Abaza, Amani F; El Shazly, Soraya A; Selim, Heba S A; Aly, Gehan S A
2017-09-27
Pseudomonas aeruginosa has emerged as a major healthcare associated pathogen that creates a serious public health disaster in both developing and developed countries. In this work we aimed at studying the occurrence of metallo-beta-lactamase (MBL) producing P. aeruginosa in a healthcare setting in Alexandria, Egypt. This cross sectional study included 1583 clinical samples that were collected from patients admitted to Alexandria University Students' Hospital. P. aeruginosa isolates were identified using standard microbiological methods and were tested for their antimicrobial susceptibility patterns using single disc diffusion method according to the Clinical and Laboratory Standards Institute recommendations. Thirty P. aeruginosa isolates were randomly selected and tested for their MBL production by both phenotypic and genotypic methods. Diagnostic Epsilometer test was done to detect metallo-beta-lactamase enzyme producers and polymerase chain reaction test was done to detect imipenemase (IMP), Verona integron-encoded (VIM) and Sao Paulo metallo-beta-lactamase (IMP) encoding genes. Of the 1583 clinical samples, 175 (11.3%) P. aeruginosa isolates were identified. All the 30 (100%) selected P. aeruginosa isolates that were tested for MBL production by Epsilometer test were found to be positive; where 19 (63.3%) revealed blaSPM gene and 11 (36.7%) had blaIMP gene. blaVIM gene was not detected in any of the tested isolates. Isolates of MBL producing P. aeruginosa were highly susceptible to polymyxin B 26 (86.7%) and highly resistant to amikacin 26 (86.7%). MBL producers were detected phenotypically by Epsilometer test in both carbapenem susceptible and resistant P. aeruginosa isolates. blaSPM was the most commonly detected MBL gene in P. aeruginosa isolates.
Alippi, Adriana M; Reynaldi, Francisco J; López, Ana C
2013-01-01
American foulbrood (AFB) is a bacterial disease caused by the spore-forming, grampositive bacterium Paenibacillus larvae, which affects honeybee broods worldwide. The aim of this work was to compare the Epsilometer test (Etest) to the agar dilution method for testing a collection of 22 P. larvae strains to tetracycline by using MYPGP and Iso- Sensitest agars. Results showed that a categorical agreement of 100% was found when using Iso-Sensitest, while a categorical agreement of 86.36% was found (with 3 minor errors) when MYPGP was tested. In conclusion, the Etest could be a rapid and reliable method for testing MIC values of tetracycline in P. larvae only when used in combination with Iso-Sensitest agar. Nevertheless, these results should be confirmed with future studies involving a larger number of isolates. Copyright © 2013 Asociación Argentina de Microbiología. Publicado por Elsevier España. All rights reserved.
Agarwal, Loveleena; Singh, Amit Kumar; Sengupta, Chandrim; Agarwal, Amitabh
2015-01-01
Methicillin-resistant Staphylococcus aureus (MRSA) ranks top among the nosocomial pathogens. Nasal formulation of mupirocin is found to eradicate MRSA from colonized individuals, but the emergence of resistant strains is a matter of concern. Nasal swabs were collected from 200 health care workers (HCWs) who were screened for MRSA. Kirby-Bauer disc diffusion method was used to perform antibiotic susceptibility test. MRSA detection was done using a cefoxitin 30 µg disc and interpreted according to the Clinical and Laboratory Standards Institute guidelines. Determination of mupirocin resistance was performed using Epsilometer test (E-test). About 14% of HCWs showed nasal carriage of MRSA. Nursing orderlies were the predominant carriers. E-test showed four mupirocin resistant isolates. The antibiogram of the MRSA isolates revealed the higher resistance to antibiotics as compared to methicillin-sensitive Staphylococcus aureus. All the MRSA isolates were sensitive to linezolid. HCWs in our hospital showed high nasal carriage rate of MRSA, particularly the nursing orderlies which is statistically significant. It is advisable to detect mupirocin resistance among the isolates obtained from the HCWs so that in case of resistance, alternative treatment should be sought.
Chaves, Sandra; Gadanho, Mário; Tenreiro, Rogério; Cabrita, José
1999-01-01
Metronidazole susceptibility of 100 Helicobacter pylori strains was assessed by determining the inhibition zone diameters by disk diffusion test and the MICs by agar dilution and PDM Epsilometer test (E test). Linear regression analysis was performed, allowing the definition of significant linear relations, and revealed correlations of disk diffusion results with both E-test and agar dilution results (r2 = 0.88 and 0.81, respectively). No significant differences (P = 0.84) were found between MICs defined by E test and those defined by agar dilution, taken as a standard. Reproducibility comparison between E-test and disk diffusion tests showed that they are equivalent and with good precision. Two interpretative susceptibility schemes (with or without an intermediate class) were compared by an interpretative error rate analysis method. The susceptibility classification scheme that included the intermediate category was retained, and breakpoints were assessed for diffusion assay with 5-μg metronidazole disks. Strains with inhibition zone diameters less than 16 mm were defined as resistant (MIC > 8 μg/ml), those with zone diameters equal to or greater than 16 mm but less than 21 mm were considered intermediate (4 μg/ml < MIC ≤ 8 μg/ml), and those with zone diameters of 21 mm or greater were regarded as susceptible (MIC ≤ 4 μg/ml). Error rate analysis applied to this classification scheme showed occurrence frequencies of 1% for major errors and 7% for minor errors, when the results were compared to those obtained by agar dilution. No very major errors were detected, suggesting that disk diffusion might be a good alternative for determining the metronidazole sensitivity of H. pylori strains. PMID:10203543
Catheter-related sepsis due to Rhodotorula glutinis.
Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay
2003-02-01
We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 microg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns.
Is Vancomycine Still a Choice for Chronic Osteomyelitis Empirical Therapy in Iran?
Izadi, Morteza; Zamani, Mohammad Mahdi; Mousavi, Seyed Ahmad; Sadat, Seyed Mir Mostafa; Siami, Zeinab; Vais Ahmadi, Noushin; Jonaidi Jafari, Nematollah; Shirvani, Shahram; Majidi Fard, Mojgan; Imani Fooladi, Abbas Ali
2012-01-01
Background Pyogenic bacteria and especially Staphylococcus aurous (S. aurous) are the most common cause of chronic osteomyelitis. Not only treatment protocol of chronic osteomyelitis occasionally is amiss but also this malady responds to treatment difficultly. Objectives This study investigates antibiotic resistance pattern of S. aurous isolated from Iranian patients who suffer from chronic osteomyelitis by two methods: disk diffusion (Kirby bauyer) and E-test (Epsilometer test) to find Vancomycin susceptibility and MIC (Minimum inhibitory concentration). Patients and Methods One hundred and thirty one patients who suffer from chronic osteomyelitis which have been referred to both governmental and private hospitals at 2010 were tried out for culturing of osteomyelitis site (sites). Antibiotic susceptibility and MIC of isolated bacteria were investigated by Kirby bauyer and E-test respectively. Results Samples were collected from bone (73.4%), surrounding tissue (14.6%) and wound discharge (12%). S. aureus was isolated from 49.6% of the samples. According to disc diffusion, methicillin resistance S. aureus (MRSA) was 75% and Vancomycin resistance S. aurous (VRSA) was 0% and based on MIC, MRSA was 68.5% and VRSA was 0%. According to MIC experiments, maximum sensitivity was against to Vancomycin (90.2%) and ciprofloxacin (54.4%) respectively but based on disc diffusion, maximum sensitivity was against to Vancomycin (97.7%) and ciprofloxacin (43.2%), respectively (P = 0.001). E-test (9.8%) in comparison with Disc diffusion (2.3%) showed higher percent of intermediate susceptibility to Vancomycin (P = 0.017). Conclusions Comparison of antibiograms and MICs showed that Kirby bauyer technique especially for detection of VISA strains is not reliable comparison with E-test. Already VRSA strains have not detected in Iranian chronic osteomyelitis, Thus Vancomycin is the first choice for chronic osteomyelitis empirical therapy in Iran yet. PMID:23483042
Catheter-Related Sepsis Due to Rhodotorula glutinis
Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay
2003-01-01
We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 μg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns. PMID:12574300
Taherpour, Arezou; Hashemi, Ali; Erfanimanesh, Soroor; Taki, Elahe
2016-07-01
Pseudomonas aeruginosa is one of the major bacteria causing acute infections. β-Lactamase production is the principal defense mechanism in gram-negative bacteria. The aim of our study was to evaluate the antibacterial activity of Methanolic Extracts of Green and Black Teas on P. aeruginosa Extended Spectrum-β-Lactamases (ESBLs) production. This research was carried out on burn wounds of 245 hospitalized patients in Kerman, Iran. P. aeruginosa ESBLs and MBL producing strains were detected by Combination Disk Diffusion Test (CDDT) and Epsilometer test (E-test) strips, respectively. Minimum inhibitory concentration (MIC) was measured for Ceftazidime, Meropenem, Imipenem, Aztreonam, Cefotaxime and methanollic extracts of Camellia Sinensis (Green Tea). From 245 patients in the burn ward, 120 cases were infected with P. aeruginosa. 41 isolates contained ESBL while MBL was not detected. P. aeruginosa were resistant to Cefotaxime, Aztreonam, Ceftazidime, Meropenem and Imipenem, 72 (60%), 50 (41.66%), 79 (65.83%), 33 (27.5%) and 24 (20%), respectively. Green tea extract had the highest anti-bacterial effect on standard and P. aeruginosa strains in 1.25mg/ml concentration. This study determined that the methanolic extract of green tea has a higher effect against ESBL producing P. aeruginosa than Cefotaxime, Aztreonam and Ceftazidime.
Jahansepas, Ali; Ahangarzadeh Rezaee, Mohammad; Hasani, Alka; Sharifi, Yaeghob; Rahnamaye Farzami, Marjan; Dolatyar, Alireza; Aghazadeh, Mohammad
2018-04-30
This study was conducted to investigate the phenotypic and genotypic characteristics of vancomycin-resistant Enterococcus faecalis and Enterococcus faecium. Antibiotic resistance and virulence genes in the aforementioned resistant isolates were studied using the epsilometer (E)-test and polymerase chain reaction (PCR). These isolates were subjected to typing by pulsed-field gel electrophoresis (PFGE). Thirty vancomycin-resistant enterococci (VRE; 18.75%) were isolated from a total of 160 various clinical specimens cultured for any bacterial growth. Of these, 11 (36.7%) isolates were identified as E. faecalis and 19 (63.3%) as E. faecium. Minimum inhibitory concentrations (MICs) of vancomycin, teicoplanin, and three alternative therapeutic options (linezolid, daptomycin, and quinupristin/dalfopristin) were determined using the E-test. Multiplex PCR was done for confirming species, identification of the resistant genotypes, and the detection of the virulence genes. Finally, the clonal relationship of all VRE strains was studied by PFGE. All VRE strains showed vancomycin MIC ≥256 μg/mL, and 27 (90%) isolates carried the vanA gene, whereas none of the isolates carried vanB. The most common resistance antibiotic pattern observed was toward rifampicin (n = 30 [100%]). Among all virulence genes studied, gelE (n = 28 [93.33%]) was found as the most prevalent virulent gene. VRE isolates exhibited 90%, 46.67%, 100%, and 66.67% resistance to teicoplanin, linezolid, quinupristin/dalfopristin, and daptomycin, respectively. Molecular typing demonstrated 16 PFGE types of VRE isolates (A-P). Although vanA was carried by most of the isolates, PFGE displayed small clonal dissemination among VR E. faecium and VR E. faecalis species.
Fungemia due to Lachancea fermentati: a case report.
Leuck, Anne-Marie; Rothenberger, Meghan K; Green, Jaime S
2014-05-10
Lachancea fermentati is an environmental yeast that is also used in the fermentation of alcoholic drinks. It has not previously been described as a human pathogen although the closely related yeast, Saccharomyces boulardii, can cause fungemia. Here we report a case of L. fermentati acting as a pathogen in a septic patient with cultures positive from blood, peritoneal fluid, bile, and sputum. A 36 year-old Caucasian man was hospitalized with acute alcoholic hepatitis complicated by Escherichia coli spontaneous bacterial peritonitis. Three days after admission, he developed new fevers with sepsis requiring mechanical ventilation and vasopressor support. He was found to have a bowel perforation. Cultures from blood, peritoneal fluid, and sputum grew a difficult-to-identify yeast. Micafungin was started empirically. On hospital day 43 the yeast was identified as L. fermentati with low minimum inhibitory concentrations (by Epsilometer test) to all antifungals tested. Micafungin was changed to fluconazole to complete a 3-month course of therapy. Serial peritoneal fluid cultures remained positive for 31 days. One year after his initial hospitalization the patient had ongoing cirrhosis but had recovered from fungemia. This case demonstrates the need for clinicians to consider host factors when interpreting culture results with normally non-pathogenic organisms. In this immunocompromised host L. fermentati caused disseminated disease. We believe his hobby of brewing alcohol led to colonization with L. fermentati, which then resulted in invasive disease when the opportunity arose.
Vilaichone, Ratha-korn; Ratanachu-ek, Thawee; Gamnarai, Pornpen; Chaithongrat, Supakarn; Uchida, Tomahisa; Yamaoka, Yoshio; Mahachai, Varocha
2016-01-01
This study aimed to survey the prevalence, patterns of antibiotic resistance, and clinical factors associated with antibiotic resistance in Helicobacter pylori among the Karen and Hmong mountain people of Thailand. We recruited dyspeptic patients in the Maesod district, Tak Province, Thailand. All subjects underwent upper gastrointestinal endoscopy, and three antral gastric biopsies were obtained for rapid urease tests and culture. An epsilometer was used to determine the minimum inhibitory concentrations of amoxicillin (AMX), clarithromycin (CLR), metronidazole (MNZ), levofloxacin (LVX), ciprofloxacin (CIP), and tetracycline (TET). A total of 291 subjects were enrolled; 149 (51.2%) were infected with H. pylori. Helicobacter pylori infection was present in 47.1% of Thai, 51.7% of Karen, and 58.7% of Hmong subjects. Antibiotic resistance was present in 75.8% including AMX (0.8%), TET (0%), CLR (5.6%), MNZ (71.8%), CIP (19.4%), LVX (19.4%), and multidrug resistance in 21.8%. Karen subjects had the highest prevalence of MNZ resistance (84.6%), and Hmong subjects had the highest prevalence of fluoroquinolone (27.3%) and multidrug (34.1%) resistance. MNZ plus fluoroquinolone (14.5%) was the most common multidrug resistance. There was no association between clinical factors and antibiotic resistance. MNZ resistance was prevalent, whereas fluoroquinolone- and multidrug-resistant H. pylori infections are important problems in mountain people of Thailand. PMID:26880772
Mombelli, Andrea; Cionca, Norbert; Almaghlouth, Adnan; Cherkaoui, Abdessalam; Schrenzel, Jacques; Giannopoulou, Catherine
2016-05-01
Previous studies have focused on antibiotic resistance of Gram-negative bacteria before and after periodontal therapy. The purpose of this analysis is to assess changes in resistance patterns of the commensal Gram-positive microbiota. The viridans group streptococci (VGS) have been suggested to serve as reservoirs of resistance genes for more pathogenic streptococci and may be implicated in some non-oral infections. In this randomized clinical trial, 80 patients with periodontitis are distributed randomly into two groups. In group A, patients received 375 mg amoxicillin and 500 mg metronidazole three times per day for 7 days during the non-surgical treatment phase (T1). In group B, the antibiotics were administered during the surgical phase (T2). Resistance of VGS to penicillin and erythromycin was determined by the epsilometer test. At baseline, VGS from 12.5% (group A) and 11.8% (group B) of patients had a minimum inhibitory concentration (MIC) >2 μg/mL to penicillin. Three months after T1, VGS from 15.6% and 16.7% of patients had an MIC >2 μg/mL, respectively. Six months after T2 VGS from 5.9% and 5.9% and 12 months after T2 VGS from 6.1% and 6.3% patients had an MIC >2 μg/mL. There was no effect of therapy with antibiotics, administered either in T1 or T2, on the carriage of penicillin-resistant VGS. Erythromycin resistance was high at baseline and remained unchanged throughout the study. MICs for penicillin and erythromycin were correlated (P <0.05). Amoxicillin plus metronidazole did not significantly affect the resistance pattern of the VGS to penicillin or erythromycin.
Cho, Jae Hoon; Suh, Jeffrey D; Kim, Jin Kook; Hong, Seok-Chan; Park, Il-Ho; Lee, Heung-Man
2014-01-01
Allergy test results can differ based on the method used. The most common tests include skin-prick testing (SPT) and in vitro tests to detect allergen-specific IgE. This study was designed to assess allergy test results using SPT, individual specific IgE tests, and a multiallergen IgE assay (multiple allergen simultaneous test) in patients with chronic rhinitis and controls. One hundred forty total patients were prospectively enrolled in the study, including 100 patients with chronic rhinitis and 40 control patients without atopy. All eligible patients underwent SPT, serum analysis using individual specific IgE test, and multiple allergen simultaneous test against 10 common allergens. Allergy test results were then compared to identify correlation and interest agreement. There was an 81-97% agreement between SPT and individual specific IgE test in allergen detection and an 80-98% agreement between SPT and multiple allergen simultaneous test. Individual specific IgE test and multiple allergen simultaneous test allergy detection prevalence was generally similar to SPT in patients with chronic rhinitis. All control patients had negative SPT (0/40), but low positive results were found with both individual specific IgE test (5-12.5%) and multiple allergen simultaneous test (2.5-7.5%) to some allergens, especially cockroach, Dermatophagoides farina, and ragweed. Agreement and correlation between individual specific IgE test and multiple allergen simultaneous test were good to excellent for a majority of tested allergens. This study shows good agreement and correlation between SPT with individual specific IgE test and multiple allergen simultaneous test on a majority of the tested allergens for patients with chronic rhinitis. Comparing the two in vitro tests, individual specific IgE test agrees with SPT better than multiple allergen simultaneous test.
2012-11-08
NASA recorded a historic week Nov. 5-9, conducting tests on all three stands in the E Test Complex at John C. Stennis Space Center. Inset images show the types of tests conducted on the E-1 Test Stand (right), the E-2 Test Stand (left) and the E-3 Test Stand (center). The E-1 photo is from an early October test and is provided courtesy of Blue Origin. Other photos are from tests conducted the week of Nov. 5.
12 CFR 563e.23 - Investment test.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 5 2011-01-01 2011-01-01 false Investment test. 563e.23 Section 563e.23 Banks... for Assessing Performance § 563e.23 Investment test. (a) Scope of test. The investment test evaluates... lending or service tests may not be considered under the investment test. (c) Affiliate investment. At a...
12 CFR 563e.23 - Investment test.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 6 2012-01-01 2012-01-01 false Investment test. 563e.23 Section 563e.23 Banks... for Assessing Performance § 563e.23 Investment test. (a) Scope of test. The investment test evaluates... lending or service tests may not be considered under the investment test. (c) Affiliate investment. At a...
12 CFR 563e.22 - Lending test.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 6 2012-01-01 2012-01-01 false Lending test. 563e.22 Section 563e.22 Banks and... Assessing Performance § 563e.22 Lending test. (a) Scope of test. (1) The lending test evaluates a savings... section. The OTS will not consider these loans under any criterion of the lending test except the...
12 CFR 563e.22 - Lending test.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 5 2011-01-01 2011-01-01 false Lending test. 563e.22 Section 563e.22 Banks and... Assessing Performance § 563e.22 Lending test. (a) Scope of test. (1) The lending test evaluates a savings... section. The OTS will not consider these loans under any criterion of the lending test except the...
Interpreting IgE sensitization tests in food allergy.
Chokshi, Niti Y; Sicherer, Scott H
2016-01-01
Food allergies are increasing in prevalence, and with it, IgE testing to foods is becoming more commonplace. Food-specific IgE tests, including serum assays and prick skin tests, are sensitive for detecting the presence of food-specific IgE (sensitization), but specificity for predicting clinical allergy is limited. Therefore, positive tests are generally not, in isolation, diagnostic of clinical disease. However, rationale test selection and interpretation, based on clinical history and understanding of food allergy epidemiology and pathophysiology, makes these tests invaluable. Additionally, there exist highly predictive test cutoff values for common allergens in atopic children. Newer testing methodologies, such as component resolved diagnostics, are promising for increasing the utility of testing. This review highlights the use of IgE serum tests in the diagnosis of food allergy.
40 CFR 92.124 - Test sequence; general requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (e) Pre-test engine measurements (e.g., idle and throttle notch speeds, fuel flows, etc.), pre-test engine performance checks (e.g., verification of engine power, etc.) and pre-test system calibrations (e... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Test sequence; general requirements...
40 CFR 92.124 - Test sequence; general requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (e) Pre-test engine measurements (e.g., idle and throttle notch speeds, fuel flows, etc.), pre-test engine performance checks (e.g., verification of engine power, etc.) and pre-test system calibrations (e... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Test sequence; general requirements. 92...
40 CFR 92.124 - Test sequence; general requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (e) Pre-test engine measurements (e.g., idle and throttle notch speeds, fuel flows, etc.), pre-test engine performance checks (e.g., verification of engine power, etc.) and pre-test system calibrations (e... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Test sequence; general requirements...
40 CFR 92.124 - Test sequence; general requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (e) Pre-test engine measurements (e.g., idle and throttle notch speeds, fuel flows, etc.), pre-test engine performance checks (e.g., verification of engine power, etc.) and pre-test system calibrations (e... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Test sequence; general requirements...
40 CFR 92.124 - Test sequence; general requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (e) Pre-test engine measurements (e.g., idle and throttle notch speeds, fuel flows, etc.), pre-test engine performance checks (e.g., verification of engine power, etc.) and pre-test system calibrations (e... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Test sequence; general requirements...
Looking northeast from Test Stand 'A' superstructure towards Test Stand ...
Looking northeast from Test Stand 'A' superstructure towards Test Stand 'D' tower (4223/E-24, left background), Test Stand 'C' tower (4217/E-18, center), and Test Stand 'B' (4215/E-16, right foreground). - Jet Propulsion Laboratory Edwards Facility, Edwards Air Force Base, Boron, Kern County, CA
12 CFR 563e.23 - Investment test.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Investment test. 563e.23 Section 563e.23 Banks... for Assessing Performance § 563e.23 Investment test. (a) Scope of test. The investment test evaluates... qualified investments that benefit its assessment area(s) or a broader statewide or regional area that...
12 CFR 563e.24 - Service test.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 6 2012-01-01 2012-01-01 false Service test. 563e.24 Section 563e.24 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY COMMUNITY REINVESTMENT Standards for Assessing Performance § 563e.24 Service test. (a) Scope of test. The service test evaluates a savings...
12 CFR 563e.24 - Service test.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 5 2011-01-01 2011-01-01 false Service test. 563e.24 Section 563e.24 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY COMMUNITY REINVESTMENT Standards for Assessing Performance § 563e.24 Service test. (a) Scope of test. The service test evaluates a savings...
E-4 Test Facility Design Status
NASA Technical Reports Server (NTRS)
Ryan, Harry; Canady, Randy; Sewell, Dale; Rahman, Shamim; Gilbrech, Rick
2001-01-01
Combined-cycle propulsion technology is a strong candidate for meeting NASA space transportation goals. Extensive ground testing of integrated air-breathing/rocket system (e.g., components, subsystems and engine systems) across all propulsion operational modes (e.g., ramjet, scramjet) will be needed to demonstrate this propulsion technology. Ground testing will occur at various test centers based on each center's expertise. Testing at the NASA John C. Stennis Space Center will be primarily concentrated on combined-cycle power pack and engine systems at sea level conditions at a dedicated test facility, E-4. This paper highlights the status of the SSC E-4 test Facility design.
Joint High Speed Vessel (JHSV) Follow on Operational Test and Evaluation (FOT and E) Report
2015-09-21
Speed Vessel (JHSV) ship class. The events covered in this testing were not performed during the Initial Operational Test and Evaluation ( IOT &E...support boats since launch of these type boats was completed in IOT &E. 1 “Initial Operational Test...and Evaluation ( IOT &E) with Live Fire Test and Evaluation (LFT&E) on Joint High Speed Vessel (JHSV),” DOT&E, July 17, 2014. 2 MLP (CCS) is a heavy
21 CFR 862.1090 - Angiotensin converting enzyme (A.C.E.) test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Angiotensin converting enzyme (A.C.E.) test system... Test Systems § 862.1090 Angiotensin converting enzyme (A.C.E.) test system. (a) Identification. An angiotensin converting enzyme (A.C.E.) test system is a device intended to measure the activity of angiotensin...
12 CFR 563e.22 - Lending test.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Lending test. 563e.22 Section 563e.22 Banks and... Assessing Performance § 563e.22 Lending test. (a) Scope of test. (1) The lending test evaluates a savings association's record of helping to meet the credit needs of its assessment area(s) through its lending...
Shtessel, Maria; Lobell, Elizabeth; Hudes, Golda; Rosenstreich, David; de Vos, Gabriele
2017-01-01
Background: Allergists commonly perform intradermal skin testing (IDST) after negative skin-prick testing (SPT) to comprehensively diagnose environmental allergic sensitization. However, with the availability of modern methods to detect serum-specific immunoglobulin E (ssIgE), it is unclear if ssIgE testing could substitute for IDST. Objective: To determine the efficacy of ssIgE testing and IDST when added to SPT in diagnosing environmental allergic sensitizations. Methods: SPT, IDST, and ssIgE testing to nine common environmental allergens were analyzed in 75 patients with oculonasal symptoms who presented to our allergy clinics in the Bronx, New York, between January 2014 and May 2015. Results: A total of 651 SPT and 499 ssIgE tests were independently performed and revealed 162 (25%) and 127 (25%) sensitizations, respectively. When SPT results were negative, IDST results revealed 108 of 452 additional sensitizations (24%). In contrast, when SPT results were negative, ssIgE test results only revealed 9% additional sensitizations. When both SPT and IDST results were negative, ssIgE testing only detected 3% of additional sensitizations, and ssIgE levels were typically low in these cases (median, 1.25 kU/L; range, 0.357–4.47 kU/L). When both SPT and ssIgE test results were negative, IDST results detected 15% additional sensitizations. Conclusion: IDST detected more additional environmental sensitizations compared with ssIgE testing. IDST, therefore, may be useful when the SPT and/or ssIgE testing results were negative, but the exposure history indicated relevant allergic sensitization. Serology added only a little more information if both SPT and IDST results were negative but may be useful in combination with SPT if IDST cannot be performed. PMID:28583228
Ferastraoaru, Denisa; Shtessel, Maria; Lobell, Elizabeth; Hudes, Golda; Rosenstreich, David; de Vos, Gabriele
2017-06-01
Allergists commonly perform intradermal skin testing (IDST) after negative skin-prick testing (SPT) to comprehensively diagnose environmental allergic sensitization. However, with the availability of modern methods to detect serum-specific immunoglobulin E (ssIgE), it is unclear if ssIgE testing could substitute for IDST. To determine the efficacy of ssIgE testing and IDST when added to SPT in diagnosing environmental allergic sensitizations. SPT, IDST, and ssIgE testing to nine common environmental allergens were analyzed in 75 patients with oculonasal symptoms who presented to our allergy clinics in the Bronx, New York, between January 2014 and May 2015. A total of 651 SPT and 499 ssIgE tests were independently performed and revealed 162 (25%) and 127 (25%) sensitizations, respectively. When SPT results were negative, IDST results revealed 108 of 452 additional sensitizations (24%). In contrast, when SPT results were negative, ssIgE test results only revealed 9% additional sensitizations. When both SPT and IDST results were negative, ssIgE testing only detected 3% of additional sensitizations, and ssIgE levels were typically low in these cases (median, 1.25 kU/L; range, 0.357-4.47 kU/L). When both SPT and ssIgE test results were negative, IDST results detected 15% additional sensitizations. IDST detected more additional environmental sensitizations compared with ssIgE testing. IDST, therefore, may be useful when the SPT and/or ssIgE testing results were negative, but the exposure history indicated relevant allergic sensitization. Serology added only a little more information if both SPT and IDST results were negative but may be useful in combination with SPT if IDST cannot be performed.
2012-11-08
A test of NASA's liquid oxygen, liquid methane Project Morpheus engine is conducted Nov. 8 on the E-3 Test Stand at John C. Stennis Space Center. The test was one of 27 conducted in Stennis' E Test Complex the week of Nov. 5. Twenty-seven tests were conducted in a three-day period during the week, on three different rocket engines/components and on three E Complex test stands.
21 CFR 862.1815 - Vitamin E test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vitamin E test system. 862.1815 Section 862.1815....1815 Vitamin E test system. (a) Identification. A vitamin E test system is a device intended to measure vitamin E (tocopherol) in serum. Measurements obtained by this device are used in the diagnosis and...
21 CFR 862.1815 - Vitamin E test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vitamin E test system. 862.1815 Section 862.1815....1815 Vitamin E test system. (a) Identification. A vitamin E test system is a device intended to measure vitamin E (tocopherol) in serum. Measurements obtained by this device are used in the diagnosis and...
21 CFR 862.1815 - Vitamin E test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vitamin E test system. 862.1815 Section 862.1815....1815 Vitamin E test system. (a) Identification. A vitamin E test system is a device intended to measure vitamin E (tocopherol) in serum. Measurements obtained by this device are used in the diagnosis and...
21 CFR 862.1815 - Vitamin E test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vitamin E test system. 862.1815 Section 862.1815....1815 Vitamin E test system. (a) Identification. A vitamin E test system is a device intended to measure vitamin E (tocopherol) in serum. Measurements obtained by this device are used in the diagnosis and...
NASA Technical Reports Server (NTRS)
Hughes, Mark S.; Hebert, Phillip W.; Davis, Dawn M.; Jensen, Scott L.; Abell, Frederick K., Jr.
2004-01-01
The John C. Stennis Space Center (SSC) provides test operations services to a variety of customers, including NASA, DoD, and commercial enterprises for the development of current and next-generation rocket propulsion systems. Many of these testing services are provided in the E-Complex test facilities composed of three active test stands (E1, E2, & E3) and 7 total test positions. Each test position is outfitted with unique sets of data acquisition and controls hardware and software that record both facility and test article data and enable safe operation of the test facility. This paper addresses each system in more detail including efforts to upgrade hardware and software.
... have an allergy. Other names: IgE allergy test, Quantitative IgE, Immunoglobulin E, Total IgE, Specific IgE What ... Thermo Fisher Scientific Inc.; c2017. ImmunoCAP – a truly quantitative allergy test [cited 2017 Feb 24]; [about 3 ...
1979-02-01
A 0 ’A099 7 1 3 tAU N A E R O S P A C E C O R P B E T H P A G E N Y F / 6 ~ ~ i DEVELOPMENT OF ENVIRONMENTAL. PROFILES FOR TESTING EQUIPMENT...IHIlia- ’ -Q IIIII.L25 MICROCOPY RESOLUTION’ TEST CHART C RMS-9-R-1 DEVELOPMENT OF ENVIRONMENTAL PROFILES FOR TESTING EQUIPMENT INSTALLED IN NAVAL... Development of Environmental Profiles for Testing ,’~ Final j quipment Installed in Naval Aircraft (Fixed Wing), e 7- e* 8 S. PERFORMING ORGANIZATION
Comparison of serum specific IgE with skin prick test in the diagnosis of allergy in Malaysia.
Asha'ari, Z A; Suhaimi, Y; Yusof, R A; Rushdan, I; Maraina, C H C
2011-08-01
We compared a newer serum specific IgE (SSIgE) test with skin prick testing (SPT) in the diagnosis of allergy in Malaysia. Ninety newly diagnosed allergic patients were enrolled for both tests. Using SPT as a clinical gold standard, the sensitivity, specificity, positive, and negative predictive values (PPV, NPV) were calculated for SSIgE for each of the common allergens tested. The highest positive results for both SPT and SSIgE were for house dust mite and cat. Compared to SPT, SSIgE showed better sensitivity but poorer specificity, low PPV and good NPV in all the allergens tested. Significant positive correlation was seen between the diameter of wheal and flare of SPT and the SSIgE results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, G.W.
1992-12-01
The project was undertaken to address the problem of MUG (4-methylumbelliferyl-B-D-glucuronide)-negative E. coli in water testing, and to develop a new, more reliable indole-based test for E. coli. In a study involving 39 healthy human volunteers, it was found that 1/3 of E. coli isolated from fresh human fecal samples tested MUG-negative in lauryl tryptose broth with MUG. It was further discovered: (1) The presence of simple sugars can cause catabolite repression of beta-GUR in a small percentage of E coli. (2) In gene probe studies, almost all E. coli isolates have portions of the uidA (GUR) gene sequence. Basedmore » on these two findings, catabolite repression can only be a partial explanation for the high-rate of GUR-negative E. coli. The authors improved the E. coli confirmatory medium, EC + MUG by removing the lactose, which allows for a stronger MUG test and the inclusion of the more reliable indole test. They called this newly improved medium INDEC, for Indole and EC medium. They later developed Colitag 3, a one-day, single tube indole-based test for E. coli.« less
An Evaluation of Blood Cholinesterase Testing Methods for Military Health
2008-05-01
activity found that only one device has been validated for ChE testing in the field: the Model 400 Test-mate™ ChE kit by EQM Research, Inc. (Cincinnati...OH). Suggested future modifications to the Model 400 Test-mate™ ChE kit include displaying/recording of acetyl-ChE activity uncorrected for...cholinesterase activity , that are routinely monitored by the Department of Defense (DoD). Within DoD, definitive cholinesterase testing is conducted by
Implementation of the soil compactor analyzer into test method TEX-113-E : technical report.
DOT National Transportation Integrated Search
2012-04-01
Test method Tex-113-E prepares laboratory aggregate base test specimens with an impact hammer : compactor. These specimens are used for compaction characteristics and design tests. Although the : historical Tex-113-E required a certain amount of comp...
Overview of Propellant Delivery Systems at the NASA John C. Stennis Space Center
NASA Technical Reports Server (NTRS)
Haselmaier, L. Haynes; Field, Robert E.; Ryan, Harry M.; Dickey, Jonathan C.
2006-01-01
A wide range of rocket propulsion test work occurs at he NASA John C. Stennis Space Center (SSC) including full-scale engine test activities at test facilities A-1, A-2, B-1 and B-2 as well as combustion device research and development activities at the E-Complex (E-1, E-2. E-3 and E-4) test facilities. One of the greatest challenges associated with operating a test facility is maintaining the health of the primary propellant system and test-critical support systems. The challenge emerges due to the fact that the operating conditions of the various system components are extreme (e.g., low temperatures, high pressures) and due to the fact that many of the components and systems are unique. The purpose of this paper is to briefly describe the experience and modeling techniques that are used to operate the unique test facilities at NASA SSC that continue to support successful propulsion testing.
TESTS TO ASSESS SENSITIZATION TO ASPERGILLUS FUMIGATUS IN CYSTIC FIBROSIS
Aguiar, Simone Santana; Damaceno, Neiva; Forte, Wilma Carvalho Neves
2017-01-01
ABSTRACT Objective: To evaluate the results of the tests used to identify the IgE mediated sensitization to Aspergillus fumigatus in patients with cystic fibrosis. Methods: This is a cross-sectional descriptive study with a convenience sample of 86 patients diagnosed with cystic fibrosis in the Reference Service in Cystic Fibrosis at a tertiary teaching hospital. The following tests were performed to assess the sensitization to A. fumigatus in patients with cystic fibrosis: Total serum IgE, eosinophil count, fungus detection through oropharyngeal swab or sputum culture, serum-specific IgE, and immediate-type hypersensitivity (IgE) skin tests. We compared the results of the different tests performed. Results: In 33 (38.4%) patients with cystic fibrosis, with ages ranging from 1 to 33 years (median of 8 years), the IgE-mediated A. fumigatus sensitization test results were: in 16 patients, there was an increase in serum-specific IgE (>0.35 kU/L); in 23, skin tests were positive; and six had sensitization in both tests. We observed two patients with eosinophilia (>1,000 eosinophils/mm3) and seven with increasing total serum IgE (>1,000 IU/mL), all of whom obtained negative results in skin tests and had no IgE increase specific to A. fumigatus. A. fumigatus was not detected in oropharyngeal swabs and/or sputum culture of any patients. Conclusions: We conclude that, among the tests used to assess sensitization to A. fumigatus in cystic fibrosis patients, both serum-specific IgE and immediate-type hypersensitivity (IgE) skin tests are required. Serum eosinophilia and respiratory secretion culture were not essential in this study. PMID:28977288
Qiao, H-L; Liu, J-H; Yang, J; Dong, Z-M
2005-08-01
The aim of this study was to investigate the relationships between skin test, specific immunoglobulin (Ig) E and cytokines in penicillin allergy. We collected the sera of 259 patients with historical positive skin test to penicillins, with immediate positive skin test and with a negative skin test results. The positive rate of specific IgE antibodies in 259 patients was 62.2% (161) by using radioallergosorbent test (RAST). Of the eight kinds of antigenic determinants, the positive rates of specific IgE to major and minor determinants were 43.63% (113) and 52.51% (136), respectively (p < 0.05). In 122 patients with immediate positive skin test, when the degrees of skin test were +, 2+, 3+ and 4+, the positive rates of specific IgE were 45.7, 57.1, 85.2 and 100%, respectively. The levels of interleukin (IL)-4, IL-13 and interferon (IFN)-gamma in the sera of patients with positive skin test were significantly increased with the degree of positive skin test (p < 0.05). The combined use of major and minor determinants in RAST offers the better test for the detection of penicillin-specific IgE antibodies. IL-4, IL-13 and IFN-gamma play important roles in penicillin allergy.
Overview of Engineering Design and Analysis at the NASA John C. Stennis Space Center
NASA Technical Reports Server (NTRS)
Ryan, Harry; Congiardo, Jared; Junell, Justin; Kirkpatrick, Richard
2007-01-01
A wide range of rocket propulsion test work occurs at the NASA John C. Stennis Space Center (SSC) including full-scale engine test activities at test facilities A-1, A-2, B-1 and B-2 as well as combustion device research and development activities at the E-Complex (E-1, E-2, E-3 and E-4) test facilities. The propulsion test engineer at NASA SSC faces many challenges associated with designing and operating a test facility due to the extreme operating conditions (e.g., cryogenic temperatures, high pressures) of the various system components and the uniqueness of many of the components and systems. The purpose of this paper is to briefly describe the NASA SSC Engineering Science Directorate s design and analysis processes, experience, and modeling techniques that are used to design and support the operation of unique rocket propulsion test facilities.
4. Credit BG. View looking northeast at west facade of ...
4. Credit BG. View looking northeast at west facade of Test Stand 'E' 4259/E-60, solid rocket motor test facility. Wooden barricades to north and south of 4259/E-60 protect personnel and other facilities from flying debris in case of inadvertent explosions. Test Stand 'E' is accessed from the tunnel system by the inclined tube shown at the center of the image adjacent to a ladder. Racks running to the north (having the appearance of a low fence) carry electrical cables to Test Stand 'G' (Building 4271/E-72). - Jet Propulsion Laboratory Edwards Facility, Test Stand E, Edwards Air Force Base, Boron, Kern County, CA
Comparison of Various Methods in the Diagnosis of Entamoeba histolytica in Stool and Serum Specimens
Uslu, Hakan; Aktas, Osman; Uyanik, Muhammet Hamidullah
2016-01-01
Objective: Entamoeba histolytica is indistinguishable from Entamoeba dispar in direct microscopic examination. A definitive diagnosis of E. histolytica is important in terms of the treatment of the patient and to avoid unnecessary costs. This study’s aim is to determine the prevalence of E. histolytica and to make a comparison of the different diagnostic tests in the patients specimens defined as E. histolytica/E. dispar infection. Materials and Methods: Faecal and serum specimens of 90 patients defined as E. histolytica/E. dispar with microscopy (wet mount examination with 0.85% saline and Lugol’s iodine) were examined. Stool samples were examined by trichrome staining for trophozoites and cysts and by immunoassay methods for specific adhesin antigens (Wampole ® E. histolytica II antigen testing) and for specific serine-rich 30 kD membrane protein (Serazym® E. histolytica antigen testing). Anti-E. histolytica antibodies were investigated using a latex slide test and indirect hemagglutination methods in serum specimens. Results: Presence of E. histolytica was not confirmed in 31.1% cases with trichrome staining, 62.2% of the Wampole antigen test, 64.4%, of the Serazym antigen test, 73.3% of the indirect hemagglutination test and 75.6%. of the latex agglutination. Considering the common results from Wampole and Serazym antigen testing as a reference standard, the specificity/sensitivity is 100/53.85% for trichrome staining, 75.00/98.11% for the latex agglutination test and 78.57/96.77% for the indirect hemagglutination test. Conclusion: It has been shown that investigation of E. histolytica in stools by direct wet-smear microscopy alone can cause significant false positive results. To obtain a reliable diagnosis for E. histolytica and to avoid unnecessary treatment for this parasite, at least one more specific assay, particularly an antigen testing and microscopy, is required. PMID:27551176
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption of Water Heaters E Appendix E to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. E Appendix E to Subpart B of Part 430—Uniform Test Method...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening test for HBsAg); and (4) Hepatitis C (e.g., FDA licensed screening test for anti-HCV). (b) In the case... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
NASA Astrophysics Data System (ADS)
Dimmler, M.; Marrero, J.; Leveque, S.; Barriga, P.; Sedghi, B.; Mueller, M.
2012-09-01
During the advanced design phase of the European Extremely Large Telescope (E-ELT) several critical components have been prototyped. During the last year some of them have been tested in dedicated test stands. In particular, a representative section of the E-ELT primary mirror has been assembled with 2 active and 2 passive segments. This test stand is equipped with complete prototype segment subunits, i.e. including support mechanisms, glass segments, edge sensors, position actuators as well as additional metrology for monitoring. The purpose is to test various procedures such as calibration, alignment and handling and to study control strategies. In addition the achievable component and subsystem performances are evaluated, and interface issues are identified. In this paper an overview of the activities related to the E-ELT M1 Test Facility will be given. Experiences and test results are presented.
13. Photographic copy of site plan displaying Test Stand 'C' ...
13. Photographic copy of site plan displaying Test Stand 'C' (4217/E-18), Test Stand 'D' (4223/E-24), and Control and Recording Center (4221/E-22) with ancillary structures, and connecting roads and services. California Institute of Technology, Jet Propulsion Laboratory, Facilities Engineering and Construction Office 'Repairs to Test Stand 'C,' Edwards Test Station, Legend & Site Plan M-1,' drawing no. ESP/115, August 14, 1987. - Jet Propulsion Laboratory Edwards Facility, Test Stand C, Edwards Air Force Base, Boron, Kern County, CA
2007 Nissan Altima-2351 Hybrid Electric Vehicle Battery Test Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyler Gray; Chester Motloch; James Francfort
2010-01-01
The U.S. Department of Energy's (DOE) Advanced Vehicle Testing Activity (AVTA) conducts several different types of tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of on-road accelerated testing. This report documents the battery testing performed and the battery testing results for the 2007 Nissan Altima HEV, number 2351 (VIN 1N4CL21E87C172351). The battery testing was performed by the Electric Transportation Engineering Corporation (eTec). The Idaho National Laboratory and eTec conduct the AVTA for DOE’s Vehicle Technologies Program.
10 CFR 429.110 - Enforcement testing.
Code of Federal Regulations, 2013 CFR
2013-01-01
... DOE has reason to believe that a basic model is not in compliance it may test for enforcement. (2) DOE will select and test units pursuant to paragraphs (c) and (e) of this section. (3) Testing will be... lab is accredited to ISO/IEC 17025:2005(E) and DOE representatives witness the testing. (b) Test...
10 CFR 429.110 - Enforcement testing.
Code of Federal Regulations, 2014 CFR
2014-01-01
... DOE has reason to believe that a basic model is not in compliance it may test for enforcement. (2) DOE will select and test units pursuant to paragraphs (c) and (e) of this section. (3) Testing will be... lab is accredited to ISO/IEC 17025:2005(E) and DOE representatives witness the testing. (b) Test...
10 CFR 429.110 - Enforcement testing.
Code of Federal Regulations, 2012 CFR
2012-01-01
... DOE has reason to believe that a basic model is not in compliance it may test for enforcement. (2) DOE will select and test units pursuant to paragraphs (c) and (e) of this section. (3) Testing will be... lab is accredited to ISO/IEC 17025:2005(E) and DOE representatives witness the testing. (b) Test...
... 2014 More on this topic for: Parents Teens E. Coli Giardiasis Yersiniosis Stool Test: Bacteria Culture Stool Test: ... Stool Test: Ova and Parasites (O&P) Diarrhea E. Coli View more About Us Contact Us Partners Editorial ...
View looking west at Test Stand 'A' complex in morning ...
View looking west at Test Stand 'A' complex in morning sun. View shows Monitor Building 4203/E-4 at left, barrier (Building 4216/E-17) to right of 4203/E-4, and Test Stand 'A' tower. Attached structure to lower left of tower is Test Stand 'A' machine room which contained refrigeration equipment. Building in right background with Test Stand 'A' tower shadow on it is Assembly Building 4288/E-89, built in 1984. Row of ground-mounted brackets in foreground was used to carry electrical cable and/or fuel lines. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA
Alternative Fuels Data Center: Status Update: New Mid-Level Ethanol Blends
differs from Subject 87A-E85 in several key ways. This new certification path only requires one test fluid , an aggressive E25 fluid, rather than both an E25 and an E85 test fluid. Due to the lack of contracted with UL to conduct these tests at their laboratory. NREL will test the dispensers using an
40 CFR 90.411 - Post-test analyzer procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Post-test analyzer procedures. 90.411... Test Procedures § 90.411 Post-test analyzer procedures. (a) Perform a HC hang-up check within 60...), the test is void. (d) Read and record the post-test data specified in § 90.405(e). (e) For a valid...
40 CFR 90.411 - Post-test analyzer procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Post-test analyzer procedures. 90.411... Test Procedures § 90.411 Post-test analyzer procedures. (a) Perform a HC hang-up check within 60...), the test is void. (d) Read and record the post-test data specified in § 90.405(e). (e) For a valid...
40 CFR 90.411 - Post-test analyzer procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Post-test analyzer procedures. 90.411... Test Procedures § 90.411 Post-test analyzer procedures. (a) Perform a HC hang-up check within 60...), the test is void. (d) Read and record the post-test data specified in § 90.405(e). (e) For a valid...
40 CFR 90.411 - Post-test analyzer procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Post-test analyzer procedures. 90.411... Test Procedures § 90.411 Post-test analyzer procedures. (a) Perform a HC hang-up check within 60...), the test is void. (d) Read and record the post-test data specified in § 90.405(e). (e) For a valid...
40 CFR 90.411 - Post-test analyzer procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Post-test analyzer procedures. 90.411... Test Procedures § 90.411 Post-test analyzer procedures. (a) Perform a HC hang-up check within 60...), the test is void. (d) Read and record the post-test data specified in § 90.405(e). (e) For a valid...
Diagnostic value of the basophil activation test in evaluating Hymenoptera venom sensitization.
Peternelj, Andreja; Silar, Mira; Bajrovic, Nissera; Adamic, Katja; Music, Ema; Kosnik, Mitja; Korosec, Peter
2009-01-01
Diagnosis of allergy to Hymenoptera venom is usually confirmed with skin testing and measurement of specific serum IgE antibody, tests which are sometimes inconclusive. In these cases, additional in vitro tests are necessary. The aim of this study was to show the applicability of the basophil activation test in detecting sensitization to Hymenoptera venom and to compare the test sensitivity and clinical positive-predictive value with skin prick tests and measurement of allergen-specific serum IgE. This prospective study was conducted between June 2004 and December 2007 and included a large group of 204 patients. All patients had a history of at least one systemic allergic reaction of Müller grades II-IV after a Hymenoptera sting. We compared results of the basophil activation test, specific serum IgE and skin prick tests with patients' clinical history and data on culprit insects. The overall clinical sensitivities of the basophil activation test, specific serum IgE and skin prick tests were 90%, 76% and 64%, respectively; the clinical positive-predictive values of the three tests were 79%, 73% and 78% for bee venom, 86%, 59% and 43% for wasp venom; and 84%, 77% and 22% for both venoms. Our results revealed a higher clinical sensitivity and comparable or better clinical positive-predictive value of basophil activation tests than skin prick tests and allergen-specific serum IgE in the detection of allergy to Hymenoptera venom.
ERIC Educational Resources Information Center
Lowe, Patricia A.; Ang, Rebecca P.
2012-01-01
In the present study, the similarity of the factor structure of the Test Anxiety Scale for Elementary Students (TAS-E) and cultural and gender differences in test anxiety were examined in a sample of 1322 US and Singapore elementary students. The similarity of the factor structure of the TAS-E, a measure of test anxiety, was examined to determine…
NASA Technical Reports Server (NTRS)
Verrilli, Michael J.; Ellis, J. Rodney; Swindeman, Robert W.
1990-01-01
The American Society for Testing and Materials (ASTM) standard E606-80 is the most often used recommended testing practice for low-cycle-fatigue (LCF) testing in the United States. The standard was first adopted in 1977 for LCF testing at room temperature and was modified in 1980 to include high-temperature testing practices. Current activity within ASTM is aimed at extending the E606-80 recommended practices to LCF under thermomechanical conditions, LCF in high-pressure hydrogen, and LCF in metal-matrix composite materials. Interlaboratory testing programs conducted to generate a technical base for modifying E606-80 for the aforementioned LCF test types are discussed.
Preschool visual acuity screening tests.
Friendly, D S
1978-01-01
The purpose of the study was to evaluate the relative merits of two screening tests used for visual acuity assessment of preschool children. The tests that were compared were the Good-Lite Company versions of the E-Test and of the STYCAR (Screening Test for Young Children and Retardates). The former is the most popular method for evaluating central acuity in young children in this nation; the STYCAR is a relatively new letter-matching-test developed in England, where it is widely employed. The E-Test poses left-right orientation problems which are eliminated by the symmetrical letters H, T, O and V utilized in the Letter-Matching-Test. Both visual acuity tests were administered on two separate occasions by personnel from the Prevention of Blindness Society of Metropolitan Washington to 633 preschool children in Washington, D.C. By random selection, 150 of the children received the E-Test at both sessions, 162 children received the Letter-Matching-Test at both sessions, 160 chilt athe the second session, and 161 children received the Letter-Matching-Test at the first session and the E-Test at the second session. The author medically examined the eyes of 408 of the 633 children without knowledge of which test had been initially administered. Statistical analysis of the data obtained from the study indicated that the Letter-Matching-Test was significantly better in terms of testability rates, group and individual instruction time, and performance time. The E-Test was more reliable in terms of test-retest acuity scores and was also more valid in terms of agreement between pass-fail results obtained at the first screening session and two levels of pass-fail refraction criteria. Images FIGURE 4 FIGURE 5 FIGURE 7 A FIGURE 7 B FIGURE 9 A FIGURE 9 B PMID:754379
Discordance between Aeroallergen Specific Serum IgE and Skin Testing in Children < 4 years of age
de Vos, Gabriele; Nazari, Ramin; Ferastraoaru, Denisa; Parikh, Purvi; Geliebter, Rebecca; Pichardo, Yikania; Wiznia, Andrew; Rosenstreich, David
2015-01-01
Background Atopic sensitization to aeroallergens in early life has been shown to be a strong risk factor for developing persisting asthma in young children with recurrent wheeze. Objective The aim of this study was to assess the yield of skin prick test (SPT) compared to allergen specific serum IgE testing (sIgE) at identifying aeroallergen sensitization in atopic children < 4 years of age. Methods Concordance between SPT (Greer Laboratories, ComforTen™) and allergen specific sIgE (Immulite 2000™) for 7 common aeroallergens was analyzed in forty atopic inner-city children, 18–48 months of age (mean 36 +/− 9 months) with recurrent wheezing, family history of asthma and/or eczema. Results In 80% of children one or more allergen sensitizations would have been missed if only SPT had been performed, and in 38% of children one or more sensitizations would have been missed if only serum IgE testing had been performed. Agreement and between SPT and sIgE test was fair for most allergens (kappa between −0.04 and 0.50), as was correlation between sIgE levels and SPT grade (rho between 0.21 and 0.55). Children with high total sIgE (≥300 kU/l) were more likely to have sIgE positive tests with negative corresponding skin test (p=0.025). Conclusions Our study showed significant discordance between allergen specific SPT and sIgE testing results for common aeroallergens, suggesting that both SPT and sIgE testing should be done when diagnosing allergic sensitization in young children at high risk of asthma. PMID:23706713
de Vos, Gabriele; Nazari, Ramin; Ferastraoaru, Denisa; Parikh, Purvi; Geliebter, Rebecca; Pichardo, Yikania; Wiznia, Andrew; Rosenstreich, David
2013-06-01
Atopic sensitization to aeroallergens in early life has been found to be a strong risk factor for the development of persisting asthma in young children with recurrent wheeze. To assess the yield of skin prick test (SPT) compared with allergen specific serum IgE (sIgE) testing at identifying aeroallergen sensitization in atopic children younger than 4 years. Concordance between SPT and allergen-specific sIgE testing for 7 common aeroallergens was analyzed in 40 atopic inner-city children 18 to 48 months of age (mean [SD], 36 [9] months) with recurrent wheezing and family history of asthma and/or eczema. In 80% of children one or more allergen sensitizations would have been missed if only SPT had been performed, and in 38% of children one or more sensitizations would have been missed if only sIgE testing had been performed. Agreement between the SPT and sIgE test was fair for most allergens (κ = -0.04 to 0.50), as was correlation between sIgE levels and SPT grade (ρ = 0.21 to 0.55). Children with high total sIgE (≥300 kU/L) were more likely to have positive sIgE test results, with negative corresponding SPT results (P = .02). Our study revealed a significant discordance between allergen-specific SPT and sIgE testing results for common aeroallergens, suggesting that both SPT and sIgE testing should be performed when diagnosing allergic sensitization in young children at high risk of asthma. clinicaltrials.gov Identifier: NCT01028560. Copyright © 2013 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Tantilipikorn, Pongsakorn; Danpornprasert, Piyanart; Ngaotepprutaram, Premyot; Assanasen, Paraya; Bunnag, Chaweewan; Thinkhamrop, Bandit
2015-12-01
Diagnosis of allergic rhinitis (AR) is based on history, physical examination, and skin prick test (SPT) while intradermal (ID) test can be performed to confirm the diagnosis in case of negative result of SPT. However, the ID test is not recommended for cat and timothy grass allergy because of its high false positive rate. As a result, the "quantitative" technique of serum specific IgE (sIgE) measurement might be helpful to diagnose AR with more confidence. To evaluate the correlation between ID tests and sIgE in the diagnosis of house dust mite (HDM)-sensitive AR patients. Patients with chronic rhinitis (CR) were recruited and SPT was performed. If SPT was negative, ID test and sIgE to HDM [Dermatophagoides pteronyssinus (Dp)] measurement were performed. Eighty-two patients with chronic rhinitis (CR), whose SPTs were negative for Dp, were included. There were 39 males (47.6%) and 43 females (52.4%) aged between 18 and 76 years old (mean age = 43.3 years). The ID test was positive in 13 patients (15.9%), and was negative in 69 patients (84.1 %). sIgE to HDM was positive ( ≥ 0.35 kUA/l) in 2 patients (2.4%). There was a fair to moderate correlation between the size of wheal of ID test and sIgE to HDM (r = 0.44, 95% confidence interval: 0.19 to 0.67, p < 0.01). ID test has a fair to moderate correlation with sIgE Dermatophagoides pteronyssinus and it can be used in CR patients with negative SPT where sIgE is not feasible.
9 CFR 114.9 - Outline of Production guidelines.
Code of Federal Regulations, 2010 CFR
2010-01-01
... each satisfactory test. A. Purity. B. Safety. C. Potency. D. Other tests. VI. Post preparatory steps. A... test. A. Purity. B. Safety. C. Potency. D. Moisture, if desiccated. E. Any other tests. VI. Post.... Potency. D. Any other tests. E. Include any additional pertinent information. IV. Post preparatory steps...
9 CFR 114.9 - Outline of Production guidelines.
Code of Federal Regulations, 2012 CFR
2012-01-01
... each satisfactory test. A. Purity. B. Safety. C. Potency. D. Other tests. VI. Post preparatory steps. A... test. A. Purity. B. Safety. C. Potency. D. Moisture, if desiccated. E. Any other tests. VI. Post.... Potency. D. Any other tests. E. Include any additional pertinent information. IV. Post preparatory steps...
9 CFR 114.9 - Outline of Production guidelines.
Code of Federal Regulations, 2013 CFR
2013-01-01
... each satisfactory test. A. Purity. B. Safety. C. Potency. D. Other tests. VI. Post preparatory steps. A... test. A. Purity. B. Safety. C. Potency. D. Moisture, if desiccated. E. Any other tests. VI. Post.... Potency. D. Any other tests. E. Include any additional pertinent information. IV. Post preparatory steps...
9 CFR 114.9 - Outline of Production guidelines.
Code of Federal Regulations, 2011 CFR
2011-01-01
... each satisfactory test. A. Purity. B. Safety. C. Potency. D. Other tests. VI. Post preparatory steps. A... test. A. Purity. B. Safety. C. Potency. D. Moisture, if desiccated. E. Any other tests. VI. Post.... Potency. D. Any other tests. E. Include any additional pertinent information. IV. Post preparatory steps...
9 CFR 114.9 - Outline of Production guidelines.
Code of Federal Regulations, 2014 CFR
2014-01-01
... each satisfactory test. A. Purity. B. Safety. C. Potency. D. Other tests. VI. Post preparatory steps. A... test. A. Purity. B. Safety. C. Potency. D. Moisture, if desiccated. E. Any other tests. VI. Post.... Potency. D. Any other tests. E. Include any additional pertinent information. IV. Post preparatory steps...
2012-11-08
NASA engineer Andy Guymon studies data in the E-3 Test Stand Control Center at John C. Stennis Space Center during testing of NASA's Project Morpheus engine. Nov. 8. The test of the liquid oxygen, liquid methane engine was one of 27 conducted in Stennis' E Test Complex the week of Nov. 5.
2012-11-06
NASA engineers test a chemical steam generator (CSG) unit on the E-2 Test Stand at John C. Stennis Space Center on Nov. 6. The test was one of 27 conducted in Stennis' E Test Complex the week of Nov. 5. Twenty-seven CSG units will be used on the new A-3 Test Stand at Stennis to produce a vacuum that allows testing of engines at simulated altitudes up to 100,000 feet.
Advanced E-O test capability for Army Next-Generation Automated Test System (NGATS)
NASA Astrophysics Data System (ADS)
Errea, S.; Grigor, J.; King, D. F.; Matis, G.; McHugh, S.; McKechnie, J.; Nehring, B.
2015-05-01
The Future E-O (FEO) program was established to develop a flexible, modular, automated test capability as part of the Next Generation Automatic Test System (NGATS) program to support the test and diagnostic needs of currently fielded U.S. Army electro-optical (E-O) devices, as well as being expandable to address the requirements of future Navy, Marine Corps and Air Force E-O systems. Santa Barbara infrared (SBIR) has designed, fabricated, and delivered three (3) prototype FEO for engineering and logistics evaluation prior to anticipated full-scale production beginning in 2016. In addition to presenting a detailed overview of the FEO system hardware design, features and testing capabilities, the integration of SBIR's EO-IR sensor and laser test software package, IRWindows 4™, into FEO to automate the test execution, data collection and analysis, archiving and reporting of results is also described.
49 CFR 40.163 - How does the MRO report drug test results?
Code of Federal Regulations, 2014 CFR
2014-10-01
... tests, the drug(s)/metabolite(s) for which the test was positive; (8) For cancelled tests, the reason... for this purpose, you must provide a written report (e.g., a letter) for each test result. This report... for the test, if indicated on the CCF (e.g., random, post-accident); (4) Date of the collection; (5...
A test manager's perspective of a test concept for a heavy lift vehicle
NASA Technical Reports Server (NTRS)
Pargeon, John I., Jr.
1990-01-01
The developmment of a test concept is a significant part of the advanced planning activities accomplished for the Initial Operational Test and Evaluation (IOT&E) of new systems. A test concept is generally viewed as a description, including rationale, of the test structure, evaluation methodology and management approach required to plan and conduct the IOT&E of a program such as a new heavy lift launch vehicle system. The test concept as presented in this paper is made up of an operations area, a test area, an evaluation area, and a management area. The description presented here is written from the perspective of one test manager, and represents his views of a possible framework of a test concept using examples for a potential IOT&E of a heavy lift launch vehicle.
1. Photographic copy of engineering drawing showing elevations and sections ...
1. Photographic copy of engineering drawing showing elevations and sections of Test Stand 'E' (Building 4259/E-60). California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Solid Propellant Test Stand E-60 - Elevations & Sections,' sheet E60/10, no date. - Jet Propulsion Laboratory Edwards Facility, Test Stand E, Edwards Air Force Base, Boron, Kern County, CA
Code of Federal Regulations, 2011 CFR
2011-07-01
...: ASTM E 729-96 (Reapproved 2007) 3. Toxicity to Plants (Algae): ASTM E 1218-04 e1 Test Group 2 for C1: 1. Chronic Toxicity to Daphnia: ASTM E 1193-97 (Reapproved 2004) 2. Toxicity to Plants (Algae): ASTM E 1218... Plants (Algae): ASTM E 1218-04 e1 Test Group 2 for C2: 1. Chronic Toxicity to Daphnia: ASTM E 1193-97...
Code of Federal Regulations, 2013 CFR
2013-07-01
...: ASTM E 729-96 (Reapproved 2007) 3. Toxicity to Plants (Algae): ASTM E 1218-04 e1 Test Group 2 for C1: 1. Chronic Toxicity to Daphnia: ASTM E 1193-97 (Reapproved 2004) 2. Toxicity to Plants (Algae): ASTM E 1218... Plants (Algae): ASTM E 1218-04 e1 Test Group 2 for C2: 1. Chronic Toxicity to Daphnia: ASTM E 1193-97...
Code of Federal Regulations, 2012 CFR
2012-07-01
...: ASTM E 729-96 (Reapproved 2007) 3. Toxicity to Plants (Algae): ASTM E 1218-04 e1 Test Group 2 for C1: 1. Chronic Toxicity to Daphnia: ASTM E 1193-97 (Reapproved 2004) 2. Toxicity to Plants (Algae): ASTM E 1218... Plants (Algae): ASTM E 1218-04 e1 Test Group 2 for C2: 1. Chronic Toxicity to Daphnia: ASTM E 1193-97...
Code of Federal Regulations, 2014 CFR
2014-07-01
...: ASTM E 729-96 (Reapproved 2007) 3. Toxicity to Plants (Algae): ASTM E 1218-04 e1 Test Group 2 for C1: 1. Chronic Toxicity to Daphnia: ASTM E 1193-97 (Reapproved 2004) 2. Toxicity to Plants (Algae): ASTM E 1218... Plants (Algae): ASTM E 1218-04 e1 Test Group 2 for C2: 1. Chronic Toxicity to Daphnia: ASTM E 1193-97...
Fish allergy in atopic children.
Peng, Y H; Shyur, S D; Chang, C L; Lai, C L; Chu, S H; Wu, W C; Wu, C Y
2001-12-01
The prevalence of fish allergy among 11 atopic children with elevated levels of specific immunoglobulin (Ig) E for cod was determined. None of the children had a history of fish allergy. All of the children had asthma and allergic rhinitis and 5 of them had also atopic dermatitis. The children underwent allergy skin tests (codfish, tuna, catfish, salmon, flounder, and bass), specific IgE tests (salmon, trout, tuna, eel, and mackerel), and food challenge tests. Skin tests in cod-specific IgE-positive children were positive for codfish in 4 children, tuna in 2, catfish in 2, salmon in 6, flounder in one, and bass in 2. Three children had elevated specific IgE for salmon, 5 for trout, 8 for tuna, 4 for eel, and 4 for mackerel. Oral fish challenge with 10 g of fish did not result in positive reaction in any of the children. In conclusion, a positive food challenge test provided the only definitive confirmation of fish allergy, whereas positive allergy skin tests or positive specific IgE tests were less reliable. Skin tests and in vitro specific IgE assays were not correlated with clinical symptoms of fish allergy, and the results of these 2 tests did not correlate with each other in this study.
Okamoto-Uchida, Yoshimi; Nakamura, Ryosuke; Matsuzawa, Yumiko; Soma, Megumi; Kawakami, Hiroshi; Ishii-Watabe, Akiko; Nishimaki-Mogami, Tomoko; Teshima, Reiko; Saito, Yoshiro
2016-01-01
The physicochemical nature of allergen molecules differ from the liquid phase to the solid phase. However, conventional allergy tests are based on the detection of immunoglobulin (Ig)E binding to immobilized allergens. We recently developed an in vitro allergy testing method using a luciferase-reporting humanized rat mast cell line to detect IgE crosslinking-induced luciferase expression (EXiLE test). The aim of the present study was to evaluate the effects of antigen immobilization on the results of different in vitro allergy tests using two anti-ovalbumin (OVA) antibodies (Abs), E-C1 and E-G5, with different properties in the OVA-induced allergic reaction. Both Abs showed clear binding to OVA with an enzyme-linked immunosorbent assay and by BIAcore analysis. However, only E-C1 potentiated EXiLE response for the liquid-phase OVA. On the other hand, OVA immobilized on solid-phase induced EXiLE responses in both E-C1 Ab- and E-G5 Ab-sensitized mast cells. Western blotting of OVA indicated that E-C1 Ab binds both to OVA monomers and dimers, unlike E-G5 Ab, which probably binds only to the OVA dimer. These results suggest that antigen immobilization enhanced IgE crosslinking ability through multimerization of allergen molecules in the solid phase, resulting in an increase in false positives in IgE binding-based conventional in vitro allergy tests. These findings shed light on the physicochemical nature of antigens as an important factor for the development and evaluation of in vitro allergy tests and suggest that mast cell activation-based allergy testing with liquid-phase allergens is a promising strategy to evaluate the physiological interactions of IgE and allergens.
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2012 CFR
2012-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2014 CFR
2014-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2011 CFR
2011-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2013 CFR
2013-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
Overview of the Acoustic Testing of the European Service Module Structural Test Article (E-STA)
NASA Technical Reports Server (NTRS)
Hughes, William; Fogt, Vince; Le Plenier, Cyprien; Duval, Francois; Durand, Jean-Francois; Staab, Lucas D.; Hozman, Aron; Mcnelis, Anne; Bittinger, Samantha; Thirkettle, Anthony;
2017-01-01
The European Space Agency (ESA) and their prime contractor Airbus Defense Space (ADS) are developing the European Service Module (ESM) for integration and utilization with other modules of NASAs Orion Multi-Purpose Crew Vehicle. As part of this development, ESA, ADS, NASA and the Lockheed Martin Company performed a series of reverberant acoustic tests in April-May 2016 on the ESM Structural Test Article (E-STA), the mechanical mock-up of the ESM designated for mechanical tests. Testing the E-STA under acoustic qualification loads verifies whether it can successfully withstand the medium and high frequency mechanical environment occurring during the vehicles lift-off and atmospheric phases of flight. The testing occurred at the Reverberant Acoustic Test Facility (RATF) at the NASA Glenn Research Centers Plum Brook Station site in Sandusky, OH, USA. This highly successful acoustic test campaign excited the E-STA to acoustic test levels as high as 149.4 dB Overall Sound Pressure Level. This acoustic testing met all the ESA and ADSs test objectives, including establishingverifying the random vibration qualification test levels for numerous hardware components of the ESM, and qualifying the ESMs Solar Array Wing electrical power system. This paper will address the test objectives, the test articles configuration, the test instrumentation and excitation levels, the RATF site and capabilities, the series of acoustic tests performed, and the technical issues faced and overcome to result in a successful acoustic test campaign for the ESM. A discussion of several test results is also included.
Overview of the Acoustic Testing of the European Service Module Structural Test Article (E-STA)
NASA Technical Reports Server (NTRS)
Hughes, William; Le Plenier, Cyprien; Duval, Francois; Staab, Lucas; Hozman, Aron; Thirkettle, Anthony; Fogt, Vincent; Durand, Jean-Francois; McNelis, Anne; Bittinger, Samantha;
2017-01-01
The European Space Agency (ESA) and their prime contractor Airbus Defense Space (ADS) are developing the European Service Module (ESM) for integration and utilization with other modules of NASAs Orion Multi-Purpose Crew Vehicle. As part of this development, ESA, ADS, NASA and the Lockheed Martin Company performed a series of reverberant acoustic tests in April-May 2016 on the ESM Structural Test Article (E-STA), the mechanical mock-up of the ESM designated for mechanical tests. Testing the E-STA under acoustic qualification loads verifies whether it can successfully withstand the medium and high frequency mechanical environment occurring during the vehicles lift-off and atmospheric phases of flight. The testing occurred at the Reverberant Acoustic Test Facility (RATF) at the NASA Glenn Research Centers Plum Brook Station site in Sandusky, OH, USA. This highly successful acoustic test campaign excited the E-STA to acoustic test levels as high as 149.4 dB Overall Sound Pressure Level. This acoustic testing met all the ESA and ADSs test objectives, including establishing/verifying the random vibration qualification test levels for numerous hardware components of the ESM, and qualifying the ESMs Solar Array Wing electrical power system. This paper will address the test objectives, the test articles configuration, the test instrumentation and excitation levels, the RATF site and capabilities, the series of acoustic tests performed, and the technical issues faced and overcome to result in a successful acoustic test campaign for the ESM. A discussion of several test results is also included.
Standards in C.S.E. and G.C.E.: English and Mathematics. Working Paper No. 9.
ERIC Educational Resources Information Center
Schools Council, London (England).
Attainment tests in English and mathematics were administered to a total sample of 2,011/15-year old students. The English test consisted of a composition and a test battery of objective items. Marking of the composition was made by the test designer on a rapid first-impression reading. The objective test battery consisted of a comprehension test,…
Nakanishi, Hiroyoshi; Doyama, Hisashi; Ishikawa, Hideki; Uedo, Noriya; Gotoda, Takuji; Kato, Mototsugu; Nagao, Shigeaki; Nagami, Yasuaki; Aoyagi, Hiroyuki; Imagawa, Atsushi; Kodaira, Junichi; Mitsui, Shinya; Kobayashi, Nozomu; Muto, Manabu; Takatori, Hajime; Abe, Takashi; Tsujii, Masahiko; Watari, Jiro; Ishiyama, Shuhei; Oda, Ichiro; Ono, Hiroyuki; Kaneko, Kazuhiro; Yokoi, Chizu; Ueo, Tetsuya; Uchita, Kunihisa; Matsumoto, Kenshi; Kanesaka, Takashi; Morita, Yoshinori; Katsuki, Shinichi; Nishikawa, Jun; Inamura, Katsuhisa; Kinjo, Tetsu; Yamamoto, Katsumi; Yoshimura, Daisuke; Araki, Hiroshi; Kashida, Hiroshi; Hosokawa, Ayumu; Mori, Hirohito; Yamashita, Haruhiro; Motohashi, Osamu; Kobayashi, Kazuhiko; Hirayama, Michiaki; Kobayashi, Hiroyuki; Endo, Masaki; Yamano, Hiroo; Murakami, Kazunari; Koike, Tomoyuki; Hirasawa, Kingo; Miyaoka, Youichi; Hamamoto, Hidetaka; Hikichi, Takuto; Hanabata, Norihiro; Shimoda, Ryo; Hori, Shinichiro; Sato, Tadashi; Kodashima, Shinya; Okada, Hiroyuki; Mannami, Tomohiko; Yamamoto, Shojiro; Niwa, Yasumasa; Yashima, Kazuo; Tanabe, Satoshi; Satoh, Hiro; Sasaki, Fumisato; Yamazato, Tetsuro; Ikeda, Yoshiou; Nishisaki, Hogara; Nakagawa, Masahiro; Matsuda, Akio; Tamura, Fumio; Nishiyama, Hitoshi; Arita, Keiko; Kawasaki, Keisuke; Hoppo, Kazushige; Oka, Masashi; Ishihara, Shinichi; Mukasa, Michita; Minamino, Hiroaki; Yao, Kenshi
2017-10-01
Background and study aim Magnifying narrow-band imaging (M-NBI) is useful for the accurate diagnosis of early gastric cancer (EGC). However, acquiring skill at M-NBI diagnosis takes substantial effort. An Internet-based e-learning system to teach endoscopic diagnosis of EGC using M-NBI has been developed. This study evaluated its effectiveness. Participants and methods This study was designed as a multicenter randomized controlled trial. We recruited endoscopists as participants from all over Japan. After completing Test 1, which consisted of M-NBI images of 40 gastric lesions, participants were randomly assigned to the e-learning or non-e-learning groups. Only the e-learning group was allowed to access the e-learning system. After the e-learning period, both groups received Test 2. The analysis set was participants who scored < 80 % accuracy on Test 1. The primary end point was the difference in accuracy between Test 1 and Test 2 for the two groups. Results A total of 395 participants from 77 institutions completed Test 1 (198 in the e-learning group and 197 in the non-e-learning group). After the e-learning period, all 395 completed Test 2. The analysis sets were e-learning group: n = 184; and non-e-learning group: n = 184. The mean Test 1 score was 59.9 % for the e-learning group and 61.7 % for the non-e-learning group. The change in accuracy in Test 2 was significantly higher in the e-learning group than in the non-e-learning group (7.4 points vs. 0.14 points, respectively; P < 0.001). Conclusion This study clearly demonstrated the efficacy of the e-learning system in improving practitioners' capabilities to diagnose EGC using M-NBI.Trial registered at University Hospital Medical Information Network Clinical Trials Registry (UMIN000008569). © Georg Thieme Verlag KG Stuttgart · New York.
Approach to evaluation and management of a patient with multiple food allergies.
Bird, J Andrew
2016-01-01
Diagnosing food allergy is often challenging, and validated testing modalities are mostly limited to immunoglobulin E (IgE)-mediated reactions to foods. Use of food-specific IgE tests and skin prick tests in individuals without a history that supports an IgE-mediated reaction to the specific food being tested diminishes the predictive capabilities of the test. To review the literature regarding evaluation of patients with a concern for multiple food allergies and to demonstrate an evidence-based approach to diagnosis and management. A literature search was performed and articles identified as relevant based on the search terms "food allergy," "food allergy diagnosis," "skin prick test," "serum IgE test," "oral food challenge", and "food allergy management." Patients at risk of food allergy are often misdiagnosed and appropriate evaluation of patients with concern for food allergy includes taking a thorough diet history and reaction history, performing specific tests intentionally and when indicated, and conducting an oral food challenge in a safe environment by an experienced provider when test results are inconclusive. An evidence-based approach to diagnosing and managing a patient at risk of having a life-threatening food allergy is reviewed.
Stereopsis testing without polarized glasses: a comparison study on five new stereoacuity tests.
Hatch, S W; Richman, J E
1994-09-01
Stereopsis testing is commonly used to assess the presence and level of binocular vision. A new series of stereopsis tests requiring no polarized goggles are available in the form of the Titmus Stereo Test, the Stereo Reindeer Test, the Random Dot Butterfly, the Random Dot Figures, and the Random E, Circle, Square. These polarized-free tests employ a special prismatic printing process creating a panagraphic presentation, i.e., a separate image is presented to each eye without the need for polarization. The purpose of this study was to compare the polarized-free stereo tests with their traditional polarized counterparts. Thirty four subjects, including several persons with strabismus, ages 10-35 years, were each tested with the polarized and polarized-free versions of the Titmus, Reindeer, Butterfly, and Figures. Twenty nine of these subjects were tested with the Random Dot E. Half the subjects were tested first with polarized-free and half were tested first with polarized tests. Tests were performed according to manufacturer instructions by the same examiner in clinical settings. The results (matched pair ranked correlation coefficients) indicate that the polarized-free tests were highly correlated (r = 0.997, r = 0.998, r = 0.997, r = 1.00, and r = 1.00 respectively) with the polarized comparison tests. No significant difference (Wilcoxon Ranked Sign) in the stereopsis level was obtained between the two versions of the tests. We conclude that these five polarized-free tests were just as valid in measuring the subjects' stereopsis as their traditional polarized version. The use of goggle-free testing has potential clinical advantages, e.g., testing of young children who will not wear the glasses or the improved observation of the ocular alignment during stereopsis testing.
Korošec, Peter; Šilar, Mira; Eržen, Renato; Čelesnik, Nina; Bajrović, Nissera; Zidarn, Mihaela; Košnik, Mitja
2013-01-01
Previous reports suggest the usefulness of basophil activation testing (BAT) in Hymenoptera-allergic patients with negative venom-specific IgE antibodies. We sought to evaluate the diagnostic utility of this testing in a routine clinical laboratory setting. Twenty-one patients with anaphylactic reactions to Hymenoptera sting (median grade III) and negative venom-specific IgE were routinely and prospectively tested with BAT. We were able to diagnose 81% (17 of 21) of patients with BAT and 57% (12 of 21) with intradermal skin testing. Three wasp venom-allergic patients showed IgE positivity to rVes v 5. Four patients (19%) were negative for all tests. In the case of double-positive BAT, the culprit insect correlated with the venom that induced a significantly higher basophil response. BAT allows the identification of severe Hymenoptera-allergic patients with negative specific IgE and skin tests. The routine use of this cellular test should facilitate prescription of venom immunotherapy in complex cases with inconclusive diagnostic results. Copyright © 2013 S. Karger AG, Basel.
Foong, Ru-Xin; Roberts, Graham; Fox, Adam Tobias; du Toit, George
2016-01-01
Children with atopic dermatitis (AD) are at risk of developing allergy. Alongside clinical history, testing modalities include skin prick tests (SPT), specific immunoglobulin-E (sp-IgE) and recently, microarray assays. The aim of this pilot study was to assess current tests and the ISAC sIgE-112 system in the diagnosis of food and aeroallergen allergy. Children aged 0-11 years with moderate to severe AD were included. An initial allergy assessment including clinical history, SPT and sp-IgE was performed to determine food and aeroallergen sensitization. A second independent clinical assessment using the same information given to the first assessor and ISAC test results for food and aeroallergen sensitization was also made for each participant. The results from both were compared. 30 children [mean age 3.91 years (SD 3.3)] were included; 53.3 and 46.7 % had moderate and severe AD, respectively. Sp-IgE tests had a higher percentage of positive results compared to SPT and ISAC tests for common allergens. There was a significant difference between the three tests in detecting aeroallergen sensitization (p = 0.038), especially between sp-IgE and ISAC tests, but no significant difference between the tests for food allergen sensitization. There was good agreement between the two assessors; 70 % of the children had a change in diagnosis, with 60 % having at least one diagnosis added and 40 % having at least one diagnosis removed. There is a role for the use of ISAC testing in diagnosing sensitization and allergy in children with AD as it leads to a change in diagnosis for many patients. Further work is required to assess its clinical and cost effectiveness.
Laboratory testing of the (Japan Storage Battery) traction batteries GS E75A and GS E150H
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This report describes the testing of the GS E75A and GS E150H flooded lead-acid 12-volt traction batteries and compares the selected batteries to U.S.-made electric vehicle batteries. The results and conclusions of the testing are presented.
1. Photographic copy of engineering drawing showing structure of Test ...
1. Photographic copy of engineering drawing showing structure of Test Stand 'B' (4215/E-16), also known as the 'Short Snorter.' California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Structural Addition - Bldg. E-12, Edwards Test Station,' drawing no. E12/1-1, 8 August 1957. - Jet Propulsion Laboratory Edwards Facility, Test Stand B, Edwards Air Force Base, Boron, Kern County, CA
2012-11-01
Research , Development, Test , and Evaluation (RDT&E) Appropriations The RDT&E appropriation consists of the mission program budgets for all... research , development, test and evaluation work performed by contractors and government installations and includes an installations and activities budget...than $4,000,000. 9 f. Research , Development, Test , and Evaluation Appropriations The Research , Development, Test , and Evaluation (RDT&E
Overview of T.E.S.T. (Toxicity Estimation Software Tool)
This talk provides an overview of T.E.S.T. (Toxicity Estimation Software Tool). T.E.S.T. predicts toxicity values and physical properties using a variety of different QSAR (quantitative structure activity relationship) approaches including hierarchical clustering, group contribut...
2015-08-01
Initial Operational Test and Evaluation ( IOT &E) and the system’s operational effectiveness, operational suitability, and cybersecurity. The Air Force...Operational Test and Evaluation Center (AFOTEC) conducted the IOT &E between October 1, 2014, and May 29, 2015, at seven bases that included three...at McConnell Air Force Base (AFB), Kansas. Adequacy of IOT &E The IOT &E was adequate and was executed in accordance with the Test and Evaluation
Bruno, M T; Ferrara, M; Fava, V; Barrasso, G; Panella, M M
2018-04-01
Human papillomavirus (HPV) testing is used in the triage of women with a borderline smear result. The efficiency of testing women with a low-grade squamous intraepithelial lesion (LSIL) and atypical squamous cells of undetermined significance (ASCUS) is less clear. For this reason we used a new HPV test that detects E6/E7 messenger RNA (mRNA), which might have a higher specificity. The objective of this prospective study was to assess whether HPV E6/E7 mRNA positivity in women with ASCUS and LSIL at baseline, is able to predict those women who have a high risk of developing a histological cervical intraepithelial neoplasia (CIN2) or worse lesion. We took into consideration the women's age and HPV DNA genotype and followed them up for 3 years. Cervical samples from women with high-risk HPV (HR-HPV) DNA-positive ASCUS (n = 90) or LSIL (n = 222) were tested for the presence of HR-HPV E6/E7 mRNA and the women were monitored for the development of histopathologically verified CIN2+. Thirteen patients with ASCUS and 17 with LSIL did not complete follow-up. All patients with LSIL and ASCUS, enrolled in this study, had confirmed lesions at the colposcopic examination. Follow-up was available for 312 women, 193 were positive in the HR-HPV DNA test and 93 had a HPV E6/E7 mRNA positive test. Finally, 22 women positive in the HPV DNA test for high-risk genotypes and with positive E6/E7 mRNA had a histologically confirmed CIN2+. Only two cases with negative HPV E6/E7 mRNA had CIN2+. The study shows that women positive in the HPV E6/E7 mRNA test have a greater risk of malignant progression of cervical lesions and therefore deserve greater attention and earlier check-ups.
40 CFR 91.411 - Post-test analyzer procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Post-test analyzer procedures. 91.411... Post-test analyzer procedures. (a) Perform a hang-up check within 60 seconds of the completion of the... and record the post-test data specified in § 91.405(e). (e) For a valid test, the analyzer drift...
40 CFR 91.411 - Post-test analyzer procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Post-test analyzer procedures. 91.411... Post-test analyzer procedures. (a) Perform a hang-up check within 60 seconds of the completion of the... and record the post-test data specified in § 91.405(e). (e) For a valid test, the analyzer drift...
40 CFR 91.411 - Post-test analyzer procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Post-test analyzer procedures. 91.411... Post-test analyzer procedures. (a) Perform a hang-up check within 60 seconds of the completion of the... and record the post-test data specified in § 91.405(e). (e) For a valid test, the analyzer drift...
40 CFR 91.411 - Post-test analyzer procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Post-test analyzer procedures. 91.411... Post-test analyzer procedures. (a) Perform a hang-up check within 60 seconds of the completion of the... and record the post-test data specified in § 91.405(e). (e) For a valid test, the analyzer drift...
40 CFR 91.411 - Post-test analyzer procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Post-test analyzer procedures. 91.411... Post-test analyzer procedures. (a) Perform a hang-up check within 60 seconds of the completion of the... and record the post-test data specified in § 91.405(e). (e) For a valid test, the analyzer drift...
2012-11-08
Jason Hopper of NASA (front row), Jody Ladner of Lockheed Martin (back row, left) and Chris Mulkey of NASA prepare to test the Blue Origin BE-3 engine thrust chamber in the E-1 Test Stand Control Center at John C. Stennis Space Center on Nov. 8. The test was one of 27 conducted in Stennis' E Test Complex the week of Nov. 5.
Measuring College Students' Reading Comprehension Ability Using Cloze Tests
ERIC Educational Resources Information Center
Williams, Rihana Shiri; Ari, Omer; Santamaria, Carmen Nicole
2011-01-01
Recent investigations challenge the construct validity of sustained silent reading tests. Performance of two groups of post-secondary students (e.g. struggling and non-struggling) on a sustained silent reading test and two types of cloze test (i.e. maze and open-ended) was compared in order to identify the test format that contributes greater…
49 CFR 40.23 - What actions do employers take after receiving verified test results?
Code of Federal Regulations, 2014 CFR
2014-10-01
...., random test, post-accident test) and DOT Agency (e.g., check DOT and FMCSA) as for the original... an employer who receives a cancelled test result when a negative result is required (e.g., pre... verified test results? 40.23 Section 40.23 Transportation Office of the Secretary of Transportation...
49 CFR 40.23 - What actions do employers take after receiving verified test results?
Code of Federal Regulations, 2010 CFR
2010-10-01
...., random test, post-accident test) and DOT Agency (e.g., check DOT and FMCSA) as for the original... an employer who receives a cancelled test result when a negative result is required (e.g., pre... verified test results? 40.23 Section 40.23 Transportation Office of the Secretary of Transportation...
1992-02-01
467 Table 4 Personal Items from Shovel Tests, 160R130. SURF SURF SURF N15 N5 NO NO $5 S5 1 2 3 W20 El5 E20 W10 E20 EO Bone button, Type B-5 Ceramic...Table 4 . Personal Items from Shovel Tests, 160R130. S15 S20 S20 S25 S25 S30 S30 S30 S32.5 E5 E35 E20 E50 E25 E50 E35 E20 E35 Bone button, Type B-5...1 1 1 7 1 471 Table 4 Personal Items from Shovel Tests, 160R130. S30 S34 S35 S45 S50 TOTAL El0 E35 E30 E30 E55 Bone button, Type B-5 1 1 Ceramic
Code of Federal Regulations, 2014 CFR
2014-07-01
... Toxicity to Daphnia: ASTM E 729-96 (Reapproved 2007). 3. Toxicity to Plants (Algae): ASTM E 1218-04 e1 Test... (Algae): ASTM E 1218-04 e1 The following are the special conditions for C1, C2, C3, C4, C5, and C7.... Toxicity to Plants (Algae): ASTM E 1218-04 e1 Test Group 2 for C2: 1. Chronic Toxicity to Daphnia: ASTM E...
1985-10-31
692-2124 ;.-.. - 5o sL NN T- - R ,: E -# C-eAcE Date Teot Poat - Amplificatlon dO AttenaUio d 8. Horzontal ne/div I VerticalMV/divI Horizontal ne/div...Vertical mV/div I Horizontal ne/div 2 *Vertical no/dIv 2 Configuration Pulter Level Data Link Comments: SI -. VI DateTo.t.o t, -~. e .4...2 Vertical ne/div 2 Configuration Pulser Level / V Date Linkt Comment:7 "- e "-’ DateG - - Test Point CH~f Amplification dB Attenataion .2 D) d 8
NASA Technical Reports Server (NTRS)
Pazos, John T.; Chandler, Craig A.; Raines, Nickey G.
2009-01-01
This paper will provide the reader a broad overview of the current upgraded capabilities of NASA's John C. Stennis Space Center E-3 Test Facility to perform testing for rocket engine combustion systems and components using liquid and gaseous oxygen, gaseous and liquid methane, gaseous hydrogen, hydrocarbon based fuels, hydrogen peroxide, high pressure water and various inert fluids. Details of propellant system capabilities will be highlighted as well as their application to recent test programs and accomplishments. Data acquisition and control, test monitoring, systems engineering and test processes will be discussed as part of the total capability of E-3 to provide affordable alternatives for subscale to full scale testing for many different requirements in the propulsion community.
Are independent probes truly independent?
Camp, Gino; Pecher, Diane; Schmidt, Henk G; Zeelenberg, René
2009-07-01
The independent cue technique has been developed to test traditional interference theories against inhibition theories of forgetting. In the present study, the authors tested the critical criterion for the independence of independent cues: Studied cues not presented during test (and unrelated to test cues) should not contribute to the retrieval process. Participants first studied a subset of cues (e.g., rope) that were subsequently studied together with a target in a 2nd study phase (e.g., rope-sailing, sunflower-yellow). In the test phase, an extralist category cue (e.g., sports, color) was presented, and participants were instructed to recall an item from the study list that was a member of the category (e.g., sailing, yellow). The experiments showed that previous study of the paired-associate word (e.g., rope) enhanced category cued recall even though this word was not presented at test. This experimental demonstration of covert cuing has important implications for the effectiveness of the independent cue technique.
Fuel Economy and Emissions of a Vehicle Equipped with an Aftermarket Flexible-Fuel Conversion Kit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, John F; Huff, Shean P; West, Brian H
2012-04-01
The U.S. Environmental Protection Agency (EPA) grants Certificates of Conformity for alternative fuel conversion systems and also offers other forms of premarket registration of conversion kits for use in vehicles more than two model years old. Use of alternative fuels such as ethanol, natural gas, and propane are encouraged by the Energy Policy Act of 1992. Several original equipment manufacturers (OEMs) produce emissions-certified vehicles capable of using alternative fuels, and several alternative fuel conversion system manufacturers produce EPA-approved conversion systems for a variety of alternative fuels and vehicle types. To date, only one manufacturer (Flex Fuel U.S.) has received EPAmore » certifications for ethanol fuel (E85) conversion kits. This report details an independent evaluation of a vehicle with a legal installation of a Flex Fuel U.S. conversion kit. A 2006 Dodge Charger was baseline tested with ethanol-free certification gasoline (E0) and E20 (gasoline with 20 vol % ethanol), converted to flex-fuel operation via installation of a Flex Box Smart Kit from Flex Fuel U.S., and retested with E0, E20, E50, and E81. Test cycles included the Federal Test Procedure (FTP or city cycle), the highway fuel economy test (HFET), and the US06 test (aggressive driving test). Averaged test results show that the vehicle was emissions compliant on E0 in the OEM condition (before conversion) and compliant on all test fuels after conversion. Average nitrogen oxide (NOx) emissions exceeded the Tier 2/Bin 5 intermediate life NO{sub X} standard with E20 fuel in the OEM condition due to two of three test results exceeding this standard [note that E20 is not a legal fuel for non-flexible-fuel vehicles (non-FFVs)]. In addition, one E0 test result before conversion and one E20 test result after conversion exceeded the NOX standard, although the average result in these two cases was below the standard. Emissions of ethanol and acetaldehyde increased with increasing ethanol, while nonmethane organic gas and CO emissions remained relatively unchanged for all fuels and cycles. Higher fraction ethanol blends appeared to decrease NO{sub X} emissions on the FTP and HFET (after conversion). As expected, fuel economy (miles per gallon) decreased with increasing ethanol content in all cases.« less
Saulite, Ieva; Hoetzenecker, Wolfram; Guenova, Emmanuella; Schmid-Grendelmeier, Peter; Glatz, Martin
2017-01-01
Skin test reactivity to hymenoptera venom and venom-specific IgE are important for diagnosing venom allergy and deciding on the appropriate allergen for venom immunotherapy (VIT). Longitudinal data on skin test reactivity during VIT and their correlation with venom-specific immunoglobulin (Ig)E and IgG are scarce. We retrospectively analyzed shifts in skin test reactivity and serum levels of venom-specific IgE and IgG in patients allergic to hymenoptera venom before the initiation of VIT with ultrarush therapy and after ≥3 years of VIT. Fifty-four patients received ultrarush desensitization and subsequent VIT with wasp venom, 26 with honeybee venom, and 8 with both wasp and honeybee venom. Hymenoptera-specific skin test reactivity decreased during VIT in most patients, and became negative in 8% of the wasp-allergic patients and in 25% of the honeybee-allergic patients. Serum levels of venom-specific IgE positively correlated to skin test reactivity before VIT, but did not change significantly during VIT. IgG serum levels and the IgG/IgE ratio increased during VIT in most patients. A high IgG/IgE ratio correlated with low skin test reactivity after ≥3 years of VIT. The correlation between a high venom-specific IgG/IgE ratio and low skin test reactivity after VIT may be interesting for future investigations that assess its role as a potential marker for VIT efficacy. © 2017 S. Karger AG, Basel.
Northwest Manufacturing Initiative
2013-03-26
Testing of Metallic Materials] specifications. For high temperature tests, a heated water bath was use while for low temperature testing down to...Weld metal and heat affected zones were evaluated using Charpy and E399 fracture toughness methods. The influence of temperature , loading rate, CVN...determine the influence of fracture test methods and welding procedures on toughness. Room temperature E399 tests, (CTS) were carried out under
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-27
... (the checkmark can pre-printed in the appropriate box on the CCF at Step 1-D). (h) Test reason, as appropriate: Pre-employment; Random; Reasonable Suspicion/Reasonable Cause; Post-Accident; Return-to-Duty; and... reason (e.g., random test, post-accident test) and DOT Agency (e.g., check DOT and FMCSA) as for the...
Adaptive linear rank tests for eQTL studies
Szymczak, Silke; Scheinhardt, Markus O.; Zeller, Tanja; Wild, Philipp S.; Blankenberg, Stefan; Ziegler, Andreas
2013-01-01
Expression quantitative trait loci (eQTL) studies are performed to identify single-nucleotide polymorphisms that modify average expression values of genes, proteins, or metabolites, depending on the genotype. As expression values are often not normally distributed, statistical methods for eQTL studies should be valid and powerful in these situations. Adaptive tests are promising alternatives to standard approaches, such as the analysis of variance or the Kruskal–Wallis test. In a two-stage procedure, skewness and tail length of the distributions are estimated and used to select one of several linear rank tests. In this study, we compare two adaptive tests that were proposed in the literature using extensive Monte Carlo simulations of a wide range of different symmetric and skewed distributions. We derive a new adaptive test that combines the advantages of both literature-based approaches. The new test does not require the user to specify a distribution. It is slightly less powerful than the locally most powerful rank test for the correct distribution and at least as powerful as the maximin efficiency robust rank test. We illustrate the application of all tests using two examples from different eQTL studies. PMID:22933317
Adaptive linear rank tests for eQTL studies.
Szymczak, Silke; Scheinhardt, Markus O; Zeller, Tanja; Wild, Philipp S; Blankenberg, Stefan; Ziegler, Andreas
2013-02-10
Expression quantitative trait loci (eQTL) studies are performed to identify single-nucleotide polymorphisms that modify average expression values of genes, proteins, or metabolites, depending on the genotype. As expression values are often not normally distributed, statistical methods for eQTL studies should be valid and powerful in these situations. Adaptive tests are promising alternatives to standard approaches, such as the analysis of variance or the Kruskal-Wallis test. In a two-stage procedure, skewness and tail length of the distributions are estimated and used to select one of several linear rank tests. In this study, we compare two adaptive tests that were proposed in the literature using extensive Monte Carlo simulations of a wide range of different symmetric and skewed distributions. We derive a new adaptive test that combines the advantages of both literature-based approaches. The new test does not require the user to specify a distribution. It is slightly less powerful than the locally most powerful rank test for the correct distribution and at least as powerful as the maximin efficiency robust rank test. We illustrate the application of all tests using two examples from different eQTL studies. Copyright © 2012 John Wiley & Sons, Ltd.
Critical Review of the ECSS-E-ST-20-07C ESD Test Set-Up for Testing Spacecraft Equipment
NASA Astrophysics Data System (ADS)
Pelissou, P.; Daout, B.; Romero, C.; Wolf, K.-F. J.
2016-05-01
Satellite equipment needs to be immune to electrostatic discharges (ESD) likely to occur in flight. Testing the susceptibility against ESD on spacecraft equipment is therefore an important part of the EMC test program. The test method according to ECSS-E-ST- 20-07C [1], which is commonly used in space industry, leaves undesirable degrees of freedom on how the test is performed, which in turn has an influence on the injected current and therefore on the test results. Because of the indirect coupling of ESD to circuits, the current waveform applied during the test and its repeatability are of high importance. In the frame of an ESTEC research contract (4000109887/13/NL/GLC), a critical review of the ECSS-E-ST-20-07C is performed to identify the influence factors which have an impact on the test repeatability.
Positive Skin Test or Specific IgE to Penicillin Does Not Reliably Predict Penicillin Allergy.
Tannert, Line Kring; Mortz, Charlotte Gotthard; Skov, Per Stahl; Bindslev-Jensen, Carsten
According to guidelines, patients are diagnosed with penicillin allergy if skin test (ST) result or specific IgE (s-IgE) to penicillin is positive. However, the true sensitivity and specificity of these tests are presently not known. To investigate the clinical relevance of a positive ST result and positive s-IgE and to study the reproducibility of ST and s-IgE. A sample of convenience of 25 patients with positive penicillin ST results, antipenicillin s-IgE results, or both was challenged with their culprit penicillin. Further 19 patients were not challenged, but deemed allergic on the basis of a recent anaphylactic reaction or delayed reactions to skin testing. Another sample of convenience of 18 patients, 17 overlapping with the 25 challenged, with initial skin testing and s-IgE (median, 25; range, 3-121), months earlier (T -1 ), was repeat skin tested and had s-IgE measured (T 0 ), and then skin tested and had s-IgE measured 4 weeks later (T 1 ). Only 9 (36%) of 25 were challenge positive. There was an increased probability of being penicillin allergic if both ST result and s-IgE were positive at T 0 . Positive ST result or positive s-IgE alone did not predict penicillin allergy. Among the 18 patients repeatedly tested, 46.2% (12 of 25) of positive ST results at T -1 were reproducibly positive at T 0 . For s-IgE, 54.2% (14 of 24) positive measurements were still positive at T 0 and 7 converted to positive at T 1 . The best predictor for a clinically significant (IgE-mediated) penicillin allergy is a combination of a positive case history with simultaneous positive ST result and s-IgE or a positive challenge result. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Yoshida, Naruo; Hirata, Hirokuni; Watanabe, Mineaki; Sugiyama, Kumiya; Arima, Masafumi; Fukushima, Yasutsugu; Ishii, Yoshiki
2015-07-01
Ves v 5 and Pol d 5, which constitute antigen 5, are recognized as the major, most potent allergens of family Vespidae. Several studies have reported the diagnostic sensitivity of the novel recombinant (r)Ves v 5 and rPol d 5 allergens in routine clinical laboratory settings by analyzing a group of Vespula and Polistes venom-allergic patients. In this study, we analyzed the sensitivity to venom specific (s)IgE by spiking with rVes v 5 and rPol d 5 in Japanese patients suspected of Hymenoptera venom allergy. Subjects were 41 patients who had experienced systemic reactions to hornet and/or paper wasp stings. Levels of serum sIgE against hornet and paper wasp venom by spiking with rVes v 5 and rPold d 5, respectively, as improvement testing, compared with hornet and paper wasp venom, as conventional testing, were measured by ImmunoCAP. Of the 41 patients, 33 (80.5%) were positive (≥0.35 UA/ml) for hornet and/or paper wasp venom in conventional sIgE testing. sIgE levels correlated significantly (P < 0.01) between hornet (R = 0.92) or paper wasp venom (R = 0.78) in improvement testing and conventional testing. To determine specificity, 20 volunteers who had never experienced a Hymenoptera sting were all negative for sIgE against these venoms in both improvement and conventional testing. Improved sensitivity was seen in 8 patients negative for sIgE against both venoms in conventional testing, while improvement testing revealed sIgE against hornet or paper wasp venom in 5 (total 38 (92.7%)) patients. The measurement of sIgE following spiking of rVes v 5 and rPol d 5 by conventional testing in Japanese subjects with sIgE against hornet and paper wasp venom, respectively, improved the sensitivity for detecting Hymenoptera venom allergy. Improvement testing for measuring sIgE levels against hornet and paper wasp venom has potential for serologically elucidating Hymenoptera allergy in Japan. Copyright © 2015 Japanese Society of Allergology. Production and hosting by Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Acute Toxicity to Daphnia: ASTM E 729 3. Toxicity to Plants (Algae): ASTM E 1218 Test Group 2 for C1: 1. Chronic Toxicity to Daphnia: ASTM E 1193 2. Toxicity to Plants (Algae): ASTM E 1218 The following are the... conditions. Test Group 1 for C2: 1. Acute Toxicity to Daphnia: ASTM E 729 2. Toxicity to Plants (Algae): ASTM...
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Acute Toxicity to Daphnia: ASTM E 729 3. Toxicity to Plants (Algae): ASTM E 1218 Test Group 2 for C1: 1. Chronic Toxicity to Daphnia: ASTM E 1193 2. Toxicity to Plants (Algae): ASTM E 1218 The following are the... conditions. Test Group 1 for C2: 1. Acute Toxicity to Daphnia: ASTM E 729 2. Toxicity to Plants (Algae): ASTM...
... Mumps Tests MPV Blood Test Mucus in Urine N Nitrites in Urine P Pap Smear Porphyrin Test ... V Vitamin D Test Vitamin E (tocopherol) Test Y Yeast Infection Test Related MedlinePlus Health Topics Laboratory ...
2. Photographic copy of engineering drawing showing mechanical systems in ...
2. Photographic copy of engineering drawing showing mechanical systems in plan and sections of Test Stand 'E,' including tunnel entrance. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Bldg. E-60 Mechanical, Solid Propellant Test Stand,' sheet E60/13-4, June 20, 1961. - Jet Propulsion Laboratory Edwards Facility, Test Stand E, Edwards Air Force Base, Boron, Kern County, CA
Lee, Posen; Lu, Wen-Shian; Liu, Chin-Hsuan; Lin, Hung-Yu; Hsieh, Ching-Lin
2017-12-08
The d2 Test of Attention (D2) is a commonly used measure of selective attention for patients with schizophrenia. However, its test-retest reliability and minimal detectable change (MDC) are unknown in patients with schizophrenia, limiting its utility in both clinical and research settings. The aim of the present study was to examine the test-retest reliability and MDC of the D2 in patients with schizophrenia. A rater administered the D2 on 108 patients with schizophrenia twice at a 1-month interval. Test-retest reliability was determined through the calculation of the intra-class correlation coefficient (ICC). We also carried out Bland-Altman analysis, which included a scatter plot of the differences between test and retest against their mean. Systematic biases were evaluated by use of a paired t-test. The ICCs for the D2 ranged from 0.78 to 0.94. The MDCs (MDC%) of the seven subscores were 102.3 (29.7), 19.4 (85.0), 7.2 (94.6), 21.0 (69.0), 104.0 (33.1), 105.0 (35.8), and 7.8 (47.8), which represented limited-to-acceptable random measurement error. Trends in the Bland-Altman plots of the omissions (E1), commissions (E2), and errors (E) were noted, presenting that the data had heteroscedasticity. According to the results, the D2 had good test-retest reliability, especially in the scores of TN, TN-E, and CP. For the further research, finding a way to improve the administration procedure to reduce random measurement error would be important for the E1, E2, E, and FR subscores. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
7. Credit BG. View looking west into small solid rocket ...
7. Credit BG. View looking west into small solid rocket motor testing bay of Test Stand 'E' (Building 4259/E-60). Motors are mounted on steel table and fired horizontally toward the east. - Jet Propulsion Laboratory Edwards Facility, Test Stand E, Edwards Air Force Base, Boron, Kern County, CA
21 CFR 866.5510 - Immunoglobulins A, G, M, D, and E immunological test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... test system. 866.5510 Section 866.5510 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test Systems § 866.5510 Immunoglobulins A, G, M, D, and E immunological test system. (a) Identification...
29 CFR 1926.97 - Electrical protective equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... glove. (2) Electrical requirements. (i) Equipment shall be capable of withstanding the ac proof-test voltage specified in Table E-1 or the dc proof-test voltage specified in Table E-2. (A) The proof test shall reliably indicate that the equipment can withstand the voltage involved. (B) The test voltage...
40 CFR 790.50 - Submission of study plans.
Code of Federal Regulations, 2013 CFR
2013-07-01
... no letter of intent to conduct the test had been submitted as described in § 790.45(e) and (f). (e... CONTROL ACT (CONTINUED) PROCEDURES GOVERNING TESTING CONSENT AGREEMENTS AND TEST RULES Implementation, Enforcement, and Modification of Test Rules § 790.50 Submission of study plans. (a) Who must submit study...
40 CFR 790.50 - Submission of study plans.
Code of Federal Regulations, 2012 CFR
2012-07-01
... no letter of intent to conduct the test had been submitted as described in § 790.45(e) and (f). (e... CONTROL ACT (CONTINUED) PROCEDURES GOVERNING TESTING CONSENT AGREEMENTS AND TEST RULES Implementation, Enforcement, and Modification of Test Rules § 790.50 Submission of study plans. (a) Who must submit study...
40 CFR 790.50 - Submission of study plans.
Code of Federal Regulations, 2014 CFR
2014-07-01
... no letter of intent to conduct the test had been submitted as described in § 790.45(e) and (f). (e... CONTROL ACT (CONTINUED) PROCEDURES GOVERNING TESTING CONSENT AGREEMENTS AND TEST RULES Implementation, Enforcement, and Modification of Test Rules § 790.50 Submission of study plans. (a) Who must submit study...
MHD generator electrode development. Summary report, July 1, 1981-September 30, 1982
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rossing, B.R.; Buckman, R.W. Jr.; Pouchot, W.D.
Emphasis on this program was the development of and understanding wastage mechanism(s) of metallic electrodes which may be suitable alternatives to platinum anode material for use in long-term open cycle, coal-fired MHD generator operations. The laboratory tests simulate both modes of material wastage observed in MHD electrode operation; i.e., arc erosion (melting/vaporization) and electrochemical corrosion. Based on experimental results from the electrochemical tests at 1473/sup 0/K, the rank order listing of the materials tested for anode applications were platinum, E-Brite 26-1 modified with a five percent addition of platinum, chromium, IN 601, E-Brite 26-1, and 330 stainless steel ranked inmore » decreasing order. The rank order listing based on the arc erosion test was platinum, chromium, E-Brite 26-1, 330 stainless steel, and IN 601. The relative arc erosion resistance of materials based on the AVCO Mark VII generator test results gave a rank order of platinum, 330 stainless steel, IN 601, and E-Brite 26-1. Engineering tests under simulated open-cycle coal-fired MHD operating conditions were performed in the 500 kW Westinghouse Electrode System Test Facility (WESTF). Tests were conducted on candidate metallic anode materials (cold wall) and ceramic anode (hot wall) materials. A ten-hour duration cold wall slagging test was conducted on platinum, E-Brite 26-1, 330 stainless steel and IN 601 and the results were similar to those obtained for those materials in the AVCO Mark VII generator tests. Non-slagging, super hot (>1700/sup 0/C) wall hafnia-rare earth oxide electrodes were tested in a sulfurous, western coal-fired MHD environment. All four ceramic electrode pairs were destroyed. 20 references.« less
Officer Career Development: Longitudinal Sample--Fiscal Years 1986-1987
1991-10-01
XO-Fleet Replacement Squadron (RAG) 4. CO-Fleet Replacement Squadron (RAG) 5. Test Pilot School 6. Washington Tour 7. Wing Staff 8. Naval Aviation...2535 4. CO -RAG E9E6 - - - - - - - 1 2536 5. Test Pilot E9E7 - - - - - - - 1 2537 6. Wash. Tour E9E9 - - - - - - - 1 2538 1. Wing Staff E9E1O - 2539...for department head (VP community only) 12. Screening for Test Pilot school (omit if not applicable) RESPONSE SCALE: 1. Little Or No Change 2. 3. A
Materiel Testing in the Tropics (6th Ed)
1979-04-01
ceramics Test methodology Panama Canal Zone Textiles Plastics Tropic Test Center Protective coatings Tropical animals 20. (cont) of Materiel Testing in...Canal Zone . .. 1-3 D Materiel Testing in the Panama Canal Zone . . . . . . . ... . 1-5 E Canal Zone Environment--Brief Overview .. .. .... ...... 1-6...trapped there, and by the heavy biomass of the canopy itself. E. CANAL ZONE ENVIRONMENT--BRIEF OVERVIEW The Canal Zone (see frontispiece) bisects the
NASA Astrophysics Data System (ADS)
Masocha, Willias; Kombian, Samuel B.; Edafiogho, Ivan O.
2016-02-01
Recently, we found that methyl 4-(4‧-bromophenyl)aminocyclohex-3-en-6-methyl-2-oxo-1-oate (E139), an anticonvulsant enaminone, has antinociceptive activity in the hot plate test. In this study we evaluated the antinociceptive activity of five anilino enaminones E139, ethyl 4-(4‧-chlorophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (E121), ethyl 4-(4‧-bromophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (E122), methyl 4-(4‧-chlorophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (E138) and ethyl 4-(4‧-fluorophenyl)amino-6-methyl-2-oxocyclohex-3-en-1-oate (BRG 19) using the formalin and hot plate tests. E139 has been reported to exert its effects via enhancement of extracellular GABA levels, thus tiagabine, a GABA transporter inhibitor, was evaluated as a control together with indomethacin. Tiagabine had antinociceptive activity in both phase 1 (neurogenic pain) and phase 2 (inflammatory pain) of the formalin test, whereas indomethacin had activity only in phase 2. E139 and E138 had antinociceptive activity in both phases of the formalin test, whereas E121 had activity only in phase 1 and BRG 19 had activity only in phase 2. E122 had no significant activity in either phase. In the hot plate test only E139 had antinociceptive activity. Administration of either bicuculline, a GABAA receptor antagonist, or CGP 35348, a GABAB receptor antagonist, blocked the antinociceptive activity of E139. In conclusion our results indicate that E139 has antinociceptive activity in the formalin and hot plate tests that are dependent on GABA receptors.
Afroundeh, R; Arimitsu, T; Yamanaka, R; Lian, C S; Shirakawa, K; Yunoki, T; Yano, T
2014-01-01
Time delay in the mediation of ventilation (V(.)E) by arterial CO(2) pressure (PaCO(2)) was studied during recovery from short impulse-like exercises with different work loads of recovery. Subjects performed two tests including 10-s impulse like exercise with work load of 200 watts and 15-min recovery with 25 watts in test one and 50 watts in test two. V(.)E, end tidal CO(2) pressure (PETCO(2)) and heart rate (HR) were measured continuously during rest, warming up, exercise and recovery. PaCO(2) was estimated from PETCO(2) and tidal volume (V(T)). Results showed that predicted arterial CO(2) pressure (PaCO(2 pre)) increased during recovery in both tests. In both tests, V(.)E increased and peaked at the end of exercise. V(.)E decreased in the first few seconds of recovery but started to increase again. The highest correlation coefficient between PaCO(2 pre) and V(.)E was obtained in the time delay of 7 s (r=0.854) in test one and in time delays of 6 s (r=0.451) and 31 s (r=0.567) in test two. HR was significantly higher in test two than in test one. These results indicate that PaCO(2 pre) drives V(.)E with a time delay and that higher work intensity induces a shorter time delay.
Persson, Maria; Elfström, K Miriam; Brismar Wendel, Sophia; Weiderpass, Elisabete; Andersson, Sonia
2014-01-01
Expression of the viral E6/E7 oncogenes of high-risk human papillomaviruses (HR-HPV) is necessary for malignant conversion and maintenance in cervical tissue. In order to determine whether HR-HPV E6/E7 mRNA testing more effectively predicts precancerous lesions and invasive cervical cancer than HR-HPV DNA testing, we aimed to compare triage using HR-HPV E6/E7 mRNA testing by APTIMA HPV Assay (APTIMA) to HPV16 DNA testing, HPV16/18 DNA testing, and repeat cytology. Liquid-based (PreservCyt) cell samples were obtained from HR-HPV-positive women diagnosed with atypical squamous cells of undetermined significance (ASCUS) and low-grade squamous intraepithelial lesions (LSIL) within the framework of the population-based cervical cancer screening program in Stockholm, Sweden. Samples were tested for HR-HPV E6/E7 mRNA by APTIMA (Gene-Probe Inc., San Diego, CA, USA). Women were followed up for 4 years after the index cytology via medical and laboratory records, and the Stockholm Oncology Center. Nine of 25 (36%) women in the ASCUS group, and 64 of 180 (36%) women in the LSIL group developed cervical intraepithelial neoplasia (CIN) grade 2 or worse during 4 years of follow-up. 162 (74%) women were APTIMA-positive, and APTIMA had the highest sensitivity to predict CIN2 or worse and CIN3 or worse in the ASCUS (77.8% and 100%) and LSIL (78.1 and 75.8%) groups, although specificity was insufficient (<50%). HPV16 DNA testing and repeat cytology were more specific than APTIMA. The results of this population-based study with comprehensive follow-up support the use of APTIMA as a triage test for women with ASCUS. More focused investigation is required for women with LSIL.
Persson, Maria; Elfström, K. Miriam; Brismar Wendel, Sophia; Weiderpass, Elisabete; Andersson, Sonia
2014-01-01
Objective Expression of the viral E6/E7 oncogenes of high-risk human papillomaviruses (HR-HPV) is necessary for malignant conversion and maintenance in cervical tissue. In order to determine whether HR-HPV E6/E7 mRNA testing more effectively predicts precancerous lesions and invasive cervical cancer than HR-HPV DNA testing, we aimed to compare triage using HR-HPV E6/E7 mRNA testing by APTIMA HPV Assay (APTIMA) to HPV16 DNA testing, HPV16/18 DNA testing, and repeat cytology. Methods Liquid-based (PreservCyt) cell samples were obtained from HR-HPV-positive women diagnosed with atypical squamous cells of undetermined significance (ASCUS) and low-grade squamous intraepithelial lesions (LSIL) within the framework of the population-based cervical cancer screening program in Stockholm, Sweden. Samples were tested for HR-HPV E6/E7 mRNA by APTIMA (Gene-Probe Inc., San Diego, CA, USA). Women were followed up for 4 years after the index cytology via medical and laboratory records, and the Stockholm Oncology Center. Results Nine of 25 (36%) women in the ASCUS group, and 64 of 180 (36%) women in the LSIL group developed cervical intraepithelial neoplasia (CIN) grade 2 or worse during 4 years of follow-up. 162 (74%) women were APTIMA-positive, and APTIMA had the highest sensitivity to predict CIN2 or worse and CIN3 or worse in the ASCUS (77.8% and 100%) and LSIL (78.1 and 75.8%) groups, although specificity was insufficient (<50%). HPV16 DNA testing and repeat cytology were more specific than APTIMA. Conclusion The results of this population-based study with comprehensive follow-up support the use of APTIMA as a triage test for women with ASCUS. More focused investigation is required for women with LSIL. PMID:24587193
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hilbert, D.
2011-10-01
Three Mercury Marine outboard marine engines were evaluated for durability using E15 fuel -- gasoline blended with 15% ethanol. Direct comparison was made to operation on E0 (ethanol-free gasoline) to determine the effects of increased ethanol on engine durability. Testing was conducted using a 300-hour wide-open throttle (WOT) test protocol, a typical durability cycle used by the outboard marine industry. Use of E15 resulted in reduced CO emissions, as expected for open-loop, non-feedback control engines. HC emissions effects were variable. Exhaust gas and engine operating temperatures increased as a consequence of leaner operation. Each E15 test engine exhibited some deteriorationmore » that may have been related to the test fuel. The 9.9 HP, four-stroke E15 engine exhibited variable hydrocarbon emissions at 300 hours -- an indication of lean misfire. The 300HP, four-stroke, supercharged Verado engine and the 200HP, two-stroke legacy engine tested with E15 fuel failed to complete the durability test. The Verado engine failed three exhaust valves at 285 endurance hours while the 200HP legacy engine failed a main crank bearing at 256 endurance hours. All E0-dedicated engines completed the durability cycle without incident. Additional testing is necessary to link the observed engine failures to ethanol in the test fuel.« less
Sajedi, Vahid; Movahedi, Masoud; Aghamohammadi, Asghar; Aghamohamadi, Asghar; Gharagozlou, Mohammad; Ghareguzlou, Mohammad; Shafiei, Alireza; Soheili, Habib; Sanajian, Nahal
2011-06-01
Intradermal injection of autologous serum and plasma elicit a cutaneous reactivity in almost 45-60% of patients with Chronic Idiopathic Urticaria (CIU). This reactivity is associated with the presence of auto antibodies against IgE or IgE receptors. This study was carried out to compare the cutaneous reactivity of autologous serum and plasma skin tests in a series of patients with CIU for diagnosis of auto antibodies against IgE or IgE receptor. Fifty eight patients with CIU were injected intradermally with autologous serum and plasma (anticoagulated by citrate). Histamine was used as positive control and normal saline as negative control. The study group was checked by routine laboratory tests (CBC, U/A etc), allergens with skin prick tests, and serum IgE level, and auto antibodies against thyroid as well. Duration of urticaria was another factor which was assessed.There was no significant difference between positive ASST and positive APST patients for the above mentioned tests. 77.6% of the patients were Positive for APST and 65.5% were ASST positive. Duration of urticaria was longer in patients with positive ASST and APST than ASST and APST negative patients, although the difference was not statistically significant.Autologus serum skin test (ASST) and autologous plasma skin test (APST) could be used for estimation of duration and severity of urticaria and planning for the treatment.
Design Authority in the Test Programme Definition: The Alenia Spazio Experience
NASA Astrophysics Data System (ADS)
Messidoro, P.; Sacchi, E.; Beruto, E.; Fleming, P.; Marucchi Chierro, P.-P.
2004-08-01
In addition, being the Verification and Test Programme a significant part of the spacecraft development life cycle in terms of cost and time, very often the subject of the mentioned discussion has the objective to optimize the verification campaign by possible deletion or limitation of some testing activities. The increased market pressure to reduce the project's schedule and cost is originating a dialecting process inside the project teams, involving program management and design authorities, in order to optimize the verification and testing programme. The paper introduces the Alenia Spazio experience in this context, coming from the real project life on different products and missions (science, TLC, EO, manned, transportation, military, commercial, recurrent and one-of-a-kind). Usually the applicable verification and testing standards (e.g. ECSS-E-10 part 2 "Verification" and ECSS-E-10 part 3 "Testing" [1]) are tailored to the specific project on the basis of its peculiar mission constraints. The Model Philosophy and the associated verification and test programme are defined following an iterative process which suitably combines several aspects (including for examples test requirements and facilities) as shown in Fig. 1 (from ECSS-E-10). The considered cases are mainly oriented to the thermal and mechanical verification, where the benefits of possible test programme optimizations are more significant. Considering the thermal qualification and acceptance testing (i.e. Thermal Balance and Thermal Vacuum) the lessons learned originated by the development of several satellites are presented together with the corresponding recommended approaches. In particular the cases are indicated in which a proper Thermal Balance Test is mandatory and others, in presence of more recurrent design, where a qualification by analysis could be envisaged. The importance of a proper Thermal Vacuum exposure for workmanship verification is also highlighted. Similar considerations are summarized for the mechanical testing with particular emphasis on the importance of Modal Survey, Static and Sine Vibration Tests in the qualification stage in combination with the effectiveness of Vibro-Acoustic Test in acceptance. The apparent relative importance of the Sine Vibration Test for workmanship verification in specific circumstances is also highlighted. Fig. 1. Model philosophy, Verification and Test Programme definition The verification of the project requirements is planned through a combination of suitable verification methods (in particular Analysis and Test) at the different verification levels (from System down to Equipment), in the proper verification stages (e.g. in Qualification and Acceptance).
Test Report of Special Form Qualification Testing for the ORNL U ZipCan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, Oscar A.
This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSImore » N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.« less
1992-04-01
Manager, ARDE, INC. as Prime Contractor/Principal Investigator, Physics International as subcontractor for failure modeling computer calculations and Air...Force Astronautics Laboratory (EAFB) for full scale composite vessel testing. In addition, important contributions were made by Dr. Yen Pan...34 0 AND 22" 0 PSC VESSEL TESTS E-i E.1 - FULL SCALE COMPOSITE VESSEL E-1 TESTS - INSTRUMENTATION REQUIREMENTS/PROCEDURES E.2 - 16" 0 AND 22" 0 PSC
1992-01-01
SUBTmI.E 5 FU.NDING NUMBERS Job Performance Tests for CII-53E Helicopter Miechanacs - Volume I1: Admiutstrative Duties and Job Knowlede Tests C - N...performance measures to Marine Corps personnel managers . training instructors, and interested researchers who may find them useful. This work comprises...Corps personnel managers , training instructors, and interested researchers who may find them useful. 3. This work comprises two parts: volume I
2003-01-28
Proposal Title PORTABLE TEST CELL - JETCAL 2000(R) Lead Proposer HOWELL INSTRUMENTS Military Customer NAVY/MARINE H53...B-4 Proposal Title PORTABLE TEST CELL - JETCAL 2000(R) Lead Proposer HOWELL INSTRUMENTS Military Customer...TEST CELL - JETCAL 2000(R) Lead Proposer HOWELL INSTRUMENTS Military Customer NAVY/MARINE H53 AIRCRAFT Baseline Costs -- DoD’s Costs When COSSI is NOT
Code of Federal Regulations, 2010 CFR
2010-07-01
... serve its intended function for 1 hour when subjected to a fire test incorporating an ASTM E119-88 time/temperature heat input, or equivalent. The publication ASTM E119-88 “Standard Test Methods for Fire Tests of... for Testing Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA, 19428-2959...
Designing an Affordable Usability Test for E-Learning Modules
ERIC Educational Resources Information Center
O'Bryan, Corliss A.; Johnson, Donald M.; Shores-Ellis, Katrina D.; Crandall, Philip G.; Marcy, John A.; Seideman, Steve C.; Ricke, Steven C.
2010-01-01
This article provides background and an introduction to a user-centered design and usability test in an inexpensive format that allows content experts who are novices in e-learning development to perform testing on newly developed technical training modules prior to their release. The use of a small number of test participants, avoidance of…
40 CFR 86.1330-90 - Test sequence; general requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... fuel and the point at which it is measured shall be specified by the manufacturer. (g) Pre-test engine...-fueled or methanol-fueled diesel engine fuel flows, etc.), pre-test engine performance checks (e.g., verification of actual rated rpm, etc.) and pre-test system calibrations (e.g., inlet and exhaust restrictions...
40 CFR 86.1330-90 - Test sequence; general requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... fuel and the point at which it is measured shall be specified by the manufacturer. (g) Pre-test engine...-fueled or methanol-fueled diesel engine fuel flows, etc.), pre-test engine performance checks (e.g., verification of actual rated rpm, etc.) and pre-test system calibrations (e.g., inlet and exhaust restrictions...
40 CFR 86.1330-90 - Test sequence; general requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... fuel and the point at which it is measured shall be specified by the manufacturer. (g) Pre-test engine...-fueled or methanol-fueled diesel engine fuel flows, etc.), pre-test engine performance checks (e.g., verification of actual rated rpm, etc.) and pre-test system calibrations (e.g., inlet and exhaust restrictions...
40 CFR 86.1330-90 - Test sequence; general requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... fuel and the point at which it is measured shall be specified by the manufacturer. (g) Pre-test engine...-fueled or methanol-fueled diesel engine fuel flows, etc.), pre-test engine performance checks (e.g., verification of actual rated rpm, etc.) and pre-test system calibrations (e.g., inlet and exhaust restrictions...
Sewell, D L; Pfaller, M A; Barry, A L
1994-01-01
A comparison of the E test, the broth microdilution test, and the reference broth macrodilution susceptibility test of the National Committee for Clinical Laboratory Standards for fluconazole susceptibility testing was performed with 238 clinical isolates of Candida species and Torulopsis (Candida) glabrata. An 80% inhibition endpoint MIC was determined by the reference broth macrodilution method after 48 h of incubation. The MICs obtained by the two study methods were read after 24 and 48 h of incubation. Overall, excellent agreement within 2 doubling dilutions was obtained between the broth microdilution and the broth macrodilution methods for the combined results for all species at both 24 h (93%) and 48 h (94%). The correlation of 24-h MIC endpoints between the E test and the broth macrodilution methods was 37% for T. glabrata, 56% for Candida tropicalis, 93% for Candida albicans, and 90% for other Candida species. The percent agreement at 48 h ranged from 34% for T. glabrata to 97% for Candida species other than C. albicans and C. tropicalis. These initial results support the further evaluation of the E test as an alternative method for fluconazole susceptibility testing of Candida species. PMID:7814531
Low prevalence of hepatitis E in Iceland: a seroepidemiological study.
Löve, Arthur; Björnsdottir, Thora B; Olafsson, Sigurdur; Björnsson, Einar S
2018-03-01
Hepatitis E virus (HEV) infection has been reported to be more prevalent in the developed countries than previously thought. HEV infection is an important differential diagnosis in patients with drug-induced liver injury (DILI). The prevalence of hepatitis E was investigated in the general population of Iceland, among pig farmers and patients with DILI. Serum samples were tested for hepatitis E IgG, with two commercial ELISA tests: Diagnostic Bioprobes Srl. (Dia Pro) and the Wantai HEV IgG and subjects repeatedly reactive were tested with an immunoblot assay (RecomLINE). Three groups were tested: (1) healthy volunteers (HV), (2) pig farm workers (PFWs) and (3) patients participating in a nationwide prospective study on DILI. Overall 291 individuals were tested, HV (n = 195), PFW (n = 21) and DILI (n = 75). Only 6/291 (2.1%) tested positive for IgG antibodies to HEV in all three tests. Three HV were HEV IgG antibody positive and three in the DILI group. One PFW tested positive in the Dia Pro and Wantai tests but not in the immunoblot assay. All but one of the positive individuals in all three tests was either of foreign national origin or had spent extended period of time outside of Iceland. The seroprevalence of hepatitis E appears to be lower in Iceland than majority of recent studies in other western countries have demonstrated. This may be due to relative isolation and severe restriction on import of livestock from other countries.
Kuecuekbalaban, P; Schmidt, S; Muehlan, H
2018-03-01
The aim of the current study was to provide an overview of medical-diagnostic self-tests which can be purchased without a medical prescription on German language websites. From September 2014 to March 2015, a systematic internet research was conducted with the following search terms: self-test, self-diagnosis, home test, home diagnosis, quick test, rapid test. 513 different self-tests for the diagnostics of 52 diverse diseases or health risks were identified, including chronic diseases (e. g. diabetes, chronic disease of the kidneys, liver, and lungs), sexually transmitted diseases (e. g. HIV, chlamydia, gonorrhea), infectious diseases (e. g. tuberculosis, malaria, Helicobacter pylori), allergies (e. g. house dust, cats, histamine) and cancer as well as tests for the diagnostics of 12 different psychotropic substances. These were sold by 90 companies in Germany and by other foreign companies. The number of medical-diagnostic self-tests which can be bought without a medical prescription on the Internet has increased enormously in the last 10 years. Further studies are needed for the identification of the determinants of the use of self-tests as well as the impact of the application on the experience and behavior of the user. © Georg Thieme Verlag KG Stuttgart · New York.
Testing promotes effector transfer.
Boutin, Arnaud; Panzer, Stefan; Salesse, Robin N; Blandin, Yannick
2012-11-01
The retrieval of information from memory during testing has recently been shown to promote transfer in the verbal domain. Motor-related research, however, has ignored testing as a relevant method to enhance motor transfer. We thus investigated whether testing has the potential to induce generalised motor memories by favouring effector transfer. Participants were required to reproduce a spatial-temporal pattern of elbow extensions and flexions with their dominant right arm. We tested the ability of participants to transfer the original pattern (extrinsic transformation; i.e., goal-based configuration) or the mirrored pattern (intrinsic transformation; i.e., movement-based configuration) to the unpractised non-dominant left arm. To evaluate how testing affects motor transfer at 24-h testing, participants were either administered an initial testing session during early practice (early testing group) or shortly after the end of practice (late testing group; i.e., no alternation between practice and testing sessions). No initial testing session was completed for the control group. We found better effector transfer at 24-h testing for the early testing group for both extrinsic and intrinsic transformations of the movement pattern when compared with the control group, while no testing benefit was observed for the late testing group. This indicates that testing positively affects motor learning, yielding enhanced long-term transfer capabilities. We thus demonstrate the critical role of retrieval practice via testing during the process of motor memory encoding, and provide the conditions under which testing effectively contributes to the generalisation of motor memories. Copyright © 2012 Elsevier B.V. All rights reserved.
O'Driscoll, B R; Powell, G; Chew, F; Niven, R M; Miles, J F; Vyas, A; Denning, D W
2009-11-01
It has been shown that patients with allergic bronchopulmonary aspergillosis (ABPA) and patients with severe asthma with fungal sensitization (SAFS) can benefit from antifungal therapy. It is not known whether allergy skin prick tests (SPT) or specific IgE tests are more sensitive in the identification of patients who are sensitized to fungi and who are therefore candidates for antifungal therapy. To compare SPT and specific serum IgE tests for fungal sensitization in patients with severe asthma. We have undertaken SPT and specific serum IgE tests to six fungi (Aspergillus fumigatus, Candida albicans, Penicillium notatum, Cladosporium herbarum, Alternaria alternata and Botrytis cineria) and specific serum IgE test for Trichophyton in 121 patients with severe asthma (British Thoracic Society/SIGN steps 4 and 5). Sixty-six percent of patients were sensitized to one or more fungi based on SPT and/or specific serum IgE results. Positivity to SPT and/or specific serum IgE was as follows: A. fumigatus 45%, C. albicans 36%, P. notatum 29%, C. herbarum 24%, A. alternata 22%, B. cineria 18%, Trichophyton 17% (specific serum IgE only). Concordance between the tests was 77% overall but only 14-56% for individual fungi. Twenty-nine (24%) patients were sensitized to a single fungus and seven (6%) were sensitized to all seven fungal species. Fifty percent of patients were sensitized to fungal and non-fungal extracts, 21% were sensitized only to non-fungal extracts, 16% were sensitized only to fungal extracts and 13% had no positive tests. This study is consistent with previous reports that fungal sensitization is common in patients with severe asthma. At present, it remains necessary to undertake both SPT and specific serum IgE testing to identify all cases of fungal sensitization. This may be important in the identification of patients with ABPA and SAFS who may benefit from antifungal therapy.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Toxicity to Plants (Algae): ASTM E 1218 Test Group 2 for C1: 1. Chronic Toxicity to Daphnia: ASTM E 1193 2. Toxicity to Plants (Algae): ASTM E 1218 The following are the special conditions for C1, C2, C3, C4, C5.... Acute Toxicity to Daphnia: ASTM E 729 2. Toxicity to Plants (Algae): ASTM E 1218 Test Group 2 for C2: 1...
Seal material development test program
NASA Technical Reports Server (NTRS)
1971-01-01
A program designed to characterize an experimental fluoroelastomer material designated AF-E-124D, is examined. Tests conducted include liquid nitrogen load compression tests, flexure tests and valve seal tests, ambient and elevated temperature compression set tests, and cleaning and flushing fluid exposure tests. The results of these tests indicate the AF-E-124D is a good choice for a cryogenic seal, since it exhibits good low temperature sealing characteristics and resistance to permanent set. The status of this material as an experimental fluorelastomer is stressed and recommended. Activity includes definition and control of critical processing to ensure consistent material properties. Design, fabrication and test of this and other materials is recommended in valve and static seal applications.
Odegard, Timothy N; Koen, Joshua D
2007-11-01
Both positive and negative testing effects have been demonstrated with a variety of materials and paradigms (Roediger & Karpicke, 2006b). The present series of experiments replicate and extend the research of Roediger and Marsh (2005) with the addition of a "none-of-the-above" response option. Participants (n=32 in both experiments) read a set of passages, took an initial multiple-choice test, completed a filler task, and then completed a final cued-recall test (Experiment 1) or multiple-choice test (Experiment 2). Questions were manipulated on the initial multiple-choice test by adding a "none-of-the-above" response alternative (choice "E") that was incorrect ("E" Incorrect) or correct ("E" Correct). The results from both experiments demonstrated that the positive testing effect was negated when the "none-of-the-above" alternative was the correct response on the initial multiple-choice test, but was still present when the "none-of-the-above" alternative was an incorrect response.
Shi, Wenxin; Wang, Lizheng; Rousseau, Diederik P L; Lens, Piet N L
2010-05-01
Many pollutants have received significant attention due to their potential estrogenic effect and are classified as endocrine disrupting compounds (EDCs). Because of possible ecological effects and increased attention for water reuse schemes, it is important to increase our understanding of the EDC removal capacities of various wastewater treatment systems. However, there has so far been little research on the fate and behavior of EDCs in stabilization pond systems for wastewater treatment, which represent an important class of wastewater treatment systems in developing countries because of their cost-effectiveness. The aim of this work is to study the fate and behavior of EDCs in algae and duckweed ponds. Because the synthetic hormone 17alpha-ethinylestradiol (EE2) and the natural hormones estrone (E1), as well as 17beta-estradiol (E2), have been detected in effluents of sewage treatment plants and been suggested as the major compounds responsible for endocrine disruption in domestic sewage; E1, E2, and EE2 were therefore chosen as target chemicals in this current work. Both batch tests and continuous-flow tests were carried out to investigate the sorption and biodegradation of estrogens in algae and duckweed pond systems. The applied duckweed was a Lemna species. The applied algae was a mixture of pure cultures of six different algae genera, i.e., Anabaena cylindrica, Chlorococcus, Spirulina platensis, Chlorella, Scenedesmus quadricauda, and Anaebena var. Synthetic wastewater were used in all tests. The concentrations of estrogens were measured with three different enzyme-linked immunosorbent assay kits specific for E1, E2, or EE2. When the concentrations of estrogens in water samples were below the lowest quantitative analysis range (0.05 microg/l), preconcentration of the water samples were performed by means of solid phase extraction (SPE) with C18 cartridges. The 6-day batch tests show that the presence of algae or duckweed accelerated the removal of the three estrogens from the synthetic wastewater. More estrogens were removed in the tests with duckweed than in tests with algae or with wastewater. In the sorption tests, a swift sorption of the three estrogens was observed when the estrogens were contacted with duckweed or algae, while the estrogen concentrations in tap water kept unchanged during the 3-h sorption tests. The mass balances indicated that only about 5% of the estrogens were bound to the algae sediment or duckweed at the end of the 6-day tests. Results of the continuous-flow tests revealed that the algae and duckweed ponds effectively removed E1, E2, and EE2 even at nanograms per liter level. Interconversion of E1 and E2 occurred both in batch and continuous-flow tests. E2 could be readily transformed to E1, especially in the tests with algae. Different processes like sorption, biodegradation and photolytic degradation might play an important role in the removal of estrogens from the aquatic phase. The 3-h sorption tests support the importance of sorption for estrogen removal, in which a rapid initial sorption was observed over the first 2 min for E1/E2/EE2 to both duckweed and algae. In the 6-day batch tests, estrogens were sorbed by algae or duckweed during the early stage when algae and duckweed were contacted with the synthetic wastewater and the sorbed estrogens were further biodegraded by the microorganisms developed in the wastewater. The persistent estrogen concentrations in tap water, however, implied that no sorption, biodegradation, or photolytic degradation occurred in tap water under the specific experimental conditions. Under aerobic or anoxic conditions, E2 could be first oxidized to E1, which is further oxidized to unknown metabolites and finally to CO(2) and water. Under anaerobic conditions, E1 can also be reduced to E2. However, the interconversion might be much more complex especially in the tests with algae because both aerobic and anaerobic conditions occurred in these tests due to the variation of the dissolved oxygen concentration induced by the light regime. This study shows that estrogens, E1, E2, and EE2, can be effectively removed from the continuous-flow algae and duckweed ponds even when their concentrations are at nanograms per liter level. The presence of algae and duckweed accelerate the removal of estrogens from the synthetic wastewater because estrogens can be quickly sorbed on duckweed or algae. The sorbed estrogens are subsequently degraded by microorganisms, algae, or duckweed in the wastewater treatment system. E1 and E2 are interconvertible in both duckweed and algae pond systems. E2 can be readily transformed to E1, especially in the tests with algae. Based on the tests performed so far, one can conclude that both sorption and biodegradation are important to the estrogens removal from stabilization pond systems for wastewater treatment. Further research using, e.g., radioimmunoassay is needed to investigate the biodegradation pathway of estrogens in algae and duckweed ponds.
Hamilton, R G; Adkinson, N F
1996-11-01
Nonammoniated latex, ammoniated latex, and rubber glove extracts are the only sources of natural rubber (Hevea brasiliensis) latex that have potential for use as skin testing reagents in the diagnosis of latex allergy. Their diagnostic sensitivity and specificity as skin test reagents are unknown. We conducted a phase 1/2 clinical study to examine the safety and diagnostic accuracy (sensitivity and specificity) of nonammoniated latex, ammoniated latex, and rubber glove extracts as skin test extracts to identify the most efficacious source material for future skin test reagent development. Twenty-four adults not allergic to latex, 19 adults with hand dermatitis or pruritus, and 59 adults with a latex allergy were identified by clinical history. All provided blood and then received puncture skin tests and intradermal skin tests with nonammoniated latex, ammoniated latex, and rubber glove extracts from Malaysian H. brasiliensis latex by use of sequential titration. A glove provocation test and IgE anti-latex RAST were used to clarify positive history-negative skin test response and negative history-positive skin test response mismatches. All three extracts were biologically safe and sterile. After normalization to 1 mg/ml of total protein, all three extracts produced equivalent diagnostic sensitivity and specificity in puncture skin tests and intradermal skin tests at various extract concentrations. Optimal diagnostic accuracy was safely achieved at 100 micrograms/ml for intradermal skin tests (e.g., nonammoniated latex: puncture skin test sensitivity 96%, specificity 100%; intradermal skin test sensitivity 93%, specificity 96%). The presence of IgE antibody in skin was highly correlated with IgE anti-latex in serum (nonammoniated latex: r = 0.98, p < 0.001; ammoniated latex: r = 0.94, p < 0.001; rubber glove extract: r = 0.96, p < 0.001). All five available subjects with a positive history, negative skin test response, and absence of IgE antibody in serum had a negative glove provocation test response, indicating no clinical evidence of latex allergy. No systemic or large local allergic reactions were observed with puncture skin tests or intradermal skin tests. Equivalent diagnostic sensitivity and specificity were observed with the nonammoniated latex, ammoniated latex, and rubber glove extract skin test reagents after normalization for total protein; nonammoniated latex may be considered the reagent of choice on the basis of practical quality control and reproducibility considerations.
Shariati, Laleh; Validi, Majid; Tabatabaiefar, Mohammad Amin; Karimi, Ali; Nafisi, Mohammad Reza
2010-12-01
Methicillin-resistant Staphylococcus aureus (MRSA) is a nosocomial pathogen. Our main objective was to compare oxacillin disk test, oxacillin E-test, and oxacillin agar screen for detection of methicillin resistance in S. aureus, using real-time PCR for mecA as the "gold standard" comparison assay. 196 S. aureus isolates were identified out of 284 Staphylococcus isolates. These isolates were screened for MRSA with several methods: disk diffusion, agar screen (6.0 μg/ml), oxacillin E-test, and real-time PCR for detection of mecA gene. Of the 196 S. aureus isolates tested, 96 isolates (49%) were mecA-positive and 100 isolates (51%) mecA-negative. All methods tested had a statistically significant agreement with real-time PCR. E-test was 100% sensitive and specific for mecA presence. The sensitivity and specificity of oxacillin agar screen method were 98 and 99%, respectively and sensitivity and specificity of oxacillin disk diffusion method were 95 and 93%, respectively. In the present study, oxacillin E-test is proposed as the best phenotypic method. For economic reasons, the oxacillin agar screen method (6.0 μg/ml), which is suitable for the detection of MRSA, is recommended due to its accuracy and low cost.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corradini, N; Leick, M; Bonetti, M
Purpose: To determine the MVCT imaging uncertainty on the TomoHDA system for intracranial radiosurgery treatments. To determine the end-to-end (E2E) overall accuracy of the TomoHDA system for intracranial radiosurgery. Methods: A pig head was obtained from the butcher, cut coronally through the brain, and preserved in formaldehyde. The base of the head was fixed to a positioning plate allowing precise movement, i.e. translation and rotation, in all 6 axes. A repeatability test was performed on the pig head to determine uncertainty in the image bone registration algorithm. Furthermore, the test studied images with MVCT slice thicknesses of 1 and 3more » mm in unison with differing scan lengths. A sensitivity test was performed to determine the registration algorithm’s ability to find the absolute position of known translations/rotations of the pig head. The algorithm’s ability to determine absolute position was compared against that of manual operators, i.e. a radiation therapist and radiation oncologist. Finally, E2E tests for intracranial radiosurgery were performed by measuring the delivered dose distributions within the pig head using Gafchromic films. Results: The repeatability test uncertainty was lowest for the MVCTs of 1-mm slice thickness, which measured less than 0.10 mm and 0.12 deg for all axes. For the sensitivity tests, the bone registration algorithm performed better than human eyes and a maximum difference of 0.3 mm and 0.4 deg was observed for the axes. E2E test results in absolute position difference measured 0.03 ± 0.21 mm in x-axis and 0.28 ± 0.18 mm in y-axis. A maximum difference of 0.32 and 0.66 mm was observed in x and y, respectively. The average peak dose difference between measured and calculated dose was 2.7 cGy or 0.4%. Conclusion: Our tests using a pig head phantom estimate the TomoHDA system to have a submillimeter overall accuracy for intracranial radiosurgery.« less
2017-11-01
The Under-body Blast Methodology (UBM) for the Test and Evaluation (T&E) program was established to provide a capability for the US Army Test and... Evaluation Command to assess the vulnerability of vehicles to under-body blast. Finite element (FE) models are part of the current UBM for T&E methodology...Methodology (UBM) for the Test and Evaluation (T&E) program was established to provide a capability for the US Army Test and Evaluation Command
Blood tests for allergy in children. Allergy Section, Canadian Paediatric Society.
1990-01-01
Skin tests and RASTs are important tools but do not by themselves make or exclude the diagnosis of allergy. Positive results require a confirmatory medical history, whereas negative results exclude IgE-mediated allergy with a high degree of reliability. Skins tests are preferred for routine use, because with appropriate procedural controls they are simpler, give rapid results and are cost-effective. RASTs are an excellent alternative when skin tests are precluded. Disorders such as asthma and allergic rhinitis may be provoked by irritants (e.g., cigarette smoke), physical factors (e.g., cold, dry air) and chemical substances (e.g., acetylsalicylic acid) and metabisulfite), none of which involve an IgE-antibody-mediated mechanism. PMID:2344576
40 CFR 86.230-94 - Test sequence: general requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... testing. (2) The ambient temperature reported shall be a simple average of the test cell temperatures... cell temperature shall be 20 °F±3 °F (−7 °C±1.7 °C) when measured in accordance with paragraph (e)(2... approximately level during all phases of the test sequence to prevent abnormal fuel distribution. (e) Engine...
40 CFR 63.5993 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2010 CFR
2010-07-01
... CATEGORIES National Emissions Standards for Hazardous Air Pollutants: Rubber Tire Manufacturing General... specified in § 63.7(e)(1). (d) You must conduct three separate test runs for each performance test required... test run must last at least 1 hour. (e) If you are complying with the emission limitations using a...
Test and evaluation procedures for Sandia's Teraflops Operating System (TOS) on Janus.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnette, Daniel Wayne
This report describes the test and evaluation methods by which the Teraflops Operating System, or TOS, that resides on Sandia's massively-parallel computer Janus is verified for production release. Also discussed are methods used to build TOS before testing and evaluating, miscellaneous utility scripts, a sample test plan, and a proposed post-test method for quickly examining the large number of test results. The purpose of the report is threefold: (1) to provide a guide to T&E procedures, (2) to aid and guide others who will run T&E procedures on the new ASCI Red Storm machine, and (3) to document some ofmore » the history of evaluation and testing of TOS. This report is not intended to serve as an exhaustive manual for testers to conduct T&E procedures.« less
Status of the eROSITA Telescope testing and calibrating the x-ray mirror assemblies
NASA Astrophysics Data System (ADS)
Burwitz, Vadim; Predehl, Peter; Bräuninger, Heinrich; Burkert, Wolfgang; Dennerl, Konrad; Eder, Josef; Friedrich, Peter; Fürmetz, Maria; Grisoni, Gabriele; Hartner, Gisela; Marioni, Fabio; Menz, Benedikt; Pfeffermann, Elmar; Valsecchi, Giuseppe
2013-09-01
The eROSITA X-ray observatory that will be launched on board the Russian Spectrum-RG mission comprises seven X-ray telescopes, each with its own mirror assembly (mirror module + X-ray baffle), electron deflector, filter wheel, and CCD camera with its control electronics. The completed flight mirror modules are undergoing many thorough X-ray tests at the PANTHER X-ray test facility after delivery, after being mated with the X-ray baffle, and again after both the vibration and thermal-vacuum tests. A description of the work done with mirror modules/assemblies and the test results obtained will be reported here. We report also on the environmental tests that have been performed on the eROSITA telescope qualification model.
Process qualification and testing of LENS deposited AY1E0125 D-bottle brackets.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atwood, Clinton J.; Smugeresky, John E.; Jew, Michael
2006-11-01
The LENS Qualification team had the goal of performing a process qualification for the Laser Engineered Net Shaping{trademark}(LENS{reg_sign}) process. Process Qualification requires that a part be selected for process demonstration. The AY1E0125 D-Bottle Bracket from the W80-3 was selected for this work. The repeatability of the LENS process was baselined to determine process parameters. Six D-Bottle brackets were deposited using LENS, machined to final dimensions, and tested in comparison to conventionally processed brackets. The tests, taken from ES1E0003, included a mass analysis and structural dynamic testing including free-free and assembly-level modal tests, and Haversine shock tests. The LENS brackets performedmore » with very similar characteristics to the conventionally processed brackets. Based on the results of the testing, it was concluded that the performance of the brackets made them eligible for parallel path testing in subsystem level tests. The testing results and process rigor qualified the LENS process as detailed in EER200638525A.« less
[Clinical symptoms and immunology inspection characteristics of nasal cavity local allergy].
Yin, Z X; Zhu, Y; Zhai, X; Zhang, J L; Liu, G
2017-08-05
Objective: To investigate the clinical symptoms and immunology inspection characteristics of nasal cavity local allergy. Method: Selected 60 patients as observation group, who had only nasal local allergy symptoms, allergen skin prick test and serum allergen specific IgE (SIgE) test were negative, 40 allergic rhinitis (AR) patients and 40 healthy volunteers as control groups. To detect Symptom scores and VAS scores, and eosinophilia counts in venous blood, allergen skin prick test (SPT), serum allergen SIgE test, nasal secretions allergen SIgE test, nasal mucous membrane excitation test in both observation group and AR group, eosinophilia counts in nasal secretion, taked the data for statistical analysis. Result: There was no difference ( P > 0.05) in the symptom scores and VAS scores of observation group and the AR group. The eosinophilia counts in venous blood in the AR group were higher than in the observation group ( P < 0.05). The eosinophilia counts in venous blood in the observation group were higher than in the healthy volunteers group ( P < 0.05). The positive rate of nasal secretions dust mites and pollen allergen was 90% (54/60) in observation group. There was no significant difference ( P > 0.05) in the eosinophilia percentages in nasal secretion in the observation group and the AR group. There was significant difference ( P < 0.05) in the eosinophilia percentages in nasal secretion in the observation group and the healthy volunteers group. There were 6 patients in observation group whose nasal secretions allergen SIgE test and nasal mucous membrane excitation test were both negative, could be diagnosised as non-allergic rhinitis (NAR). According to eosinophilia counts in venous blood and nasal secretions, 4 patients were diagnosised as vasomotor rhinitis and 2 patients were diagnosised as NAR with eosinophilia syndrome. There were 54 patients in observation group whose nasal secretions allergen SIgE test and (or) nasal mucous membrane excitation test were positive, could be diagnosised as local allergic rhinitis. After three years, all of the observation group patients were detected with SPT and serum allergen SIgE test. Five patients diagnosed as local allergic rhinitis before three years were positive. Six patients diagnosed as NAR before three years were negative. Conclusion: For patients with the typical medical history and symptoms of AR, but allergen SPT and serum allergen SIgE test were negative, there was local specific hypersensitivity in nasal mucosa, but the reaction was not accompanied by systemic sensitization. Combined with nasal secretions allergen SIgE test or allergen nasal mucosa proocation tests positive, could be diagnosed as local allergic rhinitis. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.
Ren, H L; Li, J D; Miao, Y H; Xu, T
2018-03-01
Objective: To investigate the clinical application of glass micro fiber basophil activation test (BAT) used as a complementary test for house dust mite allergen. Method: Forty patients with clinical diagnosed allergic rhinitis was test by three methods for house dust mite allergen, skin prick test(SPT),Immuno CAP sIgE, and BAT in vitro. The sensitivity and specificity of glass micro fiber were accessed, and the consistency between BAT, SPT, and Immuno sIgE was analyzed. As in vivo provocation was not performed, gold standard is regarded as the combination of medical history and positive reports of SPT and/or ImmunoCAP sIgE test. Result: Twentythree patients are diagnosed as house dust mite allergic rhinitis by gold standard. The sensitivity and specificity of glass micro fiber BAT were 60.9% and 88.2%, the sensitivity of SPT and sIgE was 87.0% and sIgE 73.9%. The correlation rates between BAT with SPT is 0.67( P <0.05), and sIgE 0.55( P <0.05). The accuracy, predictive value of positive and negative of BAT are 0.47,60.9%,88.2%.The Kappa values of BAT, SPT and sIgE with gold standard are 0.47,0.86,0.71. Conclusion: As a complementary test for house dust mite allergic rhinitis, BAT have a good consistency with SPT and sIgE, while as it has only moderate consistency with "gold standard", further studies are needed to prove its clinical significance. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.
van Kampen, V; Rabstein, S; Sander, I; Merget, R; Brüning, T; Broding, H C; Keller, C; Müsken, H; Overlack, A; Schultze-Werninghaus, G; Walusiak, J; Raulf-Heimsoth, M
2008-07-01
Wheat and rye flours are among the most important allergens causing occupational asthma. Usually, the diagnosis of baker's asthma is based on inhalation challenge tests with flours. To evaluate the relevance of flour-specific serum immunoglobulin E (IgE) and skin prick test (SPT) in the diagnosis of baker's asthma and to define flour-specific IgE concentrations and wheal sizes that allow a prediction of the outcome of challenge testing. Bronchial and nasal challenge tests with wheat (rye) flour were performed in 71 (95) symptomatic bakers. Determinations of flour-specific IgE as well as SPTs were performed in all subjects. Analyses included the calculation of sensitivity, specificity, positive (PPV) and negative predictive values (NPV) at different IgE concentrations and different wheal sizes, and receiver-operating characteristics (ROC) plots with the challenge result as gold standard. Thirty-seven bakers were positive in the challenge with wheat flour, while 63 were positive with rye flour. Depending on the flour-specific IgE concentrations (wheal size), PPV was 74-100% (74-100%) for wheat and 82-100% (91-100%) for rye flour, respectively. The minimal cut-off values with a PPV of 100% were 2.32 kU/l (5.0 mm) for wheat flour and 9.64 kU/l (4.5 mm) for rye flour. The shapes of the ROC plots were similar for wheat and rye flour. High concentrations of flour-specific IgE and clear SPT results in symptomatic bakers are good predictors for a positive challenge test. Challenge tests with flours may be avoided in strongly sensitized bakers.
DipTest: A litmus test for E. coli detection in water.
Gunda, Naga Siva Kumar; Dasgupta, Saumyadeb; Mitra, Sushanta K
2017-01-01
We have developed a new litmus paper test (DipTest) for detecting Escherichia coli (E. coli) in water samples by performing enzymatic reactions directly on the porous paper substrate. The paper strip consists of a long narrow piece of cellulose blotting paper coated with chemoattractant (at bottom edge), wax hydrophobic barrier (at the top edge), and custom formulated chemical reagents (at reaction zone immediately below the wax hydrophobic barrier). When the paper strip is dipped in water, E. coli in the water sample is attracted toward the paper strip due to a chemotaxic mechanism followed by the ascent along the paper strip toward the reaction zone due to a capillary wicking mechanism, and finally the capillary motion is arrested at the top edge of the paper strip by the hydrophobic barrier. The E. coli concentrated at the reaction zone of the paper strip will react with custom formulated chemical reagents to produce a pinkish-red color. Such a color change on the paper strip when dipped into water samples indicates the presence of E. coli contamination in potable water. The performance of the DipTest device has been checked with different known concentrations of E. coli contaminated water samples using different dip and wait times. The DipTest device has also been tested with different interfering bacteria and chemical contaminants. It has been observed that the different interfering contaminants do not have any impact on the DipTest, and it can become a potential solution for screening water samples for E. coli contamination at the point of source.
DipTest: A litmus test for E. coli detection in water
Gunda, Naga Siva Kumar; Dasgupta, Saumyadeb
2017-01-01
We have developed a new litmus paper test (DipTest) for detecting Escherichia coli (E. coli) in water samples by performing enzymatic reactions directly on the porous paper substrate. The paper strip consists of a long narrow piece of cellulose blotting paper coated with chemoattractant (at bottom edge), wax hydrophobic barrier (at the top edge), and custom formulated chemical reagents (at reaction zone immediately below the wax hydrophobic barrier). When the paper strip is dipped in water, E. coli in the water sample is attracted toward the paper strip due to a chemotaxic mechanism followed by the ascent along the paper strip toward the reaction zone due to a capillary wicking mechanism, and finally the capillary motion is arrested at the top edge of the paper strip by the hydrophobic barrier. The E. coli concentrated at the reaction zone of the paper strip will react with custom formulated chemical reagents to produce a pinkish-red color. Such a color change on the paper strip when dipped into water samples indicates the presence of E. coli contamination in potable water. The performance of the DipTest device has been checked with different known concentrations of E. coli contaminated water samples using different dip and wait times. The DipTest device has also been tested with different interfering bacteria and chemical contaminants. It has been observed that the different interfering contaminants do not have any impact on the DipTest, and it can become a potential solution for screening water samples for E. coli contamination at the point of source. PMID:28877199
Repair bond strength of resin composite to bilayer dental ceramics
2018-01-01
PURPOSE The purpose of this study was to investigate the effect of various surface treatments (ST) on the shear bond strength of resin composite to three bilayer dental ceramics made by CAD/CAM and two veneering ceramics. MATERIALS AND METHODS Three different bilayer dental ceramics and two different veneering ceramics were used (Group A: IPS e.max CAD+IPS e.max Ceram; Group B: IPS e.max ZirCAD+IPS e.max Ceram, Group C: Vita Suprinity+Vita VM11; Group D: IPS e.max Ceram; Group E: Vita VM11). All groups were divided into eight subgroups according to the ST. Then, all test specimens were repaired with a nano hybrid resin composite. Half of the test specimens were subjected to thermocycling procedure and the other half was stored in distilled water at 37℃. Shear bond strength tests for all test specimens were carried out with a universal testing machine. RESULTS There were statistically significant differences among the tested surface treatments within the all tested fracture types (P<.005). HF etching showed higher bond strength values in Groups A, C, D, and E than the other tested ST. However, bonding durability of all the surface-treated groups were similar after thermocycling (P>.00125). CONCLUSION This study revealed that HF etching for glass ceramics and sandblasting for zirconia ceramics were adequate for repair of all ceramic restorations. The effect of ceramic type exposed on the fracture area was not significant on the repair bond strength of resin composites to different ceramic types. PMID:29713430
Dupont, S; De Spiegeleer, A; Liu, D J X; Lefère, L; van Doorn, D A; Hesta, M
2016-01-01
Commercial immunoglobulin E (IgE)-based tests are available for diagnosis of food allergies and are commonly used in equine practice. However, these tests have been proven unreliable as a screening method in man and other species, but not critically evaluated in equids. Therefore, a commercially available IgE-based test for horses was evaluated. To evaluate the consistency of the results obtained with a commercially available IgE-based test for food allergy diagnosis in ponies (Phase I) and to subject ponies to a provocation trial with the presumed allergens (Phase II). Allergen screening followed by experimental food provocation trials in healthy ponies. Blood samples of 17 healthy Shetland ponies were taken at 2 different time points, sent blinded to a commercial laboratory for screening of common food allergens and the results were evaluated for consistency (Phase I). Ponies that were positive for food allergens were consecutively challenged orally with each allergen separately for 14 days (Phase II). A washout period of one week was applied in ponies with multiple positive results. Clinical parameters and serum amyloid A were monitored during the provocation trial. Only 7/17 ponies were negative on the IgE-based test at the 2 time points, 3 had positive results twice but only one tested positive twice for the same food allergen. No abnormalities were noted during the provocation trials. This study demonstrated that this IgE-based test is not a reliable screening tool for food allergy in healthy equids. © 2015 EVJ Ltd.
5. Credit BG. View looking northwest at eastern facade of ...
5. Credit BG. View looking northwest at eastern facade of Test Stand 'E' (Building 4259/E-60), solid rocket motor test facility. Central bay (high concrete walls) was used for testing large solid motors in a vertical position. A second smaller bay to the north fired smaller motors horizontally. Just south of the large bay is an equipment room with access to the tunnel system; entrance is by small single door on east side. The large double doors lead to a third bay used for X-raying solid rocket motors before testing. - Jet Propulsion Laboratory Edwards Facility, Test Stand E, Edwards Air Force Base, Boron, Kern County, CA
NASA Astrophysics Data System (ADS)
Strohmeier, Dominik; Kunze, Kristina; Göbel, Klemens; Liebetrau, Judith
2013-01-01
Assessing audiovisual Quality of Experience (QoE) is a key element to ensure quality acceptance of today's multimedia products. The use of descriptive evaluation methods allows evaluating QoE preferences and the underlying QoE features jointly. From our previous evaluations on QoE for mobile 3D video we found that mainly one dimension, video quality, dominates the descriptive models. Large variations of the visual video quality in the tests may be the reason for these findings. A new study was conducted to investigate whether test sets of low QoE are described differently than those of high audiovisual QoE. Reanalysis of previous data sets seems to confirm this hypothesis. Our new study consists of a pre-test and a main test, using the Descriptive Sorted Napping method. Data sets of good-only and bad-only video quality were evaluated separately. The results show that the perception of bad QoE is mainly determined one-dimensionally by visual artifacts, whereas the perception of good quality shows multiple dimensions. Here, mainly semantic-related features of the content and affective descriptors are used by the naïve test participants. The results show that, with increasing QoE of audiovisual systems, content semantics and users' a_ective involvement will become important for assessing QoE differences.
Video- or text-based e-learning when teaching clinical procedures? A randomized controlled trial.
Buch, Steen Vigh; Treschow, Frederik Philip; Svendsen, Jesper Brink; Worm, Bjarne Skjødt
2014-01-01
This study investigated the effectiveness of two different levels of e-learning when teaching clinical skills to medical students. Sixty medical students were included and randomized into two comparable groups. The groups were given either a video- or text/picture-based e-learning module and subsequently underwent both theoretical and practical examination. A follow-up test was performed 1 month later. The students in the video group performed better than the illustrated text-based group in the practical examination, both in the primary test (P<0.001) and in the follow-up test (P<0.01). Regarding theoretical knowledge, no differences were found between the groups on the primary test, though the video group performed better on the follow-up test (P=0.04). Video-based e-learning is superior to illustrated text-based e-learning when teaching certain practical clinical skills.
Video- or text-based e-learning when teaching clinical procedures? A randomized controlled trial
Buch, Steen Vigh; Treschow, Frederik Philip; Svendsen, Jesper Brink; Worm, Bjarne Skjødt
2014-01-01
Background and aims This study investigated the effectiveness of two different levels of e-learning when teaching clinical skills to medical students. Materials and methods Sixty medical students were included and randomized into two comparable groups. The groups were given either a video- or text/picture-based e-learning module and subsequently underwent both theoretical and practical examination. A follow-up test was performed 1 month later. Results The students in the video group performed better than the illustrated text-based group in the practical examination, both in the primary test (P<0.001) and in the follow-up test (P<0.01). Regarding theoretical knowledge, no differences were found between the groups on the primary test, though the video group performed better on the follow-up test (P=0.04). Conclusion Video-based e-learning is superior to illustrated text-based e-learning when teaching certain practical clinical skills. PMID:25152638
Kumar, Raj; Gupta, Nitesh; Kanuga, Jayesh; Kanuga, Mansi
2015-01-01
Skin prick testing (SPT) is the 'gold standard' in the assessment of allergic sensitivity to inhalant allergens. Serum-specific immunoglobulin E (SSIgE) measurement is a complementary test. SPT is performed with antigen extracts from India while SSIgE utilises extracts derived from European antigens. To evaluate the performance of allergic assessment by SSIgE against cockroach, housefly and mosquito aeroallergens which are frequently implicated in driving respiratory allergies in India considering SPT as the 'gold standard'. Twenty patients (mean age 28.5 years; range 15-50 years) diagnosed to have bronchial asthma and/or rhinitis underwent SPT. The SSIgE levels were obtained at the same visit. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SSIgE testing were calculated using SPT as the 'gold standard'. The correlation between SPT grading and SSIgE levels was also evaluated. The sensitivity of SSIgE testing to each of the 3 aero-allergens was > 85%. The PPV of cockroach and mosquito SSIgE was > 85%; housefly SSIgE had PPV of 68.7%. The two tests were in agreement in 85% (cockroach), 90% (mosquito) and 55% (housefly). There was a significant correlation between the grades of SPT reactions and SSIgE levels. The SSIgE has higher sensitivity and PPV, but lacks specificity. Higher sensitivity with low specificity leads to increased false positive diagnosis of allergic disease. Unlike allergenic pollens, however, insect antigen extracts from different regions seem to give comparable results, and can thus, reliably be used in the evaluation of allergy.
Becker, Otávio Monteiro; Azevedo, João Luiz Moreira Coutinho; de Azevedo, Otávio Cansanção; Hypólito, Octávio Henrique Mendes; Miyahira, Susana Abe; Miguel, Gustavo Peixoto Soares; Machado, Afonso Cesar Cabral Guedes
2011-01-01
To assess the effectiveness of the Veress needle puncture in the left hypochondrium and the accuracy of the tests described for the intraperitoneal correct positioning of the tip of the Veress needle in an unselected population. Ninetyone patients consecutively scheduled for Videolaparoscopy had the abdominal wall punctured in the left hypochondrium. There were no exclusion criteria. The patients received general anesthesia and mechanical ventilation according to the protocol. After puncturing five tests were used to confirm the positioning of the needle tip within the peritoneal cavity: aspiration test--AT; resistance to infusion--Pres; recovery of the infused fluid--Prec, dripping test--DT, and test of initial intraperitoneal pressure--IIPP. The test results were compared with results from literature for groups with defined exclusion criteria. The results were used for calculating sensitivity (S) specificity (E), positive predictive value (PPV) and negative predictive value (NPV). Inferential statistical methods were used to analyze the findings. There were 13 failures. AT had E = 100% and NPV 100%. Pres had S = 100%, E = 0; PPV = 85.71%; NPV does not apply. Prec: S = 100%, E = 53.84%, PPV = 92.85%, NPV = 100%. DT: S = 100%, E = 61.53%, PPV = 93.97% NPV 100%. In IIPP, S, E, PPV and NPV were 100%. The puncture in the left hypochondrium is effective and the performed tests guide the surgeon regardless of sex, BMI, or previous laparotomy.
Shayakhmetova, Ganna M; Bondarenko, Larysa B; Matvienko, Anatoliy V; Kovalenko, Valentina M
2014-09-01
The aim of the study was to investigate the correlation between spermatogenesis disorders and CYP2E1 mRNA contents in testes of rats with experimental alcoholism or type I diabetes. Two pathological states characterized by CYP2E1 induction were simulated on Wistar male rats: experimental alcoholism and type I diabetes. As controls for each state, equal number of animals (of the same age and weight) were used. Morphological evaluation of rat testes was carried out. The spermatogenic epithelium state was estimated by four points system. CYP2E1 mRNA expression was rated by method of reverse transcriptase polymerase chain reaction. Pearson correlation coefficients were used for describing relationships between variables. The presence of alcoholism and diabetes-mediated quantitative and qualitative changes in male rat spermatogenic epithelium in comparison with norm has been demonstrated. The increased levels of testes CYP2E1 have been fixed simultaneously. CYP2E1 mRNA content negatively strongly correlated with spermatogenic index value (r=-0.99; P<0.001) and positively strongly correlated with epithelium desquamation occurrence (r=0.99; P<0.001) in testes of rats with chronic alcoholism. The strong correlation between CYP2E1 mRNA content and number of spermatogonia (r=0.99; P<0.001) and "windows" occurrence (r=0.96; P<0.001) has been fixed in diabetic rats testes. Present investigation has demonstrated that the testicular failure following chronic ethanol consumption and diabetes type I in male rats accompanied CYP2E1 mRNA over-expression in testes. The correlation between the levels of CYP2E1 mRNA in testes and spermatogenesis disorders allow supposing the involvement of CYP2E1 into the non-specific pathogenetic mechanisms of male infertility under above-mentioned pathologies. Copyright © 2014 Medical University of Bialystok. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
Controlled Retrieval of Specific Context Information in Children and Adults.
Lorsbach, Thomas C; Friehe, Mary J; Teten, Amy Fair; Reimer, Jason F; Armendarez, Joseph J
2015-01-01
This study adapted a procedure used by Luo and Craik (2009) to examine whether developmental differences exist in the ability to use controlled retrieval processes to access the contextual details of memory representations. Participants from 3 age groups (mean ages 9, 12, and 25 years) were presented with words in 3 study contexts: with a black-and-white picture, with a color picture, or alone without a picture. Six recognition tests were then presented that varied in the demands (high or low) placed on the retrieval of specific contextual information. Each test consisted of a mixture of words that were old targets from 1 study context, distractors (i.e., previously studied words from a different context), and completely new words. A high-specificity and a low-specificity test list was paired with each test question, with high and low specificity being determined by the nature of the distractors used in a test list. High-specificity tests contained words that were studied in similar contexts: old targets (e.g., words studied with black-and-white pictures) and distractors (e.g., words studied with color pictures). In contrast, low-specificity tests contained words that were studied in dissimilar contexts: old targets (e.g., words studied with black-and-white pictures) and distractors (e.g., words previously studied without a picture). Relative to low-specificity tests, the retrieval conditions of high-specificity tests were assumed to place greater demands on the controlled access of specific contextual information. Analysis of recollection scores revealed that age differences were present on high-but not low-specificity tests, with the performance of 9-year-olds disproportionately affected by the retrieval demands of high-specificity tests.
The Controlled Retrieval of Specific Context Information in Children and Adults
Lorsbach, Thomas C.; Reimer, Jason F.; Friehe, Mary J.; Armendarez, Joseph J.; Teten, Amy Fair
2017-01-01
The present study adapted a procedure used recently by Luo and Craik (2009) in order to examine whether developmental differences exist in the ability to use controlled retrieval processes to access the specific contextual details of memory representations. Participants from three age groups (Mean ages: 9, 12, and 25 years) were presented with words in three study contexts: with a black-and-white picture, with a color picture, or alone without a picture. Six recognition tests were then presented that varied in the demands (high or low) placed on the retrieval of specific contextual information. Each test consisted of a mixture of words that were old targets from one study context, distractors (i.e., previously studied words from a different context), and completely new words. A “high specificity” and a “low specificity” test list was paired with each test question, with “high” and “low” specificity being determined by the nature of the distractors used in a test list. High specificity tests contained words that were studied in similar contexts: old targets (e.g., words studied with black-and-white pictures) and distractors (e.g., words studied with color pictures). In contrast, low specificity tests contained words that were studied in dissimilar contexts: old targets (e.g., words studied with black-and-white pictures) and distractors (e.g., words previously studied without a picture). Relative to low specificity tests, the retrieval conditions of high specificity tests were assumed to place greater demands on the controlled access of specific contextual information. Analysis of recollection scores revealed that age differences were present on high, but not low specificity tests, with the performance of 9-year olds being disproportionately affected by the retrieval demands of high specificity tests. PMID:26219173
Branda, John A; Aguero-Rosenfeld, Maria E; Ferraro, Mary Jane; Johnson, Barbara J B; Wormser, Gary P; Steere, Allen C
2010-01-01
Standard 2-tiered immunoglobulin G (IgG) testing has performed well in late Lyme disease (LD), but IgM testing early in the illness has been problematic. IgG VlsE antibody testing, by itself, improves early sensitivity, but may lower specificity. We studied whether elements of the 2 approaches could be combined to produce a second-tier IgG blot that performs well throughout the infection. Separate serum sets from LD patients and control subjects were tested independently at 2 medical centers using whole-cell enzyme immunoassays and IgM and IgG immunoblots, with recombinant VlsE added to the IgG blots. The results from both centers were combined, and a new second-tier IgG algorithm was developed. With standard 2-tiered IgM and IgG testing, 31% of patients with active erythema migrans (stage 1), 63% of those with acute neuroborreliosis or carditis (stage 2), and 100% of those with arthritis or late neurologic involvement (stage 3) had positive results. Using new IgG criteria, in which only the VlsE band was scored as a second-tier test among patients with early LD (stage 1 or 2) and 5 of 11 IgG bands were required in those with stage 3 LD, 34% of patients with stage 1, 96% of those with stage 2, and 100% of those with stage 3 infection had positive responses. Both new and standard testing achieved 100% specificity. Compared with standard IgM and IgG testing, the new IgG algorithm (with VlsE band) eliminates the need for IgM testing; it provides comparable or better sensitivity, and it maintains high specificity.
Sharma, Hemant P; Wood, Robert A; Bravo, Andrea R; Matsui, Elizabeth C
2008-04-01
Mouse sensitization is assessed by using skin testing and serum levels of mouse allergen-specific IgE (m-IgE). However, it is unknown whether a positive skin test response or m-IgE result accurately identifies those with clinically relevant mouse sensitization. We sought to compare skin testing and m-IgE measurement in the diagnosis of mouse allergy. Sixty-nine mouse laboratory workers underwent skin prick tests (SPTs), intradermal tests (IDTs), and serum IgE measurements to mouse allergen, followed by nasal challenge to increasing concentrations of mouse allergen. Challenge response was assessed by nasal symptom score. Thirty-eight women and 31 men with a mean age of 30 years were studied. Forty-nine workers reported mouse-related symptoms, of whom 10 had positive m-IgE results and 12 had positive SPT responses. Fifteen had negative SPT responses but positive IDT responses. Positive nasal challenges were observed in 70% of workers with positive m-IgE results, 83% of workers with positive SPT responses, 33% of workers with negative SPT responses/positive IDT responses, and 0% of workers with negative IDT responses. SPTs performed best, having the highest positive and negative predictive values. Among participants with a positive challenge result, those with a positive SPT response or m-IgE result had a significantly lower challenge threshold than those with a positive IDT response (P = .01). Workers with a positive challenge result were more likely to have an increase in nasal eosinophilia after the challenge compared with those with a negative challenge result (P = .03). SPTs perform best in discriminating patients with and without mouse allergy. Mouse-specific IgE and IDTs appear to be less useful than SPTs in the diagnosis of mouse allergy.
Mueller, Ralf S; Olivry, Thierry
2017-08-30
The gold standard to diagnose adverse food reactions (AFRs) in the dog and cat is currently an elimination diet with subsequent provocation trials. However, those trials are inconvenient and client compliance can be low. Our objective was to systematically review the literature to evaluate in vivo and in vitro tests used to diagnose AFR in small animals. We searched three databases (CAB Abstracts, MEDLINE and Web of Science) for pertinent references on September 16, 2016. Among 71, 544 and 41 articles found in the CAB Abstract, MEDLINE and Web of Science databases, respectively, we selected 22 articles and abstracts from conference proceedings that reported data usable for evaluation of tests for AFR. Serum tests for food-specific IgE and IgG, intradermal testing with food antigens, lymphocyte proliferation tests, fecal food-specific IgE, patch, gastroscopic, and colonoscopic testing were evaluated. Testing for serum food-specific IgE and IgG showed low repeatability and, in dogs, a highly variable accuracy. In cats, the accuracy of testing for food-specific IgE was low. Lymphocyte proliferation tests were more frequently positive and more accurate in animals with AFR, but, as they are more difficult to perform, they remain currently a research tool. All other reported tests were only evaluated by individual studies with small numbers of animals. Negative patch test reactions have a very high negative predictability in dogs and could enable a choice of ingredients for the elimination diet in selected patients. Gastroscopic and colonoscopic testing as well as food-specific fecal IgE or food-specific serum IgG measurements appear less useful. Currently, the best diagnostic procedure to identify AFRs in small animals remains an elimination diet with subsequent provocation trials.
Oron, Anna; Szymaszek, Aneta; Szelag, Elzbieta
2015-01-01
Temporal information processing (TIP) underlies many aspects of cognitive functions like language, motor control, learning, memory, attention, etc. Millisecond timing may be assessed by sequencing abilities, e.g. the perception of event order. It may be measured with auditory temporal-order-threshold (TOT), i.e. a minimum time gap separating two successive stimuli necessary for a subject to report their temporal order correctly, thus the relation 'before-after'. Neuropsychological evidence has indicated elevated TOT values (corresponding to deteriorated time perception) in different clinical groups, such as aphasic patients, dyslexic subjects or children with specific language impairment. To test relationships between elevated TOT and declined cognitive functions in brain-injured patients suffering from post-stroke aphasia. We tested 30 aphasic patients (13 male, 17 female), aged between 50 and 81 years. TIP comprised assessment of TOT. Auditory comprehension was assessed with the selected language tests, i.e. Token Test, Phoneme Discrimination Test (PDT) and Voice-Onset-Time Test (VOT), while two aspects of attentional resources (i.e. alertness and vigilance) were measured using the Test of Attentional Performance (TAP) battery. Significant correlations were indicated between elevated values of TOT and deteriorated performance on all applied language tests. Moreover, significant correlations were evidenced between elevated TOT and alertness. Finally, positive correlations were found between particular language tests, i.e. (1) Token Test and PDT; (2) Token Test and VOT Test; and (3) PDT and VOT Test, as well as between PDT and both attentional tasks. These results provide further clinical evidence supporting the thesis that TIP constitutes the core process incorporated in both language and attentional resources. The novel value of the present study is the indication for the first time in Slavic language users a clear coexistence of the 'timing-auditory comprehension-attention' relationships. © 2015 Royal College of Speech and Language Therapists.
Quantifiable Lateral Flow Assay Test Strips
NASA Technical Reports Server (NTRS)
2003-01-01
As easy to read as a home pregnancy test, three Quantifiable Lateral Flow Assay (QLFA) strips used to test water for E. coli show different results. The brightly glowing control line on the far right of each strip indicates that all three tests ran successfully. But the glowing test line on the middle left and bottom strips reveal their samples were contaminated with E. coli bacteria at two different concentrations. The color intensity correlates with concentration of contamination.
Subscale Diffuser Testing, E-3 produces first steam
2007-10-25
Phase 2 of the A-3 Test Facility Subscale Diffuser Risk Mitigation Project at Stennis Space Center reached a milestone Oct. 25 when the E-3 Test Facility produced superheated (500+ degrees) steam for approximately 3 seconds at more than 400 psi. The test team, led by Barry Robinson of NASA's Test Projects Office, followed that success with further tests to lengthen the duration of steam production. On Nov. 1, they were able to maintain a consistent pressure and temperature of steam for 60 seconds. In December, the team began Phase 3 of the testing, providing data for the design and procurement to build the full-scale version of the steam diffuser for SSC's A-3 Test Stand.
Subscale Diffuser Testing, E-3 produces first steam
NASA Technical Reports Server (NTRS)
2007-01-01
Phase 2 of the A-3 Test Facility Subscale Diffuser Risk Mitigation Project at Stennis Space Center reached a milestone Oct. 25 when the E-3 Test Facility produced superheated (500+ degrees) steam for approximately 3 seconds at more than 400 psi. The test team, led by Barry Robinson of NASA's Test Projects Office, followed that success with further tests to lengthen the duration of steam production. On Nov. 1, they were able to maintain a consistent pressure and temperature of steam for 60 seconds. In December, the team began Phase 3 of the testing, providing data for the design and procurement to build the full-scale version of the steam diffuser for SSC's A-3 Test Stand.
ERIC Educational Resources Information Center
Karbalaei, Alireza; Rahmanzade, Mehrnaz Kashkooli
2015-01-01
The present study focused on the analysis of listening sections of two international English proficiency tests, i.e. IELTS and TOEFL tests, and one local English proficiency test, i.e. TOLIMO from pragmatic perspective. An attempt was made to explore the areas of pragmatic knowledge presented, and to assess test takers' pragmatic knowledge. For…
Item Response Theory Models for Performance Decline during Testing
ERIC Educational Resources Information Center
Jin, Kuan-Yu; Wang, Wen-Chung
2014-01-01
Sometimes, test-takers may not be able to attempt all items to the best of their ability (with full effort) due to personal factors (e.g., low motivation) or testing conditions (e.g., time limit), resulting in poor performances on certain items, especially those located toward the end of a test. Standard item response theory (IRT) models fail to…
14 CFR 33.93 - Teardown inspection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... completing the endurance testing of § 33.87 (b), (c), (d), (e), or (g) of this part, each engine must be...) After completing the endurance testing of § 33.87(f), each engine must be completely disassembled, and... endurance testing of §§ 33.87 (b), (c), (d), or (e) of this part, and followed by the testing of § 33.87(f...
14 CFR 33.93 - Teardown inspection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... completing the endurance testing of § 33.87 (b), (c), (d), (e), or (g) of this part, each engine must be...) After completing the endurance testing of § 33.87(f), each engine must be completely disassembled, and... endurance testing of §§ 33.87 (b), (c), (d), or (e) of this part, and followed by the testing of § 33.87(f...
Ignitability analysis using the cone calorimeter and lift apparatus
Mark A. Dietenberger
1996-01-01
The irradiance plotted as function of time to ignition for wood materials tested in the Cone Calorimeter (ASTM E1354) differs signiticantly from that tested in the Lateral Ignition and Flame spread Test (LIFT) apparatus (ASTM E1321). This difference in piloted ignitabilty is primarily due to the difference in forced convective cooling of the specimen tested in both...
ERIC Educational Resources Information Center
Barkaoui, Khaled
2017-01-01
As the number of candidates who repeat English language proficiency tests more than once to meet a certain cutscore (e.g., for university admission) or to demonstrate progress (e.g., after instruction) continues to increase dramatically, there is a need for more research on the attributes and test performance of test repeaters. This article…
Department of Defense In-House RDT and E Activities
1977-10-30
SUPPRFSSI’N CWAMRFR, CAM EVAL & REF CEN, FUEL CELL t RTRY TEST STAS, ELEC PROPULSTON KTM, MPPS POWER TEST CELLS, nFRG TEST HANGAR, MORILE STRESS ANAL...TRIDENT,6S8,ETC) DESGNDEV E FVAL OF U/W TARGET SYSTEMS C MORILE /FIXD U/H TEST RANGES INTRODUCE TO FLEET C IN-SERVICE ENGINEERING OF MK 4S
40 CFR Appendix I to Subparts D... - Motorcycle Noise Emission Test Procedures
Code of Federal Regulations, 2011 CFR
2011-07-01
... Procedures I Appendix I to Subparts D and E of Part 205 Protection of Environment ENVIRONMENTAL PROTECTION... Exhaust Systems Remedial orders. Pt. 205, Subpts. D-E, App. I Appendix I to Subparts D and E of Part 205—Motorcycle Noise Emission Test Procedures Appendix I-1 to Subparts D and E—Test Procedure for Street and off...
40 CFR Appendix I to Subparts D... - Motorcycle Noise Emission Test Procedures
Code of Federal Regulations, 2010 CFR
2010-07-01
... Procedures I Appendix I to Subparts D and E of Part 205 Protection of Environment ENVIRONMENTAL PROTECTION... Exhaust Systems Remedial orders. Pt. 205, Subpts. D-E, App. I Appendix I to Subparts D and E of Part 205—Motorcycle Noise Emission Test Procedures Appendix I-1 to Subparts D and E—Test Procedure for Street and off...
49 CFR 40.251 - What are the first steps in an alcohol confirmation test?
Code of Federal Regulations, 2012 CFR
2012-10-01
... anything (e.g., cigarette, chewing gum) into his or her mouth, or belch; (ii) The reason for the waiting period (i.e., to prevent an accumulation of mouth alcohol from leading to an artificially high reading... is a refusal to test. (e) Even if more than 30 minutes have passed since the screening test result...
49 CFR 40.251 - What are the first steps in an alcohol confirmation test?
Code of Federal Regulations, 2014 CFR
2014-10-01
... anything (e.g., cigarette, chewing gum) into his or her mouth, or belch; (ii) The reason for the waiting period (i.e., to prevent an accumulation of mouth alcohol from leading to an artificially high reading... is a refusal to test. (e) Even if more than 30 minutes have passed since the screening test result...
49 CFR 40.251 - What are the first steps in an alcohol confirmation test?
Code of Federal Regulations, 2011 CFR
2011-10-01
... anything (e.g., cigarette, chewing gum) into his or her mouth, or belch; (ii) The reason for the waiting period (i.e., to prevent an accumulation of mouth alcohol from leading to an artificially high reading... is a refusal to test. (e) Even if more than 30 minutes have passed since the screening test result...
49 CFR 40.251 - What are the first steps in an alcohol confirmation test?
Code of Federal Regulations, 2013 CFR
2013-10-01
... anything (e.g., cigarette, chewing gum) into his or her mouth, or belch; (ii) The reason for the waiting period (i.e., to prevent an accumulation of mouth alcohol from leading to an artificially high reading... is a refusal to test. (e) Even if more than 30 minutes have passed since the screening test result...
Piirilä, P; Kanerva, L; Alanko, K; Estlander, T; Keskinen, H; Pajari-Backas, M; Tuppurainen, M
1999-03-01
We report on IgE-mediated asthma, rhinoconjunctivitis, and contact urticaria to two Liliaceae plants, tulip and Easter lily (Lilium longiflorum), diagnosed in a floral shop worker. Occupational asthma was diagnosed according to patient history, PEF monitoring, and a work-simulating provocation test. Flower-specific IgE was studied, and RAST inhibition tests were performed. Skin prick testing showed positive reactions to tulip, Easter lily, and chrysanthemum. Total IgE was 180 kU/I, and specific IgE to tulip was 2.6 and to Easter lily 6.5 kU/I. In the RAST-inhibition test, no cross-reactivity was found. Occupational asthma was diagnosed by peak flow monitoring at work and at home, as well as specific inhalation challenge with Easter lily, with an immediate 18% reduction in PEF. In addition, contact urticaria and conjunctivitis were diagnosed. After a 9-year follow-up without exposure to lilies, the skin prick tests to L. longiflorum and tulip were still positive, but the specific IgE had disappeared. A case of IgE-mediated occupational asthma, rhinoconjunctivitis, and contact urticaria caused by L. longiflorum and tulip is presented. RAST inhibition tests indicated concomitant sensitization to the two Liliaceae plants.
Credit BG. View looking northeast at southwestern side of Test ...
Credit BG. View looking northeast at southwestern side of Test Stand "D" complex. Test Stand "D" workshop (Building 4222/E-23) is at left; shed to its immediate right is an entrance to underground tunnel system which interconnects all test stands. To the right of Test Stand "D" tower are four Clayton water-tube flash boilers once used in the Steam Generator Plant 4280/E-81 to power the vacuum ejector system at "D" and "C" stands. A corner of 4280/E-81 appears behind the boilers. Boilers were removed as part of stand dismantling program. The Dv (vertical vacuum) Test Cell is located in the Test Stand "D" tower, behind the sunscreen on the west side. The top of the tower contains a hoist for lifting or lowering rocket engines into the Dv Cell. Other equipment mounted in the tower is part of the steam-driven vacuum ejector system - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA
Phenotypic Detection of Metallo-β-Lactamase in Imipenem-Resistant Pseudomonas aeruginosa
Khosravi, Yalda; Loke, Mun Fai; Chua, Eng Guan; Tay, Sun Tee; Vadivelu, Jamuna
2012-01-01
Carbapenems are the primary choice of treatment for severe Pseudomonas aeruginosa infection. However, the emergence of carbapenem resistance due to the production of metallo-β-lactamases (MBLs) is of global concern. In this study, 90 imipenem- (IPM- or IP-) resistant P. aeruginosa (IRPA) isolates, including 32 previously tested positive and genotyped for MBL genes by PCR, were subjected to double-disk synergy test (DDST), combined disk test (CDT), and imipenem/imipenem-inhibitor (IP/IPI) E-test to evaluate their MBLs detection capability. All three methods were shown to have a sensitivity of 100%. However, DDST was the most specific of the three (96.6%), followed by IP/IPI E-test interpreted based on the single criteria of IP/IPI ≥8 as positive (62.1%), and CDT was the least specific (43.1%). Based on the data from this evaluation, we propose that only IRPA with IP MIC >16 μg/mL and IP/IPI ≥8 by IP/IPI E-test should be taken as positive for MBL activity. With the new dual interpretation criteria, the MBL IP/IPI E-test was shown to achieve 100% sensitivity as well as specificity for the IRPA in this study. Therefore, the IP/IPI E-test is a viable alternative phenotypic assay to detect MBL production in IRPA in our population in circumstances where PCR detection is not a feasible option. PMID:22792048
9. Credit JPL. Photographic copy of drawing, engineering drawing showing ...
9. Credit JPL. Photographic copy of drawing, engineering drawing showing structure of Test Stand 'A' (Building 4202/E-3) and its relationship to the Monitor Building or blockhouse (Building 4203/E-4) when a reinforced concrete machinery room was added to the west side of Test Stand 'A' in 1955. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Electrical Layout - Muroc, Test Stand & Refrigeration Equipment Room,' drawing no. E3/7-0, April 6, 1955. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA
Philpott, H; Nandurkar, S; Royce, S G; Thien, F; Gibson, P R
2016-08-01
The use of allergy tests to guide dietary treatment for eosinophilic oesophagitis (EoE) is controversial and data are limited. Aeroallergen sensitisation patterns and food triggers have been defined in Northern Hemisphere cohorts only. To determine if allergy tests that are routinely available can predict food triggers in adult patients with EoE. To define the food triggers and aeroallergen sensitisation patterns in a novel Southern Hemisphere (Australian) cohort of patients. Consecutive patients with EoE who elected to undergo dietary therapy were prospectively assessed, demographic details and atopic characteristics recorded, and allergy tests, comprising skin-prick and skin-patch tests, serum allergen-specific IgE, basophil activation test and serum food-specific IgG, were performed. Patients underwent a six-food elimination diet with a structured algorithm that included endoscopic and histological examination of the oesophagus a minimum of 2 weeks after each challenge. Response was defined as <15 eosinophils per HPF. Foods defined as triggers were considered as gold standard and were compared with those identified by allergy testing. No allergy test could accurately predict actual food triggers. Concordance among skin-prick and serum allergen-specific IgE was high for aeroallergens only. Among seasonal aeroallergens, rye-grass sensitisation was predominant. Food triggers were commonly wheat, milk and egg, alone or in combination. None of the currently-available allergy tests predicts food triggers for EoE. Exclusion-rechallenge methodology with oesophageal histological assessment remains the only effective investigation. The same food triggers were identified in this southern hemisphere cohort as previously described. © 2016 John Wiley & Sons Ltd.
Bisanzi, Simonetta; Allia, Elena; Mongia, Alessandra; Carozzi, Francesca; Gillio-Tos, Anna; De Marco, Laura; Ronco, Guglielmo; Gustinucci, Daniela; Del Mistro, Annarosa; Frayle, Helena; Iossa, Anna; Fantacci, Giulia; Pompeo, Giampaolo; Cesarini, Elena; Bulletti, Simonetta; Passamonti, Basilio; Rizzi, Martina; Penon, Maria Gabriella; Barca, Alessandra; Benevolo, Maria
2017-01-01
ABSTRACT Cervical cancer screening by human papillomavirus (HPV) DNA testing with cytology triage is more effective than cytology testing. Compared to cytology, the HPV DNA test's higher sensitivity, which allows better protection with longer intervals, makes it necessary to triage the women with a positive result to compensate its lower specificity. We are conducting a large randomized clinical trial (New Technologies for Cervical Cancer 2 [NTCC2]) within organized population-based screening programs in Italy using HPV DNA as the primary screening test to evaluate, by the Aptima HPV assay (Hologic), the use of HPV E6-E7 mRNA in a triage test in comparison to cytology. By the end of June 2016, data were available for 35,877 of 38,535 enrolled women, 2,651 (7.4%) of whom were HPV DNA positive. Among the samples obtained, 2,453 samples were tested also by Aptima, and 1,649 (67.2%) gave a positive result. The proportion of mRNA positivity was slightly higher among samples tested for HPV DNA by the Cobas 4800 HPV assay (Roche) than by the Hybrid Capture 2 (HC2) assay (Qiagen). In our setting, the observed E6-E7 mRNA positivity rate, if used as a triage test, would bring a rate of immediate referral to colposcopy of about 4 to 5%. This value is higher than that observed with cytology triage for both immediate and delayed referrals to colposcopy. By showing only a very high sensitivity and thus allowing a longer interval for HPV DNA-positive/HPV mRNA-negative women, a triage by this test might be more efficient than by cytology. PMID:28100595
E-Learning Development Process for Operating System Course in Vocational School
NASA Astrophysics Data System (ADS)
Tuna, J. R.; Manoppo, C. T. M.; Kaparang, D. R.; Mewengkang, A.
2018-02-01
This development research aims to produce learning media in the form of E- Learning media using Edmodo which is interesting, efficient and effective on the subjects of operating system for students of class X TKJ in SMKN 3 Manado. The development model used was developed by S. Thiagarajan et al., Often known as the Four-D model, but this research only uses (define, design, and develop). Trial of the product is done twice (limited and wide). The experimental design used was the before-after experimental design. Data collection techniques used are interview techniques, questionnaires, and tests. The analytical technique used in this development research is descriptive qualitative. These include analysis of attractiveness test, efficiency and effectiveness of E-Learning media using Edmodo. The media attractiveness test was measured using a student response questionnaire. Media efficiency test was obtained through interviews of researchers with operating system subjects teachers and students of class X TKJ 1 at SMKN 3 Manado. While the media effectiveness test obtained from student learning outcomes before and after applying E-Learning media using Edomodo. Then tested by paired sample t test formula. After the media was piloted on the subject of trials (limited and broad), and the results show that E-Learning media using Edmodo is interesting, efficient and effective. It is shown on average student response score of 88.15% with very interesting interpretation. While the average value of student learning outcomes increased from 76.33 to 82.93. The results of differential test (paired sample t-test) the value of t = 11 217 ≥ ttable = 2,045 with significant value = 0.000 <α = 0.050 showing the media E -Learning using Edmodo is effective.
Facility Activation and Characterization for IPD Turbopump Testing at NASA Stennis Space Center
NASA Technical Reports Server (NTRS)
Sass, J. P.; Pace, J. S.; Raines, N. G.; Meredith, T. O.; Taylor, S. A.; Ryan, H. M.
2005-01-01
The Integrated Powerhead Demonstrator (IPD) is a 250K lbf (1.1 MN) thrust cryogenic hydrogen/oxygen engine technology demonstrator that utilizes a full flow staged combustion engine cycle. The Integrated Powerhead Demonstrator (IPD) is, in part, supported by NASA. IPD is also supported through the Department of Defense's Integrated High Payoff Rocket Propulsion Technology (IHPRPT) program, which seeks to increase the performance and capability of today's state-of-the-art rocket propulsion systems while decreasing costs associated with military and commercial access to space. The primary industry participants include Boeing-Rocketdyne and GenCorp Aerojet. The IPD Program recently achieved two major milestones. The first was the successful completion of the IPD Oxidizer Turbopump (OTP) hot-fire test project at the NASA John C. Stennis Space Center (SSC) E-1 test facility in June 2003. A total of nine IPD Workhorse Preburner tests were completed, and subsequently 12 IPD OTP hot-fire tests were completed. The second major milestone was the successful completion of the IPD Fuel Turbopump (FTP) cold-flow test project at the NASA SSC E-1 test facility in November 2003. A total of six IPD FTP cold-flow tests were completed. The next phase of development involves IPD integrated engine system testing also at the NASA SSC E-1 test facility scheduled to begin in early 2005. Following and overview of the NASA SSC E-1 test facility, this paper addresses the facility aspects pertaining to the activation and testing of the IPD oxidizer and fuel turbopumps. In addition, some of the facility challenges encountered and the lessons learned during the test projects shall be detailed.
Yang, Hyeon-Jong; Park, Min-Ju; Youn, Seo Young; Yoo, Sangsoo; Min, Taek Ki; Jeon, You Hoon; Lee, Hae Won; Lee, Ji Sung; Pyun, Bok Yang
2014-06-01
The skin prick test (SPT) for detecting atopic sensitization is not preferred in young infants with atopic dermatitis (AD) because of concerns about poor skin reactivity. This study aimed to evaluate whether the results of SPT agreed well with those of specific serum immunoglobulin E (sIgE) antibody test in young infants with AD. This study included 2,077 eligible infants (age, <12 months) with AD who were tested by either SPT or sIgE between 2007 and 2011. Among them, 199 infants tested for egg white (EW) and 192 infants tested for cow's milk (CM), by both SPT and sIgE on the same day were identified and reviewed retrospectively. Kappa statistics and tests for equal kappa statistics were used to evaluate the agreement between the SPT and sIgE. The mean wheal diameter and the allergen-to-histamine ratio of SPT showed substantial agreement with those of sIgE for EW (κ = 0.62, 0.69) and CM (κ = 0.34, 0.47). The agreement for EW was significantly higher <6-month-old than in ≥6-month-old infants (κ = 0.79 vs. 0.54, P = 0.02), and that for CM was similar (P = 0.60). The mean wheal diameters for EW and CM were evenly distributed, and did not show increasing trends regardless of age in months (Ptrend = 0.13 and 0.06, respectively). The results of SPT agreed well with those of sIgE. This finding provides a rationale for using SPT, and suggests that SPT can be used along with sIgE to detect food sensitization in young infants with AD.
Emerging and Disruptive Technologies.
Kricka, Larry J
2016-08-01
Several emerging or disruptive technologies can be identified that might, at some point in the future, displace established laboratory medicine technologies and practices. These include increased automation in the form of robots, 3-D printing, technology convergence (e.g., plug-in glucose meters for smart phones), new point-of-care technologies (e.g., contact lenses with sensors, digital and wireless enabled pregnancy tests) and testing locations (e.g., Retail Health Clinics, new at-home testing formats), new types of specimens (e.g., cell free DNA), big biology/data (e.g., million genome projects), and new regulations (e.g., for laboratory developed tests). In addition, there are many emerging technologies (e.g., planar arrays, mass spectrometry) that might find even broader application in the future and therefore also disrupt current practice. One interesting source of disruptive technology may prove to be the Qualcomm Tricorder XPrize, currently in its final stages.
Emerging and Disruptive Technologies
2016-01-01
Several emerging or disruptive technologies can be identified that might, at some point in the future, displace established laboratory medicine technologies and practices. These include increased automation in the form of robots, 3-D printing, technology convergence (e.g., plug-in glucose meters for smart phones), new point-of-care technologies (e.g., contact lenses with sensors, digital and wireless enabled pregnancy tests) and testing locations (e.g., Retail Health Clinics, new at-home testing formats), new types of specimens (e.g., cell free DNA), big biology/data (e.g., million genome projects), and new regulations (e.g., for laboratory developed tests). In addition, there are many emerging technologies (e.g., planar arrays, mass spectrometry) that might find even broader application in the future and therefore also disrupt current practice. One interesting source of disruptive technology may prove to be the Qualcomm Tricorder XPrize, currently in its final stages. PMID:27683538
Bisschop, Cornelis; ter Elst, Arja; Bosman, Lisette J.; Platteel, Inge; Jalving, Mathilde; van den Berg, Anke; Diepstra, Arjan; van Hemel, Bettien; Diercks, Gilles F.H.; Hospers, Geke A.P.
2018-01-01
BRAF mutational testing has become a common practice in the diagnostic process of patients with advanced melanoma. Although time-consuming, DNA sequencing techniques are the current gold standard for mutational testing. However, in certain clinical situations, a rapid test result is required. In this study, the performance of three rapid BRAF mutation tests was compared. Thirty-nine formalin-fixed paraffin-embedded melanoma tissue samples collected between 2007 and 2014 at a single center were included. These samples were analyzed by immunohistochemistry using the anti-BRAF-V600E (VE1) mouse monocolonal antibody (BRAF-VE1 IHC), a V600E-specific Droplet Digital PCR Test, and the Idylla BRAF- Mutation Test (Idylla). Results were compared with the results of conventional BRAF mutation testing, performed using high-resolution melting analysis followed by Sanger sequencing. Next-generation sequencing was performed on samples with discordant results. The Idylla test and Droplet Digital PCR Test correctly identified all mutated and wild-type samples. BRAF-VE1 IHC showed one discordant result. The Idylla test could identify BRAF-V600 mutations other than BRAF-V600E and was the fastest and least laborious test. The Idylla Mutation Test is the most suitable test for rapid BRAF testing in clinical situations on the basis of the broad coverage of treatment-responsive mutations and the fast procedure without the need to perform a DNA isolation step. PMID:29232304
1981-12-15
for 6o7e (B), which became slightly more platykurtic . Thus, there appeared to be a learning effect transferred from MCAT1 to MCAT2 resulting in higher... platykurtic ) except for positive 0.27 for OKT 102E. There was a more uniform distilbution of scores for the OKT than for the MCAT tests. The test scoies
Advanced Stirling Convertor (ASC-E2) Characterization Testing
NASA Technical Reports Server (NTRS)
Williams, Zachary D.; Oriti, Salvatore M.
2012-01-01
Testing has been conducted on Advanced Stirling Convertors (ASCs)-E2 at NASA Glenn Research Center in support of the Advanced Stirling Radioisotope Generator (ASRG) project. This testing has been conducted to understand sensitivities of convertor parameters due to environmental and operational changes during operation of the ASRG in missions to space. This paper summarizes test results and explains the operation of the ASRG during space missions
2017-01-01
procedures and Army doctrine. During pre -IOT&E training and developmental testing , the combat developer discovered that when projectiles were fired using...Director, Operational Test and Evaluation M109 Family of Vehicles, Paladin Integrated Management (PIM) Operational Assessment of the...Initial Operational Test and Evaluation October 2011 January 2017 J. Michael Gilmore Director
Dynamic memory searches: Selective output interference for the memory of facts.
Aue, William R; Criss, Amy H; Prince, Melissa A
2015-12-01
The benefits of testing on later memory performance are well documented; however, the manner in which testing harms memory performance is less well understood. This research is concerned with the finding that accuracy decreases over the course of testing, a phenomena termed "output interference" (OI). OI has primarily been investigated with episodic memory, but there is limited research investigating OI in measures of semantic memory (i.e., knowledge). In the current study, participants were twice tested for their knowledge of factual questions; they received corrective feedback during the first test. No OI was observed during the first test, when participants presumably searched semantic memory to answer the general-knowledge questions. During the second test, OI was observed. Conditional analyses of Test 2 performance revealed that OI was largely isolated to questions answered incorrectly during Test 1. These were questions for which participants needed to rely on recent experience (i.e., the feedback in episodic memory) to respond correctly. One possible explanation is that episodic memory is more susceptible to the sort of interference generated during testing (e.g., gradual changes in context, encoding/updating of items) relative to semantic memory. Alternative explanations are considered.
NASA Technical Reports Server (NTRS)
Krause, David L.; Brewer, Ethan J.; Pawlik, Ralph
2013-01-01
This report provides test methodology details and qualitative results for the first structural benchmark creep test of an Advanced Stirling Convertor (ASC) heater head of ASC-E2 design heritage. The test article was recovered from a flight-like Microcast MarM-247 heater head specimen previously used in helium permeability testing. The test article was utilized for benchmark creep test rig preparation, wall thickness and diametral laser scan hardware metrological developments, and induction heater custom coil experiments. In addition, a benchmark creep test was performed, terminated after one week when through-thickness cracks propagated at thermocouple weld locations. Following this, it was used to develop a unique temperature measurement methodology using contact thermocouples, thereby enabling future benchmark testing to be performed without the use of conventional welded thermocouples, proven problematic for the alloy. This report includes an overview of heater head structural benchmark creep testing, the origin of this particular test article, test configuration developments accomplished using the test article, creep predictions for its benchmark creep test, qualitative structural benchmark creep test results, and a short summary.
Accurate and fast multiple-testing correction in eQTL studies.
Sul, Jae Hoon; Raj, Towfique; de Jong, Simone; de Bakker, Paul I W; Raychaudhuri, Soumya; Ophoff, Roel A; Stranger, Barbara E; Eskin, Eleazar; Han, Buhm
2015-06-04
In studies of expression quantitative trait loci (eQTLs), it is of increasing interest to identify eGenes, the genes whose expression levels are associated with variation at a particular genetic variant. Detecting eGenes is important for follow-up analyses and prioritization because genes are the main entities in biological processes. To detect eGenes, one typically focuses on the genetic variant with the minimum p value among all variants in cis with a gene and corrects for multiple testing to obtain a gene-level p value. For performing multiple-testing correction, a permutation test is widely used. Because of growing sample sizes of eQTL studies, however, the permutation test has become a computational bottleneck in eQTL studies. In this paper, we propose an efficient approach for correcting for multiple testing and assess eGene p values by utilizing a multivariate normal distribution. Our approach properly takes into account the linkage-disequilibrium structure among variants, and its time complexity is independent of sample size. By applying our small-sample correction techniques, our method achieves high accuracy in both small and large studies. We have shown that our method consistently produces extremely accurate p values (accuracy > 98%) for three human eQTL datasets with different sample sizes and SNP densities: the Genotype-Tissue Expression pilot dataset, the multi-region brain dataset, and the HapMap 3 dataset. Copyright © 2015 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.
14 CFR Appendix E to Part 43 - Altimeter System Test and Inspection
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Altimeter System Test and Inspection E Appendix E to Part 43 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT MAINTENANCE, PREVENTIVE MAINTENANCE, REBUILDING, AND ALTERATION Pt. 43, App. E Appendix E to Part...
Notched bar Izod impact properties of zinc die castings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schrems, K.K.; Dogan, O.N.; Goodwin, F.E.
2007-03-01
Notched bar Izod impact testing of zinc die cast Alloy 3, Alloy 5, ZA-8, and AcuZinc 5 was performed at five temperatures between -40\\mDC and room temperature in accordance with ASTM E23 for impact testing of metallic materials. A direct comparison between ASTM D256 for impact testing of plastics and ASTM E23 was performed using continuously cast zinc specimens of Alloy 5 and ZA-8 at -40\\mDC and room temperature. There are differences in sample sizes, impact velocity, and striker geometry between the two tests. Bulk zinc tested according to ASTM E23 resulted in higher impact energies at -40\\mDC and lowermore » impact energies at room temperature then did the same alloys when tested according to ASTM D256.« less
[Increase in orders for specific IgE tests and more positive results in children in 1985-2003].
Baatenburg de Jong, A; Dikkeschei, L D; Brand, P L P
2008-08-09
To describe changes over time in the number of allergy tests for specific IgE ordered and outcomes in children, to help address the question whether the increase in allergies is due to an actual increase in sensitisation or an increase in diagnostic awareness of allergies among physicians. Retrospective and descriptive. We reviewed the results of all specific IgE tests performed in our hospital's laboratory for children 0-18 years of age in the period 1985-2003. This included tests ordered by both general practitioners and hospital-based specialists. We analysed trends over time in the number of tests ordered (as an indicator ofdiagnostic awareness) and test results (as an indicator ofsensitisation). Between 1989 and 1995, the annual number of tests ordered increased from 1 per 10,000 children to 95 per 10,000 children and remained stable thereafter. Before 1990, more than 90% of tests were ordered by hospital-based specialists; after 1990, approximately 70% of the tests were ordered by general practitioners (p < 0.001). The proportion of positive tests remained stable at approximately 27% until 1991, after which it increased to more than 45% (p < 0.001). The increase in the proportion of positive tests suggests an increase in atopic sensitization between 1985 and 2000 which has stabilized since.
Fujimura, Masato; Masuda, Kenichi; Hayashiya, Makio; Okayama, Taro
2011-10-01
Two different allergy tests, antigen-specific immunoglobulin E quantification (IgE test) and flow cytometric analysis of antigen-specific proliferation of peripheral lymphocytes (lymphocyte proliferation test), were performed to examine differences in allergic reactions to food allergens in dogs with food allergy (FA). Thirteen dogs were diagnosed as FA based on clinical findings and elimination diet trials. Seven dogs clinically diagnosed with canine atopic dermatitis (CAD) were used as a disease control group, and 5 healthy dogs were used as a negative control group. In the FA group, 19 and 33 allergen reactions were identified using the serum IgE test and the lymphocyte proliferation test, respectively. Likewise, in the CAD group, 12 and 6 allergen reactions and in the healthy dogs 3 and 0 allergen reactions were identified by each test, respectively. A significant difference was found between FA and healthy dogs in terms of positive allergen detection by the lymphocyte proliferation test, suggesting that the test can be useful to differentiate FA from healthy dogs but not from CAD. Both tests were repeated in 6 of the dogs with FA after a 1.5- to 5-month elimination diet trial. The IgE concentrations in 9 of 11 of the positive reactions decreased by 20-80%, whereas all the positive reactions in the lymphocyte proliferation test decreased to nearly zero (P<0.05), suggesting that lymphocytes against food allergens may be involved in the pathogenesis of canine FA.
Advanced Stirling Convertor (ASC-E2) Performance Testing at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Oriti, Salvatore; Wilson, Scott
2011-01-01
The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG Project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, four pairs of ASCs capable of operating to 850 C and designated with the model number ASC-E2, were delivered by Sunpower of Athens, OH, to GRC in 2010. The ASC-E2s underwent a series of tests that included workmanship vibration testing, performance mapping, and extended operation. Workmanship vibration testing was performed following fabrication of each convertor to verify proper hardware build. Performance mapping consisted of operating each convertor at various conditions representing the range expected during a mission. Included were conditions representing beginning-of-mission (BOM), end-of-mission (EOM), and fueling. This same series of tests was performed by Sunpower prior to ASC-E2 delivery. The data generated during the GRC test were compared to performance before delivery. Extended operation consisted of a 500-hour period of operation with conditions maintained at the BOM point. This was performed to demonstrate steady convertor performance following performance mapping. Following this initial 500-hour period, the ASC-E2s will continue extended operation, controller development and special durability testing, during which the goal is to accumulate tens of thousands of hours of operation. Data collected during extended operation will support reliability analysis. Performance data from these tests is summarized in this paper.
Advanced Stirling Convertor (ASC-E2) Performance Testing at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Oriti, Salvatore; Wilson, Scott
2011-01-01
The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG Project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, four pairs of ASCs capable of operating to 850 C and designated with the model number ASC-E2, were delivered by Sunpower of Athens, Ohio, to GRC in 2010. The ASC-E2s underwent a series of tests that included workmanship vibration testing, performance mapping, and extended operation. Workmanship vibration testing was performed following fabrication of each convertor to verify proper hardware build. Performance mapping consisted of operating each convertor at various conditions representing the range expected during a mission. Included were conditions representing beginning-of-mission (BOM), end-of-mission (EOM), and fueling. This same series of tests was performed by Sunpower prior to ASC-E2 delivery. The data generated during the GRC test were compared to performance before delivery. Extended operation consisted of a 500-hr period of operation with conditions maintained at the BOM point. This was performed to demonstrate steady convertor performance following performance mapping. Following this initial 500-hr period, the ASC-E2s will continue extended operation, controller development and special durability testing, during which the goal is to accumulate tens of thousands of hours of operation. Data collected during extended operation will support reliability analysis. Performance data from these tests is summarized in this paper.
Van Hoeyveld, Erna; Nickmans, Silvie; Ceuppens, Jan L; Bossuyt, Xavier
2015-10-23
Cut-off values and predictive values are used for the clinical interpretation of specific IgE antibody results. However, cut-off levels are not well defined, and predictive values are dependent on the prevalence of disease. The objective of this study was to document clinically relevant diagnostic accuracy of specific IgE for inhalant allergens (grass pollen and birch pollen) based on test result interval-specific likelihood ratios. Likelihood ratios are independent of the prevalence and allow to provide diagnostic accuracy information for test result intervals. In a prospective study we included consecutive adult patients presenting at an allergy clinic with complaints of rhinitis or rhinoconjunctivitis. The standard for diagnosis was a suggestive clinical history of grass or birch pollen allergy and a positive skin test. Specific IgE was determined with the ImmunoCAP Fluorescence Enzyme Immuno-Assay. We established specific IgE test result interval related likelihood ratios for clinical allergy to inhalant allergens (grass pollen, rPhl p 1,5, birch pollen, rBet v 1). The likelihood ratios for allergy increased with increasing specific IgE antibody levels. The likelihood ratio was <0.03 for specific IgE <0.1 kU/L, between 0.1 and 1.4 for specific IgE between 0.1 kU/L and 0.35 kU/L, between 1.4 and 4.2 for specific IgE between 0.35 kU/L and 3.5 kU/L, >6.3 for specific IgE>0.7, and very high (∞) for specific IgE >3.5 kU/L. Test result interval specific likelihood ratios provide a useful tool for the interpretation of specific IgE test results for inhalant allergens. Copyright © 2015 Elsevier B.V. All rights reserved.
Clement, Stephen L.; Hu, Jinguo; Stewart, Alan V.; Wang, Bingrui; Elberson, Leslie R.
2011-01-01
Seed-borne Epichloë/Neotyphodium Glenn, Bacon, Hanlin (Ascomycota: Hypocreales: Clavicipitaceae) fungal endophytes in temperate grasses can provide protection against insect attack with the degree of host resistance related to the grass—endophyte symbiotum and the insect species involved in an interaction. Few experimental studies with wild grass—endophyte symbiota, compared to endophyte-infected agricultural grasses, have tested for anti-insect benefits, let alone for resistance against more than one insect species. This study quantified the preference and performance of the bird cherry oat-aphid, Rhopalosiphum padi (L.) (Hemiptera: Aphididae) and the cereal leaf beetle, Oulema melanopus (L.) (Coleoptera: Chrysomelidae), two important pests of forage and cereal grasses, on Neotyphodium-infected (E+) and uninfected (E-) plants of the wild grass Alpine timothy, Phleum alpinum L. (Poales: Poaceae). The experiments tested for both constitutive and wound-induced resistance in E+ plants to characterize possible plasticity of defense responses by a wild E+ grass. The aphid, R. padi preferred E- over E+ test plants in choice experiments and E+ undamaged test plants constitutively expressed antibiosis resistance to this aphid by suppressing population growth. Prior damage of E+ test plants did not induce higher levels of resistance to R. padi. By contrast, the beetle, O. melanopus showed no preference for E+ or E- test plants and endophyte infection did not adversely affect the survival and development of larvae. These results extend the phenomenon of variable effects of E+ wild grasses on the preference and performance of phytophagous insects. The wild grass— Neotyphodium symbiotum in this study broadens the number of wild E+ grasses available for expanded explorations into the effects of endophyte metabolites on insect herbivory. PMID:21867443
Clement, Stephen L; Hu, Jinguo; Stewart, Alan V; Wang, Bingrui; Elberson, Leslie R
2011-01-01
Seed-borne Epichloë/Neotyphodium Glenn, Bacon, Hanlin (Ascomycota: Hypocreales: Clavicipitaceae) fungal endophytes in temperate grasses can provide protection against insect attack with the degree of host resistance related to the grass-endophyte symbiotum and the insect species involved in an interaction. Few experimental studies with wild grass-endophyte symbiota, compared to endophyte-infected agricultural grasses, have tested for anti-insect benefits, let alone for resistance against more than one insect species. This study quantified the preference and performance of the bird cherry oat-aphid, Rhopalosiphum padi (L.) (Hemiptera: Aphididae) and the cereal leaf beetle, Oulema melanopus (L.) (Coleoptera: Chrysomelidae), two important pests of forage and cereal grasses, on Neotyphodium-infected (E+) and uninfected (E-) plants of the wild grass Alpine timothy, Phleum alpinum L. (Poales: Poaceae). The experiments tested for both constitutive and wound-induced resistance in E+ plants to characterize possible plasticity of defense responses by a wild E+ grass. The aphid, R. padi preferred E- over E+ test plants in choice experiments and E+ undamaged test plants constitutively expressed antibiosis resistance to this aphid by suppressing population growth. Prior damage of E+ test plants did not induce higher levels of resistance to R. padi. By contrast, the beetle, O. melanopus showed no preference for E+ or E- test plants and endophyte infection did not adversely affect the survival and development of larvae. These results extend the phenomenon of variable effects of E+ wild grasses on the preference and performance of phytophagous insects. The wild grass- Neotyphodium symbiotum in this study broadens the number of wild E+ grasses available for expanded explorations into the effects of endophyte metabolites on insect herbivory.
Yoo, Gu; Bong, Ji-Hong; Kim, Sinyoung; Jose, Joachim; Pyun, Jae-Chul
2014-07-15
A microarray-based immunoassay for the detection of autoantibodies against Ro protein was developed using Escherichia coli with autodisplayed Ro proteins (Ro(+)-E. coli). Patient serum usually contains various antibodies against the outer membrane components of E. coli as well as autoantibodies against the Ro protein. Therefore, the conventional immunoassay based on Ro(+)-E. coli requires both wild type E. coli (blank test) and Ro(+)-E. coli, and both strains of E. coli must be prepared in situ for each individual test serum. In this study, we tested the feasibility of using several types of animal sera as a replacement for individual human sera. An immunoassay without the blank test was developed using Ro(+)-E. coli by (1) blocking with rabbit serum, and (2) cleaving the Fc region from antibodies using papain. Modified E. coli with autodisplayed Ro protein was immobilized to a surface-modified microplate and the applicability of the immunoassay without the blank test was demonstrated using sera from patients with systemic lupus erythematosus (SLE). Using this approach, a microarray-based fluorescence immunoassay with immobilized Ro(+)-E. coli was able to detect anti-Ro autoantibodies in SLE patient sera with high specificity and selectivity and improved efficiency. Copyright © 2014 Elsevier B.V. All rights reserved.
Environmental Assisted Cracking in High Hardness Armor Steel
1985-09-01
Longitudinal and transverse tension tests (ASTM E8-81) utilizing flat dogbane specimens, and subsize Charpy impact tests (ASTM 23-81) were performed on part...had been obtained. Longitudinal and transverse tension tests (ASTM E8-81) utilizing flat dogbane specimens, and subsize Charpy impact tests (ASTM 23... Charpy and tensile bar surfaces. All of the optical metallography samples were prepared using standard metallographic practices. The optical specimens
High-Temperature Test Technology
1987-03-01
delivery methods are available for a test vehicle (e.g., flatbed )? What potential is there to expand the test area? 4. What provision is there for...Yes[- No-- If "yes," what are the dimensions? What delivery methods are available for a test vehicle (e.g., flatbed )? What potential is there to...or (c) air connections introducing additional convection losses, as required for ia) laminated sheet plastic curing. (b) paper dehydrating. (c) heat
SAS molecular tests Escherichia coli O157 detection kit. Performance tested method 031203.
Bapanpally, Chandra; Montier, Laura; Khan, Shah; Kasra, Akif; Brunelle, Sharon L
2014-01-01
The SAS Molecular tests Escherichia coli O157 Detection method, a loop-mediated isothermal amplification method, performed as well as or better than the U.S. Department of Agriculture, Food Safety Inspection Service Microbiology Laboratory Guidebook and the U.S. Food and Drug Administration Bacteriological Analytical Manual reference methods for ground beef, beef trim, bagged mixed lettuce, and fresh spinach. Ground beef (30% fat, 25 g test portion) was validated for 7-8 h enrichment, leafy greens were validated in a 6-7 h enrichment, and ground beef (30% fat, 375 g composite test portion) and beef trim (375 g composite test portion) were validated in a 16-20 h enrichment. The method performance for meat and leafy green matrixes was also shown to be acceptable under conditions of co-enrichment with Salmonella. Thus, after a short co-enrichment step, ground beef, beef trim, lettuce, and spinach can be tested for both Salmonella and E. coli O157. The SAS Molecular tests Salmonella Detection Kit was validated using the same test portions as for the SAS Molecular tests E. coli O157 Detection Kit and those results are presented in a separate report. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 50 E. coli 0157 strains, including H7 and non-motile strains, and 30 non-E. coli O157 strains examined. Finally, the method was shown to be robust when variations to DNA extract hold time and DNA volume were varied. The method comparison and robustness data suggest a full 7 h enrichment time should be used for 25 g ground beef test portions.
Volvo Penta 4.3 GL E15 Emissions and Durability Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zoubul, G.; Cahoon, M.; Kolb, R.
2011-10-01
A new Volvo Penta carbureted 4.3 GL engine underwent emissions and dynamometer durability testing from break-in to expected end of life using an accelerated ICOMIA marine emissions cycle and E15 fuel. Only ethanol content was controlled. All aging used splash-blended E15 fuel. Exhaust emissions, exhaust gas temperature, torque, power, barometric pressure, air temperature, and fuel flow were measured at five intervals using site-blended E15 aging fuel and certification fuel (E0). The durability test cycle showed no noticeable impact on mechanical durability or engine power. Emissions performance degraded beyond the certification limit for this engine family, mostly occurring by 28% ofmore » expected life. Such degradation is inconsistent with prior experience. Comparisons showed that E15 resulted in lower CO and HC, but increased NOX, as expected for non-feedback-controlled carbureted engines with increased oxygen in the fuel. Fuel consumption also increased with E15 compared with E0. Throughout testing, poor starting characteristics were exhibited on E15 fuel for hot re-start and cold-start. Cranking time to start and smooth idle was roughly doubled compared with typical E0 operation. The carburetor was factory-set for lean operation to ensure emissions compliance. Test protocols did not include carburetor adjustment to account for increased oxygen in the E15 fuel.« less
ERIC Educational Resources Information Center
Linderholm, Tracy; Dobson, John; Yarbrough, Mary Beth
2016-01-01
A testing-based learning strategy is one that relies on the act of recalling (i.e., testing) information after exposure, and interleaving is a strategy in which the learning materials are presented in a serial order (e.g., "texts 1, 2, 3, 1, 2, 3, 1, 2, 3") versus a blocked order (e.g., "texts 1, 1, 1, 2, 2, 2, 3, 3, 3").…
Software OT&E Guidelines. Volume 1. Software Test Manager’s Handbook
1981-02-01
on reverse side If neceeary and identify by block number) The Software OT&E Guidelines is a set of handbooks prepared by the Computer / Support Systems...is one of a set of handbooks prepared by the Computer /Support Systems Division of the Test and Evaluation Directorate, Air Force Test and Evaluation...15 E. Software Maintainability .. .. ........ ... 16 F. Standard Questionnaires. .. .. ....... .... 16 1. Operator- Computer Interface Evaluation
Microcomputer Control of a Hydraulically Actuated Piston.
1987-06-01
EhhhohEohEmhhE EhhmhhhohhhhhI M1l *2 112.2 Ll 6 111111.258 MICROCOPY RESOLUfION TEST CHART NATIONAL BUREAUJ nF SIANDARDS 1963 A W* %i r f U V ~ S i V...SYSTE.M............................I( E. I REQUENCY RESPONSE TEST ........................... F. MODEL V.ALIDATION ................................. 2...O RITH M (BA SIC) ................................. 43 APPENDIX D: DIGITAL SYSTEM SIMULATION CODE (DSL) ........... 44 APPENDIX E: DIGITAL LOGIC TEST
Performance of the dipstick screening test as a predictor of negative urine culture.
Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio Dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle
2017-01-01
To investigate whether the urine dipstick screening test can be used to predict urine culture results. A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. Verificar se a triagem de urina por fitas reativas é capaz de predizer a cultura de urina. Métodos Estudo retrospectivo realizado entre janeiro e dezembro de 2014 com 8.587 pacientes, com solicitação médica de triagem de urina (fita), sedimento urinário e cultura de urina. sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e curva ROC. Foram positivas 17,5% das culturas. O nitrito apresentou sensibilidade de 28% e especificidade de 99%. O valor preditivo positivo foi de 89% e o valor preditivo negativo de 87%. Esterase apresentou sensibilidade de 79% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram de 51% e 95%, respectivamente. A combinação de nitrito ou esterase positivos apresentou sensibilidade de 85% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram, respectivamente, 53% e 96%. O sedimento positivo (mais de dez leucócitos por microlitro) apresentou sensibilidade de 92% e especificidade de 71%. O valor preditivo positivo foi 40% e o negativo, 98%. A combinação de nitrito e sedimento urinário positivos apresentou sensibilidade de 82% e especificidade de 99%. Os valores preditivos positivo e negativo foram 91% e 98%, respectivamente. Para o nitrito ou esterase positivos mais os leucócitos positivos, a sensibilidade foi de 94% e a especificidade de 84%. O valor preditivo positivo foi de 58% e o negativo foi de 99%. Com base na curva ROC, o melhor indicador de urocultura positiva foi a associação entre a esterase ou nitrito positivos na fita mais os leucócitos positivos no sedimento, seguido por nitrito e esterase positivos, sedimento urinário positivo isolado, esterase positiva isolada, nitrito positivo isolado e, finalmente, pela associação entre nitrito e sedimento urinário positivos (AUC: 0,845, 0,844, 0,817, 0,814, 0,635 e 0,626, respectivamente). Uma urocultura negativa pode ser prevista com resultados negativos na fita. Portanto, este teste pode ser um preditor confiável de urocultura negativa.
Performance of OncoE6 cervical test with collection methods enabling self-sampling.
Krings, Amrei; Dückelmann, Anna M; Moser, Lutz; Gollrad, Johannes; Wiegerinck, Maarten; Schweizer, Johannes; Kaufmann, Andreas M
2018-05-21
The paradigm shift from cytological screening to Human Papillomavirus (HPV)-based screening for cervical cancer allows the introduction of new technologies in sample collection and diagnostics. The OncoE6™ Cervical Test (OncoE6 Test) is a rapid, easy-to-use lateral flow method detecting HPV16/18 E6 oncoproteins that has proven to detect high-grade cervical lesions with high specificity. If compatible with self-collection samples, this technology might allow for decentralized screening of hard-to-reach populations. For technical validation, cervicovaginal lavages were collected from 20 patients with confirmed HPV16+ or HPV18+ invasive cervical cancer. Cervical smears were collected by polyester-tipped swabs and cytobrushes. All samples were applied to the OncoE6 Test and cytobrush samples additionally genotyped. Lavage, swab, and cytobrush revealed concordant outcome in 18/20 samples. HPV types corresponded with the HPV genotyping by GP5+/6+ PCR analyses. Due to a rare mutation found in the E6 antibody binding site one sample was not detected, another sample had very low cellularity. Overall, vaginal lavages are technically adequate for the OncoE6 Test. Combining self-sampling with oncoprotein rapid testing to detect women with highest risk for severe dysplasia or cancer may allow for secondary cancer prevention in settings where other screening modalities were unsuccessful to date.
Development of load spectra for Airbus A330/A340 full scale fatigue tests
NASA Technical Reports Server (NTRS)
Schmidt, H.-J.; Nielsen, Thomas
1994-01-01
For substantiation of the recently certified medium range Airbus A330 and long range A340 the full scale fatigue tests are in progress. The airframe structures of both aircraft types are tested by one set of A340 specimens. The development of the fatigue test spectra for the two major test specimens which are the center fuselage and wing test and the rear fuselage test is described. The applied test load spectra allow a realistic simulation of flight, ground and pressurization loads and the finalization of the tests within the pre-defined test period. The paper contains details about the 1 g and incremental flight and ground loads and the establishment of the flight-by-flight test program, i.e., the definition of flight types, distribution of loads within the flights and randomization of flight types in repeated blocks. Special attention is given to procedures applied for acceleration of the tests, e.g. omission of lower spectrum loads and a general increase of all loads by ten percent.
Explicit versus Implicit Social Cognition Testing in Autism Spectrum Disorder
ERIC Educational Resources Information Center
Callenmark, Björn; Kjellin, Lars; Rönnqvist, Louise; Bölte, Sven
2014-01-01
Although autism spectrum disorder is defined by reciprocal social-communication impairments, several studies have found no evidence for altered social cognition test performance. This study examined explicit (i.e. prompted) and implicit (i.e. spontaneous) variants of social cognition testing in autism spectrum disorder. A sample of 19 adolescents…
40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter (L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...
40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter (L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...
40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter ( L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...
TEST (Toxicity Estimation Software Tool) Ver 4.1
The Toxicity Estimation Software Tool (T.E.S.T.) has been developed to allow users to easily estimate toxicity and physical properties using a variety of QSAR methodologies. T.E.S.T allows a user to estimate toxicity without requiring any external programs. Users can input a chem...
49 CFR Appendix E to Part 227 - Use of Insert Earphones for Audiometric Testing
Code of Federal Regulations, 2010 CFR
2010-10-01
... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION OCCUPATIONAL NOISE EXPOSURE Pt. 227, App. E Appendix.... B. Technicians who conduct audiometric tests must be trained to insert the earphones correctly into... audiometer. IV. Background Noise Levels Testing shall be conducted in a room where the background ambient...
Code of Federal Regulations, 2012 CFR
2012-07-01
... serve its intended function for 1 hour when subjected to a fire test incorporating an ASTM E119-88 time/temperature heat input, or equivalent. The publication ASTM E119-88 “Standard Test Methods for Fire Tests of... Wilson Blvd., Room 2352, Arlington, Virginia 22209-3939; or at the National Archives and Records...
Code of Federal Regulations, 2011 CFR
2011-07-01
... serve its intended function for 1 hour when subjected to a fire test incorporating an ASTM E119-88 time/temperature heat input, or equivalent. The publication ASTM E119-88 “Standard Test Methods for Fire Tests of... Wilson Blvd., Room 2352, Arlington, Virginia 22209-3939; or at the National Archives and Records...
Code of Federal Regulations, 2014 CFR
2014-07-01
... serve its intended function for 1 hour when subjected to a fire test incorporating an ASTM E119-88 time/temperature heat input, or equivalent. The publication ASTM E119-88 “Standard Test Methods for Fire Tests of... Wilson Blvd., Room 2352, Arlington, Virginia 22209-3939; or at the National Archives and Records...
Code of Federal Regulations, 2013 CFR
2013-07-01
... serve its intended function for 1 hour when subjected to a fire test incorporating an ASTM E119-88 time/temperature heat input, or equivalent. The publication ASTM E119-88 “Standard Test Methods for Fire Tests of... Wilson Blvd., Room 2352, Arlington, Virginia 22209-3939; or at the National Archives and Records...
Photographic copy of photograph, aerial view looking down at Jet ...
Photographic copy of photograph, aerial view looking down at Jet Propulsion Laboratory, Edwards Test Station complex in 1961, with north toward the top of the view. Dd test station has been added to Test Stand 'D,' liquid nitrogen storage facility E-63 has been built, as well as several adjuncts to Test Stand 'C' behind earth barriers, such as oxidizer facility at 4263/E-64 and hydrogen tank at 4264/E-65. (JPL negative no. 384-3003-A, 12 December 1961) - Jet Propulsion Laboratory Edwards Facility, Edwards Air Force Base, Boron, Kern County, CA
Iritani, B; Inzana, T J
1988-01-01
Three hundred sixty-six isolates of gram-negative, oxidase-negative bacteria from veterinary specimens were tested by a tube test for identification as Escherichia coli by production within 60 min of indole, beta-galactosidase, and beta-glucuronidase. The test correctly identified 255 of 269 isolates of E. coli (95% sensitivity) and correctly indicated that 97 of 97 isolates were not E. coli (100% specificity). We conclude that production of indole, beta-galactosidase, and beta-glucuronidase as measured by a rapid tube test is useful for identification of E. coli from veterinary specimens. PMID:3128581
Wilson, Emma; Free, Caroline; Morris, Tim P; Syred, Jonathan; Ahamed, Irrfan; Menon-Johansson, Anatole S; Palmer, Melissa J; Barnard, Sharmani; Rezel, Emma; Baraitser, Paula
2017-12-01
Internet-accessed sexually transmitted infection testing (e-STI testing) is increasingly available as an alternative to testing in clinics. Typically this testing modality enables users to order a test kit from a virtual service (via a website or app), collect their own samples, return test samples to a laboratory, and be notified of their results by short message service (SMS) or telephone. e-STI testing is assumed to increase access to testing in comparison with face-to-face services, but the evidence is unclear. We conducted a randomised controlled trial to assess the effectiveness of an e-STI testing and results service (chlamydia, gonorrhoea, HIV, and syphilis) on STI testing uptake and STI cases diagnosed. The study took place in the London boroughs of Lambeth and Southwark. Between 24 November 2014 and 31 August 2015, we recruited 2,072 participants, aged 16-30 years, who were resident in these boroughs, had at least 1 sexual partner in the last 12 months, stated willingness to take an STI test, and had access to the internet. Those unable to provide consent and unable to read English were excluded. Participants were randomly allocated to receive 1 text message with the web link of an e-STI testing and results service (intervention group) or to receive 1 text message with the web link of a bespoke website listing the locations, contact details, and websites of 7 local sexual health clinics (control group). Participants were free to use any other services or interventions during the study period. The primary outcomes were self-reported STI testing at 6 weeks, verified by patient record checks, and self-reported STI diagnosis at 6 weeks, verified by patient record checks. Secondary outcomes were the proportion of participants prescribed treatment for an STI, time from randomisation to completion of an STI test, and time from randomisation to treatment of an STI. Participants were sent a £10 cash incentive on submission of self-reported data. We completed all follow-up, including patient record checks, by 17 June 2016. Uptake of STI testing was increased in the intervention group at 6 weeks (50.0% versus 26.6%, relative risk [RR] 1.87, 95% CI 1.63 to 2.15, P < 0.001). The proportion of participants diagnosed was 2.8% in the intervention group versus 1.4% in the control group (RR 2.10, 95% CI 0.94 to 4.70, P = 0.079). No evidence of heterogeneity was observed for any of the pre-specified subgroup analyses. The proportion of participants treated was 1.1% in the intervention group versus 0.7% in the control group (RR 1.72, 95% CI 0.71 to 4.16, P = 0.231). Time to test, was shorter in the intervention group compared to the control group (28.8 days versus 36.5 days, P < 0.001, test for difference in restricted mean survival time [RMST]), but no differences were observed for time to treatment (83.2 days versus 83.5 days, P = 0.51, test for difference in RMST). We were unable to recruit the planned 3,000 participants and therefore lacked power for the analyses of STI diagnoses and STI cases treated. The e-STI testing service increased uptake of STI testing for all groups including high-risk groups. The intervention required people to attend clinic for treatment and did not reduce time to treatment. Service innovations to improve treatment rates for those diagnosed online are required and could include e-treatment and postal treatment services. e-STI testing services require long-term monitoring and evaluation. ISRCTN Registry ISRCTN13354298.
Martorell, A; García Ara, M C; Plaza, A M; Boné, J; Nevot, S; Echeverria, L; Alonso, E; Garde, J
2008-01-01
Immunoglobulin E-mediated allergy to cow's milk protein (CMP) tends to subside over years of follow-up. The gold standard for detecting such allergy has been the oral challenge test. The development of some other test for determining the correct timing of the oral challenge test would avoid unnecessary patient discomfort. The aim of this study was to determine whether monitoring cow's milk (CM) specific IgE levels over time can be used as a predictor for determining when patients develop clinical tolerance. A prospective 4-year follow-up study was made of 170 patients with IgE-mediated allergy to CMP, involving periodic evaluations (12, 18, 24, 36 and 48 months) with the determination of casein and CM specific IgE on each visit, along with CM challenge testing. ROC curves were used to analyse the sensitivity, specificity and predictive values of the casein and CM specific IgE levels versus the challenge test outcomes at the different moments of follow-up. In the course of follow-up, 140 infants (82 %) became tolerant. Specific IgE levels to CM: 2.58, 2.5, 2.7, 2.26, 5 kU(A)/l and to casein: 0.97, 1.22, 3, 2.39, 2.73 kU(A)/l, respectively, predicted clinical reactivity (greatest diagnostic efficiency values) at the different analysed moments of follow-up (12, 18, 24, 36 and 48 months). Quantification of CMP specific IgE is a useful test for diagnosing symptomatic allergy to CM in the paediatric population, and could eliminate the need to perform oral challenges tests in a significant number of children.
Castro, Gabriel Perfeito; Medeiros, Daniel de Castro; Guarnieri, Leonardo de Oliveira; Mourão, Flávio Afonso Gonçalves; Pinto, Hyorrana Priscila Pereira; Pereira, Grace Schenatto; Moraes, Márcio Flávio Dutra
2017-06-01
Accumulating evidence from different animal models has contributed to the understanding of the bidirectional comorbidity associations between the epileptic condition and behavioral abnormalities. A strain of animals inbred to enhance seizure predisposition to high-intensity sound stimulation, the Wistar audiogenic rat (WAR), underwent several behavioral tests: forced swim test (FST), open-field test (OFT), sucrose preference test (SPT), elevated plus maze (EPM), social preference (SP), marble burying test (MBT), inhibitory avoidance (IAT), and two-way active avoidance (TWAA). The choice of tests aimed to investigate the correlation between underlying circuits believed to be participating in both WAR's innate susceptibility to sound-triggered seizures and the neurobiological substrates associated with test performance. Comparing WAR with its Wistar counterpart (i.e., resistant to audiogenic seizures) showed that WARs present behavioral despair traits (e.g., increased FST immobility) but no evidence of anhedonic behavior (e.g., increased sucrose consumption in SPT) or social impairment (e.g., no difference regarding juvenile exploration in SP). In addition, tests suggested that WARs are unable to properly evaluate degrees of aversiveness (e.g., performance on OFT, EPM, MBT, IAT, and TWAA). The particularities of the WAR model opens new venues to further untangle the neurobiology underlying the co-morbidity of behavioral disorders and epilepsy. This article is part of a Special Issue entitled "Genetic and Reflex Epilepsies, Audiogenic Seizures and Strains: From Experimental Models to the Clinic". Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raimondo, E.; Capman, J.L.; Herovard, M.
1985-05-01
Requirements for qualification of electrical equipment used in French-built nuclear power plants are stated in a national code, the RCC-E, or Regles de Construction et de Conception des Materiels Electriques. Under the RCC-E, safety related equipment is assigned to one of three different categories, according to location in the plant and anticipated normal, accident and post-accident behavior. Qualification tests differ for each category and procedures range in scope from the standard seismic test to the highly stringent VISA program, which specifies a predetermined sequence of aging, radiation, seismic and simulated accident testing. A network of official French test facilities wasmore » developed specifically to meet RCC-E requirements.« less
Constant-load delayed fracture test of atmospherically corroded high strength steels
NASA Astrophysics Data System (ADS)
Akiyama, Eiji; Matsukado, Katsuhiro; Li, Songjie; Tsuzaki, Kaneaki
2011-07-01
Constant load tests of circumferentially notched round bar specimens of high strength steels after cyclic corrosion test and outdoor exposure have been performed to demonstrate that delayed fracture occurs when the hydrogen content from the environment, H E, exceeds the critical hydrogen content for delayed fracture, H C. During the constant load tests the humidity around the specimen was increased in stepwise manner to increase hydrogen entry. After fracture the specimen was kept at the humidity long enough to homogenize hydrogen in the specimen and to obtain more quantitative hydrogen content by thermal desorption analysis. H E of the fractured specimens was higher than H C, and H E of the specimens not fractured was lower than H C. This result confirms that the balance between H C and H E determines the occurrence of delayed fracture and that hydrogen-content-based evaluation of susceptibility to delayed fracture is reasonable. To certify the increase of H E with increase in humidity, electrochemical hydrogen permeation test was carried out. The hydrogen permeation current density was increased especially at 98%RH. Enhancement of hydrogen entry with increase in CCT number was also shown by the test.
Tests for sensitisation in occupational medicine practice--the soy bean example.
Roodt, L; Rees, D
1995-06-01
To determine the prevalence of sensitisation to soy bean measured by specific IgE and skin prick tests (SPTs) and to examine the association between evidence of sensitisation to soy bean allergens and symptoms of allergic disease. Cross-sectional study. Questionnaire survey. A venous blood sample was taken for specific IgE testing, and SPTs for common allergens and soy bean dust were performed. Soy bean mill. A volunteer sample of 22 workers exposed to soy bean dust; the first 20 non-exposed workers presenting to the National Centre for Occupational Health clinic formed the control group. Immunological tests for sensitisation and symptoms of respiratory and allergic disease. Eight of the exposed workers had positive skin reactions to either full-fat or defatted soy bean. None of the controls was SPT-positive. Eight of the exposed workers had increased levels of soy-specific IgE of whom only 4 were SPT-positive and had an increased level of soy-specific IgE. One of the control workers had an increased level of soy-specific IgE. Workers with an increased specific IgE or SPT positive to soy bean did not have more symptoms than workers with negative tests. However, work-related breathlessness was significantly higher in the exposed group (P < 0.05). The data suggest that the immunological tests for sensitisation were not useful in identifying workers with soy bean-related disease but that tests for sensitisation were linked to exposure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This report is the first in a series of studies on accelerated stress testing (AST) of drivers used for SSL luminaires, such as downlights, troffers, and streetlights. A representative group of two-stage commercial driver products was exposed to an AST environment consisting of 75°C and 75% relative humidity (7575). These drivers were a mix of single-channel drivers (i.e., a single output current for one LED primary) and multichannel drivers (i.e., separate output currents for multiple LED primaries). This AST environment was chosen because previous testing on downlights with integrated drivers demonstrated that 38% of the sample population failed in lessmore » than 2,500 hours of testing using this method. In addition to AST test results, the performance of an SSL downlight product incorporating an integrated, multichannel driver during extended room temperature operational life (RTOL) testing is also reported. A battery of measurements was used to evaluate these products during accelerated testing, including full electrical characterization (i.e., power consumption, PF, total harmonic distortion [THD], and inrush current) and photometric characterization of external LED loads attached to the drivers (i.e., flicker performance and lumen maintenance).« less
Feasibility study and sensory test of turmeric tamarind traditional drink with various processing
NASA Astrophysics Data System (ADS)
Rudyatmi, E.; Bintari, S. H.; Iswari, R. S.
2018-03-01
Turmeric tamarind traditional drink as anti-oxidant, good for health, and has a potency to developed. The objectives of this study are to determine the feasibility and the favorite level of consumer towards two turmerics tamarind traditional drink which processed differently. Feasibility depended on sensory test and microbe's contamination according to a quality standard of BPOM and complemented with an anti-bacterial test. The anti-bacterial test is determined by a diameter of inhibition zone towards E coli and B subtilist. Consumer’s favorites level is determined by organoleptic test to 40 testers. Sensory test results to form, odor, taste, and color are normal. TPC first traditional drink 6,9 x 102 col/gr and TKK ≤1,0x10 col/gr, TPC second traditional drink 2,0 x 101 col/gr and TKK ≤1,0x10 col/gr; all tests toward E coli, Salmonella SP, Staphylococcus aureus, Pseudomonas aeruginosa, shigella sp negative/gr; inhibiting capabilities towards B.subtilis and E coli of first traditional drink > second traditional drink. Inhibiting capabilities towards B.subtilis > E coli. All parameters comply with BPOM standard. Most of the tester love the first method turmeric tamarind traditional drink.
Testing Methods for Integrated Circuit Chips.
1986-03-27
DWf <I IAV ~IMi MORY OUT LOGIC~~ IPOGRAM ASYC S’E4i E...* 16o, CO% T ROL CO%TROL 32 Figure 2 . 14 VLSI Tester Block Diagram. registers, memory and test...neral-pIurpos’ processor wi th standard bus- inte-rfaco se-rves as,- th- test control Ii’r and ( 2 ) a c-ustom VLSI test Controller inti-rfacing direc(_t1...Engineering 2 WTWTY ABSTRACT Provision for the functional testing of fabricated VLSI chips frequently involves as much design effort as the orig- _ inal
2011 Chevrolet Volt VIN 0815 Plug-In Hybrid Electric Vehicle Battery Test Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyler Gray; Matthew Shirk; Jeffrey Wishart
2013-07-01
The U.S. Department of Energy (DOE) Advanced Vehicle Testing Activity (AVTA) program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on plug-in hybrid electric vehicles (PHEVs), including testing the PHEV batteries when both the vehicles and batteries are new and at the conclusion of 12,000 miles of on-road fleet testing. This report documents battery testing performed for the 2011 Chevrolet Volt PHEV (VIN 1G1RD6E48BU100815). The battery testing was performed by the Electric Transportation Engineering Corporation (eTec) dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on themore » AVTA for the Vehicle Technologies Program of the DOE.« less
Santos, Sandra; Viana, Fernanda Leopoldina; Ribeiro, Iolanda; Prieto, Gerardo; Brandão, Sara; Cadime, Irene
2015-03-03
This investigation aimed to develop and collect psychometric data for two tests assessing listening comprehension of Portuguese students in primary school: the Test of Listening Comprehension of Narrative Texts (TLC-n) and the Test of Listening Comprehension of Expository Texts (TLC-e). Two studies were conducted. The purpose of study 1 was to construct four test forms for each of the two tests to assess first, second, third and fourth grade students of the primary school. The TLC-n was administered to 1042 students, and the TLC-e was administered to 848 students. The purpose of study 2 was to test the psychometric properties of new items for the TLC-n form for fourth graders, given that the results in study 1 indicated a severe lack of difficult items. The participants were 260 fourth graders. The data were analysed using the Rasch model. Thirty items were selected for each test form. The results provided support for the model assumptions: Unidimensionality and local independence of the items. The reliability coefficients were higher than .70 for all test forms. The TLC-n and the TLC-e present good psychometric properties and represent an important contribution to the learning disabilities assessment field.
2003-05-05
As easy to read as a home pregnancy test, three Quantifiable Lateral Flow Assay (QLFA) strips used to test water for E. coli show different results. The brightly glowing control line on the far right of each strip indicates that all three tests ran successfully. But the glowing test line on the middle left and bottom strips reveal their samples were contaminated with E. coli bacteria at two different concentrations. The color intensity correlates with concentration of contamination.
Microcircuit Device Reliability Digital Detailed Data
1976-01-01
TYPE s No. FUNCTION A LASS PINS TEMP. TYPE CLASS LEVEL I eFAILED 8 NO. CHIP TEST APPL. TEST PAR1 t T AGATES PROTECT. DATE E:V. D TYPE HOURST :708 FLIP...LEVEL # EFAILED s a NO. t CHIP i TEST 3 APPL. a TEST I PAR! 3 a GATES s PROTECT. a DATE 3 ENV. t TYPE I 3 -OUHb s 354H0( 3 GATE C-I CDIP 14 150C :11.A
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rizzo, Davinia; Blackburn, Mark
Complex systems are comprised of technical, social, political and environmental factors as well as the programmatic factors of cost, schedule and risk. Testing these systems for enhanced security requires expert knowledge in many different fields. It is important to test these systems to ensure effectiveness, but testing is limited to due cost, schedule, safety, feasibility and a myriad of other reasons. Without an effective decision framework for Test and Evaluation (T&E) planning that can take into consideration technical as well as programmatic factors and leverage expert knowledge, security in complex systems may not be assessed effectively. Therefore, this paper coversmore » the identification of the current T&E planning problem and an approach to include the full variety of factors and leverage expert knowledge in T&E planning through the use of Bayesian Networks (BN).« less
Navy Ford (CVN-78) Class Aircraft Carrier Program: Background and Issues for Congress
2013-10-22
states: The CVN 78 is experiencing cost growth due to “first of class” material availability (i.e., valves, actuators ), construction labor...assessment during IOT &E [initial operational test and evaluation]. • The current TEMP [test and evaluation master plan] does not adequately address...developmental testing significantly raises the likelihood of the discovery of platform-level problems during IOT &E. • The Navy plans to deliver CVN-78 in
Used Solvent Testing and Reclamation. Volume 2. Vapor Degreasing and Precision Cleaning Solvents
1988-12-01
of 5 to 500 ppm in halogenated solvents using Karl - Fischer reagent. Arbitrary criteria to identify a spent solvent have evolved in various industries... methods of managing waste solvent. Some DOD installations are reclaiming used solvents rather than discarding them. Reclamation is feasible because the...most E E CT E reliable methods for testing solvent quality. Further testing isnecessary for chlorinated solvents to determine the inhibitor con- FEB 24
Findeisen, P; Zahn, I; Fiedler, G M; Leichtle, A B; Wang, S; Soria, G; Johnson, P; Henzell, J; Hegel, J K; Bendavid, C; Collet, N; McGovern, M; Klopprogge, K
2018-06-04
The new immunochemistry cobas e 801 module (Roche Diagnostics) was developed to meet increasing demands on routine laboratories to further improve testing efficiency, while maintaining high quality and reliable data. During a non-interventional multicenter evaluation study, the overall performance, functionality and reliability of the new module was investigated under routine-like conditions. It was tested as a dedicated immunochemistry system at four sites and as a consolidator combined with clinical chemistry at three sites. We report on testing efficiency and analytical performance of the new module. Evaluation of sample workloads with site-specific routine request patterns demonstrated increased speed and almost doubled throughput (maximal 300 tests per h), thus revealing that one cobas e 801 module can replace two cobas e 602 modules while saving up to 44% floor space. Result stability was demonstrated by QC analysis per assay throughout the study. Precision testing over 21 days yielded excellent results within and between labs, and, method comparison performed versus the cobas e 602 module routine results showed high consistency of results for all assays under study. In a practicability assessment related to performance and handling, 99% of graded features met (44%) or even exceeded (55%) laboratory expectations, with enhanced reagent management and loading during operation being highlighted. By nearly doubling immunochemistry testing efficiency on the same footprint as a cobas e 602 module, the new module has a great potential to further consolidate and enhance laboratory testing while maintaining high quality analytical performance with Roche platforms. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Peng, Z; Xu, W W; Sham, Y; Lam, H; Sun, D; Cheng, L; Rasic, N F; Guan, Q; James, A A; Simons, F E R
2016-05-01
Allergic reactions to mosquito bites are an increasing clinical concern. Due to the lack of availability of mosquito salivary allergens, they are underdiagnosed. Here, we reported a newly cloned mosquito Aedes (Ae.) aegypti salivary allergen. A cDNA encoding a 30-kDa Ae. aegypti salivary protein, designated Aed a 3, was isolated from an expression library. The full-length cDNA was cloned into a baculovirus expression vector, and recombinant Aed a 3 (rAed a 3) was expressed, purified, and characterized. Skin prick tests with purified rAed a 3 and Ae. aegypti bite tests were performed in 43 volunteers. Serum rAed a 3-specific IgE levels were measured in 28 volunteers. The primary nucleotide sequence, deduced amino acid sequence, and IgE-binding sites of Aed a 3 were identified. rAed a 3-selected antibodies recognized a 30-kDa Ae. aegypti saliva protein. rAed a 3 bound IgE in mosquito-allergic volunteers and the binding could be inhibited by the addition of natural mosquito extract dose dependently. Immediate skin test reactions to rAed a 3 correlated significantly with mosquito bite-induced reactions. Of the bite test-positive volunteers, 32% had a positive rAed a 3 skin test and 46% had specific IgE. No bite test-negative volunteers reacted to rAed a 3 in either the skin tests or the IgE assays, confirming the specificity of the assay. Aed a 3 that corresponds to the Aegyptin protein is a major mosquito salivary allergen. Its recombinant form has biological activity and is suitable for use in skin tests and specific IgE assays in mosquito-allergic individuals. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
McNelis, Mark E.; Hughes, William O.; Larko, Jeffrey M.; Bittinger, Samantha A.; Le-Plenier, Cyprien; Fogt, Vincent A.; Ngan, Ivan; Thirkettle, Anthony C.; Skinner, Mitch; Larkin, Paul
2017-01-01
The NASA Orion Multi-Purpose Crew Vehicle (MPCV), comprised of the Service Module, the Crew Module, and the Launch Abort System, is the next generation human spacecraft designed and built for deep space exploration. Orion will launch on NASAs new heavy-lift rocket, the Space Launch System. The European Space Agency (ESA) is responsible for providing the propulsion sub-assembly of the Service Module to NASA, called the European Service Module (ESM). The ESM is being designed and built by Airbus Safran Launchers for ESA. Traditionally, NASA has utilized reverberant acoustic testing for qualification of spaceflight hardware. The ESM Structural Test Article (E-STA) was tested at the NASA Plum Brook Stations (PBS) Reverberant Acoustic Test Facility in April-May 2016. However, Orion is evaluating an alternative acoustic test method, using direct field acoustic excitation, for the MPCVs Service Module and Crew Module. Lockheed Martin is responsible for the Orion proof-of-concept direct field acoustic test program. The E-STA was exposed to direct field acoustic testing at NASA PBS in February 2017. This paper compares the dynamic response of the E-STA structure and its components to both the reverberant and direct field acoustic test excitations. Advantages and disadvantages of direct field acoustic test excitation method are discussed.
Sato, Sakura; Yanagida, Noriyuki; Ebisawa, Motohiro
2018-06-01
To assess the recent studies that focus on specific immunoglobulin E (sIgE) testing and basophil activation test (BAT) for diagnosing IgE-mediated food allergies. The sIgE to allergen extract or component can predict reactivity to food. The cutoff value based on the positive predictive value (PPV) of sIgE can be considered whenever deciding whether oral food challenge (OFC) is required to diagnose hen's egg, cow's milk, wheat, peanut, and cashew nut allergy. However, PPV varies depending on the patients' background, OFC methodology, challenge foods, and assay methodology. Component-resolved diagnostics (CRD) has been used for food allergy diagnosis. Ovomucoid and omega-5 gliadin are good diagnostic markers for heated egg and wheat allergy. More recently, CRD of peanut, tree nuts, and seed have been investigated. Ara h 2 showed the best diagnostic accuracy for peanut allergy; other storage proteins, such as Jug r 1 for walnut, Ana o 3 for cashew nut, Ses i 1 for sesame, and Fag e 3 for buckwheat, are also better markers than allergen extracts. Some studies suggested that BAT has superior specificity than skin prick test and sIgE testing. The sIgE testing and BAT can improve diagnostic accuracy. CRD provides additional information that can help determine whether OFCs should be performed to diagnose food allergy.
Yang, Li; Zhu, Yuanhang; Bai, Yang; Zhang, Xiaoan; Ren, Chenchen
2017-01-01
The aim is to evaluate the clinical application value and correlation with cervical lesions' progression of human papillomavirus (HPV) E6/E7 mRNA test in women with atypical squamous cells of undetermined significance (ASCUS/borderline) or low-grade squamous intraepithelial lesions (LSILs/mild dyskaryosis) cytological abnormalities. A meta-analysis was conduct by searching China National Knowledge Infrastructure (1979-2016), Wanfang Date (1998-2016), VIP (1989-2016), PubMed (1950-2016), Web of Science (1950-2016) and Elsevier Science Direct (1998-2016), for studies on effect of HPV E6/E7 mRNA detection in women with ASCUS/LSIL/dyskaryosis. Study selection and appraisal were conducted independently by three authors, according to inclusive and exclusive criteria. Then, a meta-analysis was performed using the RevMan4.2 software. The subgroups analysis was conducted according to women's initial HPV DNA test results. Six articles with a total of 1024 subjects were included in the study. It was concluded that a positive HPV E6/E7 mRNA tested result have a higher risk of progressing to CIN2+ in future 2 years than a negative result. The pooled relative risk (RR) is 3.08, (95% confidence interval [CI] = 1.57-6.07, P < 0.05). The same situation was also observed in the subgroup of HPV DNA tested positive group and HPV DNA tested unlimited group. The pooled RR value of the two subgroups was, respectively, 1.98, (95% CI = 1.19-1.19, P < 0.05) and 7.58, (95% CI = 3.64-3.64, P < 0.05). A positive HPV E6/E7 mRNA testing result suggested the women with ASCUS, or LSIL Pap smear was in a truly dangerous position, which is an adverse prognostic factor. It suggested that cervical lesions stay in a progressing status and these women should be referred for colposcopy and strengthen follow-up promptly. Whereas, women with a negative HPV E6/E7 mRNA testing result can increase follow-up interval, by comprehensively considering their situation, thus, avoiding unnecessary colposcopy and reducing the rate of colposcopy and biopsy.
Phototoxicity assessment of drugs and cosmetic products using E. coli.
Verma, K; Agrawal, N; Misra, R B; Farooq, M; Hans, R K
2008-02-01
A gram negative bacteria Escherichia coli (Dh5alpha strain) was developed as an alternate test system of phototoxicity. Eight drugs (antibiotics) and cosmetic products (eight face creams) were examined for their phototoxicity using this test system. Five known phototoxic compounds were used to validate the test system. UVA-radiation induced phototoxicity of these compounds was tested by agar gel diffusion assay. Decrease in colony forming units (CFU) was taken as an end point of phototoxicity. The phototoxic compounds and antibiotics produced significant reduction in CFU (p<0.001) at 80 microg/ml concentrations under exposure to UVA-radiation (5.4-10.8 J/cm(2)). One face cream was found phototoxic and produced significant decrease in CFU of E. coli at 1.0mg/ml concentration under UVA exposure (10.8 J/cm(2)). The minimum effective concentration of tetracycline and dose of UVA-radiation were also determined by observing growth inhibition of E. coli through disc diffusion assay. The observations suggested that E. coli can be used as an alternative test system for phototoxicity evaluation of chemicals. A battery of test systems is required to conclude the toxic/phototoxic potential of a chemical agent. In view of the speed, easiness, sensitivity and low cost, E. coli is introduced as one of the alternate test system for phototoxicity studies in safety evaluation of various chemical ingredients or formulations used in cosmetics and drugs.
Our experience with atopy patch tests with aeroallergens.
Celakovská, Jarmila; Ettlerová, Kvetuse; Ettler, Karel; Vanecková, Jaroslava
2013-01-01
Aim of our study was to evaluate the importance of atopy patch testing with aeroallergens as a diagnostic method in patients suffering from atopic dermatitis. The complet dermatological and allergological examinations were performed in 29 patients; 10 men, 19 women with the average age of 27.8 years, min. 17, max. 57 years; with the median SCORAD 24.2 points, s.d. 13.3 points. Wormwood, grass, dog dander, cat dander, dermatophagoides pharinae, dermatophagoides pteronyssinus and birch pollen were examined in diagnostic procedures. Skin prick tests, specific IgE were examined; the atopy patch tests were performed with aeroallergens for skin prick tests in concentration 1 x skin prick tests. Specific IgE and skin prick tests to one or more tested aeroallergens were positive altogether in 27 patients; atopy patch tests were positive only in one of these patients. For atopy patch testing with aeroallergens the concentration of 1 x skin prick tests is low to confirme the eczematic reaction in patients suffering from allergy to inhallant allergens.
Computerized Classification Testing with the Rasch Model
ERIC Educational Resources Information Center
Eggen, Theo J. H. M.
2011-01-01
If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…
Groundwater Remediation and Alternate Energy at White Sands Test Facility
NASA Technical Reports Server (NTRS)
Fischer, Holger
2008-01-01
White Sands Test Facility Core Capabilities: a) Remote Hazardous Testing of Reactive, Explosive, and Toxic Materials and Fluids; b) Hypergolic Fluids Materials and Systems Testing; c) Oxygen Materials and System Testing; d) Hypervelocity Impact Testing; e)Flight Hardware Processing; and e) Propulsion Testing. There is no impact to any drinking water well. Includes public wells and the NASA supply well. There is no public exposure. Groundwater is several hundred feet below ground. No air or surface water exposure. Plume is moving very slowly to the west. Plume Front Treatment system will stop this westward movement. NASA performs on-going monitoring. More than 200 wells and zones are routinely sampled. Approx. 850 samples are obtained monthly and analyzed for over 300 different hazardous chemicals.
12 CFR 563e.24 - Service test.
Code of Federal Regulations, 2010 CFR
2010-01-01
... of alternative systems for delivering retail banking services (e.g., ATMs, ATMs not owned or operated... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Service test. 563e.24 Section 563e.24 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY COMMUNITY REINVESTMENT Standards for...
Factors to Consider When Implementing Automated Software Testing
2016-11-10
programming, e.g., Java or Visual Basic. Subject Matter Experts (SME) with firm grasp of application being automated. 2. Additional costs for setup (e.g...Abilities (KSA) required (e.g., Test and Evaluation). 2. Analyze programming skills needed (e.g., Java , C, C++, Visual Basic). 3. Compose team – testers
The Relationship between Tests of Creativity and Perception.
ERIC Educational Resources Information Center
Lindauer, Martin S.
The relationship between creativity and perception was examined in two studies that correlated a combined total of 11 tests of perception (e.g., figure-ground and physiognomy) and creativity (e.g., remote associates and figure preferences). Four of the tests dealt with perception, five with creativity, and two with both. Since several of the tests…
6. Credit WCT. Photographic copy of photograph, Advanced Solid Rocket ...
6. Credit WCT. Photographic copy of photograph, Advanced Solid Rocket Motor (ASRM) test in progress at Test Stand 'E.' It was a JPL/Marshall Space Flight Center project. (JPL negative no. 344-4816 19 February 1982) - Jet Propulsion Laboratory Edwards Facility, Test Stand E, Edwards Air Force Base, Boron, Kern County, CA
14 CFR 415.129 - Flight safety system test data.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., acceptance, age surveillance, and preflight testing of a flight safety system and its subsystems and..., subsystem, and component testing requirements of part 417 of this chapter and appendix E to part 417 of this... demonstrate similarity by performing the analysis required by appendix E of part 417 of this chapter. The...
14 CFR 415.129 - Flight safety system test data.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., acceptance, age surveillance, and preflight testing of a flight safety system and its subsystems and..., subsystem, and component testing requirements of part 417 of this chapter and appendix E to part 417 of this... demonstrate similarity by performing the analysis required by appendix E of part 417 of this chapter. The...
14 CFR 415.129 - Flight safety system test data.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., acceptance, age surveillance, and preflight testing of a flight safety system and its subsystems and..., subsystem, and component testing requirements of part 417 of this chapter and appendix E to part 417 of this... demonstrate similarity by performing the analysis required by appendix E of part 417 of this chapter. The...
14 CFR 415.129 - Flight safety system test data.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., acceptance, age surveillance, and preflight testing of a flight safety system and its subsystems and..., subsystem, and component testing requirements of part 417 of this chapter and appendix E to part 417 of this... demonstrate similarity by performing the analysis required by appendix E of part 417 of this chapter. The...
14 CFR 415.129 - Flight safety system test data.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., acceptance, age surveillance, and preflight testing of a flight safety system and its subsystems and..., subsystem, and component testing requirements of part 417 of this chapter and appendix E to part 417 of this... demonstrate similarity by performing the analysis required by appendix E of part 417 of this chapter. The...
40 CFR 63.428 - Reporting and recordkeeping.
Code of Federal Regulations, 2010 CFR
2010-07-01
...; pressure or vacuum change, mm of water; time period of test; number of leaks found with instrument; and... facility as follows: (1) Annual certification testing performed under § 63.425(e) and railcar bubble leak...)); Annual Certification Test—Internal Vapor Valve (§ 63.425(e)(2)); Leak Detection Test (§ 63.425(f...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-24
... Impact Statement for Outdoor Research, Development, Test and Evaluation Activities, Naval Surface Warfare..., development, test and evaluation (RDT&E) activities within the Potomac River Test Range (PRTR) complex... current, baseline RDT&E mission requirements for activities that have the potential to affect human health...
Diagnostic Testing at UK Universities: An E-Mail Survey
ERIC Educational Resources Information Center
Gillard, Jonathan; Levi, Margaret; Wilson, Robert
2010-01-01
In July 2009, an e-mail survey was sent to various UK universities to gain information regarding current practices concerning mathematics diagnostic testing, and to provide an update from the review "Diagnostic Testing for Mathematics" published by the LTSN MathsTEAM Project in 2003. A total of 38 university departments were contacted…
Antioxidative properties of the essential oil from Pinus mugo.
Grassmann, Johanna; Hippeli, Susanne; Vollmann, Renate; Elstner, Erich F
2003-12-17
The essential oil from Pinus mugo (PMEO) was tested on its antioxidative capacity. For this purpose, several biochemical test systems were chosen (e.g., the Fenton System, the xanthine oxidase assay, or the copper-induced oxidation of low-density lipoprotein (LDL)). The results show that there is moderate or weak antioxidative activity when tested in aqueous environments, like in the Fenton system, xanthine oxidase induced superoxide radical formation, or in the HOCl driven fragmentation of 1-aminocyclopropane-1-carboxylic acid (ACC). In contrast, when tested in more lipophilic environments (e.g., the ACC-cleavage by activated neutrophils in whole blood) the PMEO exhibits good antioxidative activity. PMEO does also show good antioxidative capacity in another lipophilic test system (i.e., the copper induced oxidation of LDL). Some components of PMEO (i.e., Delta(3)-carene, camphene, alpha-pinene, (+)-limonene and terpinolene) were also tested. As the PMEO, they showed weak or no antioxidant activity in aqueous environments, but some of them were effective antioxidants regarding ACC-cleavage by activated neutrophils in whole blood or copper-induced LDL-oxidation. Terpinolene, a minor component of PMEO, exhibited remarkable protection against LDL-oxidation.
Hempel, Dorothea; Sinnathurai, Sivajini; Haunhorst, Stephanie; Seibel, Armin; Michels, Guido; Heringer, Frank; Recker, Florian; Breitkreutz, Raoul
2016-08-01
Theoretical knowledge, visual perception, and sensorimotor skills are key elements in ultrasound education. Classroom-based presentations are used routinely to teach theoretical knowledge, whereas visual perception and sensorimotor skills typically require hands-on training (HT). We aimed to compare the effect of classroom-based lectures versus a case-based e-learning (based on clinical cases only) on the hands-on performance of trainees during an emergency ultrasound course. This is a randomized, controlled, parallel-group study. Sixty-two medical students were randomized into two groups [group 1 (G1) and group 2 (G2)]. G1 (n=29) was subjected to a precourse e-learning, based on 14 short screencasts (each 5 min), an on-site discussion (60 min), and a standardized HT session on the day of the course. G2 (n=31) received classroom-based presentations on the day of the course before an identical HT session. Both groups completed a multiple-choice (MC) pretest (test A), a practical postcourse test (objective structured clinical exam), and MC tests directly after the HT (test B) and 1 day after the course (test C). The Mann-Whitney U-test was used for statistical analysis. G1 performed markedly better in test A (median 84.2, 25%; 75% percentile: 68.5; 92.2) compared with G2 (65.8; 53.8; 80.4), who had not participated in case-based e-learning (P=0.0009). No differences were found in the objective structured clinical exam, test B, and test C. e-learning exclusively based on clinical cases is an effective method of education in preparation for HT sessions and can reduce attendance time in ultrasound courses.
Wainstein, Brynn Kevin; Yee, Anthony; Jelley, Donna; Ziegler, Mary; Ziegler, John B
2007-05-01
Previous studies have suggested various diagnostic cut-offs of allergy tests for the diagnosis of clinical peanut allergy in children. There are few data relating to the use of combinations of these tests in children. We aimed to determine the validity of previously reported diagnostic cut-off levels of peanut allergen skin tests and peanut specific-immunoglobulin (Ig) E, as well as the usefulness of combinations of these, for predicting clinical peanut allergy in our Allergy Clinic. Children attending the Allergy Clinic with a positive peanut skin prick test (SPT; n = 84) were included in the study. Immediate skin application food tests (I-SAFT) using 1 g of peanut butter (positive if any wheals were detected at 15 min), peanut specific-IgE levels and open-label peanut food challenges were performed. Fifty-two of 85 peanut challenges were positive. Skin prick test specificity was 67% at >or=8 mm and 100% at >or=15 mm. The I-SAFT was 82% specific. A peanut specific-IgE level of 0.37 kU/l was 98% sensitive but 33% specific. A level of 10 kU/l was 100% specific. Combinations of a SPT of >or=8 mm with a positive I-SAFT and a peanut specific-IgE >or=0.37 kU/l were 88% specific with a sensitivity of 38%. Using challenge outcomes as the standard, available in vitro and in vivo diagnostic tests for peanut allergy have poor sensitivity and specificity and combining them does not significantly improve their clinical usefulness. Previously described diagnostic cut-off levels do not have general applicability. Allergy practitioners may need to interpret results of allergy tests in the context of their own practices.
Effect of non-normality on test statistics for one-way independent groups designs.
Cribbie, Robert A; Fiksenbaum, Lisa; Keselman, H J; Wilcox, Rand R
2012-02-01
The data obtained from one-way independent groups designs is typically non-normal in form and rarely equally variable across treatment populations (i.e., population variances are heterogeneous). Consequently, the classical test statistic that is used to assess statistical significance (i.e., the analysis of variance F test) typically provides invalid results (e.g., too many Type I errors, reduced power). For this reason, there has been considerable interest in finding a test statistic that is appropriate under conditions of non-normality and variance heterogeneity. Previously recommended procedures for analysing such data include the James test, the Welch test applied either to the usual least squares estimators of central tendency and variability, or the Welch test with robust estimators (i.e., trimmed means and Winsorized variances). A new statistic proposed by Krishnamoorthy, Lu, and Mathew, intended to deal with heterogeneous variances, though not non-normality, uses a parametric bootstrap procedure. In their investigation of the parametric bootstrap test, the authors examined its operating characteristics under limited conditions and did not compare it to the Welch test based on robust estimators. Thus, we investigated how the parametric bootstrap procedure and a modified parametric bootstrap procedure based on trimmed means perform relative to previously recommended procedures when data are non-normal and heterogeneous. The results indicated that the tests based on trimmed means offer the best Type I error control and power when variances are unequal and at least some of the distribution shapes are non-normal. © 2011 The British Psychological Society.
Cost-effectiveness of various methods of diagnosing hypersensitivity to Alternaria.
Escudero, A I; Sánchez-Guerrero, I M; Mora, A M; Soriano, V; López, J D; García, F J; Negro, J M; Hernández, J; Pagán, J A
1993-01-01
This study was undertaken for two reasons: 1) It is more difficult to diagnose hypersensitivity to molds than to other allergens, so an evaluation of diagnostic tests was needed. 2) Alternaria is the principal cause of mold sensitization in our area. Sixty-six patients (20 +/- 4 years) were selected and divided into two groups. Group A was made up of patients with rhinitis and/or asthma due to Alternaria sensitization. Group B consisted of patients sensitized to other allergens and patients with nonrespiratory allergic disorders. Skin tests (prick and intradermal), challenge tests (conjunctival, nasal, and bronchial), and specific IgE determination were performed for all patients. A biologically standardized extract of Alternaria tenuis (Alergia e Inmunología Abelló, S. A., Madrid, Spain) obtained from a single batch was used for all tests. Our diagnostic criterion was a clinical history of rhinitis or asthma that coincided with the results of nasal/bronchial challenge. The diagnostic value of the other tests was compared to this criterion. In the group of rhinitic patients, skin tests and conjunctival challenge were more sensitive than specific IgE determination. In asthmatic patients, the most sensitive techniques were nasal and conjunctival challenges, followed by prick and intradermal skin tests, and, lastly, serum specific IgE determination. When rhinitis and asthma were considered jointly, the most sensitive test was conjunctival challenge, followed by skin-prick and intradermal tests. All tests had the same specificity, regardless of disorder. Nasal challenge was positive in all patients. Skin tests are easy to perform, cheap, non-traumatic for the patient, and sufficiently specific and sensitive for the diagnosis of Alternaria hypersensitivity.(ABSTRACT TRUNCATED AT 250 WORDS)
A combination test for detection of gene-environment interaction in cohort studies.
Coombes, Brandon; Basu, Saonli; McGue, Matt
2017-07-01
Identifying gene-environment (G-E) interactions can contribute to a better understanding of disease etiology, which may help researchers develop disease prevention strategies and interventions. One big criticism of studying G-E interaction is the lack of power due to sample size. Studies often restrict the interaction search to the top few hundred hits from a genome-wide association study or focus on potential candidate genes. In this paper, we test interactions between a candidate gene and an environmental factor to improve power by analyzing multiple variants within a gene. We extend recently developed score statistic based genetic association testing approaches to the G-E interaction testing problem. We also propose tests for interaction using gene-based summary measures that pool variants together. Although it has recently been shown that these summary measures can be biased and may lead to inflated type I error, we show that under several realistic scenarios, we can still provide valid tests of interaction. These tests use significantly less degrees of freedom and thus can have much higher power to detect interaction. Additionally, we demonstrate that the iSeq-aSum-min test, which combines a gene-based summary measure test, iSeq-aSum-G, and an interaction-based summary measure test, iSeq-aSum-I, provides a powerful alternative to test G-E interaction. We demonstrate the performance of these approaches using simulation studies and illustrate their performance to study interaction between the SNPs in several candidate genes and family climate environment on alcohol consumption using the Minnesota Center for Twin and Family Research dataset. © 2017 WILEY PERIODICALS, INC.
Routine use of point-of-care tests: usefulness and application in clinical microbiology.
Clerc, O; Greub, G
2010-08-01
Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.
Genotoxicity studies in groundwater, surface waters, and contaminated soil.
Verschaeve, Luc
2002-05-08
It is at present considered important to include biological tests in measuring programmes of environmental samples to supplement the chemical and physical parameters that are currently used. A battery of tests is therefore necessary, also within a given "endpoint" (e.g., genotoxicity), because one single test will not give all the answers to our questions. As it is not possible to include all available tests in routine screening programmes, a selection of tests should be made. According to comparative investigations, the bacterial Ames test remains very important. When no preconcentration step is involved, other bacterial tests (e.g., the umu-C and VITOTOX tests) may be recommended. The comet assay may be used in Daphnia or human white blood cells. Further validations, comparisons, mechanistic investigations, etc. remain necessary as differences are often found between the tests that are not solely explained by differences in genetic endpoint and that therefore should further be investigated and understood.
Age-related differences in guessing on free and forced recall tests.
Huff, Mark J; Meade, Michelle L; Hutchison, Keith A
2011-05-01
This study examined possible age-related differences in recall, guessing, and metacognition on free recall tests and forced recall tests. Participants studied categorised and unrelated word lists and were asked to recall the items under one of the following test conditions: standard free recall, free recall with a penalty for guessing, free recall with no penalty for guessing, or forced recall. The results demonstrated interesting age differences regarding the impact of liberal test instructions (i.e., forced recall and no penalty) relative to more conservative test instructions (i.e., standard free recall and penalty) on memory performance. Specifically, once guessing was controlled, younger adults' recall of categorised lists varied in accordance with test instructions while older adults' recall of categorised lists did not differ between conservative and liberal test instructions, presumably because older adults approach standard free recall tests of categorised lists with a greater propensity towards guessing than young adults.
Hot-Fire Testing of a 1N AF-M315E Thruster
NASA Technical Reports Server (NTRS)
Burnside, Christopher G.; Pedersen, Kevin; Pierce, Charles W.
2015-01-01
This hot-fire test continues NASA investigation of green propellant technologies for future missions. To show the potential for green propellants to replace some hydrazine systems in future spacecraft, NASA Marshall Space Flight Center (MSFC) is continuing to embark on hot-fire test campaigns with various green propellant blends. NASA completed a hot-fire test of a 1N AF-M315E monopropellant thruster at the Marshall Space Flight Center in the small altitude test stand located in building 4205. The thruster is a ground test article used for basic performance determination and catalyst studies. The purpose of the hot-fire testing was for performance determination of a 1N size thruster and form a baseline from which to study catalyst performance and life with follow-on testing to be conducted at a later date. The thruster performed as expected. The result of the hot-fire testing are presented in this paper and presentation.
4. Credit BG. View looking northwest at Control and Recording ...
4. Credit BG. View looking northwest at Control and Recording Center 4221/E-22, as seen from Test Stand 'C' tower. The Test Stand 'C' workshop 4213/E-14 appears at lower left of the image. To the south of 4221/E-22 lies Blower House No. 2, Building 4226/E-27, used for ventilating the tunnel system which connected 4221/E-22 to all test stands. At the southeast corner of 4221/E-22 is the Booster Pumping Station, Building 4227/E-28. To the northwest of 4221/E-22 is a Water Storage Tank, Building 4289/E-90 which supplies the water and firefighting systems at the JPL Edwards facility. - Jet Propulsion Laboratory Edwards Facility, Control & Recording Center, Edwards Air Force Base, Boron, Kern County, CA
Han, Hock Siew; Kano, Rui; Chen, Charles; Noli, Chiara
2017-02-01
Feline sporotrichosis is common in Malaysia. Thermosensitivity and effects of azole treatment on fungal susceptibility are unknown. To evaluate thermotolerance and antifungal susceptibility of feline Malaysian Sporothrix isolates, compare microdilution (MD) and E-test results, and investigate changes in susceptibility during azole therapy. Sporothrix schenckii sensu stricto was isolated from 44 cats. Thermotolerance was determined via culture at 37°C for 7 days. Susceptibility to itraconazole (ITZ), ketoconazole (KTZ) and terbinafine (TRB) was assessed in 40 isolates by MD; to amphotericin B (AMB), KTZ, ITZ, fluconazole (FLC) and posaconazole (POS) by E-test. Results were statistically compared by Pearson's Product Moment. In eight ketoconazole treated cats, susceptibility testing to itraconazole and ketoconazole was repeated every two months for six months. Thermotolerance was observed in 36 of 44 (82%) isolates. Assuming that isolates growing at antifungal concentrations ≥4 mg/mL were resistant, all were resistant on E-test to FLC and AMB, 11 (28%) to POS, 6 (15%) to ITZ and 1 (3%) to KTZ. On MD, 27 of 40 (68%) were resistant to TRB, 2 (5%) to ITZ and 3 (8%) to KTZ. There was no correlation between E-test and MD results (KTZ r = 0.10, P = 0.54, and ITZ r = 0.11, P = 0.48). MD values for ITZ and KTZ did not exceed 4 mg/L during KTZ therapy. The majority of feline isolates in Malaysia are thermosensitive. Lack of correlation between E-test and MD suggests that the E-test is unreliable to test antifungal susceptibility for Sporothrix spp. compared to MD. KTZ was the antifungal drug with the lowest MIC. Prolonged KTZ administration may not induce changes in antifungal susceptibility. © 2017 ESVD and ACVD.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Permitted Tolerance for Conducting Radiative Tests E Table E-2 to Subpart E of Part 53 Protection of... Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 Pt. 53, Subpt. E, Table E-2 Table E-2 to Subpart E of Part 53—Spectral Energy Distribution and Permitted Tolerance for...
Initial testing of two DEMI (Driesbach Electromotive Inc. ) Model 4E zinc-air rechargeable cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardin, J.E.; Martin, M.E.
1989-10-23
The purpose of this document is to report the results of INEL laboratory testing of two DEMI 4E Aerobic Power Battery Cells (collectively designated Pack 46 in INEL records). The 4E Aerobic Power Battery is a secondary battery developed privately by Driesbach Electromotive Inc. (DEMI). The battery employs zinc as the anode and a bifunctional air cathode. This testing was performed as the first phase of a cooperative agreement between INEL and DEMI leading to the construction and testing of electric vehicle-size cells, to be followed eventually by a battery pack. 3 refs., 3 figs., 5 tabs.
The CD63 basophil activation test in Hymenoptera venom allergy: a prospective study.
Sturm, G J; Böhm, E; Trummer, M; Weiglhofer, I; Heinemann, A; Aberer, W
2004-10-01
The basophil activation test (BAT), which relies on flow cytometric quantitation of the allergen-induced up-regulation of the granule-associated marker CD63 in peripheral blood basophils, has been suggested to be a useful approach in detecting responsiveness to allergens. The purpose of this study was to establish the usefulness of the BAT with regard to the clinical history and current diagnostic tools in Hymenoptera venom allergy using a prospective study design. Fifty-seven consecutive patients allergic to Hymenoptera venom as defined by a systemic reaction after an insect sting, and 30 age- and sex-matched control subjects with a negative history were included. The degree and nature of sensitization was confirmed by skin testing, specific immunoglobulin E (IgE), serum tryptase levels and BAT. In the nonallergic control group only analysis of specific IgE and BAT were performed. Correlation of BAT, skin test and specific IgE, respectively, with the clinical history in the allergic group was termed as sensitivity and in the control group as specificity. Twenty one of 23 (91.3%) bee venom allergic patients and 29 of 34 (85.3%) patients allergic to wasp and hornet venom tested positive in BAT. The overall sensitivity of BAT, specific IgE and skin tests were 87.7, 91.2 and 93.0%, respectively. The overall specificities were 86.7% for BAT and 66.7% for specific IgE. No correlation between the severity of clinical symptoms and the magnitude of basophil activation was observed. The BAT seems to be an appropriate method to identify patients allergic to bee or wasp venom with a comparable sensitivity to standard diagnostic regimens. The higher specificity of BAT as compared with specific IgE makes this test a useful tool in the diagnosis of Hymenoptera venom allergy.
Hydraulic Testing of Silurian and Ordovician Strata at the Bruce Site
NASA Astrophysics Data System (ADS)
Beauheim, R. L.; Avis, J. D.; Chace, D. A.; Roberts, R. M.; Toll, N. J.
2009-05-01
Ontario Power Generation is proposing a Deep Geologic Repository (DGR) for the long-term management of its Low and Intermediate Level Radioactive Waste (L&ILW) within a Paleozoic-age sedimentary sequence beneath the Bruce Site near Tiverton, Ontario, Canada. The concept envisions that the DGR would be excavated at a depth of approximately 680 m within the Ordovician Cobourg Formation, a massive, dense, argillaceous limestone. A key attribute of the Bruce site is the extremely low permeabilities associated with the thick Ordovician carbonate and argillaceous bedrock formations that will host and enclose the DGR. Such rock mass permeabilities are thought sufficiently low to contribute toward or govern a diffusion-dominated transport regime. To support this concept, hydraulic testing was performed in 2008 and 2009 in two deep boreholes at the proposed repository site, DGR-3 and DGR-4. The hydraulic testing was performed using a straddle-packer tool with a 30.74-m test interval. Sequential tests were performed over the entire open lengths of the boreholes from the F Unit of the Silurian Salina Formation into the Ordovician Gull River Formation, a distance of approximately 635 m. The tests consisted primarily of pressure-pulse tests, with a few slug tests performed in several of the higher permeability Silurian units. The tests are analyzed using the nSIGHTS code, which allows the entire pressure history a test interval has experienced since it was penetrated by the drill bit to be included in the test simulation. nSIGHTS also allows the model fit to the test data to be optimized over an n-dimensional parameter space to ensure that the final solution represents a true global minimum rather than simply a local minimum. The test results show that the Ordovician-age strata above the Coboconk Formation (70+ m below the Cobourg) have average horizontal hydraulic conductivities of 1E-13 m/s or less. Coboconk and Gull River hydraulic conductivities are as high as 1E-11 m/s. Hydraulic conductivities of the Silurian-age strata generally range from 1E-13 to 1E-11 m/s, with discrete test values approaching 1E-7 m/s associated with portions of the A2 and A1 Units of the Salina Formation and with the Guelph Formation.
Liver function tests are common tests that are used to see how well the liver is working. Tests include: ... E, Bowne WB, Bluth MH. Evaluation of liver function. In: McPherson RA, Pincus MR, eds. Henry's Clinical ...
Fernández, T D; Torres, M J; Blanca-López, N; Rodríguez-Bada, J L; Gomez, E; Canto, G; Mayorga, C; Blanca, M
2009-02-01
Skin test sensitivity in patients with immediate allergy to penicillins tends to decrease over time, but no information is available concerning in vitro tests. We analysed the negativization rates of two in vitro methods that determine specific immunoglobulin E (IgE) antibodies, the basophil activation test using flow cytometry (BAT) and the radioallergosorbent test (RAST), in immediate allergic reactions to penicillins. Forty-one patients with immediate allergic reactions to amoxicillin were followed up over a 4-year period. BAT and RAST were performed at 6-month intervals. Patients were randomized into groups: Group I, skin tests carried out at regular intervals; Group II, skin tests made only at the beginning of the study. Differences were observed between RAST and BAT (P < 0.01), the latter showing earlier negativization. Considering different haptens, significant differences for the rate of negativization were only found for amoxicillin (P < 0.05). Comparisons between Groups I (n = 10) and II (n = 31) showed a tendency to become negative later in Group I with RAST. Levels of specific IgE antibodies tended to decrease over time in patients with immediate allergic reactions to amoxicillin. Conversion to negative took longer for the RAST assay, although the differences were only detected with the amoxicillin hapten. Skin testing influenced the rate of negativization of the RAST assay, contributing to maintenance of in vitro sensitivity. Because of the loss of sensitivity over time, the determination of specific IgE antibodies to penicillins in patients with immediate allergic reactions must be done as soon as possible after the reaction.
Landman, David; Salamera, Julius; Quale, John
2013-12-01
Carbapenem-resistant Enterobacter species are emerging nosocomial pathogens. As with most multidrug-resistant Gram-negative pathogens, the polymyxins are often the only therapeutic option. In this study involving clinical isolates of E. cloacae and E. aerogenes, susceptibility testing methods with polymyxin B were analyzed. All isolates underwent testing by the broth microdilution (in duplicate) and agar dilution (in duplicate) methods, and select isolates were examined by the Etest method. Selected isolates were also examined for heteroresistance by population analysis profiling. Using a susceptibility breakpoint of ≤2 μg/ml, categorical agreement by all four dilution tests (two broth microdilution and two agar dilution) was achieved in only 76/114 (67%) of E. cloacae isolates (65 susceptible, 11 resistant). Thirty-eight (33%) had either conflicting or uninterpretable results (multiple skip wells, i.e., wells that exhibit no growth although growth does occur at higher concentrations). Of the 11 consistently resistant isolates, five had susceptible MICs as determined by Etest. Heteroresistant subpopulations were detected in eight of eight isolates tested, with greater percentages in isolates with uninterpretable MICs. For E. aerogenes, categorical agreement between the four dilution tests was obtained in 48/56 (86%), with conflicting and/or uninterpretable results in 8/56 (14%). For polymyxin susceptibility testing of Enterobacter species, close attention must be paid to the presence of multiple skip wells, leading to uninterpretable results. Susceptibility also should not be assumed based on the results of a single test. Until the clinical relevance of skip wells is defined, interpretation of polymyxin susceptibility tests for Enterobacter species should be undertaken with extreme caution.
Landman, David; Salamera, Julius
2013-01-01
Carbapenem-resistant Enterobacter species are emerging nosocomial pathogens. As with most multidrug-resistant Gram-negative pathogens, the polymyxins are often the only therapeutic option. In this study involving clinical isolates of E. cloacae and E. aerogenes, susceptibility testing methods with polymyxin B were analyzed. All isolates underwent testing by the broth microdilution (in duplicate) and agar dilution (in duplicate) methods, and select isolates were examined by the Etest method. Selected isolates were also examined for heteroresistance by population analysis profiling. Using a susceptibility breakpoint of ≤2 μg/ml, categorical agreement by all four dilution tests (two broth microdilution and two agar dilution) was achieved in only 76/114 (67%) of E. cloacae isolates (65 susceptible, 11 resistant). Thirty-eight (33%) had either conflicting or uninterpretable results (multiple skip wells, i.e., wells that exhibit no growth although growth does occur at higher concentrations). Of the 11 consistently resistant isolates, five had susceptible MICs as determined by Etest. Heteroresistant subpopulations were detected in eight of eight isolates tested, with greater percentages in isolates with uninterpretable MICs. For E. aerogenes, categorical agreement between the four dilution tests was obtained in 48/56 (86%), with conflicting and/or uninterpretable results in 8/56 (14%). For polymyxin susceptibility testing of Enterobacter species, close attention must be paid to the presence of multiple skip wells, leading to uninterpretable results. Susceptibility also should not be assumed based on the results of a single test. Until the clinical relevance of skip wells is defined, interpretation of polymyxin susceptibility tests for Enterobacter species should be undertaken with extreme caution. PMID:24088860
Lee, Shoou-Yih Daniel; Stucky, Brian D; Lee, Jessica Y; Rozier, R Gary; Bender, Deborah E
2010-01-01
Objective The intent of the study was to develop and validate a comparable health literacy test for Spanish-speaking and English-speaking populations. Study Design The design of the instrument, named the Short Assessment of Health Literacy—Spanish and English (SAHL-S&E), combined a word recognition test, as appearing in the Rapid Estimate of Adult Literacy in Medicine (REALM), and a comprehension test using multiple-choice questions designed by an expert panel. We used the item response theory (IRT) in developing and validating the instrument. Data Collection Validation of SAHL-S&E involved testing and comparing the instrument with other health literacy instruments in a sample of 201 Spanish-speaking and 202 English-speaking subjects recruited from the Ambulatory Care Center at the University of North Carolina Healthcare System. Principal Findings Based on IRT analysis, 18 items were retained in the comparable test. The Spanish version of the test, SAHL-S, was highly correlated with other Spanish health literacy instruments, Short Assessment of Health Literacy for Spanish-Speaking Adults (r=0.88, p<.05) and the Spanish Test of Functional Health Literacy in Adults (TOFHLA) (r=0.62, p<.05). The English version, SAHL-E, had high correlations with REALM (r=0.94, p<.05) and the English TOFHLA (r=0.68, p<.05). Significant correlations were found between SAHL-S&E and years of schooling in both Spanish- and English-speaking samples (r=0.15 and 0.39, respectively). SAHL-S&E displayed satisfactory reliability of 0.80 and 0.89 in the Spanish- and English-speaking samples, respectively. IRT analysis indicated that the SAHL-S&E score was highly reliable for individuals with a low level of health literacy. Conclusions The new instrument, SAHL-S&E, has good reliability and validity. It is particularly useful for identifying individuals with low health literacy and could be used to screen for low health literacy among Spanish and English speakers. PMID:20500222
Yang, Mingming; Zhao, Yuting; Wang, Limin; Paulsen, Michael; Simpson, Christopher D; Liu, Fengquan; Du, Dan; Lin, Yuehe
2018-05-01
A novel sandwich immunoassay based immunochromatographic test strip (ICTS) has been developed for simultaneously measuring both butyrylcholinesterase (BChE) activity and the total amount of BChE (including inhibited and active enzyme) from 70 μLpost-exposure human plasma sample. The principle of this method is based on the BChE monoclonal antibody (MAb) capable of acting as both capture antibody and detection antibody. The BChE MAb which was immobilized on the test line was able to recognize both organophosphorus BChE adducts (OP-BChE) and BChE and provided equal binding affinity, permitting detection of the total enzyme amount in post-exposure human plasma samples. The formed immunocomplexes on the test line can further be excised from the test-strip for subsequent off-line measurement of BChE activity using the Ellman assay. Therefore, dual biomarkers of BChE activity and phosphorylation (OP-BChE) will be obtained simultaneously. The whole sandwich-immunoassay was performed on one ICTS, greatly reducing analytical time. The ICTS sensor showed excellent linear responses for assaying total amount of BChE and active BChE ranging from 0.22 to 3.58nM and 0.22-7.17nM, respectively. Both the signal detection limits are 0.10nM. We validated the practical application of the proposed method to measure 124 human plasma samples from orchard workers and cotton farmers with long-term exposure to organophosphorus pesticides (OPs). The results were in highly agreement with LC/MS/MS which verified our method is extremely accurate. Combining the portability and rapidity of test strip and the compatibility of BChE MAb as both capture antibody and detection antibody, the developed method provides a baseline-free, low-cost and rapid tool for in-field monitoring of OP exposures. Copyright © 2018 Elsevier B.V. All rights reserved.
Co-combustion of E+E waste plastics in the TAMARA test plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vehlow, J.; Wanke, T.; Bergfeldt, B.
1997-12-01
The co-combustion of different amounts of various plastic fractions of electrical and electronic (E+E) waste together with municipal solid waste has been tested in the Karlsruhe test incinerator TAMARA. The tests revealed no negative influences upon the combustion process. In general the increased heating value of the fuel causes an improved burnout in all residue streams. The halogens Cl and Br added with the plastics are mainly transferred as HCl or HBr into the flue gas. An influence upon the formation of chlorinated dioxins and furans could not be observed. With increasing Br feed bromine containing homologues were detected inmore » the raw gas. The furans formed easier than the dioxins and those homologues carrying one Br atom were by far prevailing. Even at high Br input the total amount of mixed halogenated species was limited to approximately 30% of the total load of such compounds which did not leave the typical operation window for PCDD/PCDF in TAMARA. The co-combustion tests demonstrated that MSW combustion is an ecologically acceptable and economically sound disposal route for limited amounts of specific E+E waste.« less
16 CFR § 1203.15 - Positional stability test (roll-off resistance).
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Positional stability test (roll-off... stability test (roll-off resistance). (a) Test equipment. (1) Headforms. The test headforms shall comply with the dimensions of the full chin ISO reference headforms sizes A, E, J, M, and O. (2) Test fixture...
Does Testing Impair Relational Processing? Failed Attempts to Replicate the Negative Testing Effect
ERIC Educational Resources Information Center
Rawson, Katherine A.; Wissman, Kathryn T.; Vaughn, Kalif E.
2015-01-01
Recent research on testing effects (i.e., practice tests are more effective than restudy for enhancing subsequent memory) has focused on explaining when and why testing enhances memory. Of particular interest for present purposes, Zaromb and Roediger (2010) reported evidence that testing effects in part reflect enhanced relational processing,…
Code of Federal Regulations, 2013 CFR
2013-10-01
... completes the form, the person who gave the test shall sign it. (e) If the road test is successfully... 49 Transportation 5 2013-10-01 2013-10-01 false Road test. 391.31 Section 391.31 Transportation... COMBINATION VEHICLE (LCV) DRIVER INSTRUCTORS Tests § 391.31 Road test. (a) Except as provided in subpart G, a...
Code of Federal Regulations, 2014 CFR
2014-10-01
... completes the form, the person who gave the test shall sign it. (e) If the road test is successfully... 49 Transportation 5 2014-10-01 2014-10-01 false Road test. 391.31 Section 391.31 Transportation... COMBINATION VEHICLE (LCV) DRIVER INSTRUCTORS Tests § 391.31 Road test. (a) Except as provided in subpart G, a...
Code of Federal Regulations, 2012 CFR
2012-10-01
... completes the form, the person who gave the test shall sign it. (e) If the road test is successfully... 49 Transportation 5 2012-10-01 2012-10-01 false Road test. 391.31 Section 391.31 Transportation... COMBINATION VEHICLE (LCV) DRIVER INSTRUCTORS Tests § 391.31 Road test. (a) Except as provided in subpart G, a...
Code of Federal Regulations, 2010 CFR
2010-10-01
... completes the form, the person who gave the test shall sign it. (e) If the road test is successfully... 49 Transportation 5 2010-10-01 2010-10-01 false Road test. 391.31 Section 391.31 Transportation... COMBINATION VEHICLE (LCV) DRIVER INSTRUCTORS Tests § 391.31 Road test. (a) Except as provided in subpart G, a...
Some Considerations in Maintaining Adaptive Test Item Pools.
ERIC Educational Resources Information Center
Stocking, Martha L.
The construction of parallel editions of conventional tests for purposes of test security while maintaining score comparability has always been a recognized and difficult problem in psychometrics and test construction. The introduction of new modes of test construction, e.g., adaptive testing, changes the nature of the problem, but does not make…
Optimizing Multiple-Choice Tests as Learning Events
ERIC Educational Resources Information Center
Little, Jeri Lynn
2011-01-01
Although generally used for assessment, tests can also serve as tools for learning--but different test formats may not be equally beneficial. Specifically, research has shown multiple-choice tests to be less effective than cued-recall tests in improving the later retention of the tested information (e.g., see meta-analysis by Hamaker, 1986),…
EMC Test Report: StangSat - CubeSat Program
NASA Technical Reports Server (NTRS)
Carmody, Lynne M.; Aragona, Peter S.
2013-01-01
This report documents the Electromagnetic Interference E M I testing performed on the StangSat; the unit under test (UUT). Testing was per the requirements of MIL STD-461F. The UUT was characterized and passed the radiated emissions (RE102 limit for Spacecraft) testing.
42 CFR 493.845 - Standard; Toxicology.
Code of Federal Regulations, 2012 CFR
2012-10-01
... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...
42 CFR 493.851 - Standard; Hematology.
Code of Federal Regulations, 2014 CFR
2014-10-01
... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...
42 CFR 493.843 - Standard; Endocrinology.
Code of Federal Regulations, 2013 CFR
2013-10-01
... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...
42 CFR 493.845 - Standard; Toxicology.
Code of Federal Regulations, 2014 CFR
2014-10-01
... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...
42 CFR 493.845 - Standard; Toxicology.
Code of Federal Regulations, 2013 CFR
2013-10-01
... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...
42 CFR 493.851 - Standard; Hematology.
Code of Federal Regulations, 2013 CFR
2013-10-01
... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...
42 CFR 493.843 - Standard; Endocrinology.
Code of Federal Regulations, 2012 CFR
2012-10-01
... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...
42 CFR 493.843 - Standard; Endocrinology.
Code of Federal Regulations, 2014 CFR
2014-10-01
... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...
42 CFR 493.851 - Standard; Hematology.
Code of Federal Regulations, 2012 CFR
2012-10-01
... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...
ERIC Educational Resources Information Center
Fox, Janna; Cheng, Liying
2015-01-01
In keeping with the trend to elicit multiple stakeholder responses to operational tests as part of test validation, this exploratory mixed methods study examines test-taker accounts of an Internet-based (i.e., computer-administered) test in the high-stakes context of proficiency testing for university admission. In 2013, as language testing…
40 CFR 86.1305 - Introduction; structure of subpart.
Code of Federal Regulations, 2014 CFR
2014-07-01
... this part. (e) Use the fuels specified in 40 CFR part 1065 to perform valid tests, as follows: (1) For service accumulation, use the test fuel or any commercially available fuel that is representative of the... subpart A of this part in a given model year based on this E0 test fuel if those engines are certified...
26 CFR 1.48-10 - Single purpose agricultural or horticultural structures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... test if either of the requirements of paragraph (e)(1)(i) of this section is not met. Thus, for example... the structure to fail the exclusive use test when the change occurs. Thus, for example, a hog-raising... example). Finally, the structure fails the incidental use test of paragraph (e) of this section because...
26 CFR 1.48-10 - Single purpose agricultural or horticultural structures.
Code of Federal Regulations, 2013 CFR
2013-04-01
... test if either of the requirements of paragraph (e)(1)(i) of this section is not met. Thus, for example... the structure to fail the exclusive use test when the change occurs. Thus, for example, a hog-raising... example). Finally, the structure fails the incidental use test of paragraph (e) of this section because...
40 CFR Appendix E to Subpart S of... - Transient Test Driving Cycle
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Transient Test Driving Cycle E Appendix... Driving Cycle (I) Driver's trace. All excursions in the transient driving cycle shall be evaluated by the... shall cause a test to be void. In addition, provisions shall be available to utilize cycle validation...
Organizational Analysis of the United States Army Evaluation Center
2014-12-01
analysis of qualitative or quantitative data obtained from design reviews, hardware inspections, M&S, hardware and software testing , metrics review... Research Development Test & Evaluation (RDT&E) appropriation account. The Defense Acquisition Portal ACQuipedia website describes RDT&E as “ one of the... research , design , development, test and evaluation, production, installation, operation, and maintenance; data collection; processing and analysis
Validating Test Score Meaning and Defending Test Score Use: Different Aims, Different Methods
ERIC Educational Resources Information Center
Cizek, Gregory J.
2016-01-01
Advances in validity theory and alacrity in validation practice have suffered because the term "validity" has been used to refer to two incompatible concerns: (1) the degree of support for specified interpretations of test scores (i.e. intended score meaning) and (2) the degree of support for specified applications (i.e. intended test…
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
Anaphylaxis from the influenza virus vaccine.
Coop, Christopher A; Balanon, Synya K; White, Kevin M; Whisman, Bonnie A; Rathkopf, Melinda M
2008-01-01
Allergic reactions to the influenza vaccine are uncommon and usually associated with sensitivity to egg or gelatin. The aim of this study was to report the case of anaphylaxis to the influenza vaccine. Allergy percutaneous skin testing, serum specific IgE testing and IgE immunoblotting were performed to the influenza vaccine, egg, and gelatin. Percutaneous skin testing to the influenza vaccine and gelatin were positive and egg (white, whole, and yolk) was negative. Immunocap serum-specific IgE testing to egg (white, whole, and yolk) and gelatin were negative (<0.35 kU/l). IgE immunoblots were performed with 2 cord blood serums and the patient's serum at a 1:20 dilution against 10 microg of the Fluzone influenza vaccine. The patient's IgE immunoblot showed a protein band at 100 kDa which is similar to the molecular weight of gelatin protein, a 68-kDa protein which is similar to the molecular weight of hemagglutinin protein from the influenza vaccine, and a 45-kDa protein band that is similar to the molecular weight of ovalbumin protein from chicken embryo/egg. Based on clinical symptoms, skin testing, Immunocap testing and immunoblot evaluation, we feel that our patient is allergic to the infectious agent in the influenza vaccine as well as gelatin and ovalbumin in egg. Copyright 2007 S. Karger AG, Basel.
kruX: matrix-based non-parametric eQTL discovery.
Qi, Jianlong; Asl, Hassan Foroughi; Björkegren, Johan; Michoel, Tom
2014-01-14
The Kruskal-Wallis test is a popular non-parametric statistical test for identifying expression quantitative trait loci (eQTLs) from genome-wide data due to its robustness against variations in the underlying genetic model and expression trait distribution, but testing billions of marker-trait combinations one-by-one can become computationally prohibitive. We developed kruX, an algorithm implemented in Matlab, Python and R that uses matrix multiplications to simultaneously calculate the Kruskal-Wallis test statistic for several millions of marker-trait combinations at once. KruX is more than ten thousand times faster than computing associations one-by-one on a typical human dataset. We used kruX and a dataset of more than 500k SNPs and 20k expression traits measured in 102 human blood samples to compare eQTLs detected by the Kruskal-Wallis test to eQTLs detected by the parametric ANOVA and linear model methods. We found that the Kruskal-Wallis test is more robust against data outliers and heterogeneous genotype group sizes and detects a higher proportion of non-linear associations, but is more conservative for calling additive linear associations. kruX enables the use of robust non-parametric methods for massive eQTL mapping without the need for a high-performance computing infrastructure and is freely available from http://krux.googlecode.com.
Qiao, H-L; Li, Z; Yang, J; Tian, X; Gao, N; Jia, L-J
2009-06-01
Although skin tests are usually employed to evaluate current penicillin allergy status, a negative result does not exclude hypersensitivity. There is a need for accurate in vitro tests to exclude hypersensitivity. A radioallergosorbent test (RAST) is a potentially good supplementary approach, but there is little information on the suitability of this method to diagnose penicillin hypersensitivity in subjects with a negative skin test to benzylpenicillin. A total of 133 patients with a negative skin test to benzylpenicillin G (PG) and all of whom developed allergic reactions to PG were studied. RAST was used to detect eight kinds of specific IgE antibodies to penicillins in serum, which included four kinds of major and minor antigenic determinants to four penicillin drugs. The combination sites for the specific IgE antibodies were studied by RAST inhibition test. The rate of positive reactions for the specific IgE antibodies was 59.40% (79/133). Of the eight kinds of antigenic determinants, the positive rates for specific IgE against the major and minor determinants were 39.10% (52) and 42.86% (57) respectively. Of the four drugs, positive cases only to PG were 10 (7.5%), were significantly fewer than the cross-reacting positive cases (36) to PG (P < 0.01). In the RAST inhibition studies all drugs exhibited good inhibitory potencies, and in some instances the side-chain of the penicillins could induce specific responses with a variable degree of cross-reactivity among the different penicillins. Radioallergosorbent test is a good complementary test in persons who are skin-test negative with PG, and the sensitivity of RAST increases with increasing specificity of IgE antibodies to be detected. 6-APA and the groups, making part of the different side-chains on penicillins, all contributed to the cross-reactivity.
The Wilcoxon signed rank test for paired comparisons of clustered data.
Rosner, Bernard; Glynn, Robert J; Lee, Mei-Ling T
2006-03-01
The Wilcoxon signed rank test is a frequently used nonparametric test for paired data (e.g., consisting of pre- and posttreatment measurements) based on independent units of analysis. This test cannot be used for paired comparisons arising from clustered data (e.g., if paired comparisons are available for each of two eyes of an individual). To incorporate clustering, a generalization of the randomization test formulation for the signed rank test is proposed, where the unit of randomization is at the cluster level (e.g., person), while the individual paired units of analysis are at the subunit within cluster level (e.g., eye within person). An adjusted variance estimate of the signed rank test statistic is then derived, which can be used for either balanced (same number of subunits per cluster) or unbalanced (different number of subunits per cluster) data, with an exchangeable correlation structure, with or without tied values. The resulting test statistic is shown to be asymptotically normal as the number of clusters becomes large, if the cluster size is bounded. Simulation studies are performed based on simulating correlated ranked data from a signed log-normal distribution. These studies indicate appropriate type I error for data sets with > or =20 clusters and a superior power profile compared with either the ordinary signed rank test based on the average cluster difference score or the multivariate signed rank test of Puri and Sen. Finally, the methods are illustrated with two data sets, (i) an ophthalmologic data set involving a comparison of electroretinogram (ERG) data in retinitis pigmentosa (RP) patients before and after undergoing an experimental surgical procedure, and (ii) a nutritional data set based on a randomized prospective study of nutritional supplements in RP patients where vitamin E intake outside of study capsules is compared before and after randomization to monitor compliance with nutritional protocols.
12 CFR 563e.28 - Assigned ratings.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Assigned ratings. 563e.28 Section 563e.28 Banks... for Assessing Performance § 563e.28 Assigned ratings. (a) Ratings in general. Subject to paragraphs (b... performance under the lending, investment and service tests, the community development test, the small savings...
Anti-E Detected in a 7-Month-Old Infant with Acute Lymphoblastic Leukemia after Transfusion.
Kumeta, Mai; Tanaka, Kazuto; Kaneko, Natsuki; Osanai, Takayuki; Ajima, Hikaru; Tamai, Yoshiko; Kayaba, Hiroyuki; Ito, Etsuro; Saito, Norihiro
2018-06-01
Only a few cases of infantile anti-red blood cell alloantibody production have been reported. A 7-month-old girl with acute lymphoid leukemia developed anti-E alloantibody 13 days after transfusion of E-positive red blood cells. Antibody screening was performed before and at 2, 6, 13, 18, 27, 34, and 49 days after red blood cell transfusion. Identification test, direct immunoglobulin test, acid elution, and dithiothreitol test were also performed. Anti-E alloantibody was detected in the blood 13 days after the first transfusion. The detected antibody was IgM and it decreased below detectable levels within 49 days after the first transfusion. Follow-up testing for the presence of post-transfusion alloantibody at appropriate times is important, even in infants.
Zivanovic, Mirjana; Atanasković-Marković, Marina; Medjo, Biljana; Gavrović-Jankulović, Marija; Smiljanić, Katarina; Tmušić, Vladimir; Djurić, Vojislav
2017-04-01
IgE- mediated food allergy affects 6-8% of children. Our study aimed to define the correlations between the results obtained with skin prick tests (SPTs) using commercial extracts and fresh foods, and the correlations between these result and those obtained with specific IgE (sIgE) and/ or challenge. Children aged from 2 months to 6 years were recruited prospectively. Overall 571 children were positive to one food. In all children we performed SPT using commercial extracts of suspected food and fresh foods and sIgE. If SPT and sIgE test results did not correspond to the history, we performed open oral food challenge. Sensitivity of SPT with commercial extracts for all tested food was poor (3-35%), while sensitivity of fresh food skin prick tests (FFSPT) was excellent (50-100%), and showed correlation with open oral food challenge (p<0.001). Our results suggest that fresh food extracts are more effective in detecting sensitization and with levels of sIgE greater than class 3 could predict clinical reactivity, without the need for potentially hazardous food challenges.
Evaluation of basophil activation test in suspected food hypersensitivity.
Pignatti, Patrizia; Yacoub, Mona-Rita; Testoni, Claudia; Pala, Gianni; Corsetti, Maura; Colombo, Giselda; Meriggi, Antonio; Moscato, Gianna
2017-07-01
Food hypersensitivity is characterized by a wide range of symptoms. The relationship between symptoms and food is more frequently suspected than objectively proven. Basophil activation test (BAT) is based on the evaluation of activation markers on blood basophils in vitro stimulated with drugs or allergens. The aim of the study was to evaluate the usefulness of BAT when introduced in the routine work-up of suspected food hypersensitivity. BAT was requested in subjects with food adverse reactions when a discrepancy existed among history and skin prick test (SPT) and/or specific IgE. Data from 150 subjects were analysed using CD63 as basophil activation marker. Thirty controls were evaluated for cut-offs. Immunoblots was performed with the sera of representative subjects positive for BAT and negative for SPT and sIgE. 1,024 BAT were carried out, the agreement (positive/positive and negative/negative) was 78.5% for BAT vs. SPT and 78.3% for BAT vs. IgE. Atopic patients, but not atopic controls, more frequently had a positive BAT than non-atopic patients (P < 0.0001). Among subjects with positive BAT, those with negative sIgE had lower total IgE, P = 0.001. Nearly 23.3% of all subjects had positive BAT (for at least one tested food) and both negative sIgE and SPT. Immunoblots revealed the presence of sIgE for the tested foods in representative patients with positive BAT, negative SPT and sIgE. Introduction of BAT in routine of food hypersensitivity, limited to subjects with a discrepancy between history and traditional tests, might be useful particularly when total IgE are low. © 2015 International Clinical Cytometry Society. © 2015 International Clinical Cytometry Society.
Thorne, D; Hollings, M; Seymour, A; Adamson, J; Dalrymple, A; Ballantyne, M; Gaca, M
2018-04-01
There is a growing consensus that e-cigarettes hold the potential for reducing the harm associated with cigarette smoking. Recently published studies have reported in vitro testing of e-cigarettes, demonstrating reduced toxicological and biological effects. Few studies however have reported the use of e-cigarettes under extreme testing conditions. To assess the full mutagenic potential of a commercially available electronic-cigarette (Vype ePen), this study investigated the delivery of aerosol under extreme conditions, using a scaled-down 35 mm plate Ames bacterial reverse mutagenicity assay. S. typhimurium strains TA98, TA100, TA97, TA104 and E. coli WP2 uvrA pKM101 with or without metabolic activation (S9), were employed. Using a modified Vitrocell VC 10 exposure system 0, 180, 360, 540, 720 or 900 puffs of undiluted e-cigarette aerosol was generated and delivered to bacterial cultures aligned to reported human consumption data. The results demonstrate that no mutagenic activity was observed in any strain under any test condition even when exposed to 900 puffs of undiluted e-cigarette aerosols +/- S9. Positive control responses were observed in all strains +/- S9. Nicotine assessments demonstrated an increased and consistent aerosol delivery, with calculated maximum doses of ∼1 mg/mL delivery of nicotine. These data demonstrate the validity of this unique testing approach and adds further information to the growing weight of evidence that e-cigarettes offer substantially reduced exposure when compared to conventional cigarette smoke. For future in vitro assessments of next generation tobacco and nicotine products, the generation, delivery and testing of undiluted aerosols can now be considered. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Fiocchi, Alessandro; Besana, Roberto; Rydén, Ann-Christine; Terracciano, Luigi; Andreotti, Massimo; Arrigoni, Sergio; Martelli, Alberto
2004-10-01
Allergy-like symptoms are common in young children, but the case history and physical examination cannot identify the underlying origins of overlapping symptom profiles. To evaluate a blood test, Phadiatop Infant (Pharmacia Diagnostics AB, Uppsala, Sweden), for differentiating the capability of IgE-mediated disease in young children with recurrent wheezing, eczema, or both. One hundred forty-seven children (mean age, 2.0 years) were consecutively referred to 2 allergy centers by their primary care physician for recurrent wheezing, eczema, or both. The allergist's clinical evaluation included medical history, physical examination, skin prick testing with inhalant and food allergens, and specific IgE determinations in blood. The accuracy of Phadiatop Infant was evaluated in a masked manner against the allergist's final diagnosis. Sixty-nine children had wheezing, 69 had eczema, and 9 had both symptoms. Sixty-one children were clinically diagnosed as having IgE-mediated allergy, 78 as having non-IgE-associated disease, and 8 as having an inconclusive diagnosis. Fifty-six of the 61 children with IgE-mediated allergy had positive Phadiatop Infant test results, and 64 of 78 without the condition had negative results. Sensitivity was 92% and specificity was 82%, with positive and negative predictive values of 80% and 93%, respectively. Thirteen children with a positive Phadiatop Infant test result and a negative final diagnosis were retested after 2 years; 12 of them were diagnosed as having IgE-mediated allergy using a masked evaluation. The Phadiatop Infant blood test discriminates between IgE- and non-IgE-mediated symptoms in children younger than 4 years.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miers, Scott A.; Blough, Jason R.
The objective of this study was to evaluate the effects of E15 on current and legacy snowmobile engines and vehicles that could occur due to misfueling by the vehicle owner. Three test scenarios were conducted to evaluate the impact of E15, including cold-start performance and emissions, on-snow vehicle driveability, and laboratory exhaust emissions over the useful life of the engine. The eightengines tested represent current and legacy product that may exhibit sensitivity to increased ethanol blended in gasoline. Because a limited number of snowmobile engines were evaluated for this test program, the results are not statistically significant. However, the broadmore » range of engine and mixture preparation technologies, combined with the various test scenarios provide preliminaryinformation to assess potential issues with E15 use in snowmobiles. Cold-start tests were performed at -6.7 degrees C (20 degrees F), -17.8 degrees C (0 degrees F), and -28.9 degrees C (-20 degrees F). The evaluation included time to start or number of pulls to start, engine speed, exhaust gas temperature, and start-up engine emissions concentrations. Statistically significant differences instarting times were not observed for most vehicles. Snowmobile driveability was analyzed using a subjective evaluation on a controlled test course. The drivers could not easily discern which fuel the snowmobiles were using during the subjective evaluation. Durability tests were conducted to measure the emissions and performance of the snowmobiles over the useful life of the vehicles (5,000miles). There were no fuel-related engine failures on E0 or E15. Carbon monoxide emissions were generally reduced by E15 relative to E0, by from 10% to 35%. Occasional misfueling of snowmobiles with E15 is not likely to cause noticeable or immediate problems for consumers. E15 is not approved for snowmobile use, and observations made during this study support the U.S. Environmental ProtectionAgency's decision to not approve E15 for snowmobiles.« less
DSN Network e-VLBI Calibration of Earth Orientation
NASA Technical Reports Server (NTRS)
Zhang, Liwei Dennis; Steppe, A.; Lanyi, G.; Jacobs, C.
2006-01-01
This viewgraph presentation reviews the calibration of the Earth's orientation by using the Deep Space Network (DSN) e Very Large Base Integration (VLBI). The topics include: 1) Background: TEMPO; 2) Background: UT1 Knowledge Error; 3) e-VLBI: WVSR TEMPO Overview; 4) e-VLBI: WVSR TEMPO Turnaround; 5) e-VLBI: WVSR TEMPO R&D Tests; and 6) WVSR TEMPO Test Conclusion.
Design and Testing of an Educational Water Tunnel
NASA Astrophysics Data System (ADS)
Kosaraju, Srinivas
2017-11-01
A new water tunnel is designed and tested for educational and research purposes at Northern Arizona University. The university currently owns an educational wind tunnel with a test section of 12in X 12in X 24in. However, due to limited size of test section and range of Reynolds numbers, its application is currently limited to very few experiments. In an effort to expand the educational and research capabilities, a student team is tasked to design, build and test a water tunnel as a Capstone Senior Design project. The water tunnel is designed to have a test section of 8in X 8in X 36in. and be able to test up to Re = 50E3. Multiple numerical models are used to optimize the flow field inside the test section before building the physical apparatus. The water tunnel is designed to accommodate multiple experiments for drag and lift studies. The built-in die system can deliver up to three different colors to study the streamlines and vortex shedding from the surfaces. During the first phase, a low discharge pump is used to achieve Re = 4E3 to test laminar flows. In the second phase, a high discharge pump will be used to achieve targeted Re = 50E3 to study turbulent flows.
Comparison of 3 in vivo methods for assessment of alcohol-based hand rubs.
Edmonds-Wilson, Sarah; Campbell, Esther; Fox, Kyle; Macinga, David
2015-05-01
Alcohol-based hand rubs (ABHRs) are the primary method of hand hygiene in health-care settings. ICPs increasingly are assessing ABHR product efficacy data as improved products and test methods are developed. As a result, ICPs need better tools and recommendations for how to assess and compare ABHRs. Two ABHRs (70% ethanol) were tested according to 3 in vivo methods approved by ASTM International: E1174, E2755, and E2784. Log10 reductions were measured after a single test product use and after 10 consecutive uses at an application volume of 2 mL. The test method used had a significant influence on ABHR efficacy; however, in this study the test product (gel or foam) did not significantly influence efficacy. In addition, for all test methods, log10 reductions obtained after a single application were not predictive of results after 10 applications. Choice of test method can significantly influence efficacy results. Therefore, when assessing antimicrobial efficacy data of hand hygiene products, ICPs should pay close attention to the test method used, and ensure that product comparisons are made head to head in the same study using the same test methodology. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Hamdan, Jihad M; Al-Hawamdeh, Rose Fowler
2018-04-10
This empirical study examines the extent to which 'face', i.e. (audio visual dialogues), affects the listening comprehension of advanced Jordanian EFL learners in a TOFEL-like test, as opposed to its absence (i.e. a purely audio test) which is the current norm in many English language proficiency tests, including but not limited to TOFEL iBT, TOEIC and academic IELTS. Through an online experiment, 60 Jordanian postgraduate linguistics and English literature students (advanced EFL learners) at the University of Jordan sit for two listening tests (simulating English proficiency tests); namely, one which is purely audio [i.e. without any face (including any visuals such as motion, as well as still pictures)], and one which is audiovisual/video. The results clearly show that the inclusion of visuals enhances subjects' performance in listening tests. It is concluded that since the aim of English proficiency tests such as TOEFL iBT is to qualify or disqualify subjects to work and study in western English-speaking countries, the exclusion of visuals is unfounded. In actuality, most natural interaction includes visibility of the interlocutors involved, and hence test takers who sit purely audio proficiency tests in English or any other language are placed at a disadvantage.
ERIC Educational Resources Information Center
Zheng, Yi; Nozawa, Yuki; Gao, Xiaohong; Chang, Hua-Hua
2012-01-01
Multistage adaptive tests (MSTs) have gained increasing popularity in recent years. MST is a balanced compromise between linear test forms (i.e., paper-and-pencil testing and computer-based testing) and traditional item-level computer-adaptive testing (CAT). It combines the advantages of both. On one hand, MST is adaptive (and therefore more…
Ultrafast Passive Shields for Laser and Ballistic Protection
1991-07-15
chemically polymerized P(DPA)) as a binder, and these were tested for ablation (i.e. laser damage threshold ) limits. Table IV below summarizes these results...50, 100, 250 and 500 AJ/pulse o 1.G, 2.5, 5.0 mJ/pulse. The following energies were used for the preliminary laser damage threshold tests: o 2.5, 5.0...these were tested for ablation (i.e. laser damage threshold ) limits. Table VI summarizes these results which are all for tests in the absence of an iris
Occupational Survey Report, Cardiopulmonary Laboratory, AFSC 4H0X1, OSSN: 2541
2004-02-01
patients within facility 97 E0211 Set up humidifiers 97 E0175 Instruct patients in use of incentive spirometers 97 A0031 Obtain sputum samples 97 A0026...D0137 Calibrate pulmonary function testing equipment 100 D0150 Perform routine spirometry tests 100 D0146 Perform lung diffusion tests 100 A0042 Perform...consultations, or procedures 31 D0150 Perform routine spirometry tests 23 35 TABLE A2 REPRESENTATIVE TASKS PERFORMED BY MEMBERS IN THE SUPERVISION AND
4. "TEST STAND NO. 13, CONCRETE STRUCTURAL PLAN AND ELEVATION." ...
4. "TEST STAND NO. 1-3, CONCRETE STRUCTURAL PLAN AND ELEVATION." Specifications No. OC11-50-10; Drawing No. 60-09-06; no sheet number within title block. D.O. SERIES 1109/12 REV. E. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract DA-04-353 Eng. 177, Rev. E; Date: 17 Dec. 1951. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA
11. "TEST STANDS NOS. 11, 13, & 15; CONCRETE STRUCTURAL ...
11. "TEST STANDS NOS. 1-1, 1-3, & 1-5; CONCRETE STRUCTURAL SECTIONS AND DETAILS." Specifications No. OC12-50-10; Drawing No. 60-09-04; no sheet number within title block. D.O. SERIES 1109/15, Rev. E. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract DA-04353 Eng. 177, Rev. E; Date: 21 Dec. 1951. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-5, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA
12. "TEST STANDS NOS. 11, 13, & 15; CONCRETE STRUCTURAL ...
12. "TEST STANDS NOS. 1-1, 1-3, & 1-5; CONCRETE STRUCTURAL SECTIONS AND DETAILS." Specifications No. OC12-50-10; Drawing No. 60-09-06; no sheet number within title block. D.O. SERIES 1109/16, Rev. E. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract DA-04353 Eng. 177, Rev. E; Date: 26 Dec. 1951. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-5, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baggu, Murali
2017-01-01
This project will enable effective utilization of high penetration of photovoltaics (PV) in islanded microgrids, increasing overall system efficiency, decreased fuel costs and resiliency of the overall system to help meet the SunShot goals of enhancing system integration methods to increase penetration of PV. National Renewable Energy Laboratory (NREL) will collaborate with San Diego Gas & Electric (SDG&E) to provide research and testing support to address their needs in energy storage sizing and placement, Integrated Test Facility (ITF) development, Real Time Digital Simulator (RTDS) Modeling and simulation support at ITF, Visualization and Virtual connection to Energy Systems Integration Facility (ESIF),more » and microgrid simulation and testing areas. Specifically in this project a real microgrid scenario with high penetration of PV (existing in SDG&E territory) is tested in the ESIF laboratory. Multiple control cases for firming PV using storage in a microgrid scenario will be investigated and tested in the laboratory setup.« less
21 CFR 862.1815 - Vitamin E test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... treatment of infants with vitamin E deficiency syndrome. (b) Classification. Class I (general controls). The...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, D.C.; Ober, D.G.; Goodrow, J.T.
1995-09-01
ASTM E 283 ad ASTM E 1424 in conjunction with ASTM C 976 were used to study the effect of airflow on thermal performance of the wall. A typical residential 2 {times} 4 stud wall was constructed and placed on top of a subfloor, making a 2.44 {times} 2.74 m (8 by 9 ft) test specimen. This base wall assembly was then covered with two types of XPS sheathing, various housewraps, a 15{number_sign} felt, and a polyethylene vapor retarder film in 40 different configurations and tested individually per ASTM E 283 and per ASTM C 976. For 24 of themore » 40 C 976 tests, a differential pressure was induced across the test wall as per and ASTM E 1424. Airflows ranged from undetectable airflow at 0 {center_dot} Pa {Delta}P to 1.63 L/s {center_dot} m{sup 2} for the base wall assembly alone. Difference in airflow resistance performance between the ASTM E 283 and ASTM E 1424 test methods were noted. Thermal testing results incorporating both ASTM C 976 and ASTM E 1424 for tests 1--28 produced apparent thermal conductances (C-values) in the range of 0.40 W/m{sup 2} {center_dot} K for a nondetectable airflow level to 1.81 W/m{sup 2} {center_dot} K for an airflow of 1.53 L/s {center_dot} m{sup 2} for the base wall assembly alone with a 20-Pa {Delta}P. The calculated C-value for this base wall assembly was 0.40 W/m{sup 2} {center_dot} K. Test results reveal that airflow rates as low as 0.2 L/s {center_dot} m{sup 2} could produce a 46% increase in apparent C-value. Similar thermal performance differences were revealed when thicker shiplap XPS sheathing was used. Tests were also conducted using an Air-Tight Drywall configuration showing the effect of wind washing on thermal performance. By sealing the gypsum drywall on the base wall assembly tested, the apparent C-value, when exposed to a 12.5 Pa wind pressure, was found to be equivalent to a base wall assembly configuration which allows 0.15 L/s {center_dot} m{sup 2} airflow to penetrate completely through.« less
[Penicillin allergy as a diagnostic problem. Overview and personal studies].
Walker, T; Jung, E G; Bayerl, C
2000-11-01
Penicillin allergy is a common clinical problem. The distinction between penicillin and para-infectious exanthems is difficult. We investigated the reliability of the history, as well as the sensitivity and specificity of skin tests and specific IgE levels. 160 patients with a history of penicillin allergy were retrospectively evaluated in the outpatient department of a dermatological clinic. Nearly 50% were diagnosed as allergic to penicillin by detection of specific IgE or skin test. About 60% of the patients with immediate type reactions, and 72% with maculo-papular erythema showed positive reactions in skin tests. Significantly more patients were diagnosed as allergic to penicillin by intradermal testing than by prick testing (p < 0.05). The sensitivity of the specific IgE RAST was 17.9%; the specifity, 89.5%. For the prick test the sensitivity was 8.2%; the specificity 90.8%. For the intradermal test the sensitivity was 26%; the specifity 69.7%. We suggest a step by step procedure to detect penicillin allergy making the diagnostic results as valid as possible.
Akkaya, A; Ornek, Z; Kaleli, S
2004-01-01
This study was aimed to determine the rate of occupational asthma (OA) in workers at a rose extracting plant. Specific clinical tests of 52 workers, randomly chosen from four local rose extracting plants, were statistically compared with the test results of 30 local control subjects of similar age and sex as the plant workers, but who had never worked in such a plant. There were no significant differences in pulmonary function tests (FVC, FEV1, FEV1/FVC, PEFR) between the control and test groups. Significantly higher serum total IgE values (p < 0.0001) were observed for the test subjects (239.08+/-240 IU/ml) compared to the control subjects (81.33+/-61.45 IU/ml). There were also significant differences (p < 0.0001) in the number of eosinophils between the control and test groups, with corresponding mean values of 2.28+/-2.75% and 0.73+/-1.72%, respectively. A specifically prepared skin prick test using a rose allergen (Rosa domescena) was positive for 53.84% in the test subjects whereas only 5.33% positive test results were seen in the control group. We have demonstrated the involvement of Rosa domescena pollen in occupational allergy, through IgE-mediated hypersensitivity. It was concluded that the workers of a rose oil extracting plant are more susceptible to the rose pollens.
40 CFR 91.405 - Recorded information.
Code of Federal Regulations, 2014 CFR
2014-07-01
... addition to a pre- and post-test measurement. (4) Recorder chart or equivalent. Identify for each test... each mode, if applicable. (8) Exhaust sample line temperature, if applicable. (e) Test data; post-test...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.405 Recorded...
40 CFR 91.405 - Recorded information.
Code of Federal Regulations, 2012 CFR
2012-07-01
... addition to a pre- and post-test measurement. (4) Recorder chart or equivalent. Identify for each test... each mode, if applicable. (8) Exhaust sample line temperature, if applicable. (e) Test data; post-test...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.405 Recorded...
40 CFR 91.405 - Recorded information.
Code of Federal Regulations, 2011 CFR
2011-07-01
... addition to a pre- and post-test measurement. (4) Recorder chart or equivalent. Identify for each test... each mode, if applicable. (8) Exhaust sample line temperature, if applicable. (e) Test data; post-test...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.405 Recorded...
40 CFR 91.405 - Recorded information.
Code of Federal Regulations, 2013 CFR
2013-07-01
... addition to a pre- and post-test measurement. (4) Recorder chart or equivalent. Identify for each test... each mode, if applicable. (8) Exhaust sample line temperature, if applicable. (e) Test data; post-test...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.405 Recorded...
40 CFR 91.405 - Recorded information.
Code of Federal Regulations, 2010 CFR
2010-07-01
... addition to a pre- and post-test measurement. (4) Recorder chart or equivalent. Identify for each test... each mode, if applicable. (8) Exhaust sample line temperature, if applicable. (e) Test data; post-test...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.405 Recorded...
2011-09-15
E-2 Test Stand team members at Stennis Space Center conducted their first series of tests on a three-module chemical steam generator unit Sept. 15. All three modules successfully fired during the tests. The chemical steam generator is a critical component for the A-3 Test Stand under construction at Stennis.
76 FR 69595 - Application of Third Party Testing Requirements; Reducing Third Party Testing Burdens
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-08
... subject to a third party testing requirement. Please identify specific technologies, except for those that... evaluate testing or screening technologies for consumer products (e.g., accuracy, precision, repeatability... than testing technologies? Should screening technologies be allowed only for third party conformity...
NASA Tests 2nd RS-25 Flight Engine for Space Launch System
2017-10-19
Engineers at NASA’s Stennis Space Center in Mississippi on Oct. 19 completed a hot-fire test of RS-25 rocket engine E2063, a flight engine for NASA’s new Space Launch System (SLS) rocket. Engine E2063 is scheduled to help power SLS on its Exploration Mission-2 (EM-2), the first flight of the new rocket to carry humans. Flight engine E2059 was tested on March 10, 2016, also for use on the EM-2 flight.
NASA Tests 2nd RS-25 Flight Engine For Space Launch System
2017-10-19
Engineers at NASA’s Stennis Space Center in Mississippi on Oct. 19 completed a hot-fire test of RS-25 rocket engine E2063, a flight engine for NASA’s new Space Launch System (SLS) rocket. Engine E2063 is scheduled to help power SLS on its Exploration Mission-2 (EM-2), the first flight of the new rocket to carry humans. Flight engine E2059 was tested on March 10, 2016, also for use on the EM-2 flight.
Video File - NASA Tests 2nd RS-25 Flight Engine for Space Launch System
2017-10-19
Engineers at NASA’s Stennis Space Center in Mississippi on Oct. 19 completed a hot-fire test of RS-25 rocket engine E2063, a flight engine for NASA’s new Space Launch System (SLS) rocket. Engine E2063 is scheduled to help power SLS on its Exploration Mission-2 (EM-2), the first flight of the new rocket to carry humans. Flight engine E2059 was tested on March 10, 2016, also for use on the EM-2 flight.
Mechanical Properties of Misers Bluff Sand.
1986-09-01
in Chapter 4. 4 .7 Y~ e -~1 % CHAPTER 2 LABORATORY TESTS 2.1 CONVENTIONAL SOIL TESTS Samples of MB sand were split from the available supply of...air Va , and void ratio e (the ratio of void volume to solid volume). These composition data are listed in Table 2.1 for each test. 5 2.3 MECHANICAL...and diameter changes are made. The data can be plotted as principal stress difference versus axial strain, the slope of which is Young’s modulus E
The Test and Evaluation Uses of Heterogeneous Computing: GPGPUs and Other Approaches
2011-03-01
is commonly held that test and evaluation (T& E ) is one of the most critical steps in the development of virtually all defense systems (Fox et al. 2003...T& E of current systems is an elaborate and time-consuming process that reflects both the intricacies of the object of the test and the range of...bases (Kepner 2004). These questions are even more urgent because increasing emphasis in T& E concerns the expenditures of money and time in the
Research and Development in Support of the Navy Technology Center for Safety and Survivability
1990-10-26
Patterson AFB, OH. W. E.; Naegeli , D. W.; Valtierra, M. L. An Alternate Test Proce-Black, B. H, M.S. Thesis, Southeastern Massachusetts University, dure to...Cuellar, Jr., J. P.; Dodge, L. G.; Likos, W. E.; Naegeli , D. W.; Valtierra, M. L. "An Alternative Test Procedure to Qualify Fuels for Navy Aircraft...Likos, W.E., Naegeli , D.W., Valtierra, M.L.; "An Alternative Test Proure to Qualify Fuels for Navy Aircraft," Final Report, Naval Air Propulsion Center
1. West elevations of barrier (Building 4216/E17) and Monitor Building ...
1. West elevations of barrier (Building 4216/E-17) and Monitor Building (4203/E-4). Barrier is built of wood infilled with earth, intended to protect Monitor Building from flying debris should anything at Test Stand 'A' explode. Building 4203/E-4 is built of reinforced concrete; equipment on top of it is cooling tower for refrigeration equipment in Test Stand 'A' machinery room. Electrical utility poles are typical at the facility, and carry 4,800 volts 3-phase alternating current. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Control Center, Edwards Air Force Base, Boron, Kern County, CA
D'Ascoli, T A; Mursu, J; Voutilainen, S; Kauhanen, J; Tuomainen, T-P; Virtanen, J K
2016-08-01
Fish intake and the long-chain omega-3 polyunsaturated fatty acids (PUFAs) in fish have been suggested to lower the risk of cognitive decline. We assessed whether serum long-chain omega-3 PUFAs eicosapentaenoic acid (EPA), docosapentaenoic acid (DPA) and docosahexaenoic acid (DHA) are associated with performance on neuropsychological tests in an older population and whether exposure to methylmercury, mainly from fish, or apolipoprotein-E4 (Apo-E4) phenotype can modify the associations. A total of 768 participants from the population-based Kuopio Ischaemic Heart Disease Risk Factor Study were included. Cognitive function was measured using five neuropsychological tests: the Trail Making Test, the Verbal Fluency Test, the Selective Reminding Test, the Visual Reproduction Test and the Mini Mental State Exam. Multivariate-adjusted analysis of covariance and linear regression were used to analyze the cross-sectional associations. We found statistically significant associations between serum EPA+DPA+DHA and better performance in the Trail Making Test and the Verbal Fluency Test. The individual associations with EPA and DHA were similar with the findings with EPA+DPA+DHA, although the associations with DHA were stronger. No associations were observed with serum DPA. Pubic hair mercury content was associated only with a worse performance in the Trail Making Test, and mercury had only little impact on the associations between the serum PUFAs and cognitive performance. Apo-E4 phenotype did not modify the associations with PUFAs or mercury. Higher serum long-chain omega-3 PUFA concentrations were associated with better performance on neuropsychological tests of frontal lobe functioning in older men and women. Mercury exposure or Apo-E4 phenotype had little impact on cognitive performance.
[E-learning with journal articles].
Adriaanse, Marcel T; van Eijsden, Pieter; de Leeuw, Peter W
2014-01-01
E-learning is a popular method of continuous medical education (CME) which is becoming increasingly available to doctors. A specific form of E-learning is an online knowledge test accompanying a journal article. CME accreditation points can be obtained by reading an article and then answering test questions on it. This is a user-friendly form of CME which an increasing number of journals are offering as a service to their readers. The Dutch Journal of Medicine (NTvG) has been offering accredited tests to its readers since 2011. On comparison with international journals, a high standard has been set by the development of a test concept in which interpretation and reflection play integral roles. In the Dutch setting, the concept of the test was developed by professional bodies working closely together and it is a concept that is used as an example to other journals.
21 CFR 862.3040 - Alcohol test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862... alcohol (e.g., ethanol, methanol, isopropanol, etc.) in human body fluids (e.g., serum, whole blood, and...
21 CFR 862.3040 - Alcohol test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862... alcohol (e.g., ethanol, methanol, isopropanol, etc.) in human body fluids (e.g., serum, whole blood, and...
21 CFR 862.3040 - Alcohol test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862... alcohol (e.g., ethanol, methanol, isopropanol, etc.) in human body fluids (e.g., serum, whole blood, and...
Acceptance test report for portable exhauster POR-007/Skid E
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kriskovich, J.R.
1998-07-24
This document describes Acceptance Testing performed on Portable Exhauster POR-007/Skid E. It includes measurements of bearing vibration levels, pressure decay testing, programmable logic controller interlocks, high vacuum, flow and pressure control functional testing. The purpose of Acceptance testing documented by this report was to demonstrate compliance of the exhausters with the performance criteria established within HNF-0490, Rev. 1 following a repair and upgrade effort at Hanford. In addition, data obtained during this testing is required for the resolution of outstanding Non-conformance Reports (NCR), and finally, to demonstrate the functionality of the associated software for the pressure control and high vacuummore » exhauster operating modes provided for by W-320. Additional testing not required by the ATP was also performed to assist in the disposition and close out of receiving inspection report and for application design information (system curve). Results of this testing are also captured within this document.« less
Tests Enhance the Transfer of Learning
ERIC Educational Resources Information Center
Rohrer, Doug; Taylor, Kelli; Sholar, Brandon
2010-01-01
Numerous learning studies have shown that if the period of time devoted to studying information (e.g., casa-house) includes at least 1 test (casa-?), performance on a final test is improved--a finding known as the "testing effect". In most of these studies, however, the final test is identical to the initial test. If the final test…
Galileo battery testing and the impact of test automation
NASA Technical Reports Server (NTRS)
Pertuch, W. T.; Dils, C. T.
1985-01-01
Test complexity, changes of test specifications, and the demand for tight control of tests led to the development of automated testing used for Galileo and other projects. The use of standardized interfacing, i.e., IEEE-488, with desktop computers and test instruments, resulted in greater reliability, repeatability, and accuracy of both control and data reporting. Increased flexibility of test programming has reduced costs by permitting a wide spectrum of test requirements at one station rather than many stations.
Basophil-activation tests in Hymenoptera allergy.
Dubois, Anthony E J; van der Heide, Sicco
2007-08-01
Despite recent advances in our understanding of basophil biology and discovery of new markers for basophil activation, tests measuring basophil activation are not widely utilized in Hymenoptera allergy. Studies of the basophil-activation test in Hymenoptera allergy were examined and the clinical utility of this test was assessed. It has been demonstrated that the results of basophil-activation tests correlate quite well with those of serum IgE testing or skin-prick tests. Many studies compare test outcomes with history in patients and nonallergic controls, so that specificity in sensitized but clinically nonreactive individuals remains unknown. Although one study showed that the basophil-activation test might predict immunotherapy side effects, this could not be confirmed in a second study, and no role has been established for the basophil-activation test in the monitoring of venom immunotherapy. The basophil-activation test has no extra value in assessing sting challenges, although experience is limited. The measurement of basophil-activation markers may be useful in detecting IgE-mediated sensitization but the relevance for application of the basophil-activation test in prediction of clinical reactivity in Hymenoptera allergy is very limited. For this reason, this test currently has no established role in the diagnosis and management of patients with insect sting allergy.
From optics testing to micro optics testing
NASA Astrophysics Data System (ADS)
Brock, Christian; Dorn, Ralf; Pfund, Johannes
2017-10-01
Testing micro optics, i.e. lenses with dimensions down to 0.1mm and less, with high precision requires a dedicated design of the testing device, taking into account propagation and wave-optical effects. In this paper, we discuss testing methods based on Shack-Hartmann wavefront technology for functional testing in transmission and for the measurement of surface shape in reflection. As a first example of more conventional optics testing, i.e. optics in the millimeter range, we present the measurement of binoculars in transmission, and discuss the measured wave aberrations and imaging quality. By repeating the measurement at different wavelengths, information on chromatic effects is retrieved. A task that is often tackled using Shack-Hartman wavefront sensors is the alignment of collimation optics in front of a light source. In case of a micro-optical collimation unit with a 1/e² beam diameter of ca. 1mm, we need adapted relay optics for suitable beam expansion and well-defined imaging conditions. In this example, we will discuss the alignment process and effects of the relay optics magnification, as well as typical performance data. Oftentimes, micro optics are fabricated not as single pieces, but as mass optics, e.g. by lithographic processes. Thus, in order to reduce tooling and alignment time, an automated test procedure is necessary. We present an approach for the automated testing of wafer- or tray-based micro optics, and discuss transmission and reflection measurement capabilities. Exemplary performance data is shown for a sample type with 30 microns in diameter, where typical repeatabilities of a few nanometers (rms) are reached.
Hedlin, Gunilla; Moreno, Carmen; Petersson, Carl Johan; Lilja, Gunnar; Toledano, Félix Lorente; García, Antonio Nieto; Nordvall, Lennart; Palmqvist, Mona; Rak, Sabina; Ahlstedt, Staffan; Borres, Magnus P
2009-07-01
: Allergy is a serious problem affecting approximately 1 of 4 individuals. The symptoms with and without allergy etiology are often difficult to distinguish from each other without using an IgE antibody test. The aim of this study was to investigate the performance of a new point-of-care (POC) test for IgE antibodies to relevant allergens in Europe. : IgE antibodies from children and adults with allergies recruited from allergy clinics in Sweden and Spain were analyzed for 10 allergens, suitable for the age groups, using the new POC test and ImmunoCAP laboratory test. The IgE antibody level best discriminating between positive and negative results (the cutoff point) for the different allergens of the POC test and the efficacy of the POC and the ImmunoCAP laboratory tests for diagnosing allergy compared with that of clinical diagnosis were investigated. : The estimated cutoffs for the different allergens in the POC test ranged from 0.70 to 2.56 kUA/L. Taking into account all positive allergen results in a given patient, the POC test could identify 95% of the patients with allergies. Seventy-eight percent of the allergen-specific physicians' diagnoses were identified and 97% of the negative ones. Most allergens exhibited good performance, identifying about 80% of clinically relevant cases. However, dog, mugwort, and wall pellitory would benefit from improvement. : The POC test will be a valuable adjunct in the identification or exclusion of patients with allergies and their most likely offending allergens, both in specialist and general care settings.
Allergy Diagnosis in Children and Adults: Performance of a New Point-of-Care Device, ImmunoCAP Rapid
2009-01-01
Background Allergy is a serious problem affecting approximately 1 of 4 individuals. The symptoms with and without allergy etiology are often difficult to distinguish from each other without using an IgE antibody test. The aim of this study was to investigate the performance of a new point-of-care (POC) test for IgE antibodies to relevant allergens in Europe. Methods IgE antibodies from children and adults with allergies recruited from allergy clinics in Sweden and Spain were analyzed for 10 allergens, suitable for the age groups, using the new POC test and ImmunoCAP laboratory test. The IgE antibody level best discriminating between positive and negative results (the cutoff point) for the different allergens of the POC test and the efficacy of the POC and the ImmunoCAP laboratory tests for diagnosing allergy compared with that of clinical diagnosis were investigated. Results The estimated cutoffs for the different allergens in the POC test ranged from 0.70 to 2.56 kUA/L. Taking into account all positive allergen results in a given patient, the POC test could identify 95% of the patients with allergies. Seventy-eight percent of the allergen-specific physicians' diagnoses were identified and 97% of the negative ones. Most allergens exhibited good performance, identifying about 80% of clinically relevant cases. However, dog, mugwort, and wall pellitory would benefit from improvement. Conclusions The POC test will be a valuable adjunct in the identification or exclusion of patients with allergies and their most likely offending allergens, both in specialist and general care settings. PMID:23283063
Liquid Rocket Engine Testing Overview
NASA Technical Reports Server (NTRS)
Rahman, Shamim
2005-01-01
Contents include the following: Objectives and motivation for testing. Technology, Research and Development Test and Evaluation (RDT&E), evolutionary. Representative Liquid Rocket Engine (LRE) test compaigns. Apollo, shuttle, Expandable Launch Vehicles (ELV) propulsion. Overview of test facilities for liquid rocket engines. Boost, upper stage (sea-level and altitude). Statistics (historical) of Liquid Rocket Engine Testing. LOX/LH, LOX/RP, other development. Test project enablers: engineering tools, operations, processes, infrastructure.
Berthing mechanism final test report and program assessment
NASA Technical Reports Server (NTRS)
1988-01-01
The purpose is to document the testing performed on both hardware and software developed under the Space Station Berthing Mechanisms Program. Testing of the mechanism occurred at three locations. Several system components, e.g., actuators and computer systems, were functionally tested before assembly. A series of post assembly tests were performed. The post assembly tests, as well as the dynamic testing of the mechanism, are presented.
Feasibility Studies of an Electrochemical Test Method for Nitrogen Tetroxide Compatibility Testing.
1978-11-01
I - fl i ght Density Acid ( HDA ) type systems (N204—HNO 3) in order to achieve t r a - s - ~t i r - i h s I e d e...id rich ph a s e w i l l r e s u l t in HDA type nitric acid corrosion in localized , s i t e s ( i . - . , c r e v t s~s , s - t c . ) . E l e
DOT National Transportation Integrated Search
2015-04-01
This document is the final project technical report for the development and field testing of the Response, Emergency Staging, Communications, Uniform Management, and Evacuation (R.E.S.C.U.M.E.) application bundle, with a focus on the Incident Zone (I...
Marek, W; Marek, E; Friz, Y; Vogel, P; Mückenhoff, K; Kotschy-Lang, N
2010-03-01
AIMS OF THE INVESTIGATION: The repetition of the 6-minutes walk test (6 MWT) in older patients is frequently performed in order to document the maximal walking distance, although it is not recommended in any guidelines on exercise tests and although there is common consent to save clinical resources in terms of time and staff. Therefore, we have examined whether and to what extent the repetition of the walk tests helps patients to get more familiar with this kind of exercise test. Thus the acquired physiological data should reliably describe the physical fitness of the patients at the beginning and at the end of their clinical rehabilitation. 35 patients performed their walk tests before and after 3 - 4 weeks of clinical rehabilitation. Each test has been repeated after one hour of recovery. The patients were instructed to walk during 6 minutes as fast as possible. They were equipped with a mobile pulse oximeter for recording oxygen saturation and heart rate. The distance, S, and the heart rate, fc, were measured. Measurements were performed every 30 seconds and recorded. The efficiency, E (E = S/6/fc), was calculated as the ratio of distance per minute and the mean heart rate during the test. In the first test the patients walked 416 +/- 63 m at a heart rate of 104.7 +/- 15.7 beats/min, in the first repeated test 454 +/- 71 m at a heart of 106.3 +/- 17.4 beats/min. In the second test, after clinical therapy, they walked 438 +/- 58 m at a heart rate of 106.3 +/- 17.4 beats/min, in the second repeated test 473 +/- 56 m at 108.6 +/- 13.2/min. The difference of the walking distances of the tests at the entrance were found to be 38.4 +/- 26.2 m (+ 9.3 +/- 6.2%), at the end of clinical rehabilitation 35 +/- 26 m (+ 8.4 +/- 6.4%). Both differences are found to be independent from the distance of the first test. They are not significantly different. The efficiency was not significantly different in the initial and final test (0.673 +/- 0.129 and 0.689 +/- 0.085 m/beat, respectively). The difference in efficiency, when repeating the tests at the beginning, was: 0.053 +/- 0.062 m/beat; at the end of the rehabilitation: 0.042 +/- 0.047 m/beat. They are found to be similar. The distances the patients walked in the repeated tests at the entrance and at the end of their clinical rehabilitation were, besides the calculated efficiency, E, significantly increased. However, the increases in distance and efficiency are identical on both occasions, therefore the repetition delivers no further information. The test should be performed without repetitions in clinical routine investigations. The patient's performance in the second walk test with an unchanged distance at a lower heart rate reveals an improved physical fitness. This is solely described by an increase of efficiency, E. Therefore the introduction of E is a suitable measure of the quantified effect of exercise training, even if the patient is not cooperative during the tests. E is proved to be a suitable estimation for the assessment of physical fitness as a benefit of clinical rehabilitation. Georg Thieme Verlag KG Stuttgart, New York.
NASA Technical Reports Server (NTRS)
Domack, Marcia S.
1987-01-01
The stress corrosion behavior of the P/M aluminum alloy 7091 is evaluated in two overaged heat treatment conditions, T7E69 and T7E70, using an accelerated test technique known as the breaking load test method. The breaking load data obtained in this study indicate that P/M 7091 alloy is highly resistant to stress corrosion in both longitudinal and transverse orientations at stress levels up to 90 percent of the material yield strength. The reduction in mean breaking stress as a result of corrosive attack is smallest for the more overaged T7E70 condition. Details of the test procedure are included.
Lindström, Sara; Yen, Yu-Chun; Spiegelman, Donna; Kraft, Peter
2009-01-01
The possibility of gene-environment interaction can be exploited to identify genetic variants associated with disease using a joint test of genetic main effect and gene-environment interaction. We consider how exposure misclassification and dependence between the true exposure E and the tested genetic variant G affect this joint test in absolute terms and relative to three other tests: the marginal test (G), the standard test for multiplicative gene-environment interaction (GE), and the case-only test for interaction (GE-CO). All tests can have inflated Type I error rate when E and G are correlated in the underlying population. For the GE and G-GE tests this inflation is only noticeable when the gene-environment dependence is unusually strong; the inflation can be large for the GE-CO test even for modest correlation. The joint G-GE test has greater power than the GE test generally, and greater power than the G test when there is no genetic main effect and the measurement error is small to moderate. The joint G-GE test is an attractive test for assessing genetic association when there is limited knowledge about casual mechanisms a priori, even in the presence of misclassification in environmental exposure measurement and correlation between exposure and genetic variants. PMID:19521099
40 CFR 90.405 - Recorded information.
Code of Federal Regulations, 2014 CFR
2014-07-01
... addition to a pre- and post-test measurement. (4) Recorder chart or equivalent. Identify for each test... applicable. (e) Test data; post-test. (1) Recorder chart or equivalent. Identify the hang-up check. (2...). (4) Barometric pressure, post-test segment. [60 FR 34598, July 13, 1995, as amended at 70 FR 40449...
40 CFR 90.405 - Recorded information.
Code of Federal Regulations, 2010 CFR
2010-07-01
... addition to a pre- and post-test measurement. (4) Recorder chart or equivalent. Identify for each test... applicable. (e) Test data; post-test. (1) Recorder chart or equivalent. Identify the hang-up check. (2...). (4) Barometric pressure, post-test segment. [60 FR 34598, July 13, 1995, as amended at 70 FR 40449...
40 CFR 90.405 - Recorded information.
Code of Federal Regulations, 2011 CFR
2011-07-01
... addition to a pre- and post-test measurement. (4) Recorder chart or equivalent. Identify for each test... applicable. (e) Test data; post-test. (1) Recorder chart or equivalent. Identify the hang-up check. (2...). (4) Barometric pressure, post-test segment. [60 FR 34598, July 13, 1995, as amended at 70 FR 40449...
40 CFR 90.405 - Recorded information.
Code of Federal Regulations, 2013 CFR
2013-07-01
... addition to a pre- and post-test measurement. (4) Recorder chart or equivalent. Identify for each test... applicable. (e) Test data; post-test. (1) Recorder chart or equivalent. Identify the hang-up check. (2...). (4) Barometric pressure, post-test segment. [60 FR 34598, July 13, 1995, as amended at 70 FR 40449...
40 CFR 90.405 - Recorded information.
Code of Federal Regulations, 2012 CFR
2012-07-01
... addition to a pre- and post-test measurement. (4) Recorder chart or equivalent. Identify for each test... applicable. (e) Test data; post-test. (1) Recorder chart or equivalent. Identify the hang-up check. (2...). (4) Barometric pressure, post-test segment. [60 FR 34598, July 13, 1995, as amended at 70 FR 40449...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-17
... post-accident testing, FRA routinely conducts tests for alcohol, marijuana, cocaine, phencyclidine (PCP..., as part of its accident investigation program, FRA has conducted post-accident alcohol and drug tests... conduct post-accident tests for any substance (e.g., carbon [[Page 29308
46 CFR 16.220 - Periodic testing requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY MERCHANT MARINE OFFICERS AND SEAMEN CHEMICAL TESTING Required Chemical Testing § 16.220 Periodic testing requirements. (a) Except as provided by paragraph (c) of this section and § 10.227(e) of this chapter, an applicant must pass a chemical test for dangerous...
40 CFR 86.505-2004 - Introduction; structure of subpart.
Code of Federal Regulations, 2011 CFR
2011-07-01
... procedures and the test fuel described in subpart B of this part for diesel-fueled light-duty vehicles. PM... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.505-2004 Introduction; structure of... perform exhaust emission tests on motorcycles. Subpart E sets forth the testing requirements and test...
40 CFR 86.505-2004 - Introduction; structure of subpart.
Code of Federal Regulations, 2013 CFR
2013-07-01
... procedures and the test fuel described in subpart B of this part for diesel-fueled light-duty vehicles. PM... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.505-2004 Introduction; structure of... perform exhaust emission tests on motorcycles. Subpart E sets forth the testing requirements and test...
40 CFR 86.505-2004 - Introduction; structure of subpart.
Code of Federal Regulations, 2010 CFR
2010-07-01
... procedures and the test fuel described in subpart B of this part for diesel-fueled light-duty vehicles. PM... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.505-2004 Introduction; structure of... perform exhaust emission tests on motorcycles. Subpart E sets forth the testing requirements and test...
40 CFR 86.505-2004 - Introduction; structure of subpart.
Code of Federal Regulations, 2012 CFR
2012-07-01
... procedures and the test fuel described in subpart B of this part for diesel-fueled light-duty vehicles. PM... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.505-2004 Introduction; structure of... perform exhaust emission tests on motorcycles. Subpart E sets forth the testing requirements and test...
40 CFR 86.505-2004 - Introduction; structure of subpart.
Code of Federal Regulations, 2014 CFR
2014-07-01
... procedures and the test fuel described in subpart B of this part for diesel-fueled light-duty vehicles. PM... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.505-2004 Introduction; structure of... perform exhaust emission tests on motorcycles. Subpart E sets forth the testing requirements and test...
40 CFR 90.508 - Test procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Test procedures. 90.508 Section 90.508....508 Test procedures. (a) For nonroad engines subject to the provisions of this subpart, the prescribed test procedures are the appropriate small SI engine test procedures as described in subpart E of this...
40 CFR 89.508 - Test procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Test procedures. 89.508 Section 89.508... Test procedures. (a)(1) For nonroad engines subject to the provisions of this subpart, the prescribed test procedures are the nonroad engine 8-mode test procedure as described in subpart E of this part...
49 CFR 219.502 - Pre-employment alcohol testing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Pre-Employment Tests § 219.502 Pre... must comply with the following requirements: (1) It must conduct a pre-employment alcohol test before... the purpose of pre-employment alcohol testing (i.e., it must not test some covered employees and not...
49 CFR 219.502 - Pre-employment alcohol testing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Pre-Employment Tests § 219.502 Pre... must comply with the following requirements: (1) It must conduct a pre-employment alcohol test before... the purpose of pre-employment alcohol testing (i.e., it must not test some covered employees and not...
49 CFR 219.502 - Pre-employment alcohol testing.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Pre-Employment Tests § 219.502 Pre... must comply with the following requirements: (1) It must conduct a pre-employment alcohol test before... the purpose of pre-employment alcohol testing (i.e., it must not test some covered employees and not...
49 CFR 219.502 - Pre-employment alcohol testing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Pre-Employment Tests § 219.502 Pre... must comply with the following requirements: (1) It must conduct a pre-employment alcohol test before... the purpose of pre-employment alcohol testing (i.e., it must not test some covered employees and not...
49 CFR 219.502 - Pre-employment alcohol testing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Pre-Employment Tests § 219.502 Pre... must comply with the following requirements: (1) It must conduct a pre-employment alcohol test before... the purpose of pre-employment alcohol testing (i.e., it must not test some covered employees and not...
Department of Defense In-House RDT and E Activities
1976-10-30
BALLISTIC TESTS.FAC AVAL FCR TESIS OF SP ELELTRONIC’ FIl’ CON EQUIP 4 RELATED SYSTEMS E COMPONFNTZ, 35 INSTALLATION: MEDICAL BIOENGINEERINC- R&D LABORATORY...ANALYSIS OF CHEMICAL AND METALLOGRAPHIC EFFECTS, MICROBIOLOGICAL EFFECTS, CLIMATIC ENVIRONMENTAL EFFECTS. TEST AND EVALUATE WARHEADS AND SPECIAL...CCMMUNICATI’N SYST:M INSTRUMENTED DROP ZONES ENGINEERING TEST FACILITY INSTRUMENTATION CALIBRATICN FACILITY SCIENTIFIC COMPUTER CENTER ENVIRONMENTAL TESY
2. View looking southeast at north and west facades of ...
2. View looking southeast at north and west facades of Test Stand 'D' workshop 4222/E-23, with Test Stand 'D' tower in background and tunnel access shed to the right. Equipment on 4222/E-23 roof is for air conditioning. - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Workshop, Edwards Air Force Base, Boron, Kern County, CA
Investigating a Judgemental Rank-Ordering Method for Maintaining Standards in UK Examinations
ERIC Educational Resources Information Center
Black, Beth; Bramley, Tom
2008-01-01
A new judgemental method of equating raw scores on two tests, based on rank-ordering scripts from both tests, has been developed by Bramley. The rank-ordering method has potential application as a judgemental standard-maintaining mechanism, because given a mark on one test (e.g. the A grade boundary mark), the equivalent mark (i.e. at the same…
49 CFR 40.149 - May the MRO change a verified drug test result?
Code of Federal Regulations, 2011 CFR
2011-10-01
... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...
49 CFR 40.149 - May the MRO change a verified drug test result?
Code of Federal Regulations, 2014 CFR
2014-10-01
... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...
49 CFR 40.149 - May the MRO change a verified drug test result?
Code of Federal Regulations, 2012 CFR
2012-10-01
... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...
49 CFR 40.149 - May the MRO change a verified drug test result?
Code of Federal Regulations, 2013 CFR
2013-10-01
... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...
Norlander, Katarina; Johansson, Henrik; Jansson, Christer; Nordvall, Lennart; Nordang, Leif
2015-01-01
Surgery is an effective treatment in severe cases of supraglottic exercise-induced laryngeal obstruction (E-ILO). Conservatively treated subjects and subjects tested negative for E-ILO, who still experience breathing problems 1-3 years after diagnosis, tend to adjust their physical activity to a greater extent than surgically treated subjects. To investigate how symptoms and level of physical activity change over time in patients with E-ILO who have undergone surgery, patients with E-ILO treated conservatively and patients who tested negative for laryngeal obstruction at continuous laryngoscopy exercise-test (CLE-test). Patients referred for exercise-induced breathing difficulties answered questionnaires at diagnostic CLE-test and at follow-up. Questions regarded exercise-induced breathing problems, current physical activity level, and medical history of asthma and perennial allergy. Out of 84 invited subjects, 59 (70%) answered both questionnaires. Surgically treated subjects had less breathing problems at follow-up compared with conservatively treated subjects and subjects who tested negative (p < 0.001). None of the surgically treated subjects were less physically active or had changed sport due to exercise-induced dyspnoea, whereas 41.7% of the conservatively treated subjects had made such adjustments (p < 0.001).
12 CFR 563e.25 - Community development test for wholesale or limited purpose savings associations.
Code of Federal Regulations, 2010 CFR
2010-01-01
...). (e) Benefit to assessment area(s)—(1) Benefit inside assessment area(s). The OTS considers all... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Community development test for wholesale or limited purpose savings associations. 563e.25 Section 563e.25 Banks and Banking OFFICE OF THRIFT...
Investigating the Role of Multibiometric Authentication on Professional Certification E-Examination
ERIC Educational Resources Information Center
Smiley, Garrett
2013-01-01
E-learning has grown to such an extent that paper-based testing is being replaced by computer-based testing otherwise known as e-exams. Because these e-exams can be delivered outside of the traditional proctored environment, additional authentication measures must be employed in order to offer similar authentication assurance as found in…
Learning Factory--Integrative E-Learning
ERIC Educational Resources Information Center
Steininger, Peter
2017-01-01
Integrative E-Learning (IEP): The goal of the project is the development and testing of an integrative teaching format for the assembly of imported, tried and tested (classic) teaching elements (e.g. wallboard and flipchart, screen walls and other visualization aids, Projector, manuscripts, and workbooks, etc.), with contemporary, innovative…
Sonar Test and Test Instrumentation Support.
1979-03-29
AD-AlSO 055 TEXAS UNIV AT AUSTIN APPLIED RESEARCH LABS F/6 17/1 SONAR TEST AND TEST INSTRUMENTATION SUPPORT (U) MAR 79 0 D BAKER N00140-76-C-64a7... SONAR TEST AND TEST INSTRUMENTATION SUPPORT quarterly progress report September - 30 November 197Pj 6. PERFORMING ORG. REPORT NUMBER 7. AUTHOR(e) S...involves technical support with sonar testing, test instrumentation, and documentation. This report describes progress made under the tasks that are
Occupational asthma and IgE sensitization to grain dust.
Park, H S; Nahm, D H; Suh, C H; Kwon, O Y; Kim, K S; Lee, S W; Chung, H K
1998-06-01
To evaluate type I hypersensitivity to grain dust (GD), its prevalence and relationship to respiratory dysfunction, we studied clinical and immunologic features, including skin prick tests (SPT), serum specific IgE, and bronchoprovocation tests of 43 employees working in the animal feed industry. To further characterize IgE-mediated reaction, SDS-PAGE and electroblot studies were performed. Our survey revealed that 15 (34.9%) subjects had work-related skin response (> or =2+ of A/H ratio) to GD, thirteen (30.2%) had high specific IgE antibody against GD. The specific IgE antibody was detected more frequently in symptomatic workers (40%) than in asymptomatic workers (11%). Significant association was found between specific IgE antibody and atopy or smoking (p<0.05). The ELISA inhibition test of GD revealed significant inhibitions by GD extract and minimal inhibitions by the house dust mite, storage mite and corn dust. Immunoblot analysis showed 8 IgE binding components within GD ranging from 13.5 to 142.5 kDa. Two bands (13.5, 33 kDa) were bound to the IgE from more than 50% of the 14 sera tested. In conclusion, these findings suggest that GD inhalation could induce IgE-mediated bronchoconstriction in exposed workers.
Liu, Hong-cui; Yuan, Bing-qiang; Li, Shao-nan
2016-02-01
To yield cholinesterase (ChE) from prokaryotic expression, the ChE gene that belongs to Daphnia magna was amplified by reverse transcription-polymerase chain reaction (RT-PCR) using forward primer 5'-CCCYGGNGCSAT GATGTG-3' and reverse primer 5'-GYAAGTTRGCCCAATATCT-3'. To express the gene, one sequence of the amplified DNA, which was able to encode a putative protein containing two conserved carboxylesterase domains, was connected to the prokaryotic expression vector PET-29a(+). The recombinant vector was transformed into Escherichia coil BL21 (DE3). Protein expression was induced by isopropy-D-thiogalactoside. The expressed ChE was used as an immunogen to immunize BALB/c mice. The obtained antibodies were tested for their specificity towards crude enzymes from species such as Alona milleri, Macrobrachium nipponense, Bombyx mori, Chironomus kiiensis, Apis mellifera, Eisenia foetida, Brachydanio rerio, and Xenopus laevis. Results indicated that the antibodies had specificity suitable for detecting ChE in Daphnia magna. A type of indirect and non-competitive enzyme-linked immunosorbent assay (IN-ELISA) was used to test the immunoreactive content of ChE (ChE-IR) in Daphina magna. The detection limit of the IN-ELISA was found to be 14.5 ng/ml at an antiserum dilution of 1:22 000. Results from tests on Daphnia magna exposed to sublethal concentrations of triazophos indicated a maximal induction of 57.2% in terms of ChE-IR on the second day after the animals were exposed to a concentration of 2.10 μg/L triazophos. Testing on animals acclimatized to a temperature of 16 °C indicated that ChE-IR was induced by 16.9% compared with the ChE-IR content detected at 21 °C, and the rate of induction was 25.6% at 10 °C. The IN-ELISA was also used to test the stability of ChE-IR in collected samples. Repeated freezing and thawing had no influence on the outcome of the test. All these results suggest that the polyclonal antibodies developed against the recombinant ChE are as efficient as those developed against the native ChE in detecting ChE content in Daphnia magna.
Liu, Hong-cui; Yuan, Bing-qiang; Li, Shao-nan
2016-01-01
To yield cholinesterase (ChE) from prokaryotic expression, the ChE gene that belongs to Daphnia magna was amplified by reverse transcription-polymerase chain reaction (RT-PCR) using forward primer 5'-CCCYGGNGCSAT GATGTG-3' and reverse primer 5'-GYAAGTTRGCCCAATATCT-3'. To express the gene, one sequence of the amplified DNA, which was able to encode a putative protein containing two conserved carboxylesterase domains, was connected to the prokaryotic expression vector PET-29a(+). The recombinant vector was transformed into Escherichia coil BL21 (DE3). Protein expression was induced by isopropy-D-thiogalactoside. The expressed ChE was used as an immunogen to immunize BALB/c mice. The obtained antibodies were tested for their specificity towards crude enzymes from species such as Alona milleri, Macrobrachium nipponense, Bombyx mori, Chironomus kiiensis, Apis mellifera, Eisenia foetida, Brachydanio rerio, and Xenopus laevis. Results indicated that the antibodies had specificity suitable for detecting ChE in Daphnia magna. A type of indirect and non-competitive enzyme-linked immunosorbent assay (IN-ELISA) was used to test the immunoreactive content of ChE (ChE-IR) in Daphina magna. The detection limit of the IN-ELISA was found to be 14.5 ng/ml at an antiserum dilution of 1:22 000. Results from tests on Daphnia magna exposed to sublethal concentrations of triazophos indicated a maximal induction of 57.2% in terms of ChE-IR on the second day after the animals were exposed to a concentration of 2.10 μg/L triazophos. Testing on animals acclimatized to a temperature of 16 °C indicated that ChE-IR was induced by 16.9% compared with the ChE-IR content detected at 21 °C, and the rate of induction was 25.6% at 10 °C. The IN-ELISA was also used to test the stability of ChE-IR in collected samples. Repeated freezing and thawing had no influence on the outcome of the test. All these results suggest that the polyclonal antibodies developed against the recombinant ChE are as efficient as those developed against the native ChE in detecting ChE content in Daphnia magna. PMID:26834012
Jaarsveld, Saskia; Lachmann, Thomas
2017-01-01
This paper discusses the importance of three features of psychometric tests for cognition research: construct definition, problem space, and knowledge domain. Definition of constructs, e.g., intelligence or creativity, forms the theoretical basis for test construction. Problem space, being well or ill-defined, is determined by the cognitive abilities considered to belong to the constructs, e.g., convergent thinking to intelligence, divergent thinking to creativity. Knowledge domain and the possibilities it offers cognition are reflected in test results. We argue that (a) comparing results of tests with different problem spaces is more informative when cognition operates in both tests on an identical knowledge domain, and (b) intertwining of abilities related to both constructs can only be expected in tests developed to instigate such a process. Test features should guarantee that abilities can contribute to self-generated and goal-directed processes bringing forth solutions that are both new and applicable. We propose and discuss a test example that was developed to address these issues. PMID:28220098
Manipulating Objects and Telling Words: A Study on Concrete and Abstract Words Acquisition
Borghi, Anna M.; Flumini, Andrea; Cimatti, Felice; Marocco, Davide; Scorolli, Claudia
2011-01-01
Four experiments (E1–E2–E3–E4) investigated whether different acquisition modalities lead to the emergence of differences typically found between concrete and abstract words, as argued by the words as tools (WAT) proposal. To mimic the acquisition of concrete and abstract concepts, participants either manipulated novel objects or observed groups of objects interacting in novel ways (Training 1). In TEST 1 participants decided whether two elements belonged to the same category. Later they read the category labels (Training 2); labels could be accompanied by an explanation of their meaning. Then participants observed previously seen exemplars and other elements, and were asked which of them could be named with a given label (TEST 2). Across the experiments, it was more difficult to form abstract than concrete categories (TEST 1); even when adding labels, abstract words remained more difficult than concrete words (TEST 2). TEST 3 differed across the experiments. In E1 participants performed a feature production task. Crucially, the associations produced with the novel words reflected the pattern evoked by existing concrete and abstract words, as the first evoked more perceptual properties. In E2–E3–E4, TEST 3 consisted of a color verification task with manual/verbal (keyboard–microphone) responses. Results showed the microphone use to have an advantage over keyboard use for abstract words, especially in the explanation condition. This supports WAT: due to their acquisition modality, concrete words evoke more manual information; abstract words elicit more verbal information. This advantage was not present when linguistic information contrasted with perceptual one. Implications for theories and computational models of language grounding are discussed. PMID:21716582
In vitro evaluation of antimicrobial features of sugammadex.
Hanci, Volkan; Vural, Ahmet; Hanci, Sevgi Yılmaz; Ali Kiraz, Hasan; Omür, Dilek; Unver, Ahmet
2014-01-01
Drugs administered by intravenous routes may be contaminated during several stages of production or preparation. Sugammadex is a modified gamma cyclodextrin. While research into the antibacterial effects of varieties of cyclodextrin is available, there are no studies focusing on the antibacterial effects of sugammadex. This study investigates the in vitro antimicrobial activity of sugammadex. The in vitro antimicrobial activity of sugammadex was investigated using the broth microdilution method. The pH of the test solution was determined using a pH meter. The test microorganisms included Staphylococcus aureus ATCC 29213, Enterococcus fecalis ATCC 29212, Escherichia coli ATCC 25922 and Pseudomonas aeruginosa ATCC 27853. In the second phase of the study 100mg/mL sugammadex (50μg) was contaminated with test microorganisms (50μg), including S. aureus ATCC 29213, E. fecalis ATCC 29212, E. coli ATCC 25922 and P. aeruginosa ATCC 27853, left to incubate for 24h and then the bacterial production in sugammadex was evaluated. The pH of the test solutions ranged between 7.25 and 6.97. Using the microdilution method, sugammadex had no antibacterial effect on S. aureus, E. fecalis, E. coli and P. aeruginosa at any concentration. In the second phase of the study bacterial production was observed after 24h in 100mg/mL sugammadex contaminated with the test microorganisms S. aureus, E. fecalis, E. coli and P. aeruginosa. Sugammadex had no antimicrobial effect on the test microorganisms, S. aureus, E. fecalis, E. coli and P. aeruginosa. Care should be taken that sterile conditions are maintained in the preparation of sugammadex; that the same sugammadex preparation not be used for more than one patient; and that storage conditions are adhered to after sugammadex is put into the injector. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Relationship between strength, power and balance performance in seniors.
Muehlbauer, Thomas; Besemer, Carmen; Wehrle, Anja; Gollhofer, Albert; Granacher, Urs
2012-01-01
Deficits in strength, power and balance represent important intrinsic risk factors for falls in seniors. The purpose of this study was to investigate the relationship between variables of lower extremity muscle strength/power and balance, assessed under various task conditions. Twenty-four healthy and physically active older adults (mean age: 70 ± 5 years) were tested for their isometric strength (i.e. maximal isometric force of the leg extensors) and muscle power (i.e. countermovement jump height and power) as well as for their steady-state (i.e. unperturbed standing, 10-meter walk), proactive (i.e. Timed Up & Go test, Functional Reach Test) and reactive (i.e. perturbed standing) balance. Balance tests were conducted under single (i.e. standing or walking alone) and dual task conditions (i.e. standing or walking plus cognitive and motor interference task). Significant positive correlations were found between measures of isometric strength and muscle power of the lower extremities (r values ranged between 0.608 and 0.720, p < 0.01). Hardly any significant associations were found between variables of strength, power and balance (i.e. no significant association in 20 out of 21 cases). Additionally, no significant correlations were found between measures of steady-state, proactive and reactive balance or balance tests performed under single and dual task conditions (all p > 0.05). The predominately nonsignificant correlations between different types of balance imply that balance performance is task specific in healthy and physically active seniors. Further, strength, power and balance as well as balance under single and dual task conditions seem to be independent of each other and may have to be tested and trained complementarily. Copyright © 2012 S. Karger AG, Basel.
Regional and depth variability of porcine meniscal mechanical properties through biaxial testing.
Kahlon, A; Hurtig, M B; Gordon, K D
2015-01-01
The menisci in the knee joint undergo complex loading in-vivo resulting in a multidirectional stress distribution. Extensive mechanical testing has been conducted to investigate the tissue properties of the knee meniscus, but the testing conditions do not replicate this complex loading regime. Biaxial testing involves loading tissue along two different directions simultaneously, which more accurately simulates physiologic loading conditions. The purpose of this study was to report mechanical properties of meniscal tissue resulting from biaxial testing, while simultaneously investigating regional variations in properties. Ten left, fresh porcine joints were obtained, and the medial and lateral menisci were harvested from each joint (twenty menisci total). Each menisci was divided into an anterior, middle and posterior region; and three slices (femoral, deep and tibial layers) were obtained from each region. Biaxial and constrained uniaxial testing was performed on each specimen, and Young's moduli were calculated from the resulting stress strain curves. Results illustrated significant differences in regional mechanical properties, with the medial anterior (Young's modulus (E)=11.14 ± 1.10 MPa), lateral anterior (E=11.54 ± 1.10 MPa) and lateral posterior (E=9.0 ± 1.2 MPa) regions exhibiting the highest properties compared to the medial central (E=5.0 ± 1.22 MPa), medial posterior (E=4.16 ± 1.13 MPa) and lateral central (E=5.6 ± 1.20 MPa) regions. Differences with depth were also significant on the lateral meniscus, with the femoral (E=12.7 ± 1.22 MPa) and tibial (E=8.6 ± 1.22 MPa) layers exhibiting the highest Young's moduli. This data may form the basis for future modeling of meniscal tissue, or may aid in the design of synthetic replacement alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.
Rosa, Jessica; Myskiw, Jociane C; Furini, Cristiane R G; Sapiras, Gerson G; Izquierdo, Ivan
2014-09-01
We investigate whether the extinction of inhibitory avoidance (IA) learning can be subjected to endogenous state-dependence with systemic injections of epinephrine (E), and whether endogenous norepinephrine (NE) and the nucleus tractus solitarius (NTS)→locus coeruleus→hippocampus/amygdala (HIPP/BLA) pathway participate in this. Rats trained in IA were submitted to two sessions of extinction 24 h apart: In the first, the animals were submitted to a training session of extinction, and in the second they were tested for the retention of extinction. Saline or E were given i.p. immediately after the extinction training (post-extinction training injections) and/or 6 min before the extinction test (pre-extinction test). Post-extinction training E (50 or 100 μg/kg) induced a poor retrieval of extinction in the test session of this task unless an additional E injection (50 μg/kg) was given prior to the extinction test. This suggested state-dependence. Muscimol (0.01 μg/side) microinfused into the NTS prior to the extinction test session blocked E-induced state-dependence. Norepinephrine (NE, 1 μg/side) infused bilaterally into NTS restores the extinction impairment caused by post-extinction training i.p. E. In animals with bilateral NTS blockade induced by muscimol, NE (1 μg/side) given prior to the extinction test into the CA1 region of the dorsal hippocampus or into the basolateral amygdala restored the normal extinction levels that had been impaired by muscimol. These results suggest a role for the NTS→locus coeruleus→HIPP/BLA pathway in the retrieval of extinction, as it has been shown to have in the consolidation of inhibitory avoidance and of object recognition learning. Copyright © 2013 Elsevier Inc. All rights reserved.
TOP 01-1-011B Vehicle Test Facilities at Aberdeen Test Center and Yuma Test Center
2017-12-12
TYPE Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Test Operations Procedure (TOP) 01-1-011B Vehicle Test Facilities at Aberdeen... Test Center and Yuma Test Center 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHORS 5d. PROJECT NUMBER 5e... Test Center 400 Colleran Road Aberdeen Proving Ground, MD 21005-5059 U.S. Army Yuma Proving Ground Yuma Test Center 301 C. Street Yuma, AZ
2012-08-16
Two large-engine tests were conducted simultaneously for the first time at Stennis Space Center on Aug. 16. A plume on the left indicates a test on the facility's E-1 Test Stand. On the right, a finger of fire indicates a test under way on the A-1 Test Stand. In another first, both tests were conducted by female engineers. The image was taken from atop the facility's A-2 Test Stand, offering a panoramic view that includes the new A-3 Test Stand under construction to the left.
Viability of gait speed test in hospitalized elderly patients.
Martinez, Bruno Prata; Batista, Anne Karine Menezes Santos; Ramos, Isis Resende; Dantas, Júlio Cesar; Gomes, Isabela Barboza; Forgiarini, Luiz Alberto; Camelier, Fernanda Rosa Warken; Camelier, Aquiles Assunção
2016-01-01
The gait speed test (GST) is a physical test that can predict falls and aid in the diagnosis of sarcopenia in the elderly. However, to our knowledge, there have been no studies evaluating its reproducibility in hospitalized elderly patients. The objective of this study was to evaluate the safety and reproducibility of the six-meter GST (6GST) in hospitalized elderly patients. This repeated measures study involved hospitalized elderly patients (≥ 60 years of age) who underwent the 6GST by the fifth day of hospitalization, were able to walk without assistance, and presented no signs of dyspnea or pain that would prevent them from performing the test. The 6GST was performed three times in sequence, with a rest period between each test, in a level corridor. Gait speed was measured in meters/second. Reproducibility was assessed by comparing the means, intraclass correlation coefficients (ICCs) and Bland-Altman plots. We evaluated 110 elderly patients in a total of 330 tests. All participants completed all of the tests. The comparisons between the speeds obtained during the three tests showed high ICCs and a low mean bias (Bland-Altman plots). The correlation and accuracy were greatest when the mean maximum speed was compared with that obtained in the third test (1.26 ± 0.44 m/s vs. 1.22 ± 0.44 m/s; ICC = 0.99; p = 0.001; mean bias = 0.04; and limits of agreement = -0.27 to 0.15). The 6GST was proven to be safe and to have good reproducibility in this sample of hospitalized elderly patients. The third measurement seems to correspond to the maximum speed, since the first two measurements underestimated the actual performance. O teste de velocidade de marcha (TVM) é um teste físico que pode predizer quedas e auxiliar no diagnóstico de sarcopenia em idosos da comunidade. Entretanto, pelo que sabemos, não há estudos que avaliaram sua reprodutibilidade em idosos hospitalizados. O objetivo deste estudo foi avaliar a segurança e a reprodutibilidade do TVM de seis metros (TVM6) em idosos hospitalizados. Estudo com medidas repetidas envolvendo idosos hospitalizados (idade ≥ 60 anos) que realizaram o TVM6 até o quinto dia de hospitalização, sendo capazes de andar sem auxílio e não apresentando dispneia ou dor que os incapacitasse para a realização dos testes. O TVM6 foi realizado sequencialmente três vezes, com período de descanso, em um corredor plano, e a velocidade de marcha foi calculada em metros/segundo. A reprodutibilidade foi avaliada pela comparação das médias, coeficientes de correlação intraclasse (CCI) e disposições gráficas de Bland-Altman. Foram avaliados 110 idosos avaliados com um total de 330 testes. Todos os participantes completaram todos os testes. As comparações entre as velocidades obtidas nos três testes realizados indicaram CCIs elevados e viés médio baixo pela disposição gráfica de Bland-Altman. Em relação à maior velocidade aferida, a correlação e a precisão foram maiores quando comparadas à obtida no terceiro teste (1,26 ± 0,44 m/s vs. 1,22 ± 0,44 m/s; CCI = 0,99; p = 0,001; viés médio = 0,04; e limites de concordância = -0,27 a 0,15). O TVM6 mostrou-se seguro e teve boa reprodutibilidade nessa amostra de idosos hospitalizados. A terceira aferição parece corresponder à velocidade máxima, já que duas primeiras subestimaram o desempenho real.
Boursier, Jérôme; de Ledinghen, Victor; Leroy, Vincent; Anty, Rodolphe; Francque, Sven; Salmon, Dominique; Lannes, Adrien; Bertrais, Sandrine; Oberti, Frederic; Fouchard-Hubert, Isabelle; Calès, Paul
2017-06-01
Chronic liver diseases (CLD) are common, and are therefore mainly managed by non-hepatologists. These physicians lack access to the best non-invasive tests of liver fibrosis, and consequently cannot accurately determine the disease severity. Referral to a hepatologist is then needed. We aimed to implement an algorithm, comprising a new first-line test usable by all physicians, for the detection of advanced liver fibrosis in all CLD patients. Diagnostic study: 3754 CLD patients with liver biopsy were 2:1 randomized into derivation and validation sets. Prognostic study: longitudinal follow-up of 1275 CLD patients with baseline fibrosis tests. Diagnostic study: the easy liver fibrosis test (eLIFT), an "at-a-glance" sum of points attributed to age, gender, gamma-glutamyl transferase, aspartate aminotransferase (AST), platelets and prothrombin time, was developed for the diagnosis of advanced fibrosis. In the validation set, eLIFT and fibrosis-4 (FIB4) had the same sensitivity (78.0% vs. 76.6%, p=0.470) but eLIFT gave fewer false positive results, especially in patients ≥60years old (53.8% vs. 82.0%, p<0.001), and was thus more suitable as screening test. FibroMeter with vibration controlled transient elastography (VCTE) was the most accurate among the eight fibrosis tests evaluated. The sensitivity of the eLIFT-FM VCTE algorithm (first-line eLIFT, second-line FibroMeter VCTE ) was 76.1% for advanced fibrosis and 92.1% for cirrhosis. Prognostic study: patients diagnosed as having "no/mild fibrosis" by the algorithm had excellent liver-related prognosis with thus no need for referral to a hepatologist. The eLIFT-FM VCTE algorithm extends the detection of advanced liver fibrosis to all CLD patients and reduces unnecessary referrals of patients without significant CLD to hepatologists. Blood fibrosis tests and transient elastography accurately diagnose advanced liver fibrosis in the large population of patients having chronic liver disease, but these non-invasive tests are only currently available in specialized centers. We have developed an algorithm including the easy liver fibrosis test (eLIFT), a new simple and widely available blood test. It is used as a first-line procedure that selects at-risk patients who need further evaluation with the FibroMeter VCTE , an accurate fibrosis test combining blood markers and transient elastography result. This new algorithm, called the eLIFT-FM VCTE , accurately identifies the patients with advanced chronic liver disease who need referral to a specialist, and those with no or mild liver lesions who can remain under the care of their usual physician. No registration (analysis of pooled data from previously published diagnostic studies). Copyright © 2017 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
Anderson, Steven; Bloom, Kenneth J; Vallera, Dino U; Rueschoff, Josef; Meldrum, Cliff; Schilling, Robert; Kovach, Barbara; Lee, Ju Ruey-Jiuan; Ochoa, Pam; Langland, Rachel; Halait, Harkanwal; Lawrence, H Jeffrey; Dugan, Michael C
2012-11-01
A polymerase chain reaction-based companion diagnostic (cobas 4800 BRAF V600 Mutation Test) was recently approved by the US Food and Drug Administration to select patients with BRAF-mutant metastatic melanoma for treatment with the BRAF inhibitor vemurafenib. (1) To compare the analytic performance of the cobas test to Sanger sequencing by using screening specimens from phase II and phase III trials of vemurafenib, and (2) to assess the reproducibility of the cobas test at different testing sites. Specimens from 477 patients were used to determine positive and negative percent agreements between the cobas test and Sanger sequencing for detecting V600E (1799T>A) mutations. Specimens were evaluated with a massively parallel pyrosequencing method (454) to resolve discordances between polymerase chain reaction and Sanger results. Reproducibility of the cobas test was assessed at 3 sites by using 3 reagent lots and an 8-member panel of melanoma samples. A valid cobas result was obtained for all eligible patients. Sanger sequencing had a failure rate of 9.2% (44 of 477). For the remaining 433 specimens, positive percent agreement was 96.4% (215 of 223) and negative percent agreement, 80% (168 of 210). Among 42 cobas mutation-positive/Sanger V600E-negative specimens, 17 were V600E positive and 24 were V600K positive by 454. The cobas test detected 70% of V600K mutations. In the reproducibility study, a correct interpretation was made for 100% of wild-type specimens and specimens with greater than 5% mutant alleles; V600E mutations were detected in 90% of specimens with less than 5% mutant alleles. The cobas test (1) had a lower assay failure rate than that of Sanger, (2) was more sensitive in detecting V600E mutations, (3) detected most V600K mutations, and (4) was highly reproducible.
NASA Technical Reports Server (NTRS)
Lowry, D. W.; Rich, M. J.
1983-01-01
The installation of a composite skin panel on the cargo ramp of a CH-530 marine helicopter is discussed. The composite material is of Kevlar/Epoxy (K/E) which replaces aluminum outer skins on the aft two bays of the ramp. The cargo ramp aft region was selected as being a helicopter airframe surface subjected to possible significant field damage and would permit an evaluation of the long term durability of the composite skin panel. A structural analysis was performed and the skin shears determined. Single lap joints of K/E riveted to aluminum were statically tested. The joint tests were used to determine bearing allowables and the required K/E skin gage. The K/E skin panels riveted to aluminum edge members were tested in a shear fixture to confirm the allowable shear and bearing strengths. Impact tests were conducted on aluminum skin panels to determine energy level and damage relationship. The K/E skin panels of various ply orientations and laminate thicknesses were then impacted at similar energy levels. The results of the analysis and tests were used to determine the required K/E skin gages in each of the end two bays of the ramp.
Luttmer, Roosmarijn; Berkhof, Johannes; Dijkstra, Maaike G; van Kemenade, Folkert J; Snijders, Peter J F; Heideman, Daniëlle A M; Meijer, Chris J L M
2015-06-01
High-risk human papillomavirus (hrHPV) DNA positive women require triage testing to identify those with high-grade cervical intraepithelial neoplasia or cancer (≥CIN2). Comparing three triage algorithms (1) E7 mRNA testing following HPV16/18/31/33/45/52/58 genotyping (E7 mRNA test), (2) HPV16/18 DNA genotyping and (3) cytology, for ≥CIN2 detection in hrHPV DNA-positive women. hrHPV DNA-positive women aged 18-63 years visiting gynecology outpatient clinics were included in a prospective observational cohort study. From these women a cervical scrape and colposcopy-directed biopsies were obtained. Cervical scrapes were evaluated by cytology, HPV DNA genotyping by bead-based multiplex genotyping of GP5+6+-PCR-products, and presence of HPV16/18/31/33/45/52/58 E7 mRNA using nucleic acid sequence-based amplification (NASBA) in DNA positive women for respective HPV types. Sensitivities and specificities for ≥CIN2 were compared between E7 mRNA test and HPV16/18 DNA genotyping in the total group (n=348), and E7 mRNA test and cytology in a subgroup of women referred for non-cervix-related gynecological complaints (n=133). Sensitivity for ≥CIN2 of the E7 mRNA test was slightly higher than that of HPV16/18 DNA genotyping (66.9% versus 60.9%; ratio 1.10, 95% CI: 1.0002-1.21), at similar specificity (54.8% versus 52.3%; ratio 1.05, 95% CI: 0.93-1.18). Neither sensitivity nor specificity of the E7 mRNA test differed significantly from that of cytology (sensitivity: 68.8% versus 75.0%; ratio 0.92, 95% CI: 0.72-1.17; specificity: 59.4% versus 65.3%; ratio 0.91, 95% CI: 0.75-1.10). For detection of ≥CIN2 in hrHPV DNA-positive women, an algorithm including E7 mRNA testing following HPV16/18/31/33/45/52/58 DNA genotyping performs similar to HPV16/18 DNA genotyping or cytology. Copyright © 2015 Elsevier B.V. All rights reserved.
Radio astronomy interferometer network testing for a Malaysia-China real-time e-VLBI
NASA Astrophysics Data System (ADS)
Abidin, Zamri Zainal; Hashim, Shaiful Jahari; Wei, Lim Yang; Zhong, Chen; Rosli, Zulfazli
2018-01-01
The uv-coverage of the current VLBI network between Australia northern Asia will be significantly enhanced with an existence of a middle baseline VLBI station located in Malaysia. This paper investigated the connecting route of the first half of the Asia-Oceania VLBI network i.e. from Malaysia to China. The investigation of transmission network characteristics between Malaysia and China was carried out in order to perform a real-time and reliable data transfer within the e-VLBI network for future eVLBI observations. MyREN (Malaysia) and CSTNET (China) high-speed research networks were utilized for this proposed e-VLBI connection. Preliminary network test was performed by ping, traceroute, and iperf prior to data transfer tests, which were evaluated with three types of protocols namely FTP, Tsunami-UDT and UDT. The results showed that, on average, there were eighteen hops between Malaysia and China networks with 98 ms round trip time (RTT) delay. Overall UDP protocol has a better throughput compared to TCP protocol. UDP can reach a maximum rate of 90 Mbps with 0% packet loss. In this feasibility test, the VLBI test data was successfully transferred between Malaysia and China by utilizing the three types of data transfer protocols.
[Evaluation of the new ImmunoCard STAT!® CGE test for the diagnosis of Amebiasis].
Formenti, F; Perandin, F; Bonafini, S; Degani, M; Bisoffi, Z
2015-08-01
For many years, microscopic examination of stool samples has been considered to be the "gold standard" for diagnosis of intestinal parasites although the Polymerase Chain Reaction (PCR) analysis is increasingly utilized due to its high accuracy. Recently, PCR has been approved by the World Health Organization as the current method of choice for the diagnosis of Entamoeba histolytica infection. In this study we evaluated a novel immunochromatographic antigen detection rapid test, ImmunoCardSTAT CGE (Meridian Bioscence, Milan, Italy), which has been proposed for the diagnosis of infections caused by Cryptosporidium parvum-Giardia intestinalis-Entamoeba histolytica. There is another rapid test with a similar name, the ImmunoCard STAT! Crypto/Giardia, but it is just for Cryptosporidium and Giardia. We aimed to compare E. histolytica results obtained from the rapid test with those of a rt-PCR for the detection of E. histolytica / E. dispar DNA. The new ImmunoCard rapid antigen detection test exhibited 88% sensitivity and 92% specificity (if assessed on rt-PCR negative samples) but showed a high proportion of cross-reaction between the pathogenic E. histolytica and the non pathogenic E. dispar.
Digital Divide Measurement in Lembata Regency Using SIBIS
NASA Astrophysics Data System (ADS)
Gabriel, Cecilia Dai Payon Binti; Setyohadi, Djoko Budiyanto; Suyoto
2018-02-01
Along with technological development in Indonesia, digital divide occurs in various regions, which were behind in terms of information on how to use, access and utilize ICT in collecting information from internet. One of the regions is Lembata Regency in East Nusa Tenggara, where digital divide among the people should be measured. The purpose of this study was to determine the level of digital divide among the people of Lembata Regency. To determine the level of digital divide, we used SIBIS GPS (General Population Survey) method, which consisted of several indicators or aspect, i.e. internet usage behavior, internet utilization, and e-government. We also performed two tests, i.e. validity test and reliability test to obtain value of index of digital divide measurement among the people of Lembata Regency. The results of validity test which is processed using SPSS program are categorized valid for each variable indicator and the reliability test results show reliable status. According to the test results on digital discrepancy in Lembata people, the internet usage attitude indicator is categorized low which is 63.1%, the internet usage function indicator is categorized low which is 64%, and the digital discrepancy of e-government indicator is categorized medium which is 40.4%. Therefore, the result of this study because consideration for the government of Lembata Regency in improving ICT services in e-government and in distributing ICT access and ability equally to the people.
kruX: matrix-based non-parametric eQTL discovery
2014-01-01
Background The Kruskal-Wallis test is a popular non-parametric statistical test for identifying expression quantitative trait loci (eQTLs) from genome-wide data due to its robustness against variations in the underlying genetic model and expression trait distribution, but testing billions of marker-trait combinations one-by-one can become computationally prohibitive. Results We developed kruX, an algorithm implemented in Matlab, Python and R that uses matrix multiplications to simultaneously calculate the Kruskal-Wallis test statistic for several millions of marker-trait combinations at once. KruX is more than ten thousand times faster than computing associations one-by-one on a typical human dataset. We used kruX and a dataset of more than 500k SNPs and 20k expression traits measured in 102 human blood samples to compare eQTLs detected by the Kruskal-Wallis test to eQTLs detected by the parametric ANOVA and linear model methods. We found that the Kruskal-Wallis test is more robust against data outliers and heterogeneous genotype group sizes and detects a higher proportion of non-linear associations, but is more conservative for calling additive linear associations. Conclusion kruX enables the use of robust non-parametric methods for massive eQTL mapping without the need for a high-performance computing infrastructure and is freely available from http://krux.googlecode.com. PMID:24423115
2011-01-01
Background The botanical relation between grass and cereal grains may be relevant when diagnosing food allergy to cereals. The aim was to investigate the diagnostic specificity of skin prick test (SPT) and specific immunoglobulin E (sIgE) tests to cereals and peanut in grass pollen allergic subjects without history of, and clinically reactions to foods botanically related to grass. Methods 70 subjects (41 females; mean age 32 years) and 20 healthy controls (13 females; mean age 24 years) were tested by open food challenge (OFC) with cereals and peanut. SPT and sIgE both with Immulite® (Siemens) and ImmunoCAP® (Phadia) to grass and birch pollen, cereals, peanut and bromelain were performed. Results Of the 65 OFC-negative subjects 29-46% (SPT, depending on cut-off), 20% (Immulite) and 38% (ImmunoCAP) had positive results to one or more of the foods tested. Controls were negative in all tests. Cross-reactive carbohydrate determinants (CCD) as evidenced by reaction to bromelain could explain only a minority of the measured IgE-sensitizations. Conclusion Grass pollen allergic patients with documented food tolerance to cereals and peanut may express significant sensitization. False-positive cereal or peanut allergy diagnoses may be a quantitatively important problem both in routine clinical work and epidemiological studies. PMID:22409998
Gschwind, Yves J; Kressig, Reto W; Lacroix, Andre; Muehlbauer, Thomas; Pfenninger, Barbara; Granacher, Urs
2013-10-09
With increasing age neuromuscular deficits (e.g., sarcopenia) may result in impaired physical performance and an increased risk for falls. Prominent intrinsic fall-risk factors are age-related decreases in balance and strength / power performance as well as cognitive decline. Additional studies are needed to develop specifically tailored exercise programs for older adults that can easily be implemented into clinical practice. Thus, the objective of the present trial is to assess the effects of a fall prevention program that was developed by an interdisciplinary expert panel on measures of balance, strength / power, body composition, cognition, psychosocial well-being, and falls self-efficacy in healthy older adults. Additionally, the time-related effects of detraining are tested. Healthy old people (n = 54) between the age of 65 to 80 years will participate in this trial. The testing protocol comprises tests for the assessment of static / dynamic steady-state balance (i.e., Sharpened Romberg Test, instrumented gait analysis), proactive balance (i.e., Functional Reach Test; Timed Up and Go Test), reactive balance (i.e., perturbation test during bipedal stance; Push and Release Test), strength (i.e., hand grip strength test; Chair Stand Test), and power (i.e., Stair Climb Power Test; countermovement jump). Further, body composition will be analysed using a bioelectrical impedance analysis system. In addition, questionnaires for the assessment of psychosocial (i.e., World Health Organisation Quality of Life Assessment-Bref), cognitive (i.e., Mini Mental State Examination), and fall risk determinants (i.e., Fall Efficacy Scale - International) will be included in the study protocol. Participants will be randomized into two intervention groups or the control / waiting group. After baseline measures, participants in the intervention groups will conduct a 12-week balance and strength / power exercise intervention 3 times per week, with each training session lasting 30 min. (actual training time). One intervention group will complete an extensive supervised training program, while the other intervention group will complete a short version ('3 times 3') that is home-based and controlled by weekly phone calls. Post-tests will be conducted right after the intervention period. Additionally, detraining effects will be measured 12 weeks after program cessation. The control group / waiting group will not participate in any specific intervention during the experimental period, but will receive the extensive supervised program after the experimental period. It is expected that particularly the supervised combination of balance and strength / power training will improve performance in variables of balance, strength / power, body composition, cognitive function, psychosocial well-being, and falls self-efficacy of older adults. In addition, information regarding fall risk assessment, dose-response-relations, detraining effects, and supervision of training will be provided. Further, training-induced health-relevant changes, such as improved performance in activities of daily living, cognitive function, and quality of life, as well as a reduced risk for falls may help to lower costs in the health care system. Finally, practitioners, therapists, and instructors will be provided with a scientifically evaluated feasible, safe, and easy-to-administer exercise program for fall prevention.
Schermer, Tjard R; Akkermans, Reinier P; Crockett, Alan J; van Montfort, Marian; Grootens-Stekelenburg, Joke; Stout, Jim W; Pieters, Willem
2011-01-01
Spirometry has become an indispensable tool in primary care to exclude, diagnose, and monitor chronic respiratory conditions, but the quality of spirometry tests in family practices is a reason for concern. Aim of this study was to investigate whether a combination of e-learning and bimonthly performance feedback would improve spirometry test quality in family practices in the course of 1 year. Our study was a cluster trial with 19 family practices allocated to intervention or control conditions through minimization. Intervention consisted of e-learning and bimonthly feedback reports to practice nurses. Control practices received only the joint baseline workshop. Spirometry quality was assessed by independent lung function technicians. Two outcomes were defined, with the difference between rates of tests with 2 acceptable and repeatable blows being the primary outcome and the difference between rates of tests with 2 acceptable blows being the secondary outcome. We used multilevel logistic regression analysis to calculate odds ratios (ORs) for an adequate test in intervention group practices. We analyzed 1,135 tests. Rate of adequate tests was 33% in intervention and 30% in control group practices (OR = 1.3; P=.605). Adequacy of tests did not differ between groups but tended to increase with time: OR = 2.2 (P = .057) after 3 and OR = 2.0 (P = .086) in intervention group practices after 4 feedback reports. When ignoring test repeatability, these differences between the groups were slightly more pronounced: OR = 2.4 (P = .033) after 3 and OR=2.2 (P = .051) after 4 feedback reports. In the course of 1 year, we observed a small and late effect of e-learning and repeated feedback on the quality of spirometry as performed by family practice nurses. This intervention does not seem to compensate the lack of rigorous training and experience in performing spirometry tests in most practices.
Simar, Shelby; Sibley, Diane; Ashcraft, Deborah; Pankey, George
2017-10-01
Polymyxin resistance is an increasing problem worldwide. Currently, determining susceptibility to polymyxins is problematic and lengthy. Polymyxins diffuse poorly into agar, potentially giving inaccurate disk diffusion and Etest results. A rapid screening test (2 h) for the detection of polymyxin resistance in Enterobacteriaceae , developed by P. Nordmann and L. Poirel (rapid polymyxin NP test) in 2016, detects glucose metabolization in the presence of polymyxin E (PE) and PB via pH-induced color change. The sensitivity and specificity were 99.3 and 95.4%, respectively, with results obtained in ≤2 h. Our goal was to evaluate this test using PB against larger numbers of Enterobacter A total of 143 nonduplicate Enterobacter isolates (102 E. cloacae complex, 41 E. aerogenes ) were tested, including 136 collected from Ochsner Health System patients from March to May 2016 and 7 previously determined PB-resistant E. cloacae isolates from JMI Laboratories. MICs were determined via broth microdilution. For the rapid polymyxin NP test, a color change from orange to yellow is positive; a weak/no color change is deemed negative after 4 h. Of 143 Enterobacter isolates, 25 were determined to be PB resistant by broth microdilution (MIC > 2 μg/ml), including all 7 JMI isolates. Of these 25, 7 were positive by the rapid polymyxin NP test (included 3/7 JMI isolates). All 118 isolates determined to be PB susceptible by broth microdilution were NP test negative. The sensitivity and specificity for the rapid polymyxin NP test were 25 and 100%, respectively, compared to broth microdilution. Although the rapid polymyxin NP test is a much faster method (2 to 4 h) for polymyxin resistance determination compared to broth microdilution (16 to 20 h), our study indicates that it may be subject to limitations when testing Enterobacter . Copyright © 2017 American Society for Microbiology.
Test-Enhanced E-Learning Strategies in Postgraduate Medical Education: A Randomized Cohort Study.
DelSignore, Lisa A; Wolbrink, Traci A; Zurakowski, David; Burns, Jeffrey P
2016-11-21
The optimal design of pedagogical strategies for e-learning in graduate and postgraduate medical education remains to be determined. Video-based e-learning use is increasing, with initial research suggesting that taking short breaks while watching videos (independent of answering test questions) may improve learning by focusing attention on the content presented. Interspersed test questions may also improve knowledge acquisition and retention. To examine the effect of interspersed test questions and periodic breaks on immediate knowledge acquisition and retention at 6 months by pediatric residents engaged in video-based e-learning. First- and second-year pediatric residents were randomized to 1 of the following 3 groups: viewing the complete video uninterrupted (full video), viewing the video interrupted with unrelated logic puzzles (logic puzzles), or viewing the video interrupted with brief comprehension test questions (short answer questions). Residents answered pre- and post-tests before and after video viewing, followed by a retention test at 6 months. Primary outcome included comparison of the change in test scores between groups. A total of 49 residents completed the initial testing session. All 3 learning groups had comparable mean increases in immediate knowledge gain, but with no significant differences between groups (F 2,46 =0.35, P=.71). Thirty-five residents completed retention testing with comparable degrees of knowledge retention in the full video and short answer test questions groups (P<.001), but no significant change in the logic puzzles group (F 1,32 =2.44, P=.13). Improved knowledge gain was not demonstrated among residents answering interspersed questions or completing logic puzzles during interrupted online video viewing when compared with residents viewing uninterrupted video content. However, residents who either participated in uninterrupted video viewing or answered interspersed questions during interrupted video viewing demonstrated significant knowledge retention at 6 months. ©Lisa A DelSignore, Traci A Wolbrink, David Zurakowski, Jeffrey P Burns. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 21.11.2016.
Effect of Ovarian Hormone Therapy on Cognition in the Aged Female Rhesus Macaque.
Kohama, Steven G; Renner, Lauren; Landauer, Noelle; Weiss, Alison R; Urbanski, Henryk F; Park, Byung; Voytko, Mary Lou; Neuringer, Martha
2016-10-05
Studies of the effect of hormone therapy on cognitive function in menopausal women have been equivocal, in part due to differences in the type and timing of hormone treatment. Here we cognitively tested aged female rhesus macaques on (1) the delayed response task of spatial working memory, (2) a visuospatial attention task that measured spatially and temporally cued reaction times, and (3) a simple reaction time task as a control for motor speed. After task acquisition, animals were ovariectomized (OVX). Their performance was compared with intact controls for 2 months, at which time no group differences were found. The OVX animals were then assigned to treatment with either a subcutaneous sham implant (OVX), 17-β estradiol (E) implant (OVX+E) or E implant plus cyclic oral progesterone (OVX+EP). All groups were then tested repeatedly over 12 months. The OVX+E animals performed significantly better on the delayed response task than all of the other groups for much of the 12 month testing period. The OVX+EP animals also showed improved performance in the delayed response task, but only at 30 s delays and with performance levels below that of OVX+E animals. The OVX+E animals also performed significantly better in the visuospatial attention task, particularly in the most challenging invalid cue condition; this difference also was maintained across the 12 month testing period. Simple reaction time was not affected by hormonal manipulation. These data demonstrate that chronic, continuous administration of E can exert multiple beneficial cognitive effects in aged, OVX rhesus macaque females. Hormone therapy after menopause is controversial. We tested the effects of hormone replacement in aged rhesus macaques, soon after surgically-induced menopause [ovariectomy (OVX)], on tests of memory and attention. Untreated ovarian-intact and OVX animals were compared with OVX animals receiving estradiol (E) alone or E with progesterone (P). E was administered in a continuous fashion via subcutaneous implant, whereas P was administered orally in a cyclic fashion. On both tests, E-treated animals performed better than the other 3 experimental groups across 1 year of treatment. Thus, in this monkey model, chronic E administered soon after the loss of ovarian hormones had long-term benefits for cognitive function. Copyright © 2016 the authors 0270-6474/16/3610416-09$15.00/0.
Yim, Jin Hee; Kim, Kyoung W; Kim, Sang D
2006-11-02
In this study, the effect of hardness on the combined outcome of metal mixtures was investigated using Daphnia magna. The toxic unit (TU) was calculated using modified LC(50) values based on the hardness (i.e., LC(50-soft) and LC(50-hard)). From a bioassay test, the degree of sensitivity to hardness on the toxicity changes was in the order: Cd
A default Bayesian hypothesis test for mediation.
Nuijten, Michèle B; Wetzels, Ruud; Matzke, Dora; Dolan, Conor V; Wagenmakers, Eric-Jan
2015-03-01
In order to quantify the relationship between multiple variables, researchers often carry out a mediation analysis. In such an analysis, a mediator (e.g., knowledge of a healthy diet) transmits the effect from an independent variable (e.g., classroom instruction on a healthy diet) to a dependent variable (e.g., consumption of fruits and vegetables). Almost all mediation analyses in psychology use frequentist estimation and hypothesis-testing techniques. A recent exception is Yuan and MacKinnon (Psychological Methods, 14, 301-322, 2009), who outlined a Bayesian parameter estimation procedure for mediation analysis. Here we complete the Bayesian alternative to frequentist mediation analysis by specifying a default Bayesian hypothesis test based on the Jeffreys-Zellner-Siow approach. We further extend this default Bayesian test by allowing a comparison to directional or one-sided alternatives, using Markov chain Monte Carlo techniques implemented in JAGS. All Bayesian tests are implemented in the R package BayesMed (Nuijten, Wetzels, Matzke, Dolan, & Wagenmakers, 2014).
Preliminary Report on Oak Ridge National Laboratory Testing of Drake/ACSS/MA2/E3X
DOE Office of Scientific and Technical Information (OSTI.GOV)
Irminger, Philip; King, Daniel J.; Herron, Andrew N.
2016-01-01
A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of a new conductor technology under real world conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr with E3X Technology a standard overhead conductor with an inorganic high emissivity, low absorptivity surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across amore » wide range of operating temperatures, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides initial results of that testing.« less
Jacobson, Mark W; Delis, Dean C; Bondi, Mark W; Salmon, David P
2005-02-01
Some studies of elderly individuals with the ApoE-e4 genotype noted subtle deficits on tests of attention such as the WAIS-R Digit Span subtest, but these findings have not been consistently reported. One possible explanation for the inconsistent results could be the presence of subgroups of e4+ individuals with asymmetric cognitive profiles (i.e., significant discrepancies between verbal and visuospatial skills). Comparing genotype groups with individual, modality-specific tests might obscure subtle differences between verbal and visuospatial attention in these asymmetric subgroups. In this study, we administered the WAIS-R Digit Span and WMS-R Visual Memory Span subtests to 21 nondemented elderly e4+ individuals and 21 elderly e4- individuals matched on age, education, and overall cognitive ability. We hypothesized that a) the e4+ group would show a higher incidence of asymmetric cognitive profiles when comparing Digit Span/Visual Memory Span performance relative to the e4- group; and (b) an analysis of individual test performance would fail to reveal differences between the two subject groups. Although the groups' performances were comparable on the individual attention span tests, the e4+ group showed a significantly larger discrepancy between digit span and spatial span scores compared to the e4- group. These findings suggest that contrast measures of modality-specific attentional skills may be more sensitive to subtle group differences in at-risk groups, even when the groups do not differ on individual comparisons of standardized test means. The increased discrepancy between verbal and visuospatial attention may reflect the presence of "subgroups" within the ApoE-e4 group that are qualitatively similar to asymmetric subgroups commonly associated with the earliest stages of AD.
1. Photographic copy of original engineering drawing for Test Stand ...
1. Photographic copy of original engineering drawing for Test Stand 'C.' California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'New Test Stand Plan -- Edwards Test Station' drawing no. E18/2-3, 18 January 1957. - Jet Propulsion Laboratory Edwards Facility, Test Stand C, Edwards Air Force Base, Boron, Kern County, CA
Bees Algorithm for Construction of Multiple Test Forms in E-Testing
ERIC Educational Resources Information Center
Songmuang, Pokpong; Ueno, Maomi
2011-01-01
The purpose of this research is to automatically construct multiple equivalent test forms that have equivalent qualities indicated by test information functions based on item response theory. There has been a trade-off in previous studies between the computational costs and the equivalent qualities of test forms. To alleviate this problem, we…
The Benefits of Testing for Learning on Later Performance
ERIC Educational Resources Information Center
McConnell, Meghan M.; St-Onge, Christina; Young, Meredith E.
2015-01-01
Testing has been shown to enhance retention of learned information beyond simple studying, a phenomena known as test-enhanced learning (TEL). Research has shown that TEL effects are greater for tests that require the production of responses [e.g., short-answer questions (SAQs)] relative to tests that require the recognition of correct answers…
49 CFR 178.605 - Hydrostatic pressure test.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Hydrostatic pressure test. 178.605 Section 178.605... Packagings and Packages § 178.605 Hydrostatic pressure test. (a) General. The hydrostatic pressure test must... intended to contain liquids and be performed periodically as specified in § 178.601(e). This test is not...
49 CFR 178.605 - Hydrostatic pressure test.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Hydrostatic pressure test. 178.605 Section 178.605... Packagings and Packages § 178.605 Hydrostatic pressure test. (a) General. The hydrostatic pressure test must... intended to contain liquids and be performed periodically as specified in § 178.601(e). This test is not...
Test Anxiety and College Students with Attention Deficit Hyperactivity Disorder
ERIC Educational Resources Information Center
Nelson, Jason M.; Lindstrom, Will; Foels, Patricia A.
2014-01-01
Test anxiety was examined in college students with and without attention deficit hyperactivity disorder (ADHD). Results indicated that, relative to college students without ADHD, college students with ADHD reported higher total test anxiety as well as specific aspects of test anxiety, including worry (i.e., cognitive aspects of test anxiety) and…
Code of Federal Regulations, 2011 CFR
2011-07-01
...). (5) Read and record all required general and pre-test data (i.e., all required data other than data... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Test run. 92.126 Section 92.126... POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.126 Test run. (a) The following steps...
Code of Federal Regulations, 2012 CFR
2012-07-01
...). (5) Read and record all required general and pre-test data (i.e., all required data other than data... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Test run. 92.126 Section 92.126... POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.126 Test run. (a) The following steps...
49 CFR 199.209 - Other requirements imposed by operators.
Code of Federal Regulations, 2011 CFR
2011-10-01
... conducts pre-employment alcohol testing must— (1) Conduct a pre-employment alcohol test before the first... same for the purpose of pre-employment alcohol testing (i.e., you must not test some covered employees and not others); (3) Conduct the pre-employment tests after making a contingent offer of employment or...
Code of Federal Regulations, 2014 CFR
2014-07-01
...). (5) Read and record all required general and pre-test data (i.e., all required data other than data... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Test run. 92.126 Section 92.126... POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.126 Test run. (a) The following steps...
49 CFR 199.209 - Other requirements imposed by operators.
Code of Federal Regulations, 2013 CFR
2013-10-01
... conducts pre-employment alcohol testing must— (1) Conduct a pre-employment alcohol test before the first... same for the purpose of pre-employment alcohol testing (i.e., you must not test some covered employees and not others); (3) Conduct the pre-employment tests after making a contingent offer of employment or...
49 CFR 199.209 - Other requirements imposed by operators.
Code of Federal Regulations, 2012 CFR
2012-10-01
... conducts pre-employment alcohol testing must— (1) Conduct a pre-employment alcohol test before the first... same for the purpose of pre-employment alcohol testing (i.e., you must not test some covered employees and not others); (3) Conduct the pre-employment tests after making a contingent offer of employment or...
Code of Federal Regulations, 2013 CFR
2013-07-01
...). (5) Read and record all required general and pre-test data (i.e., all required data other than data... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Test run. 92.126 Section 92.126... POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.126 Test run. (a) The following steps...
49 CFR 199.209 - Other requirements imposed by operators.
Code of Federal Regulations, 2010 CFR
2010-10-01
... conducts pre-employment alcohol testing must— (1) Conduct a pre-employment alcohol test before the first... same for the purpose of pre-employment alcohol testing (i.e., you must not test some covered employees and not others); (3) Conduct the pre-employment tests after making a contingent offer of employment or...
49 CFR 199.209 - Other requirements imposed by operators.
Code of Federal Regulations, 2014 CFR
2014-10-01
... conducts pre-employment alcohol testing must— (1) Conduct a pre-employment alcohol test before the first... same for the purpose of pre-employment alcohol testing (i.e., you must not test some covered employees and not others); (3) Conduct the pre-employment tests after making a contingent offer of employment or...
Code of Federal Regulations, 2010 CFR
2010-07-01
...). (5) Read and record all required general and pre-test data (i.e., all required data other than data... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Test run. 92.126 Section 92.126... POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.126 Test run. (a) The following steps...
49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?
Code of Federal Regulations, 2011 CFR
2011-10-01
... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...
49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?
Code of Federal Regulations, 2012 CFR
2012-10-01
... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...
49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?
Code of Federal Regulations, 2010 CFR
2010-10-01
... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...
49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?
Code of Federal Regulations, 2014 CFR
2014-10-01
... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...
49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?
Code of Federal Regulations, 2013 CFR
2013-10-01
... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...
A Guided Summary Completion Test for Long Academic Texts.
ERIC Educational Resources Information Center
Bensoussan, Marsha
Because testing comprehension of long (5- to 10-page) second-language texts is more complex than testing shorter texts, an alternative form of second language reading comprehension test is needed. In a guided summary completion test, students are presented with a greatly shortened version of the text (e.g., one-paragraph summary), containing…