048.612 - What is the exemption for delegated final assembly?
Code of Federal Regulations, 2014 CFR
2014-07-01
... final assembly? 1048.612 Section 1048.612 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Compliance Provisions § 1048.612 What is the exemption for delegated final assembly? The provisions of 40 CFR 1068.261 related to delegated final assembly apply for engines certified under this part 1048, with the...
Certifying the harvest: developments in NTFP certification
Patrick Mallet
2001-01-01
I coordinate a Certification and Marketing program for Falls Brook Centre, an environmental organization based in New Brunswick. I first got interested in certification issues during my work with an international agroforestry network whose members wanted to highlight the ecological practices inherent in their production system. In my initial research, I found that a...
47 CFR 80.1061 - Special requirements for 406.0-406.1 MHz EPIRB stations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... for a 406.0-406.1 MHz radiobeacon, the radiobeacon must be certified by a test facility recognized by one of the COSPAS-SARSAT Partners that the equipment satisfies the design characteristics associated...). Additionally, the radiobeacon must be subjected to the environmental and operational tests associated with the...
47 CFR 80.1061 - Special requirements for 406.0-406.1 MHz EPIRB stations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... for a 406.0-406.1 MHz radiobeacon, the radiobeacon must be certified by a test facility recognized by one of the COSPAS-SARSAT Partners that the equipment satisfies the design characteristics associated...). Additionally, the radiobeacon must be subjected to the environmental and operational tests associated with the...
47 CFR 80.1061 - Special requirements for 406.0-406.1 MHz EPIRB stations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... for a 406.0-406.1 MHz radiobeacon, the radiobeacon must be certified by a test facility recognized by one of the COSPAS-SARSAT Partners that the equipment satisfies the design characteristics associated...). Additionally, the radiobeacon must be subjected to the environmental and operational tests associated with the...
15 CFR 970.513 - Revision of a license.
Code of Federal Regulations, 2010 CFR
2010-01-01
... ENVIRONMENTAL DATA SERVICE DEEP SEABED MINING REGULATIONS FOR EXPLORATION LICENSES Issuance/Transfer/Terms... application, some details may have to be provided in the future in the form of a revision. In such instances... Administrator as a revision is a major change in one or more of: (1) The bases for certifying the original...
40 CFR 85.510 - Exemption provisions for new and relatively new vehicles/engines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... relatively new vehicles/engines. 85.510 Section 85.510 Protection of Environment ENVIRONMENTAL PROTECTION... relatively new vehicles/engines. (a) You are exempted from the tampering prohibition with respect to new and relatively new vehicles/engines if you certify the conversion system to the emission standards specified in...
Greener Schools, Greater Learning, and the LEED Value
ERIC Educational Resources Information Center
Johnson, Priscilla D.; Kritsonis, William Allan
2010-01-01
Schools certified under the LEED [Leadership in Energy and Environmental Design] certification support educational programs are the beacons to sustain our Earth. Green schools are a mechanism for learning and their existence is pure example for the future of school facility planning. The purpose of this article is to discuss the various approaches…
14 CFR 158.15 - Project eligibility at PFC levels of $1, $2, or $3.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., ventilation, plumbing, and electrical service), and aircraft fueling facilities next to the gate; (7) A... service airport to low-emission technology certified or verified by the Environmental Protection Agency to... equipment that include low-emission technology or use cleaner burning fuels. (c) An eligible project must be...
Non-Certified Environment and Geography Subject Expertise in Chilean Rural Educators
ERIC Educational Resources Information Center
Salinas-Silva, Victor; Arenas-Martija, Andoni; Margalef-García, Leonor
2016-01-01
In this paper, environmental and geographical subject expertise is explored, based on the notion of expertise as rooted both in subject knowledge and knowledge of teaching and as acquired through experience. The research questions that guided this study focused on the importance of understanding how teachers negotiate their assumptions and what…
Peng, Hanyong; Zhang, Nan; He, Man; Chen, Beibei; Hu, Bin
2015-01-01
Speciation analysis of inorganic arsenic, chromium and selenium in environmental waters is of great significance for the monitoring of environmental pollution. In this work, 3-(2-aminoethylamino) propyltrimethoxysilane (AAPTS) functionalized multi-wall carbon nanotubes (MWCNTs) were synthesized and employed as the adsorbent for simultaneous speciation analysis of inorganic arsenic, chromium and selenium in environmental waters by microcolumn solid-phase extraction (SPE)-inductively coupled plasma mass spectrometry (ICP-MS). It was found that As(V), Cr(VI) and Se(VI) could be selectively adsorbed on the microcolumn packed with AAPTS-MWCNTs adsorbent at pH around 2.2, while As(III), Cr(III) and Se(IV) could not be retained at this pH and passed through the microcolumn directly. Total inorganic arsenic, chromium and selenium was determined after the oxidation of As(III), Cr(III) and Se(IV) to As(V), Cr(VI) and Se(VI) with 10.0 μmol L(-1) KMnO4. The assay of As(III), Cr(III) and Se(IV) was based on subtracting As(V), Cr(VI) and Se(VI) from the total As, Cr and Se, respectively. Under the optimized conditions, the detection limits of 15, 38 and 16 ng L(-1) with the relative standard deviations (RSDs) of 7.4, 2.4 and 6.2% (c=1 µg L(-1), n=7) were obtained for As(V), Cr(VI) and Se(VI), respectively. The developed method was validated by analyzing four Certified Reference Materials, rainwater, Yangtze River and East Lake waters. Copyright © 2014 Elsevier B.V. All rights reserved.
2005-01-01
specifically, we show how to write a two-generations collector for a language with mutable ref cells. 1 Introduction As the technology of certifying...how to write a two-generations collector for a language with mutable ref cells. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...stated goals, we make the following contributions: – A language that can seamlessly combine the benefits of traditional intuitionistic references and
Certified In-lined Reference Monitoring on .NET
2006-06-01
Introduction Language -based approaches to computer security have employed two major strategies for enforcing security policies over untrusted programs. • Low...automatically verify IRM’s using a static type-checker. Mobile (MOnitorable BIL with Effects) is an exten- sion of BIL (Baby Intermediate Language ) [15], a...AVAILABILITY STATEMENT Approved for public release; distribution unlimited 13. SUPPLEMENTARY NOTES Proceedings of the 2006 Programming Languages and
ERIC Educational Resources Information Center
Glazerman, Steven; Seif, Elizabeth; Baxter, Gail
2008-01-01
This report examines the career trajectories of those who have successfully completed the Passport to Teaching certification offered by the American Board for Certification of Teacher Excellence (ABCTE) during its first years of existence. To elicit information on the career choices of Passport alumni, Mathematica Policy Research, Inc. (MPR)…
Code of Federal Regulations, 2012 CFR
2012-07-01
... rigorous statistical experimental design and interpretation (Reference 16.4). 14.0Pollution Prevention 14... fluids. 1.4This method has been designed to show positive contamination for 5% of representative crude....1Sample collection bottles/jars—New, pre-cleaned bottles/jars, lot-certified to be free of artifacts...
Code of Federal Regulations, 2013 CFR
2013-07-01
... rigorous statistical experimental design and interpretation (Reference 16.4). 14.0Pollution Prevention 14... fluids. 1.4This method has been designed to show positive contamination for 5% of representative crude....1Sample collection bottles/jars—New, pre-cleaned bottles/jars, lot-certified to be free of artifacts...
Code of Federal Regulations, 2014 CFR
2014-07-01
... rigorous statistical experimental design and interpretation (Reference 16.4). 14.0Pollution Prevention 14... fluids. 1.4This method has been designed to show positive contamination for 5% of representative crude....1Sample collection bottles/jars—New, pre-cleaned bottles/jars, lot-certified to be free of artifacts...
Code of Federal Regulations, 2011 CFR
2011-07-01
... rigorous statistical experimental design and interpretation (Reference 16.4). 14.0Pollution Prevention 14... oil contamination in drilling fluids. 1.4This method has been designed to show positive contamination....1Sample collection bottles/jars—New, pre-cleaned bottles/jars, lot-certified to be free of artifacts...
Miyashita, Shin-ichi; Inagaki, Kazumi; Narukawa, Tomohiro; Zhu, Yanbei; Kuroiwa, Takayoshi; Hioki, Akiharu; Chiba, Koichi
2012-01-01
A certified reference material (CRM) for trace cadmium and other elements in brown rice flour was developed at the National Metrology Institute of Japan (NMIJ). The CRM was provided as a dry powder after drying and frozen pulverization of fresh brown rice obtained from a Japanese domestic market. Characterization of the property value for each element was carried out exclusively by NMIJ with at least two independent analytical methods, including inductively coupled plasma mass spectrometry (ICP-MS), ICP high-resolution mass spectrometry, isotope-dilution ICP-MS, ICP optical emission spectrometry, and graphite-furnace atomic-absorption spectrometry. Property values were provided for six elements (Mn, Fe, Cu, Zn, As, and Cd). The concentration range of the property values was from 0.280 mg kg(-1) of As to 31.8 mg kg(-1) of Zn. The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the homogeneity, characterization, difference among analytical methods, dry-mass correction factor, and calibration standard. The range of the relative combined standard uncertainties was from 1.1% of Zn to 1.6% of As.
Helmeczi, Erick; Wang, Yong; Brindle, Ian D
2016-11-01
Short-wavelength infrared radiation has been successfully applied to accelerate the acid digestion of refractory rare-earth ore samples. Determinations were achieved with microwave plasma-atomic emission spectrometry (MP-AES) and dynamic reaction cell - inductively coupled plasma-mass spectrometry (DRC-ICP-MS). The digestion method developed was able to tackle high iron-oxide and silicate matrices using only phosphoric acid in a time frame of only 8min, and did not require perchloric or hydrofluoric acid. Additionally, excellent recoveries and reproducibilities of the rare earth elements, as well as uranium and thorium, were achieved. Digestions of the certified reference materials OREAS-465 and REE-1, with radically different mineralogies, delivered results that mirror those obtained by fusion processes. For the rare-earth CRM OKA-2, whose REE data are provisional, experimental data for the rare-earth elements were generally higher than the provisional values, often exceeding z-values of +2. Determined values for Th and U in this reference material, for which certified values are available, were in excellent agreement. Copyright © 2016 Elsevier B.V. All rights reserved.
A new, high-precision measurement of the X-ray Cu K α spectrum
NASA Astrophysics Data System (ADS)
Mendenhall, Marcus H.; Cline, James P.; Henins, Albert; Hudson, Lawrence T.; Szabo, Csilla I.; Windover, Donald
2016-03-01
One of the primary measurement issues addressed with NIST Standard Reference Materials (SRMs) for powder diffraction is that of line position. SRMs for this purpose are certified with respect to lattice parameter, traceable to the SI through precise measurement of the emission spectrum of the X-ray source. Therefore, accurate characterization of the emission spectrum is critical to a minimization of the error bounds on the certified parameters. The presently accepted sources for the SI traceable characterization of the Cu K α emission spectrum are those of Härtwig, Hölzer et al., published in the 1990s. The structure of the X-ray emission lines of the Cu K α complex has been remeasured on a newly commissioned double-crystal instrument, with six-bounce Si (440) optics, in a manner directly traceable to the SI definition of the meter. In this measurement, the entire region from 8020 eV to 8100 eV has been covered with a highly precise angular scale and well-defined system efficiency, providing accurate wavelengths and relative intensities. This measurement is in modest disagreement with reference values for the wavelength of the Kα1 line, and strong disagreement for the wavelength of the Kα2 line.
Waxin, Marie-France; Knuteson, Sandra L; Bartholomew, Aaron
2017-11-13
Worldwide, ISO 14001 certification for organizations has become the norm, but the Arab world accounts for an insignificant portion of all the certified organizations. There is a dearth of research on environmental management systems (EMS) in Arab and emerging countries and in public organizations. The objectives of this research are to: (1) examine the key drivers and challenges related to implementation of ISO 14001 certified EMS in the United Arab Emirates, an emerging Arab country and (2) compare and contrast these drivers and challenges between private and public organizations. We adopt an explorative, qualitative methodology, using semi-structured interviews with environmental managers in 11 organizations (6 private and 5 public) from different industrial sectors. Drivers of EMS certification were mostly similar between private and public organizations, with some differences. Compliance with regulations and standards, and increasing environmental performance were the main drivers for ISO 14001 certification in both private and public organizations. Commitment to sustainability was more important for public organizations. Cost reduction, competitors, leadership commitment and customers' demands were shared drivers, but more stressed by private organizations. Local community and employees' pressures were reported by private organizations only. The challenges to ISO 14001 implementation were similar for private and public organizations. They were: a lack of qualified human resources, practical challenges associated with implementation, a lack of regulations, a lack of support from management, and high costs. Our findings have implications for managers, academics, consultants, and policy makers in the UAE and other emerging markets.
[Calibration of a room air gas monitor with certified reference gases].
Krueger, W A; Trick, M; Schroeder, T H; Unertl, K E
2003-12-01
Photo-acoustic infrared spectrometry is considered to be the gold standard for on-line measurement of anesthetic waste gas in room air. For maintenance of the precision of the measurements, the manufacturer recommends calibration of the gas monitor monitor every 3-12 months. We investigated whether the use of reference gases with analysis certificate could serve as a feasible alternative to commercial recalibration. We connected a multi-gas monitor type1302 (Bruel & Kjaer, Naerum, Denmark) to compressed air bottles containing reference gases with analysis certificate. Using a T-piece with a flow-meter, we avoided the entry of room air during the calibration phase. Highly purified nitrogen was used for zero calibration. The reference concentrations for desflurane, enflurane, halothane, isoflurane, and sevoflurane ranged from 41.6-51.1 ml/m(3) (ppm) in synthetic air. Since there is an overlap of the infrared absorption spectra of volatile anesthetics with alcohol used in operating rooms, we performed a cross-compensation with iso-propanol (107.0 ppm). A two-point calibration was performed for N(2)O (96.2 and 979.0 ppm), followed by cross-compensation with CO(2). Nafion tubes were used in order to avoid erroneous measurements due to molecular relaxation phenomena. The deviation of the measurement values ranged initially from 0-2.0% and increased to up to 4.9% after 18 months. For N(2)O, the corresponding values were 4.2% and 2.7%, respectively. Thus, our calibration procedure using certified reference gases yielded precise measurements with low deterioration over 18 months. It seems to be advantageous that the precision can be determined whenever deemed necessary. This allows for an individual decision, when the gas monitor needs to be calibrated again. The costs for reference gases and working time as well as logistic aspects such as storage and expiration dates must be individually balanced against the costs for commercial recalibration.
Rhoderick, George C; Yen, James H
2006-05-01
Primary gravimetric gas cylinder standards containing 30 volatile organic compounds (VOCs) in nitrogen were prepared using a procedure previously developed to prepare gas mixture cylinder standards of VOCs at the 5 nmol/mol level. This set of primary standards was intercompared to existing gas cylinder standards, containing as many as 19 of the 30 volatile organics present in these new primaries, using gas chromatography with a hydrogen flame ionization detector coupled with cryogenic preconcentration. The linear regression analysis showed excellent agreement among the standards for each compound. Similar mixtures containing many of these compounds in treated aluminum gas cylinders have been evaluated over time and have shown stability for as much as 10 years. The development of these 30-component primary standards led to the preparation and certification of a reissue of Standard Reference Material (SRM) 1804 at the nominal amount-of-substance fraction of 5 nmol/mol for each analyte. A lot of 20 cylinders containing the mixture was prepared at NIST following previously demonstrated protocols for preparation of the cylinders. Each cylinder was analyzed against one cylinder from the lot, designated as the "lot standard," for each of the 30 compounds. As a result of the uncertainty analysis, the data showed that rather than declaring the lot homogeneous with a much higher uncertainty, each cylinder could be individually certified. The expanded uncertainty limits ranged from 1.5 to 10% for 28 of the 30 analytes, with two of the analytes having uncertainties as high as 19% in those SRM cylinders certified. Due to stability issues and some high uncertainties for a few analytes in 2 of the samples, 18 of the 20 candidate SRM samples were certified. These volatile organic gas mixtures represent the most complex gas SRMs developed at NIST.
NASA Astrophysics Data System (ADS)
Matusiewicz, Henryk; Ślachciński, Mariusz
2017-07-01
A miniaturized optical emission spectrometer (OES) with capacitively coupled argon microwave microplasma (μCMP) as and excitation source and chemical vapor generation (CVG) for sample introduction was constructed for the determination of trace Hg, As, Sb and Se. The applied method enabled simultaneous determination of hydride-forming elements (As, Sb, Se) and volatile Hg. Mercury cold vapor and the hydride volatile species of As, Sb and Se were generated when standard or sample solutions were separated from the liquid phase for transport to the capacitively coupled microwave microplasma and detection of their atomic emission. A univariate approach and the simplex optimization procedure were used to achieve optimized conditions and derive analytical figures of merit. The experimental concentration detection limits (LODs) for simultaneous determination, calculated as the concentration giving a signal equal to three times of the standard deviation of the blank (LOD, 3σblank criterion, peak height) were 3.0, 1.4, 1.5 and 3.8 ng mL- 1 for Hg, As, Sb and Se, respectively. The method was validated by the analysis of three Certified Reference Materials (NIST 2711, NRCC DOLT-2, NIST 1643e) of different matrix composition and by the standard addition technique. The method offers relatively good precision (RSD ranged from 5% to 8%) for microsampling (200 μL) analysis. The measured of contents of elements in certified reference materials were in good agreement with the certified values (Hg 1.99-6.25 μg g- 1, As 16.6-105 μg g- 1, Sb 19.4-56.88 μg g- 1, Se 1.52-11.68 μg g- 1), according to the Student t-test, for a confidence level of 95%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willie, S.
1998-11-01
The report summarizes the results of the Twelfth Round Intercomparison for Trace Metals in Marine Sediments and Biological Tissues under the directive of the NOAA National Status and Trends Program. A total of forty-four participants were included in the exercise, including NOAA, USEPA, state, Austrailian, Canadian, Mexican and Argentinean laboratories. Two samples were sent by NRC to each participant, a marine sediment collected on the east coast of Canada and a freeze-dried mussel tissue. Laboratories were also asked to analyze two certified reference materials (CRMs) MESS-2 and CRM 2976. The elements to be determined were Al, Cr, Fe, Ni, Cu,more » Zn, As, Se, Ag, Cd, Sn, Hg, and Pb for both matrices, plus Be, Si, Mn, Sb, and Tl for the sediments. An accepted mean and confidence interval was calculated for each analyte in the two unknown samples, laboratory biases were identified and an overall rating of superior, good, fair or others were assigned to each laboratory.« less
NASA Astrophysics Data System (ADS)
Takatsuka, Toshiko; Hirata, Kouichi; Kobayashi, Yoshinori; Kuroiwa, Takayoshi; Miura, Tsutomu; Matsue, Hideaki
2008-11-01
Certified reference materials (CRMs) of shallow arsenic implants in silicon are now under development at the National Metrology Institute of Japan (NMIJ). The amount of ion-implanted arsenic atoms is quantified by Instrumental Neutron Activation Analysis (INAA) using research reactor JRR-3 in Japan Atomic Energy Agency (JAEA). It is found that this method can evaluate arsenic amounts of 1015 atoms/cm2 with small uncertainties, and is adaptable to shallower dopants. The estimated uncertainties can satisfy the industrial demands for reference materials to calibrate the implanted dose of arsenic at shallow junctions.
Krata, Agnieszka; Vassileva, Emilia; Bulska, Ewa
2016-11-01
The analytical procedures for reference measurements of the total Hg and methyl mercury (MeHg) mass fractions at various concentration levels in marine biota samples, candidates for certified reference materials (oyster and clam Gafrarium tumidum), were evaluated. Two modes of application of isotope dilution inductively coupled plasma mass spectrometry method (ID ICP-MS), namely direct isotope dilution and species-specific isotope dilution analysis with the use of two different quantification mass spectrometry techniques were compared. The entire ID ICP-MS measurement procedure was described by mathematical modelling and the combined uncertainty of measurement results was estimated. All factors influencing the final results as well as isotopic equilibrium were systematically investigated. This included the procedural blank, the moisture content in the biota samples and all factors affecting the blend ratio measurements (instrumental background, spectral interferences, dead time and mass discrimination effects as well as the repeatability of measured isotopic ratios). Modelling of the entire measurement procedures and the use of appropriate certified reference materials enable to assure the traceability of obtained values to the International System of Units (SI): the mole or the kilogram. The total mass fraction of mercury in oyster and clam biota samples, after correction for moisture contents, was found to be: 21.1 (1.1) 10(-9) kg kg(-1) (U =5.1% relative, k=2) and 390.0 (9.4) 10(-9) kg kg(-1) (U=2.4% relative, k=2), respectively. For the determination of mercury being present as methyl mercury, the non-chromatographic separation on anion-exchange resin AG1-X8 of the blended samples was applied. The content of MeHg (as Hg) in oyster sample was found: 4.81 (24) 10(-9)kgkg(-1) (U=5.0%, k=2) and 4.84 (21) 10(-9)kgkg(-1) (U=4.3%, k=2) with the use of quadrupole (ICP QMS) or sector field (ICP SFMS) inductively coupled plasma mass spectrometers, respectively. In the case of clam sample, the concentration of MeHg (as Hg) was found to be: 61.0 (2.3) 10(-)(9)kgkg(-1) (U=3.8%, k=2) and 61.3 (2.2) 10(-)(9)kgkg(-1) (U=3.6%, k=2), respectively. The mass fractions for total Hg and MeHg determined in this study were used as a contribution of the International Atomic Energy Agency (IAEA) Environment Laboratories in the characterisation of the IAEA 461 and IAEA 470 certified reference materials. The obtained good agreement with the reference values further validated the methods developed in this study. Copyright © 2016 Elsevier B.V. All rights reserved.
Reference Materials: Significance, General Requirements, and Demand.
Kiełbasa, Anna; Gadzała-Kopciuch, Renata; Buszewski, Bogusław
2016-05-03
Reference materials play an important part in the quality control of measurements. Rapid development of such new scientific disciplines as proteomics, metabolomics, and genomics also necessitates development of new reference materials. This is a great challenge due to the complexity of the production of new reference materials and difficulties associated with achieving their homogeneity and stability. CRMs of tissue are of particular importance. They can be counted among the matrices that are most complex and time consuming in preparation. Tissue is the place of transformation and accumulation of many substances (e.g., metabolites, which are intermediate or end products resulting from metabolic processes). Trace amounts of many substances in tissues must be determined with adequate precision and accuracy. To meet the needs stemming from research and from problems and challenges faced by chemists, analysts, and toxicologists, the number of certified reference materials should be continuously increased.
Methods for the preparation and analysis of solids and suspended solids for total mercury
Olund, Shane D.; DeWild, John F.; Olson, Mark L.; Tate, Michael T.
2004-01-01
The methods documented in this report are utilized by the Wisconsin District Mercury Lab for analysis of total mercury in solids (soils and sediments) and suspended solids (isolated on filters). Separate procedures are required for the different sample types. For solids, samples are prepared by room-temperature acid digestion and oxidation with aqua regia. The samples are brought up to volume with a 5 percent bromine monochloride solution to ensure complete oxidation and heated at 50?C in an oven overnight. Samples are then analyzed with an automated flow injection system incorporating a cold vapor atomic fluorescence spectrometer. A method detection limit of 0.3 ng of mercury per digestion bomb was established using multiple analyses of an environmental sample. Based on the range of masses processed, the minimum sample reporting limit varies from 0.6 ng/g to 6 ng/g. Suspended solids samples are oxidized with a 5 percent bromine monochloride solution and held at 50?C in an oven for 5 days. The samples are then analyzed with an automated flow injection system incorporating a cold vapor atomic fluorescence spectrometer. Using a certified reference material as a surrogate for an environmental sample, a method detection limit of 0.059 ng of mercury per filter was established. The minimum sample reporting limit varies from 0.059 ng/L to 1.18 ng/L, depending on the volume of water filtered.
Roles of chemical metrology in electronics industry and associated environment in Korea: a tutorial.
Kang, Namgoo; Joong Kim, Kyung; Seog Kim, Jin; Hae Lee, Joung
2015-03-01
Chemical metrology is gaining importance in electronics industry that manufactures semiconductors, electronic displays, and microelectronics. Extensive and growing needs from this industry have raised the significance of accurate measurements of the amount of substances and material properties. For the first time, this paper presents information on how chemical metrology is being applied to meet a variety of needs in the aspects of quality control of electronics products and environmental regulations closely associated with electronics industry. For a better understanding of the roles of the chemical metrology within electronics industry, the recent research activities and results in chemical metrology are presented using typical examples in Korea where electronic industry is leading a national economy. Particular attention is paid to the applications of chemical metrology for advancing emerging electronics technology developments. Such examples are a novel technique for the accurate quantification of gas composition at nano-liter levels within a MEMS package, the surface chemical analysis of a semiconductor device. Typical metrological tools are also presented for the development of certified reference materials for fluorinated greenhouse gases and proficiency testing schemes for heavy metals and chlorinated toxic gas in order to cope properly with environmental issues within electronics industry. In addition, a recent technique is presented for the accurate measurement of the destruction and removal efficiency of a typical greenhouse gas scrubber. Copyright © 2014 Elsevier B.V. All rights reserved.
Cardellicchio, Nicola; Di Leo, Antonella; Giandomenico, Santina; Santoro, Stefania
2006-01-01
Optimization of acid digestion method for mercury determination in marine biological samples (dolphin liver, fish and mussel tissues) using a closed vessel microwave sample preparation is presented. Five digestion procedures with different acid mixtures were investigated: the best results were obtained when the microwave-assisted digestion was based on sample dissolution with HNO3-H2SO4-K2Cr2O7 mixture. A comparison between microwave digestion and conventional reflux digestion shows there are considerable losses of mercury in the open digestion system. The microwave digestion method has been tested satisfactorily using two certified reference materials. Analytical results show a good agreement with certified values. The microwave digestion proved to be a reliable and rapid method for decomposition of biological samples in mercury determination.
A novel method for the activity measurement of large-area beta reference sources.
Stanga, D; De Felice, P; Keightley, J; Capogni, M; Ioan, M R
2016-03-01
A novel method has been developed for the activity measurement of large-area beta reference sources. It makes use of two emission rate measurements and is based on the weak dependence between the source activity and the activity distribution for a given value of transmission coefficient. The method was checked experimentally by measuring the activity of two ((60)Co and (137)Cs) large-area reference sources constructed from anodized aluminum foils. Measurement results were compared with the activity values measured by gamma spectrometry. For each source, they agree within one standard uncertainty and also agree within the same limits with the certified values of the source activity. Copyright © 2015 Elsevier Ltd. All rights reserved.
NREL's Research Support Facility Certified LEED® Platinum | News | NREL
to sustainable building design and construction. At 222,000 square-feet, the RSF is a model for sustainable, high performance building design that leverages the best in energy efficiency and environmental energy use in commercial buildings that were incorporated in the design of the RSF. NREL researchers are
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
... revisions to Sec. 75.4(e)(1), oxygen (O 2 ) and moisture monitoring systems were inadvertently [[Page 50131... passed in order for readings on the certified high scale to be reported as quality-assured. This was not..., disproportionately high and adverse human health or environmental effects of their programs, policies, and activities...
Fiscal Year 2015 Site Sustainability Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Witt, Monica Rene
Los Alamos National Laboratory is taking action to operate as a living laboratory for sustainable solutions in buildings, climate, energy, purchasing, transportation, waste, and water. LANL prepared the fiscal year (FY) 2015 Site Sustainability Plan (SSP) to describe progress towards the goals established in the SSPP. In addition, per the requirements of DOE Order 436.1, Departmental Sustainability, Los Alamos National Laboratory (LANL) uses its International Organization for Standardization (ISO) 14001:2004 certified Environmental Management System (EMS) to establish objectives to improve compliance, reduce environmental impacts, increase operational capacity, and meet long-term sustainability goals. The goals of the 2015 SSP are fullymore » integrated into LANL’s institutional environmental objectives under the EMS and its Long-Term Strategy for Environmental Stewardship & Sustainability (LTSESS).« less
Lowenthal, Mark S; Yen, James; Bunk, David M; Phinney, Karen W
2010-05-01
An isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) measurement procedure was developed to accurately quantify amino acid concentrations in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 2389a-amino acids in 0.1 mol/L hydrochloric acid. Seventeen amino acids were quantified using selected reaction monitoring on a triple quadrupole mass spectrometer. LC-MS/MS results were compared to gravimetric measurements from the preparation of SRM 2389a-a reference material developed at NIST and intended for use in intra-laboratory calibrations and quality control. Quantitative mass spectrometry results and gravimetric values were statistically combined into NIST-certified mass fraction values with associated uncertainty estimates. Coefficients of variation (CV) for the repeatability of the LC-MS/MS measurements among amino acids ranged from 0.33% to 2.7% with an average CV of 1.2%. Average relative expanded uncertainty of the certified values including Types A and B uncertainties was 3.5%. Mean accuracy of the LC-MS/MS measurements with gravimetric preparation values agreed to within |1.1|% for all amino acids. NIST SRM 2389a will be available for characterization of routine methods for amino acid analysis and serves as a standard for higher-order measurement traceability. This is the first time an ID LC-MS/MS methodology has been applied for quantifying amino acids in a NIST SRM material.
NASA Astrophysics Data System (ADS)
Croce, M. P.; Hoover, A. S.; Rabin, M. W.; Bond, E. M.; Wolfsberg, L. E.; Schmidt, D. R.; Ullom, J. N.
2016-08-01
Microcalorimeters with embedded radioisotopes are an emerging category of sensor with advantages over existing methods for isotopic analysis of trace-level nuclear materials. For each nuclear decay, the energy of all decay products captured by the absorber (alpha particles, gamma rays, X-rays, electrons, daughter nuclei, etc.) is measured in one pulse. For alpha-decaying isotopes, this gives a measurement of the total nuclear reaction energy (Q value) and the spectra consist of well-separated, narrow peaks. We have demonstrated a simple mechanical alloying process to create an absorber structure consisting of a gold matrix with small inclusions of a radioactive sample. This absorber structure provides an optimized energy thermalization environment, resulting in high-resolution spectra with minimal tailing. We have applied this process to the analysis of particles collected from the surface of a plutonium metal certified reference material (CRM-126A from New Brunswick Laboratory) and demonstrated isotopic analysis by microcalorimeter Q value spectroscopy. Energy resolution from the Gaussian component of a Bortels function fit was 1.3 keV FWHM at 5244 keV. The collected particles were integrated directly into the detector absorber without any chemical processing. The ^{238}Pu/^{239}Pu and ^{240}Pu/^{239}Pu mass ratios were measured and the results confirmed against the certificate of analysis for the reference material. We also demonstrated inter-element analysis capability by measuring the ^{241}Am/^{239}Pu mass ratio.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-23
...-10 standard is determined by calculating the expected number of days in a year with PM-10... PM-10. See 40 CFR part 50, appendix K. A complete year of air quality data, as referred to in 40 CFR... certified. As noted above, the 24-hour PM-10 standard is attained when the expected number of days per year...
Automated, Certified Program-rewriting for Software Security Enforcement
2012-03-05
VLC ), pages 257-260, Oak Brook, Illinois, Oc- tober 2010. [14] Aditi A. Patwardhan. Security-aware program visualization for analyz- ing in-lined...January 2010. [17] Meera Sridhar and Kevin W. Hamlen. Flexible in-lined reference moni- tor certification: Challenges and future directions. In...pages 55-60, Austin, Texas, January 2011. [18] Bhavani Thuraisingham and Kevin W. Hamlen. Challenges and future directions of software technology