Sample records for eo gas sterilization

  1. Comparison of sterilization of reusable endoscopic biopsy forceps by autoclaving and ethylene oxide gas.

    PubMed

    Yoon, Jai Hoon; Yoon, Byung Chul; Lee, Hang Lak; Lee, Jun Kyu; Kim, Yong-Tae; Lee, Dong Ho; Choi, Il Ju; Lee, Don Haeng; Kim, Dong Hee

    2012-02-01

    Every country has standardized reprocessing guidelines for reducing the risk of microorganism transmission via reusable biopsy forceps. Sterilization is performed either by autoclaving or with the use of ethylene oxide (EO) gas. However, there are no clear standard global recommendations. The aim of this study was to determine whether EO gas or autoclaving is a safer and more effective method for the sterilization of reusable forceps. This was a prospective study conducted at multiple tertiary referral centers. Seventy reusable biopsy forceps that had been reused at least 20 times each were collected from six endoscopy centers. In all, 61 forceps from five centers were sterilized using EO gas, and the nine forceps from the remaining center were placed in an autoclave. We performed real-time polymerase chain reaction (RT-PCR) for Mycobacterium tuberculosis and hepatitis B virus and performed bacterial cultures on the reusable forceps, which were cut into 2- to 3-cm sections. The forceps were also scanned with an electron microscope (EM) to detect surface damage and contamination. Escherichia coli bacteria were cultured from 2 of the 61 (3.3%) reusable biopsy forceps sterilized with EO gas. On EM scanning, abundant debris and tissue materials remained on the cup surfaces of the reused biopsy forceps and on their inner wires. No microorganisms were found on the autoclaved forceps. Sterilization with EO gas may be inadequate because the complicated structure of the forceps may interfere with sterilization. Therefore, for optimum safety, reusable biopsy forceps should be sterilized by autoclaving.

  2. Apparatus Circulates Sterilizing Gas

    NASA Technical Reports Server (NTRS)

    Cross, John H.; Schwarz, Ray P.

    1991-01-01

    Apparatus circulates sterilizing gas containing ethylene oxide and chlorofluorocarbon through laboratory or medical equipment. Confines sterilizing gas, circulating it only through parts to be treated. Consists of two units. One delivers ethylene oxide/chlorofluorocarbon gas mixture and removes gas after treatment. Other warms, humidifies, and circulates gas through equipment to be treated. Process provides reliable sterilization with negligible residual toxicity from ethylene oxide. Particularly suitable for sterilization of interiors of bioreactors, heart/lung machines, dialyzers, or other equipment including complicated tubing.

  3. Evaluation of in vitro serial antibiotic elution from meropenem-impregnated polymethylmethacrylate beads after ethylene oxide gas and autoclave sterilization.

    PubMed

    Báez, L A; Langston, C; Givaruangsawat, S; McLaughlin, R

    2011-01-01

    To determine the elution properties of meropenem and to compare the elutions of meropenem-impregnated polymethylmethacrylate (PMMA) beads without sterilization (P-M-C) to those sterilized with steam (P-M-A) and ethylene oxide gas (P-M-EO). A commercial bead mould was used to produce four groups of beads: one group without antibiotic (negative control), and three groups of meropenem-impregnated beads: P-M-C, P-M-A, and P-M-EO. The beads were placed in a phosphate buffered solution and eluent samples were collected. Concentrations of the antibiotic in eluent samples from the two sterilized groups and the control beads were determined using a microbiological assay at 1, 3, 6 and 12 hours and at 1, 2, 3, 6, 9, 12, 15, 18, 22, 26, and 30 days. The microbiological assay resulted in no zone of inhibition at all time periods for the P-M-A samples and the samples of PMMA without antimicrobial. The meropenem concentration on the eluent remained above 4 mcg/ml for 15 days in the P-M-C group and until day 18 for P-M-EO group. There was no statistical difference in AUC0-∞ (p<0.318), however significance did occur for MRT (p<0.005) when comparing P-M-C and P-M-EO with the later being higher. The meropenem incorporated in the PMMA beads eluted effectively and gradually decreased after the 24 hour peak, but remained above the concentration level of 4 mcg/ml for 15 days in the P-M-C group and until day 18 for P-M-EO group. Ethylene oxide does not adversely affect meropenem's elution from PMMA beads.

  4. Product sterilization. Why industry uses radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sparks, B.J.

    1984-09-01

    Industry uses gamma radiation sterilization because of its superior reliability, safety, and cost savings over the EO fumigation method. EO has many processing variables and is toxic and expensive. The Environmental Protection Agency has recently declared EO to be both mutagenic and carcinogenic. The residual EO in hospital products has been reported to adversely affect hospital workers. Unlike EO fumigation, radiation sterilization imparts no toxic residuals. The coloration and embrittlement problems experienced earlier with some products sterilized by gamma radiation are being overcome with the introduction of new manufacturing materials and lower radiation dosages. Other benefits of radiation sterilization includemore » the option of sterilizing some materials that could not otherwise be sterilized and using new types of packaging to better protect the products and increase shelf-life. The emphasis now being placed on cost containment for health care products will be another significant part of the answer to why industry uses gamma radiation sterilization.« less

  5. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO) to...

  6. Gas plasma sterilization of microorganisms and mechanisms of action

    PubMed Central

    SHINTANI, HIDEHARU; SAKUDO, AKIKAZU; BURKE, PETER; McDONNELL, GERALD

    2010-01-01

    The use of true gas plasmas for the inactivation of microorganisms is an area of dynamic research. Many types of gases are used as a source of plasma, and different plasma production methods have been applied. The antimicrobial mechanisms of oxygen-based gas plasmas may be due to an etching effect on microbial structures, particularly bacterial endospores resulting in shrinkage. By contrast, the definite mechanisms of actions of other gas plasma sources, such as N2, He, Ne, Ar and Xe gases, have not been clearly defined and indeed may be distinct. The speculated mechanisms of these gas plasmas involve the direct attack of metastable (excited molecular), UV and/or VUV to microbial structures, specifically the inner membrane and DNA in the core of bacterial endospores. According to this speculation, sterilized spore figures would remain unchanged. However, these mechanisms remain to be clarified. Future perspectives on the use of gas plasma for sterilization are of interest, as it is possible that appropriate sterility assurance levels can be obtained in parallel with material and functional compatibility. Traditional sterilization methods are often limited in these requirements. Therefore, gas plasma sterilization may prove to be an appropriate alternative sterilization procedure. PMID:22993596

  7. Sterilization of medical devices by ethylene oxide, determination of the dissipation of residues, and use of Green Fluorescent Protein as an indicator of process control.

    PubMed

    Dias, Fábio N; Ishii, Marina; Nogaroto, Sergio L; Piccini, Bruno; Penna, Thereza C V

    2009-11-01

    Ethylene oxide (EO) is used to sterilize Oxygenator and Tubing applied to heart surgery. Residual levels of EO and its derivatives, ethylene chlorohydrin (ECH) and ethylene glycol (EG), may be hazardous to the patients. Therefore, it must be removed by the aeration process. This study aimed to estimate the minimum aeration time for these devices to attain safe limits for use (avoiding excessive aeration time) and to evaluate the Green Fluorescent Protein (GFP) as a biosensor capable of best indicating the distribution and penetration of EO gas throughout the sterilization chamber. Sterilization cycles of 2, 4, and 8 h were monitored by Bacillus atrophaeus ATCC 9372 as a biological indicator (BI) and by the GFP. Residual levels of EO, ECH, and EG were determined by gas chromatography (GC), and the residual dissipation was studied. Safe limits were reached right after the sterilization process for Oxygenator and after 204 h of aeration for Tubing. In the 2 h cycle, the GFP concentration decreased from 4.8 (+/-3.2)% to 7.5 (+/-2.5)%. For the 4 h cycle, the GFP concentration decreased from 17.4 (+/-3.0)% to 21.5 (+/-6.8)%, and in the 8 h cycle, it decreased from 22.5 (+/-3.2)% to 23.9 (+/-3.9)%. This finding showed the potentiality for GFP applications as an EO biosensor.

  8. Ozone Gas as a Benign Sterilization Treatment for PLGA Nanofiber Scaffolds

    PubMed Central

    de Jesus Andreoli Pinto, Terezinha; Bou-Chacra, Nadia Araci; Galante, Raquel; de Araújo, Gabriel Lima Barros; do Nascimento Pedrosa, Tatiana; Maria-Engler, Silvya Stuchi

    2016-01-01

    The use of electrospun nanofibers for tissue engineering and regenerative medicine applications is a growing trend as they provide improved support for cell proliferation and survival due, in part, to their morphology mimicking that of the extracellular matrix. Sterilization is a critical step in the fabrication process of implantable biomaterial scaffolds for clinical use, but many of the existing methods used to date can negatively affect scaffold properties and performance. Poly(lactic-co-glycolic acid) (PLGA) has been widely used as a biodegradable polymer for 3D scaffolds and can be significantly affected by current sterilization techniques. The aim of this study was to investigate pulsed ozone gas as an alternative method for sterilizing PLGA nanofibers. The morphology, mechanical properties, physicochemical properties, and response of cells to PLGA nanofiber scaffolds were assessed following different degrees of ozone gas sterilization. This treatment killed Geobacillus stearothermophilus spores, the most common biological indicator used for validation of sterilization processes. In addition, the method preserved all of the characteristics of nonsterilized PLGA nanofibers at all degrees of sterilization tested. These findings suggest that ozone gas can be applied as an alternative method for sterilizing electrospun PLGA nanofiber scaffolds without detrimental effects. PMID:26757850

  9. Ozone Gas as a Benign Sterilization Treatment for PLGA Nanofiber Scaffolds.

    PubMed

    Rediguieri, Carolina Fracalossi; Pinto, Terezinha de Jesus Andreoli; Bou-Chacra, Nadia Araci; Galante, Raquel; de Araújo, Gabriel Lima Barros; Pedrosa, Tatiana do Nascimento; Maria-Engler, Silvya Stuchi; De Bank, Paul A

    2016-04-01

    The use of electrospun nanofibers for tissue engineering and regenerative medicine applications is a growing trend as they provide improved support for cell proliferation and survival due, in part, to their morphology mimicking that of the extracellular matrix. Sterilization is a critical step in the fabrication process of implantable biomaterial scaffolds for clinical use, but many of the existing methods used to date can negatively affect scaffold properties and performance. Poly(lactic-co-glycolic acid) (PLGA) has been widely used as a biodegradable polymer for 3D scaffolds and can be significantly affected by current sterilization techniques. The aim of this study was to investigate pulsed ozone gas as an alternative method for sterilizing PLGA nanofibers. The morphology, mechanical properties, physicochemical properties, and response of cells to PLGA nanofiber scaffolds were assessed following different degrees of ozone gas sterilization. This treatment killed Geobacillus stearothermophilus spores, the most common biological indicator used for validation of sterilization processes. In addition, the method preserved all of the characteristics of nonsterilized PLGA nanofibers at all degrees of sterilization tested. These findings suggest that ozone gas can be applied as an alternative method for sterilizing electrospun PLGA nanofiber scaffolds without detrimental effects.

  10. Polystyrene Foam EOS as a Function of Porosity and Fill Gas

    NASA Astrophysics Data System (ADS)

    Mulford, Roberta; Swift, Damian

    2009-06-01

    An accurate EOS for polystyrene foam is necessary for analysis of numerous experiments in shock compression, inertial confinement fusion, and astrophysics. Plastic to gas ratios vary between various samples of foam, according to the density and cell-size of the foam. A matrix of compositions has been investigated, allowing prediction of foam response as a function of the plastic-to-air ratio. The EOS code CHEETAH allows participation of the air in the decomposition reaction of the foam, Differences between air-filled, nitrogen-blown, and CO2-blown foams are investigated, to estimate the importance of allowing air to react with plastic products during decomposition. Results differ somewhat from the conventional EOS, which are generated from values for plastic extrapolated to low densities.

  11. Confirmation of the sterilization effect using a high concentration of ozone gas for the bio-clean room.

    PubMed

    Iwamura, Takuji; Nagano, Katsunori; Nogami, Toshihiro; Matsuki, Noritomo; Kosaka, Noriyoshi; Shintani, Hideharu; Katoh, Miyoshi

    2013-01-01

    A high-level aseptic environment must be maintained in bio-cleanrooms used for the manufacture of sterile products. In the past, formaldehyde gas was most commonly used to sterilize bio-cleanrooms, but due to strict residual limitations there has been a need to develop a less toxic alternative choice. The authors have developed a revolutionary new sterilization system using a high concentration of ozone gas and used this system to sterilize an actual bio-cleanroom. This system integrates the ozone gas generator with the air conditioning system by proper control. The design specifications for the system included an ozone gas concentration of 200 ppm or more, relative humidity of 80% or more, and a sterilizing time of 120 min. Blow vents and suction ports were placed to ensure a uniform airflow which would extend through the entire room during ozone gas sterilization. Tests regarding long-term material exposure to ozone gas were conducted when the system was introduced to distinguish usable and unusable materials. In an actually constructed cleanroom, simulations were used to predict the evenness of the diffusion of ozone gas concentration and relative humidity during ozone gas sterilization, and measurements of the actual indoor ozone gas concentration, temperature and relative humidity during sterilization revealed that the ozone concentration and relative humidity needed for sterilization had been achieved generally throughout the entire environment. In addition, the CT value (mg/m(3) (=ppm) × min) , derived by multiplying the ozone gas concentration during ozone gas sterilization by the sterilization time, was equal to or greater than the target value of 24 × 10(3) (ppm·min) . When the results of sterilization in a cleanroom were confirmed using a biological indicator (BI) , negative results were obtained at all measurement points, demonstrating that sterilization was being performed effectively in the actual factory at which the ozone gas sterilization system

  12. Effects of humidity on sterilization of Geobacillus stearothermophilus spores with plasma-excited neutral gas

    NASA Astrophysics Data System (ADS)

    Matsui, Kei; Ikenaga, Noriaki; Sakudo, Noriyuki

    2015-06-01

    We investigate the effects of relative humidity on the sterilization process using a plasma-excited neutral gas that uniformly sterilizes both the space and inner wall of the reactor chamber at atmospheric pressure. Only reactive neutral species such as plasma-excited gas molecules and radicals were separated from the plasma and sent to the reactor chamber for chemical sterilization. The plasma source gas is nitrogen mixed with 0.1% oxygen, and the relative humidity in the source gas is controlled by changing the mixing ratio of water vapor. The relative humidity near the sample in the reactor chamber is controlled by changing the sample temperature. As a result, the relative humidity near the sample should be kept in the range from 60 to 90% for the sterilization of Geobacillus stearothermophilus spores. When the relative humidity in the source gas increases from 30 to 90%, the sterilization effect is enhanced by the same degree.

  13. Investigation of Sterilization Mechanism for Geobacillus stearothermophilus Spores with Plasma-Excited Neutral Gas

    NASA Astrophysics Data System (ADS)

    Matsui, Kei; Ikenaga, Noriaki; Sakudo, Noriyuki

    2015-09-01

    We investigate the mechanism of the sterilization with plasma-excited neutral gas that uniformly sterilizes both the space and inner wall of the reactor chamber at atmospheric pressure. Only reactive neutral species such as plasma-excited gas molecules and radicals are separated from the plasma and sent to the reactor chamber for chemical sterilization. The plasma source gas uses humidified mixture of nitrogen and oxygen. Geobacillus stearothermophilus spores and tyrosine which is amino acid are treated by the plasma-excited neutral gas. Shape change of the treated spore is observed by SEM, and chemical modification of the treated tyrosine is analyzed by HPLC. As a result, the surface of the treated spore shows depression. Hydroxylation and nitration of tyrosine are shown after the treatment. For these reasons, we believe that the sterilization with plasma-excited neutral gas results from the deformation of spore structure due to the chemical modification of amino acid.

  14. A comparative study of ethylene oxide gas, hydrogen peroxide gas plasma, and low-temperature steam formaldehyde sterilization.

    PubMed

    Kanemitsu, Keiji; Imasaka, Takayuki; Ishikawa, Shiho; Kunishima, Hiroyuki; Harigae, Hideo; Ueno, Kumi; Takemura, Hiromu; Hirayama, Yoshihiro; Kaku, Mitsuo

    2005-05-01

    To compare the efficacies of ethylene oxide gas (EOG), hydrogen peroxide gas plasma (PLASMA), and low-temperature steam formaldehyde (LTSF) sterilization methods. The efficacies of EOG, PLASMA, and LTSF sterilization were tested using metal and plastic plates, common medical instruments, and three process challenge devices with narrow lumens. All items were contaminated with Bacillus stearothermophilus spores or used a standard biological indicator. EOG and LTSF demonstrated effective killing of B. stearothermophilus spores, with or without serum, on plates, on instruments, and in process challenge devices. PLASMA failed to adequately sterilize materials on multiple trials in several experiments, including two of three plates, two of three instruments, and all process challenge devices. Our results suggest that PLASMA sterilization may be unsuccessful under certain conditions, particularly when used for items with complex shapes and narrow lumens. Alternatively, LTSF sterilization demonstrates excellent efficacy and is comparable to EOG sterilization. LTSF could potentially act as a substitute if EOG becomes unavailable due to environmental concerns.

  15. Impact of ethylene oxide gas sterilization of duodenoscopes after a carbapenem-resistant Enterobacteriaceae outbreak.

    PubMed

    Naryzhny, Igor; Silas, Dean; Chi, Kenneth

    2016-08-01

    Carbapenem-resistant Enterobacteriaceae (CRE) outbreaks have been implicated at several medical institutions involving gastroenterology laboratories and, specifically, duodenoscopes. Currently, there are no specific guidelines to eradicate or prevent the outbreak of this bacteria. We describe ethylene oxide (ETO) gas sterilizations of duodenoscopes to address this issue. A complete investigation of the gastroenterology laboratory and an evaluation by the Centers for Disease Control and Prevention concluded that no lapses were found in the reprocessing of the equipment. With no deficiencies to address, we began a novel cleaning process using surgical ETO gas sterilizers in addition to standard endoscope reprocessing recommendations and guidelines, all while trying to eradicate the CRE contamination and prevent future recurrences. We also instituted a surveillance system for recurrence of CRE contamination via monthly cultures of the duodenoscopes. Between October 2013 and April 2014, 589 ERCPs were performed with 645 ETO gas sterilizations of 6 duodenoscopes. Given the extra 16 hours needed to sterilize the duodenoscopes, our institution incurred costs resulting from purchasing additional equipment and surveillance cultures. Four duodenoscopes sustained damage during this period; however, this could not be directly attributed to the sterilization process. Furthermore, after an 18-month success period we encountered a positive CRE culture after sterilization, albeit of a different strain than originally detected during the outbreak. The duodenoscope underwent additional ETO gas sterilization, with a negative repeated culture; all potentially exposed individuals screened negative for CRE. Proper use of high-level disinfection alone may not eliminate multidrug-resistant organisms from duodenoscopes. In this single-center study, the addition of ETO sterilization and frequent monitoring with cultures reduced duodenoscope contamination and eliminated clinical infections

  16. Chlorine Dioxide Gas Sterilization under Square-Wave Conditions

    PubMed Central

    Jeng, David K.; Woodworth, Archie G.

    1990-01-01

    Experiments were designed to study chlorine dioxide (CD) gas sterilization under square-wave conditions. By using controlled humidity, gas concentration, and temperature at atmospheric pressure, standard biological indicators (BIs) and spore disks of environmental isolates were exposed to CD gas. The sporicidal activity of CD gas was found to be concentration dependent. Prehumidification enhanced the CD activity. The D values (time required for 90% inactivation) of Bacillus subtilis subsp. niger ATCC 9372 BIs were estimated to be 1.5, 2.5, and 4.2 min when exposed to CD concentrations of 30, 15, and 7 mg/liter, respectively, at 23°C and ambient (20 to 40%) relative humidity (RH). Survivor tailings were observed. Prehumidification of BIs to 70 to 75% RH in an environmental chamber for 30 min resulted in a D value of 1.6 min after exposure to a concentration of 6 to 7 mg of CD per liter at 23°C and eliminated survivor tailing. Prolonging prehumidification at 70 to 75% RH for up to 16 h did not further improve the inactivation rate. Prehumidification by ultrasonic nebulization was found to be more effective than prehumidification in the environmental chamber, improving the D value to 0.55 min at a CD concentration of 6 to 7 mg/liter. Based on the current observations, CD gas is estimated, on a molar concentration basis, to be 1,075 times more potent than ethylene oxide as a sterilant at 30°C. A comparative study showed B. subtilis var. niger BIs were more resistant than other types of BIs and most of the tested bacterial spores of environmental isolates. PMID:16348127

  17. Evaluation of bactericidal effects of low-temperature nitrogen gas plasma towards application to short-time sterilization.

    PubMed

    Kawamura, Kumiko; Sakuma, Ayaka; Nakamura, Yuka; Oguri, Tomoko; Sato, Natsumi; Kido, Nobuo

    2012-07-01

    To develop a novel low-temperature plasma sterilizer using pure N(2) gas as a plasma source, we evaluated bactericidal ability of a prototype apparatus provided by NGK Insulators. After determination of the sterilizing conditions without the cold spots, the D value of the BI of Geobacillus stearothermophilus endospores on the filter paper was determined as 1.9 min. However, the inactivation efficiency of BI carrying the same endospores on SUS varied to some extent, suggesting that the bactericidal effect might vary by materials of sterilized instruments. Staphylococcus aureus and Escherichia coli were also exposed to the N(2) gas plasma and confirmed to be inactivated within 30 min. Through the evaluation of bactericidal efficiency in a sterilization bag, we concluded that the UV photons in the plasma and the high-voltage pulse to generate the gas plasma were not concerned with the bactericidal effect of the N(2) gas plasma. Bactericidal effect might be exhibited by activated nitrogen atoms or molecular radicals. © 2012 The Societies and Blackwell Publishing Asia Pty Ltd.

  18. Identification and quantification of ethylene oxide in sterilized medical devices using multiple headspace GC/MS measurement.

    PubMed

    Gimeno, Pascal; Auguste, Marie-Laure; Handlos, Vagn; Nielsen, Anne Mette; Schmidt, Stephan; Lassu, Nelly; Vogel, Martin; Fischer, Antonius; Brenier, Charlotte; Duperray, Françoise

    2018-05-22

    This manuscript, based on the ISO 10993-7 approach, describes a multiple HS-GC measurement of residual EO present in sterilized plastic samples. The quantification of EO is done, according to the ISO standard, by addition of EO amounts extracted for each repeated extraction. During the method development, the specificity of the detection of EO regarding acetaldehyde (structural isomer of EO) which may be formed from EO has been ensured and different tests were performed to check a possible influence of the sample preparation. Assays to maximize EO extraction were performed for different materials (Cyclo-olefine Copolymer (COC), Cyclo-olefine Polymer (COP), Silicon, Polyurethane (PUR)) changing extraction temperatures and times for the headspace and the pre-thermal treatment. Results highlight that depending on the material, EO can be more or less retained and thus thermal extraction conditions to maximize the amount of extractible EO from plastics may change accordingly. For COC syringes a validation according to ICH guidelines and an inter-laboratories study were performed. The method has been used for a market survey of EO sterilized medical devices, results obtained are reported in this manuscript. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Limited Range Sesame EOS for Ta

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greeff, Carl William; Crockett, Scott; Rudin, Sven Peter

    2017-03-30

    A new Sesame EOS table for Ta has been released for testing. It is a limited range table covering T ≤ 26, 000 K and ρ ≤ 37.53 g/cc. The EOS is based on earlier analysis using DFT phonon calculations to infer the cold pressure from the Hugoniot. The cold curve has been extended into compression using new DFT calculations. The present EOS covers expansion into the gas phase. It is a multi-phase EOS with distinct liquid and solid phases. A cold shear modulus table (431) is included. This is based on an analytic interpolation of DFT calculations.

  20. Effects of repeated gas sterilization on closure rates of ameroid ring constrictors in vitro.

    PubMed

    Kimberlin, William W; Wardlaw, Jennifer L; Madsen, Richard W

    2016-01-01

    To determine the effect of repeated gas sterilization on rate of closure of ameroid ring constrictors in vitro. Twenty-four 3.5-mm ameroid ring constrictors. Ameroid ring constrictors were allocated to 1 of 4 treatment groups (6/group) to undergo gas sterilization 0, 1, 5, or 10 times. After sterilization, constrictors were incubated in canine plasma at a protein concentration of 3 g/dL for 27 days. A digital camera was used to obtain images of the constrictors prior to and at various points during incubation, and lumen diameter was measured. Mean ± SD percentage of lumen closure for all groups of ameroid ring constrictors combined was 85.2 ± 1.6% at day 0 (prior to plasma incubation) and 95.4 ± 0.8% at day 27. Mean lumen area was 3.64 ± 0.43 mm(2) (95% confidence interval, 2.67 to 4.77 mm(2)) at day 0 and 1.32 ± 0.25 mm(2) (95% confidence interval, 0.76 to 2.04 mm(2)) at day 27. None of the ameroid ring constrictors had closed completely by day 27. Overall closure rates for ameroid ring constrictors appeared to be unaffected by repeated gas sterilization up to 10 times. Findings suggested that veterinary surgeons can resterilize ameroid ring constrictors up to 10 times with confidence that ring properties would remain suitable for clinical use.

  1. System for sterilizing objects. [cleaning space vehicle systems

    NASA Technical Reports Server (NTRS)

    Bryan, C. J.; Wright, E. E., Jr.; Moyers, C. V. (Inventor)

    1981-01-01

    A system for producing a stream of humidified sterilizing gas for sterilizing objects such as the water systems of space vehicles and the like includes a source of sterilant gas which is fed to a mixing chamber which has inlet and outlet ports. The level of the water only partially fills the mixing chamber so as to provide an empty space adjacent the top of the chamber. A heater is provided for heating the water in the chamber so as to produce a humidified atmosphere. The sterilant gas is fed through an arcuate shaped tubular member connected to the inlet port of the mixing chamber for producing a vortex type of flow of sterilant gas into the chamber for humidification. A tubular member extends from the mixing chamber for supplying the humidified sterilant gas to the object for being sterilized. Scrubbers are provided for removing the sterilant gas after use.

  2. Sterilization of silicone-based hydrogels for biomedical application using ozone gas: Comparison with conventional techniques.

    PubMed

    Galante, Raquel; Ghisleni, Daniela; Paradiso, Patrizia; Alves, Vitor D; Pinto, Terezinha J A; Colaço, Rogério; Serro, Ana Paula

    2017-09-01

    Sterilization of hydrogels is challenging due to their often reported sensitivity to conventional methods involving heat or radiation. Although aseptic manufacturing is a possibility, terminal sterilization is safer in biological terms, leading to a higher overall efficiency, and thus should be used whenever it is possible. The main goal of this work was to study the applicability of an innovative ozone gas terminal sterilization method for silicone-based hydrogels and compare its efficacy and effects with those of traditional sterilization methods: steam heat and gamma irradiation. Ozone gas sterilization is a method with potential interest since it is reported as a low cost green method, does not leave toxic residues and can be applied to thermosensitive materials. A hydrogel intended for ophthalmological applications, based on tris(trimethylsiloxy)silyl] propyl methacrylate, was prepared and extensively characterized before and after the sterilization procedures. Alterations regarding transparency, swelling, wettability, ionic permeability, friction coefficient, mechanical properties, topography and morphology and chemical composition were monitored. Efficacy of the ozonation was accessed by performing controlled contaminations and sterility tests. In vitro cytotoxicity testes were also performed. The results show that ozonation may be applied to sterilize the studied material. A treatment with 8 pulses allowed sterilizing the material with bioburdens≤10 3 CFU/mL, preserving all the studied properties within the required known values for contact lenses materials. However, a higher exposure (10 pulses) led to some degradation of the material and induced mild cytotoxicity. Steam heat sterilization led to an increase of swelling capacity and a decrease of the water contact angle. Regarding gamma irradiation, the increase of irradiation dose led to an increase of the friction coefficient. The higher dose (25kGy) originated surface degradation and affected the

  3. Effects of additional vapors on sterilization of microorganism spores with plasma-excited neutral gas

    NASA Astrophysics Data System (ADS)

    Matsui, Kei; Ikenaga, Noriaki; Sakudo, Noriyuki

    2015-01-01

    Some fundamental experiments are carried out in order to develop a plasma process that will uniformly sterilize both the space and inner wall of the reactor chamber at atmospheric pressure. Air, oxygen, argon, and nitrogen are each used as the plasma source gas to which mixed vapors of water and ethanol at different ratios are added. The reactor chamber is remotely located from the plasma area and a metal mesh for eliminating charged particles is installed between them. Thus, only reactive neutral particles such as plasma-excited gas molecules and radicals are utilized. As a result, adding vapors to the source gas markedly enhances the sterilization effect. In particular, air with water and/or ethanol vapor and oxygen with ethanol vapor show more than 6-log reduction for Geobacillus stearothermophilus spores.

  4. The relative safety of gamma-ray, autoclave, and ethylene oxide gas sterilization of thermosetting polyurethane.

    PubMed

    Shintani, H

    1995-01-01

    Sterilization of polyurethane (PU) produces 4,4'-methylenedianiline (MDA), a known carcinogen, and various other compounds. The relationships of the components of PU to the formation of these compounds by sterilization were studied. Specimens of PU fabricated from different combinations of isocyanates and polyols were obtained from dialyzers. The molecular weight of the particular polyol was found to influence the production of MDA by sterilization. Sterilization also produced many unidentified compounds. MDA production was not always associated with the production of the other compounds. Compared with gamma-ray irradiation and ethylene oxide gas (EOG) sterilization, autoclave sterilization eluted more hydrophilic compounds. This phenomenon was significant for PUs produced from smaller-molecular-weight polyols. The combination of autoclave sterilization and a PU produced from a larger-molecular-weight polyol is recommended to minimize the production of potentially toxic compounds. Of the techniques studied, EOG sterilization produced the least amounts of MDA and the other compounds, but the residue of EOG is itself problematic. The risk posed by the amounts of MDA extracted was not significant, but the biological safety of the other compounds remains to be determined.

  5. Characteristics of surface-wave plasma with air-simulated N2 O2 gas mixture for low-temperature sterilization

    NASA Astrophysics Data System (ADS)

    Xu, L.; Nonaka, H.; Zhou, H. Y.; Ogino, A.; Nagata, T.; Koide, Y.; Nanko, S.; Kurawaki, I.; Nagatsu, M.

    2007-02-01

    Sterilization experiments using low-pressure air discharge plasma sustained by the 2.45 GHz surface-wave have been carried out. Geobacillus stearothermoplilus spores having a population of 3.0 × 106 were sterilized for only 3 min using air-simulated N2-O2 mixture gas discharge plasma, faster than the cases of pure O2 or pure N2 discharge plasmas. From the SEM analysis of plasma-irradiated spores and optical emission spectroscopy measurements of the plasmas, it has been found that the possible sterilization mechanisms of air-simulated plasma are the chemical etching effect due to the oxygen radicals and UV emission from the N2 molecules and NO radicals in the wavelength range 200-400 nm. Experiment suggested that UV emission in the wavelength range less than 200 nm might not be significant in the sterilization. The UV intensity at 237.0 nm originated from the NO γ system (A 2Σ+ → X 2Π) in N2-O2 plasma as a function of the O2 percentage added to N2-O2 mixture gas has been investigated. It achieved its maximum value when the O2 percentage was roughly 10-20%. This result suggests that air can be used as a discharge gas for sterilization, and indeed we have confirmed a rapid sterilization with the actual air discharge at a sample temperature of less than 65 °C.

  6. Plasma Sterilization Technology for Spacecraft Applications

    NASA Technical Reports Server (NTRS)

    Fraser, S. J.; Olson, R. L.; Leavens, W. M.

    1975-01-01

    The application of plasma gas technology to sterilization and decontamination of spacecraft components is considered. Areas investigated include: effective sterilizing ranges of four separate gases; lethal constituents of a plasma environment; effectiveness of plasma against a diverse group of microorganisms; penetrating efficiency of plasmas for sterilization; and compatibility of spacecraft materials with plasma environments. Results demonstrated that plasma gas, specifically helium plasma, is a highly effective sterilant and is compatible with spacecraft materials.

  7. Effects of Terminal Sterilization on PEG-Based Bioresorbable Polymers Used in Biomedical Applications.

    PubMed

    Bhatnagar, Divya; Dube, Koustubh; Damodaran, Vinod B; Subramanian, Ganesan; Aston, Kenneth; Halperin, Frederick; Mao, Meiyu; Pricer, Kurt; Murthy, N Sanjeeva; Kohn, Joachim

    2016-10-01

    The effects of ethylene oxide (EO), vaporized hydrogen peroxide (VHP), gamma (γ) radiation, and electron-beam (E-beam) on the physiochemical and morphological properties of medical device polymers are investigated. Polymers with ether, carbonate, carboxylic acid, amide and ester functionalities are selected from a family of poly(ethylene glycol) (PEG) containing tyrosine-derived polycarbonates (TyrPCs) to include slow, medium, fast, and ultrafast degrading polymers. Poly(lactic acid) (PLA) is used for comparison. Molecular weight ( M w ) of all tested polymers decreases upon gamma and E-beam, and this effect becomes more pronounced at higher PEG content. Gamma sterilization increases the glass transition temperature of polymers with high PEG content. EO esterifies the carboxylic acid groups in desaminotyrosol-tyrosine (DT) and causes significant degradation. VHP causes hydroxylation of the phenyl ring, and hydrolytic degradation. This study signifies the importance of the chemical composition when selecting a sterilization method, and provides suggested conditions for each of the sterilization methods.

  8. HDF-EOS 2 and HDF-EOS 5 Compatibility Library

    NASA Technical Reports Server (NTRS)

    Ullman, Richard; Bane, Bob; Yang, Jingli

    2008-01-01

    The HDF-EOS 2 and HDF-EOS 5 Compatibility Library contains C-language functions that provide uniform access to HDF-EOS 2 and HDF-EOS 5 files through one set of application programming interface (API) calls. ("HDFEOS 2" and "HDF-EOS 5" are defined in the immediately preceding article.) Without this library, differences between the APIs of HDF-EOS 2 and HDF-EOS 5 would necessitate writing of different programs to cover HDF-EOS 2 and HDF-EOS 5. The API associated with this library is denoted "he25." For nearly every HDF-EOS 5 API call, there is a corresponding he25 API call. If a file in question is in the HDF-EOS 5 format, the code reverts to the corresponding HDF-EOS 5 call; if the file is in the HDF-EOS 2 format, the code translates the arguments to HDF-EOS 2 equivalents (if necessary), calls the HDFEOS 2 call, and retranslates the results back to HDF-EOS 5 (if necessary).

  9. The application of a non-thermal plasma generated by gas-liquid gliding arc discharge in sterilization

    NASA Astrophysics Data System (ADS)

    Du, Chang Ming; Wang, Jing; Zhang, Lu; Xia Li, Hong; Liu, Hui; Xiong, Ya

    2012-01-01

    Gliding arc discharge has been investigated in recent years as an innovative physicochemical technique for contaminated water treatment at atmospheric pressure and ambient temperature. In this study we tested a gas-liquid gliding arc discharge reactor, the bacterial suspension of which was treated circularly. When the bacterial suspension was passed through the electrodes and circulated at defined flow rates, almost 100% of the bacteria were killed in less than 3.0 min. Experimental results showed that it is possible to achieve an abatement of 7.0 decimal logarithm units within only 30 s. Circulation flow rates and types of feeding gas caused a certain impact on bacteria inactivation, but the influences are not obvious. So, under the promise of sterilization effect, industrial applications can select their appropriate operating conditions. All inactivation curves presented the same three-phase profile showing an apparent sterilization effect. Analysis of the scanning electron microscope images of bacterial cells supports the speculation that the gas-liquid gliding arc discharge plasma is acting under various mechanisms driven essentially by oxidation and the effect of electric field. These results enhance the possibility of applying gas-liquid gliding arc discharge decontamination systems to disinfect bacterial-contaminated water. Furthermore, correlational research indicates the potential applications of this technology in rapid sterilization of medical devices, spacecraft and food.

  10. Optimization of a RF-generated CF4/O2 gas plasma sterilization process.

    PubMed

    Lassen, Klaus S; Nordby, Bolette; Grün, Reinar

    2003-05-15

    A sterilization process with the use of RF-generated (13.56 MHz) CF(4)/O(2) gas plasma was optimized in regards to power, flow rate, exposure time, and RF-system type. The dependency of the sporicidal effect on the spore inoculum positioning in the chamber of the RF systems was also investigated. Dried Bacillus stearothermophilus ATCC 7953 endospores were used as test organisms. The treatments were evaluated on the basis of survival curves and corresponding D values. The only parameter found to affect the sterilization process was the power of the RF system. Higher power resulted in higher kill. Finally, when the samples were placed more than 3-8 cm away from a centrally placed electrode in System 2, the sporicidal effect was reduced. The results are discussed and compared to results from the present literature. The RF excitation source is evaluated to be more appropriate for sterilization processes than the MW source. Copyright 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 65B: 239-244, 2003

  11. Application of a Dense Gas Technique for Sterilizing Soft Biomaterials

    PubMed Central

    Karajanagi, Sandeep S.; Yoganathan, Roshan; Mammucari, Raffaella; Park, Hyoungshin; Cox, Julian; Zeitels, Steven M.; Langer, Robert; Foster, Neil R.

    2017-01-01

    Sterilization of soft biomaterials such as hydrogels is challenging because existing methods such as gamma irradiation, steam sterilization, or ethylene oxide sterilization, while effective at achieving high sterility assurance levels (SAL), may compromise their physicochemical properties and biocompatibility. New methods that effectively sterilize soft biomaterials without compromising their properties are therefore required. In this report, a dense-carbon dioxide (CO2)-based technique was used to sterilize soft polyethylene glycol (PEG)-based hydrogels while retaining their structure and physicochemical properties. Conventional sterilization methods such as gamma irradiation and steam sterilization severely compromised the structure of the hydrogels. PEG hydrogels with high water content and low elastic shear modulus (a measure of stiffness) were deliberately inoculated with bacteria and spores and then subjected to dense CO2. The dense CO2-based methods effectively sterilized the hydrogels achieving a SAL of 10−7 without compromising the viscoelastic properties, pH, water-content, and structure of the gels. Furthermore, dense CO2-treated gels were biocompatible and non-toxic when implanted subcutaneously in ferrets. The application of novel dense CO2-based methods to sterilize soft biomaterials has implications in developing safe sterilization methods for soft biomedical implants such as dermal fillers and viscosupplements. PMID:21337339

  12. Exponential 6 parameterization for the JCZ3-EOS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGee, B.C.; Hobbs, M.L.; Baer, M.R.

    1998-07-01

    A database has been created for use with the Jacobs-Cowperthwaite-Zwisler-3 equation-of-state (JCZ3-EOS) to determine thermochemical equilibrium for detonation and expansion states of energetic materials. The JCZ3-EOS uses the exponential 6 intermolecular potential function to describe interactions between molecules. All product species are characterized by r*, the radius of the minimum pair potential energy, and {var_epsilon}/k, the well depth energy normalized by Boltzmann`s constant. These parameters constitute the JCZS (S for Sandia) EOS database describing 750 gases (including all the gases in the JANNAF tables), and have been obtained by using Lennard-Jones potential parameters, a corresponding states theory, pure liquid shockmore » Hugoniot data, and fit values using an empirical EOS. This database can be used with the CHEETAH 1.40 or CHEETAH 2.0 interface to the TIGER computer program that predicts the equilibrium state of gas- and condensed-phase product species. The large JCZS-EOS database permits intermolecular potential based equilibrium calculations of energetic materials with complex elemental composition.« less

  13. Sterilization of space hardware.

    NASA Technical Reports Server (NTRS)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  14. EOS Data Products Handbook. Volume 2

    NASA Technical Reports Server (NTRS)

    Parkinson, Claire L. (Editor); Greenstone, Reynold (Editor); Closs, James (Technical Monitor)

    2000-01-01

    The EOS Data Products Handbook provides brief descriptions of the data products that will be produced from a range of missions of the Earth Observing System (EOS) and associated projects. Volume 1, originally published in 1997, covers the Tropical Rainfall Measuring Mission (TRMM), the Terra mission (formerly named EOS AM-1), and the Data Assimilation System, while this volume, Volume 2, covers the Active Cavity Radiometer Irradiance Monitor Satellite (ACRIMSAT), Aqua, Jason-1, Landsat 7, Meteor 3M/Stratospheric Aerosol and Gas Experiment III (SAGE III). the Quick Scatterometer (QuikScat), the Quick Total Ozone Mapping Spectrometer (Quik-TOMS), and the Vegetation Canopy Lidar (VCL) missions. Volume 2 follows closely the format of Volume 1, providing a list of products and an introduction and overview descriptions of the instruments and data processing, all introductory to the core of the book, which presents the individual data product descriptions, organized into 11 topical chapters. The product descriptions are followed by five appendices, which provide contact information for the EOS data centers that will be archiving and distributing the data sets, contact information for the science points of contact for the data products, references, acronyms and abbreviations, and a data products index.

  15. Effects of low-temperature hydrogen peroxide gas plasma sterilization on in vitro cytotoxicity of poly(ϵ-caprolactone) (PCL).

    PubMed

    Franklin, Samuel Patrick; Stoker, Aaron M; Cockrell, Mary K; Pfeiffer, Ferris M; Sonny Bal, B; Cook, James L

    2012-01-01

    Our objective was to determine whether low-temperature hydrogen peroxide (H2O2) gas plasma sterilization of porous three-dimensional poly(ϵ-caprolactone) (PCL) constructs significantly inhibits cellular metabolism of canine chondrocytes. Porous cylindrical constructs were fabricated using fused deposition modeling and divided into four sterilization groups. Two groups were sterilized with low-temperature H2O2 gas plasma (LTGP) and constructs from one of those groups were subsequently rinsed with Dulbecco's Modified Essential Media (LTGPDM). Constructs in the other two groups were disinfected with either 70% isopropyl alcohol or exposure to UV light. Canine chondrocytes were seeded in 6-well tissue-culture plates and allowed to adhere prior to addition of PCL. Cellular metabolism was assessed by adding resazurin to the tissue-culture wells and assessing conversion of this substrate by viable cells to the fluorescent die resorufin. This process was performed at three times prior to addition of PCL and at four times after addition of PCL to the tissue-culture wells. Metabolism was not significantly different among the different tissue-culture wells at any of the 3 times prior to addition of PCL. Metabolism was significantly different among the treatment groups at 3 of 4 times after addition of PCL to the tissue culture wells. Metabolism was significantly lower with constructs sterilized by LTGP than all other treatment groups at all 3 of these times. We conclude that LTGP sterilization of PCL constructs resulted in significant cytotoxicity to canine chondrocytes when compared to PCL constructs disinfected with either UV light exposure or 70% isopropyl alcohol.

  16. Gamma inert sterilization: a solution to polyethylene oxidation?

    PubMed

    Medel, Francisco J; Kurtz, Steven M; Hozack, William J; Parvizi, Javad; Purtill, James J; Sharkey, Peter F; MacDonald, Daniel; Kraay, Matthew J; Goldberg, Victor; Rimnac, Clare M

    2009-04-01

    In the 1990s, oxidation was found to occur in ultra-high molecular weight polyethylene total joint replacement components following gamma irradiation and prolonged shelf aging in air. Orthopaedic manufacturers developed barrier packaging to reduce oxidation during and after radiation sterilization. The present study explores the hypothesis that polyethylene components sterilized in a low-oxygen environment undergo similar in vivo oxidative mechanisms as inserts sterilized in air. In addition, the potential influence of the different sterilization processes on the wear performance of the polyethylene components was examined. An analysis of oxidation, wear, and surface damage was performed for forty-eight acetabular liners and 123 tibial inserts. The mean implantation time was 12.3+/-3.7 years for thirty-one acetabular liners that had been gamma sterilized in air and 4.0+/-2.5 years for the seventeen acetabular liners that had been gamma sterilized in inert gas. The mean implantation time was 11.0+/-3.2 years for the twenty-six tibial inserts that had been sterilized in air and 2.8+/-2.2 years for the ninety-seven tibial inserts that had been gamma sterilized in inert gas. Oxidation and hydroperoxide levels were characterized in loaded and unloaded regions of the inserts. Measurable oxidation and oxidation potential were observed in all cohorts. The oxidation and hydroperoxide levels were regional. Surfaces with access to body fluids were more heavily oxidized than protected bearing surfaces were. This variation appeared to be greater in historical (gamma-in-air-sterilized) components. Regarding wear performance, historical and conventional acetabular liners showed similar wear penetration rates, whereas a low incidence of delamination was confirmed for the conventional tibial inserts in the first decade of implantation. The present study explores the impact of industry-wide changes in sterilization practices for polyethylene. We found lower oxidation and oxidation

  17. Effect of Sterilization Methods on Electrospun Poly(lactic acid) (PLA) Fiber Alignment for Biomedical Applications.

    PubMed

    Valente, T A M; Silva, D M; Gomes, P S; Fernandes, M H; Santos, J D; Sencadas, V

    2016-02-10

    Medically approved sterility methods should be a major concern when developing a polymeric scaffold, mainly when commercialization is envisaged. In the present work, poly(lactic acid) (PLA) fiber membranes were processed by electrospinning with random and aligned fiber alignment and sterilized under UV, ethylene oxide (EO), and γ-radiation, the most common ones for clinical applications. It was observed that UV light and γ-radiation do not influence fiber morphology or alignment, while electrospun samples treated with EO lead to fiber orientation loss and morphology changing from cylindrical fibers to ribbon-like structures, accompanied to an increase of polymer crystallinity up to 28%. UV light and γ-radiation sterilization methods showed to be less harmful to polymer morphology, without significant changes in polymer thermal and mechanical properties, but a slight increase of polymer wettability was detected, especially for the samples treated with UV radiation. In vitro results indicate that both UV and γ-radiation treatments of PLA membranes allow the adhesion and proliferation of MG 63 osteoblastic cells in a close interaction with the fiber meshes and with a growth pattern highly sensitive to the underlying random or aligned fiber orientation. These results are suggestive of the potential of both γ-radiation sterilized PLA membranes for clinical applications in regenerative medicine, especially those where customized membrane morphology and fiber alignment is an important issue.

  18. Sterilization mechanism of nitrogen gas plasma: induction of secondary structural change in protein.

    PubMed

    Sakudo, Akikazu; Higa, Masato; Maeda, Kojiro; Shimizu, Naohiro; Imanishi, Yuichiro; Shintani, Hideharu

    2013-07-01

    The mechanism of action on biomolecules of N₂ gas plasma, a novel sterilization technique, remains unclear. Here, the effect of N₂ gas plasma on protein structure was investigated. BSA, which was used as the model protein, was exposed to N₂ gas plasma generated by short-time high voltage pulses from a static induction thyristor power supply. N₂ gas plasma-treated BSA at 1.5 kilo pulses per second showed evidence of degradation and modification when assessed by Coomassie brilliant blue staining and ultraviolet spectroscopy at 280 nm. Fourier transform infrared spectroscopy analysis was used to determine the protein's secondary structure. When the amide I region was analyzed in the infrared spectra according to curve fitting and Fourier self-deconvolution, N₂ gas plasma-treated BSA showed increased α-helix and decreased β-turn content. Because heating decreased α-helix and increased β-sheet content, the structural changes induced by N₂ gas plasma-treatment of BSA were not caused by high temperatures. Thus, the present results suggest that conformational changes induced by N₂ gas plasma are mediated by mechanisms distinct from heat denaturation. © 2013 The Societies and Wiley Publishing Asia Pty Ltd.

  19. The V1V2 EOS for Detonation Products

    NASA Astrophysics Data System (ADS)

    Partom, Yehuda

    2010-10-01

    Many equations of state (EOS) for detonation products have been proposed and used. Some of them are in analytical form and some in tabular form. The most popular is the Jones-Wilkins-Lee (JWL) EOS. One of the main parameters of a product's EOS is the so-called adiabatic gamma along its main isentrope (γs). For JWL EOSs γs(V) varies in a nonmonotonic way. Going down from the CJ point along the main isentrope, it first increases to create a hump, and then, as V goes to infinity, gamma decreases to perfect gas-like behavior with gamma around 1.3. But according to Davis [1], γs(V) should decrease monotonically with V. Accordingly, in this article we investigate the following: (1) Is the hump in γs(V) necessary? and (2) Is it possible to construct a product's EOS with a monotonic γs(V) that is consistent with experimental data? We find that (1) it is possible to construct a product's EOS without a hump in γs(V); and (2) without a hump in γs(V) there are not enough degrees of freedom to reproduce cylinder test data.

  20. Hot super-dense compact object with particular EoS

    NASA Astrophysics Data System (ADS)

    Tito, E. P.; Pavlov, V. I.

    2018-03-01

    We show the possibility of existence of a self-gravitating spherically-symmetric equilibrium configuration for a neutral matter with neutron-like density, small mass M ≪ M_{⊙}, and small radius R ≪ R_{⊙}. We incorporate the effects of both the special and general theories of relativity. Such object may be formed in a cosmic cataclysm, perhaps an exotic one. Since the base equations of hydrostatic equilibrium are completed by the equation of state (EoS) for the matter of the object, we offer a novel, interpolating experimental data from high-energy physics, EoS which permits the existence of such compact system of finite radius. This EoS model possesses a critical state characterized by density ρc and temperature Tc. For such an object, we derive a radial distribution for the super-dense matter in "liquid" phase using Tolman-Oppenheimer-Volkoff equations for hydrostatic equilibrium. We demonstrate that a stable configuration is indeed possible (only) for temperatures smaller than the critical one. We derive the mass-radius relation (adjusted for relativistic corrections) for such small (M ≪ M_{⊙}) super-dense compact objects. The results are within the constraints established by both heavy-ion collision experiments and theoretical studies of neutron-rich matter.

  1. Emission characteristics of plastic syringes sterilized with ethylene oxide--a controlled study.

    PubMed

    Chien, Yeh-Chung; Su, Po-Chi; Lee, Lien-Hsiung; Chen, Chang-Yuh

    2009-11-01

    This study examined the emission characteristics of ethylene oxide (EO)-sterilized syringes under various environmental conditions, aiming to develop control strategies to minimize worker exposure. Experiments were performed in a facility in which temperature, relative humidity (RH), and air change rate (ACR) were controlled. Analytical results indicate that the main effects of the four test variables on kinetic parameters were statistically significant (p < 0.05), except for the effect of the product on the decay rate constant, the effect of ACR on maximum EO concentration, and effect of RH on the area under the curve-days 1 and 2. The interactive effects among test variables were also evident, indicating complex emission behaviors. The mean EO emission factors during the days 1 and 2 and at the 48th hour for the 1- and 30-ml products were 2302, 1301, and 1031 mg/m(3)/h, and 871, 490, and 381 mg/m(3)/h, respectively. The times required for air EO concentrations from tested products to return to approximately 0 and 1 ppm (permissible limit) were 417 and 218 h, respectively. Plastic content, temperature, RH, and ACR affected EO emissions. ACR is an achievable means of control; however, the aeration area/system should be isolated to ensure adequate ventilation is achieved.

  2. Development and assessment of sterility of a closed-system pediatric peritoneal dialysis.

    PubMed

    Biazi, Ana Paula Pereira; Croti, Ulisses Alexandre; Braile, Domingo Marcolino; Oliveira, Marcos Aurélio Barboza de; Costa, Jane Gonçalves Soares; Cardoso, Lucas Monteiro

    2009-01-01

    To develop an easy-handling totally closed pediatric peritoneal dialysis system and assess the sterility assurance level. From February to December 2008 was designed and developed a closed-system pediatric peritoneal dialysis at the Bioengineering Division of Braile Biomédica Indústria, Comércio e Representações S/A. Twenty systems were manufactured and submitted to sterility assurance level testing, and were divided into Group A (10)--using the sterility test--and B (10)--ethylene oxide gas penetration. In Group A, the sterility test was negative for bacteria and fungi proliferation within 14 days in all systems. In Group B, the gas penetration test showed that there was gas penetration in all points assessed. It was possible to develop a new easy-handling closed-system pediatric peritoneal dialysis and ensure its sterility.

  3. The Earth Observing System. [instrument investigations for flight on EOS-A satellite

    NASA Technical Reports Server (NTRS)

    Wilson, Stan; Dozier, Jeff

    1991-01-01

    The Earth Observing System (EOS), the centerpiece of NASA's Mission to Planet Earth, is to study the interactions of the atmosphere, land, oceans, and living organisms, using the perspective of space to observe the earth as a global environmental system. To better understand the role of clouds in global change, EOS will measure incoming and emitted radiation at the top of the atmosphere. Then, to study characteristics of the atmosphere that influence radiation transfer between the top of the atmosphere and the surface, EOS wil observe clouds, water vapor and cloud water, aerosols, temperature and humidity, and directional effects. To elucidate the role of anthropogenic greenhouse gas and terrestrial and marine plants as a source or sink for carbon, EOS will observe the biological productivity of lands and oceans. EOS will also study surface properties that affect biological productivity at high resolution spatially and spectrally.

  4. Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens.

    PubMed

    Alfa, M J; DeGagne, P; Olson, N; Hizon, R

    1998-10-01

    The aim of this study was to determine how well peracetic acid liquid chemical sterilization (LCPAS) killed test organisms in the presence of 10% fetal bovine serum and 0.65% salt challenge (RPMI-S) compared with a 100% ethylene oxide (ETO) sterilizer and an ETO hydrochlorofluorocarbon (ETO-HCFC) sterilization method with long (125 cm), narrow (3-mm internal diameter) flexible lumens as the test carrier. The inoculated lumens were dried overnight before processing. The test organisms included Mycobacterium chelonei, Enterococcus faecalis, and Bacillus subtilis. For all 3 organisms tested, the LCPAS process resulted in a 6 log10 reduction in bacterial load compared with a 2.5 log10 to 6 log10 reduction for the 100% ETO and ETO-HCFC sterilizers. Sterilization was achieved for 100%, 61%, and 67% of the lumen test carriers for the LCPAS, 100% ETO, and ETO-HCFC sterilizers, respectively. The data indicate that of the sterilization methods evaluated, LCPAS was the most effective for sterilizing narrow flexible lumens in the presence of residual inorganic and organic soil. This effectiveness was achieved through a combination of organism wash-off and peracetic acid sterilant killing of organisms. Salt was the major compounding factor for effective ETO gas sterilization, because carriers inoculated with organisms in 10% fetal bovine serum alone all were sterilized by both 100% ETO and ETO-HCFC sterilization methods. Our data support the critical need to ensure adequate precleaning of narrow flexible lumen endoscopes before any sterilization method.

  5. HDF-EOS Dump Tools

    NASA Astrophysics Data System (ADS)

    Prasad, U.; Rahabi, A.

    2001-05-01

    The following utilities developed for HDF-EOS format data dump are of special use for Earth science data for NASA's Earth Observation System (EOS). This poster demonstrates their use and application. The first four tools take HDF-EOS data files as input. HDF-EOS Metadata Dumper - metadmp Metadata dumper extracts metadata from EOS data granules. It operates by simply copying blocks of metadata from the file to the standard output. It does not process the metadata in any way. Since all metadata in EOS granules is encoded in the Object Description Language (ODL), the output of metadmp will be in the form of complete ODL statements. EOS data granules may contain up to three different sets of metadata (Core, Archive, and Structural Metadata). HDF-EOS Contents Dumper - heosls Heosls dumper displays the contents of HDF-EOS files. This utility provides detailed information on the POINT, SWATH, and GRID data sets. in the files. For example: it will list, the Geo-location fields, Data fields and objects. HDF-EOS ASCII Dumper - asciidmp The ASCII dump utility extracts fields from EOS data granules into plain ASCII text. The output from asciidmp should be easily human readable. With minor editing, asciidmp's output can be made ingestible by any application with ASCII import capabilities. HDF-EOS Binary Dumper - bindmp The binary dumper utility dumps HDF-EOS objects in binary format. This is useful for feeding the output of it into existing program, which does not understand HDF, for example: custom software and COTS products. HDF-EOS User Friendly Metadata - UFM The UFM utility tool is useful for viewing ECS metadata. UFM takes an EOSDIS ODL metadata file and produces an HTML report of the metadata for display using a web browser. HDF-EOS METCHECK - METCHECK METCHECK can be invoked from either Unix or Dos environment with a set of command line options that a user might use to direct the tool inputs and output . METCHECK validates the inventory metadata in (.met file) using The

  6. Investigation of methods for sterilization of potting compounds and mated surfaces

    NASA Technical Reports Server (NTRS)

    Tulius, J. J.; Daley, D. J.; Phillips, G. B.

    1972-01-01

    The feasibility of using formaldehyde-liberating synthetic resins or polymers for the sterilization of potting compounds, mated and occluded areas, and spacecraft surfaces was demonstrated. The detailed study of interrelated parameters of formaldehyde gas sterilization revealed that efficient cycle conditions can be developed for the sterilization of spacecraft components. It was determined that certain parameters were more important than others in the development of cycles for specific applications. The use of formaldehyde gas for the sterilization of spacecraft components provides NASA with a highly efficient method which is inexpensive, reproducible, easily quantitated, materials compatible, operationally simple, generally non-hazardous and not thermally destructive.

  7. EOS developments

    NASA Astrophysics Data System (ADS)

    Sindrilaru, Elvin A.; Peters, Andreas J.; Adde, Geoffray M.; Duellmann, Dirk

    2017-10-01

    CERN has been developing and operating EOS as a disk storage solution successfully for over 6 years. The CERN deployment provides 135 PB and stores 1.2 billion replicas distributed over two computer centres. Deployment includes four LHC instances, a shared instance for smaller experiments and since last year an instance for individual user data as well. The user instance represents the backbone of the CERNBOX service for file sharing. New use cases like synchronisation and sharing, the planned migration to reduce AFS usage at CERN and the continuous growth has brought EOS to new challenges. Recent developments include the integration and evaluation of various technologies to do the transition from a single active in-memory namespace to a scale-out implementation distributed over many meta-data servers. The new architecture aims to separate the data from the application logic and user interface code, thus providing flexibility and scalability to the namespace component. Another important goal is to provide EOS as a CERN-wide mounted filesystem with strong authentication making it a single storage repository accessible via various services and front- ends (/eos initiative). This required new developments in the security infrastructure of the EOS FUSE implementation. Furthermore, there were a series of improvements targeting the end-user experience like tighter consistency and latency optimisations. In collaboration with Seagate as Openlab partner, EOS has a complete integration of OpenKinetic object drive cluster as a high-throughput, high-availability, low-cost storage solution. This contribution will discuss these three main development projects and present new performance metrics.

  8. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    PubMed

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  9. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds

    PubMed Central

    Calhoun, Chistopher S.; Grotewold, Erich; Brkljacic, Jelena

    2017-01-01

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  10. Viking heat sterilization - Progress and problems

    NASA Technical Reports Server (NTRS)

    Daspit, L. P.; Cortright, E. M.; Stern, J. A.

    1974-01-01

    The Viking Mars landers to be launched in 1975 will carry experiments in biology, planetology, and atmospheric physics. A terminal dry-heat sterilization process using an inert gas was chosen to meet planetary quarantine requirements and preclude contamination of the biology experiment by terrestrial organisms. Deep sterilization is performed at the component level and terminal surface sterilization at the system level. Solutions to certain component problems relating to sterilization are discussed, involving the gyroscope, tape recorder, battery, electronic circuitry, and outgassing. Heat treatment placed special requirements on electronic packaging, including fastener preload monitoring and solder joints. Chemical and physical testing of nonmetallic materials was performed to establish data on their behavior in heat-treatment and vacuum environments. A Thermal Effects Test Model and a Proof Test Capsule were used. It is concluded that a space vehicle can be designed and fabricated to withstand heat sterilization requirements.

  11. The 1991 EOS reference handbook

    NASA Technical Reports Server (NTRS)

    Dokken, David (Editor)

    1991-01-01

    The following topics are covered: (1) The Global Change Research Program; (2) The Earth Observing System (EOS) goal and objectives; (3) primary EOS mission requirements; (4) EOS science; (5) EOS Data and Information System (EOSDIS) architecture; (6) data policy; (7) international cooperation; (8) plans and status; (9) the role of the National Oceanic and Atmospheric Administration; (10) The Global Fellowship Program; (11) management of EOS; (12) mission elements; (13) EOS instruments; (14) interdisciplinary science investigations; (15) points of contact; and (16) acronyms and abbreviations.

  12. The RealGas and RealGasH2O options of the TOUGH+ code for the simulation of coupled fluid and heat flow in tight/shale gas systems

    EPA Science Inventory

    We developed two new EOS additions to the TOUGH+ family of codes, the RealGasH2O and RealGas. The RealGasH2O EOS option describes the non-isothermal two-phase flow of water and a real gas mixture in gas reservoirs, with a particular focus in ultra-tight (such as tight-sand and sh...

  13. Sterilization Effect of Wet Oxygen Plasma in the Bubbling Method.

    PubMed

    Tamazawa, Kaoru; Shintani, Hideharu; Tamazawa, Yoshinori; Shimauchi, Hidetoshi

    2015-01-01

    A new low-temperature sterilization method to replace the ethylene oxide gas sterilization is needed. Strong bactericidal effects of OH and O2H radicals are well known. The purpose of this study was to evaluate the sterilization effect of wet oxygen ("O2+H2O") plasma in the bubbling method, confirming the effect of humidity. Sterility assurance was confirmed by using a biological indicator (Geobacillus stearothermophilus ATCC7953, Namsa, USA). One hundred and eight samples (10(5) spores/carrier) were divided into three groups of 36 in each for treatment with a different type of gas (O2, O2+H2O, Air+H2O). Plasma processing was conducted using a plasma ashing apparatus (13.56 MHz, PACK-3(®), Y. A. C., Japan) under various gas pressures (13, 25, 50 Pa) and gas flows (50, 100, 200 sccm). Fixed plasma treatment parameters were power at 150 W, temperature of 60 ℃, treatment time of 10 min. The samples after treatment were incubated in trypticase soy broth at 58 ℃ for 72 h. The negative culture rate in the "O2+H2O" group was significantly (Mantel-Haenszel procedure, p<0.001) higher than in the other gas groups. It is suggested that the significant sterilization effect of the "O2+H2O" group depends on the bubbling method which is the method of introducing vapor into the chamber. The bubbling method seems able to generate OH and O2H radicals in a stable way.

  14. Eosinophilic Esophagitis (EoE)

    MedlinePlus

    ... the main cause of EoE in a large number of patients. Allergists are experts in evaluating and treating EoE related to food allergies. However the relationship between food allergy and EoE is complex. In many types of food allergy, the triggers ...

  15. Vector Data Model: A New Model of HDF-EOS to Support GIS Applications in EOS

    NASA Astrophysics Data System (ADS)

    Chi, E.; Edmonds, R d

    2001-05-01

    NASA's Earth Science Data Information System (ESDIS) project has an active program of research and development of systems for the storage and management of Earth science data for Earth Observation System (EOS) mission, a key program of NASA Earth Science Enterprise. EOS has adopted an extension of the Hierarchical Data Format (HDF) as the format of choice for standard product distribution. Three new EOS specific datatypes - point, swath and grid - have been defined within the HDF framework. The enhanced data format is named HDF-EOS. Geographic Information Systems (GIS) are used by Earth scientists in EOS data product generation, visualization, and analysis. There are two major data types in GIS applications, raster and vector. The current HDF-EOS handles only raster type in the swath data model. The vector data model is identified and developed as a new HDFEOS format to meet the requirements of scientists working with EOS data products in vector format. The vector model is designed using a topological data structure, which defines the spatial relationships among points, lines, and polygons. The three major topological concepts that the vector model adopts are: a) lines connect to each other at nodes (connectivity), b) lines that connect to surround an area define a polygon (area definition), and c) lines have direction and left and right sides (contiguity). The vector model is implemented in HDF by mapping the conceptual model to HDF internal data models and structures, viz. Vdata, Vgroup, and their associated attribute structures. The point, line, and polygon geometry and attribute data are stored in similar tables. Further, the vector model utilizes the structure and product metadata, which characterize the HDF-EOS. Both types of metadata are stored as attributes in HDF-EOS files, and are encoded in text format by using Object Description Language (ODL) and stored as global attributes in HDF-EOS files. EOS has developed a series of routines for storing

  16. Sterilization processes. Meeting the demands of today's health care technology.

    PubMed

    Crow, S

    1993-09-01

    Universal Precautions dictate sterilization for all invasive equipment that break the blood barrier; however, current methods of sterilization, such as steam and ethylene oxide gas (ETO), are not compatible with many of the delicate, heat-sensitive surgical instruments used in modern health care. In addition, traditional sterilization methods are often too time consuming for practical use in the operating room. Clearly, new sterilization processes need to be developed. In this article, the criteria modern sterilization processes must meet and how some manufacturers plan to meet this challenge are discussed. In addition, the pros and cons of using peracetic acid (the newest sterilization process currently available) are examined.

  17. Toxic effect of ethylene-oxide-sterilized freeze-dried bone allograft on human gingival fibroblasts.

    PubMed

    Kudryk, V L; Scheidt, M J; McQuade, M J; Sutherland, D E; VanDyke, T E; Hollinger, J O

    1992-11-01

    Freeze-dried bone allograft (FDBA) which either had or had not been sterilized by exposure to ethylene oxide (EtO) prior to lyophilization was obtained from two commercial sources. EtO-sterilized FDBA was reexposed to EtO as a positive control. Gas chromatograph assays revealed that three out of four commercially obtained EtO sterilized FDBA had no detectable EtO, with one sample having 0.21 parts per million (PPM). Surprisingly, 0.24 PPM was detected in one sample which had not been sterilized with EtO gas. This was presumed due to contamination from a gas-sterilized rubber stopper. In the cell toxicity study, FDBA and human gingival fibroblasts (HGF) were added simultaneously, incubated for 72 h, and fixed and stained. Samples of FDBA sterilized with EtO which were free of EtO did not alter HGF growth. However, the positive control FDBA which contained 0.72 PPM EtO had a deleterious effect on HGF. FDBA with EtO residuals caused morphologic change in HGF.

  18. HDF-EOS Web Server

    NASA Technical Reports Server (NTRS)

    Ullman, Richard; Bane, Bob; Yang, Jingli

    2008-01-01

    A shell script has been written as a means of automatically making HDF-EOS-formatted data sets available via the World Wide Web. ("HDF-EOS" and variants thereof are defined in the first of the two immediately preceding articles.) The shell script chains together some software tools developed by the Data Usability Group at Goddard Space Flight Center to perform the following actions: Extract metadata in Object Definition Language (ODL) from an HDF-EOS file, Convert the metadata from ODL to Extensible Markup Language (XML), Reformat the XML metadata into human-readable Hypertext Markup Language (HTML), Publish the HTML metadata and the original HDF-EOS file to a Web server and an Open-source Project for a Network Data Access Protocol (OPeN-DAP) server computer, and Reformat the XML metadata and submit the resulting file to the EOS Clearinghouse, which is a Web-based metadata clearinghouse that facilitates searching for, and exchange of, Earth-Science data.

  19. EOS mapping accuracy study

    NASA Technical Reports Server (NTRS)

    Forrest, R. B.; Eppes, T. A.; Ouellette, R. J.

    1973-01-01

    Studies were performed to evaluate various image positioning methods for possible use in the earth observatory satellite (EOS) program and other earth resource imaging satellite programs. The primary goal is the generation of geometrically corrected and registered images, positioned with respect to the earth's surface. The EOS sensors which were considered were the thematic mapper, the return beam vidicon camera, and the high resolution pointable imager. The image positioning methods evaluated consisted of various combinations of satellite data and ground control points. It was concluded that EOS attitude control system design must be considered as a part of the image positioning problem for EOS, along with image sensor design and ground image processing system design. Study results show that, with suitable efficiency for ground control point selection and matching activities during data processing, extensive reliance should be placed on use of ground control points for positioning the images obtained from EOS and similar programs.

  20. Stability of an ophthalmic formulation of polyhexamethylene biguanide in gamma-sterilized and ethylene oxide sterilized low density polyethylene multidose eyedroppers

    PubMed Central

    Wasiak, Mathieu; Jouannet, Mireille; Sautou, Valérie

    2018-01-01

    Background Polyhexamethylene biguanide (PHMB) eye drops are a frequently used medication to treat Acanthamoeba keratitis. In the absence of marketed PHMB eye drops, pharmacy-compounding units are needed to prepare this much needed treatment, but the lack of validated PHMB stability data severely limits their conservation by imposing short expiration dates after preparation. In this study we aim to assess the physicochemical and microbiological stability of a 0.2 mg/mL PHMB eye drop formulation stored in two kinds of polyethylene bottles at two different temperatures. Methods A liquid chromatography coupled with diode array detector stability-indicating method was validated to quantify PHMB, using a cyanopropyl bonded phase (Agilent Zorbax Eclipse XDB-CN column 4.6 × 75 mm with particle size of 3.5 μm) and isocratic elution consisting of acetonitrile/deionized water (3/97 v/v) at a flow rate of 1.3 mL/min. PHMB eye drops stability was assessed for 90 days of storage at 5 and 25 °C in ethylene oxide sterilized low density polyethylene (EOS-LDPE) and gamma sterilized low density polyethylene (GS-LDPE) bottles. The following analyses were performed: visual inspection, PHMB quantification and breakdown products (BPs) screening, osmolality and pH measurements, and sterility assessment. PHMB quantification and BP screening was also performed on the drops emitted from the multidose eyedroppers to simulate in-use condition. Results The analytical method developed meets all the qualitative and quantitative criteria for validation with an acceptable accuracy and good linearity, and is stability indicating. During 90 days of storage, no significant decrease of PHMB concentration was found compared to initial concentration in all stored PHMB eye drops. However, BP were found at day 30 and at day 90 of monitoring in both kind of bottles, stored at 5 and 25 °C, respectively. Although no significant variation of osmolality was found and sterility was maintained during 90 days

  1. [What should be the length and inner diameter of the testing device for microbiological efficacy testing of formaldehyde gas sterilization methods?].

    PubMed

    Spicher, G; Borchers, U

    1984-10-01

    The series of tests described in a preceding publication (Spicher and Borchers, 1983) has been continued in a modified way. This time, the dependency of the microbiological test results of a formaldehyde gas sterilization procedure on length and inner diameter of the tubes serving as test pieces was examined. The tubes were 1 or 2 m in length with an inner diameter of 1 or 2 mm. The tests were performed with four different preparations of bioindicators. Spores of Bac. stearothermophilus served as test germs. The preparations differed in the type of suspension used for the preparation of the bioindicators: distilled water, diluted blood (10%), undiluted blood, 10% albumin solution. The spore suspensions had been dried on linen thread. During the test procedure, the bioindicators were located near the sealed end of the tube. After completion of the sterilization procedure, the bioindicators were examined for viable germs. In tubes of identical length, the frequency of indicators carrying viable germs was always higher in those of 1 mm than in those of 2 mm inner diameter. In tubes of identical inner diameter, the frequency of indicators carrying viable germs in those of 2 m length was always higher than in those of 1 m length. This regularity was independent of the type of bioindicators used. The bioindicators for the preparation of which a 10% albumin solution had been employed showed the highest resistance. A somewhat lower resistance was found for the bioindicators prepared with undiluted blood. The bioindicators for which the spores had been suspended in diluted blood proved to have the lowest resistance. If the spores had been suspended in distilled water, the resistance of the bioindicators was a little lower than that of those suspended in undiluted blood, but was higher than that of the dried spores with diluted blood. The test results confirm the effectiveness of the method proposed earlier, i.e. to deposit the bioindicators in special test pieces (e

  2. Probing a steep EoS for dark energy with latest observations

    NASA Astrophysics Data System (ADS)

    Jaber, Mariana; Macorra, Axel de la

    2018-01-01

    We present a parametrization for the Dark Energy Equation of State "EoS" which has a rich structure, performing a transition at pivotal redshift zT between the present day value w0 to an early time wi =wa +w0 ≡ w(z ≫ 0) with a steepness given in terms of q parameter. The proposed parametrization is w =w0 +wa(z /zT) q /(1 +(z /zT)) q , with w0, wi, q and zT constant parameters. It reduces to the widely used EoS w =w0 +wa(1 - a) for zT = q = 1 . This transition is motivated by scalar field dynamics such as for example quintessence models. We study if a late time transition is favored by BAO measurements combined with local determination of H0 and information from the CMB. We find that our dynamical DE model allows to simultaneously fit H0 from local determinations and Planck CMB measurements, alleviating the tension obtained in a ΛCDM model. We obtain a smaller χ2 in our DE model than in ΛCDM showing that a dynamical DE is preferred with a reduction of 4.8%, 20.2% and 42.8% using BAO + H0, BAO + CMB and BAO + CMB + H0 datasets, respectively. However due to the increased number of free parameters in the EoS information criteria favors ΛCDM over our DE model at this stage. Nevertheless it is crucial to obtain the dynamics of DE from the observational data to show the path for theoretical DE models based on fundamental physics.

  3. Summary of EOS flight dynamics analysis

    NASA Technical Reports Server (NTRS)

    Newman, Lauri Kraft; Folta, David C.

    1995-01-01

    From a flight dynamics perspective, the Earth Observing System (EOS) spacecraft present a number of challenges to mission designers. The Flight Dynamics Support Branch of NASA GSFC has examined a number of these challenges, including managing the EOS constellation, disposing of the spacecraft at the end-of-life (EOL), and achieving the appropriate mission orbit given launch vehicle and ascent propulsion constraints. The EOS program consists of a number of spacecraft including EOS-AM, an ascending node spacecraft, EOS-PM, a descending node spacecraft, the EOS Chemistry mission (EOS-CHEM), the EOS Altimetry Laser (EOS-LALT), and the EOS-Altimetry Radar (EOS-RALT). The orbit characteristics of these missions are presented. In order to assure that downlinking data from each spacecraft will be possible without interference between any two spacecraft, a careful examination of the relationships between spacecraft and how to maintain the spacecraft in a configuration which would minimize these communications problems must be made. The FDSB has performed various analyses to determine whether the spacecraft will be in a position to interfere with each other, how the orbit dynamics will change the relative positioning of the spacecraft over their lifetimes, and how maintenance maneuvers could be performed, if needed, to minimize communications problems. Prompted by an activity at NASA HQ to set guidelines for spacecraft regarding their end-of-life dispositions, much analysis has also been performed to determine the spacecraft lifetime of EOS-AM1 under various conditions, and to make suggestions regarding the spacecraft disposal. In performing this analysis, some general trends have been observed in lifetime calculations. The paper will present the EOS-AM1 lifetime results, comment on general reentry conclusions, and discuss how these analyses reflect on the HQ NMI. Placing the EOS spacecraft into their respective mission orbits involves some intricate maneuver planning to

  4. A sterilization system using ultraviolet photochemical reactions based on nitrous oxide and oxygen gases.

    PubMed

    Ohnishi, Yasutaka; Matsumoto, Hiroyuki; Iwamori, Satoru

    2016-03-01

    Active oxygen species (AOS) generated under ultraviolet (UV) lamps can be applied for various industrial processes owing to extremely strong oxidative abilities. We have already reported on an application of the AOS for a sterilization process of microorganisms. Here, a sterilization method using active oxygen generated under ultraviolet (UV) lamps introducing nitrous oxide (N2O) and oxygen gases into a vacuum chamber was investigated. Nitrogen dioxide (NO2) gas was readily produced from N2O by UV photochemical reactions under the low-pressure mercury lamp and then used to sterilize medical devices. We compared the ability of the N2O gas to sterilize Geobacillus stearothermophilus spores with those of conventional methods. Successful sterilization of spores on various biological indicators was achieved within 60 min, not only in sterilization bags but also in a lumen device. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. THE POSSIBLE USE OF IONIZING RADIATION FOR THE STERILIZATION OF CERTAIN BIOLOGICAL PREPARATIONS. I. THE INFLUENCE OF IONIZING RADIATION UPON GAS-GANGRENE AND TETANUS ANTI-SERUM (SEROLOGICAL AND ELECTROPHORETIC INVESTIGATION)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goncharenko, I.M.

    1961-12-01

    The antltoxic properties and the relative proportion of the protein fractions of gas-gangrene and tetanus antisera were studied. The results show that the sterilization of dried antisera with gamma rays caused no marked decrease in the antitoxin titre. Similar results were obtained with liquid antisera containing 0.3% mercamine. However, crude and concentrated liquid antisera after sterilization by radiation showed a marked decrease in antitoxin titre. Under the usual conditions, sterilization of liquid antisera appears to be inadvsable, not-withstanding the simpliclty, convenience, and reliabillty of the method; sterilization of dried antisera, however, offers better prospects. (P. C.H.)

  6. EOS Directory

    NASA Technical Reports Server (NTRS)

    1994-01-01

    This Earth Observing System (EOS) directory is divided into two main sections: white and yellow pages. The white pages list alphabetically the names and addresses -- including e-mail, phone, and fax when available -- of all individuals involved with EOS, from graduate students to panel members to program management and more. The yellow pages list the names, affiliation, and phone number of participants divided by project management, program management, individual project participants, interdisciplinary investigations (listed alphabetically by PI), the Science Executive Committee, various panels, platforms, working groups, fellowships, and contractors.

  7. HDF-EOS 5 Validator

    NASA Technical Reports Server (NTRS)

    Ullman, Richard; Bane, Bob; Yang, Jingli

    2008-01-01

    A computer program partly automates the task of determining whether an HDF-EOS 5 file is valid in that it conforms to specifications for such characteristics as attribute names, dimensionality of data products, and ranges of legal data values. ["HDF-EOS" and variants thereof are defined in "Converting EOS Data From HDF-EOS to netCDF" (GSC-15007-1), which is the first of several preceding articles in this issue of NASA Tech Briefs.] Previously, validity of a file was determined in a tedious and error-prone process in which a person examined human-readable dumps of data-file-format information. The present software helps a user to encode the specifications for an HDFEOS 5 file, and then inspects the file for conformity with the specifications: First, the user writes the specifications in Extensible Markup Language (XML) by use of a document type definition (DTD) that is part of the program. Next, the portion of the program (denoted the validator) that performs the inspection is executed, using, as inputs, the specifications in XML and the HDF-EOS 5 file to be validated. Finally, the user examines the output of the validator.

  8. Exploiting novel sterilization techniques for porous polyurethane scaffolds.

    PubMed

    Bertoldi, Serena; Farè, Silvia; Haugen, Håvard Jostein; Tanzi, Maria Cristina

    2015-05-01

    Porous polyurethane (PU) structures raise increasing interest as scaffolds in tissue engineering applications. Understanding the effects of sterilization on their properties is mandatory to assess their potential use in the clinical practice. The aim of this work is the evaluation of the effects of two innovative sterilization techniques (i.e. plasma, Sterrad(®) system, and ozone) on the morphological, chemico-physical and mechanical properties of a PU foam synthesized by gas foaming, using water as expanding agent. In addition, possible toxic effects of the sterilization were evaluated by in vitro cytotoxicity tests. Plasma sterilization did not affect the morphological and mechanical properties of the PU foam, but caused at some extent degradative phenomena, as detected by infrared spectroscopy. Ozone sterilization had a major effect on foam morphology, causing the formation of new small pores, and stronger degradation and oxidation on the structure of the material. These modifications affected the mechanical properties of the sterilized PU foam too. Even though, no cytotoxic effects were observed after both plasma and ozone sterilization, as confirmed by the good values of cell viability assessed by Alamar Blue assay. The results here obtained can help in understanding the effects of sterilization procedures on porous polymeric scaffolds, and how the scaffold morphology, in particular porosity, can influence the effects of sterilization, and viceversa.

  9. Study of Inactivation Factors in Low Temperature Surface-wave Plasma Sterilization

    NASA Astrophysics Data System (ADS)

    Singh, Mrityunjai Kumar; Xu, Lei; Ogino, Akihisa; Nagatsu, Masaaki

    In this study we investigated the low temperature surface-wave plasma sterilization of directly and indirectly exposed Geobacillus stearothermophilus spores with a large-volume microwave plasma device. The air-simulated gas mixture was used to produce the plasma. The water vapor addition to the gas mixture improved the sterilization efficiency significantly. The effect of ultraviolet photons produced along with plasma to inactivate the spores was studied using a separate chamber, which was evacuated to less than one mTorr and was observed that spores were sterilized within 60 min. The scanning electron microscopy images revealed no significant changes in the actual size of the spores with that of untreated spores despite the survival curve shown that the spores were inactivated.

  10. Opacplot2: Enabling tabulated EoS and opacity compatibility for HEDLP simulations with the FLASH code

    NASA Astrophysics Data System (ADS)

    Laune, Jordan; Tzeferacos, Petros; Feister, Scott; Fatenejad, Milad; Yurchak, Roman; Flocke, Norbert; Weide, Klaus; Lamb, Donald

    2017-10-01

    Thermodynamic and opacity properties of materials are necessary to accurately simulate laser-driven laboratory experiments. Such data are compiled in tabular format since the thermodynamic range that needs to be covered cannot be described with one single theoretical model. Moreover, tabulated data can be made available prior to runtime, reducing both compute cost and code complexity. This approach is employed by the FLASH code. Equation of state (EoS) and opacity data comes in various formats, matrix-layouts, and file-structures. We discuss recent developments on opacplot2, an open-source Python module that manipulates tabulated EoS and opacity data. We present software that builds upon opacplot2 and enables easy-to-use conversion of different table formats into the IONMIX format, the native tabular input used by FLASH. Our work enables FLASH users to take advantage of a wider range of accurate EoS and opacity tables in simulating HELP experiments at the National Laser User Facilities.

  11. Relic keV sterile neutrinos and reionization.

    PubMed

    Biermann, Peter L; Kusenko, Alexander

    2006-03-10

    A sterile neutrino with a mass of several keV can account for cosmological dark matter, as well as explain the observed velocities of pulsars. We show that x rays produced by the decays of these relic sterile neutrinos can boost the production of molecular hydrogen, which can speed up the cooling of gas and the early star formation, which can, in turn, lead to a reionization of the Universe at a high enough redshift to be consistent with the Wilkinson Microwave Anisotropy Probe results.

  12. Development of atmospheric pressure plasma needle jet for sterilization applications

    NASA Astrophysics Data System (ADS)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Soon, Chin Fhong; Sahdan, Mohd Zainizan; Lias, Jais; Wibowo, Kusnanto Mukti; Bakar, Ahmad Shuhaimi Abu; Arshad, Mohd Khairuddin Md; Hashim, Uda; Nayan, Nafarizal

    2017-09-01

    Inactivation of bacteria or sterilization has been a major issue in the medical field, especially regarding of human safety, whereby, in a huge scenario fatality can be caused by hazardous bacteria. Often, E-coli as gram-negative bacteria are selected as a key indicator of proper sterilization process as E-coli is tough and dormant bacteria. The technology in sterilization has moved on from chemical, wet and irradiation sterilization to a high promising device such as atmospheric pressure plasma needle jet (APPNJ). It has been reported that atmospheric pressure plasma has provided bundle of advantages over earlier sterilization process. The APPNJ is developed in our lab using high frequency and high voltage neon transformer power supply connected to copper needle and copper sheet electrodes. The gas discharge is Ar gas flowing at 40 L/min through a quartz glass tube. The E-coli bacteria are self-cultured from waste water and then treated with APPNJ. The treatment processes are run into two difference gaps between the plasma orifice and sample with various treatment times. Only 40s is required by direct treatment to achieve 100% killing of E-coli. On the other hand, indirect treatment has inactivated 50% of the E-coli in 40s. In this study, direct and indirect effect of APPNJ to the E-coli can be observed which can be utilized into sterilization of bio-compatible material applications.

  13. Spacecraft sterilization.

    NASA Technical Reports Server (NTRS)

    Kalfayan, S. H.

    1972-01-01

    Spacecraft sterilization is a vital factor in projects for the successful biological exploration of other planets. The microorganisms of major concern are the fungi and bacteria. Sterilization procedures are oriented toward the destruction of bacterial spores. Gaseous sterilants are examined, giving attention to formaldehyde, beta-propiolactone, ethylene oxide, and the chemistry of the bactericidal action of sterilants. Radiation has been seriously considered as another method for spacecraft sterilization. Dry heat sterilization is discussed together with the effects of ethylene oxide decontamination and dry heat sterilization on materials.

  14. Effects of supercritical carbon dioxide sterilization on polysaccharidic membranes for surgical applications.

    PubMed

    Scognamiglio, F; Blanchy, M; Borgogna, M; Travan, A; Donati, I; Bosmans, J W A M; Foulc, M P; Bouvy, N D; Paoletti, S; Marsich, E

    2017-10-01

    Sterilization methods such as ɣ-irradiation, steam sterilization and ethylene oxide gas treatment can have negative effects on molecular structure and properties of polysaccharide-based biomaterials. In this perspective, the use of supercritical carbon dioxide (scCO 2 ) has been proposed as an alternative method for biomaterial sterilization. In this work, chemical, mechanical and biological properties of polysaccharidic membranes for surgical applications were investigated after sterilization by scCO 2 . Four sets of sterilizing conditions were considered and SEC analyses were performed in order to identify the one with lower impact on the polysaccharidic matrix of membranes (alginate). Mechanical tests showed that the resistance of membranes was slightly affected after sterilization. Biological analyses proved the biocompatibility of the sterilized membranes both in vitro and in a preliminary in vivo test. Overall, this study points out that this sterilization technique can be successfully employed to achieve an effective and safe sterilization of polysaccharidic membranes for surgical use. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Hysteroscopic Sterilization

    MedlinePlus

    ... sterilization? Sterilization is a permanent form of birth control. What is tubal sterilization? Sterilization procedures for women are ... is quicker than from other types of sterilization. What are the risks of ... on for birth control. • There is a risk of injury to the ...

  16. Surface characteristics of sterilized electropolished NiTi shape memory alloy as biomaterials

    NASA Astrophysics Data System (ADS)

    Tabrizian, Maryam; Thierry, Benjamin; Savadogo, Omarou; Yahia, L'Hocine

    1999-05-01

    As a potential biomaterial for many medical applications, NiTi alloy derives its good biocompatibility and corrosion resistance from a homogeneous and protective oxide layer, mainly composed of TiO2, with little concentration of nickel. However, during corrosion testing at high potential, NiTi is susceptible to pitting corrosion, which may affect the amount of ions (nickel and titanium) released by the alloy and thus, may affect its biocompatibility. As a passivating treatment, electropolishing (EP) was demonstrated to decrease the amount of nickel on the surface and to remarkably improve the corrosion behavior of the alloy. After sterilization by ethylene oxide (EO), no modification of the promising corrosion behavior of electropolished NiTi were observed, although some surface modifications were reported. The corrosion resistance of ethylene oxide sterilized and electropolished samples ranked between that of the commonly used Ti6A14V and 316L (0.4 less than 1 less than 1.4 mV/SCE) implant alloys.

  17. Sterilization by oxygen plasma

    NASA Astrophysics Data System (ADS)

    Moreira, Adir José; Mansano, Ronaldo Domingues; Andreoli Pinto, Terezinha de Jesus; Ruas, Ronaldo; Zambon, Luis da Silva; da Silva, Mônica Valero; Verdonck, Patrick Bernard

    2004-07-01

    The use of polymeric medical devices has stimulated the development of new sterilization methods. The traditional techniques rely on ethylene oxide, but there are many questions concerning the carcinogenic properties of the ethylene oxide residues adsorbed on the materials after processing. Another common technique is the gamma irradiation process, but it is costly, its safe operation requires an isolated site and it also affects the bulk properties of the polymers. The use of a gas plasma is an elegant alternative sterilization technique. The plasma promotes an efficient inactivation of the micro-organisms, minimises the damage to the materials and presents very little danger for personnel and the environment. Pure oxygen reactive ion etching type of plasmas were applied to inactivate a biologic indicator, the Bacillus stearothermophilus, to confirm the efficiency of this process. The sterilization processes took a short time, in a few minutes the mortality was complete. In situ analysis of the micro-organisms' inactivating time was possible using emission spectrophotometry. The increase in the intensity of the 777.5 nm oxygen line shows the end of the oxidation of the biologic materials. The results were also observed and corroborated by scanning electron microscopy.

  18. Hugoniot-measurements of room- and high-temperature metals for study of EOS and strength

    NASA Astrophysics Data System (ADS)

    Mashimo, Tsutomu; Gomoto, Yuya; Takashima, Hideyuki; Murai, Mitsuru; Yoshiasa, Akira

    2011-06-01

    Pressure calibration in static high-pressure experiments has been undertaken on the basis of the EOS derived from the Hugoniot compression curves of metals (Au, Pt, Cu, W, etc.), MgO, etc. To obtain the strict EOS at room- and high-temperatures, we need to precisely measure the Hugoniot data, and access the strength and Grüneisen parameter under shock compression. If the Hugoniot data of elevated temperature samples are measured, the high-temperature EOS can be accurately derived, and the Grüneisen parameter can be directly discussed. The strength might decrease at high temperature. The Hugoniot-measurement experiments have been performed on single crystal Au, oxygen-free Cu, forged Ta and W by a streak photographic system equipped with a powder gun and two-stage light gas gun in the pressure range up to >200 GPa. In addition, the Hugoniot-measurement experiment of the elevated temperature samples was started using high-frequency heating on W, Au, etc. Some of the results will be presented, and the EOS and strength are discussed.

  19. Starck Ta PTW strength model recommendation for use with SESAME 93524 EoS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sjue, Sky K.; Prime, Michael Bruce

    2017-02-27

    The purpose of this document is to provide a calibration of the Preston-Tonks- Wallace (PTW) strength model for use with the new SESAME equation of state (EoS) 93524. The calibration data included in this t spans temperatures from 198 K to 673 K and strain rates from 0.001/s to 3200/s.

  20. Atmospheric-pressure plasma decontamination/sterilization chamber

    DOEpatents

    Herrmann, Hans W.; Selwyn, Gary S.

    2001-01-01

    An atmospheric-pressure plasma decontamination/sterilization chamber is described. The apparatus is useful for decontaminating sensitive equipment and materials, such as electronics, optics and national treasures, which have been contaminated with chemical and/or biological warfare agents, such as anthrax, mustard blistering agent, VX nerve gas, and the like. There is currently no acceptable procedure for decontaminating such equipment. The apparatus may also be used for sterilization in the medical and food industries. Items to be decontaminated or sterilized are supported inside the chamber. Reactive gases containing atomic and metastable oxygen species are generated by an atmospheric-pressure plasma discharge in a He/O.sub.2 mixture and directed into the region of these items resulting in chemical reaction between the reactive species and organic substances. This reaction typically kills and/or neutralizes the contamination without damaging most equipment and materials. The plasma gases are recirculated through a closed-loop system to minimize the loss of helium and the possibility of escape of aerosolized harmful substances.

  1. The EducEO project

    NASA Astrophysics Data System (ADS)

    Fritz, Steffen; Dias, Eduardo; Zeug, Guenther; Vescovi, Fabio; See, Linda; Sturn, Tobias; McCallum, Ian; Stammes, Piet; Snik, Frans; Hendriks, Elise

    2015-04-01

    The ESA funded EducEO project is aimed at demonstrating the potential of citizen science and crowdsourcing for Earth Observation (EO), where citizen science and crowdsourcing refer to the involvement of citizens in tasks such as data collection. The potential for using citizens in the calibration and validation of satellite imagery through in-situ measurements and image recognition is largely untapped. The EducEO project will aim to achieve good integration with networks such as GLOBE (primary and secondary education) and COST (higher education) to involve students in four different applications that will be piloted as part of the EducEO project. The presentation will provide a brief overview and initial results of these applications, which include: the iSpex tool for measuring air pollution using an iPhone; a game to classify cropland and deforested areas from high resolution satellite imagery; an application to monitor areas of forest change using radar data from Sentinel-1; and the collection of in-situ yield and production data from both farmers (using high-tech farming equipment) and students. In particular initial results and future potential of the serious game on land cover and forest change monitoring will be discussed.

  2. The EOS Aura Mission

    NASA Technical Reports Server (NTRS)

    Schoeberl, Mark R.; Douglass, A. R.; Hilsenrath, E.; Luce, M.; Barnett, J.; Beer, R.; Waters, J.; Gille, J.; Levelt, P. F.; DeCola, P.; hide

    2001-01-01

    The EOS Aura Mission is designed to make comprehensive chemical measurements of the troposphere and stratosphere. In addition the mission will make measurements of important climate variables such as aerosols, and upper tropospheric water vapor and ozone. Aura will launch in late 2003 and will fly 15 minutes behind EOS Aqua in a polar sun synchronous ascending node orbit with a 1:30 pm equator crossing time.

  3. Laparoscopic female sterilization.

    PubMed

    Filshie, G M

    1989-09-01

    An overview of laparoscopic sterilization techniques from a historical and practical viewpoint includes instrumentation, operative techniques, mechanical occlusive devices, anesthesia, failure rates, morbidity and mortality. Laparoscope was first reported in 1893, but was developed simultaneously in France, Great Britain, Canada and the US in the 1960s. There are smaller laparoscopes for double-puncture procedures, and larger, single-puncture laparoscopes. To use a ring or clip, a much larger operating channel, up to 8 mm is needed. Insufflating gas may be CO2, which does not support combustion, but is more uncomfortable, NO2, which is also an anesthetic, and room air often used in developing countries. Unipolar electrocautery is now rarely used, in fact most third party payers do not allow it. Bipolar cautery, thermal coagulation and laser photocoagulation are safer methods. Falope rings, Hulka-Clemens, Filshie, Bleier, Weck and Tupla clips are described and illustrated. General anesthesia, usually a short acting agent with a muscle relaxant, causes 33% of the mortality of laparoscope, often due to cardiac arrest and arrhythmias, preventable with atropine. Local anesthesia is safer and cheaper and often used in developing countries. Failure rates of the various laparoscopic tubal sterilization methods are reviewed: most result from fistula formation. Mortality and morbidity can be caused by bowel damage, injury or infection, pre- existing pelvic infection, hemorrhage, gas embolism (avoidable by the saline drip test), and other rare events.

  4. EOS workstation

    NASA Technical Reports Server (NTRS)

    Leberl, Franz; Karspeck, Milan; Millot, Michel; Maurice, Kelly; Jackson, Matt

    1992-01-01

    This final report summarizes the work done from mid-1989 until January 1992 to develop a prototype set of tools for the analysis of EOS-type images. Such images are characterized by great multiplicity and quantity. A single 'snapshot' of EOS-type imagery may contain several hundred component images so that on a particular pixel, one finds multiple gray values. A prototype EOS-sensor, AVIRIS, has 224 gray values at each pixel. The work focused on the ability to utilize very large images and continuously roam through those images, zoom and be able to hold more than one black and white or color image, for example for stereo viewing or for image comparisons. A second focus was the utilization of so-called 'image cubes', where multiple images need to be co-registered and then jointly analyzed, viewed, and manipulated. The target computer platform that was selected was a high-performance graphics superworkstation, Stardent 3000. This particular platform offered many particular graphics tools such as the Application Visualization System (AVS) or Dore, but it missed availability of commercial third-party software for relational data bases, image processing, etc. The project was able to cope with these limitations and a phase-3 activity is currently being negotiated to port the software and enhance it for use with a novel graphics superworkstation to be introduced into the market in the Spring of 1993.

  5. Sterilization of medical equipment and contaminated articles by making use of a resistive barrier discharge

    NASA Astrophysics Data System (ADS)

    Uhm, Han S.; Kang, Jung G.; Choi, Eun H.; Cho, Guang S.

    2012-08-01

    Presented here is an apparatus consisting of an atmospheric resistive-barrier discharge for the sterilization of medical tools wrapped in typical hospital cloths, for the sterilization of manufactured drugs in typical packaging materials, and for the sterilization of biologically-contaminated articles. The sterilization apparatus consists of layers of the resistive-barrier discharge device operating at room temperature, a sterilization chamber, and an ozone destruction device. An electrical discharge in the resistive-barrier discharge system generates an atmospheric plasma in oxygen gas, generating ozone, which in turn efficiently sterilizes medical tools and biologically contaminated articles at room temperature. A sterilization experiment was carried out at an apparatus volume of 100 liters, with a sterilization chamber volume of 60 liters, and a discharge device volume of 40 liters. The sterilization in this experiment required 60 W of power for 5 hours of residence time. For a given sterilization time, the required electrical power was proportional to the apparatus volume. Ozone in the sterilization chamber was destroyed safely after sterilization.

  6. Interval Female Sterilization.

    PubMed

    Stuart, Gretchen S; Ramesh, Shanthi S

    2018-01-01

    Female sterilization is relied on by nearly one in three women aged 35-44 years in the United States. Sterilization procedures are among the most common procedures that obstetrician-gynecologists perform. The most frequent sterilization procedures include postpartum tubal ligation, laparoscopic tubal disruption or salpingectomy, and hysteroscopic tubal occlusion. The informed consent process for sterilization is crucial and requires shared decision-making between the patient and the health care provider. Counseling should include the specific risks and benefits of the specific surgical approaches. Additionally, women should be counseled on the alternatives to sterilization, including intrauterine contraceptives and subdermal contraceptive implants. Complications, including unplanned pregnancy after successful female sterilization, are rare. The objectives of this Clinical Expert Series are to describe the epidemiology of female sterilization, access to postpartum sterilization, advances in interval sterilization techniques, and clinical considerations in caring for women requesting sterilization.

  7. Simultaneous Sterilization With Surface Modification Of Plastic Bottle By Plasma-Based Ion Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakudo, N.; Ikenaga, N.; Ikeda, F.

    2011-01-07

    Dry sterilization of polymeric material is developed. The technique utilizes the plasma-based ion implantation which is same as for surface modification of polymers. Experimental data for sterilization are obtained by using spores of Bacillus subtilis as samples. On the other hand we previously showed that the surface modification enhanced the gas barrier characteristics of plastic bottles. Comparing the implantation conditions for the sterilization experiment with those for the surface modification, we find that both sterilization and surface modification are simultaneously performed in a certain range of implantation conditions. This implies that the present bottling system for plastic vessels will bemore » simplified and streamlined by excluding the toxic peroxide water that has been used in the traditional sterilization processes.« less

  8. Comparison of low-temperature hydrogen peroxide gas plasma sterilization for endoscopes using various Sterrad models.

    PubMed

    Okpara-Hofmann, J; Knoll, M; Dürr, M; Schmitt, B; Borneff-Lipp, M

    2005-04-01

    This study compared the effectiveness of sterilizing four types of endoscope using different models of the Sterrad system (Sterrad 50, 100, 100S and 200). Sterilization levels meeting international requirements were attained in all cases with carriers inoculated with Geobacillus stearothermophilus spores. The endoscopes were tested in half cycles ('overkill'). This is the first study to compare the Sterrad models marketed to date in terms of effective sterilization of endoscopes with narrow lumens.

  9. Mands for Information Using "How" Under EO-Absent and EO-Present Conditions.

    PubMed

    Shillingsburg, M Alice; Bowen, Crystal N; Valentino, Amber L

    2014-06-01

    The present study replicates and extends previous research on teaching "How?" mands for information to children with autism. The experimental preparation involved mand training in the context of completing preferred activities and included training and testing under conditions when the establishing operation (EO) was present and absent. Results show that two children with autism acquired mands for information using How? only in situations where information was valuable (i.e., the EO was present); they then consistently made use of the information provided in activity completion. Generalization to novel, untaught situations was assessed.

  10. Lakshmi joins Eos Team

    NASA Astrophysics Data System (ADS)

    Grant, Shermonta L.

    Venkat Lakshmi, an assistant professor in the Department of Geological Sciences at the University of South Carolina, has begun his 3-year term with Eos as the hydrology section editor. Among his goals as editor, Lakshmi will seek to portray hydrology as an integrative science. “Hydrology is not a stand-alone science,” he said. “I will encourage interdisciplinary articles in Eos that deal with water issues and the role of hydrology within a broad spectrum of problems and disciplines.”

  11. Sizing the science data processing requirements for EOS

    NASA Technical Reports Server (NTRS)

    Wharton, Stephen W.; Chang, Hyo D.; Krupp, Brian; Lu, Yun-Chi

    1991-01-01

    The methodology used in the compilation and synthesis of baseline science requirements associated with the 30 + EOS (Earth Observing System) instruments and over 2,400 EOS data products (both output and required input) proposed by EOS investigators is discussed. A brief background on EOS and the EOS Data and Information System (EOSDIS) is presented, and the approach is outlined in terms of a multilayer model. The methodology used to compile, synthesize, and tabulate requirements within the model is described. The principal benefit of this approach is the reduction of effort needed to update the analysis and maintain the accuracy of the science data processing requirements in response to changes in EOS platforms, instruments, data products, processing center allocations, or other model input parameters. The spreadsheets used in the model provide a compact representation, thereby facilitating review and presentation of the information content.

  12. Investigation of a sterilization system using active oxygen species generated by ultraviolet irradiation.

    PubMed

    Yoshino, Kiyoshi; Matsumoto, Hiroyuki; Iwasaki, Tatsuyuki; Kinoshita, Shinobu; Noda, Kazutoshi; Oya, Kei; Iwamori, Satoru

    2015-01-01

    We have been investigating an advanced sterilization system that employs active oxygen species (AOS). We designed the sterilization equipment, including an evacuation system, which generates AOS from pure oxygen gas using ultraviolet irradiation, in order to study the conditions necessary for sterilization in the system's chamber. Using Geobachillus stearothermophilus spores (10(6) CFU) in a sterile bag as a biological indicator (BI) in the chamber of the AOS sterilization apparatus, we examined the viability of the BI as a function of exposure time, assessing the role of the decompression level in the sterilization performance. We found that the survival curves showed exponential reduction, and that the decompression level did not exert a significant influence on the survival curve. Subsequently, we investigated the sterilization effect as influenced by the spatial and environmental temperature variation throughout the chamber, and found that the sterilization effect varied with position, due to the varying environmental temperature in the respective areas. We confirmed that temperature is one of the most important factors influencing sterilization in the chamber, and estimated the temperature effect on the distribution of atomic oxygen concentration, using the quartz crystal microbalance (QCM) method with fluorocarbon thin film prepared by radio frequency sputtering.

  13. Ethylene oxide sterilization: how hospitals can adapt to the changes.

    PubMed

    1994-12-01

    Ethylene oxide (EtO) gas sterilizers have been used by hospitals for over 40 years to sterilize surgical equipment and supplies that are heat sensitive or that cannot tolerate excessive moisture. However, in recent decades, EtO has been recognized as a potential mutagenic, reproductive, neurologic, and fire and explosion hazard to workers, and one agency has reportedly voted to classify EtO as carcinogenic to humans. Strict regulations concerning EtO exposure have been imposed by the Occupational Safety and Health Administration (OSHA), and the use of EtO, along with other toxic pollutants, is also being monitored by the Environmental Protection Agency (EPA) under the Clean Air Act. In addition, the use of chlorofluorocarbons (CFCs) as EtO diluents has focused attention on the EtO-CFC mixtures used in many sterilizers because CFCs have been linked to destruction of the ozone layer. Concerns about restrictive regulations related to these issues have prompted many hospitals to examine their use of EtO sterilization and propagated the misinformation that EtO sterilization is being phased out. In this article, we address some commonly asked questions regarding the use and regulation of EtO mixtures, as well as alternative sterilization agents and methods; provide two case studies illustrating how hospitals can evaluate various sterilization options; and summarize our conclusions and recommendations for hospitals facing decisions about sterilization techniques. For related topics, also see our Evaluation Update on endoscope reprocessors and our Hazard Report on improperly connected EtO-CFC cylinders to EtO sterilizers in this issue.

  14. Simultaneous treatment of washing, disinfection and sterilization using ultrasonic levitation, silver electrolysis and ozone oxidation.

    PubMed

    Ueda, Toyotoshi; Hara, Masanori; Odagawa, Ikumi; Shigihara, Takanori

    2009-03-01

    A new type of ultrasonic washer-disinfector-sterilizer, able to clean, disinfect and sterilize most kinds of reusable medical devices, has been developed by using the ultrasonic levitation function with umbrella-shape oscillators and ozone bubbling together with sterilization carried out by silver electrolysis. We have examined the biomedical and physicochemical performance of this instrument. Prokariotic and gram-negative Escherichia coli and eukariotic Saccharomyces cerevisiae were killed by silver electrolysis in 18 min and 1 min, respectively. Prokariotic and gram-positive Geobacillus stearothermophilus and Bacillus atrophaeus, which are most resistant to autoclave and gas sterilization, respectively, were killed by silver electrolysis within 20 min. Prokariotic and gram-negative Pseudomonas aeruginosa was also killed by silver electrolysis in 10 min. The intensity distribution of the ultrasonic levitation waves was homogeneous throughout the tank. The concentration of ozone gas was 2.57 mg/ kg. The concentration of dissolved silver ions was around 0.17 mg/L. The disulfide bond in proteins was confirmed to be destroyed by silver electrolysis.

  15. [Comparative study of the effects of sterilized air and perfluoropropane gas tamponades on recovery after idiopathic full-thickness macular hole surgery].

    PubMed

    He, F; Zheng, L; Dong, F T

    2017-05-11

    Objective: To compare the effects of sterilized air and perfluoropropane (C(3)F(8)) tamponades on recovery after vitrectomy for the treatment of idiopathic full-thickness macular hole (IFTMH). Methods: Case control study. Seventy-three eyes of 69 consecutive cases underwent vitrectomy with air (53 eyes) or 10% C(3)F(8) gas (20 eyes) tamponade. Surgical outcomes were retrospectively analyzed between the two groups, including logarithm of the minimal angle of resolution (logMAR) and optical coherence tomography findings like the size of the macular hole and the photoreceptor layer defect. Results: Preoperatively, the mean best corrected visual acuity (BCVA) was (0.10±0.49), the mean hole diameter was (777.9±320.7) μm, and the mean diameter of the photoreceptor layer defect was (1 709.3±516.0) μm in the sterilized air group, while in the C(3)F(8) group, the mean BCVA was (0.07±0.50), the mean hole diameter was (853.9±355.0) μm, and the mean defect diameter was (1 480.5±429.9) μm. The primary closure rate was 90.6% in the sterilized air group and 95.0% in the C(3)F(8) group. One month after surgery, the mean BCVA was (0.17±0.41), and the mean diameter of the photoreceptor layer defect was (820.5±598.0) μm in the sterilized air group, while in the C(3)F(8) group, the mean BCVA was 0.12±0.49, and the mean defect diameter was (762.5±658.0) μm. There was no statistically significant difference in the closure rate (χ(2)=0.019), BCVA ( t =-1.689), hole diameter ( t =0.837) and diameter of the photoreceptor layer defect ( t =0.338) between the two groups( P >0.05). Conclusions: Vitrectomy with sterilized air tamponade is safe and effective for the treatment of IFTMH and even cases with relatively large diameters. (Chin J Ophthalmol, 2017, 53: 327 - 331) .

  16. Sterilization by pure oxygen plasma and by oxygen-hydrogen peroxide plasma: an efficacy study.

    PubMed

    Boscariol, M R; Moreira, A J; Mansano, R D; Kikuchi, I S; Pinto, T J A

    2008-04-02

    Plasma is an innovative sterilization method characterized by a low toxicity to operators and patients, and also by its operation at temperatures close to room temperatures. The use of different parameters for this method of sterilization and the corresponding results were analyzed in this study. A low-pressure inductive discharge was used to study the plasma sterilization processes. Oxygen and a mixture of oxygen and hydrogen peroxide were used as plasma source gases. The efficacy of the processes using different combinations of parameters such as plasma-generation method, type of gas, pressure, gas flow rate, temperature, power, and exposure time was evaluated. Two phases were developed for the processes, one using pure oxygen and the other a mixture of gases. Bacillus subtilis var. niger ATCC 9372 (Bacillus atrophaeus) spores inoculated on glass coverslips were used as biological indicators to evaluate the efficacy of the processes. All cycles were carried out in triplicate for different sublethal exposure times to calculate the D value by the enumeration method. The pour-plate technique was used to quantify the spores. D values of between 8 and 3 min were obtained. Best results were achieved at high power levels (350 and 400 W) using pure oxygen, showing that plasma sterilization is a promising alternative to other sterilization methods.

  17. Yarkovsky footprints in the Eos family

    NASA Astrophysics Data System (ADS)

    Vokrouhlický, D.; Brož, M.; Morbidelli, A.; Bottke, W. F.; Nesvorný, D.; Lazzaro, D.; Rivkin, A. S.

    2006-05-01

    The Eos asteroid family is the third most populous, after Themis and Koronis, and one of the largest non-random groups of asteroids in the main belt. It has been known and studied for decades, but its structure and history still presented difficulties to understand. We first revise the Eos family identification as a statistical cluster in the space of proper elements. Using the most to-date catalogue of proper elements we determine a nominal Eos family, defined by us using the hierarchical-clustering method with the cut-off velocity of 55 m/s, contains some 4400 members. This unforeseen increase in known Eos asteroids allows us to perform a much more detailed study than was possible so far. We show, in particular, that most of the previously thought peculiar features are explained within the following model: (i) collisional disruption of the parent body leads to formation of a compact family in the proper element space (with characteristic escape velocities of the observed asteroids of tens of meters per second, compatible with hydrocode simulations), and (ii) as time goes, the family dynamically evolves due to a combination of the thermal effects and planetary perturbations. This model allows us to explain sharp termination of the family at the J7/3 mean motion resonance with Jupiter, uneven distribution of family members about the J9/4 mean motion resonance with Jupiter, semimajor axis distribution of large vs small members in the family and anomalous residence of Eos members inside the high-order secular resonance z. Our dynamical method also allows us to estimate Eos family age to 1.3-0.2+0.15 Gyr. Several formal members of the Eos family are in conflict with our model and these are suspected interlopers. We use spectroscopic observations, whose results are also reported here, and results of 5-color wide-band Sloan Digital Sky Survey photometry to prove some of them are indeed spectrally incompatible with the family.

  18. Sterilization System

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Cox Sterile Products, Inc.'s Rapid Heat Transfer Sterilizer employs a heat exchange process that induces rapid air movement; the air becomes the heat transfer medium, maintaining a uniform temperature of 375 degrees Fahrenheit. It features pushbutton controls for three timing cycles for different instrument loads, a six-minute cycle for standard unpackaged instruments, eight minutes for certain specialized dental/medical instruments and 12 minutes for packaged instruments which can then be stored in a drawer in sterile condition. System will stay at 375 degrees all day. Continuous operation is not expensive because of the sterilizer's very low power requirements.

  19. Lidar instruments proposed for Eos

    NASA Technical Reports Server (NTRS)

    Grant, William B.; Browell, Edward V.

    1990-01-01

    Lidar, an acronym for light detection and ranging, represents a class of instruments that utilize lasers to send probe beams into the atmosphere or onto the surface of the Earth and detect the backscattered return in order to measure properties of the atmosphere or surface. The associated technology has matured to the point where two lidar facilities, Geodynamics Laser Ranging System (GLRS), and Laser Atmospheric Wind Sensor (LAWS) were accepted for Phase 2 studies for Eos. A third lidar facility Laser Atmospheric Sounder and Altimeter (LASA), with the lidar experiment EAGLE (Eos Atmospheric Global Lidar Experiment) was proposed for Eos. The generic lidar system has a number of components. They include controlling electronics, laser transmitters, collimating optics, a receiving telescope, spectral filters, detectors, signal chain electronics, and a data system. Lidar systems that measure atmospheric constituents or meteorological parameters record the signal versus time as the beam propagates through the atmosphere. The backscatter arises from molecular (Rayleigh) and aerosol (Mie) scattering, while attenuation arises from molecular and aerosol scattering and absorption. Lidar systems that measure distance to the Earth's surface or retroreflectors in a ranging mode record signals with high temporal resolution over a short time period. The overall characteristics and measurements objectives of the three lidar systems proposed for Eos are given.

  20. Building EOS capability for Malaysia - the options

    NASA Astrophysics Data System (ADS)

    Subari, M. D.; Hassan, A.

    2014-06-01

    Earth observation satellite (EOS) is currently a major tool to monitor earth dynamics and increase human understanding of earth surface process. Since the early 80s, Malaysia has been using EOS images for various applications, such as weather forecasting, land use mapping, agriculture, environment monitoring and others. Until now, all EOS images were obtained from foreign satellite systems. Realising on the strategic need of having its own capability, Malaysia embarked into EOS development programs in the early 90s. Starting with TiungSAT-1, a micro-satellite carrying small camera, then followed by RazakSAT, a small satellite carrying 2.5 m panchromatic (PAN) medium-aperture-camera, the current satellite program development, the RazakSAT-2, designed to carry a 1.0 m high resolution PAN and 4.0m multi-spectral camera, would become a strategic initiative of the government in developing and accelerating the nation's capability in the area of satellite technology and its application. Would this effort continue until all needs of the remote sensing community being fulfilled by its own EOS? This paper will analyze the intention of the Malaysian government through its National Space Policy and other related policy documents, and proposes some policy options on this. Key factors to be considered are specific data need of the EOS community, data availability and the more subjective political motivations such as national pride.

  1. [Sterilization effect analysis of B-class pulsation table top vacuum sterilizer to dental handpieces].

    PubMed

    Zeng, Shu-Rong; Jiang, Bo; Xiao, Xiao-Rong

    2007-06-01

    Discuss sterilization effect of B-class pulsation table top vacuum pressure steam sterilizer for dental handpiece. Analysis selection of sterilizer for dental handpiece and sterilization management processes and sterilization effect monitoring, evaluation of monitoring result and effective sterilization method. The B-class pulsation table top vacuum pressure steam sterilizer to dental handpiece in West China Stomatological Hospital of Sichuan University met the requirement of the chemical and biological monitoring. Its efficiency of sterilization was 100%. The results of aerobic culture, anaerobic culture, B-type hepatitis mark monitoring to sterilized dental handpiece were negative. It is effective method for dental handpiece sterilization to use B-class pulsation table top vacuum pressure steam sterilizer.

  2. Converting from XML to HDF-EOS

    NASA Technical Reports Server (NTRS)

    Ullman, Richard; Bane, Bob; Yang, Jingli

    2008-01-01

    A computer program recreates an HDF-EOS file from an Extensible Markup Language (XML) representation of the contents of that file. This program is one of two programs written to enable testing of the schemas described in the immediately preceding article to determine whether the schemas capture all details of HDF-EOS files.

  3. ISO radiation sterilization standards

    NASA Astrophysics Data System (ADS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-06-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, "Radiation Sterilization Material Qualification" 2. ISO TR 13409-1996, "Sterilization of health care products — Radiation sterilization — Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches" 3. ISO Draft TR, "Sterilization of health care products — Radiation sterilization Selection of a sterilization dose for a single production batch" li]4. ISO Draft TR, "Sterilization of health care products — Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits."

  4. EO-1 Prototyping for Environmental Applications

    NASA Astrophysics Data System (ADS)

    Campbell, P. K.; Middleton, E.; Ungar, S.; Zhang, Q.; Ong, L.; Huemmrich, K. F.

    2009-12-01

    The Earth Observing One (EO-1) Mission, launched in November, 2000 as part of NASA’s New Millennium Program, is in it’s eight year of operation. From the start it was recognized that a key criteria for evaluating the EO-1 technology and outlining future Earth science mission needs is the ability of the technology to characterize terrestrial surface state and processes. EO-1 is participating in a broad range of investigations, demonstrating the utility of imaging spectroscopy in applications relating to forestry, agriculture, species discrimination, invasive species, desertification, land-use, vulcanization, fire management, homeland security, natural and anthropogenic hazards and disaster assessments and has provided characterization for a variety of instruments on EOS platforms. By generating a high spectral and spatial resolution data set for the corral reefs and islands, it is contributing for realizing the goals of the National Decadal survey and providing an excellent platform for testing strategies to be employed in the HyspIRI mission. The EO1 Mission Science Office (MSO) is developing tools and prototypes for new science products, addressing the HyspIRI goals to assess vegetation status and health and provide vegetation spectral bio-indicators and biophysical parameters such as LAI and fAPAR at <100 m spatial resolution. These are being used to resolve variability in heterogeneous areas (e.g. agriculture, narrow shapes, urban and developed lands) and for managed ecosystems less than 10 km2. A set of invariable reference targets (e.g. sun, moon, deserts, Antarctica) are being characterised to allow cross-calibration of current and future EO sensors, comparison of land products generated by multiple sensors and retroactive processing of time series data. Such products are needed to develop Science Requirements for the next generation of hyperspectral satellite sensors and to address global societal needs.

  5. EO Information Center - Naval Oceanography Portal

    Science.gov Websites

    are here: Home › USNO › Earth Orientation › EO Information Center USNO Logo USNO Navigation Earth Orientation Products GPS-based Products VLBI-based Products EO Information Center General Information GPS User Information Frequently Asked Questions Read Me Files Publications about Products Software

  6. Sterilization of endoscopic instruments.

    PubMed

    Sabnis, Ravindra B; Bhattu, Amit; Vijaykumar, Mohankumar

    2014-03-01

    Sterilization of endoscopic instruments is an important but often ignored topic. The purpose of this article is to review the current literature on the sterilization of endoscopic instruments and elaborate on the appropriate sterilization practices. Autoclaving is an economic and excellent method of sterilizing the instruments that are not heat sensitive. Heat sensitive instruments may get damaged with hot sterilization methods. Several new endoscopic instruments such as flexible ureteroscopes, chip on tip endoscopes, are added in urologists armamentarium. Many of these instruments are heat sensitive and hence alternative efficacious methods of sterilization are necessary. Although ethylene oxide and hydrogen peroxide are excellent methods of sterilization, they have some drawbacks. Gamma irradiation is mainly for disposable items. Various chemical agents are widely used even though they achieve high-level disinfection rather than sterilization. This article reviews various methods of endoscopic instrument sterilization with their advantages and drawbacks. If appropriate sterilization methods are adopted, then it not only will protect patients from procedure-related infections but prevent hypersensitive allergic reactions. It will also protect instruments from damage and increase its longevity.

  7. Sterilization of bacterial endospores by an atmospheric-pressure argon plasma jet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uhm, Han S.; Lim, Jin P.; Li, Shou Z.

    2007-06-25

    Argon plasma jets penetrate deep into ambient air and create a path for oxygen radicals to sterilize microbes. A sterilization experiment with bacterial endospores indicates that an argon-oxygen plasma jet very effectively kills endospores of Bacillus atrophaeus (ATCC 9372), thereby demonstrating its capability to clean surfaces and its usefulness for reinstating contaminated equipment as free from toxic biological warfare agents. However, the spore-killing efficiency of the atmospheric-pressure argon-oxygen jet depends very sensitively on the oxygen concentration in the argon gas.

  8. Sterilization of Exopolysaccharides Produced by Deep-Sea Bacteria: Impact on Their Stability and Degradation

    PubMed Central

    Rederstorff, Emilie; Fatimi, Ahmed; Sinquin, Corinne; Ratiskol, Jacqueline; Merceron, Christophe; Vinatier, Claire; Weiss, Pierre; Colliec-Jouault, Sylvia

    2011-01-01

    Polysaccharides are highly heat-sensitive macromolecules, so high temperature treatments are greatly destructive and cause considerable damage, such as a great decrease in both viscosity and molecular weight of the polymer. The technical feasibility of the production of exopolysaccharides by deep-sea bacteria Vibrio diabolicus and Alteromonas infernus was previously demonstrated using a bioproduct manufacturing process. The objective of this study was to determine which sterilization method, other than heat sterilization, was the most appropriate for these marine exopolysaccharides and was in accordance with bioprocess engineering requirements. Chemical sterilization using low-temperature ethylene oxide and a mixture of ionized gases (plasmas) was compared to the sterilization methods using gamma and beta radiations. The changes to both the physical and chemical properties of the sterilized exopolysaccharides were analyzed. The use of ethylene oxide can be recommended for the sterilization of polysaccharides as a weak effect on both rheological and structural properties was observed. This low-temperature gas sterilizing process is very efficient, giving a good Sterility Assurance Level (SAL), and is also well suited to large-scale compound manufacturing in the pharmaceutical industry. PMID:21566796

  9. Ozone-mist spray sterilization for pest control in agricultural management

    NASA Astrophysics Data System (ADS)

    Ebihara, Kenji; Mitsugi, Fumiaki; Ikegami, Tomoaki; Nakamura, Norihito; Hashimoto, Yukio; Yamashita, Yoshitaka; Baba, Seiji; Stryczewska, Henryka D.; Pawlat, Joanna; Teii, Shinriki; Sung, Ta-Lun

    2013-02-01

    We developed a portable ozone-mist sterilization system to exterminate pests (harmful insects) in agricultural field and greenhouse. The system is composed of an ozone generator, an ozone-mist spray and a small container of ozone gas. The ozone generator can supply highly concentrated ozone using the surface dielectric barrier discharge. Ozone-mist is produced using a developed nozzle system. We studied the effects of ozone-mist spray sterilization on insects and agricultural plants. The sterilization conditions are estimated by monitoring the behavior of aphids and observing the damage of the plants. It was shown that aphids were exterminated in 30 s without noticeable damages of the plant leaves. The reactive radicals with strong oxidation potential such as hydroxyl radical (*OH), hydroperoxide radical (*HO2), the superoxide ion radical (*O2‒) and ozonide radical ion (*O3‒) can increase the sterilization rate for aphids. Contribution to the Topical Issue "13th International Symposium on High Pressure Low Temperature Plasma Chemistry (Hakone XIII)", Edited by Nicolas Gherardi, Henryca Danuta Stryczewska and Yvan Ségui.

  10. [Principles of antisepsis, disinfection and sterilization].

    PubMed

    Hernández-Navarrete, María-Jesús; Celorrio-Pascual, José-Miguel; Lapresta Moros, Carlos; Solano Bernad, Victor-Manuel

    2014-12-01

    This article aims to provide a brief review of the main concepts on which the prevention and control of infection are based. Antisepsis comprises a set of techniques aimed at the total sterilization, or at most, disinfection, removing germs that contaminate an environment. Both procedures must be preceded by an environmental cleanup in the location in which they intend to be applied. The disinfection is carried out using biocides or germicides. Antimicrobial chemicals, that have mechanisms of action and resistances very similar to antibiotics, are generating concern due to the possibility of crossing genetic information that aggravates the problem of bacterial resistance. Most biocides can act as antiseptics, and applied to skin tissue, or disinfectants on inanimate materials. The spectrum of action of germicides depends on the product itself and external controllable factors: temperature, concentration, exposure time, etc. Sterilization techniques are primarily physical, by exposing the material to steam, or sterilizing gas, using autoclaves. Major advances are the use of low temperatures with shorter exposure times, in parallel with technological advances in instrumentation in order to avoid high temperatures and high use rotations due to workload. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  11. The Noble-Abel Stiffened-Gas equation of state

    NASA Astrophysics Data System (ADS)

    Le Métayer, Olivier; Saurel, Richard

    2016-04-01

    Hyperbolic two-phase flow models have shown excellent ability for the resolution of a wide range of applications ranging from interfacial flows to fluid mixtures with several velocities. These models account for waves propagation (acoustic and convective) and consist in hyperbolic systems of partial differential equations. In this context, each phase is compressible and needs an appropriate convex equation of state (EOS). The EOS must be simple enough for intensive computations as well as boundary conditions treatment. It must also be accurate, this being challenging with respect to simplicity. In the present approach, each fluid is governed by a novel EOS named "Noble Abel stiffened gas," this formulation being a significant improvement of the popular "Stiffened Gas (SG)" EOS. It is a combination of the so-called "Noble-Abel" and "stiffened gas" equations of state that adds repulsive effects to the SG formulation. The determination of the various thermodynamic functions and associated coefficients is the aim of this article. We first use thermodynamic considerations to determine the different state functions such as the specific internal energy, enthalpy, and entropy. Then we propose to determine the associated coefficients for a liquid in the presence of its vapor. The EOS parameters are determined from experimental saturation curves. Some examples of liquid-vapor fluids are examined and associated parameters are computed with the help of the present method. Comparisons between analytical and experimental saturation curves show very good agreement for wide ranges of temperature for both liquid and vapor.

  12. Global EOS: exploring the 300-ms-latency region

    NASA Astrophysics Data System (ADS)

    Mascetti, L.; Jericho, D.; Hsu, C.-Y.

    2017-10-01

    EOS, the CERN open-source distributed disk storage system, provides the highperformance storage solution for HEP analysis and the back-end for various work-flows. Recently EOS became the back-end of CERNBox, the cloud synchronisation service for CERN users. EOS can be used to take advantage of wide-area distributed installations: for the last few years CERN EOS uses a common deployment across two computer centres (Geneva-Meyrin and Budapest-Wigner) about 1,000 km apart (∼20-ms latency) with about 200 PB of disk (JBOD). In late 2015, the CERN-IT Storage group and AARNET (Australia) set-up a challenging R&D project: a single EOS instance between CERN and AARNET with more than 300ms latency (16,500 km apart). This paper will report about the success in deploy and run a distributed storage system between Europe (Geneva, Budapest), Australia (Melbourne) and later in Asia (ASGC Taipei), allowing different type of data placement and data access across these four sites.

  13. Low temperature gamma sterilization of a bioresorbable polymer, PLGA

    NASA Astrophysics Data System (ADS)

    Davison, Lisa; Themistou, Efrosyni; Buchanan, Fraser; Cunningham, Eoin

    2018-02-01

    Medical devices destined for insertion into the body must be sterilised before implantation to prevent infection or other complications. Emerging biomaterials, for example bioresorbable polymers, can experience changes in their properties due to standard industrial sterilization processes. Gamma irradiation is one of the most reliable, large scale sterilization methods, however it can induce chain scission, cross-linking or oxidation reactions in polymers. sterilization at low temperature or in an inert atmosphere has been reported to reduce the negative effects of gamma irradiation. The aim of this study was to investigate the impact of low temperature sterilization (at -80 °C) when compared to sterilization at ambient temperature (25 °C) both in inert atmospheric conditions of nitrogen gas, on poly(lactide co-glycolide) (PLGA). PLGA was irradiated at -80 and 25 °C at 40 kGy in a nitrogen atmosphere. Samples were characterised using differential scanning calorimetry (DSC), tensile test, Fourier transform infrared (FTIR) spectroscopy, proton nuclear magnetic resonance (1H NMR) spectroscopy and gel permeation chromatography (GPC). The results showed that the molecular weight was significantly reduced as was the glass transition temperature, an indication of chain scission. FTIR showed small changes in chemical structure in the methyl and carbonyl groups after irradiation. Glass transition temperature was significantly different between irradiation at -80 °C and irradiation at 25 °C, however this was a difference of only 1 °C. Ultimately, the results indicate that the sterilization temperature used does not affect PLGA when carried out in a nitrogen atmosphere.

  14. Lumen claims of the STERRAD 100NX sterilizer: testing performance limits when processing equipment containing long, narrow lumens.

    PubMed

    Diab-Elschahawi, Magda; Blacky, Alexander; Bachhofner, Nicole; Koller, Walter

    2011-11-01

    According to manufacturers information, the STERRAD 100NX sterilizer-a low temperature H(2)O(2) gas plasma sterilizer-can adequately process single channel stainless steel lumens with an inside diameter of 0.7 mm or larger and a maximum length of 500 mm using standard cycle sterilizing conditions. The aim of this study was to qualify the performance of this H(2)O(2) gas plasma sterilizer under different experimental settings representing worst case conditions. Inoculated carriers were placed at the midpoint position of specified lumens and then submitted to flex scope sterilizing conditions. To simulate insufficient cleaning or crystalline residues, we added organic and inorganic challenges to our inoculated carriers. For experiments done with unchallenged carriers, quantitative analysis reached a log(10) reduction rate of ≥5.71, whereas qualitative results showed no growth in 24 out of 30 biologic indicators tested using flex scope half cycle conditions. Any additional kind of challenge significantly impaired the sterilization outcome. The findings of our current study emphasize the importance of a thorough validated cleaning of medical devices as well as timing for cleaning and decontamination before being exposed to the H(2)O(2) sterilization process and, furthermore, the need for strict adherence to manufacturer's recommendations. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  15. Probability of pregnancy after sterilization: a comparison of hysteroscopic versus laparoscopic sterilization.

    PubMed

    Gariepy, Aileen M; Creinin, Mitchell D; Smith, Kenneth J; Xu, Xiao

    2014-08-01

    To compare the expected probability of pregnancy after hysteroscopic versus laparoscopic sterilization based on available data using decision analysis. We developed an evidence-based Markov model to estimate the probability of pregnancy over 10 years after three different female sterilization procedures: hysteroscopic, laparoscopic silicone rubber band application and laparoscopic bipolar coagulation. Parameter estimates for procedure success, probability of completing follow-up testing and risk of pregnancy after different sterilization procedures were obtained from published sources. In the base case analysis at all points in time after the sterilization procedure, the initial and cumulative risk of pregnancy after sterilization is higher in women opting for hysteroscopic than either laparoscopic band or bipolar sterilization. The expected pregnancy rates per 1000 women at 1 year are 57, 7 and 3 for hysteroscopic sterilization, laparoscopic silicone rubber band application and laparoscopic bipolar coagulation, respectively. At 10 years, the cumulative pregnancy rates per 1000 women are 96, 24 and 30, respectively. Sensitivity analyses suggest that the three procedures would have an equivalent pregnancy risk of approximately 80 per 1000 women at 10 years if the probability of successful laparoscopic (band or bipolar) sterilization drops below 90% and successful coil placement on first hysteroscopic attempt increases to 98% or if the probability of undergoing a hysterosalpingogram increases to 100%. Based on available data, the expected population risk of pregnancy is higher after hysteroscopic than laparoscopic sterilization. Consistent with existing contraceptive classification, future characterization of hysteroscopic sterilization should distinguish "perfect" and "typical" use failure rates. Pregnancy probability at 1 year and over 10 years is expected to be higher in women having hysteroscopic as compared to laparoscopic sterilization. Copyright © 2014

  16. Identification of terpenes and essential oils by means of static headspace gas chromatography-ion mobility spectrometry.

    PubMed

    Rodríguez-Maecker, Roman; Vyhmeister, Eduardo; Meisen, Stefan; Rosales Martinez, Antonio; Kuklya, Andriy; Telgheder, Ursula

    2017-11-01

    Static headspace gas chromatography-ion mobility spectrometry (SHS GC-IMS) is a relatively new analytical technique that has considerable potential for analysis of volatile organic compounds (VOCs). In this study, SHS GC-IMS was used for the identification of the major terpene components of various essential oils (EOs). Based on the data obtained from 25 terpene standards and 50 EOs, a database for fingerprint identification of characteristic terpenes and EOs was generated utilizing SHS GC-IMS for authenticity testing of fragrances in foods, cosmetics, and personal care products. This database contains specific normalized IMS drift times and GC retention indices for 50 terpene components of EOs. Initially, the SHS GC-IMS parameters, e.g., drift gas and carrier gas flow rates, drift tube, and column temperatures, were evaluated to determine suitable operating conditions for terpene separation and identification. Gas chromatography-mass spectrometry (GC-MS) was used as a reference method for the identification of terpenes in EOs. The fingerprint pattern based on the normalized IMS drift times and retention indices of 50 terpenes is presented for 50 EOs. The applicability of the method was proven on examples of ten commercially available food, cosmetic, and personal care product samples. The results confirm the suitability of SHS GC-IMS as a powerful analytical technique for direct identification of terpene components in solid and liquid samples without any pretreatment. Graphical abstract Fingerprint pattern identification of terpenes and essential oils using static headspace gas chromatography-ion mobility spectrometry.

  17. Atomistic modeling of structure II gas hydrate mechanics: Compressibility and equations of state

    NASA Astrophysics Data System (ADS)

    Vlasic, Thomas M.; Servio, Phillip; Rey, Alejandro D.

    2016-08-01

    This work uses density functional theory (DFT) to investigate the poorly characterized structure II gas hydrates, for various guests (empty, propane, butane, ethane-methane, propane-methane), at the atomistic scale to determine key structure and mechanical properties such as equilibrium lattice volume and bulk modulus. Several equations of state (EOS) for solids (Murnaghan, Birch-Murnaghan, Vinet, Liu) were fitted to energy-volume curves resulting from structure optimization simulations. These EOS, which can be used to characterize the compressional behaviour of gas hydrates, were evaluated in terms of their robustness. The three-parameter Vinet EOS was found to perform just as well if not better than the four-parameter Liu EOS, over the pressure range in this study. As expected, the Murnaghan EOS proved to be the least robust. Furthermore, the equilibrium lattice volumes were found to increase with guest size, with double-guest hydrates showing a larger increase than single-guest hydrates, which has significant implications for the widely used van der Waals and Platteeuw thermodynamic model for gas hydrates. Also, hydrogen bonds prove to be the most likely factor contributing to the resistance of gas hydrates to compression; bulk modulus was found to increase linearly with hydrogen bond density, resulting in a relationship that could be used predictively to determine the bulk modulus of various structure II gas hydrates. Taken together, these results fill a long existing gap in the material chemical physics of these important clathrates.

  18. Atomistic modeling of structure II gas hydrate mechanics: Compressibility and equations of state

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlasic, Thomas M.; Servio, Phillip; Rey, Alejandro D., E-mail: alejandro.rey@mcgill.ca

    2016-08-15

    This work uses density functional theory (DFT) to investigate the poorly characterized structure II gas hydrates, for various guests (empty, propane, butane, ethane-methane, propane-methane), at the atomistic scale to determine key structure and mechanical properties such as equilibrium lattice volume and bulk modulus. Several equations of state (EOS) for solids (Murnaghan, Birch-Murnaghan, Vinet, Liu) were fitted to energy-volume curves resulting from structure optimization simulations. These EOS, which can be used to characterize the compressional behaviour of gas hydrates, were evaluated in terms of their robustness. The three-parameter Vinet EOS was found to perform just as well if not better thanmore » the four-parameter Liu EOS, over the pressure range in this study. As expected, the Murnaghan EOS proved to be the least robust. Furthermore, the equilibrium lattice volumes were found to increase with guest size, with double-guest hydrates showing a larger increase than single-guest hydrates, which has significant implications for the widely used van der Waals and Platteeuw thermodynamic model for gas hydrates. Also, hydrogen bonds prove to be the most likely factor contributing to the resistance of gas hydrates to compression; bulk modulus was found to increase linearly with hydrogen bond density, resulting in a relationship that could be used predictively to determine the bulk modulus of various structure II gas hydrates. Taken together, these results fill a long existing gap in the material chemical physics of these important clathrates.« less

  19. (abstract) The EOS SAR Mission: A New Approach

    NASA Technical Reports Server (NTRS)

    Way, JoBea

    1993-01-01

    The goal of the Earth Orbiting System Synthetic Aperture Radar (EOS SAR) program is to help develop the modeling and observational capabilities to predict and monitor terrestrial and oceanic processes that are either causing global change or resulting from global change. Specifically, the EOS SAR will provide important geophysical products to the EOS data set to improve our understanding of the state and functioning of the Earth system. The strategy for the EOS SAR program is to define the instrument requirements based on required input to geophysical algorithms, provide the processing capability and algorithms to generate such products on the required spatial (global) and temporal (3-5 days) scales, and to provide the spaceborne instrumentation with international partnerships. Initially this partnership has been with Germany; currently we are exploring broader international partnerships. A MultiSAR approach to the EOS SAR which includes a number of SARs provided by Japan, ESA, Germany, Canada, and the US in synergistic orbits could be used to attain a truly global monitoring capability using multifrequency polarimetric signatures. These concepts and several options for mission scenarios will be presented.

  20. Using high-temperature formaldehyde sterilization as a model for studying gaseous sterilization.

    PubMed

    Mosley, Gregg A

    2008-01-01

    This study uses the high-temperature formaldehyde sterilization system provided by the Harvey Chemiclave, manufactured by Barnstead Thermolyne Corporation (Dubuque, IA), as a model to investigate certain phenomena associated with gaseous chemical sterilization systems. Although formaldehyde sterilization presents some unique and complex system attributes, the current studies provide helpful insights into general sterilization methods by chemicals in the gaseous state. Both population recovery and fraction negative (FN) techniques were used to assay surviving populations from biological indicators of the organism Geobacillus stearothermophilus following exposure to incremental Chemiclave cycles. Models 5500 and 6000 of the Barnstead/Thermolyne Chemiclave were used in the study. Reusable instruments such as scalers, explorers, and various hinged pieces were tested in minimum versus maximum load studies. Population recovery study results demonstrated that lethality rates increase with time throughout the Chemiclave sterilization process and that there are significant variations in lethality according to load location. The population recovery data in conjunction with the FN studies and temperature data confirm that one-half the full-cycle time is not a good estimator of one-half the full-cycle lethality because lethality curves are concave downward and lethality varies by load location. This conclusion can also be applied to other types of gaseous, chemical sterilization such as ethylene oxide. The work outlined in this study was a result of investigations into the parameters affecting formaldehyde chemical vapor sterilization with the Harvey Chemiclave sterilizer. During these studies, it became apparent that results clearly depicted the effects of continued acceleration of the rate of microbial lethality, as well as variations in delivered lethality as a function of position in the sterilizer load. This publication focuses on these observations because they are

  1. Observation of Effectiveness of Clinical Sterilization by CASP-80A Low-Temperature Plasma Sterilizer

    NASA Astrophysics Data System (ADS)

    Li, Si; Zhang, Yangde; Liu, Weidong

    2006-09-01

    The influence on the effectiveness of sterilization by low-temperature plasma sterilizer CASP-80A was investigated so as to provide a theoretical basis for reducing medical costs and achieving ideal sterilization effectiveness. To conduct the on-site simulation test, a clinical material sterilization test and a test of the influence of organic substance were conducted, the former by using the representative of Bacillus Stearothermophilus, preparing the bacteria-contaminated carrier through polytetrafluoroethylene (PTFE) simulated hose endoscopes, and the latter by using calf serum as the influence factor of the organic substance. The results show that the CASP-80A low-temperature plasma sterilizer could achieve effective sterilization by either the short-cycle or the long-cycle sterilization method depending on different materials, apparatus, and extent of contamination. The organic substances could influence the effectiveness of sterilization by the low-temperature plasma (H2O2) sterilizer.

  2. Reversible Sterilization

    ERIC Educational Resources Information Center

    Largey, Gale

    1977-01-01

    Notes that difficult questions arise concerning the use of sterilization for alleged eugenic and euthenic purposes. Thus, how reversible sterilization will be used with relation to the poor, mentally ill, mentally retarded, criminals, and minors, is questioned. (Author/AM)

  3. Sterile neutrinos in cosmology

    NASA Astrophysics Data System (ADS)

    Abazajian, Kevork N.

    2017-11-01

    Sterile neutrinos are natural extensions to the standard model of particle physics in neutrino mass generation mechanisms. If they are relatively light, less than approximately 10 keV, they can alter cosmology significantly, from the early Universe to the matter and radiation energy density today. Here, we review the cosmological role such light sterile neutrinos can play from the early Universe, including production of keV-scale sterile neutrinos as dark matter candidates, and dynamics of light eV-scale sterile neutrinos during the weakly-coupled active neutrino era. We review proposed signatures of light sterile neutrinos in cosmic microwave background and large scale structure data. We also discuss keV-scale sterile neutrino dark matter decay signatures in X-ray observations, including recent candidate ∼3.5 keV X-ray line detections consistent with the decay of a ∼7 keV sterile neutrino dark matter particle.

  4. Comparative study of different techniques for the sterilization of poly-L-lactide electrospun microfibers: effectiveness vs. material degradation.

    PubMed

    Rainer, Alberto; Centola, Matteo; Spadaccio, Cristiano; Gherardi, Giovanni; Genovese, Jorge A; Licoccia, Silvia; Trombetta, Marcella

    2010-02-01

    Electrospinning of biopolymeric scaffolds is a new and effective approach for creating replacement tissues to repair defects and/or damaged tissues with direct clinical application. However, many hurdles and technical concerns regarding biological issues, such as cell retention and the ability to grow, still need to be overcome to gain full access to the clinical arena. Interaction with the host human tissues, immunogenicity, pathogen transmission as well as production costs, technical expertise, and good manufacturing and laboratory practice requirements call for careful consideration when aiming at the production of a material that is available off-the-shelf, to be used immediately in operative settings. The issue of sterilization is one of the most important steps for the clinical application of these scaffolds. Nevertheless, relatively few studies have been performed to systematically investigate how sterilization treatments may affect the properties of electrospun polymers for tissue engineering. This paper presents the results of a comparative study of different sterilization techniques applied to an electrospun poly-L-lactide scaffold: soaking in absolute ethanol, dry oven and autoclave treatments, UV irradiation, and hydrogen peroxide gas plasma treatment. Morphological and chemical characterization was coupled with microbiological sterility assay to validate the examined sterilization techniques in terms of effectiveness and modifications to the scaffold. The results of this study reveal that UV irradiation and hydrogen peroxide gas plasma are the most effective sterilization techniques, as they ensure sterility of the electrospun scaffolds without affecting their chemical and morphological features.

  5. [Sterilization and eugenics].

    PubMed

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  6. Analytic EoS and PTW strength model recommendation for Starck Ta

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sjue, Sky K.; Prime, Michael B.

    2016-09-01

    The purpose of this document is to provide an analytic EoS and PTW strength model for Starck Ta that can be consistently used between different platforms and simulations at three labs. This should provide a consistent basis for comparison of the results of calculations, but not the best implementation for matching a wide variety of experimental data. Another version using SESAME tables should follow, which will provide a better physical representation over a broader range of conditions. The data sets available at the time only include one Hopkinson bar at a strain rate of 1800/s; a broader range of high-ratemore » calibration data would be preferred. The resulting fit gives the PTW parameter p = 0. To avoid numerical issues, p = 0:001 has been used in FLAG. The PTW parameters that apply above the maximum strain rate in the data use the values from the original publication.« less

  7. Investigation of Dalton and Amagat's laws for gas mixtures with shock propagation

    NASA Astrophysics Data System (ADS)

    Wayne, Patrick; Trueba Monje, Ignacio; Yoo, Jason H.; Truman, C. Randall; Vorobieff, Peter

    2016-11-01

    Two common models describing gas mixtures are Dalton's Law and Amagat's Law (also known as the laws of partial pressures and partial volumes, respectively). Our work is focused on determining the suitability of these models to prediction of effects of shock propagation through gas mixtures. Experiments are conducted at the Shock Tube Facility at the University of New Mexico (UNM). To validate experimental data, possible sources of uncertainty associated with experimental setup are identified and analyzed. The gaseous mixture of interest consists of a prescribed combination of disparate gases - helium and sulfur hexafluoride (SF6). The equations of state (EOS) considered are the ideal gas EOS for helium, and a virial EOS for SF6. The values for the properties provided by these EOS are then used used to model shock propagation through the mixture in accordance with Dalton's and Amagat's laws. Results of the modeling are compared with experiment to determine which law produces better agreement for the mixture. This work is funded by NNSA Grant DE-NA0002913.

  8. Hysteroscopic Tubal Sterilization

    PubMed Central

    McMartin, K

    2013-01-01

    Background Hysteroscopic tubal sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. The procedures involves non-surgical placement of permanent microinserts into both fallopian tubes. Patients must use alternative contraception for at least 3 months postprocedure until tubal occlusion is confirmed. Compared to tubal ligation, potential advantages of the hysteroscopic procedure are that it can be performed in 10 minutes in an office setting without the use of general or even local anesthesia. Objective The objective of this analysis was to determine the effectiveness and safety of hysteroscopic tubal sterilization compared with tubal ligation for permanent female sterilization. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2008, until December 11, 2012. Review Methods Observational studies, randomized controlled trials (RCTs), systematic reviews and meta-analyses with 1 month or more of follow-up were examined. Outcomes included failure/pregnancy rates, adverse events, and patient satisfaction. Results No RCTs were identified. Two systematic reviews covered 22 observational studies of hysteroscopic sterilization. Only 1 (N = 93) of these 22 studies compared hysteroscopic sterilization to laparoscopic tubal ligation. Two other noncomparative case series not included in the systematic reviews were also identified. In the absence of comparative studies, data on tubal ligation were derived for this analysis from the CREST study, a large, multicentre, prospective, noncomparative observational study in the United States (GRADE low). Overall, hysteroscopic sterilization is associated with lower pregnancy rates and lower complication rates compared to tubal ligation. No deaths have been reported for hysteroscopic sterilization. Limitations A lack of long-term follow-up for hysteroscopic sterilization and a paucity of studies that directly

  9. An investigation of a sterile access technique for the repair and adjustment of sterile spacecraft

    NASA Technical Reports Server (NTRS)

    Farmer, F. H.; Fuller, H. V.; Hueschen, R. M.

    1973-01-01

    A description is presented of a unique system for the sterilization and sterile repair of spacecraft and the results of a test program designed to assess the biological integrity and engineering reliability of the system. This trailer-mounted system, designated the model assembly sterilizer for testing (MAST), is capable of the dry-heat sterilization of spacecraft and/or components less than 2.3 meters in diameter at temperatures up to 433 K and the steam sterilization of components less than 0.724 meter in diameter. Sterile access to spacecraft is provided by two tunnel suits, called the bioisolator suit systems (BISS), which are contiguous with the walls of the sterilization chambers. The test program was designed primarily to verify the biological and engineering reliability of the MAST system by processing simulated space hardware. Each test cycle simulated the initial sterilization of a spacecraft, sterile repair of a failed component, removal of the spacecraft from the MAST for mating with the bus, and a sterile recycle repair.

  10. The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.

    PubMed

    Engh, Charles A; Powers, Cara C; Ho, Henry; Beykirch-Padgett, Sarah E; Hopper, Robert H; Engh, C Anderson

    2012-02-01

    During the mid-1990s when our institution was using a press-fit porous-coated cup without supplemental initial fixation for primary THA, the manufacturer transitioned from gamma irradiation to gas plasma for the terminal sterilization of their polyethylene liners. At minimum 10-year followup, we asked whether the fixation achieved by solely relying on a press-fit would be durable and how different liner sterilization methods affected radiographic wear, osteolysis, and survivorship. We retrospectively reviewed 373 patients who underwent 398 primary THAs with a press-fit porous-coated cup between March 1995 and December 1996. Mean age at time of surgery was 61.5 ± 13.3 years and mean followup was 10.4 ± 3.7 years. We determined reasons for revision, survivorship, femoral head penetration, osteolysis, and wear-related complications. Among 20 revisions involving any component, seven were associated with wear and osteolysis. Kaplan-Meier survivorship, using component revision for any reason as an end point, was 95.7% (95% confidence interval, 93.6%-97.9%) at 10 years. Noncrosslinked liners sterilized with gas plasma demonstrated a mean head penetration rate of 0.20 ± 0.09 mm/year compared with 0.13 ± 0.07 mm/year for liners sterilized with gamma irradiation in air and 0.09 ± 0.04 mm/year for liners sterilized with gamma-irradiation with barrier packaging without oxygen. THAs with increased volumetric wear tended to demonstrate larger osteolytic lesions (r = 0.40) and there tended to be less osteolysis among the liners sterilized with gamma-irradiation with barrier packaging without oxygen. However, there was no difference in survivorship among the sterilization groups and there has been no cup or stem loosening associated with osteolysis. Durable biologic fixation through 10-year followup can be achieved by solely relying on an initial press-fit. Noncrosslinking gas plasma for terminal sterilization of the polyethylene liners was associated with greater head

  11. Reversibility of female sterilization.

    PubMed

    Siegler, A M; Hulka, J; Peretz, A

    1985-04-01

    The discussion considers the current status of reversibility of sterilization in the US and describes clinical and experimental efforts for developing techniques designed for reversibility. It focuses on regret following sterilization, reversal potential of current sterilization techniques, patient selection, current reversal techniques, results of sterilization procedures, experimental approaches to reversal of current techniques of sterilization, and sterilization procedures devised for reversibility, in humans and in animals. Request is the 1st stage of reversal, but a request for sterilization reversal (SR) does not always mean regret for a decision made at the time. Frequently it is a wish to restore fertility because life circumstances have changed after a sterilization that was ppropriate at the time it was performed. Schwyhart and Kutner reviewed 22 studies published between 1949-69 in which they found that the percentage of patients regretting the procedure ranged from 1.3-15%. Requests for reversal remain low in most countries, but if sterilization becomes a more popular method of contraception, requests will also increase. The ideal operation considered as a reversaible method of sterilization should include an easy, reliable outpatient method of tubal occlusion with miniml risk or patient discomfort that subsequently could be reversed without the need for a major surgical intervention. Endoscopic methods have progressed toward the 1st objective. A recent search of the literature uncovered few series of SR of more than 50 cases. The 767 operations found were analyzed with regard to pregnancy outcome. The precent of live births varied from 74-78.8%, and the occurance of tubal pregnancies ranged from 1.7-6.5%. All of the confounding variables in patient selection and small numbers of reported procedures preclude any conclusion about the different techniques or the number of operations that give a surgeon a level of expertise. Few authors classify their

  12. Development of a sterilizing in-place application for a production machine using Vaporized Hydrogen Peroxide.

    PubMed

    Mau, T; Hartmann, V; Burmeister, J; Langguth, P; Häusler, H

    2004-01-01

    The use of steam in sterilization processes is limited by the implementation of heat-sensitive components inside the machines to be sterilized. Alternative low-temperature sterilization methods need to be found and their suitability evaluated. Vaporized Hydrogen Peroxide (VHP) technology was adapted for a production machine consisting of highly sensitive pressure sensors and thermo-labile air tube systems. This new kind of "cold" surface sterilization, known from the Barrier Isolator Technology, is based on the controlled release of hydrogen peroxide vapour into sealed enclosures. A mobile VHP generator was used to generate the hydrogen peroxide vapour. The unit was combined with the air conduction system of the production machine. Terminal vacuum pumps were installed to distribute the gas within the production machine and for its elimination. In order to control the sterilization process, different physical process monitors were incorporated. The validation of the process was based on biological indicators (Geobacillus stearothermophilus). The Limited Spearman Karber Method (LSKM) was used to statistically evaluate the sterilization process. The results show that it is possible to sterilize surfaces in a complex tube system with the use of gaseous hydrogen peroxide. A total microbial reduction of 6 log units was reached.

  13. Sterilization: A Review and Update.

    PubMed

    Moss, Chailee; Isley, Michelle M

    2015-12-01

    Sterilization is a frequently used method of contraception. Female sterilization is performed 3 times more frequently than male sterilization, and it can be performed immediately postpartum or as an interval procedure. Methods include mechanical occlusion, coagulation, or tubal excision. Female sterilization can be performed using an abdominal approach, or via laparoscopy or hysteroscopy. When an abdominal approach or laparoscopy is used, sterilization occurs immediately. When hysteroscopy is used, tubal occlusion occurs over time, and additional testing is needed to confirm tubal occlusion. Comprehensive counseling about sterilization should include discussion about male sterilization (vasectomy) and long-acting reversible contraceptive methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Sterilization of Fusarium oxysporum by treatment of non-thermalequilibrium plasma in nutrient solution

    NASA Astrophysics Data System (ADS)

    Yasui, Shinji; Seki, Satoshi; Yoshida, Ryohei; Shoji, Kazuhiro; Terazoe, Hitoshi

    2016-01-01

    Fusarium wilt of spinach due to F. oxysporum infection is one of the most destructive root diseases in hydroponics in factories using the nutrient film technique. We investigated new technologies for the sterilization of microconidia of F. oxysporum by using a non-thermalequilibrium plasma treatment method in nutrient solution. Specifically, we investigated the sterilization capabilities of five types of gas (air, O2, N2, He, and Ar) used for plasma generation. The highest sterilization capability was achieved by using O2 plasma. However, ozone, which causes growth inhibition, was then generated and released into the atmosphere. The sterilization capability was lower when N2 or air plasma was used in the nutrient solution. It was confirmed that sterilization can be achieved by plasma treatment using inert gases that do not generate ozone; therefore, we determined that Ar plasma is the most preferable. In addition, we investigated the sterilization capabilities of other factors associated with Ar plasma generation, without direct plasma treatment. However, none of these other factors, which included Ar bubbling, pH reduction, increased temperature, hydrogen peroxide concentration, and UV radiation, could completely reproduce the results of direct plasma treatment. We assume that radicals such as O or OH may contribute significantly to the sterilization of microconidia of F. oxysporum in a nutrient solution.

  15. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study.

    PubMed

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter; Sedrakyan, Art

    2015-10-13

    To compare the safety and efficacy of hysteroscopic sterilization with the "Essure" device with laparoscopic sterilization in a large, all-inclusive, state cohort. Population based cohort study. Outpatient interventional setting in New York State. Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. We identified 8048 patients undergoing hysteroscopic sterilization and 44,278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures should be discussed with patients for informed decisions making. © Mao et al 2015.

  16. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study

    PubMed Central

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter

    2015-01-01

    Objective To compare the safety and efficacy of hysteroscopic sterilization with the “Essure” device with laparoscopic sterilization in a large, all-inclusive, state cohort. Design Population based cohort study. Settings Outpatient interventional setting in New York State. Participants Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Main outcomes measures Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. Results We identified 8048 patients undergoing hysteroscopic sterilization and 44 278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Conclusions Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures

  17. Initial Scientific Assessment of the EOS Data and Information System (EOSDIS)

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Crucial to the success of the Earth Observing System (Eos) is the Eos Data and Information System (EosDIS). The goals of Eos depend not only on its instruments and science investigations, but also on how well EosDlS helps scientists integrate reliable, large-scale data sets of geophysical and biological measurements made from Eos data, and on how successfully Eos scientists interact with other investigations in Earth System Science. Current progress in the use of remote sensing for science is hampered by requirements that the scientist understand in detail the instrument, the electromagnetic properties of the surface, and a suite of arcane tape formats, and by the immaturity of some of the techniques for estimating geophysical and biological variables from remote sensing data. These shortcomings must be transcended if remote sensing data are to be used by a much wider population of scientists who study environmental change at regional and global scales.

  18. Sterilization for Women and Men

    MedlinePlus

    f AQ FREQUENTLY ASKED QUESTIONS FAQ011 CONTRACEPTION Sterilization for Women and Men • What is sterilization? • How does tubal occlusion work to prevent pregnancy? • How effective is female sterilization? • Does female sterilization ...

  19. EOS-AM precision pointing verification

    NASA Technical Reports Server (NTRS)

    Throckmorton, A.; Braknis, E.; Bolek, J.

    1993-01-01

    The Earth Observing System (EOS) AM mission requires tight pointing knowledge to meet scientific objectives, in a spacecraft with low frequency flexible appendage modes. As the spacecraft controller reacts to various disturbance sources and as the inherent appendage modes are excited by this control action, verification of precision pointing knowledge becomes particularly challenging for the EOS-AM mission. As presently conceived, this verification includes a complementary set of multi-disciplinary analyses, hardware tests and real-time computer in the loop simulations, followed by collection and analysis of hardware test and flight data and supported by a comprehensive data base repository for validated program values.

  20. Energy Referencing in LANL HE-EOS Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leiding, Jeffery Allen; Coe, Joshua Damon

    2017-10-19

    Here, We briefly describe the choice of energy referencing in LANL's HE-EOS codes, HEOS and MAGPIE. Understanding this is essential to comparing energies produced by different EOS codes, as well as to the correct calculation of shock Hugoniots of HEs and other materials. In all equations after (3) throughout this report, all energies, enthalpies and volumes are assumed to be molar quantities.

  1. Mission operations update for the restructured Earth Observing System (EOS) mission

    NASA Technical Reports Server (NTRS)

    Kelly, Angelita Castro; Chang, Edward S.

    1993-01-01

    The National Aeronautics and Space Administration's (NASA) Earth Observing System (EOS) will provide a comprehensive long term set of observations of the Earth to the Earth science research community. The data will aid in determining global changes caused both naturally and through human interaction. Understanding man's impact on the global environment will allow sound policy decisions to be made to protect our future. EOS is a major component of the Mission to Planet Earth program, which is NASA's contribution to the U.S. Global Change Research Program. EOS consists of numerous instruments on multiple spacecraft and a distributed ground system. The EOS Data and Information System (EOSDIS) is the major ground system developed to support EOS. The EOSDIS will provide EOS spacecraft command and control, data processing, product generation, and data archival and distribution services for EOS spacecraft. Data from EOS instruments on other Earth science missions (e.g., Tropical Rainfall Measuring Mission (TRMM)) will also be processed, distributed, and archived in EOSDIS. The U.S. and various International Partners (IP) (e.g., the European Space Agency (ESA), the Ministry of International Trade and Industry (MITI) of Japan, and the Canadian Space Agency (CSA)) participate in and contribute to the international EOS program. The EOSDIS will also archive processed data from other designated NASA Earth science missions (e.g., UARS) that are under the broad umbrella of Mission to Planet Earth.

  2. Results from the MWA EoR Experiment

    NASA Astrophysics Data System (ADS)

    Webster, Rachel L.; MWA EoR Collaboration

    2018-05-01

    The MWA EoR is one of a small handful of experiments designed to detect the statistical signal from the Epoch of Reionisation. Each of these experiments has reached a level of maturity, where the challenges, in particular of foreground removal, are being more fully understood. Over the past decade, the MWA EoR Collaboration has developed expertise and an understanding of the elements of the telescope array, the end-to-end pipelines, ionospheric conditions, and and the foreground emissions. Sufficient data has been collected to detect the theoretically predicted EoR signal. Limits have been published regularly, however we still several orders of magnitude from a possible detection. This paper outlines recent progress and indicates directions for future efforts.

  3. Eosinophilic Esophagitis (EoE)

    MedlinePlus

    ... the AAAAI Foundation Donate Utility navigation Español Journals Pollen Counts Annual Meeting Member Login / My Membership Search ... allergies to substances such as dust mites, animals, pollen and molds can play a role in EoE. ...

  4. Supernova constraints on neutrino oscillation and EoS for proto-neutron star

    NASA Astrophysics Data System (ADS)

    Kajino, T.; Aoki, W.; Cheoun, M.-K.; Hayakawa, T.; Hidaka, J.; Hirai, Y.; Mathews, G. J.; Nakamura, K.; Shibagaki, S.; Suzuki, T.

    2014-05-01

    Core-collapse supernovae eject huge amount of flux of energetic neutrinos which affect explosive nucleosynthesis of rare isotopes like 7Li, 11B, 92Nb, 138La and Ta and r-process elements. Several isotopes depend strongly on the neutrino flavor oscillation due to the Mikheyev-Smirnov-Wolfenstein (MSW) effect. We here discuss how to determine the neutrino temperatures and propose a method to determine still unknown neutrino oscillation parameters, mass hierarchy and θ13, simultaneously. Combining the recent experimental constraints on θ13 with isotopic ratios of the light elements discovered in presolar grains from the Murchison meteorite, we show that our method suggests at a marginal preference for an inverted neutrino mass hierarchy. We also discuss supernova relic neutrinos that may indicate the softness of the equation of state (EoS) of nuclear matter as well as adiabatic conditions of the neutrino oscillation.

  5. Earth Observatory Satellite system definition study. Report no. 3: Design/cost tradeoff studies. Appendix A: EOS program WBS dictionary. Appendix B: EOS mission functional analysis

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The work breakdown structure (WBS) dictionary for the Earth Observatory Satellite (EOS) is defined. The various elements of the EOS program are examined to include the aggregate of hardware, computer software, services, and data required to develop, produce, test, support, and operate the space vehicle and the companion ground data management system. A functional analysis of the EOS mission is developed. The operations for three typical EOS missions, Delta, Titan, and Shuttle launched are considered. The functions were determined for the top program elements, and the mission operations, function 2.0, was expanded to level one functions. Selection of ten level one functions for further analysis to level two and three functions were based on concern for the EOS operations and associated interfaces.

  6. Sterile neutrino dark matter production

    NASA Astrophysics Data System (ADS)

    Gorbunov, Dmitry

    2017-10-01

    Sterile neutrinos provide active neutrinos with masses and mixing, and hence is one of the well-motivated candidate for dark matter. We discuss the sterile neutrino production mechanisms operating in the early Universe and show that additional scalar coupled to sterile neutrino can significantly change the situation, making moderate sterile-neutrino mixing and small sterile neutrino masses consistent with current cosmological and astrophysical bounds. Further searches for a narrow line in galactic X-rays and even direct searches for keV-scale sterile neutrinos in particle physics experiments can probe the suggested setup.

  7. Radiation sterilization of enzyme hybrids with biodegradable polymers

    NASA Astrophysics Data System (ADS)

    Furuta, Masakazu; Oka, Masahito; Hayashi, Toshio

    2002-03-01

    Ionizing radiations, which have already been utilized for the sterilization of medical supplies as well as gas fumigation, should be the final candidate to decontaminate "hybrid" biomaterials containing bio-active materials including enzymes because irradiation induces neither heat nor substances affecting the quality of the materials and our health. In order to check the feasibility of 60Co-gamma rays on these materials, we selected commercial proteases including papain and bromelain hybridized with commercial activated chitosan beads and demonstrated that these enzyme-hybrids suspended in water showed the significant radiation durability of more than twice as much as free enzyme solution at 25-kGy irradiation. Enhanced thermal and storage stability of the enzyme hybrids were not affected by the same dose level of irradiation, either, indicating that commercial irradiation sterilization method is applicable to enzyme hybrids without modification.

  8. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device...

  9. The sterilization of endodontic hand files.

    PubMed

    Hurtt, C A; Rossman, L E

    1996-06-01

    Several different methods of file sterilization were analyzed to determine the best method of providing complete file sterility, including the metal shaft and plastic handle. Six test groups of 15 files were studied using Bacillus stearothermophilus as the test organism. Groups were "sterilized" by glutaraldehyde immersion, steam autoclaving, and various techniques of salt sterilization. Only proper steam autoclaving reliably produced completely sterile instruments. Salt sterilization and glutaraldehyde solutions may not be adequate sterilization methods for endodontic hand files and should not be relied on to provide completely sterile instruments.

  10. Comparison of two radio-frequency plasma sterilization processes using microspot evaluation of microbial inactivation.

    PubMed

    Lassen, Klaus S; Johansen, Jens E; Grün, Reinar

    2006-07-01

    In this study, we evaluated gas plasma surface sterilization methods in a specific sterilizer. We have introduced a new monitoring method using 0.4 microm pore size membranes, which in this study gave the information corresponding to 3000 exposed biological indicators per treatment cycle. This enabled us to compare the fraction of inoculates that showed no growth after exposure for 30 different locations in the chamber, and hereby identify weak and strong spots in the chamber with regard to sporicidal effect. Membranes were also used to expose a broad spectrum of soil bacteria for plasma treatment at four different conditions. The organisms were identified using PCR and sequencing. The test showed that Bacillus stearothermophilus spores were inactivated at the slowest rate among the tested microorganisms. Further alpha-proteobacteria (Gram negative) seemed more sensitive than the rest of the tested organisms. The microspot evaluation approach has been a most useful tool in the assessment of sterilization performance in sterilizers that do not have clear measurable parameters related to the sterilization.

  11. SenSyF Experience on Integration of EO Services in a Generic, Cloud-Based EO Exploitation Platform

    NASA Astrophysics Data System (ADS)

    Almeida, Nuno; Catarino, Nuno; Gutierrez, Antonio; Grosso, Nuno; Andrade, Joao; Caumont, Herve; Goncalves, Pedro; Villa, Guillermo; Mangin, Antoine; Serra, Romain; Johnsen, Harald; Grydeland, Tom; Emsley, Stephen; Jauch, Eduardo; Moreno, Jose; Ruiz, Antonio

    2016-08-01

    SenSyF is a cloud-based data processing framework for EO- based services. It has been pioneer in addressing Big Data issues from the Earth Observation point of view, and is a precursor of several of the technologies and methodologies that will be deployed in ESA's Thematic Exploitation Platforms and other related systems.The SenSyF system focuses on developing fully automated data management, together with access to a processing and exploitation framework, including Earth Observation specific tools. SenSyF is both a development and validation platform for data intensive applications using Earth Observation data. With SenSyF, scientific, institutional or commercial institutions developing EO- based applications and services can take advantage of distributed computational and storage resources, tailored for applications dependent on big Earth Observation data, and without resorting to deep infrastructure and technological investments.This paper describes the integration process and the experience gathered from different EO Service providers during the project.

  12. Eos Chasma - False Color

    NASA Image and Video Library

    2014-12-16

    The THEMIS VIS camera contains 5 filters. The data from different filters can be combined in multiple ways to create a false color image. This false color image from NASA 2001 Mars Odyssey spacecraft shows part of of Eos Chasma.

  13. Supernova constraints on neutrino oscillation and EoS for proto-neutron star

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kajino, T.; Aoki, W.; Cheoun, M.-K.

    2014-05-02

    Core-collapse supernovae eject huge amount of flux of energetic neutrinos which affect explosive nucleosynthesis of rare isotopes like {sup 7}Li, {sup 11}B, {sup 92}Nb, {sup 138}La and Ta and r-process elements. Several isotopes depend strongly on the neutrino flavor oscillation due to the Mikheyev-Smirnov-Wolfenstein (MSW) effect. We here discuss how to determine the neutrino temperatures and propose a method to determine still unknown neutrino oscillation parameters, mass hierarchy and θ{sub 13}, simultaneously. Combining the recent experimental constraints on θ{sub 13} with isotopic ratios of the light elements discovered in presolar grains from the Murchison meteorite, we show that our methodmore » suggests at a marginal preference for an inverted neutrino mass hierarchy. We also discuss supernova relic neutrinos that may indicate the softness of the equation of state (EoS) of nuclear matter as well as adiabatic conditions of the neutrino oscillation.« less

  14. Novel EO/IR sensor technologies

    NASA Astrophysics Data System (ADS)

    Lewis, Keith

    2011-10-01

    The requirements for advanced EO/IR sensor technologies are discussed in the context of evolving military operations, with significant emphasis on the development of new sensing technologies to meet the challenges posed by asymmetric threats. The Electro-Magnetic Remote Sensing (EMRS DTC) was established in 2003 to provide a centre of excellence in sensor research and development, supporting new capabilities in key military areas such as precision attack, battlespace manoeuvre and information superiority. In the area of advanced electro-optic technology, the DTC has supported work on discriminative imaging, advanced detectors, laser components/technologies, and novel optical techniques. This paper provides a summary of some of the EO/IR technologies explored by the DTC.

  15. Eos Negatively Regulates Human γ-globin Gene Transcription during Erythroid Differentiation

    PubMed Central

    Yu, Hai-Chuan; Zhao, Hua-Lu; Wu, Zhi-Kui; Zhang, Jun-Wu

    2011-01-01

    Background Human globin gene expression is precisely regulated by a complicated network of transcription factors and chromatin modifying activities during development and erythropoiesis. Eos (Ikaros family zinc finger 4, IKZF4), a member of the zinc finger transcription factor Ikaros family, plays a pivotal role as a repressor of gene expression. The aim of this study was to examine the role of Eos in globin gene regulation. Methodology/Principal Findings Western blot and quantitative real-time PCR detected a gradual decrease in Eos expression during erythroid differentiation of hemin-induced K562 cells and Epo-induced CD34+ hematopoietic stem/progenitor cells (HPCs). DNA transfection and lentivirus-mediated gene transfer demonstrated that the enforced expression of Eos significantly represses the expression of γ-globin, but not other globin genes, in K562 cells and CD34+ HPCs. Consistent with a direct role of Eos in globin gene regulation, chromatin immunoprecipitaion and dual-luciferase reporter assays identified three discrete sites located in the DNase I hypersensitivity site 3 (HS3) of the β-globin locus control region (LCR), the promoter regions of the Gγ- and Aγ- globin genes, as functional binding sites of Eos protein. A chromosome conformation capture (3C) assay indicated that Eos may repress the interaction between the LCR and the γ-globin gene promoter. In addition, erythroid differentiation was inhibited by enforced expression of Eos in K562 cells and CD34+ HPCs. Conclusions/Significance Our results demonstrate that Eos plays an important role in the transcriptional regulation of the γ-globin gene during erythroid differentiation. PMID:21829552

  16. [Regret of female sterilization].

    PubMed

    Öhman, Malin Charlotta; Andersen, Lars Franch

    2015-11-16

    Regret of sterilization is inversely correlated to age at the time of sterilization. The minimum age for legal sterilization in Denmark has recently been lowered to 18 years. In Denmark surgical refertilization has almost completely been replaced by in vitro fertilization (IVF). In recent literature pregnancy results after surgical refertilization are easily comparable to IVF. Refertilization may in some cases be advantageous to IVF treatment. Women requesting reversal of sterilization should be offered individualized evaluation and differentiated treatment. It is recommended that surgical refertilization is performed at very few centres.

  17. Sterilizing the Poor

    ERIC Educational Resources Information Center

    Rothman, Sheila M.

    1977-01-01

    Suggests that freedom for the middle classes may mean vulnerability for the poor. The enthusiasm for sterilization may be so intense as to deprive the poor of their right not to be sterilized. (Author/AM)

  18. The backcross sterility technique

    Treesearch

    V. C. Mastro; A. Pellegrini-Toole

    1991-01-01

    The sterile insect technique (SIT) and the induced inherited (F1) sterility technique have been investigated for a number of lepidopterous pests, including the gypsy moths. Another technique, backcross sterility, which could potentially prove as or more useful for control of pest species has been developed for the control of only one lepidopteran...

  19. CERNBox + EOS: end-user storage for science

    NASA Astrophysics Data System (ADS)

    Mascetti, L.; Gonzalez Labrador, H.; Lamanna, M.; Mościcki, JT; Peters, AJ

    2015-12-01

    CERNBox is a cloud synchronisation service for end-users: it allows syncing and sharing files on all major mobile and desktop platforms (Linux, Windows, MacOSX, Android, iOS) aiming to provide offline availability to any data stored in the CERN EOS infrastructure. The successful beta phase of the service confirmed the high demand in the community for an easily accessible cloud storage solution such as CERNBox. Integration of the CERNBox service with the EOS storage back-end is the next step towards providing “sync and share” capabilities for scientific and engineering use-cases. In this report we will present lessons learnt in offering the CERNBox service, key technical aspects of CERNBox/EOS integration and new, emerging usage possibilities. The latter includes the ongoing integration of “sync and share” capabilities with the LHC data analysis tools and transfer services.

  20. EOS situational data shared service mechanism

    NASA Astrophysics Data System (ADS)

    Lv, L.; Xu, Q.; Lan, C. Z.; Shi, Q. S.; Lu, W. J.; Wu, W. Q.

    2016-11-01

    With the rapid development of aerospace and remote sensing technology, various high-resolution Earth Observation Systems (EOS) are widely used in economic, social, military and other fields and playing an increasingly prominent role in the construction of Digital Earth and national strategic planning. The normal operation of the system is the premise of high quality data acquisition. Compared with the ground observation mode, EOS itself and the surrounding environment are more complex, and its operation control mainly depends on all kinds of Space Situational Awareness (SSA) data acquisition and analysis. SSA data has more extensive sources, larger volume, stronger time-effectiveness and more complicated structure than traditional geographical spatial data. For effective data sharing and utilization, combined with the analysis of data types and structures, a SSA data sharing identity language SSDSML is designed based on the extensible mark-up language XML, which realizes a comprehensive description of satellites and their attributes, space environment, ground stations, etc. Then EOS situational data shared service mechanism is established and provides a powerful data support for the normal operation of the system.

  1. Potential commercial uses of EOS remote sensing products

    NASA Technical Reports Server (NTRS)

    Thompson, Leslie L.

    1991-01-01

    The instrument complement of the Earth Observing System (EOS) satellite system will generate data sets with potential interest to a variety of users who are now just beginning to develop geographic information systems tailored to their special applications and/or jurisdictions. Other users may be looking for a unique product that enhances competitive position. The generally distributed products from EOS will require additional value added processing to derive the unique products desired by specific users. Entrepreneurs have an opportunity to create these proprietary level 4 products from the EOS data sets. Specific instruments or collections of instruments could provide information for crop futures trading, mineral exploration, television and printed medium news products, regional and local government land management and planning, digital map directories, products for third world users, ocean fishing fleet probability of harvest forecasts, and other areas not even imagined at this time. The projected level 3 product are examined that will be available at launch from EOS instruments and commercial uses of the data after value added processing is estimated.

  2. Rigorous theoretical constraint on constant negative EoS parameter [Formula: see text] and its effect for the late Universe.

    PubMed

    Burgazli, Alvina; Eingorn, Maxim; Zhuk, Alexander

    In this paper, we consider the Universe at the late stage of its evolution and deep inside the cell of uniformity. At these scales, the Universe is filled with inhomogeneously distributed discrete structures (galaxies, groups and clusters of galaxies). Supposing that the Universe contains also the cosmological constant and a perfect fluid with a negative constant equation of state (EoS) parameter [Formula: see text] (e.g., quintessence, phantom or frustrated network of topological defects), we investigate scalar perturbations of the Friedmann-Robertson-Walker metrics due to inhomogeneities. Our analysis shows that, to be compatible with the theory of scalar perturbations, this perfect fluid, first, should be clustered and, second, should have the EoS parameter [Formula: see text]. In particular, this value corresponds to the frustrated network of cosmic strings. Therefore, the frustrated network of domain walls with [Formula: see text] is ruled out. A perfect fluid with [Formula: see text] neither accelerates nor decelerates the Universe. We also obtain the equation for the nonrelativistic gravitational potential created by a system of inhomogeneities. Due to the perfect fluid with [Formula: see text], the physically reasonable solutions take place for flat, open and closed Universes. This perfect fluid is concentrated around the inhomogeneities and results in screening of the gravitational potential.

  3. EosFit-Pinc: a GUI program to calculate pressures in host-inclusion systems

    NASA Astrophysics Data System (ADS)

    Angel, Ross; Alvaro, Matteo; Mazzucchelli, Mattia; Nestola, Fabrizio

    2017-04-01

    A remnant pressure in an inclusion trapped inside a host mineral is developed because the inclusion and the host have different thermal expansion and compressibilities, and the inclusion does not expand in response to P and T as would a free crystal. Instead it is restricted to expand only as much as the cavity of the host mineral, and this constriction in volume can result in inclusions exhibiting over-pressures when the host is studied at room conditions. The remnant pressure of the inclusion, measured by X-ray diffractometry, birefringence analysis or Raman spectroscopy, can then be used with the equations of state (EoS) of the host and inclusion to constrain the P and T at entrapment. This concept has been known for a long time, but satisfactory quantitative modelling of inclusion-host systems based on non-linear elasticity theory and precise EoS has only recently come available (Angel et al., 2014, 2015), even though calculations still assume isotropic elastic properties. The elasticity calculations to determine entrapment conditions involving the EoSs for both the host and the inclusion are complex if thermodynamically-realistic EoS are employed. We have therefore developed a simple GUI program, EosFit-Pinc that performs all of the necessary calculations under the assumptions of isotropic elasticity. Equations of state of the host and the inclusion can be loaded as files created by other software in the EosFit7 program suite, or imported directly from thermodynamic databases such as Thermocalc. The complete range of EoS types supported by EosFit-7 are available in EosFit-Pinc. Fluid EoS can be provided in the form of PVT tables, which allows fluid inclusions to be modelled. Once loaded, the EoS of the host and inclusion can be used to calculate the entrapment isomeke from the measured remnant pressure of the inclusion. Or the final pressure can be calculated if the entrapment conditions are known or estimated. Calculations of the isochors of both the host and

  4. Thermal sterilization of heat-sensitive products using high-temperature short-time sterilization.

    PubMed

    Mann, A; Kiefer, M; Leuenberger, H

    2001-03-01

    High-temperature short-time (HTST) sterilization with a continuous-flow sterilizer, developed for this study, was evaluated. The evaluation was performed with respect to (a) the chemical degradation of two heat-sensitive drugs in HTST range (140-160 degrees C) and (b) the microbiological effect of HTST sterilization. Degradation kinetics of two heat-sensitive drugs showed that a high peak temperature sterilization process resulted in less chemical degradation for the same microbiological effect than a low peak temperature process. Both drugs investigated could be sterilized with acceptable degradation at HTST conditions. For the evaluation of the microbiological effect, Bacillus stearothermophilus ATCC 7953 spores were used as indicator bacteria. Indicator spore kinetics (D(T), z value, k, and E(a)), were determined in the HTST range. A comparison between the Bigelow model (z value concept) and the Arrhenius model, used to describe the temperature coefficient of the microbial inactivation, demonstrated that the Bigelow model is more accurate in prediction of D(T) values in the HTST range. The temperature coefficient decreased with increasing temperature. The influence of Ca(2+) ions and pH value on the heat resistance of the indicator spores, which is known under typical sterilization conditions, did not change under HTST conditions.

  5. Evaluation of glutaraldehyde and povidone iodine for sterilization of wide-field contact vitrectomy lenses.

    PubMed

    Das, T; Sharma, S; Singh, J; Rao, V; Chalam, K V

    2001-01-01

    Wide-field vitrectomy contact lenses are currently sterilized with ethylene oxide gas, and other lenses with autoclaving. To maintain a large inventory or possibly run the risk of loss of lens quality with repeated autoclaving, glutaraldehyde 2% and povidone iodine 5% solution were evaluated as possible sterilizing agents. Ethylene oxide presterilized lenses were contaminated with known concentrations (10(5) organisms/mL) of bacteria (S. epidemidis, P. aeruginosa, B. subtilis), and fungi (A. flavus, C. albicans) for 5 minutes. The test lenses were treated with glutaraldehyde or povidone iodine for 5, 10, 30, 60, and 120 minutes, and controls with sterilized water for a similar duration. Following treatment, both test and control lenses were sampled with sterile cotton swabs. The swabs were cultured for bacteria (tryptone soya broth 48 hours), and fungi (Saubourd's dextrose broth 5 days). The culture was negative for both glutaraldehyde- and povidone iodine-treated lenses against all organisms at all time points except B subtilis, which needed 120 minutes treatment. Two hours contact time with glutaraldehyde 2% or providone iodine 5% can sterilize vitrectomy contact lenses against common bacteria and fungi without affecting lens quality.

  6. Sterilization in Finland: from eugenics to contraception.

    PubMed

    Hemminki, E; Rasimus, A; Forssas, E

    1997-12-01

    The purpose of this paper was to describe the transition of sterilization in Finland from an eugenic tool to a contraceptive. Historical data were drawn from earlier reports in Finnish. Numbers of and reasons for sterilizations since 1950 were collected from nationwide sterilization statistics. Prevalence, characteristics of sterilized women, and women's satisfaction with sterilizations were studied from a 1994 nationwide survey (74% response rate). Logistic regression was used for adjustments. In the first half of the 20th century, eugenic ideology had influence in Finland as in other parts of Europe, and the 1935 and 1950 sterilization laws had an eugenic spirit. Regardless of this, the numbers of eugenic sterilizations remained low, and in practice, family planning was the main reason for sterilization. Nonetheless, prior to 1970 not all sterilizations were freely chosen, because sterilizations were sometimes used as a precondition for abortion. Female sterilizations showed remarkable fluctuation over time. Male sterilizations have been rare. The reasons stipulated by the law did not explain the numbers of sterilizations. In a 1994 survey, 9% of Finnish women reported they were using sterilization as their current contraceptive method (n = 189). Compared to women using other contraceptive methods, sterilized women were older, had had more births and pregnancies, and came from lower social classes. Sterilized women were satisfied with their sterilization, but there were women (8.5%) who regretted it. In conclusion, sterilizations have been and are likely to continue to be an important family planning method in Finland. The extreme gender ratio suggests a need for promoting male sterilizations, and women's expressed regrets suggest consideration of a higher age limit.

  7. Contraception Update: Sterilization.

    PubMed

    Antell, Karen; Deshmukh, Prium; Brown, Elizabeth J

    2017-11-01

    Female sterilization procedures include postpartum partial salpingectomy via cesarean or minilaparotomy incision, interval laparoscopic procedures, or hysteroscopic placement of microinserts. Rates of failure and serious complications are low and comparable among the various methods. A hysteroscopic procedure requires a 3-month confirmatory hysterosalpingogram before it is considered effective for contraception. Hysteroscopic sterilization has been shown to be associated with a higher reoperation rate than laparoscopic procedures. For male sterilization, vasectomy is a noninvasive and highly effective method. Vasectomy is an outpatient procedure performed under local anesthesia. The procedure requires confirmation of azoospermia with a semen analysis 8 to 16 weeks after the procedure. Patients who are considering sterilization should be counseled about all the available options and the permanent nature of such procedures. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  8. Sterilization and its consequences.

    PubMed

    Hendrix, N W; Chauhan, S P; Morrison, J C

    1999-12-01

    The purpose of this review is to analyze critically the two techniques of sterilization (bilateral tubal ligation [BTL] and vasectomy) so that a physician may provide informed consent about methods of sterilization. A MEDLINE search and extensive review of published literature dating back to 1966 was undertaken to compare preoperative counseling, operative procedures, postoperative complications, procedure-related costs, psychosocial consequences, and feasibility of reversal between BTL and a vasectomy. Compared with a vasectomy, BTL is 20 times more likely to have major complications, 10 to 37 times more likely to fail, and cost three times as much. Moreover, the procedure-related mortality, although rare, is 12 times higher with sterilization of the woman than of the man. Despite these advantages, 300,000 more BTLs were done in 1987 than vasectomies. In 1987, there were 976,000 sterilizations (65 percent BTLs and 35 percent vasectomies) with an overall cost of $1.8 billion. Over $260 million could have been saved if equal numbers of vasectomies and BTLs had been performed, or more than $800 million if 80 percent had been vasectomies, as was the case in 1971. The safest, most efficacious, and least expensive method of sterilization is vasectomy. For these reasons, physicians should recommend vasectomy when providing counseling on sterilization, despite the popularity of BTL. Obstetricians & Gynecologists, Family Physicians After completion of this article, the reader will be able to predict the failure rates and likelihood of successful reversal of tubal ligation and vasectomy; to recall the difference in cost between the two sterilization procedures, and to describe the short-term and long-term complications associated with each of the two methods of sterilization.

  9. Quantifying real-gas effects on a laminar n-dodecane - air premixed flame

    NASA Astrophysics Data System (ADS)

    Gopal, Abishek; Yellapantula, Shashank; Larsson, Johan

    2015-11-01

    With the increasing demand for higher efficiencies in aircraft gas-turbine engines, there has been a progressive march towards high pressure-ratio cycles. Under these conditions, the aviation fuel, Jet A, is injected into the combustor at supercritical pressures. In this work, we study and quantify the effects of transcriticality on a 1D freely propagating laminar n-dodecane - air premixed flame. The impact of the constitutive state relations arising from the Ideal Gas equation of state(EOS) and Peng-Robinson EOS on flame structure and propagation is presented. The effects of real-gas models of transport properties, such as viscosity on laminar flame speed, are also presented.

  10. Overview of EO polymers and polymer modulator stability

    NASA Astrophysics Data System (ADS)

    Lindsay, Geoffrey A.; Ashley, Paul R.; Guenther, Andrew P.; Sanghadasa, Mohan

    2005-09-01

    This is a brief overview of the technology of nonlinear optical polymers (NLOP) and their use in electro-optic (EO) modulators. This paper also covers preliminary results from the authors' laboratories on highly active CLD- and FTC-type chromophores in guest-host films of APC amorphous polycarbonate. Emphasis will be given to thermal stability and long-term EO modulator aging.

  11. EOS production on the Space Station. [Electrophoresis Operations/Space

    NASA Technical Reports Server (NTRS)

    Runge, F. C.; Gleason, M.

    1986-01-01

    The paper discusses a conceptual integration of the equipment for EOS (Electrophoresis Operations/Space) on the Space Station in the early 1990s. Electrophoresis is a fluid-constituent separation technique which uses forces created by an electrical field. Aspects covered include EOS equipment and operations, and Space Station installations involving a pressurized module, a resupply module, utility provisions and umbilicals and crew involvement. Accommodation feasibility is generally established, and interfaces are defined. Space Station production of EOS-derived pharmaceuticals will constitute a significant increase in capability compared to precursor flights on the Shuttle in the 1980s.

  12. From Physics to industry: EOS outside HEP

    NASA Astrophysics Data System (ADS)

    Espinal, X.; Lamanna, M.

    2017-10-01

    In the competitive market for large-scale storage solutions the current main disk storage system at CERN EOS has been showing its excellence in the multi-Petabyte high-concurrency regime. It has also shown a disruptive potential in powering the service in providing sync and share capabilities and in supporting innovative analysis environments along the storage of LHC data. EOS has also generated interest as generic storage solution ranging from university systems to very large installations for non-HEP applications.

  13. EOS ODL Metadata On-line Viewer

    NASA Astrophysics Data System (ADS)

    Yang, J.; Rabi, M.; Bane, B.; Ullman, R.

    2002-12-01

    We have recently developed and deployed an EOS ODL metadata on-line viewer. The EOS ODL metadata viewer is a web server that takes: 1) an EOS metadata file in Object Description Language (ODL), 2) parameters, such as which metadata to view and what style of display to use, and returns an HTML or XML document displaying the requested metadata in the requested style. This tool is developed to address widespread complaints by science community that the EOS Data and Information System (EOSDIS) metadata files in ODL are difficult to read by allowing users to upload and view an ODL metadata file in different styles using a web browser. Users have the selection to view all the metadata or part of the metadata, such as Collection metadata, Granule metadata, or Unsupported Metadata. Choices of display styles include 1) Web: a mouseable display with tabs and turn-down menus, 2) Outline: Formatted and colored text, suitable for printing, 3) Generic: Simple indented text, a direct representation of the underlying ODL metadata, and 4) None: No stylesheet is applied and the XML generated by the converter is returned directly. Not all display styles are implemented for all the metadata choices. For example, Web style is only implemented for Collection and Granule metadata groups with known attribute fields, but not for Unsupported, Other, and All metadata. The overall strategy of the ODL viewer is to transform an ODL metadata file to a viewable HTML in two steps. The first step is to convert the ODL metadata file to an XML using a Java-based parser/translator called ODL2XML. The second step is to transform the XML to an HTML using stylesheets. Both operations are done on the server side. This allows a lot of flexibility in the final result, and is very portable cross-platform. Perl CGI behind the Apache web server is used to run the Java ODL2XML, and then run the results through an XSLT processor. The EOS ODL viewer can be accessed from either a PC or a Mac using Internet

  14. Evaluation of Ophthalmic Surgical Instrument Sterility Using Short-Cycle Sterilization for Sequential Same-Day Use.

    PubMed

    Chang, David F; Hurley, Nikki; Mamalis, Nick; Whitman, Jeffrey

    2018-03-27

    The common practice of short-cycle sterilization for ophthalmic surgical instrumentation has come under increased regulatory scrutiny. This study was undertaken to evaluate the efficacy of short-cycle sterilization processing for consecutive same-day cataract procedures. Testing of specific sterilization processing methods by an independent medical device validation testing laboratory. Phaco handpieces from 3 separate manufacturers were tested along with appropriate biologic indicators and controls using 2 common steam sterilizers. A STATIM 2000 sterilizer (SciCan, Canonsburg, PA) with the STATIM metal cassette, and an AMSCO Century V116 pre-vacuum sterilizer (STERIS, Mentor, OH) using a Case Medical SteriTite container (Case Medical, South Hackensack, NJ) rigid container were tested using phaco tips and handpieces from 3 different manufacturers. Biological indicators were inoculated with highly resistant Geobacillus stearothermophilus, and each sterility verification test was performed in triplicate. Both wrapped and contained loads were tested with full dry cycles and a 7-day storage time to simulate prolonged storage. In adherence with the manufacturers' instructions for use (IFU), short cycles (3.0-3.5-minute exposure times) for unwrapped and contained loads were also tested after only 1 minute of dry time to simulate use on a consecutive case. Additional studies were performed to demonstrate whether any moisture present in the load containing phaco handpieces postprocessing was sterile and would affect the sterility of the contents after a 3-minute transit/storage time. This approximated the upper limit of time needed to transfer a containment device to the operating room. Presence or absence of microbial growth from cultured test samples. All inoculated test samples from both sterilizers were negative for growth of the target organism whether the full dry phase was interrupted or not. Pipetted postprocessing moisture samples and swabs of the handpieces were

  15. Realtime Decision Making on EO-1 Using Onboard Science Analysis

    NASA Technical Reports Server (NTRS)

    Sherwood, Robert; Chien, Steve; Davies, Ashley; Mandl, Dan; Frye, Stu

    2004-01-01

    Recent autonomy experiments conducted on Earth Observing 1 (EO-1) using the Autonomous Sciencecraft Experiment (ASE) flight software has been used to classify key features in hyperspectral images captured by EO-1. Furthermore, analysis is performed by this software onboard EO-1 and then used to modify the operational plan without interaction from the ground. This paper will outline the overall operations concept and provide some details and examples of the onboard science processing, science analysis, and replanning.

  16. Preparation of sterile xenon-133 in saline for tissue perfusion studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiPiazza, H.J.; Harbert, J.C.

    1983-11-01

    A simple, inexpensive method of obtaining Xe-133 in sterile saline is presented. The method uses commercial xenon ampules supplied for pulmonary ventilation studies. As much as 10% of the gas activity can be recovered per aliquot by cooling the saline to 4/sup 0/C. The specific activities obtained are adequate for most tissue perfusion studies.

  17. A watershed model to integrate EO data

    NASA Astrophysics Data System (ADS)

    Jauch, Eduardo; Chambel-Leitao, Pedro; Carina, Almeida; Brito, David; Cherif, Ines; Alexandridis, Thomas; Neves, Ramiro

    2013-04-01

    MOHID LAND is a open source watershed model developed by MARETEC and is part of the MOHID Framework. It integrates four mediums (or compartments): porous media, surface, rivers and atmosphere. The movement of water between these mediums are based on mass and momentum balance equations. The atmosphere medium is not explicity simulated. Instead, it's used as boundary condition to the model through meteorological properties: precipitation, solar radiation, wind speed/direction, relative humidity and air temperature. The surface medium includes the overland runoff and vegetation growth processes and is simulated using a 2D grid. The porous media includes both the unsaturated (soil) and saturated zones (aquifer) and is simulated using a 3D grid. The river flow is simulated through a 1D drainage network. All these mediums are linked through evapotranspiration and flow exchanges (infiltration, river-soil growndwater flow, surface-river overland flow). Besides the water movement, it is also possible to simulate water quality processes and solute/sediment transport. Model setup include the definition of the geometry and the properties of each one of its compartments. After the setup of the model, the only continuous input data that MOHID LAND requires are the atmosphere properties (boundary conditions) that can be provided as timeseries or spacial data. MOHID LAND has been adapted the last 4 years under FP7 and ESA projects to integrate Earth Observation (EO) data, both variable in time and in space. EO data can be used to calibrate/validate or as input/assimilation data to the model. The currently EO data used include LULC (Land Use Land Cover) maps, LAI (Leaf Area Index) maps, EVTP (Evapotranspiration) maps and SWC (Soil Water Content) maps. Model results are improved by the EO data, but the advantage of this integration is that the model can still run without the EO data. This means that model do not stop due to unavailability of EO data and can run on a forecast mode

  18. Production of a sterile species via active-sterile mixing: An exactly solvable model

    NASA Astrophysics Data System (ADS)

    Boyanovsky, D.

    2007-11-01

    The production of a sterile species via active-sterile mixing in a thermal medium is studied in an exactly solvable model. The exact time evolution of the sterile distribution function is determined by the dispersion relations and damping rates Γ1,2 for the quasiparticle modes. These depend on γ˜=Γaa/2ΔE, with Γaa the interaction rate of the active species in absence of mixing and ΔE the oscillation frequency in the medium without damping. γ˜≪1, γ˜≫1 describe the weak and strong damping limits, respectively. For γ˜≪1, Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where θm is the mixing angle in the medium and the sterile distribution function does not obey a simple rate equation. For γ˜≫1, Γ1=Γaa and Γ2=Γaasin⁡22θm/4γ˜2, is the sterile production rate. In this regime sterile production is suppressed and the oscillation frequency vanishes at an Mikheyev-Smirnov-Wolfenstein (MSW) resonance, with a breakdown of adiabaticity. These are consequences of quantum Zeno suppression. For active neutrinos with standard model interactions the strong damping limit is only available near an MSW resonance if sin⁡2θ≪αw with θ the vacuum mixing angle. The full set of quantum kinetic equations for sterile production for arbitrary γ˜ are obtained from the quantum master equation. Cosmological resonant sterile neutrino production is quantum Zeno suppressed relieving potential uncertainties associated with the QCD phase transition.

  19. Surgical sterilization: an underutilized procedure for evaluating the merits of induced sterility

    USGS Publications Warehouse

    Kennelly, James J.; Converse, Kathryn A.

    1993-01-01

    Despite more than 4 decades of effort, development of effective wildlife damage control programs based on sterilization of target species has met with limited success. This is partly due to the fact that investigators have assumed, rather than empirically tested, whether the reproductive strategies of the target populations were vulnerable to the planned treatment. Equally important, methods selected to include sterility usually involve a chemical agent that can affect sociosexual behaviors of the nuisance population. In this report, we illustrate how surgically induced sterility circumvents both problems--how the concept without the potentially confounding secondary effects of a chemical. We assessed the merits of initiating research to develop a male chemosterilant for Norway rats, red-winged blackbirds, beaver, and Canada geese by inducing sterility surgically. The infidelity of many red-winged females to their polygynous territorial male was surprising and argued against searching for a male sterilant. On the other hand, beaver and Canada goose studies confirmed previous reports that both form par-bonds and are monogamous. Both should be vulnerable to a male chemosterilant approach, and research toward this goal is justified.

  20. 2016 Mission Operations Working Group: Earth Observing-1 (EO-1)

    NASA Technical Reports Server (NTRS)

    Frye, Stuart

    2016-01-01

    EO-1 Mission Status for the Constellation Mission Operations Working Group to discuss the EO-1 flight systems, mission enhancements, debris avoidance maneuver, orbital information, 5-year outlook, and new ground stations.

  1. Monitor for Sterilization Procedures

    DTIC Science & Technology

    2001-10-25

    were tested using ampules of Bacillus stearothermophilus spores commercially manufactured by Barnstead/Thermolyne for testing sterilization procedures...Monitor for Sterilization Procedures F. Cleary1,2, H.-Y. Mason2, C. Estes2, A. Duncan2, W. Ellis, Jr.2 and L. Powers2 1Moses Brown High School...accurate determination of the efficacy of sterilization procedures is demonstrated using a hand-held instrument based on the intrinsic fluorescence of

  2. Bioavailability of five hydrophobic organic compounds to earthworms from sterile and non-sterile artificial soils.

    PubMed

    Šmídová, Klára; Kim, Sooyeon; Hofman, Jakub

    2017-07-01

    Bioaccumulation factors (BAFs) of organic pollutants to soil biota, often required by risk assessment, are mostly obtained in non-sterile laboratory-contaminated artificial soils. However, microbial degradation has been indicated by many authors to influence the fate of hydrophobic organic compounds (HOCs) in soils. A question arises if the microbial community of peat which is used for artificial soil preparation affects the measured values of BAFs. In this study the effect of soil microorganisms on bioavailability of HOCs was studied and a portion of each soil was sterilized by gamma irradiation. Results indicated that the sterilization process significantly affected the fate of polycyclic aromatic hydrocarbons (PAHs; phenanthrene and pyrene) and increased bioavailability of these compounds to earthworms with BAFs several times higher in the sterile soils compared to their non-sterile variants. This suggests that sterilization of soils can be used as the "worst-case scenario" for laboratory tests of toxicity or bioaccumulation of biodegradable HOCs such as PAHs. It represents a situation of limited microbial degradation resulting in higher bioavailable fractions to other organisms (e.g. invertebrates). This may be the case in soils where microbial communities face stresses caused by contamination or land management. The bioavailability of chlorinated HOCs (lindane, 4,4'-DDT and PCB 153) was not affected by sterilization, as their BAFs were similar in the sterile and non-sterile soils during the experiment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Sterility maintenance study: Dynamic evaluation of sterilized rigid containers and wrapped instrument trays to prevent bacterial ingress.

    PubMed

    Shaffer, Harry L; Harnish, Delbert A; McDonald, Michael; Vernon, Reid A; Heimbuch, Brian K

    2015-12-01

    Sterilized packaging systems are designed to maintain the sterility of surgical instruments and devices from the time of sterilization until use. This study evaluated the effectiveness of rigid containers versus wrapped instrument trays, sterilized using North American sterilization protocols, to maintain a sterile internal environment poststerilization when challenged with aerosolized bacteria under dynamic environmental conditions. Using a custom aerosol chamber, 111 rigid containers of various durations of use (unused, used <5 years, used 5-9 years) and 161 wrapped trays using 3 grades of sterilization wrap were challenged with ~10(2) colony-forming units per liter of air containing aerosolized Micrococcus luteus with a count median particle size of 1 μm, while simultaneously experiencing air volume exchanges due to vacuum cycles-two 1-psi cycles, three 0.7-psi cycles, and three 0.4-psi cycles-to simulate air exchange events occurring during the sterilization, transportation, and storage of sterilized instrument trays in health care facilities. Of 111 rigid containers tested, 97 (87%) demonstrated bacterial ingress into the container. Of 161 wrapped trays, 0 (0%) demonstrated bacterial ingress into the tray. Contamination rates of rigid containers increased significantly with increasing duration of use. In this study using a dynamic bacterial aerosol challenge, sterilized wrapped trays demonstrated significantly greater protection than sterilized rigid containers against the ingress of airborne bacteria. Copyright © 2015. Published by Elsevier Inc.

  4. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America.

    PubMed

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35-13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker training on HIV and reproductive rights

  5. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America

    PubMed Central

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Introduction Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Methods Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. Results A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35–13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. Conclusions The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker

  6. Optimizing sterilization logistics in hospitals.

    PubMed

    van de Klundert, Joris; Muls, Philippe; Schadd, Maarten

    2008-03-01

    This paper deals with the optimization of the flow of sterile instruments in hospitals which takes place between the sterilization department and the operating theatre. This topic is especially of interest in view of the current attempts of hospitals to cut cost by outsourcing sterilization tasks. Oftentimes, outsourcing implies placing the sterilization unit at a larger distance, hence introducing a longer logistic loop, which may result in lower instrument availability, and higher cost. This paper discusses the optimization problems that have to be solved when redesigning processes so as to improve material availability and reduce cost. We consider changing the logistic management principles, use of visibility information, and optimizing the composition of the nets of sterile materials.

  7. Eugenics and Involuntary Sterilization: 1907-2015.

    PubMed

    Reilly, Philip R

    2015-01-01

    In England during the late nineteenth century, intellectuals, especially Francis Galton, called for a variety of eugenic policies aimed at ensuring the health of the human species. In the United States, members of the Progressive movement embraced eugenic ideas, especially immigration restriction and sterilization. Indiana enacted the first eugenic sterilization law in 1907, and the US Supreme Court upheld such laws in 1927. State programs targeted institutionalized, mentally disabled women. Beginning in the late 1930s, proponents rationalized involuntary sterilization as protecting vulnerable women from unwanted pregnancy. By World War II, programs in the United States had sterilized approximately 60,000 persons. After the horrific revelations concerning Nazi eugenics (German Hereditary Health Courts approved at least 400,000 sterilization operations in less than a decade), eugenic sterilization programs in the United States declined rapidly. Simplistic eugenic thinking has faded, but coerced sterilization remains widespread, especially in China and India. In many parts of the world, involuntary sterilization is still intermittently used against minority groups.

  8. Evaluation of Penicillium digitatum sterilization using non-equilibrium atmospheric pressure plasma by terahertz time-domain spectroscopy

    NASA Astrophysics Data System (ADS)

    Hiraoka, Takehiro; Ebizuka, Noboru; Takeda, Keigo; Ohta, Takayuki; Kondo, Hiroki; Ishikawa, Kenji; Kawase, Kodo; Ito, Masafumi; Sekine, Makoto; Hori, Masaru

    2011-10-01

    Recently, the plasma sterilization has attracted much attention as a new sterilization technique that takes the place of spraying agricultural chemicals. The conventional methods for sterilization evaluation, was demanded to culture the samples for several days after plasma treatment. Then, we focused on Terahertz time-domain spectroscopy (THz-TDS). At the THz region, vibrational modes of biological molecules and fingerprint spectra of biologically-relevant molecules were also observed. In this study, our purpose was measurement of the fingerprint spectrum of the Penicillium digitatum (PD) spore and establishment of sterilization method by THz-TDS. The sample was 40mg/ml PD spore suspensions which dropped on cover glass. The atmospheric pressure plasma generated under the conditions which Ar gas flow was 3slm, and alternating voltage of 6kV was applied. The samples were exposed the plasma from 10mm distance for 10 minutes. We could obtain the fingerprint spectrum of the PD spore from 0.5 to 0.9THz. This result indicated the possibility of in-situ evaluation for PD sterilization using THz-TDS.

  9. Applications of the EOS SAR to monitoring global change

    NASA Technical Reports Server (NTRS)

    Schier, Marguerite; Way, Jobea; Holt, Benjamin

    1991-01-01

    The SAR employed by NASA's Earth Observing System (EOS) is a multifrequency multipolarization radar which can conduct global monitoring of geophysical and biophysical parameters. The present discussion of the EOS SAR's role in global monitoring emphasizes geophysical product variables applicable to global hydrologic, biogeochemical, and energy cycle models. EOS SAR products encompass biomass, wetland areas, and phenologic and environmental states, in the field of ecosystem dynamics; soil moisture, snow moisture and extent, and glacier and ice sheet extent and velocity, in hydrologic cycle studies; surface-wave fields and sea ice properties, in ocean/atmosphere circulation; and the topography, erosion, and land forms of the solid earth.

  10. Eos and the Youth: A Case of Inverted Roles in Rape

    NASA Astrophysics Data System (ADS)

    Dipla, Anthi

    This article examines scenes of Eos pursuing/abducting youths on 5th-century Athenian vases. Eos, the personification of Dawn, is the only woman assuming the role of a pursuer in rape. The theme strangely becomes very popular with vase painters to a degree comparable to ephebes pursuing a woman. The iconography of the scenes is systematically analysed and evaluated. All theories explaining the popularity of the theme from its presumable use as a parable for death are considered. Eos is moreover compared to other winged figures in pursuit that are popular in the same period, especially Sphinx and Eros. Conversely, it is illustrated how Eos' pursuits of youths are thoroughly coined on the same model as ephebe rape scenes. These may have been so popular because they expressed prevalent social notions about how women, like animals,would need subduing/taming by the ephebe, future citizen hunters, before they could assume their appropriate place in society. With Eos the hunter becomes the prey of a wild woman, who has transgressed the control limits set by the social system. Eos is promoted as the ultimate model of what a woman should not be.

  11. Sterile neutrinos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kopp, J.; Machado, P. A. N., E-mail: pedro.machado@uam.es; Instituto de Física Teórica UAM/CSIC, Calle Nicolás Cabrera 13-15, Cantoblanco E-28049 Madrid

    2016-06-21

    We characterize statistically the indications of a presence of one or more light sterile neutrinos from MiniBooNE and LSND data, together with the reactor and gallium anomalies, in the global context. The compatibility of the aforementioned signals with null results from solar, atmospheric, reactor, and accelerator experiments is evaluated. We conclude that a severe tension is present in the global fit, and therefore the addition of eV-scale sterile neutrinos does not satisfactorily explain the anomalies.

  12. EOS Terra Validation Program

    NASA Technical Reports Server (NTRS)

    Starr, David

    1999-01-01

    The EOS Terra mission will be launched in July 1999. This mission has great relevance to the atmospheric radiation community and global change issues. Terra instruments include ASTER, CERES, MISR, MODIS and MOPITT. In addition to the fundamental radiance data sets, numerous global science data products will be generated, including various Earth radiation budget, cloud and aerosol parameters, as well as land surface, terrestrial ecology, ocean color, and atmospheric chemistry parameters. Significant investments have been made in on-board calibration to ensure the quality of the radiance observations. A key component of the Terra mission is the validation of the science data products. This is essential for a mission focused on global change issues and the underlying processes. The Terra algorithms have been subject to extensive pre-launch testing with field data whenever possible. Intensive efforts will be made to validate the Terra data products after launch. These include validation of instrument calibration (vicarious calibration) experiments, instrument and cross-platform comparisons, routine collection of high quality correlative data from ground-based networks, such as AERONET, and intensive sites, such as the SGP ARM site, as well as a variety field experiments, cruises, etc. Airborne simulator instruments have been developed for the field experiment and underflight activities including the MODIS Airborne Simulator (MAS), AirMISR, MASTER (MODIS-ASTER), and MOPITT-A. All are integrated on the NASA ER-2, though low altitude platforms are more typically used for MASTER. MATR is an additional sensor used for MOPITT algorithm development and validation. The intensive validation activities planned for the first year of the Terra mission will be described with emphasis on derived geophysical parameters of most relevance to the atmospheric radiation community. Detailed information about the EOS Terra validation Program can be found on the EOS Validation program

  13. [Patient information prior to sterilization].

    PubMed

    Rasmussen, O V; Henriksen, L O; Baldur, B; Hansen, T

    1992-09-14

    The law in Denmark prescribes that the patient and the general practitioner to whom the patient directs his or her request for sterilization are obliged to confirm by their signatures that the patient has received information about sterilization, its risk and consequences. We asked 97 men and 96 women, if they had received this information prior to their sterilization. They were also asked about their knowledge about sterilization. 54% of the women and 35% of the men indicated that they had not received information. Only few of these wished further information by the hospital doctor. Knowledge about sterilization was good. It is concluded that the information to the patient prior to sterilization is far from optimal. The patients' signature confirming verbal information is not a sufficient safeguard. We recommend, among other things, that the patient should receive written information and that both the general practitioner and the hospital responsible for the operation should ensure that optimal information is received by the patient.

  14. The EOS CERES Global Cloud Mask

    NASA Technical Reports Server (NTRS)

    Berendes, T. A.; Welch, R. M.; Trepte, Q.; Schaaf, C.; Baum, B. A.

    1996-01-01

    To detect long-term climate trends, it is essential to produce long-term and consistent data sets from a variety of different satellite platforms. With current global cloud climatology data sets, such as the International Satellite Cloud Climatology Experiment (ISCCP) or CLAVR (Clouds from Advanced Very High Resolution Radiometer), one of the first processing steps is to determine whether an imager pixel is obstructed between the satellite and the surface, i.e., determine a cloud 'mask.' A cloud mask is essential to studies monitoring changes over ocean, land, or snow-covered surfaces. As part of the Earth Observing System (EOS) program, a series of platforms will be flown beginning in 1997 with the Tropical Rainfall Measurement Mission (TRMM) and subsequently the EOS-AM and EOS-PM platforms in following years. The cloud imager on TRMM is the Visible/Infrared Sensor (VIRS), while the Moderate Resolution Imaging Spectroradiometer (MODIS) is the imager on the EOS platforms. To be useful for long term studies, a cloud masking algorithm should produce consistent results between existing (AVHRR) data, and future VIRS and MODIS data. The present work outlines both existing and proposed approaches to detecting cloud using multispectral narrowband radiance data. Clouds generally are characterized by higher albedos and lower temperatures than the underlying surface. However, there are numerous conditions when this characterization is inappropriate, most notably over snow and ice of the cloud types, cirrus, stratocumulus and cumulus are the most difficult to detect. Other problems arise when analyzing data from sun-glint areas over oceans or lakes over deserts or over regions containing numerous fires and smoke. The cloud mask effort builds upon operational experience of several groups that will now be discussed.

  15. EOS Laser Atmosphere Wind Sounder (LAWS) investigation

    NASA Technical Reports Server (NTRS)

    Emmitt, George D.

    1991-01-01

    The related activities of the contract are outlined for the first year. These include: (1) attend team member meetings; (2) support EOS Project with science related activities; (3) prepare and Execution Phase plan; and (4) support LAWS and EOSDIS related work. Attached to the report is an appendix, 'LAWS Algorithm Development and Evaluation Laboratory (LADEL)'. Also attached is a copy of a proposal to the NASA EOS for 'LAWS Sampling Strategies and Wind Computation Algorithms -- Storm-Top Divergence Studies. Volume I: Investigation and Technical Plan, Data Plan, Computer Facilities Plan, Management Plan.'

  16. Limitations of Thioglycolate Broth as a Sterility Test Medium for Materials Exposed to Gaseous Ethylene Oxide1

    PubMed Central

    Doyle, John E.; Mehrhof, William H.; Ernst, Robert R.

    1968-01-01

    Although ethylene oxide is a reliable sterilizer, the process may be limited by diffusion. Thus, situations may exist where microorganisms are protected from the sterilizing gas. It is possible that the exterior of a substance may be sterilized, whereas the interior is not. We investigated three general types of materials in which this limitation of diffusion could occur: the bore of glass and plastic tubing, the center of cotton balls, and plastic adhesive film/paper backing interface. These materials were contaminated as close to their geometric center as possible with Bacillus subtilis var. niger spores occluded in crystals of sodium chloride. After exposure of the contaminated materials (except aluminum foil) to ethylene oxide, thioglycolate broth (a standard sterility-test medium) indicated sterility, whereas Trypticase Soy Broth indicated nonsterility. It is likewise possible that aerobic microorganisms, surviving in or on material after exposure to dry heat or steam sterilization processes, would not be recovered by thioglycollate broth. Entrapped aerobic organisms will probably not grow out in the low oxygen tension zone of an anaerobic medium such as thioglycollate broth. It is recommended than an aerobic medium such as Trypticase Soy Broth be used concurrently with thioglycolate broth for sterility testing. PMID:4973064

  17. The Integration, Testing and Flight of the EO-1 GPS

    NASA Technical Reports Server (NTRS)

    Quinn, David A.; Sanneman, Paul A.; Shulman, Seth E.; Sager, Jennifer A.

    2001-01-01

    The Global Positioning System has long been hailed as the wave of the future for autonomous on-board navigation of low Earth orbiting spacecraft despite the fact that relatively few spacecraft have actually employed it for this purpose. While several missions operated out of the Goddard Space Flight Center have flown GPS receivers on board, the New Millenium Program (NMP) Earth Orbiting-1 (EO-1) spacecraft is the first to employ GPS for active, autonomous on-board navigation. Since EO-1 was designed to employ GPS as its primary source of the navigation ephemeris, special care had to be taken during the integration phase of spacecraft construction to assure proper performance. This paper is a discussion of that process: a brief overview of how the GPS works, how it fits into the design of the EO-1 Attitude Control System (ACS), the steps taken to integrate the system into the EO-1 spacecraft, the ultimate on-orbit performance during launch and early operations of the EO-1 mission and the performance of the on-board GPS ephemeris versus the ground based ephemeris. Conclusions will include a discussion of the lessons learned.

  18. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam. (b...

  19. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  20. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 1 2014-10-01 2014-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare Department of Health and Human Services GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  1. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 1 2011-10-01 2011-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  2. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 1 2013-10-01 2013-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  3. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 1 2012-10-01 2012-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  4. New disinfection and sterilization methods.

    PubMed Central

    Rutala, W. A.; Weber, D. J.

    2001-01-01

    New disinfection methods include a persistent antimicrobial coating that can be applied to inanimate and animate objects (Surfacine), a high-level disinfectant with reduced exposure time (ortho-phthalaldehyde), and an antimicrobial agent that can be applied to animate and inanimate objects (superoxidized water). New sterilization methods include a chemical sterilization process for endoscopes that integrates cleaning (Endoclens), a rapid (4-hour) readout biological indicator for ethylene oxide sterilization (Attest), and a hydrogen peroxide plasma sterilizer that has a shorter cycle time and improved efficacy (Sterrad 50). PMID:11294738

  5. Observational constraints on Hubble parameter in viscous generalized Chaplygin gas

    NASA Astrophysics Data System (ADS)

    Thakur, P.

    2018-04-01

    Cosmological model with viscous generalized Chaplygin gas (in short, VGCG) is considered here to determine observational constraints on its equation of state parameters (in short, EoS) from background data. These data consists of H(z)-z (OHD) data, Baryonic Acoustic Oscillations peak parameter, CMB shift parameter and SN Ia data (Union 2.1). Best-fit values of the EoS parameters including present Hubble parameter (H0) and their acceptable range at different confidence limits are determined. In this model the permitted range for the present Hubble parameter and the transition redshift (zt) at 1σ confidence limits are H0= 70.24^{+0.34}_{-0.36} and zt=0.76^{+0.07}_{-0.07} respectively. These EoS parameters are then compared with those of other models. Present age of the Universe (t0) have also been determined here. Akaike information criterion and Bayesian information criterion for the model selection have been adopted for comparison with other models. It is noted that VGCG model satisfactorily accommodates the present accelerating phase of the Universe.

  6. Pain Associated With Hysteroscopic Sterilization

    PubMed Central

    Levy, Jenna; Childers, Meredith E.

    2007-01-01

    Background and Objectives: The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. Methods: Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks post-procedure. Results: The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=−8.17, P<.0001). One-week post-procedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t =−9.67, P<.0001). Four weeks post-procedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=−3.04, P=.004). Conclusions: Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control. PMID:17651558

  7. Implementing AORN recommended practices for sterilization.

    PubMed

    Graybill-D'Ercole, Patricia

    2013-05-01

    Any hospital or facility in which surgery and other invasive procedures are performed should have accommodations for cleaning, decontaminating, disinfecting, and sterilizing instruments, equipment, and other essential supplies that are used for patient procedures. Sterilization is essential to reducing or preventing the risk of surgical site infections. This is a collaborative process and should include all health care providers who handle these instruments, including perioperative nurses. The revised AORN "Recommended practices for sterilization," which became effective June 15, 2012, includes updates on sterilizing single-use items, inspecting critical items before sterilization, using low-temperature hydrogen peroxide vapor sterilization methods, and immediate use steam sterilization. This RP document is the first AORN document to be evidence rated and accepted for inclusion in the Agency for Healthcare Research and Quality National Guideline Clearinghouse. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  8. Recent disruption of an asteroid from the Eos family

    NASA Astrophysics Data System (ADS)

    Novaković, B.; Tsirvoulis, G.

    2014-07-01

    A key difficulty with searching for partially differentiated asteroids arises from the fact that a crust covers the exterior of the body, and, consequently, should hide the melted interior. This motivates an alternative approach of examining members of asteroid families, i.e., fragments of single large bodies, many of which were in the size regime capable of igneous differentiation, that have been disrupted by catastrophic collisions. Such families could provide a stratigraphic cross section across the interior of the parent asteroid [1]. With more than 10,000 known members, the Eos dynamical family is one of the most numerous and earliest recognized asteroid families [2]. Interestingly, the estimated ˜220-km-diameter parent body [3] is well within the size range capable of differentiation. Thus, existing family members should contain fragments of the deep interior. The Eos family has the highest diversity of taxonomic classes than any other known family [4]. Many members are of K spectral type, which is uncommon outside the family, and is similar to the spectra of CV, CK, CO, and CR carbonaceous chondrites [5]. This diversity leads to the suggestion that the Eos parent body was partially differentiated [4,6]. Thus, the Eos family may not only be a remnant of a partially differentiated parent body, but it could be the source of the CV-CK meteorite group. Here we report the discovery of a young subfamily of the Eos asteroid family. It may help understanding the mineralogical nature of the Eos asteroid family and of its parent body. By applying the hierarchical clustering method [7], we find an extremely compact 16-body cluster within the borders of the Eos family. We name the cluster (6733) 1992 EF, after its largest member. The statistical significance of this new cluster is estimated to be above 99%, indicating that its members share a common origin. All members of the cluster are found to be dynamically stable over long timescales. Backward numerical orbital

  9. Review of surface steam sterilization for validation purposes.

    PubMed

    van Doornmalen, Joost; Kopinga, Klaas

    2008-03-01

    Sterilization is an essential step in the process of producing sterile medical devices. To guarantee sterility, the process of sterilization must be validated. Because there is no direct way to measure sterility, the techniques applied to validate the sterilization process are based on statistical principles. Steam sterilization is the most frequently applied sterilization method worldwide and can be validated either by indicators (chemical or biological) or physical measurements. The steam sterilization conditions are described in the literature. Starting from these conditions, criteria for the validation of steam sterilization are derived and can be described in terms of physical parameters. Physical validation of steam sterilization appears to be an adequate and efficient validation method that could be considered as an alternative for indicator validation. Moreover, physical validation can be used for effective troubleshooting in steam sterilizing processes.

  10. Sterilization of Long Tube Inner Surface Using Oxygen and Water Vapor Plasmas Produced by AC HV Discharge

    NASA Astrophysics Data System (ADS)

    Kitazaki, Satoshi; Hayashi, Nobuya

    2009-10-01

    Oxygen and water vapor plasmas inside a narrow long tube were produced using an AC HV glow discharge at low pressure in order to sterilize the inner surface of a tube. In order to produce plasma inside a narrow tube, an AC high voltage was adopted. The material of the tube used in this experiment was silicon rubber. The length and diameter of the tubes ranged from 300 to 1,000 mm and from 1 to 4 mm, respectively. The tube was placed in a stainless steel vacuum chamber and was evacuated to 10 Pa using a rotary pump. The material gas for plasma and radical productions was pure oxygen or water vapor, which was introduced to the chamber from a gas cylinder or water reservoir. Light emission spectral lines of oxygen and OH radicals were observed at 777 nm and 306 nm, respectively. The chemical indicator was inserted into the tube and turned to a yellowish color (from the original red) after a treatment, which indicates the generation of sufficient oxygen on OH radicals for sterilization. A tube with the length of 500 mm and diameter of 4 mm is sterilized using oxygen plasma by 10 minutes treatment. Also a tube with the length of 300 mm and diameter of 2 mm is sterilized using water vapor plasma by 5 minutes treatment.

  11. Eosinophilic Esophagitis in Children and Adolescents with Abdominal Pain: Comparison with EoE-Dysphagia and Functional Abdominal Pain.

    PubMed

    Gunasekaran, Thirumazhisai; Prabhakar, Gautham; Schwartz, Alan; Gorla, Kiranmai; Gupta, Sandeep; Berman, James

    2016-01-01

    Aim. Compare EoE-AP with EoE-D for clinical, endoscopy (EGD), histology and outcomes and also with FAP-N. Method. Symptoms, physical findings, EGD, histology, symptom scores, and treatments were recorded for the three groups. Cluster analysis was done. Results. Dysphagia and abdominal pain were different in numbers but not statistically significant between EoE-AP and EoE-D. EGD, linear furrows, white exudates were more in the EoE-D and both combined were significant (p < 0.05). EoE-D, peak and mean eosinophils (p  0.06) and eosinophilic micro abscesses (p  0.001) were higher. Follow-Up. Based on single symptom, EoE-AP had 30% (p  0.25) improvement, EoE-D 86% (p < 0.001) and similar with composite score (p  0.57 and <0.001, resp.). Patients who had follow-up, EGD: 42.8% with EoE-AP and 77.8% with EoE-D, showed single symptom improvement and the eosinophil count fell from 38.5/34.6 (peak and mean) to 31.2/30.4 (p  0.70) and from 43.6/40.8 to 25.2/22.8 (p < 0.001), respectively. FAP-N patients had similar symptom improvement like EoE-D. Cluster Analysis. EoE-AP and FAP-N were similar in clinical features and response to treatment, but EoE-D was distinctly different from EoE-AP and FAP-N. Conclusion. Our study demonstrates that EoE-AP and EoE-D have different histology and outcomes. In addition, EoE-AP has clinical features similar to the FAP-N group.

  12. Eosinophilic Esophagitis in Children and Adolescents with Abdominal Pain: Comparison with EoE-Dysphagia and Functional Abdominal Pain

    PubMed Central

    Gorla, Kiranmai; Gupta, Sandeep

    2016-01-01

    Aim. Compare EoE-AP with EoE-D for clinical, endoscopy (EGD), histology and outcomes and also with FAP-N. Method. Symptoms, physical findings, EGD, histology, symptom scores, and treatments were recorded for the three groups. Cluster analysis was done. Results. Dysphagia and abdominal pain were different in numbers but not statistically significant between EoE-AP and EoE-D. EGD, linear furrows, white exudates were more in the EoE-D and both combined were significant (p < 0.05). EoE-D, peak and mean eosinophils (p  0.06) and eosinophilic micro abscesses (p  0.001) were higher. Follow-Up. Based on single symptom, EoE-AP had 30% (p  0.25) improvement, EoE-D 86% (p < 0.001) and similar with composite score (p  0.57 and <0.001, resp.). Patients who had follow-up, EGD: 42.8% with EoE-AP and 77.8% with EoE-D, showed single symptom improvement and the eosinophil count fell from 38.5/34.6 (peak and mean) to 31.2/30.4 (p  0.70) and from 43.6/40.8 to 25.2/22.8 (p < 0.001), respectively. FAP-N patients had similar symptom improvement like EoE-D. Cluster Analysis. EoE-AP and FAP-N were similar in clinical features and response to treatment, but EoE-D was distinctly different from EoE-AP and FAP-N. Conclusion. Our study demonstrates that EoE-AP and EoE-D have different histology and outcomes. In addition, EoE-AP has clinical features similar to the FAP-N group. PMID:27610357

  13. Earth Observation Training and Education with ESA LearnEO!

    NASA Astrophysics Data System (ADS)

    Byfield, Valborg; Mathieu, Pierre-Philippe; Dobson, Malcolm; Rosmorduc, Vinca; Del Frate, Fabio; Banks, Chris; Picchiani, Matteo

    2013-04-01

    For society to benefit fully from its investment in Earth observation, EO data must be accessible and familiar to a global community of users who have the skills, knowledge and understanding to use the observations appropriately in their work. Achieving this requires considerable education effort. LearnEO! (www.learn-eo.org) is a new ESA education project that contributes towards making this a reality. LearnEO! has two main aims: to develop new training resources that use data from sensors on ESA satellites to explore a variety of environmental topics, and to stimulate and support members of the EO and education communities who may be willing to develop and share new education resources in the future. The project builds on the UNESCO Bilko project, which currently supplies free software, tutorials, and example data to users in 175 countries. Most of these users are in academic education or research, but the training resources are also of interest to a growing number of professionals in government, NGOs and private enterprise. Typical users are not remote sensing experts, but see satellite data as one of many observational tools. They want an easy, low-cost means to process, display and analyse data from different satellite sensors as part of their work in environmental research, monitoring and policy development. Many of the software improvements and training materials developed in LearnEO! are in response to requests from this user community. The LearnEO! tutorial and peer-reviewed lessons are designed to teach satellite data processing and analysis skills at different levels, from beginner to advanced - where advanced lessons requires some previous experience with Earth observation techniques. The materials are aimed at students and professionals in various branches of Earth sciences who have not yet specialised in specific EO technologies. The lessons are suitable for self-study, university courses at undergraduate to MSc level, or for continued professional

  14. 78 FR 28704 - Proposed Collection; Comment Request for Form 8453-EO

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-15

    ... Form 8453-EO, Exempt Organization Declaration and Signature for Electronic Filing. DATES: Written... and Signature for Electronic Filing. OMB Number: 1545-1879. Form Number: 8453-EO. Abstract: Form 8453...

  15. 75 FR 36478 - Proposed Collection; Comment Request for Form 8453-EO

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-25

    ... Form 8453-EO, Exempt Organization Declaration and Signature for Electronic Filing. DATES: Written... Declaration and Signature for Electronic Filing. OMB Number: 1545-1879. Form Number: 8453-EO. Abstract: Form...

  16. Nuclear-cytoplasmic male-sterility in diploid dandelions.

    PubMed

    van der Hulst, R G M; Meirmans, P; van Tienderen, P H; van Damme, J M M

    2004-07-01

    Male-sterility was found in diploid dandelions from two widely separated populations from France, and its inheritance was analysed by crossing a diploid male-sterile dandelion to diploid sexuals and triploid apomicts. Nuclear genetic variation, found in full-sib families, segregated for male-fertility, partial male-sterility, and full male-sterility, and also segregated for small-sized versus normally sized pollen. The crossing results are best explained by a cytoplasmic male-sterility factor in combination with two dominant restorer genes. Involvement of the cytoplasmic male-sterility factor was further investigated by chloroplast haplotyping. Male-sterility was exclusively associated with a rare chloroplast haplotype (designated 16b). This haplotype was found in seven male-sterile plants and one (apparently restored) male-fertile individual but does not occur in 110 co-existing male-fertile plants and not in several hundreds of individuals previously haplotyped. Apomicts with cytoplasmic male sterility were generated in some test crosses. This raises the question as to whether the male sterility found in natural dandelion apomicts, is of cytoplasmic or of nuclear genetic nature. As many breeding systems in Taraxacum are involved in shaping population structure, it will be difficult to predict the evolutionary consequences of nuclear-cytoplasmic male-sterility for this species complex.

  17. Topographic data requirements for EOS global change research

    USGS Publications Warehouse

    Gesch, Dean B.

    1994-01-01

    This document is a result of Earth Observing System Data and Information System (EOSDIS) Version 0 activities of the Land Processes Distributed Active Archive Center at the U.S. Geological Survey's EROS Data Center. A relatively small part of the Version 0 funding provided by NASA is used to address topographic data issues related to EOS. These issues include identifying and improving access to existing sources of topographic data, data generation, facilitating the use of topographic data in global change research by demonstrating derivative products, and inventorying the specific topographic data requirements of EOS investigators. There is a clear need for global topographic data in EOSDIS. Only 10 percent of the global land surface is covered by high-resolution data that are available to the global change science community. Alternative sources for new data exist or have been proposed; however, none of them alone can fulfill the data requirements by the launch of the first EOS platform in 4 years. There is no operational provider of all the source data that are required. Even if appropriate global source data existed, a concerted production effort would be necessary to ensure the existence of the requisite topographic data before EOS launch. Additionally, no funding from NASA or any other agency has been appropriated for a new mapping mission or for other means of data acquisition. This effort to document requirements is an initial step toward understanding the severity of the data shortage. It is well beyond the scope of Version 0 funding and capabilities to provide the required data in the proper timeframe. The shortage of data and the lack of a plan for providing the necessary topographic data through EOSDIS in time for launch are issues that must be addressed by the EOS program.

  18. The sterile inflammatory response

    PubMed Central

    Rock, Kenneth L.; Latz, Eicke; Ontiveros, Fernando; Kono, Hajime

    2015-01-01

    The acute inflammatory response is a double-edged sword. On the one hand it plays a key role in initial host defense particularly against many infections. On the other hand its aim is imprecise and as a consequence, when it is drawn into battle, it can cause collateral damage in tissues. In situations where the inciting stimulus is sterile, the cost-benefit ratio may be high; because of this, sterile inflammation underlies the pathogenesis of a number of diseases. While there have been major advances in our understanding of how microbes trigger inflammation, much less has been learned about this process in sterile situations. This review focuses on a subset of the many sterile stimuli that can induce inflammation – specifically dead cells and a variety of irritant particles, including crystals, minerals, and protein aggregates. Although this subset of stimuli is structurally very diverse and might appear to be unrelated, there is accumulating evidence that the innate immune system may recognize them in similar ways and stimulate the sterile inflammatory response via common pathways. Here we review established and emerging data about these responses. PMID:20307211

  19. Sterilization, storage stability and in vivo biocompatibility of poly(trimethylene carbonate)/poly(adipic anhydride) blends.

    PubMed

    Edlund, U; Albertsson, A C; Singh, S K; Fogelberg, I; Lundgren, B O

    2000-05-01

    Biodegradable blends of poly(trimethylene carbonate) (PTMC) and poly(adipic anhydride) (PAA) have been proven to be strong candidates for controlled drug delivery polymers in vitro. We now report on the stability, sterilizability and in vivo local tissue response of these matrices. Blend matrices were sterilized by beta-radiation or ethylene oxide gas treatment, stored at different times and temperatures, and analyzed for changes in physicochemical properties. Moisture uptake at different relative humidities and storage times was determined. Sterilization procedures induced hydrolysis of the matrices. Ethylene oxide gas sterilization had a significantly more marked effect upon the matrix properties than radiation treatment. The onset of degradation was reflected in a decrease of crystallinity and molecular weight along with a change of blend composition. A similar onset of matrix degradation was observed upon storage in air. The physicochemical properties of the blends were well preserved upon storage under argon atmosphere. Biocompatibility of PTMC/PAA implants was assessed in the anterior chamber of rabbits eyes for 1 month. At selected post-operative time points, aqueous humor was analyzed for white blood cells and the corneal thickness was measured. The results suggest good biocompatability of PTMC-rich matrices, whereas fast eroding PAA-rich matrices caused inflammatory responses, due to a burst release of degradation products.

  20. Modeling the suppression of sea lamprey populations by the release of sterile males or sterile females

    USGS Publications Warehouse

    Klassen, Waldemar; Adams, Jean V.; Twohey, Michael B.

    2004-01-01

    The suppressive effects of trapping adult sea lampreys, Petromyzon marinus Linnaeus, and releasing sterile males (SMRT) or females (SFRT) into a closed system were expressed in deterministic models. Suppression was modeled as a function of the proportion of the population removed by trapping, the number of sterile animals released, the reproductive rate and sex ratio of the population, and (for the SFRT) the rate of polygyny. Releasing sterile males reduced populations more quickly than did the release of sterile females. For a population in which 30% are trapped, sterile animals are initially released at ratio of 10 sterile to 1 fertile animal, 5 adult progeny are produced per fertile mating, 60% are male, and males mate with an average of 1.65 females, the initial population is reduced 87% by SMRT and 68% by SFRT in one generation. The extent of suppression achieved is most sensitive to changes in the initial sterile release ratio. Given the current status of sea lamprey populations and trapping operations in the Great Lakes, the sterile-male-release technique has the best chance for success on a lake-wide basis if implemented in Lake Michigan. The effectiveness of the sterile-female-release technique should be investigated in a controlled study. Advancing trapping technology should be a high priority in the near term, and artificial rearing of sea lampreys to the adult stage should be a high priority in the long term. The diligent pursuit of sea lamprey suppression over a period of several decades can be expected to yield great benefits.

  1. Sterilization Efficiency of Spore forming Bacteria in Powdery Food by Atmospheric Pressure Plasmas Sterilizer

    NASA Astrophysics Data System (ADS)

    Nagata, Masayoshi; Tanaka, Masashi; Kikuchi, Yusuke

    2015-09-01

    To provide food sterilization method capable of killing highly heat resistant spore forming bacteria, we have studied effects of plasma treatment method at atmospheric pressure in order to develop a new high speed plasma sterilization apparatus with a low cost and a high efficiency. It is also difficult even for the plasma treatment to sterilize powdery food including spices such as soybean, basil and turmeric. This paper describes that an introduction of mechanical rotation of a treatment space increases the efficiency so that perfect inactivation of spore forming bacteria in these materials by a short treatment time has been demonstrated in our experiments. We also will discuss the sterilization mechanism by dielectric barrier discharge.

  2. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice.

    PubMed

    El-Namaky, R; van Oort, P A J

    2017-12-01

    There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two EGMS lines tested here, it was not clear if one or more recessive gene(s) were causing male sterility. This was tested by studying sterility segregation of the F2 populations. Daylength (photoperiod) and minimum temperatures during the period from panicle initiation to flowering had significant effects on male sterility. Results clearly showed that only one recessive gene was involved in causing male sterility. The model was applied to determine the set of sowing dates of two different EGMS lines such that both would flower at the same time the pollen would be completely sterile. In the same time the local popular variety (Sahel 108, the male pollen donor) being sufficiently fertile to produce the hybrid seeds. The model was applied to investigate the viability of the two line breeding system in the same location with climate change (+2oC) and in two other potential locations: in M'Be in Ivory Coast and in the Nile delta in Egypt. Apart from giving new insights in the relation between environment and EGMS, this study shows that these insights can be used to assess safe sowing windows and assess the suitability of sterility and fertility period of different environments for a two line hybrid rice production system.

  3. Study of the desorption of ethylene oxide fixed on various materials during sterilization by a new procedure

    NASA Technical Reports Server (NTRS)

    Lacomme, M.; Chaigneau, M.; Lemoan, G.

    1977-01-01

    A continuous sterilization process using ethylene oxide was studied in comparison with a classical method in order to evaluate gas retention as a function of time and temperature on polyethylene, PVC, and rubber materials.

  4. EOS imaging versus current radiography: A health technology assessment study

    PubMed Central

    Mahboub-Ahari, Alireza; Hajebrahimi, Sakineh; Yusefi, Mahmoud; Velayati, Ashraf

    2016-01-01

    Background: EOS is a 2D/3D muscle skeletal diagnostic imaging system. The device has been developed to produce a high quality 2D, full body radiographs in standing, sitting and squatting positions. Three dimensional images can be reconstructed via sterEOS software. This Health Technology Assessment study aimed to investigate efficacy, effectiveness and cost-effectiveness of new emerged EOS imaging system in comparison with conventional x-ray radiographic techniques. Methods: All cost and outcome data were assessed from Iran's Ministry of Health Perspective. Data for clinical effectiveness was extracted using a rigorous systematic review. As clinical outcomes the rate of x-ray emission and related quality of life were compared with Computed Radiography (CR) and Digital Radiography (DR). Standard costing method was conducted to find related direct medical costs. In order to examine robustness of the calculated Incremental Cost Effectiveness Ratios (ICERs) we used two-way sensitivity analysis. GDP Per capita of Islamic Republic of Iran (2012) adopted as cost-effectiveness threshold. Results: Review of related literature highlighted the lack of rigorous evidence for clinical outcomes. Ultra low dose EOS imaging device is known as a safe intervention because of FDA, CE and CSA certificates. The rate of emitted X-ray was 2 to 18 fold lower for EOS compared to the conventional techniques (p<0.001). The Incremental Cost Effectiveness Ratio for EOS relative to CR calculated $50706 in baseline analysis (the first scenario) and $50714, $9446 respectively for the second and third scenarios. Considering the value of neither $42146 as upper limit, nor the first neither the second scenario could pass the cost-effectiveness threshold for Iran. Conclusion: EOS imaging technique might not be considered as a cost-effective intervention in routine practice of health system, especially within in-patient wards. Scenario analysis shows that, only in an optimum condition such as lower

  5. Seeking sterile neutrinos in Finslerian cosmology

    NASA Astrophysics Data System (ADS)

    Wang, Deng; Meng, Xin-He

    2017-11-01

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H_0 tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N_eff=3.237^{+0.092}_{-0.185}, which is consistent with Δ N_eff > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N_eff=3.143^{+0.064}_{-0.066}, which favors Δ N_eff > 0 at the 1.47σ CL, and m_{ν , sterile}^eff < 0.121 eV at the 2σ CL which is much tighter than the Planck results. This very tight restriction appears to indicate the massive sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration.

  6. Thermalizing Sterile Neutrino Dark Matter

    NASA Astrophysics Data System (ADS)

    Hansen, Rasmus S. L.; Vogl, Stefan

    2017-12-01

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  7. Thermalizing Sterile Neutrino Dark Matter.

    PubMed

    Hansen, Rasmus S L; Vogl, Stefan

    2017-12-22

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  8. 21 CFR 522.44 - Sterile sodium acetazolamide.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Sterile sodium acetazolamide. 522.44 Section 522....44 Sterile sodium acetazolamide. (a) Specifications. Sterile sodium acetazolamide contains acetazolamide sodium complying with United States Pharmacopeia as a sterile powder with directions for...

  9. 21 CFR 522.44 - Sterile sodium acetazolamide.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Sterile sodium acetazolamide. 522.44 Section 522....44 Sterile sodium acetazolamide. (a) Specifications. Sterile sodium acetazolamide contains acetazolamide sodium complying with United States Pharmacopeia as a sterile powder with directions for...

  10. 21 CFR 522.44 - Sterile sodium acetazolamide.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile sodium acetazolamide. 522.44 Section 522....44 Sterile sodium acetazolamide. (a) Specifications. Sterile sodium acetazolamide contains acetazolamide sodium complying with United States Pharmacopeia as a sterile powder with directions for...

  11. 21 CFR 522.44 - Sterile sodium acetazolamide.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Sterile sodium acetazolamide. 522.44 Section 522....44 Sterile sodium acetazolamide. (a) Specifications. Sterile sodium acetazolamide contains acetazolamide sodium complying with United States Pharmacopeia as a sterile powder with directions for...

  12. EOS Terra: Mission Status Constellation MOWG

    NASA Technical Reports Server (NTRS)

    Mantziaras, Dimitrios

    2016-01-01

    This EOS Terra Mission Status Constellation MOWG will discuss mission summary; spacecraft subsystems summary, recent and planned activities; inclination adjust maneuvers, conjunction history, propellant usage and lifetime estimate; and end of mission plan.

  13. Lateral Diffusion in a DMPC:DMPE-EO Binary Monolayer at the Air/Water Interface

    NASA Astrophysics Data System (ADS)

    Adalsteinsson, Thorsteinn; Porter, Ryan; Yu, Hyuk

    2002-03-01

    Polyethylene glycol tethered phospholipids (lipo-polymers) have recently attracted attention for improving the stability of liposomes and other bilayer delivery systems. Here, we report a study of surface pressure measurement and diffusion measurements of a probe lipid (NBD-DMPC) in a binary monolayer of DMPC and DMPE-EO at the Air/Water interface. Our findings are that the DMPE-EO lipo-polymer desorbs from the interface at intermediate surface pressures if the EO tail is sufficiently large (i.e. EO_45) and does not interfere with the diffusion of the probe thereafter. In the case where the EO tail is short (i.e. EO_17) the lipo-polymer retards the diffusion of the probe, but as the surface pressure increases, the diffusion behavior approaches that of pure DMPC monolayer independent of lipo-polymer. Thus, we conclude that the surface pressure and EO molar mass dependent desorption of the lipo-polymer modulates the probe diffusion retardation.

  14. Follow That Satellite: EO-1 Maneuvers Into Close Formation With Landsat-7

    NASA Technical Reports Server (NTRS)

    DeFazio, Robert L.; Owens, Skip; Good, Susan; Bauer, Frank H. (Technical Monitor)

    2001-01-01

    As the Landsat-7 (LS-7) spacecraft continued NASA's historic program of earth imaging begun over three decades ago, NASA launched the Earth Observing-1 (EO-1) spacecraft carrying examples of the next generation of LS instruments. The validation method for these instruments was to have EO-1 fly in a close formation behind LS-7 on the same World Reference System (WRS) path. From that formation hundreds of near-coincident images would be taken by each spacecraft and compared to evaluate improvements in the EO-1 instruments. This paper will address the mission analysis required to launch and maneuver EO-1 into the formation with LS-7 where instrument validation was to occur plus a summary of completing the formation acquisition. Each EO-1 launch opportunity that occurred on a different day of a LS-7 16-day repeat cycle required a separate and distinct maneuver profile.

  15. Report of the EOS oceans panel to the payload panel

    NASA Astrophysics Data System (ADS)

    Abbott, Mark R.; Freilich, Michael H.

    1992-11-01

    The atmosphere and the ocean are the two great fluids of the earth system. Changes in the coupling of these two fluids will have a profound impact on the Earth's climate and biogeochemical systems. Although changes in atmospheric composition and dynamics are the usual focus of global climate models, it is apparent that the ocean plays a critical role in modulating the magnitude and rate of these changes. The ocean is responsible for nearly half of the poleward heat flux as well as for a significant portion of the uptake of atmospheric carbon dioxide. However, the processes governing the flux of materials and energy between the ocean atmosphere are poorly understood. Such processes include not only physical and chemical dynamics, but also biological processes which act to modify the chemical composition of the ocean as well as the trapping of solar energy as heat in the upper water column. Thus it is essential that the ocean be studied as a complete system of physical, chemical, and biological processes. Overlapping measurements must be made for at least 10-15 years to resolve critical low frequency fluctuations. The present EOS plan relies heavily on non-EOS entities to provide critical data sets for ocean studies. Although such partnerships are usually beneficial, there are risks that must be considered in terms of data coverage, quality, resolution, and availability. A simple replacement of an EOS sensor with a non-EOS sensor based on the fact that they both measure the same quantities will not guarantee that critical measurements will be made to address IPCC priorities in the area of ocean processes. EOS must continue to pursue appropriate methods to ensure that such partner — provided measurements meet scientific requirements. Such methods are analogous to contigencies applied in the area of schedules, cost, and performance for instrument projects. EOS must foster strong ties between US scientists and their foreign counterparts, in order to develop

  16. Implementing AORN recommended practices for sterile technique.

    PubMed

    Kennedy, Lynne

    2013-07-01

    Using sterile technique helps prevent the surgical environment from becoming contaminated and thus can help reduce the incidence of surgical site infection. The AORN "Recommended practices for sterile technique" provides guidance for setting up, maintaining, and monitoring a sterile field. Topics include the use of surgical attire and personal protective equipment; appropriate selection and evaluation of surgical gowns, gloves, and drape products for each procedure; use of sterile technique to don sterile gowns and gloves; appropriate methods for establishing and monitoring a sterile field; and techniques to ensure that items such as surgical instruments that may be contaminated are not used. Breaks in sterile technique should be corrected immediately unless the actions necessary would endanger the patient. If remedial actions must be delayed, they should be undertaken as soon as possible. Adhering to best practices for sterile technique requires remaining up to date with new approaches and incorporating these into quality initiatives. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  17. Earthquakes and depleted gas reservoirs: which comes first?

    NASA Astrophysics Data System (ADS)

    Mucciarelli, M.; Donda, F.; Valensise, G.

    2014-12-01

    While scientists are paying increasing attention to the seismicity potentially induced by hydrocarbon exploitation, little is known about the reverse problem, i.e. the impact of active faulting and earthquakes on hydrocarbon reservoirs. The recent 2012 earthquakes in Emilia, Italy, raised concerns among the public for being possibly human-induced, but also shed light on the possible use of gas wells as a marker of the seismogenic potential of an active fold-and-thrust belt. Based on the analysis of over 400 borehole datasets from wells drilled along the Ferrara-Romagna Arc, a large oil and gas reserve in the southeastern Po Plain, we found that the 2012 earthquakes occurred within a cluster of sterile wells surrounded by productive ones. Since the geology of the productive and sterile areas is quite similar, we suggest that past earthquakes caused the loss of all natural gas from the potential reservoirs lying above their causative faults. Our findings have two important practical implications: (1) they may allow major seismogenic zones to be identified in areas of sparse seismicity, and (2) suggest that gas should be stored in exploited reservoirs rather than in sterile hydrocarbon traps or aquifers as this is likely to reduce the hazard of triggering significant earthquakes.

  18. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Guaifenesin sterile powder. 522.1085 Section 522....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin. (b... drug in sterile water for injection to make a solution containing 50 milligrams of guaifenesin per...

  19. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Guaifenesin sterile powder. 522.1085 Section 522....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin. (b... drug in sterile water for injection to make a solution containing 50 milligrams of guaifenesin per...

  20. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Guaifenesin sterile powder. 522.1085 Section 522....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin. (b... drug in sterile water for injection to make a solution containing 50 milligrams of guaifenesin per...

  1. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Guaifenesin sterile powder. 522.1085 Section 522....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin. (b... drug in sterile water for injection to make a solution containing 50 milligrams of guaifenesin per...

  2. 21 CFR 522.1862 - Sterile pralidoxime chloride.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile pralidoxime chloride. 522.1862 Section 522....1862 Sterile pralidoxime chloride. (a) Chemical name. 2-Formyl-1-methylpyridinium chloride oxime. (b) Specifications. Sterile pralidoxime chloride is packaged in vials. Each vial contains 1 gram of sterile...

  3. Today's sterilizer is not your father's water heater.

    PubMed

    Moore, Thomas K

    2009-07-01

    Today's sterilizers are sophisticated, automatic, and computerized devices that accurately execute programmed jobs, creating uniform conditions inside pressure vessels to achieve sterilization. Specialized knowledge is necessary to ensure that the right cycle is selected; this requires an educated and competent operator.Perioperative nurses need to understand regulatory requirements for sterilizers, sterilizer design and performance validation, sterilizer cycle functions for everyday use, and everyday sterilization procedures.

  4. Calculation of Hugoniot properties for shocked nitromethane based on the improved Tsien's EOS

    NASA Astrophysics Data System (ADS)

    Zhao, Bo; Cui, Ji-Ping; Fan, Jing

    2010-06-01

    We have calculated the Hugoniot properties of shocked nitromethane based on the improved Tsien’s equation of state (EOS) that optimized by “exact” numerical molecular dynamic data at high temperatures and pressures. Comparison of the calculated results of the improved Tsien’s EOS with the existed experimental data and the direct simulations show that the behavior of the improved Tsien’s EOS is very good in many aspects. Because of its simple analytical form, the improved Tsien’s EOS can be prospectively used to study the condensed explosive detonation coupling with chemical reaction.

  5. Plasma Sterilization: New Epoch in Medical Textiles

    NASA Astrophysics Data System (ADS)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  6. Light sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Gariazzo, S.; Giunti, C.; Laveder, M.; Li, Y. F.; Zavanin, E. M.

    2016-03-01

    The theory and phenomenology of light sterile neutrinos at the eV mass scale is reviewed. The reactor, gallium and Liquid Scintillator Neutrino Detector anomalies are briefly described and interpreted as indications of the existence of short-baseline oscillations which require the existence of light sterile neutrinos. The global fits of short-baseline oscillation data in 3 + 1 and 3 + 2 schemes are discussed, together with the implications for β-decay and neutrinoless double-β decay. The cosmological effects of light sterile neutrinos are briefly reviewed and the implications of existing cosmological data are discussed. The review concludes with a summary of future perspectives. This review is dedicated to the memory of Hai-Wei Long, our dear friend and collaborator, who passed away on 29 May 2015. He was an exceptionally kind person and an enthusiastic physicist. We deeply miss him.

  7. EOS 2D/3D X-ray imaging system: a systematic review and economic evaluation.

    PubMed

    McKenna, C; Wade, R; Faria, R; Yang, H; Stirk, L; Gummerson, N; Sculpher, M; Woolacott, N

    2012-01-01

    EOS is a biplane X-ray imaging system manufactured by EOS Imaging (formerly Biospace Med, Paris, France). It uses slot-scanning technology to produce a high-quality image with less irradiation than standard imaging techniques. To determine the clinical effectiveness and cost-effectiveness of EOS two-dimensional (2D)/three-dimensional (3D) X-ray imaging system for the evaluation and monitoring of scoliosis and other relevant orthopaedic conditions. For the systematic review of EOS, electronic databases (MEDLINE, Allied and Complementary Medicine Database, BIOSIS Previews, Cumulative Index to Nursing and Allied Health Literature, The Cochrane Library, EMBASE, Health Management Information Consortium, Inspec, ISI Science Citation Index and PASCAL), clinical trials registries and the manufacturer's website were searched from 1993 to November 2010. A systematic review of studies comparing EOS with standard X-ray [film, computed radiography (CR) or digital radiography] in any orthopaedic condition was performed. A narrative synthesis was undertaken. A decision-analytic model was developed to assess the cost-effectiveness of EOS in the relevant indications compared with standard X-ray and incorporated the clinical effectiveness of EOS and the adverse effects of radiation. The model incorporated a lifetime horizon to estimate outcomes in terms of quality-adjusted life-years (QALYs) and costs from the perspective of the NHS. Three studies met the inclusion criteria for the review. Two studies compared EOS with film X-ray and one study compared EOS with CR. The three included studies were small and of limited quality. One study used an earlier version of the technology, the Charpak system. Both studies comparing EOS with film X-ray found image quality to be comparable or better with EOS overall. Radiation dose was considerably lower with EOS: ratio of means for posteroanterior spine was 5.2 (13.1 for the study using the Charpak system); ratio of means for the lateral spine

  8. An European framework for the long term preservation of EO data

    NASA Astrophysics Data System (ADS)

    Forcada, E.; Albani, M.; Beruti, V.

    2009-04-01

    The need for accessing historical Earth Observation (EO) data series strongly increased in the last ten years, mainly for long term science and environmental monitoring applications. This trend is likely to increase even more in the future in particular for the growing interest on global change monitoring that requires data time-series spanning 20 years and more, and for the need to support the United Nations Framework Convention on Climate Change (UNFCCC). Content of EO data archives is extending from a few years to decades and their scientific value is continuously increasing hence is well recognized the need to preserve them without time limitation and to keep the archived EO data well accessible and exploitable as they constitute a humankind asset. The large amount of new Earth Observation missions upcoming in the next years will moreover lead to a major increase of EO data volumes. This fact, together with the increased demands from the scientific user community, marks a challenge for Earth Observation satellite operators, Space Agencies and EO data providers regarding coherent data preservation and optimum availability and accessibility of the different data products. Traditionally in Europe, there has been poor cooperation in this field with no common approach for long term preservation and access to EO space data even if cooperation and sharing are key aspects to be pursued for the benefit of the user community. Single organizations have difficulties to afford data preservation in the long term that calls for the need of optimising costs and efforts, identifying commonalities. In 2006, the European Space Agency (ESA) initiated a coordination action to share among all the European (and Canadian) stakeholders a common approach to the long term preservation of Earth Observation data. During 2007, the Agency started consultations with its Member States presenting an EO Long Term Data Preservation (LTDP) strategy targeting the preservation of all European

  9. Orbit determination and orbit control for the Earth Observing System (EOS) AM spacecraft

    NASA Technical Reports Server (NTRS)

    Herberg, Joseph R.; Folta, David C.

    1993-01-01

    Future NASA Earth Observing System (EOS) Spacecraft will make measurements of the earth's clouds, oceans, atmosphere, land and radiation balance. These EOS Spacecraft will be part of the NASA Mission to Planet Earth. This paper specifically addresses the EOS AM Spacecraft, referred to as 'AM' because it has a sun-synchronous orbit with a 10:30 AM descending node. This paper describes the EOS AM Spacecraft mission orbit requirements, orbit determination, orbit control, and navigation system impact on earth based pointing. The EOS AM Spacecraft will be the first spacecraft to use the TDRSS Onboard Navigation System (TONS) as the primary means of navigation. TONS flight software will process one-way forward Doppler measurements taken during scheduled TDRSS contacts. An extended Kalman filter will estimate spacecraft position, velocity, drag coefficient correction, and ultrastable master oscillator frequency bias and drift. The TONS baseline algorithms, software, and hardware implementation are described in this paper. TONS integration into the EOS AM Spacecraft Guidance, Navigation, and Control (GN&C) System; TONS assisted onboard time maintenance; and the TONS Ground Support System (TGSS) are also addressed.

  10. Study on the role of active radicals on plasma sterilization inside small diameter flexible polymeric tubes

    NASA Astrophysics Data System (ADS)

    Mstsuura, Hiroto; Fujiyama, Takatomo; Okuno, Yasuki; Furuta, Masakazu; Okuda, Shuichi; Takemura, Yuichiro

    2015-09-01

    Recently, atmospheric pressure discharge plasma has gathered attention in various fields. Among them, plasma sterilization with many types of plasma source has studied for decades and its mechanism is still an open question. If active radicals produced in plasma has main contribution of killing bacterias, direct contact of the so-called plasma flame might not be necessary. To confirm this, sterilization inside small diameter flexible polymeric tubes is studied in present work. DBD type plasma jet is produce by flowing helium gas in a glass tube. A long polymeric tube is connected and plasma jet is introduced into it. Plasma flame length depends on helium gas flow rate, but limited to about 10 cm in our experimental condition. E.colis set at the exit plasma source is easily killed during 10 min irradiation. At the tube end (about 20 cm away from plasma source exit), sterilization is possible with 30 min operation. This result shows that active radical is produced with helium plasma and mist contained in sample, and it can be transferred more than 20 cm during it life time. More plasma diagnostic data will also be shown at the conference. This work was partially supported by the ''ZE Research Program, IAE(ZE27B-4).

  11. Terrestrial remote sensing science and algorithms planned for EOS/MODIS

    USGS Publications Warehouse

    Running, S. W.; Justice, C.O.; Salomonson, V.V.; Hall, D.; Barker, J.; Kaufmann, Y. J.; Strahler, Alan H.; Huete, A.R.; Muller, Jan-Peter; Vanderbilt, V.; Wan, Z.; Teillet, P.; Carneggie, David M. Geological Survey (U.S.) Ohlen

    1994-01-01

    The Moderate Resolution Imaging Spectroradiometer (MODIS) will be the primary daily global monitoring sensor on the NASA Earth Observing System (EOS) satellites, scheduled for launch on the EOS-AM platform in June 1998 and the EOS-PM platform in December 2000. MODIS is a 36 channel radiometer covering 0·415-14·235 μm wavelengths, with spatial resolution from 250 m to 1 km at nadir. MODIS will be the primary EOS sensor for providing data on terrestrial biospheric dynamics and process activity. This paper presents the suite of global land products currently planned for EOSDIS implementation, to be developed by the authors of this paper, the MODIS land team (MODLAND). These include spectral albedo, land cover, spectral vegetation indices, snow and ice cover, surface temperature and fire, and a number of biophysical variables that will allow computation of global carbon cycles, hydrologic balances and biogeochemistry of critical greenhouse gases. Additionally, the regular global coverage of these variables will allow accurate surface change detection, a fundamental determinant of global change.

  12. Enhanced modeling and simulation of EO/IR sensor systems

    NASA Astrophysics Data System (ADS)

    Hixson, Jonathan G.; Miller, Brian; May, Christopher

    2015-05-01

    The testing and evaluation process developed by the Night Vision and Electronic Sensors Directorate (NVESD) Modeling and Simulation Division (MSD) provides end to end systems evaluation, testing, and training of EO/IR sensors. By combining NV-LabCap, the Night Vision Integrated Performance Model (NV-IPM), One Semi-Automated Forces (OneSAF) input sensor file generation, and the Night Vision Image Generator (NVIG) capabilities, NVESD provides confidence to the M&S community that EO/IR sensor developmental and operational testing and evaluation are accurately represented throughout the lifecycle of an EO/IR system. This new process allows for both theoretical and actual sensor testing. A sensor can be theoretically designed in NV-IPM, modeled in NV-IPM, and then seamlessly input into the wargames for operational analysis. After theoretical design, prototype sensors can be measured by using NV-LabCap, then modeled in NV-IPM and input into wargames for further evaluation. The measurement process to high fidelity modeling and simulation can then be repeated again and again throughout the entire life cycle of an EO/IR sensor as needed, to include LRIP, full rate production, and even after Depot Level Maintenance. This is a prototypical example of how an engineering level model and higher level simulations can share models to mutual benefit.

  13. [Legal statutes on sterilization].

    PubMed

    Zupancic, K

    1980-01-01

    Sterilization in Yugoslavia is no population policy measure. Decision about the birth of children is free, a private problem of any individual, a basic right guaranteed by the Constitution. However, according to certain laws in Slovenia and Croatia, sterilization is allowed as a family planning method in persons over 35 year old. Only exceptionally can sterilization be applied in persons younger than 35 years: according to the Slovenian law, in cases when a person lacks the capacity of reasoning and also when there are medical indications, and according to the Croatian law, when there are medical and eugenic reasons (if the child is supposed to be born with negative congenital properties).

  14. Do CAS measurements correlate with EOS 3D alignment measurements in primary TKA?

    PubMed

    Meijer, Marrigje F; Boerboom, Alexander L; Bulstra, Sjoerd K; Reininga, Inge H F; Stevens, Martin

    2017-09-01

    Objective of this study was to compare intraoperative computer-assisted surgery (CAS) alignment measurements during total knee arthroplasty (TKA) with pre- and postoperative coronal alignment measurements using EOS 3D reconstructions. In a prospective study, 56 TKAs using imageless CAS were performed and coronal alignment measurements were recorded twice: before bone cuts were made and after implantation of the prosthesis. Pre- and postoperative coronal alignment measurements were performed using EOS 3D reconstructions. Thanks to the EOS radiostereography system, measurement errors due to malpositioning and deformity during acquisition are eliminated. CAS measurements were compared with EOS 3D reconstructions. Varus/valgus angle (VV), mechanical lateral distal femoral angle (mLDFA) and mechanical medial proximal tibial angle (mMPTA) were measured. Significantly different VV angles were measured pre- and postoperatively with CAS compared to EOS. For preoperative measurements, mLDFA did not differ significantly, but a significantly larger mMPTA in valgus was measured with CAS. Results of this study indicate that differences in alignment measurements between CAS measurements and pre- and postoperative EOS 3D are due mainly to the difference between weight-bearing and non-weight-bearing position and potential errors in validity and reliability of the CAS system. EOS 3D measurements overestimate VV angle in lower limbs with substantial mechanical axis deviation. For lower limbs with minor mechanical axis deviation as well as for mMPTA measurements, CAS measures more valgus than EOS. Eventually the results of this study are of clinical relevance, since it raises concerns regarding the validity and reliability of CAS systems in TKA. IIb.

  15. Effects of a protease and essential oils on growth performance, blood cell profiles, nutrient retention, ileal microbiota, excreta gas emission, and breast meat quality in broiler chicks.

    PubMed

    Park, J H; Kim, I H

    2018-05-19

    A total of 360 Ross male broiler chicks (39.8 ± 1.8 g) were used in a five week experiment to determine the effect of a protease and essential oils (EO) on growth performance, blood cell profile, nutrient retention, ileal microbiota, excreta gas emission, and breast meat quality in broiler chicks. Broiler chicks were randomly allotted to four dietary treatments with 15 birds/cage and six cages/treatment. Experimental treatments were arranged as a 2 × 2 factorial with two levels of protease (0 and 0.02%) and two levels of EO (0 and 0.03%). For days 8 to 21 and overall, body weight gain and the feed conversion ratio were better in broilers fed diets supplemented with protease (P < 0.05) than in those fed diets without protease supplementation. Protease and/or EO increased (P < 0.05) the total tract retention of dry matter, nitrogen, or gross energy, and decreased the excreta ammonia gas emission. In addition, there was a significant interaction between the protease and EO on total tract retention of nitrogen and excreta ammonia gas emission (P < 0.05). The density of ileal Lactobacillus increased and Escherichia coli decreased in broilers (P < 0.05) by the addition of EO to the diet. There were no significant differences in the measurements of breast meat quality and organ weight of broilers fed diets with protease or EO. In conclusion, diets with a combination of a protease and EO improved total tract retention of nitrogen and excreta ammonia gas emission in growing broiler chicks.

  16. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  17. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  18. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  19. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  20. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat. (b...

  1. Stoichiometric Lithium Niobate (SLN) Based Linearized Electro-Optic (EO) Modulator

    DTIC Science & Technology

    2006-01-01

    AFRL-SN-RS-TR-2006-15 Final Technical Report January 2006 STOICHIOMETRIC LITHIUM NIOBATE (SLN) BASED LINEARIZED ELECTRO - OPTIC (EO...LITHIUM NIOBATE (SLN) BASED LINEARIZED ELECTRO - OPTIC (EO) MODULATOR 6. AUTHOR(S) Dr Stuart Kingsley, Dr Sri Sriram 5. FUNDING NUMBERS C...SUBJECT TERMS electro - optic modulator, linearization, directional coupler, variable coupling, optical waveguide, Mach-Zehnder, photonic link, lithium

  2. Signature of heavy sterile neutrinos at CEPC

    NASA Astrophysics Data System (ADS)

    Liao, Wei; Wu, Xiao-Hong

    2018-03-01

    We study the production of heavy sterile neutrino N , e+e-→N ν (ν ¯), at the Circular Electron Positron Collider (CEPC) and its l j j signal in its decay to three charged fermions. We study background events for this process which are mainly events coming from W pair production. We study the production of a single heavy sterile neutrino and the sensitivity of CEPC to the mixing of the sterile neutrino with active neutrinos. We study the production of two degenerate heavy sterile neutrinos in a low energy seesaw model by taking into account the constraints on mixings of sterile neutrinos from the neutrinoless double β decay experiment and the masses and mixings of active neutrinos. We show that CEPC under proposal has a good sensitivity to the mixing of sterile neutrinos with active neutrinos for a mass of a sterile neutrino around 100 GeV.

  3. Continuous sterilization of plumbing systems

    NASA Technical Reports Server (NTRS)

    Bryan, C. J.; Moyers, C. V.; Wright, E. E., Jr.

    1979-01-01

    Continuous sterilization of plumbing, such as in hospitals, clinics, and biological testing laboratories is possible with ethylene oxide/Freon 12 (ETO/F-12) humidifier developed for sterilization of potable water systems.

  4. Outpatient laparoscopic sterilization.

    PubMed

    Hamid Arshat; Yuliawiratman

    1981-03-01

    This is a report on a pilot study conducted in Malaysia of outpatient sterilization utilizing laparoscopic technique under local anesthesia and sedation. The preliminary report based on 305 patients is presented with emphasis on the advantages and possible weaknesses of such procedure. Sterilization is performed in the Family Planning Specialist Center, Maternity Hospital. Patients are motivated towards sterilization during the immediate postpartum period in the Maternity Hospital and are counseled regarding the actual procedure. The mean age of the 305 patients was 32.08 years; the mean gravidity was 4.92; and the mean parity was 4.57. The majority of the patients came from the lower social strata with low educational attainment and low income. 253 cases of sterilizations were performed by laparoscopic procedures and 43 cases by minilaparotomy. In 9 cases difficulty was encountered with laparoscopy and subsequently the minilaparotomy was used. The majority of cases seemed to tolerate the sedation and local anesthesia fairly well and without much complaint of pain. Only a very small number of patients complained of pain particularly at the time when the Fallope or Lay rings were applied to the fallopian tubes. The overall complication rate was 14 (4.9%) and of these mild wound sepsis accounted for 6 (1.96%). Most of the wound sepsis was very mild and healed very quickly on daily dressing. No cases of pelvic sepsis were reported. There were 3 cases of uterine perforation by the uterine elevator. There were 2 cases where the fallopian tubes were traumatized and some degree of bleeding occurred. The bleeding was easily controlled by applying another Fallope ring. 2 patients had vomiting during the laparoscopic procedure. There were 7 cases of failed sterilization. 6 of the cases were performed by a trainee registrar in obstetrics and gynecology. The last was performed by a specialist gynecologist. Most of the failures were due to wrong application of rings. The cost

  5. The sterility of hospital-prepared Soffban bandages.

    PubMed

    Wood, E V; Fenwick, H; Manning, M P; Mobbs, P

    2005-11-01

    An evaluation of the sterility of hospital-prepared Soffban bandages was undertaken. Discs of Bacillus stearothermophilus were inserted into the bandage rolls, prior to sterilization in "porous load" autoclaves. The discs were subsequently removed and placed in culture media, with growth of the organism indicating failure of sterilization. It was demonstrated that Soffban could not be sterilized reliably using standard hospital autoclave techniques.

  6. Molecular Solid EOS based on Quasi-Harmonic Oscillator approximation for phonons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menikoff, Ralph

    2014-09-02

    A complete equation of state (EOS) for a molecular solid is derived utilizing a Helmholtz free energy. Assuming that the solid is nonconducting, phonon excitations dominate the specific heat. Phonons are approximated as independent quasi-harmonic oscillators with vibrational frequencies depending on the specific volume. The model is suitable for calibrating an EOS based on isothermal compression data and infrared/Raman spectroscopy data from high pressure measurements utilizing a diamond anvil cell. In contrast to a Mie-Gruneisen EOS developed for an atomic solid, the specific heat and Gruneisen coefficient depend on both density and temperature.

  7. Space-shuttle interfaces/utilization. Earth Observatory Satellite system definition study (EOS)

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The economic aspects of space shuttle application to a representative Earth Observatory Satellite (EOS) operational mission in the various candidate Shuttle modes of launch, retrieval, and resupply are discussed. System maintenance of the same mission capability using a conventional launch vehicle is also considered. The studies are based on application of sophisticated Monte Carlo mission simulation program developed originally for studies of in-space servicing of a military satellite system. The program has been modified to permit evaluation of space shuttle application to low altitude EOS missions in all three modes. The conclusions generated by the EOS system study are developed.

  8. Forced sterilization of women as discrimination.

    PubMed

    Patel, Priti

    2017-01-01

    There has been a long history of subjecting marginalized women to forced and coerced sterilization. In recent years, the practice has been documented in countries in North and South America, Europe, Asia, and Africa. It has targeted women who are ethnic and racial minorities, women with disabilities, women living with HIV, and poor women. A handful of courts have issued decisions on the recent forced sterilization of marginalized women finding that such actions violate the women's rights. However, they have all failed to address the women's claims of discrimination. The failure to acknowledge that forced sterilization is at its core a violation of the prohibition of discrimination undermines efforts to eradicate the practice. It further fails to recognize that coerced and forced sterilization fundamentally seeks to deny women deemed as "unworthy" the ability to procreate. Four key principles outlined in the human rights in patient care framework highlight the importance of a finding that the prohibition of discrimination was violated in cases of forced sterilization: the need to highlight the vulnerability of marginalized populations to discrimination in health care settings; the importance of the rights of medical providers; the role of the state in addressing systemic human rights violations in health care settings; and the application of human rights to patient care. Based on these principles, it is clear that finding a violation of the prohibition of discrimination in forced sterilization cases is critical in addressing the systemic nature of the practice, acknowledging the marginalization of specific groups and effectively ending forced sterilization through addressing the underlying purpose of the practice. If litigators, non-governmental organizations and judicial officers are mindful of these principles when dealing with cases of forced sterilization, it is likely that they will be better able to eradicate forced sterilization.

  9. Sterilization in the United States

    PubMed Central

    Bartz, Deborah; Greenberg, James A

    2008-01-01

    Unintended pregnancies are expensive for patients and for society in terms of medical costs, the cost of caring for more children, and the cost to personal and professional goals. Sterilization is the most common contraceptive method utilized by couples in the United States. Given technological advances over the past few decades, male and female surgical sterilization has become a safe, convenient, easy, and highly effective birth control method for the long term. This article reviews current male and female sterilization options. PMID:18701927

  10. SURVEY ON PREVACUUM HIGH-PRESSURE STEAM STERILIZERS.

    PubMed

    DARMADY, E M; DREWETT, S E; HUGHES, K E

    1964-03-01

    None of the 10 prevacuum high-pressure sterilizers of different makes tested was able to produce and maintain the conditions advocated by the Medical Research Council working party on high-pressure steam sterilizers (1959) or by Knox and Penikett (1958) with the result that steam did not penetrate adequately the single challenge load and it was not sterilized. The sterilization of ;group drums' of various sizes and contents was erratic and tended to give operators a false sense of security. An alarming number of minor engineering faults were present in seven out of 10 machines tested and they require very much more skilled maintenance than is being given at the moment. The possibility of centralizing sterilizers to central sterile supply departments and placing them under the care of a regional engineer cannot be too highly recommended. The presence of undetected ;leaks' and a failure to draw a prevacuum of 20 mm. even with a steam burst interferes with sterilization of a challenge load. A leak test should be performed twice daily and should not exceed more than 1 mm. in one minute at 20 mm. absolute. The centre of the load should be monitored by crossed tapes or Brownes tubes in each sterilizing cycle. Although the challenge load was sterilized when the chamber was filled to capacity, a more reliable cycle consisting of a double prevacuum of 20 mm. or more with intermediate steam burst to 10 lb. ensured the sterilizing of a single challenge load, which could be adequately controlled by the chamber drain temperature.

  11. Survey on prevacuum high-pressure steam sterilizers

    PubMed Central

    Darmady, E. M.; Drewett, S. E.; Hughes, K. E. A.

    1964-01-01

    None of the 10 prevacuum high-pressure sterilizers of different makes tested was able to produce and maintain the conditions advocated by the Medical Research Council working party on high-pressure steam sterilizers (1959) or by Knox and Penikett (1958) with the result that steam did not penetrate adequately the single challenge load and it was not sterilized. The sterilization of `group drums' of various sizes and contents was erratic and tended to give operators a false sense of security. An alarming number of minor engineering faults were present in seven out of 10 machines tested and they require very much more skilled maintenance than is being given at the moment. The possibility of centralizing sterilizers to central sterile supply departments and placing them under the care of a regional engineer cannot be too highly recommended. The presence of undetected `leaks' and a failure to draw a prevacuum of 20 mm. even with a steam burst interferes with sterilization of a challenge load. A leak test should be performed twice daily and should not exceed more than 1 mm. in one minute at 20 mm. absolute. The centre of the load should be monitored by crossed tapes or Brownes tubes in each sterilizing cycle. Although the challenge load was sterilized when the chamber was filled to capacity, a more reliable cycle consisting of a double prevacuum of 20 mm. or more with intermediate steam burst to 10 lb. ensured the sterilizing of a single challenge load, which could be adequately controlled by the chamber drain temperature. PMID:14149935

  12. NASA's Earth Observing System (EOS): Delivering on the Dream, Today and Tomorrow

    NASA Technical Reports Server (NTRS)

    Kelly, Angelita C.; Johnson, Patricia; Case, Warren F.

    2010-01-01

    This paper describes the successful operations of NASA's Earth Observing System (EOS) satellites over the past 10 years and the plans for the future. Excellent operations performance has been a key factor in the overall success of EOS. The EOS Program was conceived in the 1980s and began to take shape in the early 1990s. EOS consists of a series of satellites that study the Earth as an interrelated system. It began with the launch of Terra in December 1999, followed by Aqua in May 2002, and Aura in July 2004. A key EOS goal is to provide a long-term continuous data set to enable the science community to develop a better understanding of land, ocean, and atmospheric processes and their interactions. EOS has produced unprecedented amounts of data which are used all over the world free of charge. Mission operations have resulted in data recovery for Terra, Aqua, and Aura that have consistently exceeded mission requirements. The paper describes the ground systems and organizations that control the EOS satellites, capture the raw data, and distribute the processed science data sets. The paper further describes how operations have evolved since 1999. Examples of this evolution include (a) the implementation of new mission safety requirements for orbital debris monitoring; (b) technology upgrades to keep facilities at the state of the art; (c) enhancements to meet changing security requirements; and (d) operations management of the 2 international Earth Observing Constellations of 11 satellites known as the "Morning Constellation" and the "A-Train". The paper concludes with a view into the future based on the latest spacecraft status, lifetime projections, and mission plans.

  13. Patient-provider conversations about sterilization: A qualitative analysis.

    PubMed

    Kimport, Katrina; Dehlendorf, Christine; Borrero, Sonya

    2017-03-01

    Although female sterilization is the second most commonly used contraceptive method in the US, research suggests that providers may serve as barriers to desired sterilization. We conducted a modified grounded theory analysis of audio-recorded contraceptive counseling visits with 52 women who specified on a previsit survey that they wanted no future children and a supplemental analysis of visits with 14 women who wanted or were unsure about future children in which sterilization was mentioned. Sterilization was discussed in only 19 of the 52 visits, primarily with patients who were older women with children. Although some framed sterilization positively, many clinicians discouraged patients from pursuing sterilization, encouraging them instead to use long-acting reversible methods and framing the permanence of sterilization as undesirable. In the 33 remaining sessions, sterilization was not mentioned, and clinicians largely failed to solicit patients' future reproductive intentions. We found no clear patterns regarding discussion of sterilization in the 14 supplemental cases. Clinicians did not discuss sterilization with all patients for whom it might have been appropriate and thus missed opportunities to discuss sterilization as part of the full range of appropriate methods. When they did discuss sterilization, they only infrequently presented the method in positive ways and more commonly encouraged patients to choose a long-acting reversible method instead. Clinicians may want to reflect on their counseling practices around sterilization to ensure that counseling is centered on patient preferences, rather than driven by their own assumptions about the desirability of reversibility. Clinicians often fail to discuss sterilization as a contraceptive option with potentially appropriate candidates and, when they do, often discourage its selection. Clinicians should consider assessing reproductive intentions to ensure that potentially relevant methods are included in

  14. Sterilization: women fit to be tied.

    PubMed

    Caress, B

    1975-01-01

    Sterilization abuse is both systematic and widespread. Frequently, women are misled about the dangers of surgery, misinformed about its permanence, and coerced while under the stress of labor or abortion. Generally, instances of abuses in the health system are treated as illegitimate, illegal aberations of an otherwise decent health care system. Careful examination of these so called abuses would reveal that each can be causally connected to particular aspects of the care of America's health system. Sterilization abuse stems from a combination of factors inherent in the health system plus 1 critical additional factor. Besides resulting from teaching and research imperatives, profit making, and the fee for service systems, such abuse is the most widespread example of medicine as an instrument of social control. Sterilization is the most extreme form of birth control and birth control is official US government policy. There were about 500,000 sterilizations performed on American women in 1973. None of the sterilization methods is innocuous, and each is associated with some physical and psychological side effects. General agreement exists in the medical literature that some risk is attendant to each procedure. Sterilization is the most dangerous and the fastest growing method of birth control. Since 1970 the figures show an almost 3-fold increase in the incidence of female sterilization, from 192,000 in 1970 to 548,000 in 1974. Much evidence exists to suggest that the increase in the number of sterilizations has fueled a trend toward the sterilization of younger women with fewer children. Official accommodation to liberalization of sterilization practices in the US came in 1969, when the American College of Obstetricians and Gynecologists (ACOG) withdrew its age parity formula. This liberalization of sterilization guidelines opened the floodgates to abuse. Some of the increase in the number of operations performed is due to increased demand, some of it is the result

  15. Canadian Vehicle Protection Program (EO considerations)

    DTIC Science & Technology

    2012-10-09

    HFI); EO and Acoustic Sensing. – Situational Awareness Technologies Evaluation (SITUATE). – Urban Gated Laser Retro -reflection Scanner (UGLARES...llery Rockets Terminal Defeat of VSRBM 1 Destroy Soft Destroy Soft UAVs Destroy In-Flight Artillery Shells UAVs at at Long Range Short Range

  16. Sterile neutrino dark matter with supersymmetry

    NASA Astrophysics Data System (ADS)

    Shakya, Bibhushan; Wells, James D.

    2017-08-01

    Sterile neutrino dark matter, a popular alternative to the WIMP paradigm, has generally been studied in non-supersymmetric setups. If the underlying theory is supersymmetric, we find that several interesting and novel dark matter features can arise. In particular, in scenarios of freeze-in production of sterile neutrino dark matter, its superpartner, the sterile sneutrino, can play a crucial role in early Universe cosmology as the dominant source of cold, warm, or hot dark matter, or of a subdominant relativistic population of sterile neutrinos that can contribute to the effective number of relativistic degrees of freedom Neff during big bang nucleosynthesis.

  17. Ultraspectral Infrared Measurements from the Atmospheric Infrared Sounder (AIRS) on the EOS Aqua Spacecraft

    NASA Technical Reports Server (NTRS)

    Pagano, Thomas

    2003-01-01

    Aqua measures the Earth's water cycle, energy fluxes, vegetation and temperatures. The Atmospheric Infrared Sounder (AIRS), Advanced Microwave Sounding Unit (AMSU) and Humidity Sounder for Brazil (HSB) were launched on the EOS Aqua spacecraft in May 2002. AIRS has had good radiometric and spectral sensitivity, stability, and accuracy and is suitable for climate studies. Temperature products compare well with radiosondes and models over the limited test range (|LAT| less than 40 degrees). Early trace gas products demonstrate the potential of AIRS. NASA is developing the next generation of hyperspectral IR imagers. JPL is ready to participate with US government agencies and US industry to transfer AIRS technology and science experience.

  18. Evaluation of new technique of sterilization using biological indicator.

    PubMed

    Sheth, Nomal Chintan; Rathod, Yogesh V; Shenoi, Pratima R; Shori, Deepa D; Khode, Rajiv T; Khadse, Amruta P

    2017-01-01

    A novel technique of sterilization of endodontic files is introduced in this article. Newly introduced sterilization unit, named "SteriFast" is compared with autoclave and glass bead sterilizer using biological indicator. Spore strips of Bacillus pumilus were cultured in nutrient broth. This cultured media was used to contaminate the experimental samples of endodontic files. These contaminated files were sterilized using three different techniques. The sterilized files were transferred into nutrient medium under aseptic condition. The results were observed after 24 h, 48 h, and 7 days. The results showed that autoclave and new sterilization device (SteriFast) showed complete sterilization. The files sterilized using glass bead sterilizer showed bacterial growth (80%). Thus, it proves that autoclave and SteriFast are ideal techniques of sterilization of endodontic files. Glass bead sterilizer does not completely sterilize the files. The article also compares SteriFast and autoclave in other aspects such as its design, basic principle, advantages, and disadvantages. The article also describes features and design of SteriFast, used for all kind of small dental instruments.

  19. A European Collaborative EO Summer School for the Education of Undergraduate and Masters Level Students- FORMAT-EO

    NASA Astrophysics Data System (ADS)

    Graves, Rosemarie; Remedios, John; Tramutoli, Valerio; Gil, Artur; Cuca, Branka

    2014-05-01

    An Erasmus intensive programme has been successfully funded to run a Europe-lead summer school in Earth Observation for the years 2013 and 2014. The summer school, FORMAT-EO (FORmation of Multi-disciplinary Approaches to Training in Earth Observation) has been proposed and implemented by a consortium of eight partner institutions from five European countries. The consortium was facilitated through the NEREUS network. In the summer of 2013, 21 students from seven European institutions took part in the two week intensive course which involved a total of 28 teachers from six institutions. Students were from a variety of backgrounds including aeronautical engineering MSc students and PhD students in the areas of marine biology, earthquake engineering and measurement of trace gases in the atmosphere. The aims of FORMAT-EO were: To give students exposure to the wider applications of Earth Observation To highlight the interdisciplinary, collaborative and international nature of Earth Observation To offer an intensive course to better equip students with specialist skills required for a career in this field To provide expert advice on the development of careers in the EO market Partners were invited not only to recruit students for the course but to also teach at the school based on their specific area of expertise. This approach to the teaching provided a timetable which was wide-ranging and covered topics from EU policies for Earth Observation to fire detection from space and an introduction to interaction between radiation and matter. An important aspect of the course was the interactive nature of much of the teaching. A topic was introduced to the students through a lecture followed by an interactive tutorial providing students with hands-on experience of working with EO data and specialist software. The final days of the summer school were spent on group project work which required students to use all of the skills that they acquired during the course to challenge a

  20. Genetic complexity underlying hybrid male sterility in Drosophila.

    PubMed

    Sawamura, Kyoichi; Roote, John; Wu, Chung-I; Yamamoto, Masa-Toshi

    2004-02-01

    Recent genetic analyses of closely related species of Drosophila have indicated that hybrid male sterility is the consequence of highly complex synergistic effects among multiple genes, both conspecific and heterospecific. On the contrary, much evidence suggests the presence of major genes causing hybrid female sterility and inviability in the less-related species, D. melanogaster and D. simulans. Does this contrast reflect the genetic distance between species? Or, generally, is the genetic basis of hybrid male sterility more complex than that of hybrid female sterility and inviability? To clarify this point, the D. simulans introgression of the cytological region 34D-36A to the D. melanogaster genome, which causes recessive male sterility, was dissected by recombination, deficiency, and complementation mapping. The 450-kb region between two genes, Suppressor of Hairless and snail, exhibited a strong effect on the sterility. Males are (semi-)sterile if this region of the introgression is made homozygous or hemizygous. But no genes in the region singly cause the sterility; this region has at least two genes, which in combination result in male sterility. Further, the males are less fertile when heterozygous with a larger introgression, which suggests that dominant modifiers enhance the effects of recessive genes of male sterility. Such an epistatic view, even in the less-related species, suggests that the genetic complexity is special to hybrid male sterility.

  1. Genetic complexity underlying hybrid male sterility in Drosophila.

    PubMed Central

    Sawamura, Kyoichi; Roote, John; Wu, Chung-I; Yamamoto, Masa-Toshi

    2004-01-01

    Recent genetic analyses of closely related species of Drosophila have indicated that hybrid male sterility is the consequence of highly complex synergistic effects among multiple genes, both conspecific and heterospecific. On the contrary, much evidence suggests the presence of major genes causing hybrid female sterility and inviability in the less-related species, D. melanogaster and D. simulans. Does this contrast reflect the genetic distance between species? Or, generally, is the genetic basis of hybrid male sterility more complex than that of hybrid female sterility and inviability? To clarify this point, the D. simulans introgression of the cytological region 34D-36A to the D. melanogaster genome, which causes recessive male sterility, was dissected by recombination, deficiency, and complementation mapping. The 450-kb region between two genes, Suppressor of Hairless and snail, exhibited a strong effect on the sterility. Males are (semi-)sterile if this region of the introgression is made homozygous or hemizygous. But no genes in the region singly cause the sterility; this region has at least two genes, which in combination result in male sterility. Further, the males are less fertile when heterozygous with a larger introgression, which suggests that dominant modifiers enhance the effects of recessive genes of male sterility. Such an epistatic view, even in the less-related species, suggests that the genetic complexity is special to hybrid male sterility. PMID:15020468

  2. Electrolytic silver ion cell sterilizes water supply

    NASA Technical Reports Server (NTRS)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  3. Genomic networks of hybrid sterility.

    PubMed

    Turner, Leslie M; White, Michael A; Tautz, Diethard; Payseur, Bret A

    2014-02-01

    Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities"). The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus) provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL). Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is applicable in a broad

  4. Radiation sterilization of skin allograft

    NASA Astrophysics Data System (ADS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  5. Sterilization surgery - making a decision

    MedlinePlus

    ... medlineplus.gov/ency/article/002138.htm Sterilization surgery - making a decision To use the sharing features on this page, ... about all the options available to you before making the decision to have a sterilization procedure. Alternative Names Deciding ...

  6. The Noble-Abel Stiffened-Gas equation of state

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Métayer, Olivier, E-mail: olivier.lemetayer@univ-amu.fr; Saurel, Richard, E-mail: richard.saurel@univ-amu.fr; RS2N, 371 Chemin de Gaumin, 83640 Saint-Zacharie

    2016-04-15

    Hyperbolic two-phase flow models have shown excellent ability for the resolution of a wide range of applications ranging from interfacial flows to fluid mixtures with several velocities. These models account for waves propagation (acoustic and convective) and consist in hyperbolic systems of partial differential equations. In this context, each phase is compressible and needs an appropriate convex equation of state (EOS). The EOS must be simple enough for intensive computations as well as boundary conditions treatment. It must also be accurate, this being challenging with respect to simplicity. In the present approach, each fluid is governed by a novel EOSmore » named “Noble Abel stiffened gas,” this formulation being a significant improvement of the popular “Stiffened Gas (SG)” EOS. It is a combination of the so-called “Noble-Abel” and “stiffened gas” equations of state that adds repulsive effects to the SG formulation. The determination of the various thermodynamic functions and associated coefficients is the aim of this article. We first use thermodynamic considerations to determine the different state functions such as the specific internal energy, enthalpy, and entropy. Then we propose to determine the associated coefficients for a liquid in the presence of its vapor. The EOS parameters are determined from experimental saturation curves. Some examples of liquid-vapor fluids are examined and associated parameters are computed with the help of the present method. Comparisons between analytical and experimental saturation curves show very good agreement for wide ranges of temperature for both liquid and vapor.« less

  7. Surgical Sterilization, Regret, and Race: Contemporary Patterns*

    PubMed Central

    Shreffler, Karina M.; McQuillan, Julia; Greil, Arthur L.; Johnson, David R.

    2014-01-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4,609 women ages 25 to 45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. PMID:25592919

  8. Coelioscopic and Endoscope-Assisted Sterilization of Chelonians.

    PubMed

    Proença, Laila M; Divers, Stephen J

    2015-09-01

    Elective sterilization is a safe and well-established surgical procedure performed in dogs and cats worldwide. Conversely, chelonian sterilization has been mostly performed therapeutically, because of the intricate anatomy and difficult access to the reproductive organs, and consequently, reproductive problems and diseases remain common. With the advance of veterinary endoscopy, novel techniques of soft tissue prefemoral coelioscopic and endoscope-assisted sterilization have been published, and preventative chelonian sterilization is now a reality. Nevertheless, extrapolations between species should be carefully considered, and further studies are warranted. This article summarizes and describes the current coelioscopic and coelioscope-assisted sterilization techniques for chelonia. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. F(R) cosmology via Noether symmetry and Λ-Chaplygin Gas like model

    NASA Astrophysics Data System (ADS)

    Fazlollahi, H. R.

    2018-06-01

    In this work, we consider f (R) alternative theories of gravity with an eye to Noether symmetry through the gauge theorem. For non-vacuum models, one finds Λ like gravity with energy density of Chaplygin Gas. We also obtain the effective equation of state parameter for corresponding cosmology and scale factor behavior with respect to cosmic time which show that the model provides viable EoS and scale factor with respect to observational data.

  10. Evaluation of new technique of sterilization using biological indicator

    PubMed Central

    Sheth, Nomal Chintan; Rathod, Yogesh V.; Shenoi, Pratima R.; Shori, Deepa D.; Khode, Rajiv T.; Khadse, Amruta P.

    2017-01-01

    Background: A novel technique of sterilization of endodontic files is introduced in this article. Aims: Newly introduced sterilization unit, named “SteriFast” is compared with autoclave and glass bead sterilizer using biological indicator. Materials and Methods: Spore strips of Bacillus pumilus were cultured in nutrient broth. This cultured media was used to contaminate the experimental samples of endodontic files. These contaminated files were sterilized using three different techniques. The sterilized files were transferred into nutrient medium under aseptic condition. The results were observed after 24 h, 48 h, and 7 days. Results: The results showed that autoclave and new sterilization device (SteriFast) showed complete sterilization. The files sterilized using glass bead sterilizer showed bacterial growth (80%). Conclusions: Thus, it proves that autoclave and SteriFast are ideal techniques of sterilization of endodontic files. Glass bead sterilizer does not completely sterilize the files. The article also compares SteriFast and autoclave in other aspects such as its design, basic principle, advantages, and disadvantages. The article also describes features and design of SteriFast, used for all kind of small dental instruments. PMID:29386784

  11. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  12. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  13. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  14. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  15. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat sterilizer. (a) Identification. An endodontic dry heat sterilizer is a device intended to sterilize endodontic...

  16. Electrically charged: An effective mechanism for soft EOS supporting massive neutron star

    NASA Astrophysics Data System (ADS)

    Jing, ZhenZhen; Wen, DeHua; Zhang, XiangDong

    2015-10-01

    The massive neutron star discoverer announced that strange particles, such as hyperons should be ruled out in the neutron star core as the soft Equation of State (EOS) can-not support a massive neutron star. However, many of the nuclear theories and laboratory experiments support that at high density the strange particles will appear and the corresponding EOS of super-dense matters will become soft. This situation promotes a challenge between the astro-observation and nuclear physics. In this work, we introduce an effective mechanism to answer this challenge, that is, if a neutron star is electrically charged, a soft EOS will be equivalently stiffened and thus can support a massive neutron star. By employing a representative soft EOS, it is found that in order to obtain an evident effect on the EOS and thus increasing the maximum stellar mass by the electrostatic field, the total net charge should be in an order of 1020 C. Moreover, by comparing the results of two kind of charge distributions, it is found that even for different distributions, a similar total charge: ~ 2.3 × 1020 C is needed to support a ~ 2.0 M ⊙ neutron star.

  17. Rendering plant emissions of volatile organic compounds during sterilization and cooking processes.

    PubMed

    Bhatti, Z A; Maqbool, F; Langenhove, H V

    2014-01-01

    The rendering process emits odorous volatile compounds in the atmosphere; if these volatile organic compounds (VOCs) are not handled properly they can cause a serious environmental problem. During this process not all emitted compounds are odorous and hazardous but some of them have been found associated with health problems. Samples were collected in the plastic bags from the Arnout rendering plant. In this study, VOCs emission from two different processes (cooking and sterilization) was compared. For the analysis of various emitted compounds, gas chromatograph and mass spectrophotometer were used. A sterilization process was added in the rendering plant to inactivate the prion protein from meat bone meal prepared during the rendering process. The identification of mass spectrum was performed by using a mass spectral database system. The most odorous classes of compounds identified were aliphatic hydrocarbons (HCs) (29.24%), furans (28.74%), aromatic HCs (18.32%), most important sulphur-containing compounds (12.15%), aldehyde (10.91%) and ketones (0.60%). Emissions released during cooking and sterilization were 32.73 x 10(2) and 36.85 x 10(2) mg m(-3), respectively. In this study, it was observed that after the addition of the sterilization process VOCs' emissions were increased. A total of 87 mg m(-3) dimethyl disulphide (DMS) was detected only during the cooking process, whereas dimethly trisulphide (DMTS) was detected in both cooking (300 mg m(-3)) and sterilization (301 mg m(-3)) processes. About 11 mg m3 of DMS was detected during the cooking process, which was a small concentration compared with 299 mg m(-3) found during the sterilization process. At high temperature and pressure, DMTS and DMS were released more than any other sulphur-containing compounds. A condenser was applied to control the combined emission and it was successful in the reduction of VOCs to 22.83 x 10(2) mg m(-3) (67% reduction).

  18. EOS Reference Handbook 1999: A Guide to NASA's Earth Science Enterprise and the Earth Observing System

    NASA Technical Reports Server (NTRS)

    King, M. D. (Editor); Greenstone, R. (Editor)

    2000-01-01

    The content of this handbook includes Earth Science Enterprise; The Earth Observing System; EOS Data and Information System (EOSDIS); Data and Information Policy; Pathfinder Data Sets; Earth Science Information Partners and the Working Prototype-Federation; EOS Data Quality: Calibration and Validation; Education Programs; International Cooperation; Interagency Coordination; Mission Elements; EOS Instruments; EOS Interdisciplinary Science Investigations; and Points-of-Contact.

  19. Sterilization effects of atmospheric cold plasma brush

    NASA Astrophysics Data System (ADS)

    Yu, Q. S.; Huang, C.; Hsieh, F.-H.; Huff, H.; Duan, Yixiang

    2006-01-01

    This study investigated the sterilization effects of a brush-shaped plasma created at one atmospheric pressure. A population of 1.0×104-1.0×105 Escherichia coli or Micrococcus luteus bacteria was seeded in filter paper media and then subjected to Ar and/or Ar +O2 plasmas. A complete kill of the Micrococcus luteus required about 3 min argon plasma exposures. With oxygen addition into the argon plasma gas streams, a complete kill of the bacteria needed only less than 1 min plasma exposure for Micrococcus luteus and about 2 min exposure for Escherichia coli. The plasma treatment effects on the different bacteria cell structures were examined using scanning electron microscopy.

  20. Earthquakes and depleted gas reservoirs: which comes first?

    NASA Astrophysics Data System (ADS)

    Mucciarelli, M.; Donda, F.; Valensise, G.

    2015-10-01

    While scientists are paying increasing attention to the seismicity potentially induced by hydrocarbon exploitation, so far, little is known about the reverse problem, i.e. the impact of active faulting and earthquakes on hydrocarbon reservoirs. The 20 and 29 May 2012 earthquakes in Emilia, northern Italy (Mw 6.1 and 6.0), raised concerns among the public for being possibly human-induced, but also shed light on the possible use of gas wells as a marker of the seismogenic potential of an active fold and thrust belt. We compared the location, depth and production history of 455 gas wells drilled along the Ferrara-Romagna arc, a large hydrocarbon reserve in the southeastern Po Plain (northern Italy), with the location of the inferred surface projection of the causative faults of the 2012 Emilia earthquakes and of two pre-instrumental damaging earthquakes. We found that these earthquake sources fall within a cluster of sterile wells, surrounded by productive wells at a few kilometres' distance. Since the geology of the productive and sterile areas is quite similar, we suggest that past earthquakes caused the loss of all natural gas from the potential reservoirs lying above their causative faults. To validate our hypothesis we performed two different statistical tests (binomial and Monte Carlo) on the relative distribution of productive and sterile wells, with respect to seismogenic faults. Our findings have important practical implications: (1) they may allow major seismogenic sources to be singled out within large active thrust systems; (2) they suggest that reservoirs hosted in smaller anticlines are more likely to be intact; and (3) they also suggest that in order to minimize the hazard of triggering significant earthquakes, all new gas storage facilities should use exploited reservoirs rather than sterile hydrocarbon traps or aquifers.

  1. Observations on female sterilization in Chile.

    PubMed

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical

  2. STUDIES ON HOUSEFLIES, STERILIZED WITH X RAYS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sacca, G.

    1961-01-01

    Experiments were conducted on radiosterilization of male houseflies (Musca domestica). The females are monogamous, so that all the females mating with sterile males lay sterile eggs. Tests with 24-kv x rays showed that the most satisfactory method of sterilizing male houseflies consists of irradiating the pupa with 3000 r 2 to 3 days before emergence. The mortality of the irradiated pupae was not appreciably increased and the flies emerging from them were normal in appearance, viability, longevity, and sexual activity. When the irradiated males were mated with normal females, sterility was 100% complete. However, there was a slight tendency formore » females mated with irradiated males to remate with normal males. Sterile males successfully competed with normal males in search of females, and when they were present in overwhelming numbers succeeded in mating with most of the females, leaving them sterile. (H.H.D.)« less

  3. Surgical sterilization, regret, and race: contemporary patterns.

    PubMed

    Shreffler, Karina M; McQuillan, Julia; Greil, Arthur L; Johnson, David R

    2015-03-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4592 women ages 25-45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Mission operations concepts for Earth Observing System (EOS)

    NASA Technical Reports Server (NTRS)

    Kelly, Angelita C.; Taylor, Thomas D.; Hawkins, Frederick J.

    1991-01-01

    Mission operation concepts are described which are being used to evaluate and influence space and ground system designs and architectures with the goal of achieving successful, efficient, and cost-effective Earth Observing System (EOS) operations. Emphasis is given to the general characteristics and concepts developed for the EOS Space Measurement System, which uses a new series of polar-orbiting observatories. Data rates are given for various instruments. Some of the operations concepts which require a total system view are also examined, including command operations, data processing, data accountability, data archival, prelaunch testing and readiness, launch, performance monitoring and assessment, contingency operations, flight software maintenance, and security.

  5. XML DTD and Schemas for HDF-EOS

    NASA Technical Reports Server (NTRS)

    Ullman, Richard; Yang, Jingli

    2008-01-01

    An Extensible Markup Language (XML) document type definition (DTD) standard for the structure and contents of HDF-EOS files and their contents, and an equivalent standard in the form of schemas, have been developed.

  6. Bridging EO Research, Operations and Collaborative Learning

    NASA Astrophysics Data System (ADS)

    Scarth, Peter

    2016-04-01

    Building flexible and responsive processing and delivery systems is key to getting EO information used by researchers, policy agents and the public. There are typically three distinct processes we tackle to get product uptake: undertake research, operationalise the validated research, and deliver information and garner feedback in an appropriate way. In many cases however, the gaps between these process elements are large and lead to poor outcomes. Good research may be "lost" and not adopted, there may be resistance to uptake by government or NGOs of significantly better operational products based on EO data, and lack of accessibility means that there is no use of interactive science outputs to improve cross disciplinary science or to start a dialog with citizens. So one of the the most important tasks, if we wish to have broad uptake of EO information and accelerate further research, is to link these processes together in a formal but flexible way. One of the ways to operationalize research output is by building a platform that can take research code and scale it across much larger areas. In remote sensing, this is typically a system that has access to current and historical corrected imagery with a processing pipeline built over the top. To reduce the demand on high level scientific programmers and allowing cross disciplinary researchers to hack and play and refine, this pipeline needs to be easy to use, collaborative and link to existing tools to encourage code experimentation and reuse. It is also critical to have efficient, tight integration with information delivery and extension components so that the science relevant to your user is available quickly and efficiently. The rapid expansion of open data licensing has helped this process, but building top-down web portals and tools without flexibility and regard for end user needs has limited the use of EO information in many areas. This research reports on the operalization of a scale independent time series

  7. Supercritical carbon dioxide-based sterilization of decellularized heart valves

    PubMed Central

    Hennessy, Ryan S.; Jana, Soumen; Tefft, Brandon J.; Helder, Meghana R.; Young, Melissa D.; Hennessy, Rebecca R.; Stoyles, Nicholas J.; Lerman, Amir

    2017-01-01

    Objective The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Background Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Methods Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Results Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Conclusions Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Summary Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated

  8. Supercritical carbon dioxide-based sterilization of decellularized heart valves.

    PubMed

    Hennessy, Ryan S; Jana, Soumen; Tefft, Brandon J; Helder, Meghana R; Young, Melissa D; Hennessy, Rebecca R; Stoyles, Nicholas J; Lerman, Amir

    2017-02-01

    The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe

  9. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION AT...

  10. Capitalizing on Education and Outreach (E/O) Expertise to Broaden Impacts (Invited)

    NASA Astrophysics Data System (ADS)

    Girguis, P. R.; Herren, C.; Decharon, A.

    2010-12-01

    Academic scientists have a number of avenues through which they can participate in education and outreach (E/O) programs to address the mandate for broader impacts. As a principal investigator (PI) at an R1 institution, I (Girguis) have both developed and participated in a variety of E/O programs that span the spectrum from ad hoc groups (e.g. informal high school internships in my laboratory) to regional efforts (e.g. Harvard’s Microbial Science Initiative) and national organizations (e.g. RIDGE 2000; Centers for Ocean Sciences Education Excellence, COSEE). Each of these E/O efforts required varying degrees of preparation and participation by my laboratory members (e.g. graduate students and postdoctoral researchers) and I, and yielded different outcomes and products. Ad hoc programs typically require a higher degree of effort on the part of the PI and have a high, though local, impact on the audience. These programs can be personally rewarding for the PI, who likely has played a major role in developing the program. In contrast, working with regional and national groups requires PIs to understand the nature of each program to successfully integrate within the existing structure. The net time and effort invested by scientists in larger-scale E/O efforts may be equal to that of ad hoc programs. However, interaction with high-quality program facilitators ensures that the outcomes are grounded in best educational practices and that outputs are educator-vetted, well maintained (online or through publications), and broadly disseminated. In addition, program facilitators also collect and analyze evaluation data to provide constructive feedback to PIs, enabling the latter to refine their presentation styles and content levels to improve future E/O efforts. Thus involvement with larger programs can effectively broaden one’s impact. During this presentation, we will present one scientist’s perspective on the advantages and limitations of these different modes of E/O

  11. Study on C-S and P-R EOS in pseudo-potential lattice Boltzmann model for two-phase flows

    NASA Astrophysics Data System (ADS)

    Peng, Yong; Mao, Yun Fei; Wang, Bo; Xie, Bo

    Equations of State (EOS) is crucial in simulating multiphase flows by the pseudo-potential lattice Boltzmann method (LBM). In the present study, the Peng and Robinson (P-R) and Carnahan and Starling (C-S) EOS in the pseudo-potential LBM with Exact Difference Method (EDM) scheme for two-phase flows have been compared. Both of P-R and C-S EOS have been used to study the two-phase separation, surface tension, the maximum two-phase density ratio and spurious currents. The study shows that both of P-R and C-S EOS agree with the analytical solutions although P-R EOS may perform better. The prediction of liquid phase by P-R EOS is more accurate than that of air phase and the contrary is true for C-S EOS. Predictions by both of EOS conform with the Laplace’s law. Besides, adjustment of surface tension is achieved by adjusting T. The P-R EOS can achieve larger maximum density ratio than C-S EOS under the same τ. Besides, no matter the C-S EOS or the P-R EOS, if τ tends to 0.5, the computation is prone to numerical instability. The maximum spurious current for P-R is larger than that of C-S. The multiple-relaxation-time LBM still can improve obviously the numerical stability and can achieve larger maximum density ratio.

  12. Attitude Accuracy Study for the Earth Observing System (EOS) AM-1 Spacecraft

    NASA Technical Reports Server (NTRS)

    Lesikar, James D., II; Garrick, Joseph C.

    1996-01-01

    Earth Observing System (EOS) spacecraft will take measurements of the Earth's clouds, oceans, atmosphere, land, and radiation balance. These EOS spacecraft are part of the National Aeronautics and Space Administration's Mission to Planet Earth, and consist of several series of satellites, with each series specializing in a particular class of observations. This paper focuses on the EOS AM-1 spacecraft, which is the first of three satellites constituting the EOS AM series (morning equatorial crossing) and the initial spacecraft of the EOS program. EOS AM-1 has a stringent onboard attitude knowledge requirement, of 36/41/44 arc seconds (3 sigma) in yaw/roll/pitch, respectively. During normal mission operations, attitude is determined onboard using an extended Kalman sequential filter via measurements from two charge coupled device (CCD) star trackers, one Fine Sun Sensor, and an Inertial Rate Unit. The attitude determination error analysis system (ADEAS) was used to model the spacecraft and mission profile, and in a worst case scenario with only one star tracker in operation, the attitude uncertainty was 9.7/ll.5/12.2 arc seconds (3 sigma) in yaw/roll/pitch. The quoted result assumed the spacecraft was in nominal attitude, using only the 1-rotation per orbit motion of the spacecraft about the pitch axis for calibration of the gyro biases. Deviations from the nominal attitude would show greater attitude uncertainties, unless calibration maneuvers which roll and/or yaw the spacecraft have been performed. This permits computation of the gyro misalignments, and the attitude knowledge requirement would remain satisfied.

  13. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50... GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207 Sterilization by hysterectomy. (a) Programs or projects to which this subpart applies shall not perform or...

  14. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 441.255 Section 441.255 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a...

  15. An evaluation of beta-propiolactone for the sterilization of fermentation media.

    PubMed

    HIMMELFARB, P; READ, R B; LITSKY, W

    1961-11-01

    Twenty-five bacterial species were cultured in basal broth plus 1 of 19 different carbohydrates which were sterilized by Seitz filtration, autoclaving (112 C, 10 min), or exposure to 0.2% beta-propiolactone (BPL). No significant differences were found either in the visual observations for acid and gas, pH, or titrable acidity determinations after 3 days of incubation with any of the three preparations tested. An effort was made to further determine the effect of BPL and heat on carbohydrates by assaying for glucose before and after treatment. Results indicated that glucose was not degraded by 0.2% BPL, however, it was shown that autoclave temperatures caused extensive degradation. Statistical treatment of the results from Warburg studies indicated that BPL-treated glucose showed no appreciable toxic effects, although the actual oxygen uptake was not as great as with Seitz- or autoclave-treated glucose. The application of the BPL sterilization process was discussed.

  16. Federally funded sterilization: time to rethink policy?

    PubMed

    Borrero, Sonya; Zite, Nikki; Creinin, Mitchell D

    2012-10-01

    In the 1970s, concern about coercive sterilization of low-income and minority women in the United States led the US Department of Health, Education, and Welfare to create strict regulations for federally funded sterilization procedures. Although these policies were instituted to secure informed consent and protect women from involuntary sterilization, there are significant data indicating that these policies may not, in fact, ensure that consent is truly informed and, further, may prevent many low-income women from getting a desired sterilization procedure. Given the alarmingly high rates of unintended pregnancy in the United States, especially among low-income populations, we feel that restrictive federal sterilization policies should be reexamined and modified to simultaneously ensure informed decision-making and honor women's reproductive choices.

  17. Federally Funded Sterilization: Time to Rethink Policy?

    PubMed Central

    Zite, Nikki; Creinin, Mitchell D.

    2012-01-01

    In the 1970s, concern about coercive sterilization of low-income and minority women in the United States led the US Department of Health, Education, and Welfare to create strict regulations for federally funded sterilization procedures. Although these policies were instituted to secure informed consent and protect women from involuntary sterilization, there are significant data indicating that these policies may not, in fact, ensure that consent is truly informed and, further, may prevent many low-income women from getting a desired sterilization procedure. Given the alarmingly high rates of unintended pregnancy in the United States, especially among low-income populations, we feel that restrictive federal sterilization policies should be reexamined and modified to simultaneously ensure informed decision-making and honor women’s reproductive choices. PMID:22897531

  18. Genomic Networks of Hybrid Sterility

    PubMed Central

    Turner, Leslie M.; White, Michael A.; Tautz, Diethard; Payseur, Bret A.

    2014-01-01

    Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci (“Dobzhansky-Muller incompatibilities”). The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus) provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL). Many trans eQTL cluster into eleven ‘hotspots,’ seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL—but not cis eQTL—were substantially lower when mapping was restricted to a ‘fertile’ subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  19. Volume-translated cubic EoS and PC-SAFT density models and a free volume-based viscosity model for hydrocarbons at extreme temperature and pressure conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burgess, Ward A.; Tapriyal, Deepak; Morreale, Bryan D.

    2013-12-01

    This research focuses on providing the petroleum reservoir engineering community with robust models of hydrocarbon density and viscosity at the extreme temperature and pressure conditions (up to 533 K and 276 MPa, respectively) characteristic of ultra-deep reservoirs, such as those associated with the deepwater wells in the Gulf of Mexico. Our strategy is to base the volume-translated (VT) Peng–Robinson (PR) and Soave–Redlich–Kwong (SRK) cubic equations of state (EoSs) and perturbed-chain, statistical associating fluid theory (PC-SAFT) on an extensive data base of high temperature (278–533 K), high pressure (6.9–276 MPa) density rather than fitting the models to low pressure saturated liquidmore » density data. This high-temperature, high-pressure (HTHP) data base consists of literature data for hydrocarbons ranging from methane to C{sub 40}. The three new models developed in this work, HTHP VT-PR EoS, HTHP VT-SRK EoS, and hybrid PC-SAFT, yield mean absolute percent deviation values (MAPD) for HTHP hydrocarbon density of ~2.0%, ~1.5%, and <1.0%, respectively. An effort was also made to provide accurate hydrocarbon viscosity models based on literature data. Viscosity values are estimated with the frictional theory (f-theory) and free volume (FV) theory of viscosity. The best results were obtained when the PC-SAFT equation was used to obtain both the attractive and repulsive pressure inputs to f-theory, and the density input to FV theory. Both viscosity models provide accurate results at pressures to 100 MPa but experimental and model results can deviate by more than 25% at pressures above 200 MPa.« less

  20. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  1. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  2. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  3. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  4. Superfluid Fermi atomic gas as a quantum simulator for the study of the neutron-star equation of state in the low-density region

    NASA Astrophysics Data System (ADS)

    van Wyk, Pieter; Tajima, Hiroyuki; Inotani, Daisuke; Ohnishi, Akira; Ohashi, Yoji

    2018-01-01

    We propose a theoretical idea to use an ultracold Fermi gas as a quantum simulator for the study of the low-density region of a neutron-star interior. Our idea is different from the standard quantum simulator that heads for perfect replication of another system, such as the Hubbard model discussed in high-Tc cuprates. Instead, we use the similarity between two systems and theoretically make up for the difference between them. That is, (1) we first show that the strong-coupling theory developed by Nozières and Schmitt-Rink (NSR) can quantitatively explain the recent experiment on the equation of state (EoS) in a 6Li superfluid Fermi gas in the BCS (Bardeen-Cooper-Schrieffer) unitary limit far below the superfluid phase-transition temperature Tc. This region is considered to be very similar to the low-density region (crust regime) of a neutron star (where a nearly unitary s -wave neutron superfluid is expected). (2) We then theoretically compensate the difference that, while the effective range reff is negligibly small in a superfluid 6Li Fermi gas, it cannot be ignored (reff=2.7 fm) in a neutron star, by extending the NSR theory to include effects of reff. The calculated EoS when reff=2.7 fm is shown to agree well with the previous neutron-star EoS in the low-density region predicted in nuclear physics. Our idea indicates that an ultracold atomic gas may more flexibly be used as a quantum simulator for the study of other complicated quantum many-body systems, when we use not only the experimental high tunability, but also the recent theoretical development in this field. Since it is difficult to directly observe a neutron-star interior, our idea would provide a useful approach to the exploration for this mysterious astronomical object.

  5. Development of a PPT for the EO-1 Spacecraft

    NASA Technical Reports Server (NTRS)

    Benson, Scott W.; Arrington, Lynn A.; Hoskins, W. Andrew; Meckel, Nicole J.

    2000-01-01

    A Pulsed Plasma Thruster (PPT) has been developed for use in a technology demonstration flight experiment on the Earth Observing 1 (EO-1) New Millennium Program mission. The thruster replaces the spacecraft pitch axis momentum wheel for control and momentum management during an experiment of a minimum three-day duration. The EO-1 PPT configuration is a combination of new technology and design heritage from similar systems flown in the 1970's and 1980's. Acceptance testing of the protoflight unit has validated readiness for flight, and integration with the spacecraft, including initial combined testing, has been completed. The thruster provides a range of capability from 90 microN-sec impulse bit at 650 sec specific impulse for 12 W input power, through 860 microN-sec impulse bit at 1400 see specific impulse for 70 W input power. Development of this thruster reinitiates technology research and development and re-establishes an industry base for production of flight hardware. This paper reviews the EO-1 PPT development, including technology selection, design and fabrication, acceptance testing, and initial spacecraft integration and test.

  6. Characteristics of Surface Sterilization using ECR Plasma

    NASA Astrophysics Data System (ADS)

    Yonesu, Akira; Hara, Kazufumi; Nishikawa, Tatsuya; Hayashi, Nobuya

    2015-09-01

    Plasma sterilization techniques have superior characteristics such as a short treatment times, non-toxicity and low thermal damages on the sterilized materials. In plasma sterilization, microorganisms can be sterilized by active radicals, energetic charged particles, and vacuum UV radiation. The influence of each factor depends on the plasma operating parameters. Microwave discharges under the electron cyclotron resonance (ECR) condition produce higher electron temperature and density plasma as compared with other plasma generation techniques. In the present study, characteristics of surface sterilization using ECR plasma have been investigated.The experiment was performed in the vacuum chamber which contains a magnet holder. A pair of rectangular Sm-Co permanent magnets is aligned parallel to each other within the magnet holder. The region of the magnetic field for ECR exists near the magnet holder surface. When the microwave is introduced into the vacuum chamber, a ECR plasma is produced around surface of the magnet holder. High energy electrons and oxygen radicals were observed at ECR zone by electric probe method and optical spectroscopic method. Biological indicators (B.I.) having spore of 106 was sterilized in 2min for oxygen discharge. The temperature of the B.I. installation position was about 55°. The sterilization was achieved by the effect of oxygen radicals and high energy electrons.

  7. Expression of sunflower cytoplasmic male sterility-associated open reading frame, orfH522 induces male sterility in transgenic tobacco plants.

    PubMed

    Nizampatnam, Narasimha Rao; Doodhi, Harinath; Kalinati Narasimhan, Yamini; Mulpuri, Sujatha; Viswanathaswamy, Dinesh Kumar

    2009-03-01

    Sterility in the universally exploited PET1-CMS system of sunflower is associated with the expression of orfH522, a novel mitochondrial gene. Definitive evidence that ORFH522 is directly responsible for male sterility is lacking. To test the hypothesis that ORFH522 is sufficient to induce male sterility, a set of chimeric constructs were developed. The cDNA of orfH522 was cloned in-frame with yeast coxIV pre-sequence, and was expressed under tapetum-specific promoter TA29 (construct designated as TCON). For developing control vectors, orfH522 was cloned without the transit peptide under TA29 promoter (TON) or orfH522 was cloned with or without transit peptide under the constitutive CaMV35S promoter (SCOP and SOP). Among several independent transformants obtained with each of the gene cassettes, one third of the transgenics (6/17) with TCON were completely male sterile while more than 10 independent transformants obtained with each of the control vectors were fertile. The male sterile plants were morphologically similar to fertile plants, but had anthers that remained below the stigmatic surface at anthesis. RT-PCR analysis of the sterile plants confirmed the anther-specific expression of orfH522 and bright-field microscopy demonstrated ablation of the tapetal cell layer. Premature DNA fragmentation and programmed cell death was observed at meiosis stage in the anthers of sterile plants. Stable transmission of induced male sterility trait was confirmed in test cross progeny. This constitutes the first report at demonstrating the induction of male sterility by introducing orfH522 gene that could be useful for genetic engineering of male sterility.

  8. Future Perspective and Long-Term Strategy of the Indian EO Programme

    NASA Astrophysics Data System (ADS)

    Rao, Mukund; Jayaraman, V.; Sridhara Murthi, K. R.; Kasturirangan, K.

    EO technology development will continue to have profound effects on spatial information activities, as we are seeing it today - the changing demand of GIS technology to understanding processes around us and its representation as maps. In the longer term, information needs will drive further RS and GIS technological developments - creating stringent demands for technology solutions for spatial data capture, integration and representation. The emergence of Spatial Business from the highly volatile and dynamic synergy of information, technology and access will see a truly Spatial Society. EO will have a major impact on day-to-day life of nations, communities and even an individual. It will become the One-stop source for information - spatial information at that - thus enabling not only development oriented activities but also Business GIS, quality research and Info-savvy communities. Internationally, there will be a mix of Government and Commercial satellites vying to provide information services to a wide variety of users. EO satellites are also becoming smaller, efficient and less costlier. Almost 5-6 commercial systems will orbit around the Earth in the foreseeable future to generate massive, seamless archives of high-resolution panchromatic and multispectral images - almost reducing the need for aerial surveys for photography and mapping. Reaching resolution of cm level and covering narrower and more spectral bands, the trend is to IMAGE the Earth in its entirety and organize Image Infrastructures. The race will be to imaginatively capture the market with the fullest archive of the globe and cater to any imaging demand of users. One will also see efficient satellite operations that will enable imaging any part of the globe with minimum turn-around time - reaching concepts of IMAGING ON DEMAND. The need of the hour is looking forward now towards how the EO technology can adapt itself to the changing scenario and the steps to be taken to sustain use of EO data it in

  9. Hysteroscopic Sterilization: History and Current Methods

    PubMed Central

    Greenberg, James A

    2008-01-01

    For many practicing obstetrician-gynecologists, tubal ligation was the gold standard by which female sterilization techniques were measured. Yet gynecologic surgeons have simultaneously sought to occlude the fallopian tubes transcervically to avoid discomfort and complications associated with transabdominal approaches. In this review, the history of transcervical sterilization is discussed. Past, current, and upcoming techniques are reviewed. This article focuses on interval sterilization techniques, thus removing post-vaginal and post-cesarean delivery tubal ligations from the discussion. PMID:19015762

  10. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene

    PubMed Central

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-01-01

    The breeding and large-scale adoption of hybrid seeds is an important achievement in agriculture. Rice hybrid seed production uses cytoplasmic male sterile lines or photoperiod/thermo-sensitive genic male sterile lines (PTGMS) as female parent. Cytoplasmic male sterile lines are propagated via cross-pollination by corresponding maintainer lines, whereas PTGMS lines are propagated via self-pollination under environmental conditions restoring male fertility. Despite huge successes, both systems have their intrinsic drawbacks. Here, we constructed a rice male sterility system using a nuclear gene named Oryza sativa No Pollen 1 (OsNP1). OsNP1 encodes a putative glucose–methanol–choline oxidoreductase regulating tapetum degeneration and pollen exine formation; it is specifically expressed in the tapetum and miscrospores. The osnp1 mutant plant displays normal vegetative growth but complete male sterility insensitive to environmental conditions. OsNP1 was coupled with an α-amylase gene to devitalize transgenic pollen and the red fluorescence protein (DsRed) gene to mark transgenic seed and transformed into the osnp1 mutant. Self-pollination of the transgenic plant carrying a single hemizygous transgene produced nontransgenic male sterile and transgenic fertile seeds in 1:1 ratio that can be sorted out based on the red fluorescence coded by DsRed. Cross-pollination of the fertile transgenic plants to the nontransgenic male sterile plants propagated the male sterile seeds of high purity. The male sterile line was crossed with ∼1,200 individual rice germplasms available. Approximately 85% of the F1s outperformed their parents in per plant yield, and 10% out-yielded the best local cultivars, indicating that the technology is promising in hybrid rice breeding and production. PMID:27864513

  11. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene.

    PubMed

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-12-06

    The breeding and large-scale adoption of hybrid seeds is an important achievement in agriculture. Rice hybrid seed production uses cytoplasmic male sterile lines or photoperiod/thermo-sensitive genic male sterile lines (PTGMS) as female parent. Cytoplasmic male sterile lines are propagated via cross-pollination by corresponding maintainer lines, whereas PTGMS lines are propagated via self-pollination under environmental conditions restoring male fertility. Despite huge successes, both systems have their intrinsic drawbacks. Here, we constructed a rice male sterility system using a nuclear gene named Oryza sativa No Pollen 1 (OsNP1). OsNP1 encodes a putative glucose-methanol-choline oxidoreductase regulating tapetum degeneration and pollen exine formation; it is specifically expressed in the tapetum and miscrospores. The osnp1 mutant plant displays normal vegetative growth but complete male sterility insensitive to environmental conditions. OsNP1 was coupled with an α-amylase gene to devitalize transgenic pollen and the red fluorescence protein (DsRed) gene to mark transgenic seed and transformed into the osnp1 mutant. Self-pollination of the transgenic plant carrying a single hemizygous transgene produced nontransgenic male sterile and transgenic fertile seeds in 1:1 ratio that can be sorted out based on the red fluorescence coded by DsRed Cross-pollination of the fertile transgenic plants to the nontransgenic male sterile plants propagated the male sterile seeds of high purity. The male sterile line was crossed with ∼1,200 individual rice germplasms available. Approximately 85% of the F1s outperformed their parents in per plant yield, and 10% out-yielded the best local cultivars, indicating that the technology is promising in hybrid rice breeding and production.

  12. Component Selection for Sterile Compounding.

    PubMed

    Dilzer, Richard H

    2017-01-01

    This article describes the factors to consider, as well as the process of proper component selection, for use in preparing compounded sterile preparations. Special emphasis is placed on individual chemical factors that may impact a preparation's accuracy and potency. Values reported in a typical certificate of analysis are discussed, including methods of identifying any required adjustments to a master formulation or compounding record during the compounding of sterile preparations. Proper screening of the certificate of analysis, the Safety Data Sheet, procedural documentation, and the filing of all certificates of conformance are crucial to the operation of a sterile compounding facility. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  13. The Utility of Gas Gun Experiments in Developing Equations of State

    NASA Astrophysics Data System (ADS)

    Pittman, Emily; Hagelberg, Carl; Ramsey, Scott

    2016-11-01

    Gas gun experiments have the potential to investigate material properties in various well defined shock conditions, making them a valuable research tool for the development of equations of state (EOS) and material response under shock loading. Gas guns have the ability to create shocks for loading to pressures ranging from MPa to GPa. A variety of diagnostics techniques can be used to gather data from gas gun experiments; resulting data from these experiments is applicable to many fields of study. The focus of this set of experiments is the development of data on the Hugoniot for the overdriven products EOS of PBX 9501 to extend data from which current computational EOS models draw. This series of shots was conducted by M-9 using the two-stage gas-guns at LANL and aimed to gather data within the 30-120 GPa pressure regime. The experiment was replicated using FLAG, a Langrangian multiphysics code, using a one-dimensional setup which employs the Wescott Stewart Davis (WSD) reactive burn model. Prior to this series, data did not extend into this higher range, so the new data allowed for the model to be re-evaluated. A comparison of the results to the experimental data reveals that the model is a good fit to the data below 40 GPa. However, the model did not fall within the error bars for pressures above this region. This is an indication that the material models or burn model could be modified to better match the data.

  14. Sterilization of Extracted Human Teeth.

    ERIC Educational Resources Information Center

    Pantera, Eugene A., Jr.; Schuster, George S.

    1990-01-01

    At present, there is no specific recommendation for sterilization of extracted human teeth used in dental technique courses. The purpose of this study was to determine whether autoclaving would be effective in the sterilization of extracted teeth without compromising the characteristics that make their use in clinical simulations desirable. (MLW)

  15. Sterilization of instruments in solar ovens.

    PubMed

    Jørgensen, A F; Nøhr, K; Boisen, F; Nøhr, J

    2002-01-01

    The sterilization of instruments in rural health clinics in less developed countries is an increasing problem as chemical methods can no longer be recommended and fuel wood is becoming increasingly scarce. It seems obvious, therefore, to utilize solar energy for sterilization purposes. A solar oven was designed and manufactured using local materials and simple tools. It was tested by physical, chemical and microbiological methods and, after successful testing, installed in a rural clinic. The oven was able to generate temperatures above 180 degrees C. On days with direct sunlight the oven fulfilled the international recommendations for hot air sterilization. The chemical indicators, Browne's tubes type 3 and 5, also changed colour. It was difficult to reach the right value for the sterilization effect during months with a low sun position. A moveable oven, or two ovens, must be installed to solve this problem. The solar oven has proven to be a realistic method for the sterilization of instruments. The solar oven is easy to make and use. It saves fuel and can be used in most tropical areas.

  16. Radar E-O image fusion

    NASA Technical Reports Server (NTRS)

    Oneil, William F.

    1993-01-01

    The fusion of radar and electro-optic (E-O) sensor images presents unique challenges. The two sensors measure different properties of the real three-dimensional (3-D) world. Forming the sensor outputs into a common format does not mask these differences. In this paper, the conditions under which fusion of the two sensor signals is possible are explored. The program currently planned to investigate this problem is briefly discussed.

  17. The EOS Aura Mission

    NASA Technical Reports Server (NTRS)

    Schoebert, Mark R.; Douglass, A. R.; Hilsenrath, E.; Bhartia, P. K.; Barnett, J.; Gille, J.; Beer, R.; Gunson, M.; Waters, J.; Levelt, P. F.

    2004-01-01

    The Earth Observing System (EOS) Aura satellite is scheduled to launch in the second quarter of 2004. The Aura mission is designed to attack three science questions: (1) Is the ozone layer recovering as expected? (2) What are the sources and processes that control tropospheric pollutants? (3) What is the quantitative impact of constituents on climate change? Aura will answer these questions by globally measuring a comprehensive set of trace gases and aerosols at high vertical and horizontal resolution. Fig. 1 shows the Aura spacecraft and its four instruments.

  18. Eos Chaos Rocks

    NASA Technical Reports Server (NTRS)

    2006-01-01

    11 January 2006 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows light-toned, layered rock outcrops in Eos Chaos, located near the east end of the Valles Marineris trough system. The outcrops occur in the form of a distinct, circular butte (upper half of image) and a high slope (lower half of image). The rocks might be sedimentary rocks, similar to those found elsewhere exposed in the Valles Marineris system and the chaotic terrain to the east of the region.

    Location near: 12.9oS, 49.5oW Image width: 3 km (1.9 mi) Illumination from: lower left Season: Southern Summer

  19. Downlink Probability Density Functions for EOS-McMurdo Sound

    NASA Technical Reports Server (NTRS)

    Christopher, P.; Jackson, A. H.

    1996-01-01

    The visibility times and communication link dynamics for the Earth Observations Satellite (EOS)-McMurdo Sound direct downlinks have been studied. The 16 day EOS periodicity may be shown with the Goddard Trajectory Determination System (GTDS) and the entire 16 day period should be simulated for representative link statistics. We desire many attributes of the downlink, however, and a faster orbital determination method is desirable. We use the method of osculating elements for speed and accuracy in simulating the EOS orbit. The accuracy of the method of osculating elements is demonstrated by closely reproducing the observed 16 day Landsat periodicity. An autocorrelation function method is used to show the correlation spike at 16 days. The entire 16 day record of passes over McMurdo Sound is then used to generate statistics for innage time, outage time, elevation angle, antenna angle rates, and propagation loss. The levation angle probability density function is compared with 1967 analytic approximation which has been used for medium to high altitude satellites. One practical result of this comparison is seen to be the rare occurrence of zenith passes. The new result is functionally different than the earlier result, with a heavy emphasis on low elevation angles. EOS is one of a large class of sun synchronous satellites which may be downlinked to McMurdo Sound. We examine delay statistics for an entire group of sun synchronous satellites ranging from 400 km to 1000 km altitude. Outage probability density function results are presented three dimensionally.

  20. NASA SNPP SIPS - Following in the Path of EOS

    NASA Technical Reports Server (NTRS)

    Behnke, Jeanne; Hall, Alfreda; Ho, Evelyn

    2016-01-01

    NASA's Earth Science Data Information System (ESDIS) Project has been operating NASA's Suomi National Polar-Orbiting Partnership (SNPP) Science Data Segment (SDS) since the launch in October 2011. At launch, the SDS focused primarily on the evaluation of Sensor Data Records (SDRs) and Environmental Data Records (EDRs) produced by the Joint Polar Satellite System (JPSS), a National Oceanic and Atmosphere Administration (NOAA) Program, as to their suitability for Earth system science. During the summer of 2014, NASA transitioned to the production of standard Earth Observing System (EOS)-like science products for all instruments aboard Suomi NPP. The five Science Investigator-led Processing Systems (SIPS): Land, Ocean, Atmosphere, Ozone, and Sounder were established to produce the NASA SNPP standard Level 1, Level 2, and global Level 3 products developed by the SNPP Science Teams and to provide the products to NASA's Distributed Active Archive Centers (DAACs) for archive and distribution to the user community. The processing, archiving and distribution of data from NASA's Clouds and the Earth's Radiant Energy System (CERES) and Ozone Mapper/Profiler Suite (OMPS) Limb instruments will continue. With the implementation of the JPSS Block 2 architecture and the launch of JPSS-1, the SDS will receive SNPP data in near real-time via the JPSS Stored Mission Data Hub (JSH), as well as JPSS-1 and future JPSS-2 data. The SNPP SIPS will ingest EOS compatible Level 0 data from the EOS Data Operations System (EDOS) element for their data processing, enabling the continuous EOS-SNPP-JPSS Satellite Data Record.

  1. Sterile technique

    MedlinePlus

    ... the crook of your elbow. Getting Your Supplies Ready To open a sterile pad or kit: Wash your hands with soap and running water for at least 1 minute. Wash the backs, palms, fingers, and between ...

  2. Portable Chemical Sterilizer (PCS) for Surgical Instruments

    DTIC Science & Technology

    2004-12-01

    PORTABLE CHEMICAL STERILIZER (PCS) FOR SURGICAL INSTRUMENTS CJ Doona*, FE Feeherry, MA Curtin‡, K Kustin‡, S Kandlikar‡ U.S. Army-Soldier...denotes Contractors) Biomedical Technologies ABSTRACT A novel device called the Portable Chemical Sterilizer (PCS) has been developed for the...rapid, safe, portable, power-free, and convenient sterilization of objects or surfaces contaminated with pathogenic microorganisms that cause

  3. Sterilization effects of atmospheric cold plasma brush

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Q.S.; Huang, C.; Hsieh, F.-H.

    2006-01-02

    This study investigated the sterilization effects of a brush-shaped plasma created at one atmospheric pressure. A population of 1.0x10{sup 4}-1.0x10{sup 5} Escherichia coli or Micrococcus luteus bacteria was seeded in filter paper media and then subjected to Ar and/or Ar+O{sub 2} plasmas. A complete kill of the Micrococcus luteus required about 3 min argon plasma exposures. With oxygen addition into the argon plasma gas streams, a complete kill of the bacteria needed only less than 1 min plasma exposure for Micrococcus luteus and about 2 min exposure for Escherichia coli. The plasma treatment effects on the different bacteria cell structuresmore » were examined using scanning electron microscopy.« less

  4. Sterilization of Persons with Mental Retardation.

    ERIC Educational Resources Information Center

    Elkins, Thomas E.; Andersen, H. Frank

    1992-01-01

    This article examines the historical, legal, and ethical concerns regarding sterilization for persons with mental retardation and offers guidelines to help counsel individuals with disabilities or their families regarding decision making about sterilization. (DB)

  5. Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer.

    PubMed

    Rutala, W A; Gergen, M F; Weber, D J

    1999-07-01

    This study was undertaken to evaluate the efficacy of a new low-temperature sterilization system that recently has been cleared by the Food and Drug Administration, the Sterrad 50. Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were placed aseptically in the middle of 40-cm-long stainless steel-lumened test units of varying diameters (1 mm, 2 mm, and 3 mm). After inoculation, the test units were processed in the Sterrad 50. After sterilization, the carriers were assayed for growth of the B. stearothermophilus spores. Our data demonstrated that the Sterrad 50 was highly effective in killing the B. stearothermophilus spores (no positive carriers with 30 tests of each lumen-diameter test unit). The Sterrad 50 is likely to be clinically useful for the sterilization of heat-sensitive medical equipment.

  6. Leveraging community support for Education and Outreach: The IRIS E&O Program

    NASA Astrophysics Data System (ADS)

    Taber, J.; Hubenthal, M.; Wysession, M. E.

    2009-12-01

    The IRIS E&O Program was initiated 10 years ago, some 15 years after the creation of the IRIS Consortium, as IRIS members increasingly recognized the fundamental need to communicate the results of scientific research more effectively and to attract more students to study Earth science. Since then, IRIS E&O has received core funding through successive 5-year cooperative agreements with NSF, based on proposals submitted by IRIS. While a small fraction of the overall Consortium budget, this consistent funding has allowed the development of strong, long-term elements within the E&O Program, including summer internships, IRIS/USGS museum displays, seismographs in schools, IRIS/SSA Distinguished Lecture series, and professional development for middle school and high school teachers. Reliable funding has allowed us to develop expertise in these areas due to the longevity of the programs and the continuous improvement resulting from ongoing evaluations. Support from Consortium members, including volunteering time and expertise, has been critical for the program, as the Consortium has to continually balance the value of E&O products versus equipment and data services for seismology research. The E&O program also provides service to the Consortium, such as PIs being able to count on and leverage IRIS resources when defining the broader impacts of their own research. The reliable base has made it possible to build on the core elements with focused and innovative proposals, allowing, for example, the expansion of our internship program into a full REU site. Developing collaborative proposals with other groups has been a key strategy where IRIS E&O's long-term viability can be combined with expertise from other organizations to develop new products and services. IRIS can offer to continue to reliably deliver and maintain products after the end of a 2-3 year funding cycle, which can greatly increase the reach of the project. Consortium backing has also allowed us to establish an

  7. Differentiation of eosinophilic leukemia EoL-1 cells into eosinophils induced by histone deacetylase inhibitors.

    PubMed

    Ishihara, Kenji; Takahashi, Aki; Kaneko, Motoko; Sugeno, Hiroki; Hirasawa, Noriyasu; Hong, JangJa; Zee, OkPyo; Ohuchi, Kazuo

    2007-03-06

    EoL-1 cells differentiate into eosinophils in the presence of n-butyrate, but the mechanism has remained to be elucidated. Because n-butyrate can inhibit histone deacetylases, we hypothesized that the inhibition of histone deacetylases induces the differentiation of EoL-1 cells into eosinophils. In this study, using n-butyrate and two other histone deacetylase inhibitors, apicidin and trichostatin A, we have analyzed the relationship between the inhibition of histone deacetylases and the differentiation into eosinophils in EoL-1 cells. It was demonstrated that apicidin and n-butyrate induced a continuous acetylation of histones H4 and H3, inhibited the proliferation of EoL-1 cells without attenuating the level of FIP1L1-PDGFRA mRNA, and induced the expression of markers for mature eosinophils such as integrin beta7, CCR1, and CCR3 on EoL-1 cells, while trichostatin A evoked a transient acetylation of histones and induced no differentiation into eosinophils. These findings suggest that the continuous inhibition of histone deacetylases in EoL-1 cells induces the differentiation into mature eosinophils.

  8. It Security and EO Systems

    NASA Astrophysics Data System (ADS)

    Burnett, M.

    2010-12-01

    One topic that is beginning to influence the systems that support these goals is that of Information Technology (IT) Security. Unsecure systems are vulnerable to increasing attacks and other negative consequences; sponsoring agencies are correspondingly responding with more refined policies and more stringent security requirements. These affect how EO systems can meet the goals of data and service interoperability and harmonization through open access, transformation and visualization services. Contemporary systems, including the vision of a system-of-systems (such as GEOSS, the Global Earth Observation System of Systems), utilize technologies that support a distributed, global, net-centric environment. These types of systems have a high reliance on the open systems, web services, shared infrastructure and data standards. The broader IT industry has developed and used these technologies in their business and mission critical systems for many years. Unfortunately, the IT industry, and their customers have learned the importance of protecting their assets and resources (computing and information) as they have been forced to respond to an ever increasing number and more complex illegitimate “attackers”. This presentation will offer an overview of work done by the CEOS WGISS organization in summarizing security threats, the challenges to responding to them and capturing the current state of the practice within the EO community.

  9. Advanced E-O test capability for Army Next-Generation Automated Test System (NGATS)

    NASA Astrophysics Data System (ADS)

    Errea, S.; Grigor, J.; King, D. F.; Matis, G.; McHugh, S.; McKechnie, J.; Nehring, B.

    2015-05-01

    The Future E-O (FEO) program was established to develop a flexible, modular, automated test capability as part of the Next Generation Automatic Test System (NGATS) program to support the test and diagnostic needs of currently fielded U.S. Army electro-optical (E-O) devices, as well as being expandable to address the requirements of future Navy, Marine Corps and Air Force E-O systems. Santa Barbara infrared (SBIR) has designed, fabricated, and delivered three (3) prototype FEO for engineering and logistics evaluation prior to anticipated full-scale production beginning in 2016. In addition to presenting a detailed overview of the FEO system hardware design, features and testing capabilities, the integration of SBIR's EO-IR sensor and laser test software package, IRWindows 4™, into FEO to automate the test execution, data collection and analysis, archiving and reporting of results is also described.

  10. What We Have Learned with 16 Years of EO-1 Hyperion

    NASA Astrophysics Data System (ADS)

    Ungar, S.

    2016-12-01

    The Earth Observing-One (EO-1) satellite, launched in November of 2000, will complete its sixteenth and final year of operation at the end of calendar year 2016. Observations from the Hyperion Imaging Spectrometer on board EO-1 have contributed to hundreds of papers in refereed journals, conference proceeds and other presentations. The EO-1 Hyperion imaging spectrometer is the first and longest operating instrument that provides visible to shortwave infrared science-grade data from orbit. Hyperion has been used to study a variety of natural and anthropogenic phenomena including hazards and catastrophes, agricultural health and productivity, ecological disturbance/development, and land use/land cover change. As an example, Hyperion has been used in hazard and catastrophe studies to monitor and assess effects of tsunamis, earthquakes, volcanic eruptions, mudslides, tornadoes, hurricanes, wild-fires (natural and human ignited), oil spills, and the aftermath of world trade center bombing. This presentation summarizes the current status of EO-1 Hyperion in terms of key scientific findings to date and presents future plans for exploiting the upward of 90,000 scenes expected to be archived at USGS EROS by the end of the mission. Hyperion serves as the heritage orbital spectrometer for future global platforms, including the proposed NASA Hyperspectral Infrared Imager (HyspIRI) and the forthcoming German satellite, EnMAP. A key EO-1 mission goal was to evaluate the ability of satellite high spectral resolution imaging to characterize terrestrial surface state and processes at 30 m resolution. Researchers engaged in NASA's Terrestrial Ecology, Carbon Science, Land Use Change and other programs using the EO-1 Hyperion imaging spectrometer have achieved results with accuracies far exceeding those reached with the current spaceborne fleet of multispectral sensors. Hyperion data provide several advantages over data from multispectral satellite systems: they inherently provide

  11. End-of-life (EoL) mobile phone management in Hong Kong households.

    PubMed

    Deng, Wen-Jing; Giesy, John P; So, C S; Zheng, Hai-Long

    2017-09-15

    A questionnaire survey and interviews were conducted in households and end-of-life (EoL) mobile phone business centres in Hong Kong. Widespread Internet use, combined with the rapid evolution of modern social networks, has resulted in the more rapid obsolescence of mobile phones, and thus a tremendous increase in the number of obsolete phones. In 2013, the volume of EoL mobile phones generated in Hong Kong totalled at least 330 tonnes, and the amount is rising. Approximately 80% of electronic waste is exported to Africa and developing countries such as mainland China or Pakistan for recycling. However, the material flow of the large number of obsolete phones generated by the territory's households remains unclear. Hence, the flow of EoL mobile phones in those households was analysed, with the average lifespan of a mobile phone in Hong Kong found to be just under two years (nearly 23 months). Most EoL mobile phones are transferred to mainland China for disposal. Current recycling methods are neither environmentally friendly nor sustainable, with serious implications for the environment and human health. The results of this analysis provide useful information for planning the collection system and facilities needed in Hong Kong and mainland China to better manage EoL mobile phones in the future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. EPR STUDIES OF THERMALLY STERILIZED VASELINUM ALBUM.

    PubMed

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used for examination of free radicals in thermally treated vaselinum album (VA). Thermal treatment in hot air as sterilization process was tested. Conditions of thermal sterilization were chosen according to the pharmaceutical norms. Vaselinum album was heated at the following conditions (T--temperature, t--time): T = 160°C and t = 120 min, T = 170°C and t = 60 min and T = 180°C and t = 30 min. The aim of this work was to determine concentration and free radical properties of thermally sterilized VA. EPR analysis for VA was done 15 min after sterilization. EPR measurements were done at room temperature. EPR spectra were recorded in the range of microwave power of 2.2-70 mW. g-Factor, amplitudes (A) and line width (ΔBpp) of the spectra were determined. The shape of the EPR spectra was analyzed. Free radical concentration (N) in the heated samples was determined. EPR spectra were not obtained for the non heated VA. EPR spectra were detected for all thermally sterilized samples. The spectra revealed complex character, their asymmetry depends on microwave power. The lowest free radicals concentration was found for the VA sterilized at 180°C during 30 min. EPR spectroscopy is proposed as the method useful for optimization of sterilization process of drugs.

  13. [Determinants of sterilization among married couples in Korea].

    PubMed

    Kim, Ju Hee; Chung, Woojin; Lee, Sunmi; Suh, Moonhee; Kang, Dae Ryong

    2007-11-01

    The purpose of this study was to examine the determinants of sterilization in South Korea. This study was based on the data from the Korea National Fertility Survey carried out in the year 2000 by the Korea Institute of Health and Social Affairs. The subjects of the analysis were 4,604 women and their husbands who were in their first marriage, in the age group of 15-49 years. The data were analyzed by multiple logistic regression analysis. Consistent with the findings of previous studies, the woman's age and the number of total children increased the likelihood of sterilization. In addition, the year of marriage had a strong positive association with sterilization. Interestingly, the number of surviving sons tended to increase the likelihood of sterilization, whereas the woman's education level and age at the time of marriage showed a negative association with sterilization. Religion, place of residence, son preference, and the husband's education level, age and type of occupation were not significant determinants of sterilization. The sex of previous children and lower level of education are distinct determinants of sterilization among women in South Korea. More studies are needed in order to determine the associations between sterilization rate and decreased fertility.

  14. Sterilization of reusable implant components: a pilot study.

    PubMed

    Cain, J R; Mitchell, D L; Gillespie, J C

    2000-12-01

    The placement and restoration of dental implants require the use of numerous reusable instruments and components. The adequate sterilization of reusable instruments and components is essential to prevent cross contamination between patients. Sterilization usually is accomplished with single-use sterilization envelopes. A reusable sterilization vehicle would reduce costs as well as the waste generated in patient care. This study was designed to determine the efficacy of a 10-cc Pyrex test tube as a sterilization vehicle for reusable dental implant instruments and components. In this study, a reusable dental implant component was placed in a Pyrex test tube, along with a biologic test strip. A control biologic test strip was kept for each test tube. The test tube was closed with a cotton roll folded in half and placed in the opening. Twenty test tubes were prepared. five sets of 4 test tubes were placed in an autoclave in different locations with varying orientations. The autoclave completed a standard sterilization cycle. The biological monitoring service indicated that the biologic test strips in 100% of the test tubes were sterile, whereas the control strips were 100% nonsterile. A Pyrex test tube sealed with a cotton roll can serve as a sterilization vehicle for reusable dental implant instruments and components.

  15. Sterilization techniques for biodegradable scaffolds in tissue engineering applications

    PubMed Central

    Dai, Zheng; Ronholm, Jennifer; Tian, Yiping; Sethi, Benu; Cao, Xudong

    2016-01-01

    Biodegradable scaffolds have been extensively studied due to their wide applications in biomaterials and tissue engineering. However, infections associated with in vivo use of these scaffolds by different microbiological contaminants remain to be a significant challenge. This review focuses on different sterilization techniques including heat, chemical, irradiation, and other novel sterilization techniques for various biodegradable scaffolds. Comparisons of these techniques, including their sterilization mechanisms, post-sterilization effects, and sterilization efficiencies, are discussed. PMID:27247758

  16. Selection of biological indicator for validating microwave heating sterilization.

    PubMed

    Sasaki, K; Mori, Y; Honda, W; Miyake, Y

    1998-01-01

    For the purpose of selecting an appropriate biological indicator for evaluation of the effects of microwave heating sterilization, we examined aerobic bacterial spores to determine whether microwaves have non-thermal sterilization effects. After microwave irradiation on dry bacterial spores (three species), none of the bacterial spores were killed. The survival rate of the spores after microwave irradiation of spore suspensions (twelve species) was compared with that after heating by a conventional method. The order of heat resistance in the bacterial species was similar between the two heating methods. Bacillus stearothermophilus spores were the most heat-resistant. These results suggest that microwaves have no non-thermal sterilization effects on bacterial spores, the specific resistant spores to microwave heating, and microwave heating sterilization can be evaluated in the same way as for conventional heating sterilization. As a biological indicator for evaluation of overkill sterilization, B. stearothermophilus spores may be appropriate for microwave heating sterilization as well as steam sterilization.

  17. Reducing the radiation sterilization dose improves mechanical and biological quality while retaining sterility assurance levels of bone allografts.

    PubMed

    Nguyen, Huynh; Cassady, Alan I; Bennett, Michael B; Gineyts, Evelyne; Wu, Andy; Morgan, David A F; Forwood, Mark R

    2013-11-01

    Bone allografts carry a risk of infection, so terminal sterilization by gamma irradiation at 25kGy is recommended; but is deleterious to bone quality. Contemporary bone banking significantly reduces initial allograft bioburden, questioning the need to sterilize at 25kGy. We inoculated allograft bone with Staphylococcus epidermidis and Bacillus pumilus, then exposed them to gamma irradiation at 0, 5, 10, 15, 20 and 25kGy. Mechanical and biological properties of allografts were also assessed. Our aim was to determine an optimal dose that achieves sterility assurance while minimizing deleterious effects on allograft tissue. 20-25kGy eliminated both organisms at concentrations from 10(1) to 10(3)CFU, while 10-15kGy sterilized bone samples to a bioburden concentration of 10(2)CFU. Irradiation did not generate pro-inflammatory bone surfaces, as evidenced by macrophage activation, nor did it affect attachment or proliferation of osteoblasts. At doses ≥10kGy, the toughness of cortical bone was reduced (P<0.05), and attachment and fusion of osteoclasts onto irradiated bone declined at 20 and 25kGy (P<0.05). There was no change in collagen cross-links, but a significant dose-response increase in denatured collagen (P<0.05). Our mechanical and cell biological data converge on 15kGy as a threshold for radiation sterilization of bone allografts. Between 5 and 15kGy, bone banks can undertake validation that provides allografts with an acceptable sterility assurance level, improving their strength and biocompatibility significantly. The application of radiation sterilization doses between 5 and 15kGy will improve bone allograft mechanical performance and promote integration, while retaining sterility assurance levels. Improved quality of allograft bone will promote superior clinical outcomes. © 2013.

  18. A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology

    PubMed Central

    Abrisham, Seyed Mohammad J.; Bouzarjomehri, Fathollah; Nafisi-Moghadam, Reza; Sobhan, Mohammad R.; Gadimi, Mahdie; Omidvar, Fereshte

    2017-01-01

    Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and precision of the system was confirmed according to the acceptance testing. The same procedure was used for 18 patients referred for lumbar spine digital radiology (overall 36 images). Results: Although radiation fields in the EOS were almost twice of that in digital radiology, and the average peak tube voltage (kVp), current supply to the tube (mA), and the average size and age of the patients referred for EOS imaging were greater than digital radiology, however, the average DAP in EOS was 1/5 of that in digital radiology system. Also, the average dose in the EOS was about 1/20 of that in digital radiology. Conclusion: The patient dose in EOS imaging system was lower in comparison with digital radiology (1/20). PMID:28656161

  19. A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology.

    PubMed

    Abrisham, Seyed Mohammad J; Bouzarjomehri, Fathollah; Nafisi-Moghadam, Reza; Sobhan, Mohammad R; Gadimi, Mahdie; Omidvar, Fereshte

    2017-05-01

    This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and precision of the system was confirmed according to the acceptance testing. The same procedure was used for 18 patients referred for lumbar spine digital radiology (overall 36 images). Although radiation fields in the EOS were almost twice of that in digital radiology, and the average peak tube voltage (kV p ), current supply to the tube (mA), and the average size and age of the patients referred for EOS imaging were greater than digital radiology, however, the average DAP in EOS was 1/5 of that in digital radiology system. Also, the average dose in the EOS was about 1/20 of that in digital radiology. The patient dose in EOS imaging system was lower in comparison with digital radiology (1/20).

  20. A novel steam explosion sterilization improving solid-state fermentation performance.

    PubMed

    Zhao, Zhi-Min; Wang, Lan; Chen, Hong-Zhang

    2015-09-01

    Traditional sterilization of solid medium (SM) requires lengthy time, degrades nutrients, and even sterilizes inadequately compared with that of liquid medium due to its low thermal conductivity. A novel sterilization strategy, high-temperature and short-time steam explosion (SE), was exploited for SM sterilization in this study. Results showed that SE conditions for complete sterilization were 172 °C for 2 min and 128 °C for 5 min. Glucose and xylose contents in medium after SE sterilization increased by 157% and 93% respectively compared with those after conventional sterilization (121 °C, 20 min) while fermentation inhibitors were not detected. FTIR spectra revealed that the mild SE conditions helped to release monosaccharides from the polysaccharides. Bacillus subtilis fermentation productivity on medium after SE sterilization was 3.83 times of that after conventional sterilization. Therefore, SE shortened sterilization time and improved SM nutrition, which facilitated fermentability of SM and should promote economy of solid-state fermentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Postpartum Sterilization

    MedlinePlus

    ... a few hours or days following delivery. For women who have had a cesarean delivery, it is done right after the baby is born. How is postpartum sterilization performed? For women who have had a vaginal delivery, a small ...

  2. Earth observing system. Data and information system. Volume 2A: Report of the EOS Data Panel

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The purpose of this report is to provide NASA with a rationale and recommendations for planning, implementing, and operating an Earth Observing System data and information system that can evolve to meet the Earth Observing System's needs in the 1990s. The Earth Observing System (Eos), defined by the Eos Science and Mission Requirements Working Group, consists of a suite of instruments in low Earth orbit acquiring measurements of the Earth's atmosphere, surface, and interior; an information system to support scientific research; and a vigorous program of scientific research, stressing study of global-scale processes that shape and influence the Earth as a system. The Eos data and information system is conceived as a complete research information system that would transcend the traditional mission data system, and include additional capabilties such as maintaining long-term, time-series data bases and providing access by Eos researchers to relevant non-Eos data. The Working Group recommends that the Eos data and information system be initiated now, with existing data, and that the system evolve into one that can meet the intensive research and data needs that will exist when Eos spacecraft are returning data in the 1990s.

  3. Radiation sterilization of aseptically manufactured products.

    PubMed

    Fairand, Barry P; Fidopiastis, Niki

    2010-01-01

    This paper discusses an approach for establishing a sterilization dose for an aseptically processed product after the product is in its final packaged state, in other words, terminal sterilization. It applies to aseptic processes where the fill/finish operation is conducted in a closed system using isolator or restricted access barrier technology, that is, no human intervention. The example that is given in this paper uses gamma radiation as the sterilizing agent. Other forms of radiation such as high-energy electrons or X-rays also could serve as the sterilizing agent. The proposed approach involves irradiation of the aseptically processed product at very low doses of radiation, which is possible due to the extremely low levels of bioburden that may be present on the product following a fill/finish operation. Rather than sacrificing a large number of product units that may be required to obtain a statistically significant sampling of the product for bioburden analysis and other test purposes, the test unit is a surrogate consisting of actual pharmaceutical product that was inoculated with a highly radiation-resistant micro-organism. Selection of the microorganism was based on analysis of a library of environmental monitoring data taken from the aseptic area. Because of microbial diversity between different aseptic processing facilities, selection of the test microorganism would depend on the aseptic area under study. The approach that is discussed in this paper addresses selection and preparation of the surrogate, test of sterility of the surrogate following irradiation, determination of the radiation resistance of the test microorganism, and application of the approach to calculate a sterilization dose that is less than 10 kGy. At this low dose, it may be possible to terminally sterilize radiation-sensitive pharmaceutical products, for example, those in liquid form. Additional studies are warranted to determine the general applicability of the proposed approach.

  4. Health technology assessment: Off-site sterilization

    PubMed Central

    Dehnavieh, Reza; Mirshekari, Nadia; Ghasemi, Sara; Goudarzi, Reza; Haghdoost, AliAkbar; Mehrolhassani, Mohammad Hossain; Moshkani, Zahra; Noori Hekmat, Somayeh

    2016-01-01

    Background: Every year millions of dollars are expended to equip and maintain the hospital sterilization centers, and our country is not an exception of this matter. According to this, it is important to use more effective technologies and methods in health system in order to reach more effectiveness and saving in costs. This study was conducted with the aim of evaluating the technology of regional sterilization centers. Methods: This study was done in four steps. At the first step, safety and effectiveness of technology was studied via systematic study of evidence. The next step was done to evaluate the economical aspect of off-site sterilization technology using gathered data from systematic review of the texts which were related to the technology and costs of off-site and in-site hospital sterilization. Third step was conducted to collect experiences of using technology in some selected hospitals around the world. And in the last step different aspects of acceptance and use of this technology in Iran were evaluated. Results: Review of the selected articles indicated that efficacy and effectiveness of this technology is Confirmed. The results also showed that using this method is not economical in Iran. Conclusion: According to the revealed evidences and also cost analysis, due to shortage of necessary substructures and economical aspect, installing the off-site sterilization health technology in hospitals is not possible currently. But this method can be used to provide sterilization services for clinics and outpatients centers. PMID:27390714

  5. Plans for the development of EOS SAR systems using the Alaska SAR facility. [Earth Observing System (EOS)

    NASA Technical Reports Server (NTRS)

    Carsey, F. D.; Weeks, W.

    1988-01-01

    The Alaska SAR Facility (ASF) program for the acquisition and processing of data from the ESA ERS-1, the NASDA ERS-1, and Radarsat and to carry out a program of science investigations using the data is introduced. Agreements for data acquisition and analysis are in place except for the agreement between NASA and Radarsat which is in negotiation. The ASF baseline system, consisting of the Receiving Ground System, the SAR Processor System and the Archive and Operations System, passed critical design review and is fully in implementation phase. Augments to the baseline system for systems to perform geophysical processing and for processing of J-ERS-1 optical data are in the design and implementation phase. The ASF provides a very effective vehicle with which to prepare for the Earth Observing System (EOS) in that it will aid the development of systems and technologies for handling the data volumes produced by the systems of the next decades, and it will also supply some of the data types that will be produced by EOS.

  6. Auditing radiation sterilization facilities

    NASA Astrophysics Data System (ADS)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  7. EO-1 analysis applicable to coastal characterization

    NASA Astrophysics Data System (ADS)

    Burke, Hsiao-hua K.; Misra, Bijoy; Hsu, Su May; Griffin, Michael K.; Upham, Carolyn; Farrar, Kris

    2003-09-01

    The EO-1 satellite is part of NASA's New Millennium Program (NMP). It consists of three imaging sensors: the multi-spectral Advanced Land Imager (ALI), Hyperion and Atmospheric Corrector. Hyperion provides a high-resolution hyperspectral imager capable of resolving 220 spectral bands (from 0.4 to 2.5 micron) with a 30 m resolution. The instrument images a 7.5 km by 100 km land area per image. Hyperion is currently the only space-borne HSI data source since the launch of EO-1 in late 2000. The discussion begins with the unique capability of hyperspectral sensing to coastal characterization: (1) most ocean feature algorithms are semi-empirical retrievals and HSI has all spectral bands to provide legacy with previous sensors and to explore new information, (2) coastal features are more complex than those of deep ocean that coupled effects are best resolved with HSI, and (3) with contiguous spectral coverage, atmospheric compensation can be done with more accuracy and confidence, especially since atmospheric aerosol effects are the most pronounced in the visible region where coastal feature lie. EO-1 data from Chesapeake Bay from 19 February 2002 are analyzed. In this presentation, it is first illustrated that hyperspectral data inherently provide more information for feature extraction than multispectral data despite Hyperion has lower SNR than ALI. Chlorophyll retrievals are also shown. The results compare favorably with data from other sources. The analysis illustrates the potential value of Hyperion (and HSI in general) data to coastal characterization. Future measurement requirements (air borne and space borne) are also discussed.

  8. CLONAL INHERITANCE OF A DIPLOID NUCLEAR GENOME BY A HYBRID FRESHWATER MINNOW (PHOXINUS EOS-NEOGAEUS, PISCES: CYPRINIDAE).

    PubMed

    Goddard, Kathryn Ann; Dawley, Robert M

    1990-07-01

    Hybrids between the minnows Phoxinus eos and Phoxinus neogaeus coexist with a population of P. eos in East Inlet Pond, Coos Co., New Hampshire. Chromosome counts and flow cytometric analysis of erythrocyte DNA indicate that these hybrids include diploids, triploids, and diploid-triploid mosaics. The mosaics have both diploid and triploid cells in their bodies, even within the same tissues. All three hybrid types are heterozygous at seven putative loci for which P. eos and P. neogaeus are fixed for different allozymes, indicating that the hybrids carry one eos and one neogaeus haploid genome. The diploid hybrids are therefore P. eos-neogaeus, whereas the triploids and mosaics are derived from P. eos-neogaeus but have an extra eos or neogaeus genome in all or some of their cells. Diploid, triploid, and mosaic hybrids accept tissue grafts from diploid hybrids, indicating that all individuals carry the identical eos-neogaeus diploid genome. Thus, one P. eos-neogaeus clone exists at East Inlet Pond. Grafts among the triploids and mosaics or from these individuals to diploid hybrids are rejected, indicating that the third genome is different in each triploid and mosaic individual. In this study, diploid and mosaic hybrids, carrying the clonal eos-neogaeus genome, were bred in the laboratory with males of P. eos or P. neogaeus. Both diploid and mosaic hybrids produced diploid, triploid, and mosaic offspring, revealing the source of the three hybrid types present at East Inlet Pond. These offspring accepted grafts from P. eos-neogaeus individuals, indicating that they all had inherited the identical eos-neogaeus genome. Most grafts among triploid and mosaic progeny, or from these individuals to their diploid broodmates, were rejected, indicating that the third genome was different in each triploid and mosaic (as was observed in the wild hybrids) and was contributed by sperm from males of P. eos or P. neogaeus. Diploid progeny are produced if sperm serves only to stimulate

  9. [Contraceptive choices and experience of sexuality: a comparison between sterilized and non-sterilized women in a metropolitan area of southeastern Brazil].

    PubMed

    Villela, W; Barbosa, R

    1996-10-01

    A cross sectional study involving 357 women, 174 of them sterilized and 183 non-sterilized, with a view to comparing their sexual and reproductive behaviour, was undertaken. The questionnaire was based on previous focus group discussions with both women and men, to find out the best way to approach related questions. The results show that sterilized women-who are older and more often have steady partnerships than non-sterilized women-fulfil traditional gender roles more closely than the others. Furthermore, no sterilized woman had used the condom in the month prior to the interview. It is suggested that public messages for the prevention of the spread of the HIV, sexually-transmissible disease and cervical cancer should target women who have been sterilized for the purpose of increasing the use of the condom in accordance with specific strategies.

  10. Solution-Based Electro-Orientation Spectroscopy (EOS) for Contactless Measurement of Semiconductor Nanowires

    NASA Astrophysics Data System (ADS)

    Yuan, Wuhan; Mohabir, Amar; Tutuncuoglu, Gozde; Filler, Michael; Feldman, Leonard; Shan, Jerry

    2017-11-01

    Solution-based, contactless methods for determining the electrical conductivity of nanowires and nanotubes have unique advantages over conventional techniques in terms of high throughput and compatibility with further solution-based processing and assembly methods. Here, we describe the solution-based electro-orientation spectroscopy (EOS) method, in which nanowire conductivity is measured from the AC-electric-field-induced alignment rate of the nanowire in a suspending fluid. The particle conductivity is determined from the measured crossover frequency between conductivity-dominated, low-frequency alignment to the permittivity-dominated, high-frequency regime. We discuss the extension of the EOS measurement range by an order-of-magnitude, taking advantage of the high dielectric constant of deionized water. With water and other fluids, we demonstrate that EOS can quantitatively characterize the electrical conductivities of nanowires over a 7-order-of-magnitude range, 10-5 to 102 S/m. We highlight the efficiency and utility of EOS for nanomaterial characterization by statistically characterizing the variability of semiconductor nanowires of the same nominal composition, and studying the connection between synthesis parameters and properties. NSF CBET-1604931.

  11. Effects of sterilization on poly(ethylene glycol) hydrogels.

    PubMed

    Kanjickal, Deenu; Lopina, Stephanie; Evancho-Chapman, M Michelle; Schmidt, Steven; Donovan, Duane

    2008-12-01

    The past few decades have witnessed a dramatic increase in the development of polymeric biomaterials. These biomaterials have to undergo a sterilization procedure before implantation. However, many sterilization procedures have been shown to profoundly affect polymer properties. Poly(ethylene glycol) hydrogels have gained increasing importance in the controlled delivery of therapeutics and in tissue engineering. We evaluated the effect of ethylene oxide (EtO), hydrogen peroxide (H(2)O(2)), and gamma sterilization of poly(ethylene glycol) hydrogels on properties relevant to controlled drug delivery and tissue engineering. We observed that the release of cyclosporine (CyA) (an immunosuppressive drug that is effective in combating tissue rejection following organ transplantation) was significantly affected by the type of sterilization. However, that was not the case with rhodamine B, a dye. Hence, the drug release characteristics were observed to be dependent not only on the sterilization procedure but also on the type of agent that needs to be delivered. In addition, differences in the swelling ratios for the sterilized and unsterilized hydrogels were statistically significant for 1:1 crosslinked hydrogels derived from the 8000 MW polymer. Significant differences were also observed for gamma sterilization for 1:1 crosslinked hydrogels derived from the 3350 MW polymer and also the 2:1 crosslinked hydrogels derived from the 8000 MW polymer. Atomic force microscopy (AFM) studies revealed that the roughness parameter for the unsterilized and EtO-sterilized PEG hydrogels remained similar. However, a statistically significant reduction of the roughness parameter was observed for the H(2)O(2) and gamma-sterilized samples. Electron spin resonance (ESR) studies on the unsterilized and the sterilized samples revealed the presence of the peroxy and the triphenyl methyl carbon radical in the samples. The gamma and the H(2)O(2)-sterilized samples were observed to have a much

  12. Regret, shame, and denials of women's voluntary sterilization.

    PubMed

    Lalonde, Dianne

    2018-06-01

    Women face extraordinary difficulty in seeking sterilization as physicians routinely deny them the procedure. Physicians defend such denials by citing the possibility of future regret, a well-studied phenomenon in women's sterilization literature. Regret is, however, a problematic emotion upon which to deny reproductive freedom as regret is neither satisfactorily defined and measured, nor is it centered in analogous cases regarding men's decision to undergo sterilization or the decision of women to undergo fertility treatment. Why then is regret such a concern in the voluntary sterilization of women? I argue that regret is centered in women's voluntary sterilization due to pronatalism or expectations that womanhood means motherhood. Women seeking voluntary sterilization are regarded as a deviant identity that rejects what is taken to be their essential role of motherhood and they are thus seen as vulnerable to regret. © 2018 John Wiley & Sons Ltd.

  13. Spin states of asteroids in the Eos collisional family

    NASA Astrophysics Data System (ADS)

    Hanuš, J.; Delbo', M.; Alí-Lagoa, V.; Bolin, B.; Jedicke, R.; Ďurech, J.; Cibulková, H.; Pravec, P.; Kušnirák, P.; Behrend, R.; Marchis, F.; Antonini, P.; Arnold, L.; Audejean, M.; Bachschmidt, M.; Bernasconi, L.; Brunetto, L.; Casulli, S.; Dymock, R.; Esseiva, N.; Esteban, M.; Gerteis, O.; de Groot, H.; Gully, H.; Hamanowa, Hiroko; Hamanowa, Hiromi; Krafft, P.; Lehký, M.; Manzini, F.; Michelet, J.; Morelle, E.; Oey, J.; Pilcher, F.; Reignier, F.; Roy, R.; Salom, P. A.; Warner, B. D.

    2018-01-01

    Eos family was created during a catastrophic impact about 1.3 Gyr ago. Rotation states of individual family members contain information about the history of the whole population. We aim to increase the number of asteroid shape models and rotation states within the Eos collision family, as well as to revise previously published shape models from the literature. Such results can be used to constrain theoretical collisional and evolution models of the family, or to estimate other physical parameters by a thermophysical modeling of the thermal infrared data. We use all available disk-integrated optical data (i.e., classical dense-in-time photometry obtained from public databases and through a large collaboration network as well as sparse-in-time individual measurements from a few sky surveys) as input for the convex inversion method, and derive 3D shape models of asteroids together with their rotation periods and orientations of rotation axes. We present updated shape models for 15 asteroids and new shape model determinations for 16 asteroids. Together with the already published models from the publicly available DAMIT database, we compiled a sample of 56 Eos family members with known shape models that we used in our analysis of physical properties within the family. Rotation states of asteroids smaller than ∼ 20 km are heavily influenced by the YORP effect, whilst the large objects more or less retained their rotation state properties since the family creation. Moreover, we also present a shape model and bulk density of asteroid (423) Diotima, an interloper in the Eos family, based on the disk-resolved data obtained by the Near InfraRed Camera (Nirc2) mounted on the W.M. Keck II telescope.

  14. An Evaluation of β-Propiolactone for the Sterilization of Fermentation Media1

    PubMed Central

    Himmelfarb, Philip; Read, R. B.; Litsky, Warren

    1961-01-01

    Twenty-five bacterial species were cultured in basal broth plus 1 of 19 different carbohydrates which were sterilized by Seitz filtration, autoclaving (112 C, 10 min), or exposure to 0.2% β-propiolactone (BPL). No significant differences were found either in the visual observations for acid and gas, pH, or titrable acidity determinations after 3 days of incubation with any of the three preparations tested. An effort was made to further determine the effect of BPL and heat on carbohydrates by assaying for glucose before and after treatment. Results indicated that glucose was not degraded by 0.2% BPL, however, it was shown that autoclave temperatures caused extensive degradation. Statistical treatment of the results from Warburg studies indicated that BPL-treated glucose showed no appreciable toxic effects, although the actual oxygen uptake was not as great as with Seitz- or autoclave-treated glucose. The application of the BPL sterilization process was discussed. PMID:13907502

  15. [Peracetic acid: alternative to the sterilization of bronchofibroscopes].

    PubMed

    Villate, J I; Barrón, J; Zalacaín, R; Urcelay, M I; Hernández, J M; Argumedo, M

    1997-03-01

    The Steris system for cold sterilization with peracetic acid was evaluated by effecting a series of contaminations of a fiberoptic bronchoscope (FB) with specimens of Pseudomonas aeruginosa, Acinetobacter baumanii and Mycobacterium kansasi. The FB was contaminated 24 times, 8 times by each microorganism, using specimens containing more than 10(8) cfu/ml. After fixing the secretions on the FB and washing it with enzyme soap, the BF was sterilized. Specimens were taken for culturing after contamination of the FB, after washing, immediately after sterilization and 1 hour after sterilization. No microorganism growth of any of the samples was detected either immediately after sterilization or one hour later. Microbiological data confirmed contamination of the FB after aspiration and fixation of the inoculate. Chemical and biological tests with B. stearothermophilus spores as specified by the manufacturer were correct in all cases: 24 contaminations and 52 processes of prior training. The efficacy of washing with enzyme soap before sterilization stands out. In 14 of the 24 samples, culture was negative after washing and in 7 the concentration of microorganisms was less than 500 cfu/ml, which confirms the need for appropriate washing before any disinfection or sterilization process is begun. In conclusion, the Steris system based on peracetic acid is an alternative to other systems for cold sterilization or high level disinfection.

  16. Efficacy of chemically characterized Foeniculum vulgare Mill seed essential oil in protection of raw tobacco leaves during storage against fungal and aflatoxin contamination.

    PubMed

    Kedia, A; Dwivedy, A K; Pandey, A K; Kumar, R R; Regmi, P; Dubey, N K

    2015-10-01

    To report fungal and aflatoxin contamination in stored tobacco leaves and the potential of Foeniculum vulgare (fennel) seed essential oil (EO) as a plant-based preservative in protection of tobacco during storage. Mycological analysis of tobacco samples was done by surface sterilization and serial dilution tests. The Aspergillus flavus isolates were screened for their toxigenicity. Both in vivo and in vitro tests were done to evaluate antifungal and antiaflatoxigenic efficacy of chemically characterized EO. The mycoflora analysis revealed 108 fungal colonies belonging to five genera and nine species. All A. flavus isolates were found aflatoxigenic during screening. Gas chromatography and mass spectrometry analysis of EO identified 19 components (99·66%); estragole being the major component (47·49%). The EO showed broad fungitoxicity at 1·25 μl ml(-1) and 100% inhibition to AFB1 production as well as ergosterol synthesis at 1·0 μl ml(-1) concentration. EO showed 100% protection of stored tobacco samples from aflatoxin B1 contamination. The fennel EO can thus be formulated as a plant-based preservative for food items. The present investigation comprises the first report on antiaflatoxin efficacy of fennel oil and its potency in the protection of tobacco leaves from fungal and aflatoxin contamination during storage. © 2015 The Society for Applied Microbiology.

  17. Communicating Earth Observation (EO)-based landslide mapping capabilities to practitioners

    NASA Astrophysics Data System (ADS)

    Albrecht, Florian; Hölbling, Daniel; Eisank, Clemens; Weinke, Elisabeth; Vecchiotti, Filippo; Kociu, Arben

    2016-04-01

    Current remote sensing methods and the available Earth Observation (EO) data for landslide mapping already can support practitioners in their processes for gathering and for using landslide information. Information derived from EO data can support emergency services and authorities in rapid mapping after landslide-triggering events, in landslide monitoring and can serve as a relevant basis for hazard and risk mapping. These applications also concern owners, maintainers and insurers of infrastructure. Most often practitioners have a rough overview of the potential and limits of EO-based methods for landslide mapping. However, semi-automated image analysis techniques are still rarely used in practice. This limits the opportunity for user feedback, which would contribute to improve the methods for delivering fully adequate results in terms of accuracy, applicability and reliability. Moreover, practitioners miss information on the best way of integrating the methods in their daily processes. Practitioners require easy-to-grasp interfaces for testing new methods, which in turn would provide researchers with valuable user feedback. We introduce ongoing work towards an innovative web service which will allow for fast and efficient provision of EO-based landslide information products and that supports online processing. We investigate the applicability of various very high resolution (VHR), e.g. WorldView-2/3, Pleiades, and high resolution (HR), e.g. Landsat, Sentinel-2, optical EO data for semi-automated mapping based on object-based image analysis (OBIA). The methods, i.e. knowledge-based and statistical OBIA routines, are evaluated regarding their suitability for inclusion in a web service that is easy to use with the least amount of necessary training. The pre-operational web service will be implemented for selected study areas in the Alps (Austria, Italy), where weather-induced landslides have happened in the past. We will test the service on its usability together

  18. Failure of non-vacuum steam sterilization processes for dental handpieces.

    PubMed

    Winter, S; Smith, A; Lappin, D; McDonagh, G; Kirk, B

    2017-12-01

    Dental handpieces are used in critical and semi-critical operative interventions. Although some dental professional bodies recommend that dental handpieces are sterilized between patient use there is a lack of clarity and understanding of the effectiveness of different steam sterilization processes. The internal mechanisms of dental handpieces contain narrow lumens (0.8-2.3 mm) which can impede the removal of air and ingress of saturated steam required to achieve sterilization conditions. To identify the extent of sterilization failure in dental handpieces using a non-vacuum process. In-vitro and in-vivo investigations were conducted on widely used UK bench-top steam sterilizers and three different types of dental handpieces. The sterilization process was monitored inside the lumens of dental handpieces using thermometric (TM; dataloggers), chemical indicator (CI), and biological indicator (BI) methods. All three methods of assessing achievement of sterility within dental handpieces that had been exposed to non-vacuum sterilization conditions demonstrated a significant number of failures [CI: 8/3024 (fails/no. of tests); BI: 15/3024; TM: 56/56] compared to vacuum sterilization conditions (CI: 2/1944; BI: 0/1944; TM: 0/36). The dental handpiece most likely to fail sterilization in the non-vacuum process was the surgical handpiece. Non-vacuum sterilizers located in general dental practice had a higher rate of sterilization failure (CI: 25/1620; BI: 32/1620; TM: 56/56) with no failures in vacuum process. Non-vacuum downward/gravity displacement, type N steam sterilizers are an unreliable method for sterilization of dental handpieces in general dental practice. The handpiece most likely to fail sterilization is the type most frequently used for surgical interventions. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. [Preliminary Study of Lonicera hypoglauca on Germination Conditions of Sand Culture Seeds and Sterilization Method of Sand Culture Seedling Sterilization].

    PubMed

    Tan, Mu-xiu; Zeng, Wen-wen; Wei, Peng-xiao; Mo, Qiao-cheng; Pu, Zu-ning; Cen, Xiu-fen; Shi, Feng-hua

    2015-05-01

    To explore the germination conditions of Lonicera hypoglauca sand culture seeds and the effects of sand culture seedlings sterilization. 0.1% HgCl2 with different sterilization time, different illumination time and temperature culture condition were adopted to study the germination conditions of sand culture seeds. Different sterilization treatments and different hardening-seedling days were used to test the sterilization effect of sand culture seedlings. The sterilization effect of the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min on Lonicera hypoglauca seeds was the optimum,with the average pollution rate of 15.56%, and the average germination rate reached 51.11%. The combination of varied temperature-room temperature under light for 12 h/d was the best, with the average germination rate peaked at 75.49%, and the average germination potential reached 68.36%. The treatment of detergent liquor scrub-tap water wash on the part above the hypocotyl, which was sand cultured under the opening condition and had no root, showed the best sterilization effect, with the average pollution rate was zero, and the average survival rate peaked at 100.00%. The sterilization effect of sand culture seedlings, which was disinfected after cleaning by detergent liquor scrub-tap water wash after hardening-seeding for 30 days, was the best, with the average pollution rate of 50.00%, and the average survival rate of 100.00%. The best sterilization effect is the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min; Lighting for 12 h/d of varied temperature-room temperature is regarded as the optimum culture condition. The treatment of detergent liquor scrub-tap water wash treatment on the part above the hypocotyl,which is sand cultured under the opening condition and had no root, shows the best sterilization effect. For the sand culture seedlings, before inoculated in subculture medium, should be hardening-seedling for some days and sterilized after detergent liquor scrub-tap water wash.

  20. Earth Observatory Satellite system definition study. Report no. 7: EOS system definition report

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The design concept and operational aspects of the Earth Observatory Satellite (EOS) are presented. A table of the planned EOS missions is included to show the purpose of the mission, the instruments involved, and the launch date. The subjects considered in the analysis of the EOS development are: (1) system requirements, (2) design/cost trade methodology, (3) observatory design alternatives, (4) the data management system, (5) the design evaluation and preferred approach, (6) program cost compilation, (7) follow-on mission accommodation, and (8) space shuttle interfaces and utilization. Illustrations and block diagrams of the spacecraft configurations are provided.

  1. Western Eos Chaos on Mars: A Potential Site for Future Landing and Returning Samples

    NASA Astrophysics Data System (ADS)

    Asif Iqbal Kakkassery; Rajesh, V. J.

    2018-04-01

    Introducing Eos Chaos as a potential area for collecting samples. Eos Chaos contains a number of aqueous minerals. We have detected zoisite — a least reported low-grade metamorphic mineral from this area.

  2. Ozone--the latest advance in sterilization of medical devices.

    PubMed

    Murphy, Lorna

    2006-06-01

    How many times have procedures in your operating rooms been delayed because the instruments needed were still in the sterilizer? As Perioperative nurses you are likely to be quite familiar with the constant pressure to ensure that scarce instrumentation is available when needed. In 2003, a Canadian company developed a unique sterilization process employing ozone as the sterilizing agent. This technology is a safe, rapid and economical alternative to other low temperature sterilization modalities and may relieve some of the pressure experienced when instruments in short supply are in high demand. This article will discuss the principles of the sterilizer and the cycle and will explore the advantages of using this sterilization technology.

  3. Towards simulating and quantifying the light-cone EoR 21-cm signal

    NASA Astrophysics Data System (ADS)

    Mondal, Rajesh; Bharadwaj, Somnath; Datta, Kanan K.

    2018-02-01

    The light-cone (LC) effect causes the Epoch of Reionization (EoR) 21-cm signal T_b (\\hat{n}, ν ) to evolve significantly along the line-of-sight (LoS) direction ν. In the first part of this paper, we present a method to properly incorporate the LC effect in simulations of the EoR 21-cm signal that includes peculiar velocities. Subsequently, we discuss how to quantify the second-order statistics of the EoR 21-cm signal in the presence of the LC effect. We demonstrate that the 3D power spectrum P(k) fails to quantify the entire information because it assumes the signal to be ergodic and periodic, whereas the LC effect breaks these conditions along the LoS. Considering a LC simulation centred at redshift 8 where the mean neutral fraction drops from 0.65 to 0.35 across the box, we find that P(k) misses out ˜ 40 per cent of the information at the two ends of the 17.41 MHz simulation bandwidth. The multifrequency angular power spectrum (MAPS) C_{ℓ}(ν_1,ν_2) quantifies the statistical properties of T_b (\\hat{n}, ν ) without assuming the signal to be ergodic and periodic along the LoS. We expect this to quantify the entire statistical information of the EoR 21-cm signal. We apply MAPS to our LC simulation and present preliminary results for the EoR 21-cm signal.

  4. [Is female sterilization voluntary in El Salvador]?].

    PubMed

    Bertrand, J T; Landry, E G; Araya Zelaya, J D

    1986-01-01

    Sexual sterilization has become an increasingly important family planning method in developing countries, and notably so in Latin America, but some controversy has surrounded the practice because of the suggestion that individuals are coerced into undergoing sterilization. With the goal of examining allegations that low-income women in El Salvador are sterilized without their full knowledge or consent in family planning programs financed by the US, researchers interviewed 648 women who had received the operation in one of 7 facilities in El Salvador. In general, women were interviewed 1 month after their operation, by 6 trained female interviewers, with the assurance that the follow-up effort was not in any way connected with the facility performing the operation. An effort to sample approximately the same number of women from each facility was not entirely successful because of access difficulties. Most interviewees had been sterilized at below 30 years of age (average age at sterilization was 28 years), had begun having children in adolescence, and had not received more than a primary education. They had an average of 3.4 children and 1/3 had experienced the death of at least 1 child. The response to the survey indicated that female sterilization in El Salvador is voluntary. Women were shown to be aware of other contraception options. They had found out about sterilization and had become further informed about the method through providers and through communications with other women who had known about the operation at least 3 years before making a decision to submit to it, and many had waited between 1 month and 1 year before/between the decision and the actual operation. Only 1 women claimed to have felt pressured to be sterilized, identifying her mother as the source of the pressure.

  5. New insights into the operative network of FaEO, an enone oxidoreductase from Fragaria x ananassa Duch.

    PubMed

    Collu, Gabriella; Farci, Domenica; Esposito, Francesca; Pintus, Francesca; Kirkpatrick, Joanna; Piano, Dario

    2017-05-01

    The 2-methylene-furan-3-one reductase or Fragaria x ananassa Enone Oxidoreductase (FaEO) catalyses the last reductive step in the biosynthesis of 4-hydroxy-2,5-dimethyl-3(2H)-furanone, a major component in the characteristic flavour of strawberries. In the present work, we describe the association between FaEO and the vacuolar membrane of strawberry fruits. Even if FaEO lacks epitopes for stable or transient membrane-interactions, it contains a calmodulin-binding region, suggesting that in vivo FaEO may be associated with the membrane via a peripheral protein complex with calmodulin. Moreover, we also found that FaEO occurs in dimeric form in vivo and, as frequently observed for calmodulin-regulated proteins, it may be expressed in different isoforms by alternative gene splicing. Further mass spectrometry analysis confirmed that the isolated FaEO consists in the already known isoform and that it is the most characteristic during ripening. Finally, a characterization by absorption spectroscopy showed that FaEO has specific flavoprotein features. The relevance of these findings and their possible physiological implications are discussed.

  6. Searching for Sterile Neutrinos with MINOS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timmons, Ashley

    2016-01-01

    This document presents the latest results for a 3+1 sterile neutrino search using themore » $$10.56 \\times 10^{20}$$ protons-on-target data set taken from 2005 - 2012. By searching for oscillations driven by a large mass splitting, MINOS is sensitive to the existence of sterile neutrinos through any energy dependent deviations using a charged current sample, as well as looking at any relative deficit between neutral current events between the far and near detectors. This document will discuss the novel analysis that enabled a search for sterile neutrinos setting a limit in the previously unexplored regions in the parameter space $$\\{\\Delta m^{2}_{41}, \\sin^2\\theta_{24}\\}$$. The results presented can be compared to the parameter space suggested by LSND and MiniBooNE and complements other previous experimental searches for sterile neutrinos in the electron neutrino appearance channel.« less

  7. Centaurus A galaxy, type EO peculiar elliptical, also radio source

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Centaurus A galaxy, type EO peculiar elliptical, also radio source. CTIO 4-meter telescope, 1975. NGC 5128, a Type EO peculiar elliptical galaxy in the constellation Centaurus. This galaxy is one of the most luminous and massive galaxies known and is a strong source of both radio and X-ray radiation. Current theories suggest that the nucleus is experiencing giant explosions involving millions of stars and that the dark band across the galactic disk is material being ejected outward. Cerro Toloto 4-meter telescope photo. Photo credit: National Optical Astronomy Observatories

  8. Guidance, navigation, and control subsystem for the EOS-AM spacecraft

    NASA Technical Reports Server (NTRS)

    Linder, David M.; Tolek, Joseph T.; Lombardo, John

    1992-01-01

    This paper presents the preliminary design of the Guidance, Navigation, and Control (GN&C) subsystem for the EOS-AM spacecraft and specifically focuses on the GN&C Normal Mode design. First, a brief description of the EOS-AM science mission, instruments, and system-level spacecraft design is provided. Next, an overview of the GN&C subsystem functional and performance requirements, hardware, and operating modes is presented. Then, the GN&C Normal Mode attitude determination, attitude control, and navigation systems are detailed. Finally, descriptions of the spacecraft's overall jitter performance and Safe Mode are provided.

  9. Science synergism study for EOS on evolution of desert surfaces

    NASA Technical Reports Server (NTRS)

    Farr, Tom G.

    1987-01-01

    The effectiveness of EOS data as a basis for the study of desert surfaces' evolution is presently evaluated for both long and short term geomorphic evolution. Attention is given to the usefulness of such sensor systems planned for EOS as MODIS for regional vegetation distribution/variability monitoring, HIRIS for visible-near IR observations, TIMS for lithological identification, HMMR and SSMI for soil characteristics, LASA for atmospheric profiles, SAR for surface roughness, ALT for two-dimensional topography, ACR for the calibration of imaging sensors, and ERBE for climate modeling and regional surface albedo variation determinations.

  10. Allelic interaction of F1 pollen sterility loci and abnormal chromosome behaviour caused pollen sterility in intersubspecific autotetraploid rice hybrids.

    PubMed

    He, J H; Shahid, M Q; Li, Y J; Guo, H B; Cheng, X A; Liu, X D; Lu, Y G

    2011-08-01

    The intersubspecific hybrids of autotetraploid rice has many features that increase rice yield, but lower seed set is a major hindrance in its utilization. Pollen sterility is one of the most important factors which cause intersubspecific hybrid sterility. The hybrids with greater variation in seed set were used to study how the F(1) pollen sterile loci (S-a, S-b, and S-c) interact with each other and how abnormal chromosome behaviour and allelic interaction of F(1) sterility loci affect pollen fertility and seed set of intersubspecific autotetraploid rice hybrids. The results showed that interaction between pollen sterility loci have significant effects on the pollen fertility of autotetraploid hybrids, and pollen fertility further decreased with an increase in the allelic interaction of F(1) pollen sterility loci. Abnormal ultra-structure and microtubule distribution patterns during pollen mother cell (PMC) meiosis were found in the hybrids with low pollen fertility in interphase and leptotene, suggesting that the effect-time of pollen sterility loci interaction was very early. There were highly significant differences in the number of quadrivalents and bivalents, and in chromosome configuration among all the hybrids, and quadrivalents decreased with an increase in the seed set of autotetraploid hybrids. Many different kinds of chromosomal abnormalities, such as chromosome straggling, chromosome lagging, asynchrony of chromosome disjunction, and tri-fission were found during the various developmental stages of PMC meiosis. All these abnormalities were significantly higher in sterile hybrids than in fertile hybrids, suggesting that pollen sterility gene interactions tend to increase the chromosomal abnormalities which cause the partial abortion of male gametes and leads to the decline in the seed set of the autotetraploid rice hybrids. © 2011 The Author(s).

  11. Sterilization of slide sheath anesthetic injection systems placed within sharps containers.

    PubMed

    Palenik, C J; Burke, F J; Bose, M; Altweis, M L

    1997-01-01

    The purpose of this study was to evaluate the effect that two steam autoclaves and an unsaturated chemical vapor sterilizer had on killing bacterial endospores present on commercial spore strips or applied to sterile anesthetic injection systems placed within sharps containers. Three types of sterilizers were used: a gravity steam autoclave, a high vacuum steam autoclave and an unsaturated chemical vapor sterilizer. The microbial challenge for the sterilizers were Bacillus stearothermophilus spores present on commercial spore strips or drawn into and applied onto sliding sheath anesthetic injection systems with anesthetic carpules attached. Spore-soiled items were placed into the middle of sharps containers three-quarters-filled with representative clinical waste and sterilized. If, after culturing, sterilization of all test items in a group was not achieved, additional sterilization time was applied. Spore strips were killed within a single cycle of each sterilizer. Spore-soiled injection systems and carpules could not be routinely sterilized in the gravity steam autoclave or unsaturated chemical vapor sterilizers, even after three consecutive sterilization cycles. These items, however, were sterilized by exposure to a single-treatment cycle in a high-vacuum steam autoclave. Results indicate that routine sterilization of spore contaminated anesthetic carpules or injection systems could not be accomplished in a reasonable amount of time using sterilizers commonly found in dental offices.

  12. EO-Performance relationships in Reverse Internationalization by Chinese Global Startup OEMs: Social Networks and Strategic Flexibility.

    PubMed

    Chin, Tachia; Tsai, Sang-Bing; Fang, Kai; Zhu, Wenzhong; Yang, Dongjin; Liu, Ren-Huai; Tsuei, Richard Ting Chang

    2016-01-01

    Due to the context-sensitive nature of entrepreneurial orientation (EO), it is imperative to in-depth explore the EO-performance mechanism in China at its critical, specific stage of economic reform. Under the context of "reverse internationalization" by Chinese global startup original equipment manufacturers (OEMs), this paper aims to manifest the unique links and complicated interrelationships between the individual EO dimensions and firm performance. Using structural equation modeling, we found that during reverse internationalization, proactiveness is positively related to performance; risk taking is not statistically associated with performance; innovativeness is negatively related to performance. The proactiveness-performance relationship is mediated by Strategic flexibility and moderated by social networking relationships. The dynamic and complex institutional setting, coupled with the issues of overcapacity and rising labor cost in China may explain why our distinctive results occur. This research advances the understanding of how contingent factors (social network relationships and strategic flexibility) facilitate entrepreneurial firms to break down institutional barriers and reap the most from EO. It brings new insights into how Chinese global startup OEMs draw on EO to undertake reverse internationalization, responding the calls for unraveling the heterogeneous characteristics of EO sub-dimensions and for more contextually-embedded treatment of EO-performance associations.

  13. EO-Performance relationships in Reverse Internationalization by Chinese Global Startup OEMs: Social Networks and Strategic Flexibility

    PubMed Central

    Chin, Tachia; Tsai, Sang-Bing; Fang, Kai; Zhu, Wenzhong; Yang, Dongjin; Liu, Ren-huai; Tsuei, Richard Ting Chang

    2016-01-01

    Due to the context-sensitive nature of entrepreneurial orientation (EO), it is imperative to in-depth explore the EO-performance mechanism in China at its critical, specific stage of economic reform. Under the context of “reverse internationalization” by Chinese global startup original equipment manufacturers (OEMs), this paper aims to manifest the unique links and complicated interrelationships between the individual EO dimensions and firm performance. Using structural equation modeling, we found that during reverse internationalization, proactiveness is positively related to performance; risk taking is not statistically associated with performance; innovativeness is negatively related to performance. The proactiveness-performance relationship is mediated by Strategic flexibility and moderated by social networking relationships. The dynamic and complex institutional setting, coupled with the issues of overcapacity and rising labor cost in China may explain why our distinctive results occur. This research advances the understanding of how contingent factors (social network relationships and strategic flexibility) facilitate entrepreneurial firms to break down institutional barriers and reap the most from EO. It brings new insights into how Chinese global startup OEMs draw on EO to undertake reverse internationalization, responding the calls for unraveling the heterogeneous characteristics of EO sub-dimensions and for more contextually-embedded treatment of EO-performance associations. PMID:27631368

  14. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  15. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  16. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  17. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  18. Color stability of shade guides after autoclave sterilization.

    PubMed

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  19. Sterilization of fermentation vessels by ethanol/water mixtures

    DOEpatents

    Wyman, Charles E.

    1999-02-09

    A method for sterilizing process fermentation vessels with a concentrated alcohol and water mixture integrated in a fuel alcohol or other alcohol production facility. Hot, concentrated alcohol is drawn from a distillation or other purification stage and sprayed into the empty fermentation vessels. This sterilizing alcohol/water mixture should be of a sufficient concentration, preferably higher than 12% alcohol by volume, to be toxic to undesirable microorganisms. Following sterilization, this sterilizing alcohol/water mixture can be recovered back into the same distillation or other purification stage from which it was withdrawn. The process of this invention has its best application in, but is not limited to, batch fermentation processes, wherein the fermentation vessels must be emptied, cleaned, and sterilized following completion of each batch fermentation process.

  20. Reionization in sterile neutrino cosmologies

    NASA Astrophysics Data System (ADS)

    Bose, Sownak; Frenk, Carlos S.; Hou, Jun; Lacey, Cedric G.; Lovell, Mark R.

    2016-12-01

    We investigate the process of reionization in a model in which the dark matter is a warm elementary particle such as a sterile neutrino. We focus on models that are consistent with the dark matter decay interpretation of the recently detected line at 3.5 keV in the X-ray spectra of galaxies and clusters. In warm dark matter models, the primordial spectrum of density perturbations has a cut-off on the scale of dwarf galaxies. Structure formation therefore begins later than in the standard cold dark matter (CDM) model and very few objects form below the cut-off mass scale. To calculate the number of ionizing photons, we use the Durham semi-analytic model of galaxy formation, GALFORM. We find that even the most extreme 7 keV sterile neutrino we consider is able to reionize the Universe early enough to be compatible with the bounds on the epoch of reionization from Planck. This, perhaps surprising, result arises from the rapid build-up of high redshift galaxies in the sterile neutrino models which is also reflected in a faster evolution of their far-UV luminosity function between 10 > z > 7 than in CDM. The dominant sources of ionizing photons are systematically more massive in the sterile neutrino models than in CDM. As a consistency check on the models, we calculate the present-day luminosity function of satellites of Milky Way-like galaxies. When the satellites recently discovered in the Dark Energy Survey are taken into account, strong constraints are placed on viable sterile neutrino models.

  1. Revisiting cosmological bounds on sterile neutrinos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vincent, Aaron C.; Martínez, Enrique Fernández; Hernández, Pilar

    2015-04-01

    We employ state-of-the art cosmological observables including supernova surveys and BAO information to provide constraints on the mass and mixing angle of a non-resonantly produced sterile neutrino species, showing that cosmology can effectively rule out sterile neutrinos which decay between BBN and the present day. The decoupling of an additional heavy neutrino species can modify the time dependence of the Universe's expansion between BBN and recombination and, in extreme cases, lead to an additional matter-dominated period; while this could naively lead to a younger Universe with a larger Hubble parameter, it could later be compensated by the extra radiation expectedmore » in the form of neutrinos from sterile decay. However, recombination-era observables including the Cosmic Microwave Background (CMB), the shift parameter R{sub CMB} and the sound horizon r{sub s} from Baryon Acoustic Oscillations (BAO) severely constrain this scenario. We self-consistently include the full time-evolution of the coupled sterile neutrino and standard model sectors in an MCMC, showing that if decay occurs after BBN, the sterile neutrino is essentially bounded by the constraint sin{sup 2}θ ∼< 0.026 (m{sub s}/eV){sup −2}.« less

  2. The Coercive Sterilization of Aboriginal Women in Canada

    ERIC Educational Resources Information Center

    Stote, Karen

    2012-01-01

    This paper considers the coercive sterilization of Aboriginal women in legislated and non-legislated form in Canada. I provide an historical and materialist critique of coercive sterilization. I argue for coercive sterilization to be understood as one of many policies employed to undermine Aboriginal women, to separate Aboriginal peoples from…

  3. Committee Opinion No. 695: Sterilization of Women: Ethical Issues and Considerations.

    PubMed

    2017-04-01

    Sterilization is the most common method of contraception among married couples, with nearly twice as many couples choosing female partner sterilization over male sterilization. Although sterilization is among the most straightforward surgical procedures an obstetrician-gynecologist performs, it is enormously complex when considered from a historical, sociological, or ethical perspective. Sterilization practices have embodied a problematic tension, in which some women who desired fertility were sterilized without their knowledge or consent, and other women who wanted sterilization to limit their family size lacked access to it. An ethical approach to the provision of sterilization must, therefore, promote access for women who wish to use sterilization as a method of contraception, but at the same time safeguard against coercive or otherwise unjust uses. This Committee Opinion reviews ethical issues related to the sterilization of women and outlines an approach to providing permanent sterilization within a reproductive justice framework that recognizes that all women have a right to pursue and to prevent pregnancy.

  4. New RADIOM algorithm using inverse EOS

    NASA Astrophysics Data System (ADS)

    Busquet, Michel; Sokolov, Igor; Klapisch, Marcel

    2012-10-01

    The RADIOM model, [1-2], allows one to implement non-LTE atomic physics with a very low extra CPU cost. Although originally heuristic, RADIOM has been physically justified [3] and some accounting for auto-ionization has been included [2]. RADIOM defines an ionization temperature Tz derived from electronic density and actual electronic temperature Te. LTE databases are then queried for properties at Tz and NLTE values are derived from them. Some hydro-codes (like FAST at NRL, Ramis' MULTI, or the CRASH code at U.Mich) use inverse EOS starting from the total internal energy Etot and returning the temperature. In the NLTE case, inverse EOS requires to solve implicit relations between Te, Tz, and Etot. We shall describe these relations and an efficient solver successively implemented in some of our codes. [4pt] [1] M. Busquet, Radiation dependent ionization model for laser-created plasmas, Ph. Fluids B 5, 4191 (1993).[0pt] [2] M. Busquet, D. Colombant, M. Klapisch, D. Fyfe, J. Gardner. Improvements to the RADIOM non-LTE model, HEDP 5, 270 (2009).[0pt] [3] M.Busquet, Onset of pseudo-thermal equilibrium within configurations and super-configurations, JQSRT 99, 131 (2006)

  5. Accuracy Considerations in Sterile Compounding.

    PubMed

    Akers, Michael J

    2017-01-01

    Published information about the accuracy of filling and closing operations of sterile products is limited and guidelines on the topic are very general. This article highlights the basic principles in sterile-product filling of syringes and vials. Also covered in this article are descriptions of some of the available devices for filling containers, a brief discussion of the advances in vial and syringe filling, a discussion on the advantages and disadvantages of sterile product filling methods, and a discussion on possible problems encountered during filling operations. Because of the extremely high costs of some new drugs, especially biopharmaceuticals, compounding pharmacies may prefer to fill small batches to reduce the risk of unacceptable monetary losses in the event of a manufacturing deviation that results in batch rejection. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  6. Comparative dose levels between CT-scanner and slot-scanning device (EOS system) in pregnant women pelvimetry.

    PubMed

    Ben Abdennebi, A; Aubry, S; Ounalli, L; Fayache, M S; Delabrousse, E; Petegnief, Y

    2017-01-01

    To estimate fetal absorbed doses for pregnant women pelvimetry, a comparative study between EOS imaging system and low-dose spiral CT-scanner was carried out. For this purpose three different studies were investigated: in vivo, in vitro and Monte Carlo calculations. In vivo dosimetry was performed, using OSL NanoDot dosimeters, to determine the dose to the skin of twenty pregnant women. In vitro studies were established by using a cubic phantom of water, in order to estimate the out of field doses. In the latter study, OSLDs were placed at depths corresponding to the lowest, average and highest position of the uterus. Monte Carlo calculations of effective doses to high radio-sensitive organs were established, using PCXMC and CTExpo software suites for EOS imaging system and CT-scanner, respectively. The EOS imaging system reduces radiation exposure 4 to 8 times compared to the CT-scanner. The entrance skin doses were 74% (p-values <0.01) higher with the CT-scanner than with the EOS system. In the out of field region, the measured doses of the EOS system were reduced by 80% (p-values <0.02). Monte Carlo calculations confirmed that effective doses to organs are less accentuated for EOS than for CT pelvimetry. The EOS system is less irradiating than the CT exam. The out-of-field dose which is significant, is lower in the EOS than in the CT-scanner and could be reduced even further by optimizing the time used for image acquisition. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. A Shipping Container-Based Sterile Processing Unit for Low Resources Settings

    PubMed Central

    2016-01-01

    Deficiencies in the sterile processing of medical instruments contribute to poor outcomes for patients, such as surgical site infections, longer hospital stays, and deaths. In low resources settings, such as some rural and semi-rural areas and secondary and tertiary cities of developing countries, deficiencies in sterile processing are accentuated due to the lack of access to sterilization equipment, improperly maintained and malfunctioning equipment, lack of power to operate equipment, poor protocols, and inadequate quality control over inventory. Inspired by our sterile processing fieldwork at a district hospital in Sierra Leone in 2013, we built an autonomous, shipping-container-based sterile processing unit to address these deficiencies. The sterile processing unit, dubbed “the sterile box,” is a full suite capable of handling instruments from the moment they leave the operating room to the point they are sterile and ready to be reused for the next surgery. The sterile processing unit is self-sufficient in power and water and features an intake for contaminated instruments, decontamination, sterilization via non-electric steam sterilizers, and secure inventory storage. To validate efficacy, we ran tests of decontamination and sterilization performance. Results of 61 trials validate convincingly that our sterile processing unit achieves satisfactory outcomes for decontamination and sterilization and as such holds promise to support healthcare facilities in low resources settings. PMID:27007568

  8. EOS MLS Level 1B Data Processing, Version 2.2

    NASA Technical Reports Server (NTRS)

    Perun, Vincent; Jarnot, Robert; Pickett, Herbert; Cofield, Richard; Schwartz, Michael; Wagner, Paul

    2009-01-01

    A computer program performs level- 1B processing (the term 1B is explained below) of data from observations of the limb of the Earth by the Earth Observing System (EOS) Microwave Limb Sounder (MLS), which is an instrument aboard the Aura spacecraft. This software accepts, as input, the raw EOS MLS scientific and engineering data and the Aura spacecraft ephemeris and attitude data. Its output consists of calibrated instrument radiances and associated engineering and diagnostic data. [This software is one of several computer programs, denoted product generation executives (PGEs), for processing EOS MLS data. Starting from level 0 (representing the aforementioned raw data, the PGEs and their data products are denoted by alphanumeric labels (e.g., 1B and 2) that signify the successive stages of processing.] At the time of this reporting, this software is at version 2.2 and incorporates improvements over a prior version that make the code more robust, improve calibration, provide more diagnostic outputs, improve the interface with the Level 2 PGE, and effect a 15-percent reduction in file sizes by use of data compression.

  9. Status of Current and Future Remote Sensing with EO-1 Hyperion

    NASA Technical Reports Server (NTRS)

    Ungar, Stephen

    2006-01-01

    The Earth Observing-One (EO-1) satellite, launched in November of 2000, will complete six full years of operation near the end of this year. Observations from the Hyperion Imaging Spectrometer on board EO-1 have contributed to over 300 papers in refereed journals, conference proceeds and other presentations. Hyperion has been used to study a variety of natural and anthropogenic phenomena including hazards and catastrophes, agricultural health and productivity, ecological disturbance/development, and land use/land cover change. As an example, Hyperion has been used in hazard and catastrophe studies to monitor and assess effects of tsunamis, earthquakes, volcanic eruptions, mudslides, tornadoes, hurricanes, wild-fires (natural and human ignited), oil spills, and the aftermath of world trade center bombing. This presentation summarizes the current status of EO-1 Hyperion in terms of key scientific findings to date and future plans for operation of this instrument through 2007.

  10. Sterilization of fermentation vessels by ethanol/water mixtures

    DOEpatents

    Wyman, C.E.

    1999-02-09

    A method is described for sterilizing process fermentation vessels with a concentrated alcohol and water mixture integrated in a fuel alcohol or other alcohol production facility. Hot, concentrated alcohol is drawn from a distillation or other purification stage and sprayed into the empty fermentation vessels. This sterilizing alcohol/water mixture should be of a sufficient concentration, preferably higher than 12% alcohol by volume, to be toxic to undesirable microorganisms. Following sterilization, this sterilizing alcohol/water mixture can be recovered back into the same distillation or other purification stage from which it was withdrawn. The process of this invention has its best application in, but is not limited to, batch fermentation processes, wherein the fermentation vessels must be emptied, cleaned, and sterilized following completion of each batch fermentation process. 2 figs.

  11. Enhancement to Hitran to Support the NASA EOS Program

    NASA Technical Reports Server (NTRS)

    Kirby, Kate P.; Rothman, Laurence S.

    1998-01-01

    The HITRAN molecular database has been enhanced with the object of providing improved capabilities for the EOS program scientists. HITRAN itself is the database of high-resolution line parameters of gaseous species expected to be observed by the EOS program in its remote sensing activities. The database is part of a larger compilation that includes IR cross-sections, aerosol indices of refraction, and software for filtering and plotting portions of the database. These properties have also been improved. The software has been advanced in order to work on multiple platforms. Besides the delivery of the compilation on CD-ROM, the effort has been directed toward making timely access of data and software on the world wide web.

  12. Enhancement to HITRAN to Support the NASA EOS Program

    NASA Technical Reports Server (NTRS)

    Kirby, Kate P.; Rothman, Laurence S.

    1999-01-01

    The HITRAN molecular database has been enhanced with the object of providing improved capabilities for the EOS program scientists. HITRAN itself is the database of high-resolution line parameters of gaseous species expected to be observed by the EOS program in its remote sensing activities. The database is part of a larger compilation that includes IR cross-sections, aerosol indices of refraction, and software for filtering and plotting portions of the database. These properties have also been improved. The software has been advanced in order to work on multiple platforms. Besides the delivery of the compilation on CD-ROM, the effort has been directed toward making timely access of data and software on the world wide web.

  13. Promoting Strategic STEM Education Outreach Programming Using a Systems-Based STEM-EO Model

    ERIC Educational Resources Information Center

    Ward, Annmarie R.

    2015-01-01

    In this paper a STEM Education Outreach (STEM-EO) Model for promoting strategic university outreach programming at Penn State University to the benefit of university, school district and community stakeholders is described. The model considers STEM-EO as a complex system involving overarching learning goals addressed within four outreach domains…

  14. Continuous-sterilization system that uses photosemiconductor powders. [Escherichia coli

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsunaga, T.; Tomoda, R.; Nakajima, T.

    1988-06-01

    We report a novel photochemical sterilization system in which Escherichia coli cells were sterilized with photosemiconductor powders (titanium oxide). For sterilization that could be used in practice, it was necessary to separate the TiO/sub 2/ powders from the cell suspension. Therefore, semiconductor powders were immobilized on acetylcellulose membranes. We constructed a continuous-sterilization system consisting of TiO/sub 2/-immobilized acetylcellulose membrane reactor, a mercury lamp, and a masterflex pump. As a result, under the various sterilization conditions examined, E.coli (10/sup 2/ cells per ml) was sterilized to < 1% survival when the cell suspension flowed in this system at a mean residencemore » time of 16.0 min under irradiation (1800 microeinsteins/m/sup 2/ per s). We found that this system was reusable.« less

  15. Biological Sterilization of Returned Mars Samples

    NASA Technical Reports Server (NTRS)

    Allen, C. C.; Albert, F. G.; Combie, J.; Bodnar, R. J.; Hamilton, V. E.; Jolliff, B. L.; Kuebler, K.; Wang, A.; Lindstrom, D. J.; Morris, P. A.

    1999-01-01

    Martian rock and soil, collected by robotic spacecraft, will be returned to terrestrial laboratories early in the next century. Current plans call for the samples to be immediately placed into biological containment and tested for signs of present or past life and biological hazards. It is recommended that "Controlled distribution of unsterilized materials from Mars should occur only if rigorous analyses determine that the materials do not constitute a biological hazard. If any portion of the sample is removed from containment prior to completion of these analyses it should first be sterilized." While sterilization of Mars samples may not be required, an acceptable method must be available before the samples are returned to Earth. The sterilization method should be capable of destroying a wide range of organisms with minimal effects on the geologic samples. A variety of biological sterilization techniques and materials are currently in use, including dry heat, high pressure steam, gases, plasmas and ionizing radiation. Gamma radiation is routinely used to inactivate viruses and destroy bacteria in medical research. Many commercial sterilizers use Co-60 , which emits gamma photons of 1.17 and 1.33 MeV. Absorbed doses of approximately 1 Mrad (10(exp 8) ergs/g) destroy most bacteria. This study investigates the effects of lethal doses of Co-60 gamma radiation on materials similar to those anticipated to be returned from Mars. The goals are to determine the gamma dose required to kill microorganisms in rock and soil samples and to determine the effects of gamma sterilization on the samples' isotopic, chemical and physical properties. Additional information is contained in the original extended abstract.

  16. Earth Observing System (EOS)/Advanced Microwave Sounding Unit-A (AMSU-A) software assurance plan

    NASA Technical Reports Server (NTRS)

    Schwantje, Robert; Smith, Claude

    1994-01-01

    This document defines the responsibilities of Software Quality Assurance (SOA) for the development of the flight software installed in EOS/AMSU-A instruments, and the ground support software used in the test and integration of the EOS/AMSU-A instruments.

  17. Spore-Forming Bacteria that Resist Sterilization

    NASA Technical Reports Server (NTRS)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  18. Production of a sterile species: Quantum kinetics

    NASA Astrophysics Data System (ADS)

    Boyanovsky, D.; Ho, C. M.

    2007-10-01

    Production of a sterile species is studied within an effective model of active-sterile neutrino mixing in a medium in thermal equilibrium. The quantum kinetic equations for the distribution functions and coherences are obtained from two independent methods: the effective action and the quantum master equation. The decoherence time scale for active-sterile oscillations is τdec=2/Γaa, but the evolution of the distribution functions is determined by the two different time scales associated with the damping rates of the quasiparticle modes in the medium: Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where Γaa is the interaction rate of the active species in the absence of mixing and θm the mixing angle in the medium. These two time scales are widely different away from Mikheyev-Smirnov-Wolfenstein resonances and preclude the kinetic description of active-sterile production in terms of a simple rate equation. We give the complete set of quantum kinetic equations for the active and sterile populations and coherences and discuss in detail the various approximations. A generalization of the active-sterile transition probability in a medium is provided via the quantum master equation. We derive explicitly the usual quantum kinetic equations in terms of the “polarization vector” and show their equivalence to those obtained from the quantum master equation and effective action.

  19. Sterilization of Lung Matrices by Supercritical Carbon Dioxide

    PubMed Central

    Balestrini, Jenna L.; Liu, Angela; Gard, Ashley L.; Huie, Janet; Blatt, Kelly M.S.; Schwan, Jonas; Zhao, Liping; Broekelmann, Tom J.; Mecham, Robert P.; Wilcox, Elise C.

    2016-01-01

    Lung engineering is a potential alternative to transplantation for patients with end-stage pulmonary failure. Two challenges critical to the successful development of an engineered lung developed from a decellularized scaffold include (i) the suppression of resident infectious bioburden in the lung matrix, and (ii) the ability to sterilize decellularized tissues while preserving the essential biological and mechanical features intact. To date, the majority of lungs are sterilized using high concentrations of peracetic acid (PAA) resulting in extracellular matrix (ECM) depletion. These mechanically altered tissues have little to no storage potential. In this study, we report a sterilizing technique using supercritical carbon dioxide (ScCO2) that can achieve a sterility assurance level 10−6 in decellularized lung matrix. The effects of ScCO2 treatment on the histological, mechanical, and biochemical properties of the sterile decellularized lung were evaluated and compared with those of freshly decellularized lung matrix and with PAA-treated acellular lung. Exposure of the decellularized tissue to ScCO2 did not significantly alter tissue architecture, ECM content or organization (glycosaminoglycans, elastin, collagen, and laminin), observations of cell engraftment, or mechanical integrity of the tissue. Furthermore, these attributes of lung matrix did not change after 6 months in sterile buffer following sterilization with ScCO2, indicating that ScCO2 produces a matrix that is stable during storage. The current study's results indicate that ScCO2 can be used to sterilize acellular lung tissue while simultaneously preserving key biological components required for the function of the scaffold for regenerative medicine purposes. PMID:26697757

  20. Cleaning, disinfection and sterilization of surface prion contamination.

    PubMed

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  1. Compact liquid crystal waveguide based fourier transform spectrometer for in-situ and remote gas and chemical sensing

    NASA Astrophysics Data System (ADS)

    Chao, Tien-Hsin; Davis, Scott R.; Rommel, Scott D.; Farca, George; Luey, Ben; Martin, Alan; Anderson, Michael H.

    2009-11-01

    Jet Propulsion Lab and Vescent Photonics Inc. are jointly developing an innovative ultra-compact (volume < 10 cm3), ultra-low power (<10-3 Watt-hours per measurement and zero power consumption when not measuring), completely nonmechanical electro-optic Fourier transform spectrometers (EO-FTS) that will be suitable for a variety of remoteplatform, in-situ measurements. This EO-FTS consists of: i) a novel electro-evanescent waveguide architecture as the solid-state time delay device whose optical path difference (OPD) can be precisely varied utilizing voltage control, ii) a photodetector diode, and iii) an external light/sample collecting devices tailored for either in-situ gas and/or rock sample analysis or for remote atmospheric gas analysis. These devices are made possible by a novel electro-evanescent waveguide architecture, enabling "chip-scale" EO-FTS sensors. The potential performance of these EO-FTS sensors include: i) a spectral range throughout 0.4-5 μm (25000 - 2000 cm-1), ii) high-resolution ▵λ <= 0.1 nm), iii) high-speed (< 1 ms) measurements, and iv) rugged integrated optical construction. This performance potential enables the detection and quantification of a large number of different atmospheric gases simultaneously in the same air mass and the rugged construction will enable deployment on previously inaccessible platforms. In this paper, the up-to-date EO-FTS sensor development status will be presented; initial experimental results will also be demonstrated.

  2. An Overview of the EOS Data Dissemination Systems

    NASA Technical Reports Server (NTRS)

    Ramapriyan, H.K.; Pfister, Robin; Weinstein, Beth

    2008-01-01

    The Earth Observing System Data and Information System (EOSDIS) is the primary data system serving the broad-scope of NASA s Earth Observing System (EOS) program and a significant portion of the "heritage" Earth science data. EOSDIS was designed to support the Earth sciences within NASA s Science Mission Directorate (previously the Earth Science Enterprise (ESE) and Mission to Planet Earth). The EOS Program was NASA s contribution to the United States Global Change Research Program (USGCRP) enacted by Congress in 1990 as part of the Global Change Act. ESE s objective was to launch a series of missions to help answer fundamental global change questions such as "How is Earth changing?" and "What are the consequences for life on Earth?" resulting support of this objective, EOSDIS distributes a wide variety of data to a diverse community.

  3. Earth Observing System (EOS) Communication (Ecom) Modeling, Analysis, and Testbed (EMAT) activiy

    NASA Technical Reports Server (NTRS)

    Desai, Vishal

    1994-01-01

    This paper describes the Earth Observing System (EOS) Communication (Ecom) Modeling, Analysis, and Testbed (EMAT) activity performed by Code 540 in support of the Ecom project. Ecom is the ground-to-ground data transport system for operational EOS traffic. The National Aeronautic and Space Administration (NASA) Communications (Nascom) Division, Code 540, is responsible for implementing Ecom. Ecom interfaces with various systems to transport EOS forward link commands, return link telemetry, and science payload data. To understand the complexities surrounding the design and implementation of Ecom, it is necessary that sufficient testbedding, modeling, and analysis be conducted prior to the design phase. These activities, when grouped, are referred to as the EMAT activity. This paper describes work accomplished to date in each of the three major EMAT activities: modeling, analysis, and testbedding.

  4. Sterile neutrino searches via displaced vertices at LHCb

    NASA Astrophysics Data System (ADS)

    Antusch, Stefan; Cazzato, Eros; Fischer, Oliver

    2017-11-01

    We explore the sensitivity of displaced vertex searches at LHCb for testing sterile neutrino extensions of the Standard Model towards explaining the observed neutrino masses. We derive estimates for the constraints on sterile neutrino parameters from a recently published displaced vertex search at LHCb based on run 1 data. They yield the currently most stringent limit on active-sterile neutrino mixing in the sterile neutrino mass range between 4.5 GeV and 10 GeV. Furthermore, we present forecasts for the sensitivities that could be obtained from the run 2 data and also for the high-luminosity phase of the LHC.

  5. Reliability of laparoscopic compared with hysteroscopic sterilization at 1 year: a decision analysis.

    PubMed

    Gariepy, Aileen M; Creinin, Mitchell D; Schwarz, Eleanor B; Smith, Kenneth J

    2011-08-01

    To estimate the probability of successful sterilization after an hysteroscopic or laparoscopic sterilization procedure. An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. In the base case analysis, the proportion of women having a successful sterilization procedure on the first attempt is 99% for laparoscopic sterilization, 88% for hysteroscopic sterilization in the operating room, and 87% for hysteroscopic sterilization in the office. The probability of having a successful sterilization procedure within 1 year is 99% with laparoscopic sterilization, 95% for hysteroscopic sterilization in the operating room, and 94% for hysteroscopic sterilization in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within 1 year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization.

  6. The Sterile Insect Technique for Controlling Populations of Aedes albopictus (Diptera: Culicidae) on Reunion Island: Mating Vigour of Sterilized Males

    PubMed Central

    Oliva, Clelia F.; Jacquet, Maxime; Gilles, Jeremie; Lemperiere, Guy; Maquart, Pierre-Olivier; Quilici, Serge; Schooneman, François; Vreysen, Marc J. B.; Boyer, Sebastien

    2012-01-01

    Reunion Island suffers from high densities of the chikungunya and dengue vector Aedes albopictus. The sterile insect technique (SIT) offers a promising strategy for mosquito-borne diseases prevention and control. For such a strategy to be effective, sterile males need to be competitive enough to fulfil their intended function by reducing wild mosquito populations in natura. We studied the effect of irradiation on sexual maturation and mating success of males, and compared the sexual competitiveness of sterile versus wild males in the presence of wild females in semi-field conditions. For all untreated or sterile males, sexual maturation was completed within 13 to 20 h post-emergence and some males were able to inseminate females when 15 h old. In the absence of competition, untreated and sterile males were able to inseminate the same number of virgin females during 48 h, in small laboratory cages: an average of 93% of females was inseminated no matter the treatment, the age of males, and the sex ratio. Daily mating success of single sterile males followed the same pattern as for untreated ones, although they inseminated significantly fewer females after the ninth day. The competitiveness index of sterile males in semi-field conditions was only 0.14 when they were released at 1-day old, but improved to 0.53 when the release occurred after a 5-day period in laboratory conditions. In SIT simulation experiments, a 5∶1 sterile to wild male ratio allowed a two-fold reduction of the wild population’s fertility. This suggests that sterile males could be sufficiently competitive to mate with wild females within the framework of an SIT component as part of an AW-IPM programme for suppressing a wild population of Ae. albopictus in Reunion Island. It will be of interest to minimise the pre-release period in controlled conditions to ensure a good competitiveness without increasing mass rearing costs. PMID:23185329

  7. Outpatient laparoscopic interval female sterilization.

    PubMed

    Intaraprasert, S; Taneepanichskul, S; Chaturachinda, K

    1997-05-01

    A 23-year retrospective review of laparoscopic sterilization in Ramathibodi Hospital, Bangkok, Thailand, is reported. A total of 9041 cases of outpatient laparoscopic interval female sterilizations were done from January 1973 to December 1995. Intraoperative complications occurred in 35 cases (0.39%) and hospital admissions totalled 65 cases (0.72%). Adnexal injuries were the most frequent complication. There was one case of death from anesthetic complication. Management and prevention of complications are discussed.

  8. A Reference Implementation of the OGC CSW EO Standard for the ESA HMA-T project

    NASA Astrophysics Data System (ADS)

    Bigagli, Lorenzo; Boldrini, Enrico; Papeschi, Fabrizio; Vitale, Fabrizio

    2010-05-01

    This work was developed in the context of the ESA Heterogeneous Missions Accessibility (HMA) project, whose main objective is to involve the stakeholders, namely National space agencies, satellite or mission owners and operators, in an harmonization and standardization process of their ground segment services and related interfaces. Among HMA objectives was the specification, conformance testing, and experimentation of two Extension Packages (EPs) of the ebRIM Application Profile (AP) of the OGC Catalog Service for the Web (CSW) specification: the Earth Observation Products (EO) EP (OGC 06-131) and the Cataloguing of ISO Metadata (CIM) EP (OGC 07-038). Our contributions have included the development and deployment of Reference Implementations (RIs) for both the above specifications, and their integration with the ESA Service Support Environment (SSE). The RIs are based on the GI-cat framework, an implementation of a distributed catalog service, able to query disparate Earth and Space Science data sources (e.g. OGC Web Services, Unidata THREDDS) and to expose several standard interfaces for data discovery (e.g. OGC CSW ISO AP). Following our initial planning, the GI-cat framework has been extended in order to expose the CSW.ebRIM-CIM and CSW.ebRIM-EO interfaces, and to distribute queries to CSW.ebRIM-CIM and CSW.ebRIM-EO data sources. We expected that a mapping strategy would suffice for accommodating CIM, but this proved to be unpractical during implementation. Hence, a model extension strategy was eventually implemented for both the CIM and EO EPs, and the GI-cat federal model was enhanced in order to support the underlying ebRIM AP. This work has provided us with new insights into the different data models for geospatial data, and the technologies for their implementation. The extension is used by suitable CIM and EO profilers (front-end mediator components) and accessors (back-end mediator components), that relate ISO 19115 concepts to EO and CIM ones. Moreover

  9. NASA EO-1 Spacecraft Images Chile Volcanic Eruption

    NASA Image and Video Library

    2011-06-17

    On June 14, 2011, NASA Earth Observing-1 EO-1 spacecraft obtained this image showing ash-rich volcanic plume billowing out of the vent, punching through a low cloud layer. The plume grey color is a reflection of its ash content.

  10. EOS MLS Lessons Learned: Design Ideas for Safer and Lower Cost Operations

    NASA Technical Reports Server (NTRS)

    Miller, Dominick

    2012-01-01

    The Earth Observing System (EOS) Microwave Limb Sounder (MLS) is a complex instrument with a front end computer and 32 subsystem computers. MLS is one of four instruments on NASA's EOS Aura spacecraft With almost 8 years in orbit, MLS has a few lessons learned which can be applied during the design phase of future instruments to effect better longevity, more robust operations and a significant cost benefit during operations phase.

  11. Mechanism for the differentiation of EoL-1 cells into eosinophils by histone deacetylase inhibitors.

    PubMed

    Kaneko, Motoko; Ishihara, Kenji; Takahashi, Aki; Hong, Jangja; Hirasawa, Noriyasu; Zee, Okpyo; Ohuchi, Kazuo

    2007-01-01

    EoL-1 cells have a FIP1L1-PDGFRA fusion gene which causes the transformation of eosinophilic precursor cells into leukemia cells. Recently, we suggested that the induction of differentiation of EoL-1 cells into eosinophils by the HDAC inhibitors apicidin and n-butyrate is due to the continuous inhibition of HDACs. However, neither apicidin nor n-butyrate inhibited the expression of FIP1L1-PDGFRA mRNA, although both these inhibitors suppressed cell proliferation. Therefore, in this study, we analyzed whether the levels of FIP1L1-PDGFRalpha protein and phosphorylated-Stat5 involved in the signaling for the proliferation of EoL-1 cells are attenuated by HDAC inhibitors. EoL-1 cells were incubated in the presence of apicidin, TSA or n-butyrate. FIP1L1-PDGFRalpha and phosphorylated-Stat5 were detected by Western blotting. Treatment of EoL-1 cells with apicidin at 100 nM or n-butyrate at 500 microM decreased the levels of FIP1L1-PDGFRalpha protein and phosphorylated-Stat5, while that with trichostatin A at 30 nM did not. The decrease in the level of FIP1L1-PDGFRalpha protein caused by apicidin and n-butyrate might be one of the mechanisms by which EoL-1 cells are induced to differentiate into eosinophils by these HDAC inhibitors.

  12. The spectroscopy of solar sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Lopes, Ilídio

    2018-04-01

    We predict the sterile neutrino spectrum of some of the key solar nuclear reactions and discuss the possibility of these being observed by the next generation of solar neutrino experiments. By using an up-to-date standard solar model with good agreement with current helioseismology and solar neutrino flux data sets, we found that from solar neutrino fluxes arriving on Earth only 3-4% correspond to the sterile neutrino. The most intense solar sources of sterile neutrinos are the pp and ^7Be nuclear reactions with a total flux of 2.2× 109 and 1.8× 108{{cm}^2 {s}^{-1}}, followed by the ^{13}N and ^{15}O nuclear reactions with a total flux of 1.9× 107 and 1.7× 107{cm}^2 {s}^{-1}. Moreover, we compute the sterile neutrino spectra of the nuclear proton-proton nuclear reactions - pp, hep and ^8B and the carbon-nitrogen-oxygen - ^{13}N, ^{15}O and ^{17}F and the spectral lines of ^7Be.

  13. Aspects of detection and tracking of ground targets from an airborne EO/IR sensor

    NASA Astrophysics Data System (ADS)

    Balaji, Bhashyam; Sithiravel, Rajiv; Daya, Zahir; Kirubarajan, Thiagalingam

    2015-05-01

    An airborne EO/IR (electro-optical/infrared) camera system comprises of a suite of sensors, such as a narrow and wide field of view (FOV) EO and mid-wave IR sensors. EO/IR camera systems are regularly employed on military and search and rescue aircrafts. The EO/IR system can be used to detect and identify objects rapidly in daylight and at night, often with superior performance in challenging conditions such as fog. There exist several algorithms for detecting potential targets in the bearing elevation grid. The nonlinear filtering problem is one of estimation of the kinematic parameters from bearing and elevation measurements from a moving platform. In this paper, we developed a complete model for the state of a target as detected by an airborne EO/IR system and simulated a typical scenario with single target with 1 or 2 airborne sensors. We have demonstrated the ability to track the target with `high precision' and noted the improvement from using two sensors on a single platform or on separate platforms. The performance of the Extended Kalman filter (EKF) is investigated on simulated data. Image/video data collected from an IR sensor on an airborne platform are processed using an image tracking by detection algorithm.

  14. Microwave Sterilization and Depyrogenation System

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Dahl, Roger W.; Wheeler, Richard R., Jr.

    2009-01-01

    A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time

  15. Innovative non-thermal plasma disinfection process inside sealed bags: Assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms

    PubMed Central

    Charpentier, Emilie; Le-Bras, Florian; Maho, Thomas; Robert, Eric; Pouvesle, Jean-Michel; Polidor, Franck; Gangloff, Sophie C.; Boudifa, Mohamed

    2017-01-01

    In this work, we developed a device capable to generate a non-thermal plasma discharge inside a sealed bag. The aim of this study was to assess the effectiveness of the oxygen, nitrogen and argon plasma sterilization on Pseudomonas aeruginosa, Staphylococcus aureus and Bacillus subtilis spores according to the NF EN 556 Norm. Moreover the bag integrity which is a critical key to maintain the sterile state of items after the end of the process was verified by Fourier Transform Infrared (FTIR) and X-ray Photoelectron Spectrometry (XPS) analyses. After plasma treatments, the bacterial counting showed a 6 log reduction of P. aeruginosa and S. aureus in 45 min and 120 min respectively whatever the gas used and a 4 log reduction of B. subtilis spores in 120 min with only oxygen plasma. These results were confirmed by Scanning Electron Microscopy (SEM) observations showing altered bacteria or spores and numerous debris. Taking into account the studied microorganisms, the oxygen plasma treatment showed the highest efficiency. FTIR and XPS analyses showed that this treatment induced no significant modification of the bags. To conclude this non-thermal plasma sterilization technique could be an opportunity to sterilize heat and chemical-sensitive medical devices and to preserve their sterile state after the end of the process. PMID:28662202

  16. Earth Observing System (EOS) Snow and Ice Products for Observation and Modeling

    NASA Technical Reports Server (NTRS)

    Hall, D.; Kaminski, M.; Cavalieri, D.; Dickinson, R.; Marquis, M.; Riggs, G.; Robinson, D.; VanWoert, M.; Wolfe, R.

    2005-01-01

    Snow and ice are the key components of the Earth's cryosphere, and their influence on the Earth's energy balance is very significant due at least in part to the large areal extent and high albedo characterizing these features. Large changes in the cryosphere have been measured over the last century and especially over the past decade, and remote sensing plays a pivotal role in documenting these changes. Many of NASA's Earth Observing System (EOS) products derived from instruments on the Terra, Aqua, and Ice, Cloud and land Elevation Satellite (ICESat) satellites are useful for measuring changes in features that are associated with climate change. The utility of the products is continually enhanced as the length of the time series increases. To gain a more coherent view of the cryosphere and its historical and recent changes, the EOS products may be employed together, in conjunction with other sources of data, and in models. To further this goal, the first EOS Snow and Ice Products Workshop was convened. The specific goals of the workshop were to provide current and prospective users of EOS snow and ice products up-to-date information on the products, their validation status and future enhancements, to help users utilize the data products through hands-on demonstrations, and to facilitate the integration of EOS products into models. Oral and poster sessions representing a wide variety of snow and ice topics were held; three panels were also convened to discuss workshop themes. Panel discussions focused on data fusion and assimilation of the products into models. Approximately 110 people attended, representing a wide array of interests and organizations in the cryospheric community.

  17. Template-Independent Enzymatic Oligonucleotide Synthesis (TiEOS): Its History, Prospects, and Challenges.

    PubMed

    Jensen, Michael A; Davis, Ronald W

    2018-03-27

    There is a growing demand for sustainable methods in research and development, where instead of hazardous chemicals, an aqueous medium is chosen to perform biological reactions. In this Perspective, we examine the history and current methodology of using enzymes to generate artificial single-stranded DNA. By using traditional solid-phase phosphoramidite chemistry as a metric, we also explore criteria for the method of template-independent enzymatic oligonucleotide synthesis (TiEOS). As its key component, we delve into the biology of one of the most enigmatic enzymes, terminal deoxynucleotidyl transferase (TdT). As TdT is found to exponentially increase antigen receptor diversity in the vertebrate immune system by adding nucleotides in a template-free manner, researchers have exploited this function as an alternative to the phosphoramidite synthesis method. Though TdT is currently the preferred enzyme for TiEOS, its random nucleotide incorporation presents a barrier in synthesis automation. Taking a closer look at the TiEOS cycle, particularly the coupling step, we find it is comprised of additions > n+1 and deletions. By tapping into the physical and biochemical properties of TdT, we strive to further elucidate its mercurial behavior and offer ways to better optimize TiEOS for production-grade oligonucleotide synthesis.

  18. EOS Aqua: Mission Status at Earth Science Constellation

    NASA Technical Reports Server (NTRS)

    Guit, Bill

    2016-01-01

    This is an EOS Aqua Mission Status presentation to be given at the MOWG meeting in Albuquerque NM. The topics to discus are: mission summary, spacecraft subsystems summary, recent and planned activities, inclination adjust maneuvers, propellant usage and lifetime estimate, and mission summary.

  19. Atmospheric pressure dielectric barrier discharges for sterilization and surface treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chin, O. H.; Lai, C. K.; Choo, C. Y.

    2015-04-24

    Atmospheric pressure non-thermal dielectric barrier discharges can be generated in different configurations for different applications. For sterilization, a parallel-plate electrode configuration with glass dielectric that discharges in air was used. Gram-negative bacteria (Escherichia coli and Salmonella enteritidis) and Gram-positive bacteria (Bacillus cereus) were successfully inactivated using sinusoidal high voltage of ∼15 kVp-p at 8.5 kHz. In the surface treatment, a hemisphere and disc electrode arrangement that allowed a plasma jet to be extruded under controlled nitrogen gas flow (at 9.2 kHz, 20 kVp-p) was applied to enhance the wettability of PET (Mylar) film.

  20. Atmospheric pressure dielectric barrier discharges for sterilization and surface treatment

    NASA Astrophysics Data System (ADS)

    Chin, O. H.; Lai, C. K.; Choo, C. Y.; Wong, C. S.; Nor, R. M.; Thong, K. L.

    2015-04-01

    Atmospheric pressure non-thermal dielectric barrier discharges can be generated in different configurations for different applications. For sterilization, a parallel-plate electrode configuration with glass dielectric that discharges in air was used. Gram-negative bacteria (Escherichia coli and Salmonella enteritidis) and Gram-positive bacteria (Bacillus cereus) were successfully inactivated using sinusoidal high voltage of ˜15 kVp-p at 8.5 kHz. In the surface treatment, a hemisphere and disc electrode arrangement that allowed a plasma jet to be extruded under controlled nitrogen gas flow (at 9.2 kHz, 20 kVp-p) was applied to enhance the wettability of PET (Mylar) film.

  1. Sterile Neutrinos in Cold Climates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Benjamin J.P.

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Partmore » II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin 22θ 24 ≤ 0.02 at m 2 ~ 0.3 eV 2, and the LSND and MiniBooNE allowed regions are

  2. Earth Observing System (EOS) advanced altimetry

    NASA Technical Reports Server (NTRS)

    Parsons, C. L.; Walsh, E. J.

    1988-01-01

    In the post-TOPEX era, satellite radar altimeters will be developed with the capability of measuring the earth's surface topography over a wide swath of coverage, rather than just at the satellite's nadir. The identification of potential spacecraft flight missions in the future was studied. The best opportunity was found to be the Earth Observing System (EOS). It is felt that an instrument system that has a broad appeal to the earth sciences community stands a much better chance of being selected as an EOS instrument. Consequently, the Topography and Rain Radar Imager (TARRI) will be proposed as a system that has the capability to profile the Earth's topography regardless of the surface type. The horizontal and height resolutions of interest are obviously significantly different over land, ice, and water; but, the use of radar to provide an all-weather observation capability is applicable to the whole earth. The scientific guidance for the design and development of this instrument and the eventual scientific utilization of the data produced by the TARRI will be provided by seven science teams. The teams are formed around scientific disciplines and are titled: Geology/Geophysics, Hydrology/Rain, Oceanography, Ice/Snow, Geodesy/Orbit/Attitude, Cartography, and Surface Properties/Techniques.

  3. Effects of sterile neutrino and extra-dimension on big bang nucleosynthesis

    NASA Astrophysics Data System (ADS)

    Jang, Dukjae; Kusakabe, Motohiko; Cheoun, Myung-Ki

    2018-04-01

    We study effects of the sterile neutrino in the five-dimensional universe on the big bang nucleosynthesis (BBN). Since the five-dimensional universe model leads to an additional term in the Friedmann equation and the energy density of the sterile neutrino increases the total energy density, this model can affect the primordial abundance via changing the cosmic expansion rate. The energy density of the sterile neutrino can be determined by a rate equation for production of the sterile neutrino. We show that not only the mixing angle and the mass of the sterile neutrino, but also a resonant effect in the oscillation between sterile and active neutrinos is important to determine a relic abundance of the sterile neutrino. In this study, we also investigate how the sterile neutrino in extra-dimensional model can affect the BBN, and constrain the parameters related to the above properties of the sterile neutrino by using the observational primordial abundances of light elements.

  4. Orthodontic instrument sterilization with microwave irradiation.

    PubMed

    Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram

    2015-04-01

    This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups - Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min.

  5. Comparative transcript profiling of fertile and sterile flower buds from multiple-allele-inherited male sterility in Chinese cabbage (Brassica campestris L. ssp. pekinensis).

    PubMed

    Zhou, Xue; Liu, Zhiyong; Ji, Ruiqin; Feng, Hui

    2017-10-01

    We studied the underlying causes of multiple-allele-inherited male sterility in Chinese cabbage (Brassica campestris L. ssp. pekinensis) by identifying differentially expressed genes (DEGs) related to pollen sterility between fertile and sterile flower buds. In this work, we verified the stages of sterility microscopically and then performed transcriptome analysis of mRNA isolated from fertile and sterile buds using Illumina HiSeq 2000 platform sequencing. Approximately 80% of ~229 million high-quality paired-end reads were uniquely mapped to the reference genome. In sterile buds, 699 genes were significantly up-regulated and 4096 genes were down-regulated. Among the DEGs, 28 pollen cell wall-related genes, 54 transcription factor genes, 45 phytohormone-related genes, 20 anther and pollen-related genes, 212 specifically expressed transcripts, and 417 DEGs located on linkage group A07 were identified. Six transcription factor genes BrAMS, BrMS1, BrbHLH089, BrbHLH091, BrAtMYB103, and BrANAC025 were identified as putative sterility-related genes. The weak auxin signal that is regulated by BrABP1 may be one of the key factors causing pollen sterility observed here. Moreover, several significantly enriched GO terms such as "cell wall organization or biogenesis" (GO:0071554), "intrinsic to membrane" (GO:0031224), "integral to membrane" (GO:0016021), "hydrolase activity, acting on ester bonds" (GO:0016788), and one significantly enriched pathway "starch and sucrose metabolism" (ath00500) were identified in this work. qRT-PCR, PCR, and in situ hybridization experiments validated our RNA-seq transcriptome analysis as accurate and reliable. This study will lay the foundation for elucidating the molecular mechanism(s) that underly sterility and provide valuable information for studying multiple-allele-inherited male sterility in the Chinese cabbage line 'AB01'.

  6. Technical Reliability Studies. EOS/ESD Technology Abstracts

    DTIC Science & Technology

    1981-01-01

    MECHANISMS MELAMINE MESFETS MICROWAVE MIS 15025 AUTOMATIC MACHINE PRECAUTIONS FOR HOS/OiOS 15006 INSTRUCTIONS FOR INSTALLATION AND...ELIMINATION OF EOS INDUCED SECONDARY FAILURE MECHANISMS 15000 USE OF MELAMINE WORK-SURFACE FOR ESD POTENTIAL BLEED OFF 16141 MICROWAVE NANOSECOND... microwave devices, optoelectronics, and selected nonelectronic parts employed in military, space and commercial applications. In addition, a System

  7. Current techniques and outcomes in hysteroscopic sterilization: current evidence, considerations, and complications with hysteroscopic sterilization micro inserts.

    PubMed

    Casey, James; Cedo-Cintron, Laura; Pearce, Jessica; Yunker, Amanda

    2017-08-01

    To describe the current data regarding effectiveness, complications, postoperative evaluation, and surgical interventions associated with Essure hysteroscopic sterilization. Hysteroscopic sterilization is a commonly performed procedure that is offered as a well tolerated, effective, outpatient method of permanent sterilization. Over the past several years, concerns have been raised regarding correct placement and postoperative complications. This has led to statements by both the Food and Drug Administration (FDA) in October, 2016 and American Association of Gynecologic Laparoscopists in February, 2017, as a significant portion of women seek removal of these devices. A current black-box warning issued by the FDA in 2016 recommends discussion of 'the probabilities of rates or events' of adverse outcomes associated with Essure placement. Although hysteroscopic sterilization is usually a safe, effective option for permanent contraception, new evidence regarding complications has emphasized the need for proper education and counseling. Appropriate patient selection and knowledge of potential complications is paramount to ensuring patients, and medical providers are well informed and have realistic expectations regarding potential placement and postoperative issues.

  8. Earth Observing System (EOS) Terra Spacecraft 120 Volt Power Subsystem: Requirements, Development and Implementation

    NASA Technical Reports Server (NTRS)

    Keys, Denney J.

    2000-01-01

    Built by the Lockheed-Martin Corporation, the Earth Observing System (EOS) TERRA spacecraft represents the first orbiting application of a 120 Vdc high voltage spacecraft electrical power system implemented by the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC). The EOS TERRA spacecraft's launch provided a major contribution to the NASA Mission to Planet Earth program while incorporating many state of the art electrical power system technologies to achieve its mission goals. The EOS TERRA spacecraft was designed around five state-of-the-art scientific instrument packages designed to monitor key parameters associated with the earth's climate. The development focus of the TERRA electrical power system (EPS) resulted from a need for high power distribution to the EOS TERRA spacecraft subsystems and instruments and minimizing mass and parasitic losses. Also important as a design goal of the EPS was maintaining tight regulation on voltage and achieving low conducted bus noise characteristics. This paper outlines the major requirements for the EPS as well as the resulting hardware implementation approach adopted to meet the demands of the EOS TERRA low earth orbit mission. The selected orbit, based on scientific needs, to achieve the EOS TERRA mission goals is a sun-synchronous circular 98.2degree inclination Low Earth Orbit (LEO) with a near circular average altitude of 705 kilometers. The nominal spacecraft orbit is approximately 99 minutes with an average eclipse period of about 34 minutes. The scientific goal of the selected orbit is to maintain a repeated 10:30 a.m. +/- 15 minute descending equatorial crossing which provides a fairly clear view of the earth's surface and relatively low cloud interference for the instrument observation measurements. The major EOS TERRA EPS design requirements are single fault tolerant, average orbit power delivery of 2, 530 watts with a defined minimum lifetime of five years (EOL). To meet

  9. Committee Opinion No 695 Summary: Sterilization of Women: Ethical Issues and Considerations.

    PubMed

    2017-04-01

    Sterilization is the most common method of contraception among married couples, with nearly twice as many couples choosing female partner sterilization over male sterilization. Although sterilization is among the most straightforward surgical procedures an obstetrician-gynecologist performs, it is enormously complex when considered from a historical, sociological, or ethical perspective. Sterilization practices have embodied a problematic tension, in which some women who desired fertility were sterilized without their knowledge or consent, and other women who wanted sterilization to limit their family size lacked access to it. An ethical approach to the provision of sterilization must, therefore, promote access for women who wish to use sterilization as a method of contraception, but at the same time safeguard against coercive or otherwise unjust uses. This Committee Opinion reviews ethical issues related to the sterilization of women and outlines an approach to providing permanent sterilization within a reproductive justice framework that recognizes that all women have a right to pursue and to prevent pregnancy.

  10. Safe use of chemicals for sterilization in healthcare.

    PubMed

    Warburton, P Richard

    2012-01-01

    Chemical sterilization is necessary for temperature sensitive items that cannot be sterilized with steam. These chemical sterilants are by their nature hazardous; otherwise, they would not function well. Modern sterilizers and associated equipment are designed so that these chemicals can be used safely. Whether through mechanical failure, wear and tear, or user error, leaks do sometimes occur. The maximum chemical exposure is determined by OSHA permissible exposure limits, if available, and if not available, employers should use recognized standards. Employers have a duty to ensure safe work environment and take appropriate action to mitigate potential risks. Employers should therefore assess the hazards of the chemicals used, the potential modes for leakage, means for identifying leaks and the risk of exposure of employees. Ideally, work practices should be developed by healthcare facilities so that sterile processing employees know what to do in case of a chemical leak or spill, and how to safely use these chemicals to ensure their own, and patient safety.

  11. Floating rGO-based black membranes for solar driven sterilization.

    PubMed

    Zhang, Yao; Zhao, Dengwu; Yu, Fan; Yang, Chao; Lou, Jinwei; Liu, Yanming; Chen, Yingying; Wang, Zhongyong; Tao, Peng; Shang, Wen; Wu, Jianbo; Song, Chengyi; Deng, Tao

    2017-12-14

    This paper presents a new steam sterilization approach that uses a solar-driven evaporation system at the water/air interface. Compared to the conventional solar autoclave, this new steam sterilization approach via interfacial evaporation requires no complex system design to bear high steam pressure. In such a system, a reduced graphene oxide/polytetrafluoroethylene composite membrane floating at the water/air interface serves as a light-to-heat conversion medium to harvest and convert incident solar light into localized heat. Such localized heat raises the temperature of the membrane substantially and helps generate steam with a temperature higher than 120 °C. A sterilization device that takes advantage of the interfacial solar-driven evaporation system was built and its successful sterilization capability was demonstrated through both chemical and biological sterilization tests. The interfacial evaporation-based solar driven sterilization approach offers a potential low cost solution to meet the need for sterilization in undeveloped areas that lack electrical power but have ample solar radiation.

  12. 31 CFR 585.419 - Effect of E.O. 12846 on outstanding licenses and authorizations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Effect of E.O. 12846 on outstanding licenses and authorizations. 585.419 Section 585.419 Money and Finance: Treasury Regulations Relating to... AND HERZEGOVINA SANCTIONS REGULATIONS Interpretations § 585.419 Effect of E.O. 12846 on outstanding...

  13. Bactrocera dorsalis male sterilization by targeted RNA interference of spermatogenesis: empowering sterile insect technique programs

    PubMed Central

    Dong, Yong-Cheng; Wang, Zhi-Jian; Chen, Zhen-Zhong; Clarke, Anthony R.; Niu, Chang-Ying

    2016-01-01

    RNA interference (RNAi) is a genetic technique which has novel application for sustainable pest control. The Sterile Insect Technique (SIT) uses releases of mass-produced, sterile male insects to out-compete wild males for mates to reduce pest populations. RNAi sterilization of SIT males would have several advantages over radiation sterilization, but to achieve this appropriate target genes must first be identified and then targeted with interference technology. With this goal, eight spermatogenesis related candidate genes were cloned and tested for potential activity in Bactrocera dorsalis. The knockdown of candidate genes by oral delivery of dsRNAs did not influence the mating of male flies, but significantly affected the daily average number of eggs laid by females, and reduced egg hatching rate by 16–60%. RNAi negatively affected spermatozoa quantitatively and qualitatively. Following the mating of lola-/topi-/rac-/rho-/upd-/magu-silenced males, we recorded a significant decrease in number and length of spermatozoa in female spermatheca compared to gfp-silenced control group. In a greenhouse trial, the number of damaged oranges and B. dorsalis larvae were significantly reduced in a dsrho-treated group compared with the dsgfp group. This study provides strong evidence for the use RNAi in pest management, especially for the improvement of SIT against B. dorsalis and other species. PMID:27767174

  14. Sterile insect technique: A model for dose optimisation for improved sterile insect quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, A.; Mehta, K.

    The sterile insect technique (SIT) is an environment-friendly pest control technique with application in the area-wide integrated control of key pests, including the suppression or elimination of introduced populations and the exclusion of new introductions. Reproductive sterility is normally induced by ionizing radiation, a convenient and consistent method that maintains a reasonable degree of competitiveness in the released insects. The cost and effectiveness of a control program integrating the SIT depend on the balance between sterility and competitiveness, but it appears that current operational programs with an SIT component are not achieving an appropriate balance. In this paper we discussmore » optimization of the sterilization process and present a simple model and procedure for determining the optimum dose. (author) [Spanish] La tecnica de insecto esteril (TIE) es una tecnologia de control de plagas favorable para el medio ambiente con una aplicacion de un control integrado de plagas claves para toda la area, incluyendo la supresion o eliminacion de poblaciones introducidas y la exclusion de nuevas introducciones. La esterilidad reproductiva es normalmente inducida por radiacion ionizada, un metodo conveniente y consistente que mantiene un grado razonable para la capacidad de competencia en insectos liberados. El costo y la eficacia de un programa de control que incluye TIE dependen en tener un balance entre la esterilidad y la capacidad para competir, pero parece que los programas operacionales corrientes con TIS como un componente no estan logrando el tener un balance apropiado. En esta publicacion, nosotros discutimos la optimizacion del proceso de esterilizacion y presentamos un modelo y procedimiento sencillos para determinar la dosis optima. (author)« less

  15. Nitrogen Dioxide Sterilization in Low-Resource Environments: A Feasibility Study

    PubMed Central

    Avasthi, Trisha; Trilling, Ariel

    2015-01-01

    Access to sterilization is a critical need for global healthcare, as it is one of the prerequisites for safe surgical care. Lack of sterilization capability has driven up healthcare infection rates as well as limited access to healthcare, especially in low-resource environments. Sterilization technology has for the most part been static and none of the established sterilization methods has been so far successfully adapted for use in low-resource environments on a large scale. It is evident that healthcare facilities in low-resource settings require reliable, deployable, durable, affordable, easily operable sterilization equipment that can operate independently of scarce resources. Recently commercialized nitrogen dioxide (NO2) sterilization technology was analyzed and adapted into a form factor suitable for use in low-resource environments. Lab testing was conducted in microbiological testing facilities simulating low-resource environments and in accordance with the requirements of the international sterilization standard ANSI/AAMI/ISO 14937 to assess effectiveness of the device and process. The feasibility of a portable sterilizer based on nitrogen dioxide has been demonstrated, showing that sterilization of medical instruments can occur in a form factor suitable for use in low-resource environments. If developed and deployed, NO2 sterilization technology will have the twin benefits of reducing healthcare acquired infections and limiting a major constraint for access to surgical care on a global scale. Additional benefits are achieved in reducing costs and biohazard waste generated by current health care initiatives that rely primarily on disposable kits, increasing the effectiveness and outreach of these initiatives. PMID:26098905

  16. End-preparation assessments and tests for compounded sterile preparations.

    PubMed

    McElhiney, Linda F

    2013-01-01

    Outsourcing has become a necessity to obtain sterile products that are currently on backorder. Because of the expense of outsourcing sterile compounding, pharmacy leadership in health systems are now considering the option of insourcing and batch preparing compounded sterile preparations, which can be a viable option for a health system. It can significantly decrease drug-spending costs, and the pharmacy has a complete record of the compounding process. The key to preparing high-quality, safe, sterile preparations and meeting United States Pharmacopeia standards is end-preparation assessments and tests.

  17. Hybrid male sterility and genome-wide misexpression of male reproductive proteases.

    PubMed

    Gomes, Suzanne; Civetta, Alberto

    2015-07-06

    Hybrid male sterility is a common barrier to gene flow between species. Previous studies have posited a link between misregulation of spermatogenesis genes in interspecies hybrids and sterility. However, in the absence of fully fertile control hybrids, it is impossible to differentiate between misregulation associated with sterility vs. fast male gene regulatory evolution. Here, we differentiate between these two possibilities using a D. pseudoobscura species pair that experiences unidirectional hybrid sterility. We identify genes uniquely misexpressed in sterile hybrid male reproductive tracts via RNA-seq. The sterile male hybrids had more misregulated and more over or under expressed genes relative to parental species than the fertile male hybrids. Proteases were the only gene ontology class overrepresented among uniquely misexpressed genes, with four located within a previously identified hybrid male sterility locus. This result highlights the potential role of a previously unexplored class of genes in interspecific hybrid male sterility and speciation.

  18. Sterility Testing of Prototype Plastic Aseptic Docking Tubes

    DTIC Science & Technology

    1982-09-01

    Bacillus stearothermophilus CL21. AmerRACT (Coat~e- aeids uIf 8" niev teIi by block n"Unbee) Fifty-nine pairs of sterile docking tabs, manufactured...of Bacillus stearothermophilus , _J sealed, and flushed with sterile culture medium. Twenty five percent of the LA_.. seals failed because of...were similarly attached to sterile tubes of Becton Dickenson supplemented peptone broth. A 25 ul aliquot of Bacillus stearothermophilus spores (Ix]O

  19. On the intrinsic sterility of 3D printing

    PubMed Central

    Flynn, Kaitlin J.; Zaman, Luis; Tung, Emily; Pudlo, Nicholas

    2016-01-01

    3D printers that build objects using extruded thermoplastic are quickly becoming commonplace tools in laboratories. We demonstrate that with appropriate handling, these devices are capable of producing sterile components from a non-sterile feedstock of thermoplastic without any treatment after fabrication. The fabrication process itself results in sterilization of the material. The resulting 3D printed components are suitable for a wide variety of applications, including experiments with bacteria and cell culture. PMID:27920950

  20. Evaluation of steam penetration and sterilization of natural latex wraps.

    PubMed

    Rossanese, Matteo; Gasson, James; Barker, Colin; Bowlt, Kelly

    2014-11-01

    To evaluate the efficacy of steam and ethylene oxide (EtO) sterilization of Vetrap™ bandages. Prospective experimental study. Vetrap™ bandages (n = 70; 35 as supplied by the manufacturer, 35 unwound and tightly rewound). Vetrap™ bandage rolls (n = 60) marked with a 1 cm square were inoculated with 0.1 mL Geobacillus stearothermophilus spores, packaged in a pouch together with independent sterilization indicators and assigned into 3 sub-groups for sterilizer type: dynamic air removal, gravity displacement, and bench-top pre-vacuum and further sub-divided into 2 sterilization temperatures. Vetrap™ bandages rolls (n = 10) were inoculated with 0.1 mL Bacillus atrophaeus spores in the same manner and underwent EtO sterilization. After sterilization, the 1 cm marked square was aseptically resected to the level of the cardboard tube and enriched in a flask containing 10 mL tryptic soy broth for 24 hours at 60°C for G. stearothermophilus and 37°C for B. atrophaeus. Aliquots were subsequently plated on a Petri dish of tryptic soy agar and incubated at 60°C for G. stearothermophilus and 37°C for B. atrophaeus for 24 hours. Samples were scored positive if colonies of indicator organism were present on the nutrient agar after 24 hours. Three Vetrap™ bandages yielded post-sterilization growth of G. stearothermophilus: 2 from the dynamic air removal sterilizer at 134°C for 3.5 minutes, and 1 from the bench-top pre-vacuum sterilizer at 121°C for 15 minutes. After EtO sterilization, no positive samples were detected. Steam sterilization may be incomplete for Vetrap™ bandages whereas EtO showed complete destruction of resistant bacterial spores. © Copyright 2014 by The American College of Veterinary Surgeons.

  1. Understanding current steam sterilization recommendations and guidelines.

    PubMed

    Spry, Cynthia

    2008-10-01

    Processing surgical instruments in preparation for surgery is a complex multistep practice. It is impractical to culture each and every item to determine sterility; therefore, the best assurance of a sterile product is careful execution of every step in the process coupled with an ongoing quality control program. Perioperative staff nurses and managers responsible for instrument processing, whether for a single instrument or multiple sets, must be knowledgeable with regard to cleaning; packaging; cycle selection; and the use of physical, chemical, and biological monitors. Nurses also should be able to resolve issues related to loaner sets, flash sterilization, and extended cycles.

  2. Design of the EO-1 Pulsed Plasma Thruster Attitude Control Experiment

    NASA Technical Reports Server (NTRS)

    Zakrzwski, Charles; Sanneman, Paul; Hunt, Teresa; Blackman, Kathie; Bauer, Frank H. (Technical Monitor)

    2001-01-01

    The Pulsed Plasma Thruster (PPT) Experiment on the Earth Observing 1 (EO-1) spacecraft has been designed to demonstrate the capability of a new generation PPT to perform spacecraft attitude control. The PPT is a small, self-contained pulsed electromagnetic Propulsion system capable of delivering high specific impulse (900-1200 s), very small impulse bits (10-1000 micro N-s) at low average power (less than 1 to 100 W). EO-1 has a single PPT that can produce torque in either the positive or negative pitch direction. For the PPT in-flight experiment, the pitch reaction wheel will be replaced by the PPT during nominal EO-1 nadir pointing. A PPT specific proportional-integral-derivative (PID) control algorithm was developed for the experiment. High fidelity simulations of the spacecraft attitude control capability using the PPT were conducted. The simulations, which showed PPT control performance within acceptable mission limits, will be used as the benchmark for on-orbit performance. The flight validation will demonstrate the ability of the PPT to provide precision pointing resolution. response and stability as an attitude control actuator.

  3. Association of Hysteroscopic vs Laparoscopic Sterilization With Procedural, Gynecological, and Medical Outcomes.

    PubMed

    Bouillon, Kim; Bertrand, Marion; Bader, Georges; Lucot, Jean-Philippe; Dray-Spira, Rosemary; Zureik, Mahmoud

    2018-01-23

    Safety of hysteroscopic sterilization has been recently questioned following reports of general symptoms such as allergy, tiredness, and depression in addition to associated gynecological results such as pelvic pain, perforation of fallopian tubes or uterus, and unwanted pregnancy. To compare the risk of reported adverse events between hysteroscopic and laparoscopic sterilization. French nationwide cohort study using the national hospital discharge database linked to the health insurance claims database. Women aged 30 to 54 years receiving a first hysteroscopic or laparoscopic sterilization between 2010 and 2014 were included and were followed up through December 2015. Hysteroscopic sterilization vs laparoscopic sterilization. Risks of procedural complications (surgical and medical) and of gynecological (sterilization failure that includes salpingectomy, second sterilization procedure, or pregnancy; pregnancy; reoperation) and medical outcomes (all types of allergy; autoimmune diseases; thyroid disorder; use of analgesics, antimigraines, antidepressants, benzodiazepines; outpatient visits; sickness absence; suicide attempts; death) that occurred within 1 and 3 years after sterilization were compared using inverse probability of treatment-weighted Cox models. Of the 105 357 women included (95.5% of eligible participants; mean age, 41.3 years [SD, 3.7 years]), 71 303 (67.7% ) underwent hysteroscopic sterilization, and 34 054 (32.3%) underwent laparoscopic sterilization. During the hospitalization for sterilization, risk of surgical complications for hysteroscopic sterilization was lower: 0.13% for hysteroscopic sterilization vs 0.78% for laparoscopic sterilization (adjusted risk difference [RD], -0.64; 95% CI, -0.67 to -0.60) and was lower for medical complications: 0.06% vs 0.11% (adjusted RD, -0.05; 95% CI, -0.08 to -0.01). During the first year after sterilization, 4.83% of women who underwent hysteroscopic sterilization had a higher risk of sterilization

  4. 44 CFR Appendix A to Part 9 - Decision-making Process for E.O. 11988

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Decision-making Process for E.O. 11988 A Appendix A to Part 9 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT..., App. A Appendix A to Part 9—Decision-making Process for E.O. 11988 EC02FE91.074 ...

  5. Technology forecasting for space communication. Task one report: Cost and weight tradeoff studies for EOS and TDRS

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Weight and cost optimized EOS communication links are determined for 2.25, 7.25, 14.5, 21, and 60 GHz systems and for a 10.6 micron homodyne detection laser system. EOS to ground links are examined for 556, 834, and 1112 km EOS orbits, with ground terminals at the Network Test and Tracking Facility and at Goldstone. Optimized 21 GHz and 10.6 micron links are also examined. For the EOS to Tracking and Data Relay Satellite to ground link, signal-to-noise ratios of the uplink and downlink are also optimized for minimum overall cost or spaceborne weight. Finally, the optimized 21 GHz EOS to ground link is determined for various precipitation rates. All system performance parameters and mission dependent constraints are presented, as are the system cost and weight functional dependencies. The features and capabilities of the computer program to perform the foregoing analyses are described.

  6. Earth Observing System/Meteorological Satellite (EOS/METSAT). Advanced Microwave Sounding Unit-A (AMSU-A) Contamination Control Plan

    NASA Technical Reports Server (NTRS)

    Fay, M.

    1998-01-01

    This Contamination Control Plan is submitted in response the Contract Document requirements List (CDRL) 007 under contract NAS5-32314 for the Earth Observing System (EOS) Advanced Microwave Sounding Unit A (AMSU-A). In response to the CDRL instructions, this document defines the level of cleanliness and methods/procedures to be followed to achieve adequate cleanliness/contamination control, and defines the required approach to maintain cleanliness/contamination control through shipping, observatory integration, test, and flight. This plan is also applicable to the Meteorological Satellite (METSAT) except where requirements are identified as EOS-specific. This plan is based on two key factors: a. The EOS/METSAT AMSU-A Instruments are not highly contamination sensitive. b. Potential contamination of other EOS Instruments is a key concern as addressed in Section 9/0 of the Performance Assurance Requirements for EOS/METSAT Integrated Programs AMSU-A Instrument (MR) (NASA Specification S-480-79).

  7. Orthodontic instrument sterilization with microwave irradiation

    PubMed Central

    Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram

    2015-01-01

    Objective: This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. Materials and Methods: The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups – Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. Results: No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Conclusion: Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min. PMID:26015686

  8. Doppler lidar wind measurement on Eos

    NASA Technical Reports Server (NTRS)

    Fitzjarrald, D.; Bilbro, J.; Beranek, R.; Mabry, J.

    1985-01-01

    A polar-orbiting platform segment of the Earth Observing System (EOS) could carry a CO2-laser based Doppler lidar for recording global wind profiles. Development goals would include the manufacture of a 10 J laser with a 2 yr operational life, space-rating the optics and associated software, and the definition of models for global aerosol distributions. Techniques will be needed for optimal scanning and generating computer simulations which will provide adequately accurate weather predictions.

  9. Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test.

    PubMed

    Freitas, Raphael Ribeiro de Aquino; Tardelli, Maria Angela

    2016-05-24

    To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. G1 and G2 showed no bacterial growth when compared to conventional groups (p<0.001). The most common agent in conventional microbiological samples was Staphylococcus aureus. There was no fungal growth in both groups. The use of (sterile pack) reduces the microbial load of bottles, and would decrease the chance of exposure to potential contamination of the anesthetic solution. Comparar a esterilidade e a carga microbiana (bactérias e fungos) da parte externa dos frascos de envasamento de bupivacaína hiperbárica (Neocaína®) em ampola e bupivacaína em frasco-ampola das apresentações convencional e estéril (sterile pack). As apresentações estéreis (sterile pack) foram distribuídas em dois grupos, sendo que o G1 (n=16) continha as ampolas e o G2 (n=16), os frascos-ampola. As apresentações convencionais foram distribuídas em dois grupos, a saber G3 (n=16) com as ampolas e G4 (n=16) com os frascos-ampola. As ampolas e os frascos-ampolas eram abertos e tinham seu conteúdo aspirado. Os frascos vazios eram, então, acondicionados em sacos plásticos estéreis e enviados para análise quanto à carga microbiana (bactérias e fungos), bem como para o teste de esterilidade. Os dados foram analisados por meio do teste χ2 com correção Yates com intervalo de confian

  10. [Characteristics and follow-up of sterilized women].

    PubMed

    Molina, R; López, I

    1982-02-01

    In order to gain insight into the characteristics of sterilized women evaluating at the same time the effects of sterilization, 70 patients who underwent sterilization in an Obstetrics Unit were studied. The clinical records were analyzed and a questionnaire comprising general knowledge, attitudes, and conduct was applied. Women over 30 and with a parity of 4 or more predominated. There was a low frequency of abortions reported but this information is not reliable. The educational level was lower than the average for the Metropolitan Region and pointed to a more precocious initiation in sexual relationships than was found in a previous similar study. Religion proved to be no obstacle for sterilization nor was attendance to church subsequently diminished. A negative moral feeling towards the operation nearly disappeared following surgery. The fear of sexual dissatisfaction in husbands decreased following surgery and a similar effect was seen with regard to negative self-image. There were no changes in marital relations nor in their satisfaction. (author's modified)

  11. Quarter of a century of female sterilization in Jos, Central Nigeria.

    PubMed

    Mutihir, Josiah T; Nyango, D D

    2011-03-01

    The study was to assess the types and trend of female sterilization between January 1985 and December 2009 (25 years) in Jos, Central Nigeria. There were 25,313 new acceptors of modern contraceptive methods out of which 4,951 (19.6%) were female sterilizations. Minilaparotomy was the commonest method of female sterilization. Local anaesthesia was the commonest anaesthetic utilized. The women were mostly women of relatively older age, grandmultiparous and with large family size. The women were of mean of 38.4 years, and 60% had more than 5 children at the time of sterilization. Interval sterilization constituted 78.5% of the female sterilizations. The acceptance of female sterilization, however, has declined over the years, as acceptance of the long acting contraceptive implants increases. Female sterilization by minilaparotomy under local anaesthesia was found to be feasible, cost effective and acceptable by majority of clients, and recommended for integration into minor gynaecological procedures in our institutions.

  12. Hybrid male sterility and genome-wide misexpression of male reproductive proteases

    PubMed Central

    Gomes, Suzanne; Civetta, Alberto

    2015-01-01

    Hybrid male sterility is a common barrier to gene flow between species. Previous studies have posited a link between misregulation of spermatogenesis genes in interspecies hybrids and sterility. However, in the absence of fully fertile control hybrids, it is impossible to differentiate between misregulation associated with sterility vs. fast male gene regulatory evolution. Here, we differentiate between these two possibilities using a D. pseudoobscura species pair that experiences unidirectional hybrid sterility. We identify genes uniquely misexpressed in sterile hybrid male reproductive tracts via RNA-seq. The sterile male hybrids had more misregulated and more over or under expressed genes relative to parental species than the fertile male hybrids. Proteases were the only gene ontology class overrepresented among uniquely misexpressed genes, with four located within a previously identified hybrid male sterility locus. This result highlights the potential role of a previously unexplored class of genes in interspecific hybrid male sterility and speciation. PMID:26146165

  13. Current Status of the LOFAR EoR Key Science Project

    NASA Astrophysics Data System (ADS)

    Koopmans, L. V. E.; LOFAR EoR KSP Team

    2018-05-01

    A short status update on the LOFAR Epoch of Reionization (EoR) Key Science Project (KSP) is given, regarding data acquisition, data processing and analysis, and current power-spectrum limits on the redshifted 21-cm signal of neutral hydrogen at redshifts z = 8 - 10. With caution, we present a preliminary astrophysical analysis of ~60 hr of processed LOFAR data and their resulting power spectrum, showing that potentially already interesting limits on X-ray heating during the Cosmic Dawn can already be gained. This is by no means the final analysis of this sub-set of data, but illustrates the future potential when all nearly 3000 hr of data in hand on two EoR windows will have been processed.

  14. SU-E-I-15: Comparison of Radiation Dose for Radiography and EOS in Adolescent Scoliosis Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schueler, B; Walz-Flannigan, A

    Purpose: To estimate patient radiation dose for whole spine imaging using EOS, a new biplanar slot-scanning radiographic system and compare with standard scoliosis radiography. Methods: The EOS imaging system (EOS Imaging, Paris, France) consists of two orthogonal x-ray fan beams which simultaneously acquire frontal and lateral projection images of a standing patient. The patient entrance skin air kerma was measured for each projection image using manufacturer-recommended exposure parameters for spine imaging. Organ and effective doses were estimated using a commercially-available Monte Carlo simulation program (PCXMC, STUK, Radiation and Nuclear Safety Authority, Helsinki, Finland) for a 15 year old mathematical phantommore » model. These results were compared to organ and effective dose estimated for scoliosis radiography using computed radiography (CR) with standard exposure parameters obtained from a survey of pediatric radiographic projections. Results: The entrance skin air kerma for EOS was found to be 0.18 mGy and 0.33 mGy for posterior-anterior (PA) and lateral projections, respectively. This compares to 0.76 mGy and 1.4 mGy for CR, PA and lateral projections. Effective dose for EOS (PA and lateral projections combined) is 0.19 mSv compared to 0.51 mSv for CR. Conclusion: The EOS slot-scanning radiographic system allows for reduced patient radiation dose in scoliosis patients as compared to standard CR radiography.« less

  15. Reliability of Laparoscopic Compared With Hysteroscopic Sterilization at One Year: A Decision Analysis

    PubMed Central

    Gariepy, Aileen M.; Creinin, Mitchell D.; Schwarz, Eleanor B.; Smith, Kenneth J.

    2011-01-01

    OBJECTIVE To estimate the probability of successful sterilization after hysteroscopic or laparoscopic sterilization procedure. METHODS An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. RESULTS In the base case analysis, the proportion of women having a successful sterilization procedure on first attempt is 99% for laparoscopic, 88% for hysteroscopic in the operating room and 87% for hysteroscopic in the office. The probability of having a successful sterilization procedure within one year is 99% with laparoscopic, 95% for hysteroscopic in the operating room, and 94% for hysteroscopic in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. CONCLUSIONS Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within one year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization. PMID:21775842

  16. 75 FR 63823 - Final Guidance, “Federal Greenhouse Gas Accounting and Reporting”

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-18

    ..., 2009. The purpose of the Executive Order is to establish an integrated strategy toward sustainability... Federal agencies. Among other provisions, E.O. 13514 requires agencies to measure, report, and reduce.../sustainability/fed-ghg . DATES: The Final Guidance, ``Federal Greenhouse Gas Accounting and Reporting'' is...

  17. Sterile Neutrino Search with MINOS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devan, Alena V.

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact asmore » a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm 2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, m s 2 ~ 1 eV 2. The results of the 2013 sterile neutrino search are presented here.« less

  18. Sterile neutrinos and RK

    NASA Astrophysics Data System (ADS)

    Vicente, A.

    2013-07-01

    We consider an enhancement in the violation of lepton flavour universality in light meson decays arising from modified Wlν couplings in the standard model minimally extended by sterile neutrinos. Due to the presence of additional mixings between the active neutrinos and the new sterile states, the deviation from unitarity of the leptonic mixing matrix intervening in charged currents might lead to a tree-level enhancement of RP = Γ(P → ev)/Γ(P → μν), with P = K, π. These enhancements are illustrated in the case of the inverse seesaw, showing that one can saturate the current experimental bounds on ΔrK (and Δrπ), while in agreement with the different experimental and observational constraints.

  19. Effects of gamma-sterilization on the physicochemical properties of natural sediments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bank, Tracy L; Madden, Andrew; Baldwin, Mark E

    2008-06-01

    Batch U(VI) sorption/reduction experiments were completed on sterilized and non-sterilized sediment samples to elucidate biological and geochemical reduction mechanisms. Results from X-ray absorption near-edge structure (XANES) spectroscopy revealed that {gamma}-sterilized sediments were actually better sorbents of U(VI), despite the absence of any measurable biological activity. These results indicate that {gamma}-irradiation induced significant physico-chemical changes in the sediment which is contrary to numerous other studies identifying {gamma}-sterilization as an effective and minimally invasive technique. To identify the extent and method of alteration of the soil as a result of {gamma}-sterilization, untreated soil samples, physically separated size fractions, and chemically extracted fractionsmore » of the soil were analyzed pre- and post-sterilization. The effects of sterilization on mineralogy, pH, natural organic matter (NOM), cation exchange capacity (CEC), and iron oxidation state were determined. Results indicated that major mineralogy of the clay and whole sediment samples was unchanged. Sediment pH decreased only slightly with {gamma}-irradiation; however, irradiation produced a significant decrease in CEC of the untreated sediments and affected both the organic and inorganic fractions. Moessbauer spectra of non-sterile and {gamma}-sterilized sediments measured more reduced iron present in {gamma}-sterilized sediments compared to non-sterile samples. Our results suggest that sterilization by {gamma}-irradiation induced iron reduction that may have increased the sorption and/or reduction of U(VI) onto these sediments. However, Moessbauer and batch sorption data are somewhat contradictory, the former indicates that the iron oxide or iron hydroxide minerals are more significantly reduced while the later indicates that reduced clay minerals account for greater sorption of U(VI).« less

  20. Using EO-1 Hyperion Images to Prototype Environmental Products for Hyspiri

    NASA Technical Reports Server (NTRS)

    Middleton, Elizabeth M.; Campbell, Petya K. E.; Ungar, Stephen G.; Ong, Lawrence; Zhang, Qingyuan; Huemmrich, K. Fred; Mandl, Daniel J.; Frye, Stuart W.

    2011-01-01

    In November 2010, the Earth Observing One (EO-1) Satellite Mission will successfully complete a decade of Earth imaging by its two unique instruments, the Hyperion and the Advanced Land Imager (ALI). Both instruments are serving as prototypes for new orbital sensors, and the EO-1 is a heritage platform for the upcoming German mission, EnMAP. We provide an overview of the mission's lifetime. We briefly describe calibration & validation activities and overview the technical and scientific accomplishments of this mission. Some examples of the Mission Science Office (MSO) products are provided, as is an example of a image collected for disaster monitoring.

  1. Hospital steam sterilizer usage: could we switch off to save electricity and water?

    PubMed

    McGain, Forbes; Moore, Graham; Black, Jim

    2016-07-01

    Steam sterilization in hospitals is an energy and water intensive process. Our aim was to identify opportunities to improve electricity and water use. The objectives were to find: the time sterilizers spent active, idle and off; the variability in sterilizer use with the time of day and day of the week; and opportunities to switch off sterilizers instead of idling when no loads were waiting, and the resultant electricity and water savings. Analyses of routine data for one year of the activity of the four steam sterilizers in one hospital in Melbourne, Australia. We examined active sterilizer cycles, routine sterilizer switch-offs, and when sterilizers were active, idle and off. Several switch-off strategies were examined to identify electricity and water savings: switch off idle sterilizers when no loads are waiting and switch off one sterilizer after 10:00 h and a second sterilizer after midnight on all days. Sterilizers were active for 13,430 (38%) sterilizer-hours, off for 4822 (14%) sterilizer-hours, and idle for 16,788 (48%) sterilizer-hours. All four sterilizers were simultaneously active 9% of the time, and two or more sterilizers were idle for 69% of the time. A sterilizer was idle for two hours or less 13% of the time and idle for more than 2 h 87% of the time. A strategy to switch off idle sterilizers would reduce electricity use by 66 MWh and water use by 1004 kl per year, saving 26% electricity use and 13% of water use, resulting in financial savings of AUD$13,867 (UK£6,517) and a reduction in 79 tonnes of CO2 emissions per year. An alternative switch-off strategy of one sterilizer from 10:00 h onwards and a second from midnight would have saved 30 MWh and 456 kl of water. The methodology used of how hospital sterilizer use could be improved could be applied to all hospitals and more broadly to other equipment used in hospitals. © The Author(s) 2016.

  2. About the Sterilization of Chitosan Hydrogel Nanoparticles

    PubMed Central

    Galante, Raquel; Rediguieri, Carolina F.; Kikuchi, Irene Satiko; Vasquez, Pablo A. S.; Colaço, Rogério; Pinto, Terezinha J. A.

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles. PMID:28002493

  3. Reason behind wet pack after steam sterilization and its consequences: An overview from Central Sterile Supply Department of a cancer center in eastern India.

    PubMed

    Basu, Debabrata

    Wet pack after steam sterilization process that means there are surely obtain millions of microorganisms that can breed and multiply rapidly and objects are unsterile and can never be used for further procedure. There are many reasons behind the wet pack occurrences after autoclaving like poor quality of wrapping materials, faulty valves of rigid container, faulty loading and packaging technique, poor steam quality, sterilizer malfunction and may be design related problems in CSSD sterile storage area. Cause of wet pack after steam sterilization processes may occur severe problems because of wasted time and effort, increased work load, increased cost, potentially contaminated instruments, infection risk to the patient, poor patient outcomes and delayed or cancellation of procedures. But such wet pack scenario can be avoided by various methods by using good steam (water) quality, performing periodic maintenance of the Autoclaves, avoidance of sterilizer overloading, allowing adequate post sterilization time to cool down the materials to room temperature, using good quality wrapping materials, properly maintain temperature and humidity of sterile storage area etc. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  4. Earth Observing System (EOS) Aqua Launch and Early Mission Attitude Support Experiences

    NASA Technical Reports Server (NTRS)

    Tracewell, D.; Glickman, J.; Hashmall, J.; Natanson, G.; Sedlak, J.

    2003-01-01

    The Earth Observing System (EOS) Aqua satellite was successfully launched on May 4,2002. Aqua is the second in the series of EOS satellites. EOS is part of NASA s Earth Science Enterprise Program, whose goals are to advance the scientific understanding of the Earth system. Aqua is a three-axis stabilized, Earth-pointing spacecraft in a nearly circular, sun-synchronous orbit at an altitude of 705 km. The Goddard Space Flight Center (GSFC) Flight Dynamics attitude team supported all phases of the launch and early mission. This paper presents the main results and lessons learned during this period, including: real-time attitude mode transition support, sensor calibration, onboard computer attitude validation, response to spacecraft emergencies, postlaunch attitude analyses, and anomaly resolution. In particular, Flight Dynamics support proved to be invaluable for successful Earth acquisition, fine-point mode transition, and recognition and correction of several anomalies, including support for the resolution of problems observed with the MODIS instrument.

  5. Insights on How NASA's Earth Observing System (EOS) Monitors Our World Environment

    NASA Technical Reports Server (NTRS)

    King, Michael D.

    2000-01-01

    The Earth Observing System (EOS) is a space-based observing system comprised of a series of satellite sensors by which scientists can monitor the Earth, a Data and Information System (EOSDIS) enabling researchers worldwide to access the satellite data, and an interdisciplinary science research program to interpret the satellite data. During this year, four EOS science missions were launched, representing observations of (1) total solar irradiance, (2) Earth radiation budget, (3) land cover and land use change, (4) ocean processes (vector wind, sea surface temperature, and ocean color), (5) atmospheric processes (aerosol and cloud properties, water vapor, and temperature and moisture profiles), and (6) tropospheric chemistry. In succeeding years many more satellites will be launched that will contribute immeasurably to our understanding of the Earth's environment. In this presentation I will describe how scientists are using EOS data to examine land use and natural hazards, environmental air quality, including dust storms over the world's deserts, cloud and radiation properties, sea surface temperature, and winds over the ocean.

  6. Comparative Analysis of Dibutyric cAMP and Butyric Acid on the Differentiation of Human Eosinophilic Leukemia EoL-1 Cells.

    PubMed

    Jung, YunJae

    2015-12-01

    Purification of enough numbers of circulating eosinophils is difficult because eosinophils account for less than 5% peripheral blood leukocytes. Human eosinophilic leukemia EoL-1 cells have been considered an in vitro source of eosinophils as they can differentiate into mature eosinophil-like cells when incubated with dibutyryl cAMP (dbcAMP) or butyric acid. In this study, the viability and phenotypic maturation of EoL-1 cells stimulated by either dbcAMP or butyric acid were comparatively analyzed. After treatment with 100 µM dbcAMP or 0.5 µM butyric acid, EoL-1 cells showed morphological signs of differentiation, although the number of nonviable EoL-1 cells was significantly increased following butyric acid treatment. Stimulation of EoL-1 cells with 0.5 µM butyric acid more effectively induced the expression of mature eosinophil markers than stimulation with dbcAMP. These results suggest that treatment of EoL-1 cells with 0.5 µM butyric acid for limited duration could be an effective strategy for inducing their differentiation. Considering that expression of CCR3 was not sufficient in EoL-1 cells stimulated with 0.5 µM butyric acid, treatment of the chemically stimulated EoL-1 cells with cytokines, which primarily support eosinophil maturation, would help to obtain differentiated EoL-1 cells with greater functional maturity.

  7. Comparative Analysis of Dibutyric cAMP and Butyric Acid on the Differentiation of Human Eosinophilic Leukemia EoL-1 Cells

    PubMed Central

    2015-01-01

    Purification of enough numbers of circulating eosinophils is difficult because eosinophils account for less than 5% peripheral blood leukocytes. Human eosinophilic leukemia EoL-1 cells have been considered an in vitro source of eosinophils as they can differentiate into mature eosinophil-like cells when incubated with dibutyryl cAMP (dbcAMP) or butyric acid. In this study, the viability and phenotypic maturation of EoL-1 cells stimulated by either dbcAMP or butyric acid were comparatively analyzed. After treatment with 100 µM dbcAMP or 0.5 µM butyric acid, EoL-1 cells showed morphological signs of differentiation, although the number of nonviable EoL-1 cells was significantly increased following butyric acid treatment. Stimulation of EoL-1 cells with 0.5 µM butyric acid more effectively induced the expression of mature eosinophil markers than stimulation with dbcAMP. These results suggest that treatment of EoL-1 cells with 0.5 µM butyric acid for limited duration could be an effective strategy for inducing their differentiation. Considering that expression of CCR3 was not sufficient in EoL-1 cells stimulated with 0.5 µM butyric acid, treatment of the chemically stimulated EoL-1 cells with cytokines, which primarily support eosinophil maturation, would help to obtain differentiated EoL-1 cells with greater functional maturity. PMID:26770185

  8. Earth Observing System/Advanced Microwave SoundingUnit-A (EOS/AMSU-A): Acquisition activities plan

    NASA Technical Reports Server (NTRS)

    Schwantje, Robert

    1994-01-01

    This is the acquisition activities plan for the software to be used in the Earth Observing System (EOS) Advanced Microwave Sounding Unit-A (AMSU-A) system. This document is submitted in response to Contract NAS5-323 14 as CDRL 508. The procurement activities required to acquire software for the EOS/AMSU-A program are defined.

  9. Use of EOS Low-Dose Biplanar X-Ray for Shunt Series in Children with Hydrocephalus: A Preliminary Study.

    PubMed

    Ben-Sira, Liat; Shiran, Shelly I; Pratt, Li-Tal; Precel, Ronit; Ovadia, Dror; Constantini, Shlomi; Roth, Jonathan

    2018-05-04

    Shunt series (SS) are a common diagnostic tool used to verify shunt integrity. SS include X-ray films of the skull, chest, and abdomen and often are performed either when a shunted patient presents with suspected shunt malfunction or as a screening test to identify shunt disconnections or dislodgment. EOS low-dose biplanar X-rays are associated with significantly reduced radiation doses compared with ordinary X-rays and are used for various indications. This is the first publication on the use of EOS as a SS technique. Over a period of 6 months, EOS were performed at our center for various orthopedic indications, mostly for scoliosis evaluation. Nine children (<20 years of age) had a ventriculoperitoneal shunt and served as the study group. We retrospectively reviewed shunt visibility and integrity in the EOS scans as well as regular SS or plain spinal X-rays. Three patients had bilateral shunts, and 8 had previous X-rays for comparison. In all patients, the shunt integrity was easily demonstrated on the EOS images. Two patients had an identified shunt disconnection confirmed on the EOS images. No shunt-related information was missed on the EOS compared with the other X-ray images. These preliminary results suggest that EOS may be used as an alternative technology to demonstrate shunt integrity instead of regular X-ray SS. Favorable shunt visibility without the need for multiple radiation exposures and image processing (such as stitching) results in a significantly shorter examination time and significant less radiation. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Sterilization process indicator. 880.2800 Section 880.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... resistance to the mode of sterilization, in or on a carrier and enclosed in a protective package. Subsequent...

  11. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization process indicator. 880.2800 Section 880.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... resistance to the mode of sterilization, in or on a carrier and enclosed in a protective package. Subsequent...

  12. Tubal anastomosis after previous sterilization: a systematic review.

    PubMed

    van Seeters, Jacoba A H; Chua, Su Jen; Mol, Ben W J; Koks, Carolien A M

    2017-05-01

    Female sterilization is one of the most common contraceptive methods. A small number of women, however, opt for reversal of sterilization procedures after they experience regret. Procedures can be performed by laparotomy or laparoscopy, with or without robotic assistance. Another commonly utilized alternative is IVF. The choice between surgery and IVF is often influenced by reimbursement politics for that particular geographic location. We evaluated the fertility outcomes of different surgical methods available for the reversal of female sterilization, compared these to IVF and assessed the prognostic factors for success. Two search strategies were employed. Firstly, we searched for randomized and non-randomized clinical studies presenting fertility outcomes of sterilization reversal up to July 2016. Data on the following outcomes were collected: pregnancy rate, ectopic pregnancy rate, cost of the procedure and operative time. Eligible study designs included prospective or retrospective studies, randomized controlled trials, cohort studies, case-control studies and case series. No age restriction was applied. Exclusion criteria were patients suffering from tubal infertility from any other reason (e.g. infection, endometriosis and adhesions from previous surgery) and studies including <10 participants. The following factors likely to influence the success of sterilization reversal procedures were then evaluated: female age, BMI and duration and method of sterilization. Secondly, we searched for randomized and non-randomized clinical studies that compared reversal of sterilization to IVF and evaluated them for pregnancy outcomes and cost effectiveness. We included 37 studies that investigated a total of 10 689 women. No randomized controlled trials were found. Most studies were retrospective cohort studies of a moderate quality. The pooled pregnancy rate after sterilization reversal was 42-69%, with heterogeneity seen from the different methods utilized. The reported

  13. Search for sterile neutrinos with the SOX experiment

    NASA Astrophysics Data System (ADS)

    Caminata, A.; Agostini, M.; Altenmüller, K.; Appel, S.; Bellini, G.; Benziger, J.; Berton, N.; Bick, D.; Bonfini, G.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Cavalcante, P.; Chepurnov, A.; Choi, K.; Cribier, M.; D'Angelo, D.; Davini, S.; Derbin, A.; Di Noto, L.; Drachnev, I.; Durero, M.; Empl, A.; Etenko, A.; Farinon, S.; Fischer, V.; Fomenko, K.; Franco, D.; Gabriele, F.; Gaffiot, J.; Galbiati, C.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Houdy, Th.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jonquères, N.; Jedrzejczak, K.; Kaiser, M.; Kobychev, V.; Korablev, D.; Korga, G.; Kornoukhov, V.; Kryn, D.; Lachenmaier, T.; Lasserre, T.; Laubenstein, M.; Lehnert, B.; Link, J.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Manecki, S.; Maneschg, W.; Marcocci, S.; Maricic, J.; Mention, G.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Montuschi, M.; Mosteiro, P.; Muratova, V.; Musenich, R.; Neumair, B.; Oberauer, L.; Obolensky, M.; Ortica, F.; Otis, K.; Pagani, L.; Pallavicini, M.; Papp, L.; Perasso, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Romani, A.; Roncin, R.; Rossi, N.; Schönert, S.; Scola, L.; Semenov, D.; Simgen, H.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Sukhotin, S.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Unzhakov, E.; Veyssière, C.; Vivier, M.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.

    2016-01-01

    In the recent years, the Borexino detector has proven its outstanding performances in detecting neutrinos and antineutrinos in the low energy regime. Consequently, it is an ideal tool to investigate the existence of sterile neutrinos, whose presence has been suggested by several anomalies over the past two decades. The SOX ( Short distance neutrino Oscillations with boreXino) project will investigate the presence of sterile neutrinos placing a neutrino and an antineutrino sources in a location under the detector foreseen for this purpose since the construction of Borexino. Interacting in the detector active volume, each beam would create a well detectable spatial wave pattern in case of oscillation of neutrino or antineutrino in a sterile state. Otherwise, the experiment will set a very stringent limit on the existence of a sterile state.

  14. Tactical EO/IE System for Ground Forces

    DTIC Science & Technology

    1990-09-01

    this thesis is based on these ideas. We will give the guidelines to a project manager or to a beginner in EW research about EO/IR system acquisition...1982 Syria vs Israel Syria: 1 Syria 5+ By Syria: 89 by 96+ Sparrow AIM-9G/L PYTHON Korea: 1 B- Kamchatka 1983 Korea vs USSR 0 0 747(KAL-(07) by AA-3 or

  15. Autonomous Science on the EO-1 Mission

    NASA Technical Reports Server (NTRS)

    Chien, S.; Sherwood, R.; Tran, D.; Castano, R.; Cichy, B.; Davies, A.; Rabideau, G.; Tang, N.; Burl, M.; Mandl, D.; hide

    2003-01-01

    In mid-2003, we will fly software to detect science events that will drive autonomous scene selectionon board the New Millennium Earth Observing 1 (EO-1) spacecraft. This software will demonstrate the potential for future space missions to use onboard decision-making to detect science events and respond autonomously to capture short-lived science events and to downlink only the highest value science data.

  16. Optical and application study of gas-liquid discharge excited by bipolar nanosecond pulse in atmospheric air.

    PubMed

    Wang, Sen; Wang, Wen-chun; Yang, De-zheng; Liu, Zhi-jie; Zhang, Shuai

    2014-10-15

    In this study, a bipolar nanosecond pulse with 20ns rising time is employed to generate air gas-liquid diffuse discharge plasma with room gas temperature in quartz tube at atmospheric pressure. The image of the discharge and optical emission spectra of active species in the plasma are recorded. The plasma gas temperature is determined to be approximately 390K by compared the experimental spectra with the simulated spectra, which is slightly higher than the room temperature. The result indicated that the gas temperature rises gradually with pulse peak voltage increasing, while decreases slightly with the electrode gap distance increasing. As an important application, bipolar nanosecond pulse discharge is used to sterilize the common microorganisms (Actinomycetes, Candida albicans and Escherichia coli) existing in drinking water, which performs high sterilization efficiency. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Efficacy of air/water syringe tip sterilization.

    PubMed

    Inger, M; Bennani, V; Farella, M; Bennani, F; Cannon, R D

    2014-03-01

    Dental procedures involve contact between instruments and the patient's tissues, blood or saliva. This study evaluated the efficacy of the standardized sterilization of non-disposable air/water syringe tips and corrosion and contaminant build-up in these tips. The bacterial contamination of single-use and multiple-use non-disposable air/water syringe tips after routine use and sterilization was compared to that of single-use disposable tips by microbial culturing on PCA and blood agar plates. The effect of flushing the syringe tips prior to sterilization was also measured. The amount of corrosion in single-use and multiple-use non-disposable syringes was measured by SEM and EDS analyses. Non-disposable syringe tips had significantly (p < 0.05) greater bacterial contamination than single-use disposable tips. There were no statistically different levels of contamination between flushed and non-flushed non-disposable syringes or between single-use and multiple-use non-disposable syringes. SEM and EDS analyses showed greater evidence of corrosion and contaminant build-up in multiple-use syringes compared to single-use non-disposable syringes. Sterilization of non-disposable air/water syringes is not completely effective and rinsing, or the number of uses, does not affect the effectiveness of sterilization. There may be a lower risk of cross-infection from the use of disposable air/water syringe tips, instead of non-disposable ones. © 2014 Australian Dental Association.

  18. Science Requirements Document for OMI-EOS. 2

    NASA Technical Reports Server (NTRS)

    Bhartia, P. K.; Chance, K.; Isaksen, I.; Levelt, P. F.; Boersma, F.; Brinksma, E.; Carpay, J.; vanderA, R.; deHaan, J.; Hilsenrath, E.

    2000-01-01

    A Dutch-Finnish scientific and industrial consortium is supplying the Ozone Monitoring Instrument (OMI) for Earth Observing System-Aura (EOS-Aura). EOS-Aura is the next NASA mission to study the Earth's atmosphere extensively, and successor to the highly successful UARS (Upper Atmospheric Research Satellite) mission. The 'Science Requirements Document for OMI-EOS' presents an overview of the Aura and OMI mission objectives. It describes how OMI fits into the Aura mission and it reviews the synergy with the other instruments onboard Aura to fulfill the mission. This evolves in the Scientific Requirements for OMI (Chapter 3), stating which trace gases have to be measured with what necessary accuracy, in order for OMI to meet Aura's objectives. The most important data product of OMI, the ozone vertical column, densities shall have a better accuracy and an improved global coverage than the predecessor instruments TOMS (Total Ozone Monitoring Spectrometer) and GOME (Global Ozone Monitoring Experiment), which is a.o. achieved by a better signal to noise ratio, improved calibration and a wide field-of-view. Moreover, in order to meet its role on Aura, OMI shall measure trace gases, such as NO2, OClO, BrO, HCHO and SO2, aerosols, cloud top height and cloud coverage. Improved accuracy, better coverage, and finer ground grid than has been done in the past are goals for OMI. After the scientific requirements are defined, three sets of subordinate requirements are derived. These are: the algorithm requirements, i.e. what do the algorithms need in order to meet the scientific requirements; the instrument and calibration requirements, i.e. what has to be measured and how accurately in order to provide the quality of data necessary for deriving the data products; and the validation requirements, i.e. a strategy of how the OMI program will assure that its data products are valid in the atmosphere, at least to the required accuracy.

  19. Splint sterilization--a potential registration hazard in computer-assisted surgery.

    PubMed

    Figl, Michael; Weber, Christoph; Assadian, Ojan; Toma, Cyril D; Traxler, Hannes; Seemann, Rudolf; Guevara-Rojas, Godoberto; Pöschl, Wolfgang P; Ewers, Rolf; Schicho, Kurt

    2012-04-01

    Registration of preoperative targeting information for the intraoperative situation is a crucial step in computer-assisted surgical interventions. Point-to-point registration using acrylic splints is among the most frequently used procedures. There are, however, no generally accepted recommendations for sterilization of the splint. An appropriate method for the thermolabile splint would be hydrogen peroxide-based plasma sterilization. This study evaluated the potential deformation of the splint undergoing such sterilization. Deformation was quantified using image-processing methods applied to computed tomographic (CT) volumes before and after sterilization. An acrylic navigation splint was used as the study object. Eight metallic markers placed in the splint were used for registration. Six steel spheres in the mouthpiece were used as targets. Two CT volumes of the splint were acquired before and after 5 sterilization cycles using a hydrogen peroxide sterilizer. Point-to-point registration was applied, and fiducial and target registration errors were computed. Surfaces were extracted from CT scans and Hausdorff distances were derived. Effectiveness of sterilization was determined using Geobacillus stearothermophilus. Fiducial-based registration of CT scans before and after sterilization resulted in a mean fiducial registration error of 0.74 mm; the target registration error in the mouthpiece was 0.15 mm. The Hausdorff distance, describing the maximal deformation of the splint, was 2.51 mm. Ninety percent of point-surface distances were shorter than 0.61 mm, and 95% were shorter than 0.73 mm. No bacterial growth was found after the sterilization process. Hydrogen peroxide-based low-temperature plasma sterilization does not deform the splint, which is the base for correct computer-navigated surgery. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Risks and Benefits of Salpingectomy at the Time of Sterilization.

    PubMed

    Castellano, Tara; Zerden, Matthew; Marsh, Laura; Boggess, Kim

    2017-11-01

    Bilateral salpingectomy reduces the risk ovarian cancer. The Society of Gynecologic Oncology has recommended surgeons discuss salpingectomy with patients desiring sterilization. This review summarizes current literature on the benefits and risks of bilateral salpingectomy to reduce ovarian cancer risk. Areas of insufficient evidence and directions for further research are discussed. We examined the benefits and risks of bilateral salpingectomy for female surgical sterilization, using a PubMed and EMBASE literature review. Search parameters included articles in English language and keywords "salpingectomy" or "ovarian cancer" combined with "contraception," "sterilization," or "tubal ligation." We reviewed 4 high-quality studies that investigated the increased risk reduction of bilateral salpingectomy compared with traditional sterilization. Overall, evidence shows that salpingectomy moderately decreases the risk of ovarian cancer compared with traditional sterilization. An additional 4 studies, including a meta-analysis, showed salpingectomy likely does not have significant long-term impact on ovarian reserve. Additional benefits include improved contraceptive efficacy and elimination of subsequent ectopic pregnancies. Risks include need for in vitro fertilization for patients experiencing sterilization regret, increases in operative time, and potential increases in surgical risks. Bilateral salpingectomy can reduce ovarian cancer risk compared with traditional sterilization; however, research regarding other outcomes is limited. Challenges to implementation include physician concern regarding surgical risks and patient education. Studies investigating patient-based outcomes are lacking. Bilateral salpingectomy for surgical sterilization is a reasonable option when patients are appropriately informed. Ovarian cancer risk reduction should be one of several factors considered when patients choose a surgical sterilization method.