Automated data collection equipment for monitoring highway condition.
DOT National Transportation Integrated Search
2005-06-01
This study was conducted to evaluate automated vehicle mounted equipment to collect data on the needs of : Oregons highway inventory. Four vendors accepted invitations to evaluate their equipment. Although ODOT had : conducted a similar evaluation...
Evaluation of artillery equipment maintenance support capability based on grey clustering
NASA Astrophysics Data System (ADS)
Zhai, Mei-jie; Gao, Peng
2017-12-01
This paper, the theory and method of evaluating the capability of equipment maintenance support in China and abroad are studied, from the point of view of the combat task of artillery troops and the strategic attachment in the future military struggle. This paper establishes the framework of the evaluation Index system of the equipment maintenance support capability of the artillery units, and applies the grey clustering method to the evaluation of the equipment maintenance support capability of the artillery units, and finally evaluates the equipment maintenance and support capability of the artillery brigade as an example, and analyzes the evaluation results. This paper finds out the outstanding problems existing in the maintenance and support of military equipment, and puts forward some constructive suggestions, in order to improve the status of military equipment maintenance and support and improve the level of future equipment maintenance.
A study on the real-time reliability of on-board equipment of train control system
NASA Astrophysics Data System (ADS)
Zhang, Yong; Li, Shiwei
2018-05-01
Real-time reliability evaluation is conducive to establishing a condition based maintenance system for the purpose of guaranteeing continuous train operation. According to the inherent characteristics of the on-board equipment, the connotation of reliability evaluation of on-board equipment is defined and the evaluation index of real-time reliability is provided in this paper. From the perspective of methodology and practical application, the real-time reliability of the on-board equipment is discussed in detail, and the method of evaluating the realtime reliability of on-board equipment at component level based on Hidden Markov Model (HMM) is proposed. In this method the performance degradation data is used directly to realize the accurate perception of the hidden state transition process of on-board equipment, which can achieve a better description of the real-time reliability of the equipment.
NASA Astrophysics Data System (ADS)
Mohammadi, Mousa; Rai, Piyush; Gupta, Suprakash
2017-03-01
Overall Equipment Effectiveness (OEE) has been used since last over two decades as a measure of performance in manufacturing industries. Unfortunately, enough, application of OEE in mining and excavation industry has not been duly adopted. In this paper an effort has been made to identify the OEE for performance evaluation of Bucket based Excavating, Loading and Transport (BELT) equipment. The conceptual model of OEE, as used in the manufacturing industries, has been revised to adapt to the BELT equipment. The revised and adapted model considered the operational time, speed and bucket capacity utilization losses as the key OEE components for evaluating the performance of BELT equipment. To illustrate the efficacy of the devised model on real-time basis, a case study was undertaken on the biggest single bucket excavating equipment - the dragline, in a large surface coal mine. One-year data was collected in order to evaluate the proposed OEE model.
Study on the Selection of Equipment Suppliers for Wind Power Generation EPC Project
NASA Astrophysics Data System (ADS)
Yang, Yuanyue; Li, Huimin
2017-12-01
In the EPC project, the purchase cost of equipments accounted for about 60% of the total project cost, thus, the selection of equipment suppliers has an important influence on the EPC project. This paper, took EPC project for the phase I engineering of Guizhou Huaxi Yunding wind power plant as research background, constructed the evaluation index system for the selection of equipment suppliers for wind power generation EPC project from multiple perspectives, and introduced matter-element extension evaluation model to evaluate the selection of equipment suppliers for this project from the qualitative and quantitative point of view. The result is consistent with the actual situation, which verifies the validity and operability of this method.
PILOT-SCALE EVALUATION OF NEW RESIN APPLICATION EQUIPMENT FOR FIBER- REINFORCED PLASTICS
The article gives results of a pilot-scale evaluation of new resin application equipment for fiber- reinforced plastics. The study, an evaluation and comparison of styrene emissions, utilized Magnum's FIT(TM) nozzle with conventional spray guns and flow coaters (operated at both ...
Kittusamy, N Kumar; Buchholz, Bryan
2004-01-01
Operators of construction equipment perform various duties at work that expose them to a variety of risk factors that may lead to health problems. A few of the health hazards among operators of construction equipment are: (a) whole-body vibration, (b) awkward postural requirements (including static sitting), (c) dust, (d) noise, (e) temperature extremes, and (f) shift work. It has been suggested that operating engineers (OEs) are exposed to two important risk factors for the development of musculoskeletal disorders: whole-body vibration and non-neutral body postures. This review evaluates selected papers that have studied exposure to whole-body vibration and awkward posture among operators of mobile equipment. There have been only few studies that have specifically examined exposure of these risk factors among operators of construction equipment. Thus other studies from related industry and equipment were reviewed as applicable. In order to better understand whole-body vibration and postural stress among OEs, it is recommended that future studies are needed in evaluating these risk factors among OEs.
STS ancillary equipment study. User reference book
NASA Technical Reports Server (NTRS)
Plough, J. A.
1977-01-01
A record of what is currently known about STS ancillary equipment is presented in this user-oriented design so that a potential user may evaluate whether he could use the described ancillary equipment or if he would need to design and fabricate a payload-unique item. References that the user can use to obtain additional details and requirements to aid in his evaluation and decision are included.
An Evaluation Method of Equipment Reliability Configuration Management
NASA Astrophysics Data System (ADS)
Wang, Wei; Feng, Weijia; Zhang, Wei; Li, Yuan
2018-01-01
At present, many equipment development companies have been aware of the great significance of reliability of the equipment development. But, due to the lack of effective management evaluation method, it is very difficult for the equipment development company to manage its own reliability work. Evaluation method of equipment reliability configuration management is to determine the reliability management capabilities of equipment development company. Reliability is not only designed, but also managed to achieve. This paper evaluates the reliability management capabilities by reliability configuration capability maturity model(RCM-CMM) evaluation method.
Uskun, Ersin; Kişioğlu, Ahmet Nesimi; Altay, Tülin; Cikinlar, Rengül; Kocakaya, Asuman
2008-01-01
This study aimed to identify and evaluate the degree of conformity to the playground standards and the level of compliance with current safety specifications of the playgrounds in the midwestern region of Turkey. An observational technique was used at a total of 57 public playgrounds. A playground safety control form was prepared based on the United States National Program for Playground Safety and the Consumer Product Safety Commission security standards, since there is no national law covering playground equipment and safety in Turkey. The study evaluated the surroundings of the playground, arrangement of equipment in the playground, and characteristics of the equipment. The percentage of playgrounds surveyed with inadequate or hard surfacing was 80.7%. Fifty-two percent of the equipment was found to be inappropriate. Equipment was higher than the recommended heights. The results of our study unfortunately point out that playgrounds for children do not meet many of the safety criteria.
A Perceptual Measure of the Degree of Development of Proprietary Equipment.
ERIC Educational Resources Information Center
Cua, Kristy O.; Junttila, Mikko A.; Schroeder, Roger G.
2002-01-01
Evaluated the psychometric properties of a perceptual measure of the extent to which manufacturing organizations develop proprietary equipment, the Proprietary Equipment Scale (developed by the World Class Manufacturing study). Analysis of data from 164 manufacturing plants in 5 countries indicates that although method effects are present, the…
Research on the use of data fusion technology to evaluate the state of electromechanical equipment
NASA Astrophysics Data System (ADS)
Lin, Lin
2018-04-01
Aiming at the problems of different testing information modes and the coexistence of quantitative and qualitative information in the state evaluation of electromechanical equipment, the paper proposes the use of data fusion technology to evaluate the state of electromechanical equipment. This paper introduces the state evaluation process of mechanical and electrical equipment in detail, uses the D-S evidence theory to fuse the decision-making layers of mechanical and electrical equipment state evaluation and carries out simulation tests. The simulation results show that it is feasible and effective to apply the data fusion technology to the state evaluation of the mechatronic equipment. After the multiple decision-making information provided by different evaluation methods are fused repeatedly and the useful information is extracted repeatedly, the fuzziness of judgment can be reduced and the state evaluation Credibility.
NASA Technical Reports Server (NTRS)
Daniledes, J.; Koch, J. R.
1980-01-01
The risk associated with the accidental release of carbon/graphite fibers (CF) from fires on commercial transport aircraft incorporating composite materials was assessed. Data are developed to evaluate the potential for CF damage to electrical and electronic equipment, assess the cost risk, and evaluate the hazard to continued operation. The subjects covered include identification of susceptible equipments, determination of infiltration transfer functions, analysis of airport operations, calculation of probabilities of equipment failures, assessment of the cost risk, and evaluation of the hazard to continued operation. The results show the risks associated with CF contamination are negligible through 1993.
Hou, Fujun
2016-01-01
This paper provides a description of how market competitiveness evaluations concerning mechanical equipment can be made in the context of multi-criteria decision environments. It is assumed that, when we are evaluating the market competitiveness, there are limited number of candidates with some required qualifications, and the alternatives will be pairwise compared on a ratio scale. The qualifications are depicted as criteria in hierarchical structure. A hierarchical decision model called PCbHDM was used in this study based on an analysis of its desirable traits. Illustration and comparison shows that the PCbHDM provides a convenient and effective tool for evaluating the market competitiveness of mechanical equipment. The researchers and practitioners might use findings of this paper in application of PCbHDM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-01
The study has been undertaken by the Glosten Associates, Inc., to evaluate the existing capability for emergency towing at Prince William Sound and to examine alternatives that could enhance the escort and assist capabilities for disabled tankers within the waterway from the Alyeska Oil Terminal at the Port of Valdez to the Gulf of Alaska outside Hinchinbrook Entrance. Part 1, reported herein, is an objective evaluation by an experienced salvage towing master of the existing tugs, emergency towing equipment, towing practices, and discussion of alternative tug types.
NASA Astrophysics Data System (ADS)
Buică, G.; Beiu, C.; Antonov, A.; Dobra, R.; Păsculescu, D.
2017-06-01
The protecting electrical equipment in use are subject to various factors generated by the use, maintenance, storage and working environment, which may change the characteristics of protection against electric shock. The study presents the results of research on the behaviour over time of protective characteristics of insulating covers of material of work equipment in use, in order to determine the type and periodicity of safety tests. There were tested and evaluated safety equipment with plastic and insulating rubber covers used in operations of verifying functionality, safety and maintenance of machinery used in manufacturing industries and specific services from electric, energy and food sector.
NASA Astrophysics Data System (ADS)
Drygin, Michael; Kuryshkin, Nicholas
2017-11-01
The article tells about forming a new concept of scheduled preventive repair system of the equipment at coal mining enterprises, based on the use of modem non-destructive evaluation methods. The approach to the solution for this task is based on the system-oriented analysis of the regulatory documentation, non-destructive evaluation methods and means, experimental studies with compilation of statistics and subsequent grapho-analytical analysis. The main result of the work is a feasible explanation of using non-destructive evaluation methods within the current scheduled preventive repair system, their high efficiency and the potential of gradual transition to condition-based maintenance. In practice wide use of nondestructive evaluation means w;ill allow to reduce significantly the number of equipment failures and to repair only the nodes in pre-accident condition. Considering the import phase-out policy, the solution for this task will allow to adapt the SPR system to Russian market economy conditions and give the opportunity of commercial move by reducing the expenses for maintenance of Russian-made and imported equipment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Usui, Hideo; Izumo, Sari; Tachibana, Mitsuo
Some of nuclear facilities that would no longer be required have been decommissioned in JAEA (Japan Atomic Energy Agency). A lot of nuclear facilities have to be decommissioned in JAEA in near future. To implement decommissioning of nuclear facilities, it was important to make a rational decommissioning plan. Therefore, project management data evaluation system for dismantling activities (PRODIA code) has been developed, and will be useful for making a detailed decommissioning plan for an object facility. Dismantling of dry conversion facility in the uranium refining and conversion plant (URCP) at Ningyo-toge began in 2008. During dismantling activities, project management datamore » such as manpower and amount of waste generation have been collected. Such collected project management data has been evaluated and used to establish a calculation formula to calculate manpower for dismantling equipment of chemical process and calculate manpower for using a green house (GH) which was a temporary structure for preventing the spread of contaminants during dismantling. In the calculation formula to calculate project management data related to dismantling of equipment, the relation of dismantling manpower to each piece of equipment was evaluated. Furthermore, the relation of dismantling manpower to each chemical process was evaluated. The results showed promise for evaluating dismantling manpower with respect to each chemical process. In the calculation formula to calculate project management data related to use of the GH, relations of GH installation manpower and removal manpower to GH footprint were evaluated. Furthermore, the calculation formula for secondary waste generation was established. In this study, project management data related to dismantling of equipment and use of the GH were evaluated and analyzed. The project management data, manpower for dismantling of equipment, manpower for installation and removal of GH, and secondary waste generation from GH were considered. Establishment of the calculation formula for dismantling of each kind of equipment makes it possible to evaluate manpower for dismantling the whole facility. However, it is not easy to prepare calculation formula for all kinds of equipment that exist in the facility. Therefore, a simpler evaluation method was considered to calculate manpower based on facility characteristics. The results showed promise for evaluating dismantling manpower with respect to each chemical process. For dismantling of contaminated equipment, a GH has been used for protection of the spread of contamination. The use of a GH increases manpower for installation and removal of GH etc. Moreover, structural materials of the GH such as plastic sheets, adhesive tape become a burnable secondary waste. To create an effective dismantling plan, it is necessary to carefully consider use of a GH preliminarily. Thus, an evaluation method of project management data such as manpower and secondary waste generation was considered. The results showed promise for evaluating project management data of GH by using established calculation formula. (authors)« less
Relationship Between Site Disturbance and Forest Harvesting Equipment Traffic
Tim McDonald; Emily Carter; Steve Taylor; John Tobert
1998-01-01
A study was done to evaluate the use of global positioning systems (GPS) to track the position of forest harvesting equipment and use the information to assess site impacts. GPS units were attached to tree-length harvesting machinery in two clearcuts (1 feller-buncher, 2 skidders). Position of the equipment was recorded at 2-second intervals throughout the harvest of...
Evaluation of passive and active vibration control mechanisms in a microgravity environment
NASA Technical Reports Server (NTRS)
Ellison, J.; Ahmadi, G.; Grodsinsky, C.
1993-01-01
The behavior of equipment and their light secondary attachments in large space structures under orbital excitation is studied. The equipment is modeled as a shear beam and its secondary attachment is treated as a single-degree-of-freedom lumped mass system. Peak responses of the equipment and its secondary system for a variety of vibration control mechanisms are evaluated. A novel active friction control mechanism, by varying the normal force, is suggested. The device uses a magnetic field control to minimize the stick condition, thereby reducing the overall structural response. The results show that the use of the passive vibration control devices could reduce the peak equipment responses to a certain extent. However, major reduction of vibration levels could be achieved only by the use of active devices. Using active control of the interface normal force, the peak responses of the equipment and its attachment are reduced by a factor of 10 over the fixed-base equipment response.
NASA Astrophysics Data System (ADS)
Ito, Katsuji; Hirose, Yasuo
Overvoltage induced by surge currents due to thunderstorm lightnings causes harmful breakdown troubles of CATV communication equipment installed in and with power distribution systems. In this paper, the origin and natures of surge currents, their invading route into the system, and the system components such as earth impedances affecting over voltages are studied. Transient analyses are then performed using an equivalent circuit to evaluate over voltages. Application of the obtained results to the field fault data of communication equipment and possible protection method of them are discussed.
Research on invulnerability of equipment support information network
NASA Astrophysics Data System (ADS)
Sun, Xiao; Liu, Bin; Zhong, Qigen; Cao, Zhiyi
2013-03-01
In this paper, the entity composition of equipment support information network is studied, and the network abstract model is built. The influence factors of the invulnerability of equipment support information network are analyzed, and the invulnerability capabilities under random attack are analyzed. According to the centrality theory, the materiality evaluation centralities of the nodes are given, and the invulnerability capabilities under selective attack are analyzed. Finally, the reasons that restrict the invulnerability of equipment support information network are summarized, and the modified principles and methods are given.
Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security
West, David L.; Wood, Nathan L.; Forrester, Christina D.
2017-12-01
This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion ofmore » typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.« less
Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security
DOE Office of Scientific and Technical Information (OSTI.GOV)
West, David L.; Wood, Nathan L.; Forrester, Christina D.
This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion ofmore » typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.« less
Laser range pole field evaluation report
NASA Technical Reports Server (NTRS)
1973-01-01
A field evaluation was made of the laser pole equipment. The basic plan for the evaluation was to expose the equipment to the actual people and environment for which it was intended and determine, through the use of the equipment, its resultant effectivity in terms of improved performance. Results show the equipment performed better than expected in the high elevation clean air of Colorado, and did as well in Tennessee.
Amaral, Pedro Vasconcelos; Rocha, Thiago Augusto Hernandes; Barbosa, Allan Claudius Queiroz; Lein, Adriana; Vissoci, João Ricardo Nickenig
2017-12-04
Access to health services is in part defined by the spatial distribution of healthcare equipment. To ensure equity in the provision of health services, it is important to examine availability across different health care providers taking into account population demand. Given the importance of the equitable provision of health equipment, we evaluate its spatial distribution in Brazil. This study is classified as cross-sectional with an ecological design. We evaluate Brazilian data on distance to available health equipment considering: dialysis machines (385), magnetic resonance imaging (MRI) (257), hospital beds (3675) and bone densitometers (429). We define two distance thresholds (50 km and 200 km) from a municipality to the center of services provision. The balance between infrastructure capacity and potential demand was evaluated to identify a lack or surplus of health services. The distribution of dialysis equipment and bone densitometers is not balanced across Brazilian states, and unmet demand is high. With respect to MRIs, the large capacity of this equipment results in a large excess of supply. However, this characteristic alone cannot account for excesses of supply of over 700%, as is the case of the Federal District when the range is limited to 50 km. At the same time, four states in the Northeastern region of Brazil show a net excess of demand. Some regions do not meet the standard amount of supply defined by Brazilian Ministry of Health. The quantity and distribution of hospital beds are not sufficient to provide full coverage to the population. Our main focus was to evaluate the network of the provision of health equipment in Brazil, considering both private and public sectors conjointly. We take into account two main aspects of a spatially balanced health system: the regional availability of health equipment and the geographic distance between its demand and supply at the municipality level. Some regions do not meet the minimum requirement defined by the Brazilian Ministry of Health regarding the supply of health services.
Ground penetrating radar study--phase I : technology review and evaluation.
DOT National Transportation Integrated Search
2006-08-01
In December 2005 Mississippi Department of Transportation (MDOT) initiated State Study No. 182 on review : and evaluation of ground penetrating radar (GPR) technology. This Phase I study has reviewed GPR equipment : and data interpretation methodolog...
DOT National Transportation Integrated Search
2013-03-01
This study has identified, evaluated and synthesized the best practices that can be implemented to minimize the corrosive effects of chloride deicers on DOT winter application equipment and vehicles. The practices identified include: design improveme...
AIR CONTAMINANT EXPOSURE DURING THE OPERATION OF LAWN AND GARDEN EQUIPMENT
The U.S. Environmental Protection Agency (EPA) initiated the Small Engine Exposure Study (SEES) to evaluate potential exposures among users of small, gasoline-powered, non-road spark-ignition (SI) lawn and garden engines. Equipment tested included riding tractors, walk-behind la...
Californium-252 Program Equipment Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chattin, Fred Rhea; Wilson, Kenton; Ezold, Julie G.
2017-12-01
To successfully continue the 252Cf production and meet the needs of the customers, a comprehensive evaluation of the Building 7920 processing equipment was requested to identify equipment critical to the operational continuity of the program.
[Fabrication of annealing equipment for optically stimulated luminescence (OSL) dosimeter].
Nakagawa, Kohei; Hayashi, Hiroaki; Okino, Hiroki; Takegami, Kazuki; Okazaki, Tohru; Kobayashi, Ikuo
2014-10-01
The optically stimulated luminescence (OSL) dosimeter is a useful detector for measuring absorbed doses of X-rays. A small-type OSL dosimeter, "nanoDot", has recently been developed by Landauer, Inc., who also manufacture "microStar" reading equipment. However, additional annealing equipment is needed if the nanoDot OSL dosimeter is used repeatedly. The aim of this study was to fabricate suitable annealing equipment using commonly available products. Our device positions four fluorescent light tubes in a close configuration. The heat from the fluorescent light tubes is dissipated using fans. Experiments using diagnostic X-ray equipment were carried out to evaluate the capability of our annealing equipment. The results indicated that our equipment can fully anneal the nanoDot OSL dosimeter with annealing times of approximately 20 hours.
Kidholm, Kristian; Kristensen, Mie Borch Dahl
2018-04-01
Many countries have considered telemedicine and home monitoring of patients as a solution to the demographic challenges that health-care systems face. However, reviews of economic evaluations of telemedicine have identified methodological problems in many studies as they do not comply with guidelines. The aim of this study was to examine economic evaluations alongside randomised controlled trials of home monitoring in chronic disease management and hereby to explore the resources included in the programme costs, the types of health-care utilisation that change as a result of home monitoring and discuss the value of economic evaluation alongside randomised controlled trials of home monitoring on the basis of the studies identified. A scoping review of economic evaluations of home monitoring of patients with chronic disease based on randomised controlled trials and including information on the programme costs and the costs of equipment was carried out based on a Medline (PubMed) search. Nine studies met the inclusion criteria. All studies include both costs of equipment and use of staff, but there is large variation in the types of equipment and types of tasks for the staff included in the costs. Equipment costs constituted 16-73% of the total programme costs. In six of the nine studies, home monitoring resulted in a reduction in primary care or emergency contacts. However, in total, home monitoring resulted in increased average costs per patient in six studies and reduced costs in three of the nine studies. The review is limited by the small number of studies found and the restriction to randomised controlled trials, which can be problematic in this area due to lack of blinding of patients and healthcare professionals and the difficulty of implementing organisational changes in hospital departments for the limited period of a trial. Furthermore, our results may be based on assessments of older telemedicine interventions.
Shuttle orbiter S-band communications equipment design evaluation
NASA Technical Reports Server (NTRS)
Springett, J. C.
1979-01-01
An assessment of S-band communication equipment includes: (1) the review and analysis of the ability of the various subsystem avionic equipment designs to interface with, and operate on signals from/to adjoining equipment; (2) the performance peculiarities of the hardware against the overall specified system requirements; and (3) the evaluation of EMC EMI test results of the various equipment with respect to the possibility of mutual interferences.
Evaluation of alternative snowplowable markers and snowplowing procedures.
DOT National Transportation Integrated Search
2013-06-01
The objectives of this study were to investigate viable alternatives to the currently approved snowplowable raised pavement marker and alternative methods and equipment used to snowplow roadways. The study included evaluating any potential durable an...
NASA Astrophysics Data System (ADS)
Kasashima, Yuji; Tsutsumi, Kota; Mitomi, Shinzo; Uesugi, Fumihiko
2017-06-01
In mass-production plasma etching equipment, the corrosion of ceramic chamber parts reduces the production yield of LSI and overall equipment effectiveness (OEE) owing to contamination, short useful life, and particle generation. Novel ceramics that can improve the production yield and OEE are highly required. We develop magnesium oxide (MgO)-based ceramics and evaluate them under mass-production plasma etching conditions. The results of this study indicate that the developed MgO-based ceramics with high mechanical properties and low electric resistivity have a higher resistance to corrosion in plasma etching using CF4 gas than Si and conventional ceramic materials such as aluminum oxide and yttrium oxide.
Applicability of Monte-Carlo Simulation to Equipment Design of Radioactive Noble Gas Monitor
NASA Astrophysics Data System (ADS)
Sakai, Hirotaka; Hattori, Kanako; Umemura, Norihiro
In the nuclear facilities, radioactive noble gas is continuously monitored by using the radioactive noble gas monitor with beta-sensitive plastic scintillation radiation detector. The detection efficiency of the monitor is generally calibrated by using a calibration loop and standard radioactive noble gases such as 85Kr. In this study, the applicability of PHITS to the equipment design of the radioactive noble gas monitor was evaluated by comparing the calculated results to the test results obtained by actual calibration loop tests to simplify the radiation monitor design evaluation. It was confirmed that the calculated results were well matched to the test results of the monitor after the modeling. In addition, the key parameters for equipment design, such as thickness of detector window or depth of the sampler, were also specified and evaluated.
Evaluation of the effectiveness of peracetic acid in the sterilization of dental equipment.
Ceretta, R; Paula, M M S; Angioletto, Ev; Méier, M M; Mitellstädt, F G; Pich, C T; Junior, S A; Angioletto, E
2008-01-01
To evaluate the effectiveness of peracetic acid in the microbiological sterilisation of dental materials. Peracetic acid solution was evaluated at concentrations of 800, 1500 and 2500 ppm. At these concentrations, it was determined whether peracetic acid caused corrosion to dental instruments and induced cellular mutagenicity and cytotoxicity. In addition, the minimum inhibitory concentration (MIC), the minimum bactericidal concentration (MBC), agar diffusion and diffusion by well method, were also verified. The corrosion rate, calculated from potentiodynamic assays was 10(-6) cm/year, indicating that the product does not damage equipment. The sterilisation capacity of peracetic acid at 2500 ppm was the best. The comet assay indicated genotoxic activity at 2500 ppm. This study demonstrated the effectiveness of peracetic acid for sterilizing dental equipment, providing another alternative for the prevention of infections in clinics.
DOT National Transportation Integrated Search
2015-01-01
One of the objectives of this study was to evaluate soil testing equipment based on its capability of measuring in-place stiffness or modulus values. : As design criteria transition from empirical to mechanistic-empirical, soil test methods and equip...
da Rocha, Leticia; Sloane, Elliot; M Bassani, Jose
2005-01-01
This study describes a framework to support the choice of the maintenance service (in-house or third party contract) for each category of medical equipment based on: a) the real medical equipment maintenance management system currently used by the biomedical engineering group of the public health system of the Universidade Estadual de Campinas located in Brazil to control the medical equipment maintenance service, b) the Activity Based Costing (ABC) method, and c) the Analytic Hierarchy Process (AHP) method. Results show the cost and performance related to each type of maintenance service. Decision-makers can use these results to evaluate possible strategies for the categories of equipment.
Akşam, Berrak; Akşam, Ersin; Ceran, Candemir; Demirseren, Mustafa Erol
2016-01-01
The purpose of this study was to describe the role of public exercise equipment in pediatric hand traumas as a preventable etiological factor. Pediatric patients with hand injuries referred from the emergency department were evaluated retrospectively. Age and gender of the patients, timing, etiology, mechanism of hand trauma, localization of the injury, diagnoses of the patients, and hospitalization rates were reviewed. Amongst the 310 pediatric patients evaluated, 31 patients (10%) experienced injury related to public exercise equipment. Within this group of patients, most were between 5 to 9 years of age, and all injuries were blunt and crush type. Lacerations and fractures were the main diagnoses. Complex injuries that required inpatient care were reported in 19.3% of the patients. Public exercise equipment-related injuries are increasingly prevalent in pediatric hand traumas. Preventive actions such as shielding the moving parts should be taken to reduce these rates.
Treatment options for tank farms long-length contaminated equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Josephson, W.S.
1995-10-16
This study evaluated a variety of treatment and disposal technologies for mixed waste (MW) meeting the following criteria: 1. Single-Shell and Double-Shell Tank System (tank farms) equipment and other debris; 2. length greater than 12 feet; and contaminated with listed MW from the tank farms. This waste stream, commonly referred to as tank farms long-length contaminated equipment (LLCE), poses a unique and costly set of challenges during all phases of the waste management lifecycle.
TOPEX satellite concept. TOPEX option study report
NASA Technical Reports Server (NTRS)
Meyer, D. P.; Case, C. M.
1982-01-01
Candidate bus equipment from the Viking, Applications Explorer Mission, and Small Scientific Satellite programs for application to the TOPEX mission options is assessed. Propulsion module equipment and subsystem candidates from the Applications Explorer Mission satellites and the Small Scientific Satellite spacecraft are evaluated for those TOPEX options. Several subsystem concepts appropriate to the TOPEX options are described. These descriptions consider performance characteristics of the subsystems. Cost and availability information on the candidate equipment and subsystems are also provided.
2010-05-01
decontaminate chemical and biological agents from sensitive equipment (avionics, electronics, electrical , and environmental systems and equipment...fabricated 2 x 2 in. square, 3/32 in. thick aluminum shims, augmented with electrical tape for added thickness as needed, were used in these tests to make...test coupons, thin custom-fabricated 2x2 in. square x 3/32 in. thick aluminum shims, augmented with electrical tape for added thickness as needed
Vlasov, A A; Vazhenin, A V; Plotnikov, V V; Spirev, V V; Chinarev, Iu B
2010-01-01
The study is concerned with development of equipment for forming circular compression intestinal anastomosis using the "form memory" effect and super-elasticity of titanium nickelide. A sequence of technological operations is suggested, experimental tests and clinical trials carried out and immediate and end-results for anterior resection in rectal cancer are evaluated. Compression equipment for forming colorectal anastomosis proved reliable in long-term operation.
Lunar-base construction equipment and methods evaluation
NASA Technical Reports Server (NTRS)
Boles, Walter W.; Ashley, David B.; Tucker, Richard L.
1993-01-01
A process for evaluating lunar-base construction equipment and methods concepts is presented. The process is driven by the need for more quantitative, systematic, and logical methods for assessing further research and development requirements in an area where uncertainties are high, dependence upon terrestrial heuristics is questionable, and quantitative methods are seldom applied. Decision theory concepts are used in determining the value of accurate information and the process is structured as a construction-equipment-and-methods selection methodology. Total construction-related, earth-launch mass is the measure of merit chosen for mathematical modeling purposes. The work is based upon the scope of the lunar base as described in the National Aeronautics and Space Administration's Office of Exploration's 'Exploration Studies Technical Report, FY 1989 Status'. Nine sets of conceptually designed construction equipment are selected as alternative concepts. It is concluded that the evaluation process is well suited for assisting in the establishment of research agendas in an approach that is first broad, with a low level of detail, followed by more-detailed investigations into areas that are identified as critical due to high degrees of uncertainty and sensitivity.
Analysis of flow field characteristics in IC equipment chamber based on orthogonal design
NASA Astrophysics Data System (ADS)
Liu, W. F.; Yang, Y. Y.; Wang, C. N.
2017-01-01
This paper aims to study the influence of the configuration of processing chamber as a part of IC equipment on flow field characteristics. Four parameters, including chamber height, chamber diameter, inlet mass flow rate and outlet area, are arranged using orthogonally design method to study their influence on flow distribution in the processing chamber with the commercial software-Fluent. The velocity, pressure and temperature distribution above the holder were analysed respectively. The velocity difference value of the gas flow above the holder is defined as the evaluation criteria to evaluate the uniformity of the gas flow. The quantitative relationship between key parameters and the uniformity of gas flow was found through analysis of experimental results. According to our study, the chamber height is the most significant factor, and then follows the outlet area, chamber diameter and inlet mass flow rate. This research can provide insights into the study and design of configuration of etcher, plasma enhanced chemical vapor deposition (PECVD) equipment, and other systems with similar configuration and processing condition.
In vitro motility evaluation of aggregated cancer cells by means of automatic image processing.
De Hauwer, C; Darro, F; Camby, I; Kiss, R; Van Ham, P; Decaesteker, C
1999-05-01
Set up of an automatic image processing based method that enables the motility of in vitro aggregated cells to be evaluated for a number of hours. Our biological model included the PC-3 human prostate cancer cell line growing as a monolayer on the bottom of Falcon plastic dishes containing conventional culture media. Our equipment consisted of an incubator, an inverted phase contrast microscope, a Charge Coupled Device (CCD) video camera, and a computer equipped with an image processing software developed in our laboratory. This computer-assisted microscope analysis of aggregated cells enables global cluster motility to be evaluated. This analysis also enables the trajectory of each cell to be isolated and parametrized within a given cluster or, indeed, the trajectories of individual cells outside a cluster. The results show that motility inside a PC-3 cluster is not restricted to slight motion due to cluster expansion, but rather consists of a marked cell movement within the cluster. The proposed equipment enables in vitro aggregated cell motility to be studied. This method can, therefore, be used in pharmacological studies in order to select anti-motility related compounds. The compounds selected by the equipment described could then be tested in vivo as potential anti-metastatic.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sari Izumo; Hideo Usui; Mitsuo Tachibana
Evaluation models for determining the manpower needs for dismantling various types of equipment in uranium refining and conversion plant (URCP) have been developed. The models are widely applicable to other uranium handling facilities. Additionally, a simplified model was developed for easily and accurately calculating the manpower needs for dismantling dry conversion process-related equipment (DP equipment). It is important to evaluate beforehand project management data such as manpower needs to prepare an optimized decommissioning plan and implement effective dismantling activity. The Japan Atomic Energy Agency (JAEA) has developed the project management data evaluation system for dismantling activities (PRODIA code), which canmore » generate project management data using evaluation models. For preparing an optimized decommissioning plan, these evaluation models should be established based on the type of nuclear facility and actual dismantling data. In URCP, the dry conversion process of reprocessed uranium and others was operated until 1999, and the equipment related to the main process was dismantled from 2008 to 2011. Actual data such as manpower for dismantling were collected during the dismantling activities, and evaluation models were developed using the collected actual data on the basis of equipment classification considering the characteristics of uranium handling facility. (authors)« less
Braking and cornering studies on an air cushion landing system
NASA Technical Reports Server (NTRS)
Daugherty, R. H.
1983-01-01
An experimental investigation was conducted to evaluate several concepts for braking and steering a vehicle equipped with an air cushion landing system (ACLS). The investigation made use of a modified airboat equipped with an ACLS. Braking concepts were characterized by the average deceleration of the vehicle. Reduced lobe flow and cavity venting braking concepts were evaluated in this program. The cavity venting braking concept demonstrated the best performance, producing decelerations on the test vehicle on the same order as moderate braking with conventional wheel brakes. Steering concepts were evaluated by recording the path taken while attempting to follow a prescribed maneuver. The steering concepts evaluated included using rudders only, using differential lobe flow, and using rudders combined with a lightly loaded, nonsteering center wheel. The latter concept proved to be the most accurate means of steering the vehicle on the ACLS, producing translational deviations two to three times higher than those from conventional nose-gear steering. However, this concept was still felt to provide reasonably precise steering control for the ACLS-equipped vehicle.
Miyake, Masateru; Kondo, Satoshi; Koga, Toshihisa; Yoda, Noriaki; Nakazato, Satoru; Emoto, Chie; Mukai, Tadashi; Toguchi, Hajime
2018-01-01
The purpose of this study was to evaluate the intestinal metabolism and absorption in a mini-Ussing chamber equipped with animal intestinal tissues, based on the transport index (TI). TI value was defined as the sum of drug amounts transported to the basal-side component (X corr ) and drug amounts accumulated in the tissue (T corr ), which are normalized by AUC of a drug in the apical compartment, as an index for drug absorption. Midazolam was used as a test compound for the evaluation of intestinal metabolism and absorption. The metabolite formulation of midazolam was observed in both rats and dogs. Ketoconazole inhibited the intestinal metabolism of midazolam in rats and improved its intestinal absorption to a statistically significant extent. Therefore, the mini-Ussing chamber, equipped with animal intestinal tissues, showed potential to use the evaluation of the intestinal metabolism and absorption, including the assessment of species differences. Copyright © 2017. Published by Elsevier B.V.
Evaluation of a disposable diesel exhaust filter for permissible mining machines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ambs, J.L.; Cantrell, B.K.; Watts, W.F.
1994-01-01
The US Bureau of Mines (USBM) Diesel Research Program emphasizes the development and evaluation of emission control devices to reduce exposure of miners to diesel exhaust pollutants. Studies by the USBM have shown that diesel exhaust aerosol (DEA) contributes a substantial portion of the respirable aerosol in underground coal mines using diesel equipment not equipped with emission controls. The USBM and the Donaldson Co., Inc., Minneapolis, MN, have developed a low-temperature, disposable diesel exhaust filter (DDEF) for use on permissible diesel haulage vehicles equipped with waterbath exhaust conditioners. These were evaluated in three underground mines to determine their effectiveness inmore » reducing DEA concentrations. The DDEF reduced DEA concentrations from 70 to 90% at these mines. The usable life of the filter ranged from 10 to 32 h, depending on factors that affect DEA output, such as mine altitude, engine type, and duty-cycle. Cost per filter is approximately $40.« less
Trade Study of Excavation Tools and Equipment for Lunar Outpost Development and ISRU
NASA Astrophysics Data System (ADS)
Mueller, R. P.; King, R. H.
2008-01-01
The NASA Lunar Architecture Team (LAT) has developed a candidate architecture to establish a lunar outpost that includes in-situ resource utilization (ISRU). Outpost development requires excavation for landing and launch sites, roads, trenches, foundations, radiation and thermal shielding, etc. Furthermore, ISRU requires excavation as feed stock for water processing and oxygen production plants. The design environment for lunar excavation tools and equipment including low gravity, cost of launching massive equipment, limited power, limited size, high reliability, and extreme temperatures is significantly different from terrestrial excavation equipment design environment. Consequently, the lunar application requires new approaches to developing excavation tools and equipment in the context of a systems engineering approach to building a Lunar Outpost. Several authors have proposed interesting and innovative general excavation approaches in the literature, and the authors of this paper will propose adaptations and/or new excavation concepts specific to the Lunar Outpost. The requirements for excavation from the LAT architecture will be examined and quantified with corresponding figures of merit and evaluation criteria. This paper will evaluate the proposed approaches using traditional decision making with uncertainty techniques.
NASA Astrophysics Data System (ADS)
Matsumoto, Nobuhiro; Watanabe, Takuro; Maruyama, Masaaki; Horimoto, Yoshiyuki; Maeda, Tsuneaki; Kato, Kenji
2004-06-01
The gravimetric method is the most popular method for preparing reference gas mixtures with high accuracy. We have designed and manufactured novel mass measurement equipment for gravimetric preparation of reference gas mixtures. This equipment consists of an electronic mass-comparator with a maximum capacity of 15 kg and readability of 1 mg and an automatic cylinder exchanger. The structure of this equipment is simpler and the cost is much lower than a conventional mechanical knife-edge type large balance used for gravimetric preparation of primary gas mixtures in Japan. This cylinder exchanger can mount two cylinders alternatively on the weighing pan of the comparator. In this study, the performance of the equipment has been evaluated. At first, the linearity and repeatability of the mass measurement were evaluated using standard mass pieces. Then, binary gas mixtures of propane and nitrogen were prepared and compared with those prepared with the conventional knife-edge type balance. The comparison resulted in good consistency at the compatibility criterion described in ISO6143:2001.
NASA Astrophysics Data System (ADS)
Miao, Yongchun; Kang, Rongxue; Chen, Xuefeng
2017-12-01
In recent years, with the gradual extension of reliability research, the study of production system reliability has become the hot topic in various industries. Man-machine-environment system is a complex system composed of human factors, machinery equipment and environment. The reliability of individual factor must be analyzed in order to gradually transit to the research of three-factor reliability. Meanwhile, the dynamic relationship among man-machine-environment should be considered to establish an effective blurry evaluation mechanism to truly and effectively analyze the reliability of such systems. In this paper, based on the system engineering, fuzzy theory, reliability theory, human error, environmental impact and machinery equipment failure theory, the reliabilities of human factor, machinery equipment and environment of some chemical production system were studied by the method of fuzzy evaluation. At last, the reliability of man-machine-environment system was calculated to obtain the weighted result, which indicated that the reliability value of this chemical production system was 86.29. Through the given evaluation domain it can be seen that the reliability of man-machine-environment integrated system is in a good status, and the effective measures for further improvement were proposed according to the fuzzy calculation results.
Lack of maintenance of shortwave diathermy equipment has a negative impact on power output.
Guirro, Rinaldo Roberto de Jesus; Guirro, Elaine Caldeira de Oliveira; Alves de Sousa, Natanael Teixeira
2014-04-01
Although shortwave diathermy has been widely used by physiotherapists, there are a few studies assessing the performance of the equipment in use. The aim of the present study was to evaluate the procedures adopted by physiotherapists as users of shortwave diathermy continuous (CSWD), as well as to measure the power output and frequency of CSWD equipment. [Subjects and Methods] Twenty-three physical therapists were interviewed and 23 CSWD equipment were evaluated. Admeasurement was carried out by using a standard phantom to simulate the electrode-skin distance, which ranged from 0.5 to 3.0 cm. Data analysis was performed by using descriptive statistics, ANOVA, and a post-hoc Tukey's test or Pearson's correlation coefficient. [Results] The questionnaires showed that 48% of the interviewees use the correct electrode-skin distance, 70% use a single electrical outlet, and 35% use a grounded electrical outlet, and that 48% of the physiotherapy tables and 61% of the plinths were made of wood. However, only 13% of the interviewees perform yearly preventive maintenance. The highest power (95.56 W) was achieved at electrode-skin distances ranging from 1.0 to 1.5 cm, with distances of 2.5 cm and 3.0 cm being null in four and eight equipment, respectively. There was a negative correlation between power output and electrode-skin distance as well as between power output and purchase date. [Conclusion] The physiotherapists involved in this study had inadequate knowledge about the correct use of CSWD equipment, which may adversely affect its performance and patient safety.
48 CFR 215.404-71-4 - Facilities capital employed.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., and equipment, as derived in DD Form 1861, Contract Facilities Capital Cost of Money. (i) In addition... facilities capital, the allocated facilities capital attributable to the buildings and equipment of those... Equipment 17.5 10 to 25 (g) Evaluation criteria. (1) In evaluating facilities capital employed, the...
Soil compaction effects of forwarding and its relationship with 6- and 8-wheel drive machines
Fernando Seixas; Tim McDonald
1997-01-01
A study was done to determine the impact, if any, of a range of drive train options on the soil compaction effects of forwarders. The purpose of the study was to evaluate the cost of optional forwarder equipment versus its ability to reduce detrimental soil physical property changes. Tests were done on forwarders equipped with wide and narrow tires, rear steel tracks,...
Batista, W O; Navarro, M V T; Maia, A F
2013-12-01
Basically, all modalities of diagnostic radiology require phantoms suitable for dosimetric evaluations. New technologies frequently arise unaccompanied of tools for dosimetric evaluations and quality control. In this study, a low-cost phantom and a consequent proposed methodology for dosimetric evaluations in cone beam computed tomography (CBCT) were presented. The developed phantom has typical dimensions of the human face, was built in polymethyl methacrylate and filled with water. Three devices with different technological concepts were evaluated and a proposed index, kerma index-height product (PKIH), was defined as an option to the use of air kerma-area product. The results of this study show relatively uniform kerma profiles for scanners with field of views (FOVs) of large diameters and non-uniform for FOVs of small diameters. With regard to the values obtained for the kerma indexes, much higher values were found for the equipment FOVs with small diameter compared with the values of the two other equipment that have larger diameters. The results indicate that (1) there is a need for special phantoms for use in CBCT, (2) the use of P(KA) in the evaluation of protocols on different equipment can lead to false interpretations and (3) the new index is a suitable alternative for the use of P(KA) in CBCT.
DOT National Transportation Integrated Search
1978-01-01
This report explains the methods and equipment used to produce fluorescent, impregnated, polished, ultrathin sections of portland cement concrete. These sections are used in the study of the microstructure of concrete and are examined with a microsco...
ERIC Educational Resources Information Center
WADE, WARREN L.
TELEVISED INSTRUCTION IS WIDESPREAD, YET THERE EXISTS LITTLE QUALIFIED, IMPARTIAL INFORMATION EXPRESSED IN NONTECHNICAL TERMS (AS IN THIS REPORT), CONCERNING EQUIPMENT AND PERSONNEL STANDARDS, REQUIREMENT, AND COSTS, FOR SCHOOL ADMINISTRATORS TO CONSULT. EVALUATION OF THE MEDIUM'S POTENTIAL MUST BE BASED ON INFORMATION CONCERNING TELEVISION'S…
Sgalambro, Maria Luisa; Nataletti, Pietro; Ioppolo, Francesco; Bernetti, Andrea; Santilli, Valter
2012-01-01
Electro-medical equipment is widely used in order to treat bony and muscular disorders and some neurological disease in rehabilitation. However, the scientific evidence regarding the safety and efficacy of this equipment is meagre and contradictory. We have studied the subject, taking into account current regulations for the management and use of this electro-medical equipment. Following the criteria for Evidence Based Medicine, we have analysed the international literature so as to evaluate the evidence for physical energy in different clinical applications. Because the vast quantity of publications dealing with this material, priority was given to peer-reviewed articles and randomised trials. The publications were divided into categories according to disorder, so as to illustrate how some may provide positive proof whereas others require further study.
Chlorine tank car puncture resistance evaluation
DOT National Transportation Integrated Search
1992-07-01
Experimental studies have been conducted to evaluate the relative puncture resistance of DOT 105A500W (chlorine) tank cars and DOT 112J340W (propane) tank cars equipped with 1/2-inch steel head shields. These studies included a series of full- and 1/...
Safe patient handling perceptions and practices: a survey of acute care physical therapists.
Olkowski, Brian F; Stolfi, Angela M
2014-05-01
Acute care physical therapists are at risk for developing work-related musculoskeletal disorders (WMSDs) due to manual patient handling. Safe patient handling (SPH) reduces WMSDs caused by manual handling. The purpose of this study was to describe the patient handling practices of acute care physical therapists and their perceptions regarding SPH. Additionally, this study determined whether an SPH program influences the patient handling practices and perceptions regarding SPH of acute care physical therapists. Subscribers to the electronic discussion board of American Physical Therapy Association's Acute Care Section were invited to complete a survey questionnaire. The majority of respondents used SPH equipment and practices (91.1%), were confident using SPH equipment and practices (93.8%), agreed that evidence supports the use of SPH equipment and practices (87.0%), and reported the use of SPH equipment and practices is feasible (92.2%). Respondents at a facility with an SPH program were more likely to use SPH equipment and practices, have received training in the use of SPH equipment and practices, agree that the use of SPH equipment and practices is feasible, and feel confident using SPH equipment and practices. The study might not reflect the perceptions and practices of the population of acute care physical therapists. Acute care physical therapists are trained to use SPH equipment and practices, use SPH equipment and practices, and have positive perceptions regarding SPH. Acute care physical therapists in a facility with an SPH program are more likely to use SPH equipment and practices, receive training in SPH equipment and practices, and have positive perceptions regarding SPH. Quasi-regulatory organizations should incorporate SPH programs into their evaluative standards.
Contact Dermatitis to Personal Sporting Equipment in Youth.
Marzario, Barbara; Burrows, Dianne; Skotnicki, Sandy
2016-07-01
Contact dermatitis to personal sporting equipment in youth is poorly studied. To review the results of patch testing 6 youth to their sporting equipment in a dermatology general private practice from 2006 to 2011. A retrospective analysis of 6 youth aged 11 to 14 who were evaluated for chronic and persistent dermatitis occurring in relation to sports equipment was conducted. All patients were subjected to epicutaneous (patch) testing, which included some or all of the following: North American Contact Dermatitis Group (NACGD) series, textile series, rubber series, corticosteroid series, and raw material from the patients' own personal equipment. All cases had 1 or more positive patch test reactions to an allergen within the aforementioned series, and 3 subjects tested positive to their personal equipment in raw form. Allergic contact dermatitis, not irritant, was deemed the relevant cause of chronic dermatitis in 4 of the 6 patients due to positive reactions to epicutaneous tests and/or personal equipment. The utility of testing to patients' own sporting equipment was shown to be of additional value and should be considered when patch testing for contact allergy to sporting equipment. © The Author(s) 2015.
Definition study for an extended manned test of a regenerative life support system
NASA Technical Reports Server (NTRS)
1971-01-01
A program was defined which consists of extended ground-based manned tests of regenerative life support systems. The tests are to evaluate prototypes of advanced life support systems under operational, integrated conditions, thus providing data for the design of efficient environmental control and life support systems for use in long-duration space missions. The requirements are defined for test operations to provide a simulation of an orbiting space laboratory. The features of Phase A and B programs are described. These tests use proven backup equipment to ensure successful evaluation of the advanced subsystems. A pre-tests all-systems checkout period is provided to minimize equipment problems during extended testing and to familiarize all crew and operating staff members with test equipment and procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, P.; Putkovich, R.P.
1981-07-01
A study was conducted of the requirements for and technologies applicable to power conditioning equipment in residential solar photovoltaic systems. A survey of companies known or thought to manufacture power conditioning equipment was conducted to asses the technology. Technical issues regarding ac and dc interface requirements were studied. A baseline design was selected to be a good example of existing technology which would not need significant development effort for its implementation. Alternative technologies are evaluated to determine which meet the baseline specification, and their costs and losses are evaluated. Areas in which cost improvements can be obtained are studied, andmore » the three best candidate technologies--the current-sourced converter, the HF front end converter, and the programmed wave converter--are compared. It is concluded that the designs investigated will meet, or with slight improvement could meet, short term efficiency goals. Long term efficiency goals could be met if an isolation transformer were not required in the power conditioning equipment. None of the technologies studied can meet cost goals unless further improvements are possible. (LEW)« less
30 CFR 18.91 - Electric equipment for which field approvals will be issued.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric equipment for which field approvals... OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Field Approval of Electrically Operated Mining Equipment § 18.91 Electric equipment...
30 CFR 18.91 - Electric equipment for which field approvals will be issued.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric equipment for which field approvals... OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Field Approval of Electrically Operated Mining Equipment § 18.91 Electric equipment...
NASA Astrophysics Data System (ADS)
Kozhushko, A. A.; Pahotin, A. N.; Mal'tsev, V. N.; Bojarnikova, L. V.; Stepanova, E. P.
2018-04-01
The technology of carrying out various geophysical studies of oil wells using a carrying well-logging cable for the delivery of geophysical instruments and equipment is considered in the article. The relevance of the topic results from the need to evaluate the effect of well-logging cable stretching in the well under the influence of its own mass and mass of geophysical instruments and equipment on the accuracy and adequacy geophysical studies. Calculation formulas for determining the well-logging cable stretching under the influence of the geophysical tools and equipment mass without taking into account and taking into account the influence of the carrying well-logging cable mass are also presented. For three types of carrying well-logging cables, calculations were made of their stretching in the oil well under the mass of geophysical instruments and equipment and its own mass, depending on the depth of the investigated well. The analysis of the obtained results made it possible to numerically evaluate the extension of the carrying well-logging cable depending on the depth of the investigated well and by correcting the obtained results it allows to provide the required depth accuracy and reliability of the interpreted results of the geophysical studies.
Effect of basic laparoscopic skills courses on essential knowledge of equipment.
van Hove, P Diederick; Verdaasdonk, Emiel G G; van der Harst, Erwin; Jansen, Frank Willem; Dankelman, Jenny; Stassen, Laurents P S
2012-12-01
This study aims to evaluate the effect of laparoscopic skills courses on the knowledge of laparoscopic equipment. A knowledge test on laparoscopic equipment was developed, and participants of 3 separate basic laparoscopic skills courses in the Netherlands completed the test at the beginning and end of these courses. All lectures and demonstrations during the courses were recorded on video to assess the matching of its contents with the items in the test. As a reference, the test was also completed by a group of laparoscopic experts by e-mail. In total, 36 participants (64.3%) completed both the pretest and posttest. Overall, the mean test score improved from 60.4% of the maximum possible score for the pretest to 68.4% for the posttest. There were no significant differences in test scores between the 3 separate courses. However, the actual content varied among the courses. The correspondence of the test items with the course content varied from 47% to 69%. Although 30% of the participants had already received training for laparoscopic equipment in their own hospital, 92.5% wanted to receive more training. 28 experts completed the test with a mean score of 75.7%, which was significantly better than the posttest score of the course participants. The laparoscopic skills courses evaluated in this study had a modest positive effect on the acquisition of knowledge about laparoscopic equipment. Variance exists among their contents.
Robotic equipment malfunction during robotic prostatectomy: a multi-institutional study.
Lavery, Hugh J; Thaly, Rahul; Albala, David; Ahlering, Thomas; Shalhav, Arieh; Lee, David; Fagin, Randy; Wiklund, Peter; Dasgupta, Prokar; Costello, Anthony J; Tewari, Ashutosh; Coughlin, Geoff; Patel, Vipul R
2008-09-01
Robotic-assisted laparoscopic prostatectomy (RALP) is growing in popularity as a treatment option for prostate cancer. As a new technology, little is known regarding the reliability of the da Vinci robotic system. Intraoperative robotic equipment malfunction may force the surgeon to convert the procedure to an open or pure laparoscopic procedure, or possibly even abort the procedure. We report the first large-scale, multi-institutional review of robotic equipment malfunction. A questionnaire was designed to evaluate the rate of perioperative robotic malfunction during RALP. High-volume, experienced surgeons were asked to complete this evaluation based on the analysis of their data. Questions included the overall number of RALPs performed, the number of equipment malfunctions, the number of procedures that had to be converted or aborted, and the part of the robotic system that malfunctioned. Eleven institutions participated in the study with a median surgeon volume of 700 cases, accounting for a total case volume of 8240. Critical failure occurred in 34 cases (0.4%) leading to the cancellation of 24 cases prior to the procedure, and the conversion to two laparoscopic and eight open procedures. The most common components of the robot to malfunction were the arms and optical system. Critical robotic equipment malfunction is extremely rare in institutions that perform high volumes of RALPs, with a nonrecoverable malfunction rate of only 0.4%.
Evaluations of in-use emission factors from off-road construction equipment
NASA Astrophysics Data System (ADS)
Cao, Tanfeng; Durbin, Thomas D.; Russell, Robert L.; Cocker, David R.; Scora, George; Maldonado, Hector; Johnson, Kent C.
2016-12-01
Gaseous and particle emissions from construction engines contribute an important fraction of the total air pollutants released into the atmosphere and are gaining increasing regulatory attention. Robust quantification of nitrogen oxides (NOx) and particulate matter (PM) emissions are necessary to inventory the contribution of construction equipment to atmospheric loadings. Theses emission inventories require emissions factors from construction equipment as a function of equipment type and modes of operation. While the development of portable emissions measurement systems (PEMS) has led to increased studies of construction equipment emissions, emissions data are still much more limited than for on-road vehicles. The goal of this research program was to obtain accurate in-use emissions data from a test fleet of newer construction equipment (model year 2002 or later) using a Code of Federal Requirements (CFR) compliant PEMS system. In-use emission measurements were made from twenty-seven pieces of construction equipment, which included four backhoes, six wheel loaders, four excavators, two scrapers (one with two engines), six bulldozers, and four graders. The engines ranged in model year from 2003 to 2012, in rated horsepower (hp) from 92 to 540 hp, and in hours of operation from 24 to 17,149 h. This is the largest study of off-road equipment emissions using 40 CFR part 1065 compliant PEMS equipment for all regulated gaseous and particulate emissions.
Indoor pollutants emitted by office equipment: A review ofreported data and information needs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Destaillats, Hugo; Maddalena, Randy L.; Singer, Brett C.
2007-02-01
There is concern that potentially harmful pollutants may be emitted from office equipment. Although office equipment has been a focal point for governmental efforts to promote energy efficiency through programs such as the US EPA's Energy Star, little is known about the relationship between office equipment use and indoor air quality, and information on pollutant emissions is sparse. In this review, we summarize available information on emission rates and/or ambient concentrations of various pollutants that are related to office equipment use. Experimental methods used in the characterization of emissions are briefly described. The office equipment evaluated in this review includesmore » computers (desktops and notebooks), printers (laser, ink-jet and all-in-one machines) and photocopy machines. Reported emission rates of the following pollutant groups are summarized: volatile organic chemicals (VOCs), ozone, particulate matter and several semivolatile organic chemicals (SVOCs). The latter include phthalate esters, brominated flame retardants, organophosphate flame retardants and polycyclic aromatic hydrocarbons (PAHs). We also review studies reporting airborne concentrations in indoor environments where office equipment was present and thought to be a significant contributor to the total pollutant burden (offices, residences, schools, electronics recycling plants). For certain pollutants, such as organophosphate flame retardants, the link between emission by office equipment and indoor air concentrations is relatively well established. However, indoor VOCs, ozone, PAHs and phthalate esters can originate from a variety of sources, and their source apportionment is less straightforward. This literature review identifies substances of toxicological significance, with the purpose of serving as a guide to evaluate their potential importance with respect to human exposures.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ambs, J.L.; Cantrell, B.K.; Watts, W.F.
1994-01-01
The U.S. Bureau of Mines (USBM) Diesel Research Program emphasizes the development and evaluation of emission control devices to reduce exposure of miners to diesel exhaust pollutants. Studies by the USBM have shown that diesel exhaust aerosol (DEA) contributes a substantial portion of the respirable aerosol in underground coal mining using diesel equipment not equipped with emission controls. The USBM and the Donaldson Co., Inc., Minneapolis, MN, have developed a low-temperature, disposable diesel exhaust filter (DDEF) for use on permissible diesel haulage vehicles equipped with waterban exhaust conditioners. These were evaluated in three underground mines to determine their effectiveness inmore » reducing DEA concentrations. The DDEF reduced DEA concentrations from 70 to 90 pct at these mines. The usable life of the filter ranged from 10 to 32 h, depending on factors that affect DEA output, such as mine altitude, engine type, and duty-cycle. Cost per filter is approximately $40.« less
Orthodontics for the dog. Bite evaluation, basic concepts, and equipment.
Ross, D L
1986-09-01
Evaluation of canine occlusion (an occlusal evaluation table is included), growth patterns of the head, basic concepts of orthodontics such as how teeth move, length of treatment, and limits to movements, and equipment and materials are considered in this article.
Injury survey of a non-traditional 'soft-edged' trampoline designed to lower equipment hazards.
Eager, David B; Scarrott, Carl; Nixon, Jim; Alexander, Keith
2013-01-01
In Australia trampolines contribute one quarter of all childhood play equipment injuries. The objective of this study was to gather and evaluate injury data from a non-traditional, 'soft-edged', consumer trampoline, where the design aimed to minimise injuries from the equipment and from falling off. The manufacturer of the non-traditional trampoline provided the University of Technology Sydney with their Australian customer database. The study involved surveys in Queensland and New South Wales, between May 2007 and March 2010. Initially injury data was gathered by a phone interview pilot study, then in the full study, through an email survey. The 3817 respondents were the carers of child users of the 'soft-edge' trampolines. Responses were compared with Australian and US emergency department data. In both countries the proportion of injuries caused by the equipment and falling off was compared with the proportion caused by the jumpers to themselves or each other. The comparisons showed a significantly lower proportion resulted from falling-off or hitting the equipment for this design when compared to traditional trampolines, both in Australia and the US. This research concludes that equipment-induced and falling-off injuries, the more severe injuries on traditional trampolines, can be significantly reduced with appropriate trampoline design.
Implementation of testing equipment for asphalt materials.
DOT National Transportation Integrated Search
2009-05-01
Three new automated methods for related asphalt testing were evaluated under this study in an effort to save time and reduce variability in testing. The Therymolyne SSDetect, Instrotek CoreLok and Instrotek CoreDry devices were evaluated throughout t...
Implementation of Testing Equipment for Asphalt Materials
DOT National Transportation Integrated Search
2009-05-01
Three new automated methods for related asphalt testing were evaluated under this study in an effort to save time and reduce variability in testing. The Therymolyne SSDetect, Instrotek CoreLok and Instrotek CoreDry devices were evaluated throughout t...
DOT National Transportation Integrated Search
2010-03-01
Objectives: Evaluate the usefulness of the dynamic modulus and flow number tests in moisture-susceptibility evaluation, Compare the results to those achieved using the AASHTO T 283 test, Study the effect of different methods of sample conditioning an...
1994-02-01
Respiratory Protection (AERP) and associated clothing and equipment. Two subjects each carried out simulated tanker/transport and fighter/attack scenarios. No...AD A277 288 N•.• AL-TP-1 993-0014 ý’vI~~I~ 11~ II~I AIRCREW EYE/ RESPIRATORY PROTECTION (AERP): 16-HOUR EXTENDED WEAR EVALUATION OF R CHEMICAL...S. FUNDING NUMBERS ’Aircrew Eye/ Respiratory Protection (AERP): 16-Hour Extended PE - 62202F Wear Evaluation of Chemical Protective Equipment PR
Evaluation of equipment and methods to map lost circulation zones in geothermal wells
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, W.J.; Leon, P.A.; Pittard, G.
A study and evaluation of methods to locate, characterize, and quantify lost circulation zones are described. Twenty-five methods of mapping and quantifying lost circulation zones were evaluated, including electrical, acoustical, mechanical, radioactive, and optical systems. Each tool studied is described. The structured, numerical evaluation plan, used as the basis for comparing the 25 tools, and the resulting ranking among the tools is presented.
The heat is on: room temperature affects laboratory equipment--an observational study.
Butler, Julia M; Johnson, Jane E; Boone, William R
2013-10-01
To evaluate the effect of ambient room temperature on equipment typically used in in vitro fertilization (IVF). We set the control temperature of the room to 20 °C (+/-0.3) and used CIMScan probes to record temperatures of the following equipment: six microscope heating stages, four incubators, five slide warmers and three heating blocks. We then increased the room temperature to 26 °C (+/-0.3) or decreased it to 17 °C (+/-0.3) and monitored the same equipment again. We wanted to determine what role, if any, changing room temperature has on equipment temperature fluctuation. There was a direct relationship between room temperature and equipment temperature stability. When room temperature increased or decreased, equipment temperature reacted in a corresponding manner. Statistical differences between equipment were found when the room temperature changed. What is also noteworthy is that temperature of equipment responded within 5 min to a change in room temperature. Clearly, it is necessary to be aware of the affect of room temperature on equipment when performing assisted reproductive procedures. Room and equipment temperatures should be monitored faithfully and adjusted as frequently as needed, so that consistent culture conditions can be maintained. If more stringent temperature control can be achieved, human assisted reproduction success rates may improve.
Fluid handling 2: Surgical applications
NASA Technical Reports Server (NTRS)
Billica, Roger; Young, John; Rushing, Doug; Kizzee, Victor D.
1991-01-01
The methods proposed for managing fluids and particulate debris during minor surgery on Space Station Freedom (SSF) were investigated and demonstrated. A KC-135 parabolic flight test was performed, in which the flight followed the standard 40 parabola profile with 20 to 25 seconds in near-zero gravity in each parabola. The equipment (suction and laminar flow device) was evaluated. While this equipment performed satisfactorily previously in the dental simulation, the purpose of the current flight was to reconfigure the equipment in support of a minor surgical situation in order to evaluate its efficacy and establish clear requirements for the actual flight hardware. To accomplish the study the Health Maintenance Facility medical restraint system was deployed as for surgical use and mannequin suture arm was restrained to its surface. The surgical area was established as for performing minor surgery with standard tray and suture instruments employed.
Post Occupancy Evaluation of Educational Buildings and Equipment.
ERIC Educational Resources Information Center
Watson, Chris
1997-01-01
Details the post occupancy evaluation (POE) process for public buildings. POEs are used to improve design and optimize educational building and equipment use. The evaluation participants, the method used, the results and recommendations, model schools, and classroom alterations using POE are described. (9 references.) (RE)
Impact of Installation Faults on Heat Pump Performance
Hourahan, Glenn; Baxter, Van D.
2015-01-01
Numerous studies and surveys indicate that typically-installed HVAC equipment operate inefficiently and waste considerable energy due to varied installation errors (faults) such as improper refrigerant charge, incorrect airflow, oversized equipment, and leaky ducts. This article summarizes the results of a large United States (U.S.) experimental/analytical study (U.S. contribution to IEA HPP Annex 36) of the impact that different faults have on the performance of an air-source heat pump (ASHP) in a typical U.S. single-family house. It combines building effects, equipment effects, and climate effects in an evaluation of the faults impact on seasonal energy consumption through simulations of the house/ASHPmore » pump system.« less
Space station wardroom habitability and equipment study
NASA Technical Reports Server (NTRS)
Nixon, David; Miller, Christopher; Fauquet, Regis
1989-01-01
Experimental designs in life-size mock-up form for the wardroom facility for the Space Station Habitability Module are explored and developed. In Phase 1, three preliminary concepts for the wardroom configuration are fabricated and evaluated. In Phase 2, the results of Phase 1 are combined with a specific range of program design requirements to provide the design criteria for the fabrication of an innovative medium-fidelity mock-up of a wardrobe configuration. The study also focuses on the design and preliminary prototyping of selected equipment items including crew exercise compartments, a meal/meeting table and a portable workstation. Design criteria and requirements are discussed and documented. Preliminary and final mock-ups and equipment prototypes are described and illustrated.
Evaluation of the intelligent cruise control system : volume 1 : study results
DOT National Transportation Integrated Search
1999-10-01
The Intelligent Cruise Control (ICC) system evaluation was based on an ICC Field Operational Test (FOT) performed in Michigan. The FOT involved 108 volunteers recruited to drive ten ICC-equipped Chrysler Concordes. Testing was initiated in July 1996 ...
Moore, Susan M; Porter, William L; Dempsey, Patrick G
2009-01-01
The objective of this study was to evaluate the circumstances leading to fall from equipment injuries in the mining industry. The 2006 and 2007 Mine Safety and Health Administration annual injury databases were utilized for this study whereby the injury narrative, nature of injury, body part injured, mine type, age at injury, and days lost were evaluated for each injury. The majority of injuries occurred at surface mining facilities (approximately 60%) with fractures and sprains/strains being the most common injuries occurring to the major joints of the body. Nearly 50% of injuries occurred during ingress/egress, predominantely during egress, and approximately 25% of injuries occurred during maintenance tasks. The majority of injuries occurred in relation to large trucks, wheel loaders, dozers, and conveyors/belts. The severity of injury was independent of age and the median days lost was seven days; however, there was a large range in severity. From the data obtained in this study, several different research areas have been identified for future work, which include balance and stability control when descending ladders and equipment design for maintenance tasks.
Evaluation of 3-D laser scanning equipment : 2016 interim report.
DOT National Transportation Integrated Search
2017-05-01
As a follow-up to ICT Project R27-030, Evaluation of 3-D Laser Scanning, this report provides findings of an evaluation of 3-D laser : scanning equipment to determine the tangible costs versus benefits and the manpower savings realized by using the e...
Evaluation of 3-D Laser Scanning Equipment : 2018 Final Report
DOT National Transportation Integrated Search
2018-05-01
As a follow-up to ICT Project R27-030, Evaluation of 3-D Laser Scanning, this report provides findings of an evaluation of 3-D laser scanning equipment to determine the tangible costs versus benefits and the manpower savings realized by using the equ...
Evaluation of the Steris Sensitive Equipment Decontamination (SED) Apparatus on a 463L Pallet
2007-09-01
to decontaminate representative articles of sensitive equipment and operationally relevant materials for biological-warfare agent surrogate... Articles of Sensitive Equipment .................................................................. 25 2.9 Sensitive Equipment Inspection...45 3.6.2 Test Article Initial Inspection .............................................................. 47 3.6.3 Test
Multi-kilowatt modularized spacecraft power processing system development
NASA Technical Reports Server (NTRS)
Andrews, R. E.; Hayden, J. H.; Hedges, R. T.; Rehmann, D. W.
1975-01-01
A review of existing information pertaining to spacecraft power processing systems and equipment was accomplished with a view towards applicability to the modularization of multi-kilowatt power processors. Power requirements for future spacecraft were determined from the NASA mission model-shuttle systems payload data study which provided the limits for modular power equipment capabilities. Three power processing systems were compared to evaluation criteria to select the system best suited for modularity. The shunt regulated direct energy transfer system was selected by this analysis for a conceptual design effort which produced equipment specifications, schematics, envelope drawings, and power module configurations.
NASA Astrophysics Data System (ADS)
Mihlan, G. J.; Ungers, L. J.; Smith, R. K.; Mitchell, R. I.; Jones, J. H.
1983-05-01
A preliminary control technology assessment survey was conducted at the facility which manufactures N-channel metal oxide semiconductor (NMOS) integrated circuits. The facility has industrial hygiene review procedures for evaluating all new and existing process equipment. Employees are trained in safety, use of personal protective equipment, and emergency response. Workers potentially exposed to arsenic are monitored for urinary arsenic levels. The facility should be considered a candidate for detailed study based on the diversity of process operations encountered and the use of state-of-the-art technology and process equipment.
Anechoic Chambers: Aerospace Applications. (Latest Citations from the Aerospace Database)
NASA Technical Reports Server (NTRS)
1996-01-01
The bibliography contains citations concerning the design, development, performance, and applications of anechoic chambers in the aerospace industry. Anechoic chamber testing equipment, techniques for evaluation of aerodynamic noise, microwave and radio antennas, and other acoustic measurement devices are considered. Shock wave studies on aircraft models and components, electromagnetic measurements, jet flow studies, and antenna radiation pattern measurements for industrial and military aerospace equipment are discussed. (Contains 50-250 citations and includes a subject term index and title list.)
Anechoic Chambers: Aerospace Applications. (Latest Citations from the Aerospace Database)
NASA Technical Reports Server (NTRS)
1995-01-01
The bibliography contains citations concerning the design, development, performance, and applications of anechoic chambers in the aerospace industry. Anechoic chamber testing equipment, techniques for evaluation of aerodynamic noise, microwave and radio antennas, and other acoustic measurement devices are considered. Shock wave studies on aircraft models and components, electromagnetic measurements, jet flow studies, and antenna radiation pattern measurements for industrial and military aerospace equipment are discussed. (Contains 50-250 citations and includes a subject term index and title list.)
NASA Technical Reports Server (NTRS)
1978-01-01
Alternate level 4 integration approaches were synthesized and evaluated to establish the most cost effective experiment integration approach. Program baseline system trade studies are described, as well as Spacelab equipment utilization. Programmatic analysis of the baseline program was evaluated; the 2/3 and 1/3 traffic models were also considered.
40 CFR 63.2994 - How do I verify the performance of monitoring equipment?
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring equipment. (2) Conduct a performance evaluation of the continuous monitoring system (CMS...-specific performance evaluation plan, conduct of the performance evaluation, and reporting of performance... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I verify the performance of...
Comparison of MERV 16 and HEPA filters for cab filtration of underground mining equipment.
Cecala, A B; Organiscak, J A; Noll, J D; Zimmer, J A
2016-08-01
Significant strides have been made in optimizing the design of filtration and pressurization systems used on the enclosed cabs of mobile mining equipment to reduce respirable dust and provide the best air quality to the equipment operators. Considering all of the advances made in this area, one aspect that still needed to be evaluated was a comparison of the efficiencies of the different filters used in these systems. As high-efficiency particulate arrestance (HEPA) filters provide the highest filtering efficiency, the general assumption would be that they would also provide the greatest level of protection to workers. Researchers for the U.S. National Institute for Occupational Safety and Health (NIOSH) speculated, based upon a previous laboratory study, that filters with minimum efficiency reporting value, or MERV rating, of 16 may be a more appropriate choice than HEPA filters in most cases for the mining industry. A study was therefore performed comparing HEPA and MERV 16 filters on two kinds of underground limestone mining equipment, a roof bolter and a face drill, to evaluate this theory. Testing showed that, at the 95-percent confidence level, there was no statistical difference between the efficiencies of the two types of filters on the two kinds of mining equipment. As the MERV 16 filters were less restrictive, provided greater airflow and cab pressurization, cost less and required less-frequent replacement than the HEPA filters, the MERV 16 filters were concluded to be the optimal choice for both the roof bolter and the face drill in this comparative-analysis case study. Another key finding of this study is the substantial improvement in the effectiveness of filtration and pressurization systems when using a final filter design.
Comparison of MERV 16 and HEPA filters for cab filtration of underground mining equipment
Cecala, A.B.; Organiscak, J.A.; Noll, J.D.; Zimmer, J.A.
2016-01-01
Significant strides have been made in optimizing the design of filtration and pressurization systems used on the enclosed cabs of mobile mining equipment to reduce respirable dust and provide the best air quality to the equipment operators. Considering all of the advances made in this area, one aspect that still needed to be evaluated was a comparison of the efficiencies of the different filters used in these systems. As high-efficiency particulate arrestance (HEPA) filters provide the highest filtering efficiency, the general assumption would be that they would also provide the greatest level of protection to workers. Researchers for the U.S. National Institute for Occupational Safety and Health (NIOSH) speculated, based upon a previous laboratory study, that filters with minimum efficiency reporting value, or MERV rating, of 16 may be a more appropriate choice than HEPA filters in most cases for the mining industry. A study was therefore performed comparing HEPA and MERV 16 filters on two kinds of underground limestone mining equipment, a roof bolter and a face drill, to evaluate this theory. Testing showed that, at the 95-percent confidence level, there was no statistical difference between the efficiencies of the two types of filters on the two kinds of mining equipment. As the MERV 16 filters were less restrictive, provided greater airflow and cab pressurization, cost less and required less-frequent replacement than the HEPA filters, the MERV 16 filters were concluded to be the optimal choice for both the roof bolter and the face drill in this comparative-analysis case study. Another key finding of this study is the substantial improvement in the effectiveness of filtration and pressurization systems when using a final filter design. PMID:27524838
DOT National Transportation Integrated Search
1966-12-01
The primary objective of this study was to evaluate the gyratory kneading compactor and to investigate the possibilities and capabilities of this type of equipment. : Curves were developed for six different asphaltic concrete mixes with varying compa...
A simple test procedure for evaluating low temperature crack resistance of asphalt concrete.
DOT National Transportation Integrated Search
2009-11-01
The current means of evaluating the low temperature cracking resistance of HMA relies on extensive test : methods that require assumptions about material behaviors and the use of complicated loading equipment. The purpose : of this study was to devel...
DOT National Transportation Integrated Search
1998-05-01
Recent technological advances in computer hardware, software, and image processing have led to the development of automated license plate reading equipment. This equipment has primarily been developed for enforcement and security applications, such a...
NASA Technical Reports Server (NTRS)
Maronde, R. G.
1980-01-01
The Ku-band test equipment, known as the Deliverable System Test equipment (DSTE), is reviewed and evaluated. The DSTE is semiautomated and computer programs were generated for 14 communication mode tests and 17 radar mode tests. The 31 test modules provide a good cross section of tests with which to exercise the Ku-band system; however, it is very limited when being used to verify Ku-band system performance. More detailed test descriptions are needed, and a major area of concern is the DSTE sell-off procedure which is inadequate.
SLOPE STABILITY EVALUATION AND EQUIPMENT SETBACK DISTANCES FOR BURIAL GROUND EXCAVATIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
MCSHANE DS
2010-03-25
After 1970 Transuranic (TRU) and suspect TRU waste was buried in the ground with the intention that at some later date the waste would be retrieved and processed into a configuration for long term storage. To retrieve this waste the soil must be removed (excavated). Sloping the bank of the excavation is the method used to keep the excavation from collapsing and to provide protection for workers retrieving the waste. The purpose of this paper is to document the minimum distance (setback) that equipment must stay from the edge of the excavation to maintain a stable slope. This evaluation examinesmore » the equipment setback distance by dividing the equipment into two categories, (1) equipment used for excavation and (2) equipment used for retrieval. The section on excavation equipment will also discuss techniques used for excavation including the process of benching. Calculations 122633-C-004, 'Slope Stability Analysis' (Attachment A), and 300013-C-001, 'Crane Stability Analysis' (Attachment B), have been prepared to support this evaluation. As shown in the calculations the soil has the following properties: Unit weight 110 pounds per cubic foot; and Friction Angle (natural angle of repose) 38{sup o} or 1.28 horizontal to 1 vertical. Setback distances are measured from the top edge of the slope to the wheels/tracks of the vehicles and heavy equipment being utilized. The computer program utilized in the calculation uses the center of the wheel or track load for the analysis and this difference is accounted for in this evaluation.« less
NASA Astrophysics Data System (ADS)
Guo, Lijuan; Yan, Haijun; Hao, Yongqi; Chen, Yun
2018-01-01
With the power supply level of urban power grid toward high reliability development, it is necessary to adopt appropriate methods for comprehensive evaluation of existing equipment. Considering the wide and multi-dimensional power system data, the method of large data mining is used to explore the potential law and value of power system equipment. Based on the monitoring data of main transformer and the records of defects and faults, this paper integrates the data of power grid equipment environment. Apriori is used as an association identification algorithm to extract the frequent correlation factors of the main transformer, and the potential dependence of the big data is analyzed by the support and confidence. Then, the integrated data is analyzed by PCA, and the integrated quantitative scoring model is constructed. It is proved to be effective by using the test set to validate the evaluation algorithm and scheme. This paper provides a new idea for data fusion of smart grid, and provides a reference for further evaluation of big data of power grid equipment.
Implementation research to improve quality of maternal and newborn health care, Malawi.
Brenner, Stephan; Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela
2017-07-01
To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities' essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants' adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care.
Digital mobile telephones and interference of ophthalmic equipment.
Ang, G S; Lian, P; Ng, W S; Whyte, I; Ong, J M
2007-01-01
To assess the effect of mobile telephone electromagnetic interference on electronic ophthalmic equipment. Prospective audit with mobile telephones placed at distances of 3 m, 1 m, and 30 cm from, and in contact with, electronic ophthalmic equipment. Any interruption or cessation of the function of the ophthalmic device was assessed with the mobile telephones in standby, and in dialling or receiving modes. Any alterations of displayed digital figures or numbers were also assessed. A total of 23 electronic ophthalmic devices in two hospital ophthalmology outpatient departments were evaluated. All six mobile telephones used, and 22 (95.7%) of the 23 ophthalmic equipment evaluated had the Conformité Européene (CE) mark. No device showed any interruption or cessation of function. There were no alterations of displayed digital figures or numbers. The only effect of any kind was found with four instruments (1 non-CE marked), where there was temporary flickering on the screen, and only occurred when the mobile telephones were dialling or receiving at a distance of 30 cm or less from the instruments. This study shows that among the electronic ophthalmic devices tested, none suffered failure or interruption of function, from mobile telephone interference. Although not comprehensive for all ophthalmic equipment, the results question the need for a complete ban of mobile telephones in ophthalmic departments. It highlights the need for a controlled, objectively measured study of the clinically relevant effects of mobile telephones in the ophthalmology outpatient setting.
Performance of on-site Medical waste disinfection equipment in hospitals of Tabriz, Iran
Taghipour, Hassan; Alizadeh, Mina; Dehghanzadeh, Reza; Farshchian, Mohammad Reza; Ganbari, Mohammad; Shakerkhatibi, Mohammad
2016-01-01
Background: The number of studies available on the performance of on-site medical waste treatment facilities is rare, to date. The aim of this study was to evaluate the performance of onsite medical waste treatment equipment in hospitals of Tabriz, Iran. Methods: A various range of the on-site medical waste disinfection equipment (autoclave, chemical disinfection, hydroclave, and dry thermal treatment) was considered to select 10 out of 22 hospitals in Tabriz to be included in the survey. The apparatus were monitored mechanically, chemically, and biologically for a six months period in all of the selected hospitals. Results: The results of the chemical monitoring (Bowie-Dick tests) indicated that 38.9% of the inspected autoclaves had operational problems in pre-vacuum, air leaks, inadequate steam penetration into the waste, and/or vacuum pump. The biological indicators revealed that about 55.55% of the samples were positive. The most of applied devices were not suitable for treating anatomical, pharmaceutical, cytotoxic, and chemical waste. Conclusion: Although on-site medical waste treating facilities have been installed in all the hospitals, the most of infectious-hazardous medical waste generated in the hospitals were deposited into a municipal solid waste landfill, without enough disinfection. The responsible authorities should stringently inspect and evaluate the operation of on-site medical waste treating equipment. An advanced off-site central facility with multi-treatment and disinfection equipment and enough capacity is recommended as an alternative. PMID:27766238
Performance of on-site Medical waste disinfection equipment in hospitals of Tabriz, Iran.
Taghipour, Hassan; Alizadeh, Mina; Dehghanzadeh, Reza; Farshchian, Mohammad Reza; Ganbari, Mohammad; Shakerkhatibi, Mohammad
2016-01-01
Background: The number of studies available on the performance of on-site medical waste treatment facilities is rare, to date. The aim of this study was to evaluate the performance of onsite medical waste treatment equipment in hospitals of Tabriz, Iran. Methods: A various range of the on-site medical waste disinfection equipment (autoclave, chemical disinfection, hydroclave, and dry thermal treatment) was considered to select 10 out of 22 hospitals in Tabriz to be included in the survey. The apparatus were monitored mechanically, chemically, and biologically for a six months period in all of the selected hospitals. Results: The results of the chemical monitoring (Bowie-Dick tests) indicated that 38.9% of the inspected autoclaves had operational problems in pre-vacuum, air leaks, inadequate steam penetration into the waste, and/or vacuum pump. The biological indicators revealed that about 55.55% of the samples were positive. The most of applied devices were not suitable for treating anatomical, pharmaceutical, cytotoxic, and chemical waste. Conclusion: Although on-site medical waste treating facilities have been installed in all the hospitals, the most of infectious-hazardous medical waste generated in the hospitals were deposited into a municipal solid waste landfill, without enough disinfection. The responsible authorities should stringently inspect and evaluate the operation of on-site medical waste treating equipment. An advanced off-site central facility with multi-treatment and disinfection equipment and enough capacity is recommended as an alternative.
NASA Technical Reports Server (NTRS)
1974-01-01
The task phase concerned with the requirements, design, and planning studies for the carry-on laboratory (COL) began with a definition of biomedical research areas and candidate research equipment, and then went on to develop conceptual layouts for COL which were each evaluated in order to arrive at a final conceptual design. Each step in this design/evaluation process concerned itself with man/systems integration research and hardware, and life support and protective systems research and equipment selection. COL integration studies were also conducted and include attention to electrical power and data management requirements, operational considerations, and shuttle/Spacelab interface specifications. A COL program schedule was compiled, and a cost analysis was finalized which takes into account work breakdown, annual funding, and cost reduction guidelines.
An infrared procedure for evaluation of wet bath or dry gas calibration.
DOT National Transportation Integrated Search
1996-09-01
The National Highway Traffic Safety Administration maintains Conforming Products Lists for police breath alcohol testing equipment. Equipment submitted by manufacturers for inclusion on the Lists are first evaluated at Volpe National Transportation S...
Skylab astronaut life support assembly
NASA Technical Reports Server (NTRS)
Brown, J. T.
1972-01-01
A comparative study was performed to define an optimum portable life support system for suited operations inside and outside the Skylab Program. Emphasis was placed on utilization of qualified equipment, modified versions of qualified equipment, and new systems made up to state-of-the-art components. Outlined are the mission constraints, operational modes, and evaluation ground rules by which the Skylab portable life support system was selected and the resulting design.
30 CFR 75.1914 - Maintenance of diesel-powered equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... written standard operating procedures for such testing and evaluation that specify the following: (1) The... MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75... the equipment is operated. (d) The intake air filter on diesel-powered equipment shall be replaced or...
30 CFR 75.1914 - Maintenance of diesel-powered equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... written standard operating procedures for such testing and evaluation that specify the following: (1) The... MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75... the equipment is operated. (d) The intake air filter on diesel-powered equipment shall be replaced or...
30 CFR 75.1914 - Maintenance of diesel-powered equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... written standard operating procedures for such testing and evaluation that specify the following: (1) The... MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75... the equipment is operated. (d) The intake air filter on diesel-powered equipment shall be replaced or...
30 CFR 75.1914 - Maintenance of diesel-powered equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... written standard operating procedures for such testing and evaluation that specify the following: (1) The... MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75... the equipment is operated. (d) The intake air filter on diesel-powered equipment shall be replaced or...
30 CFR 75.1914 - Maintenance of diesel-powered equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... written standard operating procedures for such testing and evaluation that specify the following: (1) The... MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75... the equipment is operated. (d) The intake air filter on diesel-powered equipment shall be replaced or...
30 CFR 18.4 - Electrical equipment for which approval is issued.
Code of Federal Regulations, 2010 CFR
2010-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES General Provisions § 18.4 Electrical equipment for which approval is issued. An approval will be issued... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electrical equipment for which approval is...
76 FR 68376 - Recoupment of Nonrecurring Costs (NCs) on Sales of U.S. Items
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-04
... expenditures for machine tools, capital equipment, or facilities for which contractor rental payments are made.... Major defense equipment. Any item of significant military equipment on the United States Munitions List... the major defense equipment dollar threshold for research, development, test, and evaluation shall be...
van Delft, E A K; Schepers, T; Bonjer, H J; Kerkhoffs, G M M J; Goslings, J C; Schep, N W L
2018-04-01
Safety in the operating room is widely debated. Adverse events during surgery are potentially dangerous for the patient and staff. The incidence of adverse events during orthopedic trauma surgery is unknown. Therefore, we performed a study to quantify the incidence of these adverse events. Primary objective was to determine the incidence of adverse events related to technical equipment and logistics. The secondary objective was to evaluate the consequences of these adverse events. We completed a cross-sectional observational study to assess the incidence, consequences and preventability of adverse events related to technical equipment and logistics during orthopedic trauma surgery. During a 10 week period, all orthopedic trauma operations were evaluated by an observer. Six types of procedures were differentiated: osteosynthesis; arthroscopy; removal of hardware; joint replacement; bone grafting and other. Adverse events were divided in six categories: staff dependent factors; patient dependent factors; anaesthesia; imaging equipment; operation room equipment and instruments and implants. Adverse events were defined as any factor affecting the surgical procedure in a negative way. Hundred-fifty operative procedures were included. In 54% of the procedures, at least one adverse event occurred. In total, 147 adverse events occurred, with a range of 1-5 per procedure. Most adverse events occurred during joint replacement procedures. Thirty-seven percent of the incidents concerned defect, incorrect connected or absent instruments. In 36% of the procedures adverse events resulted in a prolonged operation time with a median prolongation of 10.0 min. In more than half of orthopedic trauma surgical procedures adverse events related to technical equipment and logistics occurred, most of them could easily be prevented. These adverse events could endanger the safety of the patient and staff and should therefore be reduced. 4.
Real World Crash Evaluation of Vehicle Stability Control (VSC) Technology
Bahouth, G.
2005-01-01
This study quantifies the effect of Vehicle Stability Control (VSC) in reducing crash involvement rates for a subset of vehicles in the US fleet. Crash rates for a variety of impact types before and after VSC technology was implemented are compared. Police-reported crashes from six available US state files from 1998–2002 were analyzed including 13,987 crash-involved study vehicles not equipped with the technology and 5,671 crashes of vehicles equipped with VSC as a standard feature. Overall, an 11.2% (95% CI: 2.4%, 21.1%) reduction in multi-vehicle frontal crash involvement was identified for VSC-equipped vehicles. A 52.6% (95% CI: 42.5%, 62.7%) reduction in single-vehicle crash rates was found. PMID:16179137
Real world crash evaluation of vehicle stability control (VSC) technology.
Bahouth, G
2005-01-01
This study quantifies the effect of Vehicle Stability Control (VSC) in reducing crash involvement rates for a subset of vehicles in the US fleet. Crash rates for a variety of impact types before and after VSC technology was implemented are compared. Police-reported crashes from six available US state files from 1998-2002 were analyzed including 13,987 crash-involved study vehicles not equipped with the technology and 5,671 crashes of vehicles equipped with VSC as a standard feature. Overall, an 11.2% (95% CI: 2.4%, 21.1%) reduction in multi-vehicle frontal crash involvement was identified for VSC-equipped vehicles. A 52.6% (95% CI: 42.5%, 62.7%) reduction in single-vehicle crash rates was found.
Electric and hybrid vehicles environmental control subsystem study
NASA Technical Reports Server (NTRS)
1981-01-01
An environmental control subsystem (ECS) in the passenger compartment of electric and hybrid vehicles is studied. Various methods of obtaining the desired temperature control for the battery pack is also studied. The functional requirements of ECS equipment is defined. Following categorization by methodology, technology availability and risk, all viable ECS concepts are evaluated. Each is assessed independently for benefits versus risk, as well as for its feasibility to short, intermediate and long term product development. Selection of the preferred concept is made against these requirements, as well as the study's major goal of providing safe, highly efficient and thermally confortable ECS equipment.
Operational flight evaluation of the two-segment approach for use in airline service
NASA Technical Reports Server (NTRS)
Schwind, G. K.; Morrison, J. A.; Nylen, W. E.; Anderson, E. B.
1975-01-01
United Airlines has developed and evaluated a two-segment noise abatement approach procedure for use on Boeing 727 aircraft in air carrier service. In a flight simulator, the two-segment approach was studied in detail and a profile and procedures were developed. Equipment adaptable to contemporary avionics and navigation systems was designed and manufactured by Collins Radio Company and was installed and evaluated in B-727-200 aircraft. The equipment, profile, and procedures were evaluated out of revenue service by pilots representing government agencies, airlines, airframe manufacturers, and professional pilot associations. A system was then placed into scheduled airline service for six months during which 555 two-segment approaches were flown at three airports by 55 airline pilots. The system was determined to be safe, easy to fly, and compatible with the airline operational environment.
Evaluation of advanced light scattering technology for microgravity experiments
NASA Technical Reports Server (NTRS)
Fredericks, W. J.; Rosenblum, W. M.
1990-01-01
The capabilities of modern light scattering equipment and the uses it might have in studying processes in microgravity are evaluated. Emphasis is on the resolution of polydisperse systems. This choice was made since a major use of light scattering was expected to be the study of crystal growth of macromolecules in low gravity environments. An evaluation of a modern photon correlation spectrometer and a Mie spectrometer is presented.
Mao, Xin; Yang, Yue
2017-02-01
The study aims to explore the challenges and the gaps faced by Chinese Drug Control Institutes in achieving the standards of World Health Organization (WHO) Medicine Prequalification. The study was undertaken with 6 Provincial Drug Control Institutes in China from November 2012 to November 2013. The study assessed key elements required to comply with WHO Good Practices for Pharmaceutical Quality Control Laboratories (GPPQCL). For GPPQCL, the study found gaps in quality management system, control of documentation, data-processing equipment, premises and equipment, contracts, reagents (water), reference substances and reference materials, calibration, verification of performance and qualification of equipment, instruments and other devices, analytical worksheet, evaluation of test results, personnel, and validation of analytical procedures. The study indicates that gaps are attributed to differences between the standards of Chinese Accreditation Standards and WHO-GPPQCL. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-01-03
The study, conducted by NEFT, was funded by the U.S. Trade and Development Agency. The report shows the results of a feasibility study conducted for the rehabilitation of oil wells in Baruskov and Tarasov fields. The objectives of the study include a plan for improving well and waterflood performance, and to determine materials and equipment needed. The report also covers capital and operating costs, as well as an evaluation of project economics based on Russian law. This is Volume 2 of the study containing Production Histories-Western Equipment. It is divided into the following sections: (1) Job Descriptions; (2) Barsukov Histories/Logs;more » (3) Tarasov Histories/Logs; (4) Taxes Paid by PNG; (5) Vendors Literature; (6) Rigs; (7) Liners; (8) Directional Drilling; (9) Mechanical Perforating; (10) Camps; (11) Pumps; (12) Fishing; (13) Downhole Oil/Water Separator; (14) Plastic.« less
ERIC Educational Resources Information Center
HOLMES, DAVID S.; AND OTHERS
THREE STUDIES OF PRESCHOOL CHILDREN ARE INCLUDED IN THIS EVALUATION REPORT. (1) "'NEURAL CONDUCTIVITY' AND ACHIEVEMENT IN CULTURALLY DEPRIVED STUDENTS." NEURAL CONDUCTIVITY WAS INFERRED FROM A CORRELATION BETWEEN PUPILLARY RESPONSE AND CHILDREN'S PRESCHOOL PERFORMANCE. COMPLICATIONS IN ACQUIRING AND USING THE NECESSARY EQUIPMENT RESULTED…
The main objective of this study is to evaluate the performance of candidate sampling methods for potential use as a Federal Reference Method (FRM) capable of providing an estimate of coarse particle (PMc: particulate matter with an aerodynamic diameter between 2.5 um and 10 um...
Turbidity monitoring equipment and methodology evaluation at MDOT construction sites.
DOT National Transportation Integrated Search
2014-12-01
State Study 261 is a continuation of State study 225, "Turbidity Monitoring at Select : MDOT Construction Sites", which was successful in establishing baseline stream data : at several active construction sites. State Study 261 focused on the equipme...
Floor vibration evaluations for medical facilities
NASA Astrophysics Data System (ADS)
Himmel, Chad N.
2003-10-01
The structural floor design for new medical facilities is often selected early in the design phase and in renovation projects, the floor structure already exists. Because the floor structure can often have an influence on the location of vibration sensitive medical equipment and facilities, it is becoming necessary to identify the best locations for equipment and facilities early in the design process. Even though specific criteria for vibration-sensitive uses and equipment may not always be available early in the design phase, it should be possible to determine compatible floor structures for planned vibration-sensitive uses by comparing conceptual layouts with generic floor vibration criteria. Relatively simple evaluations of planned uses and generic criteria, combined with on-site vibration and noise measurements early in design phase, can significantly reduce future design problems and expense. Concepts of evaluation procedures and analyses will be presented in this paper. Generic floor vibration criteria and appropriate parameters to control resonant floor vibration and noise will be discussed for typical medical facilities and medical research facilities. Physical, economic, and logistical limitations that affect implementation will be discussed through case studies.
Exploration of COTS Ultrasonic NDE Methods for ISS MMOD Impact Analysis
NASA Technical Reports Server (NTRS)
Violette, Daniel P.; Koshti, Ajay; Stanley, David
2012-01-01
The high orbital speed of the International Space Station (ISS) has created a concern about Micro-Meteorite and Orbital Debris (MMOD). The possibility exists that such an impact could cause significant damage to the ISS pressure wall, and possibly lead to a pressure leak. This paper explores the potential of using commercial off-the-shelf (COTS) Ultrasonic Non-Destructive Evaluation (NDE) techniques in order to inspect and analyze MMOD impact damage if such an event would happen to occur. Different types of intra vehicular activity (IVA) Ultrasonic NDE equipment were evaluated, including the Olympus Omniscan MX and the General Electric Phasor XS. The equipment was tested by inspecting various aluminum standards and impact damage test plates in order to determine technological limitations of the equipment as well as the ease of use and availability of features. This study allowed for the design of scanning procedures in order to evaluate the extent of damage caused by an MMOD impact. Lastly, comparisons were drawn between the different pieces of COTS software and a recommendation is made based on each device s capability.
Risør, Bettina Wulff; Casper, Sven Dalgas; Andersen, Lars Louis; Sørensen, Jan
2017-04-01
This study evaluated an intervention for patient-handling equipment aimed to improve nursing staffs' use of patient handling equipment and improve their general health, reduce musculoskeletal problems, aggressive episodes, days of absence and work-related accidents. As a controlled before-after study, questionnaire data were collected at baseline and 12-month follow-up among nursing staff at intervention and control wards at two hospitals. At 12-month follow-up, the intervention group had more positive attitudes towards patient-handling equipment and increased use of specific patient-handling equipment. In addition, a lower proportion of nursing staff in the intervention group had experienced physically aggressive episodes. No significant change was observed in general health status, musculoskeletal problems, days of absence or work-related accidents. The intervention resulted in more positive attitudes and behaviours for safe patient-handling and less physically aggressive episodes. However, this did not translate into improved health of the staff during the 12-month study period. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hybrid Damping System for an Electronic Equipment Mounting Shelf
NASA Technical Reports Server (NTRS)
Voracek, David; Kolkailah, Faysal A.; Cavalli, J. R.; Elghandour, Eltahry
1997-01-01
The objective of this study was to design and construct a vibration control system for an electronic equipment shelf to be evaluated in the NASA Dryden FTF-II. The vibration control system was a hybrid system which included passive and active damping techniques. Passive damping was fabricated into the equipment shelf using ScothDamp(trademark) damping film and aluminum constraining layers. Active damping was achieved using a two channel active control circuit employing QuickPack(trademark) sensors and actuators. Preliminary Chirp test results indicated passive damping smoothed the frequency response while active damping reduced amplitudes of the frequency response for most frequencies below 500Hz.
Hybrid Damping System for an Electronic Equipment Mounting Shelf
NASA Technical Reports Server (NTRS)
Voracek, David; Kolkailah, Faysal A.; Cavalli, J. R.; Elghandour, Eltahry
1997-01-01
The objective of this study was to design and construct a vibration control system for an electronic equipment shelf to be evaluated in the NASA Dryden FTF-11. The vibration control system was a hybrid system which included passive and active damping techniques. Passive damping was fabricated into the equipment shelf using ScothDamp(trademark) damping film and aluminum constraining layers. Active damping was achieved using a two channel active control circuit employing QuickPack(trademark) sensors and actuators. Preliminary Chirp test results indicated passive damping smoothed the frequency response while active damping reduced amplitudes of the frequency response for most frequencies below 500Hz.
1980-09-01
Needs 75 DEVELOPMENT OF DREDGING COST ESTIMATES 76 IMPLEMENTATION OF SELECTED PLAN 77 EVALUATION OF SELECTED PLAN 78 NATIONAL ECONOMIC DEVELOPMENT EFFECTS ...78 ENVIRONMENTAL QUALITY EFFECTS 78 TABLE OF CONTENTS (CONT) ITEM PAGE RECOMM*ENDATIONS 79 THE DREDGE WILLIAM A. THOMPSON 79 MECHANICAL DREDGING...and cost effective for implementing a recommended channel maintenance plan. 3. Suggesting which types of equipment and techniques are best suited for
1980-09-01
evaluated. The objectis e of this study was to isolate classroom and field performance differences as a function of the training equipnment used and to...THIS PAtICmmUn bat. Saelrwo Item 20 (Continued): ausperviser followup questionnaires were administered in the field to provide additional feedback about...competent maintenance technicians to the field . As a train- ing device, actual equipment does not readily permit the controlled presentation of
Fernandes, Natália Martinez; Pelissari, Isadora Gonçalves; Cogo, Licia Assunção; Santos Filha, Valdete Alves Valentins dos
2016-01-01
Introduction The manipulation of antineoplastic drugs presents high risk for accidents and occupational diseases. Objective To evaluate the auditory and vestibular systems of workers who are exposed to chemotherapeutic treatment in the University Hospital of Universidade Federal de Santa Maria, Brazil, and to identify the use of individual protection equipment, related to the obtained results. Methods This study is a cross-sectional study using a quantitative method. We evaluate 33 male and female workers, ranging from 21–60 years old, of the nursing and pharmacy sectors. The workers underwent conventional Audiologic Assessment; Transient Evoked Otoacoustic Emissions; and Computerized Vectoelectronystagmography. Results The majority of the sample was female (90.9%). Individual protection equipment was used by 90.9% of the workers. Complaints of dizziness were reported by 56.25% of nursing workers and 52.94% of pharmacy workers. Audiological and vestibular assessment results were within normal limits, 96.97% and 74.20%, respectively. However, audiometric configuration of notch type was identified in 75.75% of all workers. Audiometric notches (76%) and altered caloric test (100%) were often associated with decreased use of coal masks. Conclusion Among the workers evaluated, the vestibulocochlear system was within the normal limits. The presence of notch configuration indicates the need to use individual protection equipment. PMID:27746836
Photosynthetic and respiratory activity in germfree higher plant species
NASA Technical Reports Server (NTRS)
1976-01-01
Equipment developed for the study of gas exchange in germfree plants is described. The equipment includes a gas exchange chamber to house the plant under study, a gas feed assembly to introduce and remove gas from the chamber, and a clinostat to rotate the apparatus. Fluorescent and incandescent lights are used to illuminate the chamber and a sealed plastic barrier is used to isolate the potting soil from the chamber atmosphere. The gas outflow from the chamber can be diverted to an infrared CO2 analyzer. The performance of the system was evaluated.
Oxygen equipment and rapid decompression studies.
DOT National Transportation Integrated Search
1979-03-01
This is a collection of reports of evaluations of the protective capability of various oxygen systems at high altitude and during rapid decompression. Results of these studies were presented at scientific meetings and/or published in preprints or pro...
Shuttle orbiter S-band payload communications equipment design evaluation
NASA Technical Reports Server (NTRS)
Springett, J. C.; Maronde, R. G.
1979-01-01
The analysis of the design, and the performance assessment of the Orbiter S-band communication equipment are reported. The equipment considered include: network transponder, network signal processor, FM transmitter, FM signal processor, payload interrogator, and payload signal processor.
Gresits, Iván; Necz, Péter Pál; Jánossy, Gábor; Thuróczy, György
2015-09-01
Measurements of extremely low frequency (ELF) magnetic fields were conducted in the environment of commercial laboratory equipment in order to evaluate the possible co-exposure during the experimental processes on cell cultures. Three types of device were evaluated: a cell culture CO2 incubator, a thermostatic water bath and a laboratory shaker table. These devices usually have electric motors, heating wires and electronic control systems, therefore may expose the cell cultures to undesirable ELF stray magnetic fields. Spatial distributions of magnetic field time domain signal waveform and frequency spectral analysis (FFT) were processed. Long- and short-term variation of stray magnetic field was also evaluated under normal use of investigated laboratory devices. The results show that the equipment under test may add a considerable ELF magnetic field to the ambient environmental magnetic field or to the intentional exposure to ELF, RF or other physical/chemical agents. The maximum stray magnetic fields were higher than 3 µT, 20 µT and 75 µT in the CO2 incubator, in water bath and on the laboratory shaker table, respectively, with high variation of spatial distribution and time domain. Our investigation emphasizes possible confounding factors conducting cell culture studies related to low-level ELF-EMF exposure due to the existing stray magnetic fields in the ambient environment of laboratory equipment.
Study directed at development of an implantable biotelemetry ion detector
NASA Technical Reports Server (NTRS)
Hanley, L. D.; Kress, D.
1971-01-01
A literature search was conducted to currently update known information in the field of ion-selective electrodes. The review attempts to identify present trends in cation and anions selective electrodes pertinent to the area of bioimplantable units. An electronic circuit was designed to provide the high impedance interface between the ion-selective sensors and signal-processing equipment. The resulting design emphasized the need for low power and miniaturization. Many of the circuits were constructed and used to evaluate the ion-selective electrodes. A cuvette capable of holding the ion-selective and the reference electrodes was designed and constructed. This equipment was used to evaluate commercially available ion-selective electrodes and the electrodes designed and constructed in the study. The results of the electrode tests are included.
DOT National Transportation Integrated Search
2012-03-01
This research study aims at evaluating the performance of base and subgrade soil in flexible pavements under repeated loading test conditions. For this purpose, an indoor cyclic plate load testing equipment was developed and used to conduct a series ...
DOT National Transportation Integrated Search
2008-06-01
The objective of this research study was to perform a thorough evaluation of the feasibility and cost implications for initial system installation and ongoing program and maintenance costs for a land port of entry truck emissions program utilizing he...
Gross decontamination experiment report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, R.; Kinney, K.; Dettorre, J.
1983-07-01
A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established formore » the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment.« less
Application of Oversampling to obtain the MTF of Digital Radiology Equipment.
NASA Astrophysics Data System (ADS)
Narváez, M.; Graffigna, J. P.; Gómez, M. E.; Romo, R.
2016-04-01
Within the objectives of theproject Medical Image Processing for QualityAssessment ofX Ray Imaging, the present research work is aimed at developinga phantomX ray image and itsassociated processing algorithms in order to evaluatethe image quality rendered by digital X ray equipment. These tools are used to measure various image parameters, among which spatial resolution shows afundamental property that can be characterized by the Modulation Transfer Function (MTF)of an imaging system [1]. After performing a thorough literature surveyon imaging quality control in digital X film in Argentine and international publications, it was decided to adopt for this work the Norm IEC 62220 1:2003 that recommends using an image edge as a testingmethod. In order to obtain the characterizing MTF, a protocol was designedfor unifying the conditions under which the images are acquired for later evaluation. The protocol implied acquiring a radiography image by means of a specific referential technique, i.e. referred either to voltage, current, time, distance focus plate (/film?) distance, or other referential parameter, and to interpret the image through a system of computed radiology or direct digital radiology. The contribution of the work stems from the fact that, even though the traditional way of evaluating an X film image quality has relied mostly on subjective methods, this work presents an objective evaluative toolfor the images obtained with a givenequipment, followed by a contrastive analysis with the renderings from other X filmimaging sets.Once the images were obtained, specific calculations were carried out. Though there exist some methods based on the subjective evaluation of the quality of image, this work offers an objective evaluation of the equipment under study. Finally, we present the results obtained on different equipment.
Building Assessment Survey and Evaluation Study Summarized Data - HVAC Characteristics
In the Building Assessment Survey and Evaluation (BASE) Study Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations, and operation and maintenance issues was acquired by examining the building plans, conducting a building walk-through, and speaking with the building owner, manager, and/or operator.
14 CFR 142.55 - Training center evaluator requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... corrective action; and (4) If evaluating in qualified and approved flight training equipment must satisfactorily pass a written test and annual proficiency check in a flight simulator or aircraft in which the... (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES TRAINING CENTERS Personnel and Flight Training Equipment...
14 CFR 142.55 - Training center evaluator requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... corrective action; and (4) If evaluating in qualified and approved flight training equipment must satisfactorily pass a written test and annual proficiency check in a flight simulator or aircraft in which the... (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES TRAINING CENTERS Personnel and Flight Training Equipment...
14 CFR 142.55 - Training center evaluator requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... corrective action; and (4) If evaluating in qualified and approved flight training equipment must satisfactorily pass a written test and annual proficiency check in a flight simulator or aircraft in which the... (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES TRAINING CENTERS Personnel and Flight Training Equipment...
14 CFR 142.55 - Training center evaluator requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... corrective action; and (4) If evaluating in qualified and approved flight training equipment must satisfactorily pass a written test and annual proficiency check in a flight simulator or aircraft in which the... (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES TRAINING CENTERS Personnel and Flight Training Equipment...
14 CFR 142.55 - Training center evaluator requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... corrective action; and (4) If evaluating in qualified and approved flight training equipment must satisfactorily pass a written test and annual proficiency check in a flight simulator or aircraft in which the... (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES TRAINING CENTERS Personnel and Flight Training Equipment...
Electro-optics laboratory evaluation: Deutsch optical waveguide connectors
NASA Technical Reports Server (NTRS)
1980-01-01
A description of a test program evaluating the performance of an optical waveguide connector system is presented. Both quality and effectiveness of connections made in an optical fiber, performance of the equipment used and applicability of equipment and components to field conditions are reviewed.
33 CFR 148.400 - What does this subpart do?
Code of Federal Regulations, 2011 CFR
2011-07-01
... and other equipment; and (3) Studies done for the preparation of the environmental analysis required... evaluation and pre-construction testing” means studies performed at potential deepwater port locations, including: (1) Preliminary studies to determine the feasibility of a site; (2) Detailed studies of the...
33 CFR 148.400 - What does this subpart do?
Code of Federal Regulations, 2010 CFR
2010-07-01
... and other equipment; and (3) Studies done for the preparation of the environmental analysis required... evaluation and pre-construction testing” means studies performed at potential deepwater port locations, including: (1) Preliminary studies to determine the feasibility of a site; (2) Detailed studies of the...
Oguchi, Masahiro; Murakami, Shinsuke; Sakanakura, Hirofumi; Kida, Akiko; Kameya, Takashi
2011-01-01
End-of-life electrical and electronic equipment (EEE) has recently received attention as a secondary source of metals. This study examined characteristics of end-of-life EEE as secondary metal resources to consider efficient collection and metal recovery systems according to the specific metals and types of EEE. We constructed an analogy between natural resource development and metal recovery from end-of-life EEE and found that metal content and total annual amount of metal contained in each type of end-of-life EEE should be considered in secondary resource development, as well as the collectability of the end-of-life products. We then categorized 21 EEE types into five groups and discussed their potential as secondary metal resources. Refrigerators, washing machines, air conditioners, and CRT TVs were evaluated as the most important sources of common metals, and personal computers, mobile phones, and video games were evaluated as the most important sources of precious metals. Several types of small digital equipment were also identified as important sources of precious metals; however, mid-size information and communication technology (ICT) equipment (e.g., printers and fax machines) and audio/video equipment were shown to be more important as a source of a variety of less common metals. The physical collectability of each type of EEE was roughly characterized by unit size and number of end-of-life products generated annually. Current collection systems in Japan were examined and potentially appropriate collection methods were suggested for equipment types that currently have no specific collection systems in Japan, particularly for video games, notebook computers, and mid-size ICT and audio/video equipment. Copyright © 2011 Elsevier Ltd. All rights reserved.
Implementation research to improve quality of maternal and newborn health care, Malawi
Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela
2017-01-01
Abstract Objective To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. Methods We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities’ essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. Findings We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants’ adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Conclusion Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care. PMID:28670014
Connected Equipment Maturity Model Version 1.0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butzbaugh, Joshua B.; Mayhorn, Ebony T.; Sullivan, Greg
2017-05-01
The Connected Equipment Maturity Model (CEMM) evaluates the high-level functionality and characteristics that enable equipment to provide the four categories of energy-related services through communication with other entities (e.g., equipment, third parties, utilities, and users). The CEMM will help the U.S. Department of Energy, industry, energy efficiency organizations, and research institutions benchmark the current state of connected equipment and identify capabilities that may be attained to reach a more advanced, future state.
Occupational exposure of personnel operating military radio equipment: measurements and simulation.
Paljanos, Annamaria; Miclaus, Simona; Munteanu, Calin
2015-09-01
Technical literature provides numerous studies concerning radiofrequency exposure measurements for various radio communication devices, but there are few studies related to exposure of personnel operating military radio equipment. In order to evaluate exposure and identify cases when safety requirements are not entirely met, both measurements and simulations are needed for accurate results. Moreover, given the technical characteristics of the radio devices used in the military, personnel mainly operate in the near-field region so both measurements and simulation becomes more complex. Measurements were made in situ using a broadband personal exposimeter equipped with two isotropic probes for both electric and magnetic components of the field. The experiment was designed for three different operating frequencies of the same radio equipment, while simulations were made in FEKO software using hybrid numerical methods to solve complex electromagnetic field problems. The paper aims to discuss the comparative results of the measurements and simulation, as well as comparing them to reference levels specified in military or civilian radiofrequency exposure standards.
The potential of telehealth for 'business as usual' in outpatient clinics.
Day, Karen; Kerr, Patricia
2012-04-01
A six-month pilot study was conducted to ascertain the value of using high-definition videoconferencing equipment in an outpatients' setting. The videoconferencing equipment, which included digital biometric equipment, was installed in the outpatient clinics of a remote health service in New Zealand. Use of the equipment was evaluated using action research techniques. Clinicians were interviewed about their assessment of the equipment's usefulness. Patients and their carers completed questionnaires about their clinic experience. During the pilot trial, 109 patients were seen in 25 clinics of six different specialities. Questionnaire results showed that patients and their companions had a good user experience, similar to a face-to-face appointment. Clinicians found that the large screen, sense of proximity, video clarity and definition, and lack of sound/picture lag worked well for certain types of outpatients' clinics, e.g. methadone maintenance clinics. The need for process changes made it difficult to turn telehealth into business as usual in an environment built for face-to-face appointments. We conclude that videoconference equipment has potential to become integral to outpatients' clinics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-11-03
Holston Army Ammunition Plant (HSAAP) in Holston, Tennessee, manufactures explosives from raw materials. The facility comprises two separate areas designated Area `A11 and Area 11B`. Each area is served by a steam plant which produces steam for production processes, equipment operation, space heating, domestic water heating, steam tracing, and product storage heating requirements. The purpose of this study is to identify and evaluate the technical and economic feasibility of alternative methods of meeting the steam requirements of the Area 11A11 industrial complex. The following items were specifically requested to be evaluated. Evaluate the use of two new gas-fired packaged boilersmore » sized to meet the requirements of the industrial complex. The new boilers would be installed adjacent to the existing steam plant and would utilize the existing smokestacks and steam distribution system. Evaluate using the existing steam distribution system rather than locating multiple boilers at various sites. Existing steam driven chillers will be replaced with electric driven equipment. Evaluate this impact on the steam system requirements. Field survey and test two existing gas-fired packaged boilers located at the Volunteer Army Ammunition Plant in Chattanooga, Tennessee. The two boilers were last used about 1980 and are presently laid away. The boilers are approximately the same capacity and operating characteristics as the ones at HSAAP. Relocation of the existing boilers and ancillary equipment (feedwater pumps, generators, fans, etc.) would be required as well as repairs or modifications necessary to meet current operating conditions and standards.« less
Augmentor transient capability of an F100 engine equipped with a digital electronic engine control
NASA Technical Reports Server (NTRS)
Burcham, F. W., Jr.; Pai, G. D.
1984-01-01
An F100 augmented turbofan engine equipped with digital electronic engine control (DEEC) system was evaluated. The engine was equipped with a specially modified augmentor to provide improved steady state and transient augmentor capability. The combination of the DEEC and the modified augmentor was evaluated in sea level and altitude facility tests and then in four different flight phases in an F-15 aircraft. The augmentor configuration, logic, and test results are presented.
Survey of injury sources for a trampoline with equipment hazards designed out
Eager, David; Scarrott, Carl; Nixon, Jim; Alexander, Keith
2012-01-01
Aim In Australia, trampolines contribute approximately one-quarter of all childhood play-equipment injuries. The purpose of this study was to gather and evaluate injury data from a nontraditional, ‘soft-edged’, consumer trampoline in which the equipment injury sources have been designed out. Methods A survey was undertaken in Queensland and New South Wales. The manufacturer of the nontraditional trampoline provided the University of Technology, Sydney, with their Australian customer database. Injury data were gathered in a pilot study by phone interview, then in a full study through an email survey. Results from 3817 respondents were compared with earlier Australian and US data from traditional trampolines gathered from emergency departments. Results A significantly lower proportion of the injuries caused by falling off or striking the equipment was found for this new design when compared with traditional trampolines both in Australia and in the USA. The age of children being injured on trampolines in Australia was found to be markedly lower than in North America. Conclusions This research indicates that with appropriate design the more severe injuries on traditional trampolines can be significantly reduced. PMID:22404557
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oguchi, Masahiro, E-mail: oguchi.masahiro@nies.go.jp; Murakami, Shinsuke; Sakanakura, Hirofumi
2011-09-15
Highlights: > End-of-life electrical and electronic equipment (EEE) as secondary metal resources. > The content and the total amount of metals in specific equipment are both important. > We categorized 21 EEE types from contents and total amounts of various metals. > Important equipment types as secondary resources were listed for each metal kind. > Collectability and possible collection systems of various EEE types were discussed. - Abstract: End-of-life electrical and electronic equipment (EEE) has recently received attention as a secondary source of metals. This study examined characteristics of end-of-life EEE as secondary metal resources to consider efficient collection andmore » metal recovery systems according to the specific metals and types of EEE. We constructed an analogy between natural resource development and metal recovery from end-of-life EEE and found that metal content and total annual amount of metal contained in each type of end-of-life EEE should be considered in secondary resource development, as well as the collectability of the end-of-life products. We then categorized 21 EEE types into five groups and discussed their potential as secondary metal resources. Refrigerators, washing machines, air conditioners, and CRT TVs were evaluated as the most important sources of common metals, and personal computers, mobile phones, and video games were evaluated as the most important sources of precious metals. Several types of small digital equipment were also identified as important sources of precious metals; however, mid-size information and communication technology (ICT) equipment (e.g., printers and fax machines) and audio/video equipment were shown to be more important as a source of a variety of less common metals. The physical collectability of each type of EEE was roughly characterized by unit size and number of end-of-life products generated annually. Current collection systems in Japan were examined and potentially appropriate collection methods were suggested for equipment types that currently have no specific collection systems in Japan, particularly for video games, notebook computers, and mid-size ICT and audio/video equipment.« less
Evaluation of critical indicators in the process of acquiring supplies and services LAC-UFPE
NASA Astrophysics Data System (ADS)
Caetano, V. F.; Ferreira, C. V.; dos Santos, M. J.; Honorato, F. A.
2015-01-01
In laboratories linked to public universities and accredited by the NBR ISO/IEC 17025, to meet efficiently item 4.6 (procurement of supplies and services) is a challenge that can be accomplished by programming based on historical purchases and services. In this study, we evaluated the critical procurement items to meet the quality management system of the LAC-UFPE: reagents, certified reference material, of equipment parts, maintenance and calibration of equipment and instruments. It was found that the most critical item is the certified reference material, the purchase or repair of which must be expedited within 125 days prior to the receipt to occur within the desired period.
Jeong, Eunbi; Oh, Cheol; Lee, Seolyoung
2017-07-01
Automated driving systems (ADSs) are expected to prevent traffic accidents caused by driver carelessness on freeways. There is no doubt regarding this safety benefit if all vehicles in the transportation system were equipped with ADSs; however, it is implausible to expect that ADSs will reach 100% market penetration rate (MPR) in the near future. Therefore, the following question arises: 'Can ADSs, which consider only situations in the vicinity of an equipped vehicle, really contribute to a significant reduction in traffic accidents?' To address this issue, the interactions between equipped and unequipped vehicles must be investigated, which is the purpose of this study. This study evaluated traffic safety at different MPRs based on a proposed index to represent the overall rear-end crash risk of the traffic stream. Two approaches were evaluated for adjusting longitudinal vehicle maneuvers: vehicle safety-based maneuvering (VSM), which considers the crash risk of an equipped vehicle and its neighboring vehicles, and traffic safety-based maneuvering (TSM), which considers the overall crash risk in the traffic stream. TSM assumes that traffic operational agencies are able to monitor all the vehicles and to intervene in vehicle maneuvering. An optimization process, which attempts to obtain vehicle maneuvering control parameters to minimize the overall crash risk, is integrated into the proposed evaluation framework. The main purpose of employing the optimization process for vehicle maneuvering in this study is to identify opportunities to improve traffic safety through effective traffic management rather than developing a vehicle control algorithm that can be implemented in practice. The microscopic traffic simulator VISSIM was used to simulate the freeway traffic stream and to conduct systematic evaluations based on the proposed methodology. Both TSM and VSM achieved significant reductions in the potential for rear-end crashes. However, TSM obtained much greater reductions when the MPR was greater than 50%. This study should inspire transportation researchers and engineers to develop effective traffic operations strategies for automated driving environments. Copyright © 2017. Published by Elsevier Ltd.
Hirayama, Denise; Saron, Clodoaldo
2015-06-01
Polymeric materials constitute a considerable fraction of waste computer equipment and polymers acrylonitrile-butadiene-styrene and high-impact polystyrene are the main thermoplastic polymeric components found in waste computer equipment. Identification, separation and characterisation of additives present in acrylonitrile-butadiene-styrene and high-impact polystyrene are fundamental procedures to mechanical recycling of these polymers. The aim of this study was to evaluate the methods for identification of acrylonitrile-butadiene-styrene and high-impact polystyrene from waste computer equipment in Brazil, as well as their potential for mechanical recycling. The imprecise utilisation of symbols for identification of the polymers and the presence of additives containing toxic elements in determinate computer devices are some of the difficulties found for recycling of acrylonitrile-butadiene-styrene and high-impact polystyrene from waste computer equipment. However, the considerable performance of mechanical properties of the recycled acrylonitrile-butadiene-styrene and high-impact polystyrene when compared with the virgin materials confirms the potential for mechanical recycling of these polymers. © The Author(s) 2015.
Evaluation of the Redesign of an Undergraduate Cell Biology Course
McEwen, Laura April; Harris, dik; Schmid, Richard F.; Vogel, Jackie; Western, Tamara
2009-01-01
This article offers a case study of the evaluation of a redesigned and redeveloped laboratory-based cell biology course. The course was a compulsory element of the biology program, but the laboratory had become outdated and was inadequately equipped. With the support of a faculty-based teaching improvement project, the teaching team redesigned the course and re-equipped the laboratory, using a more learner-centered, constructivist approach. The focus of the article is on the project-supported evaluation of the redesign rather than the redesign per se. The evaluation involved aspects well beyond standard course assessments, including the gathering of self-reported data from the students concerning both the laboratory component and the technical skills associated with the course. The comparison of pre- and postdata gave valuable information to the teaching team on course design issues and skill acquisition. It is argued that the evaluation process was an effective use of the scarce resources of the teaching improvement project. PMID:19255138
2013-01-01
Background Chronic low back pain is an expensive and difficult condition to treat. One of the interventions widely used by physiotherapists in the treatment of chronic non-specific low back pain is exercise therapy based upon the Pilates principles. Pilates exercises can be performed with or without specific equipment. These two types of Pilates exercises have never been compared on a high-quality randomised controlled trial. Methods/design This randomised controlled trial with a blinded assessor will evaluate eighty six patients of both genders with chronic low back pain, aged between 18 and 60 years, from one Brazilian private physiotherapy clinic. The patients will be randomly allocated into two groups: Mat Group will perform the exercises on the ground while the Equipment-based Group will perform the Pilates method exercises on the following equipment: Cadillac, Reformer, Ladder Barrel, and Step Chair. The general and specific disability of the patient, kinesiophobia, pain intensity and global perceived effect will be evaluated by a blinded assessor before randomisation and at six weeks and six months after randomisation. In addition, the expectation of the participants and their confidence with the treatment will be evaluated before randomisation and after the first treatment session, respectively. Discussion This will be the first study aiming to compare the effectiveness of Mat and Equipment-based Pilates exercises in patients with chronic non-specific low back pain. The results may help health-care professionals in clinical decision-making and could potentially reduce the treatment costs of this condition. Trial registration Brazilian Registry of Clinical Trials RBR-7tyg5j PMID:23298183
Performance Indexing: Assessing the Nonmonetized Returns on Investment in Military Equipment
2016-05-17
investment’s value (return) because it cannot be objectively quanti - fied. To support resource allocation decisions, our mission was to provide accurate and...timely analyses with readily available information. In fiscal year 2014, the Marine Corps evaluated its strategic equipment investment initiatives...battle outcomes (Department of the Air Force, 1996). Elaborate opera- tional testing and evaluation events are created to evaluate these measures
30 CFR 36.21 - Engine for equipment considered for certification.
Code of Federal Regulations, 2013 CFR
2013-07-01
... considered for certification. Only equipment powered by a compression-ignition (diesel) engine and burning... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Engine for equipment considered for... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS APPROVAL REQUIREMENTS FOR PERMISSIBLE MOBILE DIESEL...
30 CFR 36.21 - Engine for equipment considered for certification.
Code of Federal Regulations, 2011 CFR
2011-07-01
... considered for certification. Only equipment powered by a compression-ignition (diesel) engine and burning... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Engine for equipment considered for... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS APPROVAL REQUIREMENTS FOR PERMISSIBLE MOBILE DIESEL...
30 CFR 36.21 - Engine for equipment considered for certification.
Code of Federal Regulations, 2012 CFR
2012-07-01
... considered for certification. Only equipment powered by a compression-ignition (diesel) engine and burning... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Engine for equipment considered for... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS APPROVAL REQUIREMENTS FOR PERMISSIBLE MOBILE DIESEL...
30 CFR 36.21 - Engine for equipment considered for certification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... considered for certification. Only equipment powered by a compression-ignition (diesel) engine and burning... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Engine for equipment considered for... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS APPROVAL REQUIREMENTS FOR PERMISSIBLE MOBILE DIESEL...
30 CFR 36.21 - Engine for equipment considered for certification.
Code of Federal Regulations, 2010 CFR
2010-07-01
... considered for certification. Only equipment powered by a compression-ignition (diesel) engine and burning... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Engine for equipment considered for... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS APPROVAL REQUIREMENTS FOR PERMISSIBLE MOBILE DIESEL...
Evaluation of the effectiveness of salt neutralizers for washing snow and ice equipment.
DOT National Transportation Integrated Search
2014-01-01
In winter maintenance, the chloride-based deicers used to keep roadways clear of : snow and ice are highly corrosive to vehicles and equipment. Corrosion of snow and ice equipment : is a major issue causing increased maintenance and repair costs, red...
NASA Technical Reports Server (NTRS)
1979-01-01
Topics covered include growth options evaluation, mass properties, attitude control and structural dynamics, contamination evaluation, berthing concepts, orbit reboost options and growth kit concepts. Systems support elements and space support equipment are reviewed with emphasis on power module operations and technology planning.
Flabouris, Arthas; Nocera, Antony; Garner, Alan
2004-01-01
Multiple casualty incidents (MCI) are infrequent events for medical systems. This renders audit and quality improvement of the medical responses difficult. Quality tools and use of such tools for improvement is necessary to ensure that the design of medical systems facilitates the best possible response to MCI. To describe the utility of incident reporting as a quality monitoring and improvement tool during the deployment of medical teams for mass gatherings and multiple casualty incidents. Voluntary and confidential reporting of incidents was provided by members of the disaster medical response teams during the period of disaster medical team deployment for the 2000 Sydney Olympic Games. Qualitative evaluations were conducted of reported incidents. The main outcome measures included the nature of incident and associated contributing factors, minimization factors, harm potential, and comparison with the post-deployment, cold debriefings. A total of 53 incidents were reported. Management-based decisions, poor or non-existent protocols, and equipment and communication-related issues were the principal contributing factors. Eighty nine percent of the incidents were considered preventable. A potential for harm to patients and/or team members was documented in 58% of reports, of which 76% were likely to cause at least significant harm. Of equipment incidents, personal protective equipment (33%), medical equipment (27%), provision of equipment (22%), and communication equipment (17%) predominated. Personal protective equipment (50%) was reported as the most frequent occupational health and safety incident followed by fatigue (25%). Pre-deployment planning was the most important factor for future incident impact minimization. Incident monitoring was efficacious as a quality tool in identifying incident contributing factors. Incident monitoring allowed for greater systems evaluation. Further evaluation of this quality tool within different disaster settings is required.
Guirro, Rinaldo Roberto de Jesus; Weis, Luciana Cezimbra
2009-08-01
The main objectives of this study were to characterize low-level laser therapy (LLLT) and the physical therapy clinical procedures for its use. There are few scientific studies that characterize the calibration of LLLT equipment. Forty lasers at 36 physical therapy clinics were selected. The equipment was characterized through data collected from the owner manuals, direct consultation with the manufacturers, and a questionnaire answered by the users. A digital potency analyzer was used to calibrate released mean potency. Qualitative data were presented throughout the descriptive statistics and quantitative data were analyzed by the Wilcoxon/Kruskal-Wallis and Fisher tests (significance, p < 0.05). The laser equipment was either AsGa (70.5%) or HeNe (23.5%), and 60% was analog and acquired over 5 years ago. The majority of the equipment was used 10-15 times per week and the most frequent density level used was 2 to 4 J/cm(2). Protective goggles were available in only 19.4% of the clinics evaluated. The association between the analyzed categories demonstrated that a lower mean potency was correlated both with equipment acquired over 5 years ago and analog technology. The determined mean potency was lower than the one claimed by the manufacturer (p < 0.05). In 30 cases, the analyzed equipment presented a potency between 3 microW and 5.6 mW; in three cases, the potency was >25 mW; and in seven cases, potency was nonexistent. The analyzed equipment was out-dated and periodical maintenance was not conducted, which was reflected in the low irradiated potency.
Cost analysis of equipment failure of a radiology department and possible choices about maintenance.
Grisi, Guido; Dalla Palma, Ludovico; Rimondini, Allesandra; Palmolungo, Chiara; Cuttin Zernich, Roberto; Pozzi Mucelli, Roberto
2002-01-01
Our aim was to evaluate the economic impact of equipment failures in a radiology department with a view to guiding maintenance policy decisions. We assessed the negative economic impact caused by the interruption of activity of a radiodiagnostics section due to equipment failure, taking into account: the effects occurring during the first day of equipment down-time (assuming that the equipment failure occurs in the middle of the shift) and the effects during the following days until the repair of the failure; the effects occurring in the short- and long-term. To exemplify the negative impact of inactivity due to equipment failure, we chose three radiology sections with different levels of technological and operational complexity (chest radiology, gastrointestinal radiology and remote-controlled diagnostics). For each, we evaluated the loss of contribution margin and the idle capacity costs (short- and long-term impact). The negative economic effects were: for thoracic radiology, 496,77 Euro in the first day, and 30,99 Euro from the second day onwards; for gastrointestinal radiology, 526,40 Euro for the first day, and 730,39 Euro from the second day onwards; for remote-controlled diagnostics, 786,25 Euro for the first day, and 927,67 Euro from the second days onwards. Our results indicate that the level of idle capacity costs (mainly equipment and staff) increases with the complexity of the equipment, whereas the contribution margin appears to fluctuate, because the charges are state-imposed and do not vary with the complexity of equipment. Moreover, our analysis shows that if the workload of a broken machine can easily be assigned to an additional shift using another machine, losses are considerably reduced from the second day onwards. Once the negative economic impact of equipment failures has been evaluated, the second step is to choose the best kind of maintenance. A sound calculation of the economic impact of equipment failures is very useful for guiding the head of department and the hospital manager in deciding whether to purchase maintenance services (or a long-term guarantee) from the equipment manufacturer, to set up an auxiliary centre for maintenance and repair, or to purchase a third-party maintenance contract.
A new era for Nuclear Medicine neuroimaging in Spain: Where do we start from in Spain?
Balsa, M A; Camacho, V; Garrastachu, P; García-Solís, D; Gómez-Río, M; Rubí, S; Setoain, X; Arbizu, J
To determine the status of neuroimaging studies of Nuclear Medicine in Spain during 2013 and first quarter of 2014, in order to define the activities of the neuroimaging group of the Spanish Society of Nuclear Medicine and Molecular Imaging (SEMNIM). A questionnaire of 14 questions was designed, divided into 3 parts: characteristics of the departments (equipment and professionals involved); type of scans and clinical indications; and evaluation methods. The questionnaire was sent to 166 Nuclear Medicine departments. A total of 54 departments distributed among all regions completed the questionnaire. Most departments performed between 300 and 800 neuroimaging examinations per year, representing more than 25 scans per month. The average pieces of equipment were three; half of the departments had a PET/CT scanner and SPECT/CT equipment. Scans performed more frequently were brain SPECT with 123 I-FP-CIT, followed by brain perfusion SPECT and PET with 18 F-FDG. The most frequent clinical indications were cognitive impairment followed by movement disorders. For evaluation of the images most sites used only visual assessment, and for the quantitative assessment the most used was quantification by region of interest. These results reflect the clinical activity of 2013 and first quarter of 2014. The main indications of the studies were cognitive impairment and movement disorders. Variability in the evaluation of the studies is among the challenges that will be faced in the coming years. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
7 CFR 3300.70 - Issuance of certificate.
Code of Federal Regulations, 2014 CFR
2014-01-01
... BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of New Equipment § 3300.70 Issuance of certificate. The ATP manager will evaluate the documents received and, for equipment deemed qualified, will issue a U.S. ATP certificate to the applicant within 30...
7 CFR 3300.70 - Issuance of certificate.
Code of Federal Regulations, 2010 CFR
2010-01-01
... BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of New Equipment § 3300.70 Issuance of certificate. The ATP manager will evaluate the documents received and, for equipment deemed qualified, will issue a U.S. ATP certificate to the applicant within 30...
7 CFR 3300.82 - Issuance of certificate.
Code of Federal Regulations, 2012 CFR
2012-01-01
... BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of Equipment in Service § 3300.82 Issuance of certificate. The ATP manager will evaluate documents received and, for equipment deemed qualified, will issue a U.S. ATP certificate to the applicant within 30...
7 CFR 3300.70 - Issuance of certificate.
Code of Federal Regulations, 2013 CFR
2013-01-01
... BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of New Equipment § 3300.70 Issuance of certificate. The ATP manager will evaluate the documents received and, for equipment deemed qualified, will issue a U.S. ATP certificate to the applicant within 30...
7 CFR 3300.82 - Issuance of certificate.
Code of Federal Regulations, 2013 CFR
2013-01-01
... BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of Equipment in Service § 3300.82 Issuance of certificate. The ATP manager will evaluate documents received and, for equipment deemed qualified, will issue a U.S. ATP certificate to the applicant within 30...
7 CFR 3300.82 - Issuance of certificate.
Code of Federal Regulations, 2011 CFR
2011-01-01
... BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of Equipment in Service § 3300.82 Issuance of certificate. The ATP manager will evaluate documents received and, for equipment deemed qualified, will issue a U.S. ATP certificate to the applicant within 30...
7 CFR 3300.82 - Issuance of certificate.
Code of Federal Regulations, 2014 CFR
2014-01-01
... BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of Equipment in Service § 3300.82 Issuance of certificate. The ATP manager will evaluate documents received and, for equipment deemed qualified, will issue a U.S. ATP certificate to the applicant within 30...
7 CFR 3300.70 - Issuance of certificate.
Code of Federal Regulations, 2011 CFR
2011-01-01
... BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of New Equipment § 3300.70 Issuance of certificate. The ATP manager will evaluate the documents received and, for equipment deemed qualified, will issue a U.S. ATP certificate to the applicant within 30...
7 CFR 3300.70 - Issuance of certificate.
Code of Federal Regulations, 2012 CFR
2012-01-01
... BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of New Equipment § 3300.70 Issuance of certificate. The ATP manager will evaluate the documents received and, for equipment deemed qualified, will issue a U.S. ATP certificate to the applicant within 30...
7 CFR 3300.82 - Issuance of certificate.
Code of Federal Regulations, 2010 CFR
2010-01-01
... BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of Equipment in Service § 3300.82 Issuance of certificate. The ATP manager will evaluate documents received and, for equipment deemed qualified, will issue a U.S. ATP certificate to the applicant within 30...
NASA Astrophysics Data System (ADS)
Hoke, Melvin D., Jr.
1988-04-01
The President's Blue Ribbon Commission on Defense Management has recommended that the military should make greater use of off-the-shelf components, systems, and services (also know as Non-Developmental Items or NDI). This recommendation, if blindly implemented, could have an adverse impact on the survivability of critical command, control, and communications assets. The study evaluates how the electromagnetic pulse (EMP) survivability of a strategic, time-urgent, fixed, ground-based, Command, Control, and Communications (C3) facility would be impacted by the use of off-the-shelf C3 equipments. The study concludes that to have a quantifiable measure of confidence in the facility's EMP survivability, the piece of off-the-shelf equipment under consideration will first have to be subjected to some degree of EMP testing.
Preventive Rad/Nuc Detection Equipment Categorization for Consequence Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buddemeier, B. R.; Musolino, S. V.; Klemic, G.
The overall objective of this project is to research, evaluate, and test first responder preventive radiological/nuclear detection equipment (PRND) to provide state and local agencies with guidance on how to best use this equipment for response after a radiological/nuclear release or detonation. While the equipment being tested in this effort has been specifically designed for detection and interdiction operations, the fleet of PRND equipment can help fill critical needs for radiological instrumentation should a consequence management response take place. This effort will provide scientific guidance on the best way to deploy and operate this class of equipment for consequence managementmore » missions. With the support of the US Department of Homeland Security’s (DHS) Domestic Nuclear Detection Office (DNDO), PRND equipment has been placed into service at federal, state, and local agencies throughout the nation. If the equipment capability and limitations are taken into account, this large inventory can be repurposed to support the emergency response in the aftermath of a radiological of nuclear event. This report evaluates PRND equipment to define key categories of equipment and the types of missions they can be used for. This is important because there are over 100 different types of PRND equipment, often with significantly different capabilities with respect to the consequence management mission. The current DNDO draft NIMS PRND equipment types were used as a foundation and expanded, when necessary, to address key characteristics important for the consequence mission. Table 1 provides a summary of the PRND instrument categories developed for this effort. Also included on the table are some common response mission detection equipment categories that will be used for capability comparisons.« less
ERIC Educational Resources Information Center
Volkwein, J. Fredericks
2010-01-01
Evaluative statements from alumni have legitimacy with both internal and external stakeholders. Thus, alumni studies can provide valuable evidence of institutional effectiveness and lend themselves to both locally designed and commercial survey instruments for data collection. Under ideal conditions, the results of alumni studies equip faculty and…
ERIC Educational Resources Information Center
Ngoungouo, Abass
2017-01-01
This paper presents the results of a study carried out on some primary and secondary schools of Yaoundé, Republic of Cameroon. The said study aimed at analyzing and evaluating the use of ICTs by teachers in the Cameroonian school system. More precisely, it sought to identify the types of ICTs used by teachers, to evaluate the state of equipment of…
Cost of ownership for inspection equipment
NASA Astrophysics Data System (ADS)
Dance, Daren L.; Bryson, Phil
1993-08-01
Cost of Ownership (CoO) models are increasingly a part of the semiconductor equipment evaluation and selection process. These models enable semiconductor manufacturers and equipment suppliers to quantify a system in terms of dollars per wafer. Because of the complex nature of the semiconductor manufacturing process, there are several key attributes that must be considered in order to accurately reflect the true 'cost of ownership'. While most CoO work to date has been applied to production equipment, the need to understand cost of ownership for inspection and metrology equipment presents unique challenges. Critical parameters such as detection sensitivity as a function of size and type of defect are not included in current CoO models yet are, without question, major factors in the technical evaluation process and life-cycle cost. This paper illustrates the relationship between these parameters, as components of the alpha and beta risk, and cost of ownership.
Fuzzy logic based sensor performance evaluation of vehicle mounted metal detector systems
NASA Astrophysics Data System (ADS)
Abeynayake, Canicious; Tran, Minh D.
2015-05-01
Vehicle Mounted Metal Detector (VMMD) systems are widely used for detection of threat objects in humanitarian demining and military route clearance scenarios. Due to the diverse nature of such operational conditions, operational use of VMMD without a proper understanding of its capability boundaries may lead to heavy causalities. Multi-criteria fitness evaluations are crucial for determining capability boundaries of any sensor-based demining equipment. Evaluation of sensor based military equipment is a multi-disciplinary topic combining the efforts of researchers, operators, managers and commanders having different professional backgrounds and knowledge profiles. Information acquired through field tests usually involves uncertainty, vagueness and imprecision due to variations in test and evaluation conditions during a single test or series of tests. This report presents a fuzzy logic based methodology for experimental data analysis and performance evaluation of VMMD. This data evaluation methodology has been developed to evaluate sensor performance by consolidating expert knowledge with experimental data. A case study is presented by implementing the proposed data analysis framework in a VMMD evaluation scenario. The results of this analysis confirm accuracy, practicability and reliability of the fuzzy logic based sensor performance evaluation framework.
Styrene vapor control systems in FRP yacht plants.
Todd, W F
1985-01-01
The production of large (greater than 25-ft) fiber-reinforced plastic (FRP) yachts has presented problems of styrene exposure in excess of the Occupational Safety and Health Administration permissible exposure level (OSHA PEL) of 100 ppm. Also, the National Institute for Occupational Safety and Health (NIOSH) is currently recommending a 10-hour workshift, 40-hour workweek time weighted average (TWA) of 50 ppm for styrene. Meeting this challenge will require a system of engineering, work practice, personal protective equipment, and monitoring control measures. NIOSH has performed a study of the engineering controls in three FRP yacht plants. Work practices and the use of personal protective equipment (PPE) were also considered in the evaluation. The three systems evaluated included a dilution system, a local ventilation system, and a push-pull ventilation system. The cost of constructing and operating these systems was not evaluated in this study. Study results indicated that each type of ventilation system can meet the present PEL of 100 ppm styrene; however, it is not certain that these systems can meet a lower PEL of 50 ppm styrene.
1982-05-01
SELECTION AND EVALUATION . . . . . . . . . . . . . . 2 2.2 MICROELECTRONIC PACKAGES AND THEIR QUALITY . . . * . . . . . . . . 5 2.3 EQUIPMENT...liquid penetrant testing for various microelectronic package hermeticity. I t I MATERIALS AND EQUIPMENT 2.1 DYE PENETRANT SELECTION AND EVALUATION...a commercial visible dye penetrant and a commercial fluorescent dye penetrant were selected as being suitable for the testing of microelectronic
DOT National Transportation Integrated Search
1987-06-01
This report presents a summary of the history and events pertinent to the Civil Aeromedical Institute's evaluation of the feasibility of providing smoke/fume protective breathing equipment for passenger use, including research undertaken, reports pro...
NASA Astrophysics Data System (ADS)
Mohamed, N.; Saman, M. Z. M.; Sharif, S.; Hamzah, H. S.
2018-03-01
While the concept of remanufacturing is gaining popularity globally, literature and theory on strategic decision-making on certifying for warranty in this area remain limited. A strategic and establish concept flow is developed based on extensive literature review and surveys with experienced experts who are dealing with remanufactured, reconditioned, rebuilt and reused components. The remanufacturing research on evaluating quality assurance of remanufactured component targets macro-level parameters and the indicators which must be confirmed for evaluation. The strategic remanufacturing factors identified from the literature review are discussed in a brainstorming session with a number of remanufacturing researchers and academic experts. The study is further broadened by industrial surveys and case studies to justify the inputs on developing a framework to certify remanufactured components. Preliminary results have established the key factors of remanufacturing quality control that might lead to the strict quality assurance of remanufactured components. Later, the developed framework can be used as a benchmarking tool to certify remanufactured components and warranty issuance. The findings serve as the foundation for further research concerning Original Equipment Manufacturer (OEM) or Original Equipment Remanufacturer (OER) and Independent Equipment Remanufacturer (IER) in the Malaysian Remanufacturing Industry.
NASA Technical Reports Server (NTRS)
Katz, U.
1982-01-01
Methods of particle generation and characterization with regard to their applicability for experiments requiring cloud condensation nuclei (CCN) of specified properties were investigated. Since aerosol characterization is a prerequisite to assessing performance of particle generation equipment, techniques for characterizing aerosol were evaluated. Aerosol generation is discussed, and atomizer and photolytic generators including preparation of hydrosols (used with atomizers) and the evaluation of a flight version of an atomizer are studied.
Nondestructive equipment study
NASA Technical Reports Server (NTRS)
1985-01-01
Identification of existing nondestructive Evaluation (NDE) methods that could be used in a low Earth orbit environment; evaluation of each method with respect to the set of criteria called out in the statement of work; selection of the most promising NDE methods for further evaluation; use of selected NDE methods to test samples of pressure vessel materials in a vacuum; pressure testing of a complex monolythic pressure vessel with known flaws using acoustic emissions in a vacuum; and recommendations for further studies based on analysis and testing are covered.
Aerial application equipment for herbicidal drift reduction.
1976-01-01
This publication provides silviculturists and managers of utility rights-of-way with a description and evaluation of available helicopter spray application equipment. Modified conventional equipment will reduce drift of sprays in normal carriers and apply various high-viscosity sprays. Specialized spray systems have found limited use in forestry; they are more commonly...
Mechanical methods of chaparral modification
George Roby; Lisle Green
1976-01-01
Chaparral modification is undertaken for a variety of land-management purposes. To help land managers in selecting equipment and methods for such work, practitioners in county, State, and Federal modification projects were asked for evaluations of equipment and techniques they had used. This handbook describes the alternative techniques and equipment, provides...
Job Aids for Using Preventive Radiological/Nuclear Detection Equipment for Consequence Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buddemeier, Brooke R.; Haynes, Daniel; Wood-Zika, Annmarie R.
The overall objective of this project is to research, evaluate, and test first responder preventive radiological/nuclear detection equipment (PRND) to provide state and local agencies with guidance on how to best use this equipment for response after a radiological/nuclear release or detonation.
30 CFR 18.5 - Equipment for which certification will be issued.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Equipment for which certification will be issued. 18.5 Section 18.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES...
30 CFR 18.21 - Machines equipped with powered dust collectors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Machines equipped with powered dust collectors. 18.21 Section 18.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES...
Free-world microelectronic manufacturing equipment
NASA Astrophysics Data System (ADS)
Kilby, J. S.; Arnold, W. H.; Booth, W. T.; Cunningham, J. A.; Hutcheson, J. D.; Owen, R. W.; Runyan, W. R.; McKenney, Barbara L.; McGrain, Moira; Taub, Renee G.
1988-12-01
Equipment is examined and evaluated for the manufacture of microelectronic integrated circuit devices and sources for that equipment within the Free World. Equipment suitable for the following are examined: single-crystal silicon slice manufacturing and processing; required lithographic processes; wafer processing; device packaging; and test of digital integrated circuits. Availability of the equipment is also discussed, now and in the near future. Very adequate equipment for most stages of the integrated circuit manufacturing process is available from several sources, in different countries, although the best and most widely used versions of most manufacturing equipment are made in the United States or Japan. There is also an active market in used equipment, suitable for manufacture of capable integrated circuits with performance somewhat short of the present state of the art.
Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations, and operation and maintenance issues
Borman Expressway Atms Equipment Evaluation; Final Report
DOT National Transportation Integrated Search
1996-08-01
AN ADVANCED TRAFFIC MANAGEMENT SYSTEM (ATMS) IS UNDER DEVELOPMENT IN NORTHERN INDIANA BY THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) IN CONJUNCTION WITH HUGHES TRANSPORTATION MANAGEMENT SYSTEMS. THE STUDY AREA COMPRISES A SIXTEEN MILE SEGMENT OF...
Nitzschke, Rainer; Doehn, Christoph; Kersten, Jan F; Blanz, Julian; Kalwa, Tobias J; Scotti, Norman A; Kubitz, Jens C
2017-04-04
The present study evaluates whether the quality of advanced cardiac life support (ALS) is improved with an interactive prototype assist device. This device consists of an automated external defibrillator linked to a ventilator and provides synchronised visual and acoustic instructions for guidance through the ALS algorithm and assistance for face-mask ventilations. We compared the cardiopulmonary resuscitation (CPR) quality of emergency medical system (EMS) staff members using the study device or standard equipment in a mannequin simulation study with a prospective, controlled, randomised cross-over study design. Main outcome was the effect of the study device compared to the standard equipment and the effect of the number of prior ALS trainings of the EMS staff on the CPR quality. Data were analysed using analyses of covariance (ANCOVA) and binary logistic regression, accounting for the study design. In 106 simulations of 56 two-person rescuer teams, the mean hands-off time was 24.5% with study equipment and 23.5% with standard equipment (Difference 1.0% (95% CI: -0.4 to 2.5%); p = 0.156). With both types of equipment, the hands-off time decreased with an increasing cumulative number of previous CPR trainings (p = 0.042). The study equipment reduced the mean time until administration of adrenaline (epinephrine) by 23 s (p = 0.003) and that of amiodarone by 17 s (p = 0.016). It also increased the mean number of changes in the person doing chest compressions (0.6 per simulation; p < 0.001) and decreased the mean number of chest compressions (2.8 per minute; p = 0.022) and the mean number of ventilations (1.8 per minute; p < 0.001). The chance of administering amiodarone at the appropriate time was higher, with an odds ratio of 4.15, with the use of the study equipment CPR.com compared to the standard equipment (p = 0.004). With an increasing number of prior CPR trainings, the time intervals in the ALS algorithm until the defibrillations decreased with standard equipment but increased with the study device. EMS staff with limited training in CPR profit from guidance through the ALS algorithm by the study device. However, the study device somehow reduced the ALS quality of well-trained rescuers and thus can only be recommended for ALS provider with limited experience.
Dosimetry and image quality assessment in a direct radiography system
Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro
2014-01-01
Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119
Pilot Evaluation of an Internet Educational Module for Agricultural Safety
ERIC Educational Resources Information Center
Schwab, Charles V.; Freeman, Steven A.
2011-01-01
An important component of the safe operation of agricultural equipment is the ability to read and understand universal symbols. The Internet educational module is designed to help participants recognize these symbols. The impact of using it was evaluated using a field trial study. Assessment consisted of pre- and post-tests. Youth who had access…
Evaluation of two round baling systems for harvesting understory biomass
J.L. do Canto; John Klepac; Robert Rummer; P. Savoie; F. Seixas
2011-01-01
The objective of this study was to evaluate the performance and to estimate costs of two round baling systems for harvesting understory biomass. One system was a cutter-shredderbaler prototype (Bio-baler). The other system required two successive operations. The first operation was cutting and shredding with a Supertrak tractor equipped with a Fecon mulcher head. The...
Evaluation of the Redesign of an Undergraduate Cell Biology Course
ERIC Educational Resources Information Center
McEwen, Laura April; Harris, dik; Schmid, Richard F.; Vogel, Jackie; Western, Tamara; Harrison, Paul
2009-01-01
This article offers a case study of the evaluation of a redesigned and redeveloped laboratory-based cell biology course. The course was a compulsory element of the biology program, but the laboratory had become outdated and was inadequately equipped. With the support of a faculty-based teaching improvement project, the teaching team redesigned the…
Prioritizing equipment for replacement.
Capuano, Mike
2010-01-01
It is suggested that clinical engineers take the lead in formulating evaluation processes to recommend equipment replacement. Their skill, knowledge, and experience, combined with access to equipment databases, make them a logical choice. Based on ideas from Fennigkoh's scheme, elements such as age, vendor support, accumulated maintenance cost, and function/risk were used.6 Other more subjective criteria such as cost benefits and efficacy of newer technology were not used. The element of downtime was also omitted due to the data element not being available. The resulting Periop Master Equipment List and its rationale was presented to the Perioperative Services Program Council. They deemed the criteria to be robust and provided overwhelming acceptance of the list. It was quickly put to use to estimate required capital funding, justify items already thought to need replacement, and identify high-priority ranked items for replacement. Incorporating prioritization criteria into an existing equipment database would be ideal. Some commercially available systems do have the basic elements of this. Maintaining replacement data can be labor-intensive regardless of the method used. There is usually little time to perform the tasks necessary for prioritizing equipment. However, where appropriate, a clinical engineering department might be able to conduct such an exercise as shown in the following case study.
E-waste management and sustainability: a case study in Brazil.
Azevedo, Luís Peres; da Silva Araújo, Fernando Gabriel; Lagarinhos, Carlos Alberto Ferreira; Tenório, Jorge Alberto Soares; Espinosa, Denise Crocce Romano
2017-11-01
The advancement of technology and development of new electronic and electrical equipment with a reduced life cycle has increased the need for the disposal of them (called Waste of Electric and Electronic Equipment or simply e-waste) due to defects presented during use, replacement of obsolete equipment, and ease of acquisition of new equipment. There is a lack of consumer awareness regarding the use, handling storage, and disposal of this equipment. In Brazil, the disposal of post-consumer waste is regulated by the National Solid Waste Policy, established by Law No. 12305 and regulated on the 23rd December 2010. Under this legislation, manufacturers and importers are required to perform a project for the Reverse Logistics of e-waste, though its implementation is not well defined. This work focuses on the verification of the sustainability of reverse logistics suggested by the legislation and the mandatory points, evaluating its costs and the possible financial gain with recycling of the waste. The management of reverse logistics and recycling of waste electrical and electronic equipment, or simply recycling of e-waste, as suggested by the government, will be the responsibility of the managing organization to be formed by the manufacturers/importers in Brazil.
Ramirez, Marizen; Bedford, Ronald; Wu, Hongqian; Harland, Karisa; Cavanaugh, Joseph E; Peek-Asa, Corinne
2016-01-01
Objective To evaluate the effectiveness of roadway policies for lighting and marking of farm equipment in reducing crashes in Illinois, Iowa, Kansas, Minnesota, Missouri, Nebraska, North Dakota, South Dakota and Wisconsin. Methods In this ecological study, state policies on lighting and marking of farm equipment were scored for compliance with standards of the American Society of Agricultural and Biological Engineers (ASABE). Using generalized estimating equations negative binomial models, we estimated the relationships between lighting and marking scores, and farm equipment crash rates, per 100 000 farm operations. Results A total of 7083 crashes involving farm equipment was reported from 2005 to 2010 in the Upper Midwest and Great Plains. As the state lighting and marking score increased by 5 units, crash rates reduced by 17% (rate ratio=0.83; 95% CI 0.78 to 0.88). Lighting-only (rate ratio=0.48; 95% CI 0.45 to 0.51) and marking-only policies (rate ratio=0.89; 95% CI 0.83 to 0.96) were each associated with reduced crash rates. Conclusions Aligning lighting and marking policies with ASABE standards may effectively reduce crash rates involving farm equipment. PMID:27405602
Vincent, Christopher James; Blandford, Ann
2017-03-01
We present findings of a UK study into how those involved in purchasing interactive medical devices go about evaluating usability, the challenges that arise, and opportunities for improvement. The study focused on procurement of infusion devices because these are used by various professionals across healthcare. A semi-structured interview study was carried out involving a range of stakeholders (20 in total) involved in or impacted by medical device procurement. Data was analysed using thematic analysis, a qualitative method designed to support the identification, analysis and reporting of patterns. In principle, health service purchasing was found to accommodate consideration of equipment usability. In practice, the evaluation process was driven primarily by engineering standards; assessment of local needs did not accommodate substantive assessment of usability; and choice was limited by the availability of equipment on the marketplace. We discuss ways in which purchasing could be improved through techniques that account for social circumstances. Copyright © 2016 Elsevier Ltd. All rights reserved.
Shared Care of Childhood Cancer Survivors: A Telemedicine Feasibility Study.
Costello, Aimee G; Nugent, Bethany D; Conover, Noelle; Moore, Amanda; Dempsey, Kathleen; Tersak, Jean M
2017-12-01
With an increasing number of childhood cancer survivors (CCSs), determining the best model of survivorship transition care is becoming a growing priority. Shared care between pediatric oncology and adult primary care is often necessary, making survivorship a time of transition, but effective standard models are lacking. We sought to provide a more integrated approach to transition using telemedicine. Recruited primary care provider/CCS dyads were instructed to log-in to a password-protected virtual meeting room using telemedicine equipment at the time or a regularly scheduled office visit. Dyads were joined by a pediatric survivorship clinic team member who conducted the telemedicine portion of the transition visit, which consisted of the review of an individualized treatment summary and care plan. Postquestionnaires were developed to evaluate key points such as fund of knowledge, satisfaction with the visit, and effectiveness of this electronic tool. There were 19 transition visits conducted, 13 of which used the telemedicine equipment as planned. Those that did not use the equipment were primarily unable to due to technical difficulties. Postquestionnaires were overall positive, confirming increased knowledge, comfort and abilities, and patient satisfaction in survivorship care. Negative comments were primarily related to equipment difficulties. A gap still remains in helping CCSs transition from oncology to primary care and this pilot study offered insights into how we might better bridge that gap through the use of telemedicine. Further research is needed to refine the transition process for CCSs, including evaluation and testing models for standard of care.
Criteria-based evaluation of group 3 level memory telefacsimile equipment for interlibrary loan.
Bennett, V M; Wood, M S; Malcom, D L
1990-01-01
The Interlibrary Loan, Document Delivery, and Union List Task Force of the Health Sciences Libraries Consortium (HSLC)--with nineteen libraries located in Philadelphia, Pittsburgh, and Hershey, Pennsylvania, and Delaware--accepted the charge of evaluating and recommending for purchase telefacsimile hardware to further interlibrary loan among HSLC members. To allow a thorough and scientific evaluation of group 3 level telefacsimile equipment, the task force identified ninety-six hardware features, which were grouped into nine broad criteria. These features formed the basis of a weighted analysis that identified three final candidates, with one model recommended to the HSLC board. This article details each of the criteria and discusses features in terms of library applications. The evaluation grid developed in the weighted analysis process should aid librarians charged with the selection of level 3 telefacsimile equipment. PMID:2328361
Evaluating the Validity of the U.S. Military’s Global Empire
2015-03-26
With this status came an unchecked and impressive global force posture . While the United States dramatically cut the number of personnel in Western...evaluates the currant pre-positioned equipment concepts, and evaluates Operation Enduring Freedom (Afghanistan) as a case study for Force Posture . The...conclusion offers five recommendations for the future of United States global force posture and actions that support access. 15. SUBJECT TERMS 16
Anthropometric Procedures for Protective Equipment Sizing and Design
Hsiao, Hongwei
2015-01-01
Objectives This article presented four anthropometric theories (univariate, bivariate/probability distribution, multivariate, and shape-based methods) for protective equipment design decisions. Background While the significance of anthropometric information for product design is well recognized, designers continue to face challenges in selecting efficient anthropometric data processing methods and translating the acquired information into effective product designs. Methods For this study, 100 farm tractor operators, 3,718 respirator users, 951 firefighters, and 816 civilian workers participated in four studies on the design of tractor roll-over protective structures (ROPS), respirator test panels, fire truck cabs, and fall-arrest harnesses, respectively. Their anthropometry and participant-equipment interfaces were evaluated. Results Study 1 showed a need to extend the 90-cm vertical clearance for tractor ROPS in the current industrial standards to 98.3 to 101.3 cm. Study 2 indicated that current respirator test panel would have excluded 10% of the male firefighter population; a systematic adjustment to the boundaries of test panel cells was suggested. Study 3 provided 24 principal component analysis-based firefighter body models to facilitate fire truck cab design. Study 4 developed an improved gender-based fall-arrest harness sizing scheme to supplant the current unisex system. Conclusions This article presented four anthropometric approaches and a six-step design paradigm for ROPS, respirator test panel, fire truck cab, and fall-arrest harness applications, which demonstrated anthropometric theories and practices for defining protective equipment fit and sizing schemes. Applications The study provided a basis for equipment designers, standards writers, and industry manufacturers to advance anthropometric applications for product design and improve product efficacy. PMID:23516791
RADC thermal guide for reliability engineers
NASA Astrophysics Data System (ADS)
Morrison, G. N.; Kallis, J. M.; Strattan, L. A.; Jones, I. R.; Lena, A. L.
1982-06-01
This guide was developed to provide a reliability engineer, who is not proficient in thermal design and analysis techniques, with the tools for managing and evaluating the thermal design and production of electronic equipment. It defines the requirements and tasks that should be addressed in system equipment specifications and statements of work, and describes how to evaluate performance.
Art Teaching Guides: Painting. Kindergarten-Grade 6. Curriculum Bulletin. No. 8 g. 1968-69 Series.
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn, NY. Div. of Curriculum and Instruction.
Growth in painting ability is dependent on frequent painting experiences, on thoughtful motivation, and on proper guidance and evaluation of progress. This guide includes materials and equipment, motivation, guidance procedures, activities, and evaluation for each grade level. A working space with materials and equipment in the classroom needs to…
ATLS: Catheter and tube placement
NASA Technical Reports Server (NTRS)
Gosbee, John; Krupa, Debra T.; Pepper, L.; Orsak, Debra
1991-01-01
The specific objectives of this experiment are: to evaluate the rack mounted equipment and medical supplies necessary for medical procedures; to evaluate the attachments, mounting points, and inner drawer assemblies for the medical supplies; and to evaluate the procedures for performing medical scenarios. The resources available in the HMF miniracks to accomplish medical scenarios and/or procedures include: medical equipment mounted in the racks; a patch panel with places to attach tubing and catheters; self contained drawers full of critical care medical supplies; and an ALS 'backpack' for deploying supplies. The attachment lines, tubing and associated medical supplies will be deployed and used with the equipment and a patient mannequin. Data collection is provided by direct observations by the inflight experimenters, and analysis of still and video photography.
Seismic verification of nuclear plant equipment anchorage, Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Czarnecki, R M
1991-06-01
Guidelines have been developed to evaluate the seismic adequacy of the anchorage of various classes of electrical and mechanical equipment in nuclear power plants covered by NRC Unresolved Safety Issue A-46. The guidelines consist of anchorage strength capacities as a function of key equipment and installation parameters. The strength criteria for expansion anchor bolts were developed by collecting and analyzing a large quantity of test data. The strength criteria for Cast-in-Place bolts and welds to embedded steel plates and channels were taken from existing nuclear-industry design guidelines. For anchorage used in low strength concrete and in concrete with cracks, appropriatemore » strength reduction factors were developed. Reduction factors for parameters such as edge distance, spacing and embedment depth are also included. Based on the anchorage capacity and equipment configuration, inspection checklists for field verification of anchorage adequacy were developed, and provisions for outliners that can be used to further investigate anchorages that cannot be verified in the field were prepared. The screening tables are based on an analysis of the anchorage forces developed by common equipment types and on strength criteria to quantify the holding power of anchor bolts and welds. A computer code EBAC was developed for the evaluation of the adequacy of the equipment anchorage. Guidelines to evaluate anchorage adequacy for vertical and horizontal tanks and horizontal heat exchangers were also developed.« less
Planning, expectation, and image evaluation for PACS at the University of Iowa Hospitals and Clinics
NASA Astrophysics Data System (ADS)
Franken, E. A., Jr.; Smith, Wilbur L.; Berbaum, Kevin S.; Owen, David A.; Hilsenrath, Peter
1990-08-01
Our strategy in studying PACS is to evaluate its clinical implementation working with equipment supplied by an established manufacturer. Fiscal and personnel resources required to design and integrate the hardware components and operational software to develop a functional PACS precluded a bottom up development approach at our institution. Imaging equipment vendors possess more abundant design development resources for this task and therefore can support a more rapid development of the initial components of PACS. For this reason we have chosen to serve as a beta test site to study the viability of the basic PACS components in a clinical setting. Our efforts primarily focus on: (1) image quality; (2) cost effectiveness; (3) PACS/HIS/RIS integration; (4) equipment and software reliability; and (5) overall system performance. The results of our studies are shared with the vendor for future PACS development and refi nement. To attain our investigational goals we have formed an interdisciplinary team of Radiologists, Perceptual Psychologist, Economist, Electrical and Industrial Engineers, Hospital Information System personnel and key departmental administrative staff. For several reasons Pediatric Radiology was targeted as the initial area for our PACS study: a small area representative of the overall operation,tight operational controls and willingness of physicians. We used a step-wise approach, the first step being the installation of PACS exclusively within the physical confines of Pediatric Radiology.
ERIC Educational Resources Information Center
Technical Education Research Center, Cambridge, MA.
OFFICIALS OF A REPRESENTATIVE SAMPLE OF HOSPITALS, BIOMEDICAL EQUIPMENT MANUFACTURERS, AND MEDICAL RESEARCH INSTITUTES IN NEW ENGLAND AND THREE MIDDLE ATLANTIC STATES WERE INTERVIEWED TO DETERMINE THE NEED FOR TECHNICIANS TO SERVICE AND MAINTAIN EQUIPMENT FOUND IN HOSPITALS AND BIOMEDICAL RESEARCH INSTITUTIONS. RESPONSES INDICATED A NEED FOR…
10 CFR 603.535 - Value of proposed real property or equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Value of proposed real property or equipment. 603.535... AGREEMENTS Pre-Award Business Evaluation Cost Sharing § 603.535 Value of proposed real property or equipment. The contracting officer rarely should accept values for cost sharing contributions of real property or...
Risk based inspection for atmospheric storage tank
NASA Astrophysics Data System (ADS)
Nugroho, Agus; Haryadi, Gunawan Dwi; Ismail, Rifky; Kim, Seon Jin
2016-04-01
Corrosion is an attack that occurs on a metallic material as a result of environment's reaction.Thus, it causes atmospheric storage tank's leakage, material loss, environmental pollution, equipment failure and affects the age of process equipment then finally financial damage. Corrosion risk measurement becomesa vital part of Asset Management at the plant for operating any aging asset.This paper provides six case studies dealing with high speed diesel atmospheric storage tank parts at a power plant. A summary of the basic principles and procedures of corrosion risk analysis and RBI applicable to the Process Industries were discussed prior to the study. Semi quantitative method based onAPI 58I Base-Resource Document was employed. The risk associated with corrosion on the equipment in terms of its likelihood and its consequences were discussed. The corrosion risk analysis outcome used to formulate Risk Based Inspection (RBI) method that should be a part of the atmospheric storage tank operation at the plant. RBI gives more concern to inspection resources which are mostly on `High Risk' and `Medium Risk' criteria and less on `Low Risk' shell. Risk categories of the evaluated equipment were illustrated through case study analysis outcome.
Survey of injury sources for a trampoline with equipment hazards designed out.
Eager, David; Scarrott, Carl; Nixon, Jim; Alexander, Keith
2012-07-01
In Australia, trampolines contribute approximately one-quarter of all childhood play-equipment injuries. The purpose of this study was to gather and evaluate injury data from a nontraditional, 'soft-edged', consumer trampoline in which the equipment injury sources have been designed out. A survey was undertaken in Queensland and New South Wales. The manufacturer of the nontraditional trampoline provided the University of Technology, Sydney, with their Australian customer database. Injury data were gathered in a pilot study by phone interview, then in a full study through an email survey. Results from 3817 respondents were compared with earlier Australian and US data from traditional trampolines gathered from emergency departments. A significantly lower proportion of the injuries caused by falling off or striking the equipment was found for this new design when compared with traditional trampolines both in Australia and in the USA. The age of children being injured on trampolines in Australia was found to be markedly lower than in North America. This research indicates that with appropriate design the more severe injuries on traditional trampolines can be significantly reduced. © 2012 The Authors. Journal of Paediatrics and Child Health © 2012 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Use of personal protective equipment for respiratory protection.
Sargent, Edward V; Gallo, Frank
2003-01-01
Management of hazards in biomedical research facilities requires the application of the traditional industrial hygiene responsibilities of anticipation, recognition, evaluation, and control to characterize the work environment, evaluate tasks and equipment, identify hazards, define exposure groups, and recommend controls. Generally, the diversity and unique characteristics of hazards faced by laboratory and animal facility employees and the short-term and low-level nature of the exposures factor into the selection of proper exposure control measures in the laboratory. The proper selection of control measures is based on a hierarchy of elimination and minimization by engineering controls, followed last by personal protective equipment when exposures cannot be eliminated. Once it is decided that personal protective equipment is needed, specific regulations and guidelines define safety standards for research facilities, including the elements of a sound respiratory protection program. These elements include respirator selection (including appropriate protection factors), medical evaluation, fit testing, training, inspection, maintenance and care, quality, quantity and flow of breathing air, and routine and emergency use procedures.
High-speed texture measurement of pavements.
DOT National Transportation Integrated Search
2003-01-01
This study was conducted to validate high-speed texture measuring equipment for use in highway applications. The evaluation included two high-speed systems and a new static referencing device. Tests were conducted on 22 runway and taxiway test sectio...
Communications systems technology assessment study. Volume 2: Results
NASA Technical Reports Server (NTRS)
Kelley, R. L.; Khatri, R. K.; Kiesling, J. D.; Weiss, J. A.
1977-01-01
The cost and technology characteristics are examined for providing special satellite services at UHF, 2.5 GHz, and 14/12 GHz. Considered are primarily health, educational, informational and emergency disaster type services. The total cost of each configuration including space segment, earth station, installation operation and maintenance was optimized to reduce the user's total annual cost and establish preferred equipment performance parameters. Technology expected to be available between now and 1985 is identified and comparisons made between selected alternatives. A key element of the study is a survey of earth station equipment updating past work in the field, providing new insight into technology, and evaluating production and test methods that can reduce costs in large production runs. Various satellite configurations were examined. The cost impact of rain attenuation at Ku-band was evaluated. The factors affecting the ultimate capacity achievable with the available orbital arc and available bandwidth were analyzed.
Effect of dissolved oxygen level of water on ultrasonic power measured using calorimetry
NASA Astrophysics Data System (ADS)
Uchida, Takeyoshi; Yoshioka, Masahiro; Horiuchi, Ryuzo
2018-07-01
Ultrasonic therapeutic equipment, which exposes the human body to high-power ultrasound, is used in clinical practice to treat cancer. However, the safety of high-power ultrasound has been questioned because the equipment affects not only cancer cells but also normal cells. To evaluate the safety of ultrasound, it is necessary to accurately measure the ultrasonic power of the equipment. This is because ultrasonic power is a key quantity related to the thermal hazard of ultrasound. However, precise techniques for measuring ultrasonic power in excess of 15 W are yet to be established. We have been studying calorimetry as a precise measurement technique. In this study, we investigated the effect of the dissolved oxygen (DO) level of water on ultrasonic power by calorimetry. The results show that the measured ultrasonic power differed significantly between water samples of different DO levels. This difference in ultrasonic power arose from acoustic cavitation.
Analysis of remote operating systems for space-based servicing operations. Volume 2: Study results
NASA Technical Reports Server (NTRS)
1985-01-01
The developments in automation and robotics have increased the importance of applications for space based servicing using remotely operated systems. A study on three basic remote operating systems (teleoperation, telepresence and robotics) was performed in two phases. In phase one, requirements development, which consisted of one three-month task, a group of ten missions were selected. These included the servicing of user equipment on the station and the servicing of the station itself. In phase two, concepts development, which consisted of three tasks, overall system concepts were developed for the selected missions. These concepts, which include worksite servicing equipment, a carrier system, and payload handling equipment, were evaluated relative to the configurations of the overall worksite. It is found that the robotic/teleoperator concepts are appropriate for relatively simple structured tasks, while the telepresence/teleoperator concepts are applicable for missions that are complex, unstructured tasks.
Calder, W.; Snyder, D.; Burr, J.F.
2018-01-01
This paper provides a determination of the equivalent level of protection of the international standards relative to similar criteria used by the U.S. Mine Safety and Health Administration (MSHA) to approve two-fault intrinsically safe (IS) stand-alone equipment. U.S. mining law requires such a determination for MSHA to use alternatives to existing standards. The primary issue is to demonstrate that the international standards for equipment evaluation will provide at least the same level of protection for miners as the document currently used by MSHA. PMID:29780219
Map Study Committee. Final Report.
ERIC Educational Resources Information Center
Heidlage, Bob; And Others
A study undertaken to evaluate the status of the University of Missouri-Columbia's map collections is described in this report, and forecasts are made for necessary facilities, equipment, and personnel to accomplish a proposed reorganization and online cataloging of the university's geology and geography map collections. Included in plans for…
Study of Mechanization in DOD Libraries and Information Centers.
ERIC Educational Resources Information Center
Booz, Allen Applied Research, Inc., Bethesda, MD.
This report summarizes the on-site study of mechanization in DoD libraries and information centers. Included are presentations and evaluations on thesaurus building, file structure, input processing, serial control, selective dissemination of information, circulation control, equipments being used, recommendations on information retrieval systems,…
36 CFR 1193.23 - Product design, development, and evaluation.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., usability, and compatibility of telecommunications equipment and customer premises equipment and shall... as possible. Manufacturers shall identify barriers to accessibility and usability as part of such a...
Venturini, Sara; Park, Kee B
2018-01-01
Surgical practice highly depends on the availability of surgical equipment; this is particularly relevant to low- and middle-income countries (LMICs), where resources are limited. A key part of the efforts to improve surgical provision globally include providing affordable equipment to LMICs; however, the effectiveness and the impact of these initiatives have not yet been assessed. We aimed to evaluate the World Federation of Neurosurgical Societies neurosurgical equipment program in this context. Recipients were identified from the World Federation of Neurosurgical Societies records; contact details were gathered. An online survey was used to collect data on equipment, including its current use, any malfunctioning issues, suitability, reliability, serviceability, and the impact it has had on the unit. Responses were received from 16 units, totaling 28 pieces of equipment. A total of 75% of the equipment is still in use; of this, 57% is fully functioning, and 43% is used despite some malfunction. We found that 25% of the equipment is broken and unusable; high-maintenance items, such as high-speed drills, feature in this category (100% broken, n = 3). Units reported an increase in number of operation performed in 74% cases, improved surgery quality in 78%, and breadth of operations in 44%. Satisfaction, equipment suitability, reliability, and serviceability scored highly, with median values of 9 for all fields on a 10-point scale. Equipment donation positively impacts neurosurgical units in LMICs by allowing expansion of neurosurgical practice, improved safety and quality, and affordability. Adequate follow-up, considerations regarding equipment durability and maintenance needs, and improved support for repairs should be prioritized to ensure maximal benefit. Copyright © 2017 Elsevier Inc. All rights reserved.
75 FR 70696 - QPS Evaluation Services Inc.; Application for Recognition
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-18
... of Canada and the International Electrotechnical Commission Certification Body (IEC CB) Scheme). QPS... Information Technology Equipment. UL 61010-1 Electrical Equipment for Measurement, Control, and Laboratory Use...
36 CFR § 1193.23 - Product design, development, and evaluation.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., usability, and compatibility of telecommunications equipment and customer premises equipment and shall... as possible. Manufacturers shall identify barriers to accessibility and usability as part of such a...
Review: The use of bull breeding soundness evaluation to identify subfertile and infertile bulls.
Barth, A D
2018-06-01
Efficient and economical herd management depends a great deal on maintaining a short, well-defined calving season. This requires highly fertile females and bulls. Low pregnancy rates are very noticeable, however; potentially greater economic loss may be due to delayed conception. Many studies showed that approximately one of every five bulls had inadequate semen quality, physical soundness, or both, but when evaluation of serving capacity is included about one in four bulls is unsatisfactory. Due mainly to the time and expense that the market will bear, usually only physical soundness and semen quality are evaluated. Breeding soundness evaluation is a useful, low-cost screening method for reducing the risk of using low fertility bulls. The biggest problem with breeding soundness evaluations is not our lack of knowledge or ability, but in the willingness of veterinary schools to provide adequate equipment and training in this area, a lack of diagnostic laboratories equipped to handle the more difficult cases and, most importantly, the weaknesses of human nature that result in negligent testing procedure.
Selecting the right ultrasound equipment--an administrator's perspective.
Jacoby, Robert
2003-01-01
Recent advancements in ultrasound equipment, technology and capability make the selection of new or replacement equipment a difficult task. It is not uncommon that the sonographers will have different needs and wants from the equipment than do the radiologists. This potential hurdle needs to be addressed in order to arrive at a mutually acceptable selection. Vendors across the board all have very competitive products and they each have that special little "function" or "enhancement" that sets them apart from their competitor. The customer needs to approach the evaluation of the equipment in a very objective manner in order to truly understand not only the differences of each piece of equipment but the actual capability of each piece of equipment. In the end however, it is the individual sonographer that will be utilizing the equipment most of the time and they should have the final say to department management as to which equipment is selected.
Future development of IR thermovision weather satellite equipment
NASA Technical Reports Server (NTRS)
Listratov, A. V.
1974-01-01
The self radiation of the surface being viewed is used for image synthesis in IR thermovision equipment. The installation of such equipment aboard weather satellites makes it possible to obtain cloud cover pictures of the earth's surface in a complete orbit, regardless of the illumination conditions, and also provides quantitative information on the underlying surface temperature and cloud top height. Such equipment is used successfully aboard the Soviet satellites of the Meteor system, and experimentally on the American satellites of the Nimbus series. With regard to surface resolution, the present-day IR weather satellite equipment is inferior to the television equipment. This is due primarily to the comparatively low detectivity of the IR detectors used. While IR equipment has several fundamental advantages in comparison with the conventional television equipment, the problem arises of determining the possibility for future development of weather satellite IR thermovision equipment. Criteria are examined for evaluating the quality of IR.
Busch, Christian Werner; Qalanawi, Mohammed; Kersten, Jan Felix; Kalwa, Tobias Johannes; Scotti, Norman Alexander; Reip, Wikhart; Doehn, Christoph; Maisch, Stefan; Nitzschke, Rainer
2015-10-01
Medical teams with limited experience in performing advanced life support (ALS) or with a low frequency of cardiopulmonary resuscitation (CPR) while on duty, often have difficulty complying with CPR guidelines. This study evaluated whether the quality of CPR of trained medical students, who served as an example of teams with limited experience in ALS, could be improved with device assistance. The primary outcome was the hands-off time (i.e., the percentage of the entire CPR time without chest compressions). The secondary outcome was seven time intervals, which should be as short as possible, and the quality of ventilations and chest compressions on the mannequin. We compared standard CPR equipment to an interactive device with visual and acoustic instructions for ALS workflow measures to guide briefly trained medical students through the ALS algorithm in a full-scale mannequin simulation study with a randomized crossover study design. The study equipment consisted of an automatic external defibrillator and ventilator that were electronically linked and communicating as a single system. Included were regular medical students in the third to sixth years of medical school of one class who provided written informed consent for voluntary participation and for the analysis of their CPR performance data. No exclusion criteria were applied. For statistical measures of evaluation we used an analysis of variance for crossover trials accounting for treatment effect, sequence effect, and carry-over effect, with adjustment for prior practical experience of the participants. Forty-two medical students participated in 21 CPR sessions, each using the standard and study equipment. Regarding the primary end point, the study equipment reduced the hands-off time from 40.1% (95% confidence interval [CI] 36.9-43.4%) to 35.6% (95% CI 32.4-38.9%, p = 0.031) compared with the standard equipment. Within the prespecified secondary end points, study equipment reduced the time interval until the first rescuer changeover from 273 s (95% CI 244-302 s) to 223 s (95% CI 194-253 s, p = 0.001) and increased the percentage of ventilations with a correct tidal volume of 400-600 mL from 34.3% (95% CI 19.0-49.6%) to 60.9% (95% CI 45.6-76.2%, p = 0.018). The assist device increased the rescuers' CPR quality. CPR providers with limited experience or a limited frequency of CPR performance (i.e., rural Emergency Medical Services crew) may potentially benefit from this assist device. Copyright © 2015 Elsevier Inc. All rights reserved.
Evaluating Management Strategies for Automated Test Systems/Equipment (ATS/E): An F-15 Case Study
2005-03-01
ethnography , grounded theory , case study , phenomenological research , and narrative research (also known as bibliography from...Creswell, 2003:183). Example inquiry strategies identified by Creswell are: narrative , phenomenology , ethnography , case study , and grounded theory ...other managed systems. Methodology The researcher chose a qualitative research methodology and
NASA Astrophysics Data System (ADS)
Domat, M.; Pla, J.; Cadavid-Rodríguez, M. C.; Fito, C.
2017-06-01
The rapid expansion of nanotechnology is outpacing health and safety recommendations for engineered nanomaterials. Thus, there is a lack of information about the effects that nanomaterials can induce in the human health. Nevertheless, workers in nanotechnology-related industries are potentially at risk of being exposed to nanomaterials. Therefore, there is a need of characterize the behaviour of personal protective equipment against penetration nanoparticles, in order to provide an adequate protection to the workers. In this study, the efficiency of several protective dermal equipment against water-based NaCl aerosol was evaluated. For this purpose, different protective clothing and gloves were selected to carry out the assays, simulating typical use conditions of protective equipment under occupational settings. Results obtained exposed that the level of protection offered by the distinct types of personal protective coveralls depended not only on the fabric, but also on their fitting to the body of the subject. On the other hand, the efficiency of the protective gloves was set in the range from 95% to 99%, depending on the thickness and the type of material.
Passive Vibration Control of Airborne Equipment using a Circular Steel Ring
NASA Technical Reports Server (NTRS)
Ellison, Joseph; Ahmadi, Goodarz; Kehoe, Mike
1997-01-01
Vibration isolation is needed to protect avionics equipment from adverse aircraft vibration environments. Passive isolation is the simplest means to achieve this goal. The system used here consists of a circular steel ring with a lump mass on top and exposed to base excitation. Sinusoidal and filtered zero-mean Gaussian white noise are used to excite the structure and the acceleration response spectra at the top of the ring are computed. An experiment is performed to identify the natural frequencies and modal damping of the circular ring. Comparison is made between the analytical and experimental results and good agreement is observed. The ring response is also evaluated with a concentrated mass attached to the top of the ring. The effectiveness of the ring in isolating the equipment from base excitation is studied. The acceleration response spectra of a single degree of freedom system attached to the top of the ring are evaluated and the results are compared with those exposed directly to the base excitation. It is shown that a properly designed ring could effectively protect the avionics from possible damaging excitation levels.
Best practices and strategies for improving rail energy efficiency
DOT National Transportation Integrated Search
2014-01-28
In support of the FRA Energy, Environment, and Engine (E3) program, this study reviews and evaluates technology development opportunities, equipment upgrades, and best practices (BPs) of international and U.S. passenger and freight rail industry segm...
Implementation of Testing Equipment for Asphalt Materials : Tech Summary
DOT National Transportation Integrated Search
2009-05-01
Three new automated methods for related asphalt material and mixture testing were evaluated under this study. Each of these devices is designed to reduce testing time considerably and reduce operator error by automating the testing process. The Thery...
Implementation of testing equipment for asphalt materials : tech summary.
DOT National Transportation Integrated Search
2009-05-01
Three new automated methods for related asphalt material and mixture testing were evaluated : under this study. Each of these devices is designed to reduce testing time considerably and reduce : operator error by automating the testing process. The T...
Evaluation of Commercially-Available Equipment for the ...
Report The Underground Transport Restoration (UTR) project is an inter-agency effort. This effort aims to improve the capability for transit systems to quickly and efficiently recover from a biological contamination incident by refining existing methods, tools and protocols for characterization, clean-up, and clearance of contamination in physical structures (i.e., tunnels, stations) and rolling stock (i.e., subway trains). The aim was to evaluate existing sampling, characterization, and decontamination technologies through experimentation, table-top exercises and operational demonstrations to develop guidance and decision frameworks and support tools through interactions of local, state and federal partners. In this investigation, a survey of commercially-available or fielded equipment was conducted and resulted in three pieces of identified equipment that could be used or rapidly modified for use in dispensing liquid chemicals to decontaminate surfaces following a biological contamination incident. documenting lab-scale testing, field-scale testing, and an equipment demonstration of commercial equipment used to decontaminate subway infrastructure following a biological incident.
Shah, Ruchi R; Dodd, Stephanie; Schaefer, Mary; Ugozzoli, Mildred; Singh, Manmohan; Otten, Gillis R; Amiji, Mansoor M; O'Hagan, Derek T; Brito, Luis A
2015-04-01
Microfluidization is an established technique for preparing emulsion adjuvant formulations for use in vaccines. Although this technique reproducibly yields high-quality stable emulsions, it is complex, expensive, and requires proprietary equipment. For this study, we developed a novel and simple low shear process to prepare stable reproducible emulsions without the use of any proprietary equipment. We found this process can produce a wide range of differently sized emulsions based on the modification of ratios of oil and surfactants. Using this process, we prepared a novel 20-nm-sized emulsion that was stable, reproducible, and showed adjuvant effects. During evaluation of this emulsion, we studied a range of emulsions with the same composition all sized below 200; 20, 90, and 160 nm in vivo and established a correlation between adjuvant size and immune responses. Our studies indicate that 160-nm-sized emulsions generate the strongest immune responses. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Industrial laser welding evaluation study
NASA Technical Reports Server (NTRS)
Hella, R.; Locke, E.; Ream, S.
1974-01-01
High power laser welding was evaluated for fabricating space vehicle boosters. This evaluation was made for 1/4 in. and 1/2 in. aluminum (2219) and 1/4 in. and 1/2 in. D6AC steel. The Avco HPL 10 kW industrial laser was used to perform the evaluation. The objective has been achieved through the completion of the following technical tasks: (1) parameter study to optimize welding and material parameters; (2) preparation of welded panels for MSFC evaluation; and (3) demonstration of the repeatability of laser welding equipment. In addition, the design concept for a laser welding system capable of welding large space vehicle boosters has been developed.
Development of a Methodology for Assessing Aircrew Workloads.
1981-11-01
Workload Feasibility Study. .. ...... 52 Subjects. .. .............. ........ 53 Equipment .. ............... ....... 53 Date Analysis ... analysis ; simulation; standard time systems; switching synthetic time systems; task activities; task interference; time study; tracking; workload; work sampl...standard data systems, information content analysis , work sampling and job evaluation. Con- ventional methods were found to be deficient in accounting
NASA Technical Reports Server (NTRS)
Guarneri, C. A.; Reed, A.; Renman, R. E.
1972-01-01
The manner in which current and advanced technology can be applied to develop practical solutions to existing and emerging water supply and waste disposal problems is evaluated. An overview of water resource factors as they affect new community planning, and requirements imposed on residential waste treatment systems are presented. The results of equipment surveys contain information describing: commercially available devices and appliances designed to conserve water; devices and techniques for monitoring water quality and controlling back contamination; and advanced water and waste processing equipment. System concepts are developed and compared on the basis of current and projected costs. Economic evaluations are based on community populations of from 2,000 to 250,000. The most promising system concept is defined in sufficient depth to initiate detailed design.
76 FR 11518 - QPS Evaluation Services Inc.; Recognition as an NRTL
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-02
... Council of Canada and the International Electrotechnical Commission Certification Body (IEC CB) Scheme... Equipment. UL 61010-1 Electrical Equipment for Measurement, Control, and Laboratory Use--Part 1: General...
Notification: Evaluation of Laboratory Equipment Utilization
Project #OPE-FY14-0024, April 08, 2014. The Office of Inspector General plans to begin preliminary research on equipment utilization within the U.S. Environmental Protection Agency Office of Research and Development.
Evaluating alternative service contracts for medical equipment.
De Vivo, L; Derrico, P; Tomaiuolo, D; Capussotto, C; Reali, A
2004-01-01
Managing medical equipments is a formidable task that has to be pursued maximizing the benefits within a highly regulated and cost-constrained environment. Clinical engineers are uniquely equipped to determine which policies are the most efficacious and cost effective for a health care institution to ensure that medical devices meet appropriate standards of safety, quality and performance. Part of this support is a strategy for preventive and corrective maintenance. This paper describes an alternative scheme of OEM (Original Equipment Manufacturer) service contract for medical equipment that combines manufacturers' technical support and in-house maintenance. An efficient and efficacious organization can reduce the high cost of medical equipment maintenance while raising reliability and quality. Methodology and results are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Witt, Adam M.; Hadjerioua, Boualem; Martinez, Rocio
The viability of modular pumped storage hydro (m-PSH) is examined in detail through the conceptual design, cost scoping, and economic analysis of three case studies. Modular PSH refers to both the compactness of the project design and the proposed nature of product fabrication and performance. A modular project is assumed to consist of pre-fabricated standardized components and equipment, tested and assembled into modules before arrival on site. This technology strategy could enable m-PSH projects to deploy with less substantial civil construction and equipment component costs. The concept of m-PSH is technically feasible using currently available conventional pumping and turbine equipment,more » and may offer a path to reducing the project development cycle from inception to commissioning.« less
Evaluation of fuel equipment operability of diesel locomotive engine with use of infrared receivers
NASA Astrophysics Data System (ADS)
Ovcharenko, S. M.; Balagin, O. V.; Balagin, D. V.
2018-03-01
This paper provides results of modelling the heat liberation in high-pressure pipeline of fuel equipment of diesel locomotive engines. Functional relationships between the technical state of fuel equipment and temperature of the outer surface of the high-pressure fuel pipeline are presented using the example of diesel locomotive engine 1-PD4D. The paper shows results of operational tests of the developed method for control of fuel equipment operability of diesel locomotive.
Evaluation of the automated distress survey equipment : final report, September 2009.
DOT National Transportation Integrated Search
2009-09-01
This research: : Illustrated the abilities and limitations of the Automated Distress Survey : Equipment and Software to collect, characterize, and analyze pavement : cracking distresses under different lighting conditions. : Assessed the NJDO...
Code of Federal Regulations, 2014 CFR
2014-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES... and Certification Center, 765 Technology Drive, Triadelphia, WV 26059. (b) Proposed modifications...
A simple solution for improving reliability of cardiac arrest equipment provision in hospital.
Davies, Michelle; Couper, Keith; Bradley, Julie; Baker, Annalie; Husselbee, Natalie; Woolley, Sarah; Davies, Robin P; Perkins, Gavin D
2014-11-01
Effective and safe cardiac arrest care in the hospital setting is reliant on the immediate availability of emergency equipment. The patient safety literature highlights deficiencies in current approaches to resuscitation equipment provision, highlighting the need for innovative solutions to this problem. We conducted a before-after study at a large NHS trust to evaluate the effect of a sealed tray system and database on resuscitation equipment provision. The system was evaluated by a series of unannounced inspections to assess resuscitation trolley compliance with local policy prior to and following system implementation. The time taken to check trolleys was assessed by timing clinicians checking both types of trolley in a simulation setting. The sealed tray system was implemented in 2010, and led to a significant increase in the number of resuscitation trolleys without missing, surplus, or expired items (2009: n=1 (4.76%) vs 2011: n=37 (100%), p<0.001). It also significantly reduced the time required to check each resuscitation trolley in the simulation setting (12.86 (95% CI: 10.02-15.71) vs 3.15 (95% CI: 1.19-4.51)min, p<0.001), but had no effect on the number of resuscitation trolleys checked every day over the previous month (2009: n=8 (38.10%) vs 2011: n=11 (29.73%), p=0.514). The implementation of a sealed tray system led to a significant and sustained improvement in resuscitation equipment provision, but had no effect on resuscitation trolley checking frequency. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Wilkes, A R; Pandit, J J; O'Sullivan, E
2011-12-01
Recent guidance published by the Association of Anaesthetists of Great Britain and Ireland encourages the purchase of equipment based on evidence of safety and performance. For many years, evidence of the safety and performance of anaesthetic equipment was published by various government departments and agencies. However, these schemes were gradually eroded over time such that many devices entered the market with little or no clinical evidence of their efficacy. This recently led to the Difficult Airway Society's issuing guidance to its members on how best to select new airway devices; guidance that was based on the available evidence. This article provides a short history of the evaluation of anaesthetic equipment in the United Kingdom. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.
NASA Astrophysics Data System (ADS)
Mizukami, Masato; Makihara, Mitsuhiro
2013-07-01
Conventionally, in intelligent buildings in a metropolitan area network and in small-scale facilities in the optical access network, optical connectors are joined manually using an optical connection board and a patch panel. In this manual connection approach, mistakes occur due to discrepancies between the actual physical settings of the connections and their management because these processes are independent. Moreover, manual cross-connection is time-consuming and expensive because maintenance personnel must be dispatched to remote places to correct mistakes. We have developed a fiber-handling robot and optical connection mechanisms for automatic cross-connection of multiple optical connectors, which are the key elements of automatic optical fiber cross-connect equipment. We evaluate the performance of the equipment, such as its optical characteristics and environmental specifications. We also devise new optical connection mechanisms that enable the automated optical fiber cross-connect module to handle and connect angled physical contact (APC) optical connector plugs. We evaluate the performance of the equipment, such as its optical characteristics. The evaluation results confirm that the automated optical fiber cross-connect equipment can connect APC connectors with low loss and high return loss, indicating that the automated optical fiber cross-connect equipment is suitable for practical use in intelligent buildings and optical access networks.
Establishing native vegetation and improved invasive species control on North Carolina roadsides.
DOT National Transportation Integrated Search
2011-10-20
"Field, greenhouse, and laboratory studies were conducted to evaluate the feasibility for the use of native warm season grasses (NWSGs) on North Carolina roadsides. Location, equipment, and multiple grass species were assessed to determine the ideal ...
Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations, and operation and maintenance issues
32 CFR 37.535 - How do I value cost sharing related to real property or equipment?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 1 2010-07-01 2010-07-01 false How do I value cost sharing related to real... Evaluation Cost Sharing § 37.535 How do I value cost sharing related to real property or equipment? You rarely should accept values for cost sharing contributions of real property or equipment that are in...
Conceptual Design of Fertilizer Applicator for Oil Palm on Terrace Cultivation
NASA Astrophysics Data System (ADS)
Hermawan, W.
2018-05-01
The mechanical application of fertilizer for oil palm planted on terraces is still constrained by the narrow path which is difficult to pass by a power spreader. The objective of this research was to develop a conceptual design of fertilizer applicator for oil palm planted on terraces. The design requirements were developed based on a) terrace and track conditions, b) fertilizers and fertilization conditions, c) available prime movers, and d) user needs. Five design concepts were obtained: 1) an applicator with left and right arms to distribute the fertilizer, 2) an all-terrain vehicle equipped with a manually operated fertilizer injector, 3) an applicator equipped with a hole digger, 4) an applicator equipped with a shovel, and 5) an applicator equipped with a rotary tiller. The concepts were evaluated and compared with the current power spreader. The evaluation results showed that the applicator equipped with a rotary tiller had the most advantages on the expected criteria. The final design concept uses a 110 cm wide mini crawler tractor as the prime mover and is equipped with a hopper and a spinner disk for metering and conveying the fertilizer, and a 20 cm wide rotary tiller in the front of the machine.
Summary of the electromagnetic compatibility evaluation of the proposed satellite power system
NASA Technical Reports Server (NTRS)
Morrison, E. L., Jr.; Grant, W. B.; Davis, K. C.
1980-01-01
The effects of the proposed solar power satellite (SPS) operations on electronic equipment and systems by fundamental, harmonic, and intermodulation component emissions from the orbital station; and the fundamental, harmonic, and structural intermodulation emissions from the rectenna site were evaluated. The coupling and affects interactions affecting a wide spectrum of electronic equipment are considered. The primary EMC tasking areas are each discussed separately.
Evaluation of Equipment Vulnerability and Potential Shock Hazards. [carbon fibers
NASA Technical Reports Server (NTRS)
Taback, I.
1980-01-01
The vulnerability of electric equipment to carbon fibers released from aircraft accidents is investigated and the parameters affecting vulnerability are discussed. The shock hazard for a hypothetical set of accidents is computed.
Effective approaches to disorientation familiarization for aviation personnel.
DOT National Transportation Integrated Search
1970-11-01
Techniques are discussed for providing familiarization of aviation personnel with disorientation problems. The procedures are spelled out in detail. Methods of modifying existing equipment as well as an evaluation of available commercial equipment ar...
Evaluation of the Caravelle litter retrieval system.
DOT National Transportation Integrated Search
1988-01-01
Based on observations, the Caravelle Litter Technologies, Inc's., demonstration of its litter retrieval equipment it was concluded that use of the equipment on highways open to traffic would require extensive and expensive traffic control. The machin...
Constant Head Evaluation of Full Scale Soil Absorption Fields
NASA Astrophysics Data System (ADS)
Dix, S. P.
2001-05-01
Design loading rates for septic tank effluent in trenches of various designs with different geometry and media has been debated for decades. The role of bottom and sidewall is a hot topic with many opinion by experts in the field of agricultural and environmental engineering. Research institutions have conducted numerous studies and developed procedures for measuring both test systems and fundamental of soil hydraulics. Falling head tests have been used more recently to evaluate mature test cells and evaluate both sidewall and basal absorption, (Keys et al). The proposed paper will discuss the design and testing of a constant head permeameter. Testing this equipment and developing the test protocol followed the application of the procedure to on a number of residential systems in both sandy and clay loam soil. Results from this testing showed the relability step that must be taken to successfully use this equipment. Result of the testing show the variability and consistency of absorption, the changes in absorption when systems are flooded above their equilibrium condition and the longer-term changes that occur when trenches are rested in a warm climate. More recent application of the test procedure evaluated affects of head and increased depth sidewall on absorption rates when the effluent level in the trenches was raised. Future modification of the test equipment and procedure by integrating a data logger will permits more exact recording of dose cycles and improved estimate of soil absorption efficiency over time.
Coquart, Jérémy B; Le Rouzic, Olivier; Racil, Ghazi; Wallaert, Benoit; Grosbois, Jean-Marie
2017-01-01
Pulmonary rehabilitation (PR) is a key treatment of chronic obstructive pulmonary disease (COPD) but studies are still needed to identify the most pertinent criteria to personalize this intervention and improve its efficacy. This real-life retrospective study compared the effects of home-based PR on exercise tolerance, anxiety, depression, and health-related quality of life (HRQoL) in COPD patients, according to their medical equipment. Exercise tolerance, anxiety, depression, and HRQoL were evaluated in 109 patients equipped with long-term oxygen therapy (LTOT), 84 patients with noninvasive ventilation (NIV), 25 patients with continuous positive airway pressure (CPAP), and 80 patients with no equipment (NE), before, just after, and 6 and 12 months after PR. At baseline, the body mass index in the CPAP and NIV groups was higher ( p <0.05) than in the other two groups, and the forced expiratory volume in 1 second was lower in the LTOT and NIV groups ( p <0.001). All parameters improved after PR in the four groups ( p <0.05), but for exercise tolerance, only the 6-minute stepper test showed maintained improvement after 6 and 12 months, whereas the 10 times sit-to-stand and timed up-and-go tests were only improved just after PR. At every time point, exercise tolerance was lower in the LTOT group ( p <0.05), with a similar trend in the NIV group. Despite differences in the medical equipment to treat COPD, home-based PR showed comparable feasibility, safety, and efficacy in all equipment-based groups. Medical equipment should therefore not be a barrier to home-based PR.
NASA Technical Reports Server (NTRS)
Green, R. H.
1972-01-01
In 1969 the Jet Propulsion Laboratory undertook an investigation to determine which of its space-derived capabilities could make significant contributions to the improvement of health care delivery in the U.S. The area of planetary quarantine was identified as one of high relevance. Two studies were conducted in this connection. The first study, which could contribute to infection reduction and control, was concerned with conversion of infection implicated complex, nonheat sterilizable equipment to dry heat, sterilizable equipment by changes in design and materials of construction. The second study area related to hospital acquired infection is clean room technology. A definite investigation has been performed to demonstrate and statistically evaluate performance under controlled conditions.
NASA Astrophysics Data System (ADS)
Jin, Huang; Ling, Lin; Jun, Guo; Jianguo, Li; Yongzhong, Wang
2017-11-01
Facing the increasingly severe situation of air pollution, China are now positively promoting the evaluation of high efficiency air pollution control equipments and the research of the relative national standards. This paper showed the significance and the effect of formulating the technical requirements of high efficiency precipitator equipments for assessment national standards in power industries as well as the research thoughts and principle of these standards. It introduce the qualitative and quantitative evaluation requirements of high efficiency precipitators using in power industries and the core technical content such as testing, calculating, evaluation methods and so on. The implementation of a series of national standards is in order to lead and promote the production and application of high efficiency precipitator equipments in the field of the prevention of air pollution in national power industries.
NASA Astrophysics Data System (ADS)
Guo, Lijuan; Yan, Haijun; Gao, Wensheng; Chen, Yun; Hao, Yongqi
2018-01-01
With the development of power big data, considering the wider power system data, the appropriate large data analysis method can be used to mine the potential law and value of power big data. On the basis of considering all kinds of monitoring data and defects and fault records of main transformer, the paper integrates the power grid, equipment as well as environment data and uses SVM as the main algorithm to evaluate the risk of the main transformer. It gets and compares the evaluation results under different modes, and proves that the risk assessment algorithms and schemes have certain effectiveness. This paper provides a new idea for data fusion of smart grid, and provides a reference for further big data evaluation of power grid equipment.
Evaluation of test equipment for the detection of contamination on electronic circuits
NASA Astrophysics Data System (ADS)
Bergendahl, C. G.; Dunn, B. D.
1984-08-01
The reproducibility, sensitivity and ease of operation of test equipment for the detection of ionizable contaminants on the surface of printed circuit assemblies were assessed. The characteristics of the test equipment are described. Soldering fluxes were chosen as contaminants and were applied in controlled amounts to printed-circuit board assemblies possessing two different component populations. Results show that the relationship between equipment readings varies with flux type. Each kind of test equipment gives a good measure of board cleanliness, although reservations exist concerning the interpretation of such results. A test method for the analysis of total (organic and inorganic) halides in solder fluxes is presented.
ERIC Educational Resources Information Center
Housmam, John L.; And Others
The instructor's guide is coordinated for use with the student guide. The guide includes suggestions for teacher preparation, equipment and supply needs, suggested references, available audiovisual materials, open-ended questions for classroom discussion, educational opportunities for students, and a form for student evaluation of the study guide.…
Using Haworthia Cultured Cells as an Aid in Teaching Botany
ERIC Educational Resources Information Center
Majumdar, Shyamal K.; Castellano, John M.
1977-01-01
Callus induction from species of Haworthia can be done quickly in the laboratory with minimal equipment to study tissue dedifferentiation and cellular redifferentiation. It is shown that the cultured cell can also be used to study and evaluate the effects of various mutagens, carcinogens, and pesticides in controlled environments. (Author/MA)
Fire safety of passenger trains : phase I : material evaluation (cone calorimeter)
DOT National Transportation Integrated Search
1999-01-01
As part of the passenger equipment rulemaking required by Congress, the Federal Railroad Administration (FRA) has proposed that its existing fire safety guidelines be made mandatory. A major conclusion of a FRA-funded 1993 study by the National Insti...
Reduced order model based on principal component analysis for process simulation and optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lang, Y.; Malacina, A.; Biegler, L.
2009-01-01
It is well-known that distributed parameter computational fluid dynamics (CFD) models provide more accurate results than conventional, lumped-parameter unit operation models used in process simulation. Consequently, the use of CFD models in process/equipment co-simulation offers the potential to optimize overall plant performance with respect to complex thermal and fluid flow phenomena. Because solving CFD models is time-consuming compared to the overall process simulation, we consider the development of fast reduced order models (ROMs) based on CFD results to closely approximate the high-fidelity equipment models in the co-simulation. By considering process equipment items with complicated geometries and detailed thermodynamic property models,more » this study proposes a strategy to develop ROMs based on principal component analysis (PCA). Taking advantage of commercial process simulation and CFD software (for example, Aspen Plus and FLUENT), we are able to develop systematic CFD-based ROMs for equipment models in an efficient manner. In particular, we show that the validity of the ROM is more robust within well-sampled input domain and the CPU time is significantly reduced. Typically, it takes at most several CPU seconds to evaluate the ROM compared to several CPU hours or more to solve the CFD model. Two case studies, involving two power plant equipment examples, are described and demonstrate the benefits of using our proposed ROM methodology for process simulation and optimization.« less
Huang, J Y; Liu, C D; Zhang, W M; Fu, Y K; Ma, H Y
2018-02-20
Objective: To investigate and predict the behavioral intention and mode of the protective equipment utilization selection of the workers who used Benzene, the Theory of Planned Behavior (TPB) was applied to establish the behavioral model to enhance the theoretical foundation for long-term intervention. Methods: Questionnaires were used to survey the 707 workers, and all the behaviors of using protective equipment were investigated. Evaluate the relationships between each variable and obtain the influence affects by structural equation model. Results: The investigation showed that 38.47% of the total workers (272 cases) used whole body protection, 13.58% used partially, and 16.69% didn't use any body protection. There were significant difference between the varying degrees in the four dimensions (behavioral attitude, perceived behavior control, subjective norm, and behavioral intention) (P<0.01) . The results of structural equation model revealed that perceived behavior control was the most important influencing factor, subjective norm, positive attitude, negative attitude were the other three respects in sequence. The path co-efficient were 0.600、0.215、0.141 and 0.046 respectively. Conclusion: The study show that the theory of planned behavior can effectively explain the behavioral intention and behavior of protective equipment utilization. Therefore, combining the subjective initiative of individuals with the supervision of enterprises, In order to effectively enhance the protective equipment utilization of benzene workers.
Rail passenger equipment accidents and the evaluation of crashworthiness strategies
DOT National Transportation Integrated Search
2001-05-01
The U.S. Department of Transportation's Federal Railroad Administration's (FRA) Office of Research and Development has been conducting research into rail equipment crashworthiness. The approach taken in conducting this research has been to review rel...
Rail passenger equipment accidents and the evaluation of crashworthiness strategies
DOT National Transportation Integrated Search
2002-08-31
The U.S. Department of Transportation's Federal Railroad Administration's (FRA) Office of Research and Development has been conducting research into rail equipment crashworthiness. The approach taken in conducting this research has been to review rel...
ERIC Educational Resources Information Center
Moraes, Edgar P.; Confessor, Mario R.; Gasparotto, Luiz H. S.
2015-01-01
This article proposes an indirect method to evaluate the corrosion rate of iron nail in simulated seawater. The official procedure is based on the direct measurement of the specimen's weight loss over time; however, a highly precise scale is required and such equipment may not be easily available. On the other hand, mobile phones equipped with…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Eric; Withers, Chuck; McIlvaine, Janet
Low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. This report evaluates the performance of variable-capacity comfort systems, with a focus on inverter-driven, variable-capacity systems, as well as proposed system enhancements.
2008-06-01
Assessment of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus Spores on Indoor Surfaces Using a Hydrogen Peroxide Gas...24-25% hydrogen peroxide (CAS # 7722-84-1), and 1-1.4% acetic acid. Clorox® bleach was diluted 1/ 1 0 th with sterile distilled water. Clean Earth...Peridox TM was diluted 1/6th with sterile distilled water. The disinfectants were used within 2 hr of their preparation. 2.2 Coupon Procurement Small size
[Angiography: safety x economy].
Torres, Rogil José de Almeida; Muccioli, Cristina; Casella, Antonio Marcelo Barbante; Regonha, Eduardo; Luchini, Andréa; Weiss, Wilma; Frecceiro, Paulo Roberto
2006-01-01
To evaluate the safety, effectiveness, and cost of angiofluoresceinographic examination by using both the least amount of dye as well as digital equipment along with a laser photocopier. Prospective and comparative study carried out in a group of 70 patients, who underwent an angiographic evaluation with a conventional retinographer injecting 5 ml sodium fluorescein at 10% (control group) as well as a group of 70 patients who underwent an angiographic evaluation with a digital retinographer injecting 2 ml fluorescein at 10% (study group). Arterial pressure, heart rate and oximetry were assessed prior to and after the dye injection. Organic reactions related to the examination were reported. Photograph quality as well as cost between the two techniques were compared. Control group patients showed a greater increase in systolic and diastolic arterial pressure. Heart rate, oximetry measurement and adverse reactions did not show any significant statistical differences between both groups. As for the quality of photographs, a better performance was noticed in the control group. As for the cost, the examination carried out in the study group required lower cost and thus saved around 54.8% per examination in relation to the control group. The examination carried out with a lower dose of fluorescein using digital equipment along with a laser photocopier provided greater stability in the systolic and diastolic arterial pressure. However, it did not have any influence on heart rate, oximetry or adverse reactions such as nausea, vomiting, syncope and rashes. The quality of photographs was poor although they enabled diagnosis as well as therapy follow-up for those who carried out the examination. Moreover, economically the above procedure represented a gain of 66.26%, against 25.81% in relation to the conventional equipment.
Streicher-Porte, Martin; Marthaler, Christian; Böni, Heinz; Schluep, Mathias; Camacho, Angel; Hilty, Lorenz M
2009-08-01
With the intention of bridging the 'digital divide' many programmes have been launched to provide computers for educational institutions, ranging from refurbishing second hand computers to delivering low cost new computers. The fast and economical provision of large quantities of equipment is one of the many challenges faced by such programmes. If an increase is to be achieved in the sustainability of computer supplies for schools, not only must equipment be provided, but also suitable training and maintenance delivered. Furthermore, appropriate recycling has to be ensured, so that end-of-life equipment can be dealt with properly. This study has evaluated the suitability of three computer supply scenarios to schools in Colombia: (i) 'Colombian refurbishment', -refurbishment of computers donated in Colombia, (ii) 'Overseas refurbishment', -import of computers which were donated and refurbished abroad, and (iii) 'XO Laptop', -purchase of low cost computers manufactured in Korea. The methods applied were: Material Flow Assessment, -to assess the quantities-, Life Cycle Assessment, -to assess the environmental impacts, and the application of the Multiple Attribute Utility Theory, -to analyse, evaluate and compare different scenarios. The most sustainable solution proved to be the local refurbishment of second hand computers of Colombian origin to an appropriate technical standard. The environmental impacts of such practices need to be evaluated carefully, as second hand appliances have to be maintained, require spare parts and sometimes use more energy than newer equipment. Providing schools with second hand computers from overseas and through programmes such as 'One Laptop Per Child' has the disadvantage that the potential for social improvements - such as creation of jobs and local industry involvement - is very low.
da Luz, Maurício Antônio; Costa, Leonardo Oliveira Pena; Fuhro, Fernanda Ferreira; Manzoni, Ana Carolina Taccolini; Oliveira, Naiane Teixeira Bastos; Cabral, Cristina Maria Nunes
2014-05-01
The Pilates method has been widely used to treat patients with chronic low back pain. Pilates exercises can be performed in 2 ways: by using specific equipment or without it (also known as mat Pilates). There are no studies, however, that have compared the effectiveness of mat Pilates with that of equipment-based Pilates. The aim of this study was to compare the effectiveness of mat Pilates and equipment-based Pilates in patients with chronic nonspecific low back pain. A 2-arm randomized controlled trial with a blinded assessor was conducted. The study was conducted at a private physical therapy clinic in Brazil. Eighty-six patients with chronic nonspecific low back pain participated. The patients were randomly allocated to 1 of 2 groups: a mat Pilates group (n=43) and an equipment-based Pilates group (n=43). The participants in both groups attended 12 Pilates sessions over a period of 6 weeks. The primary outcomes were pain intensity and disability. The secondary outcomes were global perceived effect, patient's specific disability, and kinesiophobia. A blinded assessor evaluated the outcomes at baseline and 6 weeks and 6 months after randomization. After 6 months, there was a statistically significant difference for disability (mean difference=3.0 points, 95% confidence interval [CI]=0.6 to 5.4), specific disability (mean difference=-1.1 points, 95% CI=-2.0 to -0.1), and kinesiophobia (mean difference=4.9 points, 95% CI=1.6 to 8.2) in favor of equipment-based Pilates. No differences were found for the remaining outcomes. Equipment-based Pilates was superior to mat Pilates in the 6-month follow-up for the outcomes of disability and kinesiophobia. These benefits were not observed for pain intensity and global perceived effect in patients with chronic nonspecific low back pain.
NASA Astrophysics Data System (ADS)
Xiaoxin, Zhang; Jin, Huang; Ling, Lin; Yan, Li
2018-05-01
According to the undeveloped evaluation method for the operational performance of the municipal wastewater treatment plants, this paper analyzes the policies related to sewage treatment industry based on the investigation of the municipal wastewater treatment plants. The applicable evaluation method for the operational performance was proposed from environmental protection performance, resources and energy consumption, technical and economic performance, production management and main equipment, providing a reliable basis for scientific evaluation of the operation as well as improving the operational performance of municipal wastewater treatment plant.
Orbiter CIU/IUS communications hardware evaluation
NASA Technical Reports Server (NTRS)
Huth, G. K.
1979-01-01
The DOD and NASA inertial upper stage communication system design, hardware specifications and interfaces were analyzed to determine their compatibility with the Orbiter payload communications equipment (Payload Interrogator, Payload Signal Processors, Communications Interface Unit, and the Orbiter operational communications equipment (the S-Band and Ku-band systems). Topics covered include (1) IUS/shuttle Orbiter communications interface definition; (2) Orbiter avionics equipment serving the IUS; (3) IUS communication equipment; (4) IUS/shuttle Orbiter RF links; (5) STDN/TDRS S-band related activities; and (6) communication interface unit/Orbiter interface issues. A test requirement plan overview is included.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Romberger, Jeff
The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rawls, G.
ASME is evaluating the use of additive manufacturing (AM) for the construction of pressure equipment. The information in this report assesses available AM technologies for direct metal fabrication of pressure equipment. Background information is included in the report to provide context for those not experienced in AM technology. Only commercially available technologies for direct metal fabrication are addressed in the report because these AM methods are the only viable approaches for the construction of pressure equipment. Metal AM technologies can produce near-net shape parts by using multiple layers of material from a three dimensional (3D) design model of the geometry.more » Additive manufacturing of metal components was developed from polymer based rapid prototyping or 3D printing. At the current maturity level, AM application for pressure equipment has the potential to reduce delivery times and costs for complex shapes. AM will also lead to a reduction in the use of high cost materials, since parts can be created with corrosion resistant layers of high alloy material and structural layers of lower cost materials.« less
Patiño-Marín, N; Loyola-Rodríguez, J P; Tovar-Reyes, L F
2001-01-01
To assess the utilization of sterilizing equipment used by dentists, and verification of sterilization using biological indicators. A cross-sectional study was conducted in 1999-2000, among 130 (65%) dentists having sterilizing equipment, at Facultad de Estomatología, Universidad Autónoma de San Luis Potosí and Colegio Dental Potosino. Biological indicators for sterilization containing Bacillus subtilis and Bacillus stearothermophilus were used. Thirty autoclaves and 100 dry-heat sterilizers were evaluated: 23 (17.7%) of them showed bacterial growth. Twenty-one (16.1%) dentists already were using biological indicators to verify their sterilizing equipment. Both sterilization methods were found to allow bacterial growth with similar frequencies (p = > 0.66). Few dentists verify the quality of sterilization process through biological indicators; bacterial growth and failure of sterilization were evidenced.
McCue, Michael J
2011-01-01
Prior literature provides only a descriptive view of the types and numbers of capital expenditures made by hospitals. This study conducted an empirical analysis to assess simultaneously what market, organizational, and financial factors relate to the number of capital projects as well as the specific types: medical equipment, expansion, and maintenance projects. Sampling California hospital capital expenditure data from 2002 to 2007, this study aggregated the number of capital projects by each type of capital investment decision: medical equipment, expansion, and maintenance/renovation per hospital. Using ordinary least squares regression, this study evaluated the association of these factors with these types of capital investment projects. This study found that hospitals capturing a greater share of the market, maintaining high levels of liquidity, and operating with more than 350 beds invested in a greater number of capital projects per hospital as well as medical equipment and expansionary projects per hospital. Within the state of California, the demand for health care services within a hospital market as well as cash and investment reserves were key drivers in the hospital CEOs and boards' decision to increase their capital purchases. The types of purchases included capital outlays related to medical equipment, such as CT scanners, MRIs, and surgical systems, and revenue-generating expansionary projects, such as new bed towers, hospitals wings, operating and emergency rooms, and replacement hospitals from 2002 to 2007.
Is LabTutor a helpful component of the blended learning approach to biosciences?
Swift, Amelia; Efstathiou, Nikolaos; Lameu, Paula
2016-09-01
To evaluate the use of LabTutor (a physiological data capture and e-learning package) in bioscience education for student nurses. Knowledge of biosciences is important for nurses the world over, who have to monitor and assess their patient's clinical condition, and interpret that information to determine the most appropriate course of action. Nursing students have long been known to find acquiring useable bioscience knowledge challenging. Blended learning strategies are common in bioscience teaching to address the difficulties students have. Student nurses have a preference for hands-on learning, small group sessions and are helped by close juxtaposition of theory and practice. An evaluation of a new teaching method using in-classroom voluntary questionnaire. A structured survey instrument including statements and visual analogue response format and open questions was given to students who participated in Labtutor sessions. The students provided feedback in about the equipment, the learning and the session itself. First year (n = 93) and third year (n = 36) students completed the evaluation forms. The majority of students were confident about the equipment and using it to learn although a few felt anxious about computer-based learning. They all found the equipment helpful as part of their bioscience education and they all enjoyed the sessions. This equipment provides a helpful way to encourage guided independent learning through practice and discovery and because each session is case study based and the relationship of the data to the patient is made clear. Our students helped to evaluate our initial use of LabTutor and found the sessions enjoyable and helpful. LabTutor provides an effective learning tool as part of a blended learning strategy for biosciences teaching. Improving bioscience knowledge will lead to a greater understanding of pathophysiology, treatments and interventions and monitoring. © 2016 John Wiley & Sons Ltd.
Evaluating selection and efficacy of pressure-relieving equipment.
Chaloner, Donna; Stevens, Jenny
2003-06-01
The drive towards evidence-based practice has highlighted the lack of randomized controlled trials that compare interventions such as pressure-relieving medical devices. This may influence practitioners, particularly purchasing practitioners, to consider other types of evidence when appraising literature to determine clinical practice and support recommendations and local guidelines. This article will illustrate the development of an audit tool used to evaluate nurses' knowledge and skills in patient assessment, selection and installation of appropriate pressure-relieving equipment. The tool also assists in assessing clinical effectiveness and user satisfaction of equipment. This article focuses on a small audit of the Karomed Ltd Transair 1500 (also known as the 3-Comm) mattress replacement system.
Citizen CATE: Evaluating Outcomes of a Solar Eclipse Citizen Science Project
NASA Astrophysics Data System (ADS)
Penn, M. J.; Haden, C.
2017-12-01
On August 21, 2017, a total solar eclipse will be visible along a path of totality from Oregon to South Carolina. The Citizen Continental-America Telescopic Eclipse Experiment (CATE) will use scientists, students and volunteers to take images of the solar corona using 68 identical telescopes, software and instrument packages along the 2,500-mile path of totality. CATE partners include National Solar Observatory scientists, university faculty and students, high school students, and professional and amateur astronomers. NASA funded CATE educational components including training undergraduates and volunteers on solar imaging software and equipment. The National Science Foundation and corporations including DayStar, MathWorks, Celestron and ColorMaker funded equipment. Undergraduates participated in summer research experiences to build their capacity for gathering eclipse data, and subsequently trained volunteers across the U.S. Aligned to NASA education goals, CATE goals range from providing an authentic research experience for students and lifelong learners, to making state-of-the-art solar coronal observations, to increasing scientific literacy of the public. While project investigators are examining the wealth of scientific data that will come from CATE, evaluators are examining impacts on participants. Through mixed methods, evaluators are examining outcomes related to changes in volunteers' knowledge, skills and attitudes. Additionally, the study will examine how citizen science astronomy using CATE equipment will continue after the eclipse to sustain project impacts. Preliminary findings for undergraduates indicate that they are gaining knowledge and skills related to studying solar coronal phenomena, conducting rigorous scientific research, and interfacing with the public to conduct outreach. Preliminary findings for citizen scientists indicate a high level of engagement in the research, and that they are gaining new knowledge and skills related to solar science and eclipses. Volunteers also reported learning a great deal about safety while observing the Sun. This evaluation study will add to the body of knowledge about the effectiveness and utility of citizen science programs. Findings will be updated with data collected during and immediately after the eclipse events.
Dąbrowska, M; Mielcarek, A; Nowak, I
2018-04-29
Evaluation of skin condition on the basis of parametrization and objective measurements of the parameters has become obligatory. The aim of this study was to assess sex-related changes in skin topography and structure using the skin testing equipment. The study was carried out on the group of 40 volunteers (20 females and 20 males) of the mean age 24 ± 3 years. The skin parameters were measured using 3 devices: Visioscan ® VC 98 (skin topography), Visioline ® VL 650 (skin macro relief) and Ultrascan UC22 (ultrasound imaging of the skin). All measurements were performed on the inner part of the left forearm. The skin parameters measured revealed significant differences in skin surface and structure between females and males. The skin of all women subjects was more homogenous in its structure with the presence of more abundant superficial skin lines and wrinkles in comparison to male skin. The higher number of skin furrows in the skin of women is in agreement with literature reports claiming that men's skin has lower number of wrinkles which are deeper and more pronounced. Ultrasound imaging of the skin indicated greater thickness and lower density of the dermis of men subjects compared to those of females. Non-invasive methods of skin testing using new and advanced equipment have provided a possibility of objective parametrization and evaluation of sex-related changes in skin topography and structure. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
48 CFR 252.239-7018 - Supply chain risk.
Code of Federal Regulations, 2014 CFR
2014-10-01
... subsystem(s) of equipment, that is used in the automatic acquisition, storage, analysis, evaluation..., ancillary equipment (including imaging peripherals, input, output, and storage devices necessary for... of a computer, software, firmware and similar procedures, services (including support services), and...
Assessment of Automatic Fare Collection Equipment at Three European Transit Properties
DOT National Transportation Integrated Search
1982-12-01
This report is an assessment of automatic fare collection (AFC) equipment performance conducted at three European properties in accordance with procedures defined in the Property Evaluation Plan (PEP) developed by Input Output Computer Services, Inc....
Code of Federal Regulations, 2013 CFR
2013-07-01
... Resources BUREAU OF OCEAN ENERGY MANAGEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OPERATIONS IN THE OUTER... detailed Mining Plan than is obtainable under an approved Delineation Plan, to prepare feasibility studies, to carry out a pilot program to evaluate processing techniques or technology or mining equipment, or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Resources BUREAU OF OCEAN ENERGY MANAGEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OPERATIONS IN THE OUTER... detailed Mining Plan than is obtainable under an approved Delineation Plan, to prepare feasibility studies, to carry out a pilot program to evaluate processing techniques or technology or mining equipment, or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Resources BUREAU OF OCEAN ENERGY MANAGEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OPERATIONS IN THE OUTER... detailed Mining Plan than is obtainable under an approved Delineation Plan, to prepare feasibility studies, to carry out a pilot program to evaluate processing techniques or technology or mining equipment, or...
29 CFR 1960.56 - Training of safety and health specialists.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., laboratory experiences, field study, and other formal learning experiences to prepare them to perform the... program development and implementation, as well as hazard recognition, evaluation and control, equipment... tasks. (b) Each agency shall implement career development programs for their occupational safety and...
MEASUREMENT OF INDOOR AIR EMISSIONS FROM DRY-PROCESS PHOTOCOPY MACHINES
The article provides background information on indoor air emissions from office equipment, with emphasis on dry-process photocopy machines. The test method is described in detail along with results of a study to evaluate the test method using four dry-process photocopy machines. ...
Solair heater program: solair applications study. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1977-12-01
General Electric has designed and tested a low-cost solar system using a vacuum tube solar air heater under ERDA Contract E(11-1)-2705. This contract extension has been provided to evaluate various applications of this solar collector. The evaluation identified attractive applications, evaluated corresponding control procedures, estimated system performance, compared economically insolation and insulation, and evaluated the repackaging of off-the-shelf equipment for improved cost effectiveness. The results of this study prompted General Electric's marketing group to do a detailed commercialization study of a residential domestic water heating system using the Solair concept which has been selected as the most attractive application. Othermore » attractive applications are space/domestic water heating and a heat pump assisted solar system/domestic water heating where the heat pump and the solar system function in parallel. A prime advantage of heated air solar systems over liquid systems is cost and longer life which results in higher BTU's/dollar. Other air system advantages are no liquid leakage problems, no toxicity of freezing problems, and less complicated equipment. A hybrid solar system has been identified that can improve the market penetration of solar energy. This system would use the existing mass of the house for energy storage thereby reducing solar cost and complexity. Adequate performance can be obtained with house temperature swings comparable to those used in nighttime setback of the thermostat. Details of this system are provided.« less
A RANDOM-SCAN DISPLAY OF PREDICTED SATELLITE POSITIONS.
With the completion of the NRL evaluation of the experimental model of the Satellite Position Prediction and Display equipment ( SPAD ), efforts were...directed toward the design of an operational version of SPAD . Possible design and equipment configurations were proposed which would lead to a...substantial savings in cost and reduced equipment complexity. These designs involve the displaying of the SPAD information by means of a random scanning of
A life sciences Spacelab mission simulation
NASA Technical Reports Server (NTRS)
Mason, J. A.; Musgrave, F. S.; Morrison, D. R.
1977-01-01
The paper describes the purposes of a seven-day simulated life-sciences mission conducted in a Spacelab simulator. A major objective was the evaluation of in-orbit Spacelab operations and those mission control support functions which will be required from the Payload Operations Center. Tested equipment and procedures included experiment racks, common operational research equipment, commercial off-the-shelf equipment, experiment hardware interfaces with Spacelab, experiment data handling concepts, and Spacelab trash management.
Gullà, F; Zambelli, P; Bergamaschi, A; Piccoli, B
2007-01-01
The aim of this study is the objective evaluation of the visual effort in 6 public traffic controllers (4 male, 2 female, mean age 29,6), by means of electronic equipment. The electronic equipment quantify the observation distance and the observation time for each controller's occupational visual field. The quantification of these parameters is obtained by the emission of ultrasound at 40 KHz from an emission sensor (placed by the VDT screen) and the ultrasound reception by means of a receiving sensor (placed on the operator's head). The travelling time of the ultrasound (US), as the air speed is known and costant (about 340 m/s), it is used to calculate the distance between the emitting and the receiving sensor. The results show that the visual acuity required is of average level, while accommodation's and convergence's effort vary from average to intense (depending on the visual characteristics of the operator considered), ranging from 26,41 and 43,92% of accommodation and convergence available in each operator. The time actually spent in "near observation within the c.v.p." (Tscr) was maintained in a range from 2h 54' and 4h 05'.
Metrological reliability of optical coherence tomography in biomedical applications
NASA Astrophysics Data System (ADS)
Goloni, C. M.; Temporão, G. P.; Monteiro, E. C.
2013-09-01
Optical coherence tomography (OCT) has been proving to be an efficient diagnostics technique for imaging in vivo tissues, an optical biopsy with important perspectives as a diagnostic tool for quantitative characterization of tissue structures. Despite its established clinical use, there is no international standard to address the specific requirements for basic safety and essential performance of OCT devices for biomedical imaging. The present work studies the parameters necessary for conformity assessment of optoelectronics equipment used in biomedical applications like Laser, Intense Pulsed Light (IPL), and OCT, targeting to identify the potential requirements to be considered in the case of a future development of a particular standard for OCT equipment. In addition to some of the particular requirements standards for laser and IPL, also applicable for metrological reliability analysis of OCT equipment, specific parameters for OCT's evaluation have been identified, considering its biomedical application. For each parameter identified, its information on the accompanying documents and/or its measurement has been recommended. Among the parameters for which the measurement requirement was recommended, including the uncertainty evaluation, the following are highlighted: optical radiation output, axial and transverse resolution, pulse duration and interval, and beam divergence.
Anesthesia equipment malfunction: origins and clinical recognition.
McIntyre, J. W.
1979-01-01
Equipment malfunction is a problem of particular importance during anesthesia and resuscitation. A review of published reports shows that the most common clinical events involve endotracheal tubes, the inspired oxygen concentration, the volume of inspired anesthetic vapours and gases, and pressures in the breathing or ventilation system. It is concluded that protection of a patient from equipment malfunction depends on: (a) appropriate application of standards set by a national standards association; (b) careful evaluation of equipment prior to purchase; (c) comprehension of equipment function by the user; (d) conscientious routine servicing of all systems concerned with anesthesia and resuscitation, and checking after service and before clinical use; (e) preanesthesia testing of equipment, including the use of an oxygen analyser in the breathing circuit; (f) early inclusion of equipment malfunction in the differential diagnosis of events during anesthesia; and (g) rapid action that cannot present a new hazard to the patient to correct the results of apparatus malfunction. PMID:436069
Nodes packaging option for Space Station application
NASA Technical Reports Server (NTRS)
So, Kenneth T.; Hall, John B., Jr.
1988-01-01
Space Station nodes packaging analyses are presented relative to moving environmental control and life support system (ECLSS) equipment from the habitability (HAB) module to node 4, in order to provide more living space and privacy for the crew, remove inherently noisy equipment from the crew quarter, retain crew waste collection and processing equipment in one location, and keep objectionable odor away from the living quarters. In addition, options for moving external electronic equipment from the Space Station truss to pressurized node 3 were evaluated in order to reduce the crew extravehicular-activity time required to install and maintain the equipment. Node size considered in this analysis is 3.66 m in diameter and 5.38 m long. The analysis shows that significant external electronic equipment could be relocated from the Space Station truss structure to node 3, and nonlife critical ECLSS HAB module equipment could be moved to node 4.
The Thermal Evaluation of Air-Cooled Electronic Equipment
1952-09-01
of Unit with Case-Envelope Heat Exchanger 233 VII-7 Storking Plot for Evaluation of Case Heat Transfer of Unit with Integrated or Separate... wing . 1. Case Cooled by Free Convection and Radiation Equipment of this type which depends on the natural heat dissipative capacity of the outer...described application, a tightly-fitting spring- clip is placed around the component, such as a tube, with the two thermocouple lead wires spot-welded
Study of space shuttle EVA/IVA support requirements. Volume 1: Technical summary report
NASA Technical Reports Server (NTRS)
Copeland, R. J.; Wood, P. W., Jr.; Cox, R. L.
1973-01-01
Results are summarized which were obtained for equipment requirements for the space shuttle EVA/IVA pressure suit, life support system, mobility aids, vehicle support provisions, and energy 4 support. An initial study of tasks, guidelines, and constraints and a special task on the impact of a 10 psia orbiter cabin atmosphere are included. Supporting studies not related exclusively to any one group of equipment requirements are also summarized. Representative EVA/IVA task scenarios were defined based on an evaluation of missions and payloads. Analysis of the scenarios resulted in a total of 788 EVA/IVA's in the 1979-1990 time frame, for an average of 1.3 per shuttle flight. Duration was estimated to be under 4 hours on 98% of the EVA/IVA's, and distance from the airlock was determined to be 70 feet or less 96% of the time. Payload water vapor sensitivity was estimated to be significant on 9%-17% of the flights. Further analysis of the scenarios was carried out to determine specific equipment characteristics, such as suit cycle and mobility requirements.
Cheng, F T; Yang, H C; Luo, T L; Feng, C; Jeng, M
2000-01-01
Equipment Managers (EMs) play a major role in a Manufacturing Execution System (MES). They serve as the communication bridge between the components of an MES and the equipment. The purpose of this paper is to propose a novel methodology for developing analytical and simulation models for the EM such that the validity and performance of the EM can be evaluated. Domain knowledge and requirements are collected from a real semiconductor packaging factory. By using IDEFO and state diagrams, a static functional model and a dynamic state model of the EM are built. Next, these two models are translated into a Petri net model. This allows qualitative and quantitative analyses of the system. The EM net model is then expanded into the MES net model. Therefore, the performance of an EM in the MES environment can be evaluated. These evaluation results are good references for design and decision making.
Homeland Security and Defense Applications
None
2018-01-16
Homeland Security and Defense Applications personnel are the best in the world at detecting and locating dirty bombs, loose nukes, and other radiological sources. The site trains the Nation's emergency responders, who would be among the first to confront a radiological or nuclear emergency. Homeland Security and Defense Applications highly training personnel, characterize the threat environment, produce specialized radiological nuclear detection equipment, train personnel on the equipment and its uses, test and evaluate the equipment, and develop different kinds of high-tech equipment to defeat terrorists. In New York City for example, NNSS scientists assisted in characterizing the radiological nuclear environment after 9/11, and produced specialized radiological nuclear equipment to assist local officials in their Homeland Security efforts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Homeland Security and Defense Applications personnel are the best in the world at detecting and locating dirty bombs, loose nukes, and other radiological sources. The site trains the Nation's emergency responders, who would be among the first to confront a radiological or nuclear emergency. Homeland Security and Defense Applications highly training personnel, characterize the threat environment, produce specialized radiological nuclear detection equipment, train personnel on the equipment and its uses, test and evaluate the equipment, and develop different kinds of high-tech equipment to defeat terrorists. In New York City for example, NNSS scientists assisted in characterizing the radiological nuclear environmentmore » after 9/11, and produced specialized radiological nuclear equipment to assist local officials in their Homeland Security efforts.« less
The placement of equipment in the Space Station Freedom using constraint based reasoning
NASA Technical Reports Server (NTRS)
Tanner, Steve; Fennel, Randy
1991-01-01
This paper describes the Rack Equipment Placement and Optimization System. The primary objective of this system is to assist engineers with the placement of equipment into the racks of the modules of Space Station Freedom. It accomplishes this by showing a user where equipment placement is possible and by generating potential layouts. The system uses an explicit representation of integration constraints to search for potential solutions for individual rack equipment items. A simulated annealing process is being evaluated for total solution generation as well. Versions of this system are in use now and are assisting with the development of the Space Station Freedom at the Marshall Space Flight Center in Huntsville, Alabama.
Bazant, Eva; Sarkar, Supriya; Banda, Joseph; Kanjipite, Webby; Reinhardt, Stephanie; Shasulwe, Hildah; Mulilo, Joyce Monica Chongo; Kim, Young Mi
2014-12-20
Human resource shortages and reforms in HIV-related care make it challenging for frontline health care providers in southern Africa to deliver high-quality services. At health facilities of the Zambian Defence Forces, a performance and quality improvement approach was implemented to improve HIV-related care and was evaluated in 2010/2011. Changes in providers' work environment and perceived quality of HIV-related care were assessed to complement data of provider performance. The intervention involved on-site training, supportive supervision, and action planning focusing on detailed service delivery standards. The quasi-experimental evaluation collected pre- and post-intervention data from eight intervention and comparison facilities matched on defence force branch and baseline client volume. Overall, 101 providers responded to a 24-item questionnaire on the work environment, covering topics of drugs, supplies, and equipment; training, feedback, and supervision; compensation; staffing; safety; fulfilment; and HIV services quality. In bivariate analysis and multivariate analyses, we assessed changes within each study group and between the two groups. In the bivariate analysis, the intervention group providers reported improvements in the work environment on adequacy of equipment, feeling safe from harm, confidence in clinical skills, and reduced isolation, while the comparison group reported worsening of the work environment on supplies, training, safety, and departmental morale.In the multivariate analysis, the intervention group's improvement and the comparison group's decline were significant on perceived adequacy of drugs, supplies, and equipment; constructive feedback received from supervisor and co-workers; and feeling safe from physical harm (all P <0.01, except P <0.04 for equipment). Further, the item "provider lacks confidence in some clinical skills" declined in the intervention group but increased in the comparison group (P = -0.005). In multivariate analysis, changes in perceived quality of HIV care did not differ between study groups. Provider perceptions were congruent with observations of preparing drugs, supplies, equipment, and in service delivery of prevention of mother-to-child transmission of HIV and antiretroviral therapy follow-up care. The performance and quality improvement intervention implemented at Zambian Defence Forces' health facilities was associated with improvements in providers' perceptions of work environment consistent with the intervention's focus on commodities, skills acquisition, and receipt of constructive feedback.
A method for economic evaluation of redundancy levels for aerospace systems
NASA Technical Reports Server (NTRS)
Hodge, P. W.; Frumkin, B.
1973-01-01
Principle comprises primary cost impacts, such as operational delays, reflown missions due to aborts, procurement of equipment, and vehicle expansion to accommodate additional equipment. Economics are estimated by criterion which is relatively insensitive to impertinent cost factors.
Evaluation of IMS - Swedish Laser road tester : final report.
DOT National Transportation Integrated Search
1990-09-01
A test of the IMS - Swedish Laser road tester was conducted in September 1988. The vehicle mounted laser equipment was used to survey pavement conditions on sections of Oregon's Interstate and non-interstate highway system. : The IMS laser equipment ...
Evaluation of Occupant Volume Strength in Conventional Passenger Railroad Equipment
DOT National Transportation Integrated Search
2008-09-24
To ensure a level of occupant volume protection, passenger : railway equipment operating on mainline railroads in the : United States must be designed to resist an 800,000-lb : compressive load applied statically along the line of draft. An : alterna...
Design of Alarm Sound of Home Care Equipment Based on Age-related Auditory Sense
NASA Astrophysics Data System (ADS)
Shibano, Jun-Ichi; Tadano, Shigeru; Kaneko, Hirotaka
A wide variety of home care equipment has been developed to support the independent lifestyle and care taking of elderly persons. Almost all of the equipment has an alarm designed to alert a care person or to sound a warning in case of an emergency. Due to the fact that aging human beings' senses physiologically, weaken and deteriorate, each alarm's sound must be designed to account for the full range of elderly person's hearing loss. Since the alarms are usually heard indoors, it is also necessary to evaluate the relationship between the basic characteristics of the sounds and living area's layout. In this study, we investigated the sounds of various alarms of the home care equipment based on both the age-related hearing characteristics of elderly persons and the propagation property of the sounds indoors. As a result, it was determined that the hearing characteristics of elderly persons are attuned to sounds which have a frequency from 700Hz to 1kHz, and it was learned that the indoor absorption ratio of sound is smallest when the frequency is 1kHz. Therefore, a frequency of 1kHz is good for the alarm sound of home care equipment. A flow chart to design the alarm sound of home care equipment was proposed, taking into account the extent of age-related auditory sense deterioration.
Ramirez, Marizen; Bedford, Ronald; Wu, Hongqian; Harland, Karisa; Cavanaugh, Joseph E; Peek-Asa, Corinne
2016-09-01
To evaluate the effectiveness of roadway policies for lighting and marking of farm equipment in reducing crashes in Illinois, Iowa, Kansas, Minnesota, Missouri, Nebraska, North Dakota, South Dakota and Wisconsin. In this ecological study, state policies on lighting and marking of farm equipment were scored for compliance with standards of the American Society of Agricultural and Biological Engineers (ASABE). Using generalized estimating equations negative binomial models, we estimated the relationships between lighting and marking scores, and farm equipment crash rates, per 100 000 farm operations. A total of 7083 crashes involving farm equipment was reported from 2005 to 2010 in the Upper Midwest and Great Plains. As the state lighting and marking score increased by 5 units, crash rates reduced by 17% (rate ratio=0.83; 95% CI 0.78 to 0.88). Lighting-only (rate ratio=0.48; 95% CI 0.45 to 0.51) and marking-only policies (rate ratio=0.89; 95% CI 0.83 to 0.96) were each associated with reduced crash rates. Aligning lighting and marking policies with ASABE standards may effectively reduce crash rates involving farm equipment. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Walker, Susanna T.; Brett, Stephen J.; McKay, Anthony; Aggarwal, Rajesh; Vincent, Charles
2012-01-01
Background and aim Inadequately designed equipment has been implicated in poor efficiency and critical incidents associated with resuscitation. A novel resuscitation trolley (Resus:Station) was designed and evaluated for impact on team efficiency, user opinion, and teamwork, compared with the standard trolley, in simulated cardiac arrest scenarios. Methods Fifteen experienced cardiac arrest teams were recruited (45 participants). Teams performed recorded resuscitation simulations using new and conventional trolleys, with order of use randomised. After each simulation, efficiency (“time to drugs”, un-locatable equipment, unnecessary drawer opening) and team performance (OSCAR) were assessed from the video recordings and participants were asked to complete questionnaires scoring various aspects of the trolley on a Likert scale. Results Time to locate the drugs was significantly faster (p = 0.001) when using the Resus:Station (mean 5.19 s (SD 3.34)) than when using the standard trolley (26.81 s (SD16.05)). There were no reports of missing equipment when using the Resus:Station. However, during four of the fifteen study sessions using the standard trolley participants were unable to find equipment, with an average of 6.75 unnecessary drawer openings per simulation. User feedback results clearly indicated a highly significant preference for the newly designed Resus:Station for all aspects. Teams performed equally well for all dimensions of team performance using both trolleys, despite it being their first exposure to the Resus:Station. Conclusion We conclude that in this simulated environment, the new design of trolley is safe to use, and has the potential to improve efficiency at a resuscitation attempt. PMID:22796405
NASA Astrophysics Data System (ADS)
Murata, C. H.; Fernandes, D. C.; Lavínia, N. C.; Caldas, L. V. E.; Pires, S. R.; Medeiros, R. B.
2014-02-01
The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered a multifunctional instrument that can appropriately evaluate the performance of radiological equipment.
NASA Technical Reports Server (NTRS)
Estes, Howard; Liggin, Karl; Crawford, Kevin; Humphries, Rick (Technical Monitor)
2001-01-01
NASA/Marshall Space Flight Center (MSFC) is continually looking for ways to reduce the costs and schedule and minimize the technical risks during the development of microgravity programs. One of the more prominent ways to minimize the cost and schedule is to use off-the-shelf hardware (OTS). However, the use of OTS often increases the risk. This paper addresses relevant factors considered during the selection and utilization of commercial off-the-shelf (COTS) flight computer processing equipment for the control of space station microgravity experiments. The paper will also discuss how to minimize the technical risks when using COTS processing hardware. Two microgravity experiments for which the COTS processing equipment is being evaluated for are the Equiaxed Dendritic Solidification Experiment (EDSE) and the Self-diffusion in Liquid Elements (SDLE) experiment. Since MSFC is the lead center for Microgravity research, EDSE and SDLE processor selection will be closely watched by other experiments that are being designed to meet payload carrier requirements. This includes the payload carriers planned for the International Space Station (ISS). The purpose of EDSE is to continue to investigate microstructural evolution of, and thermal interactions between multiple dendrites growing under diffusion controlled conditions. The purpose of SDLE is to determine accurate self-diffusivity data as a function of temperature for liquid elements selected as representative of class-like structures. In 1999 MSFC initiated a Center Director's Discretionary Fund (CDDF) effort to investigate and determine the optimal commercial data bus architecture that could lead to faster, better, and lower cost data acquisition systems for the control of microgravity experiments. As part of this effort various commercial data acquisition systems were acquired and evaluated. This included equipment with various form factors, (3U, 6U, others) and equipment that utilized various bus structures, (VME, PC104, STD bus). This evaluation of hardware was performed in conjunction with a trade study that considered over twenty (20) different factors relevant to the selection of an optimum design approach. These factors included; safety, sizing and timing, radiation hardness and single event upset, power consumption, heat dissipation, size and volume, expected service life, maintainability, heritage, operating systems, requirements for software reuse, availability of compatible interface boards, relative cost, schedule, reliability, EMI/EMC factors, "hot swap" capability, standards for conduction cooling, I/O capabilities, unique carrier requirements and operating system considerations. The approach to evaluate Safety as part of this study included a review of the Preliminary Hazard Analysis (PHA) for each of the experiment designs and a determination of how each hazard could be addressed and eliminated when different processors were selected. This included evaluating various design approaches and trade-offs between fault tolerant designs and fail-safe designs in accordance with NSTS 1700.7B. This will include the results of radiation testing where available. Various operating systems, such as VxWorks, Linux, QNX, and Embedded NT are evaluated and the advantages and disadvantages of their utilization are also addressed. Design implementation strategies for the various operating systems are considered and discussed. This paper presents the results and recommendations from this trade study. Preliminary conclusions from this study are that safety concerns from lack or radiation testing on COTS equipment can be addressed by additional testing and design considerations, the PC104 bus provided adequate I/O for the SDLE and EDSE microgravity experiments, and PC104 bus components offered significant advantages over VME and cPCI for weight and space reductions.
Effects of Psychoeducation for Offenders in a Community Correctional Facility
ERIC Educational Resources Information Center
Liau, Albert K.; Shively, Randy; Horn, Mary; Landau, Jennifer; Barriga, Alvaro; Gibbs, John C.
2004-01-01
The present study provided a randomized outcome evaluation of the psychoeducational component of the EQUIP program. The psychoeducational curriculum was implemented in a community correctional facility for adult felony offenders. The psychoeducational curriculum is designed to remedy offenders' delays in moral judgment maturity, social cognitive…
A Critical Review of Videoconferencing Software to Support School Consultation
ERIC Educational Resources Information Center
Fischer, Aaron J.; Schultz, Brandon K.; Collier-Meek, Melissa A.; Zoder-Martell, Kimberly A.; Erchul, William P.
2018-01-01
With recent advances in technology, several viable options now exist for school consultants to communicate with teachers via synchronous online videoconferencing (VC) without the need for specialized equipment. Unfortunately, few studies have evaluated the effectiveness of school consultation through VC, so practitioners are provided little…
DOT National Transportation Integrated Search
1983-07-01
A study was conducted to determine the degree of respiratory and visual protection given to the female crewmember by various crew oxygen mask/goggle combinations. The acceptance criteria for the mask/goggle combinations were for 10 of 12 test subject...
Use of NDT equipment for construction quality control of hot mix asphalt pavements
DOT National Transportation Integrated Search
2006-08-01
The focus of the study has been to evaluate the utility of seismic methods in the quality management of the hot mix asphalt layers. Procedures are presented to measure the target field moduli of hot mix asphalt (HMA) with laboratory seismic methods, ...
Simulation Environment Synchronizing Real Equipment for Manufacturing Cell
NASA Astrophysics Data System (ADS)
Inukai, Toshihiro; Hibino, Hironori; Fukuda, Yoshiro
Recently, manufacturing industries face various problems such as shorter product life cycle, more diversified customer needs. In this situation, it is very important to reduce lead-time of manufacturing system constructions. At the manufacturing system implementation stage, it is important to make and evaluate facility control programs for a manufacturing cell, such as ladder programs for programmable logical controllers (PLCs) rapidly. However, before the manufacturing systems are implemented, methods to evaluate the facility control programs for the equipment while mixing and synchronizing real equipment and virtual factory models on the computers have not been developed. This difficulty is caused by the complexity of the manufacturing system composed of a great variety of equipment, and stopped precise and rapid support of a manufacturing engineering process. In this paper, a manufacturing engineering environment (MEE) to support manufacturing engineering processes using simulation technologies is proposed. MEE consists of a manufacturing cell simulation environment (MCSE) and a distributed simulation environment (DSE). MCSE, which consists of a manufacturing cell simulator and a soft-wiring system, is emphatically proposed in detail. MCSE realizes making and evaluating facility control programs by using virtual factory models on computers before manufacturing systems are implemented.
A collision model for safety evaluation of autonomous intelligent cruise control.
Touran, A; Brackstone, M A; McDonald, M
1999-09-01
This paper describes a general framework for safety evaluation of autonomous intelligent cruise control in rear-end collisions. Using data and specifications from prototype devices, two collision models are developed. One model considers a train of four cars, one of which is equipped with autonomous intelligent cruise control. This model considers the car in front and two cars following the equipped car. In the second model, none of the cars is equipped with the device. Each model can predict the possibility of rear-end collision between cars under various conditions by calculating the remaining distance between cars after the front car brakes. Comparing the two collision models allows one to evaluate the effectiveness of autonomous intelligent cruise control in preventing collisions. The models are then subjected to Monte Carlo simulation to calculate the probability of collision. Based on crash probabilities, an expected value is calculated for the number of cars involved in any collision. It is found that given the model assumptions, while equipping a car with autonomous intelligent cruise control can significantly reduce the probability of the collision with the car ahead, it may adversely affect the situation for the following cars.
Burnett, E; Curran, E; Loveday, H P; Kiernan, M A; Tannahill, M
2014-01-01
Healthcare is delivered in a dynamic environment with frequent changes in populations, methods, equipment and settings. Infection prevention and control practitioners (IPCPs) must ensure that they are competent in addressing the challenges they face and are equipped to develop infection prevention and control (IPC) services in line with a changing world of healthcare provision. A multifaceted Framework was developed to assist IPCPs to enhance competence at an individual, team and organisational level to enable quality performance and improved quality of care. However, if these aspirations are to be met, it is vital that competency frameworks are fit for purpose or they risk being ignored. The aim of this unique study was to evaluate short and medium term outcomes as set out in the Outcome Logic Model to assist with the evaluation of the impact and success of the Framework. This study found that while the Framework is being used effectively in some areas, it is not being used as much or in the ways that were anticipated. The findings will enable future work on revision, communication and dissemination, and will provide intelligence to those initiating education and training in the utilisation of the competences.
Curran, E; Loveday, HP; Kiernan, MA; Tannahill, M
2013-01-01
Healthcare is delivered in a dynamic environment with frequent changes in populations, methods, equipment and settings. Infection prevention and control practitioners (IPCPs) must ensure that they are competent in addressing the challenges they face and are equipped to develop infection prevention and control (IPC) services in line with a changing world of healthcare provision. A multifaceted Framework was developed to assist IPCPs to enhance competence at an individual, team and organisational level to enable quality performance and improved quality of care. However, if these aspirations are to be met, it is vital that competency frameworks are fit for purpose or they risk being ignored. The aim of this unique study was to evaluate short and medium term outcomes as set out in the Outcome Logic Model to assist with the evaluation of the impact and success of the Framework. This study found that while the Framework is being used effectively in some areas, it is not being used as much or in the ways that were anticipated. The findings will enable future work on revision, communication and dissemination, and will provide intelligence to those initiating education and training in the utilisation of the competences. PMID:28989348
Emergency and trauma care in Pakistan: a cross-sectional study of healthcare levels
Razzak, Junaid A; Baqir, Syed M; Khan, Uzma Rahim; Heller, David; Bhatti, Junaid; Hyder, Adnan A
2015-01-01
Background The importance of emergency medical care for the successful functioning of health systems has been increasingly recognised. This study aimed to evaluate emergency and trauma care facilities in four districts of the province of Sindh, Pakistan. Method We conducted a cross-sectional health facility survey in four districts of the province of Sindh in Pakistan using a modified version of WHO’s Guidelines for essential trauma care. 93 public health facilities (81 primary care facilities, nine secondary care hospitals, three tertiary hospitals) and 12 large private hospitals were surveyed. Interviews of healthcare providers and visual inspections of essential equipment and supplies as per guidelines were performed. A total of 141 physicians providing various levels of care were tested for their knowledge of basic emergency care using a validated instrument. Results Only 4 (44%) public secondary, 3 (25%) private secondary hospitals and all three tertiary care hospitals had designated emergency rooms. The majority of primary care health facilities had less than 60% of all essential equipments overall. Most of the secondary level public hospitals (78%) had less than 60% of essential equipments, and none had 80% or more. A fourth of private secondary care facilities and all tertiary care hospitals (n=3; 100%) had 80% or more essential equipments. The average percentage score on the physician knowledge test was 30%. None of the physicians scored above 60% correct responses. Conclusions The study findings demonstrated a gap in both essential equipment and provider knowledge necessary for effective emergency and trauma care. PMID:24157684
Elcin, Melih; Onan, Arif; Odabasi, Orhan; Saylam, Melahat; Ilhan, Handan; Daylan Kockaya, Pinar; Gurcuoglu, Ilker; Uckuyu, Yavuz; Cengiz, Duygu; Nacar, Osman Arikan
2016-12-01
Middle East Respiratory Syndrome (MERS) is a major global health threat. Prehospital professionals face the risk of infection as they work to save lives. They should be made aware of the disease and be prepared to handle such cases. The aims of our study are to develop a training program about the prehospital management of a MERS case using standardized patient (SP) scenarios, to evaluate the awareness and preparedness of the participants about MERS, and to evaluate the effectiveness of this training. We developed 5 scenarios using SPs and an observation form. We included paramedic students and emergency medical service (EMS) providers in our study. They were involved in the simulations. A total of 24 paramedic students and 33 EMS providers participated in our study. Sixteen (84%) of 19 teams recognized the possibility of MERS as a measure of their awareness in the baseline evaluation. The participants lacked donning and doffing personal protective equipments, which revealed their baseline level of preparedness for MERS. Certain improvements in donning and doffing personal protective equipment were observed in the posttraining evaluation. The participants provided positive feedback on the training program. The training program was appropriate for both paramedic students and EMS providers. A positive educational climate was created. Because the main concerns of this study were awareness and preparedness, which required human interaction, the SP methodology was the optimal simulation modality.
A clinical evaluation of four non-Luer spinal needle and syringe systems.
Kinsella, S M; Goswami, A; Laxton, C; Kirkham, L; Wharton, N; Bowen, M
2012-11-01
We performed an evaluation of non-Luer spinal devices supplied by four manufacturers or suppliers: Polymedic; Pajunk; Sarstedt; and Smiths. For each supplier, 100 evaluations were performed using a 25-G 90-mm spinal needle, 3-ml syringe, 5-ml syringe and filter needle; for comparison, 100 evaluations were performed with our standard Luer equipment. The non-Luer devices were associated with more qualitative problems compared with the Luer devices, for example, poor feel of dural puncture (9-32% vs 10%, respectively), poor observation of cerebrospinal fluid in the hub (3-27% vs 0%), and connection problem of the syringe to the spinal needle (7-33% vs 0%). There was also more frequent failure to achieve the spinal injection due to equipment-related causes (4-7% vs 0%, respectively). Median (IQR [range]) numeric satisfaction scores for the spinal needles were: Luer 10 (9-10 [7-10]); Polymedic 7 (4-8 [0-10]; Pajunk 7 (5-8 [0-10]); Sarstedt 7 (6-8 [0-10]); and Smiths 9 (7-10 [0-10]) (p<0.0001). Satisfaction scores for all spinal equipment were: Luer 10 (9-10 [5-10]); Polymedic 8 (6-8 [0-10]); Pajunk 7 (5-7 [1-9]); Sarstedt 8 (6-8 [0-10]); and Smiths 8 (8-9 [2-10]) (p<0.0001). Between 21% and 75% of non-Luer evaluations were rated with satisfaction worse than the usual Luer needle compared with 0-10% rated better, depending on the needle type. Between 22% and 76% of non-Luer evaluations were rated with satisfaction worse than the usual Luer equipment compared with 0-14% rated better. Specific concerns included poor feel of tissue planes and observation of cerebrospinal fluid (Polymedic), difficulty with connection of the syringe to the spinal needle and trocar removal (Pajunk), poor feel of tissue planes and needle flexibility (Sarstedt) and difficulty with connection of the syringe to the spinal needle (Smiths). We could not demonstrate a short-term learning curve for the new devices. Decisions on purchasing and implementation of the new non-Luer equipment will have to acknowledge that clinicians may have greater technical problems and reduced satisfaction compared with the current equipment. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.
NASA Astrophysics Data System (ADS)
Vaganova, E. V.; Syryamkin, M. V.
2015-11-01
The purpose of the research is the development of evolutionary algorithms for assessments of promising scientific directions. The main attention of the present study is paid to the evaluation of the foresight possibilities for identification of technological peaks and emerging technologies in professional medical equipment engineering in Russia and worldwide on the basis of intellectual property items and neural network modeling. An automated information system consisting of modules implementing various classification methods for accuracy of the forecast improvement and the algorithm of construction of neuro-fuzzy decision tree have been developed. According to the study result, modern trends in this field will focus on personalized smart devices, telemedicine, bio monitoring, «e-Health» and «m-Health» technologies.
Shuttle payload S-band communications study
NASA Technical Reports Server (NTRS)
Springett, J. C.
1979-01-01
The work to identify, evaluate, and make recommendations concerning the functions and interfaces of those orbiter avionic subsystems which are dedicated to, or play some part in, handling communication signals (telemetry and command) to/from payloads (spacecraft) that will be carried into orbit by the shuttle is reported. Some principal directions of the research are: (1) analysis of the ability of the various avionic equipment to interface with and appropriately process payload signals; (2) development of criteria which will foster equipment compatibility with diverse types of payloads and signals; (3) study of operational procedures, especially those affecting signal acquisition; (4) trade-off analysis for end-to-end data link performance optimization; (5) identification of possible hardware design weakness which might degrade signal processing performance.
DOT National Transportation Integrated Search
2015-08-01
Research is currently being conducted to improve bridge inspection practices. One potential : improvement is the use of nondestructive testing equipment to supplement visual inspection. To : consider the costs and benefits of this equipment, data abo...
Development of a Multidisciplinary and Telemedicine Focused System Database.
Paštěka, Richard; Forjan, Mathias; Sauermann, Stefan
2017-01-01
Tele-rehabilitation at home is one of the promising approaches in increasing rehabilitative success and simultaneously decreasing the financial burden on the healthcare system. Novel and mostly mobile devices are already in use, but shall be used in the future to a higher extent for allowing at home rehabilitation processes at a high quality level. The combination of exercises, assessments and available equipment is the basic objective of the presented database. The database has been structured in order to allow easy-to-use and fast access for the three main user groups. Therapists - looking for exercise and equipment combinations - patients - rechecking their tasks for home exercises - and manufacturers - entering their equipment for specific use cases. The database has been evaluated by a proof of concept study and shows a high degree of applicability for the field of rehabilitative medicine. Currently it contains 110 exercises/assessments and 111 equipment/systems. Foundations of presented database are already established in the rehabilitative field of application, but can and will be enhanced in its functionality to be usable for a higher variety of medical fields and specifications.
A Study on Performance and Safety Tests of Electrosurgical Equipment.
Tavakoli Golpaygani, A; Movahedi, M M; Reza, M
2016-09-01
Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient's safety and management of the risks associated with the use of high and low frequency electrical currents on human body. The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public) was evaluated in one of the provinces of Iran according to international and national standards. The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.
A typewriting system operated by head movements, based on home-computer equipment.
Heuvelmans, A M; Mélotte, H E; Neve, J J
1990-06-01
For persons who cannot move their hands and legs we have designed a relatively inexpensive typewriting system which can be operated by movements of the head. The typewriter is made up of commercially available home computer equipment - i e, a computer including monitor and printer and a headset replacing the mouse. A user-friendly software program has been designed to replace the mouse button and to make this equipment act as a typewriter with simple text-editing features. Some ergonomics aspects of the typewriter set-up and the results of an evaluation of the typewriter by two patients suffering from amyotrophic lateral sclerosis (ALS) are given. Several factors relevant to the design, construction, evaluation and application of the typewriter are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takeda, Masatoshi; Komura, Toshiyuki; Hirotani, Tsutomu
1995-12-01
Annual failure probabilities of buildings and equipment were roughly evaluated for two fusion-reactor-like buildings, with and without seismic base isolation, in order to examine the effectiveness of the base isolation system regarding siting issues. The probabilities are calculated considering nonlinearity and rupture of isolators. While the probability of building failure for both buildings on the same site was almost equal, the function failures for equipment showed that the base-isolated building had higher reliability than the non-isolated building. Even if the base-isolated building alone is located on a higher seismic hazard area, it could compete favorably with the ordinary one inmore » reliability of equipment.« less
Safety and Health Hazard Observations in Hmong Farming Operations
Neitzel, R. L.; Krenz, J.; de Castro, A. B.
2014-01-01
Agricultural workers have a high risk of occupational injuries, illnesses, and fatalities. However, there are very few standardized tools available to assess safety and health in agricultural operations. Additionally, there are a number of groups of agricultural workers, including Hmong refugees and immigrants, for which virtually no information on safety and health conditions is available. This study developed an observation-based methodology for systematically evaluating occupational health and safety hazards in agriculture, and pilot-tested this on several small-scale Hmong farming operations. Each observation assessed of range of safety and health hazards (e.g., musculoskeletal hazards, dust and pollen, noise, and mechanical hazards), as well as on factors such as type of work area, presence of personal protective equipment, and weather conditions. Thirty-six observations were collected on nine farms. The most common hazards observed were bending at the back and lifting <50 pounds. Use of sharp tools without adequate guarding mechanisms, awkward postures, repetitive hand motions, and lifting >50 pounds were also common. The farming activities observed involved almost no power equipment, and no pesticide or chemical handling was observed. The use of personal protective equipment was uncommon. The results of this assessment agreed well with a parallel study of perceived safety and health hazards among Hmong agricultural workers. This study suggests that small-scale Hmong farming operations involve a variety of hazards, and that occupational health interventions may be warranted in this community. The study also demonstrates the utility of standardized assessment tools and mixed-method approaches to hazard evaluation. PMID:24911689
NASA Astrophysics Data System (ADS)
Brandan, M.-E.; Ruiz-Trejo, C.; Caspani, C. E. M.; Fleitas, I.; de-la-Mora, R.; Miranda, A. A.; Plazas, M.-C.; Betancourt, C.-M.; Borras, C.
2001-10-01
Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of radiology experts. We present preliminary results from mammographic imaging facilities. Evaluation of the equipment performance and dose measurements in 21 mammographic units show that, on the average, 75% of the units comply with recommendations issued by various organizations. An independent evaluation of the quality of the clinical images show strong variations among the different radiological services.
NASA Astrophysics Data System (ADS)
Clements, Jim; Robinson, Richard; Bunt, Leslie; Robinson, Joe
2011-06-01
A number of techniques have been utilized to evaluate the performance of Aircraft Survivability Equipment (ASE) against threat Man-Portable Air Defense Systems (MANPADS). These techniques include flying actual threat MANPADS against stationary ASE with simulated aircraft signatures, testing installed ASE systems against simulated threat signatures, and laboratory hardware-in-the-loop (HWIL) testing with simulated aircraft and simulated missile signatures. All of these tests lack the realism of evaluating installed ASE against in-flight MANPADS on a terminal homing intercept path toward the actual ASE equipped aircraft. This limitation is due primarily to the current inability to perform non-destructive MANPADS/Aircraft flight testing. The U.S. Army Aviation and Missile Research and Development and Engineering Center (AMRDEC) is working to overcome this limitation with the development of a recoverable surrogate MANPADS missile system capable of engaging aircraft equipped with ASE while guaranteeing collision avoidance with the test aircraft. Under its Missile Airframe Simulation Testbed - MANPADS (MAST-M) program, the AMRDEC is developing a surrogate missile system which will utilize actual threat MANPADS seeker/guidance sections to control the flight of a surrogate missile which will perform a collision avoidance and recovery maneuver prior to intercept to insure non-destructive test and evaluation of the ASE and reuse of the MANPADS seeker/guidance section. The remainder of this paper provides an overview of this development program and intended use.
High-speed road profile equipment evaluation.
DOT National Transportation Integrated Search
1966-01-01
The importance of evaluating the relative smoothness of pavements is well recognized in the highway profession. In the past, however, this evaluation has been largely a matter of : qualitative judgment. Such evaluations are useful in serviceability-p...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kardas, A.
1987-10-01
A kerosene heater equipped with a dual-chamber combustor was procured, tested, and technically evaluated to determine its applicability to natural gas combustion. The kerosene heater was found to have nitric oxide (NO), nitrogen dioxide (NO/sub 2/), and carbon monoxide (CO) emissions of 0.0)2, 0.006 and 0.02 lb/10/sup 6/ Btu input, respectively, much lower than those of blue-flame natural-gas combustors. A basic study was conducted to understand the interaction between kerosene combustion and the surrounding metal sleeves forming the dual chamber. Combustion characteristics of kerosene and natural gas were compared to formulate potential designs of low-emitting natural gas combustors. Three conceptsmore » were developed for low-emitting burners: an atmospheric burner to replace the kerosene wick in the dual chamber; the same concept with a powered vent; and a two-stage system equipped with a powered vent.« less
Milosevic, Matija; McConville, Kristiina M Valter
2012-01-01
Operation of handheld power tools results in exposure to hand-arm vibrations, which over time lead to numerous health complications. The objective of this study was to evaluate protective equipment and working techniques for the reduction of vibration exposure. Vibration transmissions were recorded during different work techniques: with one- and two-handed grip, while wearing protective gloves (standard, air and anti-vibration gloves) and while holding a foam-covered tool handle. The effect was examined by analyzing the reduction of transmitted vibrations at the wrist. The vibration transmission was recorded with a portable device using a triaxial accelerometer. The results suggest large and significant reductions of vibration with appropriate safety equipment. Reductions of 85.6% were achieved when anti-vibration gloves were used. Our results indicated that transmitted vibrations were affected by several factors and could be measured and significantly reduced.
Botelho, Anabela; Ferreira Dias, Marta; Ferreira, Carla; Pinto, Lígia M Costa
2016-10-01
This paper aims to ascertain the efficacy and acceptability of five incentive schemes for the take-back of waste electrical and electronic equipment in Portugal, focusing in consumers' perspectives. It assesses users' perception of these items, evaluating the motivations and interests they have concerning the market of waste electrical and electronic equipment. Results indicate, on one hand, a lack of awareness by consumers about the process of take-back of their equipment. On the other hand, results show that information conditions and socio-demographic factors affect consumers' motivations for returning the electrical and electronic equipment at the end of life. In this context, it can be concluded that, in Portugal, the market for the recovery of waste electrical and electronic equipment is still in its infancy. © The Author(s) 2016.
Neck muscle activity in helicopter pilots: effect of position and helmet-mounted equipment.
Thuresson, Marcus; Ang, Björn; Linder, Jan; Harms-Ringdahl, Karin
2003-05-01
Helicopter pilots usually work in unfavorable ergonomic positions, often with bulky head-worn equipment during flying missions. The purpose of this study was to evaluate and compare immediate muscle response in the dorsal neck muscles to different positions with a variety of head-worn equipment. Fourteen healthy male helicopter pilots volunteered for this study. EMG activity in the upper and lower dorsal neck muscles and the trapezius muscle was measured in a laboratory situation for 5 s in different sitting positions (neutral, trunk inclined 20 degrees, neck flexed 20 degrees), including registration of a 30 degrees left and right rotation in every position; all measurements were performed while wearing a helmet, a helmet and night vision goggles (hNVG), and a helmet, night vision goggles, and counterweight (hCW), in random order. There was significant higher EMG activity in the upper neck with hNVG and hCW than with the helmet only when comparing the mean activity level of all positions. However, there was no significant difference in EMG activity between any variations of head-worn equipment when comparing activity levels during each position separately. In the upper and lower neck, respectively, there was significantly higher muscle activity during the ipsilateral rotated positions plus neck flexion and trunk inclination than in most other positions. The increased load caused by different positions seems to have a greater influence on muscle activity than the increased load of the head-worn equipment, which must be considered when designing helicopter work-places.
LABORATORY EVALUATION OF NONSTICK COATINGS TO REDUCE INK ADHESION TO PRINTING PRESS COMPONENTS
The report gives results of a project to identify surface coatings or preparations that might reduce and/or eliminate the need for solvent cleaning of ink-feed-system components of printing equipment. The study was designed to provide qualitative, but not quantitative, results. T...
Intermodal rail yards are important nodes in the freight transportation network, where freight is organized and moved from one mode of transport to another, critical equipment is serviced, and freight is routed to its next destination. Rail yard environments are also areas with ...
Reflecting on the Works and Contributions of Garth Boomer
ERIC Educational Resources Information Center
Dawson, Tamara
2013-01-01
In order to adequately prepare students for the summative requirements of Year 12, tertiary education and life beyond school, it is essential that all students are equipped with the literary skills necessary for discerning ideas, evaluating perspectives and appreciating texts within their world (Queensland Studies Authority, 2010, p. 29). Such…
40 CFR 799.9420 - TSCA carcinogenicity.
Code of Federal Regulations, 2010 CFR
2010-07-01
... inhalation equipment designed to sustain a minimum air flow of 10 air changes per hr, an adequate oxygen... sufficient. If pretest measurements are not within 10% of each other, three to four measurements should be... methods including significance criteria shall be selected during the design of the study. (2) Evaluation...
40 CFR 799.9420 - TSCA carcinogenicity.
Code of Federal Regulations, 2011 CFR
2011-07-01
... inhalation equipment designed to sustain a minimum air flow of 10 air changes per hr, an adequate oxygen... sufficient. If pretest measurements are not within 10% of each other, three to four measurements should be... methods including significance criteria shall be selected during the design of the study. (2) Evaluation...
40 CFR 799.9420 - TSCA carcinogenicity.
Code of Federal Regulations, 2012 CFR
2012-07-01
... inhalation equipment designed to sustain a minimum air flow of 10 air changes per hr, an adequate oxygen... sufficient. If pretest measurements are not within 10% of each other, three to four measurements should be... methods including significance criteria shall be selected during the design of the study. (2) Evaluation...
40 CFR 799.9420 - TSCA carcinogenicity.
Code of Federal Regulations, 2013 CFR
2013-07-01
... inhalation equipment designed to sustain a minimum air flow of 10 air changes per hr, an adequate oxygen... sufficient. If pretest measurements are not within 10% of each other, three to four measurements should be... methods including significance criteria shall be selected during the design of the study. (2) Evaluation...
40 CFR 799.9420 - TSCA carcinogenicity.
Code of Federal Regulations, 2014 CFR
2014-07-01
... inhalation equipment designed to sustain a minimum air flow of 10 air changes per hr, an adequate oxygen... sufficient. If pretest measurements are not within 10% of each other, three to four measurements should be... methods including significance criteria shall be selected during the design of the study. (2) Evaluation...
Effect of Natural Antimicrobials to reduce Biofilm formed by Environmental Isolates of Salmonella
USDA-ARS?s Scientific Manuscript database
Biofilm formation by enteric pathogens on food and equipment surfaces is a concern because sessile bacteria within biofilms are resistant to cleaning and disinfection. The formation of biofilms by Salmonella enterica on food surfaces has been documented. The purpose of this study was to evaluate t...
2009-06-12
these past efforts, DOD recognized the incredible potential that medium and high altitude UAS held for all uniformed services. A pilotless aircraft...from aircraft, ships, missiles, automobiles and related military support equipment. 30 RDT&E: Research, Development, Test and Evaluation pay for
ERIC Educational Resources Information Center
Kirchner, Martha
A self-instructional unit on eating habits and customs in Germany is presented for the high school student studying second-year German. Notes to the teacher outline general goals of the unit, specific objectives, additional activities, equipment, and student evaluation. The general goals are: to be able to eat a meal in Germany without offending…
ERIC Educational Resources Information Center
Caudrey, David J.; Seeger, Barry R.
1983-01-01
A study was undertaken to determine the extent to which a rehabilitation engineering service met the needs and expectations of 100 patients (or parents of child patients). The patients were interviewed an average of 16 weeks after a new piece of equipment was supplied. (Author)
Technostress: A Content Analysis.
ERIC Educational Resources Information Center
Clute, Robin
This paper reports on a study that explores the literature of technostress--the anxiety over using technological equipment--both inside and outside of the library field. Fifty-eight unique articles were abstracted and evaluated. By using a coding sheet a measurement was taken of symptoms, reasons given for the "modern disease," and…
Zhang, Guomin; Sandanayake, Malindu; Setunge, Sujeeva; Li, Chunqing; Fang, Jun
2017-02-01
Emissions from equipment usage and transportation at the construction stage are classified as the direct emissions which include both greenhouse gas (GHG) and non-GHG emissions due to partial combustion of fuel. Unavailability of a reliable and complete inventory restricts an accurate emission evaluation on construction work. The study attempts to review emission factor standards readily available worldwide for estimating emissions from construction equipment. Emission factors published by United States Environmental Protection Agency (US EPA), Australian National Greenhouse Accounts (AUS NGA), Intergovernmental Panel on Climate Change (IPCC) and European Environmental Agency (EEA) are critically reviewed to identify their strengths and weaknesses. A selection process based on the availability and applicability is then developed to help identify the most suitable emission factor standards for estimating emissions from construction equipment in the Australian context. A case study indicates that a fuel based emission factor is more suitable for GHG emission estimation and a time based emission factor is more appropriate for estimation of non-GHG emissions. However, the selection of emission factor standards also depends on factors like the place of analysis (country of origin), data availability and the scope of analysis. Therefore, suitable modifications and assumptions should be incorporated in order to represent these factors. Copyright © 2016 Elsevier Ltd. All rights reserved.
Evaluation of Bluetooth as a replacement for cables in intensive care and surgery.
Wallin, Mats K E B; Wajntraub, Samson
2004-03-01
In today's intensive care and surgery, a great number of cables are attached to patients. These cables can make the care and nursing of the patient difficult. Replacing them with wireless communications technology would facilitate patient care. Bluetooth is a modern radio technology developed specifically to replace cables between different pieces of communications equipment. In this study we sought to determine whether Bluetooth is a suitable replacement for cables in intensive care and during surgery with respect to electromagnetic compatibility. The following questions were addressed: Does Bluetooth interfere with medical equipment? And does the medical equipment decrease the quality of the Bluetooth communication? A Bluetooth link, simulating a patient monitoring system, was constructed with two laptops. The prototype was then used in laboratory and clinical tests according to American standards at the Karolinska Hospital in Stockholm. The tests, which included 44 different pieces of medical equipment, indicated that Bluetooth does not cause any interference. The tests also showed that the hospital environment does not affect the Bluetooth communication negatively. Bluetooth, a new radio technology transmitting at 2.4 GHz, was tested in a clinical setting. The study showed that a single Bluetooth link was robust and electromagnetically compatible with the tested electronic medical devices.
NASA Technical Reports Server (NTRS)
Killian, D. A.; Menninger, F. J.; Gorman, T.; Glenn, P.
1988-01-01
The Technical Facilities Controller is a microprocessor-based energy management system that is to be implemented in the Deep Space Network facilities. This system is used in conjunction with facilities equipment at each of the complexes in the operation and maintenance of air-conditioning equipment, power generation equipment, power distribution equipment, and other primary facilities equipment. The implementation of the Technical Facilities Controller was completed at the Goldstone Deep Space Communications Complex and is now operational. The installation completed at the Goldstone Complex is described and the utilization of the Technical Facilities Controller is evaluated. The findings will be used in the decision to implement a similar system at the overseas complexes at Canberra, Australia, and Madrid, Spain.
An evaluation of Skylab habitability hardware
NASA Technical Reports Server (NTRS)
Stokes, J.
1974-01-01
For effective mission performance, participants in space missions lasting 30-60 days or longer must be provided with hardware to accommodate their personal needs. Such habitability hardware was provided on Skylab. Equipment defined as habitability hardware was that equipment composing the food system, water system, sleep system, waste management system, personal hygiene system, trash management system, and entertainment equipment. Equipment not specifically defined as habitability hardware but which served that function were the Wardroom window, the exercise equipment, and the intercom system, which was occasionally used for private communications. All Skylab habitability hardware generally functioned as intended for the three missions, and most items could be considered as adequate concepts for future flights of similar duration. Specific components were criticized for their shortcomings.
A demonstration of the GHEMFIX solidification/stabilization process was conducted under the United States Environmental Protection Agency`s (EPA) Superfund Innovative Technology Evaluation (SITE) program. The demonstration was conducted in March 1989, at the Portable Equipment Sa...
10 CFR 216.4 - Evaluation by DOE of applications.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Energy DEPARTMENT OF ENERGY OIL MATERIALS ALLOCATION AND PRIORITY PERFORMANCE UNDER CONTRACTS OR ORDERS... described supplies of materials and equipment, services, or facilities are critical and essential to the... and equipment, services, or facilities described in the application are critical and essential to an...
10 CFR 216.4 - Evaluation by DOE of applications.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Energy DEPARTMENT OF ENERGY OIL MATERIALS ALLOCATION AND PRIORITY PERFORMANCE UNDER CONTRACTS OR ORDERS... described supplies of materials and equipment, services, or facilities are critical and essential to the... and equipment, services, or facilities described in the application are critical and essential to an...
10 CFR 216.4 - Evaluation by DOE of applications.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Energy DEPARTMENT OF ENERGY OIL MATERIALS ALLOCATION AND PRIORITY PERFORMANCE UNDER CONTRACTS OR ORDERS... described supplies of materials and equipment, services, or facilities are critical and essential to the... and equipment, services, or facilities described in the application are critical and essential to an...
10 CFR 216.4 - Evaluation by DOE of applications.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Energy DEPARTMENT OF ENERGY OIL MATERIALS ALLOCATION AND PRIORITY PERFORMANCE UNDER CONTRACTS OR ORDERS... described supplies of materials and equipment, services, or facilities are critical and essential to the... and equipment, services, or facilities described in the application are critical and essential to an...
30 CFR 18.35 - Portable (trailing) cables and cords.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction... used to conduct electrical energy to face equipment shall conform to the following: (1) Have each conductor of a current-carrying capacity consistent with the Insulated Power Cable Engineers Association...
30 CFR 18.35 - Portable (trailing) cables and cords.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction... used to conduct electrical energy to face equipment shall conform to the following: (1) Have each conductor of a current-carrying capacity consistent with the Insulated Power Cable Engineers Association...
30 CFR 18.35 - Portable (trailing) cables and cords.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction... used to conduct electrical energy to face equipment shall conform to the following: (1) Have each conductor of a current-carrying capacity consistent with the Insulated Power Cable Engineers Association...
30 CFR 18.35 - Portable (trailing) cables and cords.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction... used to conduct electrical energy to face equipment shall conform to the following: (1) Have each conductor of a current-carrying capacity consistent with the Insulated Power Cable Engineers Association...
10 CFR 216.4 - Evaluation by DOE of applications.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Energy DEPARTMENT OF ENERGY OIL MATERIALS ALLOCATION AND PRIORITY PERFORMANCE UNDER CONTRACTS OR ORDERS... described supplies of materials and equipment, services, or facilities are critical and essential to the... and equipment, services, or facilities described in the application are critical and essential to an...
30 CFR 18.97 - Inspection of machines; minimum requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Field Approval of Electrically Operated Mining Equipment § 18.97 Inspection of machines; minimum... shall be conducted by an electrical representative and such inspection shall include: (1) Examination of...
30 CFR 18.97 - Inspection of machines; minimum requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Field Approval of Electrically Operated Mining Equipment § 18.97 Inspection of machines; minimum... shall be conducted by an electrical representative and such inspection shall include: (1) Examination of...
40 CFR 51.354 - Adequate tools and resources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... assurance, data analysis and reporting, and the holding of hearings and adjudication of cases. A portion of... supply of vehicles for covert auditing, test equipment and facilities for program evaluation, and computers capable of data processing, analysis, and reporting. Equipment or equivalent services may be...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keck, R.D.
1997-01-21
The purpose of this document is to record the technical evaluation of the Limiting Condition for Operation (LCO) described in the Plutonium Finishing Plant (PFP) Operational Safety Requirements, WHC-SD-CP-OSR- 010, Rev. 0. Kay 1994, Section 3.2.3, `Supply Ventilation System Seismic Shutdown.` This document, with its appendices, provides the following: 1. The system functional requirements for determining system operability (Section 3). 2. Evaluations of equipment to determine the safety boundary for the system (Section 4). 3. A list of annotated drawings which show the safety envelope boundaries (Appendix C). 4. A list of the safety envelope equipment (Appendix B). 5. Functionalmore » requirements for the individual safety envelope equipment, including appropriate setpoints and process parameters (Section 4.1). 6. A list of the operational, maintenance and surveillance procedures necessary to operate and maintain the system equipment within the safety envelope (Sections 5 and 6 and Appendix A).« less
Delivery of a national home safety equipment scheme in England: a survey of local scheme leaders.
Mulvaney, C A; Watson, M C; Hamilton, T; Errington, G
2013-11-01
Unintentional home injuries sustained by preschool children are a major cause of morbidity in the UK. Home safety equipment schemes may reduce home injury rates. In 2009, the Royal Society for the Prevention of Accidents was appointed as central coordinator of a two-year, £18m national home safety equipment scheme in England. This paper reports the findings from a national survey of all scheme leaders responsible for local scheme delivery. A questionnaire mailed to all local scheme leaders sought details of how the schemes were operated locally; barriers and facilitators to scheme implementation; evaluation of the local scheme and its sustainability. A response rate of 73% was achieved. Health visitors and family support workers played a key role in both the identification of eligible families and performing home safety checks. The majority of local scheme leaders (94.6%) reported that they thought their local scheme had been successful in including those families considered 'harder to engage'. Many scheme leaders (72.4%) reported that they had evaluated the provision of safety equipment in their scheme and over half (56.6%) stated that they would not be able to continue the scheme once funding ceased. Local schemes need support to effectively evaluate their scheme and to seek sustainability funding to ensure the future of the scheme. There remains a lack of evidence of whether the provision of home safety equipment reduces injuries in preschool children.
Browne, Annette J; Varcoe, Colleen; Ford-Gilboe, Marilyn; Wathen, C Nadine
2015-12-14
The primary health care (PHC) sector is increasingly relevant as a site for population health interventions, particularly in relation to marginalized groups, where the greatest gains in health status can be achieved. The purpose of this paper is to provide an overview of an innovative multi-component, organizational-level intervention designed to enhance the capacity of PHC clinics to provide equity-oriented care, particularly for marginalized populations. The intervention, known as EQUIP, is being implemented in Canada in four diverse PHC clinics serving populations who are impacted by structural inequities. These PHC clinics serve as case studies for the implementation and evaluation of the EQUIP intervention. We discuss the evidence and theory that provide the basis for the intervention, describe the intervention components, and discuss the methods used to evaluate the implementation and impact of the intervention in diverse contexts. Research and theory related to equity-oriented care, and complexity theory, are central to the design of the EQUIP intervention. The intervention aims to enhance capacity for equity-oriented care at the staff level, and at the organizational level (i.e., policy and operations) and is novel in its dual focus on: (a) Staff education: using standardized educational models and integration strategies to enhance staff knowledge, attitudes and practices related to equity-oriented care in general, and cultural safety, and trauma- and violence-informed care in particular, and; (b) Organizational integration and tailoring: using a participatory approach, practice facilitation, and catalyst grants to foster shifts in organizational structures, practices and policies to enhance the capacity to deliver equity-oriented care, improve processes of care, and shift key client outcomes. Using a mixed methods, multiple case-study design, we are examining the impact of the intervention in enhancing staff knowledge, attitudes and practices; improving processes of care; shifting organizational policies and structures; and improving selected client outcomes. The multiple case study design provides an ideal opportunity to study the contextual factors shaping the implementation, uptake and impact of our tailored intervention within diverse PHC settings. The EQUIP intervention illustrates the complexities involved in enhancing the PHC sector's capacity to provide equity-oriented care in real world clinical contexts.
Bovea, María D; Ibáñez-Forés, Valeria; Pérez-Belis, Victoria; Quemades-Beltrán, Pilar
2016-07-01
This study proposes a general methodology for assessing and estimating the potential reuse of small waste electrical and electronic equipment (sWEEE), focusing on devices classified as domestic appliances. Specific tests for visual inspection, function and safety have been defined for ten different types of household appliances (vacuum cleaner, iron, microwave, toaster, sandwich maker, hand blender, juicer, boiler, heater and hair dryer). After applying the tests, reuse protocols have been defined in the form of easy-to-apply checklists for each of the ten types of appliance evaluated. This methodology could be useful for reuse enterprises, since there is a lack of specific protocols, adapted to each type of appliance, to test its potential of reuse. After applying the methodology, electrical and electronic appliances (used or waste) can be segregated into three categories: the appliance works properly and can be classified as direct reuse (items can be used by a second consumer without prior repair operations), the appliance requires a later evaluation of its potential refurbishment and repair (restoration of products to working order, although with possible loss of quality) or the appliance needs to be finally discarded from the reuse process and goes directly to a recycling process. Results after applying the methodology to a sample of 87.7kg (96 units) show that 30.2% of the appliances have no potential for reuse and should be diverted for recycling, while 67.7% require a subsequent evaluation of their potential refurbishment and repair, and only 2.1% of them could be directly reused with minor cleaning operations. This study represents a first approach to the "preparation for reuse" strategy that the European Directive related to Waste Electrical and Electronic Equipment encourages to be applied. However, more research needs to be done as an extension of this study, mainly related to the identification of the feasibility of repair or refurbishment operations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Specialized computer system to diagnose critical lined equipment
NASA Astrophysics Data System (ADS)
Yemelyanov, V. A.; Yemelyanova, N. Y.; Morozova, O. A.; Nedelkin, A. A.
2018-05-01
The paper presents data on the problem of diagnosing the lining condition at the iron and steel works. The authors propose and describe the structure of the specialized computer system to diagnose critical lined equipment. The relative results of diagnosing lining condition by the basic system and the proposed specialized computer system are presented. To automate evaluation of lining condition and support in making decisions regarding the operation mode of the lined equipment, the specialized software has been developed.
Garmer, Karin; Sperling, Lena; Forsberg, Anette
2002-01-01
A need for a hand-ergonomics training kit has been identified to increase critical thinking concerning choice of hand tools. This study deals with the design, use and evaluation of a hand-ergonomics training kit for use in ergonomics training programmes. The effects on awareness of hand ergonomics among training course participants have been evaluated by means of a questionnaire and interviews at a car production plant in Sweden. The evaluation was carried out about one and a half years after training with the hand-ergonomics training kit. The training kit consists of a guide to practical exercises, equipment for measuring hand size and strength, examples of hand tools for use in practical exercises, equipment for testing and evaluating the hand tools and checklists and judgement forms for qualitative evaluation. In addition, the kit contains relevant scientifically based reference reports on hand ergonomics. The evaluation showed that the practical exercises with the hand-ergonomic training kit had, to a remarkable extent, increased individuals' awareness of anthropometric differences and of the importance of ergonomically well-designed hand tools. After the practical exercises with the training kit, communication within the plant when choosing hand tools seems to be based on objective criteria to a higher degree, however, the results indicate that this communication could be further improved.
Evaluation of a standard test method for screening fuels in soils
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorini, S.S.; Schabron, J.F.
1996-12-31
A new screening method for fuel contamination in soils was recently developed as American Society for Testing and Materials (ASTM) Method D-5831-95, Standard Test Method for Screening Fuels in Soils. This method uses low-toxicity chemicals and can be sued to screen organic- rich soils, as well as being fast, easy, and inexpensive to perform. Fuels containing aromatic compounds, such as diesel fuel and gasoline, as well as other aromatic-containing hydrocarbon materials, such as motor oil, crude oil, and cola oil, can be determined. The screening method for fuels in soils was evaluated by conducting a Collaborative study on the method.more » In the Collaborative study, a sand and an organic soil spiked with various concentrations of diesel fuel were tested. Data from the Collaborative study were used to determine the reproducibility (between participants) and repeatability (within participants) precision of the method for screening the test materials. The Collaborative study data also provide information on the performance of portable field equipment (patent pending) versus laboratory equipment for performing the screening method and a comparison of diesel concentration values determined using the screening method versus a laboratory method.« less
[Cost and effectiveness of exercise therapy for patients with essential hypertension].
Harada, A; Kawakubo, K; Lee, J S; Fukuda, T; Kobayashi, Y
2001-09-01
While exercise therapy is established as an appropriate treatment for essential hypertension, its economic profile has not been fully evaluated. The purpose of this study is to evaluate cost and effectiveness in comparison with drug therapy. The study subjects were hypertensive patients under treatment at an outpatient clinic. Fifty-seven were selected on a non-randomized manner for exercise therapy and the same number of patients was chosen for drug therapy after matching age, sex, medication and complications. The following data were collected during three months of intervention. 1) Effectiveness: Change of systolic blood pressure before and after the intervention. 2) Cost: equipment, personnel expenses for exercise therapy and fees for health check-ups (exercise therapy); fees for consultation, laboratory examination and medications (drug therapy), 3) Cost-effectiveness: cost per 1 mmHg systolic blood pressure reduction. We evaluated the variance of cost-effectiveness by controlling the number of program participants, personnel expenses, and equipment expenses of exercise therapy. We also simulated how the cost-effectiveness of exercise therapy would improve by modifying the number of exercise participants, personnel and equipment expenses. The cost-effectiveness per 1 mmHg systolic blood pressure reduction was yen 11,268 for exercise therapy and yen 2,441 for drug therapy. Extending program facilities and increasing the number of participants would improve the cost-effectiveness of exercise therapy, but there were limitations to how far this could be achieved in the hospital setting. Differences in cost-effectiveness between exercise and drug therapies are attributed to differences in personnel expenses. Although they could be reduced by managerial effort of the hospital to some extent, outsourcing of exercise therapy to community-based facilities should be considered.
Post test review of a single car test of multi-level passenger equipment
DOT National Transportation Integrated Search
2008-04-22
The single car test of multi-level equipment described in : this paper was designed to help evaluate the crashworthiness of : a multi-level car in a controlled collision. The data collected : from this test will be used to refine engineering models. ...
10 CFR 71.115 - Control of purchased material, equipment, and services.
Code of Federal Regulations, 2010 CFR
2010-01-01
... RADIOACTIVE MATERIAL Quality Assurance § 71.115 Control of purchased material, equipment, and services. (a... source evaluation and selection, objective evidence of quality furnished by the contractor or... available, this documentary evidence for the life of the package to which it applies. The licensee...
10 CFR 71.115 - Control of purchased material, equipment, and services.
Code of Federal Regulations, 2014 CFR
2014-01-01
... RADIOACTIVE MATERIAL Quality Assurance § 71.115 Control of purchased material, equipment, and services. (a... source evaluation and selection, objective evidence of quality furnished by the contractor or... available, this documentary evidence for the life of the package to which it applies. The licensee...
10 CFR 71.115 - Control of purchased material, equipment, and services.
Code of Federal Regulations, 2011 CFR
2011-01-01
... RADIOACTIVE MATERIAL Quality Assurance § 71.115 Control of purchased material, equipment, and services. (a... source evaluation and selection, objective evidence of quality furnished by the contractor or... available, this documentary evidence for the life of the package to which it applies. The licensee...
10 CFR 71.115 - Control of purchased material, equipment, and services.
Code of Federal Regulations, 2013 CFR
2013-01-01
... RADIOACTIVE MATERIAL Quality Assurance § 71.115 Control of purchased material, equipment, and services. (a... source evaluation and selection, objective evidence of quality furnished by the contractor or... available, this documentary evidence for the life of the package to which it applies. The licensee...
10 CFR 71.115 - Control of purchased material, equipment, and services.
Code of Federal Regulations, 2012 CFR
2012-01-01
... RADIOACTIVE MATERIAL Quality Assurance § 71.115 Control of purchased material, equipment, and services. (a... source evaluation and selection, objective evidence of quality furnished by the contractor or... available, this documentary evidence for the life of the package to which it applies. The licensee...
DOT National Transportation Integrated Search
1979-10-01
This report discusses the effect on a railroad's legal liability for railroad-highway grade crossing accident costs when that railroad uses innovative grade crossing safety equipment. Its purpose is to evaluate the assertion that a railroad's use of ...
Effective Approaches to Disorientation Familiarization for Aviation Personnel.
ERIC Educational Resources Information Center
Collins, William E.
Techniques are discussed for providing familiarization of aviation personnel with disorientation problems (dizziness). Procedures are spelled out in detail. Methods of modifying existing equipment as well as an evaluation of available commercial equipment, are presented. The techniques have been used with notable success both at the Civil…
DOT National Transportation Integrated Search
2008-05-31
To ensure a level of occupant volume protection, passenger railway : equipment operating on mainline railroads in the United States must currently be : designed to resist an 800,000 pound compressive load applied statically to the : underframe. An al...
30 CFR 18.20 - Quality of material, workmanship, and design.
Code of Federal Regulations, 2011 CFR
2011-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES... facilitate inspection and maintenance. (b) MSHA will test only electrical equipment that in the opinion of... shall be accessible for field inspection, where practicable. (e) An audible warning device shall be...
30 CFR 18.96 - Preparation of machines for inspection; requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Field Approval of Electrically Operated Mining Equipment § 18.96 Preparation of machines for inspection... place at which a field approval investigation will be conducted with respect to any machine, the...
30 CFR 18.93 - Application for field approval; filing procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Application for field approval; filing... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Field Approval of Electrically Operated Mining Equipment § 18.93 Application for field approval; filing...
30 CFR 18.20 - Quality of material, workmanship, and design.
Code of Federal Regulations, 2010 CFR
2010-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES... facilitate inspection and maintenance. (b) MSHA will test only electrical equipment that in the opinion of... shall be accessible for field inspection, where practicable. (e) An audible warning device shall be...
30 CFR 18.93 - Application for field approval; filing procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Application for field approval; filing... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Field Approval of Electrically Operated Mining Equipment § 18.93 Application for field approval; filing...
30 CFR 18.96 - Preparation of machines for inspection; requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Field Approval of Electrically Operated Mining Equipment § 18.96 Preparation of machines for inspection... place at which a field approval investigation will be conducted with respect to any machine, the...
Relationship between NDVI at early bloom and yield in germplasm evaluation trials
USDA-ARS?s Scientific Manuscript database
The use of high-throughput phenotyping (HTP) equipment is expanding as it offers the potential to increase the efficiency of making selections in cotton (Gossypium hirsutum L.) improvement programs. Measurements often being collected on HTP field equipment include normalized difference vegetative in...
Blue Light and Ultraviolet Radiation Exposure from Infant Phototherapy Equipment.
Pinto, Iole; Bogi, Andrea; Picciolo, Francesco; Stacchini, Nicola; Buonocore, Giuseppe; Bellieni, Carlo V
2015-01-01
Phototherapy is the use of light for reducing the concentration of bilirubin in the body of infants. Although it has become a mainstay since its introduction in 1958, a better understanding of the efficacy and safety of phototherapy applications seems to be necessary for improved clinical practices and outcomes. This study was initiated to evaluate workers' exposure to Optical Radiation from different types of phototherapy devices in clinical use in Italy. During infant phototherapy the staff monitors babies periodically for around 10 min every hour, and fixation of the phototherapy beam light frequently occurs: almost all operators work within 30 cm of the phototherapy source during monitoring procedures, with most of them commonly working at ≤25 cm from the direct or reflected radiation beam. The results of this study suggest that there is a great variability in the spectral emission of equipments investigated, depending on the types of lamps used and some phototherapy equipment exposes operators to blue light photochemical retinal hazard. Some of the equipment investigated presents relevant spectral emission also in the UVA region. Taking into account that the exposure to UV in childhood has been established as an important contributing factor for melanoma risk in adults and considering the high susceptibility to UV-induced skin damage of the newborn, related to his pigmentary traits, the UV exposure of the infant during phototherapy should be "as low as reasonably achievable," considering that it is unnecessary to the therapy. It is recommended that special safety training be provided for the affected employees: in particular, protective eyewear can be necessary during newborn assistance activities carried out in proximity of some sources. The engineering design of phototherapy equipment can be optimized. Specific requirements for photobiological safety of lamps used in the phototherapy equipment should be defined in the safety product standard for such equipment.
Evaluation of the Schmidt-STRATOS spreader.
DOT National Transportation Integrated Search
2005-07-01
In the fall of 2004, the Maine Department of Transportation (MAINEDOT) entered into an arrangement : with Schmidt International of St.Blasien, Germany to evaluate Schmidts STRATOS material spreader. : The MAINEDOT agreed to evaluate the equipment ...
Wiinberg, Stig; Samuelsson, Göran; Larsson, Stefan; Nilsson, Barbro; Jönsson, Patrik X; Ivarsson, Bodil; Olofsson, Per-Åke
2017-08-09
National recommendations in Sweden recommend a safety distance of 3 meter (m) between mobile phones and medical-electrical (ME) equipment in hospitals. A questionnaire was used to investigate how often mobile phones were reported to interfere with ME products in clinical practice across Sweden. The results confirmed that ME equipment can be affected by mobile phone use but, the risk of the patient's outcome being affected were minimal; no cases were identified which led to injury or death. In conclusion, the results support recommendations for a general safety distance of 0.5 m between mobile phones and ME equipment in care environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neymark, J.; Kennedy, M.; Judkoff, R.
This report documents a set of diagnostic analytical verification cases for testing the ability of whole building simulation software to model the air distribution side of typical heating, ventilating and air conditioning (HVAC) equipment. These cases complement the unitary equipment cases included in American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, which test the ability to model the heat-transfer fluid side of HVAC equipment.
First aid on field management in youth football.
Krutsch, Werner; Voss, Andreas; Gerling, Stephan; Grechenig, Stephan; Nerlich, Michael; Angele, Peter
2014-09-01
Sufficient first aid equipment is essential to treat injuries on football fields. Deficits in first aid on field are still present in youth football. Injury pattern in youth football over one season and first aid equipment in youth football were analyzed, retrospectively. PRICE and ABC procedure served as basic principles in emergency management to assess the need for first aid equipment on field. Considering financial limits and adapted on youth football injuries, sufficient first aid equipment for youth football was configured. 84% of 73 participating youth football teams had their own first aid kit, but the majority of them were insufficiently equipped. Team coaches were in 60% of all youth teams responsible for using first aid equipment. The injury evaluation presented 922 injuries to 1,778 youth players over one season. Frequently presented types of injury were contusions and sprains of the lower extremity. Based on the analyzed injury data in youth football, first aid equipment with 90 € is sufficient for 100% of all occurred youth football injuries. Current first aid equipment in youth football is insufficient. Scientific-based first aid equipment with 90 € is adequate to serve all injuries. Football coaches need education in first aid management.
NASA Technical Reports Server (NTRS)
1977-01-01
Information regarding the safety limits of hydrocarbons in liquid and gaseous oxygen, the steps taken for hydrocarbon removal from liquified gases, and the analysis of the contaminants was searched and the results are presented. The safety of hydrocarbons in gaseous systems was studied, and the latest hydrocarbon test equipment and methodology is reviewed. A detailed sampling and analysis plan is proposed to evaluate high pressure GN2 and LOX systems.
Yorioka, Katsuhiro; Oie, Shigeharu; Hayashi, Koji; Kimoto, Hiroo; Furukawa, Hiroyuki
2016-06-01
Although microbial contamination of ice machines has been reported, no previous study has addressed microbial contamination of ice produced by machines equipped with activated charcoal (AC) filters in hospitals. The aim of this study was to provide clinical data for evaluating AC filters to prevent microbial contamination of ice. We compared microbial contamination in ice samples produced by machines with (n = 20) and without an AC filter (n = 40) in Shunan City Shinnanyo Municipal Hospital. All samples from the ice machine equipped with an AC filter contained 10-116 CFUs/g of glucose nonfermenting gram-negative bacteria such as Pseudomonas aeruginosa and Chryseobacterium meningosepticum. No microorganisms were detected in samples from ice machines without AC filters. After the AC filter was removed from the ice machine that tested positive for Gram-negative bacteria, the ice was resampled (n = 20). Analysis found no contaminants. Ice machines equipped with AC filters pose a serious risk factor for ice contamination. New filter-use guidelines and regulations on bacterial detection limits to prevent contamination of ice in healthcare facilities are necessary.
75 FR 14575 - Voting Equipment Evaluations Phase III
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-26
..., Human Performance-Based Standards and Usability Testing. NIST Phase III research is designed to: (1... vendor equipment will not be released. Comparative information may be released in a blind manner... electronic poll book systems as well as software used for ballot design and creation. Dated: March 23, 2010...
Agricultural Equipment Technology: A Suggested 2-Year Post High School Curriculum.
ERIC Educational Resources Information Center
Office of Education (DHEW), Washington, DC.
Developed by a subject matter specialist, this suggested curriculum guide is intended to assist school administrators, advisory committees, supervisors, and teachers in planning and developing new programs or evaluating existing ones in agricultural equipment technology. The guide provides suggested course outlines, including examples of texts and…
30 CFR 33.21 - Modification of test equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Modification of test equipment. 33.21 Section 33.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL...
30 CFR 33.21 - Modification of test equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Modification of test equipment. 33.21 Section 33.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL...
30 CFR 33.21 - Modification of test equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Modification of test equipment. 33.21 Section 33.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL...
30 CFR 33.21 - Modification of test equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Modification of test equipment. 33.21 Section 33.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL...
30 CFR 33.21 - Modification of test equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Modification of test equipment. 33.21 Section 33.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL...
Introduction:
Paraffins are naturally-occurring components of crude oils, but often form solids within oil reservoirs and on oil production equipment when oil is harvested from hot subsurface temperatures to the cooler surface environments. Microbial t...
ERIC Educational Resources Information Center
Stroup, Karen Bruner; And Others
1991-01-01
Equipment to allow safe transportation of disabled children is reviewed. Such equipment includes infant car seats, child safety seats, safety vests, and accommodations for children in casts and/or braces. Five principles for evaluation and selection of safe seating options are given as are safety rules and information on standards and resources.…
33 CFR 155.2230 - Response plan development and evaluation criteria.
Code of Federal Regulations, 2010 CFR
2010-07-01
... extent practicable; and (2) Sources of the equipment and supplies necessary to contain, recover, and... and canals, inland, nearshore, and offshore areas 24 hrs N/A N/A Open ocean (plus travel time from... through contract or other approved means: (1) A salvage company with appropriate expertise and equipment...
2015-02-25
required. For example, RF transmitting equipment is tested for Hazards of Electromagnetic Radiation to Personnel ( HERP ) at EPG’s Electromagnetic...Environmental Effects EPG U.S. Army Electronic Proving Ground GFCI ground fault circuit interrupter GOTS Government off-the-shelf HERP
DOT National Transportation Integrated Search
2012-12-01
The objective of this project is to identify, evaluate and synthesize best practices that can be implemented to minimize the effects of deicer corrosion on DOT winter : vehicles and equipment, such as design improvements, maintenance practices, and t...
ERIC Educational Resources Information Center
Ewing, Molly
2015-01-01
The Educators Evaluating the Quality of Instructional Products (EQuIP) Rubric for science is a new tool for science educators that provides criteria by which to examine the alignment and overall quality of lessons and units with respect to the "Next Generation Science Standards" ("NGSS"). The rubric criteria are divided into…
10 CFR 603.540 - Acceptability of fully depreciated real property or equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Acceptability of fully depreciated real property or equipment. 603.540 Section 603.540 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS TECHNOLOGY INVESTMENT AGREEMENTS Pre-Award Business Evaluation Cost Sharing § 603.540 Acceptability of fully depreciated...
49 CFR 214.515 - Overhead covers for existing on-track roadway maintenance machines.
Code of Federal Regulations, 2010 CFR
2010-10-01
... previously equipped with overhead covers for the operator's position, defective covers shall be repaired, and missing covers shall be reinstalled, by March 28, 2005 and thereafter maintained in accordance with the... equipped with overhead covers for the operator's position, the employer shall evaluate the feasibility of...
30 CFR 254.42 - Exercises for your response personnel and equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Objectives met; and (5) Lessons learned. (e) All records of spill-response exercises must be maintained for... procedures or strategies. The Regional Supervisor may evaluate the results of the exercises and advise the owner or operator of any needed changes in response equipment, procedures, or strategies. (i) Compliance...
This document is the Environmental Technology Verification (ETV) Technology Specific Test Plan (TSTP) for evaluation of drinking water treatment equipment utilizing adsorptive media for synthetic organic chemical (SOC) removal. This TSTP is to be used within the structure provid...
The report gives results of demonstrations of technologies to prevent or control emissions of hazardous air pollutant (HAPs) and volatile organic compounds (VOCs) from processes with high solvent usage: (1) paint stripping using methylene chloride, (2) cleaning paint equipment wi...
78 FR 73085 - Mission Compatibility Evaluation Process
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-05
... daily operating hours or the number of days that equipment in the proposed structure would be in use... structure, operating characteristics, or the equipment in the proposed project. (2) Changing the location of... the DoD involve proposals for the construction of structures that may affect navigable air space...
Planning the School Food Service Facilities. Revised 1967.
ERIC Educational Resources Information Center
Utah State Board of Education, Salt Lake City.
Evaluations of food service equipment, kitchen design and food service facilities are comprehensively reviewed for those concerned with the planning and equipping of new school lunchrooms or the remodeling of existing facilities. Information is presented in the form of general guides adaptable to specific local situations and needs, and is…
SEABEE Pretest Results of the Joint Logistics-over-the-Shore (LOTS) Test and Evaluation Program.
1977-12-07
in the harbor. None of the equipment required extensive shoring. Some chocks and * wedges were placed on the equipment to increase its stability. P...incident. A subsequent examination revealed considerable structural damage to *the Peck & Hale tie-downs. Evidently one of the latching devices
A GUIDE FOR EQUIPPING INDUSTRIAL ARTS FACILITIES.
ERIC Educational Resources Information Center
American Industrial Arts Association, Washington, DC. Equipment Guide Committee.
SCHOOL ARCHITECTS, ADMINISTRATORS, PLANNERS, AND INDUSTRIAL ARTS SUPERVISORS AND TEACHERS MAY USE THIS GUIDE IN PLANNING, REVISING, AND EVALUATING FACILITIES. IN THE FIRST PART, HAND TOOLS, MACHINES, AND GENERAL EQUIPMENT ARE LISTED FOR (1) AUTO AND POWER MECHANICS, (2) CERAMICS, (3) DRAFTING, (4) ELECTRICITY-ELECTRONICS, (5) ELEMENTARY, (6)…
Uncertainty evaluation of dead zone of diagnostic ultrasound equipment
NASA Astrophysics Data System (ADS)
Souza, R. M.; Alvarenga, A. V.; Braz, D. S.; Petrella, L. I.; Costa-Felix, R. P. B.
2016-07-01
This paper presents a model for evaluating measurement uncertainty of a feature used in the assessment of ultrasound images: dead zone. The dead zone was measured by two technicians of the INMETRO's Laboratory of Ultrasound using a phantom and following the standard IEC/TS 61390. The uncertainty model was proposed based on the Guide to the Expression of Uncertainty in Measurement. For the tested equipment, results indicate a dead zone of 1.01 mm, and based on the proposed model, the expanded uncertainty was 0.17 mm. The proposed uncertainty model contributes as a novel way for metrological evaluation of diagnostic imaging by ultrasound.
Economic evaluation for use of advanced welding equipment
NASA Astrophysics Data System (ADS)
Petrov, P. Y.; Alekseev, I. V.; Kolesnik, E. A.
2017-10-01
Stable and sustainable predicted development of industrial enterprises within global competition is ensured by regular improvement of technologies and introduction of innovative technological equipment. In terms of comparative analysis of the various power supplies application in the welding production, the equality of relative resource efficiency of various equipment and specific economic effect has been calculated. The research showed that the costs per 1 meter are the smallest for semiautomatic welding in a protective gas environment using inverter power supplies, contributing to the economic benefit during its application.
Silicon production process evaluations
NASA Technical Reports Server (NTRS)
1982-01-01
Chemical engineering analyses involving the preliminary process design of a plant (1,000 metric tons/year capacity) to produce silicon via the technology under consideration were accomplished. Major activities in the chemical engineering analyses included base case conditions, reaction chemistry, process flowsheet, material balance, energy balance, property data, equipment design, major equipment list, production labor and forward for economic analysis. The process design package provided detailed data for raw materials, utilities, major process equipment and production labor requirements necessary for polysilicon production in each process.
Evaluating Long-Term Impacts of Soil-Mixing Source-Zone Treatment using Cryogenic Core Collection
2017-06-01
to (a) coring equipment freezing downhole, (b) freezing or binding of the core sample in barrel, and ( c ) running out of LN in the vicinity of sampling...encountered due to (a) coring equipment freezing downhole, (b) freezing or binding of the core sample in barrel, and ( c ) running out of LN in the...equipment freezing downhole, (b) freezing or binding of the core sample in barrel, and ( c ) running out of LN in the vicinity of sampling. Downhole
1991-01-01
Field 3. Training and Training Devices: a. Factory training b. Instructor and key personnel training c. New equipment training plan d. New equipment...12345678901234567990123456789012345678901234567890123456789 1. 0016 10 SUPPOR2AILITY ALTEIIIVE TRADE-OFF ANALISIS . 4. + 4" + 4. 4. 4 2. C1.0 111.0 N2.0 1.0 INITIATE
Aircraft Carrier Flight Deck Fire Fighting Tactics and Equipment Evaluation Tests
1987-02-26
pattern nozzles; 8. proper fire fighting techniques for possible titanium ignition in an F-14 crash (deleted later by direction of FLSC, being studied ...separately); 9. effect of full fire involvement of "ready for flight" aircraft (deleted later by direction of FLSC, being studied separately). The...to refine and identify specific hardware and tactical requirements generated from the studies conducted during the scoping tests; 3. concept
KATO, Maki; SHIMODAIRA, Yoshie; SATO, Takeshi; IIDA, Hiromi
2014-01-01
Abstract: Protecting children from injuries caused by fall accidents from playground equipment is important. Therefore, measures toward minimizing the risk of fall accident injuries are required. The risk of injury can be evaluated using ASTM F1292. In this test, G-max and the HIC are used to estimate the risk of injury. However, the measurement procedure is too complicated for application to a large number of installed equipment. F1292 requires simplified by reducing the number of phases, even with a small risk of loss in accuracy. With this in mind, this study proposes a shortened measurement procedure and a transformation equation to estimate the risk as same as F1292. As the result of experiments, it was revealed that G-max and the HIC values for both procedures linearly increase with drop height. The differences in outcomes between the regression equations of the standardized procedure and those of the shortened procedure can be used as a correction value. They can be added to the value measured by the shortened procedure. This suggests that the combination of the shortened procedure and transformation equation would be equivalent to F1292, with the advantage of being more easily and efficiently applied to the evaluation of installed playground equipment. PMID:25088989
Kato, Maki; Shimodaira, Yoshie; Sato, Takeshi; Iida, Hiromi
2014-01-01
Protecting children from injuries caused by fall accidents from playground equipment is important. Therefore, measures toward minimizing the risk of fall accident injuries are required. The risk of injury can be evaluated using ASTM F1292. In this test, G-max and the HIC are used to estimate the risk of injury. However, the measurement procedure is too complicated for application to a large number of installed equipment. F1292 requires simplified by reducing the number of phases, even with a small risk of loss in accuracy. With this in mind, this study proposes a shortened measurement procedure and a transformation equation to estimate the risk as same as F1292. As the result of experiments, it was revealed that G-max and the HIC values for both procedures linearly increase with drop height. The differences in outcomes between the regression equations of the standardized procedure and those of the shortened procedure can be used as a correction value. They can be added to the value measured by the shortened procedure. This suggests that the combination of the shortened procedure and transformation equation would be equivalent to F1292, with the advantage of being more easily and efficiently applied to the evaluation of installed playground equipment.
NASA Technical Reports Server (NTRS)
Billica, Roger; Krupa, Debra T.; Stonestreet, Robert; Kizzee, Victor D.
1991-01-01
The purpose is to investigate and demonstrate equipment and techniques proposed for minor surgery on Space Station Freedom (SSF). The objectives are: (1) to test and evaluate methods of surgical instrument packaging and deployment; (2) to test and evaluate methods of surgical site preparation and draping; (3) to evaluate techniques of sterile procedure and maintaining sterile field; (4) to evaluate methods of trash management during medical/surgical procedures; and (4) to gain experience in techniques for performing surgery in microgravity. A KC-135 parabolic flight test was performed on March 30, 1990 with the goal of investigating and demonstrating surgical equipment and techniques under consideration for use on SSF. The flight followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola.
ERIC Educational Resources Information Center
Yu, Chwo-Ming Joseph; Guan, Jyh-Liang; Yang, Kuo-Pin; Chiao, Yu-Ching
2005-01-01
This exploratory study addresses two issues: (1) how firms select applicants for positions in international management and, subsequently, evaluate the performance of international business education in Taiwan; and (2) what the important skills for international management professionals are, and how well university graduates are equipped with these…
Results from previous testing of this refrigerator/freezer (R/F) using a 750 Btu/hr compressor and several zeotrophic mixtures revealed a performance enhancement up to 16 percent above that of HFC-134a. In the study presented in this paper, the Lorenz-Meutzner (LM) R/F equipped ...
"Aprons are for Girls": Promoting Equity in Early Childhood Environments.
ERIC Educational Resources Information Center
Mullis, Ann K.; Martin, Ruth E.
1984-01-01
A 1982-83 study evaluating the level of sex equity in early childhood settings found that, while the areas of teaching behaviors and child awareness were strong, the areas of center/community, facilities and equipment, and career awareness need improvement in terms of encouraging sex equity and eliminating stereotypes. (SK)
Cost, production and effectiveness of masticated fireline.
Elizabeth Dodson; Dana Mitchell
2016-01-01
Fire managers are continuously looking for improved methods to construct fireline with minimal resource damage. One option for fireline construction that has so far received limited attention is the use of mastication equipment. This study evaluated a masticating disk mounted on a self-leveling feller- buncher for the cost, speed, and adherence to fireline...
Science Library of Test Items. Volume Four: Practical Testing Guide.
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test items collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, the guide gives a wide range of questions and activities for the manipulation of scientific equipment to allow assessment of students' practical laboratory skills. Instructions are given to make norm-referenced or…
Physicality and Language Learning
ERIC Educational Resources Information Center
Park, Jaeuk; Seedhouse, Paul; Seedhouse, Rob; Kiaer, Jieun
2016-01-01
The study draws on the digital technology which allows users to be able to learn both linguistic and non-linguistic skills at the same time. Activity recognition as well as wireless sensor technology, similar to a Nintendo Wii, is embedded or attached to the equipment and ingredients, allowing users to detect and evaluate progress as they carry…
48 CFR 227.7107-2 - Contracts for construction supplies and research and development work.
Code of Federal Regulations, 2010 CFR
2010-10-01
... supplies and research and development work. 227.7107-2 Section 227.7107-2 Federal Acquisition Regulations... research and development work. Use the provisions and clauses required by 227-7103-6 and 227.7203-6 when..., or research work, or test and evaluation studies of structures, equipment, processes, or materials...
Simulation technology used for risky assessment in deep exploration project in China
NASA Astrophysics Data System (ADS)
jiao, J.; Huang, D.; Liu, J.
2013-12-01
Deep exploration has been carried out in China for five years in which various heavy duty instruments and equipments are employed for gravity, magnetic, seismic and electromagnetic data prospecting as well as ultra deep drilling rig established for obtaining deep samples, and so on. The deep exploration is a large and complex system engineering crossing multiple subjects with great investment. It is necessary to employ advanced technical means technology for verification, appraisal, and optimization of geographical prospecting equipment development. To reduce risk of the application and exploration, efficient and allegeable management concept and skills have to be enhanced in order to consolidate management measure and workflow to benefit the ambitious project. Therefore, evidence, prediction, evaluation and related decision strategies have to be taken into accouter simultaneously to meet practical scientific requests and technique limits and extendable attempts. Simulation technique is then proposed as a tool that can be used to carry out dynamic test on actual or imagined system. In practice, it is necessary to combine the simulation technique with the instruments and equipment to accomplish R&D tasks. In this paper, simulation technique is introduced into the R&D process of heavy-duty equipment and high-end engineering project technology. Based on the information provided by a drilling group recently, a digital model is constructed by combination of geographical data, 3d visualization, database management, and visual reality technologies together. It result in push ahead a R&D strategy, in which data processing , instrument application, expected result and uncertainty, and even operation workflow effect environment atmosphere are simulated systematically or simultaneously, in order to obtain an optimal consequence as well as equipment updating strategy. The simulation technology is able to adjust, verify, appraise and optimize the primary plan due to changing in the real world or process, which can provide new insight to the equipment to meet requests from application and construction process and facilitates by means of direct perception and understanding of installation, debugging and experimental process of key equipment for deep exploration. Finally, the objective of project cost conservation and risk reduction can be reasonably approached. Risk assessment can be used to quantitatively evaluate the possible degree of the impact. During the research and development stage, information from the installation, debugging and simulation demonstration of the experiment process of the key instrument and equipment are used to evaluate the fatigue and safety of the device. It needs fully understanding the controllable and uncontrollable risk factors during the process, and then adjusting and improving the unsafe risk factors in the risk assessment and prediction. With combination with professional Geo software to process and interpret the environment to obtain evaluation parameters, simulation modeling is more likely close to exploration target which need more details of evaluations. From micro and macro comprehensive angles to safety and risk assessment can be achieved to satisfy the purpose of reducing the risk of equipment development, and to avoid unnecessary loss on the way of the development.
Evaluating the cost of one telehealth application connecting an acute and long-term care setting.
Specht, J K; Wakefield, B; Flanagan, J
2001-01-01
This article describes a study of the costs of a pilot telemedicine chronic wound consultation clinic. Cost minimization analysis is the technique used to examine the costs of the clinic. The components of cost analysis include the fixed costs of personnel and equipment and the indirect costs of circuit and line charges. Cost avoidance is also examined. Cost avoidance evaluates what costs were avoided by the use of the telemedicine clinic. Additionally, the cost perspectives of the consulting agency, the referring agency, and the patient are examined. The average cost of a chronic wound consultation was $136.16 (acute care perspective). Costs of a traditional face-to-face consultation, if the residents were transported to the acute care facility would be $246.28. Fifteen telehealth consultations per month were used to determine per consultation costs for line charges and depreciation/maintenance costs. In this pilot study, a cost savings was realized and patients benefited. Increased volume will help to offset the cost of the equipment depreciation and maintenance and make telehealth chronic wound consultations more cost effective.
Electrochemical Evaluation of Alloys for Spaceport Design
NASA Astrophysics Data System (ADS)
Calle, Luz Marina; MacDowell, Louis G.; Vinje, Rubiela D.
2003-01-01
Corrosion studies began at the Kennedy Space Center (KSC) in 1966 during the Gemini/Apollo Programs with the evaluation of long-term protective coatings for the corrosion protection of carbon steel. NASA's KSC Beach Corrosion Test Site, which was established at that time, has been documented by the American Society of Materials (ASM) as one of the most corrosive naturally occurring environments in the world. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pad were rendered even more severe by the acidic exhaust from the solid rocker boosters. In the years that followed, numerous studies have identified materials, coatings, and maintenance procedures for launch hardware and equipment exposed to the highly corrosive environment at the launch pad. The Corrosion Laboratory was established at KSC in 1985 and was outfitted with state-of-the-art electrochemistry equipment to conduct research and materials characterization in many different corrosive environments. This paper will describe the application of electrochemistry in combination with atmospheric exposure to the selection of alloys in a spaceport environment.
Crozer-Chester Medical Center Burn Research Projects
2008-07-17
Autogenous Skin Donor Sites” This study will compare the performance of an agreed upon dressing to the normal standard of care (Xeroform). Patients who...and training of research staff, purchasing equipment) (Year 1, Quarter 1) b. Enroll 15 study subjects and collect data (Year 1, Quarters 2-4) c...Enroll 5 study subjects and collect data (Year 2, Quarter 1) Study 2, Protocol Title: “Evaluation of Aquacel Ag for Autogenous Skin Donor Sites
Etier, Brian E; Norte, Grant E; Gleason, Megan M; Richter, Dustin L; Pugh, Kelli F; Thomson, Keith B; Slater, Lindsay V; Hart, Joe M; Brockmeier, Stephen F; Diduch, David R
2017-12-01
The National Athletic Trainers' Association (NATA) advocates for cervical spine immobilization on a rigid board or vacuum splint and for removal of athletic equipment before transfer to an emergency medical facility. To (1) compare triplanar cervical spine motion using motion capture between a traditional rigid spine board and a full-body vacuum splint in equipped and unequipped athletes, (2) assess cervical spine motion during the removal of a football helmet and shoulder pads, and (3) evaluate the effect of body mass on cervical spine motion. Controlled laboratory study. Twenty healthy male participants volunteered for this study to examine the influence of immobilization type and presence of equipment on triplanar angular cervical spine motion. Three-dimensional cervical spine kinematics was measured using an electromagnetic motion analysis system. Independent variables included testing condition (static lift and hold, 30° tilt, transfer, equipment removal), immobilization type (rigid, vacuum-mattress), and equipment (on, off). Peak sagittal-, frontal-, and transverse-plane angular motions were the primary outcome measures of interest. Subjective ratings of comfort and security did not differ between immobilization types ( P > .05). Motion between the rigid board and vacuum splint did not differ by more than 2° under any testing condition, either with or without equipment. In removing equipment, the mean peak motion ranged from 12.5° to 14.0° for the rigid spine board and from 11.4° to 15.4° for the vacuum-mattress splint, and more transverse-plane motion occurred when using the vacuum-mattress splint compared with the rigid spine board (mean difference, 0.14 deg/s [95% CI, 0.05-0.23 deg/s]; P = .002). In patients weighing more than 250 lb, the rigid board provided less motion in the frontal plane ( P = .027) and sagittal plane ( P = .030) during the tilt condition and transfer condition, respectively. The current study confirms similar motion in the vacuum-mattress splint compared with the rigid backboard in varying sized equipped or nonequipped athletes. Cervical spine motion occurs when removing a football helmet and shoulder pads, at an unknown risk to the injured athlete. In athletes who weighed more than 250 lb, immobilization with the rigid board helped to reduce cervical spine motion. Athletic trainers and team physicians should consider immobilization of athletes who weigh more than 250 lb with a rigid board.
Diagnostic Assessment of Troubleshooting Skill in an Intelligent Tutoring System
1994-03-01
the information that can be provided from studying gauges and indicators and conventional test equipment procedures. Experts are particularly adept at...uses the results of the strategy and action evaluator to update the student profile, represented as a network, using the ERGO ( Noetic Systems, 1993...1990). Individualized tutoring using an intelligent fuzzy temporal relational database. International Tournal of Man-Machine Studies . & 409-429. . 34
An observational study of protective equipment use among in-line skaters
Warda, L.; Harlos, S.; Klassen, T.; Moffatt, M.; Buchan, N.; Koop, V.
1998-01-01
Objectives—To describe the patterns of protective equipment use by in-line skaters in Winnipeg, Manitoba and nearby rural communities. Methods—In-line skaters were observed for three months in 1996 at 190 urban and 30 rural sites selected using a formal sampling scheme. Age, gender, protective equipment use, skating companions, correct helmet use, and use of headphones were recorded. Results—Altogether 123 in-line skaters were observed at 61 sites, including one rural site. No skaters were observed at the remaining sites. There were 37 adults and 86 children; 56% were male. Helmet use was 12.2% (95% confidence interval (CI ) = 6.4% to 18.0%), wrist guard use was 16.3% (95% CI = 9.7% to 22.8%), knee pad use was 9.8% (95% CI = 5.2% to 16.4%), and elbow pad use was 7.3% (95% CI = 3.4% to 13.4%). Children were more likely to wear a helmet than teens 12–19 years of age (relative risk (RR) = 30, 95% CI = 4.01 to 225). Adults were more likely to wear wrist guards than children (RR = 4.32, 95% CI = 1.87 to 9.94). No gender differences were found. Incorrect helmet use was documented in four skaters; three skaters were wearing headphones. Conclusions—Low rates of protective equipment use were documented in our region, significantly lower than those reported in the literature. Barriers to equipment use are not known, and should be examined by further study. In-line skating safety programs should be developed, promoted, and evaluated. Teens should be targeted for future preventive efforts. PMID:9788090
New methodology to baseline and match AME polysilicon etcher using advanced diagnostic tools
NASA Astrophysics Data System (ADS)
Poppe, James; Shipman, John; Reinhardt, Barbara E.; Roussel, Myriam; Hedgecock, Raymond; Fonda, Arturo
1999-09-01
As process controls tighten in the semiconductor industry, the need to understand the variables that determine system performance become more important. For plasma etch systems, process success depends on the control of key parameters such as: vacuum integrity, pressure, gas flows, and RF power. It is imperative to baseline, monitor, and control these variables. This paper presents an overview of the methods and tools used by Motorola BMC fabrication facility to characterize an Applied Materials polysilicon etcher. Tool performance data obtained from our traditional measurement techniques are limited in their scope and do not provide a complete picture of the ultimate tool performance. Presently the BMC traditional characterization tools provide a snapshot of the static operation of the equipment under test (EUT); however, complete evaluation of the dynamic performance cannot be monitored without the aid of specialized diagnostic equipment. To provide us with a complete system baseline evaluation of the polysilicon etcher, three diagnostic tools were utilized: Lucas Labs Vacuum Diagnostic System, Residual Gas Analyzer, and the ENI Voltage/Impedance Probe. The diagnostic methodology used to baseline and match key parameters of qualified production equipment has had an immense impact on other equipment characterization in the facility. It has resulted in reduced cycle time for new equipment introduction as well.
Apparel for Cleaner Clean Rooms
NASA Technical Reports Server (NTRS)
1983-01-01
In the 1960s NASA pioneered contamination control technology, providing a base from which aerospace contractors could develop control measures. NASA conducted special courses for clean room technicians and supervisors, and published a series of handbooks with input from various NASA field centers. These handbooks extended aerospace experience to the medical, pharmaceutical, electronics, and other industries where extreme cleanliness is important. American Hospital Supply Company (AHSC) felt that high technology products with increasingly stringent operating requirements in aerospace, electronics, pharmaceuticals and medical equipment manufacturing demanded improvement in contamination control techniques. After studying the NASA handbooks and visiting NASA facilities, the wealth of information gathered resulted in Micro-clean non-woven garments and testing equipment and procedures for evaluating effectiveness.
Shuttle spacelab simulation using a Lear jet aircraft: Mission no. 3 (ASSESS program)
NASA Technical Reports Server (NTRS)
Reller, J. O., Jr.; Neel, C. B.; Mason, R. H.
1974-01-01
The third ASSESS mission using a Lear Jet aircraft conducted to continue the study of scientific experiment operations in a simulated Spacelab environment. Prior to the mission, research planning and equipment preparation were observed and documented. A flight readiness review for the experiment was conducted. Nine of the ten scheduled flights were completed during simulation mission and all major science objectives were accomplished. The equipment was well qualified for flight and gave little trouble; telescope malfunctions occurred early in the mission and were corrected. Both real-time and post-observation data evaluation were used to assess research progress and to plan subsequent flight observations for maximum effectiveness.
Waste heat recovery from adiabatic diesel engines by exhaust-driven Brayton cycles
NASA Technical Reports Server (NTRS)
Khalifa, H. E.
1983-01-01
An evaluation of Bryton Bottoming Systems (BBS) as waste heat recovery devices for future adiabatic diesel engines in heavy duty trucks is presented. Parametric studies were performed to evaluate the influence of external and internal design parameters on BBS performance. Conceptual design and trade-off studies were undertaken to estimate the optimum configuration, size, and cost of major hardware components. The potential annual fuel savings of long-haul trucks equipped with BBS were estimated. The addition of a BBS to a turbocharged, nonaftercooled adiabatic engine would improve fuel economy by as much as 12%. In comparison with an aftercooled, turbocompound engine, the BBS-equipped turbocharged engine would offer a 4.4% fuel economy advantage. If installed in tandem with an aftercooled turbocompound engine, the BBS could effect a 7.2% fuel economy improvement. The cost of a mass-produced 38 Bhp BBS is estimated at about $6460 or 170/Bhp. Technical and economic barriers that hinder the commercial introduction of bottoming systems were identified. Related studies in the area of waste heat recovery from adiabatic diesel engines and NASA-CR-168255 (Steam Rankine) and CR-168256 (Organic Rankine).
NASA Astrophysics Data System (ADS)
Alviz Meza, A.; Kafarov, V.; Y Peña Ballesteros, D.
2017-12-01
Corrosion studies are key element that ensure the correct functioning of equipment in the industrial sector. The oxidation phenomena were evaluated, taking as a case study steel ASTM A335 P91 (P91), a steel of typical use in equipment that work at high temperatures. Five (5) exposure times were selected for the experimental development: 1, 20, 50, 100 and 200h; as well as four (4) analysis temperatures: 450, 550, 650 and 750°C. Through the metallographic analysis was possible to evidence the presence of multiple carbide precipitates and a ferritic structure, after all the temperatures tested. On the other hand, the analysis of hardness and microhardness showed an increase for all the evaluated temperatures. These increases were mainly related to the precipitation of carbides in the coupons of P91. Regarding to the chemical analysis, it was possible to conclude that after 200h of experimentation in each temperature, a layer of duplex oxide, composed mainly of hematite, magnetite and spinel iron-chromium, was formed in the O2/H2O atmosphere. Finally, the kinetic study demonstrated that the oxide layer formed on each coupon of P91 was of protective character.
Occupational skin diseases and prevention among sanitation workers in China.
Yan, Yuehua; Wang, Xinggang; Wu, Jianbo; Xu, Li
2015-09-01
Little research has been focused on the health status or the occupational protection awareness of sanitation workers. The policy recommendations on the occupational safety and health of sanitation workers based on the scientific research are also insufficient in developing countries like China. To study the incidence of dermatoses and the relevance with occupational exposure, protection awareness and protective measures among sanitation workers for better management and protection of the sanitation workers. 273 sanitation workers and 113 administrative staff from 11 streets of Wuhan were recruited. Dermatological problems were evaluated and recorded by physical examination. Occupational exposure, protection awareness, the use of protective equipments and personal history of skin disease were assessed by questionnaires. Compared with administrative staff, sanitation workers had much more occupational dermatological problems and had a much higher rate of harmful ultraviolet ray exposure. Young sanitation workers were more aware of occupational self-protection and a relatively higher rate of them using protective equipments compared with old ones. Exposure to multiple health hazards and the poor use of protective equipments are related to skin diseases in sanitation workers. Prejob training of self-protection and the use of protective equipments are recommended.
KO, Jiunn-Liang; CHENG, Yu-Jung; LIU, Guan-Cen; HSIN, I-Lun; CHEN, Hsiu-Ling
2017-01-01
The welding is the major working process in fitness equipment manufacturing industry, and International Agency for Research on Cancer has classified welding fumes as possibly carcinogenic to humans (Group 2B). The present study aimed to evaluate associations between the occupational exposure of metals and oxidative damage and telomere length shortening in workers involved in the manufacture of fitness equipment. The blood metal concentrations were monitored and malondialdehyde (MDA), alkaline Comet assay was determined as oxidative damage in 117 workers from two representative fitness equipment manufacturing plants. MDA levels varied according to workers’ roles at the manufacturing plants, and showed a trend as cutting>painting>welding>administration workers. Welders had marginally shorter average telomere lengths than the administrative workers (p=0.058). Cr and Mn levels were significantly greater in welders than they were in administrative workers. There were significantly positive correlations between MDA and Cr and Mn levels, the major components of welding fume. However, the association would be eliminated if co-metals exposure were considered simultaneously. In future, telomere length and MDA might be potential biomarkers for predicting cardiovascular disease in co-metals exposed workers. PMID:28420806
Helmets and Mouth Guards: The Role of Personal Equipment in Preventing Sport-Related Concussions
Daneshvar, Daniel H.; Baugh, Christine M.; Nowinski, Christopher J.; McKee, Ann C.; Stern, Robert A.; Cantu, Robert C.
2010-01-01
Every year, millions of athletes in the United States experience concussions. With athletes at all levels of play getting bigger, faster, and stronger, it has been suggested that newer technologies may provide an opportunity to reduce the risk and severity of these all too frequent injuries. Although helmets have been shown to decrease the rate of catastrophic head injuries, and mouth guards have decreased the risk of dental and oral injuries, the protective effect of helmets and mouth guards on concussions has not been conclusively demonstrated. In this review, the current literature pertaining to the effect that equipment has on concussions is evaluated. Understanding the role that this equipment plays in preventing concussions is complicated by many factors, such as selection bias in non-randomized studies, variations in playing style, and risk compensation in sports with mandatory protective equipment. At this point, there is little evidence supporting the use of specific helmets or mouth guards to prevent concussions outside of specific sports such as cycling, skiing, and snowboarding. Improving coach and player education about proper concussion management, encouraging neck strengthening exercises, and minimizing high-risk impacts may provide a more fruitful avenue to reduce concussions in sports. PMID:21074089
A Study on Performance and Safety Tests of Electrosurgical Equipment
Tavakoli Golpaygani, A.; Movahedi, M.M.; Reza, M.
2016-01-01
Introduction: Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient’s safety and management of the risks associated with the use of high and low frequency electrical currents on human body. Material and Methods: The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public) was evaluated in one of the provinces of Iran according to international and national standards. Results: The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Conclusion: Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment. PMID:27853725
NASA Technical Reports Server (NTRS)
Rey, Charles A.
1991-01-01
The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.
NASA Astrophysics Data System (ADS)
Rey, Charles A.
1991-03-01
The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.
Project FIRES. Volume 1: Program Overview and Summary, Phase 1B
NASA Technical Reports Server (NTRS)
Abeles, F. J.
1980-01-01
Overall performance requirements and evaluation methods for firefighters protective equipment were established and published as the Protective Ensemble Performance Standards (PEPS). Current firefighters protective equipment was tested and evaluated against the PEPS requirements, and the preliminary design of a prototype protective ensemble was performed. In phase 1B, the design of the prototype ensemble was finalized. Prototype ensembles were fabricated and then subjected to a series of qualification tests which were based upon the PEPS requirements. Engineering drawings and purchase specifications were prepared for the new protective ensemble.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurtz, J.; Sprik, S.; Ramsden, T.
2013-11-01
This webinar presentation to the UK Hydrogen and Fuel Cell Association summarizes how the U.S. Department of Energy is enabling early fuel cell markets; describes objectives of the National Fuel Cell Technology Evaluation Center; and presents performance status of fuel cell material handling equipment.
10 CFR 72.154 - Control of purchased material, equipment, and services.
Code of Federal Regulations, 2012 CFR
2012-01-01
... CLASS C WASTE Quality Assurance § 72.154 Control of purchased material, equipment, and services. (a) The..., as appropriate, for source evaluation and selection, objective evidence of quality furnished by the... shall retain or have available this documentary evidence for the life of the ISFSI, MRS, or spent fuel...
10 CFR 72.154 - Control of purchased material, equipment, and services.
Code of Federal Regulations, 2014 CFR
2014-01-01
... CLASS C WASTE Quality Assurance § 72.154 Control of purchased material, equipment, and services. (a) The..., as appropriate, for source evaluation and selection, objective evidence of quality furnished by the... shall retain or have available this documentary evidence for the life of the ISFSI, MRS, or spent fuel...
10 CFR 72.154 - Control of purchased material, equipment, and services.
Code of Federal Regulations, 2011 CFR
2011-01-01
... CLASS C WASTE Quality Assurance § 72.154 Control of purchased material, equipment, and services. (a) The..., as appropriate, for source evaluation and selection, objective evidence of quality furnished by the... shall retain or have available this documentary evidence for the life of the ISFSI, MRS, or spent fuel...
10 CFR 72.154 - Control of purchased material, equipment, and services.
Code of Federal Regulations, 2013 CFR
2013-01-01
... CLASS C WASTE Quality Assurance § 72.154 Control of purchased material, equipment, and services. (a) The..., as appropriate, for source evaluation and selection, objective evidence of quality furnished by the... shall retain or have available this documentary evidence for the life of the ISFSI, MRS, or spent fuel...
10 CFR 72.154 - Control of purchased material, equipment, and services.
Code of Federal Regulations, 2010 CFR
2010-01-01
... CLASS C WASTE Quality Assurance § 72.154 Control of purchased material, equipment, and services. (a) The..., as appropriate, for source evaluation and selection, objective evidence of quality furnished by the... shall retain or have available this documentary evidence for the life of the ISFSI, MRS, or spent fuel...
Stand, Harvest, and Equipment Interactions in Simulated Harvesting Prescriptions
Jingxin Wang; W. Dale Greene; Bryce J. Stokes
1998-01-01
We evaluated potential interactions of stand type, harvesting method, and equipment in an experiment using interactive simulation. We examined three felling methods (chain saw, feller-buncher, harvester) and two extraction methods (grapple skidder and forwarder) performing clearcuts, sheltenvood cuts, and single-tree selection cuts in both an uneven-aged natural stand...
Equipment
The Grafton and Boston Tufts laboratories are impressively equipped to perform this work. They were able to work with the company Haemonetics to make a new automated centrifuge, with remote control and offline capabilities. Sadly, while...
30 CFR 18.99 - Notice of approval or disapproval; letters of approval and approval plates.
Code of Federal Regulations, 2010 CFR
2010-07-01
... approval or disapproval of the machine. (a) If the qualified electrical representative recommends field..., DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Field Approval of Electrically Operated Mining Equipment § 18.99 Notice of approval or...
30 CFR 18.99 - Notice of approval or disapproval; letters of approval and approval plates.
Code of Federal Regulations, 2011 CFR
2011-07-01
... approval or disapproval of the machine. (a) If the qualified electrical representative recommends field..., DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Field Approval of Electrically Operated Mining Equipment § 18.99 Notice of approval or...
30 CFR 250.518 - Tubing and wellhead equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... otherwise suitable for its intended use. (b) In the event of prolonged operations such as milling, fishing... otherwise evaluated every 30 days and the results submitted to the District Manager. (c) When the tree is... . . . you must equip . . . so you can monitor . . . (1) fixed platform wells, the wellhead, all annuli (A, B...
30 CFR 250.517 - Tubing and wellhead equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... otherwise suitable for its intended use. (b) In the event of prolonged operations such as milling, fishing... otherwise evaluated every 30 days and the results submitted to the District Manager. (c) When the tree is... . . . you must equip . . . so you can monitor . . . (1) fixed platform wells, the wellhead, all annuli (A, B...
30 CFR 250.518 - Tubing and wellhead equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... otherwise suitable for its intended use. (b) In the event of prolonged operations such as milling, fishing... otherwise evaluated every 30 days and the results submitted to the District Manager. (c) When the tree is... . . . you must equip . . . so you can monitor . . . (1) fixed platform wells, the wellhead, all annuli (A, B...
Typical uses of NASTRAN in a petrochemical industry
NASA Technical Reports Server (NTRS)
Winter, J. R.
1978-01-01
NASTRAN was principally used to perform failure analysis and redesign process equipment. It was also employed in the evaluation of vendor designs and proposed design modifications to existing process equipment. Stress analysis of forced draft fans, distillation trays, metal stacks, jacketed pipes, heat exchangers, large centrifugal fans, and agitator support structures are described.
ERIC Educational Resources Information Center
Finn, James D.; Weintraub, Royd
The Medical Information Project (MIP) purpose to select the right type of audiovisual equipment for communicating new medical information to general practitioners of medicine was hampered by numerous difficulties. There is a lack of uniformity and standardization in audiovisual equipment that amounts to chaos. There is no evaluative literature on…
DOT National Transportation Integrated Search
2009-01-13
This research effort was to investigate whether spatial locating equipment or Global Positioning System (GPS) equipment mounted on Connecticut Department of Transportation (ConnDOT) ARAN vans could be used to locate areas of distressed pavement. It w...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-30
.... Evaluation and Testing CSA Group with the manufacturer's assistance prepares a motor control list...-0053] Energy Efficiency Program for Industrial Equipment: Petition of CSA Group for Classification as a...: This notice announces receipt of a petition from CSA Group (CSA) seeking classification as a nationally...
Herbaut, Alexis; Simoneau-Buessinger, Emilie; Barbier, Franck; Cannard, Francis; Guéguen, Nils
2016-10-01
Footwear comfort is essential and pressure distribution on the foot was shown as a relevant objective measurement to assess it. However, asperities on the foot sides, especially the metatarsals and the instep, make its evaluation difficult with available equipment. Thus, a sock equipped with textile pressure sensors was designed. Results from the mechanical tests showed a high linearity of the sensor response under incremental loadings and allowed to determine the regression equation to convert voltage values into pressure measurements. The sensor response was also highly repeatable and the creep under constant loading was low. Pressure measurements on human feet associated with a perception questionnaire exhibited that significant relationships existed between pressure and comfort perceived on the first, the third and the fifth metatarsals and top of the instep. Practitioner Summary: A sock equipped with textile sensors was validated for measuring the pressure on the foot top, medial and lateral sides to evaluate footwear comfort. This device may be relevant to help individuals with low sensitivity, such as children, elderly or neuropathic, to choose the shoes that fit the best.
Advances in diagnostic ultrasonography.
Reef, V B
1991-08-01
A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.